Sample records for dental implants

  1. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    PubMed

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  2. A review of nanostructured surfaces and materials for dental implants: surface coating, patterning and functionalization for improved performance.

    PubMed

    Rasouli, Rahimeh; Barhoum, Ahmed; Uludag, Hasan

    2018-05-10

    The emerging field of nanostructured implants has enormous scope in the areas of medical science and dental implants. Surface nanofeatures provide significant potential solutions to medical problems by the introduction of better biomaterials, improved implant design, and surface engineering techniques such as coating, patterning, functionalization and molecular grafting at the nanoscale. This review is of an interdisciplinary nature, addressing the history and development of dental implants and the emerging area of nanotechnology in dental implants. After a brief introduction to nanotechnology in dental implants and the main classes of dental implants, an overview of different types of nanomaterials (i.e. metals, metal oxides, ceramics, polymers and hydrides) used in dental implant together with their unique properties, the influence of elemental compositions, and surface morphologies and possible applications are presented from a chemical point of view. In the core of this review, the dental implant materials, physical and chemical fabrication techniques and the role of nanotechnology in achieving ideal dental implants have been discussed. Finally, the critical parameters in dental implant design and available data on the current dental implant surfaces that use nanotopography in clinical dentistry have been discussed.

  3. R&D on dental implants breakage

    NASA Astrophysics Data System (ADS)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  4. Clinical and radiological investigations of mandibular overdentures supported by conventional or mini-dental implants: A 2-year prospective follow-up study.

    PubMed

    Temizel, Sonay; Heinemann, Friedhelm; Dirk, Cornelius; Bourauel, Christoph; Hasan, Istabrak

    2017-02-01

    Conventional dental implants are not applicable in the mandibular interforaminal region if bone volume is limited. Mini-dental implants offer an alternative means of supporting mandibular overdentures in a narrow residual ridge, without additional surgery. The purpose of this nonrandomized clinical trial was to compare the ability of mini-dental implants with that of conventional dental implants in supporting mandibular overdentures during a 2-year clinical follow-up. Bone quality, bone resorption, implant stability, and oral health were assessed radiographically. A total of 32 participants with edentulism were included. Twenty-two participants (99 implants) received 4 to 5 mini-dental implants (diameter: 1.8-2.4 mm; length: 13-15 mm, study group), and 10 participants (35 implants) received 2 to 4 conventional dental implants (diameter: 3.3-3.7 mm; length: 11-13 mm, control group). The selection of the participants in the study or control group was based on the available bone volume in the mandible. The selection was not randomized. The density of cortical bone thickness was measured in Hounsfield units (HU) from computed tomography data, and patients were followed for 2 years. The participants were examined 3, 6, 12, and 24 months after surgery. Primary stability immediately after the insertion of dental implants (Periotest), secondary stability 6 months after implantation, modified plaque, bleeding on probing indices, and probing depth were measured and analyzed statistically (α=.05). The mean HU value 6 months after implantation in the participants who received mini-dental implants was significantly (P=.035) higher (1250 HU) than that in the participants who received conventional dental implants (1100 HU). The probing depths around the conventional dental implants (1.6 and 1.8 mm, respectively) were significantly higher than those around the mini-dental implants (1.3 and 1.2 mm, respectively) 12 and 24 months after surgery, respectively (P<.001). The mean primary and secondary stability values for conventional dental implants were -4.0 and -4.9, respectively. The primary and secondary stability values for the mini-dental implants were -0.3 and -1.4, respectively. The Periotest values of the primary (measured immediately after implant insertion) and secondary implant stabilities (measured 6 months after implant insertion) were significantly higher for the conventional dental implants than for the mini-dental implants (P<.001). Based on this 2-year clinical trial, patients receiving mini-dental implants had clinical outcomes similar to those of patients receiving conventional dental implants to support overdenture prostheses. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial.

    PubMed

    Aunmeungtong, Weerapan; Kumchai, Thongnard; Strietzel, Frank P; Reichart, Peter A; Khongkhunthian, Pathawee

    2017-04-01

    Dental implant-retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental implants, and components for retaining overdentures, are commercially available. However, comparative clinical studies comparing mini dental implants and conventional dental implants using different attachment for implant-retained overdentures have not been well documented. To compare the clinical outcomes of using two mini dental implants with Equator ® attachments, four mini dental implants with Equator attachments, or two conventional dental implants with ball attachments, by means of a randomized clinical trial. Sixty patients received implant-retained mandibular overdentures in the interforaminal region. The patients were divided into three groups. In Groups 1 and 2, two and four mini dental implants, respectively, were placed and immediately loaded by overdentures, using Equator ® attachments. In Group 3, conventional implants were placed. After osseointegration, the implants were loaded by overdentures, using ball attachments. The study distribution was randomized and double-blinded. Outcome measures included changes in radiological peri-implant bone level from surgery to 12 months postinsertion, prosthodontic complications and patient satisfaction. The cumulative survival rate in the three clinical groups after one year was 100%. There was no significant difference (p < 0.05) in clinical results regarding the number (two or four) of mini dental implants with Equator attachments. However, there was a significant difference in marginal bone loss and patient satisfaction between those receiving mini dental implants with Equator attachments and conventional dental implants with ball attachments. The marginal bone resorption in Group 3 was significantly higher than in Groups 1 and 2 (p < 0.05); there were no significant differences between Groups 1 and 2. There was no significant difference in patient satisfaction between Groups 1 and 2 but it was significantly higher than that in Group3 (p < 0.05). Two and four mini dental implants can be immediately used successfully for retaining lower complete dentures, as shown after a 1-year follow up. © 2016 Wiley Periodicals, Inc.

  6. 78 FR 2647 - Dental Devices; Reclassification of Blade-Form Endosseous Dental Implant

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-14

    .... FDA-2012-N-0677] Dental Devices; Reclassification of Blade-Form Endosseous Dental Implant AGENCY: Food...) is proposing to reclassify the blade- form endosseous dental implant, a preamendments class III... proposing to revise the classification of blade-form endosseous dental implants. DATES: Submit either...

  7. Correlation between radiographic analysis of alveolar bone density around dental implant and resonance frequency of dental implant

    NASA Astrophysics Data System (ADS)

    Prawoko, S. S.; Nelwan, L. C.; Odang, R. W.; Kusdhany, L. S.

    2017-08-01

    The histomorphometric test is the gold standard for dental implant stability quantification; however, it is invasive, and therefore, it is inapplicable to clinical patients. Consequently, accurate and objective alternative methods are required. Resonance frequency analysis (RFA) and digital radiographic analysis are noninvasive methods with excellent objectivity and reproducibility. To analyze the correlation between the radiographic analysis of alveolar bone density around a dental implant and the resonance frequency of the dental implant. Digital radiographic images for 35 samples were obtained, and the resonance frequency of the dental implant was acquired using Osstell ISQ immediately after dental implant placement and on third-month follow-up. The alveolar bone density around the dental implant was subsequently analyzed using SIDEXIS-XG software. No significant correlation was reported between the alveolar bone density around the dental implant and the resonance frequency of the dental implant (r = -0.102 at baseline, r = 0.146 at follow-up, p > 0.05). However, the alveolar bone density and resonance frequency showed a significant difference throughout the healing period (p = 0.005 and p = 0.000, respectively). Conclusion: Digital dental radiographs and Osstell ISQ showed excellent objectivity and reproducibility in quantifying dental implant stability. Nonetheless, no significant correlation was observed between the results obtained using these two methods.

  8. Dental implants in medically complex patients-a retrospective study.

    PubMed

    Manor, Yifat; Simon, Roy; Haim, Doron; Garfunkel, Adi; Moses, Ofer

    2017-03-01

    Dental implant insertion for oral rehabilitation is a worldwide procedure for healthy and medically compromised patients. The impact of systemic disease risks on the outcome of implant therapy is unclear, since there are few if any published randomized controlled trials (RCTs). The objective of this study is to investigate the rate of complications and failures following dental implantation in medically compromised patients in order to elucidate risk factors and prevent them. A retrospective cohort study was conducted from patient files treated with dental implantation between the years 2008-2014. The study group consisted of medically complex patients while the control group consisted of healthy patients. Preoperative, intraoperative, and post operative clinical details were retrieved from patients' files. The survival rate and the success rate of the dental implants were evaluated clinically and radiographically. A total of 204 patients (1003 dental implants) were included in the research, in the study group, 93 patients with 528 dental implants and in the control group, 111 patients with 475 dental implants. No significant differences were found between the groups regarding implant failures or complications. The failure rate of dental implants among the patients was 11.8 % in the study group and 16.2 % in the control group (P = 0.04). It was found that patients with a higher number of implants (mean 6.8) had failures compared with patients with a lower number of implants (mean 4.2) regardless of their health status (P < 0.01). We found a similar rate of failure and complications of dental implantation in medically complex patients and in healthy patients. Medically complex patients can undergo dental implantation. There are similar rates of complications and failures of dental implants in medically complex patients and in healthy patients.

  9. Assessment of Various Risk Factors for Success of Delayed and Immediate Loaded Dental Implants: A Retrospective Analysis.

    PubMed

    Prasant, M C; Thukral, Rishi; Kumar, Sachin; Sadrani, Sannishth M; Baxi, Harsh; Shah, Aditi

    2016-10-01

    Ever since its introduction in 1977, a minimum of few months of period is required for osseointegration to take place after dental implant surgery. With the passage of time and advancements in the fields of dental implant, this healing period is getting smaller and smaller. Immediate loading of dental implants is becoming a very popular procedure in the recent time. Hence, we retrospectively analyzed the various risk factors for the failure of delayed and immediate loaded dental implants. In the present study, retrospective analysis of all the patients was done who underwent dental implant surgeries either by immediate loading procedure or by delayed loading procedures. All the patients were divided broadly into two groups with one group containing patients in which delayed loaded dental implants were placed while other consisted of patients in whom immediate loaded dental implants were placed. All the patients in whom follow-up records were missing and who had past medical history of any systemic diseases were excluded from the present study. Evaluation of associated possible risk factors was done by classifying the predictable factors as primary and secondary factors. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. Kaplan-Meier survival analyses and chi-square test were used for assessment of level of significance. In delayed and immediate group of dental implants, mean age of the patients was 54.2 and 54.8 years respectively. Statistically significant results were obtained while comparing the clinical parameters of the dental implants in both the groups while demographic parameters showed nonsignificant correlation. Significant higher risk of dental implant failure is associated with immediate loaded dental implants. Tobacco smoking, shorter implant size, and other risk factors play a significant role in predicting the success and failure of dental implants. Delayed loaded dental implant placement should be preferred as they are associated with decreased risk of implant failure.

  10. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  11. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  12. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  13. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  14. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  15. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

    PubMed

    Aunmeungtong, W; Khongkhunthian, P; Rungsiyakull, P

    2016-01-01

    Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.

  16. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  17. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  18. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  19. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  20. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  1. 21 CFR 872.3640 - Endosseous dental implant.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  2. 21 CFR 872.3640 - Endosseous dental implant.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  3. 21 CFR 872.3640 - Endosseous dental implant.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  4. 21 CFR 872.3640 - Endosseous dental implant.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  5. 21 CFR 872.3640 - Endosseous dental implant.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  6. Public perceptions of dental implants: a qualitative study.

    PubMed

    Wang, Guihua; Gao, Xiaoli; Lo, Edward C M

    2015-07-01

    Dental implants have become a popular option for treating partially dentate or edentulous patients. Information on dental implants is widely available in the public domain and is disseminated through industries and dental practitioners at various levels/disciplines. This qualitative study aimed to evaluate the public's information acquisition and their perceptions of dental implants and the effects of these on their care-seeking and decision making. A purposive sample of 28 adults were recruited to join six focus groups. To be eligible, one must be 35-64 years of age, had never been engaged in dentally related jobs, had at least one missing tooth, and had heard about dental implant but never received dental implant or entered into any dental consultation regarding dental implants. All of the focus groups discussions were transcribed verbatim and subjected to thematic content analysis following a grounded theory approach. Participants acquired information on dental implants through various means, such as patient information boards, printed advertisements, social media, and personal connections. They expected dental implants to restore the patients' appearance, functions, and quality of life to absolute normality. They regarded dental implants as a panacea for all cases of missing teeth, overestimated their functions and longevity, and underestimated the expertise needed to carry out the clinical procedures. They were deterred from seeking dental implant treatment by the high price, invasive procedures, risks, and complications. Members of the public were exposed to information of varying quality and had some unrealistic expectations regarding dental implants. Such perceptions may shape their care-seeking behaviours and decision-making processes in one way or another. The views and experiences gathered in this qualitative study could assist clinicians to better understand the public's perspectives, facilitate constructive patient-dentist communication, and contribute to the creation of positive clinical experiences in implant dentistry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Current trends in dental implants

    PubMed Central

    Gaviria, Laura; Salcido, John Paul; Guda, Teja

    2014-01-01

    Tooth loss is very a very common problem; therefore, the use of dental implants is also a common practice. Although research on dental implant designs, materials and techniques has increased in the past few years and is expected to expand in the future, there is still a lot of work involved in the use of better biomaterials, implant design, surface modification and functionalization of surfaces to improve the long-term outcomes of the treatment. This paper provides a brief history and evolution of dental implants. It also describes the types of implants that have been developed, and the parameters that are presently used in the design of dental implants. Finally, it describes the trends that are employed to improve dental implant surfaces, and current technologies used for the analysis and design of the implants. PMID:24868501

  8. Knowledge and attitudes of dental interns in Karnataka state, India, regarding implants.

    PubMed

    Chaudhary, Sohini; Gowda, Triveni M; Kumar, Tarun A B; Mehta, Dhoom S

    2013-10-01

    Implant treatment today is highly reliable as a valid restorative option for missing teeth. As more patients worldwide opt for implant treatment, it is now imperative for dental practitioners to have sound information about dental implants so they can help patients make informed decisions. This study sought to define the knowledge and attitudes regarding dental implants of dental interns in the state of Karnataka, India, and to evaluate the dental implant curriculum structure at the undergraduate level. A survey was conducted of dental interns (students in their fifth, clinical year of undergraduate study) in seven of the forty-five academic dental institutions in this state. The questionnaire consisted of fifteen questions that assessed the respondents' level of knowledge and source of information regarding implants. A total of 500 questionnaires were distributed, and 417 interns responded for a response rate of 83.4 percent. In the results, 73.3 percent reported they were not provided sufficient information about implants in their undergraduate curriculum, and 95.7 percent of them wanted more. Also, 63.5 percent of the respondents believed that high costs could limit the use of dental implants as a tooth replacement modality in India. This study concludes that revision in the undergraduate dental curricula at these schools is needed to better prepare students for practicing implant dentistry.

  9. Impact of a "TED-Style" presentation on potential patients' willingness to accept dental implant therapy: a one-group, pre-test post-test study.

    PubMed

    Ghanem, Henry; Afrashtehfar, Kelvin Ian; Abi-Nader, Samer; Tamimi, Faleh

    2015-12-01

    A survey was conducted to assess the impact of a TED-like educational session on participants' willingness to accept dental implant therapy. Volunteers interested in having information about dental implant therapies were recruited and asked to complete a two-part survey before and after an educational session. The initial survey elicited demographic information, self-perceived knowledge on dental implants and willingness to this kind of treatment. A "TED-style" presentation that provided information about dental implant treatments was conducted before asking the participants to complete a second set of questions assessing the impact of the session. The survey was completed by 104 individuals, 78.8% were women and the mean age was 66.5±10.8. Before the educational session, 76.0% of the participants refused dental implants mainly due to lack of knowledge. After the educational session, the rejection of dental implants decreased by almost four folds to 20.2%. This study proved that an educational intervention can significantly increase willingness to accept treatment with dental implants in a segment of the population who is interested in having information about dental implant therapy. Furthermore, educational interventions, such as TED-like talks, might be useful to increase popular awareness on dental implant therapy.

  10. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study

    PubMed Central

    AUNMEUNGTONG, W.; KHONGKHUNTHIAN, P.; RUNGSIYAKULL, P.

    2016-01-01

    SUMMARY Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Materials and methods Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. Results There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Conclusions Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Clinical implications Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force. PMID:28042449

  11. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    PubMed

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  12. Intricate Assessment and Evaluation of Effect of Bruxism on Long-term Survival and Failure of Dental Implants: A Comparative Study.

    PubMed

    Yadav, Kajal; Nagpal, Abhishek; Agarwal, S K; Kochhar, Aarti

    2016-08-01

    Dental implants are one of the common lines of treatment used for the treatment of missing tooth. Various risk factors are responsible for the failure of the dental implants and occurrence of postoperative complications. Bruxism is one such factor responsible for the failure of the dental implants. The actual relation between bruxism and dental implants is a subject of long-term controversy. Hence, we carried out this retrospective analysis to assess the complications occurring in dental implants in patients with and without bruxism. The present study included 1100 patients which were treated for rehabilitation by dental implant procedure at 21 dental offices of Ghaziabad (India) from 2004 to 2014. Analyzing the clinical records of the patients along with assessing the photographs of the patients was done for confirming the diagnosis of bruxism. Clinical re-evaluation of the patients, who came back for follow-up, was done to confirm the diagnosis of bruxism. Systemic questionnaires as used by previous workers were used to evaluate the patients about the self-conscience of the condition. Estimation of the mechanical complications was done only in those cases which occurred on the surfaces of the restoration of the dental implants. All the results were analyzed by Statistical Package for Social Sciences (SPSS) software. Student's t-test and Pearson's chi-square test were used to evaluate the level of significance. In both bruxer and non-bruxers, maximum number of dental implants was placed in anterior maxillary region. Significant difference was obtained while comparing the two groups for dimensions of the dental implants used. On comparing the total implant failed cases between bruxers and non-bruxers group, statistically significant result was obtained. Statistically significant difference was obtained while comparing the two study groups based on the health parameters, namely hypertension, diabetes, and smoking habit. Success of dental implant is significantly affected by bruxism. Special attention is required in such patients while doing treatment planning. For the long-term clinical success and survival of dental implants in patients, special emphasis should be given on the patient's deleterious oral habits, such as bruxism as in long run, they influence the stability of dental implants.

  13. The medically compromised patient: Are dental implants a feasible option?

    PubMed

    Vissink, A; Spijkervet, Fkl; Raghoebar, G M

    2018-03-01

    In healthy subjects, dental implants have evolved to be a common therapy to solve problems related to stability and retention of dentures as well as to replace failing teeth. Although dental implants are applied in medically compromised patients, it is often not well known whether this therapy is also feasible in these patients, whether the risk of implant failure and developing peri-implantitis is increased, and what specific preventive measures, if any, have to be taken when applying dental implants in these patients. Generally speaking, as was the conclusion by the leading review of Diz, Scully, and Sanz on placement of dental implants in medically compromised patients (J Dent, 41, 2013, 195), in a few disorders implant survival may be lower, and the risk of a compromised peri-implant health and its related complications be greater, but the degree of systemic disease control outweighs the nature of the disorder rather than the risk accompanying dental implant treatment. So, as dental implant treatment is accompanied by significant functional benefits and improved oral health-related quality of life, dental implant therapy is a feasible treatment in almost any medically compromised patient when the required preventive measures are taken and follow-up care is at a high level. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  14. Finite element analysis (FEA) of dental implant fixture for mechanical stability and rapid osseointegration

    NASA Astrophysics Data System (ADS)

    Tabassum, Shafia; Murtaza, Ahmar; Ali, Hasan; Uddin, Zia Mohy; Zehra, Syedah Sadaf

    2017-10-01

    For rapid osseointegration of dental implant fixtures, various surface treatments including plasma spraying, hydroxyapatite coating, acid-etching, and surface grooving are used. However undesirable effects such as chemical modifications, loss of mechanical properties, prolonged processing times and post production treatment steps are often associated with these techniques. The osseointegration rate of the dental implants can be promoted by increasing the surface area of the dental implant, thus increasing the bone cells - implant material contact and allow bone tissues to grow rapidly. Additive Manufacturing (AM) techniques can be used to fabricate dental implant fixtures with desirable surface area in a single step manufacturing process. AM allows the use of Computer Aided Designing (CAD) for customised rapid prototyping of components with precise control over geometry. In this study, the dental implant fixture that replaces the tooth root was designed on commercially available software COMSOL. Nickel - titanium alloy was selected as build materials for dental implant. The geometry of the dental fixture was varied by changing the interspacing distance (thread pitch) and number of threads to increase the total surface area. Three different microstructures were introduced on the surface of dental implant. The designed models were used to examine the effect of changing geometries on the total surface area. Finite Element Analysis (FEA) was performed to investigate the effect of changing geometries on the mechanical properties of the dental implant fixtures using stress analysis.

  15. Impact of a "TED-Style" presentation on potential patients' willingness to accept dental implant therapy: a one-group, pre-test post-test study

    PubMed Central

    Ghanem, Henry; Abi-Nader, Samer

    2015-01-01

    PURPOSE A survey was conducted to assess the impact of a TED-like educational session on participants' willingness to accept dental implant therapy. MATERIALS AND METHODS Volunteers interested in having information about dental implant therapies were recruited and asked to complete a two-part survey before and after an educational session. The initial survey elicited demographic information, self-perceived knowledge on dental implants and willingness to this kind of treatment. A "TED-style" presentation that provided information about dental implant treatments was conducted before asking the participants to complete a second set of questions assessing the impact of the session. RESULTS The survey was completed by 104 individuals, 78.8% were women and the mean age was 66.5±10.8. Before the educational session, 76.0% of the participants refused dental implants mainly due to lack of knowledge. After the educational session, the rejection of dental implants decreased by almost four folds to 20.2%. CONCLUSION This study proved that an educational intervention can significantly increase willingness to accept treatment with dental implants in a segment of the population who is interested in having information about dental implant therapy. Furthermore, educational interventions, such as TED-like talks, might be useful to increase popular awareness on dental implant therapy. PMID:26816573

  16. A study on setting of the fatigue limit of temporary dental implants.

    PubMed

    Kim, M H; Cho, E J; Lee, J W; Kim, E K; Yoo, S H; Park, C W

    2017-07-01

    A temporary dental implant is a medical device which is temporarily used to support a prosthesis such as an artificial tooth used for restoring patient's masticatory function during implant treatment. It is implanted in the oral cavity to substitute for the role of tooth. Due to the aging and westernization of current Korean society, the number of tooth extraction and implantation procedures is increasing, leading to an increase in the use and development of temporary dental implants. Because an implant performs a masticatory function in place of a tooth, a dynamic load is repeatedly put on the implant. Thus, the fatigue of implants is reported to be the most common causes of the fracture thereof. According to the investigation and analysis of the current domestic and international standards, the standard for fatigue of implant fixtures is not separately specified. Although a test method for measuring the fatigue is suggested in an ISO standard, it is a standard for permanent dental implants. Most of the test standards for Korean manufacturers and importers apply 250 N or more based on the guidance for the safety and performance evaluation of dental implants. Therefore, this study is intended to figure out the fatigue standard which can be applied to temporary dental implants when measuring the fatigue according to the test method suggested in the permanent dental implant standard. The results determined that suitable fatigue standards of temporary dental implants should be provided by each manufacturer rather than applying 250 N. This study will be useful for the establishment of the fatigue standards and fatigue test methods of the manufacturers and importers of temporary dental implants.

  17. Hybrid micro/nanostructural surface offering improved stress distribution and enhanced osseointegration properties of the biomedical titanium implant.

    PubMed

    Hou, Ping-Jen; Ou, Keng-Liang; Wang, Chin-Chieh; Huang, Chiung-Fang; Ruslin, Muhammad; Sugiatno, Erwan; Yang, Tzu-Sen; Chou, Hsin-Hua

    2018-03-01

    The aim of the present study was to investigate the surface characteristic, biomechanical behavior, hemocompatibility, bone tissue response and osseointegration of the optimal micro-arc oxidation surface-treated titanium (MST-Ti) dental implant. The surface characteristic, biomechanical behavior and hemocompatibility of the MST-Ti dental implant were performed using scanning electron microscope, finite element method, blood dripping and immersion tests. The mini-pig model was utilized to evaluate the bone tissue response and osseointegration of the MST-Ti dental implant in vivo. Data were analyzed by analysis of variance using the Student's t-test (P ≤ 0.05). The hybrid volcano-like micro/nanoporous structure was formed on the surface of the MST-Ti dental implant. The hybrid volcano-like micro/nanoporous surface played an important role to improve the stress transfer between fixture, cortical bone and cancellous bone for the MST-Ti dental implant. Moreover, the MST-Ti implant was considered to have the outstanding hemocompatibility. In vivo testing results showed that the bone-to-implant contact (BIC) ratio significantly altered as the implant with micro/nanoporous surface. After 12 weeks of implantation, the MST-Ti dental implant group exhibited significantly higher BIC ratio than the untreated dental implant group. In addition, the MST-Ti dental implant group also presented an enhancing osseointegration, particularly in the early stages of bone healing. It can be concluded that the micro-arc oxidation approach induced the formation of micro/nanoporous surface is a promising and reliable alternative surface modification for Ti dental implant applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Assessment and Evaluation of Quality of Life (OHRQoL) of Patients with Dental Implants Using the Oral Health Impact Profile (OHIP-14) - A Clinical Study.

    PubMed

    Alzarea, Bader K

    2016-04-01

    Peri-implant tissue health is a requisite for success of dental implant therapy. Plaque accumulation leads to initiation of gingivitis around natural teeth and peri-implantitis around dental implants. Peri-implantitis around dental implants may result in implant placement failure. For obtaining long-term success, timely assessment of dental implant site is mandatory. To assess and evaluate Quality of Life (OHRQoL) of individuals with dental implants using the Oral Health Impact Profile (OHIP-14). Total 92 patients were evaluated for assessment of the health of peri-implant tissues by recording, Plaque Index (PI), Probing Pocket Depth (PD), Bleeding On Probing (BOP) and Probing Attachment Level (PAL) as compared to contra-lateral natural teeth (control). In the same patients Quality of Life Assessment was done by utilizing Oral Health Impact Profile Index (OHIP-14). The mean plaque index around natural teeth was more compared to implants and it was statistically significant. Other three dimensions mean bleeding on probing; mean probing attachment level and mean pocket depth around both natural teeth and implant surfaces was found to be not statistically significant. OHIP-14 revealed that patients with dental implants were satisfied with their Oral Health-Related Quality of Life (OHRQoL). Similar inflammatory conditions are present around both natural teeth and implant prostheses as suggested by results of mean plaque index, mean bleeding on probing, mean pocket depth and mean probing attachment level, hence reinforcing the periodontal health maintenance both prior to and after incorporation of dental implants. Influence of implant prostheses on patient's oral health related quality of life (as depicted by OHIP-14) and patients' perceptions and expectations may guide the clinician in providing the best implant services.

  19. Quality of YouTube TM videos on dental implants.

    PubMed

    Abukaraky, A; Hamdan, A-A; Ameera, M-N; Nasief, M; Hassona, Y

    2018-07-01

    Patients search YouTube for health-care information. To examine what YouTube offers patients seeking information on dental implants, and to evaluate the quality of provided information. A systematic search of YouTube for videos containing information on dental implants was performed using the key words Dental implant and Tooth replacement. Videos were examined by two senior Oral and Maxillofacial Surgery residents who were trained and calibrated to perform the search. Initial assessment was performed to exclude non- English language videos, duplicate videos, conference lectures, and irrelevant videos. Included videos were analyzed with regard to demographics and content's usefulness. Information for patients available from the American Academy of Implant Dentistry, European Association of Osseointegration, and British Society of Restorative Dentistry were used for benchmarking. A total of 117 videos were analyzed. The most commonly discussed topics were related to procedures involved in dental implantology (76.1%, n=89), and to the indications for dental implants (58.1%, n=78). The mean usefulness score of videos was poor (6.02 ±4.7 [range 0-21]), and misleading content was common (30.1% of videos); mainly in topics related to prognosis and maintenance of dental implants. Most videos (83.1%, n=97) failed to mention the source of information presented in the video or where to find more about dental implants. Information about dental implants on YouTube is limited in quality and quantity. YouTube videos can have a potentially important role in modulating patients attitude and treatment decision regarding dental implants.

  20. Maxillary implant-retained partial overdenture with Dolder bar attachment: a clinical report.

    PubMed

    Kim, Hyeongil; Buhite, Robert J; Monaco, Edward A

    2015-03-01

    This article describes a technique for maintaining a maxillary Kennedy III partial removable dental prosthesis design in a patient who had non-restorable failing abutments by replacing the abutments with dental implants. Two implants were placed immediately after extraction of the abutment teeth in the anterior maxilla. After the implants were fully integrated, a Dolder bar attachment was fitted onto the implants. A new maxillary partial removable dental prosthesis was fabricated using the implants and the remaining natural teeth as abutments to restore function and esthetics. With the aid of dental implants, this Kennedy III maxillary removable dental prosthesis design could provide additional retention and support by promoting cross-arch stability and tissue, implant and tooth support. The patient's satisfaction was significantly increased.

  1. Dental Implant Systems

    PubMed Central

    Oshida, Yoshiki; Tuna, Elif B.; Aktören, Oya; Gençay, Koray

    2010-01-01

    Among various dental materials and their successful applications, a dental implant is a good example of the integrated system of science and technology involved in multiple disciplines including surface chemistry and physics, biomechanics, from macro-scale to nano-scale manufacturing technologies and surface engineering. As many other dental materials and devices, there are crucial requirements taken upon on dental implants systems, since surface of dental implants is directly in contact with vital hard/soft tissue and is subjected to chemical as well as mechanical bio-environments. Such requirements should, at least, include biological compatibility, mechanical compatibility, and morphological compatibility to surrounding vital tissues. In this review, based on carefully selected about 500 published articles, these requirements plus MRI compatibility are firstly reviewed, followed by surface texturing methods in details. Normally dental implants are placed to lost tooth/teeth location(s) in adult patients whose skeleton and bony growth have already completed. However, there are some controversial issues for placing dental implants in growing patients. This point has been, in most of dental articles, overlooked. This review, therefore, throws a deliberate sight on this point. Concluding this review, we are proposing a novel implant system that integrates materials science and up-dated surface technology to improve dental implant systems exhibiting bio- and mechano-functionalities. PMID:20480036

  2. Prognosis after treatment with multiple dental implants under general anesthesia and sedation in a cerebral palsy patient with mental retardation: A case report.

    PubMed

    Hong, Young-Joon; Dan, Jung-Bae; Kim, Myung-Jin; Kim, Hyun Jeong; Seo, Kwang-Suk

    2017-06-01

    Cerebral palsy is a non-progressive disorder resulting from central nervous system damage caused by multiple factors. Almost all cerebral palsy patients have a movement disorder that makes dental treatment difficult. Oral hygiene management is difficult and the risks for periodontitis, dental caries and loss of multiple teeth are high. Placement of dental implants for multiple missing teeth in cerebral palsy patients needs multiple rounds of general anesthesia, and the prognosis is poor despite the expense. Therefore, making the decision to perform multiple dental implant treatments on cerebral palsy patients is difficult. A 33-year-old female patient with cerebral palsy and mental retardation was scheduled for multiple implant treatments. She underwent computed tomography (CT) under sedation and the operation of nine dental implants under general anesthesia. Implant-supported fixed prosthesis treatment was completed. During follow-up, she had the anterior incisors extracted and underwent the surgery of 3 additional dental implants, completing the prosthetic treatment. Although oral parafunctions existed due to cerebral palsy, no implant failure was observed 9 years after the first implant surgery.

  3. Short dental implants: A scoping review of the literature for patients with head and neck cancer.

    PubMed

    Edher, Faraj; Nguyen, Caroline T

    2017-09-16

    Dental implants can be essential in the rehabilitation of various cancer defects, but their ideal placement can be complicated by the limited dimensions of the available host bone. Surgical interventions developed to increase the amount of bone are not all predictable or successful and can sometimes be contraindicated. Short dental implants have been suggested as an alternative option in sites where longer implants are not possible. Whether they provide a successful treatment option is unclear. The purpose of this study was to review the literature on short dental implants and assess whether they are a viable definitive treatment option for rehabilitating cancer patients with deficient bone. A scoping review of the literature was performed, including a search of established periodontal textbooks for articles on short dental implants combined with a search of PubMed, MEDLINE, EMBASE, Web of Science, and Cochrane Database of Systematic Reviews. A search for all literature published before June 2016 was based on the following keywords: ['dental implants' OR 'dental implantation, endosseous' OR 'dental prosthesis, implant supported'] AND [short]. The minimum acceptable implant length has been considered to be 6 mm. The survival rates of short implants varied between 74% and 96% at 5 years, depending on factors such as the quality of the patient's bone, primary stability of the implant, clinician's learning curve, and implant surface. Short implants can achieve results similar to those of longer implants in augmented bone and offer a treatment alternative that could reduce the need for invasive surgery and associated morbidity and be safer and more economical. Short dental implants (6 mm to 8 mm) can be used successfully to support single or multiple fixed reconstructions or overdentures in atrophic maxillae and mandibles. The use of short dental implants lessens the need for advanced and complicated surgical bone augmentation procedures, which reduces complications, costs, treatment time, and morbidity. Short implants could be an alternative in the rehabilitation of patients with cancer. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Subgingival Microbiome Colonization and Cytokine Production during Early Dental Implant Healing.

    PubMed

    Payne, Jeffrey B; Johnson, Paul G; Kok, Car Reen; Gomes-Neto, João C; Ramer-Tait, Amanda E; Schmid, Marian J; Hutkins, Robert W

    2017-01-01

    Little is known about longitudinal development of the peri-implant subgingival microbiome and cytokine production as a new sulcus forms after dental implant placement. Therefore, the purpose of this observational study was to evaluate simultaneous longitudinal changes in the oral microbiome and cytokine production in the developing peri-implant sulcus compared to control natural teeth. Four and 12 weeks after implant placement and abutment connection, a dental implant and a natural tooth were sampled in 25 patients for subgingival plaque and gingival crevicular fluid (GCF [around teeth] and peri-implant crevicular fluid [PICF] around implants). DNA from plaque samples was extracted and sequenced using Illumina-based 16S rRNA sequencing. GCF and PICF samples were analyzed using a customized Milliplex human cytokine and chemokine magnetic bead panel. Beta diversity analysis revealed that natural teeth and implants had similar subgingival microbiomes, while teeth had greater alpha diversity than implants. At the genus level, however, few differences were noted between teeth and dental implants over 12 weeks. Specifically, Actinomyces and Selenomonas were significantly elevated around teeth versus dental implants at both 4 weeks and 12 weeks, while Corynebacterium and Campylobacter were significantly elevated only at 4 weeks around teeth. The only difference between PICF and GCF biomarkers was significantly elevated granulocyte-macrophage colony-stimulating factor levels around teeth versus dental implants at the 4-week visit. The subgingival microbiome and cytokine production were similar between teeth and implants during early healing, suggesting that these profiles are driven by the patient following dental implant placement and are not determined by anatomical niche. IMPORTANCE Dental implants are a common treatment option offered to patients for tooth replacement. However, little is known regarding initial colonization of the subgingival microbiome and simultaneous longitudinal cytokine production in humans during the early healing phase following implant placement. We report findings from an in vivo study that assessed initial colonization of the subgingival microbiome and concomitant early cytokine production in a newly formed anatomical space, namely, an implant sulcus. This approach may be useful in future interventional studies to influence dental implant success. Our data showed that the subgingival microbiome and cytokine profile were similar for control natural teeth and dental implants at both 4 and 12 weeks after implant placement. These data suggest that these profiles are driven by the patient and not by anatomical location (i.e., tooth versus dental implant).

  5. Assessment of Myeloperoxidase and Nitric Levels around Dental Implants and Natural Teeth as a Marker of Inflammation: A Comparative Study.

    PubMed

    Kulkarni, Gayithri H; Jadhav, Prashant; Kulkarni, Kiran; Shinde, Sachin V; Patil, Yojana B; Kumar, Manish

    2016-11-01

    Dental implants form the mainstay of dental treatment involving rehabilitation of missing teeth. One of the major concerns for the clinicians doing dental implants is the postsurgical failure of dental implants. Success of dental implants is dependent upon the skills of the surgeon and the amount and quality of the bone remaining at the edentulous area where dental implant has to be placed. Myeloperoxidase (MPO) and nitrites are few of the enzymes and molecules which are said to be altered in inflammation. However, their exact role in the inflammatory processes around natural tooth and dental implant is still unclear. Hence we comparatively evaluated the levels of MPO and nitrites in the areas around the dental implants and natural teeth. The present study comprises 42 patients who underwent prosthetic rehabilitation by dental implants from 2011 to 2014. Depth of probing value (DP), score of plaque index (SPI), gingival index (GI), and index of gingival bleeding time (GBT) were evaluated for the assessment of the periimplant soft tissue changes. Assessment of inflammation around the dental implant surface and around natural tooth was done based on the readings of these parameters. For the measurement of the MPO levels, spectrophotometric MPO assay was used. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. The mean plaque index values were 1.56 and 0.97 in periodontitis cases of natural teeth and inflamed cases of dental implants respectively. While comparing mean plaque index, mean probing depth, and mean gingival bleeding index in between the two groups, significant difference was obtained. Mean MPO concentration in periodontitis and gingivitis cases in natural teeth were 0.683 and 0.875 U/μL, while in inflamed dental implant cases, the mean value was 0.622 U/μL. While comparing the total MPO levels, total nitrite levels, and total nitrite concentration in between two study groups, significant difference was obtained. On comparing the healthy and periodontitis cases in natural teeth, significant difference was obtained. In the inflammatory processes occurring around dental implant and natural teeth, MPO and NO make some amount of significant contribution. The present study enforces on the role of MPO and nitrite as diagnostic and prognostic marker.

  6. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis.

    PubMed

    Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza

    2016-04-01

    The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.

  7. 10-year survival rate and the incidence of peri-implant disease of 374 titanium dental implants with a SLA surface: a prospective cohort study in 177 fully and partially edentulous patients.

    PubMed

    van Velzen, Frank J J; Ofec, Ronen; Schulten, Engelbert A J M; Ten Bruggenkate, Christiaan M

    2015-10-01

    This prospective cohort study evaluates the 10-year survival and incidence of peri-implant disease at implant and patient level of sandblasted, large grid, and acid-etched titanium dental implants (Straumann, soft tissue level, SLA surface) in fully and partially edentulous patients. Patients who had dental implant surgery in the period between November 1997 and June 2001, with a follow-up of at least 10 years, were investigated for clinical and radiological examination. Among the 506 inserted dental implants in 250 patients, 10-year data regarding the outcome of implants were available for 374 dental implants in 177 patients. In the current study, peri-implantitis was defined as advanced bone loss (≧1.5 mm. postloading) in combination with bleeding on probing. At 10-year follow-up, only one implant was lost (0.3%) 2 months after implant surgery due to insufficient osseointegration. The average bone loss at 10 year postloading was 0.52 mm. Advanced bone loss at 10-year follow-up was present in 35 dental implants (9.8%). Seven percent of the observed dental implants showed bleeding on probing in combination with advanced bone loss and 4.2% when setting the threshold for advanced bone loss at 2.0 mm. Advanced bone loss without bleeding on probing was present in 2.8% of all implants. In this prospective study, the 10-year survival rate at implant and patient level was 99.7% and 99.4%, respectively. Peri-implantitis was present in 7% of the observed dental implants according to the above-mentioned definition of peri-implantitis. This study shows that SLA implants offer predictable long-term results as support in the treatment of fully and partially edentulous patients. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. PEEK with Reinforced Materials and Modifications for Dental Implant Applications

    PubMed Central

    Rahmitasari, Fitria; Ishida, Yuichi; Kurahashi, Kosuke; Matsuda, Takashi; Watanabe, Megumi

    2017-01-01

    Polyetheretherketone (PEEK) is a semi-crystalline linear polycyclic thermoplastic that has been proposed as a substitute for metals in biomaterials. PEEK can also be applied to dental implant materials as a superstructure, implant abutment, or implant body. This article summarizes the current research on PEEK applications in dental implants, especially for the improvement of PEEK surface and body modifications. Although various benchmark reports on the reinforcement and surface modifications of PEEK are available, few clinical trials using PEEK for dental implant bodies have been published. Controlled clinical trials, especially for the use of PEEK in implant abutment and implant bodies, are necessary. PMID:29563441

  9. PEEK with Reinforced Materials and Modifications for Dental Implant Applications.

    PubMed

    Rahmitasari, Fitria; Ishida, Yuichi; Kurahashi, Kosuke; Matsuda, Takashi; Watanabe, Megumi; Ichikawa, Tetsuo

    2017-12-15

    Polyetheretherketone (PEEK) is a semi-crystalline linear polycyclic thermoplastic that has been proposed as a substitute for metals in biomaterials. PEEK can also be applied to dental implant materials as a superstructure, implant abutment, or implant body. This article summarizes the current research on PEEK applications in dental implants, especially for the improvement of PEEK surface and body modifications. Although various benchmark reports on the reinforcement and surface modifications of PEEK are available, few clinical trials using PEEK for dental implant bodies have been published. Controlled clinical trials, especially for the use of PEEK in implant abutment and implant bodies, are necessary.

  10. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    PubMed

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  11. Differences in knowledge related to dental implants between patients with and without a treatment history of dental implants.

    PubMed

    Ken, Yukawa; Tachikawa, Noriko; Kasugai, Shohei

    2017-09-01

    This aim of this study was to investigate the differences between patients with and without a treatment history of dental implants by use of a questionnaire survey in order to determine the information that is required for patients undergoing dental implants. The questionnaires were given to 4512 patients who visited the Tokyo Medical and Dental University Hospital for oral implants between January 2012 and December 2014, and 2972 (66%) valid questionnaires were collected. There were 857 patients with a treatment history of dental implants and 2115 patients without. "Preservation of an adjacent tooth" was the reason that 32% of these patients chose implant therapy, and the patients without treatment history were significantly higher than the patients with one. Significantly, more patients without a treatment history of dental implants selected the after-effects of surgery and pain after surgery as their main concerns for implant therapy compared to those with a treatment history. In the question "Pain after surgery," the patients without treatment history did not know significantly lower than the patients with one. Patients without a treatment history of dental implants placed more importance on the preservation of healthy teeth. Because patients, in particular those without a treatment history of dental implants, are anxious about surgery, we should provide them with more information on treatment than we already do and explain the risks of treatment to them. To keep the credence between doctors and patients, informed consent and patient education on treatment are six important concerns. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Implant dentistry curriculum in undergraduate education: part 2-program at the Albert-Ludwigs University, Freiburg, Germany.

    PubMed

    Kroeplin, Birgit S; Strub, Joerg R

    2011-01-01

    The aim of this study was to describe the didactic and clinical undergraduate implant dentistry program of the Albert-Ludwigs University, Freiburg, Germany, with emphasis on the clinical implant experience. A detailed description of the implant curriculum at Albert-Ludwigs University is given with documented exemplary cases and additional flow charts. All students participate in 28 hours of lectures and approximately 64 hours of seminars with hands-on courses and gain clinical experience. All undergraduate students are eligible to place and restore oral implants. Emphasis is placed on prosthetic-driven planning of implant positions, three-dimensional imaging, and computer-guided implant placement. Implant restorations performed by undergraduate students comprise single crowns and small multiunit fixed dental prostheses in partially edentulous posterior maxillae and anterior or posterior mandibles, implant-retained overdentures (snap attachment) in edentulous patients, and telescopic fixed-removable dental prostheses on remaining teeth and strategically placed additional implants. Over the past 2.5 years, 51 patients were treated with 97 dental implants placed by students in the undergraduate program. Seventy-one restorations were inserted: 60.6% single crowns, 7% fixed dental protheses, 21.1% overdentures, and 11.3% telescopic fixed-removable dental prostheses. The implant survival rate was 98.9%. Because survival rates for dental implants placed and restored by students are comparable to those of experienced dentists, oral implant dentistry should be implemented as part of the undergraduate dental curriculum.

  13. Dual-modal photoacoustic and ultrasound imaging of dental implants

    NASA Astrophysics Data System (ADS)

    Lee, Donghyun; Park, Sungjo; Kim, Chulhong

    2018-02-01

    Dental implants are common method to replace decayed or broken tooth. As the implant treatment procedures varies according to the patients' jawbone, bone ridge, and sinus structure, appropriate examinations are necessary for successful treatment. Currently, radiographic examinations including periapical radiology, panoramic X-ray, and computed tomography are commonly used for diagnosing and monitoring. However, these radiographic examinations have limitations in that patients and operators are exposed to radioactivity and multiple examinations are performed during the treatment. In this study, we demonstrated photoacoustic (PA) and ultrasound (US) combined imaging of dental implant that can lower the total amount of absorbed radiation dose in dental implant treatment. An acoustic resolution PA macroscopy and a clinical PA/US system was used for dental implant imaging. The acquired dual modal PA/US imaging results support that the proposed photoacoustic imaging strategy can reduce the radiation dose rate during dental implant treatment.

  14. Preliminary fabrication and characterization of electron beam melted Ti-6Al-4V customized dental implant.

    PubMed

    Ramakrishnaiah, Ravikumar; Al Kheraif, Abdulaziz Abdullah; Mohammad, Ashfaq; Divakar, Darshan Devang; Kotha, Sunil Babu; Celur, Sree Lalita; Hashem, Mohamed I; Vallittu, Pekka K; Rehman, Ihtesham Ur

    2017-05-01

    The current study was aimed to fabricate customized root form dental implant using additive manufacturing technique for the replacement of missing teeth. The root form dental implant was designed using Geomagic™ and Magics™, the designed implant was directly manufactured by layering technique using ARCAM A2™ electron beam melting system by employing medical grade Ti-6Al-4V alloy powder. Furthermore, the fabricated implant was characterized in terms of certain clinically important parameters such as surface microstructure, surface topography, chemical purity and internal porosity. Results confirmed that, fabrication of customized dental implants using additive rapid manufacturing technology offers an attractive method to produce extremely pure form of customized titanium dental implants, the rough and porous surface texture obtained is expected to provide better initial implant stabilization and superior osseointegration.

  15. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1985-11-15

    development of dental implantology must not be overlooked. The early stages of this project clearly defined that rigid fixation of an implant device...block number) .-... This report summarizes progress on a long-ter implant study of a serrated ceramic dental implant designed for fresh extraction...implant, post and core and crown, are conventional metal materials, A series of graded dental implants have been produced to provide an interference fit

  16. Development and Applications of Porous Tantalum Trabecular Metal Enhanced Titanium Dental Implants

    PubMed Central

    Bencharit, Sompop; Byrd, Warren C.; Altarawneh, Sandra; Hosseini, Bashir; Leong, Austin; Reside, Glenn; Morelli, Thiago; Offenbacher, Steven

    2013-01-01

    Statement of Problem Porous tantalum trabecular metal has recently been incorporated in titanium dental implants as a new form of implant surface enhancement. However, there is little information on the applications of this material in implant dentistry. Methods We, therefore review the current literature on the basic science and clinical uses of this material. Results Porous tantalum metal is used to improve the contact between osseous structure and dental implants; and therefore presumably facilitate osseointegration. Success of porous tantalum metal in orthopedic implants led to the incorporation of porous tantalum metal in the design of root-from endosseous titanium implants. The porous tantalum three-dimensional enhancement of titanium dental implant surface allows for combining bone ongrowth together with bone ingrowth, or osseoincorporation. While little is known about the biological aspect of the porous tantalum in the oral cavity, there seems to be several possible advantages of this implant design. This article reviews the biological aspects of porous tantalum enhanced titanium dental implants, in particular the effects of anatomical consideration and oral environment to implant designs. Conclusions We propose here possible clinical situations and applications for this type of dental implant. Advantages and disadvantages of the implants as well as needed future clinical studies are discussed. PMID:23527899

  17. Methods to Improve Osseointegration of Dental Implants in Low Quality (Type-IV) Bone: An Overview.

    PubMed

    Alghamdi, Hamdan S

    2018-01-13

    Nowadays, dental implants have become more common treatment for replacing missing teeth and aim to improve chewing efficiency, physical health, and esthetics. The favorable clinical performance of dental implants has been attributed to their firm osseointegration, as introduced by Brånemark in 1965. Although the survival rate of dental implants over a 10-year observation has been reported to be higher than 90% in totally edentulous jaws, the clinical outcome of implant treatment is challenged in compromised (bone) conditions, as are frequently present in elderly people. The biomechanical characteristics of bone in aged patients do not offer proper stability to implants, being similar to type-IV bone (Lekholm & Zarb classification), in which a decreased clinical fixation of implants has been clearly demonstrated. However, the search for improved osseointegration has continued forward for the new evolution of modern dental implants. This represents a continuum of developments spanning more than 20 years of research on implant related-factors including surgical techniques, implant design, and surface properties. The methods to enhance osseointegration of dental implants in low quality (type-IV) bone are described in a general manner in this review.

  18. Stress Analysis on the Bone Around Five Different Dental Implants

    DTIC Science & Technology

    2001-10-25

    University of Science and Technology, Tehran, IRAN Abstract- Implantology has a widespread application in dental cases these days. Although the life...System, in Mackinny RV: Endosteal Dental Implant, Mosby Year Book, 1991 [3] Weiss M, Titanium Fiber-Mesh Metal Implant, J. Oral Implantology , 1986...STRESS ANALYSIS ON THE BONE AROUND FIVE DIFFERENT DENTAL IMPLANTS S. M. Rajaai, S. Khorrami-mehr School of mechanical Engineering Iran

  19. Effect on Bone Architecture of Marginal Grooves in Dental Implants Under Occlusal Loaded Conditions in Beagle Dogs.

    PubMed

    Kato, Hatsumi; Kuroshima, Shinichiro; Inaba, Nao; Uto, Yusuke; Sawase, Takashi

    2018-02-01

    The aim of this study was to clarify whether marginal grooves on dental implants affect osseointegration, bone structure, and the alignment of collagen fibers to determine bone quality under loaded conditions. Anodized Ti-6Al-4V alloy dental implants, with and without marginal grooves (test and control implants, respectively), were used (3.7 × 8.0 mm). Fourth premolars and first molars of 6 beagle mandibles were extracted. Two control and test implants were placed in randomly selected healed sites at 12 weeks after tooth extraction. Screw-retained single crowns for first molars were fabricated. Euthanasia was performed at 8 weeks after the application of occlusal forces. Implant marginal bone level, bone to implant contact (BIC), bone structure around dental implants, and the alignment of collagen fibers determining bone quality were analyzed. The marginal bone level in test implants was significantly higher than that in control implants. Occlusal forces significantly increased BIC in test implants ( P = .007), whereas BIC did not change in control implants, irrespective of occlusal forces ( P = .303). Moreover, occlusal forces significantly increased BIC in test implants compared with control implants ( P = .032). Additionally, occlusal forces preferentially aligned collagen fibers in test implants, but not control implants. Hence, marginal grooves on dental implants have positive effects on increased osseointegration and adapted bone quality based on the preferential alignment of collagen fibers around dental implants under loaded conditions.

  20. What do patients expect from treatment with Dental Implants? Perceptions, expectations and misconceptions: a multicenter study.

    PubMed

    Yao, Jie; Li, Ming; Tang, Hua; Wang, Peng-Lai; Zhao, Yu-Xiao; McGrath, Colman; Mattheos, Nikos

    2017-03-01

    While research in terms of patient-centered care in implant therapy is growing, few studies have investigated patients' initial perceptions prior to consultation with the implant dentist. The aim of this cross-sectional study was to capture patients' initial information level, perceptions, as well as expectations from the implant therapy. A 34-item questionnaire was developed to investigate patients' preoperative information, perceptions and expectations from treatment with Dental Implants. The study was conducted in three locations (Hong Kong, SiChuan and JiangSu) during 2014-2015 with 277 patients. The main information source about implant therapy was the dentist or hygienist for less than half of the patients (n = 113, 42%). About 62.8% of participants considered that they were in general informed about implants, but only 17.7% felt confident with the information they had. More than 30% of the sample appeared to maintain dangerous misperceptions about Dental Implants: "Dental Implants require less care than natural teeth"; "Treatment with Dental Implants is appropriate for all patients with missing teeth"; "Dental Implants last longer than natural teeth"; and "Treatments with Dental Implants have no risks or complications." Patients were divided when asked whether "Dental Implants are as functional as natural teeth" (agreement frequency = 52.7%). Expectations from treatment outcome were commonly high, while there was a significant correlation between the overall mean of perception scores and outcome expectation scores (r = 0.32, P < 0.001). Overall, younger subjects (<45 years) and those with higher education level (bachelor and postgraduate) tended to present more realistic perceptions and lower outcome expectations. The majority of patients in this study presented relatively realistic perceptions. However, an alarming portion of the sample presented with inaccurate perceptions and unrealistic expectations, which the dental team would need to diagnose and correct prior to initiating implant treatment. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Incidence and Determinants of Dental Implant Failure: A Review of Electronic Health Records in a U.S. Dental School.

    PubMed

    Hickin, Matthew Parker; Shariff, Jaffer A; Jennette, Philip J; Finkelstein, Joseph; Papapanou, Panos N

    2017-10-01

    The aim of this study was to use electronic health care records (EHRs) to examine retrospectively the incidence of and attributes associated with dental implant failures necessitating implant removal in a large cohort of patients treated in the student clinics of a U.S. dental school over three and a half years. EHRs were searched for all patients who received dental implants between July 1, 2011, and December 31, 2014. Characteristics of patients and implants that were actively removed due to irrevocable failure of any etiology ("failure cohort") during this period were compared to those of all other patients who received dental implants during the same time frame ("reference cohort"). Differences in the frequency distribution of various characteristics between the failure and reference cohorts were compared. Of a total 6,129 implants placed in 2,127 patients during the study period, 179 implants (2.9%) in 120 patients (5.6%) were removed. In the multivariate analysis, presence of a removable (OR=2.86) or fixed temporary prosthesis (OR=3.71) was statistically significantly associated with increased risk for implant failure. In contrast, antibiotic coverage (pre- and post-surgery OR=0.16; post-surgery only OR=0.38) and implants of certain manufacturers were associated with lower risk of implant failure. In this sizeable cohort of patients receiving care in dental student clinics, the review of EHRs facilitated identification of multiple variables associated with implant failure resulting in removal; however, these findings do not suggest causative relationships. The adopted analytical approach can enhance quality assurance measures and may contribute to the identification of true risk factors for dental implant failure.

  2. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1984-07-15

    and identify by block number) --- This Annual Report summarizes progress to date on a long-term implant study of a serrated ceramic dental implant...upper two parts of the implant, post and core and crown, are conventional metaT materials. A series of graded dental implants have been produced to...throughout the experimental period. Periodic radio- graphic analyses of dental implants verify this observation. Gross and microscopic patho- logic analyses

  3. Prevalence of Dental Implants and Evaluation of Peri-implant Bone Levels in Patients Presenting to a Dental School: A Radiographic Cross-Sectional 2-Year Study.

    PubMed

    Alkan, Eylem Ayhan; Mau, Lian Ping; Schoolfield, John; Guest, Gary F; Cochran, David L

    To evaluate the number of patients with dental implants who present to a dental school clinic for screening and to report the prevalence of peri-implant bone level change detected on digital panoramic radiographs of those subjects. Patient screening files for 9,422 patients over a 2-year period were examined to see how many patients presented with dental implants. Those patients with at least one implant were further evaluated by measuring the bone level on the mesial and distal sides of the implant using the screening radiograph. A total of 187 patients (2%) had at least one implant. In regard to implants, 423 were examined and 146 (33%) had no detectable bone loss defined as bone level below the top of the implant. When thresholds of bone loss were evaluated, 109 implants (25%) had ≥ 2 mm of bone loss on either the mesial or distal sides or both. The median bone loss was 1.74 mm for the 277 implants with detectable bone loss and 2.97 mm for the 109 implants that had ≥ 2 mm bone loss. Interestingly, patients who were ≥ 70 years of age had significantly (P = .03) more bone loss in the mandible compared with the maxilla, while patients who were 60 to 69 years of age had significantly greater loss in the maxilla. These data reveal that for patients presenting to the dental school for a screening over a 2-year period, 1.98% had one or more dental implants. Furthermore, those patients with implants had a minimum amount of bone loss as measured from the top of the implant.

  4. Cost-Effectiveness of Dental Implants: A Utility Analysis.

    ERIC Educational Resources Information Center

    Jacobson, J.; And Others

    1990-01-01

    A measure of dental patients' values and preferences was used to assess attitudes of 92 edentulous patients receiving implant and other dental reconstructive therapies. The implant group tended to be younger and better educated and to rate implant reconstruction as more desirable than the nonimplant denture group. (DB)

  5. In vitro biological outcome of laser application for modification or processing of titanium dental implants.

    PubMed

    Hindy, Ahmed; Farahmand, Farzam; Tabatabaei, Fahimeh Sadat

    2017-07-01

    There are numerous functions for laser in modern implant dentistry including surface treatment, surface coating, and implant manufacturing. As laser application may potentially improve osseointegration of dental implants, we systematically reviewed the literature for in vitro biological responses to laser-modified or processed titanium dental implants. The literature was searched in PubMed, ISI Web, and Scopus, using keywords "titanium dental implants," "laser," "biocompatibility," and their synonyms. After screening the 136 references obtained, 28 articles met the inclusion criteria. We found that Nd:YAG laser was the most commonly used lasers in the treatment or processing of titanium dental implants. Most of the experiments used cell attachment and cell proliferation to investigate bioresponses of the implants. The most commonly used cells in these assays were osteoblast-like cells. Only one study was conducted in stem cells. These in vitro studies reported higher biocompatibility in laser-modified titanium implants. It seems that laser radiation plays a vital role in cell response to dental implants; however, it is necessary to accomplish more studies using different laser types and parameters on various cells to offer a more conclusive result.

  6. Antibiotic prophylaxis patterns of Finnish dentists performing dental implant surgery.

    PubMed

    Pyysalo, Mikko; Helminen, Mika; Antalainen, Anna-Kaisa; Sándor, George K; Wolff, Jan

    2014-11-01

    The peri-operative use of prophylactic antibiotics in clinically healthy patients undergoing dental implant surgery is very common in Finland. While antibiotics are prescribed with the hope of preventing both local and systemic complications, their application and utilization is not uniform. The aim of this study was to assess the variation in prescribing patterns among Finnish dentists performing dental implant placement operations. This study also aimed to examine the possible relationship between early implant removal and the use of the prophylactic antibiotics in Finland. The National Institute for Health and Welfare in Finland granted permission to access the Finnish Dental Implant Register. The peri-operative antibiotic prophylaxis prescribing patterns were assessed in a total of 110 543 dental implant placement procedures and 1038 dental implant removal operations performed in Finland between April 1994 and April 2012. A total of 61 different antibiotics or combinations were prescribed peri-operatively during implant placements in Finland between 1994-2012. Phenoxymethylpenicillin was the most commonly prescribed drug (72.2%). No statistically significant difference in early implant removal rates could be found between patients who had or had not received peri-operative prophylaxis. However, patients who had received peri-operative prophylaxis had statistically significant longer implant survival rates. There is a variation in antibiotic prescribing patterns among Finnish dentists placing dental implants. The results suggest that the use of prophylactic antibiotics has little effect on the prevention of primary implant surgery-related complications and, hence, success rates.

  7. Automated dental implantation using image-guided robotics: registration results.

    PubMed

    Sun, Xiaoyan; McKenzie, Frederic D; Bawab, Sebastian; Li, Jiang; Yoon, Yongki; Huang, Jen-K

    2011-09-01

    One of the most important factors affecting the outcome of dental implantation is the accurate insertion of the implant into the patient's jaw bone, which requires a high degree of anatomical accuracy. With the accuracy and stability of robots, image-guided robotics is expected to provide more reliable and successful outcomes for dental implantation. Here, we proposed the use of a robot for drilling the implant site in preparation for the insertion of the implant. An image-guided robotic system for automated dental implantation is described in this paper. Patient-specific 3D models are reconstructed from preoperative Cone-beam CT images, and implantation planning is performed with these virtual models. A two-step registration procedure is applied to transform the preoperative plan of the implant insertion into intra-operative operations of the robot with the help of a Coordinate Measurement Machine (CMM). Experiments are carried out with a phantom that is generated from the patient-specific 3D model. Fiducial Registration Error (FRE) and Target Registration Error (TRE) values are calculated to evaluate the accuracy of the registration procedure. FRE values are less than 0.30 mm. Final TRE values after the two-step registration are 1.42 ± 0.70 mm (N = 5). The registration results of an automated dental implantation system using image-guided robotics are reported in this paper. Phantom experiments show that the practice of robot in the dental implantation is feasible and the system accuracy is comparable to other similar systems for dental implantation.

  8. A 6-month study of the effects of 0.3% triclosan/copolymer dentifrice on dental implants.

    PubMed

    Sreenivasan, Prem K; Vered, Yuval; Zini, Avi; Mann, Jonathan; Kolog, Hilla; Steinberg, Doron; Zambon, Joseph J; Haraszthy, Violet I; da Silva, Maike P; De Vizio, William

    2011-01-01

    Supportive therapy to maintain dental implants is increasingly important. This study examined the effect of a 0.3% triclosan/2% copolymer dentifrice on oral biofilms and gingival inflammation (GI) on dental implants and peri-implant tissues. One hundred and twenty adults with a dental implant and contra-lateral tooth were enrolled in this 6 month, double-blind, two-treatment, parallel group study. Sixty subjects were randomly assigned to a triclosan/copolymer dentifrice test group and 60 subjects to a fluoride dentifrice control group and instructed to brush twice daily for 6 months. At baseline, 3, and 6 months, a calibrated dentist assessed dental plaque, GI and collected supragingival dental plaque for microbiological analysis. Subjects in the triclosan/copolymer group demonstrated significantly lower levels of dental plaque, gingivitis, and bleeding on probing at 3 and 6 months at both the implant and contra-lateral tooth compared with the fluoride group (p<0.05). There were significantly fewer Gram-negative anaerobes in the triclosan/copolymer group (p<0.05) including >90% reductions in Aggregatibacter actinomycetemcomitans, Campylobacter rectus, Eubacterium saburreum, Fusobacterium nucleatum, Porphyromonas gingivalis, Prevotella melaninogenica, Solobacterium moorei, and Tannerella forsythia. Twice daily use of a triclosan/copolymer dentifrice may enhance dental implant maintenance by reducing dental plaque and GI. © 2010 John Wiley & Sons A/S.

  9. Smoking increases salivary arginase activity in patients with dental implants.

    PubMed

    Queiroz, D A; Cortelli, J R; Holzhausen, M; Rodrigues, E; Aquino, D R; Saad, W A

    2009-09-01

    It is believed that an increased arginase activity may lead to less nitric oxide production, which consequently increases the susceptibility to bacterial infection. Considering the hypothesis that smoking may alter the arginase activity and that smoking is considered a risk factor to dental implant survival, the present study aimed at evaluating the effect of smoking on the salivary arginase activity of patients with dental implants. Salivary samples of 41 subjects were collected: ten non-smoking and with no dental implants (group A), ten non-smoking subjects with dental implants (group B), ten smoking subjects with implants (group C), and 11 smoking subjects with no dental implants (group D). The levels of salivary arginase activity were determined by the measurement of L-ornithine and expressed as mIU/mg of protein. A significant increase in the salivary arginase activity was verified in groups C (64.26 +/- 16.95) and D (49.55 +/- 10.01) compared to groups A (10.04 +/- 1.95, p = 0.00001 and p = 0.0110, groups C and D, respectively) and B (11.77 +/- 1.45, p = 0.00001 and p = 0.0147, groups C and D, respectively). No significant difference was found between groups C and D (p = 0.32). Within the limits of the present study, it can be concluded that salivary arginase activity is increased in smoking subjects with dental implants in contrast to non-smoking subjects with dental implants, therefore suggesting a possible mechanism by which cigarette smoking may lead to implant failure. The analysis of salivary arginase activity may represent an important tool to prevent implant failure in the near future.

  10. Adherent endotoxin on dental implant surfaces: a reappraisal.

    PubMed

    Morra, Marco; Cassinelli, Clara; Bollati, Daniele; Cascardo, Giovanna; Bellanda, Marco

    2015-02-01

    Osteoimmunology is the crosstalk between cells from the immune and skeletal systems, suggesting a role of pro-inflammatory cytokines in the stimulation of osteoclast activity. Endotoxin or bacterial challenges to inflammatory cells are directly relevant to dental implant pathologies involving bone resorption, such as osseointegration failure and peri-implantitis. While the endotoxin amount on implant devices is regulated by standards, it is unknown whether commercially available dental implants elicit different levels of adherent-endotoxin stimulated cytokines. The objective of this work is to develop a model system and evaluate endotoxin-induced expression of pro-inflammatory cytokine genes relevant to osteoclast activation on commercially available dental implants. Murine J774-A1 macrophages were cultured on Ti disks with different level of lipopolysaccharide (LPS) contamination to define the time-course of the inflammatory response to endotoxin, as evaluated by reverse transcription polymerase chain reaction analysis. The developed protocol was then used to measure adherent endotoxin on commercially available packaged and sterile dental implants in the "as-implanted" condition. Results show that tested dental implants induce variable expression of endotoxin-stimulated genes, sometimes above the level expected to promote bone resorption in vivo. Results are unaffected by the specific surface treatment; rather, they likely reflect care in cleaning and packaging protocols. In conclusion, expression of genes that enhance osteoclast activity through endotoxin stimulation of inflammatory cells is widely different on commercially available dental implants. A reappraisal of the clinical impact of adherent endotoxins on dental (and bone) implant devices is required in light of increasing knowledge on crosstalk between cells from the immune and skeletal systems.

  11. Soft tissue sealing around dental implants based on histological interpretation.

    PubMed

    Atsuta, Ikiru; Ayukawa, Yasunori; Kondo, Ryosuke; Oshiro, Wakana; Matsuura, Yuri; Furuhashi, Akihiro; Tsukiyama, Yoshihiro; Koyano, Kiyoshi

    2016-01-01

    The aim of this study was to provide an overview on the biology and soft tissue sealing around dental implants and teeth. This is a narrative review performed through scientific articles published between 1977 and 2014, indexed in MEDLINE and PubMed databases. The study selected articles that focused on epithelial sealing around dental implant or teeth with cell biology and histology of soft tissue. Implant therapy has been widely applied in dental rehabilitation for many years, with predictable long-term results. The longevity and functionality of dental implants is dependent on both osseointegration around the implant body and the establishment of a soft tissue barrier that protects the underlying hard tissue structures and the implant itself. The health and stability of the peri-implant mucosa also affects the esthetics of the implant. The healing and maintenance of the epithelial and connective tissues around implants are increasingly recognized as being fundamental to implant success. However, there has been little research into the function or formation of the soft tissue seal around dental implants, and the roles of this unique mucosal interface remain unclear. This narrative review explores the extent of the current knowledge of soft tissue barriers around implants from both a basic and clinical perspective, and aims to consolidate this knowledge and highlight the most pertinent questions relating to this area of research. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  12. Biofilm on dental implants: a review of the literature.

    PubMed

    Subramani, Karthikeyan; Jung, Ronald E; Molenberg, Aart; Hammerle, Christoph H F

    2009-01-01

    The aim of this article was to review the current literature with regard to biofilm formation on dental implants and the influence of surface characteristics (chemistry, surface free energy, and roughness) of dental implant and abutment materials and their design features on biofilm formation and its sequelae. An electronic MEDLINE literature search was conducted of studies published between 1966 and June 2007. The following search terms were used: biofilm and dental implants, biofilm formation/plaque bacterial adhesion and implants, plaque/biofilm and surface characteristics/roughness/surface free energy of titanium dental implants, implant-abutment interface and plaque/biofilm, biofilm and supragingival/subgingival plaque microbiology, biofilm/plaque and implant infection, antibacterial/bacteriostatic titanium, titanium nanocoating/nanopatterning, antimicrobial drug/titanium implant. Both in vitro and in vivo studies were included in this review. Fifty-three articles were identified in this review process. The articles were categorized with respect to their context on biofilm formation on teeth and dental implant surfaces and with regard to the influence of surface characteristics of implant biomaterials (especially titanium) and design features of implant and abutment components on biofilm formation. The current state of literature is more descriptive, rather than providing strong data that could be analyzed through meta-analysis. Basic research articles on surface modification of titanium were also included in the review to analyze the applications of such studies on the fabrication of implant surfaces that could possibly decrease early bacterial colonization and biofilm formation. Increase in surface roughness and surface free energy facilitates biofilm formation on dental implant and abutment surfaces, although this conclusion is derived from largely descriptive literature. Surface chemistry and the design features of the implant-abutment configuration also play a significant role in biofilm formation.

  13. The Prevalence of Dental Implants and Related Factors in Patients with Sjögren Syndrome: Results from a Cohort Study.

    PubMed

    Albrecht, Katinka; Callhoff, Johanna; Westhoff, Gisela; Dietrich, Thomas; Dörner, Thomas; Zink, Angela

    2016-07-01

    To investigate prevalence and patient-reported outcomes of dental implants in patients with Sjögren syndrome (SS). A total of 205 female patients from an observational cohort study answered oral health questionnaires about periodontal signs and symptoms, dentures, dental implants, comorbidities, and therapies that may interfere with bone remodeling. Data were compared with the reports of 87 female healthy controls. The patients were older than the controls (58 ± 12 and 54 ± 14 yrs, respectively) and differed substantially in the prevalence of self-reported gingivitis (60% and 35%), self-reported periodontitis (19% and 8%), and in the numbers of remaining teeth (21 ± 7 and 24 ± 5). Patients more frequently had removable prostheses (36% compared with 23%) and dental implants (16% compared with 7%). The 32 patients with SS with dental implants had a mean number of 3.1 ± 2.0 implants. Notably, for patients with implants, their oldest existing implant survived for a mean period of 4.9 ± 5.4 years. A total of 5 of 104 (4.8%) implants in the patients and none of the 14 implants in the controls had to be removed. A total of 75% of the patients were highly satisfied with the implants and 97% would recommend them to other patients with SS. A substantial portion of patients with SS have dental complications and require subsequent implants. The majority were satisfied with the implants and would recommend them to other patients. The high implant survival rate may encourage patients, rheumatologists, and dentists to consider dental implants for the treatment of patients with SS.

  14. Progress and trends in patients' mindset on dental implants. I: level of information, sources of information and need for patient information.

    PubMed

    Pommer, Bernhard; Zechner, Werner; Watzak, Georg; Ulm, Christian; Watzek, Georg; Tepper, Gabor

    2011-02-01

    Little is known about the level of information on implant dentistry in the public. A representative opinion poll on dental implants in the Austrian population was published in 2003 (Clinical Oral Implants Research 14:621-642). Seven years later, the poll was rerun to assess the up-to-date information level and evaluate recent progress and trends in patients' mindset on dental implants. One thousand adults--representative for the Austrian population--were presented with a total of 19 questionnaire items regarding the level and the sources of information about dental implants as well as the subjective and objective need for patient information. Compared with the survey of 2003, the subjective level of patient information about implant dentistry has significantly increased in the Austrian population. The patients' implant awareness rate was 79%. The objective level of general knowledge about dental implants was still all but satisfactory revealing unrealistic patient expectations. Three-quarters trusted their dentists for information about dental implants, while one-quarter turned to the media. The patients' wish for high-quality implant restorations was significantly higher than in 2003, yet the majority felt that only specialists should perform implant dentistry. This representative survey reveals that dentists are still the main source of patient information, but throws doubt on the quality of their public relations work. Dentists must improve communication strategies to provide their patients with comprehensible, legally tenable information on dental implants and bridge information gaps in the future. © 2010 John Wiley & Sons A/S.

  15. Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects

    PubMed Central

    Akay, Canan; Yaluğ, Suat

    2015-01-01

    Background The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). Material\\Methods A 3-dimensional finite element model of an Aramany class IV defect was created. Three different implant-retained obturator prostheses were modeled: model 1 with 1 zygomatic implant and 1 dental implant, model 2 with 1 zygomatic implant and 2 dental implants, and model 3 with 2 zygomatic implants. Locator attachments were used as a superstructure. A 150-N load was applied 3 different ways. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis are expressed in MPa. Results In all loading conditions, model 3 (when compared models 1 and 2) showed the lowest maximum principal stress value. Model 3 is the most appropirate reconstruction in Aramany class IV maxillary defects. Two zygomatic implants can reduce the stresses in model 3. The distribution of stresses on prostheses were more rational with the help of zygoma implants, which can distribute the stresses on each part of the maxilla. Conclusions Aramany class IV obturator prosthesis placement of 2 zygomatic implants in each side of the maxilla is more advantageous than placement of dental implants. In the non-defective side, increasing the number of dental implants is not as suitable as zygomatic implants. PMID:25714086

  16. Knowledge and attitude of elderly persons towards dental implants.

    PubMed

    Müller, Frauke; Salem, Kamel; Barbezat, Cindy; Herrmann, François R; Schimmel, Martin

    2012-06-01

    Despite their unrivalled place in restorative treatment, dental implants are still scarcely used in elderly patients. The aim of this survey was therefore to identify potential barriers for accepting an implant treatment. Participants were recruited from a geriatric hospital, two long-term-care facilities and a private clinic. The final study sample comprised 92 persons, 61 women and 31 men with an average age of 81.2 ± 8.0 years. In a semi-structured interview, the participants' knowledge of implants and attitude towards a hypothetical treatment with dental implants were evaluated. Twenty-seven participants had never heard of dental implants, and another 13 participants could not describe them. The strongest apprehensions against implants were cost, lack of perceived necessity and old age. Univariate and multiple linear regression analysis identified being women, type and quality of denture, having little knowledge on implants and being hospitalised as the risk factors for refusing implants. However, old age as such was not associated with a negative attitude. The acceptance of dental implants in the elderly population might be increased by providing further information and promoting oral health in general. Regardless of the age, dental implants should be placed when patients are still in good health and live independently. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  17. Decontamination methods using a dental water jet and dental floss for microthreaded implant fixtures in regenerative periimplantitis treatment.

