Sample records for demonstrated comparable performance

  1. Everyday action in schizophrenia: performance patterns and underlying cognitive mechanisms.

    PubMed

    Kessler, Rachel K; Giovannetti, Tania; MacMullen, Laura R

    2007-07-01

    Everyday action is impaired among individuals with schizophrenia, yet few studies have characterized the nature of this deficit using performance-based measures. This study examined the performance of 20 individuals with schizophrenia or schizoaffective disorder on the Naturalistic Action Test (M. F. Schwartz, L. J. Buxbaum, M. Ferraro, T. Veramonti, & M. Segal, 2003). Performance was coded to examine overall impairment, task accomplishment, and error patterns and was compared with that of healthy controls (n = 28) and individuals with mild dementia (n = 23). Additionally, 2 competing accounts of everyday action deficits, the resource theory and an executive account, were evaluated. When compared with controls, the participants with schizophrenia demonstrated impaired performance. Relative to dementia patients, participants with schizophrenia obtained higher accomplishment scores but committed comparable rates of errors. Moreover, distributions of error types for the 2 groups differed, with the participants with schizophrenia demonstrating greater proportions of errors associated with executive dysfunction. This is the 1st study to show different Naturalistic Action Test performance patterns between 2 neurologically impaired populations. The distinct performance pattern demonstrated by individuals with schizophrenia reflects specific deficits in executive function.

  2. Impact of CCL2 and CCR2 Chemokine / Receptor Deficiencies on Macrophage Recruitment and Continuous Glucose Monitoring in vivo

    PubMed Central

    Klueh, Ulrike; Czajkowski, Caroline; Ludzinska, Izabela; Qiao, Yi; Frailey, Jackman; Kreutzer, Donald L.

    2016-01-01

    The accumulation of macrophages (MΦ) at the sensor-tissue interface is thought to be a major player in controlling tissue reactions and sensor performance in vivo. Nevertheless until recently no direct demonstration of the causal relationship between MΦ aggregation and loss of sensor function existed. Using a Continuous Glucose Monitoring (CGM) murine model we previously demonstrated that genetic deficiencies of MΦ or depletion of MΦ decreased MΦ accumulation at sensor implantation sites, which led to significantly enhanced CGM performance, when compared to normal mice. Additional studies in our laboratories have also demonstrated that MΦ can act as “metabolic sinks” by depleting glucose levels at the implanted sensors in vitro and in vivo. In the present study we extended these observations by demonstrating that MΦ chemokine (CCL2) and receptor (CCR2) knockout mice displayed a decrease in inflammation and MΦ recruitment at sensor implantation sites, when compared to normal mice. This decreased MΦ recruitment significantly enhanced CGM performance when compared to control mice. These studies demonstrated the importance of the CCL2 family of chemokines and related receptors in MΦ recruitment and sensor performance and suggest chemokine targets for enhancing CGM in vivo. PMID:27376197

  3. Economic evaluation of DSS 13 unattended operations demonstration

    NASA Technical Reports Server (NTRS)

    Remer, D. S.; Eisenberger, I.; Lorden, G.

    1978-01-01

    The goals and data collection requirements to be used for the economic and performance evaluation indexes and life cycle cost parameters for the upcoming operations demonstration of an automated Deep Space Station (DSS) run unattended and controlled remotely from JPL are presented. These evaluation indexes compare the remote operation of telemetry at DSS 13 with the cost and performance of a comparable manned operation at DSS 11. A description is presented of the data that needs to be collected, how the data will be analyzed, and what can and cannot be learned from this operations demonstration.

  4. Future applications of associative processor systems to operational KSC systems for optimizing cost and enhancing performance characteristics

    NASA Technical Reports Server (NTRS)

    Perkinson, J. A.

    1974-01-01

    The application of associative memory processor equipment to conventional host processors type systems is discussed. Efforts were made to demonstrate how such application relieves the task burden of conventional systems, and enhance system speed and efficiency. Data cover comparative theoretical performance analysis, demonstration of expanded growth capabilities, and demonstrations of actual hardware in simulated environment.

  5. Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics.

    PubMed

    Bakaraju, Ravi C; Ehrmann, Klaus; Ho, Arthur

    To compare the computed optical performance of prototype lenses designed using deliberate manipulation of higher-order spherical aberrations to extend depth-of-focus (EDOF) with two commercial multifocals. Emmetropic, presbyopic, schematic eyes were coupled with prototype EDOF and commercial multifocal lenses (Acuvue Oasys for presbyopia, AOP, Johnson & Johnson & Air Optix Aqua multifocal, AOMF, Alcon). For each test configuration, the through-focus retinal image quality (TFRIQ) values were computed over 21 vergences, ranging from -0.50 to 2.00D, in 0.125D steps. Analysis was performed considering eyes with three different inherent aberration profiles: five different pupils and five different lens decentration levels. Except the LOW design, the AOP lenses offered 'bifocal' like TFRIQ performance. Lens performance was relatively independent to pupil and aberrations but not centration. Contrastingly, AOMF demonstrated distance centric performance, most dominant in LOW followed by MED and HIGH designs. AOMF lenses were the most sensitive to pupil, aberrations and centration. The prototypes demonstrated a 'lift-off' in the TFRIQ performance, particularly at intermediate and near, without trading performance at distance. When compared with AOP and AOMF, EDOF lenses demonstrated reduced sensitivity to pupil, aberrations and centration. With the through focus retinal image quality as the gauge of optical performance, we demonstrated that the prototype EDOF designs were less susceptible to variations in pupil, inherent ocular aberrations and decentration, compared to the commercial designs. To ascertain whether these incremental improvements translate to a clinically palpable outcome requires investigation through human trials. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  6. Gait performance of children and adolescents with sensorineural hearing loss.

    PubMed

    Melo, Renato de Souza

    2017-09-01

    Several studies have demonstrated that children with sensorineural hearing loss (SNHL) may exhibit balance disorders, which can compromise the gait performance of this population. Compare the gait performance of normal hearing (NH) children and those with SNHL, considering the sex and age range of the sample, and analyze gait performance according to degrees of hearing loss and etiological factors in the latter group. This is a cross-sectional study that assessed 96 students, 48 NH and 48 with SNHL, aged between 7 and 18 years. The Brazilian version of the Dynamic Gait Index (DGI) was used to analyze gait and the Mann-Whitney test for statistical analysis. The group with SNHL obtained lower average gait performance compared to NH subjects (p=0.000). This was also observed when the children were grouped by sex female and male (p=0.000). The same difference occurred when the children were stratified by age group: 7-18 years (p=0.000). The group with severe and profound hearing loss exhibited worse gait performance than those with mild and moderate loss (p=0.048) and children with prematurity as an etiological factor demonstrated the worst gait performance. The children with SNHL showed worse gait performance compared to NH of the same sex and age group. Those with severe and profound hearing loss and prematurity as an etiological factor demonstrated the worst gait performances. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A Pilot Study Assessing Performance and Visual Attention of Teenagers with ASD in a Novel Adaptive Driving Simulator

    ERIC Educational Resources Information Center

    Wade, Joshua; Weitlauf, Amy; Broderick, Neill; Swanson, Amy; Zhang, Lian; Bian, Dayi; Sarkar, Medha; Warren, Zachary; Sarkar, Nilanjan

    2017-01-01

    Individuals with Autism Spectrum Disorder (ASD), compared to typically-developed peers, may demonstrate behaviors that are counter to safe driving. The current work examines the use of a novel simulator in two separate studies. Study 1 demonstrates statistically significant performance differences between individuals with (N = 7) and without ASD…

  8. Criterion Validity and Practical Utility of the Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF) in Assessments of Police Officer Candidates.

    PubMed

    Tarescavage, Anthony M; Corey, David M; Gupton, Herbert M; Ben-Porath, Yossef S

    2015-01-01

    Minnesota Multiphasic Personality Inventory-2-Restructured Form scores for 145 male police officer candidates were compared with supervisor ratings of field performance and problem behaviors during their initial probationary period. Results indicated that the officers produced meaningfully lower and less variant substantive scale scores compared to the general population. After applying a statistical correction for range restriction, substantive scale scores from all domains assessed by the inventory demonstrated moderate to large correlations with performance criteria. The practical significance of these results was assessed with relative risk ratio analyses that examined the utility of specific cutoffs on scales demonstrating associations with performance criteria.

  9. Effects of Elastic Resistance Exercise on Muscle Strength and Functional Performance in Healthy Adults: A Systematic Review and Meta-Analysis.

    PubMed

    de Oliveira, Poliana Alves; Blasczyk, Juscelino Castro; Souza Junior, Gerson; Lagoa, Karina Ferreira; Soares, Milene; de Oliveira, Ricardo Jacó; Filho, Paulo José Barbosa Gutierres; Carregaro, Rodrigo Luiz; Martins, Wagner Rodrigues

    2017-04-01

    Elastic Resistance Exercise (ERE) has already demonstrated its effectiveness in older adults and, when combined with the resistance generated by fixed loads, in adults. This review summarizes the effectiveness of ERE performed as isolated method on muscle strength and functional performance in healthy adults. A database search was performed (MEDLine, Cochrane Library, PEDro and Web of Knowledge) to identify controlled clinical trials in English language. The mean difference (MD) with 95% confidence intervals (CIs) and overall effect size were calculated for all comparisons. The PEDro scale was used assess the methodological quality. From the 93 articles identified by the search strategy, 5 met the inclusion criteria, in which 3 presented high quality (PEDro > 6). Meta-analyses demonstrated that the effects of ERE were superior when compared with passive control on functional performance and muscle strength. When compared with active controls, the effect of ERE was inferior on function performance and with similar effect on muscle strength. ERE are effective to improve functional performance and muscle strength when compared with no intervention, in healthy adults. ERE are not superior to other methods of resistance training to improve functional performance and muscle strength in health adults.

  10. Neuropsychological outcome in patients with childhood craniopharyngioma and hypothalamic involvement.

    PubMed

    Özyurt, Jale; Thiel, Christiane M; Lorenzen, Anna; Gebhardt, Ursel; Calaminus, Gabriele; Warmuth-Metz, Monika; Müller, Hermann L

    2014-04-01

    To test memory performance and executive functions in patients with childhood craniopharyngioma and hypothalamic involvement. Using standardized neuropsychological tests, we compared cognitive performance in a group of 15 patients with childhood craniopharyngioma and known hypothalamic involvement and a group of 24 age- and intelligence-matched control subjects. In addition, we compared individual patients' results with normative data to detect abnormal performance in the clinically relevant range. Within the patient group, we further tested whether the grade of hypothalamic involvement had an impact on cognitive performance and quality of life. Relative to healthy controls, the patients demonstrated significantly lower performance scores in tests of memory and executive functioning. On the individual performance level, delayed recall performance was severely impaired in one-third of the patients. Compared with patients with low-grade hypothalamic involvement, those with high-grade hypothalamic involvement showed worse performance in executive functions and reduced functional capabilities for daily life actions, indicating lower quality of life. Our findings demonstrate that hypothalamic involvement is related to impairments in memory and executive functioning in patients with childhood craniopharyngioma and indicate that a high grade of hypothalamic involvement is related to worse outcomes. Copyright © 2014 Mosby, Inc. All rights reserved.

  11. Visual acuity in young elite motorsport athletes: a preliminary report.

    PubMed

    Schneiders, Anthony G; Sullivan, S John; Rathbone, Emma J; Louise Thayer, A; Wallis, Laura M; Wilson, Alexandra E

    2010-05-01

    To determine whether elite motorsport athletes demonstrate superior levels of Visual Acuity than age and sex-matched controls. A cross-sectional observational study. A University vision and balance laboratory. Young male motorsport athletes from the New Zealand Elite Motorsport Academy and healthy age and sex-matched controls. Vision performance tests comprising; Static Visual Acuity (SVA), Dynamic Visual Acuity (DVA), Gaze Stabilization Test (GST), and the Perception Time Test (PTT). Motorsport athletes demonstrated superior visual acuity compared to age and sex-matched controls for all measures, and while this was not statistically significant for SVA, GST and DVA, it reached statistical significance for the PTT (p

  12. RM2: rms error comparisons

    NASA Technical Reports Server (NTRS)

    Rice, R. F.

    1976-01-01

    The root-mean-square error performance measure is used to compare the relative performance of several widely known source coding algorithms with the RM2 image data compression system. The results demonstrate that RM2 has a uniformly significant performance advantage.

  13. Relative Effects of Programmed Instruction and Demonstration Methods on Students' Academic Performance in Science

    ERIC Educational Resources Information Center

    Uhumuavbi, P. O.; Mamudu, J. A.

    2009-01-01

    This study compared the effects of Programmed Instruction and Demonstration methods on students academic performance in science in Esan West Local Government Area of Edo State. A sampling technique (balloting) was used in selecting two schools in Esan West local government area for the study. Two intact classes of fifty (50) students each from the…

  14. Technology demonstrator program for Space Station Environmental Control Life Support System

    NASA Technical Reports Server (NTRS)

    Adams, Alan M.; Platt, Gordon K.; Claunch, William C.; Humphries, William R.

    1987-01-01

    The main objectives and requirements of the NASA/Marshall Space Flight Center Technology Demonstration Program are discussed. The program consists of a comparative test and a 90-day manned system test to evaluate an Environmental Control and Life Support System (ECLSS). In the comparative test phase, 14 types of subsystems which perform oxygen and water reclamation functions are to be examined in terms of performance maintenance/service requirements, reliability, and safety. The manned chamber testing phase involves a four person crew using a partial ECLSS for 90 days. The schedule for the program and the program hardware requirements are described.

  15. Rectenna array measurement results

    NASA Technical Reports Server (NTRS)

    Dickinson, R. M.

    1980-01-01

    The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining were demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

  16. Comparison of active-learning strategies for motivational interviewing skills, knowledge, and confidence in first-year pharmacy students.

    PubMed

    Lupu, Ana M; Stewart, Autumn L; O'Neil, Christine

    2012-03-12

    To compare 3 strategies for pharmacy student learning of motivational interviewing skills, knowledge of motivational interviewing principles, and confidence in and attitudes toward their application. Following a motivational interviewing lecture, first-year students were randomized to perform practice activities (written dialogue, peer role-play, or mock-patient counseling activities). Motivational interviewing skills, knowledge, confidence, and attitudes were measured. All students demonstrated improvement in skills, knowledge, and confidence. Students in the mock-patient counseling group demonstrated significantly better motivational interviewing skills during practice and trended toward higher scores on the summative evaluation. They also demonstrated a significant improvement in knowledge compared with that of the written dialogue group during practice. Feedback at the end was generally positive, with students expressing recognition for the value of motivational interviewing. Students demonstrated their best performance of motivational interviewing during assessments using interactions with mock or standardized patients.

  17. Demonstration and evaluation of gas turbine transit buses

    NASA Technical Reports Server (NTRS)

    1983-01-01

    The Gas Turbine Transit Bus Demonstration Program was designed to demonstrate and evaluate the operation of gas turbine engines in transit coaches in revenue service compared with diesel powered coaches. The main objective of the program was to accelerate development and commercialization of automotive gas turbines. The benefits from the installation of this engine in a transit coach were expected to be reduced weight, cleaner exhaust emissions, lower noise levels, reduced engine vibration and maintenance requirements, improved reliability and vehicle performance, greater engine braking capability, and superior cold weather starting. Four RTS-II advanced design transit coaches were converted to gas turbine power using engines and transmissions. Development, acceptance, performance and systems tests were performed on the coaches prior to the revenue service demonstration.

  18. Optimization of the performance of the polymerase chain reaction in silicon-based microstructures.

    PubMed Central

    Taylor, T B; Winn-Deen, E S; Picozza, E; Woudenberg, T M; Albin, M

    1997-01-01

    We have demonstrated the ability to perform real-time homogeneous, sequence specific detection of PCR products in silicon microstructures. Optimal design/ processing result in equivalent performance (yield and specificity) for high surface-to-volume silicon structures as compared to larger volume reactions in polypropylene tubes. Amplifications in volumes as small as 0.5 microl and thermal cycling times reduced as much as 5-fold from that of conventional systems have been demonstrated for the microstructures. PMID:9224619

  19. High Temperature Performance Evaluation of a Compliant Foil Seal

    NASA Technical Reports Server (NTRS)

    Salehi, Mohsen; Heshmat, Hooshang; Walton, James F., II

    2001-01-01

    The key points to be gleaned from the effort reported herein are that the CFS (Compliant Foil Seal) has been demonstrated in conjunction with a foil bearing in a small gas turbine simulator at temperatures as high as 1000 F and outperformed a comparable brush seal. Having demonstrated the feasibility of the CFS, it would appear that this new seal design has application potential in a wide range of machines. What remains is to demonstrate performance at higher pressure ratios, consistent performance at large rotor excursions and the ability to manufacture the seal in much larger sizes exceeding by an order of magnitude that which has been tested to date.

  20. Relative benefits of stimulant therapy with OROS methylphenidate versus mixed amphetamine salts extended release in improving the driving performance of adolescent drivers with attention-deficit/hyperactivity disorder.

    PubMed

    Cox, Daniel J; Merkel, R Lawrence; Moore, Melissa; Thorndike, Frances; Muller, Carrie; Kovatchev, Boris

    2006-09-01

    Automobile accidents are the leading cause of death among adolescents, and collisions are 2 to 4 times more likely to occur among adolescents with attention-deficit/hyperactivity disorder. Studies have demonstrated that stimulants improve driving performance. This study compared 2 long-acting stimulant medications during daytime and evening driving evaluations. Adolescent drivers with attention-deficit/hyperactivity disorder were compared on a driving simulator after taking 72 mg of OROS methylphenidate, 30 mg of mixed amphetamine salts extended release, or placebo in a randomized, double-blind, placebo-controlled, crossover study design. During laboratory testing, adolescents drove a driving simulator at 5:00 pm, 8:00 pm, and 11:00 pm. Driving performance was rated by adolescents and investigators. The study included 35 adolescent drivers with attention-deficit/hyperactivity disorder (19 boys/16 girls). The mean age was 17.8 years. The overall Impaired Driving Score demonstrated that OROS methylphenidate led to better driving performance compared with placebo and mixed amphetamine salts extended release, whereas mixed amphetamine salts extended release demonstrated no statistical improvement over placebo. Specifically, relative to placebo, OROS methylphenidate resulted in less time driving off the road, fewer instances of speeding, less erratic speed control, more time executing left turns, and less inappropriate use of brakes. OROS methylphenidate and mixed amphetamine salts extended release worked equally well for male and female adolescents and equally as well with teenagers who have combined and inattentive subtypes of attention-deficit/hyperactivity disorder. This study validates the use of stimulants to improve driving performance in adolescents with attention-deficit/hyperactivity disorder. In the study, OROS methylphenidate promoted significantly improved driving performance compared with placebo and mixed amphetamine salts extended release.

  1. The Responses of Economically Advantaged and Economically Disadvantaged Sixth Grade Pupils to Science Demonstrations.

    ERIC Educational Resources Information Center

    Wagner, Bartlett Adam

    Compared were written, oral, and construction responses to science demonstrations of economically advantaged and disadvantaged sixth grade students. The study was designed to gain a greater understanding of academic performance of disadvantaged pupils in elementary school science. Five demonstrations were presented to each pupil, who then wrote…

  2. Enhanced performance of microbial fuel cell with a bacteria/multi-walled carbon nanotube hybrid biofilm

    NASA Astrophysics Data System (ADS)

    Zhang, Peng; Liu, Jia; Qu, Youpeng; Zhang, Jian; Zhong, Yingjuan; Feng, Yujie

    2017-09-01

    The biofilm on the anode of a microbial fuel cell (MFC) is a vital component in system, and its formation and characteristic determines the performance of the system. In this study, a bacteria/Multi-Walled Carbon Nanotube (MWCNT) hybrid biofilm is fabricated by effectively inserting the MWCNTs into the anode biofilm via an adsorption-filtration method. This hybrid biofilm has been demonstrated to be an efficient structure for improving an anode biofilm performance. Electrochemical impedance spectroscopy (EIS) results show that the hybrid biofilm takes advantage of the conductivity and structure of MWCNT to enhance the electron transfer and substrate diffusion of the biofilm. With this hybrid biofilm, the current density, power density and coulombic efficiency are increased by 46.2%, 58.8% and 84.6%, respectively, relative to naturally grown biofilm. Furthermore, the start-up time is reduced by 53.8% compared with naturally grown biofilm. The perturbation test demonstrates that this type of hybrid biofilm exhibits strong adsorption ability and enhances the biofilm's resistance to a sudden change of substrate concentration. The superior performance of the hybrid biofilm with MWCNT ;nanowire; matrix compared with naturally grown biofilm demonstrates its great potential for boosting the performance of MFCs.

  3. Neurofunctional Differences Associated with Arithmetic Processing in Turner Syndrome

    PubMed Central

    Kesler, Shelli R.; Menon, Vinod; Reiss, Allan L.

    2011-01-01

    Turner syndrome (TS) is a neurogenetic disorder characterized by the absence of one X chromosome in a phenotypic female. Individuals with TS are at risk for impairments in mathematics. We investigated the neural mechanisms underlying arithmetic processing in TS. Fifteen subjects with TS and 15 age-matched typically developing controls were scanned using functional MRI while they performed easy (two-operand) and difficult (three-operand) versions of an arithmetic processing task. Both groups activated fronto-parietal regions involved in arithmetic processing during the math tasks. Compared with controls, the TS group recruited additional neural resources in frontal and parietal regions during the easier, two-operand math task. During the more difficult three-operand task, individuals with TS demonstrated significantly less activation in frontal, parietal and subcortical regions than controls. However, the TS group’s performance on both math tasks was comparable to controls. Individuals with TS demonstrate activation differences in fronto-parietal areas during arithmetic tasks compared with controls. They must recruit additional brain regions during a relatively easy task and demonstrate a potentially inefficient response to increased task difficulty compared with controls. PMID:16135780

  4. Air traffic control specialists in the Airway Science Curriculum Demonstration Project 1984-1990 : third summative report.

    DOT National Transportation Integrated Search

    1991-12-01

    The objective of this summative evaluation of the Airway Science Curriculum Demonstration Project (ASCDP) was to compare the performance, job attitudes, retention rates, and perceived supervisory potential of graduates from recognized Airway Science ...

  5. VAS demonstration: (VISSR Atmospheric Sounder) description

    NASA Technical Reports Server (NTRS)

    Montgomery, H. E.; Uccellini, L. W.

    1985-01-01

    The VAS Demonstration (VISSR Atmospheric Sounder) is a project designed to evaluate the VAS instrument as a remote sensor of the Earth's atmosphere and surface. This report describes the instrument and ground processing system, the instrument performance, the valiation as a temperature and moisture profiler compared with ground truth and other satellites, and assesses its performance as a valuable meteorological tool. The report also addresses the availability of data for scientific research.

  6. Academic Performance of Students without Disabilities in the Inclusive Environment

    ERIC Educational Resources Information Center

    Fruth, Jason D.; Woods, Melanie N.

    2015-01-01

    This study examines the impact of inclusion on secondary students by focusing on the performance of students without disabilities in the inclusive environment compared to their performance in a segregated environment. Many studies exist demonstrating the positive impact of the inclusive environment on the performance of students with disabilities.…

  7. Accelerating Sequences in the Presence of Metal by Exploiting the Spatial Distribution of Off-Resonance

    PubMed Central

    Smith, Matthew R.; Artz, Nathan S.; Koch, Kevin M.; Samsonov, Alexey; Reeder, Scott B.

    2014-01-01

    Purpose To demonstrate feasibility of exploiting the spatial distribution of off-resonance surrounding metallic implants for accelerating multispectral imaging techniques. Theory Multispectral imaging (MSI) techniques perform time-consuming independent 3D acquisitions with varying RF frequency offsets to address the extreme off-resonance from metallic implants. Each off-resonance bin provides a unique spatial sensitivity that is analogous to the sensitivity of a receiver coil, and therefore provides a unique opportunity for acceleration. Methods Fully sampled MSI was performed to demonstrate retrospective acceleration. A uniform sampling pattern across off-resonance bins was compared to several adaptive sampling strategies using a total hip replacement phantom. Monte Carlo simulations were performed to compare noise propagation of two of these strategies. With a total knee replacement phantom, positive and negative off-resonance bins were strategically sampled with respect to the B0 field to minimize aliasing. Reconstructions were performed with a parallel imaging framework to demonstrate retrospective acceleration. Results An adaptive sampling scheme dramatically improved reconstruction quality, which was supported by the noise propagation analysis. Independent acceleration of negative and positive off-resonance bins demonstrated reduced overlapping of aliased signal to improve the reconstruction. Conclusion This work presents the feasibility of acceleration in the presence of metal by exploiting the spatial sensitivities of off-resonance bins. PMID:24431210

  8. Rectenna array measurement results. [Satellite power transmission and reception

    NASA Technical Reports Server (NTRS)

    Dickinson, R. M.

    1980-01-01

    The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining are demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array are demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

  9. Comparing the functional performance of children and youths with autism, developmental disabilities, and no disability using the revised pediatric evaluation of disability inventory item banks.

    PubMed

    Kao, Ying-Chia; Kramer, Jessica M; Liljenquist, Kendra; Tian, Feng; Coster, Wendy J

    2012-01-01

    OBJECTIVE. We compared the functional performance of children with autism spectrum disorders (ASD), intellectual and developmental disabilities (IDD), and without disabilities using the revised Pediatric Evaluation of Disability Inventory-Computer Adaptive Test (PEDI-CAT) Social/Cognitive, Daily Activities, and Responsibility domains. METHOD. A nationally representative sample of parents of children ages 0-21 without disabilities (n = 2,205), with ASD (n = 108), or with IDD (n = 150) completed an online survey. We obtained predicted PEDI-CAT scaled scores for three reference ages (5, 10, 15) from a modified analysis of covariance model and compared each group's scores using contrasts of the regression parameters. RESULTS. We found no significant differences between the ASD and IDD groups. The group with ASD demonstrated significantly lower performance than the group without disabilities across the three domains at ages 10 and 15. CONCLUSION. Scores on the PEDI-CAT differentiated the group with ASD from the group without disabilities. Children with ASD and IDD did not demonstrate different performance profiles. Copyright © 2012 by the American Occupational Therapy Association, Inc.

  10. Silicon Carbide Diodes Performance Characterization at High Temperatures

    NASA Technical Reports Server (NTRS)

    Lebron-Velilla, Ramon C.; Schwarze, Gene E.; Gardner, Brent G.; Adams, Jerry

    2004-01-01

    NASA Glenn Research center's Electrical Systems Development branch is working to demonstrate and test the advantages of Silicon Carbide (SiC) devices in actual power electronics applications. The first step in this pursuit is to obtain commercially available SiC Schottky diodes and to individually test them under both static and dynamic conditions, and then compare them with current state of the art silicon Schottky and ultra fast p-n diodes of similar voltage and current ratings. This presentation covers the results of electrical tests performed at NASA Glenn. Steady state forward and reverse current-volt (I-V) curves were generated for each device to compare performance and to measure their forward voltage drop at rated current, as well as the reverse leakage current at rated voltage. In addition, the devices were individually connected as freewheeling diodes in a Buck (step down) DC to DC converter to test their reverse recovery characteristics and compare their transient performance in a typical converter application. Both static and transient characterization tests were performed at temperatures ranging from 25 C to 300 C, in order to test and demonstrate the advantages of SiC over Silicon at high temperatures.

  11. Personalized Video Feedback and Repeated Task Practice Improve Laparoscopic Knot-Tying Skills: Two Controlled Trials.

    PubMed

    Abbott, Eduardo F; Thompson, Whitney; Pandian, T K; Zendejas, Benjamin; Farley, David R; Cook, David A

    2017-11-01

    Compare the effect of personalized feedback (PF) vs. task demonstration (TD), both delivered via video, on laparoscopic knot-tying skills and perceived workload; and evaluate the effect of repeated practice. General surgery interns and research fellows completed four repetitions of a simulated laparoscopic knot-tying task at one-month intervals. Midway between repetitions, participants received via e-mail either a TD video (demonstration by an expert) or a PF video (video of their own performance with voiceover from a blinded senior surgeon). Each participant received at least one video per format, with sequence randomly assigned. Outcomes included performance scores and NASA Task Load Index (NASA-TLX) scores. To evaluate the effectiveness of repeated practice, scores from these trainees on a separate delayed retention test were compared against historical controls who did not have scheduled repetitions. Twenty-one trainees completed the randomized study. Mean change in performance scores was significantly greater for those receiving PF (difference = 23.1 of 150 [95% confidence interval (CI): 0, 46.2], P = .05). Perceived workload was also significantly reduced (difference = -3.0 of 20 [95% CI: -5.8, -0.3], P = .04). Compared with historical controls (N = 93), the 21 with scheduled repeated practice had higher scores on the laparoscopic knot-tying assessment two weeks after the final repetition (difference = 1.5 of 10 [95% CI: 0.2, 2.8], P = .02). Personalized video feedback improves trainees' procedural performance and perceived workload compared with a task demonstration video. Brief monthly practice sessions support skill acquisition and retention.

  12. How Need for Cognition Affects the Formation of Performance Expectancies at School

    ERIC Educational Resources Information Center

    Dickhauser, Oliver; Reinhard, Marc-Andre

    2009-01-01

    Individuals with low Need for Cognition (NFC) have been found to process information using a peripheral route compared to individuals higher in NFC. These differences affect the formation of performance expectancies. Based on previous work demonstrating that the formation of performance expectancies can be understood as an information processing…

  13. Optimization of Turbine Engine Cycle Analysis with Analytic Derivatives

    NASA Technical Reports Server (NTRS)

    Hearn, Tristan; Hendricks, Eric; Chin, Jeffrey; Gray, Justin; Moore, Kenneth T.

    2016-01-01

    A new engine cycle analysis tool, called Pycycle, was built using the OpenMDAO framework. Pycycle provides analytic derivatives allowing for an efficient use of gradient-based optimization methods on engine cycle models, without requiring the use of finite difference derivative approximation methods. To demonstrate this, a gradient-based design optimization was performed on a turbofan engine model. Results demonstrate very favorable performance compared to an optimization of an identical model using finite-difference approximated derivatives.

  14. Comparative analytical evaluation of the respiratory TaqMan Array Card with real-time PCR and commercial multi-pathogen assays.

    PubMed

    Harvey, John J; Chester, Stephanie; Burke, Stephen A; Ansbro, Marisela; Aden, Tricia; Gose, Remedios; Sciulli, Rebecca; Bai, Jing; DesJardin, Lucy; Benfer, Jeffrey L; Hall, Joshua; Smole, Sandra; Doan, Kimberly; Popowich, Michael D; St George, Kirsten; Quinlan, Tammy; Halse, Tanya A; Li, Zhen; Pérez-Osorio, Ailyn C; Glover, William A; Russell, Denny; Reisdorf, Erik; Whyte, Thomas; Whitaker, Brett; Hatcher, Cynthia; Srinivasan, Velusamy; Tatti, Kathleen; Tondella, Maria Lucia; Wang, Xin; Winchell, Jonas M; Mayer, Leonard W; Jernigan, Daniel; Mawle, Alison C

    2016-02-01

    In this study, a multicenter evaluation of the Life Technologies TaqMan(®) Array Card (TAC) with 21 custom viral and bacterial respiratory assays was performed on the Applied Biosystems ViiA™ 7 Real-Time PCR System. The goal of the study was to demonstrate the analytical performance of this platform when compared to identical individual pathogen specific laboratory developed tests (LDTs) designed at the Centers for Disease Control and Prevention (CDC), equivalent LDTs provided by state public health laboratories, or to three different commercial multi-respiratory panels. CDC and Association of Public Health Laboratories (APHL) LDTs had similar analytical sensitivities for viral pathogens, while several of the bacterial pathogen APHL LDTs demonstrated sensitivities one log higher than the corresponding CDC LDT. When compared to CDC LDTs, TAC assays were generally one to two logs less sensitive depending on the site performing the analysis. Finally, TAC assays were generally more sensitive than their counterparts in three different commercial multi-respiratory panels. TAC technology allows users to spot customized assays and design TAC layout, simplify assay setup, conserve specimen, dramatically reduce contamination potential, and as demonstrated in this study, analyze multiple samples in parallel with good reproducibility between instruments and operators. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Video game performances are preserved in ADHD children compared with controls.

    PubMed

    Bioulac, Stéphanie; Lallemand, Stéphanie; Fabrigoule, Colette; Thoumy, Anne-Laure; Philip, Pierre; Bouvard, Manuel Pierre

    2014-08-01

    Although ADHD and excessive video game playing have received some attention, few studies have explored the performances of ADHD children when playing video games. The authors hypothesized that performances of ADHD children would be as good as those of control children in motivating video games tasks but not in the Continuous Performance Test II (CPT II). The sample consisted of 26 ADHD children and 16 control children. Performances of ADHD and control children were compared on three commercially available games, on the repetition of every game, and on the CPT II. ADHD children had lower performances on the CPT II than did controls, but they exhibited equivalent performances to controls when playing video games at both sessions and on all three games. When playing video games, ADHD children present no difference in inhibitory performances compared with control children. This demonstrates that cognitive difficulties in ADHD are task dependent. © 2012 SAGE Publications.

  16. Assessing Multicultural Competence: Perceived versus Demonstrated Performance

    ERIC Educational Resources Information Center

    Cartwright, Brenda Y.; Daniels, Judy; Zhang, Shuqiang

    2008-01-01

    This study compares self-report scores generated by the Multicultural Awareness Knowledge Skills Survey-Counselor Edition-Revised (B. S. K. Kim, B. Y. Cartwright, P. A. Asay, & M. J. D'Andrea, 2003) with independent observer ratings of actual videotaped demonstrations of multicultural competence in response to a preselected case vignette.…

  17. Performance comparison of the 4th generation Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA on the EVOLIS™ automated system versus Abbott ARCHITECT HIV Ag/Ab Combo, Ortho Anti-HIV 1+2 EIA on Vitros ECi and Siemens HIV-1/O/2 enhanced on Advia Centaur.

    PubMed

    Mitchell, Elizabeth O; Stewart, Greg; Bajzik, Olivier; Ferret, Mathieu; Bentsen, Christopher; Shriver, M Kathleen

    2013-12-01

    A multisite study was conducted to evaluate the performance of the Bio-Rad 4th generation GS HIV Combo Ag/Ab EIA versus Abbott 4th generation ARCHITECT HIV Ag/Ab Combo. The performance of two 3rd generation EIAs, Ortho Diagnostics Anti-HIV 1+2 EIA and Siemens HIV 1/O/2 was also evaluated. Study objective was comparison of analytical HIV-1 p24 antigen detection, sensitivity in HIV-1 seroconversion panels, specificity in blood donors and two HIV false reactive panels. Analytical sensitivity was evaluated with International HIV-1 p24 antigen standards, the AFFSAPS (pg/mL) and WHO 90/636 (IU/mL) standards; sensitivity in acute infection was compared on 55 seroconversion samples, and specificity was evaluated on 1000 negative blood donors and two false reactive panels. GS HIV Combo Ag/Ab demonstrated better analytical HIV antigen sensitivity compared to ARCHITECT HIV Ag/Ab Combo: 0.41 IU/mL versus 1.2 IU/mL (WHO) and 12.7 pg/mL versus 20.1 pg/mL (AFSSAPS); GS HIV Combo Ag/Ab EIA also demonstrated slightly better specificity compared to ARCHITECT HIV Ag/Ab Combo (100% versus 99.7%). The 4th generation HIV Combo tests detected seroconversion 7-11 days earlier than the 3rd generation HIV antibody only EIAs. Both 4th generation immunoassays demonstrated excellent performance in sensitivity, with the reduction of the serological window period (7-11 days earlier detection than the 3rd generation HIV tests). However, GS HIV Combo Ag/Ab demonstrated improved HIV antigen analytical sensitivity and slightly better specificity when compared to ARCHITECT HIV Ag/Ab Combo assay, with higher positive predictive values (PPV) for low prevalence populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Interactive videodisc instruction is an alternative method for learning and performing a critical nursing skill.

    PubMed

    DeAmicis, P A

    1997-01-01

    A study was conducted to compare the effectiveness of interactive videodisc instruction (IVDI) with the traditional lecture/demonstration as an alternative method for learning and performing a critical nursing skill. Students were assigned randomly to a treatment group that worked in small groups to complete the IVDI on intravenous therapy skills and a control group receiving the same content in a classroom lecture/demonstration format. After the instruction, each subject performed a re-demonstration of the learned skills using specific guidelines. Results revealed that although the IVDI group scored higher on the overall re-demonstration, there was no significant difference in the ability of the two groups to effectively perform this critical nursing skill. These findings support the use of IVDI as an alternative self-paced, independent study method for learning psychomotor skills and are consistent with previous studies, which indicate that working in small groups on the computer has a positive effect on self-efficacy and achievement.

  19. Comparison of Appendectomy Outcomes Between Senior General Surgeons and General Surgery Residents.

    PubMed

    Siam, Baha; Al-Kurd, Abbas; Simanovsky, Natalia; Awesat, Haitham; Cohn, Yahav; Helou, Brigitte; Eid, Ahmed; Mazeh, Haggi

    2017-07-01

    In some centers, the presence of a senior general surgeon (SGS) is obligatory in every procedure, including appendectomy, while in others it is not. There is a relative paucity in the literature of reports comparing the outcomes of appendectomies performed by unsupervised general surgery residents (GSRs) with those performed in the presence of an SGS. To compare the outcomes of appendectomies performed by SGSs with those performed by GSRs. A retrospective analysis was performed of all patients 16 years or older operated on for assumed acute appendicitis between January 1, 2008, and December 31, 2015. The cohort study compared appendectomies performed by SGSs and GSRs in the general surgical department of a teaching hospital. The primary outcome measured was the postoperative early and late complication rates. Secondary outcomes included time from emergency department to operating room, length of surgery, surgical technique (open or laparoscopic), use of laparoscopic staplers, and overall duration of postoperative antibiotic treatment. Among 1649 appendectomy procedures (mean [SD] patient age, 33.7 [13.3] years; 612 female [37.1%]), 1101 were performed by SGSs and 548 by GSRs. Analysis demonstrated no significant difference between the SGS group and the GSR group in overall postoperative early and late complication rates, the use of imaging techniques, time from emergency department to operating room, percentage of complicated appendicitis, postoperative length of hospital stay, and overall duration of postoperative antibiotic treatment. However, length of surgery was significantly shorter in the SGS group than in the GSR group (mean [SD], 39.9 [20.9] vs 48.6 [20.2] minutes; P < .001). This study demonstrates that unsupervised surgical residents may safely perform appendectomies, with no difference in postoperative early and late complication rates compared with those performed in the presence of an SGS.

  20. During computing tasks symptomatic female office workers demonstrate a trend towards higher cervical postural muscle load than asymptomatic office workers: an experimental study.

    PubMed

    Szeto, Grace P Y; Straker, Leon M; O'Sullivan, Peter B

    2009-01-01

    Do symptomatic female office workers perform computing tasks with higher cervical postural muscle loads (in terms of higher amplitudes and less muscular rest) and more discomfort compared with asymptomatic individuals? Are these differences in postural muscle loads consistent across bilateral (typing) and unilateral (mousing) conditions? an experimental case-control study. 18 symptomatic female office workers and 21 asymptomatic female office workers. Three conditions (typing, mousing, and type-and-mouse) were performed in random order. Muscle load was measured as median amplitude and gap frequency using surface EMG of bilateral cervical erector spinae and upper trapezius. Discomfort was measured using a numerical rating scale. The case group demonstrated 4.3% (95% CI 0.1 to 8.4) higher amplitude during typing and 3.5% (95% CI 0.1 to 6.9) higher amplitude during type-and-mouse in the right cervical erector spinae compared with the control group. There was a similar difference between groups in the left cervical erector spinae which also demonstrated a 1.2 gaps/min (95% CI -2.3 to 0.0) lower frequency during typing. The case group had significantly higher discomfort during all conditions compared with the control group. The case group demonstrated higher median amplitudes and lower gap frequencies than the control group during bilateral conditions (typing and type-and-mouse) compared with unilateral conditions (mousing) for both muscle groups. There was increased amplitude and decreased muscular rest in the cervical erector spinae of office workers performing typing and mousing tasks. These findings may represent a mechanism underlying computer-related musculoskeletal disorders.

  1. European Multicenter Study on Analytical Performance of DxN Veris System HCV Assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Gismondo, Maria Rita; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Marcos, Maria Angeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W

    2017-04-01

    The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.22 log 10 IU/ml or lower for each level tested. Analytical sensitivity determined by probit analysis was between 6.2 and 9.0 IU/ml. Specificity on 94 unique patient samples was 100%, and performance with 1,089 negative samples demonstrated 100% not-detected results. Linearity using patient samples was shown from 1.34 to 6.94 log 10 IU/ml. The assay demonstrated linearity upon dilution with all HCV genotypes. The Veris HCV Assay demonstrated an analytical performance comparable to that of currently marketed HCV assays when tested across multiple European sites. Copyright © 2017 American Society for Microbiology.

  2. Mental Toughness Moderates Social Loafing in Cycle Time-Trial Performance.

    PubMed

    Haugen, Tommy; Reinboth, Michael; Hetlelid, Ken J; Peters, Derek M; Høigaard, Rune

    2016-09-01

    The purpose of this study was to determine if mental toughness moderated the occurrence of social loafing in cycle time-trial performance. Twenty-seven men (Mage = 17.7 years, SD = 0.6) completed the Sport Mental Toughness Questionnaire prior to completing a 1-min cycling trial under 2 conditions: once with individual performance identified, and once in a group with individual performance not identified. Using a median split of the mental toughness index, participants were divided into high and low mental toughness groups. Cycling distance was compared using a 2 (trial) × 2 (high-low mental toughness) analysis of variance. We hypothesized that mentally tough participants would perform equally well under both conditions (i.e., no indication of social loafing) compared with low mentally tough participants, who would perform less well when their individual performance was not identifiable (i.e., demonstrating the anticipated social loafing effect). The high mental toughness group demonstrated consistent performance across both conditions, while the low mental toughness group reduced their effort in the non-individually identifiable team condition. The results confirm that (a) clearly identifying individual effort/performance is an important situational variable that may impact team performance and (b) higher perceived mental toughness has the ability to negate the tendency to loaf.

  3. Acute, low-dose methamphetamine administration improves attention/information processing speed and working memory in methamphetamine-dependent individuals displaying poorer cognitive performance at baseline

    PubMed Central

    Mahoney, James J.; Jackson, Brian J.; Kalechstein, Ari D.; De La Garza, Richard; Newton, Thomas F.

    2012-01-01

    Abstinent methamphetamine (Meth) dependent individuals demonstrate poorer performance on tests sensitive to attention/information processing speed, learning and memory, and working memory when compared to non-Meth dependent individuals. The poorer performance on these tests may contribute to the morbidity associated with Meth-dependence. In light of this, we sought to determine the effects of acute, low-dose Meth administration on attention, working memory, and verbal learning and memory in 19 non-treatment seeking, Meth-dependent individuals. Participants were predominantly male (89%), Caucasian (63%), and cigarette smokers (63%). Following a four day, drug-free washout period, participants were given a single-blind intravenous infusion of saline, followed the next day by 30 mg of Meth. A battery of neurocognitive tasks was administered before and after each infusion, and performance on measures of accuracy and reaction time were compared between conditions. While acute Meth exposure did not affect test performance for the entire sample, participants who demonstrated relatively poor performance on these tests at baseline, identified using a median split on each test, showed significant improvement on measures of attention/information processing speed and working memory when administered Meth. Improved performance was seen on the following measures of working memory: choice reaction time task (p≤0.04), a 1-back task (p≤0.01), and a 2-back task (p≤0.04). In addition, those participants demonstrating high neurocognitive performance at baseline experienced similar or decreased performance following Meth exposure. These findings suggest that acute administration of Meth may temporarily improve Meth-associated neurocognitive performance in those individuals experiencing lower cognitive performance at baseline. As a result, stimulants may serve as a successful treatment for improving cognitive functioning in those Meth-dependent individuals experiencing neurocognitive impairment. PMID:21122811

  4. The Knowledge Base and Memory Performance: A Comparison of Academically Successful and Unsuccessful Learners. Paper 5/1987.

    ERIC Educational Resources Information Center

    Schneider, Wolfgang; And Others

    The expert-novice paradigm, which demonstrates the outstanding role of domain-specific knowledge in explaining differences in memory behavior and performance, was examined. Two studies are described which compared memory performance of groups equivalent with regard to domain-specific knowledge but differing in intellectual ability. The hypothesis…

  5. Finite Element Modelling Full Vehicle Side Impact with Ultrahigh Strength Hot Stamped Steels

    NASA Astrophysics Data System (ADS)

    Taylor, T.; Fourlaris, G.; Cafolla, J.

    2016-10-01

    "Hot stamped boron steel" 22MnB5 has been imperative in meeting the automotive industry's demand for materials exhibiting higher tensile strength in the final component. In this paper, the crash performance of three experimental grades developed for automotive hot stamping technologies, exhibiting wider tensile property ranges than 22MnB5, was validated by finite element modelling full vehicle side impact with the experimental material data applied to the B-pillar reinforcement. The superior anti-intrusive crash performance of grade 38MnB5 was demonstrated, with 11 mm less intrusion of the B-pillar reinforcement compared to 22MnB5. Moreover, the superior "impact-energy absorptive" crash performance of grade 15MnCr5 was demonstrated, with 0.15 kJ greater impact-energy absorption by the B-pillar reinforcement compared to 22MnB5.

  6. Perception versus reality: a comparative study of the clinical judgment skills of nurses during a simulated activity.

    PubMed

    Fenske, Cynthia L; Harris, Margaret A; Aebersold, Michelle L; Hartman, Laurie S

    2013-09-01

    This study was conducted to determine how closely nurses' perceptions of their clinical judgment abilities matched their demonstrated clinical judgment skills during a simulation. Seventy-four registered nurses participated in a simulation using a video format. After the simulation, the nurses self-assessed their performance using the Lasater Clinical Judgment Rubric. This rubric was then used to rate the nurses' actual performance in the simulation activity. The study results showed a significant discrepancy between nurses' perceptions of their own clinical judgment abilities and their demonstrated clinical judgment skills. Age and length of nursing experience enhanced the difference between the findings of self-assessment and actual performance. Younger nurses and those with 1 year or less of nursing experience were significantly more likely to have self-assessed their abilities at a much higher level compared with their actual skills. Copyright 2013, SLACK Incorporated.

  7. Modified artificial bee colony algorithm for reactive power optimization

    NASA Astrophysics Data System (ADS)

    Sulaiman, Noorazliza; Mohamad-Saleh, Junita; Abro, Abdul Ghani

    2015-05-01

    Bio-inspired algorithms (BIAs) implemented to solve various optimization problems have shown promising results which are very important in this severely complex real-world. Artificial Bee Colony (ABC) algorithm, a kind of BIAs has demonstrated tremendous results as compared to other optimization algorithms. This paper presents a new modified ABC algorithm referred to as JA-ABC3 with the aim to enhance convergence speed and avoid premature convergence. The proposed algorithm has been simulated on ten commonly used benchmarks functions. Its performance has also been compared with other existing ABC variants. To justify its robust applicability, the proposed algorithm has been tested to solve Reactive Power Optimization problem. The results have shown that the proposed algorithm has superior performance to other existing ABC variants e.g. GABC, BABC1, BABC2, BsfABC dan IABC in terms of convergence speed. Furthermore, the proposed algorithm has also demonstrated excellence performance in solving Reactive Power Optimization problem.

  8. Spherical roller bearing analysis. SKF computer program SPHERBEAN. Volume 3: Program correlation with full scale hardware tests

    NASA Technical Reports Server (NTRS)

    Kleckner, R. J.; Rosenlieb, J. W.; Dyba, G.

    1980-01-01

    The results of a series of full scale hardware tests comparing predictions of the SPHERBEAN computer program with measured data are presented. The SPHERBEAN program predicts the thermomechanical performance characteristics of high speed lubricated double row spherical roller bearings. The degree of correlation between performance predicted by SPHERBEAN and measured data is demonstrated. Experimental and calculated performance data is compared over a range in speed up to 19,400 rpm (0.8 MDN) under pure radial, pure axial, and combined loads.

  9. Application of Micro-Electro-Mechanical Sensors Contactless NDT of Concrete Structures.

    PubMed

    Ham, Suyun; Popovics, John S

    2015-04-17

    The utility of micro-electro-mechanical sensors (MEMS) for application in air-coupled (contactless or noncontact) sensing to concrete nondestructive testing (NDT) is studied in this paper. The fundamental operation and characteristics of MEMS are first described. Then application of MEMS sensors toward established concrete test methods, including vibration resonance, impact-echo, ultrasonic surface wave, and multi-channel analysis of surface waves (MASW), is demonstrated. In each test application, the performance of MEMS is compared with conventional contactless and contact sensing technology. Favorable performance of the MEMS sensors demonstrates the potential of the technology for applied contactless NDT efforts. To illustrate the utility of air-coupled MEMS sensors for concrete NDT, as compared with conventional sensor technology.

  10. The Stock Performance of C. Everett Koop Award Winners Compared With the Standard & Poor's 500 Index.

    PubMed

    Goetzel, Ron Z; Fabius, Raymond; Fabius, Dan; Roemer, Enid C; Thornton, Nicole; Kelly, Rebecca K; Pelletier, Kenneth R

    2016-01-01

    To explore the link between companies investing in the health and well-being programs of their employees and stock market performance. Stock performance of C. Everett Koop National Health Award winners (n = 26) was measured over time and compared with the average performance of companies comprising the Standard and Poor's (S&P) 500 Index. The Koop Award portfolio outperformed the S&P 500 Index. In the 14-year period tracked (2000-2014), Koop Award winners' stock values appreciated by 325% compared with the market average appreciation of 105%. This study supports prior and ongoing research demonstrating a higher market valuation--an affirmation of business success by Wall Street investors--of socially responsible companies that invest in the health and well-being of their workers when compared with other publicly traded firms.

  11. 40 CFR 59.208 - Charcoal lighter material testing protocol.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the performance, design, and operation specifications of the prescribed equipment. A demonstration... Administrator prior to compliance testing, based on an evaluation of comparative performance specifications and... stack barbecue charcoal that is designed to be lit without the packaging, the same as in paragraph (h)(1...

  12. 40 CFR 59.208 - Charcoal lighter material testing protocol.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the performance, design, and operation specifications of the prescribed equipment. A demonstration... Administrator prior to compliance testing, based on an evaluation of comparative performance specifications and... stack barbecue charcoal that is designed to be lit without the packaging, the same as in paragraph (h)(1...

  13. 40 CFR 59.208 - Charcoal lighter material testing protocol.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the performance, design, and operation specifications of the prescribed equipment. A demonstration... Administrator prior to compliance testing, based on an evaluation of comparative performance specifications and... stack barbecue charcoal that is designed to be lit without the packaging, the same as in paragraph (h)(1...

  14. A randomized controlled pilot trial comparing the impact of access to clinical endocrinology video demonstrations with access to usual revision resources on medical student performance of clinical endocrinology skills

    PubMed Central

    2013-01-01

    Background Demonstrating competence in clinical skills is key to course completion for medical students. Methods of providing clinical instruction that foster immediate learning and potentially serve as longer-term repositories for on-demand revision, such as online videos demonstrating competent performance of clinical skills, are increasingly being used. However, their impact on learning has been little studied. The aim of this study was to determine the value of adjunctive on-demand video-based training for clinical skills acquisition by medical students in endocrinology. Methods Following an endocrinology clinical tutorial program, 2nd year medical students in the pre-assessment revision period were recruited and randomized to either a set of bespoke on-line clinical skills training videos (TV), or to revision as usual (RAU). The skills demonstrated on video were history taking in diabetes mellitus (DMH), examination for diabetes lower limb complications (LLE), and examination for signs of thyroid disease (TE). Students were assessed on these clinical skills in an observed structured clinical examination two weeks after randomization. Assessors were blinded to student randomization status. Results For both diabetes related clinical skills assessment tasks, students in the TV group performed significantly better than those in the RAU group. There were no between group differences in thyroid examination performance. For the LLE, 91.7% (n = 11/12) of students randomized to the video were rated globally as competent at the skill compared with 40% (n = 4/10) of students not randomized to the video (p = 0.024). For the DMH, 83.3% (n = 10/12) of students randomized to the video were rated globally as competent at the skill compared with 20% (n = 2/10) of students not randomized to the video (p = 0.007). Conclusion Exposure to high quality videos demonstrating clinical skills can significantly improve medical student skill performance in an observed structured clinical examination of these skills, when used as an adjunct to clinical skills face-to-face tutorials and deliberate practice of skills in a blended learning format. Video demonstrations can provide an enduring, on-demand, portable resource for revision, which can even be used at the bedside by learners. Such resources are cost-effectively scalable for large numbers of learners. PMID:24090039

  15. A randomized controlled pilot trial comparing the impact of access to clinical endocrinology video demonstrations with access to usual revision resources on medical student performance of clinical endocrinology skills.

    PubMed

    Hibbert, Emily J; Lambert, Tim; Carter, John N; Learoyd, Diana L; Twigg, Stephen; Clarke, Stephen

    2013-10-03

    Demonstrating competence in clinical skills is key to course completion for medical students. Methods of providing clinical instruction that foster immediate learning and potentially serve as longer-term repositories for on-demand revision, such as online videos demonstrating competent performance of clinical skills, are increasingly being used. However, their impact on learning has been little studied. The aim of this study was to determine the value of adjunctive on-demand video-based training for clinical skills acquisition by medical students in endocrinology. Following an endocrinology clinical tutorial program, 2nd year medical students in the pre-assessment revision period were recruited and randomized to either a set of bespoke on-line clinical skills training videos (TV), or to revision as usual (RAU). The skills demonstrated on video were history taking in diabetes mellitus (DMH), examination for diabetes lower limb complications (LLE), and examination for signs of thyroid disease (TE). Students were assessed on these clinical skills in an observed structured clinical examination two weeks after randomization. Assessors were blinded to student randomization status. For both diabetes related clinical skills assessment tasks, students in the TV group performed significantly better than those in the RAU group. There were no between group differences in thyroid examination performance. For the LLE, 91.7% (n = 11/12) of students randomized to the video were rated globally as competent at the skill compared with 40% (n = 4/10) of students not randomized to the video (p = 0.024). For the DMH, 83.3% (n = 10/12) of students randomized to the video were rated globally as competent at the skill compared with 20% (n = 2/10) of students not randomized to the video (p = 0.007). Exposure to high quality videos demonstrating clinical skills can significantly improve medical student skill performance in an observed structured clinical examination of these skills, when used as an adjunct to clinical skills face-to-face tutorials and deliberate practice of skills in a blended learning format. Video demonstrations can provide an enduring, on-demand, portable resource for revision, which can even be used at the bedside by learners. Such resources are cost-effectively scalable for large numbers of learners.

  16. Transfer of skills on LapSim virtual reality laparoscopic simulator into the operating room in urology.

    PubMed

    Alwaal, Amjad; Al-Qaoud, Talal M; Haddad, Richard L; Alzahrani, Tarek M; Delisle, Josee; Anidjar, Maurice

    2015-01-01

    Assessing the predictive validity of the LapSim simulator within a urology residency program. Twelve urology residents at McGill University were enrolled in the study between June 2008 and December 2011. The residents had weekly training on the LapSim that consisted of 3 tasks (cutting, clip-applying, and lifting and grasping). They underwent monthly assessment of their LapSim performance using total time, tissue damage and path length among other parameters as surrogates for their economy of movement and respect for tissue. The last residents' LapSim performance was compared with their first performance of radical nephrectomy on anesthetized porcine models in their 4(th) year of training. Two independent urologic surgeons rated the resident performance on the porcine models, and kappa test with standardized weight function was used to assess for inter-observer bias. Nonparametric spearman correlation test was used to compare each rater's cumulative score with the cumulative score obtained on the porcine models in order to test the predictive validity of the LapSim simulator. The kappa results demonstrated acceptable agreement between the two observers among all domains of the rating scale of performance except for confidence of movement and efficiency. In addition, poor predictive validity of the LapSim simulator was demonstrated. Predictive validity was not demonstrated for the LapSim simulator in the context of a urology residency training program.

  17. Subthalamic nucleus stimulation selectively improves motor and visual memory performance in Parkinson's disease.

    PubMed

    Mollion, Hélène; Dominey, Peter Ford; Broussolle, Emmanuel; Ventre-Dominey, Jocelyne

    2011-09-01

    Although the treatment of Parkinson's disease via subthalamic stimulation yields remarkable improvements in motor symptoms, its effects on memory function are less clear. In this context, we previously demonstrated dissociable effects of levodopa therapy on parkinsonian performance in spatial and nonspatial visual working memory. Here we used the same protocol with an additional, purely motor task to investigate visual memory and motor performance in 2 groups of patients with Parkinson's disease with or without subthalamic stimulation. In each stimulation condition, subjects performed a simple motor task and 3 successive cognitive tasks: 1 conditional color-response association task and 2 visual (spatial and nonspatial) working memory tasks. The Parkinson's groups were compared with a control group of age-matched healthy subjects. Our principal results demonstrated that (1) in the motor task, stimulated patients were significantly improved with respect to nonstimulated patients and did not differ significantly from healthy controls, and (2) in the cognitive tasks, stimulated patients were significantly improved with respect to nonstimulated patients, but both remained significantly impaired when compared with healthy controls. These results demonstrate selective effects of subthalamic stimulation on parkinsonian disorders of motor and visual memory functions, with clear motor improvement for stimulated patients and a partial improvement for their visual memory processing. Copyright © 2011 Movement Disorder Society.

  18. High-performance all-printed amorphous oxide FETs and logics with electronically compatible electrode/ channel interface.

    PubMed

    Sharma, Bhupendra Kumar; Stoesser, Anna; Mondal, Sandeep Kumar; Garlapati, Suresh K; Fawey, Mohammed H; Chakravadhanula, Venkata Sai Kiran; Kruk, Robert; Hahn, Horst; Dasgupta, Subho

    2018-06-12

    Oxide semiconductors typically show superior device performance compared to amorphous silicon or organic counterparts, especially, when they are physical vapor deposited. However, it is not easy to reproduce identical device characteristics when the oxide field-effect transistors (FETs) are solution-processed/ printed; the level of complexity further intensifies with the need to print the passive elements as well. Here, we developed a protocol for designing the most electronically compatible electrode/ channel interface based on the judicious material selection. Exploiting this newly developed fabrication schemes, we are now able to demonstrate high-performance all-printed FETs and logic circuits using amorphous indium-gallium-zinc oxide (a-IGZO) semiconductor, indium tin oxide (ITO) as electrodes and composite solid polymer electrolyte as the gate insulator. Interestingly, all-printed FETs demonstrate an optimal electrical performance in terms of threshold voltages and device mobility and may very well be compared with devices fabricated using sputtered ITO electrodes. This observation originates from the selection of electrode/ channel materials from the same transparent semiconductor oxide family, resulting in the formation of In-Sn-Zn-O (ITZO) based diffused a-IGZO/ ITO interface that controls doping density while ensuring high electrical performance. Compressive spectroscopic studies reveal that Sn doping mediated excellent band alignment of IGZO with ITO electrodes is responsible for the excellent device performance observed. All-printed n-MOS based logic circuits have also been demonstrated towards new-generation portable electronics.

  19. Performance analysis of a Principal Component Analysis ensemble classifier for Emotiv headset P300 spellers.

    PubMed

    Elsawy, Amr S; Eldawlatly, Seif; Taher, Mohamed; Aly, Gamal M

    2014-01-01

    The current trend to use Brain-Computer Interfaces (BCIs) with mobile devices mandates the development of efficient EEG data processing methods. In this paper, we demonstrate the performance of a Principal Component Analysis (PCA) ensemble classifier for P300-based spellers. We recorded EEG data from multiple subjects using the Emotiv neuroheadset in the context of a classical oddball P300 speller paradigm. We compare the performance of the proposed ensemble classifier to the performance of traditional feature extraction and classifier methods. Our results demonstrate the capability of the PCA ensemble classifier to classify P300 data recorded using the Emotiv neuroheadset with an average accuracy of 86.29% on cross-validation data. In addition, offline testing of the recorded data reveals an average classification accuracy of 73.3% that is significantly higher than that achieved using traditional methods. Finally, we demonstrate the effect of the parameters of the P300 speller paradigm on the performance of the method.

  20. Case Study for the ARRA-funded GSHP Demonstration at University at Albany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Xiaobing; Malhotra, Mini; Xiong, Zeyu

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects—a distributed GSHP system at a new 500-bed apartment-style student residence hall at the University at Albany. This case studymore » is based on the analysis of detailed design documents, measured performance data, published catalog data of heat pump equipment, and actual construction costs. Simulations with a calibrated computer model are performed for both the demonstrated GSHP system and a baseline heating, ventilation, and airconditioning (HVAC) system to determine the energy savings and other related benefits achieved by the GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, as well as the pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the demonstrated GSHP system compared with the baseline HVAC system. This case study also identifies opportunities for improving the operational efficiency of the demonstrated GSHP system.« less

  1. Demonstration of LED Retrofit Lamps at an Exhibit of 19th Century Photography at the Getty Museum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Naomi J.; Druzik, Jim

    This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL productsmore » against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program may have been prescreened for performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products. This report reviews the installation and use of LED PAR38 lamps to light a collection of toned albument photographic prints at the J. Paul Getty Museum in Malibu, California. Research results provided by the Getty Conservation Institute are incorporated and discussed.« less

  2. Interteaching: The Effects of Discussion Group Size on Undergraduate Student Performance and Preference

    ERIC Educational Resources Information Center

    Gutierrez, Michael

    2017-01-01

    Interteaching is a college teaching method grounded in the principles of applied behavior analysis. Research on interteaching demonstrates that it improves academic performance, and students report greater satisfaction with interteaching as compared to traditional teaching styles. The current study investigates whether discussion group size, a…

  3. Does Happiness Promote Career Success?

    ERIC Educational Resources Information Center

    Boehm, Julia K.; Lyubomirsky, Sonja

    2008-01-01

    Past research has demonstrated a relationship between happiness and workplace success. For example, compared with their less happy peers, happy people earn more money, display superior performance, and perform more helpful acts. Researchers have often assumed that an employee is happy and satisfied because he or she is successful. In this article,…

  4. Characterizing Discourse Deficits Following Penetrating Head Injury: A Preliminary Model

    ERIC Educational Resources Information Center

    Coelho, Carl; Le, Karen; Mozeiko, Jennifer; Hamilton, Mark; Tyler, Elizabeth; Krueger, Frank; Grafman, Jordan

    2013-01-01

    Purpose: Discourse analyses have demonstrated utility for delineating subtle communication deficits following closed head injuries (CHIs). The present investigation examined the discourse performance of a large group of individuals with penetrating head injury (PHI). Performance was also compared across 6 subgroups of PHI based on lesion locale. A…

  5. Children Born at Risk: What's Happening in Kindergarten?

    ERIC Educational Resources Information Center

    Reich, Jill N.; And Others

    1993-01-01

    Compared high-risk (n=20) versus low-risk (n=15) children in their performance on Wechsler Preschool Primary Intelligence Scale at pre- and postkindergarten levels. High-risk group had, at birth, experienced prematurity and/or illness. Both groups demonstrated increases in performance: high-risk children showed increases predominantly in…

  6. Brief Report: Performance Pattern Differences between Children with Autism Spectrum Disorders and Attention Deficit-Hyperactivity Disorder on Measures of Verbal Intelligence

    ERIC Educational Resources Information Center

    Zayat, Maya; Kalb, Luther; Wodka, Ericka L.

    2011-01-01

    Performance patterns on verbal subtests from the WISC-IV were compared between a clinically-referred sample of children with either autism spectrum disorders (ASD) or attention deficit/hyperactivity disorder (ADHD). Children with ASD demonstrated a statistically significant stepwise pattern where performance on Similarities was best, followed by…

  7. The Cluster Sensitivity Index: A Basic Measure of Classification Robustness

    ERIC Educational Resources Information Center

    Hom, Willard C.

    2010-01-01

    Analysts of institutional performance have occasionally used a peer grouping approach in which they compared institutions only to other institutions with similar characteristics. Because analysts historically have used cluster analysis to define peer groups (i.e., the group of comparable institutions), the author proposes and demonstrates with…

  8. Design, Fabrication, and Performance of Foil Gas Thrust Bearings for Microturbomachinery Applications

    NASA Technical Reports Server (NTRS)

    Dykas, Brian; Bruckner, Robert; DellaCorte, Christopher; Edmonds, Brian; Prahl, Joseph

    2008-01-01

    A methodology for the design and construction of simple foil thrust bearings intended for parametric performance testing and low marginal costs is presented. Features drawn from a review of the open literature are discussed as they relate to bearing performance. The design of fixtures and tooling required to fabricate foil thrust bearings is presented, using conventional machining processes where possible. A prototype bearing with dimensions drawn from the literature is constructed, with all fabrication steps described. A load-deflection curve for the bearing is presented to illustrate structural stiffness characteristics. Start-top cycles are performed on the bearing at a temperature of 425 C to demonstrate early-life wear patterns. A test of bearing load capacity demonstrates useful performance when compared with data obtained from the open literature.

  9. The Stock Performance of C. Everett Koop Award Winners Compared With the Standard & Poor's 500 Index

    PubMed Central

    Goetzel, Ron Z.; Fabius, Raymond; Fabius, Dan; Roemer, Enid C.; Thornton, Nicole; Kelly, Rebecca K.; Pelletier, Kenneth R.

    2016-01-01

    Objective: To explore the link between companies investing in the health and well-being programs of their employees and stock market performance. Methods: Stock performance of C. Everett Koop National Health Award winners (n = 26) was measured over time and compared with the average performance of companies comprising the Standard and Poor's (S&P) 500 Index. Results: The Koop Award portfolio outperformed the S&P 500 Index. In the 14-year period tracked (2000–2014), Koop Award winners’ stock values appreciated by 325% compared with the market average appreciation of 105%. Conclusions: This study supports prior and ongoing research demonstrating a higher market valuation—an affirmation of business success by Wall Street investors—of socially responsible companies that invest in the health and well-being of their workers when compared with other publicly traded firms. PMID:26716843

  10. A game-based crowdsourcing platform for rapidly training middle and high school students to perform biomedical image analysis

    NASA Astrophysics Data System (ADS)

    Feng, Steve; Woo, Min-jae; Kim, Hannah; Kim, Eunso; Ki, Sojung; Shao, Lei; Ozcan, Aydogan

    2016-03-01

    We developed an easy-to-use and widely accessible crowd-sourcing tool for rapidly training humans to perform biomedical image diagnostic tasks and demonstrated this platform's ability on middle and high school students in South Korea to diagnose malaria infected red-blood-cells (RBCs) using Giemsa-stained thin blood smears imaged under light microscopes. We previously used the same platform (i.e., BioGames) to crowd-source diagnostics of individual RBC images, marking them as malaria positive (infected), negative (uninfected), or questionable (insufficient information for a reliable diagnosis). Using a custom-developed statistical framework, we combined the diagnoses from both expert diagnosticians and the minimally trained human crowd to generate a gold standard library of malaria-infection labels for RBCs. Using this library of labels, we developed a web-based training and educational toolset that provides a quantified score for diagnosticians/users to compare their performance against their peers and view misdiagnosed cells. We have since demonstrated the ability of this platform to quickly train humans without prior training to reach high diagnostic accuracy as compared to expert diagnosticians. Our initial trial group of 55 middle and high school students has collectively played more than 170 hours, each demonstrating significant improvements after only 3 hours of training games, with diagnostic scores that match expert diagnosticians'. Next, through a national-scale educational outreach program in South Korea we recruited >1660 students who demonstrated a similar performance level after 5 hours of training. We plan to further demonstrate this tool's effectiveness for other diagnostic tasks involving image labeling and aim to provide an easily-accessible and quickly adaptable framework for online training of new diagnosticians.

  11. The performance of stroke survivors in turning-while-walking while carrying out a concurrent cognitive task compared with controls.

    PubMed

    Chan, Wing-Nga; Tsang, William Wai-Nam

    2017-01-01

    Turning-while-walking is one of the commonest causes of falls in stroke survivors. It involves cognitive processing and may be challenging when performed concurrently with a cognitive task. Previous studies of dual-tasking involving turning-while-walking in stroke survivors show that the performance of physical tasks is compromised. However, the design of those studies did not address the response of stroke survivors under dual-tasking condition without specifying the task-preference and its effect on the performance of the cognitive task. First, to compare the performance of single-tasking and dual-tasking in stroke survivors. Second, to compare the performance of stroke survivors with non-stroke controls. Fifty-nine stroke survivors and 45 controls were assessed with an auditory Stroop test, a turning-while-walking test, and a combination of the two single tasks. The outcome of the cognitive task was measured by the reaction time and accuracy of the task. The physical task was evaluated by measuring the turning duration, number of steps to turn, and time to complete the turning-while-walking test. Stroke survivors showed a significantly reduced accuracy in the auditory Stroop test when dual-tasking, but there was no change in the reaction time. Their performance in the turning-while-walking task was similar under both single-tasking and dual-tasking condition. Additionally, stroke survivors demonstrated a significantly longer reaction time and lower accuracy than the controls both when single-tasking and dual-tasking. They took longer to turn, with more steps, and needed more time to complete the turning-while-walking task in both tasking conditions. The results show that stroke survivors with high mobility function performed the auditory Stroop test less accurately while preserving simultaneous turning-while-walking performance. They also demonstrated poorer performance in both single-tasking and dual-tasking as compared with controls.

