Sample records for denture soft lining

  1. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

    PubMed

    Lau, Mayank; Amarnath, G S; Muddugangadhar, B C; Swetha, M U; Das, Kopal Anshuraj Ashok Kumar

    2014-04-01

    The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each. Tensile and shear bond strength to the conventional heat cured acrylic denture base resin were examined by Instron Universal Tensile Testing Machine using the equation F=N/A (F-maximum force exerted on the specimen (Newton) and A-bonding area= 50.24 mm2). One-way ANOVA was used for multiple group comparisons followed by Bonferroni Test and Hsu's MCB for multiple pairwise comparisons to asses any significant differences between the groups. The highest mean Tensile bond strength value was obtained for Ufi Gel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01 MPa). The highest mean Shear bond strength value was obtained for Ufi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05 MPa). The Benferroni test showed a significant difference in the mean tensile bond strength and the mean shear bond strength when the two denture soft liners were compared as well as when the two denture hard liners were compared. Hsu's MCB implied that Ufi gel hard is better than its other closest competitors. The Tensile and Shear bond strength values of denture soft reliners were significantly lower than denture hard reliners. How to cite the article: Lau M, Amarnath GS, Muddugangadhar BC, Swetha MU, Das KA. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study. J Int Oral Health 2014;6(2):55-61.

  2. Long-Term Soft Denture Lining Materials

    PubMed Central

    Chladek, Grzegorz; Żmudzki, Jarosław; Kasperski, Jacek

    2014-01-01

    Long-term soft denture lining (LTSDL) materials are used to alleviate the trauma associated with wearing complete dentures. Despite their established clinical efficacy, the use of LTSDLs has been limited due to the unfavorable effects of the oral environment on some of their mechanical and performance characteristics. The unresolved issue of LTSDL colonization by Candida albicans is particularly problematic. Silicone-based LTSDL (SLTSDL) materials, which are characterized by more stable hardness, sorption and solubility than acrylic-based LTSDLs (ALTSDLs), are currently the most commonly used LTSDLs. However, SLTSDLs are more prone to debonding from the denture base. Moreover, due to their limitations, the available methods for determining bond strength do not fully reflect the actual stability of these materials under clinical conditions. SLTSDL materials exhibit favorable viscoelastic properties compared with ALTSDLs. Furthermore, all of the lining materials exhibit an aging solution-specific tendency toward discoloration, and the available cleansers are not fully effective and can alter the mechanical properties of LTSDLs. Future studies are needed to improve the microbiological resistance of LTSDLs, as well as some of their performance characteristics. PMID:28788163

  3. Effect of sealer coating and storage methods on the surface roughness of soft liners.

    PubMed

    Usta Kutlu, Ilknur; Yanikoğlu, Nuran Dinckal; Kul, Esra; Duymuş, Zeynep Yesïl; Sağsöz, Nurdan Polat

    2016-03-01

    A soft lining is applied under a removable prosthesis for various reasons. The porosity of the lining material may increase colonization by microorganisms and cause tissue inflammation. The purpose of this in vitro study was to evaluate the effect of sealer coating on the surface roughness of soft lining materials under 4 different conditions. A total of 125 specimens were prepared. One high-temperature silicone-based soft lining material and 2 room-temperature-polymerized soft lining materials (1 silicone-based and 1 methacrylate-based) were used. Twenty-five specimens of each room-temperature soft lining material were coated with 2 layers of surface sealer. Additionally, 5 specimens of each material were stored in either distilled water, Coca-Cola, denture cleanser, saliva, or air. The surface roughness was measured at baseline and after 1, 7, 14, and 28 days. Surface roughness values were analyzed with repeated measures analysis of variance, and the Bonferroni multiple comparison test was performed using time-dependent groups and storage methods. In the time-dependent groups, methacrylate-based sealer-coated soft liners exhibited a significant increase in roughness (1.74-2.09 μm, P<.001), and silicone-based sealer-coated soft liners exhibited a decrease in roughness, but it was not significant (2.16-2.02 μm, P>.05). Therefore, the sealer coating was not effective in reducing surface roughness. Among the time-dependent storage methods, the denture cleanser exhibited an almost significant increase in roughness (1.83-1.99 μm, P=.054). Coca-Cola and artificial saliva did not show a significant difference (P>.05). However, a significant decrease in roughness was found with distilled water (P=.02) and air (P<.001). Statistically significant differences in surface roughness were found among the different types of soft liners. The sealer coating had no significant effect, and denture cleanser slightly increased the surface roughness. Contrary to expectations, the roughness did not increase in all groups over time. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. The effect of accelerated ageing on colour stability of visible light-cured (VLC) chairside denture liners.

    PubMed

    Kostoulas, Ioannis; Polyzois, Gregory; Mitsoudis, Anastasios; Kavoura, Victoria; Frangou, Maria

    2012-06-01

    The purpose of this study was to assess the colour stability of seven visible light-cured (VLC) hard and soft denture liners by an in vitro accelerated ageing test and compare them with two autopolymerised hard and soft liners. Ten specimens of each material were fabricated. The initial colour was measured with a tri-stimulus colorimeter. One set of five specimens was placed in distilled water at 37°C in the dark for 15 days, while the remaining were subjected to UV/visible light-accelerated ageing initially for 24 h and then for 144 h. Colour change (ΔΕ) was calculated. Data were statistically analysed by anova, Tukey and t-tests at α = 0.05. All the liners showed clinically acceptable colour change (ΔΕ ≤ 6.8) in distilled water. The colour changes after ageing for Triad DuaLine, Lightdon U, Ufi Gel H and Light Liner Hard were clinically unacceptable (ΔΕ ≥ 6.8), whereas LightLiner Soft, Astron LC Soft, Triad Resiline and Flexacryl Soft presented slighter and clinically acceptable colour change (ΔΕ ≤ 6.8). Accelerated ageing affected significantly the colour stability of all denture liners tested except Astron LC Soft. Soft VLC denture liners were more colour-stable than hard VLC liners. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  5. Effect of the addition of antimicrobial agents on Shore A hardness and roughness of soft lining materials.

    PubMed

    Urban, Vanessa M; Lima, Thiago F; Bueno, Mirian G; Giannini, Marcelo; Arioli Filho, João N; de Almeida, Ana Lúcia P F; Neppelenbroek, Karin H

    2015-04-01

    While the incorporation of antimicrobial agents into soft denture liners has been suggested as a reliable alternative treatment for denture stomatitis, it may affect the liner's properties. The effect of addition of antimicrobial agents for the treatment of denture stomatitis on the surface roughness and Shore A hardness of soft lining materials was evaluated. The test groups comprised specimens (36 × 7 × 6 mm(3) ) of soft materials (Softone and Trusoft) without (control) or with incorporation of drugs (nystatin, miconazole, ketoconazole, chlorhexidine diacetate, and itraconazole). Hardness (Shore A) and roughness (Ra) were evaluated after immersion of specimens (n = 10) in distilled water at 37°C for 24 hours, 7 and 14 days. Data were analyzed by 3-way ANOVA/Tukey's test (α = 0.05). After 14 days, an increase (p < 0.05) was observed in the hardness of soft materials with time for the modified specimens, except for itraconazole. Addition of drugs increased the Softone roughness only for the addition of miconazole and chlorhexidine (p < 0.05), and did not increase the roughness of Trusoft with time. Only chlorhexidine and itraconazole altered the roughness compared to the control for each material (p < 0.05). The smallest changes of hardness and roughness with time in the modified groups compared to controls were observed for itraconazole groups for both materials. © 2014 by the American College of Prosthodontists.

  6. Mechanical properties of an experimental soft lining material based on urethane oligomer.

    PubMed

    Kanie, Takahito; Kadokawa, Akihiko; Arikawa, Hiroyuki; Fujii, Koichi; Ban, Seiji

    2005-09-01

    The purpose of this study was to investigate the apparent viscosities and mechanical properties of two experimental light-curing soft lining materials (SLM-1 and SLM-2) based on soft-type urethane oligomers, as well as the shear bond strength and dye penetration between the denture base resin and the polymerized SLMs after storage in water. The apparent viscosities of SLM-1 and SLM-2 were 144.0-146.9 and 1.9 Pa x s respectively. After storage in water for two prescribed periods (one day and three months), the mechanical properties of the SLMs on the overall were 10.6-20.6 MPa for elastic modulus, 69.3-72.1 for hardness, and 3.8-4.0 MPa for adhesive strength. Tensile strength was observed to decrease after three months' storage in water, when compared to that after one-day storage (p < 0.01). Water sorption rates also differed significantly (p < 0.05)--namely 3.0 and 2.8 mg/cm2 for SLM-1 after one day and three months respectively, and 2.0 and 2.2 mg/cm2 for SLM-2. As for dye penetration, no infiltration was observed at the denture base resin-SLM interface after three months' storage. Based on the results of this study, it seemed like the SLMs possess many suitable properties for use with a new technique that we recently developed for preparing denture base resin and soft lining material.

  7. Sorption, Solubility, Bond Strength and Hardness of Denture Soft Lining Incorporated with Silver Nanoparticles

    PubMed Central

    Chladek, Grzegorz; Kasperski, Jacek; Barszczewska-Rybarek, Izabela; Żmudzki, Jarosław

    2013-01-01

    The colonization of denture soft lining material by oral fungi can result in infections and stomatitis of oral tissues. In this study, 0 ppm to 200 ppm of silver nanoparticles was incorporated as an antimicrobial agent into composites to reduce the microbial colonization of lining materials. The effect of silver nanoparticle incorporation into a soft lining material on the sorption, solubility, hardness (on the Shore A scale) and tensile bond strength of the composites was investigated. The data were statistically analyzed using two-way ANOVA and Newman-Keuls post hoc tests or the chi-square Pearson test at the p < 0.05 level. An increase in the nanosilver concentration resulted in a decrease in hardness, an increase in sorption and solubility, a decrease in bond strength and a change in the failure type of the samples. The best combination of bond strength, sorption, solubility and hardness with antifungal efficacy was achieved for silver nanoparticle concentrations ranging from 20 ppm to 40 ppm. These composites did not show properties worse than those of the material without silver nanoparticles and exhibited enhanced in vitro antifungal efficiency. PMID:23271371

  8. Tensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatments.

    PubMed

    Akin, Hakan; Tugut, Faik; Guney, Umit; Kirmali, Omer; Akar, Turker

    2013-01-01

    This study evaluated the effect of various surface treatments on the tensile bond strength of a silicone-based soft denture liner to two chemically different denture base resins, heat-cured polymethyl methacrylate (PMMA), and light-activated urethane dimethacrylate or Eclipse denture base resin. PMMA test specimens were fabricated and relined with a silicone-based soft denture liner (group AC). Eclipse test specimens were prepared according to the manufacturer's recommendation. Before they were relined with a silicone-based soft denture liner, each received one of three surface treatments: untreated (control, group EC), Eclipse bonding agent applied (group EB), and laser-irradiated (group EL). Tensile bond strength tests (crosshead speed = 5 mm/min) were performed for all specimens, and the results were analyzed using the analysis of variance followed by Tukey's test (p = 0.05). Eclipse denture base and PMMA resins presented similar bond strengths to the silicone-based soft denture liner. The highest mean force was observed in group EL specimens, and the tensile bond strengths in group EL were significantly different (p < 0.05) from those in the other groups.

  9. Shore hardness and tensile bond strength of long-term soft denture lining materials.

    PubMed

    Kim, Bong-Jun; Yang, Hong-So; Chun, Min-Geoung; Park, Yeong-Joon

    2014-11-01

    Reduced softness and separation from the denture base are the most significant problems of long-term soft lining materials. The purpose of this study was to evaluate the durometer Shore A hardness and tensile bond strength of long-term soft denture lining materials and to investigate the correlation between these 2 properties. A group of 7 soft lining materials, 6 silicone based (Dentusil, GC Reline Soft, GC Reline Ultrasoft, Mucopren Soft, Mucosoft, Sofreliner Tough) and 1 acrylic resin based (Durabase), were evaluated for durometer Shore A hardness and tensile bond strength to heat-polymerized denture base resin (Lucitone 199). A specially designed split mold and loading assembly with a swivel connector were used for the durometer Shore A hardness test and tensile bond strength test to improve accuracy and facilitate measurement. Three specimens of each product were stored in a 37°C water bath, and durometer Shore A hardness tests were carried out after 24 hours and 28 days. A tensile bond strength test was carried out for 10 specimens of each product, which were stored in a 37°C water bath for 24 hours before the test. Repeated-measures ANOVA, the Kruskal-Wallis and Duncan multiple range tests, and the Spearman correlation were used for statistical analyses. The repeated-measures ANOVA found significant durometer Shore A hardness differences for the materials (P<.001) and the interaction effect (aging×materials) (P<.001). GC Reline Ultrasoft showed the lowest mean durometer Shore A hardness (21.30 ±0.29 for 24 hours, 34.73 ±0.47 for 28 days), and GC Reline Soft showed the highest mean durometer Shore A hardness (50.13 ±0.48 for 24 hours, 57.20 ±0.28 for 28 days). The Kruskal-Wallis test found a significant difference in the mean tensile bond strength values (P<.001). GC Reline Ultrasoft (0.82 ±0.32 MPa) and Mucopren Soft (0.96 ±0.46 MPa) had a significantly lower mean tensile bond strength (P<.05). GC Reline Soft had the highest mean tensile bond strength (2.99 ±0.43 MPa) (P<.05), and acrylic resin-based Durabase showed a significantly different tensile bond strength (1.32 ±0.16 MPa), except for Mucopren Soft, among the materials (P<.05). The tensile bond strength and Shore A hardness showed a statistically insignificant moderate positive correlation (r=0.571, P=.180 for Shore A hardness 24 hours versus tensile bond strength; r=0.607, P=.148 for Shore A hardness 28 days versus tensile bond strength). Within the limitations of this study, significant differences were found in durometer Shore A hardness (with aging time) and tensile bond strength among the materials. Adhesive failure was moderately correlated with durometer Shore A hardness, especially after 28 days, but was not significant. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. A comparative evaluation of effect on water sorption and solubility of a temporary soft denture liner material when stored either in distilled water, 5.25% sodium hypochlorite or artificial saliva: An in vitro study.

    PubMed

    Garg, Aditi; Shenoy, K Kamalakanth

    2016-01-01

    Soft denture liners have a key role in modern removable prosthodontics since they restore health to inflamed and abused mucosa by redistribution of forces transmitted to the edentulous ridges. The most common problems encountered using soft denture liners are water sorption and solubility when in contact with saliva or storage media. These problems are associated with swelling, distortion, support of Candida albicans growth, and stresses at the liner/denture base interface that reduces the bond strength. To evaluate the water sorption and solubility of commercially available acrylic based self cure soft denture lining material (GC RELINE™ Tissue Conditioner) after immersion in three different storage media (distilled water, Shellis artificial saliva, 5.25% sodium hypochlorite disinfectant solution) at time interval of 4, 7, 11, and 15 days. The study involved preparation of artificial saliva using Shellis formula. A total 45 standardized samples of the material (GC RELINE™) were prepared in disk form (15 mm in diameter and 2 mm in thickness). The study was divided into three groups with storage in Control (distilled water), Shellis artificial saliva, and 5.25% sodium hypochlorite. Samples were dried in a desiccator and weighed in the analytical balance to measure the initial weight (mg/cm2) of the disks (W1). The first groups (15 samples) were placed in 30 ml distilled water (Group A) at 37ºC, second group 30 ml of artificial saliva (Group B) and third group in 5.25% sodium hypochlorite (Group C). Disks were removed from disinfectant after 5 min and placed in 30 ml distilled water. On days 4, 7, 11, and 15, all samples were removed from their containers and reweighed to measure the weight (mg/cm2) of the disks after sorption (W2). The solubility was measured by placing the disks back in the desiccator after each sorption cycle and drying them to constant weight in the desiccator. These values were weight after desiccation (W3). Water sorption and solubility was calculated: 1. Sorption (mg/cm2) = (W2-W1)/Surface area 2. Solubility (mg/cm2) = (W1-W3)/Surface area. Statistical Analysis was done using one way analysis of variance and the intercomparison between each group was done using Tukey's honestly significance difference (HSD) test. Within the limitations of this study it was concluded that water sorption of the GC RELINE™ soft denture liner material was highest in distilled water followed by 5.25% sodium hypochlorite and least in Shellis artificial saliva at 4, 7, and 11 day interval. However, on the 15th day, the results showed maximum water sorption in 5.25% sodium hypochlorite followed by distilled water and least in artificial saliva. The results on solubility showed highest solubility of GC RELINE soft denture liner in artificial saliva followed by distilled water and least in 5.25% sodium hypochlorite at 4, 7, 11, and 15 day interval. The least water uptake of the soft liner in artificial saliva was due to its ionic properties and supports the theory that water uptake of these materials is osmotically driven. However, the solubility was highest in artificial saliva since it is a mix of various salts and other additives, so there is a possibility of interaction with soft denture lining material.

  11. The Windowed Removable Partial Denture: A Treatment Option for Patients with Lone-Standing Teeth.

    PubMed

    Jum'ah, Ahmad A; Haite, Terence; Nattress, Brian

    2015-03-01

    The decision as to whether to retain or extract a single remaining natural tooth prior to the provision of dentures can be a difficult one. If the tooth is left in situ, the development of an adequate peripheral seal around the denture is not possible thereby compromising the appliance' retention. If the tooth is extracted the possibility of gaining direct retention with the use of clasps or attachments is lost. This paper aims to illustrate the use of windowed removable partial denture design and review the literature relevant to this area. The use of such a design can enhance the retention of the appliance by encircling the lone standing tooth/teeth utilising an elastomeric permanent soft lining material.

  12. Evaluate the Effect of Commercially Available Denture Cleansers on Surface Hardness and Roughness of Denture Liners at Various Time Intervals

    PubMed Central

    Mohammed, Hilal S.; Singh, Sumeet; Hari, Prasad A.; Amarnath, G. S.; Kundapur, Vinaya; Pasha, Naveed; Anand, M.

    2016-01-01

    Background and objective: Chemical cleansing by denture cleansers is first choice for denture plaque control. The most common problems while using denture cleansers are hardening, porosity, odor sorption, water sorption, solubility, and colour change, bacterial and fungal growth. Chemical cleansing procedures have been found to have an effect on the physical and mechanical properties of denture liners. Thus, this study was conducted to evaluate the effect of commercially available denture cleansers on surface hardness and roughness of acrylic and silicon based denture liners at various time interval. Method: Two autopolymerising denture liners Kooliner (acrylic) and GC reline soft (silicon) were tested with two commercially available denture cleansers, polident and efferdent plus. Total of 120 specimens were prepared and all the specimens were divided into six groups based on the relining materials and denture cleansers used. Surface hardness and surface roughness was tested using Shore A durometer and profilometer respectively at the end of day 1, day 7, day 30 and day 90. All the specimens were stored in artificial saliva throughout the study. Cleanser solution was prepared daily by adding Polident and Efferdent plus denture cleanser tablet into 250ml of enough very warm (not hot) water. Acrylic and silicon liner groups were cleansed in a solution of denture cleanser and water for 15 minutes daily, rinsed with water and stored in artificial saliva at room temperature. The data was analyzed with one way ANOVA and independent t-test. Result: The acrylic soft lining showed gradual hardening and increase in surface roughness after immersion in denture cleanser and also with time. Acrylic liner material showed maximum hardness and roughness with Polident followed by Efferdent plus and water (control group). Silicone lining material showed a slight difference in hardness and roughness between the test group and control group. There was a slight increase in hardness in all the groups with time. Very slight increase in mean surface roughness of all the silicon liner groups from day 1 to day 90 was observed. A statistically significant change was noted between and within the all silicon liner groups on day 7, day 30 and day 90. Conclusion: The average surface hardness and surface roughness were lower in silicon liner material than acrylic liner material. Maximum surface roughness was noted by Polident followed by Efferdent Plus and Water for both acrylic liner group and silicon liner group. PMID:28190983

  13. Effect of beverages on the hardness and tensile bond strength of temporary acrylic soft liners to acrylic resin denture base.

    PubMed

    Safari, A; Vojdani, M; Mogharrabi, S; Iraji Nasrabadi, N; Derafshi, R

    2013-12-01

    Two potential problems commonly identified with a denture base incorporating a resilient liner are failure of the bond between acrylic resin and soft liner material, and loss of resiliency of the soft liner over time. Since patients may drink different beverages, it is important to evaluate their effects on physical properties of soft lining materials. The objective of this in vitro study was to evaluate the effect of different beverages on the hardness of two temporary acrylic-based soft lining materials and their bond strength to the denture base resin. For the hardness test; a total of 80 rectangular specimens (40mm×10mm×3mm) were fabricated from a heat-polymerized polymethylmethacrylate. Two commercially auto-polymerized acrylic resin-based resilient liners; Coe-Soft and Visco-gel were prepared according to the manufacturers' instructions and applied on the specimens. For the tensile test, 160 cylindrical specimens (30mm×10mm) were prepared. The liners were added between specimens with a thickness of 3 mm. The specimens of both soft liners were divided into 4 groups (n=10) and immersed in distilled water as the control group, Coca-Cola, 8% and 50% ethanol. All groups were stored in separate containers at 37(o)C for 12 days. All beverages were changed daily. The hardness was determined using a Shore A durometer and tensile bond strength was determined in a ZwickRoell testing machine at a cross-head speed of 5mm/min. The results were analyzed using two-way ANOVA. There was no significant interaction between the soft liners and the drinks for both hardness (p= 0.748) and bond strength (p= 0.902). There were statistically significant differences between all drinks for both hardness (p< 0.001) and bond strength (p< 0.05). Within the limitations of this study, it seems that drinking Coca-Cola and alcoholic beverages would not be potentially causing any problems for the temporary acrylic soft liners.

  14. Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.

    PubMed

    Ashmawy, Tarek Mohy; El Talawy, Dina Bahgat; Shaheen, Nasser Hussein

    2014-09-01

    To objectively evaluate the effect of mini-implant- supported mandibular overdentures on electromyographic activity (EMG) of the masseter muscle during chewing of hard and soft foods. Twelve completely edentulous patients (4 females and 8 males) with maladaptive experience of wearing mandibular dentures received new maxillary and mandibular dentures. After 3 months of adaptation, four mini dental implants (MDIs) were inserted in the interforaminal region of the mandible, and the new mandibular dentures were connected to the implants immediately with O/ring attachments. The activity of masseter muscle (EMG) and the duration of chewing cycle were measured during chewing hard (carrot) and soft (gum) foods. The measurements were made 3 months after wearing each of the following prostheses: the new conventional dentures; and the MDI-retained mandibular overdentures. The EMG of masseter muscle increased and the DC decreased with MDI-retained mandibular overdentures when compared to conventional dentures. Hard food (carrot) was associated with increased EMG and decreased DC when compared to soft food (gum) for both conventional dentures and MDI-retained mandibular overdentures. Mini-implant-supported mandibular overdentures are associated with increased activity of masseter muscle and decreased duration of chewing cycle for both hard and soft foods when compared to conventional dentures.

  15. Tensile Bond Strength between Soft Liners and Two Chemically Different Denture Base Materials: Effect of Thermocycling.

    PubMed

    Tugut, Faik; Coskun, Mehmet Emre; Dogan, Derya Ozdemir; Kirmali, Omer; Akin, Hakan

    2016-06-01

    The bond strength of soft denture liner to a recently introduced denture base resin after thermocycling has not been compared to traditional denture base materials. The objective of this study was to investigate the effects of thermocycling on the tensile bond strength of soft denture liners to two chemically different denture base resins, polymethyl methacrylate (PMMA) and urethane dimethacrylate (UDMA). A total of 48 PMMA and UDMA tensile test specimens were fabricated by attaching two different soft denture liners (Molloplast-B, Permaflex) according to the manufacturers' instructions and assigned to two groups. Half of the specimens for each group were stored in water for 1 week, and the other half were thermocycled (5000 cycles) between baths of 5°C and 55°C. Specimens were mounted on a universal testing machine with a 5 mm/min crosshead speed. The data were analyzed with three-way ANOVA and post hoc Tukey-Kramer multiple comparisons tests (α = 0.05). The highest bond strength was measured in the specimens from the UDMA/Molloplast groups, and the lowest was seen in the PMMA/Permaflex group. No significant difference in bond strength was detected in PMMA/Permaflex groups after thermocycling (p = 0.082), whereas other groups exhibited significant differences after thermocycling (p < 0.05). Thermocycling decreased the bond strength values in both the PMMA and UDMA groups. Regardless of types of soft liners, PMMA specimens presented lower bond strength values than UDMA specimens, both before and after thermocycling. © 2015 by the American College of Prosthodontists.

  16. Effect of Silver-Emitting Filler on Antimicrobial and Mechanical Properties of Soft Denture Lining Material

    PubMed Central

    Jabłońska-Stencel, Ewa; Pakieła, Wojciech; Mertas, Anna; Bobela, Elżbieta; Kasperski, Jacek; Chladek, Grzegorz

    2018-01-01

    Colonization of silicone-based soft lining materials by pathogenic yeast-type fungi is a common problem associated with the use of dentures. In this study, silver sodium hydrogen zirconium phosphate (SSHZP) was introduced into polydimethylsiloxane-based material as an antimicrobial filler at concentrations of 0.25, 0.5, 1, 2, 4, 6, 8, 10, 12, and 14% (w/w). The in vitro antimicrobial efficacy was investigated. Candida albicans was used as a characteristic representative of pathogenic oral microflora. Staphylococcus aureus and Escherichia coli were used as the typical Gram-positive and Gram-negative bacterial strains, respectively. The effect of filler addition on the Shore A hardness, tensile strength, tensile bond strength, sorption, and solubility was investigated. An increase in the filler concentration resulted in an increase in hardness, sorption, and solubility, and for the highest concentration, a decrease in bond strength. The favorable combination of antimicrobial efficacy with other properties was achieved at filler concentrations ranging from 2% to 10%. These composites exhibited mechanical properties similar to the material without the antimicrobial filler and enhanced in vitro antimicrobial efficiency. PMID:29470441

  17. Antifungal Activity of Denture Soft Lining Material Modified by Silver Nanoparticles—A Pilot Study

    PubMed Central

    Chladek, Grzegorz; Mertas, Anna; Barszczewska-Rybarek, Izabela; Nalewajek, Teresa; Żmudzki, Jarosław; Król, Wojciech; Łukaszczyk, Jan

    2011-01-01

    Soft liner materials in oral cavity environments are easily colonized both by fungi and dental plaque. These factors are the cause of mucosal infections. The microorganism that most frequently colonizes soft liner materials is Candida albicans. Colonization occurs on the surface of materials and within materials. A solution to this problem might involve modification of soft liner materials with silver nanoparticles (AgNPs). In this article, we present results showing the antifungal efficacy of silicone soft lining materials modified with AgNPs. The modification process was conducted by dissolving both material components (base and catalyst) in a colloidal solution of AgNPs and evaporating the solvent. Composites with various AgNP concentrations (10, 20, 40, 80, 120 and 200 ppm) were examined. The in vitro antifungal efficacy (AFE) of composite samples was 16.3% to 52.5%. PMID:21845108

  18. Denture-induced fibrous inflammatory hyperplasia (epulis fissuratum): research aspects.

    PubMed

    Thomas, G A

    1993-01-01

    Denture-induced fibrous inflammatory hyperplasia (FIH) is a common lesion of the oral mucosa which can be treated by either surgical excision, conservative methods or both combined. Clinical aspects are briefly reviewed and a newer conservative approach to treatment is suggested. This is based on the observation that light pressure using soft lining materials may facilitate shrinkage of the fibrous mass. The histopathogenesis is discussed from the view point of the modern technologies of immunocytochemistry, and digital image analysis. The recent development of a microwave instrument with sophisticated control of power and temperature is discussed and its use in the field of histotechnology outlined.

  19. Effect of surface treatments on the bond strength of soft denture lining materials to an acrylic resin denture base.

    PubMed

    Gundogdu, Mustafa; Yesil Duymus, Zeynep; Alkurt, Murat

    2014-10-01

    Adhesive failure between acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to evaluate the effect of different surface treatments on the bond strength of 2 different resilient lining materials to an acrylic resin denture base. Ninety-six dumbbell-shaped specimens were fabricated from heat-polymerized acrylic resin, and 3 mm of the material was cut from the thin midsection. The specimens were divided into 6 groups according to their surface treatments: no surface treatment (control group), 36% phosphoric acid etching (acid group), erbium:yttrium-aluminum-garnet (Er:YAG) laser (laser group), airborne-particle abrasion with 50-μm Al2O3 particles (abrasion group), an acid+laser group, and an abrasion+laser group. The specimens in each group were divided into 2 subgroups according to the resilient lining material used: heat-polymerized silicone based resilient liner (Molloplast B) and autopolymerized silicone-based resilient liner (Ufi Gel P). After all of the specimens had been polymerized, they were stored in distilled water at 37°C for 1 week. A tensile bond strength test was then performed. Data were analyzed with a 2-way ANOVA, and the Sidak multiple comparison test was used to identify significant differences (α=.05). The effects of the surface treatments and resilient lining materials on the surface of the denture base resin were examined with scanning electron microscopy. The tensile bond strength was significantly different between Molloplast B and Ufi Gel P (P<.001). The specimens of the acid group had the highest tensile bond strength, whereas those of the abrasion group had the lowest tensile bond strength. The scanning electron microscopy observations showed that the application of surface treatments modified the surface of the denture base resin. Molloplast B exhibited significantly higher bond strength than Ufi Gel P. Altering the surface of the acrylic resin denture base with 36% phosphoric acid etching increased bond strength. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Sub-Periosteal Dissection with Denture-Guided Epithelial Regeneration: A Novel Method for Peri-Implant Soft Tissue Management in Reconstructed Mandibles.

    PubMed

    Kumar, Vinay V; Jacob, P C; Kuriakose, Moni A

    2016-12-01

    In patients with reconstructed mandibles using free fibula flaps, management of soft tissues around implants supporting dental rehabilitation, is often a clinical problem. The aim of this paper is to describe a new technique, namely "Sub-periosteal dissection and denture-guided epithelial regeneration (SD-DGER)", as a method of peri-implant soft tissue management in these patients. The technique consists of performing a subperiosteal dissection with creation of buccal and lingual flaps. These flaps form the buccal and lingual vestibule. Implants are placed and an interim denture is immediately loaded onto the implants to guide the regenerated epithelium. A keratinized mucosal layer is formed on the bare fibula bone in six months time. This technique was successful in producing fixed keratinized epithelial tissue around implants in patients with mandibles reconstructed using the free fibula flap in patients who did not undergo radiotherapy. The sub-periosteal dissection with denture guided epithelial regeneration is a predictable form of peri-implant soft tissue management in selected patients with reconstructed jaws.