    PubMed

    Park, Shin-Young; Kim, Kyoung-Hwa; Shin, Seung-Yun; Koo, Ki-Tae; Lee, Yong-Moo; Chung, Chong-Pyoung; Seol, Yang-Jo

    2015-06-01

    This study evaluated decontamination methods using a dental water jet and dental floss on microthreaded implants for regenerative periimplantitis therapy. In 6 beagle dogs, experimental periimplantitis was induced, and decontamination procedures, including manual saline irrigation (control group), saline irrigation using a dental water jet (group 1) and saline irrigation using a dental water jet with dental flossing (group 2), were performed. After in situ decontamination procedures, some of the implant fixtures (n = 4 per group) were retrieved for analysis by SEM, whereas other fixtures (n = 4 per group) underwent regenerative therapy. After 3 months of healing, the animals were killed. The SEM examination indicated that decontamination of the implant surfaces was the most effective in group 2, with no changes in implant surface morphology. The histological examination also revealed that group 2 achieved significantly greater amounts of newly formed bone (6.75 ± 2.19 mm; P = 0.018), reosseointegration (1.88 ± 1.79 mm; P = 0.038), and vertical bone fill (26.69 ± 18.42%; P = 0.039). Decontamination using a dental water jet and dental floss on microthreaded implants showed positive mechanical debridement effects and positive bone regeneration effects.

  18. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1983-07-15

    The upper two parts of the implant (post and core and crown) are conventional dental materials, usually gold. EX) 1473 MrION Of" I POV GS IS O&SOLETE...10 Clinical Examples of Baboon Dental Implants . . . . . . . . . . . 12 Histologic Analysis of the Bone-Implant Interface . . . . . . . . 16...Aluminum Oxide Dental Implant . . . . . . . . . . 2 Figure 2. Clinical Photograph of A29 and A30 in Baboon 469 at Necropsy

  19. Clinical effectiveness of International Team for Oral Implantology dental implant treatment in Taiwan: a seven-year longitudinal study.

    PubMed

    Tseng, Chuen-Chyi; Pang, Iok-Chao; Wen, Miin-Jye; Huang, Kuo-Ching; Chang, Jui-Chung

    2009-02-01

    International Team for Oral Implantology (ITI) dental implant has been clinically tested for the most parts of the world, especially in Europe and America, and has not been conducted on Asian population. The purpose of this study was to evaluate the cumulative survival and success rates over 7 years of ITI dental implants. The ITI dental implant system has been used in the Dental Department of Chi Mei Medical Center since August of 1997. At the end of 2005, 717 solid-screw implants had been placed and loaded at least 6 months in 316 patients. The patient population included 145 males and 171 females, with a mean age of 43.18 +/- 11.60 years. The follow-up interval was from 6 months after the prosthesis was completed to 7 years. The success criteria of dental implant survival was based on Buser et al, Clin Oral Implants Res. 1990;1:33-40. Most implants (486, 67.8%) were placed in the mandible and 231 (32.2%) were placed in the maxilla. Two implants were removed before prostheses fabrication because of postsurgical infections. One implant was removed due to a periapical infection of an adjacent natural tooth. The life table analysis of survival rate and success rate were 99.58% and 96.13%, respectively. This 7-year clinical effectiveness study demonstrated this dental implant system gave a clinical reliable result in a Taiwanese population.

  20. The Key Points of Maintenance Therapy for Dental Implants: A Literature Review.

    PubMed

    Pirc, Miha; Dragan, Irina F

    2017-04-01

    Dental implants require lifelong maintenance and care. Success is defined by biologic factors (presence of inflamed soft tissues surrounding dental implants and radiographic changes in the crestal bone levels) and mechanical factors (stability of the implant fixture and implant supported restoration, etc). Most implant failures are initiated by incipient stages of inflammatory processes, which lead to peri-mucositis and peri-implantitis. The evidence regarding the value of maintenance protocol regarding implants is sparse compared with the one for teeth. This article addresses the existing literature on processes for oral hygiene for implant care.

  1. The psychosocial impacts of implantation on the dental aesthetics of missing anterior teeth patients.

    PubMed

    Chen, P; Yu, S; Zhu, G

    2012-12-01

    The aim of the current study was to investigate the psychosocial impact of dental aesthetics among patients who received anterior implant-supported prostheses. The current study is a cross-sectional evaluation involving 115 individuals who had gone through treatment at the dental clinics of general hospitals. Participants completed the Chinese version of the psychosocial impact of dental aesthetics questionnaire (PIDAQ) before implantation and six months after crown restoration. Basic demographic information was recorded. Six months after implant crown restoration, participants were asked to self-assess their own oral aesthetics compared to before implantation. A total of 106 patients completed the study. PIDAQ scores correlated significantly with the self-assessment of the degree of oral aesthetics. Six months after crown restoration, the two factors (social impact and aesthetic attitude) decreased and the dental self-confidence score increased significantly compared to pre-implantation scores. Gender and education level significantly affected PIDAQ. Anterior implant-supported prostheses significantly affected the patients' psychosocial perception. Implantation of missing anterior teeth can significantly improve patients' negative psychosocial impact of dental aesthetics. Gender and education level are correlated with the degree of improvement. The PIDAQ can be used in assessing the psychosocial effects of implantation in missing anterior teeth.

  2. A retrospective study on related factors affecting the survival rate of dental implants

    PubMed Central

    Kang, Jeong-Kyung; Lee, Ki; Lee, Yong-Sang; Park, Pil-Kyoo

    2011-01-01

    PURPOSE The aim of this retrospective study is to analyze the relationship between local factors and survival rate of dental implant which had been installed and restored in Seoul Veterans Hospital dental center for past 10 years. And when the relationship is found out, it could be helpful to predict the prognosis of dental implants. MATERIALS AND METHODS A retrospective study of patients receiving root-shaped screw-type dental implants placed from January 2000 to December 2009 was conducted. 6385 implants were placed in 3755 patients. The following data were collected from the dental records and radiographs: patient's age, gender, implant type and surface, length, diameter, location of implant placement, bone quality, prosthesis type. The correlations between these data and survival rate were analyzed. Statistical analysis was performed with the use of Kaplan-Meier analysis, Chi-square test and odds ratio. RESULTS In all, 6385 implants were placed in 3755 patients (3120 male, 635 female; mean age 65 ± 10.58 years). 108 implants failed and the cumulative survival rate was 96.33%. There were significant differences in age, implant type and surface, length, location and prosthesis type (P<.05). No significant differences were found in relation to the following factors: gender, diameter and bone quality (P>.05). CONCLUSION Related factors such as age, implant type, length, location and prosthesis type had a significant effect on the implant survival. PMID:22259704

  3. Viability of dental implants in head and neck irradiated patients: A systematic review.

    PubMed

    Zen Filho, Edson Virgílio; Tolentino, Elen de Souza; Santos, Paulo Sérgio Silva

    2016-04-01

    The purpose of this systematic review was to evaluate the safety of dental implants placed in irradiated bone and to discuss their viability when placed post-radiotherapy (RT). A systematic review was performed to answer the questions: "Are dental implants in irradiated bone viable?" and "What are the main factors that influence the loss of implants in irradiated patients?" The search strategy resulted in 8 publications. A total of 331 patients received 1237 implants, with an overall failure rate of 9.53%. The osseointegration success rates ranged between 62.5% and 100%. The optimal time interval between irradiation and dental implantation varied from 6 to 15 months. The interval time between RT and implant placement and the radiation doses are not associated with significant implant failure rates. The placement of implants in irradiated bone is viable, and head and neck RT should not be considered as a contraindication for dental rehabilitation with implants. © 2015 Wiley Periodicals, Inc. Head Neck 38: E2229-E2240, 2016. © 2015 Wiley Periodicals, Inc.

  4. Exotic encounters with dental implants: managing complications with unidentified systems.

    PubMed

    Mattheos, N; Janda, M Schittek

    2012-06-01

    As the application of dental implants increases worldwide, so is the number of technical and biological complications that general dental practitioners will be called to manage, while maintaining implant patients. In addition, the greater patient mobility encountered today combined with a growing trend of 'dental implant tourism' will very often result in situations where the dentist is requested to deal with complications in implants placed elsewhere and which sometimes might be of an 'exotic' system one cannot directly recognize. Such a situation can pose significant challenges to even experienced clinicians. The challenges are not only in the scientific field, but often include professional and ethical implications. This case report will discuss strategies for the management of implant complications in cases of unidentified implant systems. Critical factors in such situations would be the clinician's experience and special training, the correct radiographic technique, as well as access to the appropriate tools and devices. © 2012 Australian Dental Association.

  5. Facilitators and barriers influencing the readiness to receive dental implants in a geriatric institutionalised population-A randomized non-invasive interventional study.

    PubMed

    Merz, Miriam A; Terheyden, Hendrik; Huber, Christian G; Seixas, Azizi A; Schoetzau, Andreas; Schneeberger, Andres R

    2017-09-01

    Although elderly people have many serious dental issues and are in need of prosthesis, few opt for dental implants. The aim of this study was to investigate barriers that prevent elderly people from receiving dental implants. Specifically, we examined (i) whether the message was delivered before or after the interview had an impact, and (ii) whether it did matter who delivered the message. Sixty-six residents from seven residential homes in the Canton of Grisons, Switzerland were included. The sample was randomized to a treatment group that received comprehensive education about dental implants before the interview and a control group that received education after completing the questionnaire. The sample consisted of 54 women (81.8%) and 12 males (18.2%) with an average age of 86.2 years. Education before the interview did not show any impact on the attitude towards dental implants. Main reasons for a negative attitude towards implants were old age and high costs. Participants who received information about implants from their relatives and their own dentist and not from the study dentist were significantly more willing to receive implants. Providing an adequate education about benefits and risks of receiving dental implants does not change the attitude towards dental implants. The source of information/messenger does influence attitudes towards implants. If the person delivering the education and information is a relative or a known medical person, the person's attitude is more likely to change as compared to people receiving the information from an unrelated person. © 2017 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  6. Expansion of a Predoctoral Surgical Implant Selective for Dental Students.

    PubMed

    Seitz, Stefanie D; Zimmermann, Richard L; Hendricson, William D

    2016-03-01

    Historically, predoctoral dental education programs have focused on the restoration of implants in the clinical environment; however, given the increase in dental implant therapy being performed by general dentists, the need to incorporate surgical implant training is becoming evident. This article describes a predoctoral surgical implant selective at the University of Texas Health Science Center at San Antonio and its evolution across five years to include emerging techniques and technology to enhance students' understanding of dental implant therapy, both surgical and restorative. From virtual implant planning and guided surgery to intra-oral scanning of implants for custom abutments and restorations, students obtained first-hand experiences with a wide spectrum of aspects of implant therapy. The results of anonymous surveys completed by 2014-15 students before and after the year-long selective regarding their impression of the program are also discussed.

  7. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1985-11-15

    project in the development of dental implantology must not be overlooked. The early stages of this project clearly defined that rigid fixation of an...a long-term implant study of a serrated ceramic dental implant designed for fresh extraction sites. The baboon study was successfully completed last...materials. A series of graded dental implants have been produce’ to provide an interference fit in any fresh extraction site. The long-term implant

  8. Oral Rehabilitation with Implant-Retained Overdenture in a Patient with Down Syndrome.

    PubMed

    Altintas, Nuray Yilmaz; Kilic, Serdar; Altintas, Subutay Han

    2017-01-24

    Down syndrome, known as trisomy 21, is the most common chromosomal disorder. The disorder affects mental and systemic development as well as oral structure, including dental anomalies, high susceptibility of periodontal disease, and poor quality of alveolar bone. This report presents a case of dental rehabilitation by means of dental implants of a patient with Down syndrome. Two titanium dental implants were placed in the maxilla, and three titanium dental implants were installed in the mandible. One implant was lost during the osseointegration period. The prosthetic rehabilitation was performed with implant-retained maxillary and mandibular overdentures with the Locator attachment system. After a 2-year follow-up period, the patient was doing well, and all implants were clinically stable with no signs of bone loss or inflammation. The present study emphasizes that implant-retained overdentures with Locator attachment system could be a therapeutic option even for patients with Down syndrome. This therapy prevents crestal bone loss around the implants, improves functional and esthetic outcomes, and provides optimum oral hygiene for patients with mild mental impairment. Careful patient selection and education of patients and caregivers are essential considerations for a successful and safe treatment with dental implants in Down syndrome patients. © 2017 by the American College of Prosthodontists.

  9. A novel dental implant abutment with micro-motion capability--development and biomechanical evaluations.

    PubMed

    Chen, Yen-Yin; Chen, Weng-Pin; Chang, Hao-Hueng; Huang, Shih-Hao; Lin, Chun-Pin

    2014-02-01

    The aim of this study was to develop a novel dental implant abutment with a micro-motion mechanism that imitates the biomechanical behavior of the periodontal ligament, with the goal of increasing the long-term survival rate of dental implants. Computer-aided design software was used to design a novel dental implant abutment with an internal resilient component with a micro-motion capability. The feasibility of the novel system was investigated via finite element analysis. Then, a prototype of the novel dental implant abutment was fabricated, and the mechanical behavior was evaluated. The results of the mechanical tests and finite element analysis confirmed that the novel dental implant abutment possessed the anticipated micro-motion capability. Furthermore, the nonlinear force-displacement behavior apparent in this micro-motion mechanism imitated the movement of a human tooth. The slope of the force-displacement curve of the novel abutment was approximately 38.5 N/mm before the 0.02-mm displacement and approximately 430 N/mm after the 0.03-mm displacement. The novel dental implant abutment with a micro-motion mechanism actually imitated the biomechanical behavior of a natural tooth and provided resilient function, sealing, a non-separation mechanism, and ease-of-use. Copyright © 2013 Academy of Dental Materials. All rights reserved.

  10. Dental implants typically help retain peri-implant vertical bone height: evidence-based analysis.

    PubMed

    Greenstein, Gary; Cavallaro, John

    2013-01-01

    The dental literature is assessed regarding the ability of dental implants to maintain vertical bone height after various implant placement scenarios: immediate, delayed, insertion into partially and fully edentate healed ridges, and under overdentures. Studies are also reviewed to determine if bone loss after implant insertion is continuous. Numerous investigations that support the concept that implants preserve bone height are identified. In addition, the data indicate that a minuscule amount of annual bone loss usually persists after implant placement, but it is often clinically imperceptible.

  11. Unified Approach to the Biomechanics of Dental Implantology

    NASA Technical Reports Server (NTRS)

    Grenoble, D. E.; Knoell, A. C.

    1973-01-01

    The human need for safe and effective dental implants is well-recognized. Although many implant designs have been tested and are in use today, a large number have resulted in clinical failure. These failures appear to be due to biomechanical effects, as well as biocompatibility and surgical factors. A unified approach is proposed using multidisciplinary systems technology, for the study of the biomechanical interactions between dental implants and host tissues. The approach progresses from biomechanical modeling and analysis, supported by experimental investigations, through implant design development, clinical verification, and education of the dental practitioner. The result of the biomechanical modeling, analysis, and experimental phases would be the development of scientific design criteria for implants. Implant designs meeting these criteria would be generated, fabricated, and tested in animals. After design acceptance, these implants would be tested in humans, using efficient and safe surgical and restorative procedures. Finally, educational media and instructional courses would be developed for training dental practitioners in the use of the resulting implants.

  12. Why do dental implants fail? Part I.

    PubMed

    el Askary, A S; Meffert, R M; Griffin, T

    1999-01-01

    Many factors are attributed to failure of the dental implant, either directly or indirectly. The focus of this article is to define the causation of dental implant failure, as well as to present an evaluation of the implant literature regarding etiology, classification, management, and treatment of implant failures. This article will highlight the initial signs of implant failure with a view of some clinical cases in terms of classification and degrees of implant failure. Finally, a dental implant failure checklist is formulated to guide the practitioner in defining the cause of implant failure, be it infective or noninfective, and to establish percentages and frequency of occurrence. The checklist applies to all implant systems and will help to determine the factors responsible for causation and the repair procedures, whether they are at the surgical or restorative phases. The definition of implant failure is set forth in terms of ailing, failing, failed, and surviving implants, and the appropriate treatments and dispositions are outlined.

  13. Optimization of dental implantation

    NASA Astrophysics Data System (ADS)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  14. Air Abrasive Disinfection of Implant Surfaces in a Simulated Model of Peri-Implantitis

    DTIC Science & Technology

    2016-06-01

    A thesis submitted to the Faculty of the Periodontics Graduate Program Naval Postgraduate Dental School Uniformed Services University of the...Department, 2016 Thesis directed by: Glen M. Imamura, DDS, MS Chairman, Dental Research Department Naval Postgraduate Dental School...Introduction: Dental implant technology has evolved into a predictable treatment option for the restoration of edentulous sites. However, peri

  15. Application of uniform design to improve dental implant system.

    PubMed

    Cheng, Yung-Chang; Lin, Deng-Huei; Jiang, Cho-Pei

    2015-01-01

    This paper introduces the application of uniform experimental design to improve dental implant systems subjected to dynamic loads. The dynamic micromotion of the Zimmer dental implant system is calculated and illustrated by explicit dynamic finite element analysis. Endogenous and exogenous factors influence the success rate of dental implant systems. Endogenous factors include: bone density, cortical bone thickness and osseointegration. Exogenous factors include: thread pitch, thread depth, diameter of implant neck and body size. A dental implant system with a crest module was selected to simulate micromotion distribution and stress behavior under dynamic loads using conventional and proposed methods. Finally, the design which caused minimum micromotion was chosen as the optimal design model. The micromotion of the improved model is 36.42 μm, with an improvement is 15.34% as compared to the original model.

  16. Non-Destructive Analysis of Basic Surface Characteristics of Titanium Dental Implants Made by Miniature Machining

    NASA Astrophysics Data System (ADS)

    Babík, Ondrej; Czán, Andrej; Holubják, Jozef; Kameník, Roman; Pilc, Jozef

    2016-12-01

    One of the most best-known characteristic and important requirement of dental implant is made of biomaterials ability to create correct interaction between implant and human body. The most implemented material in manufacturing of dental implants is titanium of different grades of pureness. Since most of the implant surface is in direct contact with bone tissue, shape and integrity of said surface has great influence on the successful osseointegration. Among other characteristics of titanium that predetermine ideal biomaterial, it shows a high mechanical strength making precise machining miniature Increasingly difficult. The article is focused on evaluation of the resulting quality, integrity and characteristics of dental implants surface after machining.

  17. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1982-07-15

    design. The serrated root portion is alumina ceramic. The upper two parts of the implant (post and core and crown) are conventional dental materials...ceramic. The upper two parts of the implant (post and core and crown) are conventional dental materials, usually gold. Roots are produced by grinding...I1 Clinical Examples of Baboon Dental Implants . . . .. . . . .. 12 Clinical Chemistry and Hematology Results in Baboons. . . . . . . 20

  18. Management of Broken Dental Implant Abutment in a Patient with Bruxism: A Rare Case Report and Review of Literature.

    PubMed

    Al-Almaie, Saad

    2017-01-01

    This rare case report describes prosthodontic complications resulting from a dental implant was placed surgically more distally in the area of the missing mandibular first molar with a cantilever effect and a crest width of >12 mm in a 59-year-old patient who had a history of bruxism. Fracture of abutment is a common complication in implant was placed in area with high occlusal forces. Inability to remove the broken abutment may most often end up in discarding the implant. Adding one more dental implant mesially to the previously placed implant, improvisation of technique to remove the broken abutment without sacrificing the osseointegrated dental implant, fabrication with cemented custom-made abutment to replace the broken abutment for the first implant, and the use of the two implants to replace a single molar restoration proved reliable and logical treatment solutions to avoid these prosthodontic complications.

  19. Dental Implants in an Aged Population: Evaluation of Periodontal Health, Bone Loss, Implant Survival, and Quality of Life.

    PubMed

    Becker, William; Hujoel, Philippe; Becker, Burton E; Wohrle, Peter

    2016-06-01

    To evaluate aged partially and fully edentulous patients who received dental implants and were maintained over time. Further, to determine how the partially and edentulous ageing populations (65 and above) with dental implants maintain bone levels, proper oral hygiene, and perceive benefits of dental implants. Since 1995, patients receiving dental implants have been prospectively entered into an Access-based computerized program (Triton Tacking System). Patient demographics (age, sex), bone quality, quantity, implant location, and type of surgery have been continuously entered into the database. The database was queried for patients receiving implants (first stage) between 66 and 93 years of age. Thirty-one patients were within this age group. Twenty-five patients returned to the clinic for periodontal and dental implant evaluation. The Periodontal Index was used to evaluate selected teeth in terms of probing depth, bleeding on probing, plaque accumulation, and mobility. Using NIH Image J, radiographs taken at second stage and last examination were measured for changes in interproximal bone levels. Once identified, each patient anomalously filled out an abbreviated quality of health life form. Due to small sample size, descriptive statistics were used to compare clinical findings. Fifteen males ranging from 78 to 84 (mean age 84 years) years and 16 females from 66 to 93 (mean age 83 years) (age range 66-93) were contacted by phone or mail and asked to return to our office for a re-examination. For this group, the first dental implants were placed in 1996 (n = initial two implants) and continuously recorded through 2013 (n = last seven implants). Thirty-one patients received a total of 84 implants. Two patients were edentulous, and the remaining were partially edentulous. Four implants were lost. Between implant placement and 6- to 7-year interval, 13 patients with 40 implants had a cumulative survival rate of 94.6%. Of the original group (n = 33), three were deceased, two were in nursing homes, and three could not be located. Aged patients receiving dental implants had excellent implant survival rates, low periodontal disease index scores with minimal changes in interproximal bone levels. Results from this study indicate that patients with advanced age, in reasonably good health, have excellent implant survival rates, excellent quality of life scores, and can be maintained in good oral health. © 2015 Wiley Periodicals, Inc.

  20. Dental Implants in the Elderly Population: A Long-Term Follow-up.

    PubMed

    Compton, Sharon M; Clark, Danielle; Chan, Stephanie; Kuc, Iris; Wubie, Berhanu A; Levin, Liran

    The objectives of this study were to evaluate implant survival and success in the elderly population and to assess indicators and risk factors for success or failure of dental implants in older adults (aged 60 years and older). This historical prospective study was developed from a cohort of patients born prior to 1950 who received dental implants in a single private dental office. Implant survival and marginal bone levels were recorded and analyzed with regard to different patient- and implant-related factors. The study examined 245 patient charts and 1,256 implants from one dental clinic. The mean age at the time of implant placement was 62.18 ± 8.6 years. Smoking was reported by 9.4% of the cohort studied. The overall survival rate of the implants was 92.9%; 7.1% of the implants had failed. Marginal bone loss depicted by exposed threads was evident in 23.3% of the implants. Presenting with generalized periodontal disease and/or severe periodontal disease negatively influenced the survival probability of the implant. Implants placed in areas where bone augmentation was performed prior to or during implant surgery did not have the same longevity compared with those that did not have augmentation prior to implantation. The overall findings concluded that implants can be successfully placed in older adults. A variety of factors are involved in the long-term success of the implant, and special consideration should be taken prior to placing implants in older adults to limit the influence of those risk factors.

  1. Awareness, knowledge, and attitude of patients toward dental implants - A questionnaire-based prospective study.

    PubMed

    Hosadurga, Rajesh; Shanti, Tenneti; Hegde, Shashikanth; Kashyap, Rajesh Shankar; Arunkumar, Suryanarayan Maiya

    2017-01-01

    In developing nations like India awareness and education about dental implants as a treatment modality is still scanty. The study was conducted to determine the awareness, knowledge, and attitude of patients toward dental implants as a treatment modality among the general population and to assess the influence of personality characteristics on accepting dental implants as a treatment modality in general and as well as treatment group. A structured questionnaire-based survey was conducted on 500 randomly selected participants attending the outpatient department. The study was conducted in 2 parts. In the first part of the study, level of awareness, knowledge, and attitude was assessed. In the second part of the study, interactive educational sessions using audiovisual aids were conducted following which a retest was conducted. The participants who agreed to undergo implant treatment were followed up to assess their change in attitude towards dental implants posttreatment. Thus pain, anxiety, functional, and esthetic benefits were measured using visual analog scale. They were further followed up for 1 year to reassess awareness, knowledge, and attitude towards dental implants. A total of 450 individuals completed the questionnaires. Only 106 individuals agreed to participate in the educational sessions and 83 individuals took the retest. Out of these, only 39 individuals chose implants as a treatment option. A significant improvement in the level of information, subjective and objective need for information, was noted after 1 year. In this study, a severe deficit in level of information, subjective and objective need for information towards, dental implants as a treatment modality was noted. In the treatment group, a significant improvement in perception of dental implant as a treatment modality suggests that professionally imparted knowledge can bring about a change in the attitude.

  2. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series

    PubMed Central

    Gay-Escoda, Cosme; Pérez-Álvarez, Débora; Camps-Font, Octavi

    2016-01-01

    Background The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Results Nine participants (57 implants) were included. The patients’ median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Conclusions Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented. Key words:HIV infection, dental implants, oral implantology, complications, peri-implantitis, peri-implant diseases. PMID:26946205

  3. Oral rehabilitation with dental implants and quality of life following mandibular reconstruction with free fibular flap.

    PubMed

    Jacobsen, Hans-Christian; Wahnschaff, Falko; Trenkle, Thomas; Sieg, Peter; Hakim, Samer G

    2016-01-01

    Bony reconstruction of jaw defects using the free fibular flap and dental rehabilitation mostly requires insertion of dental implants within the transferred fibula bone. The aim of this paper was to discuss results of the implant stability with data on the possible benefit for the patient's quality of life after such treatment. For clinical outcome of implants, we evaluated 26 patients with a total number of 94 dental implants after a follow-up period of 12 to 132 months. A group of 38 patients who underwent mandibular reconstruction with free fibular flap could be included in the life-quality study. Evaluation included 23 patients with and 15 patients without implant-borne restoration. The quality of life was assessed using the standard QLQ C-30 questionnaire and the H&N35 module of the European Organisation for Research and Treatment of Cancer (EORTC). Of implants, 94.7 % were stable at the time of investigation and could be used for prosthesis. Patients with dental implants reported improvement of life quality along with better scores in most function and symptom scales; however, only values for global health status (QL2), absence of dyspnea (DY) and absence of feeding tube (HNFE) were significantly better than in the control group. Dental implant insertion in fibula grafts along with implant-borne restoration is a proven concept and might lead to improved quality of life following ablative surgery of the jaw. The effect on the quality of life is not as predictable as on the implant stability. Patients with bony defects of the jaw require bony reconstruction. This allows further masticatory rehabilitation using dental implants and might lead to improved quality of life.

  4. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

    PubMed Central

    2011-01-01

    Purpose This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). Materials and Methods This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. Results The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. Conclusion CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement. PMID:21977476

  5. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement.

    PubMed

    Yunus, Barunawaty

    2011-06-01

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  6. Use of Metallic Endosseous Implants as a Tooth Substitute.

    DTIC Science & Technology

    1979-06-01

    exposed in the oral cavity and placed in function with the opposing dentition iBACKGROUND The development of a dental implant that will serve as a...contract year was spent in testing the dental implant as a single tooth replacement. The ultimate goal of this implant study was to develop a free-standing...to read and sign an informed consent form. SURGICAL PROCEDURES The dental implant was inserted into the edentulous area using the exact procedures as

  7. Damping Factor as a Diagnostic Parameter for Assessment of Osseointegration during the Dental Implant Healing Process: An Experimental Study in Rabbits.

    PubMed

    Feng, Sheng-Wei; Ho, Kuo-Ning; Chan, Ya-Hui; Chang, Kai-Jung; Lai, Wei-Yi; Huang, Haw-Ming

    2016-12-01

    The purpose of this study was to evaluate the possibility of using damping factor (DF) analysis to provide additional information on osseointegration of dental implants during the healing period. A total of 30 dental implants were installed in the bilateral femoral condyles of 15 rabbits. A DF analyzer detected with an impulse-forced vibration method and a commercialized dental implant stability analyzer based on resonance frequency (RF) analysis were used to measure the implant stability immediately after implant placement and 1, 2, 4, and 8 weeks post-surgically. Results of DF and RF analyses at different time points were compared with the corresponding osseointegration performance of dental implants via micro-computed tomography (micro-CT), histological and histomorphometrical analysis. The DF values revealed a decrease with time and reached 0.062 ± 0.007 at 8 weeks after implantation, which is almost 50% lower than the initial value. Moreover, highly significant correlations between DF values and bone volume densities (R 2  = 0.9797) and percentages of bone-to-implant contact measured at trabecular bone area (R 2  = 0.9773) were also observed. These results suggested that DF analysis combined with RF analysis results in a more sensitive assessment of changes in the dental implant/bone complex during the healing period than RF analysis alone.

  8. The impact of glucocorticosteroids administered for systemic diseases on the osseointegration and survival of dental implants placed without bone grafting-A retrospective study in 31 patients.

    PubMed

    Petsinis, Vassilis; Kamperos, Georgios; Alexandridi, Foteini; Alexandridis, Konstantinos

    2017-08-01

    To evaluate the impact of glucocorticosteroids, administered for the treatment of systemic diseases, on the osseointegration and survival of dental implants placed without bone grafting. A retrospective study was conducted in search of patients treated with dental implants while receiving glucocorticosteroid therapy for various systemic diseases. In these cases, a conventional two-stage surgical protocol was used, without bone regeneration procedures. The osseointegration was clinically and radiographically tested at the uncovering of the implants. The follow-up after loading was set at a minimum of 3 years. A total of 31 patients were included in the study. Of the 105 dental implants placed, 104 were osseointegrated (99%). No bone absorption was radiographically noted at the uncovering of the osseointegrated implants. All of the osseointegrated implants were successfully loaded for the prosthetic restoration. The mean follow-up period after loading was 71 months, with an implant survival rate of 99%. Glucocorticosteroid intake for systemic diseases does not have a significant impact on the osseointegration and the 3-year survival of dental implants placed with a conventional two-stage surgical protocol and without bone grafting. Therefore, it should not be considered a contraindication for dental implant placement. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Osseoperception in Dental Implants: A Systematic Review.

    PubMed

    Mishra, Sunil Kumar; Chowdhary, Ramesh; Chrcanovic, Bruno Ramos; Brånemark, Per-Ingvar

    2016-04-01

    Replacement of lost teeth has significant functional and psychosocial effects. The capability of osseointegrated dental implants to transmit a certain amount of sensibility is still unclear. The phenomenon of developing a certain amount of tactile sensibility through osseointegrated dental implants is called osseoperception. The aim of this article is to evaluate the available literature to find osseoperception associated with dental implants. To identify suitable literature, an electronic search was performed using Medline and PubMed database. Articles published in English and articles whose abstract is available in English were included. The articles included in the review were based on osseoperception, tactile sensation, and neurophysiological mechanoreceptors in relation to dental implants. Articles on peri-implantitis and infection-related sensitivity were not included. Review articles without the original data were excluded, although references to potentially pertinent articles were noted for further follow-up. The phenomenon of osseoperception remains a matter of debate, so the search strategy mainly focused on articles on osseoperception and tactile sensibility of dental implants. This review presents the histological, neurophysiological, and psychophysical evidence of osseoperception and also the role of mechanoreceptors in osseoperception. The literature on osseoperception in dental implants is very scarce. The initial literature search resulted in 90 articles, of which 81 articles that fulfilled the inclusion criteria were included in this systematic review. Patients restored with implant-supported prostheses reported improved tactile and motor function when compared with patients wearing complete dentures. © 2016 by the American College of Prosthodontists.

  10. The role of angiogenesis in implant dentistry part I: Review of titanium alloys, surface characteristics and treatments.

    PubMed

    Saghiri, M-A; Asatourian, A; Garcia-Godoy, F; Sheibani, N

    2016-07-01

    Angiogenesis plays an important role in osseointegration process by contributing to inflammatory and regenerative phases of surrounding alveolar bone. The present review evaluated the effect of titanium alloys and their surface characteristics including: surface topography (macro, micro, and nano), surface wettability/energy, surface hydrophilicity or hydrophobicity, surface charge, and surface treatments of dental implants on angiogenesis events, which occur during osseointegration period. An electronic search was performed in PubMed, MEDLINE, and EMBASE databases via OVID using the keywords mentioned in the PubMed and MeSH headings regarding the role of angiogenesis in implant dentistry from January 2000-April 2014. Of the 2,691 articles identified in our initial search results, only 30 met the inclusion criteria set for this review. The hydrophilicity and topography of dental implants are the most important and effective surface characteristics in angiogenesis and osteogenesis processes. The surface treatments or modifications of dental implants are mainly directed through the enhancement of biological activity and functionalization in order to promote osteogenesis and angiogenesis, and accelerate the osseointegration procedure. Angiogenesis is of great importance in implant dentistry in a manner that most of the surface characteristics and treatments of dental implants are directed toward creating a more pro-angiogenic surface on dental implants. A number of studies discussed the effect of titanium alloys, dental implant surface characteristic and treatments on agiogenesis process. However, clinical trials and in-vivo studies delineating the mechanisms of dental implants, and their surface characteristics or treatments, action in angiogenesis processes are lagging.

  11. Attitudes of general dental practitioners towards implant dentistry in an environment with widespread provision of implant therapy.

    PubMed

    Lang-Hua, Bich Hue; Lang, Niklaus P; Lo, Edward C M; McGrath, Colman P J

    2013-03-01

    To determine attitudes of general dental practitioners in a community where provision dental implants is a well-known treatment modality; and to identify variations in the attitudes with respect to dentists' factors, training factors and implant provision factors. A questionnaire survey to a random sample of registered dentists In Hong Kong was performed. Attitudes towards implant dentistry with respect to (i) perceived superiority of implant therapy, (ii) perceived outcomes of dental implant therapy, (iii) perceived complications & maintenance issues and (iv) placement issues were ascertained. In addition, information was collected on dentists' factors, training factors and implant provision factors. Variations in attitudes towards implant dentistry were explored in bivariate and regression analyses. Among eligible practitioners (n = 246), the response rate was 46.3%. Dentists perceived implants to be superior to conventional prostheses for the replacement of a single missing posterior tooth (80%, 67) and likewise, for the replacement of a single missing anterior tooth (67%, 67), P < 0.05. Variations in attitudes with respect to attitudes exists with respect to dentists' factors (years in practice [P < 0.05]), place of graduation (P < 0.05); implant trainings factors ("hand-on" training [P < 0.05]); number of days of training (P < 0.05) and implant experience factors (Number of patients treated [P < 0.05]) and number of implants placed (P < 0.05). In a community where provision of dental implants is widespread among its General Dental Practitioners (GDPs), their attitudes are not wholly in line with evidence-based knowledge. Variations in their attitudes existed with respect to dentist factors, training and experience issues. © 2012 John Wiley & Sons A/S.

  12. Survival of Dental Implants Placed in Grafted and Nongrafted Bone: A Retrospective Study in a University Setting.

    PubMed

    Tran, Duong T; Gay, Isabel C; Diaz-Rodriguez, Janice; Parthasarathy, Kavitha; Weltman, Robin; Friedman, Lawrence

    2016-01-01

    To compare dental implant survival rates when placed in native bone and grafted sites. Additionally, risk factors associated with dental implant loss were identified. This study was based on the hypothesis that bone grafting has no effect on implant survival rates. A retrospective chart review was conducted for patients receiving dental implants at the University of Texas, School of Dentistry from 1985 to 2012. Exclusion criteria included patients with genetic diseases, radiation and chemotherapy, or an age less than 18 years. To avoid misclassification bias, implants were excluded if bone grafts were only done at the same time of placement. Data on age, sex, tobacco use, diabetes, osteoporosis, anatomical location of the implant, implant length and width, bone graft, and professional maintenance were collected for analysis. A total of 1,222 patients with 2,729 implants were included. The cumulative survival rates at 5 and 10 years were 92% and 87% for implants placed in native bone and 90% and 79% for implants placed in grafted bone, respectively. The results from multivariate analysis (Cox regression) indicated no significant difference in survival between the two groups; having maintenance therapy after implant placement reduced the failure rate by 80% (P < .001), and using tobacco increased the failure rate by 2.6-fold (P = .001). There was no difference in the dental implant survival rate when implants were placed in native bone or bone-grafted sites. Smoking and lack of professional maintenance were significantly related to increased implant loss.

  13. Long-term success of dental implants in patients with head and neck cancer after radiation therapy.

    PubMed

    Curi, M M; Condezo, A F B; Ribeiro, K D C B; Cardoso, C L

    2018-06-01

    The purpose of this study was to analyze the long-term success and factors potentially influencing the success of dental implants placed in patients with head and neck cancer who underwent radiation therapy with a minimum total dose of 50Gy during the years 1995-2010. Thirty-five patients (169 dental implants) were included in this study. Data on demographic characteristics, tumour type, radiation therapy, implant sites, implant dimensions, and hyperbaric oxygen therapy (HBOT) were obtained from the medical records and analyzed. Implant survival was estimated using Kaplan-Meier survival curves. Seventy-nine dental implants were placed in the maxilla and 90 in the mandible. The mean follow-up after implant installation was 7.4 years (range 0.3-14.7 years). The overall 5-year survival rate for all implants was 92.9%. Sex (P<0.001) and the mode of radiation therapy delivery (P=0.005) had a statistically significant influence on implant survival. Age, time of implantation after irradiation, implant brand and dimensions, and HBOT had no statistically significant influence on implant survival. Osseointegrated dental implants can be used successfully in the oral rehabilitation of patients with head and neck cancer with a history of radiation therapy. Risk factors such as sex and the mode of radiation therapy delivery can affect implant survival. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Peri-Implant Tissue Findings in Bone Grafted Oral Cancer Patients Compared to non Bone Grafted Patients without Oral Cancer

    PubMed Central

    Agata, Hideki; Sándor, George K.; Haimi, Suvi

    2011-01-01

    ABSTRACT Objectives The aim of this study was to compare microbiological, histological, and mechanical findings from tissues around osseointergrated dental implants in patients who had undergone tumour resection and subsequent bone grafting with non bone grafted patients without a history of oral cancer and to develop an effective tool for the monitoring of the peri-implant tissues. A third aim was to assess and compare the masticatory function of the two patient groups after reconstruction with dental implants. Material and Methods A total of 20 patients were divided into 2 groups. The first group was edentulous and treated with dental implants without the need for bone grafting. The second edentulous group, with a history of oral cancer involving the mandible, received onlay bone grafts with concurrent placement of dental implants. Microbiological, histological, mechanical and biochemical assessment methods, crevicular fluid flow rate, hygiene-index, implant mobility, and the masticatory function were analysed and compared in both patient groups. Results The microbiological examinations showed no evidence of the three most common pathogenic bacteria: Porphyromonas gingivalis, Prevotella intermedius, Actinobacillus actinomycetencomitans. A causal relationship between specific microbes and peri-implant inflammation could not be found. All biopsies in both patient groups revealed early signs of soft tissue peri-implant inflammation. Conclusions The crevicular fluid volume and grade of gingival inflammation around the dental implants were related. Peri-implant tissue findings were similar in the two patient groups despite the history of oral cancer and the need for bone grafting at the time of dental implant placement. PMID:24421999

  15. Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature.

    PubMed

    Hasan, Istabrak; Bourauel, Christoph; Mundt, Torsten; Stark, Helmut; Heinemann, Friedhelm

    2014-02-01

    In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with <3 mm diameter have a risk of fracture in clinical practice. The survival rate of the small-diameter and mini dental implants over 5 years was 98.3-99.4%.

  16. Evaluation of dental implants as a risk factor for the development of bisphosphonate-related osteonecrosis of the jaw in breast cancer patients.

    PubMed

    Matsuo, Akira; Hamada, Hayato; Takahashi, Hidetoshi; Okamoto, Ayako; Kaise, Hiroshi; Chikazu, Daichi

    2016-09-01

    It remains unclear whether dental implants are a risk factor for the development of bisphosphonate-related osteonecrosis of the jaw (BRONJ). We retrospectively evaluated the status of dental implants in patients given intravenous bisphosphonates (BPs) in a breast cancer cohort to elucidate the risk for BRONJ at the implant site. We established a BRONJ oral monitoring program for 247 breast cancer patients given intravenous BP in our institution. The 3-year cumulative incidence rate was determined. The systemic and local risk factors of 44 patients who completed comprehensive oral examinations were evaluated by logistic regression analysis. The 3-year cumulative incidence rate of the 247 patients was 0.074 % (8/247, 95 % CI 0.0081-0.014). In the 44 orally examined patients, 6 (13.6 %: 6/44) had dental implants. Of these 6 patients, 1 developed BRONJ at the implant site. There were no significant differences in the age, total BP treatment period, number of residual teeth, time of regular oral monitoring, oral hygiene level, or dental implant insertion. Although a case of ONJ was identified, dental implants which were inserted before intravenous BP administration were not a risk factor for the development of ONJ in breast cancer patients.

  17. In situ microradioscopy and microtomography of fatigue-loaded dental two-piece implants.

    PubMed

    Wiest, Wolfram; Zabler, Simon; Rack, Alexander; Fella, Christian; Balles, Andreas; Nelson, Katja; Schmelzeisen, Rainer; Hanke, Randolf

    2015-11-01

    Synchrotron real-time radioscopy and in situ microtomography are the only techniques providing direct visible information on a micrometre scale of local deformation in the implant-abutment connection (IAC) during and after cyclic loading. The microgap formation at the IAC has been subject to a number of studies as it has been proposed to be associated with long-term implant success. The next step in this scientific development is to focus on the in situ fatigue procedure of two-component dental implants. Therefore, an apparatus has been developed which is optimized for the in situ fatigue analysis of dental implants. This report demonstrates both the capability of in situ radioscopy and microtomography at the ID19 beamline for the study of cyclic deformation in dental implants. The first results show that it is possible to visualize fatigue loading of dental implants in real-time radioscopy in addition to the in situ fatigue tomography. For the latter, in situ microtomography is applied during the cyclic loading cycles in order to visualize the opening of the IAC microgap. These results concur with previous ex situ studies on similar systems. The setup allows for easily increasing the bending force, to simulate different chewing situations, and is, therefore, a versatile tool for examining the fatigue processes of dental implants and possibly other specimens.

  18. Impact of Dental Implant Surface Modifications on Osseointegration

    PubMed Central

    Smeets, Ralf; Stadlinger, Bernd; Schwarz, Frank; Beck-Broichsitter, Benedicta; Jung, Ole; Precht, Clarissa; Kloss, Frank; Gröbe, Alexander; Heiland, Max

    2016-01-01

    Objective. The aim of this paper is to review different surface modifications of dental implants and their effect on osseointegration. Common marketed as well as experimental surface modifications are discussed. Discussion. The major challenge for contemporary dental implantologists is to provide oral rehabilitation to patients with healthy bone conditions asking for rapid loading protocols or to patients with quantitatively or qualitatively compromised bone. These charging conditions require advances in implant surface design. The elucidation of bone healing physiology has driven investigators to engineer implant surfaces that closely mimic natural bone characteristics. This paper provides a comprehensive overview of surface modifications that beneficially alter the topography, hydrophilicity, and outer coating of dental implants in order to enhance osseointegration in healthy as well as in compromised bone. In the first part, this paper discusses dental implants that have been successfully used for a number of years focusing on sandblasting, acid-etching, and hydrophilic surface textures. Hereafter, new techniques like Discrete Crystalline Deposition, laser ablation, and surface coatings with proteins, drugs, or growth factors are presented. Conclusion. Major advancements have been made in developing novel surfaces of dental implants. These innovations set the stage for rehabilitating patients with high success and predictable survival rates even in challenging conditions. PMID:27478833

  19. Analysis of the causes of dental implant fracture: A retrospective clinical study.

    PubMed

    Stoichkov, Biser; Kirov, Dimitar

    2018-01-01

    Fracture of osseointegrated dental implants is the most severe mechanical complication. The aim of the present study was to analyze possible causative factors for implant body fracture. One hundred and one patients with 218 fitted implants and a follow-up period of 3 to 10 years were studied. Factors associated with biomechanical and physiologic overloading such as parafunctional activity (eg, bruxism), occlusion, and cantilevers, and factors related to the planning of the dental prosthesis, available bone volume, implant area, implant diameter, number of implants, and their inclination were tracked. The impact of their effect was analyzed using the Bonferroni-corrected post-hoc Mann-Whitney test for each group. The incidence of dental implant fracture was 2.3% in the investigated cases. Improper treatment planning, bruxism, and time of the complication setting in were the main factors leading to this complication. Typical size effect was established only for available bruxism, occlusal errors, and their activity duration. These complications were observed most often with single crown prostheses, and in combination with parafunctional activities such as bruxism and lack of implant-protected occlusion. Occlusal overload due to bruxism or inappropriate or inadequate occlusion as a single factor or a combination of these factors during the first years after the functional load can cause implant fracture. Fracture of the implant body more frequently occurred with single crowns than with other implant-supported fixed dental prostheses.

  20. Immediate loading of subcrestally placed dental implants in anterior and premolar sites.

    PubMed

    Henningsen, Anders; Smeets, Ralf; Köppen, Kai; Sehner, Susanne; Kornmann, Frank; Gröbe, Alexander; Heiland, Max; Gerlach, Till

    2017-11-01

    Immediate loading of dental implants has been evolving into an appropriate procedure for the treatment of partially edentulous jaws. The purpose of this study was to evaluate the clinical success and radiological outcome of immediately and delayed loaded dental implants in anterior and premolar sites. In this retrospective study, data of 163 individuals requiring tooth removal with subsequent implant placement in anterior and premolar sites were analyzed. Implants were immediately loaded by provisional acrylic resin bridges or loaded with delay. Implants were followed up annually for up to 9 years including intraoral radiographs. A total of 285 implants in 163 patients were placed. 218 implants were immediately loaded and 67 implants with delay. Fifteen implants failed during the follow-up period resulting in survival rates of 94.5% for immediate loading and 95.5% for delayed loading. After an initial decrease of 0.3 mm in the first 12 months the marginal bone level remained stable. No statistically significant differences were found in marginal bone loss between immediately and delayed loaded implants (P = 0.518, 95% CI). Within the limits of this study, immediate loading of immediately subcrestally placed dental implants in anterior and premolar sites is a reliable treatment option for dental rehabilitation. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Long-term Survival of Straumann Dental Implants with TPS Surfaces: A Retrospective Study with a Follow-up of 12 to 23 Years.

    PubMed

    Becker, Stephan T; Beck-Broichsitter, Benedicta E; Rossmann, Christian M; Behrens, Eleonore; Jochens, Arne; Wiltfang, Jörg

    2016-06-01

    The aim of this study was to evaluate the long-term dental implant survival rates of Straumann dental implants in a university hospital environment over 12 to 23 years. A total of 388 Straumann dental implants with titanium-sprayed surfaces (TPS) were inserted in 92 patients between 1988 and 1999 in the Department of Oral and Maxillofacial Surgery of the University Hospital Schleswig-Holstein in Kiel, and they were reevaluated with standardized clinical and radiological exams. Kaplan-Meier analyses were performed for individual factors. Cox proportional hazard regression analysis was used to detect the factors influencing long-term implant failure. The long-term implant survival rate was 88.03% after an observation time of 12.2 to 23.5 years. Cox regression revealed statistically significant influences of the International Team for Implantology (ITI) implantation type (p = .00354) and tobacco smoking (p = .01264) on implant failure. A proportion 82.8% of the patients with implant losses had a medical history of periodontitis. Peri-implantitis was diagnosed in 9.7% of the remaining implants in the long-term survey. This study emphasized the long-term rehabilitation capabilities of Straumann dental implants in complex cases. The survival rates after several years constitute important information for patients, as well as for clinicians, in deciding about different concepts of tooth replacement. Patient-related and technical factors - determined before implant placement - could help to predict the risk of implant loss. © 2015 Wiley Periodicals, Inc.

  2. The implant infection paradox: why do some succeed when others fail? Opinion and discussion paper.

    PubMed

    Yue, C; Zhao, B; Ren, Y; Kuijer, R; van der Mei, H C; Busscher, H J; Rochford, E T J

    2015-06-05

    Biomaterial-implants are frequently used to restore function and form of human anatomy. However, the presence of implanted biomaterials dramatically elevates infection risk. Paradoxically, dental-implants placed in a bacteria-laden milieu experience moderate failure-rates, due to infection (0.0-1.1%), similar to the ones of joint-arthroplasties placed in a near-sterile environment (0.1-1.3%). Transcutaneous bone-fixation pins breach the immune-barrier of the epidermis, exposing underlying sterile-tissue to an unsterile external environment. In contrast to dental-implants, also placed in a highly unsterile environment, these pins give rise to relatively high infection-associated failure-rates of up to 23.0%. Herein, we attempt to identify causes as to why dental-implants so often succeed, where others fail. The major part of all implants considered are metal-made, with similar surface-finishes. Material choice was therefore discarded as underlying the paradox. Antimicrobial activity of saliva has also been suggested as a cause for the success of dental-implants, but was discarded because saliva is the implant-site-fluid from which viable bacteria adhere. Crevicular fluid was discarded as it is largely analogous to serum. Instead, we attribute the relative success of dental-implants to (1) ability of oral tissues to heal rapidly in the continuous presence of commensal bacteria and opportunistic pathogens, and (2) tolerance of the oral immune-system. Inability of local tissue to adhere, spread and grow in presence of bacteria and an intolerant immune-system are identified as the likely main causes explaining the susceptibility of other implants to infection-associated failure. In conclusion, it is the authors' belief that new anti-infection strategies for a wide range of biomaterial-implants may be derived from the relative success of dental-implants.

  3. Evaluating the Effectiveness of Biomaterial Removal from Dental Implant Drills

    DTIC Science & Technology

    2016-06-13

    effectiveness o f biomateria l removal from dental implant dri l Is Is appropriately acknowledged and beyond brief excerpts. is with the perm issio n...certifies that the use of any copyrighted material in the thesis manuscript entitled: Evaluating the effectiveness of biomaterial removal from dental ...effectiveness of biomaterial removal from dental implant drills STEPHANIE M. PRICE, DDS B.M.E. University of Delaware, Newark, DE 1995 D.D.S. University

  4. The status of undergraduate implant education in dental schools outside the United States.

    PubMed

    Seckinger, R J; Weintraub, A M; Berthold, P; Weintraub, G S

    1995-01-01

    Over the past 20 years the incorporation of implant dentistry into academia has been documented in some detail for North American dental schools but has not been pursued on an international level. In June of 1993, we surveyed 51 dental schools outside of the United States affiliated with the University of Pennsylvania School of Dental Medicine's Office of International Relations concerning their teaching involvement with implant dentistry. Results from the 44 (86 percent) responding schools suggest that implant dentistry is being incorporated into predoctoral curriculums. Industrialized countries were more inclined to provide implant education. Insufficient time and the thought that the predoctoral level was not the place for implant dentistry were cited as some of the reasons for not incorporating implant dentistry into the curriculum. Oral surgery, prosthodontics, and periodontics departments developed and administered the implant curriculum. Formats varied among schools with respect to allotted time, curricular placement, laboratory experience, and clinical participation. Didactic material most frequently presented included a historical overview, diagnosis and treatment planning, classification of dental implants, and surgical and prosthetic concepts. Clinical involvement varied from actual implant placement to observation of prosthodontic procedures. Results were categorized based on the TOEFL (Test of English as a Foreign Language) classification of countries in six regions.

  5. Timing of soft tissue management around dental implants: a suggested protocol.

    PubMed

    Kadkhodazadeh, Mahdi; Amid, Reza; Kermani, Mehdi Ekhlasmand; Mirakhori, Mahdieh; Hosseinpour, Sepanta

    2017-01-01

    Survival of dental implants depends on several factors; soft tissue (ST) management around dental implants is one of the foremost. Several studies have suggested techniques for ST management around dental implants, but none of them has discussed a suitable timetable for this process. This study aimed to review published articles related to the timing of ST management around dental implants and suggest a customized treatment protocol. A search of the PubMed database was conducted; the search was limited to English-language articles published from January 1995 to July 2015 with available full texts. Only in vivo studies and clinical trials in relation to the terms soft tissue management, management timing, keratinized mucosa, free gingival graft, connective tissue graft, soft tissue, augmentation, and dental implant were included. A total of 492 articles were reviewed, and eventually 42 articles were thoroughly evaluated. Those with treatment protocols in terms of the timing of ST grafting were selected and classified. ST management around dental implants may be done prior to the surgical phase, after the surgical phase, before loading, or even after loading. A thick gingival biotype is more suitable for implant placement, providing more favorable esthetic results. A treatment plan should be based on individual patient needs as well as the knowledge and experience of the clinician. The width and thickness of keratinized tissues, the need for bone management, and local risk factors that influence esthetic results determine the appropriate time for ST augmentation procedures.

  6. Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

    PubMed Central

    Sukotjo, Cortino

    2013-01-01

    Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices. PMID:23678387

  7. Use of Metallic Endosseous Implants as a Tooth Substitute

    DTIC Science & Technology

    1975-11-25

    is exposed in the oral cavity and placed in function with the opposing dentition. BACKGROUND An appraisal of published work in the field of dental ...implant reveals that the dental literature abounds with articles concerned with the use of implants. The reports are mainly of clinical procedures and...metallic blades driven into the bone to become an anchor for prosthetic appliances. A complete critical review of the literature on dental implants was

  8. Success and Survival Rates of Dental Implants Restored at an Undergraduate Dental Clinic: A 13-Year Retrospective Study with a Mean Follow-up of 5.8 Years.

    PubMed

    Daneshvar, Shahrzad S; Matthews, Debora C; Michuad, Pierre-Luc; Ghiabi, Edmond

    2016-01-01

    The purpose of this study was to evaluate the clinical, radiographic, and patient-based outcomes of dental implants placed at an undergraduate student dental clinic. A retrospective study was performed to determine the success and survival rates of dental implants placed at the undergraduate dental clinic at Dalhousie University between January 1999 and January 2012. Only patients with a minimum of 1-year follow-up were included. Clinical and radiographic assessments determined implant success and survival rates. Questionnaires recorded patients' satisfaction with esthetics, comfort, and ease of hygiene. Of the 352 patients (n = 591 implants) who received implants over 13 years, 165 patients completed the clinical and radiographic examinations. By the end of the study period, demographic information and implant characteristics were collected for 111 (n = 217 implants; 47.5% in the maxilla, 52.6% in the mandible) of these patients. Of those assessed clinically, 36.4% were males and 63.6% females, with a mean age of 56.1 ± 14.15 years (range, 17 to 86 years) at the time of implant placement. The mean follow-up period was 5.8 years (range, 1 to 13 years). The overall implant success and survival rates were 88.0% and 97.2%, respectively. No observable bone loss was evident in 88.0% of the surviving implants. There were no implant fractures. Most patients (91.2%) were very satisfied with the implant restoration appearance, 88.0% were very comfortable with the implant, 92.6% were very satisfied with their ability to chew, and 84.8% reported easy hygiene maintenance at the implant sites. Implant success and survival in an undergraduate student clinic were comparable to those reported in the literature. It seems that inexperienced students were able to provide restorations that were very satisfying to the patients.

  9. Survival of dental implants in patients with Down syndrome: A case series.

    PubMed

    Limeres Posse, Jacobo; López Jiménez, Julian; Ruiz Villandiego, José C; Cutando Soriano, Antonio; Fernández Feijoo, Javier; Linazasoro Elorza, Maialen; Diniz Freitas, Márcio; Diz Dios, Pedro

    2016-12-01

    The need for tooth replacement in individuals with Down syndrome (DS) is explained by the high prevalence of dental agenesis and by the premature loss of teeth through severe periodontal disease. Dental implants may be the dental procedure of choice in some of these patients. The purpose of this clinical study was to analyze dental implant survival in a series of patients with DS. This was a multicenter, retrospective, observational study. Information on patients was gathered using a standardized questionnaire designed specifically for this study, including personal details, oral health status, information on the surgical and prosthetic phases, and follow-up visits. The questionnaire was sent to centers registered with the research network of the Spanish Society of Special Needs Dentistry (SEOENE). Patients with DS aged 18 years or older were included in the study if they had at least 1 dental implant and the corresponding prosthesis and had been followed up for at least a year. The study population was formed of 25 adult patients (13 men and 12 women) aged between 19 and 60 years. The interventions were performed by 5 different dental surgeons, usually under general anesthesia or deep sedation (n=17 patients). A total of 73 implants were inserted, 30 in the maxilla and 43 in the mandible, most commonly in the anterior region (n=51). The mean time to loading the implants was 4.1 ±1.3 months after surgery (range, 1 to 7 months). All patients completed prosthetic rehabilitation; the most frequent design used was the single fixed prosthesis (n=13 patients). A total of 17 (23.2%) implants failed in 8 (32%) patients; the majority (n=14 implants) failed in the postsurgical period before implant loading. The distribution by patients was 1 implant failure in 6 patients, 3 failures in 1 patient, and 8 failures in 1 patient. Dental implant survival is lower in individuals with DS than in the general population. The reasons for early implant failure in these patients have still not been clearly identified. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. DEALING WITH DENTAL IMPLANT FAILURES

    PubMed Central

    Levin, Liran

    2008-01-01

    An implant-supported restoration offers a predictable treatment for tooth replacement. Reported success rates for dental implants are high. Nevertheless, failures that mandate immediate implant removal do occur. The consequences of implant removal jeopardize the clinician's efforts to accomplish satisfactory function and esthetics. For the patient, this usually involves further cost and additional procedures. The aim of this paper is to describe different methods and treatment modalities to deal with dental implant failure. The main topics for discussion include identifying the failing implant, implants replacing failed implants at the exact site, and the use of other restorative options. When an implant fails, a tailor made treatment plan should be provided to each patient according to all relevant variables. Patients should be informed regarding all possible treatment modalities following implant failure and give their consent to the most appropriate treatment option for them. PMID:19089213

  11. Genotoxicity of corrosion eluates obtained from endosseous implants.

    PubMed

    Ribeiro, Daniel Araki; Matsumoto, Mariza Akemi; Padovan, Luís Eduardo Marques; Marques, Mariângela Esther Alencar; Salvadori, Daisy Maria Fávero

    2007-03-01

    Commercially pure titanium alloys are currently used as metallic biomaterials in implantology. Corrosion phenomena appear to play a decisive role in metallic implant long-term behavior. Thus, the goal of this study was to examine the genotoxic potential of corrosion eluates obtained from dental implants using Chinese ovary hamster cells in vitro by the single-cell gel (comet) assay. This technique detects deoxyribonucleic acid strand breaks in individual cells in alkaline conditions. The materials tested included 3 dental implants commercially available. Each of the tested materials was corroded in a solution consisting of equal amounts of acetic acid and sodium chloride (0.1 M) for 1, 3, 7, 14, and 21 days. The Chinese ovary hamster cultures were then exposed to all corrosion eluates obtained from endosseous dental implants for 30 minutes at 37 degrees C. None of the eluates was found to exhibit genotoxicity, regardless of the type of dental implant used. The results suggest that all dental implants tested in this study did not induce deoxyribonucleic acid breakage as depicted by the single-cell gel (comet) assay.

  12. Basic concepts and techniques of dental implants.

    PubMed

    Tagliareni, Jonathan M; Clarkson, Earl

    2015-04-01

    Dental implants provide completely edentulous and partial edentulous patients the function and esthetics they had with natural dentition. It is critical to understand and apply predictable surgical principles when treatment planning and surgically restoring edentulous spaces with implants. This article defines basic implant concepts that should be meticulously followed for predictable results when treating patients and restoring dental implants. Topics include biological and functional considerations, biomechanical considerations, preoperative assessments, medical history and risk assessments, oral examinations, radiographic examinations, contraindications, and general treatment planning options. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Surface Modification of Dental Titanium Implant by Layer-by-Layer Electrostatic Self-Assembly

    PubMed Central

    Shi, Quan; Qian, Zhiyong; Liu, Donghua; Liu, Hongchen

    2017-01-01

    In vivo implants that are composed of titanium and titanium alloys as raw materials are widely used in the fields of biology and medicine. In the field of dental medicine, titanium is considered to be an ideal dental implant material. Good osseointegration and soft tissue closure are the foundation for the success of dental implants. Therefore, the enhancement of the osseointegration and antibacterial abilities of titanium and its alloys has been the focus of much research. With its many advantages, layer-by-layer (LbL) assembly is a self-assembly technique that is used to develop multilayer films based on complementary interactions between differently charged polyelectrolytes. The LbL approach provides new methods and applications for the surface modification of dental titanium implant. In this review, the application of the LbL technique to surface modification of titanium including promoting osteogenesis and osseointegration, promoting the formation and healing of soft tissues, improving the antibacterial properties of titanium implant, achieving local drug delivery and sustained release is summarized. PMID:28824462

  14. Zirconia in dental implantology: A review

    PubMed Central

    Apratim, Abhishek; Eachempati, Prashanti; Krishnappa Salian, Kiran Kumar; Singh, Vijendra; Chhabra, Saurabh; Shah, Sanket

    2015-01-01

    Background: Titanium has been the most popular material of choice for dental implantology over the past few decades. Its properties have been found to be most suitable for the success of implant treatment. But recently, zirconia is slowly emerging as one of the materials which might replace the gold standard of dental implant, i.e., titanium. Materials and Methods: Literature was searched to retrieve information about zirconia dental implant and studies were critically analyzed. PubMed database was searched for information about zirconia dental implant regarding mechanical properties, osseointegration, surface roughness, biocompatibility, and soft tissue health around it. The literature search was limited to English language articles published from 1975 to 2015. Results: A total of 45 papers met the inclusion criteria for this review, among the relevant search in the database. Conclusion: Literature search showed that some of the properties of zirconia seem to be suitable for making it an ideal dental implant, such as biocompatibility, osseointegration, favourable soft tissue response and aesthetics due to light transmission and its color. At the same time, some studies also point out its drawbacks. It was also found that most of the studies on zirconia dental implants are short-term studies and there is a need for more long-term clinical trials to prove that zirconia is worth enough to replace titanium as a biomaterial in dental implantology. PMID:26236672

  15. Clinical Outcome of Hydroxyapatite Coated, Bioactive Glass Coated, and Machined Ti6Al4V Threaded Dental Implant in Human Jaws: A Short-Term Comparative Study.

    PubMed

    Mistry, Surajit; Roy, Rajiv; Kundu, Biswanath; Datta, Someswar; Kumar, Manoj; Chanda, Abhijit; Kundu, Debabrata

    2016-04-01

    Growing aspect of endosseous implant research is focused on surface modification of dental implants for the purpose of improving osseointegration. The aim of this study was to evaluate and compare the clinical outcome (ie, osseointegration) of hydroxyapatite coated, bioactive glass coated and machined titanium alloy threaded dental implants in human jaw bone after implantation. One hundred twenty-six implants (45 hydroxyapatite coated, 41 bioactive glass coated, and 40 machined titanium implants) have been placed in incisor areas of 62 adult patients. Outcome was assessed up to 12 months after prosthetic rehabilitation using different clinical and radiological parameters. Surface roughness of failed implants was analyzed by laser profilometer. Hydroxyapatite and bioactive glass coating materials were nontoxic and biocompatible. Least marginal bone loss in radiograph, significantly higher (P < 0.05) interface radiodensity, and less interfacial gaps were observed in computed tomography with bioactive glass coated implants at anterior maxilla compared to other 2 types. Bioactive glass coated implants are equally safe and effective as hydroxyapatite coated and machined titanium implants in achieving osseointegration; therefore, can be effectively used as an alternative coating material for dental implants.

  16. Retrospective cohort study of the clinical performance of 1-stage dental implants.

    PubMed

    Carr, Alan B; Choi, Yong-Geun; Eckert, Steven E; Desjardins, Ronald P

    2003-01-01

    To evaluate long-term clinical performance of 1-stage dental implant prostheses at a single clinic, emphasizing clinical and demographic characteristics that affect implant survival. Dental records of all 308 patients (674 implants) treated with 1-stage implants at Mayo Clinic from October 1993 through May 2000 were reviewed from implant placement to last visit. Exposure and outcome variables affecting performance were collected separately to control bias in the data collection process. Additional confounding factors (age and sex) were adjusted with the stratified Cox proportional hazards model. Implant survival was determined by means of a Kaplan-Meier survival estimate. The log-rank test was used to determine the role of clinical and demographic variables in implant survival. The relative risk associated with the possible effect of clinical and demographic variables on implant survival was estimated with the Cox proportional hazards model. The implant survival rate (n = 654 implants) was 97% (mean +/- SD follow-up, 21.0 +/- 18.8 months; range, 1 to 78 months). Performance bias was limited because nearly all patients were treated by 1 prosthodontist. Two implants failed after loading (6 and 9 months). The incidence of complications was less than 4%. Among the implant failures, use of heterogeneous bone graft was associated with 4.8 times more failures than was use of autogenous bone graft (P = .04). After augmentation, delaying implant placement for 5 to 6 months resulted in 8.6 times more failures than the rate after earlier placement (P < .001). Retrospective review of the clinical performance of a 1-stage dental implant system yielded a 97% survival rate, with no failures noted after 13 months. Prosthetic complications were low, especially for fixed implant prostheses. Clinical performance of 1-stage dental implant prostheses between 1993 and 2000 demonstrated a high level of predictability.

  17. Influence of the height of the external hexagon and surface treatment on fatigue life of commercially pure titanium dental implants.

    PubMed

    Gil, Francisco Javier; Aparicio, Conrado; Manero, Jose M; Padros, Alejandro

    2009-01-01

    This study evaluated the effect of external hexagon height and commonly applied surface treatments on the fatigue life of titanium dental implants. Electropolished commercially pure titanium dental implants (seven implants per group) with three different external hexagon heights (0.6, 1.2, and 1.8 mm) and implants with the highest external hexagon height (1.8 mm) and different surface treatments (electropolishing, grit blasting with aluminium oxide, and acid etching with sulfuric acid) were tested to evaluate their mechanical fatigue life. To do so, 10-Hz triangular flexural load cycles were applied at 37 degrees C in artificial saliva, and the number of load cycles until implant fracture was determined. Tolerances of the hexagon/abutment fit and implant surface roughness were analyzed by scanning electron microscopy and light interferometry. Transmission electron microscopy and electron diffraction analyses of titanium hydrides were performed. First, the fatigue life of implants with the highest hexagon (8,683 +/- 978 load cycles) was more than double that of the implants with the shortest hexagons (3,654 +/- 789 load cycles) (P < .02). Second, the grit-blasted implants had the longest fatigue life of the tested materials (21,393 +/- 2,356 load cycles), which was significantly greater than that of the other surfaces (P < .001). The compressive surface residual stresses induced when blasting titanium are responsible for this superior mechanical response. Third, precipitation of titanium hydrides in grain boundaries of titanium caused by hydrogen adsorption from the acid solution deteriorates the fatigue life of acid-etched titanium dental implants. These implants had the shortest fatigue life (P < .05). The fatigue life of threaded root-form dental implants varies with the height of the external hexagon and/or the surface treatment of the implant. An external hexagon height of 1.8 mm and/or a blasting treatment appear to significantly increase fatigue life of dental implants.

  18. Piezosurgery in Bone Augmentation Procedures Previous to Dental Implant Surgery: A Review of the Literature

    PubMed Central

    Magrin, Gabriel Leonardo; Sigua-Rodriguez, Eder Alberto; Goulart, Douglas Rangel; Asprino, Luciana

    2015-01-01

    The piezosurgery has been used with increasing frequency and applicability by health professionals, especially those who deal with dental implants. The concept of piezoelectricity has emerged in the nineteenth century, but it was applied in oral surgery from 1988 by Tomaso Vercellotti. It consists of an ultrasonic device able to cut mineralized bone tissue, without injuring the adjacent soft tissue. It also has several advantages when compared to conventional techniques with drills and saws, such as the production of a precise, clean and low bleed bone cut that shows positive biological results. In dental implants surgery, it has been used for maxillary sinus lifting, removal of bone blocks, distraction osteogenesis, lateralization of the inferior alveolar nerve, split crest of alveolar ridge and even for dental implants placement. The purpose of this paper is to discuss the use of piezosurgery in bone augmentation procedures used previously to dental implants placement. PMID:26966469

  19. Comparison of bioactive glass coated and hydroxyapatite coated titanium dental implants in the human jaw bone.

    PubMed

    Mistry, S; Kundu, D; Datta, S; Basu, D

    2011-03-01

    Current trends in clinical dental implant therapy include modification of titanium surfaces for the purpose of improving osseointegration by different additive (bioactive coatings) and subtractive processes (acid etching, grit-blasting). The aim of this study was to evaluate and compare the behaviour of hydroxyapatite and the newly developed bioactive glass coated implants (62 implants) in osseous tissue following implantation in 31 patients. Bioactive glass and hydroxyapatite was suitably coated on titanium alloy. Hydroxyapatite coating was applied on the implant surface by air microplasma spray technique and bioactive glass coating was applied by vitreous enamelling technique. The outcome was assessed up to 12 months after prosthetic loading using different clinical and radiological parameters. Hydroxyapatite and bioactive glass coating materials were non-toxic and biocompatible. Overall results showed that bioactive glass coated implants were as equally successful as hydroxyapatite in achieving osseointegration and supporting final restorations. The newly developed bioactive glass is a good alternative coating material for dental implants. © 2011 Australian Dental Association.

  20. Conservative surgical and microsurgical techniques for the management of dental implants that impinge on the inferior alveolar nerve.

    PubMed

    Gennaro, Paolo; Chisci, Glauco; Gabriele, Guido; Iannetti, Giorgio

    2014-07-01

    Loss of sensation in the lip after insertion of an implant is annoying. The aim of this paper was to describe two techniques for management of osseointegrated dental implants that impinge on the mandibular nerve, the purpose of which is to improve sensation without unscrewing the dental implant. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. The Effect of Titanium Surface Roughness on Growth, Differentiation, and Protein Synthesis of Cartilage and Bone Cells

    DTIC Science & Technology

    1996-05-01

    at San Antonio Supervising Professors: Barbara D. Boyan, Ph.D. David L. Cochran, D.D.S., Ph.D. Placement of endosseous dental implants requires the...titanium substratum was chosen for these studies since most medical and dental implants are fabricated from titanium The titanium was cut into uniform...electron microscopy to evaluate the histomorphometry of the implant-bone interface of various titanium and ceramic dental implants placed in dog mandibles

  2. Comparison of conventional and synchrotron-radiation-based microtomography of bone around dental implants

    NASA Astrophysics Data System (ADS)

    Cattaneo, Paolo M.; Dalstra, Michel; Beckmann, Felix; Donath, Tilman; Melsen, Birte

    2004-10-01

    This study explores the application of conventional micro tomography (μCT) and synchrotron radiation (SR) based μCT to evaluate the bone around titanium dental implants. The SR experiment was performed at beamline W2 of HASYLAB at DESY using a monochromatic X-ray beam of 50 keV. The testing material consisted of undecalcified bone segments harvested from the upper jaw of a macaca fascicularis monkey each containing a titanium dental implant. The results from the two different techniques were qualitatively compared with conventional histological sections examined under light microscopy. The SR-based μCT produced images that, especially at the bone-implant interface, are less noisy and sharper than the ones obtained with conventional μCT. For the proper evaluation of the implant-bone interface, only the SR-based μCT technique is able to display the areas of bony contact and visualize the true 3D structure of bone around dental implants correctly. This investigation shows that both conventional and SR-based μCT scanning techniques are non-destructive methods, which provide detailed images of bone. However with SR-based μCT it is possible to obtain an improved image quality of the bone surrounding dental implants, which display a level of detail comparable to histological sections. Therefore, SR-based μCT scanning could represent a valid, unbiased three-dimensional alternative to evaluate osseointegration of dental implants

  3. Decoronation followed by dental implants placement: fundamentals, applications and explanations

    PubMed Central

    Consolaro, Alberto; Ribeiro, Paulo Domingos; Cardoso, Maurício A.; Miranda, Dario A. Oliveira; Salfatis, Monica

    2018-01-01

    ABSTRACT Dental arches areas with teeth presenting dentoalveolar ankylosis and replacement root resorption can be considered as presenting normal bone, in full physiological remodeling process; and osseointegrated implants can be successfully placed. Bone remodeling will promote osseointegration, regardless of presenting ankylosis and/or replacement root resorption. After 1 to 10 years, all dental tissues will have been replaced by bone. The site, angulation and ideal positioning in the space to place the implant should be dictated exclusively by the clinical convenience, associated with previous planning. One of the advantages of decoronation followed by dental implants placement in ankylosed teeth with replacement resorption is the maintenance of bone volume in the region, both vertical and horizontal. If possible, the buccal part of the root, even if thin, should be preserved in the preparation of the cavity for the implant, as this will maintain gingival tissues looking fully normal for long periods. In the selection of cases for decoronation, the absence of microbial contamination in the region - represented by chronic periapical lesions, presence of fistula, old unconsolidated root fractures and active advanced periodontal disease - is important. Such situations are contraindications to decoronation. However, the occurrence of dentoalveolar ankylosis and replacement resorption without contamination should neither change the planning for implant installation, nor the criteria for choosing the type and brand of dental implant to be used. Failure to decoronate and use dental implants has never been reported. PMID:29791693

  4. Integrating three-dimensional digital technologies for comprehensive implant dentistry.

    PubMed

    Patel, Neal

    2010-06-01

    The increase in the popularity of and the demand for the use of dental implants to replace teeth has encouraged advancement in clinical technology and materials to improve patients' acceptance and clinical outcomes. Recent advances such as three-dimensional dental radiography with cone-beam computed tomography (CBCT), precision dental implant planning software and clinical execution with guided surgery all play a role in the success of implant dentistry. The author illustrates the technique of comprehensive implant dentistry planning through integration of computer-aided design/computer-aided manufacturing (CAD/CAM) and CBCT data. The technique includes clinical treatment with guided surgery, including the creation of a final restoration with a high-strength ceramic (IPS e.max CAD, Ivoclar Vivadent, Amherst, N.Y.). The author also introduces a technique involving CAD/CAM for fabricating custom implant abutments. The release of software integrating CEREC Acquisition Center with Bluecam (Sirona Dental Systems, Charlotte, N.C.) chairside CAD/CAM and Galileos CBCT imaging (Sirona Dental Systems) allows dentists to plan implant placement, perform implant dentistry with increased precision and provide predictable restorative results by using chairside IPS e.max CAD. The precision of clinical treatment provided by the integration of CAD/CAM and CBCT allows dentists to plan for ideal surgical placement and the appropriate thickness of restorative modalities before placing implants.

