Francisco, Ana Lucia Noronha; Correr, Wagner Rafael; Azevedo, Luciane Hiramatsu; Kern, Vivian Galletta; Pinto, Clóvis Antônio Lopes; Kowalski, Luiz Paulo; Kurachi, Cristina
2014-06-01
Oral cancer is a public health problem with relevant incidence in the world population. The affected patient usually presents advanced stage disease and the consequence of this delay is a reduction in survival rates. Given this, it is essential to detect oral cancer at early stages. Fluorescence spectroscopy is a non-invasive diagnostic tool that can improve cancer detection in real time. It is a fast and accurate technique, relatively simple, which evaluates the biochemical composition and structure using the tissue fluorescence spectrum as interrogation data. Several studies have positive data regarding the tools for differentiating between normal mucosa and cancer, but the difference between cancer and potentially malignant disorders is not clear. The aim of this study was to evaluate the efficacy of fluorescence spectroscopy in the discrimination of normal oral mucosa, oral cancer, and potentially malignant disorders. The fluorescence spectroscopy was evaluated in 115 individuals, of whom 55 patients presented oral squamous cell carcinoma, 30 volunteers showing normal oral mucosa, and 30 patients having potentially malignant disorders. The spectra were classified and compared to histopathology to evaluate the efficiency in diagnostic discrimination employing fluorescence. In order to classify the spectra, a decision tree algorithm (C4.5) was applied. Despite of the high variance observed in spectral data, the specificity and sensitivity obtained were 93.8% and 88.5%, respectively at 406 nm excitation. These results point to the potential use of fluorescence spectroscopy as an important tool for oral cancer diagnosis and potentially malignant disorders. Copyright © 2014 Elsevier B.V. All rights reserved.
Sy, Jolene R.; Vollmer, Timothy R.
2012-01-01
We evaluated the discrimination acquisition of individuals with developmental disabilities under immediate and delayed reinforcement. In Experiment 1, discrimination between two alternatives was examined when reinforcement was immediate or delayed by 20 s, 30 s, or 40 s. In Experiment 2, discrimination between 2 alternatives was compared across an immediate reinforcement condition and a delayed reinforcement condition in which subjects could respond during the delay. In Experiment 3, discrimination among 4 alternatives was compared across immediate and delayed reinforcement. In Experiment 4, discrimination between 2 alternatives was examined when reinforcement was immediate and 0-s or 30-s intertrial intervals (ITI) were programmed. For most subjects, discrimination acquisition occurred under immediate reinforcement. However, for some subjects, introducing delays slowed or prevented discrimination acquisition under some conditions. Results from Experiment 4 suggest that longer ITIs cannot account for the lack of discrimination under delayed reinforcement. PMID:23322925
[Discrimination of Red Tide algae by fluorescence spectra and principle component analysis].
Su, Rong-guo; Hu, Xu-peng; Zhang, Chuan-song; Wang, Xiu-lin
2007-07-01
Fluorescence discrimination technology for 11 species of the Red Tide algae at genus level was constructed by principle component analysis and non-negative least squares. Rayleigh and Raman scattering peaks of 3D fluorescence spectra were eliminated by Delaunay triangulation method. According to the results of Fisher linear discrimination, the first principle component score and the second component score of 3D fluorescence spectra were chosen as discriminant feature and the feature base was established. The 11 algae species were tested, and more than 85% samples were accurately determinated, especially for Prorocentrum donghaiense, Skeletonema costatum, Gymnodinium sp., which have frequently brought Red tide in the East China Sea. More than 95% samples were right discriminated. The results showed that the genus discriminant feature of 3D fluorescence spectra of Red Tide algae given by principle component analysis could work well.
ERIC Educational Resources Information Center
Sy, Jolene R.; Vollmer, Timothy R.
2012-01-01
We evaluated the discrimination acquisition of individuals with developmental disabilities under immediate and delayed reinforcement. In Experiment 1, discrimination between two alternatives was examined when reinforcement was immediate or delayed by 20 s, 30 s, or 40 s. In Experiment 2, discrimination between 2 alternatives was compared across an…
Panneton, Bernard; Guillaume, Serge; Roger, Jean-Michel; Samson, Guy
2010-01-01
Precision weeding by spot spraying in real time requires sensors to discriminate between weeds and crop without contact. Among the optical based solutions, the ultraviolet (UV) induced fluorescence of the plants appears as a promising alternative. In a first paper, the feasibility of discriminating between corn hybrids, monocotyledonous, and dicotyledonous weeds was demonstrated on the basis of the complete spectra. Some considerations about the different sources of fluorescence oriented the focus to the blue-green fluorescence (BGF) part, ignoring the chlorophyll fluorescence that is inherently more variable in time. This paper investigates the potential of performing weed/crop discrimination on the basis of several large spectral bands in the BGF area. A partial least squares discriminant analysis (PLS-DA) was performed on a set of 1908 spectra of corn and weed plants over 3 years and various growing conditions. The discrimination between monocotyledonous and dicotyledonous plants based on the blue-green fluorescence yielded robust models (classification error between 1.3 and 4.6% for between-year validation). On the basis of the analysis of the PLS-DA model, two large bands were chosen in the blue-green fluorescence zone (400-425 nm and 425-490 nm). A linear discriminant analysis based on the signal from these two bands also provided very robust inter-year results (classification error from 1.5% to 5.2%). The same selection process was applied to discriminate between monocotyledonous weeds and maize but yielded no robust models (up to 50% inter-year error). Further work will be required to solve this problem and provide a complete UV fluorescence based sensor for weed-maize discrimination.
Jaffee, Kim D; Shires, Deirdre A; Stroumsa, Daphna
2016-11-01
The transgender community experiences health care discrimination and approximately 1 in 4 transgender people were denied equal treatment in health care settings. Discrimination is one of the many factors significantly associated with health care utilization and delayed care. We assessed factors associated with delayed medical care due to discrimination among transgender patients, and evaluated the relationship between perceived provider knowledge and delayed care using Anderson's behavioral model of health services utilization. Multivariable logistic regression analysis was used to test whether predisposing, enabling, and health system factors were associated with delaying needed care for transgender women and transgender men. A sample of 3486 transgender participants who took part in the National Transgender Discrimination Survey in 2008 and 2009. Predisposing, enabling, and health system environment factors, and delayed needed health care. Overall, 30.8% of transgender participants delayed or did not seek needed health care due to discrimination. Respondents who had to teach health care providers about transgender people were 4 times more likely to delay needed health care due to discrimination. Transgender patients who need to teach their providers about transgender people are significantly more likely to postpone or not seek needed care. Systemic changes in provider education and training, along with health care system adaptations to ensure appropriate, safe, and respectful care, are necessary to close the knowledge and treatment gaps and prevent delayed care with its ensuing long-term health implications.
USDA-ARS?s Scientific Manuscript database
In this study, we developed a nondestructive method for discriminating viable cucumber (Cucumis sativus) seeds based on hyperspectral fluorescence imaging. The fluorescence spectra of cucumber seeds in the 420–700 nm range were extracted from hyperspectral fluorescence images obtained using 365 nm u...
Imamura, Ryota; Murata, Naoki; Shimanouchi, Toshinori; Yamashita, Kaoru; Fukuzawa, Masayuki; Noda, Minoru
2017-01-01
A new fluorescent arrayed biosensor has been developed to discriminate species and concentrations of target proteins by using plural different phospholipid liposome species encapsulating fluorescent molecules, utilizing differences in permeation of the fluorescent molecules through the membrane to modulate liposome-target protein interactions. This approach proposes a basically new label-free fluorescent sensor, compared with the common technique of developed fluorescent array sensors with labeling. We have confirmed a high output intensity of fluorescence emission related to characteristics of the fluorescent molecules dependent on their concentrations when they leak from inside the liposomes through the perturbed lipid membrane. After taking an array image of the fluorescence emission from the sensor using a CMOS imager, the output intensities of the fluorescence were analyzed by a principal component analysis (PCA) statistical method. It is found from PCA plots that different protein species with several concentrations were successfully discriminated by using the different lipid membranes with high cumulative contribution ratio. We also confirmed that the accuracy of the discrimination by the array sensor with a single shot is higher than that of a single sensor with multiple shots. PMID:28714873
Imamura, Ryota; Murata, Naoki; Shimanouchi, Toshinori; Yamashita, Kaoru; Fukuzawa, Masayuki; Noda, Minoru
2017-07-15
A new fluorescent arrayed biosensor has been developed to discriminate species and concentrations of target proteins by using plural different phospholipid liposome species encapsulating fluorescent molecules, utilizing differences in permeation of the fluorescent molecules through the membrane to modulate liposome-target protein interactions. This approach proposes a basically new label-free fluorescent sensor, compared with the common technique of developed fluorescent array sensors with labeling. We have confirmed a high output intensity of fluorescence emission related to characteristics of the fluorescent molecules dependent on their concentrations when they leak from inside the liposomes through the perturbed lipid membrane. After taking an array image of the fluorescence emission from the sensor using a CMOS imager, the output intensities of the fluorescence were analyzed by a principal component analysis (PCA) statistical method. It is found from PCA plots that different protein species with several concentrations were successfully discriminated by using the different lipid membranes with high cumulative contribution ratio. We also confirmed that the accuracy of the discrimination by the array sensor with a single shot is higher than that of a single sensor with multiple shots.
Harms, Floor A; de Boon, Wadim M I; Balestra, Gianmarco M; Bodmer, Sander I A; Johannes, Tanja; Stolker, Robert J; Mik, Egbert G
2011-10-01
Mitochondrial oxygen tension can be measured in vivo by means of oxygen-dependent quenching of delayed fluorescence of protoporphyrin IX (PpIX). Here we demonstrate that delayed fluorescence is readily observed from skin in rat and man after topical application of the PpIX precursor 5-aminolevulinic acid (ALA). Delayed fluorescence lifetimes respond to changes in inspired oxygen fraction and blood supply. The signals contain lifetime distributions and the fitting of rectangular distributions to the data appears more adequate than mono-exponential fitting. The use of topically applied ALA for delayed fluorescence lifetime measurements might pave the way for clinical use of this technique. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Discrimination of corn from monocotyledonous weeds with ultraviolet (UV) induced fluorescence.
Panneton, Bernard; Guillaume, Serge; Samson, Guy; Roger, Jean-Michel
2011-01-01
In production agriculture, savings in herbicides can be achieved if weeds can be discriminated from crop, allowing the targeting of weed control to weed-infested areas only. Previous studies demonstrated the potential of ultraviolet (UV) induced fluorescence to discriminate corn from weeds and recently, robust models have been obtained for the discrimination between monocots (including corn) and dicots. Here, we developed a new approach to achieve robust discrimination of monocot weeds from corn. To this end, four corn hybrids (Elite 60T05, Monsanto DKC 26-78, Pioneer 39Y85 (RR), and Syngenta N2555 (Bt, LL)) and four monocot weeds (Digitaria ischaemum (Schreb.) I, Echinochloa crus-galli (L.) Beauv., Panicum capillare (L.), and Setaria glauca (L.) Beauv.) were grown either in a greenhouse or in a growth cabinet and UV (327 nm) induced fluorescence spectra (400 to 755 nm) were measured under controlled or uncontrolled ambient light intensity and temperature. This resulted in three contrasting data sets suitable for testing the robustness of discrimination models. In the blue-green region (400 to 550 nm), the shape of the spectra did not contain any useful information for discrimination. Therefore, the integral of the blue-green region (415 to 455 nm) was used as a normalizing factor for the red fluorescence intensity (670 to 755 nm). The shape of the normalized red fluorescence spectra did not contribute to the discrimination and in the end, only the integral of the normalized red fluorescence intensity was left as a single discriminant variable. Applying a threshold on this variable minimizing the classification error resulted in calibration errors ranging from 14.2% to 15.8%, but this threshold varied largely between data sets. Therefore, to achieve robustness, a model calibration scheme was developed based on the collection of a calibration data set from 75 corn plants. From this set, a new threshold can be estimated as the 85% quantile on the cumulative frequency curve of the integral of the normalized red fluorescence. With this approach the classification error was nearly constant (16.0% to 18.5%), thereby indicating the potential of UV-induced fluorescence to reliably discriminate corn from monocot weeds.
Discrimination of petroleum fluorescence spectra.
Stelmaszewski, Adam
2007-01-01
This paper presents studies of the total spectra (fluorescence-excitation matrix) of petroleum with regard to the utilization of fluorescence for determining petroleum pollutants. Thorough testing of one group, comprising almost forty lubricating oils in the form of their hexane solutions, points out their discrimination.
Long-lived efficient delayed fluorescence organic light-emitting diodes using n-type hosts.
Cui, Lin-Song; Ruan, Shi-Bin; Bencheikh, Fatima; Nagata, Ryo; Zhang, Lei; Inada, Ko; Nakanotani, Hajime; Liao, Liang-Sheng; Adachi, Chihaya
2017-12-21
Organic light-emitting diodes have become a mainstream display technology because of their desirable features. Third-generation electroluminescent devices that emit light through a mechanism called thermally activated delayed fluorescence are currently garnering much attention. However, unsatisfactory device stability is still an unresolved issue in this field. Here we demonstrate that electron-transporting n-type hosts, which typically include an acceptor moiety in their chemical structure, have the intrinsic ability to balance the charge fluxes and broaden the recombination zone in delayed fluorescence organic electroluminescent devices, while at the same time preventing the formation of high-energy excitons. The n-type hosts lengthen the lifetimes of green and blue delayed fluorescence devices by > 30 and 1000 times, respectively. Our results indicate that n-type hosts are suitable to realize stable delayed fluorescence organic electroluminescent devices.
Perceived Discrimination and Reported Delay of Pharmacy Prescriptions and Medical Tests
Van Houtven, Courtney Harold; Voils, Corrine I; Oddone, Eugene Z; Weinfurt, Kevin P; Friedman, Joëlle Y; Schulman, Kevin A; Bosworth, Hayden B
2005-01-01
BACKGROUND Access to health care varies according to a person's race and ethnicity. Delaying treatment is one measure of access with important health consequences. OBJECTIVE Determine whether perceptions of unfair treatment because of race or ethnicity are associated with reported treatment delays, controlling for economic constraints, self-reported health, depression, and demographics. DESIGN Cross-sectional, observational study. PARTICIPANTS A randomly selected community sample of 181 blacks, 148 Latinos, and 193 whites in Durham County, NC. MEASUREMENTS A phone survey conducted in 2002 to assess discrimination, trust in medical care, quality of care, and access to care. Treatment delays were measured by whether or not a person reported delaying or forgoing filling a prescription and delaying or forgoing having a medical test/treatment in the past 12 months. Perceived discrimination was measured as unfair treatment in health care and as racism in local health care institutions. RESULTS The odds of delaying filling prescriptions were significantly higher (odds ratio (OR)=2.02) for persons who perceived unfair treatment, whereas the odds of delaying tests or treatments were significantly higher (OR=2.42) for persons who thought racism was a problem in health care locally. People with self-reported depression and people who reported not working had greater odds of delaying both types of care. CONCLUSIONS A prospective cohort study with both personal and macro measures of discrimination, as well as more refined measures of treatment delays, would help us better understand the relationship between perceived discrimination and treatment delays. PMID:16050850
NASA Astrophysics Data System (ADS)
Francisco, A. L. N.; Correr, W. R.; Azevedo, L. H.; Galletta, V. K.; Pinto, C. A. L.; Kowalski, L. P.; Kurachi, C.
2014-01-01
Oral cancer is a major health problem worldwide and although early diagnosis of potentially malignant and malignant diseases is associated with better treatment results, a large number of cancers are initially misdiagnosed, with unfortunate consequences for long-term survival. Fluorescence spectroscopy is a noninvasive modality of diagnostic approach using induced fluorescence emission in tumors that can improve diagnostic accuracy. The objective of this study was to determine the ability to discriminate between normal oral mucosa and potentially malignant disorders by fluorescence spectroscopy. Fluorescence investigation under 408 and 532 nm excitation wavelengths was performed on 60 subjects, 30 with potentially malignant disorders and 30 volunteers with normal mucosa. Data was analyzed to correlate fluorescence patterns with clinical and histopathological diagnostics. Fluorescence spectroscopy used as a point measurement technique resulted in a great variety of spectral information. In a qualitative analysis of the fluorescence spectral characteristics of each type of injury evaluated, it was possible to discriminate between normal and abnormal oral mucosa. The results show the potential use of fluorescence spectroscopy for an improved discrimination of oral disorders.
Kwon, Hyukin; Jiang, Wei
2015-01-01
Many existing irrigation, industrial and chemical storage sites are currently introducing hazardous anions into groundwater, making the monitoring of such sites a high priority. Detecting and quantifying anions in water samples typically requires complex instrumentation, adding cost and delaying analysis. Here we address these challenges by development of an optical molecular method to detect and discriminate a broad range of anionic contaminants with DNA-based fluorescent sensors. A library of 1296 tetrameric-length oligodeoxyfluorosides (ODFs) composed of metal ligand and fluorescence modulating monomers was constructed with a DNA synthesizer on PEG-polystyrene microbeads. These oligomers on beads were incubated with YIII or ZnII ions to provide affinity and responsiveness to anions. Seventeen anions were screened with the library under an epifluorescence microscope, ultimately yielding eight chemosensors that could discriminate 250 μM solutions of all 17 anions in buffered water using their patterns of response. This sensor set was able to identify two unknown anion samples from ten closely-responding anions and could also function quantitatively, determining unknown concentrations of anions such as cyanide (as low as 1 mM) and selenate (as low as 50 μM). Further studies with calibration curves established detection limits of selected anions including thiocyanate (detection limit ∼300 μM) and arsenate (∼800 μM). The results demonstrate DNA-like fluorescent chemosensors as versatile tools for optically analyzing environmentally hazardous anions in aqueous environments. PMID:26146537
Individual bioaerosol particle discrimination by multi-photon excited fluorescence.
Kiselev, Denis; Bonacina, Luigi; Wolf, Jean-Pierre
2011-11-21
Femtosecond laser induced multi-photon excited fluorescence (MPEF) from individual airborne particles is tested for the first time for discriminating bioaerosols. The fluorescence spectra, analysed in 32 channels, exhibit a composite character originating from simultaneous two-photon and three-photon excitation at 790 nm. Simulants of bacteria aggregates (clusters of dyed polystyrene microspheres) and different pollen particles (Ragweed, Pecan, Mulberry) are clearly discriminated by their MPEF spectra. This demonstration experiment opens the way to more sophisticated spectroscopic schemes like pump-probe and coherent control. © 2011 Optical Society of America
NASA Astrophysics Data System (ADS)
Kozankiewicz, B.; Prochorow, J.
1989-08-01
Fluorescence, phosphorescence and delayed fluorescence emission characteristics of tetracyanobenzene-hexamethylbenzene (TCNB-HMB) charge-transfer crystal have been studied in the 1.7-340 K temperature range. Delayed fluorescence, originating from heterogeneous triplet-triplet annihilation indicates the presence of mobile charge-transfer triplet excitons at a temperature as low as 1.7 K. However, the behaviour of triplet excitons in TCNB-HMB crystal is strongly controlled by a very efficient trapping process in the whole temperature range investigated. It was found that thermally activated delayed fluorescence, which is a dominating emission of the crystal at elevated temperatures (>60 K), has a different origin (a different initial state) at different temperatures. These observations were analysed and interpreted in terms of a photokinetic model, which is considered to be typical for charge-transfer crystals with high charge-transfer character of triplet excitons.
Hagihara, Kenta; Tsukagoshi, Kazuhiko; Nakajima, Chinami; Esaki, Shinsuke; Hashimoto, Masahiko
2016-01-01
We previously developed a separation-free ligase detection reaction assay based on fluorescence resonance energy transfer from a donor quantum dot to an acceptor fluorescent dye. This assay could successfully detect one cancer mutation among 10 wild-type templates. In the current study, the mutation-discrimination threshold was improved by one order of magnitude by replacing the original acceptor dye (Alexa Fluor 647) with another fluorescent dye (Cyanine 5) that was spectrally similar but more fluorescent.
Seelman, Kristie L.; Colón-Diaz, Matthew J.P.; LeCroix, Rebecca H.; Xavier-Brier, Marik; Kattari, Leonardo
2017-01-01
Abstract Purpose: There are many barriers to reliable healthcare for transgender people that often contribute to delaying or avoiding needed medical care. Yet, few studies have examined whether noninclusive healthcare and delaying needed medical care because of fear of discrimination are associated with poorer health among transgender adults. This study aims to address these gaps in the knowledge base. Methods: This study analyzed secondary data from a statewide survey of 417 transgender adults in the Rocky Mountain region of the United States. Independent variables included noninclusive healthcare from a primary care provider (PCP) and delay of needed medical care because of fear of discrimination. Dependent variables assessed general health and mental health. Results: Transgender individuals who delayed healthcare because of fear of discrimination had worse general health in the past month than those who did not delay or delayed care for other reasons (B=−0.26, p<0.05); they also had 3.08 greater odds of having current depression, 3.81 greater odds of a past year suicide attempt, and 2.93 greater odds of past year suicidal ideation (p<0.001). After controlling for delayed care because of fear of discrimination, having a noninclusive PCP was not significantly associated with either general health or mental health. Conclusion: This study suggests a significant association between delaying healthcare because of fear of discrimination and worse general and mental health among transgender adults. These relationships remain significant even when controlling for provider noninclusivity, suggesting that fear of discrimination and consequent delay of care are at the forefront of health challenges for transgender adults. The lack of statistical significance for noninclusive healthcare may be related to the measurement approach used; future research is needed to develop an improved tool for measuring transgender noninclusive healthcare. PMID:28861545
ERIC Educational Resources Information Center
Kral, Paul A.; And Others
Investigates the effect of delay of reinforcement upon human discrimination learning with particular emphasis on the form of the gradient within the first few seconds of delay. In previous studies subjects are usually required to make an instrumental response to a stimulus, this is followed by the delay interval, and finally, the reinforcement…
Gan, Shifeng; Hu, Shimin; Li, Xiang-Long; Zeng, Jiajie; Zhang, Dongdong; Huang, Tianyu; Luo, Wenwen; Zhao, Zujin; Duan, Lian; Su, Shi-Jian; Tang, Ben Zhong
2018-05-23
Raising triplet exciton utilization of pure organic luminescent materials is of significant importance for efficiency advancement of organic light-emitting diodes (OLEDs). Herein, by introducing bromine atom(s) onto a typical molecule (bis(carbazol-9-yl)-4,5-dicyanobenzene) with thermally activated delayed fluorescence, we demonstrate that the heavy atom effect of bromine can increase spin-orbit coupling and promote the reverse intersystem crossing, which endow the molecules with more distinct delayed fluorescence. In consequence, the triplet exciton utilization is improved greatly with the increase of bromine atoms, affording apparently advanced external quantum efficiencies of OLEDs. Utilizing the enhancement effect of bromine atoms on delayed fluorescence should be a simple and promising design concept for efficient organic luminogens with high exciton utilization.
Spectral line discriminator for passive detection of fluorescence
NASA Technical Reports Server (NTRS)
Kebabian, Paul L. (Inventor)
1996-01-01
A method and apparatus for detecting fluorescence from sunlit plants is based on spectral line discrimination using the A-band and B-band absorption of atmospheric oxygen. Light from a plant including scattered sunlight and the fluorescence from chlorophyll is passed through a chopper into a cell containing low-pressure, high-purity oxygen. A-band or B-band wavelengths present in the light are absorbed by the oxygen in the cell. When the chopper is closed, the absorbed light is remitted as fluorescence into a detector. The intensity of the fluorescence from the oxygen is proportional to the intensity of fluorescence from the plant.
Apparatus for eliminating background interference in fluorescence measurements
Martin, J.C.; Jett, J.H.
1984-01-06
The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser which excites a different stained component of the same biological particle.
Apparatus for eliminating background interference in fluorescence measurements
Martin, John C.; Jett, James H.
1986-01-01
The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser, which excites a different stained component of the same biological particle.
Apparatus for eliminating background interference in fluorescence measurements
Martin, J.C.; Jett, J.H.
1986-03-04
The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser, which excites a different stained component of the same biological particle. 8 figs.
Snapshot imaging Fraunhofer line discriminator for detection of plant fluorescence
NASA Astrophysics Data System (ADS)
Gupta Roy, S.; Kudenov, M. W.
2015-05-01
Non-invasive quantification of plant health is traditionally accomplished using reflectance based metrics, such as the normalized difference vegetative index (NDVI). However, measuring plant fluorescence (both active and passive) to determine photochemistry of plants has gained importance. Due to better cost efficiency, lower power requirements, and simpler scanning synchronization, detecting passive fluorescence is preferred over active fluorescence. In this paper, we propose a high speed imaging approach for measuring passive plant fluorescence, within the hydrogen alpha Fraunhofer line at ~656 nm, using a Snapshot Imaging Fraunhofer Line Discriminator (SIFOLD). For the first time, the advantage of snapshot imaging for high throughput Fraunhofer Line Discrimination (FLD) is cultivated by our system, which is based on a multiple-image Fourier transform spectrometer and a spatial heterodyne interferometer (SHI). The SHI is a Sagnac interferometer, which is dispersion compensated using blazed diffraction gratings. We present data and techniques for calibrating the SIFOLD to any particular wavelength. This technique can be applied to quantify plant fluorescence at low cost and reduced complexity of data collection.
Intrinsic fluorescence based in-vivo detection of cervical precancer with hand held prototype device
NASA Astrophysics Data System (ADS)
Meena, Bharat Lal; Raikwar, Akanksha; Pandey, Kiran; Agarwal, Asha; Pantola, Chayanika; Pradhan, Asima
2018-02-01
A prototype device (hand held probe) designed and fabricated in the lab has been tested for cervical precancer detection using intrinsic fluorescence. The intrinsic fluorescence gets strongly modulated by the interplay of scattering and absorption. This masks valuable biochemical information which is present in the intrinsic fluorescence. These distortion effects can be minimized by normalizing the polarized fluorescence spectra by the polarized elastic scattering spectra. The measurements have been made with a in-house fabricated device using a 405 nm diode laser and white light source respectively. 166 sites of different grades of cervical pre-cancer biopsy samples (CIN I and CIN II) (CIN: cervical intraepithelial neoplastic) have been discriminated from 29 sites of normal biopsy samples using principal component analysis (PCA) based linear discriminant analysis (LDA). The sensitivity and specificity for discrimination of normal samples from CIN I are found to be 99% and 96% respectively. Further the normal samples can be discriminated from CIN II samples with 96% sensitivity and 96% specificity. Based on these promising ex-vivo results an in-vivo study on patients has been initiated in the hospital. The hand held device built in-house shows promise as a useful tool for in vivo cervical precancer detection by polarized fluorescence. Preliminary in-vivo results on 10 patients indicate the efficacy of the hand held device for screening cervical precancers using intrinsic fluorescence.
NASA Astrophysics Data System (ADS)
Wang, Xue F.; Periasamy, Ammasi; Wodnicki, Pawel; Siadat-Pajouh, M.; Herman, Brian
1995-04-01
We have been interested in the role of Human Papillomavirus (HPV) in cervical cancer and its diagnosis; to that end we have been developing microscopic imaging and fluorescent in situ hybridization (FISH) techniques to genotype and quantitate the amount of HPV present at a single cell level in cervical PAP smears. However, we have found that low levels of HPV DNA are difficult to detect accurately because theoretically obtainable sensitivity is never achieved due to nonspecific autofluorescence, fixative induced fluorescence of cells and tissues, and autofluorescence of the optical components in the microscopic system. In addition, the absorption stains used for PAP smears are intensely autofluorescent. Autofluorescence is a rapidly decaying process with lifetimes in the range of 1-100 nsec, whereas phosphorescence and delayed fluorescence have lifetimes in the range of 1 microsecond(s) ec-10 msec. The ability to discriminate between specific fluorescence and autofluorescence in the time-domain has improved the sensitivity of diagnostic test such that they perform comparably to, or even more sensitive than radioisotopic assays. We have developed a novel time-resolved fluorescence microscope to improve the sensitivity of detection of specific molecules of interest in slide based specimens. This time-resolved fluorescence microscope is based on our recently developed fluorescence lifetime imaging microscopy (FILM) in conjunction with the use of long lifetime fluorescent labels. By using fluorescence in situ hybridization and the long lifetime probe (europium), we have demonstrated the utility of this technique for detection of HPV DNA in cervicovaginal cells. Our results indicate that the use of time-resolved fluorescence microscopy and long lifetime probes increases the sensitivity of detection by removing autofluorescence and will thus lead to improved early diagnosis of cervical cancer. Since the highly sensitive detection of DNA in clinical samples using fluorescence in situ hybridization image is useful for the diagnosis of many other type of diseases, the system we have developed should find numerous applications for the diagnosis of disease states.
A Diagnostic Marker to Discriminate Childhood Apraxia of Speech from Speech Delay: Introduction
ERIC Educational Resources Information Center
Shriberg, Lawrence D.; Strand, Edythe A.; Fourakis, Marios; Jakielski, Kathy J.; Hall, Sheryl D.; Karlsson, Heather B.; Mabie, Heather L.; McSweeny, Jane L.; Tilkens, Christie M.; Wilson, David L.
2017-01-01
Purpose: The goal of this article is to introduce the pause marker (PM), a single-sign diagnostic marker proposed to discriminate early or persistent childhood apraxia of speech (CAS) from speech delay.
Delayed temporal discrimination in pigeons: A comparison of two procedures
Chatlosh, Diane L.; Wasserman, Edward A.
1987-01-01
A within-subjects comparison was made of pigeons' performance on two temporal discrimination procedures that were signaled by differently colored keylight samples. During stimulus trials, a peck on the key displaying a slanted line was reinforced following short keylight samples, and a peck on the key displaying a horizontal line was reinforced following long keylight samples, regardless of the location of the stimuli on those two choice keys. During position trials, a peck on the left key was reinforced following short keylight samples and a peck on the right key was reinforced following long keylight samples, regardless of which line stimulus appeared on the correct key. Thus, on stimulus trials, the correct choice key could not be discriminated prior to the presentation of the test stimuli, whereas on position trials, the correct choice key could be discriminated during the presentation of the sample stimulus. During Phase 1, with a 0-s delay between sample and choice stimuli, discrimination learning was faster on position trials than on stimulus trials for all 4 birds. During Phase 2, 0-, 0.5-, and 1.0-s delays produced differential loss of stimulus control under the two tasks for 2 birds. Response patterns during the delay intervals provided some evidence for differential mediation of the two delayed discriminations. These between-task differences suggest that the same processes may not mediate performance in each. PMID:16812483
Pigeons' Discrimination of Michotte's Launching Effect
Young, Michael E; Beckmann, Joshua S; Wasserman, Edward A
2006-01-01
We trained four pigeons to discriminate a Michotte launching animation from three other animations using a go/no-go task. The pigeons received food for pecking at one of the animations, but not for pecking at the others. The four animations featured two types of interactions among objects: causal (direct launching) and noncausal (delayed, distal, and distal & delayed). Two pigeons were reinforced for pecking at the causal interaction, but not at the noncausal interactions; two other pigeons were reinforced for pecking at the distal & delayed interaction, but not at the other interactions. Both discriminations proved difficult for the pigeons to master; later tests suggested that the pigeons often learned the discriminations by attending to subtle stimulus properties other than the intended ones. PMID:17002229
Optical Spectroscopic Analysis for the Discrimination of Extra-Virgin Olive Oil.
McReynolds, Naomi; Auñón Garcia, Juan M; Guengerich, Zoe; Smith, Terry K; Dholakia, Kishan
2016-11-01
We demonstrate the ability to discriminate between five brands of commercially available extra-virgin olive oil (EVOO) using Raman spectroscopy or fluorescence spectroscopy. Data was taken on both a 'bulk optics' free space system and on a compact handheld device, each capable of taking both Raman and fluorescence data. With the compact Raman device we achieved an average sensitivity and specificity of 98.4% and 99.6% for discrimination, respectively. Our approach illustrates that both Raman and fluorescence spectroscopy can be used for portable discrimination of EVOOs. This technique may enable detection of EVOO that has undergone counterfeiting or adulteration. The main challenge with this technique is that oxidation of EVOO causes a shift in the Raman signal over time. It would therefore be necessary to retrain the database regularly. We demonstrate preliminary data to address this issue, which may enable successful discrimination over time. We show that by discarding the first principal component, which contains information on the variations due to oxidation, we can improve discrimination efficiency. © The Author(s) 2016.
Shang, Jianyuan; Geva, Eitan
2007-04-26
The quenching rate of a fluorophore attached to a macromolecule can be rather sensitive to its conformational state. The decay of the corresponding fluorescence lifetime autocorrelation function can therefore provide unique information on the time scales of conformational dynamics. The conventional way of measuring the fluorescence lifetime autocorrelation function involves evaluating it from the distribution of delay times between photoexcitation and photon emission. However, the time resolution of this procedure is limited by the time window required for collecting enough photons in order to establish this distribution with sufficient signal-to-noise ratio. Yang and Xie have recently proposed an approach for improving the time resolution, which is based on the argument that the autocorrelation function of the delay time between photoexcitation and photon emission is proportional to the autocorrelation function of the square of the fluorescence lifetime [Yang, H.; Xie, X. S. J. Chem. Phys. 2002, 117, 10965]. In this paper, we show that the delay-time autocorrelation function is equal to the autocorrelation function of the square of the fluorescence lifetime divided by the autocorrelation function of the fluorescence lifetime. We examine the conditions under which the delay-time autocorrelation function is approximately proportional to the autocorrelation function of the square of the fluorescence lifetime. We also investigate the correlation between the decay of the delay-time autocorrelation function and the time scales of conformational dynamics. The results are demonstrated via applications to a two-state model and an off-lattice model of a polypeptide.
Fluorescent polymer sensor array for detection and discrimination of explosives in water.
Woodka, Marc D; Schnee, Vincent P; Polcha, Michael P
2010-12-01
A fluorescent polymer sensor array (FPSA) was made from commercially available fluorescent polymers coated onto glass beads and was tested to assess the ability of the array to discriminate between different analytes in aqueous solution. The array was challenged with exposures to 17 different analytes, including the explosives trinitrotoluene (TNT), tetryl, and RDX, various explosive-related compounds (ERCs), and nonexplosive electron-withdrawing compounds (EWCs). The array exhibited a natural selectivity toward EWCs, while the non-electron-withdrawing explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) produced no response. Response signatures were visualized by principal component analysis (PCA), and classified by linear discriminant analysis (LDA). RDX produced the same response signature as the sampled blanks and was classified accordingly. The array exhibited excellent discrimination toward all other compounds, with the exception of the isomers of nitrotoluene and aminodinitrotoluene. Of particular note was the ability of the array to discriminate between the three isomers of dinitrobenzene. The natural selectivity of the FPSA toward EWCs, plus the ability of the FPSA to discriminate between different EWCs, could be used to design a sensor with a low false alarm rate and an excellent ability to discriminate between explosives and explosive-related compounds.
NASA Astrophysics Data System (ADS)
Raimondi, Valentina; Palombi, Lorenzo; Lognoli, David; Masini, Andrea; Simeone, Emilio
2017-09-01
This paper presents experimental tests and radiometric calculations for the feasibility of an ultra-compact fluorescence LIDAR from an Unmanned Air Vehicle (UAV) for the characterisation of oil spills in natural waters. The first step of this study was to define the experimental conditions for a LIDAR and its budget constraints on the basis of the specifications of small UAVs already available on the market. The second step consisted of a set of fluorescence LIDAR measurements on oil spills in the laboratory in order to propose a simplified discrimination method and to calculate the oil fluorescence conversion efficiency. Lastly, the main technical specifications of the payload were defined and radiometric calculations carried out to evaluate the performances of both the payload and the proposed discrimination method.
NASA Astrophysics Data System (ADS)
Meena, Bharat Lal; Singh, Pankaj; Sah, Amar Nath; Pandey, Kiran; Agarwal, Asha; Pantola, Chayanika; Pradhan, Asima
2018-01-01
An in-house fabricated portable device has been tested to detect cervical precancer through the intrinsic fluorescence from human cervix of the whole uterus in a clinical setting. A previously validated technique based on simultaneously acquired polarized fluorescence and polarized elastic scattering spectra from a turbid medium is used to extract the intrinsic fluorescence. Using a diode laser at 405 nm, intrinsic fluorescence of flavin adenine dinucleotide, which is the dominant fluorophore and other contributing fluorophores in the epithelium of cervical tissue, has been extracted. Different grades of cervical precancer (cervical intraepithelial neoplasia; CIN) have been discriminated using principal component analysis-based Mahalanobis distance and linear discriminant analysis. Normal, CIN I and CIN II samples have been discriminated from one another with high sensitivity and specificity at 95% confidence level. This ex vivo study with cervix of whole uterus samples immediately after hysterectomy in a clinical environment indicates that the in-house fabricated portable device has the potential to be used as a screening tool for in vivo precancer detection using intrinsic fluorescence.
Mani, Tomoyasu; Vinogradov, Sergei A
2013-08-06
Photon upconversion based on sensitized triplet-triplet annihilation (TTA) presents interest for such areas as photovoltaics and imaging. Usually energy upconversion is observed as p -type delayed fluorescence from molecules whose triplet states are populated via energy transfer from a suitable triplet donor, followed by TTA. Magnetic field effects (MFE) on delayed fluorescence in molecular crystals are well known; however, there exist only a few examples of MFE on TTA in solutions, and all of them are limited to UV-emitting materials. Here we present MFE on TTA-mediated visible and near infrared (NIR) emission, sensitized by far-red absorbing metalloporphyrins in solutions at room temperature. In addition to visible delayed fluorescence from annihilator, we also observed NIR emission from the sensitizer, occurring as a result of triplet-triplet energy transfer back from annihilator, termed "delayed phosphorescence". This emission also exhibits MFE, but opposite in sign to the annihilator fluorescence.
Fluorescence spectroscopy applied to orange trees
NASA Astrophysics Data System (ADS)
Marcassa, L. G.; Gasparoto, M. C. G.; Belasque, J., Jr.; Lins, E. C.; Dias Nunes, F.; Bagnato, V. S.
2006-05-01
In this work, we have applied laser-induced fluorescence spectroscopy to investigate biological processes in orange trees (Citrus aurantium L.). We have chosen to investigate water stress and Citrus Canker, which is a disease caused by the Xanthomonas axonopodis pv. citri bacteria. The fluorescence spectroscopy was investigated by using as an excitation source a 442-nm 15-mW HeCd gas multimode discharge laser and a 532-nm 10-mW Nd3+:YAG laser. The stress manifestation was detected by the variation of fluorescence ratios of the leaves at different wavelengths. The fluorescence ratios present a significant variation, showing the possibility to observe water stress by fluorescence spectrum. The Citrus Canker’s contaminated leaves were discriminated from the healthy leaves using a more complex analysis of the fluorescence spectra. However, we were unable to discriminate it from another disease, and new fluorescence experiments are planned for the future.
Noise interference with echo delay discrimination in bat biosonar.
Simmons, J A
2017-11-01
Echolocating big brown bats (Eptesicus fuscus) were trained in a two-choice task to discriminate differences in the delay of electronic echoes at 1.7 ms delay (30 cm simulated range). Difference thresholds (∼45 μs) were comparable to previously published results. At selected above-threshold differences (116 and 232 μs delay), performance was measured in the presence of wideband random noise at increasing amplitudes in 10-dB steps to determine the noise level that prevented discrimination. Performance eventually failed, but the bats increased the amplitude and duration of their broadcasts to compensate for increasing noise, which allowed performance to persist at noise levels about 25 dB higher than without compensation. In the 232-μs delay discrimination condition, echo signal-to-noise ratio (2E/N 0 ) was 8-10 dB at the noise level that depressed performance to chance. Predicted echo-delay accuracy using big brown bat signals follows the Cramér-Rao bound for signal-to-noise ratios above 15 dB, but worsens below 15 dB due to side-peak ambiguity. At 2E/N 0 = 7-10 dB, predicted Cramér-Rao delay accuracy would be about 1 μs; considering side-peak ambiguity it would be about 200-300 μs. The bats' 232 μs performance reflects the intrusion of side-peak ambiguity into delay accuracy at low signal-to-noise ratios.
NASA Astrophysics Data System (ADS)
Quiers, M.; Perrette, Y.; Jacq, K.; Pousset, E.; Plassart, G.
2017-12-01
OM fluorescence is today a well-developed tool used to characterize and quantify organic matter (OM), but also to evaluate and discriminate OM fate and changes related to climate and environmental modifications. While fluorescence measurements on water and soils extracts provide information about organic fluxes today, solid phase fluorescence using natural archives allows to obtain high resolution records of OM evolution during time. These evolutions can be discussed in regards of climate and environmental perturbations detected in archives using different proxies, and thus provide keys for understanding factors driving carbon fluxes mechanisms. Among fluorescent organic species, Polycyclic Aromatic Hydrocarbons (PAH) have been used as probe molecules for organic contamination tracking. Moreover, monitoring studies have shown that PAH could also be used as markers to discriminates atmospheric and erosion factors leading to PAH and organic matter fluxes to the aquifer. PAH records in soils and natural archives appear as a promising proxy to follow both past atmospheric contamination and soil erosion. But, PAH fluorescence is difficult to discriminate from bulk OM fluorescence using steady-state fluorescence (SSF) technics as their fluorescence domains recover. Time resolved emission spectroscopy (TRES) increases the information provided by SSF technic, adding a time dimension to measurements and allowing to discriminate PAH fluorescence. We report here a first application of this technic on natural archives. The challenge is to obtain TRES signature along the sample, including for low PAH concentrations. This study aims to evaluate the reliability of high resolution TRES measurement as PAH carbon fluxes sources. Method is based on LIF instrument for solid phase fluorescence measurement. An instrument coupling an excitation system constituting by 2 pulsed lasers (266 and 355 nm) and a detection system was developed. This measurement provides high resolution record of PAH fluorescence. Preliminary results on stalagmite samples, lake sediments and soils will be reported. PAH content variations along the sample were compared with PAH concentration and with bulk OM content deduced from SSF records. The accuracy of the PAH fluorescence as source marker of fluxes will be discussed for each type of sample.
Tomato seeds maturity detection system based on chlorophyll fluorescence
NASA Astrophysics Data System (ADS)
Li, Cuiling; Wang, Xiu; Meng, Zhijun
2016-10-01
Chlorophyll fluorescence intensity can be used as seed maturity and quality evaluation indicator. Chlorophyll fluorescence intensity of seed coats is tested to judge the level of chlorophyll content in seeds, and further to judge the maturity and quality of seeds. This research developed a detection system of tomato seeds maturity based on chlorophyll fluorescence spectrum technology, the system included an excitation light source unit, a fluorescent signal acquisition unit and a data processing unit. The excitation light source unit consisted of two high power LEDs, two radiators and two constant current power supplies, and it was designed to excite chlorophyll fluorescence of tomato seeds. The fluorescent signal acquisition unit was made up of a fluorescence spectrometer, an optical fiber, an optical fiber scaffolds and a narrowband filter. The data processing unit mainly included a computer. Tomato fruits of green ripe stage, discoloration stage, firm ripe stage and full ripe stage were harvested, and their seeds were collected directly. In this research, the developed tomato seeds maturity testing system was used to collect fluorescence spectrums of tomato seeds of different maturities. Principal component analysis (PCA) method was utilized to reduce the dimension of spectral data and extract principal components, and PCA was combined with linear discriminant analysis (LDA) to establish discriminant model of tomato seeds maturity, the discriminant accuracy was greater than 90%. Research results show that using chlorophyll fluorescence spectrum technology is feasible for seeds maturity detection, and the developed tomato seeds maturity testing system has high detection accuracy.
Huang, Yuanyuan; Zhou, Jin; Feng, Hui; Zheng, Jieyu; Ma, Hui-Min; Liu, Weidong; Tang, Cong; Ao, Hang; Zhao, Meizhi; Qian, Zhaosheng
2016-12-15
A convenient, fluorescent dual-channel chemosensor on the basis of bis(3-pyridylmethyl)amine-functionalized carbon quantum dots (BPMA-CQDs) nanoprobe was constructed, and it can discriminatively detect glutathione from its analogues cysteine and homocysteine based on two distinctive strategies. Two distinct fluorescence responses of BPMA-CQDs probe to Cu(II) and Ag(I) were identified and further employed to achieve selective detection of Cu(II) and Ag(I) respectively. Based on the BPMA-CQDs/Cu(II) conjugate, discriminative detection of GSH was achieved in terms of correlation between the amounts of GSH and fluorescence recovery. The addition of GSH into BPMA-CQDs/Cu(II) system induces the reduction of Cu(II) to Cu(I), which could efficiently block PET process resulting in the following fluorescence recovery. Based on the BPMA-CQDs/Ag(I) conjugate, GSH assay could also be established on the basis of fluorescence response to GSH. The introduction of GSH into the preceding system triggers the competitive coordination to Ag(I) between BPMA and GSH, and silver ions are finally taken away by GSH from the probe, where the fluorescence is restored to its original weak state. Both of the detection strategies can achieve discriminative detection of GSH from Cys and Hcy. The assays showed good stability and repeatability, and covered a broad linear range of up to 13.3μM with a lowest detection limit of 42.0nM. Moreover, both of them were utilized to monitor GSH level in live cells. Copyright © 2016 Elsevier B.V. All rights reserved.
Discriminative stimuli that follow a delay have added value for pigeons.
DiGian, Kelly A; Friedrich, Andrea M; Zentall, Thomas R
2004-10-01
Clement, Feltus, Kaiser, and Zentall (2000) reported that pigeons prefer discriminative stimuli that require greater effort (more pecks) to obtain over those that require less effort. In the present experiment, we examined two variables associated with this phenomenon. First, we asked whether delay of reinforcement, presumably a relatively aversive event similar to effort, would produce similar effects. Second, we asked whether the stimulus preference produced by a prior relatively aversive event depends on its anticipation. Anticipation of delay was accomplished by signaling its occurrence. Results indicated that delays can produce preferences similar to those produced by increased effort, but only if the delays are signaled.
USDA-ARS?s Scientific Manuscript database
A multi-spectral fluorescence imaging technique was used to detect defect cherry tomatoes. The fluorescence excitation and emission matrix was used to measure for defects, sound surface, and stem areas to determine the optimal fluorescence excitation and emission wavelengths for discrimination. Two-...
Santolaria, Pilar; Pauciullo, Alfredo; Silvestre, Miguel A; Vicente-Fiel, Sandra; Villanova, Leyre; Pinton, Alain; Viruel, Juan; Sales, Ester; Yániz, Jesús L
2016-01-01
This study was designed to determine the ability of computer-assisted sperm morphometry analysis (CASA-Morph) with fluorescence to discriminate between spermatozoa carrying different sex chromosomes from the nuclear morphometrics generated and different statistical procedures in the bovine species. The study was divided into two experiments. The first was to study the morphometric differences between X- and Y-chromosome-bearing spermatozoa (SX and SY, respectively). Spermatozoa from eight bulls were processed to assess simultaneously the sex chromosome by FISH and sperm morphometry by fluorescence-based CASA-Morph. SX cells were larger than SY cells on average (P < 0.001) although with important differences between bulls. A simultaneous evaluation of all the measured features by discriminant analysis revealed that nuclear area and average fluorescence intensity were the variables selected by stepwise discriminant function analysis as the best discriminators between SX and SY. In the second experiment, the sperm nuclear morphometric results from CASA-Morph in nonsexed (mixed SX and SY) and sexed (SX) semen samples from four bulls were compared. FISH allowed a successful classification of spermatozoa according to their sex chromosome content. X-sexed spermatozoa displayed a larger size and fluorescence intensity than nonsexed spermatozoa (P < 0.05). We conclude that the CASA-Morph fluorescence-based method has the potential to find differences between X- and Y-chromosome-bearing spermatozoa in bovine species although more studies are needed to increase the precision of sex determination by this technique.
Plant stress detection by remote measurement of fluorescence
McFarlane, J. C.; Watson, Robert D.; Theisen, Arnold F.; Jackson, R. D.; Ehrler, W. L.; Pinter, P. J.; Idso, S. B.; Reginato, R. J.
1980-01-01
Chlorophyll fluorescence of mature lemon trees was measured with a Fraunhofer line discriminator (FLD). An increase in fluorescence was correlated with plant water stress as measured by stomatal resistance and twig water potential.
Signal-Detection Analyses of Conditional Discrimination and Delayed Matching-to-Sample Performance
ERIC Educational Resources Information Center
Alsop, Brent
2004-01-01
Quantitative analyses of stimulus control and reinforcer control in conditional discriminations and delayed matching-to-sample procedures often encounter a problem; it is not clear how to analyze data when subjects have not made errors. The present article examines two common methods for overcoming this problem. Monte Carlo simulations of…
Hondrogiannis, Ellen; Rotta, Kathryn; Zapf, Charles M
2013-03-01
Sixteen elements found in 37 vanilla samples from Madagascar, Uganda, India, Indonesia (all Vanilla planifolia species), and Papa New Guinea (Vanilla tahitensis species) were measured by wavelength dispersive X-ray fluorescence (WDXRF) spectroscopy for the purpose of determining the elemental concentrations to discriminate among the origins. Pellets were prepared of the samples and elemental concentrations were calculated based on calibration curves created using 4 Natl. Inst. of Standards and Technology (NIST) standards. Discriminant analysis was used to successfully classify the vanilla samples by their species and their geographical region. Our method allows for higher throughput in the rapid screening of vanilla samples in less time than analytical methods currently available. Wavelength dispersive X-ray fluorescence spectroscopy and discriminant function analysis were used to classify vanilla from different origins resulting in a model that could potentially serve to rapidly validate these samples before purchasing from a producer. © 2013 Institute of Food Technologists®
Neural correlates of target selection for reaching movements in superior colliculus
McPeek, Robert M.
2014-01-01
We recently demonstrated that inactivation of the primate superior colliculus (SC) causes a deficit in target selection for arm-reaching movements when the reach target is located in the inactivated field (Song JH, Rafal RD, McPeek RM. Proc Natl Acad Sci USA 108: E1433–E1440, 2011). This is consistent with the notion that the SC is part of a general-purpose target selection network beyond eye movements. To understand better the role of SC activity in reach target selection, we examined how individual SC neurons in the intermediate layers discriminate a reach target from distractors. Monkeys reached to touch a color oddball target among distractors while maintaining fixation. We found that many SC neurons robustly discriminate the goal of the reaching movement before the onset of the reach even though no saccade is made. To identify these cells in the context of conventional SC cell classification schemes, we also recorded visual, delay-period, and saccade-related responses in a delayed saccade task. On average, SC cells that discriminated the reach target from distractors showed significantly higher visual and delay-period activity than nondiscriminating cells, but there was no significant difference in saccade-related activity. Whereas a majority of SC neurons that discriminated the reach target showed significant delay-period activity, all nondiscriminating cells lacked such activity. We also found that some cells without delay-period activity did discriminate the reach target from distractors. We conclude that the majority of intermediate-layer SC cells discriminate a reach target from distractors, consistent with the idea that the SC contains a priority map used for effector-independent target selection. PMID:25505107
Fluorescent discrimination between traces of chemical warfare agents and their mimics.
Díaz de Greñu, Borja; Moreno, Daniel; Torroba, Tomás; Berg, Alexander; Gunnars, Johan; Nilsson, Tobias; Nyman, Rasmus; Persson, Milton; Pettersson, Johannes; Eklind, Ida; Wästerby, Pär
2014-03-19
An array of fluorogenic probes is able to discriminate between nerve agents, sarin, soman, tabun, VX and their mimics, in water or organic solvent, by qualitative fluorescence patterns and quantitative multivariate analysis, thus making the system suitable for the in-the-field detection of traces of chemical warfare agents as well as to differentiate between the real nerve agents and other related compounds.
NASA Astrophysics Data System (ADS)
Park, Young-Seo; Kim, Kwon-Hyeon; Kim, Jang-Joo
2013-04-01
Efficient triplet harvesting from exciplexes by reverse intersystem crossing (RISC) is reported using a fluorescent molecular system composed of the 4,4',4″-tris(N-carbazolyl)-triphenylamine and bis-4,6-(3,5-di-3-pyridylphenyl)-2-methylpyrimidine. The exciplex forming material system shows the efficient delayed fluorescence emission. As a result, almost 100% PL efficiency at 35 K and 10% external quantum efficiency at 195 K are achieved from the exciplex. The delayed fluorescence of the exciplex clearly demonstrates that a significant proportion of the triplet exciplexes is harvested through the RISC.
NASA Astrophysics Data System (ADS)
Kang, Yongxiang; Zhao, Liyun; Leng, Jiancai
2018-04-01
Design of red organic emitting molecules with characteristic of thermally activated delayed fluorescence (TADF) remains a great challenge. Here, electronic and optical properties of a series of multi-branched TADF molecules have been investigated based on the newly-proposed optimal Hartree-Fock percentage method. Results show that, though enlarging the delocalization of HOMO and LUMO, the emission wavelength is redshift. The designed red TADF molecule possesses smaller reorganization energy than these for reported molecules. This indicates the non-radiative energy consumption of excited state is small and effective luminescence can be expected. Thus, a promising red thermally activated delayed fluorescence molecule is proposed.
NASA Astrophysics Data System (ADS)
Rekha, Pachaiappan; Aruna, Prakasa Rao; Ganesan, Singaravelu
2016-03-01
Many research works based on fluorescence spectroscopy have proven its potential in the diagnosis of various diseases using the spectral signatures of the native key fluorophores such as tryptophan, tyrosine, collagen, NADH, FAD and porphyrin. These fluorophores distribution, concentration and their conformation may be changed depending upon the pathological and metabolic conditions of cells and tissues. In this study, we have made an attempt to characterize the blood plasma of normal subject and oral cancer patients by native fluorescence spectroscopy at 280 nm excitation. Further, the fluorescence data were analyzed by employing the multivariate statistical method - linear discriminant analyses (LDA) using leaves one out cross validation method. The results illustrate the potential of fluorescence spectroscopy technique in the diagnosis of oral cancer using blood plasma.
Glick, Jennifer L; Theall, Katherine P; Andrinopoulos, Katherine M; Kendall, Carl
2018-04-01
This study examines the associations between discrimination experiences (types and locations) and care postponement among trans-feminine individuals in the United States. This secondary, cross-sectional study utilized a subset of the data from the National Transgender Discrimination Survey (n = 2248), specifically for trans-feminine individuals. In this analysis, we examined the relationship between discrimination and primary care postponement. Twenty-six percent (26.25%) of the study sample reported delaying preventive care due to fear of discrimination; 23.98%-46.66% of respondents reported past experiences of discrimination (setting dependent). Discrimination in health and non-health settings and different types of discrimination-being denied services, verbally harassed, or physically assaulted-were all significantly associated with delaying care; respondents reporting discrimination were up to 20 times more likely to postpone care. While discrimination at a health location had the strongest association with care postponement (adjusted odds ratio = 9.65, confidence interval = 7.60-12.24), discrimination in all non-health-related locations was also important. Individuals reporting discrimination in greater numbers of locations and multiple types of discrimination were more likely to postpone care. To promote preventive care-seeking, these results affirm the importance of interventions that promote discrimination-free environments for gender minorities.
Time-resolved delayed luminescence image microscopy using an europium ion chelate complex.
Marriott, G.; Heidecker, M.; Diamandis, E. P.; Yan-Marriott, Y.
1994-01-01
Improvements and extended applications of time-resolved delayed luminescence imaging microscopy (TR-DLIM) in cell biology are described. The emission properties of europium ion complexed to a fluorescent chelating group capable of labeling proteins are exploited to provide high contrast images of biotin labeled ligands through detection of the delayed emission. The streptavidin-based macromolecular complex (SBMC) employs streptavidin cross-linked to thyroglobulin multiply labeled with the europium-fluorescent chelate. The fluorescent chelate is efficiently excited with 340-nm light, after which it sensitizes europium ion emission at 612 nm hundreds of microseconds later. The SBMC complex has a high quantum yield orders of magnitude higher than that of eosin, a commonly used delayed luminescent probe, and can be readily seen by the naked eye, even in specimens double-labeled with prompt fluorescent probes. Unlike triplet-state phosphorescent probes, sensitized europium ion emission is insensitive to photobleaching and quenching by molecular oxygen; these properties have been exploited to obtain delayed luminescence images of living cells in aerated medium thus complementing imaging studies using prompt fluorescent probes. Since TR-DLIM has the unique property of rejecting enormous signals that originate from scattered light, autofluorescence, and prompt fluorescence it has been possible to resolve double emission images of living amoeba cells containing an intensely stained lucifer yellow in pinocytosed vesicles and membrane surface-bound SBMC-labeled biotinylated concanavalin A. Images of fixed cells represented in terms of the time decay of the sensitized emission show the lifetime of the europium ion emission is sensitive to the environment in which it is found. Through the coupling of SBMC to streptavidin,a plethora of biotin-based tracer molecules are available for immunocytochemical studies. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 PMID:7811952
He, Longwei; Yang, Xueling; Xu, Kaixin; Kong, Xiuqi
2017-01-01
Biothiols, which have a close network of generation and metabolic pathways among them, are essential reactive sulfur species (RSS) in the cells and play vital roles in human physiology. However, biothiols possess highly similar chemical structures and properties, resulting in it being an enormous challenge to simultaneously discriminate them from each other. Herein, we develop a unique fluorescent probe (HMN) for not only simultaneously distinguishing Cys/Hcy, GSH, and H2S from each other, but also sequentially sensing Cys/Hcy/GSH and H2S using a multi-channel fluorescence mode for the first time. When responding to the respective biothiols, the robust probe exhibits multiple sets of fluorescence signals at three distinct emission bands (blue-green-red). The new probe can also sense H2S at different concentration levels with changes of fluorescence at the blue and red emission bands. In addition, the novel probe HMN is able to discriminate and sequentially sense biothiols in biological environments via three-color fluorescence imaging. We expect that the development of the robust probe HMN will provide a powerful strategy to design fluorescent probes for the discrimination and sequential detection of biothiols, and offer a promising tool for exploring the interrelated roles of biothiols in various physiological and pathological conditions. PMID:28989659
Analysis of surgical margins in oral cancer using in situ fluorescence spectroscopy.
Francisco, Ana Lucia Noronha; Correr, Wagner Rafael; Pinto, Clóvis Antônio Lopes; Gonçalves Filho, João; Chulam, Thiago Celestino; Kurachi, Cristina; Kowalski, Luiz Paulo
2014-06-01
Oral cancer is a public health problem with high prevalence in the population. Local tumor control is best achieved by complete surgical resection with adequate margins. A disease-free surgical margin correlates with a lower rate of local recurrence and a higher rate of disease-free survival. Fluorescence spectroscopy is a noninvasive diagnostic tool that can aid in real-time cancer detection. The technique, which evaluates the biochemical composition and structure of tissue fluorescence, is relatively simple, fast and, accurate. This study aimed to compare oral squamous cell carcinoma lesions to surgical margins and the mucosa of healthy volunteers by fluorescence spectroscopy. The sample consisted of 56 individuals, 28 with oral squamous cell carcinoma and 28 healthy volunteers with normal oral mucosa. Thirty six cases (64.3%) were male and the mean age was 60.9 years old. The spectra were classified and compared to histopathology to determine fluorescence efficiency for diagnostic discrimination of tumors. In the analysis of the other cases we observed discrimination between normal mucosa, injury and margins. At two-year follow up, three individuals had local recurrence, and in two cases investigation fluorescence in the corresponding area showed qualitative differences in spectra between the recurrence area and the area without recurrence at the same anatomical site in the same patient. In situ analysis of oral mucosa showed the potential of fluorescence spectroscopy as a diagnostic tool that can aid in discrimination of altered mucosa and normal mucosa. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Enderlein, Joerg; Ruhlandt, Daja; Chithik, Anna; Ebrecht, René; Wouters, Fred S.; Gregor, Ingo
2016-02-01
Fluorescence lifetime microscopy has become an important method of bioimaging, allowing not only to record intensity and spectral, but also lifetime information across an image. One of the most widely used methods of FLIM is based on Time-Correlated Single Photon Counting (TCSPC). In TCSPC, one determines this curve by exciting molecules with a periodic train of short laser pulses, and then measuring the time delay between the first recorded fluorescence photon after each exciting laser pulse. An important technical detail of TCSPC measurements is the fact that the delay times between excitation laser pulses and resulting fluorescence photons are always measured between a laser pulse and the first fluorescence photon which is detected after that pulse. At high count rates, this leads to so-called pile-up: ``early'' photons eclipse long-delay photons, resulting in heavily skewed TCSPC histograms. To avoid pile-up, a rule of thumb is to perform TCSPC measurements at photon count rates which are at least hundred times smaller than the laser-pulse excitation rate. The downside of this approach is that the fluorescence-photon count-rate is restricted to a value below one hundredth of the laser-pulse excitation-rate, reducing the overall speed with which a fluorescence signal can be measured. We present a new data evaluation method which provides pile-up corrected fluorescence decay estimates from TCSPC measurements at high count rates, and we demonstrate our method on FLIM of fluorescently labeled cells.
ERIC Educational Resources Information Center
Shriberg, Lawrence D.; Strand, Edythe A.; Fourakis, Marios; Jakielski, Kathy J.; Hall, Sheryl D.; Karlsson, Heather B.; Mabie, Heather L.; McSweeny, Jane L.; Tilkens, Christie M.; Wilson, David L.
2017-01-01
Purpose: The goal of this article (PM I) is to describe the rationale for and development of the Pause Marker (PM), a single-sign diagnostic marker proposed to discriminate early or persistent childhood apraxia of speech from speech delay. Method: The authors describe and prioritize 7 criteria with which to evaluate the research and clinical…
NASA Astrophysics Data System (ADS)
Yamanoi, Kohei; Hori, Tatsuhiro; Minami, Yuki; Empizo, Melvin John F.; Luong, Mui Viet; Shiro, Atsushi; Watanabe, Jun; Iwano, Keisuke; Iwasa, Yuki; Cadatal-Raduban, Marilou; Gabayno, Jacque Lynn; Shimizu, Toshihiko; Sarukura, Nobuhiko; Norimatsu, Takayoshi
2018-01-01
We report the fluorescence spectra of ZrO2 and trivalent Ho-doped ZrO2 ceramics under ultraviolet (UV) excitation at 213, 266, and 355 nm wavelengths. The Ho3+-doped ZrO2 ceramics exhibited varying fluorescence color tones depending on the excitation wavelength used. The different color tones match the fluorescence spectrum characteristics at each excitation wavelength. Our results demonstrate that Ho3+-doped ZrO2 ceramics can discriminate between UV light, specifically the third, fourth, and fifth harmonics of a Nd:YAG laser. It can potentially be used for developing UV laser beam viewers to aid laser alignment.
NASA Astrophysics Data System (ADS)
McReynolds, Naomi; Auñón Garcia, Juan M.; Guengerich, Zoe; Smith, Terry K.; Dholakia, Kishan
2017-02-01
We present an optical spectroscopic technique, making use of both Raman signals and fluorescence spectroscopy, for the identification of five brands of commercially available extra-virgin olive-oil (EVOO). We demonstrate our technique on both a `bulk-optics' free-space system and a compact device. Using the compact device, which is capable of recording both Raman and fluorescence signals, we achieved an average sensitivity and specificity of 98.4% and 99.6% for discrimination, respectively. Our approach demonstrates that both Raman and fluorescence spectroscopy can be used for portable discrimination of EVOOs which obviates the need to use centralised laboratories and opens up the prospect of in-field testing. This technique may enable detection of EVOO that has undergone counterfeiting or adulteration. One of the main challenges facing Raman spectroscopy for use in quality control of EVOOs is that the oxidation of EVOO, which naturally occurs due to aging, causes shifts in Raman spectra with time, which implies regular retraining would be necessary. We present a potential method of analysis to minimize the effect that aging has on discrimination efficiency; we show that by discarding the first principal component, which contains information on the variations due to oxidation, we can improve discrimination efficiency thus improving the robustness of our technique.
Thermally activated delayed fluorescence of a Zr-based metal–organic framework
Mieno, H.; Kabe, R.; Allendorf, M. D.; ...
2017-12-22
Here, the first metal–organic framework exhibiting thermally activated delayed fluorescence (TADF) was developed. The zirconium-based framework (UiO-68-dpa) uses a newly designed linker composed of a terphenyl backbone, an electron-accepting carboxyl group, and an electron-donating diphenylamine and exhibits green TADF emission with a photoluminescence quantum yield of 30% and high thermal stability.
Mayr, Susanne; Köpper, Maja; Buchner, Axel
2013-01-01
Legislation in many countries has banned inefficient household lighting. Consequently, classic incandescent lamps have to be replaced by more efficient alternatives such as halogen and compact fluorescent lamps (CFL). Alternatives differ in their spectral power distributions, implying colour-rendering differences. Participants performed a colour discrimination task - the Farnsworth-Munsell 100 Hue Test--and a proofreading task under CFL or halogen lighting of comparable correlated colour temperatures at low (70 lx) or high (800 lx) illuminance. Illuminance positively affected colour discrimination and proofreading performance, whereas the light source was only relevant for colour discrimination. Discrimination was impaired with CFL lighting. There were no differences between light sources in terms of self-reported physical discomfort and mood state, but the majority of the participants correctly judged halogen lighting to be more appropriate for discriminating colours. The findings hint at the colour-rendering deficiencies associated with energy-efficient CFLs. In order to compare performance under energy-efficient alternatives of classic incandescent lighting, colour discrimination and proofreading performance was compared under CFL and halogen lighting. Colour discrimination was impaired under CFLs, which hints at the practical drawbacks associated with the reduced colour-rendering properties of energy-efficient CFLs.
Widefield fluorescence sectioning with HiLo microscopy.
Mertz, Jerome; Lim, Daryl; Chu, Kengyeh K; Bozinovic, Nenad; Ford, Timothy
2009-01-01
HiLo microscopy is a widefield fluorescence imaging technique that provides depth discrimination by combining two images, one with non-uniform illumination and one with uniform illumination. We discuss the theory of this technique and a variety of practical implementations in brain-tissue imaging and fluorescence endomicroscopy.
NASA Astrophysics Data System (ADS)
Connally, Russell; Veal, Duncan; Piper, James A.
2003-07-01
The abundance of naturally fluorescing components (autofluorophors) encountered in environmentally sourced samples can greatly hinder the detection and identification of fluorescently labeled target using fluorescence microscopy. Time-resolved fluorescence microscopy (TRFM) is a technique that reduces the effects of autofluorescence through precisely controlled time delays. Lanthanide chelates have fluorescence lifetimes many orders of magnitude greater than typical autofluorophors, and persist in their luminescence long after autofluorescence has ceased. An intense short pulse of (UV) light is used to excite fluorescence in the sample and after a short delay period the longer persisting fluorescence from the chelate is captured with an image-intensified CCD camera. The choice of pulsed excitation source for TRFM has a large impact on the price and performance of the instrument. A flashlamp with a short pulse duration was selected for our instrument because of the high spectral energy in the UV region and short pulse length. However, flash output decays with an approximate lifetime of 18μs and the TRFM requires a long-lived chelate to ensure probe fluorescence is still visible after decay of the flash plasma. We synthesized a recently reported fluorescent chelate (BHHCT) and conjugated it to a monoclonal antibody directed against the water-borne parasite Giardia lamblia. Fluorescence lifetime of the construct was determined to be 339μs +/- 14μs and provided a 45-fold enhancement of labeled Giardia over background using a gate delay of 100μs. Despite the sub-optimal decay characteristics of the light pulse, flashlamps have many advantages compared to optical chopper wheels and modulated lasers. Their low cost, lack of vibration, ease of interface and small footprint are important factors to consider in TRFM design.
In Vivo Mitochondrial Oxygen Tension Measured by a Delayed Fluorescence Lifetime Technique
Mik, Egbert G.; Johannes, Tanja; Zuurbier, Coert J.; Heinen, Andre; Houben-Weerts, Judith H. P. M.; Balestra, Gianmarco M.; Stap, Jan; Beek, Johan F.; Ince, Can
2008-01-01
Mitochondrial oxygen tension (mitoPO2) is a key parameter for cellular function, which is considered to be affected under various pathophysiological circumstances. Although many techniques for assessing in vivo oxygenation are available, no technique for measuring mitoPO2 in vivo exists. Here we report in vivo measurement of mitoPO2 and the recovery of mitoPO2 histograms in rat liver by a novel optical technique under normal and pathological circumstances. The technique is based on oxygen-dependent quenching of the delayed fluorescence lifetime of protoporphyrin IX. Application of 5-aminolevulinic acid enhanced mitochondrial protoporphyrin IX levels and induced oxygen-dependent delayed fluorescence in various tissues, without affecting mitochondrial respiration. Using fluorescence microscopy, we demonstrate in isolated hepatocytes that the signal is of mitochondrial origin. The delayed fluorescence lifetime was calibrated in isolated hepatocytes and isolated perfused livers. Ultimately, the technique was applied to measure mitoPO2 in rat liver in vivo. The results demonstrate mitoPO2 values of ∼30–40 mmHg. mitoPO2 was highly sensitive to small changes in inspired oxygen concentration around atmospheric oxygen level. Ischemia-reperfusion interventions showed altered mitoPO2 distribution, which flattened overall compared to baseline conditions. The reported technology is scalable from microscopic to macroscopic applications, and its reliance on an endogenous compound greatly enhances its potential field of applications. PMID:18641065
NASA Technical Reports Server (NTRS)
Tuma, Margaret (Inventor); Gruhlke, Russell W. (Inventor)
1998-01-01
A detection method is integrated with a filtering method and an enhancement method to create a fluorescence sensor that can be miniaturized. The fluorescence sensor comprises a thin film geometry including a waveguide layer, a metal film layer and sensor layer. The thin film geometry of the fluorescence sensor allows the detection of fluorescent radiation over a narrow wavelength interval. This enables wavelength discrimination and eliminates the detection of unwanted light from unknown or spurious sources.