  1. Comparison of the Effect of two Denture Cleansers on Tensile bond Strength of a Denture Liner.

    PubMed

    Farzin, M; Bahrani, F; Adelpour, E

    2013-09-01

    One of the most clinical challenging issues in prosthodontics is debonding of soft liners from the denture base. The aim of this study was to evaluate and compare tensile bond strength between soft liner and heat-cured acrylic resin when immersed in two different types of denture cleanser and distilled water, at different period of times. In this experimental in vivo study, 238 heat-cured acrylic blocks were made. A soft liner was embedded between the acrylic blocks. Samples were divided into four groups: 17 samples were in the control group and were not soaked in any solution .The remaining samples were divided into 3 groups (Distilled water, Calgon and Fittydent). Each group was then subdivided into two subcategories, regarding the immersion time variable; 15 and 45 minutes. All samples were placed in tension force and tensile bond strength was recorded with the testing machine. One- way ANOVA and Tucky HSD post-hoc test were adopted to analyze the yielded data (α> 0.05). Specimens which were immersed in two denture cleansers (Fittydent and Calgon) and in distilled water showed significant difference (p= 0.001) in bonding strength when compared to the control group. The subjects immersed in denture cleanser solutions and distilled water did not reveal any significant difference (p= 0.90). For all groups; most of the bonding failures (72%) were cohesive type. The effect of the denture cleansers and distilled water on the bond strength was not statistically different; however, the difference was significant between the immersed groups with the non-immersed group. Moreover, type of the denture cleanser did not show any effect on the tensile strength. The tensile strength increases with time of immersion.

  2. Effect of artificial saliva with different pH levels on the cytotoxicity of soft denture lining materials.

    PubMed

    Akay, Canan; Tanış, Merve Ç; Sevim, Handan

    2017-10-13

    The aim of this study was to evaluate the cytotoxic effects of 9 different soft denture liners on the viability of L-929 mouse fibroblast cells at different incubation periods by storing them in artificial saliva (AS) with different pH levels. 96 disk samples from each lining material were prepared and divided into 4 groups: GI: No treatment; GII: Stored in artificial saliva with pH 3 for 21 days; Group III: Stored in artificial saliva with pH 7 for 21 days; and Group IV: Stored in artificial saliva with pH 14 for 21 days. The cytotoxicity of the extracts to cultured mouse fibroblasts (L-929) was measured by MTT (tetrazolium salt 3-[4,5-dimethylthiazol-2-yl]-2,5-dipHnyltetrazolium bromide) assay. Data were analyzed using 1-way analysis of variation (ANOVA). It was found that for the pH 3 values of New Truliner, Trusoft, Mollosil Plus, Dentusil, TDV, and HydroCast®; for the pH 7 values of Ufi Gel P and Elite plus; and for the pH 14 values of HydroCast®, there was a noncytotoxic effect during both the 24-hour and 48-hour incubation periods. In the control group 48-hour incubation period, HydroCast®, TDV, Mollosil, 24-hour incubation period Elite plus, for pH 3 values; Elite Plus 24-hour incubation period, for pH 7 values Trusoft 48-hour incubation period there was a moderately cytotoxic effect. This in vitro study revealed that storage in artificial saliva with different pH levels can affect the cytotoxicity of soft lining materials.

  3. A Three Month Comparative Evaluation of the Effect of Different Surface Treatment Agents on the Surface Integrity and Softness of Acrylic based Soft Liner: An In vivo Study

    PubMed Central

    Mahajan, Neerja; Naveen, Y. G.; Sethuraman, Rajesh

    2017-01-01

    Introduction Acrylic based soft liners are cost effective, yet are inferior in durability as compared to silicone based liners. Hence, this study was conducted to evaluate if the softness and surface integrity of acrylic based soft liner can be maintained by using different surface treatment agents. Aim To comparatively evaluate the effects of Varnish, Monopoly and Kregard surface treatment agents on the surface integrity and softness of acrylic based soft liner at baseline, at one month and after three months. Materials and Methods A total of 37 participants who required conventional maxillary dentures were selected according to the determined inclusion and exclusion criteria of the study. In the maxillary denture on the denture bearing surface, eight palatal recesses (5 mm x 3 mm) were made and filled with acrylic based soft liner (Permasoft). The soft liners in these recesses were given surface treatment and divided as control (uncoated), Varnish, Monopoly and Kregard groups. The hardness and surface integrity were evaluated with Shore A Durometer and Scanning Electron Microscope (SEM) respectively at baseline, one month and three months interval. Surface integrity between groups was compared using Kruskal-Wallis test. Intergroup comparison for hardness was done using ANOVA and Tukey’s HSD post-hoc tests. Results Amongst all the groups tested, surface integrity was maintained in the Kregard group, as compared to control, Varnish and Monopoly groups for all three time intervals (p< 0.001). Kregard treated samples also demonstrated significantly higher softness at all the time intervals (p<0.001). Conclusion Surface treatment with Kregard demonstrated better surface integrity and softness at all the time intervals. PMID:29207842

  4. Effect of long-time immersion of soft denture liners in water on viscoelastic properties.

    PubMed

    Iwasaki, Naohiko; Yamaki, Chisato; Takahashi, Hidekazu; Oki, Meiko; Suzuki, Tetsuya

    2017-09-26

    Aim of this study was to investigate the effect of long-time immersion of soft denture liners in 37°C water on viscoelastic properties. Six silicone-based and two acrylic resin-based soft denture liners were selected. Cylindrical specimens were stored in distilled water at 37°C for 6 months. Viscoelastic properties, which were instantaneous and delayed elastic displacements, viscous flow, and residual displacement, were determined using a creep meter, and analyzed with 2-way analysis of variance and Tukey's comparison (α=0.05). Viscoelastic properties and their time-dependent changes were varied among materials examined. The observed viscoelastic properties of three from six silicone-based liners did not significantly change after 6-month immersion, but those of two acrylic resin-based liners significantly changed with the increase of immersion time. However, the sum of initial instantaneous elastic displacement and delayed elastic displacement of two acrylic resin-based liners during 6-month immersion changed less than 10%, which might indicate clinically sufficient elastic performance.

  5. Effect of different surface treatments on tensile bond strength of silicone-based soft denture liner.

    PubMed

    Akin, Hakan; Tugut, Faik; Mutaf, Burcu; Akin, Gulsah; Ozdemir, A Kemal

    2011-11-01

    Failure of the bond between the acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to investigate the effect of different surface treatments (sandblasting, Er:YAG, Nd:YAG, and KTP lasers) on tensile bond strength of silicone-based soft denture liner. Polymethyl methacrylate test specimens were fabricated and each received one of eight surface treatments: untreated (control), sandblasted, Er:YAG laser irradiated, sandblasted + Er:YAG laser irradiated, Nd:YAG laser irradiated, sandblasted + Nd:YAG laser irradiated, KTP laser irradiated, and sandblasted + KTP laser irradiated. The resilient liner specimens (n = 15) were processed between two polymethyl methacrylate (PMMA) blocks. Bonding strength of the liners to PMMA were compared by tensile test with the use of a universal testing machine at a crosshead speed of 5 mm/min. Kruskal-Wallis and Wilcoxon tests were used to analyze the data (α = 0.05). Altering the polymethyl methacrylate surface by Er:YAG laser significantly increased the bond strengths in polymethyl methacrylate/silicone specimens, however, sandblasting before applying a lining material had a weakening effect on the bond. In addition, Nd:YAG and KTP lasers were found to be ineffective for increasing the strength of the bond.

  6. The dental health of factory workers in Pasir Gudang, Johor (Malaysia).

    PubMed

    Abdul Majid, Z; Zain, R B

    1988-05-01

    A study on the oral health status of 198 factory workers (in Antara Steel, Pasir Gudang, Johor) was carried out in November 1986. The subjects were predominantly male (94%) and Malay (91%) with an average age of 27.4 years. The prevalence of caries was 87.4% with a mean DMFT of 7.1 + 5.4. There were 3 subjects with full upper, lower dentures and 16 subjects with partial dentures. Two subjects examined needed dentures but were not wearing them. Thirty five (17.7%) of those examined needed urgent extractions, and 8 needed emergency treatment for fillings. Enamel opacities were found in 141 subjects (75.6%) but only 9 were aware of these defects. Dental health was very poor with 72% examined needing scaling. Seventeen (9%) had gross supra and subgingival calculus. There was a total of 107 (54%) smokers and heavy nicotine stains were found in 41 (20.7%), of the population examined. Examination of soft tissues showed 111 (56%) subjects with recurrent aphthous ulcers whilst 15 (7.6%) suffered from herpes labialis. Five subjects (2.5%) suffered from denture stomatitis whilst the prevalence of other soft tissue lesions was very low.

  7. Photoelastic analysis to compare implant-retained and conventional obturator dentures

    NASA Astrophysics Data System (ADS)

    Goiato, Marcelo Coelho; Prado Ribeiro, Paula do; Pellizzer, Eduardo Piza; Pesqueira, Aldiéris Alves; Haddad, Marcela Filiè; dos Santos, Daniela Micheline; Moreno, Amália

    2012-06-01

    The use of photoelastic analysis contributes to the rehabilitation of patients with oral-sinus-nasal sequelae, which in turn affect important functions such as chewing, swallowing, and speech. The prosthetic rehabilitation with implant-retained dentures is a suitable treatment option. The purpose of this study was to verify, by using a photoelastic analysis, the stress distribution in implant-retained palatal obturator dentures (relined or not) associated with different attachment systems (O-ring, bar-clip, and bar-clip associated with distally placed O-rings). Two photoelastic models were obtained from an experimental maxillary cast presenting an oral-nasal communication. One model had two 13-mm length implants placed on the left region. A total of eight colorless maxillary obturators were fabricated and subsequently four of them were relined with soft silicone soft, and three had attachment systems associated. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a 100-N load was applied at 10 mm/s. The results showed that the denture relining influenced the distribution and amount of stress on the models. The O-ring group displayed the lowest stress levels, followed by bar-clip system associated with distally placed O-rings and bar-clip groups.

  8. In situ evaluation of surface roughness and micromorphology of temporary soft denture liner materials at different time intervals.

    PubMed

    Araújo, Célio U; Basting, Roberta T

    2018-03-01

    To perform an in situ evaluation of surface roughness and micromorphology of two soft liner materials for dentures at different time intervals. The surface roughness of materials may influence the adhesion of micro-organisms and inflammation of the mucosal tissues. The in situ evaluation of surface roughness and the micromorphology of soft liner materials over the course of time may present results different from those of in vitro studies, considering the constant presence of saliva and food, the changes in temperature and the pH level in the oral cavity. Forty-eight rectangular specimens of each of the two soft liner materials were fabricated: a silicone-based material (Mucopren Soft) and an acrylic resin-based material (Trusoft). The specimens were placed in the dentures of 12 participants (n = 12), and the materials were evaluated for surface roughness and micromorphology at different time intervals: 0, 7, 30 and 60 days. Roughness (Ra) was evaluated by means of a roughness tester. Surface micromorphology was evaluated by scanning electron microscopy. Analysis of variance for randomised block design and Tukey's test showed that surface roughness values were lower in the groups using the silicone-based material at all the time intervals (P < .0001). The average surface roughness was higher at time interval 0 than at the other intervals, for both materials (P < .0001). The surface micromorphology showed that the silicone material presented a more regular and smoother surface than the acrylic resin-based material. The surface roughness of acrylic resin-based and silicone-based denture soft liner materials decreased after 7 days of evaluation, leading to a smoother surface over time. The silicone-based material showed lower roughness values and a smoother surface than the acrylic resin-based material, thereby making it preferred when selecting more appropriate material, due its tendency to promote less biofilm build-up. © 2017 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  9. Biting Force and Muscle Activity in Implant-Supported Single Mandibular Overdentures Opposing Fixed Maxillary Dentition.

    PubMed

    Al-Magaleh, Wafaʼa R; Abbas, Nadia A; Amer, Ashraf A; Abdelkader, Ann A; Bahgat, Basma

    2016-04-01

    This study aimed to investigate the relation between biting force and masticatory muscle activity in patients treated by 3 modalities of single mandibular dentures. Forty implants were placed in 10 patients with completely edentulous mandibles. The study was divided into 3 treatment stages. Initially, each patient received a conventional mandibular complete denture. At the second stage, 4 mandibular implants were placed and the denture was refitted to their abutments. Third stage comprised connecting the denture to the implants through ball attachments. During each treatment stage, maximum biting force and muscle activity were measured during maximum clenching and chewing of soft and hard food. Biting force demonstrated a statistically significant increase by time for the 3 treatment stages. The highest muscle activity was recorded for the conventional denture followed by the implant-supported overdenture without attachment, whereas the lowest values were recorded for the implant-supported overdenture with attachment. Biting force was related mainly to the quality of denture support. Muscle activity was higher in patients with conventional denture than with implant-supported prostheses (with or without attachments).

  10. Mucous retention cyst of the soft palate: a case presentation.

    PubMed

    Ellis, S G; Lee, N J; Peckitt, N S

    1995-12-01

    This article describes a mucous retention cyst of the soft palate associated with an over-extended complete maxillary denture. The clinical and anatomical relevance of the fovea palatinae are discussed with respect to the posterior palatal seal and post-dam positioning.

  11. Comparative evaluation of tensile bond strength of a polyvinyl acetate-based resilient liner following various denture base surface pre-treatment methods and immersion in artificial salivary medium: An in vitro study.

    PubMed

    Philip, Jacob M; Ganapathy, Dhanraj M; Ariga, Padma

    2012-07-01

    This study was formulated to evaluate and estimate the influence of various denture base resin surface pre-treatments (chemical and mechanical and combinations) upon tensile bond strength between a poly vinyl acetate-based denture liner and a denture base resin. A universal testing machine was used for determining the bond strength of the liner to surface pre-treated acrylic resin blocks. The data was analyzed by one-way analysis of variance and the t-test (α =.05). This study infers that denture base surface pre-treatment can improve the adhesive tensile bond strength between the liner and denture base specimens. The results of this study infer that chemical, mechanical, and mechano-chemical pre-treatments will have different effects on the bond strength of the acrylic soft resilient liner to the denture base. Among the various methods of pre-treatment of denture base resins, it was inferred that the mechano-chemical pre-treatment method with air-borne particle abrasion followed by monomer application exhibited superior bond strength than other methods with the resilient liner. Hence, this method could be effectively used to improve bond strength between liner and denture base and thus could minimize delamination of liner from the denture base during function.

  12. 21 CFR 872.3560 - OTC denture reliner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... applied as a permanent coating or lining on the base or tissue-contacting surface of a denture. The device... Reliners, Repair Kits, and Partially Fabricated Denture Kits.” [52 FR 30097, Aug. 12, 1987, as amended at...

  13. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading.

    PubMed

    Im, So-Min; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin

    2017-02-01

    The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture ( P <.05) and the control group ( P <.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

  14. Remedy for Repeated Implant Retained Denture Fracture-A Challenging Case Report

    PubMed Central

    Reddy M, Ramu; Metta, Kiran Kumar; Charry N, Sudheer; B, Chittaranjan

    2014-01-01

    The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. PMID:25584333

  15. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

    PubMed Central

    2017-01-01

    PURPOSE The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr–Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS Glass fiber mesh- and Cr–Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair. PMID:28243388

  16. Cytotoxic effects of denture adhesives on primary human oral keratinocytes, fibroblasts and permanent L929 cell lines.

    PubMed

    Chen, Fengying; Wu, Tianfu; Cheng, Xiangrong

    2014-03-01

    To date, there have been very little data on the cytotoxic responses of different cell lines to denture adhesives. To determine the cytotoxicity of three denture adhesives on primary human oral keratinocytes (HOKs), fibroblasts (HOFs) and permanent mouse fibroblasts cell lines (L929). Three commercial denture adhesives (two creams and one powder) were prepared for indirect contact using the agar diffusion test, as well as extracts in MTT assay. The results of the MTT assay were statistically analysed by one-way anova and Tukey's test (p < 0.05). All of the tested denture adhesives showed mild to moderate cytotoxicity to primary HOKs (p < 0.001), whereas none of three was toxic to L929 cells (p > 0.05) in both assays. For primary HOFs cultures, slight cytotoxicity was observed for one of the products from the agar diffusion test and undiluted eluates of all tested adhesives with MTT assay (p < 0.01). Denture adhesives are toxic to the primary HOKs and HOFs cultures, whereas non-toxic to L929 cells. The results suggest that primary human oral mucosal cells may provide more valuable information in toxicity screening of denture adhesives. © 2012 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  17. Evaluation of hardness and colour change of soft liners after accelerated ageing.

    PubMed

    Mancuso, Daniela Nardi; Goiato, Marcelo Coelho; Zuccolotti, Bruna Carolina Rossatti; Moreno, Amália; dos Santos, Daniela Micheline

    2009-07-01

    Soft liners have been developed to offer comfort to denture wearers. However, this comfort is compromised when there is a change in the properties of the material, causing colour change, solubility, absorption and hardening. These characteristics can compromise the longevity of soft liners. The aim of this in vitro study was to investigate the effect of ageing on both the hardness and colour change of two soft liners following accelerated ageing. Two denture liners, one resin based (Trusoft, Bosworth, Illinois, USA) and one silicone based (Ufi Gel P, Voco GMBH, Cuxhaven, Germany), were tested in this study for both hardness (using the Shore A scale) and colour change (using the CIE L*a*b* colour scale), initially and after 1008 hours (6 weeks) of accelerated ageing. Statistical analysis was performed using the unpaired t-test with the Welch correction. These indicated that both materials increased in hardness and underwent colour change after accelerated ageing. The initial hardness of Trusoft was far lower than that of Ufi Gel P (18.2 Shore A units vs 34.8 Shore A units). However, for Trusoft the changes for both hardness (from 18.2 to 52.1 Shore A units) and colour change (16.85 on the CIE L*a*b* colour scale) were greater than those for Ufi Gel P, for which hardness changed from 34.8 to 36.5 Shore A units and the colour change was 5.19 on the CIE L*a*b* colour scale. Ufi Gel P underwent less hardness and colour change after accelerated ageing than Trusoft. On the other hand, the use of Trusoft may be preferable in cases where initial softness is a major consideration, such as when relining an immediate denture after implant surgery.

  18. The effect of denture base surface pretreatments on bond strengths of two long term resilient liners

    PubMed Central

    Parkhedkar, Rambhau

    2011-01-01

    PURPOSE Purpose of this study was to evaluate effect of two surface treatments, sandblasting and monomer treatment, on tensile bond strength between two long term resilient liners and poly (methyl methacrylate) denture base resin. MATERIALS AND METHODS Two resilient liners Super-Soft and Molloplast-B were selected.Sixty acrylic resin (Trevalon) specimens with cross sectional area of 10×10 mm were prepared and divided into two groups of 30 specimens each. Each group was surface treated (n = 10) by sandblasting (250 µ alumina particles), monomer treatment (for 180 sec) and control (no surface treatment). Resilient liners were processed between 2 poly(methyl methacrylate) surfaces, in the dimensions of 10×10×3 mm. Tensile strength was determined with Instron Universal testing machine, at a crosshead speed of 5 mm/min; and the modes of failure (adhesive, cohesive or mixed) were recorded. The data were analyzed using one-way ANOVA, followed by Tukey HSD test (α = 0.05). RESULTS Monomer pretreatment of acrylic resin produced significantly higher bond strengths when compared to sandblasting and control for both resilient liners (P < .001). Sandblasting significantly decreased the bond strength for both the liners when compared to monomer pretreatment and control (P < .001). Mean bond strength of Super-Soft lined specimens was significantly higher than Molloplast-B in various surface treatment groups (P < .05). CONCLUSION Surface pretreatment of the acrylic resin with monomer prior to resilient liner application is an effective method to increase bond strength between the base and soft liner. Sandblasting, on the contrary, is not recommended as it weakens the bond between the two. PMID:21503188

  19. Microtensile bond strength of different acrylic teeth to high-impact denture base resins.

    PubMed

    Colebeck, Amanda C; Monaco, Edward A; Pusateri, Christopher R; Davis, Elaine L

    2015-01-01

    This study evaluated the effect of denture base acrylic, denture tooth composition, and ridge-lap surface treatment on the microtensile bond strength (μTBS) of three commercially available denture teeth and two injection denture processing systems. Sixteen experimental groups were formed (n = 3), according to denture tooth surface treatment (no treatment or surface treatment recommended by the manufacturer), denture base processing technique and acrylic (SR-Ivocap-Ivocap Plus or Success-Lucitone 199), and tooth type-composition at bonding interface (BlueLine DCL-PMMA, Portrait IPN-PMMA, Phonares II-PMMA, Phonares II-NHC). Rectangular bar specimens with a 1 mm(2) cross sectional area were fabricated and subsequently thermocycled at 10,000 cycles between 5°C and 55°C with a 15-second dwell time. Select specimens underwent μTBS testing in a universal testing machine with a 1 kN load cell at 0.5 mm/min crosshead speed. Data were analyzed statistically by two and three-way ANOVA and Tukey post hoc test (α = 0.05). Mean μTBS ranged between 56.2 ± 5.6 and 60.8 ± 5.0 N/mm(2) for the Ivocap Plus specimens and 13.3 ± 5.12 to 60.1 ± 6.0 N/mm(2) for the Lucitone 199 specimens. Among the Ivocap specimens, BlueLine DCL and Phonares II NHC had significantly higher μTBS than Portrait IPN to Ivocap Plus acrylic. There were no statistically significant differences among Blueline, Phonares II PMMA, and Phonares II NHC, or between Phonares II PMMA and Portrait IPN. Within the Luctione 199 specimens, there was a significantly higher μTBS for BlueLine DCL and Phonares II NHC denture teeth with the manufacturer-recommended surface treatment when compared to control surface. BlueLine, Portrait, and Phonares II PMMA groups achieved significantly higher mean μTBS than the Phonares II NHC group. There were no statistically significant differences among BlueLine, Portrait, and Phonares II PMMA groups. When evaluating the μTBS of PMMA and NHC denture teeth to base resins, a stronger bond was achieved using materials produced by the same manufacturer. Within the Luctione 199 specimens, the Phonares II NHC group demonstrated significantly lower bond strength than other specimens, suggesting that gross ridge-lap reduction of NHC denture teeth is not recommended if a base acrylic by a different manufacturer from the tooth is going to be used. © 2014 American College of Prosthodontists.

  20. Effect of potentially chromogenic beverages on shear bond strength of acrylic denture teeth to heat-polymerized denture base resins

    PubMed Central

    Neppelenbroek, Karin Hermana; Urban, Vanessa Migliorini; de Oliveira, Denise Gusmão; Porto, Vinícius Carvalho; Almilhatti, Hercules Jorge; Campanha, Nara Hellen

    2016-01-01

    Background: Detachment of denture acrylic resin artificial teeth from denture base resin is one of the most common problems presented by denture wearers. Purpose: This study investigated the shear bond strength (SBS) and fracture type of bonding interface of two commercial acrylic teeth (Vipi Dent Plus e Biolux) to two denture base resins (Vipi Cril e Lucitone 550) after immersion in potentially chromogenic beverages (coffee, cola soft drink, and red wine) or control solution (distilled water). Materials and Methods: Maxillary central incisor acrylic teeth were placed at 45° to denture base resin and submitted to short polymerization cycle according to manufacturers. Specimens were divided according to the combination tooth/resin/solution (n = 8) and submitted to bond strength tests in a universal testing machine MTS-810 (0.5 mm/min). Subsequently, fracture area was analyzed by stereomicroscope at a magnification of ×10 and categorized into adhesive, cohesive, or mixed failure. Results: The bond strength of teeth/denture base resins interface was not significantly affected by tested solutions (P > 0.087), except for Biolux teeth immersed in coffee (P < 0.01). In all conditions, the Vipi Dent Plus teeth showed higher bond strength to Lucitone and Vipi Cril resins when compared to Biolux teeth (P < 0.003). All specimens’ failure modes were cohesive. Conclusions: The SBS of acrylic teeth to denture base resins was not generally influenced by immersion in the tested staining beverages. PMID:27621547

  1. Effect of maleic anhydride pretreatment on tensile bond strength of a silicone soft liner to a denture base polymer.

    PubMed

    Demir, Hakan; Soygun, Koray; Dogan, Arife; Keskin, Selda; Dogan, Orhan Murat; Bolayir, Giray

    2011-10-01

    To determine the effect of resin surface treatment with dissolved maleic anhydride in butanone added into primer on the tensile bond strength between an acrylic denture base resin and a silicone soft liner. To test tensile bond strength, standard dumbbell-shaped acrylic specimens were prepared. Five experimental groups, including the control, were tested (n = 5). Maleic anhydride solutions prepared in butanone at concentrations of 1%, 5%, 10% or 20% were then mixed with 1 ml of Primo adhesive and the mixtures were applied onto the resin bonding surfaces. Silicone liner material was applied to resin surfaces in the conventional manner. Tensile bond strength of the specimens was measured in a universal testing machine. Fractured surfaces were observed under the scanning electron microscope, and resulting chemical changes with the solutions used were analyzed spectroscopically. The highest bond strength value was obtained for the group treated with 5% maleic anhydride (2.53 ± 0.48 MPa); the lowest value was for the group treated with 20% maleic anhydride (1.59 ± 0.29 MPa). Mixed failure was the dominant type seen in the experimental groups. Spectroscopic analysis showed the interaction of the anhydride carbonyl groups with the Primo primer. The treatment of resin surfaces with maleic anhydride added to Primo adhesive effectively increased bond strength between silicone soft liner and denture base resin.

  2. Evaluation of tensile bond strength of heat cure and autopolymerizing silicone-based resilient denture liners before and after thermocycling.

    PubMed

    Madan, Nishtha; Datta, Kusum

    2012-01-01

    To assess the effect of simulated mouth conditions reproduced with thermocycling on the tensile bond strength of two silicone based resilient denture liners with acrylic resin bases. Two silicone-based soft denture liners (Mollosil - Chairside autopolymerization and Molloplast B - Heat polymerization) were tested. For each liner, 30 specimens with a cross-sectional area of 10 Χ 10 mm and thickness 3 mm were processed between two acrylic blocks (Trevalon). Specimens were divided into a control group that was stored for 24 hours in water at 37°C and a test group that was thermocycled (2500 cycles) between baths of 5° and 55°C. Tensile bond strength (kg/cm²) was determined in a universal testing machine using crosshead speed of 5 mm/min. The student t-test was used to determine the significance of the difference in bond strength between the two liners. The mean tensile bond strength for control and thermocycled specimens of the two liners were: Mollosil (6.82 kg/cm² and 8.41 kg/cm²) and Molloplast-B (16.30 kg/cm² and 13.67 kg/cm²), respectively. Comparison of bond strength of control specimens with thermocycled specimens of the liners indicated a significant difference for both Mollosil (P=0.045) and Molloplast-B (P=0.027). Comparison between control specimens of both liners and thermocycled specimens of both liners indicated a highly significant difference (P<0.001). Heat polymerized resilient denture liner Molloplast-B had higher tensile bond strength than autopolymerizing liner Mollosil regardless of thermocycling. The bond strength of Mollosil increased after thermocycling while that of Molloplast-B decreased after thermocycling. Although heat-polymerized denture liners require more processing time than autopolymerizing liners, but they display much better adhesion properties to denture base resin and should thus be preferred when soft liner has to be used for a longer duration of time.

  3. Food selection and perceptions of chewing ability following provision of implant and conventional prostheses in complete denture wearers.

    PubMed

    Allen, Finbarr; McMillan, Anne

    2002-06-01

    The loss of natural teeth compromises chewing efficiency, and edentulous patients often have a diet that is deficient in fibre and vitamins. Prostheses that are retained on implants offer the possibility of overcoming some of the limitations of conventional dentures in terms of chewing efficiency. The aim of this study was to test the hypothesis that improvement in satisfaction with oral prostheses would result in improved food selection in edentulous patients. This prospective study involved three groups, namely (i) subjects who requested and received implants to stabilise a complete fixed or removable prosthesis (IG, n = 26), (ii) edentulous subjects who requested implant prostheses, but received conventional dentures (CDG1, n = 22), and (iii) edentulous subjects who requested and received conventional dentures (CDG2, n = 35). Data were collected using validated questionnaires pre- and postoperatively. Prior to treatment, all subjects were asked whether they ate a variety of hard and soft foods, to indicate the degree of difficulty they experienced when chewing these foods, and to rate their satisfaction with various aspects of their maxillary and mandibular complete dentures. Following the completion of treatment, subjects completed the questionnaires again. Pre- and postoperative data were compared. Subjects who received implant prostheses reported significant improvement in chewing hard and soft foods. CDG2 subjects also reported improvement, but CDG1 subjects reported no change or even deterioration following treatment. Despite reported improvement in satisfaction with comfort and ability to chew food, 30-50% of IG and CDG2 subjects still avoided eating foods such as carrot and apple. This suggests that, in the absence of tailored dietary advice, apparently successful prosthetic rehabilitation does not necessarily result in a satisfactory diet.

  4. Effect of denture cleansing agents on tensile and shear bond strengths of soft liners to acrylic denture base.

    PubMed

    Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa

    2017-01-01

    Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups.

  5. Effect of denture cleansing agents on tensile and shear bond strengths of soft liners to acrylic denture base

    PubMed Central

    Mahboub, Farhang; Salehsaber, Fariba; Parnia, Fereydoon; Gharekhani, Vahedeh; Kananizadeh, Yousef; Taghizadeh, Mahsa

    2017-01-01

    Background. The aim of the present study was to evaluate the effect of Corega and 2.5% sodium hypochlorite cleansing agents on the shear and tensile bond strengths of GC soft liner to denture base. Methods. A total of 144 samples (72 samples for tensile and 72 for shear bond strength evaluations) were prepared. The samples in each group were subdivided into three subgroups in terms of the cleansing agent used (2.5% sodium hypochlorite, Corega and distilled water [control group]). All the samples were stored in distilled water, during which each sample was immersed for 15 minutes daily in sodium hypochlorite or Corega solutions. After 20 days the tensile and shear bond strengths were determined using a universal testing machine. In addition, a stereomicroscope was used to evaluate fracture modes. Data were analyzed with one-way ANOVA, using SPSS 16. Results. The results of post hoc Tukey tests showed significant differences in the mean tensile and shear bond strength values between the sodium hypochlorite group with Corega and control groups (P=0.001 for comparison of tensile bond strengths between the sodium hypochlorite and control groups, and P<0.001 for the comparison of tensile bond strengths between the sodium hypochlorite and Corega groups and the shear bond strengths between the sodium hypochlorite and Corega groups, and sodium hypochlorite and control groups).The majority of failures were cohesive in the control and Corega groups and cohesive/adhesive in the sodium hypochlorite group. Conclusion. Immersion of soft liners in Corega will result in longevity of soft liners compared to immersion in sodium hypochlorite solution and sodium hypochlorite solution significantly decreased the tensile and shear bond strengths compared to the control and Corega groups. PMID:29184635

  6. Antifungal Efficacy and the Mechanical Properties of Soft Liners against Candida albicans after the Incorporation of Garlic and Neem: An In vitro Study

    PubMed Central

    Kumar, Seenivasan Madhan; Kumar, V. Anand; Natarajan, Parathasarthy; Sreenivasan, Gayathri

    2018-01-01

    Objectives: To evaluate the in vitro growth inhibition of Candida albicans, in the soft-liner material and Shore A hardness from resin-based denture soft lining materials modified by neem or garlic incorporation. Materials and Methods: Resin discs were prepared with poly methyl methacrylate (PMMA) and soft liners incorporated with varying concentrations of neem or garlic. For antifungal activity, resin discs were placed on agar plates inoculated with C. albicans and were evaluated after 2, 4, and 7 days using the streaking method. The hardness of the PMMA was evaluated with the use of Shore A at 2, 4, and 7 days. Data were statistically processed by SPSS software (IBM Company, Chicago, USA) using Kruskal–Wallis test, and post hoc comparisons were done using Dunn's test. P <0.05 was considered statistically significant. Results: Neem and garlic added to PMMA soft liner had an inhibitory effect on C. albicans. Both the neem and garlic when added showed positive results against C. albicans when compared to the control group. The soft liner hardness increased statistically by time but not for the different plant extract concentrations. Conclusions: Within the limitations of this in vitro study, it was found that neem and garlic can be used as an additive to tissue conditioner to reduce the adherence of C. albicans without significantly affecting the hardness of the heat-polymerized acrylic resin. PMID:29911057

  7. The effect of two fibre impregnation methods on the cytotoxicity of a glass and carbon fibre-reinforced acrylic resin denture base material on oral epithelial cells and fibroblasts.

