The discovery and early understanding of leukemia.
Kampen, Kim R
2012-01-01
The early history of leukemia reaches back 200 years. In 1811, Peter Cullen defined a case of splenitis acutus with unexplainable milky blood. Alfred Velpeau defined the leukemia associated symptoms, and observed pus in the blood vessels (1825). Alfred Donné detected a maturation arrest of the white blood cells (1844). John Bennett named the disease leucocythemia, based on the microscopic accumulation of purulent leucocytes (1845). That same year, Rudolf Virchow defined a reversed white and red blood cell balance. He introduced the disease as leukämie in 1847. Henry Fuller performed the first microscopic diagnose of a leukemic patient during life (1846). This gradual process brought us towards our current understanding of this complex disease. Copyright © 2011 Elsevier Ltd. All rights reserved.
Lei, Kin Fong; Chen, Kuan-Hao; Tsui, Po-Hsiang; Tsang, Ngan-Ming
2013-01-01
Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity. PMID:24116099
The optical method for investigation of the peritonitis progressing process
NASA Astrophysics Data System (ADS)
Guminetskiy, S. H.; Ushenko, O. G.; Polyanskiy, I. P.; Motrych, A. V.; Grynchuk, F. V.
2008-05-01
There have been given the results of the spectrophotometric examination of the dogs' and rats' venous and whole blood plasma taken in the process of the peritonitis progressing within the spectral interval λ = 220 - 320 nm (for plasma) and λ = 350 - 610 nm (for the whole blood). It has been defined that D-optical density values in the field of the long-waved maximum of plasma absorption intensity of the venous blood at λ = 280 nm depend upon the intensity of the inflammatory process and also upon the circumstances against the background of which it started to progress. It was found out that the dynamics of D= values changes for λ = 540 (or 570) nm in the process of the peritonitis progressing in case of the whole blood taken from a portal vein is a mirror symmetrical if to compare to the same dynamics for the blood from cava inferior. The defined conformities with regularities may have a diagnostic meaning. It was also found out that the biggest influence upon the dynamics of D-values at λ = 280nm of the venous blood plasma has the content of the circulating immune complexes, necrosis factor of α-tumors and interleukin - 2, the changes of which explain for almost on 100% the distribution of the optical density parameters and what proves a possible immunologic explanation of its changes.
Device and method for automated separation of a sample of whole blood into aliquots
Burtis, Carl A.; Johnson, Wayne F.
1989-01-01
A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.
Autotransfusion in cardiac surgery.
Cross, M H
2001-09-01
There are a number of problems with allogeneic blood transfusion. Some of these problems are defined and can be quantified, such as the problem of rising cost or the risk of viral infection, but some of the problems are not well defined and it is only outcome data that point to allogeneic blood transfusion contributing to patient mortality and morbidity. Autotransfusion includes any technique in which the patient's own blood is collected, processed and stored, followed by reinfusion when circumstances dictate. In the perioperative period of cardiac surgery, a number of techniques are recognized as useful in this context. Preoperative autologous donation, with or without erythropoietin supplementation, intraoperative acute normovolaemic haemodilution, intraoperative cell salvage, postoperative cell salvage (reinfusion of shed mediastinal blood) and platelet rich plasmapheresis are all techniques which are used with more or less enthusiasm to reduce the need for an allogeneic blood transfusion. Modification of the priming technique of the cardiopulmonary bypass circuit using an autologous blood prime is included in this review even though it does not fall strictly within the definition of autotransfusion. Although autotransfusion is not the answer to every problem, there is no doubt that it should play a significant part in the strategy of blood conservation.
Grazzini, Giuliano; Ceccarelli, Anna; Calteri, Deanna; Catalano, Liviana; Calizzani, Gabriele; Cicchetti, Americo
2013-01-01
Background In Italy, the financial reimbursement for labile blood components exchanged between Regions is regulated by national tariffs defined in 1991 and updated in 1993–2003. Over the last five years, the need for establishing standard costs of healthcare services has arisen critically. In this perspective, the present study is aimed at defining both the costs of production of blood components and the related prices, as well as the prices of plasma-derived medicinal products obtained by national plasma, to be used for interregional financial reimbursement. Materials and methods In order to analyse the costs of production of blood components, 12 out 318 blood establishments were selected in 8 Italian Regions. For each step of the production process, driving costs were identified and production costs were. To define the costs of plasma-derived medicinal products obtained by national plasma, industrial costs currently sustained by National Health Service for contract fractionation were taken into account. Results The production costs of plasma-derived medicinal products obtained from national plasma showed a huge variability among blood establishments, which was much lower after standardization. The new suggested plasma tariffs were quite similar to those currently in force. Comparing the overall costs theoretically sustained by the National Health Service for plasma-derived medicinal products obtained from national plasma to current commercial costs, demonstrates that the national blood system could gain a 10% cost saving if it were able to produce plasma for fractionation within the standard costs defined in this study. Discussion Achieving national self-sufficiency through the production of plasma-derived medicinal products from national plasma, is a strategic goal of the National Health Service which must comply not only with quality, safety and availability requirements but also with the increasingly pressing need for economic sustainability. PMID:24333307
Grazzini, Giuliano; Ceccarelli, Anna; Calteri, Deanna; Catalano, Liviana; Calizzani, Gabriele; Cicchetti, Americo
2013-09-01
In Italy, the financial reimbursement for labile blood components exchanged between Regions is regulated by national tariffs defined in 1991 and updated in 1993-2003. Over the last five years, the need for establishing standard costs of healthcare services has arisen critically. In this perspective, the present study is aimed at defining both the costs of production of blood components and the related prices, as well as the prices of plasma-derived medicinal products obtained by national plasma, to be used for interregional financial reimbursement. In order to analyse the costs of production of blood components, 12 out 318 blood establishments were selected in 8 Italian Regions. For each step of the production process, driving costs were identified and production costs were. To define the costs of plasma-derived medicinal products obtained by national plasma, industrial costs currently sustained by National Health Service for contract fractionation were taken into account. The production costs of plasma-derived medicinal products obtained from national plasma showed a huge variability among blood establishments, which was much lower after standardization. The new suggested plasma tariffs were quite similar to those currently in force. Comparing the overall costs theoretically sustained by the National Health Service for plasma-derived medicinal products obtained from national plasma to current commercial costs, demonstrates that the national blood system could gain a 10% cost saving if it were able to produce plasma for fractionation within the standard costs defined in this study. Achieving national self-sufficiency through the production of plasma-derived medicinal products from national plasma, is a strategic goal of the National Health Service which must comply not only with quality, safety and availability requirements but also with the increasingly pressing need for economic sustainability.
Baek, Jin Hyen; D'Agnillo, Felice; Vallelian, Florence; Pereira, Claudia P; Williams, Matthew C; Jia, Yiping; Schaer, Dominik J; Buehler, Paul W
2012-04-01
Massive transfusion of blood can lead to clinical complications, including multiorgan dysfunction and even death. Such severe clinical outcomes have been associated with longer red blood cell (rbc) storage times. Collectively referred to as the rbc storage lesion, rbc storage results in multiple biochemical changes that impact intracellular processes as well as membrane and cytoskeletal properties, resulting in cellular injury in vitro. However, how the rbc storage lesion triggers pathophysiology in vivo remains poorly defined. In this study, we developed a guinea pig transfusion model with blood stored under standard blood banking conditions for 2 (new), 21 (intermediate), or 28 days (old blood). Transfusion with old but not new blood led to intravascular hemolysis, acute hypertension, vascular injury, and kidney dysfunction associated with pathophysiology driven by hemoglobin (Hb). These adverse effects were dramatically attenuated when the high-affinity Hb scavenger haptoglobin (Hp) was administered at the time of transfusion with old blood. Pathologies observed after transfusion with old blood, together with the favorable response to Hp supplementation, allowed us to define the in vivo consequences of the rbc storage lesion as storage-related posttransfusion hemolysis producing Hb-driven pathophysiology. Hb sequestration by Hp might therefore be a therapeutic modality for enhancing transfusion safety in severely ill or massively transfused patients.
Image processing and machine learning in the morphological analysis of blood cells.
Rodellar, J; Alférez, S; Acevedo, A; Molina, A; Merino, A
2018-05-01
This review focuses on how image processing and machine learning can be useful for the morphological characterization and automatic recognition of cell images captured from peripheral blood smears. The basics of the 3 core elements (segmentation, quantitative features, and classification) are outlined, and recent literature is discussed. Although red blood cells are a significant part of this context, this study focuses on malignant lymphoid cells and blast cells. There is no doubt that these technologies may help the cytologist to perform efficient, objective, and fast morphological analysis of blood cells. They may also help in the interpretation of some morphological features and may serve as learning and survey tools. Although research is still needed, it is important to define screening strategies to exploit the potential of image-based automatic recognition systems integrated in the daily routine of laboratories along with other analysis methodologies. © 2018 John Wiley & Sons Ltd.
Increasing patient safety and efficiency in transfusion therapy using formal process definitions.
Henneman, Elizabeth A; Avrunin, George S; Clarke, Lori A; Osterweil, Leon J; Andrzejewski, Chester; Merrigan, Karen; Cobleigh, Rachel; Frederick, Kimberly; Katz-Bassett, Ethan; Henneman, Philip L
2007-01-01
The administration of blood products is a common, resource-intensive, and potentially problem-prone area that may place patients at elevated risk in the clinical setting. Much of the emphasis in transfusion safety has been targeted toward quality control measures in laboratory settings where blood products are prepared for administration as well as in automation of certain laboratory processes. In contrast, the process of transfusing blood in the clinical setting (ie, at the point of care) has essentially remained unchanged over the past several decades. Many of the currently available methods for improving the quality and safety of blood transfusions in the clinical setting rely on informal process descriptions, such as flow charts and medical algorithms, to describe medical processes. These informal descriptions, although useful in presenting an overview of standard processes, can be ambiguous or incomplete. For example, they often describe only the standard process and leave out how to handle possible failures or exceptions. One alternative to these informal descriptions is to use formal process definitions, which can serve as the basis for a variety of analyses because these formal definitions offer precision in the representation of all possible ways that a process can be carried out in both standard and exceptional situations. Formal process definitions have not previously been used to describe and improve medical processes. The use of such formal definitions to prospectively identify potential error and improve the transfusion process has not previously been reported. The purpose of this article is to introduce the concept of formally defining processes and to describe how formal definitions of blood transfusion processes can be used to detect and correct transfusion process errors in ways not currently possible using existing quality improvement methods.
Yurkovich, James T.; Yang, Laurence; Palsson, Bernhard O.; ...
2017-03-06
Deep-coverage metabolomic profiling has revealed a well-defined development of metabolic decay in human red blood cells (RBCs) under cold storage conditions. A set of extracellular biomarkers has been recently identified that reliably defines the qualitative state of the metabolic network throughout this metabolic decay process. Here, we extend the utility of these biomarkers by using them to quantitatively predict the concentrations of other metabolites in the red blood cell. We are able to accurately predict the concentration profile of 84 of the 91 (92%) measured metabolites ( p < 0.05) in RBC metabolism using only measurements of these five biomarkers.more » The median of prediction errors (symmetric mean absolute percent error) across all metabolites was 13%. Furthermore, the ability to predict numerous metabolite concentrations from a simple set of biomarkers offers the potential for the development of a powerful workflow that could be used to evaluate the metabolic state of a biological system using a minimal set of measurements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yurkovich, James T.; Yang, Laurence; Palsson, Bernhard O.
Deep-coverage metabolomic profiling has revealed a well-defined development of metabolic decay in human red blood cells (RBCs) under cold storage conditions. A set of extracellular biomarkers has been recently identified that reliably defines the qualitative state of the metabolic network throughout this metabolic decay process. Here, we extend the utility of these biomarkers by using them to quantitatively predict the concentrations of other metabolites in the red blood cell. We are able to accurately predict the concentration profile of 84 of the 91 (92%) measured metabolites ( p < 0.05) in RBC metabolism using only measurements of these five biomarkers.more » The median of prediction errors (symmetric mean absolute percent error) across all metabolites was 13%. Furthermore, the ability to predict numerous metabolite concentrations from a simple set of biomarkers offers the potential for the development of a powerful workflow that could be used to evaluate the metabolic state of a biological system using a minimal set of measurements.« less
Laboratory hemostasis: from biology to the bench.
Lippi, Giuseppe; Favaloro, Emmanuel J
2018-06-27
Physiological hemostasis is an intricate biological system, where procoagulant and anticoagulant forces interplay and preserves blood fluidity when blood vessels are intact, or trigger clot formation to prevent excessive bleeding when blood vessels are injured. The modern model of hemostasis is divided into two principal phases. The first, defined as primary hemostasis, involves the platelet-vessel interplay, whilst the second, defined as secondary hemostasis, mainly involves coagulation factors, damaged cells and platelet surfaces, where the so-called coagulation cascade rapidly develops. The activation and amplification of the coagulation cascade is finely modulated by the activity of several physiological inhibitors. Once bleeding has been efficiently stopped by blood clot formation, dissolution of the thrombus is essential to restore vessel permeability. This process, known as fibrinolysis, also develops through coordinate action of a vast array of proteins and enzymes. An accurate diagnosis of hemostasis disturbance entails a multifaceted approach, encompassing family and personal history of hemostatic disorders, accurate collection of clinical signs and symptoms, integrated with laboratory hemostasis testing. Regarding laboratory testing, a reasonable approach entails classifying hemostasis testing according to cost, complexity and available clinical information. Laboratory workout may hence initiate with some rapid and inexpensive "screening" tests, characterized by high negative predictive value, then followed by second- or third-line analyses, specifically aimed to clarify the nature and severity of bleeding or thrombotic phenotype. This article aims to provide a general overview of the hemostatic process, and to provide some general suggestions to optimally facilitate laboratory hemostasis testing.
NASA Astrophysics Data System (ADS)
Asselin, Marie-Claude; Cunningham, Vincent J.; Amano, Shigeko; Gunn, Roger N.; Nahmias, Claude
2004-03-01
A non-invasive alternative to arterial blood sampling for the generation of a blood input function for brain positron emission tomography (PET) studies is presented. The method aims to extract the dimensions of the blood vessel directly from PET images and to simultaneously correct the radioactivity concentration for partial volume and spillover. This involves simulation of the tomographic imaging process to generate images of different blood vessel and background geometries and selecting the one that best fits, in a least-squares sense, the acquired PET image. A phantom experiment was conducted to validate the method which was then applied to eight subjects injected with 6-[18F]fluoro-L-DOPA and one subject injected with [11C]CO-labelled red blood cells. In the phantom study, the diameter of syringes filled with an 11C solution and inserted into a water-filled cylinder were estimated with an accuracy of half a pixel (1 mm). The radioactivity concentration was recovered to 100 ± 4% in the 8.7 mm diameter syringe, the one that most closely approximated the superior sagittal sinus. In the human studies, the method systematically overestimated the calibre of the superior sagittal sinus by 2-3 mm compared to measurements made in magnetic resonance venograms on the same subjects. Sources of discrepancies related to the anatomy of the blood vessel were found not to be fundamental limitations to the applicability of the method to human subjects. This method has the potential to provide accurate quantification of blood radioactivity concentration from PET images without the need for blood samples, corrections for delay and dispersion, co-registered anatomical images, or manually defined regions of interest.
Processing methods for photoacoustic Doppler flowmetry with a clinical ultrasound scanner
NASA Astrophysics Data System (ADS)
Bücking, Thore M.; van den Berg, Pim J.; Balabani, Stavroula; Steenbergen, Wiendelt; Beard, Paul C.; Brunker, Joanna
2018-02-01
Photoacoustic flowmetry (PAF) based on time-domain cross correlation of photoacoustic signals is a promising technique for deep tissue measurement of blood flow velocity. Signal processing has previously been developed for single element transducers. Here, the processing methods for acoustic resolution PAF using a clinical ultrasound transducer array are developed and validated using a 64-element transducer array with a -6 dB detection band of 11 to 17 MHz. Measurements were performed on a flow phantom consisting of a tube (580 μm inner diameter) perfused with human blood flowing at physiological speeds ranging from 3 to 25 mm / s. The processing pipeline comprised: image reconstruction, filtering, displacement detection, and masking. High-pass filtering and background subtraction were found to be key preprocessing steps to enable accurate flow velocity estimates, which were calculated using a cross-correlation based method. In addition, the regions of interest in the calculated velocity maps were defined using a masking approach based on the amplitude of the cross-correlation functions. These developments enabled blood flow measurements using a transducer array, bringing PAF one step closer to clinical applicability.
Beiske, K; Burchill, S A; Cheung, I Y; Hiyama, E; Seeger, R C; Cohn, S L; Pearson, A D J; Matthay, K K
2009-01-01
Disseminating disease is a predictive and prognostic indicator of poor outcome in children with neuroblastoma. Its accurate and sensitive assessment can facilitate optimal treatment decisions. The International Neuroblastoma Risk Group (INRG) Task Force has defined standardised methods for the determination of minimal disease (MD) by immunocytology (IC) and quantitative reverse transcriptase-polymerase chain reaction (QRT-PCR) using disialoganglioside GD2 and tyrosine hydroxylase mRNA respectively. The INRG standard operating procedures (SOPs) define methods for collecting, processing and evaluating bone marrow (BM), peripheral blood (PB) and peripheral blood stem cell harvest by IC and QRT-PCR. Sampling PB and BM is recommended at diagnosis, before and after myeloablative therapy and at the end of treatment. Peripheral blood stem cell products should be analysed at the time of harvest. Performing MD detection according to INRG SOPs will enable laboratories throughout the world to compare their results and thus facilitate quality-controlled multi-centre prospective trials to assess the clinical significance of MD and minimal residual disease in heterogeneous patient groups. PMID:19401690
Automatic diagnosis of malaria based on complete circle-ellipse fitting search algorithm.
Sheikhhosseini, M; Rabbani, H; Zekri, M; Talebi, A
2013-12-01
Diagnosis of malaria parasitemia from blood smears is a subjective and time-consuming task for pathologists. The automatic diagnostic process will reduce the diagnostic time. Also, it can be worked as a second opinion for pathologists and may be useful in malaria screening. This study presents an automatic method for malaria diagnosis from thin blood smears. According to this fact that malaria life cycle is started by forming a ring around the parasite nucleus, the proposed approach is mainly based on curve fitting to detect parasite ring in the blood smear. The method is composed of six main phases: stain object extraction step, which extracts candidate objects that may be infected by malaria parasites. This phase includes stained pixel extraction step based on intensity and colour, and stained object segmentation by defining stained circle matching. Second step is preprocessing phase which makes use of nonlinear diffusion filtering. The process continues with detection of parasite nucleus from resulted image of previous step according to image intensity. Fourth step introduces a complete search process in which the circle search step identifies the direction and initial points for direct least-square ellipse fitting algorithm. Furthermore in the ellipse searching process, although parasite shape is completed undesired regions with high error value are removed and ellipse parameters are modified. Features are extracted from the parasite candidate region instead of whole candidate object in the fifth step. By employing this special feature extraction way, which is provided by special searching process, the necessity of employing clump splitting methods is removed. Also, defining stained circle matching process in the first step speeds up the whole procedure. Finally, a series of decision rules are applied on the extracted features to decide on the positivity or negativity of malaria parasite presence. The algorithm is applied on 26 digital images which are provided from thin blood smear films. The images are contained 1274 objects which may be infected by parasite or healthy. Applying the automatic identification of malaria on provided database showed a sensitivity of 82.28% and specificity of 98.02%. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.
The Effect of Knowledge Linking Levels in Biology Lessons upon Students' Knowledge Structure
ERIC Educational Resources Information Center
Wadouh, Julia; Liu, Ning; Sandmann, Angela; Neuhaus, Birgit J.
2014-01-01
Knowledge structure is an important aspect for defining students' competency in biology learning, but how knowledge structure is influenced by the teaching process in naturalistic biology classroom settings has scarcely been empirically investigated. In this study, 49 biology lessons in the teaching unit "blood and circulatory system" in…
Enhancing diabetes management while teaching quality improvement methods.
Sievers, Beth A; Negley, Kristin D F; Carlson, Marny L; Nelson, Joyce L; Pearson, Kristina K
2014-01-01
Six medical units realized that they were having issues with accurate timing of bedtime blood glucose measurement for their patients with diabetes. They decided to investigate the issues by using their current staff nurse committee structure. The clinical nurse specialists and nurse education specialists decided to address the issue by educating and engaging the staff in the define, measure, analyze, improve, control (DMAIC) framework process. They found that two issues needed to be improved, including timing of bedtime blood glucose measurement and snack administration and documentation. Several educational interventions were completed and resulted in improved timing of bedtime glucose measurement and bedtime snack documentation. The nurses understood the DMAIC process, and collaboration and cohesion among the medical units was enhanced. Copyright 2014, SLACK Incorporated.
Hypertension despite dehydration during severe pediatric diabetic ketoacidosis.
Deeter, Kristina H; Roberts, Joan S; Bradford, Heidi; Richards, Todd; Shaw, Dennis; Marro, Kenneth; Chiu, Harvey; Pihoker, Catherine; Lynn, Anne; Vavilala, Monica S
2011-06-01
Diabetic ketoacidosis (DKA) may result in both dehydration and cerebral edema but these processes may have opposing effects on blood pressure. We examined the relationship between dehydration and blood pressure in pediatric DKA. A retrospective review was performed at Seattle Children's Hospital, Seattle, WA. Participants were hospitalized children less than 18 yr. Intervention(s) or main exposure was to patients with DKA (venous pH < 7.3, glucose > 300 mg/dL, HCO(3) < 15 mEq/L, and urinary ketosis). Dehydration was calculated as percent body weight lost at admission compared to discharge. Hypertension (systolic and/or diastolic blood pressure (DBP) percentile > 95%) was defined based on National Heart, Lung, and Blood Institute (NHLBI, 2004) nomograms and hypotension was defined as systolic blood pressure (SBP) <70 + 2 [age]. Thirty-three patients (median 10.9 yr; range 10 months to 17 yr) were included. Fifty-eight percent of patients (19/33) had hypertension on admission before treatment and 82% had hypertension during the first 6 h of admission. None had admission hypotension. Hypertension 48 h after treatment and weeks after discharge was common (28 and 19%, respectively). Based on weight gained by discharge, 27% of patients had mild, 61% had moderate, and 12% presented with severe dehydration. Despite dehydration, most children admitted with severe DKA had hypertension. © 2011 John Wiley & Sons A/S.
A novel platelet concentrate: titanium-prepared platelet-rich fibrin.
Tunalı, Mustafa; Özdemir, Hakan; Küçükodacı, Zafer; Akman, Serhan; Yaprak, Emre; Toker, Hülya; Fıratlı, Erhan
2014-01-01
We developed a new product called titanium-prepared platelet-rich fibrin (T-PRF). The T-PRF method is based on the hypothesis that titanium may be more effective in activating platelets than the silica activators used with glass tubes in Chouckroun's leukocyte- and platelet-rich fibrin (L-PRF) method. In this study, we aimed to define the structural characteristics of T-PRF and compare it with L-PRF. Blood samples were collected from 10 healthy male volunteers. The blood samples were drawn using a syringe. Nine milliliters was transferred to a dry glass tube, and 9 mL was transferred to a titanium tube. Half of each clot (i.e., the blood that was clotted using T-PRF or L-PRF) was processed with a scanning electron microscope (SEM). The other half of each clot was processed for fluorescence microscopy analysis and light microscopy analysis. The T-PRF samples seemed to have a highly organized network with continuous integrity compared to the other L-PRF samples. Histomorphometric analysis showed that T-PRF fibrin network covers larger area than L-PRF fibrin network; also fibrin seemed thicker in the T-PRF samples. This is the first human study to define T-PRF as an autogenous leukocyte- and platelet-rich fibrin product. The platelet activation by titanium seems to offer some high characteristics to T-PRF.
Blood collection, components preparation and distribution in Iran, 2008-2012.
Omidkhoda, Azadeh; Amini Kafi-Abad, Sedigheh; Pourfatollah, Ali Akbar; Maghsudlu, Mahtab
2016-02-01
The information about the dynamics of blood collection, components preparation and distribution in Iran was measured and compared during 2008-2012. The survey instruments were based on collecting data from all 220 blood collections and blood processing centers over the country, registering them in the validated data base and reporting them to headquarter of Iranian Blood Transfusion Organization. Total blood collection increased during this period, and in 2012 represented a 12.6 percent increase compared to that in 2008. On average, red blood cells, fresh frozen plasma and platelet concentrate were prepared from 95.5 ± 2.4, 81 ± 3.8 and 47 ± 8.8 percent of all whole blood collection. From 2008 to 2011, the distribution of whole blood and fresh frozen plasma revealed different patterns. For whole blood, declines were noted, while for fresh frozen plasma increases were reported. In addition the distribution of red blood cells and platelet concentrate did not change considerably. Also between 2008 and 2012, the mean percentage of outdated and discarded units was 3.6 ± 1 and 5.2 ± 4.6. This study as a first national survey provides comprehensive information about the blood supply, components preparation and distribution, and helps to define strategy for the future. Copyright © 2016 Elsevier Ltd. All rights reserved.
Vongsakulyanon, A; Kitpoka, P; Kunakorn, M; Srikhirin, T
2015-12-01
To develop reliable and convenient methods for Miltenberger (Mi(a) ) blood group typing. To apply real-time polymerase chain reaction (qPCR) melting curve analysis to Mi(a) blood group typing. The Mi(a) blood group is the collective set of glycophorin hybrids in the MNS blood group system. Mi(a+) blood is common among East Asians and is also found in the Thai population. Incompatible Mi(a) blood transfusions pose the risk of life-threatening haemolysis; therefore, Mi(a) blood group typing is necessary in ethnicities where the Mi(a) blood group is prevalent. One hundred and forty-three blood samples from Thai blood donors were used in the study. The samples included 50 Mi(a+) samples and 93 Mi(a-) samples, which were defined by serology. The samples were typed by Mi(a) typing qPCR, and 50 Mi(a+) samples were sequenced to identify the Mi(a) subtypes. Mi(a) subtyping qPCR was performed to define GP.Mur. Both Mi(a) typing and Mi(a) subtyping were tested on a conventional PCR platform. The results of Mi(a) typing qPCR were all concordant with serology. Sequencing of the 50 Mi(a+) samples revealed 47 GP.Mur samples and 3 GP.Hop or Bun samples. Mi(a) subtyping qPCR was the supplementary test used to further define GP.Mur from other Mi(a) subtypes. Both Mi(a) typing and Mi(a) subtyping performed well using a conventional PCR platform. Mi(a) typing qPCR correctly identified Mi(a) blood groups in a Thai population with the feasibility of Mi(a) subtype discrimination, and Mi(a) subtyping qPCR was able to further define GP.Mur from other Mi(a) subtypes. © 2015 British Blood Transfusion Society.
Scriba, Thomas J; Penn-Nicholson, Adam; Shankar, Smitha; Hraha, Tom; Thompson, Ethan G; Sterling, David; Nemes, Elisa; Darboe, Fatoumatta; Suliman, Sara; Amon, Lynn M; Mahomed, Hassan; Erasmus, Mzwandile; Whatney, Wendy; Johnson, John L; Boom, W Henry; Hatherill, Mark; Valvo, Joe; De Groote, Mary Ann; Ochsner, Urs A; Aderem, Alan; Hanekom, Willem A; Zak, Daniel E
2017-11-01
Our understanding of mechanisms underlying progression from Mycobacterium tuberculosis infection to pulmonary tuberculosis disease in humans remains limited. To define such mechanisms, we followed M. tuberculosis-infected adolescents longitudinally. Blood samples from forty-four adolescents who ultimately developed tuberculosis disease (“progressors”) were compared with those from 106 matched controls, who remained healthy during two years of follow up. We performed longitudinal whole blood transcriptomic analyses by RNA sequencing and plasma proteome analyses using multiplexed slow off-rate modified DNA aptamers. Tuberculosis progression was associated with sequential modulation of immunological processes. Type I/II interferon signalling and complement cascade were elevated 18 months before tuberculosis disease diagnosis, while changes in myeloid inflammation, lymphoid, monocyte and neutrophil gene modules occurred more proximally to tuberculosis disease. Analysis of gene expression in purified T cells also revealed early suppression of Th17 responses in progressors, relative to M. tuberculosis-infected controls. This was confirmed in an independent adult cohort who received BCG re-vaccination; transcript expression of interferon response genes in blood prior to BCG administration was associated with suppression of IL-17 expression by BCG-specific CD4 T cells 3 weeks post-vaccination. Our findings provide a timeline to the different immunological stages of disease progression which comprise sequential inflammatory dynamics and immune alterations that precede disease manifestations and diagnosis of tuberculosis disease. These findings have important implications for developing diagnostics, vaccination and host-directed therapies for tuberculosis. Clincialtrials.gov, NCT01119521.
Milenin, Andrzej; Kopernik, Magdalena
2011-01-01
The prosthesis - pulsatory ventricular assist device (VAD) - is made of polyurethane (PU) and biocompatible TiN deposited by pulsed laser deposition (PLD) method. The paper discusses the numerical modelling and computer-aided design of such an artificial organ. Two types of VADs: POLVAD and POLVAD_EXT are investigated. The main tasks and assumptions of the computer program developed are presented. The multiscale model of VAD based on finite element method (FEM) is introduced and the analysis of the stress-strain state in macroscale for the blood chamber in both versions of VAD is shown, as well as the verification of the results calculated by applying ABAQUS, a commercial FEM code. The FEM code developed is based on a new approach to the simulation of multilayer materials obtained by using PLD method. The model in microscale includes two components, i.e., model of initial stresses (residual stress) caused by the deposition process and simulation of active loadings observed in the blood chamber of POLVAD and POLVAD_EXT. The computed distributions of stresses and strains in macro- and microscales are helpful in defining precisely the regions of blood chamber, which can be defined as the failure-source areas.
[Prevalence of high blood pressure in children and adolescents from the city of Maceió, Brazil].
Moura, Adriana A; Silva, Maria A M; Ferraz, Maria R M T; Rivera, Ivan R
2004-01-01
To define the prevalence of high blood pressure in a representative sample of children and adolescents from the city of Maceió, state of Alagoas, Brazil, and to investigate the association of high blood pressure with age, sex and nutritional status. This cross-sectional study was carried out from May 2000 to September 2002. Individuals between 7 and 17 years of age were selected among all the 185,702 students from public and private schools. The size of the sample was defined based on the expected prevalence of hypertension for the age group. After randomization, data were collected through a questionnaire. Blood pressure was measured twice. Weight and height were also measured. High blood pressure was defined as systolic and/or diastolic blood pressure over the 95th percentile in one or in both measures. The final sample included 1,253 students (706 females). One hundred and eighteen students had high blood pressure (mean age 13 years; 44% males). Risk of being overweight and excess weight were identified, respectively, in 9.3 and 4.5% of the students. These variables were significantly associated with high blood pressure. The prevalence of high blood pressure was 9.4%. High blood pressure was significantly more frequent among overweight students and among those at risk for being overweight.
Thiele, Thomas; Steil, Leif; Völker, Uwe; Greinacher, Andreas
2007-01-01
Blood-based therapeutics are cellular or plasma components derived from human blood. Their production requires appropriate selection and treatment of the donor and processing of cells or plasma proteins. In contrast to clearly defined, chemically synthesized drugs, blood-derived therapeutics are highly complex mixtures of plasma proteins or even more complex cells. Pathogen transmission by the product as well as changes in the integrity of blood constituents resulting in loss of function or immune modulation are currently important issues in transfusion medicine. Protein modifications can occur during various steps of the production process, such as acquisition, enrichment of separate components (e.g. coagulation factors, cell populations), virus inactivation, conservation, and storage. Contemporary proteomic strategies allow a comprehensive assessment of protein modifications with high coverage, offer capabilities for qualitative and even quantitative analysis, and for high-throughput protein identification. Traditionally, proteomics approaches predominantly relied on two-dimensional gel electrophoresis (2-DE). Even if 2-DE is still state of the art, it has inherent limitations that are mainly based on the physicochemical properties of the proteins analyzed; for example, proteins with extremes in molecular mass and hydrophobicity (most membrane proteins) are difficult to assess by 2-DE. These limitations have fostered the development of mass spectrometry centered on non-gel-based separation approaches, which have proven to be highly successful and are thus complementing and even partially replacing 2-DE-based approaches. Although blood constituents have been extensively analyzed by proteomics, this technology has not been widely applied to assess or even improve blood-derived therapeutics, or to monitor the production processes. As proteomic technologies have the capacity to provide comprehensive information about changes occurring during processing and storage of blood products, proteomics can potentially guide improvement of pathogen inactivation procedures and engineering of stem cells, and may also allow a better understanding of factors influencing the immunogenicity of blood-derived therapeutics. An important development in proteomics is the reduction of inter-assay variability. This now allows the screening of samples taken from the same product over time or before and after processing. Optimized preparation procedures and storage conditions will reduce the risk of protein alterations, which in turn may contribute to better recovery, reduced exposure to allogeneic proteins, and increased transfusion safety.
Harris, P N A; McNamara, J F; Lye, D C; Davis, J S; Bernard, L; Cheng, A C; Doi, Y; Fowler, V G; Kaye, K S; Leibovici, L; Lipman, J; Llewelyn, M J; Munoz-Price, S; Paul, M; Peleg, A Y; Rodríguez-Baño, J; Rogers, B A; Seifert, H; Thamlikitkul, V; Thwaites, G; Tong, S Y C; Turnidge, J; Utili, R; Webb, S A R; Paterson, D L
2017-08-01
To define standardized endpoints to aid the design of trials that compare antibiotic therapies for bloodstream infections (BSI). Prospective studies, randomized trials or registered protocols comparing antibiotic therapies for BSI, published from 2005 to 2016, were reviewed. Consensus endpoints for BSI studies were defined using a modified Delphi process. Different primary and secondary endpoints were defined for pilot (small-scale studies designed to evaluate protocol design, feasibility and implementation) and definitive trials (larger-scale studies designed to test hypotheses and influence clinical practice), as well as for Staphylococcus aureus and Gram-negative BSI. For pilot studies of S. aureus BSI, a primary outcome of success at day 7 was defined by: survival, resolution of fever, stable/improved Sequential Organ Failure Assessment (SOFA) score and clearance of blood cultures, with no microbiologically confirmed failure up to 90 days. For definitive S. aureus BSI studies, a primary outcome of success at 90 days was defined by survival and no microbiologically confirmed failure. For pilot studies of Gram-negative BSI, a primary outcome of success at day 7 was defined by: survival, resolution of fever and symptoms related to BSI source, stable or improved SOFA score and negative blood cultures. For definitive Gram-negative BSI studies, a primary outcome of survival at 90 days supported by a secondary outcome of success at day 7 (as previously defined) was agreed. These endpoints provide a framework to aid future trial design. Further work will be required to validate these endpoints with respect to patient-centred clinical outcomes. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. All rights reserved.
Baek, Jin Hyen; Yalamanoglu, Ayla; Moon, So-Eun; Gao, Yamei; Buehler, Paul W
2018-03-01
Red blood cell (RBC) oxygen (O 2 ) delivery may be impacted at the tissue, cellular, and molecular levels after storage duration, preservation strategies, and pathogen reduction. Collectively, the preclinical measurement of arterial and venous PO 2 , systemic blood flow, tissue hypoxia-inducible factors (HIFs), pimonidazole adduction, and erythropoietin (EPO) regulation can serve to elucidate differential RBC quality after storage and processing. Donor guinea pig blood was collected, leukoreduced, and stored at 4°C in AS-3 for 1 (fresh) or 14 (stored) days. RBC variables-2,3-diphosphoglycerate, adenosine triphosphate, hemoglobin, morphology, deformability, and in vivo recovery at 24 hours-were measured at each storage duration. Recipient guinea pigs were exchange transfused until 80% volume replacement was achieved. Arterial and venous blood gases, systemic blood flow, renal HIF-1α and HIF-2α, renal EPO mRNA, plasma EPO, and renal tissue pimonidazole adduction were measured after transfusion. RBC variables declined significantly with storage; however, hemolysis and in vivo recovery remained within the allowable limits for human blood storage. Posttransfusion arterial and venous PO 2 and systemic blood flow decreased, and renal HIFs, EPO mRNA, and pimonidazole adducts increased. Subsequently, EPO accumulated in plasma indicating decreased O 2 availability in the kidneys. Conversely, all variables remained at basal levels in the fresh blood group. The evaluation of renal O 2 homeostasis after transfusion represents an effective approach to defining RBC quality between predicate and novel processing. Methods are adapted from standardized techniques and ideal for preclinical evaluation. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Whole Blood § 640.1 Whole Blood. The proper name of this product shall be Whole Blood. Whole Blood is defined as blood collected from human donors for transfusion... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Whole Blood. 640.1 Section 640.1 Food and Drugs...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Whole Blood. 640.1 Section 640.1 Food and Drugs... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Whole Blood § 640.1 Whole Blood. The proper name of this product shall be Whole Blood. Whole Blood is defined as blood collected from human donors for transfusion...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Whole Blood. 640.1 Section 640.1 Food and Drugs... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Whole Blood § 640.1 Whole Blood. The proper name of this product shall be Whole Blood. Whole Blood is defined as blood collected from human donors for transfusion...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Whole Blood. 640.1 Section 640.1 Food and Drugs... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Whole Blood § 640.1 Whole Blood. The proper name of this product shall be Whole Blood. Whole Blood is defined as blood collected from human donors for transfusion...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Whole Blood. 640.1 Section 640.1 Food and Drugs... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Whole Blood § 640.1 Whole Blood. The proper name of this product shall be Whole Blood. Whole Blood is defined as blood collected from human donors for transfusion...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pieroni, R.R.; Maspes, V.; Jamra, M.A.
1959-05-01
The number of red blood cells present in the circulatory system of an individual at any given instant depends on various facts, some of which are related to characteristics of the red cells themselves and some to the processes of formation and destruction. An attempt is made to establish on precise experimental data analytical expressions which relate the number of erythrocytes to parameters defined by the life span of the erythrocytes, the processes of formation and destruction, and time. (J.S.R)
21 CFR 640.10 - Red Blood Cells.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.10 Red Blood Cells. The proper name of this product shall be Red Blood Cells. The product is defined as red blood cells remaining... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Red Blood Cells. 640.10 Section 640.10 Food and...
21 CFR 640.10 - Red Blood Cells.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.10 Red Blood Cells. The proper name of this product shall be Red Blood Cells. The product is defined as red blood cells remaining... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Red Blood Cells. 640.10 Section 640.10 Food and...
21 CFR 640.10 - Red Blood Cells.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.10 Red Blood Cells. The proper name of this product shall be Red Blood Cells. The product is defined as red blood cells remaining... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Red Blood Cells. 640.10 Section 640.10 Food and...
21 CFR 640.10 - Red Blood Cells.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.10 Red Blood Cells. The proper name of this product shall be Red Blood Cells. The product is defined as red blood cells remaining... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Red Blood Cells. 640.10 Section 640.10 Food and...
21 CFR 640.10 - Red Blood Cells.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Red Blood Cells. 640.10 Section 640.10 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.10 Red Blood Cells. The proper name of this product shall be Red Blood Cells. The product is defined as red blood cells remaining...
1990-01-01
This report aims to clarify the position of the hospital blood bank in the light of product liability legislation contained in the Consumer Protection Act of 1987. Blood has been defined a 'product' under this Act. The potential for the blood bank to be seen in the role of 'supplier', 'keeper' or even 'producer' in the chain of product supply to the patient is explained and advice given on the resulting implications for blood bank practice. It will be necessary to define, adopt and implement standard operating procedures (SOP) for all blood bank activities. Guidance is given on the format, preparation and content of SOPs and specimen examples offered. The fundamental importance of quality assurance is emphasized.
Critical issues for engineering cord blood stem cells to produce insulin.
Denner, Larry; Urban, Randall J
2008-09-01
The objectives of using cord blood stem cells for treating type 1 diabetes are simple in principle yet complex in biological and molecular mechanisms. These are defined by the complexity of the insulin-producing unit of the pancreas, the islet. Islets are composed of various cell types that arise from diverse lineages and communicate by hormones, growth factors and small-molecule mediators. These processes are regulated by integration of signal transduction pathways. While advances have been made to engineer umbilical cord blood stem cells to produce insulin, these studies only illuminate the potential of such cells to fulfil a necessary, but not sufficient, requirement for transplantation. The challenges ahead demand detailed understanding of molecular mechanisms to move from an opportunistic, phenotypic approach to transplantation and amelioration of blood glucose, to an orderly and logical approach to a biologically and medically meaningful solution. The issues include expansion to generate large numbers of cells, self-renewal to regulate the destiny of cord blood stem cells to repopulate the hematopoietic system, and multipotency of stem cells to generate the distinct cell types of an islet.
21 CFR 1271.3 - How does FDA define important terms in this part?
Code of Federal Regulations, 2014 CFR
2014-04-01
... resulting from the transfusion of blood or blood components and/or infusion of fluids. (q) Quarantine means... blood, manipulated autologous chondrocytes, epithelial cells on a synthetic matrix, and semen or other... transplantation; (2) Whole blood or blood components or blood derivative products subject to listing under parts...
21 CFR 1271.3 - How does FDA define important terms in this part?
Code of Federal Regulations, 2012 CFR
2012-04-01
... resulting from the transfusion of blood or blood components and/or infusion of fluids. (q) Quarantine means... blood, manipulated autologous chondrocytes, epithelial cells on a synthetic matrix, and semen or other... transplantation; (2) Whole blood or blood components or blood derivative products subject to listing under parts...
21 CFR 1271.3 - How does FDA define important terms in this part?
Code of Federal Regulations, 2013 CFR
2013-04-01
... resulting from the transfusion of blood or blood components and/or infusion of fluids. (q) Quarantine means... blood, manipulated autologous chondrocytes, epithelial cells on a synthetic matrix, and semen or other... transplantation; (2) Whole blood or blood components or blood derivative products subject to listing under parts...
21 CFR 1271.3 - How does FDA define important terms in this part?
Code of Federal Regulations, 2011 CFR
2011-04-01
... resulting from the transfusion of blood or blood components and/or infusion of fluids. (q) Quarantine means... blood, manipulated autologous chondrocytes, epithelial cells on a synthetic matrix, and semen or other... transplantation; (2) Whole blood or blood components or blood derivative products subject to listing under parts...
From waste to (fool's) gold: promissory and profit values of cord blood.
Haw, Jennie
2015-12-01
According to biomedical discourse, cord blood has been transformed from 'waste' to 'clinical gold' because of its potential for use in treatments. Private cord blood banks deploy clinical discourse to market their services to prospective parents, encouraging them to pay to bank cord blood as a form of 'biological insurance' to ensure their child's future health. Social scientists have examined new forms of (bio)value produced in biological materials emergent with contemporary biotechnologies. This paper contributes to this literature by examining the social and technical production of value in cord blood units collected for private banking. Value, in this paper is defined as a socio-cultural concept in which an object is made meaningful, or valuable, through its relations with social actors and within specific regimes of value. I draw on in-depth interviews with women who banked cord blood and key informants in private banks in Canada, to analyze how social actors produced cord blood as a valuable biological object. I show that a cord blood unit holds promissory value for women who bank and profit value for private banks and that these values are folded into each other and the biological material itself. Analyzing how specific cord blood units are made valuable provides insight into the multiple and possibly competing values of biological materials and the tensions that may arise between social actors and forms of knowledge during the valuing process.
NASA Astrophysics Data System (ADS)
Imms, Ryan; Hu, Sijung; Azorin-Peris, Vicente; Trico, Michaël.; Summers, Ron
2014-03-01
Non-contact imaging photoplethysmography (PPG) is a recent development in the field of physiological data acquisition, currently undergoing a large amount of research to characterize and define the range of its capabilities. Contact-based PPG techniques have been broadly used in clinical scenarios for a number of years to obtain direct information about the degree of oxygen saturation for patients. With the advent of imaging techniques, there is strong potential to enable access to additional information such as multi-dimensional blood perfusion and saturation mapping. The further development of effective opto-physiological monitoring techniques is dependent upon novel modelling techniques coupled with improved sensor design and effective signal processing methodologies. The biometric signal and imaging processing platform (bSIPP) provides a comprehensive set of features for extraction and analysis of recorded iPPG data, enabling direct comparison with other biomedical diagnostic tools such as ECG and EEG. Additionally, utilizing information about the nature of tissue structure has enabled the generation of an engineering model describing the behaviour of light during its travel through the biological tissue. This enables the estimation of the relative oxygen saturation and blood perfusion in different layers of the tissue to be calculated, which has the potential to be a useful diagnostic tool.
Karvounis, E C; Tsakanikas, V D; Fotiou, E; Fotiadis, D I
2010-01-01
The paper proposes a novel Extensible Markup Language (XML) based format called ART-ML that aims at supporting the interoperability and the reuse of models of blood flow, mass transport and plaque formation, exported by ARTool. ARTool is a platform for the automatic processing of various image modalities of coronary and carotid arteries. The images and their content are fused to develop morphological models of the arteries in easy to handle 3D representations. The platform incorporates efficient algorithms which are able to perform blood flow simulation. In addition atherosclerotic plaque development is estimated taking into account morphological, flow and genetic factors. ART-ML provides a XML format that enables the representation and management of embedded models within the ARTool platform and the storage and interchange of well-defined information. This approach influences in the model creation, model exchange, model reuse and result evaluation.
Riquelme, Paloma; Wundt, Judith; Hutchinson, James A; Brulport, Marc; Jun, Yu; Sotnikova, Anna; Girreser, Ulrich; Braun, Felix; Gövert, Felix; Soria, Bernat; Nüssler, Andreas; Clement, Bernd; Hengstler, Jan G; Fändrich, Fred
2009-03-01
Under certain culture conditions human peripheral blood monocytes may be induced to express phenotypic markers of non-haematopoietic lineages, including hepatocyte-defining traits. One such example, the NeoHepatocyte, was previously shown to express a broad panel of hepatocyte-like marker antigens and metabolic activities, both in vitro and following engraftment in the liver of immunodeficient mice. In this report, a refined description of NeoHepatocytes, with regard to their expression of xenobiotic-metabolising enzymes, morphology, hepatocyte marker expression and cell surface phenotype, is presented in comparison with human macrophages in defined states of activation. Contrary to prior assertions, it would seem more likely that NeoHepatocytes express particular hepatocyte-defining genes during a normal programme of macrophage differentiation rather than undergoing a process of transdifferentiation to become hepatocyte-like cells.
Human spleen and red blood cells
NASA Astrophysics Data System (ADS)
Pivkin, Igor; Peng, Zhangli; Karniadakis, George; Buffet, Pierre; Dao, Ming
2016-11-01
Spleen plays multiple roles in the human body. Among them is removal of old and altered red blood cells (RBCs), which is done by filtering cells through the endothelial slits, small micron-sized openings. There is currently no experimental technique available that allows us to observe RBC passage through the slits. It was previously noticed that people without a spleen have less deformable red blood cells, indicating that the spleen may play a role in defining the size and shape of red blood cells. We used detailed RBC model implemented within the Dissipative Particle Dynamics (DPD) simulation framework to study the filter function of the spleen. Our results demonstrate that spleen indeed plays major role in defining the size and shape of the healthy human red blood cells.
Frohner, Matthias; Urbauer, Philipp; Sauermann, Stefan
2017-01-01
Based on recent telemonitoring activities in Austria for enabling integrated health care, the communication interfaces between personal health devices (e.g. blood pressure monitor) and personal health gateway devices (e.g. smartphone, routing received information to wide area networks) play an important role. In order to ease testing of the Bluetooth Low Energy interface functionality of the personal health gateway devices, a personal health device simulator was developed. Based on specifications from the Bluetooth SIG a XML software test configuration file structure is defined that declares the specific features of the personal health devices simulated. Using this configuration file, different scenarios are defined, e.g. send a single measurement result from a blood pressure reading or sending multiple (historic) weight scale readings. The simulator is intended to be used for educational purposes in lectures, where the number of physical personal health devices can be reduced and learning can be improved. It could be shown that this simulator assists the development process of mHealth applications by reducing the time needed for development and testing.
Robust approach to ocular fundus image analysis
NASA Astrophysics Data System (ADS)
Tascini, Guido; Passerini, Giorgio; Puliti, Paolo; Zingaretti, Primo
1993-07-01
The analysis of morphological and structural modifications of retinal blood vessels plays an important role both to establish the presence of some systemic diseases as hypertension and diabetes and to study their course. The paper describes a robust set of techniques developed to quantitatively evaluate morphometric aspects of the ocular fundus vascular and micro vascular network. They are defined: (1) the concept of 'Local Direction of a vessel' (LD); (2) a special form of edge detection, named Signed Edge Detection (SED), which uses LD to choose the convolution kernel in the edge detection process and is able to distinguish between the left or the right vessel edge; (3) an iterative tracking (IT) method. The developed techniques use intensively both LD and SED in: (a) the automatic detection of number, position and size of blood vessels departing from the optical papilla; (b) the tracking of body and edges of the vessels; (c) the recognition of vessel branches and crossings; (d) the extraction of a set of features as blood vessel length and average diameter, arteries and arterioles tortuosity, crossing position and angle between two vessels. The algorithms, implemented in C language, have an execution time depending on the complexity of the currently processed vascular network.
... Is A Standard Drink? Drinking Levels Defined Drinking Levels Defined Moderate alcohol consumption: According to the "Dietary ... of drinking that brings blood alcohol concentration (BAC) levels to 0.08 g/dL. This typically occurs ...
Neurotoxicology of the Brain Barrier System: New Implications
Zheng, Wei
2014-01-01
The concept of a barrier system in the brain has existed for nearly a century. The barrier that separates the blood from the cerebral interstitial fluid is defined as the blood-brain barrier, while the one that discontinues the circulation between the blood and cerebrospinal fluid is named the blood-cerebrospinal fluid barrier. Evidence in the past decades suggests that brain barriers are subject to toxic insults from neurotoxic chemicals circulating in blood. The aging process and some disease states render barriers more vulnerable to insults arising inside and outside the barriers. The implication of brain barriers in certain neurodegenerative diseases is compelling, although the contribution of chemical-induced barrier dysfunction in the etiology of any of these disorders remains poorly understood. This review examines what is currently understood about brain barrier systems in central nervous system disorders by focusing on chemical-induced neurotoxicities including those associated with nitrobenzenes, N-methyl-D-aspartate, cyclosporin A, pyridostigmine bromide, aluminum, lead, manganese, 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine, and 3-nitropropionic acid. Contemporary research questions arising from this growing understanding show enormous promises for brain researchers, toxicologists, and clinicians. PMID:11778669
Health Instruction Packages: How to Take a Blood Pressure.
ERIC Educational Resources Information Center
Lancaster, Carolyn; And Others
Text, illustrations, and exercises are utilized in these four learning modules to teach dental hygiene students, nursing students, and the general public how to measure blood pressure. The first module, "Can You Take a Blood Pressure?" by Carolyn Lancaster, defines blood pressure, distinguishes between systolic and diastolic pressure and…
Hueper, Katja; Vogel-Claussen, Jens; Parikh, Megha A.; Austin, John H. M.; Bluemke, David A.; Carr, James; Choi, Jiwoong; Goldstein, Thomas A.; Gomes, Antoinette S.; Hoffman, Eric A.; Kawut, Steven M.; Lima, Joao; Michos, Erin D.; Post, Wendy S.; Po, Ming Jack; Prince, Martin R.; Liu, Kiang; Rabinowitz, Dan; Skrok, Jan; Smith, Ben M.; Watson, Karol; Yin, Youbing; Zambeli-Ljepovic, Alan M.
2015-01-01
Rationale: Smoking-related microvascular loss causes end-organ damage in the kidneys, heart, and brain. Basic research suggests a similar process in the lungs, but no large studies have assessed pulmonary microvascular blood flow (PMBF) in early chronic lung disease. Objectives: To investigate whether PMBF is reduced in mild as well as more severe chronic obstructive pulmonary disease (COPD) and emphysema. Methods: PMBF was measured using gadolinium-enhanced magnetic resonance imaging (MRI) among smokers with COPD and control subjects age 50 to 79 years without clinical cardiovascular disease. COPD severity was defined by standard criteria. Emphysema on computed tomography (CT) was defined by the percentage of lung regions below −950 Hounsfield units (−950 HU) and by radiologists using a standard protocol. We adjusted for potential confounders, including smoking, oxygenation, and left ventricular cardiac output. Measurements and Main Results: Among 144 participants, PMBF was reduced by 30% in mild COPD, by 29% in moderate COPD, and by 52% in severe COPD (all P < 0.01 vs. control subjects). PMBF was reduced with greater percentage emphysema−950HU and radiologist-defined emphysema, particularly panlobular and centrilobular emphysema (all P ≤ 0.01). Registration of MRI and CT images revealed that PMBF was reduced in mild COPD in both nonemphysematous and emphysematous lung regions. Associations for PMBF were independent of measures of small airways disease on CT and gas trapping largely because emphysema and small airways disease occurred in different smokers. Conclusions: PMBF was reduced in mild COPD, including in regions of lung without frank emphysema, and may represent a distinct pathological process from small airways disease. PMBF may provide an imaging biomarker for therapeutic strategies targeting the pulmonary microvasculature. PMID:26067761
Hueper, Katja; Vogel-Claussen, Jens; Parikh, Megha A; Austin, John H M; Bluemke, David A; Carr, James; Choi, Jiwoong; Goldstein, Thomas A; Gomes, Antoinette S; Hoffman, Eric A; Kawut, Steven M; Lima, Joao; Michos, Erin D; Post, Wendy S; Po, Ming Jack; Prince, Martin R; Liu, Kiang; Rabinowitz, Dan; Skrok, Jan; Smith, Ben M; Watson, Karol; Yin, Youbing; Zambeli-Ljepovic, Alan M; Barr, R Graham
2015-09-01
Smoking-related microvascular loss causes end-organ damage in the kidneys, heart, and brain. Basic research suggests a similar process in the lungs, but no large studies have assessed pulmonary microvascular blood flow (PMBF) in early chronic lung disease. To investigate whether PMBF is reduced in mild as well as more severe chronic obstructive pulmonary disease (COPD) and emphysema. PMBF was measured using gadolinium-enhanced magnetic resonance imaging (MRI) among smokers with COPD and control subjects age 50 to 79 years without clinical cardiovascular disease. COPD severity was defined by standard criteria. Emphysema on computed tomography (CT) was defined by the percentage of lung regions below -950 Hounsfield units (-950 HU) and by radiologists using a standard protocol. We adjusted for potential confounders, including smoking, oxygenation, and left ventricular cardiac output. Among 144 participants, PMBF was reduced by 30% in mild COPD, by 29% in moderate COPD, and by 52% in severe COPD (all P < 0.01 vs. control subjects). PMBF was reduced with greater percentage emphysema-950HU and radiologist-defined emphysema, particularly panlobular and centrilobular emphysema (all P ≤ 0.01). Registration of MRI and CT images revealed that PMBF was reduced in mild COPD in both nonemphysematous and emphysematous lung regions. Associations for PMBF were independent of measures of small airways disease on CT and gas trapping largely because emphysema and small airways disease occurred in different smokers. PMBF was reduced in mild COPD, including in regions of lung without frank emphysema, and may represent a distinct pathological process from small airways disease. PMBF may provide an imaging biomarker for therapeutic strategies targeting the pulmonary microvasculature.
Pesavento, S; Bégué, L
2011-04-01
Social marketing uses marketing principles and techniques to induce a target audience to voluntary accept, reject, change or abandon a behaviour for the benefit of individuals, groups, or society as a whole. Thus, individual or societal gain is the primary goal of social marketing. This kind of marketing is frequently used in the United States or in Canada in several fields such as healthcare, social work, or the environment. In 2008, we introduced these strategies and techniques in the field of blood donation in France. This article describes what has been achieved in the last three years and outlines the main steps in the social marketing planning process: analyzing the social marketing environment, defining target audiences and objectives, building and implementing strategies and action plans, evaluating and monitoring. On the way to self-sufficiency, while respecting donors, social marketing is additional to the work done by the blood collection staffs, communication teams, and volunteers. Social marketing is a complementary tool to the work done by the blood collection staff, communication teams and blood donation organizations and can help to meet the challenge of self-sufficiency while still allowing for the privacy and rights of donors. Copyright © 2011. Published by Elsevier SAS.
Network simulation-based optimization of centrifugo-pneumatic blood plasma separation
Zehnle, S.; Zengerle, R.; von Stetten, F.; Paust, N.
2017-01-01
Automated and robust separation of 14 μl of plasma from 40 μl of whole blood at a purity of 99.81% ± 0.11% within 43 s is demonstrated for the hematocrit range of 20%–60% in a centrifugal microfluidic polymer disk. At high rotational frequency, red blood cells (RBCs) within whole blood are concentrated in a radial outer RBC collection chamber. Simultaneously, plasma is concentrated in a radial inner pneumatic chamber, where a defined air volume is enclosed and compressed. Subsequent reduction of the rotational frequency to not lower than 25 Hz enables rapid transfer of supernatant plasma into a plasma collection chamber, with highly suppressed resuspension of red blood cells. Disk design and the rotational protocol are optimized to make the process fast, robust, and insusceptible for undesired cell resuspension. Numerical network simulation with lumped model elements is used to predict and optimize the fluidic characteristics. Lysis of the remaining red blood cells in the purified plasma, followed by measurement of the hemoglobin concentration, was used to determine plasma purity. Due to the pneumatic actuation, no surface treatment of the fluidic cartridge or any additional external means are required, offering the possibility for low-cost mass fabrication technologies, such as injection molding or thermoforming. PMID:28798850
Vanícková, Martina; Suttnar, Jirí; Dyr, Jan Evangelista
2006-11-01
The biocompatibility of materials is frequently assessed by blood platelet adhesion, since platelet adhesion plays a considerable role in blood interaction with artificial surfaces. Blood platelets adhesion is an essential event in haemostatic and thrombotic processes. The aim of this study was to simultaneously compare simple biochemical assays widely used for evaluation of platelet static adhesion based on the determination of enzymatic activity of either lactate dehydrogenase (LDH) or acid phosphatase (ACP) in lysates of adhered platelets. Adhesion of platelets from platelet-rich plasma and washed platelets activated by either ADP or thrombin on surfaces covered with fibrinogen and well defined fibrin was studied. The results demonstrated that the amounts of adhered platelets estimated by the LDH method were significantly lower as compared with the amount obtained by ACP method. LDH but not ACP release from platelets during adhesion was shown to take place. It suggests that the LDH method should be used rather as an assay of platelet integrity. The ACP method is much more suitable for quantitative determination of platelet adhesion especially in the development and evaluation of haemocompatibility of new biomaterials.
Peretz, A; Isakovich, N; Pastukh, N; Koifman, A; Glyatman, T; Brodsky, D
2015-08-01
Blood is one of the most important specimens sent to a microbiology laboratory for culture. Most blood cultures are incubated for 5-7 days, except in cases where there is a suspicion of infection caused by microorganisms that proliferate slowly, or infections expressed by a small number of bacteria in the bloodstream. Therefore, at the end of incubation, misidentification of positive cultures and false-negative results are a real possibility. The aim of this work was to perform a confirmation by Gram staining of the lack of any microorganisms in blood cultures that were identified as negative by the BACTEC™ FX system at the end of incubation. All bottles defined as negative by the BACTEC FX system were Gram-stained using an automatic device and inoculated on solid growth media. In our work, 15 cultures that were defined as negative by the BACTEC FX system at the end of the incubation were found to contain microorganisms when Gram-stained. The main characteristic of most bacteria and fungi growing in the culture bottles that were defined as negative was slow growth. This finding raises a problematic issue concerning the need to perform Gram staining of all blood cultures, which could overload the routine laboratory work, especially laboratories serving large medical centers and receiving a large number of blood cultures.
... Disease Venous Thromboembolism Aortic Aneurysm More What is High Blood Pressure? Updated:Feb 27,2018 First, let’s define high ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...
Edwards, Meghan; Ley, Eric; Mirocha, James; Hadjibashi, Anoushiravan Amini; Margulies, Daniel R; Salim, Ali
2010-10-01
Hypotension, defined as systolic blood pressure less than 90 mm Hg, is recognized as a sign of hemorrhagic shock and is a validated prognostic indicator. The definition of hypotension, particularly in the elderly population, deserves attention. We hypothesized that the systolic blood pressure associated with increased mortality resulting from hemorrhagic shock increases with increasing age. The Los Angeles County Trauma Database was queried for all moderate to severely injured patients without major head injuries admitted between 1998 and 2005. Several fit statistic analyses were performed for each systolic blood pressure from 50 to 180 mm Hg to identify the model that most accurately defined hypotension for three age groups. The optimal definition of hypotension for each group was determined from the best fit model. A total of 24,438 patients were analyzed. The optimal definition of hypotension was systolic blood pressure of 100 mm Hg for patients 20 to 49 years, 120 mm Hg for patients 50 to 69 years, and 140 mm Hg for patients 70 years and older. The optimal systolic blood pressure for improved mortality in hemorrhagic shock increases significantly with increasing age. Elderly trauma patients without major head injuries should be considered hypotensive for systolic blood pressure less than 140 mm Hg.
Wei, Bo; Chen, Lei; Kibukawa, Miho; Kang, John; Waskin, Hetty; Marton, Matthew
2016-12-01
Chagas disease is caused by the parasitic infection of Trypanosoma cruzi (T. cruzi). The STOP CHAGAS clinical trial was initiated in 2011 to evaluate posaconazole in treating Chagas disease, with treatment success defined as negative qualitative PCR results of detecting the parasites in blood specimens collected post-treatment. PAXgene Blood DNA tubes were utilized as a simple procedure to collect and process blood specimens. However, the PAXgene blood specimens challenged published T. cruzi PCR methods, resulting in poor sensitivity and reproducibility. To accurately evaluate the treatment efficacy of the clinical study, we developed and validated a robust PCR assay for detecting low level T. cruzi in PAXgene blood specimens. The assay combines a new DNA extraction method with a custom designed qPCR assay, resulting in limit of detection of 0.005 and 0.01 fg/μl for K98 and CL Brener, two representative strains of two of T. cruzi's discrete typing units. Reliable qPCR standard curves were established for both strains to measure parasite loads, with amplification efficiency ≥ 90% and the lower limit of linearity ≥ 0.05 fg/μl. The assay successfully analyzed the samples collected from the STOP CHAGAS study and may prove useful for future global clinical trials evaluating new therapies for asymptomatic chronic Chagas disease.
Predictive factors of the nursing diagnosis sedentary lifestyle in people with high blood pressure.
Guedes, Nirla Gomes; Lopes, Marcos Venícios de Oliveira; Araujo, Thelma Leite de; Moreira, Rafaella Pessoa; Martins, Larissa Castelo Guedes
2011-01-01
To verify the reproducibility of defining the characteristics and related factors in order to identify a sedentary lifestyle in patients with high blood pressure. A cross-sectional study. 310 patients diagnosed with high blood pressure. Socio-demographics and variables related to defining the characteristics and related factors of a sedentary lifestyle. The coefficient Kappa was utilized to analyze the reproducibility. The sensitivity, specificity, and predictive value of the defining characteristics were also analyzed. Logistic regression was applied in the analysis of possible predictors. The defining characteristic with the greatest sensitivity was demonstrates physical deconditioning (98.92%). The characteristics chooses a daily routine lacking physical exercise and verbalizes preference for activities low in physical activity presented higher values of specificity (99.21% and 95.97%, respectively). The following indicators were identified as powerful predictors (85.2%) for the identification of a sedentary lifestyle: demonstrates physical deconditioning, verbalizes preference for activities low in physical activity, and lack of training for accomplishment of physical exercise. © 2010 Wiley Periodicals, Inc.
How large is the typical subarachnoid hemorrhage? A review of current neurosurgical knowledge.
Whitmore, Robert G; Grant, Ryan A; LeRoux, Peter; El-Falaki, Omar; Stein, Sherman C
2012-01-01
Despite the morbidity and mortality of subarachnoid hemorrhage (SAH), the average volume of a typical hemorrhage is not well defined. Animal models of SAH often do not accurately mimic the human disease process. The purpose of this study is to estimate the average SAH volume, allowing standardization of animal models of the disease. We performed a MEDLINE search of SAH volume and erythrocyte counts in human cerebrospinal fluid as well as for volumes of blood used in animal injection models of SAH, from 1956 to 2010. We polled members of the American Association of Neurological Surgeons (AANS) for estimates of typical SAH volume. Using quantitative data from the literature, we calculated the total volume of SAH as equal to the volume of blood clotted in basal cisterns plus the volume of dispersed blood in cerebrospinal fluid. The results of the AANS poll confirmed our estimates. The human literature yielded 322 publications and animal literature, 237 studies. Four quantitative human studies reported blood clot volumes ranging from 0.2 to 170 mL, with a mean of ∼20 mL. There was only one quantitative study reporting cerebrospinal fluid red blood cell counts from serial lumbar puncture after SAH. Dispersed blood volume ranged from 2.9 to 45.9 mL, and we used the mean of 15 mL for our calculation. Therefore, total volume of SAH equals 35 mL. The AANS poll yielded 176 responses, ranging from 2 to 350 mL, with a mean of 33.9 ± 4.4 mL. Based on our estimate of total SAH volume of 35 mL, animal injection models may now become standardized for more accurate portrayal of the human disease process. Copyright © 2012 Elsevier Inc. All rights reserved.