  5. Readability of websites containing information on dental implants.

    PubMed

    Jayaratne, Yasas S N; Anderson, Nina K; Zwahlen, Roger A

    2014-12-01

    It is recommended that health-related materials for patients be written at sixth grade level or below. Many websites oriented toward patient education about dental implants are available, but the readability of these sites has not been evaluated. To assess readability of patient-oriented online information on dental implants. Websites containing patient-oriented information on dental implants were retrieved using the Google search engine. Individual and mean readability/grade levels were calculated using standardized formulas. Readability of each website was classified as easy (≤ 6th-grade level) or difficult (≥ 10th grade level). Thirty nine websites with patient-oriented information on dental implant were found. The average readability grade level of these websites was 11.65 ± 1.36. No website scored at/below the recommended 6th grade level. Thirty four of 39 websites (87.18%) were difficult to read. The number of characters, words, and sentences on these sites varied widely. All patient-oriented websites on dental implants scored above the recommended grade level, and majority of these sites were "difficult" in their readability. There is a dire need to create patient information websites on implants, which the majority can read. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. The influence of dental implants in periapical and panoramic radiographs and cone beam computed tomography images: a clinical study.

    PubMed

    Felix, Rafael Perdomo; Shinkai, Rosemary Sadami Arai; Rockenbach, Maria Ivete Bolzan

    2018-01-01

    The aim of this study was to analyze the influence of dental implants on the radiographic density of the peri-implant region in tomographic and radiographic examinations. A sample of 21 dental implants from 10 patients with Brånemark-protocol prostheses was evaluated based on postoperative control images, including periapical radiography (paralleling technique), panoramic radiography, and cone beam computed tomography (CBCT). The density means of 6 defined areas near dental implants were calculated and compared considering their locations and the different imaging examinations. The CBCT examinations showed significantly different densities among the measured areas (P < 0.001), while there were no significant differences among the density means of the various areas in periapical radiographs (P = 0.430) and panoramic radiographs (P = 0.149). The highest mean densities were observed in areas closer to the implants in all the examinations: CBCT (127.88 and 120.71), panoramic (106.51 and 106.09), and periapical (120.32). The sagittal CBCT images were measured in 2 different sections, and in both sections those areas closer to implants showed mean densities that were significantly higher than means from more distant areas (P < 0.001). Means from distant areas on CBCT slice imaging were significantly lower than the densities of the same areas on periapical and panoramic examinations. The changes in mean radiographic density values in the peri-implant region confirmed the interference of dental implants in radiographic and tomographic images. CBCT images suffered the greatest interference from dental implants.

  7. Evaluation of possible prognostic factors for the success, survival, and failure of dental implants.

    PubMed

    Geckili, Onur; Bilhan, Hakan; Geckili, Esma; Cilingir, Altug; Mumcu, Emre; Bural, Canan

    2014-02-01

    To analyze the prognostic factors that are associated with the success, survival, and failure rates of dental implants. Data including implant sizes, insertion time, implant location, and prosthetic treatment of 1656 implants have been collected, and the association of these factors with success, survival, and failure of implants was analyzed. The success rate was lower for short and maxillary implants. The failure rate of maxillary implants exceeded that of mandibular implants, and the failure rate of implants that were placed in the maxillary anterior region was significantly higher than other regions. The failure rates of implants that were placed 5 years ago or more were higher than those that were placed later. Anterior maxilla is more critical for implant loss than other sites. Implants in the anterior mandible show better success compared with other locations, and longer implants show better success rates. The learning curve of the clinician influences survival and success rates of dental implants.

  8. [Use of porous titanium nickelide dental implants].

    PubMed

    Radkevich, A A; Galonskiĭ, V G; Gantimurov, A A

    2013-01-01

    The paper presents the results of 20 years clinical experience in dental prosthetics with the use of porous titanium nickelide dental implants. Implants were placed in 565 patients aged 15-17 years. Long-term results analysis showed restorations to function properly after mean follow-up period of 8 years in 435 patients (78.2%) proving this material to be clinically successful.

  9. [Gingival fluid cytokine profile in patients after dental implantation and by periimplantitis].

    PubMed

    Tsarev, V N; Nikolaeva, E N; Ippolitov, E V; Tsareva, T V

    2013-01-01

    The study included 32 patients with complications which have developed 3 months to 14 years after dental implants placement. ELISA method was used to assess cytokines content in various sites of tooth alignment in patients with Herpesviridae and periodontopathogenics bacteria associated periimplantitis. The results prove the necessity for Herpesviridae and selected bacteria monitoring after dental implantation.

  10. Bacteremia following dental implant surgery: preliminary results.

    PubMed

    Bölükbaşı, Nilüfer; Özdemir, Tayfun; Öksüz, Lütfiye; Gürler, Nezahat

    2012-01-01

    The aims of this study were to investigate the incidence of bacteremia, bacteriology and antibiotic susceptibility against to causative bacteria associated with dental implant installation. 30 generally healthy patients were enrolled in this study. Blood samples were collected at baseline and at 30 minutes after dental implant installation and 24 hours after dental implant surgery. Blood samples were cultured in a BACTEC system. The isolated bacteria were identified using conventional methods. Antimicrobial sensitivity tests were performed by disc diffusion. No bacteria were isolated at the baseline and 24 hours after surgery, whereas the prevalence of bacteremia at 30 minutes after dental implant installation was 23%. The isolated bacteria species were Staphylococcus epidermidis, Eubacterium spp., Corynebacterium spp. and Streptococcus viridans. The Staphylococcus epidermidis, which was isolated in three patients, was found to be resistant to penicillin which is first choice of many clinicians. Our findings suggest that installation of dental implants can produce bacteremia. Within the limitations of this study, it can be speculated that the resistance of antibiotics may compromise the routine prophylaxis against infective endocarditis. Therefore use of blood cultures and antibiograms may be suggested in risky patients. The outcome of the present study should be verified using a larger patient group with varying conditions.

  11. Micro finite element analysis of dental implants under different loading conditions.

    PubMed

    Marcián, Petr; Wolff, Jan; Horáčková, Ladislava; Kaiser, Jozef; Zikmund, Tomáš; Borák, Libor

    2018-05-01

    Osseointegration is paramount for the longevity of dental implants and is significantly influenced by biomechanical stimuli. The aim of the present study was to assess the micro-strain and displacement induced by loaded dental implants at different stages of osseointegration using finite element analysis (FEA). Computational models of two mandible segments with different trabecular densities were constructed using microCT data. Three different implant loading directions and two osseointegration stages were considered in the stress-strain analysis of the bone-implant assembly. The bony segments were analyzed using two approaches. The first approach was based on Mechanostat strain intervals and the second approach was based on tensile/compression yield strains. The results of this study revealed that bone surrounding dental implants is critically strained in cases when only a partial osseointegration is present and when an implant is loaded by buccolingual forces. In such cases, implants also encounter high stresses. Displacements of partially-osseointegrated implant are significantly larger than those of fully-osseointegrated implants. It can be concluded that the partial osseointegration is a potential risk in terms of implant longevity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Scientific Fundamentals and Technological Development of Novel Biocompatible/Corrosion Resistant Ultrananocrystalline Diamond (UNCD) Coating Enabling Next Generation Superior Metal-Based Dental Implants

    NASA Astrophysics Data System (ADS)

    Kang, Karam

    Current Ti-based dental implants exhibit failure (2-10%), due to various mechanisms, including chemical corrosion of the surface of the TiO2 naturally covered Ti-based implants. This thesis focused on developing a unique biocompatible/bio-inert/corrosion resistant/low cost Ultrananocrystalline Diamond (UNCD) coating (with 3-5 nm grain size) for encapsulation of Tibased micro-implants to potentially eliminate the corrosion/mechanical induced failure of current commercial Ti-based dental implants. Microwave Plasma Chemical Vapor Deposition (MPCVD) and Hot Filament Chemical Vapor Deposition (HFCVD) processes were used to grow UNCD coatings. The surface topography and chemistry of UNCD coatings were characterized using scanning electron microscopy (SEM), Raman, and X-ray photoelectron spectroscopies (XPS) respectively. In conclusion, this thesis contributed to establish the optimal conditions to grow UNCD coatings on the complex 3-D geometry of Ti-based micro-implants, with geometry similar to real implants, relevant to developing UNCD-coated Ti-based dental implants with superior mechanical/chemical performance than current Ti-based implants.

  13. Implant angulation: 2-year retrospective analysis on the influence of dental implant angle insertion on marginal bone resorption in maxillary and mandibular osseous onlay grafts.

    PubMed

    Ramaglia, Luca; Toti, Paolo; Sbordone, Carolina; Guidetti, Franco; Martuscelli, Ranieri; Sbordone, Ludovico

    2015-05-01

    The purpose of this study was to determine the existence of correlations between marginal peri-implant linear bone loss and the angulation of implants in maxillary and mandibular augmented areas over the course of a 2-year survey. Dependent variables described the sample of the present retrospective chart review. By using three-dimensional radiographs, input variables, describing the implant angulation (buccal-lingual angle [φ] and mesial-distal angle [θ]) were measured; outcome variables described survival rate and marginal bone resorption (MBR) around dental implants in autogenous grafts (10 maxillae and 14 mandibles). Pairwise comparisons and linear correlation coefficient were computed. The peri-implant MBR in maxillary buccal and palatal areas appeared less intensive in the presence of an increased angulation of an implant towards the palatal side. Minor MBR was recorded around mandibular dental implants positioned at a right angle and slightly angulated towards the mesial. Resorption in buccal areas may be less intensive as the angulation of placed implants increases towards the palatal area in the maxilla, whereas for the mandible, a greater inclination towards the lingual area could be negative. In the mandibular group, when the implant was slightly angulated in the direction of the distal area, bone resorption seemed to be more marked in the buccal area. In the planning of dental implant placement in reconstructed alveolar bone with autograft, the extremely unfavourable resorption at the buccal aspect should be considered; this marginal bone loss seemed to be very sensitive to the angulation of the dental implant.

  14. Immediate versus delayed loading of strategic mini dental implants for the stabilization of partial removable dental prostheses: a patient cluster randomized, parallel-group 3-year trial.

    PubMed

    Mundt, Torsten; Al Jaghsi, Ahmad; Schwahn, Bernd; Hilgert, Janina; Lucas, Christian; Biffar, Reiner; Schwahn, Christian; Heinemann, Friedhelm

    2016-07-30

    Acceptable short-term survival rates (>90 %) of mini-implants (diameter < 3.0 mm) are only documented for mandibular overdentures. Sound data for mini-implants as strategic abutments for a better retention of partial removable dental prosthesis (PRDP) are not available. The purpose of this study is to test the hypothesis that immediately loaded mini-implants show more bone loss and less success than strategic mini-implants with delayed loading. In this four-center (one university hospital, three dental practices in Germany), parallel-group, controlled clinical trial, which is cluster randomized on patient level, a total of 80 partially edentulous patients with unfavourable number and distribution of remaining abutment teeth in at least one jaw will receive supplementary min-implants to stabilize their PRDP. The mini-implant are either immediately loaded after implant placement (test group) or delayed after four months (control group). Follow-up of the patients will be performed for 36 months. The primary outcome is the radiographic bone level changes at implants. The secondary outcome is the implant success as a composite variable. Tertiary outcomes include clinical, subjective (quality of life, satisfaction, chewing ability) and dental or technical complications. Strategic implants under an existing PRDP are only documented for standard-diameter implants. Mini-implants could be a minimal invasive and low cost solution for this treatment modality. The trial is registered at Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS-ID: DRKS00007589 ( www.germanctr.de ) on January 13(th), 2015.

  15. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series.

    PubMed

    Gay-Escoda, C; Pérez-Álvarez, D; Camps-Font, O; Figueiredo, R

    2016-05-01

    The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Nine participants (57 implants) were included. The patients' median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented.

  16. Survival of dental implants in native and grafted bone in irradiated head and neck cancer patients: a retrospective analysis.

    PubMed

    Buddula, Aravind; Assad, Daniel A; Salinas, Thomas J; Garces, Yolanda I

    2011-01-01

    To study the long-term survival of dental implants placed in native or grafted bone in irradiated bone in subjects who had received radiation for head and neck cancer. A retrospective chart review was conducted for all patients who received dental implants following radiation treatment for head and neck cancer between May 1, 1987 and July 1, 2008. Only patients irradiated with a radiation dose of 50 Gy or greater and those who received dental implants in the irradiated field after head and neck radiation were included in the study. The associations between implant survival and patient/implant characteristics were estimated by fitting univariate marginal Cox proportional hazards models. A total of 48 patients who had prior head and neck radiation had 271 dental implants placed during May 1987-July 2008. There was no statistically significant difference between implant failure in native and grafted bone (P=0.76). Survival of implants in grafted bone was 82.3% and 98.1% in maxilla and mandible, respectively, after 3 years. Survival of implants in native bone in maxilla and mandible was 79.8% and 100%, respectively, after 3 years. For implants placed in the native bone, there was a higher likelihood of failure in the maxilla compared to the mandible and there was also a tendency for implants placed in the posterior region to fail compared to those placed in the anterior region. There was no significant difference in survival when implants were placed in native or grafted bone in irradiated head and neck cancer patients. For implants placed in native bone, survival was significantly influenced by the location of the implant (maxilla or mandible, anterior or posterior).

  17. Can Periimplantitis Be Treated?

    PubMed

    Fu, Jia-Hui; Wang, Hom-Lay

    2015-10-01

    Over the past few decades, dental implants have been found to have high predictability and survival rates because of improvements in knowledge, clinical expertise, and implant designs. As such, dental implants are frequently integrated in the clinical management of fully or partially edentulous patients. It is prudent to realize that despite the high early survival rates, dental implants do have their fair share of long-term esthetic, biological, and mechanical complications. Therefore, this paper aims to review the current evidence on the management of peri-implant diseases in an attempt to answer the following question: Can periimplantitis be treated? Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Macro design morphology of endosseous dental implants.

    PubMed

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  19. Dental-Implantate und ihre Werkstoffe

    NASA Astrophysics Data System (ADS)

    Newesely, Heinrich

    1983-07-01

    Some new trends in materials for dental implants, which also effect in the operative techniques and implant design, are described. Advantages and shortcomings of the different material types are exemplified and correlated with their bioinert resp. bioactive functions. The practical interest in metallic implants focussed in titanium resp. oxide ceramics in the ceramic field, whereas the special goal of implant research follows from the improvement of the bioactive principle with loaded calcium phosphate implants.

  20. Displacement of a dental implant into the maxillary sinus after internal sinus floor elevation: report of a case and review of literature.

    PubMed

    Ding, Xiaojun; Wang, Qing; Guo, Xuehua; Yu, Youcheng

    2015-01-01

    Dental implant placement in the posterior maxilla may be complicated by implant migration into the maxillary sinus. To report the clinical and radiological characteristics of a patient who experienced dental implant displacement into the maxillary sinus following sinus floor elevation, and to compare our findings with those of other published reports of the displacement of dental implants. Implant placement and maxillary sinus elevation were performed simultaneously. The location of the displaced implant was monitored for 8 years, until the ectopic implant was surgically removed using the lateral window approach. The contributing factors, treatment modality, and clinical outcome for our patient were compared with those of patients reported in the literature. The clinical characteristics of our case were similar to those of patients with displaced implants who were also asymptomatic for long periods. The clinical outcome of our case was consistent with that of patients who underwent similar surgeries. Transnasal endoscopic removal of an ectopic implant may be suitable in cases in which the ectopic implant is accessible. Transoral direct approaches are adequate in most cases in which endoscopic approaches may be confounded. The bony-window transoral technique may allow the removal of large implants.

  1. A macro- and nanostructure evaluation of a novel dental implant.

    PubMed

    Tetè, Stefano; Mastrangelo, Filiberto; Traini, Tonino; Vinci, Raffaele; Sammartino, Gilberto; Marenzi, Gaetano; Gherlone, Enrico

    2008-09-01

    Success in implant dentistry also comes from the implant macrodesign and nanostructure of its surface. Titanium implant surface treatments have been shown to enhance osseointegration, maximize bone healing, and bone-to-implant contact for predictable clinical results. The aim of the study, was to evaluate the geometric macrodesign and the surface nanostructure of a novel dental implant full contact covering (FCC) obtained by electrochemical procedures. FCC implants were analyzed by scanning electronic microscope, profilometer, and x-ray photoelectron spectroscopy and compared with commercial sandblasted and sandblasted, large-grit acid-etched dental implants. Sample analysis allowed to distinguish the different implant macrodesigns, the step and the profile of the coils that cover the fixture, and the surface characteristics. FCC implant showed novel macro-characteristic of crestal module, coils, and apical zone compared with sandblasted and sandblasted and acid-etched dental implants. Moreover, the FCC nanostructure surface showed roughness values statistically higher than the 2 other surfaces, with a more homogeneity in a peaks and valleys arrangement. Finally, the x-ray photoelectron spectroscopy analysis detected differences between the examined surfaces, with the presence of several contaminants according to the different treatment procedures. Research on new macrostructures and nano morphology should result in a better qualitative and quantitative osseointegration response, with a predictability of the clinical results and long-term success of the implants.

  2. Capacity of dental equipment to interfere with cardiac implantable electrical devices.

    PubMed

    Lahor-Soler, Eduard; Miranda-Rius, Jaume; Brunet-Llobet, Lluís; Sabaté de la Cruz, Xavier

    2015-06-01

    Patients with cardiac implantable electrical devices should take precautions when exposed to electromagnetic fields. Possible interference as a result of proximity to electromagnets or electricity flow from electronic tools employed in clinical odontology remains controversial. The objective of this study was to examine in vitro the capacity of dental equipment to provoke electromagnetic interference in pacemakers and implantable cardioverter defibrillators. Six electronic dental instruments were tested on three implantable cardioverter defibrillators and three pacemakers from different manufacturers. A simulator model, submerged in physiological saline, with elements that reproduced life-size anatomic structures was used. The instruments were analyzed at differing distances and for different time periods of application. The dental instruments studied displayed significant differences in their capacity to trigger electromagnetic interference. Significant differences in the quantity of registered interference were observed with respect to the variables manufacturer, type of cardiac implant, and application distance but not with the variable time of application. The electronic dental equipment tested at a clinical application distance (20 cm) provoked only slight interference in the pacemakers and implantable cardioverter defibrillators employed, irrespective of manufacturer. © 2015 Eur J Oral Sci.

  3. Genotoxicity of endosseous implants using two cellular lineages in vitro.

    PubMed

    Matsumoto, Mariza; Filho, Hugo Nary; Ferrari, Raquel; Fernandes, Kristianne; Renno, Ana Claudia; Ribeiro, Daniel

    2014-02-01

    The genotoxic potential of corrosion eluates obtained from a single dental implant using murine fibroblasts or osteoblasts cells in vitro by the single-cell gel (comet) assay was examined. A single commercially available dental implant (Biotechnology) was eluted in a solution consisting of equal amounts of acetic acid and sodium chloride (0.1 M) for 1, 3, 7, 14, and 21 days. Murine fibroblast or osteoblast cultures were then exposed to all corrosion eluates obtained from endosseous dental implants for 30 minutes at 37°C. The results suggest that none of the eluates produced genotoxic changes in murine fibroblasts regardless of the length of exposure to the eluate. Similarly, no genotoxicity was found in osteoblasts. The results suggest that the dental implant eluates tested in this study did not induce genetic damage as depicted by the single-cell gel (comet) assay. Because DNA damage is an important event during oncogenesis, this study represents a relevant contribution to estimate the real risks to the cellular system induced by the corrosion products of a dental implant.

  4. Reconstruction of a Severely Atrophied Alveolar Ridge by Computer-Aided Gingival Simulation and 3D-Printed Surgical Guide: A Case Report.

    PubMed

    Song, In-Seok; Lee, Mi-Ran; Ryu, Jae-Jun; Lee, Ui-Lyong

    Dental implants positioned in severely atrophied anterior maxillae require esthetic or functional compromises. This case report describes the rehabilitation of a severely atrophied alveolar ridge with a three-dimensional (3D) computer-aided design/computer-aided manufacture (CAD/CAM) surgical guide. A 50-year-old woman had a severely atrophied anterior maxilla with unfavorably positioned dental implants. Functional and esthetic prosthodontic restoration was difficult to achieve. An anterior segmental osteotomy was planned to reposition the dental implants. A 3D surgical guide was designed for precise relocation of the segment. The surgical guide firmly grasped the impression copings of the dental implants, minimizing surgical errors. Three-dimensional gingival simulation was used preoperatively to estimate the appropriate position of the gingiva. Rigid fixation to the surrounding bone allowed immobilization of the implant-bone segment. Satisfactory esthetic and functional outcomes were attained 6 months after surgery. Finally, a severely atrophied alveolar ridge with unfavorably positioned dental implants was recovered with minimal esthetic and functional deterioration using gingival simulation and a 3D CAD/CAM surgical guide.

  5. Oral Cancer around Dental Implants Appearing in Patients with\\without a History of Oral or Systemic Malignancy: a Systematic Review.

    PubMed

    Pinchasov, Ginnady; Haimov, Haim; Druseikaite, Monika; Pinchasov, Daniel; Astramskaite, Inesa; Sarikov, Rafael; Juodzbalys, Gintaras

    2017-01-01

    The purpose of this article is to systematically review the circumstance of oral cancer around osseointegrated dental implants. An electronic literature search was conducted through the MEDLINE (PubMed) and EMBASE databases. The search was restricted for articles published during the last 21 years from January 1996 to April 2017 and articles were limited to English language. A total of 35 articles were reviewed, and 19 of the most relevant articles that are suitable to the criteria were selected. Case reports were analysed when oral cancer was present in patients with dental implants. Finally, the present data included 28 patients. A direct link between dental implants and oral cancer was not found. It was observed that there were no significant differences in number of incidences of oral cancer between patients with history of malignancy and those without. More research should be made to document such cases. It was noticed that in many cases oral cancer around dental implant present itself as peri-implantitis, correct differential diagnosis is essential in such cases.

  6. Factors influencing treatment decision-making for maintaining or extracting compromised teeth.

    PubMed

    Lang-Hua, Bich Hue; McGrath, Colman P J; Lo, Edward C M; Lang, Niklaus P

    2014-01-01

    To evaluate treatment decision-making with respect to maintaining periodontally compromised teeth among dentists with or without postgraduate qualifications in implant dentistry. A series of patient scenarios with varying degrees of periodontal disease levels was presented to dental practitioners. Practitioners' decision-making outcome was determined, and intention to retain the compromised teeth was analyzed in bivariate and regression analyses (accounting for postgraduate implant training, gender, years in dental practice, and implant placement experience). This study involved 30 dental practitioners with postgraduate implant qualifications (GDPP), 33 dental practitioners without postgraduate implant qualifications (GDP), and 27 practitioners undergoing training for postgraduate implant qualifications (GDPT). Variations in treatment decision-making were evident between the three groups. Differences in treatment approaches to retaining compromised teeth were apparent. Furthermore, variations in rehabilitation of extracted scenarios existed in terms of use of implant and number of implants need for rehabilitation. Accounting for dentist and practice factors in regression analyses, GDPP/GDPT were three times as likely to retain periodontally compromised upper molar, with or without pain, compared to GDP (without pain OR 3.10, 95%CI 1.04, 10.62 P = 0.04; with pain OR 3.08, 95%CI 1.09, 8.14 P = 0.03). Variations in treatment decision-making with respect to retaining periodontally compromised teeth exist between dental practitioners with and those without postgraduate training in implant dentistry. Furthermore differences in management approaches in how they would retain the teeth or rehabilitate the dental arch were apparent. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  7. Dynamic finite element simulation of dental prostheses during chewing using muscle equivalent force and trajectory approaches.

    PubMed

    Razaghi, Reza; Biglari, Hasan; Karimi, Alireza

    2017-05-01

    The long-term application of dental prostheses inside the bone has a narrow relation to its biomechanical performance. Chewing is the most complicated function of a dental implant as it implements different forces to the implant at various directions. Therefore, a suitable holistic modelling of the jaw bone, implant, food, muscles, and their forces would be deemed significant to figure out the durability as well as functionality of a dental implant while chewing. So far, two approaches have been proposed to employ the muscle forces into the Finite Element (FE) models, i.e. Muscle Equivalent Force (MEF) and trajectory. This study aimed at propounding a new three-dimensional dynamic FE model based on two muscle forces modelling approaches in order to investigate the stresses and deformations in the dental prosthesis as well as maxillary bone during the time of chewing a cornflakes bio. The results revealed that both contact and the maximum von Mises stress in the implant and bones for trajectory approach considerably exceed those of the MEF. The maximum stresses, moreover, are located around the neck of implant which should be both clinically and structurally strong enough to functionally maintain the bone-implant interface. In addition, a higher displacement due to compressive load is observed for the implant head in trajectory approach. The results suggest the benefits provided by trajectory approach since MEF approach would significantly underestimate the stresses and deformations in both the dental prosthesis and bones.

  8. Predictable dental rehabilitation in maxillomandibular reconstruction with free flaps. The role of implant guided surgery

    PubMed Central

    Cebrian-Carretero, José L.; Sobrino, José A.; Yu, Tomás; Burgueño-García, Miguel

    2014-01-01

    The reconstruction of maxillomandibular defects secondary to oral cancer surgery, represent a great challenge for Maxillofacial surgeons. During the last decades the reconstructive surgery has experimented a big advance due to the development of the microsurgical techniques. At present, we are able to reconstruct complex defects using free flaps that provide both soft and bone tissue. Fibula, iliac crest and scapula free flaps have been the three classic options for the maxillomandibular reconstruction owing to the amount of bone that this flaps provide, allowing the posterior dental rehabilitation with implants. Today, our objective it is not only the aesthetic reconstruction, but also the functional reconstruction of the patients enhancing their life quality. Guided implant surgery in free flap reconstructed patients has become an essential tool, helping to define the exact position of the dental implant in the flap. In this way it is possible to look for the areas with better bone conditions, avoiding the osteosynthesis material used to fixate the flap with the native bone and deciding the best biomechanical option, in terms of number and situation of the implants, for the future dental prostheses. In summary, using the guided implant surgery, it is possible to design an exact and predictable dental implant rehabilitation in patients with oral cancer who are reconstructed with free microvascular flap, resulting in an optimal aesthetic and functional result. Key words:Oral cancer, mandibulectomy, maxillectomy, microvascular reconstruction, fibula flap, dental implant, guided surgery. PMID:25129241

  9. Effects of Untreated Periodontitis on Osseointegration of Dental Implants in a Beagle Dog Model.

    PubMed

    Lee, Daehyun; Sohn, Byungjin; Kim, Kyoung Hwa; Kim, Sungtae; Koo, Ki-Tae; Kim, Tae-Il; Seol, Yang-Jo; Lee, Yong-Moo; Rhyu, In-Chul; Ku, Young

    2016-10-01

    There have been previous studies on the relationship between periodontitis and peri-implantitis, but limited information is available on how periodontitis affects osseointegration and wound healing of newly placed dental implants adjacent to natural teeth. The objective of the present experiment is to evaluate healing around dental implants adjacent to teeth with untreated experimental periodontitis. The study included six male beagle dogs. Scaling and plaque control procedures were performed on three dogs (control group). In the other three dogs (experimental group), retraction cords and ligature wires were placed subgingivally around all premolars and the first molars. Induced experimental periodontitis was confirmed after 3 months. Each control or experimental group was divided into two subgroups depending on the timing of implant placement (immediate/delayed). Twelve dental implants (two implants for each dog) were placed immediately, and the other 12 dental implants (two implants for each dog) were placed 2 months after extraction. The animals were sacrificed 2 months after implant placement. Histologic and histometric analyses were performed. Four implants (three from the immediate placement group and one from the delayed placement group) failed in the experimental group. There were significant differences in the percentage of bone-to-implant contact and marginal bone volume density between the control and experimental groups. Both parameters were significantly lower in the experimental group than in the control group (P <0.05). There was a tendency toward more marginal bone loss in the experimental group than the control group. Immediate placement of implants is associated with a higher failure rate compared with delayed placement. Untreated experimental periodontitis was correlated with compromised osseointegration in the implants with delayed placement.

  10. Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants.

    PubMed

    Lee, Woo-Taek; Koak, Jai-Young; Lim, Young-Jun; Kim, Seong-Kyun; Kwon, Ho-Beom; Kim, Myung-Joo

    2012-05-01

    The poly-ether-ether-ketone (PEEK) polymer is of great interest as an alternative to titanium in orthopedics because of its biocompatibility and low elastic modulus. This study evaluated the fatigue limits of PEEK and the effects of the low elastic modulus PEEK in relation to existing dental implants. Compressive loading tests were performed with glass fiber-reinforced PEEK (GFR-PEEK), carbon fiber-reinforced PEEK (CFR-PEEK), and titanium rods. Among these tests, GFR-PEEK fatigue tests were performed according to ISO 14801. For the finite element analysis, three-dimensional models of dental implants and bone were constructed. The implants in the test groups were coated with a 0.5-mm thick and 5-mm long PEEK layer on the upper intrabony area. The strain energy densities (SED) were calculated, and the bone resorption was predicted. The fatigue limits of GFR-PEEK were 310 N and were higher than the static compressive strength of GFR-PEEK. The bone around PEEK-coated implants showed higher levels of SED than the bone in direct contact with the implants, and the wider diameter and stiffer implants showed lower levels of SED. The compressive strength of the GFR-PEEK and CFR-PEEK implants ranged within the bite force of the anterior and posterior dentitions, respectively, and the PEEK implants showed adequate fatigue limits for replacing the anterior teeth. Dental implants with PEEK coatings and PEEK implants may reduce stress shielding effects. Dental implant application of PEEK polymer-fatigue limit and stress shielding. Copyright © 2012 Wiley Periodicals, Inc.

  11. Dental implants: A review.

    PubMed

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Evaluation of the Effects of Dental Implants on Oral Lesions.

    PubMed

    Agha-Hosseini, Farzaneh; Rohani, Bita

    2015-05-01

    To determine whether dental implants impress oral lesions, and to evaluate the nature of their effect on the lesions. A comprehensive search was done via Google and PubMed for articles (including case reports and literature reviews) containing the keywords 'oral squamous cell carcinoma' (OSCC), 'oral lichen planus' (OLP), 'lichenoid contact reaction' (LCR), 'osseointegrated implants', and 'dental implants' , in the last 10 years (2002-2012). The study included 24 articles involving patients with dental implants, and some oral lesions (e.g. oral lichen planus and oral squamous cell carcinoma) or with a history of lesions. In these publications, there is evidence suggesting the possibility of emergence, exacerbation, recurrence, or even malignant transformation of the oral lesions after implant placement in some cases. Based on our review of the literature, implant treatment does not seem to be completely safe under any circumstances, but may have some complications in subjects with certain diseases (e.g. oral lesions, autoimmune diseases, malignancies, allergic reactions, etc.). Therefore prior to treatment, patients should be fully informed of the risks. Implant treatment is best done with caution in patients with cancer or mucocutaneous disorders.

  13. The effects of hydroxyapatite coatings on stress distribution near the dental implant bone interface

    NASA Astrophysics Data System (ADS)

    Jiang, W.; Wang, W. D.; Shi, X. H.; Chen, H. Z.; Zou, W.; Guo, Z.; Luo, J. M.; Gu, Z. W.; Zhang, X. D.

    2008-11-01

    The effects of different thickness of hydroxyapatite (HA) coatings on bone stress distribution near the dental implant-bone interface are very important factors for the HA-coated dental implant design and clinical application. By means of finite element analysis (FEA), the bone stress distributions near the dental implant coated with different thicknesses from 0 to 200 μm were calculated and analyzed under the 200 N chewing load. In all cases, the maximal von Mises stresses in the bone are at the positions near the neck of dental implant on the lingual side, and decrease with the increase of the HA coatings thickness. The HA coatings weaken the stress concentration and improve the biomechanical property in the bone, however, in HA coatings thickness range of 60-120 μm, the distinctions of that benefit are not obvious. In addition, considering the technical reason of HA coatings, we conclude that thickness of HA coatings range from 60 to 120 μm would be the better choice for clinical application.

  14. Implant dentistry curriculum in undergraduate education: part 1-a literature review.

    PubMed

    Kroeplin, Birgit S; Strub, Joerg R

    2011-01-01

    The aim of this literature review was to evaluate to what extent oral implant dentistry was integrated into undergraduate educational programs worldwide. An online search of PubMed (MEDLINE and additional life science journals) was performed for articles published from 1966 to January 2010 using combinations of select medical subject headings. Additionally, the ISI Web of Knowledge database (MEDLINE: 1950 to present, Web of Science: 1945 to present) was searched using "education" and "implant" as search terms. The online search was supplemented with a manual search of dental journals in the fields of education, prosthodontics, and implant dentistry and of the reference lists of selected full-text articles. Surveys comparing different undergraduate dental implant curricula and articles describing the undergraduate dental implant curriculum of a single university were identified. Postgraduate or continuing education programs for dental practitioners or master and specialist programs were excluded. Twenty-five articles met the inclusion criteria of this review. The percentage of universities that included implant dentistry in undergraduate education increased from 51% in 1974 to 97% in 2006 for universities in the United States and to 100% for surveyed European universities. All curricula included lectures (mostly 1 to 20 hours) and 30% to 42% included laboratory courses, but the level of clinical experience differed greatly between surveyed universities. Because oral implant dentistry has become a standard treatment alternative, the undergraduate dental curricula should include its application in treatment planning, observation of placing and restoring implants, and treating patients with implant-retained or -supported restorations.

  15. Risk factors for implant failure: a retrospective study in an educational institution using GEE analyses.

    PubMed

    Borba, Marcelo; Deluiz, Daniel; Lourenço, Eduardo José Veras; Oliveira, Luciano; Tannure, Patrícia Nivoloni

    2017-08-21

    This study aimed to evaluate dental implant outcomes and to identify risk factors associated with implant failure over 12 years via dental records of patients attending an educational institution. Dental records of 202 patients receiving 774 dental implants from 2002 to 2014 were analyzed by adopting a more reliable statistical method to evaluate risk factors with patients as the unit [generalized estimating equation (GEE)]. Information regarding patient age at implantation, sex, use of tobacco, and history of systemic diseases was collected. Information about implant location in the arch region and implant length, diameter, and placement in a grafted area was evaluated after 2 years under load. Systemic and local risk factors for early and late implant failure were studied. A total of 18 patients experienced 25 implant failures, resulting in an overall survival rate of 96.8% (2.84% and 0.38% early and late implant failures, respectively). The patient-based survival rate was 91.8%. GEE univariate and multivariate analyses revealed that a significant risk factor for implant failure was the maxillary implant (p = 0.006 and p = 0.014, respectively). Bone grafting appeared to be a risk factor for implant failure (p = 0.054). According to GEE analyses, maxillary implants had significantly worse outcomes in this population and were considered to be a risk factor for implant failure. Our results suggested that implants placed in a bone augmentation area had a tendency to fail.

  16. Polymorphisms of Il-10 (-1082) and RANKL (-438) Genes and the Failure of Dental Implants

    PubMed Central

    Ribeiro, Rodrigo; Melo, Rayanne; Tortamano Neto, Pedro; Vajgel, André

    2017-01-01

    Background. Genetic polymorphisms in certain cytokines and chemokines have been investigated to understand why some individuals display implant flaws despite having few risk factors at the time of implant. Purpose. To investigate the association of genetic polymorphisms in interleukin- (IL-) 10 [-1082 region (A/G)] and RANKL [-438 region (A/G)] with the failure of dental implants. Materials and Methods. This study included 90 partially edentulous male and female patients who were rehabilitated with a total of 245 Straumann dental implants. An implant was considered a failure if any of the following occurred: mobility, persistent subjective complaint, recurrent peri-implant infection with suppuration, continuous radiolucency around the implant, probing depth ≥ 5 mm, and bleeding on probing. Buccal mucosal cells were collected for analysis of RANKL438 and IL-10. Results. The implant success rate in this population was 34.4%. The mutant allele (G) in RANKL had an incidence of 52.3% and mutant allele (A) in IL-10 was observed in 37.8%. No statistically significant difference was detected between the failure of the implant and the genotypes and allelic frequencies. Conclusion. No association was detected between the genetic polymorphisms of RANKL (-438) and IL-10 (-1082) and the failure of dental implants in the population studied. PMID:28348592

  17. Polymorphisms of Il-10 (-1082) and RANKL (-438) Genes and the Failure of Dental Implants.

    PubMed

    Ribeiro, Rodrigo; Melo, Rayanne; Tortamano Neto, Pedro; Vajgel, André; Souza, Paulo Roberto Eleutério; Cimões, Renata

    2017-01-01

    Background . Genetic polymorphisms in certain cytokines and chemokines have been investigated to understand why some individuals display implant flaws despite having few risk factors at the time of implant. Purpose . To investigate the association of genetic polymorphisms in interleukin- (IL-) 10 [-1082 region (A/G)] and RANKL [-438 region (A/G)] with the failure of dental implants. Materials and Methods . This study included 90 partially edentulous male and female patients who were rehabilitated with a total of 245 Straumann dental implants. An implant was considered a failure if any of the following occurred: mobility, persistent subjective complaint, recurrent peri-implant infection with suppuration, continuous radiolucency around the implant, probing depth ≥ 5 mm, and bleeding on probing. Buccal mucosal cells were collected for analysis of RANKL438 and IL-10 . Results . The implant success rate in this population was 34.4%. The mutant allele (G) in RANKL had an incidence of 52.3% and mutant allele (A) in IL-10 was observed in 37.8%. No statistically significant difference was detected between the failure of the implant and the genotypes and allelic frequencies. Conclusion . No association was detected between the genetic polymorphisms of RANKL (-438) and IL-10 (-1082) and the failure of dental implants in the population studied.

  18. The development of a composite bone model for training on placement of dental implants

    PubMed Central

    Alkhodary, Mohamed Ahmed; Abdelraheim, Abdelraheim Emad Eldin; Elsantawy, Abd Elaleem Hassan; Al Dahman, Yousef Hamad; Al-Mershed, Mohammed

    2015-01-01

    Objectives It takes a lot of training on patients for both undergraduate to develop clinical sense as regards to the placement of dental implants in the jaw bones, also, the models provided by the dental implant companies for training are usually made of strengthened synthetic foams, which are far from the composition, and tactile sense provided by natural bone during drilling for clinical placement of dental implants. Methodology This is an in-vitro experimental study which utilized bovine femur bone, where the shaft of the femur provided the surface compact layer, and the head provided the cancellous bone layer, to provide a training model similar to jaw bones macroscopic anatomy. Both the compact and cancellous bone samples were characterized using mechanical compressive testing. Results The elastic moduli of the cancellous and cortical femur bone were comparable to those of the human mandible, and the prepared training model provided a more lifelike condition during the drilling and placement of dental implants. Conclusion The composite bone model developed simulated the macroscopic anatomy of the jaw bones having a surface layer of compact bone, and a core of cancellous bone, and provided a better and a more natural hands-on experience for placement of dental implants as compared to plastic models made of polyurethane. PMID:26309434

  19. The development of a composite bone model for training on placement of dental implants.

    PubMed

    Alkhodary, Mohamed Ahmed; Abdelraheim, Abdelraheim Emad Eldin; Elsantawy, Abd Elaleem Hassan; Al Dahman, Yousef Hamad; Al-Mershed, Mohammed

    2015-04-01

    It takes a lot of training on patients for both undergraduate to develop clinical sense as regards to the placement of dental implants in the jaw bones, also, the models provided by the dental implant companies for training are usually made of strengthened synthetic foams, which are far from the composition, and tactile sense provided by natural bone during drilling for clinical placement of dental implants. This is an in-vitro experimental study which utilized bovine femur bone, where the shaft of the femur provided the surface compact layer, and the head provided the cancellous bone layer, to provide a training model similar to jaw bones macroscopic anatomy. Both the compact and cancellous bone samples were characterized using mechanical compressive testing. The elastic moduli of the cancellous and cortical femur bone were comparable to those of the human mandible, and the prepared training model provided a more lifelike condition during the drilling and placement of dental implants. The composite bone model developed simulated the macroscopic anatomy of the jaw bones having a surface layer of compact bone, and a core of cancellous bone, and provided a better and a more natural hands-on experience for placement of dental implants as compared to plastic models made of polyurethane.

  20. In Vitro Investigation of the Effect of Oral Bacteria in the Surface Oxidation of Dental Implants.

    PubMed

    Sridhar, Sathyanarayanan; Wilson, Thomas G; Palmer, Kelli L; Valderrama, Pilar; Mathew, Mathew T; Prasad, Shalini; Jacobs, Michael; Gindri, Izabelle M; Rodrigues, Danieli C

    2015-10-01

    Bacteria are major contributors to the rising number of dental implant failures. Inflammation secondary to bacterial colonization and bacterial biofilm is a major etiological factor associated with early and late implant failure (peri-implantitis). Even though there is a strong association between bacteria and bacterial biofilm and failure of dental implants, their effect on the surface of implants is yet not clear. To develop and establish an in vitro testing methodology to investigate the effect of early planktonic bacterial colonization on the surface of dental implants for a period of 60 days. Commercial dental implants were immersed in bacterial (Streptococcus mutans in brain-heart infusion broth) and control (broth only) media. Immersion testing was performed for a period of 60 days. During testing, optical density and pH of immersion media were monitored. The implant surface was surveyed with different microscopy techniques post-immersion. Metal ion release in solution was detected with an electrochemical impedance spectroscopy sensor platform called metal ion electrochemical biosensor (MIEB). Bacteria grew in the implant-containing medium and provided a sustained acidic environment. Implants immersed in bacterial culture displayed various corrosion features, including surface discoloration, deformation of rough and smooth interfaces, pitting attack, and severe surface rusting. The surface features were confirmed by microscopic techniques, and metal particle generation was detected by the MIEB. Implant surface oxidation occurred in bacteria-containing medium even at early stages of immersion (2 days). The incremental corrosion resulted in dissolution of metal ions and debris into the testing solution. Dissolution of metal ions and particles in the oral environment can trigger or contribute to the development of peri-implantitis at later stages. © 2015 Wiley Periodicals, Inc.

  1. Factors associated with dental implant survival: a 4-year retrospective analysis.

    PubMed

    Zupnik, Jamie; Kim, Soo-woo; Ravens, Daniel; Karimbux, Nadeem; Guze, Kevin

    2011-10-01

    Dental implants are a predictable treatment option for replacing missing teeth and have strong survival and success outcomes. However, previous research showed a wide array of potential risk factors that may have contributed to dental implant failures. The objectives of this study are to study if implant survival rates were affected by known risk factors and risk indicators that may have contributed to implant failures. The secondary outcome measures were whether the level of expertise of the periodontal residents affected success rates and how the rate of implant success at the Harvard School of Dental Medicine (HSDM) compared to published standards. A retrospective chart review of patients at the HSDM who had one of two types of rough-surface implants (group A or B) placed by periodontology residents from 2003 to 2006 was performed. Demographic, health, and implant data were collected and analyzed by multimodel analyses to determine failure rates and any factors that may have increased the likelihood of an implant failure. The study cohort included 341 dental implants. The odds ratio for an implant failure was most clearly elevated for diabetes (2.59 implant surface group B (7.84), and male groups (4.01). There was no significant difference regarding the resident experience. The success rate for HSDM periodontology residents was 96.48% during the 4-year study period. This study demonstrates that implant success rates at HSDM fell within accepted published standards, confirmed previously identified risk factors for a failure, and potentially suggested that other acknowledged risk factors could be controlled for. Furthermore, the level of experience of the periodontology resident did not have an impact on survival outcomes.

  2. Lasers in oral implantology

    NASA Astrophysics Data System (ADS)

    Arnabat-Domingeuz, Josep

    2016-03-01

    Nowadays the use of implants as a increasing therapy in dentistry and it has become a usual treatment in dental offices. More and more dentists have dental implants included in treatment plans for patients with missing teeth. Therefore is necessary that all dentists know all the possibilities of these treatments. Together with the emergence of dental implants, it is also beginning to see an increase in the onset of lasers in dentistry. These two new techniques in dentistry can be supplemented because as we will see the use of lasers in different cases can improve implant treatment.

  3. 3D Printing/Additive Manufacturing Single Titanium Dental Implants: A Prospective Multicenter Study with 3 Years of Follow-Up

    PubMed Central

    2016-01-01

    This prospective 3-year follow-up clinical study evaluated the survival and success rates of 3DP/AM titanium dental implants to support single implant-supported restorations. After 3 years of loading, clinical, radiographic, and prosthetic parameters were assessed; the implant survival and the implant-crown success were evaluated. Eighty-two patients (44 males, 38 females; age range 26–67 years) were enrolled in the present study. A total of 110 3DP/AM titanium dental implants (65 maxilla, 45 mandible) were installed: 75 in healed alveolar ridges and 35 in postextraction sockets. The prosthetic restorations included 110 single crowns (SCs). After 3 years of loading, six implants failed, for an overall implant survival rate of 94.5%; among the 104 surviving implant-supported restorations, 6 showed complications and were therefore considered unsuccessful, for an implant-crown success of 94.3%. The mean distance between the implant shoulder and the first visible bone-implant contact was 0.75 mm (±0.32) and 0.89 (±0.45) after 1 and 3 years of loading, respectively. 3DP/AM titanium dental implants seem to represent a successful clinical option for the rehabilitation of single-tooth gaps in both jaws, at least until 3-year period. Further, long-term clinical studies are needed to confirm the present results. PMID:27313616

  4. 3D Printing/Additive Manufacturing Single Titanium Dental Implants: A Prospective Multicenter Study with 3 Years of Follow-Up.

    PubMed

    Tunchel, Samy; Blay, Alberto; Kolerman, Roni; Mijiritsky, Eitan; Shibli, Jamil Awad

    2016-01-01

    This prospective 3-year follow-up clinical study evaluated the survival and success rates of 3DP/AM titanium dental implants to support single implant-supported restorations. After 3 years of loading, clinical, radiographic, and prosthetic parameters were assessed; the implant survival and the implant-crown success were evaluated. Eighty-two patients (44 males, 38 females; age range 26-67 years) were enrolled in the present study. A total of 110 3DP/AM titanium dental implants (65 maxilla, 45 mandible) were installed: 75 in healed alveolar ridges and 35 in postextraction sockets. The prosthetic restorations included 110 single crowns (SCs). After 3 years of loading, six implants failed, for an overall implant survival rate of 94.5%; among the 104 surviving implant-supported restorations, 6 showed complications and were therefore considered unsuccessful, for an implant-crown success of 94.3%. The mean distance between the implant shoulder and the first visible bone-implant contact was 0.75 mm (±0.32) and 0.89 (±0.45) after 1 and 3 years of loading, respectively. 3DP/AM titanium dental implants seem to represent a successful clinical option for the rehabilitation of single-tooth gaps in both jaws, at least until 3-year period. Further, long-term clinical studies are needed to confirm the present results.

  5. Survival of dental implants placed in sites of previously failed implants.

    PubMed

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Multifunctions of dual Zn/Mg ion co-implanted titanium on osteogenesis, angiogenesis and bacteria inhibition for dental implants.

    PubMed

    Yu, Yiqiang; Jin, Guodong; Xue, Yang; Wang, Donghui; Liu, Xuanyong; Sun, Jiao

    2017-02-01

    In order to improve the osseointegration and long-term survival of dental implants, it is urgent to develop a multifunctional titanium surface which would simultaneously have osteogeneic, angiogeneic and antibacterial properties. In this study, a potential dental implant material-dual Zn/Mg ion co-implanted titanium (Zn/Mg-PIII) was developed via plasma immersion ion implantation (PIII). The Zn/Mg-PIII surfaces were found to promote initial adhesion and spreading of rat bone marrow mesenchymal stem cells (rBMSCs) via the upregulation of the gene expression of integrin α1 and integrin β1. More importantly, it was revealed that Zn/Mg-PIII could increase Zn 2+ and Mg 2+ concentrations in rBMSCs by promoting the influx of Zn 2+ and Mg 2+ and inhibiting the outflow of Zn 2+ , and then could enhance the transcription of Runx2 and the expression of ALP and OCN. Meanwhile, Mg 2+ ions from Zn/Mg-PIII increased Mg 2+ influx by upregulating the expression of MagT1 transporter in human umbilical vein endothelial cells (HUVECs), and then stimulated the transcription of VEGF and KDR via activation of hypoxia inducing factor (HIF)-1α, thus inducing angiogenesis. In addition to this, it was discovered that zinc in Zn/Mg-PIII had certain inhibitory effects on oral anaerobic bacteria (Pg, Fn and Sm). Finally, the Zn/Mg-PIII implants were implanted in rabbit femurs for 4 and 12weeks with Zn-PIII, Mg-PIII and pure titanium as controls. Micro-CT evaluation, sequential fluorescent labeling, histological analysis and push-out test consistently demonstrated that Zn/Mg-PIII implants exhibit superior capacities for enhancing bone formation, angiogenesis and osseointegration, while consequently increasing the bonding strength at bone-implant interfaces. All these results suggest that due to the multiple functions co-produced by zinc and magnesium, rapid osseointegration and sustained biomechanical stability are enhanced by the novel Zn/Mg-PIII implants, which have the potential application in dental implantation in the future. In order to enhance the rapid osseointegration and long-term survival of dental implants, various works on titanium surface modification have been carried out. However, only improving osteogenic activity of implants is not enough, because angiogenesis and bacteria inhibition are also very important for dental implants. In the present study, a novel dental implant material-dual Zn/Mg ion co-implanted titanium (Zn/Mg-PIII) was developed, which was found to have superior osteoinductivity, pro-angiogenic effects and inhibitory effects against oral anaerobes. Furthermore, synergistic effects of Zn/Mg ions on osteogenic differentiation of rBMSCs and the possible mechanism were discovered. In addition, rapid osseointegration and sustained biomechanical stability are greatly enhanced by Zn/Mg-PIII implants, which may have the potential application in dental implantation in the future. We believe this paper may be of particular interest to the readers. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Impression of multiple implants using photogrammetry: Description of technique and case presentation

    PubMed Central

    Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz

    2014-01-01

    Aim: To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Study Design: Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions – angles and distances – of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient’s mouth using the Sheffield test and the screw resistance test. Results and Conclusions: Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient. Key words:Dental implants, photogrammetry, dental impression technique, CAD/CAM. PMID:24608216

  8. Predoctoral Dental Students' Perceptions of Dental Implant Training: Effect of Preclinical Simulation and Clinical Experience.

    PubMed

    Prasad, Soni; Bansal, Naveen

    2017-04-01

    The aims of this study were to assess 1) differences in perceptions of dental implant training between dental students who received didactic training alone (control group) and those who received didactic plus simulation training (test group); 2) differences in response between students with and without clinical experience in implant dentistry; and 3) the interaction effect of simulation training and clinical experience on students' satisfaction. A survey was distributed to the control group in 2014 and to the test group in 2015; both groups were at the same U.S. dental school. Data were collected on confidence levels with various implant restorative procedures along with overall satisfaction and number of implant restorations performed by each student. The response rate was 78.7% in the control group and 81.3% in the test group. In the control group, 85.7% of students reported being satisfied with implant training compared to 90.8% of students in the test group. The interaction effect of simulation training and clinical experience on overall student satisfaction was OR=1.5 at 95% CI: 0.8, 3.0. The students who had clinical experience with implant restorative procedures had significantly greater satisfaction than those who did not (OR=4.8, 95% CI: 2.1, 11.1, p<0.01). This study found that both the simulation and clinical experience affected these students' confidence and satisfaction levels with implant education: they were almost five times more satisfied with implant training when clinical experience in implant restorative procedures was a part of their implant education.

  9. Dimensional soft tissue changes following soft tissue grafting in conjunction with implant placement or around present dental implants: a systematic review.

    PubMed

    Poskevicius, Lukas; Sidlauskas, Antanas; Galindo-Moreno, Pablo; Juodzbalys, Gintaras

    2017-01-01

    To systematically review changes in mucosal soft tissue thickness and keratinised mucosa width after soft tissue grafting around dental implants. An electronic literature search was conducted of the MEDLINE database published between 2009 and 2014. Sequential screenings at the title, abstract, and full-text levels were performed. Clinical human studies in the English language that had reported changes in soft tissue thickness or keratinised mucosa width after soft tissue grafting at implant placement or around a present implant at 6-month follow-up or longer were included. The search resulted in fourteen articles meeting the inclusion criteria: Six of them reported connective tissue grafting around present dental implants, compared to eight at the time of implant placement. Better long-term soft tissue thickness outcomes were reported for soft tissue augmentation around dental implants (0.8-1.4 mm), compared with augmentation at implant placement (-0.25-1.43 mm). Both techniques were effective in increasing keratinised tissue width: at implant placement (2.5 mm) or around present dental implants (2.33-2.57 mm). The present systematic review discovered that connective tissue grafts enhanced keratinised mucosa width and soft tissue thickness for an observation period of up to 48 months. However, some shrinkage may occur, resulting in decreases in soft tissue, mostly for the first three months. Further investigations using accurate evaluation methods need to be done to evaluate the appropriate time for grafting. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Cost and lack of insurance coverage are prohibitive to having dental implants after resections for benign mandibular neoplasms.

    PubMed

    Peacock, Zachary S; Ji, Yisi D

    2017-06-01

    To assess how often patients receive dental implants after mandibular resection for benign neoplasms and to determine barriers to completion of functional reconstruction. This was a retrospective cohort study of patients who underwent resection for benign mandibular neoplasms between 2005 and 2014. Demographic variables included age, sex, and race. Outcome variables include rates of implant placement, implant restoration, and reasons for not having implants. Fisher's exact test and odds ratios were calculated. In all, 52 subjects (age 47.1 ± 19.2 years) were included. Twenty (38.6%) received dental implants. Race was associated with the likelihood of receiving implants (P = .0302). African Americans (1/11, 9.1%) were least likely compared to all other racial groups to have implants (odds ratio = 0.1158; P = .035; 95% confidence interval 0.013-0.989). Caucasians (17/35, 48.6%) were 4.41 times more likely to receive implants compared to all other races (odds ratio = 4.41; 95% confidence interval 1.073-18.093; P = .038). Of the 20 patients who received implants, 10 went on to have dental prostheses. The most common reason for not having implants was cost (37.5% overall), cited by 50% of black and 16.7% of white patients. Patients do not typically go on to dental reconstruction after mandibular resection, with cost as a major barrier. African Americans were least likely to complete full reconstruction. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Diode Laser and Periodontal Regeneration-Assisted Management of Implant Complications in Anterior Maxilla.

    PubMed

    Salaria, Sanjeev Kumar; Sharma, Isha; Brar, Navjot Kaur; Kaur, Satwant

    2018-01-01

    Dental implant is being considered successful if the patient is pleased with both of its functional and esthetic outcome. As implant complications (such as peri-implantitis, inappropriate implant position, wrong angulation, and implant location too close to anatomical structures) have been frequently encountered in dental practice, therefore, thorough knowledge to manage such complications is the key prerequisite to prevent the failure of implant. The present case report discussed the etiology, diagnosis of early peri-implantitis, and periodontal abscess with their successful management through periodontal regeneration and diode laser-assisted therapy.

  12. Implant failure and history of failed endodontic treatment: A retrospective case-control study.

    PubMed

    Chatzopoulos, Georgios S; Wolff, Larry F

    2017-11-01

    Residual bacterial biofilm and/or bacteria in planktonic form may be survived in the bone following an extraction of an infected tooth that was endodontically treated unsuccessfully Failed endodontic treatment may be associated with failure of implants to osseointegrate in the same sites. Therefore, the aim of this retrospective case-control study is to examine the risk of implant failure in previous failed endodontic sites. This retrospective case-control study is based on 94 dental records of implants placed at the University of Minnesota School of Dentistry. Dental records of patients who received an implant in sites with previously failed endodontic therapy in the dental school were identified from the electronic database, while control subjects were obtained from the same pool of patients with the requirement to have received an implant in a site that was not endodontically treated. The mean age of the population was 62.89±14.17 years with 57.4% of the sample being females and 42.6% of them being males. In regards to the socio-economic status and dental insurance, 84.0% of this population was classified as low socio-economic status and 68.1% had dental insurance. Tobacco use was self-reported by 9.6% and hypercholesterolemia was the most prevalent systemic medical condition. Dental implant failure was identified in two of the included records (2.1%), both of which were placed in sites with a history of failed endodontic treatment. Within the limitations of this retrospective case-control study, further investigation with a larger population group into implant failure of sites that previously had unsuccessful endodontic treatment would be warranted. Implant failure may be associated with a history of failed endodontic treatment. Key words: Implantology, endodontics, osseointegration, treatment outcome, case-control study.

  13. Crestal bone loss around submerged and nonsubmerged dental implants: A systematic review.

    PubMed

    Al Amri, Mohammad D

    2016-05-01

    To my knowledge, there is no systematic review of crestal bone loss (CBL) around submerged and nonsubmerged dental implants. The purpose of this review was to systematically assess CBL around submerged and nonsubmerged dental implants. The addressed focused question was, "Does crestal and subcrestal placement of dental implants influence crestal bone levels?" Databases were searched from 1986 through October 2015 using different combinations of the following keywords: crestal, sub-crestal, bone loss, dental implant, submerged, and nonsubmerged. Reference lists of potentially relevant original and review articles were hand-searched to identify any further studies. Letters to the editor, case reports, commentaries, studies on platform-switched implants, and studies published in languages other than English were excluded. In total, 13 studies (6 human and 7 animal), which were performed at universities, were included. In the human studies, the number of participants ranged from 8 to 84 individuals. The follow-up period ranged from 1 to 5 years. CBL at the test sites ranged from 0.17 mm to 0.9 mm and at control sites from 0.02 mm to 1.4 mm. Five human studies reported no significant difference in CBL around implants placed at the test and control sites. All animal studies were performed in dogs with a mean age ranging from 1 to approximately 2 years. The follow-up period ranged from 2 to 6 months. Four animal studies reported no significant difference in CBL around submerged and nonsubmerged implants. No significant difference in CBL was found around submerged and nonsubmerged dental implants. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Reconstruction of the maxilla following hemimaxillectomy defects with scapular tip grafts and dental implants.

    PubMed

    Mertens, Christian; Freudlsperger, Christian; Bodem, Jens; Engel, Michael; Hoffmann, Jürgen; Freier, Kolja

    2016-11-01

    Treatment of post-resective defects of the maxilla can be challenging and usually requires dental obturation or microvascular reconstruction. As compared to soft-tissue microvascular grafts, bone reconstruction can additionally allow for facial support and retention of dental implants. The aim of this study was to evaluate scapular tip grafts with respect to their applicability for maxillary reconstruction and their potential to retain dental implants for later dental rehabilitation. In this retrospective study, 14 patients with hemimaxillectomy defects were reconstructed with free scapular tip grafts, oriented horizontally, to rebuild the palate and alveolar ridge. After bone healing, three-dimensional virtual implant planning was performed, and a radiographic guide was fabricated to enable implant placement in the optimal anatomic and prosthetic position. All patients' mastication and speech were evaluated, along with the extent of defect closure, suitability of the graft sites for implant placement, and soft-tissue stability. Pre- and postsurgical radiographs were also evaluated. A good postoperative outcome was achieved in all patients, with complete closure of maxillary defects that were class II, according to the system of Brown and Shaw. Additional bone augmentation was necessary in two patients in order to increase vertical bone height. Patients were subsequently treated with 50 dental implants to retain dental prostheses. In all cases, additional soft-tissue surgery was necessary to achieve a long-term stable periimplant situation. No implants were lost during the mean observation period of 34 months. Due to its specific form, the scapular tip graft is well suited to reconstruct the palate and maxillary alveolar ridge and to enable subsequent implant-retained rehabilitation. Due to the limited bone volume, an accurate three-dimensional graft orientation is essential. Furthermore, most cases require additional soft-tissue surgery to achieve a long-term stable periimplant situation. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Patients' experiences of dental implant treatment: A literature review of key qualitative studies.

    PubMed

    Kashbour, W A; Rousseau, N S; Ellis, J S; Thomason, J M

    2015-07-01

    To identify and summarise the findings of previous qualitative studies relating to patients' experience of dental implant treatment (DIT) at various stages of their implant treatment, by means of textual narrative synthesis. Original articles reporting patients' experience with dental implant were included. A two-stage search of the literature, electronic and hand search identified relevant qualitative studies up to July 2014. An extensive electronic search was conducted of databases including PubMed, Embase, Scopus, Web of Knowledge, Cochrane Database and Google Scholar. Included primary studies (n=10) used qualitative research methods and qualitative analysis to investigate patients' experiences with dental implants treatment. While the growing interest in implant treatment for the replacement of missing dentition is evident, it is essential to investigate patients' perceptions of different aspects of implant treatment. This textual narrative synthesis conducted to review qualitative studies which provided insight into patients' experience of two types of implant prostheses namely ISOD (implant-supported overdenture) and FISP (fixed implant supported prostheses). Primary reviewed studies tended to include samples of older patients with more extensive tooth loss, and to focus on experiences prior to and post-treatment rather than on the treatment period itself. Findings across reviewed studies (n=10) suggested that patients with FISP thought of implant treatment as a process of 'normalisation'(1) and believed that such implant restorations could be similar to natural teeth, whereas patients with ISOD focused more on the functional and social advantages of their implant treatment. The growing interest in qualitative research is evident in several branches of clinical dentistry and dental implantology is not an exception. Qualitative studies concerning the patients account of their experience of dental implants is however limited. The aim of this review is to firstly identify recent work within this field and to subsequently categorise it more consistently by means of textural narrative synthesis, thus highlighting similarities and differences and enabling identification of gaps in research knowledge thereby setting the direction of further research. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Cytocompatibility, cytotoxicity and genotoxicity analysis of dental implants

    NASA Astrophysics Data System (ADS)

    Reigosa, M.; Labarta, V.; Molinari, G.; Bernales, D.

    2007-11-01

    Several types of materials are frequently used for dental prostheses in dental medicine. Different treatments with titanium are the most used. The aim of the present study was to analyze by means of cytotoxicity and cytocompatibility techniques the capacity of dental implants to integrate to the bone tissue. Cultures of UMR 106 cell line derived from an osteosarcoma were used for bioassays mainly because they show many of the properties of osteoblasts. Dental implant samples provided by B&W company were compared with others of recognized trademarks. The first ones contain ASTM titanium (8348 GR2) with acid printing. Cytotoxicity was analyzed by means of lysosome activity, using the neutral red technique and alkaline phosphatase enzyme activity. Cell variability was determined by means of the acridine ethidium-orange bromide technique. One-way ANOVA and Bonferroni and Duncan post-ANOVA tests were used for the statistical analysis. The assays did not show significant differences among the dental implants analyzed. Our findings show that the dental prostheses studied present high biocompatibility, quantified by the bioassays performed. The techniques employed revealed that they can be a useful tool for the analysis of other materials for dental medicine use.

  17. Management of dental implant fractures. A case history.

    PubMed

    Al Quran, Firas A M; Rashan, Bashar A; Al-Dwairi, Ziad N

    2009-01-01

    The widespread use of endosseous osseointegrated implants to replace missing natural teeth increases the chances of implant complications and failures, despite the high initial success rate reported in the literature. Implant fracture is one possible complication that results in ultimate failure of the dental implant. Such a complication poses a management crisis even for the most experienced clinician. This article reports on a case of implant fracture, its possible causes, and how the case was managed.

  18. Incidence of Prosthetic Complications associated with Implant-borne Prosthesis in a Sleep Disorder Center.

    PubMed

    Suneel, Venkatesh B; Kotian, Santhosh; Jujare, Ravikanth H; Shetty, Adarsh K; Nidhi, Sneh; Grover, Shehkar

    2017-09-01

    Obstructive sleep apnea (OSA) is one of the common prevalent conditions present worldwide. The process of abnormal habits related to clenching and grinding of teeth is referred to as bruxism and is characterized under the heading of parafunctional activity of the masticatory system. Osseointegrated dental implants represent advancements in the field of odontology. Despite its high success rate, failure and complications are often associated with dental implant treatment due to a number of factors. Hence, we aimed for the present study to assess the incidence of prosthetic complications in patients rehabilitated with implant-borne prosthesis in a sleep disorder unit. The present study included the assessment of all the patients who underwent prosthetic rehabilitation by dental implants. An experienced registered prosthodontist was given duty for examination of all the cases from the record file data. Prosthetic complications in the patients were identified using photographs, radiographs, and all other relevant data of the patients obtained from the record files. All types of complications and other factors were recorded separately and analyzed. While correlating the prosthetic complications in OSA patients grouped based on number of dental implants, nonsignificant results were obtained. Significant correlation was observed while comparing the prosthetic complications divided based on type of prosthesis. Fracture of the porcelain was observed in four and eight cases respectively, of screwed and cemented dental implant cases. Some amount of significant correlation existed between the incidences of prosthetic complications and OSA. Proper history of the patients undergoing dental implant procedures should be taken to avoid failure.

  19. Success of dental implants in vascularised fibular osteoseptocutaneous flaps used as onlay grafts after marginal mandibulectomy.

    PubMed

    Chang, Y-M; Pan, Y-H; Shen, Y-F; Chen, J-K; ALDeek, N F; Wei, F-C

    2016-12-01

    We have evaluated the survival of dental implants placed in vascularised fibular flap onlay grafts placed over marginal mandibulectomies and the effects on marginal bone loss of different types of soft tissue around implants under functional loading. From 2001-2009 we studied a total of 11 patients (1 woman and10 men), three of whom had had ameloblastoma and eight who had had squamous cell carcinomas resected. A total of 38 dental implants were placed either at the time of transfer of the vascularised fibular ostoseptocutaneous flaps (nine patients with 30 implants) or secondarily (two patients with eight implants). Four patients were given palatal mucosal grafts to replace intraoral skin flaps around the dental implants (n=13), and the other seven had the skin flaps around the dental implants thinned (n=25) at the second stage of implantation of the osteointegrated teeth. All vascularised fibular osteoseptocutaneous flaps were successfully transferred, and all implants survived a mean (range) of 73 (33-113) months after occlusal functional loading. The mean (SD) marginal bone loss was 0.5 (0.3) mm on both mesial and distal sides in patients who had palatal mucosal grafts, but 1.8 (1.6) mm, and 1.7 (1.5) mm, respectively, on the mesial and distal sides in the patients who had had thinning of their skin flaps. This difference is significant (p=0.008) with less resorption of bone in the group who had palatal mucosal grafts. Palatal mucosa around the implants helps to reduce resorption of bone after functional loading of implants. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1977-11-01

    assisted by Mr. Larry G. McCoy, We are gratefully indebted to our dental consultants from The Ohio State University , College of Dentistry: Dr...SURGICAL TOOTH IMPLANTS , COMBAT AND FIELD by Craig R. Hassler and Larry G. McCoy BACKGROUND Research interest in dental restorations has continued...terman, R.B., and Marshall , R.P. , “ Dental Anchors of Non-Natural Design Implanted In Miniature Swine ” , J. Dent. Res., 52, 124 (1973). (11) Mills

  1. Retrospective analysis of dental implants placed and restored by advanced prosthodontic residents.

    PubMed

    Barias, Pamela A; Lee, Damian J; Yuan, Judy Chia-Chun; Sukotjo, Cortino; Campbell, Stephen D; Knoernschild, Kent L

    2013-02-01

    The purposes of this retrospective clinical review were to: (1) describe the demographics of implant patients, types of implant treatment and implant-supported prostheses in an Advanced Education in Prosthodontic Program, (2) evaluate the survival rate of dental implants placed by prosthodontic residents from 2006 to 2008, and (3) analyze the relationship between resident year of training and implant survival rate. All patients who received dental implants placed by prosthodontic residents from January 2006 to October of 2008 in the Advanced Prosthodontic Program at the University of Illinois at Chicago College of Dentistry were selected for this study. Age, gender, implant diameter, length, implant locations, surgical and restorative detail, and year of prosthodontic residency training were collected and analyzed. Life-table and Kaplan-Meier survival analyses were performed based on implants overall, locations, year of training, and use of a computer-generated surgical guide. A Logrank statistic was performed between implant survival and year of prosthodontic residency training, location, and use of computer-generated surgical guide (α= 0.05). Three hundred and six implants were placed, and of these, seven failed. Life-table and Kaplan-Meier analyses computed a cumulative survival rate (CSR) of 97% for overall implants and implants placed with a computer-generated surgical guide. No statistical difference was found in implant survival rates as a function of year of training (P= 0.85). Dental implants placed by prosthodontic residents had a CSR comparable to previously published studies by other specialties. The year of prosthodontic residency training and implant failure rate did not have any significant relationship. © 2012 by the American College of Prosthodontists.

  2. SU-E-T-492: The Dosimetric and Clinical Impact of the Metallic Dental Implants on Radiation Dose Distributions in IMRT Head and Neck Cancer Patients.

    PubMed

    Wang, L; Xing, L; Le, Q

    2012-06-01

    In H&N cancer patients, the development of oral mucositis is related closely to the radiation dose to the oral cavity. It is generally presumed that the existence of metallic dental implants makes it worse due to the scattering effect of the metal. This study investigates the effects of the dental implants on radiation doses to PTV, tongue mucosa, and other structures for IMRT H&N cancer patients by Monte Carlo (MC) dose calculations. Two H&N cancer patients who have dental implant and are treated by IMRT technique are selected for the purpose. The BEAMnrc/DOSXYZnrc MC codes are employed for the CT-image based dose calculations. The radiation sources are the validated Varian phase-space files for 6MV linac beams. The CT image artifacts caused by the dental fillings are replaced by tissue material. Two sets of MC calculations for each patient are performed at a calculation statistics of 1%: one treats all dental implants as bones, the other substitutes the implants by metal of either titanium or gold with correct density. Doses in PTV and various tissue structures are compared for the two scenarios. With titanium implant, there is no significant difference in doses to PTV and tongue mucosa from that when treating implant as bone. With gold implant, the mean dose to PTV is slightly lowered by 1%; the mean dose to tongue mucosa is reduced by less than 0.5%, although the maximum dose is increased by 5%. The scattering dose from titanium implants is not of concern for H&N patients irradiated by 6MV IMRT beams. For gold implants, the scattering dose to tongue mucosa is not as severe as presumed; and the dose to PTV could be slightly compromised due to the attenuation effect of the metal. This work was supported in part by Varian Medical Systems. © 2012 American Association of Physicists in Medicine.

  3. [A clinical investigation of new patients who had already received treatment with dental implants at other clinics in seventeen years].

    PubMed

    Yukawa, Ken; Tachikawa, Noriko; Munakata, Motohiro; Shiota, Makoto; Kasugai, Shohei

    2014-03-01

    The purpose of this study was to investigate new patients who had already received treatment with dental implants. The subjects were patients who visited the clinic for oral implants at Tokyo Medical and Dental University Hospital from April 1995 to March 2012. The results were as follows: 1) Of the total number of patients, there were 2,419 patients (14.0%) with dental implants. 2) Of the 2,419 patients, 252 patients (10.4%) had been referred from operating doctors or operating clinics. 3) There were 1,516 (62.7%) patients with complaints related to the implant therapy. 4) There were 1,367 (56.5%) patients who had ill feelings toward their attending doctors. 5) There were 1,112 (46.0%) patients with biological complications. 6) Regarding patients with or without a referral from the doctor who had performed their dental implant, those patients who had been referred showed significantly higher occurrence of loss of implants, neurological symptoms, doctor's recommendation, prosthetic problems, and surgical problems. Almost implant therapies were treated with other treatments for natural teeth, including surgical treatment, prosthetic treatment, periodontal treatment and maintenance. These were too complex to enable the results to be forecast before treatment, therefore unpredictable symptoms often occur in patients with implant therapy. Informed consent including patient education is important, but the results of this study suggest that it is insufficient at present.

  4. Optimum gradient material for a functionally graded dental implant using metaheuristic algorithms.

    PubMed

    Sadollah, Ali; Bahreininejad, Ardeshir

    2011-10-01

    Despite dental implantation being a great success, one of the key issues facing it is a mismatch of mechanical properties between engineered and native biomaterials, which makes osseointegration and bone remodeling problematical. Functionally graded material (FGM) has been proposed as a potential upgrade to some conventional implant materials such as titanium for selection in prosthetic dentistry. The idea of an FGM dental implant is that the property would vary in a certain pattern to match the biomechanical characteristics required at different regions in the hosting bone. However, matching the properties does not necessarily guarantee the best osseointegration and bone remodeling. Little existing research has been reported on developing an optimal design of an FGM dental implant for promoting long-term success. Based upon remodeling results, metaheuristic algorithms such as the genetic algorithms (GAs) and simulated annealing (SA) have been adopted to develop a multi-objective optimal design for FGM implantation design. The results are compared with those in literature. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Functional tooth restoration by next-generation bio-hybrid implant as a bio-hybrid artificial organ replacement therapy

    PubMed Central

    Oshima, Masamitsu; Inoue, Kaoru; Nakajima, Kei; Tachikawa, Tetsuhiko; Yamazaki, Hiromichi; Isobe, Tomohide; Sugawara, Ayaka; Ogawa, Miho; Tanaka, Chie; Saito, Masahiro; Kasugai, Shohei; Takano-Yamamoto, Teruko; Inoue, Takashi; Tezuka, Katsunari; Kuboki, Takuo; Yamaguchi, Akira; Tsuji, Takashi

    2014-01-01

    Bio-hybrid artificial organs are an attractive concept to restore organ function through precise biological cooperation with surrounding tissues in vivo. However, in bio-hybrid artificial organs, an artificial organ with fibrous connective tissues, including muscles, tendons and ligaments, has not been developed. Here, we have enveloped with embryonic dental follicle tissue around a HA-coated dental implant, and transplanted into the lower first molar region of a murine tooth-loss model. We successfully developed a novel fibrous connected tooth implant using a HA-coated dental implant and dental follicle stem cells as a bio-hybrid organ. This bio-hybrid implant restored physiological functions, including bone remodelling, regeneration of severe bone-defect and responsiveness to noxious stimuli, through regeneration with periodontal tissues, such as periodontal ligament and cementum. Thus, this study represents the potential for a next-generation bio-hybrid implant for tooth loss as a future bio-hybrid artificial organ replacement therapy. PMID:25116435

  6. Comparison of Results of Measurement of Dimensions of the Placed Dental Implants on Cone Beam Computed Tomography with Dimensions of the Producers of the Implants.