Mabood, F; Boqué, R; Folcarelli, R; Busto, O; Jabeen, F; Al-Harrasi, Ahmed; Hussain, J
2016-05-15
In this study the effect of thermal treatment on the enhancement of synchronous fluorescence spectroscopic method for discrimination and quantification of pure extra virgin olive oil (EVOO) samples from EVOO samples adulterated with refined oil was investigated. Two groups of samples were used. One group was analyzed at room temperature (25 °C) and the other group was thermally treated in a thermostatic water bath at 75 °C for 8h, in contact with air and with light exposure, to favor oxidation. All the samples were then measured with synchronous fluorescence spectroscopy. Synchronous fluorescence spectra were acquired by varying the wavelength in the region from 250 to 720 nm at 20 nm wavelength differential interval of excitation and emission. Pure and adulterated olive oils were discriminated by using partial least-squares discriminant analysis (PLS-DA). It was found that the best PLS-DA models were those built with the difference spectra (75 °C-25 °C), which were able to discriminate pure from adulterated oils at a 2% level of adulteration of refined olive oils. Furthermore, PLS regression models were also built to quantify the level of adulteration. Again, the best model was the one built with the difference spectra, with a prediction error of 3.18% of adulteration. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Mabood, F.; Boqué, R.; Folcarelli, R.; Busto, O.; Jabeen, F.; Al-Harrasi, Ahmed; Hussain, J.
2016-05-01
In this study the effect of thermal treatment on the enhancement of synchronous fluorescence spectroscopic method for discrimination and quantification of pure extra virgin olive oil (EVOO) samples from EVOO samples adulterated with refined oil was investigated. Two groups of samples were used. One group was analyzed at room temperature (25 °C) and the other group was thermally treated in a thermostatic water bath at 75 °C for 8 h, in contact with air and with light exposure, to favor oxidation. All the samples were then measured with synchronous fluorescence spectroscopy. Synchronous fluorescence spectra were acquired by varying the wavelength in the region from 250 to 720 nm at 20 nm wavelength differential interval of excitation and emission. Pure and adulterated olive oils were discriminated by using partial least-squares discriminant analysis (PLS-DA). It was found that the best PLS-DA models were those built with the difference spectra (75 °C-25 °C), which were able to discriminate pure from adulterated oils at a 2% level of adulteration of refined olive oils. Furthermore, PLS regression models were also built to quantify the level of adulteration. Again, the best model was the one built with the difference spectra, with a prediction error of 3.18% of adulteration.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, Alexander M.; Benson, Scott C.
1999-01-01
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, Alexander M.; Benson, Scott C.
1998-01-01
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, Alexander N.; Benson, Scott C.
1995-01-01
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, Alexander N.; Benson, Scott C.
1997-01-01
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated.
Zhuang, Qianfen; Cao, Wei; Ni, Yongnian; Wang, Yong
2018-08-01
Most of the conventional multidimensional differential sensors currently need at least two-step fabrication, namely synthesis of probe(s) and identification of multiple analytes by mixing of analytes with probe(s), and were conducted using multiple sensing elements or several devices. In the study, we chose five different nucleobases (adenine, cytosine, guanine, thymine, and uracil) as model analytes, and found that under hydrothermal conditions, sodium citrate could react directly with various nucleobases to yield different nitrogen-doped carbon nanodots (CDs). The CDs synthesized from different nucleobases exhibited different fluorescent properties, leading to their respective characteristic fluorescence spectra. Hence, we combined the fluorescence spectra of the CDs with advanced chemometrics like principle component analysis (PCA), hierarchical cluster analysis (HCA), K-nearest neighbor (KNN) and soft independent modeling of class analogy (SIMCA), to present a conceptually novel "synthesis-identification integration" strategy to construct a multidimensional differential sensor for nucleobase discrimination. Single-wavelength excitation fluorescence spectral data, single-wavelength emission fluorescence spectral data, and fluorescence Excitation-Emission Matrices (EEMs) of the CDs were respectively used as input data of the differential sensor. The results showed that the discrimination ability of the multidimensional differential sensor with EEM data set as input data was superior to those with single-wavelength excitation/emission fluorescence data set, suggesting that increasing the number of the data input could improve the discrimination power. Two supervised pattern recognition methods, namely KNN and SIMCA, correctly identified the five nucleobases with a classification accuracy of 100%. The proposed "synthesis-identification integration" strategy together with a multidimensional array of experimental data holds great promise in the construction of differential sensors. Copyright © 2018 Elsevier B.V. All rights reserved.
Multivariate optical element platform for compressed detection of fluorescence markers
NASA Astrophysics Data System (ADS)
Priore, Ryan J.; Swanstrom, Joseph A.
2014-05-01
The success of a commercial fluorescent diagnostic assay is dependent on the selection of a fluorescent biomarker; due to the broad nature of fluorescence biomarker emission profiles, only a small number of fluorescence biomarkers may be discriminated from each other as a function of excitation source. Multivariate Optical Elements (MOEs) are thin-film devices that encode a broad band, spectroscopic pattern allowing a simple broadband detector to generate a highly sensitive and specific detection for a target analyte. MOEs have historically been matched 1:1 to a discrete analyte or class prediction; however, MOE filter sets are capable of sensing projections of the original sparse spectroscopic space enabling a small set of MOEs to discriminate a multitude of target analytes. This optical regression can offer real-time measurements with relatively high signal-to-noise ratios that realize the advantages of multiplexed detection and pattern recognition in a simple optical instrument. The specificity advantage of MOE-based sensors allows fluorescent biomarkers that were once incapable of discrimination from one another via optical band pass filters to be employed in a common assay panel. A simplified MOE-based sensor may ultimately reduce the requirement for highly trained operators as well as move certain life science applications like disease prognostication from the laboratory to the point of care. This presentation will summarize the design and fabrication of compressed detection MOE filter sets for detecting multiple fluorescent biomarkers simultaneously with strong spectroscopic interference as well as comparing the detection performance of the MOE sensor with traditional optical band pass filter methodologies.
NASA Astrophysics Data System (ADS)
Mabood, Fazal; Boqué, Ricard; Folcarelli, Rita; Busto, Olga; Al-Harrasi, Ahmed; Hussain, Javid
2015-05-01
We have investigated the effect of thermal treatment on the discrimination of pure extra virgin olive oil (EVOO) samples from EVOO samples adulterated with sunflower oil. Two groups of samples were used. One group was analyzed at room temperature (25 °C) and the other group was thermally treated in a thermostatic water bath at 75 °C for 8 h, in contact with air and with light exposure, to favor oxidation. All samples were then measured with synchronous fluorescence spectroscopy. Fluorescence spectra were acquired by varying the excitation wavelength in the region from 250 to 720 nm. In order to optimize the differences between excitation and emission wavelengths, four constant differential wavelengths, i.e., 20 nm, 40 nm, 60 nm and 80 nm, were tried. Partial least-squares discriminant analysis (PLS-DA) was used to discriminate between pure and adulterated oils. It was found that the 20 nm difference was the optimal, at which the discrimination models showed the best results. The best PLS-DA models were those built with the difference spectra (75-25 °C), which were able to discriminate pure from adulterated oils at a 2% level of adulteration. Furthermore, PLS regression models were built to quantify the level of adulteration. Again, the best model was the one built with the difference spectra, with a prediction error of 1.75% of adulteration.
Quantifying fluorescence enhancement for slowly diffusing single molecules in plasmonic near fields
NASA Astrophysics Data System (ADS)
Caldarola, Martín; Pradhan, Biswajit; Orrit, Michel
2018-03-01
Gold nanorods are extensively used for single-molecule fluorescence enhancement as they are easy to synthesize, bio-compatible, and provide high light confinement at their nanometer-sized tips. The current way to estimate fluorescence enhancement relies on binned time traces or on fluorescence correlation spectroscopy. We report on novel ways to extract the enhancement factor in a single-molecule enhancement experiment, avoiding the arbitrary selection of one or a few high-intensity burst(s). These new estimates for the enhancement factor make use of the whole distribution of intensity bursts or of the interphoton delay distribution, which avoids the arbitrary binning of the fluorescence intensity time traces. We present experimental results on the bi-dimensional case, experimentally achieved using a lipid bilayer to support the diffusion of fluorophores. We support our findings with histograms of fluorescence bursts and with an analytical derivation of the interphoton delay distribution of (nearly) immobilized emitters from the fluorescence intensity profile.
Thermally activated delayed fluorescence organic dots for two-photon fluorescence lifetime imaging
NASA Astrophysics Data System (ADS)
He, Tingchao; Ren, Can; Li, Zhuohua; Xiao, Shuyu; Li, Junzi; Lin, Xiaodong; Ye, Chuanxiang; Zhang, Junmin; Guo, Lihong; Hu, Wenbo; Chen, Rui
2018-05-01
Autofluorescence is a major challenge in complex tissue imaging when molecules present in the biological tissue compete with the fluorophore. This issue may be resolved by designing organic molecules with long fluorescence lifetimes. The present work reports the two-photon absorption (TPA) properties of a thermally activated delayed fluorescence (TADF) molecule with carbazole as the electron donor and dicyanobenzene as the electron acceptor (i.e., 4CzIPN). The results indicate that 4CzIPN exhibits a moderate TPA cross-section (˜9 × 10-50 cm4 s photon-1), high fluorescence quantum yield, and a long fluorescence lifetime (˜1.47 μs). 4CzIPN was compactly encapsulated into an amphiphilic copolymer via nanoprecipitation to achieve water-soluble organic dots. Interestingly, 4CzIPN organic dots have been utilized in applications involving two-photon fluorescence lifetime imaging (FLIM). Our work aptly demonstrates that TADF molecules are promising candidates of nonlinear optical probes for developing next-generation multiphoton FLIM applications.
Discriminating Bio-aerosols from Non-Bio-aerosols in Real-Time by Pump-Probe Spectroscopy
Sousa, Gustavo; Gaulier, Geoffrey; Bonacina, Luigi; Wolf, Jean-Pierre
2016-01-01
The optical identification of bioaerosols in the atmosphere and its discrimination against combustion related particles is a major issue for real-time, field compatible instruments. In the present paper, we show that by embedding advanced pump-probe depletion spectroscopy schemes in a portable instrument, it is possible to discriminate amino acid containing airborne particles (bacteria, humic particles, etc.) from poly-cyclic aromatic hydrocarbon containing combustion particles (Diesel droplets, soot, vehicle exhausts) with high selectivity. Our real-time, multi-modal device provides, in addition to the pump-probe depletion information, fluorescence spectra (over 32 channels), fluorescence lifetime and Mie scattering patterns of each individually flowing particle in the probed air. PMID:27619546
Discriminating Bio-aerosols from Non-Bio-aerosols in Real-Time by Pump-Probe Spectroscopy
NASA Astrophysics Data System (ADS)
Sousa, Gustavo; Gaulier, Geoffrey; Bonacina, Luigi; Wolf, Jean-Pierre
2016-09-01
The optical identification of bioaerosols in the atmosphere and its discrimination against combustion related particles is a major issue for real-time, field compatible instruments. In the present paper, we show that by embedding advanced pump-probe depletion spectroscopy schemes in a portable instrument, it is possible to discriminate amino acid containing airborne particles (bacteria, humic particles, etc.) from poly-cyclic aromatic hydrocarbon containing combustion particles (Diesel droplets, soot, vehicle exhausts) with high selectivity. Our real-time, multi-modal device provides, in addition to the pump-probe depletion information, fluorescence spectra (over 32 channels), fluorescence lifetime and Mie scattering patterns of each individually flowing particle in the probed air.
Discriminating Bio-aerosols from Non-Bio-aerosols in Real-Time by Pump-Probe Spectroscopy.
Sousa, Gustavo; Gaulier, Geoffrey; Bonacina, Luigi; Wolf, Jean-Pierre
2016-09-13
The optical identification of bioaerosols in the atmosphere and its discrimination against combustion related particles is a major issue for real-time, field compatible instruments. In the present paper, we show that by embedding advanced pump-probe depletion spectroscopy schemes in a portable instrument, it is possible to discriminate amino acid containing airborne particles (bacteria, humic particles, etc.) from poly-cyclic aromatic hydrocarbon containing combustion particles (Diesel droplets, soot, vehicle exhausts) with high selectivity. Our real-time, multi-modal device provides, in addition to the pump-probe depletion information, fluorescence spectra (over 32 channels), fluorescence lifetime and Mie scattering patterns of each individually flowing particle in the probed air.
Cook, A; Pfeiffer, L-M; Thiele, S; Coenen, V A; Döbrössy, M D
2017-10-01
Major Depressive Disorder (MDD) is a heterogeneous psychiatric disorder with broad symptomatic manifestations. The current study examined, for the first time, olfactory memory and discrimination in the Flinders Sensitive Line (FSL) rodent model of depression. Male FSL rats and controls were trained on an Olfactory Discrimination (OD) and a Social Interaction (SI) test. On the OD test, the FSL and controls performed similarly at the shortest inter-trial interval (5min), however, with extended delay of 30min, the FSLs had a recall and odour discrimination deficit. At the longest delay (60min) both groups performed poorly. The FSL rats i.) had a deficit in olfactory discrimination suggesting impairment in olfactory memory and recall; ii.) were less likely to socialize with unfamiliar rats. The data suggests that FSL animals have an impaired olfactory information processing capacity. Copyright © 2017 Elsevier B.V. All rights reserved.
Prerequisite Skills That Support Learning through Video Modeling
ERIC Educational Resources Information Center
MacDonald, Rebecca P. F.; Dickson, Chata A.; Martineau, Meaghan; Ahearn, William H.
2015-01-01
The purpose of this study was to evaluate the relationship between tasks that require delayed discriminations such as delayed imitation and delayed matching to sample on acquisition of skills using video modeling. Twenty-nine participants with an ASD diagnosis were assessed on a battery of tasks including both immediate and delayed imitation and…
Kamitani, Toshiaki; Kuroiwa, Yoshiyuki
2009-01-01
Recent studies demonstrated an altered P3 component and prolonged reaction time during the visual discrimination tasks in multiple system atrophy (MSA). In MSA, however, little is known about the N2 component which is known to be closely related to the visual discrimination process. We therefore compared the N2 component as well as the N1 and P3 components in 17 MSA patients with these components in 10 normal controls, by using a visual selective attention task to color or to shape. While the P3 in MSA was significantly delayed in selective attention to shape, the N2 in MSA was significantly delayed in selective attention to color. N1 was normally preserved both in attention to color and in attention to shape. Our electrophysiological results indicate that the color discrimination process during selective attention is impaired in MSA.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, A.N.; Benson, S.C.
1997-07-08
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figs.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, A.M.; Benson, S.C.
1998-06-16
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figs.
DNA complexes with dyes designed for energy transfer as fluorescent markers
Glazer, A.N.; Benson, S.C.
1995-03-28
Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figures.
Odor Memory and Discrimination Covary as a Function of Delay between Encoding and Recall in Rats.
Hackett, Chelsea; Choi, Christina; O'Brien, Brenna; Shin, Philip; Linster, Christiane
2015-06-01
Nonassociative odor learning paradigms are often used to assess memory, social recognition and neuromodulation of olfactory pathways. We here use a modified object recognition paradigm to investigate how an important task parameter, delay between encoding and recall trials, affects the properties of this memory. We show that both memory for a previously investigated odorant and discrimination of a novel odorant decay with delay time and that rats can remember an odorant for up to 45min after a single trial encoding event. The number of odorants that can be encoded, as well as the specificity of the encoded memory, decrease with increased delay and also depend on stimulus concentration. Memory for an odorant and discrimination of a novel odorant decay at approximately the same rate, whereas the specificity of the formed memory decays faster than the memory itself. These results have important implications for the interpretation of behavioral data obtained with this paradigm. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Nachman, Paul; Pinnick, R. G.; Hill, Steven C.; Chen, Gang; Chang, Richard K.; Mayo, Michael W.; Fernandez, Gilbert L.
1996-03-01
We report the design and operation of a prototype conditional-sampling spectrograph detection system that can record the fluorescence spectra of individual, micrometer-sized aerosols as they traverse an intense 488-nm intracavity laser beam. The instrument's image-intensified CCD detector is gated by elastic scattering or by undispersed fluorescence from particles that enter the spectrograph's field of view. It records spectra only from particles with preselected scattering-fluorescence levels (a fiber-optic-photomultiplier subsystem provides the gating signal). This conditional-sampling procedure reduces data-handling rates and increases the signal-to-noise ratio by restricting the system's exposures to brief periods when aerosols traverse the beam. We demonstrate these advantages by reliably capturing spectra from individual fluorescent microspheres dispersed in an airstream. The conditional-sampling procedure also permits some discrimination among different types of particles, so that spectra may be recorded from the few interesting particles present in a cloud of background aerosol. We demonstrate such discrimination by measuring spectra from selected fluorescent microspheres in a mixture of two types of microspheres, and from bacterial spores in a mixture of spores and nonfluorescent kaolin particles.
Zhang, Xiao-Tai; Wang, Shu; Xing, Guo-Wen
2017-02-01
Ginsenoside is a large family of triterpenoid saponins from Panax ginseng, which possesses various important biological functions. Due to the very similar structures of these complex glycoconjugates, it is crucial to develop a powerful analytic method to identify ginsenosides qualitatively or quantitatively. We herein report an eight-channel fluorescent sensor array as artificial tongue to achieve the discriminative sensing of ginsenosides. The fluorescent cross-responsive array was constructed by four boronlectins bearing flexible boronic acid moieties (FBAs) with multiple reactive sites and two linear poly(phenylene-ethynylene) (PPEs). An "on-off-on" response pattern was afforded on the basis of superquenching of fluorescent indicator PPEs and an analyte-induced allosteric indicator displacement (AID) process. Most importantly, it was found that the canonical distribution of ginsenoside data points analyzed by linear discriminant analysis (LDA) was highly correlated with the inherent molecular structures of the analytes, and the absence of overlaps among the five point groups reflected the effectiveness of the sensor array in the discrimination process. Almost all of the unknown ginsenoside samples at different concentrations were correctly identified on the basis of the established mathematical model. Our current work provided a general and constructive method to improve the quality assessment and control of ginseng and its extracts, which are useful and helpful for further discriminating other complex glycoconjugate families.
Li, Ying; Liu, Weimin; Zhang, Panpan; Zhang, Hongyan; Wu, Jiasheng; Ge, Jiechao; Wang, Pengfei
2017-04-15
A fluorescent probe (1) for distinguishing amongst biothiols, including cysteine (Cys), homocysteine (Hcy) and glutathione (GSH), is developed based on different cascade reactions. The key design feature of fluorescent probe 1 is the integration of two potential reaction groups for the thiol and amino groups of biothiols in one molecule. By reacting with the halogen atom and α, β-unsaturated malonitrile in probe 1, Cys, Hcy and GSH can generate a total of three main products with distinct photophysical properties. Probe 1 shows a strong fluorescence turn-on response to Cys with blue-green emission by using an excitation wavelength of 390nm. At an excitation wavelength of 500nm, probe 1 responds to GSH over Cys and Hcy and emits strong orange fluorescence. The discrimination of biothiols can be demonstrated by cell imaging experiments, indicating that probe 1 can be a useful tool for the selective imaging of Cys and GSH in living cells. Copyright © 2016 Elsevier B.V. All rights reserved.
Nikolaenko, Andrey E; Cass, Michael; Bourcet, Florence; Mohamad, David; Roberts, Matthew
2015-11-25
Efficient intermonomer thermally activated delayed fluorescence is demonstrated for the first time, opening a new route to achieving high-efficiency solution processable polymer light-emitting device materials. External quantum efficiency (EQE) of up to 10% is achieved in a simple fully solution-processed device structure, and routes for further EQE improvement identified. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Stigma is Associated with Delays in Seeking Care Among HIV-Infected People in India
Steward, Wayne T.; Bharat, Shalini; Ramakrishna, Jayashree; Heylen, Elsa; Ekstrand, Maria L.
2012-01-01
Background Stigma shapes the lives of people living with HIV and may affect their willingness to seek medical care. But treatment delays can compromise health and increase the risk of transmission to others. Purpose To examine whether four stigma manifestations—enacted (discrimination), vicarious (hearing stories of discrimination), felt normative (perceptions of stigma’s prevalence) and internalized (personal endorsement of stigma beliefs)—were linked with delays in seeking care among HIV-infected people in India. Methods A cross-sectional survey was conducted with 961 HIV-positive men and women in Mumbai and Bengaluru. Results Enacted and internalized stigmas were correlated with delays in seeking care after testing HIV-positive. Depression symptoms mediated the associations of enacted and internalized stigmas with care seeking delays, whereas efforts to avoiding disclosing HIV status mediated only the association between internalized stigma and care seeking delays. Conclusions It is vital to develop stigma reduction interventions to ensure timely receipt of care. PMID:22282878
Mn(II)-coordinated Fluorescent Carbon Dots: Preparation and Discrimination of Organic Solvents
NASA Astrophysics Data System (ADS)
Wang, Yuru; Wang, Tianren; Chen, Xi; Xu, Yang; Li, Huanrong
2018-04-01
Herein, we prepared a Mn(II)-coordinated carbon dots (CDs) with fluorescence and MRI (magnetic resonance imaging) bimodal properties by a one-pot solvothermal method and separated via silica column chromatography. The quantum yield of the CDs increased greatly from 2.27% to 6.75% with increase of Mn(II) doping, meanwhile the CDs exhibited a higher MR activity (7.28 mM-1s-1) than that of commercial Gd-DTPA (4.63 mM-1s-1). In addition, white light emitting CDs were obtained by mixing the different types of CDs. Notably, these CDs exhibited different fluorescence emissions in different organic solvents and could be used to discriminate organic solvents based on the polarity and protonation of the solvents.
Portable spotter for fluorescent contaminants on surfaces
Schuresko, Daniel D.
1980-01-01
A portable fluorescence-based spotter for polynuclear aromatic hydrocarbon contamination on personnel and work area surfaces under ambient lighting conditions is provided. This instrument employs beam modulation and phase sensitive detection for discriminating between fluorescence from organic materials from reflected background light and inorganic fluorescent material. The device uses excitation and emission filters to provide differentiation between classes of aromatic organic compounds. Certain inorganic fluorescent materials, including heavy metal compounds, may also be distinguished from the organic compounds, despite both having similar optical properties.
Lee, Jiyoung; Aizawa, Naoya; Numata, Masaki; Adachi, Chihaya; Yasuda, Takuma
2017-01-01
Concentration quenching of thermally activated delayed fluorescence is found to be dominated by electron-exchange interactions, as described by the Dexter energy-transfer model. Owing to the short-range nature of the electron-exchange interactions, even a small modulation in the molecular geometric structure drastically affects the concentration-quenching, leading to enhanced solid-state photoluminescence and electroluminescence quantum efficiencies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Long wavelength fluorescence based biosensors for in vivo continuous monitoring of metabolites
NASA Astrophysics Data System (ADS)
Thomas, Joseph; Ambroise, Arounaguiry; Birchfield, Kara; Cai, Wensheng; Sandmann, Christian; Singh, Sarabjit; Weidemaier, Kristin; Pitner, J. Bruce
2006-02-01
The early stage development studies of novel implantable continuous metabolite sensor systems for glucose, lactate and fatty acids are discussed. These sensors utilize non-enzymatic "reagentless" sensor systems based on NIR fluorophore-labeled binding proteins. For in vivo applications, NIR fluorescence based systems (beyond 600 nm) have the added benefit of reduced interference from background scattering, tissue and serum absorption and cell auto-fluorescence. The long wavelength emission facilitates implanted sensor disks to transmit fluorescence to an external reader through wireless connections and the resulting fluorescence signals can be correlated to metabolite concentrations. We have developed a prototype optical system that uses a bifurcated optical fiber to transmit excitation and read emission at the surface of the skin. With this system, fluorescence signals were read over time through animal skin. The changes in glucose concentration were studied using immobilized sensor proteins and were compared to non-immobilized sensors in solution. For sensors in solution, no response delay was observed. For immobilized systems, the fluorescence response showed a delay corresponding to the diffusion time for the metabolite to equilibrate within the sensor.
2008-09-01
of up to 1000 individual boreholes is filled with 5000 to 10,000 lbs of material and delay fired over several seconds. The explosive array is...delay-fired mining events using seismic arrays : Application to the PDAR array in Wyoming, USA, Bull. Seism. Soc. Am. 97: pp .989–1001. Arrowsmith...regional seismic stations in monitoring areas of interest, particularly in countries where mining efforts are significant to the economy. As with other
Guo, Ting; Cui, Lei; Shen, Jiaoning; Wang, Rui; Zhu, Weiping; Xu, Yufang; Qian, Xuhong
2013-03-04
A novel dual-emission fluorescence probe has been developed for specific and sensitive detection of hypochlorite (ClO(-)). Upon addition of ClO(-), significant changes in fluorescence emission intensity at two discrete wavelengths were observed. Meanwhile OONO(-) led to only a single-channel fluorescence enhancement. This feature makes it a clear advantage in distinguishing ClO(-), RNS from other ROS.
Ntakatsane, M P; Yang, X Q; Lin, M; Liu, X M; Zhou, P
2011-11-01
Thirteen milk brands comprising 76 pasteurized and UHT milk samples of various compositions (whole, reduced fat, skimmed, low lactose, and high protein) were obtained from local supermarkets, and milk samples manufactured in various countries were discriminated using front-face fluorescence spectroscopy (FFFS) coupled with chemometric tools. The emission spectra of Maillard reaction products and riboflavin (MRP/RF; 400 to 600 nm) and tryptophan (300 to 400 nm) were recorded using FFFS, and the excitation wavelengths were set at 360 nm for MRP/RF and 290 nm for tryptophan. Principal component analysis (PCA) was applied to analyze the normalized spectra. The PCA of spectral information from MRP/RF discriminated the milk samples originating in different countries, and PCA of spectral information from tryptophan discriminated the samples according to composition. The fluorescence spectral data were compared with liquid chromatography-mass spectrometry results for the glycation extent of the milk samples, and a positive association (R(2)=0.84) was found between the degree of glycation of α-lactalbumin and the MRP/RF spectral data. This study demonstrates the ability and sensitivity of FFFS to rapidly discriminate and classify commercial milk with various compositions and processing conditions. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Zhu, Lixuan; Qing, Zhihe; Hou, Lina; Yang, Sheng; Zou, Zhen; Cao, Zhong; Yang, Ronghua
2017-08-25
As is well-known, the nucleic acid indicator-based strategy is one of the major approaches to monitor the nucleic acid hybridization-mediated recognition events in biochemical analysis, displaying obvious advantages including simplicity, low cost, convenience, and generality. However, conventional indicators either hold strong self-fluorescence or can be lighted by both ssDNA and dsDNA, lacking absolute selectivity for a certain conformation, always with high background interference and low sensitivity in sensing; and additional processing (e.g., nanomaterial-mediated background suppression, and enzyme-catalyzed signal amplification) is generally required to improve the detection performance. In this work, a carbazole derivative, EBCB, has been synthesized and screened as a dsDNA-specific fluorescent indicator. Compared with conventional indicators under the same conditions, EBCB displayed a much higher selective coefficient for dsDNA, with little self-fluorescence and negligible effect from ssDNA. Based on its superior capability in DNA conformation-discrimination, high sensitivity with minimizing background interference was demonstrated for direct detection of nucleic acid, and monitoring nucleic acid-based circuitry with good reversibity, resulting in low detection limit and high capability for discriminating base-mismatching. Thus, we expect that this highly specific DNA conformation-discriminating indicator will hold good potential for application in biochemical sensing and molecular logic switching.
NASA Astrophysics Data System (ADS)
Baria, E.; Cicchi, R.; Nesi, G.; Massi, D.; Pavone, F. S.
2017-07-01
We combined Second Harmonic Generation, Two-Photon Fluorescence and Fluorescence Lifetime Imaging Microscopy for studying human carotid ex vivo tissue sections affected by atherosclerosis, resulting in the discrimination of different arterial regions within the plaques.
Cui, Lin-Song; Deng, Ya-Li; Tsang, Daniel Ping-Kuen; Jiang, Zuo-Quan; Zhang, Qisheng; Liao, Liang-Sheng; Adachi, Chihaya
2016-09-01
Efficient sky-blue organic light-emitting diodes (OLEDs) employing thermally activated delayed fluorescence (TADF) display a three orders of magnitude increase in lifetime, which is superior to those of controlled phosphorescent OLEDs used in this study. The combination of electro-oxidation and photo-oxidation of the TADF emitters in their triplet excited-states is suppressed through molecule design and device engineering. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Insausti, Matías; Gomes, Adriano A; Cruz, Fernanda V; Pistonesi, Marcelo F; Araujo, Mario C U; Galvão, Roberto K H; Pereira, Claudete F; Band, Beatriz S F
2012-08-15
This paper investigates the use of UV-vis, near infrared (NIR) and synchronous fluorescence (SF) spectrometries coupled with multivariate classification methods to discriminate biodiesel samples with respect to the base oil employed in their production. More specifically, the present work extends previous studies by investigating the discrimination of corn-based biodiesel from two other biodiesel types (sunflower and soybean). Two classification methods are compared, namely full-spectrum SIMCA (soft independent modelling of class analogies) and SPA-LDA (linear discriminant analysis with variables selected by the successive projections algorithm). Regardless of the spectrometric technique employed, full-spectrum SIMCA did not provide an appropriate discrimination of the three biodiesel types. In contrast, all samples were correctly classified on the basis of a reduced number of wavelengths selected by SPA-LDA. It can be concluded that UV-vis, NIR and SF spectrometries can be successfully employed to discriminate corn-based biodiesel from the two other biodiesel types, but wavelength selection by SPA-LDA is key to the proper separation of the classes. Copyright © 2012 Elsevier B.V. All rights reserved.
Multicolor Super-Resolution Fluorescence Imaging via Multi-Parameter Fluorophore Detection
Bates, Mark; Dempsey, Graham T; Chen, Kok Hao; Zhuang, Xiaowei
2012-01-01
Understanding the complexity of the cellular environment will benefit from the ability to unambiguously resolve multiple cellular components, simultaneously and with nanometer-scale spatial resolution. Multicolor super-resolution fluorescence microscopy techniques have been developed to achieve this goal, yet challenges remain in terms of the number of targets that can be simultaneously imaged and the crosstalk between color channels. Herein, we demonstrate multicolor stochastic optical reconstruction microscopy (STORM) based on a multi-parameter detection strategy, which uses both the fluorescence activation wavelength and the emission color to discriminate between photo-activatable fluorescent probes. First, we obtained two-color super-resolution images using the near-infrared cyanine dye Alexa 750 in conjunction with a red cyanine dye Alexa 647, and quantified color crosstalk levels and image registration accuracy. Combinatorial pairing of these two switchable dyes with fluorophores which enhance photo-activation enabled multi-parameter detection of six different probes. Using this approach, we obtained six-color super-resolution fluorescence images of a model sample. The combination of multiple fluorescence detection parameters for improved fluorophore discrimination promises to substantially enhance our ability to visualize multiple cellular targets with sub-diffraction-limit resolution. PMID:22213647
Time resolved fluorescence of cow and goat milk powder
NASA Astrophysics Data System (ADS)
Brandao, Mariana P.; de Carvalho dos Anjos, Virgílio; Bell., Maria José V.
2017-01-01
Milk powder is an international dairy commodity. Goat and cow milk powders are significant sources of nutrients and the investigation of the authenticity and classification of milk powder is particularly important. The use of time-resolved fluorescence techniques to distinguish chemical composition and structure modifications could assist develop a portable and non-destructive methodology to perform milk powder classification and determine composition. This study goal is to differentiate milk powder samples from cows and goats using fluorescence lifetimes. The samples were excited at 315 nm and the fluorescence intensity decay registered at 468 nm. We observed fluorescence lifetimes of 1.5 ± 0.3, 6.4 ± 0.4 and 18.7 ± 2.5 ns for goat milk powder; and 1.7 ± 0.3, 6.9 ± 0.2 and 29.9 ± 1.6 ns for cow's milk powder. We discriminate goat and cow powder milk by analysis of variance using Fisher's method. In addition, we employed quadratic discriminant analysis to differentiate the milk samples with accuracy of 100%. Our results suggest that time-resolved fluorescence can provide a new method to the analysis of powder milk and its composition.
Clement, T S; Feltus, J R; Kaiser, D H; Zentall, T R
2000-03-01
Stimuli associated with less effort or with shorter delays to reinforcement are generally preferred over those associated with greater effort or longer delays to reinforcement. However, the opposite appears to be true of stimuli that follow greater effort or longer delays. In training, a simple simultaneous discrimination followed a single peck to an initial stimulus (S+FR1 S-FR1) and a different simple simultaneous discrimination followed 20 pecks to the initial stimulus (S+FR20 S-FR20). On test trials, pigeons preferred S+FR20 over S+FR1 and S-FR20 over S-FR1. These data support the view that the state of the animal immediately prior to presentation of the discrimination affects the value of the reinforcement that follows it. This contrast effect is analogous to effects that when they occur in humans have been attributed to more complex cognitive and social factors.
Hyperspectral imaging fluorescence excitation scanning for colon cancer detection
NASA Astrophysics Data System (ADS)
Leavesley, Silas J.; Walters, Mikayla; Lopez, Carmen; Baker, Thomas; Favreau, Peter F.; Rich, Thomas C.; Rider, Paul F.; Boudreaux, Carole W.
2016-10-01
Optical spectroscopy and hyperspectral imaging have shown the potential to discriminate between cancerous and noncancerous tissue with high sensitivity and specificity. However, to date, these techniques have not been effectively translated to real-time endoscope platforms. Hyperspectral imaging of the fluorescence excitation spectrum represents new technology that may be well suited for endoscopic implementation. However, the feasibility of detecting differences between normal and cancerous mucosa using fluorescence excitation-scanning hyperspectral imaging has not been evaluated. The goal of this study was to evaluate the initial feasibility of using fluorescence excitation-scanning hyperspectral imaging for measuring changes in fluorescence excitation spectrum concurrent with colonic adenocarcinoma using a small pre-pilot-scale sample size. Ex vivo analysis was performed using resected pairs of colorectal adenocarcinoma and normal mucosa. Adenocarcinoma was confirmed by histologic evaluation of hematoxylin and eosin (H&E) permanent sections. Specimens were imaged using a custom hyperspectral imaging fluorescence excitation-scanning microscope system. Results demonstrated consistent spectral differences between normal and cancerous tissues over the fluorescence excitation range of 390 to 450 nm that could be the basis for wavelength-dependent detection of colorectal cancers. Hence, excitation-scanning hyperspectral imaging may offer an alternative approach for discriminating adenocarcinoma from surrounding normal colonic mucosa, but further studies will be required to evaluate the accuracy of this approach using a larger patient cohort.
NASA Astrophysics Data System (ADS)
Pu, Yang; Sordillo, Laura A.; Alfano, Robert R.
2015-03-01
Native fluorescence spectroscopy offers an important role in cancer discrimination. It is widely acknowledged that the emission spectrum of tissue is a superposition of spectra of various salient fluorophores. In this study, the native fluorescence spectra of human cancerous and normal breast tissues excited by selected wavelength of 300 nm are used to investigate the key building block fluorophores: tryptophan and reduced nicotinamide adenine dinucleotide (NADH). The basis spectra of these key fluorophores' contribution to the tissue emission spectra are obtained by nonnegative constraint analysis. The emission spectra of human cancerous and normal tissue samples are projected onto the fluorophore spectral subspace. Since previous studies indicate that tryptophan and NADH are key fluorophores related with tumor evolution, it is essential to obtain their information from tissue fluorescence but discard the redundancy. To evaluate the efficacy of for cancer detection, linear discriminant analysis (LDA) classifier is used to evaluate the sensitivity, and specificity. This research demonstrates that the native fluorescence spectroscopy measurements are effective to detect changes of fluorophores' compositions in tissues due to the development of cancer.
NASA Astrophysics Data System (ADS)
Fan, Qimeng; Chen, Chaoyin; Huang, Zaiqiang; Zhang, Chunmei; Liang, Pengjuan; Zhao, Shenglan
2015-02-01
Rhizoma Gastrodiae (Tianma) of different variants and different geographical origins has vital difference in quality and physiological efficacy. This paper focused on the classification and identification of Tianma of six types (two variants from three different geographical origins) using three dimensional synchronous fluorescence spectroscopy (3D-SFS) coupled with principal component analysis (PCA). 3D-SF spectra of aqueous extracts, which were obtained from Tianma of the six types, were measured by a LS-50B luminescence spectrofluorometer. The experimental results showed that the characteristic fluorescent spectral regions of the 3D-SF spectra were similar, while the intensities of characteristic regions are different significantly. Coupled these differences in peak intensities with PCA, Tianma of six types could be discriminated successfully. In conclusion, 3D-SFS coupled with PCA, which has such advantages as effective, specific, rapid, non-polluting, has an edge for discrimination of the similar Chinese herbal medicine. And the proposed methodology is a useful tool to classify and identify Tianma of different variants and different geographical origins.
ERIC Educational Resources Information Center
Wilson, Jacqueline Z.; Marks, Genee; Noone, Lynne; Hamilton-Mackenzie, Jennifer
2010-01-01
This paper examines indirect discrimination in Australian universities that tends to obstruct and delay women's academic careers. The topic is defined and contextualised via a 1998 speech by the Australian Human Rights Commission's Sex Discrimination Commissioner, juxtaposed with a brief contemporaneous exemplar. The paper discusses the prevalence…
Fluorescence Behavioral Imaging (FBI) Tracks Identity in Heterogeneous Groups of Drosophila
Ramdya, Pavan; Schaffter, Thomas; Floreano, Dario; Benton, Richard
2012-01-01
Distinguishing subpopulations in group behavioral experiments can reveal the impact of differences in genetic, pharmacological and life-histories on social interactions and decision-making. Here we describe Fluorescence Behavioral Imaging (FBI), a toolkit that uses transgenic fluorescence to discriminate subpopulations, imaging hardware that simultaneously records behavior and fluorescence expression, and open-source software for automated, high-accuracy determination of genetic identity. Using FBI, we measure courtship partner choice in genetically mixed groups of Drosophila. PMID:23144871
Fluorescence behavioral imaging (FBI) tracks identity in heterogeneous groups of Drosophila.
Ramdya, Pavan; Schaffter, Thomas; Floreano, Dario; Benton, Richard
2012-01-01
Distinguishing subpopulations in group behavioral experiments can reveal the impact of differences in genetic, pharmacological and life-histories on social interactions and decision-making. Here we describe Fluorescence Behavioral Imaging (FBI), a toolkit that uses transgenic fluorescence to discriminate subpopulations, imaging hardware that simultaneously records behavior and fluorescence expression, and open-source software for automated, high-accuracy determination of genetic identity. Using FBI, we measure courtship partner choice in genetically mixed groups of Drosophila.
Molindone: effects in pigeons responding under conditional discrimination tasks.
Picker, M J; Cleary, J P; Berens, K; Oliveto, A H; Dykstra, L A
1989-02-01
Pigeons were trained to respond under three conditional discrimination procedures; 1) a fixed-consecutive-number procedure with (FCN 8-SD) and without (FCN 8) an added external discriminative stimulus, 2) a delayed matching-to-sample (DMTS) procedure using 0-sec, 2-sec and 8-sec delay intervals, and 3) a repeated acquisition of behavioral chains (RA) procedure using a four-link response chain with three stimulus keys. The atypical neuroleptic agent molindone decreased accuracy under the FCN 8 at doses that had no effect on accuracy under the FCN 8-SD. Under the DMTS procedure, molindone-induced decreases in accuracy were directly related to the delay interval, with the largest relative decrements obtained at the 8-sec delay and the smallest at the 0-sec delay. Under the RA procedure, molindone decreased accuracy at doses that had little or no effect on the number of correct responses emitted. Relative to control values, molindone-induced decreases in accuracy were smallest under the DMTS and FCN 8-SD procedures and largest under the FCN 8 and RA procedures. The differential effects obtained with molindone under each of these procedures illustrate the need to employ a variety of assays when determining the behavioral actions of neuroleptics. In addition, this battery of behavioral tests may provide a useful tool for assessing the different neurochemical actions of neuroleptic compounds.
NASA Astrophysics Data System (ADS)
Insausti, Matías; de Araújo Gomes, Adriano; Camiña, José Manuel; de Araújo, Mario Cesar Ugulino; Band, Beatriz Susana Fernández
2017-03-01
The present work proposes the use of total synchronous fluorescence spectroscopy (TSFS) as a discrimination methodology for fluorescent compounds in edible oils, which are preserved after the transesterification processes in the biodiesel production. In the same way, a similar study is presented to identify fluorophores that do not change in expired vegetal oils, to associate physicochemical parameters to fluorescent measures, as contribution to a fingerprint for increasing the chemical knowledge of these products. The fluorescent fingerprints were obtained by Tucker3 decomposition of a three-way array of the total synchronous fluorescence matrices. This chemometric method presents the ability for modeling non-bilinear data, as Total Synchronous Fluorescence Spectra data, and consists in the decomposition of the three way data arrays (samples × Δλ × λ excitation), into four new data matrices: A (scores), B (profile in Δλ mode), C (profile in spectra mode) and G (relationships between A, B and C). In this study, 50 samples of oil from soybean, corn and sunflower seeds before and after its expiration time, as well as 50 biodiesel samples obtained by transesterification of the same oils were measured by TSFS. This study represents an immediate application of chemical fingerprint for the discrimination of non-expired and expired edible oils and biodiesel. This method does not require the use of reagents or laborious procedures for the chemical characterization of samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hertz, P.R.
Fluorescence spectroscopy is a highly sensitive and selective tool for the analysis of complex systems. In order to investigate the efficacy of several steady state and dynamic techniques for the analysis of complex systems, this work focuses on two types of complex, multicomponent samples: petrolatums and coal liquids. It is shown in these studies dynamic, fluorescence lifetime-based measurements provide enhanced discrimination between complex petrolatum samples. Additionally, improved quantitative analysis of multicomponent systems is demonstrated via incorporation of organized media in coal liquid samples. This research provides the first systematic studies of (1) multifrequency phase-resolved fluorescence spectroscopy for dynamic fluorescence spectralmore » fingerprinting of complex samples, and (2) the incorporation of bile salt micellar media to improve accuracy and sensitivity for characterization of complex systems. In the petroleum studies, phase-resolved fluorescence spectroscopy is used to combine spectral and lifetime information through the measurement of phase-resolved fluorescence intensity. The intensity is collected as a function of excitation and emission wavelengths, angular modulation frequency, and detector phase angle. This multidimensional information enhances the ability to distinguish between complex samples with similar spectral characteristics. Examination of the eigenvalues and eigenvectors from factor analysis of phase-resolved and steady state excitation-emission matrices, using chemometric methods of data analysis, confirms that phase-resolved fluorescence techniques offer improved discrimination between complex samples as compared with conventional steady state methods.« less
NASA Astrophysics Data System (ADS)
Rothe, C.; Pålsson, L. O.; Monkman, A. P.
2002-12-01
The luminescence emitted from pure and benzil-doped thin films of the conjugated polymer polyfluorene [PF2/6] are compared. The prompt fluorescence from the first singlet-excited state of the polymer is quenched by 90% in the presence of 10% per weight benzil. In addition to the prompt fluorescence, time-resolved spectroscopy at low temperature also allows the detection of phosphorescence and delayed fluorescence from the host polymer. Again the delayed fluorescence is strongly quenched but the phosphorescence is enhanced in doped samples. An explanation of the results is given in terms of singlet energy transfer from the host to benzil and triplet energy transfer from the dopant back to PF2/6. We have applied this to enable better understanding of the photophysics in PF2/6 doped with a platinum porphyrin complex.
Development of Fluorescent Protein Probes Specific for Parallel DNA and RNA G-Quadruplexes.
Dang, Dung Thanh; Phan, Anh Tuân
2016-01-01
We have developed fluorescent protein probes specific for parallel G-quadruplexes by attaching cyan fluorescent protein to the G-quadruplex-binding motif of the RNA helicase RHAU. Fluorescent probes containing RHAU peptide fragments of different lengths were constructed, and their binding to G-quadruplexes was characterized. The selective recognition and discrimination of G-quadruplex topologies by the fluorescent protein probes was easily detected by the naked eye or by conventional gel imaging. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fluorescence lifetime in cardiovascular diagnostics
NASA Astrophysics Data System (ADS)
Marcu, Laura
2010-01-01
We review fluorescence lifetime techniques including time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and fluorescence lifetime imaging microscopy (FLIM) instrumentation and associated methodologies that allow for characterization and diagnosis of atherosclerotic plaques. Emphasis is placed on the translational research potential of TR-LIFS and FLIM and on determining whether intrinsic fluorescence signals can be used to provide useful contrast for the diagnosis of high-risk atherosclerotic plaque. Our results demonstrate that these techniques allow for the discrimination of important biochemical features involved in atherosclerotic plaque instability and rupture and show their potential for future intravascular applications.
Fluorescence lifetime in cardiovascular diagnostics.
Marcu, Laura
2010-01-01
We review fluorescence lifetime techniques including time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and fluorescence lifetime imaging microscopy (FLIM) instrumentation and associated methodologies that allow for characterization and diagnosis of atherosclerotic plaques. Emphasis is placed on the translational research potential of TR-LIFS and FLIM and on determining whether intrinsic fluorescence signals can be used to provide useful contrast for the diagnosis of high-risk atherosclerotic plaque. Our results demonstrate that these techniques allow for the discrimination of important biochemical features involved in atherosclerotic plaque instability and rupture and show their potential for future intravascular applications.
Photonic reagents for concentration measurement of flu-orescent proteins with overlapping spectra
NASA Astrophysics Data System (ADS)
Goun, Alexei; Bondar, Denys I.; Er, Ali O.; Quine, Zachary; Rabitz, Herschel A.
2016-05-01
By exploiting photonic reagents (i.e., coherent control by shaped laser pulses), we employ Optimal Dynamic Discrimination (ODD) as a novel means for quantitatively characterizing mixtures of fluorescent proteins with a large spectral overlap. To illustrate ODD, we simultaneously measured concentrations of in vitro mixtures of Enhanced Blue Fluorescent Protein (EBFP) and Enhanced Cyan Fluorescent Protein (ECFP). Building on this foundational study, the ultimate goal is to exploit the capabilities of ODD for parallel monitoring of genetic and protein circuits by suppressing the spectral cross-talk among multiple fluorescent reporters.
Kim, Byungyeon; Park, Byungjun; Lee, Seungrag; Won, Youngjae
2016-01-01
We demonstrated GPU accelerated real-time confocal fluorescence lifetime imaging microscopy (FLIM) based on the analog mean-delay (AMD) method. Our algorithm was verified for various fluorescence lifetimes and photon numbers. The GPU processing time was faster than the physical scanning time for images up to 800 × 800, and more than 149 times faster than a single core CPU. The frame rate of our system was demonstrated to be 13 fps for a 200 × 200 pixel image when observing maize vascular tissue. This system can be utilized for observing dynamic biological reactions, medical diagnosis, and real-time industrial inspection. PMID:28018724
NASA Astrophysics Data System (ADS)
Cha, Jae-Ryung; Gong, Myoung-Seon; Lee, Tak Jae; Ha, Tae Hoon; Lee, Chil Won
2018-04-01
The ortho-substituted donor-acceptor molecules 2-(4,6-diphenyl-1, 3, 5-triazin-2-yl)- N,Ndiphenylaniline (DPA- o-Trz) and 2-(4,6-diphenyl-1, 3, 5-triazine-2-yl)- N,N-di- p-tolylaniline (MPA- o-Trz) were designed, synthesized, and found to exhibit green fluorescence characteristics. Notably, the singlet-triplet energy gap was less than 0.1 eV, indicating that reverse intersystem crossing gave rise to thermally activated delayed fluorescence (TADF). The organic light-emitting device performance of MPA- o-Trz showed a high external quantum efficiency of 16.3% and good color stability from 0.1 cd/m2 to 5000 cd/m2.
Meier, Jeremy D; Xie, Hongtao; Sun, Yang; Sun, Yinghua; Hatami, Nisa; Poirier, Brian; Marcu, Laura; Farwell, D Gregory
2010-06-01
The objectives of this study were to 1) determine differences in lifetime fluorescence between normal and malignant tissue of the upper aerodigestive tract, and 2) evaluate the potential of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) as a diagnostic instrument for head and neck squamous cell carcinoma (HNSCC). Cross-sectional study. University-based medical center. Nine patients with suspected HNSCC were included. In the operating room, a nitrogen pulse laser (337 nm, 700-picosecond pulse width) was used to induce tissue autofluorescence of normal tissue and suspected malignant lesions. Spectral intensities and time-domain measurements were obtained and compared with the histopathology at each site. A total of 53 sites were measured. The fluorescence parameters that provided the most discrimination were determined. Differences in spectral intensities allowed for discrimination between malignant and normal tissue. The spectral intensity of malignant tissue was lower than that of normal tissue, and a shift of peak intensity to a longer wavelength was observed in the normalized spectrum of malignant tissue in the range of 360 to approximately 660 nm. Multiple time-resolved fluorescence parameters provided the best diagnostic discrimination between normal tissue and carcinoma, including average lifetimes (i.e., at 390 nm: 1.7 +/- 0.06 ns [not significant] for normal and 1.3 +/- 0.06 ns for tumor, P = 0.0025) and the second-order Laguerre expansion coefficient (LEC-2) (i.e., at 460 nm: 0.135 +/- 0.001 for normal and 0.155 +/- 0.007 for tumor, P < 0.05). These findings highlight some of the differences in lifetime fluorescence between normal and malignant tissue. TR-LIFS has potential as a noninvasive diagnostic technique for HNSCC. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.
Meier, Jeremy D.; Xie, Hongtao; Sun, Yang; Sun, Yinghua; Hatami, Nisa; Poirier, Brian; Marcu, Laura; Farwell, D. Gregory
2011-01-01
OBJECTIVE 1) Determine differences in lifetime fluorescence between normal and malignant tissue of the upper aerodigestive tract. 2) Evaluate the potential of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) as a diagnostic instrument for head and neck squamous cell carcinoma (HNSCC). STUDY DESIGN Cross-sectional study. SETTING University-based medical center. SUBJECTS AND METHODS Nine patients with suspected HNSCC were included. In the operating room, a nitrogen pulse laser (337 nm, 700 ps pulse width) was used to induce tissue autofluorescence of normal tissue and suspected malignant lesions. Spectral intensities and time-domain measurements were obtained and compared to the histopathology at each site. A total of 53 sites were measured. The fluorescence parameters that provided the most discrimination were determined. RESULTS Differences in spectral intensities allowed for discrimination between malignant and normal tissue. The spectral intensity of malignant tissue was lower than the normal tissue, and a shift of peak intensity to a longer wavelength was observed in the normalized spectrum of malignant tissue in the range of 360~660 nm. Multiple time-resolved fluorescence parameters provided the best diagnostic discrimination between normal tissue and carcinoma, including average lifetimes (i.e., at 390 nm: 1.7±0.06 ns for normal and 1.3±0.06 ns for tumor, P=0.0025), and the Laguerre coefficients, LEC-2 (i.e., at 460 nm: 0.135±0.001 for normal and 0.155±0.007 for tumor, P<0.05). CONCLUSION These findings highlight some of the differences in lifetime fluorescence between normal and malignant tissue. TR-LIFS has potential as a non-invasive diagnostic technique for HNSCC. PMID:20493355
Jiao, Zhe; Zhang, Pengfei; Chen, Hongwei; Li, Jingwen; Zhong, Zhengquan; Fan, Hongbo; Cheng, Faliang
2018-10-05
Halobenzoquinones (HBQs) were reported as disinfection byproducts (DBPs) which had potential risk of bladder cancer. In this paper, a highly selective analytical method for HBQs was developed by HBQs-mediated assembly of amino acid modified Mn-doped ZnS/Quantum Dots (Mn: ZnS QDs). In the presence HBQs, a charge-transfer complex (CTC) was formed between aromatic rings of HBQs and the primary amino groups on the surface of the QDs. The formation of CTC led to the aggregation of QDs, as a result fluorescence decreasing occurred. The decrease was correlated with the concentration of HBQs. Then a fluorescence sensor array for discrimination of three kinds of HBQs including 2,6-Dichloro-1,4-benzoquinone (DCBQ), 2,6-Dibromo-1,4-benzoquinone (DBBQ) and 2,3,6-trichloro-1,4-benzoquinone (TCBQ) was developed. Four kinds of amino acids including cysteine, threonine, tyrosine and tryptophan were embellished on the Mn: ZnS QDs. The different extents of aggregation led to different fluorescence decreasing effect, thus distinct fluorescence patterns were created. It showed that three kinds of HBQs could be discriminated successfully by fluorescence sensor array at a range of concentrations through principal component analysis (PCA). The unknown samples were predicted by with a stepwise linear discriminant analysis (SLDA) using Mahalanobis distance as a selection criterion with accuracy of 100%. Remarkably, the practicability of the proposed sensor array was further validated by identification of three kinds of HBQs at different concentrations in real drinking water samples. Compared to LC/MS/MS, this fluorescent sensor array-based method was proved to be more convenient since the nanoparticles can be prepared flexibly according to the property of the target. Copyright © 2018 Elsevier B.V. All rights reserved.
Sakamoto, Toshiro; Endo, Shogo
2013-01-01
Previous studies have shown that deep cerebellar nuclei (DCN)-lesioned mice develop conditioned responses (CR) on delay eyeblink conditioning when a salient tone conditioned stimulus (CS) is used, which suggests that the cerebellum potentially plays a role in more complicated cognitive functions. In the present study, we examined the role of DCN in tone frequency discrimination in the delay eyeblink-conditioning paradigm. In the first experiment, DCN-lesioned and sham-operated mice were subjected to standard simple eyeblink conditioning under low-frequency tone CS (LCS: 1 kHz, 80 dB) or high-frequency tone CS (HCS: 10 kHz, 70 dB) conditions. DCN-lesioned mice developed CR in both CS conditions as well as sham-operated mice. In the second experiment, DCN-lesioned and sham-operated mice were subjected to two-tone discrimination tasks, with LCS+ (or HCS+) paired with unconditioned stimulus (US), and HCS− (or LCS−) without US. CR% in sham-operated mice increased in LCS+ (or HCS+) trials, regardless of tone frequency of CS, but not in HCS− (or LCS−) trials. The results indicate that sham-operated mice can discriminate between LCS+ and HCS− (or HCS+ and LCS−). In contrast, DCN-lesioned mice showed high CR% in not only LCS+ (or HCS+) trials but also HCS− (or LCS−) trials. The results indicate that DCN lesions impair the discrimination between tone frequency in eyeblink conditioning. Our results suggest that the cerebellum plays a pivotal role in the discrimination of tone frequency. PMID:23555821
Liu, Xiao-Ke; Chen, Zhan; Qing, Jian; Zhang, Wen-Jun; Wu, Bo; Tam, Hoi Lam; Zhu, Furong; Zhang, Xiao-Hong; Lee, Chun-Sing
2015-11-25
A high-performance hybrid white organic light-emitting device (WOLED) is demonstrated based on an efficient novel thermally activated delayed fluorescence (TADF) blue exciplex system. This device shows a low turn-on voltage of 2.5 V and maximum forward-viewing external quantum efficiency of 25.5%, which opens a new avenue for achieving high-performance hybrid WOLEDs with simple structures. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Jinfeng; Chen, Wencheng; Chen, Rui; Liu, Xiao-Ke; Xiong, Yuan; Kershaw, Stephen V; Rogach, Andrey L; Adachi, Chihaya; Zhang, Xiaohong; Lee, Chun-Sing
2016-09-27
We applied organic nanostructures based on thermally activated delayed fluorescent (TADF) emitters for singlet oxygen generation. Due to the extremely small energy gaps between the excited singlet states (S 1 ) and triplet states (T 1 ) of these heavy-metal-free organic nanostructures, intersystem conversion between S 1 and T 1 can occur easily. This strategy also works well for exciplex-type TADF emitters prepared by mixing suitable donors and acceptors which have no TADF characteristics themselves.
NASA Astrophysics Data System (ADS)
Vasefi, Fartash; Kittle, David S.; Nie, Zhaojun; Falcone, Christina; Patil, Chirag G.; Chu, Ray M.; Mamelak, Adam N.; Black, Keith L.; Butte, Pramod V.
2016-04-01
We have developed and tested a system for real-time intra-operative optical identification and classification of brain tissues using time-resolved fluorescence spectroscopy (TRFS). A supervised learning algorithm using linear discriminant analysis (LDA) employing selected intrinsic fluorescence decay temporal points in 6 spectral bands was employed to maximize statistical significance difference between training groups. The linear discriminant analysis on in vivo human tissues obtained by TRFS measurements (N = 35) were validated by histopathologic analysis and neuronavigation correlation to pre-operative MRI images. These results demonstrate that TRFS can differentiate between normal cortex, white matter and glioma.
NASA Astrophysics Data System (ADS)
Crawford, I.; Ruske, S.; Topping, D. O.; Gallagher, M. W.
2015-07-01
In this paper we present improved methods for discriminating and quantifying Primary Biological Aerosol Particles (PBAP) by applying hierarchical agglomerative cluster analysis to multi-parameter ultra violet-light induced fluorescence (UV-LIF) spectrometer data. The methods employed in this study can be applied to data sets in excess of 1×106 points on a desktop computer, allowing for each fluorescent particle in a dataset to be explicitly clustered. This reduces the potential for misattribution found in subsampling and comparative attribution methods used in previous approaches, improving our capacity to discriminate and quantify PBAP meta-classes. We evaluate the performance of several hierarchical agglomerative cluster analysis linkages and data normalisation methods using laboratory samples of known particle types and an ambient dataset. Fluorescent and non-fluorescent polystyrene latex spheres were sampled with a Wideband Integrated Bioaerosol Spectrometer (WIBS-4) where the optical size, asymmetry factor and fluorescent measurements were used as inputs to the analysis package. It was found that the Ward linkage with z-score or range normalisation performed best, correctly attributing 98 and 98.1 % of the data points respectively. The best performing methods were applied to the BEACHON-RoMBAS ambient dataset where it was found that the z-score and range normalisation methods yield similar results with each method producing clusters representative of fungal spores and bacterial aerosol, consistent with previous results. The z-score result was compared to clusters generated with previous approaches (WIBS AnalysiS Program, WASP) where we observe that the subsampling and comparative attribution method employed by WASP results in the overestimation of the fungal spore concentration by a factor of 1.5 and the underestimation of bacterial aerosol concentration by a factor of 5. We suggest that this likely due to errors arising from misatrribution due to poor centroid definition and failure to assign particles to a cluster as a result of the subsampling and comparative attribution method employed by WASP. The methods used here allow for the entire fluorescent population of particles to be analysed yielding an explict cluster attribution for each particle, improving cluster centroid definition and our capacity to discriminate and quantify PBAP meta-classes compared to previous approaches.
NASA Astrophysics Data System (ADS)
Suhandy, D.; Yulia, M.
2018-03-01
Indonesia is one of the important producers of several specialty coffees, which have a particularly high economic value, including Civet coffee (‘kopi luwak’ in Indonesian language) and Peaberry coffee (‘kopi lanang’ in Indonesian language). The production of Civet and Peaberry coffee is very limited. In order to provide authentication of Civet and Peaberry coffee and protect consumers from adulteration, a robust and easy method for evaluating ground Civet and Peaberry coffee and detection of its adulteration is needed. In this study, we investigate the use of fluorescence spectroscopy combined with SIMCA (soft independent modelling of class analogies) method to discriminate three Indonesian specialty coffee: ground Peaberry, Civet and Pagar Alam coffee. Total 90 samples were used (30 samples for Civet, Peaberry and Pagar Alam coffee, respectively). All coffee samples were ground using a home-coffee-grinder. Since particle size in coffee powder has a significant influence on the spectra obtained, we sieved all coffee samples through a nest of U. S. standard sieves (mesh number of 40) on a Meinzer II sieve shaker for 10 minutes to obtain a particle size of 420 µm. The experiments were performed at room temperature (around 27-29°C). All samples were extracted with distilled water and then filtered. For each samples, 3 mL of extracted sample then was pipetted into 10 mm cuvettes for spectral data acquisition. The EEM (excitation-emission matrix) spectral data of coffee samples were acquired using JASCO FP-8300 Fluorescence Spectrometer. The principal component analysis (PCA) result shows that it is possible to discriminate types of coffee based on information from EEM (excitation-emission matrix) spectral data. Using SIMCA method, the discrimination model of Indonesian specialty coffee was successfully developed and resulted in high performance of discrimination with 100% of sensitivity and specificity for Peaberry, Civet and Pagar Alam coffee. This research has opened the possibility to develop a promising method to detect and evaluate authentication of Indonesian specialty coffees using fluorescence spectroscopy.
NASA Astrophysics Data System (ADS)
Baniya, S.; Pang, Z.; Sun, D.; Basel, T.; Zhai, Y.; Kwon, O.; Choi, H.; Vardeny, Z. V.
2016-09-01
A new type of organic light-emitting diode (OLED) has emerged that shows enhanced operational stability and large internal quantum efficiency approaching 100%, which is based on exciplexes in donor-acceptor (D-A) blends having thermally activated delayed fluorescence (TADF) when doped with fluorescent emitters. We have investigated magnetoelectroluminescence (MEL) and magneto-conductivity in such TADF-based OLEDs, as well as magnetophotoluminescence (MPL) in thin films based on the OLEDs active layers, with various fluorescence emitters. We found that both MEL and MPL responses are thermally activated with substantially lower activation energy compared to that in the pristine undoped D-A exciplex host blend. In addition, both MPL and MEL steeply decrease with the emitters' concentration. This indicates the existence of a loss mechanism, whereby the triplet charge-transfer state in the D-A exciplex host blend may directly decay to the lowest, non-emissive triplet state of the additive fluorescent emitter molecules.
NASA Astrophysics Data System (ADS)
Zanello, Marc; Poulon, Fanny; Pallud, Johan; Varlet, Pascale; Hamzeh, H.; Abi Lahoud, Georges; Andreiuolo, Felipe; Ibrahim, Ali; Pages, Mélanie; Chretien, Fabrice; di Rocco, Federico; Dezamis, Edouard; Nataf, François; Turak, Baris; Devaux, Bertrand; Abi Haidar, Darine
2017-02-01
Delineating tumor margins as accurately as possible is of primordial importance in surgical oncology: extent of resection is associated with survival but respect of healthy surrounding tissue is necessary for preserved quality of life. The real-time analysis of the endogeneous fluorescence signal of brain tissues is a promising tool for defining margins of brain tumors. The present study aims to demonstrate the feasibility of multimodal optical analysis to discriminate fresh samples of gliomas, metastases and meningiomas from their appropriate controls. Tumor samples were studied on an optical fibered endoscope using spectral and fluorescence lifetime analysis and then on a multimodal set-up for acquiring spectral, one and two-photon fluorescence images, second harmonic generation signals and two-photon fluorescence lifetime datasets. The obtained data allowed us to differentiate healthy samples from tumor samples. These results confirmed the possible clinical relevance of this real-time multimodal optical analysis. This technique can be easily applied to neurosurgical procedures for a better delineation of surgical margins.
Trimodal spectra for high discrimination of benign and malignant prostate tissue
NASA Astrophysics Data System (ADS)
Al Salhi, Mohamad; Masilamani, Vadivel; Trinka, Vijmasi; Rabah, Danny; Al Turki, Mohammed R.
2011-02-01
High false positives and over diagnosis is a major problem with management of prostate cancer. A non-invasive or a minimally invasive technique to accurately distinguish malignant prostate cancers from benign tumors will be extremely helpful to overcome this problem. In this paper, we had used three different fluorescence spectroscopy techniques viz., Fluorescence Emission Spectrum (FES), Stokes' Shift Spectrum (SSS) and Reflectance Spectrum (RS) to discriminate benign prostate tumor tissues (N=12) and malignant prostate cancer tissues (N=8). These fluorescence techniques were used to determine the relative concentration of naturally occurring biomolecules such as tryptophan, elastin, NADH and flavin which are found to be out of proportion in cancer tissues. Our studies show that combining all three techniques, benign and malignant prostate tissues could be classified with accuracy greater than 90%. This preliminary report is based on in vitro spectroscopy analysis. However, by employing fluorescence endoscopy techniques, this can be extended to in vivo analysis as well. This technique has the potential to identify malignant prostate tissues without surgery.
Liu, Li; Fan, Yao; Fu, Haiyan; Chen, Feng; Ni, Chuang; Wang, Jinxing; Yin, Qiaobo; Mu, Qingling; Yang, Tianming; She, Yuanbin
2017-04-22
Fluorescent "turn-off" sensors based on water-soluble quantum dots (QDs) have drawn increasing attention owing to their unique properties such as high fluorescence quantum yields, chemical stability and low toxicity. In this work, a novel method based on the fluorescence "turn-off" model with water-soluble CdTe QDs as the fluorescent probes for differentiation of 29 different famous green teas is established. The fluorescence of the QDs can be quenched in different degrees in light of positions and intensities of the fluorescent peaks for the green teas. Subsequently, with aid of classic partial least square discriminant analysis (PLSDA), all the green teas can be discriminated with high sensitivity, specificity and a satisfactory recognition rate of 100% for training set and 98.3% for prediction set, respectively. Especially, the "turn-off" fluorescence PLSDA model based on second-order derivatives (2nd der) with reduced least complexity (LVs = 3) was the most effective one for modeling. Most importantly, we further demonstrated the established "turn-off" fluorescent sensor mode has several significant advantages and appealing properties over the conventional fluorescent method for large-class-number classification (LCNC) of green teas. This work is, to the best of our knowledge, the first report on the rapid and effective identification of so many kinds of famous green teas based on the "turn-off" model of QDs combined with chemometrics, which also implies other potential applications on complex LCNC classification system with weak fluorescence or even without fluorescence to achieve higher detective response and specificity. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bashtanov, M. E.; Drozdova, N. N.; Krasnovskii, A. A.
1999-12-01
An investigation was made of the ratios of the intensity Idf of the singlet-oxygen(1O2)-sensitised delayed fluorescence of the zinc complex of tetra(4-tert-butyl)phthalocyanine (ZnTBPc), with the maximum at λ = 685 nm, to the intensity I1270 of the photosensitised phosphorescence of 1O2 with the maximum at λ = 1270 nm in deuterated benzene when excited with λ = 337 nm nitrogen-laser pulses. Depending on the energy density of the laser radiation (0.25 — 0.7 mJ cm-2) and on the concentration of ZnTBPc (0.06 — 3.4 μM), the ratio of the zero-time intensities of the delayed fluorescence of ZnTBPc and of the singlet-oxygen phosphorescence Idf0/I12700 varied from 0.01 to 0.2 in air-saturated solutions of ZnTBPc. The intensity Idf0 decreased fivefold as a result of saturation with oxygen of air-saturated solutions. The quantum efficiency of the delayed fluorescence was represented by the coefficient α =(Idf0/I12700)kr/(γf[1O2]0[ZnTBPc]), where [1O2]0 is the zero-time concentration of 1O2 after a laser shot; kr is the rate constant of radiative deactivation of 1O2 in the investigated solvent; γf is the quantum yield of the ZnTBPc fluorescence. It was established that in the case of air-saturated solutions of ZnTBPc this coefficient was approximately 200 times less than for metal-free tetra(4-tert-butyl)phthalocyanine and its absolute value was ~2 × 1011 M-2 s-1.
The NSLS 100 element solid state array detector
Furenlid, L.R.; Kraner, H.W.; Rogers, L.C.; Cramer, S.P.; Stephani, D.; Beuttenmuller, R.H.; Beren, J.
2015-01-01
X-ray absorption studies of dilute samples require fluorescence detection techniques. Since signal-to-noise ratios are governed by the ratio of fluorescent to scattered photons counted by a detector, solid state detectors which can discriminate between fluorescence and scattered photons have become the instruments of choice for trace element measurements. Commercially available 13 element Ge array detectors permitting total count rates < 500000 counts per second are now in routine use. Since X-ray absorption beamlines at high brightness synchrotron sources can already illuminate most dilute samples with enough flux to saturate the current generation of solid state detectors, the development of next-generation instruments with significantly higher total count rates is essential. We present the design and current status of the 100 element Si array detector being developed in a collaboration between the NSLS and the Instrumentation Division at Brookhaven National Laboratory. The detecting array consists of a 10×10 matrix of 4 mm×4 mm elements laid out on a single piece of ultrahigh purity silicon mounted at the front end of a liquid nitrogen dewar assembly. A matrix of charge sensitive integrating preamplifiers feed signals to an array of shaping amplifiers, single channel analyzers, and scalers. An electronic switch, delay amplifier, linear gate, digital scope, peak sensing A/D converter, and histogramining memory module provide for complete diagnostics and channel calibration. The entire instrument is controlled by a LabView 2 application on a MacII ci; the software also provides full control over beamline hardware and performs the data collection. PMID:26722135
NASA Astrophysics Data System (ADS)
Kim, Dae-Hyeon; D'Aléo, Anthony; Chen, Xian-Kai; Sandanayaka, Atula D. S.; Yao, Dandan; Zhao, Li; Komino, Takeshi; Zaborova, Elena; Canard, Gabriel; Tsuchiya, Youichi; Choi, Eunyoung; Wu, Jeong Weon; Fages, Frédéric; Brédas, Jean-Luc; Ribierre, Jean-Charles; Adachi, Chihaya
2018-02-01
Near-infrared organic light-emitting diodes and semiconductor lasers could benefit a variety of applications including night-vision displays, sensors and information-secured displays. Organic dyes can generate electroluminescence efficiently at visible wavelengths, but organic light-emitting diodes are still underperforming in the near-infrared region. Here, we report thermally activated delayed fluorescent organic light-emitting diodes that operate at near-infrared wavelengths with a maximum external quantum efficiency of nearly 10% using a boron difluoride curcuminoid derivative. As well as an effective upconversion from triplet to singlet excited states due to the non-adiabatic coupling effect, this donor-acceptor-donor compound also exhibits efficient amplified spontaneous emission. By controlling the polarity of the active medium, the maximum emission wavelength of the electroluminescence spectrum can be tuned from 700 to 780 nm. This study represents an important advance in near-infrared organic light-emitting diodes and the design of alternative molecular architectures for photonic applications based on thermally activated delayed fluorescence.