  12. Free Space Optical Communication Utilizing Mid-Infrared Interband Cascade Laser

    NASA Technical Reports Server (NTRS)

    Soibel, A.; Wright, M.; Farr, W.; Keo, S.; Hill, C.; Yang, R. Q.; Liu, H. C.

    2010-01-01

    A Free Space Optical (FSO) link utilizing mid-IR Interband Cascade lasers has been demonstrated in the 3-5 micron atmospheric transmission window with data rates up to 70 Mb/s and bit-error-rate (BER) less than 10 (exp -8). The performance of the mid-IR FSO link has been compared with the performance of a near-IR link under various fog conditions using an indoor communication testbed. These experiments demonstrated the lower attenuation and scintillation advantages of a mid-IR FSO link through fog than a 1550 nm FSO link.

  13. Optimization of Turbine Engine Cycle Analysis with Analytic Derivatives

    NASA Technical Reports Server (NTRS)

    Hearn, Tristan; Hendricks, Eric; Chin, Jeffrey; Gray, Justin; Moore, Kenneth T.

    2016-01-01

    A new engine cycle analysis tool, called Pycycle, was recently built using the OpenMDAO framework. This tool uses equilibrium chemistry based thermodynamics, and provides analytic derivatives. This allows for stable and efficient use of gradient-based optimization and sensitivity analysis methods on engine cycle models, without requiring the use of finite difference derivative approximation methods. To demonstrate this, a gradient-based design optimization was performed on a multi-point turbofan engine model. Results demonstrate very favorable performance compared to an optimization of an identical model using finite-difference approximated derivatives.

  14. The design and operating characteristics of an advanced 30-kW ammonia arcjet engine

    NASA Technical Reports Server (NTRS)

    Deininger, William D.; Pivirotto, Thomas J.; Brophy, John R.

    1987-01-01

    Experimental investigations were conducted to evaluate the effects of a contoured nozzle and modified cathode shape on ammonia arcjet engine performance. The contoured nozzle performance data were compared to the performance data of an arcjet which had a 38-deg included-angle, conical nozzle. Thrust improvements of up to 10 percent were demonstrated which corresponded to 3 percent improvements in specific impulse and 10 percent improvements in thrust efficiency. Performance characterizations for the modified cathode tip were conducted with the contoured nozzle arcjet. A uniform 15 percent decrease in arc voltage was demonstrated over a mass flow range of 0.175 to 0.350 g/s. A 4 percent improvement in thrust efficiency was noted at 22.0 kW.

  15. Semitransparent organic photovoltaic modules with Ag nanowire top electrodes

    NASA Astrophysics Data System (ADS)

    Guo, Fei; Kubis, Peter; Przybilla, Thomas; Spiecker, Erdmann; Forberich, Karen; Brabec, Christoph J.

    2014-10-01

    Semitransparent organic photovoltaic (OPV) cells are promising for applications in transparent architectures where their opaque counterparts are not suitable. Manufacturing of large-area modules without performance losses compared to their lab-scale devices is a key step towards practical applications of this PV technology. In this paper, we report the use of solution-processed silver nanowires as top electrodes and fabricate semitransparent OPV modules based on ultra-fast laser scribing. Through a rational choice of device architecture in combination with high-precision laser patterning, we demonstrate efficient semitransparent modules with comparable performance as compared to the reference devices.

  16. Long-Term Effects of Attentional Performance on Functional Brain Network Topology

    PubMed Central

    Breckel, Thomas P. K.; Thiel, Christiane M.; Bullmore, Edward T.; Zalesky, Andrew; Patel, Ameera X.; Giessing, Carsten

    2013-01-01

    Individuals differ in their cognitive resilience. Less resilient people demonstrate a greater tendency to vigilance decrements within sustained attention tasks. We hypothesized that a period of sustained attention is followed by prolonged changes in the organization of “resting state” brain networks and that individual differences in cognitive resilience are related to differences in post-task network reorganization. We compared the topological and spatial properties of brain networks as derived from functional MRI data (N = 20) recorded for 6 mins before and 12 mins after the performance of an attentional task. Furthermore we analysed changes in brain topology during task performance and during the switches between rest and task conditions. The cognitive resilience of each individual was quantified as the rate of increase in response latencies over the 32-minute time course of the attentional paradigm. On average, functional networks measured immediately post-task demonstrated significant and prolonged changes in network organization compared to pre-task networks with higher connectivity strength, more clustering, less efficiency, and shorter distance connections. Individual differences in cognitive resilience were significantly correlated with differences in the degree of recovery of some network parameters. Changes in network measures were still present in less resilient individuals in the second half of the post-task period (i.e. 6–12 mins after task completion), while resilient individuals already demonstrated significant reductions of functional connectivity and clustering towards pre-task levels. During task performance brain topology became more integrated with less clustering and higher global efficiency, but linearly decreased with ongoing time-on-task. We conclude that sustained attentional task performance has prolonged, “hang-over” effects on the organization of post-task resting-state brain networks; and that more cognitively resilient individuals demonstrate faster rates of network recovery following a period of attentional effort. PMID:24040185

  17. Combining performance and outcome indicators can be used in a standardized way: a pilot study of two multidisciplinary, full-scale major aircraft exercises

    PubMed Central

    2012-01-01

    Background Disaster medicine is a fairly young scientific discipline and there is a need for the development of new methods for evaluation and research. This includes full-scale disaster exercisers. A standardized concept on how to evaluate these exercises, could lead to easier identification of pitfalls caused by system-errors in the organization. The aim of this study was to demonstrate the feasibility of using a combination of performance and outcome indicators so that results can be compared in standardized full-scale exercises. Methods Two multidisciplinary, full-scale exercises were studied in 2008 and 2010. The panorama had the same setup. Sets of performance indicators combined with indicators for unfavorable patient outcome were recorded in predesigned templates. Evaluators, all trained in a standardized way at a national disaster medicine centre, scored the results on predetermined locations; at the scene, at hospital and at the regional command and control. Results All data regarding the performance indicators of the participants during the exercises were obtained as well as all data regarding indicators for patient outcome. Both exercises could therefore be compared regarding performance (processes) as well as outcome indicators. The data from the performance indicators during the exercises showed higher scores for the prehospital command in the second exercise 15 points and 3 points respectively. Results from the outcome indicators, patient survival and patient complications, demonstrated a higher number of preventable deaths and a lower number of preventable complications in the exercise 2010. In the exercise 2008 the number of preventable deaths was lower and the number of preventable complications was higher. Conclusions Standardized multidisciplinary, full-scale exercises in different settings can be conducted and evaluated with performance indicators combined with outcome indicators enabling results from exercises to be compared. If exercises are performed in a standardized way, results may serve as a basis for lessons learned. Future use of the same concept using the combination of performance indicators and patient outcome indicators may demonstrate new and important evidence that could lead to new and better knowledge that also may be applied during real incidents. PMID:22929479

  18. Combining performance and outcome indicators can be used in a standardized way: a pilot study of two multidisciplinary, full-scale major aircraft exercises.

    PubMed

    Rådestad, Monica; Nilsson, Heléne; Castrén, Maaret; Svensson, Leif; Rüter, Anders; Gryth, Dan

    2012-08-28

    Disaster medicine is a fairly young scientific discipline and there is a need for the development of new methods for evaluation and research. This includes full-scale disaster exercisers. A standardized concept on how to evaluate these exercises, could lead to easier identification of pitfalls caused by system-errors in the organization. The aim of this study was to demonstrate the feasibility of using a combination of performance and outcome indicators so that results can be compared in standardized full-scale exercises. Two multidisciplinary, full-scale exercises were studied in 2008 and 2010. The panorama had the same setup. Sets of performance indicators combined with indicators for unfavorable patient outcome were recorded in predesigned templates. Evaluators, all trained in a standardized way at a national disaster medicine centre, scored the results on predetermined locations; at the scene, at hospital and at the regional command and control. All data regarding the performance indicators of the participants during the exercises were obtained as well as all data regarding indicators for patient outcome. Both exercises could therefore be compared regarding performance (processes) as well as outcome indicators. The data from the performance indicators during the exercises showed higher scores for the prehospital command in the second exercise 15 points and 3 points respectively. Results from the outcome indicators, patient survival and patient complications, demonstrated a higher number of preventable deaths and a lower number of preventable complications in the exercise 2010. In the exercise 2008 the number of preventable deaths was lower and the number of preventable complications was higher. Standardized multidisciplinary, full-scale exercises in different settings can be conducted and evaluated with performance indicators combined with outcome indicators enabling results from exercises to be compared. If exercises are performed in a standardized way, results may serve as a basis for lessons learned. Future use of the same concept using the combination of performance indicators and patient outcome indicators may demonstrate new and important evidence that could lead to new and better knowledge that also may be applied during real incidents.

  19. Comparison of trunk kinematics in trunk training exercises and throwing.

    PubMed

    Stodden, David F; Campbell, Brian M; Moyer, Todd M

    2008-01-01

    Strength and conditioning professionals, as well as coaches, have emphasized the importance of training the trunk and the benefits it may have on sport performance and reducing the potential for injury. However, no data on the efficacy of trunk training support such claims. The purpose of this study was to examine the maximum differential trunk rotation and maximum angular velocities of the pelvis and upper torso of participants while they performed 4 trunk exercises (seated band rotations, cross-overs, medicine ball throws, and twisters) and compare these trunk exercise kinematics with the trunk kinematics demonstrated in actual throwing performance. Nine NCAA Division I baseball players participated in this study. Each participant's trunk kinematics was analyzed while he performed 5 repetitions of each exercise in both dominant and nondominant rotational directions. Results indicated maximum differentiated rotation in all 4 trunk exercises was similar to maximum differentiated rotation (approximately 50-60 degrees) demonstrated in throwing performance. Maximum angular velocities of the pelvis and upper torso in the trunk exercises were appreciably slower (approximately 50% or less) than the angular velocities demonstrated during throwing performance. Incorporating trunk training exercises that demonstrate sufficient trunk ranges of motion and velocities into a strength and conditioning program may help to increase ball velocity and/or decrease the risk injury.

  20. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    EPA Pesticide Factsheets

    The EnSys Petro Test System developed by Strategic Diagnostics Inc. (SDI), was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the EnSys Petro Test System and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in four areas contaminated with gasoline, diesel, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  1. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    EPA Pesticide Factsheets

    The Synchronous Scanning Luminoscope (Luminoscope) developed by the Oak Ridge National Laboratory in collaboration with Environmental Systems Corporation (ESC) was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the Luminoscope and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in five areas contaminated with gasoline, diesel, lubricating oil, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  2. Educational Implications of Expertise Reversal Effects in Learning and Performance of Complex Cognitive and Sensorimotor Skills

    ERIC Educational Resources Information Center

    Kalyuga, Slava; Rikers, Remy; Paas, Fred

    2012-01-01

    There have been several rather counterintuitive phenomena observed in different fields of research that compared the performance of experts and novices. For example, studies of medical expertise demonstrated that less experienced medical students may in some situations outperform seasoned medical practitioners on recall of specific cases. Studies…

  3. The Development of MST Test Information for the Prediction of Test Performances

    ERIC Educational Resources Information Center

    Park, Ryoungsun; Kim, Jiseon; Chung, Hyewon; Dodd, Barbara G.

    2017-01-01

    The current study proposes novel methods to predict multistage testing (MST) performance without conducting simulations. This method, called MST test information, is based on analytic derivation of standard errors of ability estimates across theta levels. We compared standard errors derived analytically to the simulation results to demonstrate the…

  4. Comparing and contrasting poverty reduction performance of social welfare programs across jurisdictions in Canada using Data Envelopment Analysis (DEA): an exploratory study of the era of devolution.

    PubMed

    Habibov, Nazim N; Fan, Lida

    2010-11-01

    In the mid-1990s, the responsibilities to design, implement, and evaluate social welfare programs were transferred from federal to local jurisdictions in many countries of North America and Europe through devolution processes. Devolution has caused the need for a technique to measure and compare the performances of social welfare programs across multiple jurisdictions. This paper utilizes Data Envelopment Analysis (DEA) for a comparison of poverty reduction performances of jurisdictional social welfare programs across Canadian provinces. From the theoretical perspective, findings of this paper demonstrates that DEA is a promising method to evaluate, compare, and benchmark poverty reduction performance across multiple jurisdictions using multiple inputs and outputs. This paper demonstrates that DEA generates easy to comprehend composite rankings of provincial performances, identifies appropriate benchmarks for each inefficient province, and estimates sources and amounts of improvement needed to make the provinces efficient. From a practical perspective the empirical results presented in this paper indicate that Newfoundland, Prince Edwards Island, and Alberta achieve better efficiency in poverty reduction than other provinces. Policy makers and social administrators of the ineffective provinces across Canada may find benefit in selecting one of the effective provinces as a benchmark for improving their own performance based on similar size and structure of population, size of the budget for social programs, and traditions with administering particular types of social programs. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  5. Depressed left ventricular performance. Response to volume infusion in patients with sepsis and septic shock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ognibene, F.P.; Parker, M.M.; Natanson, C.

    Volume infusion, to increase preload and to enhance ventricular performance, is accepted as initial management of septic shock. Recent evidence has demonstrated depressed myocardial function in human septic shock. We analyzed left ventricular performance during volume infusion using serial data from simultaneously obtained pulmonary artery catheter hemodynamic measurements and radionuclide cineangiography. Critically ill control subjects (n = 14), patients with sepsis but without shock (n = 21), and patients with septic shock (n = 21) had prevolume infusion hemodynamic measurements determined and received statistically similar volumes of fluid resulting in similar increases in pulmonary capillary wedge pressure. There was amore » strong trend (p = 0.004) toward less of a change in left ventricular stroke work index (LVSWI) after volume infusion in patients with sepsis and septic shock compared with control subjects. The LVSWI response after volume infusion was significantly less in patients with septic shock when compared with critically ill control subjects (p less than 0.05). These data demonstrate significantly altered ventricular performance, as measured by LVSWI, in response to volume infusion in patients with septic shock.« less

  6. Inactivation of Smad5 in Endothelial Cells and Smooth Muscle Cells Demonstrates that Smad5 Is Required for Cardiac Homeostasis

    PubMed Central

    Umans, Lieve; Cox, Luk; Tjwa, Marc; Bito, Virginie; Vermeire, Liesbeth; Laperre, Kjell; Sipido, Karin; Moons, Lieve; Huylebroeck, Danny; Zwijsen, An

    2007-01-01

    Smads are intracellular signaling proteins that transduce signals elicited by members of the transforming growth factor (TGF)-β superfamily. Smad5 and Smad1 are highly homologous, and they mediate primarily bone morphogenetic protein (Bmp) signals. We used the Cre-loxP system and Sm22-Cre and Tie-1-Cre mice to study the function of Smad5 in the developing blood vessel wall. Analysis of embryos demonstrated that deletion of Smad5 in endothelial or smooth muscle cells resulted in a normal organization of embryonic and extra-embryonic vasculature. Angiogenic assays performed in adult mice revealed that mutant mice display a comparable angiogenic and vascular remodeling response to control mice. In Sm22-Cre;Smad5fl/− mice, Smad5 is also deleted in cardiomyocytes. Echocardiographic analysis on those 9-month-old female mice demonstrated larger left ventricle internal diameters and decreased fractional shortening compared with control littermates without signs of cardiac hypertrophy. The decreased cardiac contractility was associated with a decreased performance in a treadmill experiment. In isolated cardiomyocytes, fractional shortening was significantly reduced compared with control cells. These data demonstrate that restricted deletion of Smad5 in the blood vessel wall results in viable mice. However, loss of Smad5 in cardiomyocytes leads to a mild heart defect. PMID:17456754

  7. Inactivation of Smad5 in endothelial cells and smooth muscle cells demonstrates that Smad5 is required for cardiac homeostasis.

    PubMed

    Umans, Lieve; Cox, Luk; Tjwa, Marc; Bito, Virginie; Vermeire, Liesbeth; Laperre, Kjell; Sipido, Karin; Moons, Lieve; Huylebroeck, Danny; Zwijsen, An

    2007-05-01

    Smads are intracellular signaling proteins that transduce signals elicited by members of the transforming growth factor (TGF)-beta superfamily. Smad5 and Smad1 are highly homologous, and they mediate primarily bone morphogenetic protein (Bmp) signals. We used the Cre-loxP system and Sm22-Cre and Tie-1-Cre mice to study the function of Smad5 in the developing blood vessel wall. Analysis of embryos demonstrated that deletion of Smad5 in endothelial or smooth muscle cells resulted in a normal organization of embryonic and extra-embryonic vasculature. Angiogenic assays performed in adult mice revealed that mutant mice display a comparable angiogenic and vascular remodeling response to control mice. In Sm22-Cre; Smad5(fl/-) mice, Smad5 is also deleted in cardiomyocytes. Echocardiographic analysis on those 9-month-old female mice demonstrated larger left ventricle internal diameters and decreased fractional shortening compared with control littermates without signs of cardiac hypertrophy. The decreased cardiac contractility was associated with a decreased performance in a treadmill experiment. In isolated cardiomyocytes, fractional shortening was significantly reduced compared with control cells. These data demonstrate that restricted deletion of Smad5 in the blood vessel wall results in viable mice. However, loss of Smad5 in cardiomyocytes leads to a mild heart defect.

  8. A Computer-Adaptive Disability Instrument for Lower Extremity Osteoarthritis Research Demonstrated Promising Breadth, Precision and Reliability

    PubMed Central

    Jette, Alan M.; McDonough, Christine M.; Haley, Stephen M.; Ni, Pengsheng; Olarsch, Sippy; Latham, Nancy; Hambleton, Ronald K.; Felson, David; Kim, Young-jo; Hunter, David

    2012-01-01

    Objective To develop and evaluate a prototype measure (OA-DISABILITY-CAT) for osteoarthritis research using Item Response Theory (IRT) and Computer Adaptive Test (CAT) methodologies. Study Design and Setting We constructed an item bank consisting of 33 activities commonly affected by lower extremity (LE) osteoarthritis. A sample of 323 adults with LE osteoarthritis reported their degree of limitation in performing everyday activities and completed the Health Assessment Questionnaire-II (HAQ-II). We used confirmatory factor analyses to assess scale unidimensionality and IRT methods to calibrate the items and examine the fit of the data. Using CAT simulation analyses, we examined the performance of OA-DISABILITY-CATs of different lengths compared to the full item bank and the HAQ-II. Results One distinct disability domain was identified. The 10-item OA-DISABILITY-CAT demonstrated a high degree of accuracy compared with the full item bank (r=0.99). The item bank and the HAQ-II scales covered a similar estimated scoring range. In terms of reliability, 95% of OA-DISABILITY reliability estimates were over 0.83 versus 0.60 for the HAQ-II. Except at the highest scores the 10-item OA-DISABILITY-CAT demonstrated superior precision to the HAQ-II. Conclusion The prototype OA-DISABILITY-CAT demonstrated promising measurement properties compared to the HAQ-II, and is recommended for use in LE osteoarthritis research. PMID:19216052

  9. Transition to motherhood and the self: measurement, stability, and change.

    PubMed

    Ruble, D N; Brooks-Gunn, J; Fleming, A S; Fitzmaurice, G; Stangor, C; Deutsch, F

    1990-03-01

    Different ways of conceptualizing and measuring change in attitudes during transition to motherhood are examined. A series of analyses was performed on data from a cross-sectional sample (N = 667) and a smaller longitudinal sample (n = 48) to demonstrate sound psychometric properties for 2 new scales and to show construct comparability across different phases of childbearing. For Childbearing Attitudes Questionnaire, results demonstrated equality of covariance for 16 scales and comparability of structure and meaning of 4 higher order factors--identification with motherhood, social orientation, self-confidence, and negative aspects of giving birth. For Mothering Self-Definition Questionnaire, results demonstrated equality of covariance of 5 scales and comparability of structure and meaning of a single higher order factor, interpreted as reflecting positive feelings about one's mothering characteristics. Analyses of correlations and mean differences identified areas of change and stability.

  10. Laparoscopic-guided abdominal wall nerve blocks in the pediatric population: a novel technique with comparison to ultrasound-guided blocks and local wound infiltration alone.

    PubMed

    Landmann, Alessandra; Visoiu, Mihaela; Malek, Marcus M

    2018-03-01

    Abdominal wall nerve blocks have been gaining popularity for the treatment of perioperative pain in children. Our aim was to compare a technique of surgeon-performed, laparoscopic abdominal wall nerve blocks to anesthesia-placed, ultrasound-guided abdominal wall nerve blocks and the current standard of local wound infiltration. After institutional review board approval was obtained, a retrospective chart review was performed of pediatric patients treated at a single institution during a 2-year period. Statistics were calculated using analysis of variance with post-hoc Bonferonni t tests for pair-wise comparisons. Included in this study were 380 patients who received ultrasound-guided abdominal wall nerve blocks (n = 125), laparoscopic-guided abdominal wall nerve blocks (n = 88), and local wound infiltration (n = 117). Groups were well matched for age, sex, and weight. There was no significant difference in pain scores within the first 8 hours or narcotic usage between groups. Local wound infiltration demonstrated the shortest overall time required to perform (P < .0001). Patients who received a surgeon-performed abdominal wall nerve block demonstrated a shorter duration of hospital stay when compared to the other groups (P = .02). Our study has demonstrated that laparoscopic-guided abdominal wall nerve blocks show similar efficacy to ultrasound-guided nerve blocks performed by pain management physicians without increasing time in the operating room. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. A Systematic Review of Longitudinal Studies of Mathematics Difficulty.

    PubMed

    Nelson, Gena; Powell, Sarah R

    2017-06-01

    Some students may be diagnosed with a learning disability in mathematics or dyscalculia, whereas other students may demonstrate below-grade-level mathematics performance without a disability diagnosis. In the literature, researchers often identify students in both groups as experiencing math difficulty. To understand the performance of students with math difficulty, we examined 35 studies that reported longitudinal results of mathematics achievement (i.e., mathematics performance measured across at least a 12-month span). Our primary goal was to conduct a systematic review of these studies and to understand whether the growth of students with math difficulty was comparable or stagnant when compared with that of students without math difficulty. We also analyzed whether identification of math difficulty was predictive of mathematics achievement in later grades and whether a diagnosis of math difficulty was stable across grade levels. Results indicate that students with math difficulty demonstrate growth on mathematics measures, but this growth still leads to lower performance than that of students without math difficulty. Identification of math difficulty is strongly related to math performance in subsequent grades, and this diagnosis is often stable. Collectively, this literature indicates that students with math difficulty continue to struggle with mathematics in later grades.

  12. A Comparative Analysis of Learning Styles and Teaching Styles of Mathematics Students and Instructors.

    ERIC Educational Resources Information Center

    Raines, Roy H.

    Mathematics students at the community college level have continually experienced a relatively low achievement rate when compared to their performance in other subjects. Most of the instructional strategies encountered by these students consist of the lecture-discussion-demonstration format, with no allowances made for individual difference except…

  13. Experimental comparison of MCFC performance using three different biogas types and methane

    NASA Astrophysics Data System (ADS)

    Bove, Roberto; Lunghi, Piero

    Biogas recovery is an environmentally friendly and cost-effective practice that is getting consensus in both the scientific and industrial community, as the growing number of projects demonstrate. The use of fuel cells as energy conversion systems increases the conversion efficiency, as well as the environmental benefits. Molten carbonate fuel cells (MCFC) operate at a temperature of about 650 °C, thus presenting a high fuel flexibility, compared to low temperature fuel cells. Aim of the present study is to compare the performance of an MCFC single cell, fuelled with different biogas types as well as methane. The biogases considered are derived from the following processes: (1) steam gasification in an entrained flow gasifier; (2) steam gasification in a duel interconnect fluidized bed gasifier; (3) biogas from an anaerobic digestion process. The performances are evaluated for different fuel utilization and current densities. The results are an essential starting point for a complete system design and demonstration.

  14. Improved GaSb-based quantum well laser performance through metamorphic growth on GaAs substrates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, Christopher J. K., E-mail: richardson@lps.umd.edu; He, Lei; Apiratikul, Paveen

    The promise of the metamorphic growth paradigm is to enable design freedom of the substrate selection criteria beyond current choices that are limited by lattice matching requirements. A demonstration of this emerging degree of freedom is reported here by directly comparing identical laser structures grown both pseudomorphically on a GaSb substrate and metamorphically on a GaAs substrate. Improved thermal performance of the metamorphic laser material enables a higher output power before thermal roll-over begins. These performance gains are demonstrated in minimally processed gain-guided broad-area type-I lasers emitting close to 2-μm wavelengths and mounted p-side up. Continuous wave measurements at roommore » temperature yield a T{sub 0} of 145 K and peak output power of 192 mW from metamorphic lasers, compared to a T{sub 0} of 96 K and peak output power of 164 mW from identical lasers grown pseudomorphically on GaSb.« less

  15. Performance evaluation of 2D and 3D deep learning approaches for automatic segmentation of multiple organs on CT images

    NASA Astrophysics Data System (ADS)

    Zhou, Xiangrong; Yamada, Kazuma; Kojima, Takuya; Takayama, Ryosuke; Wang, Song; Zhou, Xinxin; Hara, Takeshi; Fujita, Hiroshi

    2018-02-01

    The purpose of this study is to evaluate and compare the performance of modern deep learning techniques for automatically recognizing and segmenting multiple organ regions on 3D CT images. CT image segmentation is one of the important task in medical image analysis and is still very challenging. Deep learning approaches have demonstrated the capability of scene recognition and semantic segmentation on nature images and have been used to address segmentation problems of medical images. Although several works showed promising results of CT image segmentation by using deep learning approaches, there is no comprehensive evaluation of segmentation performance of the deep learning on segmenting multiple organs on different portions of CT scans. In this paper, we evaluated and compared the segmentation performance of two different deep learning approaches that used 2D- and 3D deep convolutional neural networks (CNN) without- and with a pre-processing step. A conventional approach that presents the state-of-the-art performance of CT image segmentation without deep learning was also used for comparison. A dataset that includes 240 CT images scanned on different portions of human bodies was used for performance evaluation. The maximum number of 17 types of organ regions in each CT scan were segmented automatically and compared to the human annotations by using ratio of intersection over union (IU) as the criterion. The experimental results demonstrated the IUs of the segmentation results had a mean value of 79% and 67% by averaging 17 types of organs that segmented by a 3D- and 2D deep CNN, respectively. All the results of the deep learning approaches showed a better accuracy and robustness than the conventional segmentation method that used probabilistic atlas and graph-cut methods. The effectiveness and the usefulness of deep learning approaches were demonstrated for solving multiple organs segmentation problem on 3D CT images.

  16. A comparative evaluation of the chelators H4octapa and CHX-A″-DTPA with the therapeutic radiometal (90)Y.

    PubMed

    Price, Eric W; Edwards, Kimberly J; Carnazza, Kathryn E; Carlin, Sean D; Zeglis, Brian M; Adam, Michael J; Orvig, Chris; Lewis, Jason S

    2016-09-01

    To compare the radiolabeling performance, stability, and practical efficacy of the chelators CHX-A″-DTPA and H4octapa with the therapeutic radiometal (90)Y. The bifunctional chelators p-SCN-Bn-H4octapa and p-SCN-Bn-CHX-A″-DTPA were conjugated to the HER2-targeting antibody trastuzumab. The resulting immunoconjugates were radiolabeled with (90)Y to compare radiolabeling efficiency, in vitro and in vivo stability, and in vivo performance in a murine model of ovarian cancer. High radiochemical yields (>95%) were obtained with (90)Y-CHX-A″-DTPA-trastuzumab and (90)Y-octapa-trastuzumab after 15min at room temperature. Both (90)Y-CHX-A″-DTPA-trastuzumab and (90)Y-octapa-trastuzumab exhibited excellent in vitro and in vivo stability. Furthermore, the radioimmunoconjugates displayed high tumoral uptake values (42.3±4.0%ID/g for (90)Y-CHX-A″-DTPA-trastuzumab and 30.1±7.4%ID/g for (90)Y-octapa-trastuzumab at 72h post-injection) in mice bearing HER2-expressing SKOV3 ovarian cancer xenografts. Finally, (90)Y radioimmunotherapy studies performed in tumor-bearing mice demonstrated that (90)Y-CHX-A″-DTPA-trastuzumab and (90)Y-octapa-trastuzumab are equally effective therapeutic agents, as treatment with both radioimmunoconjugates yielded substantially decreased tumor growth compared to controls. Ultimately, this work demonstrates that the acyclic chelators CHX-A″-DTPA and H4octapa have comparable radiolabeling, stability, and in vivo performance, making them both suitable choices for applications requiring (90)Y. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. A randomized trial comparing didactics, demonstration, and simulation for teaching teamwork to medical residents.

    PubMed

    Semler, Matthew W; Keriwala, Raj D; Clune, Jennifer K; Rice, Todd W; Pugh, Meredith E; Wheeler, Arthur P; Miller, Alison N; Banerjee, Arna; Terhune, Kyla; Bastarache, Julie A

    2015-04-01

    Effective teamwork is fundamental to the management of medical emergencies, and yet the best method to teach teamwork skills to trainees remains unknown. In a cohort of incoming internal medicine interns, we tested the hypothesis that expert demonstration of teamwork principles and participation in high-fidelity simulation would each result in objectively assessed teamwork behavior superior to traditional didactics. This was a randomized, controlled, parallel-group trial comparing three teamwork teaching modalities for incoming internal medicine interns. Participants in a single-day orientation at the Vanderbilt University Center for Experiential Learning and Assessment were randomized 1:1:1 to didactic, demonstration-based, or simulation-based instruction and then evaluated in their management of a simulated crisis by five independent, blinded observers using the Teamwork Behavioral Rater score. Clinical performance was assessed using the American Heart Association Advanced Cardiac Life Support algorithm and a novel "Recognize, Respond, Reassess" score. Participants randomized to didactics (n = 18), demonstration (n = 17), and simulation (n = 17) were similar at baseline. The primary outcome of average overall Teamwork Behavioral Rater score for those who received demonstration-based training was similar to simulation participation (4.40 ± 1.15 vs. 4.10 ± 0.95, P = 0.917) and significantly higher than didactic instruction (4.40 ± 1.15 vs. 3.10 ± 0.51, P = 0.045). Clinical performance scores were similar between the three groups and correlated only weakly with teamwork behavior (coefficient of determination [Rs(2)] = 0.267, P < 0.001). Among incoming internal medicine interns, teamwork training by expert demonstration resulted in similar teamwork behavior to participation in high-fidelity simulation and was more effective than traditional didactics. Clinical performance was largely independent of teamwork behavior and did not differ between training modalities.

  18. Good social skills despite poor theory of mind: exploring compensation in autism spectrum disorder.

    PubMed

    Livingston, Lucy Anne; Colvert, Emma; Bolton, Patrick; Happé, Francesca

    2018-03-26

    It is proposed that some individuals with Autism Spectrum Disorder (ASD) can 'compensate' for their underlying difficulties (e.g. in theory of mind; ToM), thus demonstrating relatively few behavioural symptoms, despite continued core cognitive deficits. The mechanisms underpinning compensation are largely unexplored, as is its potential impact on mental health. This study aimed to estimate compensation patterns in ASD, by contrasting overt social behaviour with ToM task performance, in order to compare the characteristics of 'Low' and 'High' Compensators. A total of 136 autistic adolescents, from the ongoing Social Relationships Study, completed a range of cognitive tasks, the Autistic Diagnostic Observation Schedule (ADOS) and a self-report anxiety questionnaire. Participants were assigned compensation group status; High Compensators demonstrated good ADOS scores despite poor ToM performance, while Low Compensators demonstrated similarly poor ToM, accompanied by poor ADOS scores. High Compensators demonstrated better IQ and executive function (EF), but greater self-reported anxiety, compared with Low Compensators. Such differences were not found when comparing individuals who had good versus poor ADOS scores, when ToM performance was good. Other core autistic characteristics (weak central coherence, nonsocial symptoms) did not differentiate the High and Low Compensators. IQ, EF and anxiety appear to be implicated in the processes by which certain autistic young people can compensate for their underlying ToM difficulties. This tendency to compensate does not appear to reflect the severity of 'hit' for ASD per se, suggesting that well-compensated individuals are not experiencing a milder form of ASD. The construct of compensation in ASD has implications for research and clinical practice. © 2018 The Authors. Journal of Child Psychology and Psychiatry published by John Wiley & Sons Ltd on behalf of Association for Child and Adolescent Mental Health.

  19. Demonstration of differential phase-shift keying demodulation at 10 Gbit/s optimal fiber Bragg grating filters.

    PubMed

    Gatti, Davide; Galzerano, Gianluca; Laporta, Paolo; Longhi, Stefano; Janner, Davide; Guglierame, Andrea; Belmonte, Michele

    2008-07-01

    Optimal demodulation of differential phase-shift keying signals at 10 Gbit/s is experimentally demonstrated using a specially designed structured fiber Bragg grating composed by Fabry-Perot coupled cavities. Bit-error-rate measurements show that, as compared with a conventional Gaussian-shaped filter, our demodulator gives approximately 2.8 dB performance improvement.

  20. HEMISPHERIC CENTER FOR ENVIRONMENTAL TECHNOLOGY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M.A. Ebadian

    1999-09-30

    The Princeton Plasma Physics Laboratory (PPPL) demonstration of the diamond wire cutting technology on the surrogate of the Tokamak Fusion Test Reactor (TFTR), Figure 1, was performed from August 23-September 3, 1999. The plated diamond wire, Figure 2, was successful in cutting through all components of the TFTR surrogate including stainless steel, inconel and graphite. The demonstration tested three different void fill materials (mortar with sand, Rheocell-15, and foam) and three cooling systems (water, air, and liquid nitrogen). The optimum combination was determined to be the use of the low-density concrete void fill, Rheocell-15 with an average density of 52more » lbs/ft{sup 3}, using a water coolant. However, the liquid nitrogen performed better than expected with only minor problems and was considered to be a successful demonstration of the Bluegrass Concrete Cutting, Inc. proprietary liquid-nitrogen coolant system. Data from the demonstration is being calculated and a summary of the technology demonstration will be included in the October monthly report. An ITSR will be written comparing the diamond wire saw to the plasma arc (baseline) technology. The MTR Chemical Protective Suit, a proprietary new suit from Kimberly Clark, was evaluated from 8/9/99 to 8/12/99 at Beaver, WV. This particular suit was tested on subjects performing three different tasks: climbing through a horizontal confined space, vertical confined space (pit), and loading and unloading material using a wheel barrow. Multiple test subjects performed each task for 20 minutes each. Performance of the innovative suit was compared to two commonly used types of protective clothing. Vital statistics, including body temperature and heart rate, were continuously monitored and recorded by an authorized physician. A summary of the demonstration will be included in the October monthly report. Along with the MTR Chemical Protective Suit, the VitalSense{trademark} Telemetric Monitoring System from Mini Mitter Co., Inc. was evaluated. A summary of the demonstration will be included in the October monthly report. A Kool-Vest from MicroClimate Systems, Inc. was evaluated during assessment at Beaver, WV from 8/16/99 to 8/17/99. The evaluation was performed in the same manner as the MTR Chemical Protective Suit described above. A summary of the demonstration will be included in the October monthly report. A brochure announcing the new Gateway to Environmental Technology (GET) website was produced by FIU-HCET and is being distributed to the D&D community by FETC-DDFA. The website provides links to the TIS and other decision support systems developed at FIU-HCET.« less

  1. Comparative performances of eggs and embryos of sea urchin (Paracentrotus lividus) in toxicity bioassays used for assessment of marine sediment quality.

    PubMed

    Khosrovyan, A; Rodríguez-Romero, A; Salamanca, M J; Del Valls, T A; Riba, I; Serrano, F

    2013-05-15

    The potential toxicity of sediments from various ports was assessed by means of two different liquid-phase toxicity bioassays (acute and chronic) with embryos and eggs of sea urchin Paracentrotus lividus. Performances of embryos and eggs of P. lividus in these bioassays were compared for their interchangeable applicability in integrated sediment quality assessment. The obtained endpoints (percentages of normally developed plutei and fertilized eggs) were linked to physical and chemical properties of sediments and demonstrated dependence on sediment contamination. The endpoints in the two bioassays were strongly correlated and generally exhibited similar tendency throughout the samples. Therein, embryos demonstrated higher sensitivity to elutriate exposure, compared to eggs. It was concluded that these tests could be used interchangeably for testing toxicity of marine sediments. Preferential use of any of the bioassays can be determined by the discriminatory capacity of the test or vulnerability consideration of the test subject to the surrounding conditions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Testing Measurement Invariance across Groups of Children with and without Attention-Deficit/ Hyperactivity Disorder: Applications for Word Recognition and Spelling Tasks

    PubMed Central

    Lúcio, Patrícia S.; Salum, Giovanni; Swardfager, Walter; Mari, Jair de Jesus; Pan, Pedro M.; Bressan, Rodrigo A.; Gadelha, Ary; Rohde, Luis A.; Cogo-Moreira, Hugo

    2017-01-01

    Although studies have consistently demonstrated that children with attention-deficit/hyperactivity disorder (ADHD) perform significantly lower than controls on word recognition and spelling tests, such studies rely on the assumption that those groups are comparable in these measures. This study investigates comparability of word recognition and spelling tests based on diagnostic status for ADHD through measurement invariance methods. The participants (n = 1,935; 47% female; 11% ADHD) were children aged 6–15 with normal IQ (≥70). Measurement invariance was investigated through Confirmatory Factor Analysis and Multiple Indicators Multiple Causes models. Measurement invariance was attested in both methods, demonstrating the direct comparability of the groups. Children with ADHD were 0.51 SD lower in word recognition and 0.33 SD lower in spelling tests than controls. Results suggest that differences in performance on word recognition and spelling tests are related to true mean differences based on ADHD diagnostic status. Implications for clinical practice and research are discussed. PMID:29118733

  3. Testing Measurement Invariance across Groups of Children with and without Attention-Deficit/ Hyperactivity Disorder: Applications for Word Recognition and Spelling Tasks.

    PubMed

    Lúcio, Patrícia S; Salum, Giovanni; Swardfager, Walter; Mari, Jair de Jesus; Pan, Pedro M; Bressan, Rodrigo A; Gadelha, Ary; Rohde, Luis A; Cogo-Moreira, Hugo

    2017-01-01

    Although studies have consistently demonstrated that children with attention-deficit/hyperactivity disorder (ADHD) perform significantly lower than controls on word recognition and spelling tests, such studies rely on the assumption that those groups are comparable in these measures. This study investigates comparability of word recognition and spelling tests based on diagnostic status for ADHD through measurement invariance methods. The participants ( n = 1,935; 47% female; 11% ADHD) were children aged 6-15 with normal IQ (≥70). Measurement invariance was investigated through Confirmatory Factor Analysis and Multiple Indicators Multiple Causes models. Measurement invariance was attested in both methods, demonstrating the direct comparability of the groups. Children with ADHD were 0.51 SD lower in word recognition and 0.33 SD lower in spelling tests than controls. Results suggest that differences in performance on word recognition and spelling tests are related to true mean differences based on ADHD diagnostic status. Implications for clinical practice and research are discussed.

  4. Demonstration of EnergyNest thermal energy storage (TES) technology

    NASA Astrophysics Data System (ADS)

    Hoivik, Nils; Greiner, Christopher; Tirado, Eva Bellido; Barragan, Juan; Bergan, Pâl; Skeie, Geir; Blanco, Pablo; Calvet, Nicolas

    2017-06-01

    This paper presents the experimental results from the EnergyNest 2 × 500 kWhth thermal energy storage (TES) pilot system installed at Masdar Institute of Science & Technology Solar Platform. Measured data are shown and compared to simulations using a specially developed computer program to verify the stability and performance of the TES. The TES is based on a solid-state concrete storage medium (HEATCRETE®) with integrated steel tube heat exchangers cast into the concrete. The unique concrete recipe used in the TES has been developed in collaboration with Heidelberg Cement; this material has significantly higher thermal conductivity compared to regular concrete implying very effective heat transfer, at the same time being chemically stable up to 450 °C. The demonstrated and measured performance of the TES matches the predictions based on simulations, and proves the operational feasibility of the EnergyNest concrete-based TES. A further case study is analyzed where a large-scale TES system presented in this article is compared to two-tank indirect molten salt technology.

  5. Parametric and experimental analysis using a power flow approach

    NASA Technical Reports Server (NTRS)

    Cuschieri, J. M.

    1988-01-01

    Having defined and developed a structural power flow approach for the analysis of structure-borne transmission of structural vibrations, the technique is used to perform an analysis of the influence of structural parameters on the transmitted energy. As a base for comparison, the parametric analysis is first performed using a Statistical Energy Analysis approach and the results compared with those obtained using the power flow approach. The advantages of using structural power flow are thus demonstrated by comparing the type of results obtained by the two methods. Additionally, to demonstrate the advantages of using the power flow method and to show that the power flow results represent a direct physical parameter that can be measured on a typical structure, an experimental investigation of structural power flow is also presented. Results are presented for an L-shaped beam for which an analytical solution has already been obtained. Furthermore, the various methods available to measure vibrational power flow are compared to investigate the advantages and disadvantages of each method.

  6. Acute, low-dose methamphetamine administration improves attention/information processing speed and working memory in methamphetamine-dependent individuals displaying poorer cognitive performance at baseline.

    PubMed

    Mahoney, James J; Jackson, Brian J; Kalechstein, Ari D; De La Garza, Richard; Newton, Thomas F

    2011-03-30

    Abstinent methamphetamine (Meth) dependent individuals demonstrate poorer performance on tests sensitive to attention/information processing speed, learning and memory, and working memory when compared to non-Meth dependent individuals. The poorer performance on these tests may contribute to the morbidity associated with Meth-dependence. In light of this, we sought to determine the effects of acute, low-dose Meth administration on attention, working memory, and verbal learning and memory in 19 non-treatment seeking, Meth-dependent individuals. Participants were predominantly male (89%), Caucasian (63%), and cigarette smokers (63%). Following a four day, drug-free washout period, participants were given a single-blind intravenous infusion of saline, followed the next day by 30 mg of Meth. A battery of neurocognitive tasks was administered before and after each infusion, and performance on measures of accuracy and reaction time were compared between conditions. While acute Meth exposure did not affect test performance for the entire sample, participants who demonstrated relatively poor performance on these tests at baseline, identified using a median split on each test, showed significant improvement on measures of attention/information processing speed and working memory when administered Meth. Improved performance was seen on the following measures of working memory: choice reaction time task (p≤0.04), a 1-back task (p≤0.01), and a 2-back task (p≤0.04). In addition, those participants demonstrating high neurocognitive performance at baseline experienced similar or decreased performance following Meth exposure. These findings suggest that acute administration of Meth may temporarily improve Meth-associated neurocognitive performance in those individuals experiencing lower cognitive performance at baseline. As a result, stimulants may serve as a successful treatment for improving cognitive functioning in those Meth-dependent individuals experiencing neurocognitive impairment. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Investigating Neuroanatomical Features in Top Athletes at the Single Subject Level.

    PubMed

    Taubert, Marco; Wenzel, Uwe; Draganski, Bogdan; Kiebel, Stefan J; Ragert, Patrick; Krug, Jürgen; Villringer, Arno

    2015-01-01

    In sport events like Olympic Games or World Championships competitive athletes keep pushing the boundaries of human performance. Compared to team sports, high achievements in many athletic disciplines depend solely on the individual's performance. Contrasting previous research looking for expertise-related differences in brain anatomy at the group level, we aim to demonstrate changes in individual top athlete's brain, which would be averaged out in a group analysis. We compared structural magnetic resonance images (MRI) of three professional track-and-field athletes to age-, gender- and education-matched control subjects. To determine brain features specific to these top athletes, we tested for significant deviations in structural grey matter density between each of the three top athletes and a carefully matched control sample. While total brain volumes were comparable between athletes and controls, we show regional grey matter differences in striatum and thalamus. The demonstrated brain anatomy patterns remained stable and were detected after 2 years with Olympic Games in between. We also found differences in the fusiform gyrus in two top long jumpers. We interpret our findings in reward-related areas as correlates of top athletes' persistency to reach top-level skill performance over years.

  8. Do Recipients of an Association-Sponsored Quality Award Program Experience Better Quality Outcomes Compared With Other Nursing Facilities Across the United States?

    PubMed

    Castle, Nicholas; Olson, Doug; Shah, Urvi; Hansen, Kevin

    2016-09-01

    This study explores the relationship between recipients of an association-sponsored Quality Award Program and select measures of quality in U.S. nursing facilities, examined both cross-sectionally and over time. Data used came from Quality Award Program recipients over 9 years (2003-2011) and a set of quality indicators from the Online Survey Certification and Reporting (OSCAR) database. These data were analyzed using a variety of multivariate regression techniques. Cross-sectionally, the award recipients demonstrated higher performance on most of the quality indicators, compared with both the broader field of nursing facilities and also a more stringent comparison group of facilities. Comparing quality from the 4 years before the award was received to the 4 years after the award, the majority of quality indicators demonstrated improvement in those facilities receiving an award. These results indicate that, in general, the nursing facilities that participate in and receive the Silver or Gold American Health Care Association (AHCA) and National Center for Assisted Living (NCAL) National Quality Award perform at a higher level of quality for residents and sustain that heightened performance over a period of time.

  9. Investigating Neuroanatomical Features in Top Athletes at the Single Subject Level

    PubMed Central

    Taubert, Marco; Wenzel, Uwe; Draganski, Bogdan; Kiebel, Stefan J.; Ragert, Patrick; Krug, Jürgen; Villringer, Arno

    2015-01-01

    In sport events like Olympic Games or World Championships competitive athletes keep pushing the boundaries of human performance. Compared to team sports, high achievements in many athletic disciplines depend solely on the individual’s performance. Contrasting previous research looking for expertise-related differences in brain anatomy at the group level, we aim to demonstrate changes in individual top athlete’s brain, which would be averaged out in a group analysis. We compared structural magnetic resonance images (MRI) of three professional track-and-field athletes to age-, gender- and education-matched control subjects. To determine brain features specific to these top athletes, we tested for significant deviations in structural grey matter density between each of the three top athletes and a carefully matched control sample. While total brain volumes were comparable between athletes and controls, we show regional grey matter differences in striatum and thalamus. The demonstrated brain anatomy patterns remained stable and were detected after 2 years with Olympic Games in between. We also found differences in the fusiform gyrus in two top long jumpers. We interpret our findings in reward-related areas as correlates of top athletes’ persistency to reach top-level skill performance over years. PMID:26079870

  10. Synthetic control of manganese birnessite: Impact of crystallite size on Li, Na, and Mg based electrochemistry

    DOE PAGES

    Yin, Jiefu; Takeuchi, Esther S.; Takeuchi, Kenneth J.; ...

    2016-08-12

    We demonstrated the synthesis and characterization of Mg-birnessite (Mg xMnO 2) with different crystallite sizes, prepared though low temperature precipitation and ion exchange. The influence of crystallite size on electrochemical performance of Mg-birnessite was studied for the first time, where material with smaller crystallite size was demonstrated to have enhanced capacity and rate capability in Li ion, Na ion, and Mg ion based electrolytes. Cation diffusion using GITT type testing demonstrated the ion diffusion coefficient of Mg 2+ was ~10× lower compared with Li + and Na +. This work illustrates that tuning of inorganic materials properties can lead tomore » significant enhancement of electrochemical performance in lithium, sodium as well as magnesium based batteries for materials such as Mg-birnessite and provides a deliberate approach to improve electrochemical performance.« less

  11. Analytical and clinical performance characteristics of the Abbott RealTime MTB RIF/INH Resistance, an assay for the detection of rifampicin and isoniazid resistant Mycobacterium tuberculosis in pulmonary specimens.

    PubMed

    Kostera, Joshua; Leckie, Gregor; Tang, Ning; Lampinen, John; Szostak, Magdalena; Abravaya, Klara; Wang, Hong

    2016-12-01

    Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  12. Investigating Simulated Driving Errors in Amnestic Single- and Multiple-Domain Mild Cognitive Impairment.

    PubMed

    Hird, Megan A; Vesely, Kristin A; Fischer, Corinne E; Graham, Simon J; Naglie, Gary; Schweizer, Tom A

    2017-01-01

    The areas of driving impairment characteristic of mild cognitive impairment (MCI) remain unclear. This study compared the simulated driving performance of 24 individuals with MCI, including amnestic single-domain (sd-MCI, n = 11) and amnestic multiple-domain MCI (md-MCI, n = 13), and 20 age-matched controls. Individuals with MCI committed over twice as many driving errors (20.0 versus 9.9), demonstrated difficulty with lane maintenance, and committed more errors during left turns with traffic compared to healthy controls. Specifically, individuals with md-MCI demonstrated greater driving difficulty compared to healthy controls, relative to those with sd-MCI. Differentiating between different subtypes of MCI may be important when evaluating driving safety.

  13. Measuring Adult Literacy in Health Care: Performance of the Newest Vital Sign

    ERIC Educational Resources Information Center

    Osborn, Chandra Y.; Weiss, Barry D.; Davis, Terry C.; Skripkauskas, Silvia; Rodrigue, Christopher; Bass, Pat F., III; Wolf, Michael S.

    2007-01-01

    Objective: To compare performance of the newest vital sign (NVS) with existing literacy measures. Methods: We administered the NVS and REALM to 129 patients, and NVS and S-TOFHLA to 119 patients all in public clinics. Results: The NVS demonstrated high sensitivity for detecting limited literacy and moderate specificity (area under the receiver…

  14. Counting and Comparing School Performance: An Analysis of Media Coverage of PISA in Australia, 2000-2014

    ERIC Educational Resources Information Center

    Baroutsis, Aspa; Lingard, Bob

    2017-01-01

    This paper empirically documents media portrayals of Australia's performance on the Program for the International Student Assessment (PISA), 2000-2014. We analyse newspaper articles from two national and eight metropolitan newspapers. This analysis demonstrates increased media coverage of PISA over the period in question. Our research data were…

  15. Scanner baseliner monitoring and control in high volume manufacturing

    NASA Astrophysics Data System (ADS)

    Samudrala, Pavan; Chung, Woong Jae; Aung, Nyan; Subramany, Lokesh; Gao, Haiyong; Gomez, Juan-Manuel

    2016-03-01

    We analyze performance of different customized models on baseliner overlay data and demonstrate the reduction in overlay residuals by ~10%. Smart Sampling sets were assessed and compared with the full wafer measurements. We found that performance of the grid can still be maintained by going to one-third of total sampling points, while reducing metrology time by 60%. We also demonstrate the feasibility of achieving time to time matching using scanner fleet manager and thus identify the tool drifts even when the tool monitoring controls are within spec limits. We also explore the scanner feedback constant variation with illumination sources.

  16. Socioeconomic disparities in the utilization of mechanical thrombectomy for acute ischemic stroke in US hospitals.

    PubMed

    Brinjikji, W; Rabinstein, A A; McDonald, J S; Cloft, H J

    2014-03-01

    Previous studies have demonstrated that socioeconomic disparities in the treatment of cerebrovascular diseases exist. We studied a large administrative data base to study disparities in the utilization of mechanical thrombectomy for acute ischemic stroke. With the utilization of the Perspective data base, we studied disparities in mechanical thrombectomy utilization between patient race and insurance status in 1) all patients presenting with acute ischemic stroke and 2) patients presenting with acute ischemic stroke at centers that performed mechanical thrombectomy. We examined utilization rates of mechanical thrombectomy by race/ethnicity (white, black, and Hispanic) and insurance status (Medicare, Medicaid, self-pay, and private). Multivariate logistic regression analysis adjusting for potential confounding variables was performed to study the association between race/insurance status and mechanical thrombectomy utilization. The overall mechanical thrombectomy utilization rate was 0.15% (371/249,336); utilization rate at centers that performed mechanical thrombectomy was 1.0% (371/35,376). In the sample of all patients with acute ischemic stroke, multivariate logistic regression analysis demonstrated that uninsured patients had significantly lower odds of mechanical thrombectomy utilization compared with privately insured patients (OR = 0.52, 95% CI = 0.25-0.95, P = .03), as did Medicare patients (OR = 0.53, 95% CI = 0.41-0.70, P < .0001). Blacks had significantly lower odds of mechanical thrombectomy utilization compared with whites (OR = 0.35, 95% CI = 0.23-0.51, P < .0001). When considering only patients treated at centers performing mechanical thrombectomy, multivariate logistic regression analysis demonstrated that insurance was not associated with significant disparities in mechanical thrombectomy utilization; however, black patients had significantly lower odds of mechanical thrombectomy utilization compared with whites (OR = 0.41, 95% CI = 0.27-0.60, P < .0001). Significant socioeconomic disparities exist in the utilization of mechanical thrombectomy in the United States.

  17. Comparing new BSN RN self skills assessment to actual skills demonstration.

    PubMed

    Adair, Jean; Hughes, Lin; Davis, Sue; Wolcott-Breci, Mary

    2014-01-01

    The purpose of the study was to compare the self-skills assessment with the skill competence during an actual skills demonstration of newly hired bachelor of science in nursing (BSN) registered nurse graduates. This retrospective study included 32 randomly selected BSN registered nurse graduates from January 2010 to December 31, 2010. The participants were already hired into a midwest health system. Because this was a retrospective study, no demographic data were collected, and no consent from participants was needed. This study included a clinical skills check list where the participants rated themselves on specific skills utilizing a Likert scale ranging from 1 (no knowledge) to 4 (able to perform independently). The same clinical check list was utilized by an expert registered nurse when the skill was demonstrated. This study compared the difference between the subject's self-rating of skills and the clinical demonstration of the skills. We used t tests in the analysis to demonstrate the differences between the participant's self-rating of skills and the expert evaluation of the clinical demonstration of the skills. The data were inserted into the Statistical Package for the Social Sciences 19 software program to assist in the analysis process. The study demonstrated 17 significant differences in the skills ratings between the participant and competency demonstration of new BSN graduates. These significant results (2 tailed) ranged from .000 to .048.The 17 out of 46 specific skills where differences were noted included the following: staple removal, nasal pharyngeal suctioning, urinary catheter specimen collection, site care dressing change, urinary catheter irrigation, Juzo application and measurement, 5-lead telemetry, oral airway insertion, hemovac/Jackson Pratt, oral pharyngeal suctioning, urinary catheter insertion, dry suction chest drainage, bed to cart/slider board, urinary catheter removal, antiembolism stockings, measurement and application, removal of iv and sit-and-stand alarm. Overall, the participants rated their skill levels lower in 15 out of 17 significant skills when compared with their competency assessment (t test: -3.284, df = 31, P = .003). In two skill ratings (urinary catheter specimen collection and oral pharyngeal suction), the participants rated themselves higher than the competency demonstration. Two skills that had a mean participant and expert score between 1 (no knowledge) and 2 (able to perform with 1-to-1 coaching) were oral airway insertion and dry suction chest drainage. Some possible reasons why the participants rated themselves lower could be the use of different or unfamiliar terms or uncertainty of the procedure at a different health institution. Some newly graduated BSN nurses may have not performed the skills on a regular basis or only in simulation. © 2014.

  18. Computed Tomography Window Blending: Feasibility in Thoracic Trauma.

    PubMed

    Mandell, Jacob C; Wortman, Jeremy R; Rocha, Tatiana C; Folio, Les R; Andriole, Katherine P; Khurana, Bharti

    2018-02-07

    This study aims to demonstrate the feasibility of processing computed tomography (CT) images with a custom window blending algorithm that combines soft-tissue, bone, and lung window settings into a single image; to compare the time for interpretation of chest CT for thoracic trauma with window blending and conventional window settings; and to assess diagnostic performance of both techniques. Adobe Photoshop was scripted to process axial DICOM images from retrospective contrast-enhanced chest CTs performed for trauma with a window-blending algorithm. Two emergency radiologists independently interpreted the axial images from 103 chest CTs with both blended and conventional windows. Interpretation time and diagnostic performance were compared with Wilcoxon signed-rank test and McNemar test, respectively. Agreement with Nexus CT Chest injury severity was assessed with the weighted kappa statistic. A total of 13,295 images were processed without error. Interpretation was faster with window blending, resulting in a 20.3% time saving (P < .001), with no difference in diagnostic performance, within the power of the study to detect a difference in sensitivity of 5% as determined by post hoc power analysis. The sensitivity of the window-blended cases was 82.7%, compared to 81.6% for conventional windows. The specificity of the window-blended cases was 93.1%, compared to 90.5% for conventional windows. All injuries of major clinical significance (per Nexus CT Chest criteria) were correctly identified in all reading sessions, and all negative cases were correctly classified. All readers demonstrated near-perfect agreement with injury severity classification with both window settings. In this pilot study utilizing retrospective data, window blending allows faster preliminary interpretation of axial chest CT performed for trauma, with no significant difference in diagnostic performance compared to conventional window settings. Future studies would be required to assess the utility of window blending in clinical practice. Copyright © 2018 The Association of University Radiologists. All rights reserved.

  19. A comparative study of interface reconstruction methods for multi-material ALE simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kucharik, Milan; Garimalla, Rao; Schofield, Samuel

    2009-01-01

    In this paper we compare the performance of different methods for reconstructing interfaces in multi-material compressible flow simulations. The methods compared are a material-order-dependent Volume-of-Fluid (VOF) method, a material-order-independent VOF method based on power diagram partitioning of cells and the Moment-of-Fluid method (MOF). We demonstrate that the MOF method provides the most accurate tracking of interfaces, followed by the VOF method with the right material ordering. The material-order-independent VOF method performs some-what worse than the above two while the solutions with VOF using the wrong material order are considerably worse.

  20. Simulating the Use of Alternative Fuels in a Turbofan Engine

    NASA Technical Reports Server (NTRS)

    Litt, Jonathan S.; Chin, Jeffrey Chevoor; Liu, Yuan

    2013-01-01

    The interest in alternative fuels for aviation has created a need to evaluate their effect on engine performance. The use of dynamic turbofan engine simulations enables the comparative modeling of the performance of these fuels on a realistic test bed in terms of dynamic response and control compared to traditional fuels. The analysis of overall engine performance and response characteristics can lead to a determination of the practicality of using specific alternative fuels in commercial aircraft. This paper describes a procedure to model the use of alternative fuels in a large commercial turbofan engine, and quantifies their effects on engine and vehicle performance. In addition, the modeling effort notionally demonstrates that engine performance may be maintained by modifying engine control system software parameters to account for the alternative fuel.

  1. A psychometric study of the Test of Everyday Attention for Children in the Chinese setting.

    PubMed

    Chan, Raymond C K; Wang, Li; Ye, Jiawen; Leung, Winnie W Y; Mok, Monica Y K

    2008-07-01

    To explore the psychometric properties of the Test of Everyday Attention for Children (TEA-Ch) in the context of a Chinese setting. Confirmatory factor analysis was conducted to examine the construct validity of the Chinese version of the TEA-Ch among a group of 232 children without attention deficit hyperactivity disorder (ADHD). Test-retest reliability was tested on a random sub-sample of 20 children at a 4-week interval. Clinical discrimination was also examined by comparing children with and without ADHD (22 in each group) on the performances of the TEA-Ch. The current Chinese sample demonstrated a three-factor solution for attentional performance among children without ADHD, namely selective attention, executive control/switch, and sustained attention (chi(2)(24)=34.56; RMSEA=.044; p=.075). Moreover, the whole test demonstrated acceptable test-retest reliability at a 4-week interval among a small sub-sample. Children with ADHD performed significantly more poorly than healthy controls in most of the subtests of the TEA-Ch. The results of the present study demonstrate that the test items remain useful in China, a culture very different from that in which the test originated. Finally, the TEA-Ch also presents several advantages when compared to other conventional objective measures of attention.

  2. Time domain topology optimization of 3D nanophotonic devices

    NASA Astrophysics Data System (ADS)

    Elesin, Y.; Lazarov, B. S.; Jensen, J. S.; Sigmund, O.

    2014-02-01

    We present an efficient parallel topology optimization framework for design of large scale 3D nanophotonic devices. The code shows excellent scalability and is demonstrated for optimization of broadband frequency splitter, waveguide intersection, photonic crystal-based waveguide and nanowire-based waveguide. The obtained results are compared to simplified 2D studies and we demonstrate that 3D topology optimization may lead to significant performance improvements.

  3. Patch antenna terahertz photodetectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palaferri, D.; Todorov, Y., E-mail: yanko.todorov@univ-paris-diderot.fr; Chen, Y. N.

    2015-04-20

    We report on the implementation of 5 THz quantum well photodetector exploiting a patch antenna cavity array. The benefit of our plasmonic architecture on the detector performance is assessed by comparing it with detectors made using the same quantum well absorbing region, but processed into a standard 45° polished facet mesa. Our results demonstrate a clear improvement in responsivity, polarization insensitivity, and background limited performance. Peak detectivities in excess of 5 × 10{sup 12} cmHz{sup 1/2}/W have been obtained, a value comparable with that of the best cryogenic cooled bolometers.

  4. Computational Fluid Dynamic Investigation of Loss Mechanisms in a Pulse-Tube Refrigerator

    NASA Astrophysics Data System (ADS)

    Martin, K.; Esguerra, J.; Dodson, C.; Razani, A.

    2015-12-01

    In predicting Pulse-Tube Cryocooler (PTC) performance, One-Dimensional (1-D) PTR design and analysis tools such as Gedeon Associates SAGE® typically include models for performance degradation due to thermodynamically irreversible processes. SAGE®, in particular, accounts for convective loss, turbulent conductive loss and numerical diffusion “loss” via correlation functions based on analysis and empirical testing. In this study, we compare CFD and SAGE® estimates of PTR refrigeration performance for four distinct pulse-tube lengths. Performance predictions from PTR CFD models are compared to SAGE® predictions for all four cases. Then, to further demonstrate the benefits of higher-fidelity and multidimensional CFD simulation, the PTR loss mechanisms are characterized in terms of their spatial and temporal locations.

  5. Multi-threaded Sparse Matrix Sparse Matrix Multiplication for Many-Core and GPU Architectures.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deveci, Mehmet; Trott, Christian Robert; Rajamanickam, Sivasankaran

    Sparse Matrix-Matrix multiplication is a key kernel that has applications in several domains such as scientific computing and graph analysis. Several algorithms have been studied in the past for this foundational kernel. In this paper, we develop parallel algorithms for sparse matrix- matrix multiplication with a focus on performance portability across different high performance computing architectures. The performance of these algorithms depend on the data structures used in them. We compare different types of accumulators in these algorithms and demonstrate the performance difference between these data structures. Furthermore, we develop a meta-algorithm, kkSpGEMM, to choose the right algorithm and datamore » structure based on the characteristics of the problem. We show performance comparisons on three architectures and demonstrate the need for the community to develop two phase sparse matrix-matrix multiplication implementations for efficient reuse of the data structures involved.« less

  6. Multi-threaded Sparse Matrix-Matrix Multiplication for Many-Core and GPU Architectures.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deveci, Mehmet; Rajamanickam, Sivasankaran; Trott, Christian Robert

    Sparse Matrix-Matrix multiplication is a key kernel that has applications in several domains such as scienti c computing and graph analysis. Several algorithms have been studied in the past for this foundational kernel. In this paper, we develop parallel algorithms for sparse matrix-matrix multiplication with a focus on performance portability across different high performance computing architectures. The performance of these algorithms depend on the data structures used in them. We compare different types of accumulators in these algorithms and demonstrate the performance difference between these data structures. Furthermore, we develop a meta-algorithm, kkSpGEMM, to choose the right algorithm and datamore » structure based on the characteristics of the problem. We show performance comparisons on three architectures and demonstrate the need for the community to develop two phase sparse matrix-matrix multiplication implementations for efficient reuse of the data structures involved.« less

  7. Comparative Proteomic and Nutritional Composition Analysis of Independent Transgenic Pigeon Pea Seeds Harboring cry1AcF and cry2Aa Genes and Their Nontransgenic Counterparts.

    PubMed

    Mishra, Pragya; Singh, Shweta; Rathinam, Maniraj; Nandiganti, Muralimohan; Ram Kumar, Nikhil; Thangaraj, Arulprakash; Thimmegowda, Vinutha; Krishnan, Veda; Mishra, Vagish; Jain, Neha; Rai, Vandna; Pattanayak, Debasis; Sreevathsa, Rohini

    2017-02-22

    Safety assessment of genetically modified plants is an important aspect prior to deregulation. Demonstration of substantial equivalence of the transgenics compared to their nontransgenic counterparts can be performed using different techniques at various molecular levels. The present study is a first-ever comprehensive evaluation of pigeon pea transgenics harboring two independent cry genes, cry2Aa and cry1AcF. The absence of unintended effects in the transgenic seed components was demonstrated by proteome and nutritional composition profiling. Analysis revealed that no significant differences were found in the various nutritional compositional analyses performed. Additionally, 2-DGE-based proteome analysis of the transgenic and nontransgenic seed protein revealed that there were no major changes in the protein profile, although a minor fold change in the expression of a few proteins was observed. Furthermore, the study also demonstrated that neither the integration of T-DNA nor the expression of the cry genes resulted in the production of unintended effects in the form of new toxins or allergens.

  8. Tracking Plasticity: Effects of Long-Term Rehearsal in Expert Dancers Encoding Music to Movement

    PubMed Central

    Bar, Rachel J.; DeSouza, Joseph F. X.

    2016-01-01

    Our knowledge of neural plasticity suggests that neural networks show adaptation to environmental and intrinsic change. In particular, studies investigating the neuroplastic changes associated with learning and practicing motor tasks have shown that practicing such tasks results in an increase in neural activation in several specific brain regions. However, studies comparing experts and non-experts suggest that experts employ less neuronal activation than non-experts when performing a familiar motor task. Here, we aimed to determine the long-term changes in neural networks associated with learning a new dance in professional ballet dancers over 34 weeks. Subjects visualized dance movements to music while undergoing fMRI scanning at four time points over 34-weeks. Results demonstrated that initial learning and performance at seven weeks led to increases in activation in cortical regions during visualization compared to the first week. However, at 34 weeks, the cortical networks showed reduced activation compared to week seven. Specifically, motor learning and performance over the 34 weeks showed the typical inverted-U-shaped function of learning. Further, our result demonstrate that learning of a motor sequence of dance movements to music in the real world can be visualized by expert dancers using fMRI and capture highly significant modeled fits of the brain network variance of BOLD signals from early learning to expert level performance. PMID:26824475

  9. Progress in the utilization of an oxide-dispersion-strengthened alloy for small engine turbine blades

    NASA Technical Reports Server (NTRS)

    Beatty, T. G.; Millan, P. P.

    1984-01-01

    The conventional means of improving gas turbine engine performance typically involves increasing the turbine inlet temperature; however, at these higher operational temperatures the high pressure turbine blades require air-cooling to maintain durability. Air-cooling imposes design, material, and economic constraints not only on the turbine blades but also on engine performance. The use of uncooled turbine blades at increased operating temperatures can offer significantly improved performance in small gas turbine engines. A program to demonstrate uncooled MA6000 high pressure turbine blades in a GTEC TFE731 turbofan engine is being conducted. The project goals include demonstration of the advantages of using uncooled MA6000 turbine blades as compared with cast directionally solidified MAR-M 247 blades.

  10. Context-Dependent Learning in People With Parkinson's Disease.

    PubMed

    Lee, Ya-Yun; Winstein, Carolee J; Gordon, James; Petzinger, Giselle M; Zelinski, Elizabeth M; Fisher, Beth E

    2016-01-01

    Context-dependent learning is a phenomenon in which people demonstrate superior performance in the context in which they originally learned a skill but perform less well in a novel context. This study investigated context-dependent learning in people with Parkinson's disease (PD) and age-matched nondisabled adults. All participants practiced 3 finger sequences, each embedded within a unique context (colors and locations on a computer screen). One day after practice, the participants were tested either under the sequence-context associations remained the same as during practice, or the sequence-context associations were changed (SWITCH). Compared with nondisabled adults, people with PD demonstrated significantly greater decrement in performance (especially movement time) under the SWITCH condition, suggesting that individuals with PD are more context dependent than nondisabled adults.

  11. E-ELT M5 field stabilisation unit scale 1 demonstrator design and performances evaluation

    NASA Astrophysics Data System (ADS)

    Casalta, J. M.; Barriga, J.; Ariño, J.; Mercader, J.; San Andrés, M.; Serra, J.; Kjelberg, I.; Hubin, N.; Jochum, L.; Vernet, E.; Dimmler, M.; Müller, M.

    2010-07-01

    The M5 Field stabilization Unit (M5FU) for European Extremely Large Telescope (E-ELT) is a fast correcting optical system that shall provide tip-tilt corrections for the telescope dynamic pointing errors and the effect of atmospheric tiptilt and wind disturbances. A M5FU scale 1 demonstrator (M5FU1D) is being built to assess the feasibility of the key elements (actuators, sensors, mirror, mirror interfaces) and the real-time control algorithm. The strict constraints (e.g. tip-tilt control frequency range 100Hz, 3m ellipse mirror size, mirror first Eigen frequency 300Hz, maximum tip/tilt range +/- 30 arcsec, maximum tiptilt error < 40 marcsec) have been a big challenge for developing the M5FU Conceptual Design and its scale 1 demonstrator. The paper summarises the proposed design for the final unit and demonstrator and the measured performances compared to the applicable specifications.

  12. A Whole-Tumor Histogram Analysis of Apparent Diffusion Coefficient Maps for Differentiating Thymic Carcinoma from Lymphoma.