    PubMed

    Repesa, Merisa; Sofic, Amela; Jakupovic, Selma; Tosum, Selma; Kazazic, Lejla; Dervisevic, Almir

    2017-06-01

    One of the most frequently used method for scanning patients with indication for dental implantation in dentistry is cone beam computed tomography. Implantation, CBCT imaging and implant programme are inevitable when planning a successful replacement of lost teeth. CBCT offers exact information about available bone and its density, adjacent tooth roots, the place of mandibular canal and maxillary sinus and adjacent anatomical structure. The goal of this study is to estimate accuracy of measurements on CBCT images ofpatients who have implants of different producers and determine if there is any statistically significant correlation between four test groups regardless of the alloy of which implants are made. The study was a prospective-comparative, and included fifteen patients with hundred dental implants divided in four groups depending on the producer. Over dimensioning in the gained measurements of the whole sample on CBCT images in relation to dimensions of producers is between 0.1006mm and 0.368mm. Even though over dimensioning is measured in millimetres, it has to be taken into consideration in clinical practice when planning an implant placement, and we can recommend safety zone of 0.5mm. There have been no statistically significant differences in the gained results in over dimensioning of implants of different alloys for horizontal and vertical measurements on CBCT images of Astra Tech, Brendet titanium implants and Straumann titanium-zirconium implants. Based on the goals of the study there have been confirmed statistically significant correlations of great value (from 0.841 to 0.936) of high level of importance between manufactured value of dimensions and average dimensions values gained through CBCT imaging in four types of implants (four test groups). The total exactness of measurements on CBCT scan in this research is 96.66% for horizontal measuring and 96.92% for vertical measuring. Therefore, we can conclude that CBCT as radiological method has an unavoidable importance in planning and successful realisation of dental implant procedure. Cone Beam Computed Tomography provides exact measurements of dimensions of placed dental implant in relation to dimensions of the producers of the implant because the material from which dental implants have been made does not significantly affect the precision of the measurement.

  7. Measurement of clinicians' ability to hand torque dental implant components.

    PubMed

    Kanawati, Ali; Richards, Mark W; Becker, Jeffery J; Monaco, Natalie E

    2009-01-01

    There is a varying degree of hand torque abilities using finger drivers among clinicians. Calibrating one's own abilities requires complicated instruments not readily available. This study evaluated a simple-to-use method that allows dental practitioners to have a quantifiable clinical assessment of relative torque ability using finger drivers to torque down dental implant components. A typodont that includes dental implants was mounted in a mannequin placed in a patient-reclined position. The subjects were asked to torque as tightly as they could a new healing abutment to an implant secured firmly in resin within the typodont. All participants wore moistened gloves when using a finger driver. The healing abutment was countertorqued using a certified precalibrated precision torque measurement device. The reading on the torque driver was recorded when the healing abutment disengaged. An average of torque values of dentists and dental students was calculated. Fifty subjects had an average maximum torque ability of 24 Ncm (male dentists: 28 Ncm; students: 22 Ncm; male students: 24 Ncm; female students: 19 Ncm). Maximum torque values for all participants ranged from 11 Ncm to 38 Ncm. There was no significant difference between groups. This study showed a varying degree of hand torquing abilities using a finger driver. Clinicians should regularly calibrate their ability to torque implant components to more predictably perform implant dentistry. Dental implant manufacturers should more precisely instruct clinicians as to maximum torque, as opposed to "finger tighten only".

  8. Numerical study of effect of elastomeric stress absorbers on stress reduction in bone-dental implant interface.

    PubMed

    Mehdi, Ghalem; Belarbi, Abderrahmane; Mansouri, Bensmaine; Azari, Zitouni

    2015-01-01

    This paper focused on optimal stress distribution in the mandibular bone surrounding a dental implant and is devoted to the development of a modified Osteoplant® implant type in order to minimize stress concentration in the bone-implant interface. This study investigated 0.4 mm thick layers of two elastomeric stress barriers incorporated into the dental implant using 3-D finite element analysis. Overall, this proposed implant provoked lower load transfer in bone-implant interface due to the effect of the elastomers as stress absorbers. The stress level in the bone was reduced between 28% and 42% for three load cases: 75 N, 60 N and 27 N in corono-apical, linguo-buccal and disto-mesial direction, respectively. The proposed model provided an acceptable solution for load transfer reduction to the mandible. This investigation also permitted to choose how to incorporate two elastomers into the Osteoplant® implant system.

  9. Research on dental implant and its industrialization stage

    NASA Astrophysics Data System (ADS)

    Dongjoon, Yang; Sukyoung, Kim

    2017-02-01

    Bone cell attachment to Ti implant surfaces is the most concerned issue in the clinical implant dentistry. Many attempts to achieve the fast and strong integration between bone and implant have been tried in many ways, such as selection of materials (for example, Ti, ZrO2), shape design of implant (for example, soft tissue level, bone level, taped or conical, etc), and surface modification of implants (for example, roughed. coated, hybrid), etc. Among them, a major consideration is the surface design of dental implants. The surface with proper structural characteristics promotes or induces the desirable responses of cells and tissues. To obtain such surface which has desirable cell and tissue response, a variety of surface modification techniques has been developed and employed for many years. In this review, the method and trend of surface modification will be introduced and explained in terms of the surface topography and chemistry of dental implants.

  10. Implant Education Programs in North American Dental Schools.

    ERIC Educational Resources Information Center

    Arbree, Nancy S.; Chapman, Robert J.

    1991-01-01

    A survey of 52 dental schools found that dental implant techniques were taught in 34 pre- and 34 postdoctoral curricula, involving mostly prosthodontics and oral surgery departments, with periodontology departments lagging behind. Most predoctoral programs did not have research involvement. Cooperation among specialties is recommended over implant…

  11. A contrast and registration template for magnetic resonance image data guided dental implant placement

    NASA Astrophysics Data System (ADS)

    Eggers, Georg; Cosgarea, Raluca; Rieker, Marcus; Kress, Bodo; Dickhaus, Hartmut; Mühling, Joachim

    2009-02-01

    An oral imaging template was developed to address the shortcomings of MR image data for image guided dental implant planning and placement. The template was conctructed as a gadolinium filled plastic shell to give contrast to the dentition and also to be accurately re-attachable for use in image guided dental implant placement. The result of segmentation and modelling of the dentition from MR Image data with the template was compared to plaster casts of the dentition. In a phantom study dental implant placement was performed based on MR image data. MR imaging with the contrast template allowed complete representation of the existing dentition. In the phantom study, a commercially available system for image guided dental implant placement was used. Transformation of the imaging contrast template into a surgical drill guide based on the MR image data resulted in pilot burr hole placement with an accuracy of 2 mm. MRI based imaging of the existing dentition for proper image guided planning is possible with the proposed template. Using the image data and the template resulted in less accurate pilot burr hole placement in comparison to CT-based image guided implant placement.

  12. Advances in surfaces and osseointegration in implantology. Biomimetic surfaces

    PubMed Central

    Albertini, Matteo; Fernandez-Yague, Marc; Lázaro, Pedro; Herrero-Climent, Mariano; Bullon, Pedro; Gil, Francisco-Javier

    2015-01-01

    The present work is a revision of the processes occurring in osseointegration of titanium dental implants according to different types of surfaces -namely, polished surfaces, rough surfaces obtained from subtraction methods, as well as the new hydroxyapatite biomimetic surfaces obtained from thermochemical processes. Hydroxyapatite’s high plasma-projection temperatures have proven to prevent the formation of crystalline apatite on the titanium dental implant, but lead to the formation of amorphous calcium phosphate (i.e., with no crystal structure) instead. This layer produce some osseointegration yet the calcium phosphate layer will eventually dissolve and leave a gap between the bone and the dental implant, thus leading to osseointegration failure due to bacterial colonization. A new surface -recently obtained by thermochemical processes- produces, by crystallization, a layer of apatite with the same mineral content as human bone that is chemically bonded to the titanium surface. Osseointegration speed was tested by means of minipigs, showing bone formation after 3 to 4 weeks, with the security that a dental implant can be loaded. This surface can be an excellent candidate for immediate or early loading procedures. Key words:Dental implants, implants surfaces, osseointegration, biomimetics surfaces. PMID:25662555

  13. Bruxism and Dental Implants: A Meta-Analysis.

    PubMed

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-10-01

    To test the null hypothesis of no difference in the implant failure rates, postoperative infection, and marginal bone loss after the insertion of dental implants in bruxers compared with the insertion in non-bruxers against the alternative hypothesis of a difference. An electronic search was undertaken in June 2014. Eligibility criteria included clinical studies, either randomized or not. Ten publications were included with a total of 760 implants inserted in bruxers (49 failures; 6.45%) and 2989 in non-bruxers (109 failures; 3.65%). Due to lack of information, meta-analyses for the outcomes "postoperative infection" and "marginal bone loss" were not possible. A risk ratio of 2.93 was found (95% confidence interval, 1.48-5.81; P = 0.002). These results cannot suggest that the insertion of dental implants in bruxers affects the implant failure rates due to a limited number of published studies, all characterized by a low level of specificity, and most of them deal with a limited number of cases without a control group. Therefore, the real effect of bruxing habits on the osseointegration and survival of endosteal dental implants is still not well established.

  14. Evaluation of marginal bone loss of dental implants with internal or external connections and its association with other variables: A systematic review.

    PubMed

    de Medeiros, Rodrigo Antonio; Pellizzer, Eduardo Piza; Vechiato Filho, Aljomar José; Dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas; Goiato, Marcelo Coelho

    2016-10-01

    Different factors can influence marginal bone loss around dental implants, including the type of internal and external connection between the implant and the abutment. The evidence needed to evaluate these factors is unclear. The purpose of this systematic review was to evaluate marginal bone loss by radiographic analysis around dental implants with internal or external connections. A systematic review was conducted following the criteria defined by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Initially, a population, intervention, comparison, and outcome(s) (PICO) question was defined: does the connection type (internal or external) influence marginal bone loss in patients undergoing implantation? An electronic search of PubMed/MEDLINE and Scopus databases was performed for studies in English language published between January 2000 and December 2014 by 2 independent reviewers, who analyzed the marginal bone loss of dental implants with an internal and/or external connection. From an initial screening yield of 595 references and after considering inclusion and exclusion criteria, 17 articles were selected for this review. Among them, 10 studies compared groups of implants with internal and external connections; 1 study evaluated external connections; and 6 studies analyzed internal connections. A total of 2708 implants were placed in 864 patients. Regarding the connection type, 2347 implants had internal connections, and 361 implants had external connections. Most studies showed lower marginal bone loss values for internal connection implants than for external connection implants. Osseointegrated dental implants with internal connections exhibited lower marginal bone loss than implants with external connections. This finding is mainly the result of the platform switching concept, which is more frequently found in implants with internal connections. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Influence of immediate loading on provisional restoration in dental implant stability

    NASA Astrophysics Data System (ADS)

    Ikbal, M.; Odang, R. W.; Indrasari, M.; Dewi, R. S.

    2017-08-01

    The success of dental implant treatment is determined by the primary stability at placement. One factor that could influence this stability is occlusal loading through provisional restoration. Two types of loading protocols are usually used: immediate and delayed loading. However, some controversies remain about the influence of occlusal loading on implant stability. Therefore, the influence of immediate loading on implant stability must be studied. An animal study was conducted by placing nine dental implants in the mandibular jaw of three Macaca fascicularis. Provisional restorations with various occlusal contacts (no, light, and normal contact) were placed on the implant. The implant stability was measured using the Ostell ISQ three times: immediately (baseline) and at the first and second months after implant placement. The implant stability between implants with no and normal occlusal contact as well as light and normal occlusal contact showed significant differences (p < 0.05) at the first and second months after implant placement. However, no significant increase (p > 0.05) in implant stability was seen at the baseline and the first and second months after implant placement for all occlusal contact groups. Immediate loading influenced the implant stability, and provisional restoration of implant without occlusal contact showed the highest implant stability.

  16. Characterization of the Correct Mandibular Premolar Region for Delayed Dental Implantation in Beagle Dogs.

    PubMed

    Xie, Chenxi; Fu, Xiaoming; Xu, Ling; Xu, Sheng

    2018-05-01

    For delayed dental implantation into the mandible, the implant size should be chosen according to the characteristics of that bone. This study investigated anatomic features of the mandible in beagle dogs, to develop recommendations regarding the correct implantation region and available bone area for delayed dental implantation surgery. We used 20 healthy male beagle dogs to create delayed dental implantation models. The dogs' mandibles underwent cone beam CT (CBCT) imaging; the locations of the middle mental foramen and canine root apex were measured on CBCT images. The dogs then were euthanized and their mandibles measured by using a digital vernier caliper. In addition, the correct implantation region and available bone areas were evaluated. The data obtained by using the 2 measuring methods were compared statistically. The results showed that the positions of the middle mental foramen and canine root apex were relatively fixed, with little variation. The implantation and available bone regions showed little variation among dogs and did not differ significantly between the 2 measuring methods. In conclusion, the correct implantation region (mean ± 1 SD) in the beagle mandible for delayed dental implantation surgery was 17.53 ± 0.46 mm in width. The recommended available bone areas (height × width) were 7.22 ± 0.68 mm × 5.32 ± 0.49 mm (P2), 8.21 ± 0.71 mm × 5.81 ± 0.56 mm (P3), and 9.17 ± 0.65 mm × 6.39 ± 0.56 mm (P4) in the premolar region.

  17. Effect of Macrogeometry on the Surface Topography of Dental Implants.

    PubMed

    Naves, Marina Melo; Menezes, Helder Henrique Machado; Magalhães, Denildo; Ferreira, Jessica Afonso; Ribeiro, Sara Ferreira; de Mello, José Daniel Biasoli; Costa, Henara Lillian

    2015-01-01

    Because the microtopography of titanium implants influences the biomaterial-tissue interaction, surface microtexturing treatments are frequently used for dental implants. However, surface treatment alone may not determine the final microtopography of a dental implant, which can also be influenced by the implant macrogeometry. This work analyzed the effects on surface roughness parameters of the same treatment applied by the same manufacturer to implants with differing macro-designs. Three groups of titanium implants with different macro-designs were investigated using laser interferometry and scanning electron microscopy. Relevant surface roughness parameters were calculated for different regions of each implant. Two flat disks (treated and untreated) were also investigated for comparison. The tops of the threads and the nonthreaded regions of all implants had very similar roughness parameters, independent of the geometry of the implant, which were also very similar to those of flat disks treated with the same process. In contrast, the flanks and valleys of the threads presented larger irregularities (Sa) with higher slopes (Sdq) and larger developed surface areas (Sdr) on all implants, particularly for implants with threads with smaller heights. The flanks and valleys displayed stronger textures (Str), particularly on the implants with threads with larger internal angles. Parameters associated with the height of the irregularities (Sa), the slope of the asperities (Sdq), the presence of a surface texture (Str), and the developed surface area of the irregularities (Sdr) were significantly affected by the macrogeometry of the implants. Flat disks subjected to the same surface treatment as dental implants reproduced only the surface topography of the flat regions of the implants.

  18. Effect of Heavy Smoking on Dental Implants Placed in Male Patients Posterior Mandibles: A Prospective Clinical Study.

    PubMed

    Sun, Cong; Zhao, Jinxiu; Jianghao, Chen; Hong, Tao

    2016-12-01

    The objective of this study was to evaluate the implant stability and peri-implant tissue response in heavy smokers receiving dental implants due to partially edentulous posterior mandibles. Forty-five ITI Straumann dental implants were placed into the partially edentulous posterior mandibles of 16 heavy smokers and 16 nonsmokers. One implant in each patient was evaluated for implant stability after surgery and before loading, and for the modified plaque index (mPLI), modified sulcus bleeding index (mSBI), probing depth (PD), and marginal bone loss (MBL) after loading. Meanwhile, the osteogenic capability of jaw marrow samples collected from patients was evaluated via an in vitro mineralization test. For both groups, the implant stability quotient (ISQ) initially decreased from the initial ISQ achieved immediately after surgery and then increased starting from 2 weeks postsurgery. However, at 3, 4, 6, and 8 weeks postsurgery, the ISQ differed significantly between nonsmokers and heavy smokers. All implants achieved osseointegration without complications at least by the end of the 12th week postsurgery. At 6 or 12 months postloading, the MBL and PD were significantly higher in heavy smokers than in nonsmokers, whereas the mSBI and mPLI did not differ significantly between the 2 groups. The 1-year cumulative success rate of implants was 100% for both groups. Within the limitations of the present clinical study (such as small sample size and short study duration), which applied the loading at 3 months postoperation, heavy smoking did not affect the cumulative survival rate of dental implants placed at the posterior mandible in male patients, but heavy smoking did negatively affect bone healing around dental implants by decreasing the healing speed. These results implied that it might be of importance to select the right time point to apply the implant loading for heavy smokers. In addition, heavy smoking promoted the loss of marginal bone and the further development of dental pockets. Further clinical studies with larger patient populations are warranted to confirm our findings over a longer study duration.

  19. Evaluation of a navigation system for dental implantation as a tool to train novice dental practitioners.

    PubMed

    Casap, Nardy; Nadel, Sahar; Tarazi, Eyal; Weiss, Ervin I

    2011-10-01

    This study evaluated the benefits of a virtual reality navigation system for teaching the surgical stage of dental implantation to final-year dental students. The study aimed to assess the students' performance in dental implantation assignments by comparing freehand protocols with virtual reality navigation. Forty final-year dentistry students without previous experience in dental implantation surgery were given an implantation assignment comprising 3 tasks. Marking, drilling, and widening of implant holes were executed by a freehand protocol on the 2 mandibular sides by 1 group and by virtual reality navigation on 1 side and contralaterally with the freehand protocol by the other group. Subjective and objective assessments of the students' performance were graded. Marking with the navigation system was more accurate than with the standard protocol. The 2 groups performed similarly in the 2-mm drilling on the 2 mandibular sides. Widening of the 2 mesial holes to 3 mm was significantly better with the second execution in the standard protocol group, but not in the navigation group. The navigation group's second-site freehand drilling of the molar was significantly worse than the first. The execution of all assignments was significantly faster in the freehand group than in the navigation group (60.75 vs 77.25 minutes, P = .02). Self-assessment only partly matched the objective measurements and was more realistic in the standard protocol group. Despite the improved performance with the navigation system, the added value of training in dental implantation surgery with virtual reality navigation was minimal. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Nano-crystalline diamond-coated titanium dental implants - a histomorphometric study in adult domestic pigs.

    PubMed

    Metzler, Philipp; von Wilmowsky, Cornelius; Stadlinger, Bernd; Zemann, Wolfgang; Schlegel, Karl Andreas; Rosiwal, Stephan; Rupprecht, Stephan

    2013-09-01

    Promising biomaterial characteristics of diamond-coatings in biomedicine have been described in the literature. However, there is a lack of knowledge about implant osseointegration of this surface modification compared to the currently used sandblasted acid-etched Ti-Al6-V4 implants. The aim of this study was to investigate the osseointegration of microwave plasma-chemical-vapour deposition (MWP-CVD) diamond-coated Ti-Al6-V4 dental implants after healing periods of 2 and 5 months. Twenty-four MWP-CVD diamond-coated and 24 un-coated dental titanium-alloy implants (Ankylos(®)) were placed in the frontal skull of eight adult domestic pigs. To evaluate the effects of the nano-structured surfaces on bone formation, a histomorphometric analysis was performed after 2 and 5 months of implant healing. Histomorphometry analysed the bone-to-implant contact (BIC). No significant difference in BIC for the diamond-coated implants in comparison to reference implants could be observed for both healing periods. Scanning electron microscopy revealed an adequate interface between the bone and the diamond surface. No delamination or particle-dissociation due to shearing forces could be detected. In this study, diamond-coated dental titanium-alloy implants and sandblasted acid-etched implants showed a comparable degree of osseointegration. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Thermodynamic effects of laser irradiation of implants placed in bone: an in vitro study.

    PubMed

    Leja, Chris; Geminiani, Alessandro; Caton, Jack; Romanos, Georgios E

    2013-11-01

    Lasers have been proposed for various applications involving dental implants, including uncovering implants and treating peri-implantitis. However, the effect of laser irradiation on the implant surface temperature is only partially known. The aim of this pilot study was to determine the effect of irradiation with diode, carbon dioxide, and Er:YAG lasers on the surface temperature of dental implants placed in bone, in vitro. For this study, one dental implant was placed in a bovine rib. A trephine bur was used to create a circumferential defect to simulate peri-implantitis, and thermocouples were placed at the coronal and apical aspect of the implant. The implant was irradiated for 60 s using four different lasers independently and change in temperature as well as time to reach a 10 °C increase in temperature were recorded. There was wide variability in results among the lasers and settings. Time for a 10 °C increase ranged from 0.9 to over 60 s for the coronal thermocouple and from 18 to over 60 s for the apical thermocouple. Maximum temperature ranged from 5.9 to 70.9 °C coronally and from 1.4 to 23.4 °C apically. During laser irradiation of dental implants, a surface temperature increase beyond the "critical threshold" of 10 °C can be reached after only 18 s.

  2. Patient satisfaction and aesthetic outcome of implant-supported single-tooth replacements performed by dental students: a retrospective evaluation 8 to 12 years after treatment.

    PubMed

    Bonde, Mikael Juul; Stokholm, Rie; Schou, Soren; Isidor, Flemming

    2013-01-01

    To assess patient satisfaction and aesthetic treatment outcome of implant-supported singletooth replacements performed by dental students as part of their undergraduate curriculum 8 to 12 years after treatment. A total of 51 patients were consecutively treated by dental students with 55 implant-supported single-tooth replacements within the incisor, canine and premolar regions. The surgical and prosthetic treatment was performed by the dental students under the supervision of dentists and oral and maxillofacial surgeons, all with specific knowledge about oral implantology. The outcome measures were patient subjective evaluation of peri-implant soft tissues, implant crown, implant function and total implant treatment using a Visual Analogue Scale (VAS). The professional evaluation included the peri-implant soft tissues, implant crown and total implant treatment (combined scores, PES/WES) using the Pink Esthetic Score (PES) and the White Esthetic Score (WES), as well as the level of incisor edge/occlusal surface in relation to neighbouring teeth. A total of 42 patients with 46 implants were available for evaluation 8 to 12 years after treatment. The patients were in general satisfied with the treatment outcome and few patients had low VAS scores. Most implants were characterised by single scores of 1 or 2 resulting in a mean PES score of 8.3 (maximum 14), a mean WES score of 6.3 (maximum 10) and a mean PES/WES score of 14.6 (maximum 24). However, 33% of the implants were characterised by recession (>1 mm) of the facial soft-tissue margin. Correlation analyses involving the subjective parameters indicated that the evaluation of the total implant treatment was mainly influenced by the appearance of the implant crown and to a lesser extent by the peri-implant mucosa. There were no significant correlations between the subjective and professional evaluation. Both the subjective and professional evaluation revealed implants in infraposition. This was registered in 7% and 17% of the implants, respectively. The patient satisfaction and aesthetic outcome 8 to 12 years after treatment with implant-supported single-tooth replacements performed by dental students as part of their clinical undergraduate dental curriculum were characterised by high patient satisfaction and an acceptable aesthetic treatment outcome. Therefore, it seems acceptable to include implant therapy of straightforward cases in the clinical undergraduate curriculum, provided there is substantial supervision by trained clinicians. The study was partially supported by Nobel Biocare, Denmark. There was no conflict of interest.

  3. Zirconia Dental Implants: Investigation of Clinical Parameters, Patient Satisfaction, and Microbial Contamination.

    PubMed

    Holländer, Jens; Lorenz, Jonas; Stübinger, Stefan; Hölscher, Werner; Heidemann, Detlef; Ghanaati, Shahram; Sader, Robert

    2016-01-01

    In recent years, dental implants made from zirconia have been further developed and are considered a reliable treatment method for replacing missing teeth. The aim of this study was to analyze dental implants made from zirconia regarding their clinical performance compared with natural teeth (control). One hundred six zirconia implants in 38 adults were analyzed in a clinical study after 1 year of loading. The plaque index (PI), bleeding on probing (BOP), probing pocket depth (PPD), probing attachment level (PAL), and creeping or recession (CR/REC) of the gingiva were detected and compared with natural control teeth (CT). Furthermore, the papilla index (PAP), Periotest values (PTV), microbial colonization of the implant/dental sulcus fluid, and patient satisfaction were assessed. The survival rate was 100%. No statistical significance was observed between implants and teeth regarding BOP, PPD, and PAL. A statistical significance was detected regarding PI and CR/REC with significantly less plaque accumulation and recession in the study group. Mean PAP was 1.76 ± 0.55, whereas the mean PTV was -1.31 ± 2.24 (range from -5 to +6). A non-statistically significant higher colonization of periodontitis/peri-implantitis bacteria was observed in the implant group. The questionnaire showed that the majority of the patients were satisfied with the overall treatment. One-piece zirconia dental implants exhibited similar clinical results (BOP, PPD, and PAL) compared with natural teeth in regard to adhesion of plaque (PI) and creeping attachment (CR/REC); zirconia implants performed even better. The favorable results for PAL and CR/REC reflect the comparable low affinity of zirconia for plaque adhesion. Patient satisfaction indicated a high level of acceptance for zirconia implants. However, a long-term follow-up is needed to support these findings.

  4. Impact of heavy smoking on the clinical, microbiological and immunological parameters of patients with dental implants: a prospective cross-sectional study.

    PubMed

    Ata-Ali, Javier; Flichy-Fernández, Antonio Juan; Alegre-Domingo, Teresa; Ata-Ali, Fadi; Peñarrocha-Diago, Miguel

    2016-11-01

    The aim of the present study was to investigate how heavy smoking influences the clinical, microbiological, and host-response characteristics in peri-implant sulcus fluid of patients with healthy dental implants. A total of 29 individuals with 74 dental implants were included in the present study; 20 implants were in heavy smokers and 54 were in non-smokers. The modified gingival index, modified plaque index, and probing pocket depth were evaluated. Periodontopathogenic bacteria Tannerella forsythia, Treponema denticola, and Porphyromonas gingivalis were evaluated, together with the total bacterial load. Peri-implant sulcus fluid samples were analyzed for the quantification of interleukin-8, interleukin-1β, interleukin-6, interleukin-10, and tumor necrosis factor-α. No significant differences in the clinical parameters evaluated were found between the groups, although smokers had poorer peri-implant parameters. Among the smokers, subgingival microbiota was composed of a greater number of periodontal pathogens; these differences were not statistically significant. Smokers showed a greater expression of interleukin-1β, interleukin-6, interleukin-10, and tumor necrosis factor-α, but interleukin-8 was slightly higher among non-smokers, but not significantly. Although smokers presented deeper probing depths, bleeding on probing, and peri-implant microbiota composed of a greater number of periodontal pathogens than in non-smoking patients, these data did not show significant differences. In the present study, and in relation to the samples analyzed, smoking alone did not influence the immunological and microbiological parameters in dental implants with healthy peri-implant tissues. Further studies with larger samples are required to better evaluate the influence of smoking on dental implants. © 2015 Wiley Publishing Asia Pty Ltd.

  5. Comparative bone tissue integration of nanostructured and microroughened dental implants.

    PubMed

    Salou, Laëtitia; Hoornaert, Alain; Stanovici, Julien; Briand, Sylvain; Louarn, Guy; Layrolle, Pierre

    2015-01-01

    The aim was to compare osteointegration of nanostructured implants to a microsurface widely used for titanium dental implants. Commercial titanium dental implants with smooth or microroughened surfaces were nanostructured. Implants were inserted into the femoral condyles of rabbits. After 2 and 4 weeks, histomorphometry calculation was performed. Nanotubes measuring 60 nm in diameter were observed on both S-NANO (roughness: 0.05 μm) and R-NANO (roughness: 0.40 μm) surfaces. The MICRO surface exhibited typical random cavities (roughness: 2.09 μm). At 4 weeks, bone-to-implant contact values were significantly higher for the R-NANO than for the MICRO surface while no differences were observed at 2 weeks. Overall, this study shows that the nanostructured surfaces improved osteointegration similar or higher than the MICRO.

  6. B-Cure Laser Dental Pro technology for prevention and treatment of peri-implant mucositis

    NASA Astrophysics Data System (ADS)

    Gileva, O. S.; Libik, T. V.; Chuprakov, M. A.; Yakov, A. Y.; Mirsaeva, F. Z.

    2017-09-01

    Oral mucositis (OM) is the severe inflammation, lesioning and ulceration of the epithelia, accompanied by bleeding and intensive pain. OM is a common complication of dental implantation. Low-level laser therapy (LLLT) has been found to enhance the repair and healing of epithelia. The aim of this study was to evaluate the effectiveness of preventive and treatment use of LLLT (B-Cure Laser Dental Pro technology in original author's techniques) in the patients who have undergone dental implantation. Simple blind randomized prospective one-center comparative placebo-controlled clinical trial is carried out on the group of 30 partially edentulous patients. It is proved that the use of LLLT before and after installation of dental implants provides: 1) reliable reduction (by 3.5 times) of the frequency of implication and intensity of pain in the first days after operation; 2) reduction (by 3.3-3.7 times) of frequency, duration and intensity of local edematous and inflammatory processes in peri-implant zone and facial soft tissue edema; 3) effective prophylaxis of postoperative sensory, paresthesia and neurologic disturbances in maxillofacial area.

  7. Magnetic Resonance Imaging Distortion and Targeting Errors from Strong Rare Earth Metal Magnetic Dental Implant Requiring Revision.

    PubMed

    Seong-Cheol, Park; Chong Sik, Lee; Seok Min, Kim; Eu Jene, Choi; Do Hee, Lee; Jung Kyo, Lee

    2016-12-22

    Recently, the use of magnetic dental implants has been re-popularized with the introduction of strong rare earth metal, for example, neodymium, magnets. Unrecognized magnetic dental implants can cause critical magnetic resonance image distortions. We report a case involving surgical failure caused by a magnetic dental implant. A 62-year-old man underwent deep brain stimulation for medically insufficiently controlled Parkinson's disease. Stereotactic magnetic resonance imaging performed for the first deep brain stimulation showed that the overdenture was removed. However, a dental implant remained and contained a neodymium magnet, which was unrecognized at the time of imaging; the magnet caused localized non-linear distortions that were the largest around the dental magnets. In the magnetic field, the subthalamic area was distorted by a 4.6 mm right shift and counter clockwise rotation. However, distortions were visually subtle in the operation field and small for distant stereotactic markers, with approximately 1-2 mm distortions. The surgeon considered the distortion to be normal asymmetry or variation. Stereotactic marker distortion was calculated to be in the acceptable range in the surgical planning software. Targeting errors, approximately 5 mm on the right side and 2 mm on the left side, occurred postoperatively. Both leads were revised after the removal of dental magnets. Dental magnets may cause surgical failures and should be checked and removed before stereotactic surgery. Our findings should be considered when reviewing surgical precautions and making distortion-detection algorithm improvements.

  8. Clinical evaluation of immediate loading of electroeroded screw-retained titanium fixed prostheses supported by tilted implant: a multicenter retrospective study.

    PubMed

    Acocella, Alessandro; Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Billi, Mauro; Acocella, Gabriele; Giannini, Domenico; Sacco, Roberto

    2012-05-01

    Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long-term data available in the literature, when an electroeroded definitive cast-titanium fixed prosthesis is used for this treatment protocol. The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast-titanium screw-retained fixed prosthesis. Forty-five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin-titanium screw-retained prosthesis fabricated by electroerosion. Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%. Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw-retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results. © 2011 Wiley Periodicals, Inc.

  9. Impact of the Static and Radiofrequency Magnetic Fields Produced by a 7T MR Imager on Metallic Dental Materials.

    PubMed

    Oriso, Kenta; Kobayashi, Takuya; Sasaki, Makoto; Uwano, Ikuko; Kihara, Hidemichi; Kondo, Hisatomo

    2016-01-01

    We examined safety issues related to the presence of various metallic dental materials in magnetic resonance (MR) imaging at 7 tesla. A 7T MR imaging scanner was used to examine 18 kinds of materials, including 8 metals used in dental restorations, 6 osseointegrated dental implants, 2 abutments for dental implants, and 2 magnetic attachment keepers. We assessed translational attraction forces between the static magnetic field and materials via deflection angles read on a tailor-made instrument and compared with those at 3T. Heating effects from radiofrequency during image acquisitions using 6 different sequences were examined by measuring associated temperature changes in agarose-gel phantoms with a fiber-optic thermometer. Deflection angles of the metallic dental materials were significantly larger at 7T than 3T. Among full metal crowns (FMCs), deflection angles were 18.0° for cobalt-chromium (Co-Cr) alloys, 13.5° for nickel-chromium (Ni-Cr) alloys, and 0° for other materials. Deflection angles of the dental implants and abutments were minimal, ranging from 5.0 to 6.5°, whereas the magnetic attachment keepers were strongly attracted to the field, having deflection angles of 90° or more. Increases in temperature of the FMCs were significant but less than 1°C in every sequence. The dental implant of 50-mm length showed significant but mild temperature increases (up to 1.5°C) when compared with other dental implants and abutments, particularly on sequences with high specific absorption rate values. Although most metallic dental materials showed no apparent translational attraction or heating at 7T, substantial attraction forces on the magnetic attachment keepers suggested potential risks to patients and research participants undergoing MR imaging examinations.

  10. Dental Implant Patients and Their Satisfaction with Treatment.

    ERIC Educational Resources Information Center

    Tawares, Mary; And Others

    1990-01-01

    The study developed a profile of dental implant patients from 38 private practices to document characteristics of endosseous implant recipients of the past 10 years. Data were then analyzed using multivariate techniques to examine the relationship between these characteristics and patient-reported outcomes. Patients tended to have high incomes and…

  11. Lasers in dental implantology.

    PubMed

    Martin, Emile

    2004-10-01

    The parallels in the expansion of implant dentistry and laser dentistry in clinical practice are apparent. As advocates for laser dentistry continue to seek new ways to use the technology and as more practitioners become involved in implant dentistry, it is logical to see the concurrent use of both technologies in clinical practice. This article provides data that clearly support the value of dental lasers in the practice of implant dentistry. The challenge for the practitioner is the same as for any other area of dentistry: knowing when, where, and what armamentarium to use in any given situation. Not all dental laser wavelengths are necessarily useful in every dental implant situation. After clinicians know the characteristics of the wavelengths available to them, the application of the technology to the specific situation certainly is warranted.

  12. A Retrospective Analysis of Dental Implants Replacing Failed Implants in Grafted Maxillary Sinus: A Case Series.

    PubMed

    Manor, Yifat; Chaushu, Gavriel; Lorean, Adi; Mijiritzky, Eithan

    2015-01-01

    To evaluate the survival rate of dental implants replacing failed implants in grafted maxillary sinuses using the lateral approach vs nongrafted posterior maxillae. A retrospective analysis was conducted to study the survival of secondary dental implants inserted in the posterior maxilla in previously failed implant sites between the years 2000 and 2010. The study group consisted of patients who had also undergone maxillary sinus augmentation, and the control group consisted of patients in whom implants in the posterior maxilla had failed. Clinical and demographic data were analyzed using a structured form. Seventy-five patients with a total of 75 replaced implants were included in the study. The study group comprised 40 patients and the control group, 35 patients. None of the replaced implants in the study group failed, resulting in an overall survival of 100%; three replaced implants in the control group failed (92% survival). The main reason for the primary implant removal was lack of osseointegration (35 [87.5%] of 40 study group implants and 23 [65.7%] of 35 control group implants [P = .027]). The difference between the groups with regard to the timing of primary implant failure was statistically significant. The study group had more early failures of the primary implant than did the control group (77% vs 62%; P = .038). Dental implants replaced in the posterior maxilla had a high survival rate. A higher rate of survival was found in augmented maxillary sinus sites. Within the limits of the present study, it can be concluded that previous implant failures in the grafted maxillary sinus should not discourage practitioners from a second attempt.

  13. Irradiated patients and survival rate of dental implants: A systematic review and meta-analysis.

    PubMed

    Smith Nobrega, Adhara; Santiago, Joel Ferreira; de Faria Almeida, Daniel Augusto; Dos Santos, Daniela Micheline; Pellizzer, Eduardo Piza; Goiato, Marcelo Coelho

    2016-12-01

    Radiotherapy has been considered a contraindication for rehabilitation with dental implants because it can change the survival rate of implants. Nevertheless, the installation of implants in irradiated patients has been used with varying success. The purpose of this systematic review was to compare the success rate of implants placed in irradiated human bone tissue with that of implants placed in nonirradiated areas. Searches were performed in the EMBASE, Cochrane, and PubMed/Medline databases up to December 2013 to identify clinical trials addressing the subject. This systematic review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The relative risks of implant failure and survival curves were calculated considering a confidence interval of 95%. Heterogeneity was analyzed by using a funnel chart. A total of 40 studies involving 2220 participants and 9231 dental implants were selected. The survival curve of the studies indicated a survival rate of 84.3% for implants installed in irradiated bone tissue. The meta-analysis indicated statistically significant differences (P<.001) between item success rates of implants placed in irradiated areas and those of implants placed in nonirradiated areas. Dental implants installed in the irradiated area of an oral cavity have a high survival rate, but strict monitoring is needed to prevent complications, thereby reducing possible failures. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Low-level laser therapy with 940 nm diode laser on stability of dental implants: a randomized controlled clinical trial.

    PubMed

    Torkzaban, Parviz; Kasraei, Shahin; Torabi, Sara; Farhadian, Maryam

    2018-02-01

    Low-level laser therapy (LLLT) is a non-invasive modality to promote osteoblastic activity and tissue healing. The aim of this study was to evaluate the efficacy of LLLT for improvement of dental implant stability. This randomized controlled clinical trial was performed on 80 dental implants placed in 19 patients. Implants were randomly divided into two groups (n = 40). Seven sessions of LLLT (940 nm diode laser) were scheduled for the test group implants during 2 weeks. Laser was irradiated to the buccal and palatal sides. The same procedure was performed for the control group implants with laser hand piece in "off" mode. Implant stability was measured by Osstell Mentor device in implant stability quotient (ISQ) value immediately after surgery and 10 days and 3, 6, and 12 weeks later. Repeated measures ANOVA was used to compare the mean ISQ values (implant stability) in the test and control groups. Statistical test revealed no significant difference in the mean values of implant stability between the test and control groups over time (P = 0.557). Although the mean values of implant stability changed significantly in both groups over time (P < 0.05). Although the trend of reduction in stability was slower in the laser group in the first weeks and increased from the 6th to 12th week, LLLT had no significant effect on dental implant stability.

  15. Assessing perceptions of oral health related quality of life in dental implant patients. Experience of a tertiary care center in India.

    PubMed

    Paul S, Arun; Simon S, Sibu; Kumar, Saurabh; Chacko, Rabin K

    2018-01-01

    Patients perception of treatment outcomes are invaluable assessment tools and are effective indicators for future prognosis. Various tools of measurement have been used to assess the same. The oral health impact profile questionnaire (OHIP 14) has been effectively used to evaluate the oral health-related quality of life (OHRQoL) with regards to individual perceptions. This study was conducted to assess OHRQoL in patients who have had dental implants to replace missing teeth in the Department of Dental Surgery, Unit 1, Christian Medical College and Hospital, Vellore, TN, India by using the OHIP 14 questionnaire. A total of 107 patients who had treatment with dental implants were sent a modified form of the OHIP 14 questionnaire. An attempt was made to draw an inference by correlating scores of the OHIP 14 with data pertaining to key independent variables. Gamma regression was applied to the results as the outcome score distribution was skewed. All statistical analyses were performed using SPSS Version 21.0. The mean score for the OHIP 14 was 16.82 with the highest score of 30 for a total score of 70. OHIP 14 scores were higher in patients with implant-supported fixed dental prosthesis as compared to patients with single implant supported crowns (P = 0.0069). Patients with no complaints scored 9% lesser than those who reported complaints (P = 0.0438). Assessing quality of life with regards to specific treatment interventions may help to draw critical inferences that determine overall success. Results from the study enabled us to delineate and appreciate the success imparted by esthetics and function from the general well being imparted by treatment with dental implants. Social media could be used to positively improve responses in questionnaire based studies. Future studies using implant specific OHRQoL questionnaire may help to elicit unbiased patient perception in dental implant patients.

  16. Prostaglandin E2 Receptor Expression by Osteoblasts is Modulated by Implant Surface Roughness and Prostaglandin E2

    DTIC Science & Technology

    2006-05-01

    al. 1996; Trancik et al. 1989). Thus, it is of vital importance to the field of dental implantology to investigate how prostaglandins mediate their...of Texas Graduate School of Biomedical Sciences at San Antonio Supervising Professor: David D. Dean, Ph.D. While the predictability of dental implants...control media lacking PGE2. Cells were incubated for an additional 3, 6, or 120 hrs to simulate the early response after dental implant placement, after

  17. Dental implants placement in paranoid squizofrenic patient with obsessive-compulsive disorder: A case report

    PubMed Central

    Castellanos-Cosano, Lizett; Corcuera-Flores, José-Ramón; Mesa-Cabrera, María; Cabrera-Domínguez, José; Torres-Lagares, Daniel; Machuca-Portillo, Guillermo

    2017-01-01

    Background Paranoid schizophrenia is a mental illness that involves no observable anatomical alteration. Main characteristic affects the personality of the individual, as well as areas of his own psychology. Case Report A 33-year-old man with paranoid schizophrenia and obsessive-compulsive disorder in treatment with Haloperidol, Oxcarbazepine, Olanzapine and Seroquel is presented. Dental exploration showed widespread decay mostly cervical with numerous root fragments, agenesis of lateral incisors, impacted wisdom teeth, missing teeth and malocclusion. Treatment plan included restoration of teeth decay, extractions of root fragments and implant-supported prostheses in bilateral upper lateral incisors for aesthetics reason. A previous consultation with a psychiatric specialist was performed and no contraindication were observed. A preliminary radiological examination was performed previous dental treatment and implant placement. Due to patient refusal to replace dental abscenses with implants, inform consent was signed up from his parents. After local anesthesia, first implant was placed at upper right lateral positions (Straumann Bone Level Ø 3.3 mm, length 10 mm). Two weeks later a second implant was placed at upper left lateral position (Straumann Bone Level Ø 3.3 mm, length 12 mm). The patient showed no postoperative complications. After implant placement, the patient attended scheduled review appointments. The prosthesis was placed after a 3-month period of osseointegration. Conclusions Implant placement can be considered a suitable option for people with mental disorders. A previous consultation with psychiatric specialists for conducting a good patient management is necessaire. Key words:Paranoid schizophrenia, obsessive-compulsive disorder, dental implants. PMID:29302292

  18. Bruxism and dental implant failures: a multilevel mixed effects parametric survival analysis approach.

    PubMed

    Chrcanovic, B R; Kisch, J; Albrektsson, T; Wennerberg, A

    2016-11-01

    Recent studies have suggested that the insertion of dental implants in patients being diagnosed with bruxism negatively affected the implant failure rates. The aim of the present study was to investigate the association between the bruxism and the risk of dental implant failure. This retrospective study is based on 2670 patients who received 10 096 implants at one specialist clinic. Implant- and patient-related data were collected. Descriptive statistics were used to describe the patients and implants. Multilevel mixed effects parametric survival analysis was used to test the association between bruxism and risk of implant failure adjusting for several potential confounders. Criteria from a recent international consensus (Lobbezoo et al., J Oral Rehabil, 40, 2013, 2) and from the International Classification of Sleep Disorders (International classification of sleep disorders, revised: diagnostic and coding manual, American Academy of Sleep Medicine, Chicago, 2014) were used to define and diagnose the condition. The number of implants with information available for all variables totalled 3549, placed in 994 patients, with 179 implants reported as failures. The implant failure rates were 13·0% (24/185) for bruxers and 4·6% (155/3364) for non-bruxers (P < 0·001). The statistical model showed that bruxism was a statistically significantly risk factor to implant failure (HR 3·396; 95% CI 1·314, 8·777; P = 0·012), as well as implant length, implant diameter, implant surface, bone quantity D in relation to quantity A, bone quality 4 in relation to quality 1 (Lekholm and Zarb classification), smoking and the intake of proton pump inhibitors. It is suggested that the bruxism may be associated with an increased risk of dental implant failure. © 2016 John Wiley & Sons Ltd.

  19. Relationship between sponsorship and failure rate of dental implants: a systematic approach.

    PubMed

    Popelut, Antoine; Valet, Fabien; Fromentin, Olivier; Thomas, Aurélie; Bouchard, Philippe

    2010-04-21

    The number of dental implant treatments increases annually. Dental implants are manufactured by competing companies. Systematic reviews and meta-analysis have shown a clear association between pharmaceutical industry funding of clinical trials and pro-industry results. So far, the impact of industry sponsorship on the outcomes and conclusions of dental implant clinical trials has never been explored. The aim of the present study was to examine financial sponsorship of dental implant trials, and to evaluate whether research funding sources may affect the annual failure rate. A systematic approach was used to identify systematic reviews published between January 1993 and December 2008 that specifically deal with the length of survival of dental implants. Primary articles were extracted from these reviews. The failure rate of the dental implants included in the trials was calculated. Data on publication year, Impact Factor, prosthetic design, periodontal status reporting, number of dental implants included in the trials, methodological quality of the studies, presence of a statistical advisor, and financial sponsorship were extracted by two independent reviewers (kappa = 0.90; CI(95%) [0.77-1.00]). Univariate quasi-Poisson regression models and multivariate analysis were used to identify variables that were significantly associated with failure rates. Five systematic reviews were identified from which 41 analyzable trials were extracted. The mean annual failure rate estimate was 1.09%.(CI(95%) [0.84-1.42]). The funding source was not reported in 63% of the trials (26/41). Sixty-six percent of the trials were considered as having a risk of bias (27/41). Given study age, both industry associated (OR = 0.21; CI(95%) [0.12-0.38]) and unknown funding source trials (OR = 0.33; (CI(95%) [0.21-0.51]) had a lower annual failure rates compared with non-industry associated trials. A conflict of interest statement was disclosed in 2 trials. When controlling for other factors, the probability of annual failure for industry associated trials is significantly lower compared with non-industry associated trials. This bias may have significant implications on tooth extraction decision making, research on tooth preservation, and governmental health care policies.

  20. Effect of Induced Periimplantitis on Dental Implants With and Without Ultrathin Hydroxyapatite Coating.

    PubMed

    Madi, Marwa; Zakaria, Osama; Ichinose, Shizuko; Kasugai, Shohei

    2016-02-01

    The aim of this study was to compare the effect of ligature-induced periimplantitis on dental implants with and without hydroxyapatite (HA) coat. Thirty-two dental implants (3.3 mm wide, 13 mm long) with 4 surface treatments (8 implant/group) (M: machined, SA: sandblasted acid etched, S: sputter HA coat and P: plasma-sprayed HA coat) were inserted into canine mandibles. After 12 weeks, oral hygiene procedures were stopped and silk ligatures were placed around the implant abutments to allow plaque accumulation for the following 16 weeks. Implants with the surrounding tissues were retrieved and prepared for histological examination. Bone-to-implant contact (BIC) and implant surfaces were examined using scanning electron microscopy and energy dispersive x-ray spectroscopy. Histological observation revealed marginal bone loss and large inflammatory cell infiltrates in the periimplant soft tissue. Sputter HA implants showed the largest BIC (98.1%) and machined implant showed the smallest values (70.4%). After 28 weeks, thin sputter HA coat was almost completely dissolved, whereas plasma-sprayed HA coat showed complete thickness preservation. Thin sputter HA-coated implants showed more bone implant contact and less marginal bone loss than thick HA-coated implants under periimplantitis condition.

  1. Surface Damage on Dental Implants with Release of Loose Particles after Insertion into Bone.

    PubMed

    Senna, Plinio; Antoninha Del Bel Cury, Altair; Kates, Stephen; Meirelles, Luiz

    2015-08-01

    Modern dental implants present surface features of distinct dimensions that can be damaged during the insertion procedure into bone. The aims of this study were (1) to quantify by means of roughness parameters the surface damage caused by the insertion procedure of dental implants and (2) to investigate the presence of loose particles at the interface. Three groups of dental implants representing different surface topographies were inserted in fresh cow rib bone blocks. The surface roughness was characterized by interferometry on the same area before and after the insertion. Scanning electron microscopy (SEM)-back-scattered electron detector (BSD) analysis was used to identify loose particles at the interface. The amplitude and hybrid roughness parameters of all three groups were lower after insertion. The surface presenting predominance of peaks (Ssk [skewness] > 0) associated to higher structures (height parameters) presented higher damage associated to more pronounced reduction of material volume. SEM-BSD images revealed loose titanium and aluminum particles at the interface mainly at the crestal cortical bone level. Shearing forces during the insertion procedure alters the surface of dental implants. Loose metal particles can be generated at bone-implant interface especially around surfaces composed mainly by peaks and with increased height parameters. © 2013 Wiley Periodicals, Inc.

  2. Surface Damage on Dental Implants with Release of Loose Particles after Insertion into Bone

    PubMed Central

    Senna, Plinio; Del Bel Cury, Altair Antoninha; Kates, Stephen; Meirelles, Luiz

    2015-01-01

    Background Modern dental implants present surface features of distinct dimensions that can be damaged during the insertion procedure into bone. Purpose The aims of this study were (1) to quantify by means of roughness parameters the surface damage caused by the insertion procedure of dental implants and (2) to investigate the presence of loose particles at the interface. Materials and Methods Three groups of dental implants representing different surface topographies were inserted in fresh cow rib bone blocks. The surface roughness was characterized by interferometry on the same area before and after the insertion. SEM-BSD analysis was used to identify loose particles at the interface. Results The amplitude and hybrid roughness parameters of all three groups were lower after insertion. The surface presenting predominance of peaks (Ssk>0) associated to higher structures (height parameters) presented higher damage associated to more pronounced reduction of material volume. SEM-BSD images revealed loose titanium and aluminum particles at the interface mainly at the crestal cortical bone level. Conclusions Shearing forces during the insertion procedure alters the surface of dental implants. Loose metal particles can be generated at bone-implant interface especially around surfaces composed mainly by peaks and with increased height parameters. PMID:24283455

  3. Surface Modifications and Their Effects on Titanium Dental Implants

    PubMed Central

    Jemat, A.; Ghazali, M. J.; Razali, M.; Otsuka, Y.

    2015-01-01

    This review covers several basic methodologies of surface treatment and their effects on titanium (Ti) implants. The importance of each treatment and its effects will be discussed in detail in order to compare their effectiveness in promoting osseointegration. Published literature for the last 18 years was selected with the use of keywords like titanium dental implant, surface roughness, coating, and osseointegration. Significant surface roughness played an important role in providing effective surface for bone implant contact, cell proliferation, and removal torque, despite having good mechanical properties. Overall, published studies indicated that an acid etched surface-modified and a coating application on commercial pure titanium implant was most preferable in producing the good surface roughness. Thus, a combination of a good surface roughness and mechanical properties of titanium could lead to successful dental implants. PMID:26436097

  4. Transition from a fixed implant dental prosthesis to an implant overdenture in an edentulous patient: a clinical report.

    PubMed

    Ali, Bolouri; Bhavani, Venkatachalam

    2014-09-01

    The lack of planning before implant placement and restoration in edentulous patients can lead to a number of problems. Prosthodontists are often faced with the challenge of re-treating patients who have only recently been treated. Although many reports discuss retreatment by fabricating all new prosthetic components, few discuss salvaging parts of the patient's existing prosthesis. This report details the treatment of an edentulous patient who presented with an implant-retained fixed dental prosthesis in the maxillary arch and no opposing prosthesis. The transition from an implant-retained fixed dental prosthesis to a removable implant- and tissue-supported overdenture that uses the patient's existing computer-aided design/computer-aided manufacturing milled titanium substructure is described. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. Angulated Implants for Fabrication of Implant Supported Fixed Partial Denture in the Maxilla

    PubMed Central

    Egbert, Nicholas; Ahuja, Swati; Selecman, Audrey; Wicks, Russell

    2017-01-01

    Until recently, angled abutments have been the only solution to correcting the trajectory of the emergence profile of labially inclined implants in the maxilla. However, the clinical implications of angled abutments reveal several shortcomings. Newly designed angulated implants with a 12-degree restorative platform angulation are an alternative to angled abutments. The purpose of this article was to report a case utilizing new angulated implants (Co-axis, Keystone dental, Burlington, MA, USA) in the premaxilla thereby facilitating fabrication of a multi-unit implant retained fixed dental prosthesis. PMID:29201975

  6. Evaluation of Stress Distribution of Mini Dental Implant-Supported Overdentures in Complete Cleft Palate Models: A Three-Dimensional Finite Element Analysis Study.

    PubMed

    Soğancı, Gökçe; Yazıcıoğlu, Hüseyin

    2016-01-01

    Mini dental implants could be an alternative treatment method for prosthetic treatment of edentulous cleft palate. The aim of this study was to analyze stress distribution around the cortical bone and different plans using a varied number of mini dental implants in edentulous unilateral complete cleft palates. Three edentulous maxillary models were modified to create unilateral complete cleft palates. Mini dental implants (2.4 × 15 mm) were located as two mini implants at the premolar region, four mini implants at the premolar and molar region, and six mini implants at the first premolar, second premolar, and first molar regions in the models, respectively. Mucosa, o-ring/ball attachments, and overdentures were simulated. Vertical and horizontal loads of 100 N were applied on both the right and left molar teeth of the overdenture for each model. Maximum and minimum principal stress values and the distribution at cortical bone around the implants and cleft palates were evaluated by finite element analysis. Stress values under vertical loads were lower than values under horizontal loadings for all models. Stress values were found to be lower in the first model than in the second and third models. The highest stress values were found around implants in the second model. The unilateral feature of a complete cleft pattern affected the stress distribution. Stresses occured mostly around implants when the overdenture was supported by six implants; however, the stress distribution around implants was low with two implants because of tissue support.

  7. Nanotechnology Approaches for Better Dental Implants

    PubMed Central

    Tomsia, Antoni P.; Launey, Maximilien E.; Lee, Janice S.; Mankani, Mahesh H.; Wegst, Ulrike G.K.; Saiz, Eduardo

    2011-01-01

    The combined requirements imposed by the enormous scale and overall complexity of designing new implants or complete organ regeneration are well beyond the reach of present technology in many dimensions, including nanoscale, as we do not yet have the basic knowledge required to achieve these goals. The need for a synthetic implant to address multiple physical and biological factors imposes tremendous constraints on the choice of suitable materials. There is a strong belief that nanoscale materials will produce a new generation of implant materials with high efficiency, low cost, and high volume. The nanoscale in materials processing is truly a new frontier. Metallic dental implants have been successfully used for decades but they have serious shortcomings related to their osseointegration and the fact that their mechanical properties do not match those of bone. This paper reviews recent advances in the fabrication of novel coatings and nanopatterning of dental implants. It also provides a general summary of the state of the art in dental implant science and describes possible advantages of nanotechnology for further improvements. The ultimate goal is to produce materials and therapies that will bring state-of-the-art technology to the bedside and improve quality of life and current standards of care. PMID:21464998

  8. The effect of cigarette smoking and native bone height on dental implants placed immediately in sinuses grafted by hydraulic condensation.

    PubMed

    Lin, Thomas H S; Chen, Leon; Cha, Jennifer; Jeffcoat, Marjorie; Kao, Daniel W K; Nevins, Myron; Fiorellini, Joseph P

    2012-06-01

    The purpose of this study was to determine the effect of cigarette smoking and residual native bone height on the survival of dental implants placed immediately in grafted sinuses. In this retrospective study, 334 subject records were screened, and 75 subjects (155 implants) were included. Data collection based on treatment notes and radiographs included age, sex, smoking status, sinus floor bone height, dental implant information, and implant survival. The survival rates of implants for nonsmokers and smokers at stage-two surgery were 93% and 84%, respectively. After 12 months of functional loading, the survival rates of implants for nonsmokers and smokers were 87% (81 of 93) and 79% (49 of 62), respectively (P < .000). Analysis revealed that the effect of smoking on implant survival is significant when the preoperative bone height is less than 4 mm, with an 82.4% implant survival rate in nonsmokers compared to 60% in smokers (P < .05). Smoking should be considered as a high risk factor when implants are placed immediately in grafted sinuses, particularly in areas of limited bone height.

  9. Predoctoral dental implant education at Creighton University School of Dentistry.

    PubMed

    Parrish, Lawrence; Hunter, Richard; Kimmes, Nici; Wilcox, Charles; Nunn, Martha; Miyamoto, Takanari

    2013-05-01

    The purpose of this report is to describe the dental implant education that predoctoral students receive and to characterize the patient population receiving implants at Creighton University School of Dentistry (CDS). CDS has no postdoctoral residency programs. Therefore, clinical management of diagnosis, treatment planning, surgical aspects, restoration, complications, and maintenance of dental implants requires significant involvement by predoctoral dental students. CDS implant education involves radiology diagnostic assets of the General Dentistry Department (including the use of Cone Beam Computed Tomography), as well as faculty and equipment from the Departments of Oral and Maxillofacial Surgery, Periodontics, and Prosthodontics, with a majority of students satisfied with their didactic preparation for their clinical experiences. Focusing on a three-year window from August 2007 to August 2010 and using electronic health records, this study found that a total of 242 implants were placed, out of which six failed within one year of placement and had to be removed. The average age of the population of 153 patients was found to be 53.3 years, with a range of eighteen to eighty-nine. Treatment outcomes compared very favorably with those published in the literature.

  10. Reactive oral lesions associated with dental implants. A systematic review.

    PubMed

    Atarbashi-Moghadam, Fazele; Atarbashi-Moghadam, Saede; Namdari, Mahshid; Shahrabi-Farahani, Shokoufeh

    2018-05-11

    Reactive lesion formation around dental implants a complication that has been given much consideration. These lesions can lead to marginal bone loss, and consequently, implant failure. In the present systematic review, all reported reactive lesions associated with dental implants in the literature were assessed. An electronic search was performed using PubMed Central, Scopus, Google Scholar, and Science Direct. The search strategy was limited to human studies (case reports and case series), full-text English language articles, published until May 2017. A total of 19 articles reporting 27 lesions in 25 cases were included. Peripheral giant cell granuloma and pyogenic granuloma were the most reactive lesions found around dental implants. The mean age of the patients was 51.28 ± 14.48 years, with a slight female predilection. Posterior mandibular gingiva was the most common location for these lesions. The recurrence rate of lesions was 33.33%, and the chance of implant removal was 29.62%. Due to the clinical significance of these lesions, early histopathologic examination is recommended to exclude the presence of such pathological lesions. © 2018 John Wiley & Sons Australia, Ltd.

  11. Assessment of Surface Area Characteristics of Dental Implants with Gradual Bioactive Surface Treatment

    NASA Astrophysics Data System (ADS)

    Czan, Andrej; Babík, Ondrej; Miklos, Matej; Záušková, Lucia; Mezencevová, Viktória

    2017-10-01

    Since most of the implant surface is in direct contact with bone tissue, shape and integrity of said surface has great influence on successful osseointegration. Among other characteristics that predetermine titanium of different grades of pureness as ideal biomaterial, titanium shows high mechanical strength making precise miniature machining increasingly difficult. Current titanium-based implants are often anodized due to colour coding. This anodized layer has important functional properties for right usage and also bio-compatibility of dental implants. Physical method of anodizing and usage of anodizing mediums has a significant influence on the surface quality and itself functionality. However, basic requirement of the dental implant with satisfactory properties is quality of machined surface before anodizing. Roughness, for example, is factor affecting of time length of anodizing operation and so whole productivity. The paper is focused on monitoring of surface and area characteristics, such as roughness or surface integrity after different cutting conditions of miniature machining of dental implants and their impact on suitability for creation of satisfactory anodized layer with the correct biocompatible functional properties.

  12. Quasi-static strength and fractography analysis of two dental implants manufactured by direct metal laser sintering.

    PubMed

    Gehrke, Sergio Alexandre; Pérez-Díaz, Leticia; Dedavid, Berenice Anina

    2018-06-01

    New manufacturing methods was developed to improve the tissues integration with the titanium alloy pieces. The present in vitro study was to assess the resistance and fracture mode after applied a quasi-static compressive force on the two dental implants manufactured by direct metal laser sintering. Twenty dental implants manufactured by direct metal laser sintering, using titanium alloy (Ti-6Al-4V) granules in two designs (n = 10 per group): Conventional dental implant (group Imp1) two-piece implant design, where the surgical implant and prosthetic abutment are two separate components and, the one-piece implant (group Imp2), where the surgical implant and prosthetic abutment are one integral piece. All samples were subjected to quasi-static loading at a 30° angle to the implant axis in a universal testing machine. The mean fracture strengths were 1269.2 ± 128.8 N for the group Imp1 and, 1259.5 ± 115.1 N for the group Imp2, without statistical differences (P = .8722). In both groups, the fracture surface does not present crack between the compact core and the superficial (less dense and porous) part of the implants. Based on the measured resistance data for the two implant models manufactured by direct metal laser sintering tested in the present study, we can suggest that they have adequate capacity to withstand the masticatory loads. © 2018 Wiley Periodicals, Inc.

  13. Mandibular implant-supported overdentures: attachment systems, and number and locations of implants--Part I.

    PubMed

    Warreth, Abdulhadi; Alkadhimi, Aslam Fadel; Sultan, Ahmed; Byrne, Caroline; Woods, Edel

    2015-01-01

    The use of dental implants in replacing missing teeth is an integral part of restorative dental treatment. Use of conventional complete dentures is associated with several problems such as lack of denture stability, support and retention. However, when mandibular complete dentures were used with two or more implants, an improvement in the patients' psychological and social well-being could be seen. There is general consensus that removable implant-supported overdentures (RISOs) with two implants should be considered as the first-choice standard of care for an edentulous mandible. This treatment option necessitates the use of attachment systems that connect the complete denture to the implant. Nevertheless, each attachment system has its inherent advantages and disadvantages, which should be considered when choosing a system. The first part of this article provides an overview on options available to restore the mandibular edentulous arch with dental implants. Different types of attachment systems, their features and drawbacks are also reviewed.

  14. Implant-retained maxillary overdentures.

    PubMed

    Eckert, Steven E; Carr, Alan B

    2004-07-01

    Overdentures supported by osseointegrated implants overcome many of the complications observed with overdentures supported by natural teeth. Dental implants are free of biologic consequences associated with natural teeth, such as dental caries and periodontal disease. Bone undercuts adjacent to implants do not mimic those found adjacent to natural tooth roots. Implants are used to provide predictable retention, support, and stability for overdenture prostheses. When lip or facial support is required, the overdenture is the treatment of choice. Likewise the overdenture may improve phonetic deficiencies associated with alveolar bone loss.

  15. Efficiency of Nanotube Surface-Treated Dental Implants Loaded with Doxycycline on Growth Reduction of Porphyromonas gingivalis.

    PubMed

    Ferreira, Cimara Fortes; Babu, Jegdish; Hamlekhan, Azhang; Patel, Sweetu; Shokuhfar, Tolou

    The prevalence of peri-implant infection in patients with dental implants has been shown to range from 28% to 56%. A nanotube-modified implant surface can deliver antibiotics locally and suppress periodontal pathogenic bacterial growth. The aim of this study was to evaluate the deliverability of antibiotics via a nanotube-modified implant. Dental implants with a nanotube surface were fabricated and loaded with doxycycline. Afterward, each dental implant with a nanotube surface was placed into 2-mL tubes, removed from solution, and placed in a fresh solution daily for 28 days. Experimental samples from 1, 2, 4, 16, 24, and 28 days were used for this evaluation. The concentration of doxycycline was measured using spectrophotometric analysis at 273-nm absorbance. The antibacterial effect of doxycycline was evaluated by supplementing Porphyromonas gingivalis (P gingivalis) growth media with the solution collected from the dental implants at the aforementioned time intervals for a period of 48 hours under anaerobic conditions. A bacterial viability assay was used to evaluate P gingivalis growth at 550-nm absorbance. Doxycycline concentration varied from 0.33 to 1.22 μg/mL from day 1 to day 28, respectively. A bacterial viability assay showed the highest P gingivalis growth at day 1 (2 nm) and the lowest at day 4 (0.17 nm), with a gradual reduction from day 1 to day 4 of approximately 87.5%. The subsequent growth pattern was maintained and slightly increased from baseline in approximately 48.3% from day 1 to day 24. The final P gingivalis growth measured at day 28 was 29.4% less than the baseline growth. P gingivalis growth was suppressed in media supplemented with solution collected from dental implants with a nanotube surface loaded with doxycycline during a 28-day time interval.

  16. Floor-of-Mouth Hematoma Following Dental Implant Placement: Literature Review and Case Presentation.

    PubMed

    Law, Catherine; Alam, Peyman; Borumandi, Farzad

    2017-11-01

    The authors provide a structured review of reported cases of floor-of-mouth hematoma during or after dental implantation and frequent causes and management and present a related case. An online search of the medical literature was conducted from 1990 through 2016. The following search terms were used: floor of mouth hematoma, sublingual hematoma, dental implant hematoma, implant in mandible, and complication of dental implant. Abstracts were screened for relevance to the aims of the review. Relevant reports in the English language were included and referenced. The articles were reviewed for patient demographics, implant location, coagulopathy, pre- or postoperative imaging, airway management, treatment of the hematoma, and management of the offending implant. The literature search identified 25 reported cases. Hemorrhage was caused by perforation of the lingual cortex in 84% of cases (n = 21). Airway obstruction resulted in emergency intubation or tracheostomy in 68% of patients (n = 17). Most cases (n = 18; 72%) required surgical management in the hospital setting. Management of the offending implant was reported inconsistently. Of 17 reported cases, 5 implants had to be removed, 9 remained in situ, and in 3 cases implant placement was abandoned. Only 1 case involved preoperative 3-dimensional (3D) imaging before implant insertion. The authors report on an additional case with a serious floor-of-mouth hematoma that required immediate surgical evacuation and hemostasis. Serious complications, such as floor-of-mouth hematoma after dental implant insertion, can occur, which could be life-threatening. Preoperative 3D imaging helps to visualize the individual mandibular shape, which could decrease the incidence of serious complications. If injury to vessels of the floor of the mouth cannot be confidently excluded, then further assessment and treatment are recommended before the patient is discharged. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones

    PubMed Central

    Kioleoglou, Ioannis; Pissiotis, Argirios

    2018-01-01

    Background The purpose of this study was to evaluate the accuracy of fitting of an implant supported screw-retained bar made on definitive casts produced by 4 different dental stone products. Material and Methods The dental stones tested were QuickRock (Protechno), FujiRock (GC), Jade Stone (Whip Mix) and Moldasynt (Heraeus). Three external hexagon implants were placed in a polyoxymethylene block. Definitive impressions were made using monophase high viscosity polyvinylsiloxane in combination with custom trays. Then, definitive models from the different types of dental stones were fabricated. Three castable cylinders with a machined non-enganging base were cast and connected with a very small quantity of PMMA to a cast bar, which was used to verify the marginal discrepancies between the abutments and the prosthetic platforms of the implants. For that purpose special software and a camera mounted on an optical microscope were used. The gap was measured by taking 10 measurements on each abutment, after the Sheffield test was applied. Twelve definitive casts were fabricated for each gypsum product and 40 measurements were performed for each cast. Mean, minimum, and maximum values were calculated. The Shapiro-Wilk test of normality was performed. Mann-Whitney test (P<.06) was used for the statistical analysis of the measurements. Results The non-parametric Kruskal-Wallis test revealed a statistically significant effect of the stone factor on the marginal discrepancy for all Sheffield test combinations: 1. Abutment 2 when screw was fastened on abutment 1 (χ2=3, df=35.33, P<0.01), 2. Abutment 3 when the screw was fastened on abutment 1 (χ2=3, df=37.74, P<0.01), 3. Abutment 1 when the screw was fastened on abutment 3 (χ2=3, df=39.79, P<0.01), 4. Abutment 2 when the screw was fastened on abutment 3 (χ2=3, df=37.26, P<0.01). Conclusions A significant correlation exists between marginal discrepancy and different dental gypsum products used for the fabrication of definitive casts for implant supported bars. The smallest marginal discrepancy was noted on implant supported bars fabricated on definitive casts made by Type III mounting stone. The biggest marginal discrepancy was noted on implant supported bars fabricated on definitive casts made by Type V dental stone. The marginal discrepancies presented on implant supported bars fabricated on definitive casts made by two types of Type IV dental stone were not significantly different. Key words:Dental implant, passive fit, dental stones, marginal discrepancy. PMID:29721227

  18. Postextraction Dental Implant in the Aesthetic Zone, Socket Shield Technique Versus Conventional Protocol.

    PubMed

    Bramanti, Ennio; Norcia, Antonio; Cicciù, Marco; Matacena, Giada; Cervino, Gabriele; Troiano, Giuseppe; Zhurakivska, Khrystyna; Laino, Luigi

    2018-06-01

    The aim of this randomized controlled trial was to evaluate the survival rate, the marginal bone level, and the aesthetic outcome; at 3 years' follow-up, of dental implants placed into a high-esthetic aesthetic zone by comparing 2 techniques of postextraction implant with immediate loading: the socket shied technique and the conventional insertion technique.Several clinical studies suggested that the avulsion of a dental element causes dimensional alterations of both soft and hard tissues at the postextractive site. To increase the aesthetic outcomes, the "socket-shield technique" has been proposed. This method involves maintaining the vestibular root portion and immediate insertion of the dental implant in close proximity to the root.Patients enrolled in this study were randomized to receive a postextraction implant in the aesthetic zone, either with the socket shied technique or with the conventional insertion technique. Implant survival, marginal bone level, and the pink aesthetic score were the outcomes evaluated.Implant survival rate was 100% in both the groups at 3 years. Implants inserted with the socket shield technique showed better values of both marginal bone level and pink aesthetic score (P < 0.05).Although such preliminary results need to be further confirmed, the socket shield technique seems to be a safe surgical technique that allows an implant rehabilitation characterized by better aesthetic outcomes.

  19. Investigational Clinical Trial of a Prototype Optoelectronic Computer-Aided Navigation Device for Dental Implant Surgery.

    PubMed

    Jokstad, Asbjørn; Winnett, Brenton; Fava, Joseph; Powell, David; Somogyi-Ganss, Eszter

    New digital technologies enable real-time computer-aided (CA) three-dimensional (3D) guidance during dental implant surgery. The aim of this investigational clinical trial was to demonstrate the safety and effectiveness of a prototype optoelectronic CA-navigation device in comparison with the conventional approach for planning and effecting dental implant surgery. Study participants with up to four missing teeth were recruited from the pool of patients referred to the University of Toronto Graduate Prosthodontics clinic. The first 10 participants were allocated to either a conventional or a prototype device study arm in a randomized trial. The next 10 participants received implants using the prototype device. All study participants were restored with fixed dental prostheses after 3 (mandible) or 6 (maxilla) months healing, and monitored over 12 months. The primary outcome was the incidence of any surgical, biologic, or prosthetic adverse events or device-related complications. Secondary outcomes were the incidence of positioning of implants not considered suitable for straightforward prosthetic restoration (yes/no); the perception of the ease of use of the prototype device by the two oral surgeons, recorded by use of a Likert-type questionnaire; and the clinical performance of the implant and superstructure after 1 year in function. Positioning of the implants was appraised on periapical radiographs and clinical photographs by four independent blinded examiners. Peri-implant bone loss was measured on periapical radiographs by a blinded examiner. No adverse events occurred related to placing any implants. Four device-related complications led to a switch from using the prototype device to the conventional method. All implants placed by use of the prototype device were in a position considered suitable for straightforward prosthetic restoration (n = 21). The qualitative evaluation by the surgeons was generally positive, although ergonomic challenges were identified. All study participants were present for the 1-year examination (n = 20 patients, 41 implants, 32 superstructures), and no complications or failures with any implants or superstructures were revealed. The peri-implant bone loss was less than 1 mm for all implants. Within the limitations of this trial, the prototype device provided placement of dental implants without adverse events.

  20. Bioactivity and Osseointegration of PEEK Are Inferior to Those of Titanium: A Systematic Review.

    PubMed

    Najeeb, Shariq; Bds, Zohaib Khurshid; Bds, Sana Zohaib; Bds, Muhammad Sohail Zafar

    2016-12-01

    Polyetheretherketone (PEEK) has been suggested as an alternative to replace titanium as a dental implant material. However, PEEK's bioactivity and osseointegration are debatable. This review has systematically analyzed studies that have compared PEEK (or PEEK-based) implants with titanium implants so that its feasibility as a possible replacement for titanium can be determined. The focused question was: "Are the bioactivity and osseointegration of PEEK implants comparable to or better than titanium implants?" Using the key words "dental implant," "implant," "polyetheretherketone," "PEEK," and "titanium" in various combinations, the following databases were searched electronically: PubMED/MEDLINE, Embase, Google Scholar, ISI Web of Knowledge, and Cochrane Database. 5 in vitro and 4 animal studies were included in the review. In 4 out of 5 in vitro studies, titanium exhibited more cellular proliferation, angiogenesis, osteoblast maturation, and osteogenesis compared to PEEK; one in vitro study observed comparable outcomes regardless of the implant material. In all animal studies, uncoated and coated titanium exhibited a more osteogenic behavior than did uncoated PEEK, while comparable bone-implant contact was observed in HA-coated PEEK and coated titanium implants. Unmodified PEEK is less osseoconductive and bioactive than titanium. Furthermore, the majority of studies had multiple sources of bias; hence, in its unmodified form, PEEK is unsuitable to be used as dental implant. Significantly more research and long-term trials must focus on improving the bioactivity of PEEK before it can be used as dental implant. More comparative animal and clinical studies are warranted to ascertain the potential of PEEK as a viable alternative to titanium.

