Sample records for demonstrated excellent correlation

  1. Performance of PROMIS Instruments in Patients With Shoulder Instability.

    PubMed

    Anthony, Chris A; Glass, Natalie A; Hancock, Kyle; Bollier, Matt; Wolf, Brian R; Hettrich, Carolyn M

    2017-02-01

    Shoulder instability is a relatively common condition occurring in 2% of the population. PROMIS (Patient-Reported Outcome Measurement Information System) was developed by the National Institutes of Health in an effort to advance patient-reported outcome (PRO) instruments by developing question banks for major health domains. To compare PROMIS instruments to current PRO instruments in patients who would be undergoing operative intervention for recurrent shoulder instability. Cohort study (diagnosis); Level of evidence, 2. A total of 74 patients with a primary diagnosis of shoulder instability who would be undergoing surgery were asked to fill out the American Shoulder and Elbow Surgeons shoulder assessment form (ASES), Marx shoulder activity scale (Marx), Short Form-36 Health Survey Physical Function subscale (SF-36 PF), Western Ontario Shoulder Instability Index (WOSI), PROMIS physical function computer adaptive test (PF CAT), and PROMIS upper extremity item bank (UE). Correlation between PRO instruments was defined as excellent (>0.7), excellent-good (0.61-0.7), good (0.4-0.6), and poor (0.2-0.3). Utilization of the PROMIS UE demonstrated excellent correlation with the SF-36 PF ( r = 0.78, P < .01) and ASES ( r = 0.71, P < .01); there was excellent-good correlation with the EQ-5D ( r = 0.66, P < .01), WOSI ( r = 0.63, P < .01), and PROMIS PF CAT ( r = 0.63, P < .01). Utilization of the PROMIS PF CAT demonstrated excellent correlation with the SF-36 PF ( r = 0.72, P < .01); there was excellent-good correlation with the ASES ( r = 0.67, P < .01) and PROMIS UE ( r = 0.63, P < .01). When utilizing the PROMIS UE, ceiling effects were present in 28.6% of patients aged 18 to 21 years. Patients, on average, answered 4.6 ± 1.8 questions utilizing the PROMIS PF CAT. The PROMIS UE and PROMIS PF CAT demonstrated good to excellent correlation with common shoulder and upper extremity PRO instruments as well as the SF-36 PF in patients with shoulder instability. In patients aged ≤21 years, there were significant ceiling effects utilizing the PROMIS UE. While the PROMIS PF CAT appears appropriate for use in adults of any age, our findings demonstrate that the PROMIS UE has significant ceiling effects in patients with shoulder instability who are ≤21 years old, and we do not recommend use of the PROMIS UE in this population.

  2. Automated Radiology-Pathology Module Correlation Using a Novel Report Matching Algorithm by Organ System.

    PubMed

    Dane, Bari; Doshi, Ankur; Gfytopoulos, Soterios; Bhattacharji, Priya; Recht, Michael; Moore, William

    2018-05-01

    Radiology-pathology correlation is time-consuming and is not feasible in most clinical settings, with the notable exception of breast imaging. The purpose of this study was to determine if an automated radiology-pathology report pairing system could accurately match radiology and pathology reports, thus creating a feedback loop allowing for more frequent and timely radiology-pathology correlation. An experienced radiologist created a matching matrix of radiology and pathology reports. These matching rules were then exported to a novel comprehensive radiology-pathology module. All distinct radiology-pathology pairings at our institution from January 1, 2016 to July 1, 2016 were included (n = 8999). The appropriateness of each radiology-pathology report pairing was scored as either "correlative" or "non-correlative." Pathology reports relating to anatomy imaged in the specific imaging study were deemed correlative, whereas pathology reports describing anatomy not imaged with the particular study were denoted non-correlative. Overall, there was 88.3% correlation (accuracy) of the radiology and pathology reports (n = 8999). Subset analysis demonstrated that computed tomography (CT) abdomen/pelvis, CT head/neck/face, CT chest, musculoskeletal CT (excluding spine), mammography, magnetic resonance imaging (MRI) abdomen/pelvis, MRI brain, musculoskeletal MRI (excluding spine), breast MRI, positron emission tomography (PET), breast ultrasound, and head/neck ultrasound all demonstrated greater than 91% correlation. When further stratified by imaging modality, CT, MRI, mammography, and PET demonstrated excellent correlation (greater than 96.3%). Ultrasound and non-PET nuclear medicine studies demonstrated poorer correlation (80%). There is excellent correlation of radiology imaging reports and appropriate pathology reports when matched by organ system. Rapid, appropriate radiology-pathology report pairings provide an excellent opportunity to close feedback loop to the interpreting radiologist. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Development and validation of a patient-reported outcome measure in vitiligo: The Self Assessment Vitiligo Extent Score (SA-VES).

    PubMed

    van Geel, Nanja; Lommerts, Janny E; Bekkenk, Marcel W; Prinsen, Cecilia A C; Eleftheriadou, Viktoria; Taieb, Alain; Picardo, Mauro; Ezzedine, Khaled; Wolkerstorfer, Albert; Speeckaert, Reinhart

    2017-03-01

    The Vitiligo Extent Score (VES) has recently been introduced as a physicians' score for the clinical assessment of the extent of vitiligo, but a good patient self-assessment score is lacking. The objective is to develop and validate a simplified version of the VES as a patient-reported outcome measure (PROM). After extensive pilot testing, patients were asked to score their vitiligo extent twice with an interval of 2 weeks using the Self Assessment Vitiligo Extent Score (SA-VES). The scores were compared with the physicians' evaluation (VES). The SA-VES demonstrated very good test-retest reliability (intraclass correlation = 0.948, 95% confidence interval [CI]: 0.911-0.970) that was not affected by age, skin type, or vitiligo distribution pattern. According to patients, this evaluation method was easy to use (22% very easy; 49% easy; 29% normal) and required <5 minutes in the majority of patients (73%, <5 minutes; 24%, 5-10 minutes; 2%, 10-15 minutes). Comparison of the SA-VES and the VES demonstrated excellent correlation (r = 0.986, P <.001). Few patients had a dark skin type. The results demonstrate excellent reliability of the SA-VES and excellent correlation with its investigator-reported counterpart (VES). This patient-oriented evaluation method provides a useful tool for the assessment of vitiligo extent. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  4. The sizing of hamstring grafts for anterior cruciate reconstruction: intra- and inter-observer reliability.

    PubMed

    Dwyer, Tim; Whelan, Daniel B; Khoshbin, Amir; Wasserstein, David; Dold, Andrew; Chahal, Jaskarndip; Nauth, Aaron; Murnaghan, M Lucas; Ogilvie-Harris, Darrell J; Theodoropoulos, John S

    2015-04-01

    The objective of this study was to establish the intra- and inter-observer reliability of hamstring graft measurement using cylindrical sizing tubes. Hamstring tendons (gracilis and semitendinosus) were harvested from ten cadavers by a single surgeon and whip stitched together to create ten 4-strand hamstring grafts. Ten sports medicine surgeons and fellows sized each graft independently using either hollow cylindrical sizers or block sizers in 0.5-mm increments—the sizing technique used was applied consistently to each graft. Surgeons moved sequentially from graft to graft and measured each hamstring graft twice. Surgeons were asked to state the measured proximal (femoral) and distal (tibial) diameter of each graft, as well as the diameter of the tibial and femoral tunnels that they would drill if performing an anterior cruciate ligament (ACL) reconstruction using that graft. Reliability was established using intra-class correlation coefficients. Overall, both the inter-observer and intra-observer agreement were >0.9, demonstrating excellent reliability. The inter-observer reliability for drill sizes was also excellent (>0.9). Excellent correlation was seen between cylindrical sizing, and drill sizes (>0.9). Sizing of hamstring grafts by multiple surgeons demonstrated excellent intra-observer and intra-observer reliability, potentially validating clinical studies exploring ACL reconstruction outcomes by hamstring graft diameter when standard techniques are used. III.

  5. The origin of excellent gate-bias stress stability in organic field-effect transistors employing fluorinated-polymer gate dielectrics.

    PubMed

    Kim, Jiye; Jang, Jaeyoung; Kim, Kyunghun; Kim, Haekyoung; Kim, Se Hyun; Park, Chan Eon

    2014-11-12

    Tuning of the energetic barriers to charge transfer at the semiconductor/dielectric interface in organic field-effect transistors (OFETs) is achieved by varying the dielectric functionality. Based on this, the correlation between the magnitude of the energy barrier and the gate-bias stress stability of the OFETs is demonstrated, and the origin of the excellent device stability of OFETs employing fluorinated dielectrics is revealed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS)

    PubMed Central

    2013-01-01

    Background Streetscape (microscale) features of the built environment can influence people’s perceptions of their neighborhoods’ suitability for physical activity. Many microscale audit tools have been developed, but few have published systematic scoring methods. We present the development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS) tool and its theoretically-based subscales. Methods MAPS was based on prior instruments and was developed to assess details of streetscapes considered relevant for physical activity. MAPS sections (route, segments, crossings, and cul-de-sacs) were scored by two independent raters for reliability analyses. There were 290 route pairs, 516 segment pairs, 319 crossing pairs, and 53 cul-de-sac pairs in the reliability sample. Individual inter-rater item reliability analyses were computed using Kappa, intra-class correlation coefficient (ICC), and percent agreement. A conceptual framework for subscale creation was developed using theory, expert consensus, and policy relevance. Items were grouped into subscales, and subscales were analyzed for inter-rater reliability at tiered levels of aggregation. Results There were 160 items included in the subscales (out of 201 items total). Of those included in the subscales, 80 items (50.0%) had good/excellent reliability, 41 items (25.6%) had moderate reliability, and 18 items (11.3%) had low reliability, with limited variability in the remaining 21 items (13.1%). Seventeen of the 20 route section subscales, valence (positive/negative) scores, and overall scores (85.0%) demonstrated good/excellent reliability and 3 demonstrated moderate reliability. Of the 16 segment subscales, valence scores, and overall scores, 12 (75.0%) demonstrated good/excellent reliability, three demonstrated moderate reliability, and one demonstrated poor reliability. Of the 8 crossing subscales, valence scores, and overall scores, 6 (75.0%) demonstrated good/excellent reliability, and 2 demonstrated moderate reliability. The cul-de-sac subscale demonstrated good/excellent reliability. Conclusions MAPS items and subscales predominantly demonstrated moderate to excellent reliability. The subscales and scoring system represent a theoretically based framework for using these complex microscale data and may be applicable to other similar instruments. PMID:23621947

  7. Development and Validation of a Portable and Inexpensive Tool to Measure the Drop Vertical Jump Using the Microsoft Kinect V2.

    PubMed

    Gray, Aaron D; Willis, Brad W; Skubic, Marjorie; Huo, Zhiyu; Razu, Swithin; Sherman, Seth L; Guess, Trent M; Jahandar, Amirhossein; Gulbrandsen, Trevor R; Miller, Scott; Siesener, Nathan J

    Noncontact anterior cruciate ligament (ACL) injury in adolescent female athletes is an increasing problem. The knee-ankle separation ratio (KASR), calculated at initial contact (IC) and peak flexion (PF) during the drop vertical jump (DVJ), is a measure of dynamic knee valgus. The Microsoft Kinect V2 has shown promise as a reliable and valid marker-less motion capture device. The Kinect V2 will demonstrate good to excellent correlation between KASR results at IC and PF during the DVJ, as compared with a "gold standard" Vicon motion analysis system. Descriptive laboratory study. Level 2. Thirty-eight healthy volunteer subjects (20 male, 18 female) performed 5 DVJ trials, simultaneously measured by a Vicon MX-T40S system, 2 AMTI force platforms, and a Kinect V2 with customized software. A total of 190 jumps were completed. The KASR was calculated at IC and PF during the DVJ. The intraclass correlation coefficient (ICC) assessed the degree of KASR agreement between the Kinect and Vicon systems. The ICCs of the Kinect V2 and Vicon KASR at IC and PF were 0.84 and 0.95, respectively, showing excellent agreement between the 2 measures. The Kinect V2 successfully identified the KASR at PF and IC frames in 182 of 190 trials, demonstrating 95.8% reliability. The Kinect V2 demonstrated excellent ICC of the KASR at IC and PF during the DVJ when compared with the Vicon system. A customized Kinect V2 software program demonstrated good reliability in identifying the KASR at IC and PF during the DVJ. Reliable, valid, inexpensive, and efficient screening tools may improve the accessibility of motion analysis assessment of adolescent female athletes.

  8. Correlation and registration of ERTS multispectral imagery. [by a digital processing technique

    NASA Technical Reports Server (NTRS)

    Bonrud, L. O.; Henrikson, P. J.

    1974-01-01

    Examples of automatic digital processing demonstrate the feasibility of registering one ERTS multispectral scanner (MSS) image with another obtained on a subsequent orbit, and automatic matching, correlation, and registration of MSS imagery with aerial photography (multisensor correlation) is demonstrated. Excellent correlation was obtained with patch sizes exceeding 16 pixels square. Qualities which lead to effective control point selection are distinctive features, good contrast, and constant feature characteristics. Results of the study indicate that more than 300 degrees of freedom are required to register two standard ERTS-1 MSS frames covering 100 by 100 nautical miles to an accuracy of 0.6 pixel mean radial displacement error. An automatic strip processing technique demonstrates 600 to 1200 degrees of freedom over a quater frame of ERTS imagery. Registration accuracies in the range of 0.3 pixel to 0.5 pixel mean radial error were confirmed by independent error analysis. Accuracies in the range of 0.5 pixel to 1.4 pixel mean radial error were demonstrated by semi-automatic registration over small geographic areas.

  9. A Lifelong Learning Scale for Research and Evaluation of Teaching and Curricular Effectiveness

    ERIC Educational Resources Information Center

    Wielkiewicz, Richard M.; Meuwissen, Alyssa S.

    2014-01-01

    A 16-item lifelong learning scale (LLS), appropriate for college students and others, was evaluated using a sample of 575 college students. The scale demonstrated excellent reliability and was correlated with college grade point average (GPA), agreeableness, conscientiousness, and intellect/imagination. Scores were higher for those who had studied…

  10. Dirac points, spinons and spin liquid in twisted bilayer graphene

    NASA Astrophysics Data System (ADS)

    Irkhin, V. Yu.; Skryabin, Yu. N.

    2018-05-01

    Twisted bilayer graphene is an excellent example of highly correlated system demonstrating a nearly flat electron band, the Mott transition and probably a spin liquid state. Besides the one-electron picture, analysis of Dirac points is performed in terms of spinon Fermi surface in the limit of strong correlations. Application of gauge field theory to describe deconfined spin liquid phase is treated. Topological quantum transitions, including those from small to large Fermi surface in the presence of van Hove singularities, are discussed.

  11. Endoanal MRI of the anal sphincter complex: correlation with cross-sectional anatomy and histology.

    PubMed Central

    Hussain, S M; Stoker, J; Zwamborn, A W; Den Hollander, J C; Kuiper, J W; Entius, C A; Laméris, J S

    1996-01-01

    The purpose of this study was to correlate the in vivo endoanal MRI findings of the anal sphincter with the cross-sectional anatomy and histology. Fourteen patients with rectal tumours were examined with a rigid endoanal MR coil before undergoing abdominoperineal resection. In addition, 12 cadavers were used to obtain cross-sectional anatomical sections. The images were correlated with the histology and anatomy of the resected rectal specimens as well as with the cross-sectional anatomical sections of the 12 cadavers. The findings in 8 patients, 11 rectal preparations, and 10 cadavers, could be compared. In these cases, there was an excellent correlation between endoanal MRI and the cross-sectional cadaver anatomy and histology. With endoanal MRI, all muscle layers of the anal canal wall, comprising the internal anal sphincter, longitudinal muscle, the external anal sphincter and the puborectalis muscle were clearly visible. The levator ani muscle and ligamentous attachments were also well demonstrated. The perianal anatomical spaces, containing multiple septae, were clearly visible. In conclusion, endoanal MRI is excellent for visualising the anal sphincter complex and the findings show a good correlation with the cross-sectional anatomy and histology. Images Fig. 1 Fig. 2 PMID:8982844

  12. Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists.

    PubMed

    Moran, Robert W; Rushworth, Wendy M; Mason, Jesse

    2017-12-01

    Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p < 0.001) demonstrated good convergent validity. There was a medium to large effect (Cohen's d > 0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Orbital-occupancy versus charge ordering and the strength of electron correlations in electron-doped CaMnO3.

    PubMed

    Luo, Weidong; Franceschetti, Alberto; Varela, Maria; Tao, Jing; Pennycook, Stephen J; Pantelides, Sokrates T

    2007-07-20

    The structural, electronic, and magnetic properties of mixed-valence compounds are believed to be governed by strong electron correlations. Here we report benchmark density-functional calculations in the spin-polarized generalized-gradient approximation (GGA) for the ground-state properties of doped CaMnO(3). We find excellent agreement with all available data, while inclusion of strong correlations in the GGA+U scheme impairs this agreement. We demonstrate that formal oxidation states reflect only orbital occupancies, not charge transfer, and resolve outstanding controversies about charge ordering.

  14. Orbital-Occupancy versus Charge Ordering and the Strength of Electron Correlations in Electron-Doped CaMnO3

    NASA Astrophysics Data System (ADS)

    Luo, Weidong; Franceschetti, Alberto; Varela, Maria; Tao, Jing; Pennycook, Stephen J.; Pantelides, Sokrates T.

    2007-07-01

    The structural, electronic, and magnetic properties of mixed-valence compounds are believed to be governed by strong electron correlations. Here we report benchmark density-functional calculations in the spin-polarized generalized-gradient approximation (GGA) for the ground-state properties of doped CaMnO3. We find excellent agreement with all available data, while inclusion of strong correlations in the GGA+U scheme impairs this agreement. We demonstrate that formal oxidation states reflect only orbital occupancies, not charge transfer, and resolve outstanding controversies about charge ordering.

  15. Psychometric validation of a sexual quality of life questionnaire for use in men with premature ejaculation or erectile dysfunction.

    PubMed

    Abraham, Lucy; Symonds, Tara; Morris, Mark F

    2008-03-01

    An instrument that can systematically capture the impact of sexual dysfunction on quality of life (QoL) in men is needed. To psychometrically validate a sexual QoL instrument for men (SQOL-M) with premature ejaculation (PE) or erectile dysfunction (ED). The main assessment populations were men participating in clinical trials of treatments for PE or ED. Men with PE had a confirmed intravaginal ejaculatory latency time of < or = 2 minutes in > or = 70% of attempts. Men with ED had a score of > 21 on the International Index of Erectile Function (IIEF). Confirmatory psychometric testing was conducted in further groups of men with PE. The internal consistency, convergent and discriminant validity, test-retest reliability, and known-groups validity of the instrument were assessed. An 11-item version of the SQOL-M was produced following factor analyses on men with either PE or ED. Psychometric testing showed no overlap between items and good item-total correlations. Factor analysis confirmed a one-factor solution. Excellent internal consistency was demonstrated, with a Cronbach's alpha of > or = 0.82 in all groups. In men reporting no change in their symptoms, the SQOL-M showed excellent test-retest reliability: the intraclass correlation coefficient was 0.77 for men with PE, and 0.79 for men with ED. Convergent validity was also good. In men with PE, the SQOL-M correlated with the satisfaction and distress domains of the Index of Premature Ejaculation. In men with ED, the SQOL-M correlated with the overall satisfaction domain of the IIEF. The measure also demonstrated excellent discriminant validity between men with PE or ED and men with no sexual dysfunction (P < 0.0001). The SQOL-M instrument is a useful tool for evaluating sexual QoL in men with PE and ED.

  16. Correlation and Reliability of Cervical Sagittal Alignment Parameters between Lateral Cervical Radiograph and Lateral Whole-Body EOS Stereoradiograph.

    PubMed

    Singhatanadgige, Weerasak; Kang, Daniel G; Luksanapruksa, Panya; Peters, Colleen; Riew, K Daniel

    2016-09-01

    Retrospective analysis. To evaluate the correlation and reliability of cervical sagittal alignment parameters obtained from lateral cervical radiographs (XRs) compared with lateral whole-body stereoradiographs (SRs). We evaluated adults with cervical deformity using both lateral XRs and lateral SRs obtained within 1 week of each other between 2010 and 2014. XR and SR images were measured by two independent spine surgeons using the following sagittal alignment parameters: C2-C7 sagittal Cobb angle (SCA), C2-C7 sagittal vertical axis (SVA), C1-C7 translational distance (C1-7), T1 slope (T1-S), neck tilt (NT), and thoracic inlet angle (TIA). Pearson correlation and paired t test were used for statistical analysis, with intra- and interrater reliability analyzed using intraclass correlation coefficient (ICC). A total of 35 patients were included in the study. We found excellent intrarater reliability for all sagittal alignment parameters in both the XR and SR groups with ICC ranging from 0.799 to 0.994 for XR and 0.791 to 0.995 for SR. Interrater reliability was also excellent for all parameters except NT and TIA, which had fair reliability. We also found excellent correlations between XR and SR measurements for most sagittal alignment parameters; SCA, SVA, and C1-C7 had r > 0.90, and only NT had r < 0.70. There was a significant difference between groups, with SR having lower measurements compared with XR for both SVA (0.68 cm lower, p < 0.001) and C1-C7 (1.02 cm lower, p < 0.001). There were no differences between groups for SCA, T1-S, NT, and TIA. Whole-body stereoradiography appears to be a viable alternative for measuring cervical sagittal alignment parameters compared with standard radiography. XR and SR demonstrated excellent correlation for most sagittal alignment parameters except NT. However, SR had significantly lower average SVA and C1-C7 measurements than XR. The lower radiation exposure using single SR has to be weighed against its higher cost compared with XR.

  17. Measurement properties of the Dizziness Handicap Inventory by cross-sectional and longitudinal designs

    PubMed Central

    2009-01-01

    Background The impact of dizziness on quality of life is often assessed by the Dizziness Handicap Inventory (DHI), which is used as a discriminate and evaluative measure. The aim of the present study was to examine reliability and validity of a translated Norwegian version (DHI-N), also examining responsiveness to important change in the construct being measured. Methods Two samples (n = 92 and n = 27) included participants with dizziness of mainly vestibular origin. A cross-sectional design was used to examine the factor structure (exploratory factor analysis), internal consistency (Cronbach's α), concurrent validity (Pearson's product moment correlation r), and discriminate ability (ROC curve analysis). Longitudinal designs were used to examine test-retest reliability (intraclass correlation coefficient (ICC) statistics, smallest detectable difference (SDD)), and responsiveness (Pearson's product moment correlation, ROC curve analysis; area under the ROC curve (AUC), and minimally important change (MIC)). The DHI scores range from 0 to 100. Results Factor analysis revealed a different factor structure than the original DHI, resulting in dismissal of subscale scores in the DHI-N. Acceptable internal consistency was found for the total scale (α = 0.95). Concurrent correlations between the DHI-N and other related measures were moderate to high, highest with Vertigo Symptom Scale-short form-Norwegian version (r = 0.69), and lowest with preferred gait (r = - 0.36). The DHI-N demonstrated excellent ability to discriminate between participants with and without 'disability', AUC being 0.89 and best cut-off point = 29 points. Satisfactory test-retest reliability was demonstrated, and the change for an individual should be ≥ 20 DHI-N points to exceed measurement error (SDD). Correlations between change scores of DHI-N and other self-report measures of functional health and symptoms were high (r = 0.50 - 0.57). Responsiveness of the DHI-N was excellent, AUC = 0.83, discriminating between self-perceived 'improved' versus 'unchanged' participants. The MIC was identified as 11 DHI-N points. Conclusions The DHI-N total scale demonstrated satisfactory measurement properties. This is the first study that has addressed and demonstrated responsiveness to important change of the DHI, and provided values of SDD and MIC to help interpret change scores. PMID:20025754

  18. Coding stimulus amplitude by correlated neural activity

    NASA Astrophysics Data System (ADS)

    Metzen, Michael G.; Ávila-Åkerberg, Oscar; Chacron, Maurice J.

    2015-04-01

    While correlated activity is observed ubiquitously in the brain, its role in neural coding has remained controversial. Recent experimental results have demonstrated that correlated but not single-neuron activity can encode the detailed time course of the instantaneous amplitude (i.e., envelope) of a stimulus. These have furthermore demonstrated that such coding required and was optimal for a nonzero level of neural variability. However, a theoretical understanding of these results is still lacking. Here we provide a comprehensive theoretical framework explaining these experimental findings. Specifically, we use linear response theory to derive an expression relating the correlation coefficient to the instantaneous stimulus amplitude, which takes into account key single-neuron properties such as firing rate and variability as quantified by the coefficient of variation. The theoretical prediction was in excellent agreement with numerical simulations of various integrate-and-fire type neuron models for various parameter values. Further, we demonstrate a form of stochastic resonance as optimal coding of stimulus variance by correlated activity occurs for a nonzero value of noise intensity. Thus, our results provide a theoretical explanation of the phenomenon by which correlated but not single-neuron activity can code for stimulus amplitude and how key single-neuron properties such as firing rate and variability influence such coding. Correlation coding by correlated but not single-neuron activity is thus predicted to be a ubiquitous feature of sensory processing for neurons responding to weak input.

  19. Assessment of reliability, validity, responsiveness and minimally important change of the German Hip dysfunction and osteoarthritis outcome score (HOOS) in patients with osteoarthritis of the hip.

    PubMed

    Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar

    2017-12-01

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.

  20. WASP (Write a Scientific Paper) using Excel - 13: Correlation and Regression.

    PubMed

    Grech, Victor

    2018-07-01

    Correlation and regression measure the closeness of association between two continuous variables. This paper explains how to perform these tests in Microsoft Excel and their interpretation, as well as how to apply these tests dynamically using Excel's functions. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. 1/f noise: diffusive systems and music

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voss, R.F.

    1975-11-01

    Measurements of the 1/f voltage noise in continuous metal films are reported. At room temperature, samples of pure metals and bismuth (with a carrier density smaller by 10/sup 5/) of similar volume had comparable noise. The results suggest that the noise arises from equilibrium temperature fluctuations modulating the resistance. Spatial correlation of the noise implied that the fluctuations obey a diffusion equation. The empirical inclusion of an explicit 1/f region and appropriate normalization lead to excellent agreement with the measured noise. If the fluctuations are assumed to be spatially correlated, the diffusion equation can yield an extended 1/f region inmore » the power spectrum. The temperature response of a sample to delta and step function power inputs is shown to have the same shape as the autocorrelation function for uncorrelated and correlated temperature fluctuations, respectively. The spectrum obtained from the cosine transform of the measured step function response is in excellent agreement with the measured 1/f voltage noise spectrum. Spatially correlated equilibrium temperature fluctuations are not the dominant source of 1/f noise in semiconductors and metal films. However, the agreement between the low-frequency spectrum of fluctuations in the mean-square Johnson noise voltage and the resistance fluctuation spectrum measured in the presence of a current demonstrates that in these systems the 1/f noise is also due to equilibrium resistance fluctuations. Loudness fluctuations in music and speech and pitch fluctuations in music also show the 1/f behavior. 1/f noise sources, consequently, are demonstrated to be the natural choice for stochastic composition. 26 figures, 1 table. (auth)« less

  2. Reliability of the Balance Evaluation Systems Test (BESTest) and BESTest sections for adults with hemiparesis

    PubMed Central

    Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.

    2014-01-01

    BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281

  3. Electric vehicle chassis dynamometer test methods at JPL and their correlation to track tests

    NASA Technical Reports Server (NTRS)

    Marte, J.; Bryant, J.

    1983-01-01

    Early in its electric vehicle (EV) test program, JPL recognized that EV test procedures were too vague and too loosely defined to permit much meaningful data to be obtained from the testing. Therefore, JPL adopted more stringent test procedures and chose the chassis dynamometer rather than the track as its principal test technique. Through the years, test procedures continued to evolve towards a methodology based on chassis dynamometers which would exhibit good correlation with track testing. Based on comparative dynamometer and track test results on the ETV-1 vehicle, the test methods discussed in this report demonstrate a means by which excellent track-to-dynamometer correlation can be obtained.

  4. Reliability of Neurobehavioral Assessments from Birth to Term Equivalent Age in Preterm and Term Born Infants.

    PubMed

    Eeles, Abbey L; Olsen, Joy E; Walsh, Jennifer M; McInnes, Emma K; Molesworth, Charlotte M L; Cheong, Jeanie L Y; Doyle, Lex W; Spittle, Alicia J

    2017-02-01

    Neurobehavioral assessments provide insight into the functional integrity of the developing brain and help guide early intervention for preterm (<37 weeks' gestation) infants. In the context of shorter hospital stays, clinicians often need to assess preterm infants prior to term equivalent age. Few neurobehavioral assessments used in the preterm period have established interrater reliability. To evaluate the interrater reliability of the Hammersmith Neonatal Neurological Examination (HNNE) and the NICU Network Neurobehavioral Scale (NNNS), when used both preterm and at term (>36 weeks). Thirty-five preterm infants and 11 term controls were recruited. Five assessors double-scored the HNNE and NNNS administered either preterm or at term. A one-way random effects, absolute, single-measures interclass correlation coefficient (ICC) was calculated to determine interrater reliability. Interrater reliability for the HNNE was excellent (ICC > 0.74) for optimality scores, and good (ICC 0.60-0.74) to excellent for subtotal scores, except for 'Tone Patterns' (ICC 0.54). On the NNNS, interrater reliability was predominantly excellent for all items. Interrater agreement was generally excellent at both time points. Overall, the HNNE and NNNS neurobehavioral assessments demonstrated mostly excellent interrater reliability when used prior to term and at term.

  5. [Application of numerical convolution in in vivo/in vitro correlation research].

    PubMed

    Yue, Peng

    2009-01-01

    This paper introduced the conception and principle of in vivo/in vitro correlation (IVIVC) and convolution/deconvolution methods, and elucidated in details the convolution strategy and method for calculating the in vivo absorption performance of the pharmaceutics according to the their pharmacokinetic data in Excel, then put the results forward to IVIVC research. Firstly, the pharmacokinetic data ware fitted by mathematical software to make up the lost points. Secondly, the parameters of the optimal fitted input function were defined by trail-and-error method according to the convolution principle in Excel under the hypothesis that all the input functions fit the Weibull functions. Finally, the IVIVC between in vivo input function and the in vitro dissolution was studied. In the examples, not only the application of this method was demonstrated in details but also its simplicity and effectiveness were proved by comparing with the compartment model method and deconvolution method. It showed to be a powerful tool for IVIVC research.

  6. The inter and intra rater reliability of the Netball Movement Screening Tool.

    PubMed

    Reid, Duncan A; Vanweerd, Rebecca J; Larmer, Peter J; Kingstone, Rachel

    2015-05-01

    To establish the inter- and intra-rater reliability of the Netball Movement Screening Tool, for screening adolescent female netball players. Inter- and intra-rater reliability study. Forty secondary school netball players were recruited to take part in the study. Twenty subjects were screened simultaneously and independently by two raters to ascertain inter-rater agreement. Twenty subjects were scored by rater one on two occasions, separated by a week, to ascertain intra-rater agreement. Inter and intra-rater agreement was assessed utilising the two-way mixed inter class correlation coefficient and weighted kappa statistics. No significant demographic differences were found between the inter and intra-rater groups of subjects. Inter class correlation coefficients' demonstrated excellent inter-rater (two-way mixed inter class correlation coefficients 0.84, standard error of measurement 0.25) and intra-rater (two-way mixed inter class correlation coefficients 0.96, standard error of measurement 0.13) reliability for the overall Netball Movement Screening Tool score and substantial-excellent (two-way mixed inter class correlation coefficients 1.0-0.65) inter-rater and substantial-excellent intra-rater (two-way mixed inter class correlation coefficients 0.96-0.79) reliability for the component scores of the Netball Movement Screening Tool. Kappa statistic showed substantial to poor inter-rater (k=0.75-0.32) and intra-rater (k=0.77-0.27) agreement for individual tests of the NMST. The Netball Movement Screening Tool may be a reliable screening tool for adolescent netball players; however the individual test scores have low reliability. The screening tool can be administered reliably by raters with similar levels of training in the tool but variable clinical experience. On-going research needs to be undertaken to ascertain whether the Netball Movement Screening Tool is a valid tool in ascertaining increased injury risk for netball players. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Reliability, Validity, and Sensitivity to Change Overtime of the Modified Melasma Area and Severity Index Score.

    PubMed

    Abou-Taleb, Doaa A E; Ibrahim, Ahmed K; Youssef, Eman M K; Moubasher, Alaa E A

    2017-02-01

    The new modified Melasma Area and Severity Index (mMASI) score, the recently used outcome measure for melasma, has not been tested to determine its sensitivity to change in melasma. To determine the reliability, validity, and sensitivity to change overtime of the mMASI score in assessment of the severity of melasma. Pearson correlation, Cronbach alpha, and intraclass correlation coefficient were calculated to assess the reliability of the mMASI score. Validity of the mMASI scale was carried out using Spearman correlation between mMASI total score (before and after treatment), clinical data, and patient's responses. The mMASI score showed excellent reliability and good validity for assessment of the severity of melasma. The authors also determined that the mMASI score demonstrated sensitivity to change over time. An excellent degree of agreement between the mMSAI and MASI scores was revealed. The mMASI score is reliable, valid, and responsive to change in the assessment of severity of melasma. Moreover, the mMASI score was found to be easier to learn and perform and simpler in calculation compared with the MASI score. Overall, the mMASI score can effectively replace the MASI score.

  8. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: I. Principles and some general algorithms.

    PubMed

    Langenbucher, Frieder

    2002-01-01

    Most computations in the field of in vitro/in vivo correlations can be handled directly by Excel worksheets, without the need for specialized software. Following a summary of Excel features, applications are illustrated for numerical computation of AUC and Mean, Wagner-Nelson and Loo-Riegelman absorption plots, and polyexponential curve fitting.

  9. Validation of the Social Exercise and Anxiety Measure (SEAM): Assessing fears, avoidance, and importance of social exercise

    PubMed Central

    Levinson, Cheri A.; Rodebaugh, Thomas L.; Menatti, Andrew R.; Weeks, Justin W.

    2012-01-01

    In two studies (N = 416; N = 118) examining responses from undergraduates, we developed the Social Exercise and Anxiety Measure (SEAM) and tested its factorial, convergent, and divergent validity. Our results demonstrate that the SEAM exhibits an excellent three factor structure consisting of the following subscales: Social Exercise Self-efficacy, Gym Avoidance, and Exercise Importance. In both studies, Social Exercise Self-efficacy correlated negatively and Gym Avoidance correlated positively with social interaction anxiety, fear of scrutiny, and fear of negative evaluation. Exercise Importance correlated positively with frequency of exercise and frequency of public exercise. Implications for the mental and physical health of individuals with high levels of social anxiety are discussed. PMID:24244069

  10. [SLEEP OF ELITE YOUNG ATHLETE AT THE ACADEMY FOR SPORT EXCELLENCE AT THE WINGATE INSTITUTE].

    PubMed

    Navot Mintzer, Dalya; Shargal, Eyal; Fuxman, Yair; Wissblat, Dorit; Baharav, Anda

    2016-06-01

    Sleep duration and quality have a critical role in cognitive and athletic performances. A relationship was demonstrated between sleep deprivation, reduced performance and elevated injury risk. The recommended sleep duration for teenagers is at least 9 hours a day but most sleep less. To estimate sleep duration among elite adolescent athletes at the Academy for Sport Excellence at the Wingate Institute, by quantifying the changes after joining the academy and the relation to school performances and the usage of medical services. Data from medical records, including sleep screening questionnaires and a number of the athletes' medical appointments were analyzed. Athletes reported that sleep duration was less than recommended before joining the academy. After joining the academy the average sleep duration decreased (7.37 vs 7.7 hours, P = 0.05) and daytime sleepiness was elevated (13/24 v 11/24 Epworth-Sleepiness-Scale (ESS), P = 0.002). Correlations between changes in sleep duration and changes in school achievements before and after joining the academy were demonstrated (P = 0.027). No correlation was found between sleep duration at the academy and usage of medical services. Elite adolescent athletes do not sleep enough and are tired during the day. Reduction in sleep duration and elevation in sleepiness were observed with the transition to practice, study and life at the Academy for Sport Excellence. In accordance with previous studies, our findings showed elite young athletes are in a state of continuous sleep deprivation that interferes with their school achievements. Further research is needed to evaluate the importance of sleep duration and quality in performance for the health of young athletes.

  11. Measurement Properties of the Lower Extremity Functional Scale: A Systematic Review.

    PubMed

    Mehta, Saurabh P; Fulton, Allison; Quach, Cedric; Thistle, Megan; Toledo, Cesar; Evans, Neil A

    2016-03-01

    Systematic review of measurement properties. Many primary studies have examined the measurement properties, such as reliability, validity, and sensitivity to change, of the Lower Extremity Functional Scale (LEFS) in different clinical populations. A systematic review summarizing these properties for the LEFS may provide an important resource. To locate and synthesize evidence on the measurement properties of the LEFS and to discuss the clinical implications of the evidence. A literature search was conducted in 4 databases (PubMed, MEDLINE, Embase, and CINAHL), using predefined search terms. Two reviewers performed a critical appraisal of the included studies using a standardized assessment form. A total of 27 studies were included in the review, of which 18 achieved a very good to excellent methodological quality level. The LEFS scores demonstrated excellent test-retest reliability (intraclass correlation coefficients ranging between 0.85 and 0.99) and demonstrated the expected relationships with measures assessing similar constructs (Pearson correlation coefficient values of greater than 0.7). The responsiveness of the LEFS scores was excellent, as suggested by consistently high effect sizes (greater than 0.8) in patients with different lower extremity conditions. Minimal detectable change at the 90% confidence level (MDC90) for the LEFS scores varied between 8.1 and 15.3 across different reassessment intervals in a wide range of patient populations. The pooled estimate of the MDC90 was 6 points and the minimal clinically important difference was 9 points in patients with lower extremity musculoskeletal conditions, which are indicative of true change and clinically meaningful change, respectively. The results of this review support the reliability, validity, and responsiveness of the LEFS scores for assessing functional impairment in a wide array of patient groups with lower extremity musculoskeletal conditions.

  12. Translation and validation of the Dutch new Knee Society Scoring System ©.

    PubMed

    Van Der Straeten, Catherine; Witvrouw, Erik; Willems, Tine; Bellemans, Johan; Victor, Jan

    2013-11-01

    A new version of The Knee Society Knee Scoring System(©) (KSS) has recently been developed. Before this scale can be used in non-English-speaking populations, it has to be translated and validated for a particular population. We evaluated the construct and content validity, the test-retest reliability, and the internal consistency of the Dutch version of the New Knee Society KSS. A Dutch translation was performed using a forward-backward translation protocol. We tested the construct validity of the Dutch New KSS by comparing it with the Dutch versions of the WOMAC, Knee Injury and Osteoarthritis Outcome Score (KOOS), and SF-12 scores in 137 patients undergoing total knee arthroplasty (TKA). Content validity was assessed by comparing pre- and postoperative scores and by checking floor and ceiling effects. To evaluate test-retest reliability and consistency, 47 patients completed the questionnaire a second time with a mean of 8 days interval (range, 2-20 days) between tests. Construct validity was demonstrated because the Dutch New KSS correlated well with the Dutch WOMAC (r = -0.751; p < 0.001), Dutch KOOS (r = -0.723; p < 0.001), and Dutch SF-12 (r = 0.569; p < 0.001). There was a significant difference between pre- and postoperative scores (p < 0.001) in line with the other scores. Test-retest reliability proved excellent with an intraclass correlation coefficient between 0.73 and 0.92 depending on the domain tested. Consistency as indicated by Cronbach's alpha ranging from 0.84 to 0.96 was good to excellent. As demonstrated by the validation procedure, the Dutch New KSS is an excellent instrument to evaluate TKA outcome in Dutch-speaking patients.

  13. Validity of the stroke rehabilitation assessment of movement scale in acute rehabilitation: a comparison with the functional independence measure and stroke impact scale-16.

    PubMed

    Ward, Irene; Pivko, Susan; Brooks, Gary; Parkin, Kate

    2011-11-01

    To demonstrate sensitivity to change of the Stroke Rehabilitation Assessment of Movement (STREAM) as well as the concurrent and predictive validity of the STREAM in an acute rehabilitation setting. Prospective cohort study. Acute, in-patient rehabilitation department within a tertiary-care teaching hospital in the United States. Thirty adults with a newly diagnosed, first ischemic stroke. Clinical assessments were conducted on admission and then again on discharge from the rehabilitation hospital with the STREAM (total STREAM and upper extremity, lower extremity, and mobility subscales), Functional Independence Measure (FIM), and Stroke Impact Scale-16 (SIS-16). Sensitivity to change was determined with the Wilcoxon signed rank test and by the calculation of standardized response means. Spearman correlations were used to assess concurrent validity of the total STREAM and STREAM subscales with the FIM and SIS-16 on admission and discharge. We determined predictive validity for all instruments by correlating admission scores with actual and predicted length of stay and by testing associations between admission scores and discharge destination (home vs subacute facility). Not applicable. For all instruments, there was statistically significant improvement from admission to discharge. The standardized response means for the total STREAM and STREAM subscales were large. Spearman correlations between the total STREAM and STREAM subscales and the FIM and SIS-16 were moderate to excellent, both on admission and discharge. Among change scores, only the SIS-16 correlated with the total STREAM. All 3 instruments were significantly associated with discharge destination; however, the associations were strongest for the total STREAM and STREAM subscales. All instruments showed moderate-to-excellent correlations with predicted and actual length of stay. The STREAM is sensitive to change and demonstrates good concurrent and predictive validity as compared with the FIM and SIS-16 in the acute inpatient rehabilitation population. Copyright © 2011 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  14. Psychometric properties and cross-cultural adaptation of the Brazilian Quebec back pain disability scale questionnaire.

    PubMed

    Rodrigues, Marcelo F; Michel-Crosato, Edgard; Cardoso, Jefferson R; Traebert, Jefferson

    2009-06-01

    Cross-cultural translation and psychometric testing. To translate and cross-culturally adapt the Quebec Back Pain Disability Scale (QDS) to Brazilian Portuguese and to examine its validity and reliability. Current literature shows the need to adopt reliable and internationally standardized methods for the analysis of low back pain. To our knowledge, this specific questionnaire has not been translated and validated for Portuguese-speaking patients. The translation and cross-cultural adaptation of the QDS were developed in agreement with internationally recommended methodology, and the resulting product was evaluated in this study with 54 consecutive patients. Internal consistency was obtained through Cronbach's alpha; reliability was estimated through the intraclass correlation coefficient and the Bland and Altman agreement (d = mean difference). Validity was determined by correlating the scores of the Brazil-QDS with the Brazilian version of the Roland-Morris Questionnaire and Visual Analogue Pain Scale by means of the Spearman rank correlation coefficient. The internal consistency obtained was excellent (Cronbach's alpha = 0.97). Intraobserver and interobserver reliability were considered strong (ICC = 0.93-d = 0.68 and 0.96-d = 0.57, respectively). The correlation with Brazilian Roland-Morris Questionnaire and with the Visual Analogue Scale was high (r = 0.857; r = 0.758, respectively). The data showed that the process of translation and cross-cultural adaptation were successful and that the adapted instrument demonstrated excellent psychometric properties.

  15. Development of a Microsoft Excel tool for applying a factor retention criterion of a dimension coefficient to a survey on patient safety culture.

    PubMed

    Chien, Tsair-Wei; Shao, Yang; Jen, Dong-Hui

    2017-10-27

    Many quality-of-life studies have been conducted in healthcare settings, but few have used Microsoft Excel to incorporate Cronbach's α with dimension coefficient (DC) for describing a scale's characteristics. To present a computer module that can report a scale's validity, we manipulated datasets to verify a DC that can be used as a factor retention criterion for demonstrating its usefulness in a patient safety culture survey (PSC). Microsoft Excel Visual Basic for Applications was used to design a computer module for simulating 2000 datasets fitting the Rasch rating scale model. The datasets consisted of (i) five dual correlation coefficients (correl. = 0.3, 0.5, 0.7, 0.9, and 1.0) on two latent traits (i.e., true scores) following a normal distribution and responses to their respective 1/3 and 2/3 items in length; (ii) 20 scenarios of item lengths from 5 to 100; and (iii) 20 sample sizes from 50 to 1000. Each item containing 5-point polytomous responses was uniformly distributed in difficulty across a ± 2 logit range. Three methods (i.e., dimension interrelation ≥0.7, Horn's parallel analysis (PA) 95% confidence interval, and individual random eigenvalues) were used for determining one factor to retain. DC refers to the binary classification (1 as one factor and 0 as many factors) used for examining accuracy with the indicators sensitivity, specificity, and area under receiver operating characteristic curve (AUC). The scale's reliability and DC were simultaneously calculated for each simulative dataset. PSC real data were demonstrated with DC to interpret reports of the unit-based construct validity using the author-made MS Excel module. The DC method presented accurate sensitivity (=0.96), specificity (=0.92) with a DC criterion (≥0.70), and AUC (=0.98) that were higher than those of the two PA methods. PA combined with DC yielded good sensitivity (=0.96), specificity (=1.0) with a DC criterion (≥0.70), and AUC (=0.99). Advances in computer technology may enable healthcare users familiar with MS Excel to apply DC as a factor retention criterion for determining a scale's unidimensionality and evaluating a scale's quality.

  16. Validity and reliability of the Brazilian version of Yale-Brown obsessive compulsive scale-shopping version (YBOCS-SV).

    PubMed

    Leite, Priscilla Lourenço; Filomensky, Tatiana Zambrano; Black, Donald W; Silva, Adriana Cardoso

    2014-08-01

    The Yale-Brown Obsessive Compulsive Scale-Shopping Version (YBOCS-SV) is considered the gold standard in the assessment of shopping severity. It is designed to assess cognitions and behaviors relating to compulsive buying behavior. The present study aims to assess the validity of the Brazilian version of this scale. For the study, composed the sample 610 participants: 588 subjects of a general population and 22 compulsive buyers. Factorial analysis was performed to assess the relations and the correlation between the YBOCS-SV, the Compulsive Buying Scale (CBS), and Richmond Compulsive Buying Scale (RCBS), was assessed using Pearson coefficient, for study of convergent and divergent validity. Cronbach's alpha coefficients were used to assess internal consistency. The results show good to excellent psychometric parameters for the YBOCS-SV in its Brazilian version. With regard to correlations, the YBOCS-SV is inversely and proportionally correlated with CBS and the RCBS, indicating that the YBOCS-SV is an excellent instrument for screening compulsive buying. The YBOCS-SV presented high alpha coefficient of Cronbach's alpha (0.92), demonstrating good reliability. The Brazilian version of the YBOCS-SV is indicated to diagnose compulsive buying disorder, and likely use for the purposes intended in the Brazilian population. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Warm Dense Matter Demonstrating Non-Drude Conductivity from Observations of Nonlinear Plasmon Damping

    NASA Astrophysics Data System (ADS)

    Witte, B. B. L.; Fletcher, L. B.; Galtier, E.; Gamboa, E.; Lee, H. J.; Zastrau, U.; Redmer, R.; Glenzer, S. H.; Sperling, P.

    2017-06-01

    We present simulations using finite-temperature density-functional-theory molecular dynamics to calculate the dynamic electrical conductivity in warm dense aluminum. The comparison between exchange-correlation functionals in the Perdew-Burke-Enzerhof and Heyd-Scuseria-Enzerhof (HSE) approximation indicates evident differences in the density of states and the dc conductivity. The HSE calculations show excellent agreement with experimental Linac Coherent Light Source x-ray plasmon scattering spectra revealing plasmon damping below the widely used random phase approximation. These findings demonstrate non-Drude-like behavior of the dynamic conductivity that needs to be taken into account to determine the optical properties of warm dense matter.

  18. Performance of the PROMIS in Patients After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Scott, Elizabeth J.; Westermann, Robert; Glass, Nathalie A.; Hettrich, Carolyn; Wolf, Brian R.; Bollier, Matthew J.

    2018-01-01

    Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) is designed to advance patient-reported outcome (PRO) instruments by utilizing question banks for major health domains. Purpose: To compare the responsiveness and construct validity of the PROMIS physical function computer adaptive test (PF CAT) with current PRO instruments for patients before and up to 2 years after anterior cruciate ligament (ACL) reconstruction. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Initially, 157 patients completed the PROMIS PF CAT, Short Form–36 Health Survey (SF-36 physical function [PF] and general health [GH]), Marx Activity Rating Scale (MARS), Knee injury and Osteoarthritis Outcome Score (KOOS activities of daily living [ADL], sport, and quality of life [QOL]), and EuroQol–5 dimensions questionnaire (EQ-5D) at 6 weeks, 6 months, and 2 years after ACL reconstruction. Correlations between instruments, ceiling and floor effects, effect sizes (Cohen d), and standardized response means to describe responsiveness were evaluated. Subgroup analyses compared participants with and without additional arthroscopic procedures using linear mixed models. Results: At baseline, 6 weeks, and 6 months, the PROMIS PF CAT showed excellent or excellent-good correlations with the SF-36 PF (r = 0.75-0.80, P < .01), KOOS-ADL (r = 0.63-0.70, P < .01), and KOOS-sport (r = 0.32-0.69, P < .01); excellent-good correlation with the EQ-5D (r = 0.60-0.71, P < .01); and good correlation with the KOOS-QOL (r = 0.52-0.58, P < .01). As expected, there were poor correlations with the MARS (r = 0.00-0.24, P < .01) and SF-36 GH (r = 0.16-0.34, P < .01 ). At 2 years, the PROMIS PF CAT showed good to excellent correlations with all PRO instruments (r = 0.42-0.72, P < .01), including the MARS (r = 0.42, P < .01), indicating frequent return to preinjury function. The PROMIS PF CAT had the fewest ceiling or floor effects of all instruments tested, and patients answered, on average, 4 questions. There was no significant difference in baseline physical function scores between subgroups; at follow-up, all groups showed improvements in scores that were not statistically different. Conclusion: The PROMIS PF CAT is a valid tool to assess outcomes after ACL reconstruction up to 2 years after surgery, demonstrating the highest responsiveness to change with the fewest ceiling and floor effects and a low time burden among all instruments tested. The PROMIS PF CAT is a beneficial alternative for assessing physical function in adults before and after ACL reconstruction. PMID:29854864

  19. Performance of the PROMIS in Patients After Anterior Cruciate Ligament Reconstruction.

    PubMed

    Scott, Elizabeth J; Westermann, Robert; Glass, Nathalie A; Hettrich, Carolyn; Wolf, Brian R; Bollier, Matthew J

    2018-05-01

    The Patient-Reported Outcomes Measurement Information System (PROMIS) is designed to advance patient-reported outcome (PRO) instruments by utilizing question banks for major health domains. To compare the responsiveness and construct validity of the PROMIS physical function computer adaptive test (PF CAT) with current PRO instruments for patients before and up to 2 years after anterior cruciate ligament (ACL) reconstruction. Cohort study (diagnosis); Level of evidence, 2. Initially, 157 patients completed the PROMIS PF CAT, Short Form-36 Health Survey (SF-36 physical function [PF] and general health [GH]), Marx Activity Rating Scale (MARS), Knee injury and Osteoarthritis Outcome Score (KOOS activities of daily living [ADL], sport, and quality of life [QOL]), and EuroQol-5 dimensions questionnaire (EQ-5D) at 6 weeks, 6 months, and 2 years after ACL reconstruction. Correlations between instruments, ceiling and floor effects, effect sizes (Cohen d ), and standardized response means to describe responsiveness were evaluated. Subgroup analyses compared participants with and without additional arthroscopic procedures using linear mixed models. At baseline, 6 weeks, and 6 months, the PROMIS PF CAT showed excellent or excellent-good correlations with the SF-36 PF ( r = 0.75-0.80, P < .01), KOOS-ADL ( r = 0.63-0.70, P < .01), and KOOS-sport ( r = 0.32-0.69, P < .01); excellent-good correlation with the EQ-5D ( r = 0.60-0.71, P < .01); and good correlation with the KOOS-QOL ( r = 0.52-0.58, P < .01). As expected, there were poor correlations with the MARS ( r = 0.00-0.24, P < .01) and SF-36 GH ( r = 0.16-0.34, P < .01 ). At 2 years, the PROMIS PF CAT showed good to excellent correlations with all PRO instruments ( r = 0.42-0.72, P < .01), including the MARS ( r = 0.42, P < .01), indicating frequent return to preinjury function. The PROMIS PF CAT had the fewest ceiling or floor effects of all instruments tested, and patients answered, on average, 4 questions. There was no significant difference in baseline physical function scores between subgroups; at follow-up, all groups showed improvements in scores that were not statistically different. The PROMIS PF CAT is a valid tool to assess outcomes after ACL reconstruction up to 2 years after surgery, demonstrating the highest responsiveness to change with the fewest ceiling and floor effects and a low time burden among all instruments tested. The PROMIS PF CAT is a beneficial alternative for assessing physical function in adults before and after ACL reconstruction.

  20. Measuring the character strength of wisdom.

    PubMed

    Webster, Jeffrey Dean

    2007-01-01

    This study examined the psychosocial correlates and psychometric properties of the Self-Assessed Wisdom Scale (SAWS). Seventy-three men and 98 women ranging in age from 17-92 years (Mean age = 42.77) completed an expanded, 40-item version of the SAWS, the Loyola Generativity Scale, and the Experiences in Close Relationships Scale. A new definition of wisdom is provided which is operationalized with the SAWS. Results indicated that the SAWS has excellent reliability (test-retest = .838; Cronbach's Alpha = .904). Exploratory and Confirmatory Factor analyses confirmed the five hypothesized dimensions of wisdom and the total SAWS score correlated in predicted directions with generativity (r(169) = .448; p < .01) and attachment avoidance (r(169) = -.239, p < .01) demonstrating construct validity.

  1. Propargylic activation across a heterobimetallic ir-sn catalyst: nucleophilic substitution and indene formation with propargylic alcohols.

    PubMed

    Chatterjee, Paresh Nath; Roy, Sujit

    2010-07-02

    A nucleophilic substitution of propargylic alcohols with carbon (arene, heteroarene, and allyltrimethylsilane), sulfur (thiol), oxygen (alcohol), and nitrogen (sulfonamide) nucleophiles has been demonstrated using a high-valent [Ir(COD)(SnCl(3))Cl(mu-Cl)](2) catalyst in 1,2-dichloroethane to afford the corresponding propargylic products in moderate to excellent yields. Alkyl or aryl substituted tertiary propargylic alcohols produce substituted indenes with bulky arenes via allenylic intermediate. An electrophilic mechanism is proposed from Hammett correlation.

  2. Validation of a prediction model that allows direct comparison of the Oxford Knee Score and American Knee Society clinical rating system.

    PubMed

    Maempel, J F; Clement, N D; Brenkel, I J; Walmsley, P J

    2015-04-01

    This study demonstrates a significant correlation between the American Knee Society (AKS) Clinical Rating System and the Oxford Knee Score (OKS) and provides a validated prediction tool to estimate score conversion. A total of 1022 patients were prospectively clinically assessed five years after TKR and completed AKS assessments and an OKS questionnaire. Multivariate regression analysis demonstrated significant correlations between OKS and the AKS knee and function scores but a stronger correlation (r = 0.68, p < 0.001) when using the sum of the AKS knee and function scores. Addition of body mass index and age (other statistically significant predictors of OKS) to the algorithm did not significantly increase the predictive value. The simple regression model was used to predict the OKS in a group of 236 patients who were clinically assessed nine to ten years after TKR using the AKS system. The predicted OKS was compared with actual OKS in the second group. Intra-class correlation demonstrated excellent reliability (r = 0.81, 95% confidence intervals 0.75 to 0.85) for the combined knee and function score when used to predict OKS. Our findings will facilitate comparison of outcome data from studies and registries using either the OKS or the AKS scores and may also be of value for those undertaking meta-analyses and systematic reviews. ©2015 The British Editorial Society of Bone & Joint Surgery.

  3. The development and evaluation of a novel repurposing of a peripheral gaming device for the acquisition of forces applied to a hydraulic treatment plinth.

    PubMed

    Cooper, Darren; Bevins, Joe; Corbett, Mark

    2018-01-13

    This technical note details the stages taken to create an instrumented hydraulic treatment plinth for the measurement of applied forces in the vertical axis. The modification used a widely available low-cost peripheral gaming device and required only basic construction and computer skills. The instrumented treatment plinth was validated against a laboratory grade force platform across a range of applied masses from 0.5-15 kg, mock Gr I-IV vertebral mobilisations and a dynamic response test. Intraclass correlation coefficients demonstrated poor reliability (0.46) for low masses of 0.5 kg improving to excellent for larger masses up to15 kg respectively; excellent to good reliability (0.97-0.86) for the mock mobilisations and moderate reliability (0.51) for the dynamic response test. The study demonstrates how a cheap peripheral gaming device can be repurposed so that forces applied to a hydraulic treatment plinth can be collected reliably when applied in a clinically reasoned manner. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Performance evaluation of BC-3200 hematology analyzer in a university hospital.

    PubMed

    Peng, L; Bai, L; Nie, L; Wu, Z; Yan, C

    2008-06-01

    The BC-3200 automated hematology analyzer was evaluated and compared with the Beckman-Coulter AcT (Ac.T diff 2) 3-part differential hematology analyzer. The BC-3200 was evaluated according to guidelines published by the International Committee for Standardization in Hematology (ICSH), Clinical and Laboratory Standards Institute (CLSI), and Department of Food and Drug Administration (FDA). The results demonstrated no background, minimal carryover (<0.5%), and excellent linearity for hemoglobin (Hb) level, white blood cell (WBC), red blood cell (RBC), and platelet (PLT) counts (>0.998). Precision was generally acceptable for all complete blood count (CBC) parameters; coefficients of variation (CVs) were within the manufacturer's claims and CVs of CBC parameters, including WBC, RBC and PLT counts, Hb and mean corpuscular volume, were <6%. Correlation between the BC-3200 and Ac.T diff 2 was excellent (r > 0.98) for all major CBC parameters (WBC, RBC, and PLT counts and Hb). We conclude that the overall performance of the BC-3200 is excellent and compares well with that of the Coulter Ac.T diff 2.

  5. Use of PROMIS for Patients Undergoing Primary Total Shoulder Arthroplasty.

    PubMed

    Dowdle, S Blake; Glass, Natalie; Anthony, Chris A; Hettrich, Carolyn M

    2017-09-01

    The Patient-Reported Outcomes Measurement Information System (PROMIS) consists of question banks for health domains through computer adaptive testing (CAT). For patients with glenohumeral arthritis, (1) there would be high correlation between traditional patient-reported outcome (PRO) measures and the PROMIS upper extremity item bank (PROMIS UE) and PROMIS physical function CAT (PROMIS PF CAT), and (2) PROMIS PF CAT would not demonstrate ceiling effects. Cohort study (diagnosis); Level of evidence, 3. Sixty-one patients with glenohumeral osteoarthritis were included. Each patient completed the American Shoulder and Elbow Surgeons (ASES) assessment form, Marx Shoulder Activity Scale, Short Form-36 physical function scale (SF-36 PF), EuroQol 5 Dimensions (EQ-5D) questionnaire, Western Ontario Osteoarthritis Shoulder (WOOS) index, PROMIS PF CAT, and the PROMIS UE. Correlation was defined as high (>0.7), moderate (0.4-0.6), or weak (0.2-0.3). Significant floor and ceiling effects were present if more than 15% of individuals scored the lowest or highest possible total score on any PRO. The PROMIS PF demonstrated excellent correlation with the SF-36 PF ( r = 0.81, P < .0001) and good correlation with the ASES ( r = 0.62, P < .0001), EQ-5D ( r = 0.64, P < .001), and WOOS index ( r = 0.51, P < .01). The PROMIS PF demonstrated low correlation with the Marx scale ( r = 0.29, P = .02). The PROMIS UE demonstrated good correlation with the ASES ( r = 0.55, P < .0001), SF-36 ( r = 0.53, P < .01), EQ-5D ( r = 0.48, P < .01), and WOOS ( r = 0.34, P <.01), and poor correlation with the Marx scale ( r = 0.06, P = .62). There were no ceiling or floor effects observed. The mean number of items administered by the PROMIS PRO was 4. These data suggest that for a patient population with operative shoulder osteoarthritis, PROMIS UE and PROMIS PF CAT may be valid alternative PROs. Additionally, PROMIS PF CAT offers a decreased question burden with no ceiling effects.

  6. Reliability, validity and responsiveness of the German Manchester-Oxford Foot Questionnaire (MOXFQ) in patients with foot or ankle surgery.

    PubMed

    Arbab, Dariusch; Kuhlmann, Katharina; Ringendahl, Hubert; Bouillon, Bertil; Eysel, Peer; König, Dietmar

    2017-06-13

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopaedic procedures. The intention of this study was to develop and culturally adapt a German version of the Manchester-Oxford Foot Questionnaire (MOXFQ) and to evaluate reliability, validity and responsiveness. According to guidelines forward and backward translation has been performed. The German MOXFQ was investigated in 177 consecutive patients before and 6 months after foot or ankle surgery. All patients completed MOXFQ, Foot and Ankle Outcome Score (FAOS), Short form 36 and numeric scales for pain and disability (NRS). Test-Retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German MOXFQ demonstrated excellent test-retest reliability with ICC values >0.9 Cronbach's alpha (α) values demonstrated strong internal consistency. No floor or ceiling effects were observed. As hypothesized MOXFQ subscales correlated strongly with corresponding FAOS and SF-36 domains. All subscales showed excellent (ES/SRM >0.8) responsiveness between preoperative assessment and postoperative follow-up. The German version of the MOXFQ demonstrated good psychometric properties. It proofed to be a valid and reliable instrument for use in foot and ankle patients. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  7. Validation of image analysis techniques to measure skin aging features from facial photographs.

    PubMed

    Hamer, M A; Jacobs, L C; Lall, J S; Wollstein, A; Hollestein, L M; Rae, A R; Gossage, K W; Hofman, A; Liu, F; Kayser, M; Nijsten, T; Gunn, D A

    2015-11-01

    Accurate measurement of the extent skin has aged is crucial for skin aging research. Image analysis offers a quick and consistent approach for quantifying skin aging features from photographs, but is prone to technical bias and requires proper validation. Facial photographs of 75 male and 75 female North-European participants, randomly selected from the Rotterdam Study, were graded by two physicians using photonumeric scales for wrinkles (full face, forehead, crow's feet, nasolabial fold and upper lip), pigmented spots and telangiectasia. Image analysis measurements of the same features were optimized using photonumeric grades from 50 participants, then compared to photonumeric grading in the 100 remaining participants stratified by sex. The inter-rater reliability of the photonumeric grades was good to excellent (intraclass correlation coefficients 0.65-0.93). Correlations between the digital measures and the photonumeric grading were moderate to excellent for all the wrinkle comparisons (Spearman's rho ρ = 0.52-0.89) bar the upper lip wrinkles in the men (fair, ρ = 0.30). Correlations were moderate to good for pigmented spots and telangiectasia (ρ = 0.60-0.75). These comparisons demonstrate that all the image analysis measures, bar the upper lip measure in the men, are suitable for use in skin aging research and highlight areas of improvement for future refinements of the techniques. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons.

  8. Validity and reliability of the Japanese version of the FIM + FAM in patients with cerebrovascular accident.

    PubMed

    Miki, Emi; Yamane, Shingo; Yamaoka, Mai; Fujii, Hiroe; Ueno, Hiroka; Kawahara, Toshie; Tanaka, Keiko; Tamashiro, Hiroaki; Inoue, Eiji; Okamoto, Takatsugu; Kuriyama, Masaru

    2016-09-01

    The study aim was to investigate the validity and reliability of the Functional Independence Measure and Functional Assessment Measure (FIM + FAM), which is unfamiliar in Japan, by using its Japanese version (FIM + FAM-j) in patients with cerebrovascular accident (CVA). Forty-two CVA patients participated. Criterion validity was examined by correlating the full scale and subscales of FIM + FAM-j with several well-established measurements using Spearman's correlation coefficient. Reliability was evaluated by internal consistency (tested by Cronbach's alpha coefficient) and intra-rater reliability (tested by Kendall's tau correlation coefficient). Good-to-excellent criterion validity was found between the full scale and motor subscales of the FIM + FAM-j and the Barthel Index, National Institutes of Health Stroke Scale, modified Rankin Scale, and lower extremity Brunnstrom Recovery Stage. High internal consistency was observed within the full-scale FIM + FAM-j and the motor and cognitive subscales (Cronbach's alphas were 0.968, 0.954, and 0.948, respectively). Additionally, good intra-rater reliability was observed within the full scale and motor subscales, and excellent reliability for the cognitive subscales (taus were 0.83, 0.80, and 0.98, respectively). This study showed that the FIM + FAM-j demonstrated acceptable levels of validity and reliability when used for CVA as a measure of disability.

  9. Dynamics of diamond nanoparticles in solution and cells.

    PubMed

    Neugart, Felix; Zappe, Andrea; Jelezko, Fedor; Tietz, C; Boudou, Jean Paul; Krueger, Anke; Wrachtrup, Jörg

    2007-12-01

    The fluorescence and motional dynamics of single diamond nanocrystals in buffer solution and in living cells is investigated. Stable hydrosols of nanodiamonds in buffer solutions are investigated by fluorescence correlation spectroscopy. Measurement of the effective hydrodynamic radius yields particles of 48 nm diameter, which is in excellent agreement with atomic force microscopy measurements made on the same particles. Fluorescence correlation spectroscopy measurements indicate that nanocrystals easily form aggregates when the buffer pH is changed. This tendency is reduced when the surface of the diamonds is covered with surfactants. Upon incubation, cells spontaneously take up nanocrystals that uniformly distribute in cells. Most of the particles get immobilized within a few minutes. The binding of streptavidin to biotinylated aggregates of 4 nm diameter nanodiamonds is demonstrated.

  10. Correlation between clinical fetal head station and sonographic angle of progression during the second stage of labor.

    PubMed

    Perlman, Sharon; Kivilevitch, Zvi; Moran, Orit; Katorza, Eldad; Kees, Salim; Achiron, Reuven; Gilboa, Yinon

    2017-08-04

    To investigate the correlation between the angle of progression and the clinical fetal head station (FHS) during the second stage of labor, and to build reference range. A prospective, observational study was conducted. Women carrying singleton term pregnancies were enrolled during the second stage of labor. FHS was assessed manually by a senior obstetrician, while the angle of progression (AOP) was assessed by transperineal ultrasound (TPU). Both examiners were blinded to each others results. The correlation between the sonographic AOP and the clinical FHS was analyzed. Seventy patients comprised the study group. Clinical FHS demonstrated an excellent correlation with the sonographic measurement of AOP (Pearson's Correlation 0.642, p < 0.001). This correlation was best described by a cubic regression according to the formula: 123.800 + 10.290 × FHS -2.889 * FHS +0.910, (r 2  = 0.423, p < .001). After aggregation of the mean AOP per FHS, the relative predicted centiles values and standard deviation were calculated. The mean Z score between measured and predicted values of the AOP for a given FHS was 0.007 (range -0.13 to +0.006). Our results demonstrate a significant correlation between the clinical FHS and the TPU measured AOP. These standardized sonographic values may serve the obstetrician as a reliable, objective auxiliary tool for the evaluation of the FHS during the second stage of labor.

  11. Correlative Super-Resolution Microscopy: New Dimensions and New Opportunities.

    PubMed

    Hauser, Meghan; Wojcik, Michal; Kim, Doory; Mahmoudi, Morteza; Li, Wan; Xu, Ke

    2017-06-14

    Correlative microscopy, the integration of two or more microscopy techniques performed on the same sample, produces results that emphasize the strengths of each technique while offsetting their individual weaknesses. Light microscopy has historically been a central method in correlative microscopy due to its widespread availability, compatibility with hydrated and live biological samples, and excellent molecular specificity through fluorescence labeling. However, conventional light microscopy can only achieve a resolution of ∼300 nm, undercutting its advantages in correlations with higher-resolution methods. The rise of super-resolution microscopy (SRM) over the past decade has drastically improved the resolution of light microscopy to ∼10 nm, thus creating exciting new opportunities and challenges for correlative microscopy. Here we review how these challenges are addressed to effectively correlate SRM with other microscopy techniques, including light microscopy, electron microscopy, cryomicroscopy, atomic force microscopy, and various forms of spectroscopy. Though we emphasize biological studies, we also discuss the application of correlative SRM to materials characterization and single-molecule reactions. Finally, we point out current limitations and discuss possible future improvements and advances. We thus demonstrate how a correlative approach adds new dimensions of information and provides new opportunities in the fast-growing field of SRM.

  12. The Relationship between Teachers' Performance on the Ventures for Excellence and Their Teaching Effectiveness

    ERIC Educational Resources Information Center

    Winters, Michael Joseph

    2017-01-01

    This quantitative correlational study examined the relationship between teacher pre-hiring effectiveness evaluation and their performance evaluation scores at the end of the first year of teaching. Prior to this study, it was not known if and to what degree teachers' scores on the Ventures for Excellence B-22 screening interview correlated to…

  13. Psychometric properties of the Liebowitz Social Anxiety Scale (LSAS) in a longitudinal study of African Americans with anxiety disorders.

    PubMed

    Beard, Courtney; Rodriguez, Benjamin F; Moitra, Ethan; Sibrava, Nicholas J; Bjornsson, Andri; Weisberg, Risa B; Keller, Martin B

    2011-06-01

    The Liebowitz Social Anxiety Scale (LSAS) is a widely used measure of social anxiety. However, no study has examined the psychometric properties of the LSAS in an African American sample. The current study examined the LSAS characteristics in 97 African Americans diagnosed with an anxiety disorder. Overall, the original LSAS subscales showed excellent internal consistency and temporal stability. Similar to previous reports, fear and avoidance subscales were so highly correlated that they yielded redundant information. Confirmatory factor analyses for three previously proposed models failed to demonstrate an excellent fit to our data. However, a four-factor model showed minimally acceptable fit. Overall, the LSAS performed similarly in our African American sample as in previous European American samples. Exploratory factor analyses are warranted to determine whether a better factor structure exists for African Americans. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. DNA-encapsulated silver nanodots as ratiometric luminescent probes for hypochlorite detection

    NASA Astrophysics Data System (ADS)

    Park, Soonyoung; Choi, Sungmoon; Yu, Junhua

    2014-03-01

    DNA-encapsulated silver nanodots are noteworthy candidates for bio-imaging probes, thanks to their excellent photophysical properties. The spectral shift of silver nanodot emitters from red to blue shows excellent correlations with the concentration of reactive oxygen species, which makes it possible to develop new types of probes for reactive oxygen species (ROS), such as hypochlorous acid (HOCl), given the outstanding stability of the blue in oxidizing environments. HOCl plays a role as a microbicide in immune systems but, on the other hand, is regarded as a disease contributor. Moreover, it is a common ingredient in household cleaners. There are still great demands to detect HOCl fluxes and their physiological pathways. We introduce a new ratiometric luminescence imaging method based on silver nanodots to sensitively detect hypochlorite. The factors that influence the accuracy of the detection are investigated. Its availability has also been demonstrated by detecting the active component in cleaners.

  15. Dithering Digital Ripple Correlation Control for Photovoltaic Maximum Power Point Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barth, C; Pilawa-Podgurski, RCN

    This study demonstrates a new method for rapid and precise maximum power point tracking in photovoltaic (PV) applications using dithered PWM control. Constraints imposed by efficiency, cost, and component size limit the available PWM resolution of a power converter, and may in turn limit the MPP tracking efficiency of the PV system. In these scenarios, PWM dithering can be used to improve average PWM resolution. In this study, we present a control technique that uses ripple correlation control (RCC) on the dithering ripple, thereby achieving simultaneous fast tracking speed and high tracking accuracy. Moreover, the proposed method solves some ofmore » the practical challenges that have to date limited the effectiveness of RCC in solar PV applications. We present a theoretical derivation of the principles behind dithering digital ripple correlation control, as well as experimental results that show excellent tracking speed and accuracy with basic hardware requirements.« less

  16. CORRELATION PURSUIT: FORWARD STEPWISE VARIABLE SELECTION FOR INDEX MODELS

    PubMed Central

    Zhong, Wenxuan; Zhang, Tingting; Zhu, Yu; Liu, Jun S.

    2012-01-01

    In this article, a stepwise procedure, correlation pursuit (COP), is developed for variable selection under the sufficient dimension reduction framework, in which the response variable Y is influenced by the predictors X1, X2, …, Xp through an unknown function of a few linear combinations of them. Unlike linear stepwise regression, COP does not impose a special form of relationship (such as linear) between the response variable and the predictor variables. The COP procedure selects variables that attain the maximum correlation between the transformed response and the linear combination of the variables. Various asymptotic properties of the COP procedure are established, and in particular, its variable selection performance under diverging number of predictors and sample size has been investigated. The excellent empirical performance of the COP procedure in comparison with existing methods are demonstrated by both extensive simulation studies and a real example in functional genomics. PMID:23243388

  17. Non-iterative characterization of few-cycle laser pulses using flat-top gates.

    PubMed

    Selm, Romedi; Krauss, Günther; Leitenstorfer, Alfred; Zumbusch, Andreas

    2012-03-12

    We demonstrate a method for broadband laser pulse characterization based on a spectrally resolved cross-correlation with a narrowband flat-top gate pulse. Excellent phase-matching by collinear excitation in a microscope focus is exploited by degenerate four-wave mixing in a microscope slide. Direct group delay extraction of an octave spanning spectrum which is generated in a highly nonlinear fiber allows for spectral phase retrieval. The validity of the technique is supported by the comparison with an independent second-harmonic fringe-resolved autocorrelation measurement for an 11 fs laser pulse.

  18. Simplified Chinese version of the Forgotten Joint Score (FJS) for patients who underwent joint arthroplasty: cross-cultural adaptation and validation.

    PubMed

    Cao, Shiqi; Liu, Ning; Han, Wuxiang; Zi, Yunpeng; Peng, Fan; Li, Lexiang; Fu, Qiwei; Chen, Yi; Zheng, Weijie; Qian, Qirong

    2017-01-14

    The Forgotten Joint Score (FJS) is a newly developed health-related quality of life (HRQoL) questionnaire designed to evaluate the awareness after total knee arthroplasty (TKA). This study cross-culturally adapted and psychometrically validated a simplified Chinese version of the FJS (SC-FJS). Cross-cultural adaptation was performed according to the internationally recognized guidelines. One-hundred and fifty participants who underwent primary TKA were recruited in this study. Cronbach's α and intra-class correlations were used to determine reliability. Construct validity was analyzed by evaluating the correlations between SC-FJS and the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the short form (36) health survey (SF-36). Each of the 12 items was properly responded and correlated with the total items. SC-FJS had excellent reliability [Cronbach's α = 0.907, intra-class correlation coefficient (ICC) = 0.970, 95% CI 0.959-0.978). Elimination of any one item in all did not result in a value of Cronbach's α of <0.80. SC-FJS had a high correlation with symptoms (0.67, p < 0.001) and pain (0.60, p < 0.001) domains of KOOS and social functioning (0.66, p < 0.001) domain of SF-36, and it also moderately correlated with function in daily living (0.53, p < 0.001) and function in sport and recreation (0.40, p < 0.001) domains of KOOS, and physical subscale of SF-36 (0.49-0.53, p < 0.001) but had a low (r = 0.20) or not significant (p > 0.05) correlation with mental subscale of SF-36. SC-FJS demonstrated excellent acceptability, internal consistency, reliability, and construct validity, which can be recommended for patients who underwent joint arthroplasty in Mainland China.

  19. Fast Face-Recognition Optical Parallel Correlator Using High Accuracy Correlation Filter

    NASA Astrophysics Data System (ADS)

    Watanabe, Eriko; Kodate, Kashiko

    2005-11-01

    We designed and fabricated a fully automatic fast face recognition optical parallel correlator [E. Watanabe and K. Kodate: Appl. Opt. 44 (2005) 5666] based on the VanderLugt principle. The implementation of an as-yet unattained ultra high-speed system was aided by reconfiguring the system to make it suitable for easier parallel processing, as well as by composing a higher accuracy correlation filter and high-speed ferroelectric liquid crystal-spatial light modulator (FLC-SLM). In running trial experiments using this system (dubbed FARCO), we succeeded in acquiring remarkably low error rates of 1.3% for false match rate (FMR) and 2.6% for false non-match rate (FNMR). Given the results of our experiments, the aim of this paper is to examine methods of designing correlation filters and arranging database image arrays for even faster parallel correlation, underlining the issues of calculation technique, quantization bit rate, pixel size and shift from optical axis. The correlation filter has proved its excellent performance and higher precision than classical correlation and joint transform correlator (JTC). Moreover, arrangement of multi-object reference images leads to 10-channel correlation signals, as sharply marked as those of a single channel. This experiment result demonstrates great potential for achieving the process speed of 10000 face/s.

  20. The effect of nitrogen on the cycling performance in thin-film Si{sub 1-x}N{sub x} anode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, Donggi; Kim, Chunjoong; Lee, Joon-Gon

    2008-09-15

    The effects of nitrogen on the electrochemical properties of silicon-nitrogen (Si{sub 1-x}N{sub x}) thin films were examined in terms of their initial capacities and cycling properties. In particular, Si{sub 0.76}N{sub 0.24} thin films showed negligible initial capacity but an abrupt capacity increase to {approx}2300 mA h/g after {approx}650 cycles. The capacity of pure Si thin films was deteriorated to {approx}20% of the initial level after 200 cycles between 0.02 and 1.2 V at 0.5 C (1 C=4200 mA/g), whereas the Si{sub 0.76}N{sub 0.24} thin films exhibited excellent cycle-life performance after {approx}650 cycles. In addition, the Si{sub 0.76}N{sub 0.24} thin filmsmore » at 50 deg. C showed an abrupt capacity increase at an earlier stage of only {approx}30 cycles. The abnormal electrochemical behaviors in the Si{sub 0.76}N{sub 0.24} thin films were demonstrated to be correlated with the formation of Li{sub 3}N and Si{sub 3}N{sub 4}. - Graphical abstract: The Si{sub 0.76}N{sub 0.24} thin films showed negligible initial capacity, but an abrupt capacity increase to {approx}2300 mA h/g after {approx}650 cycles, followed by excellent cycle-life performance. This abnormal electrochemical behavior was demonstrated to be correlated with the formation of Li{sub 3}N and Si{sub 3}N{sub 4}.« less

  1. Direct comparison of rest and adenosine stress myocardial perfusion CT with rest and stress SPECT

    PubMed Central

    Okada, David R.; Ghoshhajra, Brian B.; Blankstein, Ron; Rocha-Filho, Jose A.; Shturman, Leonid D.; Rogers, Ian S.; Bezerra, Hiram G.; Sarwar, Ammar; Gewirtz, Henry; Hoffmann, Udo; Mamuya, Wilfred S.; Brady, Thomas J.; Cury, Ricardo C.