    PubMed

    Zhang, Wei; Zhou, Yue; Xu, Xiao-Quan; Kong, Ling-Yan; Xu, Hai; Yu, Tong-Fu; Shi, Hai-Bin; Feng, Qing

    2018-01-01

    To assess the performance of a whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in differentiating thymic carcinoma from lymphoma, and compare it with that of a commonly used hot-spot region-of-interest (ROI)-based ADC measurement. Diffusion weighted imaging data of 15 patients with thymic carcinoma and 13 patients with lymphoma were retrospectively collected and processed with a mono-exponential model. ADC measurements were performed by using a histogram-based and hot-spot-ROI-based approach. In the histogram-based approach, the following parameters were generated: mean ADC (ADC mean ), median ADC (ADC median ), 10th and 90th percentile of ADC (ADC 10 and ADC 90 ), kurtosis, and skewness. The difference in ADCs between thymic carcinoma and lymphoma was compared using a t test. Receiver operating characteristic analyses were conducted to determine and compare the differentiating performance of ADCs. Lymphoma demonstrated significantly lower ADC mean , ADC median , ADC 10 , ADC 90 , and hot-spot-ROI-based mean ADC than those found in thymic carcinoma (all p values < 0.05). There were no differences found in the kurtosis ( p = 0.412) and skewness ( p = 0.273). The ADC 10 demonstrated optimal differentiating performance (cut-off value, 0.403 × 10 -3 mm 2 /s; area under the receiver operating characteristic curve [AUC], 0.977; sensitivity, 92.3%; specificity, 93.3%), followed by the ADC mean , ADC median , ADC 90 , and hot-spot-ROI-based mean ADC. The AUC of ADC 10 was significantly higher than that of the hot spot ROI based ADC (0.977 vs. 0.797, p = 0.036). Compared with the commonly used hot spot ROI based ADC measurement, a histogram analysis of ADC maps can improve the differentiating performance between thymic carcinoma and lymphoma.

  13. Delivering colonoscopy screening for low-income populations in Suffolk County: strategies, outcomes, and benchmarks.

    PubMed

    Lane, Dorothy S; Messina, Catherine R; Cavanagh, Mary F; Anderson, Joseph C

    2013-08-01

    Current and pending legislation provides colorectal cancer screening reimbursement for previously uninsured populations. Colonoscopy is currently the screening method most frequently recommended by physicians for insured patients. The experience of the SCOPE (Suffolk County Preventive Endoscopy) demonstration project (Project SCOPE) at Stony Brook University Medical Center provides a model for delivering colonoscopy screening to low-income populations to meet anticipated increasing demands. Project SCOPE, based in the Department of Preventive Medicine, featured internal collaboration with the academic medical center's large gastroenterology practice and external collaboration with the Suffolk County Department of Health Services' network of community health centers. Colonoscopies were performed by faculty gastroenterologists or supervised fellows. Measures of colonoscopy performance were compared with quality indicators and differences between faculty and supervised fellows were identified. During a 40-month screening period, 800 initial colonoscopies were performed. Approximately 21% of women screened were found to have adenomatous polyps compared with 36% of men. Five cancers were detected. The majority of the population screened (70%) were members of minority populations. African American individuals had a higher percentage of proximally located adenomas (78%) compared with white individuals (65%) and Hispanics (49%), based on the location of the most advanced lesion. Hispanic individuals had a 36% lower risk of adenomas compared with white individuals. Performance measures including the percentage of procedures with adequate bowel preparation, cecum reached, scope withdrawal time, and adenoma detection rate met quality benchmarks when performed by either faculty or supervised fellows. Project SCOPE's operational strategies demonstrated a feasible method for an academic medical center to provide high-quality screening colonoscopy for low-income populations. © 2013 American Cancer Society.

  14. Improved Cognition While Cycling in Parkinson’s Disease Patients and Healthy Adults

    PubMed Central

    Hazamy, Audrey A.; Altmann, Lori J. P.; Stegemöller, Elizabeth; Bowers, Dawn; Lee, Hyo Keun; Wilson, Jonathan; Okun, Michael S.; Hass, Chris J.

    2017-01-01

    Persons with Parkinson’s disease (PD) are typically more susceptible than healthy adults to impaired performance when two tasks (dual task interference) are performed simultaneously. This limitation has by many experts been attributed to limitations in cognitive resources. Nearly all studies of dual task performance in PD employ walking or balance-based motor tasks, which are commonly impaired in PD. These tasks can be performed using a combination of one or two executive function tasks. The current study examined whether persons with PD would demonstrate greater dual task effects on cognition compared to healthy older adults (HOAs) during a concurrent cycling task. Participants with and without PD completed a battery of 12 cognitive tasks assessing visual and verbal processing in the following cognitive domains: speed of processing, controlled processing, working memory and executive function. Persons with PD exhibited impairments compared to healthy participants in select tasks (i.e., 0-Back, 2-Back and operation span). Further, both groups unexpectedly exhibited dual task facilitation of response times in visual tasks across cognitive domains, and improved verbal recall during an executive function task. Only one measure, 2-back, showed a speed-accuracy trade-off in the dual task. These results demonstrate that, when paired with a motor task in which they are not impaired, people with PD exhibit similar dual task effects on cognitive tasks as HOAs, even when these dual task effects are facilitative. More generally, these findings demonstrate that pairing cognitive tasks with cycling may actually improve cognitive performance which may have therapeutic relevance to cognitive decline associated with aging and PD pathology. PMID:28088064

  15. Extrapyramidal signs in normal pressure hydrocephalus: an objective assessment

    PubMed Central

    Mandir, Allen S; Hilfiker, Jennifer; Thomas, George; Minahan, Robert E; Crawford, Thomas O; Williams, Michael A; Rigamonti, Daniele

    2007-01-01

    Background Beyond the classic Normal Pressure Hydrocephalus (NPH) triad of gait disturbance, incontinence, and dementia are characteristic signs of motor dysfunction in NPH patients. We used highly sensitive and objective methods to characterize upper limb extrapyramidal signs in a series of NPH subjects compared with controls. Concentrated evaluation of these profound, yet underappreciated movement disorders of NPH before and after techniques of therapeutic intervention may lead to improved diagnosis, insight into pathophysiology, and targeted treatment. Methods Twenty-two (22) consecutive NPH patients and 17 controls performed an upper limb motor task battery where highly sensitive and objective measures of akinesia/bradykinesia, tone, and tremor were conducted. NPH subjects performed this test battery before and more than 36 h after continuous CSF drainage via a spinal catheter over 72 h and, in those subjects undergoing permanent ventriculo-peritoneal shunt placement, at least 12 weeks later. Control subjects performed the task battery at the same dates as the NPH subjects. Statistical analyses were applied to group populations of NPH and control subjects and repeated measures for within subject performance. Results Twenty (20) NPH subjects remained in the study following CSF drainage as did 14 controls. NPH subjects demonstrated akinesia/bradykinesia (prolonged reaction and movement times) and increased resting tone compared with controls. Furthermore, the NPH group demonstrated increased difficulty with self-initiated tasks compared with stimulus-initiated tasks. Following CSF drainage, some NPH subjects demonstrated reduced movement times with greater improvement in self- versus stimulus-initiated tasks. Group reaction time was unchanged. Resting tremor present in one NPH subject resolved following shunt placement. Tone measures were consistent for all subjects throughout the study. Conclusion Clinical motor signs of NPH subjects extend beyond gait deficits and include extrapyramidal manifestations of bradykinesia, akinesia, rigidity, and propensity to perform more poorly when external cues to move are absent. Objective improvement of some but not all of these features was seen following temporary or permanent CSF diversion. PMID:17697324

  16. Does training frequency and supervision affect compliance, performance and muscular health? A cluster randomized controlled trial.

    PubMed

    Dalager, Tina; Bredahl, Thomas G V; Pedersen, Mogens T; Boyle, Eleanor; Andersen, Lars L; Sjøgaard, Gisela

    2015-10-01

    The aim was to determine the effect of one weekly hour of specific strength training within working hours, performed with the same total training volume but with different training frequencies and durations, or with different levels of supervision, on compliance, muscle health and performance, behavior and work performance. In total, 573 office workers were cluster-randomized to: 1 WS: one 60-min supervised session/week, 3 WS: three 20-min supervised sessions/week, 9 WS: nine 7-min supervised sessions/week, 3 MS: three 20-min sessions/week with minimal supervision, or REF: a reference group without training. Outcomes were diary-based compliance, total training volume, muscle performance and questionnaire-based health, behavior and work performance. Comparisons were made among the WS training groups and between 3 WS and 3 MS. If no difference, training groups were collapsed (TG) and compared with REF. Results demonstrated similar degrees of compliance, mean(range) of 39(33-44)%, and total training volume, 13.266(11.977-15.096)kg. Musculoskeletal pain in neck and shoulders were reduced with approx. 50% in TG, which was significant compared with REF. Only the training groups improved significantly their muscle strength 8(4-13)% and endurance 27(12-37)%, both being significant compared with REF. No change in workability, productivity or self-rated health was demonstrated. Secondary analysis showed exercise self-efficacy to be a significant predictor of compliance. Regardless of training schedule and supervision, similar degrees of compliance were shown together with reduced musculoskeletal pain and improved muscle performance. These findings provide evidence that a great degree of flexibility is legitimate for companies in planning future implementation of physical exercise programs at the workplace. ClinicalTrials.gov, number NCT01027390. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Characterizing Impulsivity in Mania

    PubMed Central

    Strakowski, Stephen M.; Fleck, David E.; DelBello, Melissa P.; Adler, Caleb M.; Shear, Paula K.; McElroy, Susan L.; Keck, Paul E.; Moss, Quinton; Cerullo, Michael A.; Kotwal, Renu; Arndt, Stephan

    2008-01-01

    Objective To determine whether specific aspects of impulsivity (response disinhibition, inability to delay gratification, inattention) differ between healthy and bipolar manic subjects, and whether these aspects of impulsivity were associated with each other and severity of affective symptoms. Methods Performance of 70 bipolar I manic or mixed patients was compared to that of 34 healthy subjects on three tasks specifically designed to study response inhibition, ability to delay gratification, and attention; namely a stop signal task, a delayed reward task, and a continuous performance task respectively. Correlations among tasks and with symptom ratings were also performed. Results Bipolar subjects demonstrated significant deficits on all three tasks as compared to healthy subjects. Performance on the three tasks was largely independent. Task performance was not significantly associated with the severity of affective symptom ratings. However, measures of response inhibition and attention were sensitive to medication effects. Differences in the delayed reward task were independent of medication effects or symptom ratings. During the delayed reward task, although bipolar patients made their choices more slowly than healthy subjects, they were significantly more likely to choose a smaller, but more quickly obtained reward. Moreover performance on this task was not associated with performance on the other impulsivity measures. Manic patients showed more impulsive responding than mixed patients. Conclusions Bipolar I manic patients demonstrate deficits on tests of various aspects of impulsivity as compared to healthy subjects. Some of these differences between groups may be mediated by medication effects. Findings suggested that inability to delay gratification (i.e., delayed reward task) was not simply a result of the speed of decision making or inattention, but rather that it reflected differences between bipolar and healthy subjects in the valuation of reward relative to delay. PMID:19133965

  18. Evaluation of safety and mobility of two-lane roundabouts : final report.

    DOT National Transportation Integrated Search

    2017-07-01

    When looking at measures of fatal and severe-injury crashes, roundabouts have demonstrated improved safety performance compared to traditional signalized intersections. Despite this, when it comes to less severe crashes, multilane roundabouts fail to...

  19. Cold Helium Pressurization for Liquid Oxygen/Liquid Methane Propulsion Systems: Fully-Integrated Hot-Fire Test Results

    NASA Technical Reports Server (NTRS)

    Morehead, R. L.; Atwell, M. J.; Melcher, J. C.; Hurlbert, E. A.

    2016-01-01

    Hot-fire test demonstrations were successfully conducted using a cold helium pressurization system fully integrated into a liquid oxygen (LOX) / liquid methane (LCH4) propulsion system (Figure 1). Cold helium pressurant storage at near liquid nitrogen (LN2) temperatures (-275 F and colder) and used as a heated tank pressurant provides a substantial density advantage compared to ambient temperature storage. The increased storage density reduces helium pressurant tank size and mass, creating payload increases of 35% for small lunar-lander sized applications. This degree of mass reduction also enables pressure-fed propulsion systems for human-rated Mars ascent vehicle designs. Hot-fire test results from the highly-instrumented test bed will be used to demonstrate system performance and validate integrated models of the helium and propulsion systems. A pressurization performance metric will also be developed as a means to compare different active pressurization schemes.

  20. A Pilot Study Assessing Performance and Visual Attention of Teenagers with ASD in a Novel Adaptive Driving Simulator.

    PubMed

    Wade, Joshua; Weitlauf, Amy; Broderick, Neill; Swanson, Amy; Zhang, Lian; Bian, Dayi; Sarkar, Medha; Warren, Zachary; Sarkar, Nilanjan

    2017-11-01

    Individuals with Autism Spectrum Disorder (ASD), compared to typically-developed peers, may demonstrate behaviors that are counter to safe driving. The current work examines the use of a novel simulator in two separate studies. Study 1 demonstrates statistically significant performance differences between individuals with (N = 7) and without ASD (N = 7) with regards to the number of turning-related driving errors (p < 0.01). Study 2 shows that both the performance-based feedback group (N = 9) and combined performance- and gaze-sensitive feedback group (N = 8) achieved statistically significant reductions in driving errors following training (p < 0.05). These studies are the first to present results of fine-grained measures of visual attention of drivers and an adaptive driving intervention for individuals with ASD.

  1. Do Children with Visual Impairments Demonstrate Superior Short-term Memory, Memory Strategies, and Metamemory?

    ERIC Educational Resources Information Center

    Wyver, Shirley R.; Markham, Roslyn

    1998-01-01

    This study compared the memory processes underpinning the performance of 19 children with visual impairments and 19 sighted children on the Digit Span subtest of the Wechsler Intelligence Scales. No support was found for claims of the superior performance of children with visual impairments on the subtest nor of a greater awareness of memory…

  2. Reducing dietary protein in pond production of hybrid striped bass (Morone chrysops x M. saxatilis): Effects on fish performance and water quality dynamics

    USDA-ARS?s Scientific Manuscript database

    In previous work, we demonstrated that diets containing 40% digestible protein (DP) (45% crude protein) and 18 %lipid supplemented with Met and Lys resulted in superior performance and nutrient retentions in hybrid striped bass compared to less energy-dense diets when rearing hybrid striped bass at ...

  3. Body position-dependent shift in odor percept present only for perithreshold odors.

    PubMed

    Lundström, Johan N; Boyle, Julie A; Jones-Gotman, Marilyn

    2008-01-01

    We recently demonstrated that a supine position causes a decrease in olfactory sensitivity compared with an upright position. We pursued that initial finding in 3 separate experiments in which we explored the extent of, and mechanism underlying, this phenomenon. In Experiment 1, we replicated the decrease in olfactory sensitivity when in a supine compared with an upright position. In Experiment 2, we measured body position-dependent shifts in physiological variables and sniff measures while smelling suprathreshold odorants and performing a perithreshold odor intensity discrimination task. Olfactory performances were reduced while supine. However, no relationships between the shift in olfactory performances and either the physiological variables or sniff measures were found. In Experiment 3, we determined that there were no position-dependent shifts in ability to discriminate or identify suprathreshold odors or rate them for pleasantness, intensity, or familiarity. However, a drop in scores was observed, and performance was slowed, on a cognitive skill while supine. These results demonstrate a body position-dependent shift in olfactory sensitivity only for perithreshold odors that appears to be mediated by cognitive rather than physiological factors. Implications for olfactory imaging studies are discussed.

  4. On Quantile Regression in Reproducing Kernel Hilbert Spaces with Data Sparsity Constraint

    PubMed Central

    Zhang, Chong; Liu, Yufeng; Wu, Yichao

    2015-01-01

    For spline regressions, it is well known that the choice of knots is crucial for the performance of the estimator. As a general learning framework covering the smoothing splines, learning in a Reproducing Kernel Hilbert Space (RKHS) has a similar issue. However, the selection of training data points for kernel functions in the RKHS representation has not been carefully studied in the literature. In this paper we study quantile regression as an example of learning in a RKHS. In this case, the regular squared norm penalty does not perform training data selection. We propose a data sparsity constraint that imposes thresholding on the kernel function coefficients to achieve a sparse kernel function representation. We demonstrate that the proposed data sparsity method can have competitive prediction performance for certain situations, and have comparable performance in other cases compared to that of the traditional squared norm penalty. Therefore, the data sparsity method can serve as a competitive alternative to the squared norm penalty method. Some theoretical properties of our proposed method using the data sparsity constraint are obtained. Both simulated and real data sets are used to demonstrate the usefulness of our data sparsity constraint. PMID:27134575

  5. Characterization of controlled bone defects using 2D and 3D ultrasound imaging techniques.

    PubMed

    Parmar, Biren J; Longsine, Whitney; Sabonghy, Eric P; Han, Arum; Tasciotti, Ennio; Weiner, Bradley K; Ferrari, Mauro; Righetti, Raffaella

    2010-08-21

    Ultrasound is emerging as an attractive alternative modality to standard x-ray and CT methods for bone assessment applications. As of today, however, there is a lack of systematic studies that investigate the performance of diagnostic ultrasound techniques in bone imaging applications. This study aims at understanding the performance limitations of new ultrasound techniques for imaging bones in controlled experiments in vitro. Experiments are performed on samples of mammalian and non-mammalian bones with controlled defects with size ranging from 400 microm to 5 mm. Ultrasound findings are statistically compared with those obtained from the same samples using standard x-ray imaging modalities and optical microscopy. The results of this study demonstrate that it is feasible to use diagnostic ultrasound imaging techniques to assess sub-millimeter bone defects in real time and with high accuracy and precision. These results also demonstrate that ultrasound imaging techniques perform comparably better than x-ray imaging and optical imaging methods, in the assessment of a wide range of controlled defects both in mammalian and non-mammalian bones. In the future, ultrasound imaging techniques might provide a cost-effective, real-time, safe and portable diagnostic tool for bone imaging applications.

  6. Case Study for the ARRA-funded Ground Source Heat Pump (GSHP) Demonstration at Wilders Grove Solid Waste Service Center in Raleigh, NC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Xiaobing; Malhotra, Mini; Xiong, Zeyu

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a distributed GSHP system for providing all the space conditioning, outdoor air ventilation, and 100% domestic hot water tomore » the Wilders Grove Solid Waste Service Center of City of Raleigh, North Carolina. This case study is based on the analysis of measured performance data, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning and outdoor air ventilation as the demonstrated GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GSHP system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation and improving the operational efficiency of the demonstrated GSHP system.« less

  7. Thermal imager for dismounted infantry

    NASA Astrophysics Data System (ADS)

    Bigwood, Christopher R.; Eccles, Lee; Jones, Arwyn O.; Jones, Berwyn; Meakin, David L.; Rickard, Steve; Robinson, Rob

    2004-12-01

    Thermal Imager for Dismounted Infantry (TIDI), is a UK MOD / Thales Optics Ltd. joint funded technology demonstrator programme and is part of the overall programme managed by QinetiQ. The aim of this programme is to evaluate and demonstrate a cost effective route to equipping the infantry soldier with a small, lightweight, rugged, short range, weapon mounted thermal imaging sight; intended for mass deployment. TIDI is an unusual programme in that the requirement was not rigidly defined in terms of a detailed specification. Instead, the requirement was expressed in terms of the question 'What weapon sight performance can be achieved for a volume production cost of 5000 Euro?' This requirement was subject to the constraints that the sight mass should be less than 500 g and the volume should be less than 500 ml. To address the requirements of this programme, Thales Optics Ltd. have performed a detailed trade-off analysis considering alternative uncooled LWIR sensor formats and technologies. The effect of using alternative sensors on the sight cost, mass, volume, power and performance has been compared. A design study has been performed concentrating on simplification of the optics, mechanics and electronics to minimise the overall sight complexity. Based on this analysis, a demonstrator sight has been designed that is cost effective and suitable for volume manufacture, whilst still offering useful performance to the user. Six technical demonstrator units based on this design have been manufactured and evaluated. This paper will give an overview of the work completed to date on the TIDI program, including a description of the demonstrator hardware and its performance.

  8. Medium-Duty Plug-in Electric Delivery Truck Fleet Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prohaska, Robert; Ragatz, Adam; Simpson, Mike

    2016-06-29

    In this paper, the authors present an overview of medium-duty electric vehicle (EV) operating behavior based on in-use data collected from Smith Newton electric delivery vehicles and compare their performance and operation to conventional diesel trucks operating in the same fleet. The vehicles' drive cycles and operation are analyzed and compared to demonstrate the importance of matching specific EV technologies to the appropriate operational duty cycle. The results of this analysis show that the Smith Newton EVs demonstrated a 68% reduction in energy consumption over the data reporting period compared to the conventional diesel vehicles, as well as a 46.4%more » reduction in carbon dioxide equivalent emissions based on the local energy generation source.« less

  9. Medium-duty plug-in electric delivery truck fleet evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prohaska, Robert; Ragatz, Adam; Simpson, Mike

    2016-06-01

    In this paper, the authors present an overview of medium-duty electric vehicle (EV) operating behavior based on in-use data collected from Smith Newton electric delivery vehicles and compare their performance and operation to conventional diesel trucks operating in the same fleet. The vehicles' drive cycles and operation are analyzed and compared to demonstrate the importance of matching specific EV technologies to the appropriate operational duty cycle. The results of this analysis show that the Smith Newton EVs demonstrated a 68% reduction in energy consumption over the data reporting period compared to the conventional diesel vehicles, as well as a 46.4%more » reduction in carbon dioxide equivalent emissions based on the local energy generation source.« less

  10. Medium-Duty Plug-In Electric Delivery Truck Fleet Evaluation: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prohaska, Robert; Ragatz, Adam; Simpson, Mike

    2016-04-13

    In this paper, the authors present an overview of medium-duty electric vehicle (EV) operating behavior based on in-use data collected from Smith Newton electric delivery vehicles and compare their performance and operation to conventional diesel trucks operating in the same fleet. The vehicles' drive cycles and operation are analyzed and compared to demonstrate the importance of matching specific EV technologies to the appropriate operational duty cycle. The results of this analysis show that the Smith Newton EVs demonstrated a 68% reduction in energy consumption over the data reporting period compared to the conventional diesel vehicles, as well as a 46.4%more » reduction in carbon dioxide equivalent emissions based on the local energy generation source.« less

  11. Transactive System: Part II: Analysis of Two Pilot Transactive Systems using Foundational Theory and Metrics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lian, Jianming; Sun, Y.; Kalsi, Karanjit

    This document is the second of a two-part report. Part 1 reviewed several demonstrations of transactive control and compared them in terms of their payoff functions, control decisions, information privacy, and mathematical solution concepts. It was suggested in Part 1 that these four listed components should be adopted for meaningful comparison and design of future transactive systems. Part 2 proposes qualitative and quantitative metrics that will be needed to compare alternative transactive systems. It then uses the analysis and design principles from Part 1 while conducting more in-depth analysis of two transactive demonstrations: the American Electric Power (AEP) gridSMART Demonstration,more » which used a double –auction market mechanism, and a consensus method like that used in the Pacific Northwest Smart Grid Demonstration. Ultimately, metrics must be devised and used to meaningfully compare alternative transactive systems. One significant contribution of this report is an observation that the decision function used for thermostat control in the AEP gridSMART Demonstration has superior performance if its decision function is recast to more accurately reflect the power that will be used under for thermostatic control under alternative market outcomes.« less

  12. Epidemiology of Injuries Identified at the NFL Scouting Combine and Their Impact on Performance in the National Football League: Evaluation of 2203 Athletes From 2009 to 2015.

    PubMed

    Beaulieu-Jones, Brendin R; Rossy, William H; Sanchez, George; Whalen, James M; Lavery, Kyle P; McHale, Kevin J; Vopat, Bryan G; Van Allen, Joseph J; Akamefula, Ramesses A; Provencher, Matthew T

    2017-07-01

    At the annual National Football League (NFL) Scouting Combine, the medical staff of each NFL franchise performs a comprehensive medical evaluation of all athletes potentially entering the NFL. Currently, little is known regarding the overall epidemiology of injuries identified at the combine and their impact on NFL performance. To determine the epidemiology of injuries identified at the combine and their impact on initial NFL performance. Cohort study; Level of evidence, 3. All previous musculoskeletal injuries identified at the NFL Combine from 2009 to 2015 were retrospectively reviewed. Medical records and imaging reports were examined. Game statistics for the first 2 seasons of NFL play were obtained for all players from 2009 to 2013. Analysis of injury prevalence and overall impact on the draft status and position-specific performance metrics of each injury was performed and compared with a position-matched control group with no history of injury or surgery. A total of 2203 athletes over 7 years were evaluated, including 1490 (67.6%) drafted athletes and 1040 (47.2%) who ultimately played at least 2 years in the NFL. The most common sites of injury were the ankle (1160, 52.7%), shoulder (1143, 51.9%), knee (1128, 51.2%), spine (785, 35.6%), and hand (739, 33.5%). Odds ratios (ORs) demonstrated that quarterbacks were most at risk of shoulder injury (OR, 2.78; P = .001), while running backs most commonly sustained ankle (OR, 1.39; P = .040) and shoulder injuries (OR, 1.55; P = .020) when compared with all other players. Ultimately, defensive players demonstrated a greater negative impact due to injury than offensive players, with multiple performance metrics significantly affected for each defensive position analyzed, whereas skilled offensive players (eg, quarterbacks, running backs) demonstrated only 1 metric significantly affected at each position. The most common sites of injury identified at the combine were (1) ankle, (2) shoulder, (3) knee, (4) spine, and (5) hand. Overall, performance in the NFL tended to worsen with injury history, with a direct correlation found between injury at a certain anatomic location and position of play. Defensive players tended to perform worse compared with offensive players if injury history was present.

  13. Epidemiology of Injuries Identified at the NFL Scouting Combine and Their Impact on Performance in the National Football League: Evaluation of 2203 Athletes From 2009 to 2015

    PubMed Central

    Beaulieu-Jones, Brendin R.; Rossy, William H.; Sanchez, George; Whalen, James M.; Lavery, Kyle P.; McHale, Kevin J.; Vopat, Bryan G.; Van Allen, Joseph J.; Akamefula, Ramesses A.; Provencher, Matthew T.

    2017-01-01

    Background: At the annual National Football League (NFL) Scouting Combine, the medical staff of each NFL franchise performs a comprehensive medical evaluation of all athletes potentially entering the NFL. Currently, little is known regarding the overall epidemiology of injuries identified at the combine and their impact on NFL performance. Purpose: To determine the epidemiology of injuries identified at the combine and their impact on initial NFL performance. Study Design: Cohort study; Level of evidence, 3. Methods: All previous musculoskeletal injuries identified at the NFL Combine from 2009 to 2015 were retrospectively reviewed. Medical records and imaging reports were examined. Game statistics for the first 2 seasons of NFL play were obtained for all players from 2009 to 2013. Analysis of injury prevalence and overall impact on the draft status and position-specific performance metrics of each injury was performed and compared with a position-matched control group with no history of injury or surgery. Results: A total of 2203 athletes over 7 years were evaluated, including 1490 (67.6%) drafted athletes and 1040 (47.2%) who ultimately played at least 2 years in the NFL. The most common sites of injury were the ankle (1160, 52.7%), shoulder (1143, 51.9%), knee (1128, 51.2%), spine (785, 35.6%), and hand (739, 33.5%). Odds ratios (ORs) demonstrated that quarterbacks were most at risk of shoulder injury (OR, 2.78; P = .001), while running backs most commonly sustained ankle (OR, 1.39; P = .040) and shoulder injuries (OR, 1.55; P = .020) when compared with all other players. Ultimately, defensive players demonstrated a greater negative impact due to injury than offensive players, with multiple performance metrics significantly affected for each defensive position analyzed, whereas skilled offensive players (eg, quarterbacks, running backs) demonstrated only 1 metric significantly affected at each position. Conclusion: The most common sites of injury identified at the combine were (1) ankle, (2) shoulder, (3) knee, (4) spine, and (5) hand. Overall, performance in the NFL tended to worsen with injury history, with a direct correlation found between injury at a certain anatomic location and position of play. Defensive players tended to perform worse compared with offensive players if injury history was present. PMID:28812033

  14. Intra-Platform Repeatability and Inter-Platform Comparability of MicroRNA Microarray Technology

    PubMed Central

    Sato, Fumiaki; Tsuchiya, Soken; Terasawa, Kazuya; Tsujimoto, Gozoh

    2009-01-01

    Over the last decade, DNA microarray technology has provided a great contribution to the life sciences. The MicroArray Quality Control (MAQC) project demonstrated the way to analyze the expression microarray. Recently, microarray technology has been utilized to analyze a comprehensive microRNA expression profiling. Currently, several platforms of microRNA microarray chips are commercially available. Thus, we compared repeatability and comparability of five different microRNA microarray platforms (Agilent, Ambion, Exiqon, Invitrogen and Toray) using 309 microRNAs probes, and the Taqman microRNA system using 142 microRNA probes. This study demonstrated that microRNA microarray has high intra-platform repeatability and comparability to quantitative RT-PCR of microRNA. Among the five platforms, Agilent and Toray array showed relatively better performances than the others. However, the current lineup of commercially available microRNA microarray systems fails to show good inter-platform concordance, probably because of lack of an adequate normalization method and severe divergence in stringency of detection call criteria between different platforms. This study provided the basic information about the performance and the problems specific to the current microRNA microarray systems. PMID:19436744

  15. Demonstration of no-VOC/no-HAP wood furniture coating system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, E.W.; Guan, R.; McCrillis, R.C.

    1997-12-31

    The United States Environmental Protection Agency has contracted with AeroVironment Environmental Services, Inc. and its subcontractor, Adhesive Coating Co., to develop and demonstrate a no-VOC (volatile organic compound)/no-HAP (hazardous air pollutant) wood furniture coating system. The objectives of this project are to develop a new wood coating system that is sufficiently mature for demonstration and to develop a technology transfer plan to get the product into public use. The performance characteristics of this new coating system are excellent in terms of adhesion, drying times, gloss, hardness, mar resistance, level of solvents, and stain resistance. Workshops will be held to providemore » detailed information to wood furniture manufacturers on what is required to change to the new coating system. Topics such as spray gun selection, spray techniques, coating repair procedures, drying times and procedures, and spray equipment cleaning materials and techniques will be presented. A cost analysis, including costs of materials, capital outlay, and labor will be conducted comparing costs to finish furniture with the new system to systems currently used. Film performance, coating materials cost per unit production, productivity, manufacturing changes, and emission levels will be compared in the workshops, based on data gathered during the in-plant, full scale demonstrations.« less

  16. A geometric performance assessment of the EO-1 advanced land imager

    USGS Publications Warehouse

    Storey, James C.; Choate, M.J.; Meyer, D.J.

    2004-01-01

    The Earth Observing 1 (EO-1) Advanced Land Imager (ALI) demonstrates technology applicable to a successor system to the Landsat Thematic Mapper series. A study of the geometric performance characteristics of the ALI was conducted under the auspices of the EO-1 Science Validation Team. This study evaluated ALI performance with respect to absolute pointing knowledge, focal plane sensor chip assembly alignment, and band-to-band registration for purposes of comparing this new technology to the heritage Landsat systems. On-orbit geometric calibration procedures were developed that allowed the generation of ALI geometrically corrected products that compare favorably with their Landsat 7 counterparts with respect to absolute geodetic accuracy, internal image geometry, and band registration.

  17. Cognitive Performance Is Related to Central Sensitization and Health-related Quality of Life in Patients with Chronic Whiplash-Associated Disorders and Fibromyalgia.

    PubMed

    Coppieters, Iris; Ickmans, Kelly; Cagnie, Barbara; Nijs, Jo; De Pauw, Robby; Noten, Suzie; Meeus, Mira

    2015-01-01

    A growing body of research has demonstrated that impaired central pain modulation or central sensitization (CS) is a crucial mechanism for the development of persistent pain in chronic whiplash-associated disorders (WAD) and fibromyalgia (FM) patients. Furthermore, there is increasing evidence for cognitive dysfunctions among these patients. In addition, chronic WAD and FM patients often report problems with health-related quality of life (QoL). Yet, there is limited research concerning the interrelations between cognitive performance, indices of CS, and health-related QoL in these patients. (1) Examining the presence of cognitive impairment, CS, and limitations on health-related QoL in patients with chronic WAD and FM compared to healthy controls. (2) Examining interrelations between performance-based cognitive functioning, CS, and self-reported health-related QoL in these 3 study groups. A case-control study was conducted. The present study took place at the University Hospital Brussels, the University of Brussels, and the University of Antwerp. Fifty-nine patients (16 chronic WAD patients, 21 FM patients, and 22 pain-free volunteers) filled out the Short Form 36 item Health Survey (SF-36), a self-reported psychosocial questionnaire, to assess health-related QoL. Next, they were subjected to various pain measurements (pressure hyperalgesia, deep-tissue hyperalgesia, temporal summation [TS], and conditioned pain modulation [CPM]). Finally, participants completed a battery of performance-based cognitive tests (Stroop task, psychomotor vigilance task [PVT], and operation span task [OSPAN]). Significant cognitive impairment, bottom-up sensitization, and decreased health-related QoL were demonstrated in patients with chronic WAD and FM compared to healthy controls (P < 0.017). CPM was comparable between the 3 groups. Cognitive performance was significantly related to central pain modulation (deep-tissue hyperalgesia, TS, CPM) as well as to self-reported health-related QoL (P < 0.05). Decreased cognitive performance was related to deficient central pain modulation in healthy controls. Further, significant correlations between decreased cognitive performance and reduced health-related QoL were revealed among all study groups. Additionally, FM patients showed correlations between cognitive impairment and increased health-related QoL. Remarkably, impaired selective attention and working memory were related to less TS, whereas impaired sustained attention was correlated with dysfunctional CPM in FM patients. Based on the current cross-sectional study no firm conclusions can be drawn on the causality of the relations. In conclusion, this paper has demonstrated significant cognitive deficits, signs of CS, and reduced health-related QoL in chronic WAD and FM patients compared to healthy individuals. Significant relations between cognitive performance and CS as well as health-related QoL were demonstrated. These results provide preliminary evidence for the clinical importance of objectively measured cognitive deficits in patients with chronic WAD and FM. Chronic pain, fibromyalgia, whiplash, central sensitization, conditioned pain modulation, temporal summation, cognition, quality of life.

  18. A controlled comparison of the BacT/ALERT® 3D and VIRTUO™ microbial detection systems.

    PubMed

    Totty, H; Ullery, M; Spontak, J; Viray, J; Adamik, M; Katzin, B; Dunne, W M; Deol, P

    2017-10-01

    The performance of the next-generation BacT/ALERT® VIRTUO™ Microbial Detection System (VIRTUO™, bioMérieux Inc., Hazelwood, MO) was compared to the BacT/ALERT® 3D Microbial Detection System (3D, bioMérieux Inc., Durham, NC) using BacT/ALERT® FA Plus (FA Plus), BacT/ALERT® PF Plus (PF Plus), BacT/ALERT® FN Plus (FN Plus), BacT/ALERT® Standard Aerobic (SA), and BacT/ALERT® Standard Anaerobic (SN) blood culture bottles (bioMérieux Inc., Durham, NC). A seeded limit of detection (LoD) study was performed for each bottle type in both systems. The LoD studies demonstrated that both systems were capable of detecting organisms at nearly identical levels [<10 colony-forming units (CFU) per bottle], with no significant difference. Following LoD determination, a seeded study was performed to compare the time to detection (TTD) between the systems using a panel of clinically relevant microorganisms inoculated at or near the LoD with 0, 4, or 10 mL of healthy human blood. VIRTUO™ exhibited a faster TTD by an average of 3.5 h, as well as demonstrated a significantly improved detection rate of 99.9% compared to 98.8% with 3D (p-value <0.05).

  19. Diagnostic quality of 50 and 100 µm computed radiography compared with screen–film mammography in operative breast specimens

    PubMed Central

    Pagliari, C M; Hoang, T; Reddy, M; Wilkinson, L S; Poloniecki, J D; Given-Wilson, R M

    2012-01-01

    Objective To compare reader ratings of the clinical diagnostic quality of 50 and 100 μm computed radiography (CR) systems with screen–film mammography (SFM) in operative specimens. Methods Mammograms of 57 fresh operative breast specimens were analysed by 10 readers. Exposures were made with identical position and compression with three mammographic systems (Fuji 100CR, 50CR and SFM). Images were anonymised and readers blinded to the CR system used. A five-point comparative scoring system (−2 to +2) was used to assess seven quality criteria and overall diagnostic value. Statistical analysis was subsequently performed of reader ratings (n=16 925). Results For most quality criteria, both CR systems were rated as equivalent to or better than SFM. The CR systems were significantly better at demonstrating skin edge and background tissue (p<1×10−5). Microcalcification was best demonstrated on the CR50 system (p<1×10−5). The overall diagnostic value of both CR systems was rated as being as good as or better than SFM (p<1×10−5). Conclusion In this clinical setting, the overall diagnostic performance of both CR systems was as good as or better than SFM, with the CR50 system performing better than the CR100. PMID:22096218

  20. [Comparative study of the performance of leather and plastic skate boots].

    PubMed

    Roy, B; Grenier, R

    1982-03-01

    The authors have tried to demonstrate the influence of leather skate boots and plastic boots on the performance of Atome hockey players. Speed tests and joint flexibility tests by means of rotentgenograms showed that besides the speed tests where the leather boot appeared to perform a little better than the plastic boot, no significant difference could be found between both types of boots. It seems to be more a matter of individual choice and adaptation.

  1. [Diagnostic performance of biliary ultrasound vs. magnetic resonance cholangiogram in patients with recurrent biliary obstruction.].

    PubMed

    Chávez-Valencia, V; Espinosa-Ortega, H F; Espinoza-Peralta, D; Arce-Salinas, C A

    2009-01-01

    Obstructive jaundice in patients with previous cholecystectomy requires a precise diagnosis. In the diagnostic algorithm, biliary ultrasound (BUS) and magnetic resonance cholangiogram (MRC) are used, although the accuracy of each method is unknown in our setting. No previous comparison of US and MRC in subjects with cholecystectomy has been made. To determine diagnostic accuracy of BUS and MRC in patients with recurrent biliary obstruction. Patients with endoscopic retrograde cholangiopacreatography (ERCP) demonstrating recurrent biliary obstruction by stones were included. All patients underwent BUS and MRC. We determined the diagnostic performance of each image study compared with ERCP. Twenty-seven patients with a mean age of 62.9 +/- 17.3 years-old were included. Sensitivity and specificity of BUS were 0.12 and 0.58, respectively. Figures for MRC were 0.88 and 0.82. Diagnostic agreement between ERCP and MRC was k= 0.66 whereas BUS had a k of only 0.26. MRC had good diagnostic performance for recurrent choledocolithiasis. BUS demonstrated lower accuracy compared with previous reports, so should not be considered in the initial approach of recurrent choledocus obstruction.

  2. Visual word ambiguity.

    PubMed

    van Gemert, Jan C; Veenman, Cor J; Smeulders, Arnold W M; Geusebroek, Jan-Mark

    2010-07-01

    This paper studies automatic image classification by modeling soft assignment in the popular codebook model. The codebook model describes an image as a bag of discrete visual words selected from a vocabulary, where the frequency distributions of visual words in an image allow classification. One inherent component of the codebook model is the assignment of discrete visual words to continuous image features. Despite the clear mismatch of this hard assignment with the nature of continuous features, the approach has been successfully applied for some years. In this paper, we investigate four types of soft assignment of visual words to image features. We demonstrate that explicitly modeling visual word assignment ambiguity improves classification performance compared to the hard assignment of the traditional codebook model. The traditional codebook model is compared against our method for five well-known data sets: 15 natural scenes, Caltech-101, Caltech-256, and Pascal VOC 2007/2008. We demonstrate that large codebook vocabulary sizes completely deteriorate the performance of the traditional model, whereas the proposed model performs consistently. Moreover, we show that our method profits in high-dimensional feature spaces and reaps higher benefits when increasing the number of image categories.

  3. Thinking within the box: The relational processing style elicited by counterfactual mind-sets.

    PubMed

    Kray, Laura J; Galinsky, Adam D; Wong, Elaine M

    2006-07-01

    By comparing reality to what might have been, counterfactuals promote a relational processing style characterized by a tendency to consider relationships and associations among a set of stimuli. As such, counterfactual mind-sets were expected to improve performance on tasks involving the consideration of relationships and associations but to impair performance on tasks requiring novel ideas that are uninfluenced by salient associations. The authors conducted several experiments to test this hypothesis. In Experiments 1a and 1b, the authors determined that counterfactual mind-sets increase mental states and preferences for thinking styles consistent with relational thought. Experiment 2 demonstrated a facilitative effect of counterfactual mind-sets on an analytic task involving logical relationships; Experiments 3 and 4 demonstrated that counterfactual mind-sets structure thought and imagination around salient associations and therefore impaired performance on creative generation tasks. In Experiment 5, the authors demonstrated that the detrimental effect of counterfactual mind-sets is limited to creative tasks involving novel idea generation; in a creative association task involving the consideration of relationships between task stimuli, counterfactual mind-sets improved performance. Copyright 2006 APA, all rights reserved.

  4. Brain systems underlying attentional control and emotional distraction during working memory encoding.

    PubMed

    Ziaei, Maryam; Peira, Nathalie; Persson, Jonas

    2014-02-15

    Goal-directed behavior requires that cognitive operations can be protected from emotional distraction induced by task-irrelevant emotional stimuli. The brain processes involved in attending to relevant information while filtering out irrelevant information are still largely unknown. To investigate the neural and behavioral underpinnings of attending to task-relevant emotional stimuli while ignoring irrelevant stimuli, we used fMRI to assess brain responses during attentional instructed encoding within an emotional working memory (WM) paradigm. We showed that instructed attention to emotion during WM encoding resulted in enhanced performance, by means of increased memory performance and reduced reaction time, compared to passive viewing. A similar performance benefit was also demonstrated for recognition memory performance, although for positive pictures only. Functional MRI data revealed a network of regions involved in directed attention to emotional information for both positive and negative pictures that included medial and lateral prefrontal cortices, fusiform gyrus, insula, the parahippocampal gyrus, and the amygdala. Moreover, we demonstrate that regions in the striatum, and regions associated with the default-mode network were differentially activated for emotional distraction compared to neutral distraction. Activation in a sub-set of these regions was related to individual differences in WM and recognition memory performance, thus likely contributing to performing the task at an optimal level. The present results provide initial insights into the behavioral and neural consequences of instructed attention and emotional distraction during WM encoding. © 2013.

  5. Functional Performance of an Enabling Atmosphere Revitalization Subsystem Architecture for Deep Space Exploration Missions

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.; Abney, Morgan B.; Frederick, Kenneth R.; Greenwood, Zachary W.; Kayatin, Matthew J.; Newton, Robert L.; Parrish, Keith J.; Roman, Monsi C.; Takada, Kevin C.; Miller, Lee A.; hide

    2013-01-01

    A subsystem architecture derived from the International Space Station's (ISS) Atmosphere Revitalization Subsystem (ARS) has been functionally demonstrated. This ISS-derived architecture features re-arranged unit operations for trace contaminant control and carbon dioxide removal functions, a methane purification component as a precursor to enhance resource recovery over ISS capability, operational modifications to a water electrolysis-based oxygen generation assembly, and an alternative major atmospheric constituent monitoring concept. Results from this functional demonstration are summarized and compared to the performance observed during ground-based testing conducted on an ISS-like subsystem architecture. Considerations for further subsystem architecture and process technology development are discussed.

  6. Airway Science curriculum demonstration project : summary of initial evaluation findings.

    DOT National Transportation Integrated Search

    1988-10-01

    The performance, perceptions, and characteristics of Airway Science hires were compared with those of traditional hires. As of May 12, 1987. a total of 197 Airway Science candidates had been selected into FAA occupations. The demographic characterist...

  7. Performance evaluation of integrating detectors for near-infrared fluorescence molecular imaging

    NASA Astrophysics Data System (ADS)

    Zhu, Banghe; Rasmussen, John C.; Sevick-Muraca, Eva M.

    2014-05-01

    Although there has been a plethora of devices advanced for clinical translation, there has been no standards to compare and determine the optical device for fluorescence molecular imaging. In this work, we compare different CCD configurations using a solid phantom developed to mimic pM - fM concentrations of near-infrared fluorescent dyes in tissues. Our results show that intensified CCD systems (ICCDs) offer greater contrast at larger signal-tonoise ratios (SNRs) in comparison to their un-intensified CCD systems operated at clinically reasonable, sub-second acquisition times. Furthermore, we compared our investigational ICCD device to the commercial NOVADAQ SPY system, demonstrating different performance in both SNR and contrast.

  8. The differential effects of intrinsic and identified motivation on well-being and performance: prospective, experimental, and implicit approaches to self-determination theory.

    PubMed

    Burton, Kimberly D; Lydon, John E; D'Alessandro, David U; Koestner, Richard

    2006-10-01

    Self-determination theory research has demonstrated that intrinsic and identified self-regulations are associated with successful adaptation. However, few distinctions are typically made between these regulations and their outcomes. In the present studies, the associations between intrinsic and identified motivations and outcomes of psychological well-being and academic performance are compared in educational settings. In Study 1, intrinsic self-regulation predicted psychological well-being, independent of academic performance. In contrast, identified regulation predicted academic performance. Additionally, the more that students demonstrated an identified academic regulation, the more that their psychological well-being was contingent on performance. In Study 2a, priming intrinsic self-regulation led to greater psychological well-being 10 days later. In Study 2b, an implicit measure of identified regulation predicted academic performance 6 weeks later. Results indicate the need to address important distinctions between intrinsic and identified regulations. 2006 APA, all rights reserved

  9. Comparison of Test Stand and Helicopter Oil Cooler Bearing Condition Indicators

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Branning, Jeremy; Wade, Damiel R.; Bolander, Nathan

    2010-01-01

    The focus of this paper was to compare the performance of HUMS condition indicators (CI) when detecting a bearing fault in a test stand or on a helicopter. This study compared data from two sources: first, CI data collected from accelerometers installed on two UH-60 Black Hawk helicopters when oil cooler bearing faults occurred, along with data from helicopters with no bearing faults; and second, CI data that was collected from ten cooler bearings, healthy and faulted, that were removed from fielded helicopters and installed in a test stand. A method using Receiver Operating Characteristic (ROC) curves to compare CI performance was demonstrated. Results indicated the bearing energy CI responded differently for the helicopter and the test stand. Future research is required if test stand data is to be used validate condition indicator performance on a helicopter.

  10. Life-Cycle Assessment of Cookstove Fuels in India and China ...

    EPA Pesticide Factsheets

    A life cycle assessment (LCA) was conducted to compare the environmental footprint of current and possible fuels used for cooking within China and India. Current fuel mix profiles are compared to scenarios of projected differences in and/or cleaner cooking fuels. Results are reported for a suite of relevant life cycle impact assessment indicators: global climate change, energy demand, fossil depletion, water consumption, particulate matter formation, acidification, eutrophication and photochemical smog formation. Traditional fuels demonstrate notably poor relative performance in particulate matter formation, photochemical oxidant formation, freshwater eutrophication, and black carbon emissions. Most fuels demonstrate trade-offs between impact categories. Stove efficiency is found to be a crucial variable determining environmental performance across all impact categories. The study shows that electricity and many of the processed fuels, while yielding emission reductions in homes at the point of use, transfer many of those emissions upstream into the processing and distribution life cycle stage. To conduct LCA study of the cookstove fuels being used in India and China to determine how fuels and stoves compare based on a holistic assessment considering the LCA environmental tradeoffs

  11. Objective structured assessment of technical skills evaluation of theoretical compared with hands-on training of shoulder dystocia management: a randomized controlled trial.

    PubMed

    Buerkle, Bernd; Pueth, Julia; Hefler, Lukas A; Tempfer-Bentz, Eva-Katrin; Tempfer, Clemens B

    2012-10-01

    To compare the skills of performing a shoulder dystocia management algorithm after hands-on training compared with demonstration. We randomized medical students to a 30-minute hands-on (group 1) and a 30-minute demonstration (group 2) training session teaching a standardized shoulder dystocia management scheme on a pelvic training model. Participants were tested with a 22-item Objective Structured Assessment of Technical Skills scoring system after training and 72 hours thereafter. Objective Structured Assessment of Technical Skills scores were the primary outcome. Performance time, self-assessment, confidence, and global rating scale were the secondary outcomes. Statistics were performed using Mann-Whitney U test, χ test, and multiple linear regression analysis. Two hundred three participants were randomized. Objective Structured Assessment of Technical Skills scores were significantly higher in group 1 (n=103) compared with group 2 (n=100) (17.95±3.14 compared with 15.67±3.18, respectively; P<.001). The secondary outcomes global rating scale (GRS; 10.94±2.71 compared with 8.57±2.61, respectively; P<.001), self-assessment (3.15±0.94 compared with 2.72±1.01; P=.002), and confidence (3.72±0.98 compared with 3.34±0.90, respectively; P=.005), but not performance time (3:19±0:48 minutes compared with 3:31±1:05 minutes; P=.1), were also significantly different, favoring group 1. After 72 hours, Objective Structured Assessment of Technical Skills scores were still significantly higher in group 1 (n=67) compared with group 2 (n=60) (18.17±2.76 compared with 14.98±3.03, respectively; P<.001) as were GRS (10.80±2.62 compared with 8.15±2.59; P<.001) and self assessment (SA; 3.44±0.87 compared with 2.95±0.94; P=.003). In a multiple linear regression analysis, group assignment (group 1 compared with 2; P<.001) and sex (P=.002) independently influenced Objective Structured Assessment of Technical Skills scores. Hands-on training helps to achieve a significant improvement of shoulder dystocia management on a pelvic training model. www.ClinicalTrials.gov, NCT01618565. I.

  12. Energy harvesting influences electrochemical performance of microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Lobo, Fernanda Leite; Wang, Xin; Ren, Zhiyong Jason

    2017-07-01

    Microbial fuel cells (MFCs) can be effective power sources for remote sensing, wastewater treatment and environmental remediation, but their performance needs significant improvement. This study systematically analyzes how active harvesting using electrical circuits increased MFC system outputs as compared to passive resistors not only in the traditional maximal power point (MPP) but also in other desired operating points such as the maximum current point (MCP) and the maximum voltage point (MVP). Results show that active harvesting in MPP increased power output by 81-375% and active harvesting in MCP increased Coulombic efficiency by 207-805% compared with resisters operated at the same points. The cyclic voltammograms revealed redox potential shifts and supported the performance data. The findings demonstrate that active harvesting is a very effective approach to improve MFC performance across different operating points.

  13. Simulation of mass storage systems operating in a large data processing facility

    NASA Technical Reports Server (NTRS)

    Holmes, R.

    1972-01-01

    A mass storage simulation program was written to aid system designers in the design of a data processing facility. It acts as a tool for measuring the overall effect on the facility of on-line mass storage systems, and it provides the means of measuring and comparing the performance of competing mass storage systems. The performance of the simulation program is demonstrated.

  14. Quality of Care for PTSD and Depression in the Military Health System

    DTIC Science & Technology

    evaluate the receipt of recommended assessments and treatments. These measures draw on multiple data sources including administrative encounter data...services are effective in reducing symptoms. When comparing performance between 20122013 and 20132014, most measures demonstrated slight improvement ...in 20132014 for over 38,000 active-component service members with PTSD or depression. The assessment includes performance on 30 quality measures to

  15. Green Propellant Infusion Mission

    NASA Image and Video Library

    2013-07-09

    U.S. Senator Mark Udall (D-CO) speaks at a Green Propellant Infusion Mission press conference at the Reserve Officers Association, Tuesday, July 9, 2013 in Washington. The NASA GPIM program, led by Ball Aerospace in conjunction with Aerojet Rocketdyne, is demonstrating a high-performance "green" fuel in space. The propellant used on this mission offers nearly 50 percent better performance when compared to traditional hydrazine. Photo Credit: (NASA/Carla Cioffi)

  16. Green Propellant Infusion Mission

    NASA Image and Video Library

    2013-07-09

    Roger Myers, Executive Director, Aerojet Rocketdyne speaks at a Green Propellant Infusion Mission press conference at the Reserve Officers Association, Tuesday, July 9, 2013 in Washington. The NASA GPIM program, led by Ball Aerospace in conjunction with Aerojet Rocketdyne, is demonstrating a high-performance "green" fuel in space. The propellant used on this mission offers nearly 50 percent better performance when compared to traditional hydrazine. Photo Credit: (NASA/Carla Cioffi)

  17. Propulsion system-flight control integration-flight evaluation and technology transition

    NASA Technical Reports Server (NTRS)

    Burcham, Frank W., Jr.; Gilyard, Glenn B.; Myers, Lawrence P.

    1990-01-01

    Integration of propulsion and flight control systems and their optimization offering significant performance improvement are assessed. In particular, research programs conducted by NASA on flight control systems and propulsion system-flight control interactions on the YF-12 and F-15 aircraft are addressed; these programs have demonstrated increased thrust, reduced fuel consumption, increased engine life, and improved aircraft performance. Focus is placed on altitude control, speed-Mach control, integrated controller design, as well as flight control systems and digital electronic engine control. A highly integrated digital electronic control program is analyzed and compared with a performance seeking control program. It is shown that the flight evaluation and demonstration of these technologies have been a key part in the transition of the concepts to production and operational use on a timely basis.

  18. Application of tissue mesodissection to molecular cancer diagnostics.

    PubMed

    Krizman, David; Adey, Nils; Parry, Robert

    2015-02-01

    To demonstrate clinical application of a mesodissection platform that was developed to combine advantages of laser-based instrumentation with the speed/ease of manual dissection for automated dissection of tissue off standard glass slides. Genomic analysis for KRAS gene mutation was performed on formalin fixed paraffin embedded (FFPE) cancer patient tissue that was dissected using the mesodissection platform. Selected reaction monitoring proteomic analysis for quantitative Her2 protein expression was performed on FFPE patient tumour tissue dissected by a laser-based instrument and the MilliSect instrument. Genomic analysis demonstrates highly confident detection of KRAS mutation specifically in lung cancer cells and not the surrounding benign, non-tumour tissue. Proteomic analysis demonstrates Her2 quantitative protein expression in breast cancer cells dissected manually, by laser-based instrumentation and by MilliSect instrumentation (mesodissection). Slide-mounted tissue dissection is commonly performed using laser-based instruments or manually scraping tissue by scalpel. Here we demonstrate that the mesodissection platform as performed by the MilliSect instrument for tissue dissection is cost-effective; it functions comparably to laser-based dissection and which can be adopted into a clinical diagnostic workflow. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. High Performance Flat Plate Solar Thermal Collector Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rockenbaugh, Caleb; Dean, Jesse; Lovullo, David

    2016-09-01

    This report was prepared for the General Services Administration by the National Renewable Energy Laboratory. The Honeycomb Solar Thermal Collector (HSTC) is a flat plate solar thermal collector that shows promising high efficiencies over a wide range of climate zones. The technical objectives of this study are to: 1) verify collector performance, 2) compare that performance to other market-available collectors, 3) verify overheat protection, and 4) analyze the economic performance of the HSTC both at the demonstration sites and across a matrix of climate zones and utility markets.

  20. The Minnesota Multiphasic Personality Inventory-2-RF in Treatment-Seeking Veterans with History of Mild Traumatic Brain Injury.

    PubMed

    Jurick, S M; Crocker, L D; Keller, A V; Hoffman, S N; Bomyea, J; Jacobson, M W; Jak, A J

    2018-05-30

    This study examined the Minnesota Multiphasic Personality Inventory-Second Edition-Restructured Form (MMPI-2-RF) to better understand symptom presentation in a sample of treatment-seeking Operation Enduring Freedom/Operation Iraqi Freedom (OEF/OIF) Veterans with self-reported history of mild traumatic brain injury (mTBI). Participants underwent a comprehensive clinical neuropsychological battery including performance and symptom validity measures and self-report measures of depressive, posttraumatic, and post-concussive symptomatology. Those with possible symptom exaggeration (SE+) on the MMPI-2-RF were compared with those without (SE-) with regard to injury, psychiatric, validity, and cognitive variables. Between 50% and 87% of participants demonstrated possible symptom exaggeration on one or more MMPI-2-RF validity scales, and a large majority were elevated on content scales related to cognitive, somatic, and emotional complaints. The SE+ group reported higher depressive, posttraumatic, and post-concussive symptomatology, had higher scores on symptom validity measures, and performed more poorly on neuropsychological measures compared with the SE- group. There were no group differences with regard to injury variables or performance validity measures. Participants were more likely to exhibit possible symptom exaggeration on cognitive/somatic compared with traditional psychopathological validity scales. A sizable portion of treatment-seeking OEF/OIF Veterans demonstrated possible symptom exaggeration on MMPI-2-RF validity scales, which was associated with elevated scores on self-report measures and poorer cognitive performance, but not higher rates of performance validity failure, suggesting symptom and performance validity are distinct concepts. These findings have implications for the interpretation of clinical data in the context of possible symptom exaggeration and treatment in Veterans with persistent post-concussive symptoms.

  1. Effects of caffeine and carbohydrate mouth rinses on repeated sprint performance.

    PubMed

    Beaven, C Martyn; Maulder, Peter; Pooley, Adrian; Kilduff, Liam; Cook, Christian

    2013-06-01

    Our purpose was to examine the effectiveness of carbohydrate and caffeine mouth rinses in enhancing repeated sprint ability. Previously, studies have shown that a carbohydrate mouth rinse (without ingestion) has beneficial effects on endurance performance that are related to changes in brain activity. Caffeine ingestion has also demonstrated positive effects on sprint performance. However, the effects of carbohydrate or caffeine mouth rinses on intermittent sprints have not been examined previously. Twelve males performed 5 × 6-s sprints interspersed with 24 s of active recovery on a cycle ergometer. Twenty-five milliliters of either a noncaloric placebo, a 6% glucose, or a 1.2% caffeine solution was rinsed in the mouth for 5 s prior to each sprint in a double-blinded and balanced cross-over design. Postexercise maximal heart rate and perceived exertion were recorded, along with power measures. A second experiment compared a combined caffeine-carbohydrate rinse with carbohydrate only. Compared with the placebo mouth rinse, carbohydrate substantially increased peak power in sprint 1 (22.1 ± 19.5 W; Cohen's effect size (ES), 0.81), and both caffeine (26.9 ± 26.9 W; ES, 0.71) and carbohydrate (39.1 ± 25.8 W; ES, 1.08) improved mean power in sprint 1. Experiment 2 demonstrated that a combination of caffeine and carbohydrate improved sprint 1 power production compared with carbohydrate alone (36.0 ± 37.3 W; ES, 0.81). We conclude that carbohydrate and (or) caffeine mouth rinses may rapidly enhance power production, which could have benefits for specific short sprint exercise performance. The ability of a mouth-rinse intervention to rapidly improve maximal exercise performance in the absence of fatigue suggests a central mechanism.

  2. High-performance green flexible electronics based on biodegradable cellulose nanofibril paper

    PubMed Central

    Jung, Yei Hwan; Chang, Tzu-Hsuan; Zhang, Huilong; Yao, Chunhua; Zheng, Qifeng; Yang, Vina W.; Mi, Hongyi; Kim, Munho; Cho, Sang June; Park, Dong-Wook; Jiang, Hao; Lee, Juhwan; Qiu, Yijie; Zhou, Weidong; Cai, Zhiyong; Gong, Shaoqin; Ma, Zhenqiang

    2015-01-01

    Today's consumer electronics, such as cell phones, tablets and other portable electronic devices, are typically made of non-renewable, non-biodegradable, and sometimes potentially toxic (for example, gallium arsenide) materials. These consumer electronics are frequently upgraded or discarded, leading to serious environmental contamination. Thus, electronic systems consisting of renewable and biodegradable materials and minimal amount of potentially toxic materials are desirable. Here we report high-performance flexible microwave and digital electronics that consume the smallest amount of potentially toxic materials on biobased, biodegradable and flexible cellulose nanofibril papers. Furthermore, we demonstrate gallium arsenide microwave devices, the consumer wireless workhorse, in a transferrable thin-film form. Successful fabrication of key electrical components on the flexible cellulose nanofibril paper with comparable performance to their rigid counterparts and clear demonstration of fungal biodegradation of the cellulose-nanofibril-based electronics suggest that it is feasible to fabricate high-performance flexible electronics using ecofriendly materials. PMID:26006731

  3. Parametric Study of Pulse-Combustor-Driven Ejectors at High-Pressure

    NASA Technical Reports Server (NTRS)

    Yungster, Shaye; Paxson, Daniel E.; Perkins, Hugh D.

    2015-01-01

    Pulse-combustor configurations developed in recent studies have demonstrated performance levels at high-pressure operating conditions comparable to those observed at atmospheric conditions. However, problems related to the way fuel was being distributed within the pulse combustor were still limiting performance. In the first part of this study, new configurations are investigated computationally aimed at improving the fuel distribution and performance of the pulse-combustor. Subsequent sections investigate the performance of various pulse-combustor driven ejector configurations operating at highpressure conditions, focusing on the effects of fuel equivalence ratio and ejector throat area. The goal is to design pulse-combustor-ejector configurations that maximize pressure gain while achieving a thermal environment acceptable to a turbine, and at the same time maintain acceptable levels of NOx emissions and flow non-uniformities. The computations presented here have demonstrated pressure gains of up to 2.8%.

  4. Parametric Study of Pulse-Combustor-Driven Ejectors at High-Pressure

    NASA Technical Reports Server (NTRS)

    Yungster, Shaye; Paxson, Daniel E.; Perkins, Hugh D.

    2015-01-01

    Pulse-combustor configurations developed in recent studies have demonstrated performance levels at high-pressure operating conditions comparable to those observed at atmospheric conditions. However, problems related to the way fuel was being distributed within the pulse combustor were still limiting performance. In the first part of this study, new configurations are investigated computationally aimed at improving the fuel distribution and performance of the pulse-combustor. Subsequent sections investigate the performance of various pulse-combustor driven ejector configurations operating at high pressure conditions, focusing on the effects of fuel equivalence ratio and ejector throat area. The goal is to design pulse-combustor-ejector configurations that maximize pressure gain while achieving a thermal environment acceptable to a turbine, and at the same time maintain acceptable levels of NO(x) emissions and flow non-uniformities. The computations presented here have demonstrated pressure gains of up to 2.8.

  5. High-performance green flexible electronics based on biodegradable cellulose nanofibril paper.

    PubMed

    Jung, Yei Hwan; Chang, Tzu-Hsuan; Zhang, Huilong; Yao, Chunhua; Zheng, Qifeng; Yang, Vina W; Mi, Hongyi; Kim, Munho; Cho, Sang June; Park, Dong-Wook; Jiang, Hao; Lee, Juhwan; Qiu, Yijie; Zhou, Weidong; Cai, Zhiyong; Gong, Shaoqin; Ma, Zhenqiang

    2015-05-26

    Today's consumer electronics, such as cell phones, tablets and other portable electronic devices, are typically made of non-renewable, non-biodegradable, and sometimes potentially toxic (for example, gallium arsenide) materials. These consumer electronics are frequently upgraded or discarded, leading to serious environmental contamination. Thus, electronic systems consisting of renewable and biodegradable materials and minimal amount of potentially toxic materials are desirable. Here we report high-performance flexible microwave and digital electronics that consume the smallest amount of potentially toxic materials on biobased, biodegradable and flexible cellulose nanofibril papers. Furthermore, we demonstrate gallium arsenide microwave devices, the consumer wireless workhorse, in a transferrable thin-film form. Successful fabrication of key electrical components on the flexible cellulose nanofibril paper with comparable performance to their rigid counterparts and clear demonstration of fungal biodegradation of the cellulose-nanofibril-based electronics suggest that it is feasible to fabricate high-performance flexible electronics using ecofriendly materials.

  6. High-performance green flexible electronics based on biodegradable cellulose nanofibril paper

    NASA Astrophysics Data System (ADS)

    Jung, Yei Hwan; Chang, Tzu-Hsuan; Zhang, Huilong; Yao, Chunhua; Zheng, Qifeng; Yang, Vina W.; Mi, Hongyi; Kim, Munho; Cho, Sang June; Park, Dong-Wook; Jiang, Hao; Lee, Juhwan; Qiu, Yijie; Zhou, Weidong; Cai, Zhiyong; Gong, Shaoqin; Ma, Zhenqiang

    2015-05-01

    Today's consumer electronics, such as cell phones, tablets and other portable electronic devices, are typically made of non-renewable, non-biodegradable, and sometimes potentially toxic (for example, gallium arsenide) materials. These consumer electronics are frequently upgraded or discarded, leading to serious environmental contamination. Thus, electronic systems consisting of renewable and biodegradable materials and minimal amount of potentially toxic materials are desirable. Here we report high-performance flexible microwave and digital electronics that consume the smallest amount of potentially toxic materials on biobased, biodegradable and flexible cellulose nanofibril papers. Furthermore, we demonstrate gallium arsenide microwave devices, the consumer wireless workhorse, in a transferrable thin-film form. Successful fabrication of key electrical components on the flexible cellulose nanofibril paper with comparable performance to their rigid counterparts and clear demonstration of fungal biodegradation of the cellulose-nanofibril-based electronics suggest that it is feasible to fabricate high-performance flexible electronics using ecofriendly materials.

  7. Local Navon letter processing affects skilled behavior: a golf-putting experiment.

    PubMed

    Lewis, Michael B; Dawkins, Gemma

    2015-04-01

    Expert or skilled behaviors (for example, face recognition or sporting performance) are typically performed automatically and with little conscious awareness. Previous studies, in various domains of performance, have shown that activities immediately prior to a task demanding a learned skill can affect performance. In sport, describing the to-be-performed action is detrimental, whereas in face recognition, describing a face or reading local Navon letters is detrimental. Two golf-putting experiments are presented that compare the effects that these three tasks have on experienced and novice golfers. Experiment 1 found a Navon effect on golf performance for experienced players. Experiment 2 found, for experienced players only, that performance was impaired following the three tasks described above, when compared with reading or global Navon tasks. It is suggested that the three tasks affect skilled performance by provoking a shift from automatic behavior to a more analytic style. By demonstrating similarities between effects in face recognition and sporting behavior, it is hoped to better understand concepts in both fields.

  8. Encoding-Imagery Specificity in Alcohol State-Dependent Learning

    ERIC Educational Resources Information Center

    Weingartner, Herbert; And Others

    1976-01-01

    A free-recall procedure demonstrated state-dependent learning using alcohol. Information encoded and stored while intoxicated was more effectively retrieved when later tests of recall were performed while intoxicated, as compared to recall accomplished in the sober state. (Editor/RK)

  9. Solar Electric Propulsion Vehicle Demonstration to Support Future Space Exploration Missions

    NASA Technical Reports Server (NTRS)

    Smith, Bryan K.; Nazario, Margaret L.; Cunningham, Cameron C.

    2012-01-01

    Human and robotic exploration beyond Low Earth Orbit (LEO) will require enabling capabilities that are efficient, affordable, and reliable. Solar Electric Propulsion (SEP) is highly advantageous because of its favorable in-space mass transfer efficiency compared to traditional chemical propulsion systems. The NASA studies have demonstrated that this advantage becomes highly significant as missions progress beyond Earth orbit. Recent studies of human exploration missions and architectures evaluated the capabilities needed to perform a variety of human exploration missions including missions to Near Earth Objects (NEOs). The studies demonstrated that SEP stages have potential to be the most cost effective solution to perform beyond LEO transfers of high mass cargoes for human missions. Recognizing that these missions require power levels more than 10X greater than current electric propulsion systems, NASA embarked upon a progressive pathway to identify critical technologies needed and a plan for an incremental demonstration mission. The NASA studies identified a 30kW class demonstration mission that can serve as a meaningful demonstration of the technologies, operational challenges, and provide the appropriate scaling and modularity required. This paper describes the planning options for a representative demonstration 30kW class SEP mission.

  10. Effects of a 6-month exercise program pilot study on walking economy, peak physiological characteristics, and walking performance in patients with peripheral arterial disease.

    PubMed

    Crowther, Robert G; Leicht, Anthony S; Spinks, Warwick L; Sangla, Kunwarjit; Quigley, Frank; Golledge, Jonathan

    2012-01-01

    The purpose of this study was to examine the effects of a 6-month exercise program on submaximal walking economy in individuals with peripheral arterial disease and intermittent claudication (PAD-IC). Participants (n = 16) were randomly allocated to either a control PAD-IC group (CPAD-IC, n = 6) which received standard medical therapy, or a treatment PAD-IC group (TPAD-IC; n = 10) which took part in a supervised exercise program. During a graded treadmill test, physiological responses, including oxygen consumption, were assessed to calculate walking economy during submaximal and maximal walking performance. Differences between groups at baseline and post-intervention were analyzed via Kruskal-Wallis tests. At baseline, CPAD-IC and TPAD-IC groups demonstrated similar walking performance and physiological responses. Postintervention, TPAD-IC patients demonstrated significantly lower oxygen consumption during the graded exercise test, and greater maximal walking performance compared to CPAD-IC. These preliminary results indicate that 6 months of regular exercise improves both submaximal walking economy and maximal walking performance, without significant changes in maximal walking economy. Enhanced walking economy may contribute to physiological efficiency, which in turn may improve walking performance as demonstrated by PAD-IC patients following regular exercise programs.

  11. Generalizable, Electroless, Template-Assisted Synthesis and Electrocatalytic Mechanistic Understanding of Perovskite LaNiO3 Nanorods as Viable, Supportless Oxygen Evolution Reaction Catalysts in Alkaline Media.