Xiong, Xiaoqing; Song, Fengling; Wang, Jingyun; Zhang, Yukang; Xue, Yingying; Sun, Liangliang; Jiang, Na; Gao, Pan; Tian, Lu; Peng, Xiaojun
2014-07-09
Compared with fluorescence imaging utilizing fluorophores whose lifetimes are in the order of nanoseconds, time-resolved fluorescence microscopy has more advantages in monitoring target fluorescence. In this work, compound DCF-MPYM, which is based on a fluorescein derivative, showed long-lived luminescence (22.11 μs in deaerated ethanol) and was used in time-resolved fluorescence imaging in living cells. Both nanosecond time-resolved transient difference absorption spectra and time-correlated single-photon counting (TCSPC) were employed to explain the long lifetime of the compound, which is rare in pure organic fluorophores without rare earth metals and heavy atoms. A mechanism of thermally activated delayed fluorescence (TADF) that considers the long wavelength fluorescence, large Stokes shift, and long-lived triplet state of DCF-MPYM was proposed. The energy gap (ΔEST) of DCF-MPYM between the singlet and triplet state was determined to be 28.36 meV by the decay rate of DF as a function of temperature. The ΔE(ST) was small enough to allow efficient intersystem crossing (ISC) and reverse ISC, leading to efficient TADF at room temperature. The straightforward synthesis of DCF-MPYM and wide availability of its starting materials contribute to the excellent potential of the compound to replace luminescent lanthanide complexes in future time-resolved imaging technologies.
Abdelhalim, Mohamed Anwar K.; Moussa, Sherif A. Abdelmottaleb; AL-Mohy, Yanallah Hussain
2013-01-01
Background. In this study, we examined whether UV-visible and fluorescence spectroscopy techniques detect the progression of atherosclerosis in serum of rabbits fed on high-cholesterol diet (HCD) and HCD supplemented with zinc (HCD + Zn) compared with the control. Methods. The control rabbits group was fed on 100 g/day of normal diet. The HCD group was fed on Purina Certified Rabbit Chow supplemented with 1.0% cholesterol plus 1.0% olive oil (100 g/day) for the same period. The HCD + Zn group was fed on normal Purina Certified Rabbit Chow plus 1.0% cholesterol and 1.0% olive oil supplemented with 470 ppm Zn for the same feeding period. UV-visible and fluorescence spectroscopy and biochemistry in Rabbit's blood serum and blood hematology were measured in Rabbit's blood. Results. We found that the fluorescent peak of HCD shifted toward UV-visible wavelength compared with the control using fluorescent excitation of serum at 192 nm. In addition, they showed that supplementation of zinc (350 ppm) restored the fluorescent peak closely to the control. By using UV-visible spectroscopy approach, we found that the peak absorbance of HCD (about 280 nm) was higher than that of control and that zinc supplementation seemed to decrease the absorbance. Conclusions. This study demonstrates that ultraviolet-visible and fluorescence spectroscopy techniques can be applied as noninvasive techniques on a sample blood serum for diagnosing or detecting the progression of atherosclerosis. The Zn supplementation to rabbits fed on HCD delays or retards the progression of atherosclerosis. Inducing anemia in rabbits fed on HCD delays the progression of atherosclerosis. PMID:24350281
A temporal discriminability account of children's eyewitness suggestibility.
Bright-Paul, Alexandra; Jarrold, Christopher
2009-07-01
Children's suggestibility is typically measured using a three-stage 'event-misinformation-test' procedure. We examined whether suggestibility is influenced by the time delays imposed between these stages, and in particular whether the temporal discriminability of sources (event and misinformation) predicts performance. In a novel approach, the degree of source discriminability was calculated as the relative magnitude of two intervals (the ratio of event-misinformation and misinformation-test intervals), based on an adaptation of existing 'ratio-rule' accounts of memory. Five-year-olds (n =150) watched an event, and were exposed to misinformation, before memory for source was tested. The absolute event-test delay (12 versus 24 days) and the 'ratio' of event-misinformation/misinformation-test intervals (11:1, 3:1, 1:1, 1:3 and 1:11) were manipulated across participants. The temporal discriminability of sources, measured by the ratio, was indeed a strong predictor of suggestibility. Most importantly, if the ratio was constant (e.g. 18/6 versus 9/3 days), performance was remarkably similar despite variations in absolute delay (e.g. 24 versus 12 days). This intriguing finding not only extends the ratio-rule of distinctiveness to misinformation paradigms, but also serves to illustrate a new empirical means of differentiating between explanations of suggestibility based on interference between sources and disintegration of source information over time.
NASA Astrophysics Data System (ADS)
Su, Rongguo; Chen, Xiaona; Wu, Zhenzhen; Yao, Peng; Shi, Xiaoyong
2015-07-01
The feasibility of using fluorescence excitation-emission matrix (EEM) along with parallel factor analysis (PARAFAC) and nonnegative least squares (NNLS) method for the differentiation of phytoplankton taxonomic groups was investigated. Forty-one phytoplankton species belonging to 28 genera of five divisions were studied. First, the PARAFAC model was applied to EEMs, and 15 fluorescence components were generated. Second, 15 fluorescence components were found to have a strong discriminating capability based on Bayesian discriminant analysis (BDA). Third, all spectra of the fluorescence component compositions for the 41 phytoplankton species were spectrographically sorted into 61 reference spectra using hierarchical cluster analysis (HCA), and then, the reference spectra were used to establish a database. Finally, the phytoplankton taxonomic groups was differentiated by the reference spectra database using the NNLS method. The five phytoplankton groups were differentiated with the correct discrimination ratios (CDRs) of 100% for single-species samples at the division level. The CDRs for the mixtures were above 91% for the dominant phytoplankton species and above 73% for the subdominant phytoplankton species. Sixteen of the 85 field samples collected from the Changjiang River estuary were analyzed by both HPLC-CHEMTAX and the fluorometric technique developed. The results of both methods reveal that Bacillariophyta was the dominant algal group in these 16 samples and that the subdominant algal groups comprised Dinophyta, Chlorophyta and Cryptophyta. The differentiation results by the fluorometric technique were in good agreement with those from HPLC-CHEMTAX. The results indicate that the fluorometric technique could differentiate algal taxonomic groups accurately at the division level.
Hyperspectral imaging fluorescence excitation scanning for colon cancer detection
Leavesley, Silas J.; Walters, Mikayla; Lopez, Carmen; Baker, Thomas; Favreau, Peter F.; Rich, Thomas C.; Rider, Paul F.; Boudreaux, Carole W.
2016-01-01
Abstract. Optical spectroscopy and hyperspectral imaging have shown the potential to discriminate between cancerous and noncancerous tissue with high sensitivity and specificity. However, to date, these techniques have not been effectively translated to real-time endoscope platforms. Hyperspectral imaging of the fluorescence excitation spectrum represents new technology that may be well suited for endoscopic implementation. However, the feasibility of detecting differences between normal and cancerous mucosa using fluorescence excitation-scanning hyperspectral imaging has not been evaluated. The goal of this study was to evaluate the initial feasibility of using fluorescence excitation-scanning hyperspectral imaging for measuring changes in fluorescence excitation spectrum concurrent with colonic adenocarcinoma using a small pre-pilot-scale sample size. Ex vivo analysis was performed using resected pairs of colorectal adenocarcinoma and normal mucosa. Adenocarcinoma was confirmed by histologic evaluation of hematoxylin and eosin (H&E) permanent sections. Specimens were imaged using a custom hyperspectral imaging fluorescence excitation-scanning microscope system. Results demonstrated consistent spectral differences between normal and cancerous tissues over the fluorescence excitation range of 390 to 450 nm that could be the basis for wavelength-dependent detection of colorectal cancers. Hence, excitation-scanning hyperspectral imaging may offer an alternative approach for discriminating adenocarcinoma from surrounding normal colonic mucosa, but further studies will be required to evaluate the accuracy of this approach using a larger patient cohort. PMID:27792808
Mercury speciation with fluorescent gold nanocluster as a probe.
Yang, Jian-Yu; Yang, Ting; Wang, Xiao-Yan; Chen, Ming-Li; Yu, Yong-Liang; Wang, Jian-Hua
2018-05-11
Fluorescent nanoparticles are widely used for sensing biologically significant species. However, it is rarely reported for the discrimination or speciation of metal species. In this work, we report for the first time the speciation of mercury (Hg 2+ ) and methylmercury (CH 3 Hg + ) by taking advantage of the fluorescence feature of folic acid-capped gold nanoclusters (FA-AuNCs). FA-Au NCs exhibit an average size of 2.08±0.15 nm and a maximum emission at λ ex /λ em = 280/440 nm with a quantum yield of 27.3%. It is interesting that Hg 2+ causes a significant quench on the fluorescence of FA-Au NCs, whereas CH 3 Hg + leads to a remarkable fluorescence enhancement. Based on this discriminative fluorescent response between Hg 2+ and CH 3 Hg + , a novel nanosensor for the speciation of CH 3 Hg + and Hg 2+ was developed, providing limits of detection (LOD) of 28 nM for Hg 2+ and 25 nM for CH 3 Hg + within 100-1000 nM. This sensing system is highly selective to mercury. Its practical applications were further demonstrated by the analysis of CH 3 Hg + and the speciation of mercury (CH 3 Hg + and Hg 2+ ) in environmental water and fish samples.
NASA Astrophysics Data System (ADS)
Gao, Ying; Pan, Qing-Qing; Zhao, Liang; Geng, Yun; Su, Tan; Gao, Ting; Su, Zhong-Min
2018-06-01
To seek effective thermally activated delayed fluorescence (TADF) molecules, we have designed compounds 1-4 by introducing substituents on the para-position of boron atom of blue TADF molecule (DABNA-1). The results indicate that 1-4 not only retain the blue emission from 454 to 466 nm, but also possess larger oscillator strength. Besides, the fluorescence radiative rates (kr) of 1-4 are higher than that of DABNA-1. The singlet-triplet energy splitting (ΔΕST) values of designed compounds are smaller than that of DABNA-1. Taking both ΔΕST and kr into account, designed compounds show better TADF performances, indicating their potential as TADF materials.
Fluorescence lifetime in cardiovascular diagnostics
Marcu, Laura
2010-01-01
We review fluorescence lifetime techniques including time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and fluorescence lifetime imaging microscopy (FLIM) instrumentation and associated methodologies that allow for characterization and diagnosis of atherosclerotic plaques. Emphasis is placed on the translational research potential of TR-LIFS and FLIM and on determining whether intrinsic fluorescence signals can be used to provide useful contrast for the diagnosis of high-risk atherosclerotic plaque. Our results demonstrate that these techniques allow for the discrimination of important biochemical features involved in atherosclerotic plaque instability and rupture and show their potential for future intravascular applications. PMID:20210432
Photonic reagents for concentration measurement of flu-orescent proteins with overlapping spectra
Goun, Alexei; Bondar, Denys I.; Er, Ali O.; Quine, Zachary; Rabitz, Herschel A.
2016-01-01
By exploiting photonic reagents (i.e., coherent control by shaped laser pulses), we employ Optimal Dynamic Discrimination (ODD) as a novel means for quantitatively characterizing mixtures of fluorescent proteins with a large spectral overlap. To illustrate ODD, we simultaneously measured concentrations of in vitro mixtures of Enhanced Blue Fluorescent Protein (EBFP) and Enhanced Cyan Fluorescent Protein (ECFP). Building on this foundational study, the ultimate goal is to exploit the capabilities of ODD for parallel monitoring of genetic and protein circuits by suppressing the spectral cross-talk among multiple fluorescent reporters. PMID:27181496
NASA Astrophysics Data System (ADS)
Carestia, Mariachiara; Pizzoferrato, Roberto; Gelfusa, Michela; Cenciarelli, Orlando; Ludovici, Gian Marco; Gabriele, Jessica; Malizia, Andrea; Murari, Andrea; Vega, Jesus; Gaudio, Pasquale
2015-11-01
Biosecurity and biosafety are key concerns of modern society. Although nanomaterials are improving the capacities of point detectors, standoff detection still appears to be an open issue. Laser-induced fluorescence of biological agents (BAs) has proved to be one of the most promising optical techniques to achieve early standoff detection, but its strengths and weaknesses are still to be fully investigated. In particular, different BAs tend to have similar fluorescence spectra due to the ubiquity of biological endogenous fluorophores producing a signal in the UV range, making data analysis extremely challenging. The Universal Multi Event Locator (UMEL), a general method based on support vector regression, is commonly used to identify characteristic structures in arrays of data. In the first part of this work, we investigate fluorescence emission spectra of different simulants of BAs and apply UMEL for their automatic classification. In the second part of this work, we elaborate a strategy for the application of UMEL to the discrimination of different BAs' simulants spectra. Through this strategy, it has been possible to discriminate between these BAs' simulants despite the high similarity of their fluorescence spectra. These preliminary results support the use of SVR methods to classify BAs' spectral signatures.
Schweitzer, Dietrich; Gaillard, Elizabeth R; Dillon, James; Mullins, Robert F; Russell, Stephen; Hoffmann, Birgit; Peters, Sven; Hammer, Martin; Biskup, Christoph
2012-06-08
Time and spectrally resolved measurements of autofluorescence have the potential to monitor metabolism at the cellular level. Fluorophores that emit with the same fluorescence intensity can be discriminated from each other by decay time of fluorescence intensity after pulsed excitation. We performed time-resolved autofluorescence measurements on fundus samples from a donor with significant extramacular drusen. Tissue sections from two human donors were prepared and imaged with a laser scanning microscope. The sample was excited with a titanium-sapphire laser, which was tuned to 860 nm, and frequency doubled by a BBO crystal to 430 nm. The repetition rate was 76 MHz and the pulse width was 170 femtoseconds (fs). The time-resolved autofluorescence was recorded simultaneously in 16 spectral channels (445-605 nm) and bi-exponentially fitted. RPE can be discriminated clearly from Bruch's membrane, drusen, and choroidal connective tissue by fluorescence lifetime. In RPE, bright fluorescence of lipofuscin could be detected with a maximum at 510 nm and extending beyond 600 nm. The lifetime was 385 ps. Different types of drusen were found. Most of them did not contain lipofuscin and exhibited a weak fluorescence, with a maximum at 470 nm. The lifetime was 1785 picoseconds (ps). Also, brightly emitting lesions, presumably representing basal laminar deposits, with fluorescence lifetimes longer than those recorded in RPE could be detected. The demonstrated differentiation of fluorescent structures by their fluorescence decay time is important for interpretation of in vivo measurements by the new fluorescence lifetime imaging (FLIM) ophthalmoscopy on healthy subjects as well as on patients.
Liu, Xiao-Ke; Chen, Zhan; Zheng, Cai-Jun; Liu, Chuan-Lin; Lee, Chun-Sing; Li, Fan; Ou, Xue-Mei; Zhang, Xiao-Hong
2015-04-08
High-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes based on exciplex emitters are demonstrated. The best device, based on a TAPC:DPTPCz emitter, shows a high external quantum efficiency of 15.4%. Strategies for predicting and designing efficient exciplex emitters are also provided. This approach allow prediction and design of efficient exciplex emitters for achieving high-efficiency organic light-emitting diodes, for future use in displays and lighting applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Green-emitting MADF complex for OLED applications
NASA Astrophysics Data System (ADS)
Klimes, Kody; Zhu, Zhi-Qiang; Holloway, Sean; Li, Jian
2016-09-01
In this article, we demonstrated an exceptional palladium complex that exhibits both phosphorescence and delayed fluorescence for use as an efficient emitter in OLEDs. Devices employing PdN3N achieved external quantum efficiencies in excess of 22% and remarkable device operational lifetime to 90% initial luminance estimated at over 30,000 h at a practical luminance of 100 cd/m2. Further tuning of the phosphorescent and delayed fluorescent emission should have a great impact in the development of efficient and stable emitters for deep blue or white OLEDs.
NASA Astrophysics Data System (ADS)
Mayer, Michael; Nattress, Jason; Barhoumi Meddeb, Amira; Foster, Albert; Trivelpiece, Cory; Rose, Paul; Erickson, Anna; Ounaies, Zoubeida; Jovanovic, Igor
2015-10-01
Detection of shielded special nuclear material is crucial to countering nuclear terrorism and proliferation, but its detection is challenging. By observing the emission of delayed neutrons, which is a unique signature of nuclear fission, the presence of nuclear material can be inferred. We report on the observation of delayed neutrons from natural uranium by using monoenergetic photons and neutrons to induce fission. An interrogating beam of 4.4 MeV and 15.1 MeV gamma-rays and neutrons was produced using the 11B(d,n-γ)12C reaction and used to probe different targets. Neutron detectors with complementary Cherenkov detectors then discriminate material undergoing fission. A Li-doped glass-polymer composite neutron detector was used, which displays excellent n/ γ discrimination even at low energies, to observe delayed neutrons from uranium fission. Delayed neutrons have relatively low energies (~0.5 MeV) compared to prompt neutrons, which makes them difficult to detect using recoil-based detectors. Neutrons were counted and timed after the beam was turned off to observe the characteristic decaying time profile of delayed neutrons. The expected decay of neutron emission rate is in agreement with the common parametrization into six delayed neutron groups.
Zhang, Dongdong; Song, Xiaozeng; Cai, Minghan; Duan, Lian
2018-02-01
Organic light-emitting diodes (OLEDs) based on thermally activated delayed fluorescence-sensitized fluorescence (TSF) offer the possibility of attaining an ultimate high efficiency with low roll-off utilizing noble-metal free, easy-to-synthesize, pure organic fluorescent emitters. However, the performances of TSF-OLEDs are still unsatisfactory. Here, TSF-OLEDs with breakthrough efficiencies even at high brightnesses by suppressing the competitive deactivation processes, including direct charge recombination on conventional fluorescent dopants (CFDs) and Dexter energy transfer from the host to the CFDs, are demonstrated. On the one hand, electronically inert terminal-substituents are introduced to protect the electronically active core of the CFDs; on the other hand, delicate device structures are designed to provide multiple energy-funneling paths. As a result, unprecedentedly high maximum external quantum efficiency/power efficiency of 24%/71.4 lm W -1 in a green TSF-OLED are demonstrated, which remain at 22.6%/52.3 lm W -1 even at a high luminance of 5000 cd m -2 . The work unlocks the potential of TSF-OLEDs, paving the way toward practical applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Piffaretti, Filippo M.; Santhakumar, Kanappan; Forte, Eddy; van den Bergh, Hubert E.; Wagnières, Georges A.
2011-03-01
A new optical-fiber-based spectrofluorometer for in vivo or in vitro detection of delayed fluorescence is presented and characterized. This compact setup is designed so that it can be readily adapted for future clinical use. Optical excitation is done with a nitrogen laser-pumped, tunable dye laser, emitting in the UV-vis part of the spectrum. Excitation and luminescence signals are carried to and from the biological tissues under investigation, located out of the setup enclosure, by a single optical fiber. These measurements, as well as measurements performed without a fiber on in vitro samples in a thermostable quartz cell, in a controlled-atmosphere enclosure, are possible due to the efficient collection of the laser-induced luminescence light which is collected and focused on the detector with a high aperture parabolic mirror. The detection is based on a gated photomultiplier which allows for time-resolved measurements of the delayed fluorescence intensity. Thus, relevant luminescence lifetimes, typically in the sub-microsecond-to-millisecond range, can be measured with near total rejection of the sample's prompt fluorescence. The instrument spectral and temporal resolution, as well as its sensitivity, is characterized and measurement examples are presented. The primary application foreseen for this setup is the monitoring and adjustment of the light dose delivered during photodynamic therapy.
Airborne particulate discriminator
Creek, Kathryn Louise [San Diego, CA; Castro, Alonso [Santa Fe, NM; Gray, Perry Clayton [Los Alamos, NM
2009-08-11
A method and apparatus for rapid and accurate detection and discrimination of biological, radiological, and chemical particles in air. A suspect aerosol of the target particulates is treated with a taggant aerosol of ultrafine particulates. Coagulation of the taggant and target particles causes a change in fluorescent properties of the cloud, providing an indication of the presence of the target.
A Temporal Discriminability Account of Children's Eyewitness Suggestibility
ERIC Educational Resources Information Center
Bright-Paul, Alexandra; Jarrold, Christopher
2009-01-01
Children's suggestibility is typically measured using a three-stage "event-misinformation-test" procedure. We examined whether suggestibility is influenced by the time delays imposed between these stages, and in particular whether the temporal discriminability of sources (event and misinformation) predicts performance. In a novel approach, the…
ERIC Educational Resources Information Center
Arntzen, Erik
2006-01-01
The present series of 4 experiments investigated the probability of responding in accord with equivalence in adult human participants as a function of increasing or decreasing delays in a many-to-one (MTO) or comparison-as-node and one-to-many (OTM) or sample-as-node conditional discrimination procedure. In Experiment 1, 12 participants started…
ERIC Educational Resources Information Center
Vandewalle, Ellen; Boets, Bart; Ghesquiere, Pol; Zink, Inge
2012-01-01
Purpose: To compare the development of phonological skills in children with specific language impairment (SLI) with and without literacy delay and to examine whether kindergarten phonological skills could discriminate these 2 groups. Method: In a longitudinal study, 8 children with SLI and literacy delay, 10 children with SLI and normal literacy,…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habel, R.; Letardi, T.
1963-10-30
In some studies with scintillation chambers, the problem of discriminating between the events generated by one or more ionizing particles and a spontaneous shower between the gaps of the chamber is presented. One element of difference between the two events is the delay of the spurious scintillation with respect to that produced by passage of a particle. The use of a fast shutter whose open time is of the order of the delay would provide a possible method for the discrimination between true and spurious events. The experimental apparatus used and the types of measurements made to determine if suchmore » a shutter arrangement would be feasible are described. (J.S.R.)« less
Wu, Ping; Tu, Yunqiu; Qian, Yingdan; Zhang, Hui; Cai, Chenxin
2014-01-28
We report a new strategy for evaluating multiple miRNA expressions in cancer cells based on DNA strand-displacement-induced fluorescence enhancement. This assay has the ability to discriminate the target from even single-base mismatched sequences or other miRNAs.
Highly efficient red OLEDs using DCJTB as the dopant and delayed fluorescent exciplex as the host.
Zhao, Bo; Zhang, Tianyou; Chu, Bei; Li, Wenlian; Su, Zisheng; Wu, Hairuo; Yan, Xingwu; Jin, Fangming; Gao, Yuan; Liu, Chengyuan
2015-05-29
In this manuscript, we demonstrated a highly efficient DCJTB emission with delayed fluorescent exciplex TCTA:3P-T2T as the host. For the 1.0% DCJTB doped concentration, a maximum luminance, current efficiency, power efficiency and EQE of 22,767 cd m(-2), 22.7 cd A(-1), 21.5 lm W(-1) and 10.15% were achieved, respectively. The device performance is the best compared to either red OLEDs with traditional fluorescent emitter or traditional red phosphor of Ir(piq)3 doped into CBP host. The extraction of so high efficiency can be explained as the efficient triplet excitons up-conversion of TCTA:3P-T2T and the energy transfer from exciplex host singlet state to DCJTB singlet state.
Visuomotor sensitivity to visual information about surface orientation.
Knill, David C; Kersten, Daniel
2004-03-01
We measured human visuomotor sensitivity to visual information about three-dimensional surface orientation by analyzing movements made to place an object on a slanted surface. We applied linear discriminant analysis to the kinematics of subjects' movements to surfaces with differing slants (angle away form the fronto-parallel) to derive visuomotor d's for discriminating surfaces differing in slant by 5 degrees. Subjects' visuomotor sensitivity to information about surface orientation was very high, with discrimination "thresholds" ranging from 2 to 3 degrees. In a first experiment, we found that subjects performed only slightly better using binocular cues alone than monocular texture cues and that they showed only weak evidence for combining the cues when both were available, suggesting that monocular cues can be just as effective in guiding motor behavior in depth as binocular cues. In a second experiment, we measured subjects' perceptual discrimination and visuomotor thresholds in equivalent stimulus conditions to decompose visuomotor sensitivity into perceptual and motor components. Subjects' visuomotor thresholds were found to be slightly greater than their perceptual thresholds for a range of memory delays, from 1 to 3 s. The data were consistent with a model in which perceptual noise increases with increasing delay between stimulus presentation and movement initiation, but motor noise remains constant. This result suggests that visuomotor and perceptual systems rely on the same visual estimates of surface slant for memory delays ranging from 1 to 3 s.
Dos Santos, Paloma L; Ward, Jonathan S; Congrave, Daniel G; Batsanov, Andrei S; Eng, Julien; Stacey, Jessica E; Penfold, Thomas J; Monkman, Andrew P; Bryce, Martin R
2018-06-01
By inverting the common structural motif of thermally activated delayed fluorescence materials to a rigid donor core and multiple peripheral acceptors, reverse intersystem crossing (rISC) rates are demonstrated in an organic material that enables utilization of triplet excited states at faster rates than Ir-based phosphorescent materials. A combination of the inverted structure and multiple donor-acceptor interactions yields up to 30 vibronically coupled singlet and triplet states within 0.2 eV that are involved in rISC. This gives a significant enhancement to the rISC rate, leading to delayed fluorescence decay times as low as 103.9 ns. This new material also has an emission quantum yield ≈1 and a very small singlet-triplet gap. This work shows that it is possible to achieve both high photoluminescence quantum yield and fast rISC in the same molecule. Green organic light-emitting diode devices with external quantum efficiency >30% are demonstrated at 76 cd m -2 .
NASA Astrophysics Data System (ADS)
Crawford, I.; Ruske, S.; Topping, D. O.; Gallagher, M. W.
2015-11-01
In this paper we present improved methods for discriminating and quantifying primary biological aerosol particles (PBAPs) by applying hierarchical agglomerative cluster analysis to multi-parameter ultraviolet-light-induced fluorescence (UV-LIF) spectrometer data. The methods employed in this study can be applied to data sets in excess of 1 × 106 points on a desktop computer, allowing for each fluorescent particle in a data set to be explicitly clustered. This reduces the potential for misattribution found in subsampling and comparative attribution methods used in previous approaches, improving our capacity to discriminate and quantify PBAP meta-classes. We evaluate the performance of several hierarchical agglomerative cluster analysis linkages and data normalisation methods using laboratory samples of known particle types and an ambient data set. Fluorescent and non-fluorescent polystyrene latex spheres were sampled with a Wideband Integrated Bioaerosol Spectrometer (WIBS-4) where the optical size, asymmetry factor and fluorescent measurements were used as inputs to the analysis package. It was found that the Ward linkage with z-score or range normalisation performed best, correctly attributing 98 and 98.1 % of the data points respectively. The best-performing methods were applied to the BEACHON-RoMBAS (Bio-hydro-atmosphere interactions of Energy, Aerosols, Carbon, H2O, Organics and Nitrogen-Rocky Mountain Biogenic Aerosol Study) ambient data set, where it was found that the z-score and range normalisation methods yield similar results, with each method producing clusters representative of fungal spores and bacterial aerosol, consistent with previous results. The z-score result was compared to clusters generated with previous approaches (WIBS AnalysiS Program, WASP) where we observe that the subsampling and comparative attribution method employed by WASP results in the overestimation of the fungal spore concentration by a factor of 1.5 and the underestimation of bacterial aerosol concentration by a factor of 5. We suggest that this likely due to errors arising from misattribution due to poor centroid definition and failure to assign particles to a cluster as a result of the subsampling and comparative attribution method employed by WASP. The methods used here allow for the entire fluorescent population of particles to be analysed, yielding an explicit cluster attribution for each particle and improving cluster centroid definition and our capacity to discriminate and quantify PBAP meta-classes compared to previous approaches.
UV-Fluorescent Sensing for Primary Selection of Metal-rich Seafloor Massive Sulfide Ore
NASA Astrophysics Data System (ADS)
Yamazaki, T.; Nakatani, T.; Nakatani, N.; Arai, R.
2012-12-01
Seafloor massive sulfides (SMS) in the western Pacific have received much attention as resources for Au, Ag, Cu, Zn, and Pb. Because of the higher metal contents, the venture commercial mining project may start in 2013 in the East Manus Basin, Papua New Guinea. One of important problems to be solved is reducing the waste rock disposal costs for the economy. The best location for the reducing is on seafloor just after the excavation of SMS ores. The authors select UV-fluorescent sensing for primary selection of the ores, because no additional environmental impact is created with the application of the method. First of all, the effectiveness of the UV-fluorescent sensing by a combination system with a UV-light and a camera (See attached figure) in deep water condition is clarified. Then many UV-fluorescent data of SMS ore, SMS accompanied rock, and seafloor rock samples are collected. In the analyses phase, the ore and rock samples are classified into some groups by applying the cluster analysis to the metal contents at first. Then, using the UV fluorescent color brightness and contrasts of the ore and rock samples, the discriminant analysis based on Mahalanobis distance is applied. The higher possibility to identify the SMS ores containing valuable metals from camera image is suggested from the analyses. When additional UV-fluorescent and chemical assay data are obtained, the renewal of discriminant analysis is necessary. Therefore, the results and conclusions described in this study are tentative ones.; UV-fluorescent sensing
Phillipson, Lyn; Magee, Christopher; Jones, Sandra; Reis, Samantha; Skladzien, Ellen
2015-01-01
To investigate associations between dementia-attitudes and help-seeking intentions. An online survey of 611 Australian adults (45-60 years) assessed dementia-related attitudes and help-seeking intentions in response to two scenarios of an experience of early dementia: for themselves (Scenario 1); and for a significant other (proxy help-seeking) (Scenario 2). Logistic regression models examined the relationship between four dementia-related attitudes (labelled Personal Avoidance, Fear of Labelling, Fear of Discrimination and Person Centredness) and help-seeking intentions. Most participants indicated they would seek help from a general practitioner (GP) for themselves (82.2%) or for a proxy (78.7%) in response to the scenarios. Whilst only 7.2% indicated they would seek help from no-one, 21.3% would delay seeking help. In response to Scenario 1, Personal Avoidance and Fear of Labelling were associated with intentions to delay help-seeking. Fear of both Labelling and Discrimination were associated with intentions to seek help from no-one. In response to Scenario 2, Personal Avoidance was associated with intentions to delay proxy help-seeking and a reduced likelihood of seeking help by phone or and with Fear of Discrimination, via a GP. Fear of Labelling was also associated with an intention to delay proxy help-seeking. Efforts to improve help-seeking for dementia should address attitudes relating to stigma including negative labelling and a desire for the avoidance of people with dementia. Fears relating to discrimination indicate a need to build public confidence regarding the capacity of the health and workforce sectors to support people with dementia ethically and appropriately.
Yoneyama, Takeshi; Watanabe, Tetsuyo; Kagawa, Hiroyuki; Hayashi, Yutaka; Nakada, Mitsutoshi
2017-03-01
In photodynamic diagnosis using 5-aminolevulinic acid (5-ALA), discrimination between the tumor and normal tissue is very important for a precise resection. However, it is difficult to distinguish between infiltrating tumor and normal regions in the boundary area. In this study, fluorescent intensity and bright spot analyses using a confocal microscope is proposed for the precise discrimination between infiltrating tumor and normal regions. From the 5-ALA-resected brain tumor tissue, the red fluorescent and marginal regions were sliced for observation under a confocal microscope. Hematoxylin and eosin (H&E) staining were performed on serial slices of the same tissue. According to the pathological inspection of the H&E slides, the tumor and infiltrating and normal regions on confocal microscopy images were investigated. From the fluorescent intensity of the image pixels, a histogram of pixel number with the same fluorescent intensity was obtained. The fluorescent bright spot sizes and total number were compared between the marginal and normal regions. The fluorescence intensity distribution and average intensity in the tumor were different from those in the normal region. The probability of a difference from the dark enhanced the difference between the tumor and the normal region. The bright spot size and number in the infiltrating tumor were different from those in the normal region. Fluorescence intensity analysis is useful to distinguish a tumor region, and a bright spot analysis is useful to distinguish between infiltrating tumor and normal regions. These methods will be important for the precise resection or photodynamic therapy of brain tumors. Copyright © 2016 Elsevier B.V. All rights reserved.
Fluorescence imaging in the upper gastrointestinal tract for the detection of dysplasic changes
NASA Astrophysics Data System (ADS)
Sukowski, Uwe; Ebert, Bernd; Ortner, Marianne; Mueller, Karsten; Voderholzer, W.; Weber-Eibel, J.; Dietel, M.; Lochs, Herbert; Rinneberg, Herbert H.
2001-10-01
During endoscopy of the esophagus fluorescence images were recorded at a delay of 20 ns after pulsed laser excitation simultaneously with conventional reflected white light images. To label malignant cells (dysplasia, tumor) 5-aminolaevulinic acid was applied prior to fluorescence guided bi-opsy. In this way pre-malignant and malignant lesions were detected not seen previously during routine endoscopy.
Spectral and time-resolved studies on ocular structures
NASA Astrophysics Data System (ADS)
Schweitzer, D.; Jentsch, S.; Schenke, S.; Hammer, M.; Biskup, C.; Gaillard, E.
2007-07-01
Measurements of endogeous fluorophores open the possibility for evaluation of metabolic state at the eye. For interpretation of 2-dimensional measurements of time-resolved auto fluorescence in 2 separate spectral ranges at the human eye, comparing measurements were performed on porcine eyes. Determining excitation and emission spectra, attention was drawn of proof of coenzymes NADH and FAD in isolated anatomical structures cornea, aqueous humor, lens, vitreous, neuronal retina, retinal pigment epithelium (RPE), choroid, and sclera. All these structures exhibit auto fluorescence, highest in lens. Excitation at 350 nm results in local fluorescence maxima at 460 nm, corresponding to NADH, in all structures. This short-wave excitation allows metabolic studies only at the anterior eye, because of the limited transmission of the ocular media. During excitation at 446 nm the existence of FAD is expressed by local fluorescence maxima at 530 nm. The composition fluorescence spectra allow no discrimination between single ocular structures. Approximating the dynamic fluorescence by a double exponential function, the shortest lifetimes were detected in RPE and neuronal retina. The histograms of mean lifetime t M cover each other on lens with cornea and also on sclera with choroid. Despite the lifetimes are close between RPE and neuronal retina, the relative contributions Q I are wide different. The gradient of trend lines in cluster diagrams of amplitudes α II vs. α I allows a discrimination of ocular structures.
Asari, Masaru; Okuda, Katsuhiro; Hoshina, Chisato; Omura, Tomohiro; Tasaki, Yoshikazu; Shiono, Hiroshi; Matsubara, Kazuo; Shimizu, Keiko
2016-02-01
The aim of this study was to develop a cost-effective genotyping method using high-quality DNA for human identification. A total of 21 short tandem repeats (STRs) and amelogenin were selected, and fluorescent fragments at 22 loci were simultaneously amplified in a single-tube reaction using locus-specific primers with 24-base universal tails and four fluorescent universal primers. Several nucleotide substitutions in universal tails and fluorescent universal primers enabled the detection of specific fluorescent fragments from the 22 loci. Multiplex polymerase chain reaction (PCR) produced intense FAM-, VIC-, NED-, and PET-labeled fragments ranging from 90 to 400 bp, and these fragments were discriminated using standard capillary electrophoretic analysis. The selected 22 loci were also analyzed using two commercial kits (the AmpFLSTR Identifiler Kit and the PowerPlex ESX 17 System), and results for two loci (D19S433 and D16S539) were discordant between these kits due to mutations at the primer binding sites. All genotypes from the 100 samples were determined using 2.5 ng of DNA by our method, and the expected alleles were completely recovered. Multiplex 22-locus genotyping using four fluorescent universal primers effectively reduces the costs to less than 20% of genotyping using commercial kits, and our method would be useful to detect silent alleles from commercial kit analysis. Copyright © 2015 Elsevier Inc. All rights reserved.
Spectral features of biogenic calcium carbonates and implications for astrobiology
NASA Astrophysics Data System (ADS)
Berg, B. L.; Ronholm, J.; Applin, D. M.; Mann, P.; Izawa, M.; Cloutis, E. A.; Whyte, L. G.
2014-09-01
The ability to discriminate biogenic from abiogenic calcium carbonate (CaCO3) would be useful in the search for extant or extinct life, since CaCO3 can be produced by both biotic and abiotic processes on Earth. Bioprecipitated CaCO3 material was produced during the growth of heterotrophic microbial isolates on medium enriched with calcium acetate or calcium citrate. These biologically produced CaCO3, along with natural and synthetic non-biologically produced CaCO3 samples, were analysed by reflectance spectroscopy (0.35-2.5 μm), Raman spectroscopy (532 and 785 nm), and laser-induced fluorescence spectroscopy (365 and 405 nm excitation). Optimal instruments for the discrimination of biogenic from abiogenic CaCO3 were determined to be reflectance spectroscopy, and laser-induced fluorescence spectroscopy. Multiple absorption features in the visible light region occurred in reflectance spectra for most biogenic CaCO3 samples, which are likely due to organic pigments. Multiple fluorescence peaks occurred in emission spectra (405 nm excitation) of biogenic CaCO3 samples, which also are best attributed to the presence of organic compounds; however, further analyses must be performed in order to better determine the cause of these features to establish criteria for confirming the origin of a given CaCO3 sample. Raman spectroscopy was not useful for discrimination since any potential Raman peaks in spectra of biogenic carbonates collected by both the 532 and 785 nm lasers were overwhelmed by fluorescence. However, this also suggests that biogenic carbonates may be identified by the presence of this organic-associated fluorescence. No reliable spectroscopic differences in terms of parameters such as positions or widths of carbonate-associated absorption bands were found between the biogenic and abiogenic carbonate samples. These results indicate that the presence or absence of organic matter intimately associated with carbonate minerals is the only potentially useful spectral discriminator for the techniques that were examined, and that multiple spectroscopic techniques are capable of detecting the presence of associated organic materials. However, the presence or absence of intimately associated organic matter is not, in itself, an indicator of biogenicity.
Multispectral autofluorescence diagnosis of non-melanoma cutaneous tumors
NASA Astrophysics Data System (ADS)
Borisova, Ekaterina; Dogandjiiska, Daniela; Bliznakova, Irina; Avramov, Latchezar; Pavlova, Elmira; Troyanova, Petranka
2009-07-01
Fluorescent analysis of basal cell carcinoma (BCC), squamous cell carcinoma (SCC), keratoacanthoma and benign cutaneous lesions is carried out under initial phase of clinical trial in the National Oncological Center - Sofia. Excitation sources with maximum of emission at 365, 380, 405, 450 and 630 nm are applied for better differentiation between nonmelanoma malignant cutaneous lesions fluorescence and spectral discrimination from the benign pathologies. Major spectral features are addressed and diagnostic discrimination algorithms based on lesions' emission properties are proposed. The diagnostic algorithms and evaluation procedures found will be applied for development of an optical biopsy clinical system for skin cancer detection in the frames of National Oncological Center and other university hospital dermatological departments in our country.
The Fraunhofer line discriminator: An airborne fluorometer
NASA Technical Reports Server (NTRS)
Stoertz, G. E.
1969-01-01
An experimental Fraunhofer Line Discriminator (FLD) can differentiate and measure solar-stimulated luminescence when viewed against a background of reflected light. Key elements are two extremely sensitive photomultipliers, two glass-spaced Fabry-Perot filters having a bandwidth less than 1 A, and an analog computer. As in conventional fluorometers, concentration of a fluorescent substance is measured by comparison with standards. Quantitative use is probably accurate only at low altitudes but detection of luminescent substances should be possible from any altitude. Applications of the present FLD include remote sensing of fluorescent dyes used in studies of current dynamics. The basic technique is applicable to detection of oil spills, monitoring of pollutants, and sensing over land areas.
Bates, Mary E; Simmons, James A
2010-08-01
Big brown bats emit FM biosonar sounds containing two principal harmonics (FM1 approximately 55-22 kHz;FM2 approximately 105-45 kHz). To examine the role of harmonics, they were selectively filtered from stimuli in electronic-echo delay discrimination experiments. Positive stimuli were delayed by 3.16 ms (55 cm simulated target range); negative stimuli were by delayed by 3.96 ms (68 cm). This large 800-micros delay difference (nearly 14 cm) was easily discriminated for echoes containing equal-strength FM1 and FM2. Performance gradually decreased as highpass filters removed progressively larger segments from FM1. For echoes with FM2 alone, performance collapsed to chance, but performance remained good for lowpass echoes containing FM1 alone. Attenuation of FM2 by 3 dB relative to FM1 also decreased performance, but shortening electronic delay of the attenuated FM2 by 48 micros counteracted amplitude-latency trading and restored performance. Bats require the auditory representations of FM1 and FM2 to be in temporal register for high delay acuity. Misalignment of neuronal responses degrades acuity, but outright removal of FM2, leaving only FM1, causes little loss of acuity. Functional asymmetry of harmonics reflects lowpass effects from beaming and atmospheric propagation, which leave FM1 intact. It may cooperate with latency shifts to aid in suppression of clutter.
Pradère, B; Poulon, F; Compérat, E; Lucas, I; Bazin, D; Doizi, S; Cussenot, O; Traxer, O; Abi Haidar, D
2018-05-28
In the framework of urologic oncology, mini-invasive procedures have increased in the last few decades particularly for urothelial carcinoma. One of the essential elements in the management of this disease is still the diagnosis, which strongly influences the choice of treatment. The histopathologic evaluation of the tumor grade is a keystone of diagnosis, and tumor characterization is not possible with just a macroscopic evaluation. Even today intraoperative evaluation remains difficult despite the emergence of new technologies which use exogenous fluorophore. This study assessed an optical multimodal technique based on endogenous fluorescence, combining qualitative and quantitative analysis, for the diagnostic of urothelial carcinoma. It was found that the combination of two photon fluorescence, second harmonic generation microscopy, spectral analysis and fluorescence lifetime imaging were all able to discriminate tumor from healthy tissue, and to determine the grade of tumors. Spectral analysis of fluorescence intensity and the redox ratio used as quantitative evaluations showed statistical differences between low grade and high grade tumors. These results showed that multimodal optical analysis is a promising technology for the development of an optical fiber setup designed for an intraoperative diagnosis of urothelial carcinoma in the area of endourology. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Towards sensitive, high-throughput, biomolecular assays based on fluorescence lifetime
NASA Astrophysics Data System (ADS)
Ioanna Skilitsi, Anastasia; Turko, Timothé; Cianfarani, Damien; Barre, Sophie; Uhring, Wilfried; Hassiepen, Ulrich; Léonard, Jérémie
2017-09-01
Time-resolved fluorescence detection for robust sensing of biomolecular interactions is developed by implementing time-correlated single photon counting in high-throughput conditions. Droplet microfluidics is used as a promising platform for the very fast handling of low-volume samples. We illustrate the potential of this very sensitive and cost-effective technology in the context of an enzymatic activity assay based on fluorescently-labeled biomolecules. Fluorescence lifetime detection by time-correlated single photon counting is shown to enable reliable discrimination between positive and negative control samples at a throughput as high as several hundred samples per second.
Intensity coding in electric hearing: effects of electrode configurations and stimulation waveforms.
Chua, Tiffany Elise H; Bachman, Mark; Zeng, Fan-Gang
2011-01-01
Current cochlear implants typically stimulate the auditory nerve with biphasic pulses and monopolar electrode configurations. Tripolar stimulation can increase spatial selectivity and potentially improve place pitch related perception but requires higher current levels to elicit the same loudness as monopolar stimulation. The present study combined delayed pseudomonophonasic pulses, which produce lower thresholds, with tripolar stimulation in an attempt to solve the power-performance tradeoff problem. The present study systematically measured thresholds, dynamic range, loudness growth, and intensity discrimination using either biphasic or delayed pseudomonophonasic pulses under both monopolar and tripolar stimulation. Participants were five Clarion cochlear implant users. For each subject, data from apical, middle, and basal electrode positions were collected when possible. Compared with biphasic pulses, delayed pseudomonophonasic pulses increased the dynamic range by lowering thresholds while maintaining comparable maximum allowable levels under both electrode configurations. However, delayed pseudomonophonasic pulses did not change the shape of loudness growth function and actually increased intensity discrimination limens, especially at lower current levels. The present results indicate that delayed pseudomonophonasic pulses coupled with tripolar stimulation cannot provide significant power savings nor can it increase the functional dynamic range. Whether this combined stimulation could improve functional spectral resolution remains to be seen.
Diagnosis of meningioma by time-resolved fluorescence spectroscopy.
Butte, Pramod V; Pikul, Brian K; Hever, Aviv; Yong, William H; Black, Keith L; Marcu, Laura
2005-01-01
We investigate the use of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) as an adjunctive tool for the intraoperative rapid evaluation of tumor specimens and delineation of tumor from surrounding normal tissue. Tissue autofluorescence is induced with a pulsed nitrogen laser (337 nm, 1.2 ns) and the intensity decay profiles are recorded in the 370 to 500 nm spectral range with a fast digitizer (0.2 ns resolution). Experiments are conducted on excised specimens (meningioma, dura mater, cerebral cortex) from 26 patients (97 sites). Spectral intensities and time-dependent parameters derived from the time-resolved spectra of each site are used for tissue characterization. A linear discriminant analysis algorithm is used for tissue classification. Our results reveal that meningioma is characterized by unique fluorescence characteristics that enable discrimination of tumor from normal tissue with high sensitivity (>89%) and specificity (100%). The accuracy of classification is found to increase (92.8% cases in the training set and 91.8% in the cross-validated set correctly classified) when parameters from both the spectral and the time domain are used for discrimination. Our findings establish the feasibility of using TR-LIFS as a tool for the identification of meningiomas and enables further development of real-time diagnostic tools for analyzing surgical tissue specimens of meningioma or other brain tumors.
Diagnosis of meningioma by time-resolved fluorescence spectroscopy
Butte, Pramod V.; Pikul, Brian K.; Hever, Aviv; Yong, William H.; Black, Keith L.; Marcu, Laura
2010-01-01
We investigate the use of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) as an adjunctive tool for the intraoperative rapid evaluation of tumor specimens and delineation of tumor from surrounding normal tissue. Tissue autofluorescence is induced with a pulsed nitrogen laser (337 nm, 1.2 ns) and the intensity decay profiles are recorded in the 370 to 500 nm spectral range with a fast digitizer (0.2 ns resolution). Experiments are conducted on excised specimens (meningioma, dura mater, cerebral cortex) from 26 patients (97 sites). Spectral intensities and time-dependent parameters derived from the time-resolved spectra of each site are used for tissue characterization. A linear discriminant analysis algorithm is used for tissue classification. Our results reveal that meningioma is characterized by unique fluorescence characteristics that enable discrimination of tumor from normal tissue with high sensitivity (>89%) and specificity (100%). The accuracy of classification is found to increase (92.8% cases in the training set and 91.8% in the cross-validated set correctly classified) when parameters from both the spectral and the time domain are used for discrimination. Our findings establish the feasibility of using TR-LIFS as a tool for the identification of meningiomas and enables further development of real-time diagnostic tools for analyzing surgical tissue specimens of meningioma or other brain tumors. PMID:16409091
Lebaron, P; Servais, P; Agogué, H; Courties, C; Joux, F
2001-04-01
The nucleic acid contents of individual bacterial cells as determined with three different nucleic acid-specific fluorescent dyes (SYBR I, SYBR II, and SYTO 13) and flow cytometry were compared for different seawater samples. Similar fluorescence patterns were observed, and bacteria with high apparent nucleic acid contents (HNA) could be discriminated from bacteria with low nucleic acid contents (LNA). The best discrimination between HNA and LNA cells was found when cells were stained with SYBR II. Bacteria in different water samples collected from seven freshwater, brackish water, and seawater ecosystems were prelabeled with tritiated leucine and then stained with SYBR II. After labeling and staining, HNA, LNA, and total cells were sorted by flow cytometry, and the specific activity of each cellular category was determined from leucine incorporation rates. The HNA cells were responsible for most of the total bacterial production, and the specific activities of cells in the HNA population varied between samples by a factor of seven. We suggest that nucleic acid content alone can be a better indicator of the fraction of growing cells than total counts and that this approach should be combined with other fluorescent physiological probes to improve detection of the most active cells in aquatic systems.
Lebaron, Philippe; Servais, Pierre; Agogué, Helene; Courties, Claude; Joux, Fabien
2001-01-01
The nucleic acid contents of individual bacterial cells as determined with three different nucleic acid-specific fluorescent dyes (SYBR I, SYBR II, and SYTO 13) and flow cytometry were compared for different seawater samples. Similar fluorescence patterns were observed, and bacteria with high apparent nucleic acid contents (HNA) could be discriminated from bacteria with low nucleic acid contents (LNA). The best discrimination between HNA and LNA cells was found when cells were stained with SYBR II. Bacteria in different water samples collected from seven freshwater, brackish water, and seawater ecosystems were prelabeled with tritiated leucine and then stained with SYBR II. After labeling and staining, HNA, LNA, and total cells were sorted by flow cytometry, and the specific activity of each cellular category was determined from leucine incorporation rates. The HNA cells were responsible for most of the total bacterial production, and the specific activities of cells in the HNA population varied between samples by a factor of seven. We suggest that nucleic acid content alone can be a better indicator of the fraction of growing cells than total counts and that this approach should be combined with other fluorescent physiological probes to improve detection of the most active cells in aquatic systems. PMID:11282632
Highly efficient red OLEDs using DCJTB as the dopant and delayed fluorescent exciplex as the host
Zhao, Bo; Zhang, Tianyou; Chu, Bei; Li, Wenlian; Su, Zisheng; Wu, Hairuo; Yan, Xingwu; Jin, Fangming; Gao, Yuan; Liu, Chengyuan
2015-01-01
In this manuscript, we demonstrated a highly efficient DCJTB emission with delayed fluorescent exciplex TCTA:3P-T2T as the host. For the 1.0% DCJTB doped concentration, a maximum luminance, current efficiency, power efficiency and EQE of 22,767 cd m−2, 22.7 cd A−1, 21.5 lm W−1 and 10.15% were achieved, respectively. The device performance is the best compared to either red OLEDs with traditional fluorescent emitter or traditional red phosphor of Ir(piq)3 doped into CBP host. The extraction of so high efficiency can be explained as the efficient triplet excitons up-conversion of TCTA:3P-T2T and the energy transfer from exciplex host singlet state to DCJTB singlet state. PMID:26023882
Saito, Yoshio; Kugenuma, Kenji; Tanaka, Makiko; Suzuki, Azusa; Saito, Isao
2012-06-01
We demonstrated an intriguing method to discriminate adenine by incident appearance of an intense new emission via exciplex formation in hybridization of target DNA with newly designed fluorescent 8-arylethynylated deoxyguanosine derivatives. We described the synthesis of such highly electron donating fluorescent guanosine derivatives and their incorporation into DNA oligomers which may be used for the structural study and the fluorometric analysis of nucleic acids. Copyright © 2012 Elsevier Ltd. All rights reserved.
Airborne fluorometer applicable to marine and estuarine studies
Stoertz, George E.; Hemphill, William R.; Markle, David A.
1969-01-01
An experimental Fraunhofer line discriminator detected solar-stimulated yellow fluorescence (5890 A) emitted by Rhodamine WT dye in aqueous solutions. Concentration of 1 part per billion was detected in tap water 1/2-meter deep. In extremely turbid San Francisco Bay, dye was monitored in concentrations of less than 5 parts per billion from helicopter and ship. Applications include studies of current dynamics and dispersion. Potential applications of the technique could include sensing oil spills, fish oils, lignin sulfonates, other fluorescent pollutants, and chlorophyll fluorescence.
Catheter-based time-gated near-infrared fluorescence/OCT imaging system
NASA Astrophysics Data System (ADS)
Lu, Yuankang; Abran, Maxime; Cloutier, Guy; Lesage, Frédéric
2018-02-01
We developed a new dual-modality intravascular imaging system based on fast time-gated fluorescence intensity imaging and spectral domain optical coherence tomography (SD-OCT) for the purpose of interventional detection of atherosclerosis. A pulsed supercontinuum laser was used for fluorescence and OCT imaging. A double-clad fiber (DCF)- based side-firing catheter was designed and fabricated to have a 23 μm spot size at a 2.2 mm working distance for OCT imaging. Its single-mode core is used for OCT, while its inner cladding transports fluorescence excitation light and collects fluorescent photons. The combination of OCT and fluorescence imaging was achieved by using a DCF coupler. For fluorescence detection, we used a time-gated technique with a novel single-photon avalanche diode (SPAD) working in an ultra-fast gating mode. A custom-made delay chip was integrated in the system to adjust the delay between the excitation laser pulse and the SPAD gate-ON window. This technique allowed to detect fluorescent photons of interest while rejecting most of the background photons, thus leading to a significantly improved signal to noise ratio (SNR). Experiments were carried out in turbid media mimicking tissue with an indocyanine green (ICG) inclusion (1 mM and 100 μM) to compare the time-gated technique and the conventional continuous detection technique. The gating technique increased twofold depth sensitivity, and tenfold SNR at large distances. The dual-modality imaging capacity of our system was also validated with a silicone-based tissue-mimicking phantom.
Hutsell, Blake A; Banks, Matthew L
2015-08-15
Working memory is a domain of 'executive function.' Delayed nonmatching-to-sample (DNMTS) procedures are commonly used to examine working memory in both human laboratory and preclinical studies. The aim was to develop an automated DNMTS procedure maintained by food pellets in rhesus monkeys using a touch-sensitive screen attached to the housing chamber. Specifically, the DNMTS procedure was a 2-stimulus, 2-choice recognition memory task employing unidimensional discriminative stimuli and randomized delay interval presentations. DNMTS maintained a delay-dependent decrease in discriminability that was independent of the retention interval distribution. Eliminating reinforcer availability during a single delay session or providing food pellets before the session did not systematically alter accuracy, but did reduce total choices. Increasing the intertrial interval enhanced accuracy at short delays. Acute Δ(9)-THC pretreatment produced delay interval-dependent changes in the forgetting function at doses that did not alter total choices. Acute methylphenidate pretreatment only decreased total choices. All monkeys were trained to perform NMTS at the 1s training delay within 60 days of initiating operant touch training. Furthermore, forgetting functions were reliably delay interval-dependent and stable over the experimental period (∼6 months). Consistent with previous studies, increasing the intertrial interval improved DNMTS performance, whereas Δ(9)-THC disrupted DNMTS performance independent of changes in total choices. Overall, the touchscreen-based DNMTS procedure described provides an efficient method for training and testing experimental manipulations on working memory in unrestrained rhesus monkeys. Copyright © 2015 Elsevier B.V. All rights reserved.
Pigeons' Discrimination of Michotte's Launching Effect
ERIC Educational Resources Information Center
Young, Michael E.; Beckmann, Joshua S.; Wasserman, Edward A.
2006-01-01
We trained four pigeons to discriminate a Michotte launching animation from three other animations using a go/no-go task. The pigeons received food for pecking at one of the animations, but not for pecking at the others. The four animations featured two types of interactions among objects: causal (direct launching) and noncausal (delayed, distal,…
ERIC Educational Resources Information Center
Turchi, Janita; Buffalari, Deanne; Mishkin, Mortimer
2008-01-01
Monkeys trained in either one-trial recognition at 8- to 10-min delays or multi-trial discrimination habits with 24-h intertrial intervals received systemic cholinergic and dopaminergic antagonists, scopolamine and haloperidol, respectively, in separate sessions. Recognition memory was impaired markedly by scopolamine but not at all by…
Nam, Hyeong Soo; Kang, Woo Jae; Lee, Min Woo; Song, Joon Woo; Kim, Jin Won; Oh, Wang-Yuhl; Yoo, Hongki
2018-01-01
The pathophysiological progression of chronic diseases, including atherosclerosis and cancer, is closely related to compositional changes in biological tissues containing endogenous fluorophores such as collagen, elastin, and NADH, which exhibit strong autofluorescence under ultraviolet excitation. Fluorescence lifetime imaging (FLIm) provides robust detection of the compositional changes by measuring fluorescence lifetime, which is an inherent property of a fluorophore. In this paper, we present a dual-modality system combining a multispectral analog-mean-delay (AMD) FLIm and a high-speed swept-source optical coherence tomography (OCT) to simultaneously visualize the cross-sectional morphology and biochemical compositional information of a biological tissue. Experiments using standard fluorescent solutions showed that the fluorescence lifetime could be measured with a precision of less than 40 psec using the multispectral AMD-FLIm without averaging. In addition, we performed ex vivo imaging on rabbit iliac normal-looking and atherosclerotic specimens to demonstrate the feasibility of the combined FLIm-OCT system for atherosclerosis imaging. We expect that the combined FLIm-OCT will be a promising next-generation imaging technique for diagnosing atherosclerosis and cancer due to the advantages of the proposed label-free high-precision multispectral lifetime measurement. PMID:29675330
NASA Astrophysics Data System (ADS)
Arnold, Thomas; De Biasio, Martin; Leitner, Raimund
2015-06-01
Two problems are addressed in this paper (i) the fluorescent marker-based and the (ii) marker-free discrimination between healthy and cancerous human tissues. For both applications the performance of hyper-spectral methods are quantified. Fluorescent marker-based tissue classification uses a number of fluorescent markers to dye specific parts of a human cell. The challenge is that the emission spectra of the fluorescent dyes overlap considerably. They are, furthermore disturbed by the inherent auto-fluorescence of human tissue. This results in ambiguities and decreased image contrast causing difficulties for the treatment decision. The higher spectral resolution introduced by tunable-filter-based spectral imaging in combination with spectral unmixing techniques results in an improvement of the image contrast and therefore more reliable information for the physician to choose the treatment decision. Marker-free tissue classification is based solely on the subtle spectral features of human tissue without the use of artificial markers. The challenge in this case is that the spectral differences between healthy and cancerous tissues are subtle and embedded in intra- and inter-patient variations of these features. The contributions of this paper are (i) the evaluation of hyper-spectral imaging in combination with spectral unmixing techniques for fluorescence marker-based tissue classification, (ii) the evaluation of spectral imaging for marker-free intra surgery tissue classification. Within this paper, we consider real hyper-spectral fluorescence and endoscopy data sets to emphasize the practical capability of the proposed methods. It is shown that the combination of spectral imaging with multivariate statistical methods can improve the sensitivity and specificity of the detection and the staging of cancerous tissues compared to standard procedures.
Wu, Zhaofeng; Duan, Haiming; Li, Zhijun; Guo, Jixi; Zhong, Furu; Cao, Yali; Jia, Dianzeng
2017-11-20
The multichannel fluorescent sensor array based on nanofibrous membranes loaded with ZnS quantum dots (QDs) was created and demonstrated for the discriminative detection of explosives. The synergistic effect of the high surface-to-volume ratio of QDs, the good permeability of nanofibrous membranes and the differential response introduced by surface ligands was played by constructing the sensing array using nanofibrous membranes loaded with ZnS QDs featuring several surface ligands. Interestingly, although the fluorescence quenching of the nanofibrous membranes is not linearly related to the exposure time, the fingerprint of each explosive at different times is very similar in shape, and the fingerprints of the three explosives show different shapes. Three saturated vapors of nitroaromatic explosives could be reliably detected and discriminated by the array at room temperature. This work is the first step toward devising a monitoring system for explosives in the field of public security and defense. It could, for example, be coupled with the technology of image recognition and large data analysis for a rapid diagnostic test of explosives. This work further highlights the power of differential, multichannel arrays for the rapid and discriminative detection of a wide range of chemicals.
Wu, Zhaofeng; Duan, Haiming; Li, Zhijun; Guo, Jixi; Zhong, Furu; Cao, Yali; Jia, Dianzeng
2017-01-01
The multichannel fluorescent sensor array based on nanofibrous membranes loaded with ZnS quantum dots (QDs) was created and demonstrated for the discriminative detection of explosives. The synergistic effect of the high surface-to-volume ratio of QDs, the good permeability of nanofibrous membranes and the differential response introduced by surface ligands was played by constructing the sensing array using nanofibrous membranes loaded with ZnS QDs featuring several surface ligands. Interestingly, although the fluorescence quenching of the nanofibrous membranes is not linearly related to the exposure time, the fingerprint of each explosive at different times is very similar in shape, and the fingerprints of the three explosives show different shapes. Three saturated vapors of nitroaromatic explosives could be reliably detected and discriminated by the array at room temperature. This work is the first step toward devising a monitoring system for explosives in the field of public security and defense. It could, for example, be coupled with the technology of image recognition and large data analysis for a rapid diagnostic test of explosives. This work further highlights the power of differential, multichannel arrays for the rapid and discriminative detection of a wide range of chemicals. PMID:29156627
Specific Silencing of L392V PSEN1 Mutant Allele by RNA Interference
Sierant, Malgorzata; Paduszynska, Alina; Kazmierczak-Baranska, Julia; Nacmias, Benedetta; Sorbi, Sandro; Bagnoli, Silvia; Sochacka, Elzbieta; Nawrot, Barbara
2011-01-01
RNA interference (RNAi) technology provides a powerful molecular tool to reduce an expression of selected genes in eukaryotic cells. Short interfering RNAs (siRNAs) are the effector molecules that trigger RNAi. Here, we describe siRNAs that discriminate between the wild type and mutant (1174 C→G) alleles of human Presenilin1 gene (PSEN1). This mutation, resulting in L392V PSEN1 variant, contributes to early onset familial Alzheimer's disease. Using the dual fluorescence assay, flow cytometry and fluorescent microscopy we identified positions 8th–11th, within the central part of the antisense strand, as the most sensitive to mismatches. 2-Thiouridine chemical modification introduced at the 3′-end of the antisense strand improved the allele discrimination, but wobble base pairing adjacent to the mutation site abolished the siRNA activity. Our data indicate that siRNAs can be designed to discriminate between the wild type and mutant alleles of genes that differ by just a single nucleotide. PMID:21559198
Quantum Dot and Polymer Composite Cross-Reactive Array for Chemical Vapor Detection.
Bright, Collin J; Nallon, Eric C; Polcha, Michael P; Schnee, Vincent P
2015-12-15
A cross-reactive chemical sensing array was made from CdSe Quantum Dots (QDs) and five different organic polymers by inkjet printing to create segmented fluorescent composite regions on quartz substrates. The sensor array was challenged with exposures from two sets of analytes, including one set of 14 different functionalized benzenes and one set of 14 compounds related to security concerns, including the explosives trinitrotoluene (TNT) and ammonium nitrate. The array was broadly responsive to analytes with different chemical functionalities due to the multiple sensing mechanisms that altered the QDs' fluorescence. The sensor array displayed excellent discrimination between members within both sets. Classification accuracy of more than 93% was achieved, including the complete discrimination of very similar dinitrobenzene isomers and three halogenated, substituted benzene compounds. The simple fabrication, broad responsivity, and high discrimination capacity of this type of cross-reactive array are ideal qualities for the development of sensors with excellent sensitivity to chemical and explosive threats while maintaining low false alarm rates.
Johnson, Jeffrey S; Spencer, John P
2016-05-01
Studies examining the relationship between spatial attention and spatial working memory (SWM) have shown that discrimination responses are faster for targets appearing at locations that are being maintained in SWM, and that location memory is impaired when attention is withdrawn during the delay. These observations support the proposal that sustained attention is required for successful retention in SWM: If attention is withdrawn, memory representations are likely to fail, increasing errors. In the present study, this proposal was reexamined in light of a neural-process model of SWM. On the basis of the model's functioning, we propose an alternative explanation for the observed decline in SWM performance when a secondary task is performed during retention: SWM representations drift systematically toward the location of targets appearing during the delay. To test this explanation, participants completed a color discrimination task during the delay interval of a spatial-recall task. In the critical shifting-attention condition, the color stimulus could appear either toward or away from the midline reference axis, relative to the memorized location. We hypothesized that if shifting attention during the delay leads to the failure of SWM representations, there should be an increase in the variance of recall errors, but no change in directional errors, regardless of the direction of the shift. Conversely, if shifting attention induces drift of SWM representations-as predicted by the model-systematic changes in the patterns of spatial-recall errors should occur that would depend on the direction of the shift. The results were consistent with the latter possibility-recall errors were biased toward the locations of discrimination targets appearing during the delay.
Testing a Dynamic Field Account of Interactions between Spatial Attention and Spatial Working Memory
Johnson, Jeffrey S.; Spencer, John P.
2016-01-01
Studies examining the relationship between spatial attention and spatial working memory (SWM) have shown that discrimination responses are faster for targets appearing at locations that are being maintained in SWM, and that location memory is impaired when attention is withdrawn during the delay. These observations support the proposal that sustained attention is required for successful retention in SWM: if attention is withdrawn, memory representations are likely to fail, increasing errors. In the present study, this proposal is reexamined in light of a neural process model of SWM. On the basis of the model's functioning, we propose an alternative explanation for the observed decline in SWM performance when a secondary task is performed during retention: SWM representations drift systematically toward the location of targets appearing during the delay. To test this explanation, participants completed a color-discrimination task during the delay interval of a spatial recall task. In the critical shifting attention condition, the color stimulus could appear either toward or away from the memorized location relative to a midline reference axis. We hypothesized that if shifting attention during the delay leads to the failure of SWM representations, there should be an increase in the variance of recall errors but no change in directional error, regardless of the direction of the shift. Conversely, if shifting attention induces drift of SWM representations—as predicted by the model—there should be systematic changes in the pattern of spatial recall errors depending on the direction of the shift. Results were consistent with the latter possibility—recall errors were biased toward the location of discrimination targets appearing during the delay. PMID:26810574
ERIC Educational Resources Information Center
Mullen, Stuart; Dixon, Mark R.; Belisle, Jordan; Stanley, Caleb
2017-01-01
The current study sought to evaluate the efficacy of a stimulus equivalence training procedure in establishing auditory-tactile-visual stimulus classes with 2 children with autism and developmental delays. Participants were exposed to vocal-tactile (A-B) and tactile-picture (B-C) conditional discrimination training and were tested for the…
Highly efficient phosphorescent, TADF, and fluorescent OLEDs (Conference Presentation)
NASA Astrophysics Data System (ADS)
Kim, Jang-Joo; Kim, Kwon-Hyeon; Moon, Chang-Ki; Shin, Hyun
2016-09-01
High efficiency OLEDs based on phosphorescent, thermally activated delayed fluorescent (TADF) and fluorescent emitters will be presented. We will show that EQEs over 60% is achievable if OLEDs are fabricated using organic semiconductors with the refractive indices of 1.5 and fully horizontal emitting dipoles without any extra light extracting structure. We will also show that reverse intersystem crossing RISC rate plays an important role to reduce the efficiency roll-off in efficient TADF and fluorescent OLEDs and a couple to methods will be presented to increase the RISC rate in the devices.
NASA Astrophysics Data System (ADS)
Eshelman, E.; Daly, M. G.; Slater, G.; Cloutis, E.
2018-02-01
Many aromatic organic molecules exhibit strong and characteristic fluorescence when excited with ultraviolet radiation. As laser excitation in the ultraviolet generates both fluorescence and resonantly enhanced Raman scattering of aromatic vibrational modes, combined Raman and fluorescence instruments have been proposed to search for organic compounds on Mars. In this work the time-resolved fluorescence of a suite of 24 compounds composed of 2-5 ringed alternant, non-alternant, and heterocyclic PAHs was measured. Fluorescence instrumentation with similar specifications to a putative flight instrument was capable of observing the fluorescence decay of these compounds with a sub-ns resolution. Incorporating time-resolved capabilities was also found to increase the ability to discriminate between individual PAHs. Incorporating time-resolved fluorescence capabilities into an ultraviolet gated Raman system intended for a rover or lander can increase the ability to detect and characterize PAHs on planetary surfaces.
Ns-scaled time-gated fluorescence lifetime imaging for forensic document examination
NASA Astrophysics Data System (ADS)
Zhong, Xin; Wang, Xinwei; Zhou, Yan
2018-01-01
A method of ns-scaled time-gated fluorescence lifetime imaging (TFLI) is proposed to distinguish different fluorescent substances in forensic document examination. Compared with Video Spectral Comparator (VSC) which can examine fluorescence intensity images only, TFLI can detect questioned documents like falsification or alteration. TFLI system can enhance weak signal by accumulation method. The two fluorescence intensity images of the interval delay time tg are acquired by ICCD and fitted into fluorescence lifetime image. The lifetimes of fluorescence substances are represented by different colors, which make it easy to detect the fluorescent substances and the sequence of handwritings. It proves that TFLI is a powerful tool for forensic document examination. Furthermore, the advantages of TFLI system are ns-scaled precision preservation and powerful capture capability.
Lighting up micromotors with quantum dots for smart chemical sensing.
Jurado-Sánchez, B; Escarpa, A; Wang, J
2015-09-25
A new "on-the-fly" chemical optical detection strategy based on the incorporation of fluorescence CdTe quantum dots (QDs) on the surface of self-propelled tubular micromotors is presented. The motion-accelerated binding of trace Hg to the QDs selectively quenches the fluorescence emission and leads to an effective discrimination between different mercury species and other co-existing ions.
A dual-selective fluorescent probe for GSH and Cys detection: Emission and pH dependent selectivity.
