Sample records for demonstrate good reliability

  1. Development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS)

    PubMed Central

    2013-01-01

    Background Streetscape (microscale) features of the built environment can influence people’s perceptions of their neighborhoods’ suitability for physical activity. Many microscale audit tools have been developed, but few have published systematic scoring methods. We present the development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS) tool and its theoretically-based subscales. Methods MAPS was based on prior instruments and was developed to assess details of streetscapes considered relevant for physical activity. MAPS sections (route, segments, crossings, and cul-de-sacs) were scored by two independent raters for reliability analyses. There were 290 route pairs, 516 segment pairs, 319 crossing pairs, and 53 cul-de-sac pairs in the reliability sample. Individual inter-rater item reliability analyses were computed using Kappa, intra-class correlation coefficient (ICC), and percent agreement. A conceptual framework for subscale creation was developed using theory, expert consensus, and policy relevance. Items were grouped into subscales, and subscales were analyzed for inter-rater reliability at tiered levels of aggregation. Results There were 160 items included in the subscales (out of 201 items total). Of those included in the subscales, 80 items (50.0%) had good/excellent reliability, 41 items (25.6%) had moderate reliability, and 18 items (11.3%) had low reliability, with limited variability in the remaining 21 items (13.1%). Seventeen of the 20 route section subscales, valence (positive/negative) scores, and overall scores (85.0%) demonstrated good/excellent reliability and 3 demonstrated moderate reliability. Of the 16 segment subscales, valence scores, and overall scores, 12 (75.0%) demonstrated good/excellent reliability, three demonstrated moderate reliability, and one demonstrated poor reliability. Of the 8 crossing subscales, valence scores, and overall scores, 6 (75.0%) demonstrated good/excellent reliability, and 2 demonstrated moderate reliability. The cul-de-sac subscale demonstrated good/excellent reliability. Conclusions MAPS items and subscales predominantly demonstrated moderate to excellent reliability. The subscales and scoring system represent a theoretically based framework for using these complex microscale data and may be applicable to other similar instruments. PMID:23621947

  2. Reliability analysis for digital adolescent idiopathic scoliosis measurements.

    PubMed

    Kuklo, Timothy R; Potter, Benjamin K; O'Brien, Michael F; Schroeder, Teresa M; Lenke, Lawrence G; Polly, David W

    2005-04-01

    Analysis of adolescent idiopathic scoliosis (AIS) requires a thorough clinical and radiographic evaluation to completely assess the three-dimensional deformity. Recently, these radiographic parameters have been analyzed for reliability and reproducibility following manual measurements; however, most of these parameters have not been analyzed with regard to digital measurements. The purpose of this study is to determine the intra- and interobserver reliability of common scoliosis radiographic parameters using a digital software measurement program. Thirty sets of preoperative (posteroanterior [PA], lateral, and side-bending [SB]) and postoperative (PA and lateral) radiographs were analyzed by three independent observers on two separate occasions using a software measurement program (PhDx, Albuquerque, NM). Coronal measures included main thoracic (MT) and thoracolumbar-lumbar (TL/L) Cobb, SB MT Cobb, MT and TL/L apical vertical translation (AVT), C7 to center sacral vertical line (CSVL), T1 tilt, LIV tilt, disk below lowest instrumented vertebra (LIV), coronal balance, and Risser, whereas sagittal measures included T2-T5, T5-T12, T2-T12, T10-L2, T12-S1, and sagittal balance. Analysis of variance for repeated measures or Cohen three-way kappa correlation coefficient analysis was performed as appropriate to calculate the intra- and interobserver reliability for each parameter. The majority of the radiographic parameters assessed demonstrated good or excellent intra- and interobserver reliability. The relationship of the LIV to the CSVL (intraobserver kappaa = 0.48-0.78, fair to excellent; interobserver kappaa = 0.34-0.41, fair to poor), interobserver measurement of AVT (rho = 0.49-0.73, low to good), Risser grade (intraobserver rho = 0.41-0.97, low to excellent; interobserver rho = 0.60-0.70, fair to good), intraobserver measurement of the angulation of the disk inferior to the LIV (rho = 0.53-0.88, fair to good), apical Nash-Moe vertebral rotation (intraobserver rho = 0.50-0.85, fair to good; interobserver rho = 0.53-0.59, fair), and especially regional thoracic kyphosis from T2 to T5 (intraobserver rho = 0.22-0.65, poor to fair; interobserver rho = 0.33-0.47, low) demonstrated lesser reliability. In general, preoperative measures demonstrated greater reliability than postoperative measures, and coronal angular measures were more reliable than sagittal measures. Most common radiographic parameters for AIS assessment demonstrated good or excellent reliability for digital measurement and can be recommended for routine clinical and academic use. Preoperative assessments and coronal measures may be more reliable than postoperative and sagittal measurements. The reliability of digital measurements will be increasingly important as digital radiographic viewing becomes commonplace.

  3. Development and psychometric evaluation of an information literacy self-efficacy survey and an information literacy knowledge test.

    PubMed

    Tepe, Rodger; Tepe, Chabha

    2015-03-01

    To develop and psychometrically evaluate an information literacy (IL) self-efficacy survey and an IL knowledge test. In this test-retest reliability study, a 25-item IL self-efficacy survey and a 50-item IL knowledge test were developed and administered to a convenience sample of 53 chiropractic students. Item analyses were performed on all questions. The IL self-efficacy survey demonstrated good reliability (test-retest correlation = 0.81) and good/very good internal consistency (mean κ = .56 and Cronbach's α = .92). A total of 25 questions with the best item analysis characteristics were chosen from the 50-item IL knowledge test, resulting in a 25-item IL knowledge test that demonstrated good reliability (test-retest correlation = 0.87), very good internal consistency (mean κ = .69, KR20 = 0.85), and good item discrimination (mean point-biserial = 0.48). This study resulted in the development of three instruments: a 25-item IL self-efficacy survey, a 50-item IL knowledge test, and a 25-item IL knowledge test. The information literacy self-efficacy survey and the 25-item version of the information literacy knowledge test have shown preliminary evidence of adequate reliability and validity to justify continuing study with these instruments.

  4. Development and psychometric evaluation of an information literacy self-efficacy survey and an information literacy knowledge test*

    PubMed Central

    Tepe, Rodger; Tepe, Chabha

    2015-01-01

    Objective To develop and psychometrically evaluate an information literacy (IL) self-efficacy survey and an IL knowledge test. Methods In this test–retest reliability study, a 25-item IL self-efficacy survey and a 50-item IL knowledge test were developed and administered to a convenience sample of 53 chiropractic students. Item analyses were performed on all questions. Results The IL self-efficacy survey demonstrated good reliability (test–retest correlation = 0.81) and good/very good internal consistency (mean κ = .56 and Cronbach's α = .92). A total of 25 questions with the best item analysis characteristics were chosen from the 50-item IL knowledge test, resulting in a 25-item IL knowledge test that demonstrated good reliability (test–retest correlation = 0.87), very good internal consistency (mean κ = .69, KR20 = 0.85), and good item discrimination (mean point-biserial = 0.48). Conclusions This study resulted in the development of three instruments: a 25-item IL self-efficacy survey, a 50-item IL knowledge test, and a 25-item IL knowledge test. The information literacy self-efficacy survey and the 25-item version of the information literacy knowledge test have shown preliminary evidence of adequate reliability and validity to justify continuing study with these instruments. PMID:25517736

  5. Reliability and diagnostic characteristics of the JFK coma recovery scale-revised: exploring the influence of rater's level of experience.

    PubMed

    Løvstad, Marianne; Frøslie, Kathrine F; Giacino, Joseph T; Skandsen, Toril; Anke, Audny; Schanke, Anne-Kristine

    2010-01-01

    To confirm the reliability and diagnostic validity of the JFK Coma Recovery Scale-Revised (CRS-R) across raters with varying levels of experience. Thirty-one patients with disorders of consciousness were recruited from 6 Norwegian hospitals. CRS-R and the Disability Rating Scale. Reliability measures were good for the CRS-R total scores and moderate to good for its subscales. Diagnostic agreement among examiners was good. Raters' experience with the CRS-R favorably influenced reliability. Sensitivity and specificity analyses demonstrated better detection of patients in minimally conscious state on the CRS-R relative to the Disability Rating Scale. The CRS-R is a reliable tool for diagnosing vegetative state and minimally conscious state. Raters' level of experience influences the reliability of the CRS-R scores.

  6. Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion.

    PubMed

    Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A

    2015-05-01

    Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Quantifying frontal plane knee motion during single limb squats: reliability and validity of 2-dimensional measures.

    PubMed

    Gwynne, Craig R; Curran, Sarah A

    2014-12-01

    Clinical assessment of lower limb kinematics during dynamic tasks may identify individuals who demonstrate abnormal movement patterns that may lead to etiology of exacerbation of knee conditions such as patellofemoral joint (PFJt) pain. The purpose of this study was to determine the reliability, validity and associated measurement error of a clinically appropriate two-dimensional (2-D) procedure of quantifying frontal plane knee alignment during single limb squats. Nine female and nine male recreationally active subjects with no history of PFJt pain had frontal plane limb alignment assessed using three-dimensional (3-D) motion analysis and digital video cameras (2-D analysis) while performing single limb squats. The association between 2-D and 3-D measures was quantified using Pearson's product correlation coefficients. Intraclass correlation coefficients (ICCs) were determined for within- and between-session reliability of 2-D data and standard error of measurement (SEM) was used to establish measurement error. Frontal plane limb alignment assessed with 2-D analysis demonstrated good correlation compared with 3-D methods (r = 0.64 to 0.78, p < 0.001). Within-session (0.86) and between-session ICCs (0.74) demonstrated good reliability for 2-D measures and SEM scores ranged from 2° to 4°. 2-D measures have good consistency and may provide a valid measure of lower limb alignment when compared to existing 3-D methods. Assessment of lower limb kinematics using 2-D methods may be an accurate and clinically useful alternative to 3-D motion analysis when identifying individuals who demonstrate abnormal movement patterns associated with PFJt pain. 2b.

  8. Psychometrics of the MHSIP Adult Consumer Survey.

    PubMed

    Jerrell, Jeanette M

    2006-10-01

    The reliability and validity of the Mental Health Statistics Improvement Program (MHSIP) Adult Consumer Survey were assessed in a statewide convenience sample of 459 persons with severe mental illness served through a public mental health system. Consistent with previous findings and the intent of its developers, three factors were identified that demonstrate good internal consistency, moderate test-retest reliability, and good convergent validity with consumer perceptions of other aspects of their care. The reliability and validity of the MHSIP Adult Consumer Survey documented in this study underscore its scientific and practical utility as an abbreviated tool for assessing access, quality and appropriateness, and outcome in mental health service systems.

  9. Development, reliability, and validity of the My Child's Play (MCP) questionnaire.

    PubMed

    Schneider, Eleanor; Rosenblum, Sara

    2014-01-01

    This article describes the development, reliability, and validity of My Child's Play (MCP), a parent questionnaire designed to evaluate the play of children ages 3-9 yr. The first phase of the study determined the questionnaire's content and face validity. Subsequently, the internal reliability consistency and construct and concurrent validity were demonstrated using 334 completed questionnaires. The MCP showed good internal consistency (α = .86). The factor analysis revealed four distinct factors with acceptable levels of internal reliability (Cronbach's αs = .63-.81) and gender- and age-related differences in play characteristics; both findings attest to the tool's construct validity. Significant correlations (r = .33, p < .0001) with the Parent as a Teacher Inventory demonstrate the MCP's concurrent validity. The MCP demonstrated acceptable reliability and validity. It appears to be a promising standardized assessment tool for use in research and practice to promote understanding of a child's play. Copyright © 2014 by the American Occupational Therapy Association, Inc.

  10. Scoring ultrasound synovitis in rheumatoid arthritis: a EULAR-OMERACT ultrasound taskforce-Part 2: reliability and application to multiple joints of a standardised consensus-based scoring system

    PubMed Central

    Terslev, Lene; Naredo, Esperanza; Aegerter, Philippe; Wakefield, Richard J; Backhaus, Marina; Balint, Peter; Bruyn, George A W; Iagnocco, Annamaria; Jousse-Joulin, Sandrine; Schmidt, Wolfgang A; Szkudlarek, Marcin; Conaghan, Philip G; Filippucci, Emilio

    2017-01-01

    Objectives To test the reliability of new ultrasound (US) definitions and quantification of synovial hypertrophy (SH) and power Doppler (PD) signal, separately and in combination, in a range of joints in patients with rheumatoid arthritis (RA) using the European League Against Rheumatisms–Outcomes Measures in Rheumatology (EULAR-OMERACT) combined score for PD and SH. Methods A stepwise approach was used: (1) scoring static images of metacarpophalangeal (MCP) joints in a web-based exercise and subsequently when scanning patients; (2) scoring static images of wrist, proximal interphalangeal joints, knee and metatarsophalangeal joints in a web-based exercise and subsequently when scanning patients using different acquisitions (standardised vs usual practice). For reliability, kappa coefficients (κ) were used. Results Scoring MCP joints in static images showed substantial intraobserver variability but good to excellent interobserver reliability. In patients, intraobserver reliability was the same for the two acquisition methods. Interobserver reliability for SH (κ=0.87) and PD (κ=0.79) and the EULAR-OMERACT combined score (κ=0.86) were better when using a ‘standardised’ scan. For the other joints, the intraobserver reliability was excellent in static images for all scores (κ=0.8–0.97) and the interobserver reliability marginally lower. When using standardised scanning in patients, the intraobserver was good (κ=0.64 for SH and the EULAR-OMERACT combined score, 0.66 for PD) and the interobserver reliability was also good especially for PD (κ range=0.41–0.92). Conclusion The EULAR-OMERACT score demonstrated moderate-good reliability in MCP joints using a standardised scan and is equally applicable in non-MCP joints. This scoring system should underpin improved reliability and consequently the responsiveness of US in RA clinical trials. PMID:28948984

  11. Development and validation of the sociocultural attitudes towards appearance questionnaire-4-revised (SATAQ-4R).

    PubMed

    Schaefer, Lauren M; Harriger, Jennifer A; Heinberg, Leslie J; Soderberg, Taylor; Kevin Thompson, J

    2017-02-01

    The Sociocultural Attitudes Toward Appearance Questionnaire-4 (SATAQ-4) is a measure of internalization of appearance ideals (i.e., personal acceptance of societal ideals) and appearance pressures (i.e., pressures to achieve the societal ideal). The current study sought to address limitations of the scale in order to increase precision in the measurement of muscular ideal internalization, include an assessment of one's desire for attractiveness, and broaden the measurement of appearance-related pressures. The factor structure, reliability and construct validity of the SATAQ-4-Revised were examined among college women (N = 1,114) in Study 1, adolescent girls (N = 275) in Study 2, and college men (N = 290) in Study 3. Factor analysis among college women indicated a 7-factor 31-item scale, labeled the SATAQ-4R-Female: (1) Internalization: Thin/Low Body Fat, (2) Internalization: Muscular, (3) Internalization: General Attractiveness, (4) Pressures: Family, (5) Pressures: Media, (6) Pressures: Peers, and (7) Pressures: Significant Others. SATAQ-4R-Female subscales demonstrated good reliability and construct validity among college women. Examination of the SATAQ-4R-Female among adolescent girls suggested a six-factor scale in which peer and significant others items comprised a single subscale. The scale demonstrated good reliability and construct validity in adolescent girls. Examination of the SATAQ-4R among men produced a 28-item scale with seven factors paralleling the factors identified among college women. This scale, labeled the SATAQ-4R-Male, demonstrated good reliability and construct validity. Results support the reliability and validity of SATAQ-4R-Female in college women and adolescent girls, and the SATAQ-4R-Male in college men. © 2016 Wiley Periodicals, Inc.(Int J Eat Disord 2017; 50:104-117). © 2016 Wiley Periodicals, Inc.

  12. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    PubMed

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; p<0.05). The questionnaire had also been demonstrated to have a good validity with a proven high correlation to each question of SF-36 (p<0.05). the Indonesian version of GERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  13. Identifying and classifying hyperostosis frontalis interna via computerized tomography.

    PubMed

    May, Hila; Peled, Nathan; Dar, Gali; Hay, Ori; Abbas, Janan; Masharawi, Youssef; Hershkovitz, Israel

    2010-12-01

    The aim of this study was to recognize the radiological characteristics of hyperostosis frontalis interna (HFI) and to establish a valid and reliable method for its identification and classification. A reliability test was carried out on 27 individuals who had undergone a head computerized tomography (CT) scan. Intra-observer reliability was obtained by examining the images three times, by the same researcher, with a 2-week interval between each sample ranking. The inter-observer test was performed by three independent researchers. A validity test was carried out using two methods for identifying and classifying HFI: 46 cadaver skullcaps were ranked twice via computerized tomography scans and then by direct observation. Reliability and validity were calculated using Kappa test (SPSS 15.0). Reliability tests of ranking HFI via CT scans demonstrated good results (K > 0.7). As for validity, a very good consensus was obtained between the CT and direct observation, when moderate and advanced types of HFI were present (K = 0.82). The suggested classification method for HFI, using CT, demonstrated a sensitivity of 84%, specificity of 90.5%, and positive predictive value of 91.3%. In conclusion, volume rendering is a reliable and valid tool for identifying HFI. The suggested three-scale classification is most suitable for radiological diagnosis of the phenomena. Considering the increasing awareness of HFI as an early indicator of a developing malady, this study may assist radiologists in identifying and classifying the phenomena.

  14. Reliability and validity of the German version of the Utrecht Questionnaire for Outcome Assessment in Aesthetic Rhinoplasty (D-OAR).

    PubMed

    Spiekermann, Christoph; Rudack, Claudia; Stenner, Markus

    2017-11-01

    The outcome of aesthetic rhinoplasty is determined by the patient's subjective satisfaction with the nasal appearance which is difficult to assess. The Utrecht Questionnaire for Outcome Assessment in Aesthetic Rhinoplasty (OAR) is a brief and reliable instrument to assess the influence of the subjective nasal appearance on quality of life in patients undergoing aesthetic rhinoplasty. Preoperative application of this questionnaire reveals important aspects and possible disturbances of the body image which could be negative predictors concerning the result. On the other hand, it represents an appropriate tool to assess the postoperative outcome. The aim of this study was to determine the validity, reliability and responsiveness of the adapted German version of the OAR (D-OAR). The adaption of the OAR to German language was performed by a forward and backward translation process. Patients undergoing rhinoplasty were asked to complete the D-OAR preoperatively, 1, 3 and 12 months after procedure and healthy volunteers without any nasal complaints served as controls to test validity, reliability and responsiveness. An excellent internal consistency, a good test-retest reliability and good inter-item and item-total correlations demonstrated a good reliability of the D-OAR. The convincing validity of the adapted version was proven by an excellent discriminant and a sufficient content validity. Significant differences between pre- and postoperative D-OAR scores revealed a good responsiveness of the instrument. Hence, with a sufficient validity, reliability and sensitivity to changes, the D-OAR is a short and helpful instrument to assess the subjective perception of the nasal appearance in German patients.

  15. Validation of the Short Form of the Academic Procrastination Scale.

    PubMed

    Yockey, Ronald D

    2016-02-01

    The factor structure, internal consistency reliability, and convergent validity of the five-item Academic Procrastination Scale-Short Form was investigated on an ethnically diverse sample of college students. The results provided support for the Academic Procrastination Scale-Short Form as a unidimensional measure of academic procrastination, which possessed good internal consistency reliability in this sample of 282 students. The scale also demonstrated good convergent validity, with moderate to large correlations with both the Procrastination Assessment Scale-Students and the Tuckman Procrastination Scale. Implications of the results are discussed and recommendations for future work provided.

  16. Post-operative rotator cuff integrity, based on Sugaya's classification, can reflect abduction muscle strength of the shoulder.

    PubMed

    Yoshida, Masahito; Collin, Phillipe; Josseaume, Thierry; Lädermann, Alexandre; Goto, Hideyuki; Sugimoto, Katumasa; Otsuka, Takanobu

    2018-01-01

    Magnetic resonance (MR) imaging is common in structural and qualitative assessment of the rotator cuff post-operatively. Rotator cuff integrity has been thought to be associated with clinical outcome. The purpose of this study was to evaluate the inter-observer reliability of cuff integrity (Sugaya's classification) and assess the correlation between Sugaya's classification and the clinical outcome. It was hypothesized that Sugaya's classification would show good reliability and good correlation with the clinical outcome. Post-operative MR images were taken two years post-operatively, following arthroscopic rotator cuff repair. For assessment of inter-rater reliability, all radiographic evaluations for the supraspinatus muscle were done by two orthopaedic surgeons and one radiologist. Rotator cuff integrity was classified into five categories, according to Sugaya's classification. Fatty infiltration was graded into four categories, based on the Fuchs' classification grading system. Muscle hypotrophy was graded as four grades, according to the scale proposed by Warner. The clinical outcome was assessed according to the constant scoring system pre-operatively and 2 years post-operatively. Of the sixty-two consecutive patients with full-thickness rotator cuff tears, fifty-two patients were reviewed in this study. These subjects included twenty-three men and twenty-nine women, with an average age of fifty-seven years. In terms of the inter-rater reliability between orthopaedic surgeons, Sugaya's classification showed the highest agreement [ICC (2.1) = 0.82] for rotator cuff integrity. The grade of fatty infiltration and muscle atrophy demonstrated good agreement, respectively (0.722 and 0.758). With regard to the inter-rater reliability between orthopaedic surgeon and radiologist, Sugaya's classification showed good reliability [ICC (2.1) = 0.70]. On the other hand, fatty infiltration and muscle hypotrophy classifications demonstrated fair and moderate agreement [ICC (2.1) = 0.39 and 0.49]. Although no significant correlation was found between overall post-operative constant score and Sugaya's classification, Sugaya's classification indicated significant correlation with the muscle strength score. Sugaya's classification showed repeatability and good agreement between the orthopaedist and radiologist, who are involved in the patient care for the rotator cuff tear. Common classification of rotator cuff integrity with good reliability will give appropriate information for clinicians to improve the patient care of the rotator cuff tear. This classification also would be helpful to predict the strength of arm abduction in the scapular plane. IV.

  17. Test-retest reliability and construct validity of the ENERGY-child questionnaire on energy balance-related behaviours and their potential determinants: the ENERGY-project.

    PubMed

    Singh, Amika S; Vik, Froydis N; Chinapaw, Mai J M; Uijtdewilligen, Léonie; Verloigne, Maïté; Fernández-Alvira, Juan M; Stomfai, Sarolta; Manios, Yannis; Martens, Marloes; Brug, Johannes

    2011-12-09

    Insight in children's energy balance-related behaviours (EBRBs) and their determinants is important to inform obesity prevention research. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. To examine the test-retest reliability and construct validity of the child questionnaire used in the ENERGY-project, measuring EBRBs and their potential determinants among 10-12 year old children. We collected data among 10-12 year old children (n = 730 in the test-retest reliability study; n = 96 in the construct validity study) in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC) and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent face-to-face interview was assessed using ICC and percentage agreement. Of the 150 questionnaire items, 115 (77%) showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Test-retest reliability was moderate for 34 items (23%) and poor for one item. Construct validity appeared to be good to excellent for 70 (47%) of the 150 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 80 items, construct validity was moderate for 39 (26%) and poor for 41 items (27%). Our results demonstrate that the ENERGY-child questionnaire, assessing EBRBs of the child as well as personal, family, and school-environmental determinants related to these EBRBs, has good test-retest reliability and moderate to good construct validity for the large majority of items.

  18. Test-retest reliability and construct validity of the ENERGY-child questionnaire on energy balance-related behaviours and their potential determinants: the ENERGY-project

    PubMed Central

    2011-01-01

    Background Insight in children's energy balance-related behaviours (EBRBs) and their determinants is important to inform obesity prevention research. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. Objective To examine the test-retest reliability and construct validity of the child questionnaire used in the ENERGY-project, measuring EBRBs and their potential determinants among 10-12 year old children. Methods We collected data among 10-12 year old children (n = 730 in the test-retest reliability study; n = 96 in the construct validity study) in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC) and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent face-to-face interview was assessed using ICC and percentage agreement. Results Of the 150 questionnaire items, 115 (77%) showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Test-retest reliability was moderate for 34 items (23%) and poor for one item. Construct validity appeared to be good to excellent for 70 (47%) of the 150 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 80 items, construct validity was moderate for 39 (26%) and poor for 41 items (27%). Conclusions Our results demonstrate that the ENERGY-child questionnaire, assessing EBRBs of the child as well as personal, family, and school-environmental determinants related to these EBRBs, has good test-retest reliability and moderate to good construct validity for the large majority of items. PMID:22152048

  19. Review of a solution-processed vertical organic transistor as a solid-state vacuum tube

    NASA Astrophysics Data System (ADS)

    Lin, Hung-Cheng; Zan, Hsiao-Wen; Chao, Yu-Chiang; Chang, Ming-Yu; Meng, Hsin-Fei

    2015-05-01

    In this paper, we investigate the key issues in raising the on/off current ratio and increasing the output current. A 1 V operated inverter composed of an enhancement-mode space-charge-limited transistor (SCLT) and a depletion-mode SCLT is demonstrated using the self-assembled monolayer modulation process. With a bulk-conduction mechanism, good bias-stress reliability, and good bending durability are obtained. Finally, key scaling-up processes, including nanoimprinting and blade-coated nanospheres, are demonstrated.

  20. Validity and reliability of Internet-based physiotherapy assessment for musculoskeletal disorders: a systematic review.

    PubMed

    Mani, Suresh; Sharma, Shobha; Omar, Baharudin; Paungmali, Aatit; Joseph, Leonard

    2017-04-01

    Purpose The purpose of this review is to systematically explore and summarise the validity and reliability of telerehabilitation (TR)-based physiotherapy assessment for musculoskeletal disorders. Method A comprehensive systematic literature review was conducted using a number of electronic databases: PubMed, EMBASE, PsycINFO, Cochrane Library and CINAHL, published between January 2000 and May 2015. The studies examined the validity, inter- and intra-rater reliabilities of TR-based physiotherapy assessment for musculoskeletal conditions were included. Two independent reviewers used the Quality Appraisal Tool for studies of diagnostic Reliability (QAREL) and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool to assess the methodological quality of reliability and validity studies respectively. Results A total of 898 hits were achieved, of which 11 articles based on inclusion criteria were reviewed. Nine studies explored the concurrent validity, inter- and intra-rater reliabilities, while two studies examined only the concurrent validity. Reviewed studies were moderate to good in methodological quality. The physiotherapy assessments such as pain, swelling, range of motion, muscle strength, balance, gait and functional assessment demonstrated good concurrent validity. However, the reported concurrent validity of lumbar spine posture, special orthopaedic tests, neurodynamic tests and scar assessments ranged from low to moderate. Conclusion TR-based physiotherapy assessment was technically feasible with overall good concurrent validity and excellent reliability, except for lumbar spine posture, orthopaedic special tests, neurodynamic testa and scar assessment.

  1. Economic valuation by the method of paired comparison, with emphasis on evaluation of the transitivity axiom

    Treesearch

    George L. Peterson; Thomas C. Brown

    1998-01-01

    The paired comparison (PC) method is used to investigate reliability, transitivity, and decision time for binary choices among goods and sums of money. The PC method reveals inconsistent choices and yields individual preference order over the set of items being compared. The data reported support the transitivity assumption and demonstrate high reliability for...

  2. Further Validation of the Learning Alliance Inventory: The Roles of Working Alliance, Rapport, and Immediacy in Student Learning

    ERIC Educational Resources Information Center

    Rogers, Daniel T.

    2015-01-01

    This study further examined the reliability and validity of the Learning Alliance Inventory (LAI), a self-report measure designed to assess the working alliance between a student and a teacher. The LAI was found to have good internal consistency and test--retest reliability, and it demonstrated the predicted convergence with measures of immediacy…

  3. A comprehensive approach for diagnosing opportunities for improving the performance of a WWTP.

    PubMed

    Silva, C; Matos, J Saldanha; Rosa, M J

    2016-12-01

    High quality services of wastewater treatment require a continuous assessment and improvement of the technical, environmental and economic performance. This paper demonstrates a comprehensive approach for benchmarking wastewater treatment plants (WWTPs), using performance indicators (PIs) and indices (PXs), in a 'plan-do-check-act' cycle routine driven by objectives. The performance objectives herein illustrated were to diagnose the effectiveness and energy performance of an oxidation ditch WWTP. The PI and PX results demonstrated an effective and reliable oxidation ditch (good-excellent performance), and a non-reliable UV disinfection (unsatisfactory-excellent performance) related with influent transmittance and total suspended solids. The energy performance increased with the treated wastewater volume and was unsatisfactory below 50% of plant capacity utilization. The oxidation ditch aeration performed unsatisfactorily and represented 38% of the plant energy consumption. The results allowed diagnosing opportunities for improving the energy and economic performance considering the influent flows, temperature and concentrations, and for levering the WWTP performance to acceptable-good effectiveness, reliability and energy efficiency. Regarding the plant reliability for fecal coliforms, improvement of UV lamp maintenance and optimization of the UV dose applied and microscreen recommissioning were suggested.

  4. The Clinician-Administered PTSD Scale for DSM-5 (CAPS-5): Development and initial psychometric evaluation in military veterans.

    PubMed

    Weathers, Frank W; Bovin, Michelle J; Lee, Daniel J; Sloan, Denise M; Schnurr, Paula P; Kaloupek, Danny G; Keane, Terence M; Marx, Brian P

    2018-03-01

    The Clinician-Administered PTSD Scale (CAPS) is an extensively validated and widely used structured diagnostic interview for posttraumatic stress disorder (PTSD). The CAPS was recently revised to correspond with PTSD criteria in the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5; American Psychiatric Association, 2013). This article describes the development of the CAPS for DSM-5 (CAPS-5) and presents the results of an initial psychometric evaluation of CAPS-5 scores in 2 samples of military veterans (Ns = 165 and 207). CAPS-5 diagnosis demonstrated strong interrater reliability (к = .78 to 1.00, depending on the scoring rule) and test-retest reliability (к = .83), as well as strong correspondence with a diagnosis based on the CAPS for DSM-IV (CAPS-IV; к = .84 when optimally calibrated). CAPS-5 total severity score demonstrated high internal consistency (α = .88) and interrater reliability (ICC = .91) and good test-retest reliability (ICC = .78). It also demonstrated good convergent validity with total severity score on the CAPS-IV (r = .83) and PTSD Checklist for DSM-5 (r = .66) and good discriminant validity with measures of anxiety, depression, somatization, functional impairment, psychopathy, and alcohol abuse (rs = .02 to .54). Overall, these results indicate that the CAPS-5 is a psychometrically sound measure of DSM-5 PTSD diagnosis and symptom severity. Importantly, the CAPS-5 strongly corresponds with the CAPS-IV, which suggests that backward compatibility with the CAPS-IV was maintained and that the CAPS-5 provides continuity in evidence-based assessment of PTSD in the transition from DSM-IV to DSM-5 criteria. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. Multiple objective optimization in reliability demonstration test

    DOE PAGES

    Lu, Lu; Anderson-Cook, Christine Michaela; Li, Mingyang

    2016-10-01

    Reliability demonstration tests are usually performed in product design or validation processes to demonstrate whether a product meets specified requirements on reliability. For binomial demonstration tests, the zero-failure test has been most commonly used due to its simplicity and use of minimum sample size to achieve an acceptable consumer’s risk level. However, this test can often result in unacceptably high risk for producers as well as a low probability of passing the test even when the product has good reliability. This paper explicitly explores the interrelationship between multiple objectives that are commonly of interest when planning a demonstration test andmore » proposes structured decision-making procedures using a Pareto front approach for selecting an optimal test plan based on simultaneously balancing multiple criteria. Different strategies are suggested for scenarios with different user priorities and graphical tools are developed to help quantify the trade-offs between choices and to facilitate informed decision making. As a result, potential impacts of some subjective user inputs on the final decision are studied to offer insights and useful guidance for general applications.« less

  6. Reliability and Validity of Prototype Diagnosis for Adolescent Psychopathology.

    PubMed

    Haggerty, Greg; Zodan, Jennifer; Mehra, Ashwin; Zubair, Ayyan; Ghosh, Krishnendu; Siefert, Caleb J; Sinclair, Samuel J; DeFife, Jared

    2016-04-01

    The current study investigated the interrater reliability and validity of prototype ratings of 5 common adolescent psychiatric disorders: attention-deficit/hyperactivity disorder, conduct disorder, major depressive disorder, generalized anxiety disorder, and posttraumatic stress disorder. One hundred fifty-seven adolescent inpatient participants consented to participate in this study. We compared ratings from 2 inpatient clinicians, blinded to each other's ratings and patient measures, after their separate initial diagnostic interview to assess interrater reliability. Prototype ratings completed by clinicians after their initial diagnostic interview with adolescent inpatients and outpatients were compared with patient-reported behavior problems and parents' report of their child's behavioral problems. Prototype ratings demonstrated good interrater reliability. Clinicians' prototype ratings showed predicted relationships with patient-reported behavior problems and parent-reported behavior problems. Prototype matching seems to be a possible alternative for psychiatric diagnosis. Prototype ratings showed good interrater reliability based on clinicians unique experiences with the patient (as opposed to video-/audio-recorded material) with no training.

  7. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    PubMed

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  8. Reliability and Validity of Dual-Task Mobility Assessments in People with Chronic Stroke

    PubMed Central

    Yang, Lei; He, Chengqi; Pang, Marco Yiu Chung

    2016-01-01

    Background The ability to perform a cognitive task while walking simultaneously (dual-tasking) is important in real life. However, the psychometric properties of dual-task walking tests have not been well established in stroke. Objective To assess the test-retest reliability, concurrent and known-groups validity of various dual-task walking tests in people with chronic stroke. Design Observational measurement study with a test-retest design. Methods Eighty-eight individuals with chronic stroke participated. The testing protocol involved four walking tasks (walking forward at self-selected and maximal speed, walking backward at self-selected speed, and crossing over obstacles) performed simultaneously with each of the three attention-demanding tasks (verbal fluency, serial 3 subtractions or carrying a cup of water). For each dual-task condition, the time taken to complete the walking task, the correct response rate (CRR) of the cognitive task, and the dual-task effect (DTE) for the walking time and CRR were calculated. Forty-six of the participants were tested twice within 3–4 days to establish test-retest reliability. Results The walking time in various dual-task assessments demonstrated good to excellent reliability [Intraclass correlation coefficient (ICC2,1) = 0.70–0.93; relative minimal detectable change at 95% confidence level (MDC95%) = 29%-45%]. The reliability of the CRR (ICC2,1 = 0.58–0.81) and the DTE in walking time (ICC2,1 = 0.11–0.80) was more varied. The reliability of the DTE in CRR (ICC2,1 = -0.31–0.40) was poor to fair. The walking time and CRR obtained in various dual-task walking tests were moderately to strongly correlated with those of the dual-task Timed-up-and-Go test, thus demonstrating good concurrent validity. None of the tests could discriminate fallers (those who had sustained at least one fall in the past year) from non-fallers. Limitation The results are generalizable to community-dwelling individuals with chronic stroke only. Conclusions The walking time derived from the various dual-task assessments generally demonstrated good to excellent reliability, making them potentially useful in clinical practice and future research endeavors. However, the usefulness of these measurements in predicting falls needs to be further explored. Relatively low reliability was shown in the cognitive outcomes and DTE, which may not be preferred measurements for assessing dual-task performance. PMID:26808662

  9. A Multi-Domain Self-Report Measure of Coparenting

    PubMed Central

    Feinberg, Mark E.; Brown, Louis D.; Kan, Marni L.

    2012-01-01

    SYNOPSIS Objective This study reports the psychometric properties of a multi-domain measure of the coparenting relationship in dual-parent families. Method 152 couples participating in a transition to parenthood study completed the Coparenting Relationship Scale and additional measures during home visits at child age 6 months, 1 year, and 3 years. Results Psychometric and construct validity assessments indicated the measure performed satisfactorily. The 35-item measure demonstrated good reliability and strong stability. Subscales measuring theoretically and empirically important aspects of coparenting (coparenting agreement, coparenting closeness, exposure of child to conflict, coparenting support, coparenting undermining, endorsement of partner’s parenting, and division of labor) demonstrated good reliability as well. A 14-item brief overall measure showed very strong associations with the overall measure. Relations of the full scale with a measure of social desirability were weak, and the full scale was positively associated with positive dimensions of the dyadic couple relationship (love, sex/romance, couple efficacy) and inversely associated with negative dimensions (conflict, ineffective arguing)—as expected. Conclusions This initial examination of the Coparenting Relationship Scale suggests that it possesses good psychometric properties (reliability, stability, construct validity, and inter-rater agreement), can be flexibly administered in short and long forms, and is positioned to promote further conceptual and methodological progress in the study of coparenting. PMID:23166477

  10. Vestibular Assessments in Children With Global Developmental Delay: An Exploratory Study.

    PubMed

    Dannenbaum, Elizabeth; Horne, Victoria; Malik, Farwa; Villeneuve, Myriam; Salvo, Lora; Chilingaryan, Gevorg; Lamontagne, Anouk

    2016-01-01

    To compare results of 3 clinical vestibular tests between children with global developmental delay (GDD) and children with typical development (TD) and investigate the test-retest reliability. Twenty children with GDD (aged 4.1-12.1 years) and 11 age-matched controls with TD participated. Participants with GDD underwent 2 sessions of testing. Each session consisted of the Clinical Test of Sensory Interaction and Balance (CTSIB), Dynamic Visual Acuity (DVA) test, and the modified Emory Clinical Vestibular Chair Test (m-ECVCT). Up to 33% of the children with GDD had abnormal DVA scores. m-ECVCT results of children with GDD demonstrated larger variance than children with TD. The CTSIB score was significantly reduced in the group with GDD. The test-retest reliability varied, with good reliability for the m-ECVCT and CTSIB, and fair reliability for the DVA. Findings suggest vestibular involvement in children in GDD. The clinical tests demonstrated moderate test-retest reliability.

  11. The validity and reliability of Systemic Lupus Erythematosus Quality of Life Questionnaire (L-QoL) in a Turkish population.

    PubMed

    Duruöz, M T; Unal, C; Toprak, C Sanal; Sezer, I; Yilmaz, F; Ulutatar, F; Atagündüz, P; Baklacioglu, H S

    2017-12-01

    Background Systemic lupus erythematosus (SLE) may have a profound impact on quality of life. There is increasing interest in measuring quality of life in lupus patients. The purpose of this study was to investigate the validity and reliability of SLE Quality of Life Questionnaire (L-QoL) in Turkish SLE patients. Methods SLE according to 2012 Systemic Lupus International Collaborating Clinics Classification Criteria were recruited into the study. Demographic data, clinical parameters and disease activity measured with the Systemic Lupus Erythematosus Disease Activity Index-2000 (SLEDAI-2K); were noted. Nottingham Health Profile and Health Assessment Questionnaire were filled out in addition to the Turkish L-QoL (LQoL-TR). Internal consistency, test-retest reliability, and convergent and discriminant validity were evaluated. Results The mean age of participants was 43.55 ± 14.33 years and the mean disease duration was 89.8 ± 92.1 months. The patients filled out LQoL-TR in 2.5 min. Strong correlation of LQoL-TR with all subgroups of the Nottingham Health Profile and the Health Assessment Questionnaire were established showing the convergent validity. The highest correlation was demonstrated with emotional reactions (rho = 0.72) and sleep component (rho = 0.65) of the Nottingham Health Profile scale ( p < 0.0001). Its poor and not significant correlation with nonfunctional parameters (age, disease duration, perceived general health, SLEDAI-2K) showed its discriminative properties. LQoL-TR demonstrated good internal reliability with a Cronbach's α of 0.93 and test-retest reliability with intraclass correlation coefficient of 0.87. Conclusion The LQoL-TR is a practical and useful tool which demonstrates good validity and reliability.

  12. Psychometric Properties of Korean Version of the Second Victim Experience and Support Tool (K-SVEST).

    PubMed

    Kim, Eun-Mi; Kim, Sun-Aee; Lee, Ju-Ry; Burlison, Jonathan D; Oh, Eui Geum

    2018-02-13

    "Second victims" are defined as healthcare professionals whose wellness is influenced by adverse clinical events. The Second Victim Experience and Support Tool (SVEST) was used to measure the second-victim experience and quality of support resources. Although the reliability and validity of the original SVEST have been validated, those for the Korean tool have not been validated. The aim of the study was to evaluate the psychometric properties of the Korean version of the SVEST. The study included 305 clinical nurses as participants. The SVEST was translated into Korean via back translation. Content validity was assessed by seven experts, and test-retest reliability was evaluated by 30 clinicians. Internal consistency and construct validity were assessed via confirmatory factor analysis. The analyses were performed using SPSS 23.0 and STATA 13.0 software. The content validity index value demonstrated validity; item- and scale-level content validity index values were both 0.95. Test-retest reliability and internal consistency reliability were satisfactory: the intraclass consistent coefficient was 0.71, and Cronbach α values ranged from 0.59 to 0.87. The CFA showed a significantly good fit for an eight-factor structure (χ = 578.21, df = 303, comparative fit index = 0.92, Tucker-Lewis index = 0.90, root mean square error of approximation = 0.05). The K-SVEST demonstrated good psychometric properties and adequate validity and reliability. The results showed that the Korean version of SVEST demonstrated the extent of second victimhood and support resources in Korean healthcare workers and could aid in the development of support programs and evaluation of their effectiveness.

  13. 75 FR 70752 - Reliability Monitoring, Enforcement and Compliance Issues; Announcement of Panelists for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-18

    ... the Regional Entities set priorities of what to audit, and are they doing a good job setting priorities? Do audits focus too much on documentation? Would alternative auditing methods also demonstrate...

  14. A new real-time visual assessment method for faulty movement patterns during a jump-landing task.

    PubMed

    Rabin, Alon; Levi, Ran; Abramowitz, Shai; Kozol, Zvi

    2016-07-01

    Determine the interrater reliability of a new real-time assessment of faulty movement patterns during a jump-landing task. Interrater reliability study. Human movement laboratory. 50 healthy females. Assessment included 6 items which were evaluated from a front and a side view. Two Physical Therapy students used a 9-point scale (0-8) to independently rate the quality of movement as good (0-2), moderate (3-5), or poor (6-8). Interrater reliability was expressed by percent agreement and weighted kappa. One examiner rated the quality of movement of 6 subjects as good, 34 subjects as moderate, and 10 subjects as poor. The second examiner rated the quality of movement of 12 subjects as good, 23 subjects as moderate, and 15 subjects as poor. Percent agreement and weighted kappa (95% confidence interval) were 78% and 0.68 (0.51, 0.85), respectively. A new real-time assessment of faulty movement patterns during jump-landing demonstrated adequate interrater reliability. Further study is warranted to validate this method against a motion analysis system, as well as to establish its predictive validity for injury. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Positive prenatal well-being: conceptualising and measuring mindfulness and gratitude in pregnancy.

    PubMed

    O' Leary, Karen; Dockray, Samantha; Hammond, Sean

    2016-08-01

    Little research has examined the usefulness of positive well-being factors during pregnancy. Recent mindfulness research demonstrates that inconsistencies and the suitability of extant measures have yet to be examined in pregnancy. Effects of gratitude during pregnancy have yet to be examined despite consistently reported benefits in non-pregnant groups. The aims of this paper were to develop the Gratitude during Pregnancy (GDP) scale, validate the Mindfulness Awareness Attention Scale (MAAS) and examine the importance of gratitude and mindfulness during pregnancy. In study 1, 375 pregnant women completed gratitude and mindfulness measures. The one-factor structure of the MAAS was retained and demonstrated good reliability α = 0.88. Using exploratory factor analysis, an 18-item GDP scale was developed, demonstrating good reliability α = 0.89. The four GDP factors are as follows: general gratitude, physical changes, antenatal care and social support. In study 2, 87 pregnant women completed well-being questionnaires, including the GDP and MAAS. Gratitude correlated with positive affect, life satisfaction and pregnancy uplifts (p < .001); mindfulness correlated negatively with negative affect and pregnancy hassles (p < .001) and positively correlated with positive affect and pregnancy uplifts (p < .05). These findings highlight the importance of mindfulness and gratitude and provide a reliable means to measure both constructs during pregnancy.

  16. Neurobehavioural assessment and diagnosis in disorders of consciousness: a preliminary study of the Sensory Tool to Assess Responsiveness (STAR).

    PubMed

    Stokes, Verity; Gunn, Sarah; Schouwenaars, Katie; Badwan, Derar

    2018-09-01

    The Sensory Tool to Assess Responsiveness (STAR) is an interdisciplinary neurobehavioural diagnostic tool for individuals with prolonged disorders of consciousness. It utilises current diagnostic criteria and is intended to improve upon the high misdiagnosis rate in this population. This study assesses the inter-rater reliability of the STAR and its diagnostic validity in comparison with the Coma Recovery Scale-Revised (CRS-R) and the Wessex Head Injury Matrix (WHIM). Participants were patients with severe acquired brain injury resulting in a disorder of consciousness, who were admitted to the Royal Leamington Spa Rehabilitation Hospital between 1999 and 2009. Patients underwent sensory stimulation sessions during their period of admission, which were recorded on video. Using this footage, patients were re-assessed for this study using the STAR, WHIM and CRS-R criteria. The STAR demonstrated "moderate" inter-rater reliability, "substantial" diagnostic agreement with the CRS-R, and "moderate" agreement with the WHIM. There were no significant differences between diagnoses assigned by the different assessments. The STAR demonstrated a good degree of inter-rater reliability in identification of diagnoses for patients with disorders of consciousness. The diagnostic outcomes of the STAR agreed at a good level with the CRS-R, moderately with the WHIM, and did not significantly differ from either. This demonstrates the reliability and validity of the STAR, showing its appropriateness for clinical use. Future longitudinal studies and research into the STAR's applicability in long-stay rehabilitation are indicated.

  17. Motivational Interviewing Skills in Health Care Encounters (MISHCE): Development and psychometric testing of an assessment tool.

    PubMed

    Petrova, Tatjana; Kavookjian, Jan; Madson, Michael B; Dagley, John; Shannon, David; McDonough, Sharon K

    2015-01-01

    Motivational interviewing (MI) has demonstrated a significant impact as an intervention strategy for addiction management, change in lifestyle behaviors, and adherence to prescribed medication and other treatments. Key elements to studying MI include training in MI of professionals who will use it, assessment of skills acquisition in trainees, and the use of a validated skills assessment tool. The purpose of this research project was to develop a psychometrically valid and reliable tool that has been designed to assess MI skills competence in health care provider trainees. The goal was to develop an assessment tool that would evaluate the acquisition and use of specific MI skills and principles, as well as the quality of the patient-provider therapeutic alliance in brief health care encounters. To address this purpose, specific steps were followed, beginning with a literature review. This review contributed to the development of relevant conceptual and operational definitions, selecting a scaling technique and response format, and methods for analyzing validity and reliability. Internal consistency reliability was established on 88 video recorded interactions. The inter-rater and test-retest reliability were established using randomly selected 18 from the 88 interactions. The assessment tool Motivational Interviewing Skills for Health Care Encounters (MISHCE) and a manual for use of the tool were developed. Validity and reliability of MISHCE were examined. Face and content validity were supported with well-defined conceptual and operational definitions and feedback from an expert panel. Reliability was established through internal consistency, inter-rater reliability, and test-retest reliability. The overall internal consistency reliability (Cronbach's alpha) for all fifteen items was 0.75. MISHCE demonstrated good inter-rater reliability and good to excellent test-retest reliability. MISHCE assesses the health provider's level of knowledge and skills in brief disease management encounters. MISHCE also evaluates quality of the patient-provider therapeutic alliance, i.e., the "flow" of the interaction. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Reliability of instruments in a cooperative, multisite study: employment intervention demonstration program.

    PubMed

    Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T

    2001-09-01

    Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.

  19. Introducing the Professionalism Mini-Evaluation Exercise (P-MEX) in Japan: results from a multicenter, cross-sectional study.

    PubMed

    Tsugawa, Yusuke; Ohbu, Sadayoshi; Cruess, Richard; Cruess, Sylvia; Okubo, Tomoya; Takahashi, Osamu; Tokuda, Yasuharu; Heist, Brian S; Bito, Seiji; Itoh, Toshiyuki; Aoki, Akiko; Chiba, Tsutomu; Fukui, Tsuguya

    2011-08-01

    Despite the growing importance of and interest in medical professionalism, there is no standardized tool for its measurement. The authors sought to verify the validity, reliability, and generalizability of the Professionalism Mini-Evaluation Exercise (P-MEX), a previously developed and tested tool, in the context of Japanese hospitals. A multicenter, cross-sectional evaluation study was performed to investigate the validity, reliability, and generalizability of the P-MEX in seven Japanese hospitals. In 2009-2010, 378 evaluators (attending physicians, nurses, peers, and junior residents) completed 360-degree assessments of 165 residents and fellows using the P-MEX. The content validity and criterion-related validity were examined, and the construct validity of the P-MEX was investigated by performing confirmatory factor analysis through a structural equation model. The reliability was tested using generalizability analysis. The contents of the P-MEX achieved good acceptance in a preliminary working group, and the poststudy survey revealed that 302 (79.9%) evaluators rated the P-MEX items as appropriate, indicating good content validity. The correlation coefficient between P-MEX scores and external criteria was 0.78 (P < .001), demonstrating good criterion-related validity. Confirmatory factor analysis verified high path coefficient (0.60-0.99) and adequate goodness of fit of the model. The generalizability analysis yielded a high dependability coefficient, suggesting good reliability, except when evaluators were peers or junior residents. Findings show evidence of adequate validity, reliability, and generalizability of the P-MEX in Japanese hospital settings. The P-MEX is the only evaluation tool for medical professionalism verified in both a Western and East Asian cultural context.

  20. The development and validation of the Visual Analogue Self-Esteem Scale (VASES).

    PubMed

    Brumfitt, S M; Sheeran, P

    1999-11-01

    To develop a visual analogue measure of self-esteem and test its psychometric properties. Two correlational studies involving samples of university students and aphasic speakers. Two hundred and forty-three university students completed multiple measures of self-esteem, depression and anxiety as well as measures of transitory mood and social desirability (Study 1). Two samples of aphasic speakers (N = 14 and N = 20) completed the Visual Analogue Self-Esteem Scale (VASES), the Rosenberg (1965) self-esteem scale and measures of depression and anxiety. (Study 2). Study 1 found evidence of good internal and test-retest reliability, construct validity and convergent and discriminant validity for a 10-item VASES. Study 2 demonstrated good internal reliability among aphasic speakers. The VASES is a short and easy to administer measure of self-esteem that possesses good psychometric properties.

  1. Development and positioning reliability of a TMS coil holder for headache research.

    PubMed

    Chronicle, Edward P; Pearson, A Jane; Matthews, Cheryl

    2005-01-01

    Accurate and reproducible coil positioning is important for headache research using transcranial magnetic stimulation protocols. We aimed to design a transcranial magnetic stimulation coil holder and demonstrate reliability of test-retest coil positioning. A coil holder was developed and manufactured according to three principles of stability, durability, and three-dimensional positional accuracy. Reliability of coil positioning was assessed by stimulating over the motor cortex of four neurologically normal subjects and recording finger muscle responses, both at a test phase and a retest phase several hours later. In all four subjects, repositioning of the transcranial magnetic stimulation coil solely on the basis of coil holder coordinates was accurate to within 2 mm. The coil holder demonstrated good test-retest reliability of coil positioning, and is thus a promising tool for transcranial magnetic stimulation-based headache research, particularly studies of prophylactic drug effect where several laboratory visits with identical coil positioning are necessary.

  2. Assessment of a condition-specific quality-of-life measure for patients with developmentally absent teeth: validity and reliability testing.

    PubMed

    Akram, A J; Ireland, A J; Postlethwaite, K C; Sandy, J R; Jerreat, A S

    2013-11-01

    This article describes the process of validity and reliability testing of a condition-specific quality-of-life measure for patients with hypodontia presenting for orthodontic treatment. The development of the instrument is described in a previous article. Royal Devon and Exeter NHS Foundation Trust & Musgrove Park Hospital, Taunton. The child perception questionnaire was used as a standard against which to test criterion validity. The Bland and Altman method was used to check agreement between the two questionnaires. Construct validity was tested using principal component analysis on the four sections of the questionnaire. Test-retest reliability was tested using intraclass correlation coefficient and Bland and Altman method. Cronbach's alpha was used to test internal consistency reliability. Overall the questionnaire showed good reliability, criterion and construct validity. This together with previous evidence of good face and content validity suggests that the instrument may prove useful in clinical practice and further research. This study has demonstrated that the newly developed condition-specific quality-of-life questionnaire is both valid and reliable for use in young patients with hypodontia. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  3. Development and Validation of a Portable and Inexpensive Tool to Measure the Drop Vertical Jump Using the Microsoft Kinect V2.

    PubMed

    Gray, Aaron D; Willis, Brad W; Skubic, Marjorie; Huo, Zhiyu; Razu, Swithin; Sherman, Seth L; Guess, Trent M; Jahandar, Amirhossein; Gulbrandsen, Trevor R; Miller, Scott; Siesener, Nathan J

    Noncontact anterior cruciate ligament (ACL) injury in adolescent female athletes is an increasing problem. The knee-ankle separation ratio (KASR), calculated at initial contact (IC) and peak flexion (PF) during the drop vertical jump (DVJ), is a measure of dynamic knee valgus. The Microsoft Kinect V2 has shown promise as a reliable and valid marker-less motion capture device. The Kinect V2 will demonstrate good to excellent correlation between KASR results at IC and PF during the DVJ, as compared with a "gold standard" Vicon motion analysis system. Descriptive laboratory study. Level 2. Thirty-eight healthy volunteer subjects (20 male, 18 female) performed 5 DVJ trials, simultaneously measured by a Vicon MX-T40S system, 2 AMTI force platforms, and a Kinect V2 with customized software. A total of 190 jumps were completed. The KASR was calculated at IC and PF during the DVJ. The intraclass correlation coefficient (ICC) assessed the degree of KASR agreement between the Kinect and Vicon systems. The ICCs of the Kinect V2 and Vicon KASR at IC and PF were 0.84 and 0.95, respectively, showing excellent agreement between the 2 measures. The Kinect V2 successfully identified the KASR at PF and IC frames in 182 of 190 trials, demonstrating 95.8% reliability. The Kinect V2 demonstrated excellent ICC of the KASR at IC and PF during the DVJ when compared with the Vicon system. A customized Kinect V2 software program demonstrated good reliability in identifying the KASR at IC and PF during the DVJ. Reliable, valid, inexpensive, and efficient screening tools may improve the accessibility of motion analysis assessment of adolescent female athletes.

  4. Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise.

    PubMed

    Heres, H M; Schoots, T; Tchang, B C Y; Rutten, M C M; Kemps, H M C; van de Vosse, F N; Lopata, R G P

    2018-06-01

    Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test-retest reliability has been investigated. Fixation of the ultrasound probe on the upper leg allowed for continuous PDUS measurements. Cycling exercise protocols included a submaximal and an incremental exercise to maximal power. The relative perfused area (RPA) was determined as a measure of perfusion. Absolute and relative reliability of RPA amplitude and kinetic parameters during exercise (onset, slope, maximum value) and recovery (overshoot, decay time constants) were investigated. A RPA increase during exercise followed by a signal recovery was measured in all volunteers. Amplitudes and kinetic parameters during exercise and recovery showed poor to good relative reliability (ICC ranging from 0.2-0.8), and poor to moderate absolute reliability (coefficient of variation (CV) range 18-60%). A method has been demonstrated which allows for continuous (Power Doppler) ultrasonography and assessment of perfusion dynamics in skeletal muscle during exercise. The reliability of the RPA amplitudes and kinetics ranges from poor to good, while the reliability of the RPA increase in submaximal cycling (ICC = 0.8, CV = 18%) is promising for non-invasive clinical assessment of the muscle perfusion response to daily exercise.

  5. The reliability of the Associate Platinum digital foot scanner in measuring previously developed footprint characteristics: a technical note.

    PubMed

    Papuga, M Owen; Burke, Jeanmarie R

    2011-02-01

    An ink pad and paper, pressure-sensitive platforms, and photography have previously been used to collect footprint data used in clinical assessment. Digital scanners have been widely used more recently to collect such data. The purpose of this study was to evaluate the intra- and interrater reliability of a flatbed digital image scanning technology to capture footprint data. This study used a repeated-measures design on 32 (16 male 16 female) healthy subjects. The following measured indices of footprint were recorded from 2-dimensional images of the plantar surface of the foot recorded with an Associate Platinum (Foot Levelers Inc, Roanoke, VA) digital foot scanner: Staheli index, Chippaux-Smirak index, arch angle, and arch index. Intraclass correlation coefficient (ICC) values were calculated to evaluate intrarater, interday, and interclinician reliability. The ICC values for intrarater reliability were greater than or equal to .817, indicating an excellent level of reproducibility in assessing the collected images. Analyses of variance revealed that there were no significant differences between raters for each index (P > .05). The ICC values also indicated excellent reliability (.881-.971) between days and clinicians in all but one of the indices of footprint, arch angle (.689), with good reliability between clinicians. The full-factorial analysis of variance model did not reveal any interaction effects (P > .05), which indicated that indices of footprint were not changing across days and clinicians. Scanning technology used in this study demonstrated good intra- and interrater reliability measurements of footprint indices, as demonstrated by high ICC values. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  6. Testing the reliability of the Fall Risk Screening Tool in an elderly ambulatory population.

    PubMed

    Fielding, Susan J; McKay, Michael; Hyrkas, Kristiina

    2013-11-01

    To identify and test the reliability of a fall risk screening tool in an ambulatory outpatient clinic. The Fall Risk Screening Tool (Albert Lea Medical Center, MN, USA) was scripted for an interview format. Two interviewers separately screened a convenience sample of 111 patients (age ≥ 65 years) in an ambulatory outpatient clinic in a northeastern US city. The interviewers' scoring of fall risk categories was similar. There was good internal consistency (Cronbach's α = 0.834-0.889) and inter-rater reliability [intra-class correlation coefficients (ICC) = 0.824-0.881] for total, Risk Factor and Client's Health Status subscales. The Physical Environment scores indicated acceptable internal consistency (Cronbach's α = 0.742) and adequate reliability (ICC = 0.688). Two Physical Environment items (furniture and medical equipment condition) had low reliabilities [Kappa (K) = 0.323, P = 0.08; K = -0.078, P = 0.648), respectively. The scripted Fall Risk Screening Tool demonstrated good reliability in this sample. Rewording two Physical Environment items will be considered. A reliable instrument such as the scripted Fall Risk Screening Tool provides a standardised assessment for identifying high fall risk patients. This tool is especially useful because it assesses personal, behavioural and environmental factors specific to community-dwelling patients; the interview format also facilitates patient-provider interaction. © 2013 John Wiley & Sons Ltd.

  7. Measuring verbal and non-verbal communication in aphasia: reliability, validity, and sensitivity to change of the Scenario Test.

    PubMed

    van der Meulen, Ineke; van de Sandt-Koenderman, W Mieke E; Duivenvoorden, Hugo J; Ribbers, Gerard M

    2010-01-01

    This study explores the psychometric qualities of the Scenario Test, a new test to assess daily-life communication in severe aphasia. The test is innovative in that it: (1) examines the effectiveness of verbal and non-verbal communication; and (2) assesses patients' communication in an interactive setting, with a supportive communication partner. To determine the reliability, validity, and sensitivity to change of the Scenario Test and discuss its clinical value. The Scenario Test was administered to 122 persons with aphasia after stroke and to 25 non-aphasic controls. Analyses were performed for the entire group of persons with aphasia, as well as for a subgroup of persons unable to communicate verbally (n = 43). Reliability (internal consistency, test-retest reliability, inter-judge, and intra-judge reliability) and validity (internal validity, convergent validity, known-groups validity) and sensitivity to change were examined using standard psychometric methods. The Scenario Test showed high levels of reliability. Internal consistency (Cronbach's alpha = 0.96; item-rest correlations = 0.58-0.82) and test-retest reliability (ICC = 0.98) were high. Agreement between judges in total scores was good, as indicated by the high inter- and intra-judge reliability (ICC = 0.86-1.00). Agreement in scores on the individual items was also good (square-weighted kappa values 0.61-0.92). The test demonstrated good levels of validity. A principal component analysis for categorical data identified two dimensions, interpreted as general communication and communicative creativity. Correlations with three other instruments measuring communication in aphasia, that is, Spontaneous Speech interview from the Aachen Aphasia Test (AAT), Amsterdam-Nijmegen Everyday Language Test (ANELT), and Communicative Effectiveness Index (CETI), were moderate to strong (0.50-0.85) suggesting good convergent validity. Group differences were observed between persons with aphasia and non-aphasic controls, as well as between persons with aphasia unable to use speech to convey information and those able to communicate verbally; this indicates good known-groups validity. The test was sensitive to changes in performance, measured over a period of 6 months. The data support the reliability and validity of the Scenario Test as an instrument for examining daily-life communication in aphasia. The test focuses on multimodal communication; its psychometric qualities enable future studies on the effect of Alternative and Augmentative Communication (AAC) training in aphasia.

  8. Assessing the validity and reliability of the Pool Activity Level (PAL) Checklist for use with older people with dementia.

    PubMed

    Wenborn, Jennifer; Challis, David; Pool, Jackie; Burgess, Jane; Elliott, Nicola; Orrell, Martin

    2008-03-01

    Activity is key to maintaining physical and mental health and well-being. However, as dementia affects the ability to engage in activity, care-givers can find it difficult to provide appropriate activities. The Pool Activity Level (PAL) Checklist guides the selection of appropriate, personally meaningful activities. The aim of this study was to assess the reliability and validity of the PAL Checklist when used with older people with dementia. A postal questionnaire sent to activity providers assessed content validity. Validity and reliability were measured in a sample of 60 older people with dementia. The questionnaire response rate was 83% (102/122). Most respondents felt no important items were missing. Seven of the nine activities were ranked as 'very important' or 'essential' by at least 77% of the sample, indicating very good content validity. Correlation with measures of cognition, severity of dementia and activity performance demonstrated strong concurrent validity. Inter-item correlation indicated strong construct validity. Cronbach's alpha coefficient measured internal consistency as excellent (0.95). All items achieved acceptable test-retest reliability, and the majority demonstrated acceptable inter-rater reliability. We conclude that the PAL Checklist demonstrates adequate validity and reliability when used with older people with dementia and appears a useful tool for a variety of care settings.

  9. Validity and reliability of the Malay version multidimensional scale of perceived social support (MSPSS-M) among teachers.

    PubMed

    Lee, Soo Cheng; Moy, Foong Ming; Hairi, Noran Naqiah

    2017-01-01

    The multidimensional scale of perceived social support (MSPSS) was developed to measure perceived social support. It has been translated and culturally adapted among natives literate in the Malay language. However, its psychometric properties for teachers who are majority females and married have not been assessed. This was a cross-sectional study conducted among the public secondary school teachers in the central region of Peninsular Malaysia from May to July 2013. A total of 150 and 203 teachers were recruited to perform exploratory factor analysis and confirmatory factor analysis (CFA), respectively. Reliability testing was evaluated on 141 teachers via internal consistency and two-week interval test-retest. The 12-item three-factor structure of MSPSS-M was revised to 8-item two-factor structure. The revised MSPSS-M demonstrated excellent fit in CFA with adequate divergent and convergent validity and good factor loadings (0.80-0.90). The revised MSPSS-M also displayed good internal consistency with Cronbach's alpha of 0.91, 0.93 and 0.92 and good test-retest reliability with intraclass correlation of 0.89, 0.88 and 0.88 in the total scale, family and friends factors, respectively. The revised 8-item MSPSS-M is a reliable and valid tool for assessment of perceived social support among teachers.

  10. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    PubMed

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  11. Validation of an instrument to measure quality of life in British children with inflammatory bowel disease.

    PubMed

    Ogden, C A; Akobeng, A K; Abbott, J; Aggett, P; Sood, M R; Thomas, A G

    2011-09-01

    To validate IMPACT-III (UK), a health-related quality of life (HRQoL) instrument, in British children with inflammatory bowel disease (IBD). One hundred six children and parents were invited to participate. IMPACT-III (UK) was validated by inspection by health professionals and children to assess face and content validity, factor analysis to determine optimum domain structure, use of Cronbach alpha coefficients to test internal reliability, ANOVA to assess discriminant validity, correlation with the Child Health Questionnaire to assess concurrent validity, and use of intraclass correlation coefficients to assess test-retest reliability. The independent samples t test was used to measure differences between sexes and age groups, and between paper and computerised versions of IMPACT-III (UK). IMPACT-III (UK) had good face and content validity. The most robust factor solution was a 5-domain structure: body image, embarrassment, energy, IBD symptoms, and worries/concerns about IBD, all of which demonstrated good internal reliability (α = 0.74-0.88). Discriminant validity was demonstrated by significant (P  < 0.05, P < 0.01) differences in HRQoL scores between the severe, moderate, and inactive/mild symptom severity groups for the embarrassment scale (63.7 vs 81.0 vs 81.2), IBD symptom scale (45.0 vs 64.2 vs 80.6), and the energy scale (46.4 vs 62.1 vs 77.7). Concurrent validity of IMPACT-III (UK) with comparable domains of the Child Health Questionnaire was confirmed. Test-retest reliability was confirmed with good intraclass correlation coefficients of 0.66 to 0.84. Paper and computer versions of IMPACT-III (UK) collected comparable scores, and there were no differences between the sexes and age groups. IMPACT-III (UK) appears to be a useful tool to measure HRQoL in British children with IBD.

  12. Psychometric evaluation of the Chinese version of the Child Health Utility 9D (CHU9D-CHN): a school-based study in China.

    PubMed

    Yang, Peirong; Chen, Gang; Wang, Peng; Zhang, Kejian; Deng, Feng; Yang, Haifeng; Zhuang, Guihua

    2018-05-05

    The Child Health Utility 9D (CHU9D), a new generic preference-based health-related quality of life (HRQoL) instrument, was developed specifically for the application in cost-effectiveness analyses of treatments and interventions for children and adolescents. The main objective of this study was to examine the psychometric property of the Chinese version of CHU9D (CHU9D-CHN) in a large school-based sample in China. Data were collected using a multi-stage sampling method from third-to-ninth-grade students in Shaanxi Province, China. Participants self-completed a hard-copy questionnaire including the CHU9D-CHN instrument, the Pediatric Quality of Life Inventory™ 4.0 Generic Core Scales (PedsQL), information on socio-demographic characteristics and self-reported health status. The psychometric properties of the CHU9D-CHN, including the internal consistency, 2-week test-retest reliability, convergent and known-groups validity were studied. A total of 1912 students participated in the survey. The CHU9D-CHN internal consistency and test-retest reliability were good to excellent with a Cronbach's alpha of 0.77 and an intra-class correlation coefficient of 0.65, respectively. The CHU9D utility scores moderately correlated with the PedsQL total scores (r = .57, P < .001), demonstrating good convergent validity. Difference of the CHU9D utility scores among the different participants with levels of self-reported general health, health services utilisation and left-behind status demonstrated good construct validity. The findings demonstrated adequate psychometric performance for the CHU9D-CHN. The CHU9D-CHN was a satisfactory, reliable and valid instrument to measure and value HRQoL for children and adolescents in China.

  13. Spanish validation of the Person-centered Care Assessment Tool (P-CAT).

    PubMed

    Martínez, Teresa; Suárez-Álvarez, Javier; Yanguas, Javier; Muñiz, José

    2016-01-01

    Person-centered Care (PCC) is an innovative approach which seeks to improve the quality of care services given to the care-dependent elderly. At present there are no Spanish language instruments for the evaluation of PCC delivered by elderly care services. The aim of this work is the adaptation and validation of the Person-centered Care Assessment Tool (P-CAT) for a Spanish population. The P-CAT was translated and adapted into Spanish, then given to a sample of 1339 front-line care professionals from 56 residential elderly care homes. The reliability and validity of the P-CAT were analyzed, within the frameworks of Classical Test Theory and Item Response Theory models. The Spanish P-CAT demonstrated good reliability, with an alpha coefficient of .88 and a test-retest reliability coefficient of .79. The P-CAT information function indicates that the test measures with good precision for the majority of levels of the measured variables (θ values between -2 and +1). The factorial structure of the test is essentially one-dimensional and the item discrimination indices are high, with values between .26 and .61. In terms of predictive validity, the correlations which stand out are between the P-CAT and organizational climate (r = .689), and the burnout factors; personal accomplishment (r = .382), and emotional exhaustion (r = - .510). The Spanish version of the P-CAT demonstrates good psychometric properties for its use in the evaluation of elderly care homes both professionally and in research.

  14. The Overt Behaviour Scale-Self-Report (OBS-SR) for acquired brain injury: exploratory analysis of reliability and validity.

    PubMed

    Kelly, Glenn; Simpson, Grahame K; Brown, Suzanne; Kremer, Peter; Gillett, Lauren

    2017-05-23

    The objectives were to test the properties, via a psychometric study, of the Overt Behaviour Scale-Self-Report (OBS-SR), a version of the OBS-Adult Scale developed to provide a client perspective on challenging behaviours after acquired brain injury. Study sample 1 consisted of 37 patients with primary brain tumour (PBT) and a family-member informant. Sample 2 consisted of 34 clients with other acquired brain injury (mixed brain injury, MBI) and a service-provider informant. Participants completed the OBS-SR (at two time points), and the Awareness Questionnaire (AQ) and Mayo Portland Adaptability Inventory-III (MPAI-III) once; informants completed the OBS-Adult and AQ once only. PBT-informant dyads displayed "good" levels of agreement (ICC 2,k  = .74; OBS-SR global index). Although MBI-informant dyads displayed no agreement (ICC 2,k  = .22; OBS-SR global index), the sub-group (17/29) rated by clinicians as having moderate to good levels of awareness displayed "fair" agreement (ICC 2,k  = .58; OBS-SR global index). Convergent/divergent validity was demonstrated by significant correlations between OBS-SR subscales and MPAI-III subscales with behavioural content (coefficients in the range .36 -.61). Scores had good reliability across one week (ICC 2,k  = .69). The OBS-SR took approximately 15 minutes to complete. It was concluded that the OBS-SR demonstrated acceptable reliability and validity, providing a useful resource in understanding clients' perspectives about their behaviour.

  15. Translation and Initial Validation of the Japanese Version of the Self-Beliefs Related to Social Anxiety Scale.

    PubMed

    Maeda, Shunta; Shimada, Hironori; Sato, Tomoya; Tashiro, Kyoko; Tanaka, Yuki

    2017-04-01

    Cognitive models of social anxiety posit that there are several types of maladaptive beliefs responsible for persistent social anxiety. Although these beliefs are theoretically important, currently there is no validated measure of these beliefs in Japan. In the present study, we translated into Japanese a well-validated measure of these beliefs, the Self-Beliefs Related to Social Anxiety (SBSA) Scale. The psychometric properties of the scale were also examined in two nonclinical samples ( ns = 401 and 30). Using confirmatory factor analysis, the Japanese version of the SBSA was found to have a correlated three-factor structure that consisted of "conditional beliefs," "unconditional beliefs," and "high standard beliefs." In addition, the Japanese version of the SBSA and its subscales demonstrated good internal consistency reliability and test-retest reliability. The Japanese version of the SBSA also demonstrated good convergent and divergent validity. Future applications of the Japanese version of the SBSA are discussed.

  16. Reliability and validity of urinary nerve growth factor measurement in women with lower urinary tract symptoms.

    PubMed

    Vijaya, Gopalan; Cartwright, Rufus; Bhide, Alka; Derpapas, Alexandros; Fernando, Ruwan; Khullar, Vik

    2016-11-01

    The validity and reliability of measurement of urinary NGF as a diagnostic biomarker in women with lower urinary tract dysfunction (LUTD) is uncertain. We aimed to evaluate both the diagnostic and discriminant validity, and the test-retest reliability of urinary NGF measurement in women with LUTD. Urinary NGF was measured in women with LUTD (n = 205) and asymptomatic subjects (n = 31). Urinary NGF was assayed using an ELISA method and normalized against urinary creatinine. NGF/creatinine ratios were compared between symptom subgroups using Mann-Whitney U test, and between different urodynamic diagnoses using the Kruskal-Wallis test. Receiver Operator Characteristic (ROC) analysis was employed to evaluate the diagnostic performance of urinary NGF. Test-retest reliability of NGF measurement was assessed using intra-class correlation (ICC). Urinary NGF was significantly but non-specifically increased in symptomatic patients when compared to controls (13.33 vs. 2.05 ng NGF/g Cr, P < 0.001). On multivariate logistic regression NGF was a good predictor of patients having OAB or not, however, the adjusted odds ratio only 1.006. ROC analysis demonstrated poor discriminant ability between different symptomatic groups and urodynamic groups. Using a cut off of 13.0 ng NGF/g creatinine the test provides a sensitivity of 81%, but a specificity of only 39% for overactive bladder. The assays demonstrated good test-retest reliability with ICC of 0.889. Although urinary NGF can be reliably assayed, and is increased in various LUTDs, it discriminates poorly between these disorders therefore has very limited potential as a biomarker. Neurourol. Urodynam. 35:944-948, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  17. Questionnaire for measuring organisational attributes in dental-care practices: psychometric properties and test-retest reliability.

    PubMed

    Goetz, Katja; Hasse, Philipp; Szecsenyi, Joachim; Campbell, Stephen M

    2016-04-01

    The consideration of organisational aspects, such as shared goals and clear communication, within the health care team is important to ensure good quality care. In primary health care, the instrument Survey of Organizational Attributes for Primary Care (SOAPC) is available to measure organisational attributes of care. However, there is no instrument available for dental care. The aim of the present study was to investigate psychometric properties and test-retest reliability of the version of SOAPC adapted for dental care, namely the Survey of Organizational Attributes in Dental Care (SOADC). The SOADC consists of 21 items in the following four subscales: communication; decision making; stress/chaos; and history of change. Convergent construct validity was measured using the job satisfaction scale. A total of 287 dental-care practices were asked to participate in the validation study. Psychometric properties and test-retest reliability were observed. A total of 43 dental-care practices responded to the survey. At baseline, 178 dental-care staff completed the questionnaire, and 4 weeks later 138 did so. Internal consistency, measured by Cronbach's alpha, was 0.718 or higher in the subscales. The test-retest reliability for each subscale and the overall SOADC score demonstrated good correlations over the 4-week test-retest interval, except for 'history of change'. A strong correlation with the aggregated job-satisfaction scale showed high convergent construct validity of SOADC. The consideration of organisational aspects from the perspective of dental-care teams is important for providing good quality of care. The SOADC is a reliable instrument with good psychometric properties and is suitable for the evaluation of organisational attributes in dental-care practices. © 2015 FDI World Dental Federation.

  18. Fatigue in children: reliability and validity of the Dutch PedsQL™ Multidimensional Fatigue Scale.

    PubMed

    Gordijn, M Suzanne; Suzanne Gordijn, M; Cremers, Eline M P; Kaspers, Gertjan J L; Gemke, Reinoud J B J

    2011-09-01

    The aim of the study is to report on the feasibility, reliability, validity, and the norm-references of the Dutch version of the PedsQL™ Multidimensional Fatigue Scale. The study participants are four hundred and ninety-seven parents of children aged 2-18 years and 366 children aged 5-18 years from various day care facilities, elementary schools, and a high school who completed the Dutch version of the PedsQL™ Multidimensional Fatigue Scale. The number of missing items was minimal. All scales showed satisfactory internal consistency reliability, with Cronbach's coefficient alpha exceeding 0.70. Test-retest reliability was good to excellent (ICCs 0.68-0.84) and inter-observer reliability varied from moderate to excellent (ICCs 0.56-0.93) for total scores. Parent/child concordance for total scores was poor to good (ICCs 0.25-0.68). The PedsQL™ Multidimensional Fatigue Scale was able to distinguish between healthy children and children with an impaired health condition. The Dutch version of the PedsQL™ Multidimensional Fatigue Scale demonstrates an adequate feasibility, reliability, and validity in another sociocultural context. With the obtained norm-references, it can be utilized as a tool in the evaluation of fatigue in healthy and chronically ill children aged 2-18 years.

  19. Reliability and validity of a questionnaire for self-assessment of complete dentures.

    PubMed

    Komagamine, Yuriko; Kanazawa, Manabu; Kaiba, Yoshinori; Sato, Yusuke; Minakuchi, Shunsuke

    2014-05-02

    Demand for complete denture treatment is expected to rise over several decades. However, to date, no questionnaire on complete dentures, as evaluated by edentulous patients, has been shown to be reliable and valid. This study sought to assess the reliability and validity of Patient's Denture Assessment (PDA), which provides a multidimensional evaluation of dentures among edentulous patients. Patients, who had new complete dentures fabricated at the University Hospital of Dentistry, Tokyo Medical and Dental University through 2009 to 2010, were enrolled. The reliability of the PDA was determined by examining internal consistency and test-retest reliability. Internal consistency for all of the question items and the six subscales was measured using Cronbach's α and average inter-item correlation coefficients among 93 participants. For 33 of these participants, test-retest reliability was determined at a 2 month-interval using the interclass correlation coefficients (ICCs) and 95% confidence interval for the summary scores and the six subscale scores. The PDA was validated in 93 participants by examining the difference in the summary score and the six subscale scores of the PDA before and after replacement with new dentures by the paired t-test. Ability to detect change was also tested in 93 patients using effect size. The Cronbach's α for the PDA ranged from 0.56 to 0.93. The average inter-item correlation coefficients ranged from 0.28 to 0.83. ICCs for the PDA ranged from 0.37 to 0.83. The paired t-test showed a significant difference between the summary score and the six subscale scores before and after replacement with new dentures (p < 0.05) and the effect size was 0.97. The PDA demonstrated good reliability by assessing internal consistency and test-retest reliability. In addition, the PDA demonstrated good validity by assessing discriminant validity. Thus, the PDA could help dentists obtain a detailed understanding of the patients' perceptions in using their dentures.

  20. Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.

    PubMed

    Saner, Robert J; Washabaugh, Edward P; Krishnan, Chandramouli

    2017-07-01

    Three-dimensional (3-D) motion capture systems are commonly used for gait analysis because they provide reliable and accurate measurements. However, the downside of this approach is that it is expensive and requires technical expertise; thus making it less feasible in the clinic. To address this limitation, we recently developed and validated (using a high-precision walking robot) a low-cost, two-dimensional (2-D) real-time motion tracking approach using a simple webcam and LabVIEW Vision Assistant. The purpose of this study was to establish the repeatability and minimal detectable change values of hip and knee sagittal plane gait kinematics recorded using this system. Twenty-one healthy subjects underwent two kinematic assessments while walking on a treadmill at a range of gait velocities. Intraclass correlation coefficients (ICC) and minimal detectable change (MDC) values were calculated for commonly used hip and knee kinematic parameters to demonstrate the reliability of the system. Additionally, Bland-Altman plots were generated to examine the agreement between the measurements recorded on two different days. The system demonstrated good to excellent reliability (ICC>0.75) for all the gait parameters tested on this study. The MDC values were typically low (<5°) for most of the parameters. The Bland-Altman plots indicated that there was no systematic error or bias in kinematic measurements and showed good agreement between measurements obtained on two different days. These results indicate that kinematic gait assessments using webcam technology can be reliably used for clinical and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The Reliability and Validity of the Thoracolumbar Injury Classification System in Pediatric Spine Trauma.

    PubMed

    Savage, Jason W; Moore, Timothy A; Arnold, Paul M; Thakur, Nikhil; Hsu, Wellington K; Patel, Alpesh A; McCarthy, Kathryn; Schroeder, Gregory D; Vaccaro, Alexander R; Dimar, John R; Anderson, Paul A

    2015-09-15

    The thoracolumbar injury classification system (TLICS) was evaluated in 20 consecutive pediatric spine trauma cases. The purpose of this study was to determine the reliability and validity of the TLICS in pediatric spine trauma. The TLICS was developed to improve the categorization and management of thoracolumbar trauma. TLICS has been shown to have good reliability and validity in the adult population. The clinical and radiographical findings of 20 pediatric thoracolumbar fractures were prospectively presented to 20 surgeons with disparate levels of training and experience with spinal trauma. These injuries were consecutively scored using the TLICS. Cohen unweighted κ coefficients and Spearman rank order correlation values were calculated for the key parameters (injury morphology, status of posterior ligamentous complex, neurological status, TLICS total score, and proposed management) to assess the inter-rater reliabilities. Five surgeons scored the same cases 3 months later to assess the intra-rater reliability. The actual management of each case was then compared with the treatment recommended by the TLICS algorithm to assess validity. The inter-rater κ statistics of all subgroups (injury morphology, status of the posterior ligamentous complex, neurological status, TLICS total score, and proposed treatment) were within the range of moderate to substantial reproducibility (0.524-0.958). All subgroups had excellent intra-rater reliability (0.748-1.000). The various indices for validity were calculated (80.3% correct, 0.836 sensitivity, 0.785 specificity, 0.676 positive predictive value, 0.899 negative predictive value). Overall, TLICS demonstrated good validity. The TLICS has good reliability and validity when used in the pediatric population. The inter-rater reliability of predicting management and indices for validity are lower than those in adults with thoracolumbar fractures, which is likely due to differences in the way children are treated for certain types of injuries. TLICS can be used to reliably categorize thoracolumbar injuries in the pediatric population; however, modifications may be needed to better guide treatment in this specific patient population. 4.

  2. Validity and reliability of the Japanese version of the FIM + FAM in patients with cerebrovascular accident.

    PubMed

    Miki, Emi; Yamane, Shingo; Yamaoka, Mai; Fujii, Hiroe; Ueno, Hiroka; Kawahara, Toshie; Tanaka, Keiko; Tamashiro, Hiroaki; Inoue, Eiji; Okamoto, Takatsugu; Kuriyama, Masaru

    2016-09-01

    The study aim was to investigate the validity and reliability of the Functional Independence Measure and Functional Assessment Measure (FIM + FAM), which is unfamiliar in Japan, by using its Japanese version (FIM + FAM-j) in patients with cerebrovascular accident (CVA). Forty-two CVA patients participated. Criterion validity was examined by correlating the full scale and subscales of FIM + FAM-j with several well-established measurements using Spearman's correlation coefficient. Reliability was evaluated by internal consistency (tested by Cronbach's alpha coefficient) and intra-rater reliability (tested by Kendall's tau correlation coefficient). Good-to-excellent criterion validity was found between the full scale and motor subscales of the FIM + FAM-j and the Barthel Index, National Institutes of Health Stroke Scale, modified Rankin Scale, and lower extremity Brunnstrom Recovery Stage. High internal consistency was observed within the full-scale FIM + FAM-j and the motor and cognitive subscales (Cronbach's alphas were 0.968, 0.954, and 0.948, respectively). Additionally, good intra-rater reliability was observed within the full scale and motor subscales, and excellent reliability for the cognitive subscales (taus were 0.83, 0.80, and 0.98, respectively). This study showed that the FIM + FAM-j demonstrated acceptable levels of validity and reliability when used for CVA as a measure of disability.

  3. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    PubMed

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (p< 0.05), suggesting a good relationship between the two core stability measures. Test-retest reliability was (ICC3,3) = 0.953 (p< 0.05), indicating excellent consistency between the repeated DNS-HS measurements. Criterion validity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  4. Non-Technical Skills for Surgeons (NOTSS): Critical appraisal of its measurement properties.

    PubMed

    Jung, James J; Borkhoff, Cornelia M; Jüni, Peter; Grantcharov, Teodor P

    2018-02-17

    To critically appraise the development and measurement properties, including sensibility, reliability, and validity of the Non-Technical Skills of Surgeons (NOTSS) system. Articles that described development process of the NOTSS system were identified. Relevant primary studies that presented evidence of reliability and validity were identified through a comprehensive literature review. NOTSS was developed through robust item generation and reduction strategies. It was shown to have good content validity, acceptability, and feasibility. Inter-rater reliability increased with greater expertise and number of assessors. Studies demonstrated evidence of cross-sectional construct validity, in that the tool was able to differentiate known groups of varied non-technical skill levels. Evidence of longitudinal construct validity also existed to demonstrate that NOTSS detected changes in non-technical skills before and after targeted training. In populations and settings presented in our critical appraisal, NOTSS provided reliable and valid measurements of intraoperative non-technical skills of surgeons. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Reliability, validity and responsiveness of the German Manchester-Oxford Foot Questionnaire (MOXFQ) in patients with foot or ankle surgery.