    PubMed

    McBean, Coray L; Liu, Haiqing; Scofield, Megan E; Li, Luyao; Wang, Lei; Bernstein, Ashley; Wong, Stanislaus S

    2017-07-26

    The oxygen evolution reaction (OER) is a key reaction for water electrolysis cells and air-powered battery applications. However, conventional metal oxide catalysts, used for high-performing OER, tend to incorporate comparatively expensive and less abundant precious metals such as Ru and Ir, and, moreover, suffer from poor stability. To attempt to mitigate for all of these issues, we have prepared one-dimensional (1D) OER-active perovskite nanorods using a unique, simple, generalizable, and robust method. Significantly, our work demonstrates the feasibility of a novel electroless, seedless, surfactant-free, wet solution-based protocol for fabricating "high aspect ratio" LaNiO 3 and LaMnO 3 nanostructures. As the main focus of our demonstration of principle, we prepared as-synthesized LaNiO 3 rods and correlated the various temperatures at which these materials were annealed with their resulting OER performance. We observed generally better OER performance for samples prepared with lower annealing temperatures. Specifically, when annealed at 600 °C, in the absence of a conventional conductive carbon support, our as-synthesized LaNiO 3 rods not only evinced (i) a reasonable level of activity toward OER but also displayed (ii) an improved stability, as demonstrated by chronoamperometric measurements, especially when compared with a control sample of commercially available (and more expensive) RuO 2 .

  12. A Randomized Trial Comparing Didactics, Demonstration, and Simulation for Teaching Teamwork to Medical Residents

    PubMed Central

    Keriwala, Raj D.; Clune, Jennifer K.; Rice, Todd W.; Pugh, Meredith E.; Wheeler, Arthur P.; Miller, Alison N.; Banerjee, Arna; Terhune, Kyla; Bastarache, Julie A.

    2015-01-01

    Rationale: Effective teamwork is fundamental to the management of medical emergencies, and yet the best method to teach teamwork skills to trainees remains unknown. Objectives: In a cohort of incoming internal medicine interns, we tested the hypothesis that expert demonstration of teamwork principles and participation in high-fidelity simulation would each result in objectively assessed teamwork behavior superior to traditional didactics. Methods: This was a randomized, controlled, parallel-group trial comparing three teamwork teaching modalities for incoming internal medicine interns. Participants in a single-day orientation at the Vanderbilt University Center for Experiential Learning and Assessment were randomized 1:1:1 to didactic, demonstration-based, or simulation-based instruction and then evaluated in their management of a simulated crisis by five independent, blinded observers using the Teamwork Behavioral Rater score. Clinical performance was assessed using the American Heart Association Advanced Cardiac Life Support algorithm and a novel “Recognize, Respond, Reassess” score. Measurements and Main Results: Participants randomized to didactics (n = 18), demonstration (n = 17), and simulation (n = 17) were similar at baseline. The primary outcome of average overall Teamwork Behavioral Rater score for those who received demonstration-based training was similar to simulation participation (4.40 ± 1.15 vs. 4.10 ± 0.95, P = 0.917) and significantly higher than didactic instruction (4.40 ± 1.15 vs. 3.10 ± 0.51, P = 0.045). Clinical performance scores were similar between the three groups and correlated only weakly with teamwork behavior (coefficient of determination [Rs2] = 0.267, P < 0.001). Conclusions: Among incoming internal medicine interns, teamwork training by expert demonstration resulted in similar teamwork behavior to participation in high-fidelity simulation and was more effective than traditional didactics. Clinical performance was largely independent of teamwork behavior and did not differ between training modalities. PMID:25730661

  13. Level of functional capacities following soccer-specific warm-up methods among elite collegiate soccer players.

    PubMed

    Vazini Taher, Amir; Parnow, Abdolhossein

    2017-05-01

    Different methods of warm-up may have implications in improving various aspects of soccer performance. The present study aimed to investigate acute effects of soccer specific warm-up protocols on functional performance tests. This study using randomized within-subject design, investigated the performance of 22 collegiate elite soccer player following soccer specific warm-ups using dynamic stretching, static stretching, and FIFA 11+ program. Post warm-up examinations consisted: 1) Illinois Agility Test; 2) vertical jump; 3) 30 meter sprint; 4) consecutive turns; 5) flexibility of knee. Vertical jump performance was significantly lower following static stretching, as compared to dynamic stretching (P=0.005). Sprint performance declined significantly following static stretching as compared to FIFA 11+ (P=0.023). Agility time was significantly faster following dynamic stretching as compared to FIFA 11+ (P=0.001) and static stretching (P=0.001). Knee flexibility scores were significantly improved following the static stretching as compared to dynamic stretching (P=016). No significant difference was observed for consecutive turns between three warm-up protocol. The present finding showed that a soccer specific warm-up protocol relied on dynamic stretching is preferable in enhancing performance as compared to protocols relying on static stretches and FIFA 11+ program. Investigators suggest that while different soccer specific warm-up protocols have varied types of effects on performance, acute effects of dynamic stretching on performance in elite soccer players are assured, however application of static stretching in reducing muscle stiffness is demonstrated.

  14. Whole exome sequencing for determination of tumor mutation load in liquid biopsy from advanced cancer patients.

    PubMed

    Koeppel, Florence; Blanchard, Steven; Jovelet, Cécile; Genin, Bérengère; Marcaillou, Charles; Martin, Emmanuel; Rouleau, Etienne; Solary, Eric; Soria, Jean-Charles; André, Fabrice; Lacroix, Ludovic

    2017-01-01

    Tumor mutation load (TML) has been proposed as a biomarker of patient response to immunotherapy in several studies. TML is usually determined by tumor biopsy DNA (tDNA) whole exome sequencing (WES), therefore TML evaluation is limited by informative biopsy availability. Circulating cell free DNA (cfDNA) provided by liquid biopsy is a surrogate specimen to biopsy for molecular profiling. Nevertheless performing WES on DNA from plasma is technically challenging and the ability to determine tumor mutation load from liquid biopsies remains to be demonstrated. In the current study, WES was performed on cfDNA from 32 metastatic patients of various cancer types included into MOSCATO 01 (NCT01566019) and/or MATCHR (NCT02517892) molecular triage trials. Results from targeted gene sequencing (TGS) and WES performed on cfDNA were compared to results from tumor tissue biopsy. In cfDNA samples, WES mutation detection sensitivity was 92% compared to targeted sequencing (TGS). When comparing cfDNA-WES to tDNA-WES, mutation detection sensitivity was 53%, consistent with previously published prospective study comparing cfDNA-TGS to tDNA-TGS. For samples in which presence of tumor DNA was confirmed in cfDNA, tumor mutation load from liquid biopsy was correlated with tumor biopsy. Taken together, this study demonstrated that liquid biopsy may be applied to determine tumor mutation load. Qualification of liquid biopsy for interpretation is a crucial point to use cfDNA for mutational load estimation.

  15. Whole exome sequencing for determination of tumor mutation load in liquid biopsy from advanced cancer patients

    PubMed Central

    Blanchard, Steven; Jovelet, Cécile; Genin, Bérengère; Marcaillou, Charles; Martin, Emmanuel; Rouleau, Etienne; Solary, Eric; Soria, Jean-Charles; André, Fabrice; Lacroix, Ludovic

    2017-01-01

    Tumor mutation load (TML) has been proposed as a biomarker of patient response to immunotherapy in several studies. TML is usually determined by tumor biopsy DNA (tDNA) whole exome sequencing (WES), therefore TML evaluation is limited by informative biopsy availability. Circulating cell free DNA (cfDNA) provided by liquid biopsy is a surrogate specimen to biopsy for molecular profiling. Nevertheless performing WES on DNA from plasma is technically challenging and the ability to determine tumor mutation load from liquid biopsies remains to be demonstrated. In the current study, WES was performed on cfDNA from 32 metastatic patients of various cancer types included into MOSCATO 01 (NCT01566019) and/or MATCHR (NCT02517892) molecular triage trials. Results from targeted gene sequencing (TGS) and WES performed on cfDNA were compared to results from tumor tissue biopsy. In cfDNA samples, WES mutation detection sensitivity was 92% compared to targeted sequencing (TGS). When comparing cfDNA-WES to tDNA-WES, mutation detection sensitivity was 53%, consistent with previously published prospective study comparing cfDNA-TGS to tDNA-TGS. For samples in which presence of tumor DNA was confirmed in cfDNA, tumor mutation load from liquid biopsy was correlated with tumor biopsy. Taken together, this study demonstrated that liquid biopsy may be applied to determine tumor mutation load. Qualification of liquid biopsy for interpretation is a crucial point to use cfDNA for mutational load estimation. PMID:29161279

  16. FIELD DEMONSTRATION AND QUALITY ASSURANCE ...

    EPA Pesticide Factsheets

    The Demonstration of innovative field devices for the measurement of mercury in soil and sediment is being conducted under the EPA's SITE Program in February 2003 at the United States Department of Energy's (DOE) Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee and the Tennessee Department of Environment and Conservation's Department of Energy Oversight facility in Oak Ridge, Tennessee. The primary purpose of the Demonstration is to evaluate innovative field devices for the measurement of mercury in soil and sediment based on their performance and cost as compared to a conventional, off-site laboratory analytical method. The five field measurement devices listed below will be demonstrated: .Metorex's X-M ET 2000 Metal Master Analyzer, X-Ray Fluorescence Analyzer .Milestone Inc.'s Direct Mercury Analyzer (DMA-80), Thermal Decomposition Instrument.NITON's XL-700 Series Multi-Element Analyzer, X-Ray Fluorescence Analyzer .Ohio Lumex's RA-915+ Portable Mercury Analyzer, Atomic Absorption Spectrometer, Thermal Decompostion Attachment RP 91C .MTI, Inc.'s PDV 5000 Hand Held Instrument, Anodic Stripping Voltamm eter<1). This Demonstration Plan describes the procedures that will be used to verify the performance and cost of each field measurement device. The plan incorporates the quality assurance and quality control elements needed to generate data of sufficient quality to document each device's performance and cost. A separate Innovative Technology Verifica

  17. Model for Predicting the Performance of Planetary Suit Hip Bearing Designs

    NASA Technical Reports Server (NTRS)

    Cowley, Matthew S.; Margerum, Sarah; Hharvill, Lauren; Rajulu, Sudhakar

    2012-01-01

    Designing a space suit is very complex and often requires difficult trade-offs between performance, cost, mass, and system complexity. During the development period of the suit numerous design iterations need to occur before the hardware meets human performance requirements. Using computer models early in the design phase of hardware development is advantageous, by allowing virtual prototyping to take place. A virtual design environment allows designers to think creatively, exhaust design possibilities, and study design impacts on suit and human performance. A model of the rigid components of the Mark III Technology Demonstrator Suit (planetary-type space suit) and a human manikin were created and tested in a virtual environment. The performance of the Mark III hip bearing model was first developed and evaluated virtually by comparing the differences in mobility performance between the nominal bearing configurations and modified bearing configurations. Suited human performance was then simulated with the model and compared to actual suited human performance data using the same bearing configurations. The Mark III hip bearing model was able to visually represent complex bearing rotations and the theoretical volumetric ranges of motion in three dimensions. The model was also able to predict suited human hip flexion and abduction maximums to within 10% of the actual suited human subject data, except for one modified bearing condition in hip flexion which was off by 24%. Differences between the model predictions and the human subject performance data were attributed to the lack of joint moment limits in the model, human subject fitting issues, and the limited suit experience of some of the subjects. The results demonstrate that modeling space suit rigid segments is a feasible design tool for evaluating and optimizing suited human performance. Keywords: space suit, design, modeling, performance

  18. Pigtail catheters used for percutaneous fluid drainage: comparison of performance characteristics.

    PubMed

    Macha, Douglas B; Thomas, John; Nelson, Rendon C

    2006-03-01

    To compare the performance characteristics of various single-lumen all-purpose pigtail drainage catheters. The following parameters were compared: flow rates between catheters of the same size, whether changing the fluid viscosity has any effect on catheter comparisons, the effect on flow of leaving an open three-way stopcock in the drainage pathway, the tendency of the catheters to kink, and catheter patency after kinking, as measured according to flow. All-purpose 8.0-, 8.3-, and 8.5-F (collectively referred to as 8-F); 10.0-, 10.2-, and 10.3-F (collectively referred to as 10-F); and 12.0-F pigtail drainage catheters from three manufacturers were evaluated. Data were compared by using two-tailed t tests after normal distributions were confirmed. P < .05 was considered to represent a significant difference. At comparison of the 8-F catheters, the C.R. Bard catheters demonstrated better flow rates than the Cook and Boston Scientific devices. Among the 10-F catheters, there were no significant differences in the flow rates of fluid with viscosity equivalent to that of water between the C.R. Bard and Boston Scientific catheters; however, both these catheter types demonstrated significantly (P < .05) better flow rates than the Cook devices. Among the 12-F catheters, the C.R. Bard catheters demonstrated significantly (P < .05) better flow rates than the other two catheter types. Changing the fluid viscosity caused no changes in comparison results. In all catheter groups, the presence of a stopcock significantly (P < .05) impaired flow. None of the evaluated catheters demonstrated a clear advantage in terms of patency or susceptibility to kinking. At comparison of the in vitro performances of catheters from different manufacturers, the C.R. Bard 8.0-F and Cook 10.2-F catheters had comparable flow rates, and flow rates through the C.R. Bard and Boston Scientific 10.0-F catheters were comparable to flow rates through the Cook and Boston Scientific 12.0-F catheters. Varying viscosity had no effect on comparisons of catheter flow rates; however, a stopcock between the vacuum source and the catheter was noted to impair flow rates in all brands and sizes of evaluated catheters. Copyright RSNA, 2006.

  19. SAN/CXFS test report to LLNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruwart, T M; Eldel, A

    2000-01-01

    The primary objectives of this project were to evaluate the performance of the SGI CXFS File System in a Storage Area Network (SAN) and compare/contrast it to the performance of a locally attached XFS file system on the same computer and storage subsystems. The University of Minnesota participants were asked to verify that the performance of the SAN/CXFS configuration did not fall below 85% of the performance of the XFS local configuration. There were two basic hardware test configurations constructed from the following equipment: Two Onyx 2 computer systems each with two Qlogic-based Fibre Channel/XIO Host Bus Adapter (HBA); Onemore » 8-Port Brocade Silkworm 2400 Fibre Channel Switch; and Four Ciprico RF7000 RAID Disk Arrays populated Seagate Barracuda 50GB disk drives. The Operating System on each of the ONYX 2 computer systems was IRIX 6.5.6. The first hardware configuration consisted of directly connecting the Ciprico arrays to the Qlogic controllers without the Brocade switch. The purpose for this configuration was to establish baseline performance data on the Qlogic controllers / Ciprico disk raw subsystem. This baseline performance data would then be used to demonstrate any performance differences arising from the addition of the Brocade Fibre Channel Switch. Furthermore, the performance of the Qlogic controllers could be compared to that of the older, Adaptec-based XIO dual-channel Fibre Channel adapters previously used on these systems. It should be noted that only raw device tests were performed on this configuration. No file system testing was performed on this configuration. The second hardware configuration introduced the Brocade Fibre Channel Switch. Two FC ports from each of the ONYX2 computer systems were attached to four ports of the switch and the four Ciprico arrays were attached to the remaining four. Raw disk subsystem tests were performed on the SAN configuration in order to demonstrate the performance differences between the direct-connect and the switched configurations. After this testing was completed, the Ciprico arrays were formatted with an XFS file system and performance numbers were gathered to establish a File System Performance Baseline. Finally, the disks were formatted with CXFS and further tests were run to demonstrate the performance of the CXFS file system. A summary of the results of these tests is given.« less

  20. REMOTE, a Wireless Sensor Network Based System to Monitor Rowing Performance

    PubMed Central

    Llosa, Jordi; Vilajosana, Ignasi; Vilajosana, Xavier; Navarro, Nacho; Suriñach, Emma; Marquès, Joan Manuel

    2009-01-01

    In this paper, we take a hard look at the performance of REMOTE, a sensor network based application that provides a detailed picture of a boat movement, individual rower performance, or his/her performance compared with other crew members. The application analyzes data gathered with a WSN strategically deployed over a boat to obtain information on the boat and oar movements. Functionalities of REMOTE are compared to those of RowX [1] outdoor instrument, a commercial wired sensor instrument designed for similar purposes. This study demonstrates that with smart geometrical configuration of the sensors, rotation and translation of the oars and boat can be obtained. Three different tests are performed: laboratory calibration allows us to become familiar with the accelerometer readings and validate the theory, ergometer tests which help us to set the acquisition parameters, and on boat tests shows the application potential of this technologies in sports. PMID:22423204

  1. Proposed evaluation framework for assessing operator performance with multisensor displays

    NASA Technical Reports Server (NTRS)

    Foyle, David C.

    1992-01-01

    Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.

  2. Demonstration of a consensus approach for the calculation of physicochemical properties required for environmental fate assessments

    EPA Science Inventory

    Eight software applications are compared for their performance in estimating the octanol-water partition coefficient (Kow), melting point, vapor pressure and water solubility for a dataset of polychlorinated biphenyls, polybrominated diphenyl ethers, polychlorinated dibenzodioxin...

  3. Observational practice of incentive spirometry in stroke patients.

    PubMed

    Lima, Íllia N D F; Fregonezi, Guilherme A F; Florêncio, Rêncio B; Campos, Tânia F; Ferreira, Gardênia H

    Stroke may lead to several health problems, but positive effects can be promoted by learning to perform physical therapy techniques correctly. To compare two different types of observational practice (video instructions and demonstration by a physical therapist) during the use of incentive spirometry (IS). A total of 20 patients with diagnosis of stroke and 20 healthy individuals (56±9.7 years) were allocated into two groups: one with observational practice with video instructions for the use of IS and the other with observational practice with demonstration by a physical therapist. Ten attempts for the correct use of IS were carried out and the number of errors and the magnitude of response were evaluated. The statistic used to compare the results was the three-way ANOVA test. The stroke subjects showed less precision when compared to the healthy individuals (mean difference 1.80±0.38) 95%CI [1.02-2.52], p<0.0001. When the type of practice was analyzed, the stroke subjects showed more errors with the video instructions (mean difference 1.5±0.5, 95%CI [0.43-2.56] (p=0.08)) and therapist demonstration (mean difference 2.40±0.52, 95%CI [1.29-3.50] (p=0.00)) when compared to the healthy individuals. The stroke subjects had a worse performance in learning the use of volume-oriented incentive spirometry when compared to healthy individuals; however, there was no difference between the types of observational practice, suggesting that both may be used to encourage the use of learning IS in patients with stroke. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. Technology evaluation report: SITE (Superfund Innovative Technology Evaluation) program demonstration test. The American Combustion Pyretron Thermal Destruction System at the US EPA's (Environmental Protection Agency's) combustion research facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waterland, L.; Lee, J.W.

    1989-04-01

    A series of demonstration tests of the American Combustion, Inc., Thermal Destruction System was performed under the SITE program. This oxygen-enhanced combustion system was retrofit to the rotary-kiln incinerator at EPA's Combustion Research Facility. The system's performance was tested firing contaminated soil from the Stringfellow Superfund Site, both alone and mixed with a coal tar waste (KO87). Comparative performance with conventional incinerator operation was also tested. Compliance with the incinerator performance standards of 99.99% principal organic hazardous constituents (POHC) destruction and removal efficiency and particulate emissions of less than 180 mg/dscm at 7% O2 was measured for all tests. Themore » Pyretron system was capable of in-compliance performance at double the mixed waste feedrate and at a 60% increase in batch waste charge mass than possible with conventional incineration. Scrubber blowdown and kiln ash contained no detectable levels of any of the POHCs chosen.« less

  5. Biomechanical and Performance Differences Between Female Soccer Athletes in National Collegiate Athletic Association Divisions I and III

    PubMed Central

    Smith, Rose; Ford, Kevin R; Myer, Gregory D; Holleran, Adam; Treadway, Erin; Hewett, Timothy E

    2007-01-01

    Context: The recent increase in women's varsity soccer participation has been accompanied by a lower extremity injury rate that is 2 to 6 times that of their male counterparts. Objective: To define the differences between lower extremity biomechanics (knee abduction and knee flexion measures) and performance (maximal vertical jump height) between National Collegiate Athletic Association Division I and III female soccer athletes during a drop vertical jump. Design: Mixed 2 × 2 design. Setting: Research laboratory. Patients or Other Participants: Thirty-four female collegiate soccer players (Division I: n = 19; Division III: n = 15) participated in the study. The groups were similar in height and mass. Intervention(s): Each subject performed a maximal vertical jump, followed by 3 drop vertical jumps. Main Outcome Measure(s): Kinematics (knee abduction and flexion angles) and kinetics (knee abduction and flexion moments) were measured with a motion analysis system and 2 force platforms during the drop vertical jumps. Results: Knee abduction angular range of motion and knee abduction external moments were not different between groups (P > .05). However, Division I athletes demonstrated decreased knee flexion range of motion (P = .038) and greater peak external knee flexion moment (P = .009) compared with Division III athletes. Division I athletes demonstrated increased vertical jump height compared with Division III (P = .008). Conclusions: Division I athletes demonstrated different sagittal-plane mechanics than Division III athletes, which may facilitate improved performance. The similarities in anterior cruciate ligament injury risk factors (knee abduction torques and angles) may correlate with the consistent incidence of anterior cruciate ligament injury across divisions. PMID:18174935

  6. Natural and Artificial Intelligence in Neurosurgery: A Systematic Review.

    PubMed

    Senders, Joeky T; Arnaout, Omar; Karhade, Aditya V; Dasenbrock, Hormuzdiyar H; Gormley, William B; Broekman, Marike L; Smith, Timothy R

    2017-09-07

    Machine learning (ML) is a domain of artificial intelligence that allows computer algorithms to learn from experience without being explicitly programmed. To summarize neurosurgical applications of ML where it has been compared to clinical expertise, here referred to as "natural intelligence." A systematic search was performed in the PubMed and Embase databases as of August 2016 to review all studies comparing the performance of various ML approaches with that of clinical experts in neurosurgical literature. Twenty-three studies were identified that used ML algorithms for diagnosis, presurgical planning, or outcome prediction in neurosurgical patients. Compared to clinical experts, ML models demonstrated a median absolute improvement in accuracy and area under the receiver operating curve of 13% (interquartile range 4-21%) and 0.14 (interquartile range 0.07-0.21), respectively. In 29 (58%) of the 50 outcome measures for which a P -value was provided or calculated, ML models outperformed clinical experts ( P < .05). In 18 of 50 (36%), no difference was seen between ML and expert performance ( P > .05), while in 3 of 50 (6%) clinical experts outperformed ML models ( P < .05). All 4 studies that compared clinicians assisted by ML models vs clinicians alone demonstrated a better performance in the first group. We conclude that ML models have the potential to augment the decision-making capacity of clinicians in neurosurgical applications; however, significant hurdles remain associated with creating, validating, and deploying ML models in the clinical setting. Shifting from the preconceptions of a human-vs-machine to a human-and-machine paradigm could be essential to overcome these hurdles. Published by Oxford University Press on behalf of Congress of Neurological Surgeons 2017.

  7. Sparse matrix methods research using the CSM testbed software system

    NASA Technical Reports Server (NTRS)

    Chu, Eleanor; George, J. Alan

    1989-01-01

    Research is described on sparse matrix techniques for the Computational Structural Mechanics (CSM) Testbed. The primary objective was to compare the performance of state-of-the-art techniques for solving sparse systems with those that are currently available in the CSM Testbed. Thus, one of the first tasks was to become familiar with the structure of the testbed, and to install some or all of the SPARSPAK package in the testbed. A suite of subroutines to extract from the data base the relevant structural and numerical information about the matrix equations was written, and all the demonstration problems distributed with the testbed were successfully solved. These codes were documented, and performance studies comparing the SPARSPAK technology to the methods currently in the testbed were completed. In addition, some preliminary studies were done comparing some recently developed out-of-core techniques with the performance of the testbed processor INV.

  8. A synthesis of mathematical and cognitive performances of students with mathematics learning disabilities.

    PubMed

    Shin, Mikyung; Bryant, Diane Pedrotty

    2015-01-01

    The purpose of this study was to synthesize the findings from 23 articles that compared the mathematical and cognitive performances of students with mathematics learning disabilities (LD) to (a) students with LD in mathematics and reading, (b) age- or grade-matched students with no LD, and (c) mathematical-ability-matched younger students with no LD. Overall results revealed that students with mathematics LD exhibited higher word problem-solving abilities and no significant group differences on working memory, long-term memory, and metacognition measures compared to students with LD in mathematics and reading. Findings also revealed students with mathematics LD demonstrated significantly lower performance compared to age- or grade-matched students with no LD on both mathematical and cognitive measures. Comparison between students with mathematics LD and younger students with no LD revealed mixed outcomes on mathematical measures and generally no significant group differences on cognitive measures. © Hammill Institute on Disabilities 2013.

  9. Flexible, 31 channel breast coil for enhanced parallel imaging performance at 3T

    PubMed Central

    Hancu, Ileana; Fiveland, Eric; Park, Keith; Giaquinto, Randy O.; Rohling, Kenneth; Wiesinger, Florian

    2015-01-01

    Purpose To design, build and characterize the performance of a novel 3T, 31 channel breast coil. Methods A flexible breast coil, accommodating all breast sizes while preserving close to unity filling factors in all configurations, was designed and built. Its performance was compared to the performance of the current state-of-the-art, 16 channel breast coil (Sentinelle coil, Hologic, Bedford, MA, USA), in phantoms and in vivo. Results Better axilla coverage and lower inter-coil coupling (12% vs. 26%, as characterized by the average off-diagonal elements of the noise correlation matrix) was exhibited by our 31 channel coil compared to the 16 channel coil. Breast area SNR increases of 68% (phantom) and 28 ± 31% (in vivo) were demonstrated in the 3 volunteers studied when the 31 channel coil was used. For the 31 channel/16 channel arrays, respectively, two dimensional acceleration factors of L/R × S/I = 4.3 × 2.4 resulted in average g-factors of 1.10/1.68 (in vitro) and 1.28/2.75 (in vivo); acceleration factors of L/R × A/P = 3.0 × 2.8 resulted in average g-factors of 1.06/1.54 (in vitro) and 1.05/1.12 (in vivo). Conclusion A high performance breast coil was built; its capabilities were demonstrated in phantom and normal volunteer imaging experiments. PMID:25772214

  10. Significantly improved photovoltaic performance in polymer bulk heterojunction solar cells with graphene oxide /PEDOT:PSS double decked hole transport layer

    PubMed Central

    Rafique, Saqib; Abdullah, Shahino Mah; Shahid, Muhammad Mehmood; Ansari, Mohammad Omaish; Sulaiman, Khaulah

    2017-01-01

    This work demonstrates the high performance graphene oxide (GO)/PEDOT:PSS doubled decked hole transport layer (HTL) in the PCDTBT:PC71BM based bulk heterojunction organic photovoltaic device. The devices were tested on merits of their power conversion efficiency (PCE), reproducibility, stability and further compared with the devices with individual GO or PEDOT:PSS HTLs. Solar cells employing GO/PEDOT:PSS HTL yielded a PCE of 4.28% as compared to either of individual GO or PEDOT:PSS HTLs where they demonstrated PCEs of 2.77 and 3.57%, respectively. In case of single GO HTL, an inhomogeneous coating of ITO caused the poor performance whereas PEDOT:PSS is known to be hygroscopic and acidic which upon direct contact with ITO reduced the device performance. The improvement in the photovoltaic performance is mainly ascribed to the increased charge carriers mobility, short circuit current, open circuit voltage, fill factor, and decreased series resistance. The well matched work function of GO and PEDOT:PSS is likely to facilitate the charge transportation and an overall reduction in the series resistance. Moreover, GO could effectively block the electrons due to its large band-gap of ~3.6 eV, leading to an increased shunt resistance. In addition, we also observed the improvement in the reproducibility and stability. PMID:28084304

  11. Significantly improved photovoltaic performance in polymer bulk heterojunction solar cells with graphene oxide /PEDOT:PSS double decked hole transport layer.

    PubMed

    Rafique, Saqib; Abdullah, Shahino Mah; Shahid, Muhammad Mehmood; Ansari, Mohammad Omaish; Sulaiman, Khaulah

    2017-01-13

    This work demonstrates the high performance graphene oxide (GO)/PEDOT:PSS doubled decked hole transport layer (HTL) in the PCDTBT:PC 71 BM based bulk heterojunction organic photovoltaic device. The devices were tested on merits of their power conversion efficiency (PCE), reproducibility, stability and further compared with the devices with individual GO or PEDOT:PSS HTLs. Solar cells employing GO/PEDOT:PSS HTL yielded a PCE of 4.28% as compared to either of individual GO or PEDOT:PSS HTLs where they demonstrated PCEs of 2.77 and 3.57%, respectively. In case of single GO HTL, an inhomogeneous coating of ITO caused the poor performance whereas PEDOT:PSS is known to be hygroscopic and acidic which upon direct contact with ITO reduced the device performance. The improvement in the photovoltaic performance is mainly ascribed to the increased charge carriers mobility, short circuit current, open circuit voltage, fill factor, and decreased series resistance. The well matched work function of GO and PEDOT:PSS is likely to facilitate the charge transportation and an overall reduction in the series resistance. Moreover, GO could effectively block the electrons due to its large band-gap of ~3.6 eV, leading to an increased shunt resistance. In addition, we also observed the improvement in the reproducibility and stability.

  12. Significantly improved photovoltaic performance in polymer bulk heterojunction solar cells with graphene oxide /PEDOT:PSS double decked hole transport layer

    NASA Astrophysics Data System (ADS)

    Rafique, Saqib; Abdullah, Shahino Mah; Shahid, Muhammad Mehmood; Ansari, Mohammad Omaish; Sulaiman, Khaulah

    2017-01-01

    This work demonstrates the high performance graphene oxide (GO)/PEDOT:PSS doubled decked hole transport layer (HTL) in the PCDTBT:PC71BM based bulk heterojunction organic photovoltaic device. The devices were tested on merits of their power conversion efficiency (PCE), reproducibility, stability and further compared with the devices with individual GO or PEDOT:PSS HTLs. Solar cells employing GO/PEDOT:PSS HTL yielded a PCE of 4.28% as compared to either of individual GO or PEDOT:PSS HTLs where they demonstrated PCEs of 2.77 and 3.57%, respectively. In case of single GO HTL, an inhomogeneous coating of ITO caused the poor performance whereas PEDOT:PSS is known to be hygroscopic and acidic which upon direct contact with ITO reduced the device performance. The improvement in the photovoltaic performance is mainly ascribed to the increased charge carriers mobility, short circuit current, open circuit voltage, fill factor, and decreased series resistance. The well matched work function of GO and PEDOT:PSS is likely to facilitate the charge transportation and an overall reduction in the series resistance. Moreover, GO could effectively block the electrons due to its large band-gap of ~3.6 eV, leading to an increased shunt resistance. In addition, we also observed the improvement in the reproducibility and stability.

  13. Word Recall: Cognitive Performance Within Internet Surveys

    PubMed Central

    Craig, Benjamin M; Jim, Heather S

    2015-01-01

    Background The use of online surveys for data collection has increased exponentially, yet it is often unclear whether interview-based cognitive assessments (such as face-to-face or telephonic word recall tasks) can be adapted for use in application-based research settings. Objective The objective of the current study was to compare and characterize the results of online word recall tasks to those of the Health and Retirement Study (HRS) and determine the feasibility and reliability of incorporating word recall tasks into application-based cognitive assessments. Methods The results of the online immediate and delayed word recall assessment, included within the Women’s Health and Valuation (WHV) study, were compared to the results of the immediate and delayed recall tasks of Waves 5-11 (2000-2012) of the HRS. Results Performance on the WHV immediate and delayed tasks demonstrated strong concordance with performance on the HRS tasks (ρc=.79, 95% CI 0.67-0.91), despite significant differences between study populations (P<.001) and study design. Sociodemographic characteristics and self-reported memory demonstrated similar relationships with performance on both the HRS and WHV tasks. Conclusions The key finding of this study is that the HRS word recall tasks performed similarly when used as an online cognitive assessment in the WHV. Online administration of cognitive tests, which has the potential to significantly reduce participant and administrative burden, should be considered in future research studies and health assessments. PMID:26543924

  14. Disruption of Putrescine Biosynthesis in Shewanella oneidensis Enhances Biofilm Cohesiveness and Performance in Cr(VI) Immobilization

    PubMed Central

    Ding, Yuanzhao; Peng, Ni; Du, Yonghua; Ji, Lianghui

    2014-01-01

    Although biofilm-based bioprocesses have been increasingly used in various applications, the long-term robust and efficient biofilm performance remains one of the main bottlenecks. In this study, we demonstrated that biofilm cohesiveness and performance of Shewanella oneidensis can be enhanced through disrupting putrescine biosynthesis. Through random transposon mutagenesis library screening, one hyperadherent mutant strain, CP2-1-S1, exhibiting an enhanced capability in biofilm formation, was obtained. Comparative analysis of the performance of biofilms formed by S. oneidensis MR-1 wild type (WT) and CP2-1-S1 in removing dichromate (Cr2O72−), i.e., Cr(VI), from the aqueous phase showed that, compared with the WT biofilms, CP2-1-S1 biofilms displayed a substantially lower rate of cell detachment upon exposure to Cr(VI), suggesting a higher cohesiveness of the mutant biofilms. In addition, the amount of Cr(III) immobilized by CP2-1-S1 biofilms was much larger, indicating an enhanced performance in Cr(VI) bioremediation. We further showed that speF, a putrescine biosynthesis gene, was disrupted in CP2-1-S1 and that the biofilm phenotypes could be restored by both genetic and chemical complementations. Our results also demonstrated an important role of putrescine in mediating matrix disassembly in S. oneidensis biofilms. PMID:24362428

  15. Performance of the Directigen EZ Flu A+B rapid influenza diagnostic test to detect pandemic influenza A/H1N1 2009.

    PubMed

    Boyanton, Bobby L; Almradi, Amro; Mehta, Tejal; Robinson-Dunn, Barbara

    2014-04-01

    The Directigen EZ Flu A+B rapid influenza diagnostic test, as compared to real-time reverse transcriptase polymerase chain reaction, demonstrated suboptimal performance to detect pandemic influenza A/H1N1 2009. Age- and viral load-stratified test sensitivity ranged from 33.3 to 84.6% and 0 to 100%, respectively. © 2013.

  16. Speaker Linking and Applications using Non-Parametric Hashing Methods

    DTIC Science & Technology

    2016-09-08

    clustering method based on hashing—canopy- clustering . We apply this method to a large corpus of speaker recordings, demonstrate performance tradeoffs...and compare to other hash- ing methods. Index Terms: speaker recognition, clustering , hashing, locality sensitive hashing. 1. Introduction We assume...speaker in our corpus. Second, given a QBE method, how can we perform speaker clustering —each clustering should be a single speaker, and a cluster should

  17. Placebo-suggestion modulates conflict resolution in the Stroop Task.

    PubMed

    Magalhães De Saldanha da Gama, Pedro A; Slama, Hichem; Caspar, Emilie A; Gevers, Wim; Cleeremans, Axel

    2013-01-01

    Here, we ask whether placebo-suggestion (without any form of hypnotic induction) can modulate the resolution of cognitive conflict. Naïve participants performed a Stroop Task while wearing an EEG cap described as a "brain wave" machine. In Experiment 1, participants were made to believe that the EEG cap would either enhance or decrease their color perception and performance on the Stroop task. In Experiment 2, participants were explicitly asked to imagine that their color perception and performance would be enhanced or decreased (non-hypnotic imaginative suggestion). We observed effects of placebo-suggestion on Stroop interference on accuracy: interference was decreased with positive suggestion and increased with negative suggestion compared to baseline. Intra-individual variability was also increased under negative suggestion compared to baseline. Compliance with the instruction to imagine a modulation of performance, on the other hand, did not influence accuracy and only had a negative impact on response latencies and on intra-individual variability, especially in the congruent condition of the Stroop Task. Taken together, these results demonstrate that expectations induced by a placebo-suggestion can modulate our ability to resolve cognitive conflict, either facilitating or impairing response accuracy depending on the suggestion's contents. Our results also demonstrate a dissociation between placebo-suggestion and non-hypnotic imaginative suggestion.

  18. Placebo-Suggestion Modulates Conflict Resolution in the Stroop Task

    PubMed Central

    Caspar, Emilie A.; Gevers, Wim; Cleeremans, Axel

    2013-01-01

    Here, we ask whether placebo-suggestion (without any form of hypnotic induction) can modulate the resolution of cognitive conflict. Naïve participants performed a Stroop Task while wearing an EEG cap described as a “brain wave” machine. In Experiment 1, participants were made to believe that the EEG cap would either enhance or decrease their color perception and performance on the Stroop task. In Experiment 2, participants were explicitly asked to imagine that their color perception and performance would be enhanced or decreased (non-hypnotic imaginative suggestion). We observed effects of placebo-suggestion on Stroop interference on accuracy: interference was decreased with positive suggestion and increased with negative suggestion compared to baseline. Intra-individual variability was also increased under negative suggestion compared to baseline. Compliance with the instruction to imagine a modulation of performance, on the other hand, did not influence accuracy and only had a negative impact on response latencies and on intra-individual variability, especially in the congruent condition of the Stroop Task. Taken together, these results demonstrate that expectations induced by a placebo-suggestion can modulate our ability to resolve cognitive conflict, either facilitating or impairing response accuracy depending on the suggestion’s contents. Our results also demonstrate a dissociation between placebo-suggestion and non-hypnotic imaginative suggestion. PMID:24130735

  19. Performance Analysis of Ranging Techniques for the KPLO Mission

    NASA Astrophysics Data System (ADS)

    Park, Sungjoon; Moon, Sangman

    2018-03-01

    In this study, the performance of ranging techniques for the Korea Pathfinder Lunar Orbiter (KPLO) space communication system is investigated. KPLO is the first lunar mission of Korea, and pseudo-noise (PN) ranging will be used to support the mission along with sequential ranging. We compared the performance of both ranging techniques using the criteria of accuracy, acquisition probability, and measurement time. First, we investigated the end-to-end accuracy error of a ranging technique incorporating all sources of errors such as from ground stations and the spacecraft communication system. This study demonstrates that increasing the clock frequency of the ranging system is not required when the dominant factor of accuracy error is independent of the thermal noise of the ranging technique being used in the system. Based on the understanding of ranging accuracy, the measurement time of PN and sequential ranging are further investigated and compared, while both techniques satisfied the accuracy and acquisition requirements. We demonstrated that PN ranging performed better than sequential ranging in the signal-to-noise ratio (SNR) regime where KPLO will be operating, and we found that the T2B (weighted-voting balanced Tausworthe, voting v = 2) code is the best choice among the PN codes available for the KPLO mission.

  20. Detection of food intake from swallowing sequences by supervised and unsupervised methods.

    PubMed

    Lopez-Meyer, Paulo; Makeyev, Oleksandr; Schuckers, Stephanie; Melanson, Edward L; Neuman, Michael R; Sazonov, Edward

    2010-08-01

    Studies of food intake and ingestive behavior in free-living conditions most often rely on self-reporting-based methods that can be highly inaccurate. Methods of Monitoring of Ingestive Behavior (MIB) rely on objective measures derived from chewing and swallowing sequences and thus can be used for unbiased study of food intake with free-living conditions. Our previous study demonstrated accurate detection of food intake in simple models relying on observation of both chewing and swallowing. This article investigates methods that achieve comparable accuracy of food intake detection using only the time series of swallows and thus eliminating the need for the chewing sensor. The classification is performed for each individual swallow rather than for previously used time slices and thus will lead to higher accuracy in mass prediction models relying on counts of swallows. Performance of a group model based on a supervised method (SVM) is compared to performance of individual models based on an unsupervised method (K-means) with results indicating better performance of the unsupervised, self-adapting method. Overall, the results demonstrate that highly accurate detection of intake of foods with substantially different physical properties is possible by an unsupervised system that relies on the information provided by the swallowing alone.

  1. Detection of Food Intake from Swallowing Sequences by Supervised and Unsupervised Methods

    PubMed Central

    Lopez-Meyer, Paulo; Makeyev, Oleksandr; Schuckers, Stephanie; Melanson, Edward L.; Neuman, Michael R.; Sazonov, Edward

    2010-01-01

    Studies of food intake and ingestive behavior in free-living conditions most often rely on self-reporting-based methods that can be highly inaccurate. Methods of Monitoring of Ingestive Behavior (MIB) rely on objective measures derived from chewing and swallowing sequences and thus can be used for unbiased study of food intake with free-living conditions. Our previous study demonstrated accurate detection of food intake in simple models relying on observation of both chewing and swallowing. This article investigates methods that achieve comparable accuracy of food intake detection using only the time series of swallows and thus eliminating the need for the chewing sensor. The classification is performed for each individual swallow rather than for previously used time slices and thus will lead to higher accuracy in mass prediction models relying on counts of swallows. Performance of a group model based on a supervised method (SVM) is compared to performance of individual models based on an unsupervised method (K-means) with results indicating better performance of the unsupervised, self-adapting method. Overall, the results demonstrate that highly accurate detection of intake of foods with substantially different physical properties is possible by an unsupervised system that relies on the information provided by the swallowing alone. PMID:20352335

  2. Laser-only Adaptive Optics Achieves Significant Image Quality Gains Compared to Seeing-limited Observations over the Entire Sky

    NASA Astrophysics Data System (ADS)

    Howard, Ward S.; Law, Nicholas M.; Ziegler, Carl A.; Baranec, Christoph; Riddle, Reed

    2018-02-01

    Adaptive optics laser guide-star systems perform atmospheric correction of stellar wavefronts in two parts: stellar tip-tilt and high-spatial-order laser correction. The requirement of a sufficiently bright guide star in the field-of-view to correct tip-tilt limits sky coverage. In this paper, we show an improvement to effective seeing without the need for nearby bright stars, enabling full sky coverage by performing only laser-assisted wavefront correction. We used Robo-AO, the first robotic AO system, to comprehensively demonstrate this laser-only correction. We analyze observations from four years of efficient robotic operation covering 15000 targets and 42000 observations, each realizing different seeing conditions. Using an autoguider (or a post-processing software equivalent) and the laser to improve effective seeing independent of the brightness of a target, Robo-AO observations show a 39% ± 19% improvement to effective FWHM, without any tip-tilt correction. We also demonstrate that 50% encircled energy performance without tip-tilt correction remains comparable to diffraction-limited, standard Robo-AO performance. Faint-target science programs primarily limited by 50% encircled energy (e.g., those employing integral field spectrographs placed behind the AO system) may see significant benefits to sky coverage from employing laser-only AO.

  3. Comparison of physical examination performance of medical students trained by musculoskeletal versus non-musculoskeletal specialists.

    PubMed

    Melo, Luciano; Schrieber, Leslie; Eyles, Jillian; Deveza, Leticia A; Meneses, Sarah R F; Hunter, David J

    2017-04-01

    To compare the musculoskeletal (MSK) physical examination skills, knowledge acquisition and performance of first-year medical students trained by MSK specialist tutors to students trained by non-MSK specialist tutors, after a 6-week MSK physical examination tutorial program. Twenty-first year medical students took part in the study. They were recruited into two groups, according to their exposure to either an MSK specialist or a non-MSK specialist tutor during their 6-week MSK training block. Knowledge acquisition was measured via a pre- and post-training objective structured clinical examination (OSCE). We assessed students' self-belief and confidence levels regarding their newly acquired skills via a questionnaire. Independent t tests were used to examine mean group differences of OSCE scores and perceived level of confidence. Both groups demonstrated a significant improvement (3.9 and 3.8 points, respectively, on an eight-point scale for shoulder assessment, P < 0.01, 3.3 and 3.5, respectively, on a five-point scale for spine assessment, P < 0.01) in OSCE scores compared to baseline after completing the 6-week MSK physical examination tutorial program. There was no between-group difference in the OSCE scores from pre- to post-training (P = 0.92 for shoulder, P = 0.66 for spine) or for perceived level of confidence in performing a basic MSK examination after training (P = 0.91). Students exposed to MSK specialist tutors did not demonstrate increased skill levels or knowledge in the area of MSK physical examination compared to those receiving the same training under the supervision of non-MSK specialist tutors. Both student groups demonstrated improvement. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  4. Validation of a novel biomarker panel for the detection of ovarian cancer

    PubMed Central

    Leung, Felix; Bernardini, Marcus Q.; Brown, Marshall D.; Zheng, Yingye; Molina, Rafael; Bast, Robert C.; Davis, Gerard; Serra, Stefano; Diamandis, Eleftherios P.; Kulasingam, Vathany

    2016-01-01

    Background Ovarian cancer (OvCa) is the most lethal gynecological malignancy. Our integrated -omics approach to OvCa biomarker discovery has identified kallikrein 6 (KLK6) and folate-receptor 1 (FOLR1) as promising candidates but these markers require further validation. Methods KLK6, FOLR1 CA125 and HE4 were investigated in three independent serum cohorts with a total of 20 healthy controls, 150 benign controls and 216 OvCa patients. The serum biomarker levels were determined by ELISA or automated immunoassay. Results All biomarkers demonstrated elevations in the sera of OvCa patients compared to controls (p<0.01). Overall, CA125 and HE4 displayed the strongest ability (AUC 0.80 and 0.82, respectively) to identify OvCa patients and the addition of HE4 to CA125 improved the sensitivity from 36% to 67% at a set specificity of 95%. As well, the combination of HE4 and FOLR1 was a strong predictor of OvCa diagnosis, displaying comparable sensitivity (65%) to the best performing CA125-based models (67%) at a set specificity of 95%. Conclusions The markers identified through our integrated –omics approach performed similarly to the clinically-approved markers CA125 and HE4. Furthermore, HE4 represents a powerful diagnostic marker for OvCa and should be used more routinely in a clinical setting. Impact The implications of our study are two-fold: (1) we have demonstrated the strengths of HE4 alone and in combination with CA125, lending credence to increasing its usage in the clinic; and (2) we have demonstrated the clinical utility of our integrated –omics approach to identifying novel serum markers with comparable performance to clinical markers. PMID:27448593

  5. A systematic review and meta-analysis of the circulatory, erythrocellular and CSF selenium levels in Alzheimer's disease: A metal meta-analysis (AMMA study-I).

    PubMed

    Reddy, Varikasuvu Seshadri; Bukke, Suman; Dutt, Naveen; Rana, Puneet; Pandey, Arun Kumar

    2017-07-01

    Available studies in the literature on the selenium levels in Alzheimer's disease (AD) are inconsistent with some studies reporting its decrease in the circulation, while others reported an increase or no change as compared to controls. The objective of this study was to perform a meta-analysis of circulatory (plasma/serum and blood), erythrocyte and cerebrospinal fluid (CSF) selenium levels in AD compared controls. We also performed a meta-analysis of the correlation coefficients (r) to demonstrate the associations between selenium and glutathione peroxidase (GPx) in AD patients. All major databases were searched for eligible studies. We included 12 case-control/observational studies reporting selenium concentrations in AD and controls. Pooled-overall effect size as standardized mean difference (SMD) and pooled r-values were generated using Review Manager 5.3 and MedCalc 15.8 software. Random-effects meta-analysis indicated a decrease in circulatory (SMD=-0.44), erythrocellular (SMD=-0.52) and CSF (SMD=-0.14) selenium levels in AD patients compared to controls. Stratified meta-analysis demonstrated that the selenium levels were decreased in both the subgroups with (SMD=-0.55) and without (SMD=-0.37) age matching between AD and controls. Our results also demonstrated a direct association between decreased selenium levels and GPx in AD. This meta-analysis suggests that circulatory selenium concentration is significantly lower in AD patients compared to controls and this decrease in selenium is directly correlated with an important antioxidant enzyme, the GPx, in AD. Copyright © 2017 Elsevier GmbH. All rights reserved.

  6. A comparison of the Injury Severity Score and the Trauma Mortality Prediction Model.

    PubMed

    Cook, Alan; Weddle, Jo; Baker, Susan; Hosmer, David; Glance, Laurent; Friedman, Lee; Osler, Turner

    2014-01-01

    Performance benchmarking requires accurate measurement of injury severity. Despite its shortcomings, the Injury Severity Score (ISS) remains the industry standard 40 years after its creation. A new severity measure, the Trauma Mortality Prediction Model (TMPM), uses either the Abbreviated Injury Scale (AIS) or DRG International Classification of Diseases-9th Rev. (ICD-9) lexicons and may better quantify injury severity compared with ISS. We compared the performance of TMPM with ISS and other measures of injury severity in a single cohort of patients. We included 337,359 patient records with injuries reliably described in both the AIS and the ICD-9 lexicons from the National Trauma Data Bank. Five injury severity measures (ISS, maximum AIS score, New Injury Severity Score [NISS], ICD-9-Based Injury Severity Score [ICISS], TMPM) were computed using either the AIS or ICD-9 codes. These measures were compared for discrimination (area under the receiver operating characteristic curve), an estimate of proximity to a model that perfectly predicts the outcome (Akaike information criterion), and model calibration curves. TMPM demonstrated superior receiver operating characteristic curve, Akaike information criterion, and calibration using either the AIS or ICD-9 lexicons. Calibration plots demonstrate the monotonic characteristics of the TMPM models contrasted by the nonmonotonic features of the other prediction models. Severity measures were more accurate with the AIS lexicon rather than ICD-9. NISS proved superior to ISS in either lexicon. Since NISS is simpler to compute, it should replace ISS when a quick estimate of injury severity is required for AIS-coded injuries. Calibration curves suggest that the nonmonotonic nature of ISS may undermine its performance. TMPM demonstrated superior overall mortality prediction compared with all other models including ISS whether the AIS or ICD-9 lexicons were used. Because TMPM provides an absolute probability of death, it may allow clinicians to communicate more precisely with one another and with patients and families. Disagnostic study, level I; prognostic study, level II.

  7. Demonstration of a plenoptic microscope based on laser optical feedback imaging.

    PubMed

    Glastre, Wilfried; Hugon, Olivier; Jacquin, Olivier; Guillet de Chatellus, Hugues; Lacot, Eric

    2013-03-25

    A new kind of plenoptic imaging system based on Laser Optical Feedback Imaging (LOFI) is presented and is compared to another previously existing device based on microlens array. Improved photometric performances, resolution and depth of field are obtained at the price of a slow point by point scanning. Main properties of plenoptic microscopes such as numerical refocusing on any curved surface or aberrations compensation are both theoretically and experimentally demonstrated with a LOFI-based device.

  8. Standardized UXO Technology Demonstration Site Blind Grid Scoring Record No. 805

    DTIC Science & Technology

    2007-03-01

    and receiver (RX) coils. b. The Tensor Magnetic Gradiometer System ( TMGS ) has been reconfigured to improve its performance compared with the...ALL TEM. The TMGS raw data files consist of an ASCII header with system settings followed by the data in binary format. The GPS positions, EDA...exported in ASCII format. A new data acquisition system for the TMGS will be supplied by the demonstrator. It is controlled by LabVIEW, as is the ALL

  9. Video- Soldering Iron Inserted Through a Film of Water Onboard the International Space Station (ISS)

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Saturday Morning Science, the science of opportunity series of applied experiments and demonstrations, performed aboard the International Space Station (ISS) by Expedition 6 astronaut Dr. Don Pettit, revealed some remarkable findings. In this video, Dr. Pettit demonstrates the result of inserting a soldering iron into a thin film or sheet of water in space. Dr. Pettit makes comparative comments about the differences and similarities of boiling processes in space and on Earth.

  10. Optimization of GaN Nanorod Growth Conditions for Coalescence Overgrowth

    DTIC Science & Technology

    2016-02-04

    GaN core and QW deposition, an NR LED array can be implemented by covering the NRs with a transparent conductor . It has been demonstrated that the...with a transparent conductor . It has been demonstrated that the optical and electrical performances of an NR LED array can be comparable to those of a...a process of buffered oxide etching for removing this SiNx layer on the sidewalls is required before sidewall QW deposition. Nevertheless, the

  11. Systematic review with network meta-analysis: the efficacy of anti-tumour necrosis factor-alpha agents for the treatment of ulcerative colitis.

    PubMed

    Stidham, R W; Lee, T C H; Higgins, P D R; Deshpande, A R; Sussman, D A; Singal, A G; Elmunzer, B J; Saini, S D; Vijan, S; Waljee, A K

    2014-04-01

    Antibodies against tumour necrosis factor-alpha (anti-TNF) are effective therapies in the treatment of ulcerative colitis (UC), but their comparative efficacy is unknown. To perform a network meta-analysis comparing the efficacy of anti-TNF agents in UC. After screening 506 studies, reviewers extracted information on seven studies. Traditional meta-analysis (TMA) was used to compare each anti-TNF agent to placebo. Bayesian network meta-analysis (NMA) was performed to compare the effects of anti-TNF agents to placebo. In addition, sample sizes for comparative efficacy trials were calculated. Compared to placebo, TMA revealed that anti-TNF agents result in a higher likelihood of induction of remission and response (RR: 2.45, 95% CI: 1.72-3.47 and RR: 1.65, 95% CI: 1.37-1.99 respectively) as well as maintenance of remission and response (RR: 2.00, 95% CI: 1.52-2.62 and RR: 1.76, 95% CI: 1.46-2.14 respectively). Individually, infliximab, adalimumab and goliumumab resulted in a higher likelihood of induction and maintenance for both remission and response. NMA found nonsignificant trends in comparisons of the individual agents. The required sample sizes for direct head-to-head trials between infliximab and adalimumab for induction and maintenance are 174 and 204 subjects respectively. This study demonstrates that, compared to placebo, infliximab, adalimumab and golimumab are all effective for the induction and maintenance of remission in ulcerative colitis. However, network meta-analysis demonstrates that no single agent is clinically superior to the others and therefore, other factors such as cost, safety, route of administration and patient preference should dictate our choice of anti-TNF agents. A randomised comparative efficacy trial between infliximab and adalimumab in UC is of practical size and should be performed. © 2014 John Wiley & Sons Ltd.

  12. A comparative analysis of multiple-choice and student performance-task assessment in the high school biology classroom

    NASA Astrophysics Data System (ADS)

    Cushing, Patrick Ryan

    This study compared the performance of high school students on laboratory assessments. Thirty-four high school students who were enrolled in the second semester of a regular biology class or had completed the biology course the previous semester participated in this study. They were randomly assigned to examinations of two formats, performance-task and traditional multiple-choice, from two content areas, using a compound light microscope and diffusion. Students were directed to think-aloud as they performed the assessments. Additional verbal data were obtained during interviews following the assessment. The tape-recorded narrative data were analyzed for type and diversity of knowledge and skill categories, and percentage of in-depth processing demonstrated. While overall mean scores on the assessments were low, elicited statements provided additional insight into student cognition. Results indicated that a greater diversity of knowledge and skill categories was elicited by the two microscope assessments and by the two performance-task assessments. In addition, statements demonstrating in-depth processing were coded most frequently in narratives elicited during clinical interviews following the diffusion performance-task assessment. This study calls for individual teachers to design authentic assessment practices and apply them to daily classroom routines. Authentic assessment should be an integral part of the learning process and not merely an end result. In addition, teachers are encouraged to explicitly identify and model, through think-aloud methods, desired cognitive behaviors in the classroom.

  13. Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure.

    PubMed

    Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark

    2015-01-01

    This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAP ™ Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Mechanical fixation with ETHICON SECURESTRAP ™ Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure.

  14. Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure

    PubMed Central

    Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark

    2015-01-01

    Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAPTM Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. Results. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Conclusions. Mechanical fixation with ETHICON SECURESTRAPTM Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure. PMID:26240834

  15. Validity of the Hum Test, a Simple and Reliable Alternative to the Weber Test.

    PubMed

    Ahmed, Omar H; Gallant, Sara C; Ruiz, Ryan; Wang, Binhuan; Shapiro, William H; Voigt, Erich P

    2018-06-01

    To compare the diagnostic performance of the Hum Test against the Weber Test using pure tone audiometry (PTA) as the "gold standard" comparator. 29 participants with normal hearing of ages 18 to 35 without any history of hearing abnormalities or otologic conditions were enrolled. Subjects underwent three tests (Hum Test, Weber Test, and PTA) across two conditions: with an ear plug in one ear (side randomized) and without ear plugs. When examining the ability of the Hum Test to detect simulated conductive hearing loss (CHL), the test had a sensitivity of 89.7% and specificity of 100% with high pitched humming and 93.1% and 100%, respectively, with low pitched humming. The Weber Test had a sensitivity and specificity of 96.6% and 100%, respectively. McNemar's test demonstrated agreement between the Hum Test, performed with either high pitched ( P = .32) or low pitched ( P = .56) humming, and the Weber Test. Receiver operating characteristic (ROC) curves for the Hum Test (both high and low pitched) and Weber test were compared and demonstrated no statistically significant difference. The Hum Test is comparable to the Weber Test with regards to its sensitivity, specificity, and diagnostic accuracy in assessing new onset unilateral CHL in previously normal hearing subjects.

  16. Talk aloud problem solving: Exploration of acquisition and frequency building in science text

    NASA Astrophysics Data System (ADS)

    Dembek, Ginny

    Discovering new ways to help students attain higher levels of scientific knowledge and to think critically is a national goal (Educate to Innovate campaign). Despite the best intentions, many students struggle to achieve a basic level of science knowledge (NAEP, 2011). The present study examined Talk Aloud Pair Problem Solving and frequency building with five students who were diagnosed with a disability and receive specialized reading instruction in a special education setting. Acquisition was obtained through scripted lessons and frequency building or practice strengthened the student's verbal repertoire making the problem solving process a durable behavior. Overall, students all demonstrated improvements in problem solving performance when compared to baseline. Students became more significantly accurate in performance and maintenance in learning was demonstrated. Generalization probes indicated improvement in student performance. Implications for practice and future research are discussed.

  17. Quench performance and field quality of FNAL twin-aperture 11 T Nb 3Sn dipole model for LHC upgrades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoynev, Stoyan; Andreev, Nikolai; Apollinari, Giorgio

    A 2 m long single-aperture dipole demonstrator and two 1 m long single-aperture models based on Nb 3Sn superconductor have been built and tested at FNAL. The two 1 m long collared coils were then assembled in a twin-aperture Nb 3Sn dipole demonstrator compatible with the LHC main dipole and tested in two thermal cycles. This paper summarizes the quench performance of the FNAL twin-aperture Nb 3Sn 11 T dipole in the temperature range of 1.9-4.5 K. The results of magnetic measurements for one of the two apertures are also presented. Test results are compared to the performance of coilsmore » in a single-aperture configuration. Lastly, a summary of quench propagation studies in both apertures is given.« less

  18. Quench performance and field quality of FNAL twin-aperture 11 T Nb 3Sn dipole model for LHC upgrades

    DOE PAGES

    Stoynev, Stoyan; Andreev, Nikolai; Apollinari, Giorgio; ...

    2016-12-07

    A 2 m long single-aperture dipole demonstrator and two 1 m long single-aperture models based on Nb 3Sn superconductor have been built and tested at FNAL. The two 1 m long collared coils were then assembled in a twin-aperture Nb 3Sn dipole demonstrator compatible with the LHC main dipole and tested in two thermal cycles. This paper summarizes the quench performance of the FNAL twin-aperture Nb 3Sn 11 T dipole in the temperature range of 1.9-4.5 K. The results of magnetic measurements for one of the two apertures are also presented. Test results are compared to the performance of coilsmore » in a single-aperture configuration. Lastly, a summary of quench propagation studies in both apertures is given.« less

  19. Comparative study of Nd:KGW lasers pumped at 808 nm and 877 nm

    NASA Astrophysics Data System (ADS)

    Huang, Ke; Ge, Wen-Qi; Zhao, Tian-Zhuo; He, Jian-Guo; Feng, Chen-Yong; Fan, Zhong-Wei

    2015-10-01

    The laser performance and thermal analysis of Nd:KGW laser continuously pumped by 808 nm and 877 nm are comparatively investigated. Output power of 670 mW and 1587 mW, with nearly TEM00 mode, are achieved respectively at 808 nm pump and 877 nm pump. Meanwhile, a high-power passively Q-switched Nd:KGW/Cr4+:YAG laser pumped at 877 nm is demonstrated. An average output power of 1495 mW is obtained at pump power of 5.22 W while the laser is operating at repetition of 53.17 kHz. We demonstrate that 877 nm diode laser is a more potential pump source for Nd:KGW lasers.

  20. CBESW: sequence alignment on the Playstation 3.

    PubMed

    Wirawan, Adrianto; Kwoh, Chee Keong; Hieu, Nim Tri; Schmidt, Bertil

    2008-09-17

    The exponential growth of available biological data has caused bioinformatics to be rapidly moving towards a data-intensive, computational science. As a result, the computational power needed by bioinformatics applications is growing exponentially as well. The recent emergence of accelerator technologies has made it possible to achieve an excellent improvement in execution time for many bioinformatics applications, compared to current general-purpose platforms. In this paper, we demonstrate how the PlayStation 3, powered by the Cell Broadband Engine, can be used as a computational platform to accelerate the Smith-Waterman algorithm. For large datasets, our implementation on the PlayStation 3 provides a significant improvement in running time compared to other implementations such as SSEARCH, Striped Smith-Waterman and CUDA. Our implementation achieves a peak performance of up to 3,646 MCUPS. The results from our experiments demonstrate that the PlayStation 3 console can be used as an efficient low cost computational platform for high performance sequence alignment applications.

  1. CBESW: Sequence Alignment on the Playstation 3

    PubMed Central

    Wirawan, Adrianto; Kwoh, Chee Keong; Hieu, Nim Tri; Schmidt, Bertil

    2008-01-01

    Background The exponential growth of available biological data has caused bioinformatics to be rapidly moving towards a data-intensive, computational science. As a result, the computational power needed by bioinformatics applications is growing exponentially as well. The recent emergence of accelerator technologies has made it possible to achieve an excellent improvement in execution time for many bioinformatics applications, compared to current general-purpose platforms. In this paper, we demonstrate how the PlayStation® 3, powered by the Cell Broadband Engine, can be used as a computational platform to accelerate the Smith-Waterman algorithm. Results For large datasets, our implementation on the PlayStation® 3 provides a significant improvement in running time compared to other implementations such as SSEARCH, Striped Smith-Waterman and CUDA. Our implementation achieves a peak performance of up to 3,646 MCUPS. Conclusion The results from our experiments demonstrate that the PlayStation® 3 console can be used as an efficient low cost computational platform for high performance sequence alignment applications. PMID:18798993

  2. Comparison of performance and operation of side-by-side integrated fixed-film and conventional activated sludge processes at demonstration scale.

    PubMed

    Stricker, Anne-Emmanuelle; Barrie, Ashley; Maas, Carol L A; Fernandes, William; Lishman, Lori

    2009-03-01

    A full-scale demonstration of an integrated fixed-film activated sludge (IFFAS) process with floating carriers has been conducted in Ontario, Canada, since August 2003. In this study, data collected on-site from July 2005 to December 2006 are analyzed and compared with the performance of a conventional activated sludge train operated in parallel. Both trains received similar loadings and maintained comparable mixed liquor concentrations; however, the IFFAS had 50% more biomass when the attached growth was considered. In the winter, the conventional train operated at the critical solids retention time (SRT) and had fluctuating partial nitrification. The IFFAS nitrified more consistently and had a doubled average capacity. In the summer, the suspended SRT was less limiting, and the benefit of IFFAS for nitrification was marginal. The lessons learned from the operational requirements and challenges of the IFFAS process (air flow, carrier management, and seasonal foaming) are discussed, and design recommendations are proposed for whole plant retrofit.

  3. Experimental analysis of robot-assisted needle insertion into porcine liver.

    PubMed

    Wang, Wendong; Shi, Yikai; Goldenberg, Andrew A; Yuan, Xiaoqing; Zhang, Peng; He, Lijing; Zou, Yingjie

    2015-01-01

    How to improve placement accuracy of needle insertion into liver tissue is of paramount interest to physicians. A robot-assisted system was developed to experimentally demonstrate its advantages in needle insertion surgeries. Experiments of needle insertion into porcine liver tissue were performed with conic tip needle (diameter 8 mm) and bevel tip needle (diameter 1.5 mm) in this study. Manual operation was designed to compare the performance of the presented robot-assisted system. The real-time force curves show outstanding advantages of robot-assisted operation in improving the controllability and stability of needle insertion process by comparing manual operation. The statistics of maximum force and average force further demonstrates robot-assisted operation causes less oscillation. The difference of liver deformation created by manual operation and robot-assisted operation is very low, 1 mm for average deformation and 2 mm for maximum deformation. To conclude, the presented robot-assisted system can improve placement accuracy of needle by stably control insertion process.

  4. Assessment of motor and process skills: assessing client work performance in Belgium.

    PubMed

    Vandamme, Dirk

    2010-01-01

    The aim of this study is to establish whether the Assessment of Motor and Process Skills (AMPS) is an appropriate tool to evaluate the quality of work performance by comparing clients' results on the AMPS with the quality of the skills that they demonstrate on the shop floor. A convenience sample of chronically unemployed (vocationally disabled) participants (N=139) with no formal training who were seeking unskilled work through Jobcentrum West-Vlaanderen (West Flanders Job Centre, Belgium) was used. Results demonstrated that in 75.2% of cases the prediction of employment outcome was correct; it is suggested that an AMPS motor score < 2.5 and a process score < 1.2 is insufficient for regular employment, while a motor score > 3.1 and process score > 1.5 indicates that regular employment is a realistic goal. The quality of the motor skills measured by the AMPS and measured on the shop floor are comparable, but little similarity was found in the measurement of process skills.

  5. Implementation of metal-friendly EAM/FS-type semi-empirical potentials in HOOMD-blue: A GPU-accelerated molecular dynamics software

    NASA Astrophysics Data System (ADS)

    Yang, Lin; Zhang, Feng; Wang, Cai-Zhuang; Ho, Kai-Ming; Travesset, Alex

    2018-04-01

    We present an implementation of EAM and FS interatomic potentials, which are widely used in simulating metallic systems, in HOOMD-blue, a software designed to perform classical molecular dynamics simulations using GPU accelerations. We first discuss the details of our implementation and then report extensive benchmark tests. We demonstrate that single-precision floating point operations efficiently implemented on GPUs can produce sufficient accuracy when compared against double-precision codes, as demonstrated in test simulations of calculations of the glass-transition temperature of Cu64.5Zr35.5, and pair correlation function g (r) of liquid Ni3Al. Our code scales well with the size of the simulating system on NVIDIA Tesla M40 and P100 GPUs. Compared with another popular software LAMMPS running on 32 cores of AMD Opteron 6220 processors, the GPU/CPU performance ratio can reach as high as 4.6. The source code can be accessed through the HOOMD-blue web page for free by any interested user.

  6. Embryo transfer by reproductive endocrinology fellows vs attending physicians: are live birth rates comparable?

    PubMed

    Eaton, Jennifer L; Zhang, Xingqi; Barnes, Randall B

    2014-11-01

    To compare live birth rates following ultrasound-guided embryo transfer (ET) by reproductive endocrinology and infertility fellows versus attending physicians. Women who underwent their first day-3, fresh, nondonor ET between Oct. 1, 2005, and April 1, 2011, at our academic center were included in this retrospective cohort study. Embryos were designated high quality if they had 8 cells, less than 10% fragmentation, and no asymmetry. ET was performed with the afterload technique under ultrasound guidance. Categorical variables were evaluated with the χ(2) test and continuous variables with the Student t test. Logistic regression was performed to assess the relationship between ET physician and live birth rate while adjusting for potential confounders. Seven hundred sixty women underwent ET by an attending physician, and 104 by a fellow. Baseline characteristics were similar between the groups. The live birth rate was 31% following ET by an attending physician, compared with 34% following ET by a fellow (P = .65). Logistic regression adjusting for potential confounders demonstrated no significant association between ET physician and live birth rate. This retrospective study demonstrated no significant difference in live birth rates following ultrasound-guided ET by fellows vs attending physicians at our institution. These data suggest that academic practices using the afterload method and ultrasound guidance can train fellows to perform ET without compromising success rates. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Respiratory muscle endurance after training in athletes and non-athletes: A systematic review and meta-analysis.

    PubMed

    Sales, Ana Tereza do N; Fregonezi, Guilherme A de F; Ramsook, Andrew H; Guenette, Jordan A; Lima, Illia Nadinne D F; Reid, W Darlene

    2016-01-01

    The objectives of this systematic review was to evaluate the effects of respiratory muscle training (RMT) on respiratory muscle endurance (RME) and to determine the RME test that demonstrates the most consistent changes after RMT. Electronic searches were conducted in EMBASE, MEDLINE, COCHRANE CENTRAL, CINHAL and SPORTDiscus. The PEDro scale was used for quality assessment and meta-analysis were performed to compare effect sizes of different RME tests. Twenty studies met the inclusion criteria. Isocapnic hyperpnea training was performed in 40% of the studies. Meta-analysis showed that RMT improves RME in athletes (P = 0.0007) and non-athletes (P = 0.001). Subgroup analysis showed differences among tests; maximal sustainable ventilatory capacity (MSVC) and maximal sustainable threshold loading tests demonstrated significant improvement after RMT (P = 0.007; P = 0.003 respectively) compared to the maximal voluntary ventilation (MVV) (P = 0.11) in athletes whereas significant improvement after RMT was only shown by MSVC in non-athletes. The effect size of MSVC was greater compared to MVV in studies that performed both tests. The meta-analysis results provide evidence that RMT improves RME in athletes and non-athletes and MSVC test that examine endurance over several minutes are more sensitive to improvement after RMT. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Analysis of PCR Thermocycling by Rayleigh-Bénard Convection

    NASA Astrophysics Data System (ADS)

    Sharma, Ruchi; Ugaz, Victor

    2004-03-01

    In previous studies, we demonstrated a novel device employing the circulatory flow field established by Rayleigh-Bénard convection to perform amplification of a 295 base target region from a human genomic DNA template inside a 35 uL cylindrical cavity using the polymerase chain reaction (PCR) [Krishnan, Ugaz & Burns, Science, Vol. 298, 2002, p. 793]. This design eliminates the need for dynamic external temperature control required in conventional thermocyclers that repeatedly heat and cool static sample volumes to denaturation, annealing, and extension temperatures. In this paper, we extend these studies by demonstrating the design and operation of a multiwell convective flow device capable of achieving amplification of a 191 base pair fragment associated with membrane channel proteins M1 and M2 of the influenza-A virus in as little as 15 minutes with performance comparable to a conventional thermocycler. We also study the effect of initial template concentration and observe no degradation in performance over four orders of magnitude of initial template loading dilution, consistent with conventional thermocycler results. These results illustrate the ability of convective flow PCR systems to achieve performance equal to or exceeding conventional thermocycling hardware, and demonstrate their suitability for use in rapid biodetection assays.