    2010-01-01

    Introduction We have recently described a technique for assessing myocardial perfusion using adenosine-mediated stress imaging (CTP) with dual source computed tomography. SPECT myocardial perfusion imaging (SPECT-MPI) is a widely utilized and extensively validated method for assessing myocardial perfusion. The aim of this study was to determine the level of agreement between CTP and SPECT-MPI at rest and under stress on a per-segment, per-vessel, and per-patient basis. Methods Forty-seven consecutive patients underwent CTP and SPECT-MPI. Perfusion images were interpreted using the 17 segment AHA model and were scored on a 0 (normal) to 3 (abnormal) scale. Summed rest and stress scores were calculated for each vascular territory and patient by adding corresponding segmental scores. Results On a per-segment basis (n = 799), CTP and SPECT-MPI demonstrated excellent correlation: Goodman-Kruskall γ = .59 (P < .0001) for stress and .75 (P < .0001) for rest. On a per-vessel basis (n = 141), CTP and SPECT-MPI summed scores demonstrated good correlation: Pearson r = .56 (P < .0001) for stress and .66 (P < .0001) for rest. On a per-patient basis (n = 47), CTP and SPECT-MPI demonstrated good correlation: Pearson r = .60 (P < .0001) for stress and .76 (P < .0001) for rest. Conclusions CTP compares favorably with SPECT-MPI for detection, extent, and severity of myocardial perfusion defects at rest and stress. PMID:19936863

  2. Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb.

    PubMed

    Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A

    2017-11-01

    Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.

  3. Consistency of clinical biomechanical measures between three different institutions: implications for multi-center biomechanical and epidemiological research.

    PubMed

    Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E

    2014-05-01

    Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.

  4. Excellent Intra and Inter-Observer Reproducibility of Wrist Circumference Measurements in Obese Children and Adolescents

    PubMed Central

    Campagna, Giuseppe; Zampetti, Simona; Gallozzi, Alessia; Giansanti, Sara; Chiesa, Claudio; Pacifico, Lucia; Buzzetti, Raffaella

    2016-01-01

    In a previous study, we found that wrist circumference, in particular its bone component, was associated with insulin resistance in a population of overweight/obese children. The aim of the present study was to evaluate the intra- and inter-operator variability in wrist circumference measurement in a population of obese children and adolescents. One hundred and two (54 male and 48 female) obese children and adolescents were consecutively enrolled. In all subjects wrist circumferences were measured by two different operators two times to assess intra- and inter-operator variability. Statistical analysis was performed using SAS v.9.4 and JMP v.12. Measurements of wrist circumference showed excellent inter-operator reliability with Intra class Correlation Coefficients (ICC) of 0.96 and ICC of 0.97 for the first and the second measurement, respectively. The intra-operator reliability was, also, very strong with a Concordance Correlation Coefficient (CCC) of 0.98 for both operators. The high reproducibility demonstrated in our results suggests that wrist circumference measurement, being safe, non-invasive and repeatable can be easily used in out-patient settings to identify youths with increased risk of insulin-resistance. This can avoid testing the entire population of overweight/obese children for insulin resistance parameters. PMID:27294398

  5. Angular correlations of photons from solution diffraction at a free-electron laser encode molecular structure

    DOE PAGES

    Mendez, Derek; Watkins, Herschel; Qiao, Shenglan; ...

    2016-09-26

    During X-ray exposure of a molecular solution, photons scattered from the same molecule are correlated. If molecular motion is insignificant during exposure, then differences in momentum transfer between correlated photons are direct measurements of the molecular structure. In conventional small- and wide-angle solution scattering, photon correlations are ignored. This report presents advances in a new biomolecular structural analysis technique, correlated X-ray scattering (CXS), which uses angular intensity correlations to recover hidden structural details from molecules in solution. Due to its intense rapid pulses, an X-ray free electron laser (XFEL) is an excellent tool for CXS experiments. A protocol is outlinedmore » for analysis of a CXS data set comprising a total of half a million X-ray exposures of solutions of small gold nanoparticles recorded at the Spring-8 Ångström Compact XFEL facility (SACLA). From the scattered intensities and their correlations, two populations of nanoparticle domains within the solution are distinguished: small twinned, and large probably non-twinned domains. Finally, it is shown analytically how, in a solution measurement, twinning information is only accessible via intensity correlations, demonstrating how CXS reveals atomic-level information from a disordered solution of like molecules.« less

  6. Low-cost spectrometers and learning applications for exposing kids to optics

    NASA Astrophysics Data System (ADS)

    Khodadad, Iman; Abedzadeh, Navid; Lakshminarayan, Vasudevan; Saini, Simarjeet S.

    2015-10-01

    We designed and built a low-cost imaging spectrometer using an in-house grating and a webcam and demonstrated its applications for active learning in science with experiments ranging from understanding light spectra from various sources to detecting adulteration in edible oils. The experiments were designed and run in an elementary school in Waterloo, Ontario with young students from grade 4 to grade 8. The performance of the spectrometer is benchmarked to commercial spectrometers and showed excellent correlation for wavelengths between 450 nm to 650 nm. The spectral range can be improved by removing infra-red filters integrated in webcams.

  7. Secondary benzylation with benzyl alcohols catalyzed by a high-valent heterobimetallic Ir-Sn complex.

    PubMed

    Podder, Susmita; Choudhury, Joyanta; Roy, Sujit

    2007-04-13

    A highly efficient secondary benzylation procedure has been demonstrated using a high-valent heterobimetallic complex [Ir2(COD)2(SnCl3)2(Cl)2(mu-Cl)2] 1 as the catalyst in 1,2-dichloroethane to afford the corresponding benzylated products in moderate to excellent yields. The reaction was performed not only with carbon nucleophiles (arenes and heteroarenes) but also with oxygen (alcohol), nitrogen (amide and sulfonamide), and sulfur (thiol) nucleophiles. Mechanistic investigation showed the intermediacy of the ether in this reaction. An electrophilic mechanism is proposed from Hammett correlation.

  8. Use of PROMIS for Patients Undergoing Primary Total Shoulder Arthroplasty

    PubMed Central

    Dowdle, S. Blake; Glass, Natalie; Anthony, Chris A.; Hettrich, Carolyn M.

    2017-01-01

    Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) consists of question banks for health domains through computer adaptive testing (CAT). Hypothesis: For patients with glenohumeral arthritis, (1) there would be high correlation between traditional patient-reported outcome (PRO) measures and the PROMIS upper extremity item bank (PROMIS UE) and PROMIS physical function CAT (PROMIS PF CAT), and (2) PROMIS PF CAT would not demonstrate ceiling effects. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Sixty-one patients with glenohumeral osteoarthritis were included. Each patient completed the American Shoulder and Elbow Surgeons (ASES) assessment form, Marx Shoulder Activity Scale, Short Form–36 physical function scale (SF-36 PF), EuroQol 5 Dimensions (EQ-5D) questionnaire, Western Ontario Osteoarthritis Shoulder (WOOS) index, PROMIS PF CAT, and the PROMIS UE. Correlation was defined as high (>0.7), moderate (0.4-0.6), or weak (0.2-0.3). Significant floor and ceiling effects were present if more than 15% of individuals scored the lowest or highest possible total score on any PRO. Results: The PROMIS PF demonstrated excellent correlation with the SF-36 PF (r = 0.81, P < .0001) and good correlation with the ASES (r = 0.62, P < .0001), EQ-5D (r = 0.64, P < .001), and WOOS index (r = 0.51, P < .01). The PROMIS PF demonstrated low correlation with the Marx scale (r = 0.29, P = .02). The PROMIS UE demonstrated good correlation with the ASES (r = 0.55, P < .0001), SF-36 (r = 0.53, P < .01), EQ-5D (r = 0.48, P < .01), and WOOS (r = 0.34, P <.01), and poor correlation with the Marx scale (r = 0.06, P = .62). There were no ceiling or floor effects observed. The mean number of items administered by the PROMIS PRO was 4. Conclusion: These data suggest that for a patient population with operative shoulder osteoarthritis, PROMIS UE and PROMIS PF CAT may be valid alternative PROs. Additionally, PROMIS PF CAT offers a decreased question burden with no ceiling effects. PMID:28944248

  9. Multiple description distributed image coding with side information for mobile wireless transmission

    NASA Astrophysics Data System (ADS)

    Wu, Min; Song, Daewon; Chen, Chang Wen

    2005-03-01

    Multiple description coding (MDC) is a source coding technique that involves coding the source information into multiple descriptions, and then transmitting them over different channels in packet network or error-prone wireless environment to achieve graceful degradation if parts of descriptions are lost at the receiver. In this paper, we proposed a multiple description distributed wavelet zero tree image coding system for mobile wireless transmission. We provide two innovations to achieve an excellent error resilient capability. First, when MDC is applied to wavelet subband based image coding, it is possible to introduce correlation between the descriptions in each subband. We consider using such a correlation as well as potentially error corrupted description as side information in the decoding to formulate the MDC decoding as a Wyner Ziv decoding problem. If only part of descriptions is lost, however, their correlation information is still available, the proposed Wyner Ziv decoder can recover the description by using the correlation information and the error corrupted description as side information. Secondly, in each description, single bitstream wavelet zero tree coding is very vulnerable to the channel errors. The first bit error may cause the decoder to discard all subsequent bits whether or not the subsequent bits are correctly received. Therefore, we integrate the multiple description scalar quantization (MDSQ) with the multiple wavelet tree image coding method to reduce error propagation. We first group wavelet coefficients into multiple trees according to parent-child relationship and then code them separately by SPIHT algorithm to form multiple bitstreams. Such decomposition is able to reduce error propagation and therefore improve the error correcting capability of Wyner Ziv decoder. Experimental results show that the proposed scheme not only exhibits an excellent error resilient performance but also demonstrates graceful degradation over the packet loss rate.

  10. Developing the Person-Environment Apathy Rating for persons with dementia.

    PubMed

    Jao, Ying-Ling; Algase, Donna L; Specht, Janet K; Williams, Kristine

    2016-08-01

    To develop the Person-Environment Apathy Rating (PEAR) scale that measures environmental stimulation and apathy in persons with dementia and to evaluate its psychometrics. The PEAR scale consists of the PEAR-Environment subscale and PEAR-Apathy subscales. The items were developed via literature review, field testing, expert review, and pilot testing. The construct validity and reliability were examined through video observation. The parent study enrolled 185 institutionalized residents with dementia. For this study, 96 videos were selected from 24 participants. The PEAR-Environment subscale was validated using the Ambiance Scale and the Crowding Index. The PEAR-Apathy subscale was validated using the Neuropsychiatric Inventory (NPI)-Apathy, Passivity in Dementia Scale (PDS), and NPI-Depression. The PEAR-Environment subscale and PEAR-Apathy subscales each consists of six items rated on a 1-4 scale. For validity, the Crowding Index slightly, yet significantly, correlated with the PEAR-Environment subscale total score and three of the individual scores. Ambiance Scale scores, both engaging and soothing, did not correlate with the PEAR-Environment subscale. The PEAR-Apathy highly correlated with the PDS and NPI-Apathy and moderately correlated with the NPI-Depression, suggesting good convergent validity and moderate discriminant validity. For reliability, both environment and apathy subscales demonstrated excellent internal consistency. Although facial expression and eye contact showed moderate inter-rater reliability, all other items showed good to excellent inter-rater and intra-rater reliability. This study has successfully developed the PEAR scale and established its psychometrics based on the compatible scales available. The PEAR scale is the first scale that concurrently assesses apathy and environmental stimulation, and is recommended for use in persons with dementia.

  11. Correlation of apparent diffusion coefficient ratio on 3.0 T MRI with prostate cancer Gleason score.

    PubMed

    Jyoti, Rajeev; Jain, Tarun Pankaj; Haxhimolla, Hodo; Liddell, Heath; Barrett, Sean Edward

    2018-01-01

    The purpose was to investigate the usefulness of ADC ratio on Diffusion MRI to discriminate between benign and malignant lesions of Prostate. Images of patients who underwent in-gantry MRI guided prostate lesion biopsy were retrospectively analyzed. Prostate Cancers with 20% or more Gleason score (GS) pattern 3 + 3 = 6 in each core or any volume of higher Gleason score pattern were included. ADC ratio was calculated by two reviewers for each lesion. The ADC ratio was calculated for each lesion by dividing the lowest ADC value in a lesion and highest ADC value in normal prostate in peripheral zone (PZ). ADC ratio values were compared with the biopsy result. Data was analysed using independent samples T-test, Spearman correlation, intra-class correlation coefficient (ICC) and Receiver operating characteristic (ROC) curve. 45 lesions in 33 patients were analyzed. 12 lesions were in transitional zone (TZ) and 33 in perpheral zone PZ. All lesions demonstrated an ADC ratio of 0.45 or lower. GS demonstrated a negative correlation with both the ADC value and ADC ratio . However, ADC ratio (p < 0.001) demonstrated a stronger correlation compared to ADC value alone (p = 0.014). There was no significant statistical difference between GS 3 + 4 and GS 4 + 3 mean ADC tumour value (p = 0.167). However when using ADC ratio , there was a significant difference (p = 0.032). ROC curve analysis demonstrated an area under the curve of 0.83 using ADC ratio and 0.76 when using ADC tumour value when discriminating Gleason 6 from Gleason ≥7 tumours. Inter-observer reliability in the calculation of ADC ratios was excellent, with ICC of 0.964. ADC ratio is a reliable and reproducible tool in quantification of diffusion restriction for clinically significant prostate cancer foci.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guiriec, S.; Kouveliotou, C.; Hartmann, D. H.

    The origin of prompt emission from gamma-ray bursts (GRBs) remains to be an open question. Correlated prompt optical and γ -ray emission observed in a handful of GRBs strongly suggests a common emission region, but failure to adequately fit the broadband GRB spectrum prompted the hypothesis of different emission mechanisms for the low- and high-energy radiations. We demonstrate that our multi-component model for GRB γ -ray prompt emission provides an excellent fit to GRB 110205A from optical to γ -ray energies. Our results show that the optical and highest γ -ray emissions have the same spatial and spectral origin, whichmore » is different from the bulk of the X- and softest γ -ray radiation. Finally, our accurate redshift estimate for GRB 110205A demonstrates promise for using GRBs as cosmological standard candles.« less

  13. Equivalence of litmus paper and intragastric pH probes for intragastric pH monitoring in the intensive care unit.

    PubMed

    Levine, R L; Fromm, R E; Mojtahedzadeh, M; Baghaie, A A; Opekun, A R

    1994-06-01

    To compare the accuracy of litmus paper-determined gastric pH to a nasogastric graphite antimony pH probe. A prospective clinical trial of gastric pH determination in patients enrolled in a study of histamine-2-receptor (H2) antagonists. The medical intensive care unit (ICU) of a 450-bed county hospital. Critically ill ICU patients requiring stress ulcer prophylaxis. Using a crossover design, the patients were randomized to initially receive an H2 antagonist by continuous infusion or intravenous bolus, and subsequently were crossed over to the other limb of the study. Gastric pH was determined using pH-sensitive litmus paper at the initiation of each limb of the study and at 1, 2, 4, and 8 hrs after the initiation of H2 receptor antagonist therapy. In addition, gastric pH was continuously determined over the same time period utilizing a graphite antimony pH probe. Gastric pH measurements determined with litmus paper and intragastric pH probes demonstrated an excellent correlation (r2 = .93, p < .001). McNemar's test of correlated proportions could not demonstrate a significant difference between the two monitoring methods (chi-square = 0.5, p > .47), and the kappa statistic (0.95, p < .001) demonstrated excellent concordance. Bias measurement was 0.01 (95% confidence interval = -0.155 to 0.176). Measurement of intragastric pH, using pH-sensitive litmus paper, is both sensitive and specific when utilizing a graphite antimony nasogastric pH probe as a reference standard. Litmus paper-determined gastric pH testing is both easy to perform and inexpensive. Therefore, based on the current data, we believe this technique (i.e., litmus paper determined gastric pH testing) to be the method of choice for determination of intragastric pH in patients at risk for stress gastric ulcers in the medical ICU.

  14. Solar F10.7 radiation - A short term model for Space Station applications

    NASA Technical Reports Server (NTRS)

    Vedder, John D.; Tabor, Jill L.

    1991-01-01

    A new method is described for statistically modeling the F10.7 component of solar radiation for 91-day intervals. The resulting model represents this component of the solar flux as a quasi-exponentially correlated, Weibull distributed random variable, and thereby demonstrates excellent agreement with observed F10.7 data. Values of the F10.7 flux are widely used in models of the earth's upper atmosphere because of its high correlation with density fluctuations due to solar heating effects. Because of the direct relation between atmospheric density and drag, a realistic model of the short term fluctuation of the F10.7 flux is important for the design and operation of Space Station Freedom. The method of modeling this flux described in this report should therefore be useful for a variety of Space Station applications.

  15. Results of the first-in-human clinical trial for MB-102, a novel fluorescent tracer agent for real-time measurement of glomerular filtration rate

    NASA Astrophysics Data System (ADS)

    Dorshow, Richard B.; Debreczeny, Martin P.; Dowling, Thomas C.

    2015-03-01

    The fluorescent tracer agent 2,5-bis[N-(1-carboxy-2-hydroxy)]carbamoyl-3,6-diaminopyrazine, designated MB-102, has been developed with properties and attributes necessary for use as a direct measure of glomerular filtration rate (GFR). Comparison to known standard exogenous GFR agents in animal models has demonstrated an excellent correlation. A clinical trial to demonstrate this same correlation in humans is in progress. This clinical trial is the first in a series of trials necessary to obtain regulatory clearance from the FDA. We report herein the comparison of plasma pharmacokinetics between MB-102 and the known standard exogenous GFR agent Iohexol in healthy subjects with normal renal function. Post simultaneous administration of both agents, blood samples over a period of 12 hours were collected from each subject to assess pharmacokinetic parameters including GFR. Urine samples were collected over this same period to assess percent injected dose recovered in the urine. Results indicate MB-102 is a GFR agent in humans from the comparison to the standard agent.

  16. Measuring a new facet of post traumatic growth: Development of a scale of physical post traumatic growth in men with prostate cancer.

    PubMed

    Walsh, Deirdre M J; Groarke, Ann Marie; Morrison, Todd G; Durkan, Garrett; Rogers, Eamonn; Sullivan, Francis J

    2018-01-01

    This study developed a measure of physical post traumatic growth (physical post traumatic growth inventory; P-PTGI) in men with prostate cancer. A pool of items was created from themes identified in a qualitative study. A quantitative study was then conducted to assess the psychometric properties of the P-PTGI in a sample of 693 prostate cancer survivors. Tests of dimensionality revealed that the 20-item P-PTGI contained two factors: Health Autonomy and Health Awareness. Results demonstrated that scale score reliability for the P-PTGI and its subscales was excellent. In support of the scale's convergent validity, scores on the P-PTGI correlated positively with mindfulness and quality of life, and correlated negatively with depression and anxiety. A statistically significant correlation between the P-PTGI and another robust indicator of post traumatic growth attests to its concurrent validity. While further investigation of the P-PTGI's psychometric properties is required, preliminary findings are promising.

  17. Cross-cultural adaptation, reliability, and validity of the Turkish version of PedsQL 3.0 Arthritis Module: a quality-of-life measure for patients with juvenile idiopathic arthritis in Turkey.

    PubMed

    Tarakci, E; Baydogan, S N; Kasapcopur, O; Dirican, A

    2013-04-01

    The aim of this study was to describe the cultural adaptation, validity, and reliability of a Turkish version of the pediatric quality-of-life inventory (PedsQL) 3.0 Arthritis Module in a population with juvenile idiopathic arthritis (JIA). A total of 169 patients with JIA and their parents were enrolled in the study. The Turkish version of the childhood health assessment questionnaire (CHAQ) was used to evaluate the validity of related domains in the PedsQL 3.0 Arthritis Module. Both the PedsQL 3.0 Arthritis Module and CHAQ were filled out by children over 8 years of age and by the parents of children 2-7 years of age. Internal reliability was poor to excellent (Cronbach's alpha coefficients 0.56-0.84 for self-reporting and 0.63-0.82 for parent reporting), and interobserver reliability varied from good to excellent (intraclass correlation coefficient (ICC) 0.79-0.91 for self-reporting and 0.80-0.88 for parent reporting) for the total scores of the PedsQL 3.0 Arthritis Module. Parent-child concordance for all scores was moderate to excellent (ICC 0.42-0.92). The PedsQL 3.0 Arthritis Module and CHAQ were highly positively correlated, with coefficients from 0.21 to 0.76, indicating concurrent validity. We demonstrated the reliability and validity of quality-of-life measurement using the Turkish version of the PedsQL 3.0 Arthritis Module in our sociocultural context. The PedsQL 3.0 Arthritis Module can be utilized as a tool for the evaluation of quality of life in patients with JIA aged 2-18 years.

  18. The reliability of a maximal isometric hip strength and simultaneous surface EMG screening protocol in elite, junior rugby league athletes.

    PubMed

    Charlton, Paula C; Mentiplay, Benjamin F; Grimaldi, Alison; Pua, Yong-Hao; Clark, Ross A

    2017-02-01

    Firstly to describe the reliability of assessing maximal isometric strength of the hip abductor and adductor musculature using a hand held dynamometry (HHD) protocol with simultaneous wireless surface electromyographic (sEMG) evaluation of the gluteus medius (GM) and adductor longus (AL). Secondly, to describe the correlation between isometric strength recorded with the HHD protocol and a laboratory standard isokinetic device. Reliability and correlational study. A sample of 24 elite, male, junior, rugby league athletes, age 16-20 years participated in repeated HHD and isometric Kin-Com (KC) strength testing with simultaneous sEMG assessment, on average (range) 6 (5-7) days apart by a single assessor. Strength tests included; unilateral hip abduction (ABD) and adduction (ADD) and bilateral ADD assessed with squeeze (SQ) tests in 0 and 45° of hip flexion. HHD demonstrated good to excellent inter-session reliability for all outcome measures (ICC (2,1) =0.76-0.91) and good to excellent association with the laboratory reference KC (ICC (2,1) =0.80-0.88). Whilst intra-session, inter-trial reliability of EMG activation and co-activation outcome measures ranged from moderate to excellent (ICC (2,1) =0.70-0.94), inter-session reliability was poor (all ICC (2,1) <0.50). Isometric strength testing of the hip ABD and ADD musculature using HHD may be measured reliably in elite, junior rugby league athletes. Due to the poor inter-session reliability of sEMG measures, it is not recommended for athlete screening purposes if using the techniques implemented in this study. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  19. Premonitory urges for tics in adult patients with Tourette syndrome.

    PubMed

    Crossley, Eleanor; Seri, Stefano; Stern, Jeremy S; Robertson, Mary M; Cavanna, Andrea E

    2014-01-01

    Patients with Tourette syndrome (TS) often report characteristic sensory experiences, also called premonitory urges (PUs), which precede tic expression and have high diagnostic relevance. This study investigated the usefulness of a scale developed and validated in children and adolescents-the Premonitory Urge for Tics Scale (PUTS, Woods et al., 2005 [13])-for the assessment of PUs in adult patients with TS. Standard statistical methods were applied to test the psychometric properties of the PUTS in 102 adult TS outpatients recruited from two specialist clinics in the United Kingdom. The PUTS showed good acceptability and endorsement rates, with evenly distributed scores and low floor and ceiling effects. Item-total correlations were moderate to strong; PUTS total scores were significantly correlated with quantitative measures of TS severity. The PUTS showed excellent internal consistency reliability (Cronbach's alpha=0.85) and Spearman's correlations demonstrated satisfactory convergent and discriminant validity. Although originally devised to assess urges to tic in young patients with TS, the PUTS demonstrated good psychometric properties in a large sample of adults recruited at specialist TS clinics. This instrument is therefore recommended for use across the life span as a valid and reliable self-report measure of sensory experiences accompanying tic expression. Copyright © 2013 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  20. Increasing the computational efficient of digital cross correlation by a vectorization method

    NASA Astrophysics Data System (ADS)

    Chang, Ching-Yuan; Ma, Chien-Ching

    2017-08-01

    This study presents a vectorization method for use in MATLAB programming aimed at increasing the computational efficiency of digital cross correlation in sound and images, resulting in a speedup of 6.387 and 36.044 times compared with performance values obtained from looped expression. This work bridges the gap between matrix operations and loop iteration, preserving flexibility and efficiency in program testing. This paper uses numerical simulation to verify the speedup of the proposed vectorization method as well as experiments to measure the quantitative transient displacement response subjected to dynamic impact loading. The experiment involved the use of a high speed camera as well as a fiber optic system to measure the transient displacement in a cantilever beam under impact from a steel ball. Experimental measurement data obtained from the two methods are in excellent agreement in both the time and frequency domain, with discrepancies of only 0.68%. Numerical and experiment results demonstrate the efficacy of the proposed vectorization method with regard to computational speed in signal processing and high precision in the correlation algorithm. We also present the source code with which to build MATLAB-executable functions on Windows as well as Linux platforms, and provide a series of examples to demonstrate the application of the proposed vectorization method.

  1. Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion.

    PubMed

    Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A

    2015-05-01

    Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Reliability of Measurement of Glenohumeral Internal Rotation, External Rotation, and Total Arc of Motion in 3 Test Positions

    PubMed Central

    Kevern, Mark A.; Beecher, Michael; Rao, Smita

    2014-01-01

    Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316

  3. Measurement Properties of the Smartphone-Based B-B Score in Current Shoulder Pathologies

    PubMed Central

    Pichonnaz, Claude; Duc, Cyntia; Gleeson, Nigel; Ancey, Céline; Jaccard, Hervé; Lécureux, Estelle; Farron, Alain; Jolles, Brigitte M.; Aminian, Kamiar

    2015-01-01

    This study is aimed at the determination of the measurement properties of the shoulder function B-B Score measured with a smartphone. This score measures the symmetry between sides of a power-related metric for two selected movements, with 100% representing perfect symmetry. Twenty healthy participants, 20 patients with rotator cuff conditions, 23 with fractures, 22 with capsulitis, and 23 with shoulder instabilities were measured twice across a six-month interval using the B-B Score and shoulder function questionnaires. The discriminative power, responsiveness, diagnostic power, concurrent validity, minimal detectable change (MDC), minimal clinically important improvement (MCII), and patient acceptable symptom state (PASS) were evaluated. Significant differences with the control group and significant baseline—six-month differences were found for the rotator cuff condition, fracture, and capsulitis patient groups. The B-B Score was responsive and demonstrated excellent diagnostic power, except for shoulder instability. The correlations with clinical scores were generally moderate to high, but lower for instability. The MDC was 18.1%, the MCII was 25.2%, and the PASS was 77.6. No floor effect was observed. The B-B Score demonstrated excellent measurement properties in populations with rotator cuff conditions, proximal humerus fractures, and capsulitis, and can thus be used as a routine test to evaluate those patients. PMID:26506355

  4. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel II. Distribution functions and moments.

    PubMed

    Langenbucher, Frieder

    2003-01-01

    MS Excel is a useful tool to handle in vitro/in vivo correlation (IVIVC) distribution functions, with emphasis on the Weibull and the biexponential distribution, which are most useful for the presentation of cumulative profiles, e.g. release in vitro or urinary excretion in vivo, and differential profiles such as the plasma response in vivo. The discussion includes moments (AUC and mean) as summarizing statistics, and data-fitting algorithms for parameter estimation.

  5. Van der Waals MoS2/VO2 heterostructure junction with tunable rectifier behavior and efficient photoresponse.

    PubMed

    Oliva, Nicoló; Casu, Emanuele Andrea; Yan, Chen; Krammer, Anna; Rosca, Teodor; Magrez, Arnaud; Stolichnov, Igor; Schueler, Andreas; Martin, Olivier J F; Ionescu, Adrian Mihai

    2017-10-27

    Junctions between n-type semiconductors of different electron affinity show rectification if the junction is abrupt enough. With the advent of 2D materials, we are able to realize thin van der Waals (vdW) heterostructures based on a large diversity of materials. In parallel, strongly correlated functional oxides have emerged, having the ability to show reversible insulator-to-metal (IMT) phase transition by collapsing their electronic bandgap under a certain external stimulus. Here, we report for the first time the electronic and optoelectronic characterization of ultra-thin n-n heterojunctions fabricated using deterministic assembly of multilayer molybdenum disulphide (MoS 2 ) on a phase transition material, vanadium dioxide (VO 2 ). The vdW MoS 2 /VO 2 heterojunction combines the excellent blocking capability of an n-n junction with a high conductivity in on-state, and it can be turned into a Schottky rectifier at high applied voltage or at temperatures higher than 68 °C, exploiting the metal state of VO 2 . We report tunable diode-like current rectification with a good diode ideality factor of 1.75 and excellent conductance swing of 120 mV/dec. Finally, we demonstrate unique tunable photosensitivity and excellent junction photoresponse in the 500/650 nm wavelength range.

  6. Design, fabrication, and testing of a SMA hybrid composite jet engine chevron

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.; Cabell, Randolph H.; Cano, Roberto J.; Fleming, Gary A.

    2006-01-01

    Control of jet noise continues to be an important research topic. Exhaust nozzle chevrons have been shown to reduce jet noise, but parametric effects are not well understood. Additionally, thrust loss due to chevrons at cruise suggests significant benefit from deployable chevrons. The focus of this study is development of an active chevron concept for the primary purpose of parametric studies for jet noise reduction in the laboratory and technology development to leverage for full scale systems. The active chevron concept employed in this work consists of a laminated composite structure with embedded shape memory alloy (SMA) actuators, termed a SMA hybrid composite (SMAHC). The actuators are embedded on one side of the middle surface such that thermal excitation generates a moment and deflects the structure. A brief description of the chevron design is given followed by details of the fabrication approach. Results from bench top tests are presented and correlated with numerical predictions from a model for such structures that was recently implemented in MSC.Nastran and ABAQUS. Excellent performance and agreement with predictions is demonstrated. Results from tests in a representative flow environment are also presented. Excellent performance is again achieved for both open- and closed-loop tests, the latter demonstrating control to a specified immersion into the flow. The actuation authority and immersion performance is shown to be relatively insensitive to nozzle pressure ratio (NPR). Very repeatable immersion control with modest power requirements is demonstrated.

  7. Assessing the validity and reliability of the Pool Activity Level (PAL) Checklist for use with older people with dementia.

    PubMed

    Wenborn, Jennifer; Challis, David; Pool, Jackie; Burgess, Jane; Elliott, Nicola; Orrell, Martin

    2008-03-01

    Activity is key to maintaining physical and mental health and well-being. However, as dementia affects the ability to engage in activity, care-givers can find it difficult to provide appropriate activities. The Pool Activity Level (PAL) Checklist guides the selection of appropriate, personally meaningful activities. The aim of this study was to assess the reliability and validity of the PAL Checklist when used with older people with dementia. A postal questionnaire sent to activity providers assessed content validity. Validity and reliability were measured in a sample of 60 older people with dementia. The questionnaire response rate was 83% (102/122). Most respondents felt no important items were missing. Seven of the nine activities were ranked as 'very important' or 'essential' by at least 77% of the sample, indicating very good content validity. Correlation with measures of cognition, severity of dementia and activity performance demonstrated strong concurrent validity. Inter-item correlation indicated strong construct validity. Cronbach's alpha coefficient measured internal consistency as excellent (0.95). All items achieved acceptable test-retest reliability, and the majority demonstrated acceptable inter-rater reliability. We conclude that the PAL Checklist demonstrates adequate validity and reliability when used with older people with dementia and appears a useful tool for a variety of care settings.

  8. Sensitivity Gains, Linearity, and Spectral Reproducibility in Nonuniformly Sampled Multidimensional MAS NMR Spectra of High Dynamic Range.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suiter, Christopher L.; Paramasivam, Sivakumar; Hou, Guangjin

    Recently, we have demonstrated that considerable inherent sensitivity gains are attained in MAS NMR spectra acquired by nonuniform sampling (NUS) and introduced maximum entropy interpolation (MINT) processing that assures the linearity of transformation between the time and frequency domains. In this report, we examine the utility of the NUS/MINT approach in multidimensional datasets possessing high dynamic range, such as homonuclear 13C–13C correlation spectra. We demonstrate on model compounds and on 1–73-(U-13C,15N)/74–108-(U-15N) E. coli thioredoxin reassembly, that with appropriately constructed 50 % NUS schedules inherent sensitivity gains of 1.7–2.1-fold are readily reached in such datasets. We show that both linearity andmore » line width are retained under these experimental conditions throughout the entire dynamic range of the signals. Furthermore, we demonstrate that the reproducibility of the peak intensities is excellent in the NUS/MINT approach when experiments are repeated multiple times and identical experimental and processing conditions are employed. Finally, we discuss the principles for design and implementation of random exponentially biased NUS sampling schedules for homonuclear 13C–13C MAS correlation experiments that yield high quality artifact-free datasets.« less

  9. Sensitivity gains, linearity, and spectral reproducibility in nonuniformly sampled multidimensional MAS NMR spectra of high dynamic range

    PubMed Central

    Suiter, Christopher L.; Paramasivam, Sivakumar; Hou, Guangjin; Sun, Shangjin; Rice, David; Hoch, Jeffrey C.; Rovnyak, David

    2014-01-01

    Recently, we have demonstrated that considerable inherent sensitivity gains are attained in MAS NMR spectra acquired by nonuniform sampling (NUS) and introduced maximum entropy interpolation (MINT) processing that assures the linearity of transformation between the time and frequency domains. In this report, we examine the utility of the NUS/MINT approach in multidimensional datasets possessing high dynamic range, such as homonuclear 13C–13C correlation spectra. We demonstrate on model compounds and on 1–73-(U-13C, 15N)/74–108-(U-15N) E. coli thioredoxin reassembly, that with appropriately constructed 50 % NUS schedules inherent sensitivity gains of 1.7–2.1-fold are readily reached in such datasets. We show that both linearity and line width are retained under these experimental conditions throughout the entire dynamic range of the signals. Furthermore, we demonstrate that the reproducibility of the peak intensities is excellent in the NUS/MINT approach when experiments are repeated multiple times and identical experimental and processing conditions are employed. Finally, we discuss the principles for design and implementation of random exponentially biased NUS sampling schedules for homonuclear 13C–13C MAS correlation experiments that yield high-quality artifact-free datasets. PMID:24752819

  10. NASA Excellence Award for Quality and Productivity 1989 highlights. The 1989 recipient: Lockheed Engineering and Sciences Company

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The NASA Excellence Award for Productivity and Quality is the result of NASA's desire to encourage superior quality and the continuous improvement philosophy in the aerospace industry. It is awarded to NASA contractors, subcontractors, and suppliers who have demonstrated sustained excellence, customer orientation, and outstanding achievements in a total quality management (TQM) environment. The 'highlights' booklet is intended to transfer successful techniques demonstrated by the performance and quality of major NASA contractors.

  11. A Unified Model for GRB Prompt Emission from Optical to Gamma-Rays; Exploring GRBs as Standard Candles

    NASA Technical Reports Server (NTRS)

    Guiriec, S.; Kouveliotou, C.; Hartmann, D. H.; Granot, J.; Asano, K.; Meszaros, P.; Gill, R.; Gehrels, N.; McEnery, J.

    2016-01-01

    The origin of prompt emission from gamma-ray bursts (GRBs) remains to be an open question. Correlated prompt optical and gamma-ray emission observed in a handful of GRBs strongly suggests a common emission region, but failure to adequately fit the broadband GRB spectrum prompted the hypothesis of different emission mechanisms for the low- and high-energy radiations. We demonstrate that our multi-component model for GRB -ray prompt emission provides an excellent fit to GRB 110205A from optical to gamma-ray energies. Our results show that the optical and highest gamma-ray emissions have the same spatial and spectral origin, which is different from the bulk of the X- and softest gamma-ray radiation. Finally, our accurate redshift estimate for GRB 110205A demonstrates promise for using GRBs as cosmological standard candles.

  12. Defining and Measuring Teaching Excellence in Higher Education in the 21st Century

    ERIC Educational Resources Information Center

    De Courcy, Eileen

    2015-01-01

    Higher Education is in a time of immense change. Colleges and Universities are under greater pressure to demonstrate their value while experiencing increasing levels of economic constraints, changing accountability structures, and pressure to demonstrate excellence in teaching and learning/student outcomes. Technology, elearning and massification…

  13. Translation and Validation of the Korean Version of the International Knee Documentation Committee Subjective Knee Form

    PubMed Central

    Kim, Jin Goo; Lee, Joong Yub; Seo, Seung Suk; Choi, Choong Hyeok; Lee, Myung Chul

    2013-01-01

    Purpose To perform a cross-cultural adaptation and to test the measurement properties of the Korean version of International Knee Documentation Committee (K-IKDC) Subjective Knee Form. Materials and Methods According to the guidelines for cross-cultural adaptation, translation and backward translation of the English version of the IKDC Subjective Knee Form were performed. After translation into the Korean version, 150 patients who had knee-related problems were asked to complete the K-IKDC, Lysholm score, and Short Form-36 (SF-36). Of these patients, 126 were retested 2 weeks later to evaluate test-retest reliability, and 104 were recruited 3 months later to evaluate responsiveness. Construct validity was analyzed by investigating the correlation with Lysholm score and SF-36; content validity was also evaluated. Standardized mean response was calculated for evaluating responsiveness. Results The test-retest reliability proved excellent with a high value for the intraclass correlation coefficient (r=0.94). The internal consistency was strong (Cronbach's α=0.91). Good content validity with absence of floor not ceiling effects and good convergent and divergent validity were observed. Moderate responsiveness was shown (standardized mean response=0.689). Conclusions The K-IKDC demonstrated good measurement properties. We suggest that this instrument is an excellent evaluation instrument that can be used for Korean patients with knee-related injuries. PMID:24032098

  14. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation.

    PubMed

    Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu

    2017-11-01

    To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Evaluation of Psychometric Properties of Voice Activity and Participation Profile (VAPP): A Spanish Version.

    PubMed

    Bermúdez-de-Alvear, Rosa M; Gálvez-Ruiz, Pablo; Martínez-Arquero, A Ginés; Rando-Márquez, Sara; Fernández-Contreras, Elena

    2018-06-11

    This study aimed to analyze the psychometric properties of the Spanish version of the Voice Activity and Participation Profile (SVAPP) questionnaire. A randomized, cross-sectional sampling strategy with controls was used. Two samples with a total of 169 participants were analyzed, specifically 61 men (mean age 37.02) and 108 women (mean age 37.78). Of these participants, 112 were patients and 57 were controls. The instrument was submitted to reliability (internal consistency and corrected item-total correlations) and reproducibility analyses. Validation assessment was based on the construct validity, convergent validity, discriminant validity, and concurrent validity. The global internal consistency was excellent (Cronbach's α = 0.976), corrected item-total correlations were satisfactory and ranged 0.63-0.89, and factor loadings were above 0.50. The different subscales showed good internal consistency (alpha coefficients ranged 0.830-0.956) and test-retest values were consistently associated. The exploratory factor analysis evidenced a strongly defined five factors internal structure, with factors loadings ranging 0.51-0.86. Convergent validity demonstrated that all subscales and scores were very strongly correlated (Pearson r above 0.735) and significantly associated. The discriminant validity analysis showed that SVAPP had good specificity to distinguish dysphonic from healthy voice subjects. Concurrent validity with Voice Handicap Index Spanish version (SVHI) showed very strong correlations between total scores, and between SVHI total score and SVAPP Daily and Social Communication subscales; correlations between both tests subscales were strong; only between SVAPP Work and SVHI Physical sections correlations were moderate. The findings of the present study demonstrated evidence for the SVAPP questionnaire reliability and validity, and provided insightful implications of voice disorders on Spanish patients' quality of life. However, further investigations are required. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  16. Design of pulse waveform for waveform division multiple access UWB wireless communication system.

    PubMed

    Yin, Zhendong; Wang, Zhirui; Liu, Xiaohui; Wu, Zhilu

    2014-01-01

    A new multiple access scheme, Waveform Division Multiple Access (WDMA) based on the orthogonal wavelet function, is presented. After studying the correlation properties of different categories of single wavelet functions, the one with the best correlation property will be chosen as the foundation for combined waveform. In the communication system, each user is assigned to different combined orthogonal waveform. Demonstrated by simulation, combined waveform is more suitable than single wavelet function to be a communication medium in WDMA system. Due to the excellent orthogonality, the bit error rate (BER) of multiuser with combined waveforms is so close to that of single user in a synchronous system. That is to say, the multiple access interference (MAI) is almost eliminated. Furthermore, even in an asynchronous system without multiuser detection after matched filters, the result is still pretty ideal and satisfactory by using the third combination mode that will be mentioned in the study.

  17. Analytical performances of the Diazyme ADA assay on the Cobas® 6000 system.

    PubMed

    Delacour, Hervé; Sauvanet, Christophe; Ceppa, Franck; Burnat, Pascal

    2010-12-01

    To evaluate the analytical performance of the Diazyme ADA assay on the Cobas® 6000 system for pleural fluid samples analysis. Imprecision, linearity, calibration curve stability, interference, and correlation studies were completed. The Diazyme ADA assay demonstrated excellent precision (CV<4%) over the analytical measurement range (0.5-117 U/L). Bilirubin above 50 μmol/L and haemoglobin above 177 μmol/L interfered with the test, inducing a negative and a positive interference respectively. The Diazyme ADA assay correlated well with the Giusti method (r(2)=0.93) but exhibited a negative bias (~ -30%). The Diazyme ADA assay on the Cobas® 6000 system represents a rapid, accurate, precise and reliable method for determination of ADA activity in pleural fluid samples. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Modeling Electronic-Nuclear Interactions for Excitation Energy Transfer Processes in Light-Harvesting Complexes.

    PubMed

    Lee, Mi Kyung; Coker, David F

    2016-08-18

    An accurate approach for computing intermolecular and intrachromophore contributions to spectral densities to describe the electronic-nuclear interactions relevant for modeling excitation energy transfer processes in light harvesting systems is presented. The approach is based on molecular dynamics (MD) calculations of classical correlation functions of long-range contributions to excitation energy fluctuations and a separate harmonic analysis and single-point gradient quantum calculations for electron-intrachromophore vibrational couplings. A simple model is also presented that enables detailed analysis of the shortcomings of standard MD-based excitation energy fluctuation correlation function approaches. The method introduced here avoids these problems, and its reliability is demonstrated in accurate predictions for bacteriochlorophyll molecules in the Fenna-Matthews-Olson pigment-protein complex, where excellent agreement with experimental spectral densities is found. This efficient approach can provide instantaneous spectral densities for treating the influence of fluctuations in environmental dissipation on fast electronic relaxation.

  19. Further validation and definition of the psychometric properties of the Asthma Impact Survey.

    PubMed

    Schatz, Michael; Zeiger, Robert S; Yang, Su-Jau; Chen, Wansu; Kosinski, Mark

    2011-07-01

    The Asthma Impact Survey (AIS-6) is a brief disease-specific quality-of-life instrument with limited published validation data. To obtain additional validation data and psychometric properties of the AIS-6. In November, 2007, patients with persistent asthma were mailed a survey that included the AIS-6, the mini-Asthma Quality of Life Questionnaire (mAQLQ), and the Asthma Control Test (ACT). Follow-up surveys were sent in April, July, and October 2008. Year 2008 exacerbations and short-acting β-agonist (SABA) dispensings were captured from administrative data. A total of 2680 patients had complete baseline survey data. Criterion validity was demonstrated by the strong correlations of the AIS-6 with the mAQLQ (r = -0.84 to -0.86); construct validity by significant relationships (P < .0001) of the AIS-6 with mAQLQ domain scores, ACT score, and history of exacerbations; and predictive validity by significant relationships (P < .0001) between AIS-6 scores at the end of 2007 and year 2008 exacerbations and high SABA dispensings. Responsiveness was demonstrated by significant (P < .0001) correlations (r = -0.39 to -0.58) between changes in AIS-6 scores and changes in mAQLQ and ACT scores over time. A preliminary minimally important difference (MID) in AIS-6 was estimated to be 4 by using the mAQLQ MID as an anchor. Excellent internal consistency (α = 0.94) and test-retest reliability (intraclass correlation coefficient = 0.86-0.91) were also demonstrated. The AIS-6 demonstrated good psychometric properties in a large independent sample and could be used to assess asthma-specific quality of life in clinical practice and clinical research. Copyright © 2011 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  20. Monte Carlo simulation of parameter confidence intervals for non-linear regression analysis of biological data using Microsoft Excel.

    PubMed

    Lambert, Ronald J W; Mytilinaios, Ioannis; Maitland, Luke; Brown, Angus M

    2012-08-01

    This study describes a method to obtain parameter confidence intervals from the fitting of non-linear functions to experimental data, using the SOLVER and Analysis ToolPaK Add-In of the Microsoft Excel spreadsheet. Previously we have shown that Excel can fit complex multiple functions to biological data, obtaining values equivalent to those returned by more specialized statistical or mathematical software. However, a disadvantage of using the Excel method was the inability to return confidence intervals for the computed parameters or the correlations between them. Using a simple Monte-Carlo procedure within the Excel spreadsheet (without recourse to programming), SOLVER can provide parameter estimates (up to 200 at a time) for multiple 'virtual' data sets, from which the required confidence intervals and correlation coefficients can be obtained. The general utility of the method is exemplified by applying it to the analysis of the growth of Listeria monocytogenes, the growth inhibition of Pseudomonas aeruginosa by chlorhexidine and the further analysis of the electrophysiological data from the compound action potential of the rodent optic nerve. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Reliability analysis for digital adolescent idiopathic scoliosis measurements.

    PubMed

    Kuklo, Timothy R; Potter, Benjamin K; O'Brien, Michael F; Schroeder, Teresa M; Lenke, Lawrence G; Polly, David W

    2005-04-01

    Analysis of adolescent idiopathic scoliosis (AIS) requires a thorough clinical and radiographic evaluation to completely assess the three-dimensional deformity. Recently, these radiographic parameters have been analyzed for reliability and reproducibility following manual measurements; however, most of these parameters have not been analyzed with regard to digital measurements. The purpose of this study is to determine the intra- and interobserver reliability of common scoliosis radiographic parameters using a digital software measurement program. Thirty sets of preoperative (posteroanterior [PA], lateral, and side-bending [SB]) and postoperative (PA and lateral) radiographs were analyzed by three independent observers on two separate occasions using a software measurement program (PhDx, Albuquerque, NM). Coronal measures included main thoracic (MT) and thoracolumbar-lumbar (TL/L) Cobb, SB MT Cobb, MT and TL/L apical vertical translation (AVT), C7 to center sacral vertical line (CSVL), T1 tilt, LIV tilt, disk below lowest instrumented vertebra (LIV), coronal balance, and Risser, whereas sagittal measures included T2-T5, T5-T12, T2-T12, T10-L2, T12-S1, and sagittal balance. Analysis of variance for repeated measures or Cohen three-way kappa correlation coefficient analysis was performed as appropriate to calculate the intra- and interobserver reliability for each parameter. The majority of the radiographic parameters assessed demonstrated good or excellent intra- and interobserver reliability. The relationship of the LIV to the CSVL (intraobserver kappaa = 0.48-0.78, fair to excellent; interobserver kappaa = 0.34-0.41, fair to poor), interobserver measurement of AVT (rho = 0.49-0.73, low to good), Risser grade (intraobserver rho = 0.41-0.97, low to excellent; interobserver rho = 0.60-0.70, fair to good), intraobserver measurement of the angulation of the disk inferior to the LIV (rho = 0.53-0.88, fair to good), apical Nash-Moe vertebral rotation (intraobserver rho = 0.50-0.85, fair to good; interobserver rho = 0.53-0.59, fair), and especially regional thoracic kyphosis from T2 to T5 (intraobserver rho = 0.22-0.65, poor to fair; interobserver rho = 0.33-0.47, low) demonstrated lesser reliability. In general, preoperative measures demonstrated greater reliability than postoperative measures, and coronal angular measures were more reliable than sagittal measures. Most common radiographic parameters for AIS assessment demonstrated good or excellent reliability for digital measurement and can be recommended for routine clinical and academic use. Preoperative assessments and coronal measures may be more reliable than postoperative and sagittal measurements. The reliability of digital measurements will be increasingly important as digital radiographic viewing becomes commonplace.

  2. Texas Tech & University of Arizona Win APPA's 2013 Award for Excellence

    ERIC Educational Resources Information Center

    Clendenning, Joanie; Kopach, Christopher M.

    2013-01-01

    APPA's highest institutional honor, the "Award for Excellence in Facilities Management (AFE)," recognizes those educational institutions whose facilities management organizations demonstrate quality in overall operations and effectiveness. The Award for Excellence is based on a set of criteria that include: Leadership; Strategic and…

  3. Correlation between thigh pain and radiological findings with a proximally porous-coated stem.

    PubMed

    Kinov, Plamen; Radl, Roman; Zacherl, Maximilian; Leithner, Andreas; Windhager, Reinhard

    2007-10-01

    Thigh pain has been consistently reported with cementless hip arthroplasty. The correlation between thigh pain and radiological findings and the clinical significance of thigh pain have not been studied in any detail. We carried out a retrospective study to analyse the performance of a proximally porous-coated cementless femoral component. Ninety-eight total hip arthroplasties were followed up clinically and radiologically for an average of 33 months (range: 12 to 64) after operation. The clinical results were good or excellent in 85 cases (87%). Thirteen patients (13%) reported thigh pain at latest follow-up. Subsidence of the stem was recorded in 10 cases, cortical thickening occurred in 14 hips (14%), and 17 hips (17%) presented proximal osteopenia. Proximally, radiolucent lines were observed in 11 cases. Thigh pain correlated with radiolucent lines, femoral thickening, fibrous fixation and stem migration. Bone remodelling was noted to continue even five years after implantation. Our observations demonstrated bone ingrowth in the majority of the cases and a low incidence of thigh pain. The correlation between radiological changes and thigh pain suggests implant micromotion and migration in some hips. Patients with thigh pain, changes in the proximal femur and progressive subsidence need further clinical and radiological follow-up.

  4. Results of the Baikal Experiment on Observations of Macroscopic Nonlocal Correlations in Reverse Time

    NASA Astrophysics Data System (ADS)

    Korotaev, S. M.; Serdyuk, V. O.; Kiktenko, E. O.; Budnev, N. M.; Gorohov, J. V.

    Although the general theory macroscopic quantum entanglement of is still in its infancy, consideration of the matter in the framework of action-at-a distance electrodynamics predicts for the random dissipative processes observability of the advanced nonlocal correlations (time reversal causality). These correlations were really revealed in our previous experiments with some large-scale heliogeophysical processes as the source ones and the lab detectors as the probe ones. Recently a new experiment has been performing on the base of Baikal Deep Water Neutrino Observatory. The thick water layer is an excellent shield against any local impacts on the detectors. The first annual series 2012/2013 has demonstrated that detector signals respond to the heliogeophysical (external) processes and causal connection of the signals directed downwards: from the Earth surface to the Baikal floor. But this nonlocal connection proved to be in reverse time. In addition advanced nonlocal correlation of the detector signal with the regional source-process: the random component of hydrological activity in the upper layer was revealed and the possibility of its forecast on nonlocal correlations was demonstrated. But the strongest macroscopic nonlocal correlations are observed at extremely low frequencies, that is at periods of several months. Therefore the above results should be verified in a longer experiment. We verify them by data of the second annual series 2013/2014 of the Baikal experiment. All the results have been confirmed, although some quantitative parameters of correlations and time reversal causal links turned out different due to nonstationarity of the source-processes. A new result is displaying of the advanced response of nonlocal correlation detector to the earthquake. This opens up the prospect of the earthquake forecast on the new physical principle, although further confirmation in the next events is certainly needed. The continuation of the Baikal experiment with expanded program is burning.

  5. Validity and reliability assessment of the Brazilian version of the game addiction scale (GAS).

    PubMed

    Lemos, Igor Lins; Cardoso, Adriana; Sougey, Everton Botelho

    2016-05-01

    The uncontrolled use of video games can be addictive. The Game Addiction Scale (GAS) is an instrument that was developed to assess this type of addiction. The GAS consists of 21 items that are divided into the following seven factors: salience, tolerance, mood modification, relapse, withdrawal, conflict and problems. This study assessed the convergent validity and reliability of the GAS according to measures of internal consistency and test-retest stability. Three hundred and eighty four students completed the GAS, the Internet Addiction Test (IAT), the Liebowitz Social Anxiety Scale (LSAS), the Beck Depression Inventory (BDI) and the Video Game Addiction Test (VAT). A subgroup of the participants (n=76) completed the GAS again after 30days to determine test-retest stability. The GAS demonstrated excellent internal consistency (Cronbach's alpha=0.92), was highly correlated with the VAT (r=0.883) and was moderately correlated with the BDI (r=0.358), the LSAS (r=0.326) and the IAT (r=0.454). In the Brazilian Portuguese population, the GAS shows good internal consistency. These data indicate that the GAS can be used to assess video game addiction due to its demonstrated psychometric validity. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Automated measurement and classification of pulmonary blood-flow velocity patterns using phase-contrast MRI and correlation analysis.

    PubMed

    van Amerom, Joshua F P; Kellenberger, Christian J; Yoo, Shi-Joon; Macgowan, Christopher K

    2009-01-01

    An automated method was evaluated to detect blood flow in small pulmonary arteries and classify each as artery or vein, based on a temporal correlation analysis of their blood-flow velocity patterns. The method was evaluated using velocity-sensitive phase-contrast magnetic resonance data collected in vitro with a pulsatile flow phantom and in vivo in 11 human volunteers. The accuracy of the method was validated in vitro, which showed relative velocity errors of 12% at low spatial resolution (four voxels per diameter), but was reduced to 5% at increased spatial resolution (16 voxels per diameter). The performance of the method was evaluated in vivo according to its reproducibility and agreement with manual velocity measurements by an experienced radiologist. In all volunteers, the correlation analysis was able to detect and segment peripheral pulmonary vessels and distinguish arterial from venous velocity patterns. The intrasubject variability of repeated measurements was approximately 10% of peak velocity, or 2.8 cm/s root-mean-variance, demonstrating the high reproducibility of the method. Excellent agreement was obtained between the correlation analysis and radiologist measurements of pulmonary velocities, with a correlation of R2=0.98 (P<.001) and a slope of 0.99+/-0.01.

  7. Strategic Decisions & Staff Collaboration Highlight the 2009 Award for Excellence Winners

    ERIC Educational Resources Information Center

    Becker, J. Thomas; Taylor, Matthew M.; Lewis, Dan; Ertzberger, Michelle

    2009-01-01

    APPA's highest institutional honor, the Award for Excellence (AFE) in Facilities Management, recognizes those educational institutions whose facilities management organizations demonstrate quality in overall operations and effectiveness. Fewer than 40 institutions have received this distinct honor. The Award for Excellence is based on a set of…

  8. Structure-activity studies of dicationically substituted bis-benzimidazoles against Giardia lamblia: correlation of antigiardial activity with DNA binding affinity and giardial topoisomerase II inhibition.

    PubMed Central

    Bell, C A; Dykstra, C C; Naiman, N A; Cory, M; Fairley, T A; Tidwell, R R

    1993-01-01

    Nine dicationically substituted bis-benzimidazoles were examined for their in vitro activities against Giardia lamblia WB (ATCC 30957). The potential mechanisms of action of these compounds were evaluated by investigating the relationship among in vitro antigiardial activity and the affinity of the molecules for DNA and their ability to inhibit the activity of giardial topoisomerase II. Each compound demonstrated antigiardial activity, as measured by assessing the incorporation of [methyl-3H]thymidine by giardial trophozoites exposed to the test agents. Three compounds exhibited excellent in vitro antigiardial activities, with 50% inhibitory concentrations which compared very favorably with those of two currently used drugs, quinacrine HCl and metronidazole. Putative mechanisms of action for these compounds were suggested by the strong correlation observed among in vitro antigiardial activity and the affinity of the molecules for natural and synthetic DNA and their ability to inhibit the relaxation activity of giardial topoisomerase II. A strong correlation between the DNA binding affinity of these compounds and their inhibition of giardial topoisomerase II activity was also observed. Images PMID:8109934

  9. Arabic cross cultural adaptation and validation of the National Institutes of Health Stroke Scale.

    PubMed

    Hussein, Haitham M; Abdel Moneim, Amr; Emara, Tamer; Abd-Elhamid, Yousry A; Salem, Haitham H; Abd-Allah, Foad; Farrag, Mohammad A; Tork, M Amir; Shalash, Ali S; Ezz El Dein, Khaled H; Osman, Gamaleldin; Georgy, Shady S; Ghali, Peter G; Lyden, Patrick D; Moustafa, Ramez R

    2015-10-15

    The National Institutes of Health Stroke Scale (NIHSS), the most commonly used tool to quantify neurological deficit in acute stroke, was initially developed in English. We present our experience in developing and validating an Arabic version of the NIHSS (arNIHSS). In 6months, 137 patients were recruited (mean age±standard deviation 62±12years; 48 women). For interrater agreement, weighted kappa value ranged from 0.36 to 0.66 and intraclass correlation coefficient (ICC) for the whole scale was excellent at 0.95 (95% confidence interval [CI] 0.94-0.97). For intrarater agreement, weighted kappa ranged from 0.52 to 1.0 and the ICC was 0.94 (95% CI 0.87-0.98). The construct validity of the arNIHSS is demonstrated by its correlation with the DWI-ASPECT and the 3months mRS score (Spearman correlation -0.46 and 0.58 respectively; P<0.001 for both). We developed and validated a culturally adapted Arabic version of the NIHSS. Further validation in other Arab countries is recommended. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Transcranial Duplex Sonography Predicts Outcome following an Intracerebral Hemorrhage.

    PubMed

    Camps-Renom, P; Méndez, J; Granell, E; Casoni, F; Prats-Sánchez, L; Martínez-Domeño, A; Guisado-Alonso, D; Martí-Fàbregas, J; Delgado-Mederos, R

    2017-08-01

    Several radiologic features such as hematoma volume are related to poor outcome following an intracerebral hemorrhage and can be measured with transcranial duplex sonography. We sought to determine the prognostic value of transcranial duplex sonography in patients with intracerebral hemorrhage. We conducted a prospective study of patients diagnosed with spontaneous intracerebral hemorrhage. Transcranial duplex sonography examinations were performed within 2 hours of baseline CT, and we recorded the following variables: hematoma volume, midline shift, third ventricle and lateral ventricle diameters, and the pulsatility index in both MCAs. We correlated these data with the CT scans and assessed the prognostic value of the transcranial duplex sonography measurements. We assessed early neurologic deterioration during hospitalization and mortality at 1-month follow-up. We included 35 patients with a mean age of 72.2 ± 12.8 years. Median baseline hematoma volume was 9.85 mL (interquartile range, 2.74-68.29 mL). We found good agreement and excellent correlation between transcranial duplex sonography and CT when measuring hematoma volume ( r = 0.791; P < .001) and midline shift ( r = 0.827; P < .001). The logistic regression analysis with transcranial duplex sonography measurements showed that hematoma volume was an independent predictor of early neurologic deterioration (OR, 1.078; 95% CI, 1.023-1.135) and mortality (OR, 1.089; 95% CI, 1.020-1.160). A second regression analysis with CT variables also demonstrated that hematoma volume was associated with early neurologic deterioration and mortality. When we compared the rating operation curves of both models, their predictive power was similar. Transcranial duplex sonography showed an excellent correlation with CT in assessing hematoma volume and midline shift in patients with intracerebral hemorrhage. Hematoma volume measured with transcranial duplex sonography was an independent predictor of poor outcome. © 2017 by American Journal of Neuroradiology.

  11. A validation study on the traditional Chinese version of Spinal Appearance Questionnaire for adolescent idiopathic scoliosis.

    PubMed

    Guo, Jing; Lau, Ajax Hong Yin; Chau, Jack; Ng, Bobby Kin Wah; Lee, Kwong Man; Qiu, Yong; Cheng, Jack Chun Yiu; Lam, Tsz Ping

    2016-10-01

    "Simplified Chinese" version of Spinal Appearance Questionnaire (SC-SAQ) for patients with adolescent idiopathic scoliosis (AIS) was available but did not fit for communities using "Traditional Chinese" as their primary language. We developed a traditional Chinese version of SAQ (TC-SAQ) and evaluated its reliability and validity. TC-SAQ was administered to 112 AIS patients, of which 101 bilingual (English and Chinese) patients completed E-SAQ and the traditional Chinese version of Scoliosis Research Society-22 questionnaire (TC-SRS-22). Internal consistency and test-retest reliability were evaluated. Concurrent validity was evaluated by comparing TC-SAQ score with E-SAQ score, and convergent validity by comparing TC-SAQ score with TC-SRS-22 self-image domain score, and discriminant validity by analyzing the relationship between TC-SAQ score and patients' characteristics. Internal consistency of individual TC-SAQ domain was high (Cronbach's α = 0.785 to 0.940), except for general (Cronbach's α = 0.665) and shoulders (Cronbach's α = 0.421) domain. Test-retest reliability of TC-SAQ was good (ICCs of each domain from 0.798 to 0.865). Concurrent validity demonstrated an excellent correlation between TC-SAQ and E-SAQ scores (r = 0.820 to 0.954, P < 0.0001 for all domains). Correlation between TC-SAQ domains and TC-SRS-22 self-image domain was weak to moderate. TC-SAQ total score and individual domain scores (except waist and chest domains) were positively correlated to major curve magnitude. TC-SAQ had good internal consistency and test-retest reliability. Concurrent validity evaluated against the original English version was excellent. TC-SAQ was both reliable and valid for clinical use for AIS patients using traditional Chinese as their primary language.

  12. Clinical value of patient-specific three-dimensional printing of congenital heart disease: Quantitative and qualitative assessments

    PubMed Central

    Lau, Ivan Wen Wen; Liu, Dongting; Xu, Lei; Fan, Zhanming

    2018-01-01

    Objective Current diagnostic assessment tools remain suboptimal in demonstrating complex morphology of congenital heart disease (CHD). This limitation has posed several challenges in preoperative planning, communication in medical practice, and medical education. This study aims to investigate the dimensional accuracy and the clinical value of 3D printed model of CHD in the above three areas. Methods Using cardiac computed tomography angiography (CCTA) data, a patient-specific 3D model of a 20-month-old boy with double outlet right ventricle was printed in Tango Plus material. Pearson correlation coefficient was used to evaluate correlation of the quantitative measurements taken at analogous anatomical locations between the CCTA images pre- and post-3D printing. Qualitative analysis was conducted by distributing surveys to six health professionals (two radiologists, two cardiologists and two cardiac surgeons) and three medical academics to assess the clinical value of the 3D printed model in these three areas. Results Excellent correlation (r = 0.99) was noted in the measurements between CCTA and 3D printed model, with a mean difference of 0.23 mm. Four out of six health professionals found the model to be useful in facilitating preoperative planning, while all of them thought that the model would be invaluable in enhancing patient-doctor communication. All three medical academics found the model to be helpful in teaching, and thought that the students will be able to learn the pathology quicker with better understanding. Conclusion The complex cardiac anatomy can be accurately replicated in flexible material using 3D printing technology. 3D printed heart models could serve as an excellent tool in facilitating preoperative planning, communication in medical practice, and medical education, although further studies with inclusion of more clinical cases are needed. PMID:29561912

  13. The Cambridge Otology Quality of Life Questionnaire: an otology-specific patient-recorded outcome measure. A paper describing the instrument design and a report of preliminary reliability and validity.

    PubMed

    Martin, T P C; Moualed, D; Paul, A; Ronan, N; Tysome, J R; Donnelly, N P; Cook, R; Axon, P R

    2015-04-01

    The Cambridge Otology Quality of Life Questionnaire (COQOL) is a patient-recorded outcome measurement (PROM) designed to quantify the quality of life of patients attending otology clinics. Item-reduction model. A systematically designed long-form version (74 items) was tested with patient focus groups before being presented to adult otology patients (n. 137). Preliminary item analysis tested reliability, reducing the COQOL to 24 questions. This was then presented in conjunction with the SF-36 (V1) questionnaire to a total of 203 patients. Subsequently, these were re-presented at T + 3 months, and patients recorded whether they felt their condition had improved, deteriorated or remained the same. Non-responders were contacted by post. A correlation between COQOL scores and patient perception of change was examined to analyse content validity. Teaching hospital and university psychology department. Adult patients attending otology clinics with a wide range of otological conditions. Item reliability measured by item–total correlation, internal consistency and test– retest reliability. Validity measured by correlation between COQOL scores and patient-reported symptom change. Reliability: the COQOL showed excellent internal consistency at both initial presentation (a = 0.90) and 3 months later (a = 0.93). Validity: One-way analysis of variance showed a significant difference between groups reporting change and those reporting no change in quality of life (F(2, 80) = 5.866, P < 0.01). The COQOL is the first otology-specific PROM. Initial studies demonstrate excellent reliability and encouraging preliminary criterion validity: further studies will allow a deeper validation of the instrument.

  14. Chaos Through-Wall Imaging Radar

    NASA Astrophysics Data System (ADS)

    Xu, Hang; Wang, Bingjie; Zhang, Jianguo; Liu, Li; Li, Ying; Wang, Yuncai; Wang, Anbang

    2017-12-01

    We experimentally demonstrate a chaos through-wall imaging radar using ultra-wideband chaotic-pulse-position modulation (CPPM) microwave signal. The CPPM signal based on logistic map with 1-ns pulse width and 1-GHz bandwidth is implemented by a field programmable gate array (FPGA) and then up-converted as the radar transmitting signal. Two-dimensional image of human objects behind obstacles is obtained by correlation method and back projection algorithm. Our experiments successfully perform through-wall imaging for single and multiple human objects through 20-cm thick wall. The down-range resolution of the proposed radar is 15 cm. Furthermore, the anti-jamming properties of the proposed radar in CPPM jamming, linear frequency-modulated jamming, and Gaussian noise jamming environments are demonstrated by electromagnetic simulations using the finite-difference time-domain. The simulation results show the CPPM microwave signal possesses excellent jamming immunity to the noise and radio frequency interference, which makes it perform superbly in multiradar environments.

  15. Roadmeter roughness testing in Virginia.

    DOT National Transportation Integrated Search

    1972-01-01

    A passenger car mounted PCA roadmeter has been correlated with the BPR roughometer used for road roughness testing in Virginia for many years. The results showed a good correlation and that the roadmeter is capable of excellent reproducibility. Roadm...

  16. Validity of the American Board of Orthodontics Discrepancy Index and the Peer Assessment Rating Index for comprehensive evaluation of malocclusion severity.

    PubMed

    Liu, S; Oh, H; Chambers, D W; Baumrind, S; Xu, T

    2017-08-01

    To assess the validity of the American Board of Orthodontics Discrepancy Index (ABO-DI) and Peer Assessment Rating (PAR) Index in evaluating malocclusion severity in Chinese orthodontic patients. A stratified random sample of 120 orthodontic patients based on Angle classification was collected from six university orthodontic centres. Sixty-nine orthodontists rated malocclusion severity on a five-point scale by assessing a full set of pre-treatment records for each case and listed reasons for their decision. Their judgement was then compared with ABO-DI and PAR scores determined by three calibrated examiners. Excellent interexaminer reliability of clinician judgement, ABO-DI and PAR index was demonstrated by the Intraclass Correlation Coefficient (rho= 0.995, 0.990 and 0.964, respectively). Both the ABO-DI and US-PAR index showed good correlation with clinician judgement (r=.700 and r=.707, respectively). There was variability among the different Angle classifications: the ABO-DI showed the highest correlation with clinician judgement in Class II patients (r=.780), whereas the US-PAR index showed the highest correlation with clinician judgement in Class III patients (r=.710). Both indices demonstrated the lowest correlations with clinician judgement in Class I patients. With strong interexaminer agreement, the panel consensus was used for validating the ABO-DI and US-PAR index for malocclusion severity. Overall, the ABO-DI and US-PAR index were reliable for measuring malocclusion severity with significantly variable weightings for different Angle classifications. Further modification of the indices for different Angle classification may be indicated. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Coherent Two-Dimensional Terahertz Magnetic Resonance Spectroscopy of Collective Spin Waves.

    PubMed

    Lu, Jian; Li, Xian; Hwang, Harold Y; Ofori-Okai, Benjamin K; Kurihara, Takayuki; Suemoto, Tohru; Nelson, Keith A

    2017-05-19

    We report a demonstration of two-dimensional (2D) terahertz (THz) magnetic resonance spectroscopy using the magnetic fields of two time-delayed THz pulses. We apply the methodology to directly reveal the nonlinear responses of collective spin waves (magnons) in a canted antiferromagnetic crystal. The 2D THz spectra show all of the third-order nonlinear magnon signals including magnon spin echoes, and 2-quantum signals that reveal pairwise correlations between magnons at the Brillouin zone center. We also observe second-order nonlinear magnon signals showing resonance-enhanced second-harmonic and difference-frequency generation. Numerical simulations of the spin dynamics reproduce all of the spectral features in excellent agreement with the experimental 2D THz spectra.

  18. Pulsed Inductive Thruster (PIT): Modeling and Validation Using the MACH2 Code

    NASA Technical Reports Server (NTRS)

    Schneider, Steven (Technical Monitor); Mikellides, Pavlos G.

    2003-01-01

    Numerical modeling of the Pulsed Inductive Thruster exercising the magnetohydrodynamics code, MACH2 aims to provide bilateral validation of the thruster's measured performance and the code's capability of capturing the pertinent physical processes. Computed impulse values for helium and argon propellants demonstrate excellent correlation to the experimental data for a range of energy levels and propellant-mass values. The effects of the vacuum tank wall and massinjection scheme were investigated to show trivial changes in the overall performance. An idealized model for these energy levels and propellants deduces that the energy expended to the internal energy modes and plasma dissipation processes is independent of the propellant type, mass, and energy level.

  19. Molecular Theory for Electrokinetic Transport in pH-Regulated Nanochannels.

    PubMed

    Kong, Xian; Jiang, Jian; Lu, Diannan; Liu, Zheng; Wu, Jianzhong

    2014-09-04

    Ion transport through nanochannels depends on various external driving forces as well as the structural and hydrodynamic inhomogeneity of the confined fluid inside of the pore. Conventional models of electrokinetic transport neglect the discrete nature of ionic species and electrostatic correlations important at the boundary and often lead to inconsistent predictions of the surface potential and the surface charge density. Here, we demonstrate that the electrokinetic phenomena can be successfully described by the classical density functional theory in conjunction with the Navier-Stokes equation for the fluid flow. The new theoretical procedure predicts ion conductivity in various pH-regulated nanochannels under different driving forces, in excellent agreement with experimental data.

  20. Observations of non-linear plasmon damping in dense plasmas

    NASA Astrophysics Data System (ADS)

    Witte, B. B. L.; Sperling, P.; French, M.; Recoules, V.; Glenzer, S. H.; Redmer, R.

    2018-05-01

    We present simulations using finite-temperature density-functional-theory molecular-dynamics to calculate dynamic dielectric properties in warm dense aluminum. The comparison between exchange-correlation functionals in the Perdew, Burke, Ernzerhof approximation, Strongly Constrained and Appropriately Normed Semilocal Density Functional, and Heyd, Scuseria, Ernzerhof (HSE) approximation indicates evident differences in the electron transition energies, dc conductivity, and Lorenz number. The HSE calculations show excellent agreement with x-ray scattering data [Witte et al., Phys. Rev. Lett. 118, 225001 (2017)] as well as dc conductivity and absorption measurements. These findings demonstrate non-Drude behavior of the dynamic conductivity above the Cooper minimum that needs to be taken into account to determine optical properties in the warm dense matter regime.

  1. Validation of the M. D. Anderson Symptom Inventory multiple myeloma module

    PubMed Central

    2013-01-01

    Background The symptom burden associated with multiple myeloma (MM) is often severe. Presently, no instrument comprehensively assesses disease-related and treatment-related symptoms in patients with MM. We sought to validate a module of the M. D. Anderson Symptom Inventory (MDASI) developed specifically for patients with MM (MDASI-MM). Methods The MDASI-MM was developed with clinician input, cognitive debriefing, and literature review, and administered to 132 patients undergoing induction chemotherapy or stem cell transplantation. We demonstrated the MDASI-MM’s reliability (Cronbach α values); criterion validity (item and subscale correlations between the MDASI-MM and the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) and the EORTC MM module (QLQ-MY20)), and construct validity (differences between groups by performance status). Ratings from transplant patients were examined to demonstrate the MDASI-MM’s sensitivity in detecting the acute worsening of symptoms post-transplantation. Results The MDASI-MM demonstrated excellent correlations with subscales of the 2 EORTC instruments, strong ability to distinguish clinically different patient groups, high sensitivity in detecting change in patients’ performance status, and high reliability. Cognitive debriefing confirmed that the MDASI-MM encompasses the breadth of symptoms relevant to patients with MM. Conclusion The MDASI-MM is a valid, reliable, comprehensive-yet-concise tool that is recommended as a uniform symptom assessment instrument for patients with MM. PMID:23384030

  2. Reliability and Validity of the Korean Version of the Symptom Checklist-Post-Traumatic Stress Disorder Scale

    PubMed Central

    2016-01-01

    The Symptom Checklist - Post-Traumatic Stress Disorder Scale (SCL-PTSD), also known as Crime-Related PTSD Scale has been validated in survivors of interpersonal trauma in the general population. However, the psychometric properties have not been investigated in a clinical setting for patients with PTSD from diverse traumatic events. This study investigates the reliability and validity of the Korean version of the SCL-PTSD among 104 psychiatric outpatients with PTSD, caused by interpersonal (n = 50) or non-interpersonal trauma (n = 54). Self-report data of the SCL-PTSD, Beck Depression Inventory (BDI), State-Trait Anxiety Inventory (STAI), and Impact of Events Scale-Revised (IES-R) were gathered. The Korean version of the SCL-PTSD showed excellent internal consistency and moderate-to-good four-week temporal stability in both the interpersonal and non-interpersonal trauma groups. In comparison with other diagnostic groups, the scores of the SCL-PTSD were significantly higher compared to those of adjustment disorder, depression, other anxiety disorders, and schizophrenia, demonstrating its criteria-related validity. Convergent validity was confirmed because the scores of the SCL-PTSD were significantly correlated with BDI, SAI and TAI scores. Concurrent validity was demonstrated by significant correlation with the IES-R score. This study demonstrated the favorable psychometric prosperities of the Korean version of the SCL-PTSD, supporting its use in clinical research and practice. PMID:27134501

  3. External validation of Global Evaluative Assessment of Robotic Skills (GEARS).

    PubMed

    Aghazadeh, Monty A; Jayaratna, Isuru S; Hung, Andrew J; Pan, Michael M; Desai, Mihir M; Gill, Inderbir S; Goh, Alvin C

    2015-11-01

    We demonstrate the construct validity, reliability, and utility of Global Evaluative Assessment of Robotic Skills (GEARS), a clinical assessment tool designed to measure robotic technical skills, in an independent cohort using an in vivo animal training model. Using a cross-sectional observational study design, 47 voluntary participants were categorized as experts (>30 robotic cases completed as primary surgeon) or trainees. The trainee group was further divided into intermediates (≥5 but ≤30 cases) or novices (<5 cases). All participants completed a standardized in vivo robotic task in a porcine model. Task performance was evaluated by two expert robotic surgeons and self-assessed by the participants using the GEARS assessment tool. Kruskal-Wallis test was used to compare the GEARS performance scores to determine construct validity; Spearman's rank correlation measured interobserver reliability; and Cronbach's alpha was used to assess internal consistency. Performance evaluations were completed on nine experts and 38 trainees (14 intermediate, 24 novice). Experts demonstrated superior performance compared to intermediates and novices overall and in all individual domains (p < 0.0001). In comparing intermediates and novices, the overall performance difference trended toward significance (p = 0.0505), while the individual domains of efficiency and autonomy were significantly different between groups (p = 0.0280 and 0.0425, respectively). Interobserver reliability between expert ratings was confirmed with a strong correlation observed (r = 0.857, 95 % CI [0.691, 0.941]). Experts and participant scoring showed less agreement (r = 0.435, 95 % CI [0.121, 0.689] and r = 0.422, 95 % CI [0.081, 0.0672]). Internal consistency was excellent for experts and participants (α = 0.96, 0.98, 0.93). In an independent cohort, GEARS was able to differentiate between different robotic skill levels, demonstrating excellent construct validity. As a standardized assessment tool, GEARS maintained consistency and reliability for an in vivo robotic surgical task and may be applied for skills evaluation in a broad range of robotic procedures.

  4. Desmoplastic melanoma morphology on Thinprep: a report of two cases

    PubMed Central

    Van Ells, Becky L; Madory, James E; Hoda, Rana S

    2007-01-01

    Background Desmoplastic melanoma is a variant of malignant melanoma that can range in appearance from sarcomatoid to scar-like. Cytomorphology of desmoplastic melanoma has been previously described on conventional smears; however, to our knowledge, detailed cytomorphology on ThinPrep has so far not been described. Herein, we describe the cytomorphology of two cases of desmoplastic melanoma on fine needle aspiration processed as ThinPrep slides and compare it to that seen on conventional smears. Pertinent immunocytochemical stains, performed on ThinPrep slides are also discussed. Case presentation The first case is a woman with a history of desmoplastic melanoma of the scalp with previous local recurrences and lymph node metastasis with a new submandibular mass. The second case is a man with a previously resected desmoplastic melanoma with his first local recurrence. Conventional smears, including air-dried Diff-Quik-stained and alcohol-fixed Papanicolaou-stained smears, demonstrated aggregates of pleomorphic spindle cells admixed with fibrous stroma and single spindle cells. In both cases, nuclei were elongated and plump with irregular nuclear contours, deep grooves, and folds. Chromatin was dark and coarse with either inconspicuous or multiple prominent nucleoli. Cytoplasm was located at the nuclear poles and was fine, wispy, and delicate. The background was clean with no evidence of necrosis or melanin pigment. Papanicolaou-stained ThinPrep slides were prepared from needle rinses and demonstrated excellent correlation of nuclear and cytoplasmic detail of single spindle cells to that seen on conventional smears with the exception of only slight decrease in nuclear size; however, nuclear and cytoplasmic detail of spindle cells embedded in stroma was markedly attenuated. Confirmatory immunostain for S-100 protein in both cases was performed on ThinPrep slides demonstrating crisp cytoplasmic staining in the spindle cells. Conclusion The cytomorphology of desmoplastic melanoma shows excellent correlation between cytomorphology of single spindle cells on conventional smears and on ThinPrep slides. The major difference noted on ThinPrep slides was attenuated nuclear and cytoplasmic detail of spindle cells embedded in fibrous stoma. PMID:17880690

  5. Dynamic contrast-enhanced MR imaging of the rectum: Correlations between single-section and whole-tumor histogram analyses.