Initial Systolic Time Interval (ISTI) as a Predictor of Intradialytic Hypotension (IDH)
NASA Astrophysics Data System (ADS)
Biesheuvel, J. D.; Vervloet, M. G.; Verdaasdonk, R. M.; Meijer, J. H.
2013-04-01
In haemodialysis treatment the clearance and volume control by the kidneys of a patient are partially replaced by intermittent haemodialysis. Because this artificial process is performed on a limited time scale, unphysiological imbalances in the fluid compartments of the body occur, that can lead to intradialytic hypotensions (IDH). An IDH endangers the efficacy of the haemodialysis session and is associated with dismal clinical endpoints, including mortality. A diagnostic method that predicts the occurrence of these drops in blood pressure could facilitate timely measures for the prevention of IDH. The present study investigates whether the Initial Systolic Time Interval (ISTI) can provide such a diagnostic method. The ISTI is defined as the time difference between the R-peak in the electrocardiogram (ECG) and the C-wave in the impedance cardiogram (ICG) and is considered to be a non-invasive assessment of the time delay between the electrical and mechanical activity of the heart. This time delay has previously been found to depend on autonomic nervous function as well as preload of the heart. Therefore, it can be expected that ISTI may predict an imminent IDH caused by a low circulating blood volume. This ongoing observational clinical study investigates the relationship between changes in ISTI and subsequent drops in blood pressure during haemodialysis. A registration of a complicated dialysis showed a significant correlation between a drop in blood pressure, a decrease in relative blood volume and a substantial increase in ISTI. An uncomplicated dialysis, in which also a considerable amount of fluid was removed, showed no correlations. Both, blood pressure and ISTI remained stable. In conclusion, the preliminary results of the present study show a substantial response of ISTI to haemodynamic instability, indicating an application in optimization and individualisation of the dialysis process.
Frank, Steven M; Rothschild, James A; Masear, Courtney G; Rivers, Richard J; Merritt, William T; Savage, Will J; Ness, Paul M
2013-06-01
The maximum surgical blood order schedule (MSBOS) is used to determine preoperative blood orders for specific surgical procedures. Because the list was developed in the late 1970s, many new surgical procedures have been introduced and others improved upon, making the original MSBOS obsolete. The authors describe methods to create an updated, institution-specific MSBOS to guide preoperative blood ordering. Blood utilization data for 53,526 patients undergoing 1,632 different surgical procedures were gathered from an anesthesia information management system. A novel algorithm based on previously defined criteria was used to create an MSBOS for each surgical specialty. The economic implications were calculated based on the number of blood orders placed, but not indicated, according to the MSBOS. Among 27,825 surgical cases that did not require preoperative blood orders as determined by the MSBOS, 9,099 (32.7%) had a type and screen, and 2,643 (9.5%) had a crossmatch ordered. Of 4,644 cases determined to require only a type and screen, 1,509 (32.5%) had a type and crossmatch ordered. By using the MSBOS to eliminate unnecessary blood orders, the authors calculated a potential reduction in hospital charges and actual costs of $211,448 and $43,135 per year, respectively, or $8.89 and $1.81 per surgical patient, respectively. An institution-specific MSBOS can be created, using blood utilization data extracted from an anesthesia information management system along with our proposed algorithm. Using these methods to optimize the process of preoperative blood ordering can potentially improve operating room efficiency, increase patient safety, and decrease costs.
Ramdath, D Dan; Wolever, Thomas M S; Siow, Yaw Chris; Ryland, Donna; Hawke, Aileen; Taylor, Carla; Zahradka, Peter; Aliani, Michel
2018-05-11
The consumption of pulses is associated with many health benefits. This study assessed post-prandial blood glucose response (PPBG) and the acceptability of food items containing green lentils. In human trials we: (i) defined processing methods (boiling, pureeing, freezing, roasting, spray-drying) that preserve the PPBG-lowering feature of lentils; (ii) used an appropriate processing method to prepare lentil food items, and compared the PPBG and relative glycemic responses (RGR) of lentil and control foods; and (iii) conducted consumer acceptability of the lentil foods. Eight food items were formulated from either whole lentil puree (test) or instant potato (control). In separate PPBG studies, participants consumed fixed amounts of available carbohydrates from test foods, control foods, or a white bread standard. Finger prick blood samples were obtained at 0, 15, 30, 45, 60, 90, and 120 min after the first bite, analyzed for glucose, and used to calculate incremental area under the blood glucose response curve and RGR; glycemic index (GI) was measured only for processed lentils. Mean GI (± standard error of the mean) of processed lentils ranged from 25 ± 3 (boiled) to 66 ± 6 (spray-dried); the GI of spray-dried lentils was significantly ( p < 0.05) higher than boiled, pureed, or roasted lentil. Overall, lentil-based food items all elicited significantly lower RGR compared to potato-based items (40 ± 3 vs. 73 ± 3%; p < 0.001). Apricot chicken, chicken pot pie, and lemony parsley soup had the highest overall acceptability corresponding to "like slightly" to "like moderately". Processing influenced the PPBG of lentils, but food items formulated from lentil puree significantly attenuated PPBG. Formulation was associated with significant differences in sensory attributes.
Wolever, Thomas M. S.; Hawke, Aileen; Zahradka, Peter; Aliani, Michel
2018-01-01
The consumption of pulses is associated with many health benefits. This study assessed post-prandial blood glucose response (PPBG) and the acceptability of food items containing green lentils. In human trials we: (i) defined processing methods (boiling, pureeing, freezing, roasting, spray-drying) that preserve the PPBG-lowering feature of lentils; (ii) used an appropriate processing method to prepare lentil food items, and compared the PPBG and relative glycemic responses (RGR) of lentil and control foods; and (iii) conducted consumer acceptability of the lentil foods. Eight food items were formulated from either whole lentil puree (test) or instant potato (control). In separate PPBG studies, participants consumed fixed amounts of available carbohydrates from test foods, control foods, or a white bread standard. Finger prick blood samples were obtained at 0, 15, 30, 45, 60, 90, and 120 min after the first bite, analyzed for glucose, and used to calculate incremental area under the blood glucose response curve and RGR; glycemic index (GI) was measured only for processed lentils. Mean GI (± standard error of the mean) of processed lentils ranged from 25 ± 3 (boiled) to 66 ± 6 (spray-dried); the GI of spray-dried lentils was significantly (p < 0.05) higher than boiled, pureed, or roasted lentil. Overall, lentil-based food items all elicited significantly lower RGR compared to potato-based items (40 ± 3 vs. 73 ± 3%; p < 0.001). Apricot chicken, chicken pot pie, and lemony parsley soup had the highest overall acceptability corresponding to “like slightly” to “like moderately”. Processing influenced the PPBG of lentils, but food items formulated from lentil puree significantly attenuated PPBG. Formulation was associated with significant differences in sensory attributes. PMID:29751679
Chassé, Michaël; English, Shane W; McIntyre, Lauralyn; Knoll, Greg; Shehata, Nadine; Forster, Alan; Wilson, Kumanan; van Walraven, Carl; Tinmouth, Alan; Fergusson, Dean A
2014-03-20
Optimal selection of blood donors is of paramount importance in ensuring the safety of blood products. The current selection process is concerned principally with the safety of the blood donor and the safety of the patient that receives the blood. Recent evidence suggests that the characteristics of the donor may affect transfusion outcomes for the recipient. We will conduct a systematic review of the association between major blood donor characteristics and red blood cell (RBC) transfusion outcomes. The primary objective is to assess the association of blood donor characteristics and the risk of adverse short-term and long-term clinical outcomes after RBC transfusion. We will search MEDLINE, EMBASE, Cochrane Central databases, as well as perform manual searches of top transfusion medical journals for prospective and retrospective studies. Study characteristics will be reported and the methodological quality of studies will be assessed. When appropriate, we will provide pooled odds ratio with 95% confidence intervals of the effect estimates, study clinical heterogeneity using pre-defined sensitivity and subgroup analyses, and study statistical heterogeneity using the I2 test. The results of this systematic review will provide an evidence base regarding the potential clinical effects of donor characteristics on transfusion recipients to better guide policy and clinical practice. The evidence gathered from this review will also identify strengths and weaknesses of published studies regarding donor characteristics and transfusion outcomes and will identify knowledge gaps to inform future research in this field of transfusion medicine. PROSPERO Registration Number: CRD42013006726.
NASA Astrophysics Data System (ADS)
Nawani, Jigna; Rixius, Julia; Neuhaus, Birgit J.
2016-08-01
Empirical analysis of secondary biology classrooms revealed that, on average, 68% of teaching time in Germany revolved around processing tasks. Quality of instruction can thus be assessed by analyzing the quality of tasks used in classroom discourse. This quasi-experimental study analyzed how teachers used tasks in 38 videotaped biology lessons pertaining to the topic 'blood and circulatory system'. Two fundamental characteristics used to analyze tasks include: (1) required cognitive level of processing (e.g. low level information processing: repetiition, summary, define, classify and high level information processing: interpret-analyze data, formulate hypothesis, etc.) and (2) complexity of task content (e.g. if tasks require use of factual, linking or concept level content). Additionally, students' cognitive knowledge structure about the topic 'blood and circulatory system' was measured using student-drawn concept maps (N = 970 students). Finally, linear multilevel models were created with high-level cognitive processing tasks and higher content complexity tasks as class-level predictors and students' prior knowledge, students' interest in biology, and students' interest in biology activities as control covariates. Results showed a positive influence of high-level cognitive processing tasks (β = 0.07; p < .01) on students' cognitive knowledge structure. However, there was no observed effect of higher content complexity tasks on students' cognitive knowledge structure. Presented findings encourage the use of high-level cognitive processing tasks in biology instruction.
Code of Federal Regulations, 2013 CFR
2013-10-01
... composite allograft (defined in this section). Blood vessels recovered from an organ donor during the... composite allograft means a body part: (1) That is vascularized and requires blood flow by surgical connection of blood vessels to function after transplantation; (2) Containing multiple tissue types; (3...
Code of Federal Regulations, 2014 CFR
2014-10-01
... composite allograft (defined in this section). Blood vessels recovered from an organ donor during the... composite allograft means a body part: (1) That is vascularized and requires blood flow by surgical connection of blood vessels to function after transplantation; (2) Containing multiple tissue types; (3...
Numerical simulation of isolation of cancer cells in a microfluidic chip
NASA Astrophysics Data System (ADS)
Djukic, T.; Topalovic, M.; Filipovic, N.
2015-08-01
Cancer is a disease that is characterized by the uncontrolled increase of numbers of cells. Circulating tumour cells (CTCs) are separated from the primary tumor, circulate in the bloodstream and form metastases. Circulating tumor cells can be identified in the blood of a patient by taking a blood sample. Microfluidic chips are a new technique that is used to isolate these cells from the blood sample. In this paper a numerical model is presented that is able to simulate the motion of individual cells through a microfluidic chip. The proposed numerical model gives very valuable insight into the processes happening within a microfluidic chip. The accuracy of the proposed model is compared with experimental results. The experimental setup that is described in literature is used to create identical geometrical domains and define simulation parameters. A good agreement of experimental and numerical results demonstrates that the proposed model can be successfully used to simulate complex behaviour of CTCs inside microfluidic chips.
Adverse reactions to blood donations: the READ project.
Garozzo, Giovanni; Crocco, Isabella; Giussani, Barbara; Martinucci, Annalisa; Monacelli, Stefano; Randi, Vanda
2010-01-01
In 2006 in Italy 2,404,267 donations of blood components were made by 1,539,454 donors; approximately 55% of the donations were collected directly by Transfusion Structures (TS), while about 45% were collected in Donation Centres managed by Associations and Federations of Donors. The aim of the READ (Rilevamento Eventi Avversi alla Donazione) project is to create a network of TS to test a standardised system for monitoring adverse events (AE) related to blood donations. Shared, standardised data collection forms, compatible with the forms produced by the ISBT-EHN, were prepared. Two types of form were used: (i) a form to collect data on single events (READ 1), to be used at the individual collection sites; (ii) a form for processing the data collected by each TS (READ 2). Between February and August 2008 six TS collected data related to the donation of 89,332 units of blood. Overall, 523 AE were recorded. The AE occurred in 0.59% of the donations. The mean duration of the symptoms was 17 minutes. Fifteen percent of the symptoms were related to the venipuncture (mainly haematomas) and 77% to vasovagal AE. The AE were defined severe (grade C) in 47 cases. The donations in which AE were recorded were completed in 81% of the cases; 59% of the AE did not require treatment. Three donors were monitored briefly (for less than 4 hours) in hospital. The use of standardised forms enabled the collection of data that could be analysed. Some problems related to the performance of the haemovigilance programme did, however, emerge: (i) organisational problems, (ii) limited sensitivity, (iii) inadequate training, and (iv) poorly defined responsibilities. These problems must be resolved at various levels: local, regional and national.
Sutton, N; Tracey, M C; Johnston, I D; Greenaway, R S; Rampling, M W
1997-05-01
A novel instrument has been developed to study the microrheology of erythrocytes as they flow through channels of dimensions similar to human blood capillaries. The channels are produced in silicon substrates using microengineering technology. Accurately defined, physiological driving pressures and temperatures are employed whilst precise, real-time image processing allows individual cells to be monitored continuously during their transit. The instrument characterises each cell in a sample of ca. 1000 in terms of its volume and flow velocity profile during its transit through a channel. The unique representation of the data in volume/velocity space provides new insight into the microrheological behaviour of blood. The image processing and subsequent data analysis enable the system to reject anomalous events such as multiple cell transits, thereby ensuring integrity of the resulting data. By employing an array of microfluidic flow channels we can integrate a number of different but precise and highly reproducible channel sizes and geometries within one array, thereby allowing multiple, concurrent isobaric measurements on one sample. As an illustration of the performance of the system, volume/velocity data sets recorded in a microfluidic device incorporating multiple channels of 100 microns length and individual widths ranging between 3.0 and 4.0 microns are presented.
Mascette, Alice M; Bernard, Gordon R; Dimichele, Donna; Goldner, Jesse A; Harrington, Robert; Harris, Paul A; Leeds, Hilary S; Pearson, Thomas A; Ramsey, Bonnie; Wagner, Todd H
2012-12-01
The National Heart, Lung, and Blood Institute (NHLBI) of the National Institutes of Health convened a working group in June 2011 to examine alternative institutional review board (IRB) models. The working group was held in response to proposed changes in the regulations for government-supported research and the proliferation of multicenter clinical trials where multiple individual reviews may be inefficient. Group members included experts in heart, lung, and blood research, research oversight, bioethics, health economics, regulations, and information technology (IT). The group discussed alternative IRB models, ethical concerns, metrics for evaluating IRBs, IT needs, and economic considerations. Participants noted research gaps in IRB best practices and in metrics. The group arrived at recommendations for process changes, such as defining specific IRB performance requirements in funding announcements, requiring funded researchers to use more efficient alternative IRB models, and developing IT systems to facilitate information sharing and collaboration among IRBs. Despite the success of the National Cancer Institute's central IRB (CIRB), the working group, concerned about the creation costs and unknown cost-efficiency of a new CIRB, and about the risk of shifting the burden of dealing with multiple IRBs from sponsors to research institutions, did not recommend the creation of an NHLBI-funded CIRB.
Alvarez-Corrales, Nancy; Ahmed, Raija K; Rodriguez, Carol A; Balaji, Kithiganahalli N; Rivera, Rebeca; Sompallae, Ramakrishna; Vudattu, Nalini K; Hoffner, Sven E; Zumla, Alimuddin; Pineda-Garcia, Lelany; Maeurer, Markus
2013-03-06
A better understanding of the quality of cellular immune responses directed against molecularly defined targets will guide the development of TB diagnostics and identification of molecularly defined, clinically relevant M.tb vaccine candidates. Recombinant proteins (n = 8) and peptide pools (n = 14) from M. tuberculosis (M.tb) targets were used to compare cellular immune responses defined by IFN-γ and IL-17 production using a Whole Blood Assay (WBA) in a cohort of 148 individuals, i.e. patients with TB + (n = 38), TB- individuals with other pulmonary diseases (n = 81) and individuals exposed to TB without evidence of clinical TB (health care workers, n = 29). M.tb antigens Rv2958c (glycosyltransferase), Rv2962c (mycolyltransferase), Rv1886c (Ag85B), Rv3804c (Ag85A), and the PPE family member Rv3347c were frequently recognized, defined by IFN-γ production, in blood from healthy individuals exposed to M.tb (health care workers). A different recognition pattern was found for IL-17 production in blood from M.tb exposed individuals responding to TB10.4 (Rv0288), Ag85B (Rv1886c) and the PPE family members Rv0978c and Rv1917c. The pattern of immune target recognition is different in regard to IFN-γ and IL-17 production to defined molecular M.tb targets in PBMCs from individuals frequently exposed to M.tb. The data represent the first mapping of cellular immune responses against M.tb targets in TB patients from Honduras.
A data driven nonlinear stochastic model for blood glucose dynamics.
Zhang, Yan; Holt, Tim A; Khovanova, Natalia
2016-03-01
The development of adequate mathematical models for blood glucose dynamics may improve early diagnosis and control of diabetes mellitus (DM). We have developed a stochastic nonlinear second order differential equation to describe the response of blood glucose concentration to food intake using continuous glucose monitoring (CGM) data. A variational Bayesian learning scheme was applied to define the number and values of the system's parameters by iterative optimisation of free energy. The model has the minimal order and number of parameters to successfully describe blood glucose dynamics in people with and without DM. The model accounts for the nonlinearity and stochasticity of the underlying glucose-insulin dynamic process. Being data-driven, it takes full advantage of available CGM data and, at the same time, reflects the intrinsic characteristics of the glucose-insulin system without detailed knowledge of the physiological mechanisms. We have shown that the dynamics of some postprandial blood glucose excursions can be described by a reduced (linear) model, previously seen in the literature. A comprehensive analysis demonstrates that deterministic system parameters belong to different ranges for diabetes and controls. Implications for clinical practice are discussed. This is the first study introducing a continuous data-driven nonlinear stochastic model capable of describing both DM and non-DM profiles. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Targeted disruption of deep-lying neocortical microvessels in rat using ultrashort laser pulses
NASA Astrophysics Data System (ADS)
Nishimura, Nozomi; Schaffer, Christopher B.; Friedman, Beth; Tsai, Philbert S.; Lyden, Patrick D.; Kleinfeld, David
2004-06-01
The study of neurovascular diseases such as vascular dementia and stroke require novel models of targeted vascular disruption in the brain. We describe a model of microvascular disruption in rat neocortex that uses ultrashort laser pulses to induce localized injury to specific targeted microvessels and uses two-photon microscopy to monitor and guide the photodisruption process. In our method, a train of high-intensity, 100-fs laser pulses is tightly focused into the lumen of a blood vessel within the upper 500 μm of cortex. Photodisruption induced by these laser pulses creates injury to a single vessel located at the focus of the laser, leaving the surrounding tissue intact. This photodisruption results in three modalities of localized vascular injury. At low power, blood plasma extravasation can be induced. The vessel itself remains intact, while serum is extravasated into the intercellular space. Localized ischemia caused by an intravascular clot results when the photodisruption leads to a brief disturbance of the vascular walls that initiates an endogenous clotting cascade. The formation of a localized thrombus stops the blood flow at the location of the photodisruption. A hemorrhage, defined as a large extravasation of blood including plasma and red blood cells, results when higher laser power is used. The targeted vessel does not remain intact.
Roliński, Jacek; Grywalska, Ewelina; Pyzik, Aleksandra; Dzik, Michał; Opoka-Winiarska, Violetta; Surdacka, Agata; Maj, Maciej; Burdan, Franciszek; Pirożyński, Michał; Grabarczyk, Piotr; Starosławska, Elżbieta
2018-04-20
Chronic active Epstein-Barr virus (EBV) disease (CAEBV) is defined as a severe, progressive lymphoproliferative disorder associated with active EBV infection persisting longer than 6 months and developing in patients without recognised immunodeficiency. Rarely, interstitial pneumonitis (IP) occurs as a serious complication in CAEBV patients. The standard therapeutic regimen for IP in CAEBV has not yet been defined. Although interferon alpha (IFN-alpha) is known to suppress viral DNA replication by affecting its basal promoter activation process, it is rarely used in CAEBV patients. A 22-year-old Caucasian woman, diagnosed with CAEBV 1.5 years earlier, was admitted to the Immunology Clinic due to a 4-week history of productive cough, fever and general weakness. Cultures of blood, urine and sputum were negative, but EBV DNA copies were found in the sputum, whole blood, isolated peripheral blood lymphocytes as well as in the blood plasma. Cytokine assessment in peripheral blood revealed the lack of IFN-alpha synthesis. Disseminated maculate infiltrative areas in both lungs were observed on a computed tomography (CT) chest scan. The patient was not qualified for the allogeneic hematopoietic stem cell transplantation (allo-HSCT) due to the risk of immunosuppression-related complications of infectious IP. Inhaled (1.5 million units 3 times a day) and subcutaneous (6 million units 3 times a week) IFN-alpha was implemented. To the best of our knowledge, this was the first documented use of inhaled IFN-alpha in a patient with CAEBV and concomitant IP. Patient's status has improved, and she was eventually qualified to allo-HSCT with reduced conditioning. Currently, the patient feels well, no EBV was detected and further regression of pulmonary changes was documented. CAEBV should be considered in patients who present with interstitial lung infiltration and involvement of other organs. Although more promising results have been obtained with allo-HSCT, inhaled IFN-alpha may also be a therapeutic option in patients with CAEBV and a concomitant IP.
Gianassi, S; Bisin, S; Bindi, B; Spitaleri, I; Bambi, F
2010-01-01
The collection and handling of hematopoietic stem cells (HSCs) must meet high quality requirements. An integrated Quality Risk Management can help to identify and contain potential risks related to HSC production. Risk analysis techniques allow one to "weigh" identified hazards, considering the seriousness of their effects, frequency, and detectability, seeking to prevent the most harmful hazards. The Hazard Analysis Critical Point, recognized as the most appropriate technique to identify risks associated with physical, chemical, and biological hazards for cellular products, consists of classifying finished product specifications and limits of acceptability, identifying all off-specifications, defining activities that can cause them, and finally establishing both a monitoring system for each Critical Control Point and corrective actions for deviations. The severity of possible effects on patients, as well as the occurrence and detectability of critical parameters, are measured on quantitative scales (Risk Priority Number [RPN]). Risk analysis was performed with this technique on manipulation process of HPC performed at our blood center. The data analysis showed that hazards with higher values of RPN with greater impact on the process are loss of dose and tracking; technical skills of operators and manual transcription of data were the most critical parameters. Problems related to operator skills are handled by defining targeted training programs, while other critical parameters can be mitigated with the use of continuous control systems. The blood center management software was completed by a labeling system with forms designed to be in compliance with standards in force and by starting implementation of a cryopreservation management module. Copyright 2010 Elsevier Inc. All rights reserved.
Abdalla, Marwah; Booth, John N.; Seals, Samantha R.; Spruill, Tanya M.; Viera, Anthony J.; Diaz, Keith M.; Sims, Mario; Muntner, Paul; Shimbo, Daichi
2016-01-01
Masked hypertension, defined as non-elevated clinic blood pressure and elevated out-of-clinic blood pressure may be an intermediary stage in the progression from normotension to hypertension. We examined the associations of out-of-clinic blood pressure and masked hypertension using ambulatory blood pressure monitoring with incident clinic hypertension in the Jackson Heart Study, a prospective cohort of African Americans. Analyses included 317 participants with clinic blood pressure <140/90mmHg, complete ABPM, who were not taking antihypertensive medication at baseline in 2000–2004. Masked daytime hypertension was defined as mean daytime blood pressure ≥135/85mmHg; masked nighttime hypertension as mean nighttime blood pressure ≥120/70mmHg; and masked 24-hour hypertension as mean 24-hour blood pressure ≥130/80mmHg. Incident clinic hypertension, assessed at study visits in 2005–2008 and 2009–2012, was defined as the first visit with clinic systolic/diastolic blood pressure ≥140/90mmHg or antihypertensive medication use. During a median follow-up of 8.1 years, there were 187 (59.0%) incident cases of clinic hypertension. Clinic hypertension developed in 79.2% and 42.2% of participants with and without any masked hypertension, 85.7% and 50.4% with and without masked daytime hypertension, 79.9% and 43.7% with and without masked nighttime hypertension and 85.7% and 48.2% with and without masked 24-hour hypertension, respectively. Multivariable-adjusted hazard ratios (95% CI) of incident clinic hypertension for any masked hypertension and masked daytime, nighttime, and 24-hour hypertension were 2.13 (1.51–3.02), 1.79 (1.24–2.60), 2.22 (1.58–3.12), and 1.91 (1.32–2.75), respectively. These findings suggest that ambulatory blood pressure monitoring can identify African Americans at increased risk for developing clinic hypertension. PMID:27185746
Effect of electric charge on the adhesion of human blood platelets.
Lowkis, B; Szymonowicz, M
1993-01-01
The paper presents the results of research into the effect of the size and depth of the implanted electric charge on the adhesion of human blood platelets. The experiments were carried out on polyethylene terephthalate PET foil of 36 microns thickness. The electret formation process was carried out in an electron-beam device. The electrization conditions were such that electrets with the excess electric charge accumulated at various depths were obtained. The selection of conditions was verified by investigating the space charge distribution with the use of the virtual electrode method. The microscopic observation of non-electrified foils and electrets as well as the quantitative examination of the adhesion of human blood platelets has explicitly confirmed the positive influence of the electret effect on the thrombogenesis of PET foil. This made it possible to define the optimum electrization conditions. The research has additionally indicated that the relationship between the amount of adherent blood platelets and the size of the electric charge is not a simple relation of the kind: the larger negative charge, the more thrombogenic material. The decisive and positive effect of the space charge has been confirmed by analysing the effectiveness of the surface and space charge.
Blood bank on-call physician's experiences at a large university medical center.
Bryant, Barbara J; Alperin, Jack B; Indrikovs, Alexander J
2005-01-01
The responsibilities of the blood bank on-call physician (blood bank physician from here on) encompass many aspects of transfusion medicine and physician education. This physician is available 24 hours a day to address any issues concerning the collection and transfusion of blood and blood components. The purpose of this study was to identify and categorize the issues that may confront a blood bank physician. Each call received over a 4-month period was logged and the resolution documented. The calls were grouped into five categories: donor issues, therapeutic procedure issues, patient issues, physician education issues, and requests for blood components not meeting previously defined transfusion guidelines. The blood bank physician received 224 calls during the study period. To resolve each issue, an additional 1 to 14 telephone calls were needed to gather further information. Number of calls by category were donor issues, 20 (8.9%); therapeutic procedure issues, 9 (4.0%); patient issues, 4 (1.8%); physician education issues, 33 (14.7%); and requests for blood components not meeting previously defined transfusion guidelines, 158 (70.6%). Requests for blood components were denied in 39.8 percent of the cases not meeting guidelines. Other forms of therapy were warranted in 20.9 percent of the cases. This study revealed that 85.3 percent of the calls referred to the blood bank physician related to physician education and the appropriateness of blood component orders. These results emphasize the need for ongoing education of medical staff in transfusion medicine issues.
Is Low Blood Glucose (Hypoglycemia) Dangerous?
... for brain damage related to repeated severe hypoglycemia. Guidelines for managing hypoglycemia Recognize symptoms (physical, emotional, mental) ... not risen above the target levels defined above . Guidelines for safe driving Check blood glucose levels before ...
Bartoszko, Justyna; Vorobeichik, Leon; Jayarajah, Mohandas; Karkouti, Keyvan; Klein, Andrew A; Lamy, Andre; Mazer, C David; Murphy, Mike; Richards, Toby; Englesakis, Marina; Myles, Paul S; Wijeysundera, Duminda N
2017-06-30
'Standardised Endpoints for Perioperative Medicine' (StEP) is an international collaboration undertaking development of consensus-based consistent definitions for endpoints in perioperative clinical trials. Inconsistency in endpoint definitions can make interpretation of trial results more difficult, especially if conflicting evidence is present. Furthermore, this inconsistency impedes evidence synthesis and meta-analyses. The goals of StEP are to harmonise definitions for clinically meaningful endpoints and specify standards for endpoint reporting in clinical trials. To help inform this endeavour, we aim to conduct a scoping review to systematically characterise the definitions of clinically important endpoints in the existing published literature on perioperative blood loss and transfusion. The scoping review will be conducted using the widely adopted framework developed by Arksey and O'Malley, with modifications from Levac. We refined our methods with guidance from research librarians as well as researchers and clinicians with content expertise. The electronic literature search will involve several databases including Medline, PubMed-not-Medline and Embase. Our review has three objectives, namely to (1) identify definitions of significant blood loss and transfusion used in previously published large perioperative randomised trials; (2) identify previously developed consensus-based definitions for significant blood loss and transfusion in perioperative medicine and related fields; and (3) describe the association between different magnitudes of blood loss and transfusion with postoperative outcomes. The multistage review process for each question will involve two reviewers screening abstracts, reading full-text articles and performing data extraction. The abstracted data will be organised and subsequently analysed in an iterative process. This scoping review of the previously published literature does not require research ethics approval. The results will be used to inform a consensus-based process to develop definitions of clinically important perioperative blood loss and transfusion. The results of the scoping review will be published in a peer-reviewed scientific journal. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Fresh Whole Blood Use for Hemorrhagic Shock: Preserving Benefit While Avoiding Complications
2012-10-01
coagulation factor deficiency), and improved blood bank economics.1–3 However, component usage in austere settings (developing world and combat) is often...limited by storage requirements for blood products (refrig- eration for red blood cells [RBCs], room temperature with agitation for platelets [PLTs...red blood cell (RBC) or plasma product inven- tory” (Ref. 1 in Table 1). Most civilian institutions define it as fresh if it is stored for 48 hours
Dynamics of blood flow in a microfluidic ladder network
NASA Astrophysics Data System (ADS)
Maddala, Jeevan; Zilberman-Rudenko, Jevgenia; McCarty, Owen
The dynamics of a complex mixture of cells and proteins, such as blood, in perturbed shear flow remains ill-defined. Microfluidics is a promising technology for improving the understanding of blood flow under complex conditions of shear; as found in stent implants and in tortuous blood vessels. We model the fluid dynamics of blood flow in a microfluidic ladder network with dimensions mimicking venules. Interaction of blood cells was modeled using multiagent framework, where cells of different diameters were treated as spheres. This model served as the basis for predicting transition regions, collision pathways, re-circulation zones and residence times of cells dependent on their diameters and device architecture. Based on these insights from the model, we were able to predict the clot formation configurations at various locations in the device. These predictions were supported by the experiments using whole blood. To facilitate platelet aggregation, the devices were coated with fibrillar collagen and tissue factor. Blood was perfused through the microfluidic device for 9 min at a physiologically relevant venous shear rate of 600 s-1. Using fluorescent microscopy, we observed flow transitions near the channel intersections and at the areas of blood flow obstruction, which promoted larger thrombus formation. This study of integrating model predictions with experimental design, aids in defining the dynamics of blood flow in microvasculature and in development of novel biomedical devices.
21 CFR 640.60 - Source Plasma.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...
21 CFR 640.60 - Source Plasma.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...
21 CFR 640.60 - Source Plasma.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...
21 CFR 640.60 - Source Plasma.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...
Hozawa, Atsushi; Ohkubo, Takayoshi; Obara, Taku; Metoki, Hirohito; Kikuya, Masahiro; Asayama, Kei; Totsune, Kazuhito; Hashimoto, Junichiro; Hoshi, Haruhisa; Arai, Yumiko; Satoh, Hiroshi; Hosokawa, Toru; Imai, Yutaka
2006-11-01
To explore the effect of personality on screening blood pressures measured in clinical settings and home blood pressure measurements. From 1997 to 1999, 699 participants underwent screening and home blood pressure measurements and completed the Japanese version of the short-form Eysenck personality questionnaire. An increased screening blood pressure was defined as screening blood pressure > or = 140/90 mmHg and an increased home blood pressure was defined as home blood pressure > or = 135/85 mmHg. Participants with lower extroversion scores (i.e., introversion) showed a greater difference between screening and home systolic blood pressure. The association between introversion and differences was statistically significant, even after adjustment for other possible factors (younger age, female, wide screening pulse pressure, never smoked, and no antihypertensive medication). The adjusted means of SBP differences were 7.3 and 4.4 mmHg among the lowest and highest extroversion quartiles, respectively (P for trend = 0.02). Other personality scores (psychoticism or neuroticism) were not associated with screening and home blood pressure differences. The incorporation of an extroversion score in the basic model consisting of the above factors that affected the difference between screening and home blood pressure slightly improved the prediction of a high home blood pressure. The area under the receiver operating characteristic curve increased by 0.037 among participants with high screening blood pressure and 0.006 for those with normal screening blood pressure compared with the basic model. Physicians may need to be aware of 'introverted' patients who have high blood pressure in clinic settings, because they have the potential for 'white-coat' hypertension.
[Liability for hepatitis after blood transfusion (author's transl)].
Fiedler, H; Hackethal, B
1980-01-01
1) Only a very limited amount of all cases of so-called "post-transfusion-hepatitis" (pth) is really due to infectivity of the transfused blood. Regardless of the mostly unknown true source of the infection, the occurrence of "pth" for itself does not qualify the recipient and/or his illness-insurance company for a legitimate action for damages against the blood bank under current West Germany Federal Law. 2) All West German blood banks are obliged by Federal Law to insure themselves against strictly defined damage claims. Their damage-insurance companies are not entitled to pay compensations to the illness-insurance companies of any victim of "pth" without meticulous investigation of the exact circumstances if expenses exceeding the legally defined limitations are included in the premium of damage-insurance charged to the blood banks. 3)Since nearly all inhabitants of West Germany are legally or voluntarily insured against illness, compensations paid by damage-insurance companies to illness-insurance companies are no appropriate means for any cost containment of the latter: The blood banks have no other choice than to calculate the additional premium costs into the costs of the blood units to be debitted to the illness-insurance companies.
Terminal echocardiographic findings during death process in man and dogs.
Wang, F S; Lien, W P; Fong, T E
1991-01-01
Serial echocardiographic imaging was performed to assess terminal mechanical changes of cardiac chambers and valves, as well as sequential echocardiographic features of blood stasis, inside the heart after mechanical asystole in 7 hospitalized adults who died without apparent cardiac disease and in 7 experimental dogs sacrificed by a means of asphyxia. Marked reduction of wall motion became manifest shortly after the electrocardiograms had generated into a slow junctional rhythm with intraventricular conduction defect, an idioventricular rhythm, or an extreme sinus bradycardia. Total cessation of cardiac wall and valve motion followed; the aortic valve remained closed, with mitral and tricuspid valves semiopen after total cardiac asystole. Liquid whole blood inside the heart became echogenic shortly before mechanical asystole had approached, and homogenous echogenicity usually first appeared on the right side of the heart. As the death process progressed and total asystole persisted, the acoustic intensity of the intracavitary echoes increased, tending to form amorphous masses, with some showing rather well-defined borders. Such echocardiographic features were noted to indicate red thrombi in experimental dogs. The cardiac dimensions (left ventricle and aorta) decreased after total cardiac asystole.
Role of proteoglycans in neuro-inflammation and central nervous system fibrosis.
Heindryckx, Femke; Li, Jin-Ping
2018-01-31
Fibrosis is defined as the thickening and scarring of connective tissue, usually as a consequence of tissue damage. The central nervous system (CNS) is special in the sense that fibrogenic cells are restricted to vascular and meningeal areas. Inflammation and the disruption of the blood-brain barrier can lead to the infiltration of fibroblasts and trigger fibrotic response. While the initial function of the fibrotic tissue is to restore the blood-brain barrier and to limit the site of injury, it also demolishes the structure of extracellular matrix and impedes the healing process by producing inhibitory molecules and forming a physical and biochemical barrier that prevents axon regeneration. As a major constituent in the extracellular matrix, proteoglycans participate in the neuro-inflammation, modulating the fibrotic process. In this review, we will discuss the pathophysiology of fibrosis during acute injuries of the CNS, as well as during chronic neurodegenerative conditions such as Alzheimer's disease, Parkinson's disease, multiple sclerosis and age-related neurodegeneration with focus on the functional roles of proteoglycans. Copyright © 2017 International Society of Matrix Biology. Published by Elsevier B.V. All rights reserved.
[Blood pressure targets : The lower the better does not suit all].
Hoffmann, U
2018-04-01
The systolic blood pressure intervention trial (SPRINT) published in 2015 has opened up new discussions on whether a lower blood pressure target as recommended by the current guidelines would be better for some patient groups. To review patient groups in which lower blood pressure targets would not be better. The results of SPRINT, its post-hoc and subgroup analyses, other studies and newer studies, as well as metaanalyses on the topic of blood pressure targets are reviewed and discussed. Studies with patients excluded from the SPRINT study were also analysed. The current international guidelines and recommendations of the Deutsche Hochdruckliga e. V. DHL® are included. Blood pressure monitoring methods differed considerably in the previously published studies. The low blood pressure value in SPRINT was mainly achieved due to the unusual method of blood pressure monitoring used and, as such, cannot be compared with blood pressure values in other studies. Based on current evidence, "the lower the better" should not be recommended in the following patient groups: older patients, in particular infirm older patients, patients with diabetes, patients without coronary heart disease or with low cardiovascular risk. When determining a blood pressure target, the method of blood pressure monitoring should be defined. A lower blood pressure target has been shown to be better in some well defined patient groups. However, adverse events due to antihypertensive medications should always be taken into account. Given the multiple exclusion criteria in trials and the results of many studies, "new" lower blood pressure targets could not be recommended in a large population of patients.
Munakata, Masanori
2018-05-29
High blood pressure is the most significant risk factor of cardiovascular and cerebrovascular diseases worldwide. Blood pressure and its variability are recognized as risk factors. Thus, hypertension control should focus not only on maintaining optimal levels but also on achieving less variability in blood pressure. Psychosocial stress is known to contribute to the development and worsening of hypertension. Stress is perceived by the brain and induces neuroendocrine responses in either a rapid or long-term manner. Moreover, endothelial dysfunction and inflammation might be further involved in the modulation of blood pressure elevation associated with stress. White-coat hypertension, defined as high clinic blood pressure but normal out-of-office blood pressure, is the most popular stress-related blood pressure response. Careful follow-up is necessary for this type of hypertensive patients because some show organ damage or a worse prognosis. On the other hand, masked hypertension, defined as high out-of-office blood pressure but normal office blood pressure, has received considerable interest as a poor prognostic condition. The cause of masked hypertension is complex, but evidence suggests that chronic stress at the workplace or home could be involved. Chronic psychological stress could be associated with distorted lifestyle and mental distress as well as long-lasting allostatic load, contributing to the maintenance of blood pressure elevation. Stress issues are common in patients in modern society. Considering psychosocial stress as the pathogenesis of blood pressure elevation is useful for achieving an individual-focused approach and 24-h blood pressure control.
Kelishadi, Roya; Bahreynian, Maryam; Heshmat, Ramin; Motlagh, Mohammad Esmail; Djalalinia, Shirin; Naji, Fatemeh; Ardalan, Gelayol; Asayesh, Hamid; Qorbani, Mostafa
2016-02-01
The aim of this study was to propose a simple practical diagnostic criterion for pre-hypertension (pre-HTN) and hypertension (HTN) in the pediatric age group. This study was conducted on a nationally representative sample of 14,880 students, aged 6-18 years. HTN and pre-HTN were defined as systolic blood pressure (SBP) and/or diastolic blood pressure (DBP) ≥ 95 and 90-95th percentile for age, gender, and height, respectively. By using the area under the curve (AUC) of the receiver operator characteristic curves, we estimated the diagnostic accuracy of two indexes of SBP-to-height ratio (SBPHR) and DBP-to-height (DBPHR) to define pre-HTN and HTN. Overall, SBPHR performed relatively well in classifying subjects to HTN (AUC 0.80-0.85) and pre-HTN (AUC 0.84-0.90). Likewise, DBPHR performed relatively well in classifying subjects to HTN (AUC 0.90-0.97) and pre-HTN (AUC 0.70-0.83). Two indexes of SBPHR and DBPHR are considered as valid, simple, inexpensive, and accurate tools to diagnose pre-HTN and HTN in pediatric age group.
Blood doping: risks to athletes' health and strategies for detection.
Oliveira, Carolina Dizioli Rodrigues de; Bairros, André Valle de; Yonamine, Mauricio
2014-07-01
Blood doping has been defined as the misuse of substances or certain techniques to optimize oxygen delivery to muscles with the aim to increase performance in sports activities. It includes blood transfusion, administration of erythropoiesis-stimulating agents or blood substitutes, and gene manipulations. The main reasons for the widespread use of blood doping include: its availability for athletes (erythropoiesis-stimulating agents and blood transfusions), its efficiency in improving performance, and its difficult detection. This article reviews and discusses the blood doping substances and methods used for in sports, the adverse effects related to this practice, and current strategies for its detection.
Yoshimatsu, Aya; Hoshi, Takuo; Nishikawa, Masashi; Aya, Daisuke; Ueda, Hiroshi; Yokouchi, Takako; Tanaka, Makoto
2013-08-01
We report a B Rh negative patient undergoing total pelvic exenteration, who received both ABO and Rh incompatible packed red blood cells in an emergency situation. After this experience, we revised the manual of emergency blood transfusion. We defined level of severity to share information with surgeon, nurses, anesthesiologists and the member of the blood center. We changed anesthesia information management system for showing blood type including Duffy blood group system and checking out whether we can transfuse Rh positive blood to Rh negative patient in an emergency situation at the timeout of surgery.
Lambert, Thomas; Nahler, Alexander; Rohla, Miklos; Reiter, Christian; Grund, Michael; Kammler, Jürgen; Blessberger, Hermann; Kypta, Alexander; Kellermair, Jörg; Schwarz, Stefan; Starnawski, Jennifer A; Lichtenauer, Michael; Weiss, Thomas W; Huber, Kurt; Steinwender, Clemens
2016-10-01
Defining an adequate endpoint for renal denervation trials represents a major challenge. A high inter-individual and intra-individual variability of blood pressure levels as well as a partial or total non-adherence on antihypertensive drugs hamper treatment evaluations after renal denervation. Blood pressure measurements at a single point in time as used as primary endpoint in most clinical trials on renal denervation, might not be sufficient to discriminate between patients who do or do not respond to renal denervation. We compared the traditional responder classification (defined as systolic 24-hour blood pressure reduction of -5mmHg six months after renal denervation) with a novel definition of an ideal respondership (based on a 24h blood pressure reduction at no point in time, one, or all follow-up timepoints). We were able to re-classify almost a quarter of patients. Blood pressure variability was substantial in patients traditionally defined as responders. On the other hand, our novel classification of an ideal respondership seems to be clinically superior in discriminating sustained from pseudo-response to renal denervation. Based on our observations, we recommend that the traditional response classification should be reconsidered and possibly strengthened by using a composite endpoint of 24h-BP reductions at different follow-up-visits. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ono, Shigeshi; Lam, Stella; Nagahara, Makoto; Hoon, Dave S. B.
2015-01-01
An increasing number of studies have focused on circulating microRNAs (cmiRNA) in cancer patients’ blood for their potential as minimally-invasive biomarkers. Studies have reported the utility of assessing specific miRNAs in blood as diagnostic/prognostic biomarkers; however, the methodologies are not validated or standardized across laboratories. Unfortunately, there is often minimum limited overlap in techniques between results reported even in similar type studies on the same cancer. This hampers interpretation and reliability of cmiRNA as potential cancer biomarkers. Blood collection and processing, cmiRNA extractions, quality and quantity control of assays, defined patient population assessment, reproducibility, and reference standards all affect the cmiRNA assay results. To date, there is no reported definitive method to assess cmiRNAs. Therefore, appropriate and reliable methodologies are highly necessary in order for cmiRNAs to be used in regulated clinical diagnostic laboratories. In this review, we summarize the developments made over the past decade towards cmiRNA detection and discuss the pros and cons of the assays. PMID:26512704
Yoshida, Ryu; Murray, Martha M.
2012-01-01
Use of platelet-rich plasma (PRP) has shown promise in various orthopaedic applications, including treatment of anterior cruciate ligament (ACL) injuries. However, various components of blood, including peripheral blood mononuclear cells (PBMCs), are removed in the process of making PRP. It is yet unknown whether these PBMCs have a positive or negative effect on fibroblast behavior. To begin to define the effect of PBMCs on ACL fibroblasts, ACL fibroblasts were cultured on three-dimensional collagen scaffolds for 14 days with and without PBMCs. ACL fibroblasts exposed to PBMCs showed increased type I and type III procollagen gene expression, collagen protein expression, and cell proliferation when the cells were cultured in the presence of platelets and plasma. However, addition of PBMCs to cells cultured without the presence of platelets had no effect. The increase in collagen gene and protein expression was accompanied by an increase in IL-6 expression by the PBMCs with exposure to the platelets. Our results suggest that the interaction between platelets and PBMCs leads to an IL-6 mediated increase in collagen expression by ACL fibroblasts. PMID:22767425
SPAKling insight into blood pressure regulation
Castañeda-Bueno, María; Gamba, Gerardo
2010-01-01
Arterial hypertension is one of the most important health problems in industrialized cities. Blood pressure levels are influenced by renal salt handling and salt reabsorption in the kidney. In this Closeup, Castañeda-Bueno and Gamba discuss the work from Alessi and coworkers on the in vivo roles of the SPAK kinase in defining blood pressure levels. PMID:20112249
21 CFR 640.60 - Source Plasma.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Source Plasma. 640.60 Section 640.60 Food and Drugs... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood collected by...
Cankovic, Milena; Varney, Ruan C.; Whiteley, Lisa; Brown, Ron; D'Angelo, Rita; Chitale, Dhananjay; Zarbo, Richard J.
2009-01-01
Accurate and timely molecular test results play an important role in patient management; consequently, there is a customer expectation of short testing turnaround times. Baseline data analysis revealed that the greatest challenge to timely result generation occurred in the preanalytic phase of specimen collection and transport. Here, we describe our efforts to improve molecular testing turnaround times by focusing primarily on redesign of preanalytic processes using the principles of LEAN production. Our goal was to complete greater than 90% of the molecular tests in less than 3 days. The project required cooperation from different laboratory disciplines as well as individuals outside of the laboratory. The redesigned processes involved defining and standardizing the protocols and approaching blood and tissue specimens as analytes for molecular testing. The LEAN process resulted in fewer steps, approaching the ideal of a one-piece flow for specimens through collection/retrieval, transport, and different aspects of the testing process. The outcome of introducing the LEAN process has been a 44% reduction in molecular test turnaround time for tissue specimens, from an average of 2.7 to 1.5 days. In addition, extending LEAN work principles to the clinician suppliers has resulted in a markedly increased number of properly collected and shipped blood specimens (from 50 to 87%). These continuous quality improvements were accomplished by empowered workers in a blame-free environment and are now being sustained with minimal management involvement. PMID:19661386
Generation of Functional Blood Vessels from a Single c-kit+ Adult Vascular Endothelial Stem Cell
Fang, Shentong; Wei, Jing; Pentinmikko, Nalle; Leinonen, Hannele; Salven, Petri
2012-01-01
In adults, the growth of blood vessels, a process known as angiogenesis, is essential for organ growth and repair. In many disorders including cancer, angiogenesis becomes excessive. The cellular origin of new vascular endothelial cells (ECs) during blood vessel growth in angiogenic situations has remained unknown. Here, we provide evidence for adult vascular endothelial stem cells (VESCs) that reside in the blood vessel wall endothelium. VESCs constitute a small subpopulation within CD117+ (c-kit+) ECs capable of undergoing clonal expansion while other ECs have a very limited proliferative capacity. Isolated VESCs can produce tens of millions of endothelial daughter cells in vitro. A single transplanted c-kit-expressing VESC by the phenotype lin−CD31+CD105+Sca1+CD117+ can generate in vivo functional blood vessels that connect to host circulation. VESCs also have long-term self-renewal capacity, a defining functional property of adult stem cells. To provide functional verification on the role of c-kit in VESCs, we show that a genetic deficit in endothelial c-kit expression markedly decreases total colony-forming VESCs. In vivo, c-kit expression deficit resulted in impaired EC proliferation and angiogenesis and retardation of tumor growth. Isolated VESCs could be used in cell-based therapies for cardiovascular repair to restore tissue vascularization after ischemic events. VESCs also provide a novel cellular target to block pathological angiogenesis and cancer growth. PMID:23091420
O'Mara, Michael S; Hayetian, Fernando; Slater, Harvey; Goldfarb, I William; Tolchin, Eric; Caushaj, Philip F
2005-08-01
Blood loss and high rates of transfusion in burn centers remains an area of ongoing concern. Blood use brings the risk of infection, adverse reaction, and immunosuppression. A protocol to reduce blood loss and blood use was implemented. Analysis included 3-year periods before and after institution of the protocol. All patients were transfused for a hemoglobin below 8.0 gm/dL. Operations per admission did not change during the two time periods (0.78 in each). Overall units transfused per operation decreased from 1.56+/-0.06 to 1.25+/-0.14 units after instituting the protocol (p<0.05). Also, units transfused per admission decreased from 1.21+/-0.15 to 0.96+/-0.06 units of blood (p<0.05). This was noticed particularly in burns of less than 20% surface area, declining from 386 to 46 units after protocol institution, from 0.37 to 0.04 units per admission, and from 0.79 to 0.08 units per operation in this group of smallest burns. There was no change noted in the larger burns. This study suggests that a defined protocol of hemostasis, technique, and transfusion trigger should be implemented in the process of burn excision and grafting. This will help especially those patients with the smallest burns, essentially eliminating transfusion need in that group.
Vaquier, C; Legrand, D; Caldani, C
2009-05-01
Since 1985, a Council Resolution defines a new approach to technical harmonization and standards. The directives resulting from this new approach establish the essential safety requirements with which products put on the market must conform, and which should therefore enjoy free movement throughout the European Union, owing to a presumption of conformity. However, if the manufacturer is responsible for the conformity of its product in terms of safety, it is the end-user who must make sure that its requirements for a specific use or a considered application are satisfied and that the product meets its needs. It is the objective of the procedure of validation, which calls upon protocols of qualification intended to show the aptitude of a material, a system, a device, of an installation, to meet the requirements of specified quality and safety. This concept of qualification applies to the data-processing software of the hospital blood banks. Only the stage of operational qualification will be developed here. It involves scenarios made up of test files which make it possible to check the electronic data interchanges between the hospital blood bank and the blood establishment (transmission of the results of analysis, transmission of the data of traceability), as well as the functions of assistance to the issuing of the labile blood products.
Light scattering method to measure red blood cell aggregation during incubation
NASA Astrophysics Data System (ADS)
Grzegorzewski, B.; Szołna-Chodór, A.; Baryła, J.; DreŻek, D.
2018-01-01
Red blood cell (RBC) aggregation can be observed both in vivo as well as in vitro. This process is a cause of alterations of blood flow in microvascular network. Enhanced RBC aggregation makes oxygen and nutrients delivery difficult. Measurements of RBC aggregation usually give a description of the process for a sample where the state of a solution and cells is well-defined and the system reached an equilibrium. Incubation of RBCs in various solutions is frequently used to study the effects of the solutions on the RBC aggregation. The aggregation parameters are compared before and after incubation while the detailed changes of the parameters during incubation remain unknown. In this paper we have proposed a method to measure red blood cell aggregation during incubation based on the well-known technique where backscattered light is used to assess the parameters of the RBC aggregation. Couette system consisting of two cylinders is adopted in the method. The incubation is observed in the Couette system. In the proposed method following sequence of rotations is adapted. Two minutes rotation is followed by two minutes stop. In this way we have obtained a time series of back scattered intensity consisting of signals respective for disaggregation and aggregation. It is shown that the temporal changes of the intensity manifest changes of RBC aggregation during incubation. To show the ability of the method to assess the effect of incubation time on RBC aggregation the results are shown for solutions that cause an increase of RBC aggregation as well as for the case where the aggregation is decreased.
Davis, Rodeina; Geiger, Bradley; Gutierrez, Alfonso; Heaser, Julie; Veeramani, Dharmaraj
2009-07-01
Radio frequency identification (RFID) can be a key enabler for enhancing productivity and safety of the blood product supply chain. This article describes a systematic approach developed by the RFID Blood Consortium for a comprehensive feasibility and impact assessment of RFID application in blood centre operations. Our comprehensive assessment approach incorporates process-orientated and technological perspectives as well as impact analysis. Assessment of RFID-enabled process redesign is based on generic core processes derived from the three participating blood centres. The technological assessment includes RFID tag readability and performance evaluation, testing of temperature and biological effects of RF energy on blood products, and RFID system architecture design and standards. The scope of this article is limited to blood centre processes (from donation to manufacturing/distribution) for selected mainstream blood products (red blood cells and platelets). Radio frequency identification can help overcome a number of common challenges and process inefficiencies associated with identification and tracking of blood products. High frequency-based RFID technology performs adequately and safely for red blood cell and platelet products. Productivity and quality improvements in RFID-enabled blood centre processes can recoup investment cost in a 4-year payback period. Radio frequency identification application has significant process-orientated and technological implications. It is feasible and economically justifiable to incorporate RFID into blood centre processes.
In-vivo cell tracking to quantify endothelial cell migration during zebrafish angiogenesis
NASA Astrophysics Data System (ADS)
Menon, Prahlad G.; Rochon, Elizabeth R.; Roman, Beth L.
2016-03-01
The mechanism of endothelial cell migration as individual cells or collectively while remaining an integral component of a functional blood vessel has not been well characterized. In this study, our overarching goal is to define an image processing workflow to facilitate quantification of how endothelial cells within the first aortic arch and are proximal to the zebrafish heart behave in response to the onset of flow (i.e. onset of heart beating). Endothelial cell imaging was conducted at this developmental time-point i.e. ~24-28 hours post fertilization (hpf) when flow first begins, using 3D+time two-photon confocal microscopy of a live, wild-type, transgenic, zebrafish expressing green fluorescent protein (GFP) in endothelial cell nuclei. An image processing pipeline comprised of image signal enhancement, median filtering for speckle noise reduction, automated identification of the nuclei positions, extraction of the relative movement of nuclei between consecutive time instances, and finally tracking of nuclei, was designed for achieving the tracking of endothelial cell nuclei and the identification of their movement towards or away from the heart. Pilot results lead to a hypothesis that upon the onset of heart beat and blood flow, endothelial cells migrate collectively towards the heart (by 21.51+/-10.35 μm) in opposition to blood flow (i.e. subtending 142.170+/-21.170 with the flow direction).
Mortier, Virginie; Vancoillie, Leen; Dauwe, Kenny; Staelens, Delfien; Demecheleer, Els; Schauvliege, Marlies; Dinakis, Sylvie; Van Maerken, Tom; Dessilly, Géraldine; Ruelle, Jean; Verhofstede, Chris
2017-10-24
Pre-analytical sample processing is often overlooked as a potential cause of inaccurate assay results. Here we demonstrate how plasma, extracted from standard EDTA-containing blood collection tubes, may contain traces of blood cells consequently resulting in a false low-level HIV-1 viral load when using Roche Cobas HIV-1 assays. The presence of human DNA in Roche Cobas 4800 RNA extracts and in RNA extracts from the Abbott HIV-1 RealTime assay was assessed by quantifying the human albumin gene by means of quantitative PCR. RNA was extracted from plasma samples before and after an additional centrifugation and tested for viral load and DNA contamination. The relation between total DNA content and viral load was defined. Elevated concentrations of genomic DNA were detected in 28 out of 100 Cobas 4800 extracts and were significantly more frequent in samples processed outside of the AIDS Reference Laboratory. An association between genomic DNA presence and spurious low-level viraemia results was demonstrated. Supplementary centrifugation of plasma before RNA extraction eliminated the contamination and the false viraemia. Plasma isolated from standard EDTA-containing blood collection tubes may contain traces of HIV DNA leading to false viral load results above the clinical cutoff. Supplementary centrifugation of plasma before viral load analysis may eliminate the occurrence of this spurious low-level viraemia.
Rangel, Uesliz Vianna; Gomes, Saint Clair dos Santos; Costa, Ana Maria Aranha Magalhães; Moreira, Maria Elisabeth Lopes
2014-01-01
OBJECTIVE: to relate the variables from a surveillance form for intravenous devices in high risk newborn infants with peripherally inserted central catheter related infection. METHODOLOGY: approximately 15 variables were studied, being associated with peripherally inserted central catheter related infection, this being defined by blood culture results. The variables analyzed were obtained from the surveillance forms used with intravenous devices, attached to the medical records of newborn infants weighing between 500 and 1,499 g. The statistical association was defined using the Chi-squared and Student t tests. The study was approved by the Research Ethics Committee of the Instituto Fernandes Figueira under process N. 140.703/12. RESULTS: 63 medical records were analyzed. The infection rate observed was 25.4%. Of the variables analyzed, only three had a statistically-significant relationship with the blood culture - the use of drugs capable of inhibiting acid secretion, post-natal steroid use, and undertaking more than one invasive procedure (p-value of 0.0141, 0.0472 and 0.0277, respectively). CONCLUSION: the absence of significance of the variables of the form may be related to the quality of the records and to the absence of standardization. It is recommended that the teams be encouraged to adhere to the protocol and fill out the form. PMID:25493681
Mechanical stimulation in the engineering of heart muscle.
Liaw, Norman Yu; Zimmermann, Wolfram-Hubertus
2016-01-15
Recreating the beating heart in the laboratory continues to be a formidable bioengineering challenge. The fundamental feature of the heart is its pumping action, requiring considerable mechanical forces to compress a blood filled chamber with a defined in- and outlet. Ventricular output crucially depends on venous loading of the ventricles (preload) and on the force generated by the preloaded ventricles to overcome arterial blood pressure (afterload). The rate of contraction is controlled by the spontaneously active sinus node and transmission of its electrical impulses into the ventricles. The underlying principles for these physiological processes are described by the Frank-Starling mechanism and Bowditch phenomenon. It is essential to consider these principles in the design and evaluation of tissue engineered myocardium. This review focuses on current strategies to evoke mechanical loading in hydrogel-based heart muscle engineering. Copyright © 2015. Published by Elsevier B.V.
Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.
Collins, Julie-Ann; Rudenski, Aram; Gibson, John; Howard, Luke; O'Driscoll, Ronan
2015-09-01
The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (S O2 ) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin-oxygen dissociation curve, a graphical representation of the relationship between oxygen satur-ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the S O2 in blood from patients with normal pH and S O2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (S pO2 ) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (S aO2 ) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable S pO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.
Vallejo, Abbe N.; Miller, Norman W.
1991-01-01
This work was undertaken to investigate whether or not antigen processing and presentation are important in channel catfish in vitro secondary immune responses elicited with structurally defined proteins, namely, pigeon heart cytochrome C (pCytC), hen egg lysozyme, and horse myoglobin. The use of in vitro antigen-pulsed and fixed B cells or monocytes as antigen presenting cells (APC) resulted in autologous peripheral blood leukocytes (PBL) responding with vigorous proliferation and antibody production in vitro. In addition, several long-term catfish monocyte lines have been found to function as efficient APC with autologous but not allogeneic responders. Subsequent separation of the responding PBL into sIg- (T-cell-enriched) and B (sIg+) cell subsets showed that both underwent proliferative responses to antigen-pulsed and fixed APC. Moreover, allogeneic cells used as APC were found to induce only strong mixed leukocyte reactions without specific in vitro antibody production. Initial attempts at identifying the immunogenic region(s) of the protein antigens for catfish indicated there are two such regions for pCytC, namely, peptides 66-80 and 81-104. PMID:1668258
Customized Molecular Phenotyping by Quantitative Gene Expression and Pattern Recognition Analysis
Akilesh, Shreeram; Shaffer, Daniel J.; Roopenian, Derry
2003-01-01
Description of the molecular phenotypes of pathobiological processes in vivo is a pressing need in genomic biology. We have implemented a high-throughput real-time PCR strategy to establish quantitative expression profiles of a customized set of target genes. It enables rapid, reproducible data acquisition from limited quantities of RNA, permitting serial sampling of mouse blood during disease progression. We developed an easy to use statistical algorithm—Global Pattern Recognition—to readily identify genes whose expression has changed significantly from healthy baseline profiles. This approach provides unique molecular signatures for rheumatoid arthritis, systemic lupus erythematosus, and graft versus host disease, and can also be applied to defining the molecular phenotype of a variety of other normal and pathological processes. PMID:12840047
Automated renal histopathology: digital extraction and quantification of renal pathology
NASA Astrophysics Data System (ADS)
Sarder, Pinaki; Ginley, Brandon; Tomaszewski, John E.
2016-03-01
The branch of pathology concerned with excess blood serum proteins being excreted in the urine pays particular attention to the glomerulus, a small intertwined bunch of capillaries located at the beginning of the nephron. Normal glomeruli allow moderate amount of blood proteins to be filtered; proteinuric glomeruli allow large amount of blood proteins to be filtered. Diagnosis of proteinuric diseases requires time intensive manual examination of the structural compartments of the glomerulus from renal biopsies. Pathological examination includes cellularity of individual compartments, Bowman's and luminal space segmentation, cellular morphology, glomerular volume, capillary morphology, and more. Long examination times may lead to increased diagnosis time and/or lead to reduced precision of the diagnostic process. Automatic quantification holds strong potential to reduce renal diagnostic time. We have developed a computational pipeline capable of automatically segmenting relevant features from renal biopsies. Our method first segments glomerular compartments from renal biopsies by isolating regions with high nuclear density. Gabor texture segmentation is used to accurately define glomerular boundaries. Bowman's and luminal spaces are segmented using morphological operators. Nuclei structures are segmented using color deconvolution, morphological processing, and bottleneck detection. Average computation time of feature extraction for a typical biopsy, comprising of ~12 glomeruli, is ˜69 s using an Intel(R) Core(TM) i7-4790 CPU, and is ~65X faster than manual processing. Using images from rat renal tissue samples, automatic glomerular structural feature estimation was reproducibly demonstrated for 15 biopsy images, which contained 148 individual glomeruli images. The proposed method holds immense potential to enhance information available while making clinical diagnoses.
Chrysohoou, Christina; Panagiotakos, Demosthenes B; Pitsavos, Christos; Skoumas, John; Economou, Manolis; Papadimitriou, Lambros; Stefanadis, Christodoulos
2007-05-01
We sought to evaluate the association between pre-hypertension status and oxidative stress markers (total antioxidant capacity (TAC) and oxidized low density lipoprotein (LDL)), in a random sample of cardiovascular disease-free adults. The ATTICA study is a cross-sectional population-based survey that conducted in Attica region during 2001-2002. Based on a multistage and stratified random sampling, 1514 men and 1528 women (18-89 years old) were enrolled. The survey included a detailed interview; blood samples collected after 12h of fasting and, among other clinical measurements, status of blood pressure levels was evaluated. Six hundred and fifty-three men (43%) and 535 women (35%) were defined as pre-hypertensives. Both systolic and diastolic blood pressures were inversely correlated with TAC (p<0.001) and positively correlated to oxidized LDL (p<0.001). Particularly, compared to normotensive subjects, pre-hypertensives had 7% lower TAC levels (p<0.001) and 15% higher oxidized LDL levels (p<0.05), after correcting for multiple comparisons and adjusting for age, body mass index, blood lipids, glucose, food groups consumed and other potential confounders. Studying a large sample of cardiovascular disease-free adults, we revealed an association of pre-hypertension with oxidative stress markers linking to atherosclerotic process.
Chacon, Diego; Beck, Dominik; Perera, Dilmi; Wong, Jason W H; Pimanda, John E
2014-01-01
The BloodChIP database (http://www.med.unsw.edu.au/CRCWeb.nsf/page/BloodChIP) supports exploration and visualization of combinatorial transcription factor (TF) binding at a particular locus in human CD34-positive and other normal and leukaemic cells or retrieval of target gene sets for user-defined combinations of TFs across one or more cell types. Increasing numbers of genome-wide TF binding profiles are being added to public repositories, and this trend is likely to continue. For the power of these data sets to be fully harnessed by experimental scientists, there is a need for these data to be placed in context and easily accessible for downstream applications. To this end, we have built a user-friendly database that has at its core the genome-wide binding profiles of seven key haematopoietic TFs in human stem/progenitor cells. These binding profiles are compared with binding profiles in normal differentiated and leukaemic cells. We have integrated these TF binding profiles with chromatin marks and expression data in normal and leukaemic cell fractions. All queries can be exported into external sites to construct TF-gene and protein-protein networks and to evaluate the association of genes with cellular processes and tissue expression.