  9. Robotic Assisted Microsurgery - RAMS FY'97

    NASA Technical Reports Server (NTRS)

    1997-01-01

    JPL and Microdexterity Systems collaborated to develop new surgical capabilities. They developed a Robot Assisted Microsurgery (RAM) tool for surgeons to use for operating on the eye, ear, brain, and blood vessels with unprecedented dexterity. A surgeon can hold the surgical instrument with motions of 6 degrees of freedom with an accuracy of 25 microns in a 70 cu cm workspace. In 1996 a demonstration was performed to remove a microscopic particle from a simulated eyeball. In 1997, tests were performed at UCLA to compare telerobotics with mechanical operations. In 5 out of 7 tests, the RAM tool performed with a significant improvement of preciseness over mechanical operation. New design features include: (1) amplified forced feedback; (2) simultaneous slave robot instrumentation; (3) index control switch on master handle; and (4) tool control switches. Upgrades include: (1) increase in computational power; and (2) installation of hard disk memory storage device for independent operation and independent operation of forceps. In 1997 a final demonstration was performed using 2 telerobotics simultaneously in a microsurgery suture procedure to close a slit in a thin sheet of latex rubber which extended the capabilities of microsurgery procedures. After completing trials and demonstrations for the FDA the potential benefits for thousands of operations will be exposed.

  10. Determination of awareness in patients with severe brain injury using EEG power spectral analysis

    PubMed Central

    Goldfine, Andrew M.; Victor, Jonathan D.; Conte, Mary M.; Bardin, Jonathan C.; Schiff, Nicholas D.

    2011-01-01

    Objective To determine whether EEG spectral analysis could be used to demonstrate awareness in patients with severe brain injury. Methods We recorded EEG from healthy controls and three patients with severe brain injury, ranging from minimally conscious state (MCS) to locked-in-state (LIS), while they were asked to imagine motor and spatial navigation tasks. We assessed EEG spectral differences from 4 to 24 Hz with univariate comparisons (individual frequencies) and multivariate comparisons (patterns across the frequency range). Results In controls, EEG spectral power differed at multiple frequency bands and channels during performance of both tasks compared to a resting baseline. As patterns of signal change were inconsistent between controls, we defined a positive response in patient subjects as consistent spectral changes across task performances. One patient in MCS and one in LIS showed evidence of motor imagery task performance, though with patterns of spectral change different from the controls. Conclusion EEG power spectral analysis demonstrates evidence for performance of mental imagery tasks in healthy controls and patients with severe brain injury. Significance EEG power spectral analysis can be used as a flexible bedside tool to demonstrate awareness in brain-injured patients who are otherwise unable to communicate. PMID:21514214

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Im, Piljae; Liu, Xiaobing

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan.more » This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.« less

  12. Towards an Operational Definition of Clinical Competency in Pharmacy

    PubMed Central

    2015-01-01

    Objective. To estimate the inter-rater reliability and accuracy of ratings of competence in student pharmacist/patient clinical interactions as depicted in videotaped simulations and to compare expert panelist and typical preceptor ratings of those interactions. Methods. This study used a multifactorial experimental design to estimate inter-rater reliability and accuracy of preceptors’ assessment of student performance in clinical simulations. The study protocol used nine 5-10 minute video vignettes portraying different levels of competency in student performance in simulated clinical interactions. Intra-Class Correlation (ICC) was used to calculate inter-rater reliability and Fisher exact test was used to compare differences in distribution of scores between expert and nonexpert assessments. Results. Preceptors (n=42) across 5 states assessed the simulated performances. Intra-Class Correlation estimates were higher for 3 nonrandomized video simulations compared to the 6 randomized simulations. Preceptors more readily identified high and low student performances compared to satisfactory performances. In nearly two-thirds of the rating opportunities, a higher proportion of expert panelists than preceptors rated the student performance correctly (18 of 27 scenarios). Conclusion. Valid and reliable assessments are critically important because they affect student grades and formative student feedback. Study results indicate the need for pharmacy preceptor training in performance assessment. The process demonstrated in this study can be used to establish minimum preceptor benchmarks for future national training programs. PMID:26089563

  13. Moderate temperature control technology for a lunar base

    NASA Technical Reports Server (NTRS)

    Swanson, Theodore D.; Sridhar, K. R.; Gottmann, Matthias

    1993-01-01

    A parametric analysis is performed to compare different heat pump based thermal control systems for a Lunar Base. Rankine cycle and absorption cycle heat pumps are compared and optimized for a 100 kW cooling load. Variables include the use or lack of an interface heat exchanger, and different operating fluids. Optimization of system mass to radiator rejection temperature is performed. The results indicate a relatively small sensitivity of Rankine cycle system mass to these variables, with optimized system masses of about 6000 kg for the 100 kW thermal load. It is quantitaively demonstrated that absorption based systems are not mass competitive with Rankine systems.

  14. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    NASA Astrophysics Data System (ADS)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  15. Comparing Laser Welding Technologies with Friction Stir Welding for Production of Aluminum Tailor-Welded Blanks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hovanski, Yuri; Carsley, John; Carlson, Blair

    2014-01-15

    A comparison of welding techniques was performed to determine the most effective method for producing aluminum tailor-welded blanks for high volume automotive applications. Aluminum sheet was joined with an emphasis on post weld formability, surface quality and weld speed. Comparative results from several laser based welding techniques along with friction stir welding are presented. The results of this study demonstrate a quantitative comparison of weld methodologies in preparing tailor-welded aluminum stampings for high volume production in the automotive industry. Evaluation of nearly a dozen welding variations ultimately led to down selecting a single process based on post-weld quality and performance.

  16. The Effect on Performance Time and Quality of the Knots after Mono or Bimanual Training of Laparoscopic Intracorporeal Knot Tying according to the Gladiator Rule Technique.

    PubMed

    Asencio, Fernanda de Almeida; Ribeiro, Helizabet Abdala Salomão Ayroza; Romeo, Armando; Wattiez, Arnauld; Ribeiro, Paulo Augusto Galvão Ayroza

    2018-05-18

     To assess whether the monomanual or bimanual training of laparoscopic suture following the same technique may interfere with the knots' performance time and/or quality.  A prospective observational study involving 41 resident students of gynecology/obstetrics and general surgery who attended a laparoscopic suture training for 2 days. The participants were divided into two groups. Group A performed the training using exclusively their dominant hand, and group B performed the training using both hands to tie the intracorporeal knot. All participants followed the same technique, called Romeo Gladiator Rule. At the end of the course, the participants were asked to perform three exercises to assess the time it took them to tie the knots, as well as the quality of the knots.  A comparative analysis of the groups showed that there was no statistically significant difference ( p  = 0.334) between them regarding the length of time to tie one knot. However, when the time to tie 10 consecutive knots was compared, group A was faster than group B ( p  = 0.020). A comparison of the knot loosening average, in millimeters, revealed that the knots made by group B loosened less than those made by group A, but there was no statistically significant difference regarding the number of knots that became untied.  This study demonstrated that the knots from group B showed better quality than those from group A, with lower loosening measures and more strength necessary to untie the knots. The study also demonstrated that group A was faster than B when the time to tie ten consecutive knots was compared. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  17. Palmprint authentication using multiple classifiers

    NASA Astrophysics Data System (ADS)

    Kumar, Ajay; Zhang, David

    2004-08-01

    This paper investigates the performance improvement for palmprint authentication using multiple classifiers. The proposed methods on personal authentication using palmprints can be divided into three categories; appearance- , line -, and texture-based. A combination of these approaches can be used to achieve higher performance. We propose to simultaneously extract palmprint features from PCA, Line detectors and Gabor-filters and combine their corresponding matching scores. This paper also investigates the comparative performance of simple combination rules and the hybrid fusion strategy to achieve performance improvement. Our experimental results on the database of 100 users demonstrate the usefulness of such approach over those based on individual classifiers.

  18. External validation of Global Evaluative Assessment of Robotic Skills (GEARS).

    PubMed

    Aghazadeh, Monty A; Jayaratna, Isuru S; Hung, Andrew J; Pan, Michael M; Desai, Mihir M; Gill, Inderbir S; Goh, Alvin C

    2015-11-01

    We demonstrate the construct validity, reliability, and utility of Global Evaluative Assessment of Robotic Skills (GEARS), a clinical assessment tool designed to measure robotic technical skills, in an independent cohort using an in vivo animal training model. Using a cross-sectional observational study design, 47 voluntary participants were categorized as experts (>30 robotic cases completed as primary surgeon) or trainees. The trainee group was further divided into intermediates (≥5 but ≤30 cases) or novices (<5 cases). All participants completed a standardized in vivo robotic task in a porcine model. Task performance was evaluated by two expert robotic surgeons and self-assessed by the participants using the GEARS assessment tool. Kruskal-Wallis test was used to compare the GEARS performance scores to determine construct validity; Spearman's rank correlation measured interobserver reliability; and Cronbach's alpha was used to assess internal consistency. Performance evaluations were completed on nine experts and 38 trainees (14 intermediate, 24 novice). Experts demonstrated superior performance compared to intermediates and novices overall and in all individual domains (p < 0.0001). In comparing intermediates and novices, the overall performance difference trended toward significance (p = 0.0505), while the individual domains of efficiency and autonomy were significantly different between groups (p = 0.0280 and 0.0425, respectively). Interobserver reliability between expert ratings was confirmed with a strong correlation observed (r = 0.857, 95 % CI [0.691, 0.941]). Experts and participant scoring showed less agreement (r = 0.435, 95 % CI [0.121, 0.689] and r = 0.422, 95 % CI [0.081, 0.0672]). Internal consistency was excellent for experts and participants (α = 0.96, 0.98, 0.93). In an independent cohort, GEARS was able to differentiate between different robotic skill levels, demonstrating excellent construct validity. As a standardized assessment tool, GEARS maintained consistency and reliability for an in vivo robotic surgical task and may be applied for skills evaluation in a broad range of robotic procedures.

  19. Tactile perception and working memory in rats and humans

    PubMed Central

    Fassihi, Arash; Akrami, Athena; Esmaeili, Vahid; Diamond, Mathew E.

    2014-01-01

    Primates can store sensory stimulus parameters in working memory for subsequent manipulation, but until now, there has been no demonstration of this capacity in rodents. Here we report tactile working memory in rats. Each stimulus is a vibration, generated as a series of velocity values sampled from a normal distribution. To perform the task, the rat positions its whiskers to receive two such stimuli, “base” and “comparison,” separated by a variable delay. It then judges which stimulus had greater velocity SD. In analogous experiments, humans compare two vibratory stimuli on the fingertip. We demonstrate that the ability of rats to hold base stimulus information (for up to 8 s) and their acuity in assessing stimulus differences overlap the performance demonstrated by humans. This experiment highlights the ability of rats to perceive the statistical structure of vibrations and reveals their previously unknown capacity to store sensory information in working memory. PMID:24449850

  20. Comparison of precision and speed in laparoscopic and robot-assisted surgical task performance.

    PubMed

    Zihni, Ahmed; Gerull, William D; Cavallo, Jaime A; Ge, Tianjia; Ray, Shuddhadeb; Chiu, Jason; Brunt, L Michael; Awad, Michael M

    2018-03-01

    Robotic platforms have the potential advantage of providing additional dexterity and precision to surgeons while performing complex laparoscopic tasks, especially for those in training. Few quantitative evaluations of surgical task performance comparing laparoscopic and robotic platforms among surgeons of varying experience levels have been done. We compared measures of quality and efficiency of Fundamentals of Laparoscopic Surgery task performance on these platforms in novices and experienced laparoscopic and robotic surgeons. Fourteen novices, 12 expert laparoscopic surgeons (>100 laparoscopic procedures performed, no robotics experience), and five expert robotic surgeons (>25 robotic procedures performed) performed three Fundamentals of Laparoscopic Surgery tasks on both laparoscopic and robotic platforms: peg transfer (PT), pattern cutting (PC), and intracorporeal suturing. All tasks were repeated three times by each subject on each platform in a randomized order. Mean completion times and mean errors per trial (EPT) were calculated for each task on both platforms. Results were compared using Student's t-test (P < 0.05 considered statistically significant). Among novices, greater errors were noted during laparoscopic PC (Lap 2.21 versus Robot 0.88 EPT, P < 0.001). Among expert laparoscopists, greater errors were noted during laparoscopic PT compared with robotic (PT: Lap 0.14 versus Robot 0.00 EPT, P = 0.04). Among expert robotic surgeons, greater errors were noted during laparoscopic PC compared with robotic (Lap 0.80 versus Robot 0.13 EPT, P = 0.02). Among expert laparoscopists, task performance was slower on the robotic platform compared with laparoscopy. In comparisons of expert laparoscopists performing tasks on the laparoscopic platform and expert robotic surgeons performing tasks on the robotic platform, expert robotic surgeons demonstrated fewer errors during the PC task (P = 0.009). Robotic assistance provided a reduction in errors at all experience levels for some laparoscopic tasks, but no benefit in the speed of task performance. Robotic assistance may provide some benefit in precision of surgical task performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Upgraded demonstration vehicle task report

    NASA Technical Reports Server (NTRS)

    Bryant, J.; Hardy, K.; Livingston, R.; Sandberg, J.

    1981-01-01

    Vehicle/battery performance capabilities and interface problems that occurred when upgraded developmental batteries were integrated with upgraded versions of comercially available electric vehicles were investigated. Developmental batteries used included nickel zinc batteries, a nickel iron battery, and an improved lead acid battery. Testing of the electric vehicles and upgraded batteries was performed in the complete vehicle system environment to characterize performance and identify problems unique to the vehicle/battery system. Constant speed tests and driving schedule range tests were performed on a chassis dynamometer. The results from these tests of the upgraded batteries and vehicles were compared to performance capabilities for the same vehicles equipped with standard batteries.

  2. Revisiting the Boeing B-47 and the Avro Vulcan with implications on aircraft design today

    NASA Astrophysics Data System (ADS)

    van Seeters, Philip A.

    This project compares the cruise mission performance of the historic Boeing B-47 and Avro Vulcan. The author aims to demonstrate that despite superficial similarities, these aircraft perform quite differently away from their intended design points. The investigation uses computer aided design software, and an aircraft sizing program to generate digital models of both airplanes. Subsequent simulations of various missions quantify the performance mainly in terms of fuel efficiency, and productivity. Based on this comparison, the efforts conclude that these aircraft perform indeed differently, and that a performance comparison based on a design mission alone, is insufficient.

  3. Upper limb performance and the structuring of joint movement in teenagers with cerebral palsy: the reciprocal role of task demands and action capabilities.

    PubMed

    Figueiredo, Priscilla Rezende Pereira; Silva, Paula Lanna; Avelar, Bruna Silva; da Fonseca, Sérgio Teixeira; Bootsma, Reinoud J; Mancini, Marisa Cotta

    2015-04-01

    Individuals with unilateral cerebral palsy (CP) demonstrate reduced performance in upper limb tasks compared to typically developing (TD) peers. We examined whether task conditions modify differences between teenagers with and without CP during a reciprocal aiming task. Twenty teenagers (nine CP and 11 TD) moved a pointer between two targets as fast as possible without missing a target. Task conditions were manipulated by changing the targets' size, by modifying the inertial properties of the pointer and by varying the upper limb used to perform the task (preferred/non-affected and non-preferred/affected upper limbs). While compared to TD peers, CP teenagers exhibited lower performance (longer movement times). Such differences were attenuated when the task was performed with the preferred upper limb and when accuracy requirements were less stringent. CP teenagers were not differentially affected by the pointer inertia manipulation. Task conditions not only affected performance but also joint kinematics. CP teenagers revealed less movement at the elbow and more movement at the shoulder when performing the task with their less skilled upper limb. However, both CP and TD teenagers demonstrated a larger contribution of trunk movement when facing more challenging task conditions. The overall pattern of results indicated that the joint kinematics employed by individuals with unilateral CP constituted adaptive responses to task requirements. Thus, the explanation of the effects of unilateral CP on upper limb behavior needs to go beyond a context-indifferent manifestation of the brain injury to include the interaction between task demands and action capabilities.

  4. Assessing technical performance in differential gene expression experiments with external spike-in RNA control ratio mixtures.

    PubMed

    Munro, Sarah A; Lund, Steven P; Pine, P Scott; Binder, Hans; Clevert, Djork-Arné; Conesa, Ana; Dopazo, Joaquin; Fasold, Mario; Hochreiter, Sepp; Hong, Huixiao; Jafari, Nadereh; Kreil, David P; Łabaj, Paweł P; Li, Sheng; Liao, Yang; Lin, Simon M; Meehan, Joseph; Mason, Christopher E; Santoyo-Lopez, Javier; Setterquist, Robert A; Shi, Leming; Shi, Wei; Smyth, Gordon K; Stralis-Pavese, Nancy; Su, Zhenqiang; Tong, Weida; Wang, Charles; Wang, Jian; Xu, Joshua; Ye, Zhan; Yang, Yong; Yu, Ying; Salit, Marc

    2014-09-25

    There is a critical need for standard approaches to assess, report and compare the technical performance of genome-scale differential gene expression experiments. Here we assess technical performance with a proposed standard 'dashboard' of metrics derived from analysis of external spike-in RNA control ratio mixtures. These control ratio mixtures with defined abundance ratios enable assessment of diagnostic performance of differentially expressed transcript lists, limit of detection of ratio (LODR) estimates and expression ratio variability and measurement bias. The performance metrics suite is applicable to analysis of a typical experiment, and here we also apply these metrics to evaluate technical performance among laboratories. An interlaboratory study using identical samples shared among 12 laboratories with three different measurement processes demonstrates generally consistent diagnostic power across 11 laboratories. Ratio measurement variability and bias are also comparable among laboratories for the same measurement process. We observe different biases for measurement processes using different mRNA-enrichment protocols.

  5. Does virtual reality simulation have a role in training trauma and orthopaedic surgeons?

    PubMed

    Bartlett, J D; Lawrence, J E; Stewart, M E; Nakano, N; Khanduja, V

    2018-05-01

    Aims The aim of this study was to assess the current evidence relating to the benefits of virtual reality (VR) simulation in orthopaedic surgical training, and to identify areas of future research. Materials and Methods A literature search using the MEDLINE, Embase, and Google Scholar databases was performed. The results' titles, abstracts, and references were examined for relevance. Results A total of 31 articles published between 2004 and 2016 and relating to the objective validity and efficacy of specific virtual reality orthopaedic surgical simulators were identified. We found 18 studies demonstrating the construct validity of 16 different orthopaedic virtual reality simulators by comparing expert and novice performance. Eight studies have demonstrated skill acquisition on a simulator by showing improvements in performance with repeated use. A further five studies have demonstrated measurable improvements in operating theatre performance following a period of virtual reality simulator training. Conclusion The demonstration of 'real-world' benefits from the use of VR simulation in knee and shoulder arthroscopy is promising. However, evidence supporting its utility in other forms of orthopaedic surgery is lacking. Further studies of validity and utility should be combined with robust analyses of the cost efficiency of validated simulators to justify the financial investment required for their use in orthopaedic training. Cite this article: Bone Joint J 2018;100-B:559-65.

  6. Attention and reach-to-grasp movements in Parkinson's disease.

    PubMed

    Lu, Cathy; Bharmal, Aamir; Kiss, Zelma H; Suchowersky, Oksana; Haffenden, Angela M

    2010-08-01

    The role of attention in grasping movements directed at common objects has not been examined in Parkinson's disease (PD), though these movements are critical to activities of daily living. Our primary objective was to determine whether patients with PD demonstrate automaticity in grasping movements directed toward common objects. Automaticity is assumed when tasks can be performed with little or no interference from concurrent tasks. Grasping performance in three patient groups (newly diagnosed, moderate, and advanced/surgically treated PD) on and off of their medication or deep brain stimulation was compared to performance in an age-matched control group. Automaticity was demonstrated by the absence of a decrement in grasping performance when attention was consumed by a concurrent spatial-visualization task. Only the control group and newly diagnosed PD group demonstrated automaticity in their grasping movements. The moderate and advanced PD groups did not demonstrate automaticity. Furthermore, the well-known effects of pharmacotherapy and surgical intervention on movement speed and muscle activation patterns did not appear to reduce the impact of attention-demanding tasks on grasping movements in those with moderate to advanced PD. By the moderate stage of PD, grasping is an attention-demanding process; this change is not ameliorated by dopaminergic or surgical treatments. These findings have important implications for activities of daily living, as devoting attention to the simplest of daily tasks would interfere with complex activities and potentially exacerbate fatigue.

  7. Community Health Centers and Private Practice Performance on Ambulatory Care Measures

    PubMed Central

    Goldman, L. Elizabeth; Chu, Philip W.; Tran, Huong; Stafford, Randall S.

    2013-01-01

    Background The 2010 Affordable Care Act relies on Federally Qualified Health Centers (FQHC) and FQHC look-alikes (look-alikes) to provide care for newly insured patients, but ties increased funding to demonstrated quality and efficiency. Purpose To compare FQHC and look-alike physician performance with private practice primary care physicians (PCPs) on ambulatory care quality measures. Methods The study was a cross-sectional analysis of visits in the 2006–2008 National Ambulatory Medical Care Survey. Performance of FQHCs and Look-alikes on 18 quality measures was compared with private practice PCPs. Data analysis was completed in 2011. Results Compared to private practice PCPs, FQHCs and look-alikes performed better on 6 measures (p<0.05), worse on diet counseling in at-risk adolescents (26 % vs. 36%, p=0.05), and no differently on 11 measures. Higher performance occurred in: ACE inhibitors use for congestive heart failure (51% vs. 37%, p=0.004); aspirin use in coronary artery disease (CAD) (57% vs. 44%, p=0.004); beta blocker use for CAD (59% vs. 47%, p=0.01); no use of benzodiazepines in depression (91% vs. 84%, p=0.008); blood pressure screening (90% vs. 86%, p<0.001); and screening electrocardiogram (EKG) avoidance in low-risk patients (99% vs. 93%, p<0.001). Adjusting for patient characteristics yielded similar results except private practice PCPs no longer performed better on any measures. Conclusions FQHCs and look-alikes demonstrated equal or better performance than private practice primary care physicians on select quality measures despite serving patients with more chronic disease and socioeconomic complexity. These findings can provide policymakers with some reassurance as to the quality of chronic disease and preventive care at Federally Qualified Health Centers and Federally Qualified Health Center look-alikes, as they plan to use these health centers to serve 20 million newly insured individuals. PMID:22813678

  8. Using the weighted area under the net benefit curve for decision curve analysis.

    PubMed

    Talluri, Rajesh; Shete, Sanjay

    2016-07-18

    Risk prediction models have been proposed for various diseases and are being improved as new predictors are identified. A major challenge is to determine whether the newly discovered predictors improve risk prediction. Decision curve analysis has been proposed as an alternative to the area under the curve and net reclassification index to evaluate the performance of prediction models in clinical scenarios. The decision curve computed using the net benefit can evaluate the predictive performance of risk models at a given or range of threshold probabilities. However, when the decision curves for 2 competing models cross in the range of interest, it is difficult to identify the best model as there is no readily available summary measure for evaluating the predictive performance. The key deterrent for using simple measures such as the area under the net benefit curve is the assumption that the threshold probabilities are uniformly distributed among patients. We propose a novel measure for performing decision curve analysis. The approach estimates the distribution of threshold probabilities without the need of additional data. Using the estimated distribution of threshold probabilities, the weighted area under the net benefit curve serves as the summary measure to compare risk prediction models in a range of interest. We compared 3 different approaches, the standard method, the area under the net benefit curve, and the weighted area under the net benefit curve. Type 1 error and power comparisons demonstrate that the weighted area under the net benefit curve has higher power compared to the other methods. Several simulation studies are presented to demonstrate the improvement in model comparison using the weighted area under the net benefit curve compared to the standard method. The proposed measure improves decision curve analysis by using the weighted area under the curve and thereby improves the power of the decision curve analysis to compare risk prediction models in a clinical scenario.

  9. Comparative validity of MMPI-2 and MCMI-II personality disorder classifications.

    PubMed

    Wise, E A

    1996-06-01

    Minnesota Multiphasic Personality Inventory-2 (MMPI-2) overlapping and nonoverlapping scales were demonstrated to perform comparably to their original MMPI forms. They were then evaluated for convergent and discriminant validity with the Million Clinical Multiaxial Inventory-II (MCMI-II) personality disorder scales. The MMPI-2 and MCMI-II personality disorder scales demonstrated convergent and discriminant coefficients similar to their original forms. However, the MMPI-2 personality scales classified significantly more of the sample as Dramatic, whereas the MCMI-II diagnosed more of the sample as Anxious. Furthermore, single-scale and 2-point code type classification rates were quite low, indicating that at the level of the individual, the personality disorder scales are not measuring comparable constructs. Hence, each instrument is providing similar and unique information, justifying their continued use together for the purpose of diagnosing personality disorders.

  10. Parametric and experimental analysis using a power flow approach

    NASA Technical Reports Server (NTRS)

    Cuschieri, J. M.

    1990-01-01

    A structural power flow approach for the analysis of structure-borne transmission of vibrations is used to analyze the influence of structural parameters on transmitted power. The parametric analysis is also performed using the Statistical Energy Analysis approach and the results are compared with those obtained using the power flow approach. The advantages of structural power flow analysis are demonstrated by comparing the type of results that are obtained by the two analytical methods. Also, to demonstrate that the power flow results represent a direct physical parameter that can be measured on a typical structure, an experimental study of structural power flow is presented. This experimental study presents results for an L shaped beam for which an available solution was already obtained. Various methods to measure vibrational power flow are compared to study their advantages and disadvantages.

  11. Design and evaluation of a miniature laser speckle imaging device to assess gingival health

    PubMed Central

    Regan, Caitlin; White, Sean M.; Yang, Bruce Y.; Takesh, Thair; Ho, Jessica; Wink, Cherie; Wilder-Smith, Petra; Choi, Bernard

    2016-01-01

    Abstract. Current methods used to assess gingivitis are qualitative and subjective. We hypothesized that gingival perfusion measurements could provide a quantitative metric of disease severity. We constructed a compact laser speckle imaging (LSI) system that could be mounted in custom-made oral molds. Rigid fixation of the LSI system in the oral cavity enabled measurement of blood flow in the gingiva. In vitro validation performed in controlled flow phantoms demonstrated that the compact LSI system had comparable accuracy and linearity compared to a conventional bench-top LSI setup. In vivo validation demonstrated that the compact LSI system was capable of measuring expected blood flow dynamics during a standard postocclusive reactive hyperemia and that the compact LSI system could be used to measure gingival blood flow repeatedly without significant variation in measured blood flow values (p<0.05). Finally, compact LSI system measurements were collected from the interdental papilla of nine subjects and compared to a clinical assessment of gingival bleeding on probing. A statistically significant correlation (ρ=0.53; p<0.005) was found between these variables, indicating that quantitative gingival perfusion measurements performed using our system may aid in the diagnosis and prognosis of periodontal disease. PMID:27787545

  12. Design and evaluation of a miniature laser speckle imaging device to assess gingival health

    NASA Astrophysics Data System (ADS)

    Regan, Caitlin; White, Sean M.; Yang, Bruce Y.; Takesh, Thair; Ho, Jessica; Wink, Cherie; Wilder-Smith, Petra; Choi, Bernard

    2016-10-01

    Current methods used to assess gingivitis are qualitative and subjective. We hypothesized that gingival perfusion measurements could provide a quantitative metric of disease severity. We constructed a compact laser speckle imaging (LSI) system that could be mounted in custom-made oral molds. Rigid fixation of the LSI system in the oral cavity enabled measurement of blood flow in the gingiva. In vitro validation performed in controlled flow phantoms demonstrated that the compact LSI system had comparable accuracy and linearity compared to a conventional bench-top LSI setup. In vivo validation demonstrated that the compact LSI system was capable of measuring expected blood flow dynamics during a standard postocclusive reactive hyperemia and that the compact LSI system could be used to measure gingival blood flow repeatedly without significant variation in measured blood flow values (p<0.05). Finally, compact LSI system measurements were collected from the interdental papilla of nine subjects and compared to a clinical assessment of gingival bleeding on probing. A statistically significant correlation (ρ=0.53 p<0.005) was found between these variables, indicating that quantitative gingival perfusion measurements performed using our system may aid in the diagnosis and prognosis of periodontal disease.

  13. Semi-conducting single-walled carbon nanotubes are detrimental when compared to metallic single-walled carbon nanotubes for electrochemical applications.

    PubMed

    Dong, Qi; Nasir, Muhammad Zafir Mohamad; Pumera, Martin

    2017-10-18

    As-synthetized single walled carbon nanotubes (SWCNTs) contain both metallic and semiconducting nanotubes. For the electronics, it is desirable to separate semiconducting SWCNTs (s-SWCNTs) from the metallic ones as s-SWCNTs provide desirable electronic properties. Here we test whether ultrapure semi-conducting single-walled carbon nanotubes (s-SWCNTs) provide advantageous electrochemical properties over the as prepared SWCNTs which contain a mixture of semiconducting and metallic CNTs. We test them as a transducer platform which enhanced the detection of target analytes (ascorbic acid, dopamine, uric acid) when compared to a bare glassy carbon (GC) electrode. Despite that, the two materials exhibit significantly different electrochemical properties and performances. A mixture of m-SWCNTs and s-SWCNTs demonstrated superior performance over ultrapure s-SWCNTs with greater peak currents and pronounced shift in peak potentials to lower values in cyclic and differential pulse voltammetry for the detection of target analytes. The mixture of m- and s-SWCNTs displayed about a 4 times improved heterogeneous electron transfer rate as compared to bare GC and a 2 times greater heterogeneous electron transfer rate than s-SWCNTs, demonstrating that ultrapure SWCNTs do not provide any major enhancement over the as prepared SWCNTs.

  14. Teaching binocular indirect ophthalmoscopy to novice residents using an augmented reality simulator.

    PubMed

    Rai, Amandeep S; Rai, Amrit S; Mavrikakis, Emmanouil; Lam, Wai Ching

    2017-10-01

    To compare the traditional teaching approach of binocular indirect ophthalmoscopy (BIO) to the EyeSI augmented reality (AR) BIO simulator. Prospective randomized control trial. 28 post-graduate year one (PGY1) ophthalmology residents. Residents were recruited at the 2012 Toronto Ophthalmology Residents Introductory Course (TORIC). 15 were randomized to conventional teaching (Group 1), and 13 to augmented reality simulator training (Group 2). 3 vitreoretinal fellows were enrolled to serve as experts. Evaluations were completed on the simulator, with 3 tasks, and outcome measures were total raw score, total time elapsed, and performance. Following conventional training, Group 1 residents were outperformed by vitreoretinal fellows with respect to all 3 outcome measures. Following AR training, Group 2 residents demonstrated superior total scores and performance compared to Group 1 residents. Once the Group 1 residents also completed the AR BIO training, there was a significant improvement compared to their baseline scores, and were now on par with Group 2 residents. This study provides construct validity for the EyeSI AR BIO simulator and demonstrates that it may be superior to conventional BIO teaching for novice ophthalmology residents. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  15. Green Propellant Infusion Mission

    NASA Image and Video Library

    2013-07-09

    Dr. Michael Gazarik, Associate Administrator, NASA Space Technology Mission Directorate, answers a reporter's question at a Green Propellant Infusion Mission press conference at the Reserve Officers Association, Tuesday, July 9, 2013 in Washington. The NASA GPIM program, led by Ball Aerospace in conjunction with Aerojet Rocketdyne, is demonstrating a high-performance "green" fuel in space. The propellant used on this mission offers nearly 50 percent better performance when compared to traditional hydrazine. Photo Credit: (NASA/Carla Cioffi)

  16. Linear Self-Referencing Techiques for Short-Optical-Pulse Characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorrer, C.; Kang, I.

    2008-04-04

    Linear self-referencing techniques for the characterization of the electric field of short optical pulses are presented. The theoretical and practical advantages of these techniques are developed. Experimental implementations are described, and their performance is compared to the performance of their nonlinear counterparts. Linear techniques demonstrate unprecedented sensitivity and are a perfect fit in many domains where the precise, accurate measurement of the electric field of an optical pulse is required.

  17. The Impact of Nursing Home Pay-for-Performance on Quality and Medicare Spending: Results from the Nursing Home Value-Based Purchasing Demonstration.

    PubMed

    Grabowski, David C; Stevenson, David G; Caudry, Daryl J; O'Malley, A James; Green, Lisa H; Doherty, Julia A; Frank, Richard G

    2017-08-01

    To evaluate the impact of the Nursing Home Value-Based Purchasing demonstration on quality of care and Medicare spending. Administrative and qualitative data from Arizona, New York, and Wisconsin nursing homes over the base-year (2008-2009) and 3-year (2009-2012) demonstration period. Nursing homes were randomized to the intervention in New York, while the comparison facilities were constructed via propensity score matching in Arizona and Wisconsin. We used a difference-in-difference analysis to compare outcomes across the base-year relative to outcomes in each of the three demonstration years. To provide context and assist with interpretation of results, we also interviewed staff members at participating facilities. Medicare savings were observed in Arizona in the first year only and Wisconsin for the first 2 years; no savings were observed in New York. The demonstration did not systematically impact any of the quality measures. Discussions with nursing home administrators suggested that facilities made few, if any, changes in response to the demonstration, leading us to conclude that the observed savings likely reflected regression to the mean rather than true savings. The Federal nursing home pay-for-performance demonstration had little impact on quality or Medicare spending. © Health Research and Educational Trust.

  18. Friends as Coworkers: Research Review and Classroom Implications.

    ERIC Educational Resources Information Center

    Zajac, Robert J.; Hartup, Willard W.

    1997-01-01

    Provides evidence that benefits occur when friends, compared with nonfriends, are coworkers on cognitive tasks. Notes meta-analysis which found superior performance was demonstrated in the areas of seeking scarce resources, problem solving, creative activity, and reaching consensus. Argues teachers should consider giving students the opportunity…

  19. Development of space-stable thermal control coatings for use on large space vehicles

    NASA Technical Reports Server (NTRS)

    Gilligan, J. E.; Harada, Y.

    1976-01-01

    The potential of zinc orthotitanate as a pigment for spacecraft thermal control was demonstrated. The properties and performance of pigments prepared by solid state, coprecipitation, and mixed oxalate methods were compared. Environmental tests and subsequent spectral analysis were given primary emphasis.

  20. Generalizable, Electroless, Template-Assisted Synthesis and Electrocatalytic Mechanistic Understanding of Perovskite LaNiO 3 Nanorods as Viable, Supportless Oxygen Evolution Reaction Catalysts in Alkaline Media

    DOE PAGES

    McBean, Coray L.; Liu, Haiqing; Scofield, Megan E.; ...

    2017-07-17

    We present that the oxygen evolution reaction (OER) is a key reaction for water electrolysis cells and air-powered battery applications. However, conventional metal oxide catalysts, used for high-performing OER, tend to incorporate comparatively expensive and less abundant precious metals such as Ru and Ir, and, moreover, suffer from poor stability. To attempt to mitigate for all of these issues, we have prepared one-dimensional (1D) OER-active perovskite nanorods using a unique, simple, generalizable, and robust method. Significantly, our work demonstrates the feasibility of a novel electroless, seedless, surfactant-free, wet solution-based protocol for fabricating “high aspect ratio” LaNiO 3 and LaMnO 3more » nanostructures. As the main focus of our demonstration of principle, we prepared as-synthesized LaNiO 3 rods and correlated the various temperatures at which these materials were annealed with their resulting OER performance. In addition, we observed generally better OER performance for samples prepared with lower annealing temperatures. Specifically, when annealed at 600 °C, in the absence of a conventional conductive carbon support, our as-synthesized LaNiO 3 rods not only evinced (i) a reasonable level of activity toward OER but also displayed (ii) an improved stability, as demonstrated by chronoamperometric measurements, especially when compared with a control sample of commercially available (and more expensive) RuO 2.« less

  1. Common Femoral Artery Access on YouTube: What Practices are Being Shown and Who is Delivering the Message?

    PubMed

    Pitcher, Grayson S; Newton, Daniel H; Amendola, Michael F

    Novice learners are increasingly turning to YouTube as a learning resource for surgical procedures. One example of such a procedure is common femoral artery puncture and sheath placement. Practitioners in several specialties perform this procedure to access the arterial system for angiography and intervention. We set forth to compare the techniques demonstrated on YouTube by the various specialists, as well as compare each specialty׳s prevalence on this website. YouTube (www.youtube.com) was accessed in December 2015 at multiple time points with a cleared-cache web browser for the keyword search categories: "femoral artery access," "femoral access," and "angiography access." The top 500 videos from each of these keyword searches were analyzed. Videos were categorized by practitioner specialty, technique, duration of video, age of video, and total views. Videos with clear demonstration of femoral artery access were included in the analysis. All industry videos were excluded from the analysis. Categorical variables were compared using Fisher׳s exact test, and continuous variables were compared with the Student׳s t-test. A total of 2460, 4680 and 1800 videos were found for each keyword search, respectively. Of these, 33 videos clearly demonstrated femoral artery access technique. Vascular specialists, compared to interventional cardiology and radiology, had fewer videos (n = 4 vs. 14) and older videos (3.5 ± 2.1y vs. 2.25 ± 0.5y, p < 0.05). The vascular specialists demonstrated ultrasound-guided access, while interventional cardiology predominantly demonstrated landmark-guided access (p < 0.05). Although YouTube and other online resources are being used by novice learners, vascular specialists are underrepresented for femoral artery access, a foundational vascular procedure. Other practitioners demonstrate videos with landmark-guided access and rarely demonstrate ultrasound use. As recognized vascular experts, vascular surgeons should improve their visibility in online learning resources. Copyright © 2017 Association of Program Directors in Surgery. All rights reserved.

  2. Return-to-Play and Performance Outcomes of Professional Athletes in North America After Hip Arthroscopy From 1999 to 2016.

    PubMed

    Schallmo, Michael S; Fitzpatrick, Thomas H; Yancey, Hunter B; Marquez-Lara, Alejandro; Luo, T David; Stubbs, Allston J

    2018-05-01

    The effect of hip arthroscopy on athletic performance compared with preinjury levels for professional athletes in different sports remains unknown. In addition, while return rates have been reported for professional baseball, football, and hockey players, return rates have not been reported for professional basketball players. Professional athletes in 4 major North American sports would be able to return to their sport and preoperative level of performance at a high rate after arthroscopic hip surgery. Descriptive epidemiology study. Major League Baseball (MLB), National Basketball Association (NBA), National Football League (NFL), and National Hockey League (NHL) athletes who underwent hip arthroscopy were identified through a previously reported protocol based on public sources. Successful return to play (RTP) was defined as returning for at least 1 professional regular season game after surgery. Performance scores were calculated by use of previously established scoring systems. Each player served as his own control, with the season prior to surgery defined as baseline. To make comparisons across sports, the authors adjusted for expected season and career length differences between sports and calculated percentage changes in performance. The authors identified 227 procedures performed on 180 professional athletes between 1999 and 2016. Successful RTP was achieved in 84.6% (192/227) of the procedures. Compared with all other athletes, NBA athletes returned at a similar rate (85.7%, P ≥ .999). NFL offensive linemen returned at a significantly lower rate than all other athletes (61.1%, P = .010). NHL athletes returned at a significantly higher rate than all other athletes (91.8%, P = .048) and demonstrated significantly decreased performance during postoperative season 1 compared with baseline (-35.1%, P = .002). Lead leg surgery for MLB athletes (batting stance for hitters, pitching stance for pitchers) resulted in a 12.7% reduction in hitter performance score ( P = .041), a 1.3% reduction in pitcher fastball velocity ( P = .004), and a 60.7% reduction in pitch count ( P = .007) one season after surgery compared with baseline. Players in nearly every sport demonstrated significant reductions in game participation after surgery. This study supports the hypothesis that hip arthroscopy in professional athletes is associated with excellent rates of return at the professional level. However, postoperative performance outcomes varied based on sport and position.

  3. Simulation-trained junior residents perform better than general surgeons on advanced laparoscopic cases.

    PubMed

    Boza, Camilo; León, Felipe; Buckel, Erwin; Riquelme, Arnoldo; Crovari, Fernando; Martínez, Jorge; Aggarwal, Rajesh; Grantcharov, Teodor; Jarufe, Nicolás; Varas, Julián

    2017-01-01

    Multiple simulation training programs have demonstrated that effective transfer of skills can be attained and applied into a more complex scenario, but evidence regarding transfer to the operating room is limited. To assess junior residents trained with simulation performing an advanced laparoscopic procedure in the OR and compare results to those of general surgeons without simulation training and expert laparoscopic surgeons. Experimental study: After a validated 16-session advanced laparoscopy simulation training program, junior trainees were compared to general surgeons (GS) with no simulation training and expert bariatric surgeons (BS) in performing a stapled jejuno-jejunostomy (JJO) in the OR. Global rating scale (GRS) and specific rating scale scores, operative time and the distance traveled by both hands measured with a tracking device, were assessed. In addition, all perioperative and immediate postoperative morbidities were registered. Ten junior trainees, 12 GS and 5 BS experts were assessed performing a JJO in the OR. All trainees completed the entire JJO in the OR without any takeovers by the BS. Six (50 %) BS takeovers took place in the GS group. Trainees had significantly better results in all measured outcomes when compared to GS with considerable higher GRS median [19.5 (18.8-23.5) vs. 12 (9-13.8) p < 0.001] and lower operative time. One morbidity was registered; a patient in the trainees group was readmitted at postoperative day 10 for mechanical ileus that resolved with medical treatment. This study demonstrated transfer of advanced laparoscopic skills acquired through a simulated training program in novice surgical residents to the OR.

  4. Evaluation residual moisture in lithium-ion battery electrodes and its effect on electrode performance

    DOE PAGES

    Li, Jianlin; Daniel, Claus; Wood, III, David L.; ...

    2016-01-11

    Removing residual moisture in lithium-ion battery electrodes is essential for desired electrochemical performance. In this manuscript, the residual moisture in LiNi 0.5Mn 0.3Co 0.2O 2 cathodes produced by conventional solvent-based and aqueous processing is characterized and compared. The electrochemical performance has also been investigated for various residual moisture contents. As a result, it has been demonstrated that the residual moisture lowers the first cycle coulombic efficiency, but its effect on short term cycle life is insignificant.

  5. Comparison between measured turbine stage performance and the predicted performance using quasi-3D flow and boundary layer analyses

    NASA Technical Reports Server (NTRS)

    Boyle, R. J.; Haas, J. E.; Katsanis, T.

    1984-01-01

    A method for calculating turbine stage performance is described. The usefulness of the method is demonstrated by comparing measured and predicted efficiencies for nine different stages. Comparisons are made over a range of turbine pressure ratios and rotor speeds. A quasi-3D flow analysis is used to account for complex passage geometries. Boundary layer analyses are done to account for losses due to friction. Empirical loss models are used to account for incidence, secondary flow, disc windage, and clearance losses.

  6. TCP Performance Enhancement Over Iridium

    NASA Technical Reports Server (NTRS)

    Torgerson, Leigh; Hutcherson, Joseph; McKelvey, James

    2007-01-01

    In support of iNET maturation, NASA-JPL has collaborated with NASA-Dryden to develop, test and demonstrate an over-the-horizon vehicle-to-ground networking capability, using Iridium as the vehicle-to-ground communications link for relaying critical vehicle telemetry. To ensure reliability concerns are met, the Space Communications Protocol Standards (SCPS) transport protocol was investigated for its performance characteristics in this environment. In particular, the SCPS-TP software performance was compared to that of the standard Transmission Control Protocol (TCP) over the Internet Protocol (IP). This paper will report on the results of this work.

  7. Iodine Propulsion Advantages for Low Cost Mission Applications and the Iodine Satellite (ISAT) Technology Demonstration

    NASA Technical Reports Server (NTRS)

    Dankanich, John W.; Schumacher, Daniel M.

    2015-01-01

    The NASA Marshall Space Flight Center Science and Technology Office is continuously exploring technology options to increase performance or reduce cost and risk to future NASA missions including science and exploration. Electric propulsion is a prevalent technology known to reduce mission costs by reduction in launch costs and spacecraft mass through increased post launch propulsion performance. The exploration of alternative propellants for electric propulsion continues to be of interest to the community. Iodine testing has demonstrated comparable performance to xenon. However, iodine has a higher storage density resulting in higher ?V capability for volume constrained systems. Iodine's unique properties also allow for unpressurized storage yet sublimation with minimal power requirements to produce required gas flow rates. These characteristics make iodine an ideal propellant for secondary spacecraft. A range of mission have been evaluated with a focus on low-cost applications. Results highlight the potential for significant cost reduction over state of the art. Based on the potential, NASA has been developing the iodine Satellite for a near-term iodine Hall propulsion technology demonstration. Mission applications and progress of the iodine Satellite project are presented.

  8. Filament-reinforced metal composite pressure vessel evaluation and performance demonstration

    NASA Technical Reports Server (NTRS)

    Landes, R. E.

    1976-01-01

    Two different Kevlar-49 filament-reinforced metal sphere designs were developed, and six vessels of each type were fabricated and subjected to fatigue cycling, sustained loading, and hydrostatic burst. The 61 cm (24 inch) diameter Kevlar-49/cryoformed 301 stainless steel pressure vessels demonstrated the required pressure cycle capability, burst factor of safety, and a maximum pressure times volume divided by weight (pV/W) performance of 210 J/g (834 000 in-lb/lbm) at burst; this represented a 25 to 30% weight saving over the lightest weight comparable, 6A1-4V Ti, homogeneous pressure vessel. Both the Kevlar/stainless steel design and the 97 cm (38 inch) diameter Kevlar-49/2219-T62 aluminum sphere design demonstrated nonfragmentation and controlled failure mode features when pressure cycled to failure at operating pressure. When failure occurred during pressure cycling, the mode was localized leakage and not catastrophic. Kevlar/stainless steel vessels utilized a unique conical boss design, and Kevlar/aluminum vessels incorporated a tie-rod to carry port loads; both styles of polar fittings performed as designed during operational testing of the vessels.

  9. OAO-3 end of mission power subsystem evaluation

    NASA Technical Reports Server (NTRS)

    Tasevoli, M.

    1982-01-01

    End of mission tests were performed on the OAO-3 power subsystem in three component areas: solar array, nickel-cadmium batteries and the On-Board Processor (OBP) power boost operation. Solar array evaluation consisted of analyzing array performance characteristics and comparing them to earlier flight data. Measured solar array degradation of 14.1 to 17.7% after 8 1/3 years is in good agreement with theortical radiation damage losses. Battery discharge characteristics were compared to results of laboratory life cycle tests performed on similar cells. Comparison of cell voltage profils reveals close correlation and confirms the validity of real time life cycle simulation. The successful operation of the system in the OBP/power boost regulation mode demonstrates the excellent life, reliability and greater system utilization of power subsystems using maximum power trackers.

  10. Relative health performance in BRICS over the past 20 years: the winners and losers.

    PubMed

    Petrie, Dennis; Tang, Kam Ki

    2014-06-01

    To determine whether the health performance of Brazil, the Russian Federation, India, China and South Africa--the countries known as BRICS--has kept in step with their economic development. Reductions in age- and sex-specific mortality seen in each BRICS country between 1990 and 2011 were measured. These results were compared with those of the best-performing countries in the world and the best-performing countries with similar income levels. We estimated each country's progress in reducing mortality and compared changes in that country's mortality rates against other countries with similar mean incomes to examine changes in avoidable mortality. The relative health performance of the five study countries differed markedly over the study period. Brazil demonstrated fairly even improvement in relative health performance across the different age and sex subgroups that we assessed. India's improvement was more modest and more varied across the subgroups. South Africa and the Russian Federation exhibited large declines in health performance as well as large sex-specific inequalities in health. Although China's levels of avoidable mortality decreased in absolute terms, the level of improvement appeared low in the context of China's economic growth. When evaluating a country's health performance in terms of avoidable mortality, it is useful to compare that performance against the performance of other countries. Such comparison allows any country-specific improvements to be distinguished from general global improvements.

  11. Performance of an automated solid-phase red cell adherence system compared with that of a manual gel microcolumn assay for the identification of antibodies eluted from red blood cells.

    PubMed

    Finck, R H; Davis, R J; Teng, S; Goldfinger, D; Ziman, A F; Lu, Q; Yuan, S

    2011-01-01

    IgG antibodies coating red blood cells (RBCs) can be removed by elution procedures and their specificity determined by antibody identification studies. Although such testing is traditionally performed using the tube agglutination assay, prior studies have shown that the gel microcolumn (GMC) assay may also be used with comparable results. The purpose of this study was to compare an automated solid-phase red cell adherence (SPRCA) system with a GMC assay for the detection of antibodies eluted from RBCs. Acid eluates from 51 peripheral blood (PB) and 7 cord blood (CB) samples were evaluated by both an automated SPRCA instrument and a manual GMC assay. The concordance rate between the two systems for peripheral RBC samples was 88.2 percent (45 of 51), including cases with alloantibodies (n = 8), warm autoantibodies (n = 12), antibodies with no identifiable specificity (n = 2), and negative results (n = 23). There were six discordant cases, of which four had alloantibodies (including anti-Jka, -E, and -e) demonstrable by the SPRCA system only. In the remaining 2 cases, anti-Fya and antibodies with no identifiable specificity were demonstrable by the GMC assay only. All seven CB specimens produced concordant results, showing anti-A (n = 3), -B (n = 1), maternal anti-Jka (n = 2), or a negative result (n = 1). Automated SPRCA technology has a performance that is comparable with that of a manual GMC assay for identifying antibodies eluted from PB and CB RBCs.

  12. Electromyography findings of the cricopharyngeus in association with ipsilateral pharyngeal and laryngeal muscles.

    PubMed

    Halum, Stacey L; Shemirani, Nima L; Merati, Albert L; Jaradeh, Safwan; Toohill, Robert J

    2006-04-01

    We reviewed a large series of cricopharyngeal (CP) muscle electromyography (EMG) results and compared them with the EMG results from the inferior constrictor (IC), thyroarytenoid, (TA), cricothyroid (CT), and posterior cricoarytenoid (PCA) muscles. We performed a retrospective review of all CP muscle EMG reports from studies performed between January 1996 and June 2003. All of the tested elements from the CP muscle EMG reports were recorded. The EMG results were recorded for the ipsilateral IC, TA, CT, and PCA muscles if they were simultaneously tested. Each muscle result was classified as normal, neurogenic inactive axonal injury (IAI), or neurogenic active axonal injury (AAI), and the muscle findings were compared. A patient chart review was performed to determine a clinical correlation. Fifty-nine patients underwent CP muscle EMG. Eighteen patients had bilateral EMG studies, making a total of 77 CP muscle studies. Nineteen sets of CP muscle results were normal, 43 demonstrated neurogenic IAI, and 15 demonstrated neurogenic AAI. The ipsilateral IC and CP muscles had the same innervation status in 27 of 28 studies (p < .0001). When the ipsilateral TA muscle was studied simultaneously with the CP muscle, 31 of 50 studies had the same innervation status (p = .005). The ipsilateral CT and CP muscles demonstrated the same innervation status in 40 of 50 studies (p < .0001). The correlations between the CP and IC muscle findings and between the CP and CT muscle findings were both stronger than the correlation between the CP and TA muscle findings (p < .0001 and p = .024, respectively). The chart review demonstrated the clinical findings to be consistent with the EMG results. The EMG studies demonstrated that CP muscle findings have the strongest correlation with IC muscle findings, followed by the CT and TA muscles. This outcome does not support theories indicating that the recurrent laryngeal nerve innervates the CP muscle in all cases.

  13. Differences in kinematics of single leg squatting between anterior cruciate ligament-injured patients and healthy controls.

    PubMed

    Yamazaki, J; Muneta, T; Ju, Y J; Sekiya, I

    2010-01-01

    Seventy to eighty percent of all anterior cruciate ligament (ACL) injuries are due to non-contact injury mechanisms. It has been reported that the majority of injuries due to single leg landing come from valgus positioning of the lower leg. Preventing valgus positioning during single leg landing is expected to help reduce the number of ACL injuries. We found that many ACL-deficient patients cannot perform stable single leg squatting. Therefore, we performed 3D motion analysis of the single-legged half squat for ACL-injured patients to evaluate its significance as a risk factor for ACL injuries. We evaluated the relative angles between the body, thigh, and lower leg using an electromagnetic device during single leg half squatting performed by 63 ACL-injured patients (32 males, 31 females) the day before ACL reconstruction and by 26 healthy control subjects with no knee problems. The uninjured leg of ACL-injured male subjects demonstrated significantly less external knee rotation than that of the dominant leg of the male control. The uninjured leg of ACL-injured female subjects demonstrated significantly more external hip rotation and knee flexion and less hip flexion than that of the dominant leg of the female control. Comparing injured and uninjured legs, the injured leg of male subjects demonstrated significantly less external knee and hip rotation, less knee flexion, and more knee varus than that of the uninjured leg of male subjects. The injured leg of female subjects demonstrated more knee varus than that of the uninjured leg of female subjects. Regarding gender differences, female subjects demonstrated significantly more external hip rotation and knee valgus than male subjects did in both the injured and uninjured legs (P < 0.05). The current kinematic study exhibited biomechanical characteristics of female ACL-injured subjects compared with that of control groups. Kinematic correction during single leg half squat would reduce ACL reinjury in female ACL-injured subjects.

  14. Virtual lab demonstrations improve students' mastery of basic biology laboratory techniques.

    PubMed

    Maldarelli, Grace A; Hartmann, Erica M; Cummings, Patrick J; Horner, Robert D; Obom, Kristina M; Shingles, Richard; Pearlman, Rebecca S

    2009-01-01

    Biology laboratory classes are designed to teach concepts and techniques through experiential learning. Students who have never performed a technique must be guided through the process, which is often difficult to standardize across multiple lab sections. Visual demonstration of laboratory procedures is a key element in teaching pedagogy. The main goals of the study were to create videos explaining and demonstrating a variety of lab techniques that would serve as teaching tools for undergraduate and graduate lab courses and to assess the impact of these videos on student learning. Demonstrations of individual laboratory procedures were videotaped and then edited with iMovie. Narration for the videos was edited with Audacity. Undergraduate students were surveyed anonymously prior to and following screening to assess the impact of the videos on student lab performance by completion of two Participant Perception Indicator surveys. A total of 203 and 171 students completed the pre- and posttesting surveys, respectively. Statistical analyses were performed to compare student perceptions of knowledge of, confidence in, and experience with the lab techniques before and after viewing the videos. Eleven demonstrations were recorded. Chi-square analysis revealed a significant increase in the number of students reporting increased knowledge of, confidence in, and experience with the lab techniques after viewing the videos. Incorporation of instructional videos as prelaboratory exercises has the potential to standardize techniques and to promote successful experimental outcomes.

  15. Comparison of brain connectivity between Internet gambling disorder and Internet gaming disorder: A preliminary study.

    PubMed

    Bae, Sujin; Han, Doug Hyun; Jung, Jaebum; Nam, Ki Chun; Renshaw, Perry F

    2017-12-01

    Background and aims Given the similarities in clinical symptoms, Internet gaming disorder (IGD) is thought to be diagnostically similar to Internet-based gambling disorder (ibGD). However, cognitive enhancement and educational use of Internet gaming suggest that the two disorders derive from different neurobiological mechanisms. The goal of this study was to compare subjects with ibGD to those with IGD. Methods Fifteen patients with IGD, 14 patients with ibGD, and 15 healthy control subjects were included in this study. Resting-state functional magnetic resonance imaging data for all participants were acquired using a 3.0 Tesla MRI scanner (Philips, Eindhoven, The Netherlands). Seed-based analyses, the three brain networks of default mode, cognitive control, and reward circuitry, were performed. Results Both IGD and ibGD groups demonstrated decreased functional connectivity (FC) within the default-mode network (DMN) (family-wise error p < .001) compared with healthy control subjects. However, the IGD group demonstrated increased FC within the cognitive network compared with both the ibGD (p < .01) and healthy control groups (p < .01). In contrast, the ibGD group demonstrated increased FC within the reward circuitry compared with both IGD (p < .01) and healthy control subjects (p < .01). Discussion and conclusions The IGD and ibGD groups shared the characteristic of decreased FC in the DMN. However, the IGD group demonstrated increased FC within the cognitive network compared with both ibGD and healthy comparison groups.

  16. Efficacy of terbinafine compared to lanoconazole and luliconazole in the topical treatment of dermatophytosis in a guinea pig model.

    PubMed

    Ghannoum, M A; Long, L; Kim, H G; Cirino, A J; Miller, A R; Mallefet, P

    2010-05-01

    The in vivo efficacy of terbinafine was compared to lanoconazole and luliconazole in the topical treatment of dermatophytosis caused by Trichophyton mentagrophytes using a guinea pig model. Topical antifungal treatment commenced three days post-infection, and each agent was applied once daily for seven consecutive days. Upon completion of the treatment period, evaluations of clinical and mycological efficacies were performed, as was scanning electron microscopy (SEM) analyses. Data showed that while all tested antifungals demonstrated significant mycological efficacy in terms of eradicating the fungi over untreated control, terbinafine and luliconazole showed superior clinical efficacy compared to lanoconazole (P-values < 0.001 & 0.003, respectively). Terbinafine demonstrated the highest clinical percent efficacy. SEM analysis revealed hairs from terbinafine and lanoconazole-treated animals had near complete clearance of fungi, while samples from luliconazole-treated animals were covered with debris and few conidia. This study demonstrates that, in general, terbinafine possessed similar efficacy to lanoconazole and luliconazole in the treatment of dermatophytosis. Terbinafine tended to have superior clinical efficacy compared to the azoles tested, although this difference was not statistically significant against luliconazole. This apparent superiority may be due to the fungicidal activity of terbinafine compared to the fungistatic effect of the other two drugs.

  17. Performance evaluation of the time delay digital tanlock loop architectures

    NASA Astrophysics Data System (ADS)

    Al-Kharji Al-Ali, Omar; Anani, Nader; Al-Qutayri, Mahmoud; Al-Araji, Saleh; Ponnapalli, Prasad

    2016-01-01

    This article presents the architectures, theoretical analyses and testing results of modified time delay digital tanlock loop (TDTLs) system. The modifications to the original TDTL architecture were introduced to overcome some of the limitations of the original TDTL and to enhance the overall performance of the particular systems. The limitations addressed in this article include the non-linearity of the phase detector, the restricted width of the locking range and the overall system acquisition speed. Each of the modified architectures was tested by subjecting the system to sudden positive and negative frequency steps and comparing its response with that of the original TDTL. In addition, the performance of all the architectures was evaluated under noise-free as well as noisy environments. The extensive simulation results using MATLAB/SIMULINK demonstrate that the new architectures overcome the limitations they addressed and the overall results confirmed significant improvements in performance compared to the conventional TDTL system.

  18. A preliminary examination of neurocognitive performance and symptoms following a bout of soccer heading in athletes wearing protective soccer headbands.

    PubMed

    Elbin, R J; Beatty, Amanda; Covassin, Tracey; Schatz, Philip; Hydeman, Ana; Kontos, Anthony P

    2015-01-01

    This study compared changes in neurocognitive performance and symptom reports following an acute bout of soccer heading among athletes with and without protective soccer headgear. A total of 25 participants headed a soccer ball 15 times over a 15-minute period, using a proper linear heading technique. Participants in the experimental group completed the heading exercise while wearing a protective soccer headband and controls performed the heading exercise without wearing the soccer headband. Neurocognitive performance and symptom reports were assessed before and after the acute bout of heading. Participants wearing the headband showed significant decreases on verbal memory (p = 0.02) compared with the no headband group, while the no headband group demonstrated significantly faster reaction time (p = 0.03) than the headband group following the heading exercise. These findings suggest that protective soccer headgear likely does not mitigate the subtle neurocognitive effects of acute soccer heading.

  19. A high performance scientific cloud computing environment for materials simulations

    NASA Astrophysics Data System (ADS)

    Jorissen, K.; Vila, F. D.; Rehr, J. J.

    2012-09-01

    We describe the development of a scientific cloud computing (SCC) platform that offers high performance computation capability. The platform consists of a scientific virtual machine prototype containing a UNIX operating system and several materials science codes, together with essential interface tools (an SCC toolset) that offers functionality comparable to local compute clusters. In particular, our SCC toolset provides automatic creation of virtual clusters for parallel computing, including tools for execution and monitoring performance, as well as efficient I/O utilities that enable seamless connections to and from the cloud. Our SCC platform is optimized for the Amazon Elastic Compute Cloud (EC2). We present benchmarks for prototypical scientific applications and demonstrate performance comparable to local compute clusters. To facilitate code execution and provide user-friendly access, we have also integrated cloud computing capability in a JAVA-based GUI. Our SCC platform may be an alternative to traditional HPC resources for materials science or quantum chemistry applications.

  20. Thermal Performance Comparison of Glass Microsphere and Perlite Insulation Systems for Liquid Hydrogen Storage Tanks

    NASA Astrophysics Data System (ADS)

    Sass, J. P.; Fesmire, J. E.; Nagy, Z. F.; Sojourner, S. J.; Morris, D. L.; Augustynowicz, S. D.

    2008-03-01

    A technology demonstration test project was conducted by the Cryogenics Test Laboratory at the Kennedy Space Center (KSC) to provide comparative thermal performance data for glass microspheres, referred to as bubbles, and perlite insulation for liquid hydrogen tank applications. Two identical 1/15th scale versions of the 3,200,000 liter spherical liquid hydrogen tanks at Launch Complex 39 at KSC were custom designed and built to serve as test articles for this test project. Evaporative (boil-off) calorimeter test protocols, including liquid nitrogen and liquid hydrogen, were established to provide tank test conditions characteristic of the large storage tanks that support the Space Shuttle launch operations. This paper provides comparative thermal performance test results for bubbles and perlite for a wide range of conditions. Thermal performance as a function of cryogenic commodity (nitrogen and hydrogen), vacuum pressure, insulation fill level, tank liquid level, and thermal cycles will be presented.

  1. Publicly reported quality-of-care measures influenced Wisconsin physician groups to improve performance

    PubMed Central

    Lamb, Geoffrey C.; Smith, Maureen; Weeks, William B.; Queram, Christopher

    2014-01-01

    Public reporting of performance on quality measures is increasingly common but little is known about the impact, especially among physician groups. The Wisconsin Collaborative for Healthcare Quality (Collaborative) is a voluntary consortium of physician groups which has publicly reported quality measures since 2004, providing an opportunity to study the effect of this effort on participating groups. Analyses included member performance on 14 ambulatory measures from 2004–2009, a survey regarding reporting and its relationship to improvement efforts, and use of Medicare billing data to independently compare Collaborative members to the rest of Wisconsin, neighboring states and the rest of the United States. Faced with limited resources, groups prioritized their efforts based on the nature of the measure and their performance compared to others. The outcomes demonstrated that public reporting was associated with improvement in health quality and that large physician group practices will engage in improvement efforts in response. PMID:23459733

  2. The enhancement of visuospatial processing efficiency through Buddhist Deity meditation.

    PubMed

    Kozhevnikov, Maria; Louchakova, Olga; Josipovic, Zoran; Motes, Michael A

    2009-05-01

    This study examined the effects of meditation on mental imagery, evaluating Buddhist monks' reports concerning their extraordinary imagery skills. Practitioners of Buddhist meditation were divided into two groups according to their preferred meditation style: Deity Yoga (focused attention on an internal visual image) or Open Presence (evenly distributed attention, not directed to any particular object). Both groups of meditators completed computerized mental-imagery tasks before and after meditation. Their performance was compared with that of control groups, who either rested or performed other visuospatial tasks between testing sessions. The results indicate that all the groups performed at the same baseline level, but after meditation, Deity Yoga practitioners demonstrated a dramatic increase in performance on imagery tasks compared with the other groups. The results suggest that Deity meditation specifically trains one's capacity to access heightened visuospatial processing resources, rather than generally improving visuospatial imagery abilities.

  3. COMPARATIVE EFFECTIVENESS OF AN ADJUSTABLE TRANSFEMORAL PROSTHETIC INTERFACE ACCOMMODATING VOLUME FLUCTUATION: CASE STUDY

    PubMed Central

    Kahle, Jason T.; Klenow, Tyler D.; Highsmith, M. Jason

    2016-01-01

    The socket-limb interface is vital for functionality and provides stability and mobility for the amputee. Volume fluctuation can lead to compromised fit and function. Current socket technology does not accommodate for volume fluctuation. An adjustable interface may improve function and comfort by filling this technology gap. The purpose of this study was to compare the effectiveness of the standard of care (SOC) ischial ramus containment to an adjustable transfemoral prosthetic interface socket in the accommodation of volume fluctuation. A prospective experimental case study using repeated measures of subjective and performance outcome measures between socket conditions was employed. In the baseline volume condition, the adjustable socket improved subjective and performance measures 19% to 37% over SOC, whereas the two-minute walk test demonstrated equivalence. In the volume loss condition, the adjustable socket improved all subjective and performance measures 22% to 93%. All aggregated data improved 16% to 50% compared with the SOC. In simulated volume gain, the SOC socket failed, while the subject was able to complete the protocol using the adjustable socket. In this case study, the SOC socket was inferior to the comparative adjustable transfemoral amputation interface in subjective and performance outcomes. There is a lack of clinical trials and evidence comparing socket functional outcomes related to volume fluctuation. PMID:28066526

  4. Performance Outcomes After Hook of Hamate Fractures in Major League Baseball Players.

    PubMed

    Guss, Michael S; Begly, John P; Ramme, Austin J; Taormina, David P; Rettig, Michael E; Capo, John T

    2017-07-17

    Major League Baseball (MLB) players are at risk of hook of hamate fractures. There is a paucity of data assessing the effect of a hook of hamate fracture on MLB players' future athletic performance. To determine if MLB players who sustain hook of hamate fractures demonstrate decreased performance upon return to competition when compared with their performance before injury and that of their control-matched peers. Retrospective Case-Control Design. Retrospective Database Study. 18 MLB players who sustained hook of hamate fractures. Data for 18 MLB players with hook of hamate fractures incurred over 26 seasons (1989 to 2014) were obtained from injury reports, press releases, and player profiles ( www.mlb.com and www.baseballreference.com ). Player age, position, number of years in the league, mechanism of injury and treatment were recorded. Individual season statistics for the two seasons immediately prior to injury and the two seasons after injury for the main performance variable - wins above replacement (WAR) were obtained. Eighteen controls matched by player position, age, and performance statistics were identified. A performance comparison of the cohorts was performed. Post-injury performance compared to pre-injury performance and matched-controls. Mean age at the time of injury was 25.1 years with a mean of 4.4 seasons of MLB experience prior to injury. All injuries were sustained to their nondominant batting hand. All players underwent operative intervention. There was no significant change in WAR or ISO when pre-injury and post-injury performance was compared. When compared with matched-controls, no significant decline in performance in WAR the first season and second season after injury was found. MLB players sustaining hook of hamate fractures can reasonably expect to return to their pre-injury performance levels following operative treatment.

  5. Do repeated assessments of performance status improve predictions for risk of death among patients with cancer? A population-based cohort study.

    PubMed

    Su, Jiandong; Barbera, Lisa; Sutradhar, Rinku

    2015-06-01

    Prior work has utilized longitudinal information on performance status to demonstrate its association with risk of death among cancer patients; however, no study has assessed whether such longitudinal information improves the predictions for risk of death. To examine whether the use of repeated performance status assessments improve predictions for risk of death compared to using only performance status assessment at the time of cancer diagnosis. This was a population-based longitudinal study of adult outpatients who had a cancer diagnosis and had at least one assessment of performance status. To account for each patient's changing performance status over time, we implemented a Cox model with a time-varying covariate for performance status. This model was compared to a Cox model using only a time-fixed (baseline) covariate for performance status. The regression coefficients of each model were derived based on a randomly selected 60% of patients, and then, the predictive ability of each model was assessed via concordance probabilities when applied to the remaining 40% of patients. Our study consisted of 15,487 cancer patients with over 53,000 performance status assessments. The utilization of repeated performance status assessments improved predictions for risk of death compared to using only the performance status assessment taken at diagnosis. When studying the hazard of death among patients with cancer, if available, researchers should incorporate changing information on performance status scores, instead of simply baseline information on performance status. © The Author(s) 2015.