    PubMed

    Arbab, Dariusch; Kuhlmann, Katharina; Ringendahl, Hubert; Bouillon, Bertil; Eysel, Peer; König, Dietmar

    2017-06-13

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopaedic procedures. The intention of this study was to develop and culturally adapt a German version of the Manchester-Oxford Foot Questionnaire (MOXFQ) and to evaluate reliability, validity and responsiveness. According to guidelines forward and backward translation has been performed. The German MOXFQ was investigated in 177 consecutive patients before and 6 months after foot or ankle surgery. All patients completed MOXFQ, Foot and Ankle Outcome Score (FAOS), Short form 36 and numeric scales for pain and disability (NRS). Test-Retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German MOXFQ demonstrated excellent test-retest reliability with ICC values >0.9 Cronbach's alpha (α) values demonstrated strong internal consistency. No floor or ceiling effects were observed. As hypothesized MOXFQ subscales correlated strongly with corresponding FAOS and SF-36 domains. All subscales showed excellent (ES/SRM >0.8) responsiveness between preoperative assessment and postoperative follow-up. The German version of the MOXFQ demonstrated good psychometric properties. It proofed to be a valid and reliable instrument for use in foot and ankle patients. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  6. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue

    PubMed Central

    Troester, Jordan C.; Jasmin, Jason G.; Duffield, Rob

    2018-01-01

    The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test – re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union. Key points Single-leg balance demonstrated acceptable inter-trial and inter-test reliability. Single-leg landing demonstrated good inter-trial and inter-test reliability for measures of relative peak landing force and relative impulse, but not time to stabilization. Of the variables investigated, sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing respectively, and should considered for monitoring changes in postural control. PMID:29769817

  7. Psychometric Properties of the "Miranda Rights Comprehension Instruments" with a Juvenile Justice Sample

    ERIC Educational Resources Information Center

    Goldstein, Naomi E. Sevin; Romaine, Christina L. Riggs; Zelle, Heather; Kalbeitzer, Rachel; Mesiarik, Constance; Wolbransky, Melinda

    2011-01-01

    This article describes the psychometric properties of the "Miranda Rights Comprehension Instruments", the revised version of Grisso's "Miranda" instruments. The original instruments demonstrated good reliability and validity in a normative sample. The revised instruments updated the content of the original instruments and were…

  8. Initial Development and Validation of the BullyHARM: The Bullying, Harassment, and Aggression Receipt Measure.

    PubMed

    Hall, William J

    2016-11-01

    This article describes the development and preliminary validation of the Bullying, Harassment, and Aggression Receipt Measure (BullyHARM). The development of the BullyHARM involved a number of steps and methods, including a literature review, expert review, cognitive testing, readability testing, data collection from a large sample, reliability testing, and confirmatory factor analysis. A sample of 275 middle school students was used to examine the psychometric properties and factor structure of the BullyHARM, which consists of 22 items and 6 subscales: physical bullying, verbal bullying, social/relational bullying, cyber-bullying, property bullying, and sexual bullying. First-order and second-order factor models were evaluated. Results demonstrate that the first-order factor model had superior fit. Results of reliability testing indicate that the BullyHARM scale and subscales have very good internal consistency reliability. Findings indicate that the BullyHARM has good properties regarding content validation and respondent-related validation and is a promising instrument for measuring bullying victimization in school.

  9. Cross-cultural adaptation, validation, and reliability of the Michigan Hand Outcomes Questionnaire among Persian population.

    PubMed

    Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Kachooei, Amir Reza

    2015-01-01

    We aimed to validate a cross-culturally adapted version of the Persian Michigan Hand Outcomes Questionnaire (MHOQ). We followed the Beaton's guideline to translate the questionnaire to Persian. We administered the final version to 223 patients among which 79 patients returned 3 days later to respond to the Persian MHOQ for the second time. In the first visit, respondents also filled the Disabilities of the Arm Shoulder and Hand (DASH) and rated the pain based on the Visual Analogue Scale (VAS). Cronbach's alpha for the total MHOQ was 0.79 which showed good internal consistency. Intraclass correlation coefficient (ICC) for the total MHOQ was 0.84 which demonstrated good reliability between test and retest. The absolute correlation coefficient between total MHOQ and the DASH was as high as 0.74. Persian version of the MHOQ proved to be a reliable and valid instrument to be implemented among Persian population with the hand and wrist disorders.

  10. Initial Development and Validation of the BullyHARM: The Bullying, Harassment, and Aggression Receipt Measure

    PubMed Central

    Hall, William J.

    2017-01-01

    This article describes the development and preliminary validation of the Bullying, Harassment, and Aggression Receipt Measure (BullyHARM). The development of the BullyHARM involved a number of steps and methods, including a literature review, expert review, cognitive testing, readability testing, data collection from a large sample, reliability testing, and confirmatory factor analysis. A sample of 275 middle school students was used to examine the psychometric properties and factor structure of the BullyHARM, which consists of 22 items and 6 subscales: physical bullying, verbal bullying, social/relational bullying, cyber-bullying, property bullying, and sexual bullying. First-order and second-order factor models were evaluated. Results demonstrate that the first-order factor model had superior fit. Results of reliability testing indicate that the BullyHARM scale and subscales have very good internal consistency reliability. Findings indicate that the BullyHARM has good properties regarding content validation and respondent-related validation and is a promising instrument for measuring bullying victimization in school. PMID:28194041

  11. Good reliability and validity for a new utility instrument measuring the birth experience, the Labor and Delivery Index.

    PubMed

    Gärtner, Fania R; de Miranda, Esteriek; Rijnders, Marlies E; Freeman, Liv M; Middeldorp, Johanna M; Bloemenkamp, Kitty W M; Stiggelbout, Anne M; van den Akker-van Marle, M Elske

    2015-10-01

    To validate the Labor and Delivery Index (LADY-X), a new delivery-specific utility measure. In a test-retest design, women were surveyed online, 6 to 8 weeks postpartum and again 1 to 2 weeks later. For reliability testing, we assessed the standard error of measurement (S.E.M.) and the intraclass correlation coefficient (ICC). For construct validity, we tested hypotheses on the association with comparison instruments (Mackey Childbirth Satisfaction Rating Scale and Wijma Delivery Experience Questionnaire), both on domain and total score levels. We assessed known-group differences using eight obstetrical indicators: method and place of birth, induction, transfer, control over pain medication, complications concerning mother and child, and experienced control. The questionnaire was completed by 308 women, 257 (83%) completed the retest. The distribution of LADY-X scores was skewed. The reliability was good, as the ICC exceeded 0.80 and the S.E.M. was 0.76. Requirements for good construct validity were fulfilled: all hypotheses for convergent and divergent validity were confirmed, and six of eight hypotheses for known-group differences were confirmed as all differences were statistically significant (P-values: <0.001-0.023), but for two tests, difference scores did not exceed the S.E.M. The LADY-X demonstrates good reliability and construct validity. Despite its skewed distribution, the LADY-X can discriminate between groups. With the preference weights available, the LADY-X might fulfill the need for a utility measure for cost-effectiveness studies for perinatal care interventions. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists.

    PubMed

    Moran, Robert W; Rushworth, Wendy M; Mason, Jesse

    2017-12-01

    Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p < 0.001) demonstrated good convergent validity. There was a medium to large effect (Cohen's d > 0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Validity and reliability of the NAB Naming Test.

    PubMed

    Sachs, Bonnie C; Rush, Beth K; Pedraza, Otto

    2016-05-01

    Confrontation naming is commonly assessed in neuropsychological practice, but few standardized measures of naming exist and those that do are susceptible to the effects of education and culture. The Neuropsychological Assessment Battery (NAB) Naming Test is a 31-item measure used to assess confrontation naming. Despite adequate psychometric information provided by the test publisher, there has been limited independent validation of the test. In this study, we investigated the convergent and discriminant validity, internal consistency, and alternate forms reliability of the NAB Naming Test in a sample of adults (Form 1: n = 247, Form 2: n = 151) clinically referred for neuropsychological evaluation. Results indicate adequate-to-good internal consistency and alternate forms reliability. We also found strong convergent validity as demonstrated by relationships with other neurocognitive measures. We found preliminary evidence that the NAB Naming Test demonstrates a more pronounced ceiling effect than other commonly used measures of naming. To our knowledge, this represents the largest published independent validation study of the NAB Naming Test in a clinical sample. Our findings suggest that the NAB Naming Test demonstrates adequate validity and reliability and merits consideration in the test arsenal of clinical neuropsychologists.

  14. Assessment of the severity of dementia: validity and reliability of the Chinese (Cantonese) version of the Hierarchic Dementia Scale (CV-HDS).

    PubMed

    Poon, Vickie Wan-kei; Lam, Linda Chiu-wa; Wong, Samuel Yeung-shan

    2008-09-01

    With the rapid growth of the older population, early detection of cognitive deficits is crucial in slowing down functional deterioration of the elderly persons. To examine the validity and reliability of the Chinese (Cantonese) version of the Hierarchic Dementia Scale (CV-HDS) for Chinese older persons in Hong Kong. The HDS was translated into Cantonese Chinese. The content and cultural validity were evaluated by six expert panel members. Sixty-two participants with diagnosis of dementia were recruited for evaluation. Inter-rater reliability, test-retest reliability, internal consistency and concurrent validity were examined. The CV-HDS demonstrated satisfactory psychometric properties. inter-rater reliability and test-retest reliability were high (alpha=0.89 and alpha=0.94 respectively). High value of Cronbach's alpha (alpha=0.94) demonstrated good internal consistency. The concurrent validity of CV-HDS, through correlation with its scores with that of the Chinese version of Mini Mental Status Examination, was established (ranged from r=0.58 to r=0.78, p<0.01). The CV-HDS is a reliable and valid instrument for assessing severity of cognitive impairment in Cantonese speaking Chinese people with dementia. It facilitates treatment planning to optimize the effects of functional training and rehabilitation.

  15. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    PubMed

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  16. Validation of the Persian version of the dysphagia handicap index in patients with neurological disorders

    PubMed Central

    Barzegar-Bafrooei, Ebrahim; Bakhtiary, Jalal; Khatoonabadi, Ahmad Reza; Fatehi, Farzad; Maroufizadeh, Saman; Fathali, Mojtaba

    2016-01-01

    Background: Dysphagia as a common condition affecting many aspects of the patient’s life. The Dysphagia Handicap Index (DHI) is a reliable self-reported questionnaire developed specifically to measure the impact of dysphagia on the patient’s quality of life. The aim of this study was to translate the questionnaire to Persian and to measure its validity and reliability in patients with neurogenic oropharyngeal dysphagia. Methods: A formal forward-backward translation of DHI was performed based on the guidelines for the cross-cultural adaptation of self-report measures. A total of 57 patients with neurogenic dysphagia who were referred to the neurology clinics of Tehran University of Medical Sciences, Iran, participated in this study. Internal consistency reliability of the DHI was examined using Cronbach’s alpha, and test-retest reliability of the scale was evaluated using intraclass correlation coefficient (ICC). Results: The internal consistency of the Persian DHI (P-DHI) was considered to be good; Cronbach’s alpha coefficient for the total P-DHI was 0.88. The test-retest reliability for the total and three subscales of the P-DHI ranged from 0.95 to 0.98 using ICC. Conclusion: The P-DHI demonstrated a good reliability, and it can be a valid instrument for evaluating the dysphagia effects on quality of life among Persian language population. PMID:27648173

  17. Development of a Chinese Version of the Suicide Intent Scale

    ERIC Educational Resources Information Center

    Gau, Susan S. F.; Chen, Chin-Hung; Lee, Charles T. C.; Chang, Jung-Chen; Cheng, Andrew T. A.

    2009-01-01

    This study established the psychometric properties of the Chinese version of the Suicide Intent Scale (SIS) in a clinic- and community-based sample of 36 patients and 592 respondents, respectively. Results showed that the Chinese SIS demonstrated good inter-rater and test-retest reliability. Factor analysis generated three factors (Precautions,…

  18. Validation of the Persian Version of the Problematic Internet Use Questionnaire (PIUQ).

    PubMed

    Ranjbar, Hadi; Thatcher, Andrew; Greyling, Michael; Arab, Mansour; Nasri, Nahid

    2014-10-01

    The most commonly used instrument for the research and treatment of excessive internet use is Young's Internet Addiction Test (IAT). While the IAT has been translated to several languages (including Persian) and has demonstrated good psychometric properties across several independent studies, there is still a room for alternative assessment instruments. This study reports a validation of the Persian version of the Problematic Internet Use Questionnaire (PIUQ). A sample (n = 296) from Kerman, Iran was administered the translated Persian version of the PIUQ as well as the Persian version of the University of California, Los Angeles (UCLA) Loneliness scale, Satisfaction With Life scale, and questions related to use of technology and the internet. Analyses using confirmatory and exploratory factor analyses demonstrated that the Persian version of the PIUQ had good internal reliability and concurrent validity (with loneliness and satisfaction with life), but they also had an alternative factor structure that did not support the original factor structure. The Persian version of the PIUQ produced adequate psychometric properties (internal reliability and concurrent validity), but care should be taken in the interpretation of the factor structure.

  19. Developing and validating the Communication Function Classification System for individuals with cerebral palsy

    PubMed Central

    HIDECKER, MARY JO COOLEY; PANETH, NIGEL; ROSENBAUM, PETER L; KENT, RAYMOND D; LILLIE, JANET; EULENBERG, JOHN B; CHESTER, KEN; JOHNSON, BRENDA; MICHALSEN, LAUREN; EVATT, MORGAN; TAYLOR, KARA

    2011-01-01

    Aim The purpose of this study was to create and validate a Communication Function Classification System (CFCS) for children with cerebral palsy (CP) that can be used by a wide variety of individuals who are interested in CP. This paper reports the content validity, interrater reliability, and test–retest reliability of the CFCS for children with CP. Method An 11-member development team created comprehensive descriptions of the CFCS levels, and four nominal groups comprising 27 participants critiqued these levels. Within a Delphi survey, 112 participants commented on the clarity and usefulness of the CFCS. Interrater reliability was completed by 61 professionals and 68 parents/relatives who classified 69 children with CP aged 2 to 18 years. Test–retest reliability was completed by 48 professionals who allowed at least 2 weeks between classifications. The participants who assessed the CFCS were all relevant stakeholders: adults with CP, parents of children with CP, educators, occupational therapists, physical therapists, physicians, and speech–language pathologists. Results The interrater reliability of the CFCS was 0.66 between two professionals and 0.49 between a parent and a professional. Professional interrater reliability improved to 0.77 for classification of children older than 4 years. The test–retest reliability was 0.82. Interpretation The CFCS demonstrates content validity and shows very good test–retest reliability, good professional interrater reliability, and moderate parent–professional interrater reliability. Combining the CFCS with the Gross Motor Function Classification System and the Manual Ability Classification System contributes to a functional performance view of daily life for individuals with CP, in accordance with the World Health Organization’s International Classification of Functioning, Disability and Health. PMID:21707596

  20. Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes

    PubMed Central

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    Purpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter. PMID:25302580

  1. Psychometric Properties of Translation of the Child Perception Questionnaire (CPQ11-14) in Telugu Speaking Indian Children.

    PubMed

    Kumar, Santhosh; Kroon, Jeroen; Lalloo, Ratilal; Johnson, Newell W

    2016-01-01

    Oral health related quality of life research among children in India is still nascent and no measures have been validated to date. Although CPQ11-14 has been previously used in studies from the Indian sub-continent, the instrument has never been tested for cross-cultural adaptability. This study aimed to assess the validity and reliability of CPQ11-14 in Telugu speaking Indian school children. Primary school children of Medak district, Telangana State, India, were recruited by a multi-stage probability sampling method. The translated questionnaire was initially pilot tested on a small subset of children (n = 40). Children with informed consent from parents (N = 1342) were then provided with questionnaires containing the Telugu translation of CPQ11-14, followed by a clinical examination conducted by a single examiner, using Basic WHO survey methods for dental caries, malocclusion, and Dean's Fluorosis index. Children (n = 161) in randomly chosen schools were re-administered the same questionnaire after a two week interval to test reliability of CPQ11-14 on repeated administrations. Internal consistency and test-retest reliability as determined by Cronbach's alpha and Intra-class correlation coefficient for overall CPQ11-14 scale were 0.925 and 0.923, respectively. CPQ11-14 discriminated between the categories of fluorosis and malocclusion while its discriminant validity with respect to dental caries was limited. CPQ11-14 also demonstrated good construct validity with both overall CPQ11-14 and its subscales having significant positive correlation with global ratings of oral health and overall wellbeing, even after adjusting for confounding variables. CPQ11-14 had a correlation of 0.405 with self-evaluated oral health and 0.407 with self-evaluated impact of oral health on overall wellbeing. In conclusion, Telugu translation of CPQ11-14 demonstrated good internal consistency and excellent reliability on repeated administrations after two weeks. It also exhibited good discriminant and construct validity.

  2. Assessment of reliability, validity, responsiveness and minimally important change of the German Hip dysfunction and osteoarthritis outcome score (HOOS) in patients with osteoarthritis of the hip.

    PubMed

    Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar

    2017-12-01

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.

  3. The development and evaluation of a novel repurposing of a peripheral gaming device for the acquisition of forces applied to a hydraulic treatment plinth.

    PubMed

    Cooper, Darren; Bevins, Joe; Corbett, Mark

    2018-01-13

    This technical note details the stages taken to create an instrumented hydraulic treatment plinth for the measurement of applied forces in the vertical axis. The modification used a widely available low-cost peripheral gaming device and required only basic construction and computer skills. The instrumented treatment plinth was validated against a laboratory grade force platform across a range of applied masses from 0.5-15 kg, mock Gr I-IV vertebral mobilisations and a dynamic response test. Intraclass correlation coefficients demonstrated poor reliability (0.46) for low masses of 0.5 kg improving to excellent for larger masses up to15 kg respectively; excellent to good reliability (0.97-0.86) for the mock mobilisations and moderate reliability (0.51) for the dynamic response test. The study demonstrates how a cheap peripheral gaming device can be repurposed so that forces applied to a hydraulic treatment plinth can be collected reliably when applied in a clinically reasoned manner. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Test-retest reliability and comparability of paper and computer questionnaires for the Finnish version of the Tampa Scale of Kinesiophobia.

    PubMed

    Koho, P; Aho, S; Kautiainen, H; Pohjolainen, T; Hurri, H

    2014-12-01

    To estimate the internal consistency, test-retest reliability and comparability of paper and computer versions of the Finnish version of the Tampa Scale of Kinesiophobia (TSK-FIN) among patients with chronic pain. In addition, patients' personal experiences of completing both versions of the TSK-FIN and preferences between these two methods of data collection were studied. Test-retest reliability study. Paper and computer versions of the TSK-FIN were completed twice on two consecutive days. The sample comprised 94 consecutive patients with chronic musculoskeletal pain participating in a pain management or individual rehabilitation programme. The group rehabilitation design consisted of physical and functional exercises, evaluation of the social situation, psychological assessment of pain-related stress factors, and personal pain management training in order to regain overall function and mitigate the inconvenience of pain and fear-avoidance behaviour. The mean TSK-FIN score was 37.1 [standard deviation (SD) 8.1] for the computer version and 35.3 (SD 7.9) for the paper version. The mean difference between the two versions was 1.9 (95% confidence interval 0.8 to 2.9). Test-retest reliability was 0.89 for the paper version and 0.88 for the computer version. Internal consistency was considered to be good for both versions. The intraclass correlation coefficient for comparability was 0.77 (95% confidence interval 0.66 to 0.85), indicating substantial reliability between the two methods. Both versions of the TSK-FIN demonstrated substantial intertest reliability, good test-retest reliability, good internal consistency and acceptable limits of agreement, suggesting their suitability for clinical use. However, subjects tended to score higher when using the computer version. As such, in an ideal situation, data should be collected in a similar manner throughout the course of rehabilitation or clinical research. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  5. Reliability of two social cognition tests: The combined stories test and the social knowledge test.

    PubMed

    Thibaudeau, Élisabeth; Cellard, Caroline; Legendre, Maxime; Villeneuve, Karèle; Achim, Amélie M

    2018-04-01

    Deficits in social cognition are common in psychiatric disorders. Validated social cognition measures with good psychometric properties are necessary to assess and target social cognitive deficits. Two recent social cognition tests, the Combined Stories Test (COST) and the Social Knowledge Test (SKT), respectively assess theory of mind and social knowledge. Previous studies have shown good psychometric properties for these tests, but the test-retest reliability has never been documented. The aim of this study was to evaluate the test-retest reliability and the inter-rater reliability of the COST and the SKT. The COST and the SKT were administered twice to a group of forty-two healthy adults, with a delay of approximately four weeks between the assessments. Excellent test-retest reliability was observed for the COST, and a good test-retest reliability was observed for the SKT. There was no evidence of practice effect. Furthermore, an excellent inter-rater reliability was observed for both tests. This study shows a good reliability of the COST and the SKT that adds to the good validity previously reported for these two tests. These good psychometrics properties thus support that the COST and the SKT are adequate measures for the assessment of social cognition. Copyright © 2018. Published by Elsevier B.V.

  6. Development and Validation of the Primary Care Team Dynamics Survey

    PubMed Central

    Song, Hummy; Chien, Alyna T; Fisher, Josephine; Martin, Julia; Peters, Antoinette S; Hacker, Karen; Rosenthal, Meredith B; Singer, Sara J

    2015-01-01

    Objective To develop and validate a survey instrument designed to measure team dynamics in primary care. Data Sources/Study Setting We studied 1,080 physician and nonphysician health care professionals working at 18 primary care practices participating in a learning collaborative aimed at improving team-based care. Study Design We developed a conceptual model and administered a cross-sectional survey addressing team dynamics, and we assessed reliability and discriminant validity of survey factors and the overall survey's goodness-of-fit using structural equation modeling. Data Collection We administered the survey between September 2012 and March 2013. Principal Findings Overall response rate was 68 percent (732 respondents). Results support a seven-factor model of team dynamics, suggesting that conditions for team effectiveness, shared understanding, and three supportive processes are associated with acting and feeling like a team and, in turn, perceived team effectiveness. This model demonstrated adequate fit (goodness-of-fit index: 0.91), scale reliability (Cronbach's alphas: 0.71–0.91), and discriminant validity (average factor correlations: 0.49). Conclusions It is possible to measure primary care team dynamics reliably using a 29-item survey. This survey may be used in ambulatory settings to study teamwork and explore the effect of efforts to improve team-based care. Future studies should demonstrate the importance of team dynamics for markers of team effectiveness (e.g., work satisfaction, care quality, clinical outcomes). PMID:25423886

  7. Development and validation of the primary care team dynamics survey.

    PubMed

    Song, Hummy; Chien, Alyna T; Fisher, Josephine; Martin, Julia; Peters, Antoinette S; Hacker, Karen; Rosenthal, Meredith B; Singer, Sara J

    2015-06-01

    To develop and validate a survey instrument designed to measure team dynamics in primary care. We studied 1,080 physician and nonphysician health care professionals working at 18 primary care practices participating in a learning collaborative aimed at improving team-based care. We developed a conceptual model and administered a cross-sectional survey addressing team dynamics, and we assessed reliability and discriminant validity of survey factors and the overall survey's goodness-of-fit using structural equation modeling. We administered the survey between September 2012 and March 2013. Overall response rate was 68 percent (732 respondents). Results support a seven-factor model of team dynamics, suggesting that conditions for team effectiveness, shared understanding, and three supportive processes are associated with acting and feeling like a team and, in turn, perceived team effectiveness. This model demonstrated adequate fit (goodness-of-fit index: 0.91), scale reliability (Cronbach's alphas: 0.71-0.91), and discriminant validity (average factor correlations: 0.49). It is possible to measure primary care team dynamics reliably using a 29-item survey. This survey may be used in ambulatory settings to study teamwork and explore the effect of efforts to improve team-based care. Future studies should demonstrate the importance of team dynamics for markers of team effectiveness (e.g., work satisfaction, care quality, clinical outcomes). © Health Research and Educational Trust.

  8. The Work-Health-Check (WHC): a brief new tool for assessing psychosocial stress in the workplace.

    PubMed

    Gadinger, M C; Schilling, O; Litaker, D; Fischer, J E

    2012-01-01

    Brief, psychometrically robust questionnaires assessing work-related psychosocial stressors are lacking. The purpose of the study is to evaluate the psychometric properties of a brief new questionnaire for assessing sources of work-related psychosocial stress. Managers, blue- and white-collar workers (n= 628 at measurement point one, n=459 at measurement point two), sampled from an online panel of a German marketing research institute. We either developed or identified appropriate items from existing questionnaires for ten scales, which are conceptually based in work stress models and reflected either work-related demands or resources. Factorial structure was evaluated by confirmatory factor analyses (CFA). Scale reliability was assessed by Cronbach's Alpha, and test-retest; correlations with work-related efforts demonstrated convergent and discriminant validity for the demand and resource scales, respectively. Scale correlations with health indicators tested criterion validity. All scales had satisfactory reliability (Cronbach's Alpha: 0.74-0.93, retest reliabilities: 0.66-0.81). CFA supported the anticipated factorial structure. Significant correlations between job-related efforts and demand scales (mean r=0.44) and non-significant correlations with the resource scales (mean r=0.07) suggested good convergent and discriminant validity, respectively. Scale correlations with health indicators demonstrated good criterion validity. The WHC appears to be a brief, psychometrically robust instrument for assessing work-related psychosocial stressors.

  9. Expressed emotion in children: associations with sibling relationships.

    PubMed

    Yelland, I; Daley, D

    2009-07-01

    To investigate the reliability and validity of the expressed emotion (EE) measure, the Pre-school Five Minute Speech Sample (PFMSS), in child-to-child sibling relationships. A total of 106 boys aged 7-11 were recruited from 12 mainstream primary schools in North Wales. The children completed the PFMSS regarding their sibling and two self-report measures of sibling relationship: the Sibling Relationship Questionnaire (SRQ) and a Child Visual Analogue Scale (CVAS). The parents of 60 participants completed the Strengths and Difficulties Questionnaire regarding the behavioural problems of the participating child and his younger sibling. The PFMSS demonstrated good inter-rater and code-recode reliability. The significant associations between EE dimensions such as relationship, positive comments and critical comments with various components of the SRQ and CVAS provided support for the concurrent validity of the PFMSS. Significantly higher levels of Conflict and Rivalry and significantly lower levels of Warmth/Closeness on the SRQ were reported by children with high EE, demonstrating good discriminant validity for the PFMSS. There was no significant association between the child's EE profile and the behavioural difficulties of both siblings as reported by parents. The study found that the PFMSS is a valid and reliable measure of child EE. Future research is needed to clarify the concurrent validity of the warmth and initial statement components of the measure as well as the association between EE dimensions and behaviour.

  10. Ecologically relevant outcome measure for post-inpatient rehabilitation.

    PubMed

    Marquez de la Plata, Carlos; Qualls, Devin; Plenger, Patrick; Malec, James F; Hayden, Mary Ellen

    2017-01-01

    Transfer of skills learned within the clinic environment to patients' home or community is important in post-inpatient brain injury rehabilitation (PBIR). Outcome measures used in PBIR assess level of independence during functional tasks; however, available functional instruments do not quantitate the environment in which the behaviors occur. To examine the reliability and validity of an instrument used to assess patients' functional abilities while quantifying the amount of structure and distractions in the environment. 2501 patients who sustained a traumatic brain injury (TBI) or cerebrovascular accident (CVA) and participated in a multidisciplinary PBIR program between 2006 and 2014 were identified retrospectively for this study. The PERPOS and MPAI-4 were used to assess functional abilities at admission and at discharge. Construct validity was assessed using a bivariate Spearman rho analysis A subsample of 56 consecutive admissions during 2014 were examined to determine inter-rater reliability. Intra-class correlation coefficient (ICC) and Kappa coefficients assessed inter-rater agreement of the total PERPOS and PERPOS subscales respectively. The PERPOS and MPAI-4 demonstrated a strong negative association among both TBI and CVA patients. Kappa scores for the three PERPOS scales each demonstrated good to excellent inter-rater agreement. The ICC for overall PERPOS scores fell in the good agreement range. The PERPOS can be used reliably in PBIR to quantify patients' functional abilities within the context of environmental demands.

  11. Test-retest reliability of fMRI-based graph theoretical properties during working memory, emotion processing, and resting state.

    PubMed

    Cao, Hengyi; Plichta, Michael M; Schäfer, Axel; Haddad, Leila; Grimm, Oliver; Schneider, Michael; Esslinger, Christine; Kirsch, Peter; Meyer-Lindenberg, Andreas; Tost, Heike

    2014-01-01

    The investigation of the brain connectome with functional magnetic resonance imaging (fMRI) and graph theory analyses has recently gained much popularity, but little is known about the robustness of these properties, in particular those derived from active fMRI tasks. Here, we studied the test-retest reliability of brain graphs calculated from 26 healthy participants with three established fMRI experiments (n-back working memory, emotional face-matching, resting state) and two parcellation schemes for node definition (AAL atlas, functional atlas proposed by Power et al.). We compared the intra-class correlation coefficients (ICCs) of five different data processing strategies and demonstrated a superior reliability of task-regression methods with condition-specific regressors. The between-task comparison revealed significantly higher ICCs for resting state relative to the active tasks, and a superiority of the n-back task relative to the face-matching task for global and local network properties. While the mean ICCs were typically lower for the active tasks, overall fair to good reliabilities were detected for global and local connectivity properties, and for the n-back task with both atlases, smallworldness. For all three tasks and atlases, low mean ICCs were seen for the local network properties. However, node-specific good reliabilities were detected for node degree in regions known to be critical for the challenged functions (resting-state: default-mode network nodes, n-back: fronto-parietal nodes, face-matching: limbic nodes). Between-atlas comparison demonstrated significantly higher reliabilities for the functional parcellations for global and local network properties. Our findings can inform the choice of processing strategies, brain atlases and outcome properties for fMRI studies using active tasks, graph theory methods, and within-subject designs, in particular future pharmaco-fMRI studies. © 2013 Elsevier Inc. All rights reserved.

  12. A systematic review of the factor structure and reliability of the Spence Children's Anxiety Scale.

    PubMed

    Orgilés, Mireia; Fernández-Martínez, Iván; Guillén-Riquelme, Alejandro; Espada, José P; Essau, Cecilia A

    2016-01-15

    The Spence Children's Anxiety Scale (SCAS) is a widely used instrument for assessing symptoms of anxiety disorders among children and adolescents. Previous studies have demonstrated its good reliability for children and adolescents from different backgrounds. However, remarkable variability in the reliability of the SCAS across studies and inconsistent results regarding its factor structure has been found. The present study aims to examine the SCAS factor structure by means of a systematic review with narrative synthesis, the mean reliability of the SCAS by means of a meta-analysis, and the influence of the moderators on the SCAS reliability. Databases employed to collect the studies included Scholar Google, PsycARTICLES, PsycINFO, Web of Science, and Scopus since 1997. Twenty-nine and 32 studies, which examined the factor structure and the internal consistency of the SCAS, respectively, were included. The SCAS was found to have strong internal consistency, influenced by different moderators. The systematic review demonstrated that the original six-factor model was supported by most studies. Factorial invariance studies (across age, gender, country) and test-retest reliability of the SCAS were not examined in this study. It is concluded that the SCAS is a reliable instrument for cross-cultural use, and it is suggested that the original six-factor model is appropriate for cross-cultural application. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Reliability of the Structured Clinical Interview for DSM-5 Sleep Disorders Module.

    PubMed

    Taylor, Daniel J; Wilkerson, Allison K; Pruiksma, Kristi E; Williams, Jacob M; Ruggero, Camilo J; Hale, Willie; Mintz, Jim; Organek, Katherine Marczyk; Nicholson, Karin L; Litz, Brett T; Young-McCaughan, Stacey; Dondanville, Katherine A; Borah, Elisa V; Brundige, Antoinette; Peterson, Alan L

    2018-03-15

    To develop and demonstrate interrater reliability for a Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) Sleep Disorders (SCISD). The SCISD was designed to be a brief, reliable, and valid interview assessment of adult sleep disorders as defined by the DSM-5. A sample of 106 postdeployment active-duty military members seeking cognitive behavioral therapy for insomnia in a randomized clinical trial were assessed with the SCISD prior to treatment to determine eligibility. Audio recordings of these interviews were double-scored for interrater reliability. The interview is 8 pages long, includes 20 to 51 questions, and takes 10 to 20 minutes to administer. Of the nine major disorders included in the SCISD, six had prevalence rates high enough (ie, n ≥ 5) to include in analyses. Cohen kappa coefficient (κ) was used to assess interrater reliability for insomnia, hypersomnolence, obstructive sleep apnea hypopnea (OSAH), circadian rhythm sleep-wake, nightmare, and restless legs syndrome disorders. There was excellent interrater reliability for insomnia (1.0) and restless legs syndrome (0.83); very good reliability for nightmare disorder (0.78) and OSAH (0.73); and good reliability for hypersomnolence (0.50) and circadian rhythm sleep-wake disorders (0.50). The SCISD is a brief, structured clinical interview that is easy for clinicians to learn and use. The SCISD showed moderate to excellent interrater reliability for six of the major sleep disorders in the DSM-5 among active duty military seeking cognitive behavioral therapy for insomnia in a randomized clinical trial. Replication and extension studies are needed. Registry: ClinicalTrials.gov; Title: Comparing Internet and In-Person Brief Cognitive Behavioral Therapy of Insomnia; Identifier: NCT01549899; URL: https://clinicaltrials.gov/ct2/show/NCT01549899. © 2018 American Academy of Sleep Medicine.

  14. The Childhood Asperger Syndrome Test (CAST): Test-Retest Reliability in a High Scoring Sample

    ERIC Educational Resources Information Center

    Allison, Carrie; Williams, Jo; Scott, Fiona; Stott, Carol; Bolton, Patrick; Baron-Cohen, Simon; Brayne, Carol

    2007-01-01

    The Childhood Asperger Syndrome Test (CAST) is a 37-item parental self-completion questionnaire designed to screen for high-functioning autism spectrum conditions in epidemiological research. The CAST has previously demonstrated good accuracy for use as a screening test, with high sensitivity in studies with primary school aged children in…

  15. Psychometric Properties of the French Version of the Adult Dispositional Hope Scale

    ERIC Educational Resources Information Center

    Gana, Kamel; Daigre, Stephanie; Ledrich, Julie

    2013-01-01

    In this article, we present a French adaptation and validation of the Adult Dispositional Hope Scale (ADHS). The sample was composed of 310 French adults. We found that the ADHS scores demonstrated good reliability as well as adequate temporal stability. Confirmatory factor analyses (CFA) supported a bifactorial structure of the scale. The two…

  16. Serendipitous data following a severe windstorm in an old-growth pine stand

    Treesearch

    D.C. Bragg; J.D. Riddle

    2014-01-01

    Reliable dimensional data for old-growth pine-dominated forests in the Gulf Coastal Plain of Arkansas are hard to find, but sometimes unfortunate circumstances provide good opportunities to acquire this information. On July 11, 2013, a severe thunderstorm with high winds struck the Levi Wilcoxon Demonstration Forest (LWDF) near Hamburg, Arkansas. This storm uprooted or...

  17. The Validation of the Interpersonal Reactivity Index for Chinese Teachers from Primary and Middle Schools

    ERIC Educational Resources Information Center

    Huang, Xiaozhong; Li, Weijian; Sun, Binghai; Chen, Haide; Davis, Mark H.

    2012-01-01

    Psychometric properties of the Chinese version of Interpersonal Reactivity Index (C-IRI) were examined in a sample of 930 teachers in China. The subscales of the C-IRI demonstrated acceptable to good internal consistency and test-retest reliability. Exploratory and confirmatory factor analyses revealed a stable four-factor structure across three…

  18. Reliability and Validity of the Self Efficacy Expectations and Outcome Expectations After ICD Implantation Scales

    PubMed Central

    Dougherty, Cynthia M.; Johnston, Sandra K.; Thompson, Elaine Adams

    2009-01-01

    The purpose of this study was to assess the reliability and validity characteristics of two new scales that measure self-efficacy expectations (SE-ICD) and outcome expectations (OE-ICD) in survivors (n=168) of sudden cardiac arrest (SCA), all of whom received an implantable cardioverter defibrillator (ICD). Cronbach's alpha reliability demonstrated good internal consistency (SE-ICD α = 0.93 and OE-ICD α = 0.81). Correlations with other self-efficacy instruments (general self-efficacy and social self-efficacy) were consistently high. The instruments were responsive to change across time with effect sizes of 0.46 for SE-ICD, and 0.26 for OE-ICD. These reliable, valid, and responsive instruments for measurement of self-efficacy expectations and outcome expectations after an ICD can be used in research and clinical settings. PMID:17693214

  19. The hospital anxiety and depression scale--dimensionality, reliability and construct validity among cognitively intact nursing home patients.

    PubMed

    Haugan, Gørill; Drageset, Jorunn

    2014-08-01

    Depression and anxiety are particularly common among individuals living in long-term care facilities. Therefore, access to a valid and reliable measure of anxiety and depression among nursing home patients is highly warranted. To investigate the dimensionality, reliability and construct validity of the Hospital Anxiety and Depression scale (HADS) in a cognitively intact nursing home population. Cross-sectional data were collected from two samples; 429 cognitively intact nursing home patients participated, representing 74 different Norwegian nursing homes. Confirmative factor analyses and correlations with selected constructs were used. The two-factor model provided a good fit in Sample1, revealing a poorer fit in Sample2. Good-acceptable measurement reliability was demonstrated, and construct validity was supported. Using listwise deletion the sample sizes were 227 and 187, for Sample1 and Sample2, respectively. Greater sample sizes would have strengthen the statistical power in the tests. The researchers visited the participants to help fill in the questionnaires; this might have introduced some bias into the respondents׳ reporting. The 14 HADS items were part of greater questionnaires. Thus, frail, older NH patients might have tired during the interview causing a possible bias. Low reliability for depression was disclosed, mainly resulting from three items appearing to be inappropriate indicators for depression in this population. Further research is needed exploring which items might perform as more reliably indicators for depression among nursing home patients. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Reliability of conditioned pain modulation: a systematic review

    PubMed Central

    Kennedy, Donna L.; Kemp, Harriet I.; Ridout, Deborah; Yarnitsky, David; Rice, Andrew S.C.

    2016-01-01

    Abstract A systematic literature review was undertaken to determine if conditioned pain modulation (CPM) is reliable. Longitudinal, English language observational studies of the repeatability of a CPM test paradigm in adult humans were included. Two independent reviewers assessed the risk of bias in 6 domains; study participation; study attrition; prognostic factor measurement; outcome measurement; confounding and analysis using the Quality in Prognosis Studies (QUIPS) critical assessment tool. Intraclass correlation coefficients (ICCs) less than 0.4 were considered to be poor; 0.4 and 0.59 to be fair; 0.6 and 0.75 good and greater than 0.75 excellent. Ten studies were included in the final review. Meta-analysis was not appropriate because of differences between studies. The intersession reliability of the CPM effect was investigated in 8 studies and reported as good (ICC = 0.6-0.75) in 3 studies and excellent (ICC > 0.75) in subgroups in 2 of those 3. The assessment of risk of bias demonstrated that reporting is not comprehensive for the description of sample demographics, recruitment strategy, and study attrition. The absence of blinding, a lack of control for confounding factors, and lack of standardisation in statistical analysis are common. Conditioned pain modulation is a reliable measure; however, the degree of reliability is heavily dependent on stimulation parameters and study methodology and this warrants consideration for investigators. The validation of CPM as a robust prognostic factor in experimental and clinical pain studies may be facilitated by improvements in the reporting of CPM reliability studies. PMID:27559835

  1. Consistency of clinical biomechanical measures between three different institutions: implications for multi-center biomechanical and epidemiological research.

    PubMed

    Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E

    2014-05-01

    Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.

  2. Inter-operator and inter-device agreement and reliability of the SEM Scanner.

    PubMed

    Clendenin, Marta; Jaradeh, Kindah; Shamirian, Anasheh; Rhodes, Shannon L

    2015-02-01

    The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Inter-operator and inter-device agreement and reliability were estimated. Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. Copyright © 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.. All rights reserved.

  3. Measuring competence in endoscopic sinus surgery.

    PubMed

    Syme-Grant, J; White, P S; McAleer, J P G

    2008-02-01

    Competence based education is currently being introduced into higher surgical training in the UK. Valid and reliable performance assessment tools are essential to ensure competencies are achieved. No such tools have yet been reported in the UK literature. We sought to develop and pilot test an Endoscopic Sinus Surgery Competence Assessment Tool (ESSCAT). The ESSCAT was designed for in-theatre assessment of higher surgical trainees in the UK. The ESSCAT rating matrix was developed through task analysis of ESS procedures. All otolaryngology consultants and specialist registrars in Scotland were given the opportunity to contribute to its refinement. Two cycles of in-theatre testing were used to ensure utility and gather quantitative data on validity and reliability. Videos of trainees performing surgery were used in establishing inter-rater reliability. National consultation, the consensus derived minimum standard of performance, Cronbach's alpha = 0.89 and demonstration of trainee learning (p = 0.027) during the in vivo application of the ESSCAT suggest a high level of validity. Inter-rater reliability was moderate for competence decisions (Cohen's Kappa = 0.5) and good for total scores (Intra-Class Correlation Co-efficient = 0.63). Intra-rater reliability was good for both competence decisions (Kappa = 0.67) and total scores (Kendall's Tau-b = 0.73). The ESSCAT generates a valid and reliable assessment of trainees' in-theatre performance of endoscopic sinus surgery. In conjunction with ongoing evaluation of the instrument we recommend the use of the ESSCAT in higher specialist training in otolaryngology in the UK.

  4. Validity and Reliability of the 8-Item Work Limitations Questionnaire.

    PubMed

    Walker, Timothy J; Tullar, Jessica M; Diamond, Pamela M; Kohl, Harold W; Amick, Benjamin C

    2017-12-01

    Purpose To evaluate factorial validity, scale reliability, test-retest reliability, convergent validity, and discriminant validity of the 8-item Work Limitations Questionnaire (WLQ) among employees from a public university system. Methods A secondary analysis using de-identified data from employees who completed an annual Health Assessment between the years 2009-2015 tested research aims. Confirmatory factor analysis (CFA) (n = 10,165) tested the latent structure of the 8-item WLQ. Scale reliability was determined using a CFA-based approach while test-retest reliability was determined using the intraclass correlation coefficient. Convergent/discriminant validity was tested by evaluating relations between the 8-item WLQ with health/performance variables for convergent validity (health-related work performance, number of chronic conditions, and general health) and demographic variables for discriminant validity (gender and institution type). Results A 1-factor model with three correlated residuals demonstrated excellent model fit (CFI = 0.99, TLI = 0.99, RMSEA = 0.03, and SRMR = 0.01). The scale reliability was acceptable (0.69, 95% CI 0.68-0.70) and the test-retest reliability was very good (ICC = 0.78). Low-to-moderate associations were observed between the 8-item WLQ and the health/performance variables while weak associations were observed between the demographic variables. Conclusions The 8-item WLQ demonstrated sufficient reliability and validity among employees from a public university system. Results suggest the 8-item WLQ is a usable alternative for studies when the more comprehensive 25-item WLQ is not available.

  5. Precarious employment in Chile: psychometric properties of the Chilean version of Employment Precariousness Scale in private sector workers.

    PubMed

    Vives-Vergara, Alejandra; González-López, Francisca; Solar, Orielle; Bernales-Baksai, Pamela; González, María José; Benach, Joan

    2017-04-20

    The purpose of this study is to perform a psychometric analysis (acceptability, reliability and factor structure) of the Chilean version of the new Employment Precariousness Scale (EPRES). The data is drawn from a sample of 4,248 private salaried workers with a formal contract from the first Chilean Employment Conditions, Work, Health and Quality of Life (ENETS) survey, applied to a nationally representative sample of the Chilean workforce in 2010. Item and scale-level statistics were performed to assess scaling properties, acceptability and reliability. The six-dimensional factor structure was examined with confirmatory factor analysis. The scale exhibited high acceptability (roughly 80%) and reliability (Cronbach's alpha 0.83) and the factor structure was confirmed. One subscale (rights) demonstrated poorer metric properties without compromising the overall scale. The Chilean version of the Employment Precariousness Scale (EPRES-Ch) demonstrated good metric properties, pointing to its suitability for use in epidemiologic and public health research.

  6. Satisfactory reliability among nursing students using the instrument PVC ASSESS to evaluate management of peripheral venous catheters.

    PubMed

    Ahlqvist, Margary; Berglund, Britta; Nordström, Gun; Klang, Birgitta; Johansson, Eva

    2014-01-01

    Nursing students should be given opportunities to participate in clinical audits during their education. However, audit tools are seldom tested for reliability among nursing students. The aim of this study was to present reliability among nursing students using the instrument PVC assess to assess management of peripheral venous catheters (PVCs) and PVC-related signs of thrombophlebitis. PVC assess was used to assess 67 inserted PVCs in 60 patients at ten wards at a university hospital. One group of nursing students (n=4) assessed PVCs at the bedside (inter-rater reliability) and photographs of these PVCs were taken. Another group of students (n=3) assessed the PVCs in the photographs after 4 weeks (test-retest reliability). To determine reliability, proportion of agreement [P(A)] and Cohen's kappa coefficient (κ) were calculated. For bedside assessment of PVCs, P(A) ranged from good to excellent (0.80-1.0) in 55% of the 26 PVC assess items that were tested. P(A) was poor (<0.70) for two items: "adherence of inner dressing to the skin" and "PVC location." In 81% of the items, κ was between moderate and almost perfect: moderate (n=5), substantial (n=3), almost perfect (n=5). For edema at insertion site and two items on PVC dressing, κ was fair (0.21-0.40). Regarding test-retest reliability, P(A) varied between good and excellent (0.81-1) in 85%-95% of the items, and the κ ranged between moderate and almost perfect (0.41-1) in 90%-95%. PVC assess demonstrated satisfactory reliability among nursing students. However, students need training in how to use the instrument before assessing PVCs.

  7. The reliability of a maximal isometric hip strength and simultaneous surface EMG screening protocol in elite, junior rugby league athletes.

    PubMed

    Charlton, Paula C; Mentiplay, Benjamin F; Grimaldi, Alison; Pua, Yong-Hao; Clark, Ross A

    2017-02-01

    Firstly to describe the reliability of assessing maximal isometric strength of the hip abductor and adductor musculature using a hand held dynamometry (HHD) protocol with simultaneous wireless surface electromyographic (sEMG) evaluation of the gluteus medius (GM) and adductor longus (AL). Secondly, to describe the correlation between isometric strength recorded with the HHD protocol and a laboratory standard isokinetic device. Reliability and correlational study. A sample of 24 elite, male, junior, rugby league athletes, age 16-20 years participated in repeated HHD and isometric Kin-Com (KC) strength testing with simultaneous sEMG assessment, on average (range) 6 (5-7) days apart by a single assessor. Strength tests included; unilateral hip abduction (ABD) and adduction (ADD) and bilateral ADD assessed with squeeze (SQ) tests in 0 and 45° of hip flexion. HHD demonstrated good to excellent inter-session reliability for all outcome measures (ICC (2,1) =0.76-0.91) and good to excellent association with the laboratory reference KC (ICC (2,1) =0.80-0.88). Whilst intra-session, inter-trial reliability of EMG activation and co-activation outcome measures ranged from moderate to excellent (ICC (2,1) =0.70-0.94), inter-session reliability was poor (all ICC (2,1) <0.50). Isometric strength testing of the hip ABD and ADD musculature using HHD may be measured reliably in elite, junior rugby league athletes. Due to the poor inter-session reliability of sEMG measures, it is not recommended for athlete screening purposes if using the techniques implemented in this study. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  8. Reliability and validity of the PedsQL™ Multidimensional Fatigue Scale in Japan.

    PubMed

    Kobayashi, Kyoko; Okano, Yoshiyuki; Hohashi, Naohiro

    2011-09-01

    To examine the reliability and validity of the Japanese-language version of the PedsQL™ Multidimensional Fatigue Scale and to investigate the agreement between child self-reported fatigue and parent proxy-reported fatigue. The Japanese-language version of the PedsQL™ Multidimensional Fatigue Scale was administered to 652 preschoolers and schoolchildren aged 5-12 and their parents, and to 91 parents of preschool children aged 1-4. Internal consistency reliability was 0.62-0.87 for children and 0.81-0.93 for parents. Known-group validity was examined between a group of healthy samples (n = 530) and chronic condition sample (n = 102); the chronically ill group reported a significantly higher perceived fatigue problem. Correlations between child self- and parent proxy reports ranged from poor to fair. In subgroups identified by cluster analysis based on child self-reported scores, the greatest agreement between child and parent reports was seen in the good HRQOL group, while the least occurred in the poor HRQOL group. The parents overestimated their child's fatigue more when the child's HRQOL was low. The Japanese-language version of the PedsQL™ Multidimensional Fatigue Scale demonstrated good reliability and validity and could be useful in evaluating Japanese children in school and health care settings.

  9. Reliability, validity and responsiveness of the German self-reported foot and ankle score (SEFAS) in patients with foot or ankle surgery.

    PubMed

    Arbab, Dariusch; Kuhlmann, Katharina; Schnurr, Christoph; Bouillon, Bertil; Lüring, Christian; König, Dietmar

    2017-10-10

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures and are increasingly used in clinical trials to assess outcomes of health care. The intention of this study was to develop and culturally adapt a German version of the Self-reported Foot and Ankle Score (SEFAS) and to evaluate reliability, validity and responsiveness. According to Cross Cultural Adaptation of Self-Reported Measure guidelines forward and backward translation has been performed. The German SEFAS was investigated in 177 consecutive patients. 177 Patients completed the German SEFAS, Foot and Ankle Outcome Score (FAOS), Short-Form 36 and numeric scales for pain and disability (NRS) before and 118 patients 6 months after foot or ankle surgery. Test-Retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German SEFAS demonstrated excellent test-retest reliability with ICC values of 0.97. Cronbach's alpha (α) value of 0.89 demonstrated strong internal consistency. No floor or ceiling effects were observed for the German version of the SEFAS. As hypothesized SEFAS correlated strongly with FAOS and SF-36 domains. It showed moderate (ES/SRM > 0.5) responsiveness between preoperative assessment and postoperative follow-up. The German version of the SEFAS demonstrated good psychometric properties. It proofed to be a valid and reliable instrument for use in foot and ankle patients. DRKS00007585.

  10. Reliability and validity of Arabic translation of Medication Adherence Report Scale (MARS) and Beliefs about Medication Questionnaire (BMQ)–specific for use in children and their parents

    PubMed Central

    Alsous, Mervat; Alhalaiqa, Fadwa; Abu Farha, Rana; Abdel Jalil, Mariam; McElnay, James; Horne, Robert

    2017-01-01

    Objectives to evaluate the reliability and discriminant validity of Arabic translation of the Medication Adherence Report Scale (MARS) and the Beliefs about Medication Questionnaire-specific (BMQ-specific). Methods Having developed Arabic translations of the study instruments, a cross-sectional study was carried out between March and October 2015 in two multidisciplinary governmental hospitals in Jordan. An expert panel monitored the forward and backward translation of the MARS and BMQ. Standard Arabic was used (with no specific dialect inclusion) to allow greater generalisability across Arabic speaking countries. Once the Arabic translations of the questionnaires were developed they were tested for consistency, validity and reliability on a group of children with chronic diseases and their parents. Results A total of 258 parents and 208 children were included in the study. The median age of participated children and parents was 15 years and 42 years respectively. Principle component analysis of all questionnaires indicated that all had good construct validity as they clearly measured one construct. The questionnaires were deemed reliable based on the results of Cronbach alpha coefficient. Furthermore, reliability of the questionnaires was demonstrated by test-retest intraclass correlation coefficients (ICC) which ranged from good to excellent for all scales (ICC>0.706). The Pearson correlation coefficient ranged from 0.546–0.805 for the entire sample which indicated a significant moderate to strong positive correlation between MARS and BMQ items at time 1 and 2. Reported adherence was greater than 59% using MARS-children and MARS-parents scales, and was correlated with beliefs in necessity and independent of the concerns regarding medications. Conclusion The Arabic translations of both BMQ and MARS for use in children and their parents have good internal consistency and proved to be valid and reliable tools that can be used by researchers in clinical practice to measure adherence and beliefs about medications in Arabic speaking patient populations. PMID:28192467

  11. Reliability and validity of Arabic translation of Medication Adherence Report Scale (MARS) and Beliefs about Medication Questionnaire (BMQ)-specific for use in children and their parents.

    PubMed

    Alsous, Mervat; Alhalaiqa, Fadwa; Abu Farha, Rana; Abdel Jalil, Mariam; McElnay, James; Horne, Robert

    2017-01-01

    to evaluate the reliability and discriminant validity of Arabic translation of the Medication Adherence Report Scale (MARS) and the Beliefs about Medication Questionnaire-specific (BMQ-specific). Having developed Arabic translations of the study instruments, a cross-sectional study was carried out between March and October 2015 in two multidisciplinary governmental hospitals in Jordan. An expert panel monitored the forward and backward translation of the MARS and BMQ. Standard Arabic was used (with no specific dialect inclusion) to allow greater generalisability across Arabic speaking countries. Once the Arabic translations of the questionnaires were developed they were tested for consistency, validity and reliability on a group of children with chronic diseases and their parents. A total of 258 parents and 208 children were included in the study. The median age of participated children and parents was 15 years and 42 years respectively. Principle component analysis of all questionnaires indicated that all had good construct validity as they clearly measured one construct. The questionnaires were deemed reliable based on the results of Cronbach alpha coefficient. Furthermore, reliability of the questionnaires was demonstrated by test-retest intraclass correlation coefficients (ICC) which ranged from good to excellent for all scales (ICC>0.706). The Pearson correlation coefficient ranged from 0.546-0.805 for the entire sample which indicated a significant moderate to strong positive correlation between MARS and BMQ items at time 1 and 2. Reported adherence was greater than 59% using MARS-children and MARS-parents scales, and was correlated with beliefs in necessity and independent of the concerns regarding medications. The Arabic translations of both BMQ and MARS for use in children and their parents have good internal consistency and proved to be valid and reliable tools that can be used by researchers in clinical practice to measure adherence and beliefs about medications in Arabic speaking patient populations.

  12. Time to competency, reliability of flexible transnasal laryngoscopy by training level: a pilot study.

    PubMed

    Brook, Christopher D; Platt, Michael P; Russell, Kimberly; Grillone, Gregory A; Aliphas, Avner; Noordzij, J Pieter

    2015-05-01

    To determine the progression of flexible transnasal laryngoscopy reliability and competency in otolaryngology residency training. Prospective case control study. Academic otolaryngology department. Medical students, otolaryngology residents, and otolaryngology attending physicians. Fourteen otolaryngology residents from PGY-1 to PGY-5 and 3 attending otolaryngologists viewed 25 selected and digitally recorded flexible transnasal laryngoscopies. The evaluators were asked to rate 13 items relating to abnormalities in the oropharynx, hypopharynx, larynx, and subglottis. The level of concern and level of comfort with the diagnosis were assessed. Intraclass correlations were calculated for each topic and by level of training to determine reliability within each class and compare competency versus attending interpretations. Intraclass correlation of residents compared to attending physicians demonstrated significant improvements by year for left and right vocal fold immobility, subglottic stenosis, laryngeal mass, left and right vocal cord abnormalities, and level of concern. Additionally, pooled vocal cord mobility and pooled results in categories with good attending reliability demonstrated stepwise improvement as well. For these categories, resident reliability was found to be statistically similar to attending physicians in all categories by PGY-3. There were no trends for base of tongue abnormalities, pharyngeal abnormalities, and pharyngeal and hypopharyngeal masses. Resident competency for flexible transnasal laryngoscopy progresses during residency to reliability with attending otolaryngologists by the PGY-3 year over key facets of the examination. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.

  13. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    PubMed

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and ≤5.3° for the sacral angles. The variability in the linear measurements (distances) was <4 mm. The variance of the measures was 1.7 and 2.6 times greater, respectively, for the angular and linear measures between the inter- and intrameasurer reliability. The image quality positively influenced the intermeasurer reliability especially for the proximal thoracic Cobb angle, T10-L2 lordosis, sacral slope and L5 seating. The accuracy study revealed that on average the difference in the angular measures was < 2° for the Cobb angles, and < 4° for the other angles, except T2-T12 kyphosis (5.3°). The linear measures were all <3.5 mm difference on average. The majority of the measures, which were analyzed in this study demonstrated good to excellent reliability and accuracy. The novel semiautomatic measurement software can be recommended for use for clinical, research or multicenter study purposes.

  14. Validation of the Short Form of the Career Development Inventory with an Iranian High School Sample

    ERIC Educational Resources Information Center

    Sadeghi, Ahmad; Baghban, Iran; Bahrami, Fatemeh; Ahmadi, Ahmad; Creed, Peter

    2011-01-01

    A short 33-item form of the Career Development Inventory was validated on a sample of 310 Iranian high school students. Factor analysis indicated that attitude and cognitive subscale items loaded on their respective factors, and that internal reliability coefficients at all levels were satisfactory to good. Support for validity was demonstrated by…

  15. Construction and Validation of the Career and Educational Decision Self-Efficacy Inventory for Secondary Students (CEDSIS)

    ERIC Educational Resources Information Center

    Ho, Esther Sui Chu; Sum, Kwok Wing

    2018-01-01

    This study aims to construct and validate the Career and Educational Decision Self-Efficacy Inventory for Secondary Students (CEDSIS) by using a sample of 2,631 students in Hong Kong. Principal component analysis yielded a three-factor structure, which demonstrated good model fit in confirmatory factor analysis. High reliability was found for the…

  16. Calibration of the Dutch-Flemish PROMIS Pain Behavior item bank in patients with chronic pain.

    PubMed

    Crins, M H P; Roorda, L D; Smits, N; de Vet, H C W; Westhovens, R; Cella, D; Cook, K F; Revicki, D; van Leeuwen, J; Boers, M; Dekker, J; Terwee, C B

    2016-02-01

    The aims of the current study were to calibrate the item parameters of the Dutch-Flemish PROMIS Pain Behavior item bank using a sample of Dutch patients with chronic pain and to evaluate cross-cultural validity between the Dutch-Flemish and the US PROMIS Pain Behavior item banks. Furthermore, reliability and construct validity of the Dutch-Flemish PROMIS Pain Behavior item bank were evaluated. The 39 items in the bank were completed by 1042 Dutch patients with chronic pain. To evaluate unidimensionality, a one-factor confirmatory factor analysis (CFA) was performed. A graded response model (GRM) was used to calibrate the items. To evaluate cross-cultural validity, Differential item functioning (DIF) for language (Dutch vs. English) was evaluated. Reliability of the item bank was also examined and construct validity was studied using several legacy instruments, e.g. the Roland Morris Disability Questionnaire. CFA supported the unidimensionality of the Dutch-Flemish PROMIS Pain Behavior item bank (CFI = 0.960, TLI = 0.958), the data also fit the GRM, and demonstrated good coverage across the pain behavior construct (threshold parameters range: -3.42 to 3.54). Analysis showed good cross-cultural validity (only six DIF items), reliability (Cronbach's α = 0.95) and construct validity (all correlations ≥0.53). The Dutch-Flemish PROMIS Pain Behavior item bank was found to have good cross-cultural validity, reliability and construct validity. The development of the Dutch-Flemish PROMIS Pain Behavior item bank will serve as the basis for Dutch-Flemish PROMIS short forms and computer adaptive testing (CAT). © 2015 European Pain Federation - EFIC®

  17. NEWS for Africa: adaptation and reliability of a built environment questionnaire for physical activity in seven African countries.

    PubMed

    Oyeyemi, Adewale L; Kasoma, Sandra S; Onywera, Vincent O; Assah, Felix; Adedoyin, Rufus A; Conway, Terry L; Moss, Sarah J; Ocansey, Reginald; Kolbe-Alexander, Tracy L; Akinroye, Kingsley K; Prista, Antonio; Larouche, Richard; Gavand, Kavita A; Cain, Kelli L; Lambert, Estelle V; Aryeetey, Richmond; Bartels, Clare; Tremblay, Mark S; Sallis, James F

    2016-03-08

    Built environment and policy interventions are effective strategies for controlling the growing worldwide deaths from physical inactivity-related non-communicable diseases. To improve built environment research and develop African specific evidence, it is important to first tailor built environment measures to African contexts and assess their psychometric properties across African countries. This study reports on the adaptation and test-retest reliability of the Neighborhood Environment Walkability Scale in seven sub-Saharan African countries (NEWS-Africa). The original NEWS comprising 8 subscales measuring reported physical and social attributes of neighborhood environments was systematically adapted for Africa through extensive input from physical activity and public health researchers, built environment professionals, and residents in seven African countries: Cameroon, Ghana, Kenya, Mozambique, Nigeria, South Africa and Uganda. Cognitive testing of NEWS-Africa was conducted among diverse residents (N = 109, 50 youth [12 - 17 years] and 59 adults [22 - 67 years], 69 % from low socioeconomic status [SES] neighborhoods). NEWS-Africa was translated into local languages and evaluated for 2-week test-retest reliability in adult participants (N = 301; female = 50.2 %; age = 32.3 ± 12.9 years) purposively recruited from neighborhoods varying in walkability (high and low walkable) and SES (high and low income) and from villages in six of seven participating countries. The original 67 NEWS items was expanded to 89 scores (76 individual NEWS items and 13 computed scales). Several modifications were made to individual items, and some new items were added to capture important attributes in the African environment. A new scale on personal safety was created, and the aesthetics scale was enlarged to reflect African specific characteristics. Over 95 % of all NEWS-Africa scores (items plus computed scales) demonstrated evidence of "excellent" (ICCs > .75 %) or "good" (ICCs = 0.60 to 0.74) reliability. Seven (53.8 %) of the 13 computed NEWS scales demonstrated "excellent" agreement and the other six had "good" agreement. No items or scales demonstrated "poor" reliability (ICCs < .40). The systematic adaptation and initial psychometric evaluation of NEWS-Africa indicates the instrument is feasible and reliable for use with adults of diverse demographic characteristics in Africa. The measure is likely to be useful for research, surveillance of built environment conditions for planning purposes, and to evaluate physical activity and policy interventions in Africa.

  18. Development and implementation of the Structured Training Trainer Assessment Report (STTAR) in the English National Training Programme for laparoscopic colorectal surgery.

    PubMed

    Wyles, Susannah M; Miskovic, Danilo; Ni, Zhifang; Darzi, Ara W; Valori, Roland M; Coleman, Mark G; Hanna, George B

    2016-03-01

    There is a lack of educational tools available for surgical teaching critique, particularly for advanced laparoscopic surgery. The aim was to develop and implement a tool that assesses training quality and structures feedback for trainers in the English National Training Programme for laparoscopic colorectal surgery. Semi-structured interviews were performed and analysed, and items were extracted. Through the Delphi process, essential items pertaining to desirable trainer characteristics, training structure and feedback were determined. An assessment tool (Structured Training Trainer Assessment Report-STTAR) was developed and tested for feasibility, acceptability and educational impact. Interview transcripts (29 surgical trainers, 10 trainees, four educationalists) were analysed, and item lists created and distributed for consensus opinion (11 trainers and seven trainees). The STTAR consisted of 64 factors, and its web-based version, the mini-STTAR, included 21 factors that were categorised into four groups (training structure, training behaviour, trainer attributes and role modelling) and structured around a training session timeline (beginning, middle and end). The STTAR (six trainers, 48 different assessments) demonstrated good internal consistency (α = 0.88) and inter-rater reliability (ICC = 0.75). The mini-STTAR demonstrated good inter-item reliability (α = 0.79) and intra-observer reliability on comparison of 85 different trainer/trainee combinations (r = 0.701, p = <0.001). Both were found to be feasible and acceptable. The educational report for trainers was found to be useful (4.4 out of 5). An assessment tool that evaluates training quality was developed and shown to be reliable, acceptable and of educational value. It has been successfully implemented into the English National Training Programme for laparoscopic colorectal surgery.

  19. Student Practice Evaluation Form-Revised Edition online comment bank: development and reliability analysis.

    PubMed

    Rodger, Sylvia; Turpin, Merrill; Copley, Jodie; Coleman, Allison; Chien, Chi-Wen; Caine, Anne-Maree; Brown, Ted

    2014-08-01

    The reliable evaluation of occupational therapy students completing practice education placements along with provision of appropriate feedback is critical for both students and for universities from a quality assurance perspective. This study describes the development of a comment bank for use with an online version of the Student Practice Evaluation Form-Revised Edition (SPEF-R Online) and investigates its reliability. A preliminary bank of 109 individual comments (based on previous students' placement performance) was developed via five stages. These comments reflected all 11 SPEF-R domains. A purpose-designed online survey was used to examine the reliability of the comment bank. A total of 37 practice educators returned surveys, 31 of which were fully completed. Participants were asked to rate each individual comment using the five-point SPEF-R rating scale. One hundred and two of 109 comments demonstrated satisfactory agreement with their respective default ratings that were determined by the development team. At each domain level, the intra-class correlation coefficients (ranging between 0.86 and 0.96) also demonstrated good to excellent inter-rater reliability. There were only seven items that required rewording prior to inclusion in the final SPEF-R Online comment bank. The development of the SPEF-R Online comment bank offers a source of reliable comments (consistent with the SPEF-R rating scale across different domains) and aims to assist practice educators in providing reliable and timely feedback to students in a user-friendly manner. © 2014 Occupational Therapy Australia.

  20. Assessing cancer-specific anxiety in Chinese men with prostate cancer: psychometric evaluation of the Chinese version of the Memorial Anxiety Scale for Prostate Cancer (MAX-PC).

    PubMed

    Huang, Qingmei; Jiang, Ping; Zhang, Zijun; Luo, Jie; Dai, Yun; Zheng, Li; Wang, Wei

    2017-12-01

    The Memorial Anxiety Scale for Prostate Cancer (MAX-PC) was developed to identify and assess cancer-specific anxiety among men with prostate cancer (PCa); however, there is no Chinese version. The aim of our study was to translate the English version of MAX-PC into Chinese and evaluate the psychometric properties of it. The study cohort comprised 254 participants. Internal consistency including the Cronbach's alpha coefficient and item-total correlations were used to measure the reliability of the scale. Factor structure was analyzed by exploratory factor analysis and concurrent validity by comparing MAX-PC scores with anxiety subscale scores of the Hospital Anxiety and Depression Scale (HADS). Divergent validity was assessed by correlating MAX-PC with HADS depression subscale, while discriminant ability by comparing differences in MAX-PC scores between different patient groups. The Chinese version of MAX-PC demonstrated good reliability; the Cronbach's alpha coefficient for the total and three subscales (prostate cancer anxiety, PSA anxiety, and fear of recurrence) being 0.94, 0.93, 0.82, and 0.85, respectively. Exploratory factor analysis supported the three-factor structure of the scale established in the original version. Despite the somewhat underperformed divergent validity, the scale demonstrated good concurrent validity with a strong correlation with the HADS anxiety subscale (r = 0.71, p < 0.01). Moreover, discriminant ability was demonstrated by ability to differentiate between disease stages. The MAX-PC Chinese version was confirmed to be a valid, reliable instrument and is thus appropriate for identifying and quantifying cancer-specific anxiety in Chinese PCa patients.

  1. Reliability of the ECHOWS Tool for Assessment of Patient Interviewing Skills.

    PubMed

    Boissonnault, Jill S; Evans, Kerrie; Tuttle, Neil; Hetzel, Scott J; Boissonnault, William G

    2016-04-01

    History taking is an important component of patient/client management. Assessment of student history-taking competency can be achieved via a standardized tool. The ECHOWS tool has been shown to be valid with modest intrarater reliability in a previous study but did not demonstrate sufficient power to definitively prove its stability. The purposes of this study were: (1) to assess the reliability of the ECHOWS tool for student assessment of patient interviewing skills and (2) to determine whether the tool discerns between novice and experienced skill levels. A reliability and construct validity assessment was conducted. Three faculty members from the United States and Australia scored videotaped histories from standardized patients taken by students and experienced clinicians from each of these countries. The tapes were scored twice, 3 to 6 weeks apart. Reliability was assessed using interclass correlation coefficients (ICCs) and repeated measures. Analysis of variance models assessed the ability of the tool to discern between novice and experienced skill levels. The ECHOWS tool showed excellent intrarater reliability (ICC [3,1]=.74-.89) and good interrater reliability (ICC [2,1]=.55) as a whole. The summary of performance (S) section showed poor interrater reliability (ICC [2,1]=.27). There was no statistical difference in performance on the tool between novice and experienced clinicians. A possible ceiling effect may occur when standardized patients are not coached to provide complex and obtuse responses to interviewer questions. Variation in familiarity with the ECHOWS tool and in use of the online training may have influenced scoring of the S section. The ECHOWS tool demonstrates excellent intrarater reliability and moderate interrater reliability. Sufficient training with the tool prior to student assessment is recommended. The S section must evolve in order to provide a more discerning measure of interviewing skills. © 2016 American Physical Therapy Association.

  2. Creation and validation of the self-efficacy instrument for physical education teacher education majors toward inclusion.

    PubMed

    Block, Martin E; Hutzler, Yeshayahu; Barak, Sharon; Klavina, Aija

    2013-04-01

    The purpose was to validate a self-efficacy (SE) instrument toward including students with disability in physical education (PE). Three scales referring to intellectual disabilities (ID), physical disabilities (PD), or visual impairments (VI) were administered to 486 physical education teacher education (PETE) majors. The sample was randomly split, and exploratory and confirmatory factor analyses (EFA and CFA, respectively) were conducted. After deleting items that did not meet inclusion criteria, EFA item loadings ranged from 0.53 to 0.91, and Cronbach's alpha reliability was high (for ID = .86, PD = .90, and VI = .92). CFA showed that the ID scale demonstrated good goodness-of-fit, whereas in the PD and in the VI scales demonstrated moderate fit. Thus, the content and construct validity of the instrument was supported.

  3. Three-dimensional assessment of squats and drop jumps using the Microsoft Xbox One Kinect: Reliability and validity.

    PubMed

    Mentiplay, Benjamin F; Hasanki, Ksaniel; Perraton, Luke G; Pua, Yong-Hao; Charlton, Paula C; Clark, Ross A

    2018-03-01

    The Microsoft Xbox One Kinect™ (Kinect V2) contains a depth camera that can be used to manually identify anatomical landmark positions in three-dimensions independent of the standard skeletal tracking, and therefore has potential for low-cost, time-efficient three-dimensional movement analysis (3DMA). This study examined inter-session reliability and concurrent validity of the Kinect V2 for the assessment of coronal and sagittal plane kinematics for the trunk, hip and knee during single leg squats (SLS) and drop vertical jumps (DVJ). Thirty young, healthy participants (age = 23 ± 5yrs, male/female = 15/15) performed a SLS and DVJ protocol that was recorded concurrently by the Kinect V2 and 3DMA during two sessions, one week apart. The Kinect V2 demonstrated good to excellent reliability for all SLS and DVJ variables (ICC ≥ 0.73). Concurrent validity ranged from poor to excellent (ICC = 0.02 to 0.98) during the SLS task, although trunk, hip and knee flexion and two-dimensional measures of knee abduction and frontal plane projection angle all demonstrated good to excellent validity (ICC ≥ 0.80). Concurrent validity for the DVJ task was typically worse, with only two variables exceeding ICC = 0.75 (trunk and hip flexion). These findings indicate that the Kinect V2 may have potential for large-scale screening for ACL injury risk, however future prospective research is required.

  4. The measurement of threat orientations.

    PubMed

    Thompson, Suzanne C; Schlehofer, Michèle M; Bovin, Michelle J

    2006-01-01

    To develop measures of 3 threat orientations that affect responses to health behavior messages. In Study 1, college students (N = 47) completed items assessing threat orientations and health behaviors. In Study 2, college students and community adults (N = 110) completed the threat orientation items and measures of convergent and discriminant validity. In Study 1, the control-based, denial-based, and heightened-sensitivity-based threat orientation scales demonstrated good internal consistency and correlated with engagement in health behaviors. In Study 2, the convergent and discriminant validity of the 3 measures was established. The 3 scales have good internal reliability and construct validity.

  5. Factor structure, validity and reliability of the Cambridge Worry Scale in a pregnant population.

    PubMed

    Green, Josephine M; Kafetsios, Konstantinos; Statham, Helen E; Snowdon, Claire M

    2003-11-01

    This article presents the Cambridge Worry Scale (CWS), a content-based measure for assessing worries, and discusses its psychometric properties based on a longitudinal study of 1,207 pregnant women. Principal components analysis revealed a four-factor structure of women's concerns during pregnancy: socio-medical, own health, socio-economic and relational. The measure demonstrated good reliability and validity. Total CWS scores were strongly associated with state and trait anxiety (convergent validity) but also had significant and unique predictive value for mood outcomes (discriminant validity). The CWS discriminated better between women with different reproductive histories than measures of state and trait anxiety. We conclude that the CWS is a reliable and valid tool for assessing the extent and content of worries in specific situations.

  6. Validity and reliability of acoustic analysis of respiratory sounds in infants

    PubMed Central

    Elphick, H; Lancaster, G; Solis, A; Majumdar, A; Gupta, R; Smyth, R

    2004-01-01

    Objective: To investigate the validity and reliability of computerised acoustic analysis in the detection of abnormal respiratory noises in infants. Methods: Blinded, prospective comparison of acoustic analysis with stethoscope examination. Validity and reliability of acoustic analysis were assessed by calculating the degree of observer agreement using the κ statistic with 95% confidence intervals (CI). Results: 102 infants under 18 months were recruited. Convergent validity for agreement between stethoscope examination and acoustic analysis was poor for wheeze (κ = 0.07 (95% CI, –0.13 to 0.26)) and rattles (κ = 0.11 (–0.05 to 0.27)) and fair for crackles (κ = 0.36 (0.18 to 0.54)). Both the stethoscope and acoustic analysis distinguished well between sounds (discriminant validity). Agreement between observers for the presence of wheeze was poor for both stethoscope examination and acoustic analysis. Agreement for rattles was moderate for the stethoscope but poor for acoustic analysis. Agreement for crackles was moderate using both techniques. Within-observer reliability for all sounds using acoustic analysis was moderate to good. Conclusions: The stethoscope is unreliable for assessing respiratory sounds in infants. This has important implications for its use as a diagnostic tool for lung disorders in infants, and confirms that it cannot be used as a gold standard. Because of the unreliability of the stethoscope, the validity of acoustic analysis could not be demonstrated, although it could discriminate between sounds well and showed good within-observer reliability. For acoustic analysis, targeted training and the development of computerised pattern recognition systems may improve reliability so that it can be used in clinical practice. PMID:15499065

  7. The development and reliability of a simple field based screening tool to assess core stability in athletes.

    PubMed

    O'Connor, S; McCaffrey, N; Whyte, E; Moran, K

    2016-07-01

    To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Reliability of Lactation Assessment Tools Applied to Overweight and Obese Women.

    PubMed

    Chapman, Donna J; Doughty, Katherine; Mullin, Elizabeth M; Pérez-Escamilla, Rafael

    2016-05-01

    The interrater reliability of lactation assessment tools has not been evaluated in overweight/obese women. This study aimed to compare the interrater reliability of 4 lactation assessment tools in this population. A convenience sample of 45 women (body mass index > 27.0) was videotaped while breastfeeding (twice daily on days 2, 4, and 7 postpartum). Three International Board Certified Lactation Consultants independently rated each videotaped session using 4 tools (Infant Breastfeeding Assessment Tool [IBFAT], modified LATCH [mLATCH], modified Via Christi [mVC], and Riordan's Tool [RT]). For each day and tool, we evaluated interrater reliability with 1-way repeated-measures analyses of variance, intraclass correlation coefficients (ICCs), and percentage absolute agreement between raters. Analyses of variance showed significant differences between raters' scores on day 2 (all scales) and day 7 (RT). Intraclass correlation coefficient values reflected good (mLATCH) to excellent reliability (IBFAT, mVC, and RT) on days 2 and 7. All day 4 ICCs reflected good reliability. The ICC for mLATCH was significantly lower than all others on day 2 and was significantly lower than IBFAT (day 7). Percentage absolute interrater agreement for scale components ranged from 31% (day 2: observable swallowing, RT) to 92% (day 7: IBFAT, fixing; and mVC, latch time). Swallowing scores on all scales had the lowest levels of interrater agreement (31%-64%). We demonstrated differences in the interrater reliability of 4 lactation assessment tools when applied to overweight/obese women, with the lowest values observed on day 4. Swallowing assessment was particularly unreliable. Researchers and clinicians using these scales should be aware of the differences in their psychometric behavior. © The Author(s) 2015.

  9. Reliability of a quantitative clinical posture assessment tool among persons with idiopathic scoliosis.

    PubMed

    Fortin, Carole; Feldman, Debbie Ehrmann; Cheriet, Farida; Gravel, Denis; Gauthier, Frédérique; Labelle, Hubert

    2012-03-01

    To determine overall, test-retest and inter-rater reliability of posture indices among persons with idiopathic scoliosis. A reliability study using two raters and two test sessions. Tertiary care paediatric centre. Seventy participants aged between 10 and 20 years with different types of idiopathic scoliosis (Cobb angle 15 to 60°) were recruited from the scoliosis clinic. Based on the XY co-ordinates of natural reference points (e.g., eyes) as well as markers placed on several anatomical landmarks, 32 angular and linear posture indices taken from digital photographs in the standing position were calculated from a specially developed software program. Generalisability theory served to estimate the reliability and standard error of measurement (SEM) for the overall, test-retest and inter-rater designs. Bland and Altman's method was also used to document agreement between sessions and raters. In the random design, dependability coefficients demonstrated a moderate level of reliability for six posture indices (ϕ=0.51 to 0.72) and a good level of reliability for 26 posture indices out of 32 (ϕ≥0.79). Error attributable to marker placement was negligible for most indices. Limits of agreement and SEM values were larger for shoulder protraction, trunk list, Q angle, cervical lordosis and scoliosis angles. The most reproducible indices were waist angles and knee valgus and varus. Posture can be assessed in a global fashion from photographs in persons with idiopathic scoliosis. Despite the good reliability of marker placement, other studies are needed to minimise measurement errors in order to provide a suitable tool for monitoring change in posture over time. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  10. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer.

    PubMed

    Konge, L; Vilmann, P; Clementsen, P; Annema, J T; Ringsted, C

    2012-10-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliability and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC. A total of 30 patients with proven or suspected NSCLC underwent EUS - FNA for mediastinal staging by three trainees and three experienced physicians. Their performances were assessed prospectively by three experts in EUS under direct observation and again 2 months later in a blinded fashion using digital video-recordings. Based on the assessments, intra-rater reliability, inter-rater reliability, and construct validity were explored. The intra-rater reliability was good (Cronbach's α = 0.80), but comparison of results based on direct observations and blinded video-recordings indicated a significant bias favoring consultants (P = 0.022). Inter-rater reliability was very good (Cronbach's α = 0.93). However, one rater assessing five procedures or two raters each assessing four procedures were necessary to secure a generalizability coefficient of 0.80. The assessment tool demonstrated construct validity by discriminating between trainees and experienced physicians (P = 0.034). Competency in mediastinal staging of NSCLC using EUS and EUS - FNA can be assessed in a reliable and valid way using the EUSAT assessment tool. Measuring and defining competency and training requirements could improve EUS quality and benefit patient care. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Reliability and validity of the Microsoft Kinect for evaluating static foot posture

    PubMed Central

    2013-01-01

    Background The evaluation of foot posture in a clinical setting is useful to screen for potential injury, however disagreement remains as to which method has the greatest clinical utility. An inexpensive and widely available imaging system, the Microsoft Kinect™, may possess the characteristics to objectively evaluate static foot posture in a clinical setting with high accuracy. The aim of this study was to assess the intra-rater reliability and validity of this system for assessing static foot posture. Methods Three measures were used to assess static foot posture; traditional visual observation using the Foot Posture Index (FPI), a 3D motion analysis (3DMA) system and software designed to collect and analyse image and depth data from the Kinect. Spearman’s rho was used to assess intra-rater reliability and concurrent validity of the Kinect to evaluate foot posture, and a linear regression was used to examine the ability of the Kinect to predict total visual FPI score. Results The Kinect demonstrated moderate to good intra-rater reliability for four FPI items of foot posture (ρ = 0.62 to 0.78) and moderate to good correlations with the 3DMA system for four items of foot posture (ρ = 0.51 to 0.85). In contrast, intra-rater reliability of visual FPI items was poor to moderate (ρ = 0.17 to 0.63), and correlations with the Kinect and 3DMA systems were poor (absolute ρ = 0.01 to 0.44). Kinect FPI items with moderate to good reliability predicted 61% of the variance in total visual FPI score. Conclusions The majority of the foot posture items derived using the Kinect were more reliable than the traditional visual assessment of FPI, and were valid when compared to a 3DMA system. Individual foot posture items recorded using the Kinect were also shown to predict a moderate degree of variance in the total visual FPI score. Combined, these results support the future potential of the Kinect to accurately evaluate static foot posture in a clinical setting. PMID:23566934

  12. Development of a Chinese version of the Suicide Intent Scale.

    PubMed

    Gau, Susan S F; Chen, Chin-Hung; Lee, Charles T C; Chang, Jung-Chen; Cheng, Andrew T A

    2009-06-01

    This study established the psychometric properties of the Chinese version of the Suicide Intent Scale (SIS) in a clinic- and community-based sample of 36 patients and 592 respondents, respectively. Results showed that the Chinese SIS demonstrated good inter-rater and test-retest reliability. Factor analysis generated three factors (Precautions, Planning, and Seriousness) explaining 92.9% of the total variance with high internal consistency. It was moderately correlated with depressive symptoms. Results suggest that the Chinese SIS is a reliable and valid instrument for use in assessing the extent of suicidal intention among subjects with deliberate self-harm in ethnic Chinese populations.

  13. Analysis of reliable sub-ns spin-torque switching under transverse bias magnetic fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Aquino, M., E-mail: daquino@uniparthenope.it; Perna, S.; Serpico, C.

    2015-05-07

    The switching process of a magnetic spin-valve nanosystem subject to spin-polarized current pulses is considered. The dependence of the switching probability on the current pulse duration is investigated. The further application of a transverse field along the intermediate anisotropy axis of the particle is used to control the quasi-random relaxation of magnetization to the reversed magnetization state. The critical current amplitudes to realize the switching are determined by studying the phase portrait of the Landau-Lifshtz-Slonczewski dynamics. Macrospin numerical simulations are in good agreement with the theoretical prediction and demonstrate reliable switching even for very short (below 100 ps) current pulses.

  14. Reliability and validity of the Wolfram Unified Rating Scale (WURS)

    PubMed Central

    2012-01-01

    Background Wolfram syndrome (WFS) is a rare, neurodegenerative disease that typically presents with childhood onset insulin dependent diabetes mellitus, followed by optic atrophy, diabetes insipidus, deafness, and neurological and psychiatric dysfunction. There is no cure for the disease, but recent advances in research have improved understanding of the disease course. Measuring disease severity and progression with reliable and validated tools is a prerequisite for clinical trials of any new intervention for neurodegenerative conditions. To this end, we developed the Wolfram Unified Rating Scale (WURS) to measure the severity and individual variability of WFS symptoms. The aim of this study is to develop and test the reliability and validity of the Wolfram Unified Rating Scale (WURS). Methods A rating scale of disease severity in WFS was developed by modifying a standardized assessment for another neurodegenerative condition (Batten disease). WFS experts scored the representativeness of WURS items for the disease. The WURS was administered to 13 individuals with WFS (6-25 years of age). Motor, balance, mood and quality of life were also evaluated with standard instruments. Inter-rater reliability, internal consistency reliability, concurrent, predictive and content validity of the WURS were calculated. Results The WURS had high inter-rater reliability (ICCs>.93), moderate to high internal consistency reliability (Cronbach’s α = 0.78-0.91) and demonstrated good concurrent and predictive validity. There were significant correlations between the WURS Physical Assessment and motor and balance tests (rs>.67, p<.03), between the WURS Behavioral Scale and reports of mood and behavior (rs>.76, p<.04) and between WURS Total scores and quality of life (rs=-.86, p=.001). The WURS demonstrated acceptable content validity (Scale-Content Validity Index=0.83). Conclusions These preliminary findings demonstrate that the WURS has acceptable reliability and validity and captures individual differences in disease severity in children and young adults with WFS. PMID:23148655

  15. Scale for positive aspects of caregiving experience: development, reliability, and factor structure.

    PubMed

    Kate, N; Grover, S; Kulhara, P; Nehra, R

    2012-06-01

    OBJECTIVE. To develop an instrument (Scale for Positive Aspects of Caregiving Experience [SPACE]) that evaluates positive caregiving experience and assess its psychometric properties. METHODS. Available scales which assess some aspects of positive caregiving experience were reviewed and a 50-item questionnaire with a 5-point rating was constructed. In all, 203 primary caregivers of patients with severe mental disorders were asked to complete the questionnaire. Internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity were evaluated. Principal component factor analysis was run to assess the factorial validity of the scale. RESULTS. The scale developed as part of the study was found to have good internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity. Principal component factor analysis yielded a 4-factor structure, which also had good test-retest reliability and cross-language reliability. There was a strong correlation between the 4 factors obtained. CONCLUSION. The SPACE developed as part of this study has good psychometric properties.

  16. Development and validation of PediaTrac™: A web-based tool to track developing infants.

    PubMed

    Lajiness-O'Neill, Renée; Brooks, Judith; Lukomski, Angela; Schilling, Stephen; Huth-Bocks, Alissa; Warschausky, Seth; Flores, Ana-Mercedes; Swick, Casey; Nyman, Tristin; Andersen, Tiffany; Morris, Natalie; Schmitt, Thomas A; Bell-Smith, Jennifer; Moir, Barbara; Hodges, Elise K; Lyddy, James E

    2018-02-01

    PediaTrac™, a 363-item web-based tool to track infant development, administered in modules of ∼40-items per sampling period, newborn (NB), 2--, 4--, 6--, 9-- and 12--months was validated. Caregivers answered demographic, medical, and environmental questions, and questions covering the sensorimotor, feeding/eating, sleep, speech/language, cognition, social-emotional, and attachment domains. Expert Panel Reviews and Cognitive Interviews (CI) were conducted to validate the item bank. Classical Test Theory (CTT) and Item Response Theory (IRT) methods were employed to examine the dimensionality and psychometric properties of PediaTrac with pooled longitudinal and cross-sectional cohorts (N = 132). Intraclass correlation coefficients (ICC) for the Expert Panel Review revealed moderate agreement at 6 -months and good reliability at other sampling periods. ICC estimates for CI revealed moderate reliability regarding clarity of the items at NB and 4 months, good reliability at 2--, 9-- and 12--months and excellent reliability at 6 -months. CTT revealed good coefficient alpha estimates (α ≥ 0.77 for five of the six ages) for the Social-Emotional/Communication, Attachment (α ≥ 0.89 for all ages), and Sensorimotor (α ≥ 0.75 at 6-months) domains, revealing the need for better targeting of sensorimotor items. IRT modeling revealed good reliability (r = 0.85-0.95) for three distinct domains (Feeding/Eating, Social-Emotional/Communication and Attachment) and four subdomains (Feeding Breast/Formula, Feeding Solid Food, Social-Emotional Information Processing, Communication/Cognition). Convergent and discriminant construct validity were demonstrated between our IRT-modeled domains and constructs derived from existing developmental, behavioral and caregiver measures. Our Attachment domain was significantly correlated with existing measures at the NB and 2-month periods, while the Social-Emotional/Communication domain was highly correlated with similar constructs at the 6-, 9- and 12-month periods. PediaTrac has potential for producing novel and effective estimates of infant development via the Sensorimotor, Feeding/Eating, Social-Emotional/Communication and Attachment domains. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers.