Vernetti, Lawrence; Gough, Albert; Baetz, Nicholas; Blutt, Sarah; Broughman, James R.; Brown, Jacquelyn A.; Foulke-Abel, Jennifer; Hasan, Nesrin; In, Julie; Kelly, Edward; Kovbasnjuk, Olga; Repper, Jonathan; Senutovitch, Nina; Stabb, Janet; Yeung, Catherine; Zachos, Nick C.; Donowitz, Mark; Estes, Mary; Himmelfarb, Jonathan; Truskey, George; Wikswo, John P.; Taylor, D. Lansing
2017-01-01
Organ interactions resulting from drug, metabolite or xenobiotic transport between organs are key components of human metabolism that impact therapeutic action and toxic side effects. Preclinical animal testing often fails to predict adverse outcomes arising from sequential, multi-organ metabolism of drugs and xenobiotics. Human microphysiological systems (MPS) can model these interactions and are predicted to dramatically improve the efficiency of the drug development process. In this study, five human MPS models were evaluated for functional coupling, defined as the determination of organ interactions via an in vivo-like sequential, organ-to-organ transfer of media. MPS models representing the major absorption, metabolism and clearance organs (the jejunum, liver and kidney) were evaluated, along with skeletal muscle and neurovascular models. Three compounds were evaluated for organ-specific processing: terfenadine for pharmacokinetics (PK) and toxicity; trimethylamine (TMA) as a potentially toxic microbiome metabolite; and vitamin D3. We show that the organ-specific processing of these compounds was consistent with clinical data, and discovered that trimethylamine-N-oxide (TMAO) crosses the blood-brain barrier. These studies demonstrate the potential of human MPS for multi-organ toxicity and absorption, distribution, metabolism and excretion (ADME), provide guidance for physically coupling MPS, and offer an approach to coupling MPS with distinct media and perfusion requirements. PMID:28176881
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... for Red Blood Cells shall be the original blood containers unless the method of processing requires a...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... for Red Blood Cells shall be the original blood containers unless the method of processing requires a...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... for Red Blood Cells shall be the original blood containers unless the method of processing requires a...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... for Red Blood Cells shall be the original blood containers unless the method of processing requires a...
Definition of Drosophila hemocyte subsets by cell-type specific antigens.
Kurucz, Eva; Váczi, B; Márkus, R; Laurinyecz, Barbara; Vilmos, P; Zsámboki, J; Csorba, Kinga; Gateff, Elisabeth; Hultmark, D; Andó, I
2007-01-01
We analyzed the heterogeneity of Drosophila hemocytes on the basis of the expression of cell-type specific antigens. The antigens characterize distinct subsets which partially overlap with those defined by morphological criteria. On the basis of the expression or the lack of expression of blood cell antigens the following hemocyte populations have been defined: crystal cells, plasmatocytes, lamellocytes and precursor cells. The expression of the antigens and thus the different cell types are developmentally regulated. The hemocytes are arranged in four main compartments: the circulating blood cells, the sessile tissue, the lymph glands and the posterior hematopoietic tissue. Each hemocyte compartment has a specific and characteristic composition of the various cell types. The described markers represent the first successful attempt to define hemocyte lineages by immunological markers in Drosophila and help to define morphologically, functionally, spatially and developmentally distinct subsets of hemocytes.
Reduction of blood serum cholesterol
NASA Technical Reports Server (NTRS)
Winitz, M. (Inventor)
1974-01-01
By feeding a human subject as the sole source of sustenance a defined diet wherein the carbohydrate consists substantially entirely of glucose, maltose or a polysaccharide of glucose, the blood serum cholesterol level of the human subject is substantially reduced. If 25 percent of the carbohydrate is subsequently supplied in the form of sucrose, an immediate increase from the reduced level is observed. The remainder of the defined diet normally includes a source of amino acids, such as protein or a protein hydrolysate, vitamins, minerals and a source of essential fatty acid.
Data-driven asthma endotypes defined from blood biomarker and gene expression data
The diagnosis and treatment of childhood asthma is complicated by its mechanistically distinct subtypes (endotypes) driven by genetic susceptibility and modulating environmental factors. Clinical biomarkers and blood gene expression were collected from a stratified, cross-section...
Tomaszewski, Maciej; Debiec, Radoslaw; Braund, Peter S; Nelson, Christopher P; Hardwick, Robert; Christofidou, Paraskevi; Denniff, Matthew; Codd, Veryan; Rafelt, Suzanne; van der Harst, Pim; Waterworth, Dawn; Song, Kijoung; Vollenweider, Peter; Waeber, Gerard; Zukowska-Szczechowska, Ewa; Burton, Paul R; Mooser, Vincent; Charchar, Fadi J; Thompson, John R; Tobin, Martin D; Samani, Nilesh J
2010-01-01
Genetic determinants of blood pressure are poorly defined. We undertook a large-scale gene-centric analysis to identify loci and pathways associated with ambulatory systolic and diastolic blood pressure. We measured 24-hour ambulatory BP in 2020 individuals from 520 white European nuclear families (the GRAPHIC Study) and genotyped their DNA using the Illumina HumanCVD BeadChip array which contains approximately 50000 single nucleotide polymorphisms in >2000 cardiovascular candidate loci. We found a strong association between rs13306560 polymorphism in the promoter region of MTHFR and CLCN6 and mean 24-hour diastolic blood pressure - each minor allele copy of rs13306560 was associated with 2.6 mmHg lower mean 24-hour diastolic blood pressure (P=1.2×10−8). rs13306560 was also associated with clinic diastolic blood pressure in a combined analysis of 8129 subjects from the GRAPHIC Study, the CoLaus Study and the Silesian Cardiovascular Study (P=5.4×10−6). Additional analysis of associations between variants in Gene Ontology-defined pathways and mean 24-hour blood pressure in the GRAPHIC Study showed that cell survival control signalling cascades could play a role in blood pressure regulation. There was also a significant over-representation of rare variants (minor allele frequency <0.05) amongst polymorphisms showing at least nominal association with mean 24-hour blood pressure indicating that a considerable proportion of its heritability may be explained by uncommon alleles. Through a large scale gene-centric analysis of ambulatory blood pressure, we identified an association of a novel variant at the MTHFR/CLNC6 locus with diastolic blood pressure and provided new insights into the genetic architecture of blood pressure. PMID:21060006
[Innovative technology and blood safety].
Begue, S; Morel, P; Djoudi, R
2016-11-01
If technological innovations are not enough alone to improve blood safety, their contributions for several decades in blood transfusion are major. The improvement of blood donation (new apheresis devices, RFID) or blood components (additive solutions, pathogen reduction technology, automated processing of platelets concentrates) or manufacturing process of these products (by automated processing of whole blood), all these steps where technological innovations were implemented, lead us to better traceability, more efficient processes, quality improvement of blood products and therefore increased blood safety for blood donors and patients. If we are on the threshold of a great change with the progress of pathogen reduction technology (for whole blood and red blood cells), we hope to see production of ex vivo red blood cells or platelets who are real and who open new conceptual paths on blood safety. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.
Impact of hyperthermal rotary blood pump surfaces on blood clotting behavior: an approach.
Hamilton, Kathrin F; Schlanstein, Peter C; Mager, Ilona; Schmitz-Rode, Thomas; Steinseifer, Ulrich
2009-09-01
The influence of heat dissipating systems, such as rotary blood pumps, was investigated. Titanium cylinders as rotary blood pump housing dummies were immersed in porcine blood and constantly tempered at specific temperatures (37-60 degrees C) over a defined period of time. The porcine blood was anticoagulated either by low heparin dosage or citrate. At frequent intervals, samples were taken for blood analysis and the determination of the plasmatic coagulation cascade. Blood parameters do not alter at surface temperatures below 50 degrees C. Hyperthermia-induced hemolysis could be confirmed. The plasmatic coagulation cascade is terminated at surface temperatures exceeding 55 degrees C. The adhesion of blood constituents on surfaces is temperature and time dependent, and structural changes of adhesions and blood itself were detected.
Kimura, Shun-Ichi; Gomyo, Ayumi; Hayakawa, Jin; Tamaki, Masaharu; Akahoshi, Yu; Harada, Naonori; Ugai, Tomotaka; Kusuda, Machiko; Kameda, Kazuaki; Wada, Hidenori; Ishihara, Yuko; Kawamura, Koji; Sakamoto, Kana; Sato, Miki; Terasako-Saito, Kiriko; Kikuchi, Misato; Nakasone, Hideki; Kako, Shinichi; Tanihara, Aki; Kanda, Yoshinobu
2017-10-01
We evaluated the clinical significance of repeat blood cultures in persistent and recurrent fever during neutropenia in adult acute myeloid leukaemia (AML) and myelodysplastic syndrome (MDS) patients undergoing intensive chemotherapy. We retrospectively reviewed the chemotherapy cycles at our centre between January 2007 and December 2015. Blood cultures obtained within three days after initial febrile neutropenia (FN) were defined as initial blood cultures and those obtained on or after day 4 were defined as repeat blood cultures. Overall, 321 chemotherapy cycles in 89 patients were subjected to review. FN was identified in 276 (86.0%) chemotherapy cycles. In persistent FN (134 episodes), the causative pathogens were detected by repeat blood cultures in seven episodes (5.2%), including only three episodes (2.2%) of new infection. Shaking chills and high body temperature were identified as significant predictors for bloodstream infection (BSI). In recurrent FN (85 episodes), the causative pathogens were detected in seven episodes (8.2%), and all of these were new organisms. The frequency of detecting new pathogens by repeat blood cultures in recurrent FN (7/85) was higher than that in persistent FN (3/134) (p = .0491). A history of recent BSI was identified as a significant predictor for BSI in recurrent FN. The diagnostic yield of repeat blood cultures for persistent FN was low in intensive chemotherapy for AML and MDS. The frequency of repeat blood cultures for persistent FN could be reduced based on predictors. On the other hand, blood cultures were considered to be essential in cases with recurrent FN.
Hemorheological alterations in adults with prediabetes identified by hemoglobin A1c levels.
Marini, M A; Fiorentino, T V; Andreozzi, F; Mannino, G C; Succurro, E; Sciacqua, A; Perticone, F; Sesti, G
2017-07-01
A link between increased blood viscosity and type 2 diabetes has been previously reported. Herein, we investigated the association of blood viscosity with prediabetes, identified by glycated hemoglobin A1c (HbA1c) according to the new American Diabetes Association criteria, and subclinical atherosclerosis. The study cohort includes 1136 non-diabetic adults submitted to anthropometrical evaluation, an oral glucose tolerance test and ultrasound measurement of carotid intima-media thickness (IMT). Whole blood viscosity was estimated using a validated formula based on hematocrit and total plasma proteins. After adjusting for age, and gender, individuals with HbA1c-defined prediabetes (HbA1c 5.7-6.4% [39-47 mmol/mol]) exhibited significantly higher values of hematocrit, and predicted blood viscosity as compared with controls. Increased levels of IMT were observed in subjects with HbA1c-defined prediabetes in comparison to controls. Predicted blood viscosity was positively correlated with age, waist circumference, blood pressure, cholesterol, triglycerides, fibrinogen, white blood cell, HbA1c, fasting and 2-h post-load glucose levels, fasting insulin, IMT and inversely correlated with HDL and Matsuda index of insulin sensitivity. Of the three glycemic parameters, i.e. HbA1c, fasting and 2-h post-load glucose, only HbA1c showed a significant correlation with predicted blood viscosity (β = 0.054, P = 0.04) in a multivariate regression analysis model including multiple atherosclerosis risk factors. The study shows that individuals with HbA1c-defined prediabetes have increased predicted blood viscosity and IMT. The HbA1c criterion may be helpful to capture individuals with an increased risk of diabetes and cardiovascular disease who may benefit from an intensive lifestyle intervention. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.
Neuropathology of White Matter Lesions, Blood-Brain Barrier Dysfunction, and Dementia.
Hainsworth, Atticus H; Minett, Thais; Andoh, Joycelyn; Forster, Gillian; Bhide, Ishaan; Barrick, Thomas R; Elderfield, Kay; Jeevahan, Jamuna; Markus, Hugh S; Bridges, Leslie R
2017-10-01
We tested whether blood-brain barrier dysfunction in subcortical white matter is associated with white matter abnormalities or risk of clinical dementia in older people (n=126; mean age 86.4, SD: 7.7 years) in the MRC CFAS (Medical Research Council Cognitive Function and Ageing Study). Using digital pathology, we quantified blood-brain barrier dysfunction (defined by immunohistochemical labeling for the plasma marker fibrinogen). This was assessed within subcortical white matter tissue samples harvested from postmortem T 2 magnetic resonance imaging (MRI)-detected white matter hyperintensities, from normal-appearing white matter (distant from coexistent MRI-defined hyperintensities), and from equivalent areas in MRI normal brains. Histopathologic lesions were defined using a marker for phagocytic microglia (CD68, clone PGM1). Extent of fibrinogen labeling was not significantly associated with white matter abnormalities defined either by MRI (odds ratio, 0.90; 95% confidence interval, 0.79-1.03; P =0.130) or by histopathology (odds ratio, 0.93; 95% confidence interval, 0.77-1.12; P =0.452). Among participants with normal MRI (no detectable white matter hyperintensities), increased fibrinogen was significantly related to decreased risk of clinical dementia (odds ratio, 0.74; 95% confidence interval, 0.58-0.94; P =0.013). Among participants with histological lesions, increased fibrinogen was related to increased risk of dementia (odds ratio, 2.26; 95% confidence interval, 1.25-4.08; P =0.007). Our data suggest that some degree of blood-brain barrier dysfunction is common in older people and that this may be related to clinical dementia risk, additional to standard MRI biomarkers. © 2017 American Heart Association, Inc.
The productivity limit of manufacturing blood cell therapy in scalable stirred bioreactors
Bayley, Rachel; Ahmed, Forhad; Glen, Katie; McCall, Mark; Stacey, Adrian
2017-01-01
Abstract Manufacture of red blood cells (RBCs) from progenitors has been proposed as a method to reduce reliance on donors. Such a process would need to be extremely efficient for economic viability given a relatively low value product and high (2 × 1012) cell dose. Therefore, the aim of these studies was to define the productivity of an industry standard stirred‐tank bioreactor and determine engineering limitations of commercial red blood cells production. Cord blood derived CD34+ cells were cultured under erythroid differentiation conditions in a stirred micro‐bioreactor (Ambr™). Enucleated cells of 80% purity could be created under optimal physical conditions: pH 7.5, 50% oxygen, without gas‐sparging (which damaged cells) and with mechanical agitation (which directly increased enucleation). O2 consumption was low (~5 × 10–8 μg/cell.h) theoretically enabling erythroblast densities in excess of 5 × 108/ml in commercial bioreactors and sub‐10 l/unit production volumes. The bioreactor process achieved a 24% and 42% reduction in media volume and culture time, respectively, relative to unoptimized flask processing. However, media exchange limited productivity to 1 unit of erythroblasts per 500 l of media. Systematic replacement of media constituents, as well as screening for inhibitory levels of ammonia, lactate and key cytokines did not identify a reason for this limitation. We conclude that the properties of erythroblasts are such that the conventional constraints on cell manufacturing efficiency, such as mass transfer and metabolic demand, should not prevent high intensity production; furthermore, this could be achieved in industry standard equipment. However, identification and removal of an inhibitory mediator is required to enable these economies to be realized. Copyright © 2016 The Authors Journal of Tissue Engineering and Regenerative Medicine Published by John Wiley & Sons Ltd. PMID:27696710
Yoon, Chiyul; Noh, Seungwoo; Lee, Jung Chan; Ko, Sung Ho; Ahn, Wonsik; Kim, Hee Chan
2014-03-01
The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.
Providing best practice in manual blood pressure measurement.
Alexis, Obrey
This article discusses the practical skills and underpinning knowledge needed when manually taking a patients blood pressure. The author defines blood pressure and the terms systolic and diastolic and explores the purpose of manual measurement. The article also goes on to examine what is meant by normal blood pressure, hypertension and hypotension, as well as factors that may influence blood pressure measurement. There is a brief outline of the equipment used for manually measuring blood pressure, followed by some factors that may affect the accuracy of the final reading. The author also highlights the different positions used for taking blood pressure and the arguments surrounding their respective merits. Finally, the article includes a practical step-by-step guide to manual blood pressure measurement.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.
Crowley, Candace M; Fontaine, Justin H; Gerriets, Joan E; Schelegle, Edward S; Hyde, Dallas M; Miller, Lisa A
2017-08-01
Early life is a critical period for the progressive establishment of immunity in response to environmental stimuli; the impact of airborne challenges on this process is not well defined. In a longitudinal fashion, we determined the effect of episodic house dust mite (HDM) aerosol and ozone inhalation, both separately and combined, on peripheral blood immune cell phenotypes and cytokine expression from 4 to 25weeks of age in an infant rhesus monkey model of childhood development. Immune profiles in peripheral blood were compared with lung lavage at 25weeks of age. Independent of exposure, peripheral blood cell counts fluctuated with chronologic age of animals, while IFNγ and IL-4 mRNA levels increased over time in a linear fashion. At 12weeks of age, total WBC, lymphocyte numbers, FoxP3 mRNA and IL-12 mRNA were dramatically reduced relative to earlier time points, but increased to a steady state with age. Exposure effects were observed for monocyte numbers, as well as CCR3, FoxP3, and IL-12 mRNA levels in peripheral blood. Significant differences in cell surface marker and cytokine expression were detected following in vitro HDM or PMA/ionomycin stimulation of PBMC isolated from animals exposed to either HDM or ozone. Lavage revealed a mixed immune phenotype of FoxP3, IFNγ and eosinophilia in association with combined HDM plus ozone exposure, which was not observed in blood. Collectively, our findings show that airborne challenges during postnatal development elicit measureable cell and cytokine changes in peripheral blood over time, but exposure-induced immune profiles are not mirrored in the lung. Copyright © 2017 Elsevier Inc. All rights reserved.
Qu, Zhiguo; Guo, Shengnan; Fang, Guojun; Cui, Zhenghong; Liu, Ying
2015-04-01
We have previously grafted human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) with blood plasma to treat rat tibia nonunion. To further examine the biological characteristics of this process, we applied an established hUC-MSCs-treated rat nonunion model with the addition of an inhibitor of AKT. SD rats (80) were randomly divided into four groups: a fracture group (positive control); a nonunion group (negative control); a hUC-MSCs grafting with blood plasma group; and a hUC-MSCs grafting with blood plasma & AKT blocker group. The animals were sacrificed under deep anesthesia at 4 and 8 weeks post fracture for analysis. The fracture line became less defined at 4 weeks and disappeared at 8 weeks postoperatively in both the hUC-MSCs grafting with blood plasma and grafting with blood plasma & the AKT blocker, which is similar to the fracture group. Histological immunofluorescence studies showed that the numbers of hUC-MSCs in the calluses were significantly higher in the hUC-MSCs grafting with blood plasma than those in group with the AKT blocker. More bone morphogenetic protein 2 and bone sialoprotein expression and less osteoprotegerin and bone gla protein expression were observed in the AKT blocker group compared to the hUC-MSCs grafting with blood plasma. AKT gene expression in the AKT blocker group was decreased 50% compared to the hUC-MSCs with plasma group and decreased 70% compared to the fracture group, while the elastic modulus was decreased. In summary, our work demonstrates that AKT may play a role in modulating osteogenesis induced by hUC-MSCs.
Optical tweezers for measuring the interaction of the two single red blood cells in flow condition
NASA Astrophysics Data System (ADS)
Lee, Kisung; Muravyov, Alexei; Semenov, Alexei; Wagner, Christian; Priezzhev, Alexander
2017-03-01
Aggregation of red blood cells (RBCs) is an intrinsic property of blood, which has direct effect on the blood viscosity and therefore affects overall the blood circulation throughout the body. It is attracting interest for the research in both fundamental science and clinical application. Despite of the intensive research, the aggregation mechanism is remaining not fully clear. Recent advances in methods allowed measuring the interaction between single RBCs in a well-defined configuration leading the better understanding of the mechanism of the process. However the most of the studies were made on the static cells. Thus, the measurements in flow mimicking conditions are missing. In this work, we aim to study the interaction of two RBCs in the flow conditions. We demonstrate the characterization of the cells interaction strength (or flow tolerance) by measuring the flow velocity to be applied to separate two aggregated cells trapped by double channel optical tweezers in a desired configuration. The age-separated cells were used for this study. The obtained values for the minimum flow velocities needed to separate the two cells were found to be 78.9 +/- 6.1 μm/s and 110 +/- 13 μm/s for old and young cells respectively. The data obtained is in agreement with the observations reported by other authors. The significance of our results is in ability for obtaining a comprehensible and absolute physical value characterizing the cells interaction in flow conditions (not like the Aggregation Index measured in whole blood suspensions by other techniques, which is some abstract parameter)
Blood Pump Having a Magnetically Suspended Rotor
NASA Technical Reports Server (NTRS)
Antaki, James F. (Inventor); Paden, Bradley (Inventor); Burgreen, Gregory (Inventor); Groom, Nelson J. (Inventor)
2002-01-01
A blood pump preferably has a magnetically suspended rotor that rotates within a housing. The rotor may rotate about a stator disposed within the housing. Radial magnetic bearings may be defined within the stator and the rotor in order to suspend the rotor. The radial magnetic bearings may be passive magnetic bearings that include permanent magnets disposed within the stator and the rotor or active magnetic bearings. The pump may further include an axial magnetic bearing that may be either a passive or an active magnetic bearing. A motor that drives the rotor may be disposed within the housing in order to more easily dissipate heat generated by the motor. A primary flow path is defined between the rotor and the stator, and a secondary flow path is defined between the stator and the rotor. Preferably, a substantial majority of blood passes through the primary flow path. The secondary flow path is large enough so that it provides adequate flushing of the secondary flow path while being small enough to permit efficient operation of the radial magnet bearings across the secondary flow path.
Blood Pump Having a Magnetically Suspended Rotor
NASA Technical Reports Server (NTRS)
Antaki, James F. (Inventor); Paden, Bradley (Inventor); Burgreen, Gregory (Inventor); Groom, Nelson J. (Inventor)
2001-01-01
A blood pump preferably has a magnetically suspended rotor that rotates within a housing. The rotor may rotate about a stator disposed within the housing. Radial magnetic bearings may be defined within the stator and the rotor in order to suspend the rotor. The radial magnetic bearings may be passive magnetic bearings that include permanent magnets disposed within the stator and the rotor or active magnetic bearings. The pump may further include an axial magnetic bearing that may be either a passive or an active magnetic bearing. A motor that drives the rotor may be disposed within the housing in order to more easily dissipate heat generated by the motor. A primary flow path is defined between the rotor and the stator, and a secondary flow path is defined between the stator and the rotor. Preferably, a substantial majority of blood passes through the primary flow path. The secondary flow path is large enough so that it provides adequate flushing of the secondary flow path while being small enough to permit efficient operation of the radial magnet bearings across the secondary flow path.
Gómez Rioja, Rubén; Martínez Espartosa, Débora; Segovia, Marta; Ibarz, Mercedes; Llopis, María Antonia; Bauça, Josep Miquel; Marzana, Itziar; Barba, Nuria; Ventura, Monserrat; García Del Pino, Isabel; Puente, Juan José; Caballero, Andrea; Gómez, Carolina; García Álvarez, Ana; Alsina, María Jesús; Álvarez, Virtudes
2018-05-05
The stability limit of an analyte in a biological sample can be defined as the time required until a measured property acquires a bias higher than a defined specification. Many studies assessing stability and presenting recommendations of stability limits are available, but differences among them are frequent. The aim of this study was to classify and to grade a set of bibliographic studies on the stability of five common blood measurands and subsequently generate a consensus stability function. First, a bibliographic search was made for stability studies for five analytes in blood: alanine aminotransferase (ALT), glucose, phosphorus, potassium and prostate specific antigen (PSA). The quality of every study was evaluated using an in-house grading tool. Second, the different conditions of stability were uniformly defined and the percent deviation (PD%) over time for each analyte and condition were scattered while unifying studies with similar conditions. From the 37 articles considered as valid, up to 130 experiments were evaluated and 629 PD% data were included (106 for ALT, 180 for glucose, 113 for phosphorus, 145 for potassium and 85 for PSA). Consensus stability equations were established for glucose, potassium, phosphorus and PSA, but not for ALT. Time is the main variable affecting stability in medical laboratory samples. Bibliographic studies differ in recommedations of stability limits mainly because of different specifications for maximum allowable error. Definition of a consensus stability function in specific conditions can help laboratories define stability limits using their own quality specifications.
[Correlations between functional activity of animal blood lymphocytes and change in solar activity].
Karnaukhova, N A; Sergievich, L A
1999-01-01
It is shown that increase of Solar activity as measurement of the intensity of solar radio emissions at frequency of 2804 MHz leads to the reducing of the functional activity of immunocompetent cells in animal blood defining by parameter alpha.
Peeters, Bart; Geerts, Inge; Van Mullem, Mia; Micalessi, Isabel; Saegeman, Veroniek; Moerman, Jan
2016-05-01
Many hospitals opt for early postnatal discharge of newborns with a potential risk of readmission for neonatal hyperbilirubinemia. Assays/algorithms with the possibility to improve prediction of significant neonatal hyperbilirubinemia are needed to optimize screening protocols and safe discharge of neonates. This study investigated the predictive value of umbilical cord blood (UCB) testing for significant hyperbilirubinemia. Neonatal UCB bilirubin, UCB direct antiglobulin test (DAT), and blood group were determined, as well as the maternal blood group and the red blood cell antibody status. Moreover, in newborns with clinically apparent jaundice after visual assessment, plasma total bilirubin (TB) was measured. Clinical factors positively associated with UCB bilirubin were ABO incompatibility, positive DAT, presence of maternal red cell antibodies, alarming visual assessment and significant hyperbilirubinemia in the first 6 days of life. UCB bilirubin performed clinically well with an area under the receiver-operating characteristic curve (AUC) of 0.82 (95 % CI 0.80-0.84). The combined UCB bilirubin, DAT, and blood group analysis outperformed results of these parameters considered separately to detect significant hyperbilirubinemia and correlated exponentially with hyperbilirubinemia post-test probability. Post-test probabilities for neonatal hyperbilirubinemia can be calculated using exponential functions defined by UCB bilirubin, DAT, and ABO compatibility results. • The diagnostic value of the triad umbilical cord blood bilirubin measurement, direct antiglobulin testing and blood group analysis for neonatal hyperbilirubinemia remains unclear in literature. • Currently no guideline recommends screening for hyperbilirubinemia using umbilical cord blood. What is New: • Post-test probability for hyperbilirubinemia correlated exponentially with umbilical cord blood bilirubin in different risk groups defined by direct antiglobulin test and ABO blood group compatibility results. • Exponential functions can be used to calculate hyperbilirubinemia probability.
A close look at brain dynamics: cells and vessels seen by in vivo two-photon microscopy.
Fumagalli, Stefano; Ortolano, Fabrizio; De Simoni, Maria-Grazia
2014-10-01
The cerebral vasculature has a unique role in providing a constant supply of oxygen and nutrients to ensure normal brain functions. Blood vessels that feed the brain are far from being simply channels for passive transportation of fluids. They form complex structures made up of different cell types. These structures regulate blood supply, local concentrations of O2 and CO2, transport of small molecules, trafficking of plasma cells and fine cerebral functions in normal and diseased brains. Until few years ago, analysis of these functions has been typically based on post mortem techniques, whose interpretation is limited by the need for tissue processing at specific times. For a reliable and effective picture of the dynamic processes in the central nervous system, real-time information in vivo is required. There are now few in vivo systems, among which two-photon microscopy (2-PM) is a truly innovative tool for studying the brain. 2-PM has been used to dissect specific aspects of vascular and immune cell dynamics in the context of neurological diseases, providing exciting results that could not have been obtained with conventional methods. This review summarizes the latest findings on vascular and immune system action in the brain, with particular focus on the dynamic responses after ischemic brain injury. 2-PM has helped define the hierarchical architecture of the brain vasculature, the dynamic interaction between the vasculature and immune cells recruited to lesion sites, the effects of blood flow on neuronal and microglial activity and the ability of cells of the neurovascular unit to regulate blood flow. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ramírez, Carlos; Mendoza, Luis
2018-04-01
Blood cell formation has been recognized as a suitable system to study celular differentiation mainly because of its experimental accessibility, and because it shows characteristics such as hierarchical and gradual bifurcated patterns of commitment, which are present in several developmental processes. Although hematopoiesis has been extensively studied and there is a wealth of molecular and cellular data about it, it is not clear how the underlying molecular regulatory networks define or restrict cellular differentiation processes. Here, we infer the molecular regulatory network that controls the differentiation of a blood cell subpopulation derived from the granulocyte-monocyte precursor (GMP), comprising monocytes, neutrophils, eosinophils, basophils and mast cells. We integrate published qualitative experimental data into a model to describe temporal expression patterns observed in GMP-derived cells. The model is implemented as a Boolean network, and its dynamical behavior is studied. Steady states of the network can be clearly identified with the expression profiles of monocytes, mast cells, neutrophils, basophils, and eosinophils, under wild-type and mutant backgrounds. All scripts are publicly available at https://github.com/caramirezal/RegulatoryNetworkGMPModel. lmendoza@biomedicas.unam.mx. Supplementary data are available at Bioinformatics online.
Lehmann, Marcus; Schoeman, Rogier M; Krohl, Patrick J; Wallbank, Alison M; Samaniuk, Joseph R; Jandrot-Perrus, Martine; Neeves, Keith B
2018-05-01
The objective of this study was to measure the role of platelets and red blood cells on thrombus propagation in an in vitro model of venous valvular stasis. A microfluidic model with dimensional similarity to human venous valves consists of a sinus distal to a sudden expansion, where for sufficiently high Reynolds numbers, 2 countercurrent vortices arise because of flow separation. The primary vortex is defined by the points of flow separation and reattachment. A secondary vortex forms in the deepest recess of the valve pocket characterized by low shear rates. An initial fibrin gel formed within the secondary vortex of a tissue factor-coated valve sinus. Platelets accumulated at the interface of the fibrin gel and the primary vortex. Red blood cells at physiological hematocrits were necessary to provide an adequate flux of platelets to support thrombus growth out of the valve sinus. A subpopulation of platelets that adhered to fibrin expose phosphatidylserine. Platelet-dependent thrombus growth was attenuated by inhibition of glycoprotein VI with a blocking Fab fragment or D-dimer. A 3-step process regulated by hemodynamics was necessary for robust thrombus propagation: First, immobilized tissue factor initiates coagulation and fibrin deposition within a low flow niche defined by a secondary vortex in the pocket of a model venous valve. Second, a primary vortex delivers platelets to the fibrin interface in a red blood cell-dependent manner. Third, platelets adhere to fibrin, activate through glycoprotein VI, express phosphatidylserine, and subsequently promote thrombus growth beyond the valve sinus and into the bulk flow. © 2018 American Heart Association, Inc.
Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum
2007-06-01
To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible method of tumor perfusion surveillance than comparison of single representative tumor sections. (c) RSNA, 2007.
Draenert, K; Draenert, M; Erler, M; Draenert, A; Draenert, Y
2011-09-01
The behaviour of physiological biomaterials, β-tricalciumphosphate and hydroxyapatite, is analysed based on current literature and our own experimental work. The properties of graft substitutes based on ceramic materials are clearly defined according to their scientific efficiency. The strength of the materials and their biodegradability are still not fully evaluated. Strength and degradability have a direct proportional relationship and are considered the most efficient way to be adapted by their properties to the needs for the treatment of bone defects. New technologies for the manufacturing process are presented that increase those properties and thus open up new indications and easier application of the ceramic materials. The implantation process as well is carefully validated by animal experiments to avoid failures. Based on the experiments, a completely new approach is defined as to how primary bone formation with osteoconductive ceramics can be achieved. The milestones in that approach comprise a synthetically manufactured replica of the bone marrow spaces as osteoconductive ladder, whereas the bead is defined as bone-forming element. As a result, materials are available with high strength if the ceramic is solid or highly porous and possesses a micro-structure. The injection moulding process allows for the combination of high strength of the material with high porosity. Based on the strong capillary forces, micro-chambered beads fulfil most expectations for primary bone formation in cancellous bone defects, including drug delivery, mechanical strengthening if necessary, and stable implantation in situ by coagulation of the blood and bone marrow suctioned in. Copyright © 2011 Elsevier Ltd. All rights reserved.
In microfluidico: Recreating in vivo hemodynamics using miniaturized devices
Zhu, Shu; Herbig, Bradley A.; Li, Ruizhi; Colace, Thomas V.; Muthard, Ryan W.; Neeves, Keith B.; Diamond, Scott L.
2016-01-01
Microfluidic devices create precisely controlled reactive blood flows and typically involve: (i) validated anticoagulation/pharmacology protocols, (ii) defined reactive surfaces, (iii) defined flow-transport regimes, and (iv) optical imaging. An 8-channel device can be run at constant flow rate or constant pressure drop for blood perfusion over a patterned collagen, collagen/kaolin, or collagen/tissue factor (TF) to measure platelet, thrombin, and fibrin dynamics during clot growth. A membrane-flow device delivers a constant flux of platelet agonists or coagulation enzymes into flowing blood. A trifurcated device sheaths a central blood flow on both sides with buffer, an ideal approach for on-chip recalcification of citrated blood or drug delivery. A side-view device allows clotting on a porous collagen/TF plug at constant pressure differential across the developing clot. The core-shell architecture of clots made in mouse models can be replicated in this device using human blood. For pathological flows, a stenosis device achieves shear rates of >100,000 s−1 to drive plasma von Willebrand factor (VWF) to form thick long fibers on collagen. Similarly, a micropost-impingement device creates extreme elongational and shear flows for VWF fiber formation without collagen. Overall, microfluidics are ideal for studies of clotting, bleeding, fibrin polymerization/fibrinolysis, cell/clot mechanics, adhesion, mechanobiology, and reaction-transport dynamics. PMID:26600269
Nasal lavage, blood or sputum: Which is best for phenotyping asthma?
de Farias, Camyla F; Amorim, Maria M F; Dracoulakis, Michel; Caetano, Lilian B; Santoro, Ilka L; Fernandes, Ana L G
2017-05-01
Determination of asthma phenotypes, particularly inflammatory phenotypes, helps guide treatment and management of this heterogeneous disease. Induced sputum cytology has been the gold standard for determination of inflammatory phenotypes, but sputum induction is fairly invasive and technically challenging. Blood and nasal lavage cytology have been suggested as substitutes, but have not been fully verified. The aim of this study is to determine the accuracy of blood and nasal lavage cytometry as indicators of inflammatory phenotypes in asthma. Clinical evaluation, Asthma Control Questionnaire (ACQ) and spirometry were performed for 121 adult asthma patients, and blood, nasal lavage and induced sputum samples were taken. Eosinophils and neutrophils were counted in three samples from each subject. Inflammatory phenotypes (eosinophilic, neutrophilic, mixed and paucicellular) and cells counts were analysed using Venn diagram and receiver operating characteristic (ROC) curve, respectively. ACQ score, spirometry and bronchodilator response did not differ among subjects with different inflammatory phenotypes. Inflammatory phenotypes defined by nasal lavage cytometry were in better concordance than those defined by blood cell counts with phenotypes determined by sputum cytology, and were significantly correlated with sputum phenotypes. For eosinophilia, nasal lavage cytology showed better accuracy than blood cytology (area under the curve (AUC): 0.89 vs 0.65). For all phenotypes, sensitivity and positive and negative predictive power were higher for nasal lavage cytometry than for blood. Blood cell counts gave a high level of false positives for all inflammatory phenotypes. We recommend nasal lavage cytology over blood cell count as a substitute for sputum cytology to identify inflammatory phenotypes in asthma. © 2016 Asian Pacific Society of Respirology.
Hemodynamics model of fluid–solid interaction in internal carotid artery aneurysms
Fu-Yu, Wang; Lei, Liu; Xiao-Jun, Zhang; Hai-Yue, Ju
2010-01-01
The objective of this study is to present a relatively simple method to reconstruct cerebral aneurysms as 3D numerical grids. The method accurately duplicates the geometry to provide computer simulations of the blood flow. Initial images were obtained by using CT angiography and 3D digital subtraction angiography in DICOM format. The image was processed by using MIMICS software, and the 3D fluid model (blood flow) and 3D solid model (wall) were generated. The subsequent output was exported to the ANSYS workbench software to generate the volumetric mesh for further hemodynamic study. The fluid model was defined and simulated in CFX software while the solid model was calculated in ANSYS software. The force data calculated firstly in the CFX software were transferred to the ANSYS software, and after receiving the force data, total mesh displacement data were calculated in the ANSYS software. Then, the mesh displacement data were transferred back to the CFX software. The data exchange was processed in workbench software. The results of simulation could be visualized in CFX-post. Two examples of grid reconstruction and blood flow simulation for patients with internal carotid artery aneurysms were presented. The wall shear stress, wall total pressure, and von Mises stress could be visualized. This method seems to be relatively simple and suitable for direct use by neurosurgeons or neuroradiologists, and maybe a practical tool for planning treatment and follow-up of patients after neurosurgical or endovascular interventions with 3D angiography. PMID:20812022
Hemodynamics model of fluid-solid interaction in internal carotid artery aneurysms.
Bai-Nan, Xu; Fu-Yu, Wang; Lei, Liu; Xiao-Jun, Zhang; Hai-Yue, Ju
2011-01-01
The objective of this study is to present a relatively simple method to reconstruct cerebral aneurysms as 3D numerical grids. The method accurately duplicates the geometry to provide computer simulations of the blood flow. Initial images were obtained by using CT angiography and 3D digital subtraction angiography in DICOM format. The image was processed by using MIMICS software, and the 3D fluid model (blood flow) and 3D solid model (wall) were generated. The subsequent output was exported to the ANSYS workbench software to generate the volumetric mesh for further hemodynamic study. The fluid model was defined and simulated in CFX software while the solid model was calculated in ANSYS software. The force data calculated firstly in the CFX software were transferred to the ANSYS software, and after receiving the force data, total mesh displacement data were calculated in the ANSYS software. Then, the mesh displacement data were transferred back to the CFX software. The data exchange was processed in workbench software. The results of simulation could be visualized in CFX-post. Two examples of grid reconstruction and blood flow simulation for patients with internal carotid artery aneurysms were presented. The wall shear stress, wall total pressure, and von Mises stress could be visualized. This method seems to be relatively simple and suitable for direct use by neurosurgeons or neuroradiologists, and maybe a practical tool for planning treatment and follow-up of patients after neurosurgical or endovascular interventions with 3D angiography.
Radke, Teja Falk; Barbosa, David; Duggleby, Richard Charles; Saccardi, Riccardo; Querol, Sergio; Kögler, Gesine
2013-01-01
The assessment of nonviable haematopoietic cells by Annexin V staining method in flow cytometry has recently been published by Duggleby et al. Resulting in a better correlation with the observed colony formation in methylcellulose assays than the standard ISHAGE protocol, it presents a promising method to predict cord blood potency. Herein, we applied this method for examining the parameters during processing which potentially could affect cord blood viability. We could verify that the current standards regarding time and temperature are sufficient, since no significant difference was observed within 48 hours or in storage at 4°C up to 26°C. However, the addition of DMSO for cryopreservation alone leads to an inevitable increase in nonviable haematopoietic stem cells from initially 14.8% ± 4.3% to at least 30.6% ± 5.5%. Furthermore, CFU-assays with varied seeding density were performed in order to evaluate the applicability as a quantitative method. The results revealed that only in a narrow range reproducible clonogenic efficiency (ClonE) could be assessed, giving at least a semiquantitative estimation. We conclude that both Annexin V staining method and CFU-assays with defined seeding density are reliable means leading to a better prediction of the final potency. Especially Annexin V, due to its fast readout, is a practical tool for examining and optimising specific steps in processing, while CFU-assays add a functional confirmation. PMID:23533443
Lipid and liver abnormalities in haemoglobin A1c-defined prediabetes and type 2 diabetes.
Calanna, S; Scicali, R; Di Pino, A; Knop, F K; Piro, S; Rabuazzo, A M; Purrello, F
2014-06-01
We aimed to investigate lipid abnormalities and liver steatosis in patients with HbA1c-defined prediabetes and type 2 diabetes compared to individuals with HbA1c-defined normoglycaemia. Ninety-one subjects with prediabetes according to HbA1c, i.e. from 5.7 to 6.4% (39-46 mmol/mol), 50 newly diagnosed patients with HbA1c-defined type 2 diabetes (HbA1c ≥6.5% [≥48 mmol/mol]), and 67 controls with HbA1c lower than 5.7% (<39 mmol/mol), were studied. Fasting blood samples for lipid profiles, fatty liver index (FLI), bioimpedance analysis, ultrasound scan of the liver, and BARD (body mass index, aspartate aminotransferase/alanine aminotransferase ratio, diabetes) score for evaluation of liver fibrosis, were performed in all subjects. In comparison to controls, subjects with prediabetes were characterised by: lower apolipoprotein AI and HDL cholesterol levels, higher blood pressure, triglycerides levels and apolipoprotein B/apolipoprotein AI ratio, higher FLI, increased prevalence of and more severe hepatic steatosis, similar BARD score, and higher total body fat mass. In comparison to subjects with diabetes, subjects with prediabetes exhibited: similar blood pressure and apolipoprotein B/apolipoprotein AI ratio, similar FLI, reduced prevalence of and less severe hepatic steatosis, lower BARD score, increased percent fat and lower total body muscle mass. In comparison to controls, subjects with diabetes showed: lower apolipoprotein AI and HDL cholesterol levels, higher blood pressure and triglycerides levels, higher FLI, increased prevalence of and more severe hepatic steatosis, higher BARD score, and higher total body muscle mass. Moreover, HbA1c was correlated with BMI, HOMA-IR, triglycerides, HDL cholesterol, AST, and ALT. Subjects with HbA1c-defined prediabetes and type 2 diabetes, respectively, are characterised by abnormalities in lipid profile and liver steatosis, thus exhibiting a severe risk profile for cardiovascular and liver diseases. Copyright © 2014 Elsevier B.V. All rights reserved.
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
Liadov, V K; Skrypnikova, M A; Popova, O P
2014-01-01
There is evidence of the importance of circulating tumor cells in bloodstream as a factor of poor prognosis of cancer. The optimum method for isolating and studying of these cells is not defined. The most common methods are either based on the isolation of tumor genetic material from blood or on immune-mediated isolation of epithelial tumor cells. The first group of methods is characterized by a lack of specificity, while the latter do not allow identifying a pool of cells undergone in bloodstream epithelial-mesenchymal transformation. There is presented an overview of results of clinical trials of a new technique of isolation of tumor cells from bloodstream based on the patients' blood filtration through a membrane with defined pore sizes (ISET-Isolation by SizE of Tumor cells).
Kidney-inspired algorithm for optimization problems
NASA Astrophysics Data System (ADS)
Jaddi, Najmeh Sadat; Alvankarian, Jafar; Abdullah, Salwani
2017-01-01
In this paper, a population-based algorithm inspired by the kidney process in the human body is proposed. In this algorithm the solutions are filtered in a rate that is calculated based on the mean of objective functions of all solutions in the current population of each iteration. The filtered solutions as the better solutions are moved to filtered blood and the rest are transferred to waste representing the worse solutions. This is a simulation of the glomerular filtration process in the kidney. The waste solutions are reconsidered in the iterations if after applying a defined movement operator they satisfy the filtration rate, otherwise it is expelled from the waste solutions, simulating the reabsorption and excretion functions of the kidney. In addition, a solution assigned as better solution is secreted if it is not better than the worst solutions simulating the secreting process of blood in the kidney. After placement of all the solutions in the population, the best of them is ranked, the waste and filtered blood are merged to become a new population and the filtration rate is updated. Filtration provides the required exploitation while generating a new solution and reabsorption gives the necessary exploration for the algorithm. The algorithm is assessed by applying it on eight well-known benchmark test functions and compares the results with other algorithms in the literature. The performance of the proposed algorithm is better on seven out of eight test functions when it is compared with the most recent researches in literature. The proposed kidney-inspired algorithm is able to find the global optimum with less function evaluations on six out of eight test functions. A statistical analysis further confirms the ability of this algorithm to produce good-quality results.
Piatti, Filippo; Palumbo, Maria Chiara; Consolo, Filippo; Pluchinotta, Francesca; Greiser, Andreas; Sturla, Francesco; Votta, Emiliano; Siryk, Sergii V; Vismara, Riccardo; Fiore, Gianfranco Beniamino; Lombardi, Massimo; Redaelli, Alberto
2018-02-08
The performance of blood-processing devices largely depends on the associated fluid dynamics, which hence represents a key aspect in their design and optimization. To this aim, two approaches are currently adopted: computational fluid-dynamics, which yields highly resolved three-dimensional data but relies on simplifying assumptions, and in vitro experiments, which typically involve the direct video-acquisition of the flow field and provide 2D data only. We propose a novel method that exploits space- and time-resolved magnetic resonance imaging (4D-flow) to quantify the complex 3D flow field in blood-processing devices and to overcome these limitations. We tested our method on a real device that integrates an oxygenator and a heat exchanger. A dedicated mock loop was implemented, and novel 4D-flow sequences with sub-millimetric spatial resolution and region-dependent velocity encodings were defined. Automated in house software was developed to quantify the complex 3D flow field within the different regions of the device: region-dependent flow rates, pressure drops, paths of the working fluid and wall shear stresses were computed. Our analysis highlighted the effects of fine geometrical features of the device on the local fluid-dynamics, which would be unlikely observed by current in vitro approaches. Also, the effects of non-idealities on the flow field distribution were captured, thanks to the absence of the simplifying assumptions that typically characterize numerical models. To the best of our knowledge, our approach is the first of its kind and could be extended to the analysis of a broad range of clinically relevant devices. Copyright © 2017 Elsevier Ltd. All rights reserved.
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2012 CFR
2012-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2011 CFR
2011-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2014 CFR
2014-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
Massive blood transfusion during hospitalization for delivery in New York State, 1998-2007.
Mhyre, Jill M; Shilkrut, Alexander; Kuklina, Elena V; Callaghan, William M; Creanga, Andreea A; Kaminsky, Sari; Bateman, Brian T
2013-12-01
To define the frequency, risk factors, and outcomes of massive transfusion in obstetrics. The State Inpatient Dataset for New York (1998-2007) was used to identify all delivery hospitalizations for hospitals that reported at least one delivery-related transfusion per year. Multivariable logistic regression analysis was performed to examine the relationship between maternal age, race, and relevant clinical variables and the risk of massive blood transfusion defined as 10 or more units of blood recorded. Massive blood transfusion complicated 6 of every 10,000 deliveries with cases observed even in the smallest facilities. Risk factors with the strongest independent associations with massive blood transfusion included abnormal placentation (1.6/10,000 deliveries, adjusted odds ratio [OR] 18.5, 95% confidence interval [CI] 14.7-23.3), placental abruption (1.0/10,000, adjusted OR 14.6, 95% CI 11.2-19.0), severe preeclampsia (0.8/10,000, adjusted OR 10.4, 95% CI 7.7-14.2), and intrauterine fetal demise (0.7/10,000, adjusted OR 5.5, 95% CI 3.9-7.8). The most common etiologies of massive blood transfusion were abnormal placentation (26.6% of cases), uterine atony (21.2%), placental abruption (16.7%), and postpartum hemorrhage associated with coagulopathy (15.0%). A disproportionate number of women who received a massive blood transfusion experienced severe morbidity including renal failure, acute respiratory distress syndrome, sepsis, and in-hospital death. Massive blood transfusion was infrequent, regardless of facility size. In the presence of known risk for receipt of massive blood transfusion, women should be informed of this possibility, should deliver in a well-resourced facility if possible, and should receive appropriate blood product preparation and venous access in advance of delivery. : II.
Improving ED specimen TAT using Lean Six Sigma.
Sanders, Janet H; Karr, Tedd
2015-01-01
Lean and Six Sigma are continuous improvement methodologies that have garnered international fame for improving manufacturing and service processes. Increasingly these methodologies are demonstrating their power to also improve healthcare processes. The purpose of this paper is to discuss a case study for the application of Lean and Six Sigma tools in the reduction of turnaround time (TAT) for Emergency Department (ED) specimens. This application of the scientific methodologies uncovered opportunities to improve the entire ED to lab system for the specimens. This case study provides details on the completion of a Lean Six Sigma project in a 1,000 bed tertiary care teaching hospital. Six Sigma's Define, Measure, Analyze, Improve, and Control methodology is very similar to good medical practice: first, relevant information is obtained and assembled; second, a careful and thorough diagnosis is completed; third, a treatment is proposed and implemented; and fourth, checks are made to determine if the treatment was effective. Lean's primary goal is to do more with less work and waste. The Lean methodology was used to identify and eliminate waste through rapid implementation of change. The initial focus of this project was the reduction of turn-around-times for ED specimens. However, the results led to better processes for both the internal and external customers of this and other processes. The project results included: a 50 percent decrease in vials used for testing, a 50 percent decrease in unused or extra specimens, a 90 percent decrease in ED specimens without orders, a 30 percent decrease in complete blood count analysis (CBCA) Median TAT, a 50 percent decrease in CBCA TAT Variation, a 10 percent decrease in Troponin TAT Variation, a 18.2 percent decrease in URPN TAT Variation, and a 2-5 minute decrease in ED registered nurses rainbow draw time. This case study demonstrated how the quantitative power of Six Sigma and the speed of Lean worked in harmony to improve the blood draw process for a 1,000 bed tertiary care teaching hospital. The blood draw process is a standard process used in hospitals to collect blood chemistry and hematology information for clinicians. The methods used in this case study demonstrated valuable and practical applications of process improvement methodologies that can be used for any hospital process and/or service environment. While this is not the first case study that has demonstrated the use of continuous process improvement methodologies to improve a hospital process, it is unique in the way in which it utilizes the strength of the project focussed approach that adheres more to the structure and rigor of Six Sigma and relied less on the speed of lean. Additionally, the application of these methodologies in healthcare is emerging research.
Internal hydraulic loss in a seal-less centrifugal Gyro pump.
Makinouchi, K; Ohara, Y; Sakuma, I; Damm, G; Mizuguchi, K; Jikuya, T; Takatani, S; Noon, G P; Nosé, Y
1994-01-01
A new index "loss factor Z" defined by Eq. 1 was introduced as the absolute expression of the mock loop resistance for testing a nonpulsatile pump. [formula: see text] where gamma is specific gravity of the fluid, g is the acceleration of gravity, delta P is total pressure head, and Q is flow. Z is expected to be constant, regardless of the pumping parameters. Z values obtained in the same mock loop but with different rotary blood pumps were almost identical and were defined as Z0. New methods of analysis of the flow-restrictive conditions of various rotary blood pumps are proposed in this paper: namely, differential loss factor delta Z, and loss factor sensitivity delta Z/delta A. The proposed Z-Q curves demonstrated better performance mapping than the conventional delta P-Q curves. Delta Z is the difference between the Z-Q curves of two different pumps. A is a design parameter of the pump; therefore delta Z/delta A is a quantitative expression of the effect of the design change on the hydraulic performance. These various indices were used to analyze the internal hydraulic loss of a centrifugal pump (Gyro pump). The relationship between its gap size (rotor casing) and hydraulic performance was assessed quantitatively by these indices. In this paper, the derivation processes and above-mentioned indices are described.
Code of Federal Regulations, 2010 CFR
2010-10-01
...), Eskimo, or Aleut blood, or combination thereof. The term includes any Native, as so defined, either or... blood quantum, any citizen of the United States who is regarded as an Alaska Native by the Native... formation of traditional native groups, such as cooperatives, is permitted so long as no large-scale mass...
Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz
2012-01-01
Background The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Materials and methods Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. Results The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. Discussion These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement. PMID:22044958
Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz
2012-01-01
The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement.
Blood pressure-to-height ratio for screening prehypertension and hypertension in Chinese children.
Dong, B; Wang, Z; Wang, H-J; Ma, J
2015-10-01
The diagnosis of hypertension in children is complicated because of the multiple age-, sex- and height-specific thresholds. To simplify the process of diagnosis, blood pressure-to-height ratio (BPHR) was employed in this study. Data were obtained from a Chinese national survey conducted in 2010, and 197 191 children aged 7-17 years were included. High normal and elevated blood pressure (BP) were defined according to the National High Blood Pressure Education Program (NHBPEP) Working Group definition. The optimal thresholds were selected by Youden's index. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and area under the curve (AUC) were assessed for the performance of these thresholds. The systolic and diastolic BPHR thresholds for identifying high normal BP were 0.84/0.55, 0.78/0.50 and 0.75/0.46 for children aged 7-8 years, 9-11 years and 12-17 years, respectively. The corresponding thresholds for identifying elevated BP were 0.87/0.57, 0.81/0.53 and 0.76/0.49, respectively. These proposed thresholds revealed high sensitivity and NPVs, all above 0.96, moderate to high specificity and AUCs, and low PPVs. Our finding suggested the proposed BPHR thresholds were accurate for identifying children without high normal or elevated BP, and could be employed to simplify the procedure of screening prehypertension and hypertension in children.
Saghiri, Mohammad Ali; Asatourian, Armen; Sorenson, Christine M.; Sheibani, Nader
2016-01-01
Introduction Dental pulp regeneration is a part of regenerative endodontics, which includes isolation, propagation, and re-transplantation of stem cells inside the prepared root canal space. The formation of new blood vessels through angiogenesis is mandatory to increase the survival rate of re-transplanted tissues. Angiogenesis is defined as the formation of new blood vessels from preexisting capillaries, which has great importance in pulp regeneration and homeostasis. Here the contribution of human dental pulp stem cells and proangiogenic and antiangiogenic factors to angiogenesis process and regeneration of dental pulp is reviewed. Methods A search was performed on the role of angiogenesis in dental pulp regeneration from January 2005 through April 2014. The recent aspects of the relationship between angiogenesis, human dental pulp stem cells, and proangiogenic and antiangiogenic factors in regeneration of dental pulp were assessed. Results Many studies have indicated an intimate relationship between angiogenesis and dental pulp regeneration. The contribution of stem cells and mechanical and chemical factors to dental pulp regeneration has been previously discussed. Conclusions Angiogenesis is an indispensable process during dental pulp regeneration. The survival of inflamed vital pulp and engineered transplanted pulp tissue are closely linked to the process of angiogenesis at sites of application. However, the detailed regulatory mechanisms involved in initiation and progression of angiogenesis in pulp tissue require investigation. PMID:25649306
[Transfusion supply optimization in multiple-discipline surgical hospital].
Solov'eva, I N; Trekova, N A; Krapivkin, I A
2016-01-01
To define optimal variant of transfusion supply of hospital by blood components and to decrease donor blood expense via application of blood preserving technologies. Donor blood components expense, volume of hemotransfusions and their proportion for the period 2012-2014 were analyzed. Number of recipients of packed red cells, fresh-frozen plasma and packed platelets reduced 18.5%, 25% and 80% respectively. Need for donor plasma decreased 35%. Expense of autologous plasma in cardiac surgery was 76% of overall volume. Preoperative plasma sampling is introduced in patients with aortic aneurysm. Number of cardiac interventions performed without donor blood is increased 7-31% depending on its complexity.
Paper-based CRP Monitoring Devices
NASA Astrophysics Data System (ADS)
Lin, Shang-Chi; Tseng, Chung-Yuh; Lai, Po-Liang; Hsu, Min-Yen; Chu, Shueh-Yao; Tseng, Fan-Gang; Cheng, Chao-Min
2016-12-01
Here, we discuss the development of a paper-based diagnostic device that is inexpensive, portable, easy-to-use, robust, and capable of running simultaneous tests to monitor a relevant inflammatory protein for clinical diagnoses i.e. C-reactive protein (CRP). In this study, we first attempted to make a paper-based diagnostic device via the wax printing method, a process that was used in previous studies. This device has two distinct advantages: 1) reduced manufacturing and assay costs and operation duration via using wax printing method to define hydrophobic boundaries (for fluidic devices or general POC devices); and, 2) the hydrophilicity of filter paper, which is used to purify and chromatographically correct interference caused by whole blood components with a tiny amount of blood sample (only 5 μL). Diagnosis was based on serum stain length retained inside the paper channels of our device. This is a balanced function between surface tension and chromatographic force following immune reactions (CRP assays) with a paper-embedded biomarker.
Staccini, Pascal; Rouger, Philippe
2008-01-01
In order to manage a nationwide assessment program leading to certification of professional competence in blood transfusion throughout France, the National Institute of Blood Transfusion (INTS) and the University of Nice-Sophia Antipolis designed and developed a structured and tutored web-based portfolio. The entire process of certification has been approved by the national healthcare agency (HAS). Eleven assessment programs have been written. The structure of this e-portfolio is based on a matrix of actions defined according to standards of practice. For each action, elements of proof are uploaded by the physician and peer-reviewed by an expert (a tutor) before validation. The electronic portfolio stores all the history of the actions performed by users. This tracking feature generates alerts which are e-mailed to users (physicians and tutors) according to a list of monitored events. After one year of design and development, the application is now being used routinely. PMID:18999167
A review of blood transfusions in a trauma unit for young children.
Salverda, M; Ketharanathan, N; Van Dijk, M; Beltchev, E; Buys, H; Numanoglu, A; Van As, A B
2017-02-27
Trauma is the leading cause of mortality and morbidity worldwide. Blood transfusions play an incremental role in the acute phase, yet practice varies owing to variations in transfusion thresholds and concerns about potential complications, especially in children. To evaluate protocol adherence to blood transfusion thresholds in paediatric trauma patients and determine the degree of blood product wastage, as defined by discarded units. A retrospective, descriptive study of trauma patients (age 0 - 13 years) who received a blood transfusion in the trauma unit at Red Cross War Memorial Children's Hospital, Cape Town, South Africa, over a 5.5-year period (1 January 2009 - 1 July 2014). Haemoglobin (Hb) transfusion thresholds were defined as 10 g/dL for neurotrauma patients and patients requiring skin grafting or a musculocutaneous flap (group 1). All other trauma patients had an Hb transfusion threshold of 7 g/dL (group 2). A total of 144 patients were included (mean age 5.2 years (standard deviation (SD) 3.3), 68.1% male). The mean Hb increase after transfusion was 3.5 g/dL (SD 1.7). Adherence to the transfusion Hb threshold protocol was 96.7% for group 1 v. 34.0% for group 2. No complications were reported. Average blood wastage was 3.5 units per year during the study period. Adherence to paediatric blood transfusion protocol was low in the Hb threshold group <7 g/dL. However, transfusion-related complications and wastage were minimal. Further prospective research is required to determine optimal blood transfusion guidelines for paediatric trauma patients.
NASA Astrophysics Data System (ADS)
Li, Xiang
2016-10-01
All forms of diabetes increase the risk of long-term complications. Blood glucose monitoring is of great importance for controlling diabetes procedure, preventing the complications and improving the patient's life quality. At present, the clinical blood glucose concentration measurement is invasive and could be replaced by noninvasive spectroscopy analytical techniques. The mid-infrared spectral region contains strong characteristic and well-defined absorption bands. Therefore, mid-infrared provides an opportunity for monitoring blood glucose invasively with only a few discrete bonds. Although the blood glucose concentration measurement using mid-infrared spectroscopy has a lot of advantages, the disadvantage is also obvious. The absorption in this infrared region is fundamental molecular group vibration. Absorption intensity is very strong, especially for biological molecules. In this paper, it figures out that the osmosis rate of glucose has a certain relationship with the blood glucose concentration. Therefore, blood glucose concentration could be measured indirectly by measuring the glucose exudate in epidermis layer. Human oral glucose tolerance tests were carried out to verify the correlation of glucose exudation in shallow layer of epidermis layer and blood glucose concentration. As it has been explained above, the mid-infrared spectral region contains well-defined absorption bands, the intensity of absorption peak around 1123 cm-1 was selected to measure the glucose and that around 1170 cm-1 was selected as reference. Ratio of absorption peak intensity was recorded for each set of measurement. The effect and importance of the cleaning the finger to be measured before spectrum measuring are discussed and also verified by experiment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
[The causes of recurrent ulcerative gastroduodenal bleeding].
Lipnitsky, E M; Alekberzade, A V; Gasanov, M R
To explore microcirculatory changes within the first 48 hours after admission, to compare them with clinical manifestations of bleeding and to define the dependence of recurrent bleeding from the therapy. The study included 108 patients with ulcerative gastroduodenal bleeding who were treated at the Clinical Hospital #71 for the period 2012-2014. There were 80 (74.1%) men and 28 (25.9%) women. Age ranged 20-87 years (mean 54.4±16.8 years). Patients younger than 45 years were predominant (33.4%). J. Forrest classification (1974) was used in endoscopic characterization of bleeding. Roccal Prognostic Scale for gastroduodenal bleeding was applied in all patients at admission to assess the risk of possible recurrence. Patients were divided into 2 groups. Group 1 included 53 (49.1%) patients without recurrent bleeding; group 2-55 (50.1%) patients who had recurrent bleeding within the first two days of treatment. Investigation of microcirculation showed the role of vegetative component including blood circulation centralization, blood flow slowing, blood cells redistribution providing sufficient blood oxygenation. By the end of the first day we observed pronounced hemodilution, decreased blood oxygenation, blood flow restructuring with its acceleration above 1 ml/s, violation of tissue oxygenation, signs of hypovolemia. These changes were significantly different from group 2 and associated with circulatory decentralization with possible pulmonary microcirculation disturbances and interstitial edema. This processes contribute to disruption of tissue oxygenation. We assume that recurrent bleeding in group 2 was caused by fluid therapy in larger volumes than it was necessary in this clinical situation. Infusion therapy should be significantly reduced for the debut of gastroduodenal ulcerative bleeding. Sedative therapy is advisable to reduce the influence of central nervous system.
Sengupta
1998-08-01
BACKGROUND: Conventional indices could not define the pathogenesis of pre-eclampsia and its predictability. It has also not been possible to record these indices from the local uteroplacental system where the pathology lies. OBJECTIVE: To investigate the limitations of the currently available blood pressure-flow measuring indices and techniques commonly used in pregnancy.METHOD: Blood pressure and velocity profiles were obtained under various pathophysiological conditions for pregnant and non-pregnant animals and human subjects. The data were analysed using both conventional and computer-based spectral methods. RESULTS: Continuous monitoring of blood pressure and velocity together with their spectral analysis appeared to be a useful sensitive indicator in pregnancy beyond the commonly available conventional analytical method. In high-resistance flow such as in hypertension and in pre-eclampsia, the power amplitude was relatively low at low frequency. Power amplitude remained high at low frequency in normal low-resistance state of pregnancy. CONCLUSION: The results suggest the need to develop a highly sensitive instrumentation whereby any minute variation in mean arterial pressure that is of clinical significance can be measured. Alternatively, analytical advancement, such as use of power spectrum analysers, might prove to be useful and sensitive. Variability of heart rate is an important determinant of the underlying pathophysiology in pregnancy. It is concluded that the heart rate of pre-eclamptics and hypertensives has to increase in order to maintain a constant organic blood flow whereas in normal pregnancy bloow flow can rise even without an incrase in heart rate. Future research should be directed towards blood flow mapping, power spectral analysis and image processing of the blood pressure-flow profile obtained from local and systemic compartments under different pathophysiological conditions of pregnancy.
[Prevalence of iron deficiency].
Dupont, C
2017-05-01
Studies of prévalence in iron deficiency separate iron depletion (defined as decreased blood ferritin) and iron deficiency anemia (defined as blood decrease in both ferritin and hemoglobin). In Europe, most studies are outdated. Prevalence of iron depletion varies from 7 to 18 % and 24 to 36% in toddlers and adolescents, respectively. Prevalence of iron deficiency anemia varies from 2 to 8.5% and 7 to 10% in toddlers and adolescents. In French speaking African countries, Demography Health Surveys show that 80% of children aged 0 to 2 years are anemic, severely for 5 to 9% of them. © 2017 Elsevier Masson SAS. Tous droits réservés.
[Prevalence of and risk factors for hepatitis C in blood donors].
Ladrón-de Guevara, Laura; Gómez, Nicolás; Vázquez-Cantarell, Mariana; García-Méndez, Sergio; Di Silvio, Mauricio
2002-01-01
Determine hepatitis C prevalence and risk factors in blood donors from the Blood Bank at the Centro Médico Nacional 20 de Noviembre ISSSTE, in Mexico City. A total of 41,957 blood donors were included in the study was done from January 1996 to August 2000. To study risk factors, a case-control study cases were defined as blood donors with repeatedly positive anti-hepatitis C virus (HCV) ELISA test. Controls were defined as blood donors with negative anti-HCV ELISA test. All cases were interviewed a second time on HCV infection-associated risk factors. Odd ratio (OR) and confidence interval 95% (CI 95%) were calculated for each risk factoring in a univariate analysis. Multivariate analysis was performed subsequents to determine the independent contribution or each risk factor. HCV crude total prevalence was 0.84%. Risk factors were found in 36.16% anti-HCV-positive blood donors. During the second interview, 30% of sero-positive blood donors recalled one or more risk factors they previously denied. The most important risk factors, found were as follows sexual relations with prostitutes (OR 7.48, CI 95% 1.43-38.92) transfusion (OR 6, CI 95% 2.62-13.72); nasal cocaine use (OR 8.89, CI 95%, 1.01-86.89); dental surgery (OR 8.89, CI 95% 1.01-86.89) and contact with hepatitis-infected subject (OR 3.01, CI 95% 1.17-7.70). Other risk factors did not show a significant association. In this study, we found a crude total prevalence of 0.84%, very close to the prevalence reported in Mexican population by the National Center for Blood Transfusion.