  6. Demonstration of Robustness and Integrated Operation of a Series-Bosch System

    NASA Technical Reports Server (NTRS)

    Abney, Morgan B.; Mansell, Matthew J.; Stanley, Christine; Barnett, Bill; Junaedi, Christian; Vilekar, Saurabh A.; Ryan, Kent

    2016-01-01

    Manned missions beyond low Earth orbit will require highly robust, reliable, and maintainable life support systems that maximize recycling of water and oxygen. Bosch technology is one option to maximize oxygen recovery, in the form of water, from metabolically-produced carbon dioxide (CO2). A two stage approach to Bosch, called Series-Bosch, reduces metabolic CO2 with hydrogen (H2) to produce water and solid carbon using two reactors: a Reverse Water-Gas Shift (RWGS) reactor and a carbon formation (CF) reactor. Previous development efforts demonstrated the stand-alone performance of a NASA-designed RWGS reactor designed for robustness against carbon formation, two membrane separators intended to maximize single pass conversion of reactants, and a batch CF reactor with both transit and surface catalysts. In the past year, Precision Combustion, Inc. (PCI) developed and delivered a RWGS reactor for testing at NASA. The reactor design was based on their patented Microlith® technology and was first evaluated under a Phase I Small Business Innovative Research (SBIR) effort in 2010. The RWGS reactor was recently evaluated at NASA to compare its performance and operating conditions with NASA's RWGS reactor. The test results will be provided in this paper. Separately, in 2015, a semi-continuous CF reactor was designed and fabricated at NASA based on the results from batch CF reactor testing. The batch CF reactor and the semi-continuous CF reactor were individually integrated with an upstream RWGS reactor to demonstrate the system operation and to evaluate performance. Here, we compare the performance and robustness to carbon formation of both RWGS reactors. We report the results of the integrated operation of a Series-Bosch system and we discuss the technology readiness level.

  7. Musical training, bilingualism, and executive function: a closer look at task switching and dual-task performance.

    PubMed

    Moradzadeh, Linda; Blumenthal, Galit; Wiseheart, Melody

    2015-07-01

    This study investigated whether musical training and bilingualism are associated with enhancements in specific components of executive function, namely, task switching and dual-task performance. Participants (n = 153) belonging to one of four groups (monolingual musician, bilingual musician, bilingual non-musician, or monolingual non-musician) were matched on age and socioeconomic status and administered task switching and dual-task paradigms. Results demonstrated reduced global and local switch costs in musicians compared with non-musicians, suggesting that musical training can contribute to increased efficiency in the ability to shift flexibly between mental sets. On dual-task performance, musicians also outperformed non-musicians. There was neither a cognitive advantage for bilinguals relative to monolinguals, nor an interaction between music and language to suggest additive effects of both types of experience. These findings demonstrate that long-term musical training is associated with improvements in task switching and dual-task performance. Copyright © 2014 Cognitive Science Society, Inc.

  8. High-speed engine/component performance assessment using exergy and thrust-based methods

    NASA Technical Reports Server (NTRS)

    Riggins, D. W.

    1996-01-01

    This investigation summarizes a comparative study of two high-speed engine performance assessment techniques based on energy (available work) and thrust-potential (thrust availability). Simple flow-fields utilizing Rayleigh heat addition and one-dimensional flow with friction are used to demonstrate the fundamental inability of conventional energy techniques to predict engine component performance, aid in component design, or accurately assess flow losses. The use of the thrust-based method on these same examples demonstrates its ability to yield useful information in all these categories. Energy and thrust are related and discussed from the stand-point of their fundamental thermodynamic and fluid dynamic definitions in order to explain the differences in information obtained using the two methods. The conventional definition of energy is shown to include work which is inherently unavailable to an aerospace Brayton engine. An engine-based energy is then developed which accurately accounts for this inherently unavailable work; performance parameters based on this quantity are then shown to yield design and loss information equivalent to the thrust-based method.

  9. Patterns of prospective memory impairment among individuals with depression: the influence of cue type and delay interval.

    PubMed

    Li, Yanqi Ryan; Weinborn, Michael; Loft, Shayne; Maybery, Murray

    2013-07-01

    The present study investigated the impact of cue type and delay interval on prospective memory performance in depressed, compared to non-depressed, individuals using a clinically relevant measure, the Memory for Intentions Screening Test. The depressed group demonstrated impaired performance on time-based, but not event-based, prospective memory tasks relative to the nondepressed group. The depressed group also demonstrated impaired prospective memory on tasks with longer delay intervals (15 min), but not on tasks with shorter delay intervals (2 min). These data support theoretical frameworks that posit that depression is associated with deficits in cognitive initiative (i.e., reduced ability to voluntarily direct attention to relevant tasks) and thus that depressed individuals are susceptible to poor performance on strategically demanding tasks. The results also raise multiple avenues for developing interventions (e.g., implementation intentions) to improve prospective memory performance among individuals with depression, with potential implications for medication and other treatment adherence.

  10. Comfort-oriented vehicle suspension design with skyhook inerter configuration

    NASA Astrophysics Data System (ADS)

    Hu, Yinlong; Chen, Michael Z. Q.; Sun, Yonghui

    2017-09-01

    This paper is concerned with the comfort-oriented vehicle suspension design problem by using a skyhook inerter configuration. The rationale of the skyhook inerter is to use a grounded inerter to virtually increase the sprung mass of a vehicle, as it is analytically demonstrated that increasing the sprung mass can always improve the ride comfort performance. Semi-active means to realize the skyhook inerter configuration are investigated by using semi-active inerters. Three control laws, that is the on-off control, the anti-chatter on-off control, and the continuous control, are proposed for the semi-active inerter to approximate the skyhook inerter. Numerical simulations are performed to demonstrate the effectiveness and performances of these control laws. It is shown that the semi-active realizations of the skyhook inerter by using the proposed control laws can achieve over 10% improvement compared with the traditional strut, and similar performances are obtained for these control laws, with slight differences with respect to different static stiffnesses of the suspension system.

  11. Has there been a change in the knowledge of GP registrars between 2011 and 2016 as measured by performance on common items in the Applied Knowledge Test?

    PubMed

    Neden, Catherine A; Parkin, Claire; Blow, Carol; Siriwardena, Aloysius Niroshan

    2018-05-08

    The aim of this study was to assess whether the absolute standard of candidates sitting the MRCGP Applied Knowledge Test (AKT) between 2011 and 2016 had changed. It is a descriptive study comparing the performance on marker questions of a reference group of UK graduates taking the AKT for the first time between 2011 and 2016. Using aggregated examination data, the performance of individual 'marker' questions was compared using Pearson's chi-squared tests and trend-line analysis. Binary logistic regression was used to analyse changes in performance over the study period. Changes in performance of individual marker questions using Pearson's chi-squared test showed statistically significant differences in 32 of the 49 questions included in the study. Trend line analysis showed a positive trend in 29 questions and a negative trend in the remaining 23. The magnitude of change was small. Logistic regression did not demonstrate any evidence for a change in the performance of the question set over the study period. However, candidates were more likely to get items on administration wrong compared with clinical medicine or research. There was no evidence of a change in performance of the question set as a whole.

  12. Comparative evaluation of performance measures for shading correction in time-lapse fluorescence microscopy.

    PubMed

    Liu, L; Kan, A; Leckie, C; Hodgkin, P D

    2017-04-01

    Time-lapse fluorescence microscopy is a valuable technology in cell biology, but it suffers from the inherent problem of intensity inhomogeneity due to uneven illumination or camera nonlinearity, known as shading artefacts. This will lead to inaccurate estimates of single-cell features such as average and total intensity. Numerous shading correction methods have been proposed to remove this effect. In order to compare the performance of different methods, many quantitative performance measures have been developed. However, there is little discussion about which performance measure should be generally applied for evaluation on real data, where the ground truth is absent. In this paper, the state-of-the-art shading correction methods and performance evaluation methods are reviewed. We implement 10 popular shading correction methods on two artificial datasets and four real ones. In order to make an objective comparison between those methods, we employ a number of quantitative performance measures. Extensive validation demonstrates that the coefficient of joint variation (CJV) is the most applicable measure in time-lapse fluorescence images. Based on this measure, we have proposed a novel shading correction method that performs better compared to well-established methods for a range of real data tested. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  13. High-rate lithium thionyl chloride cells

    NASA Technical Reports Server (NTRS)

    Goebel, F.

    1982-01-01

    A high-rate C cell with disc electrodes was developed to demonstrate current rates which are comparable to other primary systems. The tests performed established the limits of abuse beyond which the cell becomes hazardous. Tests include: impact, shock, and vibration tests; temperature cycling; and salt water immersion of fresh cells.

  14. Evaluating the Outcomes of Advanced Neonatal Nurse Practitioner Programmes.

    ERIC Educational Resources Information Center

    Redshaw, Margaret; Hart, Bev; Harvey, Merryl; Harris, Anne

    The outcomes of advanced neonatal nurse practitioner (ANNP) programs in the United Kingdom were examined. The different programs of education currently available for nurses wishing to become ANNPs were compared, and the outcomes of ANNP programs, as demonstrated in the levels of performance of practitioners undertaking different programs, were…

  15. Transit Car Performance Comparison, State-of-the-Art Car vs. PATCO Transit Car, NYCTA R-46, MBTA Silverbirds

    DOT National Transportation Integrated Search

    1978-02-01

    The first phase of this contract authorized the design, development, and demonstration of two State-Of-The-Art Cars (SOAC). This document reports on the gathering of comparative test data on existing in-service transit cars. The three transit cars se...

  16. Knowledge Transfer in Online Learning Environments

    ERIC Educational Resources Information Center

    Hansen, David E.

    2008-01-01

    Research comparing online and traditional course delivery methods has sought to demonstrate the equivalence of student performance in online and traditional courses. This study examines the unique proposition that online course delivery is superior to traditional when it comes to applied learning and is thus superior in the process of knowledge…

  17. Learning Geometry Problem Solving by Studying Worked Examples: Effects of Learner Guidance and Expertise

    ERIC Educational Resources Information Center

    Bokosmaty, Sahar; Sweller, John; Kalyuga, Slava

    2015-01-01

    Research has demonstrated that instruction that relies heavily on studying worked examples is more effective for less experienced learners compared to instruction emphasizing problem solving. However, the guidance associated with studying some worked examples may reduce the performance of more experienced learners. This study investigated…

  18. Psychological Adjustment and Neuropsychological Performance in Diabetic Patients.

    ERIC Educational Resources Information Center

    Skenazy, Judy A.; Bigler, Erin D.

    1985-01-01

    Compared diabetic (N=39) with nondiabetic chronic illness patients (N=20) and healthy controls (N=24). The chronic illness and the diabetic groups had significant elevations on the Hypochondriasis, Depression, and Hysteria scales of the Feschingbauer Abbreviated MMPI. For diabetics, results demonstrated a negligible effect of poor adjustment on…

  19. Investigations on the performance of chevron type plate heat exchangers

    NASA Astrophysics Data System (ADS)

    Dutta, Oruganti Yaga; Nageswara Rao, B.

    2018-01-01

    This paper presents empirical relations for the chevron type plate heat exchangers (PHEs) and demonstrated their validity through comparison of test data of PHEs. In order to examine the performance of PHEs, the pressure drop(Δ P), the overall heat transfer coefficient ( U m ) and the effectiveness ( ɛ) are estimated by considering the properties of plate material and working fluid, number of plates ( N t ) and chevron angle( β). It is a known fact that, large surface area of the plate provides more rate of heat transfer ( \\dot{Q} ) thereby more effectiveness ( ɛ). However, there is a possibility to achieve the required performance by increasing the number of plates without altering the plate dimensions, which avoids the new design of the system. Application of the Taguchi's design of experiments is examined with less number of experiments and demonstrated by setting the levels for the parameters and compared the test data with the estimated output responses.

  20. Electrostatic actuation and electromechanical switching behavior of one-dimensional nanostructures.

    PubMed

    Subramanian, Arunkumar; Alt, Andreas R; Dong, Lixin; Kratochvil, Bradley E; Bolognesi, Colombo R; Nelson, Bradley J

    2009-10-27

    We report on the electromechanical actuation and switching performance of nanoconstructs involving doubly clamped, individual multiwalled carbon nanotubes. Batch-fabricated, three-state switches with low ON-state voltages (6.7 V average) are demonstrated. A nanoassembly architecture that permits individual probing of one device at a time without crosstalk from other nanotubes, which are originally assembled in parallel, is presented. Experimental investigations into device performance metrics such as hysteresis, repeatability and failure modes are presented. Furthermore, current-driven shell etching is demonstrated as a tool to tune the nanomechanical clamping configuration, stiffness, and actuation voltage of fabricated devices. Computational models, which take into account the nonlinearities induced by stress-stiffening of 1-D nanowires at large deformations, are presented. Apart from providing accurate estimates of device performance, these models provide new insights into the extension of stable travel range in electrostatically actuated nanowire-based constructs as compared to their microscale counterparts.

  1. Enhanced thermoelectric performance of graphene nanoribbon-based devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hossain, Md Sharafat, E-mail: hossain@student.unimelb.edu.au; Huynh, Duc Hau; Nguyen, Phuong Duc

    There have been numerous theoretical studies on exciting thermoelectric properties of graphene nano-ribbons (GNRs); however, most of these studies are mainly based on simulations. In this work, we measure and characterize the thermoelectric properties of GNRs and compare the results with theoretical predictions. Our experimental results verify that nano-structuring and patterning graphene into nano-ribbons significantly enhance its thermoelectric power, confirming previous predictions. Although patterning results in lower conductance (G), the overall power factor (S{sup 2}G) increases for nanoribbons. We demonstrate that edge roughness plays an important role in achieving such an enhanced performance and support it through first principles simulations.more » We show that uncontrolled edge roughness, which is considered detrimental in GNR-based electronic devices, leads to enhanced thermoelectric performance of GNR-based thermoelectric devices. The result validates previously reported theoretical studies of GNRs and demonstrates the potential of GNRs for the realization of highly efficient thermoelectric devices.« less

  2. Transport composite fuselage technology: Impact dynamics and acoustic transmission

    NASA Technical Reports Server (NTRS)

    Jackson, A. C.; Balena, F. J.; Labarge, W. L.; Pei, G.; Pitman, W. A.; Wittlin, G.

    1986-01-01

    A program was performed to develop and demonstrate the impact dynamics and acoustic transmission technology for a composite fuselage which meets the design requirements of a 1990 large transport aircraft without substantial weight and cost penalties. The program developed the analytical methodology for the prediction of acoustic transmission behavior of advanced composite stiffened shell structures. The methodology predicted that the interior noise level in a composite fuselage due to turbulent boundary layer will be less than in a comparable aluminum fuselage. The verification of these analyses will be performed by NASA Langley Research Center using a composite fuselage shell fabricated by filament winding. The program also developed analytical methodology for the prediction of the impact dynamics behavior of lower fuselage structure constructed with composite materials. Development tests were performed to demonstrate that the composite structure designed to the same operating load requirement can have at least the same energy absorption capability as aluminum structure.

  3. Modification of UASB reactor by using CFD simulations for enhanced treatment of municipal sewage.

    PubMed

    Das, Suprotim; Sarkar, Supriya; Chaudhari, Sanjeev

    2018-02-01

    Up-flow anaerobic sludge blanket (UASB) has been in use since last few decades for the treatment of organic wastewaters. However, the performance of UASB reactor is quite low for treatment of low strength wastewaters (LSWs) due to less biogas production leading to poor mixing. In the present research work, a modification was done in the design of UASB to improve mixing of reactor liquid which is important to enhance the reactor performance. The modified UASB (MUASB) reactor was designed by providing a slanted baffle along the height of the reactor having an angle of 5.7° with the vertical wall. A two-dimensional computational fluid dynamics (CFD) simulation of three phase gas-liquid-solid flow in MUASB reactor was performed and compared with conventional UASB reactor. The CFD study indicated better mixing in terms of vorticity magnitude in MUASB reactor as compared to conventional UASB, which was reflected in the reactor performance. The performance of MUASB was compared with conventional UASB reactor for the onsite treatment of domestic sewage as LSW. Around 16% higher total chemical oxygen demand removal efficiency was observed in MUASB reactor as compared to conventional UASB during this study. Therefore, this MUASB model demonstrates a qualitative relationship between mixing and performance during the treatment of LSW. From the study, it seems that MUASB holds promise for field applications.

  4. A Machine Learning-based Method for Question Type Classification in Biomedical Question Answering.

    PubMed

    Sarrouti, Mourad; Ouatik El Alaoui, Said

    2017-05-18

    Biomedical question type classification is one of the important components of an automatic biomedical question answering system. The performance of the latter depends directly on the performance of its biomedical question type classification system, which consists of assigning a category to each question in order to determine the appropriate answer extraction algorithm. This study aims to automatically classify biomedical questions into one of the four categories: (1) yes/no, (2) factoid, (3) list, and (4) summary. In this paper, we propose a biomedical question type classification method based on machine learning approaches to automatically assign a category to a biomedical question. First, we extract features from biomedical questions using the proposed handcrafted lexico-syntactic patterns. Then, we feed these features for machine-learning algorithms. Finally, the class label is predicted using the trained classifiers. Experimental evaluations performed on large standard annotated datasets of biomedical questions, provided by the BioASQ challenge, demonstrated that our method exhibits significant improved performance when compared to four baseline systems. The proposed method achieves a roughly 10-point increase over the best baseline in terms of accuracy. Moreover, the obtained results show that using handcrafted lexico-syntactic patterns as features' provider of support vector machine (SVM) lead to the highest accuracy of 89.40 %. The proposed method can automatically classify BioASQ questions into one of the four categories: yes/no, factoid, list, and summary. Furthermore, the results demonstrated that our method produced the best classification performance compared to four baseline systems.

  5. Design and Performance of the NASA SCEPTOR Distributed Electric Propulsion Flight Demonstrator

    NASA Technical Reports Server (NTRS)

    Borer, Nicholas K.; Patterson, Michael D.; Viken, Jeffrey K.; Moore, Mark D.; Clarke, Sean; Redifer, Matthew E.; Christie, Robert J.; Stoll, Alex M.; Dubois, Arthur; Bevirt, JoeBen; hide

    2016-01-01

    Distributed Electric Propulsion (DEP) technology uses multiple propulsors driven by electric motors distributed about the airframe to yield beneficial aerodynamic-propulsion interaction. The NASA SCEPTOR flight demonstration project will retrofit an existing internal combustion engine-powered light aircraft with two types of DEP: small "high-lift" propellers distributed along the leading edge of the wing which accelerate the flow over the wing at low speeds, and larger cruise propellers co-located with each wingtip for primary propulsive power. The updated high-lift system enables a 2.5x reduction in wing area as compared to the original aircraft, reducing drag at cruise and shifting the velocity for maximum lift-to-drag ratio to a higher speed, while maintaining low-speed performance. The wingtip-mounted cruise propellers interact with the wingtip vortex, enabling a further efficiency increase that can reduce propulsive power by 10%. A tradespace exploration approach is developed that enables rapid identification of salient trades, and subsequent creation of SCEPTOR demonstrator geometries. These candidates were scrutinized by subject matter experts to identify design preferences that were not modeled during configuration exploration. This exploration and design approach is used to create an aircraft that consumes an estimated 4.8x less energy at the selected cruise point when compared to the original aircraft.

  6. Infrared absorption spectroscopy and sensing of protein monolayers using high performance enhancing substrates and a mobile phone (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Dana, Aykutlu; Ayas, Sencer; Bakan, Gokhan; Ozgur, Erol; Guner, Hasan; Celebi, Kemal

    2016-09-01

    Infrared absorption spectroscopy has greatly benefited from the electromagnetic field enhancement offered by plasmonic surfaces. However, because of the localized nature of plasmonic fields, such field enhancements are limited to nm-scale volumes. Here, we demonstrate that a relatively small, but spatially-uniform field enhancement can yield a superior infrared detection performance compared to the plasmonic field enhancement exhibited by optimized infrared nanoantennas. A specifically designed CaF2/Al thin film surface is shown to enable observation of stronger vibrational signals from the probe material, with wider bandwidth and a deeper spatial extent of the field enhancement as compared to optimized plasmonic surfaces. It is demonstrated that the surface structure presented here can enable chemically specific and label-free detection of organic monolayers using surface enhanced infrared spectroscopy. Also, a low cost hand held infrared absorption measurement setup is demonstrated using a miniature bolometric sensor and a mobile phone. A specifically designed grating in combination with an IR light source yields an IR spectrometer covering 7-12 um range, with about 100 cm-1 resolution. Combining the enhancing substrates with the spectroscopy setup, low cost, high sensitivity mobile infrared sensing is enabled. The results have implications in homeland security and environmental monitoring as well as chemical analysis.

  7. Non-linguistic learning in aphasia: Effects of training method and stimulus characteristics

    PubMed Central

    Vallila-Rohter, Sofia; Kiran, Swathi

    2013-01-01

    Purpose The purpose of the current study was to explore non-linguistic learning ability in patients with aphasia, examining the impact of stimulus typicality and feedback on success with learning. Method Eighteen patients with aphasia and eight healthy controls participated in this study. All participants completed four computerized, non-linguistic category-learning tasks. We probed learning ability under two methods of instruction: feedback-based (FB) and paired-associate (PA). We also examined the impact of task complexity on learning ability, comparing two stimulus conditions: typical (Typ) and atypical (Atyp). Performance was compared between groups and across conditions. Results Results demonstrated that healthy controls were able to successfully learn categories under all conditions. For our patients with aphasia, two patterns of performance arose. One subgroup of patients was able to maintain learning across task manipulations and conditions. The other subgroup of patients demonstrated a sensitivity to task complexity, learning successfully only in the typical training conditions. Conclusions Results support the hypothesis that impairments of general learning are present in aphasia. Some patients demonstrated the ability to extract category information under complex training conditions, while others learned only under conditions that were simplified and emphasized salient category features. Overall, the typical training condition facilitated learning for all participants. Findings have implications for therapy, which are discussed. PMID:23695914

  8. Segmentectomy versus lobectomy in early non-small cell lung cancer of 2 cm or less in size: A population-based study.

    PubMed

    Moon, Mi Hyoung; Moon, Young Kyu; Moon, Seok Whan

    2018-02-21

    Standard surgical management for early stage lung cancer is lobectomy with mediastinal lymph node dissection. The feasibility of limited resection remains controversial; we retrospectively assessed lung cancer-specific survival (LCSS) and overall survival (OS) in early stage non-small cell lung cancer (NSCLC) to evaluate whether segmentectomy is comparable to standard lobectomy. Patients with primary NSCLC of 20 mm or less who were diagnosed from 2000 to 2014 were extracted from the Surveillance, Epidemiology, and End Results (SEER) database. To compare the two surgical interventions, a propensity score analysis was performed between lobectomy and segmentectomy. Of the 15 358 patients analysed, there were 14 549 lobectomies and 809 segmentectomies. The 5-year OS was 76% for the lobectomy group and 74.4% for the segmentectomy group. There were no significant differences in OS or LCSS among patients who underwent lobectomy versus segmentectomy, as demonstrated by the propensity-matched hazard ratio (HR) for OS (HR: 1.195, 95% CI: 0.993-1.439) and LCSS (HR: 1.124, 95% CI: 0.860-1.469). The inverse propensity-weighted analysis also supported these results. Segmentectomy was more likely to be performed in elderly patients. In the subset of patients aged ≥75 years, the segmentectomy group demonstrated comparable OS (HR: 1.17, 95% CI: 0.87-1.58, P = 0.31) and LCSS (HR: 0.94, 95% CI: 0.59-1.51, P = 0.81), compared with the lobectomy group. Equivalent OS and LCSS were demonstrated in patients with primary NSCLC of 20 mm or less without lymph node or distant metastasis. © 2018 Asian Pacific Society of Respirology.

  9. Acute Exercise Improves Motor Memory Consolidation in Preadolescent Children

    PubMed Central

    Lundbye-Jensen, Jesper; Skriver, Kasper; Nielsen, Jens B.; Roig, Marc

    2017-01-01

    Objective: The ability to acquire new motor skills is essential both during childhood and later in life. Recent studies have demonstrated that an acute bout of exercise can improve motor memory consolidation in adults. The objective of the present study was to investigate whether acute exercise protocols following motor skill practice in a school setting can also improve long-term retention of motor memory in preadolescent children. Methods: Seventy-seven pre-adolescent children (age 10.5 ± 0.75 (SD)) participated in the study. Prior to the main experiment age, BMI, fitness status and general physical activity level was assessed in all children and they were then randomly allocated to three groups. All children practiced a visuomotor tracking task followed by 20 min of rest (CON), high intensity intermittent floorball (FLB) or running (RUN) with comparable exercise intensity and duration for exercise groups. Delayed retention of motor memory was assessed 1 h, 24 h and 7 days after motor skill acquisition. Results: During skill acquisition, motor performance improved significantly to the immediate retention test with no differences between groups. One hour following skill acquisition, motor performance decreased significantly for RUN. Twenty-four hours following skill acquisition there was a tendency towards improved performance for FLB but no significant effects. Seven days after motor practice however, both FLB and RUN performed better when compared to their immediate retention test indicating significant offline gains. This effect was not observed for CON. In contrast, 7 days after motor practice, retention of motor memory was significantly better for FLB and RUN compared to CON. No differences were observed when comparing FLB and RUN. Conclusions: Acute intense intermittent exercise performed immediately after motor skill acquisition facilitates long-term motor memory in pre-adolescent children, presumably by promoting memory consolidation. The results also demonstrate that the effects can be accomplished in a school setting. The positive effect of both a team game (i.e., FLB) and running indicates that the observed memory improvements are determined to a larger extent by physiological factors rather than the types of movements performed during the exercise protocol. PMID:28473761

  10. Performance tradeoff between lateral and interdigitated doping patterns for high speed carrier-depletion based silicon modulators.

    PubMed

    Yu, Hui; Pantouvaki, Marianna; Van Campenhout, Joris; Korn, Dietmar; Komorowska, Katarzyna; Dumon, Pieter; Li, Yanlu; Verheyen, Peter; Absil, Philippe; Alloatti, Luca; Hillerkuss, David; Leuthold, Juerg; Baets, Roel; Bogaerts, Wim

    2012-06-04

    Carrier-depletion based silicon modulators with lateral and interdigitated PN junctions are compared systematically on the same fabrication platform. The interdigitated diode is shown to outperform the lateral diode in achieving a low VπLπ of 0.62 V∙cm with comparable propagation loss at the expense of a higher depletion capacitance. The low VπLπ of the interdigitated PN junction is employed to demonstrate 10 Gbit/s modulation with 7.5 dB extinction ration from a 500 µm long device whose static insertion loss is 2.8 dB. In addition, up to 40 Gbit/s modulation is demonstrated for a 3 mm long device comprising a lateral diode and a co-designed traveling wave electrode.

  11. Impact of movie-based simulation training, with or without conventional verbal demonstration on observed OSPE scores in medical undergraduates: a double control study.

    PubMed

    Malik, Samina; Zaheer, Reema; Bilal, Muhammad

    2013-01-01

    Movie-based simulation training may be useful in delivering the preclinical observed OSPE curriculum, minimising the need of subjects/patients: however, a double-control trial needs to be performed and optimal timing and duration of training is yet to be defined. Likewise, gender-based response and students' feedback has to be assessed. The objective of this study was to compare the movie-based and traditional verbal demonstration teaching methodologies. Second-year medical undergraduates (n = 90) of Avicenna Medical College were randomised to movie-based simulation training (group B, n = 30), traditional verbal training alone (group C, n=30), and a combination (group A, n = 30). The scores were marked by observers using a standardised key and were compared for performance at 2 observed OSPE stations. Group B and A performed significantly better than group C on station 1 and 2. Gender factor did not seem to influence the score. A total of 99% students reported that combination of the 2 teaching modes is the best option. They believed it offers more clear understanding with interest (61%), long term memory (21%), use of both senses; seeing & hearing (10%) & better focus of attention (3%). Even half an hour of movie-based simulation training with traditional instructor-based training may improve student performance significantly, and the students prefer a combination of the both.

  12. An Overview of an Experimental Demonstration Aerotow Program

    NASA Technical Reports Server (NTRS)

    Murray, James E.; Bowers, Albion H.; Lokos, William A.; Peters, Todd L.; Gera, Joseph

    1998-01-01

    An overview of an experimental demonstration of aerotowing a delta-wing airplane with low-aspect ratio and relatively high wing loading is presented. Aerotowing of future space launch configurations is a new concept, and the objective of the work described herein is to demonstrate the aerotow operation using an airplane configuration similar to conceptual space launch vehicles. Background information on the use of aerotow for a space launch vehicle is presented, and the aerotow system used in this demonstration is described. The ground tests, analytical studies, and flight planning used to predict system behavior and to enhance flight safety are detailed. The instrumentation suite and flight test maneuvers flown are discussed, preliminary performance is assessed, and flight test results are compared with the preflight predictions.

  13. A Randomized Controlled Pilot Intervention Study of a Mindfulness-Based Self-Leadership Training (MBSLT) on Stress and Performance.

    PubMed

    Sampl, Juliane; Maran, Thomas; Furtner, Marco R

    2017-01-01

    The present randomized pilot intervention study examines the effects of a mindfulness-based self-leadership training (MBSLT) specifically developed for academic achievement situations. Both mindfulness and self-leadership have a strong self-regulatory focus and are helpful in terms of stress resilience and performance enhancements. Based on several theoretical points of contact and a specific interplay between mindfulness and self-leadership, the authors developed an innovative intervention program that improves mood as well as performance in a real academic setting. The intervention was conducted as a randomized controlled study over 10 weeks. The purpose was to analyze the effects on perceived stress, test anxiety, academic self-efficacy, and the performance of students by comparing an intervention and control group ( n  = 109). Findings demonstrated significant effects on mindfulness, self-leadership, academic self-efficacy, and academic performance improvements in the intervention group. Results showed that the intervention group reached significantly better grade point averages than the control group. Moreover, the MBSLT over time led to a reduction of test anxiety in the intervention group compared to the control group. Furthermore, while participants of the control group showed an increase in stress over time, participants of the intervention group maintained constant stress levels over time. The combination of mindfulness and self-leadership addressed both positive effects on moods and on objective academic performance. The effects demonstrate the great potential of combining mindfulness with self-leadership to develop a healthy self-regulatory way of attaining achievement-related goals and succeeding in high-stress academic environments.

  14. Harnessing Diversity towards the Reconstructing of Large Scale Gene Regulatory Networks

    PubMed Central

    Yamanaka, Ryota; Kitano, Hiroaki

    2013-01-01

    Elucidating gene regulatory network (GRN) from large scale experimental data remains a central challenge in systems biology. Recently, numerous techniques, particularly consensus driven approaches combining different algorithms, have become a potentially promising strategy to infer accurate GRNs. Here, we develop a novel consensus inference algorithm, TopkNet that can integrate multiple algorithms to infer GRNs. Comprehensive performance benchmarking on a cloud computing framework demonstrated that (i) a simple strategy to combine many algorithms does not always lead to performance improvement compared to the cost of consensus and (ii) TopkNet integrating only high-performance algorithms provide significant performance improvement compared to the best individual algorithms and community prediction. These results suggest that a priori determination of high-performance algorithms is a key to reconstruct an unknown regulatory network. Similarity among gene-expression datasets can be useful to determine potential optimal algorithms for reconstruction of unknown regulatory networks, i.e., if expression-data associated with known regulatory network is similar to that with unknown regulatory network, optimal algorithms determined for the known regulatory network can be repurposed to infer the unknown regulatory network. Based on this observation, we developed a quantitative measure of similarity among gene-expression datasets and demonstrated that, if similarity between the two expression datasets is high, TopkNet integrating algorithms that are optimal for known dataset perform well on the unknown dataset. The consensus framework, TopkNet, together with the similarity measure proposed in this study provides a powerful strategy towards harnessing the wisdom of the crowds in reconstruction of unknown regulatory networks. PMID:24278007

  15. Design and Testing of a Liquid Nitrous Oxide and Ethanol Fueled Rocket Engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Youngblood, Stewart

    A small-scale, bi-propellant, liquid fueled rocket engine and supporting test infrastructure were designed and constructed at the Energetic Materials Research and Testing Center (EMRTC). This facility was used to evaluate liquid nitrous oxide and ethanol as potential rocket propellants. Thrust and pressure measurements along with high-speed digital imaging of the rocket exhaust plume were made. This experimental data was used for validation of a computational model developed of the rocket engine tested. The developed computational model was utilized to analyze rocket engine performance across a range of operating pressures, fuel-oxidizer mixture ratios, and outlet nozzle configurations. A comparative study ofmore » the modeling of a liquid rocket engine was performed using NASA CEA and Cantera, an opensource equilibrium code capable of being interfaced with MATLAB. One goal of this modeling was to demonstrate the ability of Cantera to accurately model the basic chemical equilibrium, thermodynamics, and transport properties for varied fuel and oxidizer operating conditions. Once validated for basic equilibrium, an expanded MATLAB code, referencing Cantera, was advanced beyond CEAs capabilities to predict rocket engine performance as a function of supplied propellant flow rate and rocket engine nozzle dimensions. Cantera was found to comparable favorably to CEA for making equilibrium calculations, supporting its use as an alternative to CEA. The developed rocket engine performs as predicted, demonstrating the developedMATLAB rocket engine model was successful in predicting real world rocket engine performance. Finally, nitrous oxide and ethanol were shown to perform well as rocket propellants, with specific impulses experimentally recorded in the range of 250 to 260 seconds.« less

  16. Using Comprehensive Video-Module Instruction as an Alternative Approach for Teaching IUD Insertion.

    PubMed

    Garcia-Rodriguez, Juan Antonio; Donnon, Tyrone

    2016-01-01

    Family medicine clinicians and residents have increasing educational and work demands that have made it difficult to provide and access training on specific procedures such as IUD insertion. The purpose of this study was to determine whether the use of video-module instruction could provide residents with the necessary knowledge and skills to perform an IUD insertion correctly when compared with the traditional form of instruction, which is a lecture-demonstration session provided by an academic gynecologist. Thirty-nine family medicine residents participated in the study during the induction period at the beginning of their residency program in July 2012 at the University of Calgary. A randomized, two group pretest/posttest experimental research design was used to compare the procedural knowledge and skills performance (posttest only) of residents trained using an alternative instructional intervention (video-module teaching) with the traditional lecture-demonstration approach to teaching IUD insertion. Both teaching methods were effective in providing procedural knowledge instruction, and the paired-samples t tests results were almost identical: t (37)=1.35. On the other hand, performance scores were significantly higher in the video-module group: t (37)=2.37, 95% CI (0.61, 8.00), with a mean difference in performance of 4.31. There were no significant differences in residents' satisfaction scores, and there was no correlation between the different scores and sex or age or between performance and level of satisfaction. This video-module instruction is an effective method to provide comprehensive IUD insertion training, and the psychomotor skills gain (performance component) was significantly higher than the traditional method of instruction.

  17. Pilot physiology, cognition and flight performance during flight simulation exposed to a 3810-m hypoxic condition.

    PubMed

    Peacock, Corey A; Weber, Raymond; Sanders, Gabriel J; Seo, Yongsuk; Kean, David; Pollock, Brandon S; Burns, Keith J; Cain, Mark; LaScola, Phillip; Glickman, Ellen L

    2017-03-01

    Hypoxia is a physiological state defined as a reduction in the distribution of oxygen to the tissues of the body. It has been considered a major factor in aviation safety worldwide because of its potential for pilot disorientation. Pilots are able to operate aircrafts up to 3810 m without the use of supplemental oxygen and may exhibit symptoms associated with hypoxia. To determine the effects of 3810 m on physiology, cognition and performance in pilots during a flight simulation. Ten healthy male pilots engaged in a counterbalanced experimental protocol comparing a 0-m normoxic condition (NORM) with a 3810-m hypoxic condition (HYP) on pilot physiology, cognition and flight performance. Repeated-measures analysis of variance demonstrated a significant (p ≤ 0.05) time by condition interaction for physiological and cognitive alterations during HYP. A paired-samples t test demonstrated no differences in pilot performance (p ≥ 0.05) between conditions. Pilots exhibited physiological and cognitive impairments; however, pilot performance was not affected by HYP.

  18. Comparative Physiology of Fatigue.

    PubMed

    Jones, James H

    2016-11-01

    This review attempts to provide insights into factors associated with fatigue in human and nonhuman animals by using the two fundamental approaches of comparative physiology: determining common principles that govern structure and function in animals that are relatively invariant between animals and evaluating animals that have been highly adapted by natural selection to demonstrate extreme performance. In this review, I approach the topic of fatigue by considering factors that are associated with its reciprocal or inverse or duration of sustained performance before fatigue sets in to end the performance. The two general factors that I consider that affect endurance time more than any other are body temperature and body mass. The former affects endurance time because of thermodynamic effects on chemical reaction rates and metabolism; the latter acts through the mechanism of allometry or scaling. The examples of extreme animal performance that I discuss are two examples of bird migration, the diving performance of marine mammals, and the unique relationship that governs energy cost of locomotion in hopping kangaroos.

  19. Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens.

    PubMed

    Song, In Seok; Yoon, Sam Young; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon

    2016-04-01

    To compare visual performance and higher order aberrations (HOAs) based on the position of the near segment in eyes with rotationally asymmetric multifocal intraocular lenses (IOLs). Asymmetric multifocal IOLs (Lentis Mplus LS-313; Oculentis Optikgeräte GmbH, Wetzlar, Germany) were implanted with the near segment positioned either inferiorly, superiorly, or temporally. Uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuity, corrected distance visual acuity (CDVA), and distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuity, contrast sensitivity, HOAs, and subjective symptom questionnaires were compared at 1 month postoperatively. Forty-five eyes from 45 patients were evaluated (n = 25, 9, and 11 eyes in the inferior, superior, and temporal groups, respectively). No significant differences in UDVA, UIVA, UNVA, CDVA, DCIVA, or DCNVA were found between the three groups (P > .05). The temporal group showed the best results in UDVA, CDVA, and DCNVA, but the inferior group showed the best results in DCIVA and UNVA and the superior group showed the best results in UIVA. Contrast sensitivity and the subjective symptom questionnaire also did not demonstrate any significant differences (P > .05). Total HOA and spherical aberration did not demonstrate any statistically significant differences (P > .05), but vertical coma and horizontal coma demonstrated significant differences based on near segment position (P < .001). The position of the near segment in eyes with rotationally asymmetric multifocal IOLs demonstrates no significant effect on visual performance. Copyright 2016, SLACK Incorporated.

  20. Increased fusiform area activation in schizophrenia during processing of spatial frequency-degraded faces, as revealed by fMRI.

    PubMed

    Silverstein, S M; All, S D; Kasi, R; Berten, S; Essex, B; Lathrop, K L; Little, D M

    2010-07-01

    People with schizophrenia demonstrate perceptual organization impairments, and these are thought to contribute to their face processing difficulties. We examined the neural substrates of emotionally neutral face processing in schizophrenia by investigating neural activity under three stimulus conditions: faces characterized by the full spectrum of spatial frequencies, faces with low spatial frequency information removed [high spatial frequency (HSF) condition], and faces with high spatial frequency information removed [low spatial frequency (LSF) condition]. Face perception in the HSF condition is more reliant on local feature processing whereas perception in the LSF condition requires greater reliance on global form processing. Past studies of perceptual organization in schizophrenia indicate that patients perform relatively more poorly with degraded stimuli but also that, when global information is absent, patients may perform better than controls because of their relatively increased ability to initially process individual features. Therefore, we hypothesized that people with schizophrenia (n=14) would demonstrate greater face processing difficulties than controls (n=13) in the LSF condition, whereas they would demonstrate a smaller difference or superior performance in the HSF condition. In a gender-discrimination task, behavioral data indicated high levels of accuracy for both groups, with a trend toward an interaction involving higher patient performance in the HSF condition and poorer patient performance in the LSF condition. Patients demonstrated greater activity in the fusiform gyrus compared to controls in both degraded conditions. These data suggest that impairments in basic integration abilities may be compensated for by relatively increased activity in this region.

  1. Comparative study of passively Q-switched c-cut Nd:YVO4/Nd:YAG lasers based on CVD graphene and controlled operation

    NASA Astrophysics Data System (ADS)

    Jia, Fuqiang; Liu, Pei; Li, Kang; Chen, Hao; Cheng, Yongjie; Cai, Zhiping; Copner, Nigel

    2017-07-01

    In this paper, a comparative study of passively Q-switched c-cut Nd:YVO4 and Nd:YAG lasers using four different layers CVD graphene as saturable absorber are demonstrated experimentally for the first time. Moreover, it is successful to accurately control the frequency of repetition rates of the CVD graphern passively Q-switched lasers by pulsed pump. The impacts of laser materials, layers of CVD graphene and cavity length on output parameters are investigated intensively as well, the result shows that the c-cut Nd:YVO4 is a promising laser media compared with Nd:YAG for passively Q-switched lasers based on CVD graphene, as it has better performances in pulse width, pulse energy and peak power. A useful and cost-effective way to generate stable pulsed lasers by CVD graphene or other novel saturable materials are demonstrated.

  2. Biomechanical Comparison of Single- Versus Double-Row Capsulolabral Repair for Shoulder Instability: A Review.

    PubMed

    Yousif, Matthew John; Bicos, James

    2017-12-01

    The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Narrative review. A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed.

  3. Tensile strength of biological fibrin sealants: a comparative study.

    PubMed

    Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel

    2012-08-01

    Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. A Comparative Study of High and Low Fidelity Fan Models for Turbofan Engine System Simulation

    NASA Technical Reports Server (NTRS)

    Reed, John A.; Afjeh, Abdollah A.

    1991-01-01

    In this paper, a heterogeneous propulsion system simulation method is presented. The method is based on the formulation of a cycle model of a gas turbine engine. The model includes the nonlinear characteristics of the engine components via use of empirical data. The potential to simulate the entire engine operation on a computer without the aid of data is demonstrated by numerically generating "performance maps" for a fan component using two flow models of varying fidelity. The suitability of the fan models were evaluated by comparing the computed performance with experimental data. A discussion of the potential benefits and/or difficulties in connecting simulations solutions of differing fidelity is given.

  5. Principles and performance of tapered fiber lasers: from uniform to flared geometry.

    PubMed

    Kerttula, Juho; Filippov, Valery; Chamorovskii, Yuri; Ustimchik, Vasily; Golant, Konstantin; Okhotnikov, Oleg G

    2012-10-10

    We have studied the recently demonstrated concept of fiber lasers based on active tapered double-clad fiber (T-DCF) in copropagating and counterpropagating configurations, both theoretically and experimentally, and compared the performance to fiber lasers based on conventional cylindrical fibers in end-pumped configurations. Specific properties of T-DCFs were considered theoretically using a rate-equation model developed for tapered fibers, and a detailed comparative study was carried out experimentally. Furthermore, we have studied mode coupling effects in long adiabatic tapers due to coiling and local bending. The results allow us to conclude that, with proper fiber design, the T-DCF technology offers a high-potential alternative for bright, cost-effective fiber devices.

  6. The Effects of High- and Low-Anxiety Training on the Anticipation Judgments of Elite Performers.

    PubMed

    Alder, David; Ford, Paul R; Causer, Joe; Williams, A Mark

    2016-02-01

    We examined the effects of high- versus low-anxiety conditions during video-based training of anticipation judgments using international-level badminton players facing serves and the transfer to high-anxiety and field-based conditions. Players were assigned to a high-anxiety training (HA), low-anxiety training (LA) or control group (CON) in a pretraining-posttest design. In the pre- and posttest, players anticipated serves from video and on court under high- and low-anxiety conditions. In the video-based high-anxiety pretest, anticipation response accuracy was lower and final fixations shorter when compared with the low-anxiety pretest. In the low-anxiety posttest, HA and LA demonstrated greater accuracy of judgments and longer final fixations compared with pretest and CON. In the high-anxiety posttest, HA maintained accuracy when compared with the low-anxiety posttest, whereas LA had lower accuracy. In the on-court posttest, the training groups demonstrated greater accuracy of judgments compared with the pretest and CON.

  7. Performance evaluation of a burst-mode EDFA in an optical packet and circuit integrated network.

    PubMed

    Shiraiwa, Masaki; Awaji, Yoshinari; Furukawa, Hideaki; Shinada, Satoshi; Puttnam, Benjamin J; Wada, Naoya

    2013-12-30

    We experimentally investigate the performance of burst-mode EDFA in an optical packet and circuit integrated system. In such networks, packets and light paths can be dynamically assigned to the same fibers, resulting in gain transients in EDFAs throughout the network that can limit network performance. Here, we compare the performance of a 'burst-mode' EDFA (BM-EDFA), employing transient suppression techniques and optical feedback, with conventional EDFAs, and those using automatic gain control and previous BM-EDFA implementations. We first measure gain transients and other impairments in a simplified set-up before making frame error-rate measurements in a network demonstration.

  8. Reserve Li/SOC12 Battery Safety Testing

    NASA Technical Reports Server (NTRS)

    Dils, C. T.; Garoutte, K. F.

    1984-01-01

    A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

  9. Robotic Assistance Enables Inexperienced Surgeons to Perform Unicompartmental Knee Arthroplasties on Dry Bone Models with Accuracy Superior to Conventional Methods

    PubMed Central

    Masjedi, Milad; Andrews, Barry; Cobb, Justin

    2013-01-01

    Robotic systems have been shown to improve unicompartmental knee arthroplasty (UKA) component placement accuracy compared to conventional methods when used by experienced surgeons. We aimed to determine whether inexperienced UKA surgeons can position components accurately using robotic assistance when compared to conventional methods and to demonstrate the effect repetition has on accuracy. Sixteen surgeons were randomised to an active constraint robot or conventional group performing three UKAs over three weeks. Implanted component positions and orientations were compared to planned component positions in six degrees of freedom for both femoral and tibial components. Mean procedure time decreased for both robot (37.5 mins to 25.7 mins) (P = 0.002) and conventional (33.8 mins to 21.0 mins) (P = 0.002) groups by attempt three indicating the presence of a learning curve; however, neither group demonstrated changes in accuracy. Mean compound rotational and translational errors were lower in the robot group compared to the conventional group for both components at all attempts for which rotational error differences were significant at every attempt. The conventional group's positioning remained inaccurate even with repeated attempts although procedure time improved. In comparison, by limiting inaccuracies inherent in conventional equipment, robotic assistance enabled surgeons to achieve precision and accuracy when positioning UKA components irrespective of their experience. PMID:23862069

  10. Genome-Wide Comparative Gene Family Classification

    PubMed Central

    Frech, Christian; Chen, Nansheng

    2010-01-01

    Correct classification of genes into gene families is important for understanding gene function and evolution. Although gene families of many species have been resolved both computationally and experimentally with high accuracy, gene family classification in most newly sequenced genomes has not been done with the same high standard. This project has been designed to develop a strategy to effectively and accurately classify gene families across genomes. We first examine and compare the performance of computer programs developed for automated gene family classification. We demonstrate that some programs, including the hierarchical average-linkage clustering algorithm MC-UPGMA and the popular Markov clustering algorithm TRIBE-MCL, can reconstruct manual curation of gene families accurately. However, their performance is highly sensitive to parameter setting, i.e. different gene families require different program parameters for correct resolution. To circumvent the problem of parameterization, we have developed a comparative strategy for gene family classification. This strategy takes advantage of existing curated gene families of reference species to find suitable parameters for classifying genes in related genomes. To demonstrate the effectiveness of this novel strategy, we use TRIBE-MCL to classify chemosensory and ABC transporter gene families in C. elegans and its four sister species. We conclude that fully automated programs can establish biologically accurate gene families if parameterized accordingly. Comparative gene family classification finds optimal parameters automatically, thus allowing rapid insights into gene families of newly sequenced species. PMID:20976221

  11. Functional magnetic resonance imaging study comparing rhythmic finger tapping in children and adults.

    PubMed

    De Guio, François; Jacobson, Sandra W; Molteno, Christopher D; Jacobson, Joseph L; Meintjes, Ernesta M

    2012-02-01

    This study compared brain activation during unpaced rhythmic finger tapping in 12-year-old children with that of adults. Subjects pressed a button at a pace initially indicated by a metronome (12 consecutive tones), and then continued for 16 seconds of unpaced tapping to provide an assessment of their ability to maintain a steady rhythm. These analyses focused on the superior vermis of the cerebellum, which is known to play a key role in timing. Twelve adults and 12 children performed this rhythmic finger tapping task in a 3 T scanner. Whole-brain analyses were performed in Brain Voyager, with a random-effects analysis of variance using a general linear model. A dedicated cerebellar atlas was used to localize cerebellar activations. As in adults, unpaced rhythmic finger tapping in children demonstrated activations in the primary motor cortex, premotor cortex, and cerebellum. However, overall activation was different, in that adults demonstrated much more deactivation in response to the task, particularly in the occipital and frontal cortices. The other main differences involved the additional recruitment of motor and premotor areas in children compared with adults, and increased activity in the vermal region of the cerebellum. These findings suggest that the timing component of the unpaced rhythmic finger tapping task is less efficient and automatic in children, who need to recruit the superior vermis more intensively to maintain the rhythm, although they performed somewhat more poorly than adults. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. A Full Navier-Stokes Analysis of Subsonic Diffuser of a Bifurcated 70/30 Supersonic Inlet for High Speed Civil Transport Application

    NASA Technical Reports Server (NTRS)

    Kapoor, Kamlesh; Anderson, Bernhard H.; Shaw, Robert J.

    1994-01-01

    A full Navier-Stokes analysis was performed to evaluate the performance of the subsonic diffuser of a NASA Lewis Research Center 70/30 mixed-compression bifurcated supersonic inlet for high speed civil transport application. The PARC3D code was used in the present study. The computations were also performed when approximately 2.5 percent of the engine mass flow was allowed to bypass through the engine bypass doors. The computational results were compared with the available experimental data which consisted of detailed Mach number and total pressure distribution along the entire length of the subsonic diffuser. The total pressure recovery, flow distortion, and crossflow velocity at the engine face were also calculated. The computed surface ramp and cowl pressure distributions were compared with experiments. Overall, the computational results compared well with experimental data. The present CFD analysis demonstrated that the bypass flow improves the total pressure recovery and lessens flow distortions at the engine face.

  13. A comparative study of one-step and two-step approaches for MAPbI3 perovskite layer and its influence on the performance of mesoscopic perovskite solar cell

    NASA Astrophysics Data System (ADS)

    Wang, Minhuan; Feng, Yulin; Bian, Jiming; Liu, Hongzhu; Shi, Yantao

    2018-01-01

    The mesoscopic perovskite solar cells (M-PSCs) were synthesized with MAPbI3 perovskite layers as light harvesters, which were grown with one-step and two-step solution process, respectively. A comparative study was performed through the quantitative correlation of resulting device performance and the crystalline quality of perovskite layers. Comparing with the one-step counterpart, a pronounced improvement in the steady-state power conversion efficiencies (PCEs) by 56.86% was achieved with two-step process, which was mainly resulted from the significant enhancement in fill factor (FF) from 48% to 77% without sacrificing the open circuit voltage (Voc) and short circuit current (Jsc). The enhanced FF was attributed to the reduced non-radiative recombination channels due to the better crystalline quality and larger grain size with the two-step processed perovskite layer. Moreover, the superiority of two-step over one-step process was demonstrated with rather good reproducibility.

  14. Driver performance and attention allocation in use of logo signs on freeway exit ramps.

    PubMed

    Zahabi, Maryam; Machado, Patricia; Lau, Mei Ying; Deng, Yulin; Pankok, Carl; Hummer, Joseph; Rasdorf, William; Kaber, David B

    2017-11-01

    The objective of this research was to quantify the effects of driver age, ramp signage configuration, including number of panels, logo format and sign familiarity, on driver performance and attention allocation when exiting freeways. Sixty drivers participated in a simulator study and analysis of variance models were used to assess response effects of the controlled manipulations. Results revealed elderly drivers to demonstrate worse performance and conservative control strategies as compared to middle-aged and young drivers. Elderly drivers also exhibited lower off-road fixation frequency and shorter off-road glance durations compared to middle-aged and young drivers. In general, drivers adopted a more conservative strategy when exposed to nine-panel signs as compared to six-panel signs and were more accurate in target detection when searching six-panels vs. nine and with familiar vs. unfamiliar logos. These findings provide an applicable guide for agency design of freeway ramp signage accounting for driver demographics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Contemporary Surgical Trends in the Management of Symptomatic Meniscal Tears among United States Military Servicemembers from 2010 to 2015.

    PubMed

    Pekari, Timothy B; Wang, Kevin C; Cotter, Eric J; Kusnezov, Nicholas; Waterman, Brian R

    2018-03-07

    The purpose of this investigation is to report on trends over time in the treatment of meniscal pathology among military orthopaedic surgeons, as well as to evaluate the impact of patient demographics and concomitant procedure on the type of meniscal procedure performed. We performed a retrospective analysis of all active-duty United States military servicemembers who underwent a meniscal procedure from 2010 to 2015 within the Military Health System. Patient demographics and surgical variables were extracted from the electronic medical record. Treatments were categorized by location and by type of intervention (i.e., repair or debridement). Chi-square and linear regression analyses were performed to identify temporal trends in meniscal procedures and factors that were correlated with the type of meniscal procedure performed. Out of 29,571 meniscal procedures analyzed, partial meniscectomy was performed in 81.3% ( n  = 24,343) of cases, meniscal repair in 20.3% ( n  = 6,073), and meniscus allograft transplantation (MAT) in 0.7% ( n  = 206). The rates of debridement, repair, and concomitant surgeries did not demonstrate any significant temporal trends, whereas MAT demonstrated a significant decrease in overall utilization. Nearly two-thirds of all meniscal procedures were performed in the medial compartment. MAT occurred equally between the medial and lateral compartments. Lateral meniscal lesions demonstrated significantly higher rates of debridement. With each year of advancing age, there was a 3.7% increasing likelihood of meniscectomy and 6.5% decreasing likelihood of repair. Females were more likely to undergo meniscal repair than males. Patients in the military population were more likely to undergo meniscal repair compared with previously reported rates in the civilian population. In this physically active cohort of nearly 30,000 military patients, 1 in 5 meniscal tears were treated with meniscal repair. Meniscal repairs were performed at a higher rate for all age groups compared with previously reported rates in the civilian population. Further research is required to elucidate the causative factors behind these differences and the effect on postoperative outcomes. IV, cross-sectional study. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Kinetic performance comparison of fully and superficially porous particles with a particle size of 5 µm: intrinsic evaluation and application to the impurity analysis of griseofulvin.

    PubMed

    Kahsay, Getu; Broeckhoven, Ken; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre

    2014-05-01

    After the great commercial success of sub-3 µm superficially porous particles, vendors are now also starting to commercialize 5 µm superficially porous particles, as an alternative to their fully porous counterparts which are routinely used in pharmaceutical analysis. In this study, the performance of 5 µm superficially porous particles was compared to that of fully porous 5 µm particles in terms of efficiency, separation performance and loadability on a conventional HPLC instrument. Van Deemter and kinetic plots were first used to evaluate the efficiency and performance of both particle types using alkylphenones as a test mixture. The van Deemter and kinetic plots showed that the superficially porous particles provide a superior kinetic performance compared to the fully porous particles over the entire relevant range of separation conditions, when both support types were evaluated at the same operating pressure. The same observations were made both for isocratic and gradient analysis. The superior performance was further demonstrated for the separation of a pharmaceutical compound (griseofulvin) and its impurities, where a gain in analysis time of around 2 could be obtained using the superficially porous particles. Finally, both particle types were evaluated in terms of loadability by plotting the resolution of the active pharmaceutical ingredient and its closest impurity as a function of the signal-to-noise ratio obtained for the smallest impurity. It was demonstrated that the superficially porous particles show better separation performance for griseofulvin and its impurities without significantly compromising sensitivity due to loadability issues in comparison with their fully porous counterparts. Moreover these columns can be used on conventional equipment without modifications to obtain a significant improvement in analysis time. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Research performance of AACSB accredited institutions in Taiwan: before versus after accreditation.

    PubMed

    Ke, Shih-Wen; Lin, Wei-Chao; Tsai, Chih-Fong

    2016-01-01

    More and more universities are receiving accreditation from the Association to Advance Collegiate Schools of Business (AACSB), which is an international association for promoting quality teaching and learning at business schools. To be accredited, the schools are required to meet a number of standards ensuring that certain levels of teaching quality and students' learning are met. However, there are a variety of points of view espoused in the literature regarding the relationship between research and teaching, some studies have demonstrated that research and teaching these are complementary elements of learning, but others disagree with these findings. Unlike past such studies, we focus on analyzing the research performance of accredited schools during the period prior to and after receiving accreditation. The objective is to answer the question as to whether performance has been improved by comparing the same school's performance before and after accreditation. In this study, four AACSB accredited universities in Taiwan are analyzed, including one teaching oriented and three research oriented universities. Research performance is evaluated by comparing seven citation statistics, the number of papers published, number of citations, average number of citations per paper, average citations per year, h-index (annual), h-index, and g-index. The analysis results show that business schools demonstrated enhanced research performance after AACSB accreditation, but in most accredited schools the proportion of faculty members not actively doing research is larger than active ones. This study shows that the AACSB accreditation has a positive impact on research performance. The findings can be used as a reference for current non-accredited schools whose research goals are to improve their research productivity and quality.

  18. Filling the glass: Effects of a positive psychology intervention on executive task performance in chronic pain patients.

    PubMed

    Boselie, J J L M; Vancleef, L M G; Peters, M L

    2018-03-24

    Chronic pain is associated with emotional problems as well as difficulties in cognitive functioning. Prior experimental studies have shown that optimism, the tendency to expect that good things happen in the future, and positive emotions can counteract pain-induced task performance deficits in healthy participants. More specifically, induced optimism was found to buffer against the negative effects of experimental pain on executive functioning. This clinical experiment examined whether this beneficial effect can be extended to a chronic pain population. Patients (N = 122) were randomized to a positive psychology Internet-based intervention (PPI; n = 74) or a waiting list control condition (WLC; n = 48). The PPI consisted of positive psychology exercises that particularly target optimism, positive emotions and self-compassion. Results demonstrated that patients in the PPI condition scored higher on happiness, optimism, positive future expectancies, positive affect, self-compassion and ability to live a desired life despite pain, and scored lower on pain catastrophizing, depression and anxiety compared to patients in the WLC condition. However, executive task performance did not improve following completion of the PPI, compared to the WLC condition. Despite the lack of evidence that positive emotions and optimism can improve executive task performance in chronic pain patients, this study did convincingly demonstrate that it is possible to increase positive emotions and optimism in chronic pain patients with an online positive psychology intervention. It is imperative to further explore amendable psychological factors that may reduce the negative impact of pain on executive functioning. We demonstrated that an Internet-based positive psychology intervention strengthens optimism and positive emotions in chronic pain patients. These emotional improvements are not associated with improved executive task performance. As pain itself often cannot be relieved, it is imperative to have techniques to reduce the burden of living with chronic pain. © 2018 The Authors. European Journal of Pain published by John Wiley & Sons Ltd on behalf of European Pain Federation -EFIC®.

  19. Virtual reality simulator training for laparoscopic colectomy: what metrics have construct validity?

    PubMed

    Shanmugan, Skandan; Leblanc, Fabien; Senagore, Anthony J; Ellis, C Neal; Stein, Sharon L; Khan, Sadaf; Delaney, Conor P; Champagne, Bradley J

    2014-02-01

    Virtual reality simulation for laparoscopic colectomy has been used for training of surgical residents and has been considered as a model for technical skills assessment of board-eligible colorectal surgeons. However, construct validity (the ability to distinguish between skill levels) must be confirmed before widespread implementation. This study was designed to specifically determine which metrics for laparoscopic sigmoid colectomy have evidence of construct validity. General surgeons that had performed fewer than 30 laparoscopic colon resections and laparoscopic colorectal experts (>200 laparoscopic colon resections) performed laparoscopic sigmoid colectomy on the LAP Mentor model. All participants received a 15-minute instructional warm-up and had never used the simulator before the study. Performance was then compared between each group for 21 metrics (procedural, 14; intraoperative errors, 7) to determine specifically which measurements demonstrate construct validity. Performance was compared with the Mann-Whitney U-test (p < 0.05 was significant). Fifty-three surgeons; 29 general surgeons, and 24 colorectal surgeons enrolled in the study. The virtual reality simulators for laparoscopic sigmoid colectomy demonstrated construct validity for 8 of 14 procedural metrics by distinguishing levels of surgical experience (p < 0.05). The most discriminatory procedural metrics (p < 0.01) favoring experts were reduced instrument path length, accuracy of the peritoneal/medial mobilization, and dissection of the inferior mesenteric artery. Intraoperative errors were not discriminatory for most metrics and favored general surgeons for colonic wall injury (general surgeons, 0.7; colorectal surgeons, 3.5; p = 0.045). Individual variability within the general surgeon and colorectal surgeon groups was not accounted for. The virtual reality simulators for laparoscopic sigmoid colectomy demonstrated construct validity for 8 procedure-specific metrics. However, using virtual reality simulator metrics to detect intraoperative errors did not discriminate between groups. If the virtual reality simulator continues to be used for the technical assessment of trainees and board-eligible surgeons, the evaluation of performance should be limited to procedural metrics.

  20. Roll-to-roll fabrication of large scale and regular arrays of three-dimensional nanospikes for high efficiency and flexible photovoltaics

    PubMed Central

    Leung, Siu-Fung; Gu, Leilei; Zhang, Qianpeng; Tsui, Kwong-Hoi; Shieh, Jia-Min; Shen, Chang-Hong; Hsiao, Tzu-Hsuan; Hsu, Chin-Hung; Lu, Linfeng; Li, Dongdong; Lin, Qingfeng; Fan, Zhiyong

    2014-01-01

    Three-dimensional (3-D) nanostructures have demonstrated enticing potency to boost performance of photovoltaic devices primarily owning to the improved photon capturing capability. Nevertheless, cost-effective and scalable fabrication of regular 3-D nanostructures with decent robustness and flexibility still remains as a challenging task. Meanwhile, establishing rational design guidelines for 3-D nanostructured solar cells with the balanced electrical and optical performance are of paramount importance and in urgent need. Herein, regular arrays of 3-D nanospikes (NSPs) were fabricated on flexible aluminum foil with a roll-to-roll compatible process. The NSPs have precisely controlled geometry and periodicity which allow systematic investigation on geometry dependent optical and electrical performance of the devices with experiments and modeling. Intriguingly, it has been discovered that the efficiency of an amorphous-Si (a-Si) photovoltaic device fabricated on NSPs can be improved by 43%, as compared to its planar counterpart, in an optimal case. Furthermore, large scale flexible NSP solar cell devices have been fabricated and demonstrated. These results not only have shed light on the design rules of high performance nanostructured solar cells, but also demonstrated a highly practical process to fabricate efficient solar panels with 3-D nanostructures, thus may have immediate impact on thin film photovoltaic industry. PMID:24603964

  1. Roll-to-roll fabrication of large scale and regular arrays of three-dimensional nanospikes for high efficiency and flexible photovoltaics.

    PubMed

    Leung, Siu-Fung; Gu, Leilei; Zhang, Qianpeng; Tsui, Kwong-Hoi; Shieh, Jia-Min; Shen, Chang-Hong; Hsiao, Tzu-Hsuan; Hsu, Chin-Hung; Lu, Linfeng; Li, Dongdong; Lin, Qingfeng; Fan, Zhiyong

    2014-03-07

    Three-dimensional (3-D) nanostructures have demonstrated enticing potency to boost performance of photovoltaic devices primarily owning to the improved photon capturing capability. Nevertheless, cost-effective and scalable fabrication of regular 3-D nanostructures with decent robustness and flexibility still remains as a challenging task. Meanwhile, establishing rational design guidelines for 3-D nanostructured solar cells with the balanced electrical and optical performance are of paramount importance and in urgent need. Herein, regular arrays of 3-D nanospikes (NSPs) were fabricated on flexible aluminum foil with a roll-to-roll compatible process. The NSPs have precisely controlled geometry and periodicity which allow systematic investigation on geometry dependent optical and electrical performance of the devices with experiments and modeling. Intriguingly, it has been discovered that the efficiency of an amorphous-Si (a-Si) photovoltaic device fabricated on NSPs can be improved by 43%, as compared to its planar counterpart, in an optimal case. Furthermore, large scale flexible NSP solar cell devices have been fabricated and demonstrated. These results not only have shed light on the design rules of high performance nanostructured solar cells, but also demonstrated a highly practical process to fabricate efficient solar panels with 3-D nanostructures, thus may have immediate impact on thin film photovoltaic industry.

  2. Comparison of SeaWinds Backscatter Imaging Algorithms

    PubMed Central

    Long, David G.

    2017-01-01

    This paper compares the performance and tradeoffs of various backscatter imaging algorithms for the SeaWinds scatterometer when multiple passes over a target are available. Reconstruction methods are compared with conventional gridding algorithms. In particular, the performance and tradeoffs in conventional ‘drop in the bucket’ (DIB) gridding at the intrinsic sensor resolution are compared to high-spatial-resolution imaging algorithms such as fine-resolution DIB and the scatterometer image reconstruction (SIR) that generate enhanced-resolution backscatter images. Various options for each algorithm are explored, including considering both linear and dB computation. The effects of sampling density and reconstruction quality versus time are explored. Both simulated and actual data results are considered. The results demonstrate the effectiveness of high-resolution reconstruction using SIR as well as its limitations and the limitations of DIB and fDIB. PMID:28828143

  3. Enhancement of Gas Barrier Properties of CFRP Laminates Fabricated Using Thin-Ply Prepregs

    NASA Astrophysics Data System (ADS)

    横関, 智弘; 高木, 智宏; 吉村, 彰記; Ogasawara, Toshio; 荻原, 慎二

    Composite laminates manufactured using thin-ply prepregs are expected to have superior resistance properties against microcracking compared to those using standard prepregs. In this study, comparative investigations are presented on the microcrack accumulation and gas leakage characteristics of CFRP laminates fabricated using standard and thin-ply prepregs, consisting of high-performance carbon fiber and toughened epoxy, as a fundamental research on the cryogenic composite tanks for future space vehicles. It was shown that laminates using thin-ply prepregs exhibited much higher strain at microcrack initiation compared to those using standard prepregs at room and cryogenic temperatures. In addition, helium gas leak tests using CFRP laminated tubular specimens subjected to quasi-static tension loadings were performed. It was demonstrated that CFRP laminates using thin-ply prepregs have higher gas barrier properties than those using standard prepregs.

  4. A European multicenter study on the analytical performance of the VERIS HBV assay.

    PubMed

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. iPads and LCDs show similar performance in the detection of pulmonary nodules

    NASA Astrophysics Data System (ADS)

    McEntee, Mark F.; Lowe, Joanna; Butler, Marie Louise; Pietrzyk, Mariusz; Evanoff, Michael G.; Ryan, John; Brennan, Patrick C.; Rainford, Louise A.

    2012-02-01

    In February 2011 the University of Chicago Medical School distributed iPads to its trainee doctors for use when reviewing clinical information and images on the ward or clinics. The use of tablet computing devices is becoming widespread in medicine with Apple™ heralding them as "revolutionary" in medicine. The question arises, just because it is technical achievable to use iPads for clinical evaluation of images, should we do so? The current work assesses the diagnostic efficacy of iPads when compared with LCD secondary display monitors for identifying lung nodules on chest x-rays. Eight examining radiologists of the American Board of Radiology were involved in the assessment, reading chest images on both the iPad and the an off-the-shelf LCD monitor. Thirty chest images were shown to each observer, of which 15 had one or more lung nodules. Radiologists were asked to locate the nodules and score how confident they were with their decision on a scale of 1-5. An ROC and JAFROC analysis was performed and modalities were compared using DBM MRMC. The results demonstrate no significant differences in performance between the iPad and the LCD for the ROC AUC (p<0.075) or JAFROC FOM (p<0.059) for random readers and random cases. Sample size estimation showed that this result is significant at a power of 0.8 and an effect size of 0.05 for ROC and 0.07 for JAFROC. This work demonstrates that for the task of identifying pulmonary nodules, the use of the iPad does not significantly change performance compared to an off-the-shelf LCD.

  6. The effects of high resistance-few repetitions and low resistance-high repetitions resistance training on climbing performance.

    PubMed

    Hermans, Espen; Andersen, Vidar; Saeterbakken, Atle Hole

    2017-05-01

    The aim of the study was to compare the effects of different strength training intensities on climbing performance, climbing-specific tests and a general strength test. Thirty lower grade and intermediate-level climbers participated in a 10-week training programme. The participants were randomized into three groups: high resistance-few repetitions training groups (HR-FR), low resistance-high repetitions training groups (LR-HR) and a control group (CON) which continued climbing/training as usual. Post-testing results demonstrated statistical tendencies for climbing performance improvements in the HR-FR and LR-HR (p = 0.088-0.090, effect size = 0.55-0.73), but no differences were observed between the groups (p = 0.950). For the climbing-specific tests, no differences were observed between the groups (p = 0.507-1.000), but the HR-FR and LR-HR improved their time in both Dead-hang (p = 0.004-0.026) and Bent-arm hang (p < 0.001-0.002). The HR-FR and LR-HR improved their 12RM strength in pull-down (p ≤ 0.001), but not the CON group (p = 0.250). No differences were observed in the CON group in any of the tests (p = 0.190-0.596) with the exception of improvement in Bent-arm Hang (p = 0.018). The training groups reduced their climbing sessions during the intervention compared to the CON group (p = 0.057-0.074). In conclusion, HR-FR and LR-HR training programmes demonstrated an 11% and 12% non-significant improvement in climbing performance despite a 50% reduction in climbing sessions, but improved the results in strength and climbing-specific tests. None of the training intensities was superior compared to the others.