    PubMed

    Lohr, Christine; Braumann, Klaus-Michael; Reer, Ruediger; Schroeder, Jan; Schmidt, Tobias

    2018-04-20

    Tensiomyography™ (TMG) and MyotonPRO ® (MMT) are two non-invasive devices for monitoring muscle contractile and mechanical characteristics. This study aimed to evaluate the test-retest reliability of TMG and MMT parameters for measuring (TMG:) muscle displacement (D m ), contraction time (T c ), and velocity (V c ) and (MMT:) frequency (F), stiffness (S), and decrement (D) of the erector spinae muscles (ES) in healthy adults. A particular focus was set on the establishment of reliability measures for the previously barely evaluated secondary TMG parameter V c . Twenty-four subjects (13 female and 11 male, mean ± SD, 38.0 ± 12.0 years) were measured using TMG and MMT over 2 consecutive days. Absolute and relative reliability was calculated by standard error of measurement (SEM, SEM%), Minimum detectable change (MDC, MDC%), coefficient of variation (CV%) and intraclass correlation coefficient (ICC, 3.1) with a 95% confidence interval (CI). The ICCs for all variables and test-retest intervals ranged from 0.75 to 0.99 indicating a good to excellent relative reliability for both TMG and MMT, demonstrating the lowest values for TMG T c and between-day MMT D (ICC < 0.90). Absolute reliability was suitable for all parameters (CV 2-8%) except for D m (10-12%). V c demonstrated to be the most reliable and repeatable TMG parameter (ICC > 0.95, CV < 8%). The reliability for TMG V c could be established successfully. Its further applicability needs to be confirmed in future studies. MMT was found to be more reliable on repeated testing than the two other TMG parameters D m and T c .

  18. Language-Specific Attention Treatment for Aphasia: Description and Preliminary Findings.

    PubMed

    Peach, Richard K; Nathan, Meghana R; Beck, Katherine M

    2017-02-01

    The need for a specific, language-based treatment approach to aphasic impairments associated with attentional deficits is well documented. We describe language-specific attention treatment, a specific skill-based approach for aphasia that exploits increasingly complex linguistic tasks that focus attention. The program consists of eight tasks, some with multiple phases, to assess and treat lexical and sentence processing. Validation results demonstrate that these tasks load on six attentional domains: (1) executive attention; (2) attentional switching; (3) visual selective attention/processing speed; (4) sustained attention; (5) auditory-verbal working memory; and (6) auditory processing speed. The program demonstrates excellent inter- and intrarater reliability and adequate test-retest reliability. Two of four people with aphasia exposed to this program demonstrated good language recovery whereas three of the four participants showed improvements in auditory-verbal working memory. The results provide support for this treatment program in patients with aphasia having no greater than a moderate degree of attentional impairment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Test-retest reliability of the irrational performance beliefs inventory.

    PubMed

    Turner, M J; Slater, M J; Dixon, J; Miller, A

    2018-02-01

    The irrational performance beliefs inventory (iPBI) was developed to measure irrational beliefs within performance domains such as sport, academia, business, and the military. Past research indicates that the iPBI has good construct, concurrent, and predictive validity, but the test-retest reliability of the iPBI has not yet been examined. Therefore, in the present study the iPBI was administered to university sport and exercise students (n = 160) and academy soccer athletes (n = 75) at three-time points. Time point two occurred 7 days after time point one, and time point three occurred 21 days after time point two. In addition, social desirability was also measured. Repeated-measures MANCOVAs, intra-class coefficients, and Pearson's (r) correlations demonstrate that the iPBI has good test-retest reliability, with iPBI scores remaining stable across the three-time points. Pearson's correlation coefficients revealed no relationships between the iPBI and social desirability, indicating that the iPBI is not highly susceptible to response bias. The results are discussed with reference to the continued usage and development of the iPBI, and future research recommendations relating to the investigation of irrational performance beliefs are proposed.

  20. Reliability and validity of a Chinese version of the Diagnostic Interview for Borderlines-Revised.

    PubMed

    Wang, Lanlan; Yuan, Chenmei; Qiu, Jianying; Gunderson, John; Zhang, Min; Jiang, Kaida; Leung, Freedom; Zhong, Jie; Xiao, Zeping

    2014-09-01

    Borderline personality disorder (BPD) is the most studied of the axis II disorders. One of the most widely used diagnostic instruments is the Diagnostic Interview for Borderline Patients-Revised (DIB-R). The aim of this study was to test the reliability and validity of DIB-R for use in the Chinese culture. The reliability and validity of the DIB-R Chinese version were assessed in a sample of 236 outpatients with a probable BPD diagnosis. The Structured Clinical Interview for DSM-IV Personality Disorders (SCID-II) was used as a standard. Test-retest reliability was tested six months later with 20 patients, and inter-rater reliability was tested on 32 patients. The Chinese version of the DIB-R showed good internal global consistency (Cronbach's α of 0.916), good test-retest reliability (Pearson correlation of 0.704), good inter-rater reliability (intra-class correlation coefficient of 0.892 and kappa of 0.861). When compared with the DSM-IV diagnosis as measured by the SCID-II, the DIB-R showed relatively good sensitivity (0.768) and specificity (0.891) at the cutoff of 7, moderate diagnostic convergence (kappa of 0.631), as well as good discriminating validity. The Chinese version of the DIB-R has good psychometric properties, which renders it a valuable method for examining the presence, the severity, and component phenotypes of BPD in Chinese samples. © 2013 Wiley Publishing Asia Pty Ltd.

  1. On the reliability of seasonal climate forecasts.

    PubMed

    Weisheimer, A; Palmer, T N

    2014-07-06

    Seasonal climate forecasts are being used increasingly across a range of application sectors. A recent UK governmental report asked: how good are seasonal forecasts on a scale of 1-5 (where 5 is very good), and how good can we expect them to be in 30 years time? Seasonal forecasts are made from ensembles of integrations of numerical models of climate. We argue that 'goodness' should be assessed first and foremost in terms of the probabilistic reliability of these ensemble-based forecasts; reliable inputs are essential for any forecast-based decision-making. We propose that a '5' should be reserved for systems that are not only reliable overall, but where, in particular, small ensemble spread is a reliable indicator of low ensemble forecast error. We study the reliability of regional temperature and precipitation forecasts of the current operational seasonal forecast system of the European Centre for Medium-Range Weather Forecasts, universally regarded as one of the world-leading operational institutes producing seasonal climate forecasts. A wide range of 'goodness' rankings, depending on region and variable (with summer forecasts of rainfall over Northern Europe performing exceptionally poorly) is found. Finally, we discuss the prospects of reaching '5' across all regions and variables in 30 years time.

  2. Validity and reliability of the robotic objective structured assessment of technical skills

    PubMed Central

    Siddiqui, Nazema Y.; Galloway, Michael L.; Geller, Elizabeth J.; Green, Isabel C.; Hur, Hye-Chun; Langston, Kyle; Pitter, Michael C.; Tarr, Megan E.; Martino, Martin A.

    2015-01-01

    Objective Objective structured assessments of technical skills (OSATS) have been developed to measure the skill of surgical trainees. Our aim was to develop an OSATS specifically for trainees learning robotic surgery. Study Design This is a multi-institutional study in eight academic training programs. We created an assessment form to evaluate robotic surgical skill through five inanimate exercises. Obstetrics/gynecology, general surgery, and urology residents, fellows, and faculty completed five robotic exercises on a standard training model. Study sessions were recorded and randomly assigned to three blinded judges who scored performance using the assessment form. Construct validity was evaluated by comparing scores between participants with different levels of surgical experience; inter- and intra-rater reliability were also assessed. Results We evaluated 83 residents, 9 fellows, and 13 faculty, totaling 105 participants; 88 (84%) were from obstetrics/gynecology. Our assessment form demonstrated construct validity, with faculty and fellows performing significantly better than residents (mean scores: 89 ± 8 faculty; 74 ± 17 fellows; 59 ± 22 residents, p<0.01). In addition, participants with more robotic console experience scored significantly higher than those with fewer prior console surgeries (p<0.01). R-OSATS demonstrated good inter-rater reliability across all five drills (mean Cronbach's α: 0.79 ± 0.02). Intra-rater reliability was also high (mean Spearman's correlation: 0.91 ± 0.11). Conclusions We developed an assessment form for robotic surgical skill that demonstrates construct validity, inter- and intra-rater reliability. When paired with standardized robotic skill drills this form may be useful to distinguish between levels of trainee performance. PMID:24807319

  3. The reliability of the Glasgow Coma Scale: a systematic review.

    PubMed

    Reith, Florence C M; Van den Brande, Ruben; Synnot, Anneliese; Gruen, Russell; Maas, Andrew I R

    2016-01-01

    The Glasgow Coma Scale (GCS) provides a structured method for assessment of the level of consciousness. Its derived sum score is applied in research and adopted in intensive care unit scoring systems. Controversy exists on the reliability of the GCS. The aim of this systematic review was to summarize evidence on the reliability of the GCS. A literature search was undertaken in MEDLINE, EMBASE and CINAHL. Observational studies that assessed the reliability of the GCS, expressed by a statistical measure, were included. Methodological quality was evaluated with the consensus-based standards for the selection of health measurement instruments checklist and its influence on results considered. Reliability estimates were synthesized narratively. We identified 52 relevant studies that showed significant heterogeneity in the type of reliability estimates used, patients studied, setting and characteristics of observers. Methodological quality was good (n = 7), fair (n = 18) or poor (n = 27). In good quality studies, kappa values were ≥0.6 in 85%, and all intraclass correlation coefficients indicated excellent reliability. Poor quality studies showed lower reliability estimates. Reliability for the GCS components was higher than for the sum score. Factors that may influence reliability include education and training, the level of consciousness and type of stimuli used. Only 13% of studies were of good quality and inconsistency in reported reliability estimates was found. Although the reliability was adequate in good quality studies, further improvement is desirable. From a methodological perspective, the quality of reliability studies needs to be improved. From a clinical perspective, a renewed focus on training/education and standardization of assessment is required.

  4. The reliability and validity of a child and adolescent participation in decision-making questionnaire.

    PubMed

    O'Hare, L; Santin, O; Winter, K; McGuinness, C

    2016-09-01

    There is a growing impetus across the research, policy and practice communities for children and young people to participate in decisions that affect their lives. Furthermore, there is a dearth of general instruments that measure children and young people's views on their participation in decision-making. This paper presents the reliability and validity of the Child and Adolescent Participation in Decision-Making Questionnaire (CAP-DMQ) and specifically looks at a population of looked-after children, where a lack of participation in decision-making is an acute issue. The participants were 151 looked after children and adolescents between 10-23 years of age who completed the 10 item CAP-DMQ. Of the participants 113 were in receipt of an advocacy service that had an aim of increasing participation in decision-making with the remaining participants not having received this service. The results showed that the CAP-DMQ had good reliability (Cronbach's alpha = 0.94) and showed promising uni-dimensional construct validity through an exploratory factor analysis. The items in the CAP-DMQ also demonstrated good content validity by overlapping with prominent models of child and adolescent participation (Lundy 2007) and decision-making (Halpern 2014). A regression analysis showed that age and gender were not significant predictors of CAP-DMQ scores but receipt of advocacy was a significant predictor of scores (effect size d = 0.88), thus showing appropriate discriminant criterion validity. Overall, the CAP-DMQ showed good reliability and validity. Therefore, the measure has excellent promise for theoretical investigation in the area of child and adolescent participation in decision-making and equally shows empirical promise for use as a measure in evaluating services, which have increasing the participation of children and adolescents in decision-making as an intended outcome. © 2016 John Wiley & Sons Ltd.

  5. Developing an Acceptability Assessment of Preventive Dental Treatments

    PubMed Central

    Hyde, Susan; Gansky, Stuart A.; Gonzalez-Vargas, Maria J.; Husting, Sheila R.; Cheng, Nancy F.; Millstein, Susan G.; Adams, Sally H.

    2012-01-01

    Objectives Early childhood caries (ECC) is very prevalent among young Hispanic children. ECC is amenable to a variety of preventive procedures, yet many Hispanic families underutilize dental services. Acceptability research may assist in health care planning and resource allocation by identifying patient preferences among efficacious treatments with the goal of improving their utilization. The purposes of this study were (a) to develop a culturally competent acceptability assessment instrument, directed toward the caregivers of young Hispanic children, for five preventive dental treatments for ECC and (b) to test the instrument's reliability and validity. Methods An instrument of five standard treatments known to prevent ECC was developed, translated, reviewed by focus groups, and pilot tested, then tested for reliability. The instrument included illustrated cards, brief video clips, and samples of the treatments and was culturally appropriate for low-income Hispanic caregivers. In addition to determining the acceptability of the five treatments individually, the treatments were also presented as paired comparisons. Results Focus groups and debriefing interviews following the pilot tests established that the instrument has good face validity. The illustrated cards, product samples, and video demonstrations of the five treatments resulted in an instrument possessing good content validity. The instrument has good to excellent test–retest reliability, with identical time 1–time 2 responses for each of the five treatments 92 percent of the time (range 87 to 97 percent), and the same treatment of the paired comparisons preferred 75 percent of the time (range 61 to 90 percent). Conclusions The acceptability instrument described is reliable and valid and may be useful in program planning efforts to identify and increase the utilization of preferred ECC preventive treatments for target populations. PMID:18662256

  6. Developing an acceptability assessment of preventive dental treatments.

    PubMed

    Hyde, Susan; Gansky, Stuart A; Gonzalez-Vargas, Maria J; Husting, Sheila R; Cheng, Nancy F; Millstein, Susan G; Adams, Sally H

    2009-01-01

    Early childhood caries (ECC) is very prevalent among young Hispanic children. ECC is amenable to a variety of preventive procedures, yet many Hispanic families underutilize dental services. Acceptability research may assist in health care planning and resource allocation by identifying patient preferences among efficacious treatments with the goal of improving their utilization. The purposes of this study were (a) to develop a culturally competent acceptability assessment instrument, directed toward the caregivers of young Hispanic children, for five preventive dental treatments for ECC and (b) to test the instrument's reliability and validity. An instrument of five standard treatments known to prevent ECC was developed, translated, reviewed by focus groups, and pilot tested, then tested for reliability The instrument included illustrated cards, brief video clips, and samples of the treatments and was culturally appropriate for low-income Hispanic caregivers. In addition to determining the acceptability of the five treatments individually, the treatments were also presented as paired comparisons. Focus groups and debriefing interviews following the pilot tests established that the instrument has good face validity. The illustrated cards, product samples, and video demonstrations of the five treatments resulted in an instrument possessing good content validity. The instrument has good to excellent test-retest reliability, with identical time 1-time 2 responses for each of the five treatments 92 percent of the time (range 87 to 97 percent), and the same treatment of the paired comparisons preferred 75 percent of the time (range 61 to 90 percent). The acceptability instrument described is reliable and valid and may be useful in program planning efforts to identify and increase the utilization of preferred ECC preventive treatments for target populations.

  7. Translation, validity and reliability of the British Sign Language (BSL) version of the EQ-5D-5L.

    PubMed

    Rogers, Katherine D; Pilling, Mark; Davies, Linda; Belk, Rachel; Nassimi-Green, Catherine; Young, Alys

    2016-07-01

    To translate the health questionnaire EuroQol EQ-5D-5L into British Sign Language (BSL), to test its reliability with the signing Deaf population of BSL users in the UK and to validate its psychometric properties. The EQ-5D-5L BSL was developed following the international standard for translation required by EuroQol, with additional agreed features appropriate to a visual language. Data collection used an online platform to view the signed (BSL) version of the tests. The psychometric testing included content validity, assessed by interviewing a small sample of Deaf people. Reliability was tested by internal consistency of the items and test-retest, and convergent validity was assessed by determining how well EQ-5D-5L BSL correlates with CORE-10 BSL and CORE-6D BSL. The psychometric properties of the EQ-5D-5L BSL are good, indicating that it can be used to measure health status in the Deaf signing population in the UK. Convergent validity between EQ-5D-5L BSL and CORE-10 BSL and CORE-6D BSL is consistent, demonstrating that the BSL version of EQ-5D-5L is a good measure of the health status of an individual. The test-retest reliability of EQ-5D-5L BSL, for each dimension of health, was shown to have Cohen's kappa values of 0.47-0.61; these were in the range of moderate to good and were therefore acceptable. This is the first time EQ-5D-5L has been translated into a signed language for use with Deaf people and is a significant step forward towards conducting studies of health status and cost-effectiveness in this population.

  8. Psychometric Properties of the Chinese Version of the Eating Attitudes Test in Young Female Patients with Eating Disorders in Mainland China.

    PubMed

    Kang, Qing; Chan, Raymond C K; Li, Xiaoping; Arcelus, Jon; Yue, Ling; Huang, Jiabin; Gu, Lian; Fan, Qing; Zhang, Haiyin; Xiao, Zeping; Chen, Jue

    2017-11-01

    The study aimed to investigate the reliability and validity of the Chinese version of the eating attitudes test (EAT-26) among female adolescents and young adults in Mainland China. This scale was administered to 396 female eating disorder patients and 406 noneating disorder healthy controls, in addition 35 healthy controls completed a retest after a 4-week intervals. Tests for reliability, convergent validity and receiver operating characteristic analysis were performed to detect the psychometric properties. The EAT-26 demonstrated good internal consistency (Cronbach's alpha = 0.822-0.922), test-retest reliability (interclass correlation coefficient = 0.817) and convergent validity(r = 0.450-0.750). The receiver operating characteristic analysis showed that the cut-off 14 for anorexia nervosa and 15 for bulimia nervosa represented good compromises with approximate sensitivity (0.66-0.68) and specificity (0.85-0.86). Our findings provided evidence that the Chinese version of the EAT-26 was a psychometrically reliable and valid self-rating instrument for identifying people suffering from an eating disorder in Mainland China. A clinical cut-off range between 14 and 15 could be used, but caution should be exercised because of the low sensitivity of the tool. Copyright © 2017 John Wiley & Sons, Ltd and Eating Disorders Association. Copyright © 2017 John Wiley & Sons, Ltd and Eating Disorders Association.

  9. Validation of the Middlesex Elderly Assessment of Mental State (MEAMS) as a cognitive screening test in patients with acquired brain injury in Turkey.

    PubMed

    Kutlay, Sehim; Kuçukdeveci, Ayse A; Elhan, Atilla H; Yavuzer, Gunes; Tennant, Alan

    2007-02-28

    Assessment of cognitive impairment with a valid cognitive screening tool is essential in neurorehabilitation. The aim of this study was to test the reliability and validity of the Turkish-adapted version of the Middlesex Elderly Assessment of Mental State (MEAMS) among acquired brain injury patients in Turkey. Some 155 patients with acquired brain injury admitted for rehabilitation were assessed by the adapted version of MEAMS at admission and discharge. Reliability was tested by internal consistency, intra-class correlation coefficient (ICC) and person separation index; internal construct validity by Rasch analysis; external construct validity by associations with physical and cognitive disability (FIM); and responsiveness by Effect Size. Reliability was found to be good with Cronbach's alpha of 0.82 at both admission and discharge; and likewise an ICC of 0.80. Person separation index was 0.813. Internal construct validity was good by fit of the data to the Rasch model (mean item fit -0.178; SD 1.019). Items were substantially free of differential item functioning. External construct validity was confirmed by expected associations with physical and cognitive disability. Effect size was 0.42 compared with 0.22 for cognitive FIM. The reliability and validity of the Turkish version of MEAMS as a cognitive impairment screening tool in acquired brain injury has been demonstrated.

  10. Reliability of Neurobehavioral Assessments from Birth to Term Equivalent Age in Preterm and Term Born Infants.

    PubMed

    Eeles, Abbey L; Olsen, Joy E; Walsh, Jennifer M; McInnes, Emma K; Molesworth, Charlotte M L; Cheong, Jeanie L Y; Doyle, Lex W; Spittle, Alicia J

    2017-02-01

    Neurobehavioral assessments provide insight into the functional integrity of the developing brain and help guide early intervention for preterm (<37 weeks' gestation) infants. In the context of shorter hospital stays, clinicians often need to assess preterm infants prior to term equivalent age. Few neurobehavioral assessments used in the preterm period have established interrater reliability. To evaluate the interrater reliability of the Hammersmith Neonatal Neurological Examination (HNNE) and the NICU Network Neurobehavioral Scale (NNNS), when used both preterm and at term (>36 weeks). Thirty-five preterm infants and 11 term controls were recruited. Five assessors double-scored the HNNE and NNNS administered either preterm or at term. A one-way random effects, absolute, single-measures interclass correlation coefficient (ICC) was calculated to determine interrater reliability. Interrater reliability for the HNNE was excellent (ICC > 0.74) for optimality scores, and good (ICC 0.60-0.74) to excellent for subtotal scores, except for 'Tone Patterns' (ICC 0.54). On the NNNS, interrater reliability was predominantly excellent for all items. Interrater agreement was generally excellent at both time points. Overall, the HNNE and NNNS neurobehavioral assessments demonstrated mostly excellent interrater reliability when used prior to term and at term.

  11. Reliability and Validity of the Behavioral Addiction Measure for Video Gaming.

    PubMed

    Sanders, James L; Williams, Robert J

    2016-01-01

    Most tests of video game addiction have weak construct validity and limited ability to correctly identify people in denial. The purpose of the present research was to investigate the reliability and validity of a new test of video game addiction (Behavioral Addiction Measure-Video Gaming [BAM-VG]) that was developed in part to address these deficiencies. Regular adult video gamers (n = 506) were recruited from a Canadian online panel and completed a survey containing three measures of excessive video gaming (BAM-VG; DSM-5 criteria for Internet Gaming Disorder [IGD]; and the IGD-20), as well as questions concerning extensiveness of video game involvement and self-report of problems associated with video gaming. One month later, they were reassessed for the purposes of establishing test-retest reliability. The BAM-VG demonstrated good internal consistency as well as 1 month test-retest reliability. Criterion-related validity was demonstrated by significant correlations with the following: time spent playing, self-identification of video game problems, and scores on other instruments designed to assess video game addiction (DSM-5 IGD, IGD-20). Consistent with the theory, principal component analysis identified two components underlying the BAM-VG that roughly correspond with impaired control and significant negative consequences deriving from this impaired control. Together with its excellent construct validity and other technical features, the BAM-VG represents a reliable and valid test of video game addiction.

  12. [The appraisal of reliability and validity of subjective workload assessment technique and NASA-task load index].

    PubMed

    Xiao, Yuan-mei; Wang, Zhi-ming; Wang, Mian-zhen; Lan, Ya-jia

    2005-06-01

    To test the reliability and validity of two mental workload assessment scales, i.e. subjective workload assessment technique (SWAT) and NASA task load index (NASA-TLX). One thousand two hundred and sixty-eight mental workers were sampled from various kinds of occupations, such as scientific research, education, administration and medicine, etc, with randomized cluster sampling. The re-test reliability, split-half reliability, Cronbach's alpha coefficient and correlation coefficients between item score and total score were adopted to test the reliability. The test of validity included structure validity. The re-test reliability coefficients of these two scales and their items were ranged from 0.516 to 0.753 (P < 0.01), indicating the two scales had good re-test reliability; the split-half reliability of SWAT was 0.645, and its Cronbach's alpha coefficient was more than 0.80, all the correlation coefficients between its items score and total score were more than 0.70; as for NASA-TLX, both the split-half reliability and Cronbach's alpha coefficient were more than 0.80, the correlation coefficients between its items score and total score were all more than 0.60 (P < 0.01) except the item of performance. Both scales had good inner consistency. The Pearson correlation coefficient between the two scales was 0.492 (P < 0.01), implying the results of the two scales had good consistency. Factor analysis showed that the two scales had good structure validity. Both SWAT and NASA-TLX have good reliability and validity and may be used as a valid tool to assess mental workload in China after being revised properly.

  13. Validation of an Empathy Scale in Pharmacy and Nursing Students

    PubMed Central

    Chen, Aleda M. H.; Yehle, Karen S.; Plake, Kimberly S.

    2013-01-01

    Objective. To validate an empathy scale to measure empathy in pharmacy and nursing students. Methods. A 15-item instrument comprised of the cognitive and affective empathy domains, was created. Each item was rated using a 7-point Likert scale, ranging from strongly disagree to strongly agree. Concurrent validity was demonstrated with the Jefferson Scale of Empathy – Health Professional Students (JSE-HPS). Results. Reliability analysis of data from 216 students (pharmacy, N=158; nursing, N=58) showed that scores on the empathy scale were positively associated with JSE-HPS scores (p<0.001). Factor analysis confirmed that 14 of the 15 items were significantly associated with their respective domain, but the overall instrument had limited goodness of fit. Conclusions. Results of this study demonstrate the reliability and validity of a new scale for evaluating student empathy. Further testing of the scale at other universities is needed to establish validity. PMID:23788805

  14. Development and Validation of a Measure of Quality of Life for the Young Elderly in Sri Lanka.

    PubMed

    de Silva, Sudirikku Hennadige Padmal; Jayasuriya, Anura Rohan; Rajapaksa, Lalini Chandika; de Silva, Ambepitiyawaduge Pubudu; Barraclough, Simon

    2016-01-01

    Sri Lanka has one of the fastest aging populations in the world. Measurement of quality of life (QoL) in the elderly needs instruments developed that encompass the sociocultural settings. An instrument was developed to measure QoL in the young elderly in Sri Lanka (QLI-YES), using accepted methods to generate and reduce items. The measure was validated using a community sample. Construct, criterion and predictive validity and reliability were tested. A first-order model of 24 items with 6 domains was found to have good fit indices (CMIN/df = 1.567, RMR = 0.05, CFI = 0.95, and RMSEA = 0.053). Both criterion and predictive validity were demonstrated. Good internal consistency reliability (Cronbach's α = 0.93) was shown. The development of the QLI-YES using a societal perspective relevant to the social and cultural beliefs has resulted in a robust and valid instrument to measure QoL for the young elderly in Sri Lanka. © 2015 APJPH.

  15. Confirmatory Factor Analysis of the Combined Social Phobia Scale and Social Interaction Anxiety Scale: Support for a Bifactor Model.

    PubMed

    Gomez, Rapson; Watson, Shaun D

    2017-01-01

    For the Social Phobia Scale (SPS) and the Social Interaction Anxiety Scale (SIAS) together, this study examined support for a bifactor model, and also the internal consistency reliability and external validity of the factors in this model. Participants ( N = 526) were adults from the general community who completed the SPS and SIAS. Confirmatory factor analysis (CFA) of their ratings indicated good support for the bifactor model. For this model, the loadings for all but six items were higher on the general factor than the specific factors. The three positively worded items had negligible loadings on the general factor. The general factor explained most of the common variance in the SPS and SIAS, and demonstrated good model-based internal consistency reliability (omega hierarchical) and a strong association with fear of negative evaluation and extraversion. The practical implications of the findings for the utilization of the SPS and SIAS, and the theoretical and clinical implications for social anxiety are discussed.

  16. Confirmatory Factor Analysis of the Combined Social Phobia Scale and Social Interaction Anxiety Scale: Support for a Bifactor Model

    PubMed Central

    Gomez, Rapson; Watson, Shaun D.

    2017-01-01

    For the Social Phobia Scale (SPS) and the Social Interaction Anxiety Scale (SIAS) together, this study examined support for a bifactor model, and also the internal consistency reliability and external validity of the factors in this model. Participants (N = 526) were adults from the general community who completed the SPS and SIAS. Confirmatory factor analysis (CFA) of their ratings indicated good support for the bifactor model. For this model, the loadings for all but six items were higher on the general factor than the specific factors. The three positively worded items had negligible loadings on the general factor. The general factor explained most of the common variance in the SPS and SIAS, and demonstrated good model-based internal consistency reliability (omega hierarchical) and a strong association with fear of negative evaluation and extraversion. The practical implications of the findings for the utilization of the SPS and SIAS, and the theoretical and clinical implications for social anxiety are discussed. PMID:28210232

  17. The Motivation and Pleasure Scale-Self-Report (MAP-SR): reliability and validity of a self-report measure of negative symptoms.

    PubMed

    Llerena, Katiah; Park, Stephanie G; McCarthy, Julie M; Couture, Shannon M; Bennett, Melanie E; Blanchard, Jack J

    2013-07-01

    The Clinical Assessment Interview for Negative Symptoms (CAINS) is an empirically developed interview measure of negative symptoms. Building on prior work, this study examined the reliability and validity of a self-report measure based on the CAINS-the Motivation and Pleasure Scale-Self-Report (MAP-SR)-that assesses the motivation and pleasure domain of negative symptoms. Thirty-seven participants with schizophrenia or schizoaffective disorder completed the 18-item MAP-SR, the CAINS, and other measures of functional outcome. Item analyses revealed three items that performed poorly. The revised 15-item MAP-SR demonstrated good internal consistency and convergent validity with the clinician-rated Motivation and Pleasure scale of the CAINS, as well as good discriminant validity, with little association with psychotic symptoms or depression/anxiety. MAP-SR scores were related to social anhedonia, social closeness, and clinician-rated social functioning. The MAP-SR is a promising self-report measure of severity of negative symptoms. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Validation of a short measure of effort-reward imbalance in the workplace: evidence from China.

    PubMed

    Li, Jian; Loerbroks, Adrian; Shang, Li; Wege, Natalia; Wahrendorf, Morten; Siegrist, Johannes

    2012-01-01

    Work stress is an emergent risk in occupational health in China, and its measurement is still a critical issue. The aim of this study was to examine the reliability and validity of a short version of the effort-reward imbalance (ERI) questionnaire in a sample of Chinese workers. A community-based survey was conducted in 1,916 subjects aged 30-65 years with paid employment (971 men and 945 women). Acceptable internal consistencies of the three scales, effort, reward and overcommitment, were obtained. Confirmatory factor analysis showed a good model fit of the data with the theoretical structure (goodness-of-fit index = 0.95). Evidence of criterion validity was demonstrated, as all three scales were independently associated with elevated odds ratios of both poor physical and mental health. Based on the findings of our study, this short version of the ERI questionnaire is considered to be a reliable and valid tool for measuring psychosocial work environment in Chinese working populations.

  19. The Parent-Version of the Spence Children's Anxiety Scale (SCAS-P) in Chinese and Italian Community Samples: Validation and Cross-Cultural Comparison.

    PubMed

    Li, Jian-Bin; Delvecchio, Elisa; Di Riso, Daniela; Nie, Yan-Gang; Lis, Adriana

    2016-06-01

    The current study aimed to validate the parent-version of the Spence Children's Anxiety Scale (SCAS-P) among Chinese and Italian community adolescents and to compare adolescents' anxiety symptoms in these two countries. Chinese (N = 456) and Italian (N = 452) adolescents and their parents participated in the study. Results showed that: (1) the six correlated-factor structure was demonstrated and invariant across countries. (2) The reliability of the total scale was good in both samples, whereas reliabilities of subscales were acceptable and moderate in Chinese and Italian samples, respectively. (3) The SCAS-P showed good convergent and divergent validity. (4) Adolescent-parent agreement was from low to medium while mother-father agreement ranged from medium to high. (5) There were cultural and gender differences in levels of parent-report anxiety symptoms. In conclusion, SCAS-P seems to be a promising parent-report instrument to assess Chinese and Italian adolescents' anxiety symptoms.

  20. Development and Validation of a Measure of Quality of Life for the Young Elderly in Sri Lanka

    PubMed Central

    de Silva, Sudirikku Hennadige Padmal; Jayasuriya, Anura Rohan; Rajapaksa, Lalini Chandika; de Silva, Ambepitiyawaduge Pubudu; Barraclough, Simon

    2016-01-01

    Sri Lanka has one of the fastest aging populations in the world. Measurement of quality of life (QoL) in the elderly needs instruments developed that encompass the sociocultural settings. An instrument was developed to measure QoL in the young elderly in Sri Lanka (QLI-YES), using accepted methods to generate and reduce items. The measure was validated using a community sample. Construct, criterion and predictive validity and reliability were tested. A first-order model of 24 items with 6 domains was found to have good fit indices (CMIN/df = 1.567, RMR = 0.05, CFI = 0.95, and RMSEA = 0.053). Both criterion and predictive validity were demonstrated. Good internal consistency reliability (Cronbach’s α = 0.93) was shown. The development of the QLI-YES using a societal perspective relevant to the social and cultural beliefs has resulted in a robust and valid instrument to measure QoL for the young elderly in Sri Lanka. PMID:26712893

  1. Evaluation of the CEAS model for barley yields in North Dakota and Minnesota

    NASA Technical Reports Server (NTRS)

    Barnett, T. L. (Principal Investigator)

    1981-01-01

    The CEAS yield model is based upon multiple regression analysis at the CRD and state levels. For the historical time series, yield is regressed on a set of variables derived from monthly mean temperature and monthly precipitation. Technological trend is represented by piecewise linear and/or quadriatic functions of year. Indicators of yield reliability obtained from a ten-year bootstrap test (1970-79) demonstrated that biases are small and performance as indicated by the root mean square errors are acceptable for intended application, however, model response for individual years particularly unusual years, is not very reliable and shows some large errors. The model is objective, adequate, timely, simple and not costly. It considers scientific knowledge on a broad scale but not in detail, and does not provide a good current measure of modeled yield reliability.

  2. Psychometric Properties of the Persian Version of the Simple Shoulder Test (SST) Questionnaire.

    PubMed

    Ebrahimzadeh, Mohammad H; Vahedi, Ehsan; Baradaran, Aslan; Birjandinejad, Ali; Seyyed-Hoseinian, Seyyed-Hadi; Bagheri, Farshid; Kachooei, Amir Reza

    2016-10-01

    To validate the Persian version of the simple shoulder test in patients with shoulder joint problems. Following Beaton`s guideline, translation and back translation was conducted. We reached to a consensus on the Persian version of SST. To test the face validity in a pilot study, the Persian SST was administered to 20 individuals with shoulder joint conditions. We enrolled 148 consecutive patients with shoulder problem to fill the Persian SST, shoulder specific measure including Oxford shoulder score (OSS) and two general measures including DASH and SF-36. To measure the test-retest reliability, 42 patients were randomly asked to fill the Persian-SST for the second time after one week. Cronbach's alpha coefficient was used to demonstrate internal consistency over the 12 items of Persian-SST. ICC for the total questionnaire was 0.61 showing good and acceptable test-retest reliability. ICC for individual items ranged from 0.32 to 0.79. The total Cronbach's alpha was 0.84 showing good internal consistency over the 12 items of the Persian-SST. Validity testing showed strong correlation between SST and OSS and DASH. The correlation with OSS was positive while with DASH scores was negative. The correlation was also good to strong with all physical and most mental subscales of the SF-36. Correlation coefficient was higher with DASH and OSS in compare to SF-36. Persian version of SST found to be valid and reliable instrument for shoulder joint pain and function assessment in Iranian population.

  3. How reliable and valid is the teacher version of the Strengths and Difficulties Questionnaire in primary school children?

    PubMed

    van den Heuvel, Meta; Jansen, Danielle E M C; Stewart, Roy E; Smits-Engelsman, Bouwien C M; Reijneveld, Sijmen A; Flapper, Boudien C T

    2017-01-01

    The Strengths and Difficulties Questionnaire (SDQ) is validated for parents, but not yet for teachers in a broad age range of children. We conducted a cross-sectional study with 4-10 years old school children to investigate if the SDQ-T can be used instead of the validated but lengthy Teacher's Report Form (TRF) to acquire information about emotional and behavioral problems in the school community. Teachers of 453 children from primary schools were approached. Teachers of 394 children (response rate 86.9%) with a mean age of 7.1 years filled in the SDQ-T (n = 387), the TRF (n = 349) or both (n = 342). We assessed reliability by calculating internal consistency and concurrent validity (using correlation coefficients, sensitivity, specificity) of the SDQ-T compared with the TRF. Internal consistency of the SDQ-T Total Difficulties Score (SDQ-T TDS; Cronbach α = 0.80), hyperactivity/ inattention- (α = 0.86) and prosocial behavior (α = 0.81) was very good. Concurrent validity demonstrated a strong correlation of all subscales of the SDQ-T with the corresponding scale on the TRF (range 0.54-0.73), except for peer problems (0.46). Using a SDQ-T TDS cut-off score > 14, the SDQ-T had a good sensitivity (90%) and specificity (94%). The good reliability, validity and brevity of the SDQ-T make it an easily applicable questionnaire for obtaining information about emotional and behavioral problems from teachers in primary school children.

  4. Application of distributed optical fiber sensing technologies to the monitoring of leakage and abnormal disturbance of oil pipeline

    NASA Astrophysics Data System (ADS)

    Yang, Xiaojun; Zhu, Xiaofei; Deng, Chi; Li, Junyi; Liu, Cheng; Yu, Wenpeng; Luo, Hui

    2017-10-01

    To improve the level of management and monitoring of leakage and abnormal disturbance of long distance oil pipeline, the distributed optical fiber temperature and vibration sensing system is employed to test the feasibility for the healthy monitoring of a domestic oil pipeline. The simulating leakage and abnormal disturbance affairs of oil pipeline are performed in the experiment. It is demonstrated that the leakage and abnormal disturbance affairs of oil pipeline can be monitored and located accurately with the distributed optical fiber sensing system, which exhibits good performance in the sensitivity, reliability, operation and maintenance etc., and shows good market application prospect.

  5. Premonitory urges for tics in adult patients with Tourette syndrome.

    PubMed

    Crossley, Eleanor; Seri, Stefano; Stern, Jeremy S; Robertson, Mary M; Cavanna, Andrea E

    2014-01-01

    Patients with Tourette syndrome (TS) often report characteristic sensory experiences, also called premonitory urges (PUs), which precede tic expression and have high diagnostic relevance. This study investigated the usefulness of a scale developed and validated in children and adolescents-the Premonitory Urge for Tics Scale (PUTS, Woods et al., 2005 [13])-for the assessment of PUs in adult patients with TS. Standard statistical methods were applied to test the psychometric properties of the PUTS in 102 adult TS outpatients recruited from two specialist clinics in the United Kingdom. The PUTS showed good acceptability and endorsement rates, with evenly distributed scores and low floor and ceiling effects. Item-total correlations were moderate to strong; PUTS total scores were significantly correlated with quantitative measures of TS severity. The PUTS showed excellent internal consistency reliability (Cronbach's alpha=0.85) and Spearman's correlations demonstrated satisfactory convergent and discriminant validity. Although originally devised to assess urges to tic in young patients with TS, the PUTS demonstrated good psychometric properties in a large sample of adults recruited at specialist TS clinics. This instrument is therefore recommended for use across the life span as a valid and reliable self-report measure of sensory experiences accompanying tic expression. Copyright © 2013 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  6. The Myotonometer: Not a Valid Measurement Tool for Active Hamstring Musculotendinous Stiffness.

    PubMed

    Pamukoff, Derek N; Bell, Sarah E; Ryan, Eric D; Blackburn, J Troy

    2016-05-01

    Hamstring musculotendinous stiffness (MTS) is associated with lower-extremity injury risk (ie, hamstring strain, anterior cruciate ligament injury) and is commonly assessed using the damped oscillatory technique. However, despite a preponderance of studies that measure MTS reliably in laboratory settings, there are no valid clinical measurement tools. A valid clinical measurement technique is needed to assess MTS and permit identification of individuals at heightened risk of injury and track rehabilitation progress. To determine the validity and reliability of the Myotonometer for measuring active hamstring MTS. Descriptive laboratory study. Laboratory. 33 healthy participants (15 men, age 21.33 ± 2.94 y, height 172.03 ± 16.36 cm, mass 74.21 ± 16.36 kg). Hamstring MTS was assessed using the damped oscillatory technique and the Myotonometer. Intraclass correlations were used to determine the intrasession, intersession, and interrater reliability of the Myotonometer. Criterion validity was assessed via Pearson product-moment correlation between MTS measures obtained from the Myotonometer and from the damped oscillatory technique. The Myotonometer demonstrated good intrasession (ICC3,1 = .807) and interrater reliability (ICC2,k = .830) and moderate intersession reliability (ICC2,k = .693). However, it did not provide a valid measurement of MTS compared with the damped oscillatory technique (r = .346, P = .061). The Myotonometer does not provide a valid measure of active hamstring MTS. Although the Myotonometer does not measure active MTS, it possesses good reliability and portability and could be used clinically to measure tissue compliance, muscle tone, or spasticity associated with multiple musculoskeletal disorders. Future research should focus on portable and clinically applicable tools to measure active hamstring MTS in efforts to prevent and monitor injuries.

  7. Development of the adult PedsQL™ neurofibromatosis type 1 module: initial feasibility, reliability and validity.

    PubMed

    Nutakki, Kavitha; Hingtgen, Cynthia M; Monahan, Patrick; Varni, James W; Swigonski, Nancy L

    2013-02-21

    Neurofibromatosis type 1 (NF1) is a common autosomal dominant genetic disorder with significant impact on health-related quality of life (HRQOL). Research in understanding the pathogenetic mechanisms of neurofibroma development has led to the use of new clinical trials for the treatment of NF1. One of the most important outcomes of a trial is improvement in quality of life, however, no condition specific HRQOL instrument for NF1 exists. The objective of this study was to develop an NF1 HRQOL instrument as a module of PedsQL™ and to test for its initial feasibility, internal consistency reliability and validity in adults with NF1. The NF1 specific HRQOL instrument was developed using a standard method of PedsQL™ module development - literature review, focus group/semi-structured interviews, cognitive interviews and experts' review of initial draft, pilot testing and field testing. Field testing involved 134 adults with NF1. Feasibility was measured by the percentage of missing responses, internal consistency reliability was measured with Cronbach's alpha and validity was measured by the known-groups method. Feasibility, measured by the percentage of missing responses was 4.8% for all subscales on the adult version of the NF1-specific instrument. Internal consistency reliability for the Total Score (alpha =0.97) and subscale reliabilities ranging from 0.72 to 0.96 were acceptable for group comparisons. The PedsQL™ NF1 module distinguished between NF1 adults with excellent to very good, good, and fair to poor health status. The results demonstrate the initial feasibility, reliability and validity of the PedsQL™ NF1 module in adult patients. The PedsQL™ NF1 Module can be used to understand the multidimensional nature of NF1 on the HRQOL patients with this disorder.

  8. The reliability and validity of the Turkish version of Fullerton Advanced Balance (FAB-T) scale.

    PubMed

    Iyigun, Gozde; Kirmizigil, Berkiye; Angin, Ender; Oksuz, Sevim; Can, Filiz; Eker, Levent; Rose, Debra J

    2018-06-04

    The aim of this study was to evaluate the reliability and validity of the Turkish version of the FAB(FAB-T) scale in the older Turkish adults. The reliability and validity of the scale was tested on 200 community-dwelling older adults. FAB-T scale was scored by different physiotherapists on different days to evaluate inter-rater and intrarater reliability. The Berg Balance Scale (BBS) was used for the evaluation of convergent validity, and the content validity of the FAB-T scale was investigated. The FAB-T scale showed very high inter- and intra-rater reliability. For inter-rater agreement, on the individual test items and total score ICC values were 0.92 (95 %CI; 0.90-0.94) and 0.96 (95% CI; 0.95-0.97) respectively. The intra-rater agreement, on the individual test items and total score ICC values were 0.93 (95 %CI; 0.91- 0.95) and 0.96 (95% CI; 0.95- 0.97) respectively. There was a good agreement between the FAB-T and BBS scales. A high correlation was found between the BBS and FAB-T scales [rho = 0.70 (%95 CI; 0.62-0.76)] indicating good convergent validity. Considering the content validity of the FAB-T scale, no floor (floor score: 0%) or ceiling (ceiling score: 6.5%) effect was detected. The FAB-T scale was successfully translated from the original English version (FAB) and demonstrated strong psychometric features. It was found that the FAB-T scale has very high inter-rater and intra-rater reliability. Considering the convergent validity, the scale has high correlation with the BBS. The FAB-T has no floor and ceiling effect. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. RELIABILITY AND VALIDITY OF A BIOMECHANICALLY BASED ANALYSIS METHOD FOR THE TENNIS SERVE

    PubMed Central

    Kibler, W. Ben; Lamborn, Leah; Smith, Belinda J.; English, Tony; Jacobs, Cale; Uhl, Tim L.

    2017-01-01

    Background An observational tennis serve analysis (OTSA) tool was developed using previously established body positions from three-dimensional kinematic motion analysis studies. These positions, defined as nodes, have been associated with efficient force production and minimal joint loading. However, the tool has yet to be examined scientifically. Purpose The primary purpose of this investigation was to determine the inter-observer reliability for each node between two health care professionals (HCPs) that developed the OTSA, and secondarily to investigate the validity of the OTSA. Methods Two separate studies were performed to meet these objectives. An inter-observer reliability study preceded the validity study by examining 28 videos of players serving. Two HCPs graded each video and scored the presence or absence of obtaining each node. Discriminant validity was determined in 33 tennis players using video taped records of three first serves. Serve mechanics were graded using the OSTA and categorized players into those with good ( ≥ 5) and poor ( ≤ 4) mechanics. Participants performed a series of field tests to evaluate trunk flexibility, lower extremity and trunk power, and dynamic balance. Results The group with good mechanics demonstrated greater backward trunk flexibility (p=0.02), greater rotational power (p=0.02), and higher single leg countermovement jump (p=0.05). Reliability of the OTSA ranged from K = 0.36-1.0, with the majority of all the nodes displaying substantial reliability (K>0.61). Conclusion This study provides HCPs with a valid and reliable field tool used to assess serve mechanics. Physical characteristics of trunk mobility and power appear to discriminate serve mechanics between players. Future intervention studies are needed to determine if improvement in physical function contribute to improved serve mechanics. Level of Evidence 3 PMID:28593098

  10. Development and validation of a fatigue assessment scale for U.S. construction workers.

    PubMed

    Zhang, Mingzong; Sparer, Emily H; Murphy, Lauren A; Dennerlein, Jack T; Fang, Dongping; Katz, Jeffrey N; Caban-Martinez, Alberto J

    2015-02-01

    To develop a fatigue assessment scale and test its reliability and validity for commercial construction workers. Using a two-phased approach, we first identified items (first phase) for the development of a Fatigue Assessment Scale for Construction Workers (FASCW) through review of existing scales in the scientific literature, key informant interviews (n = 11) and focus groups (three groups with six workers each) with construction workers. The second phase included assessment for the reliability, validity, and sensitivity of the new scale using a repeated-measures study design with a convenience sample of construction workers (n = 144). Phase one resulted in a 16-item preliminary scale that after factor analysis yielded a final 10-item scale with two sub-scales ("Lethargy" and "Bodily Ailment"). During phase two, the FASCW and its subscales demonstrated satisfactory internal consistency (alpha coefficients were FASCW [0.91], Lethargy [0.86] and Bodily Ailment [0.84]) and acceptable test-retest reliability (Pearson Correlations Coefficients: 0.59-0.68; Intraclass Correlation Coefficients: 0.74-0.80). Correlation analysis substantiated concurrent and convergent validity. A discriminant analysis demonstrated that the FASCW differentiated between groups with arthritis status and different work hours. The 10-item FASCW with good reliability and validity is an effective tool for assessing the severity of fatigue among construction workers. © 2015 Wiley Periodicals, Inc.

  11. Validating survey measurement scales for AIDS-related knowledge and stigma among construction workers in South Africa.

    PubMed

    Bowen, Paul; Govender, Rajen; Edwards, Peter

    2016-01-23

    Construction workers in South Africa are regarded as a high-risk group in the context of HIV/AIDS. HIV testing is pivotal to controlling HIV transmission and providing palliative care and AIDS-related knowledge and stigma are key issues in addressing the likelihood of testing behaviour. In exploring these issues, various studies have employed an 11-item AIDS-related knowledge scale (Kalichman and Simbayi, AIDS Care 16:572-580, 2004) and a 9-item stigma scale (Kalichman et al., AIDS Behav 9:135-143, 2005), but little evidence exists confirming the psychometric properties of these scales. Using survey data from 512 construction workers in the Western Cape, South Africa, this research examines the validity and reliability of the two scales through exploratory and confirmatory factor analysis and internal consistency tests. From confirmatory factor analysis, a revised 10-item knowledge scale was developed (χ2 /df ratio = 1.675, CFI = 0.982, RMSEA = 0.038, and Hoelter (95 %) = 393). A revised 8-item stigma scale was also developed (χ2 /df ratio = 1.929, CFI = 0.974, RMSEA = 0.045, and Hoelter (95 %) = 380). Both revised scales demonstrated good model fit and all factor loadings were significant (p < 0.01). Reliability analysis demonstrated excellent to good internal consistency, with alpha values of 0.80 and 0.74, respectively. Both revised scales also demonstrated satisfactory convergent and divergent validity. Limitations of the original survey from which the data was obtained include the failure to properly account for respondent selection of language for completion of the survey, use of ethnicity as a proxy for identifying the native language of participants, the limited geographical area from which the survey data was collected, and the limitations associated with the convenience sample. A limitation of the validation study was the lack of available data for a more robust examination of reliability beyond internal consistency, such as test-retest reliability. The revised knowledge and stigma scales offered here hold considerable promise as measures of AIDS-related knowledge and stigma among South African construction workers.

  12. Reliability of the test of gross motor development second edition (TGMD-2) for Kindergarten children in Myanmar

    PubMed Central

    Aye, Thanda; Oo, Khin Saw; Khin, Myo Thuzar; Kuramoto-Ahuja, Tsugumi; Maruyama, Hitoshi

    2017-01-01

    [Purpose] The purpose of this study was to investigate reliability of the test of gross motor development second edition (TGMD-2) for Kindergarten children in Myanmar. [Subjects and Methods] Fifty healthy Kindergarten children (23 males, 27 females) whose parents/guardians had given written consent were participated. The subjects were explained and demonstrated all 12 gross motor skills of TGMD-2 before the assessment. Each subject individually performed two trials for each gross motor skill and the performance was video recorded. Three raters separately watched the video recordings and rated for inter-rater reliability. The second assessment was done one month later with 25 out of 50 subjects for test-rest reliability. The video recordings of 12 subjects were randomly selected from the first 50 recordings for intra-rater reliability six weeks after the first assessment. The agreement on the locomotor and object control raw scores and the gross motor quotient (GMQ) were calculated. [Results] The findings of all the reliability coefficients for the locomotor and object control raw scores and the GMQ were interpreted as good and excellent reliability. [Conclusion] The results represented that TGMD-2 is a highly reliable and appropriate assessment tool for assessing gross motor skill development of Kindergarten children in Myanmar. PMID:29184278

  13. Reliability of the test of gross motor development second edition (TGMD-2) for Kindergarten children in Myanmar.

    PubMed

    Aye, Thanda; Oo, Khin Saw; Khin, Myo Thuzar; Kuramoto-Ahuja, Tsugumi; Maruyama, Hitoshi

    2017-10-01

    [Purpose] The purpose of this study was to investigate reliability of the test of gross motor development second edition (TGMD-2) for Kindergarten children in Myanmar. [Subjects and Methods] Fifty healthy Kindergarten children (23 males, 27 females) whose parents/guardians had given written consent were participated. The subjects were explained and demonstrated all 12 gross motor skills of TGMD-2 before the assessment. Each subject individually performed two trials for each gross motor skill and the performance was video recorded. Three raters separately watched the video recordings and rated for inter-rater reliability. The second assessment was done one month later with 25 out of 50 subjects for test-rest reliability. The video recordings of 12 subjects were randomly selected from the first 50 recordings for intra-rater reliability six weeks after the first assessment. The agreement on the locomotor and object control raw scores and the gross motor quotient (GMQ) were calculated. [Results] The findings of all the reliability coefficients for the locomotor and object control raw scores and the GMQ were interpreted as good and excellent reliability. [Conclusion] The results represented that TGMD-2 is a highly reliable and appropriate assessment tool for assessing gross motor skill development of Kindergarten children in Myanmar.

  14. Development and validation of a patient-reported outcome measure in vitiligo: The Self Assessment Vitiligo Extent Score (SA-VES).

    PubMed

    van Geel, Nanja; Lommerts, Janny E; Bekkenk, Marcel W; Prinsen, Cecilia A C; Eleftheriadou, Viktoria; Taieb, Alain; Picardo, Mauro; Ezzedine, Khaled; Wolkerstorfer, Albert; Speeckaert, Reinhart

    2017-03-01

    The Vitiligo Extent Score (VES) has recently been introduced as a physicians' score for the clinical assessment of the extent of vitiligo, but a good patient self-assessment score is lacking. The objective is to develop and validate a simplified version of the VES as a patient-reported outcome measure (PROM). After extensive pilot testing, patients were asked to score their vitiligo extent twice with an interval of 2 weeks using the Self Assessment Vitiligo Extent Score (SA-VES). The scores were compared with the physicians' evaluation (VES). The SA-VES demonstrated very good test-retest reliability (intraclass correlation = 0.948, 95% confidence interval [CI]: 0.911-0.970) that was not affected by age, skin type, or vitiligo distribution pattern. According to patients, this evaluation method was easy to use (22% very easy; 49% easy; 29% normal) and required <5 minutes in the majority of patients (73%, <5 minutes; 24%, 5-10 minutes; 2%, 10-15 minutes). Comparison of the SA-VES and the VES demonstrated excellent correlation (r = 0.986, P <.001). Few patients had a dark skin type. The results demonstrate excellent reliability of the SA-VES and excellent correlation with its investigator-reported counterpart (VES). This patient-oriented evaluation method provides a useful tool for the assessment of vitiligo extent. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Psychometric Properties of a Standardized Observation Protocol to Quantify Pediatric Physical Therapy Actions.

    PubMed

    Sonderer, Patrizia; Akhbari Ziegler, Schirin; Gressbach Oertle, Barbara; Meichtry, André; Hadders-Algra, Mijna

    2017-07-01

    Pediatric physical therapy (PPT) is characterized by heterogeneity. This blurs the evaluation of effective components of PPT. The Groningen Observation Protocol (GOP) was developed to quantify contents of PPT. This study assesses the reliability and completeness of the GOP. Sixty infant PPT sessions were video-taped. Two random samples of 10 videos were used to determine interrater and intrarater reliability using interclass correlation coefficients (ICCs) with 95% confidence intervals. Completeness of GOP 2.0 was based on 60 videos. Interrater reliability of quantifying PPT actions was excellent (ICC, 0.75-1.0) in 71% and sufficient to good (ICC, 0.4-0.74) in 24% of PPT actions. Intrarater reliability was excellent in 94% and sufficient to good in 6% of PPT actions. Completeness was good for greater than 90% of PPT actions. GOP 2.0 has good reliability and completeness. After appropriate training, it is a useful tool to quantify PPT for children with developmental disorders.

  16. Assessing Psychodynamic Conflict.

    PubMed

    Simmonds, Joshua; Constantinides, Prometheas; Perry, J Christopher; Drapeau, Martin; Sheptycki, Amanda R

    2015-09-01

    Psychodynamic psychotherapies suggest that symptomatic relief is provided, in part, with the resolution of psychic conflicts. Clinical researchers have used innovative methods to investigate such phenomenon. This article aims to review the literature on quantitative psychodynamic conflict rating scales. An electronic search of the literature was conducted to retrieve quantitative observer-rated scales used to assess conflict noting each measure's theoretical model, information source, and training and clinical experience required. Scales were also examined for levels of reliability and validity. Five quantitative observer-rated conflict scales were identified. Reliability varied from poor to excellent with each measure demonstrating good validity. However a small number of studies and limited links to current conflict theory suggest further clinical research is needed.

  17. Assessing Perceptions AbouT Hazardous Substances (PATHS): The PATHS questionnaire

    PubMed Central

    Amlôt, Richard; Page, Lisa; Pearce, Julia; Wessely, Simon

    2013-01-01

    How people perceive the nature of a hazardous substance may determine how they respond when potentially exposed to it. We tested a new Perceptions AbouT Hazardous Substances (PATHS) questionnaire. In Study 1 (N = 21), we assessed the face validity of items concerning perceptions about eight properties of a hazardous substance. In Study 2 (N = 2030), we tested the factor structure, reliability and validity of the PATHS questionnaire across four qualitatively different substances. In Study 3 (N = 760), we tested the impact of information provision on Perceptions AbouT Hazardous Substances scores. Our results showed that our eight measures demonstrated good reliability and validity when used for non-contagious hazards. PMID:23104995

  18. Psychometric Properties of the Adolescent Reinforcement Survey Schedule – Alcohol Use Version with College Student Drinkers

    PubMed Central

    Hallgren, Kevin A.; Greenfield, Brenna L.; Ladd, Benjamin O.

    2016-01-01

    Background Behavioral economic theories of drinking posit that the reinforcing value of engaging in activities with versus without alcohol influences drinking behavior. Measures of the reinforcement value of drugs and alcohol have been used in previous research, but little work has examined the psychometric properties of these measures. Objectives The present study aims to evaluate the factor structure, test-retest reliability, and concurrent validity of an alcohol-only version of the Adolescent Reinforcement Survey Schedule (ARSS-AUV). Methods A sample of 157 college student drinkers completed the ARSS-AUV at two time points 2–3 days apart. Test-retest reliability, hierarchical factor analysis, and correlations with other drinking measures were examined. Results Single, unidimensional general factors accounted for a majority of the variance in alcohol and alcohol-free reinforcement items. Residual factors emerged that typically represented alcohol or alcohol-free reinforcement while doing activities with friends, romantic or sexual partners, and family members. Individual ARSS-AUV items had fair-to-good test-retest reliability, while general and residual factors had excellent test-retest reliability. General alcohol reinforcement and alcohol reinforcement from friends and romantic partners were positively correlated with past-year alcohol consumption, heaviest drinking episode, and alcohol-related negative consequences. Alcohol-free reinforcement indices were unrelated to alcohol use or consequences. Conclusions/Importance The ARSS-AUV appears to demonstrate good reliability and mixed concurrent validity among college student drinkers. The instrument may provide useful information about alcohol reinforcement from various activities and people and could provide clinically-relevant information for prevention and treatment programs. PMID:27096713

  19. Psychometric Properties of the Adolescent Reinforcement Survey Schedule-Alcohol Use Version with College Student Drinkers.

    PubMed

    Hallgren, Kevin A; Greenfield, Brenna L; Ladd, Benjamin O

    2016-06-06

    Behavioral economic theories of drinking posit that the reinforcing value of engaging in activities with versus without alcohol influences drinking behavior. Measures of the reinforcement value of drugs and alcohol have been used in previous research, but little work has examined the psychometric properties of these measures. The present study aims to evaluate the factor structure, test-retest reliability, and concurrent validity of an alcohol-only version of the Adolescent Reinforcement Survey Schedule (ARSS-AUV). A sample of 157 college student drinkers completed the ARSS-AUV at two time points 2-3 days apart. Test-retest reliability, hierarchical factor analysis, and correlations with other drinking measures were examined. Single, unidimensional general factors accounted for a majority of the variance in alcohol and alcohol-free reinforcement items. Residual factors emerged that typically represented alcohol or alcohol-free reinforcement while doing activities with friends, romantic or sexual partners, and family members. Individual ARSS-AUV items had fair-to-good test-retest reliability, while general and residual factors had excellent test-retest reliability. General alcohol reinforcement and alcohol reinforcement from friends and romantic partners were positively correlated with past-year alcohol consumption, heaviest drinking episode, and alcohol-related negative consequences. Alcohol-free reinforcement indices were unrelated to alcohol use or consequences. The ARSS-AUV appears to demonstrate good reliability and mixed concurrent validity among college student drinkers. The instrument may provide useful information about alcohol reinforcement from various activities and people and could provide clinically-relevant information for prevention and treatment programs.

  20. Reliability, factor structure, and validity of the German version of the Trauma Symptom Checklist for Children in a sample of adolescents

    PubMed Central

    Matulis, Simone; Loos, Laura; Langguth, Nadine; Schreiber, Franziska; Gutermann, Jana; Gawrilow, Caterina; Steil, Regina

    2015-01-01

    Background The Trauma Symptom Checklist for Children (TSC-C) is the most widely used self-report scale to assess trauma-related symptoms in children and adolescents on six clinical scales. The purpose of the present study was to develop a German version of the TSC-C and to investigate its psychometric properties, such as factor structure, reliability, and validity, in a sample of German adolescents. Method A normative sample of N=583 and a clinical sample of N=41 adolescents with a history of physical or sexual abuse aged between 13 and 21 years participated in the study. Results The Confirmatory Factor Analysis on the six-factor model (anger, anxiety, depression, dissociation, posttraumatic stress, and sexual concerns with the subdimensions preoccupation and distress) revealed acceptable to good fit statistics in the normative sample. One item had to be excluded from the German version of the TSC-C because the factor loading was too low. All clinical scales presented acceptable to good reliability, with Cronbach's α's ranging from .80 to .86 in the normative sample and from .72 to .87 in the clinical sample. Concurrent validity was also demonstrated by the high correlations between the TSC-C scales and instruments measuring similar psychopathology. TSC-C scores reliably differentiated between adolescents with trauma history and those without trauma history, indicating discriminative validity. Conclusions In conclusion, the German version of the TSC-C is a reliable and valid instrument for assessing trauma-related symptoms on six different scales in adolescents aged between 13 and 21 years. PMID:26498182

  1. Reliability, factor structure, and validity of the German version of the Trauma Symptom Checklist for Children in a sample of adolescents.

    PubMed

    Matulis, Simone; Loos, Laura; Langguth, Nadine; Schreiber, Franziska; Gutermann, Jana; Gawrilow, Caterina; Steil, Regina

    2015-01-01

    The Trauma Symptom Checklist for Children (TSC-C) is the most widely used self-report scale to assess trauma-related symptoms in children and adolescents on six clinical scales. The purpose of the present study was to develop a German version of the TSC-C and to investigate its psychometric properties, such as factor structure, reliability, and validity, in a sample of German adolescents. A normative sample of N=583 and a clinical sample of N=41 adolescents with a history of physical or sexual abuse aged between 13 and 21 years participated in the study. The Confirmatory Factor Analysis on the six-factor model (anger, anxiety, depression, dissociation, posttraumatic stress, and sexual concerns with the subdimensions preoccupation and distress) revealed acceptable to good fit statistics in the normative sample. One item had to be excluded from the German version of the TSC-C because the factor loading was too low. All clinical scales presented acceptable to good reliability, with Cronbach's α's ranging from .80 to .86 in the normative sample and from .72 to .87 in the clinical sample. Concurrent validity was also demonstrated by the high correlations between the TSC-C scales and instruments measuring similar psychopathology. TSC-C scores reliably differentiated between adolescents with trauma history and those without trauma history, indicating discriminative validity. In conclusion, the German version of the TSC-C is a reliable and valid instrument for assessing trauma-related symptoms on six different scales in adolescents aged between 13 and 21 years.

  2. Development of the Persian version of the Vertigo Symptom Scale: Validity and reliability

    PubMed Central

    Kamalvand, Atefeh; Ghahraman, Mansoureh Adel; Jalaie, Shohreh

    2017-01-01

    Background: Vertigo Symptom Scale (VSS) is a proper instrument for assessing the patient status, clarifying the symptoms, and examining the relative impact of the vertigo and anxiety on reported handicap. Our aim is the translation and cross-cultural adaptation of the VSS into Persian language (VSS-P) and investigating its validity and reliability in patients with peripheral vestibular disorders. Materials and Methods: VSS was translated into Persian. Cross-cultural adaptation was carried out on 101 patients with peripheral vestibular disorders and 34 participants with no history of vertigo. They completed the Persian versions of VSS, dizziness handicap inventory (DHI), and Beck anxiety inventory (BAI). Internal, discriminant, and convergent validities, internal consistency, and test-retest reliability were determined. Results: The VSS-P showed good face validity. Internal validity was confirmed and demonstrated the presence of two vertigo (VSS-VER) and autonomic-anxiety (VSS-AA) subscales. Significant difference between the median scores for patient and healthy groups was reported in discriminate validity (P <0.001). Convergent validity revealed high correlation between both BAI and DHI with VSS-P. There was a high test-retest reliability; with intraclass correlation coefficient of 0.89, 0.86, and 0.91 for VSS-AA, VER, and VSS-P, respectively. The internal consistency was good with Cronbach's alpha 0.90 for VER subscale, 0.86 for VSS-AA subscale, and 0.92 for the overall VSS-P. Conclusion: The Persian version of the VSS could be used clinically as a valid and reliable tool. Thus, it is a key instrument to focus on the symptoms associated with dizziness. PMID:28616045

  3. Development of the Persian version of the Vertigo Symptom Scale: Validity and reliability.

    PubMed

    Kamalvand, Atefeh; Ghahraman, Mansoureh Adel; Jalaie, Shohreh

    2017-01-01

    Vertigo Symptom Scale (VSS) is a proper instrument for assessing the patient status, clarifying the symptoms, and examining the relative impact of the vertigo and anxiety on reported handicap. Our aim is the translation and cross-cultural adaptation of the VSS into Persian language (VSS-P) and investigating its validity and reliability in patients with peripheral vestibular disorders. VSS was translated into Persian. Cross-cultural adaptation was carried out on 101 patients with peripheral vestibular disorders and 34 participants with no history of vertigo. They completed the Persian versions of VSS, dizziness handicap inventory (DHI), and Beck anxiety inventory (BAI). Internal, discriminant, and convergent validities, internal consistency, and test-retest reliability were determined. The VSS-P showed good face validity. Internal validity was confirmed and demonstrated the presence of two vertigo (VSS-VER) and autonomic-anxiety (VSS-AA) subscales. Significant difference between the median scores for patient and healthy groups was reported in discriminate validity ( P <0.001). Convergent validity revealed high correlation between both BAI and DHI with VSS-P. There was a high test-retest reliability; with intraclass correlation coefficient of 0.89, 0.86, and 0.91 for VSS-AA, VER, and VSS-P, respectively. The internal consistency was good with Cronbach's alpha 0.90 for VER subscale, 0.86 for VSS-AA subscale, and 0.92 for the overall VSS-P. The Persian version of the VSS could be used clinically as a valid and reliable tool. Thus, it is a key instrument to focus on the symptoms associated with dizziness.

  4. The live donor assessment tool: a psychosocial assessment tool for live organ donors.

    PubMed

    Iacoviello, Brian M; Shenoy, Akhil; Braoude, Jenna; Jennings, Tiane; Vaidya, Swapna; Brouwer, Julianna; Haydel, Brandy; Arroyo, Hansel; Thakur, Devendra; Leinwand, Joseph; Rudow, Dianne LaPointe

    2015-01-01

    Psychosocial evaluation is an important part of the live organ donor evaluation process, yet it is not standardized across institutions, and although tools exist for the psychosocial evaluation of organ recipients, none exist to assess donors. We set out to develop a semistructured psychosocial evaluation tool (the Live Donor Assessment Tool, LDAT) to assess potential live organ donors and to conduct preliminary analyses of the tool's reliability and validity. Review of the literature on the psychosocial variables associated with treatment adherence, quality of life, live organ donation outcome, and resilience, as well as review of the procedures for psychosocial evaluation at our center and other centers around the country, identified 9 domains to address; these domains were distilled into several items each, in collaboration with colleagues at transplant centers across the country, for a total of 29 items. Four raters were trained to use the LDAT, and they retrospectively scored 99 psychosocial evaluations conducted on live organ donor candidates. Reliability of the LDAT was assessed by calculating the internal consistency of the items in the scale and interrater reliability between raters; validity was estimated by comparing LDAT scores between those with a "positive" evaluation outcome and "negative" outcome. The LDAT was found to have good internal consistency, inter-rater reliability, and showed signs of validity: LDAT scores differentiated the positive vs. negative outcome groups. The LDAT demonstrated good reliability and validity, but future research on the LDAT and the ability to implement the LDAT prospectively is warranted. Copyright © 2015 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  5. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review.

    PubMed

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans; Søgaard, Karen

    2014-10-01

    The aims were to compile a schematic overview of clinical scapular assessment methods and critically appraise the methodological quality of the involved studies. A systematic, computer-assisted literature search using Medline, CINAHL, SportDiscus and EMBASE was performed from inception to October 2013. Reference lists in articles were also screened for publications. From 50 articles, 54 method names were identified and categorized into three groups: (1) Static positioning assessment (n = 19); (2) Semi-dynamic (n = 13); and (3) Dynamic functional assessment (n = 22). Fifteen studies were excluded for evaluation due to no/few clinimetric results, leaving 35 studies for evaluation. Graded according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN checklist), the methodological quality in the reliability and validity domains was "fair" (57%) to "poor" (43%), with only one study rated as "good". The reliability domain was most often investigated. Few of the assessment methods in the included studies that had "fair" or "good" measurement property ratings demonstrated acceptable results for both reliability and validity. We found a substantially larger number of clinical scapular assessment methods than previously reported. Using the COSMIN checklist the methodological quality of the included measurement properties in the reliability and validity domains were in general "fair" to "poor". None were examined for all three domains: (1) reliability; (2) validity; and (3) responsiveness. Observational evaluation systems and assessment of scapular upward rotation seem suitably evidence-based for clinical use. Future studies should test and improve the clinimetric properties, and especially diagnostic accuracy and responsiveness, to increase utility for clinical practice.

  6. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    PubMed

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability. (c) 2015 APA, all rights reserved).

  7. Reliability, Validity, and Factor Structure of the Current Assessment Practice Evaluation-Revised (CAPER) in a National Sample.

    PubMed

    Lyon, Aaron R; Pullmann, Michael D; Dorsey, Shannon; Martin, Prerna; Grigore, Alexandra A; Becker, Emily M; Jensen-Doss, Amanda

    2018-05-11

    Measurement-based care (MBC) is an increasingly popular, evidence-based practice, but there are no tools with established psychometrics to evaluate clinician use of MBC practices in mental health service delivery. The current study evaluated the reliability, validity, and factor structure of scores generated from a brief, standardized tool to measure MBC practices, the Current Assessment Practice Evaluation-Revised (CAPER). Survey data from a national sample of 479 mental health clinicians were used to conduct exploratory and confirmatory factor analyses, as well as reliability and validity analyses (e.g., relationships between CAPER subscales and clinician MBC attitudes). Analyses revealed competing two- and three-factor models. Regardless of the model used, scores from CAPER subscales demonstrated good reliability and convergent and divergent validity with MBC attitudes in the expected directions. The CAPER appears to be a psychometrically sound tool for assessing clinician MBC practices. Future directions for development and application of the tool are discussed.

  8. Reliability of an experimental method to analyse the impact point on a golf ball during putting.

    PubMed

    Richardson, Ashley K; Mitchell, Andrew C S; Hughes, Gerwyn

    2015-06-01

    This study aimed to examine the reliability of an experimental method identifying the location of the impact point on a golf ball during putting. Forty trials were completed using a mechanical putting robot set to reproduce a putt of 3.2 m, with four different putter-ball combinations. After locating the centre of the dimple pattern (centroid) the following variables were tested; distance of the impact point from the centroid, angle of the impact point from the centroid and distance of the impact point from the centroid derived from the X, Y coordinates. Good to excellent reliability was demonstrated in all impact variables reflected in very strong relative (ICC = 0.98-1.00) and absolute reliability (SEM% = 0.9-4.3%). The highest SEM% observed was 7% for the angle of the impact point from the centroid. In conclusion, the experimental method was shown to be reliable at locating the centroid location of a golf ball, therefore allowing for the identification of the point of impact with the putter head and is suitable for use in subsequent studies.

  9. The Worksite Health Promotion Capacity Instrument (WHPCI): development, validation and approaches for determining companies' levels of health promotion capacity.

    PubMed

    Jung, Julia; Nitzsche, Anika; Neumann, Melanie; Wirtz, Markus; Kowalski, Christoph; Wasem, Jürgen; Stieler-Lorenz, Brigitte; Pfaff, Holger

    2010-09-13

    The Worksite Health Promotion Capacity Instrument (WHPCI) was developed to assess two key factors for effective worksite health promotion: collective willingness and the systematic implementation of health promotion activities in companies. This study evaluates the diagnostic qualities of the WHPCI based on its subscales Health Promotion Willingness and Health Promotion Management, which can be used to place companies into four different categories based on their level of health promotion capacity. Psychometric evaluation was conducted using exploratory factor and reliability analyses with data taken from a random sample of managers from n = 522 German information and communication technology (ICT) companies. Receiver operating characteristic (ROC) analyses were conducted to determine further diagnostic qualities of the instrument and to establish the cut-off scores used to determine each company's level of health promotion capacity. The instrument's subscales, Health Promotion Willingness and Health Promotion Management, are based on one-dimensional constructs, each with very good reliability (Cronbach's alpha = 0.83/0.91). ROC analyses demonstrated satisfactory diagnostic accuracy with an area under the curve (AUC) of 0.76 (SE = 0.021; 95% CI 0.72-0.80) for the Health Promotion Willingness scale and 0.81 (SE = 0.021; 95% CI 0.77-0.86) for the Health Promotion Management scale. A cut-off score with good sensitivity (71%/76%) and specificity (69%/75%) was determined for each scale. Both scales were found to have good predictive power and exhibited good efficiency. Our findings indicate preliminary evidence for the validity and reliability of both subscales of the WHPCI. The goodness of each cut-off score suggests that the scales are appropriate for determining companies' levels of health promotion capacity. Support in implementing (systematic) worksite health promotion can then be tailored to each company's needs based on their current capacity level.

  10. A Comparison of Reliability and Construct Validity between the Original and Revised Versions of the Rosenberg Self-Esteem Scale

    PubMed Central

    Nahathai, Wongpakaran

    2012-01-01

    Objective The Rosenberg Self-Esteem Scale (RSES) is a widely used instrument that has been tested for reliability and validity in many settings; however, some negative-worded items appear to have caused it to reveal low reliability in a number of studies. In this study, we revised one negative item that had previously (from the previous studies) produced the worst outcome in terms of the structure of the scale, then re-analyzed the new version for its reliability and construct validity, comparing it to the original version with respect to fit indices. Methods In total, 851 students from Chiang Mai University (mean age: 19.51±1.7, 57% of whom were female), participated in this study. Of these, 664 students completed the Thai version of the original RSES - containing five positively worded and five negatively worded items, while 187 students used the revised version containing six positively worded and four negatively worded items. Confirmatory factor analysis was applied, using a uni-dimensional model with method effects and a correlated uniqueness approach. Results The revised version showed the same level of reliability (good) as the original, but yielded a better model fit. The revised RSES demonstrated excellent fit statistics, with χ2=29.19 (df=19, n=187, p=0.063), GFI=0.970, TFI=0.969, NFI=0.964, CFI=0.987, SRMR=0.040 and RMSEA=0.054. Conclusion The revised version of the Thai RSES demonstrated an equivalent level of reliability but a better construct validity when compared to the original. PMID:22396685

  11. A comparison of reliability and construct validity between the original and revised versions of the Rosenberg Self-Esteem Scale.

    PubMed

    Wongpakaran, Tinakon; Tinakon, Wongpakaran; Wongpakaran, Nahathai; Nahathai, Wongpakaran

    2012-03-01

    The Rosenberg Self-Esteem Scale (RSES) is a widely used instrument that has been tested for reliability and validity in many settings; however, some negative-worded items appear to have caused it to reveal low reliability in a number of studies. In this study, we revised one negative item that had previously (from the previous studies) produced the worst outcome in terms of the structure of the scale, then re-analyzed the new version for its reliability and construct validity, comparing it to the original version with respect to fit indices. In total, 851 students from Chiang Mai University (mean age: 19.51±1.7, 57% of whom were female), participated in this study. Of these, 664 students completed the Thai version of the original RSES - containing five positively worded and five negatively worded items, while 187 students used the revised version containing six positively worded and four negatively worded items. Confirmatory factor analysis was applied, using a uni-dimensional model with method effects and a correlated uniqueness approach. The revised version showed the same level of reliability (good) as the original, but yielded a better model fit. The revised RSES demonstrated excellent fit statistics, with χ²=29.19 (df=19, n=187, p=0.063), GFI=0.970, TFI=0.969, NFI=0.964, CFI=0.987, SRMR=0.040 and RMSEA=0.054. The revised version of the Thai RSES demonstrated an equivalent level of reliability but a better construct validity when compared to the original.

  12. Translation, cultural adaptation, and validation of the Sleep Apnea Quality of Life Index (SAQLI) in Persian-speaking patients with obstructive sleep apnea.

    PubMed

    Rahavi-Ezabadi, Sara; Amali, Amin; Sadeghniiat-Haghighi, Khosro; Montazeri, Ali; Nedjat, Saharnaz

    2016-05-01

    The aim of this study was the translation, cross-cultural adaptation, and validation of the Sleep Apnea Quality of Life Index (SAQLI) in Persian-speaking patients with obstructive sleep apnea (OSA). Ninety-six patients with OSA completed a series of questionnaires including SAQLI, Epworth Sleepiness Scale (ESS),10-item Functional Outcomes of Sleep Questionnaire (FOSQ-10), and Medical Outcome Survey Short form 12 (SF-12) for assessment of reliability, validity, and responsiveness of Persian version of SAQLI. The Persian version of SAQLI had a very good internal consistency and also demonstrated good test-retest reliability. Concurrent validity was confirmed by significant correlations with ESS, FOSQ-10 and SF-12 subscale scores. Comparison of SAQLI scores in groups of patients categorized by ESS showed the high discriminative power of this instrument. However, there was no significant difference in the SAQLI scores of patients with mild, moderate, and severe sleep apnea. The results of sensitivity to change verified that the SAQLI was able to detect changes after continuous positive airway pressure (CPAP) treatment. The findings of this study indicate that the Persian version of SAQLI is a reliable, valid, and responsive measure for evaluation of quality of life in patients with OSA.

  13. Development of a fulcrum methodology to replicate the lateral ankle sprain mechanism and measure dynamic inversion speed.

    PubMed

    Knight, Adam C; Weimar, Wendi H

    2012-09-01

    When the ankle is forced into inversion, the speed at which this movement occurs may affect the extent of injury. The purpose of this investigation was to develop a fulcrum device to mimic the mechanism of a lateral ankle sprain and to determine the reliability and validity of the temporal variables produced by this device. Additionally, this device was used to determine if a single previous lateral ankle sprain or ankle taping effected the time to maximum inversion and/or mean inversion speed. Twenty-six participants (13 with history of a single lateral ankle sprain and 13 with no history of injury) completed the testing. The participants completed testing on three separate days, performing 10 trials with the fulcrum per leg on each testing day, and tape was applied to both ankles on one testing day. No significant interactions or main effects were found for either previous injury or ankle taping, but good reliability was found for time to maximum inversion (ICC = .81) and mean inversion speed (ICC = .79). The findings suggest that although neither variable was influenced by the history of a single previous lateral ankle sprain or ankle taping, both variables demonstrated good reliability and construct validity, but not discriminative validity.

  14. The 10m incremental shuttle walk test is a highly reliable field exercise test for patients referred to cardiac rehabilitation: a retest reliability study.

    PubMed

    Hanson, Lisa C; Taylor, Nicholas F; McBurney, Helen

    2016-09-01

    To determine the retest reliability of the 10m incremental shuttle walk test (ISWT) in a mixed cardiac rehabilitation population. Participants completed two 10m ISWTs in a single session in a repeated measures study. Ten participants completed a third 10m ISWT as part of a pilot study. Hospital physiotherapy department. 62 adults aged a mean of 68 years (SD 10) referred to a cardiac rehabilitation program. Retest reliability of the 10m ISWT expressed as relative reliability and measurement error. Relative reliability was expressed in a ratio in the form of an intraclass correlation coefficient (ICC) and measurement error in the form of the standard error of measurement (SEM) and 95% confidence intervals for the group and individual. There was a high level of relative reliability over the two walks with an ICC of .99. The SEMagreement was 17m, and a change of at least 23m for the group and 54m for the individual would be required to be 95% confident of exceeding measurement error. The 10m ISWT demonstrated good retest reliability and is sufficiently reliable to be applied in practice in this population without the use of a practice test. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  15. Scale of attitudes toward alcohol - Spanish version: evidences of validity and reliability 1

    PubMed Central

    Ramírez, Erika Gisseth León; de Vargas, Divane

    2017-01-01

    ABSTRACT Objective: validate the Scale of attitudes toward alcohol, alcoholism and individuals with alcohol use disorders in its Spanish version. Method: methodological study, involving 300 Colombian nurses. Adopting the classical theory, confirmatory factor analysis was applied without prior examination, based on the strong historical evidence of the factorial structure of the original scale to determine the construct validity of this Spanish version. To assess the reliability, Cronbach’s Alpha and Mc Donalid’s Omega coefficients were used. Results: the confirmatory factor analysis indicated the good fit of the scale model in a four-factor distribution, with a cut-off point at 3.2, demonstrating 66.7% of sensitivity. Conclusions: the Scale of attitudes toward alcohol, alcoholism and individuals with alcohol use disorders in Spanish presented robust psychometric qualities, affirming that the instrument possesses a solid factorial structure and reliability and is capable of precisely measuring the nurses’ atittudes towards the phenomenon proposed. PMID:28793126

  16. Design and validation of the Health Professionals' Attitudes Toward the Homeless Inventory (HPATHI).

    PubMed

    Buck, David S; Monteiro, F Marconi; Kneuper, Suzanne; Rochon, Donna; Clark, Dana L; Melillo, Allegra; Volk, Robert J

    2005-01-10

    Recent literature has called for humanistic care of patients and for medical schools to begin incorporating humanism into medical education. To assess the attitudes of health-care professionals toward homeless patients and to demonstrate how those attitudes might impact optimal care, we developed and validated a new survey instrument, the Health Professional Attitudes Toward the Homeless Inventory (HPATHI). An instrument that measures providers' attitudes toward the homeless could offer meaningful information for the design and implementation of educational activities that foster more compassionate homeless health care. Our intention was to describe the process of designing and validating the new instrument and to discuss the usefulness of the instrument for assessing the impact of educational experiences that involve working directly with the homeless on the attitudes, interest, and confidence of medical students and other health-care professionals. The study consisted of three phases: identifying items for the instrument; pilot testing the initial instrument with a group of 72 third-year medical students; and modifying and administering the instrument in its revised form to 160 health-care professionals and third-year medical students. The instrument was analyzed for reliability and validity throughout the process. A 19-item version of the HPATHI had good internal consistency with a Cronbach's alpha of 0.88 and a test-retest reliability coefficient of 0.69. The HPATHI showed good concurrent validity, and respondents with more than one year of experience with homeless patients scored significantly higher than did those with less experience. Factor analysis yielded three subscales: Personal Advocacy, Social Advocacy, and Cynicism. The HPATHI demonstrated strong reliability for the total scale and satisfactory test-retest reliability. Extreme group comparisons suggested that experience with the homeless rather than medical training itself could affect health-care professionals' attitudes toward the homeless. This could have implications for the evaluation of medical school curricula.

  17. Development and validation of the Polish version of the Female Sexual Function Index in the Polish population of females.

    PubMed

    Nowosielski, Krzysztof; Wróbel, Beata; Sioma-Markowska, Urszula; Poręba, Ryszard

    2013-02-01

    Unlike male sexual function, which is relatively easy to assess, female sexual function is still a diagnostic challenge. Although numerous new measurements for female sexual dysfunction (FSD) have recently been developed, the Female Sexual Function Index (FSFI) remains the gold standard for screening. It has been validated in more than 30 countries. The FSFI has been used in several studies conducted in Poland, but it has never been standardized for Polish women. The aim of this study was to develop a Polish version of the FSFI (PL-FSFI). In total, 189 women aged 18-55 years were included in the study. Eighty-five were diagnosed with FSD as per the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM IV-TR) criteria; 104 women did not have FSD. All subjects completed the PL-FSFI at baseline (day 0), day 7, and day 28. Test-retest reliability was determined by Pearson's product-moment correlations. Reliability was tested using Cronbach's α coefficient. Construct validity was evaluated by principal component analysis using varimax rotation and factor analysis. Discriminant validity was assessed with between-groups analysis of variance. All domains of the PL-FSFI demonstrated satisfactory internal consistencies, with Cronbach's α value of >0.70 for the entire sample. The test-retest reliability demonstrated good-to-excellent agreement between the assessment points. Based on principal component analysis, a 5-factor model was established that explained 83.62% of the total variance. Domain intercorrelations of the PL-FSFI ranged from 0.37-0.77. The optimal PL-FSFI cutoff score was 27.50, with 87.1% sensitivity and 83.1% specificity. The PL-FSFI is a reliable questionnaire with good psychometric and discriminative validity. Therefore, it can be used as a tool for preliminary screening for FSD among Polish women. © 2012 International Society for Sexual Medicine.

  18. Evaluation of previously embolized intracranial aneurysms: inter-and intra-rater reliability among neurosurgeons and interventional neuroradiologists.

    PubMed

    Zuckerman, Scott L; Lakomkin, Nikita; Magarik, Jordan A; Vargas, Jan; Stephens, Marcus; Akinpelu, Babatunde; Spiotta, Alejandro M; Ahmed, Azam; Arthur, Adam S; Fiorella, David; Hanel, Ricardo; Hirsch, Joshua A; Hui, Ferdinand K; James, Robert F; Kallmes, David F; Meyers, Philip M; Niemann, David B; Rasmussen, Peter; Turner, Raymond D; Welch, Babu G; Mocco, J

    2018-05-01

    The angiographic evaluation of previously coiled aneurysms can be difficult yet remains critical for determining re-treatment. The main objective of this study was to determine the inter-rater reliability for both the Raymond Scale and per cent embolization among a group of neurointerventionalists evaluating previously embolized aneurysms. A panel of 15 neurointerventionalists examined 92 distinct cases of immediate post-coil embolization and 1 year post-embolization angiographs. Each case was presented four times throughout the study, along with alterations in demographics in order to evaluate intra-rater reliability. All respondents were asked to provide the per cent embolization (0-100%) and Raymond Scale grade (1-3) for each aneurysm. Inter-rater reliability was evaluated by computing weighted kappa values (for the Raymond Scale) and intraclass correlation coefficients (ICC) for per cent embolization. 10 neurosurgeons and 5 interventional neuroradiologists evaluated 368 simulated cases. The agreement among all readers employing the Raymond Scale was fair (κ=0.35) while concordance in per cent embolization was good (ICC=0.64). Clinicians with fewer than 10 years of experience demonstrated a significantly greater level of agreement than the group with greater than 10 years (κ=0.39 and ICC=0.70 vs κ=0.28 and ICC=0.58). When the same aneurysm was presented multiple times, clinicians demonstrated excellent consistency when assessing per cent embolization (ICC=0.82), but moderate agreement when employing the Raymond classification (κ=0.58). Identifying the per cent embolization in previously coiled aneurysms resulted in good inter- and intra-rater agreement, regardless of years of experience. The strong agreement among providers employing per cent embolization may make it a valuable tool for embolization assessment in this patient population. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. The psychometric properties of Observer OPTION(5), an observer measure of shared decision making.