Postoperative Infection in the Setting of Massive Intraoperative Blood Loss.
Leylek, Melike; Poliquin, Vanessa; Al-Wazzan, Ahmad; Dean, Erin; Altman, Alon D
2016-12-01
To determine the local rates of massive intraoperative blood loss and subsequent infectious morbidity for patients undergoing gynaecologic laparotomy. We performed a retrospective chart review of all patients undergoing gynaecologic laparotomy between January 1, 2013 and December 31, 2013 to identify cases of massive intraoperative blood loss (defined as ≥1 L estimated intraoperative blood loss, a postoperative reduction in hemoglobin concentration of ≥40 g/L, or a perioperative blood transfusion). For cases meeting these criteria, we abstracted further data to assess the rate of postoperative infectious morbidity (defined as a positive wound swab culture, positive urine culture, or satisfying the 1991 criteria for systemic inflammatory response syndrome). The rate of massive intraoperative blood loss was 13.5% (n = 69). The average age in this cohort was 50.4 years (range 18-84 years) and the average BMI was 27.9 kg/m 2 . Perioperative transfusion was required in 31.9% (n = 22). Notably, 26.1% of patients (n = 18) met one of our primary endpoints for postoperative infectious morbidity. A further 10.1% (n = 7) had morbidities including hyponatremia, wound dehiscence, intra-abdominal abscess, positive blood cultures, acute respiratory distress syndrome, myocardial infarction, intensive care unit admission, or death. Our rate of massive intraoperative blood loss during gynaecologic laparotomy was found to be 13.5%, and our rate of postoperative infectious morbidity subsequent to massive intraoperative blood loss was 26.1%. Copyright © 2016 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.
Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.
Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus
2016-01-01
Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, P<0.001) and diastolic (r=0.35 versus 0.17, P<0.001) blood pressure. In addition, 2 abnormal childhood/youth blood pressure observations increased the prediction of hypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth. © 2015 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Ostrowski, Z.; Melka, B.; Adamczyk, W.; Rojczyk, M.; Golda, A.; Nowak, A. J.
2016-09-01
In the research a numerical Computational Fluid Dynamics (CFD) model of the pulsatile blood flow was created and analyzed. A real geometry of aorta and its thoracic branches of 8-year old patient diagnosed with a congenital heart defect - coarctation of aorta was used. The inlet boundary condition were implemented as the User Define Function according to measured values of volumetric blood flow. The blood flow was treated as multiphase: plasma, set as the primary fluid phase, was dominant with volume fraction of 0.585 and morphological elements of blood were treated in Euler-Euler approach as dispersed phases (with 90% Red Blood Cells and White Blood Cells as remaining solid volume fraction).
Rebound hyperglycaemia in diabetic cats.
Roomp, Kirsten; Rand, Jacquie
2016-08-01
Rebound hyperglycaemia (also termed Somogyi effect) is defined as hyperglycaemia caused by the release of counter-regulatory hormones in response to insulin-induced hypoglycaemia, and is widely believed to be common in diabetic cats. However, studies in human diabetic patients over the past quarter century have rejected the common occurrence of this phenomenon. Therefore, we evaluated the occurrence and prevalence of rebound hyperglycaemia in diabetic cats. In a retrospective study, 10,767 blood glucose curves of 55 cats treated with glargine using an intensive blood glucose regulation protocol with a median of five blood glucose measurements per day were evaluated for evidence of rebound hyperglycaemic events, defined in two different ways (with and without an insulin resistance component). While biochemical hypoglycaemia occurred frequently, blood glucose curves consistent with rebound hyperglycaemia with insulin resistance was confined to four single events in four different cats. In 14/55 cats (25%), a median of 1.5% (range 0.32-7.7%) of blood glucose curves were consistent with rebound hyperglycaemia without an insulin resistance component; this represented 0.42% of blood glucose curves in both affected and unaffected cats. We conclude that despite the frequent occurrence of biochemical hypoglycaemia, rebound hyperglycaemia is rare in cats treated with glargine on a protocol aimed at tight glycaemic control. For glargine-treated cats, insulin dose should not be reduced when there is hyperglycaemia in the absence of biochemical or clinical evidence of hypoglycaemia. © ISFM and AAFP 2015.
Exaggerated blood pressure response to exercise and late-onset hypertension in young adults.
Yzaguirre, Ignasi; Grazioli, Gonzalo; Domenech, Mónica; Vinuesa, Antonio; Pi, Ramon; Gutierrez, Josep; Coca, Antonio; Brugada, Josep; Sitges, Marta
2017-12-01
Exaggerated blood pressure response (EBPR) during exercise has been associated with an increased risk of incidental systemic hypertension and cardiovascular morbidity; however, there is no consensus definition of EBPR. We aimed to determine which marker best defines EBPR during exercise and to predict the long-term development of hypertension in individuals younger than 50 years. We reviewed 107 exercise tests performed in 1992, applied several reported methods to define EBPR at moderate and maximum exercise, and contacted the patients by telephone 20 years after the test to verify hypertension status. Finally, we determined which definition best predicted incidental hypertension at 20-year follow-up. The mean age of the participants at the time of exercise testing was 25.7±11.1 years. Logistic regression showed a significant association of diastolic blood pressure of more than 95 mmHg at peak exercise and systolic pressure more than 180 mmHg at moderate exercise with new-onset hypertension at 20-year follow-up [odds ratio: 6.3 (2.09-18.9) and odds ratio: 7.09 (2.31-21.7), respectively]. If EBPR was present, as defined by at least one of these parameters, the probability of incidental later onset hypertension was 70%. In our population, diastolic blood pressure of more than 95 mmHg at maximum exercise or systolic blood pressure more than 180 mmHg at moderate-intensity exercise (100 W) were the best predictors of new-onset hypertension at long-term follow-up. Individuals with EBPR according to these criteria should be monitored closely to detect the early development of hypertension.
77 FR 46096 - Statistical Process Controls for Blood Establishments; Public Workshop
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
...] Statistical Process Controls for Blood Establishments; Public Workshop AGENCY: Food and Drug Administration... workshop entitled: ``Statistical Process Controls for Blood Establishments.'' The purpose of this public workshop is to discuss the implementation of statistical process controls to validate and monitor...
The Snail Family in Normal and Malignant Haematopoiesis.
Carmichael, Catherine L; Haigh, Jody J
2017-01-01
Snail family proteins are key inducers of the epithelial-mesenchymal transition (EMT), a critical process required for normal embryonic development. They have also been strongly implicated in regulating the EMT-like processes required for tumour cell invasion, migration, and metastasis. Whether these proteins also contribute to normal blood cell development, however, remains to be clearly defined. Increasing evidence supports a role for the Snail family in regulating cell survival, migration, and differentiation within the haematopoietic system, as well as potentially an oncogenic role in the malignant transformation of haematopoietic stem cells. This review will provide a broad overview of the Snail family, including key aspects of their involvement in the regulation and development of solid organ cancer, as well as a discussion on our current understanding of Snail family function during normal and malignant haematopoiesis. © 2017 S. Karger AG, Basel.
Identification and staining of distinct populations of secretory organelles in astrocytes.
Bezzi, Paola; Volterra, Andrea
2014-05-01
Increasing evidence indicates that astrocytes, the most abundant glial cell type in the brain, respond to an elevation in cytoplasmic calcium concentration ([Ca(2+)]i) by releasing chemical transmitters (also called gliotransmitters) via regulated exocytosis of heterogeneous classes of organelles. By this process, astrocytes exert modulatory influences on neighboring cells and are thought to participate in the control of synaptic circuits and cerebral blood flow. Studying the properties of exocytosis in astrocytes is a challenge, because the cell biological basis of this process is incompletely defined. Astrocytic exocytosis involves multiple populations of secretory vesicles, including synaptic-like microvesicles (SLMVs), dense-core granules (DCGs), and lysosomes. Here we summarize the available information for identifying individual populations of secretory organelles in astrocytes, including DCGs, SLMVs, and lysosomes, and present experimental procedures for specifically staining such populations.
Three-dimensional image contrast using biospeckle
NASA Astrophysics Data System (ADS)
Godinho, Robson Pierangeli; Braga, Roberto A., Jr.
2010-09-01
The biospeckle laser (BSL) has been applied in many areas of knowledge and a variety of approaches has been presented to address the best results in biological and non-biological samples, in fast or slow activities, or else in defined flow of materials or in random activities. The methodologies accounted in the literature consider the apparatus used in the image assembling and the way the collected data is processed. The image processing steps presents in turn a variety of procedures with first or second order statistics analysis, and as well with different sizes of data collected. One way to access the biospeckle in defined flow, such as in capillary blood flow in alive animals, was the adoption of the image contrast technique which uses only one image from the illuminated sample. That approach presents some problems related to the resolution of the image, which is reduced during the image contrast processing. In order to help the visualization of the low resolution image formed by the contrast technique, this work presents the three-dimensional procedure as a reliable alternative to enhance the final image. The work based on a parallel processing, with the generation of a virtual map of amplitudes, and maintaining the quasi-online characteristic of the contrast technique. Therefore, it was possible to generate in the same display the observed material, the image contrast result and in addiction the three-dimensional image with adjustable options of rotation. The platform also offers to the user the possibility to access the 3D image offline.
Vasovagal reactions in whole blood donors at 3 REDS-II blood centers in Brazil
Goncalez, T. T.; Sabino, E. C.; Schlumpf, K.S.; Wright, D.J.; Leao, S.; Sampaio, D.; Takecian, P. L.; Carneiro-Proietti, AB; Murphy, E.; Busch, M.; Custer, B.
2013-01-01
Background In Brazil little is known about adverse reactions during donation and the donor characteristics that may be associated with such events. Donors are offered snacks and fluids prior to donating and are required to consume a light meal after donation. For these reasons the frequency of reactions may be different than those observed in other countries. Methods A cross-sectional study was conducted of eligible whole blood donors at three large blood centers located in Brazil between July 2007 and December 2009. Vasovagal reactions (VVRs) along with donor demographic and biometric data were collected. Reactions were defined as any presyncopal or syncopal event during the donation process. Multivariable logistic regression was performed to identify predictors of VVRs. Results Of 724,861 donor presentations, 16,129 (2.2%) VVRs were recorded. Rates varied substantially between the three centers: 53, 290 and 381 per 10,000 donations in Recife, São Paulo and Belo Horizonte, respectively. Although the reaction rates varied, the donor characteristics associated with VVRs were similar [younger age (18–29), replacement donors, first time donors, low estimated blood volume (EBV)]. In multivariable analysis controlling for differences between the donor populations in each city younger age, first-time donor status and lower EBV were the factors most associated with reactions. Conclusion Factors associated with VVRs in other locations are also evident in Brazil. The difference in VVR rates between the three centers might be due to different procedures for identifying and reporting the reactions. Potential interventions to reduce the risk of reactions in Brazil should be considered. PMID:22073941
Judd, Eric K.; Calhoun, David A.; Warnock, David G.
2015-01-01
Summary Resistant hypertension is a clinically distinct subgroup of hypertension defined by the failure to achieve blood pressure control on optimal dosing of at least 3 antihypertensive medications of different classes, including a diuretic. The pathophysiology of hypertension can be attributed to aldosterone excess in more than 20% of patients with resistant hypertension. Existing dogma attributes the increase in blood pressure seen with increases in aldosterone to its antinatriuretic effects in the distal nephron. However, emerging research, which has identified and has begun to define the function of amiloride-sensitive sodium channels and mineralocorticoid receptors in the systemic vasculature, challenges impaired natriuresis as the sole cause of aldosterone-mediated resistant hypertension. This review integrates these findings to better define the role of the vasculature and aldosterone in the pathophysiology of resistant hypertension. In addition, a brief guide to the treatment of resistant hypertension is presented. PMID:25416662
Judd, Eric K; Calhoun, David A; Warnock, David G
2014-01-01
Resistant hypertension is a clinically distinct subgroup of hypertension defined by the failure to achieve blood pressure control on optimal dosing of at least 3 antihypertensive medications of different classes, including a diuretic. The pathophysiology of hypertension can be attributed to aldosterone excess in more than 20% of patients with resistant hypertension. Existing dogma attributes the increase in blood pressure seen with increases in aldosterone to its antinatriuretic effects in the distal nephron. However, emerging research, which has identified and has begun to define the function of amiloride-sensitive sodium channels and mineralocorticoid receptors in the systemic vasculature, challenges impaired natriuresis as the sole cause of aldosterone-mediated resistant hypertension. This review integrates these findings to better define the role of the vasculature and aldosterone in the pathophysiology of resistant hypertension. In addition, a brief guide to the treatment of resistant hypertension is presented.
Novelli, M D; Barreto, E; Matos, D; Saad, S S; Borra, R C
1997-01-01
The authors present the experimental results of the computerized quantifying of tissular structures involved in the reparative process of colonic anastomosis performed by manual suture and biofragmentable ring. The quantified variables in this study were: oedema fluid, myofiber tissue, blood vessel and cellular nuclei. An image processing software developed at Laboratório de Informática Dedicado à Odontologia (LIDO) was utilized to quantifying the pathognomonic alterations in the inflammatory process in colonic anastomosis performed in 14 dogs. The results were compared to those obtained through traditional way diagnosis by two pathologists in view of counterproof measures. The criteria for these diagnoses were defined in levels represented by absent, light, moderate and intensive which were compared to analysis performed by the computer. There was significant statistical difference between two techniques: the biofragmentable ring technique exhibited low oedema fluid, organized myofiber tissue and higher number of alongated cellular nuclei in relation to manual suture technique. The analysis of histometric variables through computational image processing was considered efficient and powerful to quantify the main tissular inflammatory and reparative changing.
Overweight and cardiovascular risk factors in 4- to 18-year-olds.
Craig, Leone C A; Love, Joan; Ratcliffe, Brian; McNeill, Geraldine
2008-01-01
The objective of this study was to investigate the relationships between overweight and high waist circumference and cardiovascular risk factors in children. We carried out a secondary analysis of data from 1,944 participants of the 'National Diet and Nutrition Survey: young people aged 4-18 years'. Blood pressure and blood lipid levels were compared in overweight versus non-overweight and high versus low waist circumference groups. Overweight was defined using international cut-offs for body mass index. High waist circumference was defined as >or= 91st percentile of UK waist circumference charts. Analyses were done separately by sex and age group (4-10 and 11-18 years for overweight, and 11-17 years for waist circumference). Overweight and high waist circumference were associated with increased systolic blood pressure, mean arterial pressure, low-density lipoprotein cholesterol (LDLC) and triacylglycerol, and decreased high-density lipoprotein cholesterol (HDLC). Those who were both overweight and had a high waist circumference had the highest blood pressure, plasma LDLC and triacylglycerol, and the lowest plasma HDLC. Overweight and high waist circumference were associated with increased blood pressure and a less favourable lipid profile. Children who were both overweight and had a high waist circumference had the most unfavourable cardiovascular risk profile. Both measurements may be useful in identifying children with increased health risks.
Closed continuous-flow centrifuge rotor
Breillatt, Jr., Julian P.; Remenyik, Carl J.; Sartory, Walter K.; Thacker, Louis H.; Penland, William Z.
1976-01-01
A blood separation centrifuge rotor having a generally parabolic core disposed concentrically and spaced apart within a housing having a similarly shaped cavity. Blood is introduced through a central inlet and into a central passageway enlarged downwardly to decrease the velocity of the entrant blood. Septa are disposed inside the central passageway to induce rotation of the entrant blood. A separation chamber is defined between the core and the housing wherein the whole blood is separated into red cell, white cell, and plasma zones. The zones are separated by annular splitter blades disposed within the separation chamber. The separated components are continuously removed through conduits communicating through a face seal to the outside of the rotor.
Kernbach, G; Püschel, K; Brinkmann, B
1986-01-01
This study was performed to examine the relationship between postmortem biochemical values and cause of death. The follow samples were taken from 399 corpses: cerebrospinal fluid (CSF; n = 376, suboccipital), blood (n = 158, femoral vein), and urine (n = 101, at autopsy). (See Table 1 for causes of death) All samples were stored at -80 degrees C. A further 100 samples of blood were later taken and stored at +4 degrees C before testing. Biochemical determinations made were: glucose in CSF, blood, and urine (hexokinase method); lactate (LDH/GPT) and free acetone (HS-gas chromatography) in CSF; hemoglobin A1 in blood (microcolumn technique). In 34 cases fatal diabetic coma was considered verified by morphological and chemical findings. One hundred cases of sudden cardiac death were chosen as the main control group. In 32 of the 34 cases defined above, the value of the formula of Traub (glucose + lactate in CSF) exceeded 415 mg/dl. It is not influenced significantly by hyperglycemia or hyperlactatemia due to factors other than diabetes (i.e., carbon monoxide, asphyxia). After death the value rose till the 30th hpm, then remained stable for at least 1 week. Fatal coma was defined as the ketoacidotic form if free acetone in CSF ranged above 21 mg/l. In these cases, CSF glucose and free acetone correlated positively. Hemoglobin A1 remained stable after death. Its amount was independent from postmortem blood glucose, postmortem interval and total hemoglobin. Furthermore, the manner of storage (-80 degrees or +4 degrees C) had no significant influence on its values. In 29 of 34 cases of fatal coma, Hb A1 exceeded 12.1%. Analysis of urine glucose showed elevated levels (over 500 mg/dl) in diabetic comas. On conclusion, fatal diabetic coma seems indicated as the cause of death if measured values of postmortem biochemistry exceed the following limits: CSF-Traub 415 mg/dl, free acetone (CSF) 21 mg/l; Hb A1 12.1%; urine glucose 500 mg/dl. Most important are the Traub formula and hemoglobin A1. Usually, in fatal coma both values are elevated. If both of them are normal, diabetic coma can nearly be excluded. Combined evaluation of all values is absolutely necessary. Morphology must also always be taken into account. Consequently, a diagnosis of fatal coma can be obtained by a process of elimination.
Student measurement of blood pressure using a simulator arm compared with a live subject's arm.
Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L
2010-06-15
To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.
Process mining is an underutilized clinical research tool in transfusion medicine.
Quinn, Jason G; Conrad, David M; Cheng, Calvino K
2017-03-01
To understand inventory performance, transfusion services commonly use key performance indicators (KPIs) as summary descriptors of inventory efficiency that are graphed, trended, and used to benchmark institutions. Here, we summarize current limitations in KPI-based evaluation of blood bank inventory efficiency and propose process mining as an ideal methodology for application to inventory management research to improve inventory flows and performance. The transit of a blood product from inventory receipt to final disposition is complex and relates to many internal and external influences, and KPIs may be inadequate to fully understand the complexity of the blood supply chain and how units interact with its processes. Process mining lends itself well to analysis of blood bank inventories, and modern laboratory information systems can track nearly all of the complex processes that occur in the blood bank. Process mining is an analytical tool already used in other industries and can be applied to blood bank inventory management and research through laboratory information systems data using commercial applications. Although the current understanding of real blood bank inventories is value-centric through KPIs, it potentially can be understood from a process-centric lens using process mining. © 2017 AABB.
[The legal status of blood's therapeutic products and consequences].
Thibert, J-B
2016-05-01
The first testimonies of humanity show a constant: blood was always surrounded with a sacred fascination. For years, it was not useful to define a legal status for blood, but healthy crisis, medical practices, had led to answer this question in a context of legal protection of human dignity and rights. Actually, the legal frame is moving and to know those statuses is helpful for a better understanding of the changes. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Hermo, Louis; Pelletier, R-Marc; Cyr, Daniel G; Smith, Charles E
2010-04-01
In the testis, cell adhesion and junctional molecules permit specific interactions and intracellular communication between germ and Sertoli cells and apposed Sertoli cells. Among the many adhesion family of proteins, NCAM, nectin and nectin-like, catenins, and cadherens will be discussed, along with gap junctions between germ and Sertoli cells and the many members of the connexin family. The blood-testis barrier separates the haploid spermatids from blood borne elements. In the barrier, the intercellular junctions consist of many proteins such as occludin, tricellulin, and claudins. Changes in the expression of cell adhesion molecules are also an essential part of the mechanism that allows germ cells to move from the basal compartment of the seminiferous tubule to the adluminal compartment thus crossing the blood-testis barrier and well-defined proteins have been shown to assist in this process. Several structural components show interactions between germ cells to Sertoli cells such as the ectoplasmic specialization which are more closely related to Sertoli cells and tubulobulbar complexes that are processes of elongating spermatids embedded into Sertoli cells. Germ cells also modify several Sertoli functions and this also appears to be the case for residual bodies. Cholesterol plays a significant role during spermatogenesis and is essential for germ cell development. Lastly, we list genes/proteins that are expressed not only in any one specific generation of germ cells but across more than one generation. Copyright 2009 Wiley-Liss, Inc.
Powell, Anne E; Anderson, Eric C; Davies, Paige S; Silk, Alain D; Pelz, Carl; Impey, Soren; Wong, Melissa H
2011-02-15
The most deadly phase in cancer progression is attributed to the inappropriate acquisition of molecular machinery leading to metastatic transformation and spread of disease to distant organs. Although it is appreciated that metastasis involves epithelial-mesenchymal interplay, the underlying mechanism defining this process is poorly understood. Specifically, how cancer cells evade immune surveillance and gain the ability to navigate the circulatory system remains a focus. One possible mechanism underlying metastatic conversion is fusion between blood-derived immune cells and cancer cells. While this notion is a century old, in vivo evidence that cell fusion occurs within tumors and imparts genetic or physiologic changes remains controversial. We have previously demonstrated in vivo cell fusion between blood cells and intestinal epithelial cells in an injury setting. Here, we hypothesize that immune cells, such as macrophages, fuse with tumor cells imparting metastatic capabilities by transferring their cellular identity. We used parabiosis to introduce fluorescent-labeled bone marrow-derived cells to mice with intestinal tumors, finding that fusion between circulating blood-derived cells and tumor epithelium occurs during the natural course of tumorigenesis. Moreover, we identify the macrophage as a key cellular partner for this process. Interestingly, cell fusion hybrids retain a transcriptome identity characteristic of both parental derivatives, while also expressing a unique subset of transcripts. Our data supports the novel possibility that tumorigenic cell fusion may impart physical behavior attributed to migratory macrophages, including navigation of circulation and immune evasion. As such, cell fusion may represent a promising novel mechanism underlying the metastatic conversion of cancer cells. ©2011 AACR.
Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.
Lo, Y C; Armbruster, David A
2012-04-01
Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.
Wnt/β-Catenin Signaling Determines the Vasculogenic Fate of Postnatal Mesenchymal Stem Cells.
Zhang, Zhaocheng; Nör, Felipe; Oh, Min; Cucco, Carolina; Shi, Songtao; Nör, Jacques E
2016-06-01
Vasculogenesis is the process of de novo blood vessel formation observed primarily during embryonic development. Emerging evidence suggest that postnatal mesenchymal stem cells are capable of recapitulating vasculogenesis when these cells are engaged in tissue regeneration. However, the mechanisms underlining the vasculogenic differentiation of mesenchymal stem cells remain unclear. Here, we used stem cells from human permanent teeth (dental pulp stem cells [DPSC]) or deciduous teeth (stem cells from human exfoliated deciduous teeth [SHED]) as models of postnatal primary human mesenchymal stem cells to understand mechanisms regulating their vasculogenic fate. GFP-tagged mesenchymal stem cells seeded in human tooth slice/scaffolds and transplanted into immunodeficient mice differentiate into human blood vessels that anastomize with the mouse vasculature. In vitro, vascular endothelial growth factor (VEGF) induced the vasculogenic differentiation of DPSC and SHED via potent activation of Wnt/β-catenin signaling. Further, activation of Wnt signaling is sufficient to induce the vasculogenic differentiation of postnatal mesenchymal stem cells, while Wnt inhibition blocked this process. Notably, β-catenin-silenced DPSC no longer differentiate into endothelial cells in vitro, and showed impaired vasculogenesis in vivo. Collectively, these data demonstrate that VEGF signaling through the canonical Wnt/β-catenin pathway defines the vasculogenic fate of postnatal mesenchymal stem cells. Stem Cells 2016;34:1576-1587. © 2016 AlphaMed Press.
Multiple Perspectivism in James Welch's "Winter in the Blood" and "The Death of Jim Loney"
ERIC Educational Resources Information Center
Larson, Sidner
2007-01-01
James Welch's "Winter in the Blood" (1974) and "The Death of Jim Loney" (1979) are excellent examples of work that remains essentially misunderstood throughout some three decades of interpretation. Attempts to define these two books in terms of mainstream modernism notwithstanding, they represent a phenomenon not unlike aspects of American folk…
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Plasma. 640.30 Section 640.30 Food and Drugs FOOD... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.30 Plasma. (a) Proper name and definition. The proper name of this component is Plasma. The component is defined as: (1) The fluid portion of one unit...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Plasma. 640.30 Section 640.30 Food and Drugs FOOD... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.30 Plasma. (a) Proper name and definition. The proper name of this component is Plasma. The component is defined as: (1) The fluid portion of one unit...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Plasma. 640.30 Section 640.30 Food and Drugs FOOD... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.30 Plasma. (a) Proper name and definition. The proper name of this component is Plasma. The component is defined as: (1) The fluid portion of one unit...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Plasma. 640.30 Section 640.30 Food and Drugs FOOD... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.30 Plasma. (a) Proper name and definition. The proper name of this component is Plasma. The component is defined as: (1) The fluid portion of one unit...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Plasma. 640.30 Section 640.30 Food and Drugs FOOD... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.30 Plasma. (a) Proper name and definition. The proper name of this component is Plasma. The component is defined as: (1) The fluid portion of one unit...
Afrane, Yaw A; Zhou, Guofa; Githeko, Andrew K; Yan, Guiyun
2014-10-15
In African highland areas where endemicity of malaria varies greatly according to altitude and topography, parasitaemia accompanied by fever may not be sufficient to define an episode of clinical malaria in endemic areas. To evaluate the effectiveness of malaria interventions, age-specific case definitions of clinical malaria needs to be determined. Cases of clinical malaria through active case surveillance were quantified in a highland area in Kenya and defined clinical malaria for different age groups. A cohort of over 1,800 participants from all age groups was selected randomly from over 350 houses in 10 villages stratified by topography and followed for two-and-a-half years. Participants were visited every two weeks and screened for clinical malaria, defined as an individual with malaria-related symptoms (fever [axillary temperature≥37.5°C], chills, severe malaise, headache or vomiting) at the time of examination or 1-2 days prior to the examination in the presence of a Plasmodium falciparum positive blood smear. Individuals in the same cohort were screened for asymptomatic malaria infection during the low and high malaria transmission seasons. Parasite densities and temperature were used to define clinical malaria by age in the population. The proportion of fevers attributable to malaria was calculated using logistic regression models. Incidence of clinical malaria was highest in valley bottom population (5.0% cases per 1,000 population per year) compared to mid-hill (2.2% cases per 1,000 population per year) and up-hill (1.1% cases per 1,000 population per year) populations. The optimum cut-off parasite densities through the determination of the sensitivity and specificity showed that in children less than five years of age, 500 parasites per μl of blood could be used to define the malaria attributable fever cases for this age group. In children between the ages of 5-14, a parasite density of 1,000 parasites per μl of blood could be used to define the malaria attributable fever cases. For individuals older than 14 years, the cut-off parasite density was 3,000 parasites per μl of blood. Clinical malaria case definitions are affected by age and endemicity, which needs to be taken into consideration during evaluation of interventions.
Bragg, Stefanie A; Armstrong, Kristie C; Xue, Zi-Ling
2012-08-15
A new process to pretreat blood samples has been developed. This process combines the Advanced Oxidation Process (AOP) treatment (using H(2)O(2) and UV irradiation) with acid deactivation of the enzyme catalase in blood. A four-cell reactor has been designed and built in house. The effect of pH on the AOP process has been investigated. The kinetics of the pretreatment process shows that at high C(H(2)O(2),t=0), the reaction is zeroth order with respect to C(H(2)O(2)) and first order with respect to C(blood). The rate limiting process is photon flux from the UV lamp. Degradation of whole blood has been compared with that of pure hemoglobin samples. The AOP pretreatment of the blood samples has led to the subsequent determination of chromium and zinc concentrations in the samples using electrochemical methods. Copyright © 2012 Elsevier B.V. All rights reserved.
Real-time measurement of renal blood flow in healthy subjects using contrast-enhanced ultrasound.
Kalantarinia, Kambiz; Belcik, J Todd; Patrie, James T; Wei, Kevin
2009-10-01
Current methods for measuring renal blood flow (RBF) are time consuming and not widely available. Contrast-enhanced ultrasound (CEU) is a safe and noninvasive imaging technique suitable for assessment of tissue blood flow, which has been used clinically to assess myocardial blood flow. We tested the utility of CEU in monitoring changes in RBF in healthy volunteers. We utilized CEU to monitor the expected increase in RBF following a high protein meal in healthy adults. Renal cortical perfusion was assessed by CEU using low mechanical index (MI) power modulation Angio during continuous infusions of Definity. Following destruction of tissue microbubbles using ultrasound at a MI of 1.0, the rate of tissue replenishment with microbubbles and the plateau acoustic intensity (AI) were used to estimate the RBF velocity and cortical blood volume, respectively. Healthy adults (n = 19, mean age 26.6 yr) were enrolled. The A.beta parameter of CEU, representing mean RBF increased by 42.8%from a baseline of 17.05 +/- 6.23 to 23.60 +/- 6.76 dB/s 2 h after the ingestion of the high-protein meal (P = 0.002). Similarly, there was a 37.3%increase in the beta parameter, representing the geometric mean of blood velocity after the high protein meal (P < 0.001). The change in cortical blood volume was not significant (P = 0.89). Infusion time of Definity was 6.3 +/- 2.0 min. The ultrasound contrast agent was tolerated well with no serious adverse events. CEU is a fast, noninvasive, and practical imaging technique that may be useful for monitoring renal blood velocity, volume, and flow.
Distributed modeling of diffusive solute transport in peritoneal dialysis.
Waniewski, Jacek
2002-01-01
The diffusive transport between blood and an ex-tissue medium (dialysis fluid) is evaluated using a mathematical model that takes into account the (quasicontinuous) distribution of capillaries within the tissue at various distances from the tissue surface, and includes diffusive-convective transport through the capillary wall and lymphatic absorption from the tissue. General formulas for solute penetration depth, lambda, and for the diffusive mass transport coefficient for the transport between blood and dialysis fluid, K(BD), are provided in terms of local transport coefficients for capillary wall, tissue, and lymphatic absorption. For pure diffusive transport between blood and dialysis fluid and thick tissue layers (i.e., if the solute penetration depth is much lower than the tissue thickness) these formulas yield previously known expressions. It is shown that apparent tissue layers, with widths lambdaTBL and lambdaT, respectively, may be defined according to the values of local transport parameters in such a way that K(BD) is equal to the solute clearance K(TBL) from the tissue by blood and lymph for a layer with width lambdaTBL or to the solute clearance K(T) from blood to dialysate by diffusion through the tissue layer with width lambdaT. For tissue layers with width much higher than the penetration depth: lambdaT approximately = lambdaTBL approximately = lambda. These characteristic width lengths depend on the transport parameters (and thus on the size) of solutes. Effective blood flow, which may be related to the exchange of the solute between blood and dialysate, is defined using an analogy to the extraction/absorption coefficients for blood-tissue exchange. Various approximations for the distributed model formula for diffusive mass transport coefficient (K(BD)) are possible. The appropriate range for their application is obtained from the general formula.
Ernst, D; Clerc, J; Decullier, E; Gavanier, G; Dupuis, O
2012-10-01
At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward. Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results. The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8-46.3]; P<0.0001) led to non-valid samples, when only 11.3% of programmed caesarians (IC 95% [4.3-18.2]; P<0.0001) led to non-valid samples. Umbilical cord blood analysis were significantly less validated during emergency caesarians. Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2012 CFR
2012-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Processing system for frozen blood. 864.9145...
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2014 CFR
2014-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Processing system for frozen blood. 864.9145...
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2010 CFR
2010-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Processing system for frozen blood. 864.9145...
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2013 CFR
2013-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Processing system for frozen blood. 864.9145...
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2011 CFR
2011-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Processing system for frozen blood. 864.9145...
Hjellvik, Vidar; Sakshaug, Solveig; Strøm, Hanne
2012-01-01
Obesity, hypertension, and hypertriglyceridemia are important risk factors for type 2 diabetes (T2D). We wanted to assess the risk associated with these three factors alone and in combination, and the relative importance of these and several other risk factors (eg, nonfasting glucose) as predictors of T2D. Risk factors in a Norwegian population (n = 109,796) aged 40-45 years were measured in health studies in 1995-1999. Blood glucose-lowering drugs dispensed in 2004-2009 were used to estimate the incidence of T2D. Groups based on combinations of body mass index (BMI), diastolic blood pressure, and triglycerides were defined by using the 50% and 90% quantiles for each variable for men and women. The relative importance of BMI, triglycerides, total cholesterol, high-density lipoprotein cholesterol, glucose, blood pressure, and year of birth for predicting T2D was assessed using deviance from univariate and multivariate logistic regression models. Height, weight, and blood pressure were measured. All biomarkers were measured in nonfasting blood samples. In the various groups of BMI, triglycerides, and diastolic blood pressure, the incidence of T2D ranged from 0.5% to 19.7% in men and from 0.15% to 21.8% in women. BMI was the strongest predictor of incident T2D, followed by triglyceride levels in women and glucose levels in men. The inclusion of risk factors other than BMI, glucose, triglycerides, and blood pressure in multivariate models only marginally improved the prediction. BMI was the strongest predictor of type 2 diabetes. At defined levels of BMI, the incidence of T2D varied substantially with triglyceride levels and blood pressure. Thus, controlling triglycerides and blood pressure in middle-aged individuals should be targeted to prevent later onset of T2D.
Tsai, Pei-Jiun; Wang, Hwai-Shi; Lin, Chi-Hung; Weng, Zen-Chung; Chen, Tien-Hua; Shyu, Jia-Fwu
2014-01-01
We studied the process of trans-differentiation of human bone marrow mesenchymal stem cells (hBM-MSCs) into insulin-producing cells. Streptozotocin (STZ)-induced diabetic rat model was used to study the effect of portal vein transplantation of these insulin-producing cells on blood sugar levels. The BM-MSCs were differentiated into insulin-producing cells under defined conditions. Real-time PCR, immunocytochemistry and glucose challenge were used to evaluate in vitro differentiation. Flow cytometry showed that hBM-MSCs were strongly positive for CD44, CD105 and CD73 and negative for hematopoietic markers CD34, CD38 and CD45. Differentiated cells expressed C-peptide as well as β-cells specific genes and hormones. Glucose stimulation increased C-peptide secretion in these cells. The insulin-producing, differentiated cells were transplanted into the portal vein of STZ-induced diabetic rats using a Port-A catheter. The insulin-producing cells were localized in the liver of the recipient rat and expressed human C-peptide. Blood glucose levels were reduced in diabetic rats transplanted with insulin-producing cells. We concluded that hBM-MSCs could be trans-differentiated into insulin-producing cells in vitro. Portal vein transplantation of insulin-producing cells alleviated hyperglycemia in diabetic rats.
Blood trace metals in a sporadic amyotrophic lateral sclerosis geographical cluster.
De Benedetti, Stefano; Lucchini, Giorgio; Del Bò, Cristian; Deon, Valeria; Marocchi, Alessandro; Penco, Silvana; Lunetta, Christian; Gianazza, Elisabetta; Bonomi, Francesco; Iametti, Stefania
2017-06-01
Amyotrophic lateral sclerosis (ALS) is a fatal disorder with unknown etiology, in which genetic and environmental factors interplay to determine the onset and the course of the disease. Exposure to toxic metals has been proposed to be involved in the etiology of the disease either through a direct damage or by promoting oxidative stress. In this study we evaluated the concentration of a panel of metals in serum and whole blood of a small group of sporadic patients, all living in a defined geographical area, for which acid mine drainage has been reported. ALS prevalence in this area is higher than in the rest of Italy. Results were analyzed with software based on artificial neural networks. High concentrations of metals (in particular Se, Mn and Al) were associated with the disease group. Arsenic serum concentration resulted lower in ALS patients, but it positively correlated with disease duration. Comet assay was performed to evaluate endogenous DNA damage that resulted not different between patients and controls. Up to now only few studies considered geographically well-defined clusters of ALS patients. Common geographical origin among patients and controls gave us the chance to perform metallomic investigations under comparable conditions of environmental exposure. Elaboration of these data with software based on machine learning processes has the potential to be extremely useful to gain a comprehensive view of the complex interactions eventually leading to disease, even in a small number of subjects.
Campion, Thomas R.; Waitman, Lemuel R.; May, Addison K.; Ozdas, Asli; Lorenzi, Nancy M.; Gadd, Cynthia S.
2009-01-01
Introduction: Evaluations of computerized clinical decision support systems (CDSS) typically focus on clinical performance changes and do not include social, organizational, and contextual characteristics explaining use and effectiveness. Studies of CDSS for intensive insulin therapy (IIT) are no exception, and the literature lacks an understanding of effective computer-based IIT implementation and operation. Results: This paper presents (1) a literature review of computer-based IIT evaluations through the lens of institutional theory, a discipline from sociology and organization studies, to demonstrate the inconsistent reporting of workflow and care process execution and (2) a single-site case study to illustrate how computer-based IIT requires substantial organizational change and creates additional complexity with unintended consequences including error. Discussion: Computer-based IIT requires organizational commitment and attention to site-specific technology, workflow, and care processes to achieve intensive insulin therapy goals. The complex interaction between clinicians, blood glucose testing devices, and CDSS may contribute to workflow inefficiency and error. Evaluations rarely focus on the perspective of nurses, the primary users of computer-based IIT whose knowledge can potentially lead to process and care improvements. Conclusion: This paper addresses a gap in the literature concerning the social, organizational, and contextual characteristics of CDSS in general and for intensive insulin therapy specifically. Additionally, this paper identifies areas for future research to define optimal computer-based IIT process execution: the frequency and effect of manual data entry error of blood glucose values, the frequency and effect of nurse overrides of CDSS insulin dosing recommendations, and comprehensive ethnographic study of CDSS for IIT. PMID:19815452
A CZT-based blood counter for quantitative molecular imaging.
Espagnet, Romain; Frezza, Andrea; Martin, Jean-Pierre; Hamel, Louis-André; Lechippey, Laëtitia; Beauregard, Jean-Mathieu; Després, Philippe
2017-12-01
Robust quantitative analysis in positron emission tomography (PET) and in single-photon emission computed tomography (SPECT) typically requires the time-activity curve as an input function for the pharmacokinetic modeling of tracer uptake. For this purpose, a new automated tool for the determination of blood activity as a function of time is presented. The device, compact enough to be used on the patient bed, relies on a peristaltic pump for continuous blood withdrawal at user-defined rates. Gamma detection is based on a 20 × 20 × 15 mm 3 cadmium zinc telluride (CZT) detector, read by custom-made electronics and a field-programmable gate array-based signal processing unit. A graphical user interface (GUI) allows users to select parameters and easily perform acquisitions. This paper presents the overall design of the device as well as the results related to the detector performance in terms of stability, sensitivity and energy resolution. Results from a patient study are also reported. The device achieved a sensitivity of 7.1 cps/(kBq/mL) and a minimum detectable activity of 2.5 kBq/ml for 18 F. The gamma counter also demonstrated an excellent stability with a deviation in count rates inferior to 0.05% over 6 h. An energy resolution of 8% was achieved at 662 keV. The patient study was conclusive and demonstrated that the compact gamma blood counter developed has the sensitivity and the stability required to conduct quantitative molecular imaging studies in PET and SPECT.
Benchmarking: applications to transfusion medicine.
Apelseth, Torunn Oveland; Molnar, Laura; Arnold, Emmy; Heddle, Nancy M
2012-10-01
Benchmarking is as a structured continuous collaborative process in which comparisons for selected indicators are used to identify factors that, when implemented, will improve transfusion practices. This study aimed to identify transfusion medicine studies reporting on benchmarking, summarize the benchmarking approaches used, and identify important considerations to move the concept of benchmarking forward in the field of transfusion medicine. A systematic review of published literature was performed to identify transfusion medicine-related studies that compared at least 2 separate institutions or regions with the intention of benchmarking focusing on 4 areas: blood utilization, safety, operational aspects, and blood donation. Forty-five studies were included: blood utilization (n = 35), safety (n = 5), operational aspects of transfusion medicine (n = 5), and blood donation (n = 0). Based on predefined criteria, 7 publications were classified as benchmarking, 2 as trending, and 36 as single-event studies. Three models of benchmarking are described: (1) a regional benchmarking program that collects and links relevant data from existing electronic sources, (2) a sentinel site model where data from a limited number of sites are collected, and (3) an institutional-initiated model where a site identifies indicators of interest and approaches other institutions. Benchmarking approaches are needed in the field of transfusion medicine. Major challenges include defining best practices and developing cost-effective methods of data collection. For those interested in initiating a benchmarking program, the sentinel site model may be most effective and sustainable as a starting point, although the regional model would be the ideal goal. Copyright © 2012 Elsevier Inc. All rights reserved.
Morphology of drying blood pools
NASA Astrophysics Data System (ADS)
Laan, Nick; Smith, Fiona; Nicloux, Celine; Brutin, David; D-Blood project Collaboration
2016-11-01
Often blood pools are found on crime scenes providing information concerning the events and sequence of events that took place on the scene. However, there is a lack of knowledge concerning the drying dynamics of blood pools. This study focuses on the drying process of blood pools to determine what relevant information can be obtained for the forensic application. We recorded the drying process of blood pools with a camera and measured the weight. We found that the drying process can be separated into five different: coagulation, gelation, rim desiccation, centre desiccation, and final desiccation. Moreover, we found that the weight of the blood pool diminishes similarly and in a reproducible way for blood pools created in various conditions. In addition, we verify that the size of the blood pools is directly related to its volume and the wettability of the surface. Our study clearly shows that blood pools dry in a reproducible fashion. This preliminary work highlights the difficult task that represents blood pool analysis in forensic investigations, and how internal and external parameters influence its dynamics. We conclude that understanding the drying process dynamics would be advancement in timeline reconstitution of events. ANR funded project: D-Blood Project.
ERIC Educational Resources Information Center
Leith, David E.
1976-01-01
Provides background information, defining areas within organ systems where physiological waterfalls exist. Describes pressure-flow relationships of elastic tubes (blood vessels, airways, renal tubules, various ducts). (CS)
Estimation in a semi-Markov transformation model
Dabrowska, Dorota M.
2012-01-01
Multi-state models provide a common tool for analysis of longitudinal failure time data. In biomedical applications, models of this kind are often used to describe evolution of a disease and assume that patient may move among a finite number of states representing different phases in the disease progression. Several authors developed extensions of the proportional hazard model for analysis of multi-state models in the presence of covariates. In this paper, we consider a general class of censored semi-Markov and modulated renewal processes and propose the use of transformation models for their analysis. Special cases include modulated renewal processes with interarrival times specified using transformation models, and semi-Markov processes with with one-step transition probabilities defined using copula-transformation models. We discuss estimation of finite and infinite dimensional parameters of the model, and develop an extension of the Gaussian multiplier method for setting confidence bands for transition probabilities. A transplant outcome data set from the Center for International Blood and Marrow Transplant Research is used for illustrative purposes. PMID:22740583
Leiba, Adi; Baur, Dorothee M; Kales, Stefanos N
2013-01-01
Different studies have yielded conflicting results regarding the association of hypertensive response to exercise and cardiovascular morbidity. We compared two different definitions of exaggerated hypertensive response to exercise and their association with cardio-respiratory fitness in a population of healthy firefighters. We examined blood pressure response to exercise in 720 normotensive male career firefighters. Fitness was measured as peak metabolic equivalent tasks (METs) achieved during maximal exercise treadmill tests. Abnormal hypertensive response was defined either as systolic blood pressure ≥ 200 mm Hg; or alternatively, as responses falling in the upper tertile of blood pressure change from rest to exertion, divided by the maximal workload achieved. Using the simple definition of a 200 mm Hg cutoff at peak exercise less fit individuals (METs ≤ 12) were protected from an exaggerated hypertensive response (OR 0.45, 95%CI 0.30-0.67). However, using the definition of exercise-induced hypertension that corrects for maximal workload, less fit firefighters had almost twice the risk (OR 1.8, 95%CI 1.3-2.47). Blood pressure change corrected for maximal workload is better correlated with cardiorespiratory fitness. Systolic blood pressure elevation during peak exercise likely represents an adaptive response, whereas elevation out of proportion to the maximal workload may indicate insufficient vasodilation and a maladaptive response. Prospective studies are needed to best define exaggerated blood pressure response to exercise. Copyright © 2013 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Zotova, N V; Chereshnev, V A; Gusev, E Yu
2016-01-01
We defined Systemic inflammation (SI) as a "typical, multi-syndrome, phase-specific pathological process, developing from systemic damage and characterized by the total inflammatory reactivity of endotheliocytes, plasma and blood cell factors, connective tissue and, at the final stage, by microcirculatory disorders in vital organs and tissues." The goal of the work: to determine methodological approaches and particular methodical solutions for the problem of identification of SI as a common pathological process. SI can be defined by the presence in plasma of systemic proinflammatory cell stress products-cytokines and other inflammatory mediators, and also by the complexity of other processes signs. We have developed 2 scales: 1) The Reactivity Level scale (RL)-from 0 to 5 points: 0-normal level; RL-5 confirms systemic nature of inflammatory mediator release, and RL- 2-4 defines different degrees of event probability. 2) The SI scale, considering additional criteria along with RL, addresses more integral criteria of SI: the presence of ≥ 5 points according to the SI scale proves the high probability of SI developing. To calculate the RL scale, concentrations of 4 cytokines (IL-6, IL-8, IL-10, TNF-α) and C-reactive protein in plasma were examined. Additional criteria of the SI scale were the following: D-dimers>500ng/ml, cortisol>1380 or <100nmol/l, troponin I≥0.2ng/ml and/or myoglobin≥800ng/ml. 422 patients were included in the study with different septic (n-207) and aseptic (n-215) pathologies. In 190 cases (of 422) there were signs of SI (lethality 38.4%, n-73). In only 5 of 78 cases, lethality was not confirmed by the presence of SI. SI was registered in 100% of cases with septic shock (n-31). There were not significant differences between AU-ROC of CR, SI scale and SOFA to predict death in patients with sepsis and trauma.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
... hematopoietic stem cells (HSCs) within peripheral blood in the definition of ``bone marrow.'' This would clarify... of whether they were recovered directly from bone marrow (by aspiration) or from peripheral blood (by... consideration.'' ``Human organ'' is defined to include ``bone marrow * * * or any subpart thereof'' or any organ...
ERIC Educational Resources Information Center
Allen, Katherine R.; Blieszner, Rosemary; Roberto, Karen A.
2011-01-01
To identify perspectives on the roles of extended family and fictive kin, the authors conducted a qualitative analysis of in-depth interviews with 45 older adults diverse in gender, race, and class. Five strategies of kin reinterpretation were found. Kin promotion defined a distant blood relative as a closer blood relative. Kin exchange…
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.68 Processing. (a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.68 Processing. (a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.68 Processing. (a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.68 Processing. (a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for...
17 CFR 230.501 - Definitions and terms used in Regulation D.
Code of Federal Regulations, 2011 CFR
2011-04-01
... following categories, at the time of the sale of the securities to that person: (1) Any bank as defined in... plan fiduciary, as defined in section 3(21) of such act, which is either a bank, savings and loan... relative of the purchaser representative by blood, marriage or adoption and not more remote than a first...
2015-10-01
screening. The project requires the use of serum samples obtained from at-risk subjects (heavy smokers with defined characteristics) undergoing...screening. The project requires the use of serum samples obtained from at-risk subjects (heavy smokers with defined characteristics) that were collected
An overview of the endocrine and metabolic changes in manned space flight
NASA Technical Reports Server (NTRS)
Leach, C. S.
1981-01-01
Analyses of endocrinological and metabolic data from humans during spaceflight, particularly the Skylab crews, are summarized to define the levels of knowledge of these processes and the techniques for studying them. The glomerular filtration rate was tested by urine and blood samples, yielding indications of a creatinine clearance increase. The mechanisms for an increase of free water clearance, implying an increase of antidiuretic hormone, are uncertain, and tests are also under way to evaluate the role of prostaglandins in-flight, to account for decreases in catecholamine excretion. Bone mineral losses of 7.9% were observed at the end of 84 days, and processes are suggested for the calcium metabolism. Finally, the observation of almost universal weight loss among space crewmembers is examined, and a loss of muscle tone due to decreased metabolic efficiency is cited as a feature of long duration spaceflight.
[Evaluation of cytomegalovirus quantification in blood by the R-gene real-time PCR test].
Marque-Juillet, S; Touzard, A; Monnier, S; Fernand-Laurent, C; Therby, A; Rigaudeau, S; Harzic, M
2010-04-01
Diagnosing the presence of cytomegalovirus (CMV) in the blood of immunodepressed patients is often done by quantitative polymerase chain reaction (Q-PCR) even though the reference method remains the antigenemia pp65 (Ag-pp65) test. To define the predictive value of the Q-PCR in the diagnosis of CMV disease and assess treatment efficacy using the CMV R-gene test. To compare the Q-PCR results and feasibility with those of the Ag-pp65 test. The Q-PCR was performed in 34 whole blood samples (frozen at -80 degrees C until use) from five patients diagnosed with CMV disease, defined as the presence of clinical signs and Ag-pp65 in the nuclei of more than two cells. After extraction, viral DNA was quantified in each sample using the Q-PCR CMV R-gene kit according to the manufacturer's instructions. Immediately after blood was drawn, the Ag-pp65 test had been performed in 32 samples using CINAkit (Argene). The 16 samples positive by the Ag-pp65 test were also positive by PCR; six samples negative by the Ag-pp65 test were positive by PCR; and the remaining 10 samples were negative by both techniques. During treatment, the two markers' kinetics were similar. The CMV R-gene test has a predictive value as good as that of the Ag-pp65 test but is fast and easier to use. A prospective study with a greater number of patients is needed to define the prediction threshold for CMV disease. Copyright 2009 Elsevier Masson SAS. All rights reserved.
An optical approach for non-invasive blood clot testing
NASA Astrophysics Data System (ADS)
Kalchenko, Vyacheslav; Brill, Alexander; Fine, Ilya; Harmelin, Alon
2007-02-01
Physiological blood coagulation is an essential biological process. Current tests for plasma coagulation (clotting) need to be performed ex vivo and require fresh blood sampling for every test. A recently published work describes a new, noninvasive, in vivo approach to assess blood coagulation status during mechanical occlusion1. For this purpose, we have tested this approach and applied a controlled laser beam to blood micro-vessels of the mouse ear during mechanical occlusion. Standard setup for intravital transillumination videomicroscopy and laser based imaging techniques were used for monitoring the blood clotting process. Temporal mechanical occlusion of blood vessels in the observed area was applied to ensure blood flow cessation. Subsequently, laser irradiation was used to induce vascular micro-injury. Changes in the vessel wall, as well as in the pattern of blood flow, predispose the area to vascular thrombosis, according to the paradigm of Virchow's triad. In our experiments, two elements of Virchow's triad were used to induce the process of clotting in vivo, and to assess it optically. We identified several parameters that can serve as markers of the blood clotting process in vivo. These include changes in light absorption in the area of illumination, as well as changes in the pattern of the red blood cells' micro-movement in the vessels where blood flow is completely arrested. Thus, our results indicate that blood coagulation status can be characterized by non-invasive, in vivo methodologies.
Kurasawa, Shintaro; Koyama, Shouhei; Ishizawa, Hiroaki; Fujimoto, Keisaku; Chino, Shun
2017-11-23
This paper describes and verifies a non-invasive blood glucose measurement method using a fiber Bragg grating (FBG) sensor system. The FBG sensor is installed on the radial artery, and the strain (pulse wave) that is propagated from the heartbeat is measured. The measured pulse wave signal was used as a collection of feature vectors for multivariate analysis aiming to determine the blood glucose level. The time axis of the pulse wave signal was normalized by two signal processing methods: the shortest-time-cut process and 1-s-normalization process. The measurement accuracy of the calculated blood glucose level was compared with the accuracy of these signal processing methods. It was impossible to calculate a blood glucose level exceeding 200 mg/dL in the calibration curve that was constructed by the shortest-time-cut process. In the 1-s-normalization process, the measurement accuracy of the blood glucose level was improved, and a blood glucose level exceeding 200 mg/dL could be calculated. By verifying the loading vector of each calibration curve to calculate the blood glucose level with a high measurement accuracy, we found the gradient of the peak of the pulse wave at the acceleration plethysmogram greatly affected.
Jordan, A; Chen, D; Yi, Q-L; Kanias, T; Gladwin, M T; Acker, J P
2016-07-01
Quality control (QC) data collected by blood services are used to monitor production and to ensure compliance with regulatory standards. We demonstrate how analysis of quality control data can be used to highlight the sources of variability within red cell concentrates (RCCs). We merged Canadian Blood Services QC data with manufacturing and donor records for 28 227 RCC between June 2011 and October 2014. Units were categorized based on processing method, bag manufacturer, donor age and donor sex, then assessed based on product characteristics: haemolysis and haemoglobin levels, unit volume, leucocyte count and haematocrit. Buffy-coat method (top/bottom)-processed units exhibited lower haemolysis than units processed using the whole-blood filtration method (top/top). Units from female donors exhibited lower haemolysis than male donations. Processing method influenced unit volume and the ratio of additive solution to residual plasma. Stored red blood cell characteristics are influenced by prestorage processing and donor factors. Understanding the relationship between processing, donors and RCC quality will help blood services to ensure the safety of transfused products. © 2016 International Society of Blood Transfusion.
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Huang, Yan-Jang S; Lyons, Amy C; Hsu, Wei-Wen; Park, So Lee; Higgs, Stephen; Vanlandingham, Dana L
2017-01-01
Infection of mosquitoes is an essential step for the transmission of mosquito-borne arboviruses in nature. Engorgement of infectious blood meals from viremic infected vertebrate hosts allows the entry of viruses and initiates infection of midgut epithelial cells. Historically, the infection process of arboviruses in mosquitoes has been studied through the engorgement of mosquitoes from viremic laboratory animals or from artificial feeders containing blood mixed with viruses harvested from cell cultures. The latter approach using so-called artificial blood meals is more frequently used since it is readily optimized to maximize viral titer, negates the use of animals and can be used with viruses for which there are no small animal models. Use of artificial blood meals has enabled numerous studies on mosquito infections with a wide variety of viruses; however, as described here, with suitable modification it can also be used to study the interplay between infection, specific blood components, and physiological consequences associated with blood engorgement. For hematophagous female mosquitoes, blood is the primary nutritional source supporting all physiological process including egg development, and also influences neurological processes and behaviors such as host-seeking. Interactions between these blood-driven vector biological processes and arbovirus infection that is mediated via blood engorgement have not yet been specifically studied. This is in part because presentation of virus in whole blood inevitably induces enzymatic digestion processes, hormone driven oogenesis, and other biological changes. In this study, the infection process of Zika virus (ZIKV) in Aedes aegypti was characterized by oral exposure via viral suspension meals within minimally bovine serum albumin complemented medium or within whole blood. The use of bovine serum albumin in infectious meals provides an opportunity to evaluate the role of serum albumin during the process of flavivirus infection in mosquitoes. Infectious whole blood meals and infectious bovine serum albumin meals containing ZIKV were orally presented to two different groups of Ae. aegypti through membrane feeding. At 7 and 14 days post infection, infectious viruses were detected and viral dissemination from gut to other mosquito tissues was analyzed in orally challenged mosquitoes with 50% tissue culture infectious dose method on Vero76 cells. Zika virus infection was significantly impaired among mosquitoes orally challenged with infectious protein meals as compared to infectious whole blood meals. These results indicate the importance of the blood meal in the infection process of arboviruses in mosquitoes. It provides the basis for future studies to identify critical components in the blood of vertebrate hosts that facilitate arbovirus infection in mosquitoes.
Voller, Stephannie Baehl; Chock, Susanne; Ernst, Linda M.; Su, Emily; Liu, Xin; Farrow, Kathryn N.; Mestan, Karen K.
2014-01-01
Background Preterm infants are at risk for postnatal growth failure (PGF). Identification of biomarkers that are associated with neonatal growth may help reduce PGF and associated long-term morbidity. Objective To investigate the associations between cord blood vascular endothelial growth factor (VEGF) and its soluble receptor (sFlt-1) with birth weight (BW) and postnatal growth in premature infants. Study Design and Methods From an ongoing birth cohort, 123 premature infants from 23 to 36 weeks gestational age (GA) were studied. Cord blood plasma VEGF and sFlt-1 were measured via enzyme-linked immunoassay. Growth parameters and nutritional information were evaluated. Multivariate logistic regression models were constructed to evaluate the associations of VEGF and sFlt-1 on PGF, defined as weight < 10th percentile at 36 weeks corrected age or discharge. Results VEGF was positively correlated, and sFlt-1 was negatively correlated with BW and BW-for-GA percentiles. Higher cord blood VEGF levels were associated with reduced risk of PGF (OR=0.7; 95% CI=0.5–0.9), while higher sFlt-1 levels appeared to increase the risk of PGF (OR=1.6; 95% CI=1.1–2.4). The above biomarker associations were attenuated after adjustment for maternal preeclampsia, fetal growth restriction and related neonatal characteristics, and when taking into account placental vascular pathologies. Longitudinal growth patterns by mean weight and length percentiles were consistently lower among infants with low VEGF/sFlt-1 ratios. Conclusions Our data support that intrauterine regulation of angiogenesis is an important mechanism of fetal and postnatal growth. Cord blood VEGF and sFlt-1 are useful in elucidating how intrauterine processes may have long-standing effects on developing premature infants. PMID:24480606
The taphonomy of blood components in decomposing bone and its relevance to physical anthropology.
Cappella, Annalisa; Bertoglio, Barbara; Castoldi, Elisa; Maderna, Emanuela; Di Giancamillo, Alessia; Domeneghini, Cinzia; Andreola, Salvatore; Cattaneo, Cristina
2015-12-01
The variation and persistence of blood components, in particular red blood cells (RBCs), within bone tissue during the decomposition process, especially at the early stages and in different taphonomic conditions, has never been thoroughly investigated, regardless of the fact that knowing how blood survives or degrades within bone could be of help in solving many anthropological issues, such as trauma analysis and interpretation. This research investigated the influence of time and taphonomy on the persistence and detectability of blood components in parietal bone fragments (of different post mortem periods and taphonomic conditions) through histological (Hematoxilin and Eosin, HE) and immunohistochemical (Glycophorin A, GYPA) analyses. The immunohistochemical investigation for GYPA showed the presence of RBCs under the form of erythrocyte debris or residues otherwise morphologically unidentifiable using only HE staining. Hence, while well-defined RBCs can be observed only in the first week of decomposition, afterward these structures can be detectable with certainty only by immunohistochemical analysis, which reveals discrete quantities of RBC residues also in dry bone (post mortem interval, or PMI, of 15 years), but not in archaeological samples, in which the greater PMI and the different taphonomic conditions together could be the answer behind such difference. This study highlights the usefulness and potential of immunohistochemical detection of GYPA in RBC investigation and gives a realistic idea of the persistence and detectability of erythrocytes in different osteological taphonomic conditions, in contrast to results reported by some authors in literature. Another important result concerns the detection of RBC residues in dry bone, which opens the way to the possible use of RBCs in trauma interpretation. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Durduran, Turgut; Yu, Guoqiang; Zhou, Chao; Lech, Gwen; Chance, Britton; Yodh, Arjun G.
2003-07-01
A hybrid instrument combining near infrared and diffuse correlation spectroscopies was used to measure muscle oxygenation and blood flow dynamics during cuff occlusion and ischemia. Measurements were done on six healthy subjects on their arm and leg flexor muscles. Hemodynamic response was characterized for blood oxygen saturation, total hemoglobin concenration and relative blood flow speed. The characterization allowed us to define the normal response range as well as showing the feasibility of using a hybrid instrument for dynamic measurements.
The need for defining- and redefining- hypertension: beyond the numbers.
Giles, Thomas D; Sander, Gary E
2005-12-01
By definition, hypertension has been linked to blood pressure levels. This link is demonstrated in the various iterations of reports by the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC). Over the past few decades, the definition of hypertension has changed with each new report, and so have the levels of blood pressure that are considered satisfactory after treatment. In this article, Drs Giles and Sander review the current definitions of hypertension in clinical practice and its evaluation in light of total cardiovascular risk.
The Metabolomic Profile of Umbilical Cord Blood in Neonatal Hypoxic Ischaemic Encephalopathy
Walsh, Brian H.; Broadhurst, David I.; Mandal, Rupasri; Wishart, David S.; Boylan, Geraldine B.; Kenny, Louise C.; Murray, Deirdre M.
2012-01-01
Background Hypoxic ischaemic encephalopathy (HIE) in newborns can cause significant long-term neurological disability. The insult is a complex injury characterised by energy failure and disruption of cellular homeostasis, leading to mitochondrial damage. The importance of individual metabolic pathways, and their interaction in the disease process is not fully understood. The aim of this study was to describe and quantify the metabolomic profile of umbilical cord blood samples in a carefully defined population of full-term infants with HIE. Methods and Findings The injury severity was defined using both the modified Sarnat score and continuous multichannel electroencephalogram. Using these classification systems, our population was divided into those with confirmed HIE (n = 31), asphyxiated infants without encephalopathy (n = 40) and matched controls (n = 71). All had umbilical cord blood drawn and biobanked at −80°C within 3 hours of delivery. A combined direct injection and LC-MS/MS assay (AbsolutIDQ p180 kit, Biocrates Life Sciences AG, Innsbruck, Austria) was used for the metabolomic analyses of the samples. Targeted metabolomic analysis showed a significant alteration between study groups in 29 metabolites from 3 distinct classes (Amino Acids, Acylcarnitines, and Glycerophospholipids). 9 of these metabolites were only significantly altered between neonates with Hypoxic ischaemic encephalopathy and matched controls, while 14 were significantly altered in both study groups. Multivariate Discriminant Analysis models developed showed clear multifactorial metabolite associations with both asphyxia and HIE. A logistic regression model using 5 metabolites clearly delineates severity of asphyxia and classifies HIE infants with AUC = 0.92. These data describe wide-spread disruption to not only energy pathways, but also nitrogen and lipid metabolism in both asphyxia and HIE. Conclusion This study shows that a multi-platform targeted approach to metabolomic analyses using accurately phenotyped and meticulously biobanked samples provides insight into the pathogenesis of perinatal asphyxia. It highlights the potential for metabolomic technology to develop a diagnostic test for HIE. PMID:23227182
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... sufficient to insure optimal cell preservation shall be left with the red cells except when a cryoprotective...
Lenk, Gabriel; Sandkvist, Sören; Pohanka, Anton; Stemme, Göran; Beck, Olof; Roxhed, Niclas
2015-01-01
DBS samples collected from a fingerprick typically vary in volume and homogeneity and hence make an accurate quantitative analysis of DBS samples difficult. We report a prototype which first defines a precise liquid volume and subsequently stores it to a conventional DBS matrix. Liquid volumes of 2.2 µl ± 7.1% (n = 21) for deionized water and 6.1 µl ± 8.8% (n = 15) for whole blood have been successfully metered and stored in DBS paper. The new method of collecting a defined volume of blood by DBS sampling has the potential to reduce assay bias for the quantitative evaluation of DBS samples while maintaining the simplicity of conventional DBS sampling.
... After What Happens to Donated Blood First Time Blood Donors Hosting a Blood Drive Manage My Blood Drive ... some information about donating blood. Tip: Download the Blood Donor app . After your first donation, use the digital ...
Hypertension, type 2 diabetes, and blood groups in a population of African ancestry.
Nemesure, Barbara; Wu, Suh-Yuh; Hennis, Anselm; Leske, M Cristina
2006-01-01
To evaluate the possible relationship of hypertension and diabetes with the ABO, Rhesus, and Duffy blood groups, which are known markers of African ancestry. Population-based study. A random sample of 1253 Barbados residents, > or = 40 years of age. Hypertension was defined as a systolic blood pressure >140 mm Hg or a diastolic blood pressure >90 mm Hg or use of antihypertensive treatment; type 2 diabetes was defined as a glycosylated hemoglobin level >10% and/or a history of treatment in those >30 years of age. In logistic regression analyses, elevated diastolic blood pressure was positively associated with years of age (odds ratio [OR] 1.03, 95% confidence interval CI 1.02-1.05), the Rhesus D+ antigen (OR 2.68, 95% CI 1.21-5.97) and body mass index (OR 1.53, 95% CI 1.19-1.96), but negatively associated with the ABO blood group A allele (OR 0.68, 95% CI .48-.97). A separate logistic regression model indicated that the likelihood of diabetes increased with years of age (OR 1.03, 95% CI 1.01-1.04), hypertension (OR 1.56, 95% CI 1.10-2.20), body mass index (OR 1.68, 95% CI 1.29-2.20), and waist-hip ratio (OR 1.36, 95% CI 1.05-1.75), but decreased with presence of the Rhesus C+ antigen (OR .66, 95% CI .44-.97). The associations of diabetes and hypertension to these blood groups support possible genetic influences on both conditions in this and similar African-origin populations; however, further investigations in other settings are necessary to more fully elucidate these findings.