  7. A hybrid electromagnetic shock absorber for active vehicle suspension systems

    NASA Astrophysics Data System (ADS)

    Ebrahimi, Babak; Bolandhemmat, Hamidreza; Behrad Khamesee, Mir; Golnaraghi, Farid

    2011-02-01

    The use of electromagnetic dampers (ED) in vehicle active suspension systems has drawn considerable attention in the past few years, attributed to the fact that active suspension systems have shown superior performance in improving ride comfort and road handling of terrain vehicles, compared with their passive and semi-active counterparts. Although demonstrating superb performance, active suspensions still have some shortcomings that must be overcome. They have high energy consumption, weight, and cost and are not fail-safe in case of a power breakdown. The novel hybrid ED, which is proposed in this paper, is a potential solution to the above-mentioned drawbacks of conventional active suspension systems. The proposed hybrid ED is designed to inherit the high-performance characteristics of an active ED with the reliability of a passive damper in a single package. The eddy current damping effect is utilised as a source of the passive damping. First, a prototype ED is designed and fabricated. The prototype ED is then utilised to experimentally establish the design requirements for a real-size active ED. This is accomplished by comparing its vibration isolation performance in a 1-DOF quarter-car test rig with that of a same-class semi-active damper. Then, after a real-size active ED is designed, the concept of hybrid damper is introduced to the damper design to address the drawbacks of the active ED. Finally, the finite-element method is used to accurately model and analyse the designed hybrid damper. It is demonstrated that by introducing the eddy current damping effect to the active part, a passive damping of approximately 1570 Ns/m is achieved. This amount of passive damping guarantees that the damper is fail-safe and reduces the power consumption more than 70%, compared with an active ED in an automotive active suspension system.

  8. Efficacy of antidepressive medication for depression in Parkinson disease: a network meta-analysis

    PubMed Central

    Zhuo, Chuanjun; Xue, Rong; Luo, Lanlan; Ji, Feng; Tian, Hongjun; Qu, Hongru; Lin, Xiaodong; Jiang, Ronghuan; Tao, Ran

    2017-01-01

    Abstract Background: Parkinson disease (PD) was considered as the 2nd most prevalent neurodegenerative disorder after Alzheimer disease, while depression is a prevailing nonmotor symptom of PD. Typically used antidepression medication includes tricyclic antidepressants (TCA), selective serotonin reuptake inhibitors (SSRI), serotonin and norepinephrine reuptake inhibitors (SNRI), monoamine-oxidase inhibitors (MAOI), and dopamine agonists (DA). Our study aimed at evaluating the efficacy of antidepressive medications for depression of PD. Methods: Web of Science, PubMed, Embase, and the Cochrane library were searched for related articles. Traditional meta-analysis and network meta-analysis (NMA) were performed with outcomes including depression score, UPDRS-II, UPDRS-III, and adverse effects. Surface under the cumulative ranking curve (SUCRA) was also performed to illustrate the rank probabilities of different medications on various outcomes. The consistency of direct and indirect evidence was also assessed by node-splitting method. Results: Results of traditional pairwise meta-analysis were performed. Concerning depression score, significant improvement was observed in AD, MAOI, SSRI, and SNRI compared with placebo. NMA was performed and more information could be obtained. DA was illustrated to be effective over placebo concerning UPDRS-III, MAOI, and SNRI. DA demonstrated a better prognosis in UPDRS-II scores compared with placebo and MAOI. However, DA and SSRI demonstrated a significant increase in adverse effects compared with placebo. The SUCRA value was calculated to evaluate the ranking probabilities of all medications on investigated outcomes, and the consistency between direct and indirect evidences was assessed by node-splitting method. Conclusion: SSRI had a satisfying efficacy for the depression of PD patients and could improve activities of daily living and motor function of patient but the adverse effects are unneglectable. SNRI are the safest medication with high efficacy for depression as well while other outcomes are relatively poor. PMID:28562526

  9. Performance Outcomes After Metacarpal Fractures in National Basketball Association Players.

    PubMed

    Guss, Michael S; Begly, John P; Ramme, Austin J; Hinds, Richard M; Karia, Raj J; Capo, John T

    2016-12-01

    Background: The aim was to determine whether players in the National Basketball Association (NBA) who sustain metacarpal fractures demonstrate decreased performance upon return to competition when compared with their performance before injury and that of their control-matched peers. Methods: Data for 32 NBA players with metacarpal fractures incurred over 11 seasons (2002-2003 to 2012-2013) were obtained from injury reports, press releases, and player profiles (www.nba.com and www.basketballreference.com). Player age, body mass index (BMI), position, shooting hand, number of years in the league, and treatment (surgical vs nonsurgical) were recorded. Individual season statistics for the 2 seasons immediately prior to injury and the 2 seasons after injury, including player efficiency rating (PER), were obtained. Thirty-two controls matched by player position, age, and performance statistics were identified. A performance comparison of the cohorts was performed. Results: Mean age at the time of injury was 27 years with an average player BMI of 24. Players had a mean 5.6 seasons of NBA experience prior to injury. There was no significant change in PER when preinjury and postinjury performances were compared. Neither injury to their shooting hand nor operative management of the fracture led to a decrease in performance during the 2 seasons after injury. When compared with matched controls, no significant decline in performance in PER the first season and second season after injury was found. Conclusion: NBA players sustaining metacarpal fractures can reasonably expect to return to their preinjury performance levels following appropriate treatment.

  10. Performance Outcomes After Metacarpal Fractures in National Basketball Association Players

    PubMed Central

    Guss, Michael S.; Begly, John P.; Ramme, Austin J.; Hinds, Richard M.; Karia, Raj J.; Capo, John T.

    2016-01-01

    Background: The aim was to determine whether players in the National Basketball Association (NBA) who sustain metacarpal fractures demonstrate decreased performance upon return to competition when compared with their performance before injury and that of their control-matched peers. Methods: Data for 32 NBA players with metacarpal fractures incurred over 11 seasons (2002-2003 to 2012-2013) were obtained from injury reports, press releases, and player profiles (www.nba.com and www.basketballreference.com). Player age, body mass index (BMI), position, shooting hand, number of years in the league, and treatment (surgical vs nonsurgical) were recorded. Individual season statistics for the 2 seasons immediately prior to injury and the 2 seasons after injury, including player efficiency rating (PER), were obtained. Thirty-two controls matched by player position, age, and performance statistics were identified. A performance comparison of the cohorts was performed. Results: Mean age at the time of injury was 27 years with an average player BMI of 24. Players had a mean 5.6 seasons of NBA experience prior to injury. There was no significant change in PER when preinjury and postinjury performances were compared. Neither injury to their shooting hand nor operative management of the fracture led to a decrease in performance during the 2 seasons after injury. When compared with matched controls, no significant decline in performance in PER the first season and second season after injury was found. Conclusion: NBA players sustaining metacarpal fractures can reasonably expect to return to their preinjury performance levels following appropriate treatment. PMID:28149209

  11. Relative health performance in BRICS over the past 20 years: the winners and losers

    PubMed Central

    Petrie, Dennis

    2014-01-01

    Abstract Objective To determine whether the health performance of Brazil, the Russian Federation, India, China and South Africa – the countries known as BRICS – has kept in step with their economic development. Methods Reductions in age- and sex-specific mortality seen in each BRICS country between 1990 and 2011 were measured. These results were compared with those of the best-performing countries in the world and the best-performing countries with similar income levels. We estimated each country’s progress in reducing mortality and compared changes in that country’s mortality rates against other countries with similar mean incomes to examine changes in avoidable mortality. Findings The relative health performance of the five study countries differed markedly over the study period. Brazil demonstrated fairly even improvement in relative health performance across the different age and sex subgroups that we assessed. India’s improvement was more modest and more varied across the subgroups. South Africa and the Russian Federation exhibited large declines in health performance as well as large sex-specific inequalities in health. Although China’s levels of avoidable mortality decreased in absolute terms, the level of improvement appeared low in the context of China’s economic growth. Conclusion When evaluating a country’s health performance in terms of avoidable mortality, it is useful to compare that performance against the performance of other countries. Such comparison allows any country-specific improvements to be distinguished from general global improvements. PMID:24940013

  12. Clinical Named Entity Recognition Using Deep Learning Models.

    PubMed

    Wu, Yonghui; Jiang, Min; Xu, Jun; Zhi, Degui; Xu, Hua

    2017-01-01

    Clinical Named Entity Recognition (NER) is a critical natural language processing (NLP) task to extract important concepts (named entities) from clinical narratives. Researchers have extensively investigated machine learning models for clinical NER. Recently, there have been increasing efforts to apply deep learning models to improve the performance of current clinical NER systems. This study examined two popular deep learning architectures, the Convolutional Neural Network (CNN) and the Recurrent Neural Network (RNN), to extract concepts from clinical texts. We compared the two deep neural network architectures with three baseline Conditional Random Fields (CRFs) models and two state-of-the-art clinical NER systems using the i2b2 2010 clinical concept extraction corpus. The evaluation results showed that the RNN model trained with the word embeddings achieved a new state-of-the- art performance (a strict F1 score of 85.94%) for the defined clinical NER task, outperforming the best-reported system that used both manually defined and unsupervised learning features. This study demonstrates the advantage of using deep neural network architectures for clinical concept extraction, including distributed feature representation, automatic feature learning, and long-term dependencies capture. This is one of the first studies to compare the two widely used deep learning models and demonstrate the superior performance of the RNN model for clinical NER.

  13. Glide performance and aerodynamics of non-equilibrium glides in northern flying squirrels (Glaucomys sabrinus)

    PubMed Central

    Bahlman, Joseph W.; Swartz, Sharon M.; Riskin, Daniel K.; Breuer, Kenneth S.

    2013-01-01

    Gliding is an efficient form of travel found in every major group of terrestrial vertebrates. Gliding is often modelled in equilibrium, where aerodynamic forces exactly balance body weight resulting in constant velocity. Although the equilibrium model is relevant for long-distance gliding, such as soaring by birds, it may not be realistic for shorter distances between trees. To understand the aerodynamics of inter-tree gliding, we used direct observation and mathematical modelling. We used videography (60–125 fps) to track and reconstruct the three-dimensional trajectories of northern flying squirrels (Glaucomys sabrinus) in nature. From their trajectories, we calculated velocities, aerodynamic forces and force coefficients. We determined that flying squirrels do not glide at equilibrium, and instead demonstrate continuously changing velocities, forces and force coefficients, and generate more lift than needed to balance body weight. We compared observed glide performance with mathematical simulations that use constant force coefficients, a characteristic of equilibrium glides. Simulations with varying force coefficients, such as those of live squirrels, demonstrated better whole-glide performance compared with the theoretical equilibrium state. Using results from both the observed glides and the simulation, we describe the mechanics and execution of inter-tree glides, and then discuss how gliding behaviour may relate to the evolution of flapping flight. PMID:23256188

  14. Examining the interaction between cognitive control and reward sensitivity in substance use dependence.

    PubMed

    Charles-Walsh, Kathleen; Upton, Daniel J; Hester, Robert

    2016-09-01

    Drug dependence is characterized by altered reward processing and poor cognitive control, expressed as a preference for immediate rewards and impaired inhibitory control, respectively. To examine the interaction between reward processing (via the presence or absence of reward) and mechanisms of inhibitory control in drug dependence, the current study used the Monetary Incentive Control Task (MICT) to examine whether a group of opiate dependent persons demonstrated greater difficulty exerting control over immediate rewards compared to neutral stimuli. The MICT is a Go/Stop paradigm that examines inhibitory control over immediate rewards. Performance of 32 opiate dependent individuals was compared to 29 healthy controls. Opiate users demonstrated poorer inhibitory performance than controls, irrespective of cues signaling immediate reward. Whereas control participants' responses were modulated by probability cues, the opiate group did not show a capacity to up-regulate their cognitive control performance. The present results suggest a general decrease in cognitive control in opiate dependence, accompanied by a reduced ability to optimally modulate behavior in accordance with external cues. Opiate users and controls did not differ in the interaction between cognitive control and reward. The study highlights important issues for future research to consider when further examining this interaction in drug dependence. Crown Copyright © 2016. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Glide performance and aerodynamics of non-equilibrium glides in northern flying squirrels (Glaucomys sabrinus).

    PubMed

    Bahlman, Joseph W; Swartz, Sharon M; Riskin, Daniel K; Breuer, Kenneth S

    2013-03-06

    Gliding is an efficient form of travel found in every major group of terrestrial vertebrates. Gliding is often modelled in equilibrium, where aerodynamic forces exactly balance body weight resulting in constant velocity. Although the equilibrium model is relevant for long-distance gliding, such as soaring by birds, it may not be realistic for shorter distances between trees. To understand the aerodynamics of inter-tree gliding, we used direct observation and mathematical modelling. We used videography (60-125 fps) to track and reconstruct the three-dimensional trajectories of northern flying squirrels (Glaucomys sabrinus) in nature. From their trajectories, we calculated velocities, aerodynamic forces and force coefficients. We determined that flying squirrels do not glide at equilibrium, and instead demonstrate continuously changing velocities, forces and force coefficients, and generate more lift than needed to balance body weight. We compared observed glide performance with mathematical simulations that use constant force coefficients, a characteristic of equilibrium glides. Simulations with varying force coefficients, such as those of live squirrels, demonstrated better whole-glide performance compared with the theoretical equilibrium state. Using results from both the observed glides and the simulation, we describe the mechanics and execution of inter-tree glides, and then discuss how gliding behaviour may relate to the evolution of flapping flight.

  16. Examining the Effect of Age on Visual-Vestibular Self-Motion Perception Using a Driving Paradigm.

    PubMed

    Ramkhalawansingh, Robert; Keshavarz, Behrang; Haycock, Bruce; Shahab, Saba; Campos, Jennifer L

    2017-05-01

    Previous psychophysical research has examined how younger adults and non-human primates integrate visual and vestibular cues to perceive self-motion. However, there is much to be learned about how multisensory self-motion perception changes with age, and how these changes affect performance on everyday tasks involving self-motion. Evidence suggests that older adults display heightened multisensory integration compared with younger adults; however, few previous studies have examined this for visual-vestibular integration. To explore age differences in the way that visual and vestibular cues contribute to self-motion perception, we had younger and older participants complete a basic driving task containing visual and vestibular cues. We compared their performance against a previously established control group that experienced visual cues alone. Performance measures included speed, speed variability, and lateral position. Vestibular inputs resulted in more precise speed control among older adults, but not younger adults, when traversing curves. Older adults demonstrated more variability in lateral position when vestibular inputs were available versus when they were absent. These observations align with previous evidence of age-related differences in multisensory integration and demonstrate that they may extend to visual-vestibular integration. These findings may have implications for vehicle and simulator design when considering older users.

  17. Clinical Named Entity Recognition Using Deep Learning Models

    PubMed Central

    Wu, Yonghui; Jiang, Min; Xu, Jun; Zhi, Degui; Xu, Hua

    2017-01-01

    Clinical Named Entity Recognition (NER) is a critical natural language processing (NLP) task to extract important concepts (named entities) from clinical narratives. Researchers have extensively investigated machine learning models for clinical NER. Recently, there have been increasing efforts to apply deep learning models to improve the performance of current clinical NER systems. This study examined two popular deep learning architectures, the Convolutional Neural Network (CNN) and the Recurrent Neural Network (RNN), to extract concepts from clinical texts. We compared the two deep neural network architectures with three baseline Conditional Random Fields (CRFs) models and two state-of-the-art clinical NER systems using the i2b2 2010 clinical concept extraction corpus. The evaluation results showed that the RNN model trained with the word embeddings achieved a new state-of-the- art performance (a strict F1 score of 85.94%) for the defined clinical NER task, outperforming the best-reported system that used both manually defined and unsupervised learning features. This study demonstrates the advantage of using deep neural network architectures for clinical concept extraction, including distributed feature representation, automatic feature learning, and long-term dependencies capture. This is one of the first studies to compare the two widely used deep learning models and demonstrate the superior performance of the RNN model for clinical NER. PMID:29854252

  18. Performance of Renormalization Group Algebraic Turbulence Model on Boundary Layer Transition Simulation

    NASA Technical Reports Server (NTRS)

    Ahn, Kyung H.

    1994-01-01

    The RNG-based algebraic turbulence model, with a new method of solving the cubic equation and applying new length scales, is introduced. An analysis is made of the RNG length scale which was previously reported and the resulting eddy viscosity is compared with those from other algebraic turbulence models. Subsequently, a new length scale is introduced which actually uses the two previous RNG length scales in a systematic way to improve the model performance. The performance of the present RNG model is demonstrated by simulating the boundary layer flow over a flat plate and the flow over an airfoil.

  19. Three-dimensional non-destructive optical evaluation of laser-processing performance using optical coherence tomography.

    PubMed

    Kim, Youngseop; Choi, Eun Seo; Kwak, Wooseop; Shin, Yongjin; Jung, Woonggyu; Ahn, Yeh-Chan; Chen, Zhongping

    2008-06-01

    We demonstrate the use of optical coherence tomography (OCT) as a non-destructive diagnostic tool for evaluating laser-processing performance by imaging the features of a pit and a rim. A pit formed on a material at different laser-processing conditions is imaged using both a conventional scanning electron microscope (SEM) and OCT. Then using corresponding images, the geometrical characteristics of the pit are analyzed and compared. From the results, we could verify the feasibility and the potential of the application of OCT to the monitoring of the laser-processing performance.

  20. Cartridge output testing - Methods to overcome closed-bomb shortcomings

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J.; Schimmel, Morry L.

    1991-01-01

    Although the closed-bomb test has achieved virtually universal acceptance for measuring the output performance of pyrotechnic cartridges, there are serious shortcomings in its ability to quantify the performance of cartridges used as energy sources for pyrotechnic-activated mechanical devices. This paper presents several examples of cartridges (including the NASA Standard Initiator NSI) that successfully met closed-bomb performance requirements, but resulted in functional failures in mechanisms. To resolve these failures, test methods were developed to demonstrate a functional margin, based on comparing energy required to accomplish the function to energy deliverable by the cartridge.

  1. Three-dimensional non-destructive optical evaluation of laser-processing performance using optical coherence tomography

    PubMed Central

    Kim, Youngseop; Choi, Eun Seo; Kwak, Wooseop; Shin, Yongjin; Jung, Woonggyu; Ahn, Yeh-Chan; Chen, Zhongping

    2014-01-01

    We demonstrate the use of optical coherence tomography (OCT) as a non-destructive diagnostic tool for evaluating laser-processing performance by imaging the features of a pit and a rim. A pit formed on a material at different laser-processing conditions is imaged using both a conventional scanning electron microscope (SEM) and OCT. Then using corresponding images, the geometrical characteristics of the pit are analyzed and compared. From the results, we could verify the feasibility and the potential of the application of OCT to the monitoring of the laser-processing performance. PMID:24932051

  2. Model-Free CUSUM Methods for Person Fit

    ERIC Educational Resources Information Center

    Armstrong, Ronald D.; Shi, Min

    2009-01-01

    This article demonstrates the use of a new class of model-free cumulative sum (CUSUM) statistics to detect person fit given the responses to a linear test. The fundamental statistic being accumulated is the likelihood ratio of two probabilities. The detection performance of this CUSUM scheme is compared to other model-free person-fit statistics…

  3. An Evaluation of the Clinical Performance of Newly Qualified Nurses: A Competency Based Assessment.

    ERIC Educational Resources Information Center

    O'Connor, S. E.; Pearce, J.; Smith, R. L.; Voegeli, D.; Walton, P.

    2001-01-01

    Senior nurses' (n=139) expectations of 36 beginning nurses were compared with the beginners' competence ratings by their clinical preceptors. Senior nurses' expectations were lower than the actual competence demonstrated by the graduates, suggesting that assessment instruments should not be derived solely from supervisor expectations. (SK)

  4. Planes, Politics and Oral Proficiency: Testing International Air Traffic Controllers

    ERIC Educational Resources Information Center

    Moder, Carol Lynn; Halleck, Gene B.

    2009-01-01

    This study investigates the variation in oral proficiency demonstrated by 14 Air Traffic Controllers across two types of testing tasks: work-related radio telephony-based tasks and non-specific English tasks on aviation topics. Their performance was compared statistically in terms of level ratings on the International Civil Aviation Organization…

  5. No Sex Differences in Spatial Location Memory for Abstract Designs

    ERIC Educational Resources Information Center

    Rahman, Qazi; Bakare, Monsurat; Serinsu, Ceydan

    2011-01-01

    Previous research has demonstrated a female advantage, albeit imperfectly, on tests of object location memory where object identity information is readily available. However, spatial and visual elements are often confounded in the experimental tasks used. Here spatial and visual memory performance was compared in 30 men and 30 women by presenting…

  6. A Computational Study of the Energy Dissipation Through an Acrylic Target Impacted by Various Size FSP

    DTIC Science & Technology

    2009-06-01

    data, and then returns an array that describes the line. This function, when compared to the LOGEST statistical function of the Microsoft Excel, which...threats continues to grow, the ability to predict materials performances using advanced modeling tools increases. The current paper has demonstrated

  7. Online Learning and Teacher Education: Knowledge Acquisition, Application Skills, and Reported Confidence

    ERIC Educational Resources Information Center

    IRIS Center, 2014

    2014-01-01

    This report presents two studies that demonstrate superior performance of college students after use of free, online instructional Modules, produced by the IRIS Center. When compared to traditional teacher education methods, IRIS Modules yield better outcomes in terms of knowledge acquisition, application skills, and confidence in the use of…

  8. Fault tree models for fault tolerant hypercube multiprocessors

    NASA Technical Reports Server (NTRS)

    Boyd, Mark A.; Tuazon, Jezus O.

    1991-01-01

    Three candidate fault tolerant hypercube architectures are modeled, their reliability analyses are compared, and the resulting implications of these methods of incorporating fault tolerance into hypercube multiprocessors are discussed. In the course of performing the reliability analyses, the use of HARP and fault trees in modeling sequence dependent system behaviors is demonstrated.

  9. Demonstration tests of infrared peeling system with electrical emitters for tomatoes

    USDA-ARS?s Scientific Manuscript database

    Infrared (IR) dry-peeling is an emerging technology that could avoid the drawbacks of steam and lye peeling of tomatoes. The objectives of this research was to evaluate the performance of an IR peeling system at two tomato processing plants located in California and to compare product quality, peela...

  10. Progress Towards a Cartesian Cut-Cell Method for Viscous Compressible Flow

    NASA Technical Reports Server (NTRS)

    Berger, Marsha; Aftosmis, Michael J.

    2011-01-01

    The proposed paper reports advances in developing a method for high Reynolds number compressible viscous flow simulations using a Cartesian cut-cell method with embedded boundaries. This preliminary work focuses on accuracy of the discretization near solid wall boundaries. A model problem is used to investigate the accuracy of various difference stencils for second derivatives and to guide development of the discretization of the viscous terms in the Navier-Stokes equations. Near walls, quadratic reconstruction in the wall-normal direction is used to mitigate mesh irregularity and yields smooth skin friction distributions along the body. Multigrid performance is demonstrated using second-order coarse grid operators combined with second-order restriction and prolongation operators. Preliminary verification and validation for the method is demonstrated using flat-plate and airfoil examples at compressible Mach numbers. Simulations of flow on laminar and turbulent flat plates show skin friction and velocity profiles compared with those from boundary-layer theory. Airfoil simulations are performed at laminar and turbulent Reynolds numbers with results compared to both other simulations and experimental data

  11. Hybrid dose calculation: a dose calculation algorithm for microbeam radiation therapy

    NASA Astrophysics Data System (ADS)

    Donzelli, Mattia; Bräuer-Krisch, Elke; Oelfke, Uwe; Wilkens, Jan J.; Bartzsch, Stefan

    2018-02-01

    Microbeam radiation therapy (MRT) is still a preclinical approach in radiation oncology that uses planar micrometre wide beamlets with extremely high peak doses, separated by a few hundred micrometre wide low dose regions. Abundant preclinical evidence demonstrates that MRT spares normal tissue more effectively than conventional radiation therapy, at equivalent tumour control. In order to launch first clinical trials, accurate and efficient dose calculation methods are an inevitable prerequisite. In this work a hybrid dose calculation approach is presented that is based on a combination of Monte Carlo and kernel based dose calculation. In various examples the performance of the algorithm is compared to purely Monte Carlo and purely kernel based dose calculations. The accuracy of the developed algorithm is comparable to conventional pure Monte Carlo calculations. In particular for inhomogeneous materials the hybrid dose calculation algorithm out-performs purely convolution based dose calculation approaches. It is demonstrated that the hybrid algorithm can efficiently calculate even complicated pencil beam and cross firing beam geometries. The required calculation times are substantially lower than for pure Monte Carlo calculations.

  12. Compression in wearable sensor nodes: impacts of node topology.

    PubMed

    Imtiaz, Syed Anas; Casson, Alexander J; Rodriguez-Villegas, Esther

    2014-04-01

    Wearable sensor nodes monitoring the human body must operate autonomously for very long periods of time. Online and low-power data compression embedded within the sensor node is therefore essential to minimize data storage/transmission overheads. This paper presents a low-power MSP430 compressive sensing implementation for providing such compression, focusing particularly on the impact of the sensor node architecture on the compression performance. Compression power performance is compared for four different sensor nodes incorporating different strategies for wireless transmission/on-sensor-node local storage of data. The results demonstrate that the compressive sensing used must be designed differently depending on the underlying node topology, and that the compression strategy should not be guided only by signal processing considerations. We also provide a practical overview of state-of-the-art sensor node topologies. Wireless transmission of data is often preferred as it offers increased flexibility during use, but in general at the cost of increased power consumption. We demonstrate that wireless sensor nodes can highly benefit from the use of compressive sensing and now can achieve power consumptions comparable to, or better than, the use of local memory.

  13. Implementation of metal-friendly EAM/FS-type semi-empirical potentials in HOOMD-blue: A GPU-accelerated molecular dynamics software

    DOE PAGES

    Yang, Lin; Zhang, Feng; Wang, Cai-Zhuang; ...

    2018-01-12

    We present an implementation of EAM and FS interatomic potentials, which are widely used in simulating metallic systems, in HOOMD-blue, a software designed to perform classical molecular dynamics simulations using GPU accelerations. We first discuss the details of our implementation and then report extensive benchmark tests. We demonstrate that single-precision floating point operations efficiently implemented on GPUs can produce sufficient accuracy when compared against double-precision codes, as demonstrated in test simulations of calculations of the glass-transition temperature of Cu 64.5Zr 35.5, and pair correlation function of liquid Ni 3Al. Our code scales well with the size of the simulating systemmore » on NVIDIA Tesla M40 and P100 GPUs. Compared with another popular software LAMMPS running on 32 cores of AMD Opteron 6220 processors, the GPU/CPU performance ratio can reach as high as 4.6. In conclusion, the source code can be accessed through the HOOMD-blue web page for free by any interested user.« less

  14. Implementation of metal-friendly EAM/FS-type semi-empirical potentials in HOOMD-blue: A GPU-accelerated molecular dynamics software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Lin; Zhang, Feng; Wang, Cai-Zhuang

    We present an implementation of EAM and FS interatomic potentials, which are widely used in simulating metallic systems, in HOOMD-blue, a software designed to perform classical molecular dynamics simulations using GPU accelerations. We first discuss the details of our implementation and then report extensive benchmark tests. We demonstrate that single-precision floating point operations efficiently implemented on GPUs can produce sufficient accuracy when compared against double-precision codes, as demonstrated in test simulations of calculations of the glass-transition temperature of Cu 64.5Zr 35.5, and pair correlation function of liquid Ni 3Al. Our code scales well with the size of the simulating systemmore » on NVIDIA Tesla M40 and P100 GPUs. Compared with another popular software LAMMPS running on 32 cores of AMD Opteron 6220 processors, the GPU/CPU performance ratio can reach as high as 4.6. In conclusion, the source code can be accessed through the HOOMD-blue web page for free by any interested user.« less

  15. Carbohydrate and exercise performance: the role of multiple transportable carbohydrates.

    PubMed

    Jeukendrup, Asker E

    2010-07-01

    Carbohydrate feeding has been shown to be ergogenic, but recently substantial advances have been made in optimizing the guidelines for carbohydrate intake during prolonged exercise. It was found that limitations to carbohydrate oxidation were in the absorptive process most likely because of a saturation of carbohydrate transporters. By using a combination of carbohydrates that use different intestinal transporters for absorption it was shown that carbohydrate delivery and oxidation could be increased. Studies demonstrated increases in exogenous carbohydrate oxidation rates of up to 65% of glucose: fructose compared with glucose only. Exogenous carbohydrate oxidation rates reach values of 1.75 g/min whereas previously it was thought that 1 g/min was the absolute maximum. The increased carbohydrate oxidation with multiple transportable carbohydrates was accompanied by increased fluid delivery and improved oxidation efficiency, and thus the likelihood of gastrointestinal distress may be diminished. Studies also demonstrated reduced fatigue and improved exercise performance with multiple transportable carbohydrates compared with a single carbohydrate. Multiple transportable carbohydrates, ingested at high rates, can be beneficial during endurance sports in which the duration of exercise is 3 h or more.

  16. Performance analysis of SiGe double-gate N-MOSFET

    NASA Astrophysics Data System (ADS)

    Singh, A.; Kapoor, D.; Sharma, R.

    2017-04-01

    The major purpose of this paper is to find an alternative configuration that not only minimizes the limitations of single-gate (SG) MOSFETs but also provides the better replacement for future technology. In this paper, the electrical characteristics of SiGe double-gate N-MOSFET are demonstrated and compared with electrical characteristics of Si double-gate N-MOSFET. Furthermore, in this paper the electrical characteristics of Si double-gate N-MOSFET are demonstrated and compared with electrical characteristics of Si single-gate N-MOSFET. The simulations are carried out for the device at different operational voltages using Cogenda Visual TCAD tool. Moreover, we have designed its structure and studied both {I}{{d}}{-}{V}{{g}} characteristics for different voltages namely 0.05, 0.1, 0.5, 0.8, 1 and 1.5 V and {I}{{d}}{-}{V}{{d}} characteristics for different voltages namely 0.1, 0.5, 1 and 1.5 V at work functions 4.5, 4.6 and 4.8 eV for this structure. The performance parameters investigated in this paper are threshold voltage, DIBL, subthreshold slope, GIDL, volume inversion and MMCR.

  17. The levels of processing effect under nitrogen narcosis.

    PubMed

    Kneller, Wendy; Hobbs, Malcolm

    2013-01-01

    Previous research has consistently demonstrated that inert gas (nitrogen) narcosis affects free recall but not recognition memory in the depth range of 30 to 50 meters of sea water (msw), possibly as a result of narcosis preventing processing when learned material is encoded. The aim of the current research was to test this hypothesis by applying a levels of processing approach to the measurement of free recall under narcosis. Experiment 1 investigated the effect of depth (0-2 msw vs. 37-39 msw) and level of processing (shallow vs. deep) on free recall memory performance in 67 divers. When age was included as a covariate, recall was significantly worse in deep water (i.e., under narcosis), compared to shallow water, and was significantly higher in the deep processing compared to shallow processing conditions in both depth conditions. Experiment 2 demonstrated that this effect was not simply due to the different underwater environments used for the depth conditions in Experiment 1. It was concluded memory performance can be altered by processing under narcosis and supports the contention that narcosis affects the encoding stage of memory as opposed to self-guided search (retrieval).

  18. The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease.

    PubMed

    Thomas, Joseph L; Ridner, Michael; Cole, Jason H; Chambers, Jeffrey W; Bokhari, Sabahat; Yannopoulos, Demetris; Kern, Morton; Wilson, Robert F; Budoff, Matthew J

    2018-06-23

    The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.

  19. Propeller flow visualization techniques

    NASA Technical Reports Server (NTRS)

    Stefko, G. L.; Paulovich, F. J.; Greissing, J. P.; Walker, E. D.

    1982-01-01

    Propeller flow visualization techniques were tested. The actual operating blade shape as it determines the actual propeller performance and noise was established. The ability to photographically determine the advanced propeller blade tip deflections, local flow field conditions, and gain insight into aeroelastic instability is demonstrated. The analytical prediction methods which are being developed can be compared with experimental data. These comparisons contribute to the verification of these improved methods and give improved capability for designing future advanced propellers with enhanced performance and noise characteristics.

  20. Children of psychotic mothers. An evaluation of 1-year-olds on a test of object permanence.

    PubMed

    Gamer, E; Gallant, D; Grunebaum, H

    1976-03-01

    Fifteen 1-year-old infants at high risk for later psychopathologic behavior were tested on the Piaget Object Scale. Their performance was compared to that of a matched group of controls at low risk. Results indicate a trend in the high-risk group toward lowered object scale performance. Affective styles were found to vary between the groups. The high-risk infants, particularly those with low scores on the object scale, demonstrated more intense anxiety.

  1. Implementation and Performance Issues in Collaborative Optimization

    NASA Technical Reports Server (NTRS)

    Braun, Robert; Gage, Peter; Kroo, Ilan; Sobieski, Ian

    1996-01-01

    Collaborative optimization is a multidisciplinary design architecture that is well-suited to large-scale multidisciplinary optimization problems. This paper compares this approach with other architectures, examines the details of the formulation, and some aspects of its performance. A particular version of the architecture is proposed to better accommodate the occurrence of multiple feasible regions. The use of system level inequality constraints is shown to increase the convergence rate. A series of simple test problems, demonstrated to challenge related optimization architectures, is successfully solved with collaborative optimization.

  2. The OpenMP Implementation of NAS Parallel Benchmarks and its Performance

    NASA Technical Reports Server (NTRS)

    Jin, Hao-Qiang; Frumkin, Michael; Yan, Jerry

    1999-01-01

    As the new ccNUMA architecture became popular in recent years, parallel programming with compiler directives on these machines has evolved to accommodate new needs. In this study, we examine the effectiveness of OpenMP directives for parallelizing the NAS Parallel Benchmarks. Implementation details will be discussed and performance will be compared with the MPI implementation. We have demonstrated that OpenMP can achieve very good results for parallelization on a shared memory system, but effective use of memory and cache is very important.

  3. Quo vadis: Hydrologic inverse analyses using high-performance computing and a D-Wave quantum annealer

    NASA Astrophysics Data System (ADS)

    O'Malley, D.; Vesselinov, V. V.

    2017-12-01

    Classical microprocessors have had a dramatic impact on hydrology for decades, due largely to the exponential growth in computing power predicted by Moore's law. However, this growth is not expected to continue indefinitely and has already begun to slow. Quantum computing is an emerging alternative to classical microprocessors. Here, we demonstrated cutting edge inverse model analyses utilizing some of the best available resources in both worlds: high-performance classical computing and a D-Wave quantum annealer. The classical high-performance computing resources are utilized to build an advanced numerical model that assimilates data from O(10^5) observations, including water levels, drawdowns, and contaminant concentrations. The developed model accurately reproduces the hydrologic conditions at a Los Alamos National Laboratory contamination site, and can be leveraged to inform decision-making about site remediation. We demonstrate the use of a D-Wave 2X quantum annealer to solve hydrologic inverse problems. This work can be seen as an early step in quantum-computational hydrology. We compare and contrast our results with an early inverse approach in classical-computational hydrology that is comparable to the approach we use with quantum annealing. Our results show that quantum annealing can be useful for identifying regions of high and low permeability within an aquifer. While the problems we consider are small-scale compared to the problems that can be solved with modern classical computers, they are large compared to the problems that could be solved with early classical CPUs. Further, the binary nature of the high/low permeability problem makes it well-suited to quantum annealing, but challenging for classical computers.

  4. A fourth-order Cartesian grid embeddedboundary method for Poisson’s equation

    DOE PAGES

    Devendran, Dharshi; Graves, Daniel; Johansen, Hans; ...

    2017-05-08

    In this paper, we present a fourth-order algorithm to solve Poisson's equation in two and three dimensions. We use a Cartesian grid, embedded boundary method to resolve complex boundaries. We use a weighted least squares algorithm to solve for our stencils. We use convergence tests to demonstrate accuracy and we show the eigenvalues of the operator to demonstrate stability. We compare accuracy and performance with an established second-order algorithm. We also discuss in depth strategies for retaining higher-order accuracy in the presence of nonsmooth geometries.

  5. Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, A.; Lubliner, M.; Howard, L.

    2013-10-01

    This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilation strategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7.

  6. A fourth-order Cartesian grid embeddedboundary method for Poisson’s equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devendran, Dharshi; Graves, Daniel; Johansen, Hans

    In this paper, we present a fourth-order algorithm to solve Poisson's equation in two and three dimensions. We use a Cartesian grid, embedded boundary method to resolve complex boundaries. We use a weighted least squares algorithm to solve for our stencils. We use convergence tests to demonstrate accuracy and we show the eigenvalues of the operator to demonstrate stability. We compare accuracy and performance with an established second-order algorithm. We also discuss in depth strategies for retaining higher-order accuracy in the presence of nonsmooth geometries.

  7. Modeling daily discharge responses of a large karstic aquifer using soft computing methods: Artificial neural network and neuro-fuzzy

    NASA Astrophysics Data System (ADS)

    Kurtulus, Bedri; Razack, Moumtaz

    2010-02-01

    SummaryThis paper compares two methods for modeling karst aquifers, which are heterogeneous, highly non-linear, and hierarchical systems. There is a clear need to model these systems given the crucial role they play in water supply in many countries. In recent years, the main components of soft computing (fuzzy logic (FL), and Artificial Neural Networks, (ANNs)) have come to prevail in the modeling of complex non-linear systems in different scientific and technologic disciplines. In this study, Artificial Neural Networks and Adaptive Neuro-Fuzzy Interface System (ANFIS) methods were used for the prediction of daily discharge of karstic aquifers and their capability was compared. The approach was applied to 7 years of daily data of La Rochefoucauld karst system in south-western France. In order to predict the karst daily discharges, single-input (rainfall, piezometric level) vs. multiple-input (rainfall and piezometric level) series were used. In addition to these inputs, all models used measured or simulated discharges from the previous days with a specified delay. The models were designed in a Matlab™ environment. An automatic procedure was used to select the best calibrated models. Daily discharge predictions were then performed using the calibrated models. Comparing predicted and observed hydrographs indicates that both models (ANN and ANFIS) provide close predictions of the karst daily discharges. The summary statistics of both series (observed and predicted daily discharges) are comparable. The performance of both models is improved when the number of inputs is increased from one to two. The root mean square error between the observed and predicted series reaches a minimum for two-input models. However, the ANFIS model demonstrates a better performance than the ANN model to predict peak flow. The ANFIS approach demonstrates a better generalization capability and slightly higher performance than the ANN, especially for peak discharges.

  8. Velocity & displacement-dependent damper: A novel passive shock absorber inspired by the semi-active control

    NASA Astrophysics Data System (ADS)

    Nie, Shida; Zhuang, Ye; Wang, Yong; Guo, Konghui

    2018-01-01

    The performance of velocity & displacement-dependent damper (VDD), inspired by the semi-active control, is analyzed. The main differences among passive, displacement-dependent and semi-active dampers are compared on their damping properties. Valve assemblies of VDD are modelled to get an insight into its working principle. The mechanical structure composed by four valve assemblies helps to enable VDD to approach the performance by those semi-active control dampers. The valve structure parameters are determined by the suggested two-step process. Hydraulic model of the damper is built with AMEsim. Simulation result of F-V curves, which is similar to those of semi-active control damper, demonstrates that VDD could achieve the similar performance of semi-active control damper. The performance of a quarter vehicle model employing VDD is analyzed and compared with semi-active suspension. Simulation results show that VDD could perform as good as a semi-active control damper. In addition, no add-on hardware or energy consumption is needed for VDD to achieve the remarkable performance.

  9. The impact of culture and education on non-verbal neuropsychological measurements: a critical review.

    PubMed

    Rosselli, Mónica; Ardila, Alfredo

    2003-08-01

    Clinical neuropsychology has frequently considered visuospatial and non-verbal tests to be culturally and educationally fair or at least fairer than verbal tests. This paper reviews the cross-cultural differences in performance on visuoperceptual and visuoconstructional ability tasks and analyzes the impact of education and culture on non-verbal neuropsychological measurements. This paper compares: (1) non-verbal test performance among groups with different educational levels, and the same cultural background (inter-education intra-culture comparison); (2) the test performance among groups with the same educational level and different cultural backgrounds (intra-education inter-culture comparisons). Several studies have demonstrated a strong association between educational level and performance on common non-verbal neuropsychological tests. When neuropsychological test performance in different cultural groups is compared, significant differences are evident. Performance on non-verbal tests such as copying figures, drawing maps or listening to tones can be significantly influenced by the individual's culture. Arguments against the use of some current neuropsychological non-verbal instruments, procedures, and norms in the assessment of diverse educational and cultural groups are discussed and possible solutions to this problem are presented.

  10. Test of Hydrogen-Oxygen PEM Fuel Cell Stack at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Bents, David J.; Scullin, Vincent J.; Chang, Bei-Jiann; Johnson, Donald W.; Garcia, Christopher P.; Jakupca, Ian J.

    2003-01-01

    This paper describes performance characterization tests of a 64 cell hydrogen oxygen PEM fuel cell stack at NASA Glenn Research Center in February 2003. The tests were part of NASA's ongoing effort to develop a regenerative fuel cell for aerospace energy storage applications. The purpose of the tests was to verify capability of this stack to operate within a regenerative fuel cell, and to compare performance with earlier test results recorded by the stack developer. Test results obtained include polarization performance of the stack at 50 and 100 psig system pressure, and a steady state endurance run at 100 psig. A maximum power output of 4.8 kWe was observed during polarization runs, and the stack sustained a steady power output of 4.0 kWe during the endurance run. The performance data obtained from these tests compare reasonably close to the stack developer's results although some additional spread between best to worst performing cell voltages was observed. Throughout the tests, the stack demonstrated the consistent performance and repeatable behavior required for regenerative fuel cell operation.

  11. Identify and Quantify the Mechanistic Sources of Sensor Performance Variation Between Individual Sensors SN1 and SN2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diaz, Aaron A.; Baldwin, David L.; Cinson, Anthony D.

    2014-08-06

    This Technical Letter Report satisfies the M3AR-14PN2301022 milestone, and is focused on identifying and quantifying the mechanistic sources of sensor performance variation between individual 22-element, linear phased-array sensor prototypes, SN1 and SN2. This effort constitutes an iterative evolution that supports the longer term goal of producing and demonstrating a pre-manufacturing prototype ultrasonic probe that possesses the fundamental performance characteristics necessary to enable the development of a high-temperature sodium-cooled fast reactor inspection system. The scope of the work for this portion of the PNNL effort conducted in FY14 includes performing a comparative evaluation and assessment of the performance characteristics of themore » SN1 and SN2 22 element PA-UT probes manufactured at PNNL. Key transducer performance parameters, such as sound field dimensions, resolution capabilities, frequency response, and bandwidth are used as a metric for the comparative evaluation and assessment of the SN1 and SN2 engineering test units.« less

  12. An integrated earthquake early warning system and its performance at schools in Taiwan

    NASA Astrophysics Data System (ADS)

    Wu, Bing-Ru; Hsiao, Nai-Chi; Lin, Pei-Yang; Hsu, Ting-Yu; Chen, Chiou-Yun; Huang, Shieh-Kung; Chiang, Hung-Wei

    2017-01-01

    An earthquake early warning (EEW) system with integration of regional and onsite approaches was installed at nine demonstration stations in several districts of Taiwan for taking advantages of both approaches. The system performance was evaluated by a 3-year experiment at schools, which experienced five major earthquakes during this period. The blind zone of warning was effectively reduced by the integrated EEW system. The predicted intensities from EEW demonstration stations showed acceptable accuracy compared to field observations. The operation experience from an earthquake event proved that students could calmly carry out correct action before the seismic wave arrived using some warning time provided by the EEW system. Through successful operation in practice, the integrated EEW system was verified as an effective tool for disaster prevention at schools.

  13. Targeted numerical simulations of binary black holes for GW170104

    NASA Astrophysics Data System (ADS)

    Healy, J.; Lange, J.; O'Shaughnessy, R.; Lousto, C. O.; Campanelli, M.; Williamson, A. R.; Zlochower, Y.; Calderón Bustillo, J.; Clark, J. A.; Evans, C.; Ferguson, D.; Ghonge, S.; Jani, K.; Khamesra, B.; Laguna, P.; Shoemaker, D. M.; Boyle, M.; García, A.; Hemberger, D. A.; Kidder, L. E.; Kumar, P.; Lovelace, G.; Pfeiffer, H. P.; Scheel, M. A.; Teukolsky, S. A.

    2018-03-01

    In response to LIGO's observation of GW170104, we performed a series of full numerical simulations of binary black holes, each designed to replicate likely realizations of its dynamics and radiation. These simulations have been performed at multiple resolutions and with two independent techniques to solve Einstein's equations. For the nonprecessing and precessing simulations, we demonstrate the two techniques agree mode by mode, at a precision substantially in excess of statistical uncertainties in current LIGO's observations. Conversely, we demonstrate our full numerical solutions contain information which is not accurately captured with the approximate phenomenological models commonly used to infer compact binary parameters. To quantify the impact of these differences on parameter inference for GW170104 specifically, we compare the predictions of our simulations and these approximate models to LIGO's observations of GW170104.

  14. Characterizing octagonal and rectangular fibers for MAROON-X

    NASA Astrophysics Data System (ADS)

    Sutherland, Adam P.; Stuermer, Julian; Miller, Katrina R.; Seifahrt, Andreas; Bean, Jacob L.

    2016-07-01

    We report on the scrambling performance and focal-ratio-degradation (FRD) of various octagonal and rectangular fibers considered for MAROON-X. Our measurements demonstrate the detrimental effect of thin claddings on the FRD of octagonal and rectangular fibers and that stress induced at the connectors can further increase the FRD. We find that fibers with a thick, round cladding show low FRD. We further demonstrate that the scrambling behavior of non-circular fibers is often complex and introduce a new metric to fully capture non-linear scrambling performance, leading to much lower scrambling gain values than are typically reported in the literature (<=1000 compared to 10,000 or more). We find that scrambling gain measurements for small-core, non-circular fibers are often speckle dominated if the fiber is not agitated.

  15. A seismic optimization procedure for reinforced concrete framed buildings based on eigenfrequency optimization

    NASA Astrophysics Data System (ADS)

    Arroyo, Orlando; Gutiérrez, Sergio

    2017-07-01

    Several seismic optimization methods have been proposed to improve the performance of reinforced concrete framed (RCF) buildings; however, they have not been widely adopted among practising engineers because they require complex nonlinear models and are computationally expensive. This article presents a procedure to improve the seismic performance of RCF buildings based on eigenfrequency optimization, which is effective, simple to implement and efficient. The method is used to optimize a 10-storey regular building, and its effectiveness is demonstrated by nonlinear time history analyses, which show important reductions in storey drifts and lateral displacements compared to a non-optimized building. A second example for an irregular six-storey building demonstrates that the method provides benefits to a wide range of RCF structures and supports the applicability of the proposed method.

  16. Evaluation of an Atmosphere Revitalization Subsystem for Deep Space Exploration Missions

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.; Abney, Morgan B.; Conrad, Ruth E.; Frederick, Kenneth R.; Greenwood, Zachary W.; Kayatin, Matthew J.; Knox, James C.; Newton, Robert L.; Parrish, Keith J.; Takada, Kevin C.; hide

    2015-01-01

    An Atmosphere Revitalization Subsystem (ARS) suitable for deployment aboard deep space exploration mission vehicles has been developed and functionally demonstrated. This modified ARS process design architecture was derived from the International Space Station's (ISS) basic ARS. Primary functions considered in the architecture include trace contaminant control, carbon dioxide removal, carbon dioxide reduction, and oxygen generation. Candidate environmental monitoring instruments were also evaluated. The process architecture rearranges unit operations and employs equipment operational changes to reduce mass, simplify, and improve the functional performance for trace contaminant control, carbon dioxide removal, and oxygen generation. Results from integrated functional demonstration are summarized and compared to the performance observed during previous testing conducted on an ISS-like subsystem architecture and a similarly evolved process architecture. Considerations for further subsystem architecture and process technology development are discussed.

  17. A Comparison of the Capability of Sensitivity Level 3 and Sensitivity Level 4 Fluorescent Penetrants to Detect Fatigue Cracks in Various Metals

    NASA Technical Reports Server (NTRS)

    Parker, Bradford H.

    2011-01-01

    In April 2008, NASA-STD-5009 established a requirement that only sensitivity level 4 penetrants are acceptable for NASA Standard Level liquid penetrant inspections. Having NASA contractors change existing processes or perform demonstration tests to certify sensitivity level 3 penetrants posed a potentially huge cost to the Agency. This study was conducted to directly compare the probability of detection (POD) of sensitivity level 3 and level 4 penetrants using both Method A and Method D inspection processes. POD demonstration tests were performed on 6061-Al, Haynes 188 and Ti-6Al-4V crack panel sets. The study results strongly support the conclusion that sensitivity level 3 penetrants are acceptable for NASA Standard Level inspections.

  18. A passivity based control methodology for flexible joint robots with application to a simplified shuttle RMS arm

    NASA Technical Reports Server (NTRS)

    Sicard, Pierre; Wen, John T.

    1991-01-01

    The main goal is to develop a general theory for the control of flexible robots, including flexible joint robots, flexible link robots, rigid bodies with flexible appendages, etc. As part of the validation, the theory is applied to the control law development for a test example which consists of a three-link arm modeled after the shoulder yaw joint of the space shuttle remote manipulator system (RMS). The performance of the closed loop control system is then compared with the performance of the existing RMS controller to demonstrate the effectiveness of the proposed approach. The theoretical foundation of this new approach to the control of flexible robots is presented and its efficacy is demonstrated through simulation results on the three-link test arm.

  19. Concentric Rings K-Space Trajectory for Hyperpolarized 13C MR Spectroscopic Imaging

    PubMed Central

    Jiang, Wenwen; Lustig, Michael; Larson, Peder E.Z.

    2014-01-01

    Purpose To develop a robust and rapid imaging technique for hyperpolarized 13C MR Spectroscopic Imaging (MRSI) and investigate its performance. Methods A concentric rings readout trajectory with constant angular velocity is proposed for hyperpolarized 13C spectroscopic imaging and its properties are analyzed. Quantitative analyses of design tradeoffs are presented for several imaging scenarios. The first application of concentric rings on 13C phantoms and in vivo animal hyperpolarized 13C MRSI studies were performed to demonstrate the feasibility of the proposed method. Finally, a parallel imaging accelerated concentric rings study is presented. Results The concentric rings MRSI trajectory has the advantages of acquisition timesaving compared to echo-planar spectroscopic imaging (EPSI). It provides sufficient spectral bandwidth with relatively high SNR efficiency compared to EPSI and spiral techniques. Phantom and in vivo animal studies showed good image quality with half the scan time and reduced pulsatile flow artifacts compared to EPSI. Parallel imaging accelerated concentric rings showed advantages over Cartesian sampling in g-factor simulations and demonstrated aliasing-free image quality in a hyperpolarized 13C in vivo study. Conclusion The concentric rings trajectory is a robust and rapid imaging technique that fits very well with the speed, bandwidth, and resolution requirements of hyperpolarized 13C MRSI. PMID:25533653

  20. Emotional intelligence in anorexia nervosa: is anxiety a missing piece of the puzzle?

    PubMed

    Hambrook, David; Brown, Gary; Tchanturia, Kate

    2012-11-30

    Problematic emotional processing has been implicated in the genesis and maintenance of anorexia nervosa (AN). This study built on existing research and explored performance-based emotional intelligence (EI) in people with AN. The Mayer-Salovey-Caruso Emotional Intelligence Test (MSCEIT) was administered to 32 women diagnosed with AN and 32 female healthy controls (HC). Compared to HC women, the AN group demonstrated significantly lower total EI scores and poorer ability to understand how emotions can progress and change over time. Despite scores within the broadly average range compared to published EI norms, there was a general pattern of poorer performance in the AN sample. Self-reported anxiety symptoms were the strongest predictor of EI, over and above a diagnosis of AN. This study adds to the literature documenting the socioemotional phenotype of AN, suggesting this group of individuals may find it relatively difficult to carry out accurate reasoning about emotions, and to use emotions and emotional knowledge to enhance thought. Anxiety was highlighted as a putative variable partially explaining why people with AN demonstrated lower EI compared to controls. Implications for further research are discussed, including the need to explore the specificity of EI difficulties in AN using larger samples and additional control groups. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Comparative Analysis of a Principal Component Analysis-Based and an Artificial Neural Network-Based Method for Baseline Removal.

    PubMed

    Carvajal, Roberto C; Arias, Luis E; Garces, Hugo O; Sbarbaro, Daniel G

    2016-04-01

    This work presents a non-parametric method based on a principal component analysis (PCA) and a parametric one based on artificial neural networks (ANN) to remove continuous baseline features from spectra. The non-parametric method estimates the baseline based on a set of sampled basis vectors obtained from PCA applied over a previously composed continuous spectra learning matrix. The parametric method, however, uses an ANN to filter out the baseline. Previous studies have demonstrated that this method is one of the most effective for baseline removal. The evaluation of both methods was carried out by using a synthetic database designed for benchmarking baseline removal algorithms, containing 100 synthetic composed spectra at different signal-to-baseline ratio (SBR), signal-to-noise ratio (SNR), and baseline slopes. In addition to deomonstrating the utility of the proposed methods and to compare them in a real application, a spectral data set measured from a flame radiation process was used. Several performance metrics such as correlation coefficient, chi-square value, and goodness-of-fit coefficient were calculated to quantify and compare both algorithms. Results demonstrate that the PCA-based method outperforms the one based on ANN both in terms of performance and simplicity. © The Author(s) 2016.

  2. Forensic Drug Identification, Confirmation, and Quantification Using Fully Integrated Gas Chromatography with Fourier Transform Infrared and Mass Spectrometric Detection (GC-FT-IR-MS).

    PubMed

    Lanzarotta, Adam; Lorenz, Lisa; Voelker, Sarah; Falconer, Travis M; Batson, JaCinta S

    2018-05-01

    This manuscript is a continuation of a recent study that described the use of fully integrated gas chromatography with direct deposition Fourier transform infrared detection and mass spectrometric detection (GC-FT-IR-MS) to identify and confirm the presence of sibutramine and AB-FUBINACA. The purpose of the current study was to employ the GC-FT-IR portion of the same instrument to quantify these compounds, thereby demonstrating the ability to identify, confirm, and quantify drug substances using a single GC-FT-IR-MS unit. The performance of the instrument was evaluated by comparing quantitative analytical figures of merit to those measured using an established, widely employed method for quantifying drug substances, high performance liquid chromatography with ultraviolet detection (HPLC-UV). The results demonstrated that GC-FT-IR was outperformed by HPLC-UV with regard to sensitivity, precision, and linear dynamic range (LDR). However, sibutramine and AB-FUBINACA concentrations measured using GC-FT-IR were not significantly different at the 95% confidence interval compared to those measured using HPLC-UV, which demonstrates promise for using GC-FT-IR as a semi-quantitative tool at the very least. The most significant advantage of GC-FT-IR compared to HPLC-UV is selectivity; a higher level of confidence regarding the identity of the analyte being quantified is achieved using GC-FT-IR. Additional advantages of using a single GC-FT-IR-MS instrument for identification, confirmation, and quantification are efficiency, increased sample throughput, decreased consumption of laboratory resources (solvents, chemicals, consumables, etc.), and thus cost.

  3. Surface engineered porous silicon for stable, high performance electrochemical supercapacitors

    PubMed Central

    Oakes, Landon; Westover, Andrew; Mares, Jeremy W.; Chatterjee, Shahana; Erwin, William R.; Bardhan, Rizia; Weiss, Sharon M.; Pint, Cary L.

    2013-01-01

    Silicon materials remain unused for supercapacitors due to extreme reactivity of silicon with electrolytes. However, doped silicon materials boast a low mass density, excellent conductivity, a controllably etched nanoporous structure, and combined earth abundance and technological presence appealing to diverse energy storage frameworks. Here, we demonstrate a universal route to transform porous silicon (P-Si) into stable electrodes for electrochemical devices through growth of an ultra-thin, conformal graphene coating on the P-Si surface. This graphene coating simultaneously passivates surface charge traps and provides an ideal electrode-electrolyte electrochemical interface. This leads to 10–40X improvement in energy density, and a 2X wider electrochemical window compared to identically-structured unpassivated P-Si. This work demonstrates a technique generalizable to mesoporous and nanoporous materials that decouples the engineering of electrode structure and electrochemical surface stability to engineer performance in electrochemical environments. Specifically, we demonstrate P-Si as a promising new platform for grid-scale and integrated electrochemical energy storage. PMID:24145684

  4. Surface engineered porous silicon for stable, high performance electrochemical supercapacitors.

    PubMed

    Oakes, Landon; Westover, Andrew; Mares, Jeremy W; Chatterjee, Shahana; Erwin, William R; Bardhan, Rizia; Weiss, Sharon M; Pint, Cary L

    2013-10-22

    Silicon materials remain unused for supercapacitors due to extreme reactivity of silicon with electrolytes. However, doped silicon materials boast a low mass density, excellent conductivity, a controllably etched nanoporous structure, and combined earth abundance and technological presence appealing to diverse energy storage frameworks. Here, we demonstrate a universal route to transform porous silicon (P-Si) into stable electrodes for electrochemical devices through growth of an ultra-thin, conformal graphene coating on the P-Si surface. This graphene coating simultaneously passivates surface charge traps and provides an ideal electrode-electrolyte electrochemical interface. This leads to 10-40X improvement in energy density, and a 2X wider electrochemical window compared to identically-structured unpassivated P-Si. This work demonstrates a technique generalizable to mesoporous and nanoporous materials that decouples the engineering of electrode structure and electrochemical surface stability to engineer performance in electrochemical environments. Specifically, we demonstrate P-Si as a promising new platform for grid-scale and integrated electrochemical energy storage.

  5. Surface engineered porous silicon for stable, high performance electrochemical supercapacitors

    NASA Astrophysics Data System (ADS)

    Oakes, Landon; Westover, Andrew; Mares, Jeremy W.; Chatterjee, Shahana; Erwin, William R.; Bardhan, Rizia; Weiss, Sharon M.; Pint, Cary L.

    2013-10-01

    Silicon materials remain unused for supercapacitors due to extreme reactivity of silicon with electrolytes. However, doped silicon materials boast a low mass density, excellent conductivity, a controllably etched nanoporous structure, and combined earth abundance and technological presence appealing to diverse energy storage frameworks. Here, we demonstrate a universal route to transform porous silicon (P-Si) into stable electrodes for electrochemical devices through growth of an ultra-thin, conformal graphene coating on the P-Si surface. This graphene coating simultaneously passivates surface charge traps and provides an ideal electrode-electrolyte electrochemical interface. This leads to 10-40X improvement in energy density, and a 2X wider electrochemical window compared to identically-structured unpassivated P-Si. This work demonstrates a technique generalizable to mesoporous and nanoporous materials that decouples the engineering of electrode structure and electrochemical surface stability to engineer performance in electrochemical environments. Specifically, we demonstrate P-Si as a promising new platform for grid-scale and integrated electrochemical energy storage.

  6. Multimode intravascular RF coil for MRI-guided interventions.

    PubMed

    Kurpad, Krishna N; Unal, Orhan

    2011-04-01

    To demonstrate the feasibility of using a single intravascular radiofrequency (RF) probe connected to the external magnetic resonance imaging (MRI) system via a single coaxial cable to perform active tip tracking and catheter visualization and high signal-to-noise ratio (SNR) intravascular imaging. A multimode intravascular RF coil was constructed on a 6F balloon catheter and interfaced to a 1.5T MRI scanner via a decoupling circuit. Bench measurements of coil impedances were followed by imaging experiments in saline and phantoms. The multimode coil behaves as an inductively coupled transmit coil. The forward-looking capability of 6 mm was measured. A greater than 3-fold increase in SNR compared to conventional imaging using optimized external coil was demonstrated. Simultaneous active tip tracking and catheter visualization was demonstrated. It is feasible to perform 1) active tip tracking, 2) catheter visualization, and 3) high SNR imaging using a single multimode intravascular RF coil that is connected to the external system via a single coaxial cable. Copyright © 2011 Wiley-Liss, Inc.

  7. Multi-mode Intravascular RF Coil for MRI-guided Interventions

    PubMed Central

    Kurpad, Krishna N.; Unal, Orhan

    2011-01-01

    Purpose To demonstrate the feasibility of using a single intravascular RF probe connected to the external MRI system via a single coaxial cable to perform active tip tracking and catheter visualization, and high SNR intravascular imaging. Materials and Methods A multi-mode intravascular RF coil was constructed on a 6F balloon catheter and interfaced to a 1.5T MRI scanner via a decoupling circuit. Bench measurements of coil impedances were followed by imaging experiments in saline and phantoms. Results The multi-mode coil behaves as an inductively-coupled transmit coil. Forward looking capability of 6mm is measured. Greater than 3-fold increase in SNR compared to conventional imaging using optimized external coil is demonstrated. Simultaneous active tip tracking and catheter visualization is demonstrated. Conclusions It is feasible to perform 1) active tip tracking, 2) catheter visualization, and 3) high SNR imaging using a single multi-mode intravascular RF coil that is connected to the external system via a single coaxial cable. PMID:21448969

  8. Surfactant protein-A nanobody-conjugated liposomes loaded with methylprednisolone increase lung-targeting specificity and therapeutic effect for acute lung injury.

    PubMed

    Li, Nan; Weng, Dong; Wang, Shan-Mei; Zhang, Yuan; Chen, Shan-Shan; Yin, Zhao-Fang; Zhai, Jiali; Scoble, Judy; Williams, Charlotte C; Chen, Tao; Qiu, Hui; Wu, Qin; Zhao, Meng-Meng; Lu, Li-Qin; Mulet, Xavier; Li, Hui-Ping

    2017-11-01

    The advent of nanomedicine requires novel delivery vehicles to actively target their site of action. Here, we demonstrate the development of lung-targeting drug-loaded liposomes and their efficacy, specificity and safety. Our study focuses on glucocorticoids methylprednisolone (MPS), a commonly used drug to treat lung injuries. The steroidal molecule was loaded into functionalized nano-sterically stabilized unilamellar liposomes (NSSLs). Targeting functionality was performed through conjugation of surfactant protein A (SPANb) nanobodies to form MPS-NSSLs-SPANb. MPS-NSSLs-SPANb exhibited good size distribution, morphology, and encapsulation efficiency. Animal experiments demonstrated the high specificity of MPS-NSSLs-SPANb to the lung. Treatment with MPS-NSSLs-SPANb reduced the levels of TNF-α, IL-8, and TGF-β1 in rat bronchoalveolar lavage fluid and the expression of NK-κB in the lung tissues, thereby alleviating lung injuries and increasing rat survival. The nanobody functionalized nanoparticles demonstrate superior performance to treat lung injury when compared to that of antibody functionalized systems.

  9. Athletic background is related to superior trunk proprioceptive ability, postural control, and neuromuscular responses to sudden perturbations.

    PubMed

    Glofcheskie, Grace O; Brown, Stephen H M

    2017-04-01

    Trunk motor control is essential for athletic performance, and inadequate trunk motor control has been linked to an increased risk of developing low back and lower limb injury in athletes. Research is limited in comparing relationships between trunk neuromuscular control, postural control, and trunk proprioception in athletes from different sporting backgrounds. To test for these relationships, collegiate level long distance runners and golfers, along with non-athletic controls were recruited. Trunk postural control was investigated using a seated balance task. Neuromuscular control in response to sudden trunk loading perturbations was measured using electromyography and kinematics. Proprioceptive ability was examined using active trunk repositioning tasks. Both athlete groups demonstrated greater trunk postural control (less centre of pressure movement) during the seated task compared to controls. Athletes further demonstrated faster trunk muscle activation onsets, higher muscle activation amplitudes, and less lumbar spine angular displacement in response to sudden trunk loading perturbations when compared to controls. Golfers demonstrated less absolute error and variable error in trunk repositioning tasks compared to both runners and controls, suggestive of greater proprioceptive ability. This suggests an interactive relationship between neuromuscular control, postural control, and proprioception in athletes, and that differences exist between athletes of various training backgrounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Semantic Mapping and Motion Planning with Turtlebot Roomba

    NASA Astrophysics Data System (ADS)

    Aslam Butt, Rizwan; Usman Ali, Syed M.

    2013-12-01

    In this paper, we have successfully demonstrated the semantic mapping and motion planning experiments on Turtlebot Robot using Microsoft Kinect in ROS environment. Moreover, we have also performed the comparative studies on various sampling based motion planning algorithms with Turtlebot in Open Motion Planning Library. Our comparative analysis revealed that Expansive Space Trees (EST) surmounted all other approaches with respect to memory occupation and processing time. We have also tried to summarize the related concepts of autonomous robotics which we hope would be helpful for beginners.

  11. Comparing the Efficiencies of Third Molar Surgeries With and Without a Dentist Anesthesiologist.

    PubMed

    Reebye, Uday; Young, S; Boukas, E; Davidian, E; Carnahan, J

    2017-01-01

    Two different anesthesia models were compared in terms of surgical duration, safer outcomes, and economic implications. Third molar surgeries performed with and without a separate dentist anesthesiologist were evaluated by a retrospective data analysis of the surgical operative times. For more difficult surgeries, substantially shorter operative times were observed with the dentist anesthesiologist model, leading to a more favorable surgical outcome. An example calculation is presented to demonstrate economic advantages of scheduling the participation of a dentist anesthesiologist for more difficult surgeries.

  12. Comparative studies of copy number variation detection methods for next-generation sequencing technologies.

    PubMed

    Duan, Junbo; Zhang, Ji-Gang; Deng, Hong-Wen; Wang, Yu-Ping

    2013-01-01

    Copy number variation (CNV) has played an important role in studies of susceptibility or resistance to complex diseases. Traditional methods such as fluorescence in situ hybridization (FISH) and array comparative genomic hybridization (aCGH) suffer from low resolution of genomic regions. Following the emergence of next generation sequencing (NGS) technologies, CNV detection methods based on the short read data have recently been developed. However, due to the relatively young age of the procedures, their performance is not fully understood. To help investigators choose suitable methods to detect CNVs, comparative studies are needed. We compared six publicly available CNV detection methods: CNV-seq, FREEC, readDepth, CNVnator, SegSeq and event-wise testing (EWT). They are evaluated both on simulated and real data with different experiment settings. The receiver operating characteristic (ROC) curve is employed to demonstrate the detection performance in terms of sensitivity and specificity, box plot is employed to compare their performances in terms of breakpoint and copy number estimation, Venn diagram is employed to show the consistency among these methods, and F-score is employed to show the overlapping quality of detected CNVs. The computational demands are also studied. The results of our work provide a comprehensive evaluation on the performances of the selected CNV detection methods, which will help biological investigators choose the best possible method.

  13. Producibility of Vertically Integrated Photodiode (VIP)tm scanning focal plane arrays

    NASA Astrophysics Data System (ADS)

    Turner, Arthur M.; Teherani, Towfik; Ehmke, John C.; Pettitt, Cindy; Conlon, Peggy; Beck, Jeffrey D.; McCormack, Kent; Colombo, Luigi; Lahutsky, Tom; Murphy, Terry; Williams, Robert L.

    1994-07-01

    Vertically integrated photodiode, VIPTM, technology is now being used to produce second generation infrared focal plane arrays with high yields and performance. The VIPTM process employs planar, ion implanted, n on p diodes in HgCdTe which is epoxy hybridized directly to the read out integrated circuits on 100 mm Si wafers. The process parameters that are critical for high performance and yield include: HgCdTe dislocation density and thickness, backside passivation, frontside passivation, and junction formation. Producibility of infrared focal plane arrays (IRFPAs) is also significantly enhanced by read out integrated circuits (ROICs) which have the ability to deselect defective pixels. Cold probe screening before lab dewar assembly reduces costs and improves cycle times. The 240 X 1 and 240 X 2 scanning array formats are used to demonstrate the effect of process optimization, deselect, and cold probe screening on yield and cycle time. The versatility of the VIPTM technology and its extension to large area arrays is demonstrated using 240/288 X 4 and 480 X 5 TDI formats. Finally, the high performance of VIPTM IRFPAs is demonstrated by comparing data from a 480 X 5 to the SADA-II specification.

  14. Impaired orienting in youth with Internet Addiction: Evidence from the Attention Network Task (ANT).

    PubMed

    Fu, Jia; Xu, Peng; Zhao, Lun; Yu, Guoming

    2018-06-01

    An important theory of attention suggests that there are three separate networks that execute discrete cognitive functions: alerting, orienting and conflict networks. Recent studies showed that there was a dysfunction of attention in Internet Addiction. In order to investigate the underlying mechanism of attention dysfunction in Internet Addiction, we recorded performance related to the Attentional Network Test (ANT) in youth. The ANT, a behavioral assay of the functional integrity of attention networks, was used to examine the performance in Internet Addiction and healthy controls. Performance on the ANT clearly differentiated the participants with and without Internet Addiction in terms of mean reaction times (RTs). Compared with control group, the Internet Addiction group detected targets more slowly and this effect was evident only for spatial cue condition. The Internet Addiction group demonstrated deficits in the orienting network in terms of slower RT. There was no demonstration of a deficit in both the alerting and conflict network in Internet Addiction on this task. The youth with Internet Addiction demonstrated deficits in the orienting network but normal functioning of the alerting and conflict attention networks. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Efficiency of bowel preparation for capsule endoscopy examination: a meta-analysis.

    PubMed

    Niv, Yaron

    2008-03-07

    Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as "good" in 78% of the examinations performed with preparation and 49% performed without (P<0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum.