  1. Two-stage implant placement technique for the management of irradiated jaws: An animal study.

    PubMed

    Aboushelib, Moustafa N; Arnaout, Mohamed A; Elsafi, Mohamed H; Kassem, Youssef M

    2017-10-01

    Radiotherapy results in diminished bone remodeling capacity and an elevated risk of osteoradionecrosis, which can negatively influence the survival rate of dental implants. Patients receiving radiotherapy are advised not to receive dental implants during or soon after completing their radiotherapy. The purpose of this animal study was to investigate a 2-stage implant placement technique designed to diminish applied trauma on irradiated bone. Two groups of white New Zealand rabbits received radiotherapy in ascending doses (2, 4, 8 Gy), while a nonirradiated group served as control. Three weeks after completion of the last radiotherapy session, one of the irradiated groups and the control group received titanium dental implants bilaterally in the femur head. For the second irradiated group, an osteotomy was performed, and the surgical wound was left to heal for 2 weeks before implant placement. All animals were sacrificed 4 weeks after implant placement, and histomorphometric analysis was used to study bone-implant contact (n=14, α=.05). Statistical analysis revealed significantly higher (F=159, P<.001) bone-implant contact in the 2-stage (40.2 ±1.9) implant placement technique than in the immediately placed implants (21.2 ±2.3) in irradiated bone. Both of the groups had a significantly lower bone-to-implant contact ratio than the non-irradiated control (64.2 ±3.8). Within the limitations of this animal study, the 2-stage implant placement technique could be used to reduce trauma in irradiated bone and to improve wound healing around dental implants. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Implant Insertion Torque: Its Role in Achieving Primary Stability of Restorable Dental Implants.

    PubMed

    Greenstein, Gary; Cavallaro, John

    2017-02-01

    A literature review was conducted to determine the role of insertion torque in attaining primary stability of dental implants. The review is comprised of articles that discussed the amount of torque needed to achieve primary implant stability in healed ridges and fresh extraction sockets prior to immediate implant loading. Studies were appraised that addressed the effects of minimum and maximum forces that can be used to successfully place implants. The minimum torque that can be employed to attain primary stability is undefined. Forces ≥30 Ncm are routinely used to place implants into healed ridges and fresh extraction sockets prior to immediate loading of implants. Increased insertion torque (≥50 Ncm) reduces micromotion and does not appear to damage bone. In general, the healing process after implant insertion provides a degree of biologic stability that is similar whether implants are placed with high or low initial insertion torque. Primary stability is desirable when placing implants, but the absence of micromotion is what facilitates predictable implant osseointegration. Increased insertion torque helps achieve primary stability by reducing implant micromotion. Furthermore, tactile information provided by the first surgical twist drill can aid in selecting the initial insertion torque to achieve predictable stability of inserted dental implants.

  3. Heat generated during seating of dental implant fixtures.

    PubMed

    Flanagan, Dennis

    2014-04-01

    Frictional heat can be generated during seating of dental implants into a drill-prepared osteotomy. This in vitro study tested the heat generated by implant seating in dense bovine mandible ramus. A thermocouple was placed approximately 0.5 mm from the rim of the osteotomy during seating of each dental implant. Four diameters of implants were tested. The average temperature increases were 0.075°C for the 5.7-mm-diameter implant, 0.97°C for the 4.7-mm-diameter implant, 1.4°C for the 3.7-mm-diameter implant, and 8.6°C for the 2.5-mm-diameter implant. The results showed that heat was indeed generated and a small temperature rise occurred, apparently by the friction of the implant surface against the fresh-cut bone surface. Bone is a poor thermal conductor. The titanium of the implant and the steel of the handpiece are much better heat conductors. Titanium may be 70 times more heat conductive than bone. The larger diameter and displacement implant may act as a heat sink to draw away any heat produced from the friction of seating the implant at the bone-implant interface. The peak temperature duration was momentary, and not measured, but this was approximately less than 1 second. Except for the 2.5-mm-diameter implants, the temperature rises and durations were found to be below those previously deemed to be detrimental, so no clinically significant osseous damage would be expected during dental implant fixture seating of standard and large-diameter-sized implants. A 2.5-mm implant may generate detrimental heat during seating in nonvital bone, but this may be clinically insignificant in vital bone. The surface area and thermal conductivity are important factors in removing generated heat transfer at the bone-implant interface. The F value as determined by analysis of variance was 69.22, and the P value was less than .0001, demonstrating significant differences between the groups considered as a whole.

  4. Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease.

    PubMed

    Kim, Dae-Hyun; Kim, Hyun Ju; Kim, Sungtae; Koo, Ki-Tae; Kim, Tae-Il; Seol, Yang-Jo; Lee, Yong-Moo; Ku, Young; Rhyu, In-Chul

    2018-04-01

    The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference ( P <0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P =0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P =0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

  5. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    PubMed

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. On the bulk degradation of yttria-stabilized nanocrystalline zirconia dental implant abutments: an electron backscatter diffraction study.

    PubMed

    Ocelík, V; Schepke, U; Rasoul, H Haji; Cune, M S; De Hosson, J Th M

    2017-08-01

    Degradation of yttria-stabilized zirconia dental implants abutments due to the tetragonal to monoclinic phase transformation was studied in detail by microstructural characterization using Electron Back Scatter Diffraction (EBSD). The amount and distribution of the monoclinic phase, the grain-size distribution and crystallographic orientations between tetragonal and monoclinic crystals in 3 mol.% yttria-stabilized polycrystalline zirconia (3Y-TZP) were determined in two different types of nano-crystalline dental abutments, even for grains smaller than 400 nm. An important and novel conclusion is that no substantial bulk degradation of 3Y-TZP dental implant abutments was detected after 1 year of clinical use.

  7. Is bruxism a risk factor for dental implants? A systematic review of the literature.

    PubMed

    Manfredini, Daniele; Poggio, Carlo E; Lobbezoo, Frank

    2014-06-01

    To systematically review the literature on the role of bruxism as a risk factor for the different complications on dental implant-supported rehabilitations. A systematic search in the National Library of Medicine's Medline Database was performed to identify all peer-reviewed papers in the English literature assessing the role of bruxism, as diagnosed with any other diagnostic approach (i.e., clinical assessment, questionnaires, interviews, polysomnography, and electromyography), as a risk factor for biological (i.e., implant failure, implant mobility, and marginal bone loss) or mechanical (i.e., complications or failures of either prefabricated components or laboratory-fabricated suprastructures) complications on dental implant-supported rehabilitations. The selected articles were reviewed according to a structured summary of the articles in relation to four main issues, viz., "P" - patients/problem/population, "I" - intervention, "C" - comparison, and "O" - outcome. A total of 21 papers were included in the review and split into those assessing biological complications (n = 14) and those reporting mechanical complications (n = 7). In general, the specificity of the literature for bruxism diagnosis and for the study of the bruxism's effects on dental implants was low. From a biological viewpoint, bruxism was not related with implant failures in six papers, while results from the remaining eight studies did not allow drawing conclusions. As for mechanical complications, four of the seven studies yielded a positive relationship with bruxism. Bruxism is unlikely to be a risk factor for biological complications around dental implants, while there are some suggestions that it may be a risk factor for mechanical complications. © 2012 Wiley Periodicals, Inc.

  8. Nanotechnology for dental implants.

    PubMed

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  9. Resonance Frequency Analysis for Osseointegration in Four Surgical Conditions of Dental Implants

    DTIC Science & Technology

    2001-10-25

    Osseointegration has been defined as “a process whereby a clinically asymptomatic rigid fixation of alloplastic materials is achieved and maintained...as the immediate implantation technique. In IIT model, the cervical third of dental implants are contacted to bone grafting materials, and apical ...Council, NSC- 89-2213-E-038-007. REFERENCES [1] Albrektsson T, Sennerby L. State of the art in oral implant. J. Clin. Periodontal . vol.18, pp. 474

  10. Life prediction of different commercial dental implants as influence by uncertainties in their fatigue material properties and loading conditions.

    PubMed

    Pérez, M A

    2012-12-01

    Probabilistic analyses allow the effect of uncertainty in system parameters to be determined. In the literature, many researchers have investigated static loading effects on dental implants. However, the intrinsic variability and uncertainty of most of the main problem parameters are not accounted for. The objective of this research was to apply a probabilistic computational approach to predict the fatigue life of three different commercial dental implants considering the variability and uncertainty in their fatigue material properties and loading conditions. For one of the commercial dental implants, the influence of its diameter in the fatigue life performance was also studied. This stochastic technique was based on the combination of a probabilistic finite element method (PFEM) and a cumulative damage approach known as B-model. After 6 million of loading cycles, local failure probabilities of 0.3, 0.4 and 0.91 were predicted for the Lifecore, Avinent and GMI implants, respectively (diameter of 3.75mm). The influence of the diameter for the GMI implant was studied and the results predicted a local failure probability of 0.91 and 0.1 for the 3.75mm and 5mm, respectively. In all cases the highest failure probability was located at the upper screw-threads. Therefore, the probabilistic methodology proposed herein may be a useful tool for performing a qualitative comparison between different commercial dental implants. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. CO2 Laser Excision of a Pyogenic Granuloma Associated with Dental Implants: A Case Report and Review of the Literature.

    PubMed

    Truschnegg, Astrid; Acham, Stephan; Kqiku, Lumnije; Beham, Alfred; Jakse, Norbert

    2016-09-01

    This article reports the CO2 laser excision of a pyogenic granuloma related to dental implants and reviews the current literature on this pathology in association with dental implants. Five publications describe pyogenic granulomas related to dental implants, and a further one describes the removal of such a lesion with an Er:YAG laser; removal with a CO2 laser is not reported. A 67-year-old male patient presented with a hyperplastic gingival lesion around two implants in the left lower jaw. The hyperplastic tissue was removed with a CO2 laser (Lasram; model OPAL 25, 25 W continuous wave, 10.600 nm, gas laser), and a vestibuloplasty was performed. The excised tissue was examined histopathologically. The patient was followed up after 4 weeks, 6 weeks, 6 months, and 1 year, and a panoramic X-ray was also made. There were no complications during surgery or follow-up. The panoramic X-ray taken 1 year after excision showed neither vertical bone loss nor impaired osseointegration of the implant. Histopathology reported a pyogenic granuloma. After vestibuloplasty, the height of the fixed mucosa was satisfactory. The CO2 laser seems to be a safe and appropriate tool for removal of a pyogenic granuloma in close proximity to dental implants. The laser parameters must, however, be chosen carefully and any additional irritants should be excluded to prevent a recurrence.

  12. Preferred Source and Perceived Need of More Information about Dental Implants by the Undergraduate Dental Students of Nepal: All Nepal Survey.

    PubMed

    Sharma, Arati; Shrestha, Bidhan; Chaudhari, Bijay Kumar; Suwal, Pramita; Singh, Raj Kumar; Niraula, Surya Raj; Parajuli, Prakash Kumar

    2018-01-01

    This study was conducted to know the preferred source and perceived need of more information about dental implants by the undergraduate students of Nepal and their association with academic levels and gender. It was conducted in all the dental colleges of Nepal from June 2016 to June 2017 after taking ethical clearance and approval from the research committee of BPKIHS. It included all those who were present at the time of survey. Data collection was done through a cross-sectional questionnaire survey during the academic schedule of the colleges, supervised and monitored by the investigators themselves. The collected data were coded and entered in Microsoft excel 2013, and statistical analysis was done by SPSS 20 version. A majority of the respondents agreed that they were not provided with sufficient information about implant treatment procedures during their BDS program (65.3%), would like more to be provided in the curriculum (95.1%), and would like to get additional reliable information from dental consultants and specialists (40.7%) and training on it from fellowship programs conducted by universities (39.2%). Significant association was seen between the responses and academic levels. Undergraduate dental students of Nepal want more information about dental implants through various means.

  13. Preferred Source and Perceived Need of More Information about Dental Implants by the Undergraduate Dental Students of Nepal: All Nepal Survey

    PubMed Central

    Shrestha, Bidhan; Chaudhari, Bijay Kumar; Singh, Raj Kumar; Niraula, Surya Raj; Parajuli, Prakash Kumar

    2018-01-01

    Objectives This study was conducted to know the preferred source and perceived need of more information about dental implants by the undergraduate students of Nepal and their association with academic levels and gender. Materials and Methods It was conducted in all the dental colleges of Nepal from June 2016 to June 2017 after taking ethical clearance and approval from the research committee of BPKIHS. It included all those who were present at the time of survey. Data collection was done through a cross-sectional questionnaire survey during the academic schedule of the colleges, supervised and monitored by the investigators themselves. The collected data were coded and entered in Microsoft excel 2013, and statistical analysis was done by SPSS 20 version. Result A majority of the respondents agreed that they were not provided with sufficient information about implant treatment procedures during their BDS program (65.3%), would like more to be provided in the curriculum (95.1%), and would like to get additional reliable information from dental consultants and specialists (40.7%) and training on it from fellowship programs conducted by universities (39.2%). Significant association was seen between the responses and academic levels. Conclusion Undergraduate dental students of Nepal want more information about dental implants through various means. PMID:29713346

  14. Management of Patients With Cardiovascular Implantable Electronic Devices in Dental, Oral, and Maxillofacial Surgery.

    PubMed

    Tom, James

    2016-01-01

    The prevalence of cardiovascular implantable electronic devices as life-prolonging and life-saving devices has evolved from a treatment of last resort to a first-line therapy for an increasing number of patients. As these devices become more and more popular in the general population, dental providers utilizing instruments and medications should be aware of dental equipment and medications that may affect these devices and understand the management of patients with these devices. This review article will discuss the various types and indications for pacemakers and implantable cardioverter-defibrillators, common drugs and instruments affecting these devices, and management of patients with these devices implanted for cardiac dysrhythmias.

  15. Management of Patients With Cardiovascular Implantable Electronic Devices in Dental, Oral, and Maxillofacial Surgery

    PubMed Central

    Tom, James

    2016-01-01

    The prevalence of cardiovascular implantable electronic devices as life-prolonging and life-saving devices has evolved from a treatment of last resort to a first-line therapy for an increasing number of patients. As these devices become more and more popular in the general population, dental providers utilizing instruments and medications should be aware of dental equipment and medications that may affect these devices and understand the management of patients with these devices. This review article will discuss the various types and indications for pacemakers and implantable cardioverter-defibrillators, common drugs and instruments affecting these devices, and management of patients with these devices implanted for cardiac dysrhythmias. PMID:27269668

  16. Imunohistological aspects of the tissue around dental implants

    NASA Astrophysics Data System (ADS)

    Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru

    2016-03-01

    Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.

  17. Dental Implant Complications.

    PubMed

    Liaw, Kevin; Delfini, Ronald H; Abrahams, James J

    2015-10-01

    Dental implants have increased in the last few decades thus increasing the number of complications. Since many of these complications are easily diagnosed on postsurgical images, it is important for radiologists to be familiar with them and to be able to recognize and diagnose them. Radiologists should also have a basic understanding of their treatment. In a pictorial fashion, this article will present the basic complications of dental implants which we have divided into three general categories: biomechanical overload, infection or inflammation, and other causes. Examples of implant fracture, loosening, infection, inflammation from subgingival cement, failure of bone and soft tissue preservation, injury to surround structures, and other complications will be discussed as well as their common imaging appearances and treatment. Lastly, we will review pertinent dental anatomy and important structures that are vital for radiologists to evaluate in postoperative oral cavity imaging. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Experimental and computational investigation of Morse taper conometric system reliability for the definition of fixed connections between dental implants and prostheses.

    PubMed

    Bressan, Eriberto; Lops, Diego; Tomasi, Cristiano; Ricci, Sara; Stocchero, Michele; Carniel, Emanuele Luigi

    2014-07-01

    Nowadays, dental implantology is a reliable technique for treatment of partially and completely edentulous patients. The achievement of stable dentition is ensured by implant-supported fixed dental prostheses. Morse taper conometric system may provide fixed retention between implants and dental prostheses. The aim of this study was to investigate retentive performance and mechanical strength of a Morse taper conometric system used as implant-supported fixed dental prostheses retention. Experimental and finite element investigations were performed. Experimental tests were achieved on a specific abutment-coping system, accounting for both cemented and non-cemented situations. The results from the experimental activities were processed to identify the mechanical behavior of the coping-abutment interface. Finally, the achieved information was applied to develop reliable finite element models of different abutment-coping systems. The analyses were developed accounting for different geometrical conformations of the abutment-coping system, such as different taper angle. The results showed that activation process, occurred through a suitable insertion force, could provide retentive performances equal to a cemented system without compromising the mechanical functionality of the system. These findings suggest that Morse taper conometrical system can provide a fixed connection between implants and dental prostheses if proper insertion force is applied. Activation process does not compromise the mechanical functionality of the system. © IMechE 2014.

  19. Interventions for replacing missing teeth: antibiotics at dental implant placement to prevent complications.

    PubMed

    Esposito, Marco; Worthington, Helen V; Loli, Vassiliki; Coulthard, Paul; Grusovin, Maria Gabriella

    2010-07-07

    Some dental implant failures may be due to bacterial contamination at implant insertion. Infections around biomaterials are difficult to treat and almost all infected implants have to be removed. In general, antibiotic prophylaxis in surgery is only indicated for patients at risk of infectious endocarditis, for patients with reduced host-response, when surgery is performed in infected sites, in cases of extensive and prolonged surgical interventions and when large foreign materials are implanted. To minimise infections after dental implant placement various prophylactic systemic antibiotic regimens have been suggested. More recent protocols recommended short term prophylaxis, if antibiotics have to be used. With the administration of antibiotics adverse events may occur, ranging from diarrhoea to life-threatening allergic reactions. Another major concern associated with the widespread use of antibiotics is the selection of antibiotic-resistant bacteria. The use of prophylactic antibiotics in implant dentistry is controversial. To assess the beneficial or harmful effects of systemic prophylactic antibiotics at dental implant placement versus no antibiotic/placebo administration and, if antibiotics are of benefit, to find which type, dosage and duration is the most effective. The Cochrane Oral Health Group's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE were searched up to 2nd June 2010. Several dental journals were handsearched. There were no language restrictions. Randomised controlled clinical trials (RCTs) with a follow up of at least 3 months comparing the administration of various prophylactic antibiotic regimens versus no antibiotics to patients undergoing dental implant placement. Outcome measures were prosthesis failures, implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc). Screening of eligible studies, assessment of the methodological quality of the trials and data extraction were conducted in duplicate and independently by two review authors. Results were expressed as random-effects models using risk ratios (RRs) for dichotomous outcomes with 95% confidence intervals (CIs). Heterogeneity was to be investigated including both clinical and methodological factors. Four RCTs were identified: three comparing 2 g of preoperative amoxicillin versus placebo (927 patients) and the other comparing 1 g of preoperative amoxicillin plus 500 mg 4 times a day for 2 days versus no antibiotics (80 patients). The meta-analyses of the four trials showed a statistically significant higher number of patients experiencing implant failures in the group not receiving antibiotics: RR = 0.40 (95% CI 0.19 to 0.84). The number needed to treat (NNT) to prevent one patient having an implant failure is 33 (95% CI 17 to 100), based on a patient implant failure rate of 5% in patients not receiving antibiotics. The other outcomes were not statistically significant, and only two minor adverse events were recorded, one in the placebo group. There is some evidence suggesting that 2 g of amoxicillin given orally 1 hour preoperatively significantly reduce failures of dental implants placed in ordinary conditions. No significant adverse events were reported. It might be sensible to suggest the use of a single dose of 2 g prophylactic amoxicillin prior to dental implant placement. It is still unknown whether postoperative antibiotics are beneficial, and which is the most effective antibiotic.

  20. Clinical outcomes of implant therapy in ectodermal dysplasia patients: a systematic review.

    PubMed

    Wang, Y; He, J; Decker, A M; Hu, J C; Zou, D

    2016-08-01

    The purpose of this review was to determine the outcome of oral function reconstruction in ectodermal dysplasia (ED) patients who have received dental implant therapy. A search was made of the PubMed and Web of Science databases; key words used were "(ectodermal dysplasia) AND (implant OR implants)", with supplementary retrieval key words "dental implant", "zygomatic implant", "anodontia", and "edentulous". Patient age, use of bone graft, implant site, type of implant, and survival rate of the implants were included in the subsequent data analysis. Forty-five articles published between 1988 and October 2015 were included in this analysis. The cases of a total of 96 patients were retrieved (22 children and 74 adults); these patients received a total of 701 implants. Fourteen implants were removed during a median follow-up time of 24 months. The 24-month implant survival rate was 97.9% in adult subjects and 98.6% in children. Sixty-eight percent of adult patients underwent bone augmentation prior to implant placement. Based on this review, dental implants are commonly used in the oral reconstruction of ED patients. However, long-term data on bone augmentation and implant success are needed, as well as additional clinical evidence on bone resorption, the esthetic outcomes of implant therapy, and physiological considerations in ED patients. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Quantification of dental prostheses on cone‐beam CT images by the Taguchi method

    PubMed Central

    Kuo, Rong‐Fu; Fang, Kwang‐Ming; TY, Wong

    2016-01-01

    The gray values accuracy of dental cone‐beam computed tomography (CBCT) is affected by dental metal prostheses. The distortion of dental CBCT gray values could lead to inaccuracies of orthodontic and implant treatment. The aim of this study was to quantify the effect of scanning parameters and dental metal prostheses on the accuracy of dental cone‐beam computed tomography (CBCT) gray values using the Taguchi method. Eight dental model casts of an upper jaw including prostheses, and a ninth prosthesis‐free dental model cast, were scanned by two dental CBCT devices. The mean gray value of the selected circular regions of interest (ROIs) were measured using dental CBCT images of eight dental model casts and were compared with those measured from CBCT images of the prosthesis‐free dental model cast. For each image set, four consecutive slices of gingiva were selected. The seven factors (CBCTs, occlusal plane canting, implant connection, prosthesis position, coping material, coping thickness, and types of dental restoration) were used to evaluate scanning parameter and dental prostheses effects. Statistical methods of signal to noise ratio (S/N) and analysis of variance (ANOVA) with 95% confidence were applied to quantify the effects of scanning parameters and dental prostheses on dental CBCT gray values accuracy. For ROIs surrounding dental prostheses, the accuracy of CBCT gray values were affected primarily by implant connection (42%), followed by type of restoration (29%), prostheses position (19%), coping material (4%), and coping thickness (4%). For a single crown prosthesis (without support of implants) placed in dental model casts, gray value differences for ROIs 1–9 were below 12% and gray value differences for ROIs 13–18 away from prostheses were below 10%. We found the gray value differences set to be between 7% and 8% for regions next to a single implant‐supported titanium prosthesis, and between 46% and 59% for regions between double implant‐supported, nickel‐chromium alloys (Ni‐Cr) prostheses. Quantification of the effect of prostheses and scanning parameters on dental CBCT gray values was assessed. PACS numbers: 87.59.bd, 87.57Q PMID:26894354

  2. To reduce the maximum stress and the stress shielding effect around a dental implant-bone interface using radial functionally graded biomaterials.

    PubMed

    Asgharzadeh Shirazi, H; Ayatollahi, M R; Asnafi, A

    2017-05-01

    In a dental implant system, the value of stress and its distribution plays a pivotal role on the strength, durability and life of the implant-bone system. A typical implant consists of a Titanium core and a thin layer of biocompatible material such as the hydroxyapatite. This coating has a wide range of clinical applications in orthopedics and dentistry due to its biocompatibility and bioactivity characteristics. Low bonding strength and sudden variation of mechanical properties between the coating and the metallic layers are the main disadvantages of such common implants. To overcome these problems, a radial distributed functionally graded biomaterial (FGBM) was proposed in this paper and the effect of material property on the stress distribution around the dental implant-bone interface was studied. A three-dimensional finite element simulation was used to illustrate how the use of radial FGBM dental implant can reduce the maximum von Mises stress and, also the stress shielding effect in both the cortical and cancellous bones. The results, of course, give anybody an idea about optimized behaviors that can be achieved using such materials. The finite element solver was validated by familiar methods and the results were compared to previous works in the literature.

  3. Three tumor patients with total maxillectomy rehabilitated with implant-supported frameworks and maxillary obturators: a follow-up report.

    PubMed

    Örtorp, Anders

    2010-12-01

    Few reports are available on treatment using implant-supported frameworks with maxillary obturators after total maxillectomy on tumor patients. To describe, evaluate, and report the clinical and radiographic performance of implant-supported frameworks and maxillary obturators after maxillectomy during the first years of function. Three patients with cancer in the maxillary region treated by total maxillectomy were rehabilitated. Seventeen dental and two craniofacial implants were installed, and the patients each received implant-supported, screw-retained, three-unit frameworks with a U-shaped bar and obturators retained by four magnetic attachments. Clinical and radiographic data were collected up to 7 years of follow-up. The frequency of complications was low. Two craniofacial implants and one dental implant were loose and removed at abutment connection. No implants were lost after framework connection, and the mean marginal bone loss was small. Within the limitations of this report, dental implants are useful for rehabilitation of total maxillectomy patients, and a three-unit, screw-retained, implant-supported framework with maxillary obturator retained by magnetic attachment is a successful treatment concept for this patient group. © 2009, Copyright the Author. Journal Compilation © 2010, Wiley Periodicals, Inc.

  4. The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study.

    PubMed

    Pagliani, L; Sennerby, L; Petersson, A; Verrocchi, D; Volpe, S; Andersson, P

    2013-03-01

    This in vitro investigation was conducted to study the relationship between resonance frequency analysis (RFA) and lateral displacement measurements of dental implants. A total of 30 implant sites were prepared in nine fresh bovine bone specimens. The bone density around each preparation was determined by using cone beam computerized tomography (CBCT) and imaging software. Dental implants were then inserted during continuous registration of insertion torque. RFA measurements were performed in perpendicular and parallel to the long axis of the specimens. The bone blocks were embedded in plaster and fixated in a specially designed rig for displacement measurements. A lateral force of 25 N was applied via an abutment perpendicular and parallel to each implant and the displacement measured in μm. In addition, a flex constant (μm N(-1) ) was calculated for each measurement. There was a significant inverse correlation between RFA and lateral implant displacement (μm) measurements and between RFA measurements and the flex constant in both perpendicular and parallel directions in bone (P ≤ 0·001). Moreover, both RFA and displacement measurements correlated with bone density (P ≤ 0·001). It is concluded that RFA measurements reflect the micromobility of dental implants, which in turn is determined by the bone density at the implant site. © 2012 Blackwell Publishing Ltd.

  5. [Manufacture method and clinical application of minimally invasive dental implant guide template based on registration technology].

    PubMed

    Lin, Zeming; He, Bingwei; Chen, Jiang; D u, Zhibin; Zheng, Jingyi; Li, Yanqin

    2012-08-01

    To guide doctors in precisely positioning surgical operation, a new production method of minimally invasive implant guide template was presented. The mandible of patient was scanned by CT scanner, and three-dimensional jaw bone model was constructed based on CT images data The professional dental implant software Simplant was used to simulate the plant based on the three-dimensional CT model to determine the location and depth of implants. In the same time, the dental plaster models were scanned by stereo vision system to build the oral mucosa model. Next, curvature registration technology was used to fuse the oral mucosa model and the CT model, then the designed position of implant in the oral mucosa could be determined. The minimally invasive implant guide template was designed in 3-Matic software according to the design position of implant and the oral mucosa model. Finally, the template was produced by rapid prototyping. The three-dimensional registration technology was useful to fuse the CT data and the dental plaster data, and the template was accurate that could provide the doctors a guidance in the actual planting without cut-off mucosa. The guide template which fabricated by comprehensive utilization of three-dimensional registration, Simplant simulation and rapid prototyping positioning are accurate and can achieve the minimally invasive and accuracy implant surgery, this technique is worthy of clinical use.

  6. Minimum intervention dentistry: periodontics and implant dentistry.

    PubMed

    Darby, I B; Ngo, L

    2013-06-01

    This article will look at the role of minimum intervention dentistry in the management of periodontal disease. It will discuss the role of appropriate assessment, treatment and risk factors/indicators. In addition, the role of the patient and early intervention in the continuing care of dental implants will be discussed as well as the management of peri-implant disease. © 2013 Australian Dental Association.

  7. Mechanical assessment of grit blasting surface treatments of dental implants.

    PubMed

    Shemtov-Yona, K; Rittel, D; Dorogoy, A

    2014-11-01

    This paper investigates the influence of surface preparation treatments of dental implants on their potential (mechanical) fatigue failure, with emphasis on grit-blasting. The investigation includes limited fatigue testing of implants, showing the relationship between fatigue life and surface damage condition. Those observations are corroborated by a detailed failure analysis of retrieved fracture dental implants. In both cases, the negative effect of embedded alumina particles related to the grit-blasting process is identified. The study also comprises a numerical simulation part of the grit blasting process that reveals, for a given implant material and particle size, the existence of a velocity threshold, below which the rough surface is obtained without damage, and beyond which the creation of significant surface damage will severely reduce the fatigue life, thus increasing fracture probability. The main outcome of this work is that the overall performance of dental implants comprises, in addition to the biological considerations, mechanical reliability aspects. Fatigue fracture is a central issue, and this study shows that uncontrolled surface roughening grit-blasting treatments can induce significant surface damage which accelerate fatigue fracture under certain conditions, even if those treatments are beneficial to the osseointegration process. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Relationship between Sponsorship and Failure Rate of Dental Implants: A Systematic Approach

    PubMed Central

    Popelut, Antoine; Valet, Fabien; Fromentin, Olivier; Thomas, Aurélie; Bouchard, Philippe

    2010-01-01

    Background The number of dental implant treatments increases annually. Dental implants are manufactured by competing companies. Systematic reviews and meta-analysis have shown a clear association between pharmaceutical industry funding of clinical trials and pro-industry results. So far, the impact of industry sponsorship on the outcomes and conclusions of dental implant clinical trials has never been explored. The aim of the present study was to examine financial sponsorship of dental implant trials, and to evaluate whether research funding sources may affect the annual failure rate. Methods and Findings A systematic approach was used to identify systematic reviews published between January 1993 and December 2008 that specifically deal with the length of survival of dental implants. Primary articles were extracted from these reviews. The failure rate of the dental implants included in the trials was calculated. Data on publication year, Impact Factor, prosthetic design, periodontal status reporting, number of dental implants included in the trials, methodological quality of the studies, presence of a statistical advisor, and financial sponsorship were extracted by two independent reviewers (kappa  = 0.90; CI95% [0.77–1.00]). Univariate quasi-Poisson regression models and multivariate analysis were used to identify variables that were significantly associated with failure rates. Five systematic reviews were identified from which 41 analyzable trials were extracted. The mean annual failure rate estimate was 1.09%.(CI95% [0.84–1.42]). The funding source was not reported in 63% of the trials (26/41). Sixty-six percent of the trials were considered as having a risk of bias (27/41). Given study age, both industry associated (OR = 0.21; CI95% [0.12–0.38]) and unknown funding source trials (OR = 0.33; (CI95% [0.21–0.51]) had a lower annual failure rates compared with non-industry associated trials. A conflict of interest statement was disclosed in 2 trials. Conclusions When controlling for other factors, the probability of annual failure for industry associated trials is significantly lower compared with non-industry associated trials. This bias may have significant implications on tooth extraction decision making, research on tooth preservation, and governmental health care policies. PMID:20422000

  9. Atomic force microscopy analysis of different surface treatments of Ti dental implant surfaces

    NASA Astrophysics Data System (ADS)

    Bathomarco, Ti R. V.; Solorzano, G.; Elias, C. N.; Prioli, R.

    2004-06-01

    The surface of commercial unalloyed titanium, used in dental implants, was analyzed by atomic force microscopy. The morphology, roughness, and surface area of the samples, submitted to mechanically-induced erosion, chemical etching and a combination of both, were compared. The results show that surface treatments strongly influence the dental implant physical and chemical properties. An analysis of the length dependence of the implant surface roughness shows that, for scan sizes larger than 50 μm, the average surface roughness is independent of the scanning length and that the surface treatments lead to average surface roughness in the range of 0.37 up to 0.48 μm. It is shown that the implant surface energy is sensitive to the titanium surface area. As the area increases there is a decrease in the surface contact angle.

  10. Assessment of the Survival of Dental Implants in Irradiated Jaws Following Treatment of Oral Cancer: A Retrospective Study

    PubMed Central

    Rana, Meenakshi Chauhan; Solanki, Swati; Pujari, Sudarshan C; Shaw, Eisha; Sharma, Swati; Anand, Abhishek; Singh, Harkanwal Preet

    2016-01-01

    Background: In patients undergoing head and neck surgery for various pathologic conditions, implants are one of the best restorative options and are increasing widely used. Therefore, we evaluated the success of dental implants in the irradiated jaws of patients following treatment of oral cancer oral cancer treated patients. Materials and Methods: Data of oral cancer treated patients was collected retrospectively from 2002 to 2008. We took 46 oral cancer treated patients in which implants were placed in irradiated jaws for rehabilitation. Results: It was found that out of 162 dental implants placed, 52 failed. Furthermore, there was no variation in the implant survival rate in between both the jaws. Radiation dose of <50 Gy units also showed significantly increased amount of implant survival rate. Conclusions: Implant survival is multifactorial and depends upon a number of factors like level of radiation exposure in that area, time gap between last radiation doses etc., Further research is required in this field to improve the esthetics and quality of life of cancer treated patients. PMID:27843270

  11. Outcomes of Dental Implant Therapy in Patients With Down Syndrome: A Systematic Review.

    PubMed

    Najeeb, Shariq; Khurshid, Zohaib; Siddiqui, Fahad; Zohaib, Sana; Zafar, Muhammad Sohail

    2017-12-01

    Patients with Down syndrome (DS) require an earlier and more frequent tooth replacement than rest of the population. The objective of this systematic review is to critically analyze and summarize studies to ascertain the outcomes and survival of dental implants placed in jaws of DS patients. Using the key words "dental implants," "Down syndrome," and "prosthodontics," an electronic search was conducted via PubMed/MEDLINE, ISI Web of Science, Google Scholar, Embase, and Central Register of Controlled Trials (CENTRAL) databases by 2 authors, S.N. and Z.K., independently. Retrieved studies were screened against the predefined exclusion and inclusion criteria. To estimate the risk of bias, quality assessment of included studies was carried using the 'Case Reports (CARE) guidelines'. Primary search resulted in 156 studies. Eight studies met the inclusion criteria and reporting a total of 81 dental implants placed in 36 DS patients. The type of implant loading ranged from immediate to a delay of 1 year after placement of the implant. Implant diameter ranged from 3.3 to 4.5 mm, and height ranged from 8.5 to 18 mm. The follow-up ranged from 1 to 6 years. Of 81 implants placed, 21 implants (26%) were reported as failed. Patients with DS have a higher risk of implant failure. However, the reason for the failure is not very well understood. Although case reports and case series suggest that implant survival is diminished in DS patients, large-scale randomized controlled trials are required to determine the exact mechanism associated with risks of implant failure. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Metal elements in tissue with dental peri-implantitis: a pilot study.

    PubMed

    Fretwurst, Tobias; Buzanich, Guenter; Nahles, Susanne; Woelber, Johan Peter; Riesemeier, Heinrich; Nelson, Katja

    2016-09-01

    Dental peri-implantitis is characterized by a multifactorial etiology. The role of metal elements as an etiological factor for peri-implantitis is still unclear. The aim of this study was to investigate the incidence of metal elements in bone and mucosal tissues around dental Grade 4 CP titanium implants with signs of peri-implantitis in human patients. In this prospective pilot study, all patients were enrolled consecutively in two study centers. Bone and soft tissue samples of patients with peri-implantitis with indication for explantation were analyzed for the incidence of different elements (Ca, P, Ti, Fe) by means of synchrotron radiation X-ray fluorescence spectroscopy (SRXRF) and polarized light microscopy (PLM). The existence of macrophages and lymphocytes in the histologic specimens was analyzed. Biopsies of 12 patients (seven bone samples, five mucosal samples) were included and analyzed. In nine of the 12 samples (75%), the SRXRF examination revealed the existence of titanium (Ti) and an associated occurrence with Iron (Fe). Metal particles were detected in peri-implant soft tissue using PLM. In samples with increased titanium concentration, lymphocytes were detected, whereas M1 macrophages were predominantly seen in samples with metal particles. Titanium and Iron elements were found in soft and hard tissue biopsies retrieved from peri-implantitis sites. Further histologic and immunohistochemical studies need to clarify which specific immune reaction metal elements/particles induce in dental peri-implant tissue. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Electromagnetic interference of dental equipment with implantable cardioverter defibrillators.

    PubMed

    Dadalti, Manoela Teixeira de Sant'Anna; da Cunha, Antônio José Ledo Alves; Araújo, Marcos César Pimenta de; Moraes, Luis Gustavo Belo de; Risso, Patrícia de Andrade

    2017-11-01

    Implantable cardioverter defibrillators (ICDs) are subject to electromagnetic interference (EMI). The aim of this study was to assess both the EMI of dental equipments with ICDs and related factors. High- and low-speed handpieces, an electric toothbrush, an implant motor and two types of ultrasonic devices were tested next to an ICD with different sensitivity settings. The ICD was immersed in a saline solution with electrical resistance of 400-800 ohms to simulate the resistance of the human body. The dental equipments were tested in both horizontal (0°) and vertical (90°) positions in relation to the components of the ICD. The tests were performed with a container containing saline solution, which was placed on a dental chair in order to assess the cumulative effect of electromagnetic fields. The dental chair, high- and low-speed handpieces, electric toothbrush, implant motor and ultrasonic devices caused no EMI with the ICD, irrespective of the program set-up or positioning. No cumulative effect of electromagnetic fields was verified. The results of this study suggest that the devices tested are safe for use in patients with an ICD.

  14. Digital data acquisition for a CAD/CAM-fabricated titanium framework and zirconium oxide restorations for an implant-supported fixed complete dental prosthesis.

    PubMed

    Lin, Wei-Shao; Metz, Michael J; Pollini, Adrien; Ntounis, Athanasios; Morton, Dean

    2014-12-01

    This dental technique report describes a digital workflow with digital data acquisition at the implant level, computer-aided design and computer-aided manufacturing fabricated, tissue-colored, anodized titanium framework, individually luted zirconium oxide restorations, and autopolymerizing injection-molded acrylic resin to fabricate an implant-supported, metal-ceramic-resin fixed complete dental prosthesis in an edentulous mandible. The 1-step computer-aided design and computer-aided manufacturing fabrication of titanium framework and zirconium oxide restorations can provide a cost-effective alternative to the conventional metal-resin fixed complete dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. OHRQoL, masticatory performance and crestal bone loss with single-implant, magnet-retained mandibular overdentures with conventional and shortened dental arch.

    PubMed

    Grover, Manita; Vaidyanathan, Anand Kumar; Veeravalli, Padmanabhan Thallam

    2014-05-01

    The aim of this study was to assess the use of single implant-supported, magnet-retained mandibular overdentures to improve the oral health-related quality of life (OHRQoL) and masticatory performance of patients wearing conventional complete dentures. The study also aimed at comparing the OHRQoL, masticatory performance, and crestal bone loss with two different types of overdenture prosthesis. Ten completely edentulous patients with atrophic mandibular residual alveolar ridges and having difficulty coping with technically adequate mandibular dentures were selected for implant-supported overdentures (ISOD). To assess the success of the implant fixture clinically, a crossover study design was followed, and the patients were divided into two groups. Group A received ISOD with conventional complete dental arch, and group B received ISOD with a shortened dental arch for the first 3 months and vice versa for the next 3 months. The OHRQoL was measured with the OHIP-49 questionnaire, and masticatory performance was assessed with the sieve method using peanuts as test food. Peri-apical radiographs were taken to evaluate the crestal bone loss. A significant improvement was seen both subjectively and objectively when conventional complete dentures were modified to implant-supported prosthesis. When comparing the implant overdenture prosthesis, patients were more satisfied with conventional arch than with the shortened dental arch. In the first 3 months following implant placement, less bone loss was seen with the shortened dental arch overdenture (P < 0.05). Single implant-supported, magnet-retained mandibular overdentures significantly improve the OHRQoL of completely edentulous patients. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  16. Hard and soft tissue surgical complications in dental implantology.

    PubMed

    Aziz, Shahid R

    2015-05-01

    This article discusses surgical complications associated with the placement of dental implants, specifically focusing on how they occur (etiology), as well as their management and prevention. Dental implant surgical complications can be classified into those of hard and soft tissues. In general, complications can be avoided with thorough preoperative treatment planning and proper surgical technique. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1979-12-01

    conventional dental materials, usually gold. Roots are produced by grinding bisque fired alumina stock on a computer controlled milling machine. This...post and core and crown) are conventional dental materials, usually gold. Roots are produced by grinding bisque fired alumina stock on a computer...of dental implants have evolved. These devices are designed to be rigidly affixed by bone ingrowth and provide minimization of stress usually by

  18. Sclerostin-neutralizing Antibody Enhances Bone Regeneration around Oral Implants.

    PubMed

    Yu, Shan Huey; Hao, Jie; Fretwurst, Tobias; Liu, Min; Kostenuik, Paul; Giannobile, William V; Jin, Qiming

    2018-06-19

    Dental implants have been an important option for the replacement of missing teeth. A major clinical challenge is how best to accelerate bone regeneration and reduce the healing time for functional restoration after implant placement. Monoclonal antibody against sclerostin (Scl-Ab) has been shown to enhance alveolar bone formation and fracture repair. The aim of this study was to investigate the effects of systemic administration of Scl-Ab on dental implant osseointegration and bone regeneration in an experimental alveolar ridge tooth extraction model. To investigate the effects of Scl-Ab on bone regeneration and dental implant osseointegration, an experimental alveolar bone osteotomy rat model was adopted. One month after the extraction of maxillary right first molars, osteotomy defects were created at the coronal aspect of each of the extraction sites, and 1x2 mm custom titanium implants were pressed-fitted into the osteotomies. Coincident with initial implant placement, Scl-Ab or vehicle was administered subcutaneously twice weekly at a dose of 25 mg/kg for 10-28 days and compared to a vehicle control. Rats were sacrificed 10, 14 and 28d after surgery, and maxillae were harvested and analyzed by micro-computed tomography (microCT), histology and histomorphometry. MicroCT analysis demonstrated that maxillary bone volume fraction was approximately 2 to 2.5-fold greater in Scl-Ab treated animals as compared to vehicle alone at days 14 and 28. Consistent with those findings, 2-D bone fill percentage within the coronal osteotomy sites were highest in Scl-Ab treatment groups at 28d. In addition, bone-implant contact at 28d was approximately 2-fold greater in the Scl-Ab group compared to vehicle controls. These results indicate that systemic Scl-Ab administration enhances osseointegration and bone regeneration around dental implants. This approach offers potential as a treatment modality for patients with low bone mass or bone defects to achieve more predictable bone regeneration at alveolar bone defects, and to enhance dental implant osseointegration.

  19. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations

    PubMed Central

    Romero, Luis; Jiménez, Mariano; Espinosa, María del Mar; Domínguez, Manuel

    2015-01-01

    Aim This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. Method From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Results Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants. PMID:26696528

  20. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations.

    PubMed

    Romero, Luis; Jiménez, Mariano; Espinosa, María Del Mar; Domínguez, Manuel

    2015-01-01

    This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants.

  1. Knowledge, aptitudes, and preferences in implant dentistry teaching/training among undergraduate dental students at the University of Barcelona

    PubMed Central

    Berástegui-Jimeno, Esther; Gay-Escoda, Cosme

    2017-01-01

    Background Oral implant rehabilitation should be considered a treatment option for any edentulous patient and Implant Dentistry is currently a discipline taught in the undergraduate formation. The level of knowledge acquired and how the students perceive the quality of training in Implant Dentistry could assess to know if it is necessary to improve the syllabus. Material and Methods A questionnaire was developed with 11 questions: Basic knowledge (7); Perception of training received (2); Ways in which students would receive training (2). To be responded anonymously and voluntarily for undergraduates students in the Faculty of Dentistry (University of Barcelona, Spain). Results One hundred and seven students, 76 third year (Group A) and 31 fourth year (Group B) answered the questionnaire. In Group A, 98.68% of students and in Group B 93.54% believed they were poorly informed; 100% of both groups would prefer to receive more training as part of the degree or as postgraduate training through modular courses imparted by experts (A: 71,05%, B: 70,96%) Training through postgraduate programs or training given by private businesses were the least desirable options (A: 42%, B: 64.51%). Questions about basic knowledge acquired received varying responses, which might indicate a certain level of confusion in this area. Conclusions The undergraduate syllabus must be revised to include sufficient content and training to allow the student to indicate implant-based treatments based on evidence. Students would prefer training to be included in the undergraduate syllabus. Key words:Dental implants, dental students, dental education, dental syllabus, implant dentistry. PMID:28578375

  2. Oral health and oral implant status in edentulous patients with implant-supported dental prostheses who are receiving long-term nursing care.

    PubMed

    Isaksson, Rita; Becktor, Jonas P; Brown, Andrew; Laurizohn, Christer; Isaksson, Sten

    2009-12-01

    The aim of this study was to investigate oral health and oral implant status in a group of edentulous patients receiving long-term residential or nursing care (LTC), all of whom had implant-supported fixed or removable dental prostheses. A dental examination was performed on a total of 3310 patients receiving LTC and from this population 35 edentulous patients in whom dental implants had been placed formed the cohort for this study. All examinations were performed by a specialist in hospital dentistry and took place in the patients' own home environment. Oral health was assessed by means of a protocol which evaluated oral hygiene status, possible oral mucosal inflammation and oral mucosal friction levels. Any problems with the implant-supported prosthesis, implant mobility or other complications were also assessed. In addition, patients were asked about any oral symptoms and their usual oral hygiene procedures. About half of the subjects (17/35) were registered as having no/mild inflammation with 18 of 35 having moderate/severe inflammation. Twelve of the 35 patients had good/acceptable oral hygiene and 23 of 35 had poor/bad oral hygiene. Twenty-one of the 35 patients depended on help from the nursing personnel for their daily oral hygiene procedures. Obvious problems with food impaction were noted in 11 patients. A total of 229 implants had been placed in 43 jaws supporting 40 full arch-fixed prostheses and three implant-borne overdentures. There was no evidence of mobility or fractures of either the implants or the prostheses. Fifteen implants showed some exposed screw threads. Pus was exuding from one implant site and general peri-implant gingival hyperplasia was noted in two patients. Twenty-four patients were completely satisfied with the function and appearance of their implant-supported prostheses. Two patients were totally dissatisfied. This study indicates that oral implant therapy can be considered as a treatment of choice in elderly patients, even if oral hygiene is sub-optimal.

  3. On stress/strain shielding and the material stiffness paradigm for dental implants.

    PubMed

    Korabi, Raoof; Shemtov-Yona, Keren; Rittel, Daniel

    2017-10-01

    Stress shielding considerations suggest that the dental implant material's compliance should be matched to that of the host bone. However, this belief has not been confirmed from a general perspective, either clinically or numerically. To characterize the influence of the implant stiffness on its functionality using the failure envelope concept that examines all possible combinations of mechanical load and application angle for selected stress, strain and displacement-based bone failure criteria. Those criteria represent bone yielding, remodeling, and implant primary stability, respectively MATERIALS AND METHODS: We performed numerical simulations to generate failure envelopes for all possible loading configurations of dental implants, with stiffness ranging from very low (polymer) to extremely high, through that of bone, titanium, and ceramics. Irrespective of the failure criterion, stiffer implants allow for improved implant functionality. The latter reduces with increasing compliance, while the trabecular bone experiences higher strains, albeit of an overall small level. Micromotions remain quite small irrespective of the implant's stiffness. The current paradigm favoring reduced implant material's stiffness out of concern for stress or strain shielding, or even excessive micromotions, is not supported by the present calculations, that point exactly to the opposite. © 2017 Wiley Periodicals, Inc.

  4. Influence of bisphosphonates on alveolar bone loss around osseointegrated implants.

    PubMed

    Zahid, Talal M; Wang, Bing-Yan; Cohen, Robert E

    2011-06-01

    The relationship between bisphosphonates (BP) and dental implant failure has not been fully elucidated. The purpose of this retrospective radiographic study was to examine whether patients who take BP are at greater risk of implant failure than patients not using those agents. Treatment records of 362 consecutively treated patients receiving endosseous dental implants were reviewed. The patient population consisted of 227 women and 135 men with a mean age of 56 years (range: 17-87 years), treated in the University at Buffalo Postgraduate Clinic from 1997-2008. Demographic information collected included age, gender, smoking status, as well as systemic conditions and medication use. Implant characteristics reviewed included system, date of placement, date of follow-up radiographs, surgical complications, number of exposed threads, and implant failure. The relationship between BP and implant failure was analyzed using generalized estimating equation (GEE) analysis. Twenty-six patients using BP received a total of 51 dental implants. Three implants failed, yielding success rates of 94.11% and 88.46% for the implant-based and subject-based analyses, respectively. Using the GEE statistical method we found a statistically significant (P  =  .001; OR  =  3.25) association between the use of BP and implant thread exposure. None of the other variables studied were statistically associated with implant failure or thread exposure. In conclusion, patients taking BP may be at higher risk for implant thread exposure.

  5. Comparison of clinical and radiographic status around dental implants placed in patients with and without prediabetes: 1-year follow-up outcomes.

    PubMed

    Al Amri, Mohammad D; Abduljabbar, Tariq S; Al-Kheraif, Abdulaziz A; Romanos, Georgios E; Javed, Fawad

    2017-02-01

    We hypothesized that peri-implant soft tissue inflammation is worse and peri-implant marginal bone loss (MBL) is higher around dental implants placed in patients with prediabetes compared to healthy subjects. The aim of the present 12-month follow-up study was to compare the clinical and radiographic status around dental implants placed in patients with and without prediabetes. Twelve patients with medically diagnosed prediabetes (Group-1) and 12 controls (Group-2) were included. All patients were indicated for single tooth maxillary or mandibular premolar replacement with the adjacent teeth intact. Success of the restored implants was assessed by comparing clinical (peri-implant bleeding on probing [BOP], and probing pocket depth [PPD]) and radiographic (peri-implant MBL) parameters at baseline and at 12-months follow-up. Statistical analysis was performed using one-way analysis of variance, and P-values <0.05 were considered statistically significant. At 12 months of follow-up, there was no clinical evidence for the presence of plaque, BOP and peri-implant pockets with PPD ≥ 4 mm in both groups. At 12-month follow-up, the mean MBL among implants placed in groups 1 and 2 were 0.2 ± 0.1 mm and 0.1 ± 0.01 mm, respectively. Overall, the periodontal status (PI, BOP and PPD ≥ 4 mm) at 12-month follow-up was comparable among patients in both groups. Within the limitations of this study, it is concluded that dental implants inserted in prediabetic and healthy patients have similar success rates and remain clinically and radiographically stable after 1-year follow-up. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Metallic ion content and damage to the DNA in oral mucosa cells patients treated dental implants.

    PubMed

    López-Jornet, Pía; Perrez, Francisco Parra; Calvo-Guirado, José Luis; Ros-Llor, Irene; LLor-Ros, Irene; Ramírez-Fernández, Piedad

    2014-07-01

    The aim of this study was to assess the potential genotoxicity of dental implants, evaluating biomarkers of DNA damage (micronuclei and/or nuclear buds), cytokinetic defects (binucleated cells) and the presence of trace metals in gingival cells of patients with implants, comparing these with a control group. A total of 60 healthy adults (30 patients with dental implants and 30 control patients without) were included in the study. Medical and dental histories were made for each including life-style factors. Genotoxicity effects were assessed by micronucleus assays in the gingival epithelial cells of each patient; 1,000 epithelial cells were analyzed, evaluating the frequency of micronucleated cells and other nuclear anomalies. The concentration of metals (Al(27), Ag(107), Co (59), Cr (52), Cu(63), Fe(56), Sn(118), Mn(55), Mo(92), Ni(60), Pb(208), Ti(47)) were assayed by means of coupled plasma-mass spectrophotometry (ICP-MS). The frequency of micronuclei in the patient group with implants was higher than in the control group but without statistically significant differences (P > 0.05). Similar results were found for binucleated cells and nuclear buds (P > 0.05). For metals assayed by ICP-MS, significant differences were found for Ti(47) (P ≤ 0.045). Univariate analysis identified a significant association between the presence of micronuclei and age. Dental implants do not induce DNA damage in gingival cells, the slight effects observed cannot be indicated as biologically relevant.

  7. Four-year follow-up of a polymethyl methacrylate-based bone cement graft for optimizing esthetics in maxillary anterior implants: a case report.

    PubMed

    Torres, Érica Miranda De; Naldi, Luis Fernando; Bernades, Karina Oliveira; Carvalho, Alexandre Leite

    2017-01-01

    Tooth loss promotes bone and gingival tissue remodeling, thus breaking the harmony between the residual ridge and natural teeth. This is critical in the anterior region of the mouth, and the integration of several dental specialties is often essential to successful rehabilitation with implants. This article describes a multidisciplinary approach to implant-supported oral rehabilitation in the maxillary anterior region, presenting a new technique for optimizing esthetics in implants. A 19-year-old woman was missing her central and lateral incisors and had 2 dental implants in the lateral incisor sites. The patient exhibited deficient thickness of the alveolar edge, loss of lip support, and absence of gingival architecture, and the implants were improperly placed. A multidisciplinary team created a correct emergence profile through a polymethyl methacrylate-based bone cement graft along with connective tissue grafts. This technique may be a useful therapeutic adjunct in dental implantology, showing good predictability and regular healing procedures.

  8. Dissolution and uptake of cadmium from dental gold solder alloy implants.

    PubMed

    Bergman, B; Bergman, M; Söremark, R

    1977-11-01

    Pure metallic cadmium was irradiated by means of thermal neutrons. The irradiated cadmium (115Cd) was placed in bags of gold foil and the bags were implanted subcutaneously in the neck region of mice. Two and 3d respectively after implantation the mice were killed, the bags removed and the animals subjected to whole-body autoradiography. The autoradiograms revealed an uptake of 115Cd in liver and kidney. In another experiment specimens of a cadmium-containing dental gold solder alloy, a cadmium-free dental casting gold alloy and soldered assemblies made of these two alloys were implanted subcutaneously in the neck region of mice. The animals were killed after 6 months; cadmium analysis showed significant increases in the cadmium concentration in liver and kidney of those mice which had been given implants of gold solder alloy. The study clearly shows that due to electrochemical corrosion cadmium can be released from implants and accumulated in the kidneys and the liver.

  9. Immediate prosthesis over implants retained using abutments with flexible screws: A preliminary study.

    PubMed

    Peñarrocha-Oltra, David; Serra-Pastor, Blanca; Balaguer-Martí, José-Carlos; Peñarrocha-Diago, Miguel; Agustín-Panadero, Rubén

    2017-12-01

    Immediate loading protocols for the rehabilitation of edentulous or partially edentulous patients have become very popular, due to the conveniences they afford in comparison with conventional loading techniques. A preliminary study was carried out with 8 patients subjected to dental implant treatment with an immediate loading protocol involving a novel system of abutments with flexible screws. Implant survival was analyzed, together with marginal bone loss and patient and dentist satisfaction. A total of 35 implants were subjected to immediate loading using the abutments with flexible screws. The mean patient and dentist satisfaction score was 9.1 and 8.5, respectively. After 12 months the dental implant survival rate was 95.8%, with a mean marginal bone loss of 0.51 ± 0.12 mm. The novel system of abutments with flexible screws offers a good alternative to conventional immediate loading, since it allows rapid and simple manufacture of a reliable passive fit, fixed interim prosthesis after surgery. Key words: Dental implants, Flexafit®, Immediate loading, Immediate prosthesis.

  10. A three-dimensional finite element analysis for overdenture attachments supported by teeth and/or mini dental implants.

    PubMed

    Fatalla, Abdalbseet A; Song, Ke; Du, Tianfeng; Cao, Yingguang

    2012-12-01

    The aim of this study was to establish the optimum design and attachment combination to support an overdenture with minimal stress and flexing produced in the alveolar bone surrounding any natural teeth and/or mini dental implants. Twelve models were included in the study: the six main models (A, B, C, D, E, and F) were categorized according to the support designs of the overdenture prosthesis, and each model was further subdivided according to the attachment combinations into model 1: with Dalbo elliptic and/or O-ring attachments only and model 2: with flexible acrylic attachments. Vertical loads (35 N) and 17.5 N lateral loads under static conditions were applied to the models to simulate the occlusal forces following the concept of lingualized occlusion. All conditions were created using a finite element software program. Maximum von Mises stress at the level of the attachments and at the bone support foundation interfaces were compared in all 12 models. The flexing of the mandible and the attachments were also compared qualitatively. Stress on these models was analyzed after the given loading condition. The results showed that the model with three freestanding mini dental implants and flexible acrylic attachments showed the lowest von Mises stress and flexing, while the models with four freestanding mini dental implants and O-ring attachments showed the highest von Mises stress. Three freestanding mini dental implants with flexible acrylic attachment systems supporting an overdenture were better choices than four mini dental implants with O-ring attachment systems, which showed the maximum flexing and stress values in this qualitative comparison. © 2012 by the American College of Prosthodontists.

  11. Antibacterial effect of copper-bearing titanium alloy (Ti-Cu) against Streptococcus mutans and Porphyromonas gingivalis

    NASA Astrophysics Data System (ADS)

    Liu, Rui; Memarzadeh, Kaveh; Chang, Bei; Zhang, Yumei; Ma, Zheng; Allaker, Robert P.; Ren, Ling; Yang, Ke

    2016-07-01

    Formation of bacterial biofilms on dental implant material surfaces (titanium) may lead to the development of peri-implant diseases influencing the long term success of dental implants. In this study, a novel Cu-bearing titanium alloy (Ti-Cu) was designed and fabricated in order to efficiently kill bacteria and discourage formation of biofilms, and then inhibit bacterial infection and prevent implant failure, in comparison with pure Ti. Results from biofilm based gene expression studies, biofilm growth observation, bacterial viability measurements and morphological examination of bacteria, revealed antimicrobial/antibiofilm activities of Ti-Cu alloy against the oral specific bacterial species, Streptococcus mutans and Porphyromonas gingivalis. Proliferation and adhesion assays with mesenchymal stem cells, and measurement of the mean daily amount of Cu ion release demonstrated Ti-Cu alloy to be biocompatible. In conclusion, Ti-Cu alloy is a promising dental implant material with antimicrobial/antibiofilm activities and acceptable biocompatibility.

  12. Analysis of the Factors Affecting Surgical Success of Implants Placed in Iranian Warfare Victims

    PubMed Central

    Jafarian, Mohammad; Bayat, Mohammad; Pakravan, Amir-Hossein; Emadi, Naghmeh

    2016-01-01

    Objective The aim was to evaluate the survival time and success rates of dental implants in warfare victims and factors that affect implant success. Subjects and Methods This retrospective study involved 250 Iranian warfare victims who received dental implants from 2003 to 2013. Patients' demographic characteristics, as well as the brand, diameter, length, location and failure rate of the implants were retrieved from patients' dental records and radiographs. The associations between these data and the survival rate were analyzed. Statistical analysis was carried out with χ2 and log-rank tests. Results Overall, out of the 1,533 dental implants, 61 (4s%) failed. The maxillary canine area had the highest failure rate [9 of 132 implants (6.8s%)], while the mandibular incisor region had the least number of failures [3 of 147 implants (2.0s%)] and the longest survival time (approximately 3,182 days). Maxillary canine areas had the shortest survival (about 2,996 days). The longest survival time was observed in implants with 11 mm length (3,179.72 ± 30.139 days) and 3.75-4 mm diameter (3,131.161 ± 35.96 days), and the shortest survival was found in implants with 11.5 mm length (2,317.79 ± 18.71 days) and 6.5 mm diameter (2,241.45 ± 182.21 days). Moreover, implants with 10 mm length (10.7s%) and 5.5-6 mm diameter (22.2s%) had the highest failure rate; however, the least failure rate occurred when the implants were 11.5 mm in length (1.9s%) and 3-3.5 mm in diameter (3.1s%). Conclusions The brand, length and diameter of implants affected the survival time, failure rate and time to failure. The location of the implant was not statistically significant regarding the mentioned factors, although it has clinical significance. PMID:27322534

  13. Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level.

    PubMed

    Šćepanović, Miodrag; Todorović, Aleksandar; Marković, Aleksa; Patrnogić, Vesna; Miličić, Biljana; Moufti, Adel M; Mišić, Tijana

    2015-05-01

    This 1-year cohort study investigated stability and peri-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Each of 30 edentulous patients received 4 mini dental implants (1.8 mm × 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic(®) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The peri-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. The primary stability (Periotest value, PTV) measured -0.27 ± 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 ± 7.05) then increased significantly reaching (PTV = 6.17 ± 6.15) at 12 months. The mean PIBL measured -0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants. Copyright © 2014 Elsevier GmbH. All rights reserved.

  14. Evaluation of bone loss in antibacterial coated dental implants: An experimental study in dogs.

    PubMed

    Godoy-Gallardo, Maria; Manzanares-Céspedes, Maria Cristina; Sevilla, Pablo; Nart, José; Manzanares, Norberto; Manero, José M; Gil, Francisco Javier; Boyd, Steven K; Rodríguez, Daniel

    2016-12-01

    The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle dogs. Sites were randomly assigned to Ti (untreated implants, 10units), Ti_Ag (silver electrodeposition treatment, 10units), and Ti_TSP (silanization treatment, 10units). Coated implants were characterized by scanning electron microscopy, interferometry and X-ray photoelectron spectroscopy. Two months after implant insertion, experimental peri-implantitis was initiated by ligature placement. Ligatures were removed 2months later, and plaque formation was allowed for 2 additional months. Clinical and radiographic analyses were performed during the study. Implant-tissue samples were prepared for micro computed tomography, backscattered scanning electron microscopy, histomorphometric and histological analyses and ion release measurements. X-ray, SEM and histology images showed that vertical bone resorption in treated implants was lower than in the control group (P<0.05). This effect is likely due to the capacity of the treatments to reduce bacteria colonization on the implant surface. Histological analysis suggested an increase of peri-implant bone formation on silanized implants. However, the short post-ligature period was not enough to detect differences in clinical parameters among implant groups. Within the limits of this study, antibacterial surface treatments have a positive effect against bone resorption induced by peri-implantitis. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. The contents of dental implant patient information leaflets available within the UK.

    PubMed

    Barber, J; Puryer, J; McNally, L; O'Sullivan, D

    2015-02-01

    Patient information leaflets are designed to provide easy to follow information summaries and first point of contact information about treatment options. This survey reviewed the content of dental implant patient information leaflets, produced by implant companies and available within the UK in 2011. Dental implant companies in the UK were asked to provide samples of their patient information leaflets. The information within the leaflets was then summarised, including the quantity and the types of images used and whether the source of the information was given. Quantitative data was obtained on the amount of information provided, size of images and number of references. A response rate of 71% was obtained and 23 leaflets were studied. Great variation was found between the leaflets, with the word counts ranging from 88 to 5,434, and 44 different topics were identified. The majority of the images used were decorative, and none of the leaflets gave any reference to the sources of their information. Implant treatment was generally described in a positive way, with an emphasis on describing the treatment and the advantages. Much less information was given about the potential disadvantages and risks of complications or failure, including the relevance of periodontal disease or smoking. Implant patient information leaflets provided by dental implant companies should not be solely relied upon to provide patients with all the information they need to give informed consent to treatment.

  16. Temperature evaluation of dental implant surface irradiated with high-power diode laser.

    PubMed

    Rios, F G; Viana, E R; Ribeiro, G M; González, J C; Abelenda, A; Peruzzo, D C

    2016-09-01

    The prevalence of peri-implantitis and the absence of a standard approach for decontamination of the dental implant surface have led to searches for effective therapies. Since the source of diode lasers is portable, has reduced cost, and does not cause damage to the titanium surface of the implant, high-power diode lasers have been used for this purpose. The effect of laser irradiation on the implants is the elevation of the temperature surface. If this elevation exceeds 47 °C, the bone tissue is irreversibly damaged, so for a safety therapy, the laser parameters should be controlled. In this study, a diode laser of GaAsAl was used to irradiate titanium dental implants, for powers 1.32 to 2.64 W (real) or 2.00 to 4.00 W (nominal), in continuous/pulsed mode DC/AC, with exposure time of 5/10 s, with/without air flow for cooling. The elevation of the temperature was monitored in real time in two positions: cervical and apical. The best results for decontamination using a 968-nm diode laser were obtained for a power of 1.65 and 1.98 W (real) for 10 s, in DC or AC mode, with an air flow of 2.5 l/min. In our perspective in this article, we determine a suggested approach for decontamination of the dental implant surface using a 968-nm diode laser.

  17. Optimally oriented grooves on dental implants improve bone quality around implants under repetitive mechanical loading.

    PubMed

    Kuroshima, Shinichiro; Nakano, Takayoshi; Ishimoto, Takuya; Sasaki, Muneteru; Inoue, Maaya; Yasutake, Munenori; Sawase, Takashi

    2017-01-15

    The aim was to investigate the effect of groove designs on bone quality under controlled-repetitive load conditions for optimizing dental implant design. Anodized Ti-6Al-4V alloy implants with -60° and +60° grooves around the neck were placed in the proximal tibial metaphysis of rabbits. The application of a repetitive mechanical load was initiated via the implants (50N, 3Hz, 1800 cycles, 2days/week) at 12weeks after surgery for 8weeks. Bone quality, defined as osteocyte density and degree of biological apatite (BAp) c-axis/collagen fibers, was then evaluated. Groove designs did not affect bone quality without mechanical loading; however, repetitive mechanical loading significantly increased bone-to-implant contact, bone mass, and bone mineral density (BMD). In +60° grooves, the BAp c-axis/collagen fibers preferentially aligned along the groove direction with mechanical loading. Moreover, osteocyte density was significantly higher both inside and in the adjacent region of the +60° grooves, but not -60° grooves. These results suggest that the +60° grooves successfully transmitted the load to the bone tissues surrounding implants through the grooves. An optimally oriented groove structure on the implant surface was shown to be a promising way for achieving bone tissue with appropriate bone quality. This is the first report to propose the optimal design of grooves on the necks of dental implants for improving bone quality parameters as well as BMD. The findings suggest that not only BMD, but also bone quality, could be a useful clinical parameter in implant dentistry. Although the paradigm of bone quality has shifted from density-based assessments to structural evaluations of bone, clarifying bone quality based on structural bone evaluations remains challenging in implant dentistry. In this study, we firstly demonstrated that the optimal design of dental implant necks improved bone quality defined as osteocytes and the preferential alignment degree of biological apatite c-axis/collagen fibers using light microscopy, polarized light microscopy, and a microbeam X-ray diffractometer system, after application of controlled mechanical load. Our new findings suggest that bone quality around dental implants could become a new clinical parameter as well as bone mineral density in order to completely account for bone strength in implant dentistry. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  18. In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture/abutment joint types using computer-aided design models.

    PubMed

    Yamaguchi, Satoshi; Yamanishi, Yasufumi; Machado, Lucas S; Matsumoto, Shuji; Tovar, Nick; Coelho, Paulo G; Thompson, Van P; Imazato, Satoshi

    2018-01-01

    The aim of this study was to evaluate fatigue resistance of dental fixtures with two different fixture-abutment connections by in vitro fatigue testing and in silico three-dimensional finite element analysis (3D FEA) using original computer-aided design (CAD) models. Dental implant fixtures with external connection (EX) or internal connection (IN) abutments were fabricated from original CAD models using grade IV titanium and step-stress accelerated life testing was performed. Fatigue cycles and loads were assessed by Weibull analysis, and fatigue cracking was observed by micro-computed tomography and a stereomicroscope with high dynamic range software. Using the same CAD models, displacement vectors of implant components were also analyzed by 3D FEA. Angles of the fractured line occurring at fixture platforms in vitro and of displacement vectors corresponding to the fractured line in silico were compared by two-way ANOVA. Fatigue testing showed significantly greater reliability for IN than EX (p<0.001). Fatigue crack initiation was primarily observed at implant fixture platforms. FEA demonstrated that crack lines of both implant systems in vitro were observed in the same direction as displacement vectors of the implant fixtures in silico. In silico displacement vectors in the implant fixture are insightful for geometric development of dental implants to reduce complex interactions leading to fatigue failure. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  19. The effect of mucosal cuff shrinkage around dental implants during healing abutment replacement.

    PubMed

    Nissan, J; Zenziper, E; Rosner, O; Kolerman, R; Chaushu, L; Chaushu, G

    2015-10-01

    Soft tissue shrinkage during the course of restoring dental implants may result in biological and prosthodontic difficulties. This study was conducted to measure the continuous shrinkage of the mucosal cuff around dental implants following the removal of the healing abutment up to 60 s. Individuals treated with implant-supported fixed partial dentures were included. Implant data--location, type, length, diameter and healing abutments' dimensions--were recorded. Mucosal cuff shrinkage, following removal of the healing abutments, was measured in bucco-lingual direction at four time points--immediately after 20, 40 and 60 s. anova was used to for statistical analysis. Eighty-seven patients (49 women and 38 men) with a total of 311 implants were evaluated (120 maxilla; 191 mandible; 291 posterior segments; 20 anterior segments). Two-hundred and five (66%) implants displayed thick and 106 (34%) thin gingival biotype. Time was the sole statistically significant parameter affecting mucosal cuff shrinkage around dental implants (P < 0.001). From time 0 to 20, 40 and 60 s, the mean diameter changed from 4.1 to 4.07, 3.4 and 2.81 mm, respectively. The shrinkage was 1%, 17% and 31%, respectively. The gingival biotype had no statistically significant influence on mucosal cuff shrinkage (P = 0.672). Time required replacing a healing abutment with a prosthetic element should be minimised (up to 20/40 s), to avoid pain, discomfort and misfit. © 2015 John Wiley & Sons Ltd.

  20. Matrix Vesicle Enzyme Activity and Phospholipid Content in Endosteal Bone Following Implantation of Osseointegrating and Non-Osseointegrating Implant Materials.

    DTIC Science & Technology

    1991-11-01

    formation of dental calculus by colonies of organized dental plaque (Boyan et al., 1982; Ennever et al., 1978b; and Sidaway, 1980). Although first thought...chamber was achieved by frontal 17 penetration of the antero-medial aspect of the exposed bone with a saline-cooled, round dental burr (#4) and a...penetration of the antero- 24 25 medial aspect of the exposed bone with a saline-cooled, round dental burr (#4) and a 20,000 RPM motor. The bone marrow

  1. Novel Osteogenic Ti-6Al-4V Device For Restoration Of Dental Function In Patients With Large Bone Deficiencies: Design, Development And Implementation

    PubMed Central

    Cohen, D. J.; Cheng, A.; Kahn, A.; Aviram, M.; Whitehead, A. J.; Hyzy, S. L.; Clohessy, R. M.; Boyan, B. D.; Schwartz, Z.

    2016-01-01

    Custom devices supporting bone regeneration and implant placement are needed for edentulous patients with large mandibular deficiencies where endosteal implantation is not possible. We developed a novel subperiosteal titanium-aluminum-vanadium bone onlay device produced by additive manufacturing (AM) and post-fabrication osteogenic micro-/nano-scale surface texture modification. Human osteoblasts produced osteogenic and angiogenic factors when grown on laser-sintered nano-/micro-textured surfaces compared to smooth surfaces. Surface-processed constructs caused higher bone-to-implant contact, vertical bone growth into disk pores (microCT and histomorphometry), and mechanical pull-out force at 5 and 10 w on rat calvaria compared to non surface-modified constructs, even when pre-treating the bone to stimulate osteogenesis. Surface-modified wrap-implants placed around rabbit tibias osseointegrated by 6 w. Finally, patient-specific constructs designed to support dental implants produced via AM and surface-processing were implanted on edentulous mandibular bone. 3 and 8 month post-operative images showed new bone formation and osseointegration of the device and indicated stability of the dental implants. PMID:26854193

  2. Novel Osteogenic Ti-6Al-4V Device For Restoration Of Dental Function In Patients With Large Bone Deficiencies: Design, Development And Implementation.

    PubMed

    Cohen, D J; Cheng, A; Kahn, A; Aviram, M; Whitehead, A J; Hyzy, S L; Clohessy, R M; Boyan, B D; Schwartz, Z

    2016-02-08

    Custom devices supporting bone regeneration and implant placement are needed for edentulous patients with large mandibular deficiencies where endosteal implantation is not possible. We developed a novel subperiosteal titanium-aluminum-vanadium bone onlay device produced by additive manufacturing (AM) and post-fabrication osteogenic micro-/nano-scale surface texture modification. Human osteoblasts produced osteogenic and angiogenic factors when grown on laser-sintered nano-/micro-textured surfaces compared to smooth surfaces. Surface-processed constructs caused higher bone-to-implant contact, vertical bone growth into disk pores (microCT and histomorphometry), and mechanical pull-out force at 5 and 10 w on rat calvaria compared to non surface-modified constructs, even when pre-treating the bone to stimulate osteogenesis. Surface-modified wrap-implants placed around rabbit tibias osseointegrated by 6 w. Finally, patient-specific constructs designed to support dental implants produced via AM and surface-processing were implanted on edentulous mandibular bone. 3 and 8 month post-operative images showed new bone formation and osseointegration of the device and indicated stability of the dental implants.