    PubMed

    Choi, M H; Oh, S N; Park, G E; Yeo, D-M; Jung, S E

    2018-05-10

    To evaluate the interobserver and intermethod correlations of histogram metrics of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) parameters acquired by multiple readers using the single-section and whole-tumor volume methods. Four DCE parameters (K trans , K ep , V e , V p ) were evaluated in 45 patients (31 men and 14 women; mean age, 61±11 years [range, 29-83 years]) with locally advanced rectal cancer using pre-chemoradiotherapy (CRT) MRI. Ten histogram metrics were extracted using two methods of lesion selection performed by three radiologists: the whole-tumor volume method for the whole tumor on axial section-by-section images and the single-section method for the entire area of the tumor on one axial image. The interobserver and intermethod correlations were evaluated using the intraclass correlation coefficients (ICCs). The ICCs showed excellent interobserver and intermethod correlations in most of histogram metrics of the DCE parameters. The ICCs among the three readers were > 0.7 (P<0.001) for all histogram metrics, except for the minimum and maximum. The intermethod correlations for most of the histogram metrics were excellent for each radiologist, regardless of the differences in the radiologists' experience. The interobserver and intermethod correlations for most of the histogram metrics of the DCE parameters are excellent in rectal cancer. Therefore, the single-section method may be a potential alternative to the whole-tumor volume method using pre-CRT MRI, despite the fact that the high agreement between the two methods cannot be extrapolated to post-CRT MRI. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  6. Do Pre-Entry Tests Predict Competencies Required to Excel Academically in Law School?: An Empirical Investigation

    ERIC Educational Resources Information Center

    Wamala, Robert

    2016-01-01

    Purpose: Prospective students of law are required to demonstrate competence in certain disciplines to attain admission to law school. The grounding in the disciplines is expected to demonstrate competencies required to excel academically in law school. The purpose of this study is to investigate the relevance of the law school admission test to…

  7. Student evaluations of teaching: teaching quantitative courses can be hazardous to one’s career

    PubMed Central

    Smibert, Dylan

    2017-01-01

    Anonymous student evaluations of teaching (SETs) are used by colleges and universities to measure teaching effectiveness and to make decisions about faculty hiring, firing, re-appointment, promotion, tenure, and merit pay. Although numerous studies have found that SETs correlate with various teaching effectiveness irrelevant factors (TEIFs) such as subject, class size, and grading standards, it has been argued that such correlations are small and do not undermine the validity of SETs as measures of professors’ teaching effectiveness. However, previous research has generally used inappropriate parametric statistics and effect sizes to examine and to evaluate the significance of TEIFs on personnel decisions. Accordingly, we examined the influence of quantitative vs. non-quantitative courses on SET ratings and SET based personnel decisions using 14,872 publicly posted class evaluations where each evaluation represents a summary of SET ratings provided by individual students responding in each class. In total, 325,538 individual student evaluations from a US mid-size university contributed to theses class evaluations. The results demonstrate that class subject (math vs. English) is strongly associated with SET ratings, has a substantial impact on professors being labeled satisfactory vs. unsatisfactory and excellent vs. non-excellent, and the impact varies substantially depending on the criteria used to classify professors as satisfactory vs. unsatisfactory. Professors teaching quantitative courses are far more likely not to receive tenure, promotion, and/or merit pay when their performance is evaluated against common standards. PMID:28503380

  8. Mechanistic studies of the transdermal iontophoretic delivery of 5-OH-DPAT in vitro.

    PubMed

    Ackaert, Oliver W; Van Smeden, Jeroen; De Graan, Jeroen; Dijkstra, Durk; Danhof, Meindert; Bouwstra, Joke A

    2010-01-01

    A characterization and optimization of the in vitro transdermal iontophoretic transport of 5-hydroxy-2-(N,N,-di-n-propylamino)tetralin (5-OH-DPAT) is presented. The utility of acetaminophen as a marker of electroosmotic flow was studied as well. The following parameters of iontophoretic transport of 5-OH-DPAT were examined: drug donor concentration, electroosmotic contribution, influence of co-ions, current density, and composition of the acceptor phase. The steady-state flux (Flux(ss)) of acetaminophen was linearly correlated with the donor concentration and co-iontophoresis of acetaminophen did not influence the iontophoretic flux of 5-OH-DPAT, indicating that acetaminophen is an excellent marker of electroosmotic flow. Lowering the Na(+) concentration from 78 to 10 mM in the donor phase, resulted in a 2.5-fold enhancement of the Flux(ss). The Flux(ss) showed a nonlinear relation with the drug donor concentration and an excellent linear correlation with the current density. Reducing the pH of the acceptor phase from 7.4 to 6.2 resulted in a dramatic decrease of the Flux(ss) of 5-OH-DPAT, explained by a reduced electroosmotic flow and an increased counter-ion flow. Optimization of the conditions resulted in a maximum Flux(ss) of 5-OH-DPAT of 1.0 micromol x cm(-2) h(-1) demonstrating the potential of the iontophoretic delivery of this dopamine agonist for the symptomatic treatment of Parkinson's disease.

  9. Student evaluations of teaching: teaching quantitative courses can be hazardous to one's career.

    PubMed

    Uttl, Bob; Smibert, Dylan

    2017-01-01

    Anonymous student evaluations of teaching (SETs) are used by colleges and universities to measure teaching effectiveness and to make decisions about faculty hiring, firing, re-appointment, promotion, tenure, and merit pay. Although numerous studies have found that SETs correlate with various teaching effectiveness irrelevant factors (TEIFs) such as subject, class size, and grading standards, it has been argued that such correlations are small and do not undermine the validity of SETs as measures of professors' teaching effectiveness. However, previous research has generally used inappropriate parametric statistics and effect sizes to examine and to evaluate the significance of TEIFs on personnel decisions. Accordingly, we examined the influence of quantitative vs. non-quantitative courses on SET ratings and SET based personnel decisions using 14,872 publicly posted class evaluations where each evaluation represents a summary of SET ratings provided by individual students responding in each class. In total, 325,538 individual student evaluations from a US mid-size university contributed to theses class evaluations. The results demonstrate that class subject (math vs. English) is strongly associated with SET ratings, has a substantial impact on professors being labeled satisfactory vs. unsatisfactory and excellent vs. non-excellent, and the impact varies substantially depending on the criteria used to classify professors as satisfactory vs. unsatisfactory. Professors teaching quantitative courses are far more likely not to receive tenure, promotion, and/or merit pay when their performance is evaluated against common standards.

  10. Graphite Screen-Printed Electrodes Applied for the Accurate and Reagentless Sensing of pH.

    PubMed

    Galdino, Flávia E; Smith, Jamie P; Kwamou, Sophie I; Kampouris, Dimitrios K; Iniesta, Jesus; Smith, Graham C; Bonacin, Juliano A; Banks, Craig E

    2015-12-01

    A reagentless pH sensor based upon disposable and economical graphite screen-printed electrodes (GSPEs) is demonstrated for the first time. The voltammetric pH sensor utilizes GSPEs which are chemically pretreated to form surface immobilized oxygenated species that, when their redox behavior is monitored, give a Nernstian response over a large pH range (1-13). An excellent experimental correlation is observed between the voltammetric potential and pH over the entire pH range of 1-13 providing a simple approach with which to monitor solution pH. Such a linear response over this dynamic pH range is not usually expected but rather deviation from linearity is encountered at alkaline pH values; absence of this has previously been attributed to a change in the pKa value of surface immobilized groups from that of solution phase species. This non-deviation, which is observed here in the case of our facile produced reagentless pH sensor and also reported in the literature for pH sensitive compounds immobilized upon carbon electrodes/surfaces, where a linear response is observed over the entire pH range, is explained alternatively for the first time. The performance of the GSPE pH sensor is also directly compared with a glass pH probe and applied to the measurement of pH in "real" unbuffered samples where an excellent correlation between the two protocols is observed validating the proposed GSPE pH sensor.

  11. Measurement of the perfusion fraction in brain tumors with intravoxel incoherent motion MR imaging: validation with histopathological vascular density in meningiomas.

    PubMed

    Togao, Osamu; Hiwatashi, Akio; Yamashita, Koji; Kikuchi, Kazufumi; Momosaka, Daichi; Yoshimoto, Koji; Kuga, Daisuke; Mizoguchi, Masahiro; Suzuki, Satoshi O; Iwaki, Toru; Van Cauteren, Marc; Iihara, Koji; Honda, Hiroshi

    2018-05-01

    To evaluate the quantification performance of the perfusion fraction (f) measured with intravoxel incoherent motion (IVIM) MR imaging in a comparison with the histological vascular density in meningiomas. 29 consecutive patients with meningioma (59.0 ± 16.8 years old, 8 males and 21 females) who underwent a subsequent surgical resection were examined with both IVIM imaging and a histopathological analysis. IVIM imaging was conducted using a single-shot SE-EPI sequence with 13 b-factors (0, 10, 20, 30, 50, 80, 100, 200, 300, 400, 600, 800, 1000 s mm - 2 ) at 3T. The perfusion fraction (f) was calculated by fitting the IVIM bi-exponential model. The 90-percentile f-value in the tumor region-of-interest (ROI) was defined as the maximum f-value (f-max). Histopathological vascular density (%Vessel) was measured on CD31-immunostainted histopathological specimens. The correlation and agreement between the f-values and %Vessel was assessed. The f-max (15.5 ± 5.5%) showed excellent agreement [intraclass correlation coefficient (ICC) = 0.754] and a significant correlation (r = 0.69, p < 0.0001) with the %Vessel (12.9 ± 9.4%) of the tumors. The Bland-Altman plot analysis showed excellent agreement between the f-max and %Vessel (bias, -2.6%; 95% limits of agreement, from -16.0 to 10.8%). The f-max was not significantly different among the histological subtypes of meningioma. An excellent agreement and a significant correlation were observed between the f-values and %Vessel. The f-value can be used as a noninvasive quantitative imaging measure to directly assess the vascular volume fraction in brain tumors. Advances in knowledge: The f-value measured by IVIM imaging showed a significant correlation and an excellent agreement with the histological vascular density in the meningiomas. The f-value can be used as a noninvasive and quantitative imaging measure to directly assess the volume fraction of capillaries in brain tumors.

  12. Establishing the reliability and concurrent validity of physical performance tests using virtual reality equipment for community-dwelling healthy elders.

    PubMed

    Griswold, David; Rockwell, Kyle; Killa, Carri; Maurer, Michael; Landgraff, Nancy; Learman, Ken

    2015-01-01

    The aim of this study was to determine the reliability and concurrent validity of commonly used physical performance tests using the OmniVR Virtual Rehabilitation System for healthy community-dwelling elders. Participants (N = 40) were recruited by the authors and were screened for eligibility. The initial method of measurement was randomized to either virtual reality (VR) or clinically based measures (CM). Physical performance tests included the five times sit to stand, Timed Up and Go (TUG), Forward Functional Reach (FFR) and 30-s stand test. A random number generator determined the testing order. The test-re-test reliability for the VR and CM was determined. Furthermore, concurrent validity was determined using a Pearson product moment correlation (Pearson r). The VR demonstrated excellent reliability for 5 × STS intraclass correlation coefficient (ICC) = 0.931(3,1), FFR ICC = 0.846(3,1) and the TUG ICC = 0.944(3,1). The concurrent validity data for the VR and CM (ICC 3, k) were moderate for FFR ICC = 0.682, excellent 5 × STS ICC = 0.889 and excellent for the TUG ICC = 0.878. The concurrent validity of the 30-s stand test was good ICC = 0.735(3,1). This study supports the use of VR equipment for measuring physical performance tests in the clinic for healthy community-dwelling elders. Virtual reality equipment is not only used to treat balance impairments but it is also used to measure and determine physical impairments through the use of physical performance tests. Virtual reality equipment is a reliable and valid tool for collecting physical performance data for the 5 × STS, FFR, TUG and 30-s stand test for healthy community-dwelling elders.

  13. Career Technical Education Adjunct Faculty Teacher Readiness: An Investigation of Teacher Excellence and Variables of Preparedness

    ERIC Educational Resources Information Center

    Guerra, Jorge

    2012-01-01

    The purpose of this research was to examine the relationship between teaching readiness and teaching excellence with three variables of preparedness of adjunct professors teaching career technical education courses through student surveys using a correlational design of two statistical techniques; least-squares regression and one-way analysis of…

  14. Underpinning Excellence in Higher Education--An Investigation into the Leadership, Governance and Management Behaviours of High-Performing Academic Departments

    ERIC Educational Resources Information Center

    Kok, Seng Kiat; McDonald, Claire

    2017-01-01

    The changes in government funding alongside external pressures of increased international and national competition have meant that higher education institutions need to excel in a turbulent environment. The leadership, governance and management (LGM) of academic departments are key concerns. This study investigates the correlation between…

  15. Development and initial validation of the Localized Scleroderma Skin Damage Index and Physician Global Assessment of disease Damage: a proof-of-concept study

    PubMed Central

    Vilaiyuk, Soamarat; Torok, Kathryn S.; Medsger, Thomas A.

    2010-01-01

    Objective. To develop and assess the psychometric properties of the Localized Scleroderma (LS) Skin Damage Index (LoSDI) and Physician Global Assessment of disease Damage (PGA-D). Methods. Damage was defined as irreversible/persistent changes (>6 months) due to previous active disease/complications of therapy. Eight rheumatologists assessed the importance of 17 variables in formulating the PGA-D/LoSDI. LS patients were evaluated by two rheumatologists using both tools to assess their psychometric properties. LoSDI was calculated by summing three scores for cutaneous features of damage [dermal atrophy (DAT), subcutaneous atrophy (SAT) and dyspigmentation (DP)] measured at 18 anatomic sites. Patient GA of disease severity (PtGA-S), Children's Dermatology Life Quality Index (CDLQI) and PGA-D were recorded at the time of each examination. Results. Thirty LS patients (112 lesions) and nine patient-visit pairs (18 lesions) were included for inter- and intra-rater reliability study. LoSDI and its domains DAT, SAT, DP and PGA-D demonstrated excellent inter- and intra-rater reliability (reliability coefficients 0.86–0.99 and 0.74–0.96, respectively). LoSDI correlated moderately with PGA-D and poorly with PtGA-S and CDLQI. PGA-D correlated moderately with PtGA-S, but poorly with CDLQI. Conclusions. To complete the LS Cutaneous Assessment Tool (LoSCAT), we developed and evaluated the psychometric properties of the LoSDI and PGA-D in addition to the LS Skin Severity Index (LoSSI). These instruments will facilitate evaluation of LS patients for individual patient management and clinical trials. LoSDI and PGA-D demonstrated excellent reliability and high validity. LoSCAT provides an improved understanding of LS natural history. Further study in a larger group of patients is needed to confirm these preliminary findings. PMID:20008472

  16. Interrater reliability among epilepsy centers: multicenter study of epilepsy surgery.

    PubMed

    Haut, Sheryl R; Berg, Anne T; Shinnar, Shlomo; Cohen, Hillel W; Bazil, Carl W; Sperling, Michael R; Langfitt, John T; Pacia, Steven V; Walczak, Thaddeus S; Spencer, Susan S

    2002-11-01

    To measure the interrater reliability of presurgical testing and surgical decisions among epilepsy centers. Seven centers participating in an ongoing, prospective multicenter study of resective epilepsy surgery agreed to conform to a detailed protocol regarding presurgical evaluation and surgery. To assess quality assurance, each center independently reviewed 21 randomly selected surgical cases for preoperative study lateralization and localization, and surgical decisions. Interrater reliability was assessed by using intraclass correlation coefficients (ICCs), validated for use with multiple raters, and calculated in a two-way random model based on absolute agreement. Agreement for ICC values: > or = 0.75, excellent; 0.60-0.74, good; 0.40-0.59, fair; < or = 0.39, poor. One center was excluded for missing data. Agreement was excellent for extracranial EEG lateralization (0.8039), magnetic resonance imaging (MRI) lateralization (0.9521) and localization (0.9130), Wada lateralization (0.9453), and intracranial EEG localization (0.7905). Agreement was good for extracranial EEG localization (0.7384) and neuropsychological testing lateralization (0.7178) and localization (0.6891). Consensus about the decision to perform intracranial monitoring was fair (0.5397), in part reflecting one center's tendency toward intracranial monitoring. Overall agreements on whether to perform surgery (0.8311) and specific surgery recommended (0.8164) were excellent. High interrater reliability among six epilepsy centers was present for interpretation of most components of presurgical testing. Although consensus for the decision to perform intracranial monitoring was only fair, agreements for the ultimate decision about resective surgery and specific choice of resection were excellent. We believe that this study demonstrates the feasibility of implementing multicenter protocols for neurologic management, especially those involving localization, as well as protocols combining study results with clinical decision making.

  17. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: III. Convolution and deconvolution.

    PubMed

    Langenbucher, Frieder

    2003-11-01

    Convolution and deconvolution are the classical in-vitro-in-vivo correlation tools to describe the relationship between input and weighting/response in a linear system, where input represents the drug release in vitro, weighting/response any body response in vivo. While functional treatment, e.g. in terms of polyexponential or Weibull distribution, is more appropriate for general survey or prediction, numerical algorithms are useful for treating actual experimental data. Deconvolution is not considered an algorithm by its own, but the inversion of a corresponding convolution. MS Excel is shown to be a useful tool for all these applications.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aita, J.F.; Keyes, J.W. Jr.

    Two cases of acute infantile hemiplegia are presented. The first case is a patient with moyamoya disease with excellent correlation between the brain scan findings and her clinical signs and symptoms and the carotid arteriogram. The second patient had occlusive cerebrovascular disease secondary to thromboemboli with excellent correlation between the brain scan findings and his clinical state and the neuropathologic examination. In both cases the static brain scans and the radionuclide angiogram were comparable to those reported in adults with cerebrovascular disease both in appearance and in temporal sequence. Radionuclide studies can be an important and reliable diagnostic tool inmore » the evaluation of acute infantile hemiplegia. (auth)« less

  19. Validation of a motion-robust 2D sequential technique for quantification of hepatic proton density fat fraction during free breathing.

    PubMed

    Pooler, B Dustin; Hernando, Diego; Ruby, Jeannine A; Ishii, Hiroshi; Shimakawa, Ann; Reeder, Scott B

    2018-04-17

    Current chemical-shift-encoded (CSE) MRI techniques for measuring hepatic proton density fat fraction (PDFF) are sensitive to motion artifacts. Initial validation of a motion-robust 2D-sequential CSE-MRI technique for quantification of hepatic PDFF. Phantom study and prospective in vivo cohort. Fifty adult patients (27 women, 23 men, mean age 57.2 years). 3D, 2D-interleaved, and 2D-sequential CSE-MRI acquisitions at 1.5T. Three CSE-MRI techniques (3D, 2D-interleaved, 2D-sequential) were performed in a PDFF phantom and in vivo. Reference standards were 3D CSE-MRI PDFF measurements for the phantom study and single-voxel MR spectroscopy hepatic PDFF measurements (MRS-PDFF) in vivo. In vivo hepatic MRI-PDFF measurements were performed during a single breath-hold (BH) and free breathing (FB), and were repeated by a second reader for the FB 2D-sequential sequence to assess interreader variability. Correlation plots to validate the 2D-sequential CSE-MRI against the phantom and in vivo reference standards. Bland-Altman analysis of FB versus BH CSE-MRI acquisitions to evaluate robustness to motion. Bland-Altman analysis to assess interreader variability. Phantom 2D-sequential CSE-MRI PDFF measurements demonstrated excellent agreement and correlation (R 2 > 0.99) with 3D CSE-MRI. In vivo, the mean (±SD) hepatic PDFF was 8.8 ± 8.7% (range 0.6-28.5%). Compared with BH acquisitions, FB hepatic PDFF measurements demonstrated bias of +0.15% for 2D-sequential compared with + 0.53% for 3D and +0.94% for 2D-interleaved. 95% limits of agreement (LOA) were narrower for 2D-sequential (±0.99%), compared with 3D (±3.72%) and 2D-interleaved (±3.10%). All CSE-MRI techniques had excellent correlation with MRS (R 2 > 0.97). The FB 2D-sequential acquisition demonstrated little interreader variability, with mean bias of +0.07% and 95% LOA of ± 1.53%. This motion-robust 2D-sequential CSE-MRI can accurately measure hepatic PDFF during free breathing in a patient population with a range of PDFF values of 0.6-28.5%, permitting accurate quantification of liver fat content without the need for suspended respiration. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  20. Monitoring sedation status over time in ICU patients: reliability and validity of the Richmond Agitation-Sedation Scale (RASS).

    PubMed

    Ely, E Wesley; Truman, Brenda; Shintani, Ayumi; Thomason, Jason W W; Wheeler, Arthur P; Gordon, Sharon; Francis, Joseph; Speroff, Theodore; Gautam, Shiva; Margolin, Richard; Sessler, Curtis N; Dittus, Robert S; Bernard, Gordon R

    2003-06-11

    Goal-directed delivery of sedative and analgesic medications is recommended as standard care in intensive care units (ICUs) because of the impact these medications have on ventilator weaning and ICU length of stay, but few of the available sedation scales have been appropriately tested for reliability and validity. To test the reliability and validity of the Richmond Agitation-Sedation Scale (RASS). Prospective cohort study. Adult medical and coronary ICUs of a university-based medical center. Thirty-eight medical ICU patients enrolled for reliability testing (46% receiving mechanical ventilation) from July 21, 1999, to September 7, 1999, and an independent cohort of 275 patients receiving mechanical ventilation were enrolled for validity testing from February 1, 2000, to May 3, 2001. Interrater reliability of the RASS, Glasgow Coma Scale (GCS), and Ramsay Scale (RS); validity of the RASS correlated with reference standard ratings, assessments of content of consciousness, GCS scores, doses of sedatives and analgesics, and bispectral electroencephalography. In 290-paired observations by nurses, results of both the RASS and RS demonstrated excellent interrater reliability (weighted kappa, 0.91 and 0.94, respectively), which were both superior to the GCS (weighted kappa, 0.64; P<.001 for both comparisons). Criterion validity was tested in 411-paired observations in the first 96 patients of the validation cohort, in whom the RASS showed significant differences between levels of consciousness (P<.001 for all) and correctly identified fluctuations within patients over time (P<.001). In addition, 5 methods were used to test the construct validity of the RASS, including correlation with an attention screening examination (r = 0.78, P<.001), GCS scores (r = 0.91, P<.001), quantity of different psychoactive medication dosages 8 hours prior to assessment (eg, lorazepam: r = - 0.31, P<.001), successful extubation (P =.07), and bispectral electroencephalography (r = 0.63, P<.001). Face validity was demonstrated via a survey of 26 critical care nurses, which the results showed that 92% agreed or strongly agreed with the RASS scoring scheme, and 81% agreed or strongly agreed that the instrument provided a consensus for goal-directed delivery of medications. The RASS demonstrated excellent interrater reliability and criterion, construct, and face validity. This is the first sedation scale to be validated for its ability to detect changes in sedation status over consecutive days of ICU care, against constructs of level of consciousness and delirium, and correlated with the administered dose of sedative and analgesic medications.

  1. Validation of a Dry Model for Assessing the Performance of Arthroscopic Hip Labral Repair.

    PubMed

    Phillips, Lisa; Cheung, Jeffrey J H; Whelan, Daniel B; Murnaghan, Michael Lucas; Chahal, Jas; Theodoropoulos, John; Ogilvie-Harris, Darrell; Macniven, Ian; Dwyer, Tim

    2017-07-01

    Arthroscopic hip labral repair is a technically challenging and demanding surgical technique with a steep learning curve. Arthroscopic simulation allows trainees to develop these skills in a safe environment. The purpose of this study was to evaluate the use of a combination of assessment ratings for the performance of arthroscopic hip labral repair on a dry model. Cross-sectional study; Level of evidence, 3. A total of 47 participants including orthopaedic surgery residents (n = 37), sports medicine fellows (n = 5), and staff surgeons (n = 5) performed arthroscopic hip labral repair on a dry model. Prior arthroscopic experience was noted. Participants were evaluated by 2 orthopaedic surgeons using a task-specific checklist, the Arthroscopic Surgical Skill Evaluation Tool (ASSET), task completion time, and a final global rating scale. All procedures were video-recorded and scored by an orthopaedic fellow blinded to the level of training of each participant. The internal consistency/reliability (Cronbach alpha) using the total ASSET score for the procedure was high (intraclass correlation coefficient > 0.9). One-way analysis of variance for the total ASSET score demonstrated a difference between participants based on the level of training ( F 3,43 = 27.8, P < .001). A good correlation was seen between the ASSET score and previous exposure to arthroscopic procedures ( r = 0.52-0.73, P < .001). The interrater reliability for the ASSET score was excellent (>0.9). The results of this study demonstrate that the use of dry models to assess the performance of arthroscopic hip labral repair by trainees is both valid and reliable. Further research will be required to demonstrate a correlation with performance on cadaveric specimens or in the operating room.

  2. The salivary β-HEX A% index as an excellent marker of periodontitis in smoking alcohol-dependent persons.

    PubMed

    Waszkiewicz, Napoleon; Zalewska-Szajda, Beata; Chojnowska, Sylwia; Szajda, Sławomir Dariusz; Zalewska, Anna; Konarzewska, Beata; Szulc, Agata; Wojtulewska-Supron, Aleksandra; Kępka, Alina; Knaś, Małgorzata; Ładny, Jerzy Robert; Milewski, Robert; Zwierz, Krzysztof

    2013-01-01

    Severe periodontitis leading to tooth loss is found in 5-15% of most populations worldwide. The applicability of salivary β -hexosaminidase (β-HEX A%, percentage of β-HEX A isoenzyme to total β-HEX) and β-HEX B% (β-HEX B/β-HEX) indexes was investigated as a possible marker of periodontitis. Thirty three alcohol-dependent smokers (AS) and 32 healthy controls (C) were enrolled in the study. The activity of β-HEX was measured spectrophotometrically. β-HEX A% was significantly higher and β-HEX B% was lower in AS than in C group. We found a significant correlation between β-HEX A% and gingival index (GI) and an inverse correlation between β-HEX A% and salivary flow (SF), in all groups. Salivary β-HEX A% index in smoking alcoholics at 0.23 had excellent sensitivity (96%) and specificity (91%); the AUC for β-HEX A% was high (0.937). There were no correlations between amount/duration-time of alcohol drinking/smoking and β-HEX A% or β-HEX B%. We found significant correlations between the time period of denture wearing and GI, papilla bleeding index (PBI), and decayed missing filled teeth index (DMFT) and between GI and the amount of smoked cigarettes per day. Bad periodontal state was most likely due to the nicotine dependence. Salivary β-HEX A% is a promising excellent marker for the diagnosis of periodontitis.

  3. NIH Toolbox Cognition Battery (NIHTB-CB): list sorting test to measure working memory.

    PubMed

    Tulsky, David S; Carlozzi, Noelle; Chiaravalloti, Nancy D; Beaumont, Jennifer L; Kisala, Pamela A; Mungas, Dan; Conway, Kevin; Gershon, Richard

    2014-07-01

    The List Sorting Working Memory Test was designed to assess working memory (WM) as part of the NIH Toolbox Cognition Battery. List Sorting is a sequencing task requiring children and adults to sort and sequence stimuli that are presented visually and auditorily. Validation data are presented for 268 participants ages 20 to 85 years. A subset of participants (N=89) was retested 7 to 21 days later. As expected, the List Sorting Test had moderately high correlations with other measures of working memory and executive functioning (convergent validity) but a low correlation with a test of receptive vocabulary (discriminant validity). Furthermore, List Sorting demonstrates expected changes over the age span and has excellent test-retest reliability. Collectively, these results provide initial support for the construct validity of the List Sorting Working Memory Measure as a measure of working memory. However, the relationship between the List Sorting Test and general executive function has yet to be determined.

  4. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    PubMed Central

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.

  5. Bell Inequality, Einstein-Podolsky-Rosen Steering, and Quantum Metrology with Spinor Bose-Einstein Condensates.

    PubMed

    Wasak, Tomasz; Chwedeńczuk, Jan

    2018-04-06

    We propose an experiment, where the Bell inequality is violated in a many-body system of massive particles. The source of correlated atoms is a spinor F=1 Bose-Einstein condensate residing in an optical lattice. We characterize the complete procedure-the local operations, the measurements, and the inequality-necessary to run the Bell test. We show how the degree of violation of the Bell inequality depends on the strengths of the two-body correlations and on the number of scattered pairs. We show that the system can be used to demonstrate the Einstein-Podolsky-Rosen paradox. Also, the scattered pairs are an excellent many-body resource for the quantum-enhanced metrology. Our results apply to any multimode system where the spin-changing collision drives the scattering into separate regions. The presented inquiry shows that such a system is versatile as it can be used for the tests of nonlocality, quantum metrology, and quantum information.

  6. Interaction Enthalpy of Side Chain and Backbone Amides in Polyglutamine Solution Monomers and Fibrils.

    PubMed

    Punihaole, David; Jakubek, Ryan S; Workman, Riley J; Asher, Sanford A

    2018-04-19

    We determined an empirical correlation that relates the amide I vibrational band frequencies of the glutamine (Q) side chain to the strength of hydrogen bonding, van der Waals, and Lewis acid-base interactions of its primary amide carbonyl. We used this correlation to determine the Q side chain carbonyl interaction enthalpy (Δ H int ) in monomeric and amyloid-like fibril conformations of D 2 Q 10 K 2 (Q10). We independently verified these Δ H int values through molecular dynamics simulations that showed excellent agreement with experiments. We found that side chain-side chain and side chain-peptide backbone interactions in fibrils and monomers are more enthalpically favorable than are Q side chain-water interactions. Q10 fibrils also showed a more favorable Δ H int for side chain-side chain interactions compared to backbone-backbone interactions. This work experimentally demonstrates that interamide side chain interactions are important in the formation and stabilization of polyQ fibrils.

  7. Validity of the Nintendo Wii® balance board for the assessment of standing balance in Parkinson's disease.

    PubMed

    Holmes, Jeffrey D; Jenkins, Mary E; Johnson, Andrew M; Hunt, Michael A; Clark, Ross A

    2013-04-01

    Impaired postural stability places individuals with Parkinson's at an increased risk for falls. Given the high incidence of fall-related injuries within this population, ongoing assessment of postural stability is important. To evaluate the validity of the Nintendo Wii(®) balance board as a measurement tool for the assessment of postural stability in individuals with Parkinson's. Twenty individuals with Parkinson's participated. Subjects completed testing on two balance tasks with eyes open and closed on a Wii(®) balance board and biomechanical force platform. Bland-Altman plots and a two-way, random-effects, single measure intraclass correlation coefficient model were used to assess concurrent validity of centre-of-pressure data. Concurrent validity was demonstrated to be excellent across balance tasks (intraclass correlation coefficients = 0.96, 0.98, 0.92, 0.94). This study suggests that the Wii(®) balance board is a valid tool for the quantification of postural stability among individuals with Parkinson's.

  8. Bell Inequality, Einstein-Podolsky-Rosen Steering, and Quantum Metrology with Spinor Bose-Einstein Condensates

    NASA Astrophysics Data System (ADS)

    Wasak, Tomasz; Chwedeńczuk, Jan

    2018-04-01

    We propose an experiment, where the Bell inequality is violated in a many-body system of massive particles. The source of correlated atoms is a spinor F =1 Bose-Einstein condensate residing in an optical lattice. We characterize the complete procedure—the local operations, the measurements, and the inequality—necessary to run the Bell test. We show how the degree of violation of the Bell inequality depends on the strengths of the two-body correlations and on the number of scattered pairs. We show that the system can be used to demonstrate the Einstein-Podolsky-Rosen paradox. Also, the scattered pairs are an excellent many-body resource for the quantum-enhanced metrology. Our results apply to any multimode system where the spin-changing collision drives the scattering into separate regions. The presented inquiry shows that such a system is versatile as it can be used for the tests of nonlocality, quantum metrology, and quantum information.

  9. NIH Toolbox Cognition Battery (NIHTB-CB): The List Sorting Test to Measure Working Memory

    PubMed Central

    Tulsky, David S.; Carlozzi, Noelle; Chiaravalloti, Nancy D.; Beaumont, Jennifer L.; Kisala, Pamela A.; Mungas, Dan; Conway, Kevin; Gershon, Richard

    2015-01-01

    The List Sorting Working Memory Test was designed to assess working memory (WM) as part of the NIH Toolbox Cognition Battery. List Sorting is a sequencing task requiring children and adults to sort and sequence stimuli that are presented visually and auditorily. Validation data are presented for 268 participants ages 20 to 85 years. A subset of participants (N=89) was retested 7 to 21 days later. As expected, the List Sorting Test had moderately high correlations with other measures of working memory and executive functioning (convergent validity) but a low correlation with a test of receptive vocabulary (discriminant validity). Furthermore, List Sorting demonstrates expected changes over the age span and has excellent test-retest reliability. Collectively, these results provide initial support the construct validity of the List Sorting Working Memory Measure as a measure of working memory. However, the relation between the List Sorting Test and general executive function has yet to be determined. PMID:24959983

  10. Improving Photometry and Stellar Signal Preservation with Pixel-Level Systematic Error Correction

    NASA Technical Reports Server (NTRS)

    Kolodzijczak, Jeffrey J.; Smith, Jeffrey C.; Jenkins, Jon M.

    2013-01-01

    The Kepler Mission has demonstrated that excellent stellar photometric performance can be achieved using apertures constructed from optimally selected CCD pixels. The clever methods used to correct for systematic errors, while very successful, still have some limitations in their ability to extract long-term trends in stellar flux. They also leave poorly correlated bias sources, such as drifting moiré pattern, uncorrected. We will illustrate several approaches where applying systematic error correction algorithms to the pixel time series, rather than the co-added raw flux time series, provide significant advantages. Examples include, spatially localized determination of time varying moiré pattern biases, greater sensitivity to radiation-induced pixel sensitivity drops (SPSDs), improved precision of co-trending basis vectors (CBV), and a means of distinguishing the stellar variability from co-trending terms even when they are correlated. For the last item, the approach enables physical interpretation of appropriately scaled coefficients derived in the fit of pixel time series to the CBV as linear combinations of various spatial derivatives of the pixel response function (PRF). We demonstrate that the residuals of a fit of soderived pixel coefficients to various PRF-related components can be deterministically interpreted in terms of physically meaningful quantities, such as the component of the stellar flux time series which is correlated with the CBV, as well as, relative pixel gain, proper motion and parallax. The approach also enables us to parameterize and assess the limiting factors in the uncertainties in these quantities.

  11. Linear System of Equations, Matrix Inversion, and Linear Programming Using MS Excel

    ERIC Educational Resources Information Center

    El-Gebeily, M.; Yushau, B.

    2008-01-01

    In this note, we demonstrate with illustrations two different ways that MS Excel can be used to solve Linear Systems of Equation, Linear Programming Problems, and Matrix Inversion Problems. The advantage of using MS Excel is its availability and transparency (the user is responsible for most of the details of how a problem is solved). Further, we…

  12. A Comparison of Organizational Climate and Nurses' Intention to Leave Among Excellence Awarded Hospitals and Other Hospitals in 2013.

    PubMed

    Mohamadzadeh Nojehdehi, Maryam; Ashgholi Farahani, Mansoureh; Rafii, Forough; Bahrani, Nasser

    2015-05-01

    Human resource is the most important factor of performance, success and better revelation of excellence goals of each organization. By performing excellence plan, healthcare organizations improve their organizational climate and play a valuable role in retaining nurses and improving the quality of their services to patients. The aim of this study was to compare hospital organizational climate and intention to leave among working nurses in hospitals performing the excellence plan and other hospitals of Tehran University of Medical Sciences. This was a cross-sectional descriptive comparison study. Its population included 248 nurses of the hospitals performing the excellence plan and other hospitals of Tehran University of Medical Sciences in Iran selected by random sampling. The used instrument had three parts: the first part was related to personal characteristics, the second part was the Munn's organizational climate questionnaire and the third part was Hinshaw's questionnaire of "anticipated turnover scale". Data was analyzed using SPSS software, version 17 and indices of descriptive statistics and inferential statistics. The results of the mean and standard deviation for organizational climate and intention to leave in both performing and non-performing hospitals of the organizational excellence plan were respectively (65.28 ± 19.31 and 56.42 ± 21.36) and (33.64 ± 5.58 and 35.59 ± 4.94). Independent T test revealed a significant difference between the mean scores for organizational climate in both performing and non-performing hospitals, and also a significant difference between the mean scores for intention to leave in both performing and non-performing hospitals (P = 0.004). Moreover, Pearson Correlation test showed a reverse significant correlation between organizational climate and intention to leave in performing hospitals of the organizational excellence plan (r = -0.337) and non-performing hospitals (r = -0.282) (P = 0.001). Performing quality improvement pattern such as organization's excellence plan improves organizational climate of healthcare sectors, it can reduce nurses' intentions to leave and retain human resources.

  13. Analysis of SMA Hybrid Composite Structures in MSC.Nastran and ABAQUS

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.; Patel, Hemant D.

    2005-01-01

    A thermoelastic constitutive model for shape memory alloy (SMA) actuators and SMA hybrid composite (SMAHC) structures was recently implemented in the commercial finite element codes MSC.Nastran and ABAQUS. The model may be easily implemented in any code that has the capability for analysis of laminated composite structures with temperature dependent material properties. The model is also relatively easy to use and requires input of only fundamental engineering properties. A brief description of the model is presented, followed by discussion of implementation and usage in the commercial codes. Results are presented from static and dynamic analysis of SMAHC beams of two types; a beam clamped at each end and a cantilever beam. Nonlinear static (post-buckling) and random response analyses are demonstrated for the first specimen. Static deflection (shape) control is demonstrated for the cantilever beam. Approaches for modeling SMAHC material systems with embedded SMA in ribbon and small round wire product forms are demonstrated and compared. The results from the commercial codes are compared to those from a research code as validation of the commercial implementations; excellent correlation is achieved in all cases.

  14. Analysis of SMA Hybrid Composite Structures using Commercial Codes

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.; Patel, Hemant D.

    2004-01-01

    A thermomechanical model for shape memory alloy (SMA) actuators and SMA hybrid composite (SMAHC) structures has been recently implemented in the commercial finite element codes MSC.Nastran and ABAQUS. The model may be easily implemented in any code that has the capability for analysis of laminated composite structures with temperature dependent material properties. The model is also relatively easy to use and requires input of only fundamental engineering properties. A brief description of the model is presented, followed by discussion of implementation and usage in the commercial codes. Results are presented from static and dynamic analysis of SMAHC beams of two types; a beam clamped at each end and a cantilevered beam. Nonlinear static (post-buckling) and random response analyses are demonstrated for the first specimen. Static deflection (shape) control is demonstrated for the cantilevered beam. Approaches for modeling SMAHC material systems with embedded SMA in ribbon and small round wire product forms are demonstrated and compared. The results from the commercial codes are compared to those from a research code as validation of the commercial implementations; excellent correlation is achieved in all cases.

  15. 3D photography is as accurate as digital planimetry tracing in determining burn wound area.

    PubMed

    Stockton, K A; McMillan, C M; Storey, K J; David, M C; Kimble, R M

    2015-02-01

    In the paediatric population careful attention needs to be made concerning techniques utilised for wound assessment to minimise discomfort and stress to the child. To investigate whether 3D photography is a valid measure of burn wound area in children compared to the current clinical gold standard method of digital planimetry using Visitrak™. Twenty-five children presenting to the Stuart Pegg Paediatric Burn Centre for burn dressing change following acute burn injury were included in the study. Burn wound area measurement was undertaken using both digital planimetry (Visitrak™ system) and 3D camera analysis. Inter-rater reliability of the 3D camera software was determined by three investigators independently assessing the burn wound area. A comparison of wound area was assessed using intraclass correlation co-efficients (ICC) which demonstrated excellent agreement 0.994 (CI 0.986, 0.997). Inter-rater reliability measured using ICC 0.989 (95% CI 0.979, 0.995) demonstrated excellent inter-rater reliability. Time taken to map the wound was significantly quicker using the camera at bedside compared to Visitrak™ 14.68 (7.00)s versus 36.84 (23.51)s (p<0.001). In contrast, analysing wound area was significantly quicker using the Visitrak™ tablet compared to Dermapix(®) software for the 3D Images 31.36 (19.67)s versus 179.48 (56.86)s (p<0.001). This study demonstrates that images taken with the 3D LifeViz™ camera and assessed with Dermapix(®) software is a reliable method for wound area assessment in the acute paediatric burn setting. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  16. The Kibble-Zurek mechanism in phase transitions of non-equilibrium systems

    NASA Astrophysics Data System (ADS)

    Cheung, Hil F. H.; Patil, Yogesh S.; Date, Aditya G.; Vengalattore, Mukund

    2017-04-01

    We experimentally realize a driven-dissipative phase transition using a mechanical parametric amplifier to demonstrate key signatures of a second order phase transition, including a point where the susceptibilities and relaxation time scales diverge, and where the system exhibits a spontaneous breaking of symmetry. Though reminiscent of conventional equilibrium phase transitions, it is unclear if such driven-dissipative phase transitions are amenable to the conventional Landau-Ginsburg-Wilson paradigm, which relies on concepts of scale invariance and universality, and recent work has shown that such phase transitions can indeed lie beyond such conventional universality classes. By quenching the system past the critical point, we investigate the dynamics of the emergent ordered phase and find that our measurements are in excellent agreement with the Kibble-Zurek mechanism. In addition to verifying the Kibble-Zurek hypothesis in driven-dissipative phase transitions for the first time, we also demonstrate that the measured critical exponents accurately reflect the interplay between intrinsic coherent dynamics and environmental correlations, showing a clear departure from mean field exponents in the case of non-Markovian system-bath interactions. We further discuss how reservoir engineering and the imposition of artificial environmental correlations can result in the stabilization of novel many-body quantum phases and aid in the creation of exotic non-equilibrium states of matter.

  17. Characterization of integrated optical CD for process control

    NASA Astrophysics Data System (ADS)

    Yu, Jackie; Uchida, Junichi; van Dommelen, Youri; Carpaij, Rene; Cheng, Shaunee; Pollentier, Ivan; Viswanathan, Anita; Lane, Lawrence; Barry, Kelly A.; Jakatdar, Nickhil

    2004-05-01

    The accurate measurement of CD (critical dimension) and its application to inline process control are key challenges for high yield and OEE (overall equipment efficiency) in semiconductor production. CD-SEM metrology, although providing the resolution necessary for CD evaluation, suffers from the well-known effect of resist shrinkage, making accuracy and stability of the measurements an issue. For sub-100 nm in-line process control, where accuracy and stability as well as speed are required, CD-SEM metrology faces serious limitations. In contrast, scatterometry, using broadband optical spectra taken from grating structures, does not suffer from such limitations. This technology is non-destructive and, in addition to CD, provides profile information and film thickness in a single measurement. Using Timbre's Optical Digital Profililometry (ODP) technology, we characterized the Process Window, using a iODP101 integrated optical CD metrology into a TEL Clean Track at IMEC. We demonstrate the Optical CD's high sensitivity to process change and its insensitivity to measurement noise. We demonstrate the validity of ODP modeling by showing its accurate response to known process changes built into the evaluation and its excellent correlation to CD-SEM. We will further discuss the intrinsic Optical CD metrology factors that affect the tool precision, accuracy and its correlation to CD-SEM.

  18. Profiling microbial community in a watershed heavily contaminated by an active antimony (Sb) mine in Southwest China.

    PubMed

    Sun, Weimin; Xiao, Enzong; Dong, Yiran; Tang, Song; Krumins, Valdis; Ning, Zengping; Sun, Min; Zhao, Yanlong; Wu, Shiliang; Xiao, Tangfu

    2016-04-15

    Located in Southwest China, the Chahe watershed has been severely contaminated by upstream active antimony (Sb) mines. The extremely high concentrations of Sb make the Chahe watershed an excellent model to elucidate the response of indigenous microbial activities within a severe Sb-contaminated environment. In this study, water and surface sediments from six locations in the Chahe watershed with different levels of Sb contamination were analyzed. Illumina sequencing of 16S rRNA amplicons revealed more than 40 phyla from the domain Bacteria and 2 phyla from the domain Archaea. Sequences assigned to the genera Flavobacterium, Sulfuricurvum, Halomonas, Shewanella, Lactobacillus, Acinetobacter, and Geobacter demonstrated high relative abundances in all sequencing libraries. Spearman's rank correlations indicated that a number of microbial phylotypes were positively correlated with different speciation of Sb, suggesting potential roles of these phylotypes in microbial Sb cycling. Canonical correspondence analysis further demonstrated that geochemical parameters, including water temperature, pH, total Fe, sulfate, aqueous Sb, and Eh, significantly structured the overall microbial community in Chahe watershed samples. Our findings offer a direct and reliable reference to the diversity of microbial communities in the presence of extremely high Sb concentrations, and may have potential implications for in situ bioremediation strategies of Sb contaminated sites. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Boundary Layer Transition in the Leading Edge Region of a Swept Cylinder in High Speed Flow

    NASA Technical Reports Server (NTRS)

    Coleman, Colin P.

    1998-01-01

    Experiments were conducted on a 76 degree swept cylinder to establish the behavior of the attachment line transition process in a low-disturbance level, Mach number 1.6 flow. For a near adiabatic wall condition, the attachment-line boundary layer remained laminar up to the highest attainable Reynolds number. The attachment-line boundary layer transition under the influence of trip wires depended on wind tunnel disturbance level, and a transition onset condition for this flow is established. Internal heating raised the surface temperature of the attachment line to induce boundary layer instabilities. This was demonstrated experimentally for the first time and the frequencies of the most amplified disturbances were determined over a range of temperature settings. Results were in excellent agreement to those predicted by a linear stability code, and provide the first experimental verification of theory. Transition onset along the heated attachment line at an R-bar of 800 under quiet tunnel conditions was found to correlate with an N factor of 13.2. Increased tunnel disturbance levels caused the transition onset to occur at lower cylinder surface temperatures and was found to correlate with an approximate N factor of 1 1.9, so demonstrating that the attachment-line boundary layer is receptive to increases in the tunnel disturbance level.

  20. The Computerized Perceptual Motor Skills Assessment: A new visual perceptual motor skills evaluation tool for children in early elementary grades.

    PubMed

    Howe, Tsu-Hsin; Chen, Hao-Ling; Lee, Candy Chieh; Chen, Ying-Dar; Wang, Tien-Ni

    2017-10-01

    Visual perceptual motor skills have been proposed as underlying courses of handwriting difficulties. However, there is no evaluation tool currently available to assess these skills comprehensively and to serve as a sensitive measure. The purpose of this study was to validate the Computerized Perceptual Motor Skills Assessment (CPMSA), a newly developed evaluation tool for children in early elementary grades. Its test-retest reliability, concurrent validity, discriminant validity, and responsiveness were examined in 43 typically developing children and 26 children with handwriting difficulty. The CPMSA demonstrated excellent reliability across all subtests with intra-class correlation coefficients (ICCs)≥0.80. Significant moderate correlations between the domains of the CPMSA and corresponding gold standards including Beery VMI, the TVPS-3, and the eye-hand coordination subtest of the DTVP-2 demonstrated good concurrent validity. In addition, the CPMSA showed evidence of discriminant validity in samples of children with and without handwriting difficulty. This article provides evidence in support of the CPMSA. The CPMSA is a reliable, valid, and promising measure of visual perceptual motor skills for children in early elementary grades. Directions for future study and improvements to the assessment are discussed. Copyright © 2017. Published by Elsevier Ltd.

  1. Effect of structure and morphology on thermal and electrical properties of polycarbonate film capacitors

    NASA Astrophysics Data System (ADS)

    Yen, S. P. S.; Lewis, C. R.

    Research is reported to identify polycarbonate (PC) film characteristics and fabrication procedures which extend the reliable performance range of PC capacitors to 125 C without derating, and establish quality control techniques and transfer technology to US PC film manufacturers. The approach chosen to solve these problems was to develop techniques for fabricating biaxially oriented (BX) 2 microns or thinner PC film with a low dissipation factor up to 140 C; isotropic dimensional stability; high crystallinity; and high voltage breakdown strength. The PC film structure and morphology was then correlated to thermal and electrical capacitor behavior. Analytical techniques were developed to monitor film quality during capacitor fabrication, and as a result, excellent performance was demonstrated during initial capacitor testing.

  2. Buckling Testing and Analysis of Space Shuttle Solid Rocket Motor Cylinders

    NASA Technical Reports Server (NTRS)

    Weidner, Thomas J.; Larsen, David V.; McCool, Alex (Technical Monitor)

    2002-01-01

    A series of full-scale buckling tests were performed on the space shuttle Reusable Solid Rocket Motor (RSRM) cylinders. The tests were performed to determine the buckling capability of the cylinders and to provide data for analytical comparison. A nonlinear ANSYS Finite Element Analysis (FEA) model was used to represent and evaluate the testing. Analytical results demonstrated excellent correlation to test results, predicting the failure load within 5%. The analytical value was on the conservative side, predicting a lower failure load than was applied to the test. The resulting study and analysis indicated the important parameters for FEA to accurately predict buckling failure. The resulting method was subsequently used to establish the pre-launch buckling capability of the space shuttle system.

  3. Monitoring of cyclosporine concentrations by using dry blood-spot samples.

    PubMed

    Mee, A V; Wong, P Y; Sun, C; Oei, L; Elliott, S; Naik, N; Joaquin, B; Uchimaru, D

    1991-01-01

    We modified the Incstar Cyclo Trac SP kit to enable its use with dry blood-spots on filter paper. The recovery ranged from 92 to 106%. Dilution studies have shown excellent linearity and parallelism throughout the range of the assay. Precision is demonstrated by within-assay CV's of 6.6 and 4.3% at 96 and 342 micrograms/L respectively and between-assay CV's of 9.1 and 7.0% at 138 and 506 micrograms/L respectively. A comparison study (n = 209) with whole blood assay gave a correlation coefficient of 0.97, a slope of 1.04, and an intercept of 13.2. Whole blood and dry blood-spot cyclosporine assays on heart, kidney, liver, and lung transplants were also compared.

  4. Modified schirmer test--a screening tool for xerostomia among subjects on antidepressants.

    PubMed

    Kumar, Nerella Narendra; Panchaksharappa, Mamatha Gowda; Annigeri, Rajeshwari G

    2014-08-01

    The aim of the present study is to assess salivary flow rate in the subjects who were on antidepressant medications and its comparison with healthy controls and assessment of unstimulated salivary flow rate by modified Schirmer test (MST) and volumetric method (spitting method) for evaluation of xerostomia and whether any correlation exists between two methods. Thirty subjects who were on antidepressants were divided into two groups: tricyclic antidepressants (TCA) and selective sertonin reuptake inhibitors (SSRI) of 15 each, compared with 30 age and gender matched controls. Unstimulated salivary flow rate was measured by both MST and spitting method. The unstimulated salivary flow rate measured by MST at the end of 3rd minute was 13.7 ± 10.08, 19.86 ± 8.95 and 31.0 ± 5.4 mm and by spitting method was 0.12 ± 0.07, 0.19 ± 0.10 and 0.30 ± 0.75 ml/min in TCA, SSRI and controls respectively (p<0.001). The Pearson correlation coefficient of r=0.85 shows excellent correlation between the two screening tests. Sensitivity and Specificity of MST was 90.9% and 31.5%. Salivary flow rate was less in antidepressant subjects when compared to the healthy controls. Results of the present study showed an excellent correlation excellent correlation between the two screening tests which suggests that MST can be routinely used as chair-side screening tool to evaluate hyposalivation which is time saving, patient friendly and specific of salivary secretions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Real-time assessment of perioperative behaviors in children and parents: development and validation of the perioperative adult child behavioral interaction scale.

    PubMed

    Sadhasivam, Senthilkumar; Cohen, Lindsey L; Hosu, Liana; Gorman, Kristin L; Wang, Yu; Nick, Todd G; Jou, Jing Fang; Samol, Nancy; Szabova, Alexandra; Hagerman, Nancy; Hein, Elizabeth; Boat, Anne; Varughese, Anna; Kurth, Charles Dean; Willging, J Paul; Gunter, Joel B

    2010-04-01

    Behavior in response to distressful events during outpatient pediatric surgery can contribute to postoperative maladaptive behaviors, such as temper tantrums, nightmares, bed-wetting, and attention seeking. Currently available perioperative behavioral assessment tools have limited utility in guiding interventions to ameliorate maladaptive behaviors because they cannot be used in real time, are only intended to be used during 1 phase of the experience (e.g., perioperative), or provide only a static assessment of the child (e.g., level of anxiety). A simple, reliable, real-time tool is needed to appropriately identify children and parents whose behaviors in response to distressful events at any point in the perioperative continuum could benefit from timely behavioral intervention. Our specific aims were to (1) refine the Perioperative Adult Child Behavioral Interaction Scale (PACBIS) to improve its reliability in identifying perioperative behaviors and (2) validate the refined PACBIS against several established instruments. The PACBIS was used to assess the perioperative behaviors of 89 children aged 3 to 12 years presenting for adenotonsillectomy and their parents. Assessments using the PACBIS were made during perioperative events likely to prove distressing to children and/or parents (perioperative measurement of blood pressure, induction of anesthesia, and removal of the IV catheter before discharge). Static measurements of perioperative anxiety and behavioral compliance during anesthetic induction were made using the modified Yale Preoperative Anxiety Scale and the Induction Compliance Checklist (ICC). Each event was videotaped for later scoring using the Child-Adult Medical Procedure Interaction Scale-Short Form (CAMPIS-SF) and Observational Scale of Behavioral Distress (OSBD). Interrater reliability using linear weighted kappa (kappa(w)) and multiple validations using Spearman correlation coefficients were analyzed. The PACBIS demonstrated good to excellent interrater reliability, with kappa(w) ranging from 0.62 to 0.94. The Child Coping and Child Distress subscores of the PACBIS demonstrated strong concurrent correlations with the modified Yale Preoperative Anxiety Scale, ICC, CAMPIS-SF, and OSBD. The Parent Positive subscore of the PACBIS correlated strongly with the CAMPIS-SF and OSBD, whereas the Parent Negative subscore showed significant correlation with the ICC. The PACBIS has strong construct and predictive validities. The PACBIS is a simple, easy to use, real-time instrument to evaluate perioperative behaviors of both children and parents. It has good to excellent interrater reliability and strong concurrent validity against currently accepted scales. The PACBIS offers a means to identify maladaptive child or parental behaviors in real time, making it possible to intervene to modify such behaviors in a timely fashion.

  6. Expression of Bcl-2, Melan A and HMB-45 in Dysplastic Nevi.

    PubMed

    Patrascu, Oana Maria; Costache, Mariana; Dumitru, Adrian Vasile; Mehotin, Corina Nicoleta; Sajin, Maria; Lazaroiu, Anca Mihaela

    2016-03-01

    From the first recognition of dysplastic nevi as a pathology per se, many debates have been raised and many histological and immunohistological studies have been conducted in order to establish the true significance of these lesions. Therefore, the aim of this study was to establish if there is a correlation between HMB-45, Melan A and Bcl-2 expression and the grade of dysplasia, as well as between the marker's staining patterns. Ten dysplastic nevi from six female patients were selected and their histological features (size, dysplasia), as well as the immunohistological staining patterns, were studied (HMB-45, Melan A, Bcl-2). The Pearson correlation coefficient and regression was calculated with Windows Excel Data Analysis. We demonstrated that there was a notable correlation between the dysplasia and the size of the lesions (r(8)= 0.62 with p-value= 0.052), and also between Melan A and Bcl-2 (a r(6)= 0.73, p<0.05), but we did not obtain a statistically significant correlation between other features (p>0.05). We can affirm, at least in our cases, there is a correlation between the grade of dysplasia and the size of the lesion, and also, that there is a correlation between Melan A and Bcl-2 staining, explained by MITF gene. These results were only partial concordant with those in other studies, therefore a larger number of cases is recommended to be further analyzed in order to clearly draw a conclusion.

  7. Evidence of three-body correlation functions in Rb+ and Sr2+ acetonitrile solutions

    NASA Astrophysics Data System (ADS)

    D'Angelo, P.; Pavel, N. V.

    1999-09-01

    The local structure of Sr2+ and Rb+ ions in acetonitrile has been investigated by x-ray absorption spectroscopy (XAS) and molecular dynamics simulations. The extended x-ray absorption fine structure above the Sr and Rb K edges has been interpreted in the framework of multiple scattering (MS) formalism and, for the first time, clear evidence of MS contributions has been found in noncomplexing ion solutions. Molecular dynamics has been used to generate the partial pair and triangular distribution functions from which model χ(k) signals have been constructed. The Sr2+ and Rb+ acetonitrile pair distribution functions show very sharp and well-defined first peaks indicating the presence of a well organized first solvation shell. Most of the linear acetonitrile molecules have been found to be distributed like hedgehog spines around the Sr2+ and Rb+ ions. The presence of three-body correlations has been singled out by the existence of well-defined peaks in the triangular configurations. Excellent agreement has been found between the theoretical and experimental data enforcing the reliability of the interatomic potentials used in the simulations. These results demonstrate the ability of the XAS technique in probing the higher-order correlation functions in solution.

  8. A Dynamic Network Model to Explain the Development of Excellent Human Performance

    PubMed Central

    Den Hartigh, Ruud J. R.; Van Dijk, Marijn W. G.; Steenbeek, Henderien W.; Van Geert, Paul L. C.

    2016-01-01

    Across different domains, from sports to science, some individuals accomplish excellent levels of performance. For over 150 years, researchers have debated the roles of specific nature and nurture components to develop excellence. In this article, we argue that the key to excellence does not reside in specific underlying components, but rather in the ongoing interactions among the components. We propose that excellence emerges out of dynamic networks consisting of idiosyncratic mixtures of interacting components such as genetic endowment, motivation, practice, and coaching. Using computer simulations we demonstrate that the dynamic network model accurately predicts typical properties of excellence reported in the literature, such as the idiosyncratic developmental trajectories leading to excellence and the highly skewed distributions of productivity present in virtually any achievement domain. Based on this novel theoretical perspective on excellent human performance, this article concludes by suggesting policy implications and directions for future research. PMID:27148140

  9. Development and Demonstration of an Aerial Imagery Assessment Method to Monitor Changes in Restored Stream Condition

    NASA Astrophysics Data System (ADS)

    Fong, L. S.; Ambrose, R. F.

    2017-12-01

    Remote sensing is an excellent way to assess the changing condition of streams and wetlands. Several studies have measured large-scale changes in riparian condition indicators, but few have remotely applied multi-metric assessments on a finer scale to measure changes, such as those caused by restoration, in the condition of small riparian areas. We developed an aerial imagery assessment method (AIAM) that combines landscape, hydrology, and vegetation observations into one index describing overall ecological condition of non-confined streams. Verification of AIAM demonstrated that sites in good condition (as assessed on-site by the California Rapid Assessment Method) received high AIAM scores. (AIAM was not verified with poor condition sites.) Spearman rank correlation tests comparing AIAM and the field-based California Rapid Assessment Method (CRAM) results revealed that some components of the two methods were highly correlated. The application of AIAM is illustrated with time-series restoration trajectories of three southern California stream restoration projects aged 15 to 21 years. The trajectories indicate that the projects improved in condition in years following their restoration, with vegetation showing the most dynamic change over time. AIAM restoration trajectories also overlapped to different degrees with CRAM chronosequence restoration performance curves that demonstrate the hypothetical development of high-performing projects. AIAM has high potential as a remote ecological assessment method and effective tool to determine restoration trajectories. Ultimately, this tool could be used to further improve stream and wetland restoration management.

  10. Validation of the Seattle angina questionnaire in women with ischemic heart disease.

    PubMed

    Patel, Krishna K; Arnold, Suzanne V; Chan, Paul S; Tang, Yuanyuan; Jones, Philip G; Guo, Jianping; Buchanan, Donna M; Qintar, Mohammed; Decker, Carole; Morrow, David A; Spertus, John A

    2018-07-01

    Although the Seattle Angina Questionnaire (SAQ) has been widely used to assess disease-specific health status in patients with ischemic heart disease, it was originally developed in a predominantly male population and its validity in women has been questioned. Using data from 8892 men and 4013 women across 2 multicenter trials and 5 registries, we assessed the construct validity, test-retest reliability, responsiveness to clinical change, and predictive validity of the SAQ Summary Score (SS) and its 5 subdomains (Physical Limitation (PL), Anginal Stability (AS), Angina Frequency (AF), Treatment Satisfaction (TS), and Quality of Life (QoL)) separately in men and women. Comparable correlations of the SAQ SS with Canadian Cardiovascular Society class was demonstrated in both men and women (-0.48 for men, -0.46 for women). Similar correlations between the SAQ PL scale with treadmill exercise duration and Short Form-12 (SF-12) Physical Component Summary were observed in women and men (0.34-0.63 and 0.40-0.63, respectively). SAQ AS scores were significantly lower for both men and women with acute syndromes compared with 1 month later. The SAQ AF scale was strongly correlated with daily angina diaries (0.62 for men and 0.66 for women). The SAQ QoL scores were moderately correlated with the EQ5D visual analog scale and SF-12 general health question in men (0.43-0.50) and women (0.33-0.39). All SAQ scales demonstrated excellent reliability (intraclass correlation ≥0.78) in both men and women with stable CAD and were very sensitive to change after percutaneous coronary intervention (≥15-point difference in scores, standardized response mean ≥ 0.67). The SAQ SS was similarly predictive of 1-year mortality and cardiac re-hospitalizations for both men and women. The SAQ demonstrates similar psychometric properties in men and women with CAD. These findings provide evidence for validity of the SAQ in assessing women with IHD. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. The development and reliability of a simple field based screening tool to assess core stability in athletes.

    PubMed

    O'Connor, S; McCaffrey, N; Whyte, E; Moran, K

    2016-07-01

    To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Highly effective electronic passivation of silicon surfaces by atomic layer deposited hafnium oxide

    NASA Astrophysics Data System (ADS)

    Cui, Jie; Wan, Yimao; Cui, Yanfeng; Chen, Yifeng; Verlinden, Pierre; Cuevas, Andres

    2017-01-01

    This paper investigates the application of hafnium oxide (HfO2) thin films to crystalline silicon (c-Si) solar cells. Excellent passivation of both n- and p-type crystalline silicon surfaces has been achieved by the application of thin HfO2 films prepared by atomic layer deposition. Effective surface recombination velocities as low as 3.3 and 9.9 cm s-1 have been recorded with 15 nm thick films on n- and p-type 1 Ω cm c-Si, respectively. The surface passivation by HfO2 is activated at 350 °C by a forming gas anneal. Capacitance voltage measurement shows an interface state density of 3.6 × 1010 cm-2 eV-1 and a positive charge density of 5 × 1011 cm-2 on annealed p-type 1 Ω cm c-Si. X-ray diffraction unveils a positive correlation between surface recombination and crystallinity of the HfO2 and a dependence of the crystallinity on both annealing temperature and film thickness. In summary, HfO2 is demonstrated to be an excellent candidate for surface passivation of crystalline silicon solar cells.

  13. Highly Efficient Small Form Factor LED Retrofit Lamp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steven Allen; Fred Palmer; Ming Li

    2011-09-11

    This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent powermore » quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.« less

  14. Recent advancements in robotic micro-optical assembly at the Lockheed Martin Optical Payload Center of Excellence

    NASA Astrophysics Data System (ADS)

    Hwang, David; Larson, Thomas M.

    2017-08-01

    Lockheed Martin Space Systems Company Optical Payloads Center of Excellence is in process of standing up the Robotic Optical Assembly System (ROAS) capability at Lockheed Martin Coherent Technologies in Colorado. This currently implemented Robotic Optical Assembly has enabled Lockheed Martin to create world-leading, ultra-lowSWAP photonic devices using a closed-loop control robot to precisely position and align micro-optics with a potential fill factor of >25 optics per square inch. This paper will discuss the anticipated applications and optical capability when ROAS is fully operational, as well as challenge the audience to update their "rules of thumb" and best practices when designing low-SWAP optical-mechanical systems that take advantage of Lockheed Martin's ROAS capability. This paper will reveal demonstrated optical pointing and stability performance achievable with ROAS and why we believe these optical specifications are relevant for the majority of anticipated applications. After a high level overview of the ROAS current state, this paper will focus in on recent results of the "Reworkable Micro-Optics Mounting IRAD". Results from this IRAD will correlate to the anticipated optical specifications required for relevant applications.

  15. Fold rise in antibody titers by measured by glycoprotein-based enzyme-linked immunosorbent assay is an excellent correlate of protection for a herpes zoster vaccine, demonstrated via the vaccine efficacy curve.

    PubMed

    Gilbert, Peter B; Gabriel, Erin E; Miao, Xiaopeng; Li, Xiaoming; Su, Shu-Chih; Parrino, Janie; Chan, Ivan S F

    2014-11-15

    The phase III Zostavax Efficacy and Safety Trial of 1 dose of licensed zoster vaccine (ZV; Zostavax; Merck) in 50-59-year-olds showed approximately 70% vaccine efficacy (VE) to reduce the incidence of herpes zoster (HZ). An objective of the trial was to assess immune response biomarkers measuring antibodies to varicella zoster virus (VZV) by glycoprotein-based enzyme-linked immunosorbent assay as correlates of protection (CoPs) against HZ. The principal stratification vaccine efficacy curve framework for statistically evaluating immune response biomarkers as CoPs was applied. The VE curve describes how VE against the clinical end point (HZ) varies across participant subgroups defined by biomarker readout measuring vaccine-induced immune response. The VE curve was estimated using several subgroup definitions. The fold rise in VZV antibody titers from the time before immunization to 6 weeks after immunization was an excellent CoP, with VE increasing sharply with fold rise: VE was estimated at 0% for the subgroup with no rise and at 90% for the subgroup with 5.26-fold rise. In contrast, VZV antibody titers measured 6 weeks after immunization did not predict VE, with similar estimated VEs across titer subgroups. The analysis illustrates the value of the VE curve framework for assessing immune response biomarkers as CoPs in vaccine efficacy trials. NCT00534248. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Comparing Two Processing Pipelines to Measure Subcortical and Cortical Volumes in Patients with and without Mild Traumatic Brain Injury.

    PubMed

    Reid, Matthew W; Hannemann, Nathan P; York, Gerald E; Ritter, John L; Kini, Jonathan A; Lewis, Jeffrey D; Sherman, Paul M; Velez, Carmen S; Drennon, Ann Marie; Bolzenius, Jacob D; Tate, David F

    2017-07-01

    To compare volumetric results from NeuroQuant® and FreeSurfer in a service member setting. Since the advent of medical imaging, quantification of brain anatomy has been a major research and clinical effort. Rapid advancement of methods to automate quantification and to deploy this information into clinical practice has surfaced in recent years. NeuroQuant® is one such tool that has recently been used in clinical settings. Accurate volumetric data are useful in many clinical indications; therefore, it is important to assess the intermethod reliability and concurrent validity of similar volume quantifying tools. Volumetric data from 148 U.S. service members across three different experimental groups participating in a study of mild traumatic brain injury (mTBI) were examined. Groups included mTBI (n = 71), posttraumatic stress disorder (n = 22), or a noncranial orthopedic injury (n = 55). Correlation coefficients and nonparametric group mean comparisons were used to assess reliability and concurrent validity, respectively. Comparison of these methods across our entire sample demonstrates generally fair to excellent reliability as evidenced by large intraclass correlation coefficients (ICC = .4 to .99), but little concurrent validity as evidenced by significantly different Mann-Whitney U comparisons for 26 of 30 brain structures measured. While reliability between the two segmenting tools is fair to excellent, volumetric outcomes are statistically different between the two methods. As suggested by both developers, structure segmentation should be visually verified prior to clinical use and rigor should be used when interpreting results generated by either method. Copyright © 2017 by the American Society of Neuroimaging.

  17. The Salivary β-HEX A% Index as an Excellent Marker of Periodontitis in Smoking Alcohol-Dependent Persons

    PubMed Central

    Waszkiewicz, Napoleon; Zalewska-Szajda, Beata; Chojnowska, Sylwia; Szajda, Sławomir Dariusz; Zalewska, Anna; Konarzewska, Beata; Szulc, Agata; Wojtulewska-Supron, Aleksandra; Kępka, Alina; Knaś, Małgorzata; Ładny, Jerzy Robert; Milewski, Robert; Zwierz, Krzysztof

    2013-01-01

    Background. Severe periodontitis leading to tooth loss is found in 5–15% of most populations worldwide. Aim. The applicability of salivary β-hexosaminidase (β-HEX A%, percentage of β-HEX A isoenzyme to total β-HEX) and β-HEX B% (β-HEX B/β-HEX) indexes was investigated as a possible marker of periodontitis. Methods. Thirty three alcohol-dependent smokers (AS) and 32 healthy controls (C) were enrolled in the study. The activity of β-HEX was measured spectrophotometrically. Results. β-HEX A% was significantly higher and β-HEX B% was lower in AS than in C group. We found a significant correlation between β-HEX A% and gingival index (GI) and an inverse correlation between β-HEX A% and salivary flow (SF), in all groups. Salivary β-HEX A% index in smoking alcoholics at 0.23 had excellent sensitivity (96%) and specificity (91%); the AUC for β-HEX A% was high (0.937). There were no correlations between amount/duration-time of alcohol drinking/smoking and β-HEX A% or β-HEX B%. We found significant correlations between the time period of denture wearing and GI, papilla bleeding index (PBI), and decayed missing filled teeth index (DMFT) and between GI and the amount of smoked cigarettes per day. Conclusion. Bad periodontal state was most likely due to the nicotine dependence. Salivary β-HEX A% is a promising excellent marker for the diagnosis of periodontitis. PMID:24288426

  18. Morphological Control of Au Dendrite Electrocatalysts for CO2 Reduction

    NASA Astrophysics Data System (ADS)

    Nesbitt, Nathan T.; Ma, Ming; Carter, Brittany E.; D'Imperio, Luke A.; Naughton, Jeffrey R.; Courtney, Dave T.; Shepard, Steve; Burns, Michael J.; Smith, Wilson A.; Naughton, Michael J.

    Au has demonstrated the highest catalytic selectivity, activity, and stability for CO2 reduction to CO of any metal, but the mechanism for this performance remains unclear. Studies of nanoparticle films have shown that higher index facets have improved performance, but the preeminent nanoparticle films, from oxide-derived Au, lack well-defined facets and morphological stability to illuminate their enabling mechanism. More recent work has shown Au needles with a sub 5 nm radius of curvature have excellent performance and stability, independent of crystal facet. The same studies, however, still show calculations expecting a facet dependance. Here we demonstrate a facile and novel dendrite fabrication process with tunable morphology. The dendrites show high catalytic selectivity, activity, and stability for CO2 reduction to CO, along with morphological stability after 18 hours of operation, allowing correlation between morphology and performance. The influence of exposed facets will be discussed. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship under Grant No. (DGE-1258923).

  19. Computation of load performance and other parameters of extra high speed modified Lundell alternators from 3D-FE magnetic field solutions

    NASA Technical Reports Server (NTRS)

    Wang, R.; Demerdash, N. A.

    1992-01-01

    The combined magnetic vector potential - magnetic scalar potential method of computation of 3D magnetic fields by finite elements, introduced in a companion paper, in combination with state modeling in the abc-frame of reference, are used for global 3D magnetic field analysis and machine performance computation under rated load and overload condition in an example 14.3 kVA modified Lundell alternator. The results vividly demonstrate the 3D nature of the magnetic field in such machines, and show how this model can be used as an excellent tool for computation of flux density distributions, armature current and voltage waveform profiles and harmonic contents, as well as computation of torque profiles and ripples. Use of the model in gaining insight into locations of regions in the magnetic circuit with heavy degrees of saturation is demonstrated. Experimental results which correlate well with the simulations of the load case are given.

  20. Correlation of energy disorder and open-circuit voltage in hybrid perovskite solar cells

    DOE PAGES

    Shao, Yuchuan; Yuan, Yongbo; Huang, Jinsong

    2016-01-11

    Organometal trihalide perovskites have been demonstrated as excellent light absorbers for high efficiency photovoltaic applications. Previous approaches to increasing the solar cell efficiency have focussed on optimisation of the grain morphology of perovskite thin films. Here, we show that the structural order of the electron-transport layers also has a significant impact on solar cell performance. We demonstrate that the power conversion efficiency of CH 3NH 3PbI 3 planar-heterojunction photovoltaic cells increases from 17.1% to 19.4% when the energy disorder in the fullerene electron-transport layer is reduced by a simple solvent annealing process. The increase in efficiency is the result ofmore » the enhancement in open-circuit voltage from 1.04 V to 1.13 V without sacrificing the short-circuit current and fill factor. Finally, these results shed light on the origin of open-circuit voltage in perovskite solar cells, and provide a new path to further increase their efficiency« less

  1. 500  Gb/s free-space optical transmission over strong atmospheric turbulence channels.

    PubMed

    Qu, Zhen; Djordjevic, Ivan B

    2016-07-15

    We experimentally demonstrate a high-spectral-efficiency, large-capacity, featured free-space-optical (FSO) transmission system by using low-density, parity-check (LDPC) coded quadrature phase shift keying (QPSK) combined with orbital angular momentum (OAM) multiplexing. The strong atmospheric turbulence channel is emulated by two spatial light modulators on which four randomly generated azimuthal phase patterns yielding the Andrews spectrum are recorded. The validity of such an approach is verified by reproducing the intensity distribution and irradiance correlation function (ICF) from the full-scale simulator. Excellent agreement of experimental, numerical, and analytical results is found. To reduce the phase distortion induced by the turbulence emulator, the inexpensive wavefront sensorless adaptive optics (AO) is used. To deal with remaining channel impairments, a large-girth LDPC code is used. To further improve the aggregate data rate, the OAM multiplexing is combined with WDM, and 500 Gb/s optical transmission over the strong atmospheric turbulence channels is demonstrated.

  2. Measuring Nutrition Literacy in Spanish-Speaking Latinos: An Exploratory Validation Study.

    PubMed

    Gibbs, Heather D; Camargo, Juliana M T B; Owens, Sarah; Gajewski, Byron; Cupertino, Ana Paula

    2017-11-21

    Nutrition is important for preventing and treating chronic diseases highly prevalent among Latinos, yet no tool exists for measuring nutrition literacy among Spanish speakers. This study aimed to adapt the validated Nutrition Literacy Assessment Instrument for Spanish-speaking Latinos. This study was developed in two phases: adaptation and validity testing. Adaptation included translation, expert item content review, and interviews with Spanish speakers. For validity testing, 51 participants completed the Short Assessment of Health Literacy-Spanish (SAHL-S), the Nutrition Literacy Assessment Instrument in Spanish (NLit-S), and socio-demographic questionnaire. Validity and reliability statistics were analyzed. Content validity was confirmed with a Scale Content Validity Index of 0.96. Validity testing demonstrated NLit-S scores were strongly correlated with SAHL-S scores (r = 0.52, p < 0.001). Entire reliability was substantial at 0.994 (CI 0.992-0.996) and internal consistency was excellent (Cronbach's α = 0.92). The NLit-S demonstrates validity and reliability for measuring nutrition literacy among Spanish-speakers.

  3. Predictors of future success in otolaryngology residency applicants.

    PubMed

    Chole, Richard A; Ogden, M Allison

    2012-08-01

    To evaluate the information available about otolaryngology residency applicants for factors that may predict future success as an otolaryngologist. Retrospective review of residency applications; survey of resident graduates and otolaryngology clinical faculty. Otolaryngology residency program. Otolaryngology program graduates from 2001 to 2010 and current clinical faculty from Barnes-Jewish Hospital/Washington University School of Medicine. Overall ratings of the otolaryngology graduates by clinical faculty (on a 5-point scale) were compared with the resident application attributes that might predict success. The application factors studied are United States Medical Licensing Examination part 1 score, Alpha Omega Alpha Honor Medical Society election, medical school grades, letter of recommendation, rank of the medical school, extracurricular activities, residency interview, experience with acting intern, and extracurricular activities. Forty-six graduates were included in the study. The overall faculty rating of the residents showed good interrater reliability. The objective factors, letters of recommendation, experience as an acting intern, and musical excellence showed no correlation with higher faculty rating. Rank of the medical school and faculty interview weakly correlated with faculty rating. Having excelled in a team sport correlated with higher faculty rating. Many of the application factors typically used during otolaryngology residency candidate selection may not be predictive of future capabilities as a clinician. Prior excellence in a team sport may suggest continued success in the health care team.

  4. Right adolescent idiopathic thoracic curve (Lenke 1 A and B): does cost of instrumentation and implant density improve radiographic and cosmetic parameters?

    PubMed

    Yang, Scott; Jones-Quaidoo, Sean M; Eager, Matthew; Griffin, Justin W; Reddi, Vasantha; Novicoff, Wendy; Shilt, Jeffrey; Bersusky, Ernesto; Defino, Helton; Ouellet, Jean; Arlet, Vincent

    2011-07-01

    In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman's correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54° (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.

  5. A Microsoft-Excel-based tool for running and critically appraising network meta-analyses--an overview and application of NetMetaXL.

    PubMed

    Brown, Stephen; Hutton, Brian; Clifford, Tammy; Coyle, Doug; Grima, Daniel; Wells, George; Cameron, Chris

    2014-09-29

    The use of network meta-analysis has increased dramatically in recent years. WinBUGS, a freely available Bayesian software package, has been the most widely used software package to conduct network meta-analyses. However, the learning curve for WinBUGS can be daunting, especially for new users. Furthermore, critical appraisal of network meta-analyses conducted in WinBUGS can be challenging given its limited data manipulation capabilities and the fact that generation of graphical output from network meta-analyses often relies on different software packages than the analyses themselves. We developed a freely available Microsoft-Excel-based tool called NetMetaXL, programmed in Visual Basic for Applications, which provides an interface for conducting a Bayesian network meta-analysis using WinBUGS from within Microsoft Excel. . This tool allows the user to easily prepare and enter data, set model assumptions, and run the network meta-analysis, with results being automatically displayed in an Excel spreadsheet. It also contains macros that use NetMetaXL's interface to generate evidence network diagrams, forest plots, league tables of pairwise comparisons, probability plots (rankograms), and inconsistency plots within Microsoft Excel. All figures generated are publication quality, thereby increasing the efficiency of knowledge transfer and manuscript preparation. We demonstrate the application of NetMetaXL using data from a network meta-analysis published previously which compares combined resynchronization and implantable defibrillator therapy in left ventricular dysfunction. We replicate results from the previous publication while demonstrating result summaries generated by the software. Use of the freely available NetMetaXL successfully demonstrated its ability to make running network meta-analyses more accessible to novice WinBUGS users by allowing analyses to be conducted entirely within Microsoft Excel. NetMetaXL also allows for more efficient and transparent critical appraisal of network meta-analyses, enhanced standardization of reporting, and integration with health economic evaluations which are frequently Excel-based.