  16. Efficiency of bowel preparation for capsule endoscopy examination: A meta-analysis

    PubMed Central

    Niv, Yaron

    2008-01-01

    Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as “good” in 78% of the examinations performed with preparation and 49% performed without (P < 0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum. PMID:18322940

  17. LDRD Report: Topological Design Optimization of Convolutes in Next Generation Pulsed Power Devices.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cyr, Eric C.; von Winckel, Gregory John; Kouri, Drew Philip

    This LDRD project was developed around the ambitious goal of applying PDE-constrained opti- mization approaches to design Z-machine components whose performance is governed by elec- tromagnetic and plasma models. This report documents the results of this LDRD project. Our differentiating approach was to use topology optimization methods developed for structural design and extend them for application to electromagnetic systems pertinent to the Z-machine. To achieve this objective a suite of optimization algorithms were implemented in the ROL library part of the Trilinos framework. These methods were applied to standalone demonstration problems and the Drekar multi-physics research application. Out of thismore » exploration a new augmented Lagrangian approach to structural design problems was developed. We demonstrate that this approach has favorable mesh-independent performance. Both the final design and the algorithmic performance were independent of the size of the mesh. In addition, topology optimization formulations for the design of conducting networks were developed and demonstrated. Of note, this formulation was used to develop a design for the inner magnetically insulated transmission line on the Z-machine. The resulting electromagnetic device is compared with theoretically postulated designs.« less

  18. Remote Excavation System technology evaluation report: Buried Waste Robotics Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-09-01

    This document describes the results from the Remote Excavation System demonstration and testing conducted at the Idaho National Engineering Laboratory during June and July 1993. The purpose of the demonstration was to ascertain the feasibility of the system for skimming soil and removing various types of buried waste in a safe manner and within all regulatory requirements, and to compare the performances of manual and remote operation of a backhoe. The procedures and goals of the demonstration were previously defined in The Remote Excavation System Test Plan, which served as a guideline for evaluating the various components of the systemmore » and discussed the procedures used to conduct the tests.« less

  19. Tailored Codes for Small Quantum Memories

    NASA Astrophysics Data System (ADS)

    Robertson, Alan; Granade, Christopher; Bartlett, Stephen D.; Flammia, Steven T.

    2017-12-01

    We demonstrate that small quantum memories, realized via quantum error correction in multiqubit devices, can benefit substantially by choosing a quantum code that is tailored to the relevant error model of the system. For a biased noise model, with independent bit and phase flips occurring at different rates, we show that a single code greatly outperforms the well-studied Steane code across the full range of parameters of the noise model, including for unbiased noise. In fact, this tailored code performs almost optimally when compared with 10 000 randomly selected stabilizer codes of comparable experimental complexity. Tailored codes can even outperform the Steane code with realistic experimental noise, and without any increase in the experimental complexity, as we demonstrate by comparison in the observed error model in a recent seven-qubit trapped ion experiment.

  20. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    NASA Astrophysics Data System (ADS)

    Mirarchi, D.; Hall, G.; Redaelli, S.; Scandale, W.

    2017-06-01

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going.

  1. Resistance training performed at distinct angular velocities elicits velocity-specific alterations in muscle strength and mobility status in older adults.

    PubMed

    Englund, Davis A; Sharp, Rick L; Selsby, Joshua T; Ganesan, Shanthi S; Franke, Warren D

    2017-05-01

    The purpose of this study was to compare the effects of high and low velocity knee extension training on changes in muscle strength and mobility status in high-functioning older adults. Twenty-six (16 female, 10 male) older adults (mean age of 65) were randomized to either 6weeks of low velocity resistance training (LVRT) performed at 75°/s or high velocity resistance training (HVRT) performed at 240°/s. Both groups performed 3 sets of knee extension exercises at maximal effort, 3 times a week. Muscle strength was assessed through a range of testing velocities on an isokinetic dynamometer. Mobility status was assessed with the short physical performance battery (SPPB) and myosin heavy chain (MyHC) transcript levels were quantified via qRT-PCR. From baseline to post-training, there were several significant (P<0.05) differences in muscle strength and functional characteristics in LVRT (n=13) and HVRT (n=13) groups. From baseline to post-training, MyHC-α mRNA and MyHC-IIa mRNA showed a significant (P<0.05) increase within HVRT but MyHC-IIx mRNA did not change significantly. Our results demonstrate HVRT provides a greater number of muscular enhancements when compared to LVRT, particularly under conditions of high velocity muscle contraction. HVRT is emerging as the optimal training stimulus for the older adult. The present study demonstrates, in addition to increased strength and functional outcomes, HVRT elicits a potentially therapeutic (i.e., slow to fast) transcriptional response in MyHC. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Self-perceived versus objectively measured competence in performing clinical practical procedures by final year medical students

    PubMed Central

    Banda, Sekelani

    2016-01-01

    Objectives To determine and compare the self-perceived and objectively measured competence in performing 14 core-clinical practical procedures by Final Year Medical Students of the University of Zambia. Methods The study included 56 out of 60 graduating University of Zambia Medical Students of the 2012/2013 academic year. Self-perceived competence: students rated their competence on 14 core- clinical practical procedures using a self-administered questionnaire on a 5-point Likert scale. Objective competence: it was measured by Objective Structured Clinical Examination (OSCE) by faculty using predetermined rating scales. Rank order correlation test was performed for self-perceived and objectively measured competence. Results Two thirds 36 (66.7%) of the participants perceived themselves as moderately competent, 15 (27.8%) rated themselves as highly competent while 3 (5.6%) had low self-perception. With objective competence, the majority 52 (92.8%) were barely competent while 4 (7.2%) were absolutely competent. When overall self-perception was compared to objectively measured competence, there was a discordance which was demonstrated by a negative correlation (Spearman rho -.123). Conclusions Significant numbers of students reported low self-competence in performing procedures such as endotracheal intubation, gastric lavage and cardiopulmonary resuscitation which most never performed during the clinical years of medical education. In addition, the negative correlation between self-perceived and objectively measured competence demonstrated the inability of students to assess and rate themselves objectively due to fear that others may know their weaknesses and realize that they are not as competent as expected at a specific level of training. PMID:27132255

  3. Self-perceived versus objectively measured competence in performing clinical practical procedures by final year medical students.

    PubMed

    Katowa-Mukwato, Patricia; Banda, Sekelani

    2016-04-30

    To determine and compare the self-perceived and objectively measured competence in performing 14 core-clinical practical procedures by Final Year Medical Students of the University of Zambia. The study included 56 out of 60 graduating University of Zambia Medical Students of the 2012/2013 academic year. Self-perceived competence: students rated their competence on 14 core- clinical practical procedures using a self-administered questionnaire on a 5-point Likert scale. Objective competence: it was measured by Objective Structured Clinical Examination (OSCE) by faculty using predetermined rating scales. Rank order correlation test was performed for self-perceived and objectively measured competence. Two thirds 36 (66.7%) of the participants perceived themselves as moderately competent, 15 (27.8%) rated themselves as highly competent while 3 (5.6%) had low self-perception. With objective competence, the majority 52 (92.8%) were barely competent while 4 (7.2%) were absolutely competent. When overall self-perception was compared to objectively measured competence, there was a discordance which was demonstrated by a negative correlation (Spearman rho -.123). Significant numbers of students reported low self-competence in performing procedures such as endotracheal intubation, gastric lavage and cardiopulmonary resuscitation which most never performed during the clinical years of medical education. In addition, the negative correlation between self-perceived and objectively measured competence demonstrated the inability of students to assess and rate themselves objectively due to fear that others may know their weaknesses and realize that they are not as competent as expected at a specific level of training.

  4. Mild cognitive impairment and everyday function: evidence of reduced speed in performing instrumental activities of daily living.

    PubMed

    Wadley, Virginia G; Okonkwo, Ozioma; Crowe, Michael; Ross-Meadows, Lesley A

    2008-05-01

    Mild cognitive impairment (MCI) may involve subtle functional losses that are not detected with typical self- or informant-report assessments of daily function. Information about the nature of functional difficulties in MCI can be used to augment common clinical assessment procedures, and aspects of function that are affected in MCI can serve as meaningful endpoints for intervention trials. Cross-sectional case and comparison group study. University medical center. Fifty participants with MCI and 59 cognitively normal participants. The authors compared the groups on dimensions of both speed and accuracy in performing instrumental activities of daily living (IADLs), using a standardized Timed IADL measure that evaluates five functional domains commonly encountered in everyday life (telephone use, locating nutrition information on food labels, financial abilities, grocery shopping, medication management). Across Timed IADL domains, MCI participants demonstrated accuracy comparable with cognitively normal participants but took significantly longer to complete the functional activities, controlling for depressive symptoms (p< 0.001). Slower performance was demonstrated in each discrete domain except financial abilities. These results suggest that slower speed of task performance is an important component and perhaps an early marker of functional change in MCI that would not be detected using traditional measurements of daily function. Future research should address the question of whether performance-based functional measures, as well as simple queries regarding whether functional activities take longer than usual to complete, may improve the prediction of future cognitive decline and disease progression among those individuals in whom MCI represents impending dementia.

  5. Acoustic Analysis and Electroglottography in Elite Vocal Performers.

    PubMed

    Villafuerte-Gonzalez, Rocio; Valadez-Jimenez, Victor M; Sierra-Ramirez, Jose A; Ysunza, Pablo Antonio; Chavarria-Villafuerte, Karen; Hernandez-Lopez, Xochiquetzal

    2017-05-01

    Acoustic analysis of voice (AAV) and electroglottography (EGG) have been used for assessing vocal quality in patients with voice disorders. The effectiveness of these procedures for detecting mild disturbances in vocal quality in elite vocal performers has been controversial. To compare acoustic parameters obtained by AAV and EGG before and after vocal training to determine the effectiveness of these procedures for detecting vocal improvements in elite vocal performers. Thirty-three elite vocal performers were studied. The study group included 14 males and 19 females, ages 18-40 years, without a history of voice disorders. Acoustic parameters were obtained through AAV and EGG before and after vocal training using the Linklater method. Nonsignificant differences (P > 0.05) were found between values of fundamental frequency (F 0 ), shimmer, and jitter obtained by both procedures before vocal training. Mean F 0 was similar after vocal training. Jitter percentage as measured by AAV showed nonsignificant differences (P > 0.05) before and after vocal training. Shimmer percentage as measured by AAV demonstrated a significant reduction (P < 0.05) after vocal training. As measured by EGG after vocal training, shimmer and jitter were significantly reduced (P < 0.05); open quotient was significantly increased (P < 0.05); and irregularity was significantly reduced (P < 0.05). AAV and EGG were effective for detecting improvements in vocal function after vocal training in male and female elite vocal performers undergoing vocal training. EGG demonstrated better efficacy for detecting improvements and provided additional parameters as compared to AAV. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  6. Diffraction-limited lucky imaging with a 12" commercial telescope

    NASA Astrophysics Data System (ADS)

    Baptista, Brian J.

    2014-08-01

    Here we demonstrate a novel lucky imaging camera which is designed to produce diffraction-limited imaging using small telescopes similar to ones used by many academic institutions for outreach and/or student training. We present a design that uses a Meade 12" SCT paired with an Andor iXon fast readout EMCCD. The PSF of the telescope is matched to the pixel size of the EMCCD by adding a simple, custom-fabricated, intervening optical system. We demonstrate performance of the system by observing both astronomical and terrestrial targets. The astronomical application requires simpler data reconstruction techniques as compared to the terrestrial case. We compare different lucky imaging registration and reconstruction algorithms for use with this imager for both astronomical and terrestrial targets. We also demonstrate how this type of instrument would be useful for both undergraduate and graduate student training. As an instructional aide, the instrument can provide a hands-on approach for teaching instrument design, standard data reduction techniques, lucky imaging data processing, and high resolution imaging concepts.

  7. Modeling and development of a twisting wing using inductively heated shape memory alloy actuators

    NASA Astrophysics Data System (ADS)

    Saunders, Robert N.; Hartl, Darren J.; Boyd, James G.; Lagoudas, Dimitris C.

    2015-04-01

    Wing twisting has been shown to improve aircraft flight performance. The potential benefits of a twisting wing are often outweighed by the mass of the system required to twist the wing. Shape memory alloy (SMA) actuators repeatedly demonstrate abilities and properties that are ideal for aerospace actuation systems. Recent advances have shown an SMA torsional actuator that can be manufactured and trained with the ability to generate large twisting deformations under substantial loading. The primary disadvantage of implementing large SMA actuators has been their slow actuation time compared to conventional actuators. However, inductive heating of an SMA actuator allows it to generate a full actuation cycle in just seconds rather than minutes while still . The aim of this work is to demonstrate an experimental wing being twisted to approximately 10 degrees by using an inductively heated SMA torsional actuator. This study also considers a 3-D electromagnetic thermo-mechanical model of the SMA-wing system and compare these results to experiments to demonstrate modeling capabilities.

  8. A Murine Model of Robotic Training to Evaluate Skeletal Muscle Recovery after Injury.

    PubMed

    Lai, Stefano; Panarese, Alessandro; Lawrence, Ross; Boninger, Michael L; Micera, Silvestro; Ambrosio, Fabrisia

    2017-04-01

    In vivo studies have suggested that motor exercise can improve muscle regeneration after injury. Nevertheless, preclinical investigations still lack reliable tools to monitor motor performance over time and to deliver optimal training protocols to maximize force recovery. Here, we evaluated the utility of a murine robotic platform (i) to detect early impairment and longitudinal recovery after acute skeletal muscle injury and (ii) to administer varying intensity training protocols to enhance forelimb motor performance. A custom-designed robotic platform was used to train mice to perform a forelimb retraction task. After an acute injury to bilateral biceps brachii muscles, animals performed a daily training protocol in the platform at high (HL) or low (LL) loading levels over the course of 3 wk. Control animals were not trained (NT). Motor performance was assessed by quantifying force, time, submovement count, and number of movement attempts to accomplish the task. Myofiber number and cross-sectional area at the injury site were quantified histologically. Two days after injury, significant differences in the time, submovement count, number of movement attempts, and exerted force were observed in all mice, as compared with baseline values. Interestingly, the recovery time of muscle force production differed significantly between intervention groups, with HL group showing a significantly accelerated recovery. Three weeks after injury, all groups showed motor performance comparable with baseline values. Accordingly, there were no differences in the number of myofibers or average cross-sectional area among groups after 3 wk. Our findings demonstrate the utility of our custom-designed robotic device for the quantitative assessment of skeletal muscle function in preclinical murine studies. Moreover, we demonstrate that this device may be used to apply varying levels of resistance longitudinally as a means manipulate physiological muscle responses.

  9. Characterization of in-flight performance of ion propulsion systems

    NASA Astrophysics Data System (ADS)

    Sovey, James S.; Rawlin, Vincent K.

    1993-06-01

    In-flight measurements of ion propulsion performance, ground test calibrations, and diagnostic performance measurements were reviewed. It was found that accelerometers provided the most accurate in-flight thrust measurements compared with four other methods that were surveyed. An experiment has also demonstrated that pre-flight alignment of the thrust vector was sufficiently accurate so that gimbal adjustments and use of attitude control thrusters were not required to counter disturbance torques caused by thrust vector misalignment. The effects of facility background pressure, facility enhanced charge-exchange reactions, and contamination on ground-based performance measurements are also discussed. Vacuum facility pressures for inert-gas ion thruster life tests and flight qualification tests will have to be less than 2 mPa to ensure accurate performance measurements.

  10. Characterization of in-flight performance of ion propulsion systems

    NASA Technical Reports Server (NTRS)

    Sovey, James S.; Rawlin, Vincent K.

    1993-01-01

    In-flight measurements of ion propulsion performance, ground test calibrations, and diagnostic performance measurements were reviewed. It was found that accelerometers provided the most accurate in-flight thrust measurements compared with four other methods that were surveyed. An experiment has also demonstrated that pre-flight alignment of the thrust vector was sufficiently accurate so that gimbal adjustments and use of attitude control thrusters were not required to counter disturbance torques caused by thrust vector misalignment. The effects of facility background pressure, facility enhanced charge-exchange reactions, and contamination on ground-based performance measurements are also discussed. Vacuum facility pressures for inert-gas ion thruster life tests and flight qualification tests will have to be less than 2 mPa to ensure accurate performance measurements.

  11. ERP correlates of recognition memory in Autism Spectrum Disorder.

    PubMed

    Massand, Esha; Bowler, Dermot M; Mottron, Laurent; Hosein, Anthony; Jemel, Boutheina

    2013-09-01

    Recognition memory in autism spectrum disorder (ASD) tends to be undiminished compared to that of typically developing (TD) individuals (Bowler et al. 2007), but it is still unknown whether memory in ASD relies on qualitatively similar or different neurophysiology. We sought to explore the neural activity underlying recognition by employing the old/new word repetition event-related potential effect. Behavioural recognition performance was comparable across both groups, and demonstrated superior recognition for low frequency over high frequency words. However, the ASD group showed a parietal rather than anterior onset (300-500 ms), and diminished right frontal old/new effects (800-1500 ms) relative to TD individuals. This study shows that undiminished recognition performance results from a pattern of differing functional neurophysiology in ASD.

  12. Microfluidic Synthesis and Biological Evaluation of Photothermal Biodegradable Copper Sulfide Nanoparticles.

    PubMed

    Ortiz de Solorzano, Isabel; Prieto, Martín; Mendoza, Gracia; Alejo, Teresa; Irusta, Silvia; Sebastian, Victor; Arruebo, Manuel

    2016-08-24

    The continuous synthesis of biodegradable photothermal copper sulfide nanoparticles has been carried out with the aid of a microfluidic platform. A comparative physicochemical characterization of the resulting products from the microreactor and from a conventional batch reactor has been performed. The microreactor is able to operate in a continuous manner and with a 4-fold reduction in the synthesis times compared to that of the conventional batch reactor producing nanoparticles with the same physicochemical requirements. Biodegradation subproducts obtained under simulated physiological conditions have been identified, and a complete cytotoxicological analysis on different cell lines was performed. The photothermal effect of those nanomaterials has been demonstrated in vitro as well as their ability to generate reactive oxygen species.

  13. Numerical analyses of a rocket engine turbine and comparison with air test data

    NASA Technical Reports Server (NTRS)

    Tran, Ken; Chan, Daniel C.; Hudson, Susan T.; Gaddis, Stephen W.

    1992-01-01

    The study presents cold air test data on the Space Shuttle Main Engine High Pressure Fuel Turbopump turbine recently collected at the NASA Marshall Space Flight Center. Overall performance data, static pressures on the first- and second-stage nozzles, and static pressures along with the gas path at the hub and tip are gathered and compared with various (1D, quasi-3D, and 3D viscous) analysis procedures. The results of each level of analysis are compared to test data to demonstrate the range of applicability for each step in the design process of a turbine. One-dimensional performance prediction, quasi-3D loading prediction, 3D wall pressure distribution prediction, and 3D viscous wall pressure distribution prediction are illustrated.

  14. Microwave photonic link with improved phase noise using a balanced detection scheme

    NASA Astrophysics Data System (ADS)

    Hu, Jingjing; Gu, Yiying; Tan, Wengang; Zhu, Wenwu; Wang, Linghua; Zhao, Mingshan

    2016-07-01

    A microwave photonic link (MPL) with improved phase noise performance using a dual output Mach-Zehnder modulator (DP-MZM) and balanced detection is proposed and experimentally demonstrated. The fundamental concept of the approach is based on the two complementary outputs of DP-MZM and the destructive combination of the photocurrent in balanced photodetector (BPD). Theoretical analysis is performed to numerical evaluate the additive phase noise performance and shows a good agreement with the experiment. Experimental results are presented for 4 GHz, 8 GHz and 12 GHz transmission link and an 11 dB improvement of phase noise performance at 10 MHz offset is achieved compared to the conventional intensity-modulation and direct-detection (IMDD) MPL.

  15. Listening Effort During Sentence Processing Is Increased for Non-native Listeners: A Pupillometry Study

    PubMed Central

    Borghini, Giulia; Hazan, Valerie

    2018-01-01

    Current evidence demonstrates that even though some non-native listeners can achieve native-like performance for speech perception tasks in quiet, the presence of a background noise is much more detrimental to speech intelligibility for non-native compared to native listeners. Even when performance is equated across groups, it is likely that greater listening effort is required for non-native listeners. Importantly, the added listening effort might result in increased fatigue and a reduced ability to successfully perform multiple tasks simultaneously. Task-evoked pupil responses have been demonstrated to be a reliable measure of cognitive effort and can be useful in clarifying those aspects. In this study we compared the pupil response for 23 native English speakers and 27 Italian speakers of English as a second language. Speech intelligibility was tested for sentences presented in quiet and in background noise at two performance levels that were matched across groups. Signal-to-noise levels corresponding to these sentence intelligibility levels were pre-determined using an adaptive intelligibility task. Pupil response was significantly greater in non-native compared to native participants across both intelligibility levels. Therefore, for a given intelligibility level, a greater listening effort is required when listening in a second language in order to understand speech in noise. Results also confirmed that pupil response is sensitive to speech intelligibility during language comprehension, in line with previous research. However, contrary to our predictions, pupil response was not differentially modulated by intelligibility levels for native and non-native listeners. The present study corroborates that pupillometry can be deemed as a valid measure to be used in speech perception investigation, because it is sensitive to differences both across participants, such as listener type, and across conditions, such as variations in the level of speech intelligibility. Importantly, pupillometry offers us the possibility to uncover differences in listening effort even when those do not emerge in the performance level of individuals. PMID:29593489

  16. Monetary rewards modulate inhibitory control

    PubMed Central

    Herrera, Paula M.; Speranza, Mario; Hampshire, Adam; Bekinschtein, Tristán A.

    2014-01-01

    The ability to override a dominant response, often referred to as behavioral inhibition, is considered a key element of executive cognition. Poor behavioral inhibition is a defining characteristic of several neurological and psychiatric populations. Recently, there has been increasing interest in the motivational dimension of behavioral inhibition, with some experiments incorporating emotional contingencies in classical inhibitory paradigms such as the Go/NoGo and Stop Signal Tasks (SSTs). Several studies have reported a positive modulatory effect of reward on performance in pathological conditions such as substance abuse, pathological gambling, and Attention Deficit Hyperactive Disorder (ADHD). However, experiments that directly investigate the modulatory effects of reward magnitudes on the performance of inhibitory tasks are scarce and little is known about the finer grained relationship between motivation and inhibitory control. Here we probed the effect of reward magnitude and context on behavioral inhibition with three modified versions of the widely used SST. The pilot study compared inhibition performance during six blocks alternating neutral feedback, low, medium, and high monetary rewards. Study One compared increasing vs. decreasing rewards, with low, high rewards, and neutral feedback; whilst Study Two compared low and high reward magnitudes alone also in an increasing and decreasing reward design. The reward magnitude effect was not demonstrated in the pilot study, probably due to a learning effect induced by practice in this lengthy task. The reward effect per se was weak but the context (order of reward) was clearly suggested in Study One, and was particularly strongly confirmed in study two. In addition, these findings revealed a “kick start effect” over global performance measures. Specifically, there was a long lasting improvement in performance throughout the task when participants received the highest reward magnitudes at the beginning of the protocol. These results demonstrate a dynamical behavioral inhibition capacity in humans, as illustrated by the reward magnitude modulation and initial reward history effects. PMID:24860469

  17. Estimating Ocean Currents from Automatic Identification System Based Ship Drift Measurements

    NASA Astrophysics Data System (ADS)

    Jakub, Thomas D.

    Ship drift is a technique that has been used over the last century and a half to estimate ocean currents. Several of the shortcomings of the ship drift technique include obtaining the data from multiple ships, the time delay in getting those ship positions to a data center for processing and the limited resolution based on the amount of time between position measurements. These shortcomings can be overcome through the use of the Automatic Identification System (AIS). AIS enables more precise ocean current estimates, the option of finer resolution and more timely estimates. In this work, a demonstration of the use of AIS to compute ocean currents is performed. A corresponding error and sensitivity analysis is performed to help identify under which conditions errors will be smaller. A case study in San Francisco Bay with constant AIS message updates was compared against high frequency radar and demonstrated ocean current magnitude residuals of 19 cm/s for ship tracks in a high signal to noise environment. These ship tracks were only minutes long compared to the normally 12 to 24 hour ship tracks. The Gulf of Mexico case study demonstrated the ability to estimate ocean currents over longer baselines and identified the dependency of the estimates on the accuracy of time measurements. Ultimately, AIS measurements when combined with ship drift can provide another method of estimating ocean currents, particularly when other measurements techniques are not available.

  18. Faster protein folding using enhanced conformational sampling of molecular dynamics simulation.

    PubMed

    Kamberaj, Hiqmet

    2018-05-01

    In this study, we applied swarm particle-like molecular dynamics (SPMD) approach to enhance conformational sampling of replica exchange simulations. In particular, the approach showed significant improvement in sampling efficiency of conformational phase space when combined with replica exchange method (REM) in computer simulation of peptide/protein folding. First we introduce the augmented dynamical system of equations, and demonstrate the stability of the algorithm. Then, we illustrate the approach by using different fully atomistic and coarse-grained model systems, comparing them with the standard replica exchange method. In addition, we applied SPMD simulation to calculate the time correlation functions of the transitions in a two dimensional surface to demonstrate the enhancement of transition path sampling. Our results showed that folded structure can be obtained in a shorter simulation time using the new method when compared with non-augmented dynamical system. Typically, in less than 0.5 ns using replica exchange runs assuming that native folded structure is known and within simulation time scale of 40 ns in the case of blind structure prediction. Furthermore, the root mean square deviations from the reference structures were less than 2Å. To demonstrate the performance of new method, we also implemented three simulation protocols using CHARMM software. Comparisons are also performed with standard targeted molecular dynamics simulation method. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Modeling Real-Time Coordination of Distributed Expertise and Event Response in NASA Mission Control Center Operations

    NASA Astrophysics Data System (ADS)

    Onken, Jeffrey

    This dissertation introduces a multidisciplinary framework for the enabling of future research and analysis of alternatives for control centers for real-time operations of safety-critical systems. The multidisciplinary framework integrates functional and computational models that describe the dynamics in fundamental concepts of previously disparate engineering and psychology research disciplines, such as group performance and processes, supervisory control, situation awareness, events and delays, and expertise. The application in this dissertation is the real-time operations within the NASA Mission Control Center in Houston, TX. This dissertation operationalizes the framework into a model and simulation, which simulates the functional and computational models in the framework according to user-configured scenarios for a NASA human-spaceflight mission. The model and simulation generates data according to the effectiveness of the mission-control team in supporting the completion of mission objectives and detecting, isolating, and recovering from anomalies. Accompanying the multidisciplinary framework is a proof of concept, which demonstrates the feasibility of such a framework. The proof of concept demonstrates that variability occurs where expected based on the models. The proof of concept also demonstrates that the data generated from the model and simulation is useful for analyzing and comparing MCC configuration alternatives because an investigator can give a diverse set of scenarios to the simulation and the output compared in detail to inform decisions about the effect of MCC configurations on mission operations performance.

  20. Mathematical abilities in dyslexic children: a diffusion tensor imaging study.

    PubMed

    Koerte, Inga K; Willems, Anna; Muehlmann, Marc; Moll, Kristina; Cornell, Sonia; Pixner, Silvia; Steffinger, Denise; Keeser, Daniel; Heinen, Florian; Kubicki, Marek; Shenton, Martha E; Ertl-Wagner, Birgit; Schulte-Körne, Gerd

    2016-09-01

    Dyslexia is characterized by a deficit in language processing which mainly affects word decoding and spelling skills. In addition, children with dyslexia also show problems in mathematics. However, for the latter, the underlying structural correlates have not been investigated. Sixteen children with dyslexia (mean age 9.8 years [0.39]) and 24 typically developing children (mean age 9.9 years [0.29]) group matched for age, gender, IQ, and handedness underwent 3 T MR diffusion tensor imaging as well as cognitive testing. Tract-Based Spatial Statistics were performed to correlate behavioral data with diffusion data. Children with dyslexia performed worse than controls in standardized verbal number tasks, such as arithmetic efficiency tests (addition, subtraction, multiplication, division). In contrast, the two groups did not differ in the nonverbal number line task. Arithmetic efficiency, representing the total score of the four arithmetic tasks, multiplication, and division, correlated with diffusion measures in widespread areas of the white matter, including bilateral superior and inferior longitudinal fasciculi in children with dyslexia compared to controls. Children with dyslexia demonstrated lower performance in verbal number tasks but performed similarly to controls in a nonverbal number task. Further, an association between verbal arithmetic efficiency and diffusion measures was demonstrated in widespread areas of the white matter suggesting compensatory mechanisms in children with dyslexia compared to controls. Taken together, poor fact retrieval in children with dyslexia is likely a consequence of deficits in the language system, which not only affects literacy skills but also impacts on arithmetic skills.

  1. The impact of constructive feedback on training in gastrointestinal endoscopy using high-fidelity Virtual-Reality simulation: a randomised controlled trial.

    PubMed

    Kruglikova, Irina; Grantcharov, Teodor P; Drewes, Asbjorn M; Funch-Jensen, Peter

    2010-02-01

    Recently, virtual reality computer simulators have been used to enhance traditional endoscopy teaching. Previous studies have demonstrated construct validity of these systems and transfer of virtual skills to the operating room. However, to date no simulator-training curricula have been designed and there is very little evidence on the impact of external feedback on acquisition of endoscopic skills. The aim of the present study was to assess the impact of external feedback on the learning curves on a VR colonoscopy simulator using inexperienced trainees. 22 trainees, without colonoscopy experience were randomised to a group which received structured feedback provided by an experienced supervisor and a controlled group. All participants performed 15 repetitions of task 3 from the Introduction colonoscopy module of the Accu Touch Endoscopy simulator. Retention/transfer tests on simulator were performed 4-6 weeks after the last repetition. The proficiency levels were based on the performance of eight experienced colonoscopists. All subjects were able to complete the procedure on the simulator. There were no perforations in the feedback group versus seven in the non-feedback group. Subjects in the feedback group reached expert proficiency levels in percentage of mucosa visualised and time to reach the caecum significantly faster compared with the control group. None of the groups demonstrated significant degradation of performance in simulator retention/transfer tests. Concurrent feedback given by supervisor concur an advantage in acquisition of basic colonoscopy skills and achieving of proficiency level as compared to independent training.

  2. Effects of Different Resistance Training Frequencies on Fat in Overweight/Obese Older Women.

    PubMed

    Cavalcante, Edilaine F; Ribeiro, Alex S; do Nascimento, Matheus A; Silva, Analiza M; Tomeleri, Crisieli M; Nabuco, Hellen C G; Pina, Fábio L C; Mayhew, Jerry L; Da Silva-Grigoletto, Marzo E; da Silva, Danilo R P; Fleck, Steven J; Cyrino, Edilson S

    2018-05-18

    This study compared the effect of different resistance training (RT) frequencies on total, android, gynoid and trunk body fat in overweight/obese older women. Fifty-seven overweight/obese older women (66.9±5.3 years and 39.9±4.9% body fat) were randomly assigned to one of three groups: a group performing RT twice a week (G2X), a group performing RT three times a week (G3X), or a non-exercise control group (CG). Both training groups performed the same 12-week RT program consisting of 8 exercises that trained all major muscle groups. Dual-energy X-ray absorptiometry was used to assess body composition. After the intervention period, both G2X and G3X demonstrated significant (P<0.05) reductions in adiposity compared to the CG for total body fat (G2X=-1.7%, G3X=-2.7%, CG=+2.1%), android fat (G2X=-6.2%, G3X=-7.0%, CG=+8.6%), gynoid fat (G2X=-2.5%, G3X=-2.9%, CG=+1.0%), and trunk fat (G2X=-2.5%, G3X=-3.0%, CG=+2.9%), with no significant differences between training groups. These results demonstrate that a low-volume 12-week RT program performed two or three times per week causes decreases in total and regional fat deposition with the greatest reductions occurring in the android region. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Pushing the Performance Limit of Sub-100 nm Molybdenum Disulfide Transistors.

    PubMed

    Liu, Yuan; Guo, Jian; Wu, Yecun; Zhu, Enbo; Weiss, Nathan O; He, Qiyuan; Wu, Hao; Cheng, Hung-Chieh; Xu, Yang; Shakir, Imran; Huang, Yu; Duan, Xiangfeng

    2016-10-12

    Two-dimensional semiconductors (2DSCs) such as molybdenum disulfide (MoS 2 ) have attracted intense interest as an alternative electronic material in the postsilicon era. However, the ON-current density achieved in 2DSC transistors to date is considerably lower than that of silicon devices, and it remains an open question whether 2DSC transistors can offer competitive performance. A high current device requires simultaneous minimization of the contact resistance and channel length, which is a nontrivial challenge for atomically thin 2DSCs, since the typical low contact resistance approaches for 2DSCs either degrade the electronic properties of the channel or are incompatible with the fabrication process for short channel devices. Here, we report a new approach toward high-performance MoS 2 transistors by using a physically assembled nanowire as a lift-off mask to create ultrashort channel devices with pristine MoS 2 channel and self-aligned low resistance metal/graphene hybrid contact. With the optimized contact in short channel devices, we demonstrate sub-100 nm MoS 2 transistor delivering a record high ON-current of 0.83 mA/μm at 300 K and 1.48 mA/μm at 20 K, which compares well with that of silicon devices. Our study, for the first time, demonstrates that the 2DSC transistors can offer comparable performance to the 2017 target for silicon transistors in International Technology Roadmap for Semiconductors (ITRS), marking an important milestone in 2DSC electronics.

  4. NDARC - NASA Design and Analysis of Rotorcraft Validation and Demonstration

    NASA Technical Reports Server (NTRS)

    Johnson, Wayne

    2010-01-01

    Validation and demonstration results from the development of the conceptual design tool NDARC (NASA Design and Analysis of Rotorcraft) are presented. The principal tasks of NDARC are to design a rotorcraft to satisfy specified design conditions and missions, and then analyze the performance of the aircraft for a set of off-design missions and point operating conditions. The aircraft chosen as NDARC development test cases are the UH-60A single main-rotor and tail-rotor helicopter, the CH-47D tandem helicopter, the XH-59A coaxial lift-offset helicopter, and the XV-15 tiltrotor. These aircraft were selected because flight performance data, a weight statement, detailed geometry information, and a correlated comprehensive analysis model are available for each. Validation consists of developing the NDARC models for these aircraft by using geometry and weight information, airframe wind tunnel test data, engine decks, rotor performance tests, and comprehensive analysis results; and then comparing the NDARC results for aircraft and component performance with flight test data. Based on the calibrated models, the capability of the code to size rotorcraft is explored.

  5. Predicting microRNA-disease associations using label propagation based on linear neighborhood similarity.

    PubMed

    Li, Guanghui; Luo, Jiawei; Xiao, Qiu; Liang, Cheng; Ding, Pingjian

    2018-05-12

    Interactions between microRNAs (miRNAs) and diseases can yield important information for uncovering novel prognostic markers. Since experimental determination of disease-miRNA associations is time-consuming and costly, attention has been given to designing efficient and robust computational techniques for identifying undiscovered interactions. In this study, we present a label propagation model with linear neighborhood similarity, called LPLNS, to predict unobserved miRNA-disease associations. Additionally, a preprocessing step is performed to derive new interaction likelihood profiles that will contribute to the prediction since new miRNAs and diseases lack known associations. Our results demonstrate that the LPLNS model based on the known disease-miRNA associations could achieve impressive performance with an AUC of 0.9034. Furthermore, we observed that the LPLNS model based on new interaction likelihood profiles could improve the performance to an AUC of 0.9127. This was better than other comparable methods. In addition, case studies also demonstrated our method's outstanding performance for inferring undiscovered interactions between miRNAs and diseases, especially for novel diseases. Copyright © 2018. Published by Elsevier Inc.

  6. Robust Control for The G-Limit Microgravity Vibration Isolation System

    NASA Technical Reports Server (NTRS)

    Whorton, Mark S.

    2004-01-01

    Many microgravity science experiments need an active isolation system to provide a sufficiently quiescent acceleration environment. The g-LIMIT vibration isolation system will provide isolation for Microgravity Science Glovebox experiments in the International Space Station. While standard control system technologies have been demonstrated for these applications, modern control methods have the potential for meeting performance requirements while providing robust stability in the presence of parametric uncertainties that are characteristic of microgravity vibration isolation systems. While H2 and H infinity methods are well established, neither provides the levels of attenuation performance and robust stability in a compensator with low order. Mixed H2/mu controllers provide a means for maximizing robust stability for a given level of mean-square nominal performance while directly optimizing for controller order constraints. This paper demonstrates the benefit of mixed norm design from the perspective of robustness to parametric uncertainties and controller order for microgravity vibration isolation. A nominal performance metric analogous to the mu measure for robust stability assessment is also introduced in order to define an acceptable trade space from which different control methodologies can be compared.

  7. TCP Packet Trace Analysis. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Shepard, Timothy J.

    1991-01-01

    Examination of a trace of packets collected from the network is often the only method available for diagnosing protocol performance problems in computer networks. This thesis explores the use of packet traces to diagnose performance problems of the transport protocol TCP. Unfortunately, manual examination of these traces can be so tedious that effective analysis is not possible. The primary contribution of this thesis is a graphical method of displaying the packet trace which greatly reduce, the tediousness of examining a packet trace. The graphical method is demonstrated by the examination of some packet traces of typical TCP connections. The performance of two different implementations of TCP sending data across a particular network path is compared. Traces many thousands of packets long are used to demonstrate how effectively the graphical method simplifies examination of long complicated traces. In the comparison of the two TCP implementations, the burstiness of the TCP transmitter appeared to be related to the achieved throughput. A method of quantifying this burstiness is presented and its possible relevance to understanding the performance of TCP is discussed.

  8. Inlet Trade Study for a Low-Boom Aircraft Demonstrator

    NASA Technical Reports Server (NTRS)

    Heath, Christopher M.; Slater, John W.; Rallabhandi, Sriram K.

    2016-01-01

    Propulsion integration for low-boom supersonic aircraft requires careful inlet selection, placement, and tailoring to achieve acceptable propulsive and aerodynamic performance, without compromising vehicle sonic boom loudness levels. In this investigation, an inward-turning streamline-traced and axisymmetric spike inlet are designed and independently installed on a conceptual low-boom supersonic demonstrator aircraft. The airframe was pre-shaped to achieve a target ground under-track loudness of 76.4 PLdB at cruise using an adjoint-based design optimization process. Aircraft and inlet performance characteristics were obtained by solution of the steady-state Reynolds-averaged Navier-Stokes equations. Isolated cruise inlet performance including total pressure recovery and distortion were computed and compared against installed inlet performance metrics. Evaluation of vehicle near-field pressure signatures, along with under- and off-track propagated loudness levels is also reported. Results indicate the integrated axisymmetric spike design offers higher inlet pressure recovery, lower fan distortion, and reduced sonic boom. The vehicle with streamline-traced inlet exhibits lower external wave drag, which translates to a higher lift-to-drag ratio and increased range capability.

  9. Field Evaluation of Medium-Duty Plug-in Electric Delivery Trucks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prohaska, Robert; Simpson, Mike; Ragatz, Adam

    2016-12-01

    This report focuses on medium-duty electric delivery vehicles operated by Frito-Lay North America (FLNA) at its Federal Way, Washington, distribution center. The 100% electric drive system is an alternative to conventional diesel delivery trucks and reduces both energy consumption and carbon dioxide (CO2) emissions. The vehicles' drive cycles and operation are analyzed and compared to demonstrate the importance of matching specific electric vehicle (EV) technologies to the appropriate operational duty cycle. The results of this analysis show that the Smith Newton EVs demonstrated a 68% reduction in energy consumption over the data reporting period compared to the conventional diesel vehicles,more » as well as a 46.4% reduction in CO 2 equivalent emissions based on the local energy generation source. In addition to characterizing the in-use performance of the EVs compared to the conventional diesels, detailed facility load data were collected at the main building power feed as well as from each of the 10 EV chargers to better understand the broader implications associated with commercial EV deployment. These facility loads were incorporated into several modeling scenarios to demonstrate the potential benefits of integrating onsite renewables.« less

  10. Silk-polypyrrole biocompatible actuator performance under biologically relevant conditions

    NASA Astrophysics Data System (ADS)

    Hagler, Jo'elen; Peterson, Ben; Murphy, Amanda; Leger, Janelle

    Biocompatible actuators that are capable of controlled movement and can function under biologically relevant conditions are of significant interest in biomedical fields. Previously, we have demonstrated that a composite material of silk biopolymer and the conducting polymer polypyrrole (PPy) can be formed into a bilayer device that can bend under applied voltage. Further, these silk-PPy composites can generate forces comparable to human muscle (>0.1 MPa) making them ideal candidates for interfacing with biological tissues. Here silk-PPy composite films are tested for performance under biologically relevant conditions including exposure to a complex protein serum and biologically relevant temperatures. Free-end bending actuation performance, current response, force generation and, mass degradation were investigated . Preliminary results show that when exposed to proteins and biologically relevant temperatures, these silk-PPy composites show minimal degradation and are able to generate forces and conduct currents comparable to devices tested under standard conditions. NSF.

  11. Verbal fluency in bilingual Spanish/English Alzheimer's disease patients.

    PubMed

    Salvatierra, Judy; Rosselli, Monica; Acevedo, Amarilis; Duara, Ranjan

    2007-01-01

    Studies have demonstrated that in verbal fluency tests, monolinguals with Alzheimer's disease (AD) show greater difficulties retrieving words based on semantic rather than phonemic rules. The present study aimed to determine whether this difficulty was reproduced in both languages of Spanish/English bilinguals with mild to moderate AD whose primary language was Spanish. Performance on semantic and phonemic verbal fluency of 11 bilingual AD patients was compared to the performance of 11 cognitively normal, elderly bilingual individuals matched for gender, age, level of education, and degree of bilingualism. Cognitively normal subjects retrieved significantly more items under the semantic condition compared to the phonemic, whereas the performance of AD patients was similar under both conditions, suggesting greater decline in semantic verbal fluency tests. This pattern was produced in both languages, implying a related semantic decline in both languages. Results from this study should be considered preliminary because of the small sample size.

  12. Changes in Cortical Activity During Real and Imagined Movements: an ERP Study

    PubMed Central

    Machado, Sergio; Arias-Carrión, Oscar; Paes, Flávia; Ribeiro, Pedro; Cagy, Mauricio; Piedade, Roberto; Almada, Leonardo Ferreira; Anghinah, Renato; Basile, Luis; Moro, Maria Francesca; Orsini, Marco; Silva, Julio Guilherme; Silva, Adriana Cardoso; Nardi, Antonio E.

    2013-01-01

    This study aims to compare the topographic distribution of cortical activation between real and imagined movement through event-related potential (ERP). We are specifically interested in identifying, the topographic distribution of activated areas, the intensity of activated areas, and the temporal occurrence of these activations on preparation and motor response phases. Twelve healthy and right handed subjects were instructed to perform a task under real and imagery conditions. The task was performed simultaneously to electroencephalographic (EEG) recording. When compared the conditions, we found a statistically significant difference in favor of real condition revealed by performing an unpaired t-test with multiple corrections of Bonferroni, demonstrating negative activity on electrode C3 and positive activity on the electrode C4 only in motor response phase. These findings revealed similar functional connections established during real and imagery conditions, suggesting that there are common neural substrate and similar properties of functional integration shared by conditions. PMID:24358049

  13. Changes in Cortical Activity During Real and Imagined Movements: an ERP Study.

    PubMed

    Machado, Sergio; Arias-Carrión, Oscar; Paes, Flávia; Ribeiro, Pedro; Cagy, Mauricio; Piedade, Roberto; Almada, Leonardo Ferreira; Anghinah, Renato; Basile, Luis; Moro, Maria Francesca; Orsini, Marco; Silva, Julio Guilherme; Silva, Adriana Cardoso; Nardi, Antonio E

    2013-11-15

    This study aims to compare the topographic distribution of cortical activation between real and imagined movement through event-related potential (ERP). We are specifically interested in identifying, the topographic distribution of activated areas, the intensity of activated areas, and the temporal occurrence of these activations on preparation and motor response phases. Twelve healthy and right handed subjects were instructed to perform a task under real and imagery conditions. The task was performed simultaneously to electroencephalographic (EEG) recording. When compared the conditions, we found a statistically significant difference in favor of real condition revealed by performing an unpaired t-test with multiple corrections of Bonferroni, demonstrating negative activity on electrode C3 and positive activity on the electrode C4 only in motor response phase. These findings revealed similar functional connections established during real and imagery conditions, suggesting that there are common neural substrate and similar properties of functional integration shared by conditions.

  14. A superior edge preserving filter with a systematic analysis

    NASA Technical Reports Server (NTRS)

    Holladay, Kenneth W.; Rickman, Doug

    1991-01-01

    A new, adaptive, edge preserving filter for use in image processing is presented. It had superior performance when compared to other filters. Termed the contiguous K-average, it aggregates pixels by examining all pixels contiguous to an existing cluster and adding the pixel closest to the mean of the existing cluster. The process is iterated until K pixels were accumulated. Rather than simply compare the visual results of processing with this operator to other filters, some approaches were developed which allow quantitative evaluation of how well and filter performs. Particular attention is given to the standard deviation of noise within a feature and the stability of imagery under iterative processing. Demonstrations illustrate the performance of several filters to discriminate against noise and retain edges, the effect of filtering as a preprocessing step, and the utility of the contiguous K-average filter when used with remote sensing data.

  15. Miniaturisation of Pressure-Sensitive Paint Measurement Systems Using Low-Cost, Miniaturised Machine Vision Cameras.

    PubMed

    Quinn, Mark Kenneth; Spinosa, Emanuele; Roberts, David A

    2017-07-25

    Measurements of pressure-sensitive paint (PSP) have been performed using new or non-scientific imaging technology based on machine vision tools. Machine vision camera systems are typically used for automated inspection or process monitoring. Such devices offer the benefits of lower cost and reduced size compared with typically scientific-grade cameras; however, their optical qualities and suitability have yet to be determined. This research intends to show relevant imaging characteristics and also show the applicability of such imaging technology for PSP. Details of camera performance are benchmarked and compared to standard scientific imaging equipment and subsequent PSP tests are conducted using a static calibration chamber. The findings demonstrate that machine vision technology can be used for PSP measurements, opening up the possibility of performing measurements on-board small-scale model such as those used for wind tunnel testing or measurements in confined spaces with limited optical access.

  16. Inner speech impairments in autism.

    PubMed

    Whitehouse, Andrew J O; Maybery, Murray T; Durkin, Kevin

    2006-08-01

    Three experiments investigated the role of inner speech deficit in cognitive performances of children with autism. Experiment 1 compared children with autism with ability-matched controls on a verbal recall task presenting pictures and words. Experiment 2 used pictures for which the typical names were either single syllable or multisyllable. Two encoding conditions manipulated the use of verbal encoding. Experiment 3 employed a task-switching paradigm for which performance has been shown to be contingent upon inner speech. In Experiment 1, children with autism demonstrated a lower picture-superiority effect compared to controls. In Experiment 2, the children with autism showed a lower word-length effect when pictures were presented alone, but a more substantial word-length effect in a condition requiring overt labelling. In Experiment 3, articulatory suppression affected the task-switching performance of the control participants only. Individuals with autism have limitations in their use of inner speech.

  17. Performance and diversity of polyvinyl alcohol-degrading bacteria under aerobic and anaerobic conditions.

    PubMed

    Huang, Jianping; Yang, Shisu; Zhang, Siqi

    2016-11-01

    To compare the degradation performance and biodiversity of a polyvinyl alcohol-degrading microbial community under aerobic and anaerobic conditions. An anaerobic-aerobic bioreactor was operated to degrade polyvinyl alcohol (PVA) in simulated wastewater. The degradation performance of the bioreactor during sludge cultivation and the microbial communities in each reactor were compared. Both anaerobic and aerobic bioreactors demonstrated high chemical oxygen demand removal efficiencies of 87.5 and 83.6 %, respectively. Results of 16S rDNA sequencing indicated that Proteobacteria dominated in both reactors and that the microbial community structures varied significantly under different operating conditions. Both reactors obviously differed in bacterial diversity from the phyla Planctomycetes, Chlamydiae, Bacteroidetes, and Chloroflexi. Betaproteobacteria and Alphaproteobacteria dominated, respectively, in the anaerobic and aerobic reactors. The anaerobic-aerobic system is suitable for PVA wastewater treatment, and the microbial genetic analysis may serve as a reference for PVA biodegradation.

  18. Miniaturisation of Pressure-Sensitive Paint Measurement Systems Using Low-Cost, Miniaturised Machine Vision Cameras

    PubMed Central

    Spinosa, Emanuele; Roberts, David A.

    2017-01-01

    Measurements of pressure-sensitive paint (PSP) have been performed using new or non-scientific imaging technology based on machine vision tools. Machine vision camera systems are typically used for automated inspection or process monitoring. Such devices offer the benefits of lower cost and reduced size compared with typically scientific-grade cameras; however, their optical qualities and suitability have yet to be determined. This research intends to show relevant imaging characteristics and also show the applicability of such imaging technology for PSP. Details of camera performance are benchmarked and compared to standard scientific imaging equipment and subsequent PSP tests are conducted using a static calibration chamber. The findings demonstrate that machine vision technology can be used for PSP measurements, opening up the possibility of performing measurements on-board small-scale model such as those used for wind tunnel testing or measurements in confined spaces with limited optical access. PMID:28757553

  19. Comparing an FPGA to a Cell for an Image Processing Application

    NASA Astrophysics Data System (ADS)

    Rakvic, Ryan N.; Ngo, Hau; Broussard, Randy P.; Ives, Robert W.

    2010-12-01

    Modern advancements in configurable hardware, most notably Field-Programmable Gate Arrays (FPGAs), have provided an exciting opportunity to discover the parallel nature of modern image processing algorithms. On the other hand, PlayStation3 (PS3) game consoles contain a multicore heterogeneous processor known as the Cell, which is designed to perform complex image processing algorithms at a high performance. In this research project, our aim is to study the differences in performance of a modern image processing algorithm on these two hardware platforms. In particular, Iris Recognition Systems have recently become an attractive identification method because of their extremely high accuracy. Iris matching, a repeatedly executed portion of a modern iris recognition algorithm, is parallelized on an FPGA system and a Cell processor. We demonstrate a 2.5 times speedup of the parallelized algorithm on the FPGA system when compared to a Cell processor-based version.

  20. Estimating A Reference Standard Segmentation With Spatially Varying Performance Parameters: Local MAP STAPLE

    PubMed Central

    Commowick, Olivier; Akhondi-Asl, Alireza; Warfield, Simon K.

    2012-01-01

    We present a new algorithm, called local MAP STAPLE, to estimate from a set of multi-label segmentations both a reference standard segmentation and spatially varying performance parameters. It is based on a sliding window technique to estimate the segmentation and the segmentation performance parameters for each input segmentation. In order to allow for optimal fusion from the small amount of data in each local region, and to account for the possibility of labels not being observed in a local region of some (or all) input segmentations, we introduce prior probabilities for the local performance parameters through a new Maximum A Posteriori formulation of STAPLE. Further, we propose an expression to compute confidence intervals in the estimated local performance parameters. We carried out several experiments with local MAP STAPLE to characterize its performance and value for local segmentation evaluation. First, with simulated segmentations with known reference standard segmentation and spatially varying performance, we show that local MAP STAPLE performs better than both STAPLE and majority voting. Then we present evaluations with data sets from clinical applications. These experiments demonstrate that spatial adaptivity in segmentation performance is an important property to capture. We compared the local MAP STAPLE segmentations to STAPLE, and to previously published fusion techniques and demonstrate the superiority of local MAP STAPLE over other state-of-the- art algorithms. PMID:22562727

  1. Biomechanical Comparison of Single- Versus Double-Row Capsulolabral Repair for Shoulder Instability: A Review

    PubMed Central

    Yousif, Matthew John; Bicos, James

    2017-01-01

    Background: The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. Purpose: To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Study Design: Narrative review. Methods: A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Results: Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. Conclusion: The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed. PMID:29230427

  2. Somatic, Endurance Performance and Heart Rate Variability Profiles of Professional Soccer Players Grouped According to Age

    PubMed Central

    Botek, Michal; McKune, Andrew J.; Klimešová, Iva

    2016-01-01

    Abstract This cross-sectional study compared somatic, endurance performance determinants and heart rate variability (HRV) profiles of professional soccer players divided into different age groups: GI (17–19.9 years; n = 23), GII (20–24.9 years; n = 45), GIII (25–29.9 years; n = 30), and GIV (30–39 years; n = 26). Players underwent somatic and HRV assessment and maximal exercise testing. HRV was analyzed by spectral analysis of HRV, and high (HF) and low (LF) frequency power was transformed by a natural logarithm (Ln). Players in GIV (83 ± 7 kg) were heavier (p < 0.05) compared to both GI (73 ± 6 kg), and GII (78 ± 6 kg). Significantly lower maximal oxygen uptake (VO2max, ml•kg-1•min-1) was observed for GIV (56.6 ± 3.8) compared to GI (59.6 ± 3.9), GII (59.4 ± 4.2) and GIV (59.7 ± 4.1). All agegroups, except for GII, demonstrated comparable relative maximal power output (Pmax). For supine HRV, significantly lower Ln HF (ms2) was identified in both GIII (7.1 ± 0.8) and GIV (6.9 ± 1.0) compared to GI (7.9 ± 0.6) and GII (7.7 ± 0.9). In conclusion, soccer players aged >25 years showed negligible differences in Pmax unlike the age group differences demonstrated in VO2max. A shift towards relative sympathetic dominance, particularly due to reduced vagal activity, was apparent after approximately 8 years of competing at the professional level. PMID:28031758

  3. Differences in Cognitive Processes Underlying the Collaborative Activities of Children and Chimpanzees

    ERIC Educational Resources Information Center

    Fletcher, Grace E.; Warneken, Felix; Tomasello, Michael

    2012-01-01

    We compared the performance of 3- and 5-year-old children with that of chimpanzees in two tasks requiring collaboration via complementary roles. In both tasks, children and chimpanzees were able to coordinate two complementary roles with peers and solve the problem cooperatively. This is the first experimental demonstration of the coordination of…

  4. Symbolic Estrangement: Evidence against a Strong Association between Numerical Symbols and the Quantities They Represent

    ERIC Educational Resources Information Center

    Lyons, Ian M.; Ansari, Daniel; Beilock, Sian L.

    2012-01-01

    Are numerals estranged from a sense of the actual quantities they represent? We demonstrate that, irrespective of numerical size or distance, direct comparison of the relative quantities represented by symbolic and nonsymbolic formats leads to performance markedly worse than when comparing 2 nonsymbolic quantities (Experiment 1). Experiment 2…

  5. Beating the Odds: Finding Schools Exceeding Achievement Expectations with High-Risk Students. Summary. REL 2014-032

    ERIC Educational Resources Information Center

    Koon, Sharon; Petscher, Yaacov; Foorman, Barbara R.

    2014-01-01

    State education leaders are often interested in identifying schools that have demonstrated success with improving the literacy of students who are at the highest level of risk for reading difficulties. The identification of these schools that are "beating the odds" is typically accomplished by comparing a school's observed performance on…

  6. Beating the Odds: Finding Schools Exceeding Achievement Expectations with High-Risk Students. REL 2014-032

    ERIC Educational Resources Information Center

    Koon, Sharon; Petscher, Yaacov; Foorman, Barbara R.

    2014-01-01

    State education leaders are often interested in identifying schools that have demonstrated success with improving the literacy of students who are at the highest level of risk for reading difficulties. The identification of these schools that are "beating the odds" is typically accomplished by comparing a school's observed performance on…

  7. Benefits of Interhemispheric Collaboration Can Be Eliminated by Mixing Stimulus Formats that Involve Different Cortical Access Routes

    ERIC Educational Resources Information Center

    Patel, Urvi J.; Hellige, Joseph B.

    2007-01-01

    Previous studies indicate that the benefits of dividing an information processing load across both cerebral hemispheres outweigh the costs of interhemispheric transfer as tasks become more difficult or cognitively complex. This is demonstrated as better performance when two stimuli to be compared are presented one to each visual field and…

  8. Do We See through Their Eyes? Testing a Bilingual Questionnaire in Education Research Using Cognitive Interviews

    ERIC Educational Resources Information Center

    Sopromadze, Natia; Moorosi, Pontso

    2017-01-01

    The paper aims to demonstrate the value of cognitive interviewing (CI) as a survey pretesting method in comparative education research. Although rarely used by education researchers, CI has been successfully applied in different disciplines to evaluate and improve question performance. The method assumes that observing people's thought processes…

  9. Internet over a Bi-Directional Satellite Link

    NASA Technical Reports Server (NTRS)

    Griner, Jim; Allman, Mark; Mallasch, Paul; Stewart, David

    1998-01-01

    Various issues associated with "Internet over a Bi-Directional Satellite Link" are presented in viewgraph form. Specific topics include: 1) Comarison of HTTP over several network channels; 2) Improved performance of HTTP when compared to off-the-shelf software; 3) Demonstration setup of the link between Sheraton Airport Hotel, Dulles and NASA LeRC; and 4) HTTP comparison pages.

  10. Development of low cost fabrication techniques for large solid rocket nozzles

    NASA Technical Reports Server (NTRS)

    Warga, J. J.

    1971-01-01

    Property measurements and fabrication characteristics were determined and the performance in subscale (Minuteman Wing 2 second stage) motors was evaluated. It was demonstrated that the incorporation of low cost fabrication techniques in a full scale 260 in. nozzle could result in savings of $149,000 when compared with an identical design using tape-wrapped components throughout.

  11. The Effects of Socio-Economic Status on Prospective English Language Teachers' Academic Achievement

    ERIC Educational Resources Information Center

    Koban Koç, Didem

    2016-01-01

    Socioeconomic status (SES), which generally involves factors such as parental educational background, occupation and income level, is a strong predictor of student achievement. That is, students with higher parental SES demonstrate increased academic performance when compared to those with lower parental SES. The purpose of the present study is to…

  12. Translators and Interpreters Certification in Australia, Canada, the USA and Ukraine: Comparative Analysis

    ERIC Educational Resources Information Center

    Skyba, Kateryna

    2014-01-01

    The article presents an overview of the certification process by which potential translators and interpreters demonstrate minimum standards of performance to warrant official or professional recognition of their ability to translate or interpret and to practice professionally in Australia, Canada, the USA and Ukraine. The aim of the study is to…

  13. Factors influencing physical and technical variability in the English Premier League.

    PubMed

    Bush, Michael D; Archer, David T; Hogg, Robert; Bradley, Paul S

    2015-10-01

    To investigate match-to-match variability of physical and technical performances in English Premier League players and quantify the influence of positional and contextual factors. Match data (N = 451) were collected using a multicamera computerized tracking system across multiple seasons (2005-06 to 2012-13). The coefficient of variation (CV) was calculated from match to match for physical and technical performances in selected positions across different match contexts (location, standard, and result). Wide midfielders demonstrated the greatest CVs for total distance (4.9% ± 5.9%) and central midfielders the smallest (3.6% ± 2.0%); nevertheless, all positions exhibited CVs <5% (P > .05, effect size [ES] 0.1-0.3). Central defenders demonstrated the greatest CVs and wide midfielders the lowest for both high-intensity running (20.2% ± 8.8% and 13.7% ± 7.7%, P < .05, ES 0.4-0.8) and sprint distance (32.3% ± 13.8% and 22.6% ± 11.2%, P < .05, ES 0.5-0.8). Technical indicators such as tackles (83.7% ± 42.3%), possessions won (47.2% ± 27.9%), and interceptions (59.1% ± 37.3%) illustrated substantial variability for attackers compared with all other positions (P < .05, ES 0.4-1.1). Central defenders demonstrated large variability for the number of times tackled per match (144.9% ± 58.3%) and passes attempted and received compared with other positions (39.2% ± 17.5% and 46.9% ± 20.2%, P < .001, ES 0.6-1.8). Contextual factors had limited impact on the variability of physical and technical parameters. The data demonstrate that technical parameters varied more from match to match than physical parameters. Defensive players (fullbacks and central defenders) displayed higher CVs for offensive technical variables, while attacking players (attackers and wide midfielders) exhibited higher CVs for defensive technical variables. Physical and technical performances are variable per se regardless of context.

  14. Modulating Thin Film Transistor Characteristics by Texturing the Gate Metal.

    PubMed

    Nair, Aswathi; Bhattacharya, Prasenjit; Sambandan, Sanjiv

    2017-12-20

    The development of reliable, high performance integrated circuits based on thin film transistors (TFTs) is of interest for the development of flexible electronic circuits. In this work we illustrate the modulation of TFT transconductance via the texturing of the gate metal created by the addition of a conductive pattern on top of a planar gate. Texturing results in the semiconductor-insulator interface acquiring a non-planar geometry with local variations in the radius of curvature. This influences various TFT parameters such as the subthreshold slope, gate voltage at the onset of conduction, contact resistance and gate capacitance. Specific studies are performed on textures based on periodic striations oriented along different directions. Textured TFTs showed upto ±40% variation in transconductance depending on the texture orientation as compared to conventional planar gate TFTs. Analytical models are developed and compared with experiments. Gain boosting in common source amplifiers based on textured TFTs as compared to conventional TFTs is demonstrated.

  15. Early Rehabilitation in Elderly after Arthroplasty versus Internal Fixation for Unstable Intertrochanteric Fractures of Femur: Systematic Review and Meta-Analysis.

    PubMed

    Yoo, Jun Il; Ha, Yong Chan; Lim, Jae Young; Kang, Hyun; Yoon, Byung Ho; Kim, Hyunho

    2017-05-01

    The purpose of this study was to compare the outcomes focusing on the functional outcome and clinical results of replacement arthroplasty (AP) vs. internal fixation (IF) for the treatment of unstable intertrochanteric femoral fracture in elderly. Systematic review and meta-analysis were performed on 10 available clinical studies (2 randomized controlled trials and 8 comparative studies). Subgroup analysis was performed by type of methodological quality. Partial weight bearing time in AP group was earlier than that in IF group (SMD = -0.86; 95% CI = -0.42, 1.29; P = 0.050). The overall outcomes such as mortality, reoperation rate, and complication showed no significant diffrence between the 2 groups (AP vs. IF). Therefore, this systematic review demonstrates that AP provides superior functional outcomes especially earlier mobilization, as compared to IF in elderly patients with an unstable intertrochanteric femoral fracture. © 2017 The Korean Academy of Medical Sciences.

  16. US and Turkish preschoolers' observational knowledge of astronomy

    NASA Astrophysics Data System (ADS)

    Saçkes, Mesut; McCormick Smith, Mandy; Cabe Trundle, Kathy

    2016-01-01

    The purpose of this cross-cultural study was to describe and compare US and Turkish children's observational knowledge of the day and night cycle and to identify similarities predicted by framework theory. Fifty-six (27 US and 29 Turkish) young children (ages 48-60 months) participated in the study. Semi-structured interviews were individually conducted, digitally recorded, transcribed, and analyzed using the constant comparative method. The results demonstrate that preschoolers from the two cultures are able to make comparable informal observations of the sky, and their observational knowledge includes many similarities, with one exception, as predicted by framework theory. US children were more likely to perform better than the Turkish children on the question about the time of observation for the moon. Although science concepts and skills are better represented in US early childhood education programs than the Turkish program, the results suggest that this advantage did not translate into performance differences between US and Turkish children.

  17. Photometric and colorimetric measurements of CRT and TFT monitors for vision research

    NASA Astrophysics Data System (ADS)

    Klein, Johann; Zlatkova, Margarita; Lauritzen, Jan; Pierscionek, Barbara

    2013-08-01

    Visual displays have various limitations that can affect the results of vision research experiments. This study compares several characteristics of CRT (Hewlett Packard 7650) and TFT (LG Flatron L227 WT and Samsung 2233 RZ) monitors, including luminance and colour spatial homogeneity, luminance changes with viewing angle, contrast linearity and warm-up characteristics. In addition, the psychophysical performance in grating contrast sensitivity test for both CRT and TFT monitors was compared. The TFT monitors demonstrated spatial non-homogeneity ('mura') with up to 50% of luminance change across the screen and a more significant luminance viewing angle dependence compared with CRT. The chromaticity of the white point showed negligible variation across the screen. Both types of monitors required a warm-up time of the order of 60 min. Despite the physical differences between monitors, visual contrast sensitivity performance measured with the two types of monitors was similar using both static and flickering gratings.

  18. [Improving speech comprehension using a new cochlear implant speech processor].

    PubMed

    Müller-Deile, J; Kortmann, T; Hoppe, U; Hessel, H; Morsnowski, A

    2009-06-01

    The aim of this multicenter clinical field study was to assess the benefits of the new Freedom 24 sound processor for cochlear implant (CI) users implanted with the Nucleus 24 cochlear implant system. The study included 48 postlingually profoundly deaf experienced CI users who demonstrated speech comprehension performance with their current speech processor on the Oldenburg sentence test (OLSA) in quiet conditions of at least 80% correct scores and who were able to perform adaptive speech threshold testing using the OLSA in noisy conditions. Following baseline measures of speech comprehension performance with their current speech processor, subjects were upgraded to the Freedom 24 speech processor. After a take-home trial period of at least 2 weeks, subject performance was evaluated by measuring the speech reception threshold with the Freiburg multisyllabic word test and speech intelligibility with the Freiburg monosyllabic word test at 50 dB and 70 dB in the sound field. The results demonstrated highly significant benefits for speech comprehension with the new speech processor. Significant benefits for speech comprehension were also demonstrated with the new speech processor when tested in competing background noise.In contrast, use of the Abbreviated Profile of Hearing Aid Benefit (APHAB) did not prove to be a suitably sensitive assessment tool for comparative subjective self-assessment of hearing benefits with each processor. Use of the preprocessing algorithm known as adaptive dynamic range optimization (ADRO) in the Freedom 24 led to additional improvements over the standard upgrade map for speech comprehension in quiet and showed equivalent performance in noise. Through use of the preprocessing beam-forming algorithm BEAM, subjects demonstrated a highly significant improved signal-to-noise ratio for speech comprehension thresholds (i.e., signal-to-noise ratio for 50% speech comprehension scores) when tested with an adaptive procedure using the Oldenburg sentences in the clinical setting S(0)N(CI), with speech signal at 0 degrees and noise lateral to the CI at 90 degrees . With the convincing findings from our evaluations of this multicenter study cohort, a trial with the Freedom 24 sound processor for all suitable CI users is recommended. For evaluating the benefits of a new processor, the comparative assessment paradigm used in our study design would be considered ideal for use with individual patients.

  19. In vitro Reactivity to Implant Metals Demonstrates a Person Dependent Association with both T-Cell and B-Cell Activation

    PubMed Central

    Hallab, Nadim James; Caicedo, Marco; Epstein, Rachael; McAllister, Kyron; Jacobs, Joshua J

    2009-01-01

    Hypersensitivity to metallic implants remains relatively unpredictable and poorly understood. We initially hypothesized that metal-induced lymphocyte proliferation responses to soluble metal challenge (ions) are mediated exclusively by early T-cell activation (not B-cells), typical of a Delayed-Type-Hypersensitivity response. We tested this by comparing proliferation (6-days) of primary lymphocytes with early T-cell and B-cell activation (48-hours) in three groups of subjects likely to demonstrate elevated metal-reactivity: Group 1(n=12) history of metal-sensitivity with no implant; Group 2a(n=6) well performing metal-on-metal THRs, and Group 2b(n=20) subjects with poorly performing metal-on-polymer total joint arthroplasties (TJA). Group 1 showed 100%(12/12) metal reactivity (Stimulation Index>2) to Ni. Group 2a&2b were 83%(5/6) and 75%(15/22) metal reactive (to Co, Cr or Ni) respectively. Of the n=32 metal reactive subjects to Co, Cr or Ni (SI>2), n=22/32 demonstrated >2-fold elevations in % of T-cell or B-cell activation (CD25+,CD69+) to metal challenge compared to untreated control. 18/22 metal-activated subjects demonstrated an exclusively T-cell or B-cell activation response to metal challenge, where 6/18 demonstrated exclusively B-cell activation and 12/18 demonstrated a T-cell only response, as measured by surface activation markers CD25+ and CD69+. However, there was no direct correlation (R2<0.1) between lymphocyte proliferation and % T-cell or B-cell activation (CD25+:CD69+). Proliferation assays (LTT) showed greater ability to detect metal reactivity than did subject-dependent results of flow-cytometry analysis of T-cell or B-cell activation. The high incidence of lymphocyte reactivity and activation, indicate that more complex than initially hypothesized immune responses may contribute to the etiology of debris induced osteolysis in metal-sensitive individuals. PMID:19235773

  20. Reynolds-Averaged Navier-Stokes Simulation of a 2D Circulation Control Wind Tunnel Experiment

    NASA Technical Reports Server (NTRS)

    Allan, Brian G.; Jones, Greg; Lin, John C.

    2011-01-01

    Numerical simulations are performed using a Reynolds-averaged Navier-Stokes (RANS) flow solver for a circulation control airfoil. 2D and 3D simulation results are compared to a circulation control wind tunnel test conducted at the NASA Langley Basic Aerodynamics Research Tunnel (BART). The RANS simulations are compared to a low blowing case with a jet momentum coefficient, C(sub u), of 0:047 and a higher blowing case of 0.115. Three dimensional simulations of the model and tunnel walls show wall effects on the lift and airfoil surface pressures. These wall effects include a 4% decrease of the midspan sectional lift for the C(sub u) 0.115 blowing condition. Simulations comparing the performance of the Spalart Allmaras (SA) and Shear Stress Transport (SST) turbulence models are also made, showing the SST model compares best to the experimental data. A Rotational/Curvature Correction (RCC) to the turbulence model is also evaluated demonstrating an improvement in the CFD predictions.

Top