  3. The Failure Envelope Concept Applied To The Bone-Dental Implant System.

    PubMed

    Korabi, R; Shemtov-Yona, K; Dorogoy, A; Rittel, D

    2017-05-17

    Dental implants interact with the jawbone through their common interface. While the implant is an inert structure, the jawbone is a living one that reacts to mechanical stimuli. Setting aside mechanical failure considerations of the implant, the bone is the main component to be addressed. With most failure criteria being expressed in terms of stress or strain values, their fulfillment can mean structural flow or fracture. However, in addition to those effects, the bony structure is likely to react biologically to the applied loads by dissolution or remodeling, so that additional (strain-based) criteria must be taken into account. While the literature abounds in studies of particular loading configurations, e.g. angle and value of the applied load to the implant, a general study of the admissible implant loads is still missing. This paper introduces the concept of failure envelopes for the dental implant-jawbone system, thereby defining admissible combinations of vertical and lateral loads for various failure criteria of the jawbone. Those envelopes are compared in terms of conservatism, thereby providing a systematic comparison of the various failure criteria and their determination of the admissible loads.

  4. Design optimization of a radial functionally graded dental implant.

    PubMed

    Ichim, Paul I; Hu, Xiaozhi; Bazen, Jennifer J; Yi, Wei

    2016-01-01

    In this work, we use FEA to test the hypothesis that a low-modulus coating of a cylindrical zirconia dental implant would reduce the stresses in the peri-implant bone and we use design optimization and the rule of mixture to estimate the elastic modulus and the porosity of the coating that provides optimal stress shielding. We show that a low-modulus coating of a dental implant significantly reduces the maximum stresses in the peri-implant bone without affecting the average stresses thus creating a potentially favorable biomechanical environment. Our results suggest that a resilient coating is capable of reducing the maximum compressive and tensile stresses in the peri-implant bone by up to 50% and the average stresses in the peri-implant bone by up to 15%. We further show that a transitional gradient between the high-modulus core and the low-modulus coating is not necessary and for a considered zirconia/HA composite the optimal thickness of the coating is 100 µ with its optimal elastic at the lowest value considered of 45 GPa. © 2015 Wiley Periodicals, Inc.

  5. CO2 laser surface treatment of failed dental implants for re-implantation: an animal study.

    PubMed

    Kasraei, Shahin; Torkzaban, Parviz; Shams, Bahar; Hosseinipanah, Seyed Mohammad; Farhadian, Maryam

    2016-07-01

    The aim of the present study was to evaluate the success rate of failed implants re-implanted after surface treatment with CO2 laser. Despite the widespread use of dental implants, there are many incidents of failures. It is believed that lasers can be applied to decontaminate the implant surface without damaging the implant. Ten dental implants that had failed for various reasons other than fracture or surface abrasion were subjected to CO2 laser surface treatment and randomly placed in the maxillae of dogs. Three failed implants were also placed as the negative controls after irrigation with saline solution without laser surface treatment. The stability of the implants was evaluated by the use of the Periotest values (PTVs) on the first day after surgery and at 1, 3, and 6 months post-operatively. The mean PTVs of treated implants increased at the first month interval, indicating a decrease in implant stability due to inflammation followed by healing of the tissue. At 3 and 6 months, the mean PTVs decreased compared to the 1-month interval (P < 0.05), indicating improved implant stability. The mean PTVs increased in the negative control group compared to baseline (P < 0.05). Independent t-test showed that the mean PTVs of treated implants were significantly lower than control group at 3 and 6 months after implant placement (P < 0.05). Based on the PTVs, re-implantation of failed implants in Jack Russell Terrier dogs after CO2 laser surface debridement is associated with a high success rate in terms of implant stability.

  6. Prevalence of neuropathic pain and sensory alterations after dental implant placement in a university-based oral surgery department: A retrospective cohort study.

    PubMed

    Vázquez-Delgado, Eduardo; Viaplana-Gutiérrez, Marta; Figueiredo, Rui; Renton, Tara; Gay-Escoda, Cosme; Valmaseda-Castellón, Eduard

    2018-06-01

    To determine the prevalence and the clinical features of patients with neuropathic pain and sensory alterations after dental implant placement. Literature is very scarce concerning the prevalence of neuropathic pain after dental implant placement. A retrospective cohort study was made in patients submitted to dental implant placement in the Dental Hospital of the University of Barcelona. A descriptive analysis of the data was made, and the 95% confidence intervals (95% CI) were calculated for the prevalences. The study sample was composed of 1156 subjects of whom, 1012 patients (3743 dental implants) met the study inclusion criteria. Four hundred and seventeen patients (41.2%) were male and 595 (58.8%) were female, with a mean age of 60.7 years (range 16-90 years). Three patients were diagnosed as having painful post-traumatic trigeminal neuropathy (PPTN), which corresponds to a prevalence of 0.3% (95% CI: 0%-0.6%). Additionally, 5 patients (0.5%; 95% CI: 0%-1.07%) presented trigeminal neuropathy without pain (TNWP). The combined prevalence of both disorders was 0.8% (95% CI: 0.02%-1.3%). All patients with PPTN and TNWP were 60 years old or older, with a total combined prevalence of 1.48% (95% CI: 0.46%-2.5%) in this age group. Additionally, the prevalence in this age group for women was 1.85% (95%CI: 0.38%-3.31%). Neuropathic pain after dental implant placement is very infrequent (0.3%) in a University Oral Surgery department. However, the presence of trigeminal neuropathies can be slightly higher and can affect up to 0.5% of patients. Older female patients seem to be more prone to this rare and disabling complication. © 2018 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  7. Purposeful exposure of a polylactic acid barrier to achieve socket preservation for placement of dental implants: case series report.

    PubMed

    Rosen, Paul S; Rosen, Adam D

    2013-01-01

    This retrospective case series reports on the use of a polylactic acid barrier that was left exposed in the process of socket preparation for the placement of dental implants. A retrospective chart review found 43 patients with 48 extraction sockets that were treated in this manner. Teeth were removed and the sockets were thoroughly debrided, with 40 of them receiving a bone replacement graft covered by the polylactic acid barrier and the additional 8 receiving the membrane alone. Suturing left the barrier exposed, and the sites were re-entered on average at 23 weeks for the placement of a dental implant. All sites were able to receive a dental implant, demonstrating the ability to leave a polylactic acid barrier exposed and achieve successful guided bone regeneration (GBR) results. This ultimately helped avoid some of the negative sequelae of trying to achieve primary closure of the flaps at the time of tooth extraction.

  8. Osteoblastic differentiating potential of dental pulp stem cells in vitro cultured on a chemically modified microrough titanium surface.

    PubMed

    DE Colli, Marianna; Radunovic, Milena; Zizzari, Vincenzo L; DI Giacomo, Viviana; DI Nisio, Chiara; Piattelli, Adriano; Calvo Guirado, José L; Zavan, Barbara; Cataldi, Amelia; Zara, Susi

    2018-03-30

    Titanium surface modification is critical for dental implant success. Our aim was to determine surfaces influence on dental pulp stem cells (DPSCs) viability and differentiation. Implants were divided into sandblasted/acid-etched (control) and sandblasted/acid-etched coated with calcium and magnesium ions (CaMg), supplied as composite (test). Proliferation was evaluated by MTT, differentiation checking osteoblastic gene expression, PGE2 secretion and matrix formation, inflammation by Interleukin 6 (IL-6) detection. MTT and IL-6 do not modify on test. A PGE2 increase on test is recorded. BMP2 is higher on test at early experimental points, Osterix and RUNX2 augment later. Alizarin-red S reveals higher matrix production on test. These results suggest that test surface is more osteoinductive, representing a start point for in vivo studies aiming at the construction of more biocompatible dental implants, whose integration and clinical performance are improved and some undesired effects, such as implant stability loss and further surgical procedures, are reduced.

  9. The efficacy of antibiotic prophylaxis at placement of dental implants: a Cochrane systematic review of randomised controlled clinical trials.

    PubMed

    Esposito, Marco; Grusovin, Maria Gabriella; Coulthard, Paul; Oliver, Richard; Worthington, Helen V

    To assess the beneficial or harmful effects of systemic prophylactic antibiotics at dental implant placement versus no antibiotic/placebo administration and, if antibiotics are of benefit, to find which type, dosage and duration is the most effective. The Cochrane Oral Health Group's Trials Register, CENTRAL, MEDLINE and EMBASE were searched and several journals were handsearched with no language restriction up to January 2008. Randomised controlled trials (RCTs) with a follow up of at least 3 months comparing the administration of various prophylactic antibiotic regimens versus no antibiotics to patients undergoing dental implant placement were eligible. Screening of studies, quality assessment and data extraction were conducted in duplicate. Missing information was requested. Outcome measures were: prosthesis and implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc.). Two RCTs were identified: one comparing 2 g of preoperative amoxicillin versus placebo (316 patients) and the other comparing 2 g of preoperative amoxicillin + 500 mg four times a day for 2 days versus no antibiotics (80 patients). The meta-analyses of the two trials showed a statistically significant higher number of patients experiencing implant failures in the group not receiving antibiotics: RR = 0.22 (95% CI 0.06 to 0.86). The number needed to treat (NNT) to prevent one patient having an implant failure is 25 (95% CI 13 to 100), based on a patient implant failure rate of 6% in patients not receiving antibiotics. The other outcomes were not statistically significant, and only two minor adverse events were recorded, one of which was in the placebo group. There is some evidence suggesting that 2 g of amoxicillin given 1 hour preoperatively significantly reduce failures of dental implants placed in ordinary conditions. It remains unclear whether postoperative antibiotics are beneficial, and which is the most effective antibiotic. It might be recommendable to suggest the use of one dose of prophylactic antibiotics prior to dental implant placement.

  10. Modulation of human dermal microvascular endothelial cell and human gingival fibroblast behavior by micropatterned silica coating surfaces for zirconia dental implant applications

    PubMed Central

    Laranjeira, Marta S; Carvalho, Ângela; Pelaez-Vargas, Alejandro; Hansford, Derek; Ferraz, Maria Pia; Coimbra, Susana; Costa, Elísio; Santos-Silva, Alice; Fernandes, Maria Helena; Monteiro, Fernando Jorge

    2014-01-01

    Dental ceramic implants have shown superior esthetic behavior and the absence of induced allergic disorders when compared to titanium implants. Zirconia may become a potential candidate to be used as an alternative to titanium dental implants if surface modifications are introduced. In this work, bioactive micropatterned silica coatings were produced on zirconia substrates, using a combined methodology of sol–gel processing and soft lithography. The aim of the work was to compare the in vitro behavior of human gingival fibroblasts (HGFs) and human dermal microvascular endothelial cells (HDMECs) on three types of silica-coated zirconia surfaces: flat and micropatterned (with pillars and with parallel grooves). Our results showed that cells had a higher metabolic activity (HGF, HDMEC) and increased gene expression levels of fibroblast-specific protein-1 (FSP-1) and collagen type I (COL I) on surfaces with pillars. Nevertheless, parallel grooved surfaces were able to guide cell growth. Even capillary tube-like networks of HDMEC were oriented according to the surface geometry. Zirconia and silica with different topographies have shown to be blood compatible and silica coating reduced bacteria adhesion. All together, the results indicated that microstructured bioactive coating seems to be an efficient strategy to improve soft tissue integration on zirconia implants, protecting implants from peri-implant inflammation and improving long-term implant stabilization. This new approach of micropatterned silica coating on zirconia substrates can generate promising novel dental implants, with surfaces that provide physical cues to guide cells and enhance their behavior. PMID:27877662

  11. Modulation of human dermal microvascular endothelial cell and human gingival fibroblast behavior by micropatterned silica coating surfaces for zirconia dental implant applications

    NASA Astrophysics Data System (ADS)

    Laranjeira, Marta S.; Carvalho, Ângela; Pelaez-Vargas, Alejandro; Hansford, Derek; Ferraz, Maria Pia; Coimbra, Susana; Costa, Elísio; Santos-Silva, Alice; Fernandes, Maria Helena; Monteiro, Fernando Jorge

    2014-04-01

    Dental ceramic implants have shown superior esthetic behavior and the absence of induced allergic disorders when compared to titanium implants. Zirconia may become a potential candidate to be used as an alternative to titanium dental implants if surface modifications are introduced. In this work, bioactive micropatterned silica coatings were produced on zirconia substrates, using a combined methodology of sol-gel processing and soft lithography. The aim of the work was to compare the in vitro behavior of human gingival fibroblasts (HGFs) and human dermal microvascular endothelial cells (HDMECs) on three types of silica-coated zirconia surfaces: flat and micropatterned (with pillars and with parallel grooves). Our results showed that cells had a higher metabolic activity (HGF, HDMEC) and increased gene expression levels of fibroblast-specific protein-1 (FSP-1) and collagen type I (COL I) on surfaces with pillars. Nevertheless, parallel grooved surfaces were able to guide cell growth. Even capillary tube-like networks of HDMEC were oriented according to the surface geometry. Zirconia and silica with different topographies have shown to be blood compatible and silica coating reduced bacteria adhesion. All together, the results indicated that microstructured bioactive coating seems to be an efficient strategy to improve soft tissue integration on zirconia implants, protecting implants from peri-implant inflammation and improving long-term implant stabilization. This new approach of micropatterned silica coating on zirconia substrates can generate promising novel dental implants, with surfaces that provide physical cues to guide cells and enhance their behavior.

  12. A Survey of the Opinion and Experience of UK Dentists: Part 1: The Incidence and Cause of Iatrogenic Trigeminal Nerve Injuries Related to Dental Implant Surgery.

    PubMed

    Yilmaz, Zehra; Ucer, Cemal; Scher, Edwin; Suzuki, Jon; Renton, Tara

    2016-10-01

    Dental implant-related iatrogenic trigeminal nerve (TG) injuries are proportionally increasing with dental implant surgery. This study, which is presented in greater detail over a series of articles, assessed the experience of implant-related TG nerve injuries among UK dentists. Incidence and cause of inferior alveolar nerve (IAN), mental nerve (MN), and lingual nerve (LN) injuries, together with preoperative assessment and the consent process, are presented in this article. A survey was distributed among 405 dentists attending an Association of Dental Implantology congress in the United Kingdom, of which 187 completed the survey. Most responding dentists were full-time general practitioners. Implant dentistry training was predominately through industry-organized courses. Eighty dentists encountered implant-related IAN injuries, whereas 8 encountered LN injuries. Inaccurate radiological identification of the IAN/MN and their anatomical variations (48%) were seen to be the most frequent cause of TG injuries. Disclosure of the relative risk and benefits of alternative implant treatment strategies as part of the informed consent process was not deemed to be essential by 47 (25%) of the participants. Inadequate radiological assessment was the most common cause of TG nerve injury. The use of small field of view cone beam computer tomography (CBCT) is therefore recommended when placing implants in the posterior mandible. Implant surgeons should acquire evidence-based skills in the prevention, diagnosis, and management of TG nerve injury as well as specific training on justification and interpretation of CBCT scans.

  13. Does Bruxism Contribute to Dental Implant Failure? A Systematic Review and Meta-Analysis.

    PubMed

    Zhou, Yi; Gao, Jinxia; Luo, Le; Wang, Yining

    2016-04-01

    Bruxism was usually considered as a contraindication for oral implanting. The causal relationship between bruxism and dental implant failure was remained controversial in existing literatures. This meta-analysis was performed to investigate the relationship between them. This review conducted an electronic systematic literature search in MEDLINE (PubMed) and EmBase in November 2013 without time and language restrictions. Meanwhile, a hand searching for all the relevant references of included studies was also conducted. Study information extraction and methodological quality assessments were accomplished by two reviewers independently. A discussion ensued if any disagreement occurred, and unresolved issues were solved by consulting a third reviewer. Methodological quality was assessed by using the Newcastle-Ottawa Scale tool. Odds ratio (OR) with 95% confidence interval (CI) was pooled to estimate the relative effect of bruxism on dental implant failures. Fixed effects model was used initially; if the heterogeneity was high, random effects model was chosen for meta-analysis. Statistical analyses were carried out by using Review Manager 5.1. In this meta-analysis review, extracted data were classified into two groups based on different units. Units were based on the number of prostheses (group A) and the number of patients (group B). In group A, the total pooled OR of bruxers versus nonbruxers for all subgroups was 4.72 (95% CI: 2.66-8.36, p = .07). In group B, the total pooled OR of bruxers versus nonbruxers for all subgroups was 3.83 (95% CI: 2.12-6.94, p = .22). This meta-analysis was performed to evaluate the relationship between bruxism and dental implant failure. In contrast to nonbruxers, prostheses in bruxers had a higher failure rate. It suggests that bruxism is a contributing factor of causing the occurrence of dental implant technical/biological complications and plays a role in dental implant failure. © 2015 Wiley Periodicals, Inc.

  14. Analysis of the influence of the macro- and microstructure of dental zirconium implants on osseointegration: a minipig study.

    PubMed

    Mueller, Cornelia Katharina; Solcher, Philipp; Peisker, Andrè; Mtsariashvilli, Maia; Schlegel, Karl Andreas; Hildebrand, Gerhard; Rost, Juergen; Liefeith, Klaus; Chen, Jiang; Schultze-Mosgau, Stefan

    2013-07-01

    It was the aim of this study to analyze the influence of implant design and surface topography on the osseointegration of dental zirconium implants. Six different implant designs were tested in the study. Nine or 10 test implants were inserted in the frontal skull in each of 10 miniature pigs. Biopsies were harvested after 2 and 4 months and subjected to microradiography. No significant differences between titanium and zirconium were found regarding the microradiographically detected bone-implant contact (BIC). Cylindric zirconium implants showed a higher BIC at the 2-month follow-up than conic zirconium implants. Among zirconium implants, those with an intermediate Ra value showed a significantly higher BIC compared with low and high Ra implants 4 months after surgery. Regarding osseointegration, titanium and zirconium showed equal properties. Cylindric implant design and intermediate surface roughness seemed to enhance osseointegration. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Dental rehabilitation using an implant-carrying plate system in a severely resorbed edentulous maxilla: a case report.

    PubMed

    Kurita, Hiroshi; Sakai, Hironori; Uehara, Shinobu; Kurashina, Kenji

    2008-01-01

    This clinical article describes a case of dental rehabilitation using an implant-carrying plate system (EPITEC) for a patient with severely resorbed edentulous maxilla and microstomia. In this case, the presence of microstomia prevented bone augmentation procedures through an intraoral approach. Treatment using 2 endosseous implants inserted in the canine regions and an implant-supported overdenture was planned. However, endosseous implants were not feasible on the right side because of insufficient available bone volume. An implant-carrying plate system was then utilized on the right side. Four months later, an implant-supported ball-attachment overdenture was fabricated. At the 2-year follow-up, the clinical course remained uneventful, and the patient remained satisfied with the treatment.

  16. Custom Titanium Ridge Augmentation Matrix (CTRAM): A Case Report.

    PubMed

    Connors, Christopher A; Liacouras, Peter C; Grant, Gerald T

    2016-01-01

    This is a case report of a custom titanium ridge augmentation matrix (CTRAM). Using cone beam computed tomography (CBCT), a custom titanium space-maintaining device was developed. Alveolar ridges were virtually augmented, a matrix was virtually designed, and the CTRAM was additively manufactured with titanium (Ti6Al4V). Two cases are presented that resulted in sufficient increased horizontal bone volume with successful dental implant placement. The CTRAM design allows for preoperative planning for increasing alveolar ridge dimensions to support dental implants, reduces surgical time, and prevents the need for a second surgical site to gain sufficient alveolar ridge bone volume for dental implant therapy.

  17. Technical complications of implant-causes and management: A comprehensive review

    PubMed Central

    Gupta, Swati; Gupta, Hemant; Tandan, Amrit

    2015-01-01

    Given the increasing popularity of dental implants, the number of failures due to late implant fracture is also expected to increase. Hence, the scope for prevention and management needs to be emphasized. The objective of this review article is to analyze the various causes of failure of dental implants due to implant fixture/abutment screw fractures and also to enumerate the management and the preventive options for these failures, thereby aiming to help the clinicians to properly plan the implant-supported prosthesis treatment by considering the important biomechanical aspects of this type of rehabilitation. The present review emphasizes the causes and management of technical complications and not the incidence of such complications. PMID:26668445

  18. Management of Patients with Orthopaedic Implants Undergoing Dental Procedures.

    PubMed

    Quinn, Robert H; Murray, Jayson N; Pezold, Ryan; Sevarino, Kaitlyn S

    2017-07-01

    The American Academy of Orthopaedic Surgeons, in collaboration with the American Dental Association, has developed Appropriate Use Criteria (AUC) for the Management of Patients with Orthopaedic Implants Undergoing Dental Procedures. Evidence-based information, in conjunction with the clinical expertise of physicians, was used to develop the criteria to improve patient care and obtain best outcomes while considering the subtleties and distinctions necessary in making clinical decisions. The Management of Patients with Orthopaedic Implants Undergoing Dental Procedures AUC clinical patient scenarios were derived from indications of patients with orthopaedic implants presenting for dental procedures, as well as from current evidence-based clinical practice guidelines and supporting literature to identify the appropriateness of the use of prophylactic antibiotics. The 64 patient scenarios and 1 treatment were developed by the writing panel, a group of clinicians who are specialists in this AUC topic. Next, a separate, multidisciplinary, voting panel (made up of specialists and nonspecialists) rated the appropriateness of treatment of each patient scenario using a 9-point scale to designate a treatment as Appropriate (median rating, 7 to 9), May Be Appropriate (median rating, 4 to 6), or Rarely Appropriate (median rating, 1 to 3).

  19. Processing and Development of Nano-Scale HA Coatings for Biomedical Application

    DTIC Science & Technology

    2005-01-01

    thickness of the film has been processed and tested as a more effective orthopedic/ dental implant coating. The present study aims to increase the service...life of an orthopedic/ dental implant by creating materials that form a strong, long lasting, bond with the Ti substrate as well as juxtaposed bone... dental replacement surgery may quickly return to a normal active lifestyle. Cross-sectional transmission electron microscopy analysis displayed that the

  20. In vivo osseointegration of dental implants with an antimicrobial peptide coating.

    PubMed

    Chen, X; Zhou, X C; Liu, S; Wu, R F; Aparicio, C; Wu, J Y

    2017-05-01

    This study aimed to evaluate the in vivo osseointegration of implants with hydrophobic antimicrobial GL13K-peptide coating in rabbit femoral condyles by micro-CT and histological analysis. Six male Japanese Rabbits (4 months old and weighing 2.5 kg each) were included in this study. Twelve implants (3.75 mm wide, 7 mm long) were randomly distributed in two groups, with six implants in the experimental group coated with GL13K peptide and six implants in the control group without surface coating. Each implant in the test and the control group was randomly implanted in the left or right side of femoral condyles. On one side randomly-selected of the femur, each rabbit received a drill that was left without implant as control for the natural healing of bone. After 3 weeks of healing radiographic evaluation of the implant sites was taken. After 6 weeks of healing, rabbits were sacrificed for evaluation of the short-term osseointegration of the dental implants using digital radiography, micro-CT and histology analysis. To perform evaluation of osseointegration, implant location and group was double blinded for surgeon and histology/radiology researcher. Two rabbits died of wound infection in sites with non-coated implants 2 weeks after surgery. Thus, at least four rabbits per group survived after 6 weeks of healing. The wounds healed without suppuration and inflammation. No implant was loose after 6 weeks of healing. Radiography observations showed good osseointegration after 3 and 6 weeks postoperatively, which proved that the tissues followed a natural healing process. Micro-CT reconstruction and analysis showed that there was no statistically significant difference (P > 0.05) in volume of bone around the implant between implants coated with GL13K peptide and implants without coating. Histomorphometric analysis also showed that the mineralized bone area was no statistically different (P > 0.05) between implants coated with GL13K peptide and implants without coating. This study demonstrates that titanium dental implants with an antimicrobial GL13K coating enables in vivo implant osseointegration at similar bone growth rates than gold-standard non-coated dental implants up to 6 weeks of implantation in rabbit femurs.

  1. Implant bone integration importance in forensic identification.

    PubMed

    De Angelis, Danilo; Cattaneo, Cristina

    2015-03-01

    Odontological identification consists of the comparison of antemortem dental information regarding a missing person with postmortem data from an unidentified corpse or human remains. Usually, the comparison concerns morphologic features that the operator chooses among all the visible characteristics because of inter-individual uniqueness; for this reason, implants can be of enormous assistance. A case concerning the recovery of a burnt oral implant, connected to a bone fragment, among 2780 charred bone fragments, suspected to have belonged to a victim of homicide, is presented to demonstrate that dental implants and their site of bone integration represent a very precious element for personal forensic identification. Because of their morphological invariability in time and because of their morphologic uniqueness, they were used as evidence to associate unidentified human charred remains to a missing person where DNA analysis failed to do so. The case illustrates the fundamental contribution, not yet described in literature, given by the clinical aspects of tooth replacement with dental implants to a forensic discipline. Clinical practitioners should therefore be aware of the great importance of their work and of dental records in a forensic identification scenario. © 2014 American Academy of Forensic Sciences.

  2. Advanced Implant-Prosthetic Rehabilitation: How to Obtain a Correct Restoration of Both Functions and Aesthetics in Patients with Complex Combined Dental and Maxillofacial Trauma: A Case Report and Topical Review of the Literature.

    PubMed

    Figliuzzi, M M; Giudice, A; Fortunato, L

    2017-01-01

    Aim . This study aims to explain the main steps that characterize the implant-prosthetic rehabilitation in complex combined dental and maxillofacial trauma. Material and Methods . A 20-year-old patient reported an extensive facial trauma which also involved the alveolar process of the maxillary bone. The patient reported a maxillofacial fracture and the loss of teeth 1.3, 1.2, 1.1, and 2.1. A "Le Fort" type 2 fracture was also reported, with the malar bone involvement. After reduction and containment of bone fractures, through appropriate mounting plates, appropriate functional and aesthetic rehabilitation of the patient were replaced thanks to a temporary removable prosthesis. After 6 months, the patient performed numerous clinical investigations, aimed at a proper planning of implant-prosthetic rehabilitation of the upper dental arch. Conclusion . With the planning of the case, as well as respecting the surrounding biological structures, the surgery of implants can be carried out with the most appropriate procedure. Lastly, new dental implants with highly bioactive surfaces have been developed, providing an excellent and rapid bone integration.

  3. Allergic contact dermatitis caused by titanium screws and dental implants.

    PubMed

    Hosoki, Maki; Nishigawa, Keisuke; Miyamoto, Youji; Ohe, Go; Matsuka, Yoshizo

    2016-07-01

    Titanium has been considered to be a non-allergenic material. However, several studies have reported cases of metal allergy caused by titanium-containing materials. We describe a 69-year-old male for whom significant pathologic findings around dental implants had never been observed. He exhibited allergic symptoms (eczema) after orthopedic surgery. The titanium screws used in the orthopedic surgery that he underwent were removed 1 year later, but the eczema remained. After removal of dental implants, the eczema disappeared completely. Titanium is used not only for medical applications such as plastic surgery and/or dental implants, but also for paints, white pigments, photocatalysts, and various types of everyday goods. Most of the usage of titanium is in the form of titanium dioxide. This rapid expansion of titanium-containing products has increased percutaneous and permucosal exposure of titanium to the population. In general, allergic risk of titanium material is smaller than that of other metal materials. However, we suggest that pre-implant patients should be asked about a history of hypersensitivity reactions to metals, and patch testing should be recommended to patients who have experienced such reactions. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Numb chin syndrome as a manifestation of possible breast cancer metastasis around dental implants.

    PubMed

    Orhan, Kaan; Bayndr, Hakan; Aksoy, Seçil; Seker, Basak Kusakci; Berberoğlu, Atilla; Ozan, Oğuz

    2011-05-01

    Numb chin syndrome, sometimes called numb lip syndrome, is an uncommon but well-recognized symptom in medical oncology. It may be a metastatic neurologic manifestation of malignancy, often with no clinically visible pathologic finding. The authors report a numb chin syndrome as a manifestation possible breast cancer metastasis around dental implants in a 69-year-old woman. The patient was presented with complaint of numbness in the lower jaw. Medical anamnesis revealed a metastatic breast carcinoma (CA). Radiographic imaging with conventional panoramic radiography and cone beam computed tomographic examination, revealed a moth-eaten shape, radiolucent, and radiopaque mixed appearance around the dental implants that was related with possible metastasis of the breast cancer. Numb chin syndrome is almost unknown within the dental and oral and maxillofacial community, despite being well reported in the medical literature. General dentists, oral medicine specialists, and oral and maxillofacial surgeons must be aware of this condition to consider metastatic cancer in patients with unexplained facial hypoesthesia. Moreover, although the development of metastatic lesions around implants is an uncommon pathologic finding, the examination of peri-implant lesion should be performed carefully considering the entire pathologic situations.

  5. Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis.

    PubMed

    Frisardi, Gianni; Barone, Sandro; Razionale, Armando V; Paoli, Alessandro; Frisardi, Flavio; Tullio, Antonio; Lumbau, Aurea; Chessa, Giacomo

    2012-05-29

    A fundamental pre-requisite for the clinical success in dental implant surgery is the fast and stable implant osseointegration. The press-fit phenomenon occurring at implant insertion induces biomechanical effects in the bone tissues, which ensure implant primary stability. In the field of dental surgery, the understanding of the key factors governing the osseointegration process still remains of utmost importance. A thorough analysis of the biomechanics of dental implantology requires a detailed knowledge of bone mechanical properties as well as an accurate definition of the jaw bone geometry. In this work, a CT image-based approach, combined with the Finite Element Method (FEM), has been used to investigate the effect of the drill size on the biomechanics of the dental implant technique. A very accurate model of the human mandible bone segment has been created by processing high resolution micro-CT image data. The press-fit phenomenon has been simulated by FE analyses for different common drill diameters (DA=2.8 mm, DB=3.3 mm, and DC=3.8 mm) with depth L=12 mm. A virtual implant model has been assumed with a cylindrical geometry having height L=11 mm and diameter D=4 mm. The maximum stresses calculated for drill diameters DA, DB and DC have been 12.31 GPa, 7.74 GPa and 4.52 GPa, respectively. High strain values have been measured in the cortical area for the models of diameters DA and DB, while a uniform distribution has been observed for the model of diameter DC . The maximum logarithmic strains, calculated in nonlinear analyses, have been ϵ=2.46, 0.51 and 0.49 for the three models, respectively. This study introduces a very powerful, accurate and non-destructive methodology for investigating the effect of the drill size on the biomechanics of the dental implant technique.Further studies could aim at understanding how different drill shapes can determine the optimal press-fit condition with an equally distributed preload on both the cortical and trabecular structure around the implant.

  6. Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis

    PubMed Central

    2012-01-01

    Background A fundamental pre-requisite for the clinical success in dental implant surgery is the fast and stable implant osseointegration. The press-fit phenomenon occurring at implant insertion induces biomechanical effects in the bone tissues, which ensure implant primary stability. In the field of dental surgery, the understanding of the key factors governing the osseointegration process still remains of utmost importance. A thorough analysis of the biomechanics of dental implantology requires a detailed knowledge of bone mechanical properties as well as an accurate definition of the jaw bone geometry. Methods In this work, a CT image-based approach, combined with the Finite Element Method (FEM), has been used to investigate the effect of the drill size on the biomechanics of the dental implant technique. A very accurate model of the human mandible bone segment has been created by processing high resolution micro-CT image data. The press-fit phenomenon has been simulated by FE analyses for different common drill diameters (DA = 2.8 mm, DB = 3.3 mm, and DC = 3.8 mm) with depth L = 12 mm. A virtual implant model has been assumed with a cylindrical geometry having height L = 11 mm and diameter D = 4 mm. Results The maximum stresses calculated for drill diameters DA, DB and DC have been 12.31 GPa, 7.74 GPa and 4.52 GPa, respectively. High strain values have been measured in the cortical area for the models of diameters DA and DB, while a uniform distribution has been observed for the model of diameter DC . The maximum logarithmic strains, calculated in nonlinear analyses, have been ϵ = 2.46, 0.51 and 0.49 for the three models, respectively. Conclusions This study introduces a very powerful, accurate and non-destructive methodology for investigating the effect of the drill size on the biomechanics of the dental implant technique. Further studies could aim at understanding how different drill shapes can determine the optimal press-fit condition with an equally distributed preload on both the cortical and trabecular structure around the implant. PMID:22642768

  7. Fatigue induced changes in conical implant-abutment connections.

    PubMed

    Blum, Kai; Wiest, Wolfram; Fella, Christian; Balles, Andreas; Dittmann, Jonas; Rack, Alexander; Maier, Dominik; Thomann, Ralf; Spies, Benedikt Christopher; Kohal, Ralf Joachim; Zabler, Simon; Nelson, Katja

    2015-11-01

    Based on the current lack of data and understanding of the wear behavior of dental two-piece implants, this study aims for evaluating the microgap formation and wear pattern of different implants in the course of cyclic loading. Several implant systems with different conical implant-abutment interfaces were purchased. The implants were first evaluated using synchrotron X-ray high-resolution radiography (SRX) and scanning electron microscopy (SEM). The implant-abutment assemblies were then subjected to cyclic loading at 98N and their microgap was evaluated after 100,000, 200,000 and 1 million cycles using SRX, synchrotron micro-tomography (μCT). Wear mechanisms of the implant-abutment connection (IAC) after 200,000 cycles and 1 million cycles were further characterized using SEM. All implants exhibit a microgap between the implant and abutment prior to loading. The gap size increased with cyclic loading with its changes being significantly higher within the first 200,000 cycles. Wear was seen in all implants regardless of their interface design. The wear pattern comprised adhesive wear and fretting. Wear behavior changed when a different mounting medium was used (brass vs. polymer). A micromotion of the abutment during cyclic loading can induce wear and wear particles in conical dental implant systems. This feature accompanied with the formation of a microgap at the IAC is highly relevant for the longevity of the implants. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. The influence of body mass index, age, implants, and dental restorations on image quality of cone beam computed tomography.

    PubMed

    Ritter, Lutz; Mischkowski, Robert A; Neugebauer, Jörg; Dreiseidler, Timo; Scheer, Martin; Keeve, Erwin; Zöller, Joachim E

    2009-09-01

    The aim was to determine the influence of patient age, gender, body mass index (BMI), amount of dental restorations, and implants on image quality of cone-beam computerized tomography (CBCT). Fifty CBCT scans of a preretail version of Galileos (Sirona, Germany) were investigated retrospectively by 4 observers regarding image quality of 6 anatomic structures, pathologic findings detection, subjective exposure quality, and artifacts. Patient age, BMI, gender, amount of dental restorations, and implants were recorded and statistically tested for correlations to image quality. A negative effect on image quality was found statistically significantly correlated with age and the amount of dental restorations. None of the investigated image features were garbled by any of the investigated influence factors. Age and the amount of dental restorations appear to have a negative impact on CBCT image quality, whereas gender and BMI do not. Image quality of mental foramen, mandibular canal, and nasal floor are affected negatively by age but not by the amount of dental restorations. Further studies are required to elucidate influence factors on CBCT image quality.

  9. Osseointegration properties of titanium dental implants modified with a nanostructured coating based on ordered porous silica and bioactive glass nanoparticles

    NASA Astrophysics Data System (ADS)

    Covarrubias, Cristian; Mattmann, Matías; Von Marttens, Alfredo; Caviedes, Pablo; Arriagada, Cristián; Valenzuela, Francisco; Rodríguez, Juan Pablo; Corral, Camila

    2016-02-01

    The fabrication of a nanoporous silica coating loaded with bioactive glass nanoparticles (nBG/NSC) on titanium dental implant surface and its in vitro and in vivo evaluation is presented. The coating was produced by a combined sol-gel and evaporation induced self-assembly process. In vitro bioactivity was assessed in simulated body fluid (SBF) and investigating the osteogenic differentiation of human bone marrow mesenchymal stem cells (hBMSCs). A rat tibial model was employed to analyze the bone response to nBG/NSC-modified titanium implant surface in vivo. The nBG/NSC coating was confirmed at nano level to be constituted by a highly ordered nanoporous silica structure. The coating nanotopography in conjunction with the bioactivity of the BG particles accelerate the in vitro apatite formation and promote the osteogenic differentiation of hBMSCs in absence of osteogenic supplements. These properties accelerate the formation of bone tissue in the periphery of the implant after 3 weeks of implantation. Backscattered scanning electron microscopy images revealed the presence of gaps and soft tissue in the unmodified implant after 6 weeks, whereas the nBG/NSC-modified implant showed mature bone in intimate contact with the implant surface. The nBG/NSC coating appears promising for accelerating the osseointegration of dental implants.

  10. Implant Surface Design Regulates Mesenchymal Stem Cell Differentiation and Maturation

    PubMed Central

    Boyan, B.D.; Cheng, A.; Olivares-Navarrete, R.; Schwartz, Z.

    2016-01-01

    Changes in dental implant materials, structural design, and surface properties can all affect biological response. While bulk properties are important for mechanical stability of the implant, surface design ultimately contributes to osseointegration. This article reviews the surface parameters of dental implant materials that contribute to improved cell response and osseointegration. In particular, we focus on how surface design affects mesenchymal cell response and differentiation into the osteoblast lineage. Surface roughness has been largely studied at the microscale, but recent studies have highlighted the importance of hierarchical micron/submicron/nanosurface roughness, as well as surface roughness in combination with surface wettability. Integrins are transmembrane receptors that recognize changes in the surface and mediate downstream signaling pathways. Specifically, the noncanonical Wnt5a pathway has been implicated in osteoblastic differentiation of cells on titanium implant surfaces. However, much remains to be elucidated. Only recently have studies been conducted on the differences in biological response to implants based on sex, age, and clinical factors; these all point toward differences that advocate for patient-specific implant design. Finally, challenges in implant surface characterization must be addressed to optimize and compare data across studies. An understanding of both the science and the biology of the materials is crucial for developing novel dental implant materials and surface modifications for improved osseointegration. PMID:26927483

  11. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review

    PubMed Central

    Shadid, Rola Muhammed; Sadaqah, Nasrin Rushdi; Othman, Sahar Abdo

    2014-01-01

    Background. A number of surgical techniques for implant site preparation have been advocated to enhance the implant of primary and secondary stability. However, there is insufficient scientific evidence to support the association between the surgical technique and implant stability. Purpose. This review aimed to investigate the influence of different surgical techniques including the undersized drilling, the osteotome, the piezosurgery, the flapless procedure, and the bone stimulation by low-level laser therapy on the primary and/or secondary stability of dental implants. Materials and methods. A search of PubMed, Cochrane Library, and grey literature was performed. The inclusion criteria comprised observational clinical studies and randomized controlled trials (RCTs) conducted in patients who received dental implants for rehabilitation, studies that evaluated the association between the surgical technique and the implant primary and/or secondary stability. The articles selected were carefully read and classified as low, moderate, and high methodological quality and data of interest were tabulated. Results. Eight clinical studies were included then they were classified as moderate or high methodological quality and control of bias. Conclusions. There is a weak evidence suggesting that any of previously mentioned surgical techniques could influence the primary and/or secondary implant stability. PMID:25126094

  12. [Dental implant restoration abutment selection].

    PubMed

    Bin, Shi; Hao, Zeng

    2017-04-01

    An increasing number of implant restoration abutment types are produced with the rapid development of dental implantology. Although various abutments can meet different clinical demands, the selection of the appropriate abutment is both difficult and confusing. This article aims to help clinicians select the appropriate abutment by describing abutment design, types, and selection criteria.

  13. Clinical evaluation of a novel dental implant system as single implants under immediate loading conditions - 4-month post-loading results from a multicentre randomised controlled trial.

    PubMed

    Esposito, Marco; Trullenque-Eriksson, Anna; Blasone, Rodolfo; Malaguti, Giuliano; Gaffuri, Cristiano; Caneva, Marco; Minciarelli, Armando; Luongo, Giuseppe

    To evaluate the safety and clinical effectiveness of a novel dental implant system (GENESIS Implant System, Keystone Dental, Massachusetts, USA) using another dental implant system by the same manufacturer as a control (PRIMA Implant System, Keystone Dental). A total of 53 patients requiring at least two single crowns had their sites randomised according to a split-mouth design to receive both implant systems at six centres. If implants could be placed with a torque superior to 40 Ncm they were to be loaded immediately with provisional crowns, otherwise after 3 months of submerged healing. Provisional crowns were replaced by definitive crowns 4 months after initial loading, when the follow-up period for the initial part of this study was completed. Outcome measures were crown/implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, plaque score, marginal bleeding, patients and preference of the clinician. In total 53 PRIMA and 53 GENESIS implants were placed. Three patients dropped out but all of the remaining patients were followed up to 4-months post-loading. No PRIMA implant failed whereas four GENESIS implants failed. Only two complications were reported for PRIMA implants. There were no statistically significant differences for crown/implant failures (difference in proportions = 0.080; P (McNemar test) = 0.125) and complications (difference in proportions = -0.04; P (McNemar test) = 0.500) between the implant systems. There were no differences at 4-months post-loading for plaque (difference = -0.54, 95% CI: -3.01 to 1.93; P (Paired t-test) = 0.660), marginal bleeding (difference = -3.8, 95% CI: -7.63 to 0.019; P (Paired t-test) = 0.051), PES (difference = 0.47, 95% CI: -0.56 to 1.50; P (Paired t-test) = 0.365) and marginal bone level changes (difference in mm = -0.04, 95% CI: -0.33 to 0.26; P (Paired t-test) = 0.795). The majority of the patients (46) had no preference regarding the two implant systems evaluated. Three operators preferred GENESIS implants, two had no preference and one preferred GENESIS in medium and soft bone and PRIMA in hard bone. No statistically significant differences were observed between the systems' implant types, although four GENESIS implants failed versus none of the PRIMA type. Longer follow-ups of wider patient populations are needed to better understand whether there is an effective advantage with one of the two implant designs. Conflict-of-interest statement: This research project was originally funded by Keystone Italia, Dental spa (Verona, Italy), the manufacturer of the implants evaluated in this investigation. 
 
However, when Keystone Italia received the data of the present manuscript, they refused to honour the financial agreement for the present publication. Therefore, no further follow-ups of this trial will be considered. A legal action was initiated against Keystone Italia. The data belonged to the authors and by no means was the manufacturer allowed to interfere with the conduct of the trial or the publication of the results.

  14. Regenerative Surgical Treatment of Peri-implantitis

    ClinicalTrials.gov

    2016-08-31

    Failure of Dental Implant Due to Infection; Infection; Inflammation; Peri-implantitis; Bacterial Infections; Bleeding of Subgingival Space; Molecular Sequence Variation; Periodontal Diseases; Mouth Diseases

  15. A strontium-incorporated nanoporous titanium implant surface for rapid osseointegration

    NASA Astrophysics Data System (ADS)

    Zhang, Wenjie; Cao, Huiliang; Zhang, Xiaochen; Li, Guanglong; Chang, Qing; Zhao, Jun; Qiao, Yuqin; Ding, Xun; Yang, Guangzheng; Liu, Xuanyong; Jiang, Xinquan

    2016-02-01

    Rapid osseointegration of dental implants will shorten the period of treatment and enhance the comfort of patients. Due to the vital role of angiogenesis played during bone development and regeneration, it might be feasible to promote rapid osseointegration by modifying the implant surface to gain a combined angiogenesis/osteogenesis inducing capacity. In this study, a novel coating (MAO-Sr) with strontium-incorporated nanoporous structures on titanium implants was generated via a new micro-arc oxidation, in an attempt to induce angiogenesis and osteogenesis to enhance rapid osseointegration. In vitro, the nanoporous structure significantly enhanced the initial adhesion of canine BMSCs. More importantly, sustained release of strontium ions also displayed a stronger effect on the BMSCs in facilitating their osteogenic differentiation and promoting the angiogenic growth factor secretion to recruit endothelial cells and promote blood vessel formation. Advanced mechanism analyses indicated that MAPK/Erk and PI3K/Akt signaling pathways were involved in these effects of the MAO-Sr coating. Finally, in the canine dental implantation study, the MAO-Sr coating induced faster bone formation within the initial six weeks and the osseointegration effect was comparable to that of the commercially available ITI implants. These results suggest that the MAO-Sr coating has the potential for future use in dental implants.Rapid osseointegration of dental implants will shorten the period of treatment and enhance the comfort of patients. Due to the vital role of angiogenesis played during bone development and regeneration, it might be feasible to promote rapid osseointegration by modifying the implant surface to gain a combined angiogenesis/osteogenesis inducing capacity. In this study, a novel coating (MAO-Sr) with strontium-incorporated nanoporous structures on titanium implants was generated via a new micro-arc oxidation, in an attempt to induce angiogenesis and osteogenesis to enhance rapid osseointegration. In vitro, the nanoporous structure significantly enhanced the initial adhesion of canine BMSCs. More importantly, sustained release of strontium ions also displayed a stronger effect on the BMSCs in facilitating their osteogenic differentiation and promoting the angiogenic growth factor secretion to recruit endothelial cells and promote blood vessel formation. Advanced mechanism analyses indicated that MAPK/Erk and PI3K/Akt signaling pathways were involved in these effects of the MAO-Sr coating. Finally, in the canine dental implantation study, the MAO-Sr coating induced faster bone formation within the initial six weeks and the osseointegration effect was comparable to that of the commercially available ITI implants. These results suggest that the MAO-Sr coating has the potential for future use in dental implants. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08580b

  16. Early implant placement for a patient with ectodermal dysplasia: Thirteen years of clinical care.

    PubMed

    Knobloch, Lisa A; Larsen, Peter E; Saponaro, Paola C; L'Homme-Langlois, Emilie

    2017-11-29

    Patients with ectodermal dysplasia have abnormalities of 2 or more structures that originate from the ectoderm. The oral manifestations often include the congenital absence of teeth and malformed teeth. This clinical report describes the interdisciplinary care from childhood through the definitive dental rehabilitation completed at skeletal maturation to replace the missing teeth in a patient with ectodermal dysplasia. Treatment began at 9 years of age with an implant-assisted mandibular overdenture to improve function and replace the missing mandibular teeth. Orthodontic treatment for the consolidation of space, composite resin restorations, and interim removable dental prostheses were provided to improve esthetics and replace the missing maxillary teeth. Skeletal growth was monitored, and orthognathic surgery was performed at the cessation of growth. The definitive rehabilitation consisted of a mandibular fixed dental prosthesis supported by dental implants and a maxillary removable dental prosthesis to restore the patient to esthetics and function. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Bioengineered Tooth Buds Exhibit Features of Natural Tooth Buds.

    PubMed

    Smith, E E; Angstadt, S; Monteiro, N; Zhang, W; Khademhosseini, A; Yelick, P C

    2018-06-01

    Tooth loss is a significant health issue currently affecting millions of people worldwide. Artificial dental implants, the current gold standard tooth replacement therapy, do not exhibit many properties of natural teeth and can be associated with complications leading to implant failure. Here we propose bioengineered tooth buds as a superior alternative tooth replacement therapy. We describe improved methods to create highly cellularized bioengineered tooth bud constructs that formed hallmark features that resemble natural tooth buds such as the dental epithelial stem cell niche, enamel knot signaling centers, transient amplifying cells, and mineralized dental tissue formation. These constructs were composed of postnatal dental cells encapsulated within a hydrogel material that were implanted subcutaneously into immunocompromised rats. To our knowledge, this is the first report describing the use of postnatal dental cells to create bioengineered tooth buds that exhibit evidence of these features of natural tooth development. We propose future bioengineered tooth buds as a promising, clinically relevant tooth replacement therapy.

  18. Sprue Design and Its Effect on the Castability and Porosity of Titanium Removable Partial Denture Frameworks

    DTIC Science & Technology

    1997-06-10

    been in the area of implantology . Recent advances in dental titanium casting machines allow for the use of titanium for crowns, fixed partial dentures...medical implant prostheses (McKinney and Lemons, 1985; Williams, 1981). By the end of the 1960s, titanium found a niche in dental implantology ...as an implant or restorative material. In the field of dental implantology , evidence suggests that metal corrosion and allergenicity may be important

  19. Full-arch implant-retained prosthetics in general dental practice.

    PubMed

    Rosenbaum, Nigel

    2012-03-01

    The loss of all teeth from one or both dental arches is a significant disability affecting self-confidence, communication, masticatory function and aesthetics. Whilst missing teeth cannot be restored to the natural state, the development of a prosthetic dentition has been a goal of dental science throughout the centuries. Contemporary techniques allow for the replacement of missing dentition with fixed or removable solutions, solving many of the problems. Implant dentistry has transformed this area of medicine. This article provides dental practitioners with an overview of this important area of patient care. Dental practitioners in clinical practice will frequently see edentulism; a good understanding of the available options for rehabilitation is essential.

  20. Apical and marginal bone alterations around implants in maxillary sinus augmentation grafted with autogenous bone or bovine bone material and simultaneous or delayed dental implant positioning.

    PubMed

    Sbordone, Ludovico; Levin, Liran; Guidetti, Franco; Sbordone, Carolina; Glikman, Ari; Schwartz-Arad, Devorah

    2011-05-01

    A re-pneumatization phenomenon was recorded in sinuses grafted with different materials. The specific aims of this paper were to assess the dental implant survival rate and the behavior of marginal and apical bone remodeling around dental implants placed following sinus augmentation. A retrospective study was conducted on consecutive patients treated in two surgical centers. Different surgical techniques were adopted for sinus augmentation: simultaneous or delayed dental implant insertion with bovine bone-material augmentation or autologous bone grafting (chin and iliac crest). Survival rates were recorded for the overall number of implants (patients of group A). Apical and marginal bone levels (ABL and MBL, respectively) were radiographically measured, and statistical analysis was performed in implants of a subgroup of patients (group B). A total of 282 dental implants were positioned. Recorded cumulative survival rates (CSRs) were 95.6% and 100% for autogenous and bovine bone material, respectively, while CSRs at 2-year follow-up for immediate and delayed procedures were 99.3% and 96.5%. For the subgroup B, 57 sinus augmentation procedures were performed in 39 patients, with the positioning of 154 implants. Generally, the apical- and marginal-bone resorption of the bovine bone-material group was less than that of the autogenous group. The differences between the ABL values of the bovine bone-material and iliac-crest groups were statistically significant at 1 year, whereas this significance disappeared at the 2-year follow-up; tests showed that a statistical difference was recorded in the bovine bone-material group between the 1- and 2-year follow-ups. With regard to MBL comparisons between simultaneous and delayed implantation, the differences maintained their significance at the 2-year follow-up also. Differences regarding apical bone alteration between autogenous bone from the iliac crest and bovine bone material at the 1- and 2-year follow-ups, as well as in the bovine bone-material group between the 1- and 2-year follow-ups, attested to slower but more prolonged physiologic bone remodeling in the bovine-graft-material group than in the autogenous-bone group. The MBL analysis showed that remodeling in the delayed implant group demonstrated a greater resorption in the cervical portion than was seen in the simultaneous implant group. © 2010 John Wiley & Sons A/S.

  1. Reconstruction of attached soft tissue around dental implants by acelluar dermal matrix grafts and resin splint

    PubMed Central

    Liu, Changying; Su, Yucheng; Tan, Baosheng; Ma, Pan; Wu, Gaoyi; Li, Jun; Geng, Wei

    2014-01-01

    Objectives: The purpose of this study was to recommend a new method using acellular dermal matrix graft and resin splint to reconstruct the attached soft tissue around dental implants in patients with maxillofacial defects. Materials and methods: Total 8 patients (3 male and 5 female patients) diagnosed with maxillofacial defects and dentition defects caused by tumors, fractures or edentulous jaw, were selected for this study. Dental implants were routinely implanted at the edentulous area. Acellular dermal matrix heterografts and resin splint were used to increase the attached soft tissue. The width of attached gingiva in the labial or buccal surface at edentulous area was measured before surgical procedures and after the completion of superstructures. Paired t-test was applied to assess the change of quantitative variables. All tests were 2-tailed, and P < 0.05 was considered statistically significant. Results: The dense connective tissue around implants could be reconstructed one month after the completion of surgical procedures, and the epithelial cuff around the implant neck established very well. The width of attached gingival tissue in the patients increased significantly from a mean of 0.61 ± 0.75 mm to 6.25 ± 1.04 mm. The patients were fully satisfied with the esthetic and functional results achieved. Conclusions: The acellular dermal matrix graft could be used to increase the attached gingiva around dental implants in these patients with maxillofacial defects. The resin splint could facilitate the healing of graft. PMID:25663964

  2. A Novel Scheme and Evaluations on a Long-Term and Continuous Biosensor Platform Integrated with a Dental Implant Fixture and Its Prosthetic Abutment

    PubMed Central

    Li, Yu-Jung; Lu, Chih-Cheng

    2015-01-01

    A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD) enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis, diagnosis, drug release and even healthcare technologies. PMID:26404283

  3. A Novel Scheme and Evaluations on a Long-Term and Continuous Biosensor Platform Integrated with a Dental Implant Fixture and Its Prosthetic Abutment.

    PubMed

    Li, Yu-Jung; Lu, Chih-Cheng

    2015-09-25

    A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD) enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis, diagnosis, drug release and even healthcare technologies.

  4. Botulinum Toxin Type A as Preoperative Treatment for Immediately Loaded Dental Implants Placed in Fresh Extraction Sockets for Full-Arch Restoration of Patients With Bruxism.

    PubMed

    Mijiritsky, Eitan; Mortellaro, Carmen; Rudberg, Omri; Fahn, Miri; Basegmez, Cansu; Levin, Liran

    2016-05-01

    The aim of the present report was to describe the use of Botulinum toxin type A as preoperative treatment for immediately loaded dental implants placed in fresh extraction sockets for full-arch restoration of patients with bruxism. Patients with bruxism who were scheduled to receive immediately loaded full-arch implant supported fixed restorations were included in this retrospective clinical report. To reduce the occlusal forces applied in patients with bruxism, Botulinum toxin type A was introduced prior to the implant placement procedure. Patients were followed and implant survival as well as peri-implant bone level was assessed in each periodic follow-up visit. Adverse effects were also recorded. A control group with no use of Botulinum toxin was evaluated as well. A total of 26 patients (13 test and 13 control), with bruxism, aged 59.15 ± 11.43 years on average were included in this retrospective report and received immediately loaded dental implants placed in fresh extraction sockets for full-arch restoration. The test group treatment preceded by Botulinum toxin type A injection. Maxillary arches were supported by 8 to 10 implants while the mandibular arch was supported by 6 implants. All surgeries went uneventfully and no adverse effects were observed. The average follow-up time was 32.5 ± 10.4 months (range, 18-51). In the test group, no implant failures were recorded. One patient presented with 1 to 2 mm bone loss around 4 of the implants; the other implants presented with stable bone level. In the control group 1 patient lost 2 implants and another demonstrated 2 mm bone loss around 3 of the implants. The preoperative use of Botulinum toxin in patients with bruxism undergoing full-arch rehabilitation using immediately loaded dental implants placed in fresh extraction sockets seems to be a technique that deserves attention. Further long-term, large-scale randomized clinical trials will help to determine the additional benefit of this suggested treatment modality.

  5. Evaluating the clinical and esthetic outcome of apically positioned flap technique in augmentation of keratinized gingiva around dental implants

    PubMed Central

    Reddy, Vineela Katam; Parthasarathy, Harinath; Lochana, Priya

    2013-01-01

    Purpose: Dental implants though a successful treatment modality there exists controversies regarding the relationship between the adequacy of the keratinized gingiva (KG) and peri-implant health. The presence of an adequate amount of peri-implant KG reduces gingival inflammation and hence soft-tissue augmentation should be frequently considered. Among the various periodontal plastic surgical procedures, the apically displaced flap increases the width of keratinized tissue with reduced patient morbidity. The current study aims at evaluating the esthetic improvement in KG around dental implants applying apically positioned flap (APF) technique. Materials and Methods: A total of 10 endosseous dental implants were placed in eight systemically healthy patients. APF surgery was performed at the implant site on the buccal aspect either at the time of implant placement (one stage surgical protocol) or during the implant recovery stage (two stage surgical protocols) for increasing the width of KG and reviewed until 12 weeks post-operatively. The width of KG was evaluated at baseline and at the end of 12 weeks after surgery. Paired t-test was performed to evaluate the changes in the width of KG at baseline and at 12 weeks post-operatively. In addition, soft-tissue esthetic outcome was assessed by using visual analog scale (VAS). Results: The mean width of KG at baseline was 1.47 mm and 12 weeks post-operatively was 5.42 mm. The gain in KG from baseline was 3.95 mm with the P value of 0.000, which was highly statistically significant. The assessment of esthetic outcome using VAS gave an average score of 7.1 indicating good esthetics. Conclusion: The technique of APF yielded a significant improvement in keratinized tissue, which is both functionally and esthetically acceptable. PMID:24124297

  6. Economic evaluation of single-tooth replacement: dental implant versus fixed partial denture.

    PubMed

    Kim, Younhee; Park, Joo-Yeon; Park, Sun-Young; Oh, Sung-Hee; Jung, YeaJi; Kim, Ji-Min; Yoo, Soo-Yeon; Kim, Seong-Kyun

    2014-01-01

    This study assessed the cost-effectiveness from a societal perspective of a dental implant compared with a three-unit tooth-supported fixed partial denture (FPD) for the replacement of a single tooth in 2010. A decision tree was developed to estimate cost-effectiveness over a 10-year period. The survival rates of single-tooth implants and FPDs were extracted from a meta-analysis of single-arm studies. Medical costs included initial treatment costs, maintenance costs, and costs to treat complications. Patient surveys were used to obtain the costs of the initial single-tooth implant or FPD. Maintenance costs and costs to treat complications were based on surveys of seven clinical experts at dental clinics or hospitals. Transportation costs were calculated based on the number of visits for implant or FPD treatment. Patient time costs were estimated using the number of visits and time required, hourly wage, and employment rate. Future costs were discounted by 5% to convert to present values. The results of a 10-year period model showed that a single dental implant cost US $261 (clinic) to $342 (hospital) more than an FPD and had an average survival rate that was 10.4% higher. The incremental cost-effectiveness ratio was $2,514 in a clinic and $3,290 in a hospital for a prosthesis in situ for 10 years. The sensitivity analysis showed that initial treatment costs and survival rate influenced the cost-effectiveness. If the cost of an implant were reduced to 80% of the current cost, the implant would become the dominant intervention. Although the level of evidence for effectiveness is low, and some aspects of single-tooth implants or FPDs, such as satisfaction, were not considered, this study will help patients requiring single-tooth replacement to choose the best treatment option.

  7. Can the use of antibiotics interfere with the success of dental osseointegrated implants in diabetic patients?

    PubMed

    Borba, Alexandre Meireles; Souza, Daniel Falbo Martins; Brozoski, Mariana Aparecida; Burim, Rafael Augusto; Naclério-Homem, Maria da Graça; Deboni, Maria Cristina Zindel

    2013-11-01

    The present review aims to discuss the last 10 years published data on the topic of the use of osseointegrated implants in diabetic subjects, particularly regarding the influence of antibiotics administration in the perioperative period. In the last decades, oral rehabilitation significantly has evolved particularly with the use of osseointegrated implants. Increased life expectation of population is reflecting in a greater number of diabetic patients who might require dental osseointegrated implants rehabilitation. Diabetes was considered for a long time as a contraindication for oral implant placement. In this context, the use of antibiotics is still a controversial factor when we correlate it to implant success rate. Although 228 articles were initially selected for evaluation of proposed criteria, only 16 articles were considered valid. Among the 16 selected articles, only six articles represented clinical research that discussed the influence of the antibiotic in the success of osseointegration of dental implants in diabetic subjects. Five were retrospective studies and one a prospective research. Data favors the use of antibiotics without significant side effects but clinical investigations of the need of prophylaxis antibiotic or therapeutic antibiotics are still scarce. The lack of adequate methodology is one of the main problems of the current articles. It is important to emphasize that studies should present detailed methodology in order to allow reproducibility. Permanent tooth loss is a pathological condition that affects millions of people worldwide. The possibility of successful treatment of edentulous areas through osseointegrated implants in those systemic compromised patients is a matter of scientific discussion. Although antimicrobial agents must be used rationally and carefully to avoid development of bacterial resistance, more studies are needed in order to support evidence regarding the influence of antibiotics in the success of dental implant surgery in diabetic patients.

  8. Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

    PubMed

    Mishra, Sunil Kumar; Chowdhary, Ramesh

    2014-06-01

    Osseointegration is the more stable situation and results in a high success rate of dental implants. Heat generation during rotary cutting is one of the important factors influencing the development of osseointegration. To assess the various factors related to implant drills responsible for heat generation during osteotomy. To identify suitable literature, an electronic search was performed using Medline and Pubmed database. Articles published in between 1960 to February 2013 were searched. The search is focused on heat generated by dental implant drills during osteotomy. Various factors related to implant drill such effect of number of blades; drill design, drill fatigue, drill speed and force applied during osteotomies which were responsible for heat generation were reviewed. Titles and abstracts were screened, and literature that fulfilled the inclusion criteria was selected for a full-text reading. The initial literature search resulted in 299 articles out of which only 70 articles fulfils the inclusion criteria and were included in this systematic review. Many factors related to implant drill responsible for heat generation were found. Successful preparation of an implant cavity with minimal damage to the surrounding bone depends on the avoidance of excessive temperature generation during surgical drilling. The relationship between heat generated and implant drilling osteotomy is multifactorial in nature and its complexity has not been fully studied. Lack of scientific knowledge regarding this issue still exists. Further studies should be conducted to determine the various factors which generate less heat while osteotomy such as ideal ratio of force and speed in vivo, exact time to replace a drill, ideal drill design, irrigation system, drill-bone contact area.

  9. A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia

    PubMed Central

    Osman, Reham B.; Swain, Michael V.

    2015-01-01

    The goal of the current publication is to provide a comprehensive literature review on the topic of dental implant materials. The following paper focuses on conventional titanium implants and more recently introduced and increasingly popular zirconia implants. Major subtopics include the material science and the clinical considerations involving both implant materials and the influence of their physical properties on the treatment outcome. Titanium remains the gold standard for the fabrication of oral implants, even though sensitivity does occur, though its clinical relevance is not yet clear. Zirconia implants may prove to be promising in the future; however, further in vitro and well-designed in vivo clinical studies are needed before such a recommendation can be made. Special considerations and technical experience are needed when dealing with zirconia implants to minimize the incidence of mechanical failure. PMID:28787980

  10. Electromagnetic irradiation may be a new approach to therapy for peri-implantitis.

    PubMed

    Cao, Zhensheng; Chen, Yijia; Chen, Yuxue; Zhao, Qing; Xu, Xiaomei; Chen, Yangxi

    2012-03-01

    Peri-implantitis can lead to bone destruction around a dental implant through inflammation and immune reactions caused by bacteria adhering to the surface of the implant abutment. Electromagnetic irradiation can inhibit bacterial growth, increase bone formation, decrease bone resorption and reduce the inflammatory response. Our hypothesis is that electromagnetic irradiation may be a new treatment approach for peri-implantitis and may simultaneously maintain bone mass around the dental implant. The results would be more significant when combined with other agents, because the effect of some antibiotics and anti-inflammatory drugs is strengthened by electromagnetic irradiation. This non-invasive therapy is expected to be conducted in a convenient manner, and even by patients at home, thereby facilitating the prevention and treatment of peri-implantitis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Osseointegration of Plateau Root Form Implants: Unique Healing Pathway Leading to Haversian-Like Long-Term Morphology.

    PubMed

    Coelho, Paulo G; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Gil, Luis F; Tovar, Nick; Jimbo, Ryo; Neiva, Rodrigo; Bonfante, Estevam A

    2015-01-01

    Endosteal dental implants have been utilized as anchors for dental and orthopedic rehabilitations for decades with one of the highest treatment success rates in medicine. Such success is due to the phenomenon of osseointegration where after the implant surgical placement, bone healing results into an intimate contact between bone and implant surface. While osseointegration is an established phenomenon, the route which osseointegration occurs around endosteal implants is related to various implant design factors including surgical instrumentation and implant macro, micro, and nanometer scale geometry. In an implant system where void spaces (healing chambers) are present between the implant and bone immediately after placement, its inherent bone healing pathway results in unique opportunities to accelerate the osseointegration phenomenon at the short-term and its maintenance on the long-term through a haversian-like bone morphology and mechanical properties.

  12. Release of titanium after insertion of dental implants with different surface characteristics – an ex vivo animal study

    PubMed Central

    Pettersson, Mattias; Pettersson, Jean; Molin Thorén, Margareta; Johansson, Anders

    2017-01-01

    Abstract In the present study, amount of titanium (Ti) released into the surrounding bone during placement of implants with different surface structure was investigated. Quantification of Ti released during insertion from three different implants was performed in this ex vivo study. Jaw bone from pigs was used as model for installation of the implants and Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) was used for analysis of the released Ti. Implant surface were examined with scanning electron microscopy (SEM), before and after the placement into the bone. Ti was abraded to the surrounding bone upon insertion of a dental implant and the surface roughness of the implant increased the amount of Ti found. Diameter and total area of the implant were of less importance for the Ti released to the bone. No visible damages to the implant surfaces could be identified in SEM after placement. PMID:29242814

  13. Comparison of Subgingival and Peri-implant Microbiome in Chronic Periodontitis.

    PubMed

    Zhang, Qian; Qin, Xue Yan; Jiang, Wei Peng; Zheng, Hui; Xu, Xin Li; Chen, Feng

    2015-09-01

    To analyse the microbia composition of 10 healthy dental implants and 10 chronic periodontitis patients. Subgingival plaque and peri-implant biofilm were sampled at the first molar site before and after implant restoration. The analysis was conducted by 454-prosequencing of bacterial V1 to V3 regions of 16S rDNA. Chronic periodontitis subjects showed greater bacterial diversity compared with implant subjects. The relative abundance of sixteen genera and twelve species differed significantly between implant and chronic periodontitis subjects. The genera Catonella, Desulfovibrio, Mogibacterium, Peptostreptococcus and Propionibacterium were present in higher abundance in chronic periodontitis subjects, while implant subjects had higher proportions of Brevundimonas and Pseudomonas species. Our results demonstrate that implant restoration changes the oral microbiota. The analysis suggests that periodontal bacteria can remain for a prolonged period of time at non-dental sites, from where they can colonise the peri-implant.

  14. Impact of Different Surgeons on Dental Implant Failure.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    To assess the influence of several factors on the prevalence of dental implant failure, with special consideration of the placement of implants by different dental surgeons. This retrospective study is based on 2,670 patients who received 10,096 implants at one specialist clinic. Only the data of patients and implants treated by surgeons who had inserted a minimum of 200 implants at the clinic were included. Kaplan-Meier curves were stratified with respect to the individual surgeon. A generalized estimating equation (GEE) method was used to account for the fact that repeated observations (several implants) were placed in a single patient. The factors bone quantity, bone quality, implant location, implant surface, and implant system were analyzed with descriptive statistics separately for each individual surgeon. A total of 10 surgeons were eligible. The differences between the survival curves of each individual were statistically significant. The multivariate GEE model showed the following variables to be statistically significant: surgeon, bruxism, intake of antidepressants, location, implant length, and implant system. The surgeon with the highest absolute number of failures was also the one who inserted the most implants in sites of poor bone and used turned implants in most cases, whereas the surgeon with the lowest absolute number of failures used mainly modern implants. Separate survival analyses of turned and modern implants stratified for the individual surgeon showed statistically significant differences in cumulative survival. Different levels of failure incidence could be observed between the surgeons, occasionally reaching significant levels. Although a direct causal relationship could not be ascertained, the results of the present study suggest that the surgeons' technique, skills, and/or judgment may negatively influence implant survival rates.

  15. Immediate prosthesis over implants retained using abutments with flexible screws: A preliminary study

    PubMed Central

    Peñarrocha-Oltra, David; Serra-Pastor, Blanca; Balaguer-Martí, José-Carlos; Agustín-Panadero, Rubén

    2017-01-01

    Background Immediate loading protocols for the rehabilitation of edentulous or partially edentulous patients have become very popular, due to the conveniences they afford in comparison with conventional loading techniques. Material and Methods A preliminary study was carried out with 8 patients subjected to dental implant treatment with an immediate loading protocol involving a novel system of abutments with flexible screws. Implant survival was analyzed, together with marginal bone loss and patient and dentist satisfaction. Results A total of 35 implants were subjected to immediate loading using the abutments with flexible screws. The mean patient and dentist satisfaction score was 9.1 and 8.5, respectively. After 12 months the dental implant survival rate was 95.8%, with a mean marginal bone loss of 0.51 ± 0.12 mm. Conclusions The novel system of abutments with flexible screws offers a good alternative to conventional immediate loading, since it allows rapid and simple manufacture of a reliable passive fit, fixed interim prosthesis after surgery. Key words:Dental implants, Flexafit®, Immediate loading, Immediate prosthesis. PMID:29410752

  16. A residual granuloma in association with a dental implant.

    PubMed

    McCracken, Michael S; Chavali, Ramakiran V; Al-Naief, Nasser Said; Eleazer, Paul D

    2012-04-01

    At times, dental implants are placed into sites with a history of periapical pathology. Sometimes the infection is active, and other times the tooth may have been extracted years before implant placement. In either case, the possibility exists for long-term residual cysts or infections that can negatively impact the prognosis of the implant. In this case report, an implant is placed into a healed mandibular ridge several months after extraction of the tooth. A radiolucency was noted on routine radiographic examination 2 years later. Surgical inspection and histology revealed a periapical granuloma with acute and chronic inflammatory cells. After surgical curettage of the site, the patient healed without complication. Implants may develop apical pathology as a result of a preexisting long-term residual infection.

  17. Zygomatic implant-retained fixed complete denture for an elderly patient.

    PubMed

    Baig, Mirza Rustum; Rajan, Gunaseelan; Yunus, Norsiah

    2012-06-01

    Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  18. Induction of periimplantitis in dental implants.

    PubMed

    Becker, Stephan T; Föge, Marc; Beck-Broichsitter, Benedicta E; Gavrilova, Olga; Bolte, Hendrik; Rosenstiel, Philipp; Wiltfang, Jörg

    2013-01-01

    Development, progression, and therapy of periimplantitis are nonresolved emerging problems. The aim of this pilot study was to establish a model for periimplantitis in mice to have a base for tests with immune-deficient knockout organisms to improve the knowledge about development and progression of periimplantitis and to develop further therapeutic options.In 8 mice, titanium implants were inserted in the median of the palate. Four of these implants had ligatures (periimplantitis group). After 2 weeks, the animals received a special diet enriched with sugar and flavor. After 9 weeks, micro-computed tomography (micro-CT) examinations to evaluate the periimplant tissue and histologies were performed.Dental implant insertions within the oral cavity are possible in living mice. Implants with ligatures showed significantly larger periimplant bone defects than controls. The radiologic findings were confirmed by histology. At the end of the observation period, the portion of implants lost was higher in the ligature group.This is the first publication to describe the insertion of dental implants in living mice. In addition, it is the first time that periimplant infection could be induced in that species. This model will pave the way to study knockout mice with reduced or even enhanced resistance to periimplantitis.

  19. Injury of the Inferior Alveolar Nerve during Implant Placement: a Literature Review

    PubMed Central

    Wang, Hom-Lay; Sabalys, Gintautas

    2011-01-01

    ABSTRACT Objectives The purpose of present article was to review aetiological factors, mechanism, clinical symptoms, and diagnostic methods as well as to create treatment guidelines for the management of inferior alveolar nerve injury during dental implant placement. Material and Methods Literature was selected through a search of PubMed, Embase and Cochrane electronic databases. The keywords used for search were inferior alveolar nerve injury, inferior alveolar nerve injuries, inferior alveolar nerve injury implant, inferior alveolar nerve damage, inferior alveolar nerve paresthesia and inferior alveolar nerve repair. The search was restricted to English language articles, published from 1972 to November 2010. Additionally, a manual search in the major anatomy, dental implant, periodontal and oral surgery journals and books were performed. The publications there selected by including clinical, human anatomy and physiology studies. Results In total 136 literature sources were obtained and reviewed. Aetiological factors of inferior alveolar nerve injury, risk factors, mechanism, clinical sensory nerve examination methods, clinical symptoms and treatment were discussed. Guidelines were created to illustrate the methods used to prevent and manage inferior alveolar nerve injury before or after dental implant placement. Conclusions The damage of inferior alveolar nerve during the dental implant placement can be a serious complication. Clinician should recognise and exclude aetiological factors leading to nerve injury. Proper presurgery planning, timely diagnosis and treatment are the key to avoid nerve sensory disturbances management. PMID:24421983

  20. Dental implant imaging: TeraRecon's Dental 3D Cone Beam Computed Tomography System.

    PubMed

    Garg, Arun K

    2007-06-01

    Early in the development of implant technology, conventional dental imaging techniques were limited for evaluating the patient for implant surgery. During the treatment-planning phase, the recipient bed is routinely assessed by visual examination and palpation, as well as by periapical and panoramic radiology. These two imaging modalities provide a two-dimensional image of the mesiodistal and occlusoapical dimensions of the edentulous regions where the implants might be placed. When adequate occlusoapical bone height is available for endosteal implants, the buccolingual width and angulation of the available bone are the most important criteria for implant selection and success. However, neither buccolingual width nor angulation can be visualized on most traditional radiographs. Although clinical examination and traditional radiographs may be adequate for patients with wide residual ridges that exhibit sufficient bone crestal to the mandibular nerve and maxillary sinus, these methods do not allow for the precise measurement of the buccolingual dimension of the bone or assessment of the location of unanticipated undercuts. Because of these concerns, it is necessary to view the recipient site in a plane through the arch of the maxilla or mandible in the region of the proposed implants. Implant surgeons soon recognized that, for the optimum placement of implants, cross-sectional views of the maxilla and mandible are the ideal means for providing necessary preoperative information. For complex cases where multiple implants are required or where anatomical measurements are crucial, but also increasingly for more routine cases, more and more clinicians are recommending CT scan imaging procedure such as that offered by TeraRecon's Dental CBCT system. Because of its ability to reconstruct a fully three-dimensional model of the maxilla and mandible, CBCT provides a highly sophisticated format for precisely defining the jaw structure and locating critical anatomic structures. CBCT scans, in conjunction with software that renders immediate treatment plans using the most real and accurate information, provide the most precise radiographic modality currently available for the evaluation of patients for oral implants.