Tang, Yunqiang; Jin, Longyi; Yin, Bingzhu
2017-11-15
A novel fluorescent probe 1 based on acridine orange was developed for the selective detection and bioimaging of biothiols. The probe exhibits higher selectivity and turn-on fluorescence response to cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) than to other amino acids. Importantly, the probe responds to GSH and Cys/Hcy with distinct fluorescence emissions in PBS buffer at pH of 7.4. The Cys/Hcy-triggered tandem S N Ar-rearrangement reaction and GSH-induced S N Ar reaction with the probe led to the corresponding amino-acridinium and thio-acridinium dyes, respectively, which can discriminate GSH from Cys/Hcy through different emission channels. Interestingly, Cys finishes the tandem reaction with the probe and subsequently forms amino-acridinium and Hcy/GSH induces S N Ar reaction with the probe to form thio-acridiniums at weakly acidic conditions (pH 6.0), enabling Cys to be discriminated from Hcy/GSH at different emissions. Finally, we demonstrated that probe 1 can selectively probe GSH over Cys and Hcy or Cys over GSH and Hcy in HeLa cells through multicolor imaging. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Du Le, Vinh Nguyen; Provias, John; Murty, Naresh; Patterson, Michael S.; Nie, Zhaojun; Hayward, Joseph E.; Farrell, Thomas J.; McMillan, William; Zhang, Wenbin; Fang, Qiyin
2017-02-01
Glioma itself accounts for 80% of all malignant primary brain tumors, and glioblastoma multiforme (GBM) accounts for 55% of such tumors. Diffuse reflectance and fluorescence spectroscopy have the potential to discriminate healthy tissues from abnormal tissues and therefore are promising noninvasive methods for improving the accuracy of brain tissue resection. Optical properties were retrieved using an experimentally evaluated inverse solution. On average, the scattering coefficient is 2.4 times higher in GBM than in low grade glioma (LGG), and the absorption coefficient is 48% higher. In addition, the ratio of fluorescence to diffuse reflectance at the emission peak of 460 nm is 2.6 times higher for LGG while reflectance at 650 nm is 2.7 times higher for GBM. The results reported also show that the combination of diffuse reflectance and fluorescence spectroscopy could achieve sensitivity of 100% and specificity of 90% in discriminating GBM from LGG during ex vivo measurements of 22 sites from seven glioma specimens. Therefore, the current technique might be a promising tool for aiding neurosurgeons in determining the extent of surgical resection of glioma and, thus, improving intraoperative tumor identification for guiding surgical intervention.
Du Le, Vinh Nguyen; Provias, John; Murty, Naresh; Patterson, Michael S; Nie, Zhaojun; Hayward, Joseph E; Farrell, Thomas J; McMillan, William; Zhang, Wenbin; Fang, Qiyin
2017-02-01
Glioma itself accounts for 80% of all malignant primary brain tumors, and glioblastoma multiforme (GBM) accounts for 55% of such tumors. Diffuse reflectance and fluorescence spectroscopy have the potential to discriminate healthy tissues from abnormal tissues and therefore are promising noninvasive methods for improving the accuracy of brain tissue resection. Optical properties were retrieved using an experimentally evaluated inverse solution. On average, the scattering coefficient is 2.4 times higher in GBM than in low grade glioma (LGG), and the absorption coefficient is 48% higher. In addition, the ratio of fluorescence to diffuse reflectance at the emission peak of 460 nm is 2.6 times higher for LGG while reflectance at 650 nm is 2.7 times higher for GBM. The results reported also show that the combination of diffuse reflectance and fluorescence spectroscopy could achieve sensitivity of 100% and specificity of 90% in discriminating GBM from LGG during ex vivo measurements of 22 sites from seven glioma specimens. Therefore, the current technique might be a promising tool for aiding neurosurgeons in determining the extent of surgical resection of glioma and, thus, improving intraoperative tumor identification for guiding surgical intervention.
The delaying effect of stigma on mental health help-seeking in Sri Lanka.
Fernando, Sunera M; Deane, Frank P; McLeod, Hamish J
2017-03-01
Mental health stigma has been associated with delays in seeking treatment. To describe perceived stigma experienced by patients and carers in Sri Lanka and to determine the effects of stigma on help-seeking delay. Survey of outpatients and family carers (n = 118 dyads) attending two psychiatric hospitals in Sri Lanka, using the Disclosure and Discrimination subscales of the Stigma Scale. Stigma was positively related to help-seeking delay for carers but not patients. Public stigma experienced by carers accounted for 23% of the variance in help-seeking delay. Reducing stigma may reduce help-seeking delays during the course of treatment. © 2016 John Wiley & Sons Australia, Ltd.
Red fluorescence of dental plaque in children -A cross-sectional study.
Volgenant, Catherine M C; Zaura, Egija; Brandt, Bernd W; Buijs, Mark J; Tellez, Marisol; Malik, Gayatri; Ismail, Amid I; Ten Cate, Jacob M; van der Veen, Monique H
2017-03-01
The relation between the presence of red fluorescent plaque and the caries status in children was studied. In addition, the microbial composition of dental plaque from sites with red fluorescent plaque (RFP) and from sites with no red fluorescent plaque (NFP) was assessed. Fluorescence photographs were taken from fifty children (6-14 years old) with overnight plaque. Full-mouth caries scores (ICDAS II) were obtained. The composition of a saliva sample and two plaque samples (RFP and NFP) was assessed using 16S rDNA sequencing. At the site level, no clinically relevant correlations were found between the presence of RFP and the caries status. At the subject level, a weak correlation was found between RFP and the caries status when non-cavitated lesions were included (r s =0.37, p=0.007). The microbial composition of RFP differed significantly from NFP. RFP had more anaerobes and more Gram-negative bacterial taxa. The most discriminative operational taxonomic units (OTUs) for RFP were Corynebacterium, Leptotrichia, Porphyromonas and Selenomonas, while the most discriminative OTUs for NFP were Neisseria, Actinomyces, Streptococcus and Rothia. There were no clinical relevant correlations in this cross-sectional study between the presence of RFP and (early) caries lesions. There were differences in the composition of these phenotypically different plaque samples: RFP contained more Gram-negative, anaerobic taxa and was more diverse than NFP. The study outcomes provide more insight in the possibilities to use plaque fluorescence in oral health risk assessments. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kochmann, Sven; Baleizão, Carlos; Berberan-Santos, Mário N; Wolfbeis, Otto S
2013-02-05
We report on a new method for sensing trace oxygen in the gas phase. It is based on the extreme efficiency of the quenching of the thermally activated delayed fluorescence of isotopically enriched carbon-13 fullerene C(70) ((13)C(70)). This fullerene was dissolved in polymer matrixes of varying oxygen permeability, viz., polystyrene (PS), ethyl cellulose (EC) and an organically modified silica gel ("ormosil"; OS). The sensor films (5-10 μm thick), on photoexcitation at 470 nm, display a strong delayed photoluminescence with peaks between 670 and 700 nm. Its quenching by molecular oxygen was studied at 25 and 60 °C and at concentrations from zero up to 150 ppmv of oxygen in nitrogen. The rapid lifetime determination (RLD) method was applied to determine oxygen-dependent lifetimes and for fluorescence lifetime imaging of oxygen. The lower limits of detection (at 1% quenching) vary with the polymer used (EC ∼250 ppbv, OS ∼320 ppbv, PS ∼530 ppbv at 25 °C) and with temperature. The oxygen sensors reported here are the most sensitive ones described so far.
Johnstone, C.W.
1959-09-29
A pulse-height discriminator for generating an output pulse when the accepted input pulse is approximately at its maximum value is described. A gating tube and a negative bias generator responsive to the derivative of the input pulse and means for impressing the output of the bias generator to at least one control electrode of the gating tube are included.
Bates, Mary E.; Simmons, James A.
2010-01-01
Big brown bats emit FM biosonar sounds containing two principal harmonics (FM1∼55–22 kHz;FM2∼105–45 kHz). To examine the role of harmonics, they were selectively filtered from stimuli in electronic-echo delay discrimination experiments. Positive stimuli were delayed by 3.16 ms (55 cm simulated target range); negative stimuli were by delayed by 3.96 ms (68 cm). This large 800-μs delay difference (nearly 14 cm) was easily discriminated for echoes containing equal-strength FM1 and FM2. Performance gradually decreased as highpass filters removed progressively larger segments from FM1. For echoes with FM2 alone, performance collapsed to chance, but performance remained good for lowpass echoes containing FM1 alone. Attenuation of FM2 by 3 dB relative to FM1 also decreased performance, but shortening electronic delay of the attenuated FM2 by 48 μs counteracted amplitude-latency trading and restored performance. Bats require the auditory representations of FM1 and FM2 to be in temporal register for high delay acuity. Misalignment of neuronal responses degrades acuity, but outright removal of FM2, leaving only FM1, causes little loss of acuity. Functional asymmetry of harmonics reflects lowpass effects from beaming and atmospheric propagation, which leave FM1 intact. It may cooperate with latency shifts to aid in suppression of clutter. PMID:20707464
Enhanced equivalence class formation by the delay and relational functions of meaningful stimuli.
Arntzen, Erik; Nartey, Richard K; Fields, Lanny
2015-05-01
Undergraduates in six groups of 10 attempted to form three 3-node 5-member equivalence classes (A → B → C → D → E) under the simultaneous protocol. In five of six groups, all stimuli were abstract shapes; in the PIC group, C stimuli were pictures with the remainder being abstract shapes. Before class formation, participants in the Identity-S and Identity-D groups were given preliminary training to form identity conditional discriminations with the C stimuli using simultaneous and 6 s delayed matching-to-sample procedures, respectively. In the Arbitrary-S and Arbitrary-D groups, before class formation, arbitrary conditional discriminations were formed between C and X stimuli using simultaneous and 6 s delayed matching-to-sample procedures, respectively. With no preliminary training, classes in the PIC and ABS groups were formed by 80% and 0% of participants, respectively. After preliminary training, class formation (yield) increased with delay, regardless of relational type. For each of the two delays, yield was slightly greater after forming arbitrary- instead of identity-relations. Yield was greatest, however, when a class contained a meaningful stimulus (PIC). During failed class formation, probes produced experimenter-defined relations, participant-defined relations, and unsystematic responding; delay, but not the relation type in preliminary training influenced relational and indeterminate responding. These results suggest how meaningful stimuli enhance equivalence class formation. © Society for the Experimental Analysis of Behavior.
Steele, Catherine C.; Peterson, Jennifer R.; Marshall, Andrew T.; Stuebing, Sarah L.; Kirkpatrick, Kimberly
2017-01-01
The nucleus accumbens core (NAc) has long been recognized as an important contributor to the computation of reward value that is critical for impulsive choice behavior. Impulsive choice refers to choosing a smaller-sooner (SS) over a larger-later (LL) reward when the LL is more optimal in terms of the rate of reward delivery. Two experiments examined the role of the NAc in impulsive choice and its component processes of delay and magnitude processing. Experiment 1 delivered an impulsive choice task with manipulations of LL reward magnitude, followed by a reward magnitude discrimination task. Experiment 2 tested impulsive choice under manipulations of LL delay, followed by temporal bisection and progressive interval tasks. NAc lesions, in comparison to sham control lesions, produced suboptimal preferences that resulted in lower reward earning rates, and led to reduced sensitivity to magnitude and delay within the impulsive choice task. The secondary tasks revealed intact reward magnitude and delay discrimination abilities, but the lesion rats persisted in responding more as the progressive interval increased during the session. The results suggest that the NAc is most critical for demonstrating good sensitivity to magnitude and delay, and adjusting behavior accordingly. Ultimately, the NAc lesions induced suboptimal choice behavior rather than simply promoting impulsive choice, suggesting that an intact NAc is necessary for optimal decision making. PMID:29146281
Donor-σ-Acceptor Motifs: Thermally Activated Delayed Fluorescence Emitters with Dual Upconversion.
Geng, Yan; D'Aleo, Anthony; Inada, Ko; Cui, Lin-Song; Kim, Jong Uk; Nakanotani, Hajime; Adachi, Chihaya
2017-12-22
A family of organic emitters with a donor-σ-acceptor (D-σ-A) motif is presented. Owing to the weakly coupled D-σ-A intramolecular charge-transfer state, a transition from the localized excited triplet state ( 3 LE) and charge-transfer triplet state ( 3 CT) to the charge-transfer singlet state ( 1 CT) occurred with a small activation energy and high photoluminescence quantum efficiency. Two thermally activated delayed fluorescence (TADF) components were identified, one of which has a very short lifetime of 200-400 ns and the other a longer TADF lifetime of the order of microseconds. In particular, the two D-σ-A materials presented strong blue emission with TADF properties in toluene. These results will shed light on the molecular design of new TADF emitters with short delayed lifetimes. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fluorescence lifetime endoscopy using TCSPC for the measurement of FRET in live cells
Fruhwirth, Gilbert O.; Ameer-Beg, Simon; Cook, Richard; Watson, Timothy; Ng, Tony; Festy, Frederic
2010-01-01
Development of remote imaging for diagnostic purposes has progressed dramatically since endoscopy began in the 1960’s. The recent advent of a clinically licensed intensity-based fluorescence micro-endoscopic instrument has offered the prospect of real-time cellular resolution imaging. However, interrogating protein-protein interactions deep inside living tissue requires precise fluorescence lifetime measurements to derive the Förster resonance energy transfer between two tagged fluorescent markers. We developed a new instrument combining remote fiber endoscopic cellular-resolution imaging with TCSPC-FLIM technology to interrogate and discriminate mixed fluorochrome labeled beads and expressible GFP/TagRFP tags within live cells. Endoscopic-FLIM (e-FLIM) data was validated by comparison with data acquired via conventional FLIM and e-FLIM was found to be accurate for both bright bead and dim live cell samples. The fiber based micro-endoscope allowed remote imaging of 4 µm and 10 µm beads within a thick Matrigel matrix with confident fluorophore discrimination using lifetime information. More importantly, this new technique enabled us to reliably measure protein-protein interactions in live cells embedded in a 3D matrix, as demonstrated by the dimerization of the fluorescent protein-tagged membrane receptor CXCR4. This cell-based application successfully demonstrated the suitability and great potential of this new technique for in vivo pre-clinical biomedical and possibly human clinical applications. PMID:20588974
Fluorescence quencher improves SCANSYSTEM for rapid bacterial detection.
Schmidt, M; Hourfar, M K; Wahl, A; Nicol, S-B; Montag, T; Roth, W K; Seifried, E
2006-05-01
The optimized scansystem could detect contaminated platelet products within 24 h. However, the system's sensitivity was reduced by a high fluorescence background even in sterile samples, which led to the necessity of a well-trained staff for confirmation of microscope results. A new protocol of the optimized scansystem with the addition of a fluorescence quencher was evaluated. Pool platelet concentrates contaminated with five transfusion-relevant bacterial strains were tested in a blind study. In conjunction with new analysis software, the new quenching dye was able to reduce significantly unspecific background fluorescence. Sensitivity was best for Bacillus cereus and Escherichia coli (3 CFU/ml). The application of a fluorescence quencher enables automated discrimination of positive and negative test results in 60% of all analysed samples.
Laser-induced fluorescence imaging of bacteria
NASA Astrophysics Data System (ADS)
Hilton, Peter J.
1998-12-01
This paper outlines a method for optically detecting bacteria on various backgrounds, such as meat, by imaging their laser induced auto-fluorescence response. This method can potentially operate in real-time, which is many times faster than current bacterial detection methods, which require culturing of bacterial samples. This paper describes the imaging technique employed whereby a laser spot is scanned across an object while capturing, filtering, and digitizing the returned light. Preliminary results of the bacterial auto-fluorescence are reported and plans for future research are discussed. The results to date are encouraging with six of the eight bacterial strains investigated exhibiting auto-fluorescence when excited at 488 nm. Discrimination of these bacterial strains against red meat is shown and techniques for reducing background fluorescence discussed.
Strand, Edythe A.; Fourakis, Marios; Jakielski, Kathy J.; Hall, Sheryl D.; Karlsson, Heather B.; Mabie, Heather L.; McSweeny, Jane L.; Tilkens, Christie M.; Wilson, David L.
2017-01-01
Purpose The goal of this article (PM I) is to describe the rationale for and development of the Pause Marker (PM), a single-sign diagnostic marker proposed to discriminate early or persistent childhood apraxia of speech from speech delay. Method The authors describe and prioritize 7 criteria with which to evaluate the research and clinical utility of a diagnostic marker for childhood apraxia of speech, including evaluation of the present proposal. An overview is given of the Speech Disorders Classification System, including extensions completed in the same approximately 3-year period in which the PM was developed. Results The finalized Speech Disorders Classification System includes a nosology and cross-classification procedures for childhood and persistent speech disorders and motor speech disorders (Shriberg, Strand, & Mabie, 2017). A PM is developed that provides procedural and scoring information, and citations to papers and technical reports that include audio exemplars of the PM and reference data used to standardize PM scores are provided. Conclusions The PM described here is an acoustic-aided perceptual sign that quantifies one aspect of speech precision in the linguistic domain of phrasing. This diagnostic marker can be used to discriminate early or persistent childhood apraxia of speech from speech delay. PMID:28384779
Intensity coding in electric hearing: Effects of electrode configurations and stimulation waveforms
Chua, Tiffany Elise H.; Bachman, Mark; Zeng, Fan-Gang
2011-01-01
Objectives Current cochlear implants typically stimulate the auditory nerve with biphasic pulses and monopolar electrode configurations. Tripolar stimulation can increase spatial selectivity and potentially improve place pitch related perception, but requires higher current levels to elicit the same loudness as monopolar stimulation. The present study combined delayed pseudomonophonasic pulses, which produce lower thresholds, with tripolar stimulation in an attempt to solve the power-performance tradeoff problem. Design The present study systematically measured thresholds, dynamic range, loudness growth, and intensity discrimination using either biphasic or delayed pseudomonophonasic pulses under both monopolar and tripolar stimulation. Participants were 5 Clarion cochlear implant users. For each subject, data from apical, middle and basal electrode positions were collected when possible. Results Compared with biphasic pulses, delayed pseudomonophonasic pulses increased the dynamic range by lowering thresholds while maintaining comparable maximum allowable levels under both electrode configurations. However, delayed pseudomonophonasic pulses did not change the shape of loudness growth function and actually increased intensity discrimination limens, especially at lower current levels. Conclusions The present results indicate that delayed pseudomonophonasic pulses coupled with tripolar stimulation cannot provide significant power savings, nor can it increase the functional dynamic range. Whether this combined stimulation could improve functional spectral resolution remains to be seen. PMID:21610498
ERIC Educational Resources Information Center
Boets, Bart; Verhoeven, Judith; Wouters, Jan; Steyaert, Jean
2015-01-01
We investigated low-level auditory spectral and temporal processing in adolescents with autism spectrum disorder (ASD) and early language delay compared to matched typically developing controls. Auditory measures were designed to target right versus left auditory cortex processing (i.e. frequency discrimination and slow amplitude modulation (AM)…
Sensitized phosphorescence of benzil-doped ladder-type methyl-poly(para-phenylene)
NASA Astrophysics Data System (ADS)
Bagnich, S. A.; Bässler, H.; Neher, D.
2004-11-01
The delayed luminescence and phosphorescence of ladder-type methyl-poly(para-phenylene) (MeLPPP) doped with benzil at a concentration of 20% by weight has been measured. The introduction of benzil leads to a dramatic reduction of the polymer singlet emission. At the same time, a new band with maximum at 611 nm appears, corresponding to the phosphorescence of MeLPPP. The phosphorescence decay on the short time scale is close to an exponential law with a time decay of 15 ms. This indicates that benzil can efficiently sensitize the phosphorescence of the polymer. In addition, a broad and featureless emission is observed in the delayed luminescence spectra of benzil-doped MeLPPP, which is attributed to an exciplex formed between the polymer host and the dopant. We further observe that the delayed fluorescence is enhanced by the addition of benzil. It is concluded that the delayed fluorescence of benzil-doped MeLPPP is mainly due to the annihilation of triplet excitons on the polymer. Finally, efficient triplet-triplet energy transfer from the benzil-doped polymer to the red-emitting phosphorescent dye Pt(II)octaethylporphyrin is established.
Qi, Yanyu; Xu, Wenjun; Kang, Rui; Ding, Nannan; Wang, Yelei; He, Gang; Fang, Yu
2018-02-21
This work reports a conceptual sensor array for the highly discriminative analysis of 20 clinically and environmentally relevant volatile small organic molecules (VSOMs), including saturated alkanes and common solvents, in the air at room temperature. For the construction of the sensor array, a four coordinated, non-planar mono-boron complex and four relevant polymers are synthesized. Based on the polymers and the use of different substrates, 8 fluorescent films have been fabricated. Integration of the film-based sensors results in the sensor array, which demonstrates unprecedented discriminating capability toward the VSOMs. Moreover, for the signal molecule of lung cancer, n -pentane, the response time is less than 1 s, the experimental detection limit is lower than 3.7 ppm, and after repeating the tests over 50 times no observable degradation was observed. The superior sensing performance is partially ascribed to the tetrahedral structure of the boron centers in the polymers as it may produce molecular channels in the films, which are a necessity for fast and reversible sensing. In addition, the polarity of the micro-channels may endow the films with additional selectivity towards the analytes. The design as demonstrated provides an effective strategy to improve the sensing performance of fluorescent films to very challenging analytes, such as saturated alkanes.
Romano, Maria; Di Taranto, Maria Donata; Mirabelli, Peppino; D'Agostino, Maria Nicoletta; Iannuzzi, Arcangelo; Marotta, Gennaro; Gentile, Marco; Raia, Maddalena; Di Noto, Rosa; Del Vecchio, Luigi; Rubba, Paolo; Fortunato, Giuliana
2011-01-01
The main causes of familial hypercholesterolemia (FH) are mutations in LDL receptor (LDLR) gene. Functional studies are necessary to demonstrate the LDLR function impairment caused by mutations and would be useful as a diagnostic tool if they allow discrimination between FH patients and controls. In order to identify the best method to detect LDLR activity, we compared continuous Epstein-Barr virus (EBV)-transformed B-lymphocytes and mitogen stimulated T-lymphocytes. In addition, we characterized both novel and known mutations in the LDLR gene. T-lymphocytes and EBV-transformed B-lymphocytes were obtained from peripheral blood of 24 FH patients and 24 control subjects. Functional assays were performed by incubation with fluorescent LDL followed by flow cytometry analysis. Residual LDLR activity was calculated normalizing fluorescence for the mean fluorescence of controls. With stimulated T-lymphocytes we obtained a better discrimination capacity between controls and FH patients compared with EBV-transformed B-lymphocytes as demonstrated by receiver operating characteristic (ROC) curve analysis (the areas under the curve are 1.000 and 0.984 respectively; P < 0.0001 both). The characterization of LDLR activity through T-lymphocytes is more simple and faster than the use of EBV-transformed B-lymphocytes and allows a complete discrimination between controls and FH patients. Therefore the evaluation of residual LDLR activity could be helpful not only for mutation characterization but also for diagnostic purposes. PMID:21865347
Fluorescence of fungi in superficial and deep fungal infections
Elston, Dirk M
2001-01-01
Background Fluorescence of many fungi is noted when H&E stained sections are examined under a fluorescent microscope. In theory, this phenomenon could aid in the diagnosis of cutaneous and disseminated fungal infections without the delay associated with special stains. Seventy-six cases of superficial and deep fungal infections and 3 cases of protothecosis were studied to determine the clinical usefulness of this technique. Results In most cases, fluorescence was noted, but was not intense. Fluorescence of fungi did not correlate with the age of the specimen. In most cases, organisms in H&E stained sections were more easily identified with routine light microscopy than with fluorescent microscopy. Conclusion This report suggests that in H&E stained skin specimens, fluorescent microscopy is of little benefit in the identification of fungal organisms. PMID:11602016
An Experimental Investigation of Hypergolic Ignition Delay of Hydrogen Peroxide with Fuel Mixtures
NASA Technical Reports Server (NTRS)
Blevins, John A.; Gostowski, Rudy; Chianese, Silvio
2003-01-01
An experimental investigation of hypergolicity and ignition delay of fuel mixtures with hydrogen peroxide is presented. Example results of high speed photography and schleiren from drop tests are shown. Also, a discussion of the sensitivity to experimental parameters such as drop size and subsequent uncertainty considerations of ignition delay results is presented. It is shown that using the described setup on the mixtures presented, the precision uncertainty is on the order of 6% of average ignition delay and 5% of average decomposition delay. This represents sufficient repeatability for first order discrimination of ignition delay for propellant development and screening. Two mixtures, each using commonly available amines and transition metal compounds, are presented as examples that result in ignition delays on the order of 10 milliseconds.
Wright, Thomas M; King, Madeleine V; Davey, William G; Langley-Evans, Simon C; Voigt, Jörg-Peter W
2014-12-28
There is increasing evidence that hyperenergetic diets have an impact on memory in rodents. However, it is largely unknown how diets, such as a cafeteria diet (CD), that mimic a Western-type diet act on learning and memory, in particular when fed during early stages of development. Here, we fed lactating dams a CD and exposed both male and female offspring to a novel object discrimination (NOD) task, a two-trial test of recognition memory in which rats exposed to two identical objects during a training/familiarisation trial can discriminate a novel from a familiar object during the subsequent choice trial. The choice trial was performed following inter-trial interval (ITI) delays of up to 4 h. Maternal diet did not have an impact on exploration of the objects by either sex during the familiarisation trial. Control males discriminated the novel from the familiar object, indicating intact memory with an ITI of 1 h, but not 2 or 4 h. The CD delayed this natural forgetting in male rats such that discrimination was also evident after a 2 h ITI. In contrast, control females exhibited discrimination following both 1 and 2 h ITI, but the CD impaired performance. In summary, the present study shows that maternal exposure to the CD programmes NOD in the adult. In better-performing females, dietary programming interferes with NOD, whereas NOD was improved in males after lactational CD feeding.
NASA Astrophysics Data System (ADS)
Hartl, Brad A.; Ma, Htet S. W.; Sridharan, Shamira; Hansen, Katherine; Klich, Melanie; Perks, Julian; Kent, Michael; Kim, Kyoungmi; Fragoso, Ruben; Marcu, Laura
2017-02-01
Differentiating radiation-induced necrosis from recurrent tumor in the brain remains a significant challenge to the neurosurgeon. Clinical imaging modalities are not able to reliably discriminate the two tissue types, making biopsy location selection and surgical management difficult. Label-free fluorescence lifetime techniques have previously been shown to be able to delineate human brain tumor from healthy tissues. Thus, fluorescence lifetime techniques represent a potential means to discriminate the two tissues in real-time during surgery. This study aims to characterize the endogenous fluorescence lifetime signatures from radiation induced brain necrosis in a tumor-free rat model. Fischer rats received a single fraction of 60 Gy of radiation to the right hemisphere using a linear accelerator. Animals underwent a terminal live surgery after gross necrosis had developed, as verified with MRI. During surgery, healthy and necrotic brain tissue was measured with a fiber optic needle connected to a multispectral fluorescence lifetime system. Measurements of the necrotic tissue showed a 48% decrease in intensity and 20% increase in lifetimes relative to healthy tissue. Using a support vector machine classifier and leave-one-out validation technique, the necrotic tissue was correctly classified with 94% sensitivity and 97% specificity. Spectral contribution analysis also confirmed that the primary source of fluorescence contrast lies within the redox and bound-unbound population shifts of nicotinamide adenine dinucleotide. A clinical trial is presently underway to measure these tissue types in humans. These results show for the first time that radiation-induced necrotic tissue in the brain contains significantly different metabolic signatures that are detectable with label-free fluorescence lifetime techniques.
Valdés, Pablo A.; Leblond, Frederic; Kim, Anthony; Harris, Brent T.; Wilson, Brian C.; Fan, Xiaoyao; Tosteson, Tor D.; Hartov, Alex; Ji, Songbai; Erkmen, Kadir; Simmons, Nathan E.; Paulsen, Keith D.; Roberts, David W.
2011-01-01
Object Accurate discrimination between tumor and normal tissue is crucial for optimal tumor resection. Qualitative fluorescence of protoporphyrin IX (PpIX), synthesized endogenously following δ-aminolevulinic acid (ALA) administration, has been used for this purpose in high-grade glioma (HGG). The authors show that diagnostically significant but visually imperceptible concentrations of PpIX can be quantitatively measured in vivo and used to discriminate normal from neoplastic brain tissue across a range of tumor histologies. Methods The authors studied 14 patients with diagnoses of low-grade glioma (LGG), HGG, meningioma, and metastasis under an institutional review board–approved protocol for fluorescence-guided resection. The primary aim of the study was to compare the diagnostic capabilities of a highly sensitive, spectrally resolved quantitative fluorescence approach to conventional fluorescence imaging for detection of neoplastic tissue in vivo. Results A significant difference in the quantitative measurements of PpIX concentration occurred in all tumor groups compared with normal brain tissue. Receiver operating characteristic (ROC) curve analysis of PpIX concentration as a diagnostic variable for detection of neoplastic tissue yielded a classification efficiency of 87% (AUC = 0.95, specificity = 92%, sensitivity = 84%) compared with 66% (AUC = 0.73, specificity = 100%, sensitivity = 47%) for conventional fluorescence imaging (p < 0.0001). More than 81% (57 of 70) of the quantitative fluorescence measurements that were below the threshold of the surgeon's visual perception were classified correctly in an analysis of all tumors. Conclusions These findings are clinically profound because they demonstrate that ALA-induced PpIX is a targeting biomarker for a variety of intracranial tumors beyond HGGs. This study is the first to measure quantitative ALA-induced PpIX concentrations in vivo, and the results have broad implications for guidance during resection of intracranial tumors. PMID:21438658
Durán Merás, Isabel; Domínguez Manzano, Jaime; Airado Rodríguez, Diego; Muñoz de la Peña, Arsenio
2018-02-01
Within olive oils, extra virgin olive oil is the highest quality and, in consequence, the most expensive one. Because of that, it is common that some merchants attempt to take economic advantage by mixing it up with other less expensive oils, like olive oil or olive pomace oil. In consequence, the characterization and authentication of extra virgin olive oils is a subject of great interest, both for industry and consumers. This paper reports the potential of front-face total fluorescence spectroscopy combined with second-order chemometric methods for the detection of extra virgin olive oils adulteration with other olive oils. Excitation-emission matrices (EEMs) of extra virgin olive oils and extra virgin olive oils adulterated with olive oils or with olive pomace oils were recorded using front-face fluorescence spectroscopy. The full information content in these fluorescence images was analyzed with the aid of unsupervised parallel factor analysis (PARAFAC), PARAFAC supervised by linear discriminant analysis (LDA-PARAFAC), and discriminant unfolded partial least-squares (DA-UPLS). The discriminant ability of LDA-PARAFAC was studied through the tridimensional plots of the canonical vectors, defining a surface separating the established categories. For DA-UPLS, the discriminant ability was established through the bidimensional plots of predicted values of calibration and validation samples, in order to assign each sample to a given class. The models demonstrated the possibility of detecting adulterations of extra virgin olive oils with percentages of around 15% and 3% of olive and olive pomace oils, respectively. Also, UPLS regression was used to quantify the adulteration level of extra virgin olive oils with olive oils or with olive pomace oils. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Ruilong; Zhao, Jun; Han, Guangmei; Liu, Zhengjie; Liu, Cui; Zhang, Cheng; Liu, Bianhua; Jiang, Changlong; Liu, Renyong; Zhao, Tingting; Han, Ming-Yong; Zhang, Zhongping
2016-03-23
Fluorescent probes are powerful tools for the investigations of reactive oxygen species (ROS) in living organisms by visualization and imaging. However, the multiparallel assays of several ROS with multiple probes are often limited by the available number of spectrally nonoverlapping chromophores together with large invasive effects and discrepant biological locations. Meanwhile, the spontaneous ROS profilings in various living organs/tissues are also limited by the penetration capability of probes across different biological barriers and the stability in reactive in vivo environments. Here, we report a single fluorescent probe to achieve the effective discrimination and profiling of hydroxyl radicals (•OH) and hypochlorous acid (HClO) in living organisms. The probe is constructed by chemically grafting an additional five-membered heterocyclic ring and a lateral triethylene glycol chain to a fluorescein mother, which does not only turn off the fluorescence of fluorescein, but also create the dual reactive sites to ROS and the penetration capability in passing through various biological barriers. The reactions of probe with •OH and HClO simultaneously result in cyan and green emissions, respectively, providing the real-time discrimination and quantitative analysis of the two ROS in cellular mitochondria. Surprisingly, the accumulation of probes in the intestine and liver of a normal-state zebrafish and the transfer pathway from intestine-to-blood-to-organ/tissue-to-kidney-to-excretion clearly present the profiling of spontaneous •OH and HClO in these metabolic organs. In particular, the stress generation of •OH at the fresh wound of zebrafish is successfully visualized for the first time, in spite of its extremely short lifetime.
NASA Astrophysics Data System (ADS)
Hatakeyama, Takuji; Ikuta, Toshiaki; Shiren, Kazushi; Nakajima, Kiichi; Nomura, Shintaro; Ni, Jingping
2016-09-01
Organic light-emitting diodes (OLEDs) play an important role in the new generation of flat-panel displays. Conventional OLEDs employing fluorescent materials together with triplet-triplet annihilation suffer from a relatively low internal quantum efficiency (IQE) of 62.5%. On the other hand, the IQE of OLEDs employing phosphorescent or thermally activated delayed fluorescence (TADF) materials can reach 100%. However, these materials exhibit very broad peaks with a full-width at half-maximum (FWHM) of 70-100 nm and cannot satisfy the color-purity requirements for displays. Therefore, the latest commercial OLED displays employ blue fluorescent materials with a relatively low IQE, and efficient blue emitters with a small FWHM are highly needed. In our manuscript, we present organic molecules that exhibit ultrapure blue fluorescence based on TADF. These molecules consist of three benzene rings connected by one boron and two nitrogen atoms, which establish a rigid polycyclic framework and significant localization of the highest occupied and lowest unoccupied molecular orbitals by a multiple resonance effect. An OLED device based on the new emitter exhibits ultrapure blue emission at 467 nm with an FWHM of 28 nm, Commission Internationale de l'Eclairage (CIE) coordinates of (0.12, 0.13), and an IQE of 100%, which represent record-setting performance for blue OLED devices.
Estis, Julie M; Coblentz, Joana K; Moore, Robert E
2009-07-01
Trained singers (TS) generally demonstrate accurate pitch matching, but this ability varies within the general population. Pitch-matching accuracy, given increasing silence intervals of 5, 15, and 25 seconds between target tones and vocal matches, was investigated in TS and untrained individuals. A relationship between pitch discrimination and pitch matching was also examined. Thirty-two females (20-30 years) were grouped based on individual vocal training and performance in an immediate pitch-matching task. Participants matched target pitches following time delays, and completed a pitch discrimination task, which required the classification of two tones as same or different. TS and untrained accurate participants performed comparably on all pitch-matching tasks, while untrained inaccurate participants performed significantly less accurately than the other two groups. Performances declined across groups as intervals of silence increased, suggesting degradation of pitch matching as pitch memory was taxed. A significant relationship between pitch discrimination and pitch matching was revealed across participants.
Evidence for distinct human auditory cortex regions for sound location versus identity processing
Ahveninen, Jyrki; Huang, Samantha; Nummenmaa, Aapo; Belliveau, John W.; Hung, An-Yi; Jääskeläinen, Iiro P.; Rauschecker, Josef P.; Rossi, Stephanie; Tiitinen, Hannu; Raij, Tommi
2014-01-01
Neurophysiological animal models suggest that anterior auditory cortex (AC) areas process sound-identity information, whereas posterior ACs specialize in sound location processing. In humans, inconsistent neuroimaging results and insufficient causal evidence have challenged the existence of such parallel AC organization. Here we transiently inhibit bilateral anterior or posterior AC areas using MRI-guided paired-pulse transcranial magnetic stimulation (TMS) while subjects listen to Reference/Probe sound pairs and perform either sound location or identity discrimination tasks. The targeting of TMS pulses, delivered 55–145 ms after Probes, is confirmed with individual-level cortical electric-field estimates. Our data show that TMS to posterior AC regions delays reaction times (RT) significantly more during sound location than identity discrimination, whereas TMS to anterior AC regions delays RTs significantly more during sound identity than location discrimination. This double dissociation provides direct causal support for parallel processing of sound identity features in anterior AC and sound location in posterior AC. PMID:24121634
Discriminative detection and enumeration of microbial life in marine subsurface sediments.
Morono, Yuki; Terada, Takeshi; Masui, Noriaki; Inagaki, Fumio
2009-05-01
Detection and enumeration of microbial life in natural environments provide fundamental information about the extent of the biosphere on Earth. However, it has long been difficult to evaluate the abundance of microbial cells in sedimentary habitats because non-specific binding of fluorescent dye and/or auto-fluorescence from sediment particles strongly hampers the recognition of cell-derived signals. Here, we show a highly efficient and discriminative detection and enumeration technique for microbial cells in sediments using hydrofluoric acid (HF) treatment and automated fluorescent image analysis. Washing of sediment slurries with HF significantly reduced non-biological fluorescent signals such as amorphous silica and enhanced the efficiency of cell detachment from the particles. We found that cell-derived SYBR Green I signals can be distinguished from non-biological backgrounds by dividing green fluorescence (band-pass filter: 528/38 nm (center-wavelength/bandwidth)) by red (617/73 nm) per image. A newly developed automated microscope system could take a wide range of high-resolution image in a short time, and subsequently enumerate the accurate number of cell-derived signals by the calculation of green to red fluorescence signals per image. Using our technique, we evaluated the microbial population in deep marine sediments offshore Peru and Japan down to 365 m below the seafloor, which provided objective digital images as evidence for the quantification of the prevailing microbial life. Our method is hence useful to explore the extent of sub-seafloor life in the future scientific drilling, and moreover widely applicable in the study of microbial ecology.
Chen, Hongqi; Ren, Jicun
2012-04-21
A new method for quenching kinetic discrimination of Fe(2+) and Fe(3+), and sensitive detection of trace amount of Fe(2+) was developed by using synchronous fluorescence scan technique. The principle of this assay is based on the quenching kinetic discrimination of Fe(2+) and Fe(3+) in CePO(4):Tb(3+) nanocrytals-H(2)O(2) hybrid system and the Fenton reaction between Fe(2+) and H(2)O(2). Stable, water-soluble and well-dispersible CePO(4):Tb(3+) nanocrystals were synthesized in aqueous solutions, and characterized by transmission electron microscopy (TEM) and electron diffraction spectroscopy (EDS). We found that both Fe(2+) and Fe(3+) could quench the synchronous fluorescence of CePO(4):Tb(3+) nanocrytals-H(2)O(2) system, but their quenching kinetics velocities were quite different. In the presence of Fe(3+), the synchronous fluorescent intensity was unchanged after only one minute, but in the presence of Fe(2+), the synchronous fluorescent intensity decreased slowly until 28 min later. The Fenton reaction between Fe(2+) and H(2)O(2) resulted in hydroxyl radicals which effectively quenched the synchronous fluorescence of the CePO(4):Tb(3+) nanocrystals due to the oxidation of Ce(3+) into Ce(4+) by hydroxyl radicals. Under optimum conditions, the linear range for Fe(2+) is 3 nM-2 μM, and the limit of detection is 2.0 nM. The method was used to analyze water samples.
Spectral Changes of Erythrosin B Luminescence Upon Binding to Bovine Serum Albumin
NASA Astrophysics Data System (ADS)
Sablin, N. V.; Gerasimova, M. A.; Nemtseva, E. V.
2016-04-01
Changes in absorption, fluorescence, phosphorescence, and delayed fluorescence spectra of erythrosin B are studied in the presence of bovine serum albumin at room temperature. Spectral and chronoscopic characteristics of the observed photophysical processes are defined. The binding of erythrosin B with the protein followed by spectral changes is demonstrated. Absorption and fluorescence spectra of the dye in the bound state are described, the binding mechanism is analyzed. The binding parameters of the dye-protein complex are estimated.
Jo, J A; Fang, Q; Papaioannou, T; Qiao, J H; Fishbein, M C; Dorafshar, A; Reil, T; Baker, D; Freischlag, J; Marcu, L
2004-01-01
This study investigates the ability of new analytical methods of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data to characterize tissue in-vivo, such as the composition of atherosclerotic vulnerable plaques. A total of 73 TR-LIFS measurements were taken in-vivo from the aorta of 8 rabbits, and subsequently analyzed using the Laguerre deconvolution technique. The investigated spots were classified as normal aorta, thin or thick lesions, and lesions rich in either collagen or macrophages/foam-cells. Different linear and nonlinear classification algorithms (linear discriminant analysis, stepwise linear discriminant analysis, principal component analysis, and feedforward neural networks) were developed using spectral and TR features (ratios of intensity values and Laguerre expansion coefficients, respectively). Normal intima and thin lesions were discriminated from thick lesions (sensitivity >90%, specificity 100%) using only spectral features. However, both spectral and time-resolved features were necessary to discriminate thick lesions rich in collagen from thick lesions rich in foam cells (sensitivity >85%, specificity >93%), and thin lesions rich in foam cells from normal aorta and thin lesions rich in collagen (sensitivity >85%, specificity >94%). Based on these findings, we believe that TR-LIFS information derived from the Laguerre expansion coefficients can provide a valuable additional dimension for in-vivo tissue characterization.
Design strategies of fluorescent probes for selective detection among biothiols.
Niu, Li-Ya; Chen, Yu-Zhe; Zheng, Hai-Rong; Wu, Li-Zhu; Tung, Chen-Ho; Yang, Qing-Zheng
2015-10-07
Simple thiol derivatives, such as cysteine (Cys), homocysteine (Hcy), and glutathione (GSH), play key roles in biological processes, and the fluorescent probes to detect such thiols in vivo selectively with high sensitivity and fast response times are critical for understanding their numerous functions. However, the similar structures and reactivities of these thiols pose considerable challenges to the development of such probes. This review focuses on various strategies for the design of fluorescent probes for the selective detection of biothiols. We classify the fluorescent probes for discrimination among biothiols according to reaction types between the probes and thiols such as cyclization with aldehydes, conjugate addition-cyclization with acrylates, native chemical ligation, and aromatic substitution-rearrangement.
Synthesis of plastic scintillation microspheres: alpha/beta discrimination.
Santiago, L M; Bagán, H; Tarancón, A; Garcia, J F
2014-11-01
Plastic scintillation microspheres (PSm) have been developed as an alternative for liquid scintillation cocktails due to their ability to avoid the mixed waste, besides other strengths in which the possibility for alpha/beta discrimination is included. The aim of this work was to evaluate the capability of PSm containing two combinations of fluorescence solutes (PPO/POPOP and pT/Bis-MSB) and variable amounts of a second organic solvent (naphthalene) to enhance the alpha/beta discrimination. Two commercial detectors with different Pulse Shape Discrimination performances (Quantulus and Triathler) were used to evaluate the alpha/beta discrimination. An optimal discrimination of alpha/beta particles was reached, with very low misclassification values (2% for beta particles and 0.5% for alpha particles), when PSm containing PPO/POPOP and between 0.6 and 2.0 g of naphthalene were evaluated using Triathler and the appropriate programme for data processing. Copyright © 2014 Elsevier Ltd. All rights reserved.
Wu, Kailong; Wang, Zian; Zhan, Lisi; Zhong, Cheng; Gong, Shaolong; Xie, Guohua; Yang, Chuluo
2018-04-05
Two new blue emitters, i.e., bis-[2-(9,9-dimethyl-9,10-dihydroacridine)-phenyl]-sulfone ( o-ACSO2) and bis-[3-(9,9-dimethyl-9,10-dihydroacridine)-phenyl]-sulfone ( m-ACSO2), with reserved fine thermally activated delayed fluorescent (TADF) nature and simply tuned thermal and optoelectronic properties, were synthesized by isomer engineering. The meta-linking compound, i.e., m-ACSO2, obtains the highest photoluminescence quantum yield with a small singlet-triplet energy gap, a moderate delayed fluorescent lifetime, excellent solubility, and neat film homogeneity. Due to its unique aggregation-induced emission (AIE) character, neat film-based heterojunction-like organic light-emitting diodes (OLEDs) are achievable. By inserting an excitonic inert exciton-blocking layer, the PN heterojunction-like emission accompanied by intefacial exciplex was shifted to a homojunction-like channel mainly from the AIE emitter itself, providing a new tactic to generate efficient blue color from neat films. The solution-processed nondoped sky-blue OLED employing m-ACSO2 as emitter with homojunction-like emission achieved a maximum external quantum efficiency of 17.2%. The design strategies presented herein provide practical methods to construct efficient blue TADF dyes and realize high-performance blue TADF devices.
Myosin-X functions in polarized epithelial cells
Liu, Katy C.; Jacobs, Damon T.; Dunn, Brian D.; Fanning, Alan S.; Cheney, Richard E.
2012-01-01
Myosin-X (Myo10) is an unconventional myosin that localizes to the tips of filopodia and has critical functions in filopodia. Although Myo10 has been studied primarily in nonpolarized, fibroblast-like cells, Myo10 is expressed in vivo in many epithelia-rich tissues, such as kidney. In this study, we investigate the localization and functions of Myo10 in polarized epithelial cells, using Madin-Darby canine kidney II cells as a model system. Calcium-switch experiments demonstrate that, during junction assembly, green fluorescent protein–Myo10 localizes to lateral membrane cell–cell contacts and to filopodia-like structures imaged by total internal reflection fluorescence on the basal surface. Knockdown of Myo10 leads to delayed recruitment of E-cadherin and ZO-1 to junctions, as well as a delay in tight junction barrier formation, as indicated by a delay in the development of peak transepithelial electrical resistance (TER). Although Myo10 knockdown cells eventually mature into monolayers with normal TER, these monolayers do exhibit increased paracellular permeability to fluorescent dextrans. Importantly, knockdown of Myo10 leads to mitotic spindle misorientation, and in three-dimensional culture, Myo10 knockdown cysts exhibit defects in lumen formation. Together these results reveal that Myo10 functions in polarized epithelial cells in junction formation, regulation of paracellular permeability, and epithelial morphogenesis. PMID:22419816
Jo, Javier A; Fang, Qiyin; Papaioannou, Thanassis; Baker, J Dennis; Dorafshar, Amir H; Reil, Todd; Qiao, Jian-Hua; Fishbein, Michael C; Freischlag, Julie A; Marcu, Laura
2006-01-01
We report the application of the Laguerre deconvolution technique (LDT) to the analysis of in-vivo time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data and the diagnosis of atherosclerotic plaques. TR-LIFS measurements were obtained in vivo from normal and atherosclerotic aortas (eight rabbits, 73 areas), and subsequently analyzed using LDT. Spectral and time-resolved features were used to develop four classification algorithms: linear discriminant analysis (LDA), stepwise LDA (SLDA), principal component analysis (PCA), and artificial neural network (ANN). Accurate deconvolution of TR-LIFS in-vivo measurements from normal and atherosclerotic arteries was provided by LDT. The derived Laguerre expansion coefficients reflected changes in the arterial biochemical composition, and provided a means to discriminate lesions rich in macrophages with high sensitivity (>85%) and specificity (>95%). Classification algorithms (SLDA and PCA) using a selected number of features with maximum discriminating power provided the best performance. This study demonstrates the potential of the LDT for in-vivo tissue diagnosis, and specifically for the detection of macrophages infiltration in atherosclerotic lesions, a key marker of plaque vulnerability.
Jo, J A; Fang, Q; Papaioannou, T; Qiao, J H; Fishbein, M C; Beseth, B; Dorafshar, A H; Reil, T; Baker, D; Freischlag, J; Marcu, L
2005-01-01
This study investigates the ability of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) to detect inflammation in atherosclerotic lesion, a key feature of plaque vulnerability. A total of 348 TR-LIFS measurements were taken from carotid plaques of 30 patients, and subsequently analyzed using the Laguerre deconvolution technique. The investigated spots were classified as Early, Fibrotic/Calcified or Inflamed lesions. A stepwise linear discriminant analysis algorithm was developed using spectral and TR features (normalized intensity values and Laguerre expansion coefficients at discrete emission wavelengths, respectively). Features from only three emission wavelengths (390, 450 and 500 nm) were used in the classifier. The Inflamed lesions were discriminated with sensitivity > 80% and specificity > 90 %, when the Laguerre expansion coefficients were included in the feature space. These results indicate that TR-LIFS information derived from the Laguerre expansion coefficients at few selected emission wavelengths can discriminate inflammation in atherosclerotic plaques. We believe that TR-LIFS derived Laguerre expansion coefficients can provide a valuable additional dimension for the detection of vulnerable plaques.
NASA Astrophysics Data System (ADS)
Jo, Javier A.; Fang, Qiyin; Papaioannou, Thanassis; Baker, J. Dennis; Dorafshar, Amir; Reil, Todd; Qiao, Jianhua; Fishbein, Michael C.; Freischlag, Julie A.; Marcu, Laura
2006-03-01
We report the application of the Laguerre deconvolution technique (LDT) to the analysis of in-vivo time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data and the diagnosis of atherosclerotic plaques. TR-LIFS measurements were obtained in vivo from normal and atherosclerotic aortas (eight rabbits, 73 areas), and subsequently analyzed using LDT. Spectral and time-resolved features were used to develop four classification algorithms: linear discriminant analysis (LDA), stepwise LDA (SLDA), principal component analysis (PCA), and artificial neural network (ANN). Accurate deconvolution of TR-LIFS in-vivo measurements from normal and atherosclerotic arteries was provided by LDT. The derived Laguerre expansion coefficients reflected changes in the arterial biochemical composition, and provided a means to discriminate lesions rich in macrophages with high sensitivity (>85%) and specificity (>95%). Classification algorithms (SLDA and PCA) using a selected number of features with maximum discriminating power provided the best performance. This study demonstrates the potential of the LDT for in-vivo tissue diagnosis, and specifically for the detection of macrophages infiltration in atherosclerotic lesions, a key marker of plaque vulnerability.
Jo, Javier A.; Fang, Qiyin; Papaioannou, Thanassis; Baker, J. Dennis; Dorafshar, Amir H.; Reil, Todd; Qiao, Jian-Hua; Fishbein, Michael C.; Freischlag, Julie A.; Marcu, Laura
2007-01-01
We report the application of the Laguerre deconvolution technique (LDT) to the analysis of in-vivo time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data and the diagnosis of atherosclerotic plaques. TR-LIFS measurements were obtained in vivo from normal and atherosclerotic aortas (eight rabbits, 73 areas), and subsequently analyzed using LDT. Spectral and time-resolved features were used to develop four classification algorithms: linear discriminant analysis (LDA), stepwise LDA (SLDA), principal component analysis (PCA), and artificial neural network (ANN). Accurate deconvolution of TR-LIFS in-vivo measurements from normal and atherosclerotic arteries was provided by LDT. The derived Laguerre expansion coefficients reflected changes in the arterial biochemical composition, and provided a means to discriminate lesions rich in macrophages with high sensitivity (>85%) and specificity (>95%). Classification algorithms (SLDA and PCA) using a selected number of features with maximum discriminating power provided the best performance. This study demonstrates the potential of the LDT for in-vivo tissue diagnosis, and specifically for the detection of macrophages infiltration in atherosclerotic lesions, a key marker of plaque vulnerability. PMID:16674179
IR-stimulated visible fluorescence in pink and brown diamond.
Byrne, K S; Chapman, J G; Luiten, A N
2014-03-19
Irradiation of natural pink and brown diamond by middle-ultraviolet light (photon energy ϵ ≥ 4.1 eV ) is seen to induce anomalous fluorescence phenomena at N3 defect centres (structure N3-V). When diamonds primed in this fashion are subsequently exposed to infrared light (even with a delay of many hours), a transient burst of blue N3 fluorescence is observed. The dependence of this IR-triggered fluorescence on pump wavelength and intensity suggest that this fluorescence phenomena is intrinsically related to pink diamond photochromism. An energy transfer process between N3 defects and other defect species can account for both the UV-induced fluorescence intensity changes, and the apparent optical upconversion of IR light. From this standpoint, we consider the implications of this N3 fluorescence behaviour for the current understanding of pink diamond photochromism kinetics.
Blood flow speed of the gastric conduit assessed by indocyanine green fluorescence
Koyanagi, Kazuo; Ozawa, Soji; Oguma, Junya; Kazuno, Akihito; Yamazaki, Yasushi; Ninomiya, Yamato; Ochiai, Hiroki; Tachimori, Yuji
2016-01-01
Abstract Anastomotic leakage is considered as an independent risk factor for postoperative mortality after esophagectomy, and an insufficient blood flow in the reconstructed conduit may be a risk factor of anastomotic leakage. We investigated the clinical significance of blood flow visualization by indocyanine green (ICG) fluorescence in the gastric conduit as a means of predicting the leakage of esophagogastric anastomosis after esophagectomy. Forty patients who underwent an esophagectomy with gastric conduit reconstruction were prospectively investigated. ICG fluorescence imaging of the gastric conduit was detected by a near-infrared camera system during esophagectomy and correlated with clinical parameters or surgical outcomes. In 25 patients, the flow speed of ICG fluorescence in the gastric conduit wall was simultaneous with that of the greater curvature vessels (simultaneous group), whereas in 15 patients this was slower than that of the greater curvature vessels (delayed group). The reduced speed of ICG fluorescence stream in the gastric conduit wall was associated with intraoperative blood loss (P = 0.008). Although anastomotic leakage was not found in the simultaneous group, it occurred in 7 patients of the delayed group (P < 0.001). A flow speed of ICG fluorescence in the gastric conduit wall of 1.76 cm/s or less was determined by a receiver operating characteristic (ROC) curve, identified as a significant independent predictor of anastomotic leakage after esophagectomy (P = 0.004). This preliminary study demonstrates that intraoperative evaluation of blood flow speed by ICG fluorescence in the gastric conduit wall is a useful means to predict the risk of anastomotic leakage after esophagectomy. PMID:27472732
Estuarial fingerprinting through multidimensional fluorescence and multivariate analysis.
Hall, Gregory J; Clow, Kerin E; Kenny, Jonathan E
2005-10-01
As part of a strategy for preventing the introduction of aquatic nuisance species (ANS) to U.S. estuaries, ballast water exchange (BWE) regulations have been imposed. Enforcing these regulations requires a reliable method for determining the port of origin of water in the ballast tanks of ships entering U.S. waters. This study shows that a three-dimensional fluorescence fingerprinting technique, excitation emission matrix (EEM) spectroscopy, holds great promise as a ballast water analysis tool. In our technique, EEMs are analyzed by multivariate classification and curve resolution methods, such as N-way partial least squares Regression-discriminant analysis (NPLS-DA) and parallel factor analysis (PARAFAC). We demonstrate that classification techniques can be used to discriminate among sampling sites less than 10 miles apart, encompassing Boston Harbor and two tributaries in the Mystic River Watershed. To our knowledge, this work is the first to use multivariate analysis to classify water as to location of origin. Furthermore, it is shown that curve resolution can show seasonal features within the multidimensional fluorescence data sets, which correlate with difficulty in classification.
Hong, Seong Cheol; Murale, Dhiraj P; Jang, Se-Young; Haque, Md Mamunul; Seo, Minah; Lee, Seok; Woo, Deok Ha; Kwon, Junghoon; Song, Chang-Seon; Kim, Yun Kyung; Lee, Jun-Seok
2018-06-22
Avian Influenza (AI) caused an annual epidemic outbreak that led to destroying tens of millions of poultry worldwide. Current gold standard AI diagnosis method is an embryonic egg-based hemagglutination assay followed by immunoblotting or PCR sequencing to confirm subtypes. It requires, however, specialized facilities to handle egg inoculation and incubation, and the subtyping methods relied on costly reagents. Here, we demonstrated the first differential sensing approach to distinguish AI subtypes using series of cell lines and fluorescent sensor. Susceptibility of AI virus differs depending on genetic backgrounds of host cells. Thus, we examined cells from different organ origin, and the infection patterns against a panel of cells were utilized for AI virus subtyping. To quantify AI infection, we designed a highly cell-permeable fluorescent superoxide sensor to visualize infection. Though many AI monitoring strategies relied on sophisticated antibody have been extensively studied, our differential sensing strategy successfully proved discriminations of AI subtypes and demonstrated as a useful primary screening platform to monitor a large number of samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Two Effects of Electrical Fields on Chloroplasts 1
Arnold, William A.; Azzi, Jim R.
1977-01-01
An electrical field across a suspension of Chenopodium chloroplasts stimulates the emission of delayed light during the time the field is on. This stimulation can be used to calculate the distance over which the electron moves in the untrapping process that gives the delayed light. An electrical field applied at the time of illumination gives a polarization to the suspension of chloroplasts that lasts for some seconds. This polarization is a new way to study delayed light and fluorescence from chloroplasts. Images PMID:16660112
Suzuki, Azusa; Yanagi, Masaki; Takeda, Takuya; Hudson, Robert H E; Saito, Yoshio
2017-09-26
A new environmentally responsive fluorescent nucleoside, 3-(naphthalen-1-ylethynyl)-3-deaza-2'-deoxyguanosine ( 3nz G), has been synthesized. The nucleoside, 3nz G, exhibited solvatochromic properties and when introduced into ODN probes it was able to recognize 2'-deoxycytidine in target strands by a distinct change in its emission wavelength through probing microenvironmental changes in the DNA minor groove. Thus, 3nz G has the potential for use as a fluorescent probe molecule for micro-structural studies of nucleic acids including the detection of single-base alterations in target DNA sequences.
[Laser Induced Fluorescence Spectroscopic Analysis of Aromatics from One Ring to Four Rings].
Zhang, Peng; Liu, Hai-feng; Yue, Zong-yu; Chen, Bei-ling; Yao, Ming-fa
2015-06-01
In order to distinguish small aromatics preferably, a Nd : YAG Laser was used to supply an excitation laser, which was adjusted to 0.085 J x cm(-2) at 266 nm. Benzene, toluene, naphthalene, phenanthrene, anthracene, pyrene and chrysene were used as the representative of different rings aromatics. The fluorescence emission spectra were researched for each aromatic hydrocarbon and mixtures by Laser induced fluorescence (LIF). Results showed that the rings number determined the fluorescence emission spectra, and the structure with same rings number did not affect the emission fluorescence spectrum ranges. This was due to the fact that the absorption efficiency difference at 266 nm resulted in that the fluorescence intensities of each aromatic hydrocarbon with same rings number were different and the fluorescence intensities difference were more apparently with aromatic ring number increasing. When the absorption efficiency was similar at 266 nm and the concentrations of each aromatic hydrocarbon were same, the fluorescence intensities were increased with aromatic ring number increasing. With aromatic ring number increasing, the fluorescence spectrum and emission peak wavelength were all red-shifted from ultraviolet to visible and the fluorescence spectrum range was also wider as the absorption efficiency was similar. The fluorescence emission spectra from one to four rings could be discriminated in the following wavelengths, 275 to 320 nm, 320 to 375 nm, 375 to 425 nm, 425 to 556 nm, respectively. It can be used for distinguish the type of the polycyclic aromatic hydrocarbons (PAHs) as it exists in single type. As PAHs are usually exist in a variety of different rings number at the same time, the results for each aromatic hydrocarbon may not apply to the aromatic hydrocarbon mixtures. For the aromatic hydrocarbon mixtures, results showed that the one- or two-ring PAHs in mixtures could not be detected by fluorescence as three- or four-ring PAHs existed in mixture. This was caused by radiation energy transfer mechanism, in which the ultraviolet light was lost in mixtures but the fluorescence intensities were increased with the one- or two-ring PAHs adding. When the mixture only contained three- and four-ring PAHs, the fluorescence emission spectrum showed the both characteristics of three- and four-ring PAHs fluorescence. When three- and four-ring PAHs existed in mixtures at the same time, the fluorescence emission spectra were related to each concentration, so the rings number could be discriminated to a certain extent.
Supernumerary ring chromosome 17 identified by fluorescent in situ hybridization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fagan, K.; Edwards, M.
We present a patient with multiple anomalies and severe developmental delay. A small supernumerary ring chromosome was found in 40% of her lymphocyte cells at birth. The origin of the marker chromosome could not be determined by GTG banding, but fluorescent in situ hybridization (FISH) later identified the marker as deriving from chromosome 17. 20 refs., 2 figs., 1 tab.
NASA Astrophysics Data System (ADS)
Lee, Song Eun; Lee, Ho Won; Baek, Hyun Jung; Yun, Tae Jun; Yun, Geum Jae; Kim, Woo Young; Kim, Young Kwan
2016-10-01
Hybrid white organic light-emitting diodes (WOLEDs) were fabricated by applying triplet harvesting (TH) using a green thermally activated delayed fluorescence (TADF) emitter. The triplet exciton of the green TADF emitter can be upconverted to its singlet state. The TH involved energy transfer of triplet exciton from a blue fluorescent emitter to a green TADF and red phosphorescent emitters, where they can decay radiatively. In addition, the triplet exciton of the green TADF emitter was energy transferred to its singlet state for a reverse intersystem crossing by green emission. Enhanced hybrid WOLEDs were demonstrated using an efficient green TADF emitter combined with red phosphorescent and blue fluorescent emitters. Hybrid WOLEDs were fabricated with various hole-electron recombination zones as changing blue emitting layer thicknesses. Among these, hybrid WOLEDs showed a maximum external quantum efficiency of 11.23%, luminous efficiency of 29.20 cd/A, and a power efficiency of 26.21 lm/W. Moreover, the WOLED exhibited electroluminescence spectra with Commission International de L'Éclairage chromaticity of (0.38, 0.36) at 1000 cd/m2 and a color rendering index of 82 at a practical brightness of 20,000 cd/m2.
NASA Astrophysics Data System (ADS)
Zhu, Qiuling; Wen, Keke; Feng, Songyan; Guo, Xugeng; Zhang, Jinglai
2018-03-01
Based upon two thermally activated delayed fluorescence (TADF) emitters 1 and 2, compounds 3-6 have been designed by replacing the carbazol group with the bis(4-biphenyl)amine one (3 and 4) and introducing the electron-withdrawing CF3 group into the acceptor unit of 3 and 4 (5 and 6). It is found that the present calculations predict comparable but relatively large energy differences (approximate 0.5 eV) between the lowest singlet S1 and triplet T1 states (Δ EST) for the six targeted compounds. In order to explain the highly-efficient TADF behavior observed in compounds 1 and 2, the"triplet reservoir" mechanism has been proposed. In addition, the fluorescence rates of all six compounds are very large, in 107-108 orders of magnitude. According to the present calculations, it is a reasonable assumption that the newly designed compounds 3-6 could be considered as the potential TADF emitters, which needs to be further verified by experimental techniques.
NASA Astrophysics Data System (ADS)
Deng, Junquan; Jia, Weiyao; Chen, Yingbing; Liu, Dongyu; Hu, Yeqian; Xiong, Zuhong
2017-03-01
Non-emissive triplet excited states in devices that undergo thermally activated delayed fluorescence (TADF) can be up-converted to singlet excited states via reverse intersystem crossing (RISC), which leads to an enhanced electroluminescence efficiency. Exciton-based fluorescence devices always exhibit a positive magneto-electroluminescence (MEL) because intersystem crossing (ISC) can be suppressed effectively by an external magnetic field. Conversely, TADF devices should exhibit a negative MEL because RISC is suppressed by the external magnetic field. Intriguingly, we observed a positive MEL in TADF devices. Moreover, the sign of the MEL was either positive or negative, and depended on experimental conditions, including doping concentration, current density and temperature. The MEL observed from our TADF devices demonstrated that ISC in the host material and RISC in the guest material coexisted. These competing processes were affected by the experimental conditions, which led to the sign change of the MEL. This work gives important insight into the energy transfer processes and the evolution of excited states in TADF devices.
Doxon, Andrew J; Johnson, David E; Tan, Hong Z; Provancher, William R
2013-01-01
Many of the devices used in haptics research are over-engineered for the task and are designed with capabilities that go far beyond human perception levels. Designing devices that more closely match the limits of human perception will make them smaller, less expensive, and more useful. However, many device-centric perception thresholds have yet to be evaluated. To this end, three experiments were conducted, using one degree-of-freedom contact location feedback device in combination with a kinesthetic display, to provide a more explicit set of specifications for similar tactile-kinesthetic haptic devices. The first of these experiments evaluated the ability of humans to repeatedly localize tactile cues across the fingerpad. Subjects could localize cues to within 1.3 mm and showed bias toward the center of the fingerpad. The second experiment evaluated the minimum perceptible difference of backlash at the tactile element. Subjects were able to discriminate device backlash in excess of 0.46 mm on low-curvature models and 0.93 mm on high-curvature models. The last experiment evaluated the minimum perceptible difference of system delay between user action and device reaction. Subjects were able to discriminate delays in excess of 61 ms. The results from these studies can serve as the maximum (i.e., most demanding) device specifications for most tactile-kinesthetic haptic systems.
NASA Astrophysics Data System (ADS)
Pawełczak, I. A.; Ouedraogo, S. A.; Glenn, A. M.; Wurtz, R. E.; Nakae, L. F.
2013-05-01
Pulse shape discrimination capability based on the charge integration has been investigated for liquid scintillator EJ-309. The effectiveness of neutron-γ discrimination in 4-in. diameter and 3-in. thick EJ-309 cells coupled with 3-in. photomultiplier tubes has been carefully studied in the laboratory environment and compared to the commonly used EJ-301 liquid scintillator formulation. Influences of distortions in pulse shape caused by 13.7-m long cables necessary for some remote operations have been examined. The parameter space for an effective neutron-γ discrimination for these assays, such as position and width of a gate used for integration of the delayed light, has been explored.
Song, Yang; Cai, Weidong; Feng, David Dagan; Chen, Mei
2013-01-01
Automated segmentation of cell nuclei in microscopic images is critical to high throughput analysis of the ever increasing amount of data. Although cell nuclei are generally visually distinguishable for human, automated segmentation faces challenges when there is significant intensity inhomogeneity among cell nuclei or in the background. In this paper, we propose an effective method for automated cell nucleus segmentation using a three-step approach. It first obtains an initial segmentation by extracting salient regions in the image, then reduces false positives using inter-region feature discrimination, and finally refines the boundary of the cell nuclei using intra-region contrast information. This method has been evaluated on two publicly available datasets of fluorescence microscopic images with 4009 cells, and has achieved superior performance compared to popular state of the art methods using established metrics.
Secured Optical Communications Using Quantum Entangled Two-Photon Transparency Modulation
NASA Technical Reports Server (NTRS)
Nguyen, Quang-Viet (Inventor); Kojima, Jun (Inventor); Lekki, John (Inventor)
2015-01-01
A system and method is disclosed wherein optical signals are coded in a transmitter by tuning or modulating the interbeam delay time (which modulates the fourth-order coherence) between pairs of entangled photons. The photon pairs are either absorbed or not absorbed (transparent) by an atomic or molecular fluorescer in a receiver, depending on the inter-beam delay that is introduced in the entangled photon pairs. Upon the absorption, corresponding fluorescent optical emissions follow at a certain wavelength, which are then detected by a photon detector. The advantage of the disclosed system is that it eliminates a need of a coincidence counter to realize the entanglement-based secure optical communications because the absorber acts as a coincidence counter for entangled photon pairs.
Sensitized phosphorescence of benzil-doped ladder-type methyl-poly(para-phenylene).
Bagnich, S A; Bässler, H; Neher, D
2004-11-08
The delayed luminescence and phosphorescence of ladder-type methyl-poly(para-phenylene) (MeLPPP) doped with benzil at a concentration of 20% by weight has been measured. The introduction of benzil leads to a dramatic reduction of the polymer singlet emission. At the same time, a new band with maximum at 611 nm appears, corresponding to the phosphorescence of MeLPPP. The phosphorescence decay on the short time scale is close to an exponential law with a time decay of 15 ms. This indicates that benzil can efficiently sensitize the phosphorescence of the polymer. In addition, a broad and featureless emission is observed in the delayed luminescence spectra of benzil-doped MeLPPP, which is attributed to an exciplex formed between the polymer host and the dopant. We further observe that the delayed fluorescence is enhanced by the addition of benzil. It is concluded that the delayed fluorescence of benzil-doped MeLPPP is mainly due to the annihilation of triplet excitons on the polymer. Finally, efficient triplet-triplet energy transfer from the benzil-doped polymer to the red-emitting phosphorescent dye Pt(II)octaethylporphyrin is established. Copyright 2004 American Institute of Physics.
Motor Oil Classification Based on Time-Resolved Fluorescence
Mu, Taotao; Chen, Siying; Zhang, Yinchao; Guo, Pan; Chen, He; Meng, Fandong
2014-01-01
A time-resolved fluorescence (TRF) technique is presented for classifying motor oils. The system is constructed with a third harmonic Nd:YAG laser, a spectrometer, and an intensified charge coupled device (ICCD) camera. Steady-state and time-resolved fluorescence (TRF) measurements are reported for several motor oils. It is found that steady-state fluorescence is insufficient to distinguish the motor oil samples. Then contour diagrams of TRF intensities (CDTRFIs) are acquired to serve as unique fingerprints to identify motor oils by using the distinct TRF of motor oils. CDTRFIs are preferable to steady-state fluorescence spectra for classifying different motor oils, making CDTRFIs a particularly choice for the development of fluorescence-based methods for the discrimination and characterization of motor oils. The two-dimensional fluorescence contour diagrams contain more information, not only the changing shapes of the LIF spectra but also the relative intensity. The results indicate that motor oils can be differentiated based on the new proposed method, which provides reliable methods for analyzing and classifying motor oils. PMID:24988439
Simultaneous multicolor imaging of wide-field epi-fluorescence microscopy with four-bucket detection
Park, Kwan Seob; Kim, Dong Uk; Lee, Jooran; Kim, Geon Hee; Chang, Ki Soo
2016-01-01
We demonstrate simultaneous imaging of multiple fluorophores using wide-field epi-fluorescence microscopy with a monochrome camera. The intensities of the three lasers are modulated by a sinusoidal waveform in order to excite each fluorophore with the same modulation frequency and a different time-delay. Then, the modulated fluorescence emissions are simultaneously detected by a camera operating at four times the excitation frequency. We show that two different fluorescence beads having crosstalk can be clearly separated using digital processing based on the phase information. In addition, multiple organelles within multi-stained single cells are shown with the phase mapping method, demonstrating an improved dynamic range and contrast compared to the conventional fluorescence image. These findings suggest that wide-field epi-fluorescence microscopy with four-bucket detection could be utilized for high-contrast multicolor imaging applications such as drug delivery and fluorescence in situ hybridization. PMID:27375944
Evaluating the Precision of Auditory Sensory Memory as an Index of Intrusion in Tinnitus.