    PubMed

    Sipahi, Cumhur; Ozen, Julide; Ural, A Ugur; Dalkiz, Mehmet; Beydemir, Bedri

    2006-09-01

    Acrylic resin dentures may have cytotoxic effects on oral soft tissues. However, there is sparse data about the cytotoxic effect of fibre-reinforced acrylic resin denture base materials. The purpose of this in vitro study was to determine the effect of two fibre impregnation methods on the cytotoxicity of a glass and carbon fibre-reinforced heat-polymerized acrylic resin denture base material on oral epithelial cells and fibroblasts. One hundred acrylic resin discs were assigned to five experimental groups (n = 20). One of the groups did not include any fibre. Two groups consisted of silane and monomer treated glass fibres (Vetrolex) impregnated into acrylic resin (QC-20) discs. The other two groups consisted of silane and monomer treated carbon fibres (Type Tenox J, HTA). Untreated cell culture was used as positive control. The human oral epithelial cell line and buccal fibroblast cultures were exposed to test specimens. The cytotoxicity of the test materials was determined by succinic dehydrogenase activity (MTT method) after 24 and 72 h exposures. Data were analysed with a statistical software program (SPSSFW, 9.0). A one-way analysis of variance (anova) test and Bonferroni test were used for the comparisons between the groups. All statistical tests were performed at the 0.95 confidence level (P < 0.05). After 24 and 72 h incubation, cell viability percentages of all experimental groups showed significant decrease according to the positive control cell culture. Fibroblastic cell viability percentages of silane and monomer treated fibre-reinforced groups were lower than the unreinforced group. Cell viability of monomer-treated groups displayed the lowest percentages. Elapsed incubation time decreased epithelial cell viability in silane-treated groups. Fibroblastic cell viability was not influenced by elapsed time except the unreinforced group.

  8. Comparison of two cleansing pastes for the removal of biofilm from dentures and palatal lesions in patients with atrophic chronic candidiasis.

    PubMed

    Andrucioli, Marcela Cristina Damião; de Macedo, Leandro Dorigan; Panzeri, Heitor; Lara, Elza Helena Guimarães; Paranhos, Helena de Freitas Oliveira

    2004-01-01

    The efficacy of 2 oral hygiene products, an experimental toothpaste specific for complete denture cleansing and a regular standard toothpaste, was compared in terms of denture biofilm removal and cure of palatal lesions in patients with atrophic chronic candidiasis. The degree of correlation between presence of biofilm and mucosa erythema was also evaluated. Twenty-four complete denture wearers (45-80 years old) were divided into 2 groups: experimental paste and standard toothpaste (Sorriso-Kolynos, Brazil). Both groups received soft toothbrushes. The internal surfaces of upper dentures were stained using 1% sodium fluorescein and photographed at a 45 masculine angle at 0, 15, 30 and 60 days. The slides were scanned and the areas of interest (denture total area and biofilm area) were measured (Image Tool software). The degree of erythema was evaluated on slides according to the Prosthesis Tissue Index. There was a significant reduction (1%) in the degree of biofilm (ANOVA/Tukey) between the two initial visits (0 and 15 days) and the two final visits (30 and 60 days), and in the average erythema scores (Kruskal-Wallis) between 0 and 60 days, in both groups. The Mann-Whitney test showed a significant difference (1%) between pastes in terms of biofilm degree, but no difference was found for the erythema score. Correlation values between biofilm and erythema degree were 0.3801 (experimental paste) and (0.3678 (standard toothpaste). We may therefore conclude that the experimental product was efficient for the removal of denture plaque biofilm.

  9. Denture-related hyperplasia: a clinical study of a Turkish population group.

    PubMed

    Canger, Emin Murat; Celenk, Peruze; Kayipmaz, Saadettin

    2009-01-01

    Inflammatory fibrous hyperplasia (epulis fissuratum) (IFH) and inflammatory papillary hyperplasia (IPH) are oral mucosal diseases caused by ill-fitting denture wearing. A study was carried out on a group of Turkish people consisted of 131 female and 39 male complete denture wearers (n= 170) distributed in two age groups (30-60 and 60-80 years old). The analysis of data collected from patients showed that while the incidence of IFH was higher in women than in men, the incidence of IPH was similar. Most lesions were found in the 30-60 year-old group. The incidence of lesions increased as the denture wearing period increased. Soft tissue growth was the main complaint of the patients with IFH and IPH. In the maxilla, the incidence of IFH was higher than IPH. There was also a significant difference between the distribution of the lesion types in the jaws. There were a larger number of lesions in the maxilla compared to the mandible and most IFH lesions were located in the anterior region of the jaws.

  10. Porosity of temporary denture soft liners containing antifungal agents

    PubMed Central

    Lima, Jozely Francisca Mello; Maciel, Janaína Gomes; Hotta, Juliana; Vizoto, Ana Carolina Pero; Honório, Heitor Marques; Urban, Vanessa Migliorini; Neppelenbroek, Karin Hermana

    2016-01-01

    ABSTRACT Incorporation of antifungals in temporary denture soft liners has been recommended for denture stomatitis treatment; however, it may affect their properties. Objective: To evaluate the porosity of a tissue conditioner (Softone) and a temporary resilient liner (Trusoft) modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm. Material and Methods: The porosity was measured by water absorption, based on exclusion of the plasticizer effect. Initially, it was determined by sorption isotherms that the adequate storage solution for specimens (65×10×3.3 mm) of both materials was 50% anhydrous calcium chloride (S50). Then, the porosity factor (PF) was calculated for the study groups (n=10) formed by specimens without (control) or with drug incorporation at MICs (nystatin: Ny-0.032 g, chlorhexidine diacetate: Chx-0.064 g, or ketoconazole: Ke-0.128 g each per gram of soft liner powder) after storage in distilled water or S50 for 24 h, seven and 14 d. Data were statistically analyzed by 4-way repeated measures ANOVA and Tukey's test (α=.05). Results: Ke resulted in no significant changes in PF for both liners in water over 14 days (p>0.05). Compared with the controls, Softone and Trusoft PFs were increased at 14-day water immersion only after addition of Ny and Chx, and Chx, respectively (p<0.05). Both materials showed no significant changes in PF in up to 14 days of S50 immersion, compared with the controls (p>0.05). In all experimental conditions, Softone and Trusoft PFs were significantly lower when immersed in S50 compared with distilled water (p<0.05). Conclusions: The addition of antifungals at MICs resulted in no harmful effects for the porosity of both temporary soft liners in different periods of water immersion, except for Chx and Ny in Softone and Chx in Trusoft at 14 days. No deleterious effect was observed for the porosity of both soft liners modified by the drugs at MICs over 14 days of S50 immersion. PMID:27812615

  11. Effect of Incorporation of Antifungal Agents on the Ultimate Tensile Strength of Temporary Soft Denture Liners.

    PubMed

    Neppelenbroek, Karin Hermana; Lima, Jozely Francisca Mello; Hotta, Juliana; Galitesi, Lucas Lulo; Almeida, Ana Lucia Pompéia Fraga; Urban, Vanessa Migliorini

    2018-02-01

    To investigate the ultimate tensile strength of temporary soft denture liners modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm (SC5314) determined in previous microbiological research. Dumbbell-shaped specimens (n = 7) with a central cross-sectional area of 6 × 3 × 33 mm were produced by Softone and Trusoft, without (control) or with incorporation of drugs in powder form at MICs for C. albicans biofilm (per g of material powder): nystatin (0.032 g), chlorhexidine diacetate (0.064 g), ketoconazole (0.128 g), miconazole (0.256 g), and itraconazole (0.256 g). After plasticization, specimens were immersed in distilled water at 37°C for 24 hours, 7 or 14 days, and then tested in tension in a universal testing machine at 40 mm/min. Data of tensile strength (MPa) and elongation percentage (%) were submitted to 3-way ANOVA and Tukey's test (α = 0.05). At the end of 14 days, the tensile strength for both materials was significantly lower in the groups modified by miconazole and itraconazole compared to the other groups (p < 0.0001), which showed no significant difference between them (p > 0.05). After 7 and 14 days in water, miconazole and itraconazole added into both materials resulted in significantly lower elongation percentages compared to the other antifungal agents and control (p < 0.0001), which were similar to each other (p > 0.05). The addition of the nystatin, chlorhexidine, and ketoconazole at MICs for C. albicans biofilm resulted in no harmful effects on the tensile strength and elongation percentage of the temporary soft denture liner materials up to 14 days. © 2017 by the American College of Prosthodontists.

  12. The effect of thermocycling on tensile bond strength of two soft liners.

    PubMed

    Geramipanah, Farideh; Ghandari, Masoumeh; Zeighami, Somayeh

    2013-09-01

    Failure of soft liners depends mostly on separation from the denture base resin; therefore measurement of the bond strength is very important. The purpose of this study was to compare the tensile bond strength of two soft liners (Acropars, Molloplast-B) to denture base resin before and after thermocycling. Twenty specimens fromeach of the two different soft liners were processed according to the manufacturer's instructions between two polymethyl methacrylate (PMMA) sheets. Ten specimens in each group were maintained in 37°C water for 24 hours and 10 were thermocycled (5000 cycles) among baths of 5° and 55°C. The tensile bond strength was measured using a universal testing machine at a crosshead speed of 5 mm/min. Mode of failure was determined with SEM (magnification ×30). Two-way ANOVA was used to analyze the data. The mean and standard deviation of tensile bond strength of Acropars and Molloplast-B before thermocycling were 6.59±1.85 and1.51±0.22 MPa, respectively and 5.89±1.52 and1.37±0.18 MPa, respectively after thermocycling. There was no significant difference before and after thermocycling. Mode of failure in Acropars and Molloplast-B were adhesive and cohesive, respectivley. The bond strength of Acropars was significantly higher than Molloplast-B (P<0.05).

  13. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.

    PubMed

    De Kok, Ingeborg J; Chang, Kuang-Han; Lu, Tsui-Shan; Cooper, Lyndon F

    2011-01-01

    The mandibular two-implant overdenture has been shown to be a highly successful treatment. However, overdenture patients who desire a fixed prosthesis may not be satisfied with a removable overdenture. This prospective study sought to compare prosthetic outcomes, patient satisfaction, and survival rates of implants between two-implant-supported overdentures (IODs) and three-implant-supported fixed dentures (ISFDs). Twenty completely edentulous patients were randomly and equally assigned to two groups. New conventional complete dentures were made, and the mandibular denture was used as a surgical guide during implant placement. Implants were placed in one stage, followed by a mandibular denture soft reline (provisional loading). Ball attachments were inserted at 8 weeks, and ISFDs were delivered at 16 weeks. IODs were connected to the attachments at 8 weeks, using each patients's existing denture. The definitive ISFDs were fabricated using computer-aided design/computer-assisted manufacture milled titanium frameworks and acrylic resin base and teeth. Patient satisfaction and panoramic radiographs were investigated at 6 and 12 months. Both treatments had significant and positive effects on patient satisfaction and quality of life. None of the 50 implants placed had failed at 12 months of follow-up; therefore, the implant survival rate was 100%. Prosthetic complications were generally rare and easily manageable. Both the treatment modalities-the ISFD supported by three implants and the IOD supported by two implants-significantly and similarly improved patient satisfaction and oral health-related quality of life, and prosthetic complications were relatively rare for both treatments. Three implants can be used to support a mandibular fixed prosthesis; however, a longer observation period is needed to validate this treatment modality.

  14. Inflammatory fibrous hyperplasia treated with a modified vestibuloplasty: a case report.

    PubMed

    Jaimes, Miguel; Muñante, Jose; Olate, Sergio; Rodriguez-Chessa, Jaime Giuseppe; de Albergaria-Barbosa, Jose Ricardo; Mazzonetto, Renato; Klüppel, Leandro Eduardo

    2008-03-01

    The purpose of this report is to present a case of surgical and prosthetic treatment of a woman with inflammatory fibrous hyperplasia (IFH) and her evaluation during a six month period. IFH is a benign pathology, prevalent in female patients, and principally associated with ill-fitting prosthetic devices in need of adjustment. It is common for patients to require surgical removal of the hyperplastic tissue and fabrication of a new prosthesis. A 55-year-old female with a history of smoking presented with a chief complaint of missing the scheduled adjustment of her maxillary complete denture and the presence of moveable tissue under the denture. Surgical excision of the hyperplastic tissue followed with fixation of the prosthesis for six months to guide the healing of the soft tissue and to reshape the contours of the maxillary supporting tissues. Surgical removal of hyperplasic soft tissue is a routine procedure, and the fixation of the prosthesis for the support of tissue during healing improves intraoral conditions for the fabrication of a new prosthesis in the future.

  15. Tunable denture adhesives using biomimetic principles for enhanced tissue adhesion in moist environments.

    PubMed

    Gill, Simrone K; Roohpour, Nima; Topham, Paul D; Tighe, Brian J

    2017-11-01

    Nature provides many interesting examples of adhesive strategies. Of particular note, the protein glue secreted by marine mussels delivers high adhesion in wet and dynamic environments owing to existence of catechol moieties. As such, this study focuses on denture fixatives, where a non-zinc-containing commercial-based formulation has been judiciously modified by a biomimetic catechol-inspired polymer, poly(3,4-dihydroxystyrene/styrene-alt-maleic acid) in a quest to modulate adhesive performance. In vitro studies, in a lap-shear configuration, revealed that the catechol-modified components were able to enhance adhesion to both the denture base and hydrated, functional oral tissue mimic, with the resulting mode of failure prominently being adhesive rather than cohesive. These characteristics are desirable in prosthodontic fixative applications, for which temporary adhesion must be maintained, with ultimately an adhesive failure from the mucosal tissue surface preferred. These insights provide an experimental platform in the design of future biomimetic adhesive systems. Mussel adhesive proteins have proven to be promising biomimetic adhesive candidates for soft tissues and here for the first time we have adapted marine adhesive technology into a denture fixative application. Importantly, we have incorporated a soft tissue mimic in our in vitro adhesion technique that more closely resembles the oral mucosa than previously studied substrates. The novel biomimetic-modified adhesives showed the ability to score the highest adhesive bonding out of all the formulations included in this study, across all moisture levels. This paper will be of major interest to the Acta Biomaterialia readership since the study has illustrated the potential of biomimetic principles in the design of effective prosthodontic tissue adhesives in a series of purpose-designed in vitro experiments in the context of the challenging features of the oral environment. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Treatment of epulis fissuratum with CO2 laser and prosthetic rehabilitation in patients with vesiculobullous disease.

    PubMed

    Işeri, Ufuk; Ozçakir-Tomruk, Ceyda; Gürsoy-Mert, Hare

    2009-08-01

    The purpose of this article is the clinical presentation of the treatment of epulis fissuratum with CO(2) laser and prosthetic rehabilitation of three patients with vesiculobullous diseases (VBDs). Oral problems such as blister formation with minimal trauma are usually encountered in the VBDs. With repeated cycles of blistering and healing, oral hygiene is usually compromised, which leads to rapid breakdown of the dentition. Prosthetic rehabilitation includes complete, partial, and implant-supported dentures; however, ill-fitting dentures can cause inflammatory fibrous hyperplasia. Clinical application of CO(2) laser has been recommended to treat benign oral lesions such as epulis fissuratum and fibroma. The treatment plan consisted of excision of fibrous tissues, controlling dental plaque, and prosthetic rehabilitation. The excision of fibrous tissue was performed with CO(2) laser, and the wounds formed by laser were left open to secondary epithelization. The dental plaque and calculus deposits were cleaned with ultrasonic scalers and a well-formed acrylic denture for maxilla and mandible were fabricated after a month. There was no recurrent fibrous tissue formation at 1 year follow-up. However, plaque accumulation control was unsatisfactory and the patients were therefore urged to undergo a regular 6-month preventive dental prophylaxis regimen and denture re-evaluation. The CO(2) laser may be a useful instrument in the treatment of soft tissue pathologies in VBDs patients due to minimal damage to surrounding tissue. Use of complete or partial dentures has been considered a practical, economic, and nonsurgical treatment option for patients who have been diagnosed with VBDs.

  17. Heat-cured acrylic resin versus light-activated resin: a patient, professional and technician-based evaluation of mandibular implant-supported overdentures.

    PubMed

    Asal, S A; Al-AlShiekh, H M

    2017-12-01

    Although light-activated resins (Eclipse) have been reported to possess superior physical and mechanical properties compared with the heat-cured acrylic resins (Lucitone-199), a few studies have compared overdentures with a locator attachment constructed from heat-cured acrylic resins with those constructed from light-activated resins. This clinical study was designed to compare the performance of a mandibular implant-supported overdenture constructed from a heat-cured acrylic resin (Lucitone-199) with that of an overdenture constructed from a light-activated resin (Eclipse). Ten participants received two identical mandibular implant-retained overdentures (Lucitone-199 and Eclipse) opposing one maxillary denture in a random order. Each mandibular overdenture was delivered and worn for 6 months, and two weeks of rest was advised between wears to minimize any carryover effects. Three questionnaires were devised. The first questionnaire (patient evaluation) focused on evaluating different aspects of the denture and overall satisfaction. The second questionnaire (professional dentist evaluation) was based on a clinical evaluation of soft tissues, complications, and the applied technique. The third questionnaire (technician evaluation) involved ranking the different manufacturing steps of the denture and overall preferences. The obtained data was statistically analyzed using an independent sample t-test and the Wilcoxon rank-sum test. The clinician and technician preferred the Eclipse dentures because of their technical aspects, whereas the patients preferred the Lucitone-199 dentures for their aesthetic properties. Implant-supported overdentures constructed from a heat-cured acrylic resin showed superior aesthetics and had a better odor compared with those constructed from a light-cured resin.

  18. Functional rehabilitation in advanced intraoral cancer.

    PubMed

    Barret, Juan P; Roodenburg, Jan L

    2017-02-01

    Modern treatment of advanced intraoral cancer involves multidisciplinary teams with use of complicated reconstructive techniques to provide improved survival with optimal rehabilitation. Mastication is an important part of this process, and it can be severely impaired by tumor ablation. Whether flap reconstruction is a determinant factor in dental rehabilitation is still in debate. Thirty-five patients with advanced intraoral cancer were reviewed to determine dental rehabilitation of different reconstructive techniques. The patients were treated with a multidisciplinary team approach. The patients' demographics, primary treatment, reconstructive surgery, dental rehabilitation, and functional outcome were recorded and analyzed. Nine patients had Stadium III disease, and 26 patients had stadium IV. Thirty-two patients (91.42%) received postoperative radiotherapy. Masticatory and dental functional rehabilitation of patients was very poor. Only 15 patients (42.86%) could eat a normal diet, whereas 18 patients (51.42%) could manage only soft diets, and 2 patients (5.72%) could only be fed with a liquid diet. Denture rehabilitation was even more frustrating and had a direct impact on masticatory rehabilitation. Only 10 patients (28.57%) could use dentures postoperatively and 40% of patients (14 patients) could not use any denture at all. Above all reconstructive techniques, the free radial forearm flap provides the best functional outcome. Reconstruction of advanced intraoral cancer results in poor denture rehabilitation, especially when bulky flaps are used. If massive resections are necessary, the free radial forearm flap reconstruction provides the best functional outcome.

  19. Comparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distribution.

    PubMed

    Assunção, Wirley Gonçalves; Barão, Valentim Adelino Ricardo; Tabata, Lucas Fernando; de Sousa, Edson Antonio Capello; Gomes, Erica Alves; Delben, Juliana Aparecida

    2009-12-01

    The effect of different mucosa characteristics on stress distribution of complete dentures and overdentures remains unknown. The aim of this study was to evaluate the effect of different mucosa thickness and resiliency on the stress distribution of complete dentures and implant-retained overdentures using a two-dimensional finite element analysis. Representative models of the edentulous mandible were constructed on AutoCAD software according to the groups' characteristics. In group CD, a model of the edentulous mandible supporting a complete denture was obtained while in group IO, a model of edentulous mandible supporting an overdenture over two unsplinted implants with an o' ring system was constructed. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) corresponding to the resiliencies hard, resilient and soft respectively. Evaluation was performed on Ansys software with 100N vertical load applied on central incisor teeth. The principal stress was used as analysis criteria. Group IO showed higher stress values than group CD regardless of mucosal thickness and resiliency. Stress decreased at the supporting tissues in both groups as the thickness and resiliency of mucosa increased. In relation to the supporting tissues, cortical bone showed the highest stress values. It was concluded that the use of an attachment system increases stress values and the thickness and resiliency of mucosa influence more on these values.

  20. The influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge. A 5-year randomised clinical trial.

    PubMed

    Elsyad, M A; Ashmawy, T M; Faramawy, A G

    2014-01-01

    This study aimed to compare the influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge after 5 years of denture wearing. Thirty edentulous male patients (mean age 62·5 years) received two implants in the anterior mandible after being allocated into two equal groups using balanced randomisation. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I, GI) or silicone resilient liners (group II, GII). The prosthetic and soft tissue complications of the maxillary dentures were recorded 6 months (T6 m ), 1 year (T1), 3 years (T3) and 5 years (T5) after overdenture insertion. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 5 years (T5) of overdenture insertion was calculated. Maxillary denture relining times and frequency of flabby anterior maxillary ridge occurred significantly more often in GI compared with GII. The change of R in anterior part of maxilla was significantly higher than change of R in posterior part in both groups. GI showed significant resorption of anterior residual ridge compared with GII. Relining times and frequencies of flabby ridge were significantly correlated with change in R. Within the limitations of this study, resilient liner attachments for bar-implant-retained mandibular overdentures are associated with decreased resorption and flabbiness of maxillary anterior residual ridge and fewer maxillary denture relining times when compared with clip attachments. © 2013 John Wiley & Sons Ltd.

  1. The effect of cleaning substances on the surface of denture base material.

    PubMed

    Žilinskas, Juozas; Junevičius, Jonas; Česaitis, Kęstutis; Junevičiūtė, Gabrielė

    2013-12-11

    The aim of this study was to evaluate the effect of substances used for hygienic cleaning of dentures on the surface of the denture base material. Meliodent Heat Cure (Heraeus-Kulzer, Germany) heat-polymerized acrylic resin was used to produce plates with all the characteristics of removable denture bases (subsequently, "plates"). Oral-B Complete toothbrushes of various brush head types were fixed to a device that imitated tooth brushing movements; table salt and baking soda (frequently used by patients to improve tooth brushing results), toothpaste ("Colgate Total"), and water were also applied. Changes in plate surfaces were monitored by measuring surface reflection alterations on spectrometry. Measurements were conducted before the cleaning and at 2 and 6 hours after cleaning. No statistically significant differences were found between the 3 test series. All 3 plates used in the study underwent statistically significant (p<0.05 changed)--the reflection became poorer. The plates were most affected by the medium-bristle toothbrush with baking soda--the total reflection reduction was 4.82 ± 0.1%; among toothbrushes with toothpaste, the hard-type toothbrush had the greatest reflection-reducing effect--4.6 ± 0.05%, while the toothbrush with table salt inflicted the least damage (3.5 ± 0.16%) due to the presence of rounded crystals between the bristles and the resin surface. Toothbrushes with water had a uniform negative effect on the plate surface - 3.8 9 ± 0.07%. All substances used by the patients caused surface abrasion of the denture base material, which reduced the reflection; a hard toothbrush with toothpaste had the greatest abrasive effect, while soft toothbrushes inflicted the least damage.

  2. Patient-based and clinical outcomes of implant telescopic attachment-retained mandibular overdentures: a 1-year longitudinal prospective study.

    PubMed

    Yunus, Norsiah; Saub, Roslan; Taiyeb Ali, Tara Bai; Salleh, Nosizana Mohd; Baig, Mirza Rustum

    2014-01-01

    The purpose of this study was to evaluate and compare Oral Health-Related Quality of Life (OHRQoL), denture satisfaction, and masticatory performance in edentulous patients provided with mandibular implant-supported overdentures (ISODs) retained with telescopic attachments and those of conventional complete dentures (CCDs). Peri-implant soft tissue changes were also evaluated at various intervals during a 1-year observation period. Participating patients received new CCDs and later received two mandibular interforaminal implants and had their mandibular CCDs converted into ISODs with telescopic attachments. Questionnaires were used to assess OHRQoL (Shortened Oral Health Impact Profile-14, Malaysian version) and denture satisfaction at different stages of treatment with CCDs and ISODs. Objective masticatory performance with the CCDs and ISODs was recorded with a mixing ability test. Evaluations were carried out at 3 months with the new CCDs, 3 months after mandibular ISOD provision, and 1 year after receiving the ISOD. Peri-implant parameters were additionally assessed at specific intervals during the treatment period. The data obtained were statistically analyzed and compared. In the 17 patients who completed the protocol, significant improvements were observed in OHRQoL and patient satisfaction when CCDs were modified to ISODs, after 3 months, and at 1 year. Significantly better mixing ability with the ISOD was noted, with the highest values observed at 1 year. Statistically insignificant differences were observed for all the peri-implant parameters, except for gingival recession, for which significant changes were observed 6 months after ISOD delivery (values had stabilized by 1 year). Telescopic crown attachment-retained mandibular ISODs improved OHRQoL, dental prosthesis satisfaction, and masticatory performance compared to CCDs. Peri-implant soft tissue response and implant stability were found to be favorable after 1 year.

  3. Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review.

    PubMed

    Rutkunas, Vygandas; Mizutani, Hiroshi; Peciuliene, Vytaute; Bendinskaite, Ruta; Linkevicius, Tomas

    2008-01-01

    Research data regarding maxillary complete denture outcome with two-implant supported mandibular overdentures are not consistent. Considering multiple publications on implant supported mandibular overdentures, it was decided to summarize currently present evidence on the maxillary complete dentures opposed by implant-supported mandibular overdentures, and analyze factors that could potentially influence the outcomes. The articles from 1985 to 2007 related to the topic were identified in the online MEDLINE/Pubmed and other databases and manually. Primary articles were scanned, and irrelevant studies were excluded from the further review process. Potentially relevant titles and abstracts were provisionally included for consideration on the basis of full text articles. Full text articles were obtained from on-line and printed sources. The data from the studies were extracted and reviewed. The study has failed to identify any prospective satisfying inclusion/exclusion criteria RCT reporting on maxillary bone resorption. The number of maxillary complete denture relining incidences per patient was constantly increasing during the 10-year period. Maxillary complete denture remake incidences comprised 16-33 % of the number of patients followed during the 10-year period. Comparing patient satisfaction with upper dentures at the baseline and after two years, no decrease in satisfaction was noticed. There is no evidence that maxillary ridge resorption is accelerated with certain types of two-implant supported mandibular overdenture attachments. Most common complication for the maxilla - prosthetic maintenance. There is a risk of decreased patient satisfaction with bar-supported mandibular overdenture. Further studies are needed to provide evidence for the maxillary complete denture outcome with two-implant supported mandibular overdentures.

  4. Support Ratio Between Abutment and Soft Tissue Under Overdentures: A Comparison Between Use of Two and Four Abutments.

    PubMed

    Abe, Manami; Yang, Tsung-Chieh; Maeda, Yoshionobu; Ando, Takanori; Wada, Masahiro

    The purpose of this preliminary in vivo study was to compare force distribution on abutments (tooth or implant) and tissues supporting overdentures with two or four abutments. A convenience sample of five subjects with tooth and/or implant-supported overdentures was enrolled. Recordings were completed on each subject using a force-measuring system mounted on a metal framework with four anteroposterior spread abutments (A), four abutments with denture bases (B), and on two anterior abutments with denture bases (C). The tissue-support ratio (TSR) was calculated as (A-B)/A or (A-C)/A. TSR values changed 1.5 to 2 times when the number of abutments was reduced from four to two. The amount of tissue strain on the posterior residual ridge increased when the number of abutments was reduced.

  5. Functional rehabilitation in advanced intraoral cancer

    PubMed Central

    Roodenburg, Jan L.