  1. Clinical Management of Implant Prostheses in Patients with Bruxism

    PubMed Central

    Komiyama, Osamu; Lobbezoo, Frank; De Laat, Antoon; Iida, Takashi; Kitagawa, Tsuyoshi; Murakami, Hiroshi; Kato, Takao; Kawara, Misao

    2012-01-01

    There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of dental implants is a risk factor for vertical peri-implant bone loss and/or may be detrimental for the suprastructure in implant prostheses. It has been documented that occlusal parafunction, such as, bruxism (tooth grinding and clenching) affects the outcome of implant prostheses, but there is no evidence for a causal relation between the failures and overload of dental implants. In spite of this lack of evidence, often metal restorations are preferred instead of porcelain for patients in whom bruxism is presumed on the basis of tooth wear. The purpose of this paper is to discuss the importance of the occlusal scheme used in implant restorations for implant longevity and to suggest a clinical approach and occlusal materials for implant prostheses in order to prevent complications related to bruxism. PMID:22701484

  2. EAO Supplement Working Group 4 - EAO CC 2015 Short implants versus sinus lifting with longer implants to restore the posterior maxilla: a systematic review.

    PubMed

    Thoma, D S; Zeltner, M; Hüsler, J; Hämmerle, C H F; Jung, R E

    2015-09-01

    To compare short implants in the posterior maxilla to longer implants placed after or simultaneously with sinus floor elevation procedures. The focused question was as follows: Are short implants superior to longer implants in the augmented sinus in terms of survival and complication rates of implants and reconstructions, patient-reported outcome measures (PROMs) and costs? A MEDLINE search (1990-2014) was performed for randomized controlled clinical studies comparing short implants (≤8 mm) to longer implants (>8 mm) in augmented sinus. The search was complimented by an additional hand search of the selected papers and reviews published between 2011 and 2014. Eligible studies were selected based on the inclusion criteria, and quality assessments were conducted. Descriptive statistics were applied for a number of outcome measures. Survival rates of dental implants were pooled simply in case of comparable studies. Eight randomized controlled clinical trials (RCTs) comparing short implants versus longer implants in the augmented sinus derived from an initial search count of 851 titles were selected and data extracted. In general, all studies were well conducted with a low risk of bias for the majority of the analyzed parameters. Based on the pooled analyses of longer follow-ups (5 studies, 16-18 months), the survival rate of longer implants amounted to 99.5% (95% CI: 97.6-99.98%) and for shorter implants to 99.0% (95% CI: 96.4-99.8%). For shorter follow-ups (3 studies, 8-9 months), the survival rates of longer implants are 100% (95% CI: 97.1-100%) and for shorter implants 98.2% (95% CI: 93.9-99.7%). Complications were predominantly of biological origin, mainly occurred intraoperatively as membrane perforations, and were almost three times as higher for longer implant in the augmented sinus compared to shorter implants. PROMs, morbidity, surgical time and costs were generally in favor of shorter dental implants. All studies were performed by surgeons in specialized clinical settings. The outcomes of the survey analyses demonstrated predictably high implant survival rates for short implants and longer implants placed in augmented sinus and their respective reconstructions. Given the higher number of biological complications, increased morbidity, costs and surgical time of longer dental implants in the augmented sinus, shorter dental implants may represent the preferred treatment alternative. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Comprehensive rehabilitation using dental implants in generalized aggressive periodontitis

    PubMed Central

    Ramesh, Asha; Ravi, Sheethalan; Kaarthikeyan, Gurumoorthy

    2017-01-01

    Generalized aggressive periodontitis (GAP) is a debilitating form of the disease and it results in deteriorating effects on the esthetic and functional aspects of the oral cavity. This case report describes the comprehensive rehabilitation of GAP patient using dental implants. The treatment planning involved thorough scaling and root planning (SRP) with oral hygiene instructions. The patient was motivated to adhere to a strict oral hygiene regimen following which periodontal flap surgery employing guided tissue regeneration and bone grafts was performed. Bacterial culture for anaerobic microorganisms was done using a gas pack pre- and postperiodontal treatment to confirm the effectiveness of the periodontal treatment regimen and also to proceed with dental implant placement. The rigorous maintenance program ensured the stability of the periodontium following which immediate placement of dental implants in the maxillary and mandibular anterior region was done. The fixed metal-ceramic prosthesis was fabricated in a step-by-step process and the patient was recalled on a periodic basis over a 3-year follow-up duration. This case is a testimonial to the postperiodontal treatment long-term stability with excellent patient cooperation and strict maintenance protocol. PMID:29398863

  4. Biomechanical Consequences of the Elastic Properties of Dental Implant Alloys on the Supporting Bone: Finite Element Analysis

    PubMed Central

    Chávarri-Prado, David; Jiménez-Garrudo, Antonio; Solaberrieta-Méndez, Eneko; Diéguez-Pereira, Markel; Fernández-González, Felipe J.; Dehesa-Ibarra, Borja; Monticelli, Francesca

    2016-01-01

    The objective of the present study is to evaluate how the elastic properties of the fabrication material of dental implants influence peri-implant bone load transfer in terms of the magnitude and distribution of stress and deformation. A three-dimensional (3D) finite element analysis was performed; the model used was a section of mandibular bone with a single implant containing a cemented ceramic-metal crown on a titanium abutment. The following three alloys were compared: rigid (Y-TZP), conventional (Ti-6Al-4V), and hyperelastic (Ti-Nb-Zr). A 150-N static load was tested on the central fossa at 6° relative to the axial axis of the implant. The results showed no differences in the distribution of stress and deformation of the bone for any of the three types of alloys studied, mainly being concentrated at the peri-implant cortical layer. However, there were differences found in the magnitude of the stress transferred to the supporting bone, with the most rigid alloy (Y-TZP) transferring the least stress and deformation to cortical bone. We conclude that there is an effect of the fabrication material of dental implants on the magnitude of the stress and deformation transferred to peri-implant bone. PMID:27995137

  5. Direct metal laser sintering titanium dental implants: a review of the current literature.

    PubMed

    Mangano, F; Chambrone, L; van Noort, R; Miller, C; Hatton, P; Mangano, C

    2014-01-01

    Statement of Problem. Direct metal laser sintering (DMLS) is a technology that allows fabrication of complex-shaped objects from powder-based materials, according to a three-dimensional (3D) computer model. With DMLS, it is possible to fabricate titanium dental implants with an inherently porous surface, a key property required of implantation devices. Objective. The aim of this review was to evaluate the evidence for the reliability of DMLS titanium dental implants and their clinical and histologic/histomorphometric outcomes, as well as their mechanical properties. Materials and Methods. Electronic database searches were performed. Inclusion criteria were clinical and radiographic studies, histologic/histomorphometric studies in humans and animals, mechanical evaluations, and in vitro cell culture studies on DMLS titanium implants. Meta-analysis could be performed only for randomized controlled trials (RCTs); to evaluate the methodological quality of observational human studies, the Newcastle-Ottawa scale (NOS) was used. Results. Twenty-seven studies were included in this review. No RCTs were found, and meta-analysis could not be performed. The outcomes of observational human studies were assessed using the NOS: these studies showed medium methodological quality. Conclusions. Several studies have demonstrated the potential for the use of DMLS titanium implants. However, further studies that demonstrate the benefits of DMLS implants over conventional implants are needed.

  6. Direct Metal Laser Sintering Titanium Dental Implants: A Review of the Current Literature

    PubMed Central

    Mangano, F.; Chambrone, L.; van Noort, R.; Miller, C.; Hatton, P.; Mangano, C.

    2014-01-01

    Statement of Problem. Direct metal laser sintering (DMLS) is a technology that allows fabrication of complex-shaped objects from powder-based materials, according to a three-dimensional (3D) computer model. With DMLS, it is possible to fabricate titanium dental implants with an inherently porous surface, a key property required of implantation devices. Objective. The aim of this review was to evaluate the evidence for the reliability of DMLS titanium dental implants and their clinical and histologic/histomorphometric outcomes, as well as their mechanical properties. Materials and Methods. Electronic database searches were performed. Inclusion criteria were clinical and radiographic studies, histologic/histomorphometric studies in humans and animals, mechanical evaluations, and in vitro cell culture studies on DMLS titanium implants. Meta-analysis could be performed only for randomized controlled trials (RCTs); to evaluate the methodological quality of observational human studies, the Newcastle-Ottawa scale (NOS) was used. Results. Twenty-seven studies were included in this review. No RCTs were found, and meta-analysis could not be performed. The outcomes of observational human studies were assessed using the NOS: these studies showed medium methodological quality. Conclusions. Several studies have demonstrated the potential for the use of DMLS titanium implants. However, further studies that demonstrate the benefits of DMLS implants over conventional implants are needed. PMID:25525434

  7. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    PubMed Central

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  8. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1981-07-15

    conventional dental materials,-usually gold. DOR 3 E-oIN OFt NOV 651IS OBSOLETE SECURITY CLASSIFICATION OF THIS PAGE (When Date Entered) SfECUNITY...AND FIELD by Craig R. Hassler, Robert H. Downes, and Larry G. McCoy BACKGROUND In the last several years a new generation of dental implants has evolved...34, Report No. 7, Contract No. DADA17-69-C-9181 (November, 1976). 5. Rasmussen, J. J., Karagianes, M. T., Westerman, R. B., and Marshall, R. D., " Dental

  9. Oral Rehabilitation With Orthognathic Surgery After Dental Implant Placement for Class III Malocclusion With Skeletal Asymmetry and Posterior Bite Collapse.

    PubMed

    Ohba, Seigo; Nakatani, Yuya; Kawasaki, Takako; Tajima, Nobutaka; Tobita, Takayoshi; Yoshida, Noriaki; Sawase, Takashi; Asahina, Izumi

    2015-08-01

    Increasing numbers of older patients are seeking orthognathic surgery to treat jaw deformity. However, orthodontic and orthognathic surgical treatment is difficult in cases without occlusal vertical stop. A 55-year-old man presented with Class III malocclusion and mandibular protrusion including esthetic problems and posterior bite collapse. He underwent dental implant treatment to reconstruct an occlusal vertical stop before orthognathic surgery. His occlusal function and esthetic problems improved after surgery, and his skeletal and occlusal stability has been maintained for 6 years. Dental implant placement at appropriate positions could help to determine the position of the proximal segment at orthognathic surgery and could shorten the time required to restore esthetic and occlusal function. This case demonstrates how skeletal and dental stability can be maintained long after surgery in a patient with jaw deformity and posterior bite collapse.

  10. A New Approach to Implant-Based Midface Reconstruction Following Subtotal Maxillectomy.

    PubMed

    Dawood, Andrew; Kalavrezos, Nicholas; Tanner, Susan

    2016-01-01

    This case presentation describes the reconstruction of an extensive maxillary-orbital defect following subtotal resection of the maxilla en bloc with orbital exenteration in a young adult following the diagnosis of chondrosarcoma. A new approach to composite midface reconstruction with dental implants is described, in which computer-guided surgery (CGS) was used to obliquely position dental implants interradicularly in the residual maxilla, such that the implant tips lie in close proximity to the root apices of the remaining teeth. The implants were then used to fixate a milled-titanium bar, fabricated using computer-aided design and manufacture (CAD/CAM), and provided with attachments for the stabilization and retention of a maxillary obturator.

  11. Medicolegal implications of dental implant therapy.

    PubMed

    Rees, Jonathan

    2013-04-01

    Despite the recent economic downturn, the dental implant market continues to grow year on year. Many more dentists are involved in the placement restoration of dental implants and dental implants are being placed in an extended range of clinical scenarios. Dental implant therapy remains a high risk area for the inexperienced interns of civil negligence claims and General Dental Council hearings. Risk can be mitigated by:• Ensuring appropriate indemnity • Complying with the published requirements for training • Maintaining detailed and extensive clinical records • Completing the initial phases of history, examination and investigations robustly • Recording a diagnosis • Providing a bespoke written treatment plan that includes details of the need for treatment, the treatment options (the risks and benefits), the phases of treatment, the costs of treatment,the expected normal sequelae of surgery, the risks and complications of implant therapy and the requirement for future maintenance. The provision of treatment that is different in nature or extent to that agreed can result in a breach of contract as well as a claim for negligence • Engaging sufficiently with the patient to obtain consent • Providing written postoperative instructions detailing emergency arrangements, patients who are anxious or in pain may not retain oral information • Making a frank disclosure of complication or collateral damage • Considering referral at an early stage particularly if reparative surgery is required. The stress of complications or failure may impair a dentist's normally sound judgement; there may be financial pressure, or concerns regarding reputation. In some cases, dentists avoid making a frank disclosure, feel obliged to undertake complicated reparative surgery, fail to make a timely referral, fail to respond appropriately to patient's concerns and in some cases attempt to alter the clinical records.However, in the best of hands and without negligence complications can and do occur. Complications that occur in the presence of good planning and communication and are managed appropriately do not amount to negligence, and are unlikely to lead to a successful claim.

  12. Dental materials and magnetic resonance imaging.

    PubMed

    Hubálková, Hana; Hora, Karel; Seidl, Zdenek; Krásenský, Jan

    2002-09-01

    The objective of this investigation was to evaluate the reaction of selected dental materials in the magnetic field of a magnetic resonance imaging device to determine a possible health risk. The following dental materials were tested in vitro during magnetic resonance imaging: 15 dental alloys, four dental implants, one surgical splint and two wires for fixation of maxillofacial fractures. Possible artefacts (corresponding with magnetic properties), heating and force effects were tested. Results concerning movement and heating were in agreement with the literature. The artefacts seen were significant: for the surgical splint, a spherical artefact with a diameter of 55 mm; for the wires, up to 22 mm; and for the dental blade implant, an artefact of 28 x 20 mm. The results of our tests of selected dental appliances indicate that their presence in the human organism is safe for patients undergoing magnetic resonance imaging procedures. The presence of artefacts can substantially influence the magnetic resonance imaging results.

  13. Laser beam melting 3D printing of Ti6Al4V based porous structured dental implants: fabrication, biocompatibility analysis and photoelastic study

    PubMed Central

    Yang, Fei; Chen, Chen; Zhou, QianRong; Gong, YiMing; Li, RuiXue; Li, ChiChi; Klämpfl, Florian; Freund, Sebastian; Wu, XingWen; Sun, Yang; Li, Xiang; Schmidt, Michael; Ma, Duan; Yu, YouCheng

    2017-01-01

    Fabricating Ti alloy based dental implants with defined porous scaffold structure is a promising strategy for improving the osteoinduction of implants. In this study, we use Laser Beam Melting (LBM) 3D printing technique to fabricate porous Ti6Al4V dental implant prototypes with three controlled pore sizes (200, 350 and 500 μm). The mechanical stress distribution in the surrounding bone tissue is characterized by photoelastography and associated finite element simulation. For in-vitro studies, experiments on implants’ biocompatibility and osteogenic capability are conducted to evaluate the cellular response correlated to the porous structure. As the preliminary results, porous structured implants show a lower stress-shielding to the surrounding bone at the implant neck and a more densed distribution at the bottom site compared to the reference implant. From the cell proliferation tests and the immunofluorescence images, 350 and 500 μm pore sized implants demonstrate a better biocompatibility in terms of cell growth, migration and adhesion. Osteogenic genes expression of the 350 μm group is significantly increased alone with the ALP activity test. All these suggest that a pore size of 350 μm provides an optimal provides an optimal potential for improving the mechanical shielding to the surrounding bones and osteoinduction of the implant itself. PMID:28350007

  14. Patient satisfaction 8-14 years after dental implant therapy - a questionnaire study.

    PubMed

    Adler, Lottie; Liedholm, Eva; Silvegren, Malin; Modin, Carolina; Buhlin, Kåre; Jansson, Leif

    2016-07-01

    The aim of this questionnaire study was to investigate patient satisfaction 8-14 years after dental implant therapy and complications influencing the degree of satisfaction. A questionnaire was sent by post to 587 patients at a specialist clinic of periodontology. The questionnaire consisted of 19 statements or questions such as the degree of satisfaction with the implants and knowledge of complications. In nine of the questions, respondents were asked to grade the extent of their agreement with a statement by selecting from fixed answers. Three of the questions were designed to be answered using a visual analog scale. In total, 400 individuals (81%) responded to the questionnaire. The mean time elapsed since implant installation was 10 years. A great majority (81%) experienced a high chewing comfort and was satisfied or sufficiently satisfied (94%) with the aesthetic aspects of their implant restorations, while 32% of the individuals had experienced problems with their implant reconstructions. The disadvantage that patients remarked on was the cost of the treatment. Those who had experienced problems with their implant reconstructions were also less satisfied with the treatment. A great majority of the patients expressed a high degree of satisfaction with their dental implants 8-14 years after the treatment. Patients were less satisfied if they had experience of problems with their implant reconstructions and in cases when the clinicians were unable to resolve their complications.

  15. Laser beam melting 3D printing of Ti6Al4V based porous structured dental implants: fabrication, biocompatibility analysis and photoelastic study

    NASA Astrophysics Data System (ADS)

    Yang, Fei; Chen, Chen; Zhou, Qianrong; Gong, Yiming; Li, Ruixue; Li, Chichi; Klämpfl, Florian; Freund, Sebastian; Wu, Xingwen; Sun, Yang; Li, Xiang; Schmidt, Michael; Ma, Duan; Yu, Youcheng

    2017-03-01

    Fabricating Ti alloy based dental implants with defined porous scaffold structure is a promising strategy for improving the osteoinduction of implants. In this study, we use Laser Beam Melting (LBM) 3D printing technique to fabricate porous Ti6Al4V dental implant prototypes with three controlled pore sizes (200, 350 and 500 μm). The mechanical stress distribution in the surrounding bone tissue is characterized by photoelastography and associated finite element simulation. For in-vitro studies, experiments on implants’ biocompatibility and osteogenic capability are conducted to evaluate the cellular response correlated to the porous structure. As the preliminary results, porous structured implants show a lower stress-shielding to the surrounding bone at the implant neck and a more densed distribution at the bottom site compared to the reference implant. From the cell proliferation tests and the immunofluorescence images, 350 and 500 μm pore sized implants demonstrate a better biocompatibility in terms of cell growth, migration and adhesion. Osteogenic genes expression of the 350 μm group is significantly increased alone with the ALP activity test. All these suggest that a pore size of 350 μm provides an optimal provides an optimal potential for improving the mechanical shielding to the surrounding bones and osteoinduction of the implant itself.

  16. Biocompatibility and anti-microbiological activity characterization of novel coatings for dental implants: A primer for non-biologists

    NASA Astrophysics Data System (ADS)

    Monsees, Thomas

    2016-08-01

    With regard to biocompatibility, the cardinal requirement for dental implants and other medical devices that are in long-term contact with tissue is that the material does not cause any adverse effect to the patient. To warrant stability and function of the implant, proper osseointegration is a further prerequisite. Cells interact with the implant surface as the interface between bulk material and biological tissue. Whereas structuring, deposition of a thin film or other modifications of the surface are crucial parameters in determining favorable adhesion of cells, corrosion of metal surfaces and release of ions can affect cell viability. Both parameters are usually tested using in vitro cytotoxicity and adhesion assays with bone or fibroblasts cells. For bioactive surface modifications, further tests should be considered for biocompatibility evaluation. Depending on the type of modification, this may include analysis of specific cell functions or the determination of antimicrobial activities. The latter is of special importance as bacteria and yeast present in the oral cavity can be introduced during the implantation process and this may lead to chronic infections and implant failure. An antimicrobial coating of the implant is a way to avoid that. This review describes the essential biocompatibility assays for evaluation of new implant materials required by ISO 10993 and also gives an overview on recent test methods for specific coatings of dental implants.

  17. A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology.

    PubMed

    Figliuzzi, M; Mangano, F; Mangano, C

    2012-07-01

    Direct laser metal forming (DLMF) is a new technique which allows solids with complex geometry to be produced by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model. For dental implants, the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer by layer, the desired object. Modern computed tomography (CT) acquisition and 3D image conversion, combined with the DLMF process, allows the fabrication of custom-made, root-analogue implants (RAI), perfect copies of the radicular units that need replacing. This report demonstrates the successful clinical use of a custom-made, root-analogue DLMF implant. CT images of the residual non-restorable root of a right maxillary premolar were acquired and modified with specific software into a 3D model. From this model, a custom-made, root-analogue, DLMF implant was fabricated. Immediately after tooth extraction, the root-analogue implant was placed in the extraction socket and restored with a single crown. At the 1-year follow-up examination, the custom-made implant showed almost perfect functional and aesthetic integration. The possibility of fabricating custom-made, root-analogue DLMF implants opens new interesting perspectives for immediate placement of dental implants. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. A comparative study of the effectiveness of early and delayed loading of short tissue-level dental implants with hydrophilic surfaces placed in the posterior section of the mandible-A preliminary study.

    PubMed

    Makowiecki, Arkadiusz; Botzenhart, Ute; Seeliger, Julia; Heinemann, Friedhelm; Biocev, Peter; Dominiak, Marzena

    2017-07-01

    The objective of the present study was to compare the primary and secondary stability of tissue-level short dental titanium implants with polished necks and hydrophilic surfaces of two different designs and manufacturers. The first implant system used (SPI ® ELEMENT RC INICELL titanium implants, Thommen Medical AG, Grenchen, Switzerland), allowed functional loading 6 weeks after its placement, whereas the second implant system (RN SLActiv ® tissue-level titanium implants, Straumann GmbH, Fribourg, Germany), was loaded after 15 weeks. The degree of primary and secondary stability was determined using an Osstell ISQ measuring device. Marginal bone loss (MBL) was evaluated radiographically 12 and 24 weeks after implantation and the Wachtel's healing index as well as the patient's satisfaction with the treatment was registered on a VAS scale. The intergroup comparison revealed significant differences in terms of primary stability as well as differences in MBL 3 months after the procedure, but no significant differences could be found after 6 months and for secondary stability. The primary stability was significantly higher for Thommen ® compared to Straumann ® implants. Insertion of short dental implants with a hydrophilic conditioned surface significantly shortens patient treatment time. Copyright © 2017 Elsevier GmbH. All rights reserved.

  19. Dosimetric evaluation of the effect of dental implants in head and neck radiotherapy.

    PubMed

    Ozen, Julide; Dirican, Bahar; Oysul, Kaan; Beyzadeoglu, Murat; Ucok, Ozlem; Beydemir, Bedri

    2005-06-01

    The aim of the study was to examine the dose enhancement from scattered radiation at bone-dental implant interfaces during simulated head and neck radiotherapy. Four cylindrical titanium dental implants with 3 different sizes and lengths were implanted into a human mandible in 4 different positions. Ionization measurements for 6 MV X, 25 MV X, and Co-60 gamma rays were done. Thermoluminescent dosimeter (TLD 100 ) chips were used to measure radiation dose enhancement due to the scattered electrons from titanium and electronic disequilibrium at the tissue-metal interface. The results showed that for Co-60, there is a 21% maximum increase in dose to alveolar mandibular bone at the close proximity to the titanium. For 6-MV x-rays the dose enhancement increase was almost the same or slightly lower than for Co-60, while for 25-MV high-energy x-rays, dose enhancement was lower than that of others. This increase in dose enhancement fell off rapidly and became insignificant at 2 mm from the interface. Total dose that may lead to osteoradionecrosis risk of the mandible is slightly but not significantly affected by the scattered dose of the dental implants of lower jaw in the radiation field exposed to 3 different radiation beams.

  20. Mixed zirconia calcium phosphate coatings for dental implants: tailoring coating stability and bioactivity potential.

    PubMed

    Pardun, Karoline; Treccani, Laura; Volkmann, Eike; Streckbein, Philipp; Heiss, Christian; Li Destri, Giovanni; Marletta, Giovanni; Rezwan, Kurosch

    2015-03-01

    Enhanced coating stability and adhesion are essential for long-term success of orthopedic and dental implants. In this study, the effect of coating composition on mechanical, physico-chemical and biological properties of coated zirconia specimens is investigated. Zirconia discs and dental screw implants are coated using the wet powder spraying (WPS) technique. The coatings are obtained by mixing yttria-stabilized zirconia (TZ) and hydroxyapatite (HA) in various ratios while a pure HA coating served as reference material. Scanning electron microscopy (SEM) and optical profilometer analysis confirm a similar coating morphology and roughness for all studied coatings, whereas the coating stability can be tailored with composition and is probed by insertion and dissections experiments in bovine bone with coated zirconia screw implants. An increasing content of calcium phosphate (CP) resulted in a decrease of mechanical and chemical stability, while the bioactivity increased in simulated body fluid (SBF). In vitro experiments with human osteoblast cells (HOB) revealed that the cells grew well on all samples but are affected by dissolution behavior of the studied coatings. This work demonstrates the overall good mechanical strength, the excellent interfacial bonding and the bioactivity potential of coatings with higher TZ contents, which provide a highly interesting coating for dental implants. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Sterilization of reusable implant components: a pilot study.

    PubMed

    Cain, J R; Mitchell, D L; Gillespie, J C

    2000-12-01

    The placement and restoration of dental implants require the use of numerous reusable instruments and components. The adequate sterilization of reusable instruments and components is essential to prevent cross contamination between patients. Sterilization usually is accomplished with single-use sterilization envelopes. A reusable sterilization vehicle would reduce costs as well as the waste generated in patient care. This study was designed to determine the efficacy of a 10-cc Pyrex test tube as a sterilization vehicle for reusable dental implant instruments and components. In this study, a reusable dental implant component was placed in a Pyrex test tube, along with a biologic test strip. A control biologic test strip was kept for each test tube. The test tube was closed with a cotton roll folded in half and placed in the opening. Twenty test tubes were prepared. five sets of 4 test tubes were placed in an autoclave in different locations with varying orientations. The autoclave completed a standard sterilization cycle. The biological monitoring service indicated that the biologic test strips in 100% of the test tubes were sterile, whereas the control strips were 100% nonsterile. A Pyrex test tube sealed with a cotton roll can serve as a sterilization vehicle for reusable dental implant instruments and components.

  2. Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis.

    PubMed

    Schwindling, Franz Sebastian; Schwindling, Franz-Peter

    2016-07-01

    The purpose of this study was to assess the survival of mini dental implants (MDI) and to measure prosthetic maintenance needs in a dental practice-based setting. Patients with mandibular removable dentures were provided with MDI to improve denture retention. Complications and maintenance were analyzed by use of patient records and evaluated with Kaplan-Meier curves and the log rank test at a significance level of 0.05. Ninety-nine MDI were placed in 25 patients (mean age: 72 years). Two MDI fractured during placement and eight implants failed during the first weeks. No more implants were lost for up to seven years, resulting in 92% survival. Implant survival differed significantly depending on whether the maxilla was provided with complete dentures (94.9%) or with partial dentures (81%). All prostheses were in use at the time of data extraction. Denture base fractures were observed in six cases, an incidence of fractures of 24%. Some minor intervention was necessary: one resin tooth fractured, retention rings were changed in five cases, and repeated relining was required for 16% of the dentures. After mid-term observation, survival of MDI was good. However, the incidence of denture base fractures and of minor prosthetic complications should not be under-estimated. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Inhibition of adherence of C. albicans to dental implants and cover screws by Cymbopogon nardus essential oil and citronellal.

    PubMed

    Trindade, Leonardo Antunes; de Araújo Oliveira, Julyana; de Castro, Ricardo Dias; de Oliveira Lima, Edeltrudes

    2015-12-01

    This study investigated the biological activity of the essential oil from Cymbopogon nardus and of the phytoconstituent citronellal on Candida strains as to the inhibition of adherence to dental implants and cover screws. The essential oil was analyzed by gas chromatography coupled to mass spectrometry (GC-MS) and had its MIC and MFC determined against 12 strains of Candida. Then, tests of inhibition of adherence to the dental implants and cover screws were carried out using the MIC of the substances, followed by scanning electron microscopy analysis. Nystatin and chlorhexidine were used as positive controls, and experiments were performed in triplicate. The analysis by GC-MS of the essential oil identified citronellal as the major compound. The MICs of the essential oil, citronellal, chlorhexidine, and nystatin--able to inhibit 100 % of the strains--were found to be 64, 512, 64, and 32 μg/ml, respectively. The essential oil significantly inhibited the adherence of Candida albicans to the dental implants and cover screws (p < 0.001). Citronellal inhibited yeast adherence only to the dental implants (p < 0.001), and no significant results were found for the cover screws (p > 0.05) compared to the growth control. The essential oil and citronellal have proven antifungal activity and are able to inhibit the in vitro adherence of C. albicans. There has been a search for alternative natural product-containing formulations that should be effective in inhibiting adherence of yeasts to the surfaces of materials and also able to treat oral fungal infections. Further trials could make these products an alternative to chemical removal of peri-implant biofilm.

  4. Consensus Report of the XI Congress of the Spanish Society of Odontology for the Handicapped and Special Patients

    PubMed Central

    Cabrerizo-Merino, Carmen; Cutando-Soriano, Antonio; Giménez-Prats, María J.; Silvestre-Donat, Farncisco J.; Tomás-Carmona, Inmaculada

    2014-01-01

    This article summarizes the findings of consensus of the XI congress of the SEOEME. All of these conclusions are referring to the review articles responsible to the general rapporteurs in order to bringing up to date knowledge with regard to the use of implants in patients medically compromised and with special needs and, in the dental management of autism and cerebral palsy, in the dental treatment of patients with genetic and adquired haematological disorders, the dental implications of cardiovascular disease and hospital dentistry. Key words:Autism, cardiovascular diseases, cerebral palsy, dental implants, disabled patients, haematological disorders, hospital dentistry. PMID:24608224

  5. Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

    PubMed

    Duan, Yuanyuan; Gonzalez, Jorge A; Kulkarni, Pratim A; Nagy, William W; Griggs, Jason A

    2018-06-16

    To validate the fatigue lifetime of a reduced-diameter dental implant system predicted by three-dimensional finite element analysis (FEA) by testing physical implant specimens using an accelerated lifetime testing (ALT) strategy with the apparatus specified by ISO 14801. A commercially-available reduced-diameter titanium dental implant system (Straumann Standard Plus NN) was digitized using a micro-CT scanner. Axial slices were processed using an interactive medical image processing software (Mimics) to create 3D models. FEA analysis was performed in ABAQUS, and fatigue lifetime was predicted using fe-safe ® software. The same implant specimens (n=15) were tested at a frequency of 2Hz on load frames using apparatus specified by ISO 14801 and ALT. Multiple step-stress load profiles with various aggressiveness were used to improve testing efficiency. Fatigue lifetime statistics of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined using SEM with fractographic technique to determine the failure mode. FEA predicted lifetime was within the 95% confidence interval of lifetime estimated by experimental results, which suggested that FEA prediction was accurate for this implant system. The highest probability of failure was located at the root of the implant body screw thread adjacent to the simulated bone level, which also agreed with the failure origin in physical specimens. Fatigue lifetime predictions based on finite element modeling could yield similar results in lieu of physical testing, allowing the use of virtual testing in the early stages of future research projects on implant fatigue. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  6. An ex vivo model in human femoral heads for histopathological study and resonance frequency analysis of dental implant primary stability.

    PubMed

    Hernández-Cortés, Pedro; Monje, Alberto; Galindo-Moreno, Pablo; Catena, Andrés; Ortega-Oller, Inmaculada; Salas-Pérez, José; Mesa, Francisco; Gómez-Sánchez, Rafael; Aguilar, Mariano; Aguilar, David; O'Valle, Francisco

    2014-01-01

    This study was designed to explore relationships of resonance frequency analysis (RFA)-assessed implant stability (ISQ values) with bone morphometric parameters and bone quality in an ex vivo model of dental implants placed in human femoral heads and to evaluate the usefulness of this model for dental implant studies. This ex vivo study included femoral heads from 17 patients undergoing surgery for femoral neck fracture due to osteoporosis (OP) (n = 7) or for total prosthesis joint replacement due to severe hip osteoarthrosis (OA) (n = 10). Sixty 4.5 × 13 mm Dentsply Astra implants were placed, followed by RFA. CD44 immunohistochemical analysis for osteocytes was also carried out. As expected, the analysis yielded significant effects of femoral head type (OA versus OA) (P < 0.001), but not of the implants (P = 0.455) or of the interaction of the two factors (P = 0.848). Bonferroni post hoc comparisons showed a lower mean ISQ for implants in decalcified (50.33 ± 2.92) heads than in fresh (66.93 ± 1.10) or fixated (70.77 ± 1.32) heads (both P < 0.001). The ISQ score (fresh) was significantly higher for those in OA (73.52 ± 1.92) versus OP (67.13 ± 1.09) heads. However, mixed linear analysis showed no significant association between ISQ scores and morphologic or histomorphometric results (P > 0.5 in all cases), and no significant differences in ISQ values were found as a function of the length or area of the cortical layer (both P > 0.08). Although RFA-determined ISQ values are not correlated with morphometric parameters, they can discriminate bone quality (OP versus OA). This ex vivo model is useful for dental implant studies.

  7. Improved Dental Implant Drill Durability and Performance Using Heat and Wear Resistant Protective Coatings.

    PubMed

    Er, Nilay; Alkan, Alper; Ilday, Serim; Bengu, Erman

    2018-06-01

    The dental implant drilling procedure is an essential step for implant surgery, and frictional heat in bone during drilling is a key factor affecting the success of an implant. The aim of this study was to increase the dental implant drill lifetime and performance by using heat- and wear-resistant protective coatings to decrease the alveolar bone temperature caused by the dental implant drilling procedure. Commercially obtained stainless steel drills were coated with titanium aluminum nitride, diamond-like carbon, titanium boron nitride, and boron nitride coatings via magnetron-sputter deposition. Drilling was performed on bovine femoral cortical bone under the conditions mimicking clinical practice. Tests were performed under water-assisted cooling and under the conditions when no cooling was applied. Coated drill performances and durabilities were compared with those of three commonly used commercial drills with surfaces made from zirconia, black diamond. and stainless steel. Protective coatings with boron nitride, titanium boron nitride, and diamond-like carbon have significantly improved drill performance and durability. In particular, boron nitride-coated drills have performed within safe bone temperature limits for 50 drillings even when no cooling is applied. Titanium aluminium nitride coated drills did not show any improvement over commercially obtained stainless steel drills. Surface modification using heat- and wear-resistant coatings is an easy and highly effective way to improve implant drill performance and durability, which can improve the surgical procedure and the postsurgical healing period. The noteworthy success of different types of coatings is novel and likely to be applicable to various other medical systems.

  8. Torsional resonance frequency analysis: a novel method for assessment of dental implant stability.

    PubMed

    Tang, Yu-Long; Li, Bing; Jin, Wei; Li, De-Hua

    2015-06-01

    To establish and experimentally validate a novel resonance frequency analysis (RFA) method for measurement of dental implant stability by analyzing torsional resonance frequency (TRF). A numerical study and in vitro measurements were performed to evaluate the feasibility and reliability of the method of torsional RFA (T-RFA) using a T-shaped bilateral cantilever beam transducer. The sensitivity of this method was assessed by measuring the TRFs of dental implants with 8 sizes of T-shaped transducers during polymerization, which simulated the process of bone healing around an implant. The TRFs of the test implants detected using this new method and the bending resonance frequencies (BRFs) measured by Osstell(®) ISQ were compared. TRFs and BRFs on implant models in polymethyl methacrylate (PMMA) blocks with three exposure heights were also measured to assess the specificity of this method. Finite element analysis showed two bending modes (5333 and 6008 Hz) following a torsional mode (8992 Hz) in the lower rank frequency. During in vitro measurements, a bending formant (mean 6075 Hz) and a torsional formant (mean 10225 Hz) appeared, which were verified by multipoint measurement with invariable excitation frequency in the laboratory. In the self-curing resin experiments, the average growth rate at all time points of TRFs using the new method with Transducer II was 2.36% and that of BRFs using Osstell(®) ISQ was 1.97%. In the implant exposure height tests, the mean declined rate of TRFs was 2.06% and that of BRFs using Osstell(®) ISQ was 12.34%. A novel method for assessment of implant stability through TRF was established using a T-shape transducer, which showed high reliability and sensibility. The method alleviated the effects of implant exposure height on the measurements compared with Osstell(®) ISQ. The application of T-RFA represents another way in the investigation of dental implant osseointegration. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Cooling profile following prosthetic preparation of 1-piece dental implants.

    PubMed

    Cohen, Omer; Gabay, Eran; Machtei, Eli E

    2010-01-01

    The aim of this study was to evaluate the effect of water irrigation on heat dissipation kinetics following abutment preparation of 1-piece dental implants. UNO 1-piece dental implants were mounted on Plexiglas apparatus clamping the implant at the collar. T-type thermocouple was attached to the first thread of the implant and recorded thermal changes at 100 millisecond intervals. Implants were prepared using highspeed dental turbine at 400,000 RPM with a coarse diamond bur. Once temperature reached 47 degrees C, abutment preparation was discontinued. Thirty implants were divided into 2 groups. Group A: Passive cooling without water irrigation. Group B: Cooling with turbine's water spray adjacent to the implant (30 mL/min). The following parameters were measured: T47 (time from peak temperature to 47 degrees C), T50%, T75% (time until the temperature amplitude decayed by 50% and 75%, respectively), dTemp50%/dt decay, and dTemp75%/dt decay (cooling rate measured at 50% and 75% of amplitude decay, respectively). Water spray irrigation significantly reduced T47 (1.37+/-0.29 seconds vs 19.97+/-3.06 seconds, P<0.0001), T50% (3.04+/-0.34 seconds vs 27.37+/-2.56 seconds, P<0.0001), and T75% (5.71+/-0.57 seconds vs 57.61+/-5.47 seconds, P<0.0001). Water spray irrigation also increased cooling capacity ninefold: dTemp50%/dt decay (4.14+/-0.61 degrees C/s vs 0.48+/-0.06 degrees C/s, P<0.0001), and dTemp50%/dt decay (1.70+/-0.29 degrees C/s vs 0.19+/-0.03 degrees C/s, P<0.0001). The continuous use of water spray adjacent to the abutment following the cessation of implant preparation might prove beneficial for rapid cooling of the implant.

  10. Immediate provisionalization of dental implants placed in healed alveolar ridges and extraction sockets: a 5-year prospective evaluation.

    PubMed

    Cooper, Lyndon F; Reside, Glenn J; Raes, Filiep; Garriga, Joan Soliva; Tarrida, Luis Giner; Wiltfang, Jörg; Kern, Matthias; De Bruyn, Hugo

    2014-01-01

    This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 ± 0.63 mm and 0.38 ± 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 ± 1.34 mm vs 0.19 ± 0.79 mm). After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.

  11. Periodontal and periimplant maintenance: a critical factor in long-term treatment success.

    PubMed

    Shumaker, Nicholas D; Metcalf, Brett T; Toscano, Nicholas T; Holtzclaw, Dan J

    2009-09-01

    Periodontal maintenance (PM) is a critical factor in the long-term success of both periodontal and dental implant therapy. Studies have shown both modern periodontal and dental implant therapies are effective in maintaining natural teeth and replacing lost teeth, respectively. However, without a regular program of clinical reevaluation, plaque control, oral hygiene instruction, and reassessment of biomechanical factors, the benefits of treatment often are lost and inflammatory disease in the form of recurrent periodontitis or periimplantitis may result. This article reviews the goals, types, and appropriate frequency of PM in periodontal and dental implant therapy, as well as the incidence and etiology of periimplant disease and strategies for management when recurrent disease develops during the maintenance phase of treatment.

  12. The effects of implant angulation on the resonance frequency of a dental implant.

    PubMed

    Harirforoush, R; Arzanpour, S; Chehroudi, B

    2014-08-01

    Dental implants are ideally placed in an orientation that allows vertical transfer of occlusal forces along their long axis. Nevertheless, optimal situations for implant placement are seldom encountered resulting in implants placement in angulated positions, which may affect their long-term success. The resonance frequency (RF) is an objective tool used to monitor stability of the implant tissue integration; however, little is known of the effect of the implant orientation in bone on the RF and its potential significance. The purpose of this research was to determine the relation between the dental implant orientation and the corresponding RF of implant. Three-dimensional (3D) modelling software was used to construct a 3D model of a pig mandible from computed tomography (CT) images. The RF of the implant was analysed using finite element (FE) modal analysis in software ANSYS (v.12). In addition, a cubical model was also developed in MIMICS to investigate the parameters affecting the relationship between RF and implant orientation in a simplified environment. The orientation angle was increased from 0 to 10 degrees in 1 degree increments and the resulting RF was analysed using correlation analysis and one-way ANOVA. Our analysis illustrated that the RF fluctuation following altering implant orientation was strongly correlated (r=0.97) with the contacting cortical to cancellous bone ratio (CCBR) at the implant interface. The most extreme RF change (from 9.81kHz to 10.07kHz) occurred when the implant was moved 0.5mm in positive z-direction, which resulted in the maximum change of CCBR from 52.9 to 54.8. Copyright © 2014. Published by Elsevier Ltd.

  13. 78 FR 27971 - Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ...] Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Dental Products Panel of the Medical Devices Advisory Committee. General Function of the Committee: To... regulatory classification for dental devices known as Endosseous Dental Implants (Blade-form), one of the...

  14. A 5-year retrospective case series evaluating Brånemark Integration BioHelix (™) dental implants placed in a private practice by a specialist.

    PubMed

    Thomsson, Mats; Larsson Wexell, Cecilia

    2013-09-01

    To evaluate, in a case series, survival rate and complications of Brånemark Integration BioHelix(™) dental implants, placed according to conventional procedures in patients treated consecutively in a Swedish specialist private practice after 5 years. Eighty-three consecutively-treated patients received 89 final fixed prostheses supported by 310 implants placed according to 'conventional' procedure, i.e. no implants shorter than 10 mm, no immediate post-extraction implants and no bone-grafting procedures. In 70 patients, implants were left to heal submerged, whereas 13 patients were treated according to the one-stage protocol. All implants were incorporated in a prosthetic restoration. Probing was only performed when clinical signs of inflammation were present and this was then evaluated further with intra-oral radiographic examination. Outcome measures were implant survival and prosthetic complications. Five years after implant placement, two fixtures were removed because of loosening. One fixture was lost after 12 months in the lower jaw in one patient and one fixture was lost in the upper jaw in another patient after 3 years, both inserted using the two-stage technique. No other prosthetic complications occurred, giving a 99.3% cumulative survival rate. Brånemark Integration BioHelix(™) dental implants placed according to one- or two-stage procedures in patients in a private practice produced excellent 5-year results. Randomized clinical trials with suitable controls are suggested to confirm these results.

  15. Impression of multiple implants using photogrammetry: description of technique and case presentation.

    PubMed

    Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz; Peñarrocha, María

    2014-07-01

    To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions - angles and distances - of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient's mouth using the Sheffield test and the screw resistance test. Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient.

  16. Clinical evidence on titanium-zirconium dental implants: a systematic review and meta-analysis.

    PubMed

    Altuna, P; Lucas-Taulé, E; Gargallo-Albiol, J; Figueras-Álvarez, O; Hernández-Alfaro, F; Nart, J

    2016-07-01

    The use of titanium implants is well documented and they have high survival and success rates. However, when used as reduced-diameter implants, the risk of fracture is increased. Narrow diameter implants (NDIs) of titanium-zirconium (Ti-Zr) alloy have recently been developed (Roxolid; Institut Straumann AG). Ti-Zr alloys (two highly biocompatible materials) demonstrate higher tensile strength than commercially pure titanium. The aim of this systematic review was to summarize the existing clinical evidence on dental NDIs made from Ti-Zr. A systematic literature search was performed using the Medline database to find relevant articles on clinical studies published in the English language up to December 2014. Nine clinical studies using Ti-Zr implants were identified. Overall, 607 patients received 922 implants. The mean marginal bone loss was 0.36±0.06mm after 1 year and 0.41±0.09mm after 2 years. The follow-up period ranged from 3 to 36 months. Mean survival and success rates were 98.4% and 97.8% at 1 year after implant placement and 97.7% and 97.3% at 2 years. Narrow diameter Ti-Zr dental implants show survival and success rates comparable to regular diameter titanium implants (>95%) in the short term. Long-term follow-up clinical data are needed to confirm the excellent clinical performance of these implants. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Controlled release of metronidazole from composite poly-ε-caprolactone/alginate (PCL/alginate) rings for dental implants.

    PubMed

    Lan, Shih-Feng; Kehinde, Timilehin; Zhang, Xiangming; Khajotia, Sharukh; Schmidtke, David W; Starly, Binil

    2013-06-01

    Dental implants provide support for dental crowns and bridges by serving as abutments for the replacement of missing teeth. To prevent bacterial accumulation and growth at the site of implantation, solutions such as systemic antibiotics and localized delivery of bactericidal agents are often employed. The objective of this study was to demonstrate a novel method of controlled localized delivery of antibacterial agents to an implant site using a biodegradable custom fabricated ring. The study involved incorporating a model antibacterial agent (metronidazole) into custom designed poly-ε-caprolactone/alginate (PCL/alginate) composite rings to produce the intended controlled release profile. The rings can be designed to fit around the body of any root form dental implants of various diameters, shapes and sizes. In vitro release studies indicate that pure (100%) alginate rings exhibited an expected burst release of metronidazole in the first few hours, whereas Alginate/PCL composite rings produced a medium burst release followed by a sustained release for a period greater than 4 weeks. By varying the PCL/alginate weight ratios, we have shown that we can control the amount of antibacterial agents released to provide the minimal inhibitory concentration (MIC) needed for adequate protection. The fabricated composite rings have achieved a 50% antibacterial agent release profile over the first 48 h and the remaining amount slowly released over the remainder of the study period. The PCL/alginate agent release characteristic fits the Ritger-Peppas model indicating a diffusion-based mechanism during the 30-day study period. The developed system demonstrates a controllable drug release profile and the potential for the ring to inhibit bacterial biofilm growth for the prevention of diseases such as peri-implantitis resulting from bacterial infection at the implant site. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Subgingival microbiome in patients with healthy and ailing dental implants

    PubMed Central

    Zheng, Hui; Xu, Lixin; Wang, Zicheng; Li, Lianshuo; Zhang, Jieni; Zhang, Qian; Chen, Ting; Lin, Jiuxiang; Chen, Feng

    2015-01-01

    Dental implants are commonly used to replace missing teeth. However, the dysbiotic polymicrobial communities of peri-implant sites are responsible for peri-implant diseases, such as peri-implant mucositis and peri-implantitis. In this study, we analyzed the microbial characteristics of oral plaque from peri-implant pockets or sulci of healthy implants (n = 10), peri-implant mucositis (n = 8) and peri-implantitis (n = 6) sites using pyrosequencing of the 16S rRNA gene. An increase in microbial diversity was observed in subgingival sites of ailing implants, compared with healthy implants. Microbial co-occurrence analysis revealed that periodontal pathogens, such as Porphyromonas gingivalis, Tannerella forsythia, and Prevotella intermedia, were clustered into modules in the peri-implant mucositis network. Putative pathogens associated with peri-implantitis were present at a moderate relative abundance in peri-implant mucositis, suggesting that peri-implant mucositis an important early transitional phase during the development of peri-implantitis. Furthermore, the relative abundance of Eubacterium was increased at peri-implantitis locations, and co-occurrence analysis revealed that Eubacterium minutum was correlated with Prevotella intermedia in peri-implantitis sites, which suggests the association of Eubacterium with peri-implantitis. This study indicates that periodontal pathogens may play important roles in the shifting of healthy implant status to peri-implant disease. PMID:26077225

  19. Antimicrobial surfaces for craniofacial implants: state of the art.

    PubMed

    Actis, Lisa; Gaviria, Laura; Guda, Teja; Ong, Joo L

    2013-04-01

    In an attempt to regain function and aesthetics in the craniofacial region, different biomaterials, including titanium, hydroxyapatite, biodegradable polymers and composites, have been widely used as a result of the loss of craniofacial bone. Although these materials presented favorable success rates, osseointegration and antibacterial properties are often hard to achieve. Although bone-implant interactions are highly dependent on the implant's surface characteristics, infections following traumatic craniofacial injuries are common. As such, poor osseointegration and infections are two of the many causes of implant failure. Further, as increasingly complex dental repairs are attempted, the likelihood of infection in these implants has also been on the rise. For these reasons, the treatment of craniofacial bone defects and dental repairs for long-term success remains a challenge. Various approaches to reduce the rate of infection and improve osseointegration have been investigated. Furthermore, recent and planned tissue engineering developments are aimed at improving the implants' physical and biological properties by improving their surfaces in order to develop craniofacial bone substitutes that will restore, maintain and improve tissue function. In this review, the commonly used biomaterials for craniofacial bone restoration and dental repair, as well as surface modification techniques, antibacterial surfaces and coatings are discussed.

  20. Changes in passive tactile sensibility associated with dental implants following their placement.

    PubMed

    El-Sheikh, Ali M; Hobkirk, John A; Howell, Peter G T; Gilthorpe, Mark S

    2003-01-01

    This study investigated the changes that might occur in passive tactile sensibility during a period of 3 months following Implant placement in a group of edentulous subjects treated with dental implants. The effect of changing the velocity of force application on passive tactile sensibility was also investigated. Five edentulous subjects who had been treated (as a part of an immediate loading study) with 2 or more Nobel Biocare dental implants in the anterior mandible were studied. Pushing forces were applied directly and perpendicular to the long axes of the abutments until the subjects felt the first sensation of pressure, using a computer-controlled, custom-made device. The force was measured with an integral transducer. The applied force had a ramped staircase pattern, which was used at 2 different tip velocities. The measurements were taken on 4 occasions: 1, 2, 4, and 12 weeks after fitting the abutments. Statistical analysis, using multilevel modeling, demonstrated that there was a significant decrease In the tactile threshold over successive weeks following implant placement. It also demonstrated that high velocity exhibited a higher threshold than low velocity. It could be concluded that there was a significant increase In passive tactile sensibility during the healing phase following implant placement.

  1. Interest in dental implantology and preferences for implant therapy: a survey of Victorian dentists.

    PubMed

    Cheung, M C; Kao, Plh; Lee, N; Sivathasan, D; Vong, C W; Zhu, J; Polster, A; Darby, I

    2016-12-01

    The purpose of this study was to gauge dentists' interest, knowledge and training in implantology, and to compare their treatment preferences with current literature. Subsequently, this information may be used to evaluate implantology education pathways. A cross-sectional postal survey of 600 randomly selected dentists registered with the Dental Practice Board of Victoria was conducted. Respondents were asked about background, interest and training in implantology, and implant treatment preferences. Results were analysed according to primary practice location, decade of graduation and attendance at continuing professional development (CPD) programmes. One hundred and seventy-six questionnaires were included for analysis. In general, dentists rate their implant knowledge, interest and enjoyment in restoring implants favourably. No differences were found between city and country practitioners, and different graduation decades. The level of CPD significantly influenced treatment preferences. Practitioners were generally unwilling to treat patients taking bisphosphonates, or to perform grafting procedures. Most dentists provide common services to treat peri-implant conditions. Direct-to-fixture is the most popular fixture-abutment connection. Overall, there is a high level of implant knowledge corresponding to current evidence in the literature. Level of CPD attendance is the most important factor in dentists' willingness to provide more implant therapy options. © 2016 Australian Dental Association.

  2. Mechanical design, analysis, and laboratory testing of a dental implant with axial flexibility similar to natural tooth with periodontal ligament.

    PubMed

    Pektaş, Ömer; Tönük, Ergin

    2014-11-01

    At the interface between the jawbone and the roots of natural teeth, a thin, elastic, shock-absorbing tissue, called the periodontal ligament, forms a cushion which provides certain flexibility under mechanical loading. The dental restorations supported by implants, however, involve comparatively rigid connections to the jawbone. This causes overloading of the implant while bearing functional loading together with neighboring natural teeth, which leads to high stresses within the implant system and in the jawbone. A dental implant, with resilient components in the upper structure (abutment) in order to mimic the mechanical behavior of the periodontal ligament in the axial direction, was designed, analyzed in silico, and produced for mechanical testing. The aims of the design were avoiding high levels of stress, loosening of the abutment connection screw, and soft tissue irritations. The finite element analysis of the designed implant revealed that the elastic abutment yielded a similar axial mobility with the natural tooth while keeping stress in the implant at safe levels. The in vitro mechanical testing of the prototype resulted in similar axial mobility predicted by the analysis and as that of a typical natural tooth. The abutment screw did not loosen under repeated loading and there was no static or fatigue failure. © IMechE 2014.

  3. Maxillary overdentures supported by anteriorly or posteriorly placed implants opposed by a natural dentition in the mandible: a 1-year prospective case series study.

    PubMed

    Slot, Wim; Raghoebar, Gerry M; Vissink, Arjan; Meijer, Henny J A

    2014-02-01

    For maxillary overdenture therapy, treatment guidelines are missing. There is a need for longitudinal studies. The purpose of this 1-year prospective case series study was to assess the treatment outcome of maxillary overdentures supported by six dental implants opposed by natural antagonistic teeth in the mandible. Fifty patients were treated with a maxillary overdenture supported by six dental implants, either placed in the anterior region (n = 25 patients) or in the posterior region (n = 25 patients). Items of evaluation were the following: survival of implants, condition of hard and soft peri-implant tissues, and patients' satisfaction. One-year implant survival rate was 98% in the anterior group and 99.3% in the posterior group. Mean radiographic bone loss in the anterior and posterior groups after 1 year of loading was 0.22 and 0.50 mm, respectively. Mean scores for plaque, calculus, gingiva, bleeding, and pocket probing depth were low, and patients' satisfaction was high, with no differences between the groups. Six dental implants placed in either the anterior region or the posterior region of the edentulous maxilla, connected with a bar, and opposed by antagonistic teeth in the mandible supply a proper base for the support of an overdenture. © 2012 Wiley Periodicals, Inc.

  4. Fatigue failure of dental implants in simulated intraoral media.

    PubMed

    Shemtov-Yona, K; Rittel, D

    2016-09-01

    Metallic dental implants are exposed to various intraoral environments and repetitive loads during service. Relatively few studies have systematically addressed the potential influence of the environment on the mechanical integrity of the implants, which is therefore the subject of this study. Four media (groups) were selected for room temperature testing, namely dry air, saliva substitute, same with 250ppm of fluoride, and saline solution (0.9%). Monolithic Ti-6Al-4V implants were loaded until fracture, using random spectrum loading. The study reveals that the only aggressive medium of all is the saline solution, as it shortens significantly the spectrum fatigue life of the implants. The quantitative scanning electron fractographic analysis indicates that all the tested implants grew fatigue cracks of similar lengths prior to catastrophic fracture. However, the average crack growth rate in the saline medium was found to largely exceed that in other media, suggesting a decreased fracture toughness. The notion of a characteristic timescale for environmental degradation was proposed to explain the results of our spectrum tests that blend randomly low and high cycle fatigue. Random spectrum fatigue testing is powerful technique to assess and compare the mechanical performance of dental implants for various designs and/or environments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. New operational techniques of implantation of biomaterials and titanium implants in the jaw with the atrophy of the bone and soft tissues

    NASA Astrophysics Data System (ADS)

    Nikityuk, D. B.; Urakov, A. L.; Reshetnikov, A. P.; Kopylov, M. V.; Baimurzin, D. Yu.

    2015-11-01

    The research into dynamics of quality of clinical use in 2003 - 2012 of autologous and xenogeneic biomaterials at dental transplantation and implantation among 1,100 of adult patients was made. The analysis results show that at autologous bone transplantation implant survival is observed only in 72% of cases, and the "necessary" result of bone repair occurred only in 6 - 9 months. Transplantation of biomaterials of OsteoBiol® (materials "mp3", "Genos" and "Evolution") provided engraftment and bone regeneration in 100 % of cases and allowed the use of dental implantation immediately after transplantation even in case of reduction in the patient's alveolar crest down to 2.0 mm. Replace Select implants of Nobel Biocare® were used at plantation. In order to exclude Schneiderian membrane's perforation lighting of Highmore's sinus with the cold blue-violet light from inside at sinus elevation is recommended as well as deepening of dental instruments into the bone only until the blue-violet light appears under them. To exclude deficiency of soft tissue under the cervical part of the ceramic crown application of special anti-fissure technology involving biomaterial flap dissection and its laying around the implant is suggested.

  6. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    PubMed

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  7. Heterotopic bone formation around sintered porous-surfaced Ti-6Al-4V implants coated with native bone morphogenetic proteins.

    PubMed

    Simon, Ziv; Deporter, Douglas A; Pilliar, Robert M; Clokie, Cameron M

    2006-09-01

    Coating endosseous dental implants with growth factors such as bone morphogenetic proteins (BMPs) may be one way to accelerate and/or enhance the quality of osseointegration. The purpose of this study was to investigate in the murine muscle pouch model whether sintered porous-surfaced titanium alloy implants coated with BMPs would lead to heterotopic bone formation around and within the implant surface geometry. Porous-surfaced dental implants were coated with partially purified native human BMPs, with or without a carrier of Poloxamer 407 (BASF Corp., Parsippany, NJ), placed in gelatin capsules and implanted into the hindquarter muscles of mice. Mice were euthanized after 28 days. Sections of retrieved specimens were subsequently prepared for morphometric analysis of bone formation using backscatter electron microscopic images. Human BMPs, either with or without the carrier of Poloxamer 407, led to bone formation within and outside of the sintered porous implant surface. When the sintered implant surface region was subdivided into inner and outer halves, similar levels of bone ingrowth and contact were seen in the 2 halves. Evidence of bone formation to the depth of the solid implant core (i.e., the deepest level possible) also was seen. Sintered porous-surfaced dental implants can be used as substrate for partially purified BMPs in the murine muscle pouch model. With the addition of these osteoinductive factors, the porous implant surface supported bone formation within the surface porosity provided, in some instances, all the way to the solid implant core. The addition of growth factors to a sintered porous surface may be an efficient method for altering locally the healing sequence and quality of bone associated with osseointegration of bone-interfacing implants.

  8. Effect of dental cements on peri-implant microbial community: comparison of the microbial communities inhabiting the peri-implant tissue when using different luting cements.

    PubMed

    Korsch, Michael; Marten, Silke-Mareike; Dötsch, Andreas; Jáuregui, Ruy; Pieper, Dietmar H; Obst, Ursula

    2016-12-01

    Cementing dental restorations on implants poses the risk of undetected excess cement. Such cement remnants may favor the development of inflammation in the peri-implant tissue. The effect of excess cement on the bacterial community is not yet known. The aim of this study was to analyze the effect of two different dental cements on the composition of the microbial peri-implant community. In a cohort of 38 patients, samples of the peri-implant tissue were taken with paper points from one implant per patient. In 15 patients, the suprastructure had been cemented with a zinc oxide-eugenol cement (Temp Bond, TB) and in 23 patients with a methacrylate cement (Premier Implant Cement, PIC). The excess cement found as well as suppuration was documented. Subgingival samples of all patients were analyzed for taxonomic composition by means of 16S amplicon sequencing. None of the TB-cemented implants had excess cement or suppuration. In 14 (61%) of the PIC, excess cement was found. Suppuration was detected in 33% of the PIC implants without excess cement and in 100% of the PIC implants with excess cement. The taxonomic analysis of the microbial samples revealed an accumulation of oral pathogens in the PIC patients independent of the presence of excess cement. Significantly fewer oral pathogens occurred in patients with TB compared to patients with PIC. Compared with TB, PIC favors the development of suppuration and the growth of periodontal pathogens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Long-Term Survival of Dental Implants with Different Prosthetic Loading Times in Healthy Patients: A 5-Year Retrospective Clinical Study.

    PubMed

    Muelas-Jiménez, M Isabel; Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco J; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel

    2017-02-01

    To compare survival rates among dental implants restored with immediate, early, and conventional loading protocols, also comparing between maxillary and mandibular implants, and to evaluate the influence of implant length and diameter and the type of prosthesis on treatment outcomes. This retrospective cohort study initially included all 52 patients receiving dental implants between July 2006 and February 2008 at a private oral surgery clinic in Granada (Southern Spain). Clinical and radiographic examinations were performed, including periapical or panoramic radiographs, and incidences during completion of the restoration were recorded at 1 week, 3 months, 6 months, and at 1, 2, 3, 4, and 5 years. After a 5-year follow-up, 1 patient had died, 3 were lost to follow-up, and 6 required grafting before implant placement; therefore, the final study sample comprised 42 patients with 164 implants. Variables associated with the survival/failure of the restoration were: number of implants (higher failure rate with fewer implants), bone type (higher failure rate in type III or IV bone), and type of prosthesis (higher failure rate with single crowns). No significant association was found in univariate or multivariate analyses between survival rate and the loading protocol, implant length or diameter, or maxillary/mandibular location. Immediate occlusal loading, immediate provisionalization without occlusal loading, and early loading are viable treatment options with similar survival rates to those obtained with conventional loading. Bone quality and number of implants per patient were the most influential factors. © 2015 by the American College of Prosthodontists.

  10. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

    PubMed

    Rack, A; Rack, T; Stiller, M; Riesemeier, H; Zabler, S; Nelson, K

    2010-03-01

    Micro-gap formation at the implant-abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites.

  11. Finite element analysis of dental implant loading on atrophic and non-atrophic cancellous and cortical mandibular bone - a feasibility study.

    PubMed

    Marcián, Petr; Borák, Libor; Valášek, Jiří; Kaiser, Jozef; Florian, Zdeněk; Wolff, Jan

    2014-12-18

    The first aim of this study was to assess displacements and micro-strain induced on different grades of atrophic cortical and trabecular mandibular bone by axially loaded dental implants using finite element analysis (FEA). The second aim was to assess the micro-strain induced by different implant geometries and the levels of bone-to-implant contact (BIC) on the surrounding bone. Six mandibular bone segments demonstrating different grades of mandibular bone atrophy and various bone volume fractions (from 0.149 to 0.471) were imaged using a micro-CT device. The acquired bone STL models and implant (Brånemark, Straumann, Ankylos) were merged into a three-dimensional finite elements structure. The mean displacement value for all implants was 3.1 ±1.2 µm. Displacements were lower in the group with a strong BIC. The results indicated that the maximum strain values of cortical and cancellous bone increased with lower bone density. Strain distribution is the first and foremost dependent on the shape of bone and architecture of cancellous bone. The geometry of the implant, thread patterns, grade of bone atrophy and BIC all affect the displacement and micro-strain on the mandible bone. Preoperative finite element analysis could offer improved predictability in the long-term outlook of dental implant restorations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. An Analysis of Patient Perceptions and Expectations to Dental Implants: Is There a Significant Effect on Long-Term Satisfaction Levels?

    PubMed Central

    2017-01-01

    Here we present an analysis of patient perceptions and expectations to dental implant placement and their prosthetic reconstruction, to then consider whether they have an effect on long-term satisfaction levels. A Post-Treatment Completion Questionnaire was designed to analyse whether patient satisfaction is influenced by age and/or gender; has an effect on patient-reported self-confidence levels; contributes to increased levels of oral hygiene; provides further insight into the average pain levels during and after the surgical intervention; or influences further acceptance of dental implant surgery. And then whether relationships exist between any of these factors. 182 consecutive patients completed the survey: 68 males and 114 females (age mean 64.68 years ± 11.23 SD); the average number of months since treatment completion was 37.4 (males) and 62.6 (females). There is a significant relationship between comfort rating and “how well informed” the patient was (p = 0.015). A significantly positive relationship exists between “considering dental implants in the future” and “overall experience” (p = 0.001). A significantly positive relationship exists between “overall satisfaction with appearance” and “satisfaction with comfort” (p = 0.011). A significant relationship exists between “overall satisfaction with appearance,” “satisfaction with comfort,” and “overall satisfaction with experience” (p = 0.001). The results amplify the need to transmit logical, truthful information to patients when dental implant treatment is being considered. The “fully informed” patient will have realistic expectations that lead to high degrees of satisfaction. PMID:28928771

  13. Accidental aspiration in a patient with Parkinson's disease during implant-supported prosthesis construction: a case report.

    PubMed

    Deliberador, Tatiana Miranda; Marengo, Gláucia; Scaratti, Rodrigo; Giovanini, Allan Fernando; Zielak, João César; Baratto Filho, Flares

    2011-01-01

    This article reports on a case history of an elderly patient with Parkinson's disease (PD) who sought treatment at a private dental office. His chief complaint was "difficulty in eating due to an illfitting prosthesis." Laboratory tests and oral radiographs were made. The surgical placement of an implant was done and, subsequently, an implant-supported prosthesis was fitted for the patient. During the impression for the construction of the implant-supported prosthesis, the patient accidentally aspirated the implant screwdriver. The object was found in the lower right lobe of the bronchus, and its removal was necessary in a hospital using bronchoscopy under general anesthesia. Patients with PD are considered at risk of aspirating and/or ingesting dental instruments. Short treatment periods are recommended, preferably during the morning, when the medication prescribed for PD is most effective. When treating patients who have a risk for aspirating and ingesting small objects, it is important to treat them in a more vertical position, and small-sized objects should be secured with dental floss to aid retrieval. © 2011 Special Care Dentistry Association and Wiley Periodicals, Inc.

  14. Pathological mandibular fracture: A severe complication of periimplantitis

    PubMed Central

    Rodriguez-Campo, Francisco; Naval-Parra, Beatriz; Sastre-Pérez, Jesús

    2015-01-01

    Nowadays, dental implant treatment is a very common option for patients even in medical compromised conditons. Some complications related to them have been described. Periimplantitis (PI) is one of the biggest concerns complications of these kind of treatments, probably has a multifactorial aethiology. Usually the consequences of PI are the loss of the implants and prostheses, expenses of money and time for dentists and patients. Very often PI implies the necesity of repeating the treatment . Pathological mandibular fracture due to PI is a severe but infrequent complication after dental implant treatment, especially after PI. In this study we present three cases of mandibular pathologic fractures among patients with different medical and dental records but similar management: two of them had been treated years ago of oral squamous cell carcinoma with surgery and radiotherapy, the other patient received oral bisphosphonates for osteoporosis some years after implantation. We analized the causes, consequences and posible prevention of these fractures as well as the special features of this kind of mandibular fractures and the different existing treatments. Key words:Periimplantitis, pathological mandibular fracture, mandibular atrophy, bicortical implants. PMID:26155355

  15. Pathological mandibular fracture: A severe complication of periimplantitis.

    PubMed

    Naval-Gías, Luis; Rodriguez-Campo, Francisco; Naval-Parra, Beatriz; Sastre-Pérez, Jesús

    2015-04-01

    Nowadays, dental implant treatment is a very common option for patients even in medical compromised conditons. Some complications related to them have been described. Periimplantitis (PI) is one of the biggest concerns complications of these kind of treatments, probably has a multifactorial aethiology. Usually the consequences of PI are the loss of the implants and prostheses, expenses of money and time for dentists and patients. Very often PI implies the necesity of repeating the treatment . Pathological mandibular fracture due to PI is a severe but infrequent complication after dental implant treatment, especially after PI. In this study we present three cases of mandibular pathologic fractures among patients with different medical and dental records but similar management: two of them had been treated years ago of oral squamous cell carcinoma with surgery and radiotherapy, the other patient received oral bisphosphonates for osteoporosis some years after implantation. We analized the causes, consequences and posible prevention of these fractures as well as the special features of this kind of mandibular fractures and the different existing treatments. Key words:Periimplantitis, pathological mandibular fracture, mandibular atrophy, bicortical implants.

  16. An audit of implant practice websites: content and regulatory compliance.

    PubMed

    Raimundo, H; Robinson, P K

    2014-12-01

    To audit the content of dental practice websites offering dental implant services against a framework based on the GDC 2012 Guidelines for Ethical Advertising and other relevant advertising standards. An audit framework was constructed and applied to the top fifty websites resulting from a Google UK search using the search term 'dental implant specialist'. Compliance with many elements of the GDC Guidance remains poor. Sixty-eight percent of websites claimed that the practitioner providing the service was a GDC registered specialist, though examples were found where this claim was unfounded. Fourteen percent of practice websites claimed that the service was being carried out by an 'implant specialist' and 16% claimed the practitioner was an 'implantologist'; the majority of sites using these terms (10%) involved practitioners that had no specialist status. The display of potentially misleading memberships and fellowships of a range of dental associations, academies, societies and foundations remains common (52%), as does the adoption of the title 'Dr' (60%). Comparison with earlier studies indicates that compliance with recent GDC standards is generally improving, though whether the pace of improvement is seen as acceptable or not is something that policymakers and regulatory authorities may need to consider further.

  17. Influence of the Diameter of Dental Implants Replacing Single Molars: 3- to 6-Year Follow-Up.

    PubMed

    Mendonça, Jose Alfredo; Senna, Plinio Mendes; Francischone, Carlos Eduardo; Francischone Junior, Carlos Eduardo; Sotto-Maior, Bruno Salles

    The aim of this study was to evaluate the influence of the implant diameter on marginal bone remodeling around dental implants replacing single molars after a follow-up period of 3 to 6 years. Patients who received dental implants with an external hexagon platform in healed sites to support a single metal-ceramic crown in the molar region were recalled to the office. The implantation sites and implant length information were recorded, and the implants were divided according to the implant diameter: regular (RP) or wide (WP). Each implant was assessed by digital periapical radiography, using a sensor holder for the paralleling technique. The marginal bone remodeling was determined as the distance from the implant platform to the first bone-to-implant contact, and the known implant length was used to calibrate the images in the computer software. The follow-up measurements were compared with those obtained from the radiograph taken at the time of prosthetic loading to determine the late bone remodeling. The independent t test was used to compare data. A total of 67 implants from 46 patients were evaluated with a mean follow-up period of 4.5 ± 1.0 years. The RP group comprised 36 implants from 29 patients (mean age: 58.3 ± 10.6 years), while 31 implants from 17 patients (mean age: 56.9 ± 11.5 years) were included in the WP group. The RP group presented lower survival rates (86.1%) than the WP group (100.0%). Similar marginal bone loss (P < .05) was identified for the RP and WP groups (1.35 ± 0.96 mm and 1.06 ± 0.70 mm, respectively). Although wide-diameter implants exhibited lower incidence failures, the bone levels were similar after the prosthetic loading around regular- and wide-diameter implants supporting single molar crowns.

  18. Scanning Electron Microscope (SEM) Evaluation of the Interface between a Nanostructured Calcium-Incorporated Dental Implant Surface and the Human Bone.

    PubMed

    Mangano, Francesco; Raspanti, Mario; Maghaireh, Hassan; Mangano, Carlo

    2017-12-17

    Purpose . The aim of this scanning electron microscope (SEM) study was to investigate the interface between the bone and a novel nanostructured calcium-incorporated dental implant surface in humans. Methods . A dental implant (Anyridge ® , Megagen Implant Co., Gyeongbuk, South Korea) with a nanostructured calcium-incorporated surface (Xpeed ® , Megagen Implant Co., Gyeongbuk, South Korea), which had been placed a month earlier in a fully healed site of the posterior maxilla (#14) of a 48-year-old female patient, and which had been subjected to immediate functional loading, was removed after a traumatic injury. Despite the violent trauma that caused mobilization of the fixture, its surface appeared to be covered by a firmly attached, intact tissue; therefore, it was subjected to SEM examination. The implant surface of an unused nanostructured calcium-incorporated implant was also observed under SEM, as control. Results . The surface of the unused implant showed a highly-structured texture, carved by irregular, multi-scale hollows reminiscent of a fractal structure. It appeared perfectly clean and devoid of any contamination. The human specimen showed trabecular bone firmly anchored to the implant surface, bridging the screw threads and filling the spaces among them. Conclusions . Within the limits of this human histological report, the sample analyzed showed that the nanostructured calcium-incorporated surface was covered by new bone, one month after placement in the posterior maxilla, under an immediate functional loading protocol.

  19. Effects of the 3D bone-to-implant contact and bone stiffness on the initial stability of a dental implant: micro-CT and resonance frequency analyses.

    PubMed

    Hsu, J T; Huang, H L; Tsai, M T; Wu, A Y J; Tu, M G; Fuh, L J

    2013-02-01

    This study investigated the effects of bone stiffness (elastic modulus) and three-dimensional (3D) bone-to-implant contact ratio (BIC%) on the primary stabilities of dental implants using micro-computed tomography (micro-CT) and resonance frequency analyses. Artificial sawbone models with five values of elastic modulus (137, 123, 47.5, 22, and 12.4 MPa) comprising two types of trabecular structure (solid-rigid and cellular-rigid) were investigated for initial implant stability quotient (ISQ), measured using the wireless Osstell resonance frequency analyzer. Bone specimens were attached to 2 mm fibre-filled epoxy sheets mimicking the cortical shell. ISQ was measured after placing a dental implant into the bone specimen. Each bone specimen with an implant was subjected to micro-CT scanning to calculate the 3D BIC% values. The similarity of the cellular type of artificial bone to the trabecular structure might make it more appropriate for obtaining accurate values of primary implant stability than solid-bone blocks. For the cellular-rigid bone models, the ISQ increased with the elastic modulus of cancellous bone. The regression correlation coefficient was 0.96 for correlations of the ISQ with the elasticity of cancellous bone and with the 3D BIC%. The initial implant stability was moderately positively correlated with the elasticity of cancellous bone and with the 3D BIC%. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. [Influence of trabecular microstructure modeling on finite element analysis of dental implant].

    PubMed

    Shen, M J; Wang, G G; Zhu, X H; Ding, X

    2016-09-01

    To analyze the influence of trabecular microstructure modeling on the biomechanical distribution of implant-bone interface with a three-dimensional finite element mandible model of trabecular structure. Dental implants were embeded in the mandibles of a beagle dog. After three months of the implant installation, the mandibles with dental implants were harvested and scaned by micro-CT and cone-beam CT. Two three-dimensional finite element mandible models, trabecular microstructure(precise model) and macrostructure(simplified model), were built. The values of stress and strain of implant-bone interface were calculated using the software of Ansys 14.0. Compared with the simplified model, the precise models' average values of the implant bone interface stress increased obviously and its maximum values did not change greatly. The maximum values of quivalent stress of the precise models were 80% and 110% of the simplified model and the average values were 170% and 290% of simplified model. The maximum and average values of equivalent strain of precise models were obviously decreased, and the maximum values of the equivalent effect strain were 17% and 26% of simplified model and the average ones were 21% and 16% of simplified model respectively. Stress and strain concentrations at implant-bone interface were obvious in the simplified model. However, the distributions of stress and strain were uniform in the precise model. The precise model has significant effect on the distribution of stress and strain at implant-bone interface.