Biological variation of vitamins in blood of healthy individuals.
Talwar, Dinesh K; Azharuddin, Mohammed K; Williamson, Cathy; Teoh, Yee Ping; McMillan, Donald C; St J O'Reilly, Denis
2005-11-01
Components of biological variation can be used to define objective quality specifications (imprecision, bias, and total error), to assess the usefulness of reference values [index of individuality (II)], and to evaluate significance of changes in serial results from an individual [reference change value (RCV)]. However, biological variation data on vitamins in blood are limited. The aims of the present study were to determine the intra- and interindividual biological variation of vitamins A, E, B(1), B(2), B(6), C, and K and carotenoids in plasma, whole blood, or erythrocytes from apparently healthy persons and to define quality specifications for vitamin measurements based on their biology. Fasting plasma, whole blood, and erythrocytes were collected from 14 healthy volunteers at regular weekly intervals over 22 weeks. Vitamins were measured by HPLC. From the data generated, the intra- (CV(I)) and interindividual (CV(G)) biological CVs were estimated for each vitamin. Derived quality specifications, II, and RCV were calculated from CV(I) and CV(G). CV(I) was 4.8%-38% and CV(G) was 10%-65% for the vitamins measured. The CV(I)s for vitamins A, E, B(1), and B(2) were lower (4.8%-7.6%) than for the other vitamins in blood. For all vitamins, CV(G) was higher than CV(I), with II <1.0 (range, 0.36-0.95). The RCVs for vitamins were high (15.8%-108%). Apart from vitamins A, B(1), and erythrocyte B(2), the imprecision of our methods for measurement of vitamins in blood was within the desirable goal. For most vitamin measurements in plasma, whole blood, or erythrocytes, the desirable imprecision goals based on biological variation are obtainable by current methodologies. Population reference intervals for vitamins are of limited value in demonstrating deficiency or excess.
Lahoz-Beneytez, Julio; Elemans, Marjet; Zhang, Yan; Ahmed, Raya; Salam, Arafa; Block, Michael; Niederalt, Christoph; Asquith, Becca; Macallan, Derek
2016-06-30
Human neutrophils have traditionally been thought to have a short half-life in blood; estimates vary from 4 to 18 hours. This dogma was recently challenged by stable isotope labeling studies with heavy water, which yielded estimates in excess of 3 days. To investigate this disparity, we generated new stable isotope labeling data in healthy adult subjects using both heavy water (n = 4) and deuterium-labeled glucose (n = 9), a compound with more rapid labeling kinetics. To interpret results, we developed a novel mechanistic model and applied it to previously published (n = 5) and newly generated data. We initially constrained the ratio of the blood neutrophil pool to the marrow precursor pool (ratio = 0.26; from published values). Analysis of heavy water data sets yielded turnover rates consistent with a short blood half-life, but parameters, particularly marrow transit time, were poorly defined. Analysis of glucose-labeling data yielded more precise estimates of half-life (0.79 ± 0.25 days; 19 hours) and marrow transit time (5.80 ± 0.42 days). Substitution of this marrow transit time in the heavy water analysis gave a better-defined blood half-life of 0.77 ± 0.14 days (18.5 hours), close to glucose-derived values. Allowing the ratio of blood neutrophils to mitotic neutrophil precursors (R) to vary yielded a best-fit value of 0.19. Reanalysis of the previously published model and data also revealed the origin of their long estimates for neutrophil half-life: an implicit assumption that R is very large, which is physiologically untenable. We conclude that stable isotope labeling in healthy humans is consistent with a blood neutrophil half-life of less than 1 day. © 2016 by The American Society of Hematology.
Jamiolkowski, Megan A.; Pedersen, Drake D.; Wu, Wei-Tao; Antaki, James F.; Wagner, William R.
2016-01-01
The blood flow pathway within a device, together with the biomaterial surfaces and status of the patient’s blood, are well-recognized factors in the development of thrombotic deposition and subsequent embolization. Blood flow patterns are of particular concern for devices such as blood pumps (i.e. ventricular assist devices, VADs) where shearing forces can be high, volumes are relatively large, and the flow fields can be complex. However, few studies have examined the effect of geometric irregularities on thrombus formation on clinically relevant opaque materials under flow. The objective of this study was to quantify human platelet deposition onto Ti6Al4V alloys, as well as positive and negative control surfaces, in the region of defined crevices (~50–150 µm in width) that might be encountered in many VADs or other cardiovascular devices. To achieve this, reconstituted fresh human blood with hemoglobin-depleted red blood cells (to achieve optical clarity while maintaining relevant rheology), long working optics, and a custom designed parallel plate flow chamber were employed. The results showed that the least amount of platelet deposition occurred in the largest crevice size examined, which was counterintuitive. The greatest levels of deposition occurred in the 90 µm and 53 µm crevices at the lower wall shear rate. The results suggest that while crevices may be unavoidable in device manufacturing, the crevice size might be tailored, depending on the flow conditions, to reduce the risk of thromboembolic events. Further, these data might be used to improve the accuracy of predictive models of thrombotic deposition in cardiovascular devices to help optimize the blood flow path and reduce device thrombogenicity. PMID:27156141
Muñoz, Leticia; Albillos, Agustín; Nieto, Mónica; Reyes, Eduardo; Lledó, Lourdes; Monserrat, Jorge; Sanz, Eva; de la Hera, Antonio; Alvarez-Mon, Melchor
2005-08-01
A systemic inflammatory state with increased circulating tumor necrosis factor alpha (TNF-alpha) has been related to the bacterial infection susceptibility and hemodynamic derangement of patients with cirrhosis. We compared the activation status of immune cell subpopulations defined by 4-color cytometry in mesenteric and peripheral lymph nodes and blood of rats with CCl(4)-cirrhosis to define the immune response initiation site, the T-cell and monocyte contribution to pro-inflammatory cytokine production, as well as the pathogenic role of enteric bacteria in the cirrhosis immune response. Th1 cells and monocytes were expanded in the mesenteric nodes (P < .001) and blood (P < .001) of rats with cirrhosis, and activated to produce interferon gamma (P < .0001) and TNF-alpha (P < .0001), respectively. The greater numbers of recently activated CD134(+) Th cells in mesenteric nodes compared with blood, the correlation between their numbers in mesenteric nodes and blood (r = 0.66, P < .001), and the expansion of activated CD45RC(-) Th cells, which are unable to re-enter lymph nodes, in mesenteric nodes but not in blood or axillary nodes points to mesenteric nodes as the origin site of activated Th cells. Abrogation of bacterial translocation by bowel decontamination reduced the number of activated Th cells and monocytes, and normalized interferon gamma production by Th cells and TNF-alpha production by monocytes in mesenteric nodes and blood, respectively. In conclusion, in cirrhosis, enteric bacteria start off an orchestrated immune response cascade in mesenteric nodes involving Th1 polarization and monocyte activation to TNF-alpha production. Later, the recirculation of these activated effector immune cells into blood promotes systemic inflammation.
Shah, Ami P; Cobb, Benjamin T; Lower, Darla R; Shaikh, Nader; Rasmussen, Jayne; Hoberman, Alejandro; Wald, Ellen R; Rosendorff, Adam; Hickey, Robert W
2014-03-01
Urinary tract infections (UTI) are the most common serious bacterial infection in febrile infants. Urinalysis (UA) is a screening test for preliminary diagnosis of UTI. UA can be performed manually or using automated techniques. We sought to compare manual versus automated UA for urine specimens obtained via catheterization in the pediatric emergency department. In this prospective study, we processed catheterized urine samples from infants with suspected UTI by both the manual method (enhanced UA) and the automated method. We defined a positive enhanced UA as ≥ 10 white blood cells per cubic millimeter and presence of any bacteria per 10 oil immersion fields on a Gram-stained smear. We defined a positive automated UA as ≥ 2 white blood cells per high-powered field and presence of any bacteria using the IRIS iQ200 ELITE. We defined a positive urine culture as growth of ≥ 50,000 colony-forming units per milliliter of a single uropathogen. We analyzed data using SPSS software. A total of 703 specimens were analyzed. Prevalence of UTI was 7%. For pyuria, the sensitivity and positive predictive value (PPV) of the enhanced UA in predicting positive urine culture were 83.6% and 52.5%, respectively; corresponding values for the automated UA were 79.5% and 37.5%, respectively. For bacteriuria, the sensitivity and PPV of a Gram-stained smear (enhanced UA) were 83.6% and 59.4%, respectively; corresponding values for the automated UA were 73.4%, and 26.2%, respectively. Using criteria of both pyuria and bacteriuria for the enhanced UA resulted in a sensitivity of 77.5% and a PPV of 84.4%; corresponding values for the automated UA were 63.2% and 51.6%, respectively. Combining automated pyuria (≥ 2 white blood cells/high-powered microscopic field) with a Gram-stained smear resulted in a sensitivity of 75.5% and a PPV of 84%. Automated UA is comparable with manual UA for detection of pyuria in young children with suspected UTI. Bacteriuria detected by automated UA is less sensitive and specific for UTI when compared with a Gram-stained smear. We recommend using either manual or automated measurement of pyuria in combination with Gram-stained smear as the preferred technique for UA of catheterized specimens obtained from children in an acute care setting.
Job strain and ambulatory work blood pressure in healthy young men and women.
Light, K C; Turner, J R; Hinderliter, A L
1992-08-01
The effect of high job strain (defined as high psychological demands plus low decision latitude at work) on blood pressure was determined in 129 healthy, nonhypertensive men (n = 65) and women (n = 64). Blood pressure measures included mean screening levels obtained in a clinical environment, mean ambulatory levels from one 8-hour workday, and the change in levels from screening to mean work levels. In male workers, men with high and low job strain showed similar blood pressures at screening, but men with high job strain showed greater increases from screening to work, resulting in higher mean work blood pressure. Occupational status was unrelated to job strain or blood pressure in men. In female workers, women with high and low job strain did not differ in any measure of blood pressure; however, there were trends for higher occupational status and greater skill discretion to be associated with higher blood pressure responses at work in women.
The Blood Compatibilities of Blood Purification Membranes and Other Materials Developed in Japan
Abe, Takaya; Kato, Karen; Fujioka, Tomoaki; Akizawa, Tadao
2011-01-01
The biocompatibilities in blood purification therapy are defined as “a concept to stipulate safety of blood purification therapy by an index based on interaction in the body arising from blood purification therapy itself.” The biocompatibilities are associated with not only materials to be used but also many factors such as sterilization method and eluted substance. It is often evaluated based on impacts on cellular pathways and on humoral pathways. Since the biocompatibilities of blood purification therapy in particular hemodialysis are not just a prognostic factor for dialysis patients but a contributory factor for long-term complications, it should be considered with adequate attention. It is important that blood purification therapy should be performed by consistently evaluating not only risks associated with these biocompatibilities but also the other advantages obtained from treatments. In this paper, the biocompatibilities of membrane and adsorption material based on Japanese original which are used for blood purification therapy are described. PMID:21969830
Karvounis, E C; Exarchos, T P; Fotiou, E; Sakellarios, A I; Iliopoulou, D; Koutsouris, D; Fotiadis, D I
2013-01-01
With an ever increasing number of biological models available on the internet, a standardized modelling framework is required to allow information to be accessed and visualized. In this paper we propose a novel Extensible Markup Language (XML) based format called ART-ML that aims at supporting the interoperability and the reuse of models of geometry, blood flow, plaque progression and stent modelling, exported by any cardiovascular disease modelling software. ART-ML has been developed and tested using ARTool. ARTool is a platform for the automatic processing of various image modalities of coronary and carotid arteries. The images and their content are fused to develop morphological models of the arteries in 3D representations. All the above described procedures integrate disparate data formats, protocols and tools. ART-ML proposes a representation way, expanding ARTool, for interpretability of the individual resources, creating a standard unified model for the description of data and, consequently, a format for their exchange and representation that is machine independent. More specifically, ARTool platform incorporates efficient algorithms which are able to perform blood flow simulations and atherosclerotic plaque evolution modelling. Integration of data layers between different modules within ARTool are based upon the interchange of information included in the ART-ML model repository. ART-ML provides a markup representation that enables the representation and management of embedded models within the cardiovascular disease modelling platform, the storage and interchange of well-defined information. The corresponding ART-ML model incorporates all relevant information regarding geometry, blood flow, plaque progression and stent modelling procedures. All created models are stored in a model repository database which is accessible to the research community using efficient web interfaces, enabling the interoperability of any cardiovascular disease modelling software models. ART-ML can be used as a reference ML model in multiscale simulations of plaque formation and progression, incorporating all scales of the biological processes.
Downey, Charlene M; Singla, Arvind K; Villemaire, Michelle L; Buie, Helen R; Boyd, Steven K; Jirik, Frank R
2012-01-01
Techniques for visualizing and quantifying the microvasculature of tumors are essential not only for studying angiogenic processes but also for monitoring the effects of anti-angiogenic treatments. Given the relatively limited information that can be gleaned from conventional 2-D histological analyses, there has been considerable interest in methods that enable the 3-D assessment of the vasculature. To this end, we employed a polymerizing intravascular contrast medium (Microfil) and micro-computed tomography (micro-CT) in combination with a maximal spheres direct 3-D analysis method to visualize and quantify ex-vivo vessel structural features, and to define regions of hypoperfusion within tumors that would be indicative of necrosis. Employing these techniques we quantified the effects of a vascular disrupting agent on the tumor vasculature. The methods described herein for quantifying whole tumor vascularity represent a significant advance in the 3-D study of tumor angiogenesis and evaluation of novel therapeutics, and will also find potential application in other fields where quantification of blood vessel structure and necrosis are important outcome parameters.
Arieli, Ran
2015-01-15
All air breathing vertebrates are endowed with pulmonary surfactants, surface-active lipoprotein complexes formed by type II alveolar cells. Surfactants are deposited in clearly defined areas on the luminal aspect of blood vessels, producing hydrophobic spots. Gas nanobubbles measuring 5-100nm form spontaneously on the smooth hydrophobic spot from dissolved gas. Bubbles nucleate and grow at these spots after decompression from high pressure. Proteins with hydrophobic regions circulating in the blood will adhere to the gas phase-plasma interface. Deformation of their secondary and tertiary configuration will present them as foreign molecules or autoantigens. Components of the intact protein which are also present in a deformed protein may be recognized as foreign too. This process is proposed as the trigger for autoimmune diseases. The presence of autoimmune disease in air breathing vertebrates, increased autoimmunity and the elevated risk of decompression sickness with age, as well as variable sensitivity to both diseases, can be matched with the appearance of surfactant spots. Eliminating these spots may provide protection against both diseases. Copyright © 2014 Elsevier B.V. All rights reserved.
Polypill: Progress and Challenges to Global Use--Update on the Trials and Policy Implementation.
Webster, Ruth; Rodgers, Anthony
2015-12-01
Cardiovascular disease (CVD) is the leading cause of mortality globally. Most people with cardiovascular disease do not take long-term cholesterol-lowering, anti-platelet and blood pressure-lowering medications despite proven benefits. Fixed-dose combination pills ('polypills') have been shown to improve adherence to these recommended medications with corresponding improvements in risk factors such as blood pressure and low-density lipoprotein (LDL) cholesterol. Among patients not taking the full complement of recommended CVD preventive therapies, use of a polypill-based strategy (i.e. initiating treatment with single-pill combination medication then titrating further therapy as needed) has large potential benefits in reducing global morbidity and mortality. Despite this, few polypills are available on the market due to market failure in the funding of research and development for affordable non-communicable disease medicines. Additionally, defining a path to market has been problematic in that fixed-dose combinations with multiple different drug classes included are quite novel, and regulatory processes to review these types of applications are not well established. Despite these delays, progress is slowly being made.
Nutritional update for physicians: plant-based diets.
Tuso, Philip J; Ismail, Mohamed H; Ha, Benjamin P; Bartolotto, Carole
2013-01-01
The objective of this article is to present to physicians an update on plant-based diets. Concerns about the rising cost of health care are being voiced nationwide, even as unhealthy lifestyles are contributing to the spread of obesity, diabetes, and cardiovascular disease. For these reasons, physicians looking for cost-effective interventions to improve health outcomes are becoming more involved in helping their patients adopt healthier lifestyles. Healthy eating may be best achieved with a plant-based diet, which we define as a regimen that encourages whole, plant-based foods and discourages meats, dairy products, and eggs as well as all refined and processed foods. We present a case study as an example of the potential health benefits of such a diet. Research shows that plant-based diets are cost-effective, low-risk interventions that may lower body mass index, blood pressure, HbA1C, and cholesterol levels. They may also reduce the number of medications needed to treat chronic diseases and lower ischemic heart disease mortality rates. Physicians should consider recommending a plant-based diet to all their patients, especially those with high blood pressure, diabetes, cardiovascular disease, or obesity.
Threshold Switchable Particles (TSPs) To Control Internal Hemorrhage
2016-09-01
hemorrhage at local sites. Four collaborating laboratories worked together under this contract to define threshold levels of activators of blood clotting...such that the candidate clotting activators will circulate in the blood at a concentration below the threshold necessary to trigger clotting, but...accumulation of the activators at sites of internal injury/bleeding will cause the local concentration of clotting activators to exceed the clotting
Hitchhiker's guide to the red cell storage galaxy: Omics technologies and the quality issue.
D'Alessandro, Angelo; Seghatchian, Jerard
2017-04-01
Red blood cell storage in the blood bank makes millions of units of available for transfusion to civilian and military recipients every year. From glass bottles to plastic bags, from anticoagulants to complex additives, from whole blood to leukocyte filtered packed red blood cells: huge strides have been made in the field of blood component processing and storage in the blood bank during the last century. Still, refrigerated preservation of packed red blood cells under blood bank conditions results in the progressive accumulation of a wide series of biochemical and morphological changes to the stored erythrocytes, collectively referred to as the storage lesion(s). Approximately ten years ago, retrospective clinical evidence had suggested that such lesion(s) may be clinically relevant and mediate some of the untoward transfusion-related effects observed especially in some categories of recipients at risk (e.g. massively or chronically transfused recipients). Since then, randomized clinical trials have failed to prospectively detect any signal related to red cell storage duration and increased morbidity and mortality in several categories of recipients, at the limits of the statistical power of these studies. While a good part of the transfusion community has immediately adopted the take-home message "if it isn't broken, don't fix it" (i.e. no change to the standard of practice should be pursued), decision makers have been further questioning whether there may be room for further improvements in this field. Provocatively, we argue that consensus has yet to be unanimously reached on what makes a good quality marker of the red cell storage lesion and transfusion safety/efficacy. In other words, if it is true that "you can't manage what you can't measure", then future advancements in the field of transfusion medicine will necessarily rely on state of the art analytical omics technologies of well-defined quality parameters. Heavily borrowing from Douglas Adam's imaginary repertoire from the world famous "Hitchhiker's guide to the galaxy", we briefly summarize how some of the principles for intergalactic hitchhikers may indeed apply to inform navigation through the complex universe of red cell storage quality, safety and efficacy. Copyright © 2017 Elsevier Ltd. All rights reserved.
Burgess, L Goodwin; Goyal, Nitin; Jones, G Morgan; Khorchid, Yasser; Kerro, Ali; Chapple, Kristina; Tsivgoulis, Georgios; Alexandrov, Andrei V; Chang, Jason J
2018-04-13
We sought to assess the risk of acute kidney injury (AKI) and mortality associated with intensive systolic blood pressure reduction in acute intracerebral hemorrhage. Patients with acute intracerebral hemorrhage had spontaneous cause and symptom onset within 24 hours. We excluded patients with structural causes, coagulopathy, thrombocytopenia, and preexisting end-stage renal disease. We defined AKI using the Acute Kidney Injury Network criteria. Chronic kidney disease status was included in risk stratification and was defined by Kidney Disease Outcomes Quality Initiative staging. Maximum systolic blood pressure reduction was defined over a 12-hour period and dichotomized using receiver operating characteristic curve analysis. Descriptive statistics were done using independent sample t tests, χ 2 tests, and Mann-Whitney U tests, whereas multivariable logistic regression analysis was used to evaluate for predictors for AKI and mortality. A total of 448 patients with intracerebral hemorrhage met inclusion criteria. Maximum systolic blood pressure reduction was dichotomized to 90 mm Hg and found to increase the risk of AKI in patients with normal renal function (odds ratio, 2.1; 95% confidence interval, 1.19-3.62; P =0.010) and chronic kidney disease (odds ratio, 3.91; 95% confidence interval, 1.26-12.15; P =0.019). The risk of AKI was not significantly different in normal renal function versus chronic kidney disease groups when adjusted for demographics, presentation characteristics, and medications associated with AKI. AKI positively predicted mortality for patients with normal renal function (odds ratio, 2.41; 95% confidence interval, 1.11-5.22; P =0.026) but not for patients with chronic kidney disease (odds ratio, 3.13; 95% confidence interval, 0.65-15.01; P =0.154). These results indicate that intensive systolic blood pressure reduction with a threshold >90 mm Hg in patients with acute intracerebral hemorrhage may be an independent predictor for AKI. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Microfluidic Blood Cell Preparation: Now and Beyond
Yu, Zeta Tak For; Yong, Koh Meng Aw; Fu, Jianping
2014-01-01
Blood plays an important role in homeostatic regulation with each of its cellular components having important therapeutic and diagnostic uses. Therefore, separation and sorting of blood cells has been of a great interest to clinicians and researchers. However, while conventional methods of processing blood have been successful in generating relatively pure fractions, they are time consuming, labor intensive, and are not optimal for processing small volume blood samples. In recent years, microfluidics has garnered great interest from clinicians and researchers as a powerful technology for separating blood into different cell fractions. As microfluidics involves fluid manipulation at the microscale level, it has the potential for achieving high-resolution separation and sorting of blood cells down to a single-cell level, with an added benefit of integrating physical and biological methods for blood cell separation and analysis on the same single chip platform. This paper will first review the conventional methods of processing and sorting blood cells, followed by a discussion on how microfluidics is emerging as an efficient tool to rapidly change the field of blood cell sorting for blood-based therapeutic and diagnostic applications. PMID:24515899
Hyperglycemia in bacterial meningitis: a prospective cohort study
2009-01-01
Background Hyperglycemia has been associated with unfavorable outcome in several disorders, but few data are available in bacterial meningitis. We assessed the incidence and significance of hyperglycemia in adults with bacterial meningitis. Methods We collected data prospectively between October 1998 and April 2002, on 696 episodes of community-acquired bacterial meningitis, confirmed by culture of CSF in patients >16 years. Patients were dichotomized according to blood glucose level on admission. A cutoff random non-fasting blood glucose level of 7.8 mmol/L (140 mg/dL) was used to define hyperglycemia, and a cutoff random non-fasting blood glucose level of 11.1 mmol/L (200 mg/dL) was used to define severe hyperglycemia. Unfavorable outcome was defined on the Glasgow outcome scale as a score <5. We also evaluated characteristics of patients with a preadmission diagnosis of diabetes mellitus. Results 69% of patients were hyperglycemic and 25% severely hyperglycemic on admission. Compared with non-hyperglycemic patients, hyperglycemia was related with advanced age (median, 55 yrs vs. 44 yrs, P < 0.0001), preadmission diagnosis of diabetes (9% vs. 3%, P = 0.005), and distant focus of infection (37% vs. 28%, P = 0.02). They were more often admitted in coma (16% vs. 8%; P = 0.004) and with pneumococcal meningitis (55% vs. 42%, P = 0.007). These differences remained significant after exclusion of patients with known diabetes. Hyperglycemia was related with unfavorable outcome in a univariate analysis but this relation did not remain robust in a multivariate analysis. Factors predictive for neurologic compromise were related with higher blood glucose levels, whereas factors predictive for systemic compromise were related with lower blood glucose levels. Only a minority of severely hyperglycemic patients were known diabetics (19%). The vast majority of these known diabetic patients had meningitis due to Streptococcus pneumoniae (67%) or Listeria monocytogenes (13%) and they were at high risk for unfavorable outcome (52%). Conclusion The majority of patients with bacterial meningitis have hyperglycemic blood glucose levels on admission. Hyperglycemia can be explained by a physical stress reaction, the central nervous system insult leading to disturbed blood-glucose regulation mechanisms, and preponderance of diabetics for pneumococcal meningitis. Patients with diabetes and bacterial meningitis are at high risk for unfavorable outcome. PMID:19426501
Control of blood pressure in Scotland: the rule of halves.
Smith, W C; Lee, A J; Crombie, I K; Tunstall-Pedoe, H
1990-04-14
Audit of detection, treatment, and control of hypertension in adults in Scotland. Cross sectional survey with random population sampling. General practice centres in 22 Scottish districts. 5123 Men and 5236 women aged 40-59 in the Scottish heart health study, randomly selected from 22 districts throughout Scotland, of whom 1262 men and 1061 women had hypertension (defined as receiving antihypertensive treatment or with blood pressure above defined cut off points). Hypertension (assessed by standardised recording, questionnaire on diagnosis, and antihypertensive drug treatment) according to criteria of the World Health Organisation (receiving antihypertensive treatment or blood pressure greater than or equal to 160/95 mm Hg, or both) and to modified criteria of the British Hypertension Society. In half the men with blood pressure greater than or equal to 160/95 mm Hg hypertension was undetected (670/1262, 53%), in half of those in whom it had been detected it was untreated (250/592, 42%), and in half of those receiving treatment it was not controlled (172/342, 50%). In women the numbers were: 486/1061, 46%; 188/575, 33%; and 155/387, 40% respectively. Assessment of blood pressure according to the British Hypertension Society's recommendations showed an improvement, but in only a quarter of men and 42% of women was hypertension detected and treated satisfactorily (142/561, 215/514 respectively). The detection and control of hypertension in Scotland is unsatisfactory, affecting management of this and other conditions, such as high blood cholesterol concentration, whose measurement is opportunistic and selective and depends on recognition of other risk factors.
O'Sullivan, J M; McCready, V R; Flux, G; Norman, A R; Buffa, F M; Chittenden, S; Guy, M; Pomeroy, K; Cook, G; Gadd, J; Treleaven, J; Al-Deen, A; Horwich, A; Huddart, R A; Dearnaley, D P
2002-01-01
We tested the feasibility and toxicity of high activities Rhenium-186 hydroxyethylidene diphosphonate, with peripheral blood stem cell rescue in patients with progressive hormone refractory prostate cancer metastatic to bone. Twenty-five patients received between 2500 and 5000 MBq of Rhenium-186 hydroxyethylidene diphosphonate followed 14 days later by the return of peripheral blood peripheral blood stem cells. Activity limiting toxicity was defined as grade III haematological toxicity, lasting at least 7 days, or grade IV haematological toxicity of any duration or any serious unexpected toxicity. Activity limiting toxicity occurred in two of six who received activities of 5000 MBq and maximum tolerated activity was defined at this activity level. Prostate specific antigen reductions of 50% or more lasting at least 4 weeks were seen in five of the 25 patients (20%) all of whom received more than 3500 MBq of Rhenium-186 hydroxyethylidene diphosphonate. The actuarial survival at 1 year is 54%. Administered activities of 5000 MBq of Rhenium-186 hydroxyethylidene diphosphonate are feasible using autologous peripheral blood peripheral blood stem cell rescue in patients with progressive hormone refractory prostate cancer metastatic to bone. The main toxicity is thrombocytopaenia, which is short lasting. A statistically significant activity/prostate specific antigen response was seen. We have now commenced a Phase II trial to further evaluate response rates. British Journal of Cancer (2002) 86, 1715–1720. doi:10.1038/sj.bjc.6600348 www.bjcancer.com © 2002 Cancer Research UK PMID:12087455
A RAPID Method for Blood Processing to Increase the Yield of Plasma Peptide Levels in Human Blood.
Teuffel, Pauline; Goebel-Stengel, Miriam; Hofmann, Tobias; Prinz, Philip; Scharner, Sophie; Körner, Jan L; Grötzinger, Carsten; Rose, Matthias; Klapp, Burghard F; Stengel, Andreas
2016-04-28
Research in the field of food intake regulation is gaining importance. This often includes the measurement of peptides regulating food intake. For the correct determination of a peptide's concentration, it should be stable during blood processing. However, this is not the case for several peptides which are quickly degraded by endogenous peptidases. Recently, we developed a blood processing method employing Reduced temperatures, Acidification, Protease inhibition, Isotopic exogenous controls and Dilution (RAPID) for the use in rats. Here, we have established this technique for the use in humans and investigated recovery, molecular form and circulating concentration of food intake regulatory hormones. The RAPID method significantly improved the recovery for (125)I-labeled somatostatin-28 (+39%), glucagon-like peptide-1 (+35%), acyl ghrelin and glucagon (+32%), insulin and kisspeptin (+29%), nesfatin-1 (+28%), leptin (+21%) and peptide YY3-36 (+19%) compared to standard processing (EDTA blood on ice, p <0.001). High performance liquid chromatography showed the elution of endogenous acyl ghrelin at the expected position after RAPID processing, while after standard processing 62% of acyl ghrelin were degraded resulting in an earlier peak likely representing desacyl ghrelin. After RAPID processing the acyl/desacyl ghrelin ratio in blood of normal weight subjects was 1:3 compared to 1:23 following standard processing (p = 0.03). Also endogenous kisspeptin levels were higher after RAPID compared to standard processing (+99%, p = 0.02). The RAPID blood processing method can be used in humans, yields higher peptide levels and allows for assessment of the correct molecular form.
Rabe, Fran; Kadidlo, Diane; Van Orsow, Lisa; McKenna, David
2013-10-01
Qualification of a cord blood bank (CBB) is a complex process that includes evaluation of multiple aspects of donor screening and testing, processing, accreditation and approval by professional cell therapy groups, and results of received cord blood units. The University of Minnesota Medical Center Cell Therapy Laboratory has established a CBB vendor qualification process to ensure the CBB meets established regulatory and quality requirements. The deployed qualification of CBBs is based on retrospective and prospective review of the CBB. Forty-one CBBs were evaluated retrospectively: seven CBBs were disqualified based on failed quality control (QC) results. Eight CBBs did not meet the criteria for retrospective qualification because fewer than 3 cord blood units were received and the CBB was not accredited. As of March 2012, three US and one non-US CBBs have been qualified prospectively. One CBB withdrew from the qualification process after successful completion of the comprehensive survey and subsequent failure of the provided QC unit to pass the minimum criteria. One CBB failed the prospective qualification process based on processing methods that were revealed during the paper portion of the evaluation. A CBB qualification process is necessary for a transplant center to manage the qualification of the large number of CBBs needed to support a umbilical cord blood transplantation program. A transplant center that has utilized cord blood for a number of years before implementation of a qualification process should use a retrospective qualification process along with a prospective process. © 2013 American Association of Blood Banks.
Engle, Martha; Ferguson, Allison; Fields, Willa
2016-01-01
The purpose of this quality improvement project was to redesign a hospital meal delivery process in order to shorten the time between blood glucose monitoring and corresponding insulin administration and improve glycemic control. This process change redesigned the workflow of the dietary and nursing departments. Modifications included nursing, rather than dietary, delivering meal trays to patients receiving insulin. Dietary marked the appropriate meal trays and phoned each unit prior to arrival on the unit. The process change was trialed on 2 acute care units prior to implementation hospital wide. Elapsed time between blood glucose monitoring and insulin administration was analyzed before and after process change as well as evaluation of glucometrics: percentage of patients with blood glucose between 70 and 180 mg/dL (percent perfect), blood glucose greater than 300 mg/dL (extreme hyperglycemia), and blood glucose less than 70 mg/dL (hypoglycemia). Percent perfect glucose results improved from 45% to 53%, extreme hyperglycemia (blood glucose >300 mg/dL) fell from 11.7% to 5%. Hypoglycemia demonstrated a downward trend line, demonstrating that with improving glycemic control hypoglycemia rates did not increase. Percentage of patients receiving meal insulin within 30 minutes of blood glucose check increased from 35% to 73%. In the hospital, numerous obstacles were present that interfered with on-time meal insulin delivery. Establishing a meal delivery process with the nurse performing the premeal blood glucose check, delivering the meal, and administering the insulin improves overall blood glucose control. Nurse-led process improvement of blood glucose monitoring, meal tray delivery, and insulin administration does lead to improved glycemic control for the inpatient population.
Neonatal Glycemia and Neurodevelopmental Outcomes at 2 Years.
McKinlay, Christopher J D; Alsweiler, Jane M; Ansell, Judith M; Anstice, Nicola S; Chase, J Geoffrey; Gamble, Gregory D; Harris, Deborah L; Jacobs, Robert J; Jiang, Yannan; Paudel, Nabin; Signal, Matthew; Thompson, Benjamin; Wouldes, Trecia A; Yu, Tzu-Ying; Harding, Jane E
2015-10-15
Neonatal hypoglycemia is common and can cause neurologic impairment, but evidence supporting thresholds for intervention is limited. We performed a prospective cohort study involving 528 neonates with a gestational age of at least 35 weeks who were considered to be at risk for hypoglycemia; all were treated to maintain a blood glucose concentration of at least 47 mg per deciliter (2.6 mmol per liter). We intermittently measured blood glucose for up to 7 days. We continuously monitored interstitial glucose concentrations, which were masked to clinical staff. Assessment at 2 years included Bayley Scales of Infant Development III and tests of executive and visual function. Of 614 children, 528 were eligible, and 404 (77% of eligible children) were assessed; 216 children (53%) had neonatal hypoglycemia (blood glucose concentration, <47 mg per deciliter). Hypoglycemia, when treated to maintain a blood glucose concentration of at least 47 mg per deciliter, was not associated with an increased risk of the primary outcomes of neurosensory impairment (risk ratio, 0.95; 95% confidence interval [CI], 0.75 to 1.20; P=0.67) and processing difficulty, defined as an executive-function score or motion coherence threshold that was more than 1.5 SD from the mean (risk ratio, 0.92; 95% CI, 0.56 to 1.51; P=0.74). Risks were not increased among children with unrecognized hypoglycemia (a low interstitial glucose concentration only). The lowest blood glucose concentration, number of hypoglycemic episodes and events, and negative interstitial increment (area above the interstitial glucose concentration curve and below 47 mg per deciliter) also did not predict the outcome. In this cohort, neonatal hypoglycemia was not associated with an adverse neurologic outcome when treatment was provided to maintain a blood glucose concentration of at least 47 mg per deciliter. (Funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development and others.).
Neonatal Glycemia and Neurodevelopmental Outcomes at 2 Years
McKinlay, Christopher J.D.; Alsweiler, Jane M.; Ansell, Judith M.; Anstice, Nicola S.; Chase, J. Geoffrey; Gamble, Gregory D.; Harris, Deborah L.; Jacobs, Robert J.; Jiang, Yannan; Paudel, Nabin; Signal, Matthew; Thompson, Benjamin; Wouldes, Trecia A.; Yu, Tzu-Ying; Harding, Jane E.
2015-01-01
Background Neonatal hypoglycemia is common and can cause neurologic impairment, but evidence supporting thresholds for intervention is limited. Methods We performed a prospective cohort study involving 528 neonates with a gestational age of at least 35 weeks who were considered to be at risk for hypoglycemia; all were treated to maintain a blood glucose concentration of at least 47 mg per deciliter (2.6 mmol per liter). We intermittently measured blood glucose for up to 7 days. We continuously monitored interstitial glucose concentrations, which were masked to clinical staff. Assessment at 2 years included Bayley Scales of Infant Development III and tests of executive and visual function. Results Of 614 children, 528 were eligible, and 404 (77% of eligible children) were assessed; 216 children (53%) had neonatal hypoglycemia (blood glucose concentration, <47 mg per deciliter). Hypoglycemia, when treated to maintain a blood glucose concentration of at least 47 mg per deciliter, was not associated with an increased risk of the primary outcomes of neurosensory impairment (risk ratio, 0.95; 95% confidence interval [CI], 0.75 to 1.20; P = 0.67) and processing difficulty, defined as an executive-function score or motion coherence threshold that was more than 1.5 SD from the mean (risk ratio, 0.92; 95% CI, 0.56 to 1.51; P = 0.74). Risks were not increased among children with unrecognized hypoglycemia (a low interstitial glucose concentration only). The lowest blood glucose concentration, number of hypoglycemic episodes and events, and negative interstitial increment (area above the interstitial glucose concentration curve and below 47 mg per deciliter) also did not predict the outcome. Conclusions In this cohort, neonatal hypoglycemia was not associated with an adverse neurologic outcome when treatment was provided to maintain a blood glucose concentration of at least 47 mg per deciliter. (Funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development and others.) PMID:26465984
Wihokhoen, Benchawan; Dondorp, Arjen M; Turner, Paul; Woodrow, Charles J; Imwong, Mallika
2016-02-01
Molecular approaches offer a means of testing archived samples stored as dried blood spots in settings where standard blood cultures are not possible. Peripheral blood films are one suggested source of material, although the sensitivity of this approach has not been well defined. Thin blood smears and dried blood spots from a severe pediatric malaria study were assessed using specific polymerase chain reaction (PCR) primers to detect non-typhoidal Salmonella (NTS; MisL gene), Streptococcus pneumoniae (lytA), and Plasmodium falciparum (18S rRNA). Of 16 cases of NTS and S. pneumoniae confirmed on blood culture, none were positive by PCR using DNA extracts from blood films or dried blood spots. In contrast, four of 36 dried blood spots and two of 178 plasma samples were PCR positive for S. pneumoniae, despite negative bacterial blood cultures, suggesting false positives. Quantitative assessment revealed that the effective concentration of P. falciparum DNA in blood films was three log orders of magnitude lower than for dried blood spots. The P. falciparum kelch13 gene could not be amplified from blood films. These findings question the value of blood PCR-based approaches for detection of NTS and S. pneumoniae, and show that stored blood films are an inefficient method of studying P. falciparum. © The American Society of Tropical Medicine and Hygiene.
Wihokhoen, Benchawan; Dondorp, Arjen M.; Turner, Paul; Woodrow, Charles J.; Imwong, Mallika
2016-01-01
Molecular approaches offer a means of testing archived samples stored as dried blood spots in settings where standard blood cultures are not possible. Peripheral blood films are one suggested source of material, although the sensitivity of this approach has not been well defined. Thin blood smears and dried blood spots from a severe pediatric malaria study were assessed using specific polymerase chain reaction (PCR) primers to detect non-typhoidal Salmonella (NTS; MisL gene), Streptococcus pneumoniae (lytA), and Plasmodium falciparum (18S rRNA). Of 16 cases of NTS and S. pneumoniae confirmed on blood culture, none were positive by PCR using DNA extracts from blood films or dried blood spots. In contrast, four of 36 dried blood spots and two of 178 plasma samples were PCR positive for S. pneumoniae, despite negative bacterial blood cultures, suggesting false positives. Quantitative assessment revealed that the effective concentration of P. falciparum DNA in blood films was three log orders of magnitude lower than for dried blood spots. The P. falciparum kelch13 gene could not be amplified from blood films. These findings question the value of blood PCR-based approaches for detection of NTS and S. pneumoniae, and show that stored blood films are an inefficient method of studying P. falciparum. PMID:26711525
Aref'eva, A S; Dyban, P A; Krasil'shchikova, M S; Dobrucki, J W; Zatsepina, O V
2010-01-01
A characteristic feature of systemic autoimmune diseases along with appearance of autoantibodies targeting self-antigenes is deposition of immunoglobulins and components of the complement system in kidneys. However, mechanisms of the deposit formation and their cytotoxic effects still remain poorly studied. To elucidate these questions, we used SJL/J mice which are known to develop autoimmune process accompanied by the appearance of anti-fibrillarin antibodies following regular administrations of sublethal dozes of HgCl2. Using antibodies to the total murine ummunoglobulins we showed that immunodeposits were present in glomeruli of autoimmune and control (not-autoimmune) animals, but their intensity was directly correlated with the titer of anti-fibrillarin autoantibodies and was minimal in control mice. By confocal microscopy and conventional fluorescence microscopy it was defined that immunodeposits deeply penetrate glomeruli and are the most likely located within mesangial cells. In autoimmune animals, ummunoglobulins completely colocolized with the C3--component of complement, but not with the major autoantigen--the protein fibrillarin. We failed to determine the signs of cell proliferation or death in glomeruli. The most prominent difference between control and autoimmune mice was the presence if immunodeposits in renal blood vessels. These observations argue in favor of the idea that destructive and disfunctional renal lesions accompanying development of autoimmune diseases can be caused, in part, by accumulation of immunodeposits in blood vessels.
Campion, Thomas R; Waitman, Lemuel R; May, Addison K; Ozdas, Asli; Lorenzi, Nancy M; Gadd, Cynthia S
2010-01-01
Evaluations of computerized clinical decision support systems (CDSS) typically focus on clinical performance changes and do not include social, organizational, and contextual characteristics explaining use and effectiveness. Studies of CDSS for intensive insulin therapy (IIT) are no exception, and the literature lacks an understanding of effective computer-based IIT implementation and operation. This paper presents (1) a literature review of computer-based IIT evaluations through the lens of institutional theory, a discipline from sociology and organization studies, to demonstrate the inconsistent reporting of workflow and care process execution and (2) a single-site case study to illustrate how computer-based IIT requires substantial organizational change and creates additional complexity with unintended consequences including error. Computer-based IIT requires organizational commitment and attention to site-specific technology, workflow, and care processes to achieve intensive insulin therapy goals. The complex interaction between clinicians, blood glucose testing devices, and CDSS may contribute to workflow inefficiency and error. Evaluations rarely focus on the perspective of nurses, the primary users of computer-based IIT whose knowledge can potentially lead to process and care improvements. This paper addresses a gap in the literature concerning the social, organizational, and contextual characteristics of CDSS in general and for intensive insulin therapy specifically. Additionally, this paper identifies areas for future research to define optimal computer-based IIT process execution: the frequency and effect of manual data entry error of blood glucose values, the frequency and effect of nurse overrides of CDSS insulin dosing recommendations, and comprehensive ethnographic study of CDSS for IIT. Copyright (c) 2009. Published by Elsevier Ireland Ltd.
Blood banking and transfusion medicine for the apheresis medicine practitioner.
Jeffus, Susanne; Wehrli, Gay
2012-01-01
This article provides a concise overview of blood banking and transfusion medicine (BBTM) for the therapeutic apheresis medicine practitioner. It addresses the complete pathway from blood donor qualification to blood collection, to processing and storing blood components, to patient testing, to ordering blood components for therapeutic apheresis (TA) procedures, to preparing the component for transfusion, and finally to transfusion. The nurses, technologists, and physicians orchestrate these activities in concert to best serve patients undergoing TA procedures. Enhancing knowledge of these processes may improve the quality of patient care and the utilization of blood products. Copyright © 2012 Wiley Periodicals, Inc.
Nishimura, Motonobu; Kato, Yasuhisa; Tanaka, Tsuyoshi; Taki, Hideki; Tone, Atsuhito; Yamada, Kazunori; Suzuki, Seiji; Saito, Miho; Ando, Yutaka; Hoshiyama, Yoshiharu
2017-08-01
The Home Blood Pressure for Diabetic Nephropathy study is a prospective observational study conducted to determine the effect of home blood pressure (HBP) on remission/regression of microalbuminuria in patients with type 2 diabetes mellitus (DM). Patients with type 2 DM having microalbuminuria were followed-up for 3 years. Remission of microalbuminuria was defined as shift from microalbuminuria to normoalbuminuria. Regression of microalbuminuria was defined as a 50% reduction in urinary albumin-creatinine ratio from baseline. All measurements of morning and evening HBP were averaged every year and defined as all HBP. In total, 235 patients were followed up. The 3-year cumulative incidences of remission and regression were 32.3% and 44.7%, respectively. Following analysis of all cases, the degree of decline in all home systolic blood pressure (AHSBP), rather than mean AHSBP, influenced the incidence of remission/regression. There was a strong relationship between the decline in AHSBP during the follow-up period and AHSBP at baseline. Therefore, separate analyses of the patients with AHSBP below 140 mm Hg at baseline were performed, which revealed that mean AHSBP during the follow-up period independently affected the incidence of remission/regression. The hazard ratio for inducing remission/regression was significantly lower in patients with AHSBP during the follow-up period above 130 mm Hg than in those with AHSBP below 120 mm Hg. Optimal AHSBP for the induction of remission/regression of microalbuminuria might be below 130 mm Hg. It is required to confirm whether keeping AHSBP below 130 mm Hg leads to subsequent renoprotection or not. Trial Number UMIN000000804. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Szczepanek, Steven M; McNamara, Jeffrey T; Secor, Eric R; Natarajan, Prabitha; Guernsey, Linda A; Miller, Lauren A; Ballesteros, Enrique; Jellison, Evan; Thrall, Roger S; Andemariam, Biree
2012-11-01
Although functional asplenia from infarctions may be a major contributor to increased infectious mortality in sickle-cell disease (SCD), this relationship has not been fully defined. We used the transgenic Berkeley SCD mouse to define blood and splenic immunophenotypic differences in this model compared with C57BL/6 and hemizygous controls. In the serum of SCD mice, we found increased IgG2a and suppressed IgM, IgG2b, and IgA levels. Serum IL-6 levels in SCD mice were elevated, whereas IL-1α, CXCL10, and CCL5 levels were decreased. The blood of SCD mice had higher white blood cell counts, with an increased percentage of lymphocytes and decreases in other leukocytes. Immunophenotyping of lymphocytes revealed higher percentages of CD8(+) and T-regulatory cells and lower percentages of B cells. SCD mouse spleens exhibited histological disorganization, with reduction of defined lymphoid follicles and expansion of red pulp, a greater than fourfold increase in splenic mononuclear cells, marked expansion of the nucleated red blood cell fraction, and B-cell and CD8(+) T-cell lymphopenia. Within the splenic B-cell population, there was a significant decrease in B-1a B cells, with a corresponding decrease in IgA secreting plasma cells in the gut. Confocal microscopy of spleens demonstrated complete disruption of the normal lymphofollicular structure in the white pulp of SCD mice without distinct B, T, and marginal zones. Our findings suggest that altered SCD splenic morphological characteristics result in an impaired systemic immune response. Copyright © 2012 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Prognostic Role of Hypertensive Response to Exercise in Patients With Repaired Coarctation of Aorta.
Yogeswaran, Vidhushei; Connolly, Heidi M; Al-Otaibi, Mohamad; Ammash, Naser M; Warnes, Carole A; Said, Sameh M; Egbe, Alexander C
2018-05-01
This study aimed to determine the prevalence of hypertensive response to exercise (HRE) and its association with cardiovascular adverse events (CAEs) in patients with repaired coarctation of aorta (rCOA). We retrospectively reviewed records of adult patients with rCOA who had cardiopulmonary exercise tests (CPETs) and follow-up from 1994 to 2014 at Mayo Clinic. Patients with residual COA, defined as aortic isthmus peak velocity >2.5 m/s, were excluded. HRE was defined as peak systolic blood pressure >200 mm Hg; CAEs were defined as cardiovascular death, stroke, acute coronary syndrome, heart failure hospitalization, and left ventricular ejection fraction (LVEF) < 35%. One hundred thirty-eight patients (82 men [59%]) underwent 213 CPETs, with follow-up of 85 ± 13 months. Age at initial COA repair was 9 ± 3 years; age at initial CPET was 40 ± 13 years. HRE occurred in 26 (19%) patients, and 24 (92%) of the patients with HRE had normal resting blood pressure. There were no differences in age, blood pressure at rest, and CPET findings between patients with HRE and those with normotensive response to exercise. There were 28 CAEs in 24 patients (17%), and HRE was an independent risk factor for CAE (hazard ratio [HR], 1.46 [1.13-2.52]; P = 0.04). HRE can occur even in the setting of normal blood pressure at rest, and it is a risk factor for CAE. We speculate that patients with HRE represent a high-risk group of patients who, presumably, have occult, advanced vascular dysfunction. CPET can identify these patients. The benefit of intensive antihypertension therapy needs to be confirmed. Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Zhang, Ying-Xiu; Wang, Shu-Rong; Zhao, Jin-Shan; Chu, Zun-Hua
2016-08-01
BMI and waist circumference (WC) are the two most common anthropometric measurements for general obesity and central obesity. The present study examined the distributions of BMI and WC and their relationship with blood pressure (BP) among college students in Shandong, China. A total of 5838 college students (2915 men and 2923 women) aged 19-22 years participated in the study. Height, weight, WC, and BP of all participants were measured, and BMI and waist-to-height ratio were calculated. The BMI cutoffs recommended by the Working Group on Obesity in China were used to define underweight, normal weight, and overweight. Central obesity was defined as waist-to-height ratio of at least 0.5. High BP was defined as systolic blood pressure of at least 140 mmHg and/or diastolic blood pressure of at least 90 mmHg. All individuals were classified into four groups (Q1-Q4) according to the quartiles of BMI and WC, and the BP level, and the prevalence of high BP among the four groups was compared. The prevalences of overweight, central obesity, and high BP were 22.74, 7.85, and 8.79% for men and 8.42, 3.02, and 1.92% for women, respectively; these figures were all significantly higher in men than in women (P<0.01). In both men and women, overweight and central obesity are associated with elevated BP. College students with high BMI and high WC might have an increased risk of elevated BP. These findings emphasize the importance of the prevention of overweight and obesity to prevent future-related problems such as hypertension in young individuals.
Binns, Helen J; Campbell, Carla; Brown, Mary Jean
2007-11-01
Lead is a common environmental contaminant. Lead exposure is a preventable risk that exists in all areas of the United States. In children, lead is associated with impaired cognitive, motor, behavioral, and physical abilities. In 1991, the Centers for Disease Control and Prevention defined the blood lead level that should prompt public health actions as 10 microg/dL. Concurrently, the Centers for Disease Control and Prevention also recognized that a blood lead level of 10 microg/dL did not define a threshold for the harmful effects of lead. Research conducted since 1991 has strengthened the evidence that children's physical and mental development can be affected at blood lead levels of < 10 microg/dL. In this report we provide information to help clinicians understand blood lead levels < 10 microg/dL, identify gaps in knowledge concerning lead levels in this range, and outline strategies to reduce childhood exposures to lead. We also summarize scientific data relevant to counseling, blood lead screening, and lead-exposure risk assessment. To aid in the interpretation of blood lead levels, clinicians should understand the laboratory error range for blood lead values and, if possible, select a laboratory that achieves routine performance within +/-2 microg/dL. Clinicians should obtain an environmental history on all children they examine, provide families with lead-prevention counseling, and follow blood lead screening recommendations established for their areas. As circumstances permit, clinicians should consider referral to developmental programs for children at high risk for exposure to lead and more frequent rescreening of children with blood lead levels approaching 10 microg/dL. In addition, clinicians should direct parents to agencies and sources of information that will help them establish a lead-safe environment for their children. For these preventive strategies to succeed, partnerships between health care providers, families, and local public health and housing programs should be strengthened.
Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits.
Bellini, Luca; Veladiano, Irene A; Schrank, Magdalena; Candaten, Matteo; Mollo, Antonio
2018-02-27
Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg. Bland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered. Although mean invasive arterial blood pressure is overestimated by the device, the sensitivity of this non-invasive oscillometric monitor in detecting invasive mean pressure below 60 mmHg is acceptable but a cutoff value of 65 mmHg needs to be used.
Maskens, Carolyn; Downie, Helen; Wendt, Alison; Lima, Ana; Merkley, Lisa; Lin, Yulia; Callum, Jeannie
2014-01-01
This report provides a comprehensive analysis of transfusion errors occurring at a large teaching hospital and aims to determine key errors that are threatening transfusion safety, despite implementation of safety measures. Errors were prospectively identified from 2005 to 2010. Error data were coded on a secure online database called the Transfusion Error Surveillance System. Errors were defined as any deviation from established standard operating procedures. Errors were identified by clinical and laboratory staff. Denominator data for volume of activity were used to calculate rates. A total of 15,134 errors were reported with a median number of 215 errors per month (range, 85-334). Overall, 9083 (60%) errors occurred on the transfusion service and 6051 (40%) on the clinical services. In total, 23 errors resulted in patient harm: 21 of these errors occurred on the clinical services and two in the transfusion service. Of the 23 harm events, 21 involved inappropriate use of blood. Errors with no harm were 657 times more common than events that caused harm. The most common high-severity clinical errors were sample labeling (37.5%) and inappropriate ordering of blood (28.8%). The most common high-severity error in the transfusion service was sample accepted despite not meeting acceptance criteria (18.3%). The cost of product and component loss due to errors was $593,337. Errors occurred at every point in the transfusion process, with the greatest potential risk of patient harm resulting from inappropriate ordering of blood products and errors in sample labeling. © 2013 American Association of Blood Banks (CME).
NASA Astrophysics Data System (ADS)
Ugolini, Giovanni Stefano; Occhetta, Paola; Saccani, Alessandra; Re, Francesca; Krol, Silke; Rasponi, Marco; Redaelli, Alberto
2018-04-01
In vitro blood-brain barrier models are highly relevant for drug screening and drug development studies, due to the challenging task of understanding the transport mechanism of drug molecules through the blood-brain barrier towards the brain tissue. In this respect, microfluidics holds potential for providing microsystems that require low amounts of cells and reagent and can be potentially multiplexed for increasing the ease and throughput of the drug screening process. We here describe the design, development and validation of a microfluidic device for endothelial blood-brain barrier cell transport studies. The device comprises of two microstructured layers (top culture chamber and bottom collection chamber) sandwiching a porous membrane for the cell culture. Microstructured layers include two pairs of physical electrodes, embedded into the device layers by geometrically defined guiding channels with computationally optimized positions. These electrodes allow the use of commercial electrical measurement systems for monitoring trans-endothelial electrical resistance (TEER). We employed the designed device for performing preliminary assessment of endothelial barrier formation with murine brain endothelial cells (Br-bEnd5). Results demonstrate that cellular junctional complexes effectively form in the cultures (expression of VE-Cadherin and ZO-1) and that the TEER monitoring systems effectively detects an increase of resistance of the cultured cell layers indicative of tight junction formation. Finally, we validate the use of the described microsystem for drug transport studies demonstrating that Br-bEnd5 cells significantly hinder the transport of molecules (40 kDa and 4 kDa dextran) from the top culture chamber to the bottom collection chamber.
Hori, Daijiro; Hogue, Charles; Adachi, Hideo; Max, Laura; Price, Joel; Sciortino, Christopher; Zehr, Kenton; Conte, John; Cameron, Duke; Mandal, Kaushik
2016-04-01
Perioperative blood pressure management by targeting individualized optimal blood pressure, determined by cerebral blood flow autoregulation monitoring, may ensure sufficient renal perfusion. The purpose of this study was to evaluate changes in the optimal blood pressure for individual patients, determined during cardiopulmonary bypass (CPB) and during early postoperative period in intensive care unit (ICU). A secondary aim was to examine if excursions below optimal blood pressure in the ICU are associated with risk of cardiac surgery-associated acute kidney injury (CSA-AKI). One hundred and ten patients undergoing cardiac surgery had cerebral blood flow monitored with a novel technology using ultrasound tagged near infrared spectroscopy (UT-NIRS) during CPB and in the first 3 h after surgery in the ICU. The correlation flow index (CFx) was calculated as a moving, linear correlation coefficient between cerebral flow index measured using UT-NIRS and mean arterial pressure (MAP). Optimal blood pressure was defined as the MAP with the lowest CFx. Changes in optimal blood pressure in the perioperative period were observed and the association of blood pressure excursions (magnitude and duration) below the optimal blood pressure [area under the curve (AUC) < OptMAP mmHgxh] with incidence of CSA-AKI (defined using Kidney Disease: Improving Global Outcomes criteria) was examined. Optimal blood pressure during early ICU stay and CPB was correlated (r = 0.46, P < 0.0001), but was significantly higher in the ICU compared with during CPB (75 ± 8.7 vs 71 ± 10.3 mmHg, P = 0.0002). Thirty patients (27.3%) developed CSA-AKI within 48 h after the surgery. AUC < OptMAP was associated with CSA-AKI during CPB [median, 13.27 mmHgxh, interquartile range (IQR), 4.63-20.14 vs median, 6.05 mmHgxh, IQR 3.03-12.40, P = 0.008], and in the ICU (13.72 mmHgxh, IQR 5.09-25.54 vs 5.65 mmHgxh, IQR 1.71-13.07, P = 0.022). Optimal blood pressure during CPB and in the ICU was correlated. Excursions below optimal blood pressure (AUC < OptMAP mmHgXh) during perioperative period are associated with CSA-AKI. Individualized blood pressure management based on cerebral autoregulation monitoring during the perioperative period may help improve CSA-AKI-related outcomes. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Hori, Daijiro; Hogue, Charles; Adachi, Hideo; Max, Laura; Price, Joel; Sciortino, Christopher; Zehr, Kenton; Conte, John; Cameron, Duke; Mandal, Kaushik
2016-01-01
OBJECTIVES Perioperative blood pressure management by targeting individualized optimal blood pressure, determined by cerebral blood flow autoregulation monitoring, may ensure sufficient renal perfusion. The purpose of this study was to evaluate changes in the optimal blood pressure for individual patients, determined during cardiopulmonary bypass (CPB) and during early postoperative period in intensive care unit (ICU). A secondary aim was to examine if excursions below optimal blood pressure in the ICU are associated with risk of cardiac surgery-associated acute kidney injury (CSA-AKI). METHODS One hundred and ten patients undergoing cardiac surgery had cerebral blood flow monitored with a novel technology using ultrasound tagged near infrared spectroscopy (UT-NIRS) during CPB and in the first 3 h after surgery in the ICU. The correlation flow index (CFx) was calculated as a moving, linear correlation coefficient between cerebral flow index measured using UT-NIRS and mean arterial pressure (MAP). Optimal blood pressure was defined as the MAP with the lowest CFx. Changes in optimal blood pressure in the perioperative period were observed and the association of blood pressure excursions (magnitude and duration) below the optimal blood pressure [area under the curve (AUC) < OptMAP mmHgxh] with incidence of CSA-AKI (defined using Kidney Disease: Improving Global Outcomes criteria) was examined. RESULTS Optimal blood pressure during early ICU stay and CPB was correlated (r = 0.46, P < 0.0001), but was significantly higher in the ICU compared with during CPB (75 ± 8.7 vs 71 ± 10.3 mmHg, P = 0.0002). Thirty patients (27.3%) developed CSA-AKI within 48 h after the surgery. AUC < OptMAP was associated with CSA-AKI during CPB [median, 13.27 mmHgxh, interquartile range (IQR), 4.63–20.14 vs median, 6.05 mmHgxh, IQR 3.03–12.40, P = 0.008], and in the ICU (13.72 mmHgxh, IQR 5.09–25.54 vs 5.65 mmHgxh, IQR 1.71–13.07, P = 0.022). CONCLUSIONS Optimal blood pressure during CPB and in the ICU was correlated. Excursions below optimal blood pressure (AUC < OptMAP mmHgXh) during perioperative period are associated with CSA-AKI. Individualized blood pressure management based on cerebral autoregulation monitoring during the perioperative period may help improve CSA-AKI-related outcomes. PMID:26763042
[Hygiene and security management in medical biology laboratory].
Vinner, E; Odou, M F; Fovet, B; Ghnassia, J C
2013-06-01
Risk management in Medical Biology Laboratory (MBL) which includes hygiene and waste management, is an integrated process to the whole MBL organisation. It is composed of three stages: risks factors identification, grading and prioritization, and their evaluation in the system. From the legislation and NF EN ISO 15189 standard's requirements viewpoint, prevention and protection actions to implement are described, at premises level, but also at work station environment's one (human resources and equipments) towards biological, chemical, linked to gas, to ionizing or non ionizing radiations and fire riks, in order not to compromise patients safety, employees safety, and quality results. Then, although NF EN 15189 standard only enacts requirements in terms of prevention, curative actions after established blood or chemical exposure accident are defined.
Dehnavieh, Reza; Ebrahimipour, Hossein; Molavi-Taleghani, Yasamin; Vafaee-Najar, Ali; Noori Hekmat, Somayeh; Esmailzdeh, Hamid
2014-12-25
Pediatric emergency has been considered as a high risk area, and blood transfusion is known as a unique clinical measure, therefore this study was conducted with the purpose of assessing the proactive risk assessment of blood transfusion process in Pediatric Emergency of Qaem education- treatment center in Mashhad, by the Healthcare Failure Mode and Effects Analysis (HFMEA) methodology. This cross-sectional study analyzed the failure mode and effects of blood transfusion process by a mixture of quantitative-qualitative method. The proactive HFMEA was used to identify and analyze the potential failures of the process. The information of the items in HFMEA forms was collected after obtaining a consensus of experts' panel views via the interview and focus group discussion sessions. The Number of 77 failure modes were identified for 24 sub-processes enlisted in 8 processes of blood transfusion. Totally 13 failure modes were identified as non-acceptable risk (a hazard score above 8) in the blood transfusion process and were transferred to the decision tree. Root causes of high risk modes were discussed in cause-effect meetings and were classified based on the UK national health system (NHS) approved classifications model. Action types were classified in the form of acceptance (11.6%), control (74.2%) and elimination (14.2%). Recommendations were placed in 7 categories using TRIZ ("Theory of Inventive Problem Solving.") The re-engineering process for the required changes, standardizing and updating the blood transfusion procedure, root cause analysis of blood transfusion catastrophic events, patient identification bracelet, training classes and educational pamphlets for raising awareness of personnel, and monthly gathering of transfusion medicine committee have all been considered as executive strategies in work agenda in pediatric emergency.
Dehnavieh, Reza; Ebrahimipour, Hossein; Molavi-Taleghani, Yasamin; Vafaee-Najar, Ali; Hekmat, Somayeh Noori; Esmailzdeh, Hamid
2015-01-01
Introduction: Pediatric emergency has been considered as a high risk area, and blood transfusion is known as a unique clinical measure, therefore this study was conducted with the purpose of assessing the proactive risk assessment of blood transfusion process in Pediatric Emergency of Qaem education- treatment center in Mashhad, by the Healthcare Failure Mode and Effects Analysis (HFMEA) methodology. Methodology: This cross-sectional study analyzed the failure mode and effects of blood transfusion process by a mixture of quantitative-qualitative method. The proactive HFMEA was used to identify and analyze the potential failures of the process. The information of the items in HFMEA forms was collected after obtaining a consensus of experts’ panel views via the interview and focus group discussion sessions. Results: The Number of 77 failure modes were identified for 24 sub-processes enlisted in 8 processes of blood transfusion. Totally 13 failure modes were identified as non-acceptable risk (a hazard score above 8) in the blood transfusion process and were transferred to the decision tree. Root causes of high risk modes were discussed in cause-effect meetings and were classified based on the UK national health system (NHS) approved classifications model. Action types were classified in the form of acceptance (11.6%), control (74.2%) and elimination (14.2%). Recommendations were placed in 7 categories using TRIZ (“Theory of Inventive Problem Solving.”) Conclusion: The re-engineering process for the required changes, standardizing and updating the blood transfusion procedure, root cause analysis of blood transfusion catastrophic events, patient identification bracelet, training classes and educational pamphlets for raising awareness of personnel, and monthly gathering of transfusion medicine committee have all been considered as executive strategies in work agenda in pediatric emergency. PMID:25560332
Willenborg, Jörg; Huber, Claudia; Koczula, Anna; Lange, Birgit; Eisenreich, Wolfgang; Valentin-Weigand, Peter; Goethe, Ralph
2015-01-01
Streptococcus suis is a neglected zoonotic pathogen that has to adapt to the nutritional requirements in the different host niches encountered during infection and establishment of invasive diseases. To dissect the central metabolic activity of S. suis under different conditions of nutrient availability, we performed labeling experiments starting from [13C]glucose specimens and analyzed the resulting isotopologue patterns in amino acids of S. suis grown under in vitro and ex vivo conditions. In combination with classical growth experiments, we found that S. suis is auxotrophic for Arg, Gln/Glu, His, Leu, and Trp in chemically defined medium. De novo biosynthesis was shown for Ala, Asp, Ser, and Thr at high rates and for Gly, Lys, Phe, Tyr, and Val at moderate or low rates, respectively. Glucose degradation occurred mainly by glycolysis and to a minor extent by the pentose phosphate pathway. Furthermore, the exclusive formation of oxaloacetate by phosphoenolpyruvate (PEP) carboxylation became evident from the patterns in de novo synthesized amino acids. Labeling experiments with S. suis grown ex vivo in blood or cerebrospinal fluid reflected the metabolic adaptation to these host niches with different nutrient availability; however, similar key metabolic activities were identified under these conditions. This points at the robustness of the core metabolic pathways in S. suis during the infection process. The crucial role of PEP carboxylation for growth of S. suis in the host was supported by experiments with a PEP carboxylase-deficient mutant strain in blood and cerebrospinal fluid. PMID:25575595
Systolic Blood Pressure Accuracy Enhancement in the Electronic Palpation Method Using Pulse Waveform
2001-10-25
adrenalin) or vasodilating (Nipride or Nitromex) medicines. Also painkillers and anesthetics (Oxanest, Diprivan, Fentanyl and Rapifen) may have affected...the measurements. It is hard to distinguish the effects of medication and assess their relation to blood pressure errors and pulse shapes...CONCLUSION During this study, 51 cardiac operated patients were measured to define the effects of arterial stiffening on the accuracy of the
Effects of Thermal Status on Markers of Blood Coagulation During Simulated Hemorrhage
2017-06-01
analogous to the effects of salt consumption on blood pressure where individuals are often defined as “salt-sensitive” or “salt-insensitive” (40). For...Ventilatory parameters ( ventilation , tidal volume and breathing rate) were measured (body temperature and pressure saturated) using an automated gas...method of cooling rapidly decreases the mean skin temperature with little initial effect on Tcore (see Results). Experimental protocol 2 This
Hoemann, Caroline D; Hurtig, Mark; Rossomacha, Evgeny; Sun, Jun; Chevrier, Anik; Shive, Matthew S; Buschmann, Michael D
2005-12-01
Microfracture is a surgical procedure that is used to treat focal articular cartilage defects. Although joint function improves following microfracture, the procedure elicits incomplete repair. As blood clot formation in the microfracture defect is an essential initiating event in microfracture therapy, we hypothesized that the repair would be improved if the microfracture defect were filled with a blood clot that was stabilized by the incorporation of a thrombogenic and adhesive polymer, specifically, chitosan. The objectives of the present study were to evaluate (1) blood clot adhesion in fresh microfracture defects and (2) the quality of the repair, at six months postoperatively, of microfracture defects that had been treated with or without chitosan-glycerol phosphate/blood clot implants, using a sheep model. In eighteen sheep, two 1-cm2 full-thickness chondral defects were created in the distal part of the femur and treated with microfracture; one defect was made in the medial femoral condyle, and the other defect was made in the trochlea. In four sheep, microfracture defects were created bilaterally; the microfracture defects in one knee received no further treatment, and the microfracture defects in the contralateral knee were filled with chitosan-glycerol phosphate/autologous whole blood and the implants were allowed to solidify. Fresh defects in these four sheep were collected at one hour postoperatively to compare the retention of the chitosan-glycerol phosphate/blood clot with that of the normal clot and to define the histologic characteristics of these fresh defects. In the other fourteen sheep, microfracture defects were made in only one knee and either were left untreated (control group; six sheep) or were treated with chitosan-glycerol phosphate/blood implant (treatment group; eight sheep), and the quality of repair was assessed histologically, histomorphometrically, and biochemically at six months postoperatively. In the defects that were examined one hour postoperatively, chitosan-glycerol phosphate/blood clots showed increased adhesion to the walls of the defects as compared with the blood clots in the untreated microfracture defects. After histological processing, all blood clots in the control microfracture defects had been lost, whereas chitosanglycerol phosphate/blood clot adhered to and was partly retained on the surfaces of the defect. At six months, defects that had been treated with chitosan-glycerol phosphate/blood were filled with significantly more hyaline repair tissue (p < 0.05) compared with control defects. Repair tissue from medial femoral condyle defects that had been treated with chitosan-glycerol phosphate/blood contained more cells and more collagen compared with control defects and showed complete restoration of glycosaminoglycan levels. Solidification of a chitosan-glycerol phosphate/blood implant in microfracture defects improved cartilage repair compared with microfracture alone by increasing the amount of tissue and improving its biochemical composition and cellular organization.