    2017-01-01

    Introduction: Modern treatment of advanced intraoral cancer involves multidisciplinary teams with use of complicated reconstructive techniques to provide improved survival with optimal rehabilitation. Mastication is an important part of this process, and it can be severely impaired by tumor ablation. Whether flap reconstruction is a determinant factor in dental rehabilitation is still in debate. Patients and methods: Thirty-five patients with advanced intraoral cancer were reviewed to determine dental rehabilitation of different reconstructive techniques. The patients were treated with a multidisciplinary team approach. The patients’ demographics, primary treatment, reconstructive surgery, dental rehabilitation, and functional outcome were recorded and analyzed. Results: Nine patients had Stadium III disease, and 26 patients had stadium IV. Thirty-two patients (91.42%) received postoperative radiotherapy. Masticatory and dental functional rehabilitation of patients was very poor. Only 15 patients (42.86%) could eat a normal diet, whereas 18 patients (51.42%) could manage only soft diets, and 2 patients (5.72%) could only be fed with a liquid diet. Denture rehabilitation was even more frustrating and had a direct impact on masticatory rehabilitation. Only 10 patients (28.57%) could use dentures postoperatively and 40% of patients (14 patients) could not use any denture at all. Above all reconstructive techniques, the free radial forearm flap provides the best functional outcome. Conclusions: Reconstruction of advanced intraoral cancer results in poor denture rehabilitation, especially when bulky flaps are used. If massive resections are necessary, the free radial forearm flap reconstruction provides the best functional outcome. PMID:29177211

  6. Study on digital teeth selection and virtual teeth arrangement for complete denture.

    PubMed

    Yu, Xiaoling; Cheng, Xiaosheng; Dai, Ning; Chen, Hu; Yu, Changjiang; Sun, Yuchun

    2018-03-01

    In dentistry, the complete denture is a conventional treatment for edentulous patients. The computer-aided design and computer-aided manufacturing (CAD/CAM) has been applied on the digital complete denture which is developed rapidly. Tooth selection and arrangement is one of the most important parts in digital complete denture. In this paper, we propose a new method of personalized teeth arrangement. This paper presents a method of arranging teeth virtually for a complete denture. First, scan and extract the feature points of the 3D triangular mesh data of artificial teeth (PLY format), then establish a tooth selection system. Second, scan and mark the anatomic characteristics of the maxillary and mandibular cast surfaces, such as facial midline, the curve of the arches. With the enter information, the study calculates the common arrangement lines of artificial teeth. Third, select the preferred artificial teeth and automatically arrange them virtually in the correct position by using our own software. After that, design the gingival part of the dentures on the basic of the arranged teeth on the screen and then fabricated it by using Computerized Numerical Control (CNC) technology, Rapid Prototyping (RP) technology or 3D printer technology. Finally, select artificial teeth were embedded in wax rims. This system can choose artificial teeth reasonably and the teeth placement can meet the dentist's request to a certain extent, whereas all the operations are based on the medical principles. The study performed here involves computer sciences, medicine, and dentistry, a teeth selection system was proposed and virtual teeth arrangement was described. This study has the capacity of helping operators to select teeth, which improved the accuracy of tooth arrangement, and customized complete denture. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Patient satisfaction and prosthetic aspects with mini-implants retained mandibular overdentures. A 5-year prospective study.

    PubMed

    Elsyad, Moustafa Abdou

    2016-07-01

    This study aimed to evaluate patient satisfaction and prosthetic aspects during a 5-year prospective clinical study of mini dental implants (MDIs) retaining mandibular overdentures. This observational prospective clinical study was conducted on a group of completely edentulous patients (n = 28) with retention problems of conventional mandibular dentures. All patients received new maxillary and mandibular conventional dentures. A total of 112 MDIs (four per patient) were inserted using the flapless surgical approach and immediately loaded by the new mandibular dentures (overdentures). Patients indicated satisfaction with their prosthesis using a questionnaire and a visual analogue scale (VAS). Patient satisfaction and prosthetic complications were recorded 6 months (T6 m ), 1 (T1), 3 (T3), and 5 (T5) years after overdenture insertion. The patient satisfaction with eating (hard/soft) food (P < 0.001), talking (P < 0.001), appearance (P = 0.001), comfort (P < 0.001), healing process (P = 0.013), socialization (P < 0.001), stability/retention of mandibular dentures (P = 0.001), ease of oral hygiene (P = 0.008), and ease of handling the dentures (P < 0.001) increased significantly with time. After 5 years, the most common complication was wear/damage of O/rings (n = 235), O/ring replacement (n = 125), maxillary denture relining times (n = 13), worn teeth (n = 10), overdentures relines (n = 10), detachment of the metal housings (n = 9), and fracture of mandibular overdentures (n = 8). Mucositis, soreness, and decubitis ulcer under overdenture occurred most often at T6 m and decreased significantly with time (P = 0.002, 0.005, and 0.024, respectively). Within the limitations of this clinical study, patient satisfaction with mini-implant retained mandibular overdentures increased significantly with time. However, this treatment required a considerable amount of prosthetic maintenance and repair after 5 years of service. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Prosthetic rehabilitation of a marginally resected mandibular arch with a metal reinforced telescopic overdenture.

    PubMed

    Rohit, Raghavan; Prathith, Uthappa; Regish, K M; Rupesh, P L; Basavaraj, Salagundi; Padmanabhan, T V

    2014-09-01

    Success of the prosthesis after mandibular resection is related directly to the amount of the remaining bone and soft tissue present. The prognosis for mandibulectomy patients becomes less favorable as the size of the resection increases. Prosthetic rehabilitation for such patients is a challenge for clinicians. Without preprosthetic reconstructive surgery, denture fabrication for mandibulectomy patients becomes extremely difficult. Telescopic dentures is a modality of treatment consisting of an inner or primary telescopic coping which is permanently cemented to an abutment and an outer or secondary telescopic coping which is attached to the prosthesis. These copings protect the abutment from dental caries and thermal irritations and also provide retention and stabilization of the secondary coping. The secondary coping engages the primary copings to form a telescopic unit and it provides retention and stability to the prosthesis. This clinical report aims at utilizing the remaining natural teeth for a mandibular overdenture with telescopic coping.

  9. Management of denture-induced epulis fissuratum with Er,Cr:YSGG laser: a case report

    NASA Astrophysics Data System (ADS)

    Koli, Dheeraj Kumar; Gupta, Manak; Verma, Mahesh; Lamba, Arundeep Kaur; Chawla, Kirti

    2012-01-01

    Epulis fissuratum refers to tissue growth into the oral cavity, located over the alveolar ridges or the soft tissues of the vestibular sulcus. Trauma and irritation are important aetiological factors for epulis fissuratum and lesions arise in areas of persistent mucosal injury. This report presents a case of a 68-year old male patient with two soft tissue hyperplastic growths seen in the buccal vestibule in the lower anterior region. These lesions were removed using an Er,Cr:YSGG laser. The healing was uneventful and no suture or analgesic was required. The histopathological report confirmed the presurgical diagnosis. No relapse was observed till one year after surgery.

  10. Selected applications for current polymers in prosthetic dentistry - state of the art.

    PubMed

    Kawala, Maciej; Smardz, Joanna; Adamczyk, Lukasz; Grychowska, Natalia; Wieckiewicz, Mieszko

    2018-05-10

    Polymers are widely applied in medicine, including dentistry, i.e. in prosthodontics. The following paper is aimed at demonstrating the applications of selected modern polymers in prosthetic dentistry based on the reported literature. The study was conducted using the PubMed, SCOPUS and CINAHL databases in relation to documents published during 1999-2017. The following keywords were used: polymers with: prosthetic dentistry, impression materials, denture base materials, bite registration materials, denture soft liners, occlusal splint materials and 3D printing. Original papers and reviews which were significant from the modern clinical viewpoint and practical validity in relation to the possibility of using polymeric materials in prosthetic dentistry, were presented. Denture base materials were most commonly modified polymers. Modifications mainly concerned antimicrobial properties and reinforcement of the material structure by introducing additional fibers. Antimicrobial modifications were also common in case of relining materials. Polymeric materials have widely been used in prosthetic dentistry. Modifications of their composition allow achieving new, beneficial properties that affect quality of patients' life. Progress in science allows for a more methodologically-advanced research on the synthesis of new polymeric materials and incorporation of new substances into already known polymeric materials, that will require systematization and appropriate classification. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. A sectional denture as the optimal prosthesis.

    PubMed

    Cohen, K

    1989-08-01

    A case is described where because of various local factors--anterior ridge loss, Class III skeletal relationship, survey lines, appearance, retention and support problems--a sectional prosthesis was found to be the optimal restoration.

  12. Influence of the mechanical properties of resilient denture liners on the retention of overdenture attachments.

    PubMed

    Kubo, Keitaro; Koike, Takashi; Ueda, Takayuki; Sakurai, Kaoru

    2018-03-15

    Information is lacking about the selection criteria for silicone resilient denture liners applied as a matrix material for attachments on overdentures. The purpose of this in vitro study was to investigate the mechanical properties of silicone resilient denture liners and their influence on the initial retention force of overdenture attachments and the reduction in retention force over time. Nine types of silicone resilient denture liner were injected and fixed to the matrix section of an experimental denture base. They were then fitted to an epoxy resin model that simulated the residual ridge with a patrix ball attachment (n=10). The retention force of the denture was measured with a digital force gauge, and the maximum force of traction (N) was regarded as the initial retention force. The retention force reduction (N) after repeated insertion and removal (n=5) was calculated by subtracting the retention force after 3348 cycles (3-year simulated insertion and removal) from the initial retention force. The intaglio of the matrix was observed with a scanning electron microscope (SEM) before and after the 3348 cycles. Four mechanical properties (hardness, strain-in-compression, tensile strength, and arithmetic mean roughness) of the resilient denture liners were measured. One-way ANOVA of the initial retention force of each lining material was performed, followed by the Scheffe test (α=.05). Pearson correlation analysis was used (α=.05) to analyze correlations of the initial retention force with the retention force reduction after insertion and removal and the mechanical properties of each material. Multiple regression analysis with the stepwise method extracted the initial retention force and the retention force reduction as dependent variables, and the resilient denture liner mechanical properties as explanatory variables (α=.05). The initial retention force of the resilient denture liners was 1.3 to 5.4 N. Multiple comparisons showed significant differences in some groups (P<.05). The retention force reduction of the resilient denture liners was 0.2 to 1.9 N. Multiple regression analysis with the stepwise method extracted hardness and strain-in-compression as explanatory variables for the initial retention force and the retention force reduction. Within the limitations of this in vitro study, we found that hardness influenced the initial retention force of the overdenture, and that strain-in-compression influenced the retention force reduction in the 3-year simulation. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Prosthetic aspects and patient satisfaction with resilient liner and clip attachments for bar- and implant-retained mandibular overdentures: a 3-year randomized clinical study.

    PubMed

    ELsyad, Moustafa Abdou

    2012-01-01

    This report aimed to compare prosthetic aspects and patient satisfaction during a 3-year randomized clinical trial of bar- and implant-retained mandibular overdentures attached with either resilient liners or clips. Thirty edentulous male patients (mean age: 62.5 years) received two implants in the anterior mandible after being allocated into two equal groups (according to attachment type received) using balanced randomization. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I) or silicone resilient liners (group II). Subjects indicated satisfaction with their prostheses using a questionnaire and visual analog scale. Patient satisfaction and prosthetic complications were recorded for both attachments at 6 months and 1 and 3 years after overdenture insertion. Comfort and stability with the maxillary denture and ease of hygiene procedures were rated higher in group II, while ease of handling the dentures was rated higher in group I. No significant differences in other parameters of patient satisfaction between groups were noted after 3 years. The mean number of prosthetic adjustments and repairs in group I (11.9) was significantly higher (P = .00) compared to that in group II (4.8). The most common complication in group I was clip wear, while separation of the resilient liner from the denture base was the most common problem in group II. Hyperplasia under the bar and flabby ridge in the maxilla occurred significantly more often in group I compared to group II. Resilient liner-retained mandibular overdentures had comparable patient satisfaction, less prosthetic maintenance and costs, and less soft tissue complications when compared to clip-retained ones after 3 years.

  14. Influence of storage methods on the surface roughness of tissue conditioners.

    PubMed

    Hong, Guan; Li, YingAi; Maeda, Takeshi; Mizumachi, Wataru; Sadamori, Shinsuke; Hamada, Taizo; Murata, Hiroshi

    2008-03-01

    The purpose of this study was to compare the influence of three kinds of storage methods on surface roughness of tissue conditioners. Four commercial tissue conditioners (GC Soft Liner, Softone, Fictioner, and Hydro-Cast) were used in this study. Five samples of each material were stored in distilled water, air, and a denture cleanser (Polident). Mean surface roughness (R(a)) values of dental stone casts made from the tissue conditioners were measured after 0, 1, 3, 7, and 14 days of immersion using a profilometer. Significant differences in the R(a) values of the specimens were found among the three storage methods. The values of R(a) significantly increased with increase in immersion time for each storage method, except for the materials stored in air. It was found that the materials stored in air showed the most stable and lowest values of R(a). Results obtained suggested that a tissue conditioner exhibited smooth and minimal change in surface roughness with time when stored in air than in distilled water and denture cleanser.

  15. Oral mucosal lesions in denture wearers.

    PubMed

    Jainkittivong, Aree; Aneksuk, Vilaiwan; Langlais, Robert P

    2010-03-01

    To determine the prevalence of oral mucosal lesions (OMLs) and denture-related mucosal lesions (DMLs) in denture wearers and to co-relate the prevalence with age, gender, type of denture and any systemic conditions. Dental records of 380 denture wearers were retrospectively reviewed for OMLs and DMLs. We found 45% of the denture wearers had DMLs and 60.8% had OMLs not related to denture wearing. Although the prevalence of DMLs was higher in complete denture wearers than in partial denture wearers (49% vs. 42.2%), this difference was not significant. The most common DMLs were traumatic ulcer (19.5%) and denture-induced stomatitis (18.1%). When analysed by type, traumatic ulcer, denture hyperplasia, frictional keratosis and candidiasis were more common in complete denture wearers, whereas denture-induced stomatitis was more common in partial denture wearers. Frictional keratosis was more common in men than in women. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers, and the most common OML was fissured tongue (27.6%). No association between DMLs and systemic conditions or xerostomic drugs was noted. No differences in the prevalence of DMLs in association with denture type were found. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers. This difference was affected by age, and the data were similar to the findings observed in the elderly.

  16. Do CAD/CAM dentures really release less monomer than conventional dentures?

    PubMed

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  17. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report.

    PubMed

    Tasopoulos, Theodoros; Kouveliotis, Georgios; Polyzois, Grigoris; Karathanasi, Vasiliki

    2017-03-01

    Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA) offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heat-cured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration.

  18. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report

    PubMed Central

    Kouveliotis, Georgios; Polyzois, Grigoris; Karathanasi, Vasiliki

    2017-01-01

    Introduction Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA) offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. Clinical case A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heat-cured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Conclusion Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration. PMID:28740271

  19. In vitro comparison of implant- versus gingiva-supported removable dentures in anterior and posterior applications.

    PubMed

    Rosentritt, Martin; Heidtkamp, Felix; Hösl, Helmut; Hahnel, Sebastian; Preis, Verena

    2016-03-01

    Removable dentures with different denture teeth may provide different performance and resistance in implant and gingival situations, or anterior and posterior applications. Two situations of removable dentures were investigated: gingiva (flexible) and implant (rigid) bearing. For simulating the gingiva/jaw situation, the dentures were supported with flexible lining material. For the implant situation, implants (d = 4.1 mm) were screwed into polymethylenmethacrylate (PMMA) resin. Two commercial (Vita-Physiodens MRP, SR Vivodent/Orthotyp DCL) and two experimental materials (EXP1, EXP2) were investigated in anterior (A) and posterior (P) tooth locations. Chewing simulation was performed, and failures were analyzed (microscopy, SEM). Fracture strength of surviving dentures was determined. Only EXP1 revealed failures during chewing simulation. Failures varied between anterior and posterior locations, and between implant (P:4x; A:7x) or gingiva (P:1x; A:2x) situations. Kaplan-Meier log-rank test revealed significant differences for implant situations (p < 0.002), but not for gingiva bearing (p > 0.093). Fracture testing in the implant situation provided significantly highest values for EXP2 (1476.4 ± 532.2 N) in posterior location, and for DCL (1575.4 ± 264.4 N) and EXP2 (1797.0 ± 604.2 N) in anterior location. For gingival bearing, significantly highest values were found for DCL/P (2148.3 ± 836.3 N), and significantly lowest results for EXP1/A (308.2 ± 115.6 N). For EXP1 + EXP2 + Vita/P and for EXP1/A no significant differences were found between implant- or gingiva-supported situations. Anterior and posterior teeth showed different material-dependent in vitro performance, further influenced by implant/gingiva bearing. While an implant in anterior application increased fracture strength of two materials, it decreased fracture values of 3/4 of the materials in posterior application. Survival of denture teeth may be influenced by material, oral position, and bearing situation.

  20. CAD/CAM produces dentures with improved fit.

    PubMed

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  1. Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures.

    PubMed

    Stawarczyk, Bogna; Lümkemann, Nina; Eichberger, Marlis; Wimmer, Timea

    2017-12-19

    The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL)-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D) software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x -, y - and z -axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the vicinity of the denture teeth area and the bases. The conventional transfer of CAD/CAM-fabricated wax dentures into acrylic resin leads to the highest deviations from the STL-reference.

  2. Do flexible acrylic resin lingual flanges improve retention of mandibular complete dentures?

    PubMed Central

    Ahmed Elmorsy, Ayman Elmorsy; Ahmed Ibraheem, Eman Mostafa; Ela, Alaa Aboul; Fahmy, Ahmed; Nassani, Mohammad Zakaria

    2015-01-01

    Objectives: The aim of this study was to compare the retention of conventional mandibular complete dentures with that of mandibular complete dentures having lingual flanges constructed with flexible acrylic resin “Versacryl.” Materials and Methods: The study sample comprised 10 completely edentulous patients. Each patient received one maxillary complete denture and two mandibular complete dentures. One mandibular denture was made of conventional heat-cured acrylic resin and the other had its lingual flanges made of flexible acrylic resin Versacryl. Digital force-meter was used to measure retention of mandibular dentures at delivery and at 2 weeks and 45 days following denture insertion. Results: The statistical analysis showed that at baseline and follow-up appointments, retention of mandibular complete dentures with flexible lingual flanges was significantly greater than retention of conventional mandibular dentures (P < 0.05). In both types of mandibular dentures, retention of dentures increased significantly over the follow-up period (P < 0.05). Conclusions: The use of flexible acrylic resin lingual flanges in the construction of mandibular complete dentures improved denture retention. PMID:26539387

  3. Perception of Esthetic Impact of Smile Line in Complete Denture Wearers by Different Age Groups.

    PubMed

    Pithon, Matheus Melo; Alves, Leandro Pereira; da Costa Prado, Matheus; Oliveira, Rener Leal; Costa, Matheus Souza Campos; da Silva Coqueiro, Raildo; Gusmão, João Milton Rocha; Santos, Rogério Lacerda

    2016-10-01

    To evaluate esthetic perceptions based on tooth exposure when smiling of patients wearing complete dentures by evaluators in different age groups. Alterations were made to a front view photograph of a smiling patient wearing complete maxillary and mandibular dentures. Alterations in the smile line were simulated to increase or decrease tooth exposure (increments of 0.5 mm). For this purpose, image manipulation software was used. After manipulation, images were printed on photo paper, attached to a questionnaire, and distributed to individuals in three age groups (n = 150). To evaluate the esthetic perception for each image, a visual analog scale was used, with 0 representing least attractive, 5 representing attractive, and 10 representing very attractive. Differences between examiners were analyzed using the Mann-Whitney test. All statistical analyses were performed with a degree of confidence of 95%. Two evaluators did not observe any differences between images. The images given the best and worst scores were E and O (alterations of 2 and 7 mm), respectively, in the 15- to 19-year-old group, B and O (alterations of 0.5 and 7 mm), respectively, in the 35- to 44-year-old group, and A and M (no alteration and 6 mm alteration), respectively, in the 65- to 74-year-old group. When the images were presented together (images 1 and 2), the unaltered image was selected by individuals of different age groups as the best, and the image with a change of 7 mm was selected as the worst. In this study, complete dental prostheses with smile lines that coincided with the cervical margins of the anterior teeth were the most acceptable. Less exposure of the maxillary teeth when smiling corresponded with decreased attractiveness. © 2015 by the American College of Prosthodontists.

  4. A clinical study to evaluate denture adhesive use in well-fitting dentures.

    PubMed

    Munoz, Carlos A; Gendreau, Linda; Shanga, Gilbert; Magnuszewski, Tabetha; Fernandez, Patricia; Durocher, John

    2012-02-01

    The objective of this study was the assessment of retention and stability and functional benefits of denture adhesive applied to well-fitting and well-made dentures. This was a randomized, crossover study to compare two marketed denture adhesives (test cream, Super Poligrip® Free, and test strip, Super Poligrip® Comfort Seal Strips) and an unmarketed cream adhesive (GlaxoSmith Kline Consumer Healthcare) with no adhesive as the negative control. Thirty-six subjects completed the study. One hour after the application of denture adhesive, retention and stability were measured using the Kapur Index and maxillary incisal bite force. Two hours after application, functional tests were used to assess denture movement and peanut particle migration under the denture. Subjects also rated confidence, comfort, satisfaction with dentures, and denture wobble in conjunction with the functional tests. Denture adhesives significantly (p < 0.05) improved retention and stability of well-fitting dentures. Subjects experienced significantly (p < 0.05) fewer dislodgements while eating an apple after adhesive was applied to dentures. Significant (p < 0.05) increases in subjective ratings of confidence and comfort as well as decreases in denture wobble were associated with the use of adhesive. There was significant (p < 0.05) improvement in satisfaction ratings for cream adhesives. A single application of each denture adhesive was well tolerated. The results of this study provide evidence that use of Super Poligrip® denture adhesives can enhance aspects of performance of complete well-fitting dentures as well as provide increased comfort, confidence, and satisfaction with dentures. © 2011 by the American College of Prosthodontists.

  5. Impact of removable dentures on oral health-related quality of life among elderly adults in Taiwan.

    PubMed

    Yen, Yea-Yin; Lee, Huey-Er; Wu, Yi-Min; Lan, Shou-Jen; Wang, Wen-Chen; Du, Je-Kang; Huang, Shun-Te; Hsu, Kun-Jung

    2015-01-05

    Although the use of removable dentures can improve oral function and esthetics for elderly people, compared to those who do not wear removable dentures, those wearing removable dentures could have worse oral health related-quality of life (OHRQoL). Additional information is required to assess which factors related to denture wearing influence the OHRQoL of elderly individuals. The purpose of this study is to evaluate the association between denture wearing and OHRQoL in a sample of elderly individuals in Taiwan. The study population included 277 elderly people wearing removable dentures (mean age = 76.0 years). Using face-to-face interviews, we collected data on the participants' socio-demographic characteristics, dental care service usage (regular dental checkups, treatment during toothache, dental visits in the last year), and factors related to denture wearing (perceived oral pain, perceived loose denture, perceived oral ulcer, perceived halitosis, perceived dry mouth, and perceived total denture satisfaction scores). OHRQoL was measured using the Taiwanese version of the Geriatric Oral Health Assessment Index (GOHAI-T). The location and number of remaining natural teeth and the type of denture were also recorded. Hierarchical multiple regression analysis was performed using GOHAI-T scores as the dependent variable. All the predictors together accounted for 50% of the variance in GOHAI-T scores. Further, education level, number of natural teeth, denture status, perceived loose denture, perceived oral ulcer, and perceived total denture satisfaction scores had statistically significant influences on OHRQoL. When compared with other variables, factors related to denture wearing, especially perceived total denture satisfaction scores, had the greatest impact on GOHAI-T scores. Of the factors analyzed in this study, denture satisfaction was the strongest predictor of OHRQoL. This suggests that denture satisfaction is useful for assessing the effect of denture treatment on the OHRQoL of elderly individuals wearing removable dentures.

  6. Evaluation of the efficiency of denture cleaners for removing denture adhesives.

    PubMed

    Harada-Hada, Kae; Hong, Guang; Abekura, Hitoshi; Murata, Hiroshi

    2016-12-01

    We developed a new scoring index for assessing the removability of denture adhesives and evaluated the removal efficiency of denture cleaners. Although our understanding of the importance of denture care is increasing, little is known about the effectiveness and efficiency of denture cleaners on denture adhesives. Therefore, guidelines for proper cleaning are necessary. We used five denture cleaner solutions on two cream adhesives, one powder adhesive and one cushion adhesive. After immersion in the denture cleaners for a designated time, we evaluated the area of the sample plate still covered by denture adhesive. Cream adhesives were removed more completely after immersion in majority of the denture cleaners than in water. Powder adhesive was removed more quickly than cream adhesives. Cushion adhesive was not removed by immersion in either the denture cleaners or water control. Some denture cleaners could liquefy cream adhesives more than water, but these differences were not observed in case of powder and cushion adhesives. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  7. Cytocompatible antifungal acrylic resin containing silver nanoparticles for dentures

    PubMed Central

    Acosta-Torres, Laura Susana; Mendieta, Irasema; Nuñez-Anita, Rosa Elvira; Cajero-Juárez, Marcos; Castaño, Víctor M

    2012-01-01

    Background Inhibition of Candida albicans on denture resins could play a significant role in preventing the development of denture stomatitis. The safety of a new dental material with antifungal properties was analyzed in this work. Methods Poly(methyl methacrylate) [PMMA] discs and PMMA-silver nanoparticle discs were formulated, with the commercial acrylic resin, Nature-CrylTM, used as a control. Silver nanoparticles were synthesized and characterized by ultraviolet-visible spectroscopy, dispersive Raman spectroscopy, and transmission electron microscopy. The antifungal effect was assessed using a luminescent microbial cell viability assay. Biocompatibility tests were carried out using NIH-3T3 mouse embryonic fibroblasts and a Jurkat human lymphocyte cell line. Cells were cultured for 24 or 72 hours in the presence or absence of the polymer formulations and analyzed using three different tests, ie, cellular viability by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, and cell proliferation by enzyme-linked immunosorbent assay BrdU, and genomic DNA damage (Comet assay). Finally, the samples were evaluated mechanically, and the polymer-bearing silver nanoparticles were analyzed microscopically to evaluate dispersion of the nanoparticles. Results The results show that PMMA-silver nanoparticle discs significantly reduce adherence of C. albicans and do not affect metabolism or proliferation. They also appear not to cause genotoxic damage to cells. Conclusion The present work has developed a new biocompatible antifungal PMMA denture base material. PMID:22969297

  8. IMPROVDENT: improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures.

    PubMed

    Gray, Janine C; Navarro-Coy, Nuria; Pavitt, Sue H; Hulme, Claire; Godfrey, Mary; Craddock, Helen L; Brunton, Paul A; Brown, Sarah; Dillon, Sean; Dukanovic, Gillian; Fernandez, Catherine; Wright, Jonathan; Collier, Howard; Swithenbank, Shirley; Lee, Carol; Hyde, T Paul

    2012-08-31

    According to the UK Adult Dental Health Survey (2009) 15% of adults aged 65-74, 30% aged 75-84 and 47% aged >85 years are edentulous and require complete dentures. Patients' quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone). Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period). Patients will then wear each set of dentures for a period of 8 weeks (in random order) during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period).Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference) and confirmation period (adjusted denture preference). A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300). This trial aims to provide evidence on the costs and quality of dentures cast from two different commonly used impression materials; the intention is to significantly impact on the quality of denture production within NHS dentistry. ISRCTN Register: ISRCTN01528038 UKCRN Portfolio ID: 8305.

  9. Dental health professional recommendation and consumer habits in denture cleansing.

    PubMed

    Axe, Alyson S; Varghese, Roshan; Bosma, MaryLynn; Kitson, Nicola; Bradshaw, David J

    2016-02-01

    Regular cleaning of dentures is essential to the oral and general health of denture wearers. Only limited systematic data are available on the recommendations that dental health care professionals (DHCPs) make to patients for denture cleaning. Data on denture wearers' cleaning regimens are also lacking. The purpose of this study was to provide data on recommendations that DHCPs make to patients for denture cleaning and on the cleaning regimens of denture wearers. DHCPs (n=613), including dentists and hygienists, were surveyed in developed (Japan, USA, Italy) and developing (Brazil, India) countries. A questionnaire assessing a range of denture cleaning recommendations was used. The questions addressed products, frequency, how to use remedies, the suggested dilution and duration of cleansing treatment, the location of dentures while cleaning, and the reasoning behind the recommendation of particular products or modes of treatment. Denture cleansing methods and the routine of denture wearers in developed and developing countries were also surveyed with a questionnaire (n=2862) and a 1-week diary (n=1462). An average of more than 2 treatments was recommended by DHCPs. Specialist denture cleanser tablets, "regular" toothpaste, mouthwash, soap and water, denture paste, foam or liquid denture cleanser, and dishwashing detergents were most commonly recommended; other product recommendations included baking soda, vinegar, salt water, and bleach. More than 10% of DHCPs made no primary recommendation on cleaning. Denture tablets were more commonly recommended in developed countries, whereas toothpaste was the most common recommendation in developing countries. Denture wearers used products and methods similar to those recommended by DHCPs. Toothpaste, water, and mouthwash were used more frequently than denture tablets. More than 75% of denture wearers reported using denture cleanser tablets for more than 5 minutes, whereas soap and toothpaste were typically used for less than 2 minutes. DHCP recommendations and denture wearer habits are diverse, with no consensus on the most appropriate denture cleaning methods. This reflects a lack of clear, systematic evidence upon which to base recommendations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Taste acuity of the human palate. III. Studies with taste solutions on subjects in different age groups.

    PubMed

    Nilsson, B

    1979-01-01

    The taste acuity at the midline of the hard and soft palate near their junction and, for comparison, on representative areas of the tongue was determined in 80 subjects aged 11-79 years by applying test solutions of the four basic tastes. Twenty-one subjects (26%) could identify at least one taste on the hard palate but none could recognize all four tastes. Seventy subjects (87%) could identify at least one taste on the soft palate and 37 subjects (46%) could recognize all four tastes. Taste thresholds were much higher on the hard palate than on the tongue and were in most cases higher on the soft palate than on the tongue. The ability to recognize all four tastes was less frequent in older than in younger subjects and the difference was greatest on the soft palate and least at the foliate papillae. The differences were greatest for citric acid and least for sucrose. There was a tendency to lower thresholds for women compared to men for all four tastes on all areas examined which was most pronounced on the soft palate. No differences in taste thresholds were found between denture wearers and subjects with natural dentition. Smokers had higher thresholds than non-smokers only for salt on the soft palate and the base of the tongue.

  11. Influence of psychological factors on the acceptance of complete dentures.

    PubMed

    al Quran, F; Clifford, T; Cooper, C; Lamey, P J

    2001-07-01

    To assess the influence of psychological factors on the acceptance of complete dentures in a population wearing dentures judged to be clinically satisfactory. Subjects were asked to complete personality profiles and also to rate their dentures using a denture satisfaction questionnaire. The survey was conducted in the prosthetics clinic of a teaching hospital. Patients were selected from those who had new complete dentures constructed in the department within the previous two years. The personality inventory was a self-administered questionnaire comprising 240 items covering the five domains of personality. Denture satisfaction was scored on a nine item scale with four Likert type responses to each. A group of 16% consistently complained about their dentures. Statistical analysis showed that personality factors especially Neuroticism had a significant relationship with denture satisfaction. Psychological factors significantly influence denture satisfaction and profiles may provide useful in predicting potential difficult denture wearers.

  12. Determination of oral mucosal Poisson's ratio and coefficient of friction from in-vivo contact pressure measurements.