Barrett, Doug J K; Pilling, Michael
The purpose of this study was to investigate the potential of measures of auditory short-term memory (ASTM) to provide a clinical measure of intrusion in tinnitus. Response functions for six normal listeners on a delayed pitch discrimination task were contrasted in three conditions designed to manipulate attention in the presence and absence of simulated tinnitus: (1) no-tinnitus, (2) ignore-tinnitus, and (3) attend-tinnitus. Delayed pitch discrimination functions were more variable in the presence of simulated tinnitus when listeners were asked to divide attention between the primary task and the amplitude of the tinnitus tone. Changes in the variability of auditory short-term memory may provide a novel means of quantifying the level of intrusion associated with the tinnitus percept during listening.
Maity, Santu; Parshi, Nira; Prodhan, Chandraday; Chaudhuri, Keya; Ganguly, Jhuma
2018-08-01
A three-dimensional fluorescent hydrogel based on chitosan, polyvinyl alcohol and 9-anthraldehyde (ChPA) has been successfully designed and synthesized for the selective detection and discrimination of Fe 3+ and Fe 2+ in aqueous environment. The unique characteristics of ChPA has been confirmed by the Fourier-transform infrared spectroscopy (FTIR), rheological measurement, scanning electron microscopy (SEM), thermogravimetry and differential thermogravimetry (TG-DTG), ultraviolet-visible spectroscopy (UV-vis), fluorescence studies, transmission electron microscopy (TEM), energy dispersive x-ray spectroscopy (EDX), x-ray diffraction (XRD) and dynamic light scattering (DLS). The emission intensity at 516 nm of the hydrogel has been enhanced remarkably with the addition of Fe 3+ due to the inhibition of the photoinduced electron transfer (PET) process. However, it gets strongly quenched in the case of Fe 2+ owing to chelation enhanced quenching (CHEQ). The probe (ChPA) causes no significant change in the fluorescence and becomes highly specific and sensitive towards Fe 3+ and Fe 2+ compared to other interfering heavy and transition metal ions (HTM). The detection limits of the sensor for the Fe 3+ and Fe 2+ are 0.124 nM and 0.138 nM, respectively. The probe is also promising as a selective sensor for the Fe 3+ and Fe 2+ in the fluorescence imaging of living cells. Thus, such a probe opens up new opportunities to improve the chitosan based fluorescent chemosensor having biocompatibility, biodegradability, sufficient thermal stability and stability in a wide pH range. Copyright © 2018 Elsevier Ltd. All rights reserved.
Derrien, Morgane; Kim, Min-Seob; Ock, Giyoung; Hong, Seongjin; Cho, Jinwoo; Shin, Kyung-Hoon; Hur, Jin
2018-03-15
The two popular source tracing tools of stable isotope ratios (δ 13 C and δ 15 N) and fluorescence spectroscopy were used to estimate the relative source contributions to sediment organic matter (SeOM) at five different river sites in an agricultural-forested watershed (Soyang Lake watershed), and their capabilities for the source assignment were compared. Bulk sediments were used for the stable isotopes, while alkaline extractable organic matter (AEOM) from sediments was used to obtain fluorescent indices for SeOM. Several source discrimination indices were fully compiled for a range of the SeOM sources distributed in the catchments of the watershed, which included soils, forest leaves, crop (C3 and C4) and riparian plants, periphyton, and organic fertilizers. The relative source contributions to the river sediment samples were estimated via end member mixing analysis (EMMA) based on several selected discrimination indices. The EMMA based on the isotopes demonstrated that all sediments were characterized by a medium to a high contribution of periphyton ranging from ~30% to 70% except for one site heavily affected by forest and agricultural fields with relatively high contributions of terrestrial materials. The EMMA based on fluorescence parameters, however, did not show similar results with low contributions from forest leaf and periphyton. The characteristics of the studied watershed were more consistent with the source contributions determined by the isotope ratios. The discrepancy in the EMMA capability for source assignments between the two analytical tools can be explained by the limited analytical window of fluorescence spectroscopy for non-fluorescent dissolved organic matter (FDOM) and the inability of AEOM to represent original bulk particulate organic matter (POM). Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Parker, Lindsay M.; Staikopoulos, Vicky; Cordina, Nicole M.; Sayyadi, Nima; Hutchinson, Mark R.; Packer, Nicolle H.
2016-03-01
Despite significant advancement in the methodology used to conjugate, incorporate and visualize fluorescent molecules at the cellular and tissue levels, biomedical imaging predominantly relies on the limitations of established fluorescent molecules such as fluorescein, cyanine and AlexaFluor dyes or genetic incorporation of fluorescent proteins by viral or other means. These fluorescent dyes and conjugates are highly susceptible to photobleaching and compete with cellular autofluorescence, making biomedical imaging unreliable, difficult and time consuming in many cases. In addition, some proteins have low copy numbers and/or poor antibody recognition, further making detection and imaging difficult. We are developing better methods for imaging central nervous system neuroinflammatory markers using targeted mRNA transcripts labelled with fluorescent nanodiamonds or lanthanide chelates. These tags have increased signal and photostability and can also discriminate against tissue/cell autofluorescence. Brains and spinal cords from BALB/c mice with a chronic constriction model of neuropathic pain (neuroinflammation group) or that have undergone sham surgeries (control group) were collected. A subset of brains and spinal cords were perfused and fixed with paraformaldehyde (n=3 sham and n=3 pain groups) prior to sectioning and in situ hybridization using nanodiamond or lanthanide chelate conjugated complementary RNA probes. Another subset of brains and spinal cords from the same cohort of animals were perfused and processed for CLARITY hydrogel based clearing prior to in situ hybridization with the same probes. We will present our findings on the photostability, sensitivity and discrimination from background tissue autofluorescence of our novel RNA probes, compared to traditional fluorophore tags.
Fleming, Stephen A; Dilger, Ryan N
2017-03-15
Novelty preference paradigms have been widely used to study recognition memory and its neural substrates. The piglet model continues to advance the study of neurodevelopment, and as such, tasks that use novelty preference will serve especially useful due to their translatable nature to humans. However, there has been little use of this behavioral paradigm in the pig, and previous studies using the novel object recognition paradigm in piglets have yielded inconsistent results. The current study was conducted to determine if piglets were capable of displaying a novelty preference. Herein a series of experiments were conducted using novel object recognition or location in 3- and 4-week-old piglets. In the novel object recognition task, piglets were able to discriminate between novel and sample objects after delays of 2min, 1h, 1 day, and 2 days (all P<0.039) at both ages. Performance was sex-dependent, as females could perform both 1- and 2-day delays (P<0.036) and males could perform the 2-day delay (P=0.008) but not the 1-day delay (P=0.347). Furthermore, 4-week-old piglets and females tended to exhibit greater exploratory behavior compared with males. Such performance did not extend to novel location recognition tasks, as piglets were only able to discriminate between novel and sample locations after a short delay (P>0.046). In conclusion, this study determined that piglets are able to perform the novel object and location recognition tasks at 3-to-4 weeks of age, however performance was dependent on sex, age, and delay. Copyright © 2016 Elsevier B.V. All rights reserved.
Are the effects of benzodiazepines on discrimination and punishment dissociable?
Hodges, H; Green, S
1987-01-01
Studies have shown that benzodiazepines (BZs) both disrupt discrimination and increase resistance to punishment. Using a delayed response task, we provide evidence that effects of BZs on discrimination cannot be fully explained by deficits in either short or long term memory, or by intolerance for delay of reward. A schedule with rewarded, nonrewarded (Time out: TO) and conflict components was used to investigate effects in rats of compounds active at the BZ receptor on successive discrimination and punished responding in parallel. The GABA transaminase inhibitor ethanolamine-O-sulphate exerted additive effects with chlordiazepoxide (CDP) on punished but not TO responding. Both GABA and CDP injected into the amygdala selectively increased conflict rates, but with peripheral treatment CDP also increased TO rates. Two inverse BZ agonists, CGS 8216 and FG 7142 antagonzied the anti-conflict effects of GABA and CDP, given within the amygdala or peripherally, but the increase in TO rates induced by systemic CDP was counteracted only by peripheral treatments. These compounds also reduced rates of conflict responding below baseline, consistent with anxiogenic activity. Effects of the BZ antagonist Ro 15-1788 were broadly similar to those of the inverse agonists, except that it did not antagonise the anti-conflict action of intra-amygdaloid GABA, nor significantly reduce punished responding at the single dose used. We conclude from these results that the anti-conflict effects of BZs are mediated by a GABAergic amygdaloid mechanism, but that the same mechanism is not involved in BZ effects on discrimination.
White, K G; Wixted, J T
1999-01-01
We present a new model of remembering in the context of conditional discrimination. For procedures such as delayed matching to sample, the effect of the sample stimuli at the time of remembering is represented by a pair of Thurstonian (normal) distributions of effective stimulus values. The critical assumption of the model is that, based on prior experience, each effective stimulus value is associated with a ratio of reinforcers obtained for previous correct choices of the comparison stimuli. That ratio determines the choice that is made on the basis of the matching law. The standard deviations of the distributions are assumed to increase with increasing retention-interval duration, and the distance between their means is assumed to be a function of other factors that influence overall difficulty of the discrimination. It is a behavioral model in that choice is determined by its reinforcement history. The model predicts that the biasing effects of the reinforcer differential increase with decreasing discriminability and with increasing retention-interval duration. Data from several conditions using a delayed matching-to-sample procedure with pigeons support the predictions. PMID:10028693
Fluorescence multispectral imaging-based diagnostic system for atherosclerosis.
Ho, Cassandra Su Lyn; Horiuchi, Toshikatsu; Taniguchi, Hiroaki; Umetsu, Araya; Hagisawa, Kohsuke; Iwaya, Keiichi; Nakai, Kanji; Azmi, Amalina; Zulaziz, Natasha; Azhim, Azran; Shinomiya, Nariyoshi; Morimoto, Yuji
2016-08-20
Composition of atherosclerotic arterial walls is rich in lipids such as cholesterol, unlike normal arterial walls. In this study, we aimed to utilize this difference to diagnose atherosclerosis via multispectral fluorescence imaging, which allows for identification of fluorescence originating from the substance in the arterial wall. The inner surface of extracted arteries (rabbit abdominal aorta, human coronary artery) was illuminated by 405 nm excitation light and multispectral fluorescence images were obtained. Pathological examination of human coronary artery samples were carried out and thickness of arteries were calculated by measuring combined media and intima thickness. The fluorescence spectra in atherosclerotic sites were different from those in normal sites. Multiple regions of interest (ROI) were selected within each sample and a ratio between two fluorescence intensity differences (where each intensity difference is calculated between an identifier wavelength and a base wavelength) from each ROI was determined, allowing for discrimination of atherosclerotic sites. Fluorescence intensity and thickness of artery were found to be significantly correlated. These results indicate that multispectral fluorescence imaging provides qualitative and quantitative evaluations of atherosclerosis and is therefore a viable method of diagnosing the disease.
Measurement of the fluorescence of crop residues: A tool for controlling soil erosion
NASA Technical Reports Server (NTRS)
Daughtry, C. S. T.; Mcmurtrey, J. E., III; Chappelle, E. W.; Hunter, W. J.
1994-01-01
Management of crop residues, the portion of a crop left in the field after harvest, is an important conservation practice for minimizing soil erosion and for improving water quality. Quantification of crop residue cover is required to evaluate the effectiveness of conservation tillage practices. Methods are needed to quantify residue cover that are rapid, accurate, and objective. The fluorescence of crop residue was found to be a broadband phenomenon with emission maxima at 420 to 495 nm for excitations of 350 to 420 nm. Soils had low intensity broadband emissions over the 400 to 690 nm region for excitations of 300 to 600 nm. The range of relative fluorescence intensities for the crop residues was much greater than the fluorescence observed of the soils. As the crop residues decompose their blue fluorescence values approach the fluorescence of the soil. Fluorescence techniques are concluded to be less ambiguous and better suited for discriminating crop residues and soils than reflectance methods. If properly implemented, fluorescence techniques can be used to quantify, not only crop residue cover, but also photosynthetic efficiency in the field.
NADPH as a potential intrinsic probe for tumour margin estimation
NASA Astrophysics Data System (ADS)
Stewart, Hazel; Hupp, Ted R.; Birch, David J. S.
2018-03-01
The fluorescent properties of the reduced coenzyme NADH and its phosphorylated derivative (NADPH) have been explored in order to assess their potential as an intrinsic probe for cancer surgery. NADPH production is increased in cancer cells to quench reactive oxygen species and meet higher demands for biosynthesis, and has attractive fluorescent properties such as emission towards the visible part of the spectrum and a relatively long fluorescence lifetime upon binding to enzymes ( 1 - 6.5 ns) that helps discriminate against other endogenous species. Different environmental effects on NAD(P)H fluorescence are reported here, including an increase in lifetime upon oxygen removal, an ability to retain its fluorescent properties in a complex medium (a silica phantom) and its fluorescence lifetime also being distinguishable in a cell environment. In addition, the development of a miniaturized liquid light guide filter-based timecorrelated single photon counting fluorescence lifetime system is reported as a step towards time-resolved visual imaging in cancer surgery. This system has been demonstrated as being capable of accurately measuring NAD(P)H fluorescence lifetimes in both simple solvent and cellular environments.
NASA Astrophysics Data System (ADS)
Pachaiappan, Rekha; Prakasarao, Aruna; Manoharan, Yuvaraj; Dornadula, Koteeswaran; Singaravelu, Ganesan
2017-02-01
During metabolism the metabolites such as hormones, proteins and enzymes were released in to the blood stream by the cells. These metabolites reflect any change that occurs due to any disturbances in normal metabolic function of the human system. This was well observed with the altered spectral signatures observed with fluorescence spectroscopic technique. Previously many have reported on the significance of native fluorescence spectroscopic method in the diagnosis of cancer. As fluorescence spectroscopy is sensitive and simple, it has complementary techniques such as excitation-emission matrix, synchronous and polarization. The fluorescence polarization measurement provides details about any association or binding reactions and denaturing effects that occurs due to change in the micro environment of cells and tissues. In this study, we have made an attempt in the diagnosis of oral cancer at 405 nm excitation using fluorescence polarization measurement. The fluorescence anisotropic values calculated from polarized fluorescence spectral data of normal and oral cancer subjects yielded a good accuracy when analyzed with linear discriminant analysis based artificial neural network. The results will be discussed in detail.
Scholz, Marek; Biehl, Anna-Louisa; Dědic, Roman; Hála, Jan
2015-04-01
The present work provides a proof-of-concept that the singlet oxygen-sensitized delayed fluorescence (SOSDF) can be detected from individual living mammalian cells in a time-resolved microscopy experiment. To this end, 3T3 mouse fibroblasts incubated with 100 μM TPPS4 or TMPyP were used and the microsecond kinetics of the delayed fluorescence (DF) were recorded. The analysis revealed that SOSDF is the major component of the overall DF signal. The microscopy approach enables precise control of experimental conditions - the DF kinetics are clearly influenced by the presence of the (1)O2 quencher (sodium azide), H2O/D2O exchange, and the oxygen concentration. Analysis of SOSDF kinetics, which was reconstructed as a difference DF kinetics between the unquenched and the NaN3-quenched samples, provides a cellular (1)O2 lifetime of τΔ = 1-2 μs and a TPPS4 triplet lifetime of τT = 22 ± 5 μs in agreement with previously published values. The short SOSDF acquisition times, typically in the range of tens of seconds, enable us to study the dynamic cellular processes. It is shown that SOSDF lifetimes increase during PDT-like treatment, which may provide valuable information about changes of the intracellular microenvironment. SOSDF is proposed and evaluated as an alternative tool for (1)O2 detection in biological systems.
Pigeons' Memory for Number of Events: Effects of Intertrial Interval and Delay Interval Illumination
ERIC Educational Resources Information Center
Hope, Chris; Santi, Angelo
2004-01-01
In Experiment 1, pigeons were trained at a 0-s baseline delay to discriminate sequences of light flashes (illumination of the feeder) that varied in number but not time (2f/4s and 8f/4s). During training, the intertrial interval was illuminated by the houselight for Group Light, but it was dark for Group Dark. Testing conducted with dark delay…
Mair, Robert G; Miller, Rikki L A; Wormwood, Benjamin A; Francoeur, Miranda J; Onos, Kristen D; Gibson, Brett M
2015-07-01
Although medial thalamus is well established as a site of pathology associated with global amnesia, there is uncertainty about which structures are critical and how they affect memory function. Evidence from human and animal research suggests that damage to the mammillothalamic tract and the anterior, mediodorsal (MD), midline (M), and intralaminar (IL) nuclei contribute to different signs of thalamic amnesia. Here we focus on MD and the adjacent M and IL nuclei, structures identified in animal studies as critical nodes in prefrontal cortex (PFC)-related pathways that are necessary for delayed conditional discrimination. Recordings of PFC neurons in rats performing a dynamic delayed non-matching-to position (DNMTP) task revealed discrete populations encoding information related to planning, execution, and outcome of DNMTP-related actions and delay-related activity signaling previous reinforcement. Parallel studies recording the activity of MD and IL neurons and examining the effects of unilateral thalamic inactivation on the responses of PFC neurons demonstrated a close coupling of central thalamic and PFC neurons responding to diverse aspects of DNMTP and provide evidence that thalamus interacts with PFC neurons to give rise to complex goal-directed behavior exemplified by the DNMTP task. Copyright © 2015 Elsevier Ltd. All rights reserved.
Buzzini, Patrick; Massonnet, Genevieve
2013-11-01
Raman spectroscopy has been applied to characterize fiber dyes and determine the discriminating ability of the method. Black, blue, and red acrylic, cotton, and wool samples were analyzed. Four excitation sources were used to obtain complementary responses in the case of fluorescent samples. Fibers that did not provide informative spectra using a given laser were usually detected using another wavelength. For any colored acrylic, the 633-nm laser did not provide Raman information. The 514-nm laser provided the highest discrimination for blue and black cotton, but half of the blue cottons produced noninformative spectra. The 830-nm laser exhibited the highest discrimination for red cotton. Both visible lasers provided the highest discrimination for black and blue wool, and NIR lasers produced remarkable separation for red and black wool. This study shows that the discriminating ability of Raman spectroscopy depends on the fiber type, color, and the laser wavelength. © 2013 American Academy of Forensic Sciences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirvonen, Liisa M.; Le Marois, Alix; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk
We perform wide-field time-correlated single photon counting-based fluorescence lifetime imaging (FLIM) with a crossed delay line anode image intensifier, where the pulse propagation time yields the photon position. This microchannel plate-based detector was read out with conventional fast timing electronics and mounted on a fluorescence microscope with total internal reflection (TIR) illumination. The picosecond time resolution of this detection system combines low illumination intensity of microwatts with wide-field data collection. This is ideal for fluorescence lifetime imaging of cell membranes using TIR. We show that fluorescence lifetime images of living HeLa cells stained with membrane dye di-4-ANEPPDHQ exhibit a reducedmore » lifetime near the coverslip in TIR compared to epifluorescence FLIM.« less
Reisinger, Jürgen; Rumpler, Silvia; Lion, Thomas; Ambros, Peter F
2006-04-01
For many Epstein-Barr virus (EBV)-associated malignancies, it is still a matter of controversy whether infected cells harbor episomal or chromosomally integrated EBV genomes or both. It is well established that the expression of EBV genes per se carries oncogenic potential, but the discrimination between episomal and integrated forms is of great relevance because integration events can contribute to the oncogenic properties of EBV, whereas host cells that exclusively harbor viral episomes may not carry the risks mediated by chromosomal integration. This notion prompted us to establish a reliable technique that not only allows to unequivocally discriminate episomal from integrated EBV DNA, but also provides detailed insights into the genomic organization of the virus. Here, we show that dynamic molecular combing of host cell DNA combined with fluorescence in situ hybridization (FISH) using EBV-specific DNA probes facilitate unambiguous discrimination of episomal from integrated viral DNA. Furthermore, the detection of highly elongated internal repeat 1 (IR1) sequences provides evidence that this method permits detection of major genomic alterations within the EBV genome. Thus, fiber FISH may also provide valuable insights into the genomic organization of viral genomes other than EBV.
Xiao, Xianjin; Wu, Tongbo; Xu, Lei; Chen, Wei
2017-01-01
Abstract Genetic mutations are important biomarkers for cancer diagnostics and surveillance. Preferably, the methods for mutation detection should be straightforward, highly specific and sensitive to low-level mutations within various sequence contexts, fast and applicable at room-temperature. Though some of the currently available methods have shown very encouraging results, their discrimination efficiency is still very low. Herein, we demonstrate a branch-migration based fluorescent probe (BM probe) which is able to identify the presence of known or unknown single-base variations at abundances down to 0.3%-1% within 5 min, even in highly GC-rich sequence regions. The discrimination factors between the perfect-match target and single-base mismatched target are determined to be 89–311 by measurement of their respective branch-migration products via polymerase elongation reactions. The BM probe not only enabled sensitive detection of two types of EGFR-associated point mutations located in GC-rich regions, but also successfully identified the BRAF V600E mutation in the serum from a thyroid cancer patient which could not be detected by the conventional sequencing method. The new method would be an ideal choice for high-throughput in vitro diagnostics and precise clinical treatment. PMID:28201758
Discrimination and quantification of autofluorescence spectra of human lung cells
NASA Astrophysics Data System (ADS)
Rahmani, Mahya; Khani, Mohammad Mehdi; Khazaei Koohpar, Zeinab; Molik, Paria
2016-10-01
To study laser-induced autofluorescence spectroscopy of the human lung cell line, we evaluated the native fluorescence properties of cancer QU-DB and normal MRC-5 human lung cells during continuous exposure to 405 nm laser light. Two emission bands centered at ~470 nm and ~560 nm were observed. These peaks are most likely attributable to mitochondrial fluorescent reduced nicotinamide adenine dinucleotide and riboflavin fluorophores, respectively. This article highlights lung cell autofluorescence characterization and signal discrimination by collective investigation of different spectral features. The absolute intensity, the spectral shape factor or redox ratio, the full width of half-maximum and the full width of quarter maximum was evaluated. Moreover, the intensity ratio, the area under the peak and the area ratio as a contrast factor for normal and cancerous cells were also calculated. Among all these features it seems that the contrast factor precisely and significantly discriminates the spectral differences of normal and cancerous lung cells. On the other hand, the relative quantum yield for both cell types were found by comparing the quantum yield of an unknown compound with known fluorescein sodium as a reference solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Tony C.; Congreve, Daniel N.; Baldo, Marc A., E-mail: baldo@mit.edu
2015-07-20
The ability to upconvert light is useful for a range of applications, from biological imaging to solar cells. But modern technologies have struggled to upconvert incoherent incident light at low intensities. Here, we report solid state photon upconversion employing triplet-triplet exciton annihilation in an organic semiconductor, sensitized by a thermally activated-delayed fluorescence (TADF) dye. Compared to conventional phosphorescent sensitizers, the TADF dye maximizes the wavelength shift in upconversion due to its small singlet-triplet splitting. The efficiency of energy transfer from the TADF dye is 9.1%, and the conversion yield of sensitizer exciton pairs to singlet excitons in the annihilator ismore » 1.1%. Our results demonstrate upconversion in solid state geometries and with non-heavy metal-based sensitizer materials.« less
Zhang, Lijun; Huang, Xinyan; Cao, Yuan; Xin, Yunhong; Ding, Liping
2017-12-22
Enormous effort has been put to the detection and recognition of various heavy metal ions due to their involvement in serious environmental pollution and many major diseases. The present work has developed a single fluorescent sensor ensemble that can distinguish and identify a variety of heavy metal ions. A pyrene-based fluorophore (PB) containing a metal ion receptor group was specially designed and synthesized. Anionic surfactant sodium dodecyl sulfate (SDS) assemblies can effectively adjust its fluorescence behavior. The selected binary ensemble based on PB/SDS assemblies can exhibit multiple emission bands and provide wavelength-based cross-reactive responses to a series of metal ions to realize pattern recognition ability. The combination of surfactant assembly modulation and the receptor for metal ions empowers the present sensor ensemble with strong discrimination power, which could well differentiate 13 metal ions, including Cu 2+ , Co 2+ , Ni 2+ , Cr 3+ , Hg 2+ , Fe 3+ , Zn 2+ , Cd 2+ , Al 3+ , Pb 2+ , Ca 2+ , Mg 2+ , and Ba 2+ . Moreover, this single sensing ensemble could be further applied for identifying different brands of drinking water.
Ruoff, Kaspar; Luginbühl, Werner; Künzli, Raphael; Bogdanov, Stefan; Bosset, Jacques Olivier; von der Ohe, Katharina; von der Ohe, Werner; Amado, Renato
2006-09-06
Front-face fluorescence spectroscopy, directly applied on honey samples, was used for the authentication of 11 unifloral and polyfloral honey types (n = 371 samples) previously classified using traditional methods such as chemical, pollen, and sensory analysis. Excitation spectra (220-400 nm) were recorded with the emission measured at 420 nm. In addition, emission spectra were recorded between 290 and 500 nm (excitation at 270 nm) as well as between 330 and 550 nm (excitation at 310 nm). A total of four different spectral data sets were considered for data analysis. Chemometric evaluation of the spectra included principal component analysis and linear discriminant analysis; the error rates of the discriminant models were calculated by using Bayes' theorem. They ranged from <0.1% (polyfloral and chestnut honeys) to 9.9% (fir honeydew honey) by using single spectral data sets and from <0.1% (metcalfa honeydew, polyfloral, and chestnut honeys) to 7.5% (lime honey) by combining two data sets. This study indicates that front-face fluorescence spectroscopy is a promising technique for the authentication of the botanical origin of honey and may also be useful for the determination of the geographical origin within the same unifloral honey type.
Inferring diffusion in single live cells at the single-molecule level
Robson, Alex; Burrage, Kevin; Leake, Mark C.
2013-01-01
The movement of molecules inside living cells is a fundamental feature of biological processes. The ability to both observe and analyse the details of molecular diffusion in vivo at the single-molecule and single-cell level can add significant insight into understanding molecular architectures of diffusing molecules and the nanoscale environment in which the molecules diffuse. The tool of choice for monitoring dynamic molecular localization in live cells is fluorescence microscopy, especially so combining total internal reflection fluorescence with the use of fluorescent protein (FP) reporters in offering exceptional imaging contrast for dynamic processes in the cell membrane under relatively physiological conditions compared with competing single-molecule techniques. There exist several different complex modes of diffusion, and discriminating these from each other is challenging at the molecular level owing to underlying stochastic behaviour. Analysis is traditionally performed using mean square displacements of tracked particles; however, this generally requires more data points than is typical for single FP tracks owing to photophysical instability. Presented here is a novel approach allowing robust Bayesian ranking of diffusion processes to discriminate multiple complex modes probabilistically. It is a computational approach that biologists can use to understand single-molecule features in live cells. PMID:23267182
Plasma-assisted quadruple-channel optosensing of proteins and cells with Mn-doped ZnS quantum dots.
Li, Chenghui; Wu, Peng; Hou, Xiandeng
2016-02-21
Information extraction from nano-bio-systems is crucial for understanding their inner molecular level interactions and can help in the development of multidimensional/multimodal sensing devices to realize novel or expanded functionalities. The intrinsic fluorescence (IF) of proteins has long been considered as an effective tool for studying protein structures and dynamics, but not for protein recognition analysis partially because it generally contributes to the fluorescence background in bioanalysis. Here we explored the use of IF as the fourth channel optical input for a multidimensional optosensing device, together with the triple-channel optical output of Mn-doped ZnS QDs (fluorescence from ZnS host, phosphorescence from Mn(2+) dopant, and Rayleigh light scattering from the QDs), to dramatically improve the protein recognition and discrimination resolution. To further increase the cross-reactivity of the multidimensional optosensing device, plasma modification of proteins was explored to enhance the IF difference as well as their interactions with Mn-doped ZnS QDs. Such a sensor device was demonstrated for highly discriminative and precise identification of proteins in human serum and urine samples, and for cancer and normal cells as well.
Hutsell, Blake A; Banks, Matthew L
2017-12-01
Emerging human laboratory and preclinical drug self-administration data suggest that a history of contingent abused drug exposure impairs performance in operant discrimination procedures, such as delayed nonmatching-to-sample (DNMTS), that are hypothesized to assess components of executive function. However, these preclinical discrimination studies have exclusively used food as the reinforcer and the effects of drugs as reinforcers in these operant procedures are unknown. The present study determined effects of contingent intravenous remifentanil injections on DNMTS performance hypothesized to assess 1 aspect of executive function, working memory. Daily behavioral sessions consisted of 2 components with sequential intravenous remifentanil (0, 0.01-1.0 μg/kg/injection) or food (0, 1-10 pellets) availability in nonopioid dependent male rhesus monkeys (n = 3). Remifentanil functioned as a reinforcer in the DNMTS procedure. Similar delay-dependent DNMTS accuracy was observed under both remifentanil- and food-maintained components, such that higher accuracies were maintained at shorter (0.1-1.0 s) delays and lower accuracies approaching chance performance were maintained at longer (10-32 s) delays. Remifentanil maintained significantly lower initial DNMTS accuracy compared to food. Reinforcer magnitude was not an important determinant of DNMTS accuracy for either remifentanil or food. These results extend the range of experimental procedures under which drugs function as reinforcers. Furthermore, the selective remifentanil-induced decrease in initial DNMTS accuracy is consistent with a selective impairment of attentional, but not memorial, processes. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Pump-probe micro-spectroscopy by means of an ultra-fast acousto-optics delay line.
Audier, Xavier; Balla, Naveen; Rigneault, Hervé
2017-01-15
We demonstrate femtosecond pump-probe transient absorption spectroscopy using a programmable dispersive filter as an ultra-fast delay line. Combined with fast synchronous detection, this delay line allows for recording of 6 ps decay traces at 34 kHz. With such acquisition speed, we perform single point pump-probe spectroscopy on bulk samples in 80 μs and hyperspectral pump-probe imaging over a field of view of 100 μm in less than a second. The usability of the method is illustrated in a showcase experiment to image and discriminate between two pigments in a mixture.
Shi, Yupeng; Pan, Yi; Zhang, Heng; Zhang, Zhaomin; Li, Mei-Jin; Yi, Changqing; Yang, Mengsu
2014-06-15
Glutathione (GSH) plays key roles in biological systems and serves many cellular functions. Since biothiols all incorporate thiol, carboxylic and amino groups, discriminative detection of GSH over cysteine (Cys) and homocysteine (Hcy) is still challenging. We herein report a dual-mode nanosensor with both colorimetric and fluorometric readout based on carbon quantum dots and gold nanoparticles for discriminative detection of GSH over Cys/Hcy. The proposed sensing system consists of AuNPs and fluorescent carbon quantum dots (CQDs), where CQDs function as fluorometric reporter, and AuNPs serve a dual function as colorimetric reporter and fluorescence quencher. The mechanism of the nanosensor is based on two distance-dependent phenomenons, color change of AuNPs and FRET. Through controlling the surface properties of as-prepared nanoparticles, the addition of CQDs into AuNPs colloid solution might induce the aggregation of AuNPs and CQDs, leading to AuNPs color changing from red to blue and CQDs fluorescence quench. However, the presence of GSH can protect AuNPs from being aggregated and enlarge the inter-particle distance, which subsequently produces color change and fluorescent signal recovery. The nanosensor described in this report reflects on its simplicity and flexibility, where no further surface functionalization is required for the as-prepared nanoparticles, leading to less laborious and more cost-effective synthesis. The proposed dual-mode nanosensor demonstrated highly selectivity toward GSH, and allows the detection of GSH as low as 50 nM. More importantly, the nanosensor could not only function in aqueous solution for GSH detection with high sensitivity but also exhibit sensitive responses toward GSH in complicated biological environments, demonstrating its potential in bioanalysis and biodection, which might be significant in disease diagnosis in the future. Copyright © 2014 Elsevier B.V. All rights reserved.
Stachelek, Patrycja; Alsimaree, Abdulrahman A; Alnoman, Rua B; Harriman, Anthony; Knight, Julian G
2017-03-16
A small series of boron dipyrromethene (BODIPY) dyes has been synthesized whereby the boron atom is constrained in a five-membered ring formed from either o-dihydroxypyridine or o-aminophenol. In the latter case, the amino group has been converted into the corresponding amide derivative so as to curtail the possibility for light-induced charge transfer from strap to BODIPY. These compounds are weakly emissive in fluid solution but cleavage of the strap, by treatment with a photoacid generator, restores strong fluorescence. Surprisingly, the same compounds remain weakly fluorescent in a rigid glass at 80 K where light-induced charge transfer is most unlikely. In fluid solution, the fluorescence quantum yield increases with increasing temperature due to a thermally activated step but does not correlate with the thermodynamics for intramolecular charge transfer. It is proposed that the strap causes rupture of the potential energy surface for the excited state, creating traps that provide new routes by which the wave packet can return to the ground state. Access to the trap from the excited state is reversible, leading to the delayed emission. Analysis of the temperature dependent emission intensities allows estimation of the kinetic parameters associated with entering and leaving the trap.
Duan, Ying; Zhang, Mengxia; Gao, Jin; Li, Pengmin; Goltsev, Vasilij; Ma, Fengwang
2015-11-01
During the seasonal shift from June to August, air temperatures increase. To explore how apple trees improve their thermotolerance during this shift, we examined the photochemical reaction capacity of apple tree leaves by simultaneous measurement of prompt chlorophyll fluorescence, delayed chlorophyll fluorescence, and modulated 820 nm reflection at varying temperatures. It was found that the reaction centers and antennae of photosystem II (PSII) and photosystem I (PSI), the donor side of PSII, the electron transfer capacity from QA to QB, and the reoxidation capacity of plastoquinol were all sensitive to heat stress, particularly in June. As the season shifted, apple tree leaves improved in thermotolerance. Interestingly, the acclimation to seasonal shift enhanced the thermotolerance of PSII and PSI reaction centers more than that of their antennae, and the activity of PSII more than that of PSI. This may be a strategy for plant adaptation to changes in environmental temperatures. In addition, results from prompt and delayed fluorescence, as well as modulated 820 nm reflection corroborate each other. We suggest that the simultaneous measurement of the three independent signals may provide more information on thermal acclimation mechanisms of photochemical reactions in plant leaves. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Phipps, Jennifer E.; Bec, Julien; Vela, Deborah; Buja, L. Maximilian; Southard, Jeffrey A.; Margulies, Kenneth B.; Marcu, Laura
2017-02-01
FL-IVUS combines intravascular ultrasound with fluorescence lifetime imaging to obtain morphologic and biochemical details from the arterial wall. Ultrasound measurements alone provide morphologic information (plaque burden, remodeling index and presence of calcium). Fluorescence lifetime can determine the presence of a thick fibrous cap, macrophage infiltration, and lipid cores beneath thin fibrous caps. These details are important to assess plaque vulnerability. In this study, we focused on the ability of FL-IVUS to differentiate between early and advanced lipid cores-advanced cores are vulnerable to rupture. We imaged N=12 ex vivo human coronary arteries and performed hematoxylin and eosin, Movat's pentachrome and CD68 immunohistochemistry at 500 micron intervals throughout the length of the vessels. We found only N=1 thin-capped fibroatheroma (TCFA) with an advanced necrotic core and N=7 cases of foam cell infiltration, early lipid cores or deep necrotic cores. IVUS was able to observe the increased plaque burden and calcification of the advanced and deep necrotic cores, but could not identify early lipid cores, foam cell infiltration or discriminate between deep necrotic cores and TCFA. The addition of FLIm to IVUS allowed the TCFA to be discriminated from early lipid accumulation, particularly at 542+/-50 nm (355 nm pulsed excitation): 7.6 +/- 0.5 ns compared to 6.6 +/- 0.4 ns, respectively (P<0.001 by ANOVA analysis). These differences need to be validated in a larger cohort, but exist due to specific lipid content in the necrotic core as well as increased extracellular matrix in early lesions.
Goreham, Renee V; Schroeder, Kathryn L; Holmes, Amy; Bradley, Siobhan J; Nann, Thomas
2018-01-24
The authors describe the synthesis of water-soluble and fluorescent graphene oxide quantum dots via acid exfoliation of graphite nanoparticles. The resultant graphene oxide quantum dots (GoQDs) were then modified with folic acid. Folic acid receptors are overexpressed in cancer cells and hence can bind to functionalized graphene oxide quantum dots. On excitation at 305 nm, the GoQDs display green fluorescence with a peak wavelength at ~520 nm. The modified GoQDs are non-toxic to macrophage cells even after prolonged exposure and high concentrations. Fluorescence lifetime imaging and multiphoton microscopy was used (in combination) to image HeCaT cells exposed to GoQDs, resulting in a superior method for bioimaging. Graphical abstract Schematic representation of graphene oxide quantum dots, folic acid modified graphene oxide quantum dots (red), and the use of fluorescence lifetime to discriminate against green auto-fluorescence of HeCaT cells.
Burger, R; Kurzbuch, D; Gorkin, R; Kijanka, G; Glynn, M; McDonagh, C; Ducrée, J
2015-01-21
In this work we present a centrifugal microfluidic system enabling highly efficient collective trapping and alignment of particles such as microbeads and cells, their multi-colour fluorescent detection and subsequent manipulation by optical tweezers. We demonstrate array-based capture and imaging followed by "cherry-picking" of individual particles, first for fluorescently labelled polystyrene (PS) beads and then for cells. Different cell lines are discriminated based on intracellular as well as surface-based markers.
JPL Fourier transform ultraviolet spectrometer
NASA Technical Reports Server (NTRS)
Cageao, R. P.; Friedl, R. R.; Sander, Stanley P.; Yung, Y. L.
1994-01-01
The Fourier Transform Ultraviolet Spectrometer (FTUVS) is a new high resolution interferometric spectrometer for multiple-species detection in the UV, visible and near-IR. As an OH sensor, measurements can be carried out by remote sensing (limb emission and column absorption), or in-situ sensing (long-path absorption or laser-induced fluorescence). As a high resolution detector in a high repetition rate (greater than 10 kHz) LIF system, OH fluorescence can be discriminated against non-resonant background emission and laser scatter, permitting (0, 0) excitation.
Ultrafast dynamics of photoactive yellow protein via the photoexcitation and emission processes.
Nakamura, Ryosuke; Hamada, Norio; Ichida, Hideki; Tokunaga, Fumio; Kanematsu, Yasuo
2007-01-01
Pump-dump fluorescence spectroscopy was performed for photoactive yellow protein (PYP) at room temperature. The effect of the dump pulse on the population of the potential energy surface of the electronic excited state was examined as depletion in the stationary fluorescence intensity. The dynamic behavior of the population in the electronic excited state was successfully probed in the various combinations of the pump-dump delay, the dump-pulse wavelength, the dump-pulse energy and the observation wavelength. The experimental results were compared with the results obtained by the femtosecond time-resolved fluorescence spectroscopy.
Photon-Counting H33D Detector for Biological Fluorescence Imaging
Michalet, X.; Siegmund, O.H.W.; Vallerga, J.V.; Jelinsky, P.; Millaud, J.E.; Weiss, S.
2010-01-01
We have developed a photon-counting High-temporal and High-spatial resolution, High-throughput 3-Dimensional detector (H33D) for biological imaging of fluorescent samples. The design is based on a 25 mm diameter S20 photocathode followed by a 3-microchannel plate stack, and a cross delay line anode. We describe the bench performance of the H33D detector, as well as preliminary imaging results obtained with fluorescent beads, quantum dots and live cells and discuss applications of future generation detectors for single-molecule imaging and high-throughput study of biomolecular interactions. PMID:20151021
Ferguson, Melanie A; Henshaw, Helen; Clark, Daniel P A; Moore, David R
2014-01-01
The aims of this study were to (i) evaluate the efficacy of phoneme discrimination training for hearing and cognitive abilities of adults aged 50 to 74 years with mild sensorineural hearing loss who were not users of hearing aids, and to (ii) determine participant compliance with a self-administered, computer-delivered, home- and game-based auditory training program. This study was a randomized controlled trial with repeated measures and crossover design. Participants were trained and tested over an 8- to 12-week period. One group (Immediate Training) trained during weeks 1 and 4. A second waitlist group (Delayed Training) did no training during weeks 1 and 4, but then trained during weeks 5 and 8. On-task (phoneme discrimination) and transferable outcome measures (speech perception, cognition, self-report of hearing disability) for both groups were obtained during weeks 0, 4, and 8, and for the Delayed Training group only at week 12. Robust phoneme discrimination learning was found for both groups, with the largest improvements in threshold shown for those with the poorest initial thresholds. Between weeks 1 and 4, the Immediate Training group showed moderate, significant improvements on self-report of hearing disability, divided attention, and working memory, specifically for conditions or situations that were more complex and therefore more challenging. Training did not result in consistent improvements in speech perception in noise. There was no evidence of any test-retest effects between weeks 1 and 4 for the Delayed Training group. Retention of benefit at 4 weeks post-training was shown for phoneme discrimination, divided attention, working memory, and self-report of hearing disability. Improved divided attention and reduced self-reported hearing difficulties were highly correlated. It was observed that phoneme discrimination training benefits some but not all people with mild hearing loss. Evidence presented here, together with that of other studies that used different training stimuli, suggests that auditory training may facilitate cognitive skills that index executive function and the self-perception of hearing difficulty in challenging situations. The development of cognitive skills may be more important than the development of sensory skills for improving communication and speech perception in everyday life. However, improvements were modest. Outcome measures need to be appropriately challenging to be sensitive to the effects of the relatively small amount of training performed.
Liu, Jiancong; Wang, Ning; Yu, Yue; Yan, Yan; Zhang, Hongyue; Li, Jiyang; Yu, Jihong
2017-01-01
Thermally activated delayed fluorescence (TADF) materials are inspiring intensive research in optoelectronic applications. To date, most of the TADF materials are limited to metal-organic complexes and organic molecules with lifetimes of several microseconds/milliseconds that are sensitive to oxygen. We report a facial and general “dots-in-zeolites” strategy to in situ confine carbon dots (CDs) in zeolitic matrices during hydrothermal/solvothermal crystallization to generate high-efficient TADF materials with ultralong lifetimes. The resultant CDs@zeolite composites exhibit high quantum yields up to 52.14% and ultralong lifetimes up to 350 ms at ambient temperature and atmosphere. This intriguing TADF phenomenon is due to the fact that nanoconfined space of zeolites can efficiently stabilize the triplet states of CDs, thus enabling the reverse intersystem crossing process for TADF. Meanwhile, zeolite frameworks can also hinder oxygen quenching to present TADF behavior at air atmosphere. This design concept introduces a new perspective to develop materials with unique TADF performance and various novel delayed fluorescence–based applications. PMID:28560347
Photo-dynamics of roseoflavin and riboflavin in aqueous and organic solvents
NASA Astrophysics Data System (ADS)
Zirak, P.; Penzkofer, A.; Mathes, T.; Hegemann, P.
2009-03-01
Roseoflavin (8-dimethylamino-8-demethyl- D-riboflavin) and riboflavin in aqueous and organic solvents are studied by optical absorption spectroscopy, fluorescence spectroscopy, and fluorescence decay kinetics. Solvent polarity dependent absorption shifts are observed. The fluorescence quantum yields are solvent dependent. For roseoflavin the fluorescence decay shows a bi-exponential dependence (ps to sub-ps time constant, and 100 ps to a few ns time constant). The roseoflavin photo-dynamics is explained in terms of fast intra-molecular charge transfer (diabatic electron transfer) from the dimethylamino electron donor group to the pteridin carbonyl electron acceptor followed by intra-molecular charge recombination. The fast fluorescence component is due to direct locally-excited-state emission, and the slow fluorescence component is due to delayed locally-excited-state emission and charge transfer state emission. The fluorescence decay of riboflavin is mono-exponential. The S 1-state potential energy surface is determined by vibronic relaxation and solvation dynamics due to excited-state dipole moment changes (adiabatic optical electron transfer).
Audiovisual Delay as a Novel Cue to Visual Distance.
Jaekl, Philip; Seidlitz, Jakob; Harris, Laurence R; Tadin, Duje
2015-01-01
For audiovisual sensory events, sound arrives with a delay relative to light that increases with event distance. It is unknown, however, whether humans can use these ubiquitous sound delays as an information source for distance computation. Here, we tested the hypothesis that audiovisual delays can both bias and improve human perceptual distance discrimination, such that visual stimuli paired with auditory delays are perceived as more distant and are thereby an ordinal distance cue. In two experiments, participants judged the relative distance of two repetitively displayed three-dimensional dot clusters, both presented with sounds of varying delays. In the first experiment, dot clusters presented with a sound delay were judged to be more distant than dot clusters paired with equivalent sound leads. In the second experiment, we confirmed that the presence of a sound delay was sufficient to cause stimuli to appear as more distant. Additionally, we found that ecologically congruent pairing of more distant events with a sound delay resulted in an increase in the precision of distance judgments. A control experiment determined that the sound delay duration influencing these distance judgments was not detectable, thereby eliminating decision-level influence. In sum, we present evidence that audiovisual delays can be an ordinal cue to visual distance.
Sivaprakasam, Vasanthi; Lin, Horn-Bond; Huston, Alan L; Eversole, Jay D
2011-03-28
A two-wavelength laser-induced fluorescence (LIF) instrument has been developed and used to characterize individual biological aerosol particles, including biological warfare (BW) agent surrogates. Fluorescence in discrete spectral bands from widely different species, and also from similar species under different growth conditions were measured and compared. The two-wavelength excitation approach was found to increase discrimination among several biological materials, and especially with respect to diesel exhaust particles, a common interferent for LIF BW detection systems. The spectral characteristics of a variety of biological materials and ambient air components have been studied as a function of aerosol particle size and incident fluence.
Shot noise limited detection of OH using the technique of laser induced fluorescence
NASA Technical Reports Server (NTRS)
Bakalyar, D. M.; Davis, L. I., Jr.; Guo, C.; James, J. V.; Kakos, S.; Morris, P. T.; Wang, C. C.
1984-01-01
Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluorescence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the shot-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.
Zhang, Tianyou; Chu, Bei; Li, Wenlian; Su, Zisheng; Peng, Qi Ming; Zhao, Bo; Luo, Yongshi; Jin, Fangming; Yan, Xingwu; Gao, Yuan; Wu, Hairuo; Zhang, Feng; Fan, Di; Wang, Junbo
2014-08-13
We demonstrate highly efficient exciplex delayed-fluorescence organic light-emitting diodes (OLEDs) in which 4,4',4″-tris[3-methylphenyl(phenyl)aminotriphenylamine (m-MTDATA) and 4,7-diphenyl-1,10-phenanthroline (Bphen) were selected as donor and acceptor components, respectively. Our m-MTDATA:Bphen exciplex electroluminescence (EL) mechanism is based on reverse intersystem crossing (RISC) from the triplet to singlet excited states. As a result, an external quantum efficiency (EQE) of 7.79% at 10 mA/cm(2) was observed, which increases by 3.2 and 1.5 times over that reported in Nat. Photonics 2012, 6, 253 and Appl. Phys. Lett. 2012, 101, 023306, respectively. The high EQE would be attributed to a very easy RISC process because the energy difference between the singlet and triplet excited states is almost around zero. The verdict was proven by photoluminescence (PL) rate analysis at different temperatures and time-resolved spectral analysis. Besides, the study of the transient PL process indicates that the presence of an unbalanced charge in exciplex EL devices is responsible for the low EQE and high-efficiency roll-off. When the exciplex devices were placed in a 100 mT magnetic field, the permanently positive magnetoelectroluminescence and magnetoconductivity were observed. The magnetic properties confirm that the efficient exciplex EL only originates from delayed fluorescence via RISC processes but is not related to the triplet-triplet annihilation process.
NASA Astrophysics Data System (ADS)
Simmons, L. J.; Fobbe, D. J.; Berges, J. A.
2016-02-01
Understanding the dynamics of phytoplankton communities has traditionally focused on differences in growth and related processes among taxa. It is now appreciated that differences in mortality could be equally important in contributing to these dynamics. Studying mortality in communities is difficult, especially on relevant time scales, which could be as short as hours to days. Flow cytometry can potentially provide solutions, because it can allow discrimination of different taxa, and when combined with staining, distinguish live and dead cells. We applied flow cytometry and staining to phytoplankton communities in a model system: a small, well-studied, urban pond in southeastern Wisconsin. Using flow cytometry, it was possible to resolve up to six dominant taxa (most <37 µm) and track them through an annual cycle. However, the axes traditionally used, forward scatter (FSC, related to cell size) and red fluorescence (FL3, related to chlorophyll a content) offered poor discrimination. Addition of orange fluorescence (FL2, traditionally related to phycobilipigments) and side scatter (SSC, related to cell surface characteristics) improved separation of taxa, but reproducibility (i.e. the specific position of the taxa on axes) was also more sensitive to environmental variation in the case of the fluorescence parameters. Dead cells could be distinguished by green fluorescence (FL1, using SYTOX Green©), but the stain also affected other fluorescence channels, requiring compensation. Correlations of numbers of dead cells with environmental factors (e.g. temperature, nutrient concentrations, irradiance) were generally poor, suggesting the greater importance of biotic versus abiotic variables in community mortality dynamics. Ongoing work is focusing on the effects of viral pathogens, grazing and allelopathic interactions using experimental manipulations and individual-based modeling.
Belkhodja, R.; Morales, F.; Abadia, A.; Gomez-Aparisi, J.; Abadia, J.
1994-01-01
The application of chlorophyll fluorescence measurements to screening barley (Hordeum vulgare L.) genotypes for salinity tolerance has been investigated. Excised barley leaves were cut under water and incubated with the cut end immersed in water or in a 100-mM NaCl solution, either in the dark or in high light. Changes in rapid fluorescence kinetics occurred in excised barley leaves exposed to the saline solution only when the incubation was carried out in the presence of high light. Fluorescence changes consisted of decreases in the variable to maximum fluorescence ratio and in increases in the relative proportion of variable fluorescence leading to point I in the Kautsky fluorescence induction curve. These relative increases in fluorescence at point I appeared to arise from a delayed plastoquinone reoxidation in the dark, since they disappeared after short, far-red illumination, which is known to excite photosystem I preferentially. We show that a significant correlation existed between some fluorescence parameters, measured after a combined salt and high-light treatment, and other independent measurements of salinity tolerance. These results suggest that chlorophyll fluorescence, and especially the relative fluorescence at point I in the Kautsky fluorescence induction curve, could be used for the screening of barley genotypes for salinity tolerance. PMID:12232117
NASA Technical Reports Server (NTRS)
Middleton, E. M.; McMurtrey, J. E.; Campbell, P. K. Entcheva; Corp, L. A.; Butcher, L. M.; Chappelle, E. W.
2003-01-01
Vegetation productivity is driven by nitrogen (N) availability in soils. Both excessive and low soil N induce physiological changes in plant foliage. In 2001, we examined the use of spectral fluorescence and reflectance measurements to discriminate among plants provided different N fertilizer application rates: 20%, 50%, 100% and 150% of optimal N levels. A suite of optical, fluorescence, and biophysical measurements were collected on leaves from field grown corn (Zea mays L.) and soybean plants (Glycine max L.) grown in pots (greenhouse + ambient sunlight daily). Three types of steady state laser-induced fluorescence measurements were made on adaxial and abaxial surfaces: 1) fluorescence images in four 10 nm bands (blue, green, red, far-red) resulting from broad irradiance excitation; 2) emission spectra (5 nm resolution) produced by excitation at single wavelengths (280,380 or 360, and 532 nm); and 3) excitation spectra (2 nm resolution), with emission wavelengths fixed at wavelengths centered on selected solar Fraunhofer lines (532,607,677 and 745 nm). Two complementary sets of high resolution (less than 2 nm) optical spectra were acquired for both adaxial and abaxial leaf surfaces: 1) optical properties (350-2500 nm) for reflectance, transmittance, and absorptance; and 2) reflectance spectra (500-1000 nm) acquired with and without a short pass filter at 665 nm to determine the fluorescence contribution to apparent reflectance in the 650-750 spectrum, especially at the 685 and 740 nm chlorophyll fluorescence (ChIF) peaks. The strongest relationships between foliar chemistry and optical properties were demonstrated for C/N content and two optical parameters associated with the red edge inflection point. Select optical properties and ChIF parameters were highly correlated for both species. A significant contribution of ChIF to apparent reflectance was observed, averaging 10-25% at 685 nm and 2 - 6% at 740 nm over all N treatments. Discrimination of N treatment groups was possible with specific fluorescence band ratios (e.g., F740/F525 obtained with 380EX). From all measurements assessing fluorescence, higher ChIF and blue/green emissions were measured from the abaxial leaf surfaces; Abaxial surfaces also produced higher reflectances in the 400-800 nm spectrum. Fluorescence information collected in Fraunhofer regions located on the shoulders of ChIF features compared favorably with peak emissions. This supports the potential capability of a future space-born interferometer sensor to capture plant canopy fluorescence.
NASA Astrophysics Data System (ADS)
Luo, Cong; Li, Xiangyang; Huang, Guangtan
2017-08-01
Oil-water discrimination is of great significance in the design and adjustment of development projects in oil fields. For fractured reservoirs, based on anisotropic S-wave splitting information, it becomes possible to effectively solve such problems which are difficult to deal with in traditional longitudinal wave exploration, due to the similar bulk modulus and density of these two fluids. In this paper, by analyzing the anisotropic character of the Chapman model (2009 Geophysics 74 97-103), the velocity and reflection coefficient differences between the fast and slow S-wave caused by fluid substitution have been verified. Then, through a wave field response analysis of the theoretical model, we found that water saturation causes a longer time delay, a larger time delay gradient and a lower amplitude difference between the fast and slow S-wave, while the oil case corresponds to a lower time delay, a lower gradient and a higher amplitude difference. Therefore, a new class attribute has been proposed regarding the amplitude energy of the fast and slow shear wave, used for oil-water distinction. This new attribute, as well as that of the time delay gradient, were both applied to the 3D3C seismic data of carbonate fractured reservoirs in the Luojia area of the Shengli oil field in China. The results show that the predictions of the energy attributes are more consistent with the well information than the time delay gradient attribute, hence demonstrating the great advantages and potential of this new attribute in oil-water recognition.
Fluorescence lifetime spectroscopy for guided therapy of brain tumors.
Butte, Pramod V; Mamelak, Adam N; Nuno, Miriam; Bannykh, Serguei I; Black, Keith L; Marcu, Laura
2011-01-01
This study evaluates the potential of time-resolved laser induced fluorescence spectroscopy (TR-LIFS) as intra-operative tool for the delineation of brain tumor from normal brain. Forty two patients undergoing glioma (WHO grade I-IV) surgery were enrolled in this study. A TR-LIFS prototype apparatus (gated detection, fast digitizer) was used to induce in-vivo fluorescence using a pulsed N2 laser (337 nm excitation, 0.7 ns pulse width) and to record the time-resolved spectrum (360-550 nm range, 10 nm interval). The sites of TR-LIFS measurement were validated by conventional histopathology (H&E staining). Parameters derived from the TR-LIFS data including intensity values and time-resolved intensity decay features (average fluorescence lifetime and Laguerre coefficients values) were used for tissue characterization and classification. 71 areas of tumor and normal brain were analyzed. Several parameters allowed for the differentiation of distinct tissue types. For example, normal cortex (N=35) and normal white matter (N=12) exhibit a longer-lasting fluorescence emission at 390 nm (τ390=2.12±0.10 ns) when compared with 460 nm (τ460=1.16±0.08 ns). High grade glioma (grades III and IV) samples (N=17) demonstrate emission peaks at 460 nm, with large variation at 390 nm while low grade glioma (I and II) samples (N=7) demonstrated a peak fluorescence emission at 460 nm. A linear discriminant algorithm allowed for the classification of low-grade gliomas with 100% sensitivity and 98% specificity. High-grade glioma demonstrated a high degree of heterogeneity thus reducing the discrimination accuracy of these tumors to 47% sensitivity and 94% specificity. Current findings demonstrate that TR-LIFS holds the potential to diagnose brain tumors intra-operatively and to provide a valuable tool for aiding the neurosurgeon-neuropathologist team in to rapidly distinguish between tumor and normal brain during surgery. Copyright © 2010 Elsevier Inc. All rights reserved.
Kenfack, Cyril A; Piémont, Etienne; Ben Gaied, Nouha; Burger, Alain; Mély, Yves
2008-08-14
8-Vinyl-deoxyadenosine (8VA) has been recently introduced as a fluorescent analogue of adenosine that is less perturbing and less quenched than the well-established 2-amino-deoxyribosylpurine (2AP) probe when inserted in oligonucleotides. To further validate 8VA as a fluorescent substitute of A, we compared the ability of 8VA and 2AP in sequences of the type d(CGT TTT XNX TTT TGC) (with N=8VA or 2AP and X=T and C) to discriminate the nature of the opposite base (Y) in duplexes. For both probes, systematic variations in the amplitudes of the short- and long-lived lifetimes of the fluorescence intensity decays as well as in the amplitude of the fast rotational correlation time of the fluorescence anisotropy decays were observed as a function of the nature of Y. From these parameters, we inferred a stability order 8VA-T > 8VA-G > 8VA-A > 8VA-C, similar to the stability order with the native A base, but different from the stability order with 2AP. Using a combination of molecular mechanics and ab initio calculations, we found that the time-resolved parameters of 8VA, but not the 2AP ones, correlate well with the geometry and the strength of the A-Y base-pairing interaction. This may be rationalized by the smaller structural and electronic perturbations induced by the vinyl group in position 8 as compared to the amino group at position 2. As a consequence, substitution of A by 8VA in a base pair was found to only minimally modify the structure and interaction energy of the base pair. Thus, 8VA can be used as a fluorescent substitute of the natural A, to straightforwardly discriminate the nature of the opposite base. This may find interesting applications notably in the elucidation of the mechanisms and dynamics of the DNA mismatch repair system.
Noninvasive detection of diabetes mellitus
NASA Astrophysics Data System (ADS)
Eppstein, Jonathan A.; Bursell, Sven-Erik
1992-05-01
Recent advances in fluorescence spectroscopy of the lens reveal the potential of a non-invasive device and methodology to sensitively measure changes in the lens of the eye associated with diabetes mellitus. The system relies on the detection of the spectrum of fluorescence emitted from a selected volume (approximately 1/10 mm3) of the lens of living human subjects using low power excitation illumination from monochromatic light sources. The sensitivity of this technique is based on the measurement of the fluorescence intensity in a selected region of the fluorescence spectrum and normalization of this fluorescence with respect to attenuation (scattering and absorption) of the incident excitation light. The amplitude of the unshifted Rayleigh line, measured as part of the fluorescence spectrum, is used as a measure of the attenuation of the excitation light in the lens. Using this methodology we have demonstrated that the normalized lens fluorescence provides a more sensitive discrimination between diabetic and non-diabetic lenses than more conventional measurements of fluorescence intensity from the lens. The existing instrumentation will be described as well as the proposed design for a commercial version of the instrument expected to be ready for FDA trials by late 1992. The results from clinical measurements are used to describe a relationship between normalized lens fluorescence and hemoglobin A1c levels in diabetic patients.
Buddhachat, Kittisak; Thitaram, Chatchote; Brown, Janine L.; Klinhom, Sarisa; Bansiddhi, Pakkanut; Penchart, Kitichaya; Ouitavon, Kanita; Sriaksorn, Khanittha; Pa-in, Chalermpol; Kanchanasaka, Budsabong; Somgird, Chaleamchat; Nganvongpanit, Korakot
2016-01-01
We describe the use of handheld X-ray fluorescence, for elephant tusk species identification. Asian (n = 72) and African (n = 85) elephant tusks were scanned and we utilized the species differences in elemental composition to develop a functional model differentiating between species with high precision. Spatially, the majority of measured elements (n = 26) exhibited a homogeneous distribution in cross-section, but a more heterologous pattern in the longitudinal direction. Twenty-one of twenty four elements differed between Asian and African samples. Data were subjected to hierarchical cluster analysis followed by a stepwise discriminant analysis, which identified elements for the functional equation. The best equation consisted of ratios of Si, S, Cl, Ti, Mn, Ag, Sb and W, with Zr as the denominator. Next, Bayesian binary regression model analysis was conducted to predict the probability that a tusk would be of African origin. A cut-off value was established to improve discrimination. This Bayesian hybrid classification model was then validated by scanning an additional 30 Asian and 41 African tusks, which showed high accuracy (94%) and precision (95%) rates. We conclude that handheld XRF is an accurate, non-invasive method to discriminate origin of elephant tusks provides rapid results applicable to use in the field. PMID:27097717
NASA Astrophysics Data System (ADS)
Buddhachat, Kittisak; Thitaram, Chatchote; Brown, Janine L.; Klinhom, Sarisa; Bansiddhi, Pakkanut; Penchart, Kitichaya; Ouitavon, Kanita; Sriaksorn, Khanittha; Pa-in, Chalermpol; Kanchanasaka, Budsabong; Somgird, Chaleamchat; Nganvongpanit, Korakot
2016-04-01
We describe the use of handheld X-ray fluorescence, for elephant tusk species identification. Asian (n = 72) and African (n = 85) elephant tusks were scanned and we utilized the species differences in elemental composition to develop a functional model differentiating between species with high precision. Spatially, the majority of measured elements (n = 26) exhibited a homogeneous distribution in cross-section, but a more heterologous pattern in the longitudinal direction. Twenty-one of twenty four elements differed between Asian and African samples. Data were subjected to hierarchical cluster analysis followed by a stepwise discriminant analysis, which identified elements for the functional equation. The best equation consisted of ratios of Si, S, Cl, Ti, Mn, Ag, Sb and W, with Zr as the denominator. Next, Bayesian binary regression model analysis was conducted to predict the probability that a tusk would be of African origin. A cut-off value was established to improve discrimination. This Bayesian hybrid classification model was then validated by scanning an additional 30 Asian and 41 African tusks, which showed high accuracy (94%) and precision (95%) rates. We conclude that handheld XRF is an accurate, non-invasive method to discriminate origin of elephant tusks provides rapid results applicable to use in the field.
The Phasor Approach to Fluorescence Lifetime Imaging Analysis
Digman, Michelle A.; Caiolfa, Valeria R.; Zamai, Moreno; Gratton, Enrico
2008-01-01
Changing the data representation from the classical time delay histogram to the phasor representation provides a global view of the fluorescence decay at each pixel of an image. In the phasor representation we can easily recognize the presence of different molecular species in a pixel or the occurrence of fluorescence resonance energy transfer. The analysis of the fluorescence lifetime imaging microscopy (FLIM) data in the phasor space is done observing clustering of pixels values in specific regions of the phasor plot rather than by fitting the fluorescence decay using exponentials. The analysis is instantaneous since is not based on calculations or nonlinear fitting. The phasor approach has the potential to simplify the way data are analyzed in FLIM, paving the way for the analysis of large data sets and, in general, making the FLIM technique accessible to the nonexpert in spectroscopy and data analysis. PMID:17981902
Miller, Jeff; Sproesser, Gudrun; Ulrich, Rolf
2008-07-01
In two experiments, we used response signals (RSs) to control processing time and trace out speed--accuracy trade-off(SAT) functions in a difficult perceptual discrimination task. Each experiment compared performance in blocks of trials with constant and, hence, temporally predictable RS lags against performance in blocks with variable, unpredictable RS lags. In both experiments, essentially equivalent SAT functions were observed with constant and variable RS lags. We conclude that there is little effect of advance preparation for a given processing time, suggesting that the discrimination mechanisms underlying SAT functions are driven solely by bottom-up information processing in perceptual discrimination tasks.
Fluorescence and reflectance properties of hemoglobin-pigmented skin disorders
NASA Astrophysics Data System (ADS)
Troyanova, P.; Borisova, E.; Avramov, L.
2007-06-01
There has been growing interest in clinical application of laser-induced autofluorescence (LIAF) and reflectance spectroscopy (RS) to differentiate disease from normal surrounding tissue, including skin pathologies. Pigmented cutaneous lesions diagnosis plays important role in clinical practice, as malignant melanoma, which is characterized with greatest mortality from all skin cancer types, must be carefully discriminated form other colorized pathologies. The goals of this work were investigation of cutaneous hemoglobin-pigmented lesions (heamangioma, angiokeratoma, and fibroma) by the methods of LIAFS and RS. Spectra from healthy skin areas near to the lesion were detected to be used posteriori in analysis. Fluorescence and reflectance of cutaneous hemoglobin-pigmented lesions are used to develop criterion for differentiation from other pigmented pathologies. Origins of the spectral features obtained are discussed and determination of lesion types is achieved using selected spectral features. The spectral results, obtained were used to develop multispectral diagnostic algorithms based on the most prominent spectral features from the fluorescence and reflectance spectra of the lesions investigated. In comparison between normal skin and different cutaneous lesion types and between lesion types themselves sensitivities and specificities higher than 90 % were achieved. These results show a perspective possibility to differentiate hemoglobin-pigmented lesions from other pigmented pathologies using non-invasive and real time discrimination procedure.
Huang, Pengcheng; Li, Sha; Gao, Nan; Wu, Fangying
2015-11-07
Heavy metal pollution can exert severe effects on the environment and human health. Simple, selective, and sensitive detection of heavy metal ions, especially two or more, using a single probe, is thereby of great importance. In this study, we report a new and facile strategy for discriminative detection of Hg(2+) and Cd(2+) with high selectivity and sensitivity via pH-modulated surface chemistry of the glutathione-capped gold NCs (GSH-Au NCs). By simply adjusting pH values of the colloidal solution of the NCs, Hg(2+) could specifically turn off the fluorescence under acidic pH, however, Cd(2+) could exclusively turn on the fluorescence under alkaline pH. This enables the NCs to serve as a dual fluorescent sensor for Hg(2+) and Cd(2+). We demonstrate that these two opposing sensing modes are presumably due to different interaction mechanisms: Hg(2+) induces aggregation by dissociating GSH from the Au surface via robust coordination and, Cd(2+) could passivate the Au surface by forming a Cd-GSH complex with a compact structure. Finally, the present strategy is successfully exploited to separately determine Hg(2+) and Cd(2+) in environmental water samples.
Discrimination of clostridium species using a magnetic bead based hybridization assay
NASA Astrophysics Data System (ADS)
Pahlow, Susanne; Seise, Barbara; Pollok, Sibyll; Seyboldt, Christian; Weber, Karina; Popp, Jürgen
2014-05-01
Clostridium chauvoei is the causative agent of blackleg, which is an endogenous bacterial infection. Mainly cattle and other ruminants are affected. The symptoms of blackleg are very similar to those of malignant edema, an infection caused by Clostridium septicum. [1, 2] Therefore a reliable differentiation of Clostridium chauvoei from other Clostridium species is required. Traditional microbiological detection methods are time consuming and laborious. Additionally, the unique identification is hindered by the overgrowing tendency of swarming Clostridium septicum colonies when both species are present. [1, 3, 4] Thus, there is a crucial need to improve and simplify the specific detection of Clostridium chauvoei and Clostridium septicum. Here we present an easy and fast Clostridium species discrimination method combining magnetic beads and fluorescence spectroscopy. Functionalized magnetic particles exhibit plentiful advantages, like their simple manipulation in combination with a large binding capacity of biomolecules. A specific region of the pathogenic DNA is amplified and labelled with biotin by polymerase chain reaction (PCR). These PCR products were then immobilized on magnetic beads exploiting the strong biotin-streptavidin interaction. The specific detection of different Clostridium species is achieved by using fluorescence dye labeled probe DNA for the hybridization with the immobilized PCR products. Finally, the samples were investigated by fluorescence spectroscopy. [5
NASA Astrophysics Data System (ADS)
Hu, Leqian; Ma, Shuai; Yin, Chunling
2018-03-01
In this work, fluorescence spectroscopy combined with multi-way pattern recognition techniques were developed for determining the geographical origin of kudzu root and detection and quantification of adulterants in kudzu root. Excitation-emission (EEM) spectra were obtained for 150 pure kudzu root samples of different geographical origins and 150 fake kudzu roots with different adulteration proportions by recording emission from 330 to 570 nm with excitation in the range of 320-480 nm, respectively. Multi-way principal components analysis (M-PCA) and multilinear partial least squares discriminant analysis (N-PLS-DA) methods were used to decompose the excitation-emission matrices datasets. 150 pure kudzu root samples could be differentiated exactly from each other according to their geographical origins by M-PCA and N-PLS-DA models. For the adulteration kudzu root samples, N-PLS-DA got better and more reliable classification result comparing with the M-PCA model. The results obtained in this study indicated that EEM spectroscopy coupling with multi-way pattern recognition could be used as an easy, rapid and novel tool to distinguish the geographical origin of kudzu root and detect adulterated kudzu root. Besides, this method was also suitable for determining the geographic origin and detection the adulteration of the other foodstuffs which can produce fluorescence.
ANIMAL MODELS OF COGNITIVE DEVELOPMENT IN NEUROTOXICITY
The thesis of this chapter has been that spatial delayed alternation versus position discrimination learning can serve as a valuable rodent model of cognitive development in neurotoxicology. his model captures dual process conceptualizations of memory in human neuropsychology and...
Short-term memory for responses: the "choose-small" effect.
Fetterman, J G; MacEwen, D
1989-01-01
Pigeons' short-term memory for fixed-ratio requirements was assessed using a delayed symbolic matching-to-sample procedure. Different choices were reinforced after fixed-ratio 10 and fixed-ratio 40 requirements, and delays of 0, 5, or 20 s were sometimes placed between sample ratios and choice. All birds made disproportionate numbers of responses to the small-ratio choice alternative when delays were interposed between ratios and choice, and this bias increased as a function of delay. Preference for the small fixed-ratio alternative was also observed on "no-sample" trials, during which the choice alternatives were presented without a prior sample ratio. This "choose-small" bias is analogous to results obtained by Spetch and Wilkie (1983) with event duration as the discriminative stimulus. The choose-small bias was attenuated when the houselight was turned on during delays, but overall accuracy was not influenced systematically by the houselight manipulation. PMID:2584917
Wakayama, Hideki; Henares, Terence G; Jigawa, Kaede; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki
2013-11-21
A combination of an enzyme-labeled antibody release coating and a novel fluorescent enzyme substrate-copolymerized hydrogel in a microchannel for a single-step, no-wash microfluidic immunoassay is demonstrated. This hydrogel discriminates the free enzyme-conjugated antibody from an antigen-enzyme-conjugated antibody immunocomplex based on the difference in molecular size. A selective and sensitive immunoassay, with 10-1000 ng mL(-1) linear range, is reported.