    PubMed

    Barr, Paul J; O'Malley, Alistair James; Tsulukidze, Maka; Gionfriddo, Michael R; Montori, Victor; Elwyn, Glyn

    2015-08-01

    Observer OPTION(5) was designed as a more efficient version of OPTION(12), the most commonly used measure of shared decision making (SDM). The current paper assesses the psychometric properties of OPTION(5). Two raters used OPTION(5) to rate recordings of clinical encounters from two previous patient decision aid (PDA) trials (n=201; n=110). A subsample was re-rated two weeks later. We assessed discriminative validity, inter-rater reliability, intra-rater reliability, and concurrent validity. OPTION(5) demonstrated discriminative validity, with increases in SDM between usual care and PDA arms. OPTION(5) also demonstrated concurrent validity with OPTION(12), r=0.61 (95%CI 0.54, 0.68) and intra-rater reliability, r=0.93 (0.83, 0.97). The mean difference in rater score was 8.89 (95% Credibility Interval, 7.5, 10.3), with intraclass correlation (ICC) of 0.67 (95% Credibility Interval, 0.51, 0.91) for the accuracy of rater scores and 0.70 (95% Credibility Interval, 0.56, 0.94) for the consistency of rater scores across encounters, indicating good inter-rater reliability. Raters reported lower cognitive burden when using OPTION(5) compared to OPTION(12). OPTION(5) is a brief, theoretically grounded observer measure of SDM with promising psychometric properties in this sample and low burden on raters. OPTION(5) has potential to provide reliable, valid assessment of SDM in clinical encounters. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Assessing physiotherapists' communication skills for promoting patient autonomy for self-management: reliability and validity of the communication evaluation in rehabilitation tool.

    PubMed

    Murray, Aileen; Hall, Amanda; Williams, Geoffrey C; McDonough, Suzanne M; Ntoumanis, Nikos; Taylor, Ian; Jackson, Ben; Copsey, Bethan; Hurley, Deirdre A; Matthews, James

    2018-02-27

    To assess the inter-rater reliability and concurrent validity of the Communication Evaluation in Rehabilitation Tool, which aims to externally assess physiotherapists competency in using Self-Determination Theory-based communication strategies in practice. Audio recordings of initial consultations between 24 physiotherapists and 24 patients with chronic low back pain in four hospitals in Ireland were obtained as part of a larger randomised controlled trial. Three raters, all of whom had Ph.Ds in psychology and expertise in motivation and physical activity, independently listened to the 24 audio recordings and completed the 18-item Communication Evaluation in Rehabilitation Tool. Inter-rater reliability between all three raters was assessed using intraclass correlation coefficients. Concurrent validity was assessed using Pearson's r correlations with a reference standard, the Health Care Climate Questionnaire. The total score for the Communication Evaluation in Rehabilitation Tool is an average of all 18 items. Total scores demonstrated good inter-rater reliability (Intraclass Correlation Coefficient (ICC) = 0.8) and concurrent validity with the Health Care Climate Questionnaire total score (range: r = 0.7-0.88). Item-level scores of the Communication Evaluation in Rehabilitation Tool identified five items that need improvement. Results provide preliminary evidence to support future use and testing of the Communication Evaluation in Rehabilitation Tool. Implications for Rehabilitation Promoting patient autonomy is a learned skill and while interventions exist to train clinicians in these skills there are no tools to assess how well clinicians use these skills when interacting with a patient. The lack of robust assessment has severe implications regarding both the fidelity of clinician training packages and resulting outcomes for promoting patient autonomy. This study has developed a novel measurement tool Communication Evaluation in Rehabilitation Tool and a comprehensive user manual to assess how well health care providers use autonomy-supportive communication strategies in real world-clinical settings. This tool has demonstrated good inter-rater reliability and concurrent validity in its initial testing phase. The Communication Evaluation in Rehabilitation Tool can be used in future studies to assess autonomy-supportive communication and undergo further measurement property testing as per our recommendations.

  1. Rater reliability and construct validity of a mobile application for posture analysis

    PubMed Central

    Szucs, Kimberly A.; Brown, Elena V. Donoso

    2018-01-01

    [Purpose] Measurement of posture is important for those with a clinical diagnosis as well as researchers aiming to understand the impact of faulty postures on the development of musculoskeletal disorders. A reliable, cost-effective and low tech posture measure may be beneficial for research and clinical applications. The purpose of this study was to determine rater reliability and construct validity of a posture screening mobile application in healthy young adults. [Subjects and Methods] Pictures of subjects were taken in three standing positions. Two raters independently digitized the static standing posture image twice. The app calculated posture variables, including sagittal and coronal plane translations and angulations. Intra- and inter-rater reliability were calculated using the appropriate ICC models for complete agreement. Construct validity was determined through comparison of known groups using repeated measures ANOVA. [Results] Intra-rater reliability ranged from 0.71 to 0.99. Inter-rater reliability was good to excellent for all translations. ICCs were stronger for translations versus angulations. The construct validity analysis found that the app was able to detect the change in the four variables selected. [Conclusion] The posture mobile application has demonstrated strong rater reliability and preliminary evidence of construct validity. This application may have utility in clinical and research settings. PMID:29410561

  2. Rater reliability and construct validity of a mobile application for posture analysis.

    PubMed

    Szucs, Kimberly A; Brown, Elena V Donoso

    2018-01-01

    [Purpose] Measurement of posture is important for those with a clinical diagnosis as well as researchers aiming to understand the impact of faulty postures on the development of musculoskeletal disorders. A reliable, cost-effective and low tech posture measure may be beneficial for research and clinical applications. The purpose of this study was to determine rater reliability and construct validity of a posture screening mobile application in healthy young adults. [Subjects and Methods] Pictures of subjects were taken in three standing positions. Two raters independently digitized the static standing posture image twice. The app calculated posture variables, including sagittal and coronal plane translations and angulations. Intra- and inter-rater reliability were calculated using the appropriate ICC models for complete agreement. Construct validity was determined through comparison of known groups using repeated measures ANOVA. [Results] Intra-rater reliability ranged from 0.71 to 0.99. Inter-rater reliability was good to excellent for all translations. ICCs were stronger for translations versus angulations. The construct validity analysis found that the app was able to detect the change in the four variables selected. [Conclusion] The posture mobile application has demonstrated strong rater reliability and preliminary evidence of construct validity. This application may have utility in clinical and research settings.

  3. [Development of a Questionnaire Measuring Sexual Mental Health of Tibetan University Students].

    PubMed

    Chen, Jun-cheng; Yan, Yu-ruo; Ai, Li; Guo, Xue-hua; He, Jian-xiu; Yuan, Ping

    2016-05-01

    To develop a questionnaire measuring sexual mental health of Tibetan university students. A draft questionnaire was developed with reference to the Sexual Civilization Survey for University Students of New Century and other published literature, and in consultation with experts. The questionnaire was tested in 230 students. Exploratory factor analyses with principal component and varimax orthogonal rotation were performed. Common factors with a > 1 eigenvalues and ≥ 3 loaded items (factor loading ≥ 0.4) were retained. Items with a < 0.4 factor loading, < 0.2 commonality, or falling into a common factor with < 3 items were excluded. The revised questionnaire was administered in another sample of 481 university students. Cronbach's α and split-half reliabilities were estimated. Confirmatory factor analyses were performed to test the construct validity of the questionnaire. Four rounds of exploratory factor analyses reduced the draft questionnaire items from 39 to 34 with a 7-factor structure. The questionnaire had a Cronbach's α of 0.920, 0.898, 0.812, 0.844, 0.787, 0.684, 0.703, and 0.608, and a Spearman-Brown coefficient of 0.763, 0.867, 0.742, 0838, 0.746, 0.822, 0.677, and 0.564 for the overall questionnaire and its 7 domains, respectively, suggesting good internal reliability. The structural equation of confirmatory factor analysis fitted well with the raw data: fit index χ²/df 3.736; root mean square residual (RMR) 0.081; root mean square error of approximation (RMSEA = 0.076; goodness of fit index (GFI) 0.805; adjusted goodness of fit index (AGFI) 0.770; normed fit index (NFI) = 0.774; relative fit index (RFI) 0.749; incremental fit index (IFI) 0.824; non-normed fit index (NNFI) = 0.803; comparative fit index (CFI) = 0.823; parsimony goodness of fit index (PGFI) = 0.684; parsimony normed fit index (PNFI) = 0.698; parsimony comparative fit index (PCFI) = 0.742, suggesting good construct validity of the questionnaire. The Sexual Mental Health Questionnaire for Tibetan University Student has demonstrated good reliability and validity.

  4. Issues in cross-cultural validity: example from the adaptation, reliability, and validity testing of a Turkish version of the Stanford Health Assessment Questionnaire.

    PubMed

    Küçükdeveci, Ayse A; Sahin, Hülya; Ataman, Sebnem; Griffiths, Bridget; Tennant, Alan

    2004-02-15

    Guidelines have been established for cross-cultural adaptation of outcome measures. However, invariance across cultures must also be demonstrated through analysis of Differential Item Functioning (DIF). This is tested in the context of a Turkish adaptation of the Health Assessment Questionnaire (HAQ). Internal construct validity of the adapted HAQ is assessed by Rasch analysis; reliability, by internal consistency and the intraclass correlation coefficient; external construct validity, by association with impairments and American College of Rheumatology functional stages. Cross-cultural validity is tested through DIF by comparison with data from the UK version of the HAQ. The adapted version of the HAQ demonstrated good internal construct validity through fit of the data to the Rasch model (mean item fit 0.205; SD 0.998). Reliability was excellent (alpha = 0.97) and external construct validity was confirmed by expected associations. DIF for culture was found in only 1 item. Cross-cultural validity was found to be sufficient for use in international studies between the UK and Turkey. Future adaptation of instruments should include analysis of DIF at the field testing stage in the adaptation process.

  5. Validity and reliability of the Multidimensional Body Image Scale in Malaysian university students.

    PubMed

    Gan, W Y; Mohd, Nasir M T; Siti, Aishah H; Zalilah, M S

    2012-12-01

    This study aimed to evaluate the validity and reliability of the Multidimensional Body Image Scale (MBIS), a seven-factor, 62-item scale developed for Malaysian female adolescents. This scale was evaluated among male and female Malaysian university students. A total of 671 university students (52.2% women and 47.8% men) completed a self-administered questionnaire on MBIS, Eating Attitude Test-26, and Rosenberg Self-Esteem Scale. Their height and weight were measured. Results in confirmatory factor analysis showed that the 62-item MBIS reported poor fit to the data, xhi2/df = 4.126, p < 0.001, CFI = 0.808, SRMR = 0.070, RMSEA = 0.068 (90% CI = 0.067, 0.070). After re-specification of the model, the model fit was improved with 46 items remaining, chi2/df = 3.346, p < 0.001, CFI = 0.903, SRMR = 0.053, RMSEA = 0.059 (90% CI = 0.057, 0.061), and the model showed good fit to the data for men and women separately. This 46-item MBIS had good internal consistency in both men (Cronbach's alpha = 0.88) and women (Cronbach's alpha = 0.92). In terms of construct validity, it showed positive correlations with disordered eating and body weight status, but negative correlation with self-esteem. Also, this scale discriminated well between participants with and without disordered eating. The MBIS-46 demonstrated good reliability and validity for the evaluation of body image among university students. Further studies need to be conducted to confirm the validation results of the 46-item MBIS.

  6. How reliable and valid is the teacher version of the Strengths and Difficulties Questionnaire in primary school children?

    PubMed Central

    van den Heuvel, Meta; Jansen, Danielle E. M. C.; Stewart, Roy E.; Smits-Engelsman, Bouwien C. M.; Reijneveld, Sijmen A.; Flapper, Boudien C. T.

    2017-01-01

    Introduction The Strengths and Difficulties Questionnaire (SDQ) is validated for parents, but not yet for teachers in a broad age range of children. We conducted a cross-sectional study with 4–10 years old school children to investigate if the SDQ-T can be used instead of the validated but lengthy Teacher’s Report Form (TRF) to acquire information about emotional and behavioral problems in the school community. Methods Teachers of 453 children from primary schools were approached. Teachers of 394 children (response rate 86.9%) with a mean age of 7.1 years filled in the SDQ-T (n = 387), the TRF (n = 349) or both (n = 342). We assessed reliability by calculating internal consistency and concurrent validity (using correlation coefficients, sensitivity, specificity) of the SDQ-T compared with the TRF. Results Internal consistency of the SDQ-T Total Difficulties Score (SDQ-T TDS; Cronbach α = 0.80), hyperactivity/ inattention- (α = 0.86) and prosocial behavior (α = 0.81) was very good. Concurrent validity demonstrated a strong correlation of all subscales of the SDQ-T with the corresponding scale on the TRF (range 0.54–0.73), except for peer problems (0.46). Using a SDQ-T TDS cut-off score > 14, the SDQ-T had a good sensitivity (90%) and specificity (94%). Discussion The good reliability, validity and brevity of the SDQ-T make it an easily applicable questionnaire for obtaining information about emotional and behavioral problems from teachers in primary school children. PMID:28453573

  7. Reliability and Validity of the Korean Version of the Lifetime Stressor Checklist-Revised in Psychiatric Outpatients with Anxiety or Depressive Disorders.

    PubMed

    Choi, Kang Rok; Kim, Daeho; Jang, Eun Young; Bae, Hwallip; Kim, Seok Hyeon

    2017-01-01

    Traumatic events and adverse stressful experiences are major etiological factors in a wide variety of physical and mental disorders. Developing psychological instruments that can be easily administered and that have good psychometric properties have become an integral part for research and practice. This study investigated the reliability and validity of the Korean version of the Lifetime Stressor Checklist-Revised (LSC-R) in a consecutive sample of psychiatric outpatients. The LSC-R is a 30-item self-reporting questionnaire examining lifetime traumatic and non-traumatic stressors. A final sample of 258 outpatients with anxiety or depressive disorders was recruited at the psychiatric department of a university-affiliated teaching hospital. Self-reported data included the Life Events Checklist (LEC), the Zung Self-Rating Depression and Anxiety Scales, and the Impact of Events Scale-Revised, in addition to the LSC-R. A convenience sample of 50 college students completed the LSC-R on two occasions separated by a three week-interval for test-retest reliability. Mean kappa for temporal stability was high (κ=0.651) and Cronbach alpha was moderate (α=0.724). Convergent validity was excellent with corresponding items on the LEC. Concurrent validity was good for symptoms of post-traumatic stress disorder, depression, and anxiety. An exploratory factor analysis revealed that 11 factors explained 64.3 % of the total variance. This study demonstrated good psychometric properties of the Korean version of the LSC-R, further supporting its use in clinical research and practice with a Korean speaking population.

  8. Reliability of individual valuations of public and private goods: Choice consistency, response time, and preference refinement

    Treesearch

    Thomas C. Brown; David Kingsley; George L. Peterson; Nicholas E. Flores; Andrea Clarke; Andrej Birjulin

    2008-01-01

    We examined the reliability of a large set of paired comparison value judgments involving public goods, private goods, and sums of money. As respondents progressed through a random sequence of paired choices they were each given, their response time decreased and they became more consistent, apparently fine-tuning their responses, suggesting that respondents tend to...

  9. A Rapid Assessment Tool for affirming good practice in midwifery education programming.

    PubMed

    Fullerton, Judith T; Johnson, Peter; Lobe, Erika; Myint, Khine Haymar; Aung, Nan Nan; Moe, Thida; Linn, Nay Aung

    2016-03-01

    to design a criterion-referenced assessment tool that could be used globally in a rapid assessment of good practices and bottlenecks in midwifery education programs. a standard tool development process was followed, to generate standards and reference criteria; followed by external review and field testing to document psychometric properties. review of standards and scoring criteria were conducted by stakeholders around the globe. Field testing of the tool was conducted in Myanmar. eleven of Myanmar׳s 22 midwifery education programs participated in the assessment. the clinimetric tool was demonstrated to have content validity and high inter-rater reliability in use. a globally validated tool, and accompanying user guide and handbook are now available for conducting rapid assessments of compliance with good practice criteria in midwifery education programming. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Good match exploration for infrared face recognition

    NASA Astrophysics Data System (ADS)

    Yang, Changcai; Zhou, Huabing; Sun, Sheng; Liu, Renfeng; Zhao, Ji; Ma, Jiayi

    2014-11-01

    Establishing good feature correspondence is a critical prerequisite and a challenging task for infrared (IR) face recognition. Recent studies revealed that the scale invariant feature transform (SIFT) descriptor outperforms other local descriptors for feature matching. However, it only uses local appearance information for matching, and hence inevitably leads to a number of false matches. To address this issue, this paper explores global structure information (GSI) among SIFT correspondences, and proposes a new method SIFT-GSI for good match exploration. This is achieved by fitting a smooth mapping function for the underlying correct matches, which involves softassign and deterministic annealing. Quantitative comparisons with state-of-the-art methods on a publicly available IR human face database demonstrate that SIFT-GSI significantly outperforms other methods for feature matching, and hence it is able to improve the reliability of IR face recognition systems.

  11. Intra-rater and inter-rater reliability of ultrasonographic measurements of acromion-greater tuberosity distance in patients with post-stroke hemiplegia.

    PubMed

    Kumar, Praveen; Cruziah, Reynold; Bradley, Michael; Gray, Selena; Swinkels, Annette

    2016-06-01

    Glenohumeral subluxation (GHS) is reported in up to 81% of patients with stroke. Ultrasonographic measurements of GHS by measuring the acromion-greater tuberosity (AGT) have been found to be reliable for experienced raters. The primary aim was to assess the intra-rater reliability of measurements of AGT distance in people with stroke following a short course of rater training. A secondary aim was to compare the inter-rater reliability of these measurements between novice and experienced raters. Patients with stroke (n = 16; 5 men, 11 women; 74 ± 10 years) with 1-sided weakness who gave informed consent were recruited. Ultrasonographic measurements were recorded at the bedside by two physiotherapists with patients seated upright in a hospital chair. Reliability was assessed by intra-class correlation coefficients (ICCs) and the standard error of measurements (SEM). Minimum detectable change (MDC90) scores were used to estimate the magnitude of change that is likely to exceed measurement error. Mean ± SD AGT distances on the affected and unaffected sides for rater 1 were 2.2 ± 0.7 and 1.7 ± 0.4 cm, respectively. Corresponding values for rater 2 were 2.5 ± 0.6 and 2.0 ± 0.4 cm. Intra-class correlation coefficient values for the affected and unaffected shoulders for rater 1 were 0.96 and 0.91, respectively. Corresponding values for rater 2 were 0.95 and 0.90.SEM and MDC90 for both affected and unaffected shoulders were ≤ 0.2 cm. Inter-rater reliability coefficients were 0.86 (affected) and 0.76 (unaffected) shoulders. Ultrasonographic measurement of AGT distance demonstrates excellent intra-rater reliability for a novice rater. Inter-rater reliability of ultrasonographic measurement of AGT also demonstrates good reliability between novice and experienced raters.

  12. Quantifying the test-retest reliability of cerebral blood flow measurements in a clinical model of on-going post-surgical pain: A study using pseudo-continuous arterial spin labelling.

    PubMed

    Hodkinson, Duncan J; Krause, Kristina; Khawaja, Nadine; Renton, Tara F; Huggins, John P; Vennart, William; Thacker, Michael A; Mehta, Mitul A; Zelaya, Fernando O; Williams, Steven C R; Howard, Matthew A

    2013-01-01

    Arterial spin labelling (ASL) is increasingly being applied to study the cerebral response to pain in both experimental human models and patients with persistent pain. Despite its advantages, scanning time and reliability remain important issues in the clinical applicability of ASL. Here we present the test-retest analysis of concurrent pseudo-continuous ASL (pCASL) and visual analogue scale (VAS), in a clinical model of on-going pain following third molar extraction (TME). Using ICC performance measures, we were able to quantify the reliability of the post-surgical pain state and ΔCBF (change in CBF), both at the group and individual case level. Within-subject, the inter- and intra-session reliability of the post-surgical pain state was ranked good-to-excellent (ICC > 0.6) across both pCASL and VAS modalities. The parameter ΔCBF (change in CBF between pre- and post-surgical states) performed reliably (ICC > 0.4), provided that a single baseline condition (or the mean of more than one baseline) was used for subtraction. Between-subjects, the pCASL measurements in the post-surgical pain state and ΔCBF were both characterised as reliable (ICC > 0.4). However, the subjective VAS pain ratings demonstrated a significant contribution of pain state variability, which suggests diminished utility for interindividual comparisons. These analyses indicate that the pCASL imaging technique has considerable potential for the comparison of within- and between-subjects differences associated with pain-induced state changes and baseline differences in regional CBF. They also suggest that differences in baseline perfusion and functional lateralisation characteristics may play an important role in the overall reliability of the estimated changes in CBF. Repeated measures designs have the important advantage that they provide good reliability for comparing condition effects because all sources of variability between subjects are excluded from the experimental error. The ability to elicit reliable neural correlates of on-going pain using quantitative perfusion imaging may help support the conclusions derived from subjective self-report.

  13. Development and validation of a novel patient-reported treatment satisfaction measure for hyperfunctional facial lines: facial line satisfaction questionnaire.

    PubMed

    Pompilus, Farrah; Burgess, Somali; Hudgens, Stacie; Banderas, Benjamin; Daniels, Selena

    2015-12-01

    Facial lines or wrinkles are among the most visible signs of aging, and minimally invasive cosmetic procedures are becoming increasingly popular. The aim of this study was to develop and validate the Facial Line Satisfaction Questionnaire (FLSQ) for use in adults with upper facial lines (UFL). A literature review, concept elicitation interviews (n = 33), and cognitive debriefing interviews (n = 23) of adults with UFL were conducted to develop the FLSQ. The FLSQ comprises Baseline and Follow-up versions and was field-tested with 150 subjects in a US observational study designed to assess its psychometric performance. Analyses included acceptability (item and scale distribution [i.e. missingness, floor, and ceiling effects]), reliability, and validity (including concurrent validity). In total, 69 concepts were elicited during patient interviews. Following cognitive debriefing interviews, the FLSQ-Baseline version included 11 items and the Follow-up version included 13 items. Response rates for the FLSQ were 100% and 73% at baseline and follow-up, respectively; no items had excessive missing data. Questionnaire scale scores were normally distributed. Most domain scores demonstrated good internal consistency reliability (Cronbach's α ≥ 0.70). Most items within their respective domains exhibited good convergent (item-scale correlations > 0.40) and discriminant (items had higher correlation with their hypothesized scales than other scales) validity. Concurrent validity correlation coefficients of the FLSQ domain scores with the associated concurrent measures were acceptable (range: r = 0.40-0.70). Six FLSQ items demonstrated reliability and validity as stand-alone items outside their domains. The FLSQ is a valid questionnaire for assessing treatment expectations, satisfaction, impact, and preference in adults with UFL. © 2015 The Authors. Journal of Cosmetic Dermatology Published by Wiley Periodicals, Inc.

  14. An Observed Structured Teaching Evaluation Demonstrates the Impact of a Resident-as-Teacher Curriculum on Teaching Competency.

    PubMed

    Zackoff, Matthew; Jerardi, Karen; Unaka, Ndidi; Sucharew, Heidi; Klein, Melissa

    2015-06-01

    Residents play a critical role in the education of peers and medical students, yet attainment of teaching skills is not routinely assessed. The primary aim of this study was to develop a novel, skill-based Observed Structured Teaching Evaluation (OSTE) and self-assessment survey to measure the impact of a resident-as-teacher curriculum on teaching competency. The secondary aim was to determine interrater reliability of the OSTE. A prospective study quantitatively assessed intern teaching competency via videotaped teaching encounters (videos) before and after a month-long hospital medicine rotation and self-assessment surveys over a 5-month period. The intervention group received the resident-as-teacher curriculum. Videos were evaluated by 2 blinded faculty via an OSTE covering 9 skills within 3 core components: preparation, teaching, and reflection. Pre- to post-HM rotation month differences were evaluated within and between groups using the Wilcoxon signed rank test and Wilcoxon rank-sum test, respectively. Twenty-two of 25 (88%) control and 27 of 28 (96%) intervention interns participated; 100% of participants completed the study. The intervention group's pre-post difference for the total OSTE score and the average self-assessed competence statistically improved; however, no significant difference was seen between groups. The difference in preparation scores was significant for the intervention compared with the control. The OSTE's interrater reliability demonstrated good agreement with weighted kappas of 0.86 for preparation, 0.71 for teaching, and 0.93 for reflection. Implementation of an objective, skill-based OSTE detected observable changes in interns' teaching competency after implementation of a brief resident-as-teacher curriculum. The OSTE's good interrater reliability may allow standardized assessment of skill attainment over time. Copyright © 2015 by the American Academy of Pediatrics.

  15. Reliability and validity of the Japanese version of the Community Integration Measure for community-dwelling people with schizophrenia.

    PubMed

    Shioda, Ai; Tadaka, Etsuko; Okochi, Ayako

    2017-01-01

    Community integration is an essential right for people with schizophrenia that affects their well-being and quality of life, but no valid instrument exists to measure it in Japan. The aim of the present study is to develop and evaluate the reliability and validity of the Japanese version of the Community Integration Measure (CIM) for people with schizophrenia. The Japanese version of the CIM was developed as a self-administered questionnaire based on the original version of the CIM, which was developed by McColl et al. This study of the Japanese CIM had a cross-sectional design. Construct validity was determined using a confirmatory factor analysis (CFA) and data from 291 community-dwelling people with schizophrenia in Japan. Internal consistency was calculated using Cronbach's alpha. The Lubben Social Network Scale (LSNS-6), the Rosenberg Self-Esteem Scale (RSE) and the UCLA Loneliness Scale, version 3 (UCLALS) were administered to assess the criterion-related validity of the Japanese version of the CIM. The participants were 263 people with schizophrenia who provided valid responses. The Cronbach's alpha was 0.87, and CFA identified one domain with ten items that demonstrated the following values: goodness of fit index = 0.924, adjusted goodness of fit index = 0.881, comparative fit index = 0.925, and root mean square error of approximation = 0.085. The correlation coefficients were 0.43 (p < 0.001) with the LSNS-6, 0.42 (p < 0.001) with the RSE, and -0.57 (p < 0.001) with the UCLALS. The Japanese version of the CIM demonstrated adequate reliability and validity for assessing community integration for people with schizophrenia in Japan.

  16. The German Version of the Dutch Eating Behavior Questionnaire: Psychometric Properties, Measurement Invariance, and Population-Based Norms

    PubMed Central

    Hilbert, Anja; de Zwaan, Martina; Braehler, Elmar; Kersting, Anette

    2016-01-01

    The Dutch Eating Behavior Questionnaire is an internationally widely used instrument assessing different eating styles that may contribute to weight gain and overweight: emotional eating, external eating, and restraint. This study aimed to evaluate the psychometric properties of the 30-item German version of the DEBQ including its measurement invariance across gender, age, and BMI-status in a representative German population sample. Furthermore, we examined the distribution of eating styles in the general population and provide population-based norms for DEBQ scales. A representative sample of the German general population (N = 2513, age ≥ 14 years) was assessed with the German version of the DEBQ along with information on sociodemographic characteristics and body weight and height. The German version of the DEQB demonstrates good item characteristics and reliability (restraint: α = .92, emotional eating: α = .94, external eating: α = .89). The 3-factor structure of the DEBQ could be replicated in exploratory and confirmatory factor analyses and results of multi-group confirmatory factor analyses supported its metric and scalar measurement invariance across gender, age, and BMI-status. External eating was the most prevalent eating style in the German general population. Women scored higher on emotional and restrained eating scales than men, and overweight individuals scored higher in all three eating styles compared to normal weight individuals. Small differences across age were found for external eating. Norms were provided according to gender, age, and BMI-status. Our findings suggest that the German version of the DEBQ has good reliability and construct validity, and is suitable to reliably measure eating styles across age, gender, and BMI-status. Furthermore, the results demonstrate a considerable variation of eating styles across gender and BMI-status. PMID:27656879

  17. The German Version of the Dutch Eating Behavior Questionnaire: Psychometric Properties, Measurement Invariance, and Population-Based Norms.

    PubMed

    Nagl, Michaela; Hilbert, Anja; de Zwaan, Martina; Braehler, Elmar; Kersting, Anette

    The Dutch Eating Behavior Questionnaire is an internationally widely used instrument assessing different eating styles that may contribute to weight gain and overweight: emotional eating, external eating, and restraint. This study aimed to evaluate the psychometric properties of the 30-item German version of the DEBQ including its measurement invariance across gender, age, and BMI-status in a representative German population sample. Furthermore, we examined the distribution of eating styles in the general population and provide population-based norms for DEBQ scales. A representative sample of the German general population (N = 2513, age ≥ 14 years) was assessed with the German version of the DEBQ along with information on sociodemographic characteristics and body weight and height. The German version of the DEQB demonstrates good item characteristics and reliability (restraint: α = .92, emotional eating: α = .94, external eating: α = .89). The 3-factor structure of the DEBQ could be replicated in exploratory and confirmatory factor analyses and results of multi-group confirmatory factor analyses supported its metric and scalar measurement invariance across gender, age, and BMI-status. External eating was the most prevalent eating style in the German general population. Women scored higher on emotional and restrained eating scales than men, and overweight individuals scored higher in all three eating styles compared to normal weight individuals. Small differences across age were found for external eating. Norms were provided according to gender, age, and BMI-status. Our findings suggest that the German version of the DEBQ has good reliability and construct validity, and is suitable to reliably measure eating styles across age, gender, and BMI-status. Furthermore, the results demonstrate a considerable variation of eating styles across gender and BMI-status.

  18. Personality traits in companion dogs-Results from the VIDOPET.

    PubMed

    Turcsán, Borbála; Wallis, Lisa; Virányi, Zsófia; Range, Friederike; Müller, Corsin A; Huber, Ludwig; Riemer, Stefanie

    2018-01-01

    Individual behavioural differences in pet dogs are of great interest from a basic and applied research perspective. Most existing dog personality tests have specific (practical) goals in mind and so focused only on a limited aspect of dogs' personality, such as identifying problematic (aggressive or fearful) behaviours, assessing suitability as working dogs, or improving the results of adoption. Here we aimed to create a comprehensive test of personality in pet dogs that goes beyond traditional practical evaluations by exposing pet dogs to a range of situations they might encounter in everyday life. The Vienna Dog Personality Test (VIDOPET) consists of 15 subtests and was performed on 217 pet dogs. A two-step data reduction procedure (principal component analysis on each subtest followed by an exploratory factor analysis on the subtest components) yielded five factors: Sociability-obedience, Activity-independence, Novelty seeking, Problem orientation, and Frustration tolerance. A comprehensive evaluation of reliability and validity measures demonstrated excellent inter- and intra-observer reliability and adequate internal consistency of all factors. Moreover the test showed good temporal consistency when re-testing a subsample of dogs after an average of 3.8 years-a considerably longer test-retest interval than assessed for any other dog personality test, to our knowledge. The construct validity of the test was investigated by analysing the correlations between the results of video coding and video rating methods and the owners' assessment via a dog personality questionnaire. The results demonstrated good convergent as well as discriminant validity. To conclude, the VIDOPET is not only a highly reliable and valid tool for measuring dog personality, but also the first test to show consistent behavioural traits related to problem solving ability and frustration tolerance in pet dogs.

  19. Psychometric properties of the Persian version of the Time to Relapse Questionnaire (TRQ) in substance use disorder.

    PubMed

    Khazaee-Pool, Maryam; Moridi, Minoo; Ponnet, Koen; Turner, Nigel; Pashaei, Tahereh

    2016-11-01

    Predicting time to relapse provides an opportunity for the development of relapse prevention interventions in drug users. The aim of the present study was to describe the development of the Persian version of the 9-item Time to Relapse Questionnaire (TRQ) and to evaluate its psychometric properties in an Iranian sample of treatment-seeking individuals with substance dependence (n = 150). The forward-backward method was used to translate the TRQ scale from English into Persian. After linguistic validation and a pilot check, a cross-sectional study was performed, and psychometric properties of the Iranian version of the questionnaire were assessed. The reliability was evaluated by Cronbach's alpha and test-retest analyses. In addition, the factor structure of the scale was extracted by applying confirmatory factor analysis. The mean age of participants was 40.52 (SD = 11.30) years. The mean scores for the content validity index (CVI) and the content validity ratio (CVR) were 0.93 and 0.81, respectively. A confirmatory factor analysis (CFA) demonstrated that the three-factor model of the TRQ was a good fit for the data and thus replicated the factor structure of the original English language TRQ. Cronbach's alpha presented good internal consistency (alpha = 0.76), and test-retest reliability of the TRQ instrument with 2-week intervals was appropriate (ICC = 0.84). The findings demonstrate that the Persian version of the TRQ is a reliable and valid scale for measuring time to relapse in Iranian drug users. The TRQ can be applied at the start of treatment so that clinical interventions can be targeted toward the different relapse styles.

  20. Personality traits in companion dogs—Results from the VIDOPET

    PubMed Central

    Wallis, Lisa; Virányi, Zsófia; Range, Friederike; Müller, Corsin A.; Huber, Ludwig; Riemer, Stefanie

    2018-01-01

    Individual behavioural differences in pet dogs are of great interest from a basic and applied research perspective. Most existing dog personality tests have specific (practical) goals in mind and so focused only on a limited aspect of dogs’ personality, such as identifying problematic (aggressive or fearful) behaviours, assessing suitability as working dogs, or improving the results of adoption. Here we aimed to create a comprehensive test of personality in pet dogs that goes beyond traditional practical evaluations by exposing pet dogs to a range of situations they might encounter in everyday life. The Vienna Dog Personality Test (VIDOPET) consists of 15 subtests and was performed on 217 pet dogs. A two-step data reduction procedure (principal component analysis on each subtest followed by an exploratory factor analysis on the subtest components) yielded five factors: Sociability-obedience, Activity-independence, Novelty seeking, Problem orientation, and Frustration tolerance. A comprehensive evaluation of reliability and validity measures demonstrated excellent inter- and intra-observer reliability and adequate internal consistency of all factors. Moreover the test showed good temporal consistency when re-testing a subsample of dogs after an average of 3.8 years—a considerably longer test-retest interval than assessed for any other dog personality test, to our knowledge. The construct validity of the test was investigated by analysing the correlations between the results of video coding and video rating methods and the owners’ assessment via a dog personality questionnaire. The results demonstrated good convergent as well as discriminant validity. To conclude, the VIDOPET is not only a highly reliable and valid tool for measuring dog personality, but also the first test to show consistent behavioural traits related to problem solving ability and frustration tolerance in pet dogs. PMID:29634747

  1. Psychometric properties of Malay neuropsychiatry unit cognitive assessment tool among Alzheimer's disease patients in comparison to Malay Montreal Cognitive Assessment.

    PubMed

    Thong, Kai Shin; Chee, Kok Yoon; Ng, Chong Guan; Walterfang, Mark; Velakoulis, Dennis

    2016-09-01

    This study aims to establish psychometric properties of the Malay Neuropsychiatry Unit Cognitive Assessment Tool (Malay NuCOG) in Alzheimer's disease. NuCOG was translated to Malay language and compared with Montreal Cognitive Assessment Tool on 80 individuals. The Malay NuCOG showed good internal consistency and reliability (Cronbach's alpha = 0.895). It demonstrated 100% sensitivity and 87.5% specificity at the cutoff score of 78.50/100. The Malay NuCOG is a valid and reliable cognitive instrument that is sensitive and specific for the detection of dementia and has clinical advantages in its ability to examine individual cognitive domains. © 2015 Wiley Publishing Asia Pty Ltd.

  2. Using Item Response Theory to Develop a 60-Item Representation of the NEO PI-R Using the International Personality Item Pool: Development of the IPIP-NEO-60.

    PubMed

    Maples-Keller, Jessica L; Williamson, Rachel L; Sleep, Chelsea E; Carter, Nathan T; Campbell, W Keith; Miller, Joshua D

    2017-10-31

    Given advantages of freely available and modifiable measures, an increase in the use of measures developed from the International Personality Item Pool (IPIP), including the 300-item representation of the Revised NEO Personality Inventory (NEO PI-R; Costa & McCrae, 1992a ) has occurred. The focus of this study was to use item response theory to develop a 60-item, IPIP-based measure of the Five-Factor Model (FFM) that provides equal representation of the FFM facets and to test the reliability and convergent and criterion validity of this measure compared to the NEO Five Factor Inventory (NEO-FFI). In an undergraduate sample (n = 359), scores from the NEO-FFI and IPIP-NEO-60 demonstrated good reliability and convergent validity with the NEO PI-R and IPIP-NEO-300. Additionally, across criterion variables in the undergraduate sample as well as a community-based sample (n = 757), the NEO-FFI and IPIP-NEO-60 demonstrated similar nomological networks across a wide range of external variables (r ICC = .96). Finally, as expected, in an MTurk sample the IPIP-NEO-60 demonstrated advantages over the Big Five Inventory-2 (Soto & John, 2017 ; n = 342) with regard to the Agreeableness domain content. The results suggest strong reliability and validity of the IPIP-NEO-60 scores.

  3. Disability Measurement for Korean Community-Dwelling Adults With Stroke: Item-Level Psychometric Analysis of the Korean Longitudinal Study of Ageing

    PubMed Central

    2018-01-01

    Objective To investigate the psychometric properties of the activities of daily living (ADL) instrument used in the analysis of Korean Longitudinal Study of Ageing (KLoSA) dataset. Methods A retrospective study was carried out involving 2006 KLoSA records of community-dwelling adults diagnosed with stroke. The ADL instrument used for the analysis of KLoSA included 17 items, which were analyzed using Rasch modeling to develop a robust outcome measure. The unidimensionality of the ADL instrument was examined based on confirmatory factor analysis with a one-factor model. Item-level psychometric analysis of the ADL instrument included fit statistics, internal consistency, precision, and the item difficulty hierarchy. Results The study sample included a total of 201 community-dwelling adults (1.5% of the Korean population with an age over 45 years; mean age=70.0 years, SD=9.7) having a history of stroke. The ADL instrument demonstrated unidimensional construct. Two misfit items, money management (mean square [MnSq]=1.56, standardized Z-statistics [ZSTD]=2.3) and phone use (MnSq=1.78, ZSTD=2.3) were removed from the analysis. The remaining 15 items demonstrated good item fit, high internal consistency (person reliability=0.91), and good precision (person strata=3.48). The instrument precisely estimated person measures within a wide range of theta (−4.75 logits < θ < 3.97 logits) and a reliability of 0.9, with a conceptual hierarchy of item difficulty. Conclusion The findings indicate that the 15 ADL items met Rasch expectations of unidimensionality and demonstrated good psychometric properties. It is proposed that the validated ADL instrument can be used as a primary outcome measure for assessing longitudinal disability trajectories in the Korean adult population and can be employed for comparative analysis of international disability across national aging studies. PMID:29765888

  4. Reliability of peripheral arterial tonometry in patients with heart failure, diabetic nephropathy and arterial hypertension.

    PubMed

    Weisrock, Fabian; Fritschka, Max; Beckmann, Sebastian; Litmeier, Simon; Wagner, Josephine; Tahirovic, Elvis; Radenovic, Sara; Zelenak, Christine; Hashemi, Djawid; Busjahn, Andreas; Krahn, Thomas; Pieske, Burkert; Dinh, Wilfried; Düngen, Hans-Dirk

    2017-08-01

    Endothelial dysfunction plays a major role in cardiovascular diseases and pulse amplitude tonometry (PAT) offers a non-invasive way to assess endothelial dysfunction. However, data about the reliability of PAT in cardiovascular patient populations are scarce. Thus, we evaluated the test-retest reliability of PAT using the natural logarithmic transformed reactive hyperaemia index (LnRHI). Our cohort consisted of 91 patients (mean age: 65±9.7 years, 32% female), who were divided into four groups: those with heart failure with preserved ejection fraction (HFpEF) ( n=25), heart failure with reduced ejection fraction (HFrEF) ( n=22), diabetic nephropathy ( n=21), and arterial hypertension ( n=23). All subjects underwent two separate PAT measurements at a median interval of 7 days (range 4-14 days). LnRHI derived by PAT showed good reliability in subjects with diabetic nephropathy (intra-class correlation (ICC) = 0.863) and satisfactory reliability in patients with both HFpEF (ICC = 0.557) and HFrEF (ICC = 0.576). However, in subjects with arterial hypertension, reliability was poor (ICC = 0.125). We demonstrated that PAT is a reliable technique to assess endothelial dysfunction in adults with diabetic nephropathy, HFpEF or HFrEF. However, in subjects with arterial hypertension, we did not find sufficient reliability, which can possibly be attributed to variations in heart rate and the respective time of the assessments. Clinical Trial Registration Identifier: NCT02299960.

  5. Development and reliability of a preliminary Foot Osteoarthritis Magnetic Resonance Imaging Score

    PubMed Central

    Halstead, Jill; Martín-Hervás, Carmen; Hensor, Elizabeth MA; McGonagle, Dennis; Keenan, Anne-Maree

    2017-01-01

    Objective Foot osteoarthritis (OA) is very common but under-investigated musculoskeletal condition and there is little consensus as to common MRI imaging features. The aim of this study was to develop a preliminary foot OA MRI score (FOAMRIS) and evaluate its reliability. Methods This preliminary semi-quantitative score included the hindfoot, midfoot and metatarsophalangeal joints. Joints were scored for joint space narrowing (JSN, 0-3), osteophytes (0-3), joint effusion-synovitis and bone cysts (present/absent). Erosions and bone marrow lesions (BMLs) were scored (0-3) and BMLs were evaluated adjacent to entheses and at sub-tendon sites (present/absent). Additionally, tenosynovitis was scored (0-3) and midfoot ligament pathology was scored (present/absent). Reliability was evaluated in 15 people with foot pain and MRI-detected OA using 3.0T MRI multi-sequence protocols and assessed using intraclass correlation coefficients (ICC) as an overall score and per anatomical site (see supplementary data). Results Intra-reader agreement (ICC) was generally good to excellent across the foot in joint features (JSN 0.94, osteophytes 0.94, effusion-synovitis 0.62 and cysts 0.93), bone features (BML 0.89, erosion 0.78, BML-entheses 0.79, BML sub-tendon 0.75) and soft-tissue features (tenosynovitis 0.90, ligaments 0.87). Inter-reader agreement was lower for joint features (JSN 0.60, osteophytes 0.41, effusion-synovitis 0.03) and cysts 0.65, bone features (BML 0.80, erosion 0.00, BML-entheses 0.49, BML sub-tendon -0.24) and soft-tissue features (tenosynovitis 0.48, ligaments 0.50). Conclusion This preliminary FOAMRIS demonstrated good intra-reader reliability and fair inter-reader reliability when assessing the total feature scores. Further development is required in cohorts with a range of pathologies and to assess the psychometric measurement properties. PMID:28572462

  6. Validity and Reliability of the Persian Version of the Dysphagia Handicap Index (DHI).

    PubMed

    Asadollahpour, Faezeh; Baghban, Kowsar; Asadi, Mozhgan

    2015-05-01

    The Dysphagia Handicap Index (DHI) is one of the instruments used for measuring a dysphagic patient's self-assessment. In some ways, it reflects the patient's quality of life. Although it has been recognized and widely applied in English speaking populations, it has not been used in its present forms in Persian speaking countries. The purpose of this study was to adapt a Persian version of the DHI and to evaluate its validity, consistency, and reliability in the Persian population with oropharyngeal dysphagia. Some stages for cross-cultural adaptation were performed, which consisted in translation, synthesis, back translation, review by an expert committee, and final proof reading. The generated Persian DHI was administered to 85 patients with oropharyngeal dysphagia and 89 control subjects at Zahedan city between May 2013 and August 2013. The patients and control subjects answered the same questionnaire 2 weeks later to verify the test-retest reliability. Internal consistency and test-retest reliability were evaluated. The results of the patients and the control group were compared. The Persian DHI showed good internal consistency (Cronbach's alpha coefficients range from 0.82 to 0.94). Also, good test-retest reliability was found for the total scores of the Persian DHI (r=0.89). There was a significant difference between the DHI scores of the control group and those of the oropharyngeal dysphagia group (P‹0.001). The Persian version of the DHI achieved Face and translation validity. This study demonstrated that the Persian DHI is a valid tool for self-assessment of the handicapping effects of dysphagia on the physical, functional, and emotional aspects of patient life and can be a useful tool for screening and treatment planning for the Persian-speaking dysphagic patients, regardless of the cause or the severity of the dysphagia.

  7. A validation study on the traditional Chinese version of Spinal Appearance Questionnaire for adolescent idiopathic scoliosis.

    PubMed

    Guo, Jing; Lau, Ajax Hong Yin; Chau, Jack; Ng, Bobby Kin Wah; Lee, Kwong Man; Qiu, Yong; Cheng, Jack Chun Yiu; Lam, Tsz Ping

    2016-10-01

    "Simplified Chinese" version of Spinal Appearance Questionnaire (SC-SAQ) for patients with adolescent idiopathic scoliosis (AIS) was available but did not fit for communities using "Traditional Chinese" as their primary language. We developed a traditional Chinese version of SAQ (TC-SAQ) and evaluated its reliability and validity. TC-SAQ was administered to 112 AIS patients, of which 101 bilingual (English and Chinese) patients completed E-SAQ and the traditional Chinese version of Scoliosis Research Society-22 questionnaire (TC-SRS-22). Internal consistency and test-retest reliability were evaluated. Concurrent validity was evaluated by comparing TC-SAQ score with E-SAQ score, and convergent validity by comparing TC-SAQ score with TC-SRS-22 self-image domain score, and discriminant validity by analyzing the relationship between TC-SAQ score and patients' characteristics. Internal consistency of individual TC-SAQ domain was high (Cronbach's α = 0.785 to 0.940), except for general (Cronbach's α = 0.665) and shoulders (Cronbach's α = 0.421) domain. Test-retest reliability of TC-SAQ was good (ICCs of each domain from 0.798 to 0.865). Concurrent validity demonstrated an excellent correlation between TC-SAQ and E-SAQ scores (r = 0.820 to 0.954, P < 0.0001 for all domains). Correlation between TC-SAQ domains and TC-SRS-22 self-image domain was weak to moderate. TC-SAQ total score and individual domain scores (except waist and chest domains) were positively correlated to major curve magnitude. TC-SAQ had good internal consistency and test-retest reliability. Concurrent validity evaluated against the original English version was excellent. TC-SAQ was both reliable and valid for clinical use for AIS patients using traditional Chinese as their primary language.

  8. Reliability of intestinal temperature using an ingestible telemetry pill system during exercise in a hot environment.

    PubMed

    Ruddock, Alan D; Tew, Garry A; Purvis, Alison J

    2014-03-01

    Ingestible telemetry pill systems are being increasingly used to assess the intestinal temperature during exercise in hot environments. The purpose of this investigation was to assess the interday reliability of intestinal temperature during an exercise-heat challenge. Intestinal temperature was recorded as 12 physically active men (25 ± 4 years, stature 181.7 ± 7.0 cm, body mass 81.1 ± 10.6 kg) performed two 60-minute bouts of recumbent cycling (50% of peak aerobic power [watts]) in an environmental chamber set at 35° C 50% relative humidity 3-10 days apart. A range of statistics were used to calculate the reliability, including a paired t-test, 95% limits of agreement (LOA), coefficient of variation (CV), standard error of measurement (SEM), Pearson's correlation coefficient (r), intraclass correlation coefficient (ICC), and Cohen's d. Statistical significance was set at p ≤ 0.05. The method indicated a good overall reliability (LOA = ± 0.61° C, CV = 0.58%, SEM = 0.12° C, Cohen's d = 0.12, r = 0.84, ICC = 0.84). Analysis revealed a statistically significant (p = 0.02) mean systematic bias of -0.07 ± 0.31° C, and the investigation of the Bland-Altman plot suggested the presence of heteroscedasticity. Further analysis revealed the minimum "likely" change in intestinal temperature to be 0.34° C. Although the method demonstrates a good reliability, researchers should be aware of heteroscedasticity. Changes in intestinal temperature >0.34° C as a result of exercise or an intervention in a hot environment are likely changes and less influenced by error associated with the method.

  9. Development and Validation of a Fatigue Assessment Scale for U.S. Construction Workers

    PubMed Central

    Zhang, Mingzong; Sparer, Emily H.; Murphy, Lauren A.; Dennerlein, Jack T.; Fang, Dongping; Katz, Jeffrey N.; Caban-Martinez, Alberto J.

    2015-01-01

    Objective To develop a fatigue assessment scale and test its reliability and validity for commercial construction workers. Methods Using a two-phased approach, we first identified items for the development of a Fatigue Assessment Scale for Construction Workers (FASCW) through review of existing scales in the scientific literature, key informant interviews (n=11) and focus groups (3 groups with 6 workers each) with construction workers. The second phase included assessment for the reliability, validity and sensitivity of the new scale using a repeated-measures study design with a convenience sample of construction workers (n=144). Results Phase one resulted in a 16-item preliminary scale that after factor analysis yielded a final 10-item scale with two sub-scales (“Lethargy” and “Bodily Ailment”).. During phase two, the FASCW and its subscales demonstrated satisfactory internal consistency (alpha coefficients were FASCW (0.91), Lethargy (0.86) and Bodily Ailment (0.84)) and acceptable test-retest reliability (Pearson Correlations Coefficients: 0.59–0.68; Intraclass Correlation Coefficients: 0.74–0.80). Correlation analysis substantiated concurrent and convergent validity. A discriminant analysis demonstrated that the FASCW differentiated between groups with arthritis status and different work hours. Conclusions The 10-item FASCW with good reliability and validity is an effective tool for assessing the severity of fatigue among construction workers. PMID:25603944

  10. Do Choice Experiments Generate Reliable Willingness to Pay Estimates Theory and Experimental Evidence

    DTIC Science & Technology

    2015-01-01

    make a series of choices over sets of goods which vary in terms of the levels of their attributes and their costs. The results of these surveys...results motivated the development of the theoretical model reported in Part II, followed by a second experiment (reported in Part III) to test the...deviations from truthful preference revelation in each choice mechanism. The results demonstrate that of the four choice mechanisms tested , only the repeated

  11. Effective calculation of power system low-voltage solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Overbye, T.J.; Klump, R.P.

    1996-02-01

    This paper develops a method for reliably determining the set of low-voltage solutions which are closest to the operable power flow solution. These solutions are often used in conjunction with techniques such as energy methods and the voltage instability proximity index (VIPI) for assessing system voltage stability. This paper presents an algorithm which provides good initial guesses for these solutions. The results are demonstrated on a small system and on larger systems with up to 2,000 buses.

  12. The Employment Precariousness Scale (EPRES): psychometric properties of a new tool for epidemiological studies among waged and salaried workers.

    PubMed

    Vives, Alejandra; Amable, Marcelo; Ferrer, Montserrat; Moncada, Salvador; Llorens, Clara; Muntaner, Carles; Benavides, Fernando G; Benach, Joan

    2010-08-01

    Despite the fact that labour market flexibility has resulted in an expansion of precarious employment in industrialised countries, to date there is limited empirical evidence concerning its health consequences. The Employment Precariousness Scale (EPRES) is a newly developed, theory-based, multidimensional questionnaire specifically devised for epidemiological studies among waged and salaried workers. To assess the acceptability, reliability and construct validity of EPRES in a sample of waged and salaried workers in Spain. A sample of 6968 temporary and permanent workers from a population-based survey carried out in 2004-2005 was analysed. The survey questionnaire was interviewer administered and included the six EPRES subscales, and measures of the psychosocial work environment (COPSOQ ISTAS21) and perceived general and mental health (SF-36). A high response rate to all EPRES items indicated good acceptability; Cronbach's alpha coefficients, over 0.70 for all subscales and the global score, demonstrated good internal consistency reliability; exploratory factor analysis using principal axis analysis and varimax rotation confirmed the six-subscale structure and the theoretical allocation of all items. Patterns across known groups and correlation coefficients with psychosocial work environment measures and perceived health demonstrated the expected relations, providing evidence of construct validity. Our results provide evidence in support of the psychometric properties of EPRES, which appears to be a promising tool for the measurement of employment precariousness in public health research.

  13. Developing and validating the Youth Conduct Problems Scale-Rwanda: a mixed methods approach.

    PubMed

    Ng, Lauren C; Kanyanganzi, Frederick; Munyanah, Morris; Mushashi, Christine; Betancourt, Theresa S

    2014-01-01

    This study developed and validated the Youth Conduct Problems Scale-Rwanda (YCPS-R). Qualitative free listing (n = 74) and key informant interviews (n = 47) identified local conduct problems, which were compared to existing standardized conduct problem scales and used to develop the YCPS-R. The YCPS-R was cognitive tested by 12 youth and caregiver participants, and assessed for test-retest and inter-rater reliability in a sample of 64 youth. Finally, a purposive sample of 389 youth and their caregivers were enrolled in a validity study. Validity was assessed by comparing YCPS-R scores to conduct disorder, which was diagnosed with the Mini International Neuropsychiatric Interview for Children, and functional impairment scores on the World Health Organization Disability Assessment Schedule Child Version. ROC analyses assessed the YCPS-R's ability to discriminate between youth with and without conduct disorder. Qualitative data identified a local presentation of youth conduct problems that did not match previously standardized measures. Therefore, the YCPS-R was developed solely from local conduct problems. Cognitive testing indicated that the YCPS-R was understandable and required little modification. The YCPS-R demonstrated good reliability, construct, criterion, and discriminant validity, and fair classification accuracy. The YCPS-R is a locally-derived measure of Rwandan youth conduct problems that demonstrated good psychometric properties and could be used for further research.

  14. Validation of Malay Version of Snaith-Hamilton Pleasure Scale: Comparison between Depressed Patients and Healthy Subjects at an Out-Patient Clinic in Malaysia

    PubMed Central

    NG, Chong Guan; CHIN, Soo Cheng; YEE, Anne Hway Ann; LOH, Huai Seng; SULAIMAN, Ahmad Hatim; Sherianne Sook Kuan, WONG; HABIL, Mohamed Hussain

    2014-01-01

    Background: The Snaith-Hamilton Pleasure Scale (SHAPS) is a self-assessment scale designed to evaluate anhedonia in various psychiatric disorders. In order to facilitate its use in Malaysian settings, our current study aimed to examine the validity of a Malay-translated version of the SHAPS (SHAPS-M). Methods: In this cross-sectional study, a total of 44 depressed patients and 82 healthy subjects were recruited from a university out-patient clinic. All participants were given both the Malay and English versions of the SHAPS, Fawcett-Clark Pleasure Scale (FCPS), General Health Questionnaire 12 (GHQ-12), and the Beck Depression Inventory (BDI) to assess their hedonic state, general mental health condition and levels of depression. Results: The results showed that the SHAPS-M has impressive internal consistency (α = 0.96), concurrent validity and good parallel-form reliability (intraclass coefficient, ICC = 0.65). Conclusion: In addition to demonstrating good psychometric properties, the SHAPS-M is easy to administer. Therefore, it is a valid, reliable, and suitable questionnaire for assessing anhedonia among depressed patients in Malaysia. PMID:25246837

  15. Validation of Malay Version of Snaith-Hamilton Pleasure Scale: Comparison between Depressed Patients and Healthy Subjects at an Out-Patient Clinic in Malaysia.

    PubMed

    Ng, Chong Guan; Chin, Soo Cheng; Yee, Anne Hway Ann; Loh, Huai Seng; Sulaiman, Ahmad Hatim; Sherianne Sook Kuan, Wong; Habil, Mohamed Hussain

    2014-05-01

    The Snaith-Hamilton Pleasure Scale (SHAPS) is a self-assessment scale designed to evaluate anhedonia in various psychiatric disorders. In order to facilitate its use in Malaysian settings, our current study aimed to examine the validity of a Malay-translated version of the SHAPS (SHAPS-M). In this cross-sectional study, a total of 44 depressed patients and 82 healthy subjects were recruited from a university out-patient clinic. All participants were given both the Malay and English versions of the SHAPS, Fawcett-Clark Pleasure Scale (FCPS), General Health Questionnaire 12 (GHQ-12), and the Beck Depression Inventory (BDI) to assess their hedonic state, general mental health condition and levels of depression. The results showed that the SHAPS-M has impressive internal consistency (α = 0.96), concurrent validity and good parallel-form reliability (intraclass coefficient, ICC = 0.65). In addition to demonstrating good psychometric properties, the SHAPS-M is easy to administer. Therefore, it is a valid, reliable, and suitable questionnaire for assessing anhedonia among depressed patients in Malaysia.

  16. Development and Validation of a Nausea Severity Scale for Assessment of Nausea in Children with Abdominal Pain-Related Functional Gastrointestinal Disorders.

    PubMed

    Russell, Alexandra C; Stone, Amanda L; Wang, Andi; Walker, Lynn S

    2018-06-01

    The objective of this study was to develop a pediatric measure of chronic nausea severity, the Nausea Severity Scale (NSS), and evaluate its reliability and validity in youth with abdominal pain-related functional gastrointestinal disorders (AP-FGID). Pediatric patients (aged 11⁻17 years-old, n = 236) presenting to an outpatient clinic for evaluation of abdominal pain completed the NSS, Children's Somatization Inventory (CSI), Functional Disability Inventory (FDI), Abdominal Pain Index (API), Patient-Report Outcomes Measurement Information System (PROMIS), Anxiety and Depression Scales and the Pediatric Rome III Questionnaire for FGIDs. The NSS demonstrated good concurrent, discriminant, and construct validity, as well as good internal consistency. One-third (34%) of AP-FGID patients reported experiencing nausea "most" or "every day" in the previous two weeks. The severity of nausea was higher in females than males and correlated significantly with the severity of somatic symptoms, functional disability, anxiety, and depression. The NSS is a valid and reliable measure of nausea in children with AP-FGID.

  17. Development and validation of a tailored measure of body image for pregnant women.

    PubMed

    Watson, Brittany; Fuller-Tyszkiewicz, Matthew; Broadbent, Jaclyn; Skouteris, Helen

    2017-11-01

    This study developed and validated a quantitative measure of body image specifically designed for pregnancy-the Body Image in Pregnancy Scale (BIPS). Scale development was guided by qualitative data from a series of studies exploring the meaning of women's body image experiences during pregnancy, and previously established body image measures. Exploratory factor analysis for a sample of pregnant women (n = 251) indicated good fit for a 36-item scale with seven factors: preoccupation with physical appearance, dissatisfaction with physical strength, dissatisfaction with facial features, sexual attractiveness, prioritizing physical appearance over body functioning, appearance-related behavioral avoidance, and dissatisfaction with body parts. BIPS subscale scores demonstrated good internal reliability, test-retest reliability, and both incremental and convergent validity with measures of body image, self-esteem, and depressive symptomatology. Although the pregnancy-focused wording of BIPS items prevents its use for comparisons with nonpregnant populations, further testing of changes in body image throughout pregnancy is an identified area for further research with this measure. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. The preliminary analysis of the reliability and validity of the Chinese Edition of the CSBS DP.

    PubMed

    Lin, Chu-Sui; Chang, Shu-Hui; Cheng, Shu-Fen; Chao, Pen-Chiang; Chiu, Chun-Hao

    2015-03-01

    This study marked a preliminary attempt to standardize the Chinese Edition of the Communication and Symbolic Behavior Scales Developmental Profile (Wetherby & Prizant, 2002; CSBS DP) to assist in the early identification of young children with special needs in Taiwan. The study was conducted among 171 infants and toddlers aged 1-2. It also included a follow-up study one year after the initial test. Three domestically developed standardized child development inventories were used to measure the concurrent validity and predictive validity. The Chinese Edition of the CSBS DP demonstrated overall good test-retest and inter-rater reliability. It also showed good concurrent and predictive validity. The current study yields preliminary evidence that the Chinese Edition of the CSBS DP could be a valuable assessment tool worthy of wider distribution. Future research should employ random sampling to establish a true national norm. Additionally, the follow-up study needs to include atypical groups and to expand to children aged 6-12 months to strengthen the applicability of the instrument in Taiwan. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. PubMed Central

    Giusti, P.; Mancini, V.; Grosso, M.; Barillari, M.R.; Bastiani, L.; Molinaro, S.; Nacci, A.

    2016-01-01

    SUMMARY The purpose of this study was to compare videofluoroscopy (VFS), fiberoptic endoscopic evaluation of swallowing (FEES) and oro-pharyngo- oesophageal scintigraphy (OPES) with regards to premature spillage, post-swallowing residue and aspiration to assess the reliability of these tests for detection of oro-pharyngeal dysphagia. Sixty patients affected with dysphagia of various origin were enrolled in the study and submitted to VFS, FEES and OPES using a liquid and semi-solid bolus. As a reference, we used VFS. Both the FEES and the OPES showed good sensitivity with high overall values (≥ 80% and ≥ 90% respectively). The comparison between FEES vs VFS concerning drop before swallowing showed good specificity (84.4% for semi-solids and 86.7% for liquids). In the case of post-swallowing residue, FEES vs VFS revealed good overall validity (75% for semi-solids) with specificity and sensitivity well balanced for the semi-solids. OPES vs. VFS demonstrated good sensitivity (88.6%) and overall validity (76.7%) for liquids. The analysis of FEES vs. VFS for aspiration showed that the overall validity was low (≤ 65%). On the other hand, OPES demonstrated appreciable overall validity (71.7%). VFS, FEES and OPES are capable of detecting oro-pharyngeal dysphagia. FEES gave significant results in the evaluation of post-swallowing residues. PMID:27958600

  20. The validity and reliability of tinnitus handicap inventory Thai version.

    PubMed

    Limviriyakul, Siriporn; Supavanich, Walop

    2012-11-01

    Demonstrate the reliability and validity of the Tinnitus Handicap Inventory Thai Version (THI-T), a self-report measure of tinnitus. A cross-sectional psychometric validation study was used to determine internal consistency reliability and validity of the Tinnitus Handicap Inventory Thai Version at the Otoneurology clinic at Tertiary care center The cross-cultural adaptation of the Tinnitus Handicapped Inventory English version (Newman et al, 1996) was translated into Thai version following the steps indicated by Guillemin et al. The reliability was constructed by using Cronbach's coefficient alpha. The validity was analyzed by the correlation between Tinnitus Handicap Inventory Thai version and the 36-items short form health survey and visual analog scale using Spearman and Pearson test. The result showed good internal consistency reliabilities of total, functional, emotional, and catastrophic scale (a = 0.902, 0.804, 0.831 and 0.661, respectively) of Tinnitus Handicap Inventory Thai Version. Spearman correlation showed the significant correlation of Tinnitus Handicap Inventory to 36-items short form health survey and visual analog scale. Tinnitus Handicap Inventory Thai Version will be a vigorous tool in evaluating tinnitus patients as well as monitoring the progress of their symptoms.

  1. Examining the validity and reliability of the Taita symptom checklist using Rasch analysis.

    PubMed

    Chen, Yun-Ling; Pan, Ay-Woan; Chung, LyInn; Chen, Tsyr-Jang

    2015-03-01

    The Taita symptom checklist (TSCL) is a standardized self-rating psychiatric symptom scale for outpatients with mental illness in Taiwan. This study aimed to examine the validity and reliability of the TSCL using Rasch analysis. The TSCL was given to 583 healthy people and 479 people with mental illness. Rasch analysis was used to examine the appropriateness of the rating scale, the unidimensionality of the scale, the differential item functioning across sex and diagnosis, and the Rasch cut-off score of the scale. Rasch analysis confirmed that the revised 37 items with a three-point rating scale of the TSCL demonstrated good internal consistency and met criteria for unidimensionality. The person and item reliability indices were high. The TSCL could reliably measure healthy participants and patients with mental illness. Differential item functioning due to sex or psychiatric diagnosis was evident for three items. A Rasch cut-off score for TSCL was produced for detecting participants' psychiatric symptoms based on an eight-level classification. The TSCL is a reliable and valid assessment to evaluate the participants' perceived disturbance of psychiatric symptoms based on Rasch analysis. Copyright © 2013. Published by Elsevier B.V.

  2. Reliability and Validity of the Korean Version of the Internet Addiction Test among College Students

    PubMed Central

    Lee, Kounseok; Lee, Hye-Kyung; Gyeong, Hyunsu; Yu, Byeongkwan; Song, Yul-Mai

    2013-01-01

    We developed a Korean translation of the Internet Addiction Test (KIAT), widely used self-report for internet addiction and tested its reliability and validity in a sample of college students. Two hundred seventy-nine college students at a national university completed the KIAT. Internal consistency and two week test-retest reliability were calculated from the data, and principal component factor analysis was conducted. Participants also completed the Internet Addiction Diagnostic Questionnaire (IADQ), the Korea Internet addiction scale (K-scale), and the Patient Health Questionnaire-9 for the criterion validity. Cronbach's alpha of the whole scale was 0.91, and test-retest reliability was also good (r = 0.73). The IADQ, the K-scale, and depressive symptoms were significantly correlated with the KIAT scores, demonstrating concurrent and convergent validity. The factor analysis extracted four factors (Excessive use, Dependence, Withdrawal, and Avoidance of reality) that accounted for 59% of total variance. The KIAT has outstanding internal consistency and high test-retest reliability. Also, the factor structure and validity data show that the KIAT is comparable to the original version. Thus, the KIAT is a psychometrically sound tool for assessing internet addiction in the Korean-speaking population. PMID:23678270

  3. Reliability, Validity, and Sensitivity to Change Overtime of the Modified Melasma Area and Severity Index Score.

    PubMed

    Abou-Taleb, Doaa A E; Ibrahim, Ahmed K; Youssef, Eman M K; Moubasher, Alaa E A

    2017-02-01

    The new modified Melasma Area and Severity Index (mMASI) score, the recently used outcome measure for melasma, has not been tested to determine its sensitivity to change in melasma. To determine the reliability, validity, and sensitivity to change overtime of the mMASI score in assessment of the severity of melasma. Pearson correlation, Cronbach alpha, and intraclass correlation coefficient were calculated to assess the reliability of the mMASI score. Validity of the mMASI scale was carried out using Spearman correlation between mMASI total score (before and after treatment), clinical data, and patient's responses. The mMASI score showed excellent reliability and good validity for assessment of the severity of melasma. The authors also determined that the mMASI score demonstrated sensitivity to change over time. An excellent degree of agreement between the mMSAI and MASI scores was revealed. The mMASI score is reliable, valid, and responsive to change in the assessment of severity of melasma. Moreover, the mMASI score was found to be easier to learn and perform and simpler in calculation compared with the MASI score. Overall, the mMASI score can effectively replace the MASI score.

  4. Factor structure, reliability, and validity of the Japanese version of the Hoarding Rating Scale-Self-Report (HRS-SR-J).

    PubMed

    Tsuchiyagaito, Aki; Horiuchi, Satoshi; Igarashi, Toko; Kawanori, Yoshiya; Hirano, Yoshiyuki; Yabe, Hirooki; Nakagawa, Akiko

    2017-01-01

    The Hoarding Rating Scale-Self-Report (HRS-SR) is a five-item scale that assesses the symptoms of hoarding. These symptoms include excessive acquisition, difficulty in discarding, and excessive clutter that causes distress. We conducted three studies to examine the factor structure, reliability, and validity of the Japanese version of the HRS-SR (HRS-SR-J). Study 1 examined its reliability; 193 college students and 320 adolescents and adults completed the HRS-SR-J and, of the college students, 32 took it again 2 weeks later. Study 2 aimed to confirm that its scores in a sample of 210 adolescents and adults are independent of social desirability. Study 3 aimed to validate the HRS-SR-J in the aspects of convergent and discriminant validity in a sample of 550 adults. The HRS-SR-J showed good internal consistency and 2-week test-retest reliability. Based on the nonsignificant correlations between the HRS-SR-J and social desirability, the HRS-SR-J was not strongly affected by social desirability. In addition, it also had a good convergent validity with the Japanese version of the Saving Inventory-Revised (SI-R-J) and the hoarding subscale of the Obsessive-Compulsive Inventory, while having a significantly weaker correlation with the five subscales of the Obsessive-Compulsive Inventory, except for the hoarding subscale. In addition, the strength of the correlation between the HRS-SR-J and the Japanese version of the Patient Health Questionnaire-9 and that between the HRS-SR-J and the Generalized Anxiety Disorder-7 were significantly weaker than the correlation between the HRS-SR-J and the SI-R-J. These results demonstrate that the HRS-SR-J has good convergent and discriminant validity. The HRS-SR-J is a notable self-report scale for examining the severity of hoarding symptoms.

  5. Accuracy and reliability testing of two methods to measure internal rotation of the glenohumeral joint.

    PubMed

    Hall, Justin M; Azar, Frederick M; Miller, Robert H; Smith, Richard; Throckmorton, Thomas W

    2014-09-01

    We compared accuracy and reliability of a traditional method of measurement (most cephalad vertebral spinous process that can be reached by a patient with the extended thumb) to estimates made with the shoulder in abduction to determine if there were differences between the two methods. Six physicians with fellowship training in sports medicine or shoulder surgery estimated measurements in 48 healthy volunteers. Three were randomly chosen to make estimates of both internal rotation measurements for each volunteer. An independent observer made objective measurements on lateral scoliosis films (spinous process method) or with a goniometer (abduction method). Examiners were blinded to objective measurements as well as to previous estimates. Intraclass coefficients for interobserver reliability for the traditional method averaged 0.75, indicating good agreement among observers. The difference in vertebral level estimated by the examiner and the actual radiographic level averaged 1.8 levels. The intraclass coefficient for interobserver reliability for the abduction method averaged 0.81 for all examiners, indicating near-perfect agreement. Confidence intervals indicated that estimates were an average of 8° different from the objective goniometer measurements. Pearson correlation coefficients of intraobserver reliability for the abduction method averaged 0.94, indicating near-perfect agreement within observers. Confidence intervals demonstrated repeated estimates between 5° and 10° of the original. Internal rotation estimates made with the shoulder abducted demonstrated interobserver reliability superior to that of spinous process estimates, and reproducibility was high. On the basis of this finding, we now take glenohumeral internal rotation measurements with the shoulder in abduction and use a goniometer to maximize accuracy and objectivity. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. COMPI Fertility Problem Stress Scales is a brief, valid and reliable tool for assessing stress in patients seeking treatment.

    PubMed

    Sobral, Maria P; Costa, Maria E; Schmidt, Lone; Martins, Mariana V

    2017-02-01

    Are the Copenhagen Multi-Centre Psychosocial Infertility research program Fertility Problem Stress Scales (COMPI-FPSS) a reliable and valid measure across gender and culture? The COMPI-FPSS is a valid and reliable measure, presenting excellent or good fit in the majority of the analyzed countries, and demonstrating full invariance across genders and partial invariance across cultures. Cross-cultural and gender validation is needed to consider a measure as standard care within fertility. The present study is the first attempting to establish comparability of fertility-related stress across genders and countries. Cross-sectional study. First, we tested the structure of the COMPI-FPSS. Then, reliability and validity (convergent and discriminant) were examined for the final model. Finally, measurement invariance both across genders and cultures was tested. Our final sample had 3923 fertility patients (1691 men and 2232 women) recruited in clinical settings from seven different countries: Denmark, China, Croatia, Germany, Greece, Hungary and Sweden. Participants had a mean age of 34 years and the majority (84%) were childless. Findings confirmed the original three-factor structure of the COMPI-FPSS, although suggesting a shortened measurement model using less items that fitted the data better than the full version model. While data from the Chinese and Croatian subsamples did not fit, all other counties presented good fit (χ 2 /df ≤ 5.4; comparative fit index ≥ 0.94; root-mean-square error of approximation ≤ 0.07; modified expected cross-validation index ≤ 0.77). In general, reliability, convergent validity, and discriminant validity were observed in all subscales from each country (composite reliability ≥ 0.63; average variance extracted ≥ 0.38; squared correlation ≥ 0.13). Full invariance was established across genders, and partial invariance was demonstrated across countries. Generalizability regarding the validation of the COMPI-FPSS cannot be made regarding infertile individuals not seeking treatment, or non-European patients. This study did not investigate predictive validity, and hence the capability of this instrument in detecting changes in fertility-specific adjustment over time and predicting the psychological impact needs to be established in future research. Besides extending knowledge on the psychometric properties of one of the most used fertility stress questionnaire, this study demonstrates both research and clinical usefulness of the COMPI-FPSS. This study was supported by European Union Funds (FEDER/COMPETE-Operational Competitiveness Program, and by national funds (FCT-Portuguese Foundation for Science and Technology) under the projects PTDC/MHC-PSC/4195/2012 and SFRH/BPD/85789/2012). There are no conflicts of interest to declare. N/A. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. The Brighton musculoskeletal Patient-Reported Outcome Measure (BmPROM): An assessment of validity, reliability, and responsiveness.

    PubMed

    Bryant, Elizabeth; Murtagh, Shemane; Finucane, Laura; McCrum, Carol; Mercer, Christopher; Smith, Toby; Canby, Guy; Rowe, David A; Moore, Ann P

    2018-05-11

    In response for the need of a freely available, stand-alone, validated outcome measure for use within musculoskeletal (MSK) physiotherapy practice, sensitive enough to measure clinical effectiveness, we developed an MSK patient reported outcome measure. This study examined the validity and reliability of the newly developed Brighton musculoskeletal Patient-Reported Outcome Measure (BmPROM) within physiotherapy outpatient settings. Two hundred twenty-four patients attending physiotherapy outpatient departments in South East England with an MSK condition participated in this study. The BmPROM was assessed for user friendliness (rated feedback, N = 224), reliability (internal consistency and test-retest reliability, n = 42), validity (internal and external construct validity, N = 224), and responsiveness (internal, n = 25). Exploratory factor analysis indicated that a two-factor model provides a good fit to the data. Factors were representative of "Functionality" and "Wellbeing". Correlations observed between the BmPROM and SF-36 domains provided evidence of convergent validity. Reliability results indicated that both subscales were internally consistent with alphas above the acceptable limits for both "Functionality" (α = .85, 95% CI [.81, .88]) and 'Wellbeing' (α = .80, 95% CI [.75, .84]). Test-retest analyses (n = 42) demonstrated a high degree of reliability between "Functionality" (ICC = .84; 95% CI [.72, .91]) and "Wellbeing" scores (ICC = .84; 95% CI [.72, .91]). Further examination of test-retest reliability through the Bland-Altman analysis demonstrated that the difference between "Functionality" and "Wellbeing" test scores did not vary as a function of absolute test score. Large treatment effect sizes were found for both subscales (Functionality d = 1.10; Wellbeing 1.03). The BmPROM is a reliable and valid outcome measure for use in evaluating physiotherapy treatment of MSK conditions. Copyright © 2018 John Wiley & Sons, Ltd.

  8. Inter-rater reliability of three standardized functional tests in patients with low back pain

    PubMed Central

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar stability is required. PMID:19490644

  9. The Reliability and Validity of Measures of Gait Variability in Community-Dwelling Older Adults

    PubMed Central

    Brach, Jennifer S.; Perera, Subashan; Studenski, Stephanie; Newman, Anne B.

    2009-01-01

    Objective To examine the test-retest reliability and concurrent validity of variability of gait characteristics. Design Cross-sectional study. Setting Research laboratory. Participants Older adults (N=558) from the Cardiovascular Health Study. Interventions Not applicable. Main Outcome Measures Gait characteristics were measured using a 4-m computerized walkway. SD determined from the steps recorded were used as the measures of variability. Intraclass correlation coefficients (ICC) were calculated to examine test-retest reliability of a 4-m walk and two 4-m walks. To establish concurrent validity, the measures of gait variability were compared across levels of health, functional status, and physical activity using independent t tests and analysis of variances. Results Gait variability measures from the two 4-m walks demonstrated greater test-retest reliability than those from the single 4-m walk (ICC=.22–.48 and ICC=.40–.63, respectively). Greater step length and stance time variability were associated with poorer health, functional status and physical activity (P<.05). Conclusions Gait variability calculated from a limited number of steps has fair to good test-retest reliability and concurrent validity. Reliability of gait variability calculated from a greater number of steps should be assessed to determine if the consistency can be improved. PMID:19061741

  10. The DASS-14: Improving the Construct Validity and Reliability of the Depression, Anxiety, and Stress Scale in a Cohort of Health Professionals.

    PubMed

    Wise, Frances M; Harris, Darren W; Olver, John H

    2017-01-01

    Considerable research has been undertaken in evaluating the DASS-21 in a variety of clinical populations, but studies of the instrument's psychometric adequacy in healthcare professionals is lacking. This study aimed to establish and improve the construct validity and reliability of the DASS-21 in a cohort of Australian health professionals. 343 rehabilitation health professionals completed the DASS-21, along with a demographic questionnaire. Principal components analysis was performed to identify potential factors in the DASS-21. Factors were interpreted against theoretical constructs underlying the instrument. Items loading on separate factors were then subjected to reliability analysis to determine internal consistency of subscales. Items that demonstrated poor fit, or loaded onto more than one factor, were deleted to maximise the reliability of each subscale. Principal components analysis identified three dimensions (depression, anxiety, stress) in a modified version of the DASS-21 (renamed DASS-14), with appropriate construct validity and good reliability (a=0.73 to 0.88). The three dimensions accounted for over 62% of variance between items. The modified DASS-14 scale is a more parsimonious measure of depression, anxiety, and stress, with acceptable reliability and construct validity, in rehabilitation health professionals and is appropriate for use in studies of similar populations.

  11. Reliability of digital photography for assessing lower extremity alignment in individuals with flatfeet and normal feet types.

    PubMed

    Ashnagar, Zinat; Hadian, Mohammad Reza; Olyaei, Gholamreza; Talebian Moghadam, Saeed; Rezasoltani, Asghar; Saeedi, Hassan; Yekaninejad, Mir Saeed; Mahmoodi, Rahimeh

    2017-07-01

    The aim of this study was to investigate the intratester reliability of digital photographic method for quantifying static lower extremity alignment in individuals with flatfeet and normal feet types. Thirteen females with flexible flatfeet and nine females with normal feet types were recruited from university communities. Reflective markers were attached over the participant's body landmarks. Frontal and sagittal plane photographs were taken while the participants were in a standardized standing position. The markers were removed and after 30 min the same procedure was repeated. Pelvic angle, quadriceps angle, tibiofemoral angle, genu recurvatum, femur length and tibia length were measured from photographs using the Image j software. All measured variables demonstrated good to excellent intratester reliability using digital photography in both flatfeet (ICC: 0.79-0.93) and normal feet type (ICC: 0.84-0.97) groups. The findings of the current study indicate that digital photography is a highly reliable method of measurement for assessing lower extremity alignment in both flatfeet and normal feet type groups. Copyright © 2016. Published by Elsevier Ltd.

  12. Reliability and validity of the Arabic version of the computerized Battery for Neuropsychological Evaluation of Children (BENCI).

    PubMed

    Fasfous, Ahmed F; Peralta-Ramirez, Maria Isabel; Pérez-Marfil, María Nieves; Cruz-Quintana, Francisco; Catena-Martinez, Andrés; Pérez-García, Miguel

    2015-01-01

    Batería de Evaluación Neuropsicológica Infantil (BENCI) is a computerized battery for the neuropsychological evaluation of children. This battery has been used in different studies to evaluate neuropsychological functions and neurodevelopment in children. The objective of this study is to test the validity and reliability of the first Arabic version of the BENCI on an Arabic population where neuropsychological tests are very scarce. We administrate the BENCI to 198 school-age children (98 boys and 100 girls) from Morocco. To examine the test retest reliability of the BENCI battery, we administered the battery 2 times to 43 children (23 boys and 20 girls) with 15 days in between the pre- and posttest. The results revealed good validity and reliability of the battery in Arabic children. Also, the BENCI battery has demonstrated the capacity to differentiate between children by their age group. This battery can be of great use to both the research and clinical areas of Arabic countries and/or in assistance to Arabic immigrants that live outside of their native country.

  13. The kinematics of upper extremity reaching: a reliability study on people with and without shoulder impingement syndrome

    PubMed Central

    2010-01-01

    Background Tasks chosen to evaluate motor performance should reflect the movement deficits characteristic of the target population and present an appropriate challenge for the patients who would be evaluated. A reaching task that evaluates impairment characteristics of people with shoulder impingement syndrome (SIS) was developed to evaluate the motor performance of this population. The objectives of this study were to characterize the reproducibility of this reaching task in people with and without SIS and to evaluate the impact of the number of trials on reproducibility. Methods Thirty subjects with SIS and twenty healthy subjects participated in the first measurement session to evaluate intrasession reliability. Ten healthy subjects were retested within 2 to 7 days to assess intersession reliability. At each measurement session, upper extremity kinematic patterns were evaluated during a reaching task. Ten trials were recorded. Thereafter, the upper extremity position at the end of reaching and total joint excursion that occurred during reaching were calculated. Intraclass correlation coefficient (ICC) and minimal detectable change (MDC) were used to estimate intra and intersession reliability. Results Intrasession reliability for total joint excursion was good to very good when based on the first two trials (0.770.92). As for end-reach position, intrasession reliability was very good when using either the first two, first five or last five trials (ICC>0.82). Globally, MDC were smaller for the last five trials. Intersession reliability of total joint excursion and position at the end of reaching was good to very good when using the mean of the first two or five trials (0.690.82). For most joints, MDC were smaller when using all ten trials. Conclusions The reaching task proposed to evaluate the upper limb motor performance was found reliable in people with and without SIS. Furthermore, the minimal difference necessary to infer a meaningful change in motor performance was determined, indicating that relatively small changes in task performance can be interpreted as a change in motor performance. PMID:20331889

  14. Test-retest reliability and agreement of the SPI-Questionnaire to detect symptoms of digital ischemia in elite volleyball players.

    PubMed

    van de Pol, Daan; Zacharian, Tigran; Maas, Mario; Kuijer, P Paul F M

    2017-06-01

    The Shoulder posterior circumflex humeral artery Pathology and digital Ischemia - questionnaire (SPI-Q) has been developed to enable periodic surveillance of elite volleyball players, who are at risk for digital ischemia. Prior to implementation, assessing reliability is mandatory. Therefore, the test-retest reliability and agreement of the SPI-Q were evaluated among the population at risk. A questionnaire survey was performed with a 2-week interval among 65 elite male volleyball players assessing symptoms of cold, pale and blue digits in the dominant hand during or after practice or competition using a 4-point Likert scale (never, sometimes, often and always). Kappa (κ) and percentage of agreement (POA) were calculated for individual symptoms, and to distinguish symptomatic and asymptomatic players. For the individual symptoms, κ ranged from "poor" (0.25) to "good" (0.63), and POA ranged from "moderate" (78%) to "good" (97%). To classify symptomatic players, the SPI-Q showed "good" reliability (κ = 0.83; 95%CI 0.69-0.97) and "good" agreement (POA = 92%). The current study has proven the SPI-Q to be reliable for detecting elite male indoor volleyball players with symptoms of digital ischemia.

  15. Disease Severity and Progression in Progressive Supranuclear Palsy and Multiple System Atrophy: Validation of the NNIPPS – PARKINSON PLUS SCALE

    PubMed Central

    Payan, Christine A. M.; Viallet, François; Landwehrmeyer, Bernhard G.; Bonnet, Anne-Marie; Borg, Michel; Durif, Franck; Lacomblez, Lucette; Bloch, Frédéric; Verny, Marc; Fermanian, Jacques; Agid, Yves; Ludolph, Albert C.

    2011-01-01

    Background The Natural History and Neuroprotection in Parkinson Plus Syndromes (NNIPPS) study was a large phase III randomized placebo-controlled trial of riluzole in Progressive Supranuclear Palsy (PSP, n = 362) and Multiple System Atrophy (MSA, n = 398). To assess disease severity and progression, we constructed and validated a new clinical rating scale as an ancillary study. Methods and Findings Patients were assessed at entry and 6-montly for up to 3 years. Evaluation of the scale's psychometric properties included reliability (n = 116), validity (n = 760), and responsiveness (n = 642). Among the 85 items of the initial scale, factor analysis revealed 83 items contributing to 15 clinically relevant dimensions, including Activity of daily Living/Mobility, Axial bradykinesia, Limb bradykinesia, Rigidity, Oculomotor, Cerebellar, Bulbar/Pseudo-bulbar, Mental, Orthostatic, Urinary, Limb dystonia, Axial dystonia, Pyramidal, Myoclonus and Tremor. All but the Pyramidal dimension demonstrated good internal consistency (Cronbach α≥0.70). Inter-rater reliability was high for the total score (Intra-class coefficient = 0.94) and 9 dimensions (Intra-class coefficient = 0.80–0.93), and moderate (Intra-class coefficient = 0.54–0.77) for 6. Correlations of the total score with other clinical measures of severity were good (rho≥0.70). The total score was significantly and linearly related to survival (p<0.0001). Responsiveness expressed as the Standardized Response Mean was high for the total score slope of change (SRM = 1.10), though higher in PSP (SRM = 1.25) than in MSA (SRM = 1.0), indicating a more rapid progression of PSP. The slope of change was constant with increasing disease severity demonstrating good linearity of the scale throughout disease stages. Although MSA and PSP differed quantitatively on the total score at entry and on rate of progression, the relative contribution of clinical dimensions to overall severity and progression was similar. Conclusions The NNIPPS-PPS has suitable validity, is reliable and sensitive, and therefore is appropriate for use in clinical studies with PSP or MSA. Trial Registration ClinicalTrials.gov NCT00211224 PMID:21829612

  16. Reliability of quantitative EEG (qEEG) measures and LORETA current source density at 30 days.

    PubMed

    Cannon, Rex L; Baldwin, Debora R; Shaw, Tiffany L; Diloreto, Dominic J; Phillips, Sherman M; Scruggs, Annie M; Riehl, Timothy C

    2012-06-14

    There is a growing interest for using quantitative EEG and LORETA current source density in clinical and research settings. Importantly, if these indices are to be employed in clinical settings then the reliability of these measures is of great concern. Neuroguide (Applied Neurosciences) is sophisticated software developed for the analyses of power, and connectivity measures of the EEG as well as LORETA current source density. To date there are relatively few data evaluating topographical EEG reliability contrasts for all 19 channels and no studies have evaluated reliability for LORETA calculations. We obtained 4 min eyes-closed and eyes-opened EEG recordings at 30-day intervals. The EEG was analyzed in Neuroguide and FFT power, coherence and phase was computed for traditional frequency bands (delta, theta, alpha and beta) and LORETA current source density was calculated in 1 Hz increments and summed for total power in eight regions of interest (ROI). In order to obtain a robust measure of reliability we utilized a random effects model with an absolute agreement definition. The results show very good reproducibility for total absolute power and coherence. Phase shows lower reliability coefficients. LORETA current source density shows very good reliability with an average 0.81 for ECB and 0.82 for EOB. Similarly, the eight regions of interest show good to very good agreement across time. Implications for future directions and use of qEEG and LORETA in clinical populations are discussed. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Psychometrics and utility of Psycho-Educational Profile-Revised as a developmental quotient measure among children with the dual disability of intellectual disability and autism.