    PubMed

    Chen, Junning; Suenaga, Hanako; Hogg, Michael; Li, Wei; Swain, Michael; Li, Qing

    2016-01-01

    Despite their considerable importance to biomechanics, there are no existing methods available to directly measure apparent Poisson's ratio and friction coefficient of oral mucosa. This study aimed to develop an inverse procedure to determine these two biomechanical parameters by utilizing in vivo experiment of contact pressure between partial denture and beneath mucosa through nonlinear finite element (FE) analysis and surrogate response surface (RS) modelling technique. First, the in vivo denture-mucosa contact pressure was measured by a tactile electronic sensing sheet. Second, a 3D FE model was constructed based on the patient CT images. Third, a range of apparent Poisson's ratios and the coefficients of friction from literature was considered as the design variables in a series of FE runs for constructing a RS surrogate model. Finally, the discrepancy between computed in silico and measured in vivo results was minimized to identify the best matching Poisson's ratio and coefficient of friction. The established non-invasive methodology was demonstrated effective to identify such biomechanical parameters of oral mucosa and can be potentially used for determining the biomaterial properties of other soft biological tissues.

  13. Dentist-Patient Communication and Denture Quality Associated with Complete Denture Satisfaction Among Taiwanese Elderly Wearers.

    PubMed

    Chen, Jen-Hao; Huang, Hsiao-Ling; Lin, Ying-Chun; Chou, Tsau-Mau; Ebinger, John; Lee, Huey-Er

    2015-01-01

    The aim of this study was to explore individual (ie, sociodemographic characteristics, patient personality) and clinical factors (ie, dentist-patient communication, denture quality) associated with complete denture satisfaction among the Taiwanese elderly population. A multistage sampling and cross-sectional design was used to collect data. A total of 387 fully edentulous citizens, aged 65 years and older and who had received new sets of complete dentures, were selected. The participants completed clinical dental examinations and questionnaires by personal interview to collect information on denture satisfaction and associated variables. The relationship among three groups of these participants (satisfied, neutral, and dissatisfied) and potential factors were simultaneously examined using polytomous logistic regression analysis. Overall, 36.7% of the participants were dissatisfied with their dentures. Living status (crude odds ratio [COR] = 2.04), personality (COR = 4.86), dentist-patient communication (COR = 7.46), and denture quality (COR = 5.02) were associated with complete denture satisfaction. The multivariate regression model showed that dentist-patient communication (adjusted odds ratio [AOR] = 6.41) and denture quality (AOR = 4.40) were significant complete denture satisfaction factors that diluted the effect of living status and personality. Inadequate dentistpatient communication and low denture quality were associated with the dissatisfaction of patients with dentures. To increase complete denture satisfaction, the importance of training programs aimed at enhancing dentist-patient communication and denture quality cannot be overemphasized.

  14. 21 CFR 872.3165 - Precision attachment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... conjunction with removable partial dentures. Various forms of the device are intended to connect a lower partial denture with another lower partial denture, to connect an upper partial denture with another upper partial denture, to connect either an upper or lower partial denture to a tooth or a crown, or to connect...

  15. Denture plaque--past and recent concerns.

    PubMed

    Nikawa, H; Hamada, T; Yamamoto, T

    1998-05-01

    This paper critically reviews the history of denture plaque and identifies some concerns with the presence of Candida in the mouth. This review covers literature sources related to Candida albicans and its relationship to denture plaque. The articles selected for this review are from referred journals and describe C. albicans and its relationship to oral, gastrointestinal and pleuropulmonary infections. The relationship to caries, root caries and periodontal disease is also covered. Denture plaque containing Candida could cause not only oral candidiasis, like oral thrush or denture-induced stomatitis, but also caries, root caries and periodontitis of abutment teeth. However, there is only limited experimental evidence or information available on the cariogenicity of Candida. The continuous swallowing or aspiration of micro-organisms from denture plaque exposes patients, particularly the immunocompromised host or medicated elderly, to the risks of unexpected infections. The term, 'denture plaque' has been used throughout the review. However, the term 'plaque on denture' should be used because the microbial flora and its pathogenicity of denture plaque resembles those of plaque formed on the tooth surface, so called dental plaque. In addition, the term 'denture related stomatitis' would be preferable to 'denture induced stomatitis', since the inflammation of (palatal) mucosa is not induced by the denture, but by wearing the denture or by plaque on the denture.

  16. Clinical evaluation of three denture cushion adhesives by complete denture wearers.

    PubMed

    Koronis, Spyros; Pizatos, Evangelos; Polyzois, Gregory; Lagouvardos, Panagiotis

    2012-06-01

    The aim of this study was the clinical evaluation of three denture cushion adhesives and whether the results were correlated to Kapur Index for denture-supporting tissues. Various types of denture adhesives are used among denture patients. However, information on the clinical behaviour of denture cushions is limited. Thirty edentulous patients had their denture-supporting tissues scored by Kapur Index and their old dentures replaced. They received three brands of denture cushion adhesives (Fittydent(®) , Protefix(®) and Seabond(®)) and were instructed to use them in a sequence according to the group they were randomly assigned to. Each brand of adhesive was used for 48 h on the lower denture according to the manufacturer's suggestions. After each brand was used, participants spent 24 h without applying any sort of adhesive. Finally, a questionnaire evaluating and comparing the performance of each brand was filled out. Denture adhesives generally improved patient satisfaction and masticatory ability, especially in participants with poor Kapur Index and those who reported a poor retention of their old dentures. Fittydent(®) was the most preferred adhesive, showing the best retention and the longest duration of its effect, but also reported as difficult to remove from the denture-bearing area. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  17. Accelerating effects of cellulase in the removal of denture adhesives from acrylic denture bases.

    PubMed

    Harada-Hada, Kae; Mimura, Sumiyo; Hong, Guang; Hashida, Tatsumi; Abekura, Hitoshi; Murata, Hiroshi; Nishimura, Masahiro; Nikawa, Hiroki

    2017-04-01

    Studies of effective methods for the easy removal of denture adhesives from a denture base are not well represented in the literature. We previously assessed the removability of denture adhesives by immersing within denture cleaners, showing that some cleaners have a weak effect, insufficiently effective in daily use. In this study, we prepared a cellulase, as a potential component for denture adhesive removers, and we examined whether the addition of cellulase to denture cleaners is effective in the removal of cream denture adhesives. We prepared the cellulase Meicelase as one component for the liquefaction of denture adhesives. We used two denture cleaners and two cream adhesives. After the immersion of plates in sample solutions, we evaluated the area of the sample plate still covered with adhesives. Biofilm removal assay was also performed using denture cleaners containing cellulase. The addition of cellulase accelerated the removal of cream adhesives in immersion experiments to a rate faster than that of water and denture cleaners. However, it did not influence the removability of Candida albicans biofilms from acrylic resin specimens. Cellulase hastened the liquefaction of cream adhesives. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  18. Influence of denture surface roughness and host factors on dental calculi formation on dentures: a cross-sectional study.

    PubMed

    Matsumura, Keisuke; Sato, Yuji; Kitagawa, Noboru; Shichita, Toshiharu; Kawata, Daisuke; Ishikawa, Mariko

    2018-05-04

    Dental calculi formation on dentures can worsen the oral cavity environment by complicating oral hygiene. However, few studies have investigated the effect of how patients use and manage their dentures, denture surface roughness, and host factors such as oral cavity dryness and saliva properties on denture cleanliness and denture dental calculi formation. Accordingly, we conducted the present survey to evaluate these factors to clarify the strength of the influence of each factor. We enrolled 53 patients who had used dentures for at least 3 months and used a dental prosthesis that covered at least the six front teeth including the left and right mandibular canines. After staining the dentures, we divided the participants into a group that was positive for dental calculi (DCP group) and a group that was negative for dental calculi (DCN group). After removing all the stains, we evaluated the surface roughness of the dentures. A questionnaire was used to survey how the participants used and managed their dentures. Oral cavity dryness was evaluated, and resting saliva samples were collected to assess saliva properties. Correlations between the presence or absence of dental calculi and denture use and management were evaluated using a chi-square test. Correlations with denture surface roughness, oral cavity dryness, and saliva properties were evaluated using the Mann-Whitney U test. Correlations between the presence or absence of dental calculi and all factors were analyzed using multivariate analysis (quantification II). Surface roughness was significantly greater in the DCP group (p < 0.01), and the DCP group members wore their dentures during sleep significantly more often and used a denture cleaner when storing their dentures significantly less often (both p < 0.01). No significant differences were observed for oral cavity dryness or saliva properties. The multivariate analysis showed significant correlations of dental calculi formation with denture surface roughness and items related to denture use and management, but not for oral cavity dryness or saliva properties. Our findings indicate that dental calculi formation is influenced by how dentures are used and managed and by denture surface roughness, but not by oral cavity dryness and saliva properties.

  19. A Simplified Technique to Measure Plaque on the Intaglio Surfaces of Complete Dentures.

    PubMed

    Almas, Khalid; Salameh, Ziad; Kutkut, Ahmad; Al Doubali, Ahmad

    2015-04-01

    The main aim of this study was to develop a simplified quantitative denture plaque index that could help dentists to motivate denture patients to maintain optimal oral hygiene. The secondary aim was to assess specific areas of dentures more prone to accumulate plaque and subjects' oral hygiene habits related to their dentures. One hundred subjects who wore maxillary and/or mandibular complete dentures for at least one year were included in the study as a powered sample. Fifteen females and 85 males, age range 45-75 years, were recruited. The study was carried out at King Saud University (KSU), College of Dentistry. A plaque disclosing solution was used to assess the plaque covered areas of denture. A quantitative percentage (10 x 10%) score index was developed by assessing plaque scores from digital images of intaglio surfaces of the dentures. The weighted kappa method was used to assess inter-examiner agreement in the main study. The new denture plaque index was identified as ASKD-DPI (Almas, Salameh, Kutkut, and Doubali-Denture Plaque Index). It ranged from 0 - 100%, and reflected the percentage of the intaglio surfaces of maxillary and mandibular complete dentures that contained plaque. It also classified quantitative percentages: 30 subjects ranged from 0 - 30% (low DPI), 50 subjects ranged from 31 - 70% (moderate DPI), and 20 subjects ranged from 71 - 100% (high DPI) denture plaque score. A simplified denture plaque index (ASKD-DPI) technique was developed and tested in this study. ASKD-DPI may be used for evaluating denture plaque scores, monitoring denture hygiene, and measuring compliance of patients regarding plaque control for complete dentures.

  20. Quality of Life with Removable Dentures

    PubMed Central

    Hadzipasic-Nazdrajic, Amra

    2011-01-01

    Goal: To measure change in a quality of life after treatment with removable dentures and to describe differences in quality of life in patients with new and worn out dentures. Materials and methods: Measuring instrument was OHIP-49, translated from English into one of the languages in Bosnia-Herzegovina. Sample consisted of patients who wanted to make/replace mobile dentures or came to repair a broken dentures. Comprehensibility of the OHIP-BH49 was tested on a sub-sample of patients. Three measurements were made: before and after the insertion of dentu res and when patients came to repair their mobile dentures. Results: Sample consisted of 67 patients: 32 patients who sought prosthetic treatment, and 35 who came to repair their broken dentures. We received 89.7% correctly filled questionnaires. Minor changes were made in four (4) questions. Statistical analysis performed with the T-test revealed the significant differences, before and after the treatment with mobile dentures (t=39.5, p<0.001). There was a significant difference in OHIP scores in patients with a new dentures, compared to the patients who had worn out dentures (t=44.30, p<0.001). Substantial differences, between OHIP scores, regarding the time of wearing dentures or patients’ age were not observed. Discussion: Patients who wore dentures longer than 5 years, showed better quality of life, because they became accustomed to the dentures. Conclusions: Self-reported life quality improved considerably after insertion of a new dentures. Patients with a new dentures showed significantly better quality of life than patients with worn out dentures. One part of OHIP validation in Bosnia-Herzegovina has been done. PMID:23678299

  1. Effect of location of glass fiber-reinforced composite reinforcement on the flexural properties of a maxillary complete denture in vitro.

    PubMed

    Takahashi, Yutaka; Yoshida, Kaneyoshi; Shimizu, Hiroshi

    2011-07-01

    Objective. To evaluate the effect of the location of glass fiber-reinforced composite (FRC) reinforcement on the flexural load at the proportional limit (FL-PL) and the flexural deflection of a maxillary acrylic resin complete denture. Material and methods. Maxillary acrylic resin complete dentures strengthened with and without FRC reinforcement were tested. The polymerized FRC was embedded in the denture base resin in the doughy state and placed (1) under the ridge lap region, (2) in the anterior region, (3) in the middle region or (4) in the anterior and posterior regions. The FL-PL and flexural deflection value at the 100-N loading point of the reinforced maxillary denture specimens were tested. Results. All of the reinforced dentures had a higher FL-PL than the denture without reinforcement but the FL-PL values of all the dentures were not significantly different from each other. The efficiency of the FRC reinforcement compared to the unreinforced denture was 1.54-1.75 times greater. All of the reinforced dentures showed significantly lower deflection compared to the unreinforced denture, but the flexural deflections of all the dentures were not significantly different from each other. Conclusions. The location of the FRC reinforcement did not affect the fracture resistance of the maxillary acrylic resin complete denture. All of the reinforced dentures had higher FL-PL and lower flexural deflection than the denture without reinforcement.

  2. Improvdent: Improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures

    PubMed Central

    2012-01-01

    Background According to the UK Adult Dental Health Survey (2009) 15% of adults aged 65–74, 30% aged 75–84 and 47% aged >85 years are edentulous and require complete dentures. Patients’ quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. Methods/Design IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone). Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period). Patients will then wear each set of dentures for a period of 8 weeks (in random order) during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period). Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference) and confirmation period (adjusted denture preference). A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. Funding: IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300). Discussion This trial aims to provide evidence on the costs and quality of dentures cast from two different commonly used impression materials; the intention is to significantly impact on the quality of denture production within NHS dentistry. Trial Registration ISRCTN Register: ISRCTN01528038 UKCRN Portfolio ID: 8305 PMID:22937901

  3. On the clinical deformation of maxillary complete dentures. Influence of denture-base design and shape of denture-bearing tissue.

    PubMed

    el Ghazali, S; Glantz, P O; Strandman, E; Randow, K

    1989-04-01

    This paper aimed to study the influence of denture base design and the shape of the denture-supporting area on the functional deformation of maxillary complete dentures. Six strain-gauged duplicate maxillary dentures were made for the study of two test subjects with different shapes of the palatal vault. Each subject was supplied with two polymethyl methacrylate dentures, one with a 1-mm-thick palatal base and the other 2 mm thick. A third denture was constructed with a cobalt-chromium base. The functional loading tests included maximum biting and the chewing of the food test samples. An analysis based on chewing time and total number of chewing cycles per test piece was also made. The results showed that surface straining is highly complex at the anterior part of the maxillary dentures constructed from polymethyl methacrylate and that increasing the denture thickness per se might not be accompanied by a reduction of strain. The results also suggest that high thrust to the supporting tissue is produced with high palatal vault dentures made in polymethyl methacrylate. The study proposes that cobalt-chromium bases may be used in maxillary dentures to reduce functional deformation and thrust to the supporting tissues at the anterior part of the maxilla.

  4. [The paper summarizes data on laboratory and clinical assessment of Corega dent Laboratory and clinical analysis of Corega denture adhesive cream mechanical properties].

    PubMed

    Kalivradzhiyan, E S; Podoprigora, A V; Kaverina, E Yu; Bobeshko, M N

    The paper summarizes data on laboratory and clinical assessment of Corega denture adhesive cream adhesive properties: adhesion strength and time of adhesive material fixing. Clinical assessment was based on Ulitovsky-Leontyev denture fixation index evaluated in 18 edentulous patients with full removable dentures 1 and 12 months after denture manufacturing. After one year of evaluation denture fixation in patients using Corega denture adhesive cream was 8-15% better (depending on alveolar bed anatomy) than in controls proving that Corega improves full denture adaptation to physiological atrophy of alveolar bone.

  5. Effect of denture cleansers on color stability, surface roughness, and hardness of different denture base resins

    PubMed Central

    Porwal, Anand; Khandelwal, Meenakshi; Punia, Vikas; Sharma, Vivek

    2017-01-01

    Aim: The purpose of this study was to evaluate the effect of different denture cleansers on the color stability, surface hardness, and roughness of different denture base resins. Materials and Methods: Three denture base resin materials (conventional heat cure resin, high impact resin, and polyamide denture base resin) were immersed for 180 days in commercially available two denture cleansers (sodium perborate and sodium hypochlorite). Color, surface roughness, and hardness were measured for each sample before and after immersion procedure. Statistical Analysis: One-way analysis of variance and Tukey's post hoc honestly significant difference test were used to evaluate color, surface roughness, and hardness data before and after immersion in denture cleanser (α =0.05). Results: All denture base resins tested exhibited a change in color, surface roughness, and hardness to some degree in both denture cleansers. Polyamides resin immersed in sodium perborate showed a maximum change in color after immersion for 180 days. Conventional heat cure resin immersed in sodium hypochlorite showed a maximum change in surface roughness and conventional heat cure immersed in sodium perborate showed a maximum change in hardness. Conclusion: Color changes of all denture base resins were within the clinically accepted range for color difference. Surface roughness change of conventional heat cure resin was not within the clinically accepted range of surface roughness. The choice of denture cleanser for different denture base resins should be based on the chemistry of resin and cleanser, denture cleanser concentration, and duration of immersion. PMID:28216847

  6. Occlusal force discrimination by denture patients.

    PubMed

    Pacer, R J; Bowman, D C

    1975-06-01

    A study was conducted on subjects with conventional dentures and with overlay dentures to compare their abilities to discriminate between occlusal forces. Perpendicular forces were applied to the dynamic center of the occlusal table of the mandibular denture. Each subject's ability to distinguish differences in values of force was observed and recorded. All subjects with dentures showed sensory threshold values close to those reported for natural teeth. A graphic plotting showed that the responses of subjects with overlay-type dentures were more closely correlated with the psychophysical law as expressed by Stevens as a power function. Since this phenomenon holds true for natural teeth, the overlay denture more closely resembles natural teeth in this type of sensory function than does the conventional denture. In addition to recognized advantages, such as preservation of the ridge and improved retention and stability, the overlay denture provides more typical sensory function than is provided by the conventional denture. This advantage should further motivate dentists and patients to consider the retention and utilization of at least two suitable teeth in an overlay-type denture service.

  7. On denture marking.

    PubMed

    Borrman, H I; DiZinno, J A; Wasén, J; René, N

    1999-06-01

    During the last decades in Sweden dentures have been permanently marked with a stainless steel metal band incorporated into the acrylic and containing the patient's birth date, a special number, and "S" for Sweden. The last recommendation issued by the National Board of Health and Welfare states that "the patients shall always be offered denture marking and be informed about the benefit thereof. Denture marking is not permitted if the patient refuses it". Requirements for denture markers have been that they should be biologically inert (when incorporated into the denture), not be expensive, be easy to inscribe, be possible to retrieve after an accident, and survive elevated temperatures for a reasonable time under normal circumstances. Although the frequency of edentulousness has decreased in recent years due to the improvement in oral health there remains a need to address the issue of marking of complete dentures, because there is a large variation in the oral status of populations in different countries. Given that only one marked denture can reveal the identity of a deceased person when all other methods fail to do so, makes it worthwhile. Furthermore, denture marking is important in long-term care facilities. We have investigated the issue of denture marking in Europe and in the United States. The results from the European survey show that denture marking is, to our knowledge regulated by law only in Sweden and Iceland. In the US denture marking is so far mandatory in 21 states while New York State requires dentures to be marked if the patient requests it and several other states impose the obligation to mark dentures on long-term care facilities. Since there is no international consensus regarding the issue of denture marking it is important to address it. A survey from the Nordic countries has shown that if denture marking was in general use, the contribution to the establishment of identity by forensic odontology in cases of fire would increase by about 10%. This means that about 25 more individuals could have been identified if their dentures were marked. Increased international collaboration is needed to solve the issue of denture marking for clinical and forensic purposes.

  8. Masticatory performance of complete denture wearers after using two adhesives: a crossover randomized clinical trial.

    PubMed

    de Oliveira Junior, Norberto Martins; Rodriguez, Larissa Santana; Mendoza Marin, Danny Omar; Paleari, André Gustavo; Pero, Ana Carolina; Compagnoni, Marco Antonio

    2014-11-01

    Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (P<.001). No significant difference was found between the 2 denture adhesives evaluated. The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. [Improving the speech with a prosthetic construction].

    PubMed

    Stalpers, M J; Engelen, M; van der Stappen, J A A M; Weijs, W L J; Takes, R P; van Heumen, C C M

    2016-03-01

    A 12-year-old boy had problems with his speech due to a defect in the soft palate. This defect was caused by the surgical removal of a synovial sarcoma. Testing with a nasometer revealed hypernasality above normal values. Given the size and severity of the defect in the soft palate, the possibility of improving the speech with speech therapy was limited. At a centre for special dentistry an attempt was made with a prosthetic construction to improve the performance of the palate and, in that way, the speech. This construction consisted of a denture with an obturator attached to it. With it, an effective closure of the palate could be achieved. New measurements with acoustic nasometry showed scores within the normal values. The nasality in the speech largely disappeared. The obturator is an effective and relatively easy solution for palatal insufficiency resulting from surgical resection. Intrusive reconstructive surgery can be avoided in this way.

  10. Patients' experiences with partial dentures: a qualitative study.

    PubMed

    Smith, Patricia A; Entwistle, Vikki A; Nuttall, Nigel

    2005-12-01

    The aim of the study was to gain insight into people's experiences of being given and using partial dentures. In-depth semi-structured interviews were carried out with 23 people of varied age, social background and denture wearing experience in Tayside, Scotland. Participants were encouraged to discuss how they came to have partial dentures, their day-to-day denture use and their interactions with dentists. The interview data were systematically coded using key theme headings, and summary charts were constructed to facilitate analysis. The initial decision that a partial denture was needed was generally difficult to accept. People perceived the main benefits of partial dentures to be improved appearance and confidence, but experienced a variety of difficulties with their dentures and often coped with these by only wearing them on social occasions. Participants had not always told their dentists about the difficulties they experienced. Barriers to seeking help with denture problems included financial constraints, previous experience of rushed appointments or poor communication from dentists and a perceived lack of entitlement to help when partial dentures were issued free. Partial dentures can be difficult to cope with. People experience a range of difficulties in wearing them, not all of which have been discussed with dentists. Informative and supportive communication when partial dentures are first needed, and subsequently, can improve the quality of patients' experiences and may help promote effective use and appropriate help-seeking by partial denture wearers.

  11. Study protocol for a multi-center, randomized controlled trial to develop Japanese denture adhesive guidelines for patients with complete dentures: the Denture Adhesive Guideline trial: study protocol for a randomized controlled trial.

    PubMed

    Kimoto, Suguru; Kawai, Yasuhiko; Gunji, Atsuko; Kondo, Hisatomo; Nomura, Taro; Murakami, Tomohiko; Tsuboi, Akito; Hong, Guang; Minakuchi, Shunsuke; Sato, Yusuke; Ohwada, Gaku; Suzuki, Tetsuya; Kimoto, Katsuhiko; Hoshi, Noriyuki; Saita, Makiko; Yoneyama, Yoshikazu; Sato, Yohei; Morokuma, Masakazu; Okazaki, Joji; Maeda, Takeshi; Nakai, Kenichiro; Ichikawa, Tetsuo; Nagao, Kan; Fujimoto, Keiko; Murata, Hiroshi; Kurogi, Tadafumi; Yoshida, Kazuhiro; Nishimura, Masahiro; Nishi, Yasuhiro; Murakami, Mamoru; Hosoi, Toshio; Hamada, Taizo

    2016-10-18

    Denture adhesives, characterized as medical products in 1935 by the American Dental Association, have been considered useful adjuncts for improving denture retention and stability. However, many dentists in Japan are hesitant to acknowledge denture adhesives in daily practice because of the stereotype that dentures should be inherently stable, without the aid of adhesives. The aim of this study is to verify the efficacy of denture adhesives to establish guidelines for Japanese users. The null hypothesis is that the application of denture adhesives, including the cream and powder types, or a control (isotonic sodium chloride solution) would not produce different outcomes nor would they differentially improve the set outcomes between baseline and day 4 post-application. This ten-center, randomized controlled trial with parallel groups is ongoing. Three hundred edentulous patients with complete dentures will be allocated to three groups (cream-type adhesive, powder-type adhesive, and control groups). The participants will wear their dentures with the denture adhesive for 4 days, including during eight meals (three breakfasts, two lunches, and three dinners). The baseline measurements and final measurements for the denture adhesives will be performed on the first day and after breakfast on the fourth day. The primary outcome is a general satisfaction rating for the denture. The secondary outcomes are denture satisfaction ratings for various denture functions, occlusal bite force, resistance to dislodgement, masticatory performance, perceived chewing ability, and oral health-related quality of life. Between-subjects comparisons among the three groups and within-subjects comparisons of the pre- and post-intervention measurements will be performed. Furthermore, a multiple regression analysis will be performed. The main analyses will be based on the intention-to-treat principle. A sample size of 100 subjects per group, including an assumed dropout rate of 10 %, will be required to achieve 80 % power with a 5 % alpha level. This randomized clinical trial will provide information about denture adhesives to complete denture wearers, prosthodontic educators, and dentists in Japan. We believe this new evidence on denture adhesive use from Japan will aid dentists in their daily practice even in other countries. ClinicalTrials.gov NCT01712802 . Registered on 17 October 2012.

  12. Candida albicans biofilm heterogeneity does not influence denture stomatitis but strongly influences denture cleansing capacity.

    PubMed

    O'Donnell, Lindsay E; Alalwan, Hasanain K A; Kean, Ryan; Calvert, Gareth; Nile, Christopher J; Lappin, David F; Robertson, Douglas; Williams, Craig; Ramage, Gordon; Sherry, Leighann

    2017-01-01

    Approximately 20  % of the UK population wear some form of denture prosthesis, resulting in denture stomatitis in half of these individuals. Candida albicans is primarily attributed as the causative agent, due to its biofilm -forming ability. Recently, there has been increasing evidence of C. albicans biofilm heterogeneity and the negative impact it can have clinically; however, this phenomenon has yet to be studied in relation to denture isolates. The aims of this study were to evaluate C. albicans biofilm formation of clinical denture isolates in a denture environment and to assess antimicrobial activity of common denture cleansers against these tenacious communities. C. albicans isolated from dentures of healthy and diseased individuals was quantified using real-time PCR and biofilm biomass assessed using crystal violet. Biofilm development on the denture substratum poly(methyl methacrylate), Molloplast B and Ufi-gel was determined. Biofilm formation was assessed using metabolic and biomass stains, following treatment with denture hygiene products. Although C. albicans was detected in greater quantities in diseased individuals, it was not associated with increased biofilm biomass. Denture substrata were shown to influence biofilm biomass, with poly(methyl methacrylate) providing the most suitable environment for C. albicans to reside. Of all denture hygiene products tested, Milton had the most effective antimicrobial activity, reducing biofilm biomass and viability the greatest. Overall, our results highlight the complex nature of denture- related disease, and disease development cannot always be attributed to a sole cause. It is the distinct combination of various factors that ultimately determines the pathogenic outcome.

  13. Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

    PubMed

    Alfadda, Sara A; Al Amri, Mohammad D; Al-Ohali, Amal; Al-Hakami, Arwa; Al-Madhi, Noura

    To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P < .05. The clinicians' overall mean rating of the clinical quality of the dentures was 91.5% (standard deviation 6.27%). The stability of the mandibular overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r = 0.389 and r = 0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the maxillary conventional denture. IID had no effect on the clinical quality of either denture and did not influence patient satisfaction.

  14. Does the nature of the definitive impression material influence the outcome of (mandibular) complete dentures?

    PubMed

    McCord, J Fraser; McNally, Lisa M; Smith, Philip W; Grey, Nicholas J A

    2005-09-01

    The effects of impression materials on the outcome of complete dentures are poorly understood. This double-blind cross-over randomized controlled trial investigated eleven adult edentulous patients. Each received a maxillary denture and three mandibular dentures (which differed only in the three materials used to record the definitive impressions). The three mandibular dentures were given in a random order. Patients' opinions of each denture were recorded using a Linear Analogue Scale. There was a statistically-significant difference between the outcome of the dentures constructed when zinc-oxide eugenol was used, this material being least favoured (p < 0.001). It would therefore appear that care should be exercised when selecting impression materials when constructing mandibular complete dentures.

  15. Management of bruxism-induced complications in removable partial denture wearers using specially designed dentures: a clinical report.

    PubMed

    Baba, Kazuyoshi; Aridome, Kumiko; Pallegama, Ranjith Wasantha

    2008-01-01

    In patients with a limited number of remaining teeth, bruxism force can be destructive for both the remaining teeth and periodontal structures. This paper reports the successful management of four such patients with severe sleep bruxism, using conventional removable partial dentures and specially designed, splint-like removable partial dentures called a night denture. The night denture was fabricated in two different designs, which depended upon the pattern of the remaining tooth contacts. The patients were followed up for 2-6 years using a night denture in either of the two designs. Within the limitations of these four reports of clinical cases, the night denture appeared to be effective in managing the problems related to sleep bruxism.

  16. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    PubMed

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  17. Comparison of retention between maxillary milled and conventional denture bases: A clinical study.

    PubMed

    AlHelal, Abdulaziz; AlRumaih, Hamad S; Kattadiyil, Mathew T; Baba, Nadim Z; Goodacre, Charles J

    2017-02-01

    Clinical studies comparing the retention values of milled denture bases with those of conventionally processed denture bases are lacking. The purpose of this clinical study was to compare the retention values of conventional heat-polymerized denture bases with those of digitally milled maxillary denture bases. Twenty individuals with completely edentulous maxillary arches participated in this study. Definitive polyvinyl siloxane impressions were scanned (iSeries; Dental Wings), and the standard tessellation language files were sent to Global Dental Science for the fabrication of a computer-aided design and computer-aided manufacturing (CAD-CAM) milled denture base (group MB) (AvaDent). The impression was then poured to obtain a definitive cast that was used to fabricate a heat-polymerized acrylic resin denture base resin (group HB). A custom-designed testing device was used to measure denture retention (N). Each denture base was subjected to a vertical pulling force by using an advanced digital force gauge 3 times at 10-minute intervals. The average retention of the 2 fabrication methods was compared using repeated ANOVA (α=.05). Significantly increased retention was observed for the milled denture bases compared with that of the conventional heat-polymerized denture bases (P<.001). The retention offered by milled complete denture bases from prepolymerized poly(methyl methacrylate) resin was significantly higher than that offered by conventional heat- polymerized denture bases. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Bonding of acrylic denture teeth to MMA/PMMA and light-curing denture base materials: the role of conditioning liquids.