  6. A Microsoft-Excel-based tool for running and critically appraising network meta-analyses—an overview and application of NetMetaXL

    PubMed Central

    2014-01-01

    Background The use of network meta-analysis has increased dramatically in recent years. WinBUGS, a freely available Bayesian software package, has been the most widely used software package to conduct network meta-analyses. However, the learning curve for WinBUGS can be daunting, especially for new users. Furthermore, critical appraisal of network meta-analyses conducted in WinBUGS can be challenging given its limited data manipulation capabilities and the fact that generation of graphical output from network meta-analyses often relies on different software packages than the analyses themselves. Methods We developed a freely available Microsoft-Excel-based tool called NetMetaXL, programmed in Visual Basic for Applications, which provides an interface for conducting a Bayesian network meta-analysis using WinBUGS from within Microsoft Excel. . This tool allows the user to easily prepare and enter data, set model assumptions, and run the network meta-analysis, with results being automatically displayed in an Excel spreadsheet. It also contains macros that use NetMetaXL’s interface to generate evidence network diagrams, forest plots, league tables of pairwise comparisons, probability plots (rankograms), and inconsistency plots within Microsoft Excel. All figures generated are publication quality, thereby increasing the efficiency of knowledge transfer and manuscript preparation. Results We demonstrate the application of NetMetaXL using data from a network meta-analysis published previously which compares combined resynchronization and implantable defibrillator therapy in left ventricular dysfunction. We replicate results from the previous publication while demonstrating result summaries generated by the software. Conclusions Use of the freely available NetMetaXL successfully demonstrated its ability to make running network meta-analyses more accessible to novice WinBUGS users by allowing analyses to be conducted entirely within Microsoft Excel. NetMetaXL also allows for more efficient and transparent critical appraisal of network meta-analyses, enhanced standardization of reporting, and integration with health economic evaluations which are frequently Excel-based. PMID:25267416

  7. Reliability and Validity of Dual-Task Mobility Assessments in People with Chronic Stroke

    PubMed Central

    Yang, Lei; He, Chengqi; Pang, Marco Yiu Chung

    2016-01-01

    Background The ability to perform a cognitive task while walking simultaneously (dual-tasking) is important in real life. However, the psychometric properties of dual-task walking tests have not been well established in stroke. Objective To assess the test-retest reliability, concurrent and known-groups validity of various dual-task walking tests in people with chronic stroke. Design Observational measurement study with a test-retest design. Methods Eighty-eight individuals with chronic stroke participated. The testing protocol involved four walking tasks (walking forward at self-selected and maximal speed, walking backward at self-selected speed, and crossing over obstacles) performed simultaneously with each of the three attention-demanding tasks (verbal fluency, serial 3 subtractions or carrying a cup of water). For each dual-task condition, the time taken to complete the walking task, the correct response rate (CRR) of the cognitive task, and the dual-task effect (DTE) for the walking time and CRR were calculated. Forty-six of the participants were tested twice within 3–4 days to establish test-retest reliability. Results The walking time in various dual-task assessments demonstrated good to excellent reliability [Intraclass correlation coefficient (ICC2,1) = 0.70–0.93; relative minimal detectable change at 95% confidence level (MDC95%) = 29%-45%]. The reliability of the CRR (ICC2,1 = 0.58–0.81) and the DTE in walking time (ICC2,1 = 0.11–0.80) was more varied. The reliability of the DTE in CRR (ICC2,1 = -0.31–0.40) was poor to fair. The walking time and CRR obtained in various dual-task walking tests were moderately to strongly correlated with those of the dual-task Timed-up-and-Go test, thus demonstrating good concurrent validity. None of the tests could discriminate fallers (those who had sustained at least one fall in the past year) from non-fallers. Limitation The results are generalizable to community-dwelling individuals with chronic stroke only. Conclusions The walking time derived from the various dual-task assessments generally demonstrated good to excellent reliability, making them potentially useful in clinical practice and future research endeavors. However, the usefulness of these measurements in predicting falls needs to be further explored. Relatively low reliability was shown in the cognitive outcomes and DTE, which may not be preferred measurements for assessing dual-task performance. PMID:26808662

  8. The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

    PubMed

    Padayachy, Llewellyn C; Padayachy, Vaishali; Galal, Ushma; Gray, Rebecca; Fieggen, A Graham

    2016-10-01

    The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and  repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97-0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.

  9. Comparing Exponential and Exponentiated Models of Drug Demand in Cocaine Users

    PubMed Central

    Strickland, Justin C.; Lile, Joshua A.; Rush, Craig R.; Stoops, William W.

    2016-01-01

    Drug purchase tasks provide rapid and efficient measurement of drug demand. Zero values (i.e., prices with zero consumption) present a quantitative challenge when using exponential demand models that exponentiated models may resolve. We aimed to replicate and advance the utility of using an exponentiated model by demonstrating construct validity (i.e., association with real-world drug use) and generalizability across drug commodities. Participants (N = 40 cocaine-using adults) completed Cocaine, Alcohol, and Cigarette Purchase Tasks evaluating hypothetical consumption across changes in price. Exponentiated and exponential models were fit to these data using different treatments of zero consumption values, including retaining zeros or replacing them with 0.1, 0.01, 0.001. Excellent model fits were observed with the exponentiated model. Means and precision fluctuated with different replacement values when using the exponential model, but were consistent for the exponentiated model. The exponentiated model provided the strongest correlation between derived demand intensity (Q0) and self-reported free consumption in all instances (Cocaine r = .88; Alcohol r = .97; Cigarette r = .91). Cocaine demand elasticity was positively correlated with alcohol and cigarette elasticity. Exponentiated parameters were associated with real-world drug use (e.g., weekly cocaine use), whereas these correlations were less consistent for exponential parameters. Our findings show that selection of zero replacement values impact demand parameters and their association with drug-use outcomes when using the exponential model, but not the exponentiated model. This work supports the adoption of the exponentiated demand model by replicating improved fit and consistency, in addition to demonstrating construct validity and generalizability. PMID:27929347

  10. Comparing exponential and exponentiated models of drug demand in cocaine users.

    PubMed

    Strickland, Justin C; Lile, Joshua A; Rush, Craig R; Stoops, William W

    2016-12-01

    Drug purchase tasks provide rapid and efficient measurement of drug demand. Zero values (i.e., prices with zero consumption) present a quantitative challenge when using exponential demand models that exponentiated models may resolve. We aimed to replicate and advance the utility of using an exponentiated model by demonstrating construct validity (i.e., association with real-world drug use) and generalizability across drug commodities. Participants (N = 40 cocaine-using adults) completed Cocaine, Alcohol, and Cigarette Purchase Tasks evaluating hypothetical consumption across changes in price. Exponentiated and exponential models were fit to these data using different treatments of zero consumption values, including retaining zeros or replacing them with 0.1, 0.01, or 0.001. Excellent model fits were observed with the exponentiated model. Means and precision fluctuated with different replacement values when using the exponential model but were consistent for the exponentiated model. The exponentiated model provided the strongest correlation between derived demand intensity (Q0) and self-reported free consumption in all instances (Cocaine r = .88; Alcohol r = .97; Cigarette r = .91). Cocaine demand elasticity was positively correlated with alcohol and cigarette elasticity. Exponentiated parameters were associated with real-world drug use (e.g., weekly cocaine use) whereas these correlations were less consistent for exponential parameters. Our findings show that selection of zero replacement values affects demand parameters and their association with drug-use outcomes when using the exponential model but not the exponentiated model. This work supports the adoption of the exponentiated demand model by replicating improved fit and consistency and demonstrating construct validity and generalizability. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  11. Arkansas State & UNVL Earn the 2010 Award for Excellence

    ERIC Educational Resources Information Center

    Facilities Manager, 2010

    2010-01-01

    APPA's highest institutional honor, the Award for Excellence in Facilities Management (AFE), recognizes those educational institutions whose facilities management organizations demonstrate quality in overall operations and effectiveness. The two most recent recipients, Arkansas State University-Jonesboro (ASU-J) and the University of Nevada-Las…

  12. Validity of Exercise Measures in Adults with Anorexia Nervosa: The EDE, Compulsive Exercise Test and Other Self-Report Scales.

    PubMed

    Young, Sarah; Touyz, Stephen; Meyer, Caroline; Arcelus, Jon; Rhodes, Paul; Madden, Sloane; Pike, Kathleen; Attia, Evelyn; Crosby, Ross D; Wales, Jackie; Hay, Phillipa

    2017-05-01

    Compulsive exercise is a prominent feature for the majority of patients with Anorexia Nervosa (AN), but there is a dearth of research evaluating assessment instruments. This study assessed the concurrent validity of the exercise items of the Eating Disorder Examination (EDE) and Eating Disorder Examination-Questionnaire (EDE-Q), with the Compulsive Exercise Test (CET) and other self-report exercise measures in patients with AN. We also aimed to perform validation of the CET in an adult clinical sample. The sample consisted of 78 adults with AN, recruited for the randomized controlled trial "Taking a LEAP forward in the treatment of anorexia nervosa." At baseline, participants completed the EDE, EDE-Q, CET, Reasons for Exercise Inventory (REI), Commitment to Exercise Scale (CES) and Exercise Beliefs Questionnaire (EBQ). Correlational and regression analyses were performed. EDE exercise days and exercise time per day were positively correlated with each other and with all CET subscales (except Lack of exercise enjoyment), CES mean, EBQ total and REI total. Exercise time per day was associated with a higher EDE global score. The CET demonstrated good concurrent validity with the CES, the REI and the EBQ. Of the self-reports, the CET explained the greatest variance in eating disorder psychopathology and demonstrated good to excellent reliability in this sample. The EDE and EDE-Q demonstrated good concurrent validity with the CET. Further research is required to evaluate the CET's factor structure in a large clinical sample. However, the CET has demonstrated strong clinical utility in adult patients with AN. © 2016 Wiley Periodicals, Inc.(Int J Eat Disord 2017; 50:533-541). © 2016 Wiley Periodicals, Inc.

  13. Excel VBA for Physicists; A Primer

    NASA Astrophysics Data System (ADS)

    Liengme, Bernard V.

    2016-11-01

    This book is both an introduction and a demonstration of how Visual Basic for Applications (VBA) can greatly enhance Microsoft Excel® by giving users the ability to create their own functions within a worksheet and to create subroutines to perform repetitive actions. The book is written so readers are encouraged to experiment with VBA programming with examples using fairly simple physics or non-complicated mathematics such as root finding and numerical integration. Tested Excel® workbooks are available for each chapter and there is nothing to buy or install. A tested Excel workbook for each chapter can be downloaded from Book information

  14. Solar energy potential in the United Arab Emirates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khalil, A.; Alnajjar, A.

    1995-12-31

    In the present study, the global, direct and diffuse components of solar radiation as well as temperature, relative humidity and wind speed have been continuously monitored and analyzed on hourly, daily and monthly basis. Experimental data is compared to the predictions of different theoretical models as functions of declination and hour angles. Correlations are obtained describing the variation of hourly, daily and monthly averages of total and diffuse solar radiation using polynomial expressions. Empirical correlations describing the dependence of the daily average diffuse to total radiation ratio on the clearness index are also obtained. Data of daily diffuse to totalmore » radiation ratio is compared to correlations obtained by other investigators. The comparison shows a reasonable agreement with some scatter due to the seasonal dependence of the correlation. Comparison of calculations with experimental measurements under clear sky conditions show excellent agreement with a maximum error of 8%. The measured ratio of hourly to daily insolation is in excellent agreement with the model of Hottel which is expressed as a function of the clearness index, hour and the sunset hour angles.« less

  15. The factor structure and construct validity of the inventory of callous-unemotional traits in Chinese undergraduate students.

    PubMed

    Wang, Meng-Cheng; Gao, Yu; Deng, Jiaxin; Lai, Hongyu; Deng, Qiaowen; Armour, Cherie

    2017-01-01

    The current study assesses the factor structure and construct validity of the self-reported Inventory of Callous-Unemotional Traits (ICU) in 637 Chinese community adults (mean age = 25.98, SD = 5.79). A series of theoretical models proposed in previous studies were tested through confirmatory factor analyses. Results indicated that a shortened form that consists of 11 items (ICU-11) to assess callousness and uncaring factors has excellent overall fit. Additionally, correlations with a wide range of external variables demonstrated that this shortened form has similar construct validity compared to the original ICU. In conclusion, our findings suggest that the ICU-11 may be a promising self-report tool that could be a good substitute for the original form to assess callous-uncaring traits in adults.

  16. OAO-3 end of mission power subsystem evaluation

    NASA Technical Reports Server (NTRS)

    Tasevoli, M.

    1982-01-01

    End of mission tests were performed on the OAO-3 power subsystem in three component areas: solar array, nickel-cadmium batteries and the On-Board Processor (OBP) power boost operation. Solar array evaluation consisted of analyzing array performance characteristics and comparing them to earlier flight data. Measured solar array degradation of 14.1 to 17.7% after 8 1/3 years is in good agreement with theortical radiation damage losses. Battery discharge characteristics were compared to results of laboratory life cycle tests performed on similar cells. Comparison of cell voltage profils reveals close correlation and confirms the validity of real time life cycle simulation. The successful operation of the system in the OBP/power boost regulation mode demonstrates the excellent life, reliability and greater system utilization of power subsystems using maximum power trackers.

  17. A Comparison of Organizational Climate and Nurses’ Intention to Leave Among Excellence Awarded Hospitals and Other Hospitals in 2013

    PubMed Central

    Mohamadzadeh Nojehdehi, Maryam; Ashgholi Farahani, Mansoureh; Rafii, Forough; Bahrani, Nasser

    2015-01-01

    Background: Human resource is the most important factor of performance, success and better revelation of excellence goals of each organization. By performing excellence plan, healthcare organizations improve their organizational climate and play a valuable role in retaining nurses and improving the quality of their services to patients. Objectives: The aim of this study was to compare hospital organizational climate and intention to leave among working nurses in hospitals performing the excellence plan and other hospitals of Tehran University of Medical Sciences. Patients and Methods: This was a cross-sectional descriptive comparison study. Its population included 248 nurses of the hospitals performing the excellence plan and other hospitals of Tehran University of Medical Sciences in Iran selected by random sampling. The used instrument had three parts: the first part was related to personal characteristics, the second part was the Munn’s organizational climate questionnaire and the third part was Hinshaw’s questionnaire of “anticipated turnover scale”. Data was analyzed using SPSS software, version 17 and indices of descriptive statistics and inferential statistics. Results: The results of the mean and standard deviation for organizational climate and intention to leave in both performing and non-performing hospitals of the organizational excellence plan were respectively (65.28 ± 19.31 and 56.42 ± 21.36) and (33.64 ± 5.58 and 35.59 ± 4.94). Independent T test revealed a significant difference between the mean scores for organizational climate in both performing and non-performing hospitals, and also a significant difference between the mean scores for intention to leave in both performing and non-performing hospitals (P = 0.004). Moreover, Pearson Correlation test showed a reverse significant correlation between organizational climate and intention to leave in performing hospitals of the organizational excellence plan (r = -0.337) and non-performing hospitals (r = -0.282) (P = 0.001). Conclusions: Performing quality improvement pattern such as organization’s excellence plan improves organizational climate of healthcare sectors, it can reduce nurses’ intentions to leave and retain human resources. PMID:26082850

  18. The Elitism Dispositif: Hierarchization, Discourses of Excellence and Organizational Change in European Economics

    ERIC Educational Resources Information Center

    Maesse, Jens

    2017-01-01

    From the 1990s onwards, economics departments in Europe have changed toward a culture of "excellence." Strong academic hierarchies and new forms of academic organization replace "institutes" and "colleges" by fully equipped "economics departments." This article seeks to demonstrate how and why…

  19. HACC, Pima CC, and CU-Boulder Win the 2012 Award for Excellence

    ERIC Educational Resources Information Center

    Wojtysiak, Joseph R.; Ward, William R., II; Potter, Lisa

    2012-01-01

    APPA's highest institutional honor, the Award for Excellence in Facilities Management (AFE), recognizes those educational institutions whose facilities management organizations demonstrate quality in overall operations and effectiveness. This article presents the three most recent recipients--Harrisburg Area Community College in Pennsylvania, Pima…

  20. Remote assessment of stroke using the iPhone 4.

    PubMed

    Anderson, Eric R; Smith, Bryan; Ido, Moges; Frankel, Michael

    2013-05-01

    Therapy with recombinant tissue plasminogen activator is underused in the treatment of ischemic stroke in rural hospitals, due to a lack of local stroke expertise. Telemedicine solutions for stroke are a level I, class A recommendation when a vascular neurologist is absent. However, current solutions require exorbitant startup costs, which are prohibitive for the rural hospitals in which they are needed most. This study demonstrates the efficacy of using the relatively inexpensive iPhone 4 in telestroke management. Twenty patients with stroke were assessed at the bedside using an iPhone 4, and each examination was directed remotely on another iPhone 4. Both the physician performing the bedside exam and the remote physician calculated a National Institutes of Health Stroke Scale (NIHSS) score for each patient. Each physician was blinded to the other's NIHSS score. In the 20 patients assessed, NIHSS scores ranged from 0 to 22. Interrater reliability assessed using the κ statistic demonstrated excellent agreement in 10 items (level of consciousness, month and age, visual fields, right motor arm, left motor arm, right motor leg, left motor leg, sensation, language, and neglect), moderate agreement in 3 items (gaze, facial palsy, and dysarthria), and poor agreement in 1 item (ataxia). Total NIHSS scores obtained remotely and at bedside showed an excellent level of agreement (intraclass correlation coefficient, 0.98). Our findings indicate that the iPhone 4 is an economical mobile solution that can be used to assess stroke patients remotely with high fidelity and can be readily incorporated into a telestroke network. Copyright © 2013 National Stroke Association. All rights reserved.

  1. Photosynthesis of alfalfa (Medicago sativa) in response to landfill leachate contamination.

    PubMed

    Yang, Lie; Sun, Tiantian; Liu, Yanli; Guo, Houqing; Lv, Lixin; Zhang, Jie; Liu, Chang

    2017-11-01

    Thousands of unlined landfills and open dumpsites have put great threat on the security of soil and ground water due to leachate leakage. Alfalfa is believed potential as a phytoremediation plant for leachate contamination based on strong root system and the excellent capacity of removing various kinds of pollutants. A lab-scale investigation was conducted to figure out the sensitiveness of alfalfa photosynthesis in response to leachate contamination. The results demonstrated that both of the maximum photosynthetic efficiency (F v /F m ) and net photosynthetic rate (P n ) were slightly inhibited in the high-dosage group. Based on statistical analysis, higher sensitivity of P n to leaching parameters than F v /F m was observed. There were significant correlations between most of leaching parameters (pH, ammonium and COD) and P n with correlation coefficients of 0.530, -0.580 and -0.578 (p < 0.01), respectively. Therefore, P n is potential for acting as an effective indicator for staple leaching characteristics of leachate contaminated soils. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Diesel Engine Valve Clearance Fault Diagnosis Based on Features Extraction Techniques and FastICA-SVM

    NASA Astrophysics Data System (ADS)

    Jing, Ya-Bing; Liu, Chang-Wen; Bi, Feng-Rong; Bi, Xiao-Yang; Wang, Xia; Shao, Kang

    2017-07-01

    Numerous vibration-based techniques are rarely used in diesel engines fault diagnosis in a direct way, due to the surface vibration signals of diesel engines with the complex non-stationary and nonlinear time-varying features. To investigate the fault diagnosis of diesel engines, fractal correlation dimension, wavelet energy and entropy as features reflecting the diesel engine fault fractal and energy characteristics are extracted from the decomposed signals through analyzing vibration acceleration signals derived from the cylinder head in seven different states of valve train. An intelligent fault detector FastICA-SVM is applied for diesel engine fault diagnosis and classification. The results demonstrate that FastICA-SVM achieves higher classification accuracy and makes better generalization performance in small samples recognition. Besides, the fractal correlation dimension and wavelet energy and entropy as the special features of diesel engine vibration signal are considered as input vectors of classifier FastICA-SVM and could produce the excellent classification results. The proposed methodology improves the accuracy of feature extraction and the fault diagnosis of diesel engines.

  3. Is synaptic loss a unique hallmark of Alzheimer's disease?

    PubMed Central

    Scheff, Stephen W.; Neltner, Janna H.; Nelson, Peter T.

    2014-01-01

    Synapses may represent a key nidus for dementia including Alzheimer's disease (AD) pathogenesis. Here we review published studies and present new ideas related to the question of the specificity of synapse loss in AD. Currently, AD is defined by the regional presence of neuritic plaques and neurofibrillary tangles in the brain. The severity of involvement by those pathological hallmarks tends to correlate both with antemortem cognitive status, and also with synapse loss in multiple brain areas. Recent studies from large autopsy series have led to a new standard of excellence with regard to clinical–pathological correlation and to improved comprehension of the numerous brain diseases of the elderly. These studies have provided evidence that it is the rule rather than the exception for brains of aged individuals to demonstrate pathologies (often multiple) other than AD plaques and tangles. For many of these comorbid pathologies, the extent of synapse loss is imperfectly understood but could be substantial. These findings indicate that synapse loss is probably not a hallmark specific to AD but rather a change common to many diseases associated with dementia. PMID:24412275

  4. Effects of fragility and reduced glass transition temperature on the glass formation ability of amorphous alloys

    NASA Astrophysics Data System (ADS)

    Xu, Xiao-Jin; Long, Zhi-Lin; Liu, Wei; Liao, Guang-Kai

    2017-11-01

    In this paper, based on the reduced glass transition temperature ({{T}rg} ) proposed by Turnbull and the relation between the glass-forming ability (GFA) and the short-range bond ordering of liquids demonstrated by Tanaka, a detailed analysis on the specific roles of {{T}rg} and fragility of the glass forming liquid (m) in characterizing the GFA has been conducted, and then a novel GFA parameter α [=2/3× (100{{T}rg}{)}-(16/100)× m=67{{T}rg}-0.16m] was put forward. This new GFA parameter α , which increases with a decrease in the critical cooling rate (R c) for glass formation, is a complex function of {{T}rg} and m. The relationship between R c and the parameter α was identified and verified using available literature data for broad range of amorphous alloys with widely varying GFA. The correlation coefficient (R 2) of 0.9 clearly shows an excellent correlation between GFA and the parameter α and that α is a more superior indicator compared to currently reported similar GFA parameters.

  5. Selective One-Dimensional Total Correlation Spectroscopy Nuclear Magnetic Resonance Experiments for a Rapid Identification of Minor Components in the Lipid Fraction of Milk and Dairy Products: Toward Spin Chromatography?

    PubMed

    Papaemmanouil, Christina; Tsiafoulis, Constantinos G; Alivertis, Dimitrios; Tzamaloukas, Ouranios; Miltiadou, Despoina; Tzakos, Andreas G; Gerothanassis, Ioannis P

    2015-06-10

    We report a rapid, direct, and unequivocal spin-chromatographic separation and identification of minor components in the lipid fraction of milk and common dairy products with the use of selective one-dimensional (1D) total correlation spectroscopy (TOCSY) nuclear magnetic resonance (NMR) experiments. The method allows for the complete backbone spin-coupling network to be elucidated even in strongly overlapped regions and in the presence of major components from 4 × 10(2) to 3 × 10(3) stronger NMR signal intensities. The proposed spin-chromatography method does not require any derivatization steps for the lipid fraction, is selective with excellent resolution, is sensitive with quantitation capability, and compares favorably to two-dimensional (2D) TOCSY and gas chromatography-mass spectrometry (GC-MS) methods of analysis. The results of the present study demonstrated that the 1D TOCSY NMR spin-chromatography method can become a procedure of primary interest in food analysis and generally in complex mixture analysis.

  6. Probing condensed matter physics with magnetometry based on nitrogen-vacancy centres in diamond

    NASA Astrophysics Data System (ADS)

    Casola, Francesco; van der Sar, Toeno; Yacoby, Amir

    2018-01-01

    The magnetic fields generated by spins and currents provide a unique window into the physics of correlated-electron materials and devices. First proposed only a decade ago, magnetometry based on the electron spin of nitrogen-vacancy (NV) defects in diamond is emerging as a platform that is excellently suited for probing condensed matter systems; it can be operated from cryogenic temperatures to above room temperature, has a dynamic range spanning from direct current to gigahertz and allows sensor-sample distances as small as a few nanometres. As such, NV magnetometry provides access to static and dynamic magnetic and electronic phenomena with nanoscale spatial resolution. Pioneering work has focused on proof-of-principle demonstrations of its nanoscale imaging resolution and magnetic field sensitivity. Now, experiments are starting to probe the correlated-electron physics of magnets and superconductors and to explore the current distributions in low-dimensional materials. In this Review, we discuss the application of NV magnetometry to the exploration of condensed matter physics, focusing on its use to study static and dynamic magnetic textures and static and dynamic current distributions.

  7. MAGSAT anomaly field inversion and interpretation for the US

    NASA Technical Reports Server (NTRS)

    Mayhew, M. A. (Principal Investigator)

    1982-01-01

    Long wavelength anomalies in the total magnetic field measured by MAGSAT over the United States and adjacent areas are inverted to an equivalent layer crustal magnetization distribution. The model is based on an equal area dipole grid at the Earth's surface. Model resolution, defined as the closest dipole spacing giving a solution having physical significance, is about 220 km for MAGSAT data in the elevation range 300-500 km. The magnetization contours correlate well with large scale tectonic provinces. A higher resolution (200 km) model based on relatively noise free synthetic "pseudodata" is also presented. Magnetic anomaly component data measured by MAGSAT is compared with synthetic anomaly component fields arising from an equivalent source dipole array at the Earth's surface generated from total field anomaly data alone. An excellent inverse correlation between apparent magnetization and heat flow in the western U.S. is demonstrated. A regional heat flow map which is presented and compared with published maps, predicts high heat flow in Nebraska and the Dakotas, suggesting the presence of a "blind" geothermal area of regional extent.

  8. Demonstration of the Kibble-Zurek mechanism in a non-equilibrium phase transition

    NASA Astrophysics Data System (ADS)

    Patil, Yogesh S.; Cheung, Hil F. H.; Date, Aditya G.; Vengalattore, Mukund

    2017-04-01

    We describe the experimental realization of a driven-dissipative phase transition (DPT) in a mechanical parametric amplifier and demonstrate key signatures of a critical point in the system, where the susceptibilities and relaxation time scales diverge and coincide with the spontaneous breaking of symmetry and the emergence of macroscopic order. While these observations are reminiscent of equilibrium phase transitions, it is presently an open question whether such DPTs are amenable to the conventional Landau-Ginsburg-Wilson paradigm that relies on concepts of scale invariance and universality - Indeed, recent theoretical work has predicted that DPTs can exhibit phenomenology that departs from these conventional paradigms. By quenching the system past the critical point, we measure the dynamics of the emergent ordered phase and its departure from adiabaticity, and find that our measurements are in excellent agreement with the Kibble-Zurek hypothesis. In addition to validating the KZ mechanism in a DPT for the first time, we also uniquely show that the measured critical exponents accurately reflect the interplay between the intrinsic coherent dynamics and the environmental correlations, with a clear departure from mean field exponents in the case of non-Markovian system-bath interactions. We also discuss how the techniques of reservoir engineering and the imposition of artificial environmental correlations can result in the stabilization of novel many-body quantum phases and exotic non-equilibrium states of matter.

  9. Co-Registered In Situ Secondary Electron and Mass Spectral Imaging on the Helium Ion Microscope Demonstrated Using Lithium Titanate and Magnesium Oxide Nanoparticles.

    PubMed

    Dowsett, D; Wirtz, T

    2017-09-05

    The development of a high resolution elemental imaging platform combining coregistered secondary ion mass spectrometry and high resolution secondary electron imaging is reported. The basic instrument setup and operation are discussed and in situ image correlation is demonstrated on a lithium titanate and magnesium oxide nanoparticle mixture. The instrument uses both helium and neon ion beams generated by a gas field ion source to irradiate the sample. Both secondary electrons and secondary ions may be detected. Secondary ion mass spectrometry (SIMS) is performed using an in-house developed double focusing magnetic sector spectrometer with parallel detection. Spatial resolutions of 10 nm have been obtained in SIMS mode. Both the secondary electron and SIMS image data are very surface sensitive and have approximately the same information depth. While the spatial resolutions are approximately a factor of 10 different, switching between the different images modes may be done in situ and extremely rapidly, allowing for simple imaging of the same region of interest and excellent coregistration of data sets. The ability to correlate mass spectral images on the 10 nm scale with secondary electron images on the nanometer scale in situ has the potential to provide a step change in our understanding of nanoscale phenomena in fields from materials science to life science.

  10. Fiber transport of spatially entangled photons

    NASA Astrophysics Data System (ADS)

    Löffler, W.; Eliel, E. R.; Woerdman, J. P.; Euser, T. G.; Scharrer, M.; Russell, P.

    2012-03-01

    High-dimensional entangled photons pairs are interesting for quantum information and cryptography: Compared to the well-known 2D polarization case, the stronger non-local quantum correlations could improve noise resistance or security, and the larger amount of information per photon increases the available bandwidth. One implementation is to use entanglement in the spatial degree of freedom of twin photons created by spontaneous parametric down-conversion, which is equivalent to orbital angular momentum entanglement, this has been proven to be an excellent model system. The use of optical fiber technology for distribution of such photons has only very recently been practically demonstrated and is of fundamental and applied interest. It poses a big challenge compared to the established time and frequency domain methods: For spatially entangled photons, fiber transport requires the use of multimode fibers, and mode coupling and intermodal dispersion therein must be minimized not to destroy the spatial quantum correlations. We demonstrate that these shortcomings of conventional multimode fibers can be overcome by using a hollow-core photonic crystal fiber, which follows the paradigm to mimic free-space transport as good as possible, and are able to confirm entanglement of the fiber-transported photons. Fiber transport of spatially entangled photons is largely unexplored yet, therefore we discuss the main complications, the interplay of intermodal dispersion and mode mixing, the influence of external stress and core deformations, and consider the pros and cons of various fiber types.

  11. Wearable Activity Tracker Literature Review (January 2009 - July 2016)

    DTIC Science & Technology

    2017-03-14

    heart rate. Step count was the most frequently reported metric (12 studies covering 26 devices) and had the highest correlations to actual steps taken...WAT-measured heart rate (five devices) was reviewed in two reports and correlations to reference measures were moderate (r = .67) to excellent (r...reliability data on HR or time spent in PA. Reliability tended to be assessed using correlational analyses. Criteria for interpreting the strength of the

  12. Development and psychometric characteristics of the SCI-QOL Ability to Participate and Satisfaction with Social Roles and Activities item banks and short forms.

    PubMed

    Heinemann, Allen W; Kisala, Pamela A; Hahn, Elizabeth A; Tulsky, David S

    2015-05-01

    To develop a spinal cord injury (SCI)-focused version of PROMIS and Neuro-QOL social domain item banks; evaluate the psychometric properties of items developed for adults with SCI; and report information to facilitate clinical and research use. We used a mixed-methods design to develop and evaluate Ability to Participate in Social Roles and Activities and Satisfaction with Social Roles and Activities items. Focus groups helped define the constructs; cognitive interviews helped revise items; and confirmatory factor analysis and item response theory methods helped calibrate item banks and evaluate differential item functioning related to demographic and injury characteristics. Five SCI Model System sites and one Veterans Administration medical center. The calibration sample consisted of 641 individuals; a reliability sample consisted of 245 individuals residing in the community. A subset of 27 Ability to Participate and 35 Satisfaction items demonstrated good measurement properties and negligible differential item functioning related to demographic and injury characteristics. The SCI-specific measures correlate strongly with the PROMIS and Neuro-QOL versions. Ten item short forms correlate >0.96 with the full banks. Variable-length CATs with a minimum of 4 items, variable-length CATs with a minimum of 8 items, fixed-length CATs of 10 items, and the 10-item short forms demonstrate construct coverage and measurement error that is comparable to the full item bank. The Ability to Participate and Satisfaction with Social Roles and Activities CATs and short forms demonstrate excellent psychometric properties and are suitable for clinical and research applications.

  13. Illustrating the Central Limit Theorem through Microsoft Excel Simulations

    ERIC Educational Resources Information Center

    Moen, David H.; Powell, John E.

    2005-01-01

    Using Microsoft Excel, several interactive, computerized learning modules are developed to demonstrate the Central Limit Theorem. These modules are used in the classroom to enhance the comprehension of this theorem. The Central Limit Theorem is a very important theorem in statistics, and yet because it is not intuitively obvious, statistics…

  14. Chinese Adaptation of the Bad Sobernheim Stress Questionnaire for Patients With Adolescent Idiopathic Scoliosis Under Brace Treatment.

    PubMed

    Xu, Ximing; Wang, Fei; Yang, Mingyuan; Huang, Qikai; Chang, Yifan; Wei, Xianzhao; Bai, Yushu; Li, Ming

    2015-08-01

    Bad Sobernheim Stress Questionnaire (BSSQ)-Deformity and BSSQ-Brace are the most widely used instruments for evaluating stress levels in adolescent idiopathic scoliosis (AIS) patients under brace treatment, and good reliability and validity have been demonstrated across different cultures. Great stress has been found among many adolescents, becoming a major concern for professionals. However, no previous research has addressed the cultural adaptations and psychometric testing of BSSQ-Deformity and BSSQ-Brace in China or the stress levels in AIS patients. The purposes of our study were to evaluate the cross-cultural adaptation and validation of the BSSQ-Deformity and BSSQ-Brace and to investigate stress levels in Chinese (AIS) patients under brace treatment.The original (German) versions of BSSQ-Deformity and BSSQ-Brace were cross-culturally translated according to international guidelines. Psychometric properties such as reliability and construct validity were tested. Eighty-six AIS patients were included in our study, and 50 patients paid a second visit 3 to 7 days later to test reproducibility. Cronbach α and the intraclass coefficient were determined to assess internal consistency and reproducibility. Scoliosis Research Society patient questionnaire-22 (SRS-22) was applied to evaluate construct validity.The mean BSSQ-Deformity and BSSQ-Brace scores were 15.3 and 13.4 points, respectively. Severe stress was observed in 12% of patients due to brace treatment. Item analysis demonstrated that each item was scored under a normal distribution with no redundancy. Psychometric analysis revealed excellent internal consistency (Cronbach α = 0.85 and 0.80, respectively) and reproducibility (intraclass correlation coefficient = 0.85 and 0.90, respectively) for BSSQ-Deformity and BSSQ-Brace. The correlation coefficients of BSSQ-Deformity, BSSQ-Brace and SRS-22 were 0.48 and 0.63, respectively.In conclusion, BSSQ-Deformity and BSSQ-Brace have been successfully adapted to a Chinese background and psychometrically validated with excellent reliability and construct validity. Brace wearing is considered the main cause of stress in AIS patients under brace treatment.

  15. Chinese Adaptation of the Bad Sobernheim Stress Questionnaire for Patients With Adolescent Idiopathic Scoliosis Under Brace Treatment

    PubMed Central

    Xu, Ximing; Wang, Fei; Yang, Mingyuan; Huang, Qikai; Chang, Yifan; Wei, Xianzhao; Bai, Yushu; Li, Ming

    2015-01-01

    Abstract Bad Sobernheim Stress Questionnaire (BSSQ)-Deformity and BSSQ-Brace are the most widely used instruments for evaluating stress levels in adolescent idiopathic scoliosis (AIS) patients under brace treatment, and good reliability and validity have been demonstrated across different cultures. Great stress has been found among many adolescents, becoming a major concern for professionals. However, no previous research has addressed the cultural adaptations and psychometric testing of BSSQ-Deformity and BSSQ-Brace in China or the stress levels in AIS patients. The purposes of our study were to evaluate the cross-cultural adaptation and validation of the BSSQ-Deformity and BSSQ-Brace and to investigate stress levels in Chinese (AIS) patients under brace treatment. The original (German) versions of BSSQ-Deformity and BSSQ-Brace were cross-culturally translated according to international guidelines. Psychometric properties such as reliability and construct validity were tested. Eighty-six AIS patients were included in our study, and 50 patients paid a second visit 3 to 7 days later to test reproducibility. Cronbach α and the intraclass coefficient were determined to assess internal consistency and reproducibility. Scoliosis Research Society patient questionnaire-22 (SRS-22) was applied to evaluate construct validity. The mean BSSQ-Deformity and BSSQ-Brace scores were 15.3 and 13.4 points, respectively. Severe stress was observed in 12% of patients due to brace treatment. Item analysis demonstrated that each item was scored under a normal distribution with no redundancy. Psychometric analysis revealed excellent internal consistency (Cronbach α = 0.85 and 0.80, respectively) and reproducibility (intraclass correlation coefficient = 0.85 and 0.90, respectively) for BSSQ-Deformity and BSSQ-Brace. The correlation coefficients of BSSQ-Deformity, BSSQ-Brace and SRS-22 were 0.48 and 0.63, respectively. In conclusion, BSSQ-Deformity and BSSQ-Brace have been successfully adapted to a Chinese background and psychometrically validated with excellent reliability and construct validity. Brace wearing is considered the main cause of stress in AIS patients under brace treatment. PMID:26252283

  16. A highly efficient electrocatalyst for oxygen reduction reaction: phosphorus and nitrogen co-doped hierarchically ordered porous carbon derived from an iron-functionalized polymer

    NASA Astrophysics Data System (ADS)

    Deng, Chengwei; Zhong, Hexiang; Li, Xianfeng; Yao, Lan; Zhang, Huamin

    2016-01-01

    Heteroatom-doped carbon materials have shown respectable activity for the oxygen reduction reaction (ORR) in alkaline media. However, the performances of these materials are not satisfactory for energy conversion devices, such as fuel cells. Here, we demonstrate a new type of phosphorus and nitrogen co-doped hierarchically ordered porous carbon (PNHOPC) derived from an iron-functionalized mesoporous polymer through an evaporation-induced self-assembly process that simultaneously combines the carbonization and nitrogen doping processes. The soft template and the nitrogen doping process facilitate the formation of the hierarchically ordered structure for the PNHOPC. The catalyst possesses a large surface area (1118 cm2 g-1) and a pore volume of 1.14 cm3 g-1. Notably, it exhibits excellent ORR catalytic performance, superior stability and methanol tolerance in acidic electrolytes, thus making the catalyst promising for fuel cells. The correlations between the unique pore structure and the nitrogen and phosphorus configuration of the catalysts with high catalytic activity are thoroughly investigated.Heteroatom-doped carbon materials have shown respectable activity for the oxygen reduction reaction (ORR) in alkaline media. However, the performances of these materials are not satisfactory for energy conversion devices, such as fuel cells. Here, we demonstrate a new type of phosphorus and nitrogen co-doped hierarchically ordered porous carbon (PNHOPC) derived from an iron-functionalized mesoporous polymer through an evaporation-induced self-assembly process that simultaneously combines the carbonization and nitrogen doping processes. The soft template and the nitrogen doping process facilitate the formation of the hierarchically ordered structure for the PNHOPC. The catalyst possesses a large surface area (1118 cm2 g-1) and a pore volume of 1.14 cm3 g-1. Notably, it exhibits excellent ORR catalytic performance, superior stability and methanol tolerance in acidic electrolytes, thus making the catalyst promising for fuel cells. The correlations between the unique pore structure and the nitrogen and phosphorus configuration of the catalysts with high catalytic activity are thoroughly investigated. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06749a

  17. A 12-Day Course of Imiquimod 5% for the Treatment of Actinic Keratosis: Effectiveness and Local Reactions.

    PubMed

    Serra-Guillén, C; Nagore, E; Llombart, B; Sanmartín, O; Requena, C; Calomarde, L; Guillén, C

    2018-04-01

    Imiquimod is an excellent option for patients with actinic keratosis, although its use may be limited by the long course of treatment required (4 weeks) and the likelihood of local skin reactions. The objectives of the present study were to demonstrate the effectiveness of a 12-day course of imiquimod 5% for the treatment of actinic keratosis and to examine the association between treatment effectiveness and severity of local reactions. We included patients with at least 8 actinic keratoses treated with imiquimod 5% cream for 12 consecutive days. Local reactions were classified as mild, moderate, or severe. The statistical analysis of the association between local reactions and clinical response was based on the Pearson χ 2 test and the Spearman rank correlation test. Sixty-five patients completed the study. Complete response was recorded in 52.3% and partial response in 75.4%. We found a statistically significant association between severity of the local reaction and response to treatment in both the Pearson χ 2 test and the Spearman rank correlation test. A 12-day course of imiquimod 5% proved effective for the treatment of actinic keratosis. Severity of local reactions during treatment was correlated with clinical response. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Origin of Toughness in Dispersion-Cast Nafion Membranes

    DOE PAGES

    Kim, Yu Seung; Welch, Cynthia F.; Hjelm, Rex Paul; ...

    2015-03-23

    In this study, the gelation behavior of Nafion dispersions was investigated using small-angle neutron scattering to better understand the mechanical toughness of dispersion-cast Nafion membranes. Three types of gelation were observed, depending on dispersing fluids: (i) homogeneous, thermally reversible gelation that was present in most aprotic polar dispersing fluids; (ii) inhomogeneous, thermally irreversible gelation as films, found in alcohols; and (iii) inhomogeneous, thermally irreversible gelation which precipitates in water/monohydric alcohol mixtures. The mechanical toughness of dispersion-cast Nafion membranes depends on the dispersing fluid, varying by more than 4 orders of magnitude. Excellent correlation between the critical gelation concentration and mechanicalmore » toughness was demonstrated with the Nafion membranes cast at 140 °C. Additional thermal effects among Nafion membranes cast at 190 °C were qualitatively related to the boiling point of dispersing fluids. Little correlation between mechanical toughness and percent crystalline area of Nafion was observed, suggesting that the origin of mechanical toughness of dispersion-cast Nafion membranes is due to chain entanglements rather than crystallinity. Finally, the correlation between critical gelation concentration and mechanical toughness is a new way of predicting mechanical behavior in dispersion-cast polymer systems in which both polymer-dispersing fluid and polymer–polymer interactions play a significant role in the formation of polymer chain entanglements.« less

  19. Thalamo-Sensorimotor Functional Connectivity Correlates with World Ranking of Olympic, Elite, and High Performance Athletes.

    PubMed

    Huang, Zirui; Davis, Henry Hap; Wolff, Annemarie; Northoff, Georg

    2017-01-01

    Brain plasticity studies have shown functional reorganization in participants with outstanding motor expertise. Little is known about neural plasticity associated with exceptionally long motor training or of its predictive value for motor performance excellence. The present study utilised resting-state functional magnetic resonance imaging (rs-fMRI) in a unique sample of world-class athletes: Olympic, elite, and internationally ranked swimmers ( n = 30). Their world ranking ranged from 1st to 250th: each had prepared for participation in the Olympic Games. Combining rs-fMRI graph-theoretical and seed-based functional connectivity analyses, it was discovered that the thalamus has its strongest connections with the sensorimotor network in elite swimmers with the highest world rankings (career best rank: 1-35). Strikingly, thalamo-sensorimotor functional connections were highly correlated with the swimmers' motor performance excellence, that is, accounting for 41% of the individual variance in best world ranking. Our findings shed light on neural correlates of long-term athletic performance involving thalamo-sensorimotor functional circuits.

  20. Evaluation of median nerve T2 signal changes in patients with surgically treated carpal tunnel syndrome.

    PubMed

    Samanci, Yavuz; Karagöz, Yeşim; Yaman, Mehmet; Atçı, İbrahim Burak; Emre, Ufuk; Kılıçkesmez, Nuri Özgür; Çelik, Suat Erol

    2016-11-01

    To determine the accuracy of median nerve T2 evaluation and its relation with Boston Questionnaire (BQ) and nerve conduction studies (NCSs) in pre-operative and post-operative carpal tunnel syndrome (CTS) patients in comparison with healthy volunteers. Twenty-three CTS patients and 24 healthy volunteers underwent NCSs, median nerve T2 evaluation and self-administered BQ. Pre-operative and 1st year post-operative median nerve T2 values and cross-sectional areas (CSAs) were compared both within pre-operative and post-operative CTS groups, and with healthy volunteers. The relationship between MRI findings and BQ and NCSs was analyzed. The ROC curve analysis was used for determining the accuracy. The comparison of pre-operative and post-operative T2 values and CSAs revealed statistically significant improvements in the post-operative patient group (p<0.001 for all parameters). There were positive correlations between T2 values at all levels and BQ values, and positive and negative correlations were also found regarding T2 values and NCS findings in CTS patients. The receiver operating characteristic curve analysis for defined cut-off levels of median nerve T2 values in hands with severe CTS yielded excellent accuracy at all levels. However, this accuracy could not be demonstrated in hands with mild CTS. This study is the first to analyze T2 values in both pre-operative and post-operative CTS patients. The presence of increased T2 values in CTS patients compared to controls and excellent accuracy in hands with severe CTS indicates T2 signal changes related to CTS pathophysiology and possible utilization of T2 signal evaluation in hands with severe CTS. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Comparison of ultraviolet absorbance and NO-chemiluminescence for ozone measurement in wildfire plumes at the Mount Bachelor Observatory

    NASA Astrophysics Data System (ADS)

    Gao, Honglian; Jaffe, Daniel A.

    2017-10-01

    The goal of this paper is to evaluate the accuracy of the commonly used ozone (O3) instrument (the ultraviolet (UV) photometer) against a Federal Reference Method (Nitric Oxide -chemiluminescence) for ozone measurement in wildfire smoke plumes. We carried out simultaneous ozone measurement with two UV O3 photometers and one nitric oxide-chemiluminescence (NO-CL) ozone detectors during wildfire season (Aug. 1-Sept. 30) in 2015 at the Mount Bachelor Observatory (MBO, 2763 m above mean sea level, Oregon, USA). The UV O3 shows good agreement and excellent correlation to NO-CL O3, with linear regression slopes close to unity and R2 of 0.92 for 1-h average data and R2 of 0.93 for O3 daily maximum 8-h average (MDA8). During this two-month period we identified 35 wildfire events. Ozone enhancements in those wildfire plumes measured by NO-CL O3 and UV O3 monitors also show good agreement and excellent linear correlation, with a slope and R2 of 1.03 and 0.86 for O3 enhancements (ΔO3) and 1.00 and 0.98 for carbon monoxide (CO)-normalized ozone enhancement ratios (ΔO3/ΔCO), respectively. Overall, the UV O3 was found to have a positive bias of 4.7 ± 2.8 ppbv compared to the NO-CL O3. The O3 bias between NO-CL O3 and UV O3 is independent of wildfire plume tracers such as CO, particulate matter (PM1), aerosol scattering, and ultrafine particles. The results demonstrate that the UV O3 absorbance method is reliable, even in highly concentrated wildfire plumes.

  2. Exact thermal density functional theory for a model system: Correlation components and accuracy of the zero-temperature exchange-correlation approximation

    DOE PAGES

    Smith, J. C.; Pribram-Jones, A.; Burke, K.

    2016-06-14

    Thermal density functional theory calculations often use the Mermin-Kohn-Sham scheme, but employ ground-state approximations to the exchange-correlation (XC) free energy. In the simplest solvable nontrivial model, an asymmetric Hubbard dimer, we calculate the exact many-body energies and the exact Mermin-Kohn-Sham functionals for this system and extract the exact XC free energy. For moderate temperatures and weak correlation, we find this approximation to be excellent. Here we extract various exact free-energy correlation components and the exact adiabatic connection formula.

  3. Exact thermal density functional theory for a model system: Correlation components and accuracy of the zero-temperature exchange-correlation approximation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, J. C.; Pribram-Jones, A.; Burke, K.

    Thermal density functional theory calculations often use the Mermin-Kohn-Sham scheme, but employ ground-state approximations to the exchange-correlation (XC) free energy. In the simplest solvable nontrivial model, an asymmetric Hubbard dimer, we calculate the exact many-body energies and the exact Mermin-Kohn-Sham functionals for this system and extract the exact XC free energy. For moderate temperatures and weak correlation, we find this approximation to be excellent. Here we extract various exact free-energy correlation components and the exact adiabatic connection formula.

  4. Statistical analysis of atmospheric turbulence about a simulated block building

    NASA Technical Reports Server (NTRS)

    Steely, S. L., Jr.

    1981-01-01

    An array of towers instrumented to measure the three components of wind speed was used to study atmospheric flow about a simulated block building. Two-point spacetime correlations of the longitudinal velocity component were computed along with two-point spatial correlations. These correlations are in good agreement with fundamental concepts of fluid mechanics. The two-point spatial correlations computed directly were compared with correlations predicted by Taylor's hypothesis and excellent agreement was obtained at the higher levels which were out of the building influence. The correlations fall off significantly in the building wake but recover beyond the wake to essentially the same values in the undisturbed, higher regions.

  5. Short versions of two specific phobia measures: The snake and the spider questionnaires.

    PubMed

    Zsido, Andras N; Arato, Nikolett; Inhof, Orsolya; Janszky, Jozsef; Darnai, Gergely

    2018-03-01

    Zoophobias are the most prevalent form of specific phobia worldwide. Two of the most widely used measures, the Snake Questionnaire (SNAQ) and Spider Questionnaire (SPQ) are good indicators of specific fears, but researchers have recognised that shorter, yet nevertheless reliable measures are needed. Hence the aims of this research were to develop short forms of the SNAQ and SPQ using item response theory and to use receiver operating characteristic (ROC) curve analyses to determine cut-offs for use in future research. Twelve-item versions of both scales (SNAQ-12 and SPQ-12) demonstrated excellent discrimination along the latent continuum in a sample of 1354 people. The SNAQ-12 and SPQ-12 showed excellent reliability and were highly correlated with the corresponding full-length scale. The scales discriminated between participants who reported snake (3.25%) or spider (8.05%) phobia and those who did not. Further analyses revealed that non-phobic women report higher fear of both snakes and spiders than do men, but this difference was not present in phobics. These findings suggest that the SNAQ-12 and SPQ-12 have considerable strengths, including shorter assessment and scoring times, whilst retaining high reliability and potential utility as a clinical screening tool. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A Systematic Approach to Achieving High Performance Hybrid Lighting Phosphors with Excellent Thermal- and Photostability

    DOE PAGES

    Fang, Yang; Liu, Wei; Teat, Simon J.; ...

    2016-12-07

    We have designed and synthesized a family of high-performance inorganic-organic hybrid phosphor materials composed of extended and robust networks of one-, two- and three-dimensions. Following a bottom-up solution-based synthetic approach, these structures are constructed by connecting highly emissive Cu 4I 4 cubic clusters via carefully selected ligands that form strong Cu-N bonds. They emit intensive yellow-orange light with high luminescence quantum efficiency, coupled with large Stokes shift which greatly reduces self-absorption. They also demonstrate exceptionally high framework- and photo-stability, comparable to those of commercial phosphors. The high stabilities are the result of significantly enhanced Cu-N bonds, as confirmed by themore » DFT binding energy and electron density calculations. Possible emission mechanisms are analyzed based on the results of theoretical calculations and optical experiments. Two-component white phosphors obtained by blending blue and yellow emitters reach an internal quantum yield (IQY) as high as 82% and correlated color temperature (CCT) as low as 2534 K. The performance level of this sub-family exceeds all other types of Cu-I based hybrid systems. The combined advantages make them excellent candidates as alternative rare-earth element (REE) free phosphors for possible use in energy-efficient lighting devices.« less

  7. All-solid-state flexible supercapacitors fabricated with bacterial nanocellulose papers, carbon nanotubes, and triblock-copolymer ion gels.

    PubMed

    Kang, Yu Jin; Chun, Sang-Jin; Lee, Sung-Suk; Kim, Bo-Yeong; Kim, Jung Hyeun; Chung, Haegeun; Lee, Sun-Young; Kim, Woong

    2012-07-24

    We demonstrate all-solid-state flexible supercapacitors with high physical flexibility, desirable electrochemical properties, and excellent mechanical integrity, which were realized by rationally exploiting unique properties of bacterial nanocellulose, carbon nanotubes, and ionic liquid based polymer gel electrolytes. This deliberate choice and design of main components led to excellent supercapacitor performance such as high tolerance against bending cycles and high capacitance retention over charge/discharge cycles. More specifically, the performance of our supercapacitors was highly retained through 200 bending cycles to a radius of 3 mm. In addition, the supercapacitors showed excellent cyclability with C(sp) (~20 mF/cm(2)) reduction of only <0.5% over 5000 charge/discharge cycles at the current density of 10 A/g. Our demonstration could be an important basis for material design and development of flexible supercapacitors.

  8. Synthesis of N-doped TiO2 Using Guanidine Nitrate: An Excellent Visible Light Photocatalyst

    EPA Science Inventory

    An excellent visible light active nitrogen-rich TiO2 photocatalyst have been synthesized by using guanidine nitrate as the doping material. The catalytic efficiency of the catalyst has been demonstrated by the decomposition of the dye, methyl orange (MO), and the pollutant, 2,4 d...

  9. Using Excel's Matrix Operations to Facilitate Reciprocal Cost Allocations

    ERIC Educational Resources Information Center

    Leese, Wallace R.; Kizirian, Tim

    2009-01-01

    The reciprocal method of service department cost allocation requires linear equations to be solved simultaneously. These computations are often so complex as to cause the abandonment of the reciprocal method in favor of the less sophisticated direct or step-down methods. Here is a short example demonstrating how Excel's sometimes unknown matrix…

  10. Excellent Companies and Coalition-Building among the Fortune 500: A Value- and Relationship-Based Theory.

    ERIC Educational Resources Information Center

    Wilson, Laurie J.

    1994-01-01

    Discusses ways a revolution in business management emphasizing people, values, integrity, and communication should also change the approach to public relations. Reviews research to demonstrate that coalition companies possess the characteristics of excellent companies. Argues that perhaps this community relations function will lead from the…

  11. Validation of Toolkit After-Death Bereaved Family Member Interview.

    PubMed

    Teno, J M; Clarridge, B; Casey, V; Edgman-Levitan, S; Fowler, J

    2001-09-01

    The purpose of this study was to examine the reliability and validity of the Toolkit After-Death Bereaved Family Member Interview to measure quality of care at the end of life from the unique perspective of family members. The survey included proposed problem scores (a count of the opportunity to improve the quality of care) and scales. Data were collected through a retrospective telephone survey with a family member who was interviewed between 3 and 6 months after the death of the patient. The setting was an outpatient hospice service, a consortium of nursing homes, and a hospital in New England. One hundred fifty-six family members from across these settings participated. The 8 proposed domains of care, as represented by problem scores or scales, were based on a conceptual model of patient-focused, family-centered medical care. The survey design emphasized face validity in order to provide actionable information to health care providers. A correlational and factor analysis was undertaken of the 8 proposed problem scores or scales. Cronbach's alpha scores varied from 0.58 to 0.87, with two problem scores (each of which had only 3 survey items) having a low alpha of 0.58. The mean item-to-total correlations for the other problem scores varied from 0.36 to 0.69, and the mean item-to-item correlations were between 0.32 and 0.70. The proposed problem scores or scales, with the exception of closure and advance care planning, demonstrated a moderate correlation (i.e., from 0.44 to 0.52) with the overall rating of satisfaction (as measured by a five-point, "excellent" to "poor" scale). Family members of persons who died with hospice service reported fewer problems in each of the six domains of medical care, gave a higher rating of the quality of care, and reported higher self-efficacy in caring for their loved ones. These results indicate that 7 of the 8 proposed problem scores or scales demonstrated psychometric properties that warrant further testing. The domain of closure demonstrated a poor correlation with overall satisfaction and requires further work. This survey could provide information to help guide quality improvement efforts to enhance the care of the dying.

  12. NASA's Suborbital Center of Excellence - reaching young minds and crafting the future

    NASA Astrophysics Data System (ADS)

    Cathey, H.; Hottman, S.; Hansen, K.

    The NASA Suborbital Center of Excellence is charting new territory. From an idea to promote science and engineering education and outreach, the Suborbital Center of Excellence is working toward the objective of increasing numbers of college graduates choosing a career in suborbital programs. Approaches to excite university students to want to pursue these careers through relevant and useful work experiences will be highlighted. Suborbital platforms include balloons, sounding rockets, research aircraft (manned and remotely piloted vehicles) and small satellites. Key components of this are the Suborbital Center of Excellence co-op program and the support of Engineering ``Capstone'' projects. A number of these projects and programs have been supported during the past year. Highlights of these student hands-on learning experiences will be presented. The projects have included diverse projects ranging from work on a power beaming demonstration and autonomous aircraft control logic to the development of light weight pressure vessels for balloon flights based on ULDB spin-off technology, and balloon drop sonde development. Preparing these future Scientists and Engineers involves the investment of time, energy, and resources. The Suborbital Center of Excellence is uniquely positioned to do this. Future programs and initiatives will be presented. The Suborbital Center of Excellence is evolving, meeting the needs to promote science and engineering education and outreach. Educational outreach initiatives for young children to university students will also be presented. These include hands-on experiments, demonstrations, and suborbital educational materials.

  13. Stress-stress fluctuation formula for elastic constants in the NPT ensemble

    NASA Astrophysics Data System (ADS)

    Lips, Dominik; Maass, Philipp

    2018-05-01

    Several fluctuation formulas are available for calculating elastic constants from equilibrium correlation functions in computer simulations, but the ones available for simulations at constant pressure exhibit slow convergence properties and cannot be used for the determination of local elastic constants. To overcome these drawbacks, we derive a stress-stress fluctuation formula in the NPT ensemble based on known expressions in the NVT ensemble. We validate the formula in the NPT ensemble by calculating elastic constants for the simple nearest-neighbor Lennard-Jones crystal and by comparing the results with those obtained in the NVT ensemble. For both local and bulk elastic constants we find an excellent agreement between the simulated data in the two ensembles. To demonstrate the usefulness of the formula, we apply it to determine the elastic constants of a simulated lipid bilayer.

  14. The factor structure and construct validity of the inventory of callous-unemotional traits in Chinese undergraduate students

    PubMed Central

    Gao, Yu; Deng, Jiaxin; Lai, Hongyu; Deng, Qiaowen; Armour, Cherie

    2017-01-01

    The current study assesses the factor structure and construct validity of the self-reported Inventory of Callous–Unemotional Traits (ICU) in 637 Chinese community adults (mean age = 25.98, SD = 5.79). A series of theoretical models proposed in previous studies were tested through confirmatory factor analyses. Results indicated that a shortened form that consists of 11 items (ICU-11) to assess callousness and uncaring factors has excellent overall fit. Additionally, correlations with a wide range of external variables demonstrated that this shortened form has similar construct validity compared to the original ICU. In conclusion, our findings suggest that the ICU-11 may be a promising self-report tool that could be a good substitute for the original form to assess callous-uncaring traits in adults. PMID:29216240

  15. Control of gaseous pollution via the leaves of non-edible trees

    NASA Astrophysics Data System (ADS)

    Al-Maliky, S. J. B.

    2015-11-01

    The accelerated increase of the use of various transportation means, industrial machinery and other power consuming technologies has led to tremendous degradation of outdoor air quality all around the world. Green solution was tested here as an innovative gas control mean via non edible Myrtus communis green leaves as natural sorption media. Statistical analyses were applied in order to examine the correlation between various parameters of this study. The tests of gas records around the tree that was targeted by a gas stream of 5 KW power generators have demonstrated an excellent gas control role of the green leaves, with average efficiencies of about 75% and 82% for the removal of Nitrogen Dioxide and Carbon Monoxide, respectively. An interesting finding of this research was that the sorption role of green leaves has promoted their sizes and Chlorophyll Content Index.

  16. A combined ultra-wideline solid-state NMR and DFT study of 137Ba electric field gradient tensors in barium compounds

    NASA Astrophysics Data System (ADS)

    O'Dell, Luke A.; Moudrakovski, Igor L.

    2013-04-01

    Ultra-wideline 137Ba solid-state (SS) NMR spectra have been obtained from a series of five barium compounds (BaSO4, BaMoO4, Ba(CH3COO)2, Ba(OH)2·8H2O and α-Ba2P2O7), using the broadband WURST-QCPMG pulse sequence and magnetic field of 21.1 T. The signals from the two distinct crystallographic sites in α-Ba2P2O7 are resolved, with one of them demonstrating a CQ of 42.3 ± 0.3 MHz, the largest obtained for 137Ba in a powder. The quadrupolar parameters reported in this work are in excellent agreement with the DFT calculations and correlate well with those previously reported by Hamaed et al. (2010) [24].

  17. The Afghan symptom checklist: a culturally grounded approach to mental health assessment in a conflict zone.

    PubMed

    Miller, Kenneth E; Omidian, Patricia; Quraishy, Abdul Samad; Quraishy, Naseema; Nasiry, Mohammed Nader; Nasiry, Seema; Karyar, Nazar Mohammed; Yaqubi, Abdul Aziz

    2006-10-01

    This article describes a methodology for developing culturally grounded assessment measures in conflict and postconflict situations. A mixed-method design was used in Kabul, Afghanistan, to identify local indicators of distress and develop the 22-item Afghan Symptom Checklist (ASCL). The ASCL contains several indigenous items and items familiar to Western mental health professionals. The ASCL was pilot tested and subsequently administered to 324 adults in 8 districts of Kabul. It demonstrated excellent reliability (alpha=.93) and good construct validity, correlating strongly with a measure of exposure to war-related violence and loss (r=.70). Results of the survey indicate moderate levels of distress among Afghan men and markedly higher levels of distress and impaired functioning among women (and widows in particular). (c) 2007 APA, all rights reserved

  18. Cartilage Regeneration in Full-Thickness Patellar Chondral Defects Treated with Particulated Juvenile Articular Allograft Cartilage: An MRI Analysis.

    PubMed

    Grawe, Brian; Burge, Alissa; Nguyen, Joseph; Strickland, Sabrina; Warren, Russell; Rodeo, Scott; Shubin Stein, Beth

    2017-10-01

    Background Full-thickness cartilage lesions of the patella represent a common source of pain and dysfunction. Previously reported surgical treatment options include marrow stimulation, cell-based treatments, and osteochondral transfer. Minced juvenile allograft cartilage is a novel treatment option that allows for a single stage approach for these lesions. Hypothesis Particulated juvenile allograft cartilage (PJAC) for the treatment of chondral defects of the patella would offer acceptable lesion fill rates, mature over time, and not be associated with any negative biologic effects on the surrounding tissue. Methods A retrospective chart review of prospectively collected data was conducted to identify consecutive patients who were treated with PJAC for a full thickness symptomatic cartilage lesion. Qualitative (fast spin echo) and quantitative (T2 mapping) magnetic resonance imaging (MRI) was undertaken at the 6-, 12-, and 24-month postoperative mark. Numerous patient, lesion, and graft specific factors were assessed against MRI scores and percent defect fill of the graft. Graft maturation over time was also assessed. Results Forty-five patients total were included in the study. Average age at the time of surgery was 26.5 years (range 13-45 years), average lesion size was 208 mm 2 (range 4-500 mm 2 ), and average donor age was 49.5 months (range 3-120 months). Sixty percent of the patients were female, while 93% of all patients underwent a concomitant procedure at the time of the index operation. Six-month MRI findings revealed that no patient-, graft-, or donor-specific factors correlated with MR scores, and 82% of the knees demonstrated good to excellent fill. Twelve-month MRI findings revealed that T2 relaxation times of deep graft demonstrated negative correlation with patient age ( P = 0.049) and donor age ( P = 0.006), the integration zone showed a negative correlation with donor age ( P = 0.026). In all, 85% of patients at 12 months displayed good to moderate fill of the graft. At 24 months, patient age demonstrated negative correlation with average T2 relaxation times of the deep and superficial graft ( P = 0.005; P = 0.0029) and positive correlation with the superficial zone of the adjacent cartilage ( P = 0.001). Donor age showed negative correlation with grayscale score ( P = 0.004) and T2 relaxation times at deep integration zone ( P = 0.018). T2 relaxation times of deep and superficial graft and integration zone improved over time ( P < 0.001) and between each time point. Conclusions Particulated juvenile allograft tissue appears to be an acceptable reconstructive option for full-thickness cartilage lesions of the patella, offering satisfactory tissue defect fill at 6, 12, and 24 months after surgery. Imaging of the repaired cartilage demonstrates progressive graft maturation over time.

  19. Correlation between histological outcome and surgical cartilage repair technique in the knee: A meta-analysis.

    PubMed

    DiBartola, Alex C; Everhart, Joshua S; Magnussen, Robert A; Carey, James L; Brophy, Robert H; Schmitt, Laura C; Flanigan, David C

    2016-06-01

    Compare histological outcomes after microfracture (MF), autologous chondrocyte implantation (ACI), and osteochondral autograft transfer (OATS). Literature review using PubMed MEDLINE, SCOPUS, Cumulative Index for Nursing and Allied Health Literature (CINAHL), and Cochrane Collaboration Library. Inclusion criteria limited to English language studies International Cartilage Repair Society (ICRS) grading criteria for cartilage analysis after ACI (autologous chondrocyte implantation), MF (microfracture), or OATS (osteochondral autografting) repair techniques. Thirty-three studies investigating 1511 patients were identified. Thirty evaluated ACI or one of its subtypes, six evaluated MF, and seven evaluated OATS. There was no evidence of publication bias (Begg's p=0.48). No statistically significant correlation was found between percent change in clinical outcome and percent biopsies showing ICRS Excellent scores (R(2)=0.05, p=0.38). Percent change in clinical outcome and percent of biopsies showing only hyaline cartilage were significantly associated (R(2)=0.24, p=0.024). Mean lesion size and histological outcome were not correlated based either on percent ICRS Excellent (R(2)=0.03, p=0.50) or percent hyaline cartilage only (R(2)=0.01, p=0.67). Most common lesion location and histological outcome were not correlated based either on percent ICRS Excellent (R(2)=0.03, p=0.50) or percent hyaline cartilage only (R(2)=0.01, p=0.67). Microfracture has poorer histologic outcomes than other cartilage repair techniques. OATS repairs primarily are comprised of hyaline cartilage, followed closely by cell-based techniques, but no significant difference was found cartilage quality using ICRS grading criteria among OATS, ACI-C, MACI, and ACI-P. IV, meta-analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. ASSOCIATIONS BETWEEN THREE CLINICAL ASSESSMENT TOOLS FOR POSTURAL STABILITY

    PubMed Central

    Saxion, Casie E.; Cameron, Kenneth L.; Gerber, J. Parry

    2010-01-01

    Study Design: Clinical Measurement, Correlation, Reliability Objectives: To assess the relationship between the Single Leg Balance (SLB), modified Balance Error Scoring System (mBESS), and modified Star Excursion Balance (mSEBT) tests and secondarily to assess inter-rater and test-retest reliability of these tests. Background: Ankle sprains often result in chronic instability and dysfunction. Several clinical tests assess postural deficits as a potential cause of this dysfunction; however, limited information exists pertaining to the relationship that these tests have with one another. Methods: Two independent examiners measured the performance of 34 healthy participants completing the SLB Test, mBESS test, and mSEBT at two different time periods. The relationship between tests was assessed using the Pearson Correlation and Fisher's Exact Tests. Inter-rater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Kappa statistics. Results: A significant correlation (r = -0.35) was observed between the mSEBT and the mBESS. Fisher's Exact Test showed a significant association between the SLB Test and mBESS (P = .048), but no association between the SLB and mSEBT (P = 1.000). Inter-rater reliability was excellent for the mSEBT and fair for the mBESS (ICCs of .91 and .61 respectively). Excellent agreement was observed between raters for the SLB test (k = 1.00). Test-retest reliability was excellent for the mSEBT (ICC = 0.98) and fair for the mBESS (ICC = 0.74). There was poor test-retest agreement for the SLB test (k = .211). Conclusion: There was a significant relationship observed between the SLB Test, mBESS test, and mSEBT: however; strength of association measures showed limited overlap between these tests. This suggests that these tests are interrelated but may not assess equal components of postural stability. PMID:21589668

  1. Reliability and concurrent validity of the adapted Chinese version of Scoliosis Research Society-22 (SRS-22) questionnaire.

    PubMed

    Cheung, Kenneth M C; Senkoylu, Alpaslan; Alanay, Ahmet; Genc, Yasemin; Lau, Sarah; Luk, Keith D

    2007-05-01

    Validation study to define validity and reliability of an adapted and translated questionnaire. Assessment of the concurrent validity and reliability of a Chinese version of SRS-22 outcome instrument. No valid health-related quality of life (HRQL) outcome instrument exists for patients with spinal deformity in Chinese. The modified SRS-22 questionnaire was proven to be an appropriate outcome instrument in English, and has already been translated and validated in several other languages. The English version of the SRS-22 questionnaire was adapted to Chinese according to the International Quality of Life Assessment Project guidelines. To assess reliability, 48 subjects with adolescent idiopathic scoliosis (mean age, 16.5 years) filled the questionnaire on 2 separate occasions (Group 1). To assess concurrent validity, 50 subjects (mean age, 21 years) filled in the same questionnaire and a previously validated Chinese version of the Short Form-36 (SF36) questionnaire (Group 2). Internal consistency, reproducibility and concurrent validity were determined with Cronbach's alpha coefficient, interclass correlation coefficient and Pearson correlation coefficient, respectively. Cronbach's alpha coefficient for the 4 major domains (function/activity, pain, self-image/appearance and mental health) were high. Intraclass correlation was also excellent for all domains. For concurrent validity, excellent correlation was found in 1 domain, good in 12 domains, moderate in 3 domains, and poor in 1 domain of the 17 relevant domains. Both cultural adaptation and linguistic translation are essential in any attempt to use a HRQL questionnaire across cultures. The Chinese version of the SRS-22 outcome instrument has satisfactory internal consistency and excellent reproducibility. It is ready for use in clinical studies on idiopathic scoliosis in Chinese-speaking societies.

  2. Evaluation of dyskinesias in a pilot, randomized, placebo-controlled trial of remacemide in advanced Parkinson disease.

    PubMed

    2001-10-01

    Long-term levodopa therapy for Parkinson disease commonly results in motor complications including "on-off" fluctuations and dyskinesias, but it is still unclear how best to assess treatment effects on dyskinesias in clinical trials. To compare several methods of rating levodopa-induced dyskinesias to evaluate the effect of remacemide hydrochloride treatment in patients with advanced Parkinson disease. Two-week multicenter randomized, double-blind, placebo-controlled, parallel-group study. Five academic sites of the Parkinson Study Group. Thirty-nine subjects at least 30 years old with idiopathic Parkinson disease and disabling dyskinesias. Randomly received daily doses of 150 mg, 300 mg, or 600 mg of remacemide hydrochloride or matching placebo for 2 weeks. The dyskinesia rating scales used were the Modified Goetz Dyskinesia Rating scale (MGDRS), a newly created Lang-Fahn Activities of Daily Living Dyskinesia scale (LFADLDS), and diary dyskinesia ratings. Patient and investigator diaries showed excellent agreement in dyskinesia ratings. The MGDRS score correlated with clinic diary ratings of the percentage of "on" time with dyskinesias, and the LFADLDS score correlated with home and clinic diary assessments of percentage of on time with severe dyskinesias. The MGDRS score did not correlate highly with the LFADLDS score. This pilot study also validated previous results demonstrating the safety and tolerability of remacemide treatment for advanced Parkinson disease but did not result in any demonstrable improvement or worsening in dyskinesia measures. Diaries may provide a valid means of evaluating dyskinesias in clinical trials for Parkinson disease, but there remain other aspects of dyskinesias, as assessed by the MGDRS and LFADLDS, that are not reflected in diary ratings.

  3. Radiotracer Imaging Allows for Noninvasive Detection and Quantification of Abnormalities in Angiosome Foot Perfusion in Diabetic Patients With Critical Limb Ischemia and Nonhealing Wounds

    PubMed Central

    Alvelo, Jessica L.; Papademetris, Xenophon; Mena-Hurtado, Carlos; Jeon, Sangchoon; Sumpio, Bauer E.; Sinusas, Albert J.

    2018-01-01

    Background: Single photon emission computed tomography (SPECT)/computed tomography (CT) imaging allows for assessment of skeletal muscle microvascular perfusion but has not been quantitatively assessed in angiosomes, or 3-dimensional vascular territories, of the foot. This study assessed and compared resting angiosome foot perfusion between healthy subjects and diabetic patients with critical limb ischemia (CLI). Additionally, the relationship between SPECT/CT imaging and the ankle–brachial index—a standard tool for evaluating peripheral artery disease—was assessed. Methods and Results: Healthy subjects (n=9) and diabetic patients with CLI and nonhealing ulcers (n=42) underwent SPECT/CT perfusion imaging of the feet. CT images were segmented into angiosomes for quantification of relative radiotracer uptake, expressed as standardized uptake values. Standardized uptake values were assessed in ulcerated angiosomes of patients with CLI and compared with whole-foot standardized uptake values in healthy subjects. Serial SPECT/CT imaging was performed to assess uptake kinetics of technetium-99m-tetrofosmin. The relationship between angiosome perfusion and ankle–brachial index was assessed via correlational analysis. Resting perfusion was significantly lower in CLI versus healthy subjects (P=0.0007). Intraclass correlation coefficients of 0.95 (healthy) and 0.93 (CLI) demonstrated excellent agreement between serial perfusion measurements. Correlational analysis, including healthy and CLI subjects, demonstrated a significant relationship between ankle–brachial index and SPECT/CT (P=0.01); however, this relationship was not significant for diabetic CLI patients only (P=0.2). Conclusions: SPECT/CT imaging assesses regional foot perfusion and detects abnormalities in microvascular perfusion that may be undetectable by conventional ankle–brachial index in patients with diabetes mellitus. SPECT/CT may provide a novel approach for evaluating responses to targeted therapies. PMID:29748311

  4. Dynamic mode decomposition for plasma diagnostics and validation.

    PubMed

    Taylor, Roy; Kutz, J Nathan; Morgan, Kyle; Nelson, Brian A

    2018-05-01

    We demonstrate the application of the Dynamic Mode Decomposition (DMD) for the diagnostic analysis of the nonlinear dynamics of a magnetized plasma in resistive magnetohydrodynamics. The DMD method is an ideal spatio-temporal matrix decomposition that correlates spatial features of computational or experimental data while simultaneously associating the spatial activity with periodic temporal behavior. DMD can produce low-rank, reduced order surrogate models that can be used to reconstruct the state of the system with high fidelity. This allows for a reduction in the computational cost and, at the same time, accurate approximations of the problem, even if the data are sparsely sampled. We demonstrate the use of the method on both numerical and experimental data, showing that it is a successful mathematical architecture for characterizing the helicity injected torus with steady inductive (HIT-SI) magnetohydrodynamics. Importantly, the DMD produces interpretable, dominant mode structures, including a stationary mode consistent with our understanding of a HIT-SI spheromak accompanied by a pair of injector-driven modes. In combination, the 3-mode DMD model produces excellent dynamic reconstructions across the domain of analyzed data.

  5. Dynamic mode decomposition for plasma diagnostics and validation

    NASA Astrophysics Data System (ADS)

    Taylor, Roy; Kutz, J. Nathan; Morgan, Kyle; Nelson, Brian A.

    2018-05-01

    We demonstrate the application of the Dynamic Mode Decomposition (DMD) for the diagnostic analysis of the nonlinear dynamics of a magnetized plasma in resistive magnetohydrodynamics. The DMD method is an ideal spatio-temporal matrix decomposition that correlates spatial features of computational or experimental data while simultaneously associating the spatial activity with periodic temporal behavior. DMD can produce low-rank, reduced order surrogate models that can be used to reconstruct the state of the system with high fidelity. This allows for a reduction in the computational cost and, at the same time, accurate approximations of the problem, even if the data are sparsely sampled. We demonstrate the use of the method on both numerical and experimental data, showing that it is a successful mathematical architecture for characterizing the helicity injected torus with steady inductive (HIT-SI) magnetohydrodynamics. Importantly, the DMD produces interpretable, dominant mode structures, including a stationary mode consistent with our understanding of a HIT-SI spheromak accompanied by a pair of injector-driven modes. In combination, the 3-mode DMD model produces excellent dynamic reconstructions across the domain of analyzed data.

  6. Development Status of High-Thrust Density Electrostatic Engines

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Haag, Thomas W.; Foster, John E.; Young, Jason A.; Crofton, Mark W.

    2017-01-01

    Ion thruster technology offers the highest performance and efficiency of any mature electric propulsion thruster. It has by far the highest demonstrated total impulse of any technology option, demonstrated at input power levels appropriate for primary propulsion. It has also been successfully implemented for primary propulsion in both geocentric and heliocentric environments, with excellent ground/in-space correlation of both its performance and life. Based on these attributes there is compelling reasoning to continue the development of this technology: it is a leading candidate for high power applications; and it provides risk reduction for as-yet unproven alternatives. As such it is important that the operational limitations of ion thruster technology be critically examined and in particular for its application to primary propulsion its capabilities relative to thrust the density and thrust-to-power ratio be understood. This publication briefly addresses some of the considerations relative to achieving high thrust density and maximizing thrust-to-power ratio with ion thruster technology, and discusses the status of development work in this area being executed under a collaborative effort among NASA Glenn Research Center, the Aerospace Corporation, and the University of Michigan.

  7. Study of Tissue Phantoms, Tissues, and Contrast Agent with the Biophotoacoustic Radar and Comparison to Ultrasound Imaging for Deep Subsurface Imaging

    NASA Astrophysics Data System (ADS)

    Alwi, R.; Telenkov, S.; Mandelis, A.; Gu, F.

    2012-11-01

    In this study, the imaging capability of our wide-spectrum frequency-domain photoacoustic (FD-PA) imaging alias "photoacoustic radar" methodology for imaging of soft tissues is explored. A practical application of the mathematical correlation processing method with relatively long (1 ms) frequency-modulated optical excitation is demonstrated for reconstruction of the spatial location of the PA sources. Image comparison with ultrasound (US) modality was investigated to see the complementarity between the two techniques. The obtained results with a phased array probe on tissue phantoms and their comparison to US images demonstrated that the FD-PA technique has strong potential for deep subsurface imaging with excellent contrast and high signal-to-noise ratio. FD-PA images of blood vessels in a human wrist and an in vivo subcutaneous tumor in a rat model are presented. As in other imaging modalities, the employment of contrast agents is desirable to improve the capability of medical diagnostics. Therefore, this study also evaluated and characterized the use of Food and Drug Administration (FDA)-approved superparamagnetic iron oxide nanoparticles (SPION) as PA contrast agents.

  8. Development of a modified instrument to measure anticipatory grieving in Jordanian parents of children diagnosed with cancer: the Marwit and Meuser Caregiver Inventory Childhood Cancer.

    PubMed

    Al-Gamal, Ekhlas; Long, Tony; Livesley, Joan

    2009-01-01

    The purpose of this article is to report on the development and field testing for validity and reliability of a modified version of the Marwit and Meuser Caregiver Inventory (MM-CGI) for the assessment of anticipatory grief among Jordanian parents of children with cancer (the MM-CGI Childhood Cancer). In 2006, a 50-item MM-CGI Childhood Cancer was administered to 140 Jordanian parents living with a child with cancer. The Cronbach alpha coefficient for the total instrument was .95, and Cronbach alpha coefficients for each of the 3 subscales was .91 for personal sacrifice burden, .90 for heartfelt sadness and longing, and .86 for worry and felt isolation. The construct validity of this instrument was supported by demonstrating a significant and positive correlation with the Anticipatory Grief Scale. The MM-CGI Childhood Cancer demonstrated strong convergent validity and excellent internal consistency reliability. However, further testing with a larger sample to facilitate factor analysis is needed to complete the validation process.

  9. Identification and characterization of novel benzil (diphenylethane-1,2-dione) analogues as inhibitors of mammalian carboxylesterases.

    PubMed

    Wadkins, Randy M; Hyatt, Janice L; Wei, Xin; Yoon, Kyoung Jin P; Wierdl, Monika; Edwards, Carol C; Morton, Christopher L; Obenauer, John C; Damodaran, Komath; Beroza, Paul; Danks, Mary K; Potter, Philip M

    2005-04-21

    Carboxylesterases (CE) are ubiquitous enzymes responsible for the metabolism of xenobiotics. Because the structural and amino acid homology among esterases of different classes, the identification of selective inhibitors of these proteins has proved problematic. Using Telik's target-related affinity profiling (TRAP) technology, we have identified a class of compounds based on benzil (1,2-diphenylethane-1,2-dione) that are potent CE inhibitors, with K(i) values in the low nanomolar range. Benzil and 30 analogues demonstrated selective inhibition of CEs, with no inhibitory activity toward human acetylcholinesterase or butyrylcholinesterase. Analysis of structurally related compounds indicated that the ethane-1,2-dione moiety was essential for enzyme inhibition and that potency was dependent on the presence of, and substitution within, the benzene ring. 3D-QSAR analyses of these benzil analogues for three different mammalian CEs demonstrated excellent correlations of observed versus predicted K(i) (r(2) > 0.91), with cross-validation coefficients (q(2)) of 0.9. Overall, these results suggest that selective inhibitors of CEs with potential for use in clinical applications can be designed.

  10. Oil exploration and development in Marib/Al Jawf basin, Yemen Arab Republic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maycock, I.D.