    PubMed

    Alwinesh, Merlin Thanka Jemi; Joseph, Rachel Beulah Jansirani; Daniel, Anna; Abel, Julie Sandra; Shankar, Satya Raj; Mammen, Priya; Russell, Sushila; Russell, Paul Swamidhas Sudhakar

    2012-09-01

    There is no agreement about the measure to quantify the intellectual/developmental level in children with the dual disability of intellectual disability and autism. Therefore, we studied the psychometric properties and utility of Psycho-Educational Profile-Revised (PEP-R) as a developmental test in this population. We identified 116 children with dual disability from the day care and inpatient database of a specialised Autism Clinic. Scale and domain level scores of PEP-R were collected and analyzed. We examined the internal consistency, domain-total correlation of PEP-R and concurrent validity of PEP-R against Gesell's Developmental Schedule, inter-rater and test-retest reliability and utility of PEP-R among children with dual disability in different ages, functional level and severity of autism. Besides the adequate face and content validity, PEP-R demonstrates a good internal consistency (Cronbach's α ranging from 0.91 to 0.93) and domain-total correlation (ranging from 0.75 to 0.90). The inter-rater reliability (intraclass correlation coefficient, ICC = 0.96) and test-retest reliability (ICC = 0.87) for PEP-R is good. There is moderate-to-high concurrent validity with GDS (r ranging from 0.61 to 0.82; all Ps = 0.001). The utility of PEP-R as a developmental measure was good with infants, toddlers, pre-school and primary school children. The ability of PEP-R to measure the developmental age was good, irrespective of the severity of autism but was better with high-functioning children. The PEP-R as an intellectual/developmental test has strong psychometric properties in children with dual disability. It could be used in children with different age groups and severity of autism. PEP-R should be used with caution as a developmental test in children with dual disability who are low functioning.

  18. Validity and Reliability of a Wearable Inertial Sensor to Measure Velocity and Power in the Back Squat and Bench Press.

    PubMed

    Orange, Samuel T; Metcalfe, James W; Liefeith, Andreas; Marshall, Phil; Madden, Leigh A; Fewster, Connor R; Vince, Rebecca V

    2018-05-08

    Orange, ST, Metcalfe, JW, Liefeith, A, Marshall, P, Madden, LA, Fewster, CR, and Vince, RV. Validity and reliability of a wearable inertial sensor to measure velocity and power in the back squat and bench press. J Strength Cond Res XX(X): 000-000, 2018-This study examined the validity and reliability of a wearable inertial sensor to measure velocity and power in the free-weight back squat and bench press. Twenty-nine youth rugby league players (18 ± 1 years) completed 2 test-retest sessions for the back squat followed by 2 test-retest sessions for the bench press. Repetitions were performed at 20, 40, 60, 80, and 90% of 1 repetition maximum (1RM) with mean velocity, peak velocity, mean power (MP), and peak power (PP) simultaneously measured using an inertial sensor (PUSH) and a linear position transducer (GymAware PowerTool). The PUSH demonstrated good validity (Pearson's product-moment correlation coefficient [r]) and reliability (intraclass correlation coefficient [ICC]) only for measurements of MP (r = 0.91; ICC = 0.83) and PP (r = 0.90; ICC = 0.80) at 20% of 1RM in the back squat. However, it may be more appropriate for athletes to jump off the ground with this load to optimize power output. Further research should therefore evaluate the usability of inertial sensors in the jump squat exercise. In the bench press, good validity and reliability were evident only for the measurement of MP at 40% of 1RM (r = 0.89; ICC = 0.83). The PUSH was unable to provide a valid and reliable estimate of any other criterion variable in either exercise. Practitioners must be cognizant of the measurement error when using inertial sensor technology to quantify velocity and power during resistance training, particularly with loads other than 20% of 1RM in the back squat and 40% of 1RM in the bench press.

  19. Construct validity and reliability of the Finnish version of the Knee Injury and Osteoarthritis Outcome Score.

    PubMed

    Multanen, Juhani; Honkanen, Mikko; Häkkinen, Arja; Kiviranta, Ilkka

    2018-05-22

    The Knee Injury and Osteoarthritis Outcome Score (KOOS) is a commonly used knee assessment and outcome tool in both clinical work and research. However, it has not been formally translated and validated in Finnish. The purpose of this study was to translate and culturally adapt the KOOS questionnaire into Finnish and to determine its validity and reliability among Finnish middle-aged patients with knee injuries. KOOS was translated and culturally adapted from English into Finnish. Subsequently, 59 patients with knee injuries completed the Finnish version of KOOS, Western Ontario and McMaster Osteoarthritis Index (WOMAC), Short-Form 36 Health Survey (SF-36) and Numeric Pain Rating Scale (Pain-NRS). The same KOOS questionnaire was re-administered 2 weeks later. Psychometric assessment of the Finnish KOOS was performed by testing its construct validity and reliability by using internal consistency, test-retest reliability and measurement error. The floor and ceiling effects were also examined. The cross-cultural adaptation revealed only minor cultural differences and was well received by the patients. For construct validity, high to moderate Spearman's Correlation Coefficients were found between the KOOS subscales and the WOMAC, SF-36, and Pain-NRS subscales. The Cronbach's alpha was from 0.79 to 0.96 for all subscales indicating acceptable internal consistency. The test-retest reliability was good to excellent, with Intraclass Correlation Coefficients ranging from 0.73 to 0.86 for all KOOS subscales. The minimal detectable change ranged from 17 to 34 on an individual level and from 2 to 4 on a group level. No floor or ceiling effects were observed. This study yielded an appropriately translated and culturally adapted Finnish version of KOOS which demonstrated good validity and reliability. Our data indicate that the Finnish version of KOOS is suitable for assessment of the knee status of Finnish patients with different knee complaints. Further studies are needed to evaluate the predictive ability of KOOS in the Finnish population.

  20. Tobacco Use Prevention for the Young (TUPY-S): Development, Validity and Reliability of an Interactive Multimedia Strategy from the Adolescents’ Perspective in Malaysia

    PubMed Central

    Zin, Faridah Mohd; Hillaluddin, Azlin Hilma; Mustaffa, Jamaludin

    2017-01-01

    Objective: This study aims to develop, validate and determine the reliability of an interactive multimedia strategy to prevent tobacco use among the young (TUPY-S) from an adolescents’ perspective. Methods: A descriptive study design was utilized. A modular instruction guideline by Russel (1974) was followed in the entire process, comprising a feasibility study, a review of existing modules, specification of the objectives, identification of the construct criterion items, learner analysis and entry behavior specification, establishment of the sequence instruction and media selection, a tryout with students and a field test. Result: Feasibility was agreed among the researchers and the school authorities. Culturally suitable rigorously developed tobacco use preventive strategies delivered using information technology (IT) are lacking in the literature. The objective of TUPY-S is to prevent tobacco use among adolescents living in Malaysia. Identified construct criterion items include knowledge, attitude, intention to use, self-efficacy, and refusal skill. The target population was early adolescents belonging to generation-Z. Content was developed from the adolescents’ perspective and delivered using IT in Malay language. Content validity, assessed by six experts in the field and module development, was good at 86%. The students’ tryout showed satisfactory face validity subjectively and objectively (85.5%) and high alpha Cronbach reliability (0.91). Conclusion: TUPY-S was confirmed to suit early adolescents of the current generation living in Malaysia. It demonstrated good content validity among the experts, satisfactory face validity and reliability among the target population. TUPY-S is ready to be evaluated for its effectiveness among early adolescents. PMID:28612599

  1. A Chinese version of the Psychotic Symptom Rating Scales: psychometric properties in recent-onset and chronic psychosis.

    PubMed

    Chien, Wai-Tong; Lee, Isabella Yuet-Ming; Wang, Li-Qun

    2017-01-01

    The purpose of this study was to test the reliability, validity, and factor structure of a Chinese version of the Psychotic Symptom Rating Scale (PSYRATS) in 198 and 202 adult patients with recent-onset and chronic psychosis, respectively. The PSYRATS has been translated into different language versions and has been validated for clinical and research use mainly in chronic psychotic patients but not in recent-onset psychosis patients or in Chinese populations. The psychometric analysis of the translated Chinese version included assessment of its content validity, semantic equivalence, interrater and test-retest reliability, reproducibility, sensitivity to changes in psychotic symptoms, internal consistency, concurrent validity (compared to a valid psychotic symptom scale), and factor structure. The Chinese version demonstrated very satisfactory content validity as rated by an expert panel, good semantic equivalence with the original version, and high interrater and test-retest (at 2-week interval) reliability. It also indicated very good reproducibility of and sensitivity to changes in psychotic symptoms in line with the symptom severity measured with the Positive and Negative Syndrome Scale (PANSS). The scale consisted of four factors for the hallucination subscale and two factors for the delusion subscale, explaining about 80% of the total variance of the construct, indicating satisfactory correlations between the hallucination and delusion factors themselves, between items, factors, subscales, and overall scale, and between factors and relevant item and subscale scores of the PANSS. The Chinese version of the PSYRATS is a reliable and valid instrument to measure symptom severity in Chinese psychotic patients complementary to other existing measures mainly in English language.

  2. FIMA, the questionnaire for health-related resource use in the elderly population: validity, reliability, and usage of the Polish version in clinical practice.

    PubMed

    Mazurek, Justyna; Sutkowska, Edyta; Szcześniak, Dorota; Urbańska, Katarzyna Małgorzata; Rymaszewska, Joanna

    2018-01-01

    The purpose of this study was to determine the validity and reliability of the Polish version of the Questionnaire for Health-Related Resource Use in an Elderly Population [Fragebogen zur Inanspruchnahme medizinischer und nicht-medizinischer Versorgungsleistungen im Alter (FIMA)]. This was a cross-sectional study conducted in a rehabilitation care unit in Poland between January and June of 2017. Sixty-one patients aged ≥65 years who had been admitted to the unit were enrolled into the study. Each participant was evaluated twice: once within 48 hours of admission (T1) and once after 2 weeks (T2). The translated instrument was understood by most respondents in a selected population and it maintained a reading and comprehension level that was accessible by most respondents, even of a low education level. With the aid of the prevalence-adjusted bias-adjusted kappa (PABAK) and intraclass correlation coefficient (ICC), 100% test-retest reliability for 10 out of the 12 questions that were subjected to analysis was indicated. The most frequent health-related resource uses were appointments at the general practitioner (90.2%) and orthopedist (54.1%), medication (93.4%), and the necessity to have glasses as supportive equipment (70.5%). The Polish FIMA demonstrated very good test-retest reliability, good validity, and ease of use for elderly people. Further investigation is required. In the future, the routine use of this instrument could be encouraged to assess the use and demand for medical and nonmedical services among the elderly.

  3. Measuring the Performance of Attention Networks with the Dalhousie Computerized Attention Battery (DalCAB): Methodology and Reliability in Healthy Adults.

    PubMed

    Jones, Stephanie A H; Butler, Beverly C; Kintzel, Franziska; Johnson, Anne; Klein, Raymond M; Eskes, Gail A

    2016-01-01

    Attention is an important, multifaceted cognitive domain that has been linked to three distinct, yet interacting, networks: alerting, orienting, and executive control. The measurement of attention and deficits of attention within these networks is critical to the assessment of many neurological and psychiatric conditions in both research and clinical settings. The Dalhousie Computerized Attention Battery (DalCAB) was created to assess attentional functions related to the three attention networks using a range of tasks including: simple reaction time, go/no-go, choice reaction time, dual task, flanker, item and location working memory, and visual search. The current study provides preliminary normative data, test-retest reliability (intraclass correlations) and practice effects in DalCAB performance 24-h after baseline for healthy young adults (n = 96, 18-31 years). Performance on the DalCAB tasks demonstrated Good to Very Good test-retest reliability for mean reaction time, while accuracy and difference measures (e.g., switch costs, interference effects, and working memory load effects) were most reliable for tasks that require more extensive cognitive processing (e.g., choice reaction time, flanker, dual task, and conjunction search). Practice effects were common and pronounced at the 24-h interval. In addition, performance related to specific within-task parameters of the DalCAB sub-tests provides preliminary support for future formal assessment of the convergent validity of our interpretation of the DalCAB as a potential clinical and research assessment tool for measuring aspects of attention related to the alerting, orienting, and executive control networks.

  4. Preliminary appraisal of the reliability and validity of the Colorado State University Feline Acute Pain Scale.

    PubMed

    Shipley, Hilary; Guedes, Alonso; Graham, Lynelle; Goudie-DeAngelis, Elizabeth; Wendt-Hornickle, Erin

    2018-05-01

    Objectives The objective of this study was to determine the inter-rater reliability and convergent validity of the Colorado State University Feline Acute Pain Scale (CSU-FAPS) in a preliminary appraisal of its performance in a clinical teaching setting. Methods Sixty-eight female cats were assessed for pain after ovariohysterectomy. A cohort of 21 cats was examined independently by four raters (two board-certified anesthesiologists and two anesthesia residents) with the CSU-FAPS, and intra-class correlation coefficient (ICC) was used to determine inter-rater reliability. Weighted Cohen's kappa was used to determine inter-rater reliability centered on the 'need to reassess analgesic plan' (dichotomous scale). A separate cohort of 47 cats was evaluated independently by two raters (one board-certified anesthesiologist and one veterinary small animal rotating intern) using the CSU-FAPS and the Glasgow Composite Measure Pain Scale (CMPS-Feline), and Spearman rank-order correlation was determined to assess convergent validity. Reliability was interpreted using Altman's classification as very good, good, moderate, fair and poor. Validity was considered adequate if correlation coefficients were between 0.4 and 0.8. Results The ICC was 0.61 for anesthesiologists and 0.67 for residents, indicating good reliability. Weighted Cohen's kappa was 0.79 for anesthesiologists and 0.44 for residents, indicating moderate to good reliability. The Spearman rank correlation indicated a statistically significant ( P = 0.0003) positive correlation (0.31; 95% confidence interval 0.14-0.46) between the CSU-FAPS and the CMPS-Feline. Conclusions and relevance The CSU-FAPS showed moderate-to-good inter-rater reliability when used by veterinarians to assess pain level or need to reassess analgesic plan after ovariohysterectomy in cats. The validity fell short of current guidelines for correlation coefficients and further refinement and testing are warranted to improve its performance.

  5. Ultrasound measurement apparatus for liquids characterization

    NASA Astrophysics Data System (ADS)

    Vieira, R. C.; Costa-Felix, R. P. B.

    2018-03-01

    The present paper discloses the validation of an experimental ultrasound apparatus and method for liquids characterization. The research aims to stablish a simple, reliable, accurate and portable way to identify contaminants in hydrocarbon substances, such as adulteration in gasoline. The results depicted so far demonstrated a general uncertainty of speed of sound assessment less than 10 m s-1, and distance accuracy of less than 1%. Those figures are good enough for an in-site device to evaluate possible contamination of fuels or other liquids.

  6. Cross-cultural evaluation of the French version of the LEIPAD, a health-related quality of life instrument for use in the elderly living at home.

    PubMed

    Jalenques, I; Auclair, C; Roblin, J; Morand, D; Tourtauchaux, R; May, R; Vaille-Perret, E; Watts, J; Gerbaud, L; De Leo, D

    2013-04-01

    To cross-culturally adapt a French version of the LEIPAD, a self-administered questionnaire assessing the health-related quality of life (HRQoL) in adults aged 65 years and over living at home, and to evaluate its psychometric properties. After having translated LEIPAD in accordance with guidelines, we studied psychometric properties: reliability and construct validity-factor analysis, relationships between items and scales, internal consistency, concurrent validity with the Medical Outcome Study Short-Form 36 and known-groups validity. The results obtained in a sample of 195 elderly from the general population showed very good acceptability, with response rates superior to 93 %. Exploratory factor analysis extracted eight factors providing a multidimensionality structure with five misclassifications of items in the seven theoretical scales. Good internal consistency (Cronbach's alpha ranging from 0.73 and 0.86) and strong test-retest reliability (ICCs higher than 0.80 for six scales and 0.70 for one) were demonstrated. Concurrent validity with the SF-36 showed small to strong expected correlations. This first evaluation of the French version of LEIPAD's psychometric properties provides evidence in construct validity and reliability. It would allow HRQoL assessment in clinical and common practice, and investigators would be able to take part in national and international research projects.

  7. Development and validation of the Chinese version of dry eye related quality of life scale.

    PubMed

    Zheng, Bang; Liu, Xiao-Jing; Sun, Yue-Qian Fiona; Su, Jia-Zeng; Zhao, Yang; Xie, Zheng; Yu, Guang-Yan

    2017-07-17

    To develop the Chinese version of quality of life scale for dry eye patients based on the Impact of Dry Eye on Everyday Life (IDEEL) questionnaire and to assess the reliability and validity of the developed scale. The original IDEEL was adapted cross-culturally to Chinese language and further developed following standard procedures. A total of 100 Chinese patients diagnosed with dry eye syndrome were included to investigate the psychometric properties of the Chinese version of scale. Psychometric tests included internal consistency (Cronbach's ɑ coefficients), construct validity (exploratory factor analysis), and known-groups validity (the analysis of variance). The Chinese version of Dry Eye Related Quality of Life (CDERQOL) Scale contains 45 items classified into 5 domains. Good to excellent internal consistency reliability was demonstrated for all 5 domains (Cronbach's ɑ coefficients range from 0.716 to 0.913). Construct validity assessment indicated a consistent factorial structure of the CDERQOL scale with hypothesized construct, with the exception of "Dry Eye Symptom-Bother" domain. All domain scores were detected with significant difference across three severity groups of dry eye patients (P < 0.05) except for "Satisfaction with Treatment" domain, indicating good known-groups validity. The results indicated that the CDERQOL scale is a reliable and valid instrument for patients with dry eye syndrome among Chinese population, and could be used as a supplementary diagnostic and treatment-effectiveness measure.

  8. Psychometric Properties of the Sexual Excitation/Sexual Inhibition Inventory for Women in a German Sample.

    PubMed

    Velten, Julia; Scholten, Saskia; Graham, Cynthia A; Margraf, Jürgen

    2016-02-01

    The Sexual Excitation Sexual/Inhibition Inventory for Women (SESII-W) is a self-report questionnaire for assessing propensities of sexual excitation (SE) and sexual inhibition (SI) in women. According to the dual control model of sexual response, these two factors differ between individuals and influence the occurrence of sexual arousal in given situations. Extreme levels of SE and SI are postulated to be associated with sexual problems or risky sexual behaviors. Psychometric evaluation of the original scale yielded two higher order and eight lower order factors as well as satisfactory to good construct validity and reliability. The present study was designed to assess the psychometric properties of a German version of the SESII-W utilizing a large convenience sample of 2206 women. Confirmatory factor analysis showed a satisfactory overall model fit, with support for the five lower order factors of SE (Arousability, Sexual Power Dynamics, Smell, Partner Characteristics, Setting) and the three lower order factors of SI (Relationship Importance, Arousal Contingency, and Concerns about Sexual Function). Additionally, the scale demonstrated good convergent and discriminant validity, internal consistency, and test-retest-reliability. The German SESII-W is a sufficiently reliable and valid measure for assessing SE and SI in women. Hence, its use can be recommended for future research in Germany that investigates women's sexual behaviors and experiences.

  9. Development of the Assessment of Belief Conflict in Relationship-14 (ABCR-14).

    PubMed

    Kyougoku, Makoto; Teraoka, Mutsumi; Masuda, Noriko; Ooura, Mariko; Abe, Yasushi

    2015-01-01

    Nurses and other healthcare workers frequently experience belief conflict, one of the most important, new stress-related problems in both academic and clinical fields. In this study, using a sample of 1,683 nursing practitioners, we developed The Assessment of Belief Conflict in Relationship-14 (ABCR-14), a new scale that assesses belief conflict in the healthcare field. Standard psychometric procedures were used to develop and test the scale, including a qualitative framework concept and item-pool development, item reduction, and scale development. We analyzed the psychometric properties of ABCR-14 according to entropy, polyserial correlation coefficient, exploratory factor analysis, confirmatory factor analysis, average variance extracted, Cronbach's alpha, Pearson product-moment correlation coefficient, and multidimensional item response theory (MIRT). The results of the analysis supported a three-factor model consisting of 14 items. The validity and reliability of ABCR-14 was suggested by evidence from high construct validity, structural validity, hypothesis testing, internal consistency reliability, and concurrent validity. The result of the MIRT offered strong support for good item response of item slope parameters and difficulty parameters. However, the ABCR-14 Likert scale might need to be explored from the MIRT point of view. Yet, as mentioned above, there is sufficient evidence to support that ABCR-14 has high validity and reliability. The ABCR-14 demonstrates good psychometric properties for nursing belief conflict. Further studies are recommended to confirm its application in clinical practice.

  10. Validity and cultural equivalence of the standard Greene Climacteric Scale in Hong Kong.

    PubMed

    Chen, Run Qiu; Davis, Susan R; Wong, Chit Ming; Lam, Tai Hing

    2010-01-01

    The aim of this study was to translate the standard Greene Climacteric Scale (GCS) and a urogenital symptom scale into colloquial Chinese (Hong Kong) and test their validity and reliability in Hong Kong Chinese women. The scales were translated with standard techniques, and cross-cultural construct validity, internal consistency, test-retest reliability, and responsiveness were tested on samples of women aged 40 to 60 years recruited from the community. A total of 611 women, with mean (SD) age of 48.9 (5.3) years, provided completed scales for the study. Confirmatory factor analysis demonstrated construct validity of the translated standard GCS. The items were found to have good homogeneity in measuring the scale concepts (Cronbach alpha > 0.7). But the three-item urogenital scale had poor internal consistency (Cronbach alpha = 0.43), and a combination of this scale with the standard GCS resulted in a reduced model fit to the data. Test-retest reliability for the GCS was good on women recruited for a retest (n = 52). The translated GCS was found to be responsive to change over time (effect size, 0.59; n = 19). The Chinese (Hong Kong) version of the standard GCS is a valid and cultural-equivalent instrument. Our data do not support inclusion of the urogenital scale to the standard GCS. Measurement of urogenital symptoms is subject to further study.

  11. Day to Day Variability and Reliability of Blood Oxidative Stress Markers within a Four-Week Period in Healthy Young Men.

    PubMed

    Goldfarb, A H; Garten, R S; Waller, J; Labban, J D

    2014-01-01

    The present study aimed to determine the day to day variability and reliability of several blood oxidative stress markers at rest in a healthy young cohort over a four-week period. Twelve apparently healthy resistance trained males (24.6 ± 3.0 yrs) were tested over 7 visits within 4 weeks with at least 72 hrs between visits at the same time of day. Subjects rested 30 minutes prior to blood being obtained by vacutainer. Results. The highest IntraClass correlations (ICC's) were obtained for protein carbonyls (PC) and oxygen radical absorbance capacity (ORAC) (PC = 0.785 and ORAC = 0.780). Cronbach's α reliability score for PC was 0.967 and for ORAC was 0.961. The ICC's for GSH, GSSG, and the GSSG/TGH ratio ICC were 0.600, 0.573, and 0.570, respectively, with Cronbach's α being 0.913, 0.904, and 0.903, respectively. Xanthine oxidase ICC was 0.163 and Cronbach's α was 0.538. Conclusions. PC and ORAC demonstrated good to excellent reliability while glutathione factors had poor to excellent reliability. Xanthine oxidase showed poor reliability and high variability. These results suggest that the PC and ORAC markers were the most stable and reliable oxidative stress markers in blood and that daily changes across visits should be considered when interpreting resting blood oxidative stress markers.

  12. Parental Understanding of Infant Health Information: Health Literacy, Numeracy and the Parental Health Literacy Activities Test (PHLAT)

    PubMed Central

    Kumar, Disha; Sanders, Lee; Perrin, Eliana M.; Lokker, Nicole; Patterson, Baron; Gunn, Veronica; Finkle, Joanne; Franco, Vivian; Choi, Leena; Rothman, Russell L.

    2010-01-01

    Objective To assess parental health literacy and numeracy skills in understanding instructions for caring for young children, and to develop and validate a new parental health literacy scale, the Parental Health Literacy Activities Test (PHLAT). Methods Caregivers of infants (age <13 months) were recruited in a cross-sectional study at pediatric clinics at three academic medical centers. Literacy and numeracy skills were assessed with previously validated instruments. Parental health literacy was assessed with the new 20-item PHLAT. Psychometric analyses were performed to assess item characteristics and to generate a shortened, 10-item version (PHLAT-10). Results 182 caregivers were recruited. While 99% had adequate literacy skills, only 17% had >9th-grade numeracy skills. Mean score on the PHLAT was 68% (SD 18); for example, only 47% of caregivers could correctly describe how to mix infant formula from concentrate, and only 69% could interpret a digital thermometer to determine if an infant had a fever. Higher performance on the PHLAT was significantly correlated (p<0.001) with education, literacy skill, and numeracy level (r=0.29, 0.38, and 0.55 respectively). Caregivers with higher PHLAT scores were also more likely to interpret age recommendations for cold medications correctly (OR 1.6, 95% CI 1.02, 2.6). Internal reliability on the PHLAT was good (KR-20=0.76). The PHLAT-10 also demonstrated good validity and reliability. Conclusions Many parents do not understand common health information required to care for their infants. The PHLAT, and PHLAT-10 have good reliability and validity and may be useful tools for identifying parents who need better communication of health-related instructions. PMID:20674532

  13. Angels and demons are among us: assessing individual differences in belief in pure evil and belief in pure good.

    PubMed

    Webster, Russell J; Saucier, Donald A

    2013-11-01

    We conducted five studies to demonstrate that individuals' beliefs in pure evil (BPE) and in pure good (BPG) are valid and important psychological constructs. First, these studies together demonstrated that BPE and BPG are reliable, unitary, and stable constructs each composed of eight theoretically interdependent dimensions. Second, these studies showed that across a wide variety of different measures, higher BPE consistently related to greater intergroup aggression (e.g., supporting the death penalty and preemptive military aggression) and less intergroup prosociality (e.g., opposing criminal rehabilitation, proracial policies, and beneficial social programs), while higher BPG consistently related to less intergroup aggression (e.g., opposing proviolent foreign relations and torture) and greater intergroup prosociality (e.g., supporting criminal rehabilitation and support for diplomacy). In sum, these studies evidence that BPE and BPG relate to aggressive and prosocial orientations toward others and have strong potential to advance current theories on prejudice, aggression, and prosociality.

  14. Large area optical mapping of surface contact angle.

    PubMed

    Dutra, Guilherme; Canning, John; Padden, Whayne; Martelli, Cicero; Dligatch, Svetlana

    2017-09-04

    Top-down contact angle measurements have been validated and confirmed to be as good if not more reliable than side-based measurements. A range of samples, including industrially relevant materials for roofing and printing, has been compared. Using the top-down approach, mapping in both 1-D and 2-D has been demonstrated. The method was applied to study the change in contact angle as a function of change in silver (Ag) nanoparticle size controlled by thermal evaporation. Large area mapping reveals good uniformity for commercial Aspen paper coated with black laser printer ink. A demonstration of the forensic and chemical analysis potential in 2-D is shown by uncovering the hidden CsF initials made with mineral oil on the coated Aspen paper. The method promises to revolutionize nanoscale characterization and industrial monitoring as well as chemical analyses by allowing rapid contact angle measurements over large areas or large numbers of samples in ways and times that have not been possible before.

  15. Preliminary validation and reliability of the Short Form Chronic Respiratory Disease Questionnaire in a lung cancer population.

    PubMed

    Charalambous, A; Molassiotis, A

    2017-01-01

    The Short Form Chronic Respiratory Questionnaire (SF-CRQ) is frequently used in patients with obstructive pulmonary disease and it has demonstrated excellent psychometric properties. Since there is no psychometric information for its use with lung cancer patients, this study explored its validity and reliability in this population. Forty-six patients were assessed at two time points (with a 4-week interval) using the SF-CRQ, the modified Borg Scale, five numerical rating scales related to Perceived Severity of Breathlessness, and the Hospital Anxiety and Depression Scale. Internal consistency reliability was investigated by Cronbach's alpha reliability coefficient, test-retest reliability by Spearman-Brown reliability coefficient (P), content validity as well as convergent validity by Pearson's correlation coefficient between the SF-CRQ, and the conceptual similar scales mentioned above were explored. A principal component factor analysis was performed. The internal consistency was high [α = 0.88 (baseline) and 0.91 (after 1 month)]. The SF-CRQ had good stability with test-retest reliability ranging from r = 0.64 to 0.78, P < 0.001. Factor analysis suggests a single construct in this population. The preliminary data analyses supported the convergent, content, and construct validity of the SF-CRQ providing promising evidence that this can be a valid and reliable instrument for the assessment of quality of life related to breathlessness in lung cancer patients. © 2015 John Wiley & Sons Ltd.

  16. Development and evaluation of an instrument for assessing brief behavioral change interventions.

    PubMed

    Strayer, Scott M; Martindale, James R; Pelletier, Sandra L; Rais, Salehin; Powell, Jon; Schorling, John B

    2011-04-01

    To develop an observational coding instrument for evaluating the fidelity and quality of brief behavioral change interventions based on the behavioral theories of the 5 A's, Stages of Change and Motivational Interviewing. Content and face validity were assessed prior to an intervention where psychometric properties were evaluated with a prospective cohort of 116 medical students. Properties assessed included the inter-rater reliability of the instrument, internal consistency of the full scale and sub-scales and descriptive statistics of the instrument. Construct validity was assessed based on student's scores. Inter-rater reliability for the instrument was 0.82 (intraclass correlation). Internal consistency for the full scale was 0.70 (KR20). Internal consistencies for the sub-scales were as follows: MI intervention component (KR20=.7); stage-appropriate MI-based intervention (KR20=.55); MI spirit (KR20=.5); appropriate assessment (KR20=.45) and appropriate assisting (KR20=.56). The instrument demonstrated good inter-rater reliability and moderate overall internal consistency when used to assess performing brief behavioral change interventions by medical students. This practical instrument can be used with minimal training and demonstrates promising psychometric properties when evaluated with medical students counseling standardized patients. Further testing is required to evaluate its usefulness in clinical settings. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  17. Development and validation of the Survey of Organizational Research Climate (SORC).

    PubMed

    Martinson, Brian C; Thrush, Carol R; Lauren Crain, A

    2013-09-01

    Development and targeting efforts by academic organizations to effectively promote research integrity can be enhanced if they are able to collect reliable data to benchmark baseline conditions, to assess areas needing improvement, and to subsequently assess the impact of specific initiatives. To date, no standardized and validated tool has existed to serve this need. A web- and mail-based survey was administered in the second half of 2009 to 2,837 randomly selected biomedical and social science faculty and postdoctoral fellows at 40 academic health centers in top-tier research universities in the United States. Measures included the Survey of Organizational Research Climate (SORC) as well as measures of perceptions of organizational justice. Exploratory and confirmatory factor analyses yielded seven subscales of organizational research climate, all of which demonstrated acceptable internal consistency (Cronbach's α ranging from 0.81 to 0.87) and adequate test-retest reliability (Pearson r ranging from 0.72 to 0.83). A broad range of correlations between the seven subscales and five measures of organizational justice (unadjusted regression coefficients ranging from 0.13 to 0.95) document both construct and discriminant validity of the instrument. The SORC demonstrates good internal (alpha) and external reliability (test-retest) as well as both construct and discriminant validity.

  18. Validation of the Spanish Addiction Severity Index Multimedia Version (S-ASI-MV).

    PubMed

    Butler, Stephen F; Redondo, José Pedro; Fernandez, Kathrine C; Villapiano, Albert

    2009-01-01

    This study aimed to develop and test the reliability and validity of a Spanish adaptation of the ASI-MV, a computer administered version of the Addiction Severity Index, called the S-ASI-MV. Participants were 185 native Spanish-speaking adult clients from substance abuse treatment facilities serving Spanish-speaking clients in Florida, New Mexico, California, and Puerto Rico. Participants were administered the S-ASI-MV as well as Spanish versions of the general health subscale of the SF-36, the work and family unit subscales of the Social Adjustment Scale Self-Report, the Michigan Alcohol Screening Test, the alcohol and drug subscales of the Personality Assessment Inventory, and the Hopkins Symptom Checklist-90. Three-to-five-day test-retest reliability was examined along with criterion validity, convergent/discriminant validity, and factorial validity. Measurement invariance between the English and Spanish versions of the ASI-MV was also examined. The S-ASI-MV demonstrated good test-retest reliability (ICCs for composite scores between .59 and .93), criterion validity (rs for composite scores between .66 and .87), and convergent/discriminant validity. Factorial validity and measurement invariance were demonstrated. These results compared favorably with those reported for the original interviewer version of the ASI and the English version of the ASI-MV.

  19. Development and evaluation of oral Cancer quality-of-life questionnaire (QOL-OC).

    PubMed

    Nie, Min; Liu, Chang; Pan, Yi-Chen; Jiang, Chen-Xi; Li, Bao-Ru; Yu, Xi-Jie; Wu, Xin-Yu; Zheng, Shu-Ning

    2018-05-03

    In this study scales and items for the Oral Cancer Quality-of-life Questionnaire (QOL-OC) were designed and the instrument was evaluated. The QOL-OC was developed and modified using the international definition of quality of life (QOL) promulgated by the European Organization for Research and Treatment of Cancer (EORTC) and analysis of the precedent measuring instruments. The contents of each item were determined in the context of the specific characteristics of oral cancer. Two hundred thirteen oral cancer patients were asked to complete both the EORTC core quality of life questionnaire (EORTC QLC-C30) and the QOL-OC. Data collected was used to conduct factor analysis, test-retest reliability, internal consistency, and construct validity. Questionnaire compliance was relatively high. Fourteen of the 213 subjects accepted the same tests after 24 to 48 h demonstrating a high test-retest reliability for all five scales. Overall internal consistency surpasses 0.8. The outcome of the factor analysis coincides substantially with our theoretical conception. Each item shows a higher correlation coefficient within its own scale than the others which indicates high construct validity. QOL-OC demonstrates fairly good statistical reliability, validity, and feasibility. However, further tests and modification are needed to ensure its applicability to the quality-of-life assessment of Chinese oral cancer patients.

  20. Development and Validation of the Survey of Organizational Research Climate (SORC)

    PubMed Central

    Martinson, Brian C.; Thrush, Carol R.; Crain, A. Lauren

    2012-01-01

    Background Development and targeting efforts by academic organizations to effectively promote research integrity can be enhanced if they are able to collect reliable data to benchmark baseline conditions, to assess areas needing improvement, and to subsequently assess the impact of specific initiatives. To date, no standardized and validated tool has existed to serve this need. Methods A web- and mail-based survey was administered in the second half of 2009 to 2,837 randomly selected biomedical and social science faculty and postdoctoral fellows at 40 academic health centers in top-tier research universities in the United States. Measures included the Survey of Organizational Research Climate (SORC) as well as measures of perceptions of organizational justice. Results Exploratory and confirmatory factor analyses yielded seven subscales of organizational research climate, all of which demonstrated acceptable internal consistency (Cronbach’s α ranging from 0.81 to 0.87) and adequate test-retest reliability (Pearson r ranging from 0.72 to 0.83). A broad range of correlations between the seven subscales and five measures of organizational justice (unadjusted regression coefficients ranging from .13 to .95) document both construct and discriminant validity of the instrument. Conclusions The SORC demonstrates good internal (alpha) and external reliability (test-retest) as well as both construct and discriminant validity. PMID:23096775

  1. The Computerized Perceptual Motor Skills Assessment: A new visual perceptual motor skills evaluation tool for children in early elementary grades.

    PubMed

    Howe, Tsu-Hsin; Chen, Hao-Ling; Lee, Candy Chieh; Chen, Ying-Dar; Wang, Tien-Ni

    2017-10-01

    Visual perceptual motor skills have been proposed as underlying courses of handwriting difficulties. However, there is no evaluation tool currently available to assess these skills comprehensively and to serve as a sensitive measure. The purpose of this study was to validate the Computerized Perceptual Motor Skills Assessment (CPMSA), a newly developed evaluation tool for children in early elementary grades. Its test-retest reliability, concurrent validity, discriminant validity, and responsiveness were examined in 43 typically developing children and 26 children with handwriting difficulty. The CPMSA demonstrated excellent reliability across all subtests with intra-class correlation coefficients (ICCs)≥0.80. Significant moderate correlations between the domains of the CPMSA and corresponding gold standards including Beery VMI, the TVPS-3, and the eye-hand coordination subtest of the DTVP-2 demonstrated good concurrent validity. In addition, the CPMSA showed evidence of discriminant validity in samples of children with and without handwriting difficulty. This article provides evidence in support of the CPMSA. The CPMSA is a reliable, valid, and promising measure of visual perceptual motor skills for children in early elementary grades. Directions for future study and improvements to the assessment are discussed. Copyright © 2017. Published by Elsevier Ltd.

  2. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    PubMed Central

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.

  3. Improved switching reliability achieved in HfOx based RRAM with mountain-like surface-graphited carbon layer

    NASA Astrophysics Data System (ADS)

    Tao, Ye; Ding, Wentao; Wang, Zhongqiang; Xu, Haiyang; Zhao, Xiaoning; Li, Xuhong; Liu, Weizhen; Ma, Jiangang; Liu, Yichun

    2018-05-01

    In this work, we demonstrated an effective method to improve the switching reliability of HfOx based RRAM device by inserting mountain-like surface-graphited carbon (MSGC) layer. The MSGC layer was fabricated through thermal annealing of amorphous carbon (a-C) film with high sp2 proportion (49.7%) under 500 °C on Pt substrate, whose characteristics were validated by XPS and Raman spectrums. The local electric-field (LEF) was enhanced around the nanoscale tips of MSGC layer due to large surface curvature, which leads to simplified CFs and localization of resistive switching region. It takes responsibility to the reduction of high/low resistance states (HRS/LRS) fluctuation from 173.8%/64.9% to 23.6%/6.5%, respectively. In addition, the resulting RRAM devices exhibited fast switching speed (<65 ns), good retention (>104 s at 85 °C) and low cycling degradation. This method could be promising to develop reliable and repeatable high-performance RRAM for practical applications.

  4. Benchmarking Treatment Response in Tourette's Disorder: A Psychometric Evaluation and Signal Detection Analysis of the Parent Tic Questionnaire.

    PubMed

    Ricketts, Emily J; McGuire, Joseph F; Chang, Susanna; Bose, Deepika; Rasch, Madeline M; Woods, Douglas W; Specht, Matthew W; Walkup, John T; Scahill, Lawrence; Wilhelm, Sabine; Peterson, Alan L; Piacentini, John

    2018-01-01

    This study assessed the psychometric properties of a parent-reported tic severity measure, the Parent Tic Questionnaire (PTQ), and used the scale to establish guidelines for delineating clinically significant tic treatment response. Participants were 126 children ages 9 to 17 who participated in a randomized controlled trial of Comprehensive Behavioral Intervention for Tics (CBIT). Tic severity was assessed using the Yale Global Tic Severity Scale (YGTSS), Hopkins Motor/Vocal Tic Scale (HMVTS) and PTQ; positive treatment response was defined by a score of 1 (very much improved) or 2 (much improved) on the Clinical Global Impressions - Improvement (CGI-I) scale. Cronbach's alpha and intraclass correlations (ICC) assessed internal consistency and test-retest reliability, with correlations evaluating validity. Receiver- and Quality-Receiver Operating Characteristic analyses assessed the efficiency of percent and raw-reduction cutoffs associated with positive treatment response. The PTQ demonstrated good internal consistency (α = 0.80 to 0.86), excellent test-retest reliability (ICC = .84 to .89), good convergent validity with the YGTSS and HM/VTS, and good discriminant validity from hyperactive, obsessive-compulsive, and externalizing (i.e., aggression and rule-breaking) symptoms. A 55% reduction and 10-point decrease in PTQ Total score were optimal for defining positive treatment response. Findings help standardize tic assessment and provide clinicians with greater clarity in determining clinically meaningful tic symptom change during treatment. Copyright © 2017. Published by Elsevier Ltd.

  5. Translation and Validation of the Korean Version of the International Knee Documentation Committee Subjective Knee Form

    PubMed Central

    Kim, Jin Goo; Lee, Joong Yub; Seo, Seung Suk; Choi, Choong Hyeok; Lee, Myung Chul

    2013-01-01

    Purpose To perform a cross-cultural adaptation and to test the measurement properties of the Korean version of International Knee Documentation Committee (K-IKDC) Subjective Knee Form. Materials and Methods According to the guidelines for cross-cultural adaptation, translation and backward translation of the English version of the IKDC Subjective Knee Form were performed. After translation into the Korean version, 150 patients who had knee-related problems were asked to complete the K-IKDC, Lysholm score, and Short Form-36 (SF-36). Of these patients, 126 were retested 2 weeks later to evaluate test-retest reliability, and 104 were recruited 3 months later to evaluate responsiveness. Construct validity was analyzed by investigating the correlation with Lysholm score and SF-36; content validity was also evaluated. Standardized mean response was calculated for evaluating responsiveness. Results The test-retest reliability proved excellent with a high value for the intraclass correlation coefficient (r=0.94). The internal consistency was strong (Cronbach's α=0.91). Good content validity with absence of floor not ceiling effects and good convergent and divergent validity were observed. Moderate responsiveness was shown (standardized mean response=0.689). Conclusions The K-IKDC demonstrated good measurement properties. We suggest that this instrument is an excellent evaluation instrument that can be used for Korean patients with knee-related injuries. PMID:24032098

  6. Validity and reliability of Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments in Osteoarthritis

    PubMed Central

    Broderick, Joan E.; Schneider, Stefan; Junghaenel, Doerte U.; Schwartz, Joseph E.; Stone, Arthur A.

    2013-01-01

    Objective Evaluation of known group validity, ecological validity, and test-retest reliability of four domain instruments from the Patient Reported Outcomes Measurement System (PROMIS) in osteoarthritis (OA) patients. Methods Recruitment of an osteoarthritis sample and a comparison general population (GP) through an Internet survey panel. Pain intensity, pain interference, physical functioning, and fatigue were assessed for 4 consecutive weeks with PROMIS short forms on a daily basis and compared with same-domain Computer Adaptive Test (CAT) instruments that use a 7-day recall. Known group validity (comparison of OA and GP), ecological validity (comparison of aggregated daily measures with CATs), and test-retest reliability were evaluated. Results The recruited samples matched (age, sex, race, ethnicity) the demographic characteristics of the U.S. sample for arthritis and the 2009 Census for the GP. Compliance with repeated measurements was excellent: > 95%. Known group validity for CATs was demonstrated with large effect sizes (pain intensity: 1.42, pain interference: 1.25, and fatigue: .85). Ecological validity was also established through high correlations between aggregated daily measures and weekly CATs (≥ .86). Test-retest validity (7-day) was very good (≥ .80). Conclusion PROMIS CAT instruments demonstrated known group and ecological validity in a comparison of osteoarthritis patients with a general population sample. Adequate test-retest reliability was also observed. These data provide encouraging initial data on the utility of these PROMIS instruments for clinical and research outcomes in osteoarthritis patients. PMID:23592494

  7. Low-voltage high-reliability MEMS switch for millimeter wave 5G applications

    NASA Astrophysics Data System (ADS)

    Shekhar, Sudhanshu; Vinoy, K. J.; Ananthasuresh, G. K.

    2018-07-01

    Lack of reliability of radio-frequency microelectromechanical systems (RF MEMS) switches has inhibited their commercial success. Dielectric stiction/breakdown and mechanical shock due to high actuation voltage are common impediments in capacitive MEMS switches. In this work, we report low-actuation voltage RF MEMS switch and its reliability test. Experimental characterization of fabricated devices demonstrate that proposed MEMS switch topology needs very low voltage (4.8 V) for actuation. The mechanical resonant frequency, f 0, quality factor, Q, and switching time are measured to be 8.35 kHz, 1.2, and 33 microsecond, respectively. These MEMS switches have high reliability in terms of switching cycles. Measurements are performed using pulse waveform of magnitude of 6 V under hot-switching condition. Temperature measurement results confirm that the reported switch topology has good thermal stability. The robustness in terms of the measured pull-in voltage shows a variation of 0.08 V °C‑1. Lifetime measurement results after 10 million switching cycles demonstrate insignificant change in the RF performance without any failure. Experimental results show that low voltage improves the lifetime. Low insertion loss (less than 0.6 dB) and improved isolation (above 40 dB) in the frequency range up to 60 GHz have been reported. Measured RF characteristics in the frequency range from 10 MHz to 60 GHz support that these MEMS switches are favorable choice for mm-wave 5G applications.

  8. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry--BREALD-30.

    PubMed

    Junkes, Monica C; Fraiz, Fabian C; Sardenberg, Fernanda; Lee, Jessica Y; Paiva, Saul M; Ferreira, Fernanda M

    2015-01-01

    The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. The BREALD-30 demonstrated good internal reliability. Cronbach's alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent's perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent's perception regarding his/her child's oral health remained significant in the multivariate analysis. The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil.

  9. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry – BREALD-30

    PubMed Central

    Junkes, Monica C.; Fraiz, Fabian C.; Sardenberg, Fernanda; Lee, Jessica Y.; Paiva, Saul M.; Ferreira, Fernanda M.

    2015-01-01

    Objective The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. Methods After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. Results The BREALD-30 demonstrated good internal reliability. Cronbach’s alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent’s perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent’s perception regarding his/her child's oral health remained significant in the multivariate analysis. Conclusion The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil. PMID:26158724

  10. Interrater and Test-Retest Reliability and Minimal Detectable Change of the Balance Evaluation Systems Test (BESTest) and Subsystems With Community-Dwelling Older Adults.

    PubMed

    Wang-Hsu, Elizabeth; Smith, Susan S

    2017-01-10

    Falls are a common cause of injuries and hospital admissions in older adults. Balance limitation is a potentially modifiable factor contributing to falls. The Balance Evaluation Systems Test (BESTest), a clinical balance measure, categorizes balance into 6 underlying subsystems. Each of the subsystems is scored individually and summed to obtain a total score. The reliability of the BESTest and its individual subsystems has been reported in patients with various neurological disorders and cancer survivors. However, the reliability and minimal detectable change (MDC) of the BESTest with community-dwelling older adults have not been reported. The purposes of our study were to (1) determine the interrater and test-retest reliability of the BESTest total and subsystem scores; and (2) estimate the MDC of the BESTest and its individual subsystem scores with community-dwelling older adults. We used a prospective cohort methodological design. Community-dwelling older adults (N = 70; aged 70-94 years; mean = 85.0 [5.5] years) were recruited from a senior independent living community. Trained testers (N = 3) administered the BESTest. All participants were tested with the BESTest by the same tester initially and then retested 7 to 14 days later. With 32 of the participants, a second tester concurrently scored the retest for interrater reliability. Testers were blinded to each other's scores. Intraclass correlation coefficients [ICC(2,1)] were used to determine the interrater and test-retest reliability. Test-retest reliability was also analyzed using method error and the associated coefficients of variation (CVME). MDC was calculated using standard error of measurement. Interrater reliability (N = 32) of the BESTest total score was ICC(2, 1) = 0.97 (95% confidence interval [CI], 0.94-0.99). The ICCs for the individual subsystem scores ranged from 0.85 to 0.94. Test-retest reliability (N = 70) of the BESTest total score was ICC(2,1) = 0.93 (95% CI, 0.89-0.96). ICCs for the individual subsystem scores ranged from 0.72 to 0.89. The CVME (N = 70) of the BESTest total score was 4.1%. The CVME for the subsystem scores ranged from 5.0% to 10.7%. MDC (N = 70) for the BESTest total score at the 95% CI was 7.6%, or 8.2 points. MDC at the 95% CI for subsystem scores ranged from 11.7% to 19.0% (2.1-3.4 points). Results demonstrated generally good to excellent interrater and test-retest reliability in both the BESTest total and subsystem scores with community-dwelling older adults. The BESTest total and individual subsystem scores demonstrate good to excellent interrater and test-retest reliability with community-dwelling older adults. A change of 7.6% (8.2 points) or more in the BESTest total and a percentage change ranged from 11.7% to 19.0% (2.1-3.4 points) in the subsystem scores are suggested for clinicians to be 95% confident of true change when evaluating change in this population.

  11. Economic Decision Making: Application of the Theory of Complex Systems

    NASA Astrophysics Data System (ADS)

    Kitt, Robert

    In this chapter the complex systems are discussed in the context of economic and business policy and decision making. It will be showed and motivated that social systems are typically chaotic, non-linear and/or non-equilibrium and therefore complex systems. It is discussed that the rapid change in global consumer behaviour is underway, that further increases the complexity in business and management. For policy making under complexity, following principles are offered: openness and international competition, tolerance and variety of ideas, self-reliability and low dependence on external help. The chapter contains four applications that build on the theoretical motivation of complexity in social systems. The first application demonstrates that small economies have good prospects to gain from the global processes underway, if they can demonstrate production flexibility, reliable business ethics and good risk management. The second application elaborates on and discusses the opportunities and challenges in decision making under complexity from macro and micro economic perspective. In this environment, the challenges for corporate management are being also permanently changed: the balance between short term noise and long term chaos whose attractor includes customers, shareholders and employees must be found. The emergence of chaos in economic relationships is demonstrated by a simple system of differential equations that relate the stakeholders described above. The chapter concludes with two financial applications: about debt and risk management. The non-equilibrium economic establishment leads to additional problems by using excessive borrowing; unexpected downturns in economy can more easily kill companies. Finally, the demand for quantitative improvements in risk management is postulated. Development of the financial markets has triggered non-linearity to spike in prices of various production articles such as agricultural and other commodities that has added market risk management to the business model of many companies.

  12. An analysis and demonstration of clock synchronization by VLBI

    NASA Technical Reports Server (NTRS)

    Hurd, W. J.

    1972-01-01

    A prototype of a semireal-time system for synchronizing the DSN station clocks by radio interferometry was successfully demonstrated. The system utilized an approximate maximum likelihood estimation procedure for processing the data, thereby achieving essentially optimum time synchronization estimates for a given amount of data, or equivalently, minimizing the amount of data required for reliable estimation. Synchronization accuracies as good as 100 nsec rms were achieved between DSS 11 and DSS 12, both at Goldstone, California. The accuracy can be improved by increasing the system bandwidth until the fundamental limitations due to position uncertainties of baseline and source and atmospheric effects are reached. These limitations are under ten nsec for transcontinental baselines.

  13. PedsQL™ Eosinophilic Esophagitis Module: Feasibility, Reliability and Validity

    PubMed Central

    Franciosi, James P.; Hommel, Kevin A.; Bendo, Cristiane B.; King, Eileen C.; Collins, Margaret H.; Eby, Michael D.; Marsolo, Keith; Abonia, J. Pablo; von Tiehl, Karl F.; Putnam, Philip E.; Greenler, Alexandria J.; Greenberg, Allison B.; Bryson, Ronald A.; Davis, Carla M.; Olive, Anthony P.; Gupta, Sandeep K.; Erwin, Elizabeth A.; Klinnert, Mary D.; Spergel, Jonathan M.; Denham, Jolanda M.; Furuta, Glenn T.; Rothenberg, Marc E.; Varni, James W.

    2014-01-01

    Objective Eosinophilic esophagitis (EoE) is a chronic esophageal inflammatory condition with a paucity of information on health-related quality of life (HRQOL). The objective of the study was to report on the measurement properties of the PedsQL™ EoE Module. Methods The PedsQL™ EoE Module was completed in a multisite study by 196 pediatric EoE patients and 262 EoE parents. Results The PedsQL™ EoE Module scales evidenced excellent feasibility (0.6%–3.1% missing), excellent group comparison reliability across total scale scores (patient α = 0.93; parent proxy α = 0.94), good reliability for the seven individual scales (patient α = 0.75–0.87; parent proxy α = 0.81–0.92), excellent test-retest reliability (patient ICC = 0.88; parent ICC= 0.82), demonstrated no floor effects and low ceiling effects, and demonstrated a high percentage of scaling success for most scales. Intercorrelations with the PedsQL™ Generic Core Scales were in the medium (0.30) to large (0.50) range. PedsQL™ EoE Module scores were worse among patients with active histologic disease (> 5 eos/hpf) compared to those in remission (patient self-report: 63.3 vs. 69.9 [p<0.05]; parent proxy-report: 65.1 vs. 72.3 [p<0.01]), and those treated with dietary restrictions compared to those with no restrictions (patient self-report: 61.6 vs. 74.3 [p< 0.01]; parent proxy-report: 65.5 vs. 74.7 [p<0.01]). Conclusions The results demonstrate excellent measurement properties of the PedsQL™ EoE Module. Patients with active histologic disease and those treated with dietary restrictions demonstrated worse PedsQL™ scores. The PedsQL™ EoE Module may be utilized in evaluation of pediatric EoE disease-specific HRQOL in clinical research and practice. PMID:23478422

  14. The career success scale in nursing: psychometric evidence to support the Chinese version.

    PubMed

    Li, Ze-kai; You, Li-ming; Lin, Han-sheng; Chan, Sally Wai-chi

    2014-05-01

    The purpose of this study was to examine the psychometric properties of the 11-item Chinese version of the Career Success Scale. Nurses play an important role in the healthcare system. Opportunities to achieve success and satisfaction from one's career affect the retention and stability of the nursing workforce. The Career Success Scale was originally developed in English and has been translated into Chinese. Psychometric testing of the Chinese Career Success Scale for measuring career success in nurses has not been performed. A cross-sectional survey was conducted. A convenience sample of 1148 clinical nurses were recruited from 10 level-3 hospitals in Guangdong Province, mainland China, from December 2010-December 2011. Results indicated that the Chinese Career Success Scale demonstrated good internal consistency and test-retest reliability. Principal component analysis supported the three-factor structure of the original instrument: Career Satisfaction, Perceived within Organization Competitiveness and Perceived External Organization Competitiveness. There were significant correlations among the three factors, which demonstrated the good construct validity of the Chinese version of this scale. The Chinese Career Success Scale appears to be a reliable and valid instrument. It has the potential to be used to measure nurses' career success in mainland China. The findings will be useful for nurse leaders and policymakers in the evaluation of nurses' self-perceived career success and to develop strategies to promote nurse retention and career development. © 2013 John Wiley & Sons Ltd.

  15. RhinAsthma patient perspective: A Rasch validation study.

    PubMed

    Molinengo, Giorgia; Baiardini, Ilaria; Braido, Fulvio; Loera, Barbara

    2018-02-01

    In daily practice, Health-Related Quality of Life (HRQoL) tools are useful for supplementing clinical data with the patient's perspective. To encourage their use by clinicians, the availability of tools that can quickly provide valid results is crucial. A new HRQoL tool has been proposed for patients with asthma and rhinitis: the RhinAsthma Patient Perspective-RAPP. The aim of this study was to evaluate the psychometric robustness of the RAPP using the Item Response Theory (IRT) approach, to evaluate the scalability of items and test whether or not patients use the items response scale correctly. 155 patients (53.5% women, mean age 39.1, range 16-76) were recruited during a multicenter study. RAPP metric properties were investigated using IRT models. Differential item functioning (DIF) was used for gender, age, and asthma control test (ACT). The RAPP adequately fitted the Rating Scale model, demonstrating the equality of the rating scale structure for all items. All statistics on items were satisfactory. The RAPP had adequate internal reliability and showed good ability to discriminate among different groups of participants. DIF analysis indicated that there were no differential item functioning issues for gender. One item showed a DIF by age and four items by ACT. The psychometric evaluation performed using IRT models demonstrated that the RAPP met all the criteria to be considered a reliable and valid method of measurement. From a clinical perspective, this will allow physicians to confidently interpret scores as good indicators of Quality of Life of patients with asthma.

  16. Development and Validation of the Food Liking Questionnaire in a French-Canadian Population

    PubMed Central

    Carbonneau, Elise; Bradette-Laplante, Maude; Lamarche, Benoît; Provencher, Véronique; Bégin, Catherine; Robitaille, Julie; Desroches, Sophie; Corneau, Louise; Lemieux, Simone

    2017-01-01

    The purpose of this study was to develop and validate a questionnaire assessing food liking in a French-Canadian population. A questionnaire was developed, in which participants were asked to rate their degree of liking of 50 food items. An expert panel evaluated the content validity. For the validation study, 150 men and women completed the questionnaire twice. An Exploratory Factor Analysis (EFA) was performed to assess the number of subscales of the questionnaire. Internal consistency and test-retest reliability of the subscales were evaluated. Concurrent validity was assessed through correlations between liking scores and self-reported frequencies of consumption. Comments from the experts led to changes in the list of foods included in the questionnaire. The EFA revealed a two-factor structure for the questionnaire (i.e., savory and sweet foods) and led to the removal of nine items, resulting in a 32-item questionnaire. The two subscales revealed good internal consistency (Cronbach alphas: 0.85 and 0.89) and test-retest reliability (p = 0.84 and 0.86). The questionnaire demonstrated adequate concurrent validity, with moderate correlations between food liking and self-reported frequency of consumption (r = 0.19–0.39, ps < 0.05). This new Food Liking Questionnaire assessing liking of a variety of savory and sweet foods demonstrated good psychometric properties in every validation step. This questionnaire will be useful to explore the role of food liking and its interactions with other factors in predicting eating behaviors and energy intake. PMID:29292754

  17. Development and Validation of the Food Liking Questionnaire in a French-Canadian Population.

    PubMed

    Carbonneau, Elise; Bradette-Laplante, Maude; Lamarche, Benoît; Provencher, Véronique; Bégin, Catherine; Robitaille, Julie; Desroches, Sophie; Vohl, Marie-Claude; Corneau, Louise; Lemieux, Simone

    2017-12-08

    The purpose of this study was to develop and validate a questionnaire assessing food liking in a French-Canadian population. A questionnaire was developed, in which participants were asked to rate their degree of liking of 50 food items. An expert panel evaluated the content validity. For the validation study, 150 men and women completed the questionnaire twice. An Exploratory Factor Analysis (EFA) was performed to assess the number of subscales of the questionnaire. Internal consistency and test-retest reliability of the subscales were evaluated. Concurrent validity was assessed through correlations between liking scores and self-reported frequencies of consumption. Comments from the experts led to changes in the list of foods included in the questionnaire. The EFA revealed a two-factor structure for the questionnaire (i.e., savory and sweet foods) and led to the removal of nine items, resulting in a 32-item questionnaire. The two subscales revealed good internal consistency (Cronbach alphas: 0.85 and 0.89) and test-retest reliability ( p = 0.84 and 0.86). The questionnaire demonstrated adequate concurrent validity, with moderate correlations between food liking and self-reported frequency of consumption ( r = 0.19-0.39, p s < 0.05). This new Food Liking Questionnaire assessing liking of a variety of savory and sweet foods demonstrated good psychometric properties in every validation step. This questionnaire will be useful to explore the role of food liking and its interactions with other factors in predicting eating behaviors and energy intake.

  18. Optimizing informed consent in living liver donors: Evaluation of a comprehension assessment tool.

    PubMed

    Gordon, Elisa J; Mullee, Jack; Butt, Zeeshan; Kang, Joseph; Baker, Talia

    2015-10-01

    Adult-to-adult living liver donation is associated with considerable risks with no direct medical benefit to liver donors (LDs). Ensuring that potential LDs comprehend the risks of donation is essential to medically and ethically justify the procedure. We developed and prospectively evaluated the initial psychometrics of an "Evaluation of Donor Informed Consent Tool" (EDICT) designed to assess LDs' comprehension about the living donation process. EDICT includes 49 true/false/unsure items related to LD informed consent. Consecutive LDs undergoing evaluation at 1 academic medical center from October 2012 to September 2014 were eligible for participation in pretest/posttest interviews. Medical records were reviewed for postdonation complications. Twenty-seven LDs participated (96% participation rate). EDICT demonstrated good internal consistency reliability at pretest, 2 days before donating (Cronbach's α = 0.78), and posttest, 1 week after donating (α = 0.70). EDICT scores significantly increased over time (P = 0.01) and demonstrated good test-retest reliability (r = 0.68; P < 0.001). EDICT was associated with race/ethnicity (P = 0.02) and relationship to the recipient (P = 0.01; pretest), and income (P = 0.01) and insurance (P = 0.01; posttest), but not with decisional conflict, preoperative preparedness, satisfaction, or decisional regret (pretest and posttest). Donor complications did not impact postdonation EDICT scores. In conclusion, EDICT has promising measurement properties and may be useful in the evaluation of informed consent for potential LDs. © 2015 American Association for the Study of Liver Diseases.

  19. Can we perceptually rate alaryngeal voice? Developing the Sunderland Tracheoesophageal Voice Perceptual Scale.

    PubMed

    Hurren, A; Hildreth, A J; Carding, P N

    2009-12-01

    To investigate the inter and intra reliability of raters (in relation to both profession and expertise) when judging two alaryngeal voice parameters: 'Overall Grade' and 'Neoglottal Tonicity'. Reliable perceptual assessment is essential for surgical and therapeutic outcome measurement but has been minimally researched to date. Test of inter and intra rater agreement from audio recordings of 55 tracheoesophageal speakers. Cancer Unit. Twelve speech and language therapists and ten Ear, Nose and Throat surgeons. Perceptual voice parameters of 'Overall Grade' rated with a 0-3 equally appearing interval scale and 'Neoglottal Tonicity' with an 11-point bipolar semantic scale. All raters achieved 'good' agreement for 'Overall Grade' with mean weighted kappa coefficients of 0.78 for intra and 0.70 for inter-rater agreement. All raters achieved 'good' intra-rater agreement for 'Neoglottal Tonicity' (0.64) but inter-rater agreement was only 'moderate' (0.40). However, the expert speech and language therapists sub-group attained 'good' inter-rater agreement with this parameter (0.63). The effect of 'Neoglottal Tonicity' on 'Overall Grade' was examined utilising only expert speech and language therapists data. Linear regression analysis resulted in an r-squared coefficient of 0.67. Analysis of the perceptual impression of hypotonicity and hypertonicity in relation to mean 'Overall Grade' score demonstrated neither tone was linked to a more favourable grade (P = 0.42). Expert speech and language therapist raters may be the optimal judges for tracheoesophageal voice assessment. Tonicity appears to be a good predictor of 'Overall Grade'. These scales have clinical applicability to investigate techniques that facilitate optotonic neoglottal voice quality.

  20. The Behavioural Assessment of Self-Structuring (BASS): psychometric properties in a post-acute brain injury rehabilitation programme.

    PubMed

    Jackson, Howard F; Tunstall, Victoria; Hague, Gemma; Daniels, Leanne; Crompton, Stacey; Taplin, Kimberly

    2014-01-01

    Jackson et al. (this edition) argue that structure is an important component in reducing the handicaps caused by cognitive impairments following acquired brain injury and that post-acute neuropsychological brain injury rehabilitation programmes should not only endeavour to provide structure but also aim to develop self-structuring. However, at present there is no standardized device for assessing self-structuring. To provide preliminary analysis of the psychometric properties of the Behavioural Assessment of Self-Structuring (BASS) staff rating scale (a 26 item informant five point rating scale based on the degree of support client requires to achieve self-structuring item). BASS data was utilised for clients attending residential rehabilitation. Reliability (inter-rarer and intra-rater), validity (construct, concurrent and discriminate) and sensitivity to change were investigated. Initial results indicate that the BASS has reasonably good reliability, good construct validity (via principal components analysis), good discriminant validity, and good concurrent validity correlating well with a number of other outcome measures (HoNOS; NPDS, Supervision Rating Scale, MPAI, FIM and FAM). The BASS did not correlate well with the NPCNA. Finally, the BASS was shown to demonstrate sensitivity to change. Although some caution is required in drawing firm conclusions at the present time and further exploration of the psychometric properties of the BASS is required, initial results are encouraging for the use of the BASS in assessing rehabilitation progress. These findings are discussed in terms of the value of the concept of self-structuring to the rehabilitation process for individuals with neuropsychological impairments consequent on acquired brain injury.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Hongying, E-mail: liuhongying@hdu.edu.cn; Gu, Chunchuan; Li, Dujuan

    Graphical abstract: A non-enzymatic H{sub 2}O{sub 2} sensor with high selectivity and sensitivity based on rose-shaped FeMoO{sub 4} synthesized by the convenient microwave-assisted hydrothermal method, was fabricated. - Highlights: • Rose-shaped FeMoO{sub 4} is synthesized within 10 min via microwave-assisted hydrothermal approach. • Non-enzymatic hydrogen peroxide biosensor based on FeMoO{sub 4} nanomaterials is fabricated. • The biosensor exhibits good performance. - Abstract: In this work, we demonstrated a simple, rapid and reliable microwave-assisted hydrothermal approach to synthesize the uniform rose-shaped FeMoO{sub 4} within 10 min. The morphologies of the synthesized materials were characterized by X-ray powder diffraction and scanning electronmore » microscopy. Moreover, a non-enzymatic amperometric sensor for the detection of hydrogen peroxide (H{sub 2}O{sub 2}) was fabricated on the basis of the FeMoO{sub 4} as electrocatalysis. The resulting FeMoO{sub 4} exhibited high sensitivity and good stability for the detection of H{sub 2}O{sub 2}, which may be attributed to the rose-shaped structure of the material and the catalytic property of FeMoO{sub 4}. Amperometric response showed that the modified electrode had a good response for H{sub 2}O{sub 2} with a linear range from 1 μM to 1.6 mM, a detection limit of 0.5 μM (S/N = 3), high selectivity and short response time. Additionally, good recoveries of analytes in real milk samples confirm the reliability of the prepared sensor in practical applications.« less

  2. Inter-rater reliability for movement pattern analysis (MPA): measuring patterning of behaviors versus discrete behavior counts as indicators of decision-making style

    PubMed Central

    Connors, Brenda L.; Rende, Richard; Colton, Timothy J.

    2014-01-01

    The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic – the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts – and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns. PMID:24999336

  3. Inter-rater reliability for movement pattern analysis (MPA): measuring patterning of behaviors versus discrete behavior counts as indicators of decision-making style.

    PubMed

    Connors, Brenda L; Rende, Richard; Colton, Timothy J

    2014-01-01

    The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic - the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts - and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from movement pattern analysis (MPA), an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective), inter-rater reliability for patterning (proportional indicators of each factor) was significantly higher and excellent (ICC = 0.89). Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring patterning versus discrete behavioral counts of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns.

  4. Development of a Comprehensive Assessment of Food Parenting Practices: The Home Self-Administered Tool for Environmental Assessment of Activity and Diet Family Food Practices Survey.

    PubMed

    Vaughn, Amber E; Dearth-Wesley, Tracy; Tabak, Rachel G; Bryant, Maria; Ward, Dianne S

    2017-02-01

    Parents' food parenting practices influence children's dietary intake and risk for obesity and chronic disease. Understanding the influence and interactions between parents' practices and children's behavior is limited by a lack of development and psychometric testing and/or limited scope of current measures. The Home Self-Administered Tool for Environmental Assessment of Activity and Diet (HomeSTEAD) was created to address this gap. This article describes development and psychometric testing of the HomeSTEAD family food practices survey. Between August 2010 and May 2011, a convenience sample of 129 parents of children aged 3 to 12 years were recruited from central North Carolina and completed the self-administered HomeSTEAD survey on three occasions during a 12- to 18-day window. Demographic characteristics and child diet were assessed at Time 1. Child height and weight were measured during the in-home observations (following Time 1 survey). Exploratory factor analysis with Time 1 data was used to identify potential scales. Scales with more than three items were examined for scale reduction. Following this, mean scores were calculated at each time point. Construct validity was assessed by examining Spearman rank correlations between mean scores (Time 1) and children's diet (fruits and vegetables, sugar-sweetened beverages, snacks, sweets) and body mass index (BMI) z scores. Repeated measures analysis of variance was used to examine differences in mean scores between time points, and single-measure intraclass correlations were calculated to examine test-retest reliability between time points. Exploratory factor analysis identified 24 factors and retained 124 items; however, scale reduction narrowed items to 86. The final instrument captures five coercive control practices (16 items), seven autonomy support practices (24 items), and 12 structure practices (46 items). All scales demonstrated good internal reliability (α>.62), 18 factors demonstrated construct validity (significant association with child diet, P<0.05), and 22 demonstrated good reliability (intraclass correlation coefficient>0.61). The HomeSTEAD family food practices survey provides a brief, yet comprehensive and psychometrically sound assessment of food parenting practices. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  5. Comparison between videofluoroscopy, fiberoptic endoscopy and scintigraphy for diagnosis of oro-pharyngeal dysphagia.

    PubMed

    Fattori, B; Giusti, P; Mancini, V; Grosso, M; Barillari, M R; Bastiani, L; Molinaro, S; Nacci, A

    2016-10-01

    The purpose of this study was to compare videofluoroscopy (VFS), fiberoptic endoscopic evaluation of swallowing (FEES) and oro-pharyngo- oesophageal scintigraphy (OPES) with regards to premature spillage, post-swallowing residue and aspiration to assess the reliability of these tests for detection of oro-pharyngeal dysphagia. Sixty patients affected with dysphagia of various origin were enrolled in the study and submitted to VFS, FEES and OPES using a liquid and semi-solid bolus. As a reference, we used VFS. Both the FEES and the OPES showed good sensitivity with high overall values (≥ 80% and ≥ 90% respectively). The comparison between FEES vs VFS concerning drop before swallowing showed good specificity (84.4% for semi-solids and 86.7% for liquids). In the case of post-swallowing residue, FEES vs VFS revealed good overall validity (75% for semi-solids) with specificity and sensitivity well balanced for the semi-solids. OPES vs. VFS demonstrated good sensitivity (88.6%) and overall validity (76.7%) for liquids. The analysis of FEES vs. VFS for aspiration showed that the overall validity was low (≤ 65%). On the other hand, OPES demonstrated appreciable overall validity (71.7%). VFS, FEES and OPES are capable of detecting oro-pharyngeal dysphagia. FEES gave significant results in the evaluation of post-swallowing residues. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  6. Multisite Reliability of Cognitive BOLD Data

    PubMed Central

    Brown, Gregory G.; Mathalon, Daniel H.; Stern, Hal; Ford, Judith; Mueller, Bryon; Greve, Douglas N.; McCarthy, Gregory; Voyvodic, Jim; Glover, Gary; Diaz, Michele; Yetter, Elizabeth; Burak Ozyurt, I.; Jorgensen, Kasper W.; Wible, Cynthia G.; Turner, Jessica A.; Thompson, Wesley K.; Potkin, Steven G.

    2010-01-01

    Investigators perform multi-site functional magnetic resonance imaging studies to increase statistical power, to enhance generalizability, and to improve the likelihood of sampling relevant subgroups. Yet undesired site variation in imaging methods could off-set these potential advantages. We used variance components analysis to investigate sources of variation in the blood oxygen level dependent (BOLD) signal across four 3T magnets in voxelwise and region of interest (ROI) analyses. Eighteen participants traveled to four magnet sites to complete eight runs of a working memory task involving emotional or neutral distraction. Person variance was more than 10 times larger than site variance for five of six ROIs studied. Person-by-site interactions, however, contributed sizable unwanted variance to the total. Averaging over runs increased between-site reliability, with many voxels showing good to excellent between-site reliability when eight runs were averaged and regions of interest showing fair to good reliability. Between-site reliability depended on the specific functional contrast analyzed in addition to the number of runs averaged. Although median effect size was correlated with between-site reliability, dissociations were observed for many voxels. Brain regions where the pooled effect size was large but between-site reliability was poor were associated with reduced individual differences. Brain regions where the pooled effect size was small but between-site reliability was excellent were associated with a balance of participants who displayed consistently positive or consistently negative BOLD responses. Although between-site reliability of BOLD data can be good to excellent, acquiring highly reliable data requires robust activation paradigms, ongoing quality assurance, and careful experimental control. PMID:20932915

  7. Development and Validation of the Pride in Eating Pathology Scale (PEP-S).

    PubMed

    Faija, Cintia L; Fox, John R E; Tierney, Stephanie; Peters, Sarah; Gooding, Patricia A

    2017-01-01

    There is a growing body of theoretical and clinical literature highlighting the role of pride in maintaining eating disordered behaviours. Despite its clinical importance, there are no measures to assess feelings of pride associated with eating psychopathology. This study describes the development and validation of the Pride in Eating Pathology Scale (PEP-S), a self-report questionnaire that examines feelings of pride towards eating disordered symptoms (e.g., pride in food restriction, thinness and weight loss). Participants were 390 females, recruited from university and community populations, whose mean age was 26.99 years. Respondents rated pride in eating pathology on a 7-point Likert-scale. Principal Component Analysis indicated that the 60-item scale comprised a four component structure: (1) pride in weight loss, food control and thinness, (2) pride in healthy weight and healthy eating, (3) pride in outperforming others and social recognition and (4) pride in capturing other people's attention due to extreme thinness. These four components explained a total of 65.31% of the variance. The PEP-S demonstrated very good internal reliability (α ranging from 0.88 to 0.98) and very good test-retest reliability over a 3-week time-span (r ranging from 0.81 to 0.93). The PEP-S also showed excellent convergent and discriminant validity. Furthermore, the scale discriminated between women with high and low levels of eating psychopathology. The PEP-S is a psychometrically robust measure of pride in eating pathology. It has the potential to advance theoretical understanding and may also be clinically useful. Copyright © 2015 John Wiley & Sons, Ltd. The PEP-S is a valid, reliable, quick and easy to administer self-report questionnaire that measures pride related to eating pathology. The PEP-S assesses four clinically relevant dimensions: (1) pride in weight loss, food control and thinness, (2) pride in healthy weight and healthy eating, (3) pride in outperforming others and social recognition and (4) pride in capturing other people's attention due to extreme thinness. The PEP-S has very good internal and test-retest reliability, and very good convergent and discriminant validity. The PEP-S distinguishes between women with higher and lower levels of eating psychopathology. The PEP-S makes an important contribution to understanding pride in eating psychopathology, which is essential from both clinical and theoretical perspectives. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Reliability and Validity of a New Method for Isometric Back Extensor Strength Evaluation Using A Hand-Held Dynamometer.

    PubMed

    Park, Hee-Won; Baek, Sora; Kim, Hong Young; Park, Jung-Gyoo; Kang, Eun Kyoung

    2017-10-01

    To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65-0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was -63.1 N and the upper 95% LoA was 61.1 N. This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity.

  9. The Trunk Impairment Scale - modified to ordinal scales in the Norwegian version.

    PubMed

    Gjelsvik, Bente; Breivik, Kyrre; Verheyden, Geert; Smedal, Tori; Hofstad, Håkon; Strand, Liv Inger

    2012-01-01

    To translate the Trunk Impairment Scale (TIS), a measure of trunk control in patients after stroke, into Norwegian (TIS-NV), and to explore its construct validity, internal consistency, intertester and test-retest reliability. TIS was translated according to international guidelines. The validity study was performed on data from 201 patients with acute stroke. Fifty patients with stroke and acquired brain injury were recruited to examine intertester and test-retest reliability. Construct validity was analyzed with exploratory and confirmatory factor analysis and item response theory, internal consistency with Cronbach's alpha test, and intertester and test-retest reliability with kappa and intraclass correlation coefficient tests. The back-translated version of TIS-NV was validated by the original developer. The subscale Static sitting balance was removed. By combining items from the subscales Dynamic sitting balance and Coordination, six ordinal superitems (testlets) were constructed. The TIS-NV was renamed the modified TIS-NV (TIS-modNV). After modifications the TIS-modNV fitted well to a locally dependent unidimensional item response theory model. It demonstrated good construct validity, excellent internal consistency, and high intertester and test-retest reliability for the total score. This study supports that the TIS-modNV is a valid and reliable scale for use in clinical practice and research.

  10. Reliability and Validity of the Work and Well-Being Inventory (WBI) for Employees.

    PubMed

    Vendrig, A A; Schaafsma, F G

    2018-06-01

    Purpose The purpose of this study is to measure the psychometric properties of the Work and Wellbeing Inventory (WBI) (in Dutch: VAR-2), a screening tool that is used within occupational health care and rehabilitation. Our research question focused on the reliability and validity of this inventory. Methods Over the years seven different samples of workers, patients and sick listed workers varying in size between 89 and 912 participants (total: 2514), were used to measure the test-retest reliability, the internal consistency, the construct and concurrent validity, and the criterion and predictive validity. Results The 13 scales displayed good internal consistency and test-retest reliability. The constructive validity of the WBI could clearly be demonstrated in both patients and healthy workers. Confirmative factor analyses revealed a CFI >.90 for all scales. The depression scale predicted future work absenteeism (>6 weeks) because of a common mental disorder in healthy workers. The job strain scale and the illness behavior scale predicted long term absenteeism (>3 months) in workers with short-term absenteeism. The illness behavior scale moderately predicted return to work in rehab patients attending an intensive multidisciplinary program. Conclusions The WBI is a valid and reliable tool for occupational health practitioners to screen for risk factors for prolonged or future sickness absence. With this tool they will have reliable indications for further advice and interventions to restore the work ability.

  11. Investigations of FAK inhibitors: a combination of 3D-QSAR, docking, and molecular dynamics simulations studies.

    PubMed

    Cheng, Peng; Li, Jiaojiao; Wang, Juan; Zhang, Xiaoyun; Zhai, Honglin

    2018-05-01

    Focal adhesion kinase (FAK) is one kind of tyrosine kinases that modulates integrin and growth factor signaling pathways, which is a promising therapeutic target because of involving in cancer cell migration, proliferation, and survival. To investigate the mechanism between FAK and triazinic inhibitors and design high activity inhibitors, a molecular modeling integrated with 3D-QSAR, molecular docking, molecular dynamics simulations, and binding free energy calculations was performed. The optimum CoMFA and CoMSIA models showed good reliability and satisfactory predictability (with Q 2  = 0.663, R 2  = 0.987, [Formula: see text] = 0.921 and Q 2  = 0.670, R 2  = 0.981, [Formula: see text] = 0.953). Its contour maps could provide structural features to improve inhibitory activity. Furthermore, a good consistency between contour maps, docking, and molecular dynamics simulations strongly demonstrates that the molecular modeling is reliable. Based on it, we designed several new compounds and their inhibitory activities were validated by the molecular models. We expect our studies could bring new ideas to promote the development of novel inhibitors with higher inhibitory activity for FAK.

  12. Cross-cultural adaptation and validation of the Italian version of the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow score.

    PubMed

    Merolla, Giovanni; Corona, Katia; Zanoli, Gustavo; Cerciello, Simone; Giannotti, Stefano; Porcellini, Giuseppe

    2017-12-01

    The Kerlan-Jobe Orthopaedic Clinic (KJOC) Shoulder and Elbow score is a reliable and sensitive tool to measure the performance of overhead athletes. The purpose of this study was to carry out a cross-cultural adaptation and validation of the KJOC questionnaire in Italian and to assess its reliability, validity, and responsiveness. Ninety professional athletes with a painful shoulder were included in this study and were assigned to the "injury group" (n = 32) or the "overuse group" (n = 58); 65 were managed conservatively and 25 were treated by arthroscopic surgery. To assess the reliability of the KJOC score, patients were asked to fill in the questionnaire at baseline and after 2 weeks. To test the construct validity, KJOC scores were compared to those obtained with the Italian version of the Disabilities of the Arm, Shoulder, and Hand (DASH) scale, and with the DASH sports/performing arts module. To test KJOC score responsiveness, the follow-up KJOC scores of the participants treated conservatively were compared to those of the patients treated by arthroscopic surgery. Statistical analysis demonstrated that the KJOC questionnaire is reliable in terms of the single items and the overall score (ICC 0.95-0.99); that it has high construct validity (r s  = -0.697; p < 0.01); and that it is responsive to clinical differences in shoulder function (p < 0.0001). The Italian version of the KJOC Shoulder and Elbow score performed in a similar way to the English version and demonstrated good validity, reliability, and responsiveness after conservative and surgical treatment. II.

  13. Demonstrating Test-Retest Reliability of Electrophysiological Measures for Healthy Adults in a Multisite Study of Biomarkers of Antidepressant Treatment Response

    PubMed Central

    Tenke, Craig E.; Kayser, Jürgen; Pechtel, Pia; Webb, Christian A.; Dillon, Daniel G.; Goer, Franziska; Murray, Laura; Deldin, Patricia; Kurian, Benji T.; McGrath, Patrick J.; Parsey, Ramin; Trivedi, Madhukar; Fava, Maurizio; Weissman, Myrna M.; McInnis, Melvin; Abraham, Karen; Alvarenga, Jorge; Alschuler, Daniel M.; Cooper, Crystal; Pizzagalli, Diego A.; Bruder, Gerard E.

    2016-01-01

    Growing evidence suggests that loudness dependency of auditory evoked potentials (LDAEP) and resting EEG alpha and theta may be biological markers for predicting response to antidepressants. In spite of this promise, little is known about the joint reliability of these markers, and thus their clinical applicability. New, standardized procedures were developed to improve the compatibility of data acquired with different EEG platforms, and used to examine test-retest reliability for the three electrophysiological measures selected for a multisite project—Establishing Moderators and Biosignatures of Antidepressant Response for Clinical Care (EMBARC). Thirty nine healthy controls across four clinical research sites were tested in two sessions separated by about one week. Resting EEG (eyes-open and eyes-closed conditions) was recorded and LDAEP measured using binaural tones (1000 Hz, 40 ms) at five intensities (60–100 dB SPL). Principal components analysis (PCA) of current source density (CSD) waveforms reduced volume conduction and provided reference-free measures of resting EEG alpha and N1 dipole activity to tones from auditory cortex. Low Resolution Electromagnetic Tomography (LORETA) extracted resting theta current density measures corresponding to rostral anterior cingulate (rACC), which has been implicated in treatment response. There were no significant differences in posterior alpha, N1 dipole or rACC theta across sessions. Test-retest reliability was .84 for alpha, .87 for N1 dipole, and .70 for theta rACC current density. The demonstration of good-to-excellent reliability for these measures provides a template for future EEG/ERP studies from multiple testing sites, and an important step for evaluating them as biomarkers for predicting treatment response. PMID:28000259

  14. Reliability and validity of an arabic version of the dyspnea-12 questionnaire for Saudi nationals with chronic obstructive pulmonary disease.

    PubMed

    Alyami, Mohammed M; Jenkins, Sue C; Lababidi, Hani; Hill, Kylie

    2015-01-01

    Dyspnea is a distressing symptom experienced by people with chronic obstructive pulmonary disease (COPD). The dyspnea-12 (D-12) questionnaire comprises of 12 items and assesses the quality of this symptom, its severity and the emotional response. The original (English) version of the D-12 is reliable and valid for the measurement of dyspnea in pulmonary diseases. To translate the D-12 into Arabic and determine whether this version is reliable and valid in Saudi nationals with COPD. The D-12 was translated into Arabic version and reviewed by an expert panel before being back-translated into English. The Arabic version was administered to five patients with COPD to test whether it was easily understood after which a final Arabic version was produced. Thereafter, 40 patients with COPD (aged 63 ΁ 9 years; 33 [82.5%] males; forced expiratory volume in one second (FEV 1) 47 ΁ 16% predicted) completed the D-12, the COPD Assessment Test (CAT) and the Chronic Respiratory Disease Questionnaire (CRDQ). Lung function and 6-minute walk distance were also measured. The D-12 was re-administered two weeks later. The Arabic version of the D-12 demonstrated good reliability over the two administration (intraclass correlation coefficient = 0.94, P = 0.01). Strong associations were demonstrated between the (1) total score for the D-12 and the CAT, (2) quality sub-score of the D-12 and the CAT and (3) emotional response sub-score of the D-12 and emotional function domain of the CRDQ (r ≥ 0.6, all P < 0.01). The Arabic version of the D-12 is a reliable and valid instrument in Saudi nationals with COPD.

  15. Demonstrating test-retest reliability of electrophysiological measures for healthy adults in a multisite study of biomarkers of antidepressant treatment response.