    PubMed

    Palitsch, Anne; Hannig, Matthias; Ferger, Paul; Balkenhol, Markus

    2012-03-01

    The connection between resin denture teeth and the denture base is essential for the integrity of partial and full dentures. The aim of the present study was to analyse the bond strength of acrylic denture teeth to two light curing denture base materials compared to the gold-standard (MMA/PMMA) using different conditioning liquids. The ridge laps of 220 identical denture teeth were ground and pre-treated using different conditioning liquids (MMA, an experimental conditioning liquid as well as the two commercially available liquids Palabond and Versyo.bond). The denture base materials (PalaXpress, Versyo.com, Eclipse) were applied using a split mould to obtain tensile bond strength specimens of identical shape. Ten specimens per test group were either stored in water for 24h or thermocycled (5000×, 5-55°C) prior to tensile bond strength testing (cross-head speed 10mm/min). Data was subjected to parametric statistics (α=0.05). The three-way ANOVA revealed a significant influence of the material, pre-treatment as well as the storage. PalaXpress showed the highest bond strength (24.3MPa) of all materials tested after TC, whereas the use of MMA led to the most constant results. Lower values were recorded for Versyo.com (17.5MPa) and Eclipse (10.4MPa) bonded with Versyo.bond. The results indicate that MMA/PMMA based denture base resins provide reliable and durable bond strength to acrylic denture teeth. Using light-curing denture base materials requires the application of appropriate conditioning liquids to obtain acceptable bond strength. The use of MMA affects bond strength to light-curing denture base materials. The pre-treatment of denture teeth is critical regarding their bond-strength to denture base materials and in turn for the integrity of removable full and partial dentures. Light-curing denture base resins are more sensitive to the correct tooth pre-treatment compared to conventional MMA/PMMA materials, requiring specific conditioning liquids. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Implant Rehabilitation Planning Protocol for the Edentulous Patient According to Denture Space, Lip Support, and Smile Line.

    PubMed

    Lago, Laura; Rilo, Benito; Fernández-Formoso, Noelia; DaSilva, Luis

    2017-08-01

    Rehabilitation with implants is a challenge. Having previous evaluation criteria is key to establishing the best treatment for the patient. In addition to clinical and radiological aspects, the prosthetic parameters must be taken into account in the initial workup, since they allow discrimination between fixed and removable rehabilitation. We present a study protocol that analyzes three basic prosthetic aspects. First, denture space defines the need to replace teeth, tissue, or both. Second, lip support focuses on whether or not to include a flange. Third, the smile line warns of potential risks in esthetic rehabilitation. Combining these parameters allows us to make a decision as to the most suitable type of prosthesis. The proposed protocol is useful for assessing the prosthetic parameters that influence decision making as to the best-suited type of restoration. From this point of view, we think it is appropriate for the initial approach to the patient. In any case, other considerations of study may amend the proposal. © 2016 by the American College of Prosthodontists.

  20. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM-bonded, injection, and fluid resin. Techniques involving compression during processing showed increased positive occlusal tooth movement compared with techniques not involving compression. CAD-CAM monolithic dentures produced the best combination of accuracy and reproducibility of the tested techniques. The results from this study demonstrate that varying amounts of tooth movement can be expected depending on the processing technique. However, the clinical significance of these differences is unknown. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.

    PubMed

    Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-03-08

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.

  2. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

    PubMed Central

    Al-mejrad, Lamya A.; Albarrag, Ahmed M.

    2017-01-01

    PURPOSE The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures. PMID:29142649

  3. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    PubMed

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P <.05). The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  4. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins

    PubMed Central

    Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022

  5. Biomechanical factors related to occlusal load transfer in removable complete dentures.

    PubMed

    Żmudzki, Jarosław; Chladek, Grzegorz; Kasperski, Jacek

    2015-08-01

    Owing to economic conditions, removable dentures remain popular despite the discomfort and reduced chewing efficiency experienced by most denture wearers. However, there is little evidence to confirm that the level of mucosal load exceeds the pressure pain threshold. This discrepancy stimulated us to review the current state of knowledge on the biomechanics of mastication with complete removable dentures. The loading beneath dentures was analyzed in the context of denture foundation characteristics, salivary lubrication, occlusal forces, and the biomechanics of mastication. The analysis revealed that the interpretation of data collected in vivo is hindered due to the simultaneous overlapping effects of many variables. In turn, problems with determining the pressure beneath a denture and analyzing frictional processes constitute principal limitations of in vitro model studies. Predefined conditions of finite element method simulations should include the effects of oblique mastication forces, simultaneous detachment and sliding of the denture on its foundation, and the stabilizing role of balancing contacts. This review establishes that previous investigations may have failed because of their unsubstantiated assumption that, in a well-working balanced occlusion, force is only exerted perpendicular to the occlusal plane, allowing the denture to sit firmly on its foundation. Recent improvements in the simulation of realistic biomechanical denture behavior raise the possibility of assessing the effects of denture design on the pressures and slides beneath the denture.

  6. Assessment of Hygiene Habits in Acrylic Denture Wearers: a Cross-sectional Study

    PubMed Central

    Aoun, Georges; Gerges, Elie

    2017-01-01

    Objectives: To assess the denture hygiene habits in a population of Lebanese denture wearers. Materials and Methods: One hundred and thirty-two (132) patients [71 women (53.8%) and 61 men (46.2%)] wearing their acrylic dentures for more than two years were included in this study. The hygiene methods related to their dentures were evaluated and the data obtained were analyzed statistically using the IBM® SPSS® statistics 20.0 (USA) statistical package. Results: Regardless of the cleaning technique, the big majority of our participants [123 out of 132 (93.1%)] cleaned their dentures daily. The two mostly used denture cleaning techniques were rinsing with tap water (34.1%) and brushing with toothpaste (31.8%). Nearly half of our patients (45.5%) soaked their dentures during the night; most of them with cleansing tablets dissolved in water (28.8%). Conclusions: Within the limitations of our study, it was concluded that in a sample of Lebanese population surveyed about denture hygiene habits, the daily frequency of denture cleaning is satisfactory, but the techniques and products used were self-estimated and, consequently, not sufficient. PMID:29109670

  7. An investigation into denture loss in hospitals in Kent, Surrey and Sussex.

    PubMed

    Mann, J; Doshi, M

    2017-08-25

    Background The loss of dentures for inpatients can have a detrimental effect on their well-being. Self-respect and dignity become compromised along with their ability to eat meals and communicate clearly, and long-term recovery.Aim This investigation aimed to identify the reported number of dentures lost in hospitals and the financial reimbursements given by trusts to replace them.Method Information on reported denture loss and reimbursement was collected in 12 trusts throughout Kent, Surrey and Sussex.Results Eleven out of 12 trusts returned data about how many dentures were lost in their hospitals, between them 695 dentures were reported lost over five years (2011-16). Seven trusts reported financial reimbursements for dentures losses; results showed £357,672 was reimbursed over six years (2010-16), the highest amount reimbursed for a single denture was £2,200.Conclusion The results indicate that denture loss is a problem in hospitals that contributes to the financial burden for the NHS. Consideration needs to be given by hospitals to find ways to reduce the number of dentures lost every year.

  8. A new concept in denture design for patients with few remaining teeth: case reports.

    PubMed

    Ling, B C

    1995-12-01

    This article presents an alternative to the conventional swing-lock de sign of removable partial denture construction. It incorporates the principles of sectional dentures as well as the swing-lock concept and overcomes some of the limitations of conventional swing-lock dentures. I-bar struts and stainless steel keepers form part of the first section of the denture. The second part of the denture consists of the denture base with the artificial teeth and magnetic retention units. This system has been used successfully in a number of patients whose situations were suitable for the conventional swing-lock design.

  9. Technical Quality of Complete Dentures: Influence on Masticatory Efficiency and Quality of Life.

    PubMed

    Tôrres, Ana Clara Soares Paiva; Maciel, Amanda de Queiroz; de Farias, Danielle Bezerra; de Medeiros, Annie Karoline Bezerra; Vieira, Flávia Patrícia Tavares Veras; Carreiro, Adriana da Fonte Porto

    2017-11-09

    To evaluate the effect of the technical quality of conventional complete dentures (CD) on masticatory efficiency and quality of life (QoL) of denture wearers during a 1-year follow-up. A prospective clinical trial with 32 edentulous patients (mean age of 60.2 years) wearing mandibular and maxillary dentures was conducted. All patients were evaluated wearing their preexisting dentures and after 3, 6, and 12 months postinsertion of new dentures. A reproducible method for objective evaluation of the technical quality of CDs was employed. Masticatory efficiency was evaluated by the colorimetric method using beads as artificial testing food. The oral health impact on patient QoL was measured using the OHIP-EDENT (Oral Health Impact Profile in Edentulous Adults) questionnaire. The nonparametric Wilcoxon test was applied to reveal any differences in technical quality between the preexisting and new dentures. The Friedman test was used to detect differences in masticatory efficiency and oral health impact on QoL. Spearman's correlation was applied to reveal correlation between the variables. Comparing preexisting and new dentures, significant improvement was found in technical quality between the dentures (p < 0.001). There was no statistically significant difference in masticatory efficiency. A significant decrease was found in the total OHIP-EDENT scores after denture replacement. A positive correlation was found between technical quality and OHIP in the new denture wearers (p = 0.011). According to the results of this study, denture quality significantly improved patients' oral health-related QoL; however, insertion of new dentures did not influence masticatory efficiency. © 2017 by the American College of Prosthodontists.

  10. Vascularized interpositional periosteal connective tissue flap: A modern approach to augment soft tissue

    PubMed Central

    Agarwal, Chitra; Deora, Savita; Abraham, Dennis; Gaba, Rohini; Kumar, Baron Tarun; Kudva, Praveen

    2015-01-01

    Context: Nowadays esthetics plays an important role in dentistry along with function of the prosthesis. Various soft tissue augmentation procedures are available to correct the ridge defects in the anterior region. The newer technique, vascularized interpositional periosteal connective tissue (VIP-CT) flap has been introduced, which has the potential to augment predictable amount of tissue and has many benefits when compared to other techniques. Aim: The study was designed to determine the efficacy of the VIP-CT flap in augmenting the ridge defect. Materials and Methods: Ten patients with Class III (Seibert's) ridge defects were treated with VIP-CT flap technique before fabricating fixed partial denture. Height and width of the ridge defects were measured before and after the procedure. Subsequent follow-up was done every 3 months for 1-year. Statistical Analysis Used: Paired t-test was performed to detect the significance of the procedure. Results: The surgical site healed uneventfully. The predictable amount of soft tissue augmentation had been achieved with the procedure. The increase in height and width of the ridge was statistically highly significant. Conclusion: The VIP-CT flap technique was effective in augmenting the soft tissue in esthetic area that remained stable over a long period. PMID:25810597

  11. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... with the oral tissues. After the denture base is constructed, the connected preformed teeth are...: Evaluation and Testing,’ ” and (2) “OTC Denture Reliners, Repair Kits, and Partially Fabricated Denture Kits...

  12. A comparative analysis of salivary factors and maxillary denture retention in different arch forms: An in vivo study.

    PubMed

    Shekhar, Abhishek; Das, Samiran; Bhattacharyya, Jayanta; Goel, Preeti; Majumdar, Sayan; Ghosh, Soumitra

    2018-01-01

    This study aims to find the effect of change in different salivary factors before and after complete denture insertion and to measure the maxillary denture retention in different arch forms. Thirty completely edentulous individuals (10 each of square, tapered, and ovoid arch form of maxilla) belonging to the age group of 40-70 years were selected. Salivary factors (flow, density, pH, viscosity, and total protein) were evaluated before and after denture insertion. Retention of maxillary denture was measured in all the different arch forms. Student's independent sample's t -test was applied. The correlation was analyzed by Pearson's correlation analysis. While mean flow rate and pH of saliva increased, mean viscosity, total protein, and density of saliva decreased after maxillary complete denture insertion. A positive correlation was found between retention and total maxillary basal surface area. Retention value was found to be greatest in square type and least in tapered type. Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.

  13. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    PubMed

    Polyzois, Gregory L; de Baat, Cees

    2012-06-01

    To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. The survey took place in Greece and the Netherlands with a sample of 284 and 165 consecutive complete denture wearers, respectively, by using a 9-item prepared questionnaire. Statistical analysis relied on chi-square test at α = 0.05. In this survey, 26 and 20% of Greek and Dutch patients, respectively, had tried denture adhesive, but only 27% of them in Greece as well as in the Netherlands currently used it; 49% of the Greek and 45% of the Dutch participants rated the overall performance of adhesives as good. Between the two populations, no differences were identified in a majority of the research variables, except where 27% of Greeks answered that they did not know the existence of denture adhesives compared to none of the Dutch patients and when 90% of the Dutch contrary to 70% of Greeks reported that they did not need denture adhesives as they could manage their dentures well. The usage of and attitudes towards denture adhesives between the Greek and Dutch sample were similar with only two exceptions concerning the knowledge of existence and the need of using denture adhesives. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  14. Complete denture services: clinical technique, lab costs, manpower, and reimbursement. One-year review.

    PubMed

    Ewoldsen, Nels

    2011-01-01

    Complete denture services at comprehensive care public health clinics are not common in part because of clinician concerns regarding outcomes. Educational debt forgiveness has attracted recent dental graduates to public health dentistry; however, not all recent graduates receive denture education experiences necessary to attain proficiency. While fundamental patient assessment and denture construction are taught, psychological assessment and communication with denture patients requires experience. A thorough understanding of occlusion, phonetics, esthetics and laboratory steps is also necessary. Expecting recent dental graduates to become proficient providing complete dentures at minimal reimbursement levels, with no mentorship or on-site laboratory support, is unrealistic. Public health dental clinics operate at full capacity performing emergency, preventive and restorative procedures. Complete dentures come with a laboratory fee approximately one-half the total reimbursement, meaning a remake drops clinic revenue to zero while doubling expenses. It is understandable that full schedules, marginal reimbursement, unpredictability and the risk of an occasional failure block clinician interest in providing denture services. This one-year report of services describes a three-appointment complete denture technique offering improved patient and laboratory communication, reduced chair time and controlled cost, resulting in high-quality complete dentures.

  15. Oral health-related quality of life in patients with non-metal clasp dentures: a randomised cross-over trial.

    PubMed

    Fueki, K; Yoshida-Kohno, E; Wakabayashi, N

    2017-05-01

    We investigated the efficacy of non-metal clasp dentures (NMCDs) with regard to the oral health-related quality of life (OHRQoL) and compare the findings with those for conventional metal clasp-retained dentures (MCDs). This single-centre, randomised controlled, two-phase, open label, cross-over trial included 28 partially dentate individuals. The patients were randomised to receive MCDs followed by NMCDs, or the opposite sequence (n = 14 in each group); each denture was worn for 3 months. OHRQoL was evaluated using the Oral Health Impact Profile-Japanese version (OHIP-J) at entry (T-entry; before treatment with the first denture) and at 3 months after treatment with each denture (T3). An examiner evaluated denture stability, oral appearance and surface roughness before denture delivery (T0) and at T3 and denture hygiene at T3. A total of 24 patients completed the trial. There were no complications related to the dentures, abutment teeth or denture-bearing mucosa during the follow-up periods for both dentures. The mean OHIP summary score was lower for NMCDs than for MCDs, and the difference (9 points) was greater than the minimal important difference (6 points), indicating the difference was clinically relevant. The effect size was medium (0·70). Statistical analyses with linear mixed models found a significant effect of the denture type on the OHIP summary score and scores for the Oro-facial appearance, Oro-facial pain and Psychological impact domains (NMCD < MCD; P < 0·05). The results of our study suggest that NMCDs allow for better OHRQoL compared with MCDs. © 2017 John Wiley & Sons Ltd.

  16. Denture labeling: A new approach

    PubMed Central

    Bansal, Pardeep K.; Sharma, Akshey; Bhanot, Rajesh

    2011-01-01

    The need for denture labeling is important for forensic and social reasons in case patients need to be identified individually. The importance of denture marking has long been acknowledged by the dental profession. Over the years, various denture marking systems have been reported in the literature, but none till date fulfills all the prescribed ADA specifications. A simple, easy, inexpensive procedure for marking accurate identification marks on dentures with a lead foil is described here. The label caring the patient information is incorporated in the acrylic resin during the denture processing. PMID:21957379

  17. The effect of denture adhesives on Candida albicans growth in vitro.

    PubMed

    Sampaio-Maia, Benedita; Figueiral, Maria Helena; Sousa-Rodrigues, Patricia; Fernandes, Maria Helena; Scully, Crispian

    2012-06-01

    Denture-wearing favours the growth of Candida. In view of the fact that many denture wearers regularly use adhesives to enhance denture retention, stability and function, the aim of this work was to study the effect of denture adhesives on Candida albicans growth in vitro. The denture adhesives tested were Corega(®) cream, Kukident(®) cream, Novafix(®) cream, Polident(®) cream, Protefix(®) cream, Steradent(®) cream, Aderyn(®) powder, Corega(®) ultra powder, Protefix(®) powder and Corega(®) strip. C. albicans growth curves were obtained in the presence or absence of a 1% solution of the denture adhesive diluted in Sabouraud broth. Macro- and microscopic morphological changes in C. albicans were analysed, as was microbial contamination of the denture adhesive. Most of the denture adhesives studied induced morphological changes in C. albicans cells and colonies, but only two had any significant inhibitory effect on yeast growth. Kukident(®) cream markedly inhibited C. albicans growth in a concentration-dependent way, reducing the growth rate by 95%, whereas Corega(®) cream also inhibited C. albicans growth but in a non-concentration-dependent way, reducing the growth rate by 37%. In addition, denture adhesives available as powders had detectable microbial contamination. Some commercially available denture adhesives showed microbial contamination and some had significant inhibitory effect on C. albicans growth. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  18. Knowledge of removable partial denture wearers on denture hygiene.

    PubMed

    Milward, P; Katechia, D; Morgan, M Z

    2013-11-01

    Regular good denture hygiene by individuals with removable partial dentures (RPDs) is an important component of oral health and in the prevention of further dental problems. These individuals should be provided with advice on the importance of denture care and be aware of this information. To establish deficiencies in patient knowledge surrounding denture hygiene by RPD wearers. The study was undertaken as an audit. Data was collected from April 2012 to October 2012 via a questionnaire completed by 196 RPD wearers attending as patients at the University Dental Hospital Wales and the dental units at St David's Hospital and Cynon Valley Hospital. The audit criterion was patients with RPDs should have knowledge of denture hygiene, with the standard set at 100%. While 91.8% of participants stated they were provided with instructions on denture hygiene when provided with their current prosthesis, 60.2% were shown to have less than an appropriate level of denture cleanliness, with 9.2% reporting that they slept wearing their prosthesis. The audit criterion and standard set were not achieved. A lack of knowledge surrounding denture hygiene was demonstrated among participants. As a part of the audit process the health education of RPD wearers' hygiene needs to be improved and awareness levels of the whole dental team needs to be raised. All partial dentures should receive information and regular reinforcement of key dental hygiene messages.

  19. Different types of antagonists modify the outcome of complete denture renewal.

    PubMed

    Berteretche, Marie Violaine; Frot, Amélie; Woda, Alain; Pereira, Bruno; Hennequin, Martine

    2015-01-01

    The effect of renewing removable dentures on masticatory function was evaluated according to the occlusion offered by different types of mandibular arches. Twenty-eight patients with complete maxillary dentures were subdivided into three groups in terms of mandibular dentition type: dentate, partial denture, and complete denture. The participants were observed before and 8 weeks after maxillary denture renewal. The mandibular denture was also renewed in the partial and complete denture groups. The participants masticated carrots, peanuts, and three model foods of different hardnesses. The particle size distribution of the boluses obtained from natural foods was characterized by the median particle size (d50) in relation to the masticatory normative indicator (MNI). Chewing time (CT), number of chewing cycles (CC), and chewing frequency (CF) were video recorded. A self-assessment questionnaire for oral health-related quality of life (Geriatric Oral Health Assessment Index [GOHAI]) was used. Statistical analyses were carried out with a mixed model. Renewal of the dentures decreased d50 (P < .001). The number of participants with d50 values above the MNI cutoff decreased from 12 to 2 after renewal. Renewal induced an increase in mean CF while chewing model foods (P < .001). With all foods, renewal tended to affect CT, CC, and CF differently among the three groups (statistically significant renewal Å~ group interactions). The GOHAI score increased significantly for all groups. Denture renewal improves masticatory function. The complete denture group benefited least from renewal; the dentate group benefited most. This study confirmed the usefulness of denture renewal for improving functions and oral health- related quality of life.

  20. Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases.

    PubMed

    Nirale, Rutuja Madhukarrao; Thombre, Ram; Kubasad, Girish

    2012-02-01

    To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n = 20). Data were analyzed using student paired 't' and unpaired 't' test. Microwave disinfection produces significant shrinkage in both denture bases without relining (t = 17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability.

  1. Evaluation of cleansing methods for previously worn prostheses.

    PubMed

    Glass, R Thomas; Conrad, Robert S; Bullard, James W; Goodson, Leigh B; Mehta, Naresh; Lech, Stanley J; Loewy, Zvi G

    2011-04-01

    Although there are many product claims that address the issue of denture sanitization, controlled scientific studies on previously worn dentures have not been performed. The purpose of this study was to evaluate procedures directed at sanitizing previously worn contaminated dentures from two regions of the United States. This study examined 51 previously worn dentures from two regions. An established method of denture retrieval, sectioning, and culturing was used, including isolation of anaerobes. Evaluation of microbial contamination posttreatment was used to determine the effects of soaking dentures in Polident (US and European formulations) for varying periods of times/temperatures, microwaving dentures with varying temperatures, sonicating dentures, and immersing the dentures while using a vacuum. A combination of analysis of variance (ANOVA) and general linear model (GLM) of the SPSS was used to analyze the data with P < .05 being considered statistically significant when using a two-tailed test. While all Polident treatments were found to significantly reduce microorganism loads in dentures, extended soaking (8 hours) and 65 degrees C (5 minutes) were the most effective. Microwaving was slightly more effective than either sonication or vacuum. Regardless the treatment, dentures underwent sanitization rather than sterilization. Denture-borne microorganisms can be significantly reduced by using a Polident solution for 8 hours at room temperature or for 5 minutes at 65 degrees C. Microwaving, sonication, and use of a vacuum were less effective. ClLINICAL IMPLICATIONS The importance of daily use of Polident solution for 8 hours or for 5 minutes at 65 degrees C to sanitize worn prostheses must be stressed.

  2. [Development of visible-light cured FRP denture].

    PubMed

    Yu, P Y

    1990-06-01

    Acrylic denture may be fractured easily because it has a relatively poor resistance to stresses of impact, and the thick acrylic denture base also uncomforted to denture wearers. In this study, for improvement of the mechanical properties, the FRP is applied to the denture base, and try to make a thin denture base. Using the visible light-curing system, the laboratory fabrication time is saved dramatically. To develop the visible light-cured FRP denture base, with various combination of matrix resins and reinforcements, the physical properties of FRP plates were investigated first. From the results of the bending test, hardness test, and manipulation considering, the sateen weave's glasscloth was choose as the reinforcement of the prepreg. The matrix resin of Bis-GMA/UDMA/3G at 48/48/4 wt% was determined. The 3 plies glasscloth included FRP plate is 0.8 mm thickness has the maximum bending strength about 50 kgf/mm2, which is about 5 times larger than that of acrylic resin. Succeeding the study of above, the FRP denture base was fabricated by using the 0.8 mm thickness 3 plies included prepreg. This repreg is manufactured in sheet form beforehand, which is ease to manipulate at laboratory. By using the visible light curing system, it is only taken 10 min. to make a FRP denture base. The following procedures of fabricating a FRP denture is the same as metalplate denture. The visible-light cured FRP denture has some advantages such as accuracy of fit, ease of fabrication and manipulation, and only 0.8 mm thickness but has superior strength.

  3. [Guywire dentures].

    PubMed

    Riakhovskiĭ, A N

    2000-01-01

    Analyzes possible complications and shortcomings of traditional prosthetic treatments. Presents a new approach to prosthetic treatment and describes the general design of guy dentures. Describes in brief the biomechanics, methods of making guy dentures, and discusses their advantages in comparison with the traditional dentures.

  4. A clinical evaluation denture adhesives used by patients with xerostomia.

    PubMed

    Bogucki, Zdzislaw A; Napadlek, Piotr; Dabrowa, Tomasz

    2015-02-01

    The purpose of study was to analyze the participants' opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia.

  5. Candida albicans importance to denture wearers. A literature review.

    PubMed

    Gleiznys, Alvydas; Zdanavičienė, Eglė; Žilinskas, Juozas

    2015-01-01

    Opportunistic oral fungal infections have spred, especially in denture wearers. Denture stomatitis is a common inflammatory reaction, multifactorial etiology, which is usually associated with Candida species, particularly Candida albicans, due to its high virulence, ability to adhere and form biofilms on oral cavity tissues and denture surfaces. This article highlights the pathogenesis, clinical presentation, and management strategies of Candida-associated denture stomatitis commonly encountered in dental practice.

  6. The effect of various factors on the masticatory performance of removable denture wearer

    NASA Astrophysics Data System (ADS)

    Pratama, S.; Koesmaningati, H.; Kusdhany, L. S.

    2017-08-01

    An individual’s masticatory performance concerns his/her ability to break down food in order to facilitate digestion, and it therefore plays an important role in nutrition. Removable dentures are used to rehabilitate a loss of teeth, which could jeopardize masticatory performance. Further, there exist various other factors that can affect masticatory performance. The objective of this research is to analyze the relationship between various factors and masticatory performance. Thirty-four removable denture wearers (full dentures, single complete dentures, or partial dentures) participated in a cross-sectional study of masticatory performance using color-changeable chewing gum (Masticatory Performance Evaluating Gum Xylitol®). The volume of saliva was evaluated using measuring cups, while the residual ridge heights were measured using a modified mouth mirror no. 3 with metric measurements. The residual ridge height and removable-denture-wearing experience exhibited a significant relationship with masticatory performance. However, age, gender, saliva volume, denture type, and the number and location of the missing teeth did not have a statistically significant association with masticatory performance. The residual ridge height influences the masticatory performance of removable denture wearers, since the greater the ridge height, the better the performance. The experience of using dentures also has a statistically significant influence on masticatory performance.

  7. Elderly complete denture wearers: a social approach to tooth loss.

    PubMed

    Papadaki, Eftychia; Anastassiadou, Vassiliki

    2012-06-01

    To correlate emotional reactions to tooth loss with denture satisfaction attributes in elderly complete denture wearers. Total tooth loss is a serious life event, and poor oral health has an impact on daily life. Edentulism treated by rehabilitation with dentures can have a positive effect on patients' self-image and social behaviour. A group of 80 edentulous subjects undergoing routine prosthetic care in a Greek Department of Prosthetic Dentistry were interviewed using two structured questionnaires. The first questionnaire explored reactions to tooth loss, whereas the second measured their subjective experience of complete dentures. The responses to both questionnaires were compared using the statistical package SPSS v.17. The results showed significant correlation between aspects of tooth loss experience and complete denture satisfaction. Despite the fact that a substantial proportion of patients were satisfied with their complete dentures, some patients experienced increased social and psychological problems related to their edentulousness and the wearing of complete dentures. The aesthetic and functional aspects of complete dentures affected both patients' social behaviour and self-confidence. Total tooth loss was not only reflected in patient's social behaviour and self-image, but it had a complex and multifaceted impact on satisfaction from complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  8. Development of a Contemporary Animal Model of Candida albicans-Associated Denture Stomatitis Using a Novel Intraoral Denture System

    PubMed Central

    Johnson, Clorinda C.; Yu, Alika; Lee, Heeje; Fidel, Paul L.

    2012-01-01

    Denture stomatitis (DS) is a fungal infection characterized by inflammation of the oral mucosa in direct contact with the denture and affects up to 50% of denture wearers. Despite the prevalence, very little is known about the role of fungal or host factors that contribute to pathogenesis. Recently, we developed a novel intraoral denture system for rodent research. This denture system consists of custom-fitted fixed and removable parts to allow repeated sampling and longitudinal studies. The purpose of this study was to use this denture system to develop a clinically relevant animal model of DS. To establish DS, rats were inoculated with pelleted Candida albicans, which resulted in sustained colonization of the denture and palate for 8 weeks postinoculation. Biofilm formation on the denture was observed by week 4 and on the palate by week 6 postinoculation. Rats were monitored for clinical signs of disease by assigning a clinical score after macroscopic examination of the palate tissue according to Newton's method. By week 4 postinoculation, the majority of inoculated rats with dentures exhibited a clinical score of 1 (pinpoint erythema). By week 6 and week 8 postinoculation, increasing percentages of rats exhibited a clinical score of 2 (diffuse erythema/edema). Histological analysis of palate tissue demonstrated progressively increasing inflammatory cell recruitment throughout the time course of the infection. Palatal biofilm formation was commensurate with development of palatal erythema, which suggests a role for biofilm in the inflammatory response. PMID:22392931

  9. In Vitro Wear Resistance of Nano-Hybrid Composite Denture Teeth.

    PubMed

    Munshi, Nabeel; Rosenblum, Marc; Jiang, Shuying; Flinton, Robert

    2017-04-01

    To evaluate the wear resistance of nano-hybrid composite denture teeth as compared to two commonly used denture teeth: interpenetrating polymer network (IPN) and double crosslinking polymethylmethacrylate (PMMA) denture teeth. 18 styli and 18 disk specimens were prepared from the three denture tooth materials: nano-hybrid composite, IPN, and double crosslinking PMMA. The specimens were mounted in a two-body wear testing machine to simulate chewing in the complete denture. The amount of wear from the styli specimens were measured before and after using a digital micrometer, and the depth of the wear track from the disk specimens was measured using a noncontact 3D optical profilometer. The total wear from each denture tooth group was compared using one-way ANOVA with a 0.05 significance level. A Tukey post hoc test was used to determine differences between the three groups. The mean total wear in the nano-hybrid composite teeth group was 1.16 mm, SD = 0.5 mm, statistically significantly higher (p ≤ 0.0001) than the IPN (mean = 0.13 mm, SD = 0.05) and double crosslinking PMMA tooth groups (mean = 0.31 mm, SD = 0.19). There was no statistically significant difference between IPN denture teeth and double crosslinking PMMA denture teeth in the amount of wear. Nano-hybrid composite denture teeth exhibited statistically significantly more wear than the IPN and double crosslinking PMMA denture teeth. © 2015 by the American College of Prosthodontists.

  10. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  11. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  12. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  13. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  14. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  15. Complete denture biofilm after brushing with specific denture paste, neutral soap and artificial saliva.