Marjanović, Ivan; Marjanović, Marija; Martinez, Antonio; Marković, Vujica; Božić, Marija; Stojanov, Vesna
2016-11-04
To evaluate the relationship between retrobulbar hemodynamic parameters in the ophthalmic artery (OA), central retinal artery, and short posterior ciliary artery and 24-hour blood pressure (BP) measurements in dipper and nondipper patients with primary open-angle glaucoma (POAG). A prospective, cross-sectional, and observational study was conducted on consecutive patients, referred or recruited, attending the outpatient service of our ophthalmology department. Ambulatory BP monitoring, Doppler imaging, and ocular pulse amplitude measurements were performed on the same day. Patients with nocturnal BP decrease up to 10% of the diurnal BP were defined as dippers and those with BP decrease less than 10% were defined as nondippers. A total of 114 patients (36 nondippers and 78 dippers) were included in the study. The end-diastolic velocity was significantly lower and the resistivity index (RI) was significantly higher in the dippers than in the nondippers (p<0.0001 and p<0.0001, respectively). The RI in the OA was significantly correlated with daytime and nighttime systolic BP and with the daytime mean arterial pressure in the dippers. The RI in the OA significantly correlates with BP in patients with POAG with nocturnal BP dips. Additionally, retrobulbar blood flow parameters are reduced in dippers as compared with nondippers with POAG.
Thrombocytosis in systemic lupus erythematosus: a possible clue to autosplenectomy?
Castellino, Gabriella; Govoni, Marcello; Prandini, Napoleone; Limpido, Gessica; Bernardi, Simone; Campione, Diana; Lanza, Francesco; Trotta, Francesco
2007-07-01
Thrombocytosis can be due to a myeloproliferative disorder or to a reactive or secondary process; among these are connective tissue disorders, in particular systemic lupus erythematosus (SLE). Besides being an expression of active disease, this unusual finding has also been described in SLE complicated by autosplenectomy. We evaluated the prevalence of thrombocytosis in a series of SLE patients and its relationship to functional asplenia. Platelet count was evaluated in 465 consecutive Caucasian patients with SLE (387 women, 78 men, median age 54 yrs). Thrombocytosis was defined as platelet count > 400 x 10(9)/l in at least 3 blood samples. All patients with thrombocytosis underwent peripheral blood smears for erythrocyte abnormalities and instrumental spleen evaluation. Seventeen patients (3.7%) with thrombocytosis were observed. Peripheral blood smear showed Howell-Jolly bodies, spherocytes, and target cells in 3/17 patients (17.6%). In the same 3 patients, ultrasound and computed tomography failed to evidence the spleen, and liver-spleen scans showed absence of splenic uptake (a finding indicative of functional autosplenectomy). One satisfied criteria for antiphospholipid syndrome (APS), and the other 2 patients had positive IgG antiphospholipid antibodies (aPL) at medium titer. The sudden appearance and persistence of thrombocytosis or even the apparent reversal of thrombocytopenia in patients with SLE should raise suspicion of autosplenectomy, in particular if secondary APS or aPL is present.
Cardiovascular regulation during sleep quantified by symbolic coupling traces
NASA Astrophysics Data System (ADS)
Suhrbier, A.; Riedl, M.; Malberg, H.; Penzel, T.; Bretthauer, G.; Kurths, J.; Wessel, N.
2010-12-01
Sleep is a complex regulated process with short periods of wakefulness and different sleep stages. These sleep stages modulate autonomous functions such as blood pressure and heart rate. The method of symbolic coupling traces (SCT) is used to analyze and quantify time-delayed coupling of these measurements during different sleep stages. The symbolic coupling traces, defined as the symmetric and diametric traces of the bivariate word distribution matrix, allow the quantification of time-delayed coupling. In this paper, the method is applied to heart rate and systolic blood pressure time series during different sleep stages for healthy controls as well as for normotensive and hypertensive patients with sleep apneas. Using the SCT, significant different cardiovascular mechanisms not only between the deep sleep and the other sleep stages but also between healthy subjects and patients can be revealed. The SCT method is applied to model systems, compared with established methods, such as cross correlation, mutual information, and cross recurrence analysis and demonstrates its advantages especially for nonstationary physiological data. As a result, SCT proves to be more specific in detecting delays of directional interactions than standard coupling analysis methods and yields additional information which cannot be measured by standard parameters of heart rate and blood pressure variability. The proposed method may help to indicate the pathological changes in cardiovascular regulation and also the effects of continuous positive airway pressure therapy on the cardiovascular system.
Direct measurement of IgM-Antigen interaction energy on individual red blood cells.
Yeow, Natasha; Tabor, Rico F; Garnier, Gil
2017-07-01
Most blood grouping tests rely on the principle of red blood cells (RBCs) agglutination. Agglutination is triggered by the binding of specific blood grouping antibodies to the corresponding RBC surface antigen on multiple cells. The interaction energies between blood grouping antibodies and antigens have been poorly defined in immunohaematology. Here for the first time, we functionalized atomic force microscope (AFM) cantilevers with the IgM form of blood grouping antibodies to probe populations of individual RBCs of different groups under physiological conditions. The force-mapping mode of AFM allowed us to measure specific antibody - antigen interactions, and simultaneously localize and quantify antigen sites on the scanned cell surface. This study provides a new insight of the interactions between IgM antibodies and its corresponding antigen. The technique and information can be translated to develop better blood typing diagnostics and optimize target-specific drug delivery for medical applications. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
2012-03-01
other blood relatives, who had cancer, list how he or she is related to you (your maternal aunt, paternal uncle, maternal first cousin, etc.), the type...hospitals to request review of the status of the mothers whose daughters we plan to contact to insure that there have been no maternal deaths in...about ANYONE in your family who has ANY type of cancer. We are interested in any cancer in a blood relative. A maternal relative is a blood relative on
Wedemeyer, Gary A.; Nelson, Nancy C.
1975-01-01
Gaussian and nonparametric (percentile estimate and tolerance interval) statistical methods were used to estimate normal ranges for blood chemistry (bicarbonate, bilirubin, calcium, hematocrit, hemoglobin, magnesium, mean cell hemoglobin concentration, osmolality, inorganic phosphorus, and pH for juvenile rainbow (Salmo gairdneri, Shasta strain) trout held under defined environmental conditions. The percentile estimate and Gaussian methods gave similar normal ranges, whereas the tolerance interval method gave consistently wider ranges for all blood variables except hemoglobin. If the underlying frequency distribution is unknown, the percentile estimate procedure would be the method of choice.
A Method for Identification and Analysis of Non-Overlapping Myeloid Immunophenotypes in Humans
Gustafson, Michael P.; Lin, Yi; Maas, Mary L.; Van Keulen, Virginia P.; Johnston, Patrick B.; Peikert, Tobias; Gastineau, Dennis A.; Dietz, Allan B.
2015-01-01
The development of flow cytometric biomarkers in human studies and clinical trials has been slowed by inconsistent sample processing, use of cell surface markers, and reporting of immunophenotypes. Additionally, the function(s) of distinct cell types as biomarkers cannot be accurately defined without the proper identification of homogeneous populations. As such, we developed a method for the identification and analysis of human leukocyte populations by the use of eight 10-color flow cytometric protocols in combination with novel software analyses. This method utilizes un-manipulated biological sample preparation that allows for the direct quantitation of leukocytes and non-overlapping immunophenotypes. We specifically designed myeloid protocols that enable us to define distinct phenotypes that include mature monocytes, granulocytes, circulating dendritic cells, immature myeloid cells, and myeloid derived suppressor cells (MDSCs). We also identified CD123 as an additional distinguishing marker for the phenotypic characterization of immature LIN-CD33+HLA-DR- MDSCs. Our approach permits the comprehensive analysis of all peripheral blood leukocytes and yields data that is highly amenable for standardization across inter-laboratory comparisons for human studies. PMID:25799053
Jarvi, S.I.; Gee, G.F.; Miller, M.M.; Briles, W.E.
1995-01-01
The B blood group system constitutes the major histocompatibility complex (Mhc) in birds. The Mhc is a cluster of genes largely devoted to the processing and presentation of antigen. The Mhc is highly polymorphic in many species and, thus, useful in the evaluation of genetic diversity for fitness traits within populations of a variety of animals. Correlations found between particular Mhc haplotypes and resistance to certain diseases emphasize the importance of understanding the functional significance of diversity of the Mhc, particularly in species threatened with extinction. As part of studies focused on genetic diversity in wild birds, serological techniques were used to define a highly polymorphic alloantigen system in seven families of Florida sandhill cranes (Grus canadensis pratensis). The results of analyses with antisera produced within the crane families and with chicken Mhc antigen-specific reagents revealed a single major alloantigen system that is likely the Mhc of the Florida sandhill crane. Preliminary experiments indicate that these crane alloantisera will provide a means of defining .the Mhc in other species of cranes.
Update on massive transfusion.
Pham, H P; Shaz, B H
2013-12-01
Massive haemorrhage requires massive transfusion (MT) to maintain adequate circulation and haemostasis. For optimal management of massively bleeding patients, regardless of aetiology (trauma, obstetrical, surgical), effective preparation and communication between transfusion and other laboratory services and clinical teams are essential. A well-defined MT protocol is a valuable tool to delineate how blood products are ordered, prepared, and delivered; determine laboratory algorithms to use as transfusion guidelines; and outline duties and facilitate communication between involved personnel. In MT patients, it is crucial to practice damage control resuscitation and to administer blood products early in the resuscitation. Trauma patients are often admitted with early trauma-induced coagulopathy (ETIC), which is associated with mortality; the aetiology of ETIC is likely multifactorial. Current data support that trauma patients treated with higher ratios of plasma and platelet to red blood cell transfusions have improved outcomes, but further clinical investigation is needed. Additionally, tranexamic acid has been shown to decrease the mortality in trauma patients requiring MT. Greater use of cryoprecipitate or fibrinogen concentrate might be beneficial in MT patients from obstetrical causes. The risks and benefits for other therapies (prothrombin complex concentrate, recombinant activated factor VII, or whole blood) are not clearly defined in MT patients. Throughout the resuscitation, the patient should be closely monitored and both metabolic and coagulation abnormalities corrected. Further studies are needed to clarify the optimal ratios of blood products, treatment based on underlying clinical disorder, use of alternative therapies, and integration of laboratory testing results in the management of massively bleeding patients.
HIROOKA, MASASHI; OCHI, HIRONORI; KOIZUMI, YOHEI; TOKUMOTO, YOSHIO; HIRAOKA, ATSUSHI; KUMAGI, TERU; ABE, MASANORI; TANAKA, HIROAKI; HIASA, YOICHI
2014-01-01
Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide. HCC is generally considered to spread via the bloodstream and local recurrence often occurs in the blood drainage area determined by computed tomography during hepatic arteriography (CTHA), despite complete ablation of the primary nodule. This study was conducted in order to prospectively assess the rate of local recurrence in the blood drainage area depicted by delayed-phase CTHA. The participants comprised 364 consecutive patients (260 men and 104 women; mean age, 67.4±8.6 years), enrolled between April, 2002 and December, 2011. The participants were divided into two groups, according to whether the ablation area covered the entire blood drainage area as defined by delayed-phase CTHA (group A) or not (group B). Local tumor progression was compared between the two groups. The median time to recurrence was significantly shorter for group B (434 days) compared to that for group A (1,474 days; P=0.0037). The cumulative local recurrence rates for group A were 0, 0 and 1.5% at 1, 3 and 5 years postoperatively, respectively, whereas the recurrence rates for group B were 3.8, 17.0 and 22.8% at 1, 3 and 5 years, respectively (P<0.0001). In conclusion, the safety margin for radiofrequency ablation should be defined as the blood drainage area and ablation should aim at acquiring adequate safety margins. PMID:24649330
Modern banking, collection, compatibility testing and storage of blood and blood components.
Green, L; Allard, S; Cardigan, R
2015-01-01
The clinical practice of blood transfusion has changed considerably over the last few decades. The potential risk of transfusion transmissible diseases has directed efforts towards the production of safe and high quality blood. All transfusion services now operate in an environment of ever-increasing regulatory controls encompassing all aspects of blood collection, processing and storage. Stringent donor selection, identification of pathogens that can be transmitted through blood, and development of technologies that can enhance the quality of blood, have all led to a substantial reduction in potential risks and complications associated with blood transfusion. In this article, we will discuss the current standards required for the manufacture of blood, starting from blood collection, through processing and on to storage. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Gifford, Sean C; Strachan, Briony C; Xia, Hui; Vörös, Eszter; Torabian, Kian; Tomasino, Taylor A; Griffin, Gary D; Lichtiger, Benjamin; Aung, Fleur M; Shevkoplyas, Sergey S
2018-01-01
The use of centrifugation-based approaches for processing donated blood into components is routine in the industrialized world, as disparate storage conditions require the rapid separation of 'whole blood' into distinct red blood cell (RBC), platelet, and plasma products. However, the logistical complications and potential cellular damage associated with centrifugation/apheresis manufacturing of blood products are well documented. The objective of this study was to evaluate a proof-of-concept system for whole blood processing, which does not employ electromechanical parts, is easily portable, and can be operated immediately after donation with minimal human labor. In a split-unit study (n = 6), full (~500mL) units of freshly-donated whole blood were divided, with one half processed by conventional centrifugation techniques and the other with the new blood separation system. Each of these processes took 2-3 hours to complete and were performed in parallel. Blood products generated by the two approaches were compared using an extensive panel of cellular and plasma quality metrics. Comparison of nearly all RBC parameters showed no significant differences between the two approaches, although the portable system generated RBC units with a slight but statistically significant improvement in 2,3-diphosphoglyceric acid concentration (p < 0.05). More notably, several markers of platelet damage were significantly and meaningfully higher in products generated with conventional centrifugation: the increase in platelet activation (assessed via P-selectin expression in platelets before and after blood processing) was nearly 4-fold higher for platelet units produced via centrifugation, and the release of pro-inflammatory mediators (soluble CD40-ligand, thromboxane B2) was significantly higher for centrifuged platelets as well (p < 0.01). This study demonstrated that a simple, passive system for separating donated blood into components may be a viable alternative to centrifugation-particularly for applications in remote or resource-limited settings, or for patients requiring highly functional platelet product.
Ballen, Karen K.; Logan, Brent R.; Laughlin, Mary J.; He, Wensheng; Ambruso, Daniel R.; Armitage, Susan E.; Beddard, Rachel L.; Bhatla, Deepika; Hwang, William Y.K.; Kiss, Joseph E.; Koegler, Gesine; Kurtzberg, Joanne; Nagler, Arnon; Oh, David; Petz, Lawrence D.; Price, Thomas H.; Quinones, Ralph R.; Ratanatharathorn, Voravit; Rizzo, J. Douglas; Sazama, Kathleen; Scaradavou, Andromachi; Schuster, Michael W.; Sender, Leonard S.; Shpall, Elizabeth J.; Spellman, Stephen R.; Sutton, Millicent; Weitekamp, Lee Ann; Wingard, John R.; Eapen, Mary
2015-01-01
Variations in cord blood manufacturing and administration are common, and the optimal practice, not known. We compared processing and banking practices at 16 public cord blood banks (CBB) in the United States, and assessed transplant outcomes on 530 single umbilical cord blood (UCB) myeloablative transplantations for hematologic malignancies, facilitated by these banks. UCB banking practices were separated into three mutually exclusive groups based on whether processing was automated or manual; units were plasma and red blood cell reduced or buffy coat production method or plasma reduced. Compared to the automated processing system for units, the day-28 neutrophil recovery was significantly lower after transplantation of units that were manually processed and plasma reduced (red cell replete) (odds ratio [OR] 0.19 p=0.001) or plasma and red cell reduced (OR 0.54, p=0.05). Day-100 survival did not differ by CBB. However, day-100 survival was better with units that were thawed with the dextran-albumin wash method compared to the “no wash” or “dilution only” techniques (OR 1.82, p=0.04). In conclusion, CBB processing has no significant effect on early (day 100) survival despite differences in kinetics of neutrophil recovery. PMID:25543094
Blood grouping based on PCR methods and agarose gel electrophoresis.
Sell, Ana Maria; Visentainer, Jeane Eliete Laguila
2015-01-01
The study of erythrocyte antigens continues to be an intense field of research, particularly after the development of molecular testing methods. More than 300 specificities have been described by the International Society for Blood Transfusion as belonging to 33 blood group systems. The polymerase chain reaction (PCR) is a central tool for red blood cells (RBC) genotyping. PCR and agarose gel electrophoresis are low cost, easy, and versatile in vitro methods for amplifying defined target DNA (RBC polymorphic region). Multiplex-PCR, AS-PCR (Specific Allele Polymerase Chain Reaction), and RFLP-PCR (Restriction Fragment Length Polymorphism-Polymerase Chain Reaction) techniques are usually to identify RBC polymorphisms. Furthermore, it is an easy methodology to implement. This chapter describes the PCR methodology and agarose gel electrophoresis to identify the polymorphisms of the Kell, Duffy, Kidd, and MNS blood group systems.
Runge-Kutta method for wall shear stress of blood flow in stenosed artery
NASA Astrophysics Data System (ADS)
Awaludin, Izyan Syazana; Ahmad, Rokiah@Rozita
2014-06-01
A mathematical model of blood flow through stenotic artery is considered. A stenosis is defined as the partial occlusion of the blood vessels due to the accumulation of cholesterols, fats and the abnormal growth of tissue on the artery walls. The development of stenosis in the artery is one of the factors that cause problem in blood circulation system. This study was conducted to determine the wall shear stress of blood flow in stenosed artery. Modified mathematical model is used to analyze the relationship of the wall shear stress versus the length and height of stenosis. The existing models that have been created by previous researchers are solved using fourth order Runge-Kutta method. Numerical results show that the wall shear stress is proportionate to the length and height of stenosis.
Quantitative analysis of skin flap blood flow in the rat using laser Doppler velocimetry.
Marks, N J
1985-01-01
Two experiments carried out on rat skin flaps are described, where microvascular flow has been measured noninvasively by a laser Doppler velocimeter. Using this technique it is possible to define the limits of an axial pattern flap in terms of microvascular flow; this was found to increase when the flap is elevated. 'Random-pattern' perfusion is defined by a fall in flow. This recovers sequentially along the flap, and at a constant rate at all sites. A differential in microvascular perfusion is thus maintained along a random-pattern flap for at least the first postoperative week. In a second experiment it is shown that there appears to be a linear relationship between the reduction in skin blood flow in a random-pattern flap and the distance from the base at which the measurements are made. It is suggested that these data support the view that the blood flow in a skin flap recovers primarily from its base rather than via peripheral neovascularization, and that this is due to vascular collaterals opening within the flap rather than to a relaxation of sympathetic tone. PMID:3156992
Varlet, Vincent; De Croutte, Emma Lagroy; Augsburger, Marc; Mangin, Patrice
2013-07-01
The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning. © 2013 American Academy of Forensic Sciences.
NASA Astrophysics Data System (ADS)
Melka, Bartlomiej; Gracka, Maria; Adamczyk, Wojciech; Rojczyk, Marek; Golda, Adam; Nowak, Andrzej J.; Białecki, Ryszard A.; Ostrowski, Ziemowit
2017-08-01
In the research, a numerical Computational Fluid Dynamics (CFD) model of the pulsatile blood flow was created and analysed. A real geometry of aorta and its thoracic branches of an 8-year old patient diagnosed with a congenital heart defect - coarctation of the aorta was used. The inlet boundary condition was implemented as the User Define Function according to measured values of volumetric blood flow. The blood flow was treated as multiphase using Euler-Euler approach. Plasma was set as the primary and dominant fluid phase, with the volume fraction of 0.585. The morphological elements (RBC and WBC) were set as dispersed phases being the remaining volume fraction.
Hemocompatibility studies on a degradable polar hydrophobic ionic polyurethane (D-PHI).
Brockman, Kathryne S; Kizhakkedathu, Jayachandran N; Santerre, J Paul
2017-01-15
Biomaterial blood compatibility is a complex process that involves four key pathways, including the coagulation cascade, the complement system, platelets, and leukocytes. While many studies have addressed the initial contact of blood with homopolymeric (e.g. Teflon) or simple copolymeric (e.g. Dacron) biomaterials, relatively less attention has been given to investigating blood coagulation with respect to complex copolymeric systems containing well defined and diverse function. The current study sought to assess the hemocompatibility of a complex polyurethane (PU) containing a unique combination of polar, hydrophobic, and ionic domains (D-PHI). This included a whole blood (WB) study, followed by tests on the intrinsic and extrinsic coagulation pathways, complement activation, platelet activation, and an assessment of the effect of leukocytes on platelet-biomaterial interactions. A small increase in blood clot formation was observed on D-PHI in WB; however, there was no significant increase in clotting via the intrinsic coagulation cascade. No significant increase in platelet adhesion and only a very slight increase in platelet activation were observed in comparison to albumin-coated substrates (negative control). D-PHI showed mild complement activation and increased initiation of the extrinsic pathway of coagulation, along with the observation that leukocytes were important in mediating platelet-biomaterial interactions. It is proposed that complement is responsible for activating coagulation by inciting leukocytes to generate tissue factor (TF), which causes extrinsic pathway activation. This low level of blood clotting on D-PHI's surface may be necessary for the beneficial wound healing of vascular constructs that has been previously reported for this material. Understanding the hemocompatibility of devices intended for blood-contacting applications is important for predicting device failure. Hemocompatibility is a complex parameter (affected by at least four different mechanisms) that measures the level of thrombus generation and immune system activation resulting from blood-biomaterial contact. The complexity of hemocompatibility implies that homopolymers are unlikely to solve the clotting challenges that face most biomaterials. Diversity in surface chemistry (containing hydrophobic, ionic, and polar domains) obtained from engineered polyurethanes can lead to favourable interactions with blood. The current research considered the effect of a highly functionalized polyurethane biomaterial on all four mechanisms in order to provide a comprehensive in vitro measure of the hemocompatibility of this unique material and the important mechanisms at play. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Red Blood Cell Agglutination for Blood Typing Within Passive Microfluidic Biochips.
Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud
2018-04-19
Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.
Facilitation of blood donation amongst haemochromatosis patients.
Marrow, B; Clarkson, J; Chapman, C E; Masson, S
2015-08-01
The standard medical therapy for haemochromatosis is iron removal by regular phlebotomy. Current guidelines suggest that this blood should be made available through national blood services. Here, we describe a pilot facilitating the process of blood donation amongst uncomplicated haemochromatosis patients. At a dedicated clinic, patients with uncomplicated haemochromatosis interested in becoming blood donors were offered an information leaflet and self-referral application. Upon receipt, members of the local Blood Service contacted them to confirm eligibility to donate. Data on demographics and clinical characteristics, including HFE (high Fe) genotype, co-morbidities, alcohol consumption and body mass index, were collected. Since establishing the clinic, 140 patients have attended (93 male) with median age 57. Most (n = 125; 89%) had uncomplicated haemochromatosis. Of these, 55 were potentially eligible blood donors. Amongst those eligible, there are now 29 regular blood donors, including 23 new. There is an interest and willingness to donate blood through the Blood Service amongst uncomplicated haemochromatosis patients undergoing therapeutic phlebotomy. Since the introduction of this facilitation process, we have significantly increased the number of regular donors amongst this cohort. If this process was to be replicated more widely across the UK, this could have a significant impact on the blood donor pool. © 2015 British Blood Transfusion Society.
Evaluation of canine red blood cell quality after processing with an automated cell salvage device.
Hofbauer, Nina; Windberger, Ursula; Schwendenwein, Ilse; Tichy, Alexander; Eberspächer, Eva
2016-05-01
To evaluate the properties of RBC concentrate harvested after processing fresh whole blood units from healthy dogs with an automated cell salvage device. Prospective, in vitro, experimental study. University teaching hospital. Sixteen healthy, privately owned dogs of various breeds. Fresh canine whole blood collected in bags with citrate phosphate dextrose adenine solution was processed with an automated cell salvage device and analyzed in vitro. Laboratory values determined before (baseline, from a catheter sample) and after processing RBCs (procRBCs) included a complete blood count, selected blood chemistry analytes, erythrocyte osmotic resistance, whole blood viscosity, RBC aggregation, and RBC deformability. Total recovery of RBCs was 80% ± 12%. Hematocrit of the procRBCs yielded by the device was 77% ± 3.7% (mean ± standard deviation). Gross morphology of the RBCs remained unchanged. The mean corpuscular volume, erythrocyte osmotic resistance, RBC deformability, RBC aggregation, and the activity of lactate dehydrogenase showed minor but statistically significant changes from baseline. No differences in the concentrations of free hemoglobin were observed. Whole blood viscosity was less in the procRBCs. Seventy-seven percent (mean) of the platelets were washed out, while a mean of 57% of the leukocytes remained in the procRBCs. Although processing canine blood with this automated cell salvage device leads to slight changes in some properties of RBCs, most of these changes are comparable to changes seen in human blood after processing. Present data indicate that the use of this cell salvage device does not induce changes in canine RBC concentrate that would preclude its use for transfusion. © Veterinary Emergency and Critical Care Society 2016.
Wu, Pei-Yu; Yang, Shwu-Huey; Wong, Te-Chih; Chen, Tzen-Wen; Chen, His-Hsien; Chen, Tso-Hsiao; Chen, Yu-Tong
2015-01-01
In this cross-sectional study, we hypothesized that hemodialysis patients consuming greater processed meat is associated with hypertension risk, which can be partly explained by the high sodium content in processed meat. From September 2013 to May 2014, one hundred and four patients requiring chronic hemodialysis treatment were recruited from hemodialysis centers. Data on systolic blood pressure and diastolic blood pressure before receiving dialysis, and 3-day dietary records of the recruited patients were collected. HD patients with systolic and diastolic blood pressures greater than140 mmHg and higher than 90 mmHg, respectively, were considered hypertension risk. Protein foods were divided into 4 categories: red meat, white meat, soybeans, and processed meat (e.g., sausage and ham). In a model adjusted for energy intake and hypertension history, additional servings of processed meats was positively associated to systolic blood pressure >140 mmHg (odds ratio [95% confidence interval]: 2.1 [1.0–4.3]), and diastolic blood pressure > 90 mmHg (odds ratio: 2.5 [1.2–5.5]). After adjustment for dietary sodium contents or body mass index (BMI), most associations were substantially attenuated and were no longer significant. In systolic blood pressure greater than140 mmHg, one serving per day of red meats (β = -1.22, P < .05) and white meats (β = -0. 75, P = .05) was associated with a reduced risk compared with one serving per day of processed meats. Similarly, compared with one serving per day of processed meat, a reduced risk of diastolic blood pressure higher than 90 mmHg was associated with one serving per day of red meat (β = -1. 59, P < .05), white meat (β = -0. 62, P < .05). Thus, in these hemodialysis patients, intake of processed meat is significantly positively associated with higher blood pressure risk, and both sodium contents in processed meat and BMI significantly contributes to this association. PMID:26517837
Cord blood clinical processing, cryopreservation, and storage.
Elmoazzen, Heidi; Holovati, Jelena L
2015-01-01
Allogeneic umbilical cord blood (UCB) hematopoietic stem cell transplantation has become a crucial advancement in the treatment for a variety of diseases including hematopoietic and non-hematopoietic malignancies, BM failure syndromes, hemoglobinopathies, and metabolic and immunodeficiency disorders. It has been well documented that the success of UCB engraftment is tied to UCB banking processes, and now there are established guidelines for standardization of collection, banking, processing, and cryopreservation for unrelated UCB units with purpose of achieving consistent production of high quality placental and UCB units for administration. In 2011, Canada's Ministry of Health has announced Canada's first national, publicly funded umbilical cord blood bank, which aims to provide altruistic donations for unrelated allogeneic hematopoietic stem cell transplant. In this chapter, we describe specific protocols for clinical processing, cryopreservation, and storage of UCB used by the Canadian Blood Services National Public Umbilical Cord Blood Bank.
Phosphate homeostasis and its role in bone health.
Penido, Maria Goretti M G; Alon, Uri S
2012-11-01
Phosphate is one of the most abundant minerals in the body, and its serum levels are regulated by a complex set of processes occurring in the intestine, skeleton, and kidneys. The currently known main regulators of phosphate homeostasis include parathyroid hormone (PTH), calcitriol, and a number of peptides collectively known as the "phosphatonins" of which fibroblast growth factor-23 (FGF-23) has been best defined. Maintenance of extracellular and intracellular phosphate levels within a narrow range is important for many biological processes, including energy metabolism, cell signaling, regulation of protein synthesis, skeletal development, and bone integrity. The presence of adequate amounts of phosphate is critical for the process of apoptosis of mature chondrocytes in the growth plate. Without the presence of this mineral in high enough quantities, chondrocytes will not go into apoptosis, and the normal physiological chain of events that includes invasion of blood vessels and the generation of new bone will be blocked, resulting in rickets and delayed growth. In the rest of the skeleton, hypophosphatemia will result in osteomalacia due to an insufficient formation of hydroxyapatite. This review will address phosphate metabolism and its role in bone health.
Verkhratsky, Alexei; Nedergaard, Maiken; Hertz, Leif
2015-02-01
Astrocytes, which populate the grey and white mater of the brain and the spinal cord are highly heterogeneous in their morphology and function. These cells are primarily responsible for homeostasis of the central nervous system (CNS). Most central synapses are surrounded by exceedingly thin astroglial perisynaptic processes, which act as "astroglial cradle" critical for genesis, maturation and maintenance of synaptic connectivity. The perisynaptic glial processes are densely packed with numerous transporters, which provide for homeostasis of ions and neurotransmitters in the synaptic cleft, for local metabolic support and for release of astroglial derived scavengers of reactive oxygen species. Through perivascular processes astrocytes contribute to blood-brain barrier and form "glymphatic" drainage system of the CNS. Furthermore astrocytes are indispensible for glutamatergic and γ-aminobutyrate-ergic synaptic transmission being the supplier of neurotransmitters precursor glutamine via an astrocytic/neuronal cycle. Pathogenesis of many neurological disorders, including neuropsychiatric and neurodegenerative diseases is defined by loss of homeostatic function (astroglial asthenia) or remodelling of astroglial homoeostatic capabilities. Astroglial cells further contribute to neuropathologies through mounting complex defensive programme generally known as reactive astrogliosis.
Characterization of Adaptation by Morphology in a Planar Biological Network of Plasmodial Slime Mold
NASA Astrophysics Data System (ADS)
Ito, Masateru; Okamoto, Riki; Takamatsu, Atsuko
2011-07-01
Growth processes of a planar biological network of plasmodium of a true slime mold, Physarum polycephalum, were analyzed quantitatively. The plasmodium forms a transportation network through which protoplasm conveys nutrients, oxygen, and cellular organelles similarly to blood in a mammalian vascular network. To analyze the network structure, vertices were defined at tube bifurcation points. Then edges were defined for the tubes connecting both end vertices. Morphological analysis was attempted along with conventional topological analysis, revealing that the growth process of the plasmodial network structure depends on environmental conditions. In an attractive condition, the network is a polygonal lattice with more than six edges per vertex at the early stage and the hexagonal lattice at a later stage. Through all growing stages, the tube structure was not highly developed but an unstructured protoplasmic thin sheet was dominantly formed. The network size is small. In contrast, in the repulsive condition, the network is a mixture of polygonal lattice and tree-graph. More specifically, the polygonal lattice has more than six edges per vertex in the early stage, then a tree-graph structure is added to the lattice network at a later stage. The thick tube structure was highly developed. The network size, in the meaning of Euclidean distance but not topological one, grows considerably. Finally, the biological meaning of the environment-dependent network structure in the plasmodium is discussed.
Staccini, P; Joubert, M; Quaranta, J F; Fieschi, D; Fieschi, M
2000-01-01
Hospital information systems have to support quality improvement objectives. The design issues of health care information system can be classified into three categories: 1) time-oriented and event-labelled storage of patient data; 2) contextual support of decision-making; 3) capabilities for modular upgrading. The elicitation of the requirements has to meet users' needs in relation to both the quality (efficacy, safety) and the monitoring of all health care activities (traceability). Information analysts need methods to conceptualize clinical information systems that provide actors with individual benefits and guide behavioural changes. A methodology is proposed to elicit and structure users' requirements using a process-oriented analysis, and it is applied to the field of blood transfusion. An object-oriented data model of a process has been defined in order to identify its main components: activity, sub-process, resources, constrains, guidelines, parameters and indicators. Although some aspects of activity, such as "where", "what else", and "why" are poorly represented by the data model alone, this method of requirement elicitation fits the dynamic of data input for the process to be traced. A hierarchical representation of hospital activities has to be found for this approach to be generalised within the organisation, for the processes to be interrelated, and for their characteristics to be shared.
Staccini, P; Joubert, M; Quaranta, J F; Fieschi, D; Fieschi, M
2001-12-01
Healthcare institutions are looking at ways to increase their efficiency by reducing costs while providing care services with a high level of safety. Thus, hospital information systems have to support quality improvement objectives. The elicitation of the requirements has to meet users' needs in relation to both the quality (efficacy, safety) and the monitoring of all health care activities (traceability). Information analysts need methods to conceptualise clinical information systems that provide actors with individual benefits and guide behavioural changes. A methodology is proposed to elicit and structure users' requirements using a process-oriented analysis, and it is applied to the blood transfusion process. An object-oriented data model of a process has been defined in order to organise the data dictionary. Although some aspects of activity, such as 'where', 'what else', and 'why' are poorly represented by the data model alone, this method of requirement elicitation fits the dynamic of data input for the process to be traced. A hierarchical representation of hospital activities has to be found for the processes to be interrelated, and for their characteristics to be shared, in order to avoid data redundancy and to fit the gathering of data with the provision of care.
Defining ischemic burden after traumatic brain injury using 15O PET imaging of cerebral physiology.
Coles, Jonathan P; Fryer, Tim D; Smielewski, Peter; Rice, Kenneth; Clark, John C; Pickard, John D; Menon, David K
2004-02-01
Whereas postmortem ischemic damage is common in head injury, antemortem demonstration of ischemia has proven to be elusive. Although 15O positron emission tomography may be useful in this area, the technique has traditionally analyzed data within regions of interest (ROIs) to improve statistical accuracy. In head injury, such techniques are limited because of the lack of a priori knowledge regarding the location of ischemia, coexistence of hyperaemia, and difficulty in defining ischemic cerebral blood flow (CBF) and cerebral oxygen metabolism (CMRO2) levels. We report a novel method for defining disease pathophysiology following head injury. Voxel-based approaches are used to define the distribution of oxygen extraction fraction (OEF) across the entire brain; the standard deviation of this distribution provides a measure of the variability of OEF. These data are also used to integrate voxels above a threshold OEF value to produce an ROI based upon coherent physiology rather than spatial contiguity (the ischemic brain volume; IBV). However, such approaches may suffer from poor statistical accuracy, particularly in regions with low blood flow. The magnitude of these errors has been assessed in modeling experiments using the Hoffman brain phantom and modified control datasets. We conclude that this technique is a valid and useful tool for quantifying ischemic burden after traumatic brain injury.
Blood thinners are medicines that prevent blood clots from forming. They also keep existing blood clots from getting larger. Clots in your arteries, ... down your body's process of making clots. Antiplatelet drugs, such as aspirin, prevent blood cells called platelets ...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2010 CFR
2010-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Code of Federal Regulations, 2013 CFR
2013-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Code of Federal Regulations, 2012 CFR
2012-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Code of Federal Regulations, 2014 CFR
2014-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Code of Federal Regulations, 2011 CFR
2011-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Lower Blood Pressure-Induced Renal Hypoperfusion Promotes Cisplatin-Induced Nephrotoxicity.
Mizuno, Tomohiro; Hayashi, Takahiro; Shimabukuro, Yuka; Murase, Maho; Hayashi, Hiroki; Ishikawa, Kazuhiro; Takahashi, Kazuo; Yuzawa, Yukio; Yamada, Shigeki; Nagamatsu, Tadashi
2016-01-01
Cisplatin-induced nephrotoxicity primarily occurs in the proximal tubules, and tubular injuries reduce glomerular filtration rates. Lower blood pressure causes renal hypoperfusion, which promotes ischemic acute kidney injury (AKI). Our study examined the relationship between lower blood pressure-induced renal hypoperfusion and cisplatin-induced nephrotoxicity. The relationship between cisplatin use and hypoalbuminemia is not clear. This study consisted of Japanese patients who received cisplatin as the first-line chemotherapy at Fujita Health University Hospital from April 2006 to December 2012. Hypoalbuminemia was defined as serum albumin levels ≤3.5 mg/dl. Patients who experienced lower blood pressure during chemotherapy were included in the lower blood pressure group (n = 229), and those who did not were included in the normal blood pressure group (n = 743). Total cisplatin dose in the normal blood pressure and lower blood pressure groups was 58.9 ± 23.8 and 55.0 ± 20.4 mg/m2, respectively. The rate of severe nephrotoxicity was higher and overall survival was shorter in the lower blood pressure group than in the normal blood pressure group. In a multivariable analysis, lower blood pressure significantly correlated with hypoalbuminemia. To prevent ischemic AKI, nutrition and cachexia controlling are important parts of cancer treatment. © 2016 S. Karger AG, Basel.
Preventing blood transfusion failures: FMEA, an effective assessment method.
Najafpour, Zhila; Hasoumi, Mojtaba; Behzadi, Faranak; Mohamadi, Efat; Jafary, Mohamadreza; Saeedi, Morteza
2017-06-30
Failure Mode and Effect Analysis (FMEA) is a method used to assess the risk of failures and harms to patients during the medical process and to identify the associated clinical issues. The aim of this study was to conduct an assessment of blood transfusion process in a teaching general hospital, using FMEA as the method. A structured FMEA was recruited in our study performed in 2014, and corrective actions were implemented and re-evaluated after 6 months. Sixteen 2-h sessions were held to perform FMEA in the blood transfusion process, including five steps: establishing the context, selecting team members, analysis of the processes, hazard analysis, and developing a risk reduction protocol for blood transfusion. Failure modes with the highest risk priority numbers (RPNs) were identified. The overall RPN scores ranged from 5 to 100 among which, four failure modes were associated with RPNs over 75. The data analysis indicated that failures with the highest RPNs were: labelling (RPN: 100), transfusion of blood or the component (RPN: 100), patient identification (RPN: 80) and sampling (RPN: 75). The results demonstrated that mis-transfusion of blood or blood component is the most important error, which can lead to serious morbidity or mortality. Provision of training to the personnel on blood transfusion, knowledge raising on hazards and appropriate preventative measures, as well as developing standard safety guidelines are essential, and must be implemented during all steps of blood and blood component transfusion.
Aristov, Alexander; Nosova, Ekaterina
2017-04-01
The paper focuses on research aimed at creating and testing a new approach to evaluate the processes of aggregation and sedimentation of red blood cells for purpose of its use in clinical laboratory diagnostics. The proposed method is based on photometric analysis of blood sample formed as a sessile drop. The results of clinical approbation of this method are given in the paper. Analysis of the processes occurring in the sample in the form of sessile drop during the process of blood cells sedimentation is described. The results of experimental studies to evaluate the effect of the droplet sample focusing properties on light radiation transmittance are presented. It is shown that this method significantly reduces the sample volume and provides sufficiently high sensitivity to the studied processes.
Bhagat, Ali Asgar S; Hou, Han Wei; Li, Leon D; Lim, Chwee Teck; Han, Jongyoon
2011-06-07
Blood is a highly complex bio-fluid with cellular components making up >40% of the total volume, thus making its analysis challenging and time-consuming. In this work, we introduce a high-throughput size-based separation method for processing diluted blood using inertial microfluidics. The technique takes advantage of the preferential cell focusing in high aspect-ratio microchannels coupled with pinched flow dynamics for isolating low abundance cells from blood. As an application of the developed technique, we demonstrate the isolation of cancer cells (circulating tumor cells (CTCs)) spiked in blood by exploiting the difference in size between CTCs and hematologic cells. The microchannel dimensions and processing parameters were optimized to enable high throughput and high resolution separation, comparable to existing CTC isolation technologies. Results from experiments conducted with MCF-7 cells spiked into whole blood indicate >80% cell recovery with an impressive 3.25 × 10(5) fold enrichment over red blood cells (RBCs) and 1.2 × 10(4) fold enrichment over peripheral blood leukocytes (PBL). In spite of a 20× sample dilution, the fast operating flow rate allows the processing of ∼10(8) cells min(-1) through a single microfluidic device. The device design can be easily customized for isolating other rare cells from blood including peripheral blood leukocytes and fetal nucleated red blood cells by simply varying the 'pinching' width. The advantage of simple label-free separation, combined with the ability to retrieve viable cells post enrichment and minimal sample pre-processing presents numerous applications for use in clinical diagnosis and conducting fundamental studies.
Gjerde, Hallvard; Verstraete, Alain G
2011-10-10
To validate a method for determining equivalent drug cutoff concentrations for tetrahydrocannabinol and amphetamine in blood and oral fluid, which ensures that the drug prevalence in samples of blood and oral fluid taken simultaneously is equal. A method using regression analysis of drug concentrations for defined percentiles in blood and oral fluid was developed. The accuracy and precision of this technique was investigated. As study populations, 311 cannabis users and 197 amphetamine users from the Rosita-2 Project were used. A total of 80 paired oral fluid and blood concentrations were needed to determine accurate regression formulae. When using the formulae to calculate drug cutoff concentrations in oral fluid corresponding to 2.0, 4.0, 6.0, 8.0 and 10.0 ng/ml tetrahydrocannabinol in blood and 200, 400, 600, 800 and 1000 ng/ml amphetamine in blood, the accuracy was better than 100 ± 20% compared to actual prevalence in blood with precision better than ± 20%. Prevalence regression may be a useful tool in estimating equivalent cutoff concentrations in blood and oral fluid. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
21 CFR 640.50 - Cryoprecipitated AHF.
Code of Federal Regulations, 2010 CFR
2010-04-01
... defined as a preparation of antihemophilic factor, which is obtained from a single unit of plasma... be plasma which may be obtained by whole blood collection or by plasmapheresis. [42 FR 21774, Apr. 29...
21 CFR 640.50 - Cryoprecipitated AHF.
Code of Federal Regulations, 2012 CFR
2012-04-01
... defined as a preparation of antihemophilic factor, which is obtained from a single unit of plasma... be plasma which may be obtained by whole blood collection or by plasmapheresis. [42 FR 21774, Apr. 29...
21 CFR 640.50 - Cryoprecipitated AHF.
Code of Federal Regulations, 2011 CFR
2011-04-01
... defined as a preparation of antihemophilic factor, which is obtained from a single unit of plasma... be plasma which may be obtained by whole blood collection or by plasmapheresis. [42 FR 21774, Apr. 29...
21 CFR 640.50 - Cryoprecipitated AHF.
Code of Federal Regulations, 2013 CFR
2013-04-01
... defined as a preparation of antihemophilic factor, which is obtained from a single unit of plasma... be plasma which may be obtained by whole blood collection or by plasmapheresis. [42 FR 21774, Apr. 29...
21 CFR 640.50 - Cryoprecipitated AHF.
Code of Federal Regulations, 2014 CFR
2014-04-01
... defined as a preparation of antihemophilic factor, which is obtained from a single unit of plasma... be plasma which may be obtained by whole blood collection or by plasmapheresis. [42 FR 21774, Apr. 29...
Transfusion service disaster planning.
Bundy, K L; Foss, M L; Stubbs, J R
2008-01-01
The Mayo Clinic, in Rochester, Minnesota, recently set forth a directive to develop a Mayo Emergency Incident Command System (MEICS) plan to respond to major disasters. The MEICS plan that was developed interfaces with national response plans to ensure effective communication and coordination between our institution and local, state, and federal agencies to establish a common language and communication structure. The MEICS plan addresses multiple aspects of dealing with resource needs during a crisis, including the need for blood and transfusion medicine services. The MEICS plan was developed to supplement our current local emergency preparedness procedures and provide a mechanism for responding to the escalating severity of an emergency to deal with situations of a magnitude that is outside the normal experience. A plan was developed to interface the existing Transfusion Medicine disaster plan standard operating procedures (SOP) with the institutional and Department of Laboratory Medicine (DLMP) MEICS plans. The first step in developing this interface was defining MEICS. Other major steps were defining the chain of command, developing a method for visually indicating who is "in charge," planning communication, defining the actions to be taken, assessing resource needs, developing flowcharts and updating SOPs, and developing a blood rationing team to deal with anticipated blood shortages. Several key features of the interface and updated disaster plan that were developed are calling trees for response personnel, plans for relocating leadership to alternative command centers, and action sheets to assist with resource assessment. The action sheets also provide documentation of key actions by response personnel.
NASA Astrophysics Data System (ADS)
Atkins, Chad G.; Buckley, Kevin; Chen, Deborah; Schulze, H. G.; Devine, Dana V.; Blades, Michael W.; Turner, Robin F. B.
2015-07-01
Modern transfusion medicine relies on the safe, secure, and cost-effective delivery of donated red blood cells (RBCs). Once isolated, RBCs are suspended in a defined additive solution and stored in plastic blood bags in which, over time, they undergo chemical, physiological, and morphological changes that may have a deleterious impact on some patients. Regulations limit the storage period to 42 days and the cells do not routinely undergo analytical testing before use. In this study, we use Raman spectroscopy to interrogate stored RBCs and we identify metabolic and cell-breakdown products, such as haemoglobin and membrane fragments, that build-up in the blood bags as the cells age. Our work points the way to the development of an instrument which could quickly and easily assess the biochemical nature of stored RBC units before they are transfused.
Docosahexaenoic Acid Levels in Blood and Metabolic Syndrome in Obese Children: Is There a Link?
Lassandro, Carlotta; Banderali, Giuseppe; Radaelli, Giovanni; Borghi, Elisa; Moretti, Francesca; Verduci, Elvira
2015-08-21
Prevalence of metabolic syndrome is increasing in the pediatric population. Considering the different existing criteria to define metabolic syndrome, the use of the International Diabetes Federation (IDF) criteria has been suggested in children. Docosahexaenoic acid (DHA) has been associated with beneficial effects on health. The evidence about the relationship of DHA status in blood and components of the metabolic syndrome is unclear. This review discusses the possible association between DHA content in plasma and erythrocytes and components of the metabolic syndrome included in the IDF criteria (obesity, alteration of glucose metabolism, blood lipid profile, and blood pressure) and non-alcoholic fatty liver disease in obese children. The current evidence is inconsistent and no definitive conclusion can be drawn in the pediatric population. Well-designed longitudinal and powered trials need to clarify the possible association between blood DHA status and metabolic syndrome.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murase, Kenya, E-mail: murase@sahs.med.osaka-u.ac.jp; Song, Ruixiao; Hiratsuka, Samu
We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than thosemore » without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.« less
Blockley, Nicholas P.; Griffeth, Valerie E. M.; Simon, Aaron B.; Buxton, Richard B.
2013-01-01
The dynamics of the blood oxygenation level-dependent (BOLD) response are dependent on changes in cerebral blood flow, cerebral blood volume and the cerebral metabolic rate of oxygen consumption. Furthermore, the amplitude of the response is dependent on the baseline physiological state, defined by the haematocrit, oxygen extraction fraction and cerebral blood volume. As a result of this complex dependence, the accurate interpretation of BOLD data and robust intersubject comparisons when the baseline physiology is varied are difficult. The calibrated BOLD technique was developed to address these issues. However, the methodology is complex and its full promise has not yet been realised. In this review, the theoretical underpinnings of calibrated BOLD, and issues regarding this theory that are still to be resolved, are discussed. Important aspects of practical implementation are reviewed and reported applications of this methodology are presented. PMID:22945365
Docosahexaenoic Acid Levels in Blood and Metabolic Syndrome in Obese Children: Is There a Link?
Lassandro, Carlotta; Banderali, Giuseppe; Radaelli, Giovanni; Borghi, Elisa; Moretti, Francesca; Verduci, Elvira
2015-01-01
Prevalence of metabolic syndrome is increasing in the pediatric population. Considering the different existing criteria to define metabolic syndrome, the use of the International Diabetes Federation (IDF) criteria has been suggested in children. Docosahexaenoic acid (DHA) has been associated with beneficial effects on health. The evidence about the relationship of DHA status in blood and components of the metabolic syndrome is unclear. This review discusses the possible association between DHA content in plasma and erythrocytes and components of the metabolic syndrome included in the IDF criteria (obesity, alteration of glucose metabolism, blood lipid profile, and blood pressure) and non-alcoholic fatty liver disease in obese children. The current evidence is inconsistent and no definitive conclusion can be drawn in the pediatric population. Well-designed longitudinal and powered trials need to clarify the possible association between blood DHA status and metabolic syndrome. PMID:26307979
A prospective study of impaired fasting glucose and type 2 diabetes in China: The Kailuan study.
Vaidya, Anand; Cui, Liufu; Sun, Lixia; Lu, Bing; Chen, Shuohua; Liu, Xing; Zhou, Yong; Liu, Xiurong; Xie, Xiaobing; Hu, Frank B; Wu, Shouling; Gao, Xiang
2016-11-01
The worldwide prevalence and incidence of diabetes and obesity are increasing in pandemic proportions. This is particularly relevant for China, where an extremely large population is growing, aging, and urbanizing. We thus conducted a prospective study to examine the prevalence and incidence of impaired fasting glucose (IFG) and diabetes, the rate at which fasting blood glucose rises, and the major modifiable risk factors associated with these outcomes in a large Chinese population from the Kailuan prospective study.A prospective cohort included 100,279 Chinese participants, aged 18 years or more, who had available information on fasting blood glucose concentrations at the start of the study (2006). Examination surveys were conducted every 2 years in 2008 and 2010. For the analyses of incident diabetes, we included 76,869 participants who were free of diabetes, cardiovascular disease, and cancer at the baseline and participants in the 2008 and/or 2010 follow-up. Diabetes was defined by a fasting blood glucose concentration ≥7 mmol/L, self-reported history, or active treatment with insulin or any oral hypoglycemic agent. IFG was defined by a fasting blood glucose concentration between 5.6 and 6.9 mmol/L.During the 4-year study, the prevalence of diabetes and IFG rose from 6.6% to 7.7%, and 17.3% to 22.6%, respectively. There were 17,811 incident cases of IFG and 4867 incident cases of diabetes. The age-standardized incident rate of IFG and diabetes were 62.6/1000 person-years (51.2/1000 person-years in women and 73.8/1000 person-years in men) and 10.0/1000 person-years (7.8/1000 person-years in women and 12.1/1000 person-years in men), respectively. We observed steady increases in fasting blood glucose with body anthropometrics and in every defined category of body mass index, including in those traditionally considered to be well within the "normal" range.In this large longitudinal study of Chinese adults, we observed a high prevalence and incidence of IFG and diabetes over 4 years of follow-up. Our findings are alarming for Chinese public health since steady rises in fasting blood glucose were seen across all permutations of body habitus, even apparently very lean individuals.
Blood flow and blood cell interactions and migration in microvessels
NASA Astrophysics Data System (ADS)
Fedosov, Dmitry; Fornleitner, Julia; Gompper, Gerhard
2011-11-01
Blood flow in microcirculation plays a fundamental role in a wide range of physiological processes and pathologies in the organism. To understand and, if necessary, manipulate the course of these processes it is essential to investigate blood flow under realistic conditions including deformability of blood cells, their interactions, and behavior in the complex microvascular network which is characteristic for the microcirculation. We employ the Dissipative Particle Dynamics method to model blood as a suspension of deformable cells represented by a viscoelastic spring-network which incorporates appropriate mechanical and rheological cell-membrane properties. Blood flow is investigated in idealized geometries. In particular, migration of blood cells and their distribution in blood flow are studied with respect to various conditions such as hematocrit, flow rate, red blood cell aggregation. Physical mechanisms which govern cell migration in microcirculation and, in particular, margination of white blood cells towards the vessel wall, will be discussed. In addition, we characterize blood flow dynamics and quantify hemodynamic resistance. D.F. acknowledges the Humboldt Foundation for financial support.
Estimation of arterial baroreflex sensitivity in relation to carotid artery stiffness.
Lipponen, Jukka A; Tarvainen, Mika P; Laitinen, Tomi; Karjalainen, Pasi A; Vanninen, Joonas; Koponen, Timo; Lyyra-Laitinen, Tiina
2012-01-01
Arterial baroreflex has a significant role in regulating blood pressure. It is known that increased stiffness of the carotid sinus affects mecanotransduction of baroreceptors and therefore limits baroreceptors capability to detect changes in blood pressure. By using high resolution ultrasound video signal and continuous measurement of electrocardiogram (ECG) and blood pressure, it is possible to define elastic properties of artery simultaneously with baroreflex sensitivity parameters. In this paper dataset which consist 38 subjects, 11 diabetics and 27 healthy controls was analyzed. Use of diabetic and healthy test subjects gives wide scale of arteries with different elasticity properties, which provide opportunity to validate baroreflex and artery stiffness estimation methods.
NASA Astrophysics Data System (ADS)
Voeikov, Vladimir L.; Kondakov, Sergey E.; Buravleva, Ekaterina; Kaganovsky, Isaak; Reznikov, Mikhail
2000-05-01
An automatic device for high-temporal resolution of the process of red blood sedimentation was designed. The position of the boundary between red blood and plasma may be registered each 30 sec in several pipettes simultaneously with +/- 10 mkm precision. Fractional rates of the boundary movement are deduced with high accuracy. Data are processed by a PC and presented as velocity-time curves (ESR-grams) and the curves describing time evolution of the boundary position. Several unexpected phenomena in the process of red blood sedimentation have been revealed. Upward fast movements of the boundary up to 1 mm were noted. In patients' blood sets of 5 - 10 milliHz oscillations of sedimentation rate were usually developing at early stages of blood sedimentation. In non-diluted healthy donors' blood high amplitude periodic oscillations were either absent, or were emerging only after blood resided in pipettes for several hours. When blood was diluted to a certain degree with physiological saline or with own plasma long-term low frequency (1 - 3 milliHz) rate oscillations regularly appeared. Non-trivial dependence of patterns of ESR-grams on diluting of blood with own plasma or saline was observed. Thus, non-linear dynamic behavior of living blood has been revealed due to application of the principles of the system of technical vision for the detailed analysis of red blood sedimentation kinetics.
Schoeman, Elizna M; Lopez, Genghis H; McGowan, Eunike C; Millard, Glenda M; O'Brien, Helen; Roulis, Eileen V; Liew, Yew-Wah; Martin, Jacqueline R; McGrath, Kelli A; Powley, Tanya; Flower, Robert L; Hyland, Catherine A
2017-04-01
Blood group single nucleotide polymorphism genotyping probes for a limited range of polymorphisms. This study investigated whether massively parallel sequencing (also known as next-generation sequencing), with a targeted exome strategy, provides an extended blood group genotype and the extent to which massively parallel sequencing correctly genotypes in homologous gene systems, such as RH and MNS. Donor samples (n = 28) that were extensively phenotyped and genotyped using single nucleotide polymorphism typing, were analyzed using the TruSight One Sequencing Panel and MiSeq platform. Genes for 28 protein-based blood group systems, GATA1, and KLF1 were analyzed. Copy number variation analysis was used to characterize complex structural variants in the GYPC and RH systems. The average sequencing depth per target region was 66.2 ± 39.8. Each sample harbored on average 43 ± 9 variants, of which 10 ± 3 were used for genotyping. For the 28 samples, massively parallel sequencing variant sequences correctly matched expected sequences based on single nucleotide polymorphism genotyping data. Copy number variation analysis defined the Rh C/c alleles and complex RHD hybrids. Hybrid RHD*D-CE-D variants were correctly identified, but copy number variation analysis did not confidently distinguish between D and CE exon deletion versus rearrangement. The targeted exome sequencing strategy employed extended the range of blood group genotypes detected compared with single nucleotide polymorphism typing. This single-test format included detection of complex MNS hybrid cases and, with copy number variation analysis, defined RH hybrid genes along with the RHCE*C allele hitherto difficult to resolve by variant detection. The approach is economical compared with whole-genome sequencing and is suitable for a red blood cell reference laboratory setting. © 2017 AABB.
Haldiya, Kripa Ram; Mathur, Murli Lal; Sachdev, Raman; Saiyed, Habibulla N
2005-01-01
Background Workers working close to salt milling plants may inhale salt particles floating in the air, leading to a rise in plasma sodium, which, in turn, may increase the blood pressure and the risk of hypertension. Methods To test the above hypothesis, occupational health check-up camps were organized near salt manufacturing units and all workers were invited for a free health examination. The workers who worked with dry salt in the vicinity of salt milling plants were defined as "non-brine workers," while those working in brine pans located far away from milling plants were defined as "brine workers." Blood pressure (BP) was measured during each clinical examination. In all, 474 non-brine workers and 284 brine workers were studied. Results Mean systolic blood pressure of non-brine workers (122.1 ± 13.3 mm Hg) was significantly higher than that of brine workers (118.8 ± 12.8 mm Hg, p < 0.01). Mean diastolic blood pressure of non-brine workers (71.5 ± 10.4 mm Hg) was significantly higher than that of brine workers (69.7 ± 9.4 mm Hg, p = 0.02). The prevalence of hypertension was significantly higher in non-brine workers (12.2%) than in brine workers (7.0%, p = 0.02). Nineteen salt workers were monitored while they used face masks and spectacles, for six days. Systolic, as well as diastolic, blood pressure of these workers began declining on the third day and continued to decline on the fourth day, but remained stationary up to the sixth day. The concentration of salt particles in the breathing zone of these workers was 376 mg/m3 air. Conclusion Inhalation of salt particles in non-brine workers may be an occupational cause of increased blood pressure. PMID:16042798
Optical sensor for remote estimation of alcohol concentration in blood stream
NASA Astrophysics Data System (ADS)
Shenhav, Asaf; Brodie, Ziv; Beiderman, Yevgeny; Garcia, Javier; Mico, Vicente; Zalevsky, Zeev
2013-02-01
The purpose of this manuscript is to validate our recently developed novel optical approach for extraction of remote vibration sources as a successful technique to estimate the alcohol concentration in blood stream. This technique is based on the tracking of temporal changes of reflected secondary speckle patterns produced in human skin when being illuminated by a laser beam. Since the skin's vibrations profile is changed due to the alcohol in the blood stream, the extraction of the vibration profile can be translated into the corresponding alcohol concentration values by means of defining several parameters acting as indicators for the presence of alcohol in the blood stream. We have conducted several experimental tests showing a good correlation with conventional breath alcohol concentration measurement device when determining alcohol concentration in blood. The presented preliminary results validate the proposed optical sensor as a potentially useful device for measuring alcohol in blood stream with subjects that can be car drivers inspected by police authorities or medically monitored patients.
[Logistic and production process in a regional blood center: modeling and analysis].
Baesler, Felipe; Martínez, Cristina; Yaksic, Eduardo; Herrera, Claudia
2011-09-01
The blood supply chain is a complex system that considers different interconnected elements that have to be synchronized correctly to satisfy in quality and quantity the final patient requirements. To determine the blood center maximum production capacity, as well as the determination of the necessary changes for a future production capacity expansion. This work was developed in the Blood Center of Concepción, Chile, operations management tools were applied to model it and to propose improvement alternatives for the production process. The use of simulation is highlighted, which permitted the replication of the center behavior and the evaluation of expansion alternatives. It is possible to absorb a 100% increment in blood demand, without making major changes or investments in the production process. Also it was possible to determine the subsequent steps in terms of investments in equipment and human resources for a future expansion of the center coverage. The techniques used to model the production process of the blood center of Concepción, Chile, allowed us to analyze how it operates, to detect "bottle necks", and to support the decision making process for a future expansion of its capacity.
Circulating Tumor Cell and Cell-free Circulating Tumor DNA in Lung Cancer.
Nurwidya, Fariz; Zaini, Jamal; Putra, Andika Chandra; Andarini, Sita; Hudoyo, Achmad; Syahruddin, Elisna; Yunus, Faisal
2016-09-01
Circulating tumor cells (CTCs) are tumor cells that are separated from the primary site or metastatic lesion and disseminate in blood circulation. CTCs are considered to be part of the long process of cancer metastasis. As a 'liquid biopsy', CTC molecular examination and investigation of single cancer cells create an important opportunity for providing an understanding of cancer biology and the process of metastasis. In the last decade, we have seen dramatic development in defining the role of CTCs in lung cancer in terms of diagnosis, genomic alteration determination, treatment response and, finally, prognosis prediction. The aims of this review are to understand the basic biology and to review methods of detection of CTCs that apply to the various types of solid tumor. Furthermore, we explored clinical applications, including treatment monitoring to anticipate therapy resistance as well as biomarker analysis, in the context of lung cancer. We also explored the potential use of cell-free circulating tumor DNA (ctDNA) in the genomic alteration analysis of lung cancer.
Legal and ethical issues in safe blood transfusion.
Chandrashekar, Shivaram; Kantharaj, Ambuja
2014-09-01
Legal issues play a vital role in providing a framework for the Indian blood transfusion service (BTS), while ethical issues pave the way for quality. Despite licensing of all blood banks, failure to revamp the Drugs and Cosmetic Act (D and C Act) is impeding quality. Newer techniques like chemiluminescence or nucleic acid testing (NAT) find no mention in the D and C Act. Specialised products like pooled platelet concentrates or modified whole blood, therapeutic procedures like erythropheresis, plasma exchange, stem cell collection and processing technologies like leukoreduction and irradiation are not a part of the D and C Act. A highly fragmented BTS comprising of over 2500 blood banks, coupled with a slow and tedious process of dual licensing (state and centre) is a hindrance to smooth functioning of blood banks. Small size of blood banks compromises blood safety. New blood banks are opened in India by hospitals to meet requirements of insurance providers or by medical colleges as this a Medical Council of India (MCI) requirement. Hospital based blood banks opt for replacement donation as they are barred by law from holding camps. Demand for fresh blood, lack of components, and lack of guidelines for safe transfusion leads to continued abuse of blood. Differential pricing of blood components is difficult to explain scientifically or ethically. Accreditation of blood banks along with establishment of regional testing centres could pave the way to blood safety. National Aids Control Organisation (NACO) and National Blood Transfusion Council (NBTC) deserve a more proactive role in the licensing process. The Food and Drug Administration (FDA) needs to clarify that procedures or tests meant for enhancement of blood safety are not illegal.