    PubMed

    Tenke, Craig E; Kayser, Jürgen; Pechtel, Pia; Webb, Christian A; Dillon, Daniel G; Goer, Franziska; Murray, Laura; Deldin, Patricia; Kurian, Benji T; McGrath, Patrick J; Parsey, Ramin; Trivedi, Madhukar; Fava, Maurizio; Weissman, Myrna M; McInnis, Melvin; Abraham, Karen; E Alvarenga, Jorge; Alschuler, Daniel M; Cooper, Crystal; Pizzagalli, Diego A; Bruder, Gerard E

    2017-01-01

    Growing evidence suggests that loudness dependency of auditory evoked potentials (LDAEP) and resting EEG alpha and theta may be biological markers for predicting response to antidepressants. In spite of this promise, little is known about the joint reliability of these markers, and thus their clinical applicability. New standardized procedures were developed to improve the compatibility of data acquired with different EEG platforms, and used to examine test-retest reliability for the three electrophysiological measures selected for a multisite project-Establishing Moderators and Biosignatures of Antidepressant Response for Clinical Care (EMBARC). Thirty-nine healthy controls across four clinical research sites were tested in two sessions separated by about 1 week. Resting EEG (eyes-open and eyes-closed conditions) was recorded and LDAEP measured using binaural tones (1000 Hz, 40 ms) at five intensities (60-100 dB SPL). Principal components analysis of current source density waveforms reduced volume conduction and provided reference-free measures of resting EEG alpha and N1 dipole activity to tones from auditory cortex. Low-resolution electromagnetic tomography (LORETA) extracted resting theta current density measures corresponding to rostral anterior cingulate (rACC), which has been implicated in treatment response. There were no significant differences in posterior alpha, N1 dipole, or rACC theta across sessions. Test-retest reliability was .84 for alpha, .87 for N1 dipole, and .70 for theta rACC current density. The demonstration of good-to-excellent reliability for these measures provides a template for future EEG/ERP studies from multiple testing sites, and an important step for evaluating them as biomarkers for predicting treatment response. © 2016 Society for Psychophysiological Research.

  16. Development and testing of the cancer multidisciplinary team meeting observational tool (MDT-MOT)

    PubMed Central

    Harris, Jenny; Taylor, Cath; Sevdalis, Nick; Jalil, Rozh; Green, James S.A.

    2016-01-01

    Abstract Objective To develop a tool for independent observational assessment of cancer multidisciplinary team meetings (MDMs), and test criterion validity, inter-rater reliability/agreement and describe performance. Design Clinicians and experts in teamwork used a mixed-methods approach to develop and refine the tool. Study 1 observers rated pre-determined optimal/sub-optimal MDM film excerpts and Study 2 observers independently rated video-recordings of 10 MDMs. Setting Study 2 included 10 cancer MDMs in England. Participants Testing was undertaken by 13 health service staff and a clinical and non-clinical observer. Intervention None. Main Outcome Measures Tool development, validity, reliability/agreement and variability in MDT performance. Results Study 1: Observers were able to discriminate between optimal and sub-optimal MDM performance (P ≤ 0.05). Study 2: Inter-rater reliability was good for 3/10 domains. Percentage of absolute agreement was high (≥80%) for 4/10 domains and percentage agreement within 1 point was high for 9/10 domains. Four MDTs performed well (scored 3+ in at least 8/10 domains), 5 MDTs performed well in 6–7 domains and 1 MDT performed well in only 4 domains. Leadership and chairing of the meeting, the organization and administration of the meeting, and clinical decision-making processes all varied significantly between MDMs (P ≤ 0.01). Conclusions MDT-MOT demonstrated good criterion validity. Agreement between clinical and non-clinical observers (within one point on the scale) was high but this was inconsistent with reliability coefficients and warrants further investigation. If further validated MDT-MOT might provide a useful mechanism for the routine assessment of MDMs by the local workforce to drive improvements in MDT performance. PMID:27084499

  17. Development and testing of the cancer multidisciplinary team meeting observational tool (MDT-MOT).

    PubMed

    Harris, Jenny; Taylor, Cath; Sevdalis, Nick; Jalil, Rozh; Green, James S A

    2016-06-01

    To develop a tool for independent observational assessment of cancer multidisciplinary team meetings (MDMs), and test criterion validity, inter-rater reliability/agreement and describe performance. Clinicians and experts in teamwork used a mixed-methods approach to develop and refine the tool. Study 1 observers rated pre-determined optimal/sub-optimal MDM film excerpts and Study 2 observers independently rated video-recordings of 10 MDMs. Study 2 included 10 cancer MDMs in England. Testing was undertaken by 13 health service staff and a clinical and non-clinical observer. None. Tool development, validity, reliability/agreement and variability in MDT performance. Study 1: Observers were able to discriminate between optimal and sub-optimal MDM performance (P ≤ 0.05). Study 2: Inter-rater reliability was good for 3/10 domains. Percentage of absolute agreement was high (≥80%) for 4/10 domains and percentage agreement within 1 point was high for 9/10 domains. Four MDTs performed well (scored 3+ in at least 8/10 domains), 5 MDTs performed well in 6-7 domains and 1 MDT performed well in only 4 domains. Leadership and chairing of the meeting, the organization and administration of the meeting, and clinical decision-making processes all varied significantly between MDMs (P ≤ 0.01). MDT-MOT demonstrated good criterion validity. Agreement between clinical and non-clinical observers (within one point on the scale) was high but this was inconsistent with reliability coefficients and warrants further investigation. If further validated MDT-MOT might provide a useful mechanism for the routine assessment of MDMs by the local workforce to drive improvements in MDT performance. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  18. The interplay between academic performance and quality of life among preclinical students.

    PubMed

    Shareef, Mohammad Abrar; AlAmodi, Abdulhadi A; Al-Khateeb, Abdulrahman A; Abudan, Zainab; Alkhani, Mohammed A; Zebian, Sanderlla I; Qannita, Ahmed S; Tabrizi, Mariam J

    2015-10-31

    The high academic performance of medical students greatly influences their professional competence in long term career. Meanwhile, medical students greatly demand procuring a good quality of life that can help them sustain their medical career. This study examines validity and reliability of the tool among preclinical students and testifies the influence of their scholastic performance along with gender and academic year on their quality of life. A cross sectional study was conducted by distributing World Health Organization Quality of Life, WHOQOL-BREF, survey among medical students of year one to three at Alfaisal University. For validity, item discriminate validity(IDV) and confirmatory factor analysis were measured and for reliability, Cronbach's α test and internal item consistency(IIC) were examined. The association of GPA, gender and academic year with all major domains was drawn using Pearson's correlation, independent samples t-test and one-way ANOVA, respectively. A total of 335 preclinical students have responded to this questionnaire. The construct has demonstrated an adequate validity and good reliability. The high academic performance of students positively correlated with physical (r = 0.23, p < 0.001), psychological health (r = 0.29, p < 0.001), social relations (r = 0.11, p = 0.03) and environment (r = 0.23, p < 0.001). Male student scored higher than female peers in physical and psychological health. This study has identified a direct relationship between the academic performance of preclinical students and their quality of life. The WHOQOL-BREF is a valid and reliable tool among preclinical students and the positive direction of high academic performance with greater QOL suggests that academic achievers procure higher satisfaction and poor achievers need a special attention for the improvement of their quality of life.

  19. Psychometric validation of the functional assessment of cancer therapy--brain (FACT-Br) for assessing quality of life in patients with brain metastases.

    PubMed

    Thavarajah, Nemica; Bedard, Gillian; Zhang, Liying; Cella, David; Beaumont, Jennifer L; Tsao, May; Barnes, Elizabeth; Danjoux, Cyril; Sahgal, Arjun; Soliman, Hany; Chow, Edward

    2014-04-01

    This study aimed to test the reliability, psychometric, and clinical validity of the use of the Functional Assessment of Cancer Therapy--Brain (FACT-Br) in patients with brain metastases. Patients with brain metastases were interviewed using the FACT-Br (including the FACT-general) 1 week prior to treatment. All patients completed a follow-up assessment 1 month post-treatment. Patients with a good performance status and receiving stereotactic radiosurgery completed an additional 1 week follow-up assessment after the initial baseline interview to assess test-retest reliability. Forty patients had complete 1 month follow-up data. Ten of these patients also completed the 1 week follow-up assessment from baseline. The median Karnofsky performance status of patients was 80 and the median age was 64 years. All subscales of the FACT-Br were found to be conceptually related (except for two correlations) using the following subscales: physical well-being (PWB), social/family well-being (SWB), emotional well-being (EWB), functional well-being (FWB), FACT-G total score, brain cancer subscale (BrC), and the FACT-Br total score. All FACT-Br scores demonstrated excellent reliability, except for the SWB scale which revealed good reliability. The FACT-Br scores showed no significant change in the quality of life (QoL) of patients from baseline to 1 month follow-up. The use of the combined FACT-G and FACT-Br Subscale to assess QoL specifically in patients with brain metastases has successfully undergone psychometric validation. Future clinical trials should use the FACT-G and FACT-Br Subscale to assess QoL in this patient population.

  20. Interrater reliability among epilepsy centers: multicenter study of epilepsy surgery.

    PubMed

    Haut, Sheryl R; Berg, Anne T; Shinnar, Shlomo; Cohen, Hillel W; Bazil, Carl W; Sperling, Michael R; Langfitt, John T; Pacia, Steven V; Walczak, Thaddeus S; Spencer, Susan S

    2002-11-01

    To measure the interrater reliability of presurgical testing and surgical decisions among epilepsy centers. Seven centers participating in an ongoing, prospective multicenter study of resective epilepsy surgery agreed to conform to a detailed protocol regarding presurgical evaluation and surgery. To assess quality assurance, each center independently reviewed 21 randomly selected surgical cases for preoperative study lateralization and localization, and surgical decisions. Interrater reliability was assessed by using intraclass correlation coefficients (ICCs), validated for use with multiple raters, and calculated in a two-way random model based on absolute agreement. Agreement for ICC values: > or = 0.75, excellent; 0.60-0.74, good; 0.40-0.59, fair; < or = 0.39, poor. One center was excluded for missing data. Agreement was excellent for extracranial EEG lateralization (0.8039), magnetic resonance imaging (MRI) lateralization (0.9521) and localization (0.9130), Wada lateralization (0.9453), and intracranial EEG localization (0.7905). Agreement was good for extracranial EEG localization (0.7384) and neuropsychological testing lateralization (0.7178) and localization (0.6891). Consensus about the decision to perform intracranial monitoring was fair (0.5397), in part reflecting one center's tendency toward intracranial monitoring. Overall agreements on whether to perform surgery (0.8311) and specific surgery recommended (0.8164) were excellent. High interrater reliability among six epilepsy centers was present for interpretation of most components of presurgical testing. Although consensus for the decision to perform intracranial monitoring was only fair, agreements for the ultimate decision about resective surgery and specific choice of resection were excellent. We believe that this study demonstrates the feasibility of implementing multicenter protocols for neurologic management, especially those involving localization, as well as protocols combining study results with clinical decision making.

  1. Developing the Person-Environment Apathy Rating for persons with dementia.

    PubMed

    Jao, Ying-Ling; Algase, Donna L; Specht, Janet K; Williams, Kristine

    2016-08-01

    To develop the Person-Environment Apathy Rating (PEAR) scale that measures environmental stimulation and apathy in persons with dementia and to evaluate its psychometrics. The PEAR scale consists of the PEAR-Environment subscale and PEAR-Apathy subscales. The items were developed via literature review, field testing, expert review, and pilot testing. The construct validity and reliability were examined through video observation. The parent study enrolled 185 institutionalized residents with dementia. For this study, 96 videos were selected from 24 participants. The PEAR-Environment subscale was validated using the Ambiance Scale and the Crowding Index. The PEAR-Apathy subscale was validated using the Neuropsychiatric Inventory (NPI)-Apathy, Passivity in Dementia Scale (PDS), and NPI-Depression. The PEAR-Environment subscale and PEAR-Apathy subscales each consists of six items rated on a 1-4 scale. For validity, the Crowding Index slightly, yet significantly, correlated with the PEAR-Environment subscale total score and three of the individual scores. Ambiance Scale scores, both engaging and soothing, did not correlate with the PEAR-Environment subscale. The PEAR-Apathy highly correlated with the PDS and NPI-Apathy and moderately correlated with the NPI-Depression, suggesting good convergent validity and moderate discriminant validity. For reliability, both environment and apathy subscales demonstrated excellent internal consistency. Although facial expression and eye contact showed moderate inter-rater reliability, all other items showed good to excellent inter-rater and intra-rater reliability. This study has successfully developed the PEAR scale and established its psychometrics based on the compatible scales available. The PEAR scale is the first scale that concurrently assesses apathy and environmental stimulation, and is recommended for use in persons with dementia.

  2. Development and Validation of a Practical Instrument for Injury Prevention: The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT).

    PubMed

    Sun, Yi; Arning, Martin; Bochmann, Frank; Börger, Jutta; Heitmann, Thomas

    2018-06-01

    The Occupational Safety and Health Monitoring and Assessment Tool (OSH-MAT) is a practical instrument that is currently used in the German woodworking and metalworking industries to monitor safety conditions at workplaces. The 12-item scoring system has three subscales rating technical, organizational, and personnel-related conditions in a company. Each item has a rating value ranging from 1 to 9, with higher values indicating higher standard of safety conditions. The reliability of this instrument was evaluated in a cross-sectional survey among 128 companies and its validity among 30,514 companies. The inter-rater reliability of the instrument was examined independently and simultaneously by two well-trained safety engineers. Agreement between the double ratings was quantified by the intraclass correlation coefficient and absolute agreement of the rating values. The content validity of the OSH-MAT was evaluated by quantifying the association between OSH-MAT values and 5-year average injury rates by Poisson regression analysis adjusted for the size of the companies and industrial sectors. The construct validity of OSH-MAT was examined by principle component factor analysis. Our analysis indicated good to very good inter-rater reliability (intraclass correlation coefficient = 0.64-0.74) of OSH-MAT values with an absolute agreement of between 72% and 81%. Factor analysis identified three component subscales that met exactly the structure theory of this instrument. The Poisson regression analysis demonstrated a statistically significant exposure-response relationship between OSH-MAT values and the 5-year average injury rates. These analyses indicate that OSH-MAT is a valid and reliable instrument that can be used effectively to monitor safety conditions at workplaces.

  3. Translation, adaptation and validation of a Portuguese version of the Moorehead-Ardelt Quality of Life Questionnaire II.

    PubMed

    Maciel, João; Infante, Paulo; Ribeiro, Susana; Ferreira, André; Silva, Artur C; Caravana, Jorge; Carvalho, Manuel G

    2014-11-01

    The prevalence of obesity has increased worldwide. An assessment of the impact of obesity on health-related quality of life (HRQoL) requires specific instruments. The Moorehead-Ardelt Quality of Life Questionnaire II (MA-II) is a widely used instrument to assess HRQoL in morbidly obese patients. The objective of this study was to translate and validate a Portuguese version of the MA-II.The study included forward and backward translations of the original MA-II. The reliability of the Portuguese MA-II was estimated using the internal consistency and test-retest methods. For validation purposes, the Spearman's rank correlation coefficient was used to evaluate the correlation between the Portuguese MA-II and the Portuguese versions of two other questionnaires, the 36-item Short Form Health Survey (SF-36) and the Impact of Weight on Quality of Life-Lite (IWQOL-Lite).One hundred and fifty morbidly obese patients were randomly assigned to test the reliability and validity of the Portuguese MA-II. Good internal consistency was demonstrated by a Cronbach's alpha coefficient of 0.80, and a very good agreement in terms of test-retest reliability was recorded, with an overall intraclass correlation coefficient (ICC) of 0.88. The total sums of MA-II scores and each item of MA-II were significantly correlated with all domains of SF-36 and IWQOL-Lite. A statistically significant negative correlation was found between the MA-II total score and BMI. Moreover, age, gender and surgical status were independent predictors of MA-II total score.A reliable and valid Portuguese version of the MA-II was produced, thus enabling the routine use of MA-II in the morbidly obese Portuguese population.

  4. Validity and reliability of Nike + Fuelband for estimating physical activity energy expenditure.

    PubMed

    Tucker, Wesley J; Bhammar, Dharini M; Sawyer, Brandon J; Buman, Matthew P; Gaesser, Glenn A

    2015-01-01

    The Nike + Fuelband is a commercially available, wrist-worn accelerometer used to track physical activity energy expenditure (PAEE) during exercise. However, validation studies assessing the accuracy of this device for estimating PAEE are lacking. Therefore, this study examined the validity and reliability of the Nike + Fuelband for estimating PAEE during physical activity in young adults. Secondarily, we compared PAEE estimation of the Nike + Fuelband with the previously validated SenseWear Armband (SWA). Twenty-four participants (n = 24) completed two, 60-min semi-structured routines consisting of sedentary/light-intensity, moderate-intensity, and vigorous-intensity physical activity. Participants wore a Nike + Fuelband and SWA, while oxygen uptake was measured continuously with an Oxycon Mobile (OM) metabolic measurement system (criterion). The Nike + Fuelband (ICC = 0.77) and SWA (ICC = 0.61) both demonstrated moderate to good validity. PAEE estimates provided by the Nike + Fuelband (246 ± 67 kcal) and SWA (238 ± 57 kcal) were not statistically different than OM (243 ± 67 kcal). Both devices also displayed similar mean absolute percent errors for PAEE estimates (Nike + Fuelband = 16 ± 13 %; SWA = 18 ± 18 %). Test-retest reliability for PAEE indicated good stability for Nike + Fuelband (ICC = 0.96) and SWA (ICC = 0.90). The Nike + Fuelband provided valid and reliable estimates of PAEE, that are similar to the previously validated SWA, during a routine that included approximately equal amounts of sedentary/light-, moderate- and vigorous-intensity physical activity.

  5. A Method to Prevent Protein Delocalization in Imaging Mass Spectrometry of Non-Adherent Tissues: Application to Small Vertebrate Lens Imaging

    PubMed Central

    Anderson, David M. G.; Floyd, Kyle A.; Barnes, Stephen; Clark, Judy M.; Clark, John I.; Mchaourab, Hassane; Schey, Kevin L.

    2015-01-01

    MALDI imaging requires careful sample preparation to obtain reliable, high quality images of small molecules, peptides, lipids, and proteins across tissue sections. Poor crystal formation, delocalization of analytes, and inadequate tissue adherence can affect the quality, reliability, and spatial resolution of MALDI images. We report a comparison of tissue mounting and washing methods that resulted in an optimized method using conductive carbon substrates that avoids thaw mounting or washing steps, minimizes protein delocalization, and prevents tissue detachment from the target surface. Application of this method to image ocular lens proteins of small vertebrate eyes demonstrates the improved methodology for imaging abundant crystallin protein products. This method was demonstrated for tissue sections from rat, mouse, and zebrafish lenses resulting in good quality MALDI images with little to no delocalization. The images indicate, for the first time in mouse and zebrafish, discrete localization of crystallin protein degradation products resulting in concentric rings of distinct protein contents that may be responsible for the refractive index gradient of vertebrate lenses. PMID:25665708

  6. Very Large Scale Optimization

    NASA Technical Reports Server (NTRS)

    Vanderplaats, Garrett; Townsend, James C. (Technical Monitor)

    2002-01-01

    The purpose of this research under the NASA Small Business Innovative Research program was to develop algorithms and associated software to solve very large nonlinear, constrained optimization tasks. Key issues included efficiency, reliability, memory, and gradient calculation requirements. This report describes the general optimization problem, ten candidate methods, and detailed evaluations of four candidates. The algorithm chosen for final development is a modern recreation of a 1960s external penalty function method that uses very limited computer memory and computational time. Although of lower efficiency, the new method can solve problems orders of magnitude larger than current methods. The resulting BIGDOT software has been demonstrated on problems with 50,000 variables and about 50,000 active constraints. For unconstrained optimization, it has solved a problem in excess of 135,000 variables. The method includes a technique for solving discrete variable problems that finds a "good" design, although a theoretical optimum cannot be guaranteed. It is very scalable in that the number of function and gradient evaluations does not change significantly with increased problem size. Test cases are provided to demonstrate the efficiency and reliability of the methods and software.

  7. Reliability and Validity of the Multidimensional Scale of Perceived Social Support (MSPSS): Thai Version.

    PubMed

    Wongpakaran, Tinakon; Wongpakaran, Nahathai; Ruktrakul, Ruk

    2011-01-01

    This study examines the Thai version of the Multidimensional Scale of Perceived Social Support (MSPSS) for its psychometric properties. In total 462 participants were recruited - 310 medical students from Chiang Mai University and 152 psychiatric patients, and they completed the Thai version of the MSPSS, the State Trait Anxiety Inventory (STAI), the Rosenberg Self-Esteem Scale (RSES) and the Thai Depression Inventory (TDI). Test-retest reliability was conducted over a four week period. Factor analysis produced three-factor solutions for both patient (PG) and student groups (SG), and overall the model demonstrated adequate fit indices. The mean total score and the sub-scale score for the SG were statistically higher than those in the PG, except for 'Significant Others'. The internal consistency of the scale was good, with a Cronbach's alpha of 0.91 for the SG and 0.87 for the PG. After a four week retest for reliability exercise, the intra-class correlation coefficient (ICC) was found to be 0.84. The Thai-MSPSS was found to have a negative correlation with the STAI and the TDI, but was positively correlated with the RSES. The Thai MSPSS is a reliable and valid instrument to use.

  8. Construct validity, test-retest reliability and internal consistency of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) in patients with carpal tunnel syndrome.

    PubMed

    Buntragulpoontawee, Montana; Phutrit, Suphatha; Tongprasert, Siam; Wongpakaran, Tinakon; Khunachiva, Jeeranan

    2018-03-27

    This study evaluated additional psychometric properties of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) which included, test-retest reliability, construct validity, internal consistency of in patients with carpal tunnel syndrome. As for determining construct validity, the Thai EuroQOL questionnaire (EQ-5D-5L) was also administered in order to examine convergent and divergent validity. Fifty patients completed both questionnaires. The DASH-TH showed excellent test-retest reliability (intraclass correlation coefficient = 0.811) and internal consistency (Cronbach's alpha = 0.911). The exploratory factor analysis yielded a six-factor solution while the confirmatory factor analysis denoted that the hypothesized model adequately fit the data with a comparative fit index of 0.967 and a Tucker-Lewis index of 0.964. The related subscales between the DASH-TH and the Thai EQ-5D-5L were significantly correlated, indicating the DASH-TH's convergent and discriminant validity. The DASH-TH demonstrated good reliability, internal consistency construct validity, and multidimensionality, in assessing the upper extremity function in carpal tunnel syndrome patients.

  9. Psychometric Evaluation of the Patient Health Questionnaire-4 in Hispanic Americans.

    PubMed

    Mills, Sarah D; Fox, Rina S; Pan, Tonya M; Malcarne, Vanessa L; Roesch, Scott C; Sadler, Georgia Robins

    2015-11-01

    The present study evaluated the psychometric properties of the Patient Health Questionnaire-4 (PHQ-4), a screener of psychological distress, in English- and Spanish-speaking Hispanic Americans. Hispanic American adults ( N = 436) completed the PHQ-4, which yields two subscales (anxiety and depression) that can be summed to create a total score. Multiple-group confirmatory factor analysis was used to evaluate structural validity. The two-factor structure was the best fit to the data for both English- and Spanish-speaking Hispanic Americans and items loaded equivalently across groups, demonstrating measurement invariance. Internal consistency reliability was good as measured by coefficient alpha. Construct validity was evidenced by significant expected relationships with perceived stress. These findings provide support for the reliability and validity of the PHQ-4 as a brief measure of psychological distress for English- or Spanish-speaking Hispanic Americans.

  10. Evaluation of the Williams-type model for barley yields in North Dakota and Minnesota

    NASA Technical Reports Server (NTRS)

    Barnett, T. L. (Principal Investigator)

    1981-01-01

    The Williams-type yield model is based on multiple regression analysis of historial time series data at CRD level pooled to regional level (groups of similar CRDs). Basic variables considered in the analysis include USDA yield, monthly mean temperature, monthly precipitation, soil texture and topographic information, and variables derived from these. Technologic trend is represented by piecewise linear and/or quadratic functions of year. Indicators of yield reliability obtained from a ten-year bootstrap test (1970-1979) demonstrate that biases are small and performance based on root mean square appears to be acceptable for the intended AgRISTARS large area applications. The model is objective, adequate, timely, simple, and not costly. It consideres scientific knowledge on a broad scale but not in detail, and does not provide a good current measure of modeled yield reliability.

  11. Combined photoacoustic and magneto-acoustic imaging.

    PubMed

    Qu, Min; Mallidi, Srivalleesha; Mehrmohammadi, Mohammad; Ma, Li Leo; Johnston, Keith P; Sokolov, Konstantin; Emelianov, Stanislav

    2009-01-01

    Ultrasound is a widely used modality with excellent spatial resolution, low cost, portability, reliability and safety. In clinical practice and in the biomedical field, molecular ultrasound-based imaging techniques are desired to visualize tissue pathologies, such as cancer. In this paper, we present an advanced imaging technique - combined photoacoustic and magneto-acoustic imaging - capable of visualizing the anatomical, functional and biomechanical properties of tissues or organs. The experiments to test the combined imaging technique were performed using dual, nanoparticle-based contrast agents that exhibit the desired optical and magnetic properties. The results of our study demonstrate the feasibility of the combined photoacoustic and magneto-acoustic imaging that takes the advantages of each imaging techniques and provides high sensitivity, reliable contrast and good penetrating depth. Therefore, the developed imaging technique can be used in wide range of biomedical and clinical application.

  12. The development and validation of a custom built device for assessing frontal knee joint laxity.

    PubMed

    Ismail, Shiek Abdullah; Simic, Milena; Clarke, Jillian L; Lopes, Thiago Jambo Alves; Pappas, Evangelos

    2017-12-01

    This study reports the development and validation of a quantitative technique of assessing frontal knee joint laxity through a custom built device named KLICP. The objectives of this study were to determine: (i) the intra- and inter-rater reliability and (ii) the validity of the device when compared to real time ultrasound. Twenty-five participants had their frontal knee joint laxity assessed by the KLICP, by manual varus/valgus tests and by ultrasound. Two raters independently assessed laxity manually by three repeated measurements, repeated at least 48h later. Results were validated by comparing them to the medial and lateral joint space opening measured by the ultrasound. Intraclass correlation coefficients and standard error of measurement reliability were calculated. Pearson's correlation coefficients were calculated to determine the correlation between the KLICP and the joint space. Intra-rater reliability (intra-session) for each rater was good on both sessions (0.91-0.98), intra-rater reliability (inter-sessions) was moderate to good (0.62-0.87), and inter-rater reliability (intra-session) was good (0.75-0.80). There is low agreement for intra-rater (inter-session) and for inter-rater (intra-session) reliability. The KLICP measurement has a significant positive fair to moderate correlation to the ultrasound measurement at the left (r: 0.61, p: 0.01) and right (r: 0.48, p: 0.02) knee in the valgus direction and at the left (r: 0.51, p: 0.01) and right (r: 0.39, p: 0.05) knee in the varus direction. There is low agreement between the KLICP and the RTU. Reliability and agreement was good only when measured for intra-rater, within session. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Psychometric properties of a revised version of the Assisting Hand Assessment (Kids-AHA 5.0).

    PubMed

    Holmefur, Marie M; Krumlinde-Sundholm, Lena

    2016-06-01

    The aim of this study was to scrutinize the Assisting Hand Assessment (AHA) version 4.4 for possible improvements and to evaluate the psychometric properties regarding internal scale validity and aspects of reliability of a revised version of the AHA. In collaboration with experts, scoring criteria were changed for four items, and one fully new item was constructed. Twenty-two original, one new, and four revised items were scored for 164 assessments of children with unilateral cerebral palsy aged 18 months to 12 years. Rasch measurement analysis was used to evaluate internal scale validity by exploring rating-scale functioning, item and person goodness-of-fit, and principal component analysis. Targeting and scale reliability were also evaluated. After removal of misfitting items, a 20-item scale showed satisfactory goodness-of-fit. Unidimensionality was confirmed by principal component analysis. The rating scale functioned well for the 20 items, and the item difficulty was well suited to the ability level of the sample. The person reliability coefficient was 0.98, indicating high separation ability of the scale. A conversion table of AHA scores between the previous version (4.4) and the new version (5.0) was constructed. The new, 20-item version of the Kids-AHA (version 5.0), demonstrated excellent internal scale validity, suggesting improved responsiveness to changes and shortened scoring time. For comparison of scores from version 4.4 to 5.0, a transformation table is presented. © 2015 Mac Keith Press.

  14. Development of the Assessment of Belief Conflict in Relationship-14 (ABCR-14)

    PubMed Central

    Kyougoku, Makoto; Teraoka, Mutsumi; Masuda, Noriko; Ooura, Mariko; Abe, Yasushi

    2015-01-01

    Purpose Nurses and other healthcare workers frequently experience belief conflict, one of the most important, new stress-related problems in both academic and clinical fields. Methods In this study, using a sample of 1,683 nursing practitioners, we developed The Assessment of Belief Conflict in Relationship-14 (ABCR-14), a new scale that assesses belief conflict in the healthcare field. Standard psychometric procedures were used to develop and test the scale, including a qualitative framework concept and item-pool development, item reduction, and scale development. We analyzed the psychometric properties of ABCR-14 according to entropy, polyserial correlation coefficient, exploratory factor analysis, confirmatory factor analysis, average variance extracted, Cronbach’s alpha, Pearson product-moment correlation coefficient, and multidimensional item response theory (MIRT). Results The results of the analysis supported a three-factor model consisting of 14 items. The validity and reliability of ABCR-14 was suggested by evidence from high construct validity, structural validity, hypothesis testing, internal consistency reliability, and concurrent validity. The result of the MIRT offered strong support for good item response of item slope parameters and difficulty parameters. However, the ABCR-14 Likert scale might need to be explored from the MIRT point of view. Yet, as mentioned above, there is sufficient evidence to support that ABCR-14 has high validity and reliability. Conclusion The ABCR-14 demonstrates good psychometric properties for nursing belief conflict. Further studies are recommended to confirm its application in clinical practice. PMID:26247356

  15. [Validation of the Copenhagen Burnout Inventory to assess professional burnout in Spain].

    PubMed

    Molinero Ruiz, Emilia; Basart Gómez-Quintero, Helena; Moncada Lluis, Salvador

    2013-01-01

    The Copenhagen Burnout Inventory (CBI) is a public domain questionnaire measuring the degree of psychological fatigue experienced in three subdimensions of Burnout: personal (PB), work-related (WB), and client-related Burnout (CB). The study aimed to examine the acceptability, reliability and construct validity of the Spanish version of CBI. The study population consisted of 479 workers of educational centers, social work centres, healthcare centres and workers within the industry sector. Data was collected in 2009 through a self-administered questionnaire including the three CBI scales, sixteen scales of psychosocial work environment (COPSOQ ISTAS21) and perceived general and mental health and vitality (SF-36). Response rate was 78.7%. The three scales have an inter-item correlation average between 0.42 and 0.60 and a corrected item-total correlation between 0,49 and 0,83. The internal consistency of the three scales had Cronbach's α values of 0.90 for PB, 0.83 for WB and 0.82 for CB. Burnout was related to both psychosocial work environment and wellbeing measures in the expected direction and intensity. The items of the three scales show good discrimination capacity, good consistency and homogeneity. The three CBI scales have an acceptable internal consistency reliability index, slightly higher in PB. The discrimination capacity of the scales is verified through the discrimination index and the different levels between occupations and activities. These results demonstrate that the Spanish version of the CBI is a reliable and valid instrument for measuring Burnout.

  16. The Parent Trauma Response Questionnaire (PTRQ): development and preliminary validation.

    PubMed

    Williamson, Victoria; Hiller, Rachel M; Meiser-Stedman, Richard; Creswell, Cathy; Dalgleish, Tim; Fearon, Pasco; Goodall, Ben; McKinnon, Anna; Smith, Patrick; Wright, Isobel; Halligan, Sarah L

    2018-01-01

    Background : Following a child's experience of trauma, parental response is thought to play an important role in either facilitating or hindering their psychological adjustment. However, the ability to investigate the role of parenting responses in the post-trauma period has been hampered by a lack of valid and reliable measures. Objectives : The aim of this study was to design, and provide a preliminary validation of, the Parent Trauma Response Questionnaire (PTRQ), a self-report measure of parental appraisals and support for children's coping, in the aftermath of child trauma. Methods : We administered an initial set of 78 items to 365 parents whose children, aged 2-19 years, had experienced a traumatic event. We conducted principal axis factoring and then assessed the validity of the reduced measure against a standardized general measure of parental overprotection and via the measure's association with child post-trauma mental health. Results : Factor analysis generated three factors assessing parental maladaptive appraisals: (i) permanent change/damage, (ii) preoccupation with child's vulnerability, and (iii) self-blame. In addition, five factors were identified that assess parental support for child coping: (i) behavioural avoidance, (ii) cognitive avoidance, (iii) overprotection, (iv) maintaining pre-trauma routines, and (v) approach coping. Good validity was evidenced against the measure of parental overprotection and child post-traumatic stress symptoms. Good test-retest reliability of the measure was also demonstrated. Conclusions : The PTRQ is a valid and reliable self-report assessment of parenting cognitions and coping in the aftermath of child trauma.

  17. Improvement of carbon nanotube field emission properties by ultrasonic nanowelding

    NASA Astrophysics Data System (ADS)

    Zhao, Bo; Yadian, Boluo; Chen, Da; Xu, Dong; Zhang, Yafei

    2008-12-01

    Ultrasonic nanowelding was used to improve the field emission properties of carbon nanotube (CNT) cathodes. The CNTs were deposited on the Ti-coated glass substrate by electrophoretic deposition. By pressing CNTs against metal (Ti) substrate under a vibrating force at ultrasonic frequency, a reliable and low resistance contact was obtained between CNTs and Ti. The scanning electron microscopy results show that CNTs are embedded into the metal substrate and act as stable field emitters. The welded cathode demonstrates an excellent field emission with high emission current density and good current stability.

  18. An integrated algorithm for hypersonic fluid-thermal-structural numerical simulation

    NASA Astrophysics Data System (ADS)

    Li, Jia-Wei; Wang, Jiang-Feng

    2018-05-01

    In this paper, a fluid-structural-thermal integrated method is presented based on finite volume method. A unified integral equations system is developed as the control equations for physical process of aero-heating and structural heat transfer. The whole physical field is discretized by using an up-wind finite volume method. To demonstrate its capability, the numerical simulation of Mach 6.47 flow over stainless steel cylinder shows a good agreement with measured values, and this method dynamically simulates the objective physical processes. Thus, the integrated algorithm proves to be efficient and reliable.

  19. Laser induced fluorescence technique for environmental applications

    NASA Astrophysics Data System (ADS)

    Utkin, Andrei B.; Felizardo, Rui; Gameiro, Carla; Matos, Ana R.; Cartaxana, Paulo

    2014-08-01

    We discuss the development of laser induced fluorescence sensors and their application in the evaluation of water pollution and physiological status of higher plants and algae. The sensors were built on the basis of reliable and robust solid-state Nd:YAG lasers. They demonstrated good efficiency in: i) detecting and characterizing oil spills and dissolved organic matter; ii) evaluating the impact of stress on higher plants (cork oak, maritime pine, and genetically modified Arabidopsis); iii) tracking biomass changes in intertidal microphytobenthos; and iv) mapping macroalgal communities in the Tagus Estuary.

  20. Validity and Reliability of Farsi Version of Youth Sport Environment Questionnaire

    PubMed Central

    Eshghi, Mohammad Ali; Kordi, Ramin; Memari, Amir Hossein; Ghaziasgar, Ahmad; Mansournia, Mohammad-Ali; Zamani Sani, Seyed Hojjat

    2015-01-01

    The Youth Sport Environment Questionnaire (YSEQ) had been developed from Group Environment Questionnaire, a well-known measure of team cohesion. The aim of this study was to adapt and examine the reliability and validity of the Farsi version of the YSEQ. This version was completed by 455 athletes aged 13–17 years. Results of confirmatory factor analysis indicated that two-factor solution showed a good fit to the data. The results also revealed that the Farsi YSEQ showed high internal consistency, test-retest reliability, and good concurrent validity. This study indicated that the Farsi version of the YSEQ is a valid and reliable measure to assess team cohesion in sport setting. PMID:26464900

  1. International physical activity questionnaire: reliability and validity of the Turkish version.

    PubMed

    Saglam, Melda; Arikan, Hulya; Savci, Sema; Inal-Ince, Deniz; Bosnak-Guclu, Meral; Karabulut, Erdem; Tokgozoglu, Lale

    2010-08-01

    Physical inactivity is a global problem which is related to many chronic health disorders. Physical activity scales which allow cross-cultural comparisons have been developed. The goal was to assess the reliability and validity of a Turkish version of the International Physical Activity Questionnaire (IPAQ). 1,097 university students (721 women, 376 men; ages 18-32) volunteered. Short and long forms of the IPAQ gave good agreement and comparable 1-wk. test-retest reliabilities. Caltrac accelerometer data were compared with IPAQ scores in 80 participants with good agreement for short and long forms. Turkish versions of the IPAQ short and long forms are reliable and valid in assessment of physical activity.

  2. The Malay Version of the Perceived Stress Scale (PSS)-10 is a Reliable and Valid Measure for Stress among Nurses in Malaysia.

    PubMed

    Sandhu, Sukhvinder Singh; Ismail, Noor Hassim; Rampal, Krishna Gopal

    2015-11-01

    The Perceived Stress Scale-10 (PSS-10) is widely used to assess stress perception. The aim of this study was to translate the original PSS-10 into Malay and assess the reliability and validity of the Malay version among nurses. The Malay version of the PSS-10 was distributed among 229 nurses from four government hospitals in Selangor State. Test-retest reliability and concurrent validity was conducted with 25 nurses with the Malay version of the Depression Anxiety Stress Scales (DASS) 21. Cronbach's alpha, confirmatory factor analysis (CFA), intraclass correlation coefficient and Pearson's r correlation coefficient were used to determine the psychometric properties of the Malay PSS-10. Two factor components were yielded through exploratory factor analysis with eigenvalues of 3.37 and 2.10, respectively. Both of the factors accounted for 54.6% of the variance. CFA yielded a two-factor structure with satisfactory goodness-of-fit indices [x 2 /df = 2.43; comparative fit index (CFI) = 0.92, goodness-of-fit Index (GFI) = 0.94; standardised root mean square residual (SRMR) = 0.07 and root mean square error of approximation (RMSEA) = 0.08 (90% CI = 0.07-0.09)]. The Cronbach's alpha coefficient for the total items was 0.63 (0.82 for factor 1 and 0.72 for factor 2). The intraclass correlation coefficient (ICC) was 0.81 (95% CI: 0.62-0.91) for test-retest reliability testing after seven days. The total score and the negative component of the PSS-10 correlated significantly with the stress component of the DASS-21: (r = 0.61, P < 0.001) and (r = 0.56, P < 0.004), respectively. The Malay version of the PSS-10 demonstrated a satisfactory level of validity and reliability to assess stress perception. Therefore, this questionnaire is valid in assessing stress perception among nurses in Malaysia.

  3. Validation study of a Chinese version of Partners in Health in Hong Kong (C-PIH HK).

    PubMed

    Chiu, Teresa Mei Lee; Tam, Katharine Tai Wo; Siu, Choi Fong; Chau, Phyllis Wai Ping; Battersby, Malcolm

    2017-01-01

    The Partners in Health (PIH) scale is a measure designed to assess the generic knowledge, attitudes, behaviors, and impacts of self-management. A cross-cultural adaptation of the PIH for use in Hong Kong was evaluated in this study. This paper reports the validity and reliability of the Chinese version of PIH (C-PIH[HK]). A 12-item PIH was translated using forward-backward translation technique and reviewed by individuals with chronic diseases and health professionals. A total of 209 individuals with chronic diseases completed the scale. The construct validity, internal consistency, and test-retest reliability were evaluated in two waves. The findings in Wave 1 (n = 73) provided acceptable psychometric properties of the C-PIH(HK) but supported the adaptation of question 5 to improve the cultural relevance, validity, and reliability of the scale. An adapted version of C-PIH(HK) was evaluated in Wave 2. The findings in Wave 2 (n = 136) demonstrated good construct validity and internal consistency of C-PIH(HK). A principal component analysis with Oblimin rotation yielded a 3-factor solution, and the Cronbach's alphas of the subscales ranged from 0.773 to 0.845. Participants were asked whether they perceived the self-management workshops they attended and education provided by health professionals as useful or not. The results showed that the C-PIH(HK) was able to discriminate those who agreed and those who disagreed related to the usefulness of individual health education (p < 0.0001 in all subscales) and workshops (p < 0.001 in the knowledge subscale) as hypothesized. The test-retest reliability was high (ICC = 0.818). A culturally adapted version of PIH for use in Hong Kong was evaluated. The study supported good construct validity, discriminate validity, internal consistency, and test-retest reliability of the C-PIH(HK).

  4. Reliability and validity of the assessment of neurological soft-signs in children with and without attention-deficit-hyperactivity disorder.

    PubMed

    Gustafsson, Peik; Svedin, Carl Göran; Ericsson, Ingegerd; Lindén, Christian; Karlsson, Magnus K; Thernlund, Gunilla

    2010-04-01

    To study the value and reliability of an examination of neurological soft-signs, often used in Sweden, in the assessment of children with attention-deficit-hyperactivity disorder (ADHD), by examining children with and without ADHD, as diagnosed by an experienced clinician using the DSM-III-R. We have examined interrater reliability (26 males, nine females; age range 5y 6mo-11y), internal consistency (94 males, 43 females; age range 5y 6mo-11y), test-retest reliability (12 males, eight females; age range 6-9y), and validity (79 males, 33 females; age range 5y 6mo-9y). The sum of the scores for the items on the examination had good interrater reliability (intraclass correlation [ICC] 0.95) and acceptable internal consistency (Cronbach's alpha 0.76). The test-retest study also showed good reliability (ICC 0.91). There were modest associations between the examination and the assessment of motor function made by the physical education teacher (ICC 0.37) as well as from the parents' description (ICC 0.39). The examination of neurological soft-signs had a sensitivity of 0.80 and a specificity of 0.76 in predicting motor problems as evaluated by the physical education teacher. The reliability and validity of this examination seem to be good and can be recommended for clinical practice and research.

  5. Measurement Properties of the Psoriasis Symptom Inventory Electronic Daily Diary in Patients with Moderate to Severe Plaque Psoriasis.

    PubMed

    Viswanathan, Hema N; Mutebi, Alex; Milmont, Cassandra E; Gordon, Kenneth; Wilson, Hilary; Zhang, Hao; Klekotka, Paul A; Revicki, Dennis A; Augustin, Matthias; Kricorian, Gregory; Nirula, Ajay; Strober, Bruce

    2017-09-01

    The Psoriasis Symptom Inventory (PSI) is a patient-reported outcome instrument that measures the severity of psoriasis signs and symptoms. This study evaluated measurement properties of the PSI in patients with moderate to severe plaque psoriasis. This secondary analysis used pooled data from a phase 3 brodalumab clinical trial (AMAGINE-1). Outcome measures included the PSI, Psoriasis Area and Severity Index (PASI), static Physician's Global Assessment (sPGA), psoriasis-affected body surface area, 36-item Short-Form Health Survey version 2, and the Dermatology Life Quality Index (DLQI). The PSI was evaluated for dimensionality, item performance, reliability (internal consistency and test-retest), construct validity, ability to detect change, and agreement between PSI response and response measures based on the PASI, sPGA, and DLQI. Results supported unidimensionality, good item fit, ordered responses, and PSI scoring. The PSI demonstrated reliability: baseline Cronbach's alpha ≥ 0.92 and intraclass correlation coefficients ≥ 0.95. Correlations between PSI total score and DLQI item 1 (r = 0.86), DLQI symptoms and feelings (r = 0.87), and 36-item Short-Form Health Survey version 2 bodily pain (r = -0.61) supported convergent validity. PSI scores differed significantly (P < 0.001) among severity groups based on the PASI (< 12/≥ 12), sPGA (0-1/2-3/4-5), body surface area (< 5%/5%-10%/> 10%), and DLQI (≤ 5/> 5) at weeks 8 and 12. At week 12, the PSI detected significant changes in severity based on PASI responses (< 50/50- < 75/≥ 75) and sPGA (0-1/≥ 2), and showed good agreement (k ≥ 0.66) between PSI response and PASI, sPGA, and DLQI responses. The PSI demonstrated excellent validity, reliability, and ability to detect change in the severity of psoriasis signs and symptoms. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  6. Quality of life in South East Asian patients who consult for dyspepsia: Validation of the short form Nepean Dyspepsia Index

    PubMed Central

    Mahadeva, Sanjiv; Wee, Hwee-Lin; Goh, Khean-Lee; Thumboo, Julian

    2009-01-01

    Background Treatment objectives for dyspepsia include improvements in both symptoms and health-related quality of life (HRQoL). There is a lack of disease-specific instruments measuring HRQoL in South East Asian dyspeptics. Objectives To validate English and locally translated version of the Short-Form Nepean Dyspepsia Index (SF-NDI) in Malaysian patients who consult for dyspepsia. Methods The English version of the SF-NDI was culturally adapted locally and a Malay translation was developed using standard procedures. English and Malay versions of the SF-NDI were assessed against the SF-36 and the Leeds Dyspepsia Questionnaire (LDQ), examining internal consistency, test-retest reliability and construct validity. Results Pilot testing of the translated Malay and original English versions of the SF-NDI in twenty subjects did not identify any cross-cultural adaptation problems. 143 patients (86 English-speaking and 57 Malay speaking) with dyspepsia were interviewed and the overall response rate was 100% with nil missing data. The median total SF-NDI score for both languages were 72.5 and 60.0 respectively. Test-retest reliability was good with intraclass correlation coefficients of 0.90 (English) and 0.83 (Malay), while internal consistency of SF-NDI subscales revealed α values ranging from 0.83 – 0.88 (English) and 0.83 – 0.90 (Malay). In both languages, SF-NDI sub-scales and total score demonstrated lower values in patients with more severe symptoms and in patients with functional vs organic dyspepsia (known groups validity), although these were less marked in the Malay language version. There was moderate to good correlation (r = 0.3 – 0.6) between all SF-NDI sub-scales and various domains of the SF-36 (convergent validity). Conclusion This study demonstrates that both English and Malay versions of the SF-NDI are reliable and probably valid instruments for measuring HRQoL in Malaysian patients with dyspepsia. PMID:19463190

  7. The Imperial Paediatric Emergency Training Toolkit (IPETT) for use in paediatric emergency training: development and evaluation of feasibility and validity.

    PubMed

    Lambden, Simon; DeMunter, Claudine; Dowson, Anne; Cooper, Mehrengise; Gautama, Sanjay; Sevdalis, Nick

    2013-06-01

    To develop and test the feasibility, reliability, and validity of a practical toolkit for the assessment and feedback of skills required to manage paediatric emergencies in critical care settings. The Imperial Paediatric Emergency Training Toolkit (IPETT) was developed based on current evidence-base and expert input. IPETT assesses both technical and non-technical skills. The technical component covers skills in the areas of clinical assessment, airway and breathing, cardiovascular, and drugs. The non-technical component is based on the validated NOTECHS tool and covers communication and interaction, cooperation and team skills, leadership and managerial skills, and decision-making. The reliability (internal consistency), content validity (inter-correlations between different skills) and concurrent validity (correlations between global technical and non-technical scores) of IPETT were prospectively evaluated in 45 simulated paediatric crises carried out in a PICU with anaesthetic and paediatric trainees (N=52). Non-parametric analyses were carried out. Significance was set at P<0.05. Cronbach alpha reliability coefficients were overall acceptable for the technical (alpha range=0.638-0.810) and good for the non-technical (alpha range=0.701-0.899) component of IPETT. The median inter-skill correlation was rho=0.564 and rho=0.549 for the technical and non-technical components, respectively. These indicate good content validity, as the skills were inter-related but not redundant. We also demonstrate a correlation between the global technical and non-technical scores (rho=0.471) - all Ps<0.05 during the assessments. IPETT offers a psychometrically viable and feasible to use tool in the context of paediatric emergencies training. This study shows that assessment of technical and non-technical skills in combination may offer a more clinically relevant model for training in paediatric emergencies. Further validation should aim to demonstrate skill retention over time and skill transfer from simulation-based training to real emergencies. Copyright © 2013. Published by Elsevier Ireland Ltd.

  8. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    PubMed

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  9. Psychometric Properties of the Adapted Skillstreaming Checklist for High-Functioning Children with ASD

    ERIC Educational Resources Information Center

    Lopata, Christopher; Rodgers, Jonathan D.; Donnelly, James P.; Thomeer, Marcus L.; McDonald, Christin A.; Volker, Martin A.

    2017-01-01

    This study examined the reliability and criterion-related validity of parent ratings on the Adapted Skillstreaming Checklist (ASC) for a sample of 275 high-functioning children, ages 6-12 years, with ASD. Internal consistency for the total sample was 0.92. For two subsamples, test-retest reliability was very good at the 6-week and good at the…

  10. Cardiopulmonary exercise testing early after stroke using feedback-controlled robotics-assisted treadmill exercise: test-retest reliability and repeatability.

    PubMed

    Stoller, Oliver; de Bruin, Eling D; Schindelholz, Matthias; Schuster-Amft, Corina; de Bie, Rob A; Hunt, Kenneth J

    2014-10-11

    Exercise capacity is seriously reduced after stroke. While cardiopulmonary assessment and intervention strategies have been validated for the mildly and moderately impaired populations post-stroke, there is a lack of effective concepts for stroke survivors suffering from severe motor limitations. This study investigated the test-retest reliability and repeatability of cardiopulmonary exercise testing (CPET) using feedback-controlled robotics-assisted treadmill exercise (FC-RATE) in severely motor impaired individuals early after stroke. 20 subjects (age 44-84 years, <6 month post-stroke) with severe motor limitations (Functional Ambulatory Classification 0-2) were selected for consecutive constant load testing (CLT) and incremental exercise testing (IET) within a powered exoskeleton, synchronised with a treadmill and a body weight support system. A manual human-in-the-loop feedback system was used to guide individual work rate levels. Outcome variables focussed on standard cardiopulmonary performance parameters. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean difference, limits of agreement, and coefficient of variation (CoV) were estimated to assess repeatability. Peak performance parameters during IET yielded good to excellent relative reliability: absolute peak oxygen uptake (ICC =0.82), relative peak oxygen uptake (ICC =0.72), peak work rate (ICC =0.91), peak heart rate (ICC =0.80), absolute gas exchange threshold (ICC =0.91), relative gas exchange threshold (ICC =0.88), oxygen cost of work (ICC =0.87), oxygen pulse at peak oxygen uptake (ICC =0.92), ventilation rate versus carbon dioxide output slope (ICC =0.78). For these variables, SEM was 4-13%, MDC 12-36%, and CoV 0.10-0.36. CLT revealed high mean differences and insufficient test-retest reliability for all variables studied. This study presents first evidence on reliability and repeatability for CPET in severely motor impaired individuals early after stroke using a feedback-controlled robotics-assisted treadmill. The results demonstrate good to excellent test-retest reliability and appropriate repeatability for the most important peak cardiopulmonary performance parameters. These findings have important implications for the design and implementation of cardiovascular exercise interventions in severely impaired populations. Future research needs to develop advanced control strategies to enable the true limit of functional exercise capacity to be reached and to further assess test-retest reliability and repeatability in larger samples.

  11. Development and validation of an objective instrument to measure surgical performance at tonsillectomy.

    PubMed

    Roberson, David W; Kentala, Erna; Forbes, Peter

    2005-12-01

    The goals of this project were 1) to develop and validate an objective instrument to measure surgical performance at tonsillectomy, 2) to assess its interobserver and interobservation reliability and construct validity, and 3) to select those items with best reliability and most independent information to design a simplified form suitable for routine use in otolaryngology surgical evaluation. Prospective, observational data collection for an educational quality improvement project. The evaluation instrument was based on previous instruments developed in general surgery with input from attending otolaryngologic surgeons and experts in medical education. It was pilot tested and subjected to iterative improvements. After the instrument was finalized, a total of 55 tonsillectomies were observed and scored during academic year 2002 to 2003: 45 cases by residents at different points during their rotation, 5 by fellows, and 5 by faculty. Results were assessed for interobserver reliability, interobservation reliability, and construct validity. Factor analysis was used to identify items with independent information. Interobserver and interobservation reliability was high. On technical items, faculty substantially outperformed fellows, who in turn outperformed residents (P < .0001 for both comparisons). On the "global" scale (overall assessment), residents improved an average of 1 full point (on a 5 point scale) during a 3 month rotation (P = .01). In the subscale of "patient care," results were less clear cut: fellows outperformed residents, who in turn outperformed faculty, but only the fellows to faculty comparison was statistically significant (P = .04), and residents did not clearly improve over time (P = .36). Factor analysis demonstrated that technical items and patient care items factor separately and thus represent separate skill domains in surgery. It is possible to objectively measure surgical skill at tonsillectomy with high reliability and good construct validity. Factor analysis demonstrated that patient care is a distinct domain in surgical skill. Although the interobserver reliability for some patient care items reached statistical significance, it was not high enough for "high stakes testing" purposes. Using reliability and factor analysis results, we propose a simplified instrument for use in evaluating trainees in otolaryngologic surgery.

  12. Pilot testing of SHRP 2 reliability data and analytical products: Washington.

    DOT National Transportation Integrated Search

    2014-07-30

    The second Strategic Highway Research Program (SHRP 2) addresses the challenges of moving people and goods efficiently and safely on the nations highways. In its Reliability focus area, the research emphasizes improving the reliability of highway ...

  13. Pocket Handbook on Reliability

    DTIC Science & Technology

    1975-09-01

    exponencial distributions Weibull distribution, -xtimating reliability, confidence intervals, relia- bility growth, 0. P- curves, Bayesian analysis. 20 A S...introduction for those not familiar with reliability and a good refresher for those who are currently working in the area. LEWIS NERI, CHIEF...includes one or both of the following objectives: a) prediction of the current system reliability, b) projection on the system reliability for someI future

  14. Inter-Observer, Intra-Observer and Intra-Individual Reliability of Uroflowmetry Tests in Aged Men: A Generalizability Theory Approach.

    PubMed

    Liu, Ying-Buh; Yang, Stephen S; Hsieh, Cheng-Hsing; Lin, Chia-Da; Chang, Shang-Jen

    2014-05-01

    To evaluate the inter-observer, intra-observer and intra-individual reliability of uroflowmetry and post-void residual urine (PVR) tests in adult men. Healthy volunteers aged over 40 years were enrolled. Every participant underwent two sets of uroflowmetry and PVR tests with a 2-week interval between the tests. The uroflowmetry tests were interpreted by four urologists independently. Uroflowmetry curves were classified as bell-shaped, bell-shaped with tail, obstructive, restrictive, staccato, interrupted and tower-shaped and scored from 1 (highly abnormal) to 5 (absolutely normal). The agreements between the observers, interpretations and tests within individuals were analyzed using kappa statistics and intraclass correlation coefficients. Generalizability theory with decision analysis was used to determine how many observers, tests, and interpretations were needed to obtain an acceptable reliability (> 0.80). Of 108 volunteers, we randomly selected the uroflowmetry results from 25 participants for the evaluation of reliability. The mean age of the studied adults was 55.3 years. The intra-individual and intra-observer reliability on uroflowmetry tests ranged from good to very good. However, the inter-observer reliability on normalcy and specific type of flow pattern were relatively lower. In generalizability theory, three observers were needed to obtain an acceptable reliability on normalcy of uroflow pattern if the patient underwent uroflowmetry tests twice with one observation. The intra-individual and intra-observer reliability on uroflowmetry tests were good while the inter-observer reliability was relatively lower. To improve inter-observer reliability, the definition of uroflowmetry should be clarified by the International Continence Society. © 2013 Wiley Publishing Asia Pty Ltd.

  15. On the reliability of seasonal climate forecasts

    PubMed Central

    Weisheimer, A.; Palmer, T. N.

    2014-01-01

    Seasonal climate forecasts are being used increasingly across a range of application sectors. A recent UK governmental report asked: how good are seasonal forecasts on a scale of 1–5 (where 5 is very good), and how good can we expect them to be in 30 years time? Seasonal forecasts are made from ensembles of integrations of numerical models of climate. We argue that ‘goodness’ should be assessed first and foremost in terms of the probabilistic reliability of these ensemble-based forecasts; reliable inputs are essential for any forecast-based decision-making. We propose that a ‘5’ should be reserved for systems that are not only reliable overall, but where, in particular, small ensemble spread is a reliable indicator of low ensemble forecast error. We study the reliability of regional temperature and precipitation forecasts of the current operational seasonal forecast system of the European Centre for Medium-Range Weather Forecasts, universally regarded as one of the world-leading operational institutes producing seasonal climate forecasts. A wide range of ‘goodness’ rankings, depending on region and variable (with summer forecasts of rainfall over Northern Europe performing exceptionally poorly) is found. Finally, we discuss the prospects of reaching ‘5’ across all regions and variables in 30 years time. PMID:24789559

  16. The development of an instrument to match individuals with disabilities and service animals.

    PubMed

    Zapf, S A; Rough, R B

    There has been an increase in the use of service animals assisting persons with disabilities in the past decade. However many of the service dog agencies do not utilize an assessment that is designed to match the person to the animal in the rehabilitation and psycho-social domains. The purpose of this study was to develop the Service Animal Adaptive Intervention Assessment (SAAIA) and to measure the content validity, inter-rater reliability and clinical utility of the assessment. Two subject groups were used. Subject group one had 43 subjects who measured the content validity and clinical utility of the SAAIA Survey. Subject group two had 12 subjects who measured the inter-rater reliability by completing the SAAIA using information obtained through a video-taped client case scenario. Content validity results indicated a good to high percentage of agreement and a fair percentage of agreement for clinical utility. Inter-rater reliability results indicate good to high agreement on six of the eight variables of the SAAIA. However, the Kappa score indicates low inter-rater reliability. Results indicate the SAAIA has good content validity and inter-rater reliability and fair clinical utility based on percent agreement. However, further research is needed on the reliability of the SAAIA.

  17. Psychometric properties of the Arabic version of the 12-item diabetes fatalism scale

    PubMed Central

    Abi Kharma, Joelle

    2018-01-01

    Background There are widespread fatalistic beliefs in Arab countries, especially among individuals with diabetes. However, there is no tool to assess diabetes fatalism in this population. This study describes the processes used to create an Arabic version of the Diabetes Fatalism Scale (DFS) and examine its psychometric properties. Methods A descriptive correlational design was used with a convenience sample of Lebanese adults (N = 274) with type 2 diabetes recruited from a major hospital in Beirut, Lebanon and by snowball sampling. The 12- item Diabetes Fatalism Scale- Arabic (12-item DFS-Ar) was back-translated from the original version, pilot tested on 22 adults with type 2 diabetes and then administered to 274 patients to assess the validity and reliability of the scale. Confirmatory factor analysis (CFA) was used to test the hypothesized factor structure. Cronbach’s alpha was used to test for reliability. Results CFA supported the existence of the three factor hypothesis of the original DFS scale. The five items measuring “emotional distress” loaded under Factor 1, the four items measuring “spiritual coping” loaded under factor 2 and the last three items measuring “perceived self-efficacy” of the original scale loaded under Factor 3 (p <0.001 for all three subscales). Goodness of fit indices confirmed adequateness of the CFA model (CFI = 0.97, TLI = 0.96, RMSEA = 0.067 and pclose = 0.05). The 12-item DFS-Ar showed good reliability (Cronbach’s alpha of 0.86) and significantly predicted HbA1c (β = 0.20, p < 0.01). After adjusting for the demographic characteristics and the number of diabetes comorbid conditions, the 12-item DFS-Ar score was independently associated with HbA1c in a multivariable model (β = 0.16, p < 0.05). Conclusions The 12-item DFS-Ar demonstrated good psychometric properties that are comparable to the original scale. It is a valid and reliable measure of diabetes fatalism. Further testing with larger and non-Lebanese Arabic population is needed. PMID:29324827

  18. Assessment of different methods to estimate bovine colostrum quality on farm.

    PubMed

    Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D

    2016-09-01

    To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.

  19. Combining Microdialysis and Electrophysiology in Cerebral Cortex to Delineate Functional Implications of Acetylcholine Gradients

    NASA Astrophysics Data System (ADS)

    Nelson, Kari L.

    The neuronal network in cerebral cortex is a dynamic system that can undergo changes in collective neural activity as the organism changes its behavior. For example, during sleep and quiet restful awake state, many neurons tend to fire together in synchrony. In contrast, during alert awake states, firing patterns of neurons tend to be more asynchronous, firing more independently. These changes in population-level synchrony are defined as changes in cortical state. Response to sensory input is state-dependent, i.e., change in cortical state can impact the sensory information processing in cortex and introduce trial-to-trial variability in response to the same repeated stimuli. How the brain maintains reliable perception in spite of such trial-to-trial variability is a longstanding important question in neuroscience research. This dissertation is centered on two hypotheses. The first hypothesis is that different parts of the cortex can be in different states simultaneously. The second hypothesis is that inhomogeneity in cortical states can benefit the system by enabling the cortical network to maintain reliable sensory detection. If one part of the system is in a state that is not good for detection, then another part of the system could be in a different state that is good for detection, thus compensating and maintaining good detection for the system as a whole. These hypotheses were tested on anesthetized rats and awake mice. In anesthetized rats, cholinergic neuromodulation via microdialysis (muD) probes was used to induce cortical state changes in the somatosensory barrel cortex. Changes in cortical state and response to whisker stimulus was recorded with a microelectrode array (MEA). In awake mice, nucleus basalis was optogenetically stimulated by inserting an optic fiber in basal forebrain and response to visual stimulus was analyzed. The results demonstrated heterogeneity in cortical state across the spatial extent of cortical network. Changes in sensory response followed this heterogeneity and sensory detection was not reliable at the level of single neurons or small regions of cortex. The greater population of neurons, on the other hand, maintained reliable sensory detection, suggesting that heterogeneous state can be functionally beneficial for the cortical network.

  20. Reliability and Validity of Assessing User Satisfaction With Web-Based Health Interventions

    PubMed Central

    Lehr, Dirk; Reis, Dorota; Vis, Christiaan; Riper, Heleen; Berking, Matthias; Ebert, David Daniel

    2016-01-01

    Background The perspective of users should be taken into account in the evaluation of Web-based health interventions. Assessing the users’ satisfaction with the intervention they receive could enhance the evidence for the intervention effects. Thus, there is a need for valid and reliable measures to assess satisfaction with Web-based health interventions. Objective The objective of this study was to analyze the reliability, factorial structure, and construct validity of the Client Satisfaction Questionnaire adapted to Internet-based interventions (CSQ-I). Methods The psychometric quality of the CSQ-I was analyzed in user samples from 2 separate randomized controlled trials evaluating Web-based health interventions, one from a depression prevention intervention (sample 1, N=174) and the other from a stress management intervention (sample 2, N=111). At first, the underlying measurement model of the CSQ-I was analyzed to determine the internal consistency. The factorial structure of the scale and the measurement invariance across groups were tested by multigroup confirmatory factor analyses. Additionally, the construct validity of the scale was examined by comparing satisfaction scores with the primary clinical outcome. Results Multigroup confirmatory analyses on the scale yielded a one-factorial structure with a good fit (root-mean-square error of approximation =.09, comparative fit index =.96, standardized root-mean-square residual =.05) that showed partial strong invariance across the 2 samples. The scale showed very good reliability, indicated by McDonald omegas of .95 in sample 1 and .93 in sample 2. Significant correlations with change in depressive symptoms (r=−.35, P<.001) and perceived stress (r=−.48, P<.001) demonstrated the construct validity of the scale. Conclusions The proven internal consistency, factorial structure, and construct validity of the CSQ-I indicate a good overall psychometric quality of the measure to assess the user’s general satisfaction with Web-based interventions for depression and stress management. Multigroup analyses indicate its robustness across different samples. Thus, the CSQ-I seems to be a suitable measure to consider the user’s perspective in the overall evaluation of Web-based health interventions. PMID:27582341

  1. Reliability and Validity of Assessing User Satisfaction With Web-Based Health Interventions.

    PubMed

    Boß, Leif; Lehr, Dirk; Reis, Dorota; Vis, Christiaan; Riper, Heleen; Berking, Matthias; Ebert, David Daniel

    2016-08-31

    The perspective of users should be taken into account in the evaluation of Web-based health interventions. Assessing the users' satisfaction with the intervention they receive could enhance the evidence for the intervention effects. Thus, there is a need for valid and reliable measures to assess satisfaction with Web-based health interventions. The objective of this study was to analyze the reliability, factorial structure, and construct validity of the Client Satisfaction Questionnaire adapted to Internet-based interventions (CSQ-I). The psychometric quality of the CSQ-I was analyzed in user samples from 2 separate randomized controlled trials evaluating Web-based health interventions, one from a depression prevention intervention (sample 1, N=174) and the other from a stress management intervention (sample 2, N=111). At first, the underlying measurement model of the CSQ-I was analyzed to determine the internal consistency. The factorial structure of the scale and the measurement invariance across groups were tested by multigroup confirmatory factor analyses. Additionally, the construct validity of the scale was examined by comparing satisfaction scores with the primary clinical outcome. Multigroup confirmatory analyses on the scale yielded a one-factorial structure with a good fit (root-mean-square error of approximation =.09, comparative fit index =.96, standardized root-mean-square residual =.05) that showed partial strong invariance across the 2 samples. The scale showed very good reliability, indicated by McDonald omegas of .95 in sample 1 and .93 in sample 2. Significant correlations with change in depressive symptoms (r=-.35, P<.001) and perceived stress (r=-.48, P<.001) demonstrated the construct validity of the scale. The proven internal consistency, factorial structure, and construct validity of the CSQ-I indicate a good overall psychometric quality of the measure to assess the user's general satisfaction with Web-based interventions for depression and stress management. Multigroup analyses indicate its robustness across different samples. Thus, the CSQ-I seems to be a suitable measure to consider the user's perspective in the overall evaluation of Web-based health interventions.

  2. Validity and reliability of wii fit balance board for the assessment of balance of healthy young adults and the elderly.

    PubMed

    Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen

    2013-10-01

    [Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86-0.99) for the elderly people and positive correlations (r = 0.58-0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability.

  3. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study

    PubMed Central

    Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.

    2016-01-01

    Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049

  4. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study.

    PubMed

    Hashmi, Ali M; Naz, Shahana; Asif, Aftab; Khawaja, Imran S

    2016-01-01

    To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research.

  5. Validity and Reliability of Clinical Examination in the Diagnosis of Myofascial Pain Syndrome and Myofascial Trigger Points in Upper Quarter Muscles.

    PubMed

    Mayoral Del Moral, Orlando; Torres Lacomba, María; Russell, I Jon; Sánchez Méndez, Óscar; Sánchez Sánchez, Beatriz

    2017-12-15

    To determine whether two independent examiners can agree on a diagnosis of myofascial pain syndrome (MPS). To evaluate interexaminer reliability in identifying myofascial trigger points in upper quarter muscles. To evaluate the reliability of clinical diagnostic criteria for the diagnosis of MPS. To evaluate the validity of clinical diagnostic criteria for the diagnosis of MPS. Validity and reliability study. Provincial Hospital. Toledo, Spain. Twenty myofascial pain syndrome patients and 20 healthy, normal control subjects, enrolled by a trained and experienced examiner. Ten bilateral muscles from the upper quarter were evaluated by two experienced examiners. The second examiner was blinded to the diagnosis group. The MPS diagnosis required at least one muscle to have an active myofascial trigger point. Three to four days separated the two examinations. The primary outcome measure was the frequency with which the two examiners agreed on the classification of the subjects as patients or as healthy controls. The kappa statistic (K) was used to determine the level of agreement between both examinations, interpreted as very good (0.81-1.00), good (0.61-0.80), moderate (0.41-0.60), fair (0.21-0.40), or poor (≤0.20). Interexaminer reliability for identifying subjects with MPS was very good (K = 1.0). Interexaminer reliability for identifying muscles leading to a diagnosis of MPS was also very good (K = 0.81). Sensitivity and specificity showed high values for most examination tests in all muscles, which confirms the validity of clinical diagnostic criteria in the diagnosis of MPS. Interrater reliability between two expert examiners identifying subjects with MPS involving upper quarter muscles exhibited substantial agreement. These results suggest that clinical criteria can be valid and reliable in the diagnosis of this condition. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. PubMed Central

    Brown, J. B.; Schmidt, G.; Lent, B.; Sas, G.; Lemelin, J.

    2001-01-01

    OBJECTIVE: To replicate, in a Francophone community, our prior work determining the reliability and validity of the full Woman Abuse Screening Tool (WAST) and a two-item version (WAST-Short). DESIGN: Questionnaires completed by abused and nonabused women. SETTING: Two women's shelters in Francophone communities in Ontario and Quebec and participants' homes or workplaces. PARTICIPANTS: A convenience sample of 25 abused women currently residing in two women's shelters and a convenience sample of 21 women who reported they were not abused. MAIN OUTCOME MEASURES: Women's responses to French versions of the WAST, the Abuse Risk Inventory (ARI), and comfort in answering the questions were compared. Also, the reliability and validity of French versions of WAST and WAST-Short were assessed. RESULTS: Abused (n = 23) and not abused (n = 21) women were demographically similar. A strong single-factor structure that accounted for 81% of total variance in the French WAST items was identified. The French WAST was found to be highly reliable with a coefficient alpha of .95 and demonstrated construct and discriminant validity. The WAST-Short correctly classified all the nonabused women and 78.7% of the abused women. The abused women reported feeling less comfortable responding to the WAST questions than the nonabused women. CONCLUSION: The French version of the WAST demonstrated good reliability and validity and discriminated between known samples of abused and nonabused women. Even though the French WAST-Short did not perform as well as the English version, results of this study support further evaluation of the WAST for screening women in Francophone or bilingual family practice settings. PMID:11398732

  7. DJ-1 is a reliable serum biomarker for discriminating high-risk endometrial cancer.

    PubMed

    Di Cello, Annalisa; Di Sanzo, Maddalena; Perrone, Francesca Marta; Santamaria, Gianluca; Rania, Erika; Angotti, Elvira; Venturella, Roberta; Mancuso, Serafina; Zullo, Fulvio; Cuda, Giovanni; Costanzo, Francesco

    2017-06-01

    New reliable approaches to stratify patients with endometrial cancer into risk categories are highly needed. We have recently demonstrated that DJ-1 is overexpressed in endometrial cancer, showing significantly higher levels both in serum and tissue of patients with high-risk endometrial cancer compared with low-risk endometrial cancer. In this experimental study, we further extended our observation, evaluating the role of DJ-1 as an accurate serum biomarker for high-risk endometrial cancer. A total of 101 endometrial cancer patients and 44 healthy subjects were prospectively recruited. DJ-1 serum levels were evaluated comparing cases and controls and, among endometrial cancer patients, between high- and low-risk patients. The results demonstrate that DJ-1 levels are significantly higher in cases versus controls and in high- versus low-risk patients. The receiver operating characteristic curve analysis shows that DJ-1 has a very good diagnostic accuracy in discriminating endometrial cancer patients versus controls and an excellent accuracy in distinguishing, among endometrial cancer patients, low- from high-risk cases. DJ-1 sensitivity and specificity are the highest when high- and low-risk patients are compared, reaching the value of 95% and 99%, respectively. Moreover, DJ-1 serum levels seem to be correlated with worsening of the endometrial cancer grade and histotype, making it a reliable tool in the preoperative decision-making process.

  8. Development of a novel observational measure for anxiety in young children: The Anxiety Dimensional Observation Scale

    PubMed Central

    Mian, Nicholas D.; Carter, Alice S.; Pine, Daniel S.; Wakschlag, Lauren S.; Briggs-Gowan, Margaret J.

    2015-01-01

    Background Identifying anxiety disorders in preschool-age children represents an important clinical challenge. Observation is essential to clinical assessment and can help differentiate normative variation from clinically significant anxiety. Yet, most anxiety assessment methods for young children rely on parent-reports. The goal of this article is to present and preliminarily test the reliability and validity of a novel observational paradigm for assessing a range of fearful and anxious behaviors in young children, the Anxiety Dimensional Observation Schedule (Anx-DOS). Methods A diverse sample of 403 children, aged 3 to 6 years, and their mothers was studied. Reliability and validity in relation to parent reports (Preschool Age Psychiatric Assessment) and known risk factors, including indicators of behavioral inhibition (latency to touch novel objects) and attention bias to threat (in the dot-probe task) were investigated. Results The Anx-DOS demonstrated good inter-rater reliability and internal consistency. Evidence for convergent validity was demonstrated relative to mother-reported separation anxiety, social anxiety, phobic avoidance, trauma symptoms, and past service use. Finally, fearfulness was associated with observed latency and attention bias toward threat. Conclusions Findings support the Anx-DOS as a method for capturing early manifestations of fearfulness and anxiety in young children. Multimethod assessments incorporating standardized methods for assessing discrete, observable manifestations of anxiety may be beneficial for early identification and clinical intervention efforts. PMID:25773515

  9. Development and validation of The Personal Diabetes Questionnaire (PDQ): a measure of diabetes self-care behaviors, perceptions and barriers.

    PubMed

    Stetson, Barbara; Schlundt, David; Rothschild, Chelsea; Floyd, Jennifer E; Rogers, Whitney; Mokshagundam, Sri Prakash

    2011-03-01

    To develop and evaluate the validity and reliability of The Personal Diabetes Questionnaire (PDQ), a brief, yet comprehensive measure of diabetes self-care behaviors, perceptions and barriers. To examine individual items to provide descriptive and normative information and provide data on scale reliability and associations between PDQ scales and concurrently assessed HBA(1c) and BMI. Items were written to address nutritional management, medication utilization, blood glucose monitoring, and physical activity. The initial instrument was reviewed by multidisciplinary diabetes care providers and items subsequently revised until the measure provided complete coverage of the diabetes care domains using as few items as possible. The scoring scheme was generated rationally. Subjects were 790 adults (205 with type 1 and 585 with type 2 diabetes) who completed the PDQ while waiting for clinic appointments. Item completion rates were high, with few items skipped by participants. Subscales demonstrated good internal consistency (Cronbach α=.650-.834) and demonstrated significant associations with BMI (p ≤.001) and HbA(1c) (p ≤.001). The PDQ is a useful measure of diabetes self-care behaviors and related perceptions and barriers that is reliable and valid and feasible to administer in a clinic setting. This measure may be used to obtain data for assessing diabetes self-management and barriers and to guide patient care. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Development of the Mental Synthesis Evaluation Checklist (MSEC): A Parent-Report Tool for Mental Synthesis Ability Assessment in Children with Language Delay

    PubMed Central

    Braverman, Julia; Dunn, Rita

    2018-01-01

    Mental synthesis is the conscious purposeful process of synthesizing novel mental images from objects stored in memory. Mental synthesis ability is essential for understanding complex syntax, spatial prepositions, and verb tenses. In typical children, the timeline of mental synthesis acquisition is highly correlated with an increasing vocabulary. Children with Autism Spectrum Disorder (ASD), on the other hand, may learn hundreds of words but never acquire mental synthesis. In these individuals, tests assessing vocabulary comprehension may fail to demonstrate the profound deficit in mental synthesis. We developed a parent-reported Mental Synthesis Evaluation Checklist (MSEC) designed to assess mental synthesis acquisition in ASD children. The psychometric quality of MSEC was tested with 3715 parents of ASD children. Internal reliability of the 20-item MSEC was good (Cronbach’s alpha >0.9). MSEC exhibited adequate test–retest reliability; good construct validity, supported by a positive correlation with the Autism Treatment Evaluation Checklist (ATEC) Communication subscale; and good known group validity reflected by the difference in MSEC scores for children of different ASD severity levels. The MSEC questionnaire is copyright-free and can be used by researchers as a complimentary subscale for the ATEC evaluation. We hope that the addition of MSEC will make the combined assessment more sensitive to small steps in a child’s development. As MSEC does not rely on productive language, it may be an especially useful tool for assessing the development of nonverbal and minimally verbal children. PMID:29783788

  11. [Adaptation of the Hinting Task theory of the mind test to Spanish].

    PubMed

    Gil, David; Fernández-Modamio, Mar; Bengochea, Rosario; Arrieta, Marta

    2012-01-01

    Many studies have found that patients with schizophrenia have a deficit in theory of mind. Some authors associate this deficit with the presence of symptoms, while others maintain that it can also be observed in patients in the remission phase. There is no reference test to assess theory of mind in schizophrenia, although one of the most used is the Hinting Task. The aim of the present study consists of adapting and validating, in Spanish, the 10 histories that make up this test. The study was conducted on a sample of 39 control subjects and 40 patients with schizophrenia. The internal consistency and the between-observer reliability and test-retest were assessed in both sample groups. The performance of the patients and control subjects were also compared. Good reliability data was obtained in the inter-observer and test-retest in the two samples. On the other hand, the internal consistency was somewhat low for all of the 10 histories. For this reason, and starting from a previous study, a reduced version of 5 histories was prepared, which showed good internal consistency. The patients with schizophrenia obtained a significantly lower score than the control subjects in 8 out of the 10 histories. The reduced Spanish version of the Hinting Task demonstrated good psychometric properties. When compared to the control group, the patients with schizophrenia had a deficit in theory of mind. Copyright © 2011 SEP y SEPB. Published by Elsevier Espana. All rights reserved.

  12. Is laser speckle contrast analysis (LASCA) the new kid on the block in systemic sclerosis? A systematic literature review and pilot study to evaluate reliability of LASCA to measure peripheral blood perfusion in scleroderma patients.

    PubMed

    Cutolo, Maurizio; Vanhaecke, Amber; Ruaro, Barbara; Deschepper, Ellen; Ickinger, Claudia; Melsens, Karin; Piette, Yves; Trombetta, Amelia Chiara; De Keyser, Filip; Smith, Vanessa

    2018-06-06

    A reliable tool to evaluate flow is paramount in systemic sclerosis (SSc). We describe herein on the one hand a systematic literature review on the reliability of laser speckle contrast analysis (LASCA) to measure the peripheral blood perfusion (PBP) in SSc and perform an additional pilot study, investigating the intra- and inter-rater reliability of LASCA. A systematic search was performed in 3 electronic databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. In the pilot study, 30 SSc patients and 30 healthy subjects (HS) underwent LASCA assessment. Intra-rater reliability was assessed by having a first anchor rater performing the measurements at 2 time-points and inter-rater reliability by having the anchor rater and a team of second raters performing the measurements in 15 SSc and 30 HS. The measurements were repeated with a second anchor rater in the other 15 SSc patients, as external validation. Only 1 of the 14 records of interest identified through the systematic search was included in the final analysis. In the additional pilot study: intra-class correlation coefficient (ICC) for intra-rater reliability of the first anchor rater was 0.95 in SSc and 0.93 in HS, the ICC for inter-rater reliability was 0.97 in SSc and 0.93 in HS. Intra- and inter-rater reliability of the second anchor rater was 0.78 and 0.87. The identified literature regarding the reliability of LASCA measurements reports good to excellent inter-rater agreement. This very pilot study could confirm the reliability of LASCA measurements with good to excellent inter-rater agreement and found additionally good to excellent intra-rater reliability. Furthermore, similar results were found in the external validation. Copyright © 2018. Published by Elsevier B.V.

  13. Variation in the shape of the tibial insertion site of the anterior cruciate ligament: classification is required.

    PubMed

    Guenther, Daniel; Irarrázaval, Sebastian; Nishizawa, Yuichiro; Vernacchia, Cara; Thorhauer, Eric; Musahl, Volker; Irrgang, James J; Fu, Freddie H

    2017-08-01

    To propose a classification system for the shape of the tibial insertion site (TIS) of the anterior cruciate ligament (ACL) and to demonstrate the intra- and inter-rater agreement of this system. Due to variation in shape and size, different surgical approaches may be feasible to improve reconstruction of the TIS. One hundred patients with a mean age of 26 ± 11 years were included. The ACL was cut arthroscopically at the base of the tibial insertion site. Arthroscopic images were taken from the lateral and medial portal. Images were de-identified and duplicated. Two blinded observers classified the tibial insertion site according to a classification system. The tibial insertion site was classified as type I (elliptical) in 51 knees (51 %), type II (triangular) in 33 knees (33 %) and type III (C-shaped) in 16 knees (16 %). There was good agreement between raters when viewing the insertion site from the lateral portal (κ = 0.65) as well as from the medial portal (κ = 0.66). Intra-rater reliability was good to excellent. Agreement in the description of the insertion site between the medial and lateral portals was good for rater 1 and good for rater 2 (κ = 0.74 and 0.77, respectively). There is variation in the shape of the ACL TIS. The classification system is a repeatable and reliable tool to summarize the shape of the TIS using three common patterns. For clinical relevance, different shapes may require different types of reconstruction to ensure proper footprint restoration. Consideration of the individual TIS shape is required to prevent iatrogenic damage of adjacent structures like the menisci. III.

  14. Short-term stability of sleep and heart rate variability in good sleepers and patients with insomnia: for some measures, one night is enough.

    PubMed

    Israel, Benjamin; Buysse, Daniel J; Krafty, Robert T; Begley, Amy; Miewald, Jean; Hall, Martica

    2012-09-01

    Quantify the short-term stability of multiple indices of sleep and nocturnal physiology in good sleeper controls and primary insomnia patients. Intra-class correlation coefficients (ICC) were used to quantify the short-term stability of study outcomes. Sleep laboratory. Fifty-four adults with primary insomnia (PI) and 22 good sleeper controls (GSC). Visually scored sleep outcomes included indices of sleep duration, continuity, and architecture. Quantitative EEG outcomes included power in the delta, theta, alpha, sigma, and beta bands during NREM sleep. Power spectral analysis was used to estimate high-frequency heart rate variability (HRV) and the ratio of low- to high-frequency HRV power during NREM and REM sleep. With the exception of percent stage 3+4 sleep; visually scored sleep outcomes did not exhibit short-term stability across study nights. Most QEEG outcomes demonstrated short-term stability in both groups. Although power in the beta band was stable in the PI group (ICC = 0.75), it tended to be less stable in GSCs (ICC = 0.55). Both measures of cardiac autonomic tone exhibited short-term stability in GSCs and PIs during NREM and REM sleep. Most QEEG bandwidths and HRV during sleep show high short-term stability in good sleepers and patients with insomnia alike. One night of data is, thus, sufficient to derive reliable estimates of these outcomes in studies focused on group differences or correlates of QEEG and/or HRV. In contrast, one night of data is unlikely to generate reliable estimates of PSG-assessed sleep duration, continuity or architecture, with the exception of slow wave sleep.

  15. [Modification and evaluation of assessment of 
medication literacy].

    PubMed

    Zheng, Feng; Zhong, Zhuqing; Ding, Siqing; Luo, Aijing; Liu, Zina

    2016-11-28

    To translate and revise the Medication Literacy Assessment in English (MedLitRxSE-English) and evaluate its validity and reliability.
 Methods: We introduced MedLitRxSE-English from abroad. According to the principles of Brislin and culture adjustment, we revised it as a Chinese edition. Using random sampling method, from Oct, 2014 to Jan, 2015, 461 non-hospitalized patients from the outpatient departments of the top three hospitals in Changsha city were investigated. The reliability and validity of the scale was tested.
 Results: The test-retest reliability of the Chinese version for medication literacy scale was 0.885; the split reliability was 0.840; K-R was 0.820; the correlations between the assessment of medication literacy and the corresponding items were 0.427-0.587; the confirmatory factor analysis revealed overall good fit. Root mean square error of approximation (RMSEA), χ2/df, goodness of fit index (GFI) and comparative fit index (CFI) was 0.08, 3.06, 0.91 and 0.94, respectively. 
 Conclusion: The Chinese version for the assessment of medication literacy is in good reliability and validity, and it can be used to evaluate the medication literacy in our country.

  16. Validation of the geriatric anxiety inventory in a duloxetine clinical trial for elderly adults with generalized anxiety disorder.

    PubMed

    Ball, Susan G; Lipsius, Sarah; Escobar, Rodrigo

    2015-09-01

    The Generalized Anxiety Inventory (GAI) has been developed for use in the assessment of anxiety symptoms in older adults (≥ 65 years), but previous validation work has not examined the psychometric qualities of the instrument in relation to treatment. The objective of this study was to examine the performance of the GAI for its internal reliability, convergent and divergent validity, and its sensitivity to treatment. Elderly patients with generalized anxiety disorder (GAD) participated in a 10-week double-blind study of duloxetine treatment for patients with GAD. Anxiety symptoms were assessed with the Hamilton Anxiety Rating Scale (HAMA), the Hospital Anxiety and Depression Scale (HADS) anxiety and depression subscales, and the GAI. Internal reliability of the GAI was assessed with Cronbach's α. Correlations among the HAMA, HADS, and GAI scores were analyzed to determine convergent and divergent validity. Patients were also compared on remission status using recommended cut-off scores for the GAI. Patients with GAD, who were at least 65 years of age, were randomly assigned to double-blind treatment with either duloxetine (N = 151) or placebo (N = 140) for 10 weeks acute therapy. The mean change on the GAI was significantly greater with duloxetine compared with placebo treatment (-8.36 vs. -4.96, respectively, p ≤ 0.001). The GAI demonstrated good internal consistency, good convergent and divergent validity, but suggested cut-off values for caseness with the GAI did not correspond to remission status as measured by the HAMA. Within an elderly patient population with GAD, the GAI demonstrated sound psychometric qualities and sensitivity to change with treatment.