    PubMed

    Paranhos, Helena de Freitas Oliveira; Salles, Antônio Eduardo Sparça; Macedo, Leandro Dorigan de; Silva-Lovato, Cláudia Helena da; Pagnano, Valéria Oliveira; Watanabe, Evandro

    2013-01-01

    This study compared the levels of biofilm in maxillary and mandibular complete dentures and evaluated the number of colony-forming units (cfu) of yeasts, after using auxiliary brushing agents and artificial saliva. Twenty-three denture wearers with hyposalivation and xerostomia were instructed to brush the dentures 3 times a day during 3 weeks with the following products: Corega Brite denture dentifrice, neutral liquid soap, Corega Brite combined with Oral Balance (artificial saliva) or tap water. For biofilm quantification, the internal surfaces of the dentures were disclosed, photographed and measured using a software. For microbiological analysis, the biofilm was scrapped off, and the harvested material was diluted, sown in CHROMagar™ Candida and incubated at 37°C for 48 h. Data were analyzed statistically by two-way ANOVA and Tukey's test (α=0.05). Mandibular dentures presented a mean biofilm percentage (µ=26.90 ± 21.10) significantly greater than the maxillary ones (µ=18.0 ± 15.0) (p<0.05). Brushing using Corega Brite combined with Oral Balance (µ=15.87 ± 18.47) was more effective (p<0.05) than using the denture dentifrice (µ=19.47 ± 17.24), neutral soap (µ=23.90 ± 18.63) or tap water (control; µ=32.50 ± 20.68). For the microbiological analysis, the chi-square test did not indicate significant difference between the hygiene products for either type of denture. The more frequently isolated species of yeasts were C. albicans, C. tropicalis and C. glabrata. In conclusion, mandibular dentures had more biofilm formation than maxillary ones. Denture brushing with Corega Brite dentifrice combined with the use of Oral Balance was the most effective method for reduction of biofilm levels, but the use of products did not show difference in yeast cfu counts.

  16. Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

    PubMed Central

    Thombre, Ram; Kubasad, Girish

    2012-01-01

    PURPOSE To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. MATERIALS AND METHODS A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n = 20). Data were analyzed using student paired 't' and unpaired 't' test. RESULTS Microwave disinfection produces significant shrinkage in both denture bases without relining (t = 17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). CONCLUSION Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability. PMID:22439097

  17. Denture hyperplasia with areas simulating oral inverted ductal papilloma.

    PubMed

    Vargas, Pablo Agustin; Perez, Danyel Elias da Cruz; Jorge, Jacks; Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Almeida, Oslei Paes de

    2005-07-01

    Denture hyperplasia is a reactive lesion of the oral mucosa, usually associated to an ill-fitting denture. This lesion is easily diagnosed and in some cases distinct microscopic variations such as osseous, oncocytic and squamous metaplasia may be found. These metaplastic alterations probably are associated with the lymphocytic infiltrate usually present in denture hyperplasia. We present a case of denture hyperplasia containing salivary gland tissue with ductal alterations mimicking an oral inverted ductal papilloma.

  18. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  19. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  20. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  1. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  2. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  3. Analysis of the effects of removable dentures on the psychological status, quality of life, and masticatory function of the elderly

    NASA Astrophysics Data System (ADS)

    Dyas, R.; Nathanael, M.; Indrasari, M.; Masulili, C.; Rahardjo, T. B.; Agustin, D.; Hogervorst, E.; Kusdhany, L.

    2017-08-01

    Older age is a major risk factor for diseases of the teeth and mouth and dementia. Diseases of the teeth and mouth can lead to tooth loss. The use of removable dentures can help the elderly to replace lost teeth; therefore, dentures are expected to improve the masticatory function, quality of life, and psychological status of the elderly. The aim of this study was to analyze the effects of removable denture usage on the improvement of the psychological status, quality of life, and masticatory function of elderly people. The data was obtained from 30 respondents. The patients answered questionnaires before they used the dentures, 2 weeks after they began using dentures, and 2 months after they started wearing dentures. Four different questionnaires were used: EuroQol Five Dimensions questionnaire (EQ-5D) and Geriatric Depression Scale (GDS), to measure psychological status; a mastication questionnaire to measure masticatory function; and a validated quality of life questionnaire. Based on the results of this study, it is clear that after 2 months of denture usage, removable dentures in the elderly can significantly improve their quality of life, masticatory function, and psychological status(p<0.05).

  4. A Clinical Evaluation Denture Adhesives Used by Patients With Xerostomia

    PubMed Central

    Bogucki, Zdzislaw A.; Napadlek, Piotr; Dabrowa, Tomasz

    2015-01-01

    Abstract The purpose of study was to analyze the participants’ opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia. PMID:25700320

  5. Effectiveness of a Chlorhexidine Digluconate 0.12% and Cetylpyridinium Chloride 0.05% Solution in eliminating Candida albicans Colonizing Dentures: A Randomized Clinical in vivo Study.

    PubMed

    Aoun, Georges; Cassia, Antoine; Berberi, Antoine

    2015-06-01

    Effective denture hygiene is important for patients suffering from denture stomatitis (DS). This study aimed to evaluate the efficacy of a solution containing 0.12% chlorhexidine (CHX) digluconate and 0.05% cetylpyridinium chloride (CPC) in eliminating Candida albicans colonizing dentures. Forty denture wearers (11 men, 29 women; age range 40 to 80 years) with clinical evidence of DS were randomly divided into two groups, one test and one control. The dentures of the test group were treated by immersion in a solution of 0.12% CHX and 0.05% CPC while those of the control group were immersed in distilled water. Swabs were collected from the fitting surfaces of the upper dentures prior and post cleaner use and examined mycologically. Reduction in the number of colony-forming units (CFU) of Candida albicans after immersion of the dentures in a solution of 0.12% CHX and 0.05% CPC was significantly greater than that of the control group. A solution of 0.12% CHX and 0.05% CPC tested as a product of disinfection of the acrylic dentures showed significant results after immersion of 8 night hours for 4 days.

  6. Design and fabrication of complete dentures using CAD/CAM technology

    PubMed Central

    Han, Weili; Li, Yanfeng; Zhang, Yue; lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    Abstract The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures. The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures. Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures. Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM. PMID:28072686

  7. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  8. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  9. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  10. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  11. 21 CFR 872.3580 - Preformed gold denture tooth.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a) Identification. A preformed gold denture tooth is a device composed of austenitic alloys or alloys containing 75...

  12. 21 CFR 872.3530 - Mechanical denture cleaner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mechanical denture cleaner. 872.3530 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3530 Mechanical denture cleaner. (a) Identification. A mechanical denture cleaner is a device, usually AC-powered, that consists of a container for...

  13. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  14. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  15. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  16. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  17. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  18. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  19. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  20. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  1. 21 CFR 872.3590 - Preformed plastic denture tooth.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Preformed plastic denture tooth. 872.3590 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3590 Preformed plastic denture tooth. (a) Identification. A preformed plastic denture tooth is a prefabricated device, composed of materials such as methyl...

  2. Use of metal conditioner on reinforcement wires to improve denture repair strengths.

    PubMed

    Shimizu, Hiroshi; Mori, Nobuaki; Takahashi, Yutaka

    2008-03-01

    The purpose of this study was to evaluate the transverse strength of denture base resin repaired with autopolymerizing resin and metal wire using a metal conditioner, along with the synergistic effect of a surface preparation for denture base resin. It was found that the use of Co-Cr-Ni wires air abraded with 50 microm alumina, followed by treatment with a metal conditioner and dichloromethane for denture base resin, was the most effective method for repairing fractured denture base resin.

  3. Effect of long-term water immersion or thermal shock on mechanical properties of high-impact acrylic denture base resins.

    PubMed

    Sasaki, Hirono; Hamanaka, Ippei; Takahashi, Yutaka; Kawaguchi, Tomohiro

    2016-01-01

    The purpose of this study was to investigate the effect of long-term water immersion or thermal shock on the mechanical properties of high-impact acrylic denture base resins. Two high-impact acrylic denture base resins were selected for the study. Specimens of each denture base material tested were fabricated according to the manufacturers' instructions (n=10). The flexural strength at the proportional limit, the elastic modulus and the impact strength of the specimens were evaluated. The flexural strength at the proportional limit of the high-impact acrylic denture base resins did not change after six months' water immersion or thermocycling 50,000 times. The elastic moduli of the high-impact acrylic denture base resins significantly increased after six months' water immersion or thermocycling 50,000 times. The impact strengths of the high-impact acrylic denture base resins significantly decreased after water immersion or thermocycling as described above.

  4. Sectional mandibular complete denture for a total maxillectomy patient with trismus: a clinical report.

    PubMed

    Celakil, Tamer; Demir, Azize; Keskin, Haluk

    2017-01-01

    This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  5. 21 CFR 872.3400 - Karaya and sodium borate with or without acacia denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... denture adhesive. 872.3400 Section 872.3400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... and sodium borate with or without acacia denture adhesive. (a) Identification. A karaya and sodium borate with or without acacia denture adhesive is a device composed of karaya and sodium borate with or...

  6. The use of natural teeth in overlay dentures.

    PubMed

    Frantz, W R

    1975-08-01

    A method has been described for the construction of tooth-supported dentures where the natural tooth was utilized and the acrylic resin for the denture base processed directly to the prepared cast. Based on the 112 dentures that were made, this technique is economical, provides support and stabilization, and has full patient acceptance.

  7. Denture-associated biofilm infection in three-dimensional oral mucosal tissue models.

    PubMed

    Morse, Daniel J; Wilson, Melanie J; Wei, Xiaoqing; Lewis, Michael A O; Bradshaw, David J; Murdoch, Craig; Williams, David W

    2018-03-01

    In vitro analyses of virulence, pathogenicity and associated host cell responses are important components in the study of biofilm infections. The Candida-related infection, denture-associated oral candidosis, affects up to 60 % of denture wearers and manifests as inflammation of palatal tissues contacting the denture-fitting surface. Commercially available three-dimensional tissue models can be used to study infection, but their use is limited for many academic research institutions, primarily because of the substantial purchase costs. The aim of this study was to develop and evaluate the use of in vitro tissue models to assess infections by biofilms on acrylic surfaces through tissue damage and Candida albicans virulence gene expression. In vitro models were compared against commercially available tissue equivalents (keratinocyte-only, SkinEthic; full-thickness, MatTek Corporation). An in vitro keratinocyte-only tissue was produced using a cancer-derived cell line, TR146, and a full-thickness model incorporating primary fibroblasts and immortalised normal oral keratinocytes was also generated. The in vitro full-thickness tissues incorporated keratinocytes and fibroblasts, and have potential for future further development and analysis. Following polymicrobial infection with biofilms on acrylic surfaces, both in-house developed models were shown to provide equivalent results to the SkinEthic and MatTek models in terms of tissue damage: a significant (P<0.05) increase in LDH activity for mixed species biofilms compared to uninfected control, and no significant difference (P>0.05) in the expression of most C. albicans virulence genes when comparing tissue models of the same type. Our results confirm the feasibility and suitability of using these alternative in vitro tissue models for such analyses.

  8. Fracture strength of artificially aged 3-unit adhesive fixed partial dentures made of fiber-reinforced composites and ceramics: an in vitro study.

    PubMed

    Kolbeck, Carola; Rosentritt, Martin; Handel, Gerhard

    2006-10-01

    The aim of this in vitro study was to examine the fracture strength of metal-free 3-unit adhesive fixed partial dentures (AFPDs) bonded to mandibular incisors. Extracted human incisors were positioned in pairs in polymethyl methacrylate resin simulating a clinical anterior situation. Their lingual sides were prepared for adhesive retainers with surfaces and finishing lines in enamel. Eight 3-unit AFPDs were made on master casts per material system: Connect/belleGlass (Girrbach), StickNet (StickTech)/Sinfony (3M Espe), and Empress 2 (Ivoclar Vivadent). The dentures were bonded adhesively using the dual-curing system ED Primer/ Panavia F (Kuraray Europe) and aged by thermocycling (6,000 x 5 degrees C/55 degrees C H2O; 2 minutes each cycle) and mechanical loading (1.2 x 10(6) x 20 N with 1.66 Hz) in an artificial oral environment representing a wearing period of 5 years. The fracture strength was determined in a universal testing machine (UTM 1446, Zwick) at a speed of 1 mm/min, applying the load buccoincisally on the pontics. The different forms of failure were described optically. Medians (25th/75th percentiles) of the fracture results were calculated. Statistical analysis was performed using Mann-Whitney U and Kruskal-Wallis tests (P < or = .05). Five StickNet/Sinfony AFPDs and 7 Empress 2 restorations failed in the artificial oral environment. The remaining Empress 2 dentures showed the highest medians of fracture forces (339 [200/506] N) compared to Connect/belleGlass (257 [242/310] N) and StickNet/Sinfony (256 [204/347] N). Statistical comparisons showed no significant differences. Only Connect/belleGlass and Empress 2 showed sufficient resistance against mastication

  9. Effectiveness of Hexetidine 0.1% Compared to Chlorhexidine Digluconate 0.12% in Eliminating Candida Albicans Colonizing Dentures: A Randomized Clinical In Vivo Study.

    PubMed

    Aoun, Georges; Saadeh, Maria; Berberi, Antoine

    2015-08-01

    Denture hygiene is an important factor in the prevention and treatment of denture stomatitis (DS). This study aimed to evaluate the efficacy of two different mouthwashes (chlorhexidine digluconate 0.12% and hexetidine 0.1%) in eliminating Candida albicans on dentures. A total of 60 denture wearers (20 men, 40 women; age range 40-80 years) with clinical evidence of DS were randomly divided into 2 test groups and 1 control group. The dentures of each test group were treated by immersion in one of the two mouthwashes while those of the control group were immersed in distilled water. Swab samples from the palatal surfaces of the upper dentures were collected before and after of cleaner use and examined mycologically. Reduction in the number of colony-forming units of Candida albicans after immersion of the dentures with chlorhexidine digluconate 0.12% was significantly greater than that of the group using hexetidine 0.1% and those of the control group. Hexetidine 0.1% solution tested for the first time as a product of disinfection of the acrylic dentures showed average results after immersion of 8 night hours for 4 days and was less effective than chlorhexidine digluconate 0.12%.

  10. Comparative evaluation of the effect of denture cleansers on the surface topography of denture base materials: An in-vitro study.

    PubMed

    Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N S

    2015-08-01

    The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. The values obtained were analyzed statistically using one-way ANOVA and paired t-test. All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased.

  11. Comparative evaluation of the effect of denture cleansers on the surface topography of denture base materials: An in-vitro study

    PubMed Central

    Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N. S.

    2015-01-01

    Aims: The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Materials and Methods: Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. Statistical Analysis Used: The values obtained were analyzed statistically using one-way ANOVA and paired t-test. Results: All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Conclusion: Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased. PMID:26538915

  12. [Longitudinal survey and analysis among Chengdu residents on cognition and acceptance of implant dentures].

    PubMed

    Zuo, Yanping; Wang, Yongyue; Wang, Luming; Du, Bing

    2014-08-01

    This study aims to survey the cognition and acceptance of implant dentures among Chengdu residents in 2005 and 2013 and to comparatively analyze the differences and influencing factors. A questionnaire was designed for this study. Its main content included basic demographics of respondents (gender, age, cultural level, and income level), cognition level of implant dentures (concept and main characteristics of implant dentures), main concern of respondents regarding implant dentures and medical institutions, and acceptance level of the price of implant dentures, among others. The sampling survey was carried out among Chengdu residents in 2005 and 2013 using the designed questionnaire. The results were then statistically analyzed. Up to 908 valid questionnaires in 2005 and 905 valid questionnaires in 2013 were obtained. The level of cognition of implant dentures was higher in 2013 than in 2005, and the correlation between cognition and cultural level and that between cognition and income level were both positive. However, the correlation between cognition and age was negative. The success rate for implant dentures and medical treatment technology of medical institutions were the factors that the respondents were mainly concerned with. The main methods for disseminating information on implant dentures were the internet, television, newspapers, magazines, and introduction by friends. With the development of the society's economy and the improvement of culture and income level of Chengdu residents, the cognition and acceptance level of implant dentures have gradualy increased. Meanwhile, health education and medical technology still need to be strengthened.

  13. Correlation of masticatory muscle activity with masticatory ability in complete denture patients with canine guidance and balanced occlusion

    NASA Astrophysics Data System (ADS)

    Maxwell, D.; Odang, R. W.; Koesmaningati, H.

    2017-08-01

    Balanced occlusion is commonly used in complete denture occlusion scheme; however, canine guidance offers a simpler process and reduces alveolar ridge resorption. Correlative research of these two occlusion schemes is required. This study was done to analyze the correlation between masticatory muscle activity and masticatory ability of the subjects with canine guidance and balanced occlusion complete dentures. Ten denture wearers participated in this cross-over clinical trial, and five subjects were randomly selected to wear balanced occlusion followed by canine guidance complete dentures and vice versa. Electromyogram (EMG) activities of superficial masseter and anterior temporal muscles were measured and masticatory ability questionnaires were collected 30 days after the subjects wore each occlusal scheme. There were significant differences between the EMG activities of masticatory muscles in subjects who were given canine guidance and balanced occlusion complete dentures (p < 0.05). Subjects rated their masticatory ability as being significantly better when using canine guidance dentures (p = 0.046). There was a significant and strong correlation (p = 0.045; r = 0.642) between the EMG activity of anterior temporal muscles and masticatory ability when the subjects wore balanced occlusion dentures and between the EMG activity of superficial masseter muscles and masticatory ability (p = 0.043; r = 0.648) when wearing canine guidance dentures. Masticatory ability is better when using canine guidance dentures. There is a significant and strong correlation between masticatory muscle activity and masticatory ability.

  14. Efficacy of denture adhesives in maxillary dentures using gnathodynamometry: a comparative study.

    PubMed

    Polyzois, Gregory; Lagouvardos, Panagiotis; Frangou, Maria; Stefaniotis, Theodoros

    2011-07-01

    The purpose of this study was to investigate the effect of four commercially available denture adhesives on the incisal and premolar dislodgement forces of maxillary complete dentures by using an electronic and disposable gnathodynamometer and compare the measured incisal forces for differences. This study was conducted with 12 complete maxillary denture wearers. Four commercially available denture adhesives Super Corega(®), Corega Ultra(®), Super Corega Powder(®) and Fittydent Cationic(®) were investigated. Testing protocol and sequence included baseline measurements without adhesives (control) for previous and new dentures and then replications of measurements with the four adhesives. Maximum dislodgement forces were recorded in two sites between central incisors and the left 2nd premolars by using an electronic and disposable gnathodynamometer. To estimate the effect of the different adhesives on the dislodgement forces, data were analyzed by a 2- and 3-way ANOVA, while for estimating the agreement of the two devices a Bland-Altman and Mountain plots were used. ANOVAs indicated significant differences between adhesives (p < 0.05), denture types (p < 0.05) and biting sites (p < 0.05) with both devices. Bland-Altman plot and Mountain plots indicated a poor agreement of the two devices. It was concluded that denture adhesives increase the denture dislodgement forces, but with differences among them. The two devices do not highly agree with each other, but each one alone is useful in estimating dislodgement forces in clinical practice and research.

  15. Improving mechanical properties of maxillary complete dentures through a bioinspired engineering design.

    PubMed

    White, James A P; Bond, Ian P; Jagger, Daryll C

    2011-01-01

    This study investigated how ribbed design features, including palatal rugae, may be used to significantly improve the structural performance of a maxillary denture under load. A computer-aided design model of a generic maxillary denture, incorporating various rib features, was created and imported into a finite element analysis program. The denture and ribbed features were assigned the material properties of standard denture acrylic resin, and load was applied in two different ways: the first simulating a three-point flexural bend of the posterior section and the second simulating loading of the entire palatal region. To investigate the combined use of ribbing and reinforcement, the same simulations were repeated with the ribbed features having a Young modulus two orders of magnitude greater than denture acrylic resin. For a prescribed load, total displacements of tracking nodes were compared to those of a control denture (without ribbing) to assess relative denture rigidity. When subjected to flexural loading, an increase in rib depth was seen to result in a reduction of both the transverse displacement of the last molar and vertical displacement at the centerline. However, ribbed features assigned the material properties of denture acrylic resin require a depth that may impose on speech and bolus propulsion before significant improvements are observed. The use of ribbed features, when made from a significantly stiffer material (eg, fiber-reinforced polymer) and designed to mimic palatal rugae, offer an acceptable method of providing significant improvements in rigidity to a maxillary denture under flexural load.

  16. Failure strengths of denture teeth fabricated on injection molded or compression molded denture base resins.

    PubMed

    Robison, Nathan E; Tantbirojn, Daranee; Versluis, Antheunis; Cagna, David R

    2016-08-01

    Denture tooth fracture or debonding remains a common problem in removable prosthodontics. The purpose of this in vitro study was to explore factors determining failure strengths for combinations of different denture tooth designs (shape, materials) and injection or compression molded denture base resins. Three central incisor denture tooth designs were tested: nanohybrid composite (NHC; Ivoclar Phonares II), interpenetrating network (IPN; Dentsply Portrait), and microfiller reinforced polyacrylic (MRP; VITA Physiodens). Denture teeth of each type were processed on an injection molded resin (IvoBase HI; Ivoclar Vivadent AG) or a compression molded resin (Lucitone 199; Dentsply Intl) (n=11 or 12). The denture teeth were loaded at 45 degrees on the incisal edge. The failure load was recorded and analyzed with 2-way ANOVA (α=.05), and the fracture mode was categorized from observed fracture surfaces as cohesive, adhesive, or mixed failure. The following failure loads (mean ±SD) were recorded: NHC/injection molded 280 ±52 N; IPN/injection molded 331 ±41 N; MRP/injection molded 247 ±23 N; NHC/compression molded 204 ±31 N; IPN/compression molded 184 ±17 N; MRP/compression molded 201 ±16 N. Injection molded resin yielded significantly higher failure strength for all denture teeth (P<.001), among which IPN had the highest strength. Failure was predominantly cohesive in the teeth, with the exception of mixed mode for the IPN/compression group. When good bonding was achieved, the strength of the structure (denture tooth/base resin combination) was determined by the strength of the denture teeth, which may be affected by the processing technique. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Space requirement of a prefabricated bar on two interforaminal implants: a prospective clinical study.

    PubMed

    Albrecht, Dominic; Ramierez, Ami; Kremer, Urs; Katsoulis, Joannis; Mericske-Stern, Regina; Enkling, Norbert

    2015-02-01

    This clinical study measured the dimensional changes of existing lower complete dentures due to the integration of a prefabricated implant bar. Additionally, the impact of this dimensional change on patient satisfaction and oral function was analyzed. Twenty edentulous patients (10 men/10 women; aged 65.9 ± 11.8 years) received two interforaminal implants. Subsequent to surgery, a chair side adapted, prefabricated bar (SFI Bar(®), C+M, Biel, Switzerland) was inserted, and the matrix was polymerized into the existing lower denture. The change of the denture's lingual dimension was recorded by means of a bicolored, silicone denture duplicate that was sectioned in the oro-vestibular direction in the regions of the symphysis (S) and the implants (I-left, I-right). On the sections, the dimensional increase was measured using a light microscope. Six months after bar insertion, patients answered a standardized questionnaire. All dentures exhibited increased lingual volume, more extensively at S than at I (P = 0.001). At S, the median diagonal size of the denture was doubled (+4.33 mm), and at I, the median increase was 50% (I-left/-right = +2.66/+2.62 mm). The original denture size influenced the volume increase (P = 0.024): smaller dentures led to a larger increase. The amount of denture increase did not have negative impact on either self-perceived oral function or patient satisfaction. Approximately, 95% of the patients were satisfied with the treatment results. The lingual size of a lower denture was enlarged by the integration of a prefabricated bar without any negative side effects. Thus, this attachment system is suitable to convert an existing full denture into an implant-supported overdenture. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. A Clinical Study to Examine the Effect of Complete Denture on Head Posture/Craniovertical Angle.

    PubMed

    Khare, Amit; Nandeeshwar, D B; Sangur, Rajashekar; Makkar, Sumit; Khare, Pooja; Chitumalla, Rajkiran; Prasad, Renuka

    2016-04-01

    Edentulous patients show some significant changes in ridge relationship caused by resorption of alveolar ridge. The changes are characterized by an upward rotation of mandible, increase in mandibular prognathism that ultimately results in change of natural head posture. This clinical study was planned to know the effect of complete denture on head posture in different age groups of Indian completely edentulous population, after placement of complete denture at various time intervals. The sample consisted of completely edentulous patients without previous experience of the dentures. They were divided into 2 age groups: Group A (45-60) and Group B (61-75). During placement of complete denture craniovertical angle was measured with the help of custom made ruler protector device. Readings were taken before denture placement, immediately after denture placement, 30 minutes, 24 hours and 30 days after dentures placement. The results of this study indicated that in most of the patients (90%) despite their age, change in head posture (extension) occurred immediately after the denture placement. Thereafter reading remains same for measurement at 30 minutes and 24 hours of denture placement. However after 30 days, observation revealed that all the patients showed reduced craniovertical angle (flexion). Even though the values of craniovertical angle remain higher than its baseline in both groups, significant changes were noticed only in Group A. Findings revealed that head posture was significantly altered by the placement of dentures in completely edentulous patients. Within the time interval of 30 minutes and 24 hours extension of head posture remained constant with slight variation. Although after 30 days, changes remained significant for group 'A', but no significant changes were observed in the subjects of group 'B'.

  19. Provision of a swing lock denture for a patient with Gorlin Goltz syndrome.

    PubMed

    Razaq, I; Durey, K; Nattress, B

    2012-09-01

    Swinglock dentures are used relatively infrequently but in cases of compromised anatomy or where the pattern of tooth loss is unfavourable, they provide a useful removable partial denture design option. The aim of this article is to provide a clear summary of the clinical and technical considerations necessary when providing a Swinglock denture.

  20. A System Approach to Navy Medical Education and Training. Appendix 44. Competency Curriculum for Dental Assistant.

    DTIC Science & Technology

    1974-08-31

    Prosthodontic Appliances - Partial Dentures .... ....... ....... .... 59 2. Removable Prosthodontic Appliances - Full Dentures ..... ........... . 60 3...PROCEDURES I This unit includes the following Modules: Number Title Page 1 Removable Prosthodontic Appliances - Partial Dentures 59. ......... ...... 2...Removable Prostbodontic Appliances - Full Dentures ..... ...... a .. .. .. . 60 3 Fixed Prosthodontic Appliances - Fixed Bridge. . 61 4 Mouthquard

  1. Expectations and satisfaction of denture patients in a university clinic.

    PubMed

    Davis, E L; Albino, J E; Tedesco, L A; Portenoy, B S; Ortman, L F

    1986-01-01

    These results indicate that patients' expectations of dentures before treatment were unrealistically high and that informational videotapes did not significantly affect these expectations. Satisfaction with current dentures was surprisingly high before treatment and increased significantly from pretreatment to postreatment for both groups in the study. While it is likely that this increase in satisfaction reflects a change from poor to excellent denture status, this finding may also be attributed to cognitive dissonance theory; that is, high satisfaction may represent the means by which patients justify the expenses of their denture treatment. Although the videotape presentations did not alter the expectations of patients and their satisfaction with dentures, the tapes represent a potential source of accurate, standardized information for both patient and student dentist.

  2. Restoring Anterior Aesthetics by a Rotational Path Cast Partial Denture: An Overlooked Technique

    PubMed Central

    Bhat, Bala Saraswati; Arora, Himanshu

    2016-01-01

    Cast Partial Dentures (CPD) has long been known to restore missing teeth in patients with minimal invasion on hard and soft tissues. Although satisfactory otherwise, the main concern in CPD is the anterior display of metal. Also the technique sensitive lab procedures, together with the esthetic concern have built an iceberg around the frequent utilization of this treatment modality. With the advent of various techniques to get rid of the metallic display, it was predicted to have more CPD’s done in the dental arena. But the conceptual technicalities of the procedure took away the limelight from this treatment modality and focused on the fixed prosthodontics. Although feasible in a large number of patients, fixed prosthesis still has areas of restriction. It is here, when we apply our knowledge and skill of esthetic CPD. Esthetic CPD eliminates the metal display by utilizing desirable undercuts. The engaging action of the framework into these undercuts paves way for a rotational motion to seat the remaining prosthesis. Hence dual path of insertion helps eliminating the anterior clasp. In this case report dual path of insertion is discussed for replacing anterior teeth in an old male patient who had mild esthetic concerns. Following the conservative approach of CPD (over FPD) esthetic and restorative treatment was planned with patient’s consent. PMID:27437375

  3. Inhibitory effects of Lactobacillus rhamnosus and Lactobacillus casei on Candida biofilm of denture surface.

    PubMed

    Song, Young-Gyun; Lee, Sung-Hoon

    2017-04-01

    Candida albicans biofilm is associated with denture-related stomatitis and oral candidiasis of elderly. Probiotics are beneficial bacteria and have antibacterial activity against pathogenic bacteria. The purpose of this study was to investigate the antifungal activity of various probiotics against C. albicans and the inhibitory effects of probiotics on Candida biofilm on the denture surface. The spent culture media of various probiotics were investigated the antifungal efficacy against C. albicans. Candida biofilm was formed on a denture base resin and was then treated with Lactobacillus rhamnosus and Lactobacillus casei. Also, the biofilms of L. rhamnosus and L. casei were formed and were sequentially treated with C. albicans. Colony-forming units of C. albicans on the denture surface were counted after spreading on agar plate. The denture base resin was treated with the spent culture media for 30days, after which the denture surface roughness was analyzed with an atomic force microscope. L. rhamnosus and L. casei exhibited stronger antifungal activity than other probiotics. The spent culture medium of L. rhamnosus and L. casei exhibited the antifungal activity against blastoconidia and biofilm of C. albicans. L. rhamnosus and L. casei showed the antifungal activity against Candida biofilm, and the biofilm of L. rhamnosus and L. casei inhibited formation of Candida biofilm on denture surface. Neither of the probiotics affected the surface roughness of the denture base resin. L. rhamnosus and L. casei may be the ideal probiotics for the prevention and treatment of denture-related stomatitis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Effects of Reinforcement on Denture Strain in Maxillary Implant Overdentures: An In Vitro Study Under Various Implant Configurations.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Maxillary implant overdentures are often designed without palatal coverage to maximize wearer comfort. Although palateless dentures have been reported to be less rigid than conventional dentures, and require reinforcement to prevent complications, there is little documentation about the effects of such reinforcement. The purpose of this study was to examine the effects of reinforcement on the strain on maxillary implant overdentures supported by implants in a variety of configurations. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar area was fabricated. Five types of experimental overdentures, with and without reinforcement, were fabricated, and two strain gauges were attached at the anterior midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain on the denture was measured. The measurements were compared using the Kruskal-Wallis test (P = .05). On both the labial and palatal sides, the strain on the palateless dentures with reinforcement was significantly lower than the strain on palateless dentures without reinforcement in all implant configurations (P < .05). The labial strain on the palateless dentures with reinforcement was almost as low as the labial strain on dentures with palatal coverage in most implant configurations. Reinforcement of a palateless implant overdenture with residual ridge reinforcement and a palatal bar could reduce the strain in the anterior midline to almost the same level as a denture with palatal coverage. This type of reinforcement may prevent prosthetic and implant complications.