Legal and ethical issues in safe blood transfusion
Chandrashekar, Shivaram; Kantharaj, Ambuja
2014-01-01
Legal issues play a vital role in providing a framework for the Indian blood transfusion service (BTS), while ethical issues pave the way for quality. Despite licensing of all blood banks, failure to revamp the Drugs and Cosmetic Act (D and C Act) is impeding quality. Newer techniques like chemiluminescence or nucleic acid testing (NAT) find no mention in the D and C Act. Specialised products like pooled platelet concentrates or modified whole blood, therapeutic procedures like erythropheresis, plasma exchange, stem cell collection and processing technologies like leukoreduction and irradiation are not a part of the D and C Act. A highly fragmented BTS comprising of over 2500 blood banks, coupled with a slow and tedious process of dual licensing (state and centre) is a hindrance to smooth functioning of blood banks. Small size of blood banks compromises blood safety. New blood banks are opened in India by hospitals to meet requirements of insurance providers or by medical colleges as this a Medical Council of India (MCI) requirement. Hospital based blood banks opt for replacement donation as they are barred by law from holding camps. Demand for fresh blood, lack of components, and lack of guidelines for safe transfusion leads to continued abuse of blood. Differential pricing of blood components is difficult to explain scientifically or ethically. Accreditation of blood banks along with establishment of regional testing centres could pave the way to blood safety. National Aids Control Organisation (NACO) and National Blood Transfusion Council (NBTC) deserve a more proactive role in the licensing process. The Food and Drug Administration (FDA) needs to clarify that procedures or tests meant for enhancement of blood safety are not illegal. PMID:25535417
Modified allocation capacitated planning model in blood supply chain management
NASA Astrophysics Data System (ADS)
Mansur, A.; Vanany, I.; Arvitrida, N. I.
2018-04-01
Blood supply chain management (BSCM) is a complex process management that involves many cooperating stakeholders. BSCM involves four echelon processes, which are blood collection or procurement, production, inventory, and distribution. This research develops an optimization model of blood distribution planning. The efficiency of decentralization and centralization policies in a blood distribution chain are compared, by optimizing the amount of blood delivered from a blood center to a blood bank. This model is developed based on allocation problem of capacitated planning model. At the first stage, the capacity and the cost of transportation are considered to create an initial capacitated planning model. Then, the inventory holding and shortage costs are added to the model. These additional parameters of inventory costs lead the model to be more realistic and accurate.
Translobular uptake patterns of environmental toxicants in the rat liver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsuda, S.; Rosenberg, A.; Nakatsugawa, T.
1988-03-01
Recent autologous blood perfusion and autoradiographic studies in this laboratory have shown that uptake of the organophosphate insecticide, parathion and its metabolite, paraoxon, by the rat liver is extremely rapid. The efficient metabolism of these organophosphorus esters during the first hepatic passage results from a favorable combination of two independent factors, i.e., the titer of biodegradation enzymes within the lobule and the mode of translobular uptake. If this scenario also applies to other chemicals, it may be possible to define their threshold doses for systemic exposure. Such a possibility has far-reaching toxicological implications, and prompted this study to explore themore » less defined of the two underlying factors, i.e., translobular uptake pattern of xenobiotics using the recently developed autologous blood recirculating liver perfusion technique. The authors have limited themselves to non-ionic chemicals to avoid complications due to active transport. Because water solubility/lipophilicity is likely to be a critical factor in the binding of xenobiotics to the blood and hepatocytes and thus in their translobular behavior, xenobiotics of varied lipophilicity were pulse-infused and their elution pattern examined in the recirculating autologous blood perfusion system. Three chemicals, i.e., 1,2- and 1,3-dichlorobenzene and 4-nitroanisole were chosen as examples of relatively water-soluble xenobiotics compared with parathion. Benzo(a)pyrene and 2,3,7,8-tetrachlorodibenzo-p-dioxin were studied as highly lipophilic toxicants.« less
Kim, Dokyung; Park, Wonhah
2017-12-01
Individuals with prehypertension have a greater risk of developing hypertension and cardiovascular disease than those with normal blood pressure. Good cardiorespiratory fitness has been associated with a reduced risk for cardiovascular diseases, but whether it is related to slower progression of early atherosclerosis is unclear. We evaluated 442 women, aged 40-60 years, with resting systolic blood pressure 120-139 mmHg and diastolic blood pressure 80-89 mmHg, defined as prehypertension in cross-sectional study. Blood glucose, blood lipids and carotid intima-media thickness (CIMT) were measured at rest. Cardiorespiratory fitness (VO 2 peak) was measured by respiratory gas exchange during a treadmill exercise test. Participants were divided into three cardiorespiratory fitness levels: low, moderate, and high. The prevalence of subclinical carotid atherosclerosis was defined as a mean carotid intima-media thickness greater than the 75 th percentile. After adjustment for various confounders, a high cardiorespiratory fitness level was associated with significantly lower SBP, DBP and CIMT compared with low and moderate fitness (p < 0.05). After adjustment for established risk factors, high and moderate fitness were each associated with significantly lower odds ratios for carotid atherosclerosis 0.74 (95% CI 0.45-0.92) and 0.70 (95% CI 0.46-0.95), respectively, compared with low fitness. Our results indicate that good cardiorespiratory fitness is associated with a slower progression of early atherosclerosis in middle-aged women. These findings are important, because they emphasize that middle-aged women can be evaluated for cardiorespiratory fitness to estimate their future risk for atherosclerotic vascular diseases.
Low cerebral blood flow is a risk factor for severe intraventricular haemorrhage
Meek, J.; Tyszczuk, L.; Elwell, C.; Wyatt, J
1999-01-01
AIMS—To investigate the relation between cerebral blood flow on the first day of postnatal life and the severity of any subsequent germinal matrix haemorrhage-intraventricular haemorrhage (GMH-IVH). METHODS—Cerebral blood flow was measured in 24 babies during the first 24 hours of life using near infrared spectroscopy. Repeated cerebral ultrasound examination was performed to define the maximum extent of GMH-IVH. Infants were classified as: normal scan, minor periventricular haemorrhage (haemorrhage that resolved), or severe GMH-IVH (haemorrhage distending the ventricles, that progressed to either post haemorrhagic dilatation or porencephalic cyst formation). RESULTS—Cerebral blood flow was significantly lower in the infants with GMH-IVH (median 7.0 ml/100 g/min) than those without haemorrhage (median 12.2 ml/100 g/min), despite no difference in carbon dioxide tension and a higher mean arterial blood pressure. On subgroup analysis, those infants with severe GMH-IVH had the lowest cerebral blood flow. CONCLUSION—A low cerebral blood flow on the first day of life is associated with the subsequent development of severe intraventricular haemorrhage. PMID:10375356
Digital microfabrication of user-defined 3D microstructures in cell-laden hydrogels.
Soman, Pranav; Chung, Peter H; Zhang, A Ping; Chen, Shaochen
2013-11-01
Complex 3D interfacial arrangements of cells are found in several in vivo biosystems such as blood vasculature, renal glomeruli, and intestinal villi. Current tissue engineering techniques fail to develop suitable 3D microenvironments to evaluate the concurrent effects of complex topography and cell encapsulation. There is a need to develop new fabrication approaches that control cell density and distribution within complex 3D features. In this work, we present a dynamic projection printing process that allows rapid construction of complex 3D structures using custom-defined computer-aided-design (CAD) files. Gelatin-methacrylate (GelMA) constructs featuring user-defined spiral, pyramid, flower, and dome micro-geometries were fabricated with and without encapsulated cells. Encapsulated cells demonstrate good cell viability across all geometries both on the scaffold surface and internal to the structures. Cells respond to geometric cues individually as well as collectively throughout the larger-scale patterns. Time-lapse observations also reveal the dynamic nature of mechanical interactions between cells and micro-geometry. When compared to conventional cell-seeding, cell encapsulation within complex 3D patterned scaffolds provides long-term control over proliferation, cell morphology, and geometric guidance. Overall, this biofabrication technique offers a flexible platform to evaluate cell interactions with complex 3D micro-features, with the ability to scale-up towards high-throughput screening platforms. © 2013 Wiley Periodicals, Inc.
Molecular Regulation of Lumen Morphogenesis Review
Datta, Anirban; Bryant, David M.; Mostov, Keith E.
2013-01-01
The asymmetric polarization of cells allows specialized functions to be performed at discrete subcellular locales. Spatiotemporal coordination of polarization between groups of cells allowed the evolution of metazoa. For instance, coordinated apical-basal polarization of epithelial and endothelial cells allows transport of nutrients and metabolites across cell barriers and tissue microenvironments. The defining feature of such tissues is the presence of a central, interconnected luminal network. Although tubular networks are present in seemingly different organ systems, such as the kidney, lung, and blood vessels, common underlying principles govern their formation. Recent studies using in vivo and in vitro models of lumen formation have shed new light on the molecular networks regulating this fundamental process. We here discuss progress in understanding common design principles underpinning de novo lumen formation and expansion. PMID:21300279
The role of pleiotrophin in bone repair.
Lamprou, Margarita; Kaspiris, Angelos; Panagiotopoulos, Elias; Giannoudis, Peter V; Papadimitriou, Evangelia
2014-12-01
Bone has an enormous capacity for growth, regeneration, and remodelling, largely due to induction of osteoblasts that are recruited to the site of bone formation. Although the pathways involved have not been fully elucidated, it is well accepted that the immediate environment of the cells is likely to play a role via cell–matrix interactions, mediated by several growth factors. Formation of new blood vessels is also significant and interdependent to bone formation, suggesting that enhancement of angiogenesis could be beneficial during the process of bone repair. Pleiotrophin (PTN), also called osteoblast-specific factor 1, is a heparin-binding angiogenic growth factor, with a well-defined and significant role in both physiological and pathological angiogenesis. In this review we summarise the existing evidence on the role of PTN in bone repair.
Meeting blood requirements following terrorist attacks: the Israeli experience.
Shinar, Eilat; Yahalom, Vered; Silverman, Barbara G
2006-11-01
Blood services worldwide must be prepared to meet surges in demand for blood components needed by casualties of domestic disasters and acts of terrorism. Israel's National Blood Services, operated by Magen David Adom, has extensive experience in managing blood collections and supply in emergencies. This review summarizes the structure and function of Magen David Adom's national blood program, and relates its experience to other practices that have been reported in the medical literature. Between 2000 and 2005, 7497 victims (85% civilians) were involved in 1645 terrorist attacks in Israel. On-site triage resulted in 967 (13%) deaths at the scene, 615 (8%) with severe injuries, 897 (12%) with moderate injuries and 5018 (67%) with mild injuries. Requests for blood averaged 1.3 blood units and 0.9 components per casualty, or 6.7 units and 4.5 components per severe and moderately injured patient. Public appeals for blood donations were managed centrally to match supply with demand and prevent wastage. This experience illustrates the advantages of a comprehensive program for managing blood operations in emergency situations. A coordinated national program can stabilize in-hospital inventories during routine activities, ensure instant access to precisely defined inventories, facilitate sufficient supply in times of disasters, and minimize outdating and wastage.
NASA Astrophysics Data System (ADS)
Saris, Anne E. C. M.; Nillesen, Maartje M.; Lopata, Richard G. P.; de Korte, Chris L.
2013-03-01
Automated segmentation of 3D echocardiographic images in patients with congenital heart disease is challenging, because the boundary between blood and cardiac tissue is poorly defined in some regions. Cardiologists mentally incorporate movement of the heart, using temporal coherence of structures to resolve ambiguities. Therefore, we investigated the merit of temporal cross-correlation for automated segmentation over the entire cardiac cycle. Optimal settings for maximum cross-correlation (MCC) calculation, based on a 3D cross-correlation based displacement estimation algorithm, were determined to obtain the best contrast between blood and myocardial tissue over the entire cardiac cycle. Resulting envelope-based as well as RF-based MCC values were used as additional external force in a deformable model approach, to segment the left-ventricular cavity in entire systolic phase. MCC values were tested against, and combined with, adaptive filtered, demodulated RF-data. Segmentation results were compared with manually segmented volumes using a 3D Dice Similarity Index (3DSI). Results in 3D pediatric echocardiographic images sequences (n = 4) demonstrate that incorporation of temporal information improves segmentation. The use of MCC values, either alone or in combination with adaptive filtered, demodulated RF-data, resulted in an increase of the 3DSI in 75% of the cases (average 3DSI increase: 0.71 to 0.82). Results might be further improved by optimizing MCC-contrast locally, in regions with low blood-tissue contrast. Reducing underestimation of the endocardial volume due to MCC processing scheme (choice of window size) and consequential border-misalignment, could also lead to more accurate segmentations. Furthermore, increasing the frame rate will also increase MCC-contrast and thus improve segmentation.
Carter, C J
2016-10-01
Even taking problems of diagnosis into account, a five-fold increase in the incidence of autism in recent decades, in the absence of any known changes in the human gene pool suggests a strong environmental influence. Numerous pollutants have been implicated in epidemiological studies, including pesticides, heavy metals, industrial solvents, air pollutants, particulate matter, bisphenol A, phthalates and flame retardants. Many genes have been implicated in autism, some of which are directly related to detoxification processes. Many are also expressed prenatally in the frontal cortex when the effects of such toxins on neurodevelopment are most relevant. To gain access to the foetal brain, toxins must pass placental and blood/brain barriers and access to maternal or children's blood necessitates passage across skin, airway and intestinal barriers. Literature survey of a subset of 206 genes, defined as prime autism susceptibility candidates from an Autworks/Genotator analysis, revealed that most could be related to barrier function at blood/brain, skin, intestinal, placental or other interfaces. These genes were highly enriched in proteome datasets from blood/brain and placental trophoblast barriers and many localised to skin, intestinal, lung, umbilical and placental compartments. Many were also components of the exosomal/transcytosis pathway that is involved in the transfer of compounds across cells themselves, rather than between them. Several are involved in the control of respiratory cilia that sweep mucus and noxious particles from the airways. A key role of autism susceptibility genes may thus relate to their ability to modulate the access of numerous toxins to children, and adults and, during gestation, to the developing foetal brain. Copyright © 2016 Elsevier Ltd. All rights reserved.
Muthard, Ryan W; Diamond, Scott L
2012-12-01
Blood clots form under flow during intravascular thrombosis or vessel leakage. Prevailing hemodynamics influence thrombus structure and may regulate contraction processes. A microfluidic device capable of flowing human blood over a side channel plugged with collagen (± tissue factor) was used to measure thrombus permeability (κ) and contraction at controlled transthrombus pressure drops. The collagen (κ(collagen)=1.98 × 10(-11) cm(2)) supported formation of a 20-µm thick platelet layer, which unexpectedly underwent massive platelet retraction on flow arrest. This contraction resulted in a 5.34-fold increase in permeability because of collagen restructuring. Without stopping flow, platelet deposits (no fibrin) had a permeability of κ(platelet)=5.45 × 10(-14) cm(2) and platelet-fibrin thrombi had κ(thrombus)=2.71 × 10(-14) cm(2) for ΔP=20.7 to 23.4 mm Hg, the first ever measurements for clots formed under arterial flow (1130 s(-1) wall shear rate). Platelet sensing of flow cessation triggered a 4.6- to 6.5-fold (n=3, P<0.05) increase in contraction rate, which was also observed in a rigid, impermeable parallel-plate microfluidic device. This triggered contraction was blocked by the myosin IIA inhibitor blebbistatin and by inhibitors of thromboxane A2 (TXA(2)) and ADP signaling. In addition, flow arrest triggered platelet intracellular calcium mobilization, which was blocked by TXA(2)/ADP inhibitors. As clots become occlusive or blood pools following vessel leakage, the flow diminishes, consequently allowing full platelet retraction. Flow dilution of ADP and thromboxane regulates platelet contractility with prevailing hemodynamics, a newly defined flow-sensing mechanism to regulate clot function.
Robert, Amélie; Boyer, Lucie; Pineault, Nicolas
2011-03-01
The development of culture processes for hematopoietic progenitors could lead to the development of a complementary source of platelets for therapeutic purposes. However, functional characterization of culture-derived platelets remains limited, which raises some uncertainties about the quality of platelets produced in vitro. The aim of this study was to define the proportion of functional platelets produced in cord blood CD34+ cell cultures. Toward this, the morphological and functional properties of culture-derived platelet-like particles (PLPs) were critically compared to that of blood platelets. Flow cytometry combined with transmission electron microscopy analyses revealed that PLPs formed a more heterogeneous population of platelets at a different stage of maturation than blood platelets. The majority of PLPs harbored the fibrinogen receptor αIIbβ3, but a significant proportion failed to maintain glycoprotein (GP)Ibα surface expression, a component of the vWF receptor essential for platelet functions. Importantly, GPIbα extracellular expression correlated closely with platelet function, as the GPIIb+ GPIbα+ PLP subfraction responded normally to agonist stimulation as evidenced by α-granule release, adhesion, spreading, and aggregation. In contrast, the GPIIb+ GPIbα⁻ subfraction was unresponsive in most functional assays and appeared to be metabolically inactive. The present study confirms that functional platelets can be generated in cord blood CD34+ cell cultures, though these are highly susceptible to ectodomain shedding of receptors associated with loss of function. Optimization of culture conditions to prevent these deleterious effects and to homogenize PLPs is necessary to improve the quality and yields of culture-derived platelets before they can be recognized as a suitable complementary source for therapeutic purposes.
Cazzaniga, Paolo; Nobile, Marco S.; Besozzi, Daniela; Bellini, Matteo; Mauri, Giancarlo
2014-01-01
The introduction of general-purpose Graphics Processing Units (GPUs) is boosting scientific applications in Bioinformatics, Systems Biology, and Computational Biology. In these fields, the use of high-performance computing solutions is motivated by the need of performing large numbers of in silico analysis to study the behavior of biological systems in different conditions, which necessitate a computing power that usually overtakes the capability of standard desktop computers. In this work we present coagSODA, a CUDA-powered computational tool that was purposely developed for the analysis of a large mechanistic model of the blood coagulation cascade (BCC), defined according to both mass-action kinetics and Hill functions. coagSODA allows the execution of parallel simulations of the dynamics of the BCC by automatically deriving the system of ordinary differential equations and then exploiting the numerical integration algorithm LSODA. We present the biological results achieved with a massive exploration of perturbed conditions of the BCC, carried out with one-dimensional and bi-dimensional parameter sweep analysis, and show that GPU-accelerated parallel simulations of this model can increase the computational performances up to a 181× speedup compared to the corresponding sequential simulations. PMID:25025072
Zhao, Yi-Fan; Zhang, Pei-Bin; Sun, Jian; Liu, Cui-Jing; Yi, Zhuan; Zhu, Li-Ping; Xu, You-Yi
2015-06-15
Here we describe the development of versatile antifouling polyethersulfone (PES) filtration membranes modified via surface grafting of zwitterionic polymers from a reactive amphiphilic copolymer additive. Amphiphilic polyethersulfone-block-poly(2-hydroxyethyl methacrylate) (PES-b-PHEMA) was beforehand designed and used as the blending additive of PES membranes prepared by phase inversion technique. The surface enriched PHEMA blocks on membrane surface acted as an anchor to immobilize the initiating site. Poly(sulfobetaine methacrylate) (PSBMA) were subsequently grafted onto the PES blend membranes by surface-initiated atom transfer radical polymerization (SI-ATRP). The analysis of surface chemistry confirmed the successful grafting of zwitterionic PSBMA brushes on PES membrane surface. The resulted PES-g-PSBMA membranes were capable of separating proteins from protein solution and oil from oil/water emulsion efficiently. Furthermore, the modified membranes showed high hydrophilicity and strongly antifouling properties due to the incorporation of well-defined PSBMA layer. In addition, the PES-g-PSBMA membranes exhibited excellent blood compatibility and durability during the washing process. The developed antifouling PES membranes are versatile and can find their applications in protein filtration, blood purification and oil/water separation, etc. Copyright © 2015 Elsevier Inc. All rights reserved.
Mesenchymal stromal cells from human perinatal tissues: From biology to cell therapy
Bieback, Karen; Brinkmann, Irena
2010-01-01
Cell-based regenerative medicine is of growing interest in biomedical research. The role of stem cells in this context is under intense scrutiny and may help to define principles of organ regeneration and develop innovative therapeutics for organ failure. Utilizing stem and progenitor cells for organ replacement has been conducted for many years when performing hematopoietic stem cell transplantation. Since the first successful transplantation of umbilical cord blood to treat hematological malignancies, non-hematopoietic stem and progenitor cell populations have recently been identified within umbilical cord blood and other perinatal and fetal tissues. A cell population entitled mesenchymal stromal cells (MSCs) emerged as one of the most intensely studied as it subsumes a variety of capacities: MSCs can differentiate into various subtypes of the mesodermal lineage, they secrete a large array of trophic factors suitable of recruiting endogenous repair processes and they are immunomodulatory. Focusing on perinatal tissues to isolate MSCs, we will discuss some of the challenges associated with these cell types concentrating on concepts of isolation and expansion, the comparison with cells derived from other tissue sources, regarding phenotype and differentiation capacity and finally their therapeutic potential. PMID:21607124
Bai, Ying; Zhang, Yuan; Hua, Jun; Yang, Xiangyu; Zhang, Xiaotian; Duan, Ming; Zhu, Xinjian; Huang, Wenhui; Chao, Jie; Zhou, Rongbin; Hu, Gang; Yao, Honghong
2016-01-01
MicroRNA-143 (miR-143) plays a critical role in various cellular processes; however, the role of miR-143 in the maintenance of blood-brain barrier (BBB) integrity remains poorly defined. Silencing miR-143 in a genetic animal model or via an anti-miR-143 lentivirus prevented the BBB damage induced by methamphetamine. miR-143, which targets p53 unregulated modulator of apoptosis (PUMA), increased the permeability of human brain endothelial cells and concomitantly decreased the expression of tight junction proteins (TJPs). Silencing miR-143 increased the expression of TJPs and protected the BBB integrity against the effects of methamphetamine treatment. PUMA overexpression increased the TJP expression through a mechanism that involved the NF-κB and p53 transcription factor pathways. Mechanistically, methamphetamine mediated up-regulation of miR-143 via sigma-1 receptor with sequential activation of the mitogen-activated protein kinase (MAPK) and phosphatidylinositol-3′ kinase (PI3K)/Akt and STAT3 pathways. These results indicated that silencing miR-143 could provide a novel therapeutic strategy for BBB damage-related vascular dysfunction. PMID:27767041
Neuroinflammation, immune system and Alzheimer disease: searching for the missing link.
Guerriero, F; Sgarlata, C; Francis, M; Maurizi, N; Faragli, A; Perna, S; Rondanelli, M; Rollone, M; Ricevuti, G
2017-10-01
Due to an increasingly aging population, Alzheimer disease (AD) represents a crucial issue for the healthcare system because of its widespread prevalence and the burden of its care needs. Several hypotheses on AD pathogenesis have been proposed and current therapeutical strategies have shown limited effectiveness. In the last decade, more evidence has supported a role for neuroinflammation and immune system dysregulation in AD. It remains unclear whether astrocytes, microglia and immune cells influence disease onset, progression or both. Amyloid-β peptides that aggregate extracellularly in the typical neuritic plaques generate a constant inflammatory environment. This causes a prolonged activation of microglial and astroglial cells that potentiate neuronal damage and provoke the alteration of the blood brain barrier (BBB), damaging the permeability of blood vessels. Recent data support the role of the BBB as a link between neuroinflammation, the immune system and AD. Hence, a thorough investigation of the neuroinflammatory and immune system pathways that impact neurodegeneration and novel exciting findings such as microglia-derived microvesicles, inflammasomes and signalosomes will ultimately enhance our understanding of the pathological process. Eventually, we should proceed with caution in defining a causal or consequential role of neuroinflammation in AD, but rather focus on identifying its exact pathological contribution.
21 CFR 640.4 - Collection of the blood.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Supervision. Blood shall be drawn from the donor by a qualified physician or under his supervision by... where the bleeding is performed. (c) Blood containers. Blood containers and donor sets shall be pyrogen... and donor set surfaces that come in contact with blood used in the processing of Heparin Whole Blood...
Luque-Oliveros, Manuel; Garcia-Carpintero, Maria Angeles; Cauli, Omar
2017-01-01
Patients undergoing cardiac surgery with extracorporeal circulation (ECC) frequently present haemorrhages as a complication associated with high morbidity and mortality. One of the factors that influences this risk is the volume of blood infused during surgery. The objective of this study was to determine the optimal volume of autologous blood that can be processed during cardiac surgery with ECC. We also determined the number of salvaged red blood cells to be reinfused into the patient in order to minimize the risk of haemorrhage in the postoperative period. This was an observational retrospective cross-sectional study performed in 162 ECC cardiac surgery patients. Data regarding the sociodemographic profiles of the patients, their pathologies and surgical treatments, and the blood volume recovered, processed, and reinfused after cell salvage were collected. We also evaluated the occurrence of postoperative haemorrhage. The volume of blood infused after cell salvage had a statistically significant effect (p < 0.01) on the risk of post-operative haemorrhage; the receiver operating characteristic sensitivity was 0.813 and the optimal blood volume cut-off was 1800 ml. The best clinical outcome (16.7% of patients presenting haemorrhages) was in patients that had received less than 1800 ml of recovered and processed autologous blood, which represented a volume of up to 580 ml reinfused red blood cells. The optimum thresholds for autologous processed blood and red blood cells reinfused into the patient were 1800 and 580 ml, respectively. Increasing these thresholds augmented the risk of haemorrhage as an immediate postoperative period complication. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Chang, Yu-Jen; Tien, Kuei-Erh; Wen, Cheng-Hao; Hsieh, Tzu-Bou; Hwang, Shiaw-Min
2014-04-01
Very small embryonic-like (VSEL) stem cells are a rare cell population present in bone marrow, cord blood and other tissues that displays a distinct small cell size and the ability to give rise to cells of the three germ layers. VSEL stem cells were reported to be discarded in the red blood cell fraction by Ficoll-Paque density gradient centrifugation during the processing of bone marrow and cord blood specimens. However, most cord blood banks do not include density gradient centrifugation in their procedures while red blood cells are removed by Hespan sedimentation following the Cord Blood Transplantation Study cord blood bank standard operating procedures (COBLT SOP). To clarify the retention of VSEL stem cells, we investigated the recovery of VSEL stem cells following COBLT SOP guidelines. The recovery of CD45(-)/Lin(-)/SSEA-4(+) VSEL stem cells of umbilical cord blood was examined by flow cytometry before and after COBLT SOP processing, and relative expression of pluripotent genes was analyzed by quantitative polymerase chain reaction. CD45(-)/Lin(-)/SSEA-4(+) VSEL stem cells were mostly recovered in the final products following COBLT SOP guidelines. The expression of pluripotent genes could be maintained at >80% in products after hetastarch (Hespan; B. Braun Medical Inc., Irvine, CA, USA) processing. The rare sub-population of CD45(-)/Lin(-)/SSEA-4(+) VSEL stem cells survived after Hespan sedimentation. This finding suggests that umbilical cord blood units cryopreserved by COBLT SOP in cord blood banks should retain most VSEL stem cells present in the un-processed specimens. Copyright © 2014 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
Rapid Separation of Bacteria from Blood—Review and Outlook
Alizadeh, Mahsa; Husseini, Ghaleb A.; McClellan, Daniel S.; Buchanan, Clara M.; Bledsoe, Colin G.; Robison, Richard A.; Blanco, Rae; Roeder, Beverly L.; Melville, Madison; Hunter, Alex K.
2017-01-01
The high morbidity and mortality rate of bloodstream infections involving antibiotic-resistant bacteria necessitate a rapid identification of the infectious organism and its resistance profile. Traditional methods based on culturing the blood typically require at least 24 h, and genetic amplification by PCR in the presence of blood components has been problematic. The rapid separation of bacteria from blood would facilitate their genetic identification by PCR or other methods so that the proper antibiotic regimen can quickly be selected for the septic patient. Microfluidic systems that separate bacteria from whole blood have been developed, but these are designed to process only microliter quantities of whole blood or only highly diluted blood. However, symptoms of clinical blood infections can be manifest with bacterial burdens perhaps as low as 10 CFU/mL, and thus milliliter quantities of blood must be processed to collect enough bacteria for reliable genetic analysis. This review considers the advantages and shortcomings of various methods to separate bacteria from blood, with emphasis on techniques that can be done in less than 10 min on milliliter-quantities of whole blood. These techniques include filtration, screening, centrifugation, sedimentation, hydrodynamic focusing, chemical capture on surfaces or beads, field-flow fractionation, and dielectrophoresis. Techniques with the most promise include screening, sedimentation, and magnetic bead capture, as they allow large quantities of blood to be processed quickly. Some microfluidic techniques can be scaled up. PMID:27160415
Wong, Kit Fai
2011-01-01
Virtual blood bank is the computer-controlled, electronically linked information management system that allows online ordering and real-time, remote delivery of blood for transfusion. It connects the site of testing to the point of care at a remote site in a real-time fashion with networked computers thus maintaining the integrity of immunohematology test results. It has taken the advantages of information and communication technologies to ensure the accuracy of patient, specimen and blood component identification and to enhance personnel traceability and system security. The built-in logics and process constraints in the design of the virtual blood bank can guide the selection of appropriate blood and minimize transfusion risk. The quality of blood inventory is ascertained and monitored, and an audit trail for critical procedures in the transfusion process is provided by the paperless system. Thus, the virtual blood bank can help ensure that the right patient receives the right amount of the right blood component at the right time. PMID:21383930
Leite, Fernanda; Leite, Ângela; Santos, Ana; Lima, Margarida; Barbosa, Joselina; Cosentino, Marco; Ribeiro, Laura
2017-01-01
Objective Predictors of subclinical inflammatory obesity (SIO) can be important tools for early therapeutic interventions in obesity-related comorbidities. Waist circumference (WC) and BMI have different SIO sensitivity. We aimed to i) identify SIO predictors and ii) investigate whether CD16+ monocytes are associated with BMI- (generally) or WC-defined (centrally) obesity. Methods Anthropometric and metabolic/endocrine (namely catecholamines, adrenaline and noradrenaline) parameters were evaluated, and CD16+ monocytes were studied by flow cytometry in the peripheral blood from 63 blood donors, and compared and correlated to each other. Multiple linear regression analysis was performed to identify variables that best predict SIO. Results CD16+ monocyte counts were similar in BMI and WC groups. CD16+ monocytes from centrally obese (CO) showed a more inflammatory pattern, as compared to non-CO subjects. WC was sensitive to lipidemia and, in CO subjects, lipidemia was associated with a more inflammatory phenotype of CD16+ monocytes. These differences were not noticed between BMI groups. Adrenaline was correlated with CD16+ monocyte expansion with a lower inflammatory pattern. Leptin, very low-density lipoprotein cholesterol (VLDL-C), and CD14 expression of CD16+ monocytes were found to be CO predictors. Conclusions WC-, but not BMI-defined obesity, was associated with a more inflammatory pattern of CD16+ monocytes, without monocyte expansion, suggesting that a monocyte maturation process rather than an independent arise of CD16+ monocytes occurs in CO. Thus, in a population with low cardiovascular risk, leptin, VLDL-C, and CD14 expression of CD16+ monocytes predict CO, constituting a putative tool for screening of SIO. PMID:28738359
Willenborg, Jörg; Huber, Claudia; Koczula, Anna; Lange, Birgit; Eisenreich, Wolfgang; Valentin-Weigand, Peter; Goethe, Ralph
2015-02-27
Streptococcus suis is a neglected zoonotic pathogen that has to adapt to the nutritional requirements in the different host niches encountered during infection and establishment of invasive diseases. To dissect the central metabolic activity of S. suis under different conditions of nutrient availability, we performed labeling experiments starting from [(13)C]glucose specimens and analyzed the resulting isotopologue patterns in amino acids of S. suis grown under in vitro and ex vivo conditions. In combination with classical growth experiments, we found that S. suis is auxotrophic for Arg, Gln/Glu, His, Leu, and Trp in chemically defined medium. De novo biosynthesis was shown for Ala, Asp, Ser, and Thr at high rates and for Gly, Lys, Phe, Tyr, and Val at moderate or low rates, respectively. Glucose degradation occurred mainly by glycolysis and to a minor extent by the pentose phosphate pathway. Furthermore, the exclusive formation of oxaloacetate by phosphoenolpyruvate (PEP) carboxylation became evident from the patterns in de novo synthesized amino acids. Labeling experiments with S. suis grown ex vivo in blood or cerebrospinal fluid reflected the metabolic adaptation to these host niches with different nutrient availability; however, similar key metabolic activities were identified under these conditions. This points at the robustness of the core metabolic pathways in S. suis during the infection process. The crucial role of PEP carboxylation for growth of S. suis in the host was supported by experiments with a PEP carboxylase-deficient mutant strain in blood and cerebrospinal fluid. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Transfusion reaction - hemolytic
... blood, your body produces antibodies to destroy the donor's blood cells. This process causes the transfusion reaction. Blood ... of transfusion reaction. Before a transfusion, recipient and donor blood are tested (cross-matched) to see if they ...
Acute mesenteric ischemia: guidelines of the World Society of Emergency Surgery.
Bala, Miklosh; Kashuk, Jeffry; Moore, Ernest E; Kluger, Yoram; Biffl, Walter; Gomes, Carlos Augusto; Ben-Ishay, Offir; Rubinstein, Chen; Balogh, Zsolt J; Civil, Ian; Coccolini, Federico; Leppaniemi, Ari; Peitzman, Andrew; Ansaloni, Luca; Sugrue, Michael; Sartelli, Massimo; Di Saverio, Salomone; Fraga, Gustavo P; Catena, Fausto
2017-01-01
Acute mesenteric ischemia (AMI) is typically defined as a group of diseases characterized by an interruption of the blood supply to varying portions of the small intestine, leading to ischemia and secondary inflammatory changes. If untreated, this process will eventuate in life threatening intestinal necrosis. The incidence is low, estimated at 0.09-0.2% of all acute surgical admissions. Therefore, although the entity is an uncommon cause of abdominal pain, diligence is always required because if untreated, mortality has consistently been reported in the range of 50%. Early diagnosis and timely surgical intervention are the cornerstones of modern treatment and are essential to reduce the high mortality associated with this entity. The advent of endovascular approaches in parallel with modern imaging techniques may provide new options. Thus, we believe that a current position paper from World Society of Emergency Surgery (WSES) is warranted, in order to put forth the most recent and practical recommendations for diagnosis and treatment of AMI. This review will address the concepts of AMI with the aim of focusing on specific areas where early diagnosis and management hold the strongest potential for improving outcomes in this disease process. Some of the key points include the prompt use of CT angiography to establish the diagnosis, evaluation of the potential for revascularization to re-establish blood flow to ischemic bowel, resection of necrotic intestine, and use of damage control techniques when appropriate to allow for re-assessment of bowel viability prior to definitive anastomosis and abdominal closure.
27 CFR 21.40 - Formula No. 12-A.
Code of Federal Regulations, 2010 CFR
2010-04-01
... chemicals. 359.Processing miscellaneous products. 430.Sterilizing and preserving solutions. (2) As a raw... chemicals (including alkaloids). 345.Processing blood and blood products. 351.Processing dyes and... medicinal chemicals. 579.Other chemicals. (3) Miscellaneous uses: 812.Product development and pilot plant...
27 CFR 21.40 - Formula No. 12-A.
Code of Federal Regulations, 2011 CFR
2011-04-01
... chemicals. 359.Processing miscellaneous products. 430.Sterilizing and preserving solutions. (2) As a raw... chemicals (including alkaloids). 345.Processing blood and blood products. 351.Processing dyes and... medicinal chemicals. 579.Other chemicals. (3) Miscellaneous uses: 812.Product development and pilot plant...
27 CFR 21.41 - Formula No. 13-A.
Code of Federal Regulations, 2011 CFR
2011-04-01
... medicinal chemicals (including alkaloids). 345.Processing blood and blood products. 349.Miscellaneous drug... photographic chemicals. 358.Processing other chemicals. 359.Processing miscellaneous products. 430.Sterilizing and preserving solutions. 481.Photoengraving and rotogravure solutions and dyes. (2) As a raw material...
27 CFR 21.41 - Formula No. 13-A.
Code of Federal Regulations, 2013 CFR
2013-04-01
.... 579.Other chemicals. (3) Miscellaneous uses: 812.Product development and pilot plant uses (own use... medicinal chemicals (including alkaloids). 345.Processing blood and blood products. 349.Miscellaneous drug... photographic chemicals. 358.Processing other chemicals. 359.Processing miscellaneous products. 430.Sterilizing...
Dyrda, Agnieszka; Cytlak, Urszula; Ciuraszkiewicz, Anna; Lipinska, Agnieszka; Cueff, Anne; Bouyer, Guillaume; Egée, Stéphane; Bennekou, Poul; Lew, Virgilio L.; Thomas, Serge L. Y.
2010-01-01
Background The mechanical, rheological and shape properties of red blood cells are determined by their cortical cytoskeleton, evolutionarily optimized to provide the dynamic deformability required for flow through capillaries much narrower than the cell's diameter. The shear stress induced by such flow, as well as the local membrane deformations generated in certain pathological conditions, such as sickle cell anemia, have been shown to increase membrane permeability, based largely on experimentation with red cell suspensions. We attempted here the first measurements of membrane currents activated by a local and controlled membrane deformation in single red blood cells under on-cell patch clamp to define the nature of the stretch-activated currents. Methodology/Principal Findings The cell-attached configuration of the patch-clamp technique was used to allow recordings of single channel activity in intact red blood cells. Gigaohm seal formation was obtained with and without membrane deformation. Deformation was induced by the application of a negative pressure pulse of 10 mmHg for less than 5 s. Currents were only detected when the membrane was seen domed under negative pressure within the patch-pipette. K+ and Cl− currents were strictly dependent on the presence of Ca2+. The Ca2+-dependent currents were transient, with typical decay half-times of about 5–10 min, suggesting the spontaneous inactivation of a stretch-activated Ca2+ permeability (PCa). These results indicate that local membrane deformations can transiently activate a Ca2+ permeability pathway leading to increased [Ca2+]i, secondary activation of Ca2+-sensitive K+ channels (Gardos channel, IK1, KCa3.1), and hyperpolarization-induced anion currents. Conclusions/Significance The stretch-activated transient PCa observed here under local membrane deformation is a likely contributor to the Ca2+-mediated effects observed during the normal aging process of red blood cells, and to the increased Ca2+ content of red cells in certain hereditary anemias such as thalassemia and sickle cell anemia. PMID:20195477
Dyrda, Agnieszka; Cytlak, Urszula; Ciuraszkiewicz, Anna; Lipinska, Agnieszka; Cueff, Anne; Bouyer, Guillaume; Egée, Stéphane; Bennekou, Poul; Lew, Virgilio L; Thomas, Serge L Y
2010-02-26
The mechanical, rheological and shape properties of red blood cells are determined by their cortical cytoskeleton, evolutionarily optimized to provide the dynamic deformability required for flow through capillaries much narrower than the cell's diameter. The shear stress induced by such flow, as well as the local membrane deformations generated in certain pathological conditions, such as sickle cell anemia, have been shown to increase membrane permeability, based largely on experimentation with red cell suspensions. We attempted here the first measurements of membrane currents activated by a local and controlled membrane deformation in single red blood cells under on-cell patch clamp to define the nature of the stretch-activated currents. The cell-attached configuration of the patch-clamp technique was used to allow recordings of single channel activity in intact red blood cells. Gigaohm seal formation was obtained with and without membrane deformation. Deformation was induced by the application of a negative pressure pulse of 10 mmHg for less than 5 s. Currents were only detected when the membrane was seen domed under negative pressure within the patch-pipette. K(+) and Cl(-) currents were strictly dependent on the presence of Ca(2+). The Ca(2+)-dependent currents were transient, with typical decay half-times of about 5-10 min, suggesting the spontaneous inactivation of a stretch-activated Ca(2+) permeability (PCa). These results indicate that local membrane deformations can transiently activate a Ca(2+) permeability pathway leading to increased [Ca(2+)](i), secondary activation of Ca(2+)-sensitive K(+) channels (Gardos channel, IK1, KCa3.1), and hyperpolarization-induced anion currents. The stretch-activated transient PCa observed here under local membrane deformation is a likely contributor to the Ca(2+)-mediated effects observed during the normal aging process of red blood cells, and to the increased Ca(2+) content of red cells in certain hereditary anemias such as thalassemia and sickle cell anemia.
The future for blood-stage vaccines against malaria.
Richards, Jack S; Beeson, James G
2009-07-01
Malaria is a leading cause of mortality and morbidity globally, and effective vaccines are urgently needed. Malaria vaccine approaches can be broadly grouped as pre-erythrocytic, blood stage and transmission blocking. This review focuses on blood-stage vaccines, and considers the evidence supporting the development of blood-stage vaccines, the advantages and challenges of this approach, potential targets, human vaccine studies and future directions. There is a strong rationale for the development of vaccines based on antigens of blood-stage parasites. Symptomatic malaria is caused by blood-stage parasitemia and acquired immunity in humans largely targets blood-stage antigens. Several candidate vaccines have proved efficacious in animal models and at least one vaccine showed partial efficacy in a clinical trial. At present, all leading candidate blood-stage antigens are merozoite proteins, located on the merozoite surface or within the apical organelles. Major challenges and priorities include overcoming antigenic diversity, identification of protective epitopes, understanding the nature and targets of protective immune responses, and defining antigen combinations that give the greatest efficacy. Additionally, objective criteria and approaches are needed to prioritize the large number of candidate antigens, and strong candidates need to be tested in clinical trials as quickly as possible.
Chen, Jing; Gu, Dongfeng; Huang, Jianfeng; Rao, Dabeeru C; Jaquish, Cashell E; Hixson, James E; Chen, Chung-Shiuan; Chen, Jichun; Lu, Fanghong; Hu, Dongsheng; Rice, Treva; Kelly, Tanika N; Hamm, L Lee; Whelton, Paul K; He, Jiang
2009-03-07
Since insulin resistance is thought to be the underlying mechanism for metabolic syndrome, affected individuals might be sensitive to a dietary sodium intervention. We aimed to examine the association between metabolic syndrome and salt sensitivity of blood pressure. 1906 Chinese participants without diabetes, aged 16 years or more, were selected to receive a low-sodium diet (51.3 mmol per day) for 7 days followed by a high-sodium diet (307.8 mmol per day) for an additional 7 days. Participants were excluded from the analysis if metabolic risk factor information was missing or if they did not complete their dietary interventions. Blood pressure was measured at baseline and on days 2, 5, 6, and 7 of each intervention. Metabolic syndrome was defined as the presence of three or more of: abdominal obesity, raised blood pressure, high triglyceride concentration, low HDL cholesterol, or high glucose. High salt sensitivity was defined as a decrease in mean arterial blood pressure of more than 5 mm Hg during low-sodium or an increase of more than 5 mm Hg during high-sodium intervention. This study is registered with ClinicalTrials.gov, number NCT00721721. Of the 1881 participants with information regarding metabolic syndrome, 283 had metabolic syndrome. 1853 participants completed the low-sodium diet and 1845 completed the high-sodium diet. Multivariable-adjusted mean changes in blood pressure were significantly greater in participants with metabolic syndrome than in those without on both low-sodium and high-sodium diets (p<0.0001 for all comparisons). Additionally, risk of salt sensitivity rose with increasing numbers of risk factors for metabolic syndrome. Compared with those with no risk factors, participants with four or five had a 3.54-fold increased odds (95% CI 2.05-6.11) of high salt-sensitivity during the low-sodium and a 3.13-fold increased odds (1.80-5.43) of high salt-sensitivity during the high-sodium intervention. These results suggest that metabolic syndrome enhances blood pressure response to sodium intake. Reduction in sodium intake could be an especially important component in reducing blood pressure in patients with multiple risk factors for metabolic syndrome.
Koh, Y I; Choi, S
2002-02-01
It has been suggested that airway eosinophilic inflammation is associated with the severity of exercise-induced bronchospasm (EIB). Blood eosinophils are known to be an indirect marker of airway inflammation in asthma. The aim of this study is to investigate that a simple and easy blood test for blood eosinphil counts may predict the severity of EIB in asthma. Seventy-seven men with perennial asthma (age range 18-23 years) were included. Lung function test, skin prick test, and blood tests for eosinophils counts and total IgE levels were performed. Methacholine bronchial provocation test and, 24 h later, free running test were carried out. EIB was defined as a 15% reduction or more in post-exercise FEV1 compared with pre-exercise FEV1 value. Atopy score was defined as a sum of mean wheal diameters to allergens. EIB was observed in 60 (78%) of 77 subjects. Asthmatics with EIB showed significantly increased percentages of eosinophils (P<0.01), log eosinophil counts (P<0.001), and atopy scores (P<0.05) and decreased log PC20 values (P < 0.05) compared with asthmatics without EIB. Asthmatics with eosinophils of > 700 microl(-1) (36.9 +/- 12.7%) had significantly greater maximal % fall in FEV1 after exercise than asthmatics with eosinophils of < 350 microl(-1) (24.7 +/- 16.6%, P <0.05). Blood eosinophil counts > 350 microl(-1) yielded the specificity of 88% and positive predictive value of 93% for the presence of EIB. When a multiple regression analysis of maximal % fall in FEV1 according to log eosinophil counts, log PC20, log IgE and atopy score was performed, only blood eosinophil counts were significant factor contributing to the maximal % fall in FEV1 after exercise. These findings not only suggest that a simple blood test for eosinophils may be useful in the prediction of the severity of EIB, but also reinforce the view that airway eosinophilic inflammation may play a major role in EIB in asthma.
Elevated Blood Lead Levels Are Associated with Reduced Risk of Malaria in Beninese Infants.
Moya-Alvarez, Violeta; Mireku, Michael Osei; Ayotte, Pierre; Cot, Michel; Bodeau-Livinec, Florence
2016-01-01
Elevated blood lead levels (BLL) and malaria carry an important burden of disease in West Africa. Both diseases might cause anemia and they might entail long-term consequences for the development and the health status of the child. Albeit the significant impact of malaria on lead levels described in Nigeria, no evaluation of the effect of elevated BLL on malaria risk has been investigated so far. Between 2010 and 2012, blood lead levels of 203 Beninese infants from Allada, a semi-rural area 50km North from Cotonou, were assessed at 12 months of age. To assess lead levels, blood samples were analyzed by mass spectrometry. In parallel, clinical, microbiological and hematological data were collected. More precisely, hemoglobin, serum ferritin, CRP, vitamin B12, folate levels, and Plasmodium falciparum parasitemia were assessed and stool samples were also analyzed. At 12 months, the mean BLL of infants was 7.41 μg/dL (CI: 65.2; 83), and 128 infants (63%) had elevated blood lead levels, defined by the CDC as BLL>5 μg/dL. Lead poisoning, defined as BLL>10 μg/dL, was found in 39 infants (19%). Twenty-five infants (12.5%) had a positive blood smear at 12 months and 144 infants were anemic (71%, hemoglobin<110 g/L). Elevated blood lead levels were significantly associated with reduced risk of a positive blood smear (AOR = 0.38, P-value = 0.048) and P. falciparum parasite density (beta-estimate = -1.42, P-value = 0.03) in logistic and negative binomial regression multivariate models, respectively, adjusted on clinical and environmental indicators. Our study shows for the first time that BLL are negatively associated with malarial risk considering other risk factors. Malaria is one of the main causes of morbidity and mortality in infants under 5 years worldwide, and lead poisoning is the 6th most important contributor to the global burden of diseases measured in disability adjusted life years (DALYs) according to the Institute of Health Metrics. In conclusion, due to the high prevalence of elevated BLL, health interventions should look forward to minimize the exposure to lead to better protect the population in West Africa.
21 CFR 640.11 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.11 General requirements. (a) Storage. Immediately after processing, the Red Blood Cells shall be placed in storage and maintained at a...
Danese, Andrea; Shalev, Idan; Williams, Benjamin S.; Caspi, Avshalom
2015-01-01
Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for four, 24 or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-Reactive Protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried Blood Spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data-collection conditions that involve processing delays. PMID:26652682
Sugden, Karen; Danese, Andrea; Shalev, Idan; Williams, Benjamin S; Caspi, Avshalom
2015-01-01
Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for 4, 24, or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-reactive protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried blood spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. We found that K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those found in samples processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data collection conditions that involve processing delays.
Hwang, In Cheol; Ahn, Hong Yup; Park, Sang Min; Shim, Jae Yong; Kim, Kyoung Kon
2013-03-01
There is scant research concerning the prediction of imminent death, and current studies simply list events "that have already occurred" around 48 h of the death. We sought to determine what events herald the onset of dying process using the length of time from "any change" to death. This is a prospective observational study with chart audit. Inclusion criteria were terminal cancer patients who passed away in a palliative care unit. The analysis was limited to 181 patients who had medical records for their final week. Commonly observed events in the terminally ill were determined and their significant changes were defined beforehand. We selected the statistically significant changes by multiple logistic regression analysis and evaluated their predictive values for "death within 48 h." The median age was 67 years and there were 103 male patients. After adjusting for age, sex, primary cancer site, metastatic site, and cancer treatment, multiple logistic regression analyses for association between the events and "death within 48 h" revealed some significant changes: confused mental state, decreased blood pressure, increased pulse pressure, low oxygen saturation, death rattle, and decreased conscious level. The events that had higher predictability for death within 48 h were decreased blood pressure and low oxygen saturation, and the positive and negative predictive values of their combination were 95.0 and 81.4%, respectively. The most reliable events to predict impending death were decreased blood pressure and low oxygen saturation.
Slavic, Ksenija; Delves, Michael J.; Prudêncio, Miguel; Talman, Arthur M.; Straschil, Ursula; Derbyshire, Elvira T.; Xu, Zhengyao; Sinden, Robert E.; Mota, Maria M.; Morin, Christophe; Tewari, Rita; Krishna, Sanjeev; Staines, Henry M.
2011-01-01
During blood infection, malarial parasites use d-glucose as their main energy source. The Plasmodium falciparum hexose transporter (PfHT), which mediates the uptake of d-glucose into parasites, is essential for survival of asexual blood-stage parasites. Recently, genetic studies in the rodent malaria model, Plasmodium berghei, found that the orthologous hexose transporter (PbHT) is expressed throughout the parasite's development within the mosquito vector, in addition to being essential during intraerythrocytic development. Here, using a d-glucose-derived specific inhibitor of plasmodial hexose transporters, compound 3361, we have investigated the importance of d-glucose uptake during liver and transmission stages of P. berghei. Initially, we confirmed the expression of PbHT during liver stage development, using a green fluorescent protein (GFP) tagging strategy. Compound 3361 inhibited liver-stage parasite development, with a 50% inhibitory concentration (IC50) of 11 μM. This process was insensitive to the external d-glucose concentration. In addition, compound 3361 inhibited ookinete development and microgametogenesis, with IC50s in the region of 250 μM (the latter in a d-glucose-sensitive manner). Consistent with our findings for the effect of compound 3361 on vector parasite stages, 1 mM compound 3361 demonstrated transmission blocking activity. These data indicate that novel chemotherapeutic interventions that target PfHT may be active against liver and, to a lesser extent, transmission stages, in addition to blood stages. PMID:21402842
Slavic, Ksenija; Delves, Michael J; Prudêncio, Miguel; Talman, Arthur M; Straschil, Ursula; Derbyshire, Elvira T; Xu, Zhengyao; Sinden, Robert E; Mota, Maria M; Morin, Christophe; Tewari, Rita; Krishna, Sanjeev; Staines, Henry M
2011-06-01
During blood infection, malarial parasites use D-glucose as their main energy source. The Plasmodium falciparum hexose transporter (PfHT), which mediates the uptake of D-glucose into parasites, is essential for survival of asexual blood-stage parasites. Recently, genetic studies in the rodent malaria model, Plasmodium berghei, found that the orthologous hexose transporter (PbHT) is expressed throughout the parasite's development within the mosquito vector, in addition to being essential during intraerythrocytic development. Here, using a D-glucose-derived specific inhibitor of plasmodial hexose transporters, compound 3361, we have investigated the importance of D-glucose uptake during liver and transmission stages of P. berghei. Initially, we confirmed the expression of PbHT during liver stage development, using a green fluorescent protein (GFP) tagging strategy. Compound 3361 inhibited liver-stage parasite development, with a 50% inhibitory concentration (IC₅₀) of 11 μM. This process was insensitive to the external D-glucose concentration. In addition, compound 3361 inhibited ookinete development and microgametogenesis, with IC₅₀s in the region of 250 μM (the latter in a D-glucose-sensitive manner). Consistent with our findings for the effect of compound 3361 on vector parasite stages, 1 mM compound 3361 demonstrated transmission blocking activity. These data indicate that novel chemotherapeutic interventions that target PfHT may be active against liver and, to a lesser extent, transmission stages, in addition to blood stages.
Unwin, Nigel; Bhopal, Raj; Hayes, Louise; White, Martin; Patel, Sheila; Ragoobirsingh, Dalip; Alberti, George
2007-01-01
To compare the prevalence, agreement and phenotypic characteristics in three ethnic groups of the new International Diabetes Federation (IDF) definition of metabolic syndrome (MS) to the World Health Organization (WHO) and national cholesterol education program (NCEP) definitions. Newcastle upon Tyne, England. Cross-sectional surveys. Chinese (171 men and 185 women), European (257 men and 301 women), and South Asian (264 men and 295 women) adults, ages 25 to 64 years. Anthropometric indices: blood pressure, fasting lipids, urine albumin-to-creatinine ratio, glucose intolerance, insulin resistance. IDF-defined MS was highly prevalent in all groups, ranging from 12.3% (95% CIs 7.4-17.2) in Chinese men to 45.5% (39.5-51.5) in South Asian men. In women, of all ethnic groups, more than 80% of those with WHO- or NCEP-defined MS also had IDF-defined MS. In men, however, agreement was less good. For example, in each ethnic group, more than a third of those with WHO-defined MS did not have IDF-defined MS. Within each ethnic group, the biological characteristics of those with MS by any definition were largely the same. However, differences existed between ethnic groups. For example, in those with IDF-defined MS, both South Asian men and women had significantly (P < .05) higher insulin resistance and significantly lower systolic and diastolic blood pressure than Europeans or Chinese. Agreement between the IDF and other definitions is better in women than men. The phenotype is similar within each ethnic group whatever the definition, but differs between groups suggesting that risks associated with MS differ by ethnic group.
Remotely detected differential pulse transit time as a stress indicator
NASA Astrophysics Data System (ADS)
Kaur, Balvinder; Tarbox, Elizabeth; Cissel, Marty; Moses, Sophia; Luthra, Megha; Vaidya, Misha; Tran, Nhien; Ikonomidou, Vasiliki N.
2015-05-01
The human cardiovascular system, controlled by the autonomic nervous system (ANS), is one of the first sites where one can see the "fight-or-flight" response due to the presence of external stressors. In this paper, we investigate the possibility of detecting mental stress using a novel measure that can be measured in a contactless manner: Pulse transit time (dPTT), which refers to the time that is required for the blood wave (BW) to cover the distance from the heart to a defined remote location in the body. Loosely related to blood pressure, PTT is a measure of blood velocity, and is also implicated in the "fight-or-flight" response. We define the differential PTT (dPTT) as the difference in PTT between two remote areas of the body, such as the forehead and the palm. Expanding our previous work on remote BW detection from visible spectrum videos, we built a system that remotely measures dPTT. Human subject data were collected under an IRB approved protocol from 15 subjects both under normal and stress states and are used to initially establish the potential use of remote dPPT detection as a stress indicator.
ACE Gene I/D Polymorphism and Obesity in 1,574 Patients with Type 2 Diabetes Mellitus.
Pan, Yan-Hong; Wang, Min; Huang, Yan-Mei; Wang, Ying-Hui; Chen, Yin-Ling; Geng, Li-Jun; Zhang, Xiao-Xi; Zhao, Hai-Lu
2016-01-01
Association between ACE gene I/D polymorphism and the risk of overweight/obesity remains controversial. We investigated the possible relationship between ACE gene I/D polymorphism and obesity in Chinese type 2 diabetes mellitus (T2DM) patients. In this study, obesity was defined as a body mass index (BMI) value ≥ 25 kg/m 2 and subjects were classified into 4 groups (lean, normal, overweight, and obese). PCR (polymerase chain reaction) was used to detect the ACE gene I/D polymorphism in T2DM patients. Metabolic measurements including blood glucose, lipid profile, and blood pressure were obtained. Frequencies of the ACE genotypes (DD, ID, and II) were not significant among the 4 groups of BMI-defined patients ( P = 0.679) while ACE II carriers showed higher systolic blood pressure (SBP) and pulse pressure (PP) (all P < 0.050). Hyperglycemia, hypertension, and dyslipidemia in these T2DM patients were found to be significantly associated with BMI. In conclusion, the relationship of ACE gene I/D polymorphism with obesity is insignificant in Chinese patients with T2DM. SBP and PP might be higher in the ACE II carriers than in the DD and ID carriers.
Xu, Gang; Takahashi, Emi; Folkerth, Rebecca D.; Haynes, Robin L.; Volpe, Joseph J.; Grant, P. Ellen; Kinney, Hannah C.
2014-01-01
High angular resolution diffusion imaging (HARDI) demonstrates transient radial coherence of telencephalic white matter in the human fetus. Our objective was to define the neuroanatomic basis of this radial coherence through correlative HARDI- and postmortem tissue analyses. Applying immunomarkers to radial glial fibers (RGFs), axons, and blood vessels in 18 cases (19 gestational weeks to 3 postnatal years), we compared their developmental profiles to HARDI tractography in brains of comparable ages (n = 11). At midgestation, radial coherence corresponded with the presence of RGFs. At 30–31 weeks, the transition from HARDI-defined radial coherence to corticocortical coherence began simultaneously with the transformation of RGFs to astrocytes. By term, both radial coherence and RGFs had disappeared. White matter axons were radial, tangential, and oblique over the second half of gestation, whereas penetrating blood vessels were consistently radial. Thus, radial coherence in the fetal white matter likely reflects a composite of RGFs, penetrating blood vessels, and radial axons of which its transient expression most closely matches that of RGFs. This study provides baseline information for interpreting radial coherence in tractography studies of the preterm brain in the assessment of the encephalopathy of prematurity. PMID:23131806
Measuring shear force transmission across a biomimetic glycocalyx
NASA Astrophysics Data System (ADS)
Bray, Isabel; Young, Dylan; Scrimgeour, Jan
Human blood vessels are lined with a low-density polymer brush known as the glycocalyx. This brush plays an active role in defining the mechanical and biochemical environment of the endothelial cell in the blood vessel wall. In addition, it is involved in the detection of mechanical stimuli, such as the shear stress from blood flowing in the vessel. In this work, we construct a biomimetic version of the glycocalyx on top of a soft deformable substrate in order to measure its ability to modulate the effects of shear stress at the endothelial cell surface. The soft substrate is stamped on to a glass substrate and then enclosed inside a microfluidic device that generates a controlled flow over the substrate. The hydrogel chemistry has been optimized so that it reliably stamps into a defined shape and has consistent mechanical properties. Fluorescent microbeads embedded in the gel allow measurement of the surface deformation, and subsequently, calculation of the shear force at the surface of the soft substrate. We investigate the effect of the major structural elements of the glycocalyx, hyaluronic acid and charged proteoglycans, on the magnitude of the shear force transmitted to the surface of the hydrogel.
Intoxicated aggression: Do alcohol and stimulants cause dose-related aggression? A review.
Kuypers, Kpc; Verkes, R J; van den Brink, W; van Amsterdam, Jgc; Ramaekers, J G
2018-06-22
Violence and drug use are significant public health challenges that are strongly linked. It is known that alcohol plays a major role in the causation of unnatural deaths and that stimulants like cocaine and amphetamine are often implicated in aggressive acts or violence. However, a clear causal relationship between these substances and aggression, and more specifically a blood concentration threshold at which intoxicated aggression emerges is lacking. In case of a crime and subsequent law enforcement, knowledge about dose-response relationships could be of pivotal importance when evaluating the role of alcohol and drugs in aggressive offences. The present review aimed to determine whether there is a causal relation between intoxication with these psychoactive substances and aggression, and to define blood concentration thresholds above which these substances elicit aggression. Empirical articles published between 2013 and 2017 and review papers containing the predefined search strings were identified through searches in the PubMed and Embase databases and additional reference list searches. The complete search query yielded 1578 publications. Initially all articles were manually screened by title and abstract. Articles with irrelevant titles, given the selected search terms and review aims were discarded. Remaining articles were carefully studied and those that did not comply with the main objectives of this review were discarded. At the end of this process, 167 titles were found eligible for review. While placebo-controlled experimental studies clearly showed a causal link between alcohol and aggression, it is evident that such a link has not yet been established for cocaine and amphetamines. In case of alcohol, it is clear that there are various individual and contextual factors that may contribute to the occurrence of an aggressive act during intoxication. A clear threshold blood alcohol concentration has not been defined yet for alcohol, but a statistically significant increase of aggression has been demonstrated at a dose of 0.75 g/kg and higher. Future studies into intoxicated aggression should include multiple doses of alcohol and stimulants and take into account individual and contextual factors. Copyright © 2018. Published by Elsevier B.V.
Pila, EA; Sullivan, JT; Wu, XZ; Fang, J; Rudko, SP; Gordy, MA; Hanington, PC
2015-01-01
Haematopoiesis is a process that is responsible for generating sufficient numbers of blood cells in the circulation and in tissues. It is central to maintenance of homeostasis within an animal, and is critical for defense against infection. While haematopoiesis is common to all animals possessing a circulatory system, the specific mechanisms and ultimate products of haematopoietic events vary greatly. Our understanding of this process in non-vertebrate organisms is primarily derived from those species that serve as developmental and immunological models, with sparse investigations having been carried out in other organisms spanning the metazoa. As research into the regulation of immune and blood cell development advances, we have begun to gain insight into haematopoietic events in a wider array of animals, including the molluscs. What began in the early 1900’s as observational studies on the morphological characteristics of circulating immune cells has now advanced to mechanistic investigations of the cytokines, growth factors, receptors, signalling pathways, and patterns of gene expression that regulate molluscan haemocyte development. Emerging is a picture of an incredible diversity of developmental processes and outcomes that parallels the biological diversity observed within the different classes of the phylum Mollusca. However, our understanding of haematopoiesis in molluscs stems primarily from the three most-studied classes, the Gastropoda, Cephalopoda and Bivalvia. While these represent perhaps the molluscs of greatest economic and medical importance, the fact that our information is limited to only 3 of the 9 extant classes in the phylum highlights the need for further investigation in this area. In this review, we summarize the existing literature that defines haematopoiesis and its products in gastropods, cephalopods and bivalves. PMID:26592965
Pila, E A; Sullivan, J T; Wu, X Z; Fang, J; Rudko, S P; Gordy, M A; Hanington, P C
2016-05-01
Haematopoiesis is a process that is responsible for generating sufficient numbers of blood cells in the circulation and in tissues. It is central to maintenance of homeostasis within an animal, and is critical for defense against infection. While haematopoiesis is common to all animals possessing a circulatory system, the specific mechanisms and ultimate products of haematopoietic events vary greatly. Our understanding of this process in non-vertebrate organisms is primarily derived from those species that serve as developmental and immunological models, with sparse investigations having been carried out in other organisms spanning the metazoa. As research into the regulation of immune and blood cell development advances, we have begun to gain insight into haematopoietic events in a wider array of animals, including the molluscs. What began in the early 1900's as observational studies on the morphological characteristics of circulating immune cells has now advanced to mechanistic investigations of the cytokines, growth factors, receptors, signalling pathways, and patterns of gene expression that regulate molluscan haemocyte development. Emerging is a picture of an incredible diversity of developmental processes and outcomes that parallels the biological diversity observed within the different classes of the phylum Mollusca. However, our understanding of haematopoiesis in molluscs stems primarily from the three most-studied classes, the Gastropoda, Cephalopoda and Bivalvia. While these represent perhaps the molluscs of greatest economic and medical importance, the fact that our information is limited to only 3 of the 9 extant classes in the phylum highlights the need for further investigation in this area. In this review, we summarize the existing literature that defines haematopoiesis and its products in gastropods, cephalopods and bivalves. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Harutyunyan, Hayk A.; Sahakyan, Gohar V.
2016-01-01
The aim of this study was to determine activities of pro-/antioxidant enzymes, reactive oxygen species (ROS) content, and oxidative modification of proteins and lipids in red blood cells (RBCs) and blood plasma of rats exposed to electrostatic field (200 kV/m) during the short (1 h) and the long periods (6 day, 6 h daily). Short-term exposure was characterized by the increase of oxidatively damaged proteins in blood of rats. This was strongly expressed in RBC membranes. After long-term action, RBC content in peripheral blood was higher than in control ( P < 0.01) and the attenuation of prooxidant processes was shown.