  17. The Effect of Ag and Ag+N Ion Implantation on Cell Attachment Properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Urkac, Emel Sokullu; Oztarhan, Ahmet; Gurhan, Ismet Deliloglu

    2009-03-10

    Implanted biomedical prosthetic devices are intended to perform safely, reliably and effectively in the human body thus the materials used for orthopedic devices should have good biocompatibility. Ultra High Molecular Weight Poly Ethylene (UHMWPE) has been commonly used for total hip joint replacement because of its very good properties. In this work, UHMWPE samples were Ag and Ag+N ion implanted by using the Metal-Vapor Vacuum Arc (MEVVA) ion implantation technique. Samples were implanted with a fluency of 1017 ion/cm2 and extraction voltage of 30 kV. Rutherford Backscattering Spectrometry (RBS) was used for surface studies. RBS showed the presence of Agmore » and N on the surface. Cell attachment properties investigated with model cell lines (L929 mouse fibroblasts) to demonstrate that the effect of Ag and Ag+N ion implantation can favorably influence the surface of UHMWPE for biomedical applications. Scanning electron microscopy (SEM) was used to demonstrate the cell attachment on the surface. Study has shown that Ag+N ion implantation represents more effective cell attachment properties on the UHMWPE surfaces.« less

  18. Assessing motivation to change in bulimia nervosa: the Bulimia Nervosa Stages of Change Questionnaire.

    PubMed

    Martinez, Esteve; Castro, Josefina; Bigorra, Aitana; Morer, Astrid; Calvo, Rosa; Vila, Montserrat; Toro, Josep; Rieger, Elisabeth

    2007-01-01

    To assess motivation to change in adolescent patients with bulimia nervosa through the Bulimia Nervosa Stages of Change Questionnaire (BNSOCQ), an instrument adapted from the Anorexia Nervosa Stages of Change Questionnaire (ANSOCQ) already validated in anorexic patients. Subjects were 30 bulimia nervosa patients (mean age = 16.3 years) who were receiving treatment at an eating disorders unit. The evaluation instruments were: the BNSOCQ, the Eating Disorders Inventory (EDI-2) and the Beck Depression Inventory (BDI). The BNSOCQ was re-administered 1 week later to evaluate test-retest reliability. The BNSOCQ demonstrated good internal consistency (Cronbach's alpha = 0.94) and one week test-retest reliability (Pearson's r = 0.93). Negative significant correlations were found between the BNSOCQ and several EDI-2 scales (Pearson's r between -0.51 and -0.84) and the BDI (r = -0.74). The study provides initial support for the reliability and validity of the BNSOCQ as a self-report instrument for assessing motivation to change in adolescents with bulimia nervosa. 2006 John Wiley & Sons, Ltd and Eating Disorders Association

  19. Answering the call: a tool that measures functional breast cancer literacy.

    PubMed

    Williams, Karen Patricia; Templin, Thomas N; Hines, Resche D

    2013-01-01

    There is a need for health care providers and health care educators to ensure that the messages they communicate are understood. The purpose of this research was to test the reliability and validity, in a culturally diverse sample of women, of a revised Breast Cancer Literacy Assessment Tool (Breast-CLAT) designed to measure functional understanding of breast cancer in English, Spanish, and Arabic. Community health workers verbally administered the 35-item Breast-CLAT to 543 Black, Latina, and Arab American women. A confirmatory factor analysis using a 2-parameter item response theory model was used to test the proposed 3-factor Breast-CLAT (awareness, screening and knowledge, and prevention and control). The confirmatory factor analysis using a 2-parameter item response theory model had a good fit (TLI = .91, RMSEA = .04) to the proposed 3-factor structure. The total scale reliability ranged from .80 for Black participants to .73 for total culturally diverse sample. The three subscales were differentially predictive of family history of cancer. The revised Breast-CLAT scales demonstrated internal consistency reliability and validity in this multiethnic, community-based sample.

  20. Beyond semantic accuracy: preschoolers evaluate a speaker's reasons.

    PubMed

    Koenig, Melissa A

    2012-01-01

    Children's sensitivity to the quality of epistemic reasons and their selective trust in the more reasonable of 2 informants was investigated in 2 experiments. Three-, 4-, and 5-year-old children (N = 90) were presented with speakers who stated different kinds of evidence for what they believed. Experiment 1 showed that children of all age groups appropriately judged looking, reliable testimony, and inference as better reasons for belief than pretense, guessing, and desiring. Experiment 2 showed that 3- and 4-year-old children preferred to seek and accept new information from a speaker who was previously judged to use the "best" way of thinking. The findings demonstrate that children distinguish certain good from bad reasons and prefer to learn from those who showcased good reasoning in the past. © 2012 The Author. Child Development © 2012 Society for Research in Child Development, Inc.

  1. Reliability and criterion validity of two applications of the iPhone™ to measure cervical range of motion in healthy participants

    PubMed Central

    2013-01-01

    Summary of background data Recent smartphones, such as the iPhone, are often equipped with an accelerometer and magnetometer, which, through software applications, can perform various inclinometric functions. Although these applications are intended for recreational use, they have the potential to measure and quantify range of motion. The purpose of this study was to estimate the intra and inter-rater reliability as well as the criterion validity of the clinometer and compass applications of the iPhone in the assessment cervical range of motion in healthy participants. Methods The sample consisted of 28 healthy participants. Two examiners measured cervical range of motion of each participant twice using the iPhone (for the estimation of intra and inter-reliability) and once with the CROM (for the estimation of criterion validity). Estimates of reliability and validity were then established using the intraclass correlation coefficient (ICC). Results We observed a moderate intra-rater reliability for each movement (ICC = 0.65-0.85) but a poor inter-rater reliability (ICC < 0.60). For the criterion validity, the ICCs are moderate (>0.50) to good (>0.65) for movements of flexion, extension, lateral flexions and right rotation, but poor (<0.50) for the movement left rotation. Conclusion We found good intra-rater reliability and lower inter-rater reliability. When compared to the gold standard, these applications showed moderate to good validity. However, before using the iPhone as an outcome measure in clinical settings, studies should be done on patients presenting with cervical problems. PMID:23829201

  2. Stability of person ability measures in people with acquired brain injury in the use of everyday technology: the test-retest reliability of the Management of Everyday Technology Assessment (META).

    PubMed

    Malinowsky, Camilla; Kassberg, Ann-Charlotte; Larsson-Lund, Maria; Kottorp, Anders

    2016-01-01

    To evaluate the test-retest reliability of the Management of Everyday Technology Assessment (META) in a sample of people with acquired brain injury (ABI). The META was administered twice within a two-week period to 25 people with ABI. A Rasch measurement model was used to convert the META ordinal raw scores into equal-interval linear measures of each participant's ability to manage everyday technology (ET). Test-retest reliability of the stability of the person ability measures in the META was examined by a standardized difference Z-test and an intra-class correlations analysis (ICC 1). The results showed that the paired person ability measures generated from the META were stable over the test-retest period for 22 of the 25 subjects. The ICC 1 correlation was 0.63, which indicates good overall reliability. The META demonstrated acceptable test-retest reliability in a sample of people with ABI. The results illustrate the importance of using sufficiently challenging ETs (relative to a person's abilities) to generate stable META measurements over time. Implications for Rehabilitation The findings add evidence regarding the test-retest reliability of the person ability measures generated from the observation assessment META in a sample of people with ABI. The META might support professionals in the evaluation of interventions that are designed to improve clients' performance of activities including the ability to manage ET.

  3. Reliability of 3-Dimensional Measures of Single-Leg Cross Drop Landing Across 3 Different Institutions: Implications for Multicenter Biomechanical and Epidemiological Research on ACL Injury Prevention.

    PubMed

    DiCesare, Christopher A; Bates, Nathaniel A; Barber Foss, Kim D; Thomas, Staci M; Wordeman, Samuel C; Sugimoto, Dai; Roewer, Benjamin D; Medina McKeon, Jennifer M; Di Stasi, Stephanie; Noehren, Brian W; Ford, Kevin R; Kiefer, Adam W; Hewett, Timothy E; Myer, Gregory D

    2015-12-01

    Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Controlled laboratory study. Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated.

  4. Reliability of 3-Dimensional Measures of Single-Leg Cross Drop Landing Across 3 Different Institutions

    PubMed Central

    DiCesare, Christopher A.; Bates, Nathaniel A.; Barber Foss, Kim D.; Thomas, Staci M.; Wordeman, Samuel C.; Sugimoto, Dai; Roewer, Benjamin D.; Medina McKeon, Jennifer M.; Di Stasi, Stephanie; Noehren, Brian W.; Ford, Kevin R.; Kiefer, Adam W.; Hewett, Timothy E.; Myer, Gregory D.

    2015-01-01

    Background: Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. Purpose: To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Study Design: Controlled laboratory study. Methods: Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Results: Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Conclusion: Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Clinical Relevance: Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated. PMID:26779550

  5. Reliability and Validity of a New Method for Isometric Back Extensor Strength Evaluation Using A Hand-Held Dynamometer

    PubMed Central

    2017-01-01

    Objective To investigate the reliability and validity of a new method for isometric back extensor strength measurement using a portable dynamometer. Methods A chair equipped with a small portable dynamometer was designed (Power Track II Commander Muscle Tester). A total of 15 men (mean age, 34.8±7.5 years) and 15 women (mean age, 33.1±5.5 years) with no current back problems or previous history of back surgery were recruited. Subjects were asked to push the back of the chair while seated, and their isometric back extensor strength was measured by the portable dynamometer. Test-retest reliability was assessed with intraclass correlation coefficient (ICC). For the validity assessment, isometric back extensor strength of all subjects was measured by a widely used physical performance evaluation instrument, BTE PrimusRS system. The limit of agreement (LoA) from the Bland-Altman plot was evaluated between two methods. Results The test-retest reliability was excellent (ICC=0.82; 95% confidence interval, 0.65–0.91). The Bland-Altman plots demonstrated acceptable agreement between the two methods: the lower 95% LoA was −63.1 N and the upper 95% LoA was 61.1 N. Conclusion This study shows that isometric back extensor strength measurement using a portable dynamometer has good reliability and validity. PMID:29201818

  6. Psychometric Properties of the Persian Version of Death Depression Scale-Revised in Iranian Patients with Acute Myocardial Infarction.

    PubMed

    Sharif Nia, Hamid; Pahlevan Sharif, Saeed; Lehto, Rebecca H; Allen, Kelly A; Goudarzian, Amir Hossein; Yaghoobzadeh, Ameneh; Soleimani, Mohammad Ali

    2017-07-01

    Objective: Limited research has examined the psychometric properties of death depression scales in Persian populations with cardiac disease despite the need for valid assessment tools for evaluating depressive symptoms in patients with life-limiting chronic conditions. The present study aimed at evaluating the reliability and validity of the Persian Version of Death Depression Scale - Revised (DDS-R) in Iranian patients who had recent acute myocardial infarction (AMI). Method: This psychometric study was conducted with a convenience sample of 407 patients with AMI diagnosis who completed the Persian version of the DDS-R. The face, content, and construct validity of the scale were ascertained. Internal consistency, test-retest, and construct reliability (CR) were used to assess reliability of the Persian Version of DDS-R. Results: Based on maximum likelihood exploratory factor analysis and consideration of conceptual meaning, a 4-factor solution was identified, explaining 75.89% of the total variance. Goodness-of-fit indices (GFI), Comparative Fit Index (CFI), Normed Fit Index (NFI), Incremental Fit Index (IFI), and Root Mean Square Error of Approximation (RMSEA) in the final DDS-R structure demonstrated the adequacy of the 4-domain structure. The internal consistency, construct reliability, and Intra-class Correlation Coefficients (ICC) were greater than .70. Conclusion: The DDS-R was found to be a valid and reliable assessment tool for evaluating death depression symptoms in Iranian patients with AMI.

  7. Cross-cultural adaptation, reliability, and validity of the Turkish version of the Cancer Fatigue Scale in patients with breast cancer

    PubMed

    Şahin, Sedef; Huri, Meral; Aran, Orkun Tahir; Uyanık, Mine

    2018-02-23

    Background/aim: The Cancer Fatigue Scale (CFS) was developed to evaluate the severity of fatigue in patients with breast cancer. The aim of this study is to translate and culturally adapt a Turkish version and investigate the validity and reliability of the CFS in Turkish patients with fatigue symptoms. Materials and methods: Eighty participants completed the Turkish version of the CFS for breast cancer and the European Organization for Research and Treatment of Cancer Quality of Life Core Questionnaire ″Core 30″ (EORTC QLQ-C30). Test-retest reliability was evaluated by repeating the CFS with a 7-day interval. Results: The CFS demonstrated high test-retest reliability (ICC = 0.95) and good internal consistency (Cronbach′s alpha = 0.74) for all domains. The Kaiser-Meyer-Olkin measure of sampling adequacy was found to be 0.819, which is considered to be satisfactory (>0.5). Correlations between domains of CFS physical and EORTC physical (r: 0.77), CFS cognitive and EORTC cognitive (r: 0.70), and CFS physical and EORTC fatigue (r: 0.80) were found to be significant. Conclusion: The Turkish version of the CFS is a reliable and valid instrument to assess physical, effective, and cognitive dimensions of fatigue. The CFS may be used to evaluate the severity of fatigue in Turkish-speaking breast cancer patients.

  8. Lifetime prediction and reliability estimation methodology for Stirling-type pulse tube refrigerators by gaseous contamination accelerated degradation testing

    NASA Astrophysics Data System (ADS)

    Wan, Fubin; Tan, Yuanyuan; Jiang, Zhenhua; Chen, Xun; Wu, Yinong; Zhao, Peng

    2017-12-01

    Lifetime and reliability are the two performance parameters of premium importance for modern space Stirling-type pulse tube refrigerators (SPTRs), which are required to operate in excess of 10 years. Demonstration of these parameters provides a significant challenge. This paper proposes a lifetime prediction and reliability estimation method that utilizes accelerated degradation testing (ADT) for SPTRs related to gaseous contamination failure. The method was experimentally validated via three groups of gaseous contamination ADT. First, the performance degradation model based on mechanism of contamination failure and material outgassing characteristics of SPTRs was established. Next, a preliminary test was performed to determine whether the mechanism of contamination failure of the SPTRs during ADT is consistent with normal life testing. Subsequently, the experimental program of ADT was designed for SPTRs. Then, three groups of gaseous contamination ADT were performed at elevated ambient temperatures of 40 °C, 50 °C, and 60 °C, respectively and the estimated lifetimes of the SPTRs under normal condition were obtained through acceleration model (Arrhenius model). The results show good fitting of the degradation model with the experimental data. Finally, we obtained the reliability estimation of SPTRs through using the Weibull distribution. The proposed novel methodology enables us to take less than one year time to estimate the reliability of the SPTRs designed for more than 10 years.

  9. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device.

    PubMed

    Jackson, Steven M; Cheng, M Samuel; Smith, A Russell; Kolber, Morey J

    2017-02-01

    Hand held dynamometry (HHD) is a more objective way to quantify muscle force production (MP) compared to traditional manual muscle testing. HHD reliability can be negatively impacted by both the strength of the tester and the subject particularly in the lower extremities due to larger muscle groups. The primary aim of this investigation was to assess intrarater reliability of HHD with use of a portable stabilization device for lower extremity MP in an athletic population. Isometric lower extremity strength was measured for bilateral lower extremities including hip abductors, external rotators, adductors, knee extensors, and ankle plantar flexors was measured in a sample of healthy recreational runners (8 male, 7 females, = 30 limbs) training for a marathon. These measurements were assessed using an intrasession intrarater reliability design. Intraclass correlation coefficients (ICC) were calculated using 3,1 model based on the single rater design. The standard error of measurement (SEM) for each muscle group was also calculated. ICC were excellent ranging from ICC (3,1) = 0.93-0.98 with standard error of measurements ranging from 0.58 to 17.2 N. This study establishes the use of a HHD with a portable stabilization device as demonstrating good reliability within testers for measuring lower extremity muscle performance in an active healthy population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Investigating the reliability and validity of the Dutch versions of the illness management and recovery scales among clients with mental disorders.

    PubMed

    Goossens, Peter J J; Beentjes, Titus A A; Knol, Suzanne; Salyers, Michelle P; de Vries, Sjoerd J

    2017-12-01

    The Illness Management and Recovery scales (IMRS) can measure the progress of clients' illness self-management and recovery. Previous studies have examined the psychometric properties of the IMRS. This study examined the reliability and validity of the Dutch version of the IMRS. Clients (n = 111) and clinicians (n = 40) completed the client and clinician versions of the IMRS, respectively. The scales were administered again 2 weeks later to assess stability over time. Validity was assessed with the Utrecht Coping List (UCL), Dutch Empowerment Scale (DES), and Brief Symptom Inventory (BSI). The client and clinician versions of the IMRS had moderate internal reliability, with α = 0.69 and 0.71, respectively. The scales showed strong test-retest reliability, r = 0.79, for the client version and r = 0.86 for the clinician version. Correlations between client and clinician versions ranged from r = 0.37 to 0.69 for the total and subscales. We also found relationships in expected directions between the client IMRS and UCL, DES and BSI, which supports validity of the Dutch version of the IMRS. The Dutch version of the IMRS demonstrated good reliability and validity. The IMRS could be useful for Dutch-speaking programs interested in evaluating client progress on illness self-management and recovery.

  11. The flaws and human harms of animal experimentation.

    PubMed

    Akhtar, Aysha

    2015-10-01

    Nonhuman animal ("animal") experimentation is typically defended by arguments that it is reliable, that animals provide sufficiently good models of human biology and diseases to yield relevant information, and that, consequently, its use provides major human health benefits. I demonstrate that a growing body of scientific literature critically assessing the validity of animal experimentation generally (and animal modeling specifically) raises important concerns about its reliability and predictive value for human outcomes and for understanding human physiology. The unreliability of animal experimentation across a wide range of areas undermines scientific arguments in favor of the practice. Additionally, I show how animal experimentation often significantly harms humans through misleading safety studies, potential abandonment of effective therapeutics, and direction of resources away from more effective testing methods. The resulting evidence suggests that the collective harms and costs to humans from animal experimentation outweigh potential benefits and that resources would be better invested in developing human-based testing methods.

  12. Validation of the quality of life in childhood epilepsy questionnaire in American epilepsy patients.

    PubMed

    Sabaz, Mark; Lawson, John A; Cairns, David R; Duchowny, Michael S; Resnick, Trevor J; Dean, Patricia M; Bye, Ann M E

    2003-12-01

    The aim of this study was to adapt the Australian Quality of Life in Childhood Epilepsy Questionnaire (QOLCE) and determine its psychometric properties in a North American population. Participants were North American families with children diagnosed with epilepsy. Parents were asked to complete the American QOLCE (USQOLCE) and the Child Health Questionnaire (CHQ). Seventy-one families completed the USQOLCE. The internal consistency reliability of the subscales was good. USQOLCE subscales correlated highly with theoretically similar subscales contained in the CHQ. Theoretically dissimilar subscales on the two instruments did not correlate as well. USQOLCE correlated significantly with a parental rating of seizure severity and an independent measure of degree of postoperative seizure control. This study demonstrated that the USQOLCE is suitable for a North American population with evidence of its reliability and validity including its sensitivity to seizure burden.

  13. Probabilistic thinking and death anxiety: a terror management based study.

    PubMed

    Hayslip, Bert; Schuler, Eric R; Page, Kyle S; Carver, Kellye S

    2014-01-01

    Terror Management Theory has been utilized to understand how death can change behavioral outcomes and social dynamics. One area that is not well researched is why individuals willingly engage in risky behavior that could accelerate their mortality. One method of distancing a potential life threatening outcome when engaging in risky behaviors is through stacking probability in favor of the event not occurring, termed probabilistic thinking. The present study examines the creation and psychometric properties of the Probabilistic Thinking scale in a sample of young, middle aged, and older adults (n = 472). The scale demonstrated adequate internal consistency reliability for each of the four subscales, excellent overall internal consistency, and good construct validity regarding relationships with measures of death anxiety. Reliable age and gender effects in probabilistic thinking were also observed. The relationship of probabilistic thinking as part of a cultural buffer against death anxiety is discussed, as well as its implications for Terror Management research.

  14. Development and validation of the coping with terror scale.

    PubMed

    Stein, Nathan R; Schorr, Yonit; Litz, Brett T; King, Lynda A; King, Daniel W; Solomon, Zahava; Horesh, Danny

    2013-10-01

    Terrorism creates lingering anxiety about future attacks. In prior terror research, the conceptualization and measurement of coping behaviors were constrained by the use of existing coping scales that index reactions to daily hassles and demands. The authors created and validated the Coping with Terror Scale to fill the measurement gap. The authors emphasized content validity, leveraging the knowledge of terror experts and groups of Israelis. A multistep approach involved construct definition and item generation, trimming and refining the measure, exploring the factor structure underlying item responses, and garnering evidence for reliability and validity. The final scale comprised six factors that were generally consistent with the authors' original construct specifications. Scores on items linked to these factors demonstrate good reliability and validity. Future studies using the Coping with Terror Scale with other populations facing terrorist threats are needed to test its ability to predict resilience, functional impairment, and psychological distress.

  15. Development and Validity Testing of the Worksite Health Index: An Assessment Tool to Help and Improve Korean Employees' Health-Related Outcome.

    PubMed

    Yun, Young Ho; Sim, Jin Ah; Lim, Ye Jin; Lim, Cheol Il; Kang, Sung-Choon; Kang, Joon-Ho; Park, Jun Dong; Noh, Dong Young

    2016-06-01

    The objective of this study was to develop the Worksite Health Index (WHI) and validate its psychometric properties. The development of the WHI questionnaire included item generation, item construction, and field testing. To assess the instrument's reliability and validity, we recruited 30 different Korean worksites. We developed the WHI questionnaire of 136 items categorized into five domains, namely Governance and Infrastructure, Need Assessment and Planning, Health Prevention and Promotion Program, Occupational Safety, and Monitoring and Feedback. All WHI domains demonstrated a high reliability with good internal consistency. The total WHI scores differentiated worksite groups effectively according to firm size. Each domain was associated significantly with employees' health status, absence, and financial outcome. The WHI can assess comprehensive worksite health programs. This tool is publicly available for addressing the growing need for worksite health programs.

  16. Psychometric properties and the predictive validity of the insomnia daytime worry scale: a pilot study.

    PubMed

    Kallestad, Håvard; Hansen, Bjarne; Langsrud, Knut; Hjemdal, Odin; Stiles, Tore C

    2010-01-01

    The relationship between presleep worry and insomnia has been investigated in previous studies, but less attention has been given to the role of daytime worry and symptoms of insomnia. The aims of the current study were (a) to assess the psychometric properties of a novel scale measuring insomnia-specific worry during daytime and (b) to examine whether levels of daytime worry predict severity of insomnia symptoms. Participants (N = 353) completed the Insomnia Daytime Worry Scale (IDWS) and the Insomnia Severity Index. An explorative principal-axis factor analysis extracted two factors from the IDWS, accounting for 70.5% of the variance. The IDWS demonstrated good reliability. The total score of IDWS and both factors predicted levels of insomnia severity in two separate hierarchical regression analyses. This preliminary evidence suggests that the IDWS is a valid and reliable scale to measure daytime worry in insomnia.

  17. Psychometric Evaluation of the Patient Health Questionnaire–4 in Hispanic Americans

    PubMed Central

    Mills, Sarah D.; Fox, Rina S.; Pan, Tonya M.; Malcarne, Vanessa L.; Roesch, Scott C.; Sadler, Georgia Robins

    2017-01-01

    The present study evaluated the psychometric properties of the Patient Health Questionnaire-4 (PHQ-4), a screener of psychological distress, in English- and Spanish-speaking Hispanic Americans. Hispanic American adults (N = 436) completed the PHQ-4, which yields two subscales (anxiety and depression) that can be summed to create a total score. Multiple-group confirmatory factor analysis was used to evaluate structural validity. The two-factor structure was the best fit to the data for both English- and Spanish-speaking Hispanic Americans and items loaded equivalently across groups, demonstrating measurement invariance. Internal consistency reliability was good as measured by coefficient alpha. Construct validity was evidenced by significant expected relationships with perceived stress. These findings provide support for the reliability and validity of the PHQ-4 as a brief measure of psychological distress for English- or Spanish-speaking Hispanic Americans. PMID:29097834

  18. Electrical reliability, multilevel data storage and mechanical stability of MoS2-PMMA nanocomposite-based non-volatile memory device

    NASA Astrophysics Data System (ADS)

    Bhattacharjee, Snigdha; Sarkar, Pranab Kumar; Prajapat, Manoj; Roy, Asim

    2017-07-01

    Molybdenum disulfide (MoS2) is of great interest for its applicability in various optoelectronic devices. Here we report the resistive switching properties of polymethylmethacrylate embedding MoS2 nano-crystals. The devices are developed on an ITO-coated PET substrate with copper as the top electrode. Systematic evaluation of resistive switching parameters, on the basis of MoS2 content, suggests non-volatile memory characteristics. A decent ON/OFF ratio, high retention time and long endurance of 3  ×  103, 105 s and 105 cycles are respectively recorded in a device with 1 weight percent (wt%) of MoS2. The bending cyclic measurements confirm the flexibility of the memory devices with good electrical reliability as well as mechanical stability. In addition, multilevel storage has been demonstrated by controlling the current compliance and span of voltage sweeping in the memory device.

  19. Reliability and validity of aggressive driving measures in China.

    PubMed

    Li, Fengzhi; Li, Changji; Long, Yunfang; Zhan, Chenglie; Hennessy, Dwight

    2004-12-01

    The present research was designed to examine the psychometric properties of Chinese versions of the Self Report Driver Behavior Aggression and Assertiveness subscales, the Driving Vengeance Questionnaire, and the Violent Driving Questionnaire. Study 1 found that the all scales demonstrated good internal consistency, with alphas ranging from .76 to .87 and that assertive driving was related to demerit points received over the past 12 months while driver aggression and violence were linked to collisions over the past 12 months. Study 2 found that the scales exhibited reasonable test-retest reliability, with correlations ranging from .82 to .89. Finally, Study 3 showed that each scale was predicted by other dangerous driving attitudes and behaviors, similar to the original versions. The consistency between the translated and original scales, the implications for use in a Chinese sample, and the uniformity of actions in the traffic environment across cultures are discussed.

  20. Psychometric Properties of the Children's Automatic Thoughts Scale (CATS) in Chinese Adolescents.

    PubMed

    Sun, Ling; Rapee, Ronald M; Tao, Xuan; Yan, Yulei; Wang, Shanshan; Xu, Wei; Wang, Jianping

    2015-08-01

    The Children's Automatic Thoughts Scale (CATS) is a 40-item self-report questionnaire designed to measure children's negative thoughts. This study examined the psychometric properties of the Chinese translation of the CATS. Participants included 1,993 students (average age = 14.73) from three schools in Mainland China. A subsample of the participants was retested after 4 weeks. Confirmatory factor analysis replicated the original structure with four first-order factors loading on a single higher-order factor. The convergent and divergent validity of the CATS were good. The CATS demonstrated high internal consistency and test-retest reliability. Boys scored higher on the CATS-hostility subscale, but there were no other gender differences. Older adolescents (15-18 years) reported higher scores than younger adolescents (12-14 years) on the total score and on the physical threat, social threat, and hostility subscales. The CATS proved to be a reliable and valid measure of automatic thoughts in Chinese adolescents.

  1. Underwater Shockwave Pretreatment Process to Improve the Scent of Extracted Citrus junos Tanaka (Yuzu) Juice

    PubMed Central

    Touyama, Akiko; Nakada, Shina; Higa, Osamu; Itoh, Shigeru

    2017-01-01

    Citrus junos Tanaka (yuzu) has a strong characteristic aroma and thus its juice is used in various Japanese foods. Herein, we evaluate the volatile compounds in yuzu juice to investigate whether underwater shockwave pretreatment affects its scent. A shockwave pretreatment at increased discharge and energy of 3.5 kV and 4.9 kJ, respectively, increased the content of aroma-active compounds. Moreover, the underwater shockwave pretreatment afforded an approximate tenfold increase in the scent intensity of yuzu juice cultivated in Rikuzentakata. The proposed treatment method exhibited reliable and good performance for the extraction of volatile and aroma-active compounds from the yuzu fruit. The broad applicability and high reliability of this technique for improving the scent of yuzu fruit juice were demonstrated, confirming its potential for application to a wide range of food extraction processes. PMID:28761874

  2. Choosing a reliability inspection plan for interval censored data

    DOE PAGES

    Lu, Lu; Anderson-Cook, Christine Michaela

    2017-04-19

    Reliability test plans are important for producing precise and accurate assessment of reliability characteristics. This paper explores different strategies for choosing between possible inspection plans for interval censored data given a fixed testing timeframe and budget. A new general cost structure is proposed for guiding precise quantification of total cost in inspection test plan. Multiple summaries of reliability are considered and compared as the criteria for choosing the best plans using an easily adapted method. Different cost structures and representative true underlying reliability curves demonstrate how to assess different strategies given the logistical constraints and nature of the problem. Resultsmore » show several general patterns exist across a wide variety of scenarios. Given the fixed total cost, plans that inspect more units with less frequency based on equally spaced time points are favored due to the ease of implementation and consistent good performance across a large number of case study scenarios. Plans with inspection times chosen based on equally spaced probabilities offer improved reliability estimates for the shape of the distribution, mean lifetime, and failure time for a small fraction of population only for applications with high infant mortality rates. The paper uses a Monte Carlo simulation based approach in addition to the common evaluation based on the asymptotic variance and offers comparison and recommendation for different applications with different objectives. Additionally, the paper outlines a variety of different reliability metrics to use as criteria for optimization, presents a general method for evaluating different alternatives, as well as provides case study results for different common scenarios.« less

  3. Choosing a reliability inspection plan for interval censored data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Lu; Anderson-Cook, Christine Michaela

    Reliability test plans are important for producing precise and accurate assessment of reliability characteristics. This paper explores different strategies for choosing between possible inspection plans for interval censored data given a fixed testing timeframe and budget. A new general cost structure is proposed for guiding precise quantification of total cost in inspection test plan. Multiple summaries of reliability are considered and compared as the criteria for choosing the best plans using an easily adapted method. Different cost structures and representative true underlying reliability curves demonstrate how to assess different strategies given the logistical constraints and nature of the problem. Resultsmore » show several general patterns exist across a wide variety of scenarios. Given the fixed total cost, plans that inspect more units with less frequency based on equally spaced time points are favored due to the ease of implementation and consistent good performance across a large number of case study scenarios. Plans with inspection times chosen based on equally spaced probabilities offer improved reliability estimates for the shape of the distribution, mean lifetime, and failure time for a small fraction of population only for applications with high infant mortality rates. The paper uses a Monte Carlo simulation based approach in addition to the common evaluation based on the asymptotic variance and offers comparison and recommendation for different applications with different objectives. Additionally, the paper outlines a variety of different reliability metrics to use as criteria for optimization, presents a general method for evaluating different alternatives, as well as provides case study results for different common scenarios.« less

  4. Factor structure and reliability of the depression, anxiety and stress scales in a large Portuguese community sample.

    PubMed

    Vasconcelos-Raposo, José; Fernandes, Helder Miguel; Teixeira, Carla M

    2013-01-01

    The purpose of the present study was to assess the factor structure and reliability of the Depression, Anxiety and Stress Scales (DASS-21) in a large Portuguese community sample. Participants were 1020 adults (585 women and 435 men), with a mean age of 36.74 (SD = 11.90) years. All scales revealed good reliability, with Cronbach's alpha values between .80 (anxiety) and .84 (depression). The internal consistency of the total score was .92. Confirmatory factor analysis revealed that the best-fitting model (*CFI = .940, *RMSEA = .038) consisted of a latent component of general psychological distress (or negative affectivity) plus orthogonal depression, anxiety and stress factors. The Portuguese version of the DASS-21 showed good psychometric properties (factorial validity and reliability) and thus can be used as a reliable and valid instrument for measuring depression, anxiety and stress symptoms.

  5. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys

    PubMed Central

    2010-01-01

    Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990

  6. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    PubMed

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  7. Real-time assessment of perioperative behaviors in children and parents: development and validation of the perioperative adult child behavioral interaction scale.

    PubMed

    Sadhasivam, Senthilkumar; Cohen, Lindsey L; Hosu, Liana; Gorman, Kristin L; Wang, Yu; Nick, Todd G; Jou, Jing Fang; Samol, Nancy; Szabova, Alexandra; Hagerman, Nancy; Hein, Elizabeth; Boat, Anne; Varughese, Anna; Kurth, Charles Dean; Willging, J Paul; Gunter, Joel B

    2010-04-01

    Behavior in response to distressful events during outpatient pediatric surgery can contribute to postoperative maladaptive behaviors, such as temper tantrums, nightmares, bed-wetting, and attention seeking. Currently available perioperative behavioral assessment tools have limited utility in guiding interventions to ameliorate maladaptive behaviors because they cannot be used in real time, are only intended to be used during 1 phase of the experience (e.g., perioperative), or provide only a static assessment of the child (e.g., level of anxiety). A simple, reliable, real-time tool is needed to appropriately identify children and parents whose behaviors in response to distressful events at any point in the perioperative continuum could benefit from timely behavioral intervention. Our specific aims were to (1) refine the Perioperative Adult Child Behavioral Interaction Scale (PACBIS) to improve its reliability in identifying perioperative behaviors and (2) validate the refined PACBIS against several established instruments. The PACBIS was used to assess the perioperative behaviors of 89 children aged 3 to 12 years presenting for adenotonsillectomy and their parents. Assessments using the PACBIS were made during perioperative events likely to prove distressing to children and/or parents (perioperative measurement of blood pressure, induction of anesthesia, and removal of the IV catheter before discharge). Static measurements of perioperative anxiety and behavioral compliance during anesthetic induction were made using the modified Yale Preoperative Anxiety Scale and the Induction Compliance Checklist (ICC). Each event was videotaped for later scoring using the Child-Adult Medical Procedure Interaction Scale-Short Form (CAMPIS-SF) and Observational Scale of Behavioral Distress (OSBD). Interrater reliability using linear weighted kappa (kappa(w)) and multiple validations using Spearman correlation coefficients were analyzed. The PACBIS demonstrated good to excellent interrater reliability, with kappa(w) ranging from 0.62 to 0.94. The Child Coping and Child Distress subscores of the PACBIS demonstrated strong concurrent correlations with the modified Yale Preoperative Anxiety Scale, ICC, CAMPIS-SF, and OSBD. The Parent Positive subscore of the PACBIS correlated strongly with the CAMPIS-SF and OSBD, whereas the Parent Negative subscore showed significant correlation with the ICC. The PACBIS has strong construct and predictive validities. The PACBIS is a simple, easy to use, real-time instrument to evaluate perioperative behaviors of both children and parents. It has good to excellent interrater reliability and strong concurrent validity against currently accepted scales. The PACBIS offers a means to identify maladaptive child or parental behaviors in real time, making it possible to intervene to modify such behaviors in a timely fashion.

  8. Can we have an overall osteoarthritis severity score for the patellofemoral joint using magnetic resonance imaging? Reliability and validity.

    PubMed

    Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos

    2018-04-01

    This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.

  9. Psychometric properties of seven self-report measures of posttraumatic stress disorder in college students with mixed civilian trauma exposure.

    PubMed

    Adkins, Jennifer W; Weathers, Frank W; McDevitt-Murphy, Meghan; Daniels, Jennifer B

    2008-12-01

    In this study psychometric properties of seven self-report measures of posttraumatic stress disorder (PTSD) were compared. The seven scales evaluated were the Davidson Trauma Scale (DTS), the PTSD Checklist (PCL), the Posttraumatic Stress Diagnostic Scale (PDS), the Civilian Mississippi Scale (CMS), the Impact of Event Scale-Revised (IES-R), the Penn Inventory for Posttraumatic Stress Disorder (Penn), and the PK scale of the MMPI-2 (PK). Participants were 239 (79 male and 160 female) trauma-exposed undergraduates. All seven measures exhibited good test-retest reliability and internal consistency. The PDS, PCL and DTS demonstrated the best convergent validity; the IES-R, PDS, and PCL demonstrated the best discriminant validity; and the PDS, PCL, and IES-R demonstrated the best diagnostic utility. Overall, results most strongly support the use of the PDS and the PCL for the assessment of PTSD in this population.

  10. Validity of the Family Asthma Management System Scale with an urban African-American sample.

    PubMed

    Celano, Marianne; Klinnert, Mary D; Holsey, Chanda Nicole; McQuaid, Elizabeth L

    2011-06-01

    To examine the reliability and validity of the Family Asthma Management System Scale for low-income African-American children with poor asthma control and caregivers under stress. The FAMSS assesses eight aspects of asthma management from a family systems perspective. Forty-three children, ages 8-13, and caregivers were interviewed with the FAMSS; caregivers completed measures of primary care quality, family functioning, parenting stress, and psychological distress. Children rated their relatedness with the caregiver, and demonstrated inhaler technique. Medical records were reviewed for dates of outpatient visits for asthma. The FAMSS demonstrated good internal consistency. Higher scores were associated with adequate inhaler technique, recent outpatient care, less parenting stress and better family functioning. Higher scores on the Collaborative Relationship with Provider subscale were associated with greater perceived primary care quality. The FAMSS demonstrated relevant associations with asthma management criteria and family functioning for a low-income, African-American sample.

  11. Validity and reliability of the Brazilian version of Yale-Brown obsessive compulsive scale-shopping version (YBOCS-SV).

    PubMed

    Leite, Priscilla Lourenço; Filomensky, Tatiana Zambrano; Black, Donald W; Silva, Adriana Cardoso

    2014-08-01

    The Yale-Brown Obsessive Compulsive Scale-Shopping Version (YBOCS-SV) is considered the gold standard in the assessment of shopping severity. It is designed to assess cognitions and behaviors relating to compulsive buying behavior. The present study aims to assess the validity of the Brazilian version of this scale. For the study, composed the sample 610 participants: 588 subjects of a general population and 22 compulsive buyers. Factorial analysis was performed to assess the relations and the correlation between the YBOCS-SV, the Compulsive Buying Scale (CBS), and Richmond Compulsive Buying Scale (RCBS), was assessed using Pearson coefficient, for study of convergent and divergent validity. Cronbach's alpha coefficients were used to assess internal consistency. The results show good to excellent psychometric parameters for the YBOCS-SV in its Brazilian version. With regard to correlations, the YBOCS-SV is inversely and proportionally correlated with CBS and the RCBS, indicating that the YBOCS-SV is an excellent instrument for screening compulsive buying. The YBOCS-SV presented high alpha coefficient of Cronbach's alpha (0.92), demonstrating good reliability. The Brazilian version of the YBOCS-SV is indicated to diagnose compulsive buying disorder, and likely use for the purposes intended in the Brazilian population. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. How to measure the impact of premenstrual symptoms? Development and validation of the German PMS-Impact Questionnaire.

    PubMed

    Kues, Johanna N; Janda, Carolyn; Kleinstäuber, Maria; Weise, Cornelia

    2016-10-01

    With 75% of women of reproductive age affected, premenstrual symptoms are very common, ranging from emotional and cognitive to physical symptoms. Premenstrual Syndrome and Premenstrual Dysphoric Disorder can lead to substantial functional interference and psychological distress comparable to that of dysthymic disorders. The assessment of this impact is required as a part of the diagnostic procedure in the DSM-5. In the absence of a specific measure, the authors developed the PMS-Impact Questionnaire. A sample of 101 women reporting severe premenstrual complaints was assessed with the twenty-two items in the questionnaire during their premenstrual phase in an ongoing intervention study at the Philipps-University Marburg from August 2013 until January 2015. An exploratory factor analysis revealed a two-factor solution (labeled Psychological Impact and Functional Impact) with 18 items. A Cronbach's alpha of 0.90 for Psychological Impact and of 0.90 for Functional Impact indicated good reliability. Convergent construct validity was demonstrated by moderate to high correlations with the Pain Disability Index. Low correlations with the Big Five Inventory-10 indicated good divergent validity. The PMS-Impact Questionnaire was found to be a valid, reliable, and an economic measure to assess the impact of premenstrual symptoms. In future research, cross validations and confirmatory factor analyses should be conducted.

  13. Preliminary validation of the Yale Food Addiction Scale.

    PubMed

    Gearhardt, Ashley N; Corbin, William R; Brownell, Kelly D

    2009-04-01

    Previous research has found similarities between addiction to psychoactive substances and excessive food consumption. Further exploration is needed to evaluate the concept of "food addiction," as there is currently a lack of psychometrically validated measurement tools in this area. The current study represents a preliminary exploration of the Yale Food Addiction Scale (YFAS), designed to identify those exhibiting signs of addiction towards certain types of foods (e.g., high fat and high sugar). Survey data were collected from 353 respondents from a stratified random sample of young adults. In addition to the YFAS, the survey assessed eating pathology, alcohol consumption and other health behaviors. The YFAS exhibited adequate internal reliability, and showed good convergent validity with measures of similar constructs and good discriminant validity relative to related but dissimilar constructs. Additionally, the YFAS predicted binge-eating behavior above and beyond existing measures of eating pathology, demonstrating incremental validity. The YFAS is a sound tool for identifying eating patterns that are similar to behaviors seen in classic areas of addiction. Further evaluation of the scale is needed, especially due to a low response rate of 24.5% and a non-clinical sample, but confirmation of the reliability and validity of the scale has the potential to facilitate empirical research on the concept of "food addiction".

  14. Development of the family symptom inventory: a psychosocial screener for children with hematology/oncology conditions.

    PubMed

    Karlson, Cynthia W; Haynes, Stacey; Faith, Melissa A; Elkin, Thomas D; Smith, Maria L; Megason, Gail

    2015-03-01

    A growing body of literature has begun to underscore the importance of integrating family-based comprehensive psychological screening into standard medical care for children with oncology and hematology conditions. There are no known family-based measures designed to screen for clinically significant emotional and behavioral concerns in pediatric oncology and hematology patients. The aim of this study was to develop and evaluate the Family Symptom Inventory (FSI), a brief screener of patient and family member psychological symptoms. The FSI also screens for common comorbid physical symptoms (pain and sleep disturbance) and is designed for use at any point during treatment and follow-up. A total of 488 caregivers completed the FSI during regular hematology/oncology visits for 193 cancer, 219 sickle cell disease, and 76 hematology pediatric patients. Exploratory factor analysis, confirmatory factor analysis, and tests of reliability and preliminary validity were conducted. Exploratory factor analysis suggested a 34-item, 4-factor solution, which was confirmed in an independent sample using confirmatory factor analysis (factor loadings=0.49 to 0.88). The FSI demonstrated good internal reliability (α's=0.86 to 0.92) and good preliminary validity. Regular psychosocial screening throughout the course of treatment and follow-up may lead to improved quality of care for children with oncology and hematology conditions.

  15. Rasch analysis and impact factor methods both yield valid and comparable measures of health status in interstitial lung disease.

    PubMed

    Patel, Amit S; Siegert, Richard J; Bajwah, Sabrina; Brignall, Kate; Gosker, Harry R; Moxham, John; Maher, Toby M; Renzoni, Elisabetta A; Wells, Athol U; Higginson, Irene J; Birring, Surinder S

    2015-09-01

    Rasch analysis has largely replaced impact factor methodology for developing health status measures. The aim of this study was to develop a health status questionnaire for patients with interstitial lung disease (ILD) using impact factor methodology and to compare its validity with that of another version developed using Rasch analysis. A preliminary 71-item questionnaire was developed and evaluated in 173 patients with ILD. Items were reduced by the impact factor method (King's Brief ILD questionnaire, KBILD-I) and Rasch analysis (KBILD-R). Both questionnaires were validated by assessing their relationship with forced vital capacity (FVC) and St Georges Respiratory Questionnaire (SGRQ) and by evaluating internal reliability, repeatability, and longitudinal responsiveness. The KBILD-R and KBILD-I comprised 15 items each. The content of eight items differed between the KBILD-R and KBILD-I. Internal and test-retest reliability was good for total scores of both questionnaires. There was a good relationship with SGRQ and moderate relationship with FVC for both questionnaires. Effect sizes were comparable. Both questionnaires discriminated patients with differing disease severity. Despite considerable differences in the content of retained items, both KBILD-R and KBILD-I questionnaires demonstrated acceptable measurement properties and performed comparably in a clinical setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Development of ultracapacitor modules for 42-V automotive electrical systems

    NASA Astrophysics Data System (ADS)

    Jung, Do Yang; Kim, Young Ho; Kim, Sun Wook; Lee, Suck-Hyun

    Two types of ultracapacitor modules have been developed for use as energy-storage devices for 42-V systems in automobiles. The modules show high performance and good reliability in terms of discharge and recharge capability, long-term endurance, and high energy and power. During a 42-V system simulation test of 6-kW power boosting/regenerative braking, the modules demonstrate very good performance. In high-power applications such as 42-V and hybrid vehicle systems, ultracapacitors have many merits compared with batteries, especially with respect to specific power at high rate, thermal stability, charge-discharge efficiency, and cycle-life. Ultracapacitors are also very safe, reliable and environmentally friendly. The cost of ultracapacitors is still high compared with batteries because of the low production scale, but is decreasing very rapidly. It is estimated that the cost of ultracapacitors will decrease to US$ 300 per 42-V module in the near future. Also, the maintenance cost of the ultracapacitor is nearly zero because of its high cycle-life. Therefore, the combined cost of the capacitor and maintenance will be lower than that of batteries in the near future. Overall, comparing performance, price and other parameters of ultracapacitors with batteries, ultracapacitors are the most likely candidate for energy-storage in 42-V systems.

  17. Thermal Performance Study of Composite Phase Change Material with Polyacrylicand Conformal Coating.

    PubMed

    Kee, Shin Yiing; Munusamy, Yamuna; Ong, Kok Seng; Cornelis Metselaar, Hendrik Simon; Chee, Swee Yong; Lai, Koon Chun

    2017-07-28

    The composite PCM was prepared by blending polymethyl methacrylate (PMMA) and myristic acid (MA) in different weight percentages. The MA and PMMA were selected as PCM and supporting material, respectively. As liquid MA may leak out during the phase transition, this study proposes the use of two coatings, namely a polyacrylic coating and a conformal coating to overcome the leakage problem. Both coatings were studied in terms of the leakage test, chemical compatibility, thermal stability, morphology, and reliability. No leakage was found in the PCMs with coatings compared to those without under the same proportions of MA/PMMA, thus justifying the use of coatings in the present study. The chemically compatibility was confirmed by FTIR spectra: the functional groups of PCMs were in accordance with those of coatings. DSC showed that the coatings did not significantly change the melting and freezing temperatures, however, they improved the thermal stability of composite PCMs as seen in TGA analysis. Furthermore, the composite PCMs demonstrated good thermal reliability after 1000 times thermal cycling. The latent heat of melting reduced by only 0.16% and 1.02% for the PCMs coated with conformal coating and polyacrylic coating, respectively. Therefore, the proposed coatings can be considered in preparing fatty acid/PMMA blends attributed to the good stability, compatibility and leakage prevention.

  18. Validity of Exercise Measures in Adults with Anorexia Nervosa: The EDE, Compulsive Exercise Test and Other Self-Report Scales.

    PubMed

    Young, Sarah; Touyz, Stephen; Meyer, Caroline; Arcelus, Jon; Rhodes, Paul; Madden, Sloane; Pike, Kathleen; Attia, Evelyn; Crosby, Ross D; Wales, Jackie; Hay, Phillipa

    2017-05-01

    Compulsive exercise is a prominent feature for the majority of patients with Anorexia Nervosa (AN), but there is a dearth of research evaluating assessment instruments. This study assessed the concurrent validity of the exercise items of the Eating Disorder Examination (EDE) and Eating Disorder Examination-Questionnaire (EDE-Q), with the Compulsive Exercise Test (CET) and other self-report exercise measures in patients with AN. We also aimed to perform validation of the CET in an adult clinical sample. The sample consisted of 78 adults with AN, recruited for the randomized controlled trial "Taking a LEAP forward in the treatment of anorexia nervosa." At baseline, participants completed the EDE, EDE-Q, CET, Reasons for Exercise Inventory (REI), Commitment to Exercise Scale (CES) and Exercise Beliefs Questionnaire (EBQ). Correlational and regression analyses were performed. EDE exercise days and exercise time per day were positively correlated with each other and with all CET subscales (except Lack of exercise enjoyment), CES mean, EBQ total and REI total. Exercise time per day was associated with a higher EDE global score. The CET demonstrated good concurrent validity with the CES, the REI and the EBQ. Of the self-reports, the CET explained the greatest variance in eating disorder psychopathology and demonstrated good to excellent reliability in this sample. The EDE and EDE-Q demonstrated good concurrent validity with the CET. Further research is required to evaluate the CET's factor structure in a large clinical sample. However, the CET has demonstrated strong clinical utility in adult patients with AN. © 2016 Wiley Periodicals, Inc.(Int J Eat Disord 2017; 50:533-541). © 2016 Wiley Periodicals, Inc.

  19. Stability of steady hand force production explored across spaces and methods of analysis.

    PubMed

    de Freitas, Paulo B; Freitas, Sandra M S F; Lewis, Mechelle M; Huang, Xuemei; Latash, Mark L

    2018-06-01

    We used the framework of the uncontrolled manifold (UCM) hypothesis and explored the reliability of several outcome variables across different spaces of analysis during a very simple four-finger accurate force production task. Fourteen healthy, young adults performed the accurate force production task with each hand on 3 days. Small spatial finger perturbations were generated by the "inverse piano" device three times per trial (lifting the fingers 1 cm/0.5 s and lowering them). The data were analyzed using the following main methods: (1) computation of indices of the structure of inter-trial variance and motor equivalence in the space of finger forces and finger modes, and (2) analysis of referent coordinates and apparent stiffness values for the hand. Maximal voluntary force and the index of enslaving (unintentional finger force production) showed good to excellent reliability. Strong synergies stabilizing total force were reflected in both structure of variance and motor equivalence indices. Variance within the UCM and the index of motor equivalent motion dropped over the trial duration and showed good to excellent reliability. Variance orthogonal to the UCM and the index of non-motor equivalent motion dropped over the 3 days and showed poor to moderate reliability. Referent coordinate and apparent stiffness indices co-varied strongly and both showed good reliability. In contrast, the computed index of force stabilization showed poor reliability. The findings are interpreted within the scheme of neural control with referent coordinates involving the hierarchy of two basic commands, the r-command and c-command. The data suggest natural drifts in the finger force space, particularly within the UCM. We interpret these drifts as reflections of a trade-off between stability and optimization of action. The implications of these findings for the UCM framework and future clinical applications are explored in the discussion. Indices of the structure of variance and motor equivalence show good reliability and can be recommended for applied studies.

  20. Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball.

    PubMed

    Luteberget, Live S; Holme, Benjamin R; Spencer, Matt

    2018-04-01

    To assess the reliability and sensitivity of commercially available inertial measurement units to measure physical activity in team handball. Twenty-two handball players were instrumented with 2 inertial measurement units (OptimEye S5; Catapult Sports, Melbourne, Australia) taped together. They participated in either a laboratory assessment (n = 10) consisting of 7 team handball-specific tasks or field assessment (n = 12) conducted in 12 training sessions. Variables, including PlayerLoad™ and inertial movement analysis (IMA) magnitude and counts, were extracted from the manufacturers' software. IMA counts were divided into intensity bands of low (1.5-2.5 m·s -1 ), medium (2.5-3.5 m·s -1 ), high (>3.5 m·s -1 ), medium/high (>2.5 m·s -1 ), and total (>1.5 m·s -1 ). Reliability between devices and sensitivity was established using coefficient of variation (CV) and smallest worthwhile difference (SWD). Laboratory assessment: IMA magnitude showed a good reliability (CV = 3.1%) in well-controlled tasks. CV increased (4.4-6.7%) in more-complex tasks. Field assessment: Total IMA counts (CV = 1.8% and SWD = 2.5%), PlayerLoad (CV = 0.9% and SWD = 2.1%), and their associated variables (CV = 0.4-1.7%) showed a good reliability, well below the SWD. However, the CV of IMA increased when categorized into intensity bands (2.9-5.6%). The reliability of IMA counts was good when data were displayed as total, high, or medium/high counts. A good reliability for PlayerLoad and associated variables was evident. The CV of the previously mentioned variables was well below the SWD, suggesting that OptimEye's inertial measurement unit and its software are sensitive for use in team handball.

  1. Test-retest reliability of the Middlesex Assessment of Mental State (MEAMS): a preliminary investigation in people with probable dementia.

    PubMed

    Powell, T; Brooker, D J; Papadopolous, A

    1993-05-01

    Relative and absolute test-retest reliability of the MEAMS was examined in 12 subjects with probable dementia and 12 matched controls. Relative reliability was good. Measures of absolute reliability showed scores changing by up to 3 points over an interval of a week. A version effect was found to be in evidence.

  2. Predictive validity of a selection centre testing non-technical skills for recruitment to training in anaesthesia.

    PubMed

    Gale, T C E; Roberts, M J; Sice, P J; Langton, J A; Patterson, F C; Carr, A S; Anderson, I R; Lam, W H; Davies, P R F

    2010-11-01

    Assessment centres are an accepted method of recruitment in industry and are gaining popularity within medicine. We describe the development and validation of a selection centre for recruitment to speciality training in anaesthesia based on an assessment centre model incorporating the rating of candidate's non-technical skills. Expert consensus identified non-technical skills suitable for assessment at the point of selection. Four stations-structured interview, portfolio review, presentation, and simulation-were developed, the latter two being realistic scenarios of work-related tasks. Evaluation of the selection centre focused on applicant and assessor feedback ratings, inter-rater agreement, and internal consistency reliability coefficients. Predictive validity was sought via correlations of selection centre scores with subsequent workplace-based ratings of appointed trainees. Two hundred and twenty-four candidates were assessed over two consecutive annual recruitment rounds; 68 were appointed and followed up during training. Candidates and assessors demonstrated strong approval of the selection centre with more than 70% of ratings 'good' or 'excellent'. Mean inter-rater agreement coefficients ranged from 0.62 to 0.77 and internal consistency reliability of the selection centre score was high (Cronbach's α=0.88-0.91). The overall selection centre score was a good predictor of workplace performance during the first year of appointment. An assessment centre model based on the rating of non-technical skills can produce a reliable and valid selection tool for recruitment to speciality training in anaesthesia. Early results on predictive validity are encouraging and justify further development and evaluation.

  3. from the Adolescents’ Perspective in Malaysia

    PubMed

    Mohd Zin, Faridah; Hillaluddin, Azlin Hilma; Mustaffa, Jamaludin

    2017-05-01

    Objective: This study aims to develop, validate and determine the reliability of an interactive multimedia strategy to prevent tobacco use among the young (TUPY-S) from an adolescents’ perspective. Methods: A descriptive study design was utilized. A modular instruction guideline by Russel (1974) was followed in the entire process, comprising a feasibility study, a review of existing modules, specification of the objectives, identification of the construct criterion items, learner analysis and entry behavior specification, establishment of the sequence instruction and media selection, a tryout with students and a field test. Result: Feasibility was agreed among the researchers and the school authorities. Culturally suitable rigorously developed tobacco use preventive strategies delivered using information technology (IT) are lacking in the literature. The objective of TUPY-S is to prevent tobacco use among adolescents living in Malaysia. Identified construct criterion items include knowledge, attitude, intention to use, self-efficacy, and refusal skill. The target population was early adolescents belonging to generation-Z. Content was developed from the adolescents’ perspective and delivered using IT in Malay language. Content validity, assessed by six experts in the field and module development, was good at 86%. The students’ tryout showed satisfactory face validity subjectively and objectively (85.5%) and high alpha Cronbach reliability (0.91). Conclusion: TUPY-S was confirmed to suit early adolescents of the current generation living in Malaysia. It demonstrated good content validity among the experts, satisfactory face validity and reliability among the target population. TUPY-S is ready to be evaluated for its effectiveness among early adolescents. Creative Commons Attribution License

  4. Objective structured assessment of nontechnical skills: Reliability of a global rating scale for the in-training assessment in the operating room.

    PubMed

    Dedy, Nicolas J; Szasz, Peter; Louridas, Marisa; Bonrath, Esther M; Husslein, Heinrich; Grantcharov, Teodor P

    2015-06-01

    Nontechnical skills are critical for patient safety in the operating room (OR). As a result, regulatory bodies for accreditation and certification have mandated the integration of these competencies into postgraduate education. A generally accepted approach to the in-training assessment of nontechnical skills, however, is lacking. The goal of the present study was to develop an evidence-based and reliable tool for the in-training assessment of residents' nontechnical performance in the OR. The Objective Structured Assessment of Nontechnical Skills tool was designed as a 5-point global rating scale with descriptive anchors for each item, based on existing evidence-based frameworks of nontechnical skills, as well as resident training requirements. The tool was piloted on scripted videos and refined in an iterative process. The final version was used to rate residents' performance in recorded OR crisis simulations and during live observations in the OR. A total of 37 simulations and 10 live procedures were rated. Interrater agreement was good for total mean scores, both in simulation and in the real OR, with intraclass correlation coefficients >0.90 in all settings for average and single measures. Internal consistency of the scale was high (Cronbach's alpha = 0.80). The Objective Structured Assessment of Nontechnical Skills global rating scale was developed as an evidence-based tool for the in-training assessment of residents' nontechnical performance in the OR. Unique descriptive anchors allow for a criterion-referenced assessment of performance. Good reliability was demonstrated in different settings, supporting applications in research and education. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Etiologic Ischemic Stroke Phenotypes in the NINDS Stroke Genetics Network

    PubMed Central

    Ay, Hakan; Arsava, Ethem Murat; Andsberg, Gunnar; Benner, Thomas; Brown, Robert D.; Chapman, Sherita N.; Cole, John W.; Delavaran, Hossein; Dichgans, Martin; Engström, Gunnar; Giralt-Steinhauer, Eva; Grewal, Raji P.; Gwinn, Katrina; Jern, Christina; Jimenez-Conde, Jordi; Jood, Katarina; Katsnelson, Michael; Kissela, Brett; Kittner, Steven J.; Kleindorfer, Dawn O.; Labovitz, Daniel L.; Lanfranconi, Silvia; Lee, Jin-Moo; Lehm, Manuel; Lemmens, Robin; Levi, Chris; Li, Linxin; Lindgren, Arne; Markus, Hugh S.; McArdle, Patrick F.; Melander, Olle; Norrving, Bo; Peddareddygari, Leema Reddy; Pedersén, Annie; Pera, Joanna; Rannikmäe, Kristiina; Rexrode, Kathryn M.; Rhodes, David; Rich, Stephen S.; Roquer, Jaume; Rosand, Jonathan; Rothwell, Peter M.; Rundek, Tatjana; Sacco, Ralph L.; Schmidt, Reinhold; Schürks, Markus; Seiler, Stephan; Sharma, Pankaj; Slowik, Agnieszka; Sudlow, Cathie; Thijs, Vincent; Woodfield, Rebecca; Worrall, Bradford B.; Meschia, James F.

    2014-01-01

    Background and Purpose NINDS Stroke Genetics Network (SiGN) is an international consortium of ischemic stroke studies that aims to generate high quality phenotype data to identify the genetic basis of etiologic stroke subtypes. This analysis characterizes the etiopathogenetic basis of ischemic stroke and reliability of stroke classification in the consortium. Methods Fifty-two trained and certified adjudicators determined both phenotypic (abnormal test findings categorized in major etiologic groups without weighting towards the most likely cause) and causative ischemic stroke subtypes in 16,954 subjects with imaging-confirmed ischemic stroke from 12 US studies and 11 studies from 8 European countries using the web-based Causative Classification of Stroke System. Classification reliability was assessed with blinded re-adjudication of 1509 randomly selected cases. Results The distribution of etiologic categories varied by study, age, sex, and race (p<0.001 for each). Overall, only 40% to 54% of cases with a given major ischemic stroke etiology (phenotypic subtype) were classified into the same final causative category with high confidence. There was good agreement for both causative (kappa 0.72, 95%CI:0.69-0.75) and phenotypic classifications (kappa 0.73, 95%CI:0.70-0.75). Conclusions This study demonstrates that etiologic subtypes can be determined with good reliability in studies that include investigators with different expertise and background, institutions with different stroke evaluation protocols and geographic location, and patient populations with different epidemiological characteristics. The discordance between phenotypic and causative stroke subtypes highlights the fact that the presence of an abnormality in a stroke patient does not necessarily mean that it is the cause of stroke. PMID:25378430

  6. Rasch analysis of the Italian Lower Extremity Functional Scale: insights on dimensionality and suggestions for an improved 15-item version.

    PubMed

    Bravini, Elisabetta; Giordano, Andrea; Sartorio, Francesco; Ferriero, Giorgio; Vercelli, Stefano

    2017-04-01

    To investigate dimensionality and the measurement properties of the Italian Lower Extremity Functional Scale using both classical test theory and Rasch analysis methods, and to provide insights for an improved version of the questionnaire. Rasch analysis of individual patient data. Rehabilitation centre. A total of 135 patients with musculoskeletal diseases of the lower limb. Patients were assessed with the Lower Extremity Functional Scale before and after the rehabilitation. Rasch analysis showed some problems related to rating scale category functioning, items fit, and items redundancy. After an iterative process, which resulted in the reduction of rating scale categories from 5 to 4, and in the deletion of 5 items, the psychometric properties of the Italian Lower Extremity Functional Scale improved. The retained 15 items with a 4-level response format fitted the Rasch model (internal construct validity), and demonstrated unidimensionality and good reliability indices (person-separation reliability 0.92; Cronbach's alpha 0.94). Then, the analysis showed differential item functioning for six of the retained items. The sensitivity to change of the Italian 15-item Lower Extremity Functional Scale was nearly equal to the one of the original version (effect size: 0.93 and 0.98; standardized response mean: 1.20 and 1.28, respectively for the 15-item and 20-item versions). The Italian Lower Extremity Functional Scale had unsatisfactory measurement properties. However, removing five items and simplifying the scoring from 5 to 4 levels resulted in a more valid measure with good reliability and sensitivity to change.

  7. Reliability of Radiographic Assessments of Adolescent Midshaft Clavicle Fractures by the FACTS Multicenter Study Group.

    PubMed

    Li, Ying; Donohue, Kyna S; Robbins, Christopher B; Pennock, Andrew T; Ellis, Henry B; Nepple, Jeffrey J; Pandya, Nirav; Spence, David D; Willimon, Samuel Clifton; Heyworth, Benton E

    2017-09-01

    There is a recent trend toward increased surgical treatment of displaced midshaft clavicle fractures in adolescents. The primary purpose of this study was to evaluate the intrarater and interrater reliability of clavicle fracture classification systems and measurements of displacement, shortening, and angulation in adolescents. The secondary purpose was to compare 2 different measurement methods for fracture shortening. This study was performed by a multicenter study group conducting a prospective, comparative, observational cohort study of adolescent clavicle fractures. Eight raters evaluated 24 deidentified anteroposterior clavicle radiographs selected from patients 10-18 years of age with midshaft clavicle fractures. Two clavicle fracture classification systems were used, and 2 measurements for shortening, 1 measurement for superior-inferior displacement, and 2 measurements for fracture angulation were performed. A minimum of 2 weeks after the first round, the process was repeated. Intraclass correlation coefficients were calculated. Good to excellent intrarater and interrater agreement was achieved for the descriptive classification system of fracture displacement, direction of angulation, presence of comminution, and all continuous variables, including both measurements of shortening, superior-inferior displacement, and degrees of angulation. Moderate agreement was achieved for the Arbeitsgemeinschaft für Osteosynthesefragen classification system overall. Mean shortening by 2 different methods were significantly different from each other (P < 0.0001). Most radiographic measurements performed by investigators in a multicenter, prospective cohort study of adolescent clavicle fractures demonstrated good-to-excellent intrarater and interrater reliability. Future consensus on the most accurate and clinically appropriate measurement method for fracture shortening is critical.

  8. The Parent Trauma Response Questionnaire (PTRQ): development and preliminary validation

    PubMed Central

    Creswell, Cathy; Dalgleish, Tim; Fearon, Pasco; Goodall, Ben; McKinnon, Anna; Smith, Patrick; Wright, Isobel

    2018-01-01

    ABSTRACT Background: Following a child’s experience of trauma, parental response is thought to play an important role in either facilitating or hindering their psychological adjustment. However, the ability to investigate the role of parenting responses in the post-trauma period has been hampered by a lack of valid and reliable measures. Objectives: The aim of this study was to design, and provide a preliminary validation of, the Parent Trauma Response Questionnaire (PTRQ), a self-report measure of parental appraisals and support for children’s coping, in the aftermath of child trauma. Methods: We administered an initial set of 78 items to 365 parents whose children, aged 2–19 years, had experienced a traumatic event. We conducted principal axis factoring and then assessed the validity of the reduced measure against a standardized general measure of parental overprotection and via the measure’s association with child post-trauma mental health. Results: Factor analysis generated three factors assessing parental maladaptive appraisals: (i) permanent change/damage, (ii) preoccupation with child’s vulnerability, and (iii) self-blame. In addition, five factors were identified that assess parental support for child coping: (i) behavioural avoidance, (ii) cognitive avoidance, (iii) overprotection, (iv) maintaining pre-trauma routines, and (v) approach coping. Good validity was evidenced against the measure of parental overprotection and child post-traumatic stress symptoms. Good test–retest reliability of the measure was also demonstrated. Conclusions: The PTRQ is a valid and reliable self-report assessment of parenting cognitions and coping in the aftermath of child trauma. PMID:29938010

  9. Effect of reflective p-type ohmic contact on thermal reliability of vertical InGaN/GaN LEDs

    NASA Astrophysics Data System (ADS)

    Son, Jun Ho; Song, Yang Hee; Kim, Buem Joon; Lee, Jong-Lam

    2014-11-01

    We report on the enhanced thermal reliability of vertical-LEDs (VLEDs) using novel reflective p-type ohmic contacts with good thermal stability. The reflective p-type ohmic contacts with Ni/Ag-Cu alloy multi-layer structure shows low contact resistivity, as low as 9.3 × 10-6 Ωcm2, and high reflectance of 86% after annealing at 450°C. The V-LEDs with Ni/Ag-Cu alloy multi-layer structure show good thermal reliability with stress time at 300°C in air ambient. The improved thermal stability of the reflective ohmic contacts to p-type GaN is believed to play a critical role in the thermal reliability of V-LEDs. [Figure not available: see fulltext.

  10. Validity and Reliability of Wii Fit Balance Board for the Assessment of Balance of Healthy Young Adults and the Elderly

    PubMed Central

    Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen

    2013-01-01

    [Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86–0.99) for the elderly people and positive correlations (r = 0.58–0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability. PMID:24259769

  11. Validity and reliability of the Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) in Japanese patients with bipolar disorder.

    PubMed

    Toyoshima, Kuniyoshi; Fujii, Yutaka; Mitsui, Nobuyuki; Kako, Yuki; Asakura, Satoshi; Martinez-Aran, Anabel; Vieta, Eduard; Kusumi, Ichiro

    2017-08-01

    In Japan, there are currently no reliable rating scales for the evaluation of subjective cognitive impairment in patients with bipolar disorder. We studied the relationship between the Japanese version of the Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) and objective cognitive assessments in patients with bipolar disorder. We further assessed the reliability and validity of the COBRA. Forty-one patients, aged 16-64, in a remission period of bipolar disorder were recruited from Hokkaido University Hospital in Sapporo, Japan. The COBRA (Japanese version) and Frankfurt Complaint Questionnaire (FCQ), the gold standard in subjective cognitive assessment, were administered. A battery of neuropsychological tests was employed to measure objective cognitive impairment. Correlations among the COBRA, FCQ, and neuropsychological tests were determined using Spearman's correlation coefficient. The Japanese version of the COBRA had high internal consistency, good retest reliability, and concurrent validity-as indicated by a strong correlation with the FCQ. A significant correlation was also observed between the COBRA and objective cognitive measurements of processing speed. These findings are the first to demonstrate that the Japanese version of the COBRA may be clinically useful as a subjective cognitive impairment rating scale in Japanese patients with bipolar disorder. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  12. Intrarater test-retest reliability of static and dynamic stability indexes measurement using the Biodex Stability System during unilateral stance.

    PubMed

    Arifin, Nooranida; Abu Osman, Noor Azuan; Wan Abas, Wan Abu Bakar

    2014-04-01

    The measurements of postural balance often involve measurement error, which affects the analysis and interpretation of the outcomes. In most of the existing clinical rehabilitation research, the ability to produce reliable measures is a prerequisite for an accurate assessment of an intervention after a period of time. Although clinical balance assessment has been performed in previous study, none has determined the intrarater test-retest reliability of static and dynamic stability indexes during dominant single stance. In this study, one rater examined 20 healthy university students (female=12, male=8) in two sessions separated by 7 day intervals. Three stability indexes--the overall stability index (OSI), anterior/posterior stability index (APSI), and medial/ lateral stability index (MLSI) in static and dynamic conditions--were measured during single dominant stance. Intraclass correlation coefficient (ICC), standard error measurement (SEM) and 95% confidence interval (95% CI) were calculated. Test-retest ICCs for OSI, APSI, and MLSI were 0.85, 0.78, and 0.84 during static condition and were 0.77, 0.77, and 0.65 during dynamic condition, respectively. We concluded that the postural stability assessment using Biodex stability system demonstrates good-to-excellent test-retest reliability over a 1 week time interval.

  13. Validating Neuro-QoL short forms and targeted scales with people who have multiple sclerosis.

    PubMed

    Miller, Deborah M; Bethoux, Francois; Victorson, David; Nowinski, Cindy J; Buono, Sarah; Lai, Jin-Shei; Wortman, Katy; Burns, James L; Moy, Claudia; Cella, David

    2016-05-01

    Multiple sclerosis (MS) is a chronic, progressive, and disabling disease of the central nervous system with dramatic variations in the combination and severity of symptoms it can produce. The lack of reliable disease-specific health-related quality of life (HRQL) measures for use in clinical trials prompted the development of the Neurology Quality of Life (Neuro-QOL) instrument, which includes 13 scales that assess physical, emotional, cognitive, and social domains, for use in a variety of neurological illnesses. The objective of this research paper is to conduct an initial assessment of the reliability and validation of the Neuro-QOL short forms (SFs) in MS. We assessed reliability, concurrent validity, known groups validity, and responsiveness between cross-sectional and longitudinal data in 161 recruited MS patients. Internal consistency was high for all measures (α = 0.81-0.95) and ICCs were within the acceptable range (0.76-0.91); concurrent and known groups validity were highest with the Global HRQL question. Longitudinal assessment was limited by the lack of disease progression in the group. The Neuro-QOL SFs demonstrate good internal consistency, test-re-test reliability, and concurrent and known groups validity in this MS population, supporting the validity of Neuro-QOL in adults with MS. © The Author(s), 2015.

  14. Parent-reported social support for child's fruit and vegetable intake: validity of measures.

    PubMed

    Dave, Jayna M; Evans, Alexandra E; Condrasky, Marge D; Williams, Joel E

    2012-01-01

    To develop and validate measures of parental social support to increase their child's fruit and vegetable (FV) consumption. Cross-sectional study design. School and home. Two hundred three parents with at least 1 elementary school-aged child. Parents completed a questionnaire that included instrumental social support scale (ISSPS), emotional social support scale (ESSPS), household FV availability and accessibility index, and demographics. Exploratory factor analysis with promax rotation was conducted to obtain the psychometric properties of ISSPS and ESSPS. Internal consistency and test-retest reliabilities were also assessed. Factor analysis indicated a 4-factor model for ESSPS: positive encouragement, negative role modeling, discouragement, and an item cluster called reinforcement. Psychometric properties indicated that ISSPS performed best as independent single scales with α = .87. Internal consistency reliabilities were acceptable, and test-retest reliabilities ranged from low to acceptable. Correlations between scales, subscales, and item clusters were significant (P < .05). In addition, ISSPS and the positive encouragement subscale were significantly correlated with household FV availability. The ISSPS and ESSPS subscales demonstrated good internal consistency reliability and are suitable for impact assessment of an intervention designed to target parents to help their children eat more fruit and vegetables. Copyright © 2012 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  15. Developing and testing the patient-centred innovation questionnaire for hospital nurses.

    PubMed

    Huang, Ching-Yuan; Weng, Rhay-Hung; Wu, Tsung-Chin; Lin, Tzu-En; Hsu, Ching-Tai; Hung, Chiu-Hsia; Tsai, Yu-Chen

    2018-03-01

    Develop the patient-centred innovation questionnaire for hospital nurses and establish its validity and reliability. Patient-centred care has been adopted by health care managers in their efforts to improve health care quality. It is regarded as a core concept for developing innovation. A cross-sectional study was employed to collect data from hospital nurses in Taiwan. This study was divided into two stages: pilot study and main study. In the main study, 596 valid responses were collected. This study adopted reliability analysis, exploratory factor analysis, confirmatory factor analysis and selected nurse innovation scale as a criterion to test criterion-related validity. Five-dimension patient-centred innovation questionnaire was proposed: access and practicability, co-ordination and communication, sharing power and responsibility, care continuity, family and person focus. Each dimension demonstrated a reliability of 0.89-0.98. All dimensions had acceptable convergent and discriminate validity. The patient-centred innovation questionnaire and nurse innovation scale exhibited a significantly positive correlation. Patient-centred innovation questionnaire not only had a good theoretical basis but also had sufficient reliability and construct validity, and criterion-related validity. Patient-centred innovation questionnaire could give a measure for evaluating the implementation of patient-centred care and could be used as a management tool during the process of nurse innovation. © 2017 John Wiley & Sons Ltd.

  16. Validity of radiographic assessment of the knee joint space using automatic image analysis.

    PubMed

    Komatsu, Daigo; Hasegawa, Yukiharu; Kojima, Toshihisa; Seki, Taisuke; Ikeuchi, Kazuma; Takegami, Yasuhiko; Amano, Takafumi; Higuchi, Yoshitoshi; Kasai, Takehiro; Ishiguro, Naoki

    2016-09-01

    The present study investigated whether there were differences between automatic and manual measurements of the minimum joint space width (mJSW) on knee radiographs. Knee radiographs of 324 participants in a systematic health screening were analyzed using the following three methods: manual measurement of film-based radiographs (Manual), manual measurement of digitized radiographs (Digital), and automatic measurement of digitized radiographs (Auto). The mean mJSWs on the medial and lateral sides of the knees were determined using each method, and measurement reliability was evaluated using intra-class correlation coefficients. Measurement errors were compared between normal knees and knees with radiographic osteoarthritis. All three methods demonstrated good reliability, although the reliability was slightly lower with the Manual method than with the other methods. On the medial and lateral sides of the knees, the mJSWs were the largest in the Manual method and the smallest in the Auto method. The measurement errors of each method were significantly larger for normal knees than for radiographic osteoarthritis knees. The mJSW measurements are more accurate and reliable with the Auto method than with the Manual or Digital method, especially for normal knees. Therefore, the Auto method is ideal for the assessment of the knee joint space.

  17. Dynamic comparisons of piezoelectric ejecta diagnostics

    NASA Astrophysics Data System (ADS)

    Buttler, W. T.; Zellner, M. B.; Olson, R. T.; Rigg, P. A.; Hixson, R. S.; Hammerberg, J. E.; Obst, A. W.; Payton, J. R.; Iverson, A.; Young, J.

    2007-03-01

    We investigate the quantitative reliability and precision of three different piezoelectric technologies for measuring ejected areal mass from shocked surfaces. Specifically we performed ejecta measurements on Sn shocked at two pressures, P ≈215 and 235 kbar. The shock in the Sn was created by launching a impactor with a powder gun. We self-compare and cross-compare these measurements to assess the ability of these probes to precisely determine the areal mass ejected from a shocked surface. We demonstrate the precision of each technology to be good, with variabilities on the order of ±10%. We also discuss their relative accuracy.

  18. Precision manufacturing for clinical-quality regenerative medicines.

    PubMed

    Williams, David J; Thomas, Robert J; Hourd, Paul C; Chandra, Amit; Ratcliffe, Elizabeth; Liu, Yang; Rayment, Erin A; Archer, J Richard

    2012-08-28

    Innovations in engineering applied to healthcare make a significant difference to people's lives. Market growth is guaranteed by demographics. Regulation and requirements for good manufacturing practice-extreme levels of repeatability and reliability-demand high-precision process and measurement solutions. Emerging technologies using living biological materials add complexity. This paper presents some results of work demonstrating the precision automated manufacture of living materials, particularly the expansion of populations of human stem cells for therapeutic use as regenerative medicines. The paper also describes quality engineering techniques for precision process design and improvement, and identifies the requirements for manufacturing technology and measurement systems evolution for such therapies.

  19. Validation of Brief Multidimensional Spirituality/Religiousness Inventory (BMMRS) in Italian Adult Participants and in Participants with Medical Diseases.

    PubMed

    Vespa, Anna; Giulietti, Maria Velia; Spatuzzi, Roberta; Fabbietti, Paolo; Meloni, Cristina; Gattafoni, Pisana; Ottaviani, Marica

    2017-06-01

    This study aimed at assessing the reliability and construct validity of Brief Multidimensional Measure of Religiousness/Spirituality (BMMRS) on Italian sample. 353 Italian participants: 58.9% affected by different diseases and 41.1% healthy subjects. The results of descriptive statistics of internal consistency reliabilities (Chronbach's coefficient) of the BMMRS revealed a remarkable consistency and reliability of different scales DSE, SpC, SC, CSC, VB, SPY-WELL and a good Inter-Class Correlations ≥70 maintaining a good stability of the measures over the time. BMMRS is a useful inventory for the evaluation of the principal spiritual dimensions.

  20. The Impact of Patient Aggression on Carers Scale: instrument derivation and psychometric testing.

    PubMed

    Needham, Ian; Abderhalden, Chris; Halfens, Rudolph J G; Dassen, Theo; Haug, Hans-Joachim; Fischer, Joachim E

    2005-09-01

    Patient aggression towards carers constitutes a problem for patients and carers alike. Patients' aggressive behaviour often leads to adverse consequences for carers, especially nurses. Various extensive instruments have been developed to measure such adverse effects on carers. The 'Impact of Patient Aggression on Carers Scale' (IMPACS) is a short instrument intended for use in monitoring negative consequences of such incidents. The items of the IMPACS were derived basically from a review of the literature on negative effects of patient aggression on nurses. The IMPACS was administered to a convenience sample of nurses working on 14 psychiatric acute admission wards in the German speaking part of Switzerland. Factor analysis led to the exclusion of three of the original items and to an interpretable three-factor solution with all factors demonstrating eigen values higher than 1. The factors demonstrate moderate to good internal consistency. Canonical correlation analysis using the dimensions of the Maslach Burnout Inventory (MBI) produced a correlation coefficient of 0.457, thus demonstrating external reliability. In spite of some caveats such as possible response bias and the necessity of the investigation of the test-retest stability of the scale this study suggests that the IMPACS is a good measure of adverse effects and thus merits further development.

  1. Assessment of behavioral mechanisms maintaining encopresis: Virginia Encopresis-Constipation Apperception Test.

    PubMed

    Cox, Daniel J; Ritterband, Lee M; Quillian, Warren; Kovatchev, Boris; Morris, James; Sutphen, James; Borowitz, Stephen

    2003-09-01

    To develop and test a scale for parent and child, evaluating theoretical and clinical parameters relevant to children with encopresis. Encopretic children were hypothesized to have more bowel-specific, but not more generic, psychological problems, as compared with nonsymptomatic control children. In addition, mothers were also believed to be more discerning than children. The Virginia Encopresis-Constipation Apperception Test (VECAT) consists of 9 pairs of bowel-specific and 9 parallel generic drawings. Respondents selected the picture in each pair that best described them/their child. It was administered to encopretic children (N = 87), nonsymptomatic siblings (N = 27), and nonsymptomatic nonsiblings (N = 35). The mothers of all the participants also completed the VECAT. Encopretic children were retested 6 and 12 months posttreatment with Enhanced Toilet Training. The VECAT demonstrated good test-retest reliability and internal consistency. Encopretic children and their mothers reported more bowel-specific, but not more generic, problems. Bowel-specific scores improved significantly posttreatment only for those patients who demonstrated significant symptom improvement. Mothers were significantly more discerning than children. The VECAT is a reliable, valid, discriminating, and sensitive test. Bowel-specific problems appear to best differentiate children with and without encopresis.

  2. Psychometric evaluation of the fatigue severity scale for use in chronic hepatitis C.

    PubMed

    Kleinman, L; Zodet, M W; Hakim, Z; Aledort, J; Barker, C; Chan, K; Krupp, L; Revicki, D

    2000-01-01

    Evidence exists demonstrating that infection with hepatitis C virus impairs health-related quality of life, but less is known about the effect of fatigue, a common symptom, on everyday life. The psychometric properties of the fatigue severity scale (FSS) were explored to determine suitability as an outcome measure in clinical trials. The FSS includes nine items developed to measure disabling fatigue and a visual analog scale (VAS) to measure overall fatigue. Using baseline data from three clinical trials (n = 1225) involving chronic hepatitis C patients, scaling and psychometric characteristics of the FSS were assessed. The SF-36 was also used in the trials. Item response theory analysis demonstrated that the FSS items can be placed along a single homogenous domain, fatigue. Internal consistency reliability was 0.94. Test-retest reliability was 0.82 for the total score and 0.80 for the VAS. The total score and the VAS were significantly correlated with the SF-36 vitality subscale (r = -0.76 and r = -0.76 respectively). Correlations with other SF-36 subscales were moderate (r = -0.46 to r = -0.67, all p < 0.0001). In summary, the FSS possesses good psychometric properties.

  3. The reliability and validity of the Maryland Assessment of Recovery in Serious Mental Illness Scale.

    PubMed

    Drapalski, Amy L; Medoff, Deborah; Dixon, Lisa; Bellack, Alan

    2016-05-30

    The current study aims to further evaluate the psychometric properties of the Maryland Assessment of Recovery in Serious Mental Illness (MARS), a relatively new instrument designed to assess personal recovery status in individuals with serious mental illness. Two hundred and fifty individuals with serious mental illness receiving outpatient mental health treatment completed a baseline assessment which included the MARS and measures to assess recovery-related constructs, clinical outcomes, and social and community functioning. The MARS demonstrated excellent internal consistency and test-retest reliability. Good construct validity was evidenced by strong positive relationships between the MARS and recovery-related constructs (e.g. hope, empowerment, self-efficacy, and personal agency) and a strong negative relationship with self-stigma. Divergent validity was demonstrated by weaker relationships with cognitive and social functioning. The confirmatory factor analysis did not confirm the unitary factor structure found in previous research. Given the equivocal result of the CFA, additional exploratory work is needed to determine if a more complex factor structure is present. This study provides addition support for the psychometric soundness of the MARS and subsequently, its potential use as a measure of personal recovery status in people with serious mental illness. Published by Elsevier Ireland Ltd.

  4. Three-dimensional scapular kinematics during the throwing motion.

    PubMed

    Meyer, Kristin E; Saether, Erin E; Soiney, Emily K; Shebeck, Meegan S; Paddock, Keith L; Ludewig, Paula M

    2008-02-01

    Proper scapular motion is crucial for normal shoulder mechanics. Scapular motion affects glenohumeral joint function during throwing, yet little is known about this dynamic activity. Asymptomatic subjects (10 male and 10 female), ages 21 to 45, were analyzed. Electromagnetic surface sensors on the sternum, acromion, and humerus were used to collect 3-D motion data during three trials of low-velocity throwing. Scapular angular position data were described or five predetermined events throughout the throw corresponding with classic descriptions of throwing phases, and trial-to-trial reliability was determined. ANOVA compared scapular angles across events. Subjects demonstrated good to excellent reliability between trials of the throw (ICC 0.74-0.98). The scapula demonstrated a pattern of external rotation, upward rotation (peak of approx. 40 degrees), and poster humeral horizontal abduction. During the arm acceleration phase, the scapula moved toward greater internal rotation and began anteriorly tilting. At maximum humeral internal rotation, the scapula ended in internal rotation (55 degrees), upward rotation (20 degrees), and anterior tilting (3 degrees). Significant differences in scapular position (p<0.05) were identified across the throwing motion. Scapular data identify events in the throwing motion in which throwers may be more susceptible to shoulder pathologies related to abnormal scapular kinematics.

  5. Validity and reliability assessment of the Brazilian version of the game addiction scale (GAS).

    PubMed

    Lemos, Igor Lins; Cardoso, Adriana; Sougey, Everton Botelho

    2016-05-01

    The uncontrolled use of video games can be addictive. The Game Addiction Scale (GAS) is an instrument that was developed to assess this type of addiction. The GAS consists of 21 items that are divided into the following seven factors: salience, tolerance, mood modification, relapse, withdrawal, conflict and problems. This study assessed the convergent validity and reliability of the GAS according to measures of internal consistency and test-retest stability. Three hundred and eighty four students completed the GAS, the Internet Addiction Test (IAT), the Liebowitz Social Anxiety Scale (LSAS), the Beck Depression Inventory (BDI) and the Video Game Addiction Test (VAT). A subgroup of the participants (n=76) completed the GAS again after 30days to determine test-retest stability. The GAS demonstrated excellent internal consistency (Cronbach's alpha=0.92), was highly correlated with the VAT (r=0.883) and was moderately correlated with the BDI (r=0.358), the LSAS (r=0.326) and the IAT (r=0.454). In the Brazilian Portuguese population, the GAS shows good internal consistency. These data indicate that the GAS can be used to assess video game addiction due to its demonstrated psychometric validity. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. An analysis and demonstration of clock synchronization by VLBI. [Very Long Baseline Interferometry for Deep Space Net

    NASA Technical Reports Server (NTRS)

    Hurd, W. J.

    1974-01-01

    A prototype of a semi-real time system for synchronizing the Deep Space Net station clocks by radio interferometry was successfully demonstrated on August 30, 1972. The system utilized an approximate maximum likelihood estimation procedure for processing the data, thereby achieving essentially optimum time sync estimates for a given amount of data, or equivalently, minimizing the amount of data required for reliable estimation. Synchronization accuracies as good as 100 ns rms were achieved between Deep Space Stations 11 and 12, both at Goldstone, Calif. The accuracy can be improved by increasing the system bandwidth until the fundamental limitations due to baseline and source position uncertainties and atmospheric effects are reached. These limitations are under 10 ns for transcontinental baselines.