    1986-07-01

    In 1981, Yemen Hunt Oil Company (YHOC) negotiated a production-sharing agreement covering 12,600 km/sup 2/ in the northeast part of the Yemen Arab Republic. A reconnaissance seismic program of 1864 km acquired in 1982 revealed the presence of a major half graben, designated the Marib/Al Jawf basin by YHOC. A sedimentary section up to 18,000 ft thick has been recognized. Geologic field mapping identified Jurassic carbonates covered by Cretaceous sands overlying Permian glaciolacustrine sediments, Paleozoic sandstones, or Precambrian basement. The first well drilled in 1984, aimed at a possible Jurassic carbonate objective, encountered hydrocarbon-bearing sands in the Jurassic-Cretaceous transition betweenmore » 5000 and 6000 ft. A successful appraisal drilling program has demonstrated satisfactory lateral reservoir continuity. Further wildcat drilling demonstrates macro-unit correlation within the eastern part of the basin. Rapid basin development apparently commenced in the late Kimmeridgian, culminating with the deposition of Tithonian evaporites. Available geochemical analysis indicates sourcing from restricted-basin sediments. Excellent traps, reservoirs, and source beds underlying the Tithonian evaporites indicate that a significant new petroliferous province is present.« less

  11. Reliability and a correlational analysis of the 6MWT, ten-meter walk test, thirty second sit to stand, and the linear analog scale of function in patients with head and neck cancer.

    PubMed

    Eden, Melissa M; Tompkins, James; Verheijde, Joseph L

    2018-03-01

    The purpose of this study was to establish the test-retest reliability of and relationships between various measures of physical function in a cohort of individuals in the early treatment stages for head and neck cancer (HNC). The Six-Minute Walk Test (6MWT), 10-Meter Walk Test (10MWT), 30-Second Sit to Stand (30STS), and Linear Analog Scale of Function (LASF) were administered to 42 participants with a diagnosis of HNC. Test-retest reliability and correlations between the measures are reported. The 6MWT, 10MWT, 30STS, and LASF demonstrate excellent test-retest reliability (ICC = 0.901-0.960). The 6MWT exhibits a moderate to good relationship with the 10MWT (r = 0.684, p < 0.001), whereas the relationship between the 30STS and the 6MWT (r = 0.407, p = 0.007) and 10MWT (r = 0.322, p = 0.038) is fair. The LASF does not correlate significantly with the 6MWT, 10MWT, or 30STS. The 6MWT, 10MWT, 30STS, and LASF are reliable measurement instruments for patients treated for HNC. The 6MWT, 10MWT, and 30STS are significantly correlated suggesting they may measure subconstructs of physical function. The LASF does not correlate significantly with the 6MWT, 10MWT and 30STS in this sample.

  12. Cross-cultural adaptation and validation of the Saudi Arabic version of the Knee Injury and Osteoarthritis Outcome Score (KOOS).

    PubMed

    Alfadhel, Saud A; Vennu, Vishal; Alnahdi, Ali H; Omar, Mohammed T; Alasmari, Saeed H; AlJafri, Zahra; Bindawas, Saad M

    2018-06-07

    The Knee Injury Osteoarthritis Outcome Score (KOOS) is a widely used joint-specific measure employed to evaluate pain, symptoms, activities of daily living, recreational activities, and quality of life in patients with knee osteoarthritis (OA). Although the original KOOS has been translated into many languages, a Saudi Arabic version is not available. This study aimed to culturally adapt and evaluate the psychometric properties of the Saudi Arabic version of the KOOS in patients with knee OA. The original KOOS was translated and adapted into Saudi Arabic version over six stages according to the guidelines suggested by Beaton and recommended by the American Association of Orthopedic Surgeons Outcome Committee. Patients diagnosed with knee OA (n = 136) were recruited to examine the psychometric properties, such as internal consistency that was tested using Cronbach's alpha, test-retest reliability that was analyzed using the intra-class correlation coefficient (ICC 2,1 ), and construct validity that examined by testing the correlations between the new version subscales, Form 36 Health Survey subscales, and the Visual Analog Scale, Spearman's correlation coefficient (r s ) was used to measure the correlations. A total of 122 (89.7%) of the 136 participants with knee OA completed the second re-test of new Saudi Arabic version. Excellent internal consistency (Cronbach's alpha = 0.87-0.92) was detected in the subscales of the adapted version, as well as excellent test-retest reliability (ICC 2,1  = 0.92-0.94). The pattern of correlation between the subscales of the Saudi Arabic version of the KOOS, SF-36 domains and the Visual Analog Scale for pain supported the construct validity of the adapted version. The Saudi Arabic version of the KOOS was well accepted and exhibited excellent reliability, internal consistency, and construct validity in Saudi patients with knee OA.

  13. A comprehensive statistical investigation of schlieren image velocimetry (SIV) using high-velocity helium jet

    NASA Astrophysics Data System (ADS)

    Biswas, Sayan; Qiao, Li

    2017-03-01

    A detailed statistical assessment of seedless velocity measurement using Schlieren Image Velocimetry (SIV) was explored using open source Robust Phase Correlation (RPC) algorithm. A well-known flow field, an axisymmetric turbulent helium jet, was analyzed near and intermediate region (0≤ x/d≤ 20) for two different Reynolds numbers, Re d = 11,000 and Re d = 22,000 using schlieren with horizontal knife-edge, schlieren with vertical knife-edge and shadowgraph technique, and the resulted velocity fields from SIV techniques were compared to traditional Particle Image Velocimetry (PIV) measurements. A novel, inexpensive, easy to setup two-camera SIV technique had been demonstrated to measure high-velocity turbulent jet, with jet exit velocities 304 m/s (Mach = 0.3) and 611 m/s (Mach = 0.6), respectively. Several image restoration and enhancement techniques were tested to improve signal to noise ratio (SNR) in schlieren and shadowgraph images. Processing and post-processing parameters for SIV techniques were examined in detail. A quantitative comparison between self-seeded SIV techniques and traditional PIV had been made using correlation statistics. While the resulted flow field from schlieren with horizontal knife-edge and shadowgraph showed excellent agreement with PIV measurements, schlieren with vertical knife-edge performed poorly. The performance of spatial cross-correlations at different jet locations using SIV techniques and PIV was evaluated. Turbulence quantities like turbulence intensity, mean velocity fields, Reynolds shear stress influenced spatial correlations and correlation plane SNR heavily. Several performance metrics such as primary peak ratio (PPR), peak to correlation energy (PCE), the probability distribution of signal and noise were used to compare capability and potential of different SIV techniques.

  14. Correlations Between Electrically Quantified Pain Degree, Subjectively Assessed Visual Analogue Scale, and the McGill Pain Questionnaire: A Pilot Study

    PubMed Central

    Kim, Junho; Lee, Kyung Soo; Kong, Sang Won; Kim, Taikon; Kim, Mi Jung; Park, Si-Bog

    2014-01-01

    Objective To evaluate the clinical utility of the electrically calculated quantitative pain degree (QPD) and to correlate it with subjective assessments of pain degree including a visual analogue scale (VAS) and the McGill Pain Questionnaire (MPQ). Methods We recruited 25 patients with low back pain. Of them, 21 patients suffered from low back pain for more than 3 months. The QPD was calculated using the PainVision (PV, PS-2100; Nipro Co., Osaka, Japan). We applied electrodes to the medial forearm of the subjects and the electrical stimulus was amplified sequentially. Minimum perceived current (MPC) and pain equivalent current (PEC) were defined as minimum electrical stimulation that could be sensed by the subject and electrical stimulation that could trigger actual pain itself. To eliminate individual differences, we defined QPD as the following: QPD=PEC-MPC/MPC. We scored pre-treatment QPD three times at admission and post-treatment QPD once at discharge. The VAS, MPQ, and QPD were evaluated and correlations between the scales were analyzed. Results Result showed significant test-retest reliability (ICC=0.967, p<0.001) and the correlation between QDP and MPQ was significant (at admission SRCC=0.619 and p=0.001; at discharge SRCC=0.628, p=0.001). However, the correlation between QPD and VAS was not significant (at admission SRCC=0.240, p=0.248; at discharge SRCC=0.289, p=0.161). Conclusion Numerical values measured with PV showed consistent results with repeated calculations. Electrically measured QPD showed an excellent correlation with MPQ but not with VAS. These results demonstrate that PV is a significantly reliable device for quantifying the intensity of low back pain. PMID:25379496

  15. Correlations Between Electrically Quantified Pain Degree, Subjectively Assessed Visual Analogue Scale, and the McGill Pain Questionnaire: A Pilot Study.

    PubMed

    Kim, Junho; Lee, Kyung Soo; Kong, Sang Won; Kim, Taikon; Kim, Mi Jung; Park, Si-Bog; Lee, Kyu Hoon

    2014-10-01

    To evaluate the clinical utility of the electrically calculated quantitative pain degree (QPD) and to correlate it with subjective assessments of pain degree including a visual analogue scale (VAS) and the McGill Pain Questionnaire (MPQ). We recruited 25 patients with low back pain. Of them, 21 patients suffered from low back pain for more than 3 months. The QPD was calculated using the PainVision (PV, PS-2100; Nipro Co., Osaka, Japan). We applied electrodes to the medial forearm of the subjects and the electrical stimulus was amplified sequentially. Minimum perceived current (MPC) and pain equivalent current (PEC) were defined as minimum electrical stimulation that could be sensed by the subject and electrical stimulation that could trigger actual pain itself. To eliminate individual differences, we defined QPD as the following: QPD=PEC-MPC/MPC. We scored pre-treatment QPD three times at admission and post-treatment QPD once at discharge. The VAS, MPQ, and QPD were evaluated and correlations between the scales were analyzed. Result showed significant test-retest reliability (ICC=0.967, p<0.001) and the correlation between QDP and MPQ was significant (at admission SRCC=0.619 and p=0.001; at discharge SRCC=0.628, p=0.001). However, the correlation between QPD and VAS was not significant (at admission SRCC=0.240, p=0.248; at discharge SRCC=0.289, p=0.161). Numerical values measured with PV showed consistent results with repeated calculations. Electrically measured QPD showed an excellent correlation with MPQ but not with VAS. These results demonstrate that PV is a significantly reliable device for quantifying the intensity of low back pain.

  16. Confirmatory factor analysis using Microsoft Excel.

    PubMed

    Miles, Jeremy N V

    2005-11-01

    This article presents a method for using Microsoft (MS) Excel for confirmatory factor analysis (CFA). CFA is often seen as an impenetrable technique, and thus, when it is taught, there is frequently little explanation of the mechanisms or underlying calculations. The aim of this article is to demonstrate that this is not the case; it is relatively straightforward to produce a spreadsheet in MS Excel that can carry out simple CFA. It is possible, with few or no programming skills, to effectively program a CFA analysis and, thus, to gain insight into the workings of the procedure.

  17. Synchrotron x-ray scattering study of charge-density-wave order in HgBa2CuO4 +δ

    NASA Astrophysics Data System (ADS)

    Tabis, W.; Yu, B.; Bialo, I.; Bluschke, M.; Kolodziej, T.; Kozlowski, A.; Blackburn, E.; Sen, K.; Forgan, E. M.; Zimmermann, M. v.; Tang, Y.; Weschke, E.; Vignolle, B.; Hepting, M.; Gretarsson, H.; Sutarto, R.; He, F.; Le Tacon, M.; Barišić, N.; Yu, G.; Greven, M.

    2017-10-01

    We present a detailed synchrotron x-ray scattering study of the charge-density-wave (CDW) order in simple tetragonal HgBa2CuO4 +δ (Hg1201). Resonant soft x-ray scattering measurements reveal that short-range order appears at a temperature that is distinctly lower than the pseudogap temperature and in excellent agreement with a prior transient reflectivity result. Despite considerable structural differences between Hg1201 and YBa2Cu3O6 +δ , the CDW correlations exhibit similar doping dependencies, and we demonstrate a universal relationship between the CDW wave vector and the size of the reconstructed Fermi pocket observed in quantum oscillation experiments. The CDW correlations in Hg1201 vanish already below optimal doping, once the correlation length is comparable to the CDW modulation period, and they appear to be limited by the disorder potential from unit cells hosting two interstitial oxygen atoms. A complementary hard x-ray diffraction measurement, performed on an underdoped Hg1201 sample in magnetic fields along the crystallographic c axis of up to 16 T, provides information on the form factor of the CDW order. As expected from the single-CuO2-layer structure of Hg1201, the CDW correlations vanish at half-integer values of L and appear to be peaked at integer L . We conclude that the atomic displacements associated with the short-range CDW order are mainly planar, within the CuO2 layers.

  18. Solving L-L Extraction Problems with Excel Spreadsheet

    ERIC Educational Resources Information Center

    Teppaitoon, Wittaya

    2016-01-01

    This work aims to demonstrate the use of Excel spreadsheets for solving L-L extraction problems. The key to solving the problems successfully is to be able to determine a tie line on the ternary diagram where the calculation must be carried out. This enables the reader to analyze the extraction process starting with a simple operation, the…

  19. EXCELS!--Evaluating Integrated Language Arts and Social Studies. The Jamestown Integrated Performance Assessment Unit.

    ERIC Educational Resources Information Center

    Fenton, Ray; Straugh, Tom; Stofflet, Fred; Shaffer, Frank

    The EXCELS! Project of the Anchorage School District (Alaska) was initiated in 1994 through a grant from the U.S. Department of Education to demonstrate the development of a kindergarten through sixth grade instructional program reflecting state and national standards in History, Civics, Geography, and English. More than 1,200 Anchorage teachers…

  20. Improving Graduate Students' Graphing Skills of Multiple Baseline Designs with Microsoft[R] Excel 2007

    ERIC Educational Resources Information Center

    Lo, Ya-yu; Starling, A. Leyf Peirce

    2009-01-01

    This study examined the effects of a graphing task analysis using the Microsoft[R] Office Excel 2007 program on the single-subject multiple baseline graphing skills of three university graduate students. Using a multiple probe across participants design, the study demonstrated a functional relationship between the number of correct graphing…

  1. SnO2@TiO2 double-shell nanotubes for a lithium ion battery anode with excellent high rate cyclability.

    PubMed

    Jeun, Jeong-Hoon; Park, Kyu-Young; Kim, Dai-Hong; Kim, Won-Sik; Kim, Hong-Chan; Lee, Byoung-Sun; Kim, Honggu; Yu, Woong-Ryeol; Kang, Kisuk; Hong, Seong-Hyeon

    2013-09-21

    SnO2@TiO2 double-shell nanotubes have been facilely synthesized by atomic layer deposition (ALD) using electrospun PAN nanofibers as templates. The double-shell nanotubes exhibited excellent high rate cyclability for lithium ion batteries. The retention of hollow structures during cycling was demonstrated.

  2. Clinical study of tooth shade lightening from dentist-supervised, patient-applied treatment with two 10% carbamide peroxide gels.

    PubMed

    Cibirka, R M; Myers, M; Downey, M C; Nelson, S K; Browning, W D; Hawkins, I K; Dickinson, G L

    1999-01-01

    Prescribed, patient-applied tooth lightening agents, or nightguard vital bleaching, typically utilizes a 10% carbamide peroxide agent applied during nocturnal hours. The purpose of this randomized double-blind study was to compare the amount of tooth color change in two groups of subjects using dentist-supervised, patient-applied 10% carbamide peroxide gel. One group used Opalescence (Ultradent Products Inc., South Jordan, Utah) and the other NiteWhite Excel (Discus Dental, Inc., Los Angeles, California). Evaluation of tooth color for the six maxillary anterior teeth was done using a Vita shade guide at baseline, 1, 2, and 4 weeks. Subjects were instructed to apply the gel nocturnally using a custom-made soft tray 8 hours per day for 2 weeks. The 16 tabs of the shade guide were ranked according to value from darkest to lightest. The number (1-16) that correlated to the shade tab selected as the match for each tooth was the outcome variable. A Kruskal-Wallis one way analysis of variance on ranks was used. The test revealed no statistically significant difference between Opalescence and NiteWhite Excel for lightening the teeth (p = .807). The color change was still significant after 2 weeks without further bleaching activity. The baseline evaluation of the maxillary incisors and canines for all subjects, regardless of group, demonstrated a significant shade difference, with the canines being darker. This difference was not seen after 2 weeks of active bleaching or at the 4-week evaluation. In this study comparing bleaching products, patients using Opalescence and NiteWhite Excel experienced a significant change in the color of their teeth relative to baseline values after 2 weeks of active treatment.

  3. Green Synthesis of Bifunctional Fluorescent Carbon Dots from Garlic for Cellular Imaging and Free Radical Scavenging.

    PubMed

    Zhao, Shaojing; Lan, Minhuan; Zhu, Xiaoyue; Xue, Hongtao; Ng, Tsz-Wai; Meng, Xiangmin; Lee, Chun-Sing; Wang, Pengfei; Zhang, Wenjun

    2015-08-12

    Nitrogen and sulfur codoped carbon dots (CDs) were prepared from garlic by a hydrothermal method. The as-prepared CDs possess good water dispersibility, strong blue fluorescence emission with a fluorescent quantum yield of 17.5%, and excellent photo and pH stabilities. It is also demonstrated that the fluorescence of CDs are resistant to the interference of metal ions, biomolecules, and high ionic strength environments. Combining with low cytotoxicity properties, CDs could be used as an excellent fluorescent probe for cellular multicolor imaging. Moreover, the CDs were also demonstrated to exhibit favorable radical scavenging activity.

  4. Reliability of the ECHOWS Tool for Assessment of Patient Interviewing Skills.

    PubMed

    Boissonnault, Jill S; Evans, Kerrie; Tuttle, Neil; Hetzel, Scott J; Boissonnault, William G

    2016-04-01

    History taking is an important component of patient/client management. Assessment of student history-taking competency can be achieved via a standardized tool. The ECHOWS tool has been shown to be valid with modest intrarater reliability in a previous study but did not demonstrate sufficient power to definitively prove its stability. The purposes of this study were: (1) to assess the reliability of the ECHOWS tool for student assessment of patient interviewing skills and (2) to determine whether the tool discerns between novice and experienced skill levels. A reliability and construct validity assessment was conducted. Three faculty members from the United States and Australia scored videotaped histories from standardized patients taken by students and experienced clinicians from each of these countries. The tapes were scored twice, 3 to 6 weeks apart. Reliability was assessed using interclass correlation coefficients (ICCs) and repeated measures. Analysis of variance models assessed the ability of the tool to discern between novice and experienced skill levels. The ECHOWS tool showed excellent intrarater reliability (ICC [3,1]=.74-.89) and good interrater reliability (ICC [2,1]=.55) as a whole. The summary of performance (S) section showed poor interrater reliability (ICC [2,1]=.27). There was no statistical difference in performance on the tool between novice and experienced clinicians. A possible ceiling effect may occur when standardized patients are not coached to provide complex and obtuse responses to interviewer questions. Variation in familiarity with the ECHOWS tool and in use of the online training may have influenced scoring of the S section. The ECHOWS tool demonstrates excellent intrarater reliability and moderate interrater reliability. Sufficient training with the tool prior to student assessment is recommended. The S section must evolve in order to provide a more discerning measure of interviewing skills. © 2016 American Physical Therapy Association.

  5. The reliability of the Associate Platinum digital foot scanner in measuring previously developed footprint characteristics: a technical note.

    PubMed

    Papuga, M Owen; Burke, Jeanmarie R

    2011-02-01

    An ink pad and paper, pressure-sensitive platforms, and photography have previously been used to collect footprint data used in clinical assessment. Digital scanners have been widely used more recently to collect such data. The purpose of this study was to evaluate the intra- and interrater reliability of a flatbed digital image scanning technology to capture footprint data. This study used a repeated-measures design on 32 (16 male 16 female) healthy subjects. The following measured indices of footprint were recorded from 2-dimensional images of the plantar surface of the foot recorded with an Associate Platinum (Foot Levelers Inc, Roanoke, VA) digital foot scanner: Staheli index, Chippaux-Smirak index, arch angle, and arch index. Intraclass correlation coefficient (ICC) values were calculated to evaluate intrarater, interday, and interclinician reliability. The ICC values for intrarater reliability were greater than or equal to .817, indicating an excellent level of reproducibility in assessing the collected images. Analyses of variance revealed that there were no significant differences between raters for each index (P > .05). The ICC values also indicated excellent reliability (.881-.971) between days and clinicians in all but one of the indices of footprint, arch angle (.689), with good reliability between clinicians. The full-factorial analysis of variance model did not reveal any interaction effects (P > .05), which indicated that indices of footprint were not changing across days and clinicians. Scanning technology used in this study demonstrated good intra- and interrater reliability measurements of footprint indices, as demonstrated by high ICC values. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  6. Ego-Dissolution and Psychedelics: Validation of the Ego-Dissolution Inventory (EDI).

    PubMed

    Nour, Matthew M; Evans, Lisa; Nutt, David; Carhart-Harris, Robin L

    2016-01-01

    The experience of a compromised sense of "self", termed ego-dissolution, is a key feature of the psychedelic experience. This study aimed to validate the Ego-Dissolution Inventory (EDI), a new 8-item self-report scale designed to measure ego-dissolution. Additionally, we aimed to investigate the specificity of the relationship between psychedelics and ego-dissolution. Sixteen items relating to altered ego-consciousness were included in an internet questionnaire; eight relating to the experience of ego-dissolution (comprising the EDI), and eight relating to the antithetical experience of increased self-assuredness, termed ego-inflation. Items were rated using a visual analog scale. Participants answered the questionnaire for experiences with classical psychedelic drugs, cocaine and/or alcohol. They also answered the seven questions from the Mystical Experiences Questionnaire (MEQ) relating to the experience of unity with one's surroundings. Six hundred and ninety-one participants completed the questionnaire, providing data for 1828 drug experiences (1043 psychedelics, 377 cocaine, 408 alcohol). Exploratory factor analysis demonstrated that the eight EDI items loaded exclusively onto a single common factor, which was orthogonal to a second factor comprised of the items relating to ego-inflation (rho = -0.110), demonstrating discriminant validity. The EDI correlated strongly with the MEQ-derived measure of unitive experience (rho = 0.735), demonstrating convergent validity. EDI internal consistency was excellent (Cronbach's alpha 0.93). Three analyses confirmed the specificity of ego-dissolution for experiences occasioned by psychedelic drugs. Firstly, EDI score correlated with drug-dose for psychedelic drugs (rho = 0.371), but not for cocaine (rho = 0.115) or alcohol (rho = -0.055). Secondly, the linear regression line relating the subjective intensity of the experience to ego-dissolution was significantly steeper for psychedelics (unstandardized regression coefficient = 0.701) compared with cocaine (0.135) or alcohol (0.144). Ego-inflation, by contrast, was specifically associated with cocaine experiences. Finally, a binary Support Vector Machine classifier identified experiences occasioned by psychedelic drugs vs. cocaine or alcohol with over 85% accuracy using ratings of ego-dissolution and ego-inflation alone. Our results demonstrate the psychometric structure, internal consistency and construct validity of the EDI. Moreover, we demonstrate the close relationship between ego-dissolution and the psychedelic experience. The EDI will facilitate the study of the neuronal correlates of ego-dissolution, which is relevant for psychedelic-assisted psychotherapy and our understanding of psychosis.

  7. Strong correlation effects on surfaces of topological insulators via holography

    NASA Astrophysics Data System (ADS)

    Seo, Yunseok; Song, Geunho; Sin, Sang-Jin

    2017-07-01

    We investigate the effects of strong correlation on the surface state of a topological insulator (TI). We argue that electrons in the regime of crossover from weak antilocalization to weak localization are strongly correlated, and calculate the magnetotransport coefficients of TIs using the gauge-gravity principle. Then, we examine the magnetoconductivity (MC) formula and find excellent agreement with the data of chrome-doped Bi2Te3 in the crossover regime. We also find that the cusplike peak in MC at low doping is absent, which is natural since quasiparticles disappear due to the strong correlation.

  8. Using Correlational and Prediction Data to Enhance Student Achievement in K-12 Schools: A Practical Application for School Counselors

    ERIC Educational Resources Information Center

    Ware, William B.; Galassi, John P.

    2006-01-01

    Correlational data and regression analysis provide the school counselor with a method to describe growth in achievement test scores from elementary to high school. Using Microsoft Excel, this article shows the reader in a step-by-step manner how to describe this growth pattern and how to evaluate interventions that attempt to enhance achievement…

  9. Mechanical properties of stemwood and limbwood of seed orchard loblolly pine

    Treesearch

    R. H. McAlister; H. R. Powers; W. D. Pepper

    2000-01-01

    Tests were made on micro-bending specimens prepared from stem and limb sections of 11 rust-resistant loblolly pines from a central Georgia seed orchard. A fair correlation (|r| = 0.45 to 0.55) emerged between the stemwood and limbwood modulus of elasticity (MOE) and stemwood and limbwood modulus ofrupture (MOR) values. An excellent correlation (|r| = 0.8 to 0.9)...

  10. Prediction of Liquid Slosh Damping Using a High Resolution CFD Tool

    NASA Technical Reports Server (NTRS)

    Yang, H. Q.; Purandare, Ravi; Peugeot, John; West, Jeff

    2012-01-01

    Propellant slosh is a potential source of disturbance critical to the stability of space vehicles. The slosh dynamics are typically represented by a mechanical model of a spring mass damper. This mechanical model is then included in the equation of motion of the entire vehicle for Guidance, Navigation and Control analysis. Our previous effort has demonstrated the soundness of a CFD approach in modeling the detailed fluid dynamics of tank slosh and the excellent accuracy in extracting mechanical properties (slosh natural frequency, slosh mass, and slosh mass center coordinates). For a practical partially-filled smooth wall propellant tank with a diameter of 1 meter, the damping ratio is as low as 0.0005 (or 0.05%). To accurately predict this very low damping value is a challenge for any CFD tool, as one must resolve a thin boundary layer near the wall and must minimize numerical damping. This work extends our previous effort to extract this challenging parameter from first principles: slosh damping for smooth wall and for ring baffle. First the experimental data correlated into the industry standard for smooth wall were used as the baseline validation. It is demonstrated that with proper grid resolution, CFD can indeed accurately predict low damping values from smooth walls for different tank sizes. The damping due to ring baffles at different depths from the free surface and for different sizes of tank was then simulated, and fairly good agreement with experimental correlation was observed. The study demonstrates that CFD technology can be applied to the design of future propellant tanks with complex configurations and with smooth walls or multiple baffles, where previous experimental data is not available.

  11. Psychometric evaluation of the Chinese version of the Child Health Utility 9D (CHU9D-CHN): a school-based study in China.

    PubMed

    Yang, Peirong; Chen, Gang; Wang, Peng; Zhang, Kejian; Deng, Feng; Yang, Haifeng; Zhuang, Guihua

    2018-05-05

    The Child Health Utility 9D (CHU9D), a new generic preference-based health-related quality of life (HRQoL) instrument, was developed specifically for the application in cost-effectiveness analyses of treatments and interventions for children and adolescents. The main objective of this study was to examine the psychometric property of the Chinese version of CHU9D (CHU9D-CHN) in a large school-based sample in China. Data were collected using a multi-stage sampling method from third-to-ninth-grade students in Shaanxi Province, China. Participants self-completed a hard-copy questionnaire including the CHU9D-CHN instrument, the Pediatric Quality of Life Inventory™ 4.0 Generic Core Scales (PedsQL), information on socio-demographic characteristics and self-reported health status. The psychometric properties of the CHU9D-CHN, including the internal consistency, 2-week test-retest reliability, convergent and known-groups validity were studied. A total of 1912 students participated in the survey. The CHU9D-CHN internal consistency and test-retest reliability were good to excellent with a Cronbach's alpha of 0.77 and an intra-class correlation coefficient of 0.65, respectively. The CHU9D utility scores moderately correlated with the PedsQL total scores (r = .57, P < .001), demonstrating good convergent validity. Difference of the CHU9D utility scores among the different participants with levels of self-reported general health, health services utilisation and left-behind status demonstrated good construct validity. The findings demonstrated adequate psychometric performance for the CHU9D-CHN. The CHU9D-CHN was a satisfactory, reliable and valid instrument to measure and value HRQoL for children and adolescents in China.

  12. Initial formal toxicity evaluation of APC-2, a novel fluorescent tracer agent for real-time measurement of glomerular filtration rate in preparation for a first-in-man clinical trial

    NASA Astrophysics Data System (ADS)

    Bugaj, Joseph E.; Dorshow, Richard B.

    2014-03-01

    The fluorescent tracer agent 2,5-bis[N-(1-carboxy-2-hydroxy)]carbamoyl-3,6-diaminopyrazine, designated APC-2, has been developed with properties and attributes necessary for use as a direct measure of glomerular filtration rate (GFR). Comparison to known standard exogenous GFR agents in animal models has demonstrated an excellent correlation. A clinical trial to demonstrate this same correlation in humans is in preparation. A battery of formal toxicity tests necessary for regulatory clearance to proceed with a clinical trial has been recently completed on this new fluorescent tracer agent. These include single dose toxicity studies in rats and dogs to determine overall toxicity and toxicokinetics of the compound. Blood compatibility, mutation assay, chromosomal aberration assay, and several other assays were also completed. Toxicity assessments were based on mortality, clinical signs, body weight, food consumption and anatomical pathology. Blood samples were collected to assess pharmacokinetic parameters including half-life, area under the curve, and clearance. Urine samples were collected to assess distribution. Doses of up to 200-300 times the estimated human dose were administered. No test-article related effects were noted on body weight, food consumption, ophthalmic observations and no abnormal pathology was seen in either macroscopic or microscopic evaluations of any organs or tissues. All animals survived to scheduled sacrifice. Transient discoloration of skin and urine was noted at the higher dose levels in both species as expected from a highly fluorescent compound and was not considered pathological. Thus initial toxicology studies of this new fluorescent tracer agent APC-2 have resulted in no demonstrable pathological test article concerns.

  13. Dynamics of hemispheric dominance for language assessed by magnetoencephalographic imaging.

    PubMed

    Findlay, Anne M; Ambrose, Josiah B; Cahn-Weiner, Deborah A; Houde, John F; Honma, Susanne; Hinkley, Leighton B N; Berger, Mitchel S; Nagarajan, Srikantan S; Kirsch, Heidi E

    2012-05-01

    The goal of the current study was to examine the dynamics of language lateralization using magnetoencephalographic (MEG) imaging, to determine the sensitivity and specificity of MEG imaging, and to determine whether MEG imaging can become a viable alternative to the intracarotid amobarbital procedure (IAP), the current gold standard for preoperative language lateralization in neurosurgical candidates. MEG was recorded during an auditory verb generation task and imaging analysis of oscillatory activity was initially performed in 21 subjects with epilepsy, brain tumor, or arteriovenous malformation who had undergone IAP and MEG. Time windows and brain regions of interest that best discriminated between IAP-determined left or right dominance for language were identified. Parameters derived in the retrospective analysis were applied to a prospective cohort of 14 patients and healthy controls. Power decreases in the beta frequency band were consistently observed following auditory stimulation in inferior frontal, superior temporal, and parietal cortices; similar power decreases were also seen in inferior frontal cortex prior to and during overt verb generation. Language lateralization was clearly observed to be a dynamic process that is bilateral for several hundred milliseconds during periods of auditory perception and overt speech production. Correlation with the IAP was seen in 13 of 14 (93%) prospective patients, with the test demonstrating a sensitivity of 100% and specificity of 92%. Our results demonstrate excellent correlation between MEG imaging findings and the IAP for language lateralization, and provide new insights into the spatiotemporal dynamics of cortical speech processing. Copyright © 2012 American Neurological Association.

  14. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry--BREALD-30.

    PubMed

    Junkes, Monica C; Fraiz, Fabian C; Sardenberg, Fernanda; Lee, Jessica Y; Paiva, Saul M; Ferreira, Fernanda M

    2015-01-01

    The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. The BREALD-30 demonstrated good internal reliability. Cronbach's alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent's perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent's perception regarding his/her child's oral health remained significant in the multivariate analysis. The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil.

  15. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry – BREALD-30

    PubMed Central

    Junkes, Monica C.; Fraiz, Fabian C.; Sardenberg, Fernanda; Lee, Jessica Y.; Paiva, Saul M.; Ferreira, Fernanda M.

    2015-01-01

    Objective The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. Methods After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. Results The BREALD-30 demonstrated good internal reliability. Cronbach’s alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent’s perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent’s perception regarding his/her child's oral health remained significant in the multivariate analysis. Conclusion The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil. PMID:26158724

  16. Speckle correlation resolution enhancement of wide-field fluorescence imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Yilmaz, Hasan

    2016-03-01

    Structured illumination enables high-resolution fluorescence imaging of nanostructures [1]. We demonstrate a new high-resolution fluorescence imaging method that uses a scattering layer with a high-index substrate as a solid immersion lens [2]. Random scattering of coherent light enables a speckle pattern with a very fine structure that illuminates the fluorescent nanospheres on the back surface of the high-index substrate. The speckle pattern is raster-scanned over the fluorescent nanospheres using a speckle correlation effect known as the optical memory effect. A series of standard-resolution fluorescence images per each speckle pattern displacement are recorded by an electron-multiplying CCD camera using a commercial microscope objective. We have developed a new phase-retrieval algorithm to reconstruct a high-resolution, wide-field image from several standard-resolution wide-field images. We have introduced phase information of Fourier components of standard-resolution images as a new constraint in our algorithm which discards ambiguities therefore ensures convergence to a unique solution. We demonstrate two-dimensional fluorescence images of a collection of nanospheres with a deconvolved Abbe resolution of 116 nm and a field of view of 10 µm × 10 µm. Our method is robust against optical aberrations and stage drifts, therefore excellent for imaging nanostructures under ambient conditions. [1] M. G. L. Gustafsson, J. Microsc. 198, 82-87 (2000). [2] H. Yilmaz, E. G. van Putten, J. Bertolotti, A. Lagendijk, W. L. Vos, and A. P. Mosk, Optica 2, 424-429 (2015).

  17. Evaluation of the psychometric properties of the Pediatric Parenting Stress Inventory (PPSI).

    PubMed

    Devine, Katie A; Heckler, Charles E; Katz, Ernest R; Fairclough, Diane L; Phipps, Sean; Sherman-Bien, Sandra; Dolgin, Michael J; Noll, Robert B; Askins, Martha A; Butler, Robert W; Sahler, Olle Jane Z

    2014-02-01

    This work evaluated the psychometric properties of the Pediatric Parenting Stress Inventory (PPSI), a new measure of problems and distress experienced by parents of children with chronic illnesses. This secondary data analysis used baseline data from 1 sample of English-, Spanish-, and Hebrew-speaking mothers of children recently diagnosed with cancer (n = 449) and 1 sample of English- and Spanish-speaking mothers of children recently diagnosed with cancer (n = 399) who participated in 2 problem-solving skills training interventions. The PPSI was administered at baseline with other measures of maternal distress. Factor structure was evaluated using exploratory factor analysis (EFA) on the first sample and confirmatory factor analysis (CFA) on both samples. Internal consistency was evaluated using Cronbach's alpha. Construct validity was assessed via Spearman correlations with measures of maternal distress. EFA resulted in a stable four-factor solution with 35 items. CFA indicated that the four-factor solution demonstrated reasonable fit in both samples. Internal consistency of the subscales and full scale was adequate to excellent. Construct validity was supported by moderate to strong correlations with measures of maternal distress, depression, and posttraumatic stress symptoms. The PPSI demonstrated good psychometric properties in assessing current problems and distress experienced by mothers of children newly diagnosed with cancer. This tool may be used to identify individualized targets for intervention in families of children with cancer. Future studies could evaluate the utility and psychometrics of the PPSI with other pediatric populations. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  18. Validity and Reliability of the 8-Item Work Limitations Questionnaire.

    PubMed

    Walker, Timothy J; Tullar, Jessica M; Diamond, Pamela M; Kohl, Harold W; Amick, Benjamin C

    2017-12-01

    Purpose To evaluate factorial validity, scale reliability, test-retest reliability, convergent validity, and discriminant validity of the 8-item Work Limitations Questionnaire (WLQ) among employees from a public university system. Methods A secondary analysis using de-identified data from employees who completed an annual Health Assessment between the years 2009-2015 tested research aims. Confirmatory factor analysis (CFA) (n = 10,165) tested the latent structure of the 8-item WLQ. Scale reliability was determined using a CFA-based approach while test-retest reliability was determined using the intraclass correlation coefficient. Convergent/discriminant validity was tested by evaluating relations between the 8-item WLQ with health/performance variables for convergent validity (health-related work performance, number of chronic conditions, and general health) and demographic variables for discriminant validity (gender and institution type). Results A 1-factor model with three correlated residuals demonstrated excellent model fit (CFI = 0.99, TLI = 0.99, RMSEA = 0.03, and SRMR = 0.01). The scale reliability was acceptable (0.69, 95% CI 0.68-0.70) and the test-retest reliability was very good (ICC = 0.78). Low-to-moderate associations were observed between the 8-item WLQ and the health/performance variables while weak associations were observed between the demographic variables. Conclusions The 8-item WLQ demonstrated sufficient reliability and validity among employees from a public university system. Results suggest the 8-item WLQ is a usable alternative for studies when the more comprehensive 25-item WLQ is not available.

  19. The reliability and criterion validity of 2D video assessment of single leg squat and hop landing.

    PubMed

    Herrington, Lee; Alenezi, Faisal; Alzhrani, Msaad; Alrayani, Hasan; Jones, Richard

    2017-06-01

    The objective was to assess the intra-tester, within and between day reliability of measurement of hip adduction (HADD) and frontal plane projection angles (FPPA) during single leg squat (SLS) and single leg landing (SLL) using 2D video and the validity of these measurements against those found during 3D motion capture. 15 healthy subjects had their SLS and SLL assessed using 3D motion capture and video analysis. Inter-tester reliability for both SLS and SLL when measuring FPPA and HADD show excellent correlations (ICC 2,1 0.97-0.99). Within and between day assessment of SLS and SLL showed good to excellent correlations for both variables (ICC 3,1 0.72-91). 2D FPPA measures were found to have good correlation with knee abduction angle in 3-D (r=0.79, p=0.008) during SLS, and also to knee abduction moment (r=0.65, p=0.009). 2D HADD showed very good correlation with 3D HADD during SLS (r=0.81, p=0.001), and a good correlation during SLL (r=0.62, p=0.013). All other associations were weak (r<0.4). This study suggests that 2D video kinematics have a reasonable association to what is being measured with 3D motion capture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. First experimental demonstration of self-synchronous phase locking of an optical array

    NASA Astrophysics Data System (ADS)

    Shay, T. M.; Benham, Vincent; Baker, J. T.; Ward, Benjamin; Sanchez, Anthony D.; Culpepper, Mark A.; Pilkington, D.; Spring, Justin; Nelson, Douglas J.; Lu, Chunte A.

    2006-12-01

    A novel, highly accurate, all electronic technique for phase locking arrays of optical fibers is demonstrated. We report the first demonstration of the only electronic phase locking technique that doesn’t require a reference beam. The measured phase error is λ/20. Excellent phase locking has been demonstrated for fiber amplifier arrays.

  1. Using Group Performances to Demonstrate Concepts in Large Biology Classes

    ERIC Educational Resources Information Center

    Wellnitz, Todd

    2006-01-01

    While a voluminous lecture hall can present obstacles to effective teaching and learning, large classrooms containing more than 100 students also present teaching opportunities. The lecture hall offers an excellent arena for demonstrating concepts that lend themselves to demonstrations and something this author refers to as "group performances."…

  2. Equity and Excellence: The Emergence, Consolidation and Internalization of Education Development at the University of Natal

    ERIC Educational Resources Information Center

    Odendaal, Marie; Deacon, Roger

    2009-01-01

    Education development in South Africa emerged during the transition from apartheid to democracy, in a context especially marked by political and financial pressures. This case study of the University of Natal (now the University of KwaZulu-Natal) demonstrates how a strategy combining equity with excellence aimed to facilitate increased access to…

  3. Gervais High School: 100% Committed to Excellence

    ERIC Educational Resources Information Center

    Principal Leadership, 2013

    2013-01-01

    Gervais High School--with a senior class of 80 and a total enrollment of 337--may be small in size compared to its neighbors, but it has demonstrated over the last four years the ability to think big in pursuit of excellence. A decade ago, Gervais had a well-earned reputation in Oregon's Willamette Valley as a drug-ridden, gang-infested school…

  4. Translation, Cross-cultural Adaptation and Validation of the Farsi Version of NIH Task Force's Recommended Multidimensional Minimal Dataset for Research on Chronic Low Back Pain.

    PubMed

    Noormohammadpour, Pardis; Tavana, Bahareh; Mansournia, Mohammad Ali; Zeinalizadeh, Mehdi; Mirzashahi, Babak; Rostami, Mohsen; Kordi, Ramin

    2018-05-01

    Translation and cultural adaptation of the National Institutes of Health (NIH) Task Force's minimal dataset. The purpose of this study was to evaluate validity and reliability of the Farsi version of NIH Task Force's recommended multidimensional minimal dataset for research on chronic low back pain (CLBP). Considering the high treatment cost of CLBP and its increasing prevalence, NIH Pain Consortium developed research standards (including recommendations for definitions, a minimum dataset, and outcomes' report) for studies regarding CLBP. Application of these recommendations could standardize research and improve comparability of different studies in CLBP. This study has three phases: translation of dataset into Farsi and its cultural adaptation, assessment of pre-final version of dataset's comprehensibility via a pilot study, and investigation of the reliability and validity of final version of translated dataset. Subjects were 250 patients with CLBP. Test-retest reliability, content validity, and convergent validity (correlations among different dimensions of dataset and Farsi versions of Oswestry Disability Index, Roland Morris Disability Questionnaire, Fear-Avoidance Belief Questionnaire, and Beck Depression Inventory-II) were assessed. The Farsi version demonstrated good/excellent convergent validity (the correlation coefficient between impact dimension and ODI was r = 0.75 [P < 0.001], between impact dimension and Roland-Morris Disability Questionnaire was r = 0.80 [P < 0.001], and between psychological dimension and BDI was r = 0.62 [P < 0.001]). The test-retest reliability was also strong (intraclass correlation coefficient value ranged between 0.70 and 0.95) and the internal consistency was good/excellent (Chronbach's alpha coefficients' value for two main dimensions including impact dimension and psychological dimension were 0.91 and 0.82 [P < 0.001], respectively). In addition, its face validity and content validity were acceptable. The Farsi version of minimal dataset for research on CLBP is a reliable and valid instrument for data gathering in patients with CLBP. This minimum dataset can be a step toward standardization of research regarding CLBP. 3.

  5. Development and validation of a primary sclerosing cholangitis-specific patient-reported outcomes instrument: The PSC PRO.

    PubMed

    Younossi, Zobair M; Afendy, Arian; Stepanova, Maria; Racila, Andrei; Nader, Fatema; Gomel, Rachel; Safer, Ricky; Lenderking, William R; Skalicky, Anne; Kleinman, Leah; Myers, Robert P; Subramanian, G Mani; McHutchison, John G; Levy, Cynthia; Bowlus, Christopher L; Kowdley, Kris; Muir, Andrew J

    2017-11-20

    Primary sclerosing cholangitis (PSC) is a chronic liver disease associated with inflammation and biliary fibrosis that leads to cholangitis, cirrhosis, and impaired quality of life. Our objective was to develop and validate a PSC-specific patient-reported outcome (PRO) instrument. We developed a 42-item PSC PRO instrument that contains two modules (Symptoms and Impact of Symptoms) and conducted an external validation. Reliability and validity were evaluated using clinical data and a battery of other validated instruments. Test-retest reliability was assessed in a subgroup of patients who repeated the PSC PRO after the first administration. One hundred two PSC subjects (44 ± 13 years; 32% male, 74% employed, 39% with cirrhosis, 14% with a history of decompensated cirrhosis, 38% history of depression, and 68% with inflammatory bowel disease [IBD]) completed PSC PRO and other PRO instruments (Short Form 36 V2 [SF-36], Chronic Liver Disease Questionnaire [CLDQ], Primary Biliary Cholangitis - 40 [PBC-40], and five dimensions [5-D Itch]). PSC PRO demonstrated excellent internal consistency (Cronbach alphas, 0.84-0.94) and discriminant validity (41 of 42 items had the highest correlations with their own domains). There were good correlations between PSC PRO domains and relevant domains of SF-36, CLDQ, and PBC-40 (R = 0.69-0.90; all P < 0.0001), but lower (R = 0.31-0.60; P < 0.001) with 5-D Itch. Construct validity showed that PSC PRO can differentiate patients according to the presence and severity of cirrhosis and history of depression (P < 0.05), but not by IBD (P > 0.05). Test-retest reliability was assessed in 53 subjects who repeated PSC PRO within a median (interquartile range) of 37 (27-47) days. There was excellent reliability for most domains with intraclass correlations (0.71-0.88; all P < 0.001). PSC PRO is a self-administered disease-specific instrument developed according to U.S. Food and Drug Administration guidelines. This preliminary validation study suggests good psychometric properties. Further validation of the instrument in a larger and more diverse sample of PSC patients is needed. (Hepatology 2017). © 2017 by the American Association for the Study of Liver Diseases.

  6. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: V. Predictive absorbability models.

    PubMed

    Langenbucher, Frieder

    2007-08-01

    This paper discusses Excel applications related to the prediction of drug absorbability from physicochemical constants. PHDISSOC provides a generalized model for pH profiles of electrolytic dissociation, water solubility, and partition coefficient. SKMODEL predicts drug absorbability, based on a log-log plot of water solubility and O/W partitioning; augmented by additional features such as electrolytic dissociation, melting point, and the dose administered. GIABS presents a mechanistic model of g.i. drug absorption. BIODATCO presents a database compiling relevant drug data to be used for quantitative predictions.

  7. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: IV. Generalized matrix analysis of linear compartment systems.

    PubMed

    Langenbucher, Frieder

    2005-01-01

    A linear system comprising n compartments is completely defined by the rate constants between any of the compartments and the initial condition in which compartment(s) the drug is present at the beginning. The generalized solution is the time profiles of drug amount in each compartment, described by polyexponential equations. Based on standard matrix operations, an Excel worksheet computes the rate constants and the coefficients, finally the full time profiles for a specified range of time values.

  8. Real-time 3D transesophageal echocardiography for the evaluation of rheumatic mitral stenosis.

    PubMed

    Schlosshan, Dominik; Aggarwal, Gunjan; Mathur, Gita; Allan, Roger; Cranney, Greg

    2011-06-01

    The aims of this study were: 1) to assess the feasibility and reliability of performing mitral valve area (MVA) measurements in patients with rheumatic mitral valve stenosis (RhMS) using real-time 3-dimensional transesophageal echocardiography (3DTEE) planimetry (MVA(3D)); 2) to compare MVA(3D) with conventional techniques: 2-dimensional (2D) planimetry (MVA(2D)), pressure half-time (MVA(PHT)), and continuity equation (MVA(CON)); and 3) to evaluate the degree of mitral commissural fusion. 3DTEE is a novel technique that provides excellent image quality of the mitral valve. Real-time 3DTEE is a relatively recent enhancement of this technique. To date, there have been no feasibility studies investigating the utility of real-time 3DTEE in the assessment of RhMS. Forty-three consecutive patients referred for echocardiographic evaluation of RhMS and suitability for percutaneous mitral valvuloplasty were assessed using 2D transthoracic echocardiography and real-time 3DTEE. MVA(3D), MVA(2D), MVA(PHT), MVA(CON), and the degree of commissural fusion were evaluated. MVA(3D) assessment was possible in 41 patients (95%). MVA(3D) measurements were significantly lower compared with MVA(2D) (mean difference: -0.16 ± 0.22; n=25, p<0.005) and MVA(PHT) (mean difference: -0.23 ± 0.28 cm(2); n=39, p<0.0001) but marginally greater than MVA(CON) (mean difference: 0.05 ± 0.22 cm(2); n=24, p=0.82). MVA(3D) demonstrated best agreement with MVA(CON) (intraclass correlation coefficient [ICC] 0.83), followed by MVA(2D) (ICC 0.79) and MVA(PHT) (ICC 0.58). Interobserver and intraobserver agreement was excellent for MVA(3D), with ICCs of 0.93 and 0.96, respectively. Excellent commissural evaluation was possible in all patients using 3DTEE. Compared with 3DTEE, underestimation of the degree of commissural fusion using 2D transthoracic echocardiography was observed in 19%, with weak agreement between methods (κ<0.4). MVA planimetry is feasible in the majority of patients with RhMS using 3DTEE, with excellent reproducibility, and compares favorably with established methods. Three-dimensional transesophageal echocardiography allows excellent assessment of commissural fusion. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Dry powder aerosols generated by standardized entrainment tubes from alternative sugar blends: 3. Trehalose dihydrate and D-mannitol carriers.

    PubMed

    Mansour, Heidi M; Xu, Zhen; Hickey, Anthony J

    2010-08-01

    The relationship between physicochemical properties of drug/carrier blends and aerosol drug powder delivery was evaluated. Four pulmonary drugs each representing the major pulmonary therapeutic classes and with a different pharmacological action were employed. Specifically, the four pulmonary drugs were albuterol sulfate, ipratropium bromide monohydrate, disodium cromoglycate, and fluticasone propionate. The two carrier sugars, each representing a different sugar class, were D-mannitol and trehalose dihydrate. Dry powder aerosols (2%, w/w, drug in carrier) delivered using standardized entrainment tubes (SETs) were characterized by twin-stage liquid impinger. The fine particle fraction (FPF) was correlated with SET shear stress, tau(s), and the maximum fine particle fraction (FPF(max)) was correlated with a deaggregation constant, k(d), by using a powder aerosol deaggregation equation (PADE) by nonlinear and linear regression analyses applied to pharmaceutical inhalation aerosol systems in the solid state. For the four pulmonary drugs representing the major pulmonary therapeutic classes and two chemically distinct pulmonary sugar carriers (non-lactose types) aerosolized with SETs having well-defined shear stress values, excellent correlation and predictive relationships were demonstrated for the novel and rigorous application of PADE for dry powder inhalation aerosol dispersion within a well-defined shear stress range, in the context of pulmonary drug/sugar carrier physicochemical and interfacial properties. (c) 2010 Wiley-Liss, Inc. and the American Pharmacists Association

  10. Reliability and validity of young adults’ anonymous online reports of marijuana use and thoughts about use

    PubMed Central

    Ramo, Danielle E.; Liu, Howard; Prochaska, Judith J.

    2012-01-01

    With growing interest in online assessment of substance abuse behaviors, there is a need to formally evaluate the validity of the data gathered. The current investigation evaluated the reliability and validity of anonymous, online reports of young adults’ marijuana use and related cognitions. Young adults age 18 to 25 who had smoked at least one cigarette in the past 30 days were recruited over 14 months to complete an anonymous online survey. Of 3106 eligible cases, 1617 (52%) completed the entire survey. Of those, 54% (n = 884) reported past-month marijuana use (65% male, 70% Caucasian, mean age was 20.4 years [SD = 2.0]). Prevalence of marijuana use was reported reliably across three similar items, and inter-item correlations ranged from fair to excellent for measures of marijuana dependence symptoms and thoughts about marijuana use. Marijuana use frequency demonstrated good construct validity through expected correlations with marijuana use constructs, and non-significant correlations with thoughts about tobacco use. Marijuana frequency distinguished among stages of change for marijuana use and goals for use, but not among gender, ethnicity, or employment groups. Marijuana use and thoughts about use differed by stage of change in the hypothesized directions. Self-reported marijuana use and associated cognitions reported anonymously online from young adults are generally reliable and valid. Online assessments of substance use broaden the reach of addictions research. PMID:22082344

  11. Chinese adaptation and validation of the patellofemoral pain severity scale.

    PubMed

    Cheung, Roy T H; Ngai, Shirley P C; Lam, Priscillia L; Chiu, Joseph K W; Fung, Eric Y H

    2013-05-01

    This study validated the Patellofemoral Pain Severity Scale translated into Chinese. The Chinese Patellofemoral Pain Severity Scale was translated from the original English version following standard forward and backward translation procedures recommended by the International Society for Pharmacoeconomics and Outcomes Research. The survey was then conducted in clinical settings by a questionnaire comprising the Chinese Patellofemoral Pain Severity Scale, Kujala Scale and Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index. Eighty-four Chinese reading patients with patellofemoral pain were recruited from physical therapy clinics. Internal consistency of the translated instrument was measured by Cronbach alpha. Convergent validity was examined by Spearman rank correlation coefficient (rho) tests by comparing its score with the validated Chinese version of the Kujala Scale and the WOMAC Osteoarthritis Index while the test-retest reliability was evaluated by administering the questionnaires twice. Cronbach alpha values of individual questions and their overall value were above 0.85. Strong association was found between the Chinese Patellofemoral Pain Severity Scale and the Kujala Scale (rho = -0.72, p < 0.001). Moderate correlation was also found between Chinese Patellofemoral Pain Severity Scale with the WOMAC Osteoarthritis Index (rho = 0.63, p < 0.001). Excellent test-retest reliability (Intraclass correlation coefficient = 0.98) was demonstrated. The Chinese translated version of the Patellofemoral Pain Severity Scale is a reliable and valid instrument for patients with patellofemoral pain.

  12. A novel theoretical probe of the SrTiO3 surface under water-splitting conditions

    NASA Astrophysics Data System (ADS)

    Letchworth-Weaver, Kendra; Gunceler, Deniz; Arias, Tomás; Plaza, Manuel; Huang, Xin; Brock, Joel; Rodriguez-López, Joaquin; Abruña, Hector

    2014-03-01

    Understanding the reaction mechanisms required to generate hydrogen fuel by photoelectrolysis of water is essential to energy conversion research. These reaction pathways are strongly influenced by the geometry and electronic structure of the electrode surface under water-splitting conditions. Electrochemical microscopy has demonstrated that biasing a SrTiO3 (001) surface can lead to an increase in water-splitting activity. In operando X-ray reflectivity measurements at the Cornell High Energy Synchrotron Source (CHESS) correlate this increase in activity to a significant reorganization in the surface structure but are unable to determine the exact nature of this change. Joint Density-Functional Theory (JDFT), a rigorous yet computationally efficient alternative to molecular dynamics, provides a quantum-mechanical description of an electrode surface in contact with an aqueous environment, and a microscopically detailed description of the interfacial liquid structure. Our JDFT calculations determine the structure of the activated SrTiO3 surface and explore why it is correlated with higher activity for water splitting. With no empirical parameters whatsoever, we predict the X-ray crystal truncation rods for SrTiO3, finding excellent agreement with experiment. Funded by the Energy Materials Center at Cornell (EMC2).

  13. Correlation between Hox code and vertebral morphology in archosaurs.

    PubMed

    Böhmer, Christine; Rauhut, Oliver W M; Wörheide, Gert

    2015-07-07

    The relationship between developmental genes and phenotypic variation is of central interest in evolutionary biology. An excellent example is the role of Hox genes in the anteroposterior regionalization of the vertebral column in vertebrates. Archosaurs (crocodiles, dinosaurs including birds) are highly variable both in vertebral morphology and number. Nevertheless, functionally equivalent Hox genes are active in the axial skeleton during embryonic development, indicating that the morphological variation across taxa is likely owing to modifications in the pattern of Hox gene expression. By using geometric morphometrics, we demonstrate a correlation between vertebral Hox code and quantifiable vertebral morphology in modern archosaurs, in which the boundaries between morphological subgroups of vertebrae can be linked to anterior Hox gene expression boundaries. Our findings reveal homologous units of cervical vertebrae in modern archosaurs, each with their specific Hox gene pattern, enabling us to trace these homologies in the extinct sauropodomorph dinosaurs, a group with highly variable vertebral counts. Based on the quantifiable vertebral morphology, this allows us to infer the underlying genetic mechanisms in vertebral evolution in fossils, which represents not only an important case study, but will lead to a better understanding of the origin of morphological disparity in recent archosaur vertebral columns.

  14. Correlation between Hox code and vertebral morphology in archosaurs

    PubMed Central

    Böhmer, Christine; Rauhut, Oliver W. M.; Wörheide, Gert

    2015-01-01

    The relationship between developmental genes and phenotypic variation is of central interest in evolutionary biology. An excellent example is the role of Hox genes in the anteroposterior regionalization of the vertebral column in vertebrates. Archosaurs (crocodiles, dinosaurs including birds) are highly variable both in vertebral morphology and number. Nevertheless, functionally equivalent Hox genes are active in the axial skeleton during embryonic development, indicating that the morphological variation across taxa is likely owing to modifications in the pattern of Hox gene expression. By using geometric morphometrics, we demonstrate a correlation between vertebral Hox code and quantifiable vertebral morphology in modern archosaurs, in which the boundaries between morphological subgroups of vertebrae can be linked to anterior Hox gene expression boundaries. Our findings reveal homologous units of cervical vertebrae in modern archosaurs, each with their specific Hox gene pattern, enabling us to trace these homologies in the extinct sauropodomorph dinosaurs, a group with highly variable vertebral counts. Based on the quantifiable vertebral morphology, this allows us to infer the underlying genetic mechanisms in vertebral evolution in fossils, which represents not only an important case study, but will lead to a better understanding of the origin of morphological disparity in recent archosaur vertebral columns. PMID:26085583

  15. Assessment of the accuracy of a new tool for the screening of smartphone addiction.

    PubMed

    Khoury, Julia Machado; de Freitas, André Augusto Corrêa; Roque, Marco Antônio Valente; Albuquerque, Maicon Rodrigues; das Neves, Maila de Castro Lourenço; Garcia, Frederico Duarte

    2017-01-01

    To translate, adapt and validate the Smartphone Addiction Inventory (SPAI) in a Brazilian population of young adults. We employed the translation and back-translation method for the adaptation of the Brazilian version SPAI (SPAI-BR). The sample consisted of 415 university students. Data was collected through an electronic questionnaire, which consisted of the SPAI-BR and the Goodman Criteria (gold standard). The retests were carried out 10-15 days after the initial tests with 130 individuals. The SPAI-BR maintained semantic, idiomatic and conceptual equivalences from the original scale. The Confirmatory Factor Analysis confirmed the One-factor model of the SPAI with good fit indexes (x2 = 767.861, CFI = 0.913, TLI = 0.905, RMSE = 0.061, WRMR = 1.465). The Kuder-Richardson Coefficient showed good internal consistency. The analysis of the ROC curve established an area under the curve of 86.38%. The Intraclass-Correlation Coefficient of 0.926 between the test and the retest demonstrated an excellent temporal stability. The high correlation between SPAI-BR and the Goodman Criteria (rs = 0.750) established the convergent validity. The SPAI-BR is a valid and reliable tool for the detection of Smartphone Addiction in Brazilian university students.

  16. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    PubMed

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  17. Astronomical algorithms for automated analysis of tissue protein expression in breast cancer

    PubMed Central

    Ali, H R; Irwin, M; Morris, L; Dawson, S-J; Blows, F M; Provenzano, E; Mahler-Araujo, B; Pharoah, P D; Walton, N A; Brenton, J D; Caldas, C

    2013-01-01

    Background: High-throughput evaluation of tissue biomarkers in oncology has been greatly accelerated by the widespread use of tissue microarrays (TMAs) and immunohistochemistry. Although TMAs have the potential to facilitate protein expression profiling on a scale to rival experiments of tumour transcriptomes, the bottleneck and imprecision of manually scoring TMAs has impeded progress. Methods: We report image analysis algorithms adapted from astronomy for the precise automated analysis of IHC in all subcellular compartments. The power of this technique is demonstrated using over 2000 breast tumours and comparing quantitative automated scores against manual assessment by pathologists. Results: All continuous automated scores showed good correlation with their corresponding ordinal manual scores. For oestrogen receptor (ER), the correlation was 0.82, P<0.0001, for BCL2 0.72, P<0.0001 and for HER2 0.62, P<0.0001. Automated scores showed excellent concordance with manual scores for the unsupervised assignment of cases to ‘positive' or ‘negative' categories with agreement rates of up to 96%. Conclusion: The adaptation of astronomical algorithms coupled with their application to large annotated study cohorts, constitutes a powerful tool for the realisation of the enormous potential of digital pathology. PMID:23329232

  18. A quick and reliable procedure for assessing foot alignment in athletes.

    PubMed

    De Michelis Mendonça, Luciana; Bittencourt, Natália Franco Netto; Amaral, Giovanna Mendes; Diniz, Lívia Santos; Souza, Thales Rezende; da Fonseca, Sérgio Teixeira

    2013-01-01

    Quick procedures with proper psychometric properties that can capture the combined alignment of the foot-ankle complex in a position that may be more representative of the status of the lower limb during ground contact are essential for assessing a large group of athletes. The assessed lower limb was positioned with the calcaneus surface facing upward in a way that all of the marks could be seen at the center of the camera display. After guaranteeing maintenance of the foot at 90° of dorsiflexion actively sustained by the athlete, the examiner took the picture of the foot-ankle alignment. Intraclass correlation coefficients ranging from 0.82 to 0.93 demonstrated excellent intratester and intertester reliability for the proposed measurements of forefoot, rearfoot, and shank-forefoot alignments. The intraclass correlation coefficient between the shank-forefoot measures and the sum of the rearfoot and forefoot measures was 0.98, suggesting that the shank-forefoot alignment measures can represent the combined rearfoot and forefoot alignments. This study describes a reliable and practical measurement procedure for rearfoot, forefoot, and shank-forefoot alignments that can be applied to clinical and research situations as a screening procedure for risk factors for lower-limb injuries in athletes.

  19. Rapid Assessment of Salivary MMP-8 and Periodontal Disease Using Lateral Flow Immunoassay

    PubMed Central

    Johnson, N.; Ebersole, J.L.; Kryscio, R.J.; Danaher, R. J.; Dawson, D.; Al-Sabbagh, M.; Miller, C.S.

    2016-01-01

    Objective This study determined the efficacy of a novel point-of-care immunoflow device (POCID) for detecting matrix metalloproteinase (MMP)-8 concentrations in oral fluids in comparison with a gold-standard laboratory-based immunoassay. Methods Oral rinse fluid and whole expectorated saliva samples were collected from 41 participants clinically classified as periodontally healthy or diseased. Samples were analyzed for MMP-8 by Luminex immunoassay and POCID. Photographed POCID results were assessed by optical scan and visually by two examiners. Data were analyzed by Pearson correlation and receiver operator characteristics. Results MMP-8 was readily detected by the POCID, and concentrations correlated well with Luminex for both saliva and rinse fluids (r=0.57–0.93). Thresholds that distinguished periodontitis from health were delineated from both the optical scans and visual reads of the POCID (sensitivity 0.7–0.9, specificity 0.5–0.7; p < 0.05). Conclusions Performance of this POCID for detecting MMP-8 in oral rinse fluid or saliva was excellent. These findings help demonstrate the utility of salivary biomarkers for distinguishing periodontal disease from health using a rapid point-of-care approach. PMID:27273425

  20. Construct validity, test-retest reliability and internal consistency of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) in patients with carpal tunnel syndrome.

    PubMed

    Buntragulpoontawee, Montana; Phutrit, Suphatha; Tongprasert, Siam; Wongpakaran, Tinakon; Khunachiva, Jeeranan

    2018-03-27

    This study evaluated additional psychometric properties of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) which included, test-retest reliability, construct validity, internal consistency of in patients with carpal tunnel syndrome. As for determining construct validity, the Thai EuroQOL questionnaire (EQ-5D-5L) was also administered in order to examine convergent and divergent validity. Fifty patients completed both questionnaires. The DASH-TH showed excellent test-retest reliability (intraclass correlation coefficient = 0.811) and internal consistency (Cronbach's alpha = 0.911). The exploratory factor analysis yielded a six-factor solution while the confirmatory factor analysis denoted that the hypothesized model adequately fit the data with a comparative fit index of 0.967 and a Tucker-Lewis index of 0.964. The related subscales between the DASH-TH and the Thai EQ-5D-5L were significantly correlated, indicating the DASH-TH's convergent and discriminant validity. The DASH-TH demonstrated good reliability, internal consistency construct validity, and multidimensionality, in assessing the upper extremity function in carpal tunnel syndrome patients.

  1. Anharmonicity Rise the Thermal Conductivity in Amorphous Silicon

    NASA Astrophysics Data System (ADS)

    Lv, Wei; Henry, Asegun

    We recently proposed a new method called Direct Green-Kubo Modal Analysis (GKMA) method, which has been shown to calculate the thermal conductivity (TC) of several amorphous materials accurately. A-F method has been widely used for amorphous materials. However, researchers have found out that it failed on several different materials. The missing component of A-F method is the harmonic approximation and considering only the interactions of modes with similar frequencies, which neglect interactions of modes with large frequency difference. On the contrary, GKMA method, which is based on molecular dynamics, intrinsically includes all types of phonon interactions. In GKMA method, each mode's TC comes from both mode self-correlations (autocorrelations) and mode-mode correlations (crosscorrelations). We have demonstrated that the GKMA predicted TC of a-Si from Tersoff potential is in excellent agreement with one of experimental results. In this work, we will present the GKMA applications on a-Si using multiple potentials and gives us more insight of the effect of anharmonicity on the TC of amorphous silicon. This research was supported Intel grant AGMT DTD 1-15-13 and computational resources by NSF supported XSEDE resources under allocations DMR130105 and TG- PHY130049.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anthony, R.W.; Bodig, J.; Phillips, G.E.

    This report describes the development of a nondestructive evaluation (NDE) methodology for assessing the bending strength of new wood utility poles. Fundamental concepts of stress wave propagation are presented. The development of a longitudinal stress wave methodology for predicting pole strength and the results of destructive tests on full-size poles are described. Mathematical correlations between stress wave parameters, geometric characteristics, and individual pole bending strengths form the basis of strength prediction models for western redcedar, Douglas-fir and southern pine poles. Models were developed for NDE in the whitewood stage and after preservative treatment of poles. For each species the twomore » most commonly used preservative types were evaluated. Excellent correlations were obtained for western redcedar and Douglas-fir poles, but high moisture content in the southern pine poles resulted in lower prediction accuracies for this species. Verification of the developed mathematical models demonstrates that improvement in classifying poles into the ANSI 05.1 tip-load capacities is technically feasible. The development and field trial of the prototype equipment for strength grading of new poles is also described. Research results can be used to benefit utilities by enabling the supply of strength graded poles with a higher accuracy than previously possible.« less

  3. Competition of mesoscales and crossover to theta-point tricriticality in near-critical polymer solutions.

    PubMed

    Anisimov, M A; Kostko, A F; Sengers, J V; Yudin, I K

    2005-10-22

    The approach to asymptotic critical behavior in polymer solutions is governed by a competition between the correlation length of critical fluctuations diverging at the critical point of phase separation and an additional mesoscopic length scale, the radius of gyration. In this paper we present a theory for crossover between two universal regimes: a regime with Ising (fluctuation-induced) asymptotic critical behavior, where the correlation length prevails, and a mean-field tricritical regime with theta-point behavior controlled by the mesoscopic polymer chain. The theory yields a universal scaled description of existing experimental phase-equilibria data and is in excellent agreement with our light-scattering experiments on polystyrene solutions in cyclohexane with polymer molecular weights ranging from 2 x 10(5) up to 11.4 x 10(6). The experiments demonstrate unambiguously that crossover to theta-point tricriticality is controlled by a competition of the two mesoscales. The critical amplitudes deduced from our experiments depend on the polymer molecular weight as predicted by de Gennes [Phys. Lett. 26A, 313 (1968)]. Experimental evidence for the presence of logarithmic corrections to mean-field tricritical theta-point behavior in the molecular-weight dependence of the critical parameters is also presented.

  4. An add-in implementation of the RESAMPLING syntax under Microsoft EXCEL.

    PubMed

    Meineke, I

    2000-10-01

    The RESAMPLING syntax defines a set of powerful commands, which allow the programming of probabilistic statistical models with few, easily memorized statements. This paper presents an implementation of the RESAMPLING syntax using Microsoft EXCEL with Microsoft WINDOWS(R) as a platform. Two examples are given to demonstrate typical applications of RESAMPLING in biomedicine. Details of the implementation with special emphasis on the programming environment are discussed at length. The add-in is available electronically to interested readers upon request. The use of the add-in facilitates numerical statistical analyses of data from within EXCEL in a comfortable way.

  5. Repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography macular metrics in healthy subjects.

    PubMed

    Fang, Danqi; Tang, Fang Yao; Huang, Haifan; Cheung, Carol Y; Chen, Haoyu

    2018-05-29

    To investigate the repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography (SS-OCTA) metrics in healthy subjects. Thirty-three healthy normal subjects were enrolled. The macula was scanned four times by an SS-OCTA system using the 3 mm×3 mm mode. The superficial capillary map images were analysed using a MATLAB program. A series of parameters were measured: foveal avascular zone (FAZ) area, FAZ perimeter, FAZ circularity, parafoveal vessel density, fractal dimension and vessel diameter index (VDI). The repeatability of four scans was determined by intraclass correlation coefficient (ICC). Then the averaged results were analysed for intereye difference, correlation and agreement using paired t-test, Pearson's correlation coefficient (r), ICC and Bland-Altman plot. The repeatability assessment of the macular metrics exported high ICC values (ranged from 0.853 to 0.996). There is no statistically significant difference in the OCTA metrics between the two eyes. FAZ area (ICC=0.961, r=0.929) and FAZ perimeter (ICC=0.884, r=0.802) showed excellent binocular correlation. Fractal dimension (ICC=0.732, r=0.578) and VDI (ICC=0.707, r=0.547) showed moderate binocular correlation, while parafoveal vessel density had poor binocular correlation. Bland-Altman plots showed the range of agreement was from -0.0763 to 0.0954 mm 2 for FAZ area and from -0.0491 to 0.1136 for parafoveal vessel density. The macular metrics obtained using SS-OCTA showed excellent repeatability in healthy subjects. We showed high intereye correlation in FAZ area and perimeter, moderate correlation in fractal dimension and VDI, while vessel density had poor correlation in normal healthy subjects. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. X-ray microbeam three-dimensional topography for dislocation strain-field analysis of 4H-SiC

    NASA Astrophysics Data System (ADS)

    Tanuma, R.; Mori, D.; Kamata, I.; Tsuchida, H.

    2013-07-01

    This paper describes the strain-field analysis of threading edge dislocations (TEDs) and basal-plane dislocations (BPDs) in 4H-SiC using x-ray microbeam three-dimensional (3D) topography. This 3D topography enables quantitative strain-field analysis, which measures images of effective misorientations (Δω maps) around the dislocations. A deformation-matrix-based simulation algorithm is developed to theoretically evaluate the Δω mapping. Systematic linear calculations can provide simulated Δω maps (Δωsim maps) of dislocations with different Burgers vectors, directions, and reflection vectors for the desired cross-sections. For TEDs and BPDs, Δω maps are compared with Δωsim maps, and their excellent correlation is demonstrated. Two types of asymmetric reflections, high- and low-angle incidence types, are compared. Strain analyses are also conducted to investigate BPD-TED conversion near an epilayer/substrate interface in 4H-SiC.

  7. Validation of French and German versions of a Perceived Neighborhood Social Cohesion Questionnaire among young Swiss males, and its relationship with substance use.

    PubMed

    Dupuis, Marc; Studer, Joseph; Henchoz, Yves; Deline, Stéphane; Baggio, Stéphanie; N'Goran, Alexandra; Mohler-Kuo, Meichun; Gmel, Gerhard

    2016-02-01

    This study main purpose was the validation of both French and German versions of a Perceived Neighborhood Social Cohesion Questionnaire. The sample group comprised 5065 Swiss men from the "Cohort Study on Substance Use Risk Factors." Multigroup Confirmatory factor analysis showed that a three-factor model fits the data well, which substantiates the generalizability of Perceived Neighborhood Social Cohesion Questionnaire factor structure, regardless of the language. The Perceived Neighborhood Social Cohesion Questionnaire demonstrated excellent homogeneity (α = 95) and split-half reliability (r = .96). The Perceived Neighborhood Social Cohesion Questionnaire was sensitive to community size and participants' financial situation, confirming that it also measures real social conditions. Finally, weak but frequent correlations between Perceived Neighborhood Social Cohesion Questionnaire and alcohol, cigarette, and cannabis dependence were measured. © The Author(s) 2014.

  8. Highly efficient all-nitride phosphor-converted white light emitting diode

    NASA Astrophysics Data System (ADS)

    Mueller-Mach, Regina; Mueller, Gerd; Krames, Michael R.; Höppe, Henning A.; Stadler, Florian; Schnick, Wolfgang; Juestel, Thomas; Schmidt, Peter

    2005-07-01

    The development and demonstration of a highly efficient warm-white all-nitride phosphor-converted light emitting diode (pc-LED) is presented utilizing a GaN based quantum well blue LED and two novel nitrogen containing luminescent materials, both of which are doped with Eu2+. For color conversion of the primary blue the nitridosilicates M2Si5N8 (orange-red) and MSi2O2N2 (yellow-green), with M = alkaline earth, were employed, thus achieving a high luminous efficiency (25 lumen/W at 1 W input), excellent color quality (correlated color temperature CCT = 3200 K, general color rendering index Ra > 90) and the highest proven color stability of any pc-LED obtained so far. Thus, these novel all-nitride LEDs are superior to both incandescent and fluorescent lamps and may therefore become the next generation of general lighting sources.

  9. Evidence for radical anion formation during liquid secondary ion mass spectrometry analysis of oligonucleotides and synthetic oligomeric analogues: a deconvolution algorithm for molecular ion region clusters.

    PubMed

    Laramée, J A; Arbogast, B; Deinzer, M L

    1989-10-01

    It is shown that one-electron reduction is a common process that occurs in negative ion liquid secondary ion mass spectrometry (LSIMS) of oligonucleotides and synthetic oligonucleosides and that this process is in competition with proton loss. Deconvolution of the molecular anion cluster reveals contributions from (M-2H).-, (M-H)-, M.-, and (M + H)-. A model based on these ionic species gives excellent agreement with the experimental data. A correlation between the concentration of species arising via one-electron reduction [M.- and (M + H)-] and the electron affinity of the matrix has been demonstrated. The relative intensity of M.- is mass-dependent; this is rationalized on the basis of base-stacking. Base sequence ion formation is theorized to arise from M.- radical anion among other possible pathways.

  10. Lithological mapping using Landsat 8 OLI and Terra ASTER multispectral data in the Bas Drâa inlier, Moroccan Anti Atlas

    NASA Astrophysics Data System (ADS)

    Adiri, Zakaria; Harti, Abderrazak El; Jellouli, Amine; Maacha, Lhou; Bachaoui, El Mostafa

    2016-01-01

    Lithological mapping is a fundamental step in various mineral prospecting studies because it forms the basis of the interpretation and validation of retrieved results. Therefore, this study exploited the multispectral Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and Landsat 8 Operational Land Imager (OLI) data in order to map lithological units in the Bas Drâa inlier, at the Moroccan Anti Atlas. This task was completed by using principal component analysis (PCA), band ratios (BR), and support vector machine (SVM) classification. Overall accuracy and the kappa coefficient of SVM based on ground truth in addition to the results of PCA and BR show an excellent correlation with the existing geological map of the study area. Consequently, the methodology proposed demonstrates a high potential of ASTER and Landsat 8 OLI data in lithological units discrimination.

  11. A novel spinal kinematic analysis using X-ray imaging and vicon motion analysis: a case study.

    PubMed

    Noh, Dong K; Lee, Nam G; You, Joshua H

    2014-01-01

    This study highlights a novel spinal kinematic analysis method and the feasibility of X-ray imaging measurements to accurately assess thoracic spine motion. The advanced X-ray Nash-Moe method and analysis were used to compute the segmental range of motion in thoracic vertebra pedicles in vivo. This Nash-Moe X-ray imaging method was compared with a standardized method using the Vicon 3-dimensional motion capture system. Linear regression analysis showed an excellent and significant correlation between the two methods (R2 = 0.99, p < 0.05), suggesting that the analysis of spinal segmental range of motion using X-ray imaging measurements was accurate and comparable to the conventional 3-dimensional motion analysis system. Clinically, this novel finding is compelling evidence demonstrating that measurements with X-ray imaging are useful to accurately decipher pathological spinal alignment and movement impairments in idiopathic scoliosis (IS).

  12. Optical measurement of high-temperature melt flow rate.

    PubMed

    Bizjan, Benjamin; Širok, Brane; Chen, Jinpeng

    2018-05-20

    This paper presents an optical method and system for contactless measurement of the mass flow rate of melts by digital cameras. The proposed method is based on reconstruction of melt stream geometry and flow velocity calculation by cross correlation, and is very cost-effective due its modest hardware requirements. Using a laboratory test rig with a small inductive melting pot and reference mass flow rate measurement by weighing, the proposed method was demonstrated to have an excellent dynamic response (0.1 s order of magnitude) while producing deviations from the reference of about 5% in the steady-state flow regime. Similar results were obtained in an industrial stone wool production line for two repeated measurements. Our method was tested in a wide range of melt flow rates (0.05-1.2 kg/s) and did not require very fast cameras (120 frames per second would be sufficient for most industrial applications).

  13. Layered double hydroxide using hydrothermal treatment: morphology evolution, intercalation and release kinetics of diclofenac sodium

    NASA Astrophysics Data System (ADS)

    Joy, Mathew; Iyengar, Srividhya J.; Chakraborty, Jui; Ghosh, Swapankumar

    2017-12-01

    The present work demonstrates the possibilities of hydrothermal transformation of Zn-Al layered double hydroxide (LDH) nanostructure by varying the synthetic conditions. The manipulation in washing step before hydrothermal treatment allows control over crystal morphologies, size and stability of their aqueous solutions. We examined the crystal growth process in the presence and the absence of extra ions during hydrothermal treatment and its dependence on the drug (diclofenac sodium (Dic-Na)) loading and release processes. Hexagonal plate-like crystals show sustained release with ˜90% of the drug from the matrix in a week, suggesting the applicability of LDH nanohybrids in sustained drug delivery systems. The fits to the release kinetics data indicated the drug release as a diffusion-controlled release process. LDH with rod-like morphology shows excellent colloidal stability in aqueous suspension, as studied by photon correlation spectroscopy.

  14. Reliability of infrared thermometric measurements of skin temperature in the hand.

    PubMed

    Packham, Tara L; Fok, Diana; Frederiksen, Karen; Thabane, Lehana; Buckley, Norman

    2012-01-01

    Clinical measurement study. Skin temperature asymmetries (STAs) are used in the diagnosis of complex regional pain syndrome (CRPS), but little evidence exists for reliability of the equipment and methods. This study examined the reliability of an inexpensive infrared (IR) thermometer and measurement points in the hand for the study of STA. ST was measured three times at five points on both hands with an IR thermometer by two raters in 20 volunteers (12 normals and 8 CRPS). ST measurement results using IR thermometers support inter-rater reliability: intraclass correlation coefficient (ICC) estimate for single measures 0.80; all ST measurement points were also highly reliable (ICC single measures, 0.83-0.91). The equipment demonstrated excellent reliability, with little difference in the reliability of the five measurement sites. These preliminary findings support their use in future CRPS research. Not applicable. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  15. Psychometric evaluation of the Social Interaction Phobia Scale.