Simple device for the direct visualization of oral-cavity tissue fluorescence
NASA Astrophysics Data System (ADS)
Lane, Pierre M.; Gilhuly, Terence; Whitehead, Peter D.; Zeng, Haishan; Poh, Catherine; Ng, Samson; Williams, Michelle; Zhang, Lewei; Rosin, Miriam; MacAulay, Calum E.
2006-03-01
Early identification of high-risk disease could greatly reduce both mortality and morbidity due to oral cancer. We describe a simple handheld device that facilitates the direct visualization of oral-cavity fluorescence for the detection of high-risk precancerous and early cancerous lesions. Blue excitation light (400 to 460 nm) is employed to excite green-red fluorescence from fluorophores in the oral tissues. Tissue fluorescence is viewed directly along an optical axis collinear with the axis of excitation to reduce inter- and intraoperator variability. This robust, field-of-view device enables the direct visualization of fluorescence in the context of surrounding normal tissue. Results from a pilot study of 44 patients are presented. Using histology as the gold standard, the device achieves a sensitivity of 98% and specificity of 100% when discriminating normal mucosa from severe dysplasia/carcinoma in situ (CIS) or invasive carcinoma. We envisage this device as a suitable adjunct for oral cancer screening, biopsy guidance, and margin delineation.
Tang, Yunqing; Dai, Luru; Zhang, Xiaoming; Li, Junbai; Hendriks, Johnny; Fan, Xiaoming; Gruteser, Nadine; Meisenberg, Annika; Baumann, Arnd; Katranidis, Alexandros; Gensch, Thomas
2015-01-01
Single molecule localization based super-resolution fluorescence microscopy offers significantly higher spatial resolution than predicted by Abbe’s resolution limit for far field optical microscopy. Such super-resolution images are reconstructed from wide-field or total internal reflection single molecule fluorescence recordings. Discrimination between emission of single fluorescent molecules and background noise fluctuations remains a great challenge in current data analysis. Here we present a real-time, and robust single molecule identification and localization algorithm, SNSMIL (Shot Noise based Single Molecule Identification and Localization). This algorithm is based on the intrinsic nature of noise, i.e., its Poisson or shot noise characteristics and a new identification criterion, QSNSMIL, is defined. SNSMIL improves the identification accuracy of single fluorescent molecules in experimental or simulated datasets with high and inhomogeneous background. The implementation of SNSMIL relies on a graphics processing unit (GPU), making real-time analysis feasible as shown for real experimental and simulated datasets. PMID:26098742
Lü, Gui-Cai; Zhao, Wei-Hong; Wang, Jiang-Tao
2011-01-01
The identification techniques for 10 species of red tide algae often found in the coastal areas of China were developed by combining the three-dimensional fluorescence spectra of fluorescence dissolved organic matter (FDOM) from the cultured red tide algae with principal component analysis. Based on the results of principal component analysis, the first principal component loading spectrum of three-dimensional fluorescence spectrum was chosen as the identification characteristic spectrum for red tide algae, and the phytoplankton fluorescence characteristic spectrum band was established. Then the 10 algae species were tested using Bayesian discriminant analysis with a correct identification rate of more than 92% for Pyrrophyta on the level of species, and that of more than 75% for Bacillariophyta on the level of genus in which the correct identification rates were more than 90% for the phaeodactylum and chaetoceros. The results showed that the identification techniques for 10 species of red tide algae based on the three-dimensional fluorescence spectra of FDOM from the cultured red tide algae and principal component analysis could work well.
NASA Astrophysics Data System (ADS)
Eshelman, E.; Daly, M. G.; Slater, G.; Cloutis, E.
2015-12-01
Raman spectroscopic instruments are highly capable in the search for organics on Mars due to the potential to perform rapid and nondestructive measurements on unprepared samples. Upcoming and future Raman instruments are likely to also incorporate laser-induced fluorescence (LIF) capabilities, which can be added for modest cost and complexity. We demonstrate that it is possible to obtain sub-ns fluorescence lifetime measurements of Mars-relevant organics and minerals if a fast time-gating capability is used with an intensified detector and a short ultraviolet laser pulse. This serves a primary purpose of discriminating mineral from short-lived (less than 10 ns) organic fluorescence, considered a potential biosignature. Additionally, lifetime measurements may assist in determining if more than one fluorescing species is present and provide information concerning the molecular structure as well as the local environment. Fast time-gating is also useful at longer visible or near-IR wavelengths, as this approach increases the sensitivity of the instrument to organic material by removing the majority of the fluorescence background from the Raman signal and reducing the effect of ambient light.
Label-free identification of macrophage phenotype by fluorescence lifetime imaging microscopy
NASA Astrophysics Data System (ADS)
Alfonso-García, Alba; Smith, Tim D.; Datta, Rupsa; Luu, Thuy U.; Gratton, Enrico; Potma, Eric O.; Liu, Wendy F.
2016-04-01
Macrophages adopt a variety of phenotypes that are a reflection of the many functions they perform as part of the immune system. In particular, metabolism is a phenotypic trait that differs between classically activated, proinflammatory macrophages, and alternatively activated, prohealing macrophages. Inflammatory macrophages have a metabolism based on glycolysis while alternatively activated macrophages generally rely on oxidative phosphorylation to generate chemical energy. We employ this shift in metabolism as an endogenous marker to identify the phenotype of individual macrophages via live-cell fluorescence lifetime imaging microscopy (FLIM). We demonstrate that polarized macrophages can be readily discriminated with the aid of a phasor approach to FLIM, which provides a fast and model-free method for analyzing fluorescence lifetime images.
NASA Astrophysics Data System (ADS)
Mahl, Adam; Yemam, Henok; Remedes, Tyler; Stuntz, Jack; Koldemir, Unsal; Sellinger, Alan; Greife, Uwe
2015-10-01
This presentation will review the efforts made by an interdisciplinary development project aimed at cost-effective, thermal neutron sensitive, plastic scintillators as part of the communities efforts towards replacing 3He based detectors. Colorado School of Mines researchers with backgrounds in Physics and Chemistry have worked on the incorporation of 10B in plastics through admixture of various commercial and novel dopants developed at CSM. In addition, new fluorescent dopants have been developed for plastic scintillators in an effort towards better understanding quenching effects and scintillator response to thermal neutrons via pulse shape discrimination methods. Results on transparent samples using fluorescent spectroscopy and gamma/neutron excitation will be presented. Funded via Department of Homeland Security - Domestic Nuclear Detection Office.
Jeon, Sang Kyu; Yook, Kyoung Soo; Lee, Jun Yeob
2016-06-03
Highly efficient exciplex type organic light-emitting diodes were developed using thermally activated delayed fluorescent emitters as donors and acceptors of an exciplex. Blue emitting bis[4-(9,9-dimethyl-9,10-dihydroacridine)phenyl]sulfone (DMAC-DPS) was a donor and 9,9'-(5-(4,6-diphenyl-1,3,5-triazin-2-yl)-1,3-phenylene)bis(9H-carbazole) (DDCzTrz) and 9,9',9″-(5-(4,6-diphenyl-1,3,5-triazin-2-yl)benzene-1,2,3-triyl)tris(9H-carbazole) (TCzTrz) were acceptor materials. The exciplexes of DMAC-DPS:TCzTrz and DMAC-DPS:DDCzTrz resulted in high photoluminescence quantum yield and high quantum efficiency in the green exciplex organic light-emitting diodes. High quantum efficiencies of 13.4% and 15.3% were obtained in the DMAC-DPS:DDCzTrz and DMAC-DPS:TCzTrz exciplex devices.
NASA Astrophysics Data System (ADS)
Jeon, Sang Kyu; Yook, Kyoung Soo; Lee, Jun Yeob
2016-06-01
Highly efficient exciplex type organic light-emitting diodes were developed using thermally activated delayed fluorescent emitters as donors and acceptors of an exciplex. Blue emitting bis[4-(9,9-dimethyl-9,10-dihydroacridine)phenyl]sulfone (DMAC-DPS) was a donor and 9,9‧-(5-(4,6-diphenyl-1,3,5-triazin-2-yl)-1,3-phenylene)bis(9H-carbazole) (DDCzTrz) and 9,9‧,9″-(5-(4,6-diphenyl-1,3,5-triazin-2-yl)benzene-1,2,3-triyl)tris(9H-carbazole) (TCzTrz) were acceptor materials. The exciplexes of DMAC-DPS:TCzTrz and DMAC-DPS:DDCzTrz resulted in high photoluminescence quantum yield and high quantum efficiency in the green exciplex organic light-emitting diodes. High quantum efficiencies of 13.4% and 15.3% were obtained in the DMAC-DPS:DDCzTrz and DMAC-DPS:TCzTrz exciplex devices.
2017-01-01
Thermally activated delayed fluorescence (TADF) materials have shown great potential for highly efficient organic light-emitting diodes (OLEDs). While the current molecular design of TADF materials primarily focuses on combining donor and acceptor units, we present a novel system based on the use of excited-state intramolecular proton transfer (ESIPT) to achieve efficient TADF without relying on the well-established donor–acceptor scheme. In an appropriately designed acridone-based compound with intramolecular hydrogen bonding, ESIPT leads to separation of the highest occupied and lowest unoccupied molecular orbitals, resulting in TADF emission with a photoluminescence quantum yield of nearly 60%. High external electroluminescence quantum efficiencies of up to 14% in OLEDs using this emitter prove that efficient triplet harvesting is possible with ESIPT-based TADF materials. This work will expand and accelerate the development of a wide variety of TADF materials for high performance OLEDs. PMID:28776019
Fourier transform of delayed fluorescence as an indicator of herbicide concentration.
Guo, Ya; Tan, Jinglu
2014-12-21
It is well known that delayed fluorescence (DF) from Photosystem II (PSII) of plant leaves can be potentially used to sense herbicide pollution and evaluate the effect of herbicides on plant leaves. The research of using DF as a measure of herbicides in the literature was mainly conducted in time domain and qualitative correlation was often obtained. Fourier transform is often used to analyze signals. Viewing DF signal in frequency domain through Fourier transform may allow separation of signal components and provide a quantitative method for sensing herbicides. However, there is a lack of an attempt to use Fourier transform of DF as an indicator of herbicide. In this work, the relationship between the Fourier transform of DF and herbicide concentration was theoretically modelled and analyzed, which immediately yielded a quantitative method to measure herbicide concentration in frequency domain. Experiments were performed to validate the developed method. Copyright © 2014 Elsevier Ltd. All rights reserved.
Favril, Sophie; Abma, Eline; Blasi, Francesco; Stock, Emmelie; Devriendt, Nausikaa; Vanderperren, Katrien; de Rooster, Hilde
2018-04-28
One of the major challenges in surgical oncology is the intraoperative discrimination of tumoural versus healthy tissue. Until today, surgeons rely on visual inspection and palpation to define the tumoural margins during surgery and, unfortunately, for various cancer types, the local recurrence rate thus remains unacceptably high. Near-infrared (NIR) fluorescence imaging is an optical imaging technique that can provide real-time preoperative and intraoperative information after administration of a fluorescent probe that emits NIR light once exposed to a NIR light source. This technique is safe, cost-effective and technically easy. Several NIR fluorescent probes are currently studied for their ability to highlight neoplastic cells. In addition, NIR fluorescence imaging holds great promise for sentinel lymph node mapping. The aim of this manuscript is to provide a literature review of the current organic NIR fluorescent probes tested in the light of human oncology and to introduce fluorescence imaging as a valuable asset in veterinary oncology. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
[Rapid identification of hogwash oil by using synchronous fluorescence spectroscopy].
Sun, Yan-Hui; An, Hai-Yang; Jia, Xiao-Li; Wang, Juan
2012-10-01
To identify hogwash oil quickly, the characteristic delta lambda of hogwash oil was analyzed by three dimensional fluorescence spectroscopy with parallel factor analysis, and the model was built up by using synchronous fluorescence spectroscopy with support vector machines (SVM). The results showed that the characteristic delta lambda of hogwash oil was 60 nm. Collecting original spectrum of different samples under the condition of characteristic delta lambda 60 nm, the best model was established while 5 principal components were selected from original spectrum and the radial basis function (RBF) was used as the kernel function, and the optimal penalty factor C and kernel function g were 512 and 0.5 respectively obtained by the grid searching and 6-fold cross validation. The discrimination rate of the model was 100% for both training sets and prediction sets. Thus, it is quick and accurate to apply synchronous fluorescence spectroscopy to identification of hogwash oil.
Protein recognition by a pattern-generating fluorescent molecular probe.
Pode, Zohar; Peri-Naor, Ronny; Georgeson, Joseph M; Ilani, Tal; Kiss, Vladimir; Unger, Tamar; Markus, Barak; Barr, Haim M; Motiei, Leila; Margulies, David
2017-12-01
Fluorescent molecular probes have become valuable tools in protein research; however, the current methods for using these probes are less suitable for analysing specific populations of proteins in their native environment. In this study, we address this gap by developing a unimolecular fluorescent probe that combines the properties of small-molecule-based probes and cross-reactive sensor arrays (the so-called chemical 'noses/tongues'). On the one hand, the probe can detect different proteins by generating unique identification (ID) patterns, akin to cross-reactive arrays. On the other hand, its unimolecular scaffold and selective binding enable this ID-generating probe to identify combinations of specific protein families within complex mixtures and to discriminate among isoforms in living cells, where macroscopic arrays cannot access. The ability to recycle the molecular device and use it to track several binding interactions simultaneously further demonstrates how this approach could expand the fluorescent toolbox currently used to detect and image proteins.
Protein recognition by a pattern-generating fluorescent molecular probe
NASA Astrophysics Data System (ADS)
Pode, Zohar; Peri-Naor, Ronny; Georgeson, Joseph M.; Ilani, Tal; Kiss, Vladimir; Unger, Tamar; Markus, Barak; Barr, Haim M.; Motiei, Leila; Margulies, David
2017-12-01
Fluorescent molecular probes have become valuable tools in protein research; however, the current methods for using these probes are less suitable for analysing specific populations of proteins in their native environment. In this study, we address this gap by developing a unimolecular fluorescent probe that combines the properties of small-molecule-based probes and cross-reactive sensor arrays (the so-called chemical 'noses/tongues'). On the one hand, the probe can detect different proteins by generating unique identification (ID) patterns, akin to cross-reactive arrays. On the other hand, its unimolecular scaffold and selective binding enable this ID-generating probe to identify combinations of specific protein families within complex mixtures and to discriminate among isoforms in living cells, where macroscopic arrays cannot access. The ability to recycle the molecular device and use it to track several binding interactions simultaneously further demonstrates how this approach could expand the fluorescent toolbox currently used to detect and image proteins.
Rana, Subinoy; Elci, S Gokhan; Mout, Rubul; Singla, Arvind K; Yazdani, Mahdieh; Bender, Markus; Bajaj, Avinash; Saha, Krishnendu; Bunz, Uwe H F; Jirik, Frank R; Rotello, Vincent M
2016-04-06
Supramolecular complexes of a family of positively charged conjugated polymers (CPs) and green fluorescent protein (GFP) create a fluorescence resonance energy transfer (FRET)-based ratiometric biosensor array. Selective multivalent interactions of the CPs with mammalian cell surfaces caused differential change in FRET signals, providing a fingerprint signature for each cell type. The resulting fluorescence signatures allowed the identification of 16 different cell types and discrimination between healthy, cancerous, and metastatic cells, with the same genetic background. While the CP-GFP sensor array completely differentiated between the cell types, only partial classification was achieved for the CPs alone, validating the effectiveness of the ratiometric sensor. The utility of the biosensor was further demonstrated in the detection of blinded unknown samples, where 121 of 128 samples were correctly identified. Notably, this selectivity-based sensor stratified diverse cell types in minutes, using only 2000 cells, without requiring specific biomarkers or cell labeling.
Tan, Jin; Li, Rong; Jiang, Zi-Tao
2015-10-01
We report an application of data fusion for chemometric classification of 135 canned samples of Chinese lager beers by manufacturer based on the combination of fluorescence, UV and visible spectroscopies. Right-angle synchronous fluorescence spectra (SFS) at three wavelength difference Δλ=30, 60 and 80 nm and visible spectra in the range 380-700 nm of undiluted beers were recorded. UV spectra in the range 240-400 nm of diluted beers were measured. A classification model was built using principal component analysis (PCA) and linear discriminant analysis (LDA). LDA with cross-validation showed that the data fusion could achieve 78.5-86.7% correct classification (sensitivity), while those rates using individual spectroscopies ranged from 42.2% to 70.4%. The results demonstrated that the fluorescence, UV and visible spectroscopies complemented each other, yielding higher synergic effect. Copyright © 2015 Elsevier Ltd. All rights reserved.
Massaiti Kuboyama Kubota, Thiago; Bebeachibuli Magalhães, Aida; Nery da Silva, Marina; Ribeiro Villas Boas, Paulino; Novelli, Valdenice M; Bastianel, Marinês; Sagawa, Cíntia H D; Cristofani-Yaly, Mariângela; Marcondes Bastos Pereira Milori, Débora
2017-02-01
Although there is substantial diversity among cultivated sweet oranges genotypes with respect to morphological, physiological, and agronomic traits, very little variation at DNA level has been observed. It is possible that this low DNA molecular variability is due to a narrow genetic basis commonly observed in this citrus group. The most different morphological characters observed were originated through mutations, which are maintained by vegetative propagation. Despite all molecular tools available for discrimination between these different accessions, in general, low polymorphism has been observed in all groups of sweet oranges and they may not be identified by molecular markers. In this context, this paper describes the results obtained by using laser-induced fluorescent spectroscopy (LIFS) as a tool to discriminate sweet orange accessions ( Citrus sinensis L. Osbeck) including common, low acidity, pigmented, and navel orange groups, with very little variation at DNA level. The findings showed that LIFS combined with statistical methods is capable to discriminate different accessions. The basic idea is that citrus leaves have multiple fluorophores and concentration depends on their genetics and metabolism. Thus, we consider that the optical properties of citrus leaves may be different, depending on variety. The results have shown that the developed method, for the best classification rate, reaches an average sensitivity and specificity of 95% and 97.5%, respectively. An interesting application of this study is the development of an economically viable tool for early identification in seedling certification, in citrus breeding programs, in cultivar protection, or in germplasm core collection.
Brooker, Holly R; Gyamfi, Irene A; Wieckowska, Agnieszka; Brooks, Nicholas J; Mulvihill, Daniel P; Geeves, Michael A
2018-06-21
Life is dependent upon the ability of a cell to rapidly respond to changes in environment. Small perturbations in local environments change the ability of molecules to interact and hence communicate. Hydrostatic pressure provides a rapid non-invasive, fully-reversible method for modulating affinities between molecules both in vivo and in vitro We have developed a simple fluorescence imaging chamber that allows intracellular protein dynamics and molecular events to be followed at pressures up to 200 bar in living cells. Using yeast we investigate the impact of hydrostatic pressure upon cell growth and cell cycle progression. While 100 bar has no affect upon viability, it induces a delay in chromosome segregation, resulting in the accumulation of long-undivided-bent cells, consistent with disruption of the cytoskeletons. This delay is independent of stress signalling and induces synchronisation of cell-cycle progression. Equivalent affects were observed in Candida albicans , with pressure inducing a reversible cell-cycle delay and hyphal growth. We present a simple novel non-invasive fluorescence microscopy based approach to transiently impact molecular dynamics to visualise, dissect and study signalling pathways and cellular processes in living cells. © 2018. Published by The Company of Biologists Ltd.
Hu, Wenbo; Guo, Lihong; Bai, Lei; Miao, Xiaofei; Ni, Yun; Wang, Qi; Zhao, Hui; Xie, Meng; Li, Lin; Lu, Xiaomei; Huang, Wei; Fan, Quli
2018-05-28
Two-photon fluorescence lifetime imaging (TP-FLIM) not only permits imaging deep inside the tissues with precise spatial manipulation but also circumvents tissue autofluorescence, holding tremendous promise in molecular imaging. However, the serious lack of suitable contrast agents with long fluorescence lifetime and efficient two-photon absorption (TPA) greatly limits the advance of TP-FLIM. This study reports a simple approach to fabricate water-soluble organic semiconducting nanoparticles [thioxanthone (TXO) NPs] with ultralong fluorescence lifetime and efficient TPA for in vivo TP-FLIM. The approach utilizes the aggregation of a specifically selected thermally activated delayed fluorescence (TADF) fluorophore to prolong its fluorescence lifetime. Encapsulating the TADF fluorophore within an amphiphilic copolymer not only maximizes its aggregation but also obtains TXO NPs with efficient TPA. Importantly, as-prepared TXO NPs exhibit a considerably long fluorescence lifetime at a magnitude of 4.2 µs, which is almost 1000 times larger than that of existing organic contrast agents. Moreover, such long fluorescence lifetime is almost oxygen-inert, readily realizing both in vitro and in vivo TP-FLIM. This work may set valuable guidance for designing organic semiconducting materials with ultralong fluorescence lifetimes to fulfill the potential of FLIM. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rangarajan, Suresh; Tram, Hoang Nguyen Bao; Todd, Catherine S.; Thinh, Tran; Hung, Van; Hieu, Pham Thanh; Hanh, Tran My; Chau, Khong Minh; Lam, Nguyen Danh; Hung, Pham Tri; West, Gary; Colby, Donn
2014-01-01
Background We surveyed HIV patients with late-stage disease in southern Vietnam to determine if barriers to access and service quality resulted in late HIV testing and delays from initial diagnosis to entry into HIV care. Methodology 196 adult patients at public HIV clinics with CD4 counts less than 250 cells/mm3 completed a standardized questionnaire. We used multivariate analysis to determine risk factors for delayed entry into care, defined as >3 months time from diagnosis to registration. Results Common reasons for delayed testing were feeling healthy (71%), fear of stigma and discrimination in the community (43%), time conflicts with work or school (31%), did not want to know if infected (30%), and fear of lack of confidentiality (27%). Forty-five percent of participants delayed entry into care with a median CD4 count of 65 cells/mm3. The most common reasons for delayed entry were feeling healthy (51%), fear of stigma and discrimination in the community (41%), time conflicts with work or school (33%), and fear of lack of confidentiality (26%). Independent predictors for delayed entry were feeling healthy (aOR 3.7, 95% CI 1.5–9.1), first positive HIV test at other site (aOR 2.9, CI 1.2–7.1), history of injection drug use (IDU) (aOR 2.9, 95% CI 1.1–7.9), work/school conflicts (aOR 4.3, 95% CI 1.7–10.8), prior registration at another clinic (aOR 77.4, 95% CI 8.6–697), detention or imprisonment (aOR 10.3, 95% CI 1.8–58.2), and perceived distance to clinic (aOR 3.7, 95% CI 1.0–13.7). Conclusion Delayed entry into HIV care in Vietnam is common and poses a significant challenge to preventing AIDS and opportunistic infections, decreasing mortality, and reducing HIV transmission. Improved linkages between testing and care are needed, particularly for patients who feel healthy, as well as incarcerated and drug-using populations who may face structural and social barriers to accessing care. PMID:25330196
Application of Time-Resolved Spectroscopies to the Study of Energetic Materials - 1982
1983-05-24
fluores- cence intensity as a function of UV pulse energy, for individual laser shots. The lower curve shows the UV + probe induced fluorescence... intensity as a function of UV pulse energy, for individual laser shots. The lower curve shows the UV + probe Induced fluorescence, at 1 ns delay...locked Nd:YAG Laser Pulse ", Appl. Phys. Lett 26, 501-503 (1975). 97 43. A. J. Campillo, V. H. Kollman and S. L. Shapiro, " Intensity Dependence of
Plant-based FRET biosensor discriminates enviornmental zinc levels
USDA-ARS?s Scientific Manuscript database
Heavy metal accumulation in the environment poses great risks to flora and fauna. However, monitoring sites prone to accumulation poses scale and economic challenges. In this study, we present and test a method for monitoring these sites using fluorescent resonance energy transfer (FRET) change in r...
Patients’ perceptions of discrimination during hospitalization
Hudelson, Patricia; Kolly, Véronique; Perneger, Thomas
2009-01-01
Abstract Objective To identify sources of perceived discrimination during hospitalization and examine the relationship of perceived discrimination to patient and hospital stay characteristics, and to patient ratings of care. Background Patient experiences of discrimination within the health‐care system are associated with delays in care seeking, non‐adherence to medical advice and poorer health status. Most research to date has focused on race and ethnicity‐based discrimination, and few studies have included hospitalized patients. Methods Questions about patients’ experiences of discrimination were added to a regular patient opinion survey conducted at the Geneva University Hospitals. Participants were 1537 adult residents of Switzerland discharged from the hospital between 15 February and 15 March 2007. Results A total of 171 (11.1%) respondents reported at least one source of discrimination. Most (93, 54.4%) reported a single cause of discrimination. The most frequent causes of discrimination were language, age, nationality and having a disease that is viewed negatively by others. Fifteen percentage of non‐European respondents reported at least one of the following types of discrimination: language, nationality, religion and skin colour. Reporting discrimination from any cause was associated with higher Picker Patient Experience problem scores, and patients who reported discrimination were less likely to describe their care as very good or excellent and less likely to recommend the hospital to others. Conclusions Patient experiences of discrimination during hospitalization are relatively frequent and are associated with lower patient ratings of care. Collection of data on patient experiences of discrimination may contribute to the development of interventions aimed at ensuring respectful, quality care for all patients. PMID:19788555
Komatsu, Ryutaro; Ohsawa, Tatsuya; Sasabe, Hisahiro; Nakao, Kohei; Hayasaka, Yuya; Kido, Junji
2017-02-08
The development of efficient and robust deep-blue emitters is one of the key issues in organic light-emitting devices (OLEDs) for environmentally friendly, large-area displays or general lighting. As a promising technology that realizes 100% conversion from electrons to photons, thermally activated delayed fluorescence (TADF) emitters have attracted considerable attention. However, only a handful of examples of deep-blue TADF emitters have been reported to date, and the emitters generally show large efficiency roll-off at practical luminance over several hundreds to thousands of cd m -2 , most likely because of the long delayed fluorescent lifetime (τ d ). To overcome this problem, we molecularly manipulated the electronic excited state energies of pyrimidine-based TADF emitters to realize deep-blue emission and reduced τ d . We then systematically investigated the relationships among the chemical structure, properties, and device performances. The resultant novel pyrimidine emitters, called Ac-XMHPMs (X = 1, 2, and 3), contain different numbers of bulky methyl substituents at acceptor moieties, increasing the excited singlet (E S ) and triplet state (E T ) energies. Among them, Ac-3MHPM, with a high E T of 2.95 eV, exhibited a high external quantum efficiency (η ext,max ) of 18% and an η ext of 10% at 100 cd m -2 with Commission Internationale de l'Eclairage chromaticity coordinates of (0.16, 0.15). These efficiencies are among the highest values to date for deep-blue TADF OLEDs. Our molecular design strategy provides fundamental guidance to design novel deep-blue TADF emitters.
NASA Astrophysics Data System (ADS)
Sivabalan, Shanmugam; Vedeswari, C. Ponranjini; Jayachandran, Sadaksharam; Koteeswaran, Dornadula; Pravda, Chidambaranathan; Aruna, Prakasa Rao; Ganesan, Singaravelu
2010-01-01
Native fluorescence spectroscopy has shown potential to characterize and diagnose oral malignancy. We aim at extending the native fluorescence spectroscopy technique to characterize normal and oral submucous fibrosis (OSF) patients under pre- and post-treated conditions, and verify whether this method could also be considered in the monitoring of therapeutic prognosis noninvasively. In this study, 28 normal subjects and 28 clinically proven cases of OSF in the age group of 20 to 40 years are diagnosed using native fluorescence spectroscopy. The OSF patients are given dexamethasone sodium phosphate and hyaluronidase twice a week for 6 weeks, and the therapeutic response is monitored using fluorescence spectroscopy. The fluorescence emission spectra of normal and OSF cases of both pre- and post-treated conditions are recorded in the wavelength region of 350 to 600 nm at an excitation wavelength of 330 nm. The statistical significance is verified using discriminant analysis. The oxidation-reduction ratio of the tissue is also calculated using the fluorescence emission intensities of flavin adenine dinucleotide and nicotinamide adinine dinucleotide at 530 and 440 nm, respectively, and they are compared with conventional physical clinical examinations. This study suggests that native fluorescence spectroscopy could also be extended to OSF diagnosis and therapeutic prognosis.
Zhu, Jing; Ding, Yongshun; Liu, Xingti; Wang, Lei; Jiang, Wei
2014-09-15
Highly sensitive and selective detection strategy for single-base mutations is essential for risk assessment of malignancy and disease prognosis. In this work, a fluorescent detection method for single-base mutation was proposed based on high selectivity of toehold-mediated strand displacement reaction (TSDR) and powerful signal amplification capability of isothermal DNA amplification. A discrimination probe was specially designed with a stem-loop structure and an overhanging toehold domain. Hybridization between the toehold domain and the perfect matched target initiated the TSDR along with the unfolding of the discrimination probe. Subsequently, the target sequence acted as a primer to initiate the polymerization and nicking reactions, which released a great abundant of short sequences. Finally, the released strands were annealed with the reporter probe, launching another polymerization and nicking reaction to produce lots of G-quadruplex DNA, which could bind the N-methyl mesoporphyrin IX to yield an enhanced fluorescence response. However, when there was even a single base mismatch in the target DNA, the TSDR was suppressed and so subsequent isothermal DNA amplification and fluorescence response process could not occur. The proposed approach has been successfully implemented for the identification of the single-base mutant sequences in the human KRAS gene with a detection limit of 1.8 pM. Furthermore, a recovery of 90% was obtained when detecting the target sequence in spiked HeLa cells lysate, demonstrating the feasibility of this detection strategy for single-base mutations in biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Flow cytometric detection of micronuclei by combined staining of DNA and membranes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wessels, J.M.; Nuesse, M.
1995-03-01
A new staining method is presented for flow cytometric measurement of micronuclei (MN) in cell cultures and human lymphocytes using membrane-specific fluorescent dyes in addition to DNA staining. Several combinations of fluorescent membrane and DNA dyes were studied for a better discrimination of MN from debris in a suspension of nuclei and micronuclei. For staining of membranes, the lipophilic dyes 2-hydroxyethyl-7,12,17-tris(methoxyethyl)porphycene (HEPn) and 1,6-diphenyl-1,3,5-hexatriene (DPH) were used in combination with ethidium bromide (EB), proflavine (PF), and Hoechst 33258 (HO). Due to their spectral properties, HO or EB combined with HEPn were not as suitable for the discrimination of MN frommore » debris as was HEPn in combination with PF. With HEPn in combination with PF, however, additional noise was found at low fluorescence intensities, probably due to free fluorescent dye molecules in the solution. The optimal simultaneous staining of membranes and DNA was obtained using a combination of DPH and EB. The induction of MN in Chinese hamster and mouse NIH-3T3 cells by UV-B illumination was studied with this new staining technique. UV-B illumination (280-360 nm) induced MN in both cell lines. Chinese hamster cells were found to be more sensitive to these wavelengths. Illumination with wavelengths above 360 nm did not induce MN in either cell line. The results obtained from human lymphocytes using the combination of EB or DPH were comparable to the results obtained with the combination of EB and HO. 23 refs., 7 figs.« less
The fluorescence properties of aerosol larger than 0.8 μm in an urban and a PBA-dominated location
NASA Astrophysics Data System (ADS)
Gabey, A. M.; Stanley, W. R.; Gallagher, M. W.; Kaye, P. H.
2011-01-01
Dual-wavelength Ultraviolet light-induced fluorescence (UV-LIF) measurements were performed on ambient environmental aerosol in Manchester, UK (urban city centre, winter) and Borneo, Malaysia (remote, tropical), which are taken to represent environments with negligible and significant primary biological aerosol (PBA) influences, respectively. Single-particle fluorescence intensity and optical equivalent diameter were measured with a Wide Issue Bioaerosol Sensor, version 3 (WIBS3) in the diameter range 0.8 μm≤DP≤20 μm for 2-3 weeks and filters were analysed using energy dispersive X-ray (EDX) spectroscopy, which revealed mostly non-PBA dominated particle sizes larger than 1 μm in Manchester. The WIBS3 features three fluorescence channels: Fluorescence excited at 280 nm is recorded at 310-400 nm and 400-600 nm and fluorescence excited at 370 nm is detected at 400-600 nm. In Manchester the primary size mode of fluorescent and non-fluorescent material was at 1.2 μm. In Borneo non-fluorescent material peaked at 1.2 μm and fluorescent at 3-4 μm. The fluorescence intensity at 400-600 nm generally increased with DP at both sites, as did the 310-400 nm intensity in Borneo. In Manchester the 310-400 m fluorescence decreased at DP>4 μm, suggesting this channel offers additional discrimination between fluorescent particle types. Finally, the ratio of fluorescence intensity in two pairs of channels was investigated as a function of particle diameter and this varied significantly between the two environments, demonstrating that the fluorescent aerosol in each can in principle be distinguished using a combination of fluorescence and elastic scattering measurements.
Eechaute, Christophe; Vaes, Peter; Duquet, William; Van Gheluwe, Bart
2009-07-01
Studies investigating peroneal muscle reaction times in chronically unstable ankle joints present conflicting results. The degree of reliability and accuracy of these measurements is unknown in patients with chronic ankle instability (CAI). 40 patients with CAI and 30 healthy subjects were tested using a sudden ankle inversion of 50 degrees while standing on a trapdoor device. Sudden ankle inversion measurements were registered using electromyography, accelerometry and electrogoniometry. For reliability testing, intra-class coefficients (ICCs; model 3,1) and standard errors of measurements of the latency time, motor response time and electromechanical delay of the peroneus longus muscle, the time and angular position of onset of decelerations, the mean and maximum inversion speed and the total inversion time were calculated in 15 patients with CAI. To assess between-group differences, t-tests for independent samples (p<.05) were used. ICCs ranged from .20 (angular position of onset of the second deceleration) to .98 (electromechanical delay of the peroneus longus muscle). Significant between-group differences were observed in only 2 of the 12 variables (for the electromechanical delay of the peroneus longus muscle, p=.001; time of onset of the second deceleration, p=.040). The latency time and motor response time of the peroneus longus muscle, the total inversion time and the mean inversion speed demonstrate acceptable reliability in healthy subjects and patients. The latency time and motor response time of the peroneus longus muscle are not delayed in patients with CAI. Ankle inversion measurements are not discriminative for CAI.
Shanmugaraju, Sankarasekaran; Dabadie, Charlyne; Byrne, Kevin; Savyasachi, Aramballi J; Umadevi, Deivasigamani; Schmitt, Wolfgang; Kitchen, Jonathan A; Gunnlaugsson, Thorfinnur
2017-02-01
A V-Shaped 4-amino-1,8-napthalimide derived tetracarboxylic acid linker ( L ; bis-[ N -(1,3-benzenedicarboxylic acid)]-9,18-methano-1,8-naphthalimide-[ b , f ][1,5]diazocine) comprising the Tröger's base (TB) structural motif was rationally designed and synthesised to access a nitrogen-rich fluorescent supramolecular coordination polymer. By adopting the straight forward precipitation method, a new luminescent nanoscale Zn(ii) coordination polymer ( TB-Zn-CP ) was synthesized in quantitative yield using Zn(OAc) 2 ·2H 2 O and tetraacid linker L (1 : 0.5) in DMF at room temperature. The phase-purity of as-synthesised TB-Zn-CP was confirmed by X-ray powder diffraction analysis, infra-red spectroscopy, and elemental analysis. Thermogravimetric analysis suggests that TB-Zn-CP is thermally stable up to 330 °C and the morphological features of TB-Zn-CP was analysed by SEM and AFM techniques. The N 2 adsorption isotherm of thermally activated TB-Zn-CP at 77 K revealed a type-II reversible adsorption isotherm and the calculated Brunauer-Emmett-Teller (BET) surface area was found to be 72 m 2 g -1 . Furthermore, TB-Zn-CP displayed an excellent CO 2 uptake capacity of 76 mg g -1 at 273 K and good adsorption selectivity for CO 2 over N 2 and H 2 . The aqueous suspension of as-synthesized TB-Zn-CP showed strong green fluorescence ( λ max = 520 nm) characteristics due to the internal-charge transfer (ICT) transition and was used as a fluorescent sensor for the discriminative sensing of nitroaromatic explosives. The aqueous suspension of TB-Zn-CP showed the largest quenching responses with high selectivity for phenolic-nitroaromatics (4-NP, 2,4-DNP and PA) even in the concurrent presence of other potentially competing nitroaromatic analytes. The fluorescence titration studies also provide evidence that TB-Zn-CP detects picric acid as low as the parts per billion (26.3 ppb) range. Furthermore, the observed fluorescence quenching responses of TB-Zn-CP towards picric acid were highly reversible. The highly selective fluorescence quenching responses including the reversible detection efficiency make the nanoscale coordination polymer TB-Zn-CP a potential material for the discriminative fluorescent sensing of nitroaromatic explosives.
A Single-Photon Avalanche Diode Array for Fluorescence Lifetime Imaging Microscopy.
Schwartz, David Eric; Charbon, Edoardo; Shepard, Kenneth L
2008-11-21
We describe the design, characterization, and demonstration of a fully integrated single-photon avalanche diode (SPAD) imager for use in time-resolved fluorescence imaging. The imager consists of a 64-by-64 array of active SPAD pixels and an on-chip time-to-digital converter (TDC) based on a delay-locked loop (DLL) and calibrated interpolators. The imager can perform both standard time-correlated single-photon counting (TCSPC) and an alternative gated-window detection useful for avoiding pulse pile-up when measuring bright signal levels. To illustrate the use of the imager, we present measurements of the decay lifetimes of fluorescent dyes of several types with a timing resolution of 350 ps.
A Single-Photon Avalanche Diode Array for Fluorescence Lifetime Imaging Microscopy
Schwartz, David Eric; Charbon, Edoardo; Shepard, Kenneth L.
2013-01-01
We describe the design, characterization, and demonstration of a fully integrated single-photon avalanche diode (SPAD) imager for use in time-resolved fluorescence imaging. The imager consists of a 64-by-64 array of active SPAD pixels and an on-chip time-to-digital converter (TDC) based on a delay-locked loop (DLL) and calibrated interpolators. The imager can perform both standard time-correlated single-photon counting (TCSPC) and an alternative gated-window detection useful for avoiding pulse pile-up when measuring bright signal levels. To illustrate the use of the imager, we present measurements of the decay lifetimes of fluorescent dyes of several types with a timing resolution of 350 ps. PMID:23976789
Predictive Compensator Optimization for Head Tracking Lag in Virtual Environments
NASA Technical Reports Server (NTRS)
Adelstein, Barnard D.; Jung, Jae Y.; Ellis, Stephen R.
2001-01-01
We examined the perceptual impact of plant noise parameterization for Kalman Filter predictive compensation of time delays intrinsic to head tracked virtual environments (VEs). Subjects were tested in their ability to discriminate between the VE system's minimum latency and conditions in which artificially added latency was then predictively compensated back to the system minimum. Two head tracking predictors were parameterized off-line according to cost functions that minimized prediction errors in (1) rotation, and (2) rotation projected into translational displacement with emphasis on higher frequency human operator noise. These predictors were compared with a parameterization obtained from the VE literature for cost function (1). Results from 12 subjects showed that both parameterization type and amount of compensated latency affected discrimination. Analysis of the head motion used in the parameterizations and the subsequent discriminability results suggest that higher frequency predictor artifacts are contributory cues for discriminating the presence of predictive compensation.
Plastic scintillators with efficient neutron/gamma pulse shape discrimination
NASA Astrophysics Data System (ADS)
Zaitseva, Natalia; Rupert, Benjamin L.; PaweŁczak, Iwona; Glenn, Andrew; Martinez, H. Paul; Carman, Leslie; Faust, Michelle; Cherepy, Nerine; Payne, Stephen
2012-03-01
A possibility of manufacturing plastic scintillators with efficient neutron/gamma pulse shape discrimination (PSD) is demonstrated using a system of a polyvinyltoluene (PVT) polymer matrix loaded with a scintillating dye, 2,5-diphenyloxazole (PPO). Similarities and differences of conditions leading to the rise of PSD in liquid and solid organic scintillators are discussed based on the classical model of excited state interaction and delayed light formation. First characterization results are presented to show that PSD in plastic scintillators can be of the similar magnitude or even higher than in standard commercial liquid scintillators.
All-optical phase discrimination using SOA.
Power, Mark J; Webb, Roderick P; Manning, Robert J
2013-11-04
We describe the first experimental demonstration of a novel all-optical phase discrimination technique, which can separate the two orthogonal phase components of a signal onto different frequencies. This method exploits nonlinear mixing in a semiconductor optical amplifier (SOA) to separate a 10.65 Gbaud QPSK signal into two 10.65 Gb/s BPSK signals which are then demodulated using a delay interferometer (DI). Eye diagrams and spectral measurements verify correct operation and a conversion efficiency greater than 9 dB is observed on both output BPSK channels when compared with the input QPSK signal.
Predictive Coding in Area V4: Dynamic Shape Discrimination under Partial Occlusion
Choi, Hannah; Pasupathy, Anitha; Shea-Brown, Eric
2018-01-01
The primate visual system has an exquisite ability to discriminate partially occluded shapes. Recent electrophysiological recordings suggest that response dynamics in intermediate visual cortical area V4, shaped by feedback from prefrontal cortex (PFC), may play a key role. To probe the algorithms that may underlie these findings, we build and test a model of V4 and PFC interactions based on a hierarchical predictive coding framework. We propose that probabilistic inference occurs in two steps. Initially, V4 responses are driven solely by bottom-up sensory input and are thus strongly influenced by the level of occlusion. After a delay, V4 responses combine both feedforward input and feedback signals from the PFC; the latter reflect predictions made by PFC about the visual stimulus underlying V4 activity. We find that this model captures key features of V4 and PFC dynamics observed in experiments. Specifically, PFC responses are strongest for occluded stimuli and delayed responses in V4 are less sensitive to occlusion, supporting our hypothesis that the feedback signals from PFC underlie robust discrimination of occluded shapes. Thus, our study proposes that area V4 and PFC participate in hierarchical inference, with feedback signals encoding top-down predictions about occluded shapes. PMID:29566355
Comparison of three PCR-based assays for SNP genotyping in sugar beet
USDA-ARS?s Scientific Manuscript database
Background: PCR allelic discrimination technologies have broad applications in the detection of single nucleotide polymorphisms (SNPs) in genetics and genomics. The use of fluorescence-tagged probes is the leading method for targeted SNP detection, but assay costs and error rates could be improved t...
Picosecond time-resolved fluorescence spectroscopy of K-590 in the bacteriorhodopsin photocycle.
Atkinson, G H; Blanchard, D; Lemaire, H; Brack, T L; Hayashi, H
1989-01-01
The fluorescence spectrum of a distinct isometric and conformational intermediate formed on the 10(-11) s time scale during the bacteriorhodopsin (BR) photocycle is observed at room temperature using a two laser, pump-probe technique with picosecond time resolution. The BR photocycle is initiated by pulsed (8 ps) excitation at 565 nm, whereas the fluorescence is generated by 4-ps laser pulses at 590 nm. The unstructured fluorescence extends from 650 to 880 nm and appears in the same general spectral region as the fluorescence spectrum assigned to BR-570. The transient fluorescence spectrum can be distinguished from that assigned to BR-570 by a larger emission quantum yield (approximately twice that of BR-570) and by a maximum intensity near 731 nm (shifted 17 nm to higher energy from the maximum of the BR-570 fluorescence spectrum). The fluorescence spectrum of BR-570 only is measured with low energy, picosecond pulsed excitation at 590 nm and is in good agreement with recent data in the literature. The assignment of the transient fluorescence spectrum to the K-590 intermediate is based on its appearance at time delays longer than 40 ps. The K-590 fluorescence spectrum remains unchanged over the entire 40-100-ps interval. The relevance of these fluorescence data with respect to the molecular mechanism used to model the primary processes in the BR photocycle also is discussed. PMID:2713439
The effects of verbal descriptions on performance in lineups and showups.
Wilson, Brent M; Seale-Carlisle, Travis M; Mickes, Laura
2018-01-01
Verbally describing a face has been found to impair subsequent recognition of that face from a photo lineup, a phenomenon known as the verbal overshadowing effect (Schooler & Engstler-Schooler, 1990). Recently, a large direct replication study successfully reproduced that original finding (Alogna et al., 2014). However, in both the original study and the replication studies, memory was tested using only target-present lineups (i.e., lineups containing the previously seen target face), making it possible to compute the correct identification rate (correct ID rate; i.e., the hit rate) but not the false identification rate (false ID rate; i.e., the false alarm rate). Thus, the lower correct ID rate for the verbal condition could reflect either reduced discriminability or a conservative criterion shift relative to the control condition. In four verbal overshadowing experiments reported here, we measured both correct ID rates and false ID rates using photo lineups (Experiments 1 and 2) or single-photo showups (Experiments 3 and 4). The experimental manipulation (verbally describing the face or not) occurred either immediately after encoding (Experiments 1 and 3) or 20-min after encoding (Experiments 2 and 4). In the immediate condition, discriminability did not differ between groups, but in the delayed condition, discriminability was lower in the verbal description group (i.e., a verbal overshadowing effect was observed). A fifth experiment found that the effect of the immediate-versus-delayed manipulation may be attributable to a change in the content of verbal descriptions, with the ratio of diagnostic to generic facial features in the descriptions decreasing as delay increases. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Harvey, Roxann C; Jordan, Chloe J; Tassin, David H; Moody, Kayla R; Dwoskin, Linda P; Kantak, Kathleen M
2013-01-01
Research examining medication effects on set shifting in teens with attention deficit/hyperactivity disorder (ADHD) is lacking. An animal model of ADHD may be useful for exploring this gap. The Spontaneously Hypertensive Rat (SHR) is a commonly used animal model of ADHD. SHR and two comparator strains, Wistar-Kyoto (WKY) and Wistar (WIS), were evaluated during adolescence in a strategy set shifting task under conditions of a 0-sec or 15-sec delay to reinforcer delivery. The task had three phases: initial discrimination, set shift and reversal learning. Under 0-sec delays, SHR performed as well as or better than WKY and WIS. Treatment with 0.3 mg/kg/day atomoxetine had little effect, other than to modestly increase trials to criterion during set shifting in all strains. Under 15-sec delays, SHR had longer lever press reaction times, longer latencies to criterion and more trial omissions than WKY during set shifting and reversal learning. These deficits were not reduced systematically by 1.5 mg/kg/day methylphenidate or 0.3 mg/kg/day atomoxetine. Regarding learning in SHR, methylphenidate improved initial discrimination, whereas atomoxetine improved set shifting but disrupted initial discrimination. During reversal learning, both drugs were ineffective in SHR, and atomoxetine made reaction time and trial omissions greater in WKY. Overall, WIS performance differed from SHR or WKY, depending on phase. Collectively, a genetic model of ADHD in adolescent rats revealed that neither methylphenidate nor atomoxetine mitigated all deficits in SHR during the set shifting task. Thus, methylphenidate or atomoxetine monotherapy may not mitigate all set shift task-related deficits in teens with ADHD. PMID:23376704
Suda, Kayo; Terazima, Masahide; Sato, Hirofumi; Kimura, Yoshifumi
2013-10-17
Excited state intramolecular proton transfer reactions (ESIPT) of 4'-N,N-diethylamino-3-hydroxyflavone (DEAHF) in ionic liquids have been studied by steady-state and time-resolved fluorescence measurements at different excitation wavelengths. Steady-state measurements show the relative yield of the tautomeric form to the normal form of DEAHF decreases as excitation wavelength is increased from 380 to 450 nm. The decrease in yield is significant in ionic liquids that have cations with long alkyl chains. The extent of the decrease is correlated with the number of carbon atoms in the alkyl chains. Time-resolved fluorescence measurements using optical Kerr gate spectroscopy show that ESIPT rate has a strong excitation wavelength dependence. There is a large difference between the spectra at a 200 ps delay from different excitation wavelengths in each ionic liquid. The difference is pronounced in ionic liquids having a long alkyl chain. The equilibrium constant in the electronic excited state obtained at a 200 ps delay and the average reaction rate are also correlated with the alkyl chain length. Considering the results of the steady-state fluorescence and time-resolved measurements, the excitation wavelength dependence of ESIPT is explained by state selective excitation due to the difference of the solvation, and the number of alkyl chain carbon atoms is found to be a good indicator of the effect of inhomogeneity for this reaction.
Pramipexole-induced disruption of behavioral processes fundamental to intertemporal choice.
Johnson, Patrick S; Stein, Jeffrey S; Smits, Rochelle R; Madden, Gregory J
2013-05-01
Evaluating the effects of presession drug administration on intertemporal choice in nonhumans is a useful approach for identifying compounds that promote impulsive behavior in clinical populations, such as those prescribed the dopamine agonist pramipexole (PPX). Based on the results of previous studies, it is unclear whether PPX increases rats' impulsive choice or attenuates aspects of stimulus control. The present study was designed to experimentally isolate behavioral processes fundamental to intertemporal choice and challenge them pharmacologically with PPX administration. In Experiment 1, the hypothesis that PPX increases impulsive choice as a result of enhanced sensitivity to reinforcer delays was tested and disconfirmed. That is, acute PPX diminished delay sensitivity in a manner consistent with disruption of stimulus control whereas repeated PPX had no effect on delay sensitivity. Experiments 2 and 3 elaborated upon this finding by examining the effects of repeated PPX on rats' discrimination of response-reinforcer contingencies and reinforcer amounts, respectively. Accuracy of both discriminations was reduced by PPX. Collectively these results provide no support for past studies that have suggested PPX increases impulsive choice. Instead, PPX impairs stimulus control over choice behavior. The behavioral approach adopted herein could be profitably integrated with genetic and other biobehavioral models to advance our understanding of impulsive behavior associated with drug administration. © Society for the Experimental Analysis of Behavior.
Kaur, Antarpreet; Edland, Steven D; Peavy, Guerry M
2018-01-01
To compare ability of 2 measures of delayed memory (word list, story paragraph) to discriminate Normal Control (NC) subjects from those with amnestic mild cognitive impairment (aMCI). Demographic, neuropsychological, and diagnostic data contributed by 34 Alzheimer's Disease Centers to the National Alzheimer's Coordinating Center characterized 2717 individuals with a diagnosis of either NC (n=2205) or aMCI (n=512). The Montreal Cognitive Assessment-Memory Index Score (MoCA-MIS) assessed delayed word recall, and the Craft Story 21, delayed story recall. Logistic regression and receiver operator characteristic curves controlling for age, sex, and education assessed the ability of each test to differentiate NCs from subjects with aMCI. The MoCA-MIS had significantly better sensitivity and specificity (area under the receiver operator characteristic curve 0.83 vs. 0.80, P=0.004). At sensitivity 80%, the specificity of the MoCA-MIS was 69.1%, compared with 62.8% for the Craft Story. These data suggest that the MoCA-MIS, a recall score from items within the MoCA, is better at discriminating NCs from subjects with aMCI than the Craft Story. Word recall may be an efficient alternative to paragraph recall for diagnostic screening within clinical practice and research settings.
Fluorescence spectroscopy for neoplasms control
NASA Astrophysics Data System (ADS)
Bratchenko, I. A.; Kristoforova, Yu. A.; Myakinin, O. O.; Artemyev, D. N.; Kozlov, S. V.; Moryatov, A. A.; Zakharov, V. P.
2016-04-01
Investigation of malignant skin tumors diagnosis was performed involving two setups for native tissues fluorescence control in visible and near infrared regions. Combined fluorescence analysis for skin malignant melanomas and basal cell carcinomas was performed. Autofluorescence spectra of normal skin and oncological pathologies stimulated by 457 nm and 785 nm lasers were registered for 74 skin tissue samples. Spectra of 10 melanomas and 27 basal cell carcinomas were registered ex vivo. Skin tumors analysis was made on the basis of autofluorescence spectra intensity and curvature for analysis of porphyrins, lipo-pigments, flavins and melanin. Separation of melanomas and basal cell carcinomas was performed on the basis of discriminant analysis. Overall accuracy of basal cell carcinomas and malignant melanomas separation in current study reached 86.5% with 70% sensitivity and 92.6% specificity.
Distyrylbenzene-aldehydes: identification of proteins in water.
Kumpf, Jan; Freudenberg, Jan; Bunz, Uwe H F
2015-05-07
Three different, water soluble, aldehyde-appended distyrylbenzene (DSB) derivatives were prepared. Their interaction with different albumin variants (human, porcine, bovine, lactalbumin, ovalbumin) was investigated (pH 11). All three fluorophores exhibit graded, protein-dependent fluorescence turn-on at slightly differing wavelengths. Linear discriminant analysis (LDA) differentiated all of the investigated albumins and was used to discern commercially available protein shakes. The three DSB derivatives barely react with the constituting amino acids but cysteine. In the proteins significant fluorescence signals are generated, probably due to a combination of imine/N,S-aminal formation and hydrophobic interactions between the DSBs and the proteins.
Plastic scintillator with effective pulse shape discrimination for neutron and gamma detection
Zaitseva, Natalia P.; Carman, M Leslie; Cherepy, Nerine; Glenn, Andrew M.; Hamel, Sebastien; Payne, Stephen A.; Rupert, Benjamin L.
2016-04-12
In one embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 5 wt % or more; wherein the scintillator material exhibits an optical response signature for neutrons that is different than an optical response signature for gamma rays. In another embodiment, a scintillator material includes a polymer matrix; and a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount greater than 10 wt %.
Characterization of porcine eyes based on autofluorescence lifetime imaging
NASA Astrophysics Data System (ADS)
Batista, Ana; Breunig, Hans Georg; Uchugonova, Aisada; Morgado, António Miguel; König, Karsten
2015-03-01
Multiphoton microscopy is a non-invasive imaging technique with ideal characteristics for biological applications. In this study, we propose to characterize three major structures of the porcine eye, the cornea, crystalline lens, and retina using two-photon excitation fluorescence lifetime imaging microscopy (2PE-FLIM). Samples were imaged using a laser-scanning microscope, consisting of a broadband sub-15 femtosecond (fs) near-infrared laser. Signal detection was performed using a 16-channel photomultiplier tube (PMT) detector (PML-16PMT). Therefore, spectral analysis of the fluorescence lifetime data was possible. To ensure a correct spectral analysis of the autofluorescence lifetime data, the spectra of the individual endogenous fluorophores were acquired with the 16-channel PMT and with a spectrometer. All experiments were performed within 12h of the porcine eye enucleation. We were able to image the cornea, crystalline lens, and retina at multiple depths. Discrimination of each structure based on their autofluorescence intensity and lifetimes was possible. Furthermore, discrimination between different layers of the same structure was also possible. To the best of our knowledge, this was the first time that 2PE-FLIM was used for porcine lens imaging and layer discrimination. With this study we further demonstrated the feasibility of 2PE-FLIM to image and differentiate three of the main components of the eye and its potential as an ophthalmologic technique.
Impact of stimulus uncanniness on speeded response
Takahashi, Kohske; Fukuda, Haruaki; Samejima, Kazuyuki; Watanabe, Katsumi; Ueda, Kazuhiro
2015-01-01
In the uncanny valley phenomenon, the causes of the feeling of uncanniness as well as the impact of the uncanniness on behavioral performances still remain open. The present study investigated the behavioral effects of stimulus uncanniness, particularly with respect to speeded response. Pictures of fish were used as visual stimuli. Participants engaged in direction discrimination, spatial cueing, and dot-probe tasks. The results showed that pictures rated as strongly uncanny delayed speeded response in the discrimination of the direction of the fish. In the cueing experiment, where a fish served as a task-irrelevant and unpredictable cue for a peripheral target, we again observed that the detection of a target was slowed when the cue was an uncanny fish. Conversely, the dot-probe task suggested that uncanny fish, unlike threatening stimulus, did not capture visual spatial attention. These results suggested that stimulus uncanniness resulted in the delayed response, and importantly this modulation was not mediated by the feelings of threat. PMID:26052297
Pirsiavash, Ali; Broumandan, Ali; Lachapelle, Gérard
2017-07-05
The performance of Signal Quality Monitoring (SQM) techniques under different multipath scenarios is analyzed. First, SQM variation profiles are investigated as critical requirements in evaluating the theoretical performance of SQM metrics. The sensitivity and effectiveness of SQM approaches for multipath detection and mitigation are then defined and analyzed by comparing SQM profiles and multipath error envelopes for different discriminators. Analytical discussions includes two discriminator strategies, namely narrow and high resolution correlator techniques for BPSK(1), and BOC(1,1) signaling schemes. Data analysis is also carried out for static and kinematic scenarios to validate the SQM profiles and examine SQM performance in actual multipath environments. Results show that although SQM is sensitive to medium and long-delay multipath, its effectiveness in mitigating these ranges of multipath errors varies based on tracking strategy and signaling scheme. For short-delay multipath scenarios, the multipath effect on pseudorange measurements remains mostly undetected due to the low sensitivity of SQM metrics.
Discriminability of Prediction Artifacts in a Time Delayed Virtual Environment
NASA Technical Reports Server (NTRS)
Adelstein, Bernard D.; Jung, Jae Y.; Ellis, Stephen R.
2001-01-01
Overall latency remains an impediment to perceived image stability and consequently to human performance in virtual environment (VE) systems. Predictive compensators have been proposed as a means to mitigate these shortcomings, but they introduce rendering errors because of induced motion overshoot and heightened noise. Discriminability of these compensator artifacts was investigated by a protocol in which head tracked image stability for 35 ms baseline VE system latency was compared against artificially added (16.7 to 100 ms) latency compensated by a previously studied Kalman Filter (K-F) predictor. A control study in which uncompensated 16.7 to 100 ms latencies were compared against the baseline was also performed. Results from 10 subjects in the main study and 8 in the control group indicate that predictive compensation artifacts are less discernible than the disruptions of uncompensated time delay for the shorter but not the longer added latencies. We propose that noise magnification and overshoot are contributory cues to the presence of predictive compensation.
Baxter, Mark G; Bucci, David J; Gorman, Linda K; Wiley, Ronald G; Gallagher, Michela
2013-10-01
Male Long-Evans rats were given injections of either 192 IgG-saporin, an apparently selective toxin for basal forebrain cholinergic neurons (LES), or vehicle (CON) into either the medial septum and vertical limb of the diagonal band (MS/VDB) or bilaterally into the nucleus basalis magnocellularis and substantia innominata (nBM/SI). Place discrimination in the Morris water maze assessed spatial learning, and a trial-unique matching-to-place task in the water maze assessed memory for place information over varying delays. MS/VDB-LES and nBM/SI-LES rats were not impaired relative to CON rats in acquisition of the place discrimination, but were mildly impaired relative to CON rats in performance of the memory task even at the shortest delay, suggesting a nonmnemonic deficit. These results contrast with effects of less selective lesions, which have been taken to support a role for basal forebrain cholinergic neurons in learning and memory. 2013 APA, all rights reserved
Dabadie, Charlyne; Byrne, Kevin; Savyasachi, Aramballi J.; Umadevi, Deivasigamani; Schmitt, Wolfgang; Kitchen, Jonathan A.
2017-01-01
A V-Shaped 4-amino-1,8-napthalimide derived tetracarboxylic acid linker (L; bis-[N-(1,3-benzenedicarboxylic acid)]-9,18-methano-1,8-naphthalimide-[b,f][1,5]diazocine) comprising the Tröger's base (TB) structural motif was rationally designed and synthesised to access a nitrogen-rich fluorescent supramolecular coordination polymer. By adopting the straight forward precipitation method, a new luminescent nanoscale Zn(ii) coordination polymer (TB-Zn-CP) was synthesized in quantitative yield using Zn(OAc)2·2H2O and tetraacid linker L (1 : 0.5) in DMF at room temperature. The phase-purity of as-synthesised TB-Zn-CP was confirmed by X-ray powder diffraction analysis, infra-red spectroscopy, and elemental analysis. Thermogravimetric analysis suggests that TB-Zn-CP is thermally stable up to 330 °C and the morphological features of TB-Zn-CP was analysed by SEM and AFM techniques. The N2 adsorption isotherm of thermally activated TB-Zn-CP at 77 K revealed a type-II reversible adsorption isotherm and the calculated Brunauer–Emmett–Teller (BET) surface area was found to be 72 m2 g–1. Furthermore, TB-Zn-CP displayed an excellent CO2 uptake capacity of 76 mg g–1 at 273 K and good adsorption selectivity for CO2 over N2 and H2. The aqueous suspension of as-synthesized TB-Zn-CP showed strong green fluorescence (λ max = 520 nm) characteristics due to the internal-charge transfer (ICT) transition and was used as a fluorescent sensor for the discriminative sensing of nitroaromatic explosives. The aqueous suspension of TB-Zn-CP showed the largest quenching responses with high selectivity for phenolic-nitroaromatics (4-NP, 2,4-DNP and PA) even in the concurrent presence of other potentially competing nitroaromatic analytes. The fluorescence titration studies also provide evidence that TB-Zn-CP detects picric acid as low as the parts per billion (26.3 ppb) range. Furthermore, the observed fluorescence quenching responses of TB-Zn-CP towards picric acid were highly reversible. The highly selective fluorescence quenching responses including the reversible detection efficiency make the nanoscale coordination polymer TB-Zn-CP a potential material for the discriminative fluorescent sensing of nitroaromatic explosives. PMID:28572910
Towards the implementation of a spectral database for the detection of biological warfare agents
NASA Astrophysics Data System (ADS)
Carestia, M.; Pizzoferrato, R.; Gelfusa, M.; Cenciarelli, O.; D'Amico, F.; Malizia, A.; Scarpellini, D.; Murari, A.; Vega, J.; Gaudio, P.
2014-10-01
The deliberate use of biological warfare agents (BWA) and other pathogens can jeopardize the safety of population, fauna and flora, and represents a concrete concern from the military and civil perspective. At present, the only commercially available tools for fast warning of a biological attack can perform point detection and require active or passive sampling collection. The development of a stand-off detection system would be extremely valuable to minimize the risk and the possible consequences of the release of biological aerosols in the atmosphere. Biological samples can be analyzed by means of several optical techniques, covering a broad region of the electromagnetic spectrum. Strong evidence proved that the informative content of fluorescence spectra could provide good preliminary discrimination among those agents and it can also be obtained through stand-off measurements. Such a system necessitates a database and a mathematical method for the discrimination of the spectral signatures. In this work, we collected fluorescence emission spectra of the main BWA simulants, to implement a spectral signature database and apply the Universal Multi Event Locator (UMEL) statistical method. Our preliminary analysis, conducted in laboratory conditions with a standard UV lamp source, considers the main experimental setups influencing the fluorescence signature of some of the most commonly used BWA simulants. Our work represents a first step towards the implementation of a spectral database and a laser-based biological stand-off detection and identification technique.
Potential of fluorescence spectroscopy for the characterisation of maple syrup flavours.
Panneton, Bernard; Clément, Alain; Lagacé, Luc
2013-10-01
Maple syrup has high maket value. It is produced in North East America from the heat-evaporated sap of Acer saccharum Marshall. For marketing purposes, there is interest in defining its flavour profile in a consistent and repeatable manner. An experiment was undertaken to explore the potential of autofluorescence of maple syrup induced at 275 and 360 nm to characterise flavours. A mixed data factor analysis revealed two independent groups of variables. One represents early season woody and late season empyreumatic flavours. The other is related to off-flavour, confectionery and maple flavours. Maple and confectionery flavours are subtle, difficult to distinguish and opposed to off-flavour. There were clear relationships among the two groups and fluorescence profiles. For each of the five basic flavours, discriminant models based on partial least squares regressions were developed. For each sample of syrup, flavours combined to form flavour profiles, and the results from the five discriminant models were aggregated to reproduce these profiles. For excitation at 275 nm, the woody/off-flavour and confectionery/empyreumatic/maple flavour profiles were classified correctly 86 and 78% of the time (cross-validation) respectively. Induced autofluorescence spectra were shown to contain information related to maple syrup flavours. This fluorescence-flavour relationship is not considered quantitative yet, and further research avenues are proposed. © 2013 Society of Chemical Industry.
Excitation-scanning hyperspectral imaging as a means to discriminate various tissues types
NASA Astrophysics Data System (ADS)
Deal, Joshua; Favreau, Peter F.; Lopez, Carmen; Lall, Malvika; Weber, David S.; Rich, Thomas C.; Leavesley, Silas J.
2017-02-01
Little is currently known about the fluorescence excitation spectra of disparate tissues and how these spectra change with pathological state. Current imaging diagnostic techniques have limited capacity to investigate fluorescence excitation spectral characteristics. This study utilized excitation-scanning hyperspectral imaging to perform a comprehensive assessment of fluorescence spectral signatures of various tissues. Immediately following tissue harvest, a custom inverted microscope (TE-2000, Nikon Instruments) with Xe arc lamp and thin film tunable filter array (VersaChrome, Semrock, Inc.) were used to acquire hyperspectral image data from each sample. Scans utilized excitation wavelengths from 340 nm to 550 nm in 5 nm increments. Hyperspectral images were analyzed with custom Matlab scripts including linear spectral unmixing (LSU), principal component analysis (PCA), and Gaussian mixture modeling (GMM). Spectra were examined for potential characteristic features such as consistent intensity peaks at specific wavelengths or intensity ratios among significant wavelengths. The resultant spectral features were conserved among tissues of similar molecular composition. Additionally, excitation spectra appear to be a mixture of pure endmembers with commonalities across tissues of varied molecular composition, potentially identifiable through GMM. These results suggest the presence of common autofluorescent molecules in most tissues and that excitationscanning hyperspectral imaging may serve as an approach for characterizing tissue composition as well as pathologic state. Future work will test the feasibility of excitation-scanning hyperspectral imaging as a contrast mode for discriminating normal and pathological tissues.
Motion corrected photoacoustic difference imaging of fluorescent contrast agents
NASA Astrophysics Data System (ADS)
Märk, Julia; Wagener, Asja; Pönick, Sarah; Grötzinger, Carsten; Zhang, Edward; Laufer, Jan
2016-03-01
In fluorophores, such as exogenous dyes and genetically expressed proteins, the excited state lifetime can be modulated using pump-probe excitation at wavelengths corresponding to the absorption and fluorescence spectra. Simultaneous pump-probe pulses induce stimulated emission (SE) which, in turn, modulates the thermalized energy, and hence the photoacoustic (PA) signal amplitude. For time-delayed pulses, by contrast, SE is suppressed. Since this is not observed in endogenous chromophores, the location of the fluorophore can be determined by subtracting images acquired using simultaneous and time-delayed pump-probe excitation. This simple experimental approach exploits a fluorophorespecific contrast mechanism, and has the potential to enable deep-tissue molecular imaging at fluences below the MPE. In this study, some of the challenges to its in vivo implementation are addressed. First, the PA signal amplitude generated in fluorophores in vivo is often much smaller than that in blood. Second, tissue motion can give rise to artifacts that correspond to endogenous chromophores in the difference image. This would not allow the unambiguous detection of fluorophores. A method to suppress motion artifacts based on fast switching between simultaneous and time-delayed pump-probe excitation was developed. This enables the acquisition of PA signals using the two excitation modes with minimal time delay (20 ms), thus minimizing the effects of tissue motion. The feasibility of this method is demonstrated by visualizing a fluorophore (Atto680) in tissue phantoms, which were moved during the image acquisition to mimic tissue motion.
NASA Astrophysics Data System (ADS)
Xu, Zhang; Reilley, Michael; Li, Run; Xu, Min
2017-06-01
We report chemometric wide-field fluorescence microscopy for imaging the spatial distribution and concentration of endogenous fluorophores in thin tissue sections. Nonnegative factorization aided by spatial diversity is used to learn both the spectral signature and the spatial distribution of endogenous fluorophores from microscopic fluorescence color images obtained under broadband excitation and detection. The absolute concentration map of individual fluorophores is derived by comparing the fluorescence from "pure" fluorophores under the identical imaging condition following the identification of the fluorescence species by its spectral signature. This method is then demonstrated by characterizing the concentration map of endogenous fluorophores (including tryptophan, elastin, nicotinamide adenine dinucleotide, and flavin adenine dinucleotide) for lung tissue specimens. The absolute concentrations of these fluorophores are all found to decrease significantly from normal, perilesional, to cancerous (squamous cell carcinoma) tissue. Discriminating tissue types using the absolute fluorophore concentration is found to be significantly more accurate than that achievable with the relative fluorescence strength. Quantification of fluorophores in terms of the absolute concentration map is also advantageous in eliminating the uncertainties due to system responses or measurement details, yielding more biologically relevant data, and simplifying the assessment of competing imaging approaches.
Bay, Christiane; Togsverd-Bo, Katrine; Lerche, Catharina M; Haedersdal, Merete
2016-01-01
Photodynamic therapy (PDT) delays ultraviolet (UV) radiation-induced squamous cell carcinomas (SCCs) in hairless mice. Efficacy may be enhanced by combining PDT with antineoplastic or pro-differentiating agents. We investigated if pretreatment with 5-fluorouracil (5FU), imiquimod (IMIQ) or calcipotriol (CAL) before PDT further delays tumor onset. Hairless mice (n=224) were exposed 3 times weekly to 3 standard erythema doses (SED) of UV radiation. Methyl-aminolevulinate (MAL)-PDT sessions were given on days 45 and 90 before SCC development. Three applications of topical 5FU, IMIQ or CAL were given before each PDT session. Fluorescence photography quantified protoporphyrin IX (PpIX) formation. PDT delayed UV-induced SCC development by 59 days (212 days UV-MAL-PDT vs. 153 days UV-control, P<0.001). Pretreatment with 5FU, IMIQ or CAL before PDT did not further delay SCC onset compared to PDT alone (207 days UV-5FU-MAL-PDT, 215 days UV-IMIQ-MAL-PDT, 206 days UV-CAL-MAL-PDT vs. 212 days UV-MAL-PDT, P=ns). PpIX fluorescence intensified by 5FU-pretreatment (median 21,392 au UV-5FU-MAL-PDT, P=0.011), decreased after IMIQ-pretreatment (12,452 au UV-IMIQ-MAL-PDT, P<0.001), and was unaffected by CAL-pretreatment (19,567 au UV-CAL-MAL-PDT, P=ns) compared to MAL alone (18,083 au UV-MAL-PDT). Short-term three-day pretreatment with 5FU, IMIQ and CAL before PDT does not further delay tumor onset in UV-exposed hairless mice. Copyright © 2015 Elsevier B.V. All rights reserved.