  7. Inter- and intraobserver reliability of the Rockwood classification in acute acromioclavicular joint dislocations.

    PubMed

    Schneider, M M; Balke, M; Koenen, P; Fröhlich, M; Wafaisade, A; Bouillon, B; Banerjee, M

    2016-07-01

    The reliability of the Rockwood classification, the gold standard for acute acromioclavicular (AC) joint separations, has not yet been tested. The purpose of this study was to investigate the reliability of visual and measured AC joint lesion grades according to the Rockwood classification. Four investigators (two shoulder specialists and two second-year residents) examined radiographs (bilateral panoramic stress and axial views) in 58 patients and graded the injury according to the Rockwood classification using the following sequence: (1) visual classification of the AC joint lesion, (2) digital measurement of the coracoclavicular distance (CCD) and the horizontal dislocation (HD) with Osirix Dicom Viewer (Pixmeo, Switzerland), (3) classification of the AC joint lesion according to the measurements and (4) repetition of (1) and (2) after repeated anonymization by an independent physician. Visual and measured Rockwood grades as well as the CCD and HD of every patient were documented, and a CC index was calculated (CCD injured/CCD healthy). All records were then used to evaluate intra- and interobserver reliability. The disagreement between visual and measured diagnosis ranged from 6.9 to 27.6 %. Interobserver reliability for visual diagnosis was good (0.72-0.74) and excellent (0.85-0.93) for measured Rockwood grades. Intraobserver reliability was good to excellent (0.67-0.93) for visual diagnosis and excellent for measured diagnosis (0.90-0.97). The correlations between measurements of the axial view varied from 0.68 to 0.98 (good to excellent) for interobserver reliability and from 0.90 to 0.97 (excellent) for intraobserver reliability. Bilateral panoramic stress and axial radiographs are reliable examinations for grading AC joint injuries according to Rockwood's classification. Clinicians of all experience levels can precisely classify AC joint lesions according to the Rockwood classification. We recommend to grade acute ACG lesions by performing a digital measurement instead of a sole visual diagnosis because of the higher intra- and interobserver reliability. Case series, Level IV.

  8. Comparative ex vivo evaluation of two electronic percussive testing devices measuring the stability of dental implants.

    PubMed

    Geckili, Onur; Bilhan, Hakan; Cilingir, Altug; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan

    2014-12-01

    A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra- and interobserver reliability of the wireless EPT device. Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra- and interobserver reliability of the wireless EPT device was evaluated. Statistically significant differences (P <0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P <0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter- and intraobserver reliability is good and acceptable.

  9. Translation, cross-cultural adaptation and psychometric properties of the Nepali versions of numerical pain rating scale and global rating of change.

    PubMed

    Sharma, Saurab; Palanchoke, Joshna; Reed, Darren; Haxby Abbott, J

    2017-12-04

    Pain intensity and patients' impression of global improvement are widely used patient-reported outcome measures (PROMs) in clinical practice and research. They are commonly assessed using the Numerical Pain Rating Scale (NPRS) and Global Rating of Change (GROC) questionnaires. The GROC is essential as an anchor for evaluating the psychometric properties of PROMs. Both of these PROMs are translated to many languages and have shown excellent psychometric properties. Their availability in Nepali would facilitate pain research and cross-cultural comparison of research findings. Therefore, the objectives of this study were to translate and cross-culturally adapt the NPRS and GROC into Nepali and to assess the psychometric properties of the Nepali version of the NPRS (NPRS-NP). After translating and cross-culturally adapting the NPRS and GROC into Nepali using recommended guidelines, NPRS-NP was administered to 104 individuals with musculoskeletal pain twice. The Nepali version of the GROC (GROC-NP) was administered at the follow-up for anchor-based assessment. (1) Test-retest reliability and minimum detectable change (MDC) among the stable group, (2) construct validity (by single sample t-test within the improved group and independent sample t-test between groups), and (3) concurrent validity were assessed. Receiver operating characteristic (ROC) curves were plotted to determine the responsiveness of the NPRS-NP using the area under the curve (AUC), and minimum important changes (MIC) for small, medium and large improvements. Significant cultural adaptations were required to obtain relevant Nepali versions of both the NPRS and GROC. The NPRS-NP showed excellent test-retest reliability and a MDC of 1.13 points. NPRS-NP demonstrated a good construct validity by significant within-group difference in mean of NPRS score- t(63)= 7.57, P < 0.001 and statistically significant difference of mean score- t(98)= -4.24, P < .001 between the stable and improved groups. It demonstrated moderate concurrent correlation with the GROC-NP; r = 0.43, P < 0.01. Responsiveness of the NPRS-NP was shown at three levels with AUC = 0.68-0.82, and MIC = 1.17-1.33. The NPRS and GROC were successfully translated and culturally adapted into Nepali. The NPRS-NP demonstrated good reliability, validity and responsiveness in assessing musculoskeletal pain intensity in a Nepali population.

  10. Validation of the cardiac health behavior scale for Korean adults with cardiovascular risks or diseases.

    PubMed

    Song, Rhayun; Oh, Hyunkyoung; Ahn, Sukhee; Moorhead, Sue

    2018-02-01

    The purpose of this study was to validate the Cardiac Health Behavior Scale for Korean adults (CHB-K) to determine its validity and reliability. Cardiovascular diseases (CVDs) are one of the most important chronic diseases due to their high prevalence and mortality rates. Patients with cardiovascular risks or diseases need to perform appropriate cardiac health behaviors that help to prevent the progression of the disease and improve their health status. This secondary analysis obtained data from two clinical trials of cardiac rehabilitation. Data from 298 patients with cardiovascular risks or diseases were analyzed for validation. Data analyses included correlation coefficients, t-tests, and exploratory and confirmatory factor analyses using SPSS (version WIN 22.0) and AMOS (version 20.0). The Self-Efficacy Scale was used to assess convergent validity, while reliability was assessed using Cronbach's alpha coefficients. Five main factors were verified: health responsibility, physical activity, diet habit (eating habit and food choice), stress management, and smoking cessation. A set of 21 items from the 25-item scale was verified after performing item analysis, factor analyses, and critical evaluation of the statistical results. The 21-item CHB-K (CHB-K21) exhibited acceptable validity, and the model of the CHB-K21 provided a good fit to the data. Most of the factors were found to be moderately correlated with SES scores (r=0.45-0.52, p<0.001). The CHB-K21 also demonstrated acceptable reliability (Cronbach's alpha=0.83). The CHB-K21 demonstrates strong validity and reliability. It can be used to assess cardiac health behaviors in Korean adults with cardiovascular risks or diseases. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Construct Validity of the Societal Outreach Scale (SOS).

    PubMed

    Fike, David S; Denton, Jason; Walk, Matt; Kish, Jennifer; Gorman, Ira

    2018-04-01

    The American Physical Therapy Association (APTA) has been working toward a vision of increasing professional focus on societal-level health. However, performance of social responsibility and related behaviors by physical therapists remain relatively poorly integrated into practice. Promoting a focus on societal outreach is necessary for all health care professionals to impact the health of their communities. The objective was to document the validity of the 14-item Societal Outreach Scale (SOS) for use with practicing physical therapists. This study used a cross-sectional survey. The SOS was transmitted via email to all therapists who were licensed and practicing in 10 states in the United States that were purposefully selected to assure a broad representation. A sample of 2612 usable responses was received. Factor analysis was applied to assess construct validity of the instrument. Of alternate models, a 3-factor model best demonstrated goodness of fit with the sample data according to conventional indices (standardized root mean squared residual = .03, comparative fit index .96, root mean square error of approximation = .06). The 3 factors measured by the SOS were labeled Societal-Level Health Advocacy, Community Engagement/Social Integration, and Political Engagement. Internal consistency reliability was 0.7 for all factors. The 3-factor SOS demonstrated acceptable validity and reliability. Though the sample included a broad representation of physical therapists, this was a single cross-sectional study. Additional confirmatory factor analysis, reliability testing, and word refinement of the tool are warranted. Given the construct validity and reliability of the 3-factor SOS, it is recommended for use as a validated instrument to measure physical therapists' performance of social responsibility and related behaviors.

  12. Inter-vender and test-retest reliabilities of resting-state functional magnetic resonance imaging: Implications for multi-center imaging studies.

    PubMed

    An, Hyeong Su; Moon, Won-Jin; Ryu, Jae-Kyun; Park, Ju Yeon; Yun, Won Sung; Choi, Jin Woo; Jahng, Geon-Ho; Park, Jang-Yeon

    2017-12-01

    This prospective multi-center study aimed to evaluate the inter-vendor and test-retest reliabilities of resting-state functional magnetic resonance imaging (RS-fMRI) by assessing the temporal signal-to-noise ratio (tSNR) and functional connectivity. Study included 10 healthy subjects and each subject was scanned using three 3T MR scanners (GE Signa HDxt, Siemens Skyra, and Philips Achieva) in two sessions. The tSNR was calculated from the time course data. Inter-vendor and test-retest reliabilities were assessed with intra-class correlation coefficients (ICCs) derived from variant component analysis. Independent component analysis was performed to identify the connectivity of the default-mode network (DMN). In result, the tSNR for the DMN was not significantly different among the GE, Philips, and Siemens scanners (P=0.638). In terms of vendor differences, the inter-vendor reliability was good (ICC=0.774). Regarding the test-retest reliability, the GE scanner showed excellent correlation (ICC=0.961), while the Philips (ICC=0.671) and Siemens (ICC=0.726) scanners showed relatively good correlation. The DMN pattern of the subjects between the two sessions for each scanner and between three scanners showed the identical patterns of functional connectivity. The inter-vendor and test-retest reliabilities of RS-fMRI using different 3T MR scanners are good. Thus, we suggest that RS-fMRI could be used in multicenter imaging studies as a reliable imaging marker. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Validity and Reliability of the Upper Extremity Work Demands Scale.

    PubMed

    Jacobs, Nora W; Berduszek, Redmar J; Dijkstra, Pieter U; van der Sluis, Corry K

    2017-12-01

    Purpose To evaluate validity and reliability of the upper extremity work demands (UEWD) scale. Methods Participants from different levels of physical work demands, based on the Dictionary of Occupational Titles categories, were included. A historical database of 74 workers was added for factor analysis. Criterion validity was evaluated by comparing observed and self-reported UEWD scores. To assess structural validity, a factor analysis was executed. For reliability, the difference between two self-reported UEWD scores, the smallest detectable change (SDC), test-retest reliability and internal consistency were determined. Results Fifty-four participants were observed at work and 51 of them filled in the UEWD twice with a mean interval of 16.6 days (SD 3.3, range = 10-25 days). Criterion validity of the UEWD scale was moderate (r = .44, p = .001). Factor analysis revealed that 'force and posture' and 'repetition' subscales could be distinguished with Cronbach's alpha of .79 and .84, respectively. Reliability was good; there was no significant difference between repeated measurements. An SDC of 5.0 was found. Test-retest reliability was good (intraclass correlation coefficient for agreement = .84) and all item-total correlations were >.30. There were two pairs of highly related items. Conclusion Reliability of the UEWD scale was good, but criterion validity was moderate. Based on current results, a modified UEWD scale (2 items removed, 1 item reworded, divided into 2 subscales) was proposed. Since observation appeared to be an inappropriate gold standard, we advise to investigate other types of validity, such as construct validity, in further research.

  14. Discrete Time Rescaling Theorem: Determining Goodness of Fit for Discrete Time Statistical Models of Neural Spiking

    PubMed Central

    Haslinger, Robert; Pipa, Gordon; Brown, Emery

    2010-01-01

    One approach for understanding the encoding of information by spike trains is to fit statistical models and then test their goodness of fit. The time rescaling theorem provides a goodness of fit test consistent with the point process nature of spike trains. The interspike intervals (ISIs) are rescaled (as a function of the model’s spike probability) to be independent and exponentially distributed if the model is accurate. A Kolmogorov Smirnov (KS) test between the rescaled ISIs and the exponential distribution is then used to check goodness of fit. This rescaling relies upon assumptions of continuously defined time and instantaneous events. However spikes have finite width and statistical models of spike trains almost always discretize time into bins. Here we demonstrate that finite temporal resolution of discrete time models prevents their rescaled ISIs from being exponentially distributed. Poor goodness of fit may be erroneously indicated even if the model is exactly correct. We present two adaptations of the time rescaling theorem to discrete time models. In the first we propose that instead of assuming the rescaled times to be exponential, the reference distribution be estimated through direct simulation by the fitted model. In the second, we prove a discrete time version of the time rescaling theorem which analytically corrects for the effects of finite resolution. This allows us to define a rescaled time which is exponentially distributed, even at arbitrary temporal discretizations. We demonstrate the efficacy of both techniques by fitting Generalized Linear Models (GLMs) to both simulated spike trains and spike trains recorded experimentally in monkey V1 cortex. Both techniques give nearly identical results, reducing the false positive rate of the KS test and greatly increasing the reliability of model evaluation based upon the time rescaling theorem. PMID:20608868

  15. Discrete time rescaling theorem: determining goodness of fit for discrete time statistical models of neural spiking.

    PubMed

    Haslinger, Robert; Pipa, Gordon; Brown, Emery

    2010-10-01

    One approach for understanding the encoding of information by spike trains is to fit statistical models and then test their goodness of fit. The time-rescaling theorem provides a goodness-of-fit test consistent with the point process nature of spike trains. The interspike intervals (ISIs) are rescaled (as a function of the model's spike probability) to be independent and exponentially distributed if the model is accurate. A Kolmogorov-Smirnov (KS) test between the rescaled ISIs and the exponential distribution is then used to check goodness of fit. This rescaling relies on assumptions of continuously defined time and instantaneous events. However, spikes have finite width, and statistical models of spike trains almost always discretize time into bins. Here we demonstrate that finite temporal resolution of discrete time models prevents their rescaled ISIs from being exponentially distributed. Poor goodness of fit may be erroneously indicated even if the model is exactly correct. We present two adaptations of the time-rescaling theorem to discrete time models. In the first we propose that instead of assuming the rescaled times to be exponential, the reference distribution be estimated through direct simulation by the fitted model. In the second, we prove a discrete time version of the time-rescaling theorem that analytically corrects for the effects of finite resolution. This allows us to define a rescaled time that is exponentially distributed, even at arbitrary temporal discretizations. We demonstrate the efficacy of both techniques by fitting generalized linear models to both simulated spike trains and spike trains recorded experimentally in monkey V1 cortex. Both techniques give nearly identical results, reducing the false-positive rate of the KS test and greatly increasing the reliability of model evaluation based on the time-rescaling theorem.

  16. Validation of a Dry Model for Assessing the Performance of Arthroscopic Hip Labral Repair.

    PubMed

    Phillips, Lisa; Cheung, Jeffrey J H; Whelan, Daniel B; Murnaghan, Michael Lucas; Chahal, Jas; Theodoropoulos, John; Ogilvie-Harris, Darrell; Macniven, Ian; Dwyer, Tim

    2017-07-01

    Arthroscopic hip labral repair is a technically challenging and demanding surgical technique with a steep learning curve. Arthroscopic simulation allows trainees to develop these skills in a safe environment. The purpose of this study was to evaluate the use of a combination of assessment ratings for the performance of arthroscopic hip labral repair on a dry model. Cross-sectional study; Level of evidence, 3. A total of 47 participants including orthopaedic surgery residents (n = 37), sports medicine fellows (n = 5), and staff surgeons (n = 5) performed arthroscopic hip labral repair on a dry model. Prior arthroscopic experience was noted. Participants were evaluated by 2 orthopaedic surgeons using a task-specific checklist, the Arthroscopic Surgical Skill Evaluation Tool (ASSET), task completion time, and a final global rating scale. All procedures were video-recorded and scored by an orthopaedic fellow blinded to the level of training of each participant. The internal consistency/reliability (Cronbach alpha) using the total ASSET score for the procedure was high (intraclass correlation coefficient > 0.9). One-way analysis of variance for the total ASSET score demonstrated a difference between participants based on the level of training ( F 3,43 = 27.8, P < .001). A good correlation was seen between the ASSET score and previous exposure to arthroscopic procedures ( r = 0.52-0.73, P < .001). The interrater reliability for the ASSET score was excellent (>0.9). The results of this study demonstrate that the use of dry models to assess the performance of arthroscopic hip labral repair by trainees is both valid and reliable. Further research will be required to demonstrate a correlation with performance on cadaveric specimens or in the operating room.

  17. Psychometric validation and reliability analysis of a Spanish version of the patient satisfaction with cancer-related care measure: a patient navigation research program study.

    PubMed

    Jean-Pierre, Pascal; Fiscella, Kevin; Winters, Paul C; Paskett, Electra; Wells, Kristen; Battaglia, Tracy

    2012-09-01

    Patient satisfaction (PS), a key measure of quality of cancer care, is a core study outcome of the multi-site National Cancer Institute-funded Patient Navigation Research Program. Despite large numbers of underserved monolingual Spanish speakers (MSS) residing in USA, there is no validated Spanish measure of PS that spans the whole spectrum of cancer-related care. The present study reports on the validation of the Patient Satisfaction with Cancer Care (PSCC) measure for Spanish (PSCC-Sp) speakers receiving diagnostic and therapeutic cancer-related care. Original PSCC items were professionally translated and back translated to ensure cultural appropriateness, meaningfulness, and equivalence. Then, the resulting 18-item PSCC-Sp measure was administered to 285 MSS. We evaluated latent structure and internal consistency of the PSCC-Sp using principal components analysis (PCA) and Cronbach coefficient alpha (α). We used correlation analyses to demonstrate divergence and convergence of the PSCC-Sp with a Spanish version of the Patient Satisfaction with Interpersonal Relationship with Navigator (PSN-I-Sp) measure and patients' demographics. The PCA revealed a coherent set of items that explicates 47% of the variance in PS. Reliability assessment demonstrated that the PSCC-Sp had high internal consistency (α = 0.92). The PSCC-Sp demonstrated good face validity and convergent and divergent validities as indicated by moderate correlations with the PSN-I-Sp (p = 0.003) and nonsignificant correlations with marital status and household income (all p(s) > 0.05). The PSCC-Sp is a valid and reliable measure of PS and should be tested in other MSS populations.

  18. Perceptual and Acoustic Analyses of Good Voice Quality in Male Radio Performers.

    PubMed

    Warhurst, Samantha; Madill, Catherine; McCabe, Patricia; Ternström, Sten; Yiu, Edwin; Heard, Robert

    2017-03-01

    Good voice quality is an asset to professional voice users, including radio performers. We examined whether (1) voices could be reliably categorized as good for the radio and (2) these categories could be predicted using acoustic measures. Male radio performers (n = 24) and age-matched male controls performed "The Rainbow Passage" as if presenting on the radio. Voice samples were rated using a three-stage paired-comparison paradigm by 51 naive listeners and perceptual categories were identified (Study 1), and then analyzed for fundamental frequency, long-term average spectrum, cepstral peak prominence, and pause or spoken-phrase duration (Study 2). Study 1: Good inter-judge reliability was found for perceptual judgments of the best 15 voices (good for radio category, 14/15 = radio performers), but agreement on the remaining 33 voices (unranked category) was poor. Study 2: Discriminant function analyses showed that the SD standard deviation of sounded portion duration, equivalent sound level, and smoothed cepstral peak prominence predicted membership of categories with moderate accuracy (R 2  = 0.328). Radio performers are heterogeneous for voice quality; good voice quality was judged reliably in only 14 out of 24 radio performers. Current acoustic analyses detected some of the relevant signal properties that were salient in these judgments. More refined perceptual analysis and the use of other perceptual methods might provide more information on the complex nature of judging good voices. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  19. Testing fine motor coordination via telehealth: effects of video characteristics on reliability and validity.

    PubMed

    Hoenig, Helen M; Amis, Kristopher; Edmonds, Carol; Morgan, Michelle S; Landerman, Lawrence; Caves, Kevin

    2017-01-01

    Background There is limited research about the effects of video quality on the accuracy of assessments of physical function. Methods A repeated measures study design was used to assess reliability and validity of the finger-nose test (FNT) and the finger-tapping test (FTT) carried out with 50 veterans who had impairment in gross and/or fine motor coordination. Videos were scored by expert raters under eight differing conditions, including in-person, high definition video with slow motion review and standard speed videos with varying bit rates and frame rates. Results FTT inter-rater reliability was excellent with slow motion video (ICC 0.98-0.99) and good (ICC 0.59) under the normal speed conditions. Inter-rater reliability for FNT 'attempts' was excellent (ICC 0.97-0.99) for all viewing conditions; for FNT 'misses' it was good to excellent (ICC 0.89) with slow motion review but substantially worse (ICC 0.44) on the normal speed videos. FTT criterion validity (i.e. compared to slow motion review) was excellent (β = 0.94) for the in-person rater and good ( β = 0.77) on normal speed videos. Criterion validity for FNT 'attempts' was excellent under all conditions ( r ≥ 0.97) and for FNT 'misses' it was good to excellent under all conditions ( β = 0.61-0.81). Conclusions In general, the inter-rater reliability and validity of the FNT and FTT assessed via video technology is similar to standard clinical practices, but is enhanced with slow motion review and/or higher bit rate.

  20. Examining the reliability and validity of a modified version of the International Physical Activity Questionnaire, long form (IPAQ-LF) in Nigeria: a cross-sectional study.

    PubMed

    Oyeyemi, Adewale L; Bello, Umar M; Philemon, Saratu T; Aliyu, Habeeb N; Majidadi, Rebecca W; Oyeyemi, Adetoyeje Y

    2014-12-01

    To investigate the reliability and an aspect of validity of a modified version of the long International Physical Activity Questionnaire (Hausa IPAQ-LF) in Nigeria. Cross-sectional study, examining the reliability and construct validity of the Hausa IPAQ-LF compared with anthropometric and biological variables. Metropolitan Maiduguri, the capital city of Borno State in Nigeria. 180 Nigerian adults (50% women) with a mean age of 35.6 (SD=10.3) years, recruited from neighbourhoods with diverse socioeconomic status and walkability. Domains (domestic physical activity (PA), occupational PA, leisure-time PA, active transportation and sitting time) and intensities of PA (vigorous, moderate and walking) were measured with the Hausa IPAQ-LF on two different occasions, 8 days apart. Outcomes for construct validity were measured body mass index (BMI), systolic blood pressure (SBP) and diastolic blood pressure (DBP). The Hausa IPAQ-LF demonstrated good test-retest reliability (intraclass correlation coefficient, ICC>75) for total PA (ICC=0.79, 95% CI 0.65 to 0.82), occupational PA (ICC=0.77, 95% CI 0.68 to 0.82), active transportation (ICC=0.82, 95% CI 0.75 to 0.87) and vigorous intensity activities (ICC=0.82, 95% CI 0.76 to 0.87). Reliability was substantially higher for total PA (ICC=0.80), occupational PA (ICC=0.78), leisure-time PA (ICC=0.75) and active transportation (ICC=0.80) in men than in women, but domestic PA (ICC=0.38) and sitting time (ICC=0.71) demonstrated more substantial reliability coefficients in women than in men. For the construct validity, domestic PA was significantly related mainly with SBP (r=-0.27) and DBP (r=-0.17), and leisure-time PA and total PA were significantly related only with SBP (r=-0.16) and BMI (r=-0.29), respectively. Similarly, moderate-intensity PA was mainly related with SBP (r=-0.16, p<0.05) and DBP (r=-0.21, p<0.01), but vigorous-intensity PA was only related with BMI (r=-0.11, p<0.05). The modified Hausa IPAQ-LF demonstrated sufficient evidence of test-retest reliability and may be valid for assessing context specific PA behaviours of adults in Nigeria. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Biomaterial properties evaluation of poly(vinyl acetate- alt-maleic anhydride)/chitosan nanocapsules

    NASA Astrophysics Data System (ADS)

    Raţă, Delia Mihaela; Popa, Marcel; Chailan, Jean-François; Zamfir, Carmen Lăcrămioara; Peptu, Cătălina Anişoara

    2014-08-01

    Nanocapsules with diameter around 100 nm based on a natural polymer (chitosan) and a synthetic polymer poly(vinyl acetate- alt-maleic anhydride) [poly(MAVA)] by interfacial condensation method were prepared. The present study proposes a new type of biocompatible nanocapsules based on poly(vinyl acetate- alt-maleic anhydride-chitosan) (MCS) able to become a reliable support for inclusion and release of drugs. The spherical shape of the nanocapsules was evidenced by scanning electron microscopy. Nanocapsules presented a good Norfloxacin loading and release capacity. Haemocompatibility tests have demonstrated that the nanocapsules present a low toxicity and a good compatibility with sanguine medium. The biocompatibility properties of the nanocapsules after their intraperitoneal administration in rats were evidenced by histopathological examination of different organs (brain, liver, kidney, and lung). The results are encouraging and the nanocapsules can be used as controlled drug delivery systems.

  2. Feasibility of a Low-Cost, Interactive Gaming System to Assess Balance in Older Women.

    PubMed

    Hall, Courtney D; Clevenger, Carolyn K; Wolf, Rachel A; Lin, James S; Johnson, Theodore M; Wolf, Steven L

    2016-01-01

    The use of low-cost interactive game technology for balance rehabilitation has become more popular recently, with generally good outcomes. Very little research has been undertaken to determine whether this technology is appropriate for balance assessment. The Wii balance board has good reliability and is comparable to a research-grade force plate; however, recent studies examining the relationship between Wii Fit games and measures of balance and mobility demonstrate conflicting findings. This study found that the Wii Fit was feasible for community-dwelling older women to safely use the balance board and quickly learn the Wii Fit games. The Ski Slalom game scores were strongly correlated with several balance and mobility measures, whereas Table Tilt game scores were not. Based on these findings, the Ski Slalom game may have utility in the evaluation of balance problems in community-dwelling older adults.

  3. Two-dimensional dopant profiling of gallium nitride p-n junctions by scanning capacitance microscopy

    NASA Astrophysics Data System (ADS)

    Lamhamdi, M.; Cayrel, F.; Frayssinet, E.; Bazin, A. E.; Yvon, A.; Collard, E.; Cordier, Y.; Alquier, D.

    2016-04-01

    Two-dimensional imaging of dopant profiles for n and p-type regions are relevant for the development of new power semiconductors, especially for gallium nitride (GaN) for which classical profiling techniques are not adapted. This is a challenging task since it needs a technique with simultaneously good sensitivity, high spatial resolution and high dopant gradient resolution. To face these challenges, scanning capacitance microscopy combined with Atomic Force Microscopy is a good candidate, presenting reproducible results, as demonstrated in literature. In this work, we attempt to distinguish reliably and qualitatively the various doping concentrations and type at p-n and unipolar junctions. For both p-n and unipolar junctions three kinds of samples were prepared and measured separately. The space-charge region of the p-n metallurgical junction, giving rise to different contrasts under SCM imaging, is clearly observed, enlightening the interest of the SCM technique.

  4. Assessing Anxiety in Youth with the Multidimensional Anxiety Scale for Children (MASC)

    PubMed Central

    Wei, Chiaying; Hoff, Alexandra; Villabø, Marianne A.; Peterman, Jeremy; Kendall, Philip C.; Piacentini, John; McCracken, James; Walkup, John T.; Albano, Anne Marie; Rynn, Moira; Sherrill, Joel; Sakolsky, Dara; Birmaher, Boris; Ginsburg, Golda; Keaton, Courtney; Gosch, Elizabeth; Compton, Scott N.; March, John

    2013-01-01

    The present study examined the psychometric properties, including discriminant validity and clinical utility, of the youth self-report and parent-report forms of the Multidimensional Anxiety Scale for Children (MASC) among youth with anxiety disorders. The sample included parents and youth (N= 488, 49.6% male) ages 7 – 17 who participated in the Child/Adolescent Anxiety Multimodal Study (CAMS). Although the typical low agreement between parent and youth self-reports was found, the MASC evidenced good internal reliability across MASC subscales and informants. The main MASC subscales (i.e., Physical Symptoms, Harm Avoidance, Social Anxiety, and Separation/Panic) were examined. The Social Anxiety and Separation/Panic subscales were found to be significantly predictive of the presence and severity of social phobia and separation anxiety disorder, respectively. Using multiple informants improved the accuracy of prediction. The MASC subscales demonstrated good psychometric properties and clinical utilities in identifying youth with anxiety disorders. PMID:23845036

  5. Comparison of Digital Rectal and Microchip Transponder Thermometry in Ferrets (Mustela putorius furo)

    PubMed Central

    Maxwell, Branden M; Brunell, Marla K; Olsen, Cara H; Bentzel, David E

    2016-01-01

    Body temperature is a common physiologic parameter measured in both clinical and research settings, with rectal thermometry being implied as the ‘gold standard.’ However, rectal thermometry usually requires physical or chemical restraint, potentially causing falsely elevated readings due to animal stress. A less stressful method may eliminate this confounding variable. The current study compared 2 types of digital rectal thermometers—a calibrated digital thermometer and a common digital thermometer—with an implantable subcutaneous transponder microchip. Microchips were implanted subcutaneously between the shoulder blades of 16 ferrets (8 male, 8 female), and temperatures were measured twice from the microchip reader and once from each of the rectal thermometers. Results demonstrated the microchip temperature readings had very good to good correlation and agreement to those from both of the rectal thermometers. This study indicates that implantable temperature-sensing microchips are a reliable alternative to rectal thermometry for monitoring body temperature in ferrets. PMID:27177569

  6. Intra- and Interobserver Reliability of Three Classification Systems for Hallux Rigidus.

    PubMed

    Dillard, Sarita; Schilero, Christina; Chiang, Sharon; Pham, Peter

    2018-04-18

    There are over ten classification systems currently used in the staging of hallux rigidus. This results in confusion and inconsistency with radiographic interpretation and treatment. The reliability of hallux rigidus classification systems has not yet been tested. The purpose of this study was to evaluate intra- and interobserver reliability using three commonly used classifications for hallux rigidus. Twenty-one plain radiograph sets were presented to ten ACFAS board-certified foot and ankle surgeons. Each physician classified each radiograph based on clinical experience and knowledge according to the Regnauld, Roukis, and Hattrup and Johnson classification systems. The two-way mixed single-measure consistency intraclass correlation was used to calculate intra- and interrater reliability. The intrarater reliability of individual sets for the Roukis and Hattrup and Johnson classification systems was "fair to good" (Roukis, 0.62±0.19; Hattrup and Johnson, 0.62±0.28), whereas the intrarater reliability of individual sets for the Regnauld system bordered between "fair to good" and "poor" (0.43±0.24). The interrater reliability of the mean classification was "excellent" for all three classification systems. Conclusions Reliable and reproducible classification systems are essential for treatment and prognostic implications in hallux rigidus. In our study, Roukis classification system had the best intrarater reliability. Although there are various classification systems for hallux rigidus, our results indicate that all three of these classification systems show reliability and reproducibility.

  7. Aiming for excellence - A simulation-based study on adapting and testing an instrument for developing non-technical skills in Norwegian student nurse anaesthetists.

    PubMed

    Flynn, Fiona M; Sandaker, Kjersti; Ballangrud, Randi

    2017-01-01

    There is increasing focus on building safety into anaesthesia practice, with excellence in anaesthesia as an aspirational goal. Non-technical skills are an important factor in excellence and improved patient safety, though there have been few systematic attempts at integrating them into anaesthesia nursing education. This study aimed to test the reliability of NANTS-no, a specially adapted behavioural marker system for nurse anaesthetists in Norway, and explore the development of non-technical skills in student nurse anaesthetists. The pre-test post-test design incorporated a 10-week simulation-based programme, where non-technical skills in 14 student nurse anaesthetists were rated on three different occasions during high-fidelity simulation, before and after taking part in a training course. NANTS-no demonstrated high overall inter-rater reliability (ICC = 0.91), high test-retest reliability (ICC = 0.94) and good internal consistency (Cronbach's α of 0.85-0.92). A significant improvement was demonstrated across all categories of non-technical skills, with greatest improvements between the first and third and second and third sessions. There was also a significant improvement in two categories between the first and second sessions. NANTS-no is therefore suitable for assessing non-technical skills during simulation training in anaesthesia nursing education. More research is needed to validate its use in clinical practice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Switching by Domain-Wall Automotion in Asymmetric Ferromagnetic Rings

    NASA Astrophysics Data System (ADS)

    Mawass, Mohamad-Assaad; Richter, Kornel; Bisig, Andre; Reeve, Robert M.; Krüger, Benjamin; Weigand, Markus; Stoll, Hermann; Krone, Andrea; Kronast, Florian; Schütz, Gisela; Kläui, Mathias

    2017-04-01

    Spintronic applications based on magnetic domain-wall (DW) motion, such as magnetic data storage, sensors, and logic devices, require approaches to reliably manipulate the magnetization in nanowires. In this paper, we report the direct dynamic experimental visualization of reliable switching from the onion to the vortex state by DW automotion at zero field in asymmetric ferromagnetic rings using a uniaxial field pulse. Employing time-resolved x-ray microscopy, we demonstrate that depending on the detailed spin structure of the DWs and the size and geometry of the rings, the automotive propagation can be tailored during the DW relaxation from the higher-energy onion state to the energetically favored vortex state, where both DWs annihilate. Our measurements show DW automotion with an average velocity of about 60 m /s , which is a significant speed for spintronic devices. Such motion is mostly governed by local forces resulting from the geometry variations in the device. A closer study of the annihilation process via micromagnetic simulations reveals that a new vortex is nucleated in between the two initial walls. We demonstrate that the annihilation of DWs through automotion in our scheme always occurs with the detailed topological nature of the walls influencing only the DW dynamics on a local scale. The simulations show good quantitative agreement with our experimental results. These findings shed light on a robust and reliable switching process of the onion state in ferromagnetic rings, which paves the way for further optimization of these devices.

  9. Specificity of reliable change models and review of the within-subjects standard deviation as an error term.

    PubMed

    Hinton-Bayre, Anton D

    2011-02-01

    There is an ongoing debate over the preferred method(s) for determining the reliable change (RC) in individual scores over time. In the present paper, specificity comparisons of several classic and contemporary RC models were made using a real data set. This included a more detailed review of a new RC model recently proposed in this journal, that used the within-subjects standard deviation (WSD) as the error term. It was suggested that the RC(WSD) was more sensitive to change and theoretically superior. The current paper demonstrated that even in the presence of mean practice effects, false-positive rates were comparable across models when reliability was good and initial and retest variances were equivalent. However, when variances differed, discrepancies in classification across models became evident. Notably, the RC using the WSD provided unacceptably high false-positive rates in this setting. It was considered that the WSD was never intended for measuring change in this manner. The WSD actually combines systematic and error variance. The systematic variance comes from measurable between-treatment differences, commonly referred to as practice effect. It was further demonstrated that removal of the systematic variance and appropriate modification of the residual error term for the purpose of testing individual change yielded an error term already published and criticized in the literature. A consensus on the RC approach is needed. To that end, further comparison of models under varied conditions is encouraged.

  10. Methods of Measurement in epidemiology: Sedentary Behaviour

    PubMed Central

    Atkin, Andrew J; Gorely, Trish; Clemes, Stacy A; Yates, Thomas; Edwardson, Charlotte; Brage, Soren; Salmon, Jo; Marshall, Simon J; Biddle, Stuart JH

    2012-01-01

    Background Research examining sedentary behaviour as a potentially independent risk factor for chronic disease morbidity and mortality has expanded rapidly in recent years. Methods We present a narrative overview of the sedentary behaviour measurement literature. Subjective and objective methods of measuring sedentary behaviour suitable for use in population-based research with children and adults are examined. The validity and reliability of each method is considered, gaps in the literature specific to each method identified and potential future directions discussed. Results To date, subjective approaches to sedentary behaviour measurement, e.g. questionnaires, have focused predominantly on TV viewing or other screen-based behaviours. Typically, such measures demonstrate moderate reliability but slight to moderate validity. Accelerometry is increasingly being used for sedentary behaviour assessments; this approach overcomes some of the limitations of subjective methods, but detection of specific postures and postural changes by this method is somewhat limited. Instruments developed specifically for the assessment of body posture have demonstrated good reliability and validity in the limited research conducted to date. Miniaturization of monitoring devices, interoperability between measurement and communication technologies and advanced analytical approaches are potential avenues for future developments in this field. Conclusions High-quality measurement is essential in all elements of sedentary behaviour epidemiology, from determining associations with health outcomes to the development and evaluation of behaviour change interventions. Sedentary behaviour measurement remains relatively under-developed, although new instruments, both objective and subjective, show considerable promise and warrant further testing. PMID:23045206

  11. A preliminary examination of the validity and reliability of a new brief rating scale for symptom domains of psychosis: Brief Evaluation of Psychosis Symptom Domains (BE-PSD).

    PubMed

    Takeuchi, Hiroyoshi; Fervaha, Gagan; Lee, Jimmy; Agid, Ofer; Remington, Gary

    2016-09-01

    Brief assessments have the potential to be widely adopted as outcome measures in research but also routine clinical practice. Existing brief rating scales that assess symptoms of schizophrenia or psychosis have a number of limitations including inability to capture five symptom domains of psychosis and a lack of clearly defined operational anchor points for scoring. We developed a new brief rating scale for five symptom domains of psychosis with clearly defined operational anchor points - the Brief Evaluation of Psychosis Symptom Domains (BE-PSD). To examine the psychometric properties of the BE-PSD, fifty patients with schizophrenia or schizoaffective disorder were included in this preliminary cross-sectional study. To test the convergent and discriminant validity of the BE-PSD, correlational analyses were employed using the consensus Positive and Negative Syndrome Scale (PANSS) five-factor model. To examine the inter-rater reliability of the BE-PSD, single measures intraclass correlation coefficients (ICCs) were calculated for 11 patients. The BE-PSD domain scores demonstrated high convergent validity with the corresponding PANSS factor score (rs = 0.81-0.93) as well as good discriminant validity, as evidenced by lower correlations with the other PANSS factors (rs = 0.23-0.62). The BE-PSD also demonstrated excellent inter-rater reliability for each of the domain scores and the total scores (ICC(2,1) = 0.79-0.96). The present preliminary study found the BE-PSD measure to be valid and reliable; however, further studies are needed to establish the psychometric properties of the BE-PSD because of the limitations such as the small sample size and lacking data on test-retest reliability or sensitivity to change. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Reliability Programs for Nonelectronic Designs. Volume 1

    DTIC Science & Technology

    1983-04-01

    to the system or component levels or to both and then Its degree of effectiveness. DOCUMENT ID TITLE/SUBJECT APPLICATION EFFECTIVENESS Sys ./Comp/Both...ID TITLE/SUBJECT APPLICATION EFFECTIVENESS ’ Sys ./Comp/Both Exc./Good/Poor MIL-STD-781B Reliability Tests Exponen- 1 1 1 1 Ii II tial Distribution MIL...DOCUMENT ID TITLE/SUBJECT APPLICATION EFFECTIVENESS Sys ./Comp/Both Exc./Good/Poor MIL-STD-1535A Supplier Quality Assurance I 1 I1 I 1 1 I Program

  13. Modern psychometrics for assessing achievement goal orientation: a Rasch analysis.

    PubMed

    Muis, Krista R; Winne, Philip H; Edwards, Ordene V

    2009-09-01

    A program of research is needed that assesses the psychometric properties of instruments designed to quantify students' achievement goal orientations to clarify inconsistencies across previous studies and to provide a stronger basis for future research. We conducted traditional psychometric and modern Rasch-model analyses of the Achievement Goals Questionnaire (AGQ, Elliot & McGregor, 2001) and the Patterns of Adaptive Learning Scale (PALS, Midgley et al., 2000) to provide an in-depth analysis of the two most popular instruments in educational psychology. For Study 1, 217 undergraduate students enrolled in educational psychology courses participated. Thirty-four were male and 181 were female (two did not respond). Participants completed the AGQ in the context of their educational psychology class. For Study 2, 126 undergraduate students enrolled in educational psychology courses participated. Thirty were male and 95 were female (one did not respond). Participants completed the PALS in the context of their educational psychology class. Traditional psychometric assessments of the AGQ and PALS replicated previous studies. For both, reliability estimates ranged from good to very good for raw subscale scores and fit for the models of goal orientations were good. Based on traditional psychometrics, the AGQ and PALS are valid and reliable indicators of achievement goals. Rasch analyses revealed that estimates of reliability for items were very good but respondent ability estimates varied from poor to good for both the AGQ and PALS. These findings indicate that items validly and reliably reflect a group's aggregate goal orientation, but using either instrument to characterize an individual's goal orientation is hazardous.

  14. COMFORT scale: a reliable and valid method to measure the amount of stress of ventilated preterm infants.

    PubMed

    Wielenga, J M; De Vos, R; de Leeuw, R; De Haan, R J

    2004-01-01

    Assessment of clinimetric properties and diagnostic quality of a stress measurement scale (COMFORT scale). Sample of an open population. Neonatology department (Neonatal Intensive Care Unit), Academic Medical Centre/Emma Children's Hospital, Amsterdam, The Netherlands. One clinical expert and 9 observers observed ventilated premature born babies simultaneously. Criterion validity was assessed by correlating the COMFORT scale with the clinical judgment regarding the amount of stress. Interobserver reliability was assessed on the clinical judgment as well as on the COMFORT scale. Diagnostic qualities were evaluated with a ROC curve. On 19 ventilated prematurely born babies (mean gestational age 30 weeks, mean birth weight 1385 gm), one clinical expert and 9 observers made 30 paired observations. The criterion validity of the COMFORT scale was good (Pearson's r of 0.84). The interobserver reliability of the clinical judgment was very good (weighted Kappa 0.84). The interobserver reliability of each item varied from good to almost perfect (weighted Kappa of 0.64 for muscle tone to 1.00 on heart rate). The reliability of the total COMFORT scale score was satisfying (intra-class correlation coefficient of 0.94). The diagnostic quality of the COMFORT scale was excellent, at a cut-off point of 20 the sensitivity was 100 percent, the specificity was 77 percent, and the area under the curve (AUC) of 0.95. In this first evaluation, the COMFORT scale appears to be a valid and reliable measurement tool to assess the stress of ventilated prematurely born babies.

  15. Validity and reliability of the Turkish Migraine Disability Assessment (MIDAS) questionnaire.

    PubMed

    Ertaş, Mustafa; Siva, Aksel; Dalkara, Turgay; Uzuner, Nevzat; Dora, Babür; Inan, Levent; Idiman, Fethi; Sarica, Yakup; Selçuki, Deniz; Sirin, Hadiye; Oğuzhanoğlu, Atilla; Irkeç, Ceyla; Ozmenoğlu, Mehmet; Ozbenli, Taner; Oztürk, Musa; Saip, Sabahattin; Neyal, Münife; Zarifoğlu, Mehmet

    2004-09-01

    The aim of this study is to assess the comprehensibility, internal consistency, patient-physician reliability, test-retest reliability, and validity of Turkish version of Migraine Disability Assessment (MIDAS) questionnaire in patients with headache. MIDAS questionnaire has been developed by Stewart et al and shown to be reliable and valid to determine the degree of disability caused by migraine. This study was designed as a national multicenter study to demonstrate the reliability and validity of Turkish version of MIDAS questionnaire. Patients applying to 17 Neurology Clinics in Turkey were evaluated at the baseline (visit 1), week 4 (visit 2), and week 12 (visit 3) visits in terms of disease severity and comprehensibility, internal consistency, test-retest reliability, and validity of MIDAS. Since the severity of the disease has been found to change significantly at visit 2 compared to visit 1, test-retest reliability was assessed using the MIDAS scores of a subgroup of patients whose disease severity remained unchanged (up to +/-3 days difference in the number of days with headache between visits 1 and 2). A total of 306 patients (86.2% female, mean age: 35.0 +/- 9.8 years) were enrolled into the study. A total of 65.7%, 77.5%, 82.0% of patients reported that "they had fully understood the MIDAS questionnaire" in visits 1, 2, and 3, respectively. A highly positive correlation was found between physician and patient and the applied total MIDAS scores in all three visits (Spearman correlation coefficients were R= 0.87, 0.83, and 0.90, respectively, P <.001). Internal consistency of MIDAS was assessed using Cronbach's alpha and was found at acceptable (>0.7) or excellent (>0.8) levels in both patient and physician applied MIDAS scores, respectively. Total MIDAS score showed good test-retest reliability (R= 0.68). Both the number of days with headache and the total MIDAS scores were positively correlated at all visits with correlation coefficients between 0.47 and 0.63. There was also a moderate degree of correlation (R= 0.54) between the total MIDAS score at week 12 and the number of days with headache at visit 2 + visit 3, which quantify headache-related disability over a 3-month period similar to MIDAS questionnaire. These findings demonstrated that the Turkish translation is equivalent to the English version of MIDAS in terms of internal consistency, test-retest reliability, and validity. Physicians can reliably use the Turkish translation of the MIDAS questionnaire in defining the severity of illness and its treatment strategy when applied as a self-administered report by migraine patients themselves.

  16. Reliability and Validity of the Korean Version of the Symptom Checklist-Post-Traumatic Stress Disorder Scale

    PubMed Central

    2016-01-01

    The Symptom Checklist - Post-Traumatic Stress Disorder Scale (SCL-PTSD), also known as Crime-Related PTSD Scale has been validated in survivors of interpersonal trauma in the general population. However, the psychometric properties have not been investigated in a clinical setting for patients with PTSD from diverse traumatic events. This study investigates the reliability and validity of the Korean version of the SCL-PTSD among 104 psychiatric outpatients with PTSD, caused by interpersonal (n = 50) or non-interpersonal trauma (n = 54). Self-report data of the SCL-PTSD, Beck Depression Inventory (BDI), State-Trait Anxiety Inventory (STAI), and Impact of Events Scale-Revised (IES-R) were gathered. The Korean version of the SCL-PTSD showed excellent internal consistency and moderate-to-good four-week temporal stability in both the interpersonal and non-interpersonal trauma groups. In comparison with other diagnostic groups, the scores of the SCL-PTSD were significantly higher compared to those of adjustment disorder, depression, other anxiety disorders, and schizophrenia, demonstrating its criteria-related validity. Convergent validity was confirmed because the scores of the SCL-PTSD were significantly correlated with BDI, SAI and TAI scores. Concurrent validity was demonstrated by significant correlation with the IES-R score. This study demonstrated the favorable psychometric prosperities of the Korean version of the SCL-PTSD, supporting its use in clinical research and practice. PMID:27134501

  17. [Reliability and validity of Driving Anger Scale in professional drivers in China].

    PubMed

    Li, Z; Yang, Y M; Zhang, C; Li, Y; Hu, J; Gao, L W; Zhou, Y X; Zhang, X J

    2017-11-10

    Objective: To assess the reliability and validity of the Chinese version of Driving Anger Scale (DAS) in professional drivers in China and provide a scientific basis for the application of the scale in drivers in China. Methods: Professional drivers, including taxi drivers, bus drivers, truck drivers and school bus drivers, were selected to complete the questionnaire. Cronbach's α and split-half reliability were calculated to evaluate the reliability of DAS, and content, contract, discriminant and convergent validity were performed to measure the validity of the scale. Results: The overall Cronbach's α of DAS was 0.934 and the split-half reliability was 0.874. The correlation coefficient of each subscale with the total scale was 0.639-0.922. The simplified version of DAS supported a presupposed six-factor structure, explaining 56.371% of the total variance revealed by exploratory factor analysis. The DAS had good convergent and discriminant validity, with the success rate of calibration experiment of 100%. Conclusion: DAS has a good reliability and validity in professional drivers in China, and the use of DAS is worth promoting in divers.

  18. Development and testing of an automated computer tablet-based method for self-testing of high and low contrast near visual acuity in ophthalmic patients.

    PubMed

    Aslam, Tariq M; Parry, Neil R A; Murray, Ian J; Salleh, Mahani; Col, Caterina Dal; Mirza, Naznin; Czanner, Gabriela; Tahir, Humza J

    2016-05-01

    Many eye diseases require on-going assessment for optimal management, creating an ever-increasing burden on patients and hospitals that could potentially be reduced through home vision monitoring. However, there is limited evidence for the utility of current applications and devices for this. To address this, we present a new automated, computer tablet-based method for self-testing near visual acuity (VA) for both high and low contrast targets. We report on its reliability and agreement with gold standard measures. The Mobile Assessment of Vision by intERactIve Computer (MAVERIC) system consists of a calibrated computer tablet housed in a bespoke viewing chamber. Purpose-built software automatically elicits touch-screen responses from subjects to measure their near VA for either low or high contrast acuity. Near high contrast acuity was measured using both the MAVERIC system and a near Landolt C chart in one eye for 81 patients and low contrast acuity using the MAVERIC system and a 25 % contrast near EDTRS chart in one eye of a separate 95 patients. The MAVERIC near acuity was also retested after 20 min to evaluate repeatability. Repeatability of both high and low contrast MAVERIC acuity measures, and their agreement with the chart tests, was assessed using the Bland-Altman comparison method. One hundred and seventy-three patients (96 %) completed the self- testing MAVERIC system without formal assistance. The resulting MAVERIC vision demonstrated good repeatability and good agreement with the gold-standard near chart measures. This study demonstrates the potential utility of the MAVERIC system for patients with ophthalmic disease to self-test their high and low contrast VA. The technique has a high degree of reliability and agreement with gold standard chart based measurements.

  19. Evaluation of Psychometric Properties of Voice Activity and Participation Profile (VAPP): A Spanish Version.

    PubMed

    Bermúdez-de-Alvear, Rosa M; Gálvez-Ruiz, Pablo; Martínez-Arquero, A Ginés; Rando-Márquez, Sara; Fernández-Contreras, Elena

    2018-06-11

    This study aimed to analyze the psychometric properties of the Spanish version of the Voice Activity and Participation Profile (SVAPP) questionnaire. A randomized, cross-sectional sampling strategy with controls was used. Two samples with a total of 169 participants were analyzed, specifically 61 men (mean age 37.02) and 108 women (mean age 37.78). Of these participants, 112 were patients and 57 were controls. The instrument was submitted to reliability (internal consistency and corrected item-total correlations) and reproducibility analyses. Validation assessment was based on the construct validity, convergent validity, discriminant validity, and concurrent validity. The global internal consistency was excellent (Cronbach's α = 0.976), corrected item-total correlations were satisfactory and ranged 0.63-0.89, and factor loadings were above 0.50. The different subscales showed good internal consistency (alpha coefficients ranged 0.830-0.956) and test-retest values were consistently associated. The exploratory factor analysis evidenced a strongly defined five factors internal structure, with factors loadings ranging 0.51-0.86. Convergent validity demonstrated that all subscales and scores were very strongly correlated (Pearson r above 0.735) and significantly associated. The discriminant validity analysis showed that SVAPP had good specificity to distinguish dysphonic from healthy voice subjects. Concurrent validity with Voice Handicap Index Spanish version (SVHI) showed very strong correlations between total scores, and between SVHI total score and SVAPP Daily and Social Communication subscales; correlations between both tests subscales were strong; only between SVAPP Work and SVHI Physical sections correlations were moderate. The findings of the present study demonstrated evidence for the SVAPP questionnaire reliability and validity, and provided insightful implications of voice disorders on Spanish patients' quality of life. However, further investigations are required. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  20. Validation of the FASH (Functional Assessment Scale for Acute Hamstring Injuries) questionnaire for German-speaking football players.

    PubMed

    Lohrer, Heinz; Nauck, Tanja; Korakakis, Vasileios; Malliaropoulos, Nikos

    2016-10-24

    The FASH (Functional Assessment Scale for Acute Hamstring Injuries) questionnaire has been recently developed as a disease-specific self-administered questionnaire for use in Greek, English, and German languages. Its psychometric qualities (validity and reliability) were tested only in Greek-speaking patients mainly representing track and field athletes. As hamstring injuries represent the most common football injury, we tested the validity and reliability of the FASH-G (G = German version) questionnaire in German-speaking footballers suffering from acute hamstring injuries. The FASH-G questionnaire was tested for reliability and validity, in 16 footballers with hamstring injuries (patients' group), 77 asymptomatic footballers (healthy group), and 19 field hockey players (at-risk group). Known-group validity was tested by comparing the total FASH-G scores of the injured and non-injured groups. Reliability of the FASH-G questionnaire was analysed in 18 asymptomatic footballers using the intra-class coefficient. Known-group validity was demonstrated by significant differences between injured and non-injured participants (p < 0.001). The FASH-G exhibited very good test-retest reliability (intra-class correlation coefficient = 0.982, p < 0.001). Internal consistency was excellent (α = 0.938). Compared with the results presented in the original publication, no statistical differences were found between healthy athletes (p = 0.257), but patients' groups and at-risk groups presented scoring differences (p = 0.040 and <0.001, respectively). The FASH-G is a valid and reliable instrument to assess and determine the severity of hamstring injuries in German footballers.

  1. A New Volumetric Radiologic Method to Assess Indirect Decompression After Extreme Lateral Interbody Fusion Using High-Resolution Intraoperative Computed Tomography.

    PubMed

    Navarro-Ramirez, Rodrigo; Berlin, Connor; Lang, Gernot; Hussain, Ibrahim; Janssen, Insa; Sloan, Stephen; Askin, Gulce; Avila, Mauricio J; Zubkov, Micaella; Härtl, Roger

    2018-01-01

    Two-dimensional radiographic methods have been proposed to evaluate the radiographic outcome after indirect decompression through extreme lateral interbody fusion (XLIF). However, the assessment of neural decompression in a single plane may underestimate the effect of indirect decompression on central canal and foraminal volumes. The present study aimed to assess the reliability and consistency of a novel 3-dimensional radiographic method that assesses neural decompression by volumetric analysis using a new generation of intraoperative fan-beam computed tomography scanner in patients undergoing XLIF. Prospectively collected data from 7 patients (9 levels) undergoing XLIF was retrospectively analyzed. Three independent, blind raters using imaging analysis software performed volumetric measurements pre- and postoperatively to determine central canal and foraminal volumes. Intrarater and Interrater reliability tests were performed to assess the reliability of this novel volumetric method. The interrater reliability between the three raters ranged from 0.800 to 0.952, P < 0.0001. The test-retest analysis on a randomly selected subset of three patients showed good to excellent internal reliability (range of 0.78-1.00) for all 3 raters. There was a significant increase in mean volume ≈20% for right foramen, left foramen, and central canal volumes postoperatively (P = 0.0472; P = 0.0066; P = 0.0003, respectively). Here we demonstrate a new volumetric analysis technique that is feasible, reliable, and reproducible amongst independent raters for central canal and foraminal volumes in the lumbar spine using an intraoperative computed tomography scanner. Copyright © 2017. Published by Elsevier Inc.

  2. Using Rasch Analysis to Evaluate the Reliability and Validity of the Swallowing Quality of Life Questionnaire: An Item Response Theory Approach.

    PubMed

    Cordier, Reinie; Speyer, Renée; Schindler, Antonio; Michou, Emilia; Heijnen, Bas Joris; Baijens, Laura; Karaduman, Ayşe; Swan, Katina; Clavé, Pere; Joosten, Annette Veronica

    2018-02-01

    The Swallowing Quality of Life questionnaire (SWAL-QOL) is widely used clinically and in research to evaluate quality of life related to swallowing difficulties. It has been described as a valid and reliable tool, but was developed and tested using classic test theory. This study describes the reliability and validity of the SWAL-QOL using item response theory (IRT; Rasch analysis). SWAL-QOL data were gathered from 507 participants at risk of oropharyngeal dysphagia (OD) across four European countries. OD was confirmed in 75.7% of participants via videofluoroscopy and/or fiberoptic endoscopic evaluation, or a clinical diagnosis based on meeting selected criteria. Patients with esophageal dysphagia were excluded. Data were analysed using Rasch analysis. Item and person reliability was good for all the items combined. However, person reliability was poor for 8 subscales and item reliability was poor for one subscale. Eight subscales exhibited poor person separation and two exhibited poor item separation. Overall item and person fit statistics were acceptable. However, at an individual item fit level results indicated unpredictable item responses for 28 items, and item redundancy for 10 items. The item-person dimensionality map confirmed these findings. Results from the overall Rasch model fit and Principal Component Analysis were suggestive of a second dimension. For all the items combined, none of the item categories were 'category', 'threshold' or 'step' disordered; however, all subscales demonstrated category disordered functioning. Findings suggest an urgent need to further investigate the underlying structure of the SWAL-QOL and its psychometric characteristics using IRT.

  3. [Reliability and validity of depression scales of Chinese version: a systematic review].

    PubMed

    Sun, X Y; Li, Y X; Yu, C Q; Li, L M

    2017-01-10

    Objective: Through systematically reviewing the reliability and validity of depression scales of Chinese version in adults in China to evaluate the psychometric properties of depression scales for different groups. Methods: Eligible studies published before 6 May 2016 were retrieved from the following database: CNKI, Wanfang, PubMed and Embase. The HSROC model of the diagnostic test accuracy (DTA) for Meta-analysis was used to calculate the pooled sensitivity and specificity of the PHQ-9. Results: A total of 44 papers evaluating the performance of depression scales were included. Results showed that the reliability and validity of the common depression scales were eligible, including the Beck depression inventory (BDI), the Hamilton depression scale (HAMD), the center epidemiological studies depression scale (CES-D), the patient health questionnaire (PHQ) and the Geriatric depression scale (GDS). The Cronbach' s coefficient of most tools were larger than 0.8, while the test-retest reliability and split-half reliability were larger than 0.7, indicating good internal consistency and stability. The criterion validity, convergent validity, discrimination validity and screening validity were acceptable though different cut-off points were recommended by different studies. The pooled sensitivity of the 11 studies evaluating PHQ-9 was 0.88 (95 %CI : 0.85-0.91) while the pooled specificity was 0.89 (95 %CI : 0.82-0.94), which demonstrated the applicability of PHQ-9 in screening depression. Conclusion: The reliability and validity of different depression scales of Chinese version are acceptable. The characteristics of different tools and study population should be taken into consideration when choosing a specific scale.

  4. [Evaluation of Suicide Risk Levels in Hospitals: Validity and Reliability Tests].

    PubMed

    Macagnino, Sandro; Steinert, Tilman; Uhlmann, Carmen

    2018-05-01

    Examination of in-hospital suicide risk levels concerning their validity and their reliability. The internal suicide risk levels were evaluated in a cross sectional study of in 163 inpatients. A reliability check was performed via determining interrater-reliability of senior physician, therapist and the responsible nurse. Within the scope of the validity check, we conducted analyses of criterion validity and construct validity. For the total sample an "acceptable" to "good" interrater-reliability (Kendalls W = .77) of suicide risk levels were obtained. Schizophrenic disorders showed the lowest values, for personality disorders we found the highest level of interrater-reliability. When examining the criterion validity, Item-9 of the BDI-II is substantial correlated to our suicide risk levels (ρ m  = .54, p < .01). Within the scope of construct validity check, affective disorders showed the highest correlation (ρ = .77), compatible also with "convergent validity". They differed with schizophrenic disorders which showed the least concordance (ρ = .43). In-hospital suicide risk levels may represent an important contribution to the assessment of suicidal behavior of inpatients experiencing psychiatric treatment due to their overall good validity and reliability. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Inter-observer and intra-observer reliability in the radiographic diagnosis of avascular necrosis of the femoral head following reconstructive hip surgery in children with cerebral palsy.

    PubMed

    Hesketh, Kim; Sankar, Wudbhav; Joseph, Benjamin; Narayanan, Unni; Mulpuri, Kishore

    2016-04-01

    The incidence of avascular necrosis (AVN) following reconstructive hip surgery in cerebral palsy (CP) ranges from 0 to 69 % in the current literature. The purpose of this study was to determine the inter- and intra-observer reliability of radiographically diagnosing AVN in children with CP after hip surgery. A retrospective review of 65 children with CP who had reconstructive hip surgery between 2009 and 2012 at BC Children's Hospital was completed. Anterior-posterior and lateral radiographs were presented to four pediatric orthopaedic surgeons over two rounds. Surgeons were asked to review the set of unidentified radiographs and comment 'yes' or 'no' for the presence of AVN. Two weeks later the same set of radiographs was sent in a different order and the surgeons were again asked to comment on AVN. Inter- and intra-observer reliability was determined using kappa statistics. The intra-observer reliability ranged from 0.65 to 0.88 with an average score of 0.76. Inter-observer reliability showed greater variability, ranging from 0.41 to 0.77 with an average score of 0.56 across all surgeons. Although the intra-rater reliability produced a strength of "good" and the inter-rater reliability a strength of "moderate" agreement, the variability within these scores is clinically important as it demonstrates the difficulty in identifying AVN. This may explain the variability in AVN that is reported in the literature. The need for further education and research in the diagnosis of AVN in children with CP who have undergone reconstructive hip surgery is clinically necessary.

  6. Development and validation of the Myasthenia Gravis Impairment Index.

    PubMed

    Barnett, Carolina; Bril, Vera; Kapral, Moira; Kulkarni, Abhaya; Davis, Aileen M

    2016-08-30

    We aimed to develop a measure of myasthenia gravis impairment using a previously developed framework and to evaluate reliability and validity, specifically face, content, and construct validity. The first draft of the Myasthenia Gravis Impairment Index (MGII) included examination items from available measures enriched with newly developed, patient-reported items, modified after patient input. International neuromuscular specialists evaluated face and content validity via an e-mail survey. Test-retest reliability was assessed in stable patients at a 3-week interval and interrater reliability was evaluated in the same day. Construct validity was assessed through correlations between the MGII and other measures and by comparing scores in different patient groups. The first draft was assessed by 18 patients, and 72 specialists answered the survey. The second draft had 7 examination and 22 patient-reported items. Field testing included 200 patients, with 54 patients completing the reliability studies. Test-retest reliability of the total score was good (intraclass correlation coefficient 0.92; 95% confidence interval 0.79-0.94), as was interrater reliability of the examination component (intraclass correlation coefficient 0.81; 95% confidence interval 0.79-0.94). The MGII correlated well with comparison measures, with higher correlations with the MG-activities of daily living (r = 0.91) and MG-specific quality of life 15-item scale (r = 0.78). When assessing different patient groups, the scores followed expected patterns. The MGII was developed using a patient-centered framework of myasthenia-related impairments and incorporating patient input throughout the development process. It is reliable in an outpatient setting and has demonstrated construct validity. Responsiveness studies are under way. © 2016 American Academy of Neurology.

  7. Development and validation of the Myasthenia Gravis Impairment Index

    PubMed Central

    Bril, Vera; Kapral, Moira; Kulkarni, Abhaya; Davis, Aileen M.

    2016-01-01

    Objective: We aimed to develop a measure of myasthenia gravis impairment using a previously developed framework and to evaluate reliability and validity, specifically face, content, and construct validity. Methods: The first draft of the Myasthenia Gravis Impairment Index (MGII) included examination items from available measures enriched with newly developed, patient-reported items, modified after patient input. International neuromuscular specialists evaluated face and content validity via an e-mail survey. Test–retest reliability was assessed in stable patients at a 3-week interval and interrater reliability was evaluated in the same day. Construct validity was assessed through correlations between the MGII and other measures and by comparing scores in different patient groups. Results: The first draft was assessed by 18 patients, and 72 specialists answered the survey. The second draft had 7 examination and 22 patient-reported items. Field testing included 200 patients, with 54 patients completing the reliability studies. Test–retest reliability of the total score was good (intraclass correlation coefficient 0.92; 95% confidence interval 0.79–0.94), as was interrater reliability of the examination component (intraclass correlation coefficient 0.81; 95% confidence interval 0.79–0.94). The MGII correlated well with comparison measures, with higher correlations with the MG–activities of daily living (r = 0.91) and MG-specific quality of life 15-item scale (r = 0.78). When assessing different patient groups, the scores followed expected patterns. Conclusions: The MGII was developed using a patient-centered framework of myasthenia-related impairments and incorporating patient input throughout the development process. It is reliable in an outpatient setting and has demonstrated construct validity. Responsiveness studies are under way. PMID:27402891

  8. Phases of match-play in professional Australian Football: Descriptive analysis and reliability assessment.

    PubMed

    Rennie, Michael J; Watsford, Mark L; Spurrs, Robert W; Kelly, Stephen J; Pine, Matthew J

    2018-06-01

    To examine the frequency and time spent in the phases of Australian Football (AF) match-play and to assess the intra-assessor reliability of coding these phases of match-play. Observational, intra-reliability assessment. Video footage of 10 random quarters of AF match-play were coded by a single researcher. Phases of offence, defence, contested play, umpire stoppage, set shot and goal reset were coded using a set of operational definitions. Descriptive statistics were provided for all phases of match-play. Following a 6-month washout period, intra-coder reliability was assessed using typical error of measurement (TEM) and intra-class correlation coefficients (ICC). A quarter of AF match-play involved 128±20 different phases of match-play. The highest proportion of match-play involved contested play (25%), followed by offence (18%), defence (18%) and umpire stoppages (18%). The mean duration of offence, defence, contested play, umpire stoppage, set shot and goal reset were 14, 14, 10, 11, 28 and 47s, respectively. No differences were found between the two coding assessments (p>0.05). ICCs for coding the phases of play demonstrated very high reliability (r=0.902-0.992). TEM of the total time spent in each phase of play represented moderate to good reliability (TEM=1.8-9.3%). Coding of offence, defence and contested play tended to display slightly poorer TEMs than umpire stoppages, set shots and goal resets (TEM=8.1 vs 4.5%). Researchers can reliably code the phases of AF match-play which may permit the analysis of specific elements of competition. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Gait Deviation Index, Gait Profile Score and Gait Variable Score in children with spastic cerebral palsy: Intra-rater reliability and agreement across two repeated sessions.

    PubMed

    Rasmussen, Helle Mätzke; Nielsen, Dennis Brandborg; Pedersen, Niels Wisbech; Overgaard, Søren; Holsgaard-Larsen, Anders

    2015-07-01

    The Gait Deviation Index (GDI) and Gait Profile Score (GPS) are the most used summary measures of gait in children with cerebral palsy (CP). However, the reliability and agreement of these indices have not been investigated, limiting their clinimetric quality for research and clinical practice. The aim of this study was to investigate the intra-rater reliability and agreement of summary measures of gait (GDI; GPS; and the Gait Variable Score (GVS) derived from the GPS). The intra-rater reliability and agreement were investigated across two repeated sessions in 18 children aged 5-12 years diagnosed with spastic CP. No systematic bias was observed between the sessions and no heteroscedasticity was observed in Bland-Altman plots. For the GDI and GPS, excellent reliability with intraclass correlation coefficient (ICC) values of 0.8-0.9 was found, while the GVS was found to have fair to good reliability with ICCs of 0.4-0.7. The agreement for the GDI and the logarithmically transformed GPS, in terms of the standard error of measurement as a percentage of the grand mean (SEM%) varied from 4.1 to 6.7%, whilst the smallest detectable change in percent (SDC%) ranged from 11.3 to 18.5%. For the logarithmically transformed GVS, we found a fair to large variation in SEM% from 7 to 29% and in SDC% from 18 to 81%. The GDI and GPS demonstrated excellent reliability and acceptable agreement proving that they can both be used in research and clinical practice. However, the observed large variability for some of the GVS requires cautious consideration when selecting outcome measures. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Reliability of dynamometric passive properties of the pelvic floor muscles in postmenopausal women with stress urinary incontinence.

    PubMed

    Morin, Mélanie; Gravel, Denis; Bourbonnais, Daniel; Dumoulin, Chantale; Ouellet, Stéphane

    2008-01-01

    The passive properties of the pelvic floor muscles (PFM) might play a role in stress urinary incontinence (SUI) pathophysiology. To investigate the test-retest reliability of the dynamometric passive properties of the PFM in postmenopausal SUI women. Thirty-two SUI postmenopausal women were convened to two sessions 2 weeks apart. In each session, the measurements were repeated twice. The pelvic floor musculature was evaluated in four different conditions: (1) forces recorded at minimal aperture (initial passive resistance); (2) passive resistance at maximal aperture; (3) five lengthening and shortening cycles (Forces and passive elastic stiffness (PES) were evaluated at different vaginal apertures. Hysteresis was also calculated.); (4) Percentage of passive resistance loss after 1 min of sustained stretching was computed. The generalizability theory was used to calculate two reliability estimates, the dependability indices (Phi) and the standard error of measurement (SEM), for one session involving one measurement or the mean of two measurements. Overall, the reliability of the passive properties was good with indices of dependability of 0.75-0.93. The SEMs for forces and PES were 0.24-0.67 N and 0.03-0.10 N/mm, respectively, for mean, maximal and 20-mm apertures, representing an error between 13% and 23%. Passive forces at minimal aperture showed lower reliability (Phi = 0.51-0.57) compared with other vaginal openings. The aperture at a common force of 0.5 N was the only parameter demonstrating a poor reliability (Phi = 0.35). This new approach for assessing PFM passive properties showed enough reliability for highly recommending its inclusion in the PFM assessment of SUI postmenopausal women. (c) 2008 Wiley-Liss, Inc.

  11. The multiple sclerosis work difficulties questionnaire: translation and cross-cultural adaptation to Turkish and assessment of validity and reliability.

    PubMed

    Kahraman, Turhan; Özdoğar, Asiye Tuba; Honan, Cynthia Alison; Ertekin, Özge; Özakbaş, Serkan

    2018-05-09

    To linguistically and culturally adapt the Multiple Sclerosis Work Difficulties Questionnaire-23 (MSWDQ-23) for use in Turkey, and to examine its reliability and validity. Following standard forward-back translation of the MSWDQ-23, it was administered to 124 people with multiple sclerosis (MS). Validity was evaluated using related outcome measures including those related to employment status and expectations, disability level, fatigue, walking, and quality of life. Randomly selected participants were asked to complete the MSWDQ-23 again to assess test-retest reliability. Confirmatory factor analysis on the MSWDQ-23 demonstrated a good fit for the data, and the internal consistency of each subscale was excellent. The test-retest reliability for the total score, psychological/cognitive barriers, physical barriers, and external barriers subscales were high. The MSWDQ-23 and its subscales were positively correlated with the employment, disability level, walking, and fatigue outcome measures. This study suggests that the Turkish version of MSWDQ-23 has high reliability and adequate validity, and it can be used to determine the difficulties faced by people with multiple sclerosis in workplace. Moreover, the study provides evidence about the test-retest reliability of the questionnaire. Implications for rehabilitation Multiple sclerosis affects young people of working age. Understanding work-related problems is crucial to enhance people with multiple sclerosis likelihood of maintaining their job. The Multiple Sclerosis Work Difficulties Questionnaire-23 (MSWDQ-23) is a valid and reliable measure of perceived workplace difficulties in people with multiple sclerosis: we presented its validation to Turkish. Professionals working in the field of vocational rehabilitation may benefit from using the MSWDQ-23 to predict the current work outcomes and future employment expectations.

  12. Development of the Chinese version of the Hospital Autonomy Questionnaire: a cross-sectional study in Guangdong Province

    PubMed Central

    Liu, Zifeng; Yuan, Lianxiong; Huang, Yixiang; Zhang, Lingling; Luo, Futian

    2016-01-01

    Objective We aimed to develop a questionnaire for quantitative evaluation of the autonomy of public hospitals in China. Method An extensive literature review was conducted to select possible items for inclusion in the questionnaire, which was then reviewed by 5 experts. After a two-round Delphi method, we distributed the questionnaire to 404 secondary and tertiary hospitals in Guangdong Province, China, and 379 completed questionnaires were collected. The final questionnaire was then developed on the basis of the results of exploratory and confirmatory factor analysis. Results Analysis suggested that all internal consistency reliabilities exceeded the minimum reliability standard of 0.70 for the α coefficient. The overall scale coefficient was 0.87, and 6 subscale coefficients were 0.92 (strategic management), 0.81 (budget and expenditure), 0.85 (financing), 0.75 (financing, medical management), 0.86 (human resources) and 0.86 (accountability). Correlation coefficients between and among items and their hypothesised subscales were higher than those with other subscales. The value of average variance extracted (AVE) was higher than 0.5, the value of construct reliability (CR) was higher than 0.7, and the square roots of the AVE of each subscale were larger than the correlation of the specific subscale with the other subscales, supporting the convergent and discriminant validity of the Chinese version of the Hospital Autonomy Questionnaire (CVHAQ). The model fit indices were all acceptable: χ2/df=1.73, Goodness of Fit Index (GFI) = 0.93, Adjusted Goodness of Fit Index (AGFI) = 0.91, Non-Normed Fit Index (NNFI) = 0.96, Comparative Fit Index (CFI) = 0.97, Root Mean Square Error of Approximation (RMSEA) = 0.04, Standardised Root Mean Square Residual (SRMR) = 0.07. Conclusions This study demonstrated the reliability and validity of a CVHAQ and provides a quantitative method for the assessment of hospital autonomy. PMID:26911587

  13. Assessing Ethics Knowledge: Development of a Test of Ethics Knowledge in Neonatology.

    PubMed

    Cummings, Christy L; Geis, Gina M; Feldman, Henry A; Berson, Elisa R; Kesselheim, Jennifer C

    2018-05-10

    To develop and validate the Test of Ethics Knowledge in Neonatology (TEK-Neo) with good internal consistency reliability, item performance, and construct validity that reliably assesses interprofessional staff and trainee knowledge of neonatal ethics. We adapted a published test of ethics knowledge for use in neonatology. The novel instrument had 46 true/false questions distributed among 7 domains of neonatal ethics: ethical principles, professionalism, genetic testing, beginning of life/viability, end of life, informed permission/decision making, and research ethics. Content and correct answers were derived from published statements and guidelines. We administered the voluntary, anonymous test via e-mailed link to 103 participants, including medical students, neonatology fellows, neonatologists, neonatology nurses, and pediatric ethicists. After item reduction, we examined psychometric properties of the resulting 36-item test and assessed overall sample performance. The overall response rate was 27% (103 of 380). The test demonstrated good internal reliability (Cronbach α = 0.66), with a mean score of 28.5 ± 3.4 out of the maximum 36. Participants with formal ethics training performed better than those without (30.3 ± 2.9 vs 28.1 ± 3.5; P = .01). Performance improved significantly with higher levels of medical/ethical training among the 5 groups: medical students, 25.9 ± 3.7; neonatal nurses/practitioners, 27.7 ± 2.7; neonatologists, 28.8 ± 3.7; neonatology fellows, 29.8 ± 2.9; and clinical ethicists, 33.0 ± 1.9 (P < .0001). The TEK-Neo reliably assesses knowledge of neonatal ethics among interprofessional staff and trainees in neonatology. This novel tool discriminates between learners with different levels of expertise and can be used interprofessionally to assess individual and group performance, track milestone progression, and address curricular gaps in neonatal ethics. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Evaluating trauma team performance in a Level I trauma center: Validation of the trauma team communication assessment (TTCA-24).

    PubMed

    DeMoor, Stephanie; Abdel-Rehim, Shady; Olmsted, Richard; Myers, John G; Parker-Raley, Jessica

    2017-07-01

    Nontechnical skills (NTS), such as team communication, are well-recognized determinants of trauma team performance and good patient care. Measuring these competencies during trauma resuscitations is essential, yet few valid and reliable tools are available. We aimed to demonstrate that the Trauma Team Communication Assessment (TTCA-24) is a valid and reliable instrument that measures communication effectiveness during activations. Two tools with adequate psychometric strength (Trauma Nontechnical Skills Scale [T-NOTECHS], Team Emergency Assessment Measure [TEAM]) were identified during a systematic review of medical literature and compared with TTCA-24. Three coders used each tool to evaluate 35 stable and 35 unstable patient activations (defined according to Advanced Trauma Life Support criteria). Interrater reliability was calculated between coders using the intraclass correlation coefficient. Spearman rank correlation coefficient was used to establish concurrent validity between TTCA-24 and the other two validated tools. Coders achieved an intraclass correlation coefficient of 0.87 for stable patient activations and 0.78 for unstable activations scoring excellent on the interrater agreement guidelines. The median score for each assessment showed good team communication for all 70 videos (TEAM, 39.8 of 54; T-NOTECHS, 17.4 of 25; and TTCA-24, 87.4 of 96). A significant correlation between TTTC-24 and T-NOTECHS was revealed (p = 0.029), but no significant correlation between TTCA-24 and TEAM (p = 0.77). Team communication was rated slightly better across all assessments for stable versus unstable patient activations, but not statistically significant. TTCA-24 correlated with T-NOTECHS, an instrument measuring nontechnical skills for trauma teams, but not TEAM, a tool that assesses communication in generic emergency settings. TTCA-24 is a reliable and valid assessment that can be a useful adjunct when evaluating interpersonal and team communication during trauma activations. Diagnostic tests or criteria, level II.

  15. Psychometric Validation of the Traditional Chinese Version of the Early Onset Scoliosis-24 Item Questionnaire (EOSQ-24).

    PubMed

    Cheung, Jason Pui Yin; Cheung, Prudence Wing Hang; Wong, Carlos King Ho; Samartzis, Dino; Luk, Keith Dip-Kei; Lam, Cindy Lo Kuen; Cheung, Kenneth Man Chee

    2016-12-15

    Questionnaire translation and validation. The aim of this study was to translate and cross-culturally adapt the Early Onset Scoliosis-24 item Questionnaire (EOSQ-24) into traditional Chinese, and to assess its validity, reliability, and sensitivity in Southern-Chinese patients diagnosed with early onset scoliosis (EOS). Relying on radiographs alone for assessing treatment outcomes in EOS patients is inadequate. To properly gauge health-related quality of life, a disease-specific instrument that assesses patient quality of life and the burden of primary caregivers is necessary. The EOSQ-24 was created for this purpose, but it has not been adapted to the Chinese language. The translation and cross-cultural adaptation of the original English EOSQ-24 were performed using the method of double forward and single backward translations, followed by a panel review. EOS patients of Southern-Chinese descent were recruited, via convenience sampling from a scoliosis specialty clinic. These patients' parents/caretakers were then administered the traditional Chinese EOSQ-24, Likert Scale regarding the understanding of completed EOSQ-24, and the Child Health Questionnaire Parent Form 50 (CHQ-PF50) (Traditional Chinese). Reliability was analyzed using Cronbach alpha. Construct validity of domains and subdomains was assessed using Spearman correlation test against CHQ-PF50 domains with similar constructs. Sensitivity of the EOSQ-24 scores was determined by performing known group comparisons. A total of 100 EOS patients were recruited. A very good reliability was demonstrated (Cronbach α: 0.896) and internal consistency of all domains was excellent (Cronbach α: 0.829-0.919). Subdomain scores of EOSQ-24 and CHQ-PF50 had significant correlations (P < 0.001), indicating a good construct validity. This is the first psychometric study to translate and adapt the EOSQ-24 questionnaire for Chinese EOS patients and it has been found to have satisfactory validity, reliability, and sensitivity. It is a useful disease-specific instrument for assessing patients' quality of life and the burden of caregivers. 2.

  16. Development and Validation of a Questionnaire to Detect Behavior Change in Multiple Advance Care Planning Behaviors

    PubMed Central

    Sudore, Rebecca L.; Stewart, Anita L.; Knight, Sara J.; McMahan, Ryan D.; Feuz, Mariko; Miao, Yinghui; Barnes, Deborah E.

    2013-01-01

    Introduction Advance directives have traditionally been considered the gold standard for advance care planning. However, recent evidence suggests that advance care planning involves a series of multiple discrete behaviors for which people are in varying stages of behavior change. The goal of our study was to develop and validate a survey to measure the full advance care planning process. Methods The Advance Care Planning Engagement Survey assesses “Process Measures” of factors known from Behavior Change Theory to affect behavior (knowledge, contemplation, self-efficacy, and readiness, using 5-point Likert scales) and “Action Measures” (yes/no) of multiple behaviors related to surrogate decision makers, values and quality of life, flexibility for surrogate decision making, and informed decision making. We administered surveys at baseline and 1 week later to 50 diverse, older adults from San Francisco hospitals. Internal consistency reliability of Process Measures was assessed using Cronbach's alpha (only continuous variables) and test-retest reliability of Process and Action Measures was examined using intraclass correlations. For discriminant validity, we compared Process and Action Measure scores between this cohort and 20 healthy college students (mean age 23.2 years, SD 2.7). Results Mean age was 69.3 (SD 10.5) and 42% were non-White. The survey took a mean of 21.4 minutes (±6.2) to administer. The survey had good internal consistency (Process Measures Cronbach's alpha, 0.94) and test-retest reliability (Process Measures intraclass correlation, 0.70; Action Measures, 0.87). Both Process and Action Measure scores were higher in the older than younger group, p<.001. Conclusion A new Advance Care Planning Engagement Survey that measures behavior change (knowledge, contemplation, self-efficacy, and readiness) and multiple advance care planning actions demonstrates good reliability and validity. Further research is needed to assess whether survey scores improve in response to advance care planning interventions and whether scores are associated with receipt of care consistent with one's wishes. PMID:24039772

  17. Validation of the German revised version of the program in palliative care education and practice questionnaire (PCEP-GR).

    PubMed

    Fetz, Katharina; Wenzel-Meyburg, Ursula; Schulz-Quach, Christian

    2017-12-28

    The evaluation of the effectiveness of undergraduate palliative care education (UPCE) programs is an essential foundation to providing high-quality UPCE programs. Therefore, the implementation of valid evaluation tools is indispensable. Until today, there has been no general consensus regarding concrete outcome parameters and their accurate measurement. The Program in Palliative Care Education and Practice Questionnaire (German Revised Version; PCEP-GR) is a promising assessment tool for UPCE. The aim of the current study was to evaluate the psychometric properties of PCEP-GR and to demonstrate its feasibility for the evaluation of UPCE programs. The practical feasibility of the PCEP-GR and its acceptance in medical students were investigated in a pilot study with 24 undergraduate medical students at Heinrich Heine University Dusseldorf, Germany. Subsequently, the PCEP-GR was surveyed in a representative sample (N = 680) of medical students in order to investigate its psychometric properties. Factorial validity was investigated by means of principal component analysis (PCA). Reliability was examined by means of split-half-reliability analysis and analysis of internal consistency. After taking into consideration the PCA and distribution analysis results, an evaluation instruction for the PCEP-GR was developed. The PCEP-GR proved to be feasible and well-accepted in medical students. PCA revealed a four-factorial solution indicating four PCEP-GR subscales: preparation to provide palliative care, attitudes towards palliative care, self-estimation of competence in communication with dying patients and their relatives and self-estimation of knowledge and skills in palliative care. The PCEP-GR showed good split-half-reliability and acceptable to good internal consistency of subscales. Attitudes towards palliative care slightly missed the criterion of acceptable internal consistency. The evaluation instruction suggests a global PCEP-GR index and four subscales. The PCEP-GR has proven to be a feasible, economic, valid and reliable tool for the assessment of UPCE that comprises self-efficacy expectation and relevant attitudes towards palliative care.

  18. "Up Means Good": The Effect of Screen Position on Evaluative Ratings in Web Surveys.

    PubMed

    Tourangeau, Roger; Couper, Mick P; Conrad, Frederick G

    2013-01-01

    This paper presents results from six experiments that examine the effect of the position of an item on the screen on the evaluative ratings it receives. The experiments are based on the idea that respondents expect "good" things-those they view positively-to be higher up on the screen than "bad" things. The experiments use items on different topics (Congress and HMOs, a variety of foods, and six physician specialties) and different methods for varying their vertical position on the screen. A meta-analysis of all six experiments demonstrates a small but reliable effect of the item's screen position on mean ratings of the item; the ratings are significantly more positive when the item appears in a higher position on the screen than when it appears farther down. These results are consistent with the hypothesis that respondents follow the "Up means good" heuristic, using the vertical position of the item as a cue in evaluating it. Respondents seem to rely on heuristics both in interpreting response scales and in forming judgments.

  19. Good practices in free-energy calculations.

    PubMed

    Pohorille, Andrew; Jarzynski, Christopher; Chipot, Christophe

    2010-08-19

    As access to computational resources continues to increase, free-energy calculations have emerged as a powerful tool that can play a predictive role in a wide range of research areas. Yet, the reliability of these calculations can often be improved significantly if a number of precepts, or good practices, are followed. Although the theory upon which these good practices rely has largely been known for many years, it is often overlooked or simply ignored. In other cases, the theoretical developments are too recent for their potential to be fully grasped and merged into popular platforms for the computation of free-energy differences. In this contribution, the current best practices for carrying out free-energy calculations using free energy perturbation and nonequilibrium work methods are discussed, demonstrating that at little to no additional cost, free-energy estimates could be markedly improved and bounded by meaningful error estimates. Monitoring the probability distributions that underlie the transformation between the states of interest, performing the calculation bidirectionally, stratifying the reaction pathway, and choosing the most appropriate paradigms and algorithms for transforming between states offer significant gains in both accuracy and precision.

  20. Translation, Cross-cultural Adaptation and Validation of the Farsi Version of NIH Task Force's Recommended Multidimensional Minimal Dataset for Research on Chronic Low Back Pain.

    PubMed

    Noormohammadpour, Pardis; Tavana, Bahareh; Mansournia, Mohammad Ali; Zeinalizadeh, Mehdi; Mirzashahi, Babak; Rostami, Mohsen; Kordi, Ramin

    2018-05-01

    Translation and cultural adaptation of the National Institutes of Health (NIH) Task Force's minimal dataset. The purpose of this study was to evaluate validity and reliability of the Farsi version of NIH Task Force's recommended multidimensional minimal dataset for research on chronic low back pain (CLBP). Considering the high treatment cost of CLBP and its increasing prevalence, NIH Pain Consortium developed research standards (including recommendations for definitions, a minimum dataset, and outcomes' report) for studies regarding CLBP. Application of these recommendations could standardize research and improve comparability of different studies in CLBP. This study has three phases: translation of dataset into Farsi and its cultural adaptation, assessment of pre-final version of dataset's comprehensibility via a pilot study, and investigation of the reliability and validity of final version of translated dataset. Subjects were 250 patients with CLBP. Test-retest reliability, content validity, and convergent validity (correlations among different dimensions of dataset and Farsi versions of Oswestry Disability Index, Roland Morris Disability Questionnaire, Fear-Avoidance Belief Questionnaire, and Beck Depression Inventory-II) were assessed. The Farsi version demonstrated good/excellent convergent validity (the correlation coefficient between impact dimension and ODI was r = 0.75 [P < 0.001], between impact dimension and Roland-Morris Disability Questionnaire was r = 0.80 [P < 0.001], and between psychological dimension and BDI was r = 0.62 [P < 0.001]). The test-retest reliability was also strong (intraclass correlation coefficient value ranged between 0.70 and 0.95) and the internal consistency was good/excellent (Chronbach's alpha coefficients' value for two main dimensions including impact dimension and psychological dimension were 0.91 and 0.82 [P < 0.001], respectively). In addition, its face validity and content validity were acceptable. The Farsi version of minimal dataset for research on CLBP is a reliable and valid instrument for data gathering in patients with CLBP. This minimum dataset can be a step toward standardization of research regarding CLBP. 3.

Top