    PubMed

    Reilly, Alison R; Carleton, R Nicholas; Weeks, Justin W

    2012-01-01

    The present study evaluated the psychometric properties of a novel measure of social anxiety symptoms, the Social Interaction Phobia Scale (SIPS), as a stand-alone item set, using an undergraduate sample (N=512). The 14-item SIPS has three subscales assessing Social Interaction Anxiety, Fear of Overt Evaluation, and Fear of Attracting Attention. Confirmatory factor analyses replicated the three-factor structure for the SIPS originally reported by Carleton et al. All SIPS scores demonstrated good internal consistency. The convergent validity of the SIPS was supported by strong and positive correlations between all SIPS scores and measures of social anxiety and fear of evaluation; the finding that the relationships between all SIPS scores and a social anxiety measure were stronger than relationships between all SIPS scores and measures of other constructs supported the discriminant validity of the SIPS. Results suggest that the SIPS possesses excellent psychometric properties.

  16. Smart phone: a popular device supports amylase activity assay in fisheries research.

    PubMed

    Thongprajukaew, Karun; Choodum, Aree; Sa-E, Barunee; Hayee, Ummah

    2014-11-15

    Colourimetric determinations of amylase activity were developed based on a standard dinitrosalicylic acid (DNS) staining method, using maltose as the analyte. Intensities and absorbances of red, green and blue (RGB) were obtained with iPhone imaging and Adobe Photoshop image analysis. Correlation of green and analyte concentrations was highly significant, and the accuracy of the developed method was excellent in analytical performance. The common iPhone has sufficient imaging ability for accurate quantification of maltose concentrations. Detection limits, sensitivity and linearity were comparable to a spectrophotometric method, but provided better inter-day precision. In quantifying amylase specific activity from a commercial source (P>0.02) and fish samples (P>0.05), differences compared with spectrophotometric measurements were not significant. We have demonstrated that iPhone imaging with image analysis in Adobe Photoshop has potential for field and laboratory studies of amylase. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. [Roles of additives and surface control in slurry atomization]. Quarterly report, March 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-08-01

    Our experimental results clearly demonstrate that the shape of particles with aspect ratio close to unity dictates the relative suspension viscosity. Suspensions of irregularly shaped particles have higher relative viscosities than suspensions of spherical particles at same volume fractions, in agreement with the reported results at high shear conditions. The relative viscosity of a Newtonian suspension is in excellent agreement with that predicted by the Krieger/Dougherty rigid sphere model using the maximum packing fraction determined from sedimentation as the sole parameter. The relative viscosity of a pseudoplastic suspension is independent of the particle density. It correlates well with the particlemore » Peclet number. The extent of particle diffusion at high shear rates decreases considerably as the particle size increases, and less energy is dissipated as a result. The interparticle electrostatic repulsion plays no significant role in the rheology of pseudoplastic nonaqueous and aqueous glycerol suspensions of noncolloidal particles.« less

  18. (Roles of additives and surface control in slurry atomization)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-01-01

    Our experimental results clearly demonstrate that the shape of particles with aspect ratio close to unity dictates the relative suspension viscosity. Suspensions of irregularly shaped particles have higher relative viscosities than suspensions of spherical particles at same volume fractions, in agreement with the reported results at high shear conditions. The relative viscosity of a Newtonian suspension is in excellent agreement with that predicted by the Krieger/Dougherty rigid sphere model using the maximum packing fraction determined from sedimentation as the sole parameter. The relative viscosity of a pseudoplastic suspension is independent of the particle density. It correlates well with the particlemore » Peclet number. The extent of particle diffusion at high shear rates decreases considerably as the particle size increases, and less energy is dissipated as a result. The interparticle electrostatic repulsion plays no significant role in the rheology of pseudoplastic nonaqueous and aqueous glycerol suspensions of noncolloidal particles.« less

  19. Simple analytical model for low-frequency frequency-modulation noise of monolithic tunable lasers.

    PubMed

    Huynh, Tam N; Ó Dúill, Seán P; Nguyen, Lim; Rusch, Leslie A; Barry, Liam P

    2014-02-10

    We employ simple analytical models to construct the entire frequency-modulation (FM)-noise spectrum of tunable semiconductor lasers. Many contributions to the laser FM noise can be clearly identified from the FM-noise spectrum, such as standard Weiner FM noise incorporating laser relaxation oscillation, excess FM noise due to thermal fluctuations, and carrier-induced refractive index fluctuations from stochastic carrier generation in the passive tuning sections. The contribution of the latter effect is identified by noting a correlation between part of the FM-noise spectrum with the FM-modulation response of the passive sections. We pay particular attention to the case of widely tunable lasers with three independent tuning sections, mainly the sampled-grating distributed Bragg reflector laser, and compare with that of a distributed feedback laser. The theoretical model is confirmed with experimental measurements, with the calculations of the important phase-error variance demonstrating excellent agreement.

  20. Combustion of hydrogen injected into a supersonic airstream (a guide to the HISS computer program)

    NASA Technical Reports Server (NTRS)

    Dyer, D. F.; Maples, G.; Spalding, D. B.

    1976-01-01

    A computer program based on a finite-difference, implicit numerical integration scheme is described for the prediction of hydrogen injected into a supersonic airstream at an angle ranging from normal to parallel to the airstream main flow direction. Results of calculations for flow and thermal property distributions were compared with 'cold flow data' taken by NASA/Langley and show excellent correlation. Typical results for equilibrium combustion are presented and exhibit qualitatively plausible behavior. Computer time required for a given case is approximately one minute on a CDC 7600. A discussion of the assumption of parabolic flow in the injection region is given which demonstrates that improvement in calculation in this region could be obtained by a partially-parabolic procedure which has been developed. It is concluded that the technique described provides an efficient and reliable means for analyzing hydrogen injection into supersonic airstreams and the subsequent combustion.

  1. FLASH free-electron laser single-shot temporal diagnostic: terahertz-field-driven streaking.

    PubMed

    Ivanov, Rosen; Liu, Jia; Brenner, Günter; Brachmanski, Maciej; Düsterer, Stefan

    2018-01-01

    The commissioning of a terahertz-field-driven streak camera installed at the free-electron laser (FEL) FLASH at DESY in Hamburg, being able to deliver photon pulse duration as well as arrival time information with ∼10 fs resolution for each single XUV FEL pulse, is reported. Pulse durations between 300 fs and <15 fs have been measured for different FLASH FEL settings. A comparison between the XUV pulse arrival time and the FEL electron bunch arrival time measured at the FLASH linac section exhibits a correlation width of 20 fs r.m.s., thus demonstrating the excellent operation stability of FLASH. In addition, the terahertz-streaking setup was operated simultaneously to an alternative method to determine the FEL pulse duration based on spectral analysis. FLASH pulse duration derived from simple spectral analysis is in good agreement with that from terahertz-streaking measurement.

  2. Ferroelectric Sm-Doped BiMnO3 Thin Films with Ferromagnetic Transition Temperature Enhanced to 140 K

    PubMed Central

    2014-01-01

    A combined chemical pressure and substrate biaxial pressure crystal engineering approach was demonstrated for producing highly epitaxial Sm-doped BiMnO3 (BSMO) films on SrTiO3 single crystal substrates, with enhanced magnetic transition temperatures, TC up to as high as 140 K, 40 K higher than that for standard BiMnO3 (BMO) films. Strong room temperature ferroelectricity with piezoresponse amplitude, d33 = 10 pm/V, and long-term retention of polarization were also observed. Furthermore, the BSMO films were much easier to grow than pure BMO films, with excellent phase purity over a wide growth window. The work represents a very effective way to independently control strain in-plane and out-of-plane, which is important not just for BMO but for controlling the properties of many other strongly correlated oxides. PMID:25141031

  3. Excessive sodium ions delivered into cells by nanodiamonds: implications for tumor therapy.

    PubMed

    Zhu, Ying; Li, Wenxin; Zhang, Yu; Li, Jing; Liang, Le; Zhang, Xiangzhi; Chen, Nan; Sun, Yanhong; Chen, Wen; Tai, Renzhong; Fan, Chunhai; Huang, Qing

    2012-06-11

    Nanodiamonds (NDs) possess many excellent physical and chemical properties that make them attractive materials for applications in biomedicine. In this paper, the adsorption and delivery of a large amount of sodium ions into the cell interior by NDs in serum-free medium is demonstrated. The excess sodium ions inside the cells induce osmotic stresses followed by cell swelling and an increase in the intracellular levels of calcium and reactive oxygen species (ROS), which leads to severe cellular damage. In complete culture medium, however, serum proteins wrapped around the NDs effectively prevent the sodium ions from adsorbing onto the NDs, and thus the NDs show no cytotoxicity. This work is the first to elaborate on the correlation between the sodium ions adsorbed on the nanomaterials and their bio-effects. Excessive ions delivered into cells by NDs might have potential applications in tumor therapy. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Structure-Function Relationships of Ferroelectric Polymers.

    NASA Astrophysics Data System (ADS)

    Pavlopoulou, Eleni; Maiz, Jon; Spampinato, Nicoletta; Maglione, Mario; Hadziioannou, Georges

    Poly(vinylidene fluoride), PVDF, and its copolymers with trifluoroethylene, P(VDF-co-TrFE) have been long appreciated for their excellent ferroelectric properties. Although they have been mainly studied in the 80s and 90s, understanding their performance is still lacking. Yet the increasing use of P(VDF-co-TrFE) thin films in organic electronic devices during the last ten years revives the need for apprehending the function of these materials. In this work we investigate the structure of P(VDF-co-TrFE) films and correlate it to their ferroelectric properties. Our results show that ferroelectric performance is solely driven by the fraction of polymer that has been crystallized in the ferroelectric phases of PVDF. The relations between remnant polarization, coercive field and dipole switching rate of P(VDF-co-TrFE) with the ferroelectric crystallinity are demonstrated. The French Research Agency (ANR), the Aquitaine Region, Arkema and STMicroelectronics are kindly acknowledged for financial support.

  5. Estimation of Koc values for deuterated benzene, toluene, and ethylbenzene, and application to ground water contamination studies.

    PubMed

    Poulson, S R; Drever, J I; Colberg, P J

    1997-11-01

    Sorption partition coefficients between water and organic carbon (Koc) for deuterated benzene, toluene, and ethylbenzene have been estimated by measuring values of the octanol-water partition coefficient (Kow) and HPLC retention factors (k1), which correlate closely to values of Koc. Measured values of log Kow for non-deuterated and deuterated toluene are 2.77 (+/- 0.02) and 2.78 (+/- 0.04), respectively, indicating that within experimental error, log Koc for deuterated and non-deuterated toluene are the same. The HPLC method provides greater precision, and yields values of delta log Koc (= log Koc [deuterated]-log Koc [non-deuterated]) of -0.021 (+/- 0.001) for benzene, -0.028 (+/- 0.002) for toluene, and -0.035 (+/- 0.003) for ethylbenzene. The small values of delta log Koc demonstrates that deuterated compounds are excellent tracers for the hydrologic behavior of ground water contaminants.

  6. UV-Vis absorption spectra and electronic structure of merocyanines in the gas phase

    NASA Astrophysics Data System (ADS)

    Ishchenko, Alexander A.; Kulinich, Andrii V.; Bondarev, Stanislav L.; Raichenok, Tamara F.

    2018-02-01

    Gas-phase absorption spectra of a merocyanine vinylogous series have been studied for the first time. In vapour, their long-wavelength absorption bands were found to be considerably shifted hypsochromically, broader, more symmetrical, less intense, and their vinylene shift much smaller than even in low-polarity n-hexane. This indicates that in the gas phase their electronic structure closely approaches the nonpolar polyene limiting structure. The TDDFT calculations of the long-wavelength electronic transitions in the studied merocyanines in vacuo demonstrated good-to-excellent correlation - depending on the functional used - with the obtained experimental data. For comparison, the solvent effects was accounted for using the polarizable continuum model (PCM) with n-hexane and ethanol as low-polarity and high-polarity media, and compared with the UV-Vis spectral data in these solvents. In this case, the discrepancy between theory and experiment was much greater, increasing at that with the polymethine chain length.

  7. Noninvasive Intracranial Volume and Pressure Measurements Using Ultrasound

    NASA Technical Reports Server (NTRS)

    Hargens, A. R.

    1998-01-01

    Prevention of secondary brain injuries following head can be accomplished most easily when intracranial pressure (ICP) is monitored. However, current measurement techniques are invasive and thus not practical in the combat environment. The Pulsed Phase Lock Loop (PPLL) devise, which was developed and patented, uses a unique, noninvasive ultrasonic phase comparison method to measure slight changes in cranial volume which occur with changes in ICP. Year one studies involved instrument improvements and measurement of altered intracranial distance with altered ICP in fresh cadavera. Our software was improved to facilitate future studies of normal subjects and trauma patients. Our bench studies proved that PPLL output correlated highly with changes in path length across a model cranium. Cadaveric studies demonstrated excellent compact, noninvasive devise for monitoring changes in intracranial distance may aid in the early detection of elevated ICP, decreasing risk of secondary brain injury and infection, and returning head-injured patients to duty.

  8. Characterization of Nightside Mid-latitude Irregularities Observed with the Blackstone SuperDARN Radar

    NASA Astrophysics Data System (ADS)

    Ruohoniemi, J. M.; Ribeiro, A. J.; Baker, J. B.; Greenwald, R. A.; Newell, P. T.

    2009-12-01

    The new mid-latitude SuperDARN radars at Wallops Island and Blackstone observe strong coherent backscattering on an almost nightly basis from latitudes that appear to be subauroral. One study has demonstrated an excellent correlation with the occurrence of density and temperature gradients within the ionospheric projection of the plasmapause (Greenwald et al., Geophys. Res. Lett. [2006]). We have processed all the data collected with the Blackstone radar since its inception in February 2008 for a characterization of the occurrence and properties of ‘plasmapause’ scatter. We have determined the local time and Kp dependencies of the activity and the relation of the spatial distribution of the irregularities to magnetospheric boundaries and ionospheric density gradients. We establish that the irregularities are a feature of the quiet-time subauroral ionosphere and provide a valuable diagnostic of the electric fields in the inner magnetosphere.

  9. Current Lewis Turbomachinery Research: Building on our Legacy of Excellence

    NASA Technical Reports Server (NTRS)

    Povinelli, Louis A.

    1997-01-01

    This Wu Chang-Hua lecture is concerned with the development of analysis and computational capability for turbomachinery flows which is based on detailed flow field physics. A brief review of the work of Professor Wu is presented as well as a summary of the current NASA aeropropulsion programs. Two major areas of research are described in order to determine our predictive capabilities using modern day computational tools evolved from the work of Professor Wu. In one of these areas, namely transonic rotor flow, it is demonstrated that a high level of accuracy is obtainable provided sufficient geometric detail is simulated. In the second case, namely turbine heat transfer, our capability is lacking for rotating blade rows and experimental correlations will provide needed information in the near term. It is believed that continuing progress will allow us to realize the full computational potential and its impact on design time and cost.

  10. Multi-fidelity machine learning models for accurate bandgap predictions of solids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pilania, Ghanshyam; Gubernatis, James E.; Lookman, Turab

    Here, we present a multi-fidelity co-kriging statistical learning framework that combines variable-fidelity quantum mechanical calculations of bandgaps to generate a machine-learned model that enables low-cost accurate predictions of the bandgaps at the highest fidelity level. Additionally, the adopted Gaussian process regression formulation allows us to predict the underlying uncertainties as a measure of our confidence in the predictions. In using a set of 600 elpasolite compounds as an example dataset and using semi-local and hybrid exchange correlation functionals within density functional theory as two levels of fidelities, we demonstrate the excellent learning performance of the method against actual high fidelitymore » quantum mechanical calculations of the bandgaps. The presented statistical learning method is not restricted to bandgaps or electronic structure methods and extends the utility of high throughput property predictions in a significant way.« less

  11. Flow, affect and visual creativity.

    PubMed

    Cseh, Genevieve M; Phillips, Louise H; Pearson, David G

    2015-01-01

    Flow (being in the zone) is purported to have positive consequences in terms of affect and performance; however, there is no empirical evidence about these links in visual creativity. Positive affect often--but inconsistently--facilitates creativity, and both may be linked to experiencing flow. This study aimed to determine relationships between these variables within visual creativity. Participants performed the creative mental synthesis task to simulate the creative process. Affect change (pre- vs. post-task) and flow were measured via questionnaires. The creativity of synthesis drawings was rated objectively and subjectively by judges. Findings empirically demonstrate that flow is related to affect improvement during visual creativity. Affect change was linked to productivity and self-rated creativity, but no other objective or subjective performance measures. Flow was unrelated to all external performance measures but was highly correlated with self-rated creativity; flow may therefore motivate perseverance towards eventual excellence rather than provide direct cognitive enhancement.

  12. Multi-fidelity machine learning models for accurate bandgap predictions of solids

    DOE PAGES

    Pilania, Ghanshyam; Gubernatis, James E.; Lookman, Turab

    2016-12-28

    Here, we present a multi-fidelity co-kriging statistical learning framework that combines variable-fidelity quantum mechanical calculations of bandgaps to generate a machine-learned model that enables low-cost accurate predictions of the bandgaps at the highest fidelity level. Additionally, the adopted Gaussian process regression formulation allows us to predict the underlying uncertainties as a measure of our confidence in the predictions. In using a set of 600 elpasolite compounds as an example dataset and using semi-local and hybrid exchange correlation functionals within density functional theory as two levels of fidelities, we demonstrate the excellent learning performance of the method against actual high fidelitymore » quantum mechanical calculations of the bandgaps. The presented statistical learning method is not restricted to bandgaps or electronic structure methods and extends the utility of high throughput property predictions in a significant way.« less

  13. Near-Infrared Ag2S Quantum Dots-Based DNA Logic Gate Platform for miRNA Diagnostics.

    PubMed

    Miao, Peng; Tang, Yuguo; Wang, Bidou; Meng, Fanyu

    2016-08-02

    Dysregulation of miRNA expression is correlated with the development and progression of many diseases. These miRNAs are regarded as promising biomarkers. However, it is challenging to measure these low abundant molecules without employing time-consuming radioactive labeling or complex amplification strategies. Here, we present a DNA logic gate platform for miRNA diagnostics with fluorescence outputs from near-infrared (NIR) Ag2S quantum dots (QDs). Carefully designed toehold exchange-mediated strand displacements with different miRNA inputs occur on a solid-state interface, which control QDs release from solid-state interface to solution, responding to multiplex information on initial miRNAs. Excellent fluorescence emission properties of NIR Ag2S QDs certify the great prospect for amplification-free and sensitive miRNA assay. We demonstrate the potential of this platform by achieving femtomolar level miRNA analysis and the versatility of a series of logic circuits computation.

  14. Open circuit potential monitored digital photocorrosion of GaAs/AlGaAs quantum well microstructures

    NASA Astrophysics Data System (ADS)

    Aithal, Srivatsa; Dubowski, Jan J.

    2018-04-01

    Nanostructuring of semiconductor wafers with an atomic level depth resolution is a challenging task, primarily due to the limited availability of instruments for in situ monitoring of such processes. Conventional digital etching relies on calibration procedures and cumbersome diagnostics applied between or at the end of etching cycles. We have developed a photoluminescence (PL) based process for monitoring in situ digital photocorrosion (DPC) of GaAs/AlGaAs microstructures at rates below 0.2 nm per cycle. In this communication, we demonstrate that DPC of GaAs/AlGaAs microstructures could be monitored with open circuit potential (OCP) measured between the photocorroding surface of a microstructure and an Ag/AgCl reference electrode installed in the sample chamber. The excellent correlation between the position of both PL and OCP maxima indicates that the DPC process could be monitored in situ for materials that do not necessarily exhibit measurable PL emission.

  15. Validation of a new physical activity questionnaire for a sedentary population.

    PubMed

    Rubenstein, Joel H; Morgenstern, Hal; Kellenberg, Joan; Kalish, Tal; Donovan, Jena; Inadomi, John; McConnell, Daniel; Stojanovska, Jadranka; Schoenfeld, Philip

    2011-09-01

    Many available physical activity questionnaires (PAQs) are limited due to either focus on recreational activities or burdensome length. We sought to assess the reliability and validity of a new short PAQ that captures all activity types. The 12-item multiple-choice PAQ-M included eight activity domains, providing a total Physical Activity Score (PAS-M) in kcal/kg/week. The new PAQ-M was administered with the previously validated Paffenbarger PAQ to 426 men, ages 50-79, undergoing colon-cancer screening. The PAQ-M had excellent test-retest reliability (intraclass correlation = 0.87). The PAS-M was moderately correlated with the Paffenbarger Physical Activity Score (PAS-P) (r = 0.31) and inversely correlated with BMI (r = -0.14) and waist circumference (r = -0.17). Adenoma prevalence was inversely associated with the PAS-M (3rd vs. 1st tertile adjusted odds ratio, 0.46; 95% confidence interval, 0.26-0.84) but not with the PAS-P. Our new short physical activity questionnaire has excellent test-retest reliability, and was correlated moderately with a widely used physical activity questionnaire and obesity measures. Furthermore, the new PAQ was a better predictor of adenoma prevalence in the expected direction than the Paffenbarger questionnaire in this largely sedentary population.

  16. Correlation between radiographic analysis of alveolar bone density around dental implant and resonance frequency of dental implant

    NASA Astrophysics Data System (ADS)

    Prawoko, S. S.; Nelwan, L. C.; Odang, R. W.; Kusdhany, L. S.

    2017-08-01

    The histomorphometric test is the gold standard for dental implant stability quantification; however, it is invasive, and therefore, it is inapplicable to clinical patients. Consequently, accurate and objective alternative methods are required. Resonance frequency analysis (RFA) and digital radiographic analysis are noninvasive methods with excellent objectivity and reproducibility. To analyze the correlation between the radiographic analysis of alveolar bone density around a dental implant and the resonance frequency of the dental implant. Digital radiographic images for 35 samples were obtained, and the resonance frequency of the dental implant was acquired using Osstell ISQ immediately after dental implant placement and on third-month follow-up. The alveolar bone density around the dental implant was subsequently analyzed using SIDEXIS-XG software. No significant correlation was reported between the alveolar bone density around the dental implant and the resonance frequency of the dental implant (r = -0.102 at baseline, r = 0.146 at follow-up, p > 0.05). However, the alveolar bone density and resonance frequency showed a significant difference throughout the healing period (p = 0.005 and p = 0.000, respectively). Conclusion: Digital dental radiographs and Osstell ISQ showed excellent objectivity and reproducibility in quantifying dental implant stability. Nonetheless, no significant correlation was observed between the results obtained using these two methods.

  17. Linear Least Squares for Correlated Data

    NASA Technical Reports Server (NTRS)

    Dean, Edwin B.

    1988-01-01

    Throughout the literature authors have consistently discussed the suspicion that regression results were less than satisfactory when the independent variables were correlated. Camm, Gulledge, and Womer, and Womer and Marcotte provide excellent applied examples of these concerns. Many authors have obtained partial solutions for this problem as discussed by Womer and Marcotte and Wonnacott and Wonnacott, which result in generalized least squares algorithms to solve restrictive cases. This paper presents a simple but relatively general multivariate method for obtaining linear least squares coefficients which are free of the statistical distortion created by correlated independent variables.

  18. Fully Automated Quantification of the Striatal Uptake Ratio of [99mTc]-TRODAT with SPECT Imaging: Evaluation of the Diagnostic Performance in Parkinson's Disease and the Temporal Regression of Striatal Tracer Uptake

    PubMed Central

    Fang, Yu-Hua Dean; Chiu, Shao-Chieh; Lu, Chin-Song; Weng, Yi-Hsin

    2015-01-01

    Purpose. We aimed at improving the existing methods for the fully automatic quantification of striatal uptake of [99mTc]-TRODAT with SPECT imaging. Procedures. A normal [99mTc]-TRODAT template was first formed based on 28 healthy controls. Images from PD patients (n = 365) and nPD subjects (28 healthy controls and 33 essential tremor patients) were spatially normalized to the normal template. We performed an inverse transform on the predefined striatal and reference volumes of interest (VOIs) and applied the transformed VOIs to the original image data to calculate the striatal-to-reference ratio (SRR). The diagnostic performance of the SRR was determined through receiver operating characteristic (ROC) analysis. Results. The SRR measured with our new and automatic method demonstrated excellent diagnostic performance with 92% sensitivity, 90% specificity, 92% accuracy, and an area under the curve (AUC) of 0.94. For the evaluation of the mean SRR and the clinical duration, a quadratic function fit the data with R 2 = 0.84. Conclusions. We developed and validated a fully automatic method for the quantification of the SRR in a large study sample. This method has an excellent diagnostic performance and exhibits a strong correlation between the mean SRR and the clinical duration in PD patients. PMID:26366413

  19. Fully Automated Quantification of the Striatal Uptake Ratio of [(99m)Tc]-TRODAT with SPECT Imaging: Evaluation of the Diagnostic Performance in Parkinson's Disease and the Temporal Regression of Striatal Tracer Uptake.

    PubMed

    Fang, Yu-Hua Dean; Chiu, Shao-Chieh; Lu, Chin-Song; Yen, Tzu-Chen; Weng, Yi-Hsin

    2015-01-01

    We aimed at improving the existing methods for the fully automatic quantification of striatal uptake of [(99m)Tc]-TRODAT with SPECT imaging. A normal [(99m)Tc]-TRODAT template was first formed based on 28 healthy controls. Images from PD patients (n = 365) and nPD subjects (28 healthy controls and 33 essential tremor patients) were spatially normalized to the normal template. We performed an inverse transform on the predefined striatal and reference volumes of interest (VOIs) and applied the transformed VOIs to the original image data to calculate the striatal-to-reference ratio (SRR). The diagnostic performance of the SRR was determined through receiver operating characteristic (ROC) analysis. The SRR measured with our new and automatic method demonstrated excellent diagnostic performance with 92% sensitivity, 90% specificity, 92% accuracy, and an area under the curve (AUC) of 0.94. For the evaluation of the mean SRR and the clinical duration, a quadratic function fit the data with R (2) = 0.84. We developed and validated a fully automatic method for the quantification of the SRR in a large study sample. This method has an excellent diagnostic performance and exhibits a strong correlation between the mean SRR and the clinical duration in PD patients.

  20. Rapid and sensitive detection of canine distemper virus by one-tube reverse transcription-insulated isothermal polymerase chain reaction.

    PubMed

    Wilkes, Rebecca P; Tsai, Yun-Long; Lee, Pei-Yu; Lee, Fu-Chun; Chang, Hsiao-Fen Grace; Wang, Hwa-Tang Thomas

    2014-09-09

    Canine distemper virus (CDV) has been associated with outbreaks of canine infectious respiratory disease in shelters and boarding kennel environments. POCKITTM Nucleic Acid Analyzer is a field-deployable device capable of generating automatically interpreted insulated isothermal polymerase chain reaction (iiPCR) results from extracted nucleic acid within one hour. In this study, reverse transcription iiPCR (RT-iiPCR) was developed to facilitate point-of-need diagnosis of CDV infection. Analytical sensitivity (limit of detection 95%) of the established CDV RT-iiPCR was about 11 copies of in vitro transcribed RNA per reaction. CDV RT-iiPCR generated positive signals from CDV, but not Bordetella bronchiseptica, canine parvovirus, canine herpesvirus, canine adenovirus 2, canine influenza virus (subtype H3N8), canine parainfluenza virus, and canine respiratory coronavirus. To evaluate accuracy of the established reaction in canine distemper clinical diagnosis, 110 specimens from dogs, raccoons, and foxes suspected with CDV infection were tested simultaneously by CDV RT-iiPCR and real-time RT-PCR. CDV RT-iiPCR demonstrated excellent sensitivity (100%) and specificity (100%), compared to real-time RT-PCR. The results indicated an excellent correlation between RT-iiPCR and a reference real time RT-PCR method. Working in a lyophilized format, the established method has great potential to be used for point-of-care diagnosis of canine distemper in animals, especially in resource-limited facilities.

  1. Quantitative Gait Measurement With Pulse-Doppler Radar for Passive In-Home Gait Assessment

    PubMed Central

    Skubic, Marjorie; Rantz, Marilyn; Cuddihy, Paul E.

    2014-01-01

    In this paper, we propose a pulse-Doppler radar system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed and step time using Doppler radar. The gait parameters have been validated with a Vicon motion capture system in the lab with 13 participants and 158 test runs. The study revealed that for an optimal step recognition and walking speed estimation, a dual radar set up with one radar placed at foot level and the other at torso level is necessary. An excellent absolute agreement with intraclass correlation coefficients of 0.97 was found for step time estimation with the foot level radar. For walking speed, although both radars show excellent consistency they all have a system offset compared to the ground truth due to walking direction with respect to the radar beam. The torso level radar has a better performance (9% offset on average) in the speed estimation compared to the foot level radar (13%–18% offset). Quantitative analysis has been performed to compute the angles causing the systematic error. These lab results demonstrate the capability of the system to be used as a daily gait assessment tool in home environments, useful for fall risk assessment and other health care applications. The system is currently being tested in an unstructured home environment. PMID:24771566

  2. Quantitative gait measurement with pulse-Doppler radar for passive in-home gait assessment.

    PubMed

    Wang, Fang; Skubic, Marjorie; Rantz, Marilyn; Cuddihy, Paul E

    2014-09-01

    In this paper, we propose a pulse-Doppler radar system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed and step time using Doppler radar. The gait parameters have been validated with a Vicon motion capture system in the lab with 13 participants and 158 test runs. The study revealed that for an optimal step recognition and walking speed estimation, a dual radar set up with one radar placed at foot level and the other at torso level is necessary. An excellent absolute agreement with intraclass correlation coefficients of 0.97 was found for step time estimation with the foot level radar. For walking speed, although both radars show excellent consistency they all have a system offset compared to the ground truth due to walking direction with respect to the radar beam. The torso level radar has a better performance (9% offset on average) in the speed estimation compared to the foot level radar (13%-18% offset). Quantitative analysis has been performed to compute the angles causing the systematic error. These lab results demonstrate the capability of the system to be used as a daily gait assessment tool in home environments, useful for fall risk assessment and other health care applications. The system is currently being tested in an unstructured home environment.

  3. Day to Day Variability and Reliability of Blood Oxidative Stress Markers within a Four-Week Period in Healthy Young Men.

    PubMed

    Goldfarb, A H; Garten, R S; Waller, J; Labban, J D

    2014-01-01

    The present study aimed to determine the day to day variability and reliability of several blood oxidative stress markers at rest in a healthy young cohort over a four-week period. Twelve apparently healthy resistance trained males (24.6 ± 3.0 yrs) were tested over 7 visits within 4 weeks with at least 72 hrs between visits at the same time of day. Subjects rested 30 minutes prior to blood being obtained by vacutainer. Results. The highest IntraClass correlations (ICC's) were obtained for protein carbonyls (PC) and oxygen radical absorbance capacity (ORAC) (PC = 0.785 and ORAC = 0.780). Cronbach's α reliability score for PC was 0.967 and for ORAC was 0.961. The ICC's for GSH, GSSG, and the GSSG/TGH ratio ICC were 0.600, 0.573, and 0.570, respectively, with Cronbach's α being 0.913, 0.904, and 0.903, respectively. Xanthine oxidase ICC was 0.163 and Cronbach's α was 0.538. Conclusions. PC and ORAC demonstrated good to excellent reliability while glutathione factors had poor to excellent reliability. Xanthine oxidase showed poor reliability and high variability. These results suggest that the PC and ORAC markers were the most stable and reliable oxidative stress markers in blood and that daily changes across visits should be considered when interpreting resting blood oxidative stress markers.

  4. Connecting the Force from Space: The IRIS Joint Capability Technology Demonstration

    DTIC Science & Technology

    2010-01-01

    the Joint in Joint Capability Technology Demonstration, we have two sponsors, both U.S. Strategic Command and the Defense Information Systems...Capability Technology Demonstration will provide an excellent source of data on space-based Internet Protocol net- working. Operational... Internet Routing in Space Joint Capability Technology Demonstration Operational Manager, Space and Missile Defense Battle Lab, Colorado Springs

  5. The Fresnel Zone Light Field Spectral Imager

    DTIC Science & Technology

    2017-03-23

    Marciniak Member AFIT-ENP-MS-17-M-095 Abstract This thesis provides a computational model and the first experimental demonstration of a Fresnel zone...Fresnel propagation. It was validated experimentally and provides excellent demonstration of system capabilities. The experimentally demonstrated system...in the measured light fields, they did not degrade the system’s performance. Experimental demonstration also showed the capability to resolve between

  6. First experimental demonstration of self-synchronous locking of optical coherence by single-detector electronic-frequency tagging of fiber amplifiers

    NASA Astrophysics Data System (ADS)

    Shay, T. M.; Benham, Vincent; Baker, J. T.; Ward, Benjamin; Sanchez, Anthony D.; Culpepper, Mark A.; Pilkington, D.; Spring, Justin; Nelson, Douglas J.; Lu, Chunte A.

    2006-08-01

    A novel high accuracy all electronic technique for phase locking arrays of optical fibers is demonstrated. We report the first demonstration of the only electronic phase locking technique that doesn't require a reference beam. The measured phase error is λ/20. Excellent phase locking has been demonstrated for fiber amplifier arrays.

  7. 3.0 Tesla breast magnetic resonance imaging in patients with nipple discharge when mammography and ultrasound fail.

    PubMed

    Lubina, Nóra; Schedelbeck, Ulla; Roth, Anne; Weng, Andreas Max; Geissinger, Eva; Hönig, Arnd; Hahn, Dietbert; Bley, Thorsten Alexander

    2015-05-01

    To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound, using 3.0 Tesla breast MRI with a dedicated 16-channel breast coil, and then compared the results with galactography. Histopathological diagnoses and follow-ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7 % vs. 85.7 % and 69.7 % vs. 33.3 %, respectively. For the supposed concrete pathology based on MRI findings, the specificity was 67.6 % and the sensitivity 77.3 % (PPV 60.7 %, NPV 82.1 %). Eight malignant lesions were detected (14.8 %). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson's correlation coefficient 0.95, p < 0.0001). MRI of the breast at 3.0 Tesla is an accurate imaging test and can replace galactography in the workup of nipple discharge in patients with inconspicuous mammography and ultrasound. • Breast MRI is an excellent diagnostic tool for patients with nipple discharge. • MRI of the breast reveals malignant lesions despite inconspicuous mammography and ultrasound. • MRI of the breast has greater sensitivity and specificity than galactography. • Excellent correlation of lesion size measured at MRI and histopathology was found.

  8. Room-temperature Pd-catalyzed C-H chlorination by weak coordination: one-pot synthesis of 2-chlorophenols with excellent regioselectivity.

    PubMed

    Sun, Xiuyun; Sun, Yonghui; Zhang, Chao; Rao, Yu

    2014-02-07

    A room-temperature Pd(II)-catalyzed regioselective chlorination reaction has been developed for a facile one-pot synthesis of a broad range of 2-chlorophenols. The reaction demonstrates an excellent regioselectivity and reactivity for C-H chlorination. This reaction represents one of the rare examples of mild C-H functionalization at ambient temperature.

  9. Discrimination of Apple Liqueurs (Nalewka) Using a Voltammetric Electronic Tongue, UV-Vis and Raman Spectroscopy

    PubMed Central

    Śliwińska, Magdalena; Garcia-Hernandez, Celia; Kościński, Mikołaj; Dymerski, Tomasz; Wardencki, Waldemar; Namieśnik, Jacek; Śliwińska-Bartkowiak, Małgorzata; Jurga, Stefan; Garcia-Cabezon, Cristina; Rodriguez-Mendez, Maria Luz

    2016-01-01

    The capability of a phthalocyanine-based voltammetric electronic tongue to analyze strong alcoholic beverages has been evaluated and compared with the performance of spectroscopic techniques coupled to chemometrics. Nalewka Polish liqueurs prepared from five apple varieties have been used as a model of strong liqueurs. Principal Component Analysis has demonstrated that the best discrimination between liqueurs prepared from different apple varieties is achieved using the e-tongue and UV-Vis spectroscopy. Raman spectra coupled to chemometrics have not been efficient in discriminating liqueurs. The calculated Euclidean distances and the k-Nearest Neighbors algorithm (kNN) confirmed these results. The main advantage of the e-tongue is that, using PLS-1, good correlations have been found simultaneously with the phenolic content measured by the Folin–Ciocalteu method (R2 of 0.97 in calibration and R2 of 0.93 in validation) and also with the density, a marker of the alcoholic content method (R2 of 0.93 in calibration and R2 of 0.88 in validation). UV-Vis coupled with chemometrics has shown good correlations only with the phenolic content (R2 of 0.99 in calibration and R2 of 0.99 in validation) but correlations with the alcoholic content were low. Raman coupled with chemometrics has shown good correlations only with density (R2 of 0.96 in calibration and R2 of 0.85 in validation). In summary, from the three holistic methods evaluated to analyze strong alcoholic liqueurs, the voltammetric electronic tongue using phthalocyanines as sensing elements is superior to Raman or UV-Vis techniques because it shows an excellent discrimination capability and remarkable correlations with both antioxidant capacity and alcoholic content—the most important parameters to be measured in this type of liqueurs.  PMID:27735832

  10. Discrimination of Apple Liqueurs (Nalewka) Using a Voltammetric Electronic Tongue, UV-Vis and Raman Spectroscopy.

    PubMed

    Śliwińska, Magdalena; Garcia-Hernandez, Celia; Kościński, Mikołaj; Dymerski, Tomasz; Wardencki, Waldemar; Namieśnik, Jacek; Śliwińska-Bartkowiak, Małgorzata; Jurga, Stefan; Garcia-Cabezon, Cristina; Rodriguez-Mendez, Maria Luz

    2016-10-09

    The capability of a phthalocyanine-based voltammetric electronic tongue to analyze strong alcoholic beverages has been evaluated and compared with the performance of spectroscopic techniques coupled to chemometrics. Nalewka Polish liqueurs prepared from five apple varieties have been used as a model of strong liqueurs. Principal Component Analysis has demonstrated that the best discrimination between liqueurs prepared from different apple varieties is achieved using the e-tongue and UV-Vis spectroscopy. Raman spectra coupled to chemometrics have not been efficient in discriminating liqueurs. The calculated Euclidean distances and the k-Nearest Neighbors algorithm (kNN) confirmed these results. The main advantage of the e-tongue is that, using PLS-1, good correlations have been found simultaneously with the phenolic content measured by the Folin-Ciocalteu method (R² of 0.97 in calibration and R² of 0.93 in validation) and also with the density, a marker of the alcoholic content method (R² of 0.93 in calibration and R² of 0.88 in validation). UV-Vis coupled with chemometrics has shown good correlations only with the phenolic content (R² of 0.99 in calibration and R² of 0.99 in validation) but correlations with the alcoholic content were low. Raman coupled with chemometrics has shown good correlations only with density (R² of 0.96 in calibration and R² of 0.85 in validation). In summary, from the three holistic methods evaluated to analyze strong alcoholic liqueurs, the voltammetric electronic tongue using phthalocyanines as sensing elements is superior to Raman or UV-Vis techniques because it shows an excellent discrimination capability and remarkable correlations with both antioxidant capacity and alcoholic content-the most important parameters to be measured in this type of liqueurs.

  11. Behavioral and cognitive outcomes for clinical trials in children with neurofibromatosis type 1.

    PubMed

    van der Vaart, Thijs; Rietman, André B; Plasschaert, Ellen; Legius, Eric; Elgersma, Ype; Moll, Henriëtte A

    2016-01-12

    To evaluate the appropriateness of cognitive and behavioral outcome measures in clinical trials in neurofibromatosis type 1 (NF1) by analyzing the degree of deficits compared to reference groups, test-retest reliability, and how scores correlate between outcome measures. Data were analyzed from the Simvastatin for cognitive deficits and behavioral problems in patients with neurofibromatosis type 1 (NF1-SIMCODA) trial, a randomized placebo-controlled trial of simvastatin for cognitive deficits and behavioral problems in children with NF1. Outcome measures were compared with age-specific reference groups to identify domains of dysfunction. Pearson r was computed for before and after measurements within the placebo group to assess test-retest reliability. Principal component analysis was used to identify the internal structure in the outcome data. Strongest mean score deviations from the reference groups were observed for full-scale intelligence (-1.1 SD), Rey Complex Figure Test delayed recall (-2.0 SD), attention problems (-1.2 SD), and social problems (-1.1 SD). Long-term test-retest reliability were excellent for Wechsler scales (r > 0.88), but poor to moderate for other neuropsychological tests (r range 0.52-0.81) and Child Behavioral Checklist subscales (r range 0.40-0.79). The correlation structure revealed 2 strong components in the outcome measures behavior and cognition, with no correlation between these components. Scores on psychosocial quality of life correlate strongly with behavioral problems and less with cognitive deficits. Children with NF1 show distinct deficits in multiple domains. Many outcome measures showed weak test-retest correlations over the 1-year trial period. Cognitive and behavioral outcomes are complementary. This analysis demonstrates the need to include reliable outcome measures on a variety of cognitive and behavioral domains in clinical trials for NF1. © 2015 American Academy of Neurology.

  12. Instrument validation process: a case study using the Paediatric Pain Knowledge and Attitudes Questionnaire.

    PubMed

    Peirce, Deborah; Brown, Janie; Corkish, Victoria; Lane, Marguerite; Wilson, Sally

    2016-06-01

    To compare two methods of calculating interrater agreement while determining content validity of the Paediatric Pain Knowledge and Attitudes Questionnaire for use with Australian nurses. Paediatric pain assessment and management documentation was found to be suboptimal revealing a need to assess paediatric nurses' knowledge and attitude to pain. The Paediatric Pain Knowledge and Attitudes Questionnaire was selected as it had been reported as valid and reliable in the United Kingdom with student nurses. The questionnaire required content validity determination prior to use in the Australian context. A two phase process of expert review. Ten paediatric nurses completed a relevancy rating of all 68 questionnaire items. In phase two, five pain experts reviewed the items of the questionnaire that scored an unacceptable item level content validity. Item and scale level content validity indices and intraclass correlation coefficients were calculated. In phase one, 31 items received an item level content validity index <0·78 and the scale level content validity index average was 0·80 which were below levels required for acceptable validity. The intraclass correlation coefficient was 0·47. In phase two, 10 items were amended and four items deleted. The revised questionnaire provided a scale level content validity index average >0·90 and an intraclass correlation coefficient of 0·94 demonstrating excellent agreement between raters therefore acceptable content validity. Equivalent outcomes were achieved using the content validity index and the intraclass correlation coefficient. To assess content validity the content validity index has the advantage of providing an item level score and is a simple calculation. The intraclass correlation coefficient requires statistical knowledge, or support, and has the advantage of accounting for the possibility of chance agreement. © 2016 John Wiley & Sons Ltd.

  13. Refinement of the Interprofessional Socialization and Valuing Scale (ISVS-21) and Development of 9-Item Equivalent Versions.

    PubMed

    King, Gillian; Orchard, Carole; Khalili, Hossein; Avery, Lisa

    2016-01-01

    Measures of interprofessional (IP) socialization are needed to capture the role of interprofessional education in preparing students and health practitioners to function as part of IP health care teams. The aims of this study were to refine a previously published version of the Interprofessional Socialization and Valuing Scale (the ISVS-24) and create two shorter equivalent forms to be used in pre-post studies. A graded response model was used to identify ISVS items in a practitioner data set (n = 345), with validation (measure invariance) conducted using a separate student sample (n = 341). Analyses indicated a unidimensional 21-item version with excellent measurement properties, Cronbach alpha of 0.988, 95% confidence interval (CI) 0.985-0.991. There was evidence of measure invariance, as there was excellent agreement of the factor scores for the practitioner and student data, intraclass correlation coefficient = 0.993, 95% CI 0.991-0.994. This indicates that the ISVS-21 measures IP socialization consistently across groups. Two 9-item equivalent versions for pre-post use were developed, with excellent agreement between the two forms. The student score agreement for the two item sets was excellent: intraclass correlation coefficient = 0.970, 95% CI 0.963-0.976. The ISVS-21 is a refined measure to assess existing levels of IP socialization in practitioners and students, and relate IP socialization to other important constructs such as IP collaboration and the development of an IP identity. The equivalent versions can be used to assess change in IP socialization as a result of interprofessional education.

  14. Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity

    PubMed Central

    Nicholas, Kevin; Sparkes, Valerie; Sheeran, Liba; Davies, Jennifer L

    2018-01-01

    The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 ± 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater) reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements. PMID:29495600

  15. Incidental Findings in Abdominal Dual-Energy Computed Tomography: Correlation Between True Noncontrast and Virtual Noncontrast Images Considering Renal and Liver Cysts and Adrenal Masses.

    PubMed

    Slebocki, Karin; Kraus, Bastian; Chang, De-Hua; Hellmich, Martin; Maintz, David; Bangard, Christopher

    To assess correlation between attenuation measurements of incidental findings in abdominal second generation dual-energy computed tomography (CT) on true noncontrast (TNC) and virtual noncontrast (VNC) images. Sixty-three patients underwent arterial dual-energy CT (Somatom Definition Flash, Siemens; pitch factor, 0.75-1.0; gantry rotation time, 0.28 seconds) after endovascular aneurysm repair, consisting of a TNC single energy CT scan (collimation, 128 × 0.6 mm; 120 kVp) and a dual-energy arterial phase scan (collimation, 32 × 0.6 mm, 140 and 100 kVp; blended, 120 kVp data set). Attenuation measurements in Hounsfield units (HU) of liver parenchyma and incidental findings like renal and hepatic cysts and adrenal masses on TNC and VNC images were done by drawing regions of interest. Statistical analysis was performed by paired t test and Pearson correlation. Incidental findings were detected in 56 (89%) patients. There was excellent correlation for both renal (n = 40) and hepatic cysts (n = 12) as well as adrenal masses (n = 6) with a Pearson correlation of 0.896, 0.800, and 0.945, respectively, and mean attenuation values on TNC and VNC images of 10.6 HU ± 12.8 versus 5.1 HU ± 17.5 (attenuation value range from -8.8 to 59.1 HU vs -11.8 to 73.4 HU), 6.4 HU ± 5.8 versus 6.3 HU ± 4.6 (attenuation value range from 2.0 to 16.2 HU vs -3.0 to 15.9 HU), and 12.8 HU ± 11.2 versus 12.4 HU ± 10.2 (attenuation value range from -2.3 to 27.5 HU vs -2.2 to 23.6 HU), respectively. As proof of principle, liver parenchyma measurements also showed excellent correlation between TNC and VNC (n = 40) images with a Pearson correlation of 0.839 and mean attenuation values on TNC and VNC images of 47.2 HU ± 10.5 versus 43.8 HU ± 8.7 (attenuation value range from 21.9 to 60.2 HU vs 4.5 to 65.3 HU). In conclusion, attenuation measurements of incidental findings like renal cysts or adrenal masses on TNC and VNC images derived from second generation dual-energy CT scans show excellent correlation providing considerable dose savings, favorable for future application in clinical routine.

  16. Estimation of health-related-quality of life depends on which utility measure is selected for patients with carpal tunnel syndrome.

    PubMed

    Nazari, Goris; MacDermid, Joy C; Bain, James; Levis, Carolyn M; Thoma, Achilleas

    Cross-sectional. Carpal tunnel syndrome (CTS) refers to the compression neuropathy of the median nerve at the wrist. To establish the interinstrument reliability, convergent construct validity, and the levels of agreement of health utility indexes 2 and 3 (HUI-2 and HUI-3), EuroQol 5-dimensions (EQ-5D), EuroQol-visual analog scale (EQ-VAS) and to determine the difference of these utility measures based on age and gender in patients with carpal tunnel syndrome. Seventy-four patients with a confirmed diagnosis of carpal tunnel syndrome completed the 3 questionnaires and EQ-VAS a month before surgery. Demographic characteristics were reported. Intraclass correlation coefficients were used to assess relative interinstrument reliability. Pearson correlation coefficients (r) were used to establish convergent construct validity. Bland-Altman plots and t tests were used to describe the levels of agreement between the 4 utility measures. A 2-way analysis of variance was performed to determine the effect of age and gender on the utility measures; HUI-2, HUI-3, and EQ-5D. The intraclass correlation coefficients were 0.85 for HUI-3 vs HUI-2 and 0.80 for HUI-2 vs EQ-VAS. Pearson correlation coefficients ranged from 0.60 to 0.89; HUI-3 vs HUI-2: 0.89, and HUI-3 vs EQ-5D: 0.60. One-sample t test demonstrated significant differences between HUI-3 vs HUI-2, HUI-3 vs EQ-5D, and HUI-3 vs EQ-VAS measures, with mean differences of -0.12, -0.15, and -0.14, respectively. A 2-way analysis of variance test controlling for age and gender indicated neither as predictors of outcome scores. The HUI-3 vs HUI-2 and HUI-2 vs EQ-VAS demonstrated excellent interinstrument relative reliability measures. The HUI-3 vs HUI-2 displayed very strong convergent construct validity measures, and strong validity measures were established between the remaining utility measures. In addition, the pair-wise utility comparisons demonstrated minimal bias between HUI-2 vs EQ-5D, HUI-2 vs EQ-VAS, and EQ-VAS vs EQ-5D measures. N/A. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  17. Glenoid deformity in the coronal plane correlates with humeral head changes in osteoarthritis: a radiographic analysis.

    PubMed

    Hawi, Nael; Magosch, Petra; Tauber, Mark; Lichtenberg, Sven; Martetschläger, Frank; Habermeyer, Peter

    2017-02-01

    A variety of measurements can be used to assess radiographic osteoarthritic changes of the shoulder. This study aimed to analyze the correlation between the radiographic humeral-sided Samilson and Prieto classification system and 3 different radiographic classifications describing the changes of the glenoid in the coronal plane. The study material included standardized radiographs of 50 patients with idiopathic osteoarthritis before anatomic shoulder replacement. On the basis of radiographic measurements, the cases were evaluated using the Samilson and Prieto grading system, angle β, inclination type, and critical shoulder angle by 2 independent observers. Classification measurements showed an excellent agreement between observers. Our results showed that the humeral-sided Samilson and Prieto grading system had a statistically significant good correlation with angle β (observer 1, r = 0.74; observer 2, r = 0.77; P < .05) and a statistically significant excellent correlation with the inclination type of the glenoid (observer 1, r  = 0.86; observer 2, r = 0.8; P < .05). A poor correlation to the critical shoulder angle was observed (r = -0.14, r = 0.03; P > .05). The grade of humeral-sided osteoarthritis according to Samilson and Prieto correlates with the glenoid-sided osteoarthritic changes of the glenoid in the coronal plane described by the angle β and by the inclination type of the glenoid. Higher glenoid-sided inclination is associated with higher grade of osteoarthritis in primary shoulder osteoarthritis. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Substituent Effects on Thermal Decolorization Rates of Bisbenzospiropyrans

    PubMed Central

    Lu, Nina T.; Nguyen, Vi N.; Kumar, Satish; McCurdy, Alison

    2009-01-01

    A novel application of photochromic molecules is to mimic physiological oscillatory calcium signals by reversibly binding and releasing calcium ions in response to light. Substituent changes on the largely unexplored photochromic bisbenzospiropyran scaffold led to significant changes in thermal fading rates in several organic solvents. Excellent correlations have been found between fading rates and empirical Hammett constants as well as calculated ground-state energies. These correlations can be used to improve scaffold design. PMID:16238356

  19. Measurement Properties of the Brief Michigan Hand Outcomes Questionnaire in Patients With Dupuytren Contracture.

    PubMed

    Wehrli, Martina; Hensler, Stefanie; Schindele, Stephan; Herren, Daniel B; Marks, Miriam

    2016-09-01

    The brief Michigan Hand Outcomes Questionnaire (briefMHQ) was developed as a shorter version of the Michigan Hand Outcomes Questionnaire (MHQ), but its measurement properties have not been investigated in patients with Dupuytren contracture. The objective of the study was to investigate the reliability, validity, responsiveness, and interpretability of the briefMHQ. Fifty-seven patients diagnosed with Dupuytren contracture completed the briefMHQ as well as the full-length MHQ and Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) questionnaire at baseline. Two to 14 days after baseline and 1 year after collagenase injection or surgery, patients again filled out the briefMHQ. Reliability was determined using the intraclass correlation coefficient and by calculating internal consistency (Cronbach alpha). Validity was tested by quantifying correlations with the full-length MHQ and QuickDASH. Responsiveness, based on the standardized response mean and the minimally clinically important change, was also determined. The briefMHQ had an intraclass correlation coefficient of 0.87, Cronbach alpha of 0.88, and correlations of r = 0.88 and -0.82 with the original MHQ and QuickDASH, respectively. The standardized response mean was 0.9 and the minimally clinically important change was 7 points. Overall, the briefMHQ demonstrates excellent reliability, good validity, and high responsiveness in patients with Dupuytren contracture. The briefMHQ is an accurate and time-saving tool to evaluate patients with Dupuytren contracture and the effect of a corresponding treatment. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Psychometric properties of the Positive and Negative Affect Schedule (PANAS) in a heterogeneous sample of substance users.

    PubMed

    Serafini, Kelly; Malin-Mayor, Bo; Nich, Charla; Hunkele, Karen; Carroll, Kathleen M

    2016-03-01

    The Positive and Negative Affect Schedule (PANAS) is a widely used measure of affect. A comprehensive psychometric evaluation among substance users, however, has not been published. To examine the psychometric properties of the PANAS in a sample of outpatient treatment substance users. We used pooled data from four randomized clinical trials (N = 416; 34% female, 48% African American). A confirmatory factor analysis indicated adequate support for a two-factor correlated model comprised of Positive Affect and Negative Affect with correlated item errors (Comparative Fit Index = 0.93, Root Mean Square Error of Approximation = 0.07, χ(2) = 478.93, df = 156). Cronbach's α indicated excellent internal consistency for both factors (0.90 and 0.91, respectively). The PANAS factors had good convergence and discriminability (Composite Reliability > 0.7; Maximum Shared Variance < Average Variance Extracted). A comparison from baseline to Week 1 indicated acceptable test-retest reliability (Positive Affect = 0.80, Negative Affect = 0.76). Concurrent and discriminant validity were demonstrated with correlations with the Brief Symptom Inventory and Addiction Severity Index. The PANAS scores were also significantly correlated with treatment outcomes (e.g. Positive Affect was associated with the maximum days of consecutive abstinence from primary substance of abuse, r = 0.16, p = 0.001). Our data suggest that the psychometric properties of the PANAS are retained in substance using populations. Although several studies have focused on the role of Negative Affect, our findings suggest that Positive Affect may also be an important factor in substance use treatment outcomes.

  1. Psychometric properties of the positive and negative affect schedule (PANAS) in a heterogeneous sample of substance users

    PubMed Central

    Serafini, Kelly; Malin-Mayor, Bo; Nich, Charla; Hunkele, Karen; Carroll, Kathleen M.

    2016-01-01

    Background The Positive and Negative Affect Schedule (PANAS) is a widely used measure of affect, and a comprehensive psychometric evaluation has never been conducted among substance users. Objective To examine the psychometric properties of the PANAS in a sample of outpatient treatment substance users. Methods We used pooled data from four randomized clinical trials (N = 416; 34% female, 48% African American). Results A confirmatory factor analysis indicated adequate support for a two-factor correlated model comprised of Positive Affect and Negative Affect with correlated item errors (Comparative Fit Index = .93, Root Mean Square Error of Approximation = .07, χ2 = 478.93, df = 156). Cronbach’s α indicated excellent internal consistency for both factors (.90 and .91, respectively). The PANAS factors had good convergence and discriminability (Composite Reliability >.7; Maximum Shared Variance < Average Variance Extracted). A comparison from baseline to Week 1 indicated acceptable test-retest reliability (Positive Affect = .80, Negative Affect = .76). Concurrent and discriminant validity were demonstrated with correlations with the Brief Symptom Inventory and Addiction Severity Index. The PANAS scores were also significantly correlated with treatment outcomes (e.g., Positive Affect was associated with the maximum days of consecutive abstinence from primary substance of abuse, r = .16, p = .001). Conclusion Our data suggest that the psychometric properties of the PANAS are retained in substance using populations. Although several studies have focused on the role of Negative Affect, our findings suggest that Positive Affect may also be an important factor in substance use treatment outcomes. PMID:26905228

  2. Professionalism in Medical Education

    ERIC Educational Resources Information Center

    Hilton, Sean; Southgate, Lesley

    2007-01-01

    Medical professionalism in today's society requires the exhibition of a range of qualities deployed in the service of patients, rather than more traditionally defined aspects such as mastery, autonomy and self-regulation. These qualities incorporate demonstrated clinical competence; aspiring to excellence in practice while demonstrating humility…

  3. Plain film measurement error in acute displaced midshaft clavicle fractures

    PubMed Central

    Archer, Lori Anne; Hunt, Stephen; Squire, Daniel; Moores, Carl; Stone, Craig; O’Dea, Frank; Furey, Andrew

    2016-01-01

    Background Clavicle fractures are common and optimal treatment remains controversial. Recent literature suggests operative fixation of acute displaced mid-shaft clavicle fractures (DMCFs) shortened more than 2 cm improves outcomes. We aimed to identify correlation between plain film and computed tomography (CT) measurement of displacement and the inter- and intraobserver reliability of repeated radiographic measurements. Methods We obtained radiographs and CT scans of patients with acute DMCFs. Three orthopedic staff and 3 residents measured radiographic displacement at time zero and 2 weeks later. The CT measurements identified absolute shortening in 3 dimensions (by subtracting the length of the fractured from the intact clavicle). We then compared shortening measured on radiographs and shortening measured in 3 dimensions on CT. Interobserver and intraobserver reliability were calculated. Results We reviewed the fractures of 22 patients. Bland–Altman repeatability coefficient calculations indicated that radiograph and CT measurements of shortening could not be correlated owing to an unacceptable amount of measurement error (6 cm). Interobserver reliability for plain radiograph measurements was excellent (Cronbach α = 0.90). Likewise, intraobserver reliabilities for plain radiograph measurements as calculated with paired t tests indicated excellent correlation (p > 0.05 in all but 1 observer [p = 0.04]). Conclusion To establish shortening as an indication for DMCF fixation, reliable measurement tools are required. The low correlation between plain film and CT measurements we observed suggests further research is necessary to establish what imaging modality reliably predicts shortening. Our results indicate weak correlation between radiograph and CT measurement of acute DMCF shortening. PMID:27438054

  4. Measuring the Cobb angle with the iPhone in kyphoses: a reliability study.

    PubMed

    Jacquot, Frederic; Charpentier, Axelle; Khelifi, Sofiane; Gastambide, Daniel; Rigal, Regis; Sautet, Alain

    2012-08-01

    Smartphones have gained widespread use in the healthcare field to fulfill a variety of tasks. We developed a small iPhone application to take advantage of the built-in position sensor to measure angles in a variety of spinal deformities. We present a reliability study of this tool in measuring kyphotic angles. Radiographs taken from 20 different patients' charts were presented to a panel of six operators at two different times. Radiographs were measured with the protractor and the iPhone application and statistical analysis was applied to measure intraclass correlation coefficients between both measurement methods, and to measure intra- and interobserver reliability The intraclass correlation coefficient calculated between methods (i.e. CobbMeter application on the iPhone versus standard method with the protractor) was 0.963 for all measures, indicating excellent correlation was obtained between the CobbMeter application and the standard method. The interobserver correlation coefficient was 0.965. The intraobserver ICC was 0.977, indicating excellent reproductibility of measurements at different times for all operators. The interobserver ICC between fellowship trained senior surgeons and general orthopaedic residents was 0.989. Consistently, the ICC for intraobserver and interobserver correlations was higher with the CobbMeter application than with the regular protractor method. This difference was not statistically significant. Measuring kyphotic angles with the iPhone application appears to be a valid procedure and is in no way inferior to the standard way of measuring the Cobb angle in kyphotic deformities.

  5. A simple program to measure and analyse tree rings using Excel, R and SigmaScan

    PubMed Central

    Hietz, Peter

    2011-01-01

    I present a new software that links a program for image analysis (SigmaScan), one for spreadsheets (Excel) and one for statistical analysis (R) for applications of tree-ring analysis. The first macro measures ring width marked by the user on scanned images, stores raw and detrended data in Excel and calculates the distance to the pith and inter-series correlations. A second macro measures darkness along a defined path to identify latewood–earlywood transition in conifers, and a third shows the potential for automatic detection of boundaries. Written in Visual Basic for Applications, the code makes use of the advantages of existing programs and is consequently very economic and relatively simple to adjust to the requirements of specific projects or to expand making use of already available code. PMID:26109835

  6. A simple program to measure and analyse tree rings using Excel, R and SigmaScan.

    PubMed

    Hietz, Peter

    I present a new software that links a program for image analysis (SigmaScan), one for spreadsheets (Excel) and one for statistical analysis (R) for applications of tree-ring analysis. The first macro measures ring width marked by the user on scanned images, stores raw and detrended data in Excel and calculates the distance to the pith and inter-series correlations. A second macro measures darkness along a defined path to identify latewood-earlywood transition in conifers, and a third shows the potential for automatic detection of boundaries. Written in Visual Basic for Applications, the code makes use of the advantages of existing programs and is consequently very economic and relatively simple to adjust to the requirements of specific projects or to expand making use of already available code.

  7. The Scarbase Duo(®): Intra-rater and inter-rater reliability and validity of a compact dual scar assessment tool.

    PubMed

    Fell, Matthew; Meirte, Jill; Anthonissen, Mieke; Maertens, Koen; Pleat, Jonathon; Moortgat, Peter

    2016-03-01

    Objective scar assessment tools were designed to help identify problematic scars and direct clinical management. Their use has been restricted by their measurement of a single scar property and the bulky size of equipment. The Scarbase Duo(®) was designed to assess both trans-epidermal water loss (TEWL) and colour of a burn scar whilst being compact and easy to use. Twenty patients with a burn scar were recruited and measurements taken using the Scarbase Duo(®) by two observers. The Scarbase Duo(®) measures TEWL via an open-chamber system and undertakes colorimetry via narrow-band spectrophotometry, producing values for relative erythema and melanin pigmentation. Validity was assessed by comparing the Scarbase Duo(®) against the Dermalab(®) and the Minolta Chromameter(®) respectively for TEWL and colorimetry measurements. The intra-class correlation coefficient (ICC) was used to assess reliability with standard error of measurement (SEM) used to assess reproducibility of measurements. The Pearson correlation coefficient (r) was used to assess the convergent validity. The Scarbase Duo(®) TEWL mode had excellent reliability when used on scars for both intra- (ICC=0.95) and inter-rater (ICC=0.96) measurements with moderate SEM values. The erythema component of the colorimetry mode showed good reliability for use on scars for both intra-(ICC=0.81) and inter-rater (ICC=0.83) measurements with low SEM values. Pigmentation values showed excellent reliability on scar tissue for both intra- (ICC=0.97) and inter-rater (ICC=0.97) with moderate SEM values. The Scarbase Duo(®) TEWL function had excellent correlation with the Dermalab(®) (r=0.93) whilst the colorimetry erythema value had moderate correlation with the Minolta Chromameter (r=0.72). The Scarbase Duo(®) is a reliable and objective scar assessment tool, which is specifically designed for burn scars. However, for clinical use, standardised measurement conditions are recommended. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  8. Cosmetic Outcomes and Quality of Life in Thai Women Post Breast Conserving Therapy for Breast Cancer.

    PubMed

    Thanarpan, Peerawong; Somrit, Mahattanobon; Rungarun, Jiratrachu; Paytai, Rordlamool; Duangjai, Sangtawan; Chanon, Kongkamol; Puttisak, Puttawibul

    2015-01-01

    To evaluate the correlation between cosmetic outcome (CO), body image, and quality of life in post breast-conserving therapy (BCT) women. This cross-sectional study concerned one-year post-completed BCT Thai women. The data included subjective and objective CO with a questionnaire covering demographic and clinical data, anti-hormonal treatment status, Eastern Cooperative Oncology Group (ECOG) performance status, Self-Reported Cosmetic Outcomes (SRCO), Self-Reported Breast Symmetry (SRBS), Body Image Scale (BIS), and the Functional Assessment of Cancer Therapy with Breast Cancer subscale (FACT-B). Participants had breast photographs taken for the evaluation of objective cosmetic outcome (OCO) after breast cancer conservation treatment. The relationship between CO and FACT-B was tested using Spearman's rank correlation Results: A total 127 participants volunteered for the study. The participant characteristics were age 52(±9), Buddhist 87%, married 65%, body mass index 25.0(±4.6), breast cup size A-C 91%, college educated 60%, employed 66%, ECOG 0-1 95%, tumor size less than or equal to 2 cm 55%, no lymph node metastasis 98%, and taking tamoxifen 57%. Two percent of the participants regretted their decision to undergo BCT. The SRCO was excellent in 2%, good in 68%, fair in 30%, and poor in 0%. For SRBS, rates were 17%, 58%, 24% and 1% for excellent, good, fair and poor cosmetic outcomes, respectively. The BCCT scores were excellent 24%, good 39%, fair 32%, and poor 6%. The median total QOL score of the participants was 130 (93-144). There was no significant correlation between CO and FACT-B scores. The significance of CO for FACT-B in Thai women with breast cancer could not be assessed in detail because of a very low level of correlation. The results may be due to the effects of cultural background.

  9. Data acquisition and real-time control using spreadsheets: interfacing Excel with external hardware.

    PubMed

    Aliane, Nourdine

    2010-07-01

    Spreadsheets have become a popular computational tool and a powerful platform for performing engineering calculations. Moreover, spreadsheets include a macro language, which permits the inclusion of standard computer code in worksheets, and thereby enable developers to greatly extend spreadsheets' capabilities by designing specific add-ins. This paper describes how to use Excel spreadsheets in conjunction to Visual Basic for Application programming language to perform data acquisition and real-time control. Afterwards, the paper presents two Excel applications with interactive user interfaces developed for laboratory demonstrations and experiments in an introductory course in control. 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Bumps on the road to Magnet designation: achieving organizational excellence.

    PubMed

    Steinbinder, Amy

    2009-01-01

    The chief nursing officer is in a unique position to guide his or her organization to excellence by creating a compelling vision; maintaining objectivity regarding the nursing department's accomplishments; holding senior nurse leaders accountable as Magnet champions; demonstrating strategic thinking, business planning development, operational connection, and awareness of clinical aspects of care; and establishing levels of ownership and decision making within the nursing department's operational framework. The clear definition of terms including responsibility, authority, delegation, accountability, and empowerment are necessary and, coupled with specific actions, skills, and measures of success, guide individual and group processes to achieve organizational excellence and ultimately Magnet designation.

  11. Rapid Synthesis of Carbon Dots by Hydrothermal Treatment of Lignin

    PubMed Central

    Chen, Wenxin; Hu, Chaofan; Yang, Yunhua; Cui, Jianghu; Liu, Yingliang

    2016-01-01

    A rapid approach has been developed for the fluorescent carbon dots (CDs) by the hydrothermal treatment of lignin in the presence of H2O2. The as-synthesized CDs were found to emit blue photoluminescence with excellent photostability. Moreover, the CDs displayed biocompatibility, low cytotoxicity, and high water solubility properties. Finally, the as-resulted CDs were demonstrated to be excellent probes for bioimaging and biosensing applications. PMID:28773309

  12. Validating the shortened Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55) in a sample of children with drug-resistant epilepsy.

    PubMed

    Conway, Lauryn; Widjaja, Elysa; Smith, Mary Lou; Speechley, Kathy N; Ferro, Mark A

    2017-04-01

    The aim of this study was to validate the newly developed shortened Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55) in a sample of children with drug-resistant epilepsy. Data came from 136 children enrolled in the Impact of Pediatric Epilepsy Surgery on Health-Related Quality of Life Study (PEPSQOL), a multicenter prospective cohort study. Confirmatory factor analysis was used to assess the higher-order factor structure of the QOLCE-55. Convergent and divergent validity was assessed by correlating subscales of the KIDSCREEN-27 with the QOLCE-55. Measurement equivalence of the QOLCE-55 was evaluated using multiple-group confirmatory factor analysis of children with drug-resistant epilepsy from PEPSQOL versus children with new-onset epilepsy from HERQULES (Health-Related Quality of Life in Children with Epilepsy Study). The higher-order factor structure of the QOLCE-55 demonstrated adequate fit: Comparative Fit Index (CFI) = 0.948; Tucker-Lewis Index (TLI) = 0.946; Root Mean Square of Approximation (RMSEA) = 0.060 (90% confidence interval [CI] 0.054-0.065); Weighted Root Mean Square Residuals (WRMR) = 1.247. Higher-order factor loadings were strong, ranging from λ = 0.74 to 0.81. Internal consistency reliability was excellent (α = 0.97, subscales α > 0.82). QOLCE-55 subscales demonstrated moderate to strong correlations with similar subscales of the KIDSCREEN-27 (ρ = 0.43-0.75) and weak to moderate correlations with dissimilar subscales (ρ = 0.25-0.42). The QOLCE-55 demonstrated partial measurement equivalence at the level of strict invariance - χ 2 (2,823) = 3,727.9, CFI = 0.961, TLI = 0.962, RMSEA = 0.049 (0.044, 0.053), WRMR = 1.834. The findings provide support for the factor structure of the QOLCE-55 and contribute to its robust psychometric profile as a reliable and valid measure. Researchers and health practitioners should consider the QOLCE-55 as a viable option for reducing respondent burden when assessing health-related quality of life in children with epilepsy. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  13. Preparation of fluorescent mesoporous hollow silica-fullerene nanoparticles via selective etching for combined chemotherapy and photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Yang, Yannan; Yu, Meihua; Song, Hao; Wang, Yue; Yu, Chengzhong

    2015-07-01

    Well-dispersed mesoporous hollow silica-fullerene nanoparticles with particle sizes of ~50 nm have been successfully prepared by incorporating fullerene molecules into the silica framework followed by a selective etching method. The fabricated fluorescent silica-fullerene composite with high porosity demonstrates excellent performance in combined chemo/photodynamic therapy.Well-dispersed mesoporous hollow silica-fullerene nanoparticles with particle sizes of ~50 nm have been successfully prepared by incorporating fullerene molecules into the silica framework followed by a selective etching method. The fabricated fluorescent silica-fullerene composite with high porosity demonstrates excellent performance in combined chemo/photodynamic therapy. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr02769a

  14. The HOLO Series: Critical Ground-Based Demonstrations of Holographic Scanning Lidars

    NASA Technical Reports Server (NTRS)

    Wilkerson, Thomas D.; Sanders, Jason A.; Andrus, Ionio Q.; Schwemmer, Geary K.; Miller, David O.; Guerra, David; Schnick, Jeffrey; Moody, Stephen E.

    2000-01-01

    Results of two lidar measurement campaigns are presented, HOLO-1 (Utah, March 1999) and HOLO-2 (New Hampshire, June 1999). These tests demonstrate the ability of lidars utilizing holographic optical elements (HOEs) to determine tropospheric wind velocity and direction at cloud altitude. Several instruments were employed. HOLO-1 used the 1,064 mm transmission-HOE lidar (HARLIE, Goddard Space Flight Center), a zenith-staring 532 nm lidar (AROL-2, Utah State University), and a wide-field video camera (SkyCam) for imagery of clouds overhead. HOLO-2 included these instruments plus the 532 nm reflection-HOE lidar (PHASERS, St. Anselm College). HARLIE and PHASERS scan the sky at constant cone angles of 45 deg. and 42 deg. from normal, respectively. The progress of clouds and entire cloud fields across the sky is tracked by the repetitive conical scans of the HOE lidars. AROL-2 provides the attitude information enabling the SkyCam cloud images to be analyzed for independent data on cloud motion. Data from the HOE lidars are reduced by means of correlations, visualization by animation techniques, and kinematic diagrams of cloud feature motion. Excellent agreement is observed between the HOE lidar results and those obtained with video imagery and lidar ranging.

  15. Psychometric properties of the communication Confidence Rating Scale for Aphasia (CCRSA): phase 1.

    PubMed

    Cherney, Leora R; Babbitt, Edna M; Semik, Patrick; Heinemann, Allen W

    2011-01-01

    Confidence is a construct that has not been explored previously in aphasia research. We developed the Communication Confidence Rating Scale for Aphasia (CCRSA) to assess confidence in communicating in a variety of activities and evaluated its psychometric properties using rating scale (Rasch) analysis. The CCRSA was administered to 21 individuals with aphasia before and after participation in a computer-based language therapy study. Person reliability of the 8-item CCRSA was .77. The 5-category rating scale demonstrated monotonic increases in average measures from low to high ratings. However, one item ("I follow news, sports, stories on TV/movies") misfit the construct defined by the other items (mean square infit = 1.69, item-measure correlation = .41). Deleting this item improved reliability to .79; the 7 remaining items demonstrated excellent fit to the underlying construct, although there was a modest ceiling effect in this sample. Pre- to posttreatment changes on the 7-item CCRSA measure were statistically significant using a paired samples t test. Findings support the reliability and sensitivity of the CCRSA in assessing participants' self-report of communication confidence. Further evaluation of communication confidence is required with larger and more diverse samples.

  16. Issues in cross-cultural validity: example from the adaptation, reliability, and validity testing of a Turkish version of the Stanford Health Assessment Questionnaire.

    PubMed

    Küçükdeveci, Ayse A; Sahin, Hülya; Ataman, Sebnem; Griffiths, Bridget; Tennant, Alan

    2004-02-15

    Guidelines have been established for cross-cultural adaptation of outcome measures. However, invariance across cultures must also be demonstrated through analysis of Differential Item Functioning (DIF). This is tested in the context of a Turkish adaptation of the Health Assessment Questionnaire (HAQ). Internal construct validity of the adapted HAQ is assessed by Rasch analysis; reliability, by internal consistency and the intraclass correlation coefficient; external construct validity, by association with impairments and American College of Rheumatology functional stages. Cross-cultural validity is tested through DIF by comparison with data from the UK version of the HAQ. The adapted version of the HAQ demonstrated good internal construct validity through fit of the data to the Rasch model (mean item fit 0.205; SD 0.998). Reliability was excellent (alpha = 0.97) and external construct validity was confirmed by expected associations. DIF for culture was found in only 1 item. Cross-cultural validity was found to be sufficient for use in international studies between the UK and Turkey. Future adaptation of instruments should include analysis of DIF at the field testing stage in the adaptation process.

  17. Interdisciplinary evaluation of dysphagia: clinical swallowing evaluation and videoendoscopy of swallowing.

    PubMed

    Sordi, Marina de; Mourão, Lucia Figueiredo; Silva, Ariovaldo Armando da; Flosi, Luciana Claudia Leite

    2009-01-01

    Patients with dysphagia have impairments in many aspects, and an interdisciplinary approach is fundamental to define diagnosis and treatment. A joint approach in the clinical and videoendoscopy evaluation is paramount. To study the correlation between the clinical assessment (ACD) and the videoendoscopic (VED) assessment of swallowing by classifying the degree of severity and the qualitative/descriptive analyses of the procedures. cross-sectional, descriptive and comparative. held from March to December of 2006, at the Otolaryngology/Dysphagia ward of a hospital in the country side of São Paulo. 30 dysphagic patients with different disorders were assessed by ACD and VED. The data was classified by means of severity scales and qualitative/ descriptive analysis. the correlation between severity ACD and VED scales pointed to a statistically significant low agreement (KAPA = 0.4) (p=0,006). The correlation between the qualitative/descriptive analysis pointed to an excellent and statistically significant agreement (KAPA=0.962) (p<0.001) concerning the entire sample. the low agreement between the severity scales point to a need to perform both procedures, reinforcing VED as a doable procedure. The descriptive qualitative analysis pointed to an excellent agreement, and such data reinforces our need to understand swallowing as a process.

  18. Comparison of Three Real-Time Measurement Methods for Airborne Ultrafine Particles in the Silicon Alloy Industry.

    PubMed

    Kero, Ida Teresia; Jørgensen, Rikke Bramming

    2016-09-01

    The aim of this study was to compare the applicability and the correlation between three commercially available instruments capable of detection, quantification, and characterization of ultrafine airborne particulate matter in the industrial setting of a tapping area in a silicon alloy production plant. The number concentration of ultrafine particles was evaluated using an Electric Low Pressure Impactor (ELPI(TM)), a Fast Mobility Particle Sizer (FMPS(TM)), and a Condensation Particle Counter (CPC). The results are discussed in terms of particle size distribution and temporal variations linked to process operations. The instruments show excellent temporal covariation and the correlation between the FMPS and ELPI is good. The advantage of the FMPS is the excellent time- and size resolution of the results. The main advantage of the ELPI is the possibility to collect size-fractionated samples of the dust for subsequent analysis by, for example, electron microscopy. The CPC does not provide information about the particle size distribution and its correlation to the other two instruments is somewhat poor. Nonetheless, the CPC gives basic, real-time information about the ultrafine particle concentration and can therefore be used for source identification.

  19. Comparison of Three Real-Time Measurement Methods for Airborne Ultrafine Particles in the Silicon Alloy Industry

    PubMed Central

    Kero, Ida Teresia; Jørgensen, Rikke Bramming

    2016-01-01

    The aim of this study was to compare the applicability and the correlation between three commercially available instruments capable of detection, quantification, and characterization of ultrafine airborne particulate matter in the industrial setting of a tapping area in a silicon alloy production plant. The number concentration of ultrafine particles was evaluated using an Electric Low Pressure Impactor (ELPITM), a Fast Mobility Particle Sizer (FMPSTM), and a Condensation Particle Counter (CPC). The results are discussed in terms of particle size distribution and temporal variations linked to process operations. The instruments show excellent temporal covariation and the correlation between the FMPS and ELPI is good. The advantage of the FMPS is the excellent time- and size resolution of the results. The main advantage of the ELPI is the possibility to collect size-fractionated samples of the dust for subsequent analysis by, for example, electron microscopy. The CPC does not provide information about the particle size distribution and its correlation to the other two instruments is somewhat poor. Nonetheless, the CPC gives basic, real-time information about the ultrafine particle concentration and can therefore be used for source identification. PMID:27598180

  20. In situ probing of the active site geometry of ultrathin nanowires for the oxygen reduction reaction

    DOE PAGES

    Liu, Haiqing; Wong, Stanislaus S.; An, Wei; ...

    2015-09-24

    To create truly effective electrocatalysts for the cathodic reaction governing proton exchange membrane fuel cells (PEMFC), namely the oxygen reduction reaction (ORR), necessitates an accurate and detailed structural understanding of these electrocatalysts, especially at the nanoscale, and to precisely correlate that structure with demonstrable performance enhancement. To address this key issue, we have combined and interwoven theoretical calculations with experimental, spectroscopic observations in order to acquire useful structural insights into the active site geometry with implications for designing optimized nanoscale electrocatalysts with rationally predicted properties. Specifically, we have probed ultrathin (~2 nm) core–shell Pt~Pd 9Au nanowires, which have been previouslymore » shown to be excellent candidates for ORR in terms of both activity and long-term stability, from the complementary perspectives of both DFT calculations and X-ray absorption spectroscopy (XAS). The combination and correlation of data from both experimental and theoretical studies has revealed for the first time that the catalytically active structure of our ternary nanowires can actually be ascribed to a PtAu~Pd configuration, comprising a PtAu binary shell and a pure inner Pd core. Moreover, we have plausibly attributed the resulting structure to a specific synthesis step, namely the Cu underpotential deposition (UPD) followed by galvanic replacement with Pt. Thus, the fundamental insights gained into the performance of our ultrathin nanowires from our demonstrated approach will likely guide future directed efforts aimed at broadly improving upon the durability and stability of nanoscale electrocatalysts in general.« less

  1. Assessing educational outcomes in middle childhood: validation of the Teacher Academic Attainment Scale.

    PubMed

    Johnson, Samantha; Marlow, Neil; Wolke, Dieter

    2012-06-01

    Assessing educational outcomes in high-risk populations is crucial for defining long-term outcomes. As standardized tests are costly and time-consuming, we assessed the use of the Teacher Academic Attainment Scale (TAAS) as an outcome measure. Three hundred and forty three children in mainstream schools aged 10 to 11 years (144 males, 199 females; 190 extremely preterm and 153 term; mean age 10 y 9 mo, SD 5.5 mo, range 9 y 8 mo-12 y 3 mo) were assessed using the reading and mathematics scales of the criterion standard Wechsler Individual Achievement Test, 2nd (UK) edition (WIAT-II). Class teachers completed the TAAS, a seven-item questionnaire for assessing academic attainment. The TAAS was also completed at 6 years of age for 266 children. Cronbach's alpha 0.95 indicated excellent internal consistency, and the correlation between TAAS scores at 6 and 11 years indicated good test-retest reliability (r=0.77, p<0.001). Significantly higher TAAS scores for term vs preterm children demonstrated discriminative validity. TAAS scores at 6 and 11 years were significantly correlated with WIAT-II reading (r=0.69 and 0.75, p<0.001) and mathematics (r=0.75 and 0.82, p<0.001) scores, demonstrating good predictive and concurrent validity respectively. TAAS scores of <2.5 were good predictors of learning difficulties. The TAAS is a brief, psychometrically sound teacher-report of academic attainment that yields continuous and categorical outcomes. It provides a cost- and time-efficient outcome measure for large-scale studies. © The Authors. Developmental Medicine & Child Neurology © 2012 Mac Keith Press.