Lee, Dong Hyun; Choi, Sun Young; Seo, Jeong-Min; Choi, Jae-Hyuk; Cho, Young-Rak; Park, Kyungil; Kim, Moo Hyun; Kim, Young-Dae
2015-01-01
Background and Objectives Previous studies have evaluated atrial electromechanical delays (AEMDs) with a number of different definitions to discriminate patients with paroxysmal atrial fibrillation (PAF) from controls without PAF. However, their discriminative values for PAF have not previously been directly compared. Subjects and Methods A total of 65 PAF patients and 130 control subjects matched for age, sex, history of hypertension, and diabetes mellitus were selected. The AEMDi and AEMDp were defined as the time intervals from the initiation of the P wave on the surface electrocardiogram to the initiation and peak of the late diastolic transmitral inflow on pulsed wave Doppler images, respectively. The AEMDim and AEMDpm were defined as the time intervals from the initiation of the P wave on the surface electrocardiogram to the initiation and peak of the late diastolic lateral mitral annular motion on tissue Doppler images, respectively. Results There were no significant differences in the clinical characteristics between the two groups. All 4 AEMDs were consistently longer in the PAF group, and proven effective to differentiate the PAF patients from the controls. The AEMDi measurement had a larger area under the curve (AUC) than the other AEMDs, left atrial volume index, and P wave amplitude. However, the AEMDp, AEMDim, and AEMDpm measurements had AUCs similar to those of the left atrial volume index and P wave amplitude. Conclusion The findings suggest that the AEMDi is better than the other AEMDs for the discrimination of PAF patients from the controls. PMID:26617650
Validation of a time-resolved fluorescence spectroscopy apparatus in a rabbit atherosclerosis model
NASA Astrophysics Data System (ADS)
Fang, Qiyin; Jo, Javier A.; Papaioannou, Thanassis; Dorafshar, Amir; Reil, Todd; Qiao, Jian-Hua; Fishbein, Michael C.; Freischlag, Julie A.; Marcu, Laura
2004-07-01
Time-resolved laser-induced fluorescence spectroscopy (tr-LIFS) has been studied as a potential tool for in vivo diagnosis of atherosclerotic lesions. This study is to evaluate the potential of a compact fiber-optics based tr-LIFS instrument developed in our laboratory for in vivo analysis of atherosclerotic plaque composition. Time-resolved fluorescence spectroscopy studies were performed in vivo on fifteen New Zealand White rabbits (atherosclerotic: N=8, control: N=7). Time-resolved fluorescence spectra were acquired (range: 360-600 nm, increment: 5 nm, total acquisition time: 65 s) from normal aorta wall and lesions in the abdominal aorta. Data were analyzed in terms of fluorescence emission spectra and wavelength specific lifetimes. Following trichrome staining, tissue specimens were analyzed histopathologically in terms of intima/media thickness and biochemical composition (collagen, elastin, foam cells, and etc). Based on intimal thickness, the lesions were divided into thin and thick lesions. Each group was further separated into two categories: collagen rich lesions and foam cell rich lesions based on their biochemical composition. The obtained spectral and time domain fluorescence signatures were subsequently correlated to the histopathological findings. The results have shown that time-domain fluorescence spectral features can be used in vivo to separate atherosclerotic lesions from normal aorta wall as well discrimination within certain types of lesions.
QSPR studies on the photoinduced-fluorescence behaviour of pharmaceuticals and pesticides.
López-Malo, D; Bueso-Bordils, J I; Duart, M J; Alemán-López, P A; Martín-Algarra, R V; Antón-Fos, G M; Lahuerta-Zamora, L; Martínez-Calatayud, J
2017-07-01
Fluorimetric analysis is still a growing line of research in the determination of a wide range of organic compounds, including pharmaceuticals and pesticides, which makes necessary the development of new strategies aimed at improving the performance of fluorescence determinations as well as the sensitivity and, especially, the selectivity of the newly developed analytical methods. In this paper are presented applications of a useful and growing tool suitable for fostering and improving research in the analytical field. Experimental screening, molecular connectivity and discriminant analysis are applied to organic compounds to predict their fluorescent behaviour after their photodegradation by UV irradiation in a continuous flow manifold (multicommutation flow assembly). The screening was based on online fluorimetric measurement and comprised pre-selected compounds with different molecular structures (pharmaceuticals and some pesticides with known 'native' fluorescent behaviour) to study their changes in fluorescent behaviour after UV irradiation. Theoretical predictions agree with the results from the experimental screening and could be used to develop selective analytical methods, as well as helping to reduce the need for expensive, time-consuming and trial-and-error screening procedures.
NASA Astrophysics Data System (ADS)
Anderson, Benjamin; Buah-Bassuah, Paul K.; Tetteh, Jonathan P.
2004-07-01
The use of violet laser-induced chlorophyll fluorescence (LICF) emission spectra to monitor the growth of five varieties of cowpea in the University of Cape Coast Botanical Garden is presented. Radiation from a continuous-wave violet laser diode emitting at 396 nm through a fibre is closely incident on in vivo leaves of cowpea to excite chlorophyll fluorescence, which is detected by an integrated spectrometer with CCD readout. The chlorophyll fluorescence spectra with peaks at 683 and 731 nm were used for growth monitoring of the cowpea plants over three weeks and analysed using Gaussian spectral functions with curve fitted parameters to determine the peak positions, area under the spectral curve and the intensity ratio F683/F731. The variation in the intensity ratio of the chlorophyll bands showed sensitive changes indicating the photosynthetic activity of the cowpea varieties. A discussion of the fluorescence result as compared to conventional assessment is presented with regard to discrimination between the cowpea varieties in terms of crop yield performance.
Determination of the botanical origin of honey by front-face synchronous fluorescence spectroscopy.
Lenhardt, Lea; Zeković, Ivana; Dramićanin, Tatjana; Dramićanin, Miroslav D; Bro, Rasmus
2014-01-01
Front-face synchronous fluorescence spectroscopy combined with chemometrics is used to classify honey samples according to their botanical origin. Synchronous fluorescence spectra of three monofloral (linden, sunflower, and acacia), polyfloral (meadow mix), and fake (fake acacia and linden) honey types (109 samples) were collected in an excitation range of 240-500 nm for synchronous wavelength intervals of 30-300 nm. Chemometric analysis of the gathered data included principal component analysis and partial least squares discriminant analysis. Mean cross-validated classification errors of 0.2 and 4.8% were found for a model that accounts only for monofloral samples and for a model that includes both the monofloral and polyfloral groups, respectively. The results demonstrate that single synchronous fluorescence spectra of different honeys differ significantly because of their distinct physical and chemical characteristics and provide sufficient data for the clear differentiation among honey groups. The spectra of fake honey samples showed pronounced differences from those of genuine honey, and these samples are easily recognized on the basis of their synchronous fluorescence spectra. The study demonstrated that this method is a valuable and promising technique for honey authentication.
Pan, Sha-sha; Huang, Fu-rong; Xiao, Chi; Xian, Rui-yi; Ma, Zhi-guo
2015-10-01
To explore rapid reliable methods for detection of Epicarpium citri grandis (ECG), the experiment using Fourier Transform Attenuated Total Reflection Infrared Spectroscopy (FTIR/ATR) and Fluorescence Spectrum Imaging Technology combined with Multilayer Perceptron (MLP) Neural Network pattern recognition, for the identification of ECG, and the two methods are compared. Infrared spectra and fluorescence spectral images of 118 samples, 81 ECG and 37 other kinds of ECG, are collected. According to the differences in tspectrum, the spectra data in the 550-1 800 cm(-1) wavenumber range and 400-720 nm wavelength are regarded as the study objects of discriminant analysis. Then principal component analysis (PCA) is applied to reduce the dimension of spectroscopic data of ECG and MLP Neural Network is used in combination to classify them. During the experiment were compared the effects of different methods of data preprocessing on the model: multiplicative scatter correction (MSC), standard normal variable correction (SNV), first-order derivative(FD), second-order derivative(SD) and Savitzky-Golay (SG). The results showed that: after the infrared spectra data via the Savitzky-Golay (SG) pretreatment through the MLP Neural Network with the hidden layer function as sigmoid, we can get the best discrimination of ECG, the correct percent of training set and testing set are both 100%. Using fluorescence spectral imaging technology, corrected by the multiple scattering (MSC) results in the pretreatment is the most ideal. After data preprocessing, the three layers of the MLP Neural Network of the hidden layer function as sigmoid function can get 100% correct percent of training set and 96.7% correct percent of testing set. It was shown that the FTIR/ATR and fluorescent spectral imaging technology combined with MLP Neural Network can be used for the identification study of ECG and has the advantages of rapid, reliable effect.
Fiber-optic delay-line stabilization of heterodyne optical signal generator and method using same
NASA Technical Reports Server (NTRS)
Logan, Ronald T. (Inventor)
1997-01-01
The present invention is a laser heterodyne frequency generator system with a stabilizer for use in the microwave and millimeter-wave frequency ranges utilizing a photonic mixer as a photonic phase detector in a stable optical fiber delay-line. Phase and frequency fluctuations of the heterodyne laser signal generators are stabilized at microwave and millimeter wave frequencies by a delay line system operating as a frequency discriminator. The present invention is free from amplifier and mixer 1/.function. noise at microwave and millimeter-wave frequencies that typically limit phase noise performance in electronic cavity stabilized electronic oscillators. Thus, 1/.function. noise due to conventional mixers is eliminated and stable optical heterodyne generation of electrical signals is achieved.
Cell-Based Odorant Sensor Array for Odor Discrimination Based on Insect Odorant Receptors.
Termtanasombat, Maneerat; Mitsuno, Hidefumi; Misawa, Nobuo; Yamahira, Shinya; Sakurai, Takeshi; Yamaguchi, Satoshi; Nagamune, Teruyuki; Kanzaki, Ryohei
2016-07-01
The olfactory system of living organisms can accurately discriminate numerous odors by recognizing the pattern of activation of several odorant receptors (ORs). Thus, development of an odorant sensor array based on multiple ORs presents the possibility of mimicking biological odor discrimination mechanisms. Recently, we developed novel odorant sensor elements with high sensitivity and selectivity based on insect OR-expressing Sf21 cells that respond to target odorants by displaying increased fluorescence intensity. Here we introduce the development of an odorant sensor array composed of several Sf21 cell lines expressing different ORs. In this study, an array pattern of four cell lines expressing Or13a, Or56a, BmOR1, and BmOR3 was successfully created using a patterned polydimethylsiloxane film template and cell-immobilizing reagents, termed biocompatible anchor for membrane (BAM). We demonstrated that BAM could create a clear pattern of Sf21 sensor cells without impacting their odorant-sensing performance. Our sensor array showed odorant-specific response patterns toward both odorant mixtures and single odorant stimuli, allowing us to visualize the presence of 1-octen-3-ol, geosmin, bombykol, and bombykal as an increased fluorescence intensity in the region of Or13a, Or56a, BmOR1, and BmOR3 cell lines, respectively. Therefore, we successfully developed a new methodology for creating a cell-based odorant sensor array that enables us to discriminate multiple target odorants. Our method might be expanded into the development of an odorant sensor capable of detecting a large range of environmental odorants that might become a promising tool used in various applications including the study of insect semiochemicals and food contamination.
Fernández de la Ossa, Ma Ángeles; Ortega-Ojeda, Fernando; García-Ruiz, Carmen
2013-08-09
This work is focused on a novel procedure to discriminate nitrocellulose-based samples with non-explosive and explosive properties. The nitrocellulose study has been scarcely approached in the literature due to its special polymeric properties such as its high molar mass and complex chemical and structural characteristics. These properties require the nitrocellulose analysis to be performed by using a few organic solvents and in consequence, they limit the number of adequate analytical techniques for its study. In terms of identification of pre-blast explosives, mass spectrometry is one of the most preferred technique because it allows to obtain structural information. However, it has never been used to analyze polymeric nitrocellulose. In this study, the differentiation of non-explosive and explosive samples through nitrocellulose fingerprints obtained by capillary electrophoresis was investigated. A batch of 30 different smokeless gunpowders and 23 different everyday products were pulverized, derivatized with a fluorescent agent and analyzed by capillary electrophoresis with laser-induced fluorescence detection. Since this methodology is specific to d-glucopyranose derivatives (cellulosic and related compounds), and paper samples could be easily found in explosion scenes, 11 different paper samples were also included in the study as potential interference samples. In order to discriminate among samples, multivariate analysis (principal component analysis and soft independent modeling of class analogy) was applied to the obtained electrophoretic profiles. To the best of our knowledge, this represents the first study that achieve a successful discrimination between non-explosive and explosive nitrocellulose-based samples, as well as potential cellulose interference samples, and posterior classification of unknown samples into their corresponding groups using CE-LIF and chemometric tools. Copyright © 2013 Elsevier B.V. All rights reserved.
Xiao, Sai Jin; Hu, Ping Ping; Chen, Li Qiang; Zhen, Shu Jun; Peng, Li; Li, Yuan Fang; Huang, Cheng Zhi
2013-01-01
Molecular logic gates, which have attracted increasing research interest and are crucial for the development of molecular-scale computers, simplify the results of measurements and detections, leaving the diagnosis of disease either "yes" or "no". Prion diseases are a group of fatal neurodegenerative disorders that happen in human and animals. The main problem with a diagnosis of prion diseases is how to sensitively and selectively discriminate and detection of the minute amount of PrP(Res) in biological samples. Our previous work had demonstrated that dual-aptamer strategy could achieve highly sensitive and selective discrimination and detection of prion protein (cellular prion protein, PrP(C), and the diseases associated isoform, PrP(Res)) in serum and brain. Inspired by the advantages of molecular logic gate, we further conceived a new concept for dual-aptamer logic gate that responds to two chemical input signals (PrP(C) or PrP(Res) and Gdn-HCl) and generates a change in fluorescence intensity as the output signal. It was found that PrP(Res) performs the "OR" logic operation while PrP(C) performs "XOR" logic operation when they get through the gate consisted of aptamer modified reusable magnetic microparticles (MMPs-Apt1) and quantum dots (QDs-Apt2). The dual-aptamer logic gate simplifies the discrimination results of PrP(Res), leaving the detection of PrP(Res) either "yes" or "no". The development of OR logic gate based on dual-aptamer strategy and two chemical input signals (PrP(Res) and Gdn-HCl) is an important step toward the design of prion diseases diagnosis and therapy systems.
Review of Research on Sight Word Instruction.
ERIC Educational Resources Information Center
Browder, Diane M.; Lalli, Joseph S.
1991-01-01
This review of 20 years of literature on sight word instruction for individuals with handicaps examines effectiveness data for procedures teaching word recognition and comprehension. Covered are "errorless procedures," prompt elimination, stimulus fading, time delay, easy to hard discrimination, and trial and error with feedback. Two tables…
Observing Behavior and Atypically Restricted Stimulus Control
ERIC Educational Resources Information Center
Dube, William V.; Dickson, Chata A.; Balsamo, Lyn M.; O'Donnell, Kristin Lombard; Tomanari, Gerson Y.; Farren, Kevin M.; Wheeler, Emily E.; McIlvane, William J.
2010-01-01
Restricted stimulus control refers to discrimination learning with atypical limitations in the range of controlling stimuli or stimulus features. In the study reported here, 4 normally capable individuals and 10 individuals with intellectual disabilities (ID) performed two-sample delayed matching to sample. Sample-stimulus observing was recorded…
Okazaki, Masato; Pander, Piotr; Higginbotham, Heather; Monkman, Andrew P.
2017-01-01
Novel U-shaped donor–acceptor–donor (D–A–D) π-conjugated multi-functional molecules comprising dibenzo[a,j]phenazine (DBPHZ) as an acceptor and phenothiazines (PTZ) as donors have been developed. Most importantly, the D–A–D compounds exhibit not only distinct tricolor-changeable mechanochromic luminescence (MCL) properties but also efficient thermally activated delayed fluorescence (TADF). Quantum chemical calculations, X-ray diffraction analysis, and systematic studies on the photophysical properties indicated that the “two-conformation-switchable” PTZ units play a highly important role in achieving multi-color-changing MCL. Time-resolved photophysical measurements revealed that the developed D–A–D compounds also exhibit efficient orange-TADF. Furthermore, organic light-emitting diode (OLED) devices fabricated with the new TADF emitters have achieved high external quantum efficiencies (EQEs) up to 16.8%, which significantly exceeds the theoretical maximum (∼5%) of conventional fluorescent emitters. PMID:28553504
Study on optoelectronic properties of Spiro-CN for developing an efficient OLED
NASA Astrophysics Data System (ADS)
Mishra, Ashok Kumar
2018-05-01
There are a class of organic molecules and polymers which exhibit semiconductor behavior because of nearly free conjugate π-electrons. Hopping of these electrons in molecules forms different excited singlet and triplet states named as excitons. Some of these organic molecules can be set to emit photons by triplet-singlet excitonic transition via a process called Thermally Activated Delayed Fluorescence (TADF) which is exploited for designing the Organic Light Emitting diode (OLED.) Spiro-CN (spirobifluorene skeletons) Spiro is one of these reported noble metal-free TADF molecules which offers unique optical and electronic properties arising from the efficient transition and reverse intersystem crossing between the lowest singlet (S) and triplet (T) excited states. Its ability to harvest triplet excitons for fluorescence through facilitated reverse intersystem crossing (T→S) could directly impact their properties and performances, which is attractive for a wide variety of low-cost optoelectronic device. In the present study, the Spiro-CN compounds have been taken up for the investigation of various optoelectronic properties including the thermally activated delayed fluorescence (TADF) by using the Koopmans Method and Density Functional Theory. The present study discusses the utility of the Spiro-CN organic semiconductor as a suitable TADF material essential for developing an efficient Organic Light Emitting Diode (OLED).
Shao, Jing; Sun, Junqiang
2012-08-15
We propose and experimentally demonstrate a simple and flexible photonic scheme for generation and modulation of ultrawideband (UWB) using a phase modulator and a fiber delay interferometer (DI)-based multichannel frequency discrimination. By introducing a Gaussian signal to the phase modulator, the UWB polarity-switchable doublet pulses can be achieved by combining the pair of UWB monocycle pulses with inverted polarities at the DI outputs under proper time delay. Furthermore, the pulse shape modulation, pulse position modulation, and on-off keying can be performed by coding the electrical data patterns and adjusting the time delay between the two monocycle pulses. Only a laser source introduced in the architecture guarantees the excellent dispersion tolerance over 75 km optical fiber link for UWB pulse sequence, which has potential application in future high-speed UWB impulse radio over optical fiber access networks.
Tseng, Yen-Cheng; Guo, How-Ran; Lai, Der-Chung
2016-01-01
With globalization, transnational marriages become more and more common around the world. Children born to immigrant mothers might be more likely to have developmental delays, but studies on this topic are limited and with inconsistent results. To determine whether children born to immigrant mothers are more likely to have developmental delays. We analyzed the data from the national registry of children with developmental delays from 2009 to 2013 and compared the incidence of developmental delays between children born to immigrant mothers and native mothers. We also performed stratified analyses by age, sex, and geographic area. From 2009 to 2013, 78,946 new cases of developmental delays under 6 years of age were registered, including 5619 (7.1%) born to immigrant mothers. The incidence was higher in children born to native mothers in every year with rate ratios ranging from 1.32 to 1.48, and the differences reached statistical significance even after stratification by age, sex, and geographic area. Children born to immigrant mothers had lower incidence of developmental delays in Taiwan. The result may help reduce the discrimination of foreign spouses and their children. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jia, Chuandong; Zuo, Wei; Yang, Dong; Chen, Yanming; Cao, Liping; Custelcean, Radu; Hostaš, Jiří; Hobza, Pavel; Glaser, Robert; Wang, Yao-Yu; Yang, Xiao-Juan; Wu, Biao
2017-10-16
In nature, proteins have evolved sophisticated cavities tailored for capturing target guests selectively among competitors of similar size, shape, and charge. The fundamental principles guiding the molecular recognition, such as self-assembly and complementarity, have inspired the development of biomimetic receptors. In the current work, we report a self-assembled triple anion helicate (host 2) featuring a cavity resembling that of the choline-binding protein ChoX, as revealed by crystal and density functional theory (DFT)-optimized structures, which binds choline in a unique dual-site-binding mode. This similarity in structure leads to a similarly high selectivity of host 2 for choline over its derivatives, as demonstrated by the NMR and fluorescence competition experiments. Furthermore, host 2 is able to act as a fluorescence displacement sensor for discriminating choline, acetylcholine, L-carnitine, and glycine betaine effectively.The choline-binding protein ChoX exhibits a synergistic dual-site binding mode that allows it to discriminate choline over structural analogues. Here, the authors design a biomimetic triple anion helicate receptor whose selectivity for choline arises from a similar binding mechanism.
Limitations to photosynthesis under light and heat stress in three high-yielding wheat genotypes.
Monneveux, Philippe; Pastenes, Claudio; Reynolds, Matthew P
2003-06-01
Three high-yielding wheat genotypes (T. aestivum L., c.v. Siete Cerros, Seri and Bacanora, released in 1966, 1982 and 1988, respectively) were grown under irrigation in two high radiation, low relative humidity environments (Tlaltizapan and Ciudad Obregon CIMMYT experimental stations, Mexico). Gas exchange and fluorescence parameters were assessed on the flag leaf during the day. Carbon isotope discrimination (delta) was analysed in flag leaf at anthesis and in grain at maturity. In both environments, gas exchange and fluorescence parameters varied markedly with irradiance and temperature. Analysis of their respective variation indicated the occurrence of photo-respiration and photo-inhibition, particularly in Tlaltizapan, the warmest environment, and in Siete Cerros. In Ciudad Obregon (high-yielding environment) lower Ci (internal CO2 concentration) and delta La (carbon isotope discrimination of the leaf) suggested a higher intrinsic photosynthetic capacity in the variety Bacanora. Higher yield of this genotype was also associated with higher Fv'/Fo' (ratio of photochemical and non photochemical rate constants in the light) and Fm'/Fm (ratio of the non photochemical rate constants in the dark and light adapted state).
Designing a new type of neutron detector for neutron and gamma-ray discrimination via GEANT4.
Shan, Qing; Chu, Shengnan; Ling, Yongsheng; Cai, Pingkun; Jia, Wenbao
2016-04-01
Design of a new type of neutron detector, consisting of a fast neutron converter, plastic scintillator, and Cherenkov detector, to discriminate 14-MeV fast neutrons and gamma rays in a pulsed n-γ mixed field and monitor their neutron fluxes is reported in this study. Both neutrons and gamma rays can produce fluorescence in the scintillator when they are incident on the detector. However, only the secondary charged particles of the gamma rays can produce Cherenkov light in the Cherenkov detector. The neutron and gamma-ray fluxes can be calculated by measuring the fluorescence and Cherenkov light. The GEANT4 Monte Carlo simulation toolkit is used to simulate the whole process occurring in the detector, whose optimum parameters are known. Analysis of the simulation results leads to a calculation method of neutron flux. This method is verified by calculating the neutron fluxes using pulsed n-γ mixed fields with different n/γ ratios, and the results show that the relative errors of all calculations are <5%. Copyright © 2016 Elsevier Ltd. All rights reserved.
Standoff detection and classification of bacteria by multispectral laser-induced fluorescence
NASA Astrophysics Data System (ADS)
Duschek, Frank; Fellner, Lea; Gebert, Florian; Grünewald, Karin; Köhntopp, Anja; Kraus, Marian; Mahnke, Peter; Pargmann, Carsten; Tomaso, Herbert; Walter, Arne
2017-04-01
Biological hazardous substances such as certain fungi and bacteria represent a high risk for the broad public if fallen into wrong hands. Incidents based on bio-agents are commonly considered to have unpredictable and complex consequences for first responders and people. The impact of such an event can be minimized by an early and fast detection of hazards. The presented approach is based on optical standoff detection applying laser-induced fluorescence (LIF) on bacteria. The LIF bio-detector has been designed for outdoor operation at standoff distances from 20 m up to more than 100 m. The detector acquires LIF spectral data for two different excitation wavelengths (280 and 355 nm) which can be used to classify suspicious samples. A correlation analysis and spectral classification by a decision tree is used to discriminate between the measured samples. In order to demonstrate the capabilities of the system, suspensions of the low-risk and non-pathogenic bacteria Bacillus thuringiensis, Bacillus atrophaeus, Bacillus subtilis, Brevibacillus brevis, Micrococcus luteus, Oligella urethralis, Paenibacillus polymyxa and Escherichia coli (K12) have been investigated with the system, resulting in a discrimination accuracy of about 90%.
Pope, Derek A; Boomhower, Steven R; Hutsell, Blake A; Teixeira, Kathryn M; Newland, M Christopher
2016-04-01
Adolescence is marked by the continued development of the neural pathways that support choice and decision-making, particularly those involving dopamine signaling. Cocaine exposure during adolescence may interfere with this development and manifest as increased perseveration and delay discounting in adulthood, behavioral processes that are related to drug addiction. Adolescent mice were exposed to 30mg/kg/day of cocaine (n=11) or saline vehicle (n=10) for 14days and behavior was assessed in adulthood. In Experiment 1, performance on a spatial-discrimination-reversal procedure was evaluated. In the first two sessions following the first reversal, cocaine-exposed mice produced more preservative errors relative to controls. In Experiment 2, cocaine-exposed mice displayed steeper delay discounting than saline-exposed mice, effects that were reversed by acute cocaine administration. Experiment 3 examined responding maintained by a range of fixed-ratio schedules of reinforcement. An analysis based on a theoretical framework called Mathematical Principles of Reinforcement (MPR) was applied to response-rate functions of individual mice. According to MPR, differences in response-rate functions in adulthood were due to a steepening of the delay-of-reinforcement gradient, disrupted motoric capacity (lower maximum response rates), and enhanced reinforcer efficacy for the adolescent cocaine- compared with saline-exposed mice. Overall, these experiments suggest that chronic exposure to cocaine during adolescence may impair different features of 'executive functions' in adulthood, and these may be related to distortions in the impact of reinforcing events. Copyright © 2016 Elsevier Inc. All rights reserved.
Cao, Ruofan; Naivar, Mark A; Wilder, Mark; Houston, Jessica P
2014-01-01
Fluorescence lifetime measurements provide information about the fluorescence relaxation, or intensity decay, of organic fluorophores, fluorescent proteins, and other inorganic molecules that fluoresce. The fluorescence lifetime is emerging in flow cytometry and is helpful in a variety of multiparametric, single cell measurements because it is not impacted by nonlinearity that can occur with fluorescence intensity measurements. Yet time-resolved cytometry systems rely on major hardware modifications making the methodology difficult to reproduce. The motivation of this work is, by taking advantage of the dynamic nature of flow cytometry sample detection and applying digital signal processing methods, to measure fluorescence lifetimes using an unmodified flow cytometer. We collect a new lifetime-dependent parameter, referred to herein as the fluorescence-pulse-delay (FPD), and prove it is a valid representation of the average fluorescence lifetime. To verify we generated cytometric pulses in simulation, with light emitting diode (LED) pulsation, and with true fluorescence measurements of cells and microspheres. Each pulse is digitized and used in algorithms to extract an average fluorescence lifetime inherent in the signal. A range of fluorescence lifetimes is measurable with this approach including standard organic fluorophore lifetimes (∼1 to 22 ns) as well as small, simulated shifts (0.1 ns) under standard conditions (reported herein). This contribution demonstrates how digital data acquisition and signal processing can reveal time-dependent information foreshadowing the exploitation of full waveform analysis for quantification of similar photo-physical events within single cells. © 2014 The Authors. Published by Wiley Periodicals, Inc. PMID:25274073
Brain Mechanisms Supporting Discrimination of Sensory Features of Pain: A New Model
Oshiro, Yoshitetsu; Quevedo, Alexandre S.; McHaffie, John G.; Kraft, Robert A.; Coghill, Robert C.
2010-01-01
Pain can be very intense or only mild, and can be well localized or diffuse. To date, little is known as to how such distinct sensory aspects of noxious stimuli are processed by the human brain. Using functional magnetic resonance imaging and a delayed match-to-sample task, we show that discrimination of pain intensity, a non-spatial aspect of pain, activates a ventrally directed pathway extending bilaterally from the insular cortex to the prefrontal cortex. This activation is distinct from the dorsally-directed activation of the posterior parietal cortex and right dorsolateral prefrontal cortex that occurs during spatial discrimination of pain. Both intensity and spatial discrimination tasks activate highly similar aspects of the anterior cingulate cortex, suggesting that this structure contributes to common elements of the discrimination task such as the monitoring of sensory comparisons and response selection. Taken together, these results provide the foundation for a new model of pain in which bidirectional dorsal and ventral streams preferentially amplify and process distinct sensory features of noxious stimuli according to top-down task demands. PMID:19940188
Sun, Yinghua; Sun, Yang; Stephens, Douglas; Xie, Hongtao; Phipps, Jennifer; Saroufeem, Ramez; Southard, Jeffrey; Elson, Daniel S.; Marcu, Laura
2011-01-01
Simultaneous time- and wavelength-resolved fluorescence spectroscopy (STWRFS) was developed and tested for the dynamic characterization of atherosclerotic tissue ex vivo and arterial vessels in vivo. Autofluorescence, induced by a 337 nm, 700 ps pulsed laser, was split to three wavelength sub-bands using dichroic filters, with each sub-band coupled into a different length of optical fiber for temporal separation. STWRFS allows for fast recording/analysis (few microseconds) of time-resolved fluorescence emission in these sub-bands and rapid scanning. Distinct compositions of excised human atherosclerotic aorta were clearly discriminated over scanning lengths of several centimeters based on fluorescence lifetime and the intensity ratio between 390 and 452 nm. Operation of STWRFS blood flow was further validated in pig femoral arteries in vivo using a single-fiber probe integrated with an ultrasound imaging catheter. Current results demonstrate the potential of STWRFS as a tool for real-time optical characterization of arterial tissue composition and for atherosclerosis research and diagnosis. PMID:21369214
Label-free imaging and spectroscopy for early detection of cervical cancer.
Jing, Yueyue; Wang, Yulan; Wang, Xinyi; Song, Chuan; Ma, Jiong; Xie, Yonghui; Fei, Yiyan; Zhang, Qinghua; Mi, Lan
2018-05-01
The label-free imaging and spectroscopy method was studied on cervical unstained tissue sections obtained from 36 patients. The native fluorescence spectra of tissues are analyzed by the optical redox ratio (ORR), which is defined as fluorescence intensity ratio between NADH and FAD, and indicates the metabolism change with the cancer development. The ORRs of normal tissues are consistently higher than those of precancer or cancerous tissues. A criterion line of ORR at 5.0 can be used to discriminate cervical precancer/cancer from normal tissues. The sensitivity and specificity of the native fluorescence spectroscopy method for cervical cancer diagnosis are determined as 100% and 91%. Moreover, the native fluorescence spectroscopy study is much more sensitive on the healthy region of cervical precancer/cancer patients compared with the traditional clinical staining method. The results suggest label-free imaging and spectroscopy is a fast, highly sensitive and specific method on the detection of cervical cancer. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Wang, Ming-Qi; Ren, Gui-Ying; Zhao, Shuang; Lian, Guang-Chang; Chen, Ting-Ting; Ci, Yang; Li, Hong-Yao
2018-06-01
G-quadruplex DNAs are highly prevalent in the human genome and involved in many important biological processes. However, many aspects of their biological mechanism and significance still need to be elucidated. Therefore, the development of fluorescent probes for G-quadruplex detection is important for the basic research. We report here on the development of small molecular dyes designed on the basis of carbazole scaffold by introducing styrene-like substituents at its 9-position, for the purpose of G-quadruplex recognition. Results revealed that the side group on the carbazole scaffold was very important for their ability to selectively recognize G-quadruplex DNA structures. 1a with the pyridine side group displayed excellent fluorescence signal turn-on property for the specific discrimination of G-quadruplex DNAs against other nucleic acids. The characteristics of 1a were further investigated with UV-vis spectrophotometry, fluorescence, circular dichroism, FID assay and molecular docking to validate the selectivity, sensitivity and detailed binding mode toward G-quadruplex DNAs.
Chen, Fengzao; Han, Deman; Gao, Yuan; Liu, Heng; Wang, Shengfu; Zhou, Fangyu; Li, Kaibin; Zhang, Siqi; Shao, Wujun; He, Yanling
2018-09-01
Hydrogen sulfide and biothiol molecules such as Cys, Hcy, and GSH play important roles in biological systems. Exploiting a probe to simultaneously detect and distinguish them is quite important. In this work, a versatile fluorescent probe that can simultaneously detect and discriminate Cys/Hcy and H 2 S is reported. The probe easily prepared by the Knoevenagel condensation of cyanoacetylindole with chlorinated phenyl-propenal possessed three potential sites that could react with biothiols and H 2 S. This probe also exhibited rapidity, high selectivity, and sensitivity for Cys/Hcy and H 2 S with distinct optical signal changes. The probe was able to display obvious fluorescence enhancement at 480 nm for Cys/Hcy and unique absorbance enhancement at 500 nm for H 2 S. We also demonstrated that the probe can be successfully applied to image Cys in MCF-7 cells suing a confocal fluorescence microscope. Copyright © 2018 Elsevier B.V. All rights reserved.
Fegade, Umesh A; Sahoo, Suban K; Singh, Amanpreet; Singh, Narinder; Attarde, Sanjay B; Kuwar, Anil S
2015-05-04
A fluorescent based receptor (4Z)-4-(4-diethylamino)-2-hydroxybenzylidene amino)-1,2dihydro-1,5-dimethyl-2-phenylpyrazol-3-one (receptor 3) was developed for the highly selective and sensitive detection of Cu(2+) and Zn(2+) in semi-aqueous system. The fluorescence of receptor 3 was enhanced and quenched, respectively, with the addition of Zn(2+) and Cu(2+) ions over other surveyed cations. The receptor formed host-guest complexes in 1:1 stoichiometry with the detection limit of 5 nM and 15 nM for Cu(2+) and Zn(2+) ions, respectively. Further, we have effectively utilized the two metal ions (Cu(2+) and Zn(2+)) as chemical inputs for the manufacture of INHIBIT type logic gate at molecular level using the fluorescence responses of receptor 3 at 450 nm. Copyright © 2015 Elsevier B.V. All rights reserved.
A passive two-band sensor of sunlight-excited plant fluorescence
NASA Astrophysics Data System (ADS)
Kebabian, Paul L.; Theisen, Arnold F.; Kallelis, Spiros; Freedman, Andrew
1999-11-01
We have designed and built a passive remote sensor of sunlight-excited chlorophyll fluorescence (U.S. Patent No. 5,567,947, Oct. 22, 1996) which provides for the real-time, in situ sensing of photosynthetic activity in plants. This sensor, which operates as a Fraunhofer line discriminator, detects light at the cores of the lines comprising the atmospheric oxygen A and B bands, centered at 762 and 688 nm, respectively. These bands also correspond to wavelengths in the far-red and red chlorophyll fluorescence bands. The sensor is based on an induced fluorescence approach; as light collected from fluorescing plants is passed through a low-pressure cell containing oxygen, the oxygen absorbs the energy and subsequently reemits photons which are then detected by a photomultiplier tube. Since the oxygen in the cell absorbs light at the same wavelengths that have been strongly absorbed by the oxygen in the atmosphere, the response to incident sunlight is minimal. This mode of measurement is limited to target plants sufficiently close in range that the plants' fluorescence is not itself appreciably absorbed by atmospheric oxygen (˜200 m). In vivo measurements of fluorescence in the 760 and 690 nm bands of vegetation in full sunlight are also presented. Measurements of plant fluorescence at the single-plant canopy level were obtained from greenhouse-grown bean plants subjected to a range of nitrogen treatments. The ratio of the fluorescence obtained from the two measurement bands showed statistically significant variation with respect to nitrogen treatments.
Revealing the spin–vibronic coupling mechanism of thermally activated delayed fluorescence
Etherington, Marc K.; Gibson, Jamie; Higginbotham, Heather F.; Penfold, Thomas J.; Monkman, Andrew P.
2016-01-01
Knowing the underlying photophysics of thermally activated delayed fluorescence (TADF) allows proper design of high efficiency organic light-emitting diodes. We have proposed a model to describe reverse intersystem crossing (rISC) in donor–acceptor charge transfer molecules, where spin–orbit coupling between singlet and triplet states is mediated by one of the local triplet states of the donor (or acceptor). This second order, vibronically coupled mechanism describes the basic photophysics of TADF. Through a series of measurements, whereby the energy ordering of the charge transfer (CT) excited states and the local triplet are tuned in and out of resonance, we show that TADF reaches a maximum at the resonance point, substantiating our model of rISC. Moreover, using photoinduced absorption, we show how the populations of both singlet and triplet CT states and the local triplet state change in and out of resonance. Our vibronic coupling rISC model is used to predict this behaviour and describes how rISC and TADF are affected by external perturbation. PMID:27901046
Shao, Shiyang; Hu, Jun; Wang, Xingdong; Wang, Lixiang; Jing, Xiabin; Wang, Fosong
2017-12-13
We demonstrate novel molecular design for thermally activated delayed fluorescence (TADF) polymers based on a nonconjugated polyethylene backbone with through-space charge transfer effect between pendant electron donor (D) and acceptor (A) units. Different from conventional conjugated D-A polymers with through-bond charge transfer effect, the nonconjugated architecture avoids direct conjugation between D and A units, enabling blue emission. Meanwhile, spatial π-π interaction between the physically separated D and A units results in both small singlet-triplet energy splitting (0.019 eV) and high photoluminescence quantum yield (up to 60% in film state). The resulting polymer with 5 mol % acceptor unit gives efficient blue electroluminescence with Commission Internationale de l'Eclairage coordinates of (0.176, 0.269), together with a high external quantum efficiency of 12.1% and low efficiency roll-off of 4.9% (at 1000 cd m -2 ), which represents the first example of blue TADF nonconjugated polymer.
Matsuoka, Kenichi; Albrecht, Ken; Yamamoto, Kimihisa; Fujita, Katsuhiko
2017-01-01
Thermally activated delayed fluorescence (TADF) materials emerged as promising light sources in third generation organic light-emitting diodes (OLED). Much effort has been invested for the development of small molecular TADF materials and vacuum process-based efficient TADF-OLEDs. In contrast, a limited number of solution processable high-molecular weight TADF materials toward low cost, large area, and scalable manufacturing of solution processed TADF-OLEDs have been reported so far. In this context, we report benzophenone-core carbazole dendrimers (GnB, n = generation) showing TADF and aggregation-induced emission enhancement (AIEE) properties along with alcohol resistance enabling further solution-based lamination of organic materials. The dendritic structure was found to play an important role for both TADF and AIEE activities in the neat films. By using these multifunctional dendritic emitters as non-doped emissive layers, OLED devices with fully solution processed organic multilayers were successfully fabricated and achieved maximum external quantum efficiency of 5.7%. PMID:28139768
Hosokai, Takuya; Matsuzaki, Hiroyuki; Nakanotani, Hajime; Tokumaru, Katsumi; Tsutsui, Tetsuo; Furube, Akihiro; Nasu, Keirou; Nomura, Hiroko; Yahiro, Masayuki; Adachi, Chihaya
2017-01-01
The design of organic compounds with nearly no gap between the first excited singlet (S1) and triplet (T1) states has been demonstrated to result in an efficient spin-flip transition from the T1 to S1 state, that is, reverse intersystem crossing (RISC), and facilitate light emission as thermally activated delayed fluorescence (TADF). However, many TADF molecules have shown that a relatively appreciable energy difference between the S1 and T1 states (~0.2 eV) could also result in a high RISC rate. We revealed from a comprehensive study of optical properties of TADF molecules that the formation of delocalized states is the key to efficient RISC and identified a chemical template for these materials. In addition, simple structural confinement further enhances RISC by suppressing structural relaxation in the triplet states. Our findings aid in designing advanced organic molecules with a high rate of RISC and, thus, achieving the maximum theoretical electroluminescence efficiency in organic light-emitting diodes. PMID:28508081
NASA Astrophysics Data System (ADS)
Matsuoka, Kenichi; Albrecht, Ken; Yamamoto, Kimihisa; Fujita, Katsuhiko
2017-01-01
Thermally activated delayed fluorescence (TADF) materials emerged as promising light sources in third generation organic light-emitting diodes (OLED). Much effort has been invested for the development of small molecular TADF materials and vacuum process-based efficient TADF-OLEDs. In contrast, a limited number of solution processable high-molecular weight TADF materials toward low cost, large area, and scalable manufacturing of solution processed TADF-OLEDs have been reported so far. In this context, we report benzophenone-core carbazole dendrimers (GnB, n = generation) showing TADF and aggregation-induced emission enhancement (AIEE) properties along with alcohol resistance enabling further solution-based lamination of organic materials. The dendritic structure was found to play an important role for both TADF and AIEE activities in the neat films. By using these multifunctional dendritic emitters as non-doped emissive layers, OLED devices with fully solution processed organic multilayers were successfully fabricated and achieved maximum external quantum efficiency of 5.7%.
Revealing the spin-vibronic coupling mechanism of thermally activated delayed fluorescence
NASA Astrophysics Data System (ADS)
Etherington, Marc K.; Gibson, Jamie; Higginbotham, Heather F.; Penfold, Thomas J.; Monkman, Andrew P.
2016-11-01
Knowing the underlying photophysics of thermally activated delayed fluorescence (TADF) allows proper design of high efficiency organic light-emitting diodes. We have proposed a model to describe reverse intersystem crossing (rISC) in donor-acceptor charge transfer molecules, where spin-orbit coupling between singlet and triplet states is mediated by one of the local triplet states of the donor (or acceptor). This second order, vibronically coupled mechanism describes the basic photophysics of TADF. Through a series of measurements, whereby the energy ordering of the charge transfer (CT) excited states and the local triplet are tuned in and out of resonance, we show that TADF reaches a maximum at the resonance point, substantiating our model of rISC. Moreover, using photoinduced absorption, we show how the populations of both singlet and triplet CT states and the local triplet state change in and out of resonance. Our vibronic coupling rISC model is used to predict this behaviour and describes how rISC and TADF are affected by external perturbation.
First results of the delayed fluorescence velocimetry as applied to diesel spray diagnostics
NASA Astrophysics Data System (ADS)
Megahed, M.; Roosen, P.
1993-08-01
One of the main parameters governing diesel spray formation is the fuel's velocity just beneath the nozzle. The high density of the injected liquid within the first few millimeters under the injector prohibits accurate measurements of this velocity. The liquid's velocity in this region has been mainly measured using intrusive methods and has been numerically calculated without considering the complex flow fields in the nozzle. A new optical method based on laser induced delayed fluorescence allowing the measurement of the fuel's velocity close to the nozzle is reported. The results are accurate to about 14% and represent the velocities of heavy oils within the first 2 - 5 mm beneath the nozzle. The development of the velocity over the injection period showed a drastic deceleration of the fuel within the first 3 mm beneath the nozzle. This is assumed to be due to the complex interaction of cavitation in the injection hole and pressure waves in the injection system which causes the start of atomization in the nozzle hole.
Jeong, J-W; Sundaram, S; Behen, M E; Chugani, H T
2016-06-01
Pure speech delay is a common developmental disorder which, according to some estimates, affects 5%-8% of the population. Speech delay may not only be an isolated condition but also can be part of a broader condition such as global developmental delay. The present study investigated whether diffusion tensor imaging tractography-based connectome can differentiate global developmental delay from speech delay in young children. Twelve children with pure speech delay (39.1 ± 20.9 months of age, 9 boys), 14 children with global developmental delay (39.3 ± 18.2 months of age, 12 boys), and 10 children with typical development (38.5 ± 20.5 months of age, 7 boys) underwent 3T DTI. For each subject, whole-brain connectome analysis was performed by using 116 cortical ROIs. The following network metrics were measured at individual regions: strength (number of the shortest paths), efficiency (measures of global and local integration), cluster coefficient (a measure of local aggregation), and betweeness (a measure of centrality). Compared with typical development, global and local efficiency were significantly reduced in both global developmental delay and speech delay (P < .0001). The nodal strength of the cognitive network is reduced in global developmental delay, whereas the nodal strength of the language network is reduced in speech delay. This finding resulted in a high accuracy of >83% ± 4% to discriminate global developmental delay from speech delay. The network abnormalities identified in the present study may underlie the neurocognitive and behavioral consequences commonly identified in children with global developmental delay and speech delay. Further validation studies in larger samples are required. © 2016 by American Journal of Neuroradiology.
Noninvasive fluorescence excitation spectroscopy for the diagnosis of oral neoplasia in vivo
NASA Astrophysics Data System (ADS)
Ebenezar, Jeyasingh; Ganesan, Singaravelu; Aruna, Prakasarao; Muralinaidu, Radhakrishnan; Renganathan, Kannan; Saraswathy, Thillai Rajasekaran
2012-09-01
Fluorescence excitation spectroscopy (FES) is an emerging approach to cancer detection. The goal of this pilot study is to evaluate the diagnostic potential of FES technique for the detection and characterization of normal and cancerous oral lesions in vivo. Fluorescence excitation (FE) spectra from oral mucosa were recorded in the spectral range of 340 to 600 nm at 635 nm emission using a fiberoptic probe spectrofluorometer to obtain spectra from the buccal mucosa of 30 sites of 15 healthy volunteers and 15 sites of 10 cancerous patients. Significant FE spectral differences were observed between normal and well differentiated squamous cell carcinoma (WDSCC) oral lesions. The FE spectra of healthy volunteers consists of a broad emission band around 440 to 470 nm, whereas in WDSCC lesions, a new primary peak was seen at 410 nm with secondary peaks observed at 505, 540, and 580 nm due to the accumulation of porphyrins in oral lesions. The FE spectral bands of the WDSCC lesions resemble the typical absorption spectra of a porphyrin. Three potential ratios (I410/I505, I410/I540, and I410/I580) were calculated from the FE spectra and used as input variables for a stepwise linear discriminant analysis (SLDA) for normal and WDSCC groups. Leave-one-out (LOO) method of cross-validation was performed to check the reliability on spectral data for tissue characterization. The diagnostic sensitivity and specificity were determined for normal and WDSCC lesions from the scatter plot of the discriminant function scores. It was observed that diagnostic algorithm based on discriminant function scores obtained by SLDA-LOO method was able to distinguish WDSCC from normal lesions with a sensitivity of 100% and specificity of 100%. Results of the pilot study demonstrate that the FE spectral changes due to porphyrin have a good diagnostic potential; therefore, porphyrin can be used as a native tumor marker.
Ouchi, Kazuki; Colyer, Christa L; Sebaiy, Mahmoud; Zhou, Jin; Maeda, Takeshi; Nakazumi, Hiroyuki; Shibukawa, Masami; Saito, Shingo
2015-02-03
We designed a new series of boronic acid-functionalized squarylium cyanine dyes (SQ-BA) with different lengths of alkyl chain residues, suitable for multiple discriminant analysis (MDA) of sialic acid (Neu5Ac) in biological samples. The SQ-BA dyes form aggregates based on hydrophobic interactions, which result in quenched fluorescence in aqueous solutions. When the boronic acid binds with saccharides, the fluorescence intensity increases as a result of dissociation to the emissive monomeric complex. We inferred that different dye aggregate structures (H-aggregates and J-aggregates) were induced depending on the alkyl chain length, so that monosaccharides would be recognized in different ways (especially, multipoint interaction with J-aggregates). A distinctive emission enhancement of SQ-BA dyes with shorter-alkyl-chains in the presence of Neu5Ac was observed (2.4-fold fluorescence enhancement; with formation constant 10(1.7) M(-1)), with no such enhancement for SQ-BA dyes with longer-alkyl-chain. In addition, various enhancement factors for other monosaccharides were observed depending on the alkyl chain length. Detailed thermodynamic and NMR studies of the SQ-BA complexes revealed the unique recognition mechanism: the dye aggregate with a shorter-alkyl-chain causes the slipped parallel structure and forms a stable 2:1 complex with Neu5Ac, as distinct from longer-alkyl-chain dyes, which form a 1:1 monomeric complex. MDA using the four SQ-BA dyes was performed for human urine samples, resulting in the successful discrimination between normal and abnormal Neu5Ac levels characteristic of disease. Thus, we successfully controlled various responses to similar monosaccharides with a novel approach that chemically modified not the boronic acid moiety itself but the length of the alkyl chain residue attached to the dye in order to generate specificity.
Dysgraphia in Children: Lasting Psychomotor Deficiency or Transient Developmental Delay?
ERIC Educational Resources Information Center
Smits-Engelsman, Bouwien C. M.; Van Galen, Gerard P.
1997-01-01
Used writing tasks recorded on a computer-monitored XY tablet to differentiate between normal variations in psychomotor development and dysgraphia in 16 young children. Found that control of spatial accuracy, not allograph retrieval or size control, discriminated dysgraphic children from others. Poor writers were less accurate than proficient…
Biological and remote sensing perspectives of pigmentation in coral reef organisms.
Hedley, John D; Mumby, Peter J
2002-01-01
Coral reef communities face unprecedented pressures on local, regional and global scales as a consequence of climate change and anthropogenic disturbance. Optical remote sensing, from satellites or aircraft, is possibly the only means of measuring the effects of such stresses at appropriately large spatial scales (many thousands of square kilometres). To map key variables such as coral community structure, percentages of living coral or percentages of dead coral, a remote sensing instrument must be able to distinguish the reflectance spectra (i.e. "spectral signature", reflected light as a function of wavelength) of each category. For biotic classes, reflectance is a complex function of pigmentation, structure and morphology. Studies of coral "colour" fall into two disparate but potentially complementary types. Firstly, biological studies tend to investigate the structure and significance of pigmentation in reef organisms. These studies often lack details that would be useful from a remote sensing perspective such as intraspecific variation in pigment concentration or the contribution of fluorescence to reflectance. Secondly, remote sensing studies take empirical measurements of spectra and seek wavelengths that discriminate benthic categories. Benthic categories used in remote sensing sometimes consist of species groupings that are biologically or spectrally inappropriate (e.g. merging of algal phyla with distinct pigments). Here, we attempt to bridge the gap between biological and remote sensing perspectives of pigmentation in reef taxa. The aim is to assess the extent to which spectral discrimination can be given a biological foundation, to reduce the ad hoc nature of discriminatory criteria, and to understand the fundamental (biological) limitations in the spectral separability of biotic classes. Sources of pigmentation in reef biota are reviewed together with remote sensing studies where spectral discrimination has been effectively demonstrated between benthic categories. The basis of reflectance is considered as the sum of pigmented components, such as zooxanthellae, host tissues and skeletons of corals. Problems in the empirical in situ measurement of reflectance are identified, such as the differing types of reflectance which can be measured, the interaction of the light field with morphology, and depth-dependent variability of measured reflectance due to fluorescence. The latter is estimated in some cases to introduce an error of up to 20% when depth differs by 8 m. Spectral features useful in discriminating reef benthos are identified and related to pigmentation. The slope in the reflectance spectra between 650 and 690 nm is dependent on chlorophyll-a concentration and can be used to discriminate bare sand with no algal component from chlorophyll-a containing benthos (algae, corals). The slope in reflectance at various locations between 500 and 560 nm can be useful in discriminating bleached and unbleached corals, possibly due to reduced peridinin concentration. Rhodophyta may be discernible by the presence of a dip in reflectance at 570 nm, due to a phycoerythrin absorption peak. However, the utility of some discriminatory criteria in deeper waters is mitigated by the relatively poor transmission of light through water at longer wavelengths (especially > 600 nm). Contrary to suggested categorizations of fluorescent pigments in coral host tissues, it is shown that these pigments form an almost continuous distribution with respect to their excitation and emission peaks. Remote sensing by induced fluorescence is a promising approach, but further details about the variation and distribution of these pigments are required. It is hoped that this review will promote cross-disciplinary collaboration between pigment biologists and the reef remote sensing community. Where possible, the discriminative criteria adopted in remote sensing should be related to biological phenomena, thus lending an intuitive, process-orientated basis for interpreting spectral data. Similarly, remote sensing may provide a novel scaling perspective to biological studies of pigmentation in reef organisms.
Role Played by the Passage of Time in Reversal Learning.
Goarin, Estelle H F; Lingawi, Nura W; Laurent, Vincent
2018-01-01
Reversal learning is thought to involve an extinction-like process that inhibits the expression of the initial learning. However, behavioral evidence for this inhibition remains difficult to interpret as various procedures have been employed to study reversal learning. Here, we used a discrimination task in rats to examine whether the inhibition produced by reversal learning is as sensitive to the passage of time as the inhibition produced by extinction. Experiment 1 showed that when tested immediately after reversal training, rats were able to use the reversed contingencies to solve the discrimination task in an outcome-specific manner. This ability to use outcome-specific information was lost when a delay was inserted between reversal training and test. However, interpretation of these data was made difficult by a potential floor effect. This concern was addressed in Experiment 2 in which it was confirmed that the passage of time impaired the ability of the rats to use the reversed contingencies in an outcome-specific manner to solve the task. Further, it revealed that the delay between initial learning and test was not responsible for this impairment. Additional work demonstrated that solving the discrimination task was unaffected by Pavlovian extinction but that the discriminative stimuli were able to block conditioning to a novel stimulus, suggesting that Pavlovian processes were likely to contribute to solving the discrimination. We therefore concluded that the expression of reversal and extinction learning do share the same sensitivity to the effect of time. However, this sensitivity was most obvious when we assessed outcome-specific information following reversal learning. This suggests that the processes involved in reversal learning are somehow distinct from those underlying extinction learning, as the latter has usually been found to leave outcome-specific information relatively intact. Thus, the present study reveals that a better understanding of the mechanisms supporting reversal training requires assessing the impact that this training exerts on the content of learning rather than performance per se .
Role Played by the Passage of Time in Reversal Learning
Goarin, Estelle H. F.; Lingawi, Nura W.; Laurent, Vincent
2018-01-01
Reversal learning is thought to involve an extinction-like process that inhibits the expression of the initial learning. However, behavioral evidence for this inhibition remains difficult to interpret as various procedures have been employed to study reversal learning. Here, we used a discrimination task in rats to examine whether the inhibition produced by reversal learning is as sensitive to the passage of time as the inhibition produced by extinction. Experiment 1 showed that when tested immediately after reversal training, rats were able to use the reversed contingencies to solve the discrimination task in an outcome-specific manner. This ability to use outcome-specific information was lost when a delay was inserted between reversal training and test. However, interpretation of these data was made difficult by a potential floor effect. This concern was addressed in Experiment 2 in which it was confirmed that the passage of time impaired the ability of the rats to use the reversed contingencies in an outcome-specific manner to solve the task. Further, it revealed that the delay between initial learning and test was not responsible for this impairment. Additional work demonstrated that solving the discrimination task was unaffected by Pavlovian extinction but that the discriminative stimuli were able to block conditioning to a novel stimulus, suggesting that Pavlovian processes were likely to contribute to solving the discrimination. We therefore concluded that the expression of reversal and extinction learning do share the same sensitivity to the effect of time. However, this sensitivity was most obvious when we assessed outcome-specific information following reversal learning. This suggests that the processes involved in reversal learning are somehow distinct from those underlying extinction learning, as the latter has usually been found to leave outcome-specific information relatively intact. Thus, the present study reveals that a better understanding of the mechanisms supporting reversal training requires assessing the impact that this training exerts on the content of learning rather than performance per se. PMID:29740293
A fluorescent immunoassay for the determination of procalcitonin and C-reactive protein
NASA Astrophysics Data System (ADS)
Baldini, F.; Bolzoni, L.; Giannetti, A.; Porro, G.; Senesi, F.; Trono, C.
2009-05-01
The discrimination of viral and bacterial sepsis is an important issue in intensive care patients. For this purpose, the simultaneous measurements of different analytes such as C-reactive protein (CRP), procalcitonin (PCT), myeloperoxidase, interleukines and neopterin, are necessary. A novel optical platform was designed and realised for the implementation of fluorescence-based immunoassays. The core of the optical platform is a plastic biochip, formed by a series of microchannels each of them devoted to the determination of a single analyte. Sandwich assays for CRP and PCT spiked in serum were performed in order to demonstrate the reliability of a multi-array device.
Combined Raman spectroscopy and autofluoresence imaging method for in vivo skin tumor diagnosis
NASA Astrophysics Data System (ADS)
Zakharov, V. P.; Bratchenko, I. A.; Myakinin, O. O.; Artemyev, D. N.; Khristoforova, Y. A.; Kozlov, S. V.; Moryatov, A. A.
2014-09-01
The fluorescence and Raman spectroscopy (RS) combined method of in vivo detection of malignant human skin cancer was demonstrated. The fluorescence analysis was used for detection of abnormalities during fast scanning of large tissue areas. In suspected cases of malignancy the Raman spectrum analysis of biological tissue was performed to determine the type of neoplasm. A special RS phase method was proposed for in vivo identification of skin tumor. Quadratic Discriminant Analysis was used for tumor type classification on phase planes. It was shown that the application of phase method provides a diagnosis of malignant melanoma with a sensitivity of 89% and a specificity of 87%.
Discrimination of normal and colorectal cancer using Raman spectroscopy and fluorescence
NASA Astrophysics Data System (ADS)
Li, Xiaozhou; Wang, Deli; Wang, Yue
2007-07-01
Laser-induced fluorescence spectroscopy (LIF) and Raman spectrum of serum for diagnosis of colon cancer and rectum cancer were investigated in this paper. The aim of this study was that using Raman spectrum and LIF analysis the serum of colon cancer and rectum cancer for found the difference compared to normal, the difference was found. For example: the intensity and red shift both different In this paper we investigated 82 colon cancers, 69 rectum cancers and obtained 80.7%, 82.5% accuracy to rectum cancer and colon cancer separately compared to clinical diagnostic. It is exploring that use Raman spectrum and LIF to detection of cancer.
NASA Astrophysics Data System (ADS)
Yi, Longtao; Liu, Zhiguo; Wang, Kai; Chen, Man; Peng, Shiqi; Zhao, Weigang; He, Jialin; Zhao, Guangcui
2015-03-01
A new method is presented to subtract the background from the energy dispersive X-ray fluorescence (EDXRF) spectrum using a cubic spline interpolation. To accurately obtain interpolation nodes, a smooth fitting and a set of discriminant formulations were adopted. From these interpolation nodes, the background is estimated by a calculated cubic spline function. The method has been tested on spectra measured from a coin and an oil painting using a confocal MXRF setup. In addition, the method has been tested on an existing sample spectrum. The result confirms that the method can properly subtract the background.
Singlet oxygen-sensitized delayed fluorescence of common water-soluble photosensitizers.
Scholz, Marek; Dědic, Roman; Breitenbach, Thomas; Hála, Jan
2013-10-01
Six common water-soluble singlet oxygen ((1)O2) photosensitizers - 5,10,15,20-tetrakis(1-methyl-4-pyridinio) porphine (TMPyP), meso-tetrakis(4-sulfonathophenyl)porphine (TPPS4), Al(III) phthalocyanine chloride tetrasulfonic acid (AlPcS4), eosin Y, rose bengal, and methylene blue - were investigated in terms of their ability to produce delayed fluorescence (DF) in solutions at room temperature. All the photosensitizers dissolved in air-saturated phosphate buffered saline (PBS, pH 7.4) exhibit easily detectable DF, which can be nearly completely quenched by 10 mM NaN3, a specific (1)O2 quencher. The DF kinetics has a biexponential rise-decay character in a microsecond time domain. Therefore, we propose that singlet oxygen-sensitized delayed fluorescence (SOSDF), where the triplet state of a photosensitizer reacts with (1)O2 giving rise to an excited singlet state of the photosensitizer, is the prevailing mechanism. It was confirmed by additional evidence, such as a monoexponential decay of triplet-triplet transient absorption kinetics, dependence of SOSDF kinetics on oxygen concentration, absence of SOSDF in a nitrogen-saturated sample, or the effect of isotopic exchange H2O-D2O. Eosin Y and AlPcS4 show the largest SOSDF quantum yield among the selected photosensitizers, whereas rose bengal possesses the highest ratio of SOSDF intensity to prompt fluorescence intensity. The rate constant for the reaction of triplet state with (1)O2 giving rise to the excited singlet state of photosensitizer was estimated to be ~/>1 × 10(9) M(-1) s(-1). SOSDF kinetics contains information about both triplet and (1)O2 lifetimes and concentrations, which makes it a very useful alternative tool for monitoring photosensitizing and (1)O2 quenching processes, allowing its detection in the visible spectral region, utilizing the photosensitizer itself as a (1)O2 probe. Under our experimental conditions, SOSDF was up to three orders of magnitude more intense than the infrared (1)O2 phosphorescence and by far the most important pathway of DF. SOSDF was also detected in a suspension of 3T3 mouse fibroblast cells, which underlines the importance of SOSDF and its relevance for biological systems.
NASA Astrophysics Data System (ADS)
Brainard, George C.; Coyle, William; Ayers, Melissa; Kemp, John; Warfield, Benjamin; Maida, James; Bowen, Charles; Bernecker, Craig; Lockley, Steven W.; Hanifin, John P.
2013-11-01
The International Space Station (ISS) uses General Luminaire Assemblies (GLAs) that house fluorescent lamps for illuminating the astronauts' working and living environments. Solid-state light emitting diodes (LEDs) are attractive candidates for replacing the GLAs on the ISS. The advantages of LEDs over conventional fluorescent light sources include lower up-mass, power consumption and heat generation, as well as fewer toxic materials, greater resistance to damage and long lamp life. A prototype Solid-State Lighting Assembly (SSLA) was developed and successfully installed on the ISS. The broad aim of the ongoing work is to test light emitted by prototype SSLAs for supporting astronaut vision and assessing neuroendocrine, circadian, neurobehavioral and sleep effects. Three completed ground-based studies are presented here including experiments on visual performance, color discrimination, and acute plasma melatonin suppression in cohorts of healthy, human subjects under different SSLA light exposure conditions within a high-fidelity replica of the ISS Crew Quarters (CQ). All visual tests were done under indirect daylight at 201 lx, fluorescent room light at 531 lx and 4870 K SSLA light in the CQ at 1266 lx. Visual performance was assessed with numerical verification tests (NVT). NVT data show that there are no significant differences in score (F=0.73, p=0.48) or time (F=0.14, p=0.87) for subjects performing five contrast tests (10%-100%). Color discrimination was assessed with Farnsworth-Munsell 100 Hue tests (FM-100). The FM-100 data showed no significant differences (F=0.01, p=0.99) in color discrimination for indirect daylight, fluorescent room light and 4870 K SSLA light in the CQ. Plasma melatonin suppression data show that there are significant differences (F=29.61, p<0.0001) across the percent change scores of plasma melatonin for five corneal irradiances, ranging from 0 to 405 μW/cm2 of 4870 K SSLA light in the CQ (0-1270 lx). Risk factors for the health and safety of astronauts include disturbed circadian rhythms and altered sleep-wake patterns. These studies will help determine if SSLA lighting can be used both to support astronaut vision and serve as an in-flight countermeasure for circadian desynchrony, sleep disruption and cognitive performance deficits on the ISS.
Functional Relationships for Investigating Cognitive Processes
Wright, Anthony A.
2013-01-01
Functional relationships (from systematic manipulation of critical variables) are advocated for revealing fundamental processes of (comparative) cognition—through examples from my work in psychophysics, learning, and memory. Functional relationships for pigeon wavelength (hue) discrimination revealed best discrimination at the spectral points of hue transition for pigeons—a correspondence (i.e., functional relationship) similar to that for humans. Functional relationships for learning revealed: Item-specific or relational learning in matching to sample as a function of the pigeons’ sample-response requirement, and same/different abstract-concept learning as a function of the training set size for rhesus monkeys, capuchin monkeys, and pigeons. Functional relationships for visual memory revealed serial position functions (a 1st order functional relationship) that changed systematically with retention delay (a 2nd order relationship) for pigeons, capuchin monkeys, rhesus monkeys, and humans. Functional relationships for rhesus-monkey auditory memory also revealed systematic changes in serial position functions with delay, but these changes were opposite to those for visual memory. Functional relationships for proactive interference revealed interference that varied as a function of a ratio of delay times. Functional relationships for change detection memory revealed (qualitative) similarities and (quantitative) differences in human and monkey visual short term memory as a function of the number of memory items. It is concluded that these findings were made possible by varying critical variables over a substantial portion of the manipulable range to generate functions and derive relationships. PMID:23174335
NASA Technical Reports Server (NTRS)
Feher, Kamilo
1993-01-01
The performance and implementation complexity of coherent and of noncoherent QPSK and GMSK modulation/demodulation techniques in a complex mobile satellite systems environment, including large Doppler shift, delay spread, and low C/I, are compared. We demonstrate that for large f(sub d)T(sub b) products, where f(sub d) is the Doppler shift and T(sub b) is the bit duration, noncoherent (discriminator detector or differential demodulation) systems have a lower BER floor than their coherent counterparts. For significant delay spreads, e.g., tau(sub rms) greater than 0.4 T(sub b), and low C/I, coherent systems outperform noncoherent systems. However, the synchronization time of coherent systems is longer than that of noncoherent systems. Spectral efficiency, overall capacity, and related hardware complexity issues of these systems are also analyzed. We demonstrate that coherent systems have a simpler overall architecture (IF filter implementation-cost versus carrier recovery) and are more robust in an RF frequency drift environment. Additionally, the prediction tools, computer simulations, and analysis of coherent systems is simpler. The threshold or capture effect in low C/I interference environment is critical for noncoherent discriminator based systems. We conclude with a comparison of hardware architectures of coherent and of noncoherent systems, including recent trends in commercial VLSI technology and direct baseband to RF transmit, RF to baseband (0-IF) receiver implementation strategies.
NASA Astrophysics Data System (ADS)
Feher, Kamilo
The performance and implementation complexity of coherent and of noncoherent QPSK and GMSK modulation/demodulation techniques in a complex mobile satellite systems environment, including large Doppler shift, delay spread, and low C/I, are compared. We demonstrate that for large f(sub d)T(sub b) products, where f(sub d) is the Doppler shift and T(sub b) is the bit duration, noncoherent (discriminator detector or differential demodulation) systems have a lower BER floor than their coherent counterparts. For significant delay spreads, e.g., tau(sub rms) greater than 0.4 T(sub b), and low C/I, coherent systems outperform noncoherent systems. However, the synchronization time of coherent systems is longer than that of noncoherent systems. Spectral efficiency, overall capacity, and related hardware complexity issues of these systems are also analyzed. We demonstrate that coherent systems have a simpler overall architecture (IF filter implementation-cost versus carrier recovery) and are more robust in an RF frequency drift environment. Additionally, the prediction tools, computer simulations, and analysis of coherent systems is simpler. The threshold or capture effect in low C/I interference environment is critical for noncoherent discriminator based systems. We conclude with a comparison of hardware architectures of coherent and of noncoherent systems, including recent trends in commercial VLSI technology and direct baseband to RF transmit, RF to baseband (0-IF) receiver implementation strategies.
Thiemann-Bourque, Kathy S; Brady, Nancy C; Fleming, Kandace K
2012-05-01
Children with autism are often described as having deficient play skills, particularly symbolic play. We compared the play of 35 children with autism to 38 children with other developmental delays. All children were preschool-age and produced less than 20 different words. Results indicated no significant differences across the two groups in their play. Children with autism engaged in more conventional play, that is, putting objects together according to how the toys were constructed (e.g., pieces in a puzzle, lid on a teapot). Results also indicated high correlations between play, language, and cognitive measures. Findings indicate that play relates to language and cognitive levels yet may not discriminate children with autism and children with other developmental delays early in their development.
Brady, Nancy C.; Fleming, Kandace K.
2011-01-01
Children with autism are often described as having deficient play skills, particularly symbolic play. We compared the play of 35 children with autism to 38 children with other developmental delays. All children were preschool-age and produced less than 20 different words. Results indicated no significant differences across the two groups in their play. Children with autism engaged in more conventional play, that is, putting objects together according to how the toys were constructed (e.g., pieces in a puzzle, lid on a teapot). Results also indicated high correlations between play, language, and cognitive measures. Findings indicate that play relates to language and cognitive levels yet may not discriminate children with autism and children with other developmental delays early in their development. PMID:21720725
Nganvongpanit, Korakot; Buddhachat, Kittisak; Brown, Janine L; Klinhom, Sarisa; Pitakarnnop, Tanita; Mahakkanukrauh, Pasuk
2016-09-01
Sex assignment of human remains is a crucial step in forensic anthropological studies. The aim of this study was to examine elemental differences between male and female bones using X-ray fluorescence (XRF) and determine if elemental profiling could be used for sex discrimination. Cranium, humerus, and os coxae of 60 skeletons (30 male, 30 female) from the Chiang Mai University Skeletal Collection were scanned by XRF and differences in elemental profiles between male and female bones determined using discriminant analysis. In the cranium, three elements (S, Ca, Pb) were significantly higher in males and five elements (Si, Mn, Fe, Zn, Ag) plus light elements (atomic number lower than 12) were higher in females. In humerus and os coxae, nine elements were significantly higher in male and one element was higher in female samples. The accuracy rate for sex estimation was 60, 63, and 61 % for cranium, humerus, and os coxae, respectively, and 67 % when data for all three bones were combined. We conclude that there are sex differences in bone elemental profiles; however, the accuracy of XRF analyses for discriminating between male and female samples was low compared to standard morphometric and molecular methods. XRF could be used on small samples that cannot be sexed by traditional morphological methods, but more work is needed to increase the power of this technique for gender assignment.