Willems, Elise; Smismans, Annick; Cartuyvels, Reinoud; Coppens, Guy; Van Vaerenbergh, Kristien; Van den Abeele, Anne-Marie; Frans, Johan
2012-05-01
Bloodstream infections remain a major challenge in medicine. Optimal detection of pathogens is only possible if the quality of preanalytical factors is thoroughly controlled. Since the laboratory is responsible for this preanalytical phase, the quality control of critical factors should be integrated in its quality control program. The numerous recommendations regarding blood culture collection contain controversies. Only an unambiguous guideline permits standardization and interlaboratory quality control. We present an evidence-based concise guideline of critical preanalytical determinants for blood culture collection and summarize key performance indicators with their concomitant target values. In an attempt to benchmark, we compared the true-positive rate, contamination rate, and collected blood volume of blood culture bottles in 5 Belgian hospital laboratories. The true-positive blood culture rate fell within previously defined acceptation criteria by Baron et al. (2005) in all 5 hospitals, whereas the contamination rate exceeded the target value in 4 locations. Most unexpected, in each of the 5 laboratories, more than one third of the blood culture bottles were incorrectly filled, irrespective of the manufacturer of the blood culture vials. As a consequence of this shortcoming, one manufacturer recently developed an automatic blood volume monitoring system. In conclusion, clear recommendations for standardized blood culture collection combined with quality control of critical factors of the preanalytical phase are essential for diagnostic blood culture improvement. Copyright © 2012 Elsevier Inc. All rights reserved.
Laser doppler blood flow imaging using a CMOS imaging sensor with on-chip signal processing.
He, Diwei; Nguyen, Hoang C; Hayes-Gill, Barrie R; Zhu, Yiqun; Crowe, John A; Gill, Cally; Clough, Geraldine F; Morgan, Stephen P
2013-09-18
The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF) imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.
Balijepalli, Chakrapani; Bramlage, Peter; Lösch, Christian; Zemmrich, Claudia; Humphries, Karin H; Moebus, Susanne
2014-06-01
Contemporary epidemiological data on blood pressure readings, hypertension prevalence and control in unselected patient populations covering a broad age range are scarce. The aim here is to report the prevalence of high blood pressure and to identify factors associated with blood pressure control in a large German primary care sample. We used data from the German Metabolic and Cardiovascular Risk Study including 35 869 patients aged 18-99 years. High blood pressure was defined as systolic blood pressure ≥140 mm Hg and/or diastolic blood pressure ≥90 mm Hg or using antihypertensive therapy. Factors associated with blood pressure control among patients receiving antihypertensive therapy were examined using multiple logistic regressions to estimate odds ratios and 95% confidence intervals. The prevalence of high blood pressure, uncontrolled high blood pressure and untreated high blood pressure was 54.8%, 21.3% and 17.6%, respectively. Age >50 years (1.52; 1.40-1.65), male sex (1.30; 1.20-1.41), elevated waist circumference (1.55; 1.45-1.65), high cholesterol (1.24; 1.16-1.33), high triglycerides (1.11; 1.04-1.19) and concomitant diabetes (1.29; 1.20-1.40) were independently associated with uncontrolled high blood pressure. In a majority of patients we observed hypertension despite treatment for high blood pressures. Studies examining the reasons for treatment failure are highly warranted.
Seong, Yekyung; Lazarus, Nicole H.; Sutherland, Lusijah; Habtezion, Aida; Abramson, Tzvia; He, Xiao-Song; Greenberg, Harry B.
2017-01-01
Antibody-secreting cells are generated in regional lymphoid tissues and traffic as plasmablasts (PBs) via lymph and blood to target sites for local immunity. We used multiparameter flow cytometry to define PB trafficking programs (TPs, combinations of adhesion molecules and chemoattractant receptors) and their imprinting in patients in response to localized infection or immune insults. TPs enriched after infection or autoimmune inflammation of mucosae correlate with sites of immune response or symptoms, with different TPs imprinted during small intestinal, colon, throat, and upper respiratory immune challenge. PBs induced after intramuscular or intradermal influenza vaccination, including flu-specific antibody–secreting cells, display TPs characterized by the lack of mucosal homing receptors. PBs of healthy donors display diverse mucosa-associated TPs, consistent with homeostatic immune activity. Identification of TP signatures of PBs may facilitate noninvasive monitoring of organ-specific immune responses. PMID:28352656
Role of glycemic elements of Cynodon dactylon and Musa paradisiaca in diabetes management.
Rai, Prashant Kumar; Jaiswal, Dolly; Rai, Nilesh K; Pandhija, Shiwani; Rai, A K; Watal, Geeta
2009-09-01
The study defined the scientific evaluation of glycemic elements of extracts of Cynodon dactylon and Musa paradisiaca. A dose of 500 mg/kg body weight (bw) of C. dactylon produced maximum falls of 23.2% and 22.8% in blood glucose levels of normoglycemic rats during studies of fasting blood glucose and glucose tolerance, respectively, whereas the same dose of M. paradisiaca produced a rise of 34.9% and 18.4%. In diabetic rats during glucose tolerance tests, a fall of 27.8% and a rise of 17.5% were observed with the same dose of C. dactylon and M. paradisiaca, respectively. Laser-induced breakdown spectroscopy used for detection of glycemic elements present in both the extracts indicated that C. dactylon was rich in magnesium (Mg), whereas M. paradisiaca was rich in potassium (K) and sodium (Na), comparatively, suggesting thereby the defined roles of these elements in diabetes management.
Transfusion safety: is this the business of blood centers?
Slapak, Colleen; Fredrich, Nanci; Wagner, Jeffrey
2011-12-01
ATSO is in a unique position to break down organizational silos between hospitals and blood centers through the development of a collaborative relationship between the two entities. Use of the TSO as blood center staff centralizes the role into a consultative position thereby retaining the independence of the hospitals. The TSO position then becomes a value-added service offered by the blood center designed to supplement processes within the hospital.Whether the TSO is based in the hospital or the blood center, improvements are gained through appropriate utilization of blood components, reductions in hospital costs, ongoing education of hospital staff involved in transfusion practice, and increased availability of blood products within the community. Implementation and standardization of best practice processes for ordering and administration of blood products developed by TSOs leads to improved patient outcomes. As a liaison between hospitals and blood centers, the TSO integrates the mutual goal of transfusion safety: the provision of the safest blood product to the right patient at the right time for the right reason.
Blood Type Biochemistry and Human Disease
Ewald, D Rose; Sumner, Susan CJ
2016-01-01
Associations between blood type and disease have been studied since the early 1900s when researchers determined that antibodies and antigens are inherited. In the 1950s, the chemical identification of the carbohydrate structure of surface antigens led to the understanding of biosynthetic pathways. The blood type is defined by oligosaccharide structures, which are specific to the antigens, thus, blood group antigens are secondary gene products, while the primary gene products are various glycosyltransferase enzymes that attach the sugar molecules to the oligosaccharide chain. Blood group antigens are found on red blood cells, platelets, leukocytes, plasma proteins, certain tissues, and various cell surface enzymes, and also exist in soluble form in body secretions such as breast milk, seminal fluid, saliva, sweat, gastric secretions, urine, and amniotic fluid. Recent advances in technology, biochemistry, and genetics have clarified the functional classifications of human blood group antigens, the structure of the A, B, H, and Lewis determinants and the enzymes that produce them, and the association of blood group antigens with disease risks. Further research to identify differences in the biochemical composition of blood group antigens, and the relationship to risks for disease, can be important for the identification of targets for the development of nutritional intervention strategies, or the identification of druggable targets. PMID:27599872
Mogasale, Vittal; Ramani, Enusa; Mogasale, Vijayalaxmi V; Park, JuYeon
2016-05-17
Blood culture is often used in definitive diagnosis of typhoid fever while, bone marrow culture has a greater sensitivity and considered reference standard. The sensitivity of blood culture measured against bone marrow culture results in measurement bias because both tests are not fully sensitive. Here we propose a combination of the two cultures as a reference to define true positive S. Typhi cases. Based on a systematic literature review, we identified ten papers that had performed blood and bone marrow culture for S. Typhi in same subjects. We estimated the weighted mean of proportion of cases detected by culture measured against true S. Typhi positive cases using a random effects model. Of 529 true positive S. Typhi cases, 61 % (95 % CI 52-70 %) and 96 % (95 % CI 93-99 %) were detected by blood and bone marrow cultures respectively. Blood culture sensitivity was 66 % (95 % CI 56-75 %) when compared with bone marrow culture results. The use of blood culture sensitivity as a proxy measure to estimate the proportion of typhoid fever cases detected by blood culture is likely to be an underestimate. As blood culture sensitivity is used as a correction factor in estimating typhoid disease burden, epidemiologists and policy makers should account for the underestimation.
2012-11-01
All countries face challenges in making sufficient supplies of blood and blood products available and sustainable, while also ensuring the quality and safety of these products in the face of known and emerging threats to public health. Since 1975, the World Health Assembly (WHA) has highlighted the global need for blood safety and availability. WHA resolutions 63·12, 58·13 and 28·72, The Melbourne Declaration on 100% Voluntary Non-Remunerated Donation of Blood and Blood Components and WHO Global Blood Safety Network recommendations have reaffirmed the achievement of 'Self-sufficiency in blood and blood products based on voluntary non-remunerated blood donation (VNRBD)' as the important national policy direction for ensuring a safe, secure and sufficient supply of blood and blood products, including labile blood components and plasma-derived medicinal products. Despite some successes, self-sufficiency is not yet a reality in many countries. A consultation of experts, convened by the World Health Organization (WHO) in September 2011 in Geneva, Switzerland, addressed the urgent need to establish strategies and mechanisms for achieving self-sufficiency. Information on the current situation, and country perspectives and experiences were shared. Factors influencing the global implementation of self-sufficiency, including safety, ethics, security and sustainability of supply, trade and its potential impact on public health, availability and access for patients, were analysed to define strategies and mechanisms and provide practical guidance on achieving self-sufficiency. Experts developed a consensus statement outlining the rationale and definition of self-sufficiency in safe blood and blood products based on VNRBD and made recommendations to national health authorities and WHO. © 2012 World Health Organization. Vox Sanguinis © 2012 International Society of Blood Transfusion.
Park, M; Costa, E L V; Maciel, A T; Barbosa, E V S; Hirota, A S; Schettino, G de P; Azevedo, L C P
2014-11-01
Transmembrane pressure drop reflects the resistance of an artificial lung system to blood transit. Decreased resistance (low transmembrane pressure drop) enhances blood flow through the oxygenator, thereby, enhancing gas exchange efficiency. This study is part of a previous one where we observed the behaviour and the modulation of blood pressure drop during the passage of blood through artificial lung membranes. Before and after the induction of multi-organ dysfunction, the animals were instrumented and analysed for venous-venous extracorporeal membrane oxygenation, using a pre-defined sequence of blood flows. Blood flow and revolutions per minute (RPM) of the centrifugal pump varied in a linear fashion. At a blood flow of 5.5 L/min, pre- and post-pump blood pressures reached -120 and 450 mmHg, respectively. Transmembrane pressures showed a significant spread, particularly at blood flows above 2 L/min; over the entire range of blood flow rates, there was a positive association of pressure drop with blood flow (0.005 mmHg/mL/minute of blood flow) and a negative association of pressure drop with temperature (-4.828 mmHg/(°Celsius). These associations were similar when blood flows of below and above 2000 mL/minute were examined. During its passage through the extracorporeal system, blood is exposed to pressure variations from -120 to 450 mmHg. At high blood flows (above 2 L/min), the drop in transmembrane pressure becomes unpredictable and highly variable. Over the entire range of blood flows investigated (0-5500 mL/min), the drop in transmembrane pressure was positively associated with blood flow and negatively associated with body temperature. © The Author(s) 2014.
NASA Technical Reports Server (NTRS)
Deshpande, Arati
2004-01-01
Contributing to NASA s mission, the Microgravity Fluid Physics research program conducts experiments to promote space exploration and improvement of processes and products on Earth. One of the projects through this program deals with the affect of regulators on vascular remodeling and angiogenesis. This project is being led by Dr. Patricia Parsons-Wingerter. To perform the experiments, protein regulators are tested on the chorioallantoic membrane (CAM) of the Japanese quail embryos. The different types of regulators used can be broken down into two major groups of stimulators, and inhibitors. Stimulators increase the rate of blood vessel growth and inhibitors decrease of blood vessel growth. The specified regulator proteins include thrombospondin 1 (TSP-1) and a novel vessel tortuosity factor (TF), these are just the ones used in this specific experiment; other various protein regulators can also be used. The novel vessel tortuosity factor (TF) is a special kind of stimulator because it stimulates vessel tortuosity and curvature, rather than actual blood vessel growth. These regulators are being tested on Japanese quail embryos. The Japanese quail embryos naturally form a chorioallantoic membrane (CAM) from which blood flow, vascular remodeling, and angiogenesis can be observed. Chorioallantoic membranes are also easier to use because they are two dimensional when mounted onto a slide for examination. The analysis of the affect of the regulators on the CAM can be studied through PIVPROC; the program is used to analyze the altered blood flow in response to application of TF. Regulators are being thoroughly studied because cardiovascular alterations are the second highest, NASA-defined, risk categories in human space exploration. This research done on the quail is extending to even more projects that will be done on lab animals such as mice and also in human clinical studies like the diabetic retina. Not only will this research be beneficial to further space exploration, but it will also help life here on Earth. The higher understanding of the formation of blood vessels can also help further research in health problems such as diabetes and heart disease.
21 CFR 870.2100 - Cardiovascular blood flowmeter.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiovascular blood flowmeter. 870.2100 Section... Cardiovascular blood flowmeter. (a) Identification. A cardiovascular blood flowmeter is a device that is connected to a flow transducer that energizes the transducer and processes and displays the blood flow...
21 CFR 870.2100 - Cardiovascular blood flowmeter.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiovascular blood flowmeter. 870.2100 Section... Cardiovascular blood flowmeter. (a) Identification. A cardiovascular blood flowmeter is a device that is connected to a flow transducer that energizes the transducer and processes and displays the blood flow...
21 CFR 870.2100 - Cardiovascular blood flowmeter.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiovascular blood flowmeter. 870.2100 Section... Cardiovascular blood flowmeter. (a) Identification. A cardiovascular blood flowmeter is a device that is connected to a flow transducer that energizes the transducer and processes and displays the blood flow...
21 CFR 870.2100 - Cardiovascular blood flowmeter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiovascular blood flowmeter. 870.2100 Section... Cardiovascular blood flowmeter. (a) Identification. A cardiovascular blood flowmeter is a device that is connected to a flow transducer that energizes the transducer and processes and displays the blood flow...
Error detection and reduction in blood banking.
Motschman, T L; Moore, S B
1996-12-01
Error management plays a major role in facility process improvement efforts. By detecting and reducing errors, quality and, therefore, patient care improve. It begins with a strong organizational foundation of management attitude with clear, consistent employee direction and appropriate physical facilities. Clearly defined critical processes, critical activities, and SOPs act as the framework for operations as well as active quality monitoring. To assure that personnel can detect an report errors they must be trained in both operational duties and error management practices. Use of simulated/intentional errors and incorporation of error detection into competency assessment keeps employees practiced, confident, and diminishes fear of the unknown. Personnel can clearly see that errors are indeed used as opportunities for process improvement and not for punishment. The facility must have a clearly defined and consistently used definition for reportable errors. Reportable errors should include those errors with potentially harmful outcomes as well as those errors that are "upstream," and thus further away from the outcome. A well-written error report consists of who, what, when, where, why/how, and follow-up to the error. Before correction can occur, an investigation to determine the underlying cause of the error should be undertaken. Obviously, the best corrective action is prevention. Correction can occur at five different levels; however, only three of these levels are directed at prevention. Prevention requires a method to collect and analyze data concerning errors. In the authors' facility a functional error classification method and a quality system-based classification have been useful. An active method to search for problems uncovers them further upstream, before they can have disastrous outcomes. In the continual quest for improving processes, an error management program is itself a process that needs improvement, and we must strive to always close the circle of quality assurance. Ultimately, the goal of better patient care will be the reward.
Definition and documentation of engineering processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, G.W.
1997-11-01
This tutorial is an extract of a two-day workshop developed under the auspices of the Quality Engineering Department at Sandia National Laboratories. The presentation starts with basic definitions and addresses why processes should be defined and documented. It covers three primary topics: (1) process considerations and rationale, (2) approach to defining and documenting engineering processes, and (3) an IDEFO model of the process for defining engineering processes.
Childhood obesity affects adult metabolic syndrome and diabetes.
Liang, Yajun; Hou, Dongqing; Zhao, Xiaoyuan; Wang, Liang; Hu, Yuehua; Liu, Junting; Cheng, Hong; Yang, Ping; Shan, Xinying; Yan, Yinkun; Cruickshank, J Kennedy; Mi, Jie
2015-09-01
We seek to observe the association between childhood obesity by different measures and adult obesity, metabolic syndrome (MetS), and diabetes. Thousand two hundred and nine subjects from "Beijing Blood Pressure Cohort Study" were followed 22.9 ± 0.5 years in average from childhood to adulthood. We defined childhood obesity using body mass index (BMI) or left subscapular skinfold (LSSF), and adult obesity as BMI ≥ 28 kg/m(2). MetS was defined according to the joint statement of International Diabetes Federation and American Heart Association with modified waist circumference (≥ 90/85 cm for men/women). Diabetes was defined as fasting plasma glucose ≥ 7.0 mmol/L or blood glucose 2 h after oral glucose tolerance test ≥ 11.1 mmol/L or currently using blood glucose-lowering agents. Multiple linear and logistic regression models were used to assess the association. The incidence of adult obesity was 13.4, 60.0, 48.3, and 65.1 % for children without obesity, having obesity by BMI only, by LSSF only, and by both, respectively. Compared to children without obesity, children obese by LSSF only or by both had higher risk of diabetes. After controlling for adult obesity, childhood obesity predicted independently long-term risks of diabetes (odds ratio 2.8, 95 % confidence interval 1.2-6.3) or abdominal obesity (2.7, 1.6-4.7) other than MetS as a whole (1.2, 0.6-2.4). Childhood obesity predicts long-term risk of adult diabetes, and the effect is independent of adult obesity. LSSF is better than BMI in predicting adult diabetes.
Aloe vera: a systematic review of its clinical effectiveness.
Vogler, B K; Ernst, E
1999-01-01
BACKGROUND: The use of aloe vera is being promoted for a large variety of conditions. Often general practitioners seem to know less than their patients about its alleged benefits. AIM: To define the clinical effectiveness of aloe vera, a popular herbal remedy in the United Kingdom. METHOD: Four independent literature searches were conducted in MEDLINE, EMBASE, Biosis, and the Cochrane Library. Only controlled clinical trials (on any indication) were included. There were no restrictions on the language of publication. All trials were read by both authors and data were extracted in a standardized, pre-defined manner. RESULTS: Ten studies were located. They suggest that oral administration of aloe vera might be a useful adjunct for lowering blood glucose in diabetic patients as well as for reducing blood lipid levels in patients with hyperlipidaemia. Topical application of aloe vera is not an effective preventative for radiation-induced injuries. It might be effective for genital herpes and psoriasis. Whether it promotes wound healing is unclear. There are major caveats associated with all of these statements. CONCLUSION: Even though there are some promising results, clinical effectiveness of oral or topical aloe vera is not sufficiently defined at present. PMID:10885091
Leyva-Cobián, F; Outschoorn, I M; Carrasco-Marín, E; Alvarez-Domínguez, C
1997-10-01
Intracellular pathogens can be considered as particulate antigens chemically composed of a complex mixture of T-cell-dependent antigens (TD) (peptides and proteins) and T-cell-independent antigens (TI) (glycolipids and complex polysaccharides). A large range of saccharides (from oligosaccharides to complex polysaccharides) derived from pathogenic microorganisms are being isolated and characterized. They are currently implicated in signaling systems and concomitant host-parasite relationships. However, there are not many structure-function relationships described for these pathogens. This is particularly true of polysaccharides. In this report we have reviewed the role of defined TI antigens in the processing and presentation of defined TD antigens to specific T cells by antigen-presenting cells (APC). We also considered the importance of some of the chemical characteristics shared by different carbohydrates implicated in the inhibition of antigen presentation. These findings are discussed in relation to the clear immunopathological consequences of long retention periods of complex carbohydrate molecules derived from intracellular parasites inside certain APC and the absence of antigen presentation impairment in physiological situations such as the removal of senescent or damaged red blood cells by splenic macrophages or intracellular accumulation of carbohydrates in colostrum and milk macrophages during lactation.
[Concept Analysis for Psychological Insulin Resistance in Korean People with Diabetes].
Song, Youngshin
2016-06-01
The purpose of this study was to define the concept for psychological insulin resistance in the Korean population with diabetes. The Hybrid model was used to perform the concept analysis of psychological insulin resistance. Results from both the theoretical review with 26 studies and a field study including 19 participants with diabetes were included in final process. The preceding factors of psychological insulin resistance were uncontrolled blood glucose and change in daily life. The concept of psychological insulin resistance was found to have three categories with 8 attributes such as emotional factors (negative feeling), cognitive factors (low awareness and knowledge, low confidence for self-injection) and supportive factors (economic burden, dependency life, embarrassing, feeling about supporters, feeling of trust in, vs mistrust of health care providers). The 8 attributes included 30 indicators. The psychological insulin resistance of population with diabetes in Korea was defined as a complex phenomenon associated with insulin therapy that can be affected by emotional factors, cognitive factors, and supportive relational factors. Based on the results, a tool for measuring psychological insulin resistance of Koreans with diabetes and effective programs for enhancing insulin adherence should be developed in future studies.
Ruffato, Marco; Novello, Lorenzo; Clark, Louise
2015-01-01
Determine arterial blood pressure range that diplomates of the American College of Veterinary Anesthesia and Analgesia (ACVAA) and European College of Veterinary Anaesthesia and Analgesia (ECVAA) use to define intraoperative hypotension in dogs and identify the threshold values used for intervention. Survey of veterinary anesthesia specialists. Diplomates of the ACVAA and ECVAA. ACVAA and ECVAA diplomates (n = 313) were invited to participate in an Internet-based survey regarding anesthetized healthy dogs undergoing two types of procedures (diagnostic or surgical). There were 151 respondents to the survey; 70.2% were ACVAA diplomates and 29.8% were ECVAA diplomates. The majority of the respondents (70.9%) worked in academia while the others were in private practice (19.2%), or research, diagnostic or pharmaceutical fields (9.9%). Hypotension was defined (mean ± SD) by the respondents as systolic arterial blood pressure (SAP) <87 ± 8 mmHg for surgical cases and <87 ± 6 mmHg for diagnostic cases, or mean arterial pressure (MAP) <62 ± 4 mmHg for both types of cases. Arterial pressures reported to prompt treatment were SAP 85 ± 13 mmHg or MAP 61 ± 4 mmHg in surgical cases, and SAP 84 ± 11 mmHg or MAP 63 ± 8 mmHg in diagnostic cases. There was agreement between ACVAA and ECVAA diplomates on the definition of intraoperative hypotension in dogs during anesthesia. The blood pressures used to define hypotension were similar to the pressures that would prompt diplomates to start treatment. Readers could infer that diplomates define hypotension as a clinical condition that requires treatment at the time of diagnosis. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Kalina, Tomas; Flores-Montero, Juan; Lecrevisse, Quentin; Pedreira, Carlos E; van der Velden, Vincent H J; Novakova, Michaela; Mejstrikova, Ester; Hrusak, Ondrej; Böttcher, Sebastian; Karsch, Dennis; Sędek, Łukasz; Trinquand, Amelie; Boeckx, Nancy; Caetano, Joana; Asnafi, Vahid; Lucio, Paulo; Lima, Margarida; Helena Santos, Ana; Bonaccorso, Paola; van der Sluijs-Gelling, Alita J; Langerak, Anton W; Martin-Ayuso, Marta; Szczepański, Tomasz; van Dongen, Jacques J M; Orfao, Alberto
2015-02-01
Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry. © 2014 International Society for Advancement of Cytometry.
Ultrasonic processing for recovery of chicken erythrocyte hemoglobin
USDA-ARS?s Scientific Manuscript database
Hemoglobin from chicken blood has been shown to be a good substitute for synthetic polymeric flocculants. One stage of processing the blood entails breaking open the cells and releasing the cytoplasmic contents; in the present study, we investigate the use of ultrasonic processing at this stage. Was...
ASSOCIATION OF DAIRY CONSUMPTION AND 24-HOUR BLOOD PRESSURE IN OLDER ADULTS WITH HYPERTENSION.
Lana, Alberto; Banegas, Jose R; Guallar-Castillón, Pilar; Rodríguez-Artalejo, Fernando; Lopez-Garcia, Esther
2018-05-25
The aim was to examine the association between habitual consumption of dairy products and 24-h ambulatory blood pressure monitoring among older adults with hypertension. We conducted an analysis of 715 community-living hypertensive adults aged ≥60. Habitual dairy consumption was assessed with a validated diet history. Blood pressure was recorded by 24-hour ambulatory blood pressure monitoring; controlled blood pressure was defined as 24-hour blood pressure <130/80 mm Hg in those under drug treatment. Analyses were adjusted for main confounders, including diet, hypertension duration, and being on antihypertensive treatment. After adjustment for confounders, consumers of ≥7 servings/wk of whole milk/yogurt had a diastolic blood pressure 1.40 mm Hg higher (95% confidence interval: 0.01, 2.81) than consumers of <1 serving/wk. By contrast, consumers of ≥7 servings/wk of low-fat milk/yogurt had a diastolic blood pressure 1.74 mm Hg lower (95% confidence interval: -3.26, -0.23) than consumers of <1 serving/wk. Moreover, the odds ratio (95% confidence interval) for controlled blood pressure was 1.83 (1.05-3.08) for those consuming ≥7 servings/wk of low-fat milk/yogurt, when comparing with consumers of <1 serving/wk. Cheese consumption was not associated with blood pressure. Regular consumption of low-fat milk/yogurt was associated with lower 24-h diastolic blood pressure and with better blood pressure control among older adults with hypertension. Copyright © 2018. Published by Elsevier Inc.
Traffic safety facts 1998 : alcohol
DOT National Transportation Integrated Search
1999-01-01
The National Highway Traffic Safety Administration (NHTSA) defines a fatal traffic crash as being alcohol-related if either a driver or a nonoccupant (e.g., pedestrian) had a blood alcohol concentration (BAC) of 0.01 grams per deciliter (g/dl) or gre...
Traffic safety facts 1995 : alcohol
DOT National Transportation Integrated Search
1995-01-01
The National Highway Traffic Safety Administration (NHTSA) defines a fatal traffic crash as being alcohol-related if either a driver or a nonoccupant (e.g., pedestrian) had a blood alcohol concentration (BAC) of 0.01 grams per deciliter (g/dl) or gre...
Traffic safety facts 1993 : alcohol
DOT National Transportation Integrated Search
1994-01-01
The National Highway Traffic Safety Administration (NHTSA) defines a fatal traffic crash as being alcohol-related if either a driver or a nonoccupant (e.g., pedestrian) had a blood alcohol concentration (BAC) of 0.01 grams per deciliter (g/dl) or gre...
Traffic safety facts 2000 : alcohol
DOT National Transportation Integrated Search
2001-01-01
The National Highway Traffic Safety Administration (NHTSA) defines a fatal traffic crash as being alcohol-related if either a driver or a nonoccupant (e.g., pedestrian) had a blood alcohol concentration (BAC) of 0.01 grams per deciliter (g/dl) or gre...
Traffic safety facts 1994 : alcohol
DOT National Transportation Integrated Search
1994-01-01
The National Highway Traffic Safety Administration (NHTSA) defines a fatal traffic crash as being alcohol-related if either a driver or a nonoccupant (e.g., pedestrian) had a blood alcohol concentration (BAC) of 0.01 grams per deciliter (g/dl) or gre...
Traffic safety facts 1999 : alcohol
DOT National Transportation Integrated Search
2000-01-01
The National Highway Traffic Safety Administration (NHTSA) defines a fatal traffic crash as being alcohol-related if either a driver or a nonoccupant (e.g., pedestrian) had a blood alcohol concentration (BAC) of 0.01 grams per deciliter (g/dl) or gre...
Identifying mechanistic indicators of childhood asthma from blood gene expression
Asthmatic individuals have been identified as a susceptible subpopulation for air pollutants. However, asthma represents a syndrome with multiple probable etiologies, and the identification of these asthma endotypes is critical to accurately define the most susceptible subpopula...
Yagi, Satomi; Koh, Yasuhiro; Akamatsu, Hiroaki; Kanai, Kuninobu; Hayata, Atsushi; Tokudome, Nahomi; Akamatsu, Keiichiro; Endo, Katsuya; Nakamura, Seita; Higuchi, Masayuki; Kanbara, Hisashige; Nakanishi, Masanori; Ueda, Hiroki; Yamamoto, Nobuyuki
2017-01-01
Circulating tumor cells (CTCs), defined as tumor cells circulating in the peripheral blood of patients with solid tumors, are relatively rare. Diagnosis using CTCs is expected to help in the decision-making for precision cancer medicine. We have developed an automated microcavity array (MCA) system to detect CTCs based on the differences in size and deformability between tumor cells and normal blood cells. Herein, we evaluated the system using blood samples from non-small-cell lung cancer (NSCLC) and small-cell lung cancer (SCLC) patients. To evaluate the recovery of CTCs, preclinical experiments were performed by spiking NSCLC cell lines (NCI-H820, A549, NCI-H23 and NCI-H441) into peripheral whole blood samples from healthy volunteers. The recovery rates were 70% or more in all cell lines. For clinical evaluation, 6 mL of peripheral blood was collected from 50 patients with advanced lung cancer and from 10 healthy donors. Cells recovered on the filter were stained. We defined CTCs as DAPI-positive, cytokeratin-positive, and CD45-negative cells under the fluorescence microscope. The 50 lung cancer patients had a median age of 72 years (range, 48-85 years); 76% had NSCLC and 20% had SCLC, and 14% were at stage III disease whereas 86% were at stage IV. One or more CTCs were detected in 80% of the lung cancer patients (median 2.5). A comparison of the CellSearch system with our MCA system, using the samples from NSCLC patients, confirmed the superiority of our system (median CTC count, 0 versus 11 for CellSearch versus MCA; p = 0.0001, n = 17). The study results suggest that our MCA system has good clinical potential for diagnosing CTCs in lung cancer.
Pluskwa, F; Bonnet, F; Abhay, K; Touboul, C; Rey, B; Marcandoro, J; Becquemin, J B
1989-01-01
A study was carried out to compare the evolution of arterial blood pressure during carotid endarterectomy performed under either general anaesthesia (GA) or cervical epidural anaesthesia (CEA). 20 patients were randomly assigned to two equal groups. In the CEA group, 15 ml of 0.375% bupivacaine and 150 micrograms fentanyl were injected into the epidural space at C7-D1 level. In the GA group, patients were anaesthetized with 0.2 mg.kg-1 flunitrazepam and 5 micrograms.kg-1 fentanyl; intubation was carried out using 0.08 mg.kg-1 vecuronium, and the patients were ventilated with a mixture of nitrous oxide and oxygen (50% of each). Further injections, every 30 min, of 2 micrograms.kg-1 fentanyl were given to the patients in group GA. Blood pressure was monitored continuously, up to 4 h postoperatively, with a radial arterial catheter. Per- or postoperative hypertension was defined as a rise in systolic arterial blood pressure (Pasys) over 180 mmHg for greater than 3 min; this was treated with 20 mg nifedipine intranasally (group CEA) or 100 micrograms fentanyl with 0.5 mg flunitrazepam with or without nifedipine (group GA). Per- or postoperative hypotension was defined as a fall in Pasys below 100 mmHg and or a 30% fall in mean arterial blood pressure for greater than 3 min; this was treated, in both groups, with an intravenous bolus of 3 mg ephedrine. Patients in group CEA experienced more frequent episodes of peroperative hypertension (8/2; p less than 0.02) and postoperative hypotension (5/1) than group GA.(ABSTRACT TRUNCATED AT 250 WORDS)
Bapodra, Priya; Cracknell, Jonathan; Wolfe, Barbara A
2014-03-01
Three adult and two subadult greater one-horned rhinoceroses (Rhinoceros unicornis) were sedated a total of nine times using two different intramuscular sedative combinations in order to compare the effectiveness of these combinations in inducing consistent standing sedation in this species. The sedation protocols compared were butorphanol tartrate (50-60 mg) and detomidine hydrochloride (20-30 mg; BD) versus butorphanol tartrate (80-120 mg) and azaperone (80-120 mg; BA). Specific doses were adjusted according to age and sex class, and based on previous experience. Parameters compared included time to achieve defined levels of sedation, time to recovery following antagonism, physiological parameters including heart rate, respiratory rate, indirect arterial blood pressure, and venous blood gas values. A hydraulic restraint chute was utilized to mechanically restrain animals during the procedures, and blood collection and ophthalmic examinations were conducted on all animals. Both protocols resulted in standing sedation for > or = 22.3 +/- 2.9 min or until antagonists were administered. The BD protocol resulted in deeper and more consistent sedation, compared to the BA protocol. Naltrexone hydrochloride (250-300 mg) and tolazoline hydrochloride (1,500-2,000 mg) were administered intramuscularly to antagonize protocol BD, whereas naltrexone alone (200-500 mg) was used to antagonize BA. Time to full antagonism, defined as normal mentation and ambulation following administration of antagonists, was prolonged in the BD protocol (132.3 +/- 17.2 min) compared with the BA protocol (7.5 +/- 2.5 min). Venous blood gas analysis did not reveal any significant blood gas deviations during sedation when compared with either conscious equine or white rhinoceros (Ceratotherium simum) venous reference ranges. In summary, both combinations resulted in adequate standing sedation for minimally invasive procedures, although BD resulted in more profound and consistent sedation.
Kiss, Joseph E; Steele, Whitney R; Wright, David J; Mast, Alan E; Carey, Patricia M; Murphy, Edward L; Gottschall, Jerry L; Simon, Toby L; Cable, Ritchard G
2013-11-01
Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management. A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study-II (REDS-II) Donor Iron Status Evaluation (RISE) study who were either first-time/reactivated (FT/RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 μg/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron-deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE. HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 μg/L was a good surrogate for assessing IDE. RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency. © 2013 American Association of Blood Banks.
Yan, Zhongrui; Liang, Yajun; Jiang, Hui; Cai, Chuanzhu; Sun, Binglun; Qiu, Chengxuan
2014-06-01
The relationship between the metabolic syndrome and subclinical atherosclerosis among elderly people remains controversial. We seek to investigate the associations of metabolic syndrome and its components with subclinical carotid atherosclerosis in older people living in rural China. This cross-sectional study included 911 participants (age ≥60 years, 59.4% women) of the community-based Confucius Hometown Aging Project in Shandong, China, who were free of clinical cardiovascular disease. In 2010-2011, data were collected through interviews, clinical examinations, and laboratory tests. Carotid intima media thickness (cIMT) and carotid artery plaque were assessed using ultrasonography. Metabolic syndrome was defined by four sets of criteria. Data were analyzed with multiple general linear and logistic regression models. Carotid plaque was detected in 514 (56.4%) persons. Depending on the defining criteria, prevalence of metabolic syndrome ranged from 30.6% to 56.9%. Hypertension, elevated blood pressure (≥130/85 mmHg), diabetes/prediabetes, and high fasting plasma glucose (≥5.6 mmol/L) were significantly associated with an increased likelihood of carotid plaque, whereas an increased cIMT was associated with elevated blood pressure and hypertension (P<0.05). Obesity, high triglycerides, and dyslipidemia were not associated with carotid artery plaque or cIMT. The significant association of metabolic syndrome with an increased likelihood of carotid plaque disappeared when elevated blood pressure and high plasma glucose were added to the models. Metabolic syndrome was not associated with cIMT. Metabolic syndrome is associated with subclinical carotid plaque among Chinese elderly people, driven primarily by elevated blood pressure and hyperglycemia. Older adults with metabolic syndrome, especially those with high blood pressure and hyperglycemia, may benefit from evaluation for subclinical atherosclerosis.
Automated particle identification through regression analysis of size, shape and colour
NASA Astrophysics Data System (ADS)
Rodriguez Luna, J. C.; Cooper, J. M.; Neale, S. L.
2016-04-01
Rapid point of care diagnostic tests and tests to provide therapeutic information are now available for a range of specific conditions from the measurement of blood glucose levels for diabetes to card agglutination tests for parasitic infections. Due to a lack of specificity these test are often then backed up by more conventional lab based diagnostic methods for example a card agglutination test may be carried out for a suspected parasitic infection in the field and if positive a blood sample can then be sent to a lab for confirmation. The eventual diagnosis is often achieved by microscopic examination of the sample. In this paper we propose a computerized vision system for aiding in the diagnostic process; this system used a novel particle recognition algorithm to improve specificity and speed during the diagnostic process. We will show the detection and classification of different types of cells in a diluted blood sample using regression analysis of their size, shape and colour. The first step is to define the objects to be tracked by a Gaussian Mixture Model for background subtraction and binary opening and closing for noise suppression. After subtracting the objects of interest from the background the next challenge is to predict if a given object belongs to a certain category or not. This is a classification problem, and the output of the algorithm is a Boolean value (true/false). As such the computer program should be able to "predict" with reasonable level of confidence if a given particle belongs to the kind we are looking for or not. We show the use of a binary logistic regression analysis with three continuous predictors: size, shape and color histogram. The results suggest this variables could be very useful in a logistic regression equation as they proved to have a relatively high predictive value on their own.
Decoupling the effect of shear stress and stretch on tissue growth & remodeling in a vascular graft.
van Haaften, Eline E; Wissing, Tamar B; Rutten, Marcel; Bulsink, Jurgen A; Gashi, Kujtim; van Kelle, Mathieu A J; Smits, Anthal; Bouten, Carlijn; Kurniawan, Nicholas A
2018-06-07
The success of cardiovascular tissue engineering strategies largely depends on the mechanical environment in which cells develop a neo-tissue via growth and remodeling processes. This mechanical environment is defined by the local scaffold architecture to which cells adhere, i.e., the micro-environment, and by external mechanical cues to which cells respond, i.e., hemodynamic loading. The hemodynamic environment of early-developing blood vessels consists of both shear stress (due to blood flow) and circumferential stretch (due to blood pressure). Experimental platforms that recapitulate this mechanical environment in a controlled and tunable manner are thus critical for investigating cardiovascular tissue engineering. In traditional perfusion bioreactors, however, shear stress and stretch are coupled, hampering a clear delineation of their effects on cell and tissue response. Here, we uniquely designed a bioreactor that independently combines these two types of mechanical cues in eight parallel vascular grafts. The system is computationally and experimentally validated, through finite element analysis and culture of tissue constructs respectively, to distinguish various levels of shear stress (up to 5 Pa) and cyclic stretch (up to 1.10). To illustrate the usefulness of the system, we investigated the relative contribution of cyclic stretch (1.05 at 0.5 Hz) and shear stress (1 Pa) to tissue development. Both types of hemodynamic loading contributed to cell alignment, but the contribution of shear stress overruled stretch-induced cell proliferation and matrix (i.e., collagen and glycosaminoglycan) production. At a macroscopic level, cyclic stretching led to the most linear stress-stretch response, which was not related to the presence of shear stress. In conclusion, we have developed a bioreactor that is particularly suited to further unravel the interplay between hemodynamics and in situ tissue engineering processes. Using the new system, the present work highlights the importance of hemodynamic loading to the study of developing vascular tissues.
... to donate. All medical equipment used for this test, as well as during the donation process, is sterile, used only once and then disposed. Blood Donation Once the pre-donation screening is finished, you will proceed to ...
Quality Assessment of Established and Emerging Blood Components for Transfusion
Marks, Denese C.
2016-01-01
Blood is donated either as whole blood, with subsequent component processing, or through the use of apheresis devices that extract one or more components and return the rest of the donation to the donor. Blood component therapy supplanted whole blood transfusion in industrialized countries in the middle of the twentieth century and remains the standard of care for the majority of patients receiving a transfusion. Traditionally, blood has been processed into three main blood products: red blood cell concentrates; platelet concentrates; and transfusable plasma. Ensuring that these products are of high quality and that they deliver their intended benefits to patients throughout their shelf-life is a complex task. Further complexity has been added with the development of products stored under nonstandard conditions or subjected to additional manufacturing steps (e.g., cryopreserved platelets, irradiated red cells, and lyophilized plasma). Here we review established and emerging methodologies for assessing blood product quality and address controversies and uncertainties in this thriving and active field of investigation. PMID:28070448
Angelopoulos, Theodore J; Lowndes, Joshua; Sinnett, Stephanie; Rippe, James M
2015-02-01
The impact of fructose, commonly consumed with sugars by humans, on blood pressure and uric acid has yet to be defined. A total of 267 weight-stable participants drank sugar-sweetened milk every day for 10 weeks as part of their usual, mixed-nutrient diet. Groups 1 and 2 had 9% estimated caloric intake from fructose or glucose, respectively, added to milk. Groups 3 and 4 had 18% of estimated caloric intake from high fructose corn syrup or sucrose, respectively, added to the milk. Blood pressure and uric acid were determined prior to and after the 10-week intervention. There was no effect of sugar type on either blood pressure or uric acid (interaction P>.05), and a significant time effect for blood pressure was noted (P<.05). The authors conclude that 10 weeks of consumption of fructose at the 50th percentile level, whether consumed as pure fructose or with fructose-glucose-containing sugars, does not promote hyperuricemia or increase blood pressure. © 2014 Wiley Periodicals, Inc.
Diversity and divergence of the glioma-infiltrating T-cell receptor repertoire
Sims, Jennifer S.; Grinshpun, Boris; Feng, Yaping; Ung, Timothy H.; Neira, Justin A.; Samanamud, Jorge L.; Canoll, Peter; Shen, Yufeng; Sims, Peter A.; Bruce, Jeffrey N.
2016-01-01
Although immune signaling has emerged as a defining feature of the glioma microenvironment, how the underlying structure of the glioma-infiltrating T-cell population differs from that of the blood from which it originates has been difficult to measure directly in patients. High-throughput sequencing of T-cell receptor (TCR) repertoires (TCRseq) provides a population-wide statistical description of how T cells respond to disease. We have defined immunophenotypes of whole repertoires based on TCRseq of the α- and β-chains from glioma tissue, nonneoplastic brain tissue, and peripheral blood from patients. Using information theory, we partitioned the diversity of these TCR repertoires into that from the distribution of VJ cassette combinations and diversity due to VJ-independent factors, such as selection due to antigen binding. Tumor-infiltrating lymphocytes (TILs) possessed higher VJ-independent diversity than nonneoplastic tissue, stratifying patients according to tumor grade. We found that the VJ-independent components of tumor-associated repertoires diverge more from their corresponding peripheral repertoires than T-cell populations in nonneoplastic brain tissue, particularly for low-grade gliomas. Finally, we identified a “signature” set of TCRs whose use in peripheral blood is associated with patients exhibiting low TIL divergence and is depleted in patients with highly divergent TIL repertoires. This signature is detectable in peripheral blood, and therefore accessible noninvasively. We anticipate that these immunophenotypes will be foundational to monitoring and predicting response to antiglioma vaccines and immunotherapy. PMID:27261081
Eichhorn, Stefan; Spindler, Johannes; Polski, Marcin; Mendoza, Alejandro; Schreiber, Ulrich; Heller, Michael; Deutsch, Marcus Andre; Braun, Christian; Lange, Rüdiger; Krane, Markus
2017-05-01
Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR efficacy. Based on thoracic stiffness data measured in human cadavers, such a model was constructed using valve-controlled pneumatic pistons and an artificial heart. This model offers two realistic levels of chest elasticity, with a blood flow apparatus that reflects compressive depth and waveform changes. We conducted CPR at opposing levels of physiologic stiffness, using a LUCAS device, a motor-driven plunger, and a group of volunteers. In high-stiffness mode, blood flow generated by volunteers was significantly less after just 2min of CPR, whereas flow generated by LUCAS device was superior by comparison. Optimal blood flow was obtained via motor-driven plunger, with trapezoidal waveform. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Some blood chemistry values for the juvenile coho salmon (Oncorhynchus kisutch)
Wedemeyer, Gary; Chatterton, K.
1971-01-01
Overlapping Gaussian distribution curves were resolved into normal ranges for 1800 clinical test values obtained from caudal arterial blood or plasma of more than 1000 juvenile coho salmon (Oncorhynchus kisutch) held under defined conditions of diet and temperature. Estimated normal blood chemistry ranges were bicarbonate, 9.5–12.6 mEq/liter; blood urea nitrogen (BUN), 0.9–3.4 mg/100 ml; chloride, 122–136 mEq/liter; cholesterol, 88–262 mg/100 ml;pCO2, 2.6–6.1 mm Hg (10 C); glucose, 41–135 mg/100 ml; hematocrit, 32.5–52.5%; hemoglobin, 6.5–9.9 g/100 ml; total protein, 1.4–4.3 g/100 ml; blood pH (10 C), 7.51–7.83. The calculated range of normal acid–base balance vs. water temperature is also presented.
Katz, Louis M; Donnelly, John J; Gresens, Christopher J; Holmberg, Jerry A; MacPherson, James; Zacharias, Peter J K; Stanley, Jean; Bales, Christine
2018-05-01
On March 24, 2017, more than 90 experts in blood safety and international development from blood centers, industry, government, and international and nongovernmental organizations gathered in Arlington, Virginia, for the Third International Blood Safety Forum, cosponsored by America's Blood Centers and Global Healing. This report summarizes presentations and major conclusions. The meeting explored ways to increase access to affordable, safe blood for low- and lower-middle-income countries (LMICs) in an era when funding from the US President's Emergency Plan for AIDS Relief (PEPFAR) and the Global Fund has been redirected from preventing the spread of human immunodeficiency virus (HIV) to diagnosing and treating the 25 million-plus people living with HIV in LMICs. More effective management systems must be developed to improve cost recovery for blood. While blood systems become more sustainable, continued investment is required to keep them operating. The traditional model of large grants from bilateral and multilateral donors will need to be supplemented (or replaced) with public-private partnerships and nongovernmental investment. A continued emphasis on quality is fundamental. Blood systems must build quality programs, based on accepted standards, including hospitals, clinics, and rural health care providers to ensure proper and safe use of blood. Proposals to resolve health care inequities between LMICs and high-income countries (HICs) must include helping LMICs to define sustainable national policies and practices for blood availability and utilization to suit local contexts. The blood safety lexicon should be revised to include availability, accessibility, and affordability of safe blood and blood products as the goal of all blood safety initiatives. © 2018 AABB.
The effects of blood and blood products on the arachnoid cell.
Hansen, Eric A; Romanova, Liudmila; Janson, Christopher; Lam, Cornelius H
2017-06-01
After traumatic brain injury (TBI), large amounts of red blood cells and hemolytic products are deposited intracranially creating debris in the cerebrospinal fluid (CSF). This debris, which includes heme and bilirubin, is cleared via the arachnoid granulations and lymphatic systems. However, the mechanisms by which erythrocytes and their breakdown products interfere with normal CSF dynamics remain poorly defined. The purpose of this study was to model in vitro how blood breakdown products affect arachnoid cells at the CSF-blood barrier, and the extent to which the resorption of CSF into the venous drainage system is mechanically impaired following TBI. Arachnoid cells were grown to confluency on permeable membranes. Rates of growth and apoptosis were measured in the presence of blood and lysed blood, changes in transepithelial electrical resistance (TEER) was measured in the presence of blood and hemoglobin, and small molecule permeability was determined in the presence of blood, lysed blood, bilirubin, and biliverdin. These results were directly compared with an established rat brain endothelial cell line (RBEC4) co-cultured with rat brain astrocytes. We found that arachnoid cells grown in the presence of whole or lysed erythrocytes had significantly slower growth rates than controls. Bilirubin and biliverdin, despite their low solubilities, altered the paracellular transport of arachnoid cells more than the acute blood breakdown components of whole and lysed blood. Mannitol permeability was up to four times higher in biliverdin treatments than controls, and arachnoid membranes demonstrated significantly decreased small molecule permeabilities in the presence of whole and lysed blood. We conclude that short-term (<24 h) arachnoid cell transport and long-term (>5 days) arachnoid cell viability are affected by blood and blood breakdown products, with important consequences for CSF flow and blood clearance after TBI.
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, Ksenia; Nichols, James H.
2009-01-01
Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy, anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results. PMID:20144348
The prevalence of erectile dysfunction among hypertensive and prehypertensive men aged 25-40 years.
Heruti, Rafi J; Sharabi, Yehonatan; Arbel, Yaron; Shochat, Tzipi; Swartzon, Michael; Brenner, Galit; Justo, Dan
2007-05-01
Erectile dysfunction (ED) and hypertension (HTN) are common and associated among men aged 40-70 years. Data on the prevalence of ED among younger hypertensive and prehypertensive men are limited. To study the prevalence of ED in a large-scale population of hypertensive and prehypertensive men aged 25-40 years. ED severity, systolic blood pressures (SBPs), diastolic blood pressures (DBPs), and mean arterial blood pressures (MAPs). Israel Defense Force personnel, aged 25 years and older, go through routine health checks at the Staff Periodic Health Examination Center (SPEC) every 3-5 years, including measuring blood pressure and completing the Sexual Health Inventory for Men (SHIM) questionnaire in order to detect HTN and ED, respectively, and assess its severity. Pre-HTN was defined as SBP 120-139 mm Hg or DBP 80-89 mm Hg. HTN was defined as SBP >/or140 mm Hg and/or DBP >or=90 mm Hg. During 2001-2004, an overall of 11,252 men, aged 25-40 years, reported to the SPEC, and 5,860 (52.1%) men filled out the SHIM questionnaire. Among responders to the SHIM questionnaire, 1,278 (21.8%) men had low scores (
Calès, Paul; Boursier, Jérôme; Chaigneau, Julien; Lainé, Fabrice; Sandrini, Jeremy; Michalak, Sophie; Hubert, Isabelle; Dib, Nina; Oberti, Frédéric; Bertrais, Sandrine; Hunault, Gilles; Cavaro-Ménard, Christine; Gallois, Yves; Deugnier, Yves; Rousselet, Marie C
2010-10-01
Our aim was to develop an accurate, non-invasive, blood-test-based method for identifying the main characteristics of liver fibrosis in non-alcoholic fatty liver disease (NAFLD). Fibrosis was staged according to NASH-CRN and Metavir systems in 226 patients with NAFLD. A fully automated algorithm measured the fractal dimension (FD) and the area of fibrosis (AOF). Independent predictors of diagnostic targets were determined using bootstrap methods. (i) Development. Significant fibrosis defined by NASH-CRN F ≥2 was diagnosed by weight, glycaemia, aspartate aminotransferase (AST), alanine aminotransferase (ALT) and prothrombin index [area under the receiver operating characteristic (AUROC)=0.867]; significant fibrosis defined by Metavir F ≥2 was diagnosed by weight, age, glycaemia, AST, ALT, ferritin and platelets (FibroMeter AUROC=0.941, P<0.005). AOF was estimated by the combination of hyaluronic acid, glycaemia, AST, ALT, platelets and prothrombin index ((a) R(2) =0.530), while FD was estimated by hyaluronic acid, glycaemia, AST/ALT, weight and platelets ((a) R(2) =0.529). (ii) Evaluation. Although NASH-CRN was a better system for fibrosis staging, Metavir staging was a better reference for blood test. Thus, the patient rate with predictive values ≥90% by tests was 97.3% with Metavir reference vs. 66.5% with NASH-CRN reference (P<10(-3)). FibroMeter showed a significantly higher AUROC than the NAFLD fibrosis score for significant fibrosis, but not for severe fibrosis or cirrhosis, with both staging systems. Relationships between fibrosis lesions were well reflected by blood tests, e.g., the correlation between histological area and FD of fibrosis (r(s) =0.971, P<10(-3)) was well reflected by the relationship between respective blood tests (r(s) =0.852, P<10(-3)). Different characteristics of fibrosis in NAFLD can be diagnosed and quantified by blood tests with excellent accuracy. © 2010 John Wiley & Sons A/S.
Hill, C J; Cardwell, C R; Patterson, C C; Maxwell, A P; Magee, G M; Young, R J; Matthews, B; O'Donoghue, D J; Fogarty, D G
2014-04-01
We investigated the prevalence of chronic kidney disease and attainment of therapeutic targets for HbA1c and blood pressure in a large U.K.-based diabetes population. The U.K. National Diabetes Audit provided data from 1 January 2007 to 31 March 2008. Inclusion criteria were a documented urinary albumin:creatinine ratio and serum creatinine. Patients were stratified according to chronic kidney disease stage and albuminuria status. Chronic kidney disease was defined as an estimated glomerular filtration rate < 60 ml min(-1) 1.73 m(-2) , albuminuria or both. The proportions of patients achieving nationally defined glycaemic and systolic blood pressure targets were determined. The cohort comprised 1,423,669 patients, of whom 868,616 (61%) met inclusion criteria. Of the patients analysed, 92.2% had Type 2 diabetes. A higher proportion of people with Type 2 diabetes (42.3%) had renal dysfunction compared with those with Type 1 diabetes (32.4%). Achievement of systolic blood pressure and HbA1c targets was poor. Among people with Type 1 diabetes, 67.8% failed to achieve an HbA1c < 58 mmol/mol (7.5%). Of all people with diabetes, 37.8% failed to achieve a systolic blood pressure < 140 mmHg. Blood pressure control was poor in advanced chronic kidney disease. For example, mean (standard deviation) systolic blood pressure rose from 128.6 (15.4) mmHg among people with Type 1 diabetes and normal renal function to 141.0 (23.6) mmHg in those with chronic kidney disease stage 5 and macroalbuminuria. The high prevalence of chronic kidney disease and poor attainment of treatment targets highlights a large subset of the diabetes population at increased risk of cardiovascular mortality or progressive kidney disease. © 2013 The Authors. Diabetic Medicine © 2013 Diabetes UK.
Blood flow structure in patients with coronary heart disease
NASA Astrophysics Data System (ADS)
Malinova, Lidia I.; Simonenko, Georgy V.; Denisova, Tatyana P.; Tuchin, Valery V.
2007-05-01
Blood flow structure was studied by PC integrated video camera with following slide by slide analysis. Volumetric blood flow velocity was supporting on constant level (1 ml/h). Silicone tube of diameter comparable with coronary arteries diameter was used as vessel model. Cell-cell interactions were studied under glucose and anticoagulants influence. Increased adhesiveness of blood cells to tube walls was revealed in patient with coronary heart disease (CHD) compare to practically healthy persons (PHP). In patients with stable angina pectoris of high functional class and patients with AMI shear stress resistant erythrocyte aggregates were predominating in blood flow structure up to microclots formation. Clotting and erythrocytes aggregation increase as response to glucose solution injection, sharply defined in patients with CHD. Heparin injection (10 000 ED) increased linear blood flow velocity both in patients with CHD and PHP. After compare our results with other author's data we can consider that method used in our study is sensible enough to investigate blood flow structure violations in patients with CHD and PHP. Several differences of cell-cell interaction in flow under glucose and anticoagulant influence were found out in patients with CHD and PHP.
NASA Astrophysics Data System (ADS)
Fedosov, Dmitry
2011-03-01
Computational biophysics is a large and rapidly growing area of computational physics. In this talk, we will focus on a number of biophysical problems related to blood cells and blood flow in health and disease. Blood flow plays a fundamental role in a wide range of physiological processes and pathologies in the organism. To understand and, if necessary, manipulate the course of these processes it is essential to investigate blood flow under realistic conditions including deformability of blood cells, their interactions, and behavior in the complex microvascular network. Using a multiscale cell model we are able to accurately capture red blood cell mechanics, rheology, and dynamics in agreement with a number of single cell experiments. Further, this validated model yields accurate predictions of the blood rheological properties, cell migration, cell-free layer, and hemodynamic resistance in microvessels. In addition, we investigate blood related changes in malaria, which include a considerable stiffening of red blood cells and their cytoadherence to endothelium. For these biophysical problems computational modeling is able to provide new physical insights and capabilities for quantitative predictions of blood flow in health and disease.
Cueno, Marni E; Seki, Keisuke; Ochiai, Kuniyasu; Imai, Kenichi
2017-03-01
Periodontal diseases are partly attributable to periodontopathic bacteria found in the host, whereas, butyric acid (BA) is a common secondary metabolite produced by periodontopathic bacterial pathogens. BA has been linked to oxidative stress induction while oxidative stress has long been associated with the ageing process. However, the possible link between BA-induced oxidative stress and the ageing process has never been elucidated. Here, we attempted to show the possible role of periodontal diseaselevel-BA (PDL-BA) in influencing the rat blood ageing process. We injected PDL-BA into the young rat gingiva and, after 24h, heart blood extraction was performed. Blood obtained from PDL-BA-treated young rats was compared to untreated young and middle-aged rats. We found that cytosolic, but not mitochondrial, heme was affected 24h post-injection. In addition, we observed that PDL-BA treatment altered blood NOX activation, NADPH-related oxidative stress components (H 2 O 2 and GR), calcium homeostasis, cell death signals (CASP3 and CASP1), and age-related markers (SIRT1 and mTOR) in young rats, with some components more closely mimicking levels found in middle-aged rats. In this regard, we propose that PDL-BA may play a role in contributing to the rat blood ageing process. Copyright © 2017 Elsevier B.V. All rights reserved.
Patient safety with blood products administration using wireless and bar-code technology.
Porcella, Aleta; Walker, Kristy
2005-01-01
Supported by a grant from the Agency for Healthcare Research and Quality, a University of Iowa Hospitals and Clinics interdisciplinary research team created an online data-capture-response tool utilizing wireless mobile devices and bar code technology to track and improve blood products administration process. The tool captures 1) sample collection, 2) sample arrival in the blood bank, 3) blood product dispense from blood bank, and 4) administration. At each step, the scanned patient wristband ID bar code is automatically compared to scanned identification barcode on requisition, sample, and/or product, and the system presents either a confirmation or an error message to the user. Following an eight-month, 5 unit, staged pilot, a 'big bang,' hospital-wide implementation occurred on February 7, 2005. Preliminary results from pilot data indicate that the new barcode process captures errors 3 to 10 times better than the old manual process.
[A specific questionnaire to evaluate therapeutic inertia in hypertensive patients: a pilot study].
Pretorean, T; Claisse, G; Delsart, P; Caudrelier, T; Devos, P; Mounier-Vehier, C
2014-02-01
Therapeutic inertia (TI) is a recent concept still unknown by many physicians. In chronic diseases such as hypertension, it is defined as the tendency of physicians not to increase or change antihypertensive medications when the target blood pressure is not reached. Acting on TI could improve blood pressure control in France. This was a single-center prospective pilot study conducted by hypertension specialist physicians at the University Cardio-Vascular Center in Lille (France). It was conducted between March and June 2011. Data was collected from 161 hypertensive patients (mean age: 61.64±11.18 years; 98 (60.9%) male; 75 secondary prevention patients). Each physician completed a questionnaire on therapeutic inertia. TI was defined as a consultation in which treatment change was indicated (systolic blood pressure [BP]≥140 and/or diastolic BP≥90mmHg in all patients), but did not occur, with absence of an adapted justification of this choice. We considered as an adapted justification: a white coat effect demonstrated by ambulatory blood pressure monitoring (ABPM) or home blood pressure monitoring; scheduled reassessment of the BP by ABPM; recent change in antihypertensive treatment (less than 4 weeks); hospitalization needed for complete evaluation of secondary causes of hypertension and a more detailed assessment of potential target organ damage in patients with grade 1 or 2 hypertension. Our study aimed to evaluate rates of TI, to identify factors associated with TI, and to test the TI questionnaire. Therapeutic inertia as defined in this study occurred in 11 consultations (8.3%) of the 133 hypertensive patients having uncontrolled BP above or equal to 140 and/or 90mmHg. Significant factors associated with TI were older age (Z=2.35, P<0.05) and sleep apnea syndrome (χ(2)=8.33, P<0.05). The absence of ambulatory blood pressure monitoring before the consultation (χ(2)=4.28, 0.1>P>0.05) and the number of consultations (Z=1.92, 0.1>P>0.05) exhibited a significant trend to be associated with TI. Although the rate of TI was low in our study conducted in a specialized center, a well-accepted definition of therapeutic inertia would be useful for further study. The feasibility of using the questionnaire tested with this study shows that this measurement tool could help physicians become more aware of TI, both in the hospital and primary care setting. Further multicenter studies are needed for validation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Optimization of camera exposure durations for multi-exposure speckle imaging of the microcirculation
Kazmi, S. M. Shams; Balial, Satyajit; Dunn, Andrew K.
2014-01-01
Improved Laser Speckle Contrast Imaging (LSCI) blood flow analyses that incorporate inverse models of the underlying laser-tissue interaction have been used to develop more quantitative implementations of speckle flowmetry such as Multi-Exposure Speckle Imaging (MESI). In this paper, we determine the optimal camera exposure durations required for obtaining flow information with comparable accuracy with the prevailing MESI implementation utilized in recent in vivo rodent studies. A looping leave-one-out (LOO) algorithm was used to identify exposure subsets which were analyzed for accuracy against flows obtained from analysis with the original full exposure set over 9 animals comprising n = 314 regional flow measurements. From the 15 original exposures, 6 exposures were found using the LOO process to provide comparable accuracy, defined as being no more than 10% deviant, with the original flow measurements. The optimal subset of exposures provides a basis set of camera durations for speckle flowmetry studies of the microcirculation and confers a two-fold faster acquisition rate and a 28% reduction in processing time without sacrificing accuracy. Additionally, the optimization process can be used to identify further reductions in the exposure subsets for tailoring imaging over less expansive flow distributions to enable even faster imaging. PMID:25071956
Bukara, Katarina; Drvenica, Ivana; Ilić, Vesna; Stančić, Ana; Mišić, Danijela; Vasić, Borislav; Gajić, Radoš; Vučetić, Dušan; Kiekens, Filip; Bugarski, Branko
2016-12-20
The objective of our study was to develop controlled drug delivery system based on erythrocyte ghosts for amphiphilic compound sodium diclofenac considering the differences between erythrocytes derived from two readily available materials - porcine slaughterhouse and outdated transfusion human blood. Starting erythrocytes, empty erythrocyte ghosts and diclofenac loaded ghosts were compared in terms of the encapsulation efficiency, drug releasing profiles, size distribution, surface charge, conductivity, surface roughness and morphology. The encapsulation of sodium diclofenac was performed by an osmosis based process - gradual hemolysis. During this process sodium diclofenac exerted mild and delayed antihemolytic effect and increased potassium efflux in porcine but not in outdated human erythrocytes. FTIR spectra revealed lack of any membrane lipid disorder and chemical reaction with sodium diclofenac in encapsulated ghosts. Outdated human erythrocyte ghosts with detected nanoscale damages and reduced ability to shrink had encapsulation efficiency of only 8%. On the other hand, porcine erythrocyte ghosts had encapsulation efficiency of 37% and relatively slow drug release rate. More preserved structure and functional properties of porcine erythrocytes related to their superior encapsulation and release performances, define them as more appropriate for the usage in sodium diclofenac encapsulation process. Copyright © 2016 Elsevier B.V. All rights reserved.
Quality control in the development of coagulation factor concentrates.
Snape, T J
1987-01-01
Limitation of process change is a major factor contributing to assurance of quality in pharmaceutical manufacturing. This is particularly true in the manufacture of coagulation factor concentrates, for which presumptive testing for poorly defined product characteristics is an integral feature of finished product quality control. The development of new or modified preparations requires that this comfortable position be abandoned, and that the effect on finished product characteristics of changes to individual process steps (and components) be assessed. The degree of confidence in the safety and efficacy of the new product will be determined by, amongst other things, the complexity of the process alteration and the extent to which the results of finished product tests can be considered predictive. The introduction of a heat-treatment step for inactivation of potential viral contaminants in coagulation factor concentrates presents a significant challenge in both respects, quite independent of any consideration of assessment of the effectiveness of the viral inactivation step. These interactions are illustrated by some of the problems encountered with terminal dry heat-treatment (72 h. at 80 degrees C) of factor VIII and prothrombin complex concentrates manufactured by the Blood Products Laboratory.
The genetics of myelodysplastic syndrome: from clonal haematopoiesis to secondary leukaemia.
Sperling, Adam S; Gibson, Christopher J; Ebert, Benjamin L
2017-01-01
Myelodysplastic syndrome (MDS) is a clonal disease that arises from the expansion of mutated haematopoietic stem cells. In a spectrum of myeloid disorders ranging from clonal haematopoiesis of indeterminate potential (CHIP) to secondary acute myeloid leukaemia (sAML), MDS is distinguished by the presence of peripheral blood cytopenias, dysplastic haematopoietic differentiation and the absence of features that define acute leukaemia. More than 50 recurrently mutated genes are involved in the pathogenesis of MDS, including genes that encode proteins involved in pre-mRNA splicing, epigenetic regulation and transcription. In this Review we discuss the molecular processes that lead to CHIP and further clonal evolution to MDS and sAML. We also highlight the ways in which these insights are shaping the clinical management of MDS, including classification schemata, prognostic scoring systems and therapeutic approaches.