  2. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    PubMed

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  3. Eph A10-modified pH-sensitive liposomes loaded with novel triphenylphosphine-docetaxel conjugate possess hierarchical targetability and sufficient antitumor effect both in vitro and in vivo.

    PubMed

    Zhang, Jiulong; Yang, Chunrong; Pan, Shuang; Shi, Menghao; Li, Jie; Hu, Haiyang; Qiao, Mingxi; Chen, Dawei; Zhao, Xiuli

    2018-11-01

    Mitochondrial-targeting therapy was considered to be a promising approach for the efficient treatment of cancer while positive charge induced nonspecific cytotoxicity severely limits its application. To overcome this drawback, a novel mitochondria targeted conjugate triphenylphosphine-docetaxel (TD) has been synthesized successfully and incorporated it into liposomes (EPSLP/TD), which possessed excellent pH-sensitive characteristic, EphA 10 mediated active targetability as well as mitochondria-targeting capability. EPSLP/TD was characterized to have a small particle size, high-encapsulation efficiency and excellent pH-sensitive characteristic. Compared with DTX-loaded liposomes (EPSLP/DTX), EPSLP/TD possessed higher cytotoxicity against MCF-7 cell line. Mitochondrial-targeting assay demonstrated mitochondria-targeting moiety triphenylphosphine (TPP) could efficiently deliver DTX to mitochondria. Western immunoblotting assay indicated that EPSLP/TD could efficiently deliver antitumor drug to mitochondria and induce cell apoptosis via mitochondria-mediated apoptosis pathway. In vivo antitumor study demonstrated EPSLP/TD owed excellent in vivo antitumor activity. Histological assay demonstrated EPSLP/TD showed strongly apoptosis inducing effect, anti-proliferation effect and anti-angiogenesis effect. This work investigated the potential of hierarchical targeting pH-sensitive liposomes is a suitable carrier to activate mitochondria-mediated apoptosis pathway for cancer therapy.

  4. Repeatability of shear wave elastography in liver fibrosis phantoms—Evaluation of five different systems

    PubMed Central

    2018-01-01

    This study aimed to assess and validate the repeatability and agreement of quantitative elastography of novel shear wave methods on four individual tissue-mimicking liver fibrosis phantoms with different known Young’s modulus. We used GE Logiq E9 2D-SWE, Philips iU22 ARFI (pSWE), Samsung TS80A SWE (pSWE), Hitachi Ascendus (SWM) and Transient Elastography (TE). Two individual investigators performed all measurements non-continued and in parallel. The methods were evaluated for inter- and intraobserver variability by intraclass correlation, coefficient of variation and limits of agreement using the median elastography value. All systems used in this study provided high repeatability in quantitative measurements in a liver fibrosis phantom and excellent inter- and intraclass correlations. All four elastography platforms showed excellent intra-and interobserver agreement (interclass correlation 0.981–1.000 and intraclass correlation 0.987–1.000) and no significant difference in mean elasticity measurements for all systems, except for TE on phantom 4. All four liver fibrosis phantoms could be differentiated by quantitative elastography, by all platforms (p<0.001). In the Bland-Altman analysis the differences in measurements were larger for the phantoms with higher Young’s modulus. All platforms had a coefficient of variation in the range 0.00–0.21 for all four phantoms, equivalent to low variance and high repeatability. PMID:29293527

  5. Validation of the Parental-Caregiver Perceptions Questionnaire: agreement between parental and child reports.

    PubMed

    Barbosa, Taís de Souza; Gavião, Maria Beatriz Duarte

    2015-01-01

    To test the validity and reliability of Brazilian Portuguese version of the Parental-Caregiver Perceptions Questionnaire (P-CPQ) (Aim 1) and to assess the agreement between parents and children concerning the child's oral health-related quality of life (OHRQoL) (Aim 2). The P-CPQ and the Brazilian Portuguese versions of the Child Perceptions Questionnaires (CPQ8-10 and CPQ11-14 ) were used. Objective 1 addressed in the study that involved 210 (validity and internal reliability) and 20 (test-retest reliability) parents and Objective 2 in the study that involved 210 pairs of parents and children. Construct validity was calculated using the Spearman's correlation and the Mann-Whitney/Kruskal-Wallis tests. Reliability was determined using Cronbach's alpha and intraclass correlation coefficient (ICC). Agreement between overall and subscale scores derived from the P-CPQ and CPQ was assessed in comparison and correlation analyses. The P-CPQ discriminated among the categories of malocclusion and dmft. The P-CPQ showed good construct validity, good internal consistency reliability, and excellent test-retest reliability. There was systematic under- and overreporting in parents' assessments for younger and older children, respectively. However, the magnitude of the directional differences was just small. At individual level, agreement between parents and children was excellent. However, it ranged from excellent to moderate or substantial in subscales for CPQ8-10 and CPQ11-14 groups, respectively. The Portuguese version of P-CPQ is valid and reliable. Some parents have limited knowledge about child OHRQoL. Given that parental and child reports measure different realities concerning the child's OHRQoL, information provided by parents can complement the child's evaluation. © 2015 American Association of Public Health Dentistry.

  6. PedsQL™ Eosinophilic Esophagitis Module: Feasibility, Reliability and Validity

    PubMed Central

    Franciosi, James P.; Hommel, Kevin A.; Bendo, Cristiane B.; King, Eileen C.; Collins, Margaret H.; Eby, Michael D.; Marsolo, Keith; Abonia, J. Pablo; von Tiehl, Karl F.; Putnam, Philip E.; Greenler, Alexandria J.; Greenberg, Allison B.; Bryson, Ronald A.; Davis, Carla M.; Olive, Anthony P.; Gupta, Sandeep K.; Erwin, Elizabeth A.; Klinnert, Mary D.; Spergel, Jonathan M.; Denham, Jolanda M.; Furuta, Glenn T.; Rothenberg, Marc E.; Varni, James W.

    2014-01-01

    Objective Eosinophilic esophagitis (EoE) is a chronic esophageal inflammatory condition with a paucity of information on health-related quality of life (HRQOL). The objective of the study was to report on the measurement properties of the PedsQL™ EoE Module. Methods The PedsQL™ EoE Module was completed in a multisite study by 196 pediatric EoE patients and 262 EoE parents. Results The PedsQL™ EoE Module scales evidenced excellent feasibility (0.6%–3.1% missing), excellent group comparison reliability across total scale scores (patient α = 0.93; parent proxy α = 0.94), good reliability for the seven individual scales (patient α = 0.75–0.87; parent proxy α = 0.81–0.92), excellent test-retest reliability (patient ICC = 0.88; parent ICC= 0.82), demonstrated no floor effects and low ceiling effects, and demonstrated a high percentage of scaling success for most scales. Intercorrelations with the PedsQL™ Generic Core Scales were in the medium (0.30) to large (0.50) range. PedsQL™ EoE Module scores were worse among patients with active histologic disease (> 5 eos/hpf) compared to those in remission (patient self-report: 63.3 vs. 69.9 [p<0.05]; parent proxy-report: 65.1 vs. 72.3 [p<0.01]), and those treated with dietary restrictions compared to those with no restrictions (patient self-report: 61.6 vs. 74.3 [p< 0.01]; parent proxy-report: 65.5 vs. 74.7 [p<0.01]). Conclusions The results demonstrate excellent measurement properties of the PedsQL™ EoE Module. Patients with active histologic disease and those treated with dietary restrictions demonstrated worse PedsQL™ scores. The PedsQL™ EoE Module may be utilized in evaluation of pediatric EoE disease-specific HRQOL in clinical research and practice. PMID:23478422

  7. Rhodium(II)-catalyzed enantioselective synthesis of troponoids.

    PubMed

    Murarka, Sandip; Jia, Zhi-Jun; Merten, Christian; Daniliuc, Constantin-G; Antonchick, Andrey P; Waldmann, Herbert

    2015-06-22

    We report a rhodium(II)-catalyzed highly enantioselective 1,3-dipolar cycloaddition reaction between the carbonyl moiety of tropone and carbonyl ylides to afford troponoids in good to high yields with excellent enantioselectivity. We demonstrate that α-diazoketone-derived carbonyl ylides, in contrast to carbonyl ylides derived from diazodiketoesters, undergo [6+3] cycloaddition reactions with tropone to yield the corresponding bridged heterocycles with excellent stereoselectivity. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Reliability study of tibialis posterior and selected leg muscle EMG and multi-segment foot kinematics in rheumatoid arthritis associated pes planovalgus

    PubMed Central

    Barn, Ruth; Rafferty, Daniel; Turner, Deborah E.; Woodburn, James

    2012-01-01

    Objective To determine within- and between-day reliability characteristics of electromyographic (EMG) activity patterns of selected lower leg muscles and kinematic variables in patients with rheumatoid arthritis (RA) and pes planovalgus. Methods Five patients with RA underwent gait analysis barefoot and shod on two occasions 1 week apart. Fine-wire (tibialis posterior [TP]) and surface EMG for selected muscles and 3D kinematics using a multi-segmented foot model was undertaken barefoot and shod. Reliability of pre-determined variables including EMG activity patterns and inter-segment kinematics were analysed using coefficients of multiple correlation, intraclass correlation coefficients (ICC) and the standard error of the measurement (SEM). Results Muscle activation patterns within- and between-day ranged from fair-to-good to excellent in both conditions. Discrete temporal and amplitude variables were highly variable across all muscle groups in both conditions but particularly poor for TP and peroneus longus. SEMs ranged from 1% to 9% of stance and 4% to 27% of maximum voluntary contraction; in most cases the 95% confidence interval crossed zero. Excellent within-day reliability was found for the inter-segment kinematics in both conditions. Between-day reliability ranged from fair-to-good to excellent for kinematic variables and all ICCs were excellent; the SEM ranged from 0.60° to 1.99°. Conclusion Multi-segmented foot kinematics can be reliably measured in RA patients with pes planovalgus. Serial measurement of discrete variables for TP and other selected leg muscles via EMG is not supported from the findings in this cohort of RA patients. Caution should be exercised when EMG measurements are considered to study disease progression or intervention effects. PMID:22721819

  9. Ego-Dissolution and Psychedelics: Validation of the Ego-Dissolution Inventory (EDI)

    PubMed Central

    Nour, Matthew M.; Evans, Lisa; Nutt, David; Carhart-Harris, Robin L.

    2016-01-01

    Aims: The experience of a compromised sense of “self”, termed ego-dissolution, is a key feature of the psychedelic experience. This study aimed to validate the Ego-Dissolution Inventory (EDI), a new 8-item self-report scale designed to measure ego-dissolution. Additionally, we aimed to investigate the specificity of the relationship between psychedelics and ego-dissolution. Method: Sixteen items relating to altered ego-consciousness were included in an internet questionnaire; eight relating to the experience of ego-dissolution (comprising the EDI), and eight relating to the antithetical experience of increased self-assuredness, termed ego-inflation. Items were rated using a visual analog scale. Participants answered the questionnaire for experiences with classical psychedelic drugs, cocaine and/or alcohol. They also answered the seven questions from the Mystical Experiences Questionnaire (MEQ) relating to the experience of unity with one’s surroundings. Results: Six hundred and ninety-one participants completed the questionnaire, providing data for 1828 drug experiences (1043 psychedelics, 377 cocaine, 408 alcohol). Exploratory factor analysis demonstrated that the eight EDI items loaded exclusively onto a single common factor, which was orthogonal to a second factor comprised of the items relating to ego-inflation (rho = −0.110), demonstrating discriminant validity. The EDI correlated strongly with the MEQ-derived measure of unitive experience (rho = 0.735), demonstrating convergent validity. EDI internal consistency was excellent (Cronbach’s alpha 0.93). Three analyses confirmed the specificity of ego-dissolution for experiences occasioned by psychedelic drugs. Firstly, EDI score correlated with drug-dose for psychedelic drugs (rho = 0.371), but not for cocaine (rho = 0.115) or alcohol (rho = −0.055). Secondly, the linear regression line relating the subjective intensity of the experience to ego-dissolution was significantly steeper for psychedelics (unstandardized regression coefficient = 0.701) compared with cocaine (0.135) or alcohol (0.144). Ego-inflation, by contrast, was specifically associated with cocaine experiences. Finally, a binary Support Vector Machine classifier identified experiences occasioned by psychedelic drugs vs. cocaine or alcohol with over 85% accuracy using ratings of ego-dissolution and ego-inflation alone. Conclusion: Our results demonstrate the psychometric structure, internal consistency and construct validity of the EDI. Moreover, we demonstrate the close relationship between ego-dissolution and the psychedelic experience. The EDI will facilitate the study of the neuronal correlates of ego-dissolution, which is relevant for psychedelic-assisted psychotherapy and our understanding of psychosis. PMID:27378878

  10. [Development of a Text-Data Based Learning Tool That Integrates Image Processing and Displaying].

    PubMed

    Shinohara, Hiroyuki; Hashimoto, Takeyuki

    2015-01-01

    We developed a text-data based learning tool that integrates image processing and displaying by Excel. Knowledge required for programing this tool is limited to using absolute, relative, and composite cell references and learning approximately 20 mathematical functions available in Excel. The new tool is capable of resolution translation, geometric transformation, spatial-filter processing, Radon transform, Fourier transform, convolutions, correlations, deconvolutions, wavelet transform, mutual information, and simulation of proton density-, T1-, and T2-weighted MR images. The processed images of 128 x 128 pixels or 256 x 256 pixels are observed directly within Excel worksheets without using any particular image display software. The results of image processing using this tool were compared with those using C language and the new tool was judged to have sufficient accuracy to be practically useful. The images displayed on Excel worksheets were compared with images using binary-data display software. This comparison indicated that the image quality of the Excel worksheets was nearly equal to the latter in visual impressions. Since image processing is performed by using text-data, the process is visible and facilitates making contrasts by using mathematical equations within the program. We concluded that the newly developed tool is adequate as a computer-assisted learning tool for use in medical image processing.

  11. A Simple Index for the High-Citation Tail of Citation Distribution to Quantify Research Performance in Countries and Institutions

    PubMed Central

    Rodríguez-Navarro, Alonso

    2011-01-01

    Background Conventional scientometric predictors of research performance such as the number of papers, citations, and papers in the top 1% of highly cited papers cannot be validated in terms of the number of Nobel Prize achievements across countries and institutions. The purpose of this paper is to find a bibliometric indicator that correlates with the number of Nobel Prize achievements. Methodology/Principal Findings This study assumes that the high-citation tail of citation distribution holds most of the information about high scientific performance. Here I propose the x-index, which is calculated from the number of national articles in the top 1% and 0.1% of highly cited papers and has a subtractive term to discount highly cited papers that are not scientific breakthroughs. The x-index, the number of Nobel Prize achievements, and the number of national articles in Nature or Science are highly correlated. The high correlations among these independent parameters demonstrate that they are good measures of high scientific performance because scientific excellence is their only common characteristic. However, the x-index has superior features as compared to the other two parameters. Nobel Prize achievements are low frequency events and their number is an imprecise indicator, which in addition is zero in most institutions; the evaluation of research making use of the number of publications in prestigious journals is not advised. Conclusion The x-index is a simple and precise indicator for high research performance. PMID:21647383

  12. A simple index for the high-citation tail of citation distribution to quantify research performance in countries and institutions.

    PubMed

    Rodríguez-Navarro, Alonso

    2011-01-01

    Conventional scientometric predictors of research performance such as the number of papers, citations, and papers in the top 1% of highly cited papers cannot be validated in terms of the number of Nobel Prize achievements across countries and institutions. The purpose of this paper is to find a bibliometric indicator that correlates with the number of Nobel Prize achievements. This study assumes that the high-citation tail of citation distribution holds most of the information about high scientific performance. Here I propose the x-index, which is calculated from the number of national articles in the top 1% and 0.1% of highly cited papers and has a subtractive term to discount highly cited papers that are not scientific breakthroughs. The x-index, the number of Nobel Prize achievements, and the number of national articles in Nature or Science are highly correlated. The high correlations among these independent parameters demonstrate that they are good measures of high scientific performance because scientific excellence is their only common characteristic. However, the x-index has superior features as compared to the other two parameters. Nobel Prize achievements are low frequency events and their number is an imprecise indicator, which in addition is zero in most institutions; the evaluation of research making use of the number of publications in prestigious journals is not advised. The x-index is a simple and precise indicator for high research performance.

  13. Freiburg Questionnaire of linguistic pragmatics (FQLP): psychometric properties based on a psychiatric sample.

    PubMed

    Riedel, Andreas; Suh, Heejung; Haser, Verena; Hermann, Ismene; Ebert, Dieter; Riemann, Dieter; Bubl, Emanuel; Tebartz van Elst, Ludger; Hölzel, Lars P

    2014-12-24

    Asperger's Syndrome (AS) is an autism spectrum disorder that is characterized by significant difficulties in social interaction and nonverbal communication, and restricted and repetitive patterns of behavior and interests. Difficulties with respect to pragmatic speech, reading emotional and social cues, differentiating between fact and fiction, and taking into account the influence of context on a statement are commonly described features. However, hitherto established questionnaires did not focus on these symptoms. In this study we present a short (11 questions) questionnaire which focuses on self-rated pragmatic speech abilities, the Freiburg Questionnaire of linguistic pragmatics (FQLP). Psychometric properties of the questionnaire were explored in a sample of 57 patients with Asperger's Syndrome, 66 patients with other psychiatric disorders, and a convenience sample of 56 people. Reliability analysis showed a high Cronbach's α. Strong correlations could be demonstrated for the FQLP with the Autism Quotient and the Empathy Quotient. Concerning divergent validity a moderate correlation was found between the FQLP and self-rated symptoms of personality disorders. No significant correlation was found between the FQLP and the vocabulary skills. The receiver operating characteristics curve showed an excellent diagnostic accuracy of the FQLP (.97). As the control group consisted of people without mental disorder and patients with different psychiatric disorders, the results indicate that the construct examined by the FQLP is quite specific to the peculiarities of AS. The FQLP is a reliable, brief and valid instrument. First results regarding sensitivity and specificity are highly promising.

  14. Selected reaction monitoring (SRM) mass spectrometry without isotope labeling can be used for rapid protein quantification

    PubMed Central

    Zhi, Wenbo; Wang, Meiyao

    2014-01-01

    The validation of putative biomarker candidates has become the major bottle-neck in protein biomarker development. Conventional immunoaffinity methods are limited by the availability of antibodies and kits. Here we demonstrated the feasibility of using the selected reaction monitoring (SRM) without isotope labeling to achieve fast and reproducible quantification of serum proteins. The SRM/MRM assays for three standard serum proteins, including ceruloplasmin (CP), serum aymloid A (SAA) and sex hormone binding globulin (SHBG) have good linear ranges, generally 103 – 104. There are almost perfect correlations between SRM intensities and the loaded peptide amounts (R2 is usually ~0.99). Our data suggest that SRM/MRM is able to quantify proteins at 0.2 – 2 fmol level, which are comparable to the commercial ELISA/LUMINEX kits for these proteins. Excellent correlations between SRM/MRM and ELISA/LUMINEX assays were observed for SAA and SHBG (R2 = 0.928 and 0.851 respectively). The correlation between SRM/MRM and ELISA for CP is less desirable (R2 = 0.565). The reproducibility for SRM/MRM assays is generally very good but may depend on the proteins/peptides (R2 = 0.931 and 0.882 for SAA and SHBG, and 0.723 for CP). SRM/MRM assay without isotope labeling is a rapid and useful method for protein biomarker validation in a modest number of samples and is especially useful when other assays such as ELISA or Luminex beads are not available. PMID:21594933

  15. Determination of Soil Moisture Content using Laboratory Experimental and Field Electrical Resistivity Values

    NASA Astrophysics Data System (ADS)

    Hazreek, Z. A. M.; Rosli, S.; Fauziah, A.; Wijeyesekera, D. C.; Ashraf, M. I. M.; Faizal, T. B. M.; Kamarudin, A. F.; Rais, Y.; Dan, M. F. Md; Azhar, A. T. S.; Hafiz, Z. M.

    2018-04-01

    The efficiency of civil engineering structure require comprehensive geotechnical data obtained from site investigation. In the past, conventional site investigation was heavily related to drilling techniques thus suffer from several limitations such as time consuming, expensive and limited data collection. Consequently, this study presents determination of soil moisture content using laboratory experimental and field electrical resistivity values (ERV). Field and laboratory electrical resistivity (ER) test were performed using ABEM SAS4000 and Nilsson400 soil resistance meter. Soil sample used for resistivity test was tested for characterization test specifically on particle size distribution and moisture content test according to BS1377 (1990). Field ER data was processed using RES2DINV software while laboratory ER data was analyzed using SPSS and Excel software. Correlation of ERV and moisture content shows some medium relationship due to its r = 0.506. Moreover, coefficient of determination, R2 analyzed has demonstrate that the statistical correlation obtain was very good due to its R2 value of 0.9382. In order to determine soil moisture content based on statistical correlation (w = 110.68ρ-0.347), correction factor, C was established through laboratory and field ERV given as 19.27. Finally, this study has shown that soil basic geotechnical properties with particular reference to water content was applicably determined using integration of laboratory and field ERV data analysis thus able to compliment conventional approach due to its economic, fast and wider data coverage.

  16. The validity of proxy-based data on loneliness in suicide research: a case-control psychological autopsy study in rural China.

    PubMed

    Niu, Lu; Jia, Cunxian; Ma, Zhenyu; Wang, Guojun; Yu, Zhenjun; Zhou, Liang

    2018-05-01

    There is a lack of evidence for the role of loneliness on suicide using psychological autopsy method, and the validity of proxy informants' reports on loneliness is not well established. This study aimed to investigate the validity of proxy respondent reports on loneliness, and the reliability and validity of the University of California Los Angeles Loneliness Scale-6 (ULS-6) as used in psychological autopsy method with rural elderly people in China. Two hundred forty-two suicide cases and 242 normal community controls were selected, and the psychological autopsy method was utilized to collect information. Data from proxy respondents of the living controls were compared with data reported by the targets (gold standards). Subject-proxy concordance for ULS-6 was fair (ICC = 0.447) in the living controls. The suicide cases were more likely to have a higher score of ULS-6 than the living controls. Additionally, our data supported that ULS-6 had adequate psychometric properties in both suicide and control groups: factor analyses yielded one-factor component solution; Cronbach's alpha (both > 0.90) demonstrated excellent internal consistency; the Spearman correlation analysis indicated that the ULS-6 score was positively correlated with depression; and negatively correlated with QOL and social support. Results support proxy-based data on loneliness in research of suicide in older adults in rural China, and the ULS-6 is a psychometrically sound instrument for measuring loneliness in psychological autopsy studies.

  17. Towards a subcutaneous optical biosensor based on thermally hydrocarbonised porous silicon.

    PubMed

    Tong, Wing Yin; Sweetman, Martin J; Marzouk, Ezzat R; Fraser, Cara; Kuchel, Tim; Voelcker, Nicolas H

    2016-01-01

    Advanced biosensors in future medicine hinge on the evolvement of biomaterials. Porous silicon (pSi), a generally biodegradable and biocompatible material that can be fabricated to include environment-responsive optical characteristics, is an excellent candidate for in vivo biosensors. However, the feasibility of using this material as a subcutaneously implanted optical biosensor has never been demonstrated. Here, we investigated the stability and biocompatibility of a thermally-hydrocarbonised (THC) pSi optical rugate filter, and demonstrated its optical functionality in vitro and in vivo. We first compared pSi films with different surface chemistries and observed that the material was cytotoxic despite the outstanding stability of the THC pSi films. We then showed that the cytotoxicity correlates with reactive oxygen species levels, which could be mitigated by pre-incubation of THC pSi (PITHC pSi). PITHC pSi facilitates normal cellular phenotypes and is biocompatible in vivo. Importantly, the material also possesses optical properties capable of responding to microenvironmental changes that are readable non-invasively in cell culture and subcutaneous settings. Collectively, we demonstrate, for the first time, that PITHC pSi rugate filters are both biocompatible and optically functional for lab-on-a-chip and subcutaneous biosensing scenarios. We believe that this study will deepen our understanding of cell-pSi interactions and foster the development of implantable biosensors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Teach up for Excellence

    ERIC Educational Resources Information Center

    Tomlinson, Carol Ann; Javius, Edwin Lou

    2012-01-01

    Sorting students into different tracks within a school correlates strongly with student race and economic status and predicts and contributes to student outcomes. Students in higher-level classes typically experience better teachers, curriculum, and achievement levels than peers in lower-level classes. Creating classrooms that support equity of…

  19. Simulation of 100-300 GHz solid-state harmonic sources

    NASA Technical Reports Server (NTRS)

    Zybura, Michael F.; Jones, J. Robert; Jones, Stephen H.; Tait, Gregory B.

    1995-01-01

    Accurate and efficient simulations of the large-signal time-dependent characteristics of second-harmonic Transferred Electron Oscillators (TEO's) and Heterostructure Barrier Varactor (HBV) frequency triplers have been obtained. This is accomplished by using a novel and efficient harmonic-balance circuit analysis technique which facilitates the integration of physics-based hydrodynamic device simulators. The integrated hydrodynamic device/harmonic-balance circuit simulators allow TEO and HBV circuits to be co-designed from both a device and a circuit point of view. Comparisons have been made with published experimental data for both TEO's and HBV's. For TEO's, excellent correlation has been obtained at 140 GHz and 188 GHz in second-harmonic operation. Excellent correlation has also been obtained for HBV frequency triplers operating near 200 GHz. For HBV's, both a lumped quasi-static equivalent circuit model and the hydrodynamic device simulator have been linked to the harmonic-balance circuit simulator. This comparison illustrates the importance of representing active devices with physics-based numerical device models rather than analytical device models.

  20. The capability of lithography simulation based on MVM-SEM® system

    NASA Astrophysics Data System (ADS)

    Yoshikawa, Shingo; Fujii, Nobuaki; Kanno, Koichi; Imai, Hidemichi; Hayano, Katsuya; Miyashita, Hiroyuki; Shida, Soichi; Murakawa, Tsutomu; Kuribara, Masayuki; Matsumoto, Jun; Nakamura, Takayuki; Matsushita, Shohei; Hara, Daisuke; Pang, Linyong

    2015-10-01

    The 1Xnm technology node lithography is using SMO-ILT, NTD or more complex pattern. Therefore in mask defect inspection, defect verification becomes more difficult because many nuisance defects are detected in aggressive mask feature. One key Technology of mask manufacture is defect verification to use aerial image simulator or other printability simulation. AIMS™ Technology is excellent correlation for the wafer and standards tool for defect verification however it is difficult for verification over hundred numbers or more. We reported capability of defect verification based on lithography simulation with a SEM system that architecture and software is excellent correlation for simple line and space.[1] In this paper, we use a SEM system for the next generation combined with a lithography simulation tool for SMO-ILT, NTD and other complex pattern lithography. Furthermore we will use three dimension (3D) lithography simulation based on Multi Vision Metrology SEM system. Finally, we will confirm the performance of the 2D and 3D lithography simulation based on SEM system for a photomask verification.

  1. The concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis.

    PubMed

    Quek, June; Brauer, Sandra G; Treleaven, Julia; Clark, Ross A

    2017-09-01

    This study aims to investigate the concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis against the Flexicurve. Thirty-three healthy individuals (age: 31±11.0 years, men: 17, height: 170.2±8.2 cm, weight: 64.2±12.0 kg) participated, with 29 re-examined for intrarater reliability 1-7 days later. Thoracic kyphosis was measured using the Flexicurve and the Microsoft Kinect consecutively in both standing and sitting positions. Both the kyphosis index and angle were calculated. The Microsoft Kinect showed excellent concurrent validity (intraclass correlation coefficient=0.76-0.82) and reliability (intraclass correlation coefficient=0.81-0.98) for measuring thoracic kyphosis (angle and index) in both standing and sitting postures. This study is the first to show that the Microsoft Kinect has excellent validity and intrarater reliability to measure thoracic kyphosis, which is promising for its use in the clinical setting.

  2. imDEV: a graphical user interface to R multivariate analysis tools in Microsoft Excel.

    PubMed

    Grapov, Dmitry; Newman, John W

    2012-09-01

    Interactive modules for Data Exploration and Visualization (imDEV) is a Microsoft Excel spreadsheet embedded application providing an integrated environment for the analysis of omics data through a user-friendly interface. Individual modules enables interactive and dynamic analyses of large data by interfacing R's multivariate statistics and highly customizable visualizations with the spreadsheet environment, aiding robust inferences and generating information-rich data visualizations. This tool provides access to multiple comparisons with false discovery correction, hierarchical clustering, principal and independent component analyses, partial least squares regression and discriminant analysis, through an intuitive interface for creating high-quality two- and a three-dimensional visualizations including scatter plot matrices, distribution plots, dendrograms, heat maps, biplots, trellis biplots and correlation networks. Freely available for download at http://sourceforge.net/projects/imdev/. Implemented in R and VBA and supported by Microsoft Excel (2003, 2007 and 2010).

  3. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    PubMed

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, p<0.001) and 4MGS (r=-0.583, p=0.003). This study demonstrates excellent inter-observer and test-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Evaluating trauma team performance in a Level I trauma center: Validation of the trauma team communication assessment (TTCA-24).

    PubMed

    DeMoor, Stephanie; Abdel-Rehim, Shady; Olmsted, Richard; Myers, John G; Parker-Raley, Jessica

    2017-07-01

    Nontechnical skills (NTS), such as team communication, are well-recognized determinants of trauma team performance and good patient care. Measuring these competencies during trauma resuscitations is essential, yet few valid and reliable tools are available. We aimed to demonstrate that the Trauma Team Communication Assessment (TTCA-24) is a valid and reliable instrument that measures communication effectiveness during activations. Two tools with adequate psychometric strength (Trauma Nontechnical Skills Scale [T-NOTECHS], Team Emergency Assessment Measure [TEAM]) were identified during a systematic review of medical literature and compared with TTCA-24. Three coders used each tool to evaluate 35 stable and 35 unstable patient activations (defined according to Advanced Trauma Life Support criteria). Interrater reliability was calculated between coders using the intraclass correlation coefficient. Spearman rank correlation coefficient was used to establish concurrent validity between TTCA-24 and the other two validated tools. Coders achieved an intraclass correlation coefficient of 0.87 for stable patient activations and 0.78 for unstable activations scoring excellent on the interrater agreement guidelines. The median score for each assessment showed good team communication for all 70 videos (TEAM, 39.8 of 54; T-NOTECHS, 17.4 of 25; and TTCA-24, 87.4 of 96). A significant correlation between TTTC-24 and T-NOTECHS was revealed (p = 0.029), but no significant correlation between TTCA-24 and TEAM (p = 0.77). Team communication was rated slightly better across all assessments for stable versus unstable patient activations, but not statistically significant. TTCA-24 correlated with T-NOTECHS, an instrument measuring nontechnical skills for trauma teams, but not TEAM, a tool that assesses communication in generic emergency settings. TTCA-24 is a reliable and valid assessment that can be a useful adjunct when evaluating interpersonal and team communication during trauma activations. Diagnostic tests or criteria, level II.

  5. Triggered Urine Interleukin-6 Correlates to Severity of Symptoms in Nonfebrile Lower Urinary Tract Infections.

    PubMed

    Sundén, Fredrik; Butler, Daniel; Wullt, Björn

    2017-07-01

    Objective diagnosis of symptomatic urinary tract infections in patients prone to asymptomatic bacteriuria is compromised by local host responses that are already present and the positive urine culture. We investigated interleukin-6 as a biomarker for nonfebrile urinary tract infection severity and diagnostic thresholds for interleukin-6 and 8, and neutrophils to differentiate between asymptomatic bacteriuria and urinary tract infection. Patients with residual urine and neurogenic bladders due to spinal lesions included in a long-term Escherichia coli 83972 asymptomatic bacteriuria inoculation trial were monitored for 2 years. Symptom scoring and urine sampling to estimate interleukin-6 and 8, and neutrophils were performed regularly monthly and at urinary tract infection episodes. Patients were followed in the complete study for a mean of 19 months (range 10 to 27) and those with asymptomatic bacteriuria with E. coli 83972 were followed a mean of 11 months (range 4 to 19). A total of 37 nonfebrile urinary tract infection episodes with complete data on interleukin-6 and 8, neutrophils and symptom scoring were documented. Interleukin-6 was the only marker that persistently increased during urinary tract infection compared to asymptomatic bacteriuria in pooled and paired intra-individual comparisons (p <0.05). Interleukin-6 above the threshold (greater than 25 ng/l) correlated to more severe urinary tract infection symptoms (p <0.05). The sensitivity and specificity of all biomarkers were poor/moderate when differentiating asymptomatic bacteriuria vs all urinary tract infection episodes. However, in urinary tract infections with worse symptoms interleukin-6 and neutrophils demonstrated equal good/excellent outcomes. Triggered interleukin-6 correlated to urinary tract infection symptom severity and demonstrated a promising differential diagnostic capacity to discriminate urinary tract infection from asymptomatic bacteriuria. Future studies should explore interleukin-6 as a biomarker of urinary tract infection severity and assess the treatment indication in nonfebrile urinary tract infections. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. A preliminary examination of the validity and reliability of a new brief rating scale for symptom domains of psychosis: Brief Evaluation of Psychosis Symptom Domains (BE-PSD).

    PubMed

    Takeuchi, Hiroyoshi; Fervaha, Gagan; Lee, Jimmy; Agid, Ofer; Remington, Gary

    2016-09-01

    Brief assessments have the potential to be widely adopted as outcome measures in research but also routine clinical practice. Existing brief rating scales that assess symptoms of schizophrenia or psychosis have a number of limitations including inability to capture five symptom domains of psychosis and a lack of clearly defined operational anchor points for scoring. We developed a new brief rating scale for five symptom domains of psychosis with clearly defined operational anchor points - the Brief Evaluation of Psychosis Symptom Domains (BE-PSD). To examine the psychometric properties of the BE-PSD, fifty patients with schizophrenia or schizoaffective disorder were included in this preliminary cross-sectional study. To test the convergent and discriminant validity of the BE-PSD, correlational analyses were employed using the consensus Positive and Negative Syndrome Scale (PANSS) five-factor model. To examine the inter-rater reliability of the BE-PSD, single measures intraclass correlation coefficients (ICCs) were calculated for 11 patients. The BE-PSD domain scores demonstrated high convergent validity with the corresponding PANSS factor score (rs = 0.81-0.93) as well as good discriminant validity, as evidenced by lower correlations with the other PANSS factors (rs = 0.23-0.62). The BE-PSD also demonstrated excellent inter-rater reliability for each of the domain scores and the total scores (ICC(2,1) = 0.79-0.96). The present preliminary study found the BE-PSD measure to be valid and reliable; however, further studies are needed to establish the psychometric properties of the BE-PSD because of the limitations such as the small sample size and lacking data on test-retest reliability or sensitivity to change. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Cola soft drinks for evaluating the bioaccessibility of uranium in contaminated mine soils.

    PubMed

    Lottermoser, Bernd G; Schnug, Ewald; Haneklaus, Silvia

    2011-08-15

    There is a rising need for scientifically sound and quantitative as well as simple, rapid, cheap and readily available soil testing procedures. The purpose of this study was to explore selected soft drinks (Coca-Cola Classic®, Diet Coke®, Coke Zero®) as indicators of bioaccessible uranium and other trace elements (As, Ce, Cu, La, Mn, Ni, Pb, Th, Y, Zn) in contaminated soils of the Mary Kathleen uranium mine site, Australia. Data of single extraction tests using Coca-Cola Classic®, Diet Coke® and Coke Zero® demonstrate that extractable arsenic, copper, lanthanum, manganese, nickel, yttrium and zinc concentrations correlate significantly with DTPA- and CaCl₂-extractable metals. Moreover, the correlation between DTPA-extractable uranium and that extracted using Coca-Cola Classic® is close to unity (+0.98), with reduced correlations for Diet Coke® (+0.66) and Coke Zero® (+0.55). Also, Coca-Cola Classic® extracts uranium concentrations near identical to DTPA, whereas distinctly higher uranium fractions were extracted using Diet Coke® and Coke Zero®. Results of this study demonstrate that the use of Coca-Cola Classic® in single extraction tests provided an excellent indication of bioaccessible uranium in the analysed soils and of uranium uptake into leaves and stems of the Sodom apple (Calotropis procera). Moreover, the unconventional reagent is superior in terms of availability, costs, preparation and disposal compared to traditional chemicals. Contaminated site assessments and rehabilitation of uranium mine sites require a solid understanding of the chemical speciation of environmentally significant elements for estimating their translocation in soils and plant uptake. Therefore, Cola soft drinks have potential applications in single extraction tests of uranium contaminated soils and may be used for environmental impact assessments of uranium mine sites, nuclear fuel processing plants and waste storage and disposal facilities. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Psychometric Properties of Translation of the Child Perception Questionnaire (CPQ11-14) in Telugu Speaking Indian Children.

    PubMed

    Kumar, Santhosh; Kroon, Jeroen; Lalloo, Ratilal; Johnson, Newell W

    2016-01-01

    Oral health related quality of life research among children in India is still nascent and no measures have been validated to date. Although CPQ11-14 has been previously used in studies from the Indian sub-continent, the instrument has never been tested for cross-cultural adaptability. This study aimed to assess the validity and reliability of CPQ11-14 in Telugu speaking Indian school children. Primary school children of Medak district, Telangana State, India, were recruited by a multi-stage probability sampling method. The translated questionnaire was initially pilot tested on a small subset of children (n = 40). Children with informed consent from parents (N = 1342) were then provided with questionnaires containing the Telugu translation of CPQ11-14, followed by a clinical examination conducted by a single examiner, using Basic WHO survey methods for dental caries, malocclusion, and Dean's Fluorosis index. Children (n = 161) in randomly chosen schools were re-administered the same questionnaire after a two week interval to test reliability of CPQ11-14 on repeated administrations. Internal consistency and test-retest reliability as determined by Cronbach's alpha and Intra-class correlation coefficient for overall CPQ11-14 scale were 0.925 and 0.923, respectively. CPQ11-14 discriminated between the categories of fluorosis and malocclusion while its discriminant validity with respect to dental caries was limited. CPQ11-14 also demonstrated good construct validity with both overall CPQ11-14 and its subscales having significant positive correlation with global ratings of oral health and overall wellbeing, even after adjusting for confounding variables. CPQ11-14 had a correlation of 0.405 with self-evaluated oral health and 0.407 with self-evaluated impact of oral health on overall wellbeing. In conclusion, Telugu translation of CPQ11-14 demonstrated good internal consistency and excellent reliability on repeated administrations after two weeks. It also exhibited good discriminant and construct validity.

  9. Validation of a health-related quality of life instrument for primary ciliary dyskinesia (QOL-PCD).

    PubMed

    Behan, Laura; Leigh, Margaret W; Dell, Sharon D; Dunn Galvin, Audrey; Quittner, Alexandra L; Lucas, Jane S

    2017-09-01

    Quality of life (QOL)-primary ciliary dyskinesia (PCD) is the first disease-specific, health-related QOL instrument for PCD. Psychometric validation of QOL-PCD assesses the performance of this measure in adults, including its reliability, validity and responsiveness to change. Seventy-two adults (mean (range) age: 33 years (18-79 years); mean (range) FEV 1 % predicted: 68 (26-115)) with PCD completed the 49-item QOL-PCD and generic QOL measures: Short-Form 36 Health Survey, Sino-Nasal Outcome Test 20 (SNOT-20) and St George Respiratory Questionnaire (SGRQ)-C. Thirty-five participants repeated QOL-PCD 10-14 days later to measure stability or reproducibility of the measure. Multitrait analysis was used to evaluate how the items loaded on 10 hypothesised scales: physical, emotional, role and social functioning, treatment burden, vitality, health perceptions, upper respiratory symptoms, lower respiratory symptoms and ears and hearing symptoms. This analysis of item-to-total correlations led to 9 items being dropped; the validated measure now comprises 40 items. Each scale had excellent internal consistency (Cronbach's α: 0.74 to 0.94). Two-week test-retest demonstrated stability for all scales (intraclass coefficients 0.73 to 0.96). Significant correlations were obtained between QOL-PCD scores and age and FEV 1 . Strong relationships were also found between QOL-PCD scales and similar constructs on generic questionnaires, for example, lower respiratory symptoms and SGRQ-C (r=0.72, p<0.001), while weak correlations were found between measures of different constructs. QOL-PCD has demonstrated good internal consistency, test-retest reliability, convergent and divergent validity. QOL-PCD offers a promising tool for evaluating new therapies and for measuring symptoms, functioning and QOL during routine care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Diffusion-weighted magnetic resonance imaging in the characterization of testicular germ cell neoplasms: Effect of ROI methods on apparent diffusion coefficient values and interobserver variability.

    PubMed

    Tsili, Athina C; Ntorkou, Alexandra; Astrakas, Loukas; Xydis, Vasilis; Tsampalas, Stavros; Sofikitis, Nikolaos; Argyropoulou, Maria I

    2017-04-01

    To evaluate the difference in apparent diffusion coefficient (ADC) measurements at diffusion-weighted (DW) magnetic resonance imaging of differently shaped regions-of-interest (ROIs) in testicular germ cell neoplasms (TGCNS), the diagnostic ability of differently shaped ROIs in differentiating seminomas from nonseminomatous germ cell neoplasms (NSGCNs) and the interobserver variability. Thirty-three TGCNs were retrospectively evaluated. Patients underwent MR examinations, including DWI on a 1.5-T MR system. Two observers measured mean tumor ADCs using four distinct ROI methods: round, square, freehand and multiple small, round ROIs. The interclass correlation coefficient was analyzed to assess interobserver variability. Statistical analysis was used to compare mean ADC measurements among observers, methods and histologic types. All ROI methods showed excellent interobserver agreement, with excellent correlation (P<0.001). Multiple, small ROIs provided the lower mean ADC in TGCNs. Seminomas had lower mean ADC compared to NSGCNs for each ROI method (P<0.001). Round ROI proved the most accurate method in characterizing TGCNS. Interobserver variability in ADC measurement is excellent, irrespective of the ROI shape. Multiple, small round ROIs and round ROI proved the more accurate methods for ADC measurement in the characterization of TGCNs and in the differentiation between seminomas and NSGCNs, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Thermodynamics and proton activities of protic ionic liquids with quantum cluster equilibrium theory

    NASA Astrophysics Data System (ADS)

    Ingenmey, Johannes; von Domaros, Michael; Perlt, Eva; Verevkin, Sergey P.; Kirchner, Barbara

    2018-05-01

    We applied the binary Quantum Cluster Equilibrium (bQCE) method to a number of alkylammonium-based protic ionic liquids in order to predict boiling points, vaporization enthalpies, and proton activities. The theory combines statistical thermodynamics of van-der-Waals-type clusters with ab initio quantum chemistry and yields the partition functions (and associated thermodynamic potentials) of binary mixtures over a wide range of thermodynamic phase points. Unlike conventional cluster approaches that are limited to the prediction of thermodynamic properties, dissociation reactions can be effortlessly included into the bQCE formalism, giving access to ionicities, as well. The method is open to quantum chemical methods at any level of theory, but combination with low-cost composite density functional theory methods and the proposed systematic approach to generate cluster sets provides a computationally inexpensive and mostly parameter-free way to predict such properties at good-to-excellent accuracy. Boiling points can be predicted within an accuracy of 50 K, reaching excellent accuracy for ethylammonium nitrate. Vaporization enthalpies are predicted within an accuracy of 20 kJ mol-1 and can be systematically interpreted on a molecular level. We present the first theoretical approach to predict proton activities in protic ionic liquids, with results fitting well into the experimentally observed correlation. Furthermore, enthalpies of vaporization were measured experimentally for some alkylammonium nitrates and an excellent linear correlation with vaporization enthalpies of their respective parent amines is observed.

  12. Use of a Simple, Colorimetric Assay to Demonstrate Conditions for Induction of Nitrate Reductase in Plants.

    ERIC Educational Resources Information Center

    Harley, Suzanne M.

    1993-01-01

    Nitrate assimilation by plants provides an excellent system for demonstrating control of gene expression in a eukaryotic organism. Describes an assay method that allows students to complete experiments designed around the measurement of nitrate reductase within a three-hour laboratory experiment. (PR)

  13. Correlators in simultaneous measurement of non-commuting qubit observables

    NASA Astrophysics Data System (ADS)

    Atalaya, Juan; Hacohen-Gourgy, Shay; Martin, Leigh S.; Siddiqi, Irfan; Korotkov, Alexander N.

    We consider simultaneous continuous measurement of non-commuting qubit observables and analyze multi-time correlators 〈i κ1 (t1) ^i κN (tN) 〉 for output signals i κ (t) from the detectors. Both informational (''spooky'') and phase backactions from cQED-type measurements with phase-sensitive amplifiers are taken into account. We find an excellent agreement between analytical results and experimental data for two-time correlators of the output signals from simultaneous measurement of qubit observables σx and σφ =σx cosφ +σy sinφ . The correlators can be used to extract small deviations of experimental parameters, e.g., phase backaction and residual Rabi frequency. The multi-time correlators are important in analysis of Bacon-Shor error correction/detection codes, operated with continuous measurements.

  14. PedsQL™ Multidimensional Fatigue Scale in sickle cell disease: feasibility, reliability, and validity.

    PubMed

    Panepinto, Julie A; Torres, Sylvia; Bendo, Cristiane B; McCavit, Timothy L; Dinu, Bogdan; Sherman-Bien, Sandra; Bemrich-Stolz, Christy; Varni, James W

    2014-01-01

    Sickle cell disease (SCD) is an inherited blood disorder characterized by a chronic hemolytic anemia that can contribute to fatigue and global cognitive impairment in patients. The study objective was to report on the feasibility, reliability, and validity of the PedsQL™ Multidimensional Fatigue Scale in SCD for pediatric patient self-report ages 5-18 years and parent proxy-report for ages 2-18 years. This was a cross-sectional multi-site study whereby 240 pediatric patients with SCD and 303 parents completed the 18-item PedsQL™ Multidimensional Fatigue Scale. Participants also completed the PedsQL™ 4.0 Generic Core Scales. The PedsQL™ Multidimensional Fatigue Scale evidenced excellent feasibility, excellent reliability for the Total Scale Scores (patient self-report α = 0.90; parent proxy-report α = 0.95), and acceptable reliability for the three individual scales (patient self-report α = 0.77-0.84; parent proxy-report α = 0.90-0.97). Intercorrelations of the PedsQL™ Multidimensional Fatigue Scale with the PedsQL™ Generic Core Scales were predominantly in the large (≥0.50) range, supporting construct validity. PedsQL™ Multidimensional Fatigue Scale Scores were significantly worse with large effects sizes (≥0.80) for patients with SCD than for a comparison sample of healthy children, supporting known-groups discriminant validity. Confirmatory factor analysis demonstrated an acceptable to excellent model fit in SCD. The PedsQL™ Multidimensional Fatigue Scale demonstrated acceptable to excellent measurement properties in SCD. The results demonstrate the relative severity of fatigue symptoms in pediatric patients with SCD, indicating the potential clinical utility of multidimensional assessment of fatigue in patients with SCD in clinical research and practice. © 2013 Wiley Periodicals, Inc.

  15. PedsQL™ Multidimensional Fatigue Scale in Sickle Cell Disease: Feasibility, Reliability and Validity

    PubMed Central

    Panepinto, Julie A.; Torres, Sylvia; Bendo, Cristiane B.; McCavit, Timothy L.; Dinu, Bogdan; Sherman-Bien, Sandra; Bemrich-Stolz, Christy; Varni, James W.

    2013-01-01

    Background Sickle cell disease (SCD) is an inherited blood disorder characterized by a chronic hemolytic anemia that can contribute to fatigue and global cognitive impairment in patients. The study objective was to report on the feasibility, reliability, and validity of the PedsQL™ Multidimensional Fatigue Scale in SCD for pediatric patient self-report ages 5–18 years and parent proxy-report for ages 2–18 years. Procedure This was a cross-sectional multi-site study whereby 240 pediatric patients with SCD and 303 parents completed the 18-item PedsQL™ Multidimensional Fatigue Scale. Participants also completed the PedsQL™ 4.0 Generic Core Scales. Results The PedsQL™ Multidimensional Fatigue Scale evidenced excellent feasibility, excellent reliability for the Total Scale Scores (patient self-report α = 0.90; parent proxy-report α = 0.95), and acceptable reliability for the three individual scales (patient self-report α = 0.77–0.84; parent proxy-report α = 0.90–0.97). Intercorrelations of the PedsQL™ Multidimensional Fatigue Scale with the PedsQL™ Generic Core Scales were predominantly in the large (≥ 0.50) range, supporting construct validity. PedsQL™ Multidimensional Fatigue Scale Scores were significantly worse with large effects sizes (≥0.80) for patients with SCD than for a comparison sample of healthy children, supporting known-groups discriminant validity. Confirmatory factor analysis demonstrated an acceptable to excellent model fit in SCD. Conclusions The PedsQL™ Multidimensional Fatigue Scale demonstrated acceptable to excellent measurement properties in SCD. The results demonstrate the relative severity of fatigue symptoms in pediatric patients with SCD, indicating the potential clinical utility of multidimensional assessment of fatigue in patients with SCD in clinical research and practice. PMID:24038960

  16. Using Academy Standards of Excellence in Nutrition and Dietetics for organization self-assessment and quality improvement.

    PubMed

    Price, Joyce A; Kent, Sue; Cox, Sharon A; McCauley, Sharon M; Parekh, Janki; Klein, Catherine J

    2014-08-01

    Standards of Excellence in Nutrition and Dietetics for an Organization is a self-assessment tool to measure and evaluate an organization's program, services, and initiatives that identify and distinguish the Registered Dietitian Nutritionist (RDN) brand as the professional expert in food and nutrition. The Standards of Excellence will serve as a road map to recognize RDNs as leaders and collaborators. Standards of Excellence criteria apply to all practice segments of nutrition and dietetics: health care, education and research, business and industry, and community nutrition and public health. Given the membership's call to action to be recognized for their professional expertise, the Academy of Nutrition and Dietetics Quality Management Committee developed four Standards of Excellence in Nutrition and Dietetics for Organizations: Quality of Leadership, Quality of Organization, Quality of Practice, and Quality of Outcomes. Within each standard, specific indicators provide strategies for an organization to demonstrate excellence. The Academy will develop a self-evaluation scoring tool to assist the organization in applying and implementing one or more of the strategies in the Standards of Excellence indicators. The organization can use the self-assessment tool to establish itself as a Center of Excellence in Nutrition and Dietetics. The role examples illustrate initiatives RDNs and organizations can take to identify themselves as a Center of Excellence in Nutrition and Dietetics. Achieving the Excellence level is an important collaborative initiative between nutrition and dietetics organizations and the Academy to provide increased autonomy, supportive management, respect within peers and community, opportunities for professional development, support for further education, and compensation for the RDN. For purposes of the Standards, "organization" means workplace or practice setting. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  17. Assessment of the accuracy of a new tool for the screening of smartphone addiction

    PubMed Central

    2017-01-01

    Objective To translate, adapt and validate the Smartphone Addiction Inventory (SPAI) in a Brazilian population of young adults. Method We employed the translation and back-translation method for the adaptation of the Brazilian version SPAI (SPAI-BR). The sample consisted of 415 university students. Data was collected through an electronic questionnaire, which consisted of the SPAI-BR and the Goodman Criteria (gold standard). The retests were carried out 10–15 days after the initial tests with 130 individuals. Results The SPAI-BR maintained semantic, idiomatic and conceptual equivalences from the original scale. The Confirmatory Factor Analysis confirmed the One-factor model of the SPAI with good fit indexes (x2 = 767.861, CFI = 0.913, TLI = 0.905, RMSE = 0.061, WRMR = 1.465). The Kuder-Richardson Coefficient showed good internal consistency. The analysis of the ROC curve established an area under the curve of 86.38%. The Intraclass-Correlation Coefficient of 0.926 between the test and the retest demonstrated an excellent temporal stability. The high correlation between SPAI-BR and the Goodman Criteria (rs = 0.750) established the convergent validity. Conclusion The SPAI-BR is a valid and reliable tool for the detection of Smartphone Addiction in Brazilian university students. PMID:28520798

  18. Advances in Measuring Culturally Competent Care: A Confirmatory Factor Analysis of CAHPS-CC in a Safety-net Population

    PubMed Central

    Stern, RJ; Fernandez, A; Jacobs, EA; Neilands, TB; Weech-Maldonado, R; Quan, J; Carle, A; Seligman, HK

    2012-01-01

    Background Providing culturally competent care shows promise as a mechanism to reduce healthcare inequalities. Until the recent development of the CAHPS Cultural Competency Item Set (CAHPS-CC), no measures capturing patient-level experiences with culturally competent care have been suitable for broad-scale administration. Methods We performed confirmatory factor analysis and internal consistency reliability analysis of CAHPS-CC among patients with type 2 diabetes (n=600) receiving primary care in safety-net clinics. CAHPS-CC domains were also correlated with global physician ratings. Results A 7-factor model demonstrated satisfactory fit (χ2(231)=484.34, p<.0001) with significant factor loadings at p<.05. Three domains showed excellent reliability – Doctor Communication- Positive Behaviors (α=.82), Trust (α=.77), and Doctor Communication- Health Promotion (α=.72). Four domains showed inadequate reliability either among Spanish speakers or overall (overall reliabilities listed): Doctor Communication- Negative Behaviors (α=.54), Equitable Treatment (α=.69), Doctor Communication- Alternative Medicine (α=.52), and Shared Decision-Making (α=.51). CAHPS-CC domains were positively and significantly correlated with global physician rating. Conclusions Select CAHPS-CC domains are suitable for broad-scale administration among safety-net patients. Those domains may be used to target quality-improvement efforts focused on providing culturally competent care in safety-net settings. PMID:22895231

  19. Reynolds Number Effects at High Angles of Attack

    NASA Technical Reports Server (NTRS)

    Fisher, David F.; Cobleigh, Brent R.; Banks, Daniel W.; Hall, Robert M.; Wahls, Richard A.

    1998-01-01

    Lessons learned from comparisons between ground-based tests and flight measurements for the high-angle-of-attack programs on the F-18 High Alpha Research Vehicle (HARV), the X-29 forward-swept wing aircraft, and the X-31 enhanced fighter maneuverability aircraft are presented. On all three vehicles, Reynolds number effects were evident on the forebodies at high angles of attack. The correlation between flight and wind tunnel forebody pressure distributions for the F-18 HARV were improved by using twin longitudinal grit strips on the forebody of the wind-tunnel model. Pressure distributions obtained on the X-29 wind-tunnel model at flight Reynolds numbers showed excellent correlation with the flight data up to alpha = 50 deg. Above (alpha = 50 deg. the pressure distributions for both flight and wind tunnel became asymmetric and showed poorer agreement, possibly because of the different surface finish of the model and aircraft. The detrimental effect of a very sharp nose apex was demonstrated on the X-31 aircraft. Grit strips on the forebody of the X-31 reduced the randomness but increased the magnitude of the asymmetry. Nose strakes were required to reduce the forebody yawing moment asymmetries and the grit strips on the flight test noseboom improved the aircraft handling qualities.

  20. Power balance and loss mechanism analysis in RF transmit coil arrays.

    PubMed

    Kuehne, Andre; Goluch, Sigrun; Waxmann, Patrick; Seifert, Frank; Ittermann, Bernd; Moser, Ewald; Laistler, Elmar

    2015-10-01

    To establish a framework for transmit array power balance calculations based on power correlation matrices to accurately quantify the loss contributions from different mechanisms such as coupling, lumped components, and radiation. Starting from Poynting's theorem, power correlation matrices are derived for all terms in the power balance, which is formulated as a matrix equation. Finite-difference time-domain simulations of two 7 T eight-channel head array coils at 297.2 MHz are used to verify the theoretical considerations and demonstrate their application. Care is taken to accurately incorporate all loss mechanisms. The power balance for static B1 phase shims as well as two-dimensional spatially selective transmit SENSE pulses is shown. The simulated power balance shows an excellent agreement with theory, with a maximum power imbalance of less than 0.11%. Power loss contributions from the different loss mechanisms vary significantly between the investigated setups, and depending on the excitation mode imposed on the coil. The presented approach enables a straightforward loss evaluation for an arbitrary excitation of transmit coil arrays. Worst-case power imbalance and losses are calculated in a straightforward manner. This allows for deeper insight into transmit array loss mechanisms, incorporation of radiated power components in specific absorption rate calculations and verification of electromagnetic simulations. © 2014 Wiley Periodicals, Inc.

  1. Test-retest reliability of the safe driving behavior measure for community-dwelling elderly drivers.

    PubMed

    Song, Chiang-Soon; Lee, Joo-Hyun; Han, Sang-Woo

    2016-06-01

    [Purpose] The Safe Driving Behavior Measure (SDBM) is a self-report measurement tools that assesses the safe-driving behaviors of the elderly. The purpose of this study was to evaluate the test-retest reliability of the SDBM among community-dwelling elderly drivers. [Subjects and Methods] A total of sixty-one community-dwelling elderly were enrolled to investigate the reliability of the SDBM. The SDBM was assessed in two sessions that were conducted three days apart in a quiet and well-organized assessment room. That test-retest reliability of overall scores and three domain scores of the SDBM were statistically evaluated using intraclass correlation coefficients [ICC (2.1)]. Pearson correlation coefficients were used to quantify bivariate associations among the three domains of the SDBM. [Results] The SDBM demonstrated excellent rest-retest reliability for community-dwelling elderly drivers. The Cronbach alpha coefficients of the three domains of person-vehicle (0.979), person-environment (0.944), and person-vehicle-environment (0.971) of the SDBM indicate high internal consistency. [Conclusion] The results of this study suggest that the SDBM is a reliable measure for evaluating the safe- driving of automobiles by community-dwelling elderly, and is adequate for detecting changes in scores in clinical settings.

  2. Enhanced O-2 Selectivity versus N-2 by Partial Metal Substitution in Cu-BTC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sava Gallis, Dorina F.; Parkes, Marie V.; Greathouse, Jeffery A.

    2015-03-24

    Here, we describe the homogeneous substitution of Mn, Fe, and Co at various levels into a prototypical metal organic framework (MOP), namely Cu-BTC (HKUST-1), and the effect of that substitution on preferential gas sorption. Using a combination of density functional theory (DFT) calculations, postsynthetic metal substitutions, materials characterization, and gas sorption testing, we demonstrate that the identity of the metal ion has a quantifiable effect on their oxygen and nitrogen sorption properties at cryogenic temperatures. An excellent correlation is found between O-2/N-2 selectivities determined experimentally at 77 K and the difference in O-2 and N-2 binding energies calculated from DFTmore » modeling data: Mn > Fe Co >> Cu. Room temperature gas sorption studies were also performed and correlated with metal substitution. The Fe-exchanged sample shows a significantly higher nitrogen isosteric heat of adsorption at temperatures close to ambient conditions (273-298 K) as compared to all other metals studied, indicative of favorable interactions between N-2 and coordinatively unsaturated Fe metal centers. Interestingly, differences in gas adsorption results at cryogenic and room temperatures are evident; they are explained by comparing experimental results with DFT binding energies (0 K) and room temperature Grand Canonical Monte Carlo simulations.« less

  3. High-throughput electrical characterization for robust overlay lithography control

    NASA Astrophysics Data System (ADS)

    Devender, Devender; Shen, Xumin; Duggan, Mark; Singh, Sunil; Rullan, Jonathan; Choo, Jae; Mehta, Sohan; Tang, Teck Jung; Reidy, Sean; Holt, Jonathan; Kim, Hyung Woo; Fox, Robert; Sohn, D. K.

    2017-03-01

    Realizing sensitive, high throughput and robust overlay measurement is a challenge in current 14nm and advanced upcoming nodes with transition to 300mm and upcoming 450mm semiconductor manufacturing, where slight deviation in overlay has significant impact on reliability and yield1). Exponentially increasing number of critical masks in multi-patterning lithoetch, litho-etch (LELE) and subsequent LELELE semiconductor processes require even tighter overlay specification2). Here, we discuss limitations of current image- and diffraction- based overlay measurement techniques to meet these stringent processing requirements due to sensitivity, throughput and low contrast3). We demonstrate a new electrical measurement based technique where resistance is measured for a macro with intentional misalignment between two layers. Overlay is quantified by a parabolic fitting model to resistance where minima and inflection points are extracted to characterize overlay control and process window, respectively. Analyses using transmission electron microscopy show good correlation between actual overlay performance and overlay obtained from fitting. Additionally, excellent correlation of overlay from electrical measurements to existing image- and diffraction- based techniques is found. We also discuss challenges of integrating electrical measurement based approach in semiconductor manufacturing from Back End of Line (BEOL) perspective. Our findings open up a new pathway for accessing simultaneous overlay as well as process window and margins from a robust, high throughput and electrical measurement approach.

  4. Statistical analysis on the concordance of the radiological evaluation of fractures of the distal radius subjected to traction☆

    PubMed Central

    Machado, Daniel Gonçalves; da Cruz Cerqueira, Sergio Auto; de Lima, Alexandre Fernandes; de Mathias, Marcelo Bezerra; Aramburu, José Paulo Gabbi; Rodarte, Rodrigo Ribeiro Pinho

    2016-01-01

    Objective The objective of this study was to evaluate the current classifications for fractures of the distal extremity of the radius, since the classifications made using traditional radiographs in anteroposterior and lateral views have been questioned regarding their reproducibility. In the literature, it has been suggested that other options are needed, such as use of preoperative radiographs on fractures of the distal radius subjected to traction, with stratification by the evaluators. The aim was to demonstrate which classification systems present better statistical reliability. Results In the Universal classification, the results from the third-year resident group (R3) and from the group of more experienced evaluators (Staff) presented excellent correlation, with a statistically significant p-value (p < 0.05). Neither of the groups presented a statistically significant result through the Frykman classification. In the AO classification, there were high correlations in the R3 and Staff groups (respectively 0.950 and 0.800), with p-values lower than 0.05 (respectively <0.001 and 0.003). Conclusion It can be concluded that radiographs performed under traction showed good concordance in the Staff group and in the R3 group, and that this is a good tactic for radiographic evaluations of fractures of the distal extremity of the radius. PMID:26962498

  5. Development of the Therapist Empathy Scale.

    PubMed

    Decker, Suzanne E; Nich, Charla; Carroll, Kathleen M; Martino, Steve

    2014-05-01

    Few measures exist to examine therapist empathy as it occurs in session. A 9-item observer rating scale, called the Therapist Empathy Scale (TES), was developed based on Watson's (1999) work to assess affective, cognitive, attitudinal, and attunement aspects of therapist empathy. The aim of this study was to evaluate the inter-rater reliability, internal consistency, and construct and criterion validity of the TES. Raters evaluated therapist empathy in 315 client sessions conducted by 91 therapists, using data from a multi-site therapist training trial (Martino et al., 2010) in Motivational Interviewing (MI). Inter-rater reliability (ICC = .87 to .91) and internal consistency (Cronbach's alpha = .94) were high. Confirmatory factor analyses indicated some support for single-factor fit. Convergent validity was supported by correlations between TES scores and MI fundamental adherence (r range .50 to .67) and competence scores (r range .56 to .69). Discriminant validity was indicated by negative or nonsignificant correlations between TES and MI-inconsistent behavior (r range .05 to -.33). The TES demonstrates excellent inter-rater reliability and internal consistency. RESULTS indicate some support for a single-factor solution and convergent and discriminant validity. Future studies should examine the use of the TES to evaluate therapist empathy in different psychotherapy approaches and to determine the impact of therapist empathy on client outcome.

  6. Enhanced O 2 selectivity versus N 2 by partial metal substitution in Cu-BTC

    DOE PAGES

    Sava Gallis, Dorina F.; Parkes, Marie V.; Greathouse, Jeffery A.; ...

    2015-03-05

    Here we describe the homogeneous substitution of Mn, Fe and Co at various levels into a prototypical metal-organic framework (MOF), namely Cu-BTC (HKUST-1), and the effect of that substitution on preferential gas sorption. Using a combination of density functional theory (DFT) calculations, postsynthetic metal substitutions, materials characterization, and gas sorption testing, we demonstrate that the identity of the metal ion has a quantifiable effect on their oxygen and nitrogen sorption properties at cryogenic temperatures. An excellent correlation is found between O 2/N 2 selectivities determined experimentally at 77 K and the difference in O 2 and N 2 binding energiesmore » calculated from DFT modeling data: Mn > Fe > Co > Cu. Room temperature gas sorption studies were also performed and correlated with metal substitution. The Fe-exchanged sample shows a significantly higher nitrogen isosteric heat of adsorption at temperatures close to ambient conditions (273 K - 298 K) as compared to all other metals studied, indicative of favorable interactions between N 2 and coordinatively unsaturated Fe metal centers. Furthermore, differences in gas adsorption results at cryogenic and room temperatures are evident; they are explained by comparing experimental results with DFT binding energies (0 K) and room temperature Grand Canonical Monte Carlo simulations.« less

  7. Synthesis of sub-10 nm solid lipid nanoparticles for topical and biomarker detection applications

    NASA Astrophysics Data System (ADS)

    Calderón-Colón, Xiomara; Patchan, Marcia W.; Theodore, Mellisa L.; Le, Huong T.; Sample, Jennifer L.; Benkoski, Jason J.; Patrone, Julia B.

    2014-02-01

    Solid lipid nanoparticles (SLNs) are a promising platform for sensing in vivo biomarkers due to their biocompatibility, stability, and their ability to carry a wide range of active ingredients. The skin is a prominent target organ for numerous inflammatory and stress-related biomarkers, making it an excellent site for early detection of physiological imbalance and application of sensory nanoparticles. Though smaller particle size has generally been correlated with increased penetration of skin models, there has been little attention paid to the significance of other nanoparticle synthesis parameters with respect to their physical properties. In this study, we demonstrate the synthesis of sub-10 nm SLNs by the phase inversion temperature (PIT) method. These particles were specifically designed for topical delivery of hydrogen peroxide-detecting chemiluminescent dyes. A systematic design of experiments approach was used to investigate the role of the processing variables on SLN form and properties. The processing variables were correlated with the SLN properties (e.g., dye solubility, phase inversion temperature, particle size, polydispersity, melting point, and latent heat of melting). Statistical analysis revealed that the PIT method, while allowing total control over the thermal properties, resulted in well-controlled synthesis of ultra-small particles, while allowing great flexibility in the processing conditions and incorporated compounds.

  8. Correlation between discrete probability and reaction front propagation rate in heterogeneous mixtures

    NASA Astrophysics Data System (ADS)

    Naine, Tarun Bharath; Gundawar, Manoj Kumar

    2017-09-01

    We demonstrate a very powerful correlation between the discrete probability of distances of neighboring cells and thermal wave propagation rate, for a system of cells spread on a one-dimensional chain. A gamma distribution is employed to model the distances of neighboring cells. In the absence of an analytical solution and the differences in ignition times of adjacent reaction cells following non-Markovian statistics, invariably the solution for thermal wave propagation rate for a one-dimensional system with randomly distributed cells is obtained by numerical simulations. However, such simulations which are based on Monte-Carlo methods require several iterations of calculations for different realizations of distribution of adjacent cells. For several one-dimensional systems, differing in the value of shaping parameter of the gamma distribution, we show that the average reaction front propagation rates obtained by a discrete probability between two limits, shows excellent agreement with those obtained numerically. With the upper limit at 1.3, the lower limit depends on the non-dimensional ignition temperature. Additionally, this approach also facilitates the prediction of burning limits of heterogeneous thermal mixtures. The proposed method completely eliminates the need for laborious, time intensive numerical calculations where the thermal wave propagation rates can now be calculated based only on macroscopic entity of discrete probability.

  9. Two-Electron Correlations in e+H-->e+e+p Near Threshold

    NASA Astrophysics Data System (ADS)

    Kato, Daiji; Watanabe, Shinichi

    1995-03-01

    We present an ab initio calculation of the ionization cross section of atomic hydrogen near threshold with precision that compares excellently with the Shah-Elliot-Gilbody experiment [J. Phys. B 20, 3501 (1987)]. This fills the gap between theory and experiment down to 0.1 a.u. above threshold, complementing the recent spectacular work of Bray and Stelbovics [Phys. Rev. Lett. 70, 746 (1993)]. The angular momentum distributions of the secondary electron display an evolution in correlation patterns toward the threshold.

  10. Reliability of conditioned pain modulation: a systematic review

    PubMed Central

    Kennedy, Donna L.; Kemp, Harriet I.; Ridout, Deborah; Yarnitsky, David; Rice, Andrew S.C.

    2016-01-01

    Abstract A systematic literature review was undertaken to determine if conditioned pain modulation (CPM) is reliable. Longitudinal, English language observational studies of the repeatability of a CPM test paradigm in adult humans were included. Two independent reviewers assessed the risk of bias in 6 domains; study participation; study attrition; prognostic factor measurement; outcome measurement; confounding and analysis using the Quality in Prognosis Studies (QUIPS) critical assessment tool. Intraclass correlation coefficients (ICCs) less than 0.4 were considered to be poor; 0.4 and 0.59 to be fair; 0.6 and 0.75 good and greater than 0.75 excellent. Ten studies were included in the final review. Meta-analysis was not appropriate because of differences between studies. The intersession reliability of the CPM effect was investigated in 8 studies and reported as good (ICC = 0.6-0.75) in 3 studies and excellent (ICC > 0.75) in subgroups in 2 of those 3. The assessment of risk of bias demonstrated that reporting is not comprehensive for the description of sample demographics, recruitment strategy, and study attrition. The absence of blinding, a lack of control for confounding factors, and lack of standardisation in statistical analysis are common. Conditioned pain modulation is a reliable measure; however, the degree of reliability is heavily dependent on stimulation parameters and study methodology and this warrants consideration for investigators. The validation of CPM as a robust prognostic factor in experimental and clinical pain studies may be facilitated by improvements in the reporting of CPM reliability studies. PMID:27559835

  11. Chemiresistive Graphene Sensors for Ammonia Detection.

    PubMed

    Mackin, Charles; Schroeder, Vera; Zurutuza, Amaia; Su, Cong; Kong, Jing; Swager, Timothy M; Palacios, Tomás

    2018-05-09

    The primary objective of this work is to demonstrate a novel sensor system as a convenient vehicle for scaled-up repeatability and the kinetic analysis of a pixelated testbed. This work presents a sensor system capable of measuring hundreds of functionalized graphene sensors in a rapid and convenient fashion. The sensor system makes use of a novel array architecture requiring only one sensor per pixel and no selector transistor. The sensor system is employed specifically for the evaluation of Co(tpfpp)ClO 4 functionalization of graphene sensors for the detection of ammonia as an extension of previous work. Co(tpfpp)ClO 4 treated graphene sensors were found to provide 4-fold increased ammonia sensitivity over pristine graphene sensors. Sensors were also found to exhibit excellent selectivity over interfering compounds such as water and common organic solvents. The ability to monitor a large sensor array with 160 pixels provides insights into performance variations and reproducibility-critical factors in the development of practical sensor systems. All sensors exhibit the same linearly related responses with variations in response exhibiting Gaussian distributions, a key finding for variation modeling and quality engineering purposes. The mean correlation coefficient between sensor responses was found to be 0.999 indicating highly consistent sensor responses and excellent reproducibility of Co(tpfpp)ClO 4 functionalization. A detailed kinetic model is developed to describe sensor response profiles. The model consists of two adsorption mechanisms-one reversible and one irreversible-and is shown capable of fitting experimental data with a mean percent error of 0.01%.

  12. Determination of six sulfonylurea herbicides in environmental water samples by magnetic solid-phase extraction using multi-walled carbon nanotubes as adsorbents coupled with high-performance liquid chromatography.

    PubMed

    Ma, Jiping; Jiang, Lianhua; Wu, Gege; Xia, Yan; Lu, Wenhui; Li, Jinhua; Chen, Lingxin

    2016-09-30

    Magnetic solid-phase extraction (MSPE) using magnetic multi-walled carbon nanotubes (mag-MWCNTs) as adsorbents, coupled with high-performance liquid chromatography-diode-array detector (HPLC-DAD), was developed for the simultaneous separation and determination of six types of sulfonylurea herbicides (SUs) in environmental water samples. Several variables affecting MSPE efficiency were systematically investigated, including the type and volume of desorption solvent, sample solution pH, salt concentration, amount of mag-MWCNTs, and extraction and desorption time. Response surface was employed to assist in the MSPE optimization. Under optimized conditions, excellent linearity was achieved in the range of 0.05-5.0μg/L for all six SUs, with coefficients of correlation r>0.9994, and preconcentration factors ranging from 178 to 210. Limits of detection and quantification were 0.01-0.04μg/L and 0.03-0.13μg/L, respectively. The intra-day and inter-day precision (relative standard deviations, n=6, %) at three spiked levels were 2.0-11.0% and 2.1-12.9% in terms of peak area, respectively. The method recoveries at three fortified concentrations were obtained within 76.7-106.9% for reservoir water samples and 78.2-105.4% for tap water samples. The developed MSPE-HPLC method demonstrated high sensitivity, repeatability, simplicity, rapidity, and excellent practical applicability. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A Correction Equation for Jump Height Measured Using the Just Jump System.

    PubMed

    McMahon, John J; Jones, Paul A; Comfort, Paul

    2016-05-01

    To determine the concurrent validity and reliability of the popular Just Jump system (JJS) for determining jump height and, if necessary, provide a correction equation for future reference. Eighteen male college athletes performed 3 bilateral countermovement jumps (CMJs) on 2 JJSs (alternative method) that were placed on top of a force platform (criterion method). Two JJSs were used to establish consistency between systems. Jump height was calculated from flight time obtained from the JJS and force platform. Intraclass correlation coefficients (ICCs) demonstrated excellent within-session reliability of the CMJ height measurement derived from both the JJS (ICC = .96, P < .001) and the force platform (ICC = .96, P < .001). Dependent t tests revealed that the JJS yielded a significantly greater CMJ jump height (0.46 ± 0.09 m vs 0.33 ± 0.08 m) than the force platform (P < .001, Cohen d = 1.39, power = 1.00). There was, however, an excellent relationship between CMJ heights derived from the JJS and force platform (r = .998, P < .001, power = 1.00), with a coefficient of determination (R2) of .995. Therefore, the following correction equation was produced: Criterion jump height = (0.8747 × alternative jump height) - 0.0666. The JJS provides a reliable but overestimated measure of jump height. It is suggested, therefore, that practitioners who use the JJS as part of future work apply the correction equation presented in this study to resultant jump-height values.

  14. Cross-cultural adaptation and validation of the Injury-Psychological Readiness to Return to Sport scale to Persian language.

    PubMed

    Naghdi, Soofia; Nakhostin Ansari, Noureddin; Farhadi, Yasaman; Ebadi, Safoora; Entezary, Ebrahim; Glazer, Douglas

    2016-10-01

    The aim of the present study was to develop and provide validation statistics for the Persian Injury-Psychological Readiness to Return to Sport scale (I-PRRS) following a cross-sectional and prospective cohort study design. The I-PRRS was forward/back-translated and culturally adapted into Persian language. The Persian I-PRRS was administered to 100 injured athletes (93 male; age 26.0 ± 5.6 years; time since injury 4.84 ± 6.4 months) and 50 healthy athletes (36 male; mean age 25.7 ± 6.0 years). The Persian I-PRRS was re-administered to 50 injured athletes at 1 week to examine test-retest reliability. There were no floor or ceiling effects confirming the content validity of Persian I-PRRS. The internal consistency reliability was good. Excellent test-retest reliability and agreement were demonstrated. The statistically significant difference in Persian I-PRRS total scores between the injured athletes and healthy athletes provides an evidence of discriminative validity. The Persian I-PRRS total scores were positively correlated with the Farsi Mood Scale (FARMS) total scores, showing construct validity. The principal component analysis indicated a two-factor solution consisting of "Confidence to play" and "Confidence in the injured body part and skill level". The Persian I-PRRS showed excellent reliability and validity and can be used to assess injured athletes' psychological readiness to return to sport among Persian-speaking populations.

  15. Immunohistochemical application of a highly sensitive and specific murine monoclonal antibody recognising the extracellular domain of the human hepatocyte growth factor receptor (MET).

    PubMed

    Gruver, Aaron M; Liu, Ling; Vaillancourt, Peter; Yan, Sau-Chi B; Cook, Joel D; Roseberry Baker, Jessica A; Felke, Erin M; Lacy, Megan E; Marchal, Christophe C; Szpurka, Hadrian; Holzer, Timothy R; Rhoads, Emily K; Zeng, Wei; Wortinger, Mark A; Lu, Jirong; Chow, Chi-kin; Denning, Irene J; Beuerlein, Gregory; Davies, Julian; Hanson, Jeff C; Credille, Kelly M; Wijayawardana, Sameera R; Schade, Andrew E

    2014-12-01

    Development of novel targeted therapies directed against hepatocyte growth factor (HGF) or its receptor (MET) necessitates the availability of quality diagnostics to facilitate their safe and effective use. Limitations of some commercially available anti-MET antibodies have prompted development of the highly sensitive and specific clone A2H2-3. Here we report its analytical properties when applied by an automated immunohistochemistry method. Excellent antibody specificity was demonstrated by immunoblot, ELISA, and IHC evaluation of characterised cell lines including NIH3T3 overexpressing the related kinase MST1R (RON). Sensitivity was confirmed by measurements of MET in cell lines or characterised tissues. IHC correlated well with FISH and quantitative RT-PCR assessments of MET (P < 0.001). Good total agreement (89%) was observed with the anti-MET antibody clone SP44 using whole-tissue sections, but poor positive agreement (21-47%) was seen in tissue microarray cores. Multiple lots displayed appropriate reproducibility (R(2)  > 0.9). Prevalence of MET positivity by IHC was higher in non-squamous cell NSCLC, MET or EGFR amplified cases, and in tumours harbouring abnormalities in EGFR exon 19 or 21. The anti-MET antibody clone A2H2-3 displays excellent specificity and sensitivity. These properties make it suitable for clinical trial investigations and development as a potential companion diagnostic. © 2014 The Authors. Histopathology Published by John Wiley & Sons Ltd.