Durakli Velioglu, Serap; Ercioglu, Elif; Boyaci, Ismail Hakki
2017-05-01
This research paper describes the potential of synchronous fluorescence (SF) spectroscopy for authentication of buffalo milk, a favourable raw material in the production of some premium dairy products. Buffalo milk is subjected to fraudulent activities like many other high priced foodstuffs. The current methods widely used for the detection of adulteration of buffalo milk have various disadvantages making them unattractive for routine analysis. Thus, the aim of the present study was to assess the potential of SF spectroscopy in combination with multivariate methods for rapid discrimination between buffalo and cow milk and detection of the adulteration of buffalo milk with cow milk. SF spectra of cow and buffalo milk samples were recorded between 400-550 nm excitation range with Δλ of 10-100 nm, in steps of 10 nm. The data obtained for ∆λ = 10 nm were utilised to classify the samples using principal component analysis (PCA), and detect the adulteration level of buffalo milk with cow milk using partial least square (PLS) methods. Successful discrimination of samples and detection of adulteration of buffalo milk with limit of detection value (LOD) of 6% are achieved with the models having root mean square error of calibration (RMSEC) and the root mean square error of cross-validation (RMSECV) and root mean square error of prediction (RMSEP) values of 2, 7, and 4%, respectively. The results reveal the potential of SF spectroscopy for rapid authentication of buffalo milk.
Ikeura, Tsukasa; Takaoka, Makoto; Uchida, Kazushige; Shimatani, Masaaki; Miyoshi, Hideaki; Kato, Kota; Ohe, Chisato; Uemura, Yoshiko; Kaibori, Masaki; Kwon, A-Hon; Okazaki, Kazuichi
2015-01-01
EUS-guided FNA (EUS-FNA) has been increasingly performed to obtain specimens for the pathological evaluation of patients with GI and pancreaticobiliary masses as well as lymphadenopathies of unknown origin. Photodynamic diagnosis by using 5-aminolebulinic acid (ALA) has been reported to be useful for enabling the visual differentiation between malignant and normal tissue in various cancers. To evaluate the diagnostic accuracy of fluorescence cytology with ALA in EUS-FNA. A prospective study. A single center. A total of 28 consecutive patients who underwent EUS-FNA for the pathological diagnosis of a pancreaticobiliary mass lesion or intra-abdominal lymphadenopathy of unknown origin. Patients were orally administered ALA 3 to 6 hours before EUS-FNA. The sample was obtained via EUS-FNA for fluorescence cytology and conventional cytology. A single gastroenterologist performed the fluorescence cytology by using fluorescence microscopy after the procedure, independently of the conventional cytology by pathologists. The accuracy of fluorescence cytology with ALA in the differentiation between benign and malignant lesions by comparing the results of fluorescence cytology with the final diagnosis. Of the 28 patients included in the study, 22 were considered as having malignant lesions and 6 patients as having benign lesions. Fluorescence cytology could correctly discriminate between benign and malignant lesions in all patients. Therefore, both the sensitivity and specificity of fluorescence cytology were 100% in our study. Fluorescence cytology was performed by only 1 gastroenterologist with a small number of patients. Fluorescence cytology with ALA in EUS-FNA may be an effective and simple method for differentiating between benign and malignant lesions. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Spectroscopic neutron detection using composite scintillators
NASA Astrophysics Data System (ADS)
Jovanovic, I.; Foster, A.; Kukharev, V.; Mayer, M.; Meddeb, A.; Nattress, J.; Ounaies, Z.; Trivelpiece, C.
2016-09-01
Shielded special nuclear material (SNM), especially highly enriched uranium, is exceptionally difficult to detect without the use of active interrogation (AI). We are investigating the potential use of low-dose active interrogation to realize simultaneous high-contrast imaging and photofission of SNM using energetic gamma-rays produced by low-energy nuclear reactions, such as 11B(d,nγ)12C and 12C(p,p‧)12C. Neutrons produced via fission are one reliable signature of the presence of SNM and are usually identified by their unique timing characteristics, such as the delayed neutron die-away. Fast neutron spectroscopy may provide additional useful discriminating characteristics for SNM detection. Spectroscopic measurements can be conducted by recoil-based or thermalization and capture-gated detectors; the latter may offer unique advantages since they facilitate low-statistics and event-by-event neutron energy measurements without spectrum unfolding. We describe the results of the development and characterization of a new type of capture-gated spectroscopic neutron detector based on a composite of scintillating polyvinyltoluene and lithium-doped scintillating glass in the form of millimeter-thick rods. The detector achieves >108 neutron-gamma discrimination resulting from its geometric properties and material selection. The design facilitates simultaneous pulse shape and pulse height discrimination, despite the fact that no materials intrinsically capable of pulse shape discrimination have been used to construct the detector. Accurate single-event measurements of neutron energy may be possible even when the energy is relatively low, such as with delayed fission neutrons. Simulation and preliminary measurements using the new composite detector are described, including those conducted using radioisotope sources and the low-dose active interrogation system based on low-energy nuclear reactions.
2018-01-01
Many individuals with posttraumatic stress disorder (PTSD) report experiencing frequent intrusive memories of the original traumatic event (e.g., flashbacks). These memories can be triggered by situations or stimuli that reflect aspects of the trauma and may reflect basic processes in learning and memory, such as generalization. It is possible that, through increased generalization, non-threatening stimuli that once evoked normal memories become associated with traumatic memories. Previous research has reported increased generalization in PTSD, but the role of visual discrimination processes has not been examined. To investigate visual discrimination in PTSD, 143 participants (Veterans and civilians) self-assessed for symptom severity were grouped according to the presence of severe PTSD symptoms (PTSS) vs. few/no symptoms (noPTSS). Participants were given a visual match-to-sample pattern separation task that varied trials by spatial separation (Low, Medium, High) and temporal delays (5, 10, 20, 30 s). Unexpectedly, the PTSS group demonstrated better discrimination performance than the noPTSS group at the most difficult spatial trials (Low spatial separation). Further assessment of accuracy and reaction time using diffusion drift modeling indicated that the better performance by the PTSS group on the hardest trials was not explained by slower reaction times, but rather a faster accumulation of evidence during decision making in conjunction with a reduced threshold, indicating a tendency in the PTSS group to decide quickly rather than waiting for additional evidence to support the decision. This result supports the need for future studies examining the precise role of discrimination and generalization in PTSD, and how these cognitive processes might contribute to expression and maintenance of PTSD symptoms. PMID:29736339
In-Vivo Fluorescence Spectroscopy Of Normal And Atherosclerotic Arteries
NASA Astrophysics Data System (ADS)
Deckelbaum, Lawrence I.; Sarembock, Ian J.; Stetz, Mark L.; O'Brien, Kenneth M.; Cutruzzola, Francis W.; Gmitro, Arthur F.; Ezekowitz, Michael D.
1988-06-01
Laser-induced fluorescence spectroscopy can discriminate atherosclerotic from normal arteries in-vitro and may thus potentially guide laser angioplasty. To evaluate the feasibility of laser-induced fluorescence spectroscopy in a living blood-filled arterial system we performed fiberoptic laser-induced fluorescence spectroscopy in a rabbit model of focal femoral atherosclerosis. A laser-induced fluorescence spectroscopy score was derived from stepwise linear regression analysis of in-vitro spectra to distinguish normal aorta (score>0) from atherosclerotic femoral artery (score<0). A 400 u silica fiber, coupled to a helium cadmium laser and optical multichannel analyzer, was inserted through a 5F catheter to induce and record in-vivo fluorescence from femoral and aortoiliac arteries. Arterial spectra could be recorded in all animals (n=10: 5 occlusions, 5 stenoses). Blood spectra were of low intensity and were easily distinguished from arterial spectra. The scores (mean ± SEM) for the in-vivo spectra were -0.69 +/- 0.29 for artherosclerotic femoral, and +0.54 ±. 0.15 for normal aorta (p<.01 p=NS compared to in-vitro spectra). In-vitro, a fiber tip to tissue distance <50 u was necessary for adequate arterial LIFS in blood. At larger distances low intensity blood spectra were recorded (1/20 the intensity of tissue spectra). Thus, fiberoptic laser-induced fluorescence spectroscopy can be sucessfully performed in a blood filled artery provided the fiber tip is approximated to the tissue.
Laser-induced fluorescence in the detection of esophageal carcinoma
NASA Astrophysics Data System (ADS)
Wang, Kenneth K.; Gutta, Kumar; Laukka, Mark A.; Densmore, John
1995-01-01
Laser induced fluorescence (LIF) is a technique which can perform an 'optical biopsy' of gastrointestinal mucosa. LIF was performed in resected specimens using a pulsed N2-laser coupled fiberoptically to a probe. Fluorescence was measured using a 0.2 meter spectroscope with an intensified photodiode array. Measurements were made on fresh (<30 minutes after resection) esophageal specimens containing normal mucosa, Barrett's esophagus, and adenocarcinoma. Each tissue section was examined using an optical probe consisting of a central fiber for delivering the excitation energy and a 6 fiber bundle surrounding the central fiber for detection of the fluorescence. An excitation wavelength of 337 nm was used which generated 3-ns pulses while fluorescence intensities were acquired from 300-800 nm. Spectra were obtained from each section in a standardized fashion and background spectra subtracted. Fluorescence readings were taken from 54 normal esophageal sections and 32 sections of adenocarcinoma. A fluorescence index obtained from the tumor sections was 0.68+/- 0.01 compared with 0.51+/- 0.01 for the normal sections (p<0.001). Using a discriminant value of 0.65, this technique had a sensitivity of 81% and a specificity of 100% for detection of malignant tissue. The positive predictive value was 100% and the negative predictive value was 90% for an overall accuracy of 93%. LIF is a promising technique which has the capability of distinguishing normal versus malignant tissue in the esophagus with good accuracy.
Airborne particle characterization by spatial scattering and fluorescence
NASA Astrophysics Data System (ADS)
Barton, John; Hirst, Edwin; Kaye, Paul; Saunders, Spencer; Clark, Don
1999-11-01
Several workers have reported the development of systems which allow the measurement of intrinsic fluorescence from particles irradiated with ultra-violet radiation. The fluorescence data are frequently recorded in conjunction with other parameters such as particle size, measured either as a function of optical scatter or as an aerodynamic size. The motivation for this work has been principally the detection of bioaerosols within an ambient environment. Previous work by the authors has shown that an analysis of the scattering profile of a particle, i.e.: the spatial distribution of light scattered by the particle carried in a sample air-stream, can provide an effective means of particle characterization and classification in terms of both size and shape parameters. Current work is aimed at the simultaneous recording of both spatial scattering and fluorescence data from individual particles with a view to substantially enhanced discrimination of biological aerosols. A prototype instrument has recently been completed which employs a cw 266 nm laser source to produce both elastic (spatial scattering) and inelastic (fluorescence) signals from individual airborne particles. The instrument incorporates a custom designed high-gain multi- pixel hybrid photodiode (HPD) to record the spatial scattering data and a single photomultiplier to record total fluorescence from the illuminated particle. Recorded data are processed to allow the classification of airborne particles on the basis of size, shape, and fluorescence for both biological and non- biological aerosols.
Sahoo, Harekrushna; Hennig, Andreas; Florea, Mara; Roth, Doris; Enderle, Thilo; Nau, Werner M
2007-12-26
The collision-induced fluorescence quenching of a 2,3-diazabicyclo[2.2.2]oct-2-ene-labeled asparagine (Dbo) by hydrogen atom abstraction from the tyrosine residue in peptide substrates was introduced as a single-labeling strategy to assay the activity of tyrosine kinases and phosphatases. The assays were tested for 12 different combinations of Dbo-labeled substrates and with the enzymes p60c-Src Src kinase, EGFR kinase, YOP protein tyrosine phosphatase, as well as acid and alkaline phosphatases, thereby demonstrating a broad application potential. The steady-state fluorescence changed by a factor of up to 7 in the course of the enzymatic reaction, which allowed for a sufficient sensitivity of continuous monitoring in steady-state experiments. The fluorescence lifetimes (and intensities) were found to be rather constant for the phosphotyrosine peptides (ca. 300 ns in aerated water), while those of the unphosphorylated peptides were as short as 40 ns (at pH 7) and 7 ns (at pH 13) as a result of intramolecular quenching. Owing to the exceptionally long fluorescence lifetime of Dbo, the assays were alternatively performed by using nanosecond time-resolved fluorescence (Nano-TRF) detection, which leads to an improved discrimination of background fluorescence and an increased sensitivity. The potential for inhibitor screening was demonstrated through the inhibition of acid and alkaline phosphatases by molybdate.
Chung, Kyeongwoon; Yang, Da Seul; Jung, Jaehun; Seo, Deokwon; Kwon, Min Sang; Kim, Jinsang
2016-10-06
Differentiation of solvents having similar physicochemical properties, such as ethanol and methanol, is an important issue of interest. However, without performing chemical analyses, discrimination between methanol and ethanol is highly challenging due to their similarity in chemical structure as well as properties. Here, we present a novel type of alcohol and water sensor based on the subtle differences in interaction among solvent analytes, fluorescent organic molecules, and a mesoporous silica gel substrate. A gradual change in the chemical structure of the fluorescent diketopyrrolopyrrole (DPP) derivatives alters their interaction with the substrate and solvent analyte, which creates a distinct intermolecular aggregation of the DPP derivatives on the silica gel substrate depending on the solvent environment and produces a change in the fluorescence color and intensity as a sensory signal. The devised sensor device, which is fabricated with simple drop-casting of the DPP derivative solutions onto a silica gel substrate, exhibited a completely reversible fluorescence signal change with large fluorescence signal contrast, which allows selective solvent detection by simple optical observation with the naked eye under UV light. Superior selectivity of the alcohol and water sensor system, which can clearly distinguish among ethanol, methanol, ethylene glycol, and water, is demonstrated.
Novel DNA probes with low background and high hybridization-triggered fluorescence.
Lukhtanov, Eugeny A; Lokhov, Sergey G; Gorn, Vladimir V; Podyminogin, Mikhail A; Mahoney, Walt
2007-01-01
Novel fluorogenic DNA probes are described. The probes (called Pleiades) have a minor groove binder (MGB) and a fluorophore at the 5'-end and a non-fluorescent quencher at the 3'-end of the DNA sequence. This configuration provides surprisingly low background and high hybridization-triggered fluorescence. Here, we comparatively study the performance of such probes, MGB-Eclipse probes, and molecular beacons. Unlike the other two probe formats, the Pleiades probes have low, temperature-independent background fluorescence and excellent signal-to-background ratios. The probes possess good mismatch discrimination ability and high rates of hybridization. Based on the analysis of fluorescence and absorption spectra we propose a mechanism of action for the Pleiades probes. First, hydrophobic interactions between the quencher and the MGB bring the ends of the probe and, therefore, the fluorophore and the quencher in close proximity. Second, the MGB interacts with the fluorophore and independent of the quencher is able to provide a modest (2-4-fold) quenching effect. Joint action of the MGB and the quencher is the basis for the unique quenching mechanism. The fluorescence is efficiently restored upon binding of the probe to target sequence due to a disruption in the MGB-quencher interaction and concealment of the MGB moiety inside the minor groove.
Novel DNA probes with low background and high hybridization-triggered fluorescence
Lukhtanov, Eugeny A.; Lokhov, Sergey G.; Gorn, Vladimir V.; Podyminogin, Mikhail A.; Mahoney, Walt
2007-01-01
Novel fluorogenic DNA probes are described. The probes (called Pleiades) have a minor groove binder (MGB) and a fluorophore at the 5′-end and a non-fluorescent quencher at the 3′-end of the DNA sequence. This configuration provides surprisingly low background and high hybridization-triggered fluorescence. Here, we comparatively study the performance of such probes, MGB-Eclipse probes, and molecular beacons. Unlike the other two probe formats, the Pleiades probes have low, temperature-independent background fluorescence and excellent signal-to-background ratios. The probes possess good mismatch discrimination ability and high rates of hybridization. Based on the analysis of fluorescence and absorption spectra we propose a mechanism of action for the Pleiades probes. First, hydrophobic interactions between the quencher and the MGB bring the ends of the probe and, therefore, the fluorophore and the quencher in close proximity. Second, the MGB interacts with the fluorophore and independent of the quencher is able to provide a modest (2–4-fold) quenching effect. Joint action of the MGB and the quencher is the basis for the unique quenching mechanism. The fluorescence is efficiently restored upon binding of the probe to target sequence due to a disruption in the MGB–quencher interaction and concealment of the MGB moiety inside the minor groove. PMID:17259212
Uncovering of melanin fluorescence in human skin tissue
NASA Astrophysics Data System (ADS)
Scholz, Matthias; Stankovic, Goran; Seewald, Gunter; Leupold, Dieter
2007-07-01
Due to its extremely low fluorescence quantum yield, in the conventionally (one-photon) excited autofluorescence of skin tissue, melanin fluorescence is masked by several other endogenous and possibly also exogenous fluorophores (e.g. NADH, FAD, Porphyrins). A first step to enhance the melanin contribution had been realized by two-photon fs-pulse excitation in the red/near IR, based on the fact that melanin can be excited by stepwise two-photon absorption, whereas all other fluorophores in this spectral region allow only simultaneous two-photon excitation. Now, the next and decisive step has been realized: Using an extremely sensitive detection system, for the first time twophoton fluorescence of skin tissue excited with pulses in the ns-range could be measured. The motivation for this step was based on the fact that the population density of the fluorescent level resulting from a stepwise excitation has a different dependence of the pulse duration than that from a simultaneous excitation (Δt2 vs. Δt). Due to this strong discrimination between the fluorophores, practically pure melanin fluorescence can be obtained. Examples for in-vivo, ex-vivo as well as paraffin embedded skin tissue will be shown. The content of information with respect to early diagnosis of skin deseases will be discussed.
Pottier, Fabien; Michelin, Anne; Andraud, Christine; Goubard, Fabrice; Lavédrine, Bertrand
2018-04-01
Ultraviolet visible (UV-Vis) fluorescence spectroscopy is widely used to study polychrome objects and can help to identify the nature of certain materials when they present specific fluorescent properties. However, given the complexity of the stratified and heterogeneous materials under study, the characterization of an intrinsic fluorescence related to a given constituent (a pigment or a binder composing a paint layer for example) is not straightforward, and the recorded raw data need to be corrected for a number of effects that can influence the detected spectral distribution. The application of standard correction procedures to experimental fluorescence data gathered on the polychromatic surface of the Codex Borbonicus, a 16th-century Aztec manuscript, is described. The results are confronted to an alternate new methodology that is based on the hypothesis of transparent non-scattering paint layers. This second approach allows to establish more clearly the material origin of the detected emission and to discriminate apparent fluorescence (emitted by the substrate and transmitted through the paint layers) from actual intrinsic emission generated by the coloring materials under study. The results show that most of the various emission profiles detected in the paint layers of the manuscript actually originate from a unique fluorophore (composing the substrate) and should not be used to characterize the coloring materials.
A New Submersible Imaging-in-flow Instrument to Monitor Nano- and Microplankton: Imaging FlowCytobot
NASA Astrophysics Data System (ADS)
Olson, R. J.; Sosik, H. M.; Shalapyonok, A.
2004-12-01
Understanding of how coastal plankton communities are regulated has traditionally been limited by undersampling, but cabled observatories now provide opportunities to deploy submersible sensors that have high power and data transmission requirements. We have developed an in situ instrument to carry out high-resolution, long term monitoring of phytoplankton and microzooplankton in the size range 10 to100 micrometers, to be deployed at cabled research facilities such as the Martha's Vineyard Coastal Observatory (MVCO). The new instrument is designed to complement FlowCytobot, a submersible flow cytometer currently deployed at MVCO that uses fluorescence and light scattering signals from a laser beam to characterize the smallest phytoplankton cells (less than 10 micrometers). Imaging FlowCytobot uses a combination of flow cytometric and video technology to capture images of organisms for identification and to measure chlorophyll fluorescence associated with each image. Images will be classified using neural net software, while the measurements of chlorophyll fluorescence will allow us to discriminate heterotrophic from phototrophic cells. The new instrument, like the original FlowCytobot is autonomous but remotely programmable. It utilizes a computer controlled syringe pump and distribution valve that allows periodic anti-fouling treatment and analysis of standard beads. Samples are analyzed continuously (0.25 to 2.5 ml per min) and data is sent over a fiber optic link to a remote computer for analysis. Preliminary results indicate that we can detect cells as small as 5 micrometers and discriminate several taxa of diatoms and dinoflagellates.
Flow-Tagging Velocimetry for Hypersonic Flows Using Fluorescence of Nitric Oxide
NASA Technical Reports Server (NTRS)
Danehy, Paul M.; OByrne, Sean; Houwing, A. Frank P.; Fox, Jodie S.; Smith, Daniel R.
2003-01-01
We demonstrate a new variation of molecular-tagging velocimetry for hypersonic flows based on laser-induced fluorescence. A thin line of nitric-oxide molecules is excited with a laser beam and then, after a time delay, a fluorescence image of the displaced line is acquired. One component of velocity is determined from the time of flight. This method is applied to measure the velocity profile in a Mach 8.5 laminar, hypersonic boundary layer in the Australian National University s T2 free-piston shock tunnel. The single-shot velocity measurement uncertainty in the freestream was found to be 3.5%, based on 90% confidence. The method is also demonstrated in the separated flow region forward of a blunt fin attached to a flat plate in a Mach 7.4 flow produced by the Australian National University s T3 free-piston shock tunnel. The measurement uncertainty in the blunt fin experiment is approximately 30%, owing mainly to low fluorescence intensities, which could be improved significantly in future experiments. This velocimetry method is applicable to very high-speed flows that have low collisional quenching of the fluorescing species. It is particularly convenient in facilities where planar laser-induced fluorescence is already being performed.
Study on high power ultraviolet laser oil detection system
NASA Astrophysics Data System (ADS)
Jin, Qi; Cui, Zihao; Bi, Zongjie; Zhang, Yanchao; Tian, Zhaoshuo; Fu, Shiyou
2018-03-01
Laser Induce Fluorescence (LIF) is a widely used new telemetry technology. It obtains information about oil spill and oil film thickness by analyzing the characteristics of stimulated fluorescence and has an important application in the field of rapid analysis of water composition. A set of LIF detection system for marine oil pollution is designed in this paper, which uses 355nm high-energy pulsed laser as the excitation light source. A high-sensitivity image intensifier is used in the detector. The upper machine sends a digital signal through a serial port to achieve nanoseconds range-gated width control for image intensifier. The target fluorescence spectrum image is displayed on the image intensifier by adjusting the delay time and the width of the pulse signal. The spectral image is coupled to CCD by lens imaging to achieve spectral display and data analysis function by computer. The system is used to detect the surface of the floating oil film in the distance of 25m to obtain the fluorescence spectra of different oil products respectively. The fluorescence spectra of oil products are obvious. The experimental results show that the system can realize high-precision long-range fluorescence detection and reflect the fluorescence characteristics of the target accurately, with broad application prospects in marine oil pollution identification and oil film thickness detection.
2012-01-01
Background To assess the ability of fluorescence imaging to detect a dose response relationship between fluorosis severity and different levels of fluoride in water supplies compared to remote photographic scoring in selected populations participating in an observational, epidemiological survey in Chiang Mai, Thailand. Methods Subjects were male and female lifetime residents aged 8-13 years. For each child the fluoride content of cooking water samples (CWS) was assessed to create categorical intervals of water fluoride concentration. Fluorescence images were taken of the maxillary central incisors and analyzed for dental fluorosis using two different software techniques. Output metrics for the fluorescence imaging techniques were compared to TF scores from blinded photographic scores obtained from the survey. Results Data from 553 subjects were available. Both software analysis techniques demonstrated significant correlations with the photographic scores. The metrics for area effected by fluorosis and the overall fluorescence loss had the strongest association with the photographic TF score (Spearman’s rho 0.664 and 0.652 respectively). Both software techniques performed well for comparison of repeat fluorescence images with ICC values of 0.95 and 0.85 respectively. Conclusions This study supports the potential use of fluorescence imaging for the objective quantification of dental fluorosis. Fluorescence imaging was able to discriminate between populations with different fluoride exposures on a comparable level to remote photographic scoring with acceptable levels of repeatability. PMID:22908997
Song, Luna; Zhang, Yonghua; Li, Junling; Gao, Qiang; Qi, Honglan; Zhang, Chengxiao
2016-04-01
An enzyme-free signal amplification-based assay for DNA detection was developed using fluorescent hairpin DNA probes coupled with hybridization chain reaction (HCR). The hairpin DNAs were designed to contain abasic sites in the stem moiety. Non-covalent labeling of the hairpin DNAs was achieved when a fluorescent ligand was bound to the abasic sites through hydrogen bonding with the orphan cytosine present on the complementary strand, accompanied by quench of ligand fluorescence. As a result, the resultant probes, the complex formed between the hairpin DNA and ligand, showed almost no fluorescence. Upon hybridization with target DNA, the probe underwent a dehybridization of the stem moiety containing an abasic site. The release of ligand from the abasic site to the solution resulted in an effective fluorescent enhancement, which can be used as a signal. Compared with a sensing system without HCR, a 20-fold increase in the sensitivity was achieved using the sensing system with HCR. The fluorescent intensity of the sensing system increased with the increase in target DNA concentration from 0.5 nM to 100 nM. A single mismatched target ss-DNA could be effectively discriminated from complementary target DNA. Genotyping of a G/C single-nucleotide polymorphism of polymerase chain reaction (PCR) products was successfully demonstrated with the sensing system. Therefore, integrating HCR strategy with non-covalent labeling of fluorescent hairpin DNA probes provides a sensitive and cost-effective DNA assay. © The Author(s) 2016.
ALA-induced PpIX spectroscopy for brain tumor image-guided surgery
NASA Astrophysics Data System (ADS)
Valdes, Pablo A.; Leblond, Frederic; Kim, Anthony; Harris, Brent T.; Wilson, Brian C.; Paulsen, Keith D.; Roberts, David W.
2011-03-01
Maximizing the extent of brain tumor resection correlates with improved survival and quality of life outcomes in patients. Optimal surgical resection requires accurate discrimination between normal and abnormal, cancerous tissue. We present our recent experience using quantitative optical spectroscopy in 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence-guided resection. Exogenous administration of ALA leads to preferential accumulation in tumor tissue of the fluorescent compound, PpIX, which can be used for in vivo surgical guidance. Using the state of the art approach with a fluorescence surgical microscope, we have been able to visualize a subset of brain tumors, but the sensitivity and accuracy of fluorescence detection for tumor tissue with this system are low. To take full advantage of the biological selectivity of PpIX accumulation in brain tumors, we used a quantitative optical spectroscopy system for in vivo measurements of PpIX tissue concentrations. We have shown that, using our quantitative approach for determination of biomarker concentrations, ALA-induced PpIX fluorescence-guidance can achieve accuracies of greater than 90% for most tumor histologies. Here we show multivariate analysis of fluorescence and diffuse reflectance signals in brain tumors with comparable diagnostic performance to our previously reported quantitative approach. These results are promising, since they show that technological improvements in current fluorescence-guided surgical technologies and more biologically relevant approaches are required to take full advantage of fluorescent biomarkers, achieve better tumor identification, increase extent of resection, and subsequently, lead to improve survival and quality of life in patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mieno, H.; Kabe, R.; Allendorf, M. D.
Here, the first metal–organic framework exhibiting thermally activated delayed fluorescence (TADF) was developed. The zirconium-based framework (UiO-68-dpa) uses a newly designed linker composed of a terphenyl backbone, an electron-accepting carboxyl group, and an electron-donating diphenylamine and exhibits green TADF emission with a photoluminescence quantum yield of 30% and high thermal stability.
Using Carbon Nanotubes for Nanometer-Scale Energy Transfer Microscopy
NASA Astrophysics Data System (ADS)
Johnston, Jessica; Shafran, Eyal; Mangum, Ben; Mu, Chun; Gerton, Jordan
2009-10-01
We investigate optical energy transfer between fluorophores and carbon nanotubes (CNTs). CNTs are grown on Si-oxide wafers by chemical vapor deposition (CVD), lifted off substrates by atomic force microscope (AFM) tips via Van der Waals forces, then shortened by electrical pulses. The tip-attached CNTs are scanned over fluorescent CdSe-ZnS quantum dots (QDs) with sub-nm precision while recording the fluorescence rate. A novel photon counting technique enables us to produce 3D maps of the QD-CNT coupling, revealing nanoscale lateral and vertical features. All CNTs tested (>50) strongly quenched the QD fluorescence, apparently independent of chirality. In some data, a delay in the recovery of QD fluorescence following CNT-QD contact was observed, suggesting possible charge transfer in this system. In the future, we will perform time-resolved studies to quantify the rate of energy and charge transfer processes and study the possible differences in fluorescence quenching and nanotube-QD energy transfer when comparing single-walled (SW) versus multi-walled (MW) CNTs, attempting to grow substrates consisting primarily of SW or MWCNTs and characterizing the structure of tip-attached CNTs using optical spectroscopy.
Assessment of follicle viability using fluorescence microscopy before and after ovarian thawing.
Sofoudis, C; Zervomanolakis, I; Galani, I; Grigoriou, V; Botsis, D; Vlahos, N
2017-01-01
The incidence of young women diagnosed with cancer has been globally increasing. In many cases the surgical approach followed by chemotherapy, radiotherapy or hormonal therapy could lead to infertility or premature ovarian failure. Several options are available in order to preserve fertility and increase the future gestation rate. Among embryo cryopreservation and oocyte cryopreservation, ovarian tissue cryopreservation represents an ideal option, especially for premenopausal women and for those who cannot delay the start of chemotherapy. The purpose of this study was to examine the follicle viability using fluorescence microscope before and after ovarian thawing.
Integrated Optoelectronics for Parallel Microbioanalysis
NASA Technical Reports Server (NTRS)
Stirbl, Robert; Moynihan, Philip; Bearman, Gregory; Lane, Arthur
2003-01-01
Miniature, relatively inexpensive microbioanalytical systems ("laboratory-on-achip" devices) have been proposed for the detection of hazardous microbes and toxic chemicals. Each system of this type would include optoelectronic sensors and sensor-output-processing circuitry that would simultaneously look for the optical change, fluorescence, delayed fluorescence, or phosphorescence signatures from multiple redundant sites that have interacted with the test biomolecules in order to detect which one(s) was present in a given situation. These systems could be used in a variety of settings that could include doctors offices, hospitals, hazardous-material laboratories, biological-research laboratories, military operations, and chemical-processing plants.
Morell, Montse; Espargaro, Alba; Aviles, Francesc Xavier; Ventura, Salvador
2008-01-01
We present a high-throughput approach to study weak protein-protein interactions by coupling bimolecular fluorescent complementation (BiFC) to flow cytometry (FC). In BiFC, the interaction partners (bait and prey) are fused to two rationally designed fragments of a fluorescent protein, which recovers its function upon the binding of the interacting proteins. For weak protein-protein interactions, the detected fluorescence is proportional to the interaction strength, thereby allowing in vivo discrimination between closely related binders with different affinity for the bait protein. FC provides a method for high-speed multiparametric data acquisition and analysis; the assay is simple, thousands of cells can be analyzed in seconds and, if required, selected using fluorescence-activated cell sorting (FACS). The combination of both methods (BiFC-FC) provides a technically straightforward, fast and highly sensitive method to validate weak protein interactions and to screen and identify optimal ligands in biologically synthesized libraries. Once plasmids encoding the protein fusions have been obtained, the evaluation of a specific interaction, the generation of a library and selection of active partners using BiFC-FC can be accomplished in 5 weeks.
Identification of gram-negative and gram-positive bacteria by fluorescence studies
NASA Astrophysics Data System (ADS)
Demchak, Jonathan; Calabrese, Joseph; Tzolov, Marian
2011-03-01
Several type strains of bacteria including Vibrio fischeri, Azotobacter vinelandii, Enterobacter cloacae, and Corynebacterium xerosis, were cultured in the laboratory following standard diagnostic protocol based on their individual metabolic strategies. The bacterial cultures were not further treated and they were studied in their pristine state (pure culture - axenic). The fluorescent studies were applied using a continuous wave and a pulsed excitation light sources. Emission and excitation spectra were recorded for the continuous wave excitation and they all show similar spectral features with the exception of the gram positive bacteria showing vibronic structures. The vibrational modes involved in these vibronic bands have energy typical for carbon-carbon vibrations. The fluorescence is quenched in addition of water, even a very thin layer, which confirms that the observed spectral features originate from the outer parts of the bacteria. These results allow to conclude that the fluorescence spectroscopy can be used as a method for studying the membranes of the bacteria and eventually to discriminate between gram positive and gram negative bacteria. The pulsed experiments show that the fluorescence lifetime is in the sub-microsecond range. The results indicate that the observed spectra are superposition of the emission with different lifetimes.
Wan, Yi; Sun, Yan; Qi, Peng; Wang, Peng; Zhang, Dun
2014-05-15
Nanomaterial-based 'chemical nose' sensor with sufficient sensing specificity is a useful analytical tool for the detection of toxicologically important substances in complicated biological systems. A sensor array containing three quaternized magnetic nanoparticles (q-MNPs)-fluorescent polymer systems has been designed to identify and quantify bacteria. The bacterial cell membranes disrupt the q-MNP-fluorescent polymer, generating unique fluorescence response array. The response intensity of the array is dependent on the level of displacement determined by the relative q-MNP-fluorescent polymer binding strength and bacteria cells-MNP interaction. These characteristic responses show a highly repeatable bacteria cells and can be differentiated by linear discriminant analysis (LDA). Based on the array response matrix from LDA, our approach has been used to measure bacteria with an accuracy of 87.5% for 10(7) cfu mL(-1) within 20 min. Combined with UV-vis measurement, the method can be successfully performed to identify and detect eight different pathogen samples with an accuracy of 96.8%. The measurement system has a potential for further applications and provides a facile and simple method for the rapid analysis of protein, DNA, and pathogens. Copyright © 2013 Elsevier B.V. All rights reserved.
Monitoring biological aerosols using UV fluorescence
NASA Astrophysics Data System (ADS)
Eversole, Jay D.; Roselle, Dominick; Seaver, Mark E.
1999-01-01
An apparatus has been designed and constructed to continuously monitor the number density, size, and fluorescent emission of ambient aerosol particles. The application of fluorescence to biological particles suspended in the atmosphere requires laser excitation in the UV spectral region. In this study, a Nd:YAG laser is quadrupled to provide a 266 nm wavelength to excite emission from single micrometer-sized particles in air. Fluorescent emission is used to continuously identify aerosol particles of biological origin. For calibration, biological samples of Bacillus subtilis spores and vegetative cells, Esherichia coli, Bacillus thuringiensis and Erwinia herbicola vegetative cells were prepared as suspensions in water and nebulized to produce aerosols. Detection of single aerosol particles, provides elastic scattering response as well as fluorescent emission in two spectral bands simultaneously. Our efforts have focuses on empirical characterization of the emission and scattering characteristics of various bacterial samples to determine the feasibility of optical discrimination between different cell types. Preliminary spectroscopic evidence suggest that different samples can be distinguished as separate bio-aerosol groups. In addition to controlled sample results, we will also discuss the most recent result on the effectiveness of detection outdoor releases and variations in environmental backgrounds.
Sheaff, Chrystal N; Eastwood, Delyle; Wai, Chien M
2007-01-01
The detection of explosive material is at the forefront of current analytical problems. A detection method is desired that is not restricted to detecting only explosive materials, but is also capable of identifying the origin and type of explosive. It is essential that a detection method have the selectivity to distinguish among compounds in a mixture of explosives. The nitro compounds found in explosives have low fluorescent yields or are considered to be non-fluorescent; however, after reduction, the amino compounds exhibit relatively high fluorescence. We discuss how to increase selectivity of explosive detection using fluorescence; this includes synchronous luminescence and derivative spectroscopy with appropriate smoothing. By implementing synchronous luminescence and derivative spectroscopy, we were able to resolve the reduction products of one major TNT-based explosive compound, 2,4-diaminotoluene, and the reduction products of other minor TNT-based explosives in a mixture. We also report for the first time the quantum yields of these important compounds. Relative quantum yields are useful in establishing relative fluorescence intensities and are an important spectroscopic measurement of molecules. Our approach allows for rapid, sensitive, and selective detection with the discrimination necessary to distinguish among various explosives.
NASA Astrophysics Data System (ADS)
Hellebust, Anne; Rosbach, Kelsey; Wu, Jessica Keren; Nguyen, Jennifer; Gillenwater, Ann; Vigneswaran, Nadarajah; Richards-Kortum, Rebecca
2013-12-01
In this longitudinal study, a mouse model of 4-nitroquinoline 1-oxide chemically induced tongue carcinogenesis was used to assess the ability of optical imaging with exogenous and endogenous contrast to detect neoplastic lesions in a heterogeneous mucosal surface. Widefield autofluorescence and fluorescence images of intact 2-NBDG-stained and proflavine-stained tissues were acquired at multiple time points in the carcinogenesis process. Confocal fluorescence images of transverse fresh tissue slices from the same specimens were acquired to investigate how changes in tissue microarchitecture affect widefield fluorescence images of intact tissue. Widefield images were analyzed to develop and evaluate an algorithm to delineate areas of dysplasia and cancer. A classification algorithm for the presence of neoplasia based on the mean fluorescence intensity of 2-NBDG staining and the standard deviation of the fluorescence intensity of proflavine staining was found to separate moderate dysplasia, severe dysplasia, and cancer from non-neoplastic regions of interest with 91% sensitivity and specificity. Results suggest this combination of noninvasive optical imaging modalities can be used in vivo to discriminate non-neoplastic from neoplastic tissue in this model with the potential to translate this technology to the clinic.
Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues—Preliminary Results
NASA Astrophysics Data System (ADS)
Zhu, Ying; Bewer, Brian; Zhang, Honglin; Nichol, Helen; Thomlinson, Bill; Chapman, Dean
2010-06-01
Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson's disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X-ray Absorption Spectroscopy (XAS) and in particular X-ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra-dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X-ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.
X-ray fluorescence camera for imaging of iodine media in vivo.
Matsukiyo, Hiroshi; Watanabe, Manabu; Sato, Eiichi; Osawa, Akihiro; Enomoto, Toshiyuki; Nagao, Jiro; Abderyim, Purkhet; Aizawa, Katsuo; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Ehara, Shigeru; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2009-01-01
X-ray fluorescence (XRF) analysis is useful for measuring density distributions of contrast media in vivo. An XRF camera was developed for carrying out mapping for iodine-based contrast media used in medical angiography. Objects are exposed by an X-ray beam from a cerium target. Cerium K-series X-rays are absorbed effectively by iodine media in objects, and iodine fluorescence is produced from the objects. Next, iodine Kalpha fluorescence is selected out by use of a 58-microm-thick stannum filter and is detected by a cadmium telluride (CdTe) detector. The Kalpha rays are discriminated out by a multichannel analyzer, and the number of photons is counted by a counter card. The objects are moved and scanned by an x-y stage in conjunction with a two-stage controller, and X-ray images obtained by iodine mapping are shown on a personal computer monitor. The scan pitch of the x and y axes was 2.5 mm, and the photon counting time per mapping point was 2.0 s. We carried out iodine mapping of non-living animals (phantoms), and iodine Kalpha fluorescence was produced from weakly remaining iodine elements in a rabbit skin cancer.
Schwenck, Johannes; Maier, Florian C; Kneilling, Manfred; Wiehr, Stefan; Fuchs, Kerstin
2017-05-08
This paper describes a non-invasive method for imaging matrix metalloproteinases (MMP)-activity by an activatable fluorescent probe, via in vivo fluorescence optical imaging (OI), in two different mouse models of inflammation: a rheumatoid arthritis (RA) and a contact hypersensitivity reaction (CHR) model. Light with a wavelength in the near infrared (NIR) window (650 - 950 nm) allows a deeper tissue penetration and minimal signal absorption compared to wavelengths below 650 nm. The major advantages using fluorescence OI is that it is cheap, fast and easy to implement in different animal models. Activatable fluorescent probes are optically silent in their inactivated states, but become highly fluorescent when activated by a protease. Activated MMPs lead to tissue destruction and play an important role for disease progression in delayed-type hypersensitivity reactions (DTHRs) such as RA and CHR. Furthermore, MMPs are the key proteases for cartilage and bone degradation and are induced by macrophages, fibroblasts and chondrocytes in response to pro-inflammatory cytokines. Here we use a probe that is activated by the key MMPs like MMP-2, -3, -9 and -13 and describe an imaging protocol for near infrared fluorescence OI of MMP activity in RA and control mice 6 days after disease induction as well as in mice with acute (1x challenge) and chronic (5x challenge) CHR on the right ear compared to healthy ears.
Postscript: Distinguishing between Temporal Context and Short-Term Store
ERIC Educational Resources Information Center
Howard, Marc W.; Kahana, Michael J.; Sederberg, Per B.
2008-01-01
Space does not allow us to make detailed rebuttals to Davelaar, Usher, Haarmann, and Goshen-Gottstein's criticisms of the temporal context model's (TCM-A's) ability to account for dissociations between immediate and delayed recall nor to explain how TCM could account for list discrimination experiments. We agree that future work is needed to reach…
24 CFR 100.65 - Discrimination in terms, conditions and privileges and in services and facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... facilities. (a) It shall be unlawful, because of race, color, religion, sex, handicap, familial status, or..., religion, sex, handicap, familial status, or national origin. (2) Failing or delaying maintenance or repairs of sale or rental dwellings because of race, color, religion, sex, handicap, familial status, or...
Marijuana Effects on Human Forgetting Functions
ERIC Educational Resources Information Center
Lane, Scott D.; Cherek, Don R.; Lieving, Lori M.; Tcheremissine, Oleg V.
2005-01-01
It has long been known that acute marijuana administration impairs working memory (e.g., the discrimination of stimuli separated by a delay). The determination of which of the individual components of memory are altered by marijuana is an unresolved problem. Previous human studies did not use test protocols that allowed for the determination of…
Discriminated Timeout Avoidance in Pigeons: The Roles of Added Stimuli
ERIC Educational Resources Information Center
DeFulio, Anthony; Hackenberg, Timothy D.
2007-01-01
Two experiments examined pigeons' postponement of a signaled extinction period, or timeout (TO), from an ongoing schedule of response-dependent food delivery. A concurrent-operant procedure was used in which responses on one (food) key produced food according to a variable-interval schedule and responses on a second (postponement) key delayed the…
24 CFR 100.65 - Discrimination in terms, conditions and privileges and in services and facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... facilities. (a) It shall be unlawful, because of race, color, religion, sex, handicap, familial status, or..., religion, sex, handicap, familial status, or national origin. (2) Failing or delaying maintenance or repairs of sale or rental dwellings because of race, color, religion, sex, handicap, familial status, or...
24 CFR 100.65 - Discrimination in terms, conditions and privileges and in services and facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... facilities. (a) It shall be unlawful, because of race, color, religion, sex, handicap, familial status, or..., religion, sex, handicap, familial status, or national origin. (2) Failing or delaying maintenance or repairs of sale or rental dwellings because of race, color, religion, sex, handicap, familial status, or...
24 CFR 100.65 - Discrimination in terms, conditions and privileges and in services and facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... facilities. (a) It shall be unlawful, because of race, color, religion, sex, handicap, familial status, or..., religion, sex, handicap, familial status, or national origin. (2) Failing or delaying maintenance or repairs of sale or rental dwellings because of race, color, religion, sex, handicap, familial status, or...
24 CFR 100.65 - Discrimination in terms, conditions and privileges and in services and facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... facilities. (a) It shall be unlawful, because of race, color, religion, sex, handicap, familial status, or..., religion, sex, handicap, familial status, or national origin. (2) Failing or delaying maintenance or repairs of sale or rental dwellings because of race, color, religion, sex, handicap, familial status, or...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., storage and delay of assistive device, service animal problem, unsatisfactory information, and other. (d... carrier's or foreign carrier's services. (b) If you are a carrier covered by this part, conducting... disability. Data concerning the alleged discrimination or service problem related to the disability must be...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., storage and delay of assistive device, service animal problem, unsatisfactory information, and other. (d... carrier's or foreign carrier's services. (b) If you are a carrier covered by this part, conducting... disability. Data concerning the alleged discrimination or service problem related to the disability must be...
ERIC Educational Resources Information Center
Kisamore, April N.; Karsten, Amanda M.; Mann, Charlotte C.; Conde, Kerry Ann
2013-01-01
Axe (2008) speculated that some instances of intraverbal responding might be associated with limited or delayed acquisition because they require discrimination of multiple components of verbal stimuli. Past studies suggest that acquisition of responses under control of complex, multicomponent antecedent stimuli (e.g., conditional or compound…
Healthy Aging Delays Scalp EEG Sensitivity to Noise in a Face Discrimination Task
Rousselet, Guillaume A.; Gaspar, Carl M.; Pernet, Cyril R.; Husk, Jesse S.; Bennett, Patrick J.; Sekuler, Allison B.
2010-01-01
We used a single-trial ERP approach to quantify age-related changes in the time-course of noise sensitivity. A total of 62 healthy adults, aged between 19 and 98, performed a non-speeded discrimination task between two faces. Stimulus information was controlled by parametrically manipulating the phase spectrum of these faces. Behavioral 75% correct thresholds increased with age. This result may be explained by lower signal-to-noise ratios in older brains. ERP from each subject were entered into a single-trial general linear regression model to identify variations in neural activity statistically associated with changes in image structure. The fit of the model, indexed by R2, was computed at multiple post-stimulus time points. The time-course of the R2 function showed significantly delayed noise sensitivity in older observers. This age effect is reliable, as demonstrated by test–retest in 24 subjects, and started about 120 ms after stimulus onset. Our analyses suggest also a qualitative change from a young to an older pattern of brain activity at around 47 ± 4 years old. PMID:21833194
AIDS-related discrimination in Asia.
Paxton, S; Gonzales, G; Uppakaew, K; Abraham, K K; Okta, S; Green, C; Nair, K S; Merati, T Parwati; Thephthien, B; Marin, M; Quesada, A
2005-05-01
The Asia Pacific Network of People Living with HIV/AIDS (APN+) conducted the first regional documentation of AIDS-related discrimination in Asia. This project was an action-based, peer-implemented study that aimed to develop an understanding of the nature, pattern and extent of AIDS-related discrimination in several Asian countries. Trained HIV-positive people interviewed 764 positive people in four countries (India 302; Indonesia 42; Thailand 338; the Philippines 82) using a structured questionnaire. Findings indicate that the major area of discrimination in each country is within the health sector, where over half of those surveyed experienced some form of discrimination. In all countries, the majority of people did not receive pre-test counselling before being tested for HIV. People who reported coerced testing were significantly more likely than other respondents to face subsequent AIDS-related discrimination. A considerable number of respondents were refused treatment after being diagnosed with HIV and many experienced delayed provision of treatment or health services. Breaches of confidentiality by health workers were common. Within the family and the community, women were significantly more likely to experience discrimination than men, including ridicule and harassment, physical assault and being forced to change their place of residence because of their HIV status. These findings have serious implications, particularly in light of the increasing trend in many countries to test all pregnant women in order to prevent transmission of HIV to their unborn children.
Infants with Williams syndrome detect statistical regularities in continuous speech.
Cashon, Cara H; Ha, Oh-Ryeong; Graf Estes, Katharine; Saffran, Jenny R; Mervis, Carolyn B
2016-09-01
Williams syndrome (WS) is a rare genetic disorder associated with delays in language and cognitive development. The reasons for the language delay are unknown. Statistical learning is a domain-general mechanism recruited for early language acquisition. In the present study, we investigated whether infants with WS were able to detect the statistical structure in continuous speech. Eighteen 8- to 20-month-olds with WS were familiarized with 2min of a continuous stream of synthesized nonsense words; the statistical structure of the speech was the only cue to word boundaries. They were tested on their ability to discriminate statistically-defined "words" and "part-words" (which crossed word boundaries) in the artificial language. Despite significant cognitive and language delays, infants with WS were able to detect the statistical regularities in the speech stream. These findings suggest that an inability to track the statistical properties of speech is unlikely to be the primary basis for the delays in the onset of language observed in infants with WS. These results provide the first evidence of statistical learning by infants with developmental delays. Copyright © 2016 Elsevier B.V. All rights reserved.
Encoding of Spatio-Temporal Input Characteristics by a CA1 Pyramidal Neuron Model
Pissadaki, Eleftheria Kyriaki; Sidiropoulou, Kyriaki; Reczko, Martin; Poirazi, Panayiota
2010-01-01
The in vivo activity of CA1 pyramidal neurons alternates between regular spiking and bursting, but how these changes affect information processing remains unclear. Using a detailed CA1 pyramidal neuron model, we investigate how timing and spatial arrangement variations in synaptic inputs to the distal and proximal dendritic layers influence the information content of model responses. We find that the temporal delay between activation of the two layers acts as a switch between excitability modes: short delays induce bursting while long delays decrease firing. For long delays, the average firing frequency of the model response discriminates spatially clustered from diffused inputs to the distal dendritic tree. For short delays, the onset latency and inter-spike-interval succession of model responses can accurately classify input signals as temporally close or distant and spatially clustered or diffused across different stimulation protocols. These findings suggest that a CA1 pyramidal neuron may be capable of encoding and transmitting presynaptic spatiotemporal information about the activity of the entorhinal cortex-hippocampal network to higher brain regions via the selective use of either a temporal or a rate code. PMID:21187899
Mind the gap: temporal discrimination and dystonia.
Sadnicka, A; Daum, C; Cordivari, C; Bhatia, K P; Rothwell, J C; Manohar, S; Edwards, M J
2017-06-01
One of the most widely studied perceptual measures of sensory dysfunction in dystonia is the temporal discrimination threshold (TDT) (the shortest interval at which subjects can perceive that there are two stimuli rather than one). However the elevated thresholds described may be due to a number of potential mechanisms as current paradigms test not only temporal discrimination but also extraneous sensory and decision-making parameters. In this study two paradigms designed to better quantify temporal processing are presented and a decision-making model is used to assess the influence of decision strategy. 22 patients with cervical dystonia and 22 age-matched controls completed two tasks (i) temporal resolution (a randomized, automated version of existing TDT paradigms) and (ii) interval discrimination (rating the length of two consecutive intervals). In the temporal resolution task patients had delayed (P = 0.021) and more variable (P = 0.013) response times but equivalent discrimination thresholds. Modelling these effects suggested this was due to an increased perceptual decision boundary in dystonia with patients requiring greater evidence before committing to decisions (P = 0.020). Patient performance on the interval discrimination task was normal. Our work suggests that previously observed abnormalities in TDT may not be due to a selective sensory deficit of temporal processing as decision-making itself is abnormal in cervical dystonia. © 2017 EAN.
NASA Astrophysics Data System (ADS)
Chithra, K.; Vijayaraghavan, S.; Prakasarao, Aruna; Singaravelu, Ganesan
2017-02-01
The analysis of the variations in the spectroscopic patterns of the key bio molecules using Native fluorescence spectroscopy, without exogenous labels, has emerged as a new trend in the characterization of the Physiological State and the Discrimination of Pathological from normal conditions of cells and tissues as the relative concentration of these bio-molecules serve as markers in evaluating the presence of cancer in the body. The aim of this unique study is to use these features of Optical spectroscopy in monitoring the behavior of cells to treatment and thus to evaluate the response to Chemotherapeutic agents and Radiation in Breast Cancer Patients. The results of the study conducted using NFS of Human blood plasma of biopsy proved Breast Cancer patients undergoing treatment are promising, enhancing the scope of Native fluorescence Spectroscopy emerging as a promising technology in the evaluation of Therapeutic Response in Breast Cancer Patients.
Fluorescence correlation spectroscopy: the case of subdiffusion.
Lubelski, Ariel; Klafter, Joseph
2009-03-18
The theory of fluorescence correlation spectroscopy is revisited here for the case of subdiffusing molecules. Subdiffusion is assumed to stem from a continuous-time random walk process with a fat-tailed distribution of waiting times and can therefore be formulated in terms of a fractional diffusion equation (FDE). The FDE plays the central role in developing the fluorescence correlation spectroscopy expressions, analogous to the role played by the simple diffusion equation for regular systems. Due to the nonstationary nature of the continuous-time random walk/FDE, some interesting properties emerge that are amenable to experimental verification and may help in discriminating among subdiffusion mechanisms. In particular, the current approach predicts 1), a strong dependence of correlation functions on the initial time (aging); 2), sensitivity of correlation functions to the averaging procedure, ensemble versus time averaging (ergodicity breaking); and 3), that the basic mean-squared displacement observable depends on how the mean is taken.
Noise limitations of multiplier phototubes in the radiation environment of space
NASA Technical Reports Server (NTRS)
Viehmann, W.; Eubanks, A. G.
1976-01-01
The contributions of Cerenkov emission, luminescence, secondary electron emission, and bremsstrahlung to radiation-induced data current and noise of multiplier phototubes were analyzed quantitatively. Fluorescence and Cerenkov emission in the tube window are the major contributors and can quantitatively account for dark count levels observed in orbit. Radiation-induced noise can be minimized by shielding, tube selection, and mode of operation. Optical decoupling of windows and cathode (side-window tubes) leads to further reduction of radiation-induced dark counts, as does reducing the window thickness and effective cathode area, and selection of window/cathode combinations of low fluorescence efficiency. In trapped radiation-free regions of near-earth orbits and in free space, Cerenkov emission by relativistic particles contributes predominantly to the photoelectron yield per event. Operating multiplier phototubes in the photon (pulse) counting mode will discriminate against these large pulses and substantially reduce the dark count and noise to levels determined by fluorescence.
Song, Li; Hu, Yongsheng; Liu, Zheqin; Lv, Ying; Guo, Xiaoyang; Liu, Xingyuan
2017-01-25
The utilization of triplet excitons plays a key role in obtaining high emission efficiency for organic electroluminescent devices. However, to date, only phosphorescent materials have been implemented to harvest the triplet excitons in the organic light-emitting field effect transistors (OLEFETs). In this work, we report the first incorporation of exciplex thermally activated delayed fluorescence (TADF) emitters in heterostructured OLEFETs to harvest the triplet excitons. By developing a new kind of exciplex TADF emitter constituted by m-MTDATA (4,4',4″-tris(N-3-methylphenyl-N-phenylamino)triphenylamine) as the donor and OXD-7 (1,3-bis[2-(4-tert-butylphenyl)-1,3,4-oxadiazo-5-yl]benzene) as the acceptor, an exciton utilization efficiency of 74.3% for the devices was achieved. It is found that the injection barrier between hole transport layer and emission layer as well as the ratio between donor and acceptor would influence the external quantum efficiency (EQE) significantly. Devices with a maximum EQE of 3.76% which is far exceeding the reported results for devices with conventional fluorescent emitters were successfully demonstrated. Moreover, the EQE at high brightness even outperformed the result for organic light-emitting diode based on the same emitter. Our results demonstrate that the exciplex TADF emitters can be promising candidates to develop OLEFETs with high performance.
NASA Astrophysics Data System (ADS)
Zhang, Wenzhi; Jin, Jiangjiang; Huang, Zhi; Zhuang, Shaoqing; Wang, Lei
2016-07-01
Thermally activated delayed fluorescence (TADF) mechanism is a significant method that enables the harvesting of both triplet and singlet excitons for emission. However, up to now most efforts have been devoted to dealing with the relation between singlet-triplet splitting (ΔEST) and fluorescence efficiency, while the significance of spin-orbit coupling (SOC) is usually ignored. In this contribution, a new method is developed to realize high-efficiency TADF-based devices through simple device-structure optimizations. By inserting an ultrathin external heavy-atom (EHA) perturber layer in a desired manner, it provides useful means of accelerating the T1 → S1 reverse intersystem crossing (RISC) in TADF molecules without affecting the corresponding S1 → T1 process heavily. Furthermore, this strategy also promotes the utilization of host triplets through Förster mechanism during host → guest energy transfer (ET) processes, which helps to get rid of the solely dependence upon Dexter mechanism. Based on this strategy, we have successfully raised the external quantum efficiency (EQE) in 4CzPN-based devices by nearly 38% in comparison to control devices. These findings provide keen insights into the role of EHA played in TADF-based devices, offering valuable guidelines for utilizing certain TADF dyes which possess high radiative transition rate but relatively inefficient RISC.
Investigation of the influence of sampling schemes on quantitative dynamic fluorescence imaging
Dai, Yunpeng; Chen, Xueli; Yin, Jipeng; Wang, Guodong; Wang, Bo; Zhan, Yonghua; Nie, Yongzhan; Wu, Kaichun; Liang, Jimin
2018-01-01
Dynamic optical data from a series of sampling intervals can be used for quantitative analysis to obtain meaningful kinetic parameters of probe in vivo. The sampling schemes may affect the quantification results of dynamic fluorescence imaging. Here, we investigate the influence of different sampling schemes on the quantification of binding potential (BP) with theoretically simulated and experimentally measured data. Three groups of sampling schemes are investigated including the sampling starting point, sampling sparsity, and sampling uniformity. In the investigation of the influence of the sampling starting point, we further summarize two cases by considering the missing timing sequence between the probe injection and sampling starting time. Results show that the mean value of BP exhibits an obvious growth trend with an increase in the delay of the sampling starting point, and has a strong correlation with the sampling sparsity. The growth trend is much more obvious if throwing the missing timing sequence. The standard deviation of BP is inversely related to the sampling sparsity, and independent of the sampling uniformity and the delay of sampling starting time. Moreover, the mean value of BP obtained by uniform sampling is significantly higher than that by using the non-uniform sampling. Our results collectively suggest that a suitable sampling scheme can help compartmental modeling of dynamic fluorescence imaging provide more accurate results and simpler operations. PMID:29675325
NASA Astrophysics Data System (ADS)
Talite, M. J. A.; Lin, H. T.; Jiang, Z. C.; Lin, T. N.; Huang, H. Y.; Heredia, E.; Flores, A.; Chao, Y. C.; Shen, J. L.; Lin, C. A. J.; Yuan, C. T.
2016-08-01
Luminescent gold nanoclusters (AuNCs) with good biocompatibility have gained much attention in bio-photonics. In addition, they also exhibit a unique photo-physical property, namely thermally activated delayed fluorescence (TADF), by which both singlet and triplet excitons can be harvested. The combination of their non-toxic material property and unique TADF behavior makes AuNCs biocompatible nano-emitters for bio-related light-emitting devices. Unfortunately, the TADF emission is quenched when colloidal AuNCs are transferred to solid states under ambient environment. Here, a facile, low-cost and effective method was used to generate efficient and stable TADF emissions from solid AuNCs under ambient environment using polyvinyl alcohol as a solid matrix. To unravel the underlying mechanism, temperature-dependent static and transient photoluminescence measurements were performed and we found that two factors are crucial for solid TADF emission: small energy splitting between singlet and triplet states and the stabilization of the triplet states. Solid TADF films were also deposited on the flexible plastic substrate with patterned structures, thus mitigating the waveguide-mode losses. In addition, we also demonstrated that warm white light can be generated based on a co-doped single emissive layer, consisting of non-toxic, solution-processed TADF AuNCs and fluorescent carbon dots under UV excitation.
Deng, Fan; Blumhoff, Jörg; Castellano, Felix N
2013-05-30
Noncoherent sensitized green-to-near-visible upconversion has been achieved utilizing palladium(II) octaethylporphyrin (PdOEP) as the triplet sensitizer and anthracene as the energy acceptor/annihilator in vacuum degassed toluene. Selective 547 nm excitation of PdOEP with incident irradiance as low as 600 μW/cm(2) results in the observation of anthryl fluorescence at higher energy. Stern-Volmer analysis of the dynamic phosphorescence quenching of PdOEP by anthracene possesses an extremely large K(SV) of 810,000 M(-1), yielding a triplet-triplet energy transfer quenching constant of 3.3 × 10(9) M(-1) s(-1). Clear evidence for the subsequent triplet-triplet annihilation (TTA) of anthracene was afforded by numerous experiments, one of the most compelling was an excitation scan illustrating that the Q-band absorption features of PdOEP are solely responsible for sensitizing the anti-Stokes fluorescence. The upconverted emission intensity with respect to the excitation power was shown to vary between quadratic and linear using either coherent or noncoherent light sources, illustrating the expected kinetic limits for the light producing photochemistry under continuous wave illumination. Time-resolved experiments directly comparing the total integrated anthracene intensity/time fluorescence data produced through upconversion (λ(ex) = 547 nm, delayed signal) and with direct excitation (λ(ex) = 355 nm, prompt signal) under conditions where the laser pulse is completely absorbed by the sample reveal annihilation efficiencies of approximately 40%. Similarly, the delayed fluorescence kinetic analysis reported by Schmidt and co-workers (J. Phys. Chem. Lett. 2010, 1, 1795-1799) was used to reveal the maximum possible efficiency from a model red-to-yellow upconverting composition and this treatment was applied to the anthryl triplet absorption decay transients of anthracene measured for the PdOEP/anthracene composition at 430 nm. From this analysis approximately 50% of the anthryl triplets that decay by TTA produce singlet fluorescence, consistent with the notion that annihilation spin statistics does not impose efficiency limits on upconversion photochemistry.
NASA Astrophysics Data System (ADS)
Díaz-Ayil, Gilberto; Amouroux, Marine; Clanché, Fabien; Granjon, Yves; Blondel, Walter C. P. M.
2009-07-01
Spatially-resolved bimodal spectroscopy (multiple AutoFluorescence AF excitation and Diffuse Reflectance DR), was used in vivo to discriminate various healthy and precancerous skin stages in a pre-clinical model (UV-irradiated mouse): Compensatory Hyperplasia CH, Atypical Hyperplasia AH and Dysplasia D. A specific data preprocessing scheme was applied to intensity spectra (filtering, spectral correction and intensity normalization), and several sets of spectral characteristics were automatically extracted and selected based on their discrimination power, statistically tested for every pair-wise comparison of histological classes. Data reduction with Principal Components Analysis (PCA) was performed and 3 classification methods were implemented (k-NN, LDA and SVM), in order to compare diagnostic performance of each method. Diagnostic performance was studied and assessed in terms of Sensibility (Se) and Specificity (Sp) as a function of the selected features, of the combinations of 3 different inter-fibres distances and of the numbers of principal components, such that: Se and Sp ~ 100% when discriminating CH vs. others; Sp ~ 100% and Se > 95% when discriminating Healthy vs. AH or D; Sp ~ 74% and Se ~ 63% for AH vs. D.
Kondakov, Denis Y
2015-06-28
Studies of delayed electroluminescence in highly efficient fluorescent organic light-emitting diodes (OLEDs) of many dissimilar architectures indicate that the triplet-triplet annihilation (TTA) significantly increases yield of excited singlet states-emitting molecules in this type of device thereby contributes substantially to their efficiency. Towards the end of the 2000s, the essential role of TTA in realizing highly efficient fluorescent devices was widely recognized. Analysis of a diverse set of fluorescent OLEDs shows that high efficiencies are often cor-related to TTA extents. It is therefore likely that it is the long-term empirical optimization of OLED efficiencies that has resulted in fortuitous emergence of TTA as a large and ubiquitous contributor to efficiency. TTA contributions as high as 20-30% are common in the state-of-the-art OLEDs, and even become dominant in special cases, where TTA is shown to substantially exceed the spin-statistical limit. The fundamental features of OLED efficiency enhancement via TTA-molecular structure-dependent contributions, current density-dependent intensities in practical devices and frequently observed antagonistic relationships between TTA extent and OLED lifetime-came to be understood over the course of the next few years. More recently, however, there was much less reported progress with respect to all-important quantitative details of the TTA mechanism. It should be emphasized that, to this day and despite the decades of work on improving blue phosphorescent OLEDs as well as the recent advent of thermally activated delayed fluorescence OLEDs, the majority of practical blue OLEDs still rely on TTA. Considering such practical importance of fluorescent blue OLEDs, the design of blue OLED-compatible materials capable of substantially exceeding the spin-statistical limit in TTA, elimination of the antagonistic relationship between TTA-related efficiency gains and lifetime losses, and designing devices with an extended range of current densities producing near-maximum TTA electroluminescence are the areas where future improvements would be most beneficial. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
Turchi, Janita; Buffalari, Deanne; Mishkin, Mortimer
2008-01-01
Monkeys trained in either one-trial recognition at 8- to 10-min delays or multi-trial discrimination habits with 24-h intertrial intervals received systemic cholinergic and dopaminergic antagonists, scopolamine and haloperidol, respectively, in separate sessions. Recognition memory was impaired markedly by scopolamine but not at all by haloperidol, whereas habit formation was impaired markedly by haloperidol but only minimally by scopolamine. These differential drug effects point to differences in synaptic modification induced by the two neuromodulators that parallel the contrasting properties of the two types of learning, namely, fast acquisition but weak retention of memories versus slow acquisition but durable retention of habits. PMID:18685146
Turchi, Janita; Buffalari, Deanne; Mishkin, Mortimer
2008-08-01
Monkeys trained in either one-trial recognition at 8- to 10-min delays or multi-trial discrimination habits with 24-h intertrial intervals received systemic cholinergic and dopaminergic antagonists, scopolamine and haloperidol, respectively, in separate sessions. Recognition memory was impaired markedly by scopolamine but not at all by haloperidol, whereas habit formation was impaired markedly by haloperidol but only minimally by scopolamine. These differential drug effects point to differences in synaptic modification induced by the two neuromodulators that parallel the contrasting properties of the two types of learning, namely, fast acquisition but weak retention of memories versus slow acquisition but durable retention of habits.
Study of improving signal-noise ratio for fluorescence channel
NASA Astrophysics Data System (ADS)
Wang, Guoqing; Li, Xin; Lou, Yue; Chen, Dong; Zhao, Xin; Wang, Ran; Yan, Debao; Zhao, Qi
2017-10-01
Laser-induced fluorescence(LIFS), which is one of most effective discrimination methods to identify the material at the molecular level by inducing fluorescence spectrum, has been popularized for its fast and accurate probe's results. According to the research, violet laser or ultraviolet laser is always used as excitation light source. While, There is no atmospheric window for violet laser and ultraviolet laser, causing laser attenuation along its propagation path. What's worse, as the laser reaching sample, part of the light is reflected. That is, excitation laser really react on sample to produce fluorescence is very poor, leading to weak fluorescence mingled with the background light collected by LIFS' processing unit, when it used outdoor. In order to spread LIFS to remote probing under the complex background, study of improving signal-noise ratio for fluorescence channel is a meaningful work. Enhancing the fluorescence intensity and inhibiting background light both can improve fluorescence' signal-noise ratio. In this article, three different approaches of inhibiting background light are discussed to improve the signal-noise ratio of LIFS. The first method is increasing fluorescence excitation area in the proportion of LIFS' collecting field by expanding laser beam, if the collecting filed is fixed. The second one is changing field angle base to accommodate laser divergence angle. The third one is setting a very narrow gating circuit to control acquisition circuit, which is shortly open only when fluorescence arriving. At some level, these methods all can reduce the background light. But after discussion, the third one is best with adding gating acquisition circuit to acquisition circuit instead of changing light path, which is effective and economic.
Nokia, Miriam S; Wikgren, Jan
2010-04-01
The relative power of the hippocampal theta-band ( approximately 6 Hz) activity (theta ratio) is thought to reflect a distinct neural state and has been shown to affect learning rate in classical eyeblink conditioning in rabbits. We sought to determine if the theta ratio is mostly related to the detection of the contingency between the stimuli used in conditioning or also to the learning of more complex inhibitory associations when a highly demanding delay discrimination-reversal eyeblink conditioning paradigm is used. A high hippocampal theta ratio was not only associated with a fast increase in conditioned responding in general but also correlated with slow emergence of discriminative responding due to sustained responding to the conditioned stimulus not paired with an unconditioned stimulus. The results indicate that the neural state reflected by the hippocampal theta ratio is specifically linked to forming associations between stimuli rather than to the learning of inhibitory associations needed for successful discrimination. This is in line with the view that the hippocampus is responsible for contingency detection in the early phase of learning in eyeblink conditioning. (c) 2009 Wiley-Liss, Inc.
Adams, Michelle M; Anslyn, Eric V
2009-12-02
There has been a growing interest in the use of differential sensing for analyte classification. In an effort to mimic the mammalian senses of taste and smell, which utilize protein-based receptors, we have introduced serum albumins as nonselective receptors for recognition of small hydrophobic molecules. Herein, we employ a sensing ensemble consisting of serum albumins, a hydrophobic fluorescent indicator (PRODAN), and a hydrophobic additive (deoxycholate) to detect terpenes. With the aid of linear discriminant analysis, we successfully applied our system to differentiate five terpenes. We then extended our terpene analysis and utilized our sensing ensemble for terpene discrimination within the complex mixtures found in perfume.
Digitally synthesized beat frequency-multiplexed fluorescence lifetime spectroscopy
Chan, Jacky C. K.; Diebold, Eric D.; Buckley, Brandon W.; Mao, Sien; Akbari, Najva; Jalali, Bahram
2014-01-01
Frequency domain fluorescence lifetime imaging is a powerful technique that enables the observation of subtle changes in the molecular environment of a fluorescent probe. This technique works by measuring the phase delay between the optical emission and excitation of fluorophores as a function of modulation frequency. However, high-resolution measurements are time consuming, as the excitation modulation frequency must be swept, and faster low-resolution measurements at a single frequency are prone to large errors. Here, we present a low cost optical system for applications in real-time confocal lifetime imaging, which measures the phase vs. frequency spectrum without sweeping. Deemed Lifetime Imaging using Frequency-multiplexed Excitation (LIFE), this technique uses a digitally-synthesized radio frequency comb to drive an acousto-optic deflector, operated in a cat’s-eye configuration, to produce a single laser excitation beam modulated at multiple beat frequencies. We demonstrate simultaneous fluorescence lifetime measurements at 10 frequencies over a bandwidth of 48 MHz, enabling high speed frequency domain lifetime analysis of single- and multi-component sample mixtures. PMID:25574449