  1. The Impact of In Vitro Accelerated Aging, Approximating 30 and 60 Years In Vivo, on Commercially Available Zirconia Dental Implants.

    PubMed

    Monzavi, Mona; Noumbissi, Sammy; Nowzari, Hessam

    2017-04-01

    Despite increased popularity of Zirconia dental implants, concerns have been raised regarding low temperature degradation (LTD) and its effect on micro-structural integrity. This study evaluated the effect of LTD on four types of Zirconia dental implants at 0, 30, and 60 years of artificial aging. The impact of aging on t-m transformation and micro crack formation was measured. Accelerated aging at 15 and 30 hours, approximating 30 and 60 years in vivo, aged 36 Zirconia dental implants: Z systems ® (A), Straumann ® (B), Ceraroot ® (C), and Zeramex ® (D). Focused ion beam-scanning electron microscopic analysis determined the micro structural features, phase transformation, and the formation of micro cracks. At 15 hours, type A implant presented with micro cracks and t-m transformation of 0.9 µm and 3.1 µm, respectively. At 30 hours, micro cracks remained shallow (1 µm). At 15 hours, type B implant presented micro cracks (0.7 µm) and grain transformation (1.2 µm). At 30 hours, these features remained superficial at 0.6 and 1.5 µm, respectively. Type C implant presented surface micro cracks of 0.3 µm at 15 hours. The depth of t-m transformation slightly increased to 1.4 µm. At 30 hours, number of micro cracks increased at the surface to an average depth of 1.5 µm. Depth of t-m transformation increased to an average of 2.5 µm. At 15 hours, micro cracks remained superficial (0.8 µm) for type D implant and depth of t-m transformation increased to 2.3 µm. At 30 hours, the depth of micro cracks increased to an average of 1.3 µm followed by increased t-m transformation to a depth of 4.1 µm. Depth of grain transformation remained within 1-4 µm from the surface. The effect of aging was minimal for all Zirconia implants. © 2016 Wiley Periodicals, Inc.

  2. 3D Metal Printing - Additive Manufacturing Technologies for Frameworks of Implant-Borne Fixed Dental Prosthesis.

    PubMed

    Revilla León, M; Klemm, I M; García-Arranz, J; Özcan, M

    2017-09-01

    An edentulous patient was rehabilitated with maxillary metal-ceramic and mandibular metal-resin implant-supported fixed dental prosthesis (FDP). Metal frameworks of the FDPs were fabricated using 3D additive manufacturing technologies utilizing selective laser melting (SLM) and electron beam melting (EBM) processes. Both SLM and EBM technologies were employed in combination with computer numerical control (CNC) post-machining at the implant interface. This report highlights the technical and clinical protocol for fabrication of FDPs using SLM and EBM additive technologies. Copyright© 2017 Dennis Barber Ltd.

  3. Numerical verification of two-component dental implant in the context of fatigue life for various load cases.

    PubMed

    Szajek, Krzysztof; Wierszycki, Marcin

    2016-01-01

    Dental implant designing is a complex process which considers many limitations both biological and mechanical in nature. In earlier studies, a complete procedure for improvement of two-component dental implant was proposed. However, the optimization tasks carried out required assumption on representative load case, which raised doubts on optimality for the other load cases. This paper deals with verification of the optimal design in context of fatigue life and its main goal is to answer the question if the assumed load scenario (solely horizontal occlusal load) leads to the design which is also "safe" for oblique occlussal loads regardless the angle from an implant axis. The verification is carried out with series of finite element analyses for wide spectrum of physiologically justified loads. The design of experiment methodology with full factorial technique is utilized. All computations are done in Abaqus suite. The maximal Mises stress and normalized effective stress amplitude for various load cases are discussed and compared with the assumed "safe" limit (equivalent of fatigue life for 5e6 cycles). The obtained results proof that coronial-appical load component should be taken into consideration in the two component dental implant when fatigue life is optimized. However, its influence in the analyzed case is small and does not change the fact that the fatigue life improvement is observed for all components within whole range of analyzed loads.

  4. Biomechanical evaluation of different abutment-implant connections - A nonlinear finite element analysis

    NASA Astrophysics Data System (ADS)

    Ishak, Muhammad Ikman; Shafi, Aisyah Ahmad; Rosli, M. U.; Khor, C. Y.; Zakaria, M. S.; Rahim, Wan Mohd Faizal Wan Abd; Jamalludin, Mohd Riduan

    2017-09-01

    The success of dental implant surgery is majorly dependent on the stability of prosthesis to anchor to implant body as well as the integration of implant body to bone. The attachment between dental implant body and abutment plays a vital role in attributing to the stability of dental implant system. A good connection between implant body cavity to abutment may minimize the complications of abutment loosening and implant fractures as widely reported in clinical findings. The aim of this paper is to investigate the effect of different abutment-implant connections on stress dispersion within the abutment and implant bodies as well as displacement of implant body via three-dimensional (3-D) finite element analysis (FEA). A 3-D model of mandible was reconstructed from computed tomography (CT) image datasets using an image-processing software with the selected region of interest was the left side covering the second premolar, first molar and second molar regions. The bone was modelled as compact (cortical) and porous (cancellous) structures. Besides, three implant bodies and three generic models of abutment with different types of connections - tapered interference fit (TIF), tapered integrated screwed-in (TIS) and screw retention (SR) were created using computer-aided design (CAD) software and all models were then analysed via 3D FEA software. Occlusal forces of 114.6 N, 17.2 N and 23.4 N were applied in the axial, lingual and mesio-distal directions, respectively, on the top surface of first molar crown. All planes of the mandibular bone model were rigidly fixed. The result exhibited that abutment with TIS connection produced the most favourable stress and displacement outcomes as compared to other attachment types. This is due to the existence of integrated screw at the bottom portion of tapered abutment which increases the motion resistance.

  5. [Aftercare for durability and profitability of single-unit and multi-unit fixed dental prostheses].

    PubMed

    de Baat, C; van Loveren, C; van der Maarel-Wierink, C D; Witter, D J; Creugers, N H J

    2013-01-01

    An important aim ofa treatment with single-unit and multi-unit fixed dental prostheses is a durable and profitable treatment outcome. That requires aftercare, too. First, the frequency of routine oral examinations should be assessed, using an individual risk profile. The objectives of the routine oral examinations are the prevention and, when necessary, the treatment of pathological conditions and complications. With regard to prevention, attention should be paid to information and instruction, oral biofilm and calculus, non-functional activities, hard tooth tissues, periodontal and peri-implant tissues, and saliva. Subsequently, it can be determined whether the intended durability and profitability have been achieved or can still be achieved, whether or not through indicated adjustments. Special attention should be paid to endodontically treated teeth. Restorative, repair or replacement treatments may be indicated in case ofcomplications, such as loose single- or multi-unitfixed dental prosthesis, fracture of a fixed dental prosthesis unit, lost tooth pulp vitality, tooth root fracture, and implant or implant abutment problems.

  6. Comparing Short Dental Implants to Standard Dental Implants: Protocol for a Systematic Review.

    PubMed

    Rokn, Amir Reza; Keshtkar, Abbasali; Monzavi, Abbas; Hashemi, Kazem; Bitaraf, Tahereh

    2018-01-18

    Short dental implants have been proposed as a simpler, cheaper, and faster alternative for the rehabilitation of atrophic edentulous areas to avoid the disadvantages of surgical techniques for increasing bone volume. This review will compare short implants (4 to 8 mm) to standard implants (larger than 8 mm) in edentulous jaws, evaluating on the basis of marginal bone loss (MBL), survival rate, complications, and prosthesis failure. We will electronically search for randomized controlled trials comparing short dental implants to standard dental implants in the following databases: PubMed, Web of Science, EMBASE, Scopus, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov with English language restrictions. We will manually search the reference lists of relevant reviews and the included articles in this review. The following journals will also be searched: European Journal of Oral Implantology, Clinical Oral Implants Research, and Clinical Implant Dentistry and Related Research. Two reviewers will independently perform the study selection, data extraction and quality assessment (using the Cochrane Collaboration tool) of included studies. All meta-analysis procedures including appropriate effect size combination, sub-group analysis, meta-regression, assessing publication or reporting bias will be performed using Stata (Statacorp, TEXAS) version 12.1. Short implant effectiveness will be assessed using the mean difference of MBL in terms of weighted mean difference (WMD) and standardized mean difference (SMD) using Cohen's method. The combined effect size measures in addition to the related 95% confidence intervals will be estimated by a fixed effect model. The heterogeneity of the related effect size will be assessed using a Q Cochrane test and I2 measure. The MBL will be presented by a standardized mean difference with a 95% confidence interval. The survival rate of implants, prostheses failures, and complications will be reported using a risk ratio at 95% confidence interval (P<.05). The present protocol illustrates an appropriate method to perform the systematic review and ensures transparency for the completed review. The results will be published in a peer-reviewed journal and social networks. In addition, an ethics approval is not considered necessary. PROSPERO registration number: CRD42016048363; https://www.crd.york.ac.uk/PROSPERO/ display_record.asp?ID=CRD42016048363 (Archived by WebCite at http://www.webcitation.org/6wZ7Fntry). ©Amir Reza Rokn, Abbasali Keshtkar, Abbas Monzavi, Kazem Hashemi, Tahereh Bitaraf. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 18.01.2018.

  7. Random spectrum loading of dental implants: An alternative approach to functional performance assessment.

    PubMed

    Shemtov-Yona, K; Rittel, D

    2016-09-01

    The fatigue performance of dental implants is usually assessed on the basis of cyclic S/N curves. This neither provides information on the anticipated service performance of the implant, nor does it allow for detailed comparisons between implants unless a thorough statistical analysis is performed, of the kind not currently required by certification standards. The notion of endurance limit is deemed to be of limited applicability, given unavoidable stress concentrations and random load excursions, that all characterize dental implants and their service conditions. We propose a completely different approach, based on random spectrum loading, as long used in aeronautical design. The implant is randomly loaded by a sequence of loads encompassing all load levels it would endure during its service life. This approach provides a quantitative and comparable estimate of its performance in terms of lifetime, based on the very fact that the implant will fracture sooner or later, instead of defining a fatigue endurance limit of limited practical application. Five commercial monolithic Ti-6Al-4V implants were tested under cyclic, and another 5 under spectrum loading conditions, at room temperature and dry air. The failure modes and fracture planes were identical for all implants. The approach is discussed, including its potential applications, for systematic, straightforward and reliable comparisons of various implant designs and environments, without the need for cumbersome statistical analyses. It is believed that spectrum loading can be considered for the generation of new standardization procedures and design applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Analysis of risk factors for cluster behavior of dental implant failures.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-08-01

    Some studies indicated that implant failures are commonly concentrated in few patients. To identify and analyze cluster behavior of dental implant failures among subjects of a retrospective study. This retrospective study included patients receiving at least three implants only. Patients presenting at least three implant failures were classified as presenting a cluster behavior. Univariate and multivariate logistic regression models and generalized estimating equations analysis evaluated the effect of explanatory variables on the cluster behavior. There were 1406 patients with three or more implants (8337 implants, 592 failures). Sixty-seven (4.77%) patients presented cluster behavior, with 56.8% of all implant failures. The intake of antidepressants and bruxism were identified as potential negative factors exerting a statistically significant influence on a cluster behavior at the patient-level. The negative factors at the implant-level were turned implants, short implants, poor bone quality, age of the patient, the intake of medicaments to reduce the acid gastric production, smoking, and bruxism. A cluster pattern among patients with implant failure is highly probable. Factors of interest as predictors for implant failures could be a number of systemic and local factors, although a direct causal relationship cannot be ascertained. © 2017 Wiley Periodicals, Inc.

  9. A Review on Biomaterials in Dental Implantology

    PubMed Central

    Ananth, Hariprasad; Kundapur, Vinaya; Mohammed, H. S.; Anand, M.; Amarnath, G. S.; Mankar, Sunil

    2015-01-01

    Implants have been gaining popularity amongst the patients and frequently are being considered as a first treatment option. Modern dentistry is beginning to understand, realize, and utilize the benefits of biotechnology in health care. Study of material sciences along with the biomechanical sciences provides optimization of design and material concepts for surgical implants. Biocompatibility is property of implant material to show favorable response in given biological environment. In attempt to replace a missing tooth many biomaterials have been evolved as implants for many years in an effort to create an optimal interaction between the body and the implanted material. With all the advancements and developments in the science and technology, the materials available for dental implants also improved. The choice of material for a particular implant application will generally be a compromise to meet many different required properties. There is, however, one aspect that is always of prime importance that how the tissue at the implant site responds to the biochemical disturbance that a foreign material presents. PMID:26508905

  10. [Establishment and management of electronic appointment library for dental implant patients].

    PubMed

    Dong, Zheng-jie; Xu, Kan

    2013-10-01

    To design an excel form which can prompt dental implant patient appointment through color change, which can scientifically manage implant EMR library through appropriate interlinkage and number. An excel form based on operating system Windows XP was designed and software 2003 Microsoft excel was used, which was configured to change color with the passage of time by the use of command "conditional format". An excel form was designed. The color turned to red automatically on the day the patient underwent implant surgery. It turned to yellow when the patient recalled 2 weeks after the first operation, to green when the patient underwent secondary operation. It was designed to be gray when all the procedures of implant restoration was finished. In addition, we could know patients' main implant situation through directly opening his EMR when clicking on his name or number. Dentists can remind the implant patient appointment schedule through color change of an excel form, and can consult the implant patient EMR directly through interlinkage or number.

  11. Photogrammetric determination of discrepancies between actual and planned position of dental implants

    NASA Astrophysics Data System (ADS)

    Forlani, G.; Rivara, F.

    2014-05-01

    The paper describes the design and testing of a photogrammetric measurement protocol set up to determine the discrepancies between the planned and actual position of computer-guided template-based dental implants. Two moulds with the implants positioned in pre- and post- intervention are produced and separately imaged with a highly redundant block of convergent images; the model with the implants is positioned on a steel frame with control points and with suitable targets attached. The theoretical accuracy of the system is better than 20 micrometers and 0.3-0.4° respectively for positions of implants and directions of implant axes. In order to compare positions and angles between the planned and actual position of an implant, coordinates and axes directions are brought to a common reference system with a Helmert transformation. A procedure for comparison of positions and directions to identify out-of-tolerance discrepancies is presented; a numerical simulation study shows the effectiveness of the procedure in identifying the implants with significant discrepancies between pre- and post- intervention.

  12. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.

    PubMed

    Ding, Xi; Zhu, Xing-Hao; Liao, Sheng-Hui; Zhang, Xiu-Hua; Chen, Hong

    2009-07-01

    To establish a 3D finite element model of a mandible with dental implants for immediate loading and to analyze stress distribution in bone around implants of different diameters. Three mandible models, embedded with thread implants (ITI, Straumann, Switzerland) with diameters of 3.3, 4.1, and 4.8 mm, respectively, were developed using CT scanning and self-developed Universal Surgical Integration System software. The von Mises stress and strain of the implant-bone interface were calculated with the ANSYS software when implants were loaded with 150 N vertical or buccolingual forces. When the implants were loaded with vertical force, the von Mises stress concentrated on the mesial and distal surfaces of cortical bone around the neck of implants, with peak values of 25.0, 17.6 and 11.6 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains (5854, 4903, 4344 muepsilon) were located on the buccal cancellous bone around the implant bottom and threads of implants. The stress and strain were significantly lower (p < 0.05) with the increased diameter of implant. When the implants were loaded with buccolingual force, the peak von Mises stress values occurred on the buccal surface of cortical bone around the implant neck, with values of 131.1, 78.7, and 68.1 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains occurred on the buccal surface of cancellous bone adjacent to the implant neck, with peak values of 14,218, 12,706, and 11,504 microm, respectively. The stress of the 4.1-mm diameter implants was significantly lower (p < 0.05) than those of 3.3-mm diameter implants, but not statistically different from that of the 4.8 mm implant. With an increase of implant diameter, stress and strain on the implant-bone interfaces significantly decreased, especially when the diameter increased from 3.3 to 4.1 mm. It appears that dental implants of 10 mm in length for immediate loading should be at least 4.1 mm in diameter, and uniaxial loading to dental implants should be avoided or minimized.

  13. Two-stage implant systems.

    PubMed

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of osseointegration. New types of reinforcements for dental implants and the use of growth factors to augment bone regeneration so that implants can be placed more easily are now being actively investigated.

  14. Influence of implant diameter in the displacement of dental implants in trabecular bovine bone under a static lateral load: experimental results and computational modeling.

    PubMed

    Engelke, Wilfried; Decco, Oscar A; Cura, Andrea C; Maldonado, Isai; Crippa, Federico G

    2014-12-01

    Primary stability and micromovement of dental implants depend on structural properties of the surrounding bone and on implant dimension and design. The purpose of this study was to provide objective data for the influence of implant diameter on the displacement of titanium screw implants. Ninety Semados implants (length 15 mm, diameter 3.25, 3.75, and 4.5 mm; Bego, Bremen, Germany) were inserted in trabecular bone specimens. All implants were inserted with a torque up to 30 N·cm and loaded horizontally with 10, 20, and 30 N for 2 seconds. All implants showed primary stability. With increasing force, a gradual increase of micromovement was observed (Kruskal-Wallis test, P = 0.000). No significant differences were found (Kruskal-Wallis test, P = 0.148) comparing different diameters for every force. Variation of the diameter of standard implants between 3.25 and 4.5 mm does not seem to influence the primary stability in trabecular bone specimen. Differences between experimental and computational results may be due to the simplification used when modeling.

  15. Denture reconstruction of the edentulous upper jaw in cleft palate using implants--clinical report.

    PubMed

    Dostálová, T; Holakovský, J; Bartonová, M; Seydlová, M; Smahel, Z

    2007-01-01

    Early prosthodontic therapy (usually at around 18 years of age) often leads to early loss of teeth and in extreme cases to complete loss of dentition at between 40 and 50 years of age. This report describes the clinical features of two middle-aged cleft patients. Edentulous maxilla with cleft defect was treated with 6 implants supported by fixed appliance. Treatment of the whole dental arch on the basis of implants is currently frequently used as it provides a possibility of thorough functional and aesthetic therapy to a patient. The biomechanics of the reconstruction enables individual adjustment of the shape of the dental arch. The problem in cleft patients involves other diameter relations in the dental arch caused by the defect alone or also by affecting the growth of the maxillary segment by surgery. A potentially removable framework is therefore the main method of choice because the position of the implants must be prosthetically modified.

  16. Implant support for removable partial overdentures: a case report.

    PubMed

    Halterman, S M; Rivers, J A; Keith, J D; Nelson, D R

    1999-01-01

    Functional stability and the preservation of remaining alveolar bone are primary, and often elusive, goals when restoring the partially edentulous arch. The incorporation of dental implants for the partial support of removable prostheses offers a practical adjunct in the fulfillment of these objectives. Planning for complex courses of treatment that include dental implants requires close coordination between the surgeon and the restorative dentist. Decisions that deal with type, location, size, number of implant fixtures, and design of the prosthesis are critical. All of these areas must be discussed and established as acceptable to the patient and each clinician before the initiation of treatment. In this report, we present a course of patient treatment in which a removable partial denture is supported by natural remaining teeth in conjunction with osseointegrated implants.

  17. Guided bone regeneration using nonexpanded polytetrafluoroethylene membranes in preparation for dental implant placements--a report of 420 cases.

    PubMed

    Barboza, Eliane Porto; Stutz, Bianca; Ferreira, Vinícius Farias; Carvalho, Waldimir

    2010-02-01

    The biologic principle of guided bone regeneration has been successfully used to prevent bone loss in extraction sites. This study comprises 420 cases of alveolar ridge maintenance in preparation for dental implant placements. Nonexpanded polytetrafluoroethylene membranes were positioned over all extraction sites and left intentionally exposed. Lyophilized mineralized bone allografts were used to prevent membrane collapse when buccal bone walls were lost. Membranes were removed at week 4. At the time of implant placements, all sites presented soft tissue compatibility with keratinized gingiva. The mucogingival junction position seemed to be preserved. Exposed nonexpanded polytetrafluoroethylene membranes associated, or not, with bone graft provide tissue formation suitable for implant placement.

  18. Comparative Analysis of Structural Responses of Rat Subcutaneous Fat on the Implantation of Samples of Polymethyl Methacrylate with Hydrophobic and Hydrophilic Surface.

    PubMed

    Kudasova, E O; Vlasova, L F; Semenov, D E; Lushnikova, E L

    2017-03-01

    Morphological analysis of the subcutaneous fat was performed in rats after subcutaneous implantation of basic dental plastic materials with different hydrophobic and hydrophilic properties. It was shown that subcutaneous implantation of dental plastics with mostly hydrophobic surface and low biocompatibility induced destructive and inflammatory processes of various intensities, sometimes with allergic component; morphological signs of processes persisted for 6 weeks. Modification of basic plastics using glow-discharge plasma and enhancement of their hydrophilicity and biocompatibility significantly reduced the intensity of destructive and inflammatory processes and ensured more rapid (in 2 weeks) repair of the destroyed tissues with the formation of fibrous capsule around the implant.

  19. Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

    PubMed

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-03-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.

  20. Correction of Large Oro-antral Communications From Previously Failed Implant Treatment: Reconstruction of Hard and Soft Tissues.

    PubMed

    Petrungaro, Paul S; Gonzalez, Santiago; Villegas, Carlos

    2018-02-01

    As dental implants become more popular for the treatment of partial and total edentulism and treatment of "terminal dentitions," techniques for the management of the atrophic posterior maxillae continue to evolve. Although dental implants carry a high success rate long term, attention must be given to the growing numbers of revisions or retreatment of cases that have had previous dental implant treatment and/or advanced bone replacement procedures that, due to either poor patient compliance, iatrogenic error, or poor quality of the pre-existing alveolar and/or soft tissues, have led to large osseous defects, possibly with deficient soft-tissue volume. In the posterior maxillae, where the poorest quality of bone in the oral cavity exists, achieving regeneration of the alveolar bone and adequate volume of soft tissue remains a complex procedure. This is made even more difficult when dealing with loss of dental implants previously placed, aggressive bone reduction required in various implant procedures, and/or residual sinus infections precluding proper closure of the oral wound margins. The purpose of this article is to outline a technique for the total closure of large oro-antral communications, with underlying osseous defects greater than 15 mm in width and 30 mm in length, for which multiple previous attempts at closure had failed, to achieve not only the reconstruction of adequate volume and quality of soft tissues in the area of the previous fistula, but also total regeneration of the osseous structures in the area of the large void.

  1. The rationale for the introduction of implant dentistry into the dental curriculum.

    PubMed

    Lang, N P; De Bruyn, H

    2009-02-01

    This paper provides arguments for the introduction of implant dentistry into the undergraduate curriculum. The survival of teeth is very high when disease is diagnosed and treated properly and maintenance is taken care of. Nevertheless, tooth replacements by fixed and removable prostheses are highly prevalent. It is expected that dentists will face a dramatically increased need to care for elderly patients and partially edentulous patients. Hence, the demand for implant reconstructions will be substantial and more appropriately trained and competent health professionals will be needed. Increasing demands of the patient regarding aesthetics and function will influence the demands for implant therapy. The improvement of oral function and subjective chewing comfort, the preservation of tooth structures or existing reconstructions and the replacement of missing, strategically important teeth are major indications for implant placement. From both a biological and an economical point of view, the single tooth replacement with an implant is the first choice in situations with no or minimally restored neighbouring teeth compared with conventional bridgework. Stability of full dentures represent a major problem especially for the mandible. It is well documented that placement of two implants supporting an overdenture substantially improve chewing capacity, increase quality of life and is a simple and cost-effective treatment thus rendering such treatment a 'standard of care' procedure. There is no doubt that dental students should learn to incorporate the indication of oral implants in their overall treatment planning. Therefore, they will have to understand the basic aspects of healing and tissue integration, basic biomechanical and material science principles as well as surgical and prosthetic techniques. They will have to be able to monitor continuously the peri-implant tissues, render appropriate supportive therapy and cope with biological and technical complications. While it is evident that the surgical procedure per se may require additional competence, the remainder of the aspects mentioned should be taught in the dental curriculum. This should include the attribution of responsibility for maintenance of implants and handling of biological and technical complications. Moreover, it is desirable to include the surgical technique for implant placement for 'straightforward' cases into the dental curriculum. The levels and limitations to which the various aspects of implant dentistry and related skills are to be taught are determined by the academic community. Obviously, ethical and legal aspects of implant dentistry should not be forgotten.

  2. [Dental implantation and soft tissue augmentation after ridge preservation in a molar site: a case report].

    PubMed

    Zhao, L P; Zhan, Y L; Hu, W J; Wang, H J; Wei, Y P; Zhen, M; Xu, T; Liu, Y S

    2016-12-18

    For ideal implant rehabilitation, an adequate bone volume, optical implant position, and stable and healthy soft tissue are required. The reduction of alveolar bone and changes in its morphology subsequent to tooth extraction will result in insufficient amount of bone and adversely affect the ability to optimally place dental implants in edentulous sites. Preservation of alveolar bone volume through ridge preservation has been demonstrated to reduce the vertical and horizontal contraction of the alveolar bone crest after tooth extraction and reduce the need for additional bone augmentation procedures during implant placement. In this case, a patient presented with a mandible molar of severe periodontal disease, the tooth was removed as atraumatically as possible and the graft material of Bio-Oss was loosely placed in the alveolar socket without condensation and covered with Bio-Gide to reconstruct the defects of the alveolar ridge. Six months later, there were sufficient height and width of the alveolar ridge for the dental implant, avoiding the need of additional bone augmentation and reducing the complexity and unpredictability of the implant surgery. Soft tissue defects, such as gingival and connective tissue, played crucial roles in long-term implant success. Peri-implant plastic surgery facilitated development of healthy peri-implant structure able to withstand occlusal forces and mucogingival stress. Six months after the implant surgery, the keratinized gingiva was absent in the buccal of the implant and the vestibular groove was a little shallow. The free gingival graft technique was used to solve the vestibulum oris groove supersulcus and the absence of keratinized gingiva around the implant. The deepening of vestibular groove and broadening of keratinized gingiva were conducive to the long-term health and stability of the tissue surrounding the implant. Implant installation and prosthetic restoration showed favorable outcome after six months.

  3. Satisfaction and Clinical Outcomes Among Patients with Immediately Loaded Mandibular Overdentures Supported by One or Two Dental Implants: Results of a 5-Year Prospective Randomized Clinical Trial.

    PubMed

    Kronstrom, Mats; Davis, Ben; Loney, Robert; Gerrow, Jack; Hollender, Lars

    The purpose of this study was to evaluate patient satisfaction and clinical outcomes among subjects with mandibular overdentures supported by one or two immediately placed dental implants 5 years after loading. Thirty-six subjects (16 men and 20 women) received one or two dental implants in the anterior mandible, and all implants were loaded the day of surgery. Subjects were scheduled for follow-up 3-, 6-, and 12 months after implant placement and thereafter annually for 4 more years. Patient satisfaction scores were measured with the Oral Health Impact Profile-EDENT (OHIPEDENT) questionnaire. Seventeen subjects (7 male and 10 female) with a mean age of 59.4 years (range, 44 to 74 years) were available for the 5-year follow-up examination. Nine subjects with 10 failing implants were excluded during the first year and nine subjects were lost to follow-up. No implants failed between the 12- and 60-month follow-up examinations, and the need for denture maintenance was low. Mean peri-implant bone change was 0.92 mm, and the Spearman test failed to show correlation between the insertion torque value and implant stability quotient. Patient satisfaction scores increased significantly when compared with baseline values and continued to be high for both groups, with no significant differences. Ten implants in nine subjects failed early, but no failures were observed after the 12-month examination. No significant differences were found between subjects in the two groups with respect to implant survival rates and peri-implant bone loss, and patient satisfaction scores continued to be high. Although patient satisfaction and implant success were high during the 12- to 60-month period, the results should be interpreted with caution because of the high number of failing implants and patients lost to follow-up. More research is needed to study outcomes of treatment with immediately loaded mandibular implant overdentures.

  4. Immediate versus early non-occlusal loading of dental implants placed flapless in partially edentulous patients: a 3-year randomized clinical trial.

    PubMed

    Merli, Mauro; Moscatelli, Marco; Mariotti, Giorgia; Piemontese, Matteo; Nieri, Michele

    2012-02-01

    To compare immediate versus early non-occlusal loading of dental implants placed flapless in a 3-year, parallel group, randomized clinical trial. The study was conducted in a private dental clinic between July 2005 and July 2010. Patients 18 years or older were randomized to receive implants for fixed partial dentures in cases of partial edentulism. The test group was represented by immediate non-occlusal implant loading, whereas the control group was represented by early non-occlusal implant loading. The outcome variables were implant failure, complications and radiographic bone level at implant sites 3 years after loading, measured from the implant-abutment junction to the most coronal point of bone-to-implant contact. Randomization was computer-generated with allocation concealment by opaque sequentially numbered sealed envelopes, and the measurer was blinded to group assignment. Sixty patients were randomized: 30 to the immediately loaded group and 30 to the early loaded group. Four patients dropped out; however, the data of all patients were included in the analysis. No implant failure occurred. Two complications occurred in the control group and one in the test group. The mean bone level at 3 years was 1.91 mm for test group and 1.59 mm for control group. The adjusted difference in bone level was 0.26 mm (CI 95% -0.08 to 0.59, p = 0.1232). The null hypothesis of no difference in failure rates, complications and bone level between implants that were loaded immediately or early at 3 years cannot be rejected in this randomized clinical trial. © 2011 John Wiley & Sons A/S.

  5. Randomized controlled multicenter study comparing short dental implants (6 mm) versus longer dental implants (11-15 mm) in combination with sinus floor elevation procedures. Part 2: clinical and radiographic outcomes at 1 year of loading.

    PubMed

    Schincaglia, Gian Pietro; Thoma, Daniel S; Haas, Robert; Tutak, Marcin; Garcia, Abel; Taylor, Thomas D; Hämmerle, Christoph H F

    2015-11-01

    To compare, clinically and radiographically, short dental implants (6 mm) to long implants (11-15 mm) placed with sinus grafting. Participants with 5-7 mm of bone height in the posterior maxilla were randomly allocated to receive short implants (GS) or long implants with sinus grafting (GG). Implants were loaded with single crowns 6 months after placement (PR). Patients were re-evaluated 12 months after loading (FU-1). Outcome variables included: Implant survival rate (CSR), marginal bone level alteration (MBL), periodontal probing depth (PPD), bleeding on probing (BoP), plaque control record (PCR) and crown-to-implant ratios (C/I). Statistical analysis was performed using parametric tests. In 97 subjects, 132 implants were re-evaluated at FU-1. The CSR was 100%. The MBL from implant placement (IP) to (PR) was -0.22 ± 0.4 mm for GG and -0.3 ± 0.45 mm for GS (p < 0.001). MBL from IP to FU-1 was -0.37 ± 0.59 mm for GG and -0.22 ± 0.3 mm for GS (p < 0.001). Intergroup comparisons showed non-significant differences for MBL (p > 0.05), PPD (p = 1) and PCR (p = 0.09). BoP was higher in the GS (p = 0.04). The C/I was 0.99 ± 0.17 for GG and 1.86 ± 0.23 for GS (p < 0.001). No correlation was observed between C/I and MBL, (GG: p = 0.13; GS: p = 0.38). Both treatment modalities provided similar outcomes. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Does milling one-piece titanium dental implants induce osteocyte and osteoclast changes?

    PubMed

    Russe, P; Pascaretti-Grizon, F; Aguado, E; Goyenvale, E; Filmon, R; Baslé, M-F; Chappard, D

    2011-06-01

    One-piece dental implants avoid adverse effects sometimes associated with the traditional implant-abutment interface and may provide a suitable alternative to two-piece implants; however, one-piece implants often need in situ milling, which may exacerbate cell apoptosis from excessive heat at the bone-implant interface and induce secondary crestal bone loss. Twelve implants were placed in the metaphyses of two sheep under general anesthesia. Six implants were milled with a diamond bur while the other six implants remained intact. Animals were euthanized after four days, and bone blocks were harvested. Bone samples were studied without decalcification. Osteocytes were stained with Hoechst 33342 and osteoclasts by the TRAcP reaction. Both cell types, in the cortical and trabecular bone around the implant's cervical region, were counted utilizing morphometric methods. Values were compared to areas at a distance from the cervical region. No difference was observed between milled and unmilled implants, which suggested that the amount of generated heat did not provoke osteocyte loss or induce osteoclastogenesis. Intraoral abutment preparations did not increase cellular apoptosis at the bone-implant interface after four days in the ovine model. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  7. Comparing the Quality of Life of Patients Requesting Dental Implants Before and After Implant.

    PubMed

    Sargozaie, Naser; Moeintaghavi, Amir; Shojaie, Hamid

    2017-01-01

    Tooth loss is a serious life event that impairs two important functions, namely, eating and speaking, and has significant side effects on different aspects of quality of life. These effects are internalized by the individual. The present study aimed to compare the quality of life (QOL) of patients requesting dental implants before and after implant. This analytical cross-sectional study was conducted on patients referred to the Mashhad faculty of Dentistry and private clinics with dental implants in 2015. Patient Quality Of Life (QOL) was assessed using the Oral Impact on Daily Practice (OIDP) questionnaire. Data were analyzed using SPSS software. In this study, the most common problems reported by patients were eating (78%), smiling, laughing, and embarrassment (53%) before surgery. The quality of life associated with eating; speaking clearly; clean teeth or dentures; light physical activities, such as working at home, going out to work or meeting others; smiling; laughing; showing teeth without discomfort and embarrassment; emotional conditions, such as becoming upset quicker than usual, enjoying communication with others ( i.e. , friends, relatives and neighbors); and job-related activities significantly increased after surgery, but QOL associated with the amount of sleep and resting did not improve. No significant association was noted between quality of life after implantation and place of residence, education and gender. In this study, implants had a favorable impact on a patient's quality of life.

  8. Coherent Synchrotron-Based Micro-Imaging Employed for Studies of Micro-Gap Formation in Dental Implants

    NASA Astrophysics Data System (ADS)

    Rack, T.; Zabler, S.; Rack, A.; Stiller, M.; Riesemeier, H.; Cecilia, A.; Nelson, K.

    2011-09-01

    Biocompatible materials such as titanium are regularly applied in oral surgery. Titanium-based implants for the replacement of missing teeth demand a high mechanical precision in order to minimize micro-bacterial leakage, especially when two-piece concepts are used. Synchrotron-based hard x-ray radiography, unlike conventional laboratory radiography, allows high spatial resolution in combination with high contrast even when micro-sized features in such highly attenuating objects are visualized. Therefore, micro-gap formation at interfaces in two-piece dental implants with the sample under different mechanical loads can be studied. We show the existence of micro-gaps in implants with conical connections and study the mechanical behavior of the mating zone of conical implants during loading. The micro-gap is a potential source of implant failure, i.e., bacterial leakage, which can be a stimulus for an inflammatory process.

  9. Coherent Synchrotron-Based Micro-Imaging Employed for Studies of Micro-Gap Formation in Dental Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rack, T.; Stiller, M.; Nelson, K.

    Biocompatible materials such as titanium are regularly applied in oral surgery. Titanium-based implants for the replacement of missing teeth demand a high mechanical precision in order to minimize micro-bacterial leakage, especially when two-piece concepts are used. Synchrotron-based hard x-ray radiography, unlike conventional laboratory radiography, allows high spatial resolution in combination with high contrast even when micro-sized features in such highly attenuating objects are visualized. Therefore, micro-gap formation at interfaces in two-piece dental implants with the sample under different mechanical loads can be studied. We show the existence of micro-gaps in implants with conical connections and study the mechanical behavior ofmore » the mating zone of conical implants during loading. The micro-gap is a potential source of implant failure, i.e., bacterial leakage, which can be a stimulus for an inflammatory process.« less

  10. Biomechanical behaviour of a jawbone loaded with a prosthetic system supported by monophasic and biphasic implants.

    PubMed

    Inchingolo, F; Paracchini, L; DE Angelis, F; Cielo, A; Orefici, A; Spitaleri, D; Santacroce, L; Gheno, E; Palermo, A

    2016-01-01

    Modern implantology is based on the use of endosseous dental implants and on the study of osseointegration processes. The loss of marginal bone around a dental implant can be caused by many factors; the proper distribution of the masticatory loads is important and is closely dependent on the quality and quantity of bone tissue surrounding the implant. In fact, bone has the ability to adapt its microstructure, through processes of resorption and neoformation of new bone matrix, as a result of the mechanical stimuli that are generated during the chewing cycles. The purpose of this article is to redefine in a modern key and in light of current industrial and engineering technology, clinical and biomechanical concepts that characterize the monophasic implants, in order to assess proper use by evaluating the biomechanical differences with the biphasic implants.

  11. Fiber-reinforced composite fixed dental prostheses: two clinical reports.

    PubMed

    Zarow, Maciej; Paisley, Carl Stuart; Krupinski, Jerzy; Brunton, Paul Anthony

    2010-06-01

    Various options are available in clinical practice for the replacement of a single missing tooth, ranging from conventional fixed and removable dental prostheses to a single implant-supported crown. There are situations in which a semipermanent fixed dental prosthesis may be desirable, particularly for patients who have completed orthodontic treatment but are too young to embark on implant therapy. Following advances in fiber-reinforcement technology, fiber-reinforced composite resin (FRC) now represents a lower-cost alternative to traditional metal-ceramic for the construction of resin-bonded prostheses. Two case reports illustrate the use of FRC prostheses as fixed semipermanent_restorations.

  12. Corrosion behaviour of Ti-15Mo alloy for dental implant applications.

    PubMed

    Kumar, Satendra; Narayanan, T S N Sankara

    2008-07-01

    The corrosion behaviour of Ti-15Mo alloy in 0.15M NaCl solution containing varying concentrations of fluoride ions (190, 570, 1140 and 9500 ppm) is evaluated using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and chronoamperometric/current-time transient (CTT) studies to ascertain its suitability for dental implant applications. The study reveals that there is a strong dependence of the corrosion resistance of Ti-15Mo alloy on the concentration of fluoride ions in the electrolyte medium. Increase in fluoride ion concentration from 0 to 9500 ppm shifts the corrosion potential (E(corr)) from -275 to -457 mV vs. SCE, increases the corrosion current density (i(corr)) from 0.31 to 2.30 microA/cm(2), the passive current density (i(pass)) from 0.07 to 7.32 mA/cm(2) and the double-layer capacitance (C(dl)) from 9.63 x 10(-5) to 1.79 x 10(-4)F and reduces the charge transfer resistance (R(ct)) from 6.58 x 10(4) to 6.64 x 10(3)Omega cm(2). In spite of the active dissolution, the Ti-15Mo alloy exhibit passivity at anodic potentials at all concentrations of the fluoride ions studied. In dental implants since the exposure of the alloy will be limited only to its 'neck', the amount of Mo ions released from Ti-15Mo alloy is not likely to have an adverse and hence, in terms of biocompatibility this alloy seems to be acceptable for dental implant applications. The results of the study suggest that Ti-15Mo alloy can be a suitable alternative for dental implant applications.

  13. Significance of crown shape in the replacement of a central incisor with a single implant-supported crown.

    PubMed

    Gobbato, Luca; Paniz, Gianluca; Mazzocco, Fabio; Chierico, Andrea; Tsukiyama, Teppei; Levi, Paul A; Weisgold, Arnold S

    2013-05-01

    When utilizing a single implant-supported crown to replace a central incisor, understanding the final shape of the implant restoration is an important factor to help achieve a successful esthetic outcome. In today's dentistry, tooth shape is a critical factor when dental implant prostheses are considered in the esthetic zone. The major esthetic goal for this type of restoration is to achieve the closest possible symmetry with the adjacent tooth, both at the soft and at the hard tissue levels. The goal of this study was to objectively analyze the significance of natural crown shape when replacing a central incisor with a single implant-supported crown. In this study, we investigated the shape of the crowns of maxillary central incisors in 60 individuals who presented to our clinics with an untreatable central incisor. The presence of a dental diastema, "black triangle," presence or absence of gingival symmetry, and the presence or absence of dental symmetry were recorded in the pre- and postoperative photographs. Out of 60 patients, 33.3% had triangular-shaped crowns, 16.6% square/tapered, and 50% square-shaped crown form. After treatment was rendered, 65% of the triangular group, 40% of the square/tapered group, and 13.3% of the square group required an additional restoration on the adjacent central incisor in order to fulfill the esthetic needs of the patients. Data analysis revealed that if there is a "black triangle," a diastema, or presence of dental or gingival asymmetry, an additional restoration on the adjacent central incisor is often required in order to fulfill esthetic goals. The additional restoration is highly recommended in situations with a triangular crown shape, while it is suggested in cases of square/tapered and square tooth shapes in the presence of a dental diastema.

  14. Metal TiO2 Nanotube Layers for the Treatment of Dental Implant Infections.

    PubMed

    Roguska, Agata; Belcarz, Anna; Zalewska, Justyna; Hołdyński, Marcin; Andrzejczuk, Mariusz; Pisarek, Marcin; Ginalska, Grazyna

    2018-05-23

    Titanium oxide nanotube layers with silver and zinc nanoparticles are attracting increasing attention in the design of bone and dental implants due to their antimicrobial potential and their ability to control host cell adhesion, growth, and differentiation. However, recent reports indicate that the etiology of dental infections is more complex than has been previously considered. Therefore, the antimicrobial potential of dental implants should be evaluated against at least several different microorganisms cooperating in human mouth colonization. In this study, Ag and Zn nanoparticles incorporated into titanium oxide nanotubular layers were studied with regard to how they affect Candida albicans, Candida parapsilosis, and Streptococcus mutans. Layers of titanium oxide nanotubes with an average diameter of 110 nm were fabricated by electrochemical anodization, annealed at 650 °C, and modified with approx. 5 wt % Ag or Zn nanoparticles. The surfaces were examined with the scanning electron microscopy-energy dispersive X-ray analysis, scanning transmission electron microscopy, and X-ray photoelectron spectroscopy techniques and subjected to evaluation of microbial-killing and microbial adhesion-inhibiting potency. In a 1.5 h long adhesion test, the samples were found more effective toward yeast strains than toward S. mutans. In a release-killing test, the microorganisms were almost completely eliminated by the samples, either within 3 h of contact (for S. mutans) or 24 h of contact (for both yeast strains). Although further improvement is advisable, it seems that Ag and Zn nanoparticles incorporated into TiO 2 nanotubular surfaces provide a powerful tool for reducing the incidence of bone implant infections. Their high bidirectional activity (against both Candida species and S. mutans) makes the layers tested particularly promising for the design of dental implants.

  15. [Application of plasma sprayed zirconia coating in dental implant: study in implant].

    PubMed

    Huang, Z F; Wang, Z F; Li, C H; Hao, D; Lan, J

    2018-04-09

    Objective: To investigate the osseointegration of a novel coating-plasma-sprayed zirconia in dental implant. Methods: Zirconia coating on non-thread titanium implant was prepared using plasma spraying, the implant surface morphology, surface roughness and wettability were measured. In vivo , zirconia coated implants were inserted in rabbit tibia and animals were respectively sacrificed at 2, 4, 8 and 12 weeks after implantation. The bond strength between implant and bone was measured by push-out test. The osseointegration was observed by scanning electron microscopy (SEM), micro CT and histological analyses. Quantified parameters including removal torque, and bone-implant contact (BIC) percentage were calculated. Results: The surface roughness (1.6 µm) and wettability (54.6°) of zirconia coated implant was more suitable than those of titanium implant (0.6 µm and 74.4°) for osseointegration. At 12 weeks, the push-out value of zirconia coated implant and titanium implant were (64.9±3.0) and (50.4±2.9) N, and BIC value of these two groups were (54.7±3.6)% and (41.5±3.6)%. All these differences had statistical significance. Conclusions: The surface characters of zirconia coated implant were more suitable for osseointegration and present better osseointegration than smooth titanium implant in vivo , especially at early stage.

  16. Dental implants modified with drug releasing titania nanotubes: therapeutic potential and developmental challenges.

    PubMed

    Gulati, Karan; Ivanovski, Sašo

    2017-08-01

    The transmucosal nature of dental implants presents a unique therapeutic challenge, requiring not only rapid establishment and subsequent maintenance of osseointegration, but also the formation of resilient soft tissue integration. Key challenges in achieving long-term success are sub-optimal bone integration in compromised bone conditions and impaired trans-mucosal tissue integration in the presence of a persistent oral microbial biofilm. These challenges can be targeted by employing a drug-releasing implant modification such as TiO 2 nanotubes (TNTs), engineered on titanium surfaces via electrochemical anodization. Areas covered: This review focuses on applications of TNT-based dental implants towards achieving optimal therapeutic efficacy. Firstly, the functions of TNT implants will be explored in terms of their influence on osseointegration, soft tissue integration and immunomodulation. Secondly, the developmental challenges associated with such implants are reviewed including sterilization, stability and toxicity. Expert opinion: The potential of TNTs is yet to be fully explored in the context of the complex oral environment, including appropriate modulation of alveolar bone healing, immune-inflammatory processes, and soft tissue responses. Besides long-term in vivo assessment under masticatory loading conditions, investigating drug-release profiles in vivo and addressing various technical challenges are required to bridge the gap between research and clinical dentistry.

  17. Photodynamic therapy to treat periimplantitis.

    PubMed

    Bombeccari, Gian Paolo; Guzzi, Gianpaolo; Gualini, Federico; Gualini, Sara; Santoro, Franco; Spadari, Francesco

    2013-12-01

    : Periimplantitis is a bacterial complication after dental implants implantation. Photodynamic therapy (PDT) implies the use of low-power laser in combination with appropriate photosensitizer to increase the detoxification of the implant surfaces. Little information exists about PDT in the treatment of periimplantitis. A randomized comparative case-control study has been conducted with 20 patients and 20 controls to compare the efficacy of antimicrobial PDT versus surgical therapy in patients with periimplantitis, who have received dental implants with rough surfaces. In the surgery group, mucoperiosteal flap surgery was used with scaling on implant surfaces and debridement of granulation tissue. Microbiologic testing was evaluated before and after intervention treatment, at 12 and 24 weeks in the study subjects. Total anaerobic counts of bacteria did not differ significantly between patients assigned to receive PDT and those assigned to receive surgical therapy (mean, 95.2% and 80.85%, respectively). PDT was associated with a significant decrease in bleeding scores (P = 0.02) as well as inflammatory exudation (P = 0.001). Treatment with PDT in patients with periimplantitis was not associated with major reduction of total anaerobic bacteria on the rough surfaces of dental implants as compared with surgical therapy. A significantly lower proinflammatory index of periimplantitis was observed in the PDT group at 24 weeks of follow-up.

  18. Soft tissue wound healing around teeth and dental implants.

    PubMed

    Sculean, Anton; Gruber, Reinhard; Bosshardt, Dieter D

    2014-04-01

    To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Resolution, sensitivity, and in vivo application of high-resolution computed tomography for titanium-coated polymethyl methacrylate (PMMA) dental implants.

    PubMed

    Cuijpers, Vincent M J I; Jaroszewicz, Jacub; Anil, Sukumaran; Al Farraj Aldosari, Abdullah; Walboomers, X Frank; Jansen, John A

    2014-03-01

    The aims of this study were (i) to determine the spatial resolution and sensitivity of micro- versus nano-computed tomography (CT) techniques and (ii) to validate micro- versus nano-CT in a dog dental implant model, comparative to histological analysis. To determine spatial resolution and sensitivity, standardized reference samples containing standardized nano- and microspheres were prepared in polymer and ceramic matrices. Thereafter, 10 titanium-coated polymer dental implants (3.2 mm in Ø by 4 mm in length) were placed in the mandible of Beagle dogs. Both micro- and nano-CT, as well as histological analyses, were performed. The reference samples confirmed the high resolution of the nano-CT system, which was capable of revealing sub-micron structures embedded in radiodense matrices. The dog implantation study and subsequent statistical analysis showed equal values for bone area and bone-implant contact measurements between micro-CT and histology. However, because of the limited sample size and field of view, nano-CT was not rendering reliable data representative of the entire bone-implant specimen. Micro-CT analysis is an efficient tool to quantitate bone healing parameters at the bone-implant interface, especially when using titanium-coated PMMA implants. Nano-CT is not suitable for such quantification, but reveals complementary morphological information rivaling histology, yet with the advantage of a 3D visualization. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  20. Accuracy of a new elastomeric impression material for complete-arch dental implant impressions.

    PubMed

    Baig, Mirza R; Buzayan, Muaiyed M; Yunus, Norsiah

    2018-05-01

    The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts. Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05. The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05). The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions. © 2018 John Wiley & Sons Australia, Ltd.

  1. Engineered Protein Coatings to Improve the Osseointegration of Dental and Orthopaedic Implants

    PubMed Central

    Raphel, Jordan; Karlsson, Johan; Galli, Silvia; Wennerberg, Ann; Lindsay, Christopher; Haugh, Matthew; Pajarinen, Jukka; Goodman, Stuart B.; Jimbo, Ryo; Andersson, Martin; Heilshorn, Sarah C.

    2016-01-01

    Here we present the design of an engineered, elastin-like protein (ELP) that is chemically modified to enable stable coatings on the surfaces of titanium-based dental and orthopaedic implants by novel photocrosslinking and solution processing steps. The ELP includes an extended RGD sequence to confer bio-signaling and an elastin-like sequence for mechanical stability. ELP thin films were fabricated on cp-Ti and Ti6Al4V surfaces using scalable spin and dip coating processes with photoactive covalent crosslinking through a carbene insertion mechanism. The coatings withstood procedures mimicking dental screw and hip replacement stem implantations, a key metric for clinical translation. They promoted rapid adhesion of MG63 osteoblast-like cells, with over 80% adhesion after 24 hours, compared to 38% adhesion on uncoated Ti6Al4V. MG63 cells produced significantly more mineralization on ELP coatings compared to uncoated Ti6Al4V. Human bone marrow mesenchymal stem cells (hMSCs) had an earlier increase in alkaline phosphatase activity, indicating more rapid osteogenic differentiation and mineral deposition on adhesive ELP coatings. Rat tibia and femur in vivo studies demonstrated that cell-adhesive ELP-coated implants increased bone-implant contact area and interfacial strength after one week. These results suggest that ELP coatings withstand surgical implantation and promote rapid osseointegration, enabling earlier implant loading and potentially preventing micromotion that leads to aseptic loosening and premature implant failure. PMID:26790146

  2. Biology of teeth and implants: Host factors - pathology, regeneration, and the role of stem cells.

    PubMed

    Eggert, F-Michael; Levin, Liran

    2018-01-01

    In chronic periodontitis and peri-implantitis, cells of the innate and adaptive immune systems are involved directly in the lesions within the tissues of the patient. Absence of a periodontal ligament around implants does not prevent a biologic process similar to that of periodontitis from affecting osseointegration. Our first focus is on factors in the biology of individuals that are responsible for the susceptibility of such individuals to chronic periodontitis and to peri-implantitis. Genetic factors are of significant importance in susceptibility to these diseases. Genetic factors of the host affect the composition of the oral microbiome in the same manner that they influence other microbiomes, such as those of the intestines and of the lungs. Our second focus is on the central role of stem cells in tissue regeneration, in the functioning of innate and adaptive immune systems, and in metabolism of bone. Epithelial cell rests of Malassez (ERM) are stem cells of epithelial origin that maintain the periodontal ligament as well as the cementum and alveolar bone associated with the ligament. The tissue niche within which ERM are found extends into the supracrestal areas of collagen fiber-containing tissues of the gingivae above the bony alveolar crest. Maintenance and regeneration of all periodontal tissues involves the activity of a variety of stem cells. The success of dental implants indicates that important groups of stem cells in the periodontium are active to enable that biologic success. Successful replantation of avulsed teeth and auto-transplantation of teeth is comparable to placing dental implants, and so must also involve periodontal stem cells. Biology of teeth and biology of implants represents the biology of the various stem cells that inhabit specialized niches within the periodontal tissues. Diverse biologic processes must function together successfully to maintain periodontal health. Osseointegration of dental implants does not involve formation of cementum or collagen fibers inserted into cementum - indicating that some stem cells are not active around dental implants or their niches are not available. Investigation of these similarities and differences between teeth and implants will help to develop a better understanding of the biology and physiologic functioning of the periodontium.

  3. 3D printing in dentistry.

    PubMed

    Dawood, A; Marti Marti, B; Sauret-Jackson, V; Darwood, A

    2015-12-01

    3D printing has been hailed as a disruptive technology which will change manufacturing. Used in aerospace, defence, art and design, 3D printing is becoming a subject of great interest in surgery. The technology has a particular resonance with dentistry, and with advances in 3D imaging and modelling technologies such as cone beam computed tomography and intraoral scanning, and with the relatively long history of the use of CAD CAM technologies in dentistry, it will become of increasing importance. Uses of 3D printing include the production of drill guides for dental implants, the production of physical models for prosthodontics, orthodontics and surgery, the manufacture of dental, craniomaxillofacial and orthopaedic implants, and the fabrication of copings and frameworks for implant and dental restorations. This paper reviews the types of 3D printing technologies available and their various applications in dentistry and in maxillofacial surgery.

  4. An Ex Vivo Model in Human Femoral Heads for Histopathological Study and Resonance Frequency Analysis of Dental Implant Primary Stability

    PubMed Central

    Hernández-Cortés, Pedro; Galindo-Moreno, Pablo; Catena, Andrés; Ortega-Oller, Inmaculada; Salas-Pérez, José; Gómez-Sánchez, Rafael; Aguilar, Mariano; Aguilar, David

    2014-01-01

    Objective. This study was designed to explore relationships of resonance frequency analysis (RFA)—assessed implant stability (ISQ values) with bone morphometric parameters and bone quality in an ex vivo model of dental implants placed in human femoral heads and to evaluate the usefulness of this model for dental implant studies. Material and Methods. This ex vivo study included femoral heads from 17 patients undergoing surgery for femoral neck fracture due to osteoporosis (OP) (n = 7) or for total prosthesis joint replacement due to severe hip osteoarthrosis (OA) (n = 10). Sixty 4.5 × 13 mm Dentsply Astra implants were placed, followed by RFA. CD44 immunohistochemical analysis for osteocytes was also carried out. Results. As expected, the analysis yielded significant effects of femoral head type (OA versus OA) (P < 0.001), but not of the implants (P = 0.455) or of the interaction of the two factors (P = 0.848). Bonferroni post hoc comparisons showed a lower mean ISQ for implants in decalcified (50.33 ± 2.92) heads than in fresh (66.93 ± 1.10) or fixated (70.77 ± 1.32) heads (both P < 0.001). The ISQ score (fresh) was significantly higher for those in OA (73.52 ± 1.92) versus OP (67.13 ± 1.09) heads. However, mixed linear analysis showed no significant association between ISQ scores and morphologic or histomorphometric results (P > 0.5 in all cases), and no significant differences in ISQ values were found as a function of the length or area of the cortical layer (both P > 0.08). Conclusion. Although RFA-determined ISQ values are not correlated with morphometric parameters, they can discriminate bone quality (OP versus OA). This ex vivo model is useful for dental implant studies. PMID:24995307

  5. Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs.

    PubMed

    Delgado-Ruiz, Rafael Arcesio; Marković, Aleksa; Calvo-Guirado, José Luís; Lazić, Zoran; Piattelli, Adriano; Boticelli, Daniele; Maté-Sánchez, José Eduardo; Negri, Bruno; Ramírez-Fernández, María Piedad; Mišić, Tijana

    2014-05-01

    The modification of implant surfaces could affect mechanical implant stability as well as dynamics and quality of peri-implant bone healing. The aim of this 3-month experimental study in dogs was to investigate implant stability, marginal bone levels and bone tissue response to zirconia dental implants with two laser-micro-grooved intraosseous surfaces in comparison with nongrooved sandblasted zirconia and sandblasted, high-temperature etched titanium implants. Implant surface characterization was performed using optical interferometric profilometty and energy dispersive X-ray spectroscopy. A total of 96 implants (4 mm in diameter and 10 mm in length) were inserted randomly in both sides of the lower jaw of 12 Fox Hound dogs divided into groups of 24 each: the control (titanium), the group A (sandblasted zirconia), the group B (sandolasted zirconia plus microgrooved neck) and the group C (sandblasted zirconia plus all microgrooved). All the implants were immediately loaded. Insertion torque, periotest values, radiographic crestal bone level and removal torque were recorded during the 3-month follow-up. Qualitative scanning electon microscope (SEM) analysis of the bone-implant interfaces of each group was performed. Insertion torque values were higher in the group C and control implants (p < 0.05). Periotest values increased in all the periods in proportion to the extent of microgrooving as follows: the group C > the control > the group B > the group A (p < 0.05). Radiographic measurements showed minimal crestal bone loss at 3 months for microgrooved zirconia implants (groups C and B) and control implants compared with the group A implants (p < 0.05). The removal torque values increased with time for all the groups as follows: the group C > the control > the group B > the group A (p < 0.05). SEM showed that implant surfaces of the groups B and C had an extra bone growth inside the microgrooves that corresponded to the shape and direction of the microgrooves. The addition of microgrooves to the entire intraosseous surface of zirconia dental implants enhances primary and secondary implant stability, promotes bone tissue ingrowth and preserves crestal bone levels.

  6. 75 FR 81618 - Request for Notification From Consumer Organizations Interested in Participating in the Selection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-28

    .... Knowledgeable in the areas of dental implants, dental materials, periodontology, tissue engineering, and dental... and tissue based products, regenerative medicine and combination products. Blood Products..., immunology, blood banking, surgery, internal medicine, biochemistry, engineering, biological and physical...

  7. Intraoral Digital Impressioning for Dental Implant Restorations Versus Traditional Implant Impression Techniques.

    PubMed

    Wilk, Brian L

    2015-01-01

    Over the course of the past two to three decades, intraoral digital impression systems have gained acceptance due to high accuracy and ease of use as they have been incorporated into the fabrication of dental implant restorations. The use of intraoral digital impressions enables the clinician to produce accurate restorations without the unpleasant aspects of traditional impression materials and techniques. This article discusses the various types of digital impression systems and their accuracy compared to traditional impression techniques. The cost, time, and patient satisfaction components of both techniques will also be reviewed.

  8. Intramaxillary and intermaxillary absolute anchorage with an endosseous dental implant and rare-earth magnets.

    PubMed

    Uribe, Flavio; Nanda, Ravindra

    2009-07-01

    This case report describes the management of a partially edentulous adult with a severe deepbite malocclusion and a collapsed buccal segment because of supraeruption of the maxillary second and third molars. The treatment involved placement of an endosseous dental implant to achieve absolute intermaxillary and intramaxillary anchorage. Rare-earth magnets embedded in acrylic bite-blocks were used to intrude the supraerupted maxillary molars on the right side. After use as an anchorage device, the implant was restored and brought into occlusion. Good occlusal and esthetic results were achieved with this cost-effective treatment.

  9. Electrochemical removal of biofilms from titanium dental implant surfaces.

    PubMed

    Schneider, Sebastian; Rudolph, Michael; Bause, Vanessa; Terfort, Andreas

    2018-06-01

    The infection of dental implants may cause severe inflammation of tissue and even bone degradation if not treated. For titanium implants, a new, minimally invasive approach is the electrochemical removal of the biofilms including the disinfection of the metal surface. In this project, several parameters, such as electrode potentials and electrolyte compositions, were varied to understand the underlying mechanisms. Optimal electrolytes contained iodide as well as lactic acid. Electrochemical experiments, such as cyclic voltammetry or measurements of open circuit potentials, were performed in different cell set-ups to distinguish between different possible reactions. At the applied potentials of E < -1.4 V, the hydrogen evolution reaction dominated at the implant surface, effectively lifting off the bacterial films. In addition, several disinfecting species are formed at the anode, such as triiodide and hydrogen peroxide. Ex situ tests with model biofilms of E. coli clearly demonstrated the effectiveness of the respective anolytes in killing the bacteria, as determined by the LIVE/DEAD™ assay. Using optimized electrolysis parameters of 30 s at 7.0 V and 300 mA, a 14-day old wildtype biofilm could be completely removed from dental implants in vitro. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review.

    PubMed

    Matusiewicz, Henryk

    2014-06-01

    Metal ion release from metallic materials, e.g. metallic alloys and pure metals, implanted into the human body in dental and orthopedic surgery is becoming a major cause for concern. This review briefly provides an overview of both metallic alloys and pure metals used in implant materials in dental and orthopedic surgery. Additionally, a short section is dedicated to important biomaterials and their corrosive behavior in both real solutions and various types of media that model human biological fluids and tissues. The present review gives an overview of analytical methods, techniques and different approaches applied to the measurement of in vivo trace metals released into body fluids and tissues from patients carrying metal-on-metal prostheses and metal dental implants. Reference levels of ion concentrations in body fluids and tissues that have been determined by a host of studies are compiled, reviewed and presented in this paper. Finally, a collection of published clinical data on in vivo released trace metals from metallic medical implants is included. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Self-Assembled Monolayers for Dental Implants

    PubMed Central

    Correa-Uribe, Alejandra

    2018-01-01

    Implant-based therapy is a mature approach to recover the health conditions of patients affected by edentulism. Thousands of dental implants are placed each year since their introduction in the 80s. However, implantology faces challenges that require more research strategies such as new support therapies for a world population with a continuous increase of life expectancy, to control periodontal status and new bioactive surfaces for implants. The present review is focused on self-assembled monolayers (SAMs) for dental implant materials as a nanoscale-processing approach to modify titanium surfaces. SAMs represent an easy, accurate, and precise approach to modify surface properties. These are stable, well-defined, and well-organized organic structures that allow to control the chemical properties of the interface at the molecular scale. The ability to control the composition and properties of SAMs precisely through synthesis (i.e., the synthetic chemistry of organic compounds with a wide range of functional groups is well established and in general very simple, being commercially available), combined with the simple methods to pattern their functional groups on complex geometry appliances, makes them a good system for fundamental studies regarding the interaction between surfaces, proteins, and cells, as well as to engineering surfaces in order to develop new biomaterials. PMID:29552036

  12. Tooth Loss and Dental Implant Outcomes - where is dentistry going? A Survey by SIdP, the Italian Society of Periodontology and Implantology.

    PubMed

    Cairo, Francesco; Landi, Luca; Gatti, Claudio; Rasperini, Giulio; Aimetti, Mario

    2018-05-22

    Recently, the Italian Society of Periodontology and Implantology (SIdP) committed an extensive survey to evaluate tooth loss and actual success of dental implants in the population. We would share the main outcomes with the present letter. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Functional Tooth Restoration by Allogeneic Mesenchymal Stem Cell-Based Bio-Root Regeneration in Swine

    PubMed Central

    Wei, Fulan; Song, Tieli; Ding, Gang; Xu, Junji; Liu, Yi; Liu, Dayong; Fan, Zhipeng; Zhang, Chunmei

    2013-01-01

    Our previous proof-of-concept study showed the feasibility of regenerating the dental stem cell-based bioengineered tooth root (bio-root) structure in a large animal model. Here, we used allogeneic dental mesenchymal stem cells to regenerate bio-root, and then installed a crown on the bio-root to restore tooth function. A root shape hydroxyapatite tricalcium phosphate scaffold containing dental pulp stem cells was covered by a Vc-induced periodontal ligament stem cell sheet and implanted into a newly generated jaw bone implant socket. Six months after implantation, a prefabricated porcelain crown was cemented to the implant and subjected to tooth function. Clinical, radiological, histological, ultrastructural, systemic immunological evaluations and mechanical properties were analyzed for dynamic changes in the bio-root structure. The regenerated bio-root exhibited characteristics of a normal tooth after 6 months of use, including dentinal tubule-like and functional periodontal ligament-like structures. No immunological response to the bio-roots was observed. We developed a standard stem cell procedure for bio-root regeneration to restore adult tooth function. This study is the first to successfully regenerate a functional bio-root structure for artificial crown restoration by using allogeneic dental stem cells and Vc-induced cell sheet, and assess the recipient immune response in a preclinical model. PMID:23363023

  14. A Review on the Wettability of Dental Implant Surfaces II: Biological and Clinical Aspects

    PubMed Central

    Gittens, Rolando A.; Scheideler, Lutz; Rupp, Frank; Hyzy, Sharon L.; Geis-Gerstorfer, Jürgen; Schwartz, Zvi; Boyan, Barbara D.

    2014-01-01

    Dental and orthopaedic implants have been under continuous advancement to improve their interactions with bone and ensure a successful outcome for patients. Surface characteristics such as surface topography and surface chemistry can serve as design tools to enhance the biological response around the implant, with in vitro, in vivo and clinical studies confirming their effects. However, the comprehensive design of implants to promote early and long-term osseointegration requires a better understanding of the role of surface wettability and the mechanisms by which it affects the surrounding biological environment. This review provides a general overview of the available information about the contact angle values of experimental and of marketed implant surfaces, some of the techniques used to modify surface wettability of implants, and results from in vitro and clinical studies. We aim to expand the current understanding on the role of wettability of metallic implants at their interface with blood and the biological milieu, as well as with bacteria, and hard and soft tissues. PMID:24709541

  15. Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process.

    PubMed

    Shahidi, Shoaleh; Zamiri, Barbad; Abolvardi, Masoud; Akhlaghian, Marzieh; Paknahad, Maryam

    2018-06-01

    Accurate measurement of the available bone height is an essential step in the pre-surgical phase of dental implantation. Panoramic radiography is a unique technique in the pre-surgical phase of dental implantations because of its low cost, relatively low-dose, and availability. This article aimed to assess the reliability of dental panoramic radiographs in the accurate measurement of the vertical bone height with respect to the horizontal location of the alveolar crest. 132 cone-beam computed tomography (CBCT) of the edentulous mandibular molar area and dental panoramic radiograph of 508 patients were selected. Exclusion criteria were bone abnormalities and detectable ideal information on each modality. The alveolar ridge morphology was categorized into 7 types according to the relative horizontal location of the alveolar crest to the mandibular canal based on CBCT findings. The available bone height (ABH) was defined as the distance between the upper border of the mandibular canal and alveolar crest. One oral radiologist and one oral surgeon measured the available bone height twice on each modality with a 7-dayinterval. We found a significant correlation between dental panoramic radiographs and cone-beam computed tomography values (ICC=0.992, p < 0.001). A positive correlation between the horizontal distance of the alveolar crest to the mandibular canal and measured differences between two radiographic modalities had been found (r=0.755, p < 0.001). For each single unit of increase in the horizontal distance of the alveolar crest to the mandibular canal, dental panoramic radiographs showed 0.87 unit of overestimation ( p < 0.001). Dental panoramic radiographs can be employed safely in the pre-surgical phase of dental implantation in posterior alveolus of mandible, especially in routine and simple cases.

  16. Effect of lubricant on the reliability of dental implant abutment screw joint: An in vitro laboratory and three-dimension finite element analysis.

    PubMed

    Wu, Tingting; Fan, Hongyi; Ma, Ruiyang; Chen, Hongyu; Li, Zhi; Yu, Haiyang

    2017-06-01

    Biomechanical factors play a key role in the success of dental implants. Fracture and loosening of abutment screws are major issues. This study investigated the effect of lubricants on the stability of dental implant-abutment connection. As lubricants, graphite and vaseline were coated on the abutment screw surface, respectively, and a blank without lubricant served as the control. The total friction coefficient (μ tot ), clamping force, fatigue behavior and detorque of the joint combined with dynamic cyclic loading were measured under different lubricating conditions. Further, a three-dimensional finite element analysis was used to investigate stress distribution, in conjunction with experimental images. The results showed that the lubricant reduced μ tot , which in turn led to an increase in clamping force. Decrease in loading increased the fatigue life of the screw. However, use of lubricant at high load reduced the fatigue life. Ductile fracture at the first thread of the screw was the chief failure mode, which was due to maximum von Mises stress. Higher stress levels occurred in the lubricant groups. Lubricated screws resulted in lower detorque which made the joint easier to loosen. In conclusion, the lubricant cannot effectively improve the reliability of dental implant-abutment connection. Keeping the interfaces of implant-screw uncontaminated and strengthening the surface of the screw may be recommend for clinical operation and future design. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Effect of recombinant human bone morphogenetic protein-2 on bone regeneration and osseointegration of dental implants.

    PubMed

    Sykaras, N; Triplett, R G; Nunn, M E; Iacopino, A M; Opperman, L A

    2001-08-01

    Recombinant human bone morphogenetic protein-2 (rhBMP-2) induced bone regeneration and osseointegration was evaluated in bony defects created within the hollow chamber of endosseous dental implants in 14 foxhound dogs. Bilateral extractions of mandibular premolars were performed and surgical implantation of 104 hollow cylinder implants followed after 8 weeks of healing. Experimental implants had their hollow chamber filled with 20 microg of rhBMP-2 delivered with a bovine collagen carrier, whereas the control implants had their apical chamber left empty. Dogs were followed for 2, 4, 8 and 12 weeks. Histomorphometric evaluation and immunohistochemical analysis were performed. Minimal bone was regenerated at 2 weeks for both groups. At 4 weeks, bone fill averaged 23.48% for the rhBMP-2 and 5.98% for the control group (P<0.05). At 8 weeks, mean bone fill was 20.94% and 7.75% for the rhBMP-2 and the controls, respectively (P<0.05). At 12 weeks, mean bone fill was 31.39% and 24.31% for the rhBMP-2 and control implants, respectively (P>0.05). Bone-implant contact (BIC) increased for both groups over time and at 8 weeks the rhBMP-2 BIC value was 18.65% and for the control 7.22% (P<0.05). At 12 weeks, the BIC was 43.78% and 21.05% for the rhBMP-2 and the control group, respectively (P<0.05). Immunohistochemical staining for type II collagen was positive only for parts of the collagen carrier and formation of cartilaginous intermediate was not observed in any of the specimens. The results suggest that, in confined defects adjacent to dental implants, rhBMP-2 can induce bone regeneration in close apposition to the implant surface.

  18. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses.

    PubMed

    Minatel, Lurian; Verri, Fellippo Ramos; Kudo, Guilherme Abu Halawa; de Faria Almeida, Daniel Augusto; de Souza Batista, Victor Eduardo; Lemos, Cleidiel Aparecido Araujo; Pellizzer, Eduardo Piza; Santiago, Joel Ferreira

    2017-02-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P<0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P<0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Three-Dimensional Nonlinear Finite Element Analysis and Microcomputed Tomography Evaluation of Microgap Formation in a Dental Implant Under Oblique Loading.

    PubMed

    Jörn, Daniela; Kohorst, Philipp; Besdo, Silke; Borchers, Lothar; Stiesch, Meike

    2016-01-01

    Since bacterial leakage along the implant-abutment interface may be responsible for peri-implant infections, a realistic estimation of the interface gap width during function is important for risk assessment. The purpose of this study was to compare two methods for investigating microgap formation in a loaded dental implant, namely, microcomputed tomography (micro-CT) and three-dimensional (3D) nonlinear finite element analysis (FEA); additionally, stresses to be expected during loading were also evaluated by FEA. An implant-abutment complex was inspected for microgaps between the abutment and implant in a micro-CT scanner under an oblique load of 200 N. A numerical model of the situation was constructed; boundary conditions and external load were defined according to the experiment. The model was refined stepwise until its load-displacement behavior corresponded sufficiently to data from previous load experiments. FEA of the final, validated model was used to determine microgap widths. These were compared with the widths as measured in micro-CT inspection. Finally, stress distributions were evaluated in selected regions. No microgaps wider than 13 μm could be detected by micro-CT for the loaded implant. FEA revealed gap widths up to 10 μm between the implant and abutment at the side of load application. Furthermore, FEA predicted plastic deformation in a limited area at the implant collar. FEA proved to be an adequate method for studying microgap formation in dental implant-abutment complexes. FEA is not limited in gap width resolution as are radiologic techniques and can also provide insight into stress distributions within the loaded complex.

  20. Simulation of peri-implant bone healing due to immediate loading in dental implant treatments.

    PubMed

    Chou, Hsuan-Yu; Müftü, Sinan

    2013-03-15

    The goal of this work was to investigate the role of immediate loading on the peri-implant bone healing in dental implant treatments. A mechano-regulatory tissue differentiation model that takes into account the stimuli through the solid and the fluid components of the healing tissue, and the diffusion of pluripotent stem cells into the healing callus was used. A two-dimensional axisymmetric model consisting of a dental implant, the healing callus tissue and the host bone tissue was constructed for the finite element analysis. Poroelastic material properties were assigned to the healing callus and the bone tissue. The effects of micro-motion, healing callus size, and implant thread design on the length of the bone-to-implant contact (BIC) and the bone volume (BV) formed in the healing callus were investigated. In general, the analysis predicted formation of a continuous layer of soft tissue along the faces of the implant which are parallel to the loading direction. This was predicted to be correlated with the high levels of distortional strain transferred through the solid component of the stimulus. It was also predicted that the external threads on the implant, redistribute the interfacial load, thus help reduce the high distortional stimulus and also help the cells to differentiate to bone tissue. In addition, the region underneath the implant apex was predicted to experience high fluid stimulus that results in the development of soft tissue. The relationship between the variables considered in this study and the outcome measures, BV and BIC, was found to be highly nonlinear. A three-way analysis of variance (ANOVA) of the results was conducted and it showed that micro-motion presents the largest hindrance to bone formation during healing. Copyright © 2013 Elsevier Ltd. All rights reserved.

Top