  16. Using a dry electrode EEG device during balance tasks in healthy young-adult males: Test-retest reliability analysis.

    PubMed

    Collado-Mateo, Daniel; Adsuar, Jose C; Olivares, Pedro R; Cano-Plasencia, Ricardo; Gusi, Narcis

    2015-01-01

    The analysis of brain activity during balance is an important topic in different fields of science. Given that all measurements involve an error that is caused by different agents, like the instrument, the researcher, or the natural human variability, a test-retest reliability evaluation of the electroencephalographic assessment is a needed starting point. However, there is a lack of information about the reliability of electroencephalographic measurements, especially in a new wireless device with dry electrodes. The current study aims to analyze the reliability of electroencephalographic measurements from a wireless device using dry electrodes during two different balance tests. Seventeen healthy male volunteers performed two different static balance tasks on a Biodex Balance Platform: (a) with two feet on the platform and (b) with one foot on the platform. Electroencephalographic data was recorded using Enobio (Neuroelectrics). The mean power spectrum of the alpha band of the central and frontal channels was calculated. Relative and absolute indices of reliability were also calculated. In general terms, the intraclass correlation coefficient (ICC) values of all the assessed channels can be classified as excellent (>0.90). The percentage standard error of measurement oscillated from 0.54% to 1.02% and the percentage smallest real difference ranged from 1.50% to 2.82%. Electroencephalographic assessment through an Enobio device during balance tasks has an excellent reliability. However, its utility was not demonstrated because responsiveness was not assessed.

  17. Improving Conceptual Understanding and Representation Skills Through Excel-Based Modeling

    NASA Astrophysics Data System (ADS)

    Malone, Kathy L.; Schunn, Christian D.; Schuchardt, Anita M.

    2018-02-01

    The National Research Council framework for science education and the Next Generation Science Standards have developed a need for additional research and development of curricula that is both technologically model-based and includes engineering practices. This is especially the case for biology education. This paper describes a quasi-experimental design study to test the effectiveness of a model-based curriculum focused on the concepts of natural selection and population ecology that makes use of Excel modeling tools (Modeling Instruction in Biology with Excel, MBI-E). The curriculum revolves around the bio-engineering practice of controlling an invasive species. The study takes place in the Midwest within ten high schools teaching a regular-level introductory biology class. A post-test was designed that targeted a number of common misconceptions in both concept areas as well as representational usage. The results of a post-test demonstrate that the MBI-E students significantly outperformed the traditional classes in both natural selection and population ecology concepts, thus overcoming a number of misconceptions. In addition, implementing students made use of more multiple representations as well as demonstrating greater fascination for science.

  18. Coronary artery disease reporting and data system (CAD-RADSTM): Inter-observer agreement for assessment categories and modifiers.

    PubMed

    Maroules, Christopher D; Hamilton-Craig, Christian; Branch, Kelley; Lee, James; Cury, Roberto C; Maurovich-Horvat, Pál; Rubinshtein, Ronen; Thomas, Dustin; Williams, Michelle; Guo, Yanshu; Cury, Ricardo C

    The Coronary Artery Disease Reporting and Data System (CAD-RADS) provides a lexicon and standardized reporting system for coronary CT angiography. To evaluate inter-observer agreement of the CAD-RADS among an panel of early career and expert readers. Four early career and four expert cardiac imaging readers prospectively and independently evaluated 50 coronary CT angiography cases using the CAD-RADS lexicon. All readers assessed image quality using a five-point Likert scale, with mean Likert score ≥4 designating high image quality, and <4 designating moderate/low image quality. All readers were blinded to medical history and invasive coronary angiography findings. Inter-observer agreement for CAD-RADS assessment categories and modifiers were assessed using intra-class correlation (ICC) and Fleiss' Kappa (κ).The impact of reader experience and image quality on inter-observer agreement was also examined. Inter-observer agreement for CAD-RADS assessment categories was excellent (ICC 0.958, 95% CI 0.938-0.974, p < 0.0001). Agreement among expert readers (ICC 0.925, 95% CI 0.884-0.954) was marginally stronger than for early career readers (ICC 0.904, 95% CI 0.852-0.941), both p < 0.0001. High image quality was associated with stronger agreement than moderate image quality (ICC 0.944, 95% CI 0.886-0.974 vs. ICC 0.887, 95% CI 0.775-0.95, both p < 0.0001). While excellent inter-observer agreement was observed for modifiers S (stent) and G (bypass graft) (both κ = 1.0), only fair agreement (κ = 0.40) was observed for modifier V (high risk plaque). Inter-observer reproducibility of CAD-RADS assessment categories and modifiers is excellent, except for high-risk plaque (modifier V) which demonstrates fair agreement. These results suggest CAD-RADS is feasible for clinical implementation. Copyright © 2017. Published by Elsevier Inc.

  19. Strategies to Enhance Interpersonal Relations in Academic Advising

    ERIC Educational Resources Information Center

    Hughey, Judy K.

    2011-01-01

    The relationship between interpersonal skills is positively correlated with effective academic advising. Professional academic advisors feel significant pressure to meet a wide array of student needs, increase retention rates, help students in their efforts of academic achievement and career exploration, and support institutions to excel in…

  20. Central Corneal Thickness Reproducibility among Ten Different Instruments.

    PubMed

    Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco

    2016-11-01

    To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.

  1. The usability of a WeChat-based electronic questionnaire for collecting participant-reported data in female pelvic floor disorders: a comparison with the traditional paper-administered format.

    PubMed

    Sun, Zhi-Jing; Zhu, Lan; Liang, Maolian; Xu, Tao; Lang, Jing-He

    2016-08-01

    WeChat is a promising tool for capturing electronic data; however, no research has examined its use. This study evaluates the reliability and feasibility of WeChat for administering the Pelvic Floor Impact Questionnaire Short Form 7 questionnaire to women with pelvic floor disorders. Sixty-eight pelvic floor rehabilitation women were recruited between June and December 2015 and crossover randomized to two groups. All participants completed two questionnaire formats. One group completed the paper version followed by the WeChat version; the other group completed the questionnaires in reverse order. Two weeks later, each group completed the two versions in reverse order. The WeChat version's reliability was assessed using intraclass correlation coefficients and test-retest reliability. Forty-two women (61.8%) preferred the WeChat to the paper format, eight (11.8%) preferred the paper format, and 18 (26.5%) had no preference. The younger women preferred WeChat. Completion time was 116.5 (61.3) seconds for the WeChat version and 133.4 (107.0) seconds for the paper version, with no significant difference (P = 0.145). Age and education did not impact completion time (P > 0.05). Consistency between the WeChat and paper versions was excellent. The intraclass correlation coefficients of the Pelvic Floor Impact Questionnaire Short Form 7 and the three subscales ranged from 0.915 to 0.980. The Bland-Altman analysis and linear regression results also showed high consistency. The test-retest study had a Pearson's correlation coefficient of 0.908, demonstrating a strong correlation. WeChat-based questionnaires were well accepted by women with pelvic floor disorders and had good data quality and reliability.

  2. Can we have an overall osteoarthritis severity score for the patellofemoral joint using magnetic resonance imaging? Reliability and validity.

    PubMed

    Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos

    2018-04-01

    This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.

  3. Accurate ab initio calculations which demonstrate a 3 Pi u ground state for Al2

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Partridge, Harry; Langhoff, Stephen R.; Taylor, Peter R.; Walch, Stephen P.

    1986-01-01

    The spectroscopic parameters and separations between the three low-lying X 3 Pi u, A 3 Sigma g -, and a 1 Sigma g + states of Al2 are studied as a function of both the one-particle and n-particle basis set. Approximate correlation treatments are calibrated against full Cl calculations correlating the six valence electrons in a double-zeta plus two d-function basis set. Since the CASSCF/MRCI 3 Pi u to 3 Sigma g - separation is in excellent agreement wtih the FCI value, the MRCI calculations were carried out in an extended (20s13p6d4f)/(6s5p3d2f) gaussian basis. Including a small correction for relativistic effects, the best estimate is that 3 Sigma g - state lies 174/cm above the 3 Pi u ground state. The 1 Sigma g + state lies at least 2000/cm higher in energy. At the CPF level, inclusion of 2s and 2p correlation has little effect on D sub e, reduces T sub e by only 26/cm, and shortens the bond lengths by about 0.02 a sub o. Further strong support for a 3 Pi u ground state comes from the experimental absorption spectra, since both observed transitions can be convincingly assigned as 3 Pi u yields 3 Pi g. The (2) 3 Pi g state is observed to be sensitive to the level of correlation treatment, and to have its minimum shifted to shorter rho values, such that the strongest experimental absorption peak probably corresponds to the 0 yields 2 transition.

  4. Talent in autism: hyper-systemizing, hyper-attention to detail and sensory hypersensitivity

    PubMed Central

    Baron-Cohen, Simon; Ashwin, Emma; Ashwin, Chris; Tavassoli, Teresa; Chakrabarti, Bhismadev

    2009-01-01

    We argue that hyper-systemizing predisposes individuals to show talent, and review evidence that hyper-systemizing is part of the cognitive style of people with autism spectrum conditions (ASC). We then clarify the hyper-systemizing theory, contrasting it to the weak central coherence (WCC) and executive dysfunction (ED) theories. The ED theory has difficulty explaining the existence of talent in ASC. While both hyper-systemizing and WCC theories postulate excellent attention to detail, by itself excellent attention to detail will not produce talent. By contrast, the hyper-systemizing theory argues that the excellent attention to detail is directed towards detecting ‘if p, then q’ rules (or [input–operation–output] reasoning). Such law-based pattern recognition systems can produce talent in systemizable domains. Finally, we argue that the excellent attention to detail in ASC is itself a consequence of sensory hypersensitivity. We review an experiment from our laboratory demonstrating sensory hypersensitivity detection thresholds in vision. We conclude that the origins of the association between autism and talent begin at the sensory level, include excellent attention to detail and end with hyper-systemizing. PMID:19528020

  5. Tests of a robust eddy correlation system for sensible heat flux

    NASA Astrophysics Data System (ADS)

    Blanford, J. H.; Gay, L. W.

    1992-03-01

    Sensible heat flux estimates from a simple, one-propeller eddy correlation system (OPEC) were compared with those from a sonic anemometer eddy correlation system (SEC). In accordance with similarity theory, the performance of the OPEC system improved with increasing height of the sensor above the surface. Flux totals from the two systems at sites with adequate fetch were in excellent agreement after frequency response corrections were applied. The propeller system appears suitable for long periods of unattended measurement. The sensible heat flux measurements can be combined with net radiation and soil heat flux measurements to estimate latent heat as a residual in the surface energy balance.

  6. Optimization of a hybrid exchange-correlation functional for silicon carbides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oda, Takuji; Zhang, Yanwen; Weber, William J

    2013-01-01

    A hybrid exchange-correlation functional is optimized in order to accurately describe the nature of silicon carbides (SiC) in the framework of ab-initio calculations based on density functional theory (DFT), especially with an aim toward future applications in defect studies. It is shown that the Heyd-Scuseria-Ernzerhof (HSE) hybrid functional with the screening parameter of 0.15 -1 outperforms conventional exchange-correlation functionals and other popular hybrid functionals regarding description of band structures in SiC. High transferability is proven through assessment over various SiC polytypes, silicon and diamond. Excellent performance is also confirmed for other fundamental material properties including elastic constants and phonon frequency.

  7. Evaluation of ERTS MSS digital data for monitoring water in the lower Chesapeake Bay area

    NASA Technical Reports Server (NTRS)

    Bowker, D. E.; Witte, W. G.

    1975-01-01

    Water samples collected during the ERTS overpasses of the lower Chesapeake Bay area have been analyzed for chlorophyll, particles, and sediment. Five ERTS images were sufficiently cloud free that a correlation analysis of radiance values from the MSS bands with the water parameters could be performed. A low correlation was established for chlorophyll, except during algal blooms, when band 6 was responsive. There was a fair to good correlation with particles for combinations of band 5, particularly bands (5 minus 6). Sediment correlations were excellent for band 5 or combinations of band 5 with bands 4 and 6. It was evident that such factors as the atmosphere, tide, and different water masses were tending to confuse the data.

  8. The Chemistry of MoS2 and Related Compounds and Their Applications in Electrocatalysis and Photoelectrochemistry

    NASA Astrophysics Data System (ADS)

    Ding, Qi

    The increasing energy demand in our society has stimulated intensive research in the development of sustainable and renewable energy sources to lessen our strong dependence on fossil fuels. Hydrogen is a clean, storable, and high-energy density energy carrier, and is a promising sustainable solution to achieve an environmentally friendly fuel economy. Electrochemical and solar-driven photoelectrochemical water splitting is regarded as one of the most promising approaches to utilize renewable energy to product hydrogen fuel, yet Pt remains the best electrocatalyst for hydrogen evolution reaction (HER), the high cost of which ultimately limit the scalability of such technologies. Layered transition metal dichalcogenides (TMDCs) is a family of compounds that has attracted widespread attention due to their broad range of applications in electronics, optoelectronics, sensing, energy storage, and catalysis. My research has primarily focused on understanding the chemistry of MoS2 and related compounds, and developing rational approaches to enable these materials for efficient electrocatalytic and photoelectrochemical (PEC) hydrogen evolution. We demonstrated highly efficient and robust photocathodes based on heterostructures of chemically exfoliated metallic 1T-MoS2 and planar p-type Si for PEC-HER. Photocurrents up to 17.6 mA/cm2 at 0 V vs reversible hydrogen electrode (RHE) were achieved under simulated 1 sun irradiation, and excellent stability was demonstrated over long-term operation. Building upon the 1T-MoS2 groundwork, amorphous ternary compounds MoQxCly (Q = S, Se) were then developed as excellent catalysts for HER. The preparation of MoQxCly requires much lower temperature and easier fabrication, yet the PEC performance of MoSxCly-based photocathode is even better than 1T-MoS2-based photocathode. Moreover, when MoSxCly is incorporated with n+pp+ Si micropyramids (MPs), we demonstrate the highest current density ever reported for Si-based photocathodes. Furthermore, to fully harness the potentials of MoS2 and utilize it for a broader range of applications, we demonstrate covalent functionalization on the basal plane of 2H-MoS2 via thiol conjugation, despite the general belief that the basal plane is too inert for functionalization. We correlate the degree of functionalization to the amount of sulfur vacancies on MoS2 basal plane, and successfully demonstrated the preparation of MoS2-PbSe quantum dot heterostructures using a bi-functional dithiol linker molecule.

  9. Pharmaceutical Market Access: current state of affairs and key challenges - results of the Market Access Launch Excellence Inventory (MALEI).

    PubMed

    Koch, Marcus A

    2015-01-01

    To take inventory of the current state of affairs of Market Access Launch Excellence in the life sciences industry. To identify key gaps and challenges for Market Access (MA) and discuss how they can be addressed. To generate a baseline for benchmarking MA launch excellence. An online survey was conducted with pharmaceutical executives primarily working in MA, marketing, or general management. The survey aimed to evaluate MA excellence prerequisites across the product life cycle (rated by importance and level of implementation) and to describe MA activity models in the respective companies. Composite scores were calculated from respondents' ratings and answers. Implementation levels of MA excellence prerequisites generally lagged behind their perceived importance. Item importance and the respective level of implementation correlated well, which can be interpreted as proof of the validity of the questionnaire. The following areas were shown to be particularly underimplemented: 1) early integration of MA and health economic considerations in research and development decision making, 2) developing true partnerships with payers, including the development of services 'beyond the pill', and 3) consideration of human resource and talent management. The concept of importance-adjusted implementation levels as a hybrid parameter was introduced and shown to be a viable tool for benchmarking purposes. More than 70% of respondents indicated that their companies will invest broadly in MA in terms of capital and headcount within the next 3 years. MA (launch) excellence needs to be further developed in order to close implementation gaps across the entire product life cycle. As MA is a comparatively young pharmaceutical discipline in a complex and dynamic environment, this effort will require strategic focus and dedication. The Market Access Launch Excellence Inventory benchmarking tool may help guide decision makers to prioritize their endeavors.

  10. Use of Metal Oxide Nanoparticle Band Gap to Develop a Predictive Paradigm for Oxidative Stress and Acute Pulmonary Inflammation

    PubMed Central

    Zhang, Haiyuan; Ji, Zhaoxia; Xia, Tian; Meng, Huan; Low-Kam, Cecile; Liu, Rong; Pokhrel, Suman; Lin, Sijie; Wang, Xiang; Liao, Yu-Pei; Wang, Meiying; Li, Linjiang; Rallo, Robert; Damoiseaux, Robert; Telesca, Donatello; Mädler, Lutz; Cohen, Yoram; Zink, Jeffrey I.; Nel, Andre E.

    2014-01-01

    We demonstrate for 24 metal oxide (MOx) nanoparticles that it is possible to use conduction band energy levels to delineate their toxicological potential at cellular and whole animal levels. Among the materials, the overlap of conduction band energy (Ec) levels with the cellular redox potential (−4.12 to −4.84 eV) was strongly correlated to the ability of Co3O4, Cr2O3, Ni2O3, Mn2O3 and CoO nanoparticles to induce oxygen radicals, oxidative stress and inflammation. This outcome is premised on permissible electron transfers from the biological redox couples that maintain the cellular redox equilibrium to the conduction band of the semiconductor particles. Both single parameter cytotoxic as well as multi-parameter oxidative stress assays in cells showed excellent correlation to the generation of acute neutrophilic inflammation and cytokine responses in the lungs of CB57 Bl/6 mice. Co3O4, Ni2O3, Mn2O3 and CoO nanoparticles could also oxidize cytochrome c as a representative redox couple involved in redox homeostasis. While CuO and ZnO generated oxidative stress and acute pulmonary inflammation that is not predicted by Ec levels, the adverse biological effects of these materials could be explained by their solubility, as demonstrated by ICP-MS analysis. Taken together, these results demonstrate, for the first time, that it is possible to predict the toxicity of a large series of MOx nanoparticles in the lung premised on semiconductor properties and an integrated in vitro/in vivo hazard ranking model premised on oxidative stress. This establishes a robust platform for modeling of MOx structure-activity relationships based on band gap energy levels and particle dissolution. This predictive toxicological paradigm is also of considerable importance for regulatory decision-making about this important class of engineered nanomaterials. PMID:22502734

  11. Use of metal oxide nanoparticle band gap to develop a predictive paradigm for oxidative stress and acute pulmonary inflammation.

    PubMed

    Zhang, Haiyuan; Ji, Zhaoxia; Xia, Tian; Meng, Huan; Low-Kam, Cecile; Liu, Rong; Pokhrel, Suman; Lin, Sijie; Wang, Xiang; Liao, Yu-Pei; Wang, Meiying; Li, Linjiang; Rallo, Robert; Damoiseaux, Robert; Telesca, Donatello; Mädler, Lutz; Cohen, Yoram; Zink, Jeffrey I; Nel, Andre E

    2012-05-22

    We demonstrate for 24 metal oxide (MOx) nanoparticles that it is possible to use conduction band energy levels to delineate their toxicological potential at cellular and whole animal levels. Among the materials, the overlap of conduction band energy (E(c)) levels with the cellular redox potential (-4.12 to -4.84 eV) was strongly correlated to the ability of Co(3)O(4), Cr(2)O(3), Ni(2)O(3), Mn(2)O(3), and CoO nanoparticles to induce oxygen radicals, oxidative stress, and inflammation. This outcome is premised on permissible electron transfers from the biological redox couples that maintain the cellular redox equilibrium to the conduction band of the semiconductor particles. Both single-parameter cytotoxic as well as multi-parameter oxidative stress assays in cells showed excellent correlation to the generation of acute neutrophilic inflammation and cytokine responses in the lungs of C57 BL/6 mice. Co(3)O(4), Ni(2)O(3), Mn(2)O(3), and CoO nanoparticles could also oxidize cytochrome c as a representative redox couple involved in redox homeostasis. While CuO and ZnO generated oxidative stress and acute pulmonary inflammation that is not predicted by E(c) levels, the adverse biological effects of these materials could be explained by their solubility, as demonstrated by ICP-MS analysis. These results demonstrate that it is possible to predict the toxicity of a large series of MOx nanoparticles in the lung premised on semiconductor properties and an integrated in vitro/in vivo hazard ranking model premised on oxidative stress. This establishes a robust platform for modeling of MOx structure-activity relationships based on band gap energy levels and particle dissolution. This predictive toxicological paradigm is also of considerable importance for regulatory decision-making about this important class of engineered nanomaterials.

  12. Joint multifractal analysis based on the partition function approach: analytical analysis, numerical simulation and empirical application

    NASA Astrophysics Data System (ADS)

    Xie, Wen-Jie; Jiang, Zhi-Qiang; Gu, Gao-Feng; Xiong, Xiong; Zhou, Wei-Xing

    2015-10-01

    Many complex systems generate multifractal time series which are long-range cross-correlated. Numerous methods have been proposed to characterize the multifractal nature of these long-range cross correlations. However, several important issues about these methods are not well understood and most methods consider only one moment order. We study the joint multifractal analysis based on partition function with two moment orders, which was initially invented to investigate fluid fields, and derive analytically several important properties. We apply the method numerically to binomial measures with multifractal cross correlations and bivariate fractional Brownian motions without multifractal cross correlations. For binomial multifractal measures, the explicit expressions of mass function, singularity strength and multifractal spectrum of the cross correlations are derived, which agree excellently with the numerical results. We also apply the method to stock market indexes and unveil intriguing multifractality in the cross correlations of index volatilities.

  13. Correlating Diversity Success with Academic Success

    ERIC Educational Resources Information Center

    Ibram, Rogers

    2008-01-01

    Texas A&M University's Laboratory for Diversity in Sport and the National Collegiate Athletic Association (NCAA) have partnered to honor those athletic programs that are best championing diversity. A total of 162 Diversity in Athletics Awards are being given in eight categories, including overall excellence in diversity. The NCAA granted Texas…

  14. Effects of Gender, Mathematics Anxiety and Achievement Motivation on College Students' Achievement in Mathematics

    ERIC Educational Resources Information Center

    Ajogbeje, Oke James; Borisade, Fidelis Tunde; Aladesaye, Charles Ademuyiwa; Ayodele, Oludolapo Bolanle

    2013-01-01

    The urge to excel or perform maximally in mathematics varies from individual to individual because achievement motivation is often developed or learnt during socialization and learning experiences. The study examined the relationship between College of Education students' achievement motivation and mathematics achievement, correlation coefficient…

  15. The physics of ice cream

    NASA Astrophysics Data System (ADS)

    Clarke, Chris

    2003-05-01

    Almost everybody likes ice cream, so it can provide an excellent vehicle for discussing and demonstrating a variety of physical phenomena, such as Newton's law of cooling, Boyle's law and the relationship between microstructure and macroscopic properties (e.g. Young's modulus). Furthermore, a demonstration of freezing point depression can be used to make ice cream in the classroom!

  16. Impact of Non-Suicidal Self-Injury Scale: Initial Psychometric Validation

    PubMed Central

    Burke, Taylor A.; Ammerman, Brooke A.; Hamilton, Jessica L.; Alloy, Lauren B.

    2017-01-01

    The current study examined the psychometric properties of the Impact of Non-Suicidal Self-Injury Scale (INS), a scale developed to assess the social, behavioral, and emotional consequences of engaging in non-suicidal self-injury (NSSI). University students (N=128) who endorsed a history of NSSI were administered the INS, as well as measures of hypothesized convergent and divergent validity. Results suggested that the INS is best conceptualized as a one-factor scale, and internal consistency analyses indicated excellent reliability. The INS was significantly correlated with well-known measures of NSSI severity (i.e., NSSI frequency, NSSI recency), and measures of suicide attempt history and emotional reactivity. Logistic regression analyses indicated that the INS contributed unique variance to the prediction of physical disfigurement (i.e., NSSI scarring) and clinically significant social anxiety, even after taking into account NSSI frequency. Furthermore, the INS demonstrated divergent validity. Implications for research on NSSI disorder and clinical practice are discussed. PMID:28824214

  17. Malignant external otitis: the role of computed tomography and radionuclides in evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendelson, D.S.; Som, P.M.; Mendelson, M.H.

    1983-12-01

    Nine patients with malignant external otitis (MEO) were evaluated with Tc-99m bone scans, Ga-67 citrate scans, pluridirectional tomography, and computed tomographic (CT) scans in order to assess the role of each in the diagnosis and management of MEO. The Tc-99m and Ga-67 citrate scans were the most accurate studies in the initial identification of disease activity, while the return to normal or improvement of the Ga-67 citrate scan has been shown to correlate best with clinical resolution of MEO. CT demonstrated soft-tissue disease and central skull base osteomyelitis better than pluridirectional tomography. CT is excellent for localizing and following themore » progression of bone disease; however, because reossification of the skull base is a very slow process, CT cannot be used to follow accurately regression or inactivity of MEO affecting this area. CT is the best modality for following soft-tissue extension of MEO.« less

  18. Reliability and validity of a treatment fidelity assessment for motivational interviewing targeting sexual risk behaviors in people living with HIV/AIDS.

    PubMed

    Seng, Elizabeth K; Lovejoy, Travis I

    2013-12-01

    This study psychometrically evaluates the Motivational Interviewing Treatment Integrity Code (MITI) to assess fidelity to motivational interviewing to reduce sexual risk behaviors in people living with HIV/AIDS. 74 sessions from a pilot randomized controlled trial of motivational interviewing to reduce sexual risk behaviors in people living with HIV were coded with the MITI. Participants reported sexual behavior at baseline, 3-month, and 6-months. Regarding reliability, excellent inter-rater reliability was achieved for measures of behavior frequency across the 12 sessions coded by both coders; global scales demonstrated poor intraclass correlations, but adequate percent agreement. Regarding validity, principle components analyses indicated that a two-factor model accounted for an adequate amount of variance in the data. These factors were associated with decreases in sexual risk behaviors after treatment. The MITI is a reliable and valid measurement of treatment fidelity for motivational interviewing targeting sexual risk behaviors in people living with HIV/AIDS.

  19. A semi-automatic method for left ventricle volume estimate: an in vivo validation study

    NASA Technical Reports Server (NTRS)

    Corsi, C.; Lamberti, C.; Sarti, A.; Saracino, G.; Shiota, T.; Thomas, J. D.

    2001-01-01

    This study aims to the validation of the left ventricular (LV) volume estimates obtained by processing volumetric data utilizing a segmentation model based on level set technique. The validation has been performed by comparing real-time volumetric echo data (RT3DE) and magnetic resonance (MRI) data. A validation protocol has been defined. The validation protocol was applied to twenty-four estimates (range 61-467 ml) obtained from normal and pathologic subjects, which underwent both RT3DE and MRI. A statistical analysis was performed on each estimate and on clinical parameters as stroke volume (SV) and ejection fraction (EF). Assuming MRI estimates (x) as a reference, an excellent correlation was found with volume measured by utilizing the segmentation procedure (y) (y=0.89x + 13.78, r=0.98). The mean error on SV was 8 ml and the mean error on EF was 2%. This study demonstrated that the segmentation technique is reliably applicable on human hearts in clinical practice.

  20. Reliability of a Novel Social Activity Questionnaire: Perceived Social Support and Verbal Interaction in the Wisconsin Registry for Alzheimer's Prevention.

    PubMed

    Zuelsdorff, Megan L; Koscik, Rebecca L; Okonkwo, Ozioma C; Peppard, Paul E; Hermann, Bruce P; Sager, Mark A; Johnson, Sterling C; Engelman, Corinne D

    2018-02-01

    Social activity is associated with healthy aging and preserved cognition. Such activity includes a confluence of social support and verbal interaction, each influencing cognition through rarely parsed, mechanistically distinct pathways. We created a novel verbal interaction measure for the Wisconsin Registry for Alzheimer's Prevention (WRAP) and assessed reliability of resultant data, a first step toward mechanism-driven examination of social activity as a modifiable predictor of cognitive health. Two WRAP subsamples completed a test-retest study to determine 8-week stability ( n = 107) and 2-year stability ( n = 136) of verbal interaction, and 2-year stability of perceived social support. Reliability was determined using quadratic-weighted kappa, percent agreement, or correlation coefficients. Reliability was fair to almost perfect. The association between social support and interaction quantity decreased with age. Social activity data demonstrate moderate to excellent temporal stability. Moreover, in older individuals, social support and verbal interaction represent two distinct dimensions of social activity.

  1. Mushrooms: A rich source of the antioxidants ergothioneine and glutathione.

    PubMed

    Kalaras, Michael D; Richie, John P; Calcagnotto, Ana; Beelman, Robert B

    2017-10-15

    While mushrooms are the highest dietary source for the unique sulfur-containing antioxidant ergothioneine, little is known regarding levels of the major biological antioxidant glutathione. Thus, our objectives were to determine and compare levels of glutathione, as well as ergothioneine, in different species of mushrooms. Glutathione levels varied >20-fold (0.11-2.41mg/gdw) with some varieties having higher levels than reported for other foods. Ergothioneine levels also varied widely (0.15-7.27mg/gdw) and were highly correlated with those of glutathione (r=0.62, P<0.001). Both antioxidants were more concentrated in pileus than stipe tissues in selected mushrooms species. Agaricus bisporus harvested during the third cropping flush contained higher levels of ergothioneine and glutathione compared to the first flush, possibly as a response to increased oxidative stress. This study demonstrated that certain mushroom species are high in glutathione and ergothioneine and should be considered an excellent dietary source of these important antioxidants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Corrosion Performance of New Generation Aluminum-Lithium Alloys for Aerospace Applications

    NASA Astrophysics Data System (ADS)

    Moran, James P.; Bovard, Francine S.; Chrzan, James D.; Vandenburgh, Peter

    Over the past several years, a new generation of aluminum-lithium alloys has been developed. These alloys are characterized by excellent strength, low density, and high modulus of elasticity and are therefore of interest for lightweight structural materials applications particularly for construction of current and future aircraft. These new alloys have also demonstrated significant improvements in corrosion resistance when compared with the legacy and incumbent alloys. This paper documents the superior corrosion resistance of the current commercial tempers of these materials and also discusses the corrosion performance as a function of the degree of artificial aging. Results from laboratory corrosion tests are compared with results from exposures in a seacoast atmosphere to assess the predictive capability of the laboratory tests. The correlations that have been developed between the laboratory tests and the seacoast exposures provide confidence that a set of available methods can provide an accurate assessment of the corrosion performance of this new generation of alloys.

  3. Direct identification of metallic and semiconducting single-walled carbon nanotubes in scanning electron microscopy.

    PubMed

    Li, Jie; He, Yujun; Han, Yimo; Liu, Kai; Wang, Jiaping; Li, Qunqing; Fan, Shoushan; Jiang, Kaili

    2012-08-08

    Because of their excellent electrical and optical properties, carbon nanotubes have been regarded as extremely promising candidates for high-performance electronic and optoelectronic applications. However, effective and efficient distinction and separation of metallic and semiconducting single-walled carbon nanotubes are always challenges for their practical applications. Here we show that metallic and semiconducting single-walled carbon nanotubes on SiO(2) can have obviously different contrast in scanning electron microscopy due to their conductivity difference and thus can be effectively and efficiently identified. The correlation between conductivity and contrast difference has been confirmed by using voltage-contrast scanning electron microcopy, peak force tunneling atom force microscopy, and field effect transistor testing. This phenomenon can be understood via a proposed mechanism involving the e-beam-induced surface potential of insulators and the conductivity difference between metallic and semiconducting SWCNTs. This method demonstrates great promise to achieve rapid and large-scale distinguishing between metallic and semiconducting single-walled carbon nanotubes, adding a new function to conventional SEM.

  4. Classical density-functional theory of inhomogeneous water including explicit molecular structure and nonlinear dielectric response.

    PubMed

    Lischner, Johannes; Arias, T A

    2010-02-11

    We present an accurate free-energy functional for liquid water written in terms of a set of effective potential fields in which fictitious noninteracting water molecules move. The functional contains an exact expression of the entropy of noninteracting molecules and thus provides an ideal starting point for the inclusion of complex intermolecular interactions which depend on the orientation of the interacting molecules. We show how an excess free-energy functional can be constructed to reproduce the following properties of water: the dielectric response; the experimental site-site correlation functions; the surface tension; the bulk modulus of the liquid and the variation of this modulus with pressure; the density of the liquid and the vapor phase; and liquid-vapor coexistence. As a demonstration, we present results for the application of this theory to the behavior of liquid water in a parallel plate capacitor. In particular, we make predictions for the dielectric response of water in the nonlinear regime, finding excellent agreement with known data.

  5. New Method To Estimate Total Polyphenol Excretion: Comparison of Fast Blue BB versus Folin-Ciocalteu Performance in Urine.

    PubMed

    Hinojosa-Nogueira, Daniel; Muros, Joaquín; Rufián-Henares, José A; Pastoriza, Silvia

    2017-05-24

    Polyphenols are bioactive substances of vegetal origin with a significant impact on human health. The assessment of polyphenol intake and excretion is therefore important. The Folin-Ciocalteu (F-C) method is the reference assay to measure polyphenols in foods as well as their excretion in urine. However, many substances can influence the method, making it necessary to conduct a prior cleanup using solid-phase extraction (SPE) cartridges. In this paper, we demonstrate the use of the Fast Blue BB reagent (FBBB) as a new tool to measure the excretion of polyphenols in urine. Contrary to F-C, FBBB showed no interference in urine, negating the time-consuming and costly SPE cleanup. In addition, it showed excellent linearity (r 2 = 0.9997), with a recovery of 96.4% and a precision of 1.86-2.11%. The FBBB method was validated to measure the excretion of polyphenols in spot urine samples from Spanish children, showing a good correlation between polyphenol intake and excretion.

  6. Nonempirical Semilocal Free-Energy Density Functional for Matter under Extreme Conditions.

    PubMed

    Karasiev, Valentin V; Dufty, James W; Trickey, S B

    2018-02-16

    Realizing the potential for predictive density functional calculations of matter under extreme conditions depends crucially upon having an exchange-correlation (XC) free-energy functional accurate over a wide range of state conditions. Unlike the ground-state case, no such functional exists. We remedy that with systematic construction of a generalized gradient approximation XC free-energy functional based on rigorous constraints, including the free-energy gradient expansion. The new functional provides the correct temperature dependence in the slowly varying regime and the correct zero-T, high-T, and homogeneous electron gas limits. Its accuracy in the warm dense matter regime is attested by excellent agreement of the calculated deuterium equation of state with reference path integral Monte Carlo results at intermediate and elevated T. Pressure shifts for hot electrons in compressed static fcc Al and for low-density Al demonstrate the combined magnitude of thermal and gradient effects handled well by this functional over a wide T range.

  7. Glymphatic clearance controls state-dependent changes in brain lactate concentration.

    PubMed

    Lundgaard, Iben; Lu, Minh Lon; Yang, Ezra; Peng, Weiguo; Mestre, Humberto; Hitomi, Emi; Deane, Rashid; Nedergaard, Maiken

    2017-06-01

    Brain lactate concentration is higher during wakefulness than in sleep. However, it is unknown why arousal is linked to an increase in brain lactate and why lactate declines within minutes of sleep. Here, we show that the glymphatic system is responsible for state-dependent changes in brain lactate concentration. Suppression of glymphatic function via acetazolamide treatment, cisterna magna puncture, aquaporin 4 deletion, or changes in body position reduced the decline in brain lactate normally observed when awake mice transition into sleep or anesthesia. Concurrently, the same manipulations diminished accumulation of lactate in cervical, but not in inguinal lymph nodes when mice were anesthetized. Thus, our study suggests that brain lactate is an excellent biomarker of the sleep-wake cycle and increases further during sleep deprivation, because brain lactate is inversely correlated with glymphatic-lymphatic clearance. This analysis provides fundamental new insight into brain energy metabolism by demonstrating that glucose that is not fully oxidized can be exported as lactate via glymphatic-lymphatic fluid transport.

  8. Quantification of Finger-Tapping Angle Based on Wearable Sensors

    PubMed Central

    Djurić-Jovičić, Milica; Jovičić, Nenad S.; Roby-Brami, Agnes; Popović, Mirjana B.; Kostić, Vladimir S.; Djordjević, Antonije R.

    2017-01-01

    We propose a novel simple method for quantitative and qualitative finger-tapping assessment based on miniature inertial sensors (3D gyroscopes) placed on the thumb and index-finger. We propose a simplified description of the finger tapping by using a single angle, describing rotation around a dominant axis. The method was verified on twelve subjects, who performed various tapping tasks, mimicking impaired patterns. The obtained tapping angles were compared with results of a motion capture camera system, demonstrating excellent accuracy. The root-mean-square (RMS) error between the two sets of data is, on average, below 4°, and the intraclass correlation coefficient is, on average, greater than 0.972. Data obtained by the proposed method may be used together with scores from clinical tests to enable a better diagnostic. Along with hardware simplicity, this makes the proposed method a promising candidate for use in clinical practice. Furthermore, our definition of the tapping angle can be applied to all tapping assessment systems. PMID:28125051

  9. Quantification of Finger-Tapping Angle Based on Wearable Sensors.

    PubMed

    Djurić-Jovičić, Milica; Jovičić, Nenad S; Roby-Brami, Agnes; Popović, Mirjana B; Kostić, Vladimir S; Djordjević, Antonije R

    2017-01-25

    We propose a novel simple method for quantitative and qualitative finger-tapping assessment based on miniature inertial sensors (3D gyroscopes) placed on the thumb and index-finger. We propose a simplified description of the finger tapping by using a single angle, describing rotation around a dominant axis. The method was verified on twelve subjects, who performed various tapping tasks, mimicking impaired patterns. The obtained tapping angles were compared with results of a motion capture camera system, demonstrating excellent accuracy. The root-mean-square (RMS) error between the two sets of data is, on average, below 4°, and the intraclass correlation coefficient is, on average, greater than 0.972. Data obtained by the proposed method may be used together with scores from clinical tests to enable a better diagnostic. Along with hardware simplicity, this makes the proposed method a promising candidate for use in clinical practice. Furthermore, our definition of the tapping angle can be applied to all tapping assessment systems.

  10. Calculation of Hammett Equation parameters for some N,N‧-bis (substituted-phenyl)-1,4-quinonediimines by density functional theory

    NASA Astrophysics Data System (ADS)

    Sein, Lawrence T.

    2011-08-01

    Hammett parameters σ' were determined from vertical ionization potentials, vertical electron affinities, adiabatic ionization potentials, adiabatic electron affinities, HOMO, and LUMO energies of a series of N, N' -bis (3',4'-substituted-phenyl)-1,4-quinonediimines computed at the B3LYP/6-311+G(2d,p) level on B3LYP/6-31G ∗ molecular geometries. These parameters were then least squares fit as a function of literature Hammett parameters. For N, N' -bis (4'-substituted-phenyl)-1,4-quinonediimines, the least squares fits demonstrated excellent linearity, with the square of Pearson's correlation coefficient ( r2) greater than 0.98 for all isomers. For N, N' -bis (3'-substituted-3'-aminophenyl)-1,4-quinonediimines, the least squares fits were less nearly linear, with r2 approximately 0.70 for all isomers when derived from calculated vertical ionization potentials, but those from calculated vertical electron affinities usually greater than 0.90.

  11. Bridging the gap between research into biological and psychosocial models of psychosis.

    PubMed

    Murray, Robin M; Sideli, Lucia; LA Cascia, Caterina; LA Barbera, Daniele

    2015-06-25

    Paul Bebbington's recent Special Article provides an excellent synthesis of recent advances in psychosocial research on psychosis. However, we doubt that a model based solely on social epidemiology and cognitive theory can totally describe psychosis, and to be fair, Bebbington does not suggest that it does. A complete model must also incorporate what we have learned from non-social epidemiology, neuroscience, and genetics. Evidence indicates that both the social risk factors that interest Bebbington and biological risk factors, such as abuse of stimulants and cannabis, can provoke psychotic symptoms by dysregulating striatal dopamine. The role of neurodevelopmental deviance also needs to be considered in the etiology of schizophrenia-like psychosis. Moreover, the striking advances in our understanding of the genetic architecture of psychosis open an exciting door into studies examining gene-environment correlation and gene-environment interaction. In short, Bebbington demonstrates the value of cognitive and social researchers talking to each other, but the occasional chat with the more biologically inclined could produce a more comprehensive model.

  12. Reference values for the muscle power sprint test in 6- to 12-year-old children.

    PubMed

    Douma-van Riet, Danielle; Verschuren, Olaf; Jelsma, Dorothee; Kruitwagen, Cas; Smits-Engelsman, Bouwien; Takken, Tim

    2012-01-01

    The aims of this study were (1) to develop centile reference values for anaerobic performance of Dutch children tested using the Muscle Power Sprint Test (MPST) and (2) to examine the test-retest reliability of the MPST. Children who were developing typically (178 boys and 201 girls) and aged 6 to 12 years (mean = 8.9 years) were recruited. The MPST was administered to 379 children, and test-retest reliability was examined in 47 children. MPST scores were transformed into centile curves, which were created using generalized additive models for location, scale, and shape. Height-related reference curves were created for both genders. Excellent (intraclass correlation coefficient = 0.98) test-retest reliability was demonstrated. The reference values for the MPST of children who are developing typically and aged 6 to 12 years can serve as a clinical standard in pediatric physical therapy practice. The MPST is a reliable and practical method for determining anaerobic performance in children.

  13. Label-free nanoplasmonic sensing of tumor-associate autoantibodies for early diagnosis of colorectal cancer.

    PubMed

    Soler, Maria; Estevez, M-Carmen; Villar-Vazquez, Roi; Casal, J Ignacio; Lechuga, Laura M

    2016-08-03

    Colorectal cancer is treatable and curable when detected at early stages. However there is a lack of less invasive and more specific screening and diagnosis methods which would facilitate its prompt identification. Blood circulating autoantibodies which are immediately produced by the immune system at tumor appearance have become valuable biomarkers for preclinical diagnosis of cancer. In this work, we present the rapid and label-free detection of colorectal cancer autoantibodies directly in blood serum or plasma using a recently developed nanoplasmonic biosensor. Our nanoplasmonic device offers sensitive and real-time quantification of autoantibodies with excellent selectivity and reproducibility, achieving limits of detection around 1 nM (150-160 ng mL(-1)). A preliminary evaluation of clinical samples of colorectal cancer patients has shown good correlation with ELISA. These results demonstrate the reliability of the nanobiosensor strategy and pave the way towards the achievement of a sensitive diagnostic tool for early detection of colorectal cancer. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Functional improvements in dried egg white through the Maillard reaction.

    PubMed

    Handa, A; Kuroda, N

    1999-05-01

    The effects of the Maillard reaction on the functional properties of dried egg white (DEW) were investigated. Maillard-reacted DEW (M-DEW) was prepared by storing sugar-preserved DEW (SP-DEW) at 55 degrees C and 35% relative humidity for 0-12 days. The M-DEW developed an excellent gelling property, and hydrogen sulfide production from heat-induced M-DEW gels decreased. Surface sulfhydryl (SH) group content of M-DEW increased while total SH group and alpha-helix contents decreased with increasing heating time in the dry state. Breaking strength, breaking strain, water-holding capacity, and hydrogen sulfide of heat-induced M-DEW gels significantly correlated with surface and total SH group contents in M-DEW. SDS-PAGE revealed that M-DEW proteins were polymerized in which covalent bonds were involved. The present study demonstrated that the Maillard reaction partially unfolds and polymerizes proteins of SP-DEW and, consequently, improved gelling property of SP-DEW under certain controlled conditions.

  15. Glymphatic clearance controls state-dependent changes in brain lactate concentration

    PubMed Central

    Lu, Minh Lon; Yang, Ezra; Peng, Weiguo; Mestre, Humberto; Hitomi, Emi; Deane, Rashid; Nedergaard, Maiken

    2016-01-01

    Brain lactate concentration is higher during wakefulness than in sleep. However, it is unknown why arousal is linked to an increase in brain lactate and why lactate declines within minutes of sleep. Here, we show that the glymphatic system is responsible for state-dependent changes in brain lactate concentration. Suppression of glymphatic function via acetazolamide treatment, cisterna magna puncture, aquaporin 4 deletion, or changes in body position reduced the decline in brain lactate normally observed when awake mice transition into sleep or anesthesia. Concurrently, the same manipulations diminished accumulation of lactate in cervical, but not in inguinal lymph nodes when mice were anesthetized. Thus, our study suggests that brain lactate is an excellent biomarker of the sleep–wake cycle and increases further during sleep deprivation, because brain lactate is inversely correlated with glymphatic-lymphatic clearance. This analysis provides fundamental new insight into brain energy metabolism by demonstrating that glucose that is not fully oxidized can be exported as lactate via glymphatic-lymphatic fluid transport. PMID:27481936

  16. Semilocal Exchange Energy Functional for Two-Dimensional Quantum Systems: A Step Beyond Generalized Gradient Approximations.

    PubMed

    Jana, Subrata; Samal, Prasanjit

    2017-06-29

    Semilocal density functionals for the exchange-correlation energy of electrons are extensively used as they produce realistic and accurate results for finite and extended systems. The choice of techniques plays a crucial role in constructing such functionals of improved accuracy and efficiency. An accurate and efficient semilocal exchange energy functional in two dimensions is constructed by making use of the corresponding hole which is derived based on the density matrix expansion. The exchange hole involved is localized under the generalized coordinate transformation and satisfies all the relevant constraints. Comprehensive testing and excellent performance of the functional is demonstrated versus exact exchange results. The accuracy of results obtained by using the newly constructed functional is quite remarkable as it substantially reduces the errors present in the local and nonempirical exchange functionals proposed so far for two-dimensional quantum systems. The underlying principles involved in the functional construction are physically appealing and hold promise for developing range separated and nonlocal exchange functionals in two dimensions.

  17. A novel indirect ELISA based on glycoprotein Gn for the detection of IgG antibodies against Rift Valley fever virus in small ruminants.

    PubMed

    Jäckel, S; Eiden, M; Balkema-Buschmann, A; Ziller, M; van Vuren, P Jansen; Paweska, J T; Groschup, M H

    2013-10-01

    Rift Valley fever virus (RVFV) is an emerging zoonotic pathogen that causes high morbidity and mortality in humans and livestock. In this paper, we describe the cloning, expression and purification of RVFV glycoprotein Gn and its application as a diagnostic antigen in an indirect ELISA for the specific detection of RVF IgG antibodies in sheep and goats. The performance of this Gn based ELISA is validated using a panel of almost 2000 field samples from sheep and goats from Mozambique, Senegal, Uganda and Yemen. All serum samples were also tested by virus neutralization test (VNT), the gold standard method for RVFV serological testing. Compared to the VNT results the Gn based ELISA proved to have an excellent sensitivity (94.56%) and specificity (95.57%). Apart from establishing this new diagnostic assay, these results also demonstrate a close correlation between the presence of RVFV Gn and neutralizing antibodies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Nonempirical Semilocal Free-Energy Density Functional for Matter under Extreme Conditions

    NASA Astrophysics Data System (ADS)

    Karasiev, Valentin V.; Dufty, James W.; Trickey, S. B.

    2018-02-01

    Realizing the potential for predictive density functional calculations of matter under extreme conditions depends crucially upon having an exchange-correlation (X C ) free-energy functional accurate over a wide range of state conditions. Unlike the ground-state case, no such functional exists. We remedy that with systematic construction of a generalized gradient approximation X C free-energy functional based on rigorous constraints, including the free-energy gradient expansion. The new functional provides the correct temperature dependence in the slowly varying regime and the correct zero-T , high-T , and homogeneous electron gas limits. Its accuracy in the warm dense matter regime is attested by excellent agreement of the calculated deuterium equation of state with reference path integral Monte Carlo results at intermediate and elevated T . Pressure shifts for hot electrons in compressed static fcc Al and for low-density Al demonstrate the combined magnitude of thermal and gradient effects handled well by this functional over a wide T range.

  19. DNA Encapsulation of Ten Silver Atoms Produces a Bright, Modulatable, Near Infrared-Emitting Cluster

    PubMed Central

    Petty, Jeffrey T.; Fan, Chaoyang; Story, Sandra P.; Sengupta, Bidisha; Iyer, Ashlee St. John; Prudowsky, Zachary; Dickson, Robert M.

    2010-01-01

    Photostability, inherent fluorescence brightness, and optical modulation of fluorescence are key attributes distinguishing silver nanoclusters as fluorophores. DNA plays a central role both by protecting the clusters in aqueous environments and by directing their formation. Herein, we characterize a new near infrared-emitting cluster with excitation and emission maxima at 750 and 810 nm, respectively that is stabilized within C3AC3AC3TC3A. Following chromatographic resolution of the near infrared species, a stoichiometry of 10 Ag/oligonucleotide was determined. Combined with excellent photostability, the cluster’s 30% fluorescence quantum yield and 180,000 M−1cm−1 extinction coefficient give it a fluorescence brightness that significantly improves on that of the organic dye Cy7. Fluorescence correlation analysis shows an optically accessible dark state that can be directly depopulated with longer wavelength co-illumination. The coupled increase in total fluorescence demonstrates that enhanced sensitivity can be realized through Synchronously Amplified Fluorescence Image Recovery (SAFIRe), which further differentiates this new fluorophore. PMID:21116486

  20. Microstructure and mechanical properties of Ni and Fe-base boride-dispersion-strengthened microcrystalline alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wade, C.S.; Park, H.G.; Hoagland, R.G.

    This paper considers the relation between microstructure and mechanical properties of two Ni-base and two Fe-base Boride-Dispersion-Strengthened Microcrystalline (BDSM) alloys. In these very fine grained materials the borides were primarily Cr, Mo, and MoFe in a fcc matrix in three of the alloys, and a bcc in one of the Fe-base alloys. Strength data and resistance to stress corrosion cracking are reported and, in the latter case, extraordinary resistance to SCC in NaCl, Na{sub 2}S{sub 2}O{sub 3} and boiling MgCl{sub 2} environments was observed in every case. The fcc BDSM alloys also demonstrated excellent thermal stability in terms of strengthmore » and fracture roughness up to 1000 C. The bcc alloy suffered severe loss of toughness. The fracture mode involved ductile rupture in all alloys and they display a reasonably linear correlation between K{sub Ic} and the square root of particle spacing.« less

  1. Validity and reliability of a new tool to evaluate handwriting difficulties in Parkinson's disease.

    PubMed

    Nackaerts, Evelien; Heremans, Elke; Smits-Engelsman, Bouwien C M; Broeder, Sanne; Vandenberghe, Wim; Bergmans, Bruno; Nieuwboer, Alice

    2017-01-01

    Handwriting in Parkinson's disease (PD) features specific abnormalities which are difficult to assess in clinical practice since no specific tool for evaluation of spontaneous movement is currently available. This study aims to validate the 'Systematic Screening of Handwriting Difficulties' (SOS-test) in patients with PD. Handwriting performance of 87 patients and 26 healthy age-matched controls was examined using the SOS-test. Sixty-seven patients were tested a second time within a period of one month. Participants were asked to copy as much as possible of a text within 5 minutes with the instruction to write as neatly and quickly as in daily life. Writing speed (letters in 5 minutes), size (mm) and quality of handwriting were compared. Correlation analysis was performed between SOS outcomes and other fine motor skill measurements and disease characteristics. Intrarater, interrater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Spearman correlation coefficient. Patients with PD had a smaller (p = 0.043) and slower (p<0.001) handwriting and showed worse writing quality (p = 0.031) compared to controls. The outcomes of the SOS-test significantly correlated with fine motor skill performance and disease duration and severity. Furthermore, the test showed excellent intrarater, interrater and test-retest reliability (ICC > 0.769 for both groups). The SOS-test is a short and effective tool to detect handwriting problems in PD with excellent reliability. It can therefore be recommended as a clinical instrument for standardized screening of handwriting deficits in PD.

  2. Validation of the Balance Board for Clinical Evaluation of Balance During Serious Gaming Rehabilitation Exercises.

    PubMed

    Bonnechère, Bruno; Jansen, Bart; Omelina, Lubos; Sholukha, Victor; Van Sint Jan, Serge

    2016-09-01

    Balance and posture can be affected in various conditions or become decreased with aging. A diminution of balance control induces an increase of fall's risk. The Nintendo Wii Balance Board™ (WBB) is used in rehabilitation to perform balance exercises (using commercial video games). The WBB has also been validated to assess balance and posture in static conditions. However, there is currently no study investigating the use of WBB to assess balance during the realization of balance exercises using this device. The aim of this study was to validate the use of WBB, coupled with specially developed serious games, to assess dynamic balance during rehabilitation exercises. Thirty five subjects participated in this study. Subjects were asked to play two specially developed serious games. Center of pressure (CP) displacements were simultaneously recorded with a WBB and a gold standard force plate (FP). Nine parameters were derived from CP displacement. Bland and Altman plots, paired-sample t tests, intraclass correlation coefficient's, and Pearson's coefficient correlations were computed. Excellent correlation between both devices was found for each parameter for the two games (R = 0.95 and 0.96). Unlike previous work on the WBB, these excellent results were obtained without using any calibration procedure. Despite this, results were highly correlated between the WBB and the FP. The WBB could be used in clinics to assess balance during rehabilitation exercises and, thus, allows a more regular patient follow-up.

  3. Three-dimensional ultrasonography of the breast; An adequate replacement for MRI in neoadjuvant chemotherapy tumour response evaluation? - RESPONDER trial.

    PubMed

    van Egdom, L S E; Lagendijk, M; Heijkoop, E H M; Koning, A H J; van Deurzen, C H M; Jager, A; van Lankeren, W; Koppert, L B

    2018-07-01

    Accurate measurement of tumour response during and after neoadjuvant chemotherapy (NAC) is important and may influence treatment decisions in invasive breast cancer patients. Breast MRI forms the gold standard but is more burdensome, time consuming and costly. In this study response measurement was done with 3-D ultrasound by Automated Breast Volume Scanner (ABVS) and compared to breast MRI. Moreover, patient satisfaction with both techniques was compared. A single-institution, prospective observational pilot study evaluating tumour response by ABVS in addition to breast MRI (standard care) was performed in 25 invasive breast cancer patients receiving NAC. Tumour response was evaluated comparing longest tumour diameters as well as tumour volumes at predefined time points using Bland-Altman analysis. Volume measurements for breast MRI were obtained using a fully immersive virtual reality system (a Barco I-Space) and V-Scope software. Same software was used to obtain ABVS volume measurements using an in-house developed desktop VR system. Inter- and intra-observer agreement was evaluated by Intraclass Correlation Coefficient (ICC). Twenty-five patients were eligible for baseline measurement, 20 for a mid-NAC response evaluation, and five for a post-NAC response evaluation. MRI and ABVS showed absolute concordance in 73% of patients for the mid-NAC evaluation, with a 'good' correlation for the difference in longest diameter measurement (ICC 0.73, p < 0.01) as compared to baseline assessment. Concerning difference in volume measurement in the mid-NAC response evaluation showed a 'fair' correlation (ICC 0.52, p < 0.01) and in the post-NAC response evaluation an 'excellent' correlation (ICC 0.98, p < 0.01). 'Excellent' inter- and intra-observer agreement was found (ICC 0.88, p < 0.01) with comparable limits of agreement (LOA) for observer 1 and 2 in both diameter and volume measurement. Patient satisfaction was higher for ABVS compared to breast MRI, 93% versus 12% respectively. ABVS showed 'good' correlation with MRI tumour response evaluation in breast cancer patients during NAC with 'excellent' inter- and intra-observer agreement. ABVS has patients' preference over breast MRI and could be considered as alternative to breast MRI, in case results on an on-going prospective trial confirm these results (NTR6799). Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Cross-cultural adaptation and validation of the Japanese version of the new Knee Society Scoring System for osteoarthritic knee with total knee arthroplasty.

    PubMed

    Hamamoto, Yosuke; Ito, Hiromu; Furu, Moritoshi; Ishikawa, Masahiro; Azukizawa, Masayuki; Kuriyama, Shinichi; Nakamura, Shinichiro; Matsuda, Shuichi

    2015-09-01

    The purposes of this study were to translate the new Knee Society Score (KSS) into Japanese and to evaluate the construct and content validity, test-retest reliability, and internal consistency of the Japanese version of the new KSS. The Japanese version of the KSS was developed according to cross-cultural guidelines by using the "translation-back translation" method to ensure content validity. KSS data were then obtained from patients who had undergone total knee arthroplasty (TKA). The psychometric properties evaluated were as follows: for feasibility, response rate, and floor and ceiling effects; for construct validity, internal consistency using Cronbach's alpha, and correlations with quality of life. Construct validity was evaluated by using Spearman's correlation coefficient to quantify the correlation between the KSS and the Japanese version of the Oxford 12-item Knee Score or Short Form 36 Health Survey (SF-36) questionnaires. The Japanese version of the KSS was sent to 93 consecutive osteoarthritic patients who underwent primary TKA in our institution. Fifty-five patients completed the questionnaires and were included in this study. Neither a floor nor ceiling effect was observed. The reliability proved excellent in the majority of domains, with intraclass correlation coefficients of 0.65-0.88. Internal consistency, assessed by Cronbach's alpha, was good to excellent for all domains (0.78-0.94). All of the four domains of the KSS correlated significantly with the Oxford 12-item Knee Score. The activity and satisfaction domains of the KSS correlated significantly with all and the majority of subscales of the SF-36, respectively, whereas symptoms and expectation domains showed significant correlations only with bodily pain and vitality subscales and with the physical function, bodily pain, and vitality subscales, respectively. The Japanese version of the new KSS is a valid, reliable, and responsive instrument to capture subjective aspects of the functional symptoms and abilities of patients who undergo TKA.

  5. Demonstrations of Wave Optics (Interference and Diffraction of Light) for Large Audiences Using a Laser and a Multimedia Projector

    ERIC Educational Resources Information Center

    Ivanov, Dragia; Nikolov, Stefan

    2011-01-01

    This article presents a new technique for performing most well-known demonstrations of wave optics. Demonstrations which are normally very hard to show to more than a few people can be presented easily to very large audiences with excellent visibility for everyone. The proposed setup is easy to put together and use and can be very useful for…

  6. Stretchable Platinum Network-Based Transparent Electrodes for Highly Sensitive Wearable Electronics.

    PubMed

    Wang, Yuting; Cheng, Jing; Xing, Yan; Shahid, Muhammad; Nishijima, Hiroki; Pan, Wei

    2017-07-01

    A platinum network-based transparent electrode has been fabricated by electrospinning. The unique nanobelt structured electrode demonstrates low sheet resistance (about 16 Ω sq -1 ) and high transparency of 80% and excellent flexibility. One of the most interesting demonstrations of this Pt nanobelt electrode is its excellent reversibly resilient characteristic. The electric conductivity of the flexible Pt electrode can recover to its initial value after 160% extending and this performance is repeatable and stable. The good linear relationship between the resistance and strain of the unique structured Pt electrode makes it possible to assemble a wearable high sensitive strain sensor. Present reported Pt nanobelt electrode also reveals potential applications in electrode for flexible fuel cells and highly transparent ultraviolet (UV) sensors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Functional Status Score for the Intensive Care Unit (FSS-ICU): An International Clinimetric Analysis of Validity, Responsiveness, and Minimal Important Difference

    PubMed Central

    Huang, Minxuan; Chan, Kitty S.; Zanni, Jennifer M.; Parry, Selina M.; Neto, Saint-Clair G. B.; Neto, Jose A. A.; da Silva, Vinicius Z. M.; Kho, Michelle E.; Needham, Dale M.

    2017-01-01

    Objective To evaluate the internal consistency, validity, responsiveness, and minimal important difference of the Functional Status Score for the Intensive Care Unit (FSS-ICU), a physical function measure designed for the intensive care unit (ICU). Design Clinimetric analysis. Settings Five international data sets from the United States, Australia, and Brazil. Patients 819 ICU patients. Intervention None. Measurements and Main Results Clinimetric analyses were initially conducted separately for each data source and time point to examine generalizability of findings, with pooled analyses performed thereafter to increase power of analyses. The FSS-ICU demonstrated good to excellent internal consistency. There was good convergent and discriminant validity, with significant and positive correlations (r = 0.30 to 0.95) between FSS-ICU and other physical function measures, and generally weaker correlations with non-physical measures (|r| = 0.01 to 0.70). Known group validity was demonstrated by significantly higher FSS-ICU scores among patients without ICU-acquired weakness (Medical Research Council sumscore ≥48 versus <48) and with hospital discharge to home (versus healthcare facility). FSS-ICU at ICU discharge predicted post-ICU hospital length of stay and discharge location. Responsiveness was supported via increased FSS-ICU scores with improvements in muscle strength. Distribution-based methods indicated a minimal important difference of 2.0 to 5.0. Conclusions The FSS-ICU has good internal consistency and is a valid and responsive measure of physical function for ICU patients. The estimated minimal important difference can be used in sample size calculations and in interpreting studies comparing the physical function of groups of ICU patients. PMID:27488220

  8. Comparison of SF-36 vitality scale and Fatigue Symptom Inventory in assessing cancer-related fatigue.

    PubMed

    Brown, Linda F; Kroenke, Kurt; Theobald, Dale E; Wu, Jingwei

    2011-08-01

    Cancer-related fatigue (CRF) is an important symptom in clinical practice and research. The best way to measure it, however, remains unsettled. The SF-36 vitality scale, a general measure of energy/fatigue, is a frequently cited measure. With only four items, however, its ability to adequately represent multiple CRF facets has been questioned. The 13-item Fatigue Symptom Inventory (FSI) was developed to assess multidimensional aspects of CRF. Our objectives were to assess the convergent validity and to compare the sensitivity to change of the two scales. We administered both scales at 1 month (n = 68) and 6 months (n = 96) to a subset of heterogeneous patients receiving treatment in 16 cancer centers who were enrolled in a clinical trial of pain and depression. Distributions of standardized response means (SRMs) were compared to assess sensitivity to change. Results of both scales were compared to scores on a single fatigue item from the Patient Health Questionnaire (PHQ). Mean scores for both the FSI and the vitality scale demonstrated clinically significant fatigue in the sample. The vitality scale was strongly correlated with all three FSI scales (r = -0.68 to -0.77). The vitality and FSI scales also correlated strongly with the PHQ fatigue item. Moreover, distributions of SRMs for both scales were approximately normal. Both the FSI and the vitality scale are supported as valid measures of CRF. Both demonstrated sensitivity to change across a range of effect sizes. The vitality scale may be an excellent choice when brevity is paramount; the FSI may be more appropriate when tapping specific dimensions is warranted.

  9. Analytical nuclear gradients for the range-separated many-body dispersion model of noncovalent interactions.

    PubMed

    Blood-Forsythe, Martin A; Markovich, Thomas; DiStasio, Robert A; Car, Roberto; Aspuru-Guzik, Alán

    2016-03-01

    An accurate treatment of the long-range electron correlation energy, including van der Waals (vdW) or dispersion interactions, is essential for describing the structure, dynamics, and function of a wide variety of systems. Among the most accurate models for including dispersion into density functional theory (DFT) is the range-separated many-body dispersion (MBD) method [A. Ambrosetti et al. , J. Chem. Phys. , 2014, 140 , 18A508], in which the correlation energy is modeled at short-range by a semi-local density functional and at long-range by a model system of coupled quantum harmonic oscillators. In this work, we develop analytical gradients of the MBD energy with respect to nuclear coordinates, including all implicit coordinate dependencies arising from the partitioning of the charge density into Hirshfeld effective volumes. To demonstrate the efficiency and accuracy of these MBD gradients for geometry optimizations of systems with intermolecular and intramolecular interactions, we optimized conformers of the benzene dimer and isolated small peptides with aromatic side-chains. We find excellent agreement with the wavefunction theory reference geometries of these systems (at a fraction of the computational cost) and find that MBD consistently outperforms the popular TS and D3(BJ) dispersion corrections. To demonstrate the performance of the MBD model on a larger system with supramolecular interactions, we optimized the C 60 @C 60 H 28 buckyball catcher host-guest complex. In our analysis, we also find that neglecting the implicit nuclear coordinate dependence arising from the charge density partitioning, as has been done in prior numerical treatments, leads to an unacceptable error in the MBD forces, with relative errors of ∼20% (on average) that can extend well beyond 100%.

  10. Demonstration of the test-retest reliability and sensitivity of the Lower Limb Functional Index-10 as a measure of functional recovery post burn injury: a cross-sectional repeated measures study design.

    PubMed

    Ryland, Margaret E; Grisbrook, Tiffany L; Wood, Fiona M; Phillips, Michael; Edgar, Dale W

    2016-01-01

    Lower limb burns can significantly delay recovery of function. Measuring lower limb functional outcomes is challenging in the unique burn patient population and necessitates the use of reliable and valid tools. The aims of this study were to examine the test-retest reliability, sensitivity, and internal consistency of Sections 1 and 3 of the Lower Limb Functional Index-10 (LLFI-10) questionnaire for measuring functional ability in patients with lower limb burns over time. Twenty-nine adult patients who had sustained a lower limb burn injury in the previous 12 months completed the test-retest procedure of the study. In addition, the minimal detectable change (MDC) was calculated for Section 1 and 3 of the LLFI-10. Section 1 is focused on the activity limitations experienced by patients with a lower limb disorder whereas Section 3 involves patients indicating their current percentage of pre-injury duties. Section 1 of the LLFI-10 demonstrated excellent test-retest reliability (intra-class correlation coefficient (ICC) 0.98, 95 % CI 0.96-0.99) whilst Section 3 demonstrated high test-retest reliability (ICC 0.88, 95 % CI 0.79-0.94). MDC scores for Sections 1 and 3 were 1.27 points and 30.22 %, respectively. Internal consistency was demonstrated with a significant negative association (r s  = -0.83) between Sections 1 and 3 of the LLFI-10 (p < 0.001). This study demonstrates that Section 1 and 3 of the LLFI-10 are reliable for measuring functional ability in patients who have sustained lower limb burns in the previous 12 months, and furthermore, Section 1 is sensitive to changes in patient function over time.

  11. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    PubMed Central

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A

    2018-01-01

    Purpose The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. Conclusion The TIRE measures of MIP, SMIP and ID have excellent test–retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP. PMID:29805255

  12. Nanodiamond-Based Composite Structures for Biomedical Imaging and Drug Delivery.

    PubMed

    Rosenholm, Jessica M; Vlasov, Igor I; Burikov, Sergey A; Dolenko, Tatiana A; Shenderova, Olga A

    2015-02-01

    Nanodiamond particles are widely recognized candidates for biomedical applications due to their excellent biocompatibility, bright photoluminescence based on color centers and outstanding photostability. Recently, more complex architectures with a nanodiamond core and an external shell or nanostructure which provides synergistic benefits have been developed, and their feasibility for biomedical applications has been demonstrated. This review is aimed at summarizing recent achievements in the fabrication and functional demonstrations of nanodiamond-based composite structures, along with critical considerations that should be taken into account in the design of such structures from a biomedical point of view. A particular focus of the review is core/shell structures of nanodiamond surrounded by porous silica shells, which demonstrate a remarkable increase in drug loading efficiency; as well as nanodiamonds decorated with carbon dots, which have excellent potential as bioimaging probes. Other combinations are also considered, relying on the discussed inherent properties of the inorganic materials being integrated in a way to advance inorganic nanomedicine in the quest for better health-related nanotechnology.

  13. Cumulative Retrospective Exposure Assessment (REA) as a predictor of amphibole asbestos lung burden: validation procedures and results for industrial hygiene and pathology estimates.

    PubMed

    Rasmuson, James O; Roggli, Victor L; Boelter, Fred W; Rasmuson, Eric J; Redinger, Charles F

    2014-01-01

    A detailed evaluation of the correlation and linearity of industrial hygiene retrospective exposure assessment (REA) for cumulative asbestos exposure with asbestos lung burden analysis (LBA) has not been previously performed, but both methods are utilized for case-control and cohort studies and other applications such as setting occupational exposure limits. (a) To correlate REA with asbestos LBA for a large number of cases from varied industries and exposure scenarios; (b) to evaluate the linearity, precision, and applicability of both industrial hygiene exposure reconstruction and LBA; and (c) to demonstrate validation methods for REA. A panel of four experienced industrial hygiene raters independently estimated the cumulative asbestos exposure for 363 cases with limited exposure details in which asbestos LBA had been independently determined. LBA for asbestos bodies was performed by a pathologist by both light microscopy and scanning electron microscopy (SEM) and free asbestos fibers by SEM. Precision, reliability, correlation and linearity were evaluated via intraclass correlation, regression analysis and analysis of covariance. Plaintiff's answers to interrogatories, work history sheets, work summaries or plaintiff's discovery depositions that were obtained in court cases involving asbestos were utilized by the pathologist to provide a summarized brief asbestos exposure and work history for each of the 363 cases. Linear relationships between REA and LBA were found when adjustment was made for asbestos fiber-type exposure differences. Significant correlation between REA and LBA was found with amphibole asbestos lung burden and mixed fiber-types, but not with chrysotile. The intraclass correlation coefficients (ICC) for the precision of the industrial hygiene rater cumulative asbestos exposure estimates and the precision of repeated laboratory analysis were found to be in the excellent range. The ICC estimates were performed independent of specific asbestos fiber-type. Both REA and pathology assessment are reliable and complementary predictive methods to characterize asbestos exposures. Correlation analysis between the two methods effectively validates both REA methodology and LBA procedures within the determined precision, particularly for cumulative amphibole asbestos exposures since chrysotile fibers, for the most part, are not retained in the lung for an extended period of time.

  14. Selection for Surgical Training: An Evidence-Based Review.

    PubMed

    Schaverien, Mark V

    2016-01-01

    The predictive relationship between candidate selection criteria for surgical training programs and future performance during and at the completion of training has been investigated for several surgical specialties, however there is no interspecialty agreement regarding which selection criteria should be used. Better understanding the predictive reliability between factors at selection and future performance may help to optimize the process and lead to greater standardization of the surgical selection process. PubMed and Ovid MEDLINE databases were searched. Over 560 potentially relevant publications were identified using the search strategy and screened using the Cochrane Collaboration Data Extraction and Assessment Template. 57 studies met the inclusion criteria. Several selection criteria used in the traditional selection demonstrated inconsistent correlation with subsequent performance during and at the end of surgical training. The following selection criteria, however, demonstrated good predictive relationships with subsequent resident performance: USMLE examination scores, Letters of Recommendation (LOR) including the Medical Student Performance Evaluation (MSPE), academic performance during clinical clerkships, the interview process, displaying excellence in extracurricular activities, and the use of unadjusted rank lists. This systematic review supports that the current selection process needs to be further evaluated and improved. Multicenter studies using standardized outcome measures of success are now required to improve the reliability of the selection process to select the best trainees. Published by Elsevier Inc.

  15. The Psychometric Properties of an Arabic version of the PedsQL Multidimensional Fatigue Scale Tested for Children with Cancer.

    PubMed

    Al-Gamal, Ekhlas; Long, Tony

    2017-09-01

    Fatigue is considered to be one of the most reported symptoms experienced by children with cancer. A major aim of this study was to develop an Arabic version of the Pediatric Quality of Life (PedsQL) Multidimensional Fatigue Scale (child report) and to test its psychometric proprieties for the assessment of fatigue in Arabic children with cancer. The PedsQL Multidimensional Fatigue Scale (Arabic version) and the PedsQL TM 4.0 Generic Core scale (existing Arabic version) were completed by 70 Jordanian children with cancer. Cronbach's alpha coefficients were found to be 0.90 for the total PedsQL Multidimensional Fatigue Scale (Arabic version), 0.94 for the general fatigue subscale, 0.67 for the sleep/rest fatigue subscale, and 0.87 for the cognitive fatigue subscale. The PedsQL Multidimensional Fatigue Scale scores correlated significantly with the PedsQL TM 4.0 Generic Core scale and demonstrated good construct validity. The results demonstrate excellent reliability and good validity of the PedsQL Multidimensional Fatigue Scale (Arabic version) for children with cancer. This is the first validated scale that assesses fatigue in Arabic children with cancer. The English scale has been used with several pediatric clinical populations, so this Arabic version may be equally useful beyond the field of cancer.

  16. Pre-clinical development of a hydrogen peroxide-inactivated West Nile virus vaccine.

    PubMed

    Poore, Elizabeth A; Slifka, Dawn K; Raué, Hans-Peter; Thomas, Archana; Hammarlund, Erika; Quintel, Benjamin K; Torrey, Lindsay L; Slifka, Ariel M; Richner, Justin M; Dubois, Melissa E; Johnson, Lawrence P; Diamond, Michael S; Slifka, Mark K; Amanna, Ian J

    2017-01-05

    West Nile virus (WNV) is a mosquito-transmitted pathogen with a wide geographical range that can lead to long-term disability and death in some cases. Despite the public health risk posed by WNV, including an estimated 3 million infections in the United States alone, no vaccine is available for use in humans. Here, we present a scaled manufacturing approach for production of a hydrogen peroxide-inactivated whole virion WNV vaccine, termed HydroVax-001WNV. Vaccination resulted in robust virus-specific neutralizing antibody responses and protection against WNV-associated mortality in mice or viremia in rhesus macaques (RM). A GLP-compliant toxicology study performed in rats demonstrated an excellent safety profile with clinical findings limited to minor and transient irritation at the injection site. An in vitro relative potency (IVRP) assay was developed and shown to correlate with in vivo responses following forced degradation studies. Long-term in vivo potency comparisons between the intended storage condition (2-8°C) and a thermally stressed condition (40±2°C) demonstrated no loss in vaccine efficacy or protective immunity over a 6-month span of time. Together, the positive pre-clinical findings regarding immunogenicity, safety, and stability indicate that HydroVax-001WNV is a promising vaccine candidate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Tracking Diurnal Variation in Photosynthetic Down-Regulation Using Low Cost Spectroscopic Instrumentation

    PubMed Central

    van Leeuwen, Martin; Kremens, Robert L.; van Aardt, Jan

    2015-01-01

    Photosynthetic light-use efficiency (LUE) has gained wide interest as an input to modeling forest gross primary productivity (GPP). The photochemical reflectance index (PRI) has been identified as a principle means to inform LUE-based models, using airborne and satellite-based observations of canopy reflectance. More recently, low-cost electronics have become available with the potential to provide for dense in situ time-series measurements of PRI. A recent design makes use of interference filters to record light transmission within narrow wavebands. Uncertainty remains as to the dynamic range of these sensors and performance under low light conditions, the placement of the reference band, and methodology for reflectance calibration. This paper presents a low-cost sensor design and is tested in a laboratory set-up, as well in the field. The results demonstrate an excellent performance against a calibration standard (R2 = 0.9999) and at low light conditions. Radiance measurements over vegetation demonstrate a reversible reduction in green reflectance that was, however, seen in both the reference and signal wavebands. Time-series field measurements of PRI in a Douglas-fir canopy showed a weak correlation with eddy-covariance-derived LUE and a significant decline in PRI over the season. Effects of light quality, bidirectional scattering effects, and possible sensor artifacts on PRI are discussed. PMID:25951342

  18. Cationic Copolymerization of 3,3-Bis(hydroxymethyl)oxetane and Glycidol: Biocompatible Hyperbranched Polyether Polyols with High Content of Primary Hydroxyl Groups.

    PubMed

    Christ, Eva-Maria; Hobernik, Dominika; Bros, Matthias; Wagner, Manfred; Frey, Holger

    2015-10-12

    The cationic ring-opening copolymerization of 3,3-bis(hydroxymethyl)oxetane (BHMO) with glycidol using different comonomer ratios (BHMO content from 25 to 90%) and BF3OEt2 as an initiator has been studied. Apparent molecular weights of the resulting hyperbranched polyether copolymers ranged from 1400 to 3300 g mol(-1) (PDI: 1.21-1.48; method: SEC, linear PEG standards). Incorporation of both comonomers is evidenced by MALDI-TOF mass spectroscopy. All hyperbranched polyether polyols with high content of primary hydroxyl groups portray good solubility in water, which correlates with an increasing content of glycerol units. Detailed NMR characterization was employed to elucidate the copolymer microstructures. Kinetic studies via FTIR demonstrated a weak gradient-type character of the copolymers. MTT assays of the copolymers (up to 100 μg mL(-1)) on HEK and fibroblast cell lines (3T3, L929, WEHI) as well as viability tests on the fibroblast cells were carried out to assess the biocompatibility of the materials, confirming excellent biocompatibility. Transfection efficiency characterization by flow cytometry and confocal laser microscopy demonstrated cellular uptake of the copolymers. Antiadhesive properties of the materials on surfaces were assessed by adhesion assays with fibroblast cells.

  19. Cross-cultural adaptation into Punjabi of the English version of the Hospital Anxiety and Depression Scale.

    PubMed

    Lane, Deirdre A; Jajoo, Jagdish; Taylor, Rod S; Lip, Gregory Yh; Jolly, Kate

    2007-01-26

    We wanted to use a Punjabi version of the Hospital Anxiety and Depression Scale (HADS) to enable non-English speaking patients to participate in a clinical trial. The aim of the study was to translate and validate the Hospital Anxiety and Depression Scale into Punjabi. The HADS was translated into Punjabi by a multidisciplinary team, verified against the original version, and administered to 73 bilingual patients attending an outpatient clinic. One sample t-tests and the Bland-Altman plots demonstrated acceptable linguistic agreement between the two versions of the HADS. Spearman's rank-order correlation coefficients (p < 0.0001) demonstrate excellent conceptual agreement between each item and its corresponding subscale score, for both versions. Concordance rates revealed that the Punjabi HADS adequately identified borderline cases of anxiety (80.8%), definite cases of anxiety (91.8%) and depression (91.8%), but was less reliable in identifying borderline cases of depression (65.8%). Cronbach alpha coefficients revealed high levels of internal consistency for both the Punjabi and English versions (0.81 and 0.86 for anxiety and 0.71 and 0.85 for depression, respectively). The Punjabi HADS is an acceptable, reliable and valid measure of anxiety and depression among physically ill Punjabi speaking people in the United Kingdom.

  20. Thermoelectric efficiency of (1 - x)(GeTe) x(Bi2Se0.2Te2.8) and implementation into highly performing thermoelectric power generators.

    PubMed

    Koenig, J; Winkler, M; Dankwort, T; Hansen, A-L; Pernau, H-F; Duppel, V; Jaegle, M; Bartholomé, K; Kienle, L; Bensch, W

    2015-02-14

    Here we report for the first time on a complete simulation assisted "material to module" development of a high performance thermoelectric generator (TEG) based on the combination of a phase change material and established thermoelectrics yielding the compositions (1 - x)(GeTe) x(Bi(2)Se(0.2)Te(2.8)). For the generator design our approach for benchmarking thermoelectric materials is demonstrated which is not restricted to the determination of the intrinsically imprecise ZT value but includes the implementation of the material into a TEG. This approach is enabling a much more reliable benchmarking of thermoelectric materials for TEG application. Furthermore we analyzed the microstructure and performance close to in-operandi conditions for two different compositions in order to demonstrate the sensitivity of the material against processing and thermal cycling. For x = 0.038 the microstructure of the as-prepared material remains unchanged, consequently, excellent and stable thermoelectric performance as prerequisites for TEG production was obtained. For x = 0.063 we observed strain phenomena for the pristine state which are released by the formation of planar defects after thermal cycling. Consequently the thermoelectric performance degrades significantly. These findings highlight a complication for deriving the correlation of microstructure and properties of thermoelectric materials in general.