  5. Anterior implant-supported overdentures.

    PubMed

    Ben-Ur, Z; Gorfil, C; Shifman, A

    1996-09-01

    Retention of complete mandibular dentures can be successfully achieved by means of an implant-retained or natural tooth-retained bar and clip system in the anterior segment of the mandible. The same design principles hold true for both methods of anchoring the retentive bar. These retentive elements must be constructed to allow some freedom of movement around a fulcrum line designed to be perpendicular to the sagittal plane.

  6. Satisfaction in complete denture wearers with and without adhesives: A randomized, crossover, double-blind clinical trial

    PubMed Central

    Torres-Sánchez, Carlos; Montoya-Salazar, Vanessa; Gutierrez-Pérez, Jose-Luis; Jimenez-Castellanos, Emilio

    2018-01-01

    Background The purpose of this study was to compare the satisfaction of patients regarding retention, stability and accumulation of particles with a randomized, double-blind crossed method in users with complete dentures with and without adhesive. Material and Methods Seventeen edentulous individuals were randomized and received new upper and lower complete dentures. After a period of adaptation, they participated in some masticatory tests and clinical revisions, after use the protheses with and without the use of two denture adhesives: Adhesive A (Fittydent, Fittydent International GmbH) and adhesive B (Corega, GlaxoSmithKline) at 0, 7 and 14 days. Satisfaction was measured immediately after each test through a survey using a VAS scale (0-10) and data were analyzed with McNemar’s test with Bonferroni correction. Results The results showed significant differences (p<.01) between the study groups with adhesive A - B and the group without adhesive, but no significant differences were found between the two stickers for any of the variables studied. Conclusions Complete denture adhesives significantly improved the satisfaction of patients because a better retention, stability and less accumulation of particles of the food substitute between the denture and the mucosa is obtained compared with non-use of complete denture adhesives. Key words:Complete dentures, patient satisfaction, denture adhesives, clinical trials. PMID:29946414

  7. Variations in Flexural Strength of Heat-polymerized Acrylic Resin after the Usage of Denture Cleansers.

    PubMed

    Ragher, Mallikarjuna; Vinayakumar, G; Patil, Sanketsopan; Chatterjee, Aishwarya; Mallikarjuna, D M; Dandekeri, Savita; Swetha, V; Pradeep, M R

    2016-04-01

    The objective of this study was to evaluate and compare changes in the flexural strength of heat-cured denture base resins when treated using denture cleansers. A total of 40 specimens with dimension 65 mm length, 10 mm width, and 3 mm thickness were prepared as per ISO 1567 specification. A total of 10 specimens were immersed in distilled water to be used as control. Of the remaining 30 samples, 10 were treated with Clinsodent, 10 with VI-Clean, and 10 with Clanden denture cleansers. Specimens in each group were subjected to three-point flexural load in universal testing machine at a cross-head speed of 5 mm/min. The peak load (N) was recorded and flexural strength was calculated. The findings were analyzed using Kruskal-Wallis analysis of variance and Mann-Whitney test. Heat-cured denture base resin selected for this study showed significant difference in flexural strength after immersion in denture cleansers Clinsodent, VI-Clean, and Clanden solutions, when compared with the control group. Findings of this study showed that denture cleansers altered the flexural strength of heat polymerized acrylic resins that endured soaking cycles which simulated 180 days of use. Hence, denture cleansers should be used with caution, once a day after brushing the dentures. It is advisable for patients to follow the manufacturer's instructions.

  8. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    PubMed Central

    Creugers, N. H. J.; Witter, D. J.; Van 't Spijker, A.; Gerritsen, A. E.; Kreulen, C. M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches without extension (n = 74) and with subjects who had worn a mandibular extension removable partial denture in the past (n = 19). Subjects with complete dentitions (n = 72) were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function. PMID:20671961

  9. Lenticular card: a new method for denture identification.

    PubMed

    Colvenkar, Shreya S

    2010-01-01

    The need for denture marking is important for forensic and social reasons in case patients need to be identified individually. Majority of the surface marking and inclusion techniques are expensive, time consuming, and do not permit the incorporation of large amounts of information. In this article, the method to include a lenticular identification card stood out from the currently available denture marking methods in various ways. The lenticular card stores the patient's information has two or more images that can be viewed by changing the angle of view. The maxillary denture was processed according to the manufacturer's instructions. The lenticular identification card was incorporated in the external posterior buccal surface of the maxillary denture using salt and pepper technique. For testing of durability, denture with the identifier was placed in water for up to 4 months. The proposed method is simple, cheap, and can store a large amount of information, thus allowing quick identification of the denture wearer. The labels showed no sign of fading or deterioration.

  10. Forensic odontology: A prosthodontic view

    PubMed Central

    Gosavi, Sulekha; Gosavi, Siddharth

    2012-01-01

    The most common role of the forensic dentist is the identification of deceased individuals. Dental identifications have always played a key role in natural and manmade disaster situations, and in particular, the mass casualties normally associated with aviation disasters. Because of the lack of a comprehensive fingerprint database, dental identification continues to be crucial in the world. An all-acrylic resin appliance such as a full denture or an all-acrylic partial denture (or orthodontic appliance), prior to delivery, could be inscribed with the patient's full name on a substrate (paper, metal) and sealed inconspicuously into the surface of a denture by various processes. It has been noted by several authors that in many cases of air disaster where the limbs are completely burnt off, some denture materials survive, especially the posterior part of acrylic dentures and metal-based dentures. Thus, marked dental prostheses (full and partial dentures, mouthguards and removal orthodontic appliances) would lead to rapid identification in the event of accidents and disaster. PMID:23087581

  11. Bactericidal efficacy of glycine-type amphoteric surfactant as a denture cleaner and its influence on properties of denture base resins.

    PubMed

    Hashiguchi, Makiko; Nishi, Yasuhiro; Kanie, Takahito; Ban, Seiji; Nagaoka, Eiichi

    2009-05-01

    The bactericidal efficacy of 1.00-4.50% glycine-type amphoteric surfactant (Gly) was evaluated by measuring its microorganism removal rate in denture plaque. Physical and mechanical properties such as surface roughness, color difference, and bending strength of two different denture base resins were determined before and after cleaning in Gly solutions, a commercial denture cleaner, and tap water. The microorganism removal rates of all the Gly solutions were higher than those of a commercial enzymatic denture cleaner (Polident) (p>0.05). The removal rate of Candida spp. by Polident was not significantly different from the removal rate using water. Changes in the surface roughness and color difference among the specimens were slight. There were no significant differences in the bending strengths of the two resins for all concentrations of Gly solution (p>0.05). These results suggested that glycine-type amphoteric surfactant solution may be effective as a denture cleaner in conjunction with an ultrasonic cleaning device.

  12. Denture Care: How Do I Clean Dentures?

    MedlinePlus

    ... Avoid stiff-bristled brushes, strong cleansers and harsh toothpaste, as these are too abrasive and can damage your dentures. Whitening toothpastes. Toothpastes advertised as whitening pastes often contain peroxide, ...

  13. Dissolution of cement, root caries, fracture, and retrofit of post and cores.

    PubMed

    Rosen, H

    1998-10-01

    Fixed partial denture abutments severely damaged by dental caries or fracture present a challenge to the dentist. The fixed partial denture may need to be removed for endodontic treatment with post and core fabrication. Frequently, the existing fixed partial denture can be recycled as a provisional restoration. Retrofitting the post and core greatly improves the stabilization of the interim as well as the remake of the definitive fixed partial denture. This article describes a chair side procedure for retrofitting posts and cores and, at the same appointment, converting the original fixed partial denture to an effective provisional restoration.

  14. Tensile strength and water absorption of alumina filled poly (methyl methacrylate) denture base material.

    PubMed

    Nizam, A; Mohamed, S H; Arifin, A; Mohd Ishak, Z A; Samsudin, A R

    2004-05-01

    The aim of this study was to evaluate the tensile properties and water absorption of denture base material prepared from high molecular weight poly methyl methacrylate (PMMA) and alumina (Al2O3) as particulate filler. Specimens for mechanical testing were prepared by adding composite powder to the monomer followed by hand mixing as in dental laboratory procedure. The tensile strength of the prepared denture base material was slightly higher than commercial denture base material, while the water absorption was almost the same for all formulation of denture base materials.

  15. A development of visible light cured FRP plate denture.

    PubMed

    Kimura, H; Teraoka, F

    1990-12-01

    A FRP denture base, which was made from visible light curing prepreg, was developed. The visible light cured FRP denture base had advantages with respect to an adequate strength, bonding strength of acrylic base resin, esthetic properties and ease to manipulation. The matrix resin of Bis-GMA/UDMA/3 G at 48/48/4 was determined from the results of the bending test and manipulation processing. The sateen weave's glasscloth was used for the reinforcement of the prepreg. The adaptability of the FRP plate denture was better than that of the resin base denture constructed with microwave heating.

  16. The effectiveness of adhesives on the retention of mandibular free end saddle partial dentures: An in vitro study.

    PubMed

    Quiney, Daniel; Nishio Ayre, Wayne; Milward, Paul

    2017-07-01

    Existing in vitro methods for testing denture adhesives do not fully replicate the complex oral geometries and environment; and in vivo methods are qualitative, prone to bias and not easily reproducible. The purpose of this study was to develop a novel, quantitative and more accurate model to test the effect of adhesives on the retentive force of mandibular free end saddle partial dentures. An in vitro model was developed based on an anatomically accurate cast of a clinical case. Experimentally, the amount of adhesive was varied (0.2g-1g) and the tensile force required for displacement was measured. Different commercially available adhesives were then tested at the optimum volume using the in vitro model. A 3D finite element model of the denture was used to assess how the forces to induce denture displacement varied according to the position of the force along the saddle length. The mass of adhesive was found to significantly alter retention forces, with 0.4-0.7g being the optimum range for this particular scenario. Use of adhesives significantly improved mandibular free end saddle partial denture retention with the worst performing adhesive increasing retention nine-fold whilst the best performing adhesive increased retention twenty three-fold. The finite element model revealed that 77% more force was required to displace the denture by positioning forces towards the mesial end of the saddle compared to the distal end. An in vitro denture adhesive model was developed, which demonstrated that mass of adhesive plays a significant role in enhancing denture retention and supported the design principle of placing as few teeth as clinically necessary on the distal end of the free end saddles. Limiting the position of teeth on free end saddles to the mesial and mid portion of the saddle will reduce displacements caused by mastication. The movement of mandibular free end saddle partial dentures can be restricted with the use of denture adhesives. Altering the mass of adhesive used can further improve the retention of mandibular free end saddle partial dentures for patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Efficacy of bone substitute material in preserving volume when placing a maxillary immediate complete denture: study protocol for the PANORAMIX randomized controlled trial.

    PubMed

    Rignon-Bret, Christophe; Hadida, Alain; Aidan, Alexis; Nguyen, Thien-Huong; Pasquet, Gerard; Fron-Chabouis, Helene; Wulfman, Claudine

    2016-05-20

    Bone preservation is an essential issue in the context of last teeth extraction and complete edentulism. The intended treatment, whether a complete denture or an implant placement, is facilitated with a voluminous residual ridge. Bone resorption after multiple extractions has not been as well studied as the bone resorption that occurs after the extraction of a single tooth. Recent advances in bone substitute materials have revived this issue. The purpose of this study is to evaluate the interest in using bone substitute material to fill the socket after last teeth extraction in a maxillary immediate complete denture procedure compared with the conventional protocol without socket filling. A randomized, controlled, clinical trial was designed. The 34 participants eligible for maxillary immediate complete denture were divided into two groups. Complete dentures were prepared despite persistence of the last anterior teeth. The control group received a conventional treatment including denture placement immediately after extractions. In the experimental group, in addition to the immediate denture placement, a xenograft bone-substitute material (Bio-Oss Collagen®) was placed in the fresh sockets. The primary outcome of the study is to compare mean bone ridge height loss 1 year after maxillary immediate complete denture placement, with or without bone-substitute material, in incisor and canine sockets. The secondary outcomes are to compare the average bone ridge height and width loss for each extraction site. An original quantitative evaluation method using cone beam computed tomography was designed for reproducible measurements, with a radio-opaque denture duplicate. Two independent operators perform the radiologic measurements. The immediate complete denture technique limits bone resorption in multiple extraction situations and thus allows better denture retention and better options for implant placement. To compare the benefit of using any bone socket-filling material, we proposed a quantitative evaluation protocol of resorption in the specific case of the last anterior maxillary teeth extraction with immediate denture placement. ClinicalTrials.gov, NCT02120053 . Registered on 18 April 2014.

  18. Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

    PubMed

    McLaughlin, J Bryan; Ramos, Van; Dickinson, Douglas P

    2017-11-14

    To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from the use of injection molding compared to CAD/CAM and compression molding. © 2017 by the American College of Prosthodontists.

  19. Influence of length and diameter of implants associated with distal extension removable partial dentures.

    PubMed

    Verri, Fellippo Ramos; Pellizzer, Eduardo Piza; Rocha, Eduardo Passos; Pereira, João Antônio

    2007-09-01

    The aim of this study was to evaluate the influence of the length and diameter of the implant incorporated under the saddle of a distal-extension removable partial denture, acting as support. Six hemi-mandibular models were made with the presence of left inferior cuspid and first bicuspid, with the following differences: model A, without removable partial denture; model B, removable partial denture only; model C, removable partial denture and implant of 3.75 x x mm; model D, removable partial denture and implant of 3.75 x x3 mm; model E, removable partial denture and implant of 5 x x mm; and model F, removable partial denture and implant of 5 x x3 mm. These models were designed with the aid of AutoCAD 2000 (Autodesk, Inc., San Rafael, CA) and processed for finite element analysis by ANSYS 5.4 (Swanson Analysis Systems, Houston, PA). The loads applied were 50 N vertical on each cuspid point. It was noted that the presence of the removable partial denture overloaded the supporting tooth and other structures. The introduction of the implant reduced tensions, mainly at the extremities of the edentulous edge. Both the length and diameter tended to reduce tensions as their dimensions increased. Increasing the length of the implant had a great influence on the decrease of displacement and von Mises tension values. Increasing the diameter of the implant had a great influence on the decrease of von Mises tension values, but did not influence the displacement values. According to the results of this study, it is a good choice to use the greater and larger implant possible in the association between implant and distal extension removable partial denture.

  20. Effectiveness of Photodynamic Therapy for the Inactivation of Candida spp. on Dentures: In Vitro Study

    PubMed Central

    Mima, Ewerton Garcia de Oliveira; Ribeiro, Daniela Garcia; Dovigo, Livia Nordi; Vergani, Carlos Eduardo; Bagnato, Vanderlei Salvador

    2011-01-01

    Abstract Objective: This in vitro study evaluated the effectiveness of photodynamic therapy (PDT) for the inactivation of different species of Candida on maxillary complete dentures. Background data: The treatment of denture stomatitis requires the inactivation of Candida spp. on dentures. PDT has been reported as an effective method for Candida inactivation. Methods: Reference strains of C. albicans, C. glabrata, C. tropicalis, C. dubliniensis and C. krusei were tested. Thirty-four dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated with one of the strains and incubated at 37°C for 24 h. Dentures submitted to PDT (P+L+) were individually sprayed with 50 mg/L of Photogem® (PS) and, after 30 min, illuminated by LED light for 26 min (37.5 J/cm2). Additional dentures were treated only with PS (P+L-) or light (P-L+) or neither (P-L-). Samples of serial dilutions were spread on Sabouraud dextrose agar and incubated at 37°C for 48 h. The colonies were counted and the values of log (cfu/mL) were analyzed by Kruskall-Wallis and Dunn tests (p<0.05). Results: For all species of Candida, PDT resulted in significant reduction (p<0.05) of cfu/mL values from dentures when compared with P-L- (reductions from 1.73 to 3.99 log10). Significant differences (p<0.05), but lower reductions, were also observed for P+L- and P-L+when compared with P-L- for some species of Candida. Conclusions: PDT was an effective method for reducing Candida spp. on dentures. PMID:21916614

  1. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    PubMed

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p < 0.001). A 2 mm mean increase in OVD was observed in 47.7% of the dentures with < 6 occlusal contact changes and 88.9% of the dentures with ≥ 6 occlusal contact changes (p < 0.003). A significant change in the number of occlusal contacts was associated with an OVD increased up to two times. The short curing technique seems to be related to the decreased occlusal contacts and increased OVD. CLINICAL SIGNIFICANCES: More time is needed to adjust the occlusal errors of this method, because it has a negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  2. Rechargeable infection-responsive antifungal denture materials.

    PubMed

    Cao, Z; Sun, X; Yeh, C-K; Sun, Y

    2010-12-01

    Candida-associated denture stomatitis (CADS) is a significant clinical concern. We developed rechargeable infection-responsive antifungal denture materials for potentially managing the disease. Polymethacrylic acid (PMAA) was covalently bound onto diurethane dimethacrylate denture resins in the curing step. The PMAA resins bound cationic antifungal drugs such as miconazole and chlorhexidine digluconate (CG) through ionic interactions. The anticandidal activities of the drug-containing PMAA-resin discs were sustained for a prolonged period of time (weeks and months). Drug release was much faster at acidic conditions (pH 5) than at pH 7. Drugs bound to the denture materials could be "washed out" by treatment with EDTA, and the drug-depleted resins could be recharged with the same or a different class of anticandidal drugs. These results suggest clinical potential of the newly developed antifungal denture materials in the management of CADS and other infectious conditions.

  3. Wear rates of artificial denture teeth opposed by natural dentition.

    PubMed

    Douglas, W H; Delong, R; Pintado, M R; Latta, M A

    1993-01-01

    The wear rate of polymeric or composite-based artificial denture teeth on fixed, removable and implant prostheses is important in the maintenance of cuspal form, masticatory efficiency and occlusal stability. A servo-hydraulic based artificial mouth in which an occlusion was established between artificial denture teeth, and the palatal cusp of a human maxillary third molar was established and used to assess the wear resistance of 5 artificial denture tooth materials. Volumetric wear was determined for Dentsply Trublend SLM, Dentsply IPN, Vita Vitapan, Ivoclar Orthotyp and Ivoclar Orthosit denture teeth. Scanning electron microscopy was also done to assess the textural character of the wear facets of each denture tooth sample. The lowest volume loss was observed for Trublend SLM followed by IPN, Orthotyp, Vitapan and Orthosit. Textural assessment of the materials was consistent with the objective wear data.

  4. Inflammatory papillary hyperplasia: A systematic review

    PubMed Central

    Gual-Vaqués, Patricia; Jané-Salas, Enric; Egido-Moreno, Sonia; Ayuso-Montero, Raúl; Marí-Roig, Antoni

    2017-01-01

    Introduction Inflammatory papillary hyperplasia (IPH) is a benign lesion of the palatal mucosa. It is usually found in denture-wearers but also has been reported in patients without a history of use of a maxillary prosthesis use. Objetives The aim of this study is to review the literature to assess the prevalence of denture stomatitis and inflammatory papillary hyperplasia and the etiological factors associated. Material and Methods A search was carried out in PubMed (January 2005 to October 2015) with the key words “inflammatory papillary hyperplasia”, “denture stomatitis”, “granular stomatitis” and “Newton’s type III” The inclusion criteria were studies including at least a sample of 50 apparently healthy patients, articles published from 2005 to 2015 written in English. The exclusion criteria were reviews and non-human studies. Results Out of the 190 studies obtained initially from the search 16 articles were selected to be included in our systematic review. The prevalence of denture stomatitis was 29.56% and 4.44% for IPH. We found 5 cases of denture stomatitis among non-denture-wearer individuals. All IPH cases were associated with the use of prosthesis. Smoking and continued use of ill-fitting dentures turned out to be the most frequent risk factors for developing IPH. Conclusions IPH is a rare oral lesion and its pathogenesis still remains unclear. Its presentation among non-denture-wearers is extremely unusual. Key words:Inflammatory papillary hyperplasia, denture stomatitis, prevalence, granular stomatitis, Newton’s type III stomatitis. PMID:27918740

  5. VINEGAR AS AN ANTIMICROBIAL AGENT FOR CONTROL OF Candida spp. IN COMPLETE DENTURE WEARERS

    PubMed Central

    Pinto, Telma Maria Silva; Neves, Ana Christina Claro; Leão, Mariella Vieira Pereira; Jorge, Antonio Olavo Cardoso

    2008-01-01

    The use of denture is known to increase the carriage of Candida in healthy patients, and the proliferation of Candida albicans strains can be associated with denture-induced stomatitis. The aim of this study was to evaluate the use of vinegar as an antimicrobial agent for control of Candida spp. in complete upper denture wearers. Fifty-five patients were submitted to a detailed clinical interview and oral clinical examination, and were instructed to keep their dentures immersed in a 10% vinegar solution (pH less than 3) overnight for 45 days. Before and after the experimental period, saliva samples were collected for detection of Candida, counting of cfu/mL and identification of species by phenotypical tests (germ tube formation, chlamidoconidia production, and carbohydrate fermentation and assimilation). The results were analyzed using Spearman's correlation and Student's t-test (p≤0.05). Candida yeasts were present in 87.3% of saliva samples before the treatment. A significant reduction was verified in CFU/mL counts of Candida after treatment. A positive correlation between Candida and denture stomatitis was verified, since the decrease of cfu/mL counts was correlated with a reduction in cases of denture stomatitis. Although it was not able to eliminate C. albicans, the immersion of the complete denture in 10% vinegar solution, during the night, reduced the amounts (cfu/mL) of Candida spp. in the saliva and the presence of denture stomatitis in the studied patients. PMID:19082396

  6. Color stability of different denture teeth materials: an in vitro study.

    PubMed

    Mutlu-Sagesen, L; Ergün, G; Ozkan, Y; Bek, B

    2001-09-01

    The aim of this in vitro study was to compare the color stability of commercially available porcelain, reinforced acrylic, and conventional acrylic denture teeth materials used in removable prostheses. Two brands of porcelain (Unilux-Enta Lactona-Holland and Vivoperl-Ivoclar-Liechtenstein), 2 brands of reinforced acrylic (Optodent-Bayer-Germany and Ivolek-Ivoclar-Liechtenstein), and 2 brands of conventional acrylic (Isodent-Güney Diş Deposu-Turkey and Samed-Turkey), were made, for a total of 6 different denture teeth groups. Denture teeth were subjected to 3 staining solutions (filtered coffee, tea, and cola) and distilled water. From each group of denture teeth, 4 sets of maxillary anterior denture teeth were immersed in each of the 4 solutions. The color values of denture teeth were measured colorimetrically with the Gardner XL 20 Tristimulus Colorimeter (Gardner Lab. Inc., Bethesda, Maryland, USA). Color changes were characterized in the CIEL*a*b* color space. Color change values were determined after 1 day, 1 week, 2 weeks, and 4 weeks. The color difference values were calculated and then evaluated by two-way ANOVA statistically. The filtered coffee solution was found to be more chromogenic than the other 2 staining solutions, while porcelain denture teeth materials were more color stable. Assuming the color change of deltaE* < 1.0 as a discernible limit and deltaE* = 3.3 as an acceptable value, the filtered coffee, tea, and cola had slight staining effects on all 6 groups of denture teeth.

  7. The importance of a two-step impression procedure for complete denture fabrication: a systematic review of the literature.

    PubMed

    Regis, R R; Alves, C C S; Rocha, S S M; Negreiros, W A; Freitas-Pontes, K M

    2016-10-01

    The literature has questioned the real need for some clinical and laboratory procedures considered essential for achieving better results for complete denture fabrication. The aim of this study was to review the current literature concerning the relevance of a two-step impression procedure to achieve better clinical results in fabricating conventional complete dentures. Through an electronic search strategy of the PubMed/MEDLINE database, randomised controlled clinical trials which compared complete denture fabrication in adults in which one or two steps of impressions occurred were identified. The selections were made by three independent reviewers. Among the 540 titles initially identified, four studies (seven published papers) reporting on 257 patients evaluating aspects such as oral health-related quality of life, patient satisfaction with dentures in use, masticatory performance and chewing ability, denture quality, direct and indirect costs were considered eligible. The quality of included studies was assessed according to the Cochrane guidelines. The clinical studies considered for this review suggest that a two-step impression procedure may not be mandatory for the success of conventional complete denture fabrication regarding a variety of clinical aspects of denture quality and patients' perceptions of the treatment. © 2016 John Wiley & Sons Ltd.

  8. The adhesive strength and initial viscosity of denture adhesives.

    PubMed

    Han, Jian-Min; Hong, Guang; Dilinuer, Maimaitishawuti; Lin, Hong; Zheng, Gang; Wang, Xin-Zhi; Sasaki, Keiichi

    2014-11-01

    To examine the initial viscosity and adhesive strength of modern denture adhesives in vitro. Three cream-type denture adhesives (Poligrip S, Corect Cream, Liodent Cream; PGS, CRC, LDC) and three powder-type denture adhesives (Poligrip Powder, New Faston, Zanfton; PGP, FSN, ZFN) were used in this study. The initial viscosity was measured using a controlled-stress rheometer. The adhesive strength was measured according to ISO-10873 recommended procedures. All data were analyzed independently by one-way analysis of variance combined with a Student-Newman-Keuls multiple comparison test at a 5% level of significance. The initial viscosity of all the cream-type denture adhesives was lower than the powder-type adhesives. Before immersion in water, all the powder-type adhesives exhibited higher adhesive strength than the cream-type adhesives. However, the adhesive strength of cream-type denture adhesives increased significantly and exceeded the powder-type denture adhesives after immersion in water. For powder-type adhesives, the adhesive strength significantly decreased after immersion in water for 60 min, while the adhesive strength of the cream-type adhesives significantly decreased after immersion in water for 180 min. Cream-type denture adhesives have lower initial viscosity and higher adhesive strength than powder type adhesives, which may offer better manipulation properties and greater efficacy during application.

  9. Relevance of Variations in the Opposing Dentition for the Functionality of Fixed and Removable Partial Dentures: A Systematic Review

    PubMed Central

    Pommer, Bernhard; Krainhöfner, Martin; Watzek, Georg; Tepper, Gabor; Dintsios, Charalabos-Markos

    2012-01-01

    The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a “biometric quality” tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a) the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b) the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture. PMID:23193407

  10. Evaluation of the utility of cephalometric parameters in constructing complete denture. Part I: placement of posterior teeth.

    PubMed

    Bassi, F; Deregibus, A; Previgliano, V; Bracco, P; Preti, G

    2001-03-01

    Various types of parameters, including cephalometric ones, have been used in the construction of complete denture. This study aimed to evaluate the utility of cephalometric parameters for this purpose. The position of the posterior teeth in a group of 42 edentulous patients, successfully rehabilitated with complete denture according to clinical parameters, was evaluated by cephalometrics. The following were determined: vertical dimension of occlusion (VDO); orientation of the occlusal plane; and subdivision of the denture space. The cephalometric parameters do not correspond to the clinical positioning of the posterior teeth in successful rehabilitation with complete denture.

  11. Contribution of the palate to denture base support: an in vivo study.

    PubMed

    Ando, Takanori; Maeda, Yoshinobu; Wada, Masahiro; Gonda, Tomoya

    2014-01-01

    The aim of this study was to examine the contribution of the palate to denture base support. Four subjects with tooth- or implant-supported maxillary overdentures were enrolled. Recordings (strain values converted to load values) were performed using miniature strain gauges and force transducers for the following conditions: metal framework only (A), denture base with full palatal coverage (B), and denture base without palatal coverage (C). The palatal-supporting ratio (PSR) was calculated using the equation PSR = (B - C) / A. The PSR values were less than 10% in all subjects, suggesting that the palate plays a minimal role in denture base support.

  12. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes.

    PubMed

    Bidra, Avinash S; Farrell, Kimberly; Burnham, David; Dhingra, Ajay; Taylor, Thomas D; Kuo, Chia-Ling

    2016-05-01

    Presently, no studies have evaluated clinical outcomes or patient-centered outcomes for complete dentures fabricated with computer-aided design and computer aided manufacturing (CAD/CAM) technology. The purpose of this prospective cohort pilot study was to evaluate the clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated in 2 visits. Twenty participants with an existing set of maxillary complete dentures opposing either mandibular complete dentures or implant-retained overdentures that required replacement were recruited in this study. A 2-visit duplicate denture protocol was used to fabricate 40 arches of monolithic dentures with CAD/CAM technology. A 100-mm visual analog scale (VAS) instrument was then used to record 12 outcomes at baseline and at 1-year follow-up. Predetermined values were assigned to grade the VAS rating of each outcome as favorable (70.1-100) and unfavorable (≤70). Favorable ratings were sub-divided as excellent (90.1-100), good (80.1-90), and fair (70.1-80). The clinical outcomes were evaluated independently by 2 experienced prosthodontists at baseline and at 1-year follow-up. Patients evaluated the corresponding patient-centered outcomes during the same time intervals. Additional descriptive variables were also recorded. Each clinical and patient-centered outcome was summarized by medians and ranges. Differences in all ratings recorded at baseline and at 1 year were tested by 1-sided sign test (α=.05). Of 20 participants, 3 were lost to follow-up, and 3 were unsatisfied with the digital dentures and withdrew from the study. These 3 participants were considered treatment failures. Of the 14 remaining participants, 9 had implant-retained mandibular overdentures, and 5 had conventional mandibular complete dentures. For clinical outcomes, the 12 studied outcomes were favorably evaluated by the 2 prosthodontist judges at the 1-year follow-up. Evaluations showed minimal differences between baseline and 1 year. An average of 5 emails (0-11) per patient were sent to the laboratory technicians to communicate the improvisation the CAD design of the dentures. An average of 3.3 denture adjustments were needed after insertion (0-10) during the 1-year period. For patient-centered outcomes, median ratings of all 14 participants indicated each of the 12 studied outcomes was favorable at the 1-year recall. Statistically significant improvements in patient ratings from baseline to 1 year were observed for the absence of denture sore spots and treatment time to make the dentures (P<.05). Minor complications related to loss of retention, excessive wear of teeth and the need for additional visits were observed in 5 participants. No other adverse clinical outcomes related to the CAD/CAM dentures were noted in the 14 evaluated participants, and all dentures were intact and in good condition at the 1-year follow-up. Clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated using a 2-visit protocol were evaluated favorably at a 1-year follow-up. However, the proportion of excellent and good ratings for overall satisfaction and assessment was higher for patients than clinicians. A considerable amount of the clinician's time and effort was devoted to aiding in the digital process for the fabrication of CAD/CAM dentures. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Comparative stain removal properties of four commercially available denture cleaning products: an in vitro study.

    PubMed

    Alam, M; Jagger, R; Vowles, R; Moran, J

    2011-02-01

    Formulations of commercially available denture cleaners vary widely. Unfortunately, comparative data to suggest which products are the most effective can become invalid as newer products are introduced or formulations are changed. The aim of this in vitro study was to measure the stain removal properties of four currently available denture cleaners. Stain was deposited on multi-well polystyrene saliva coated microplates using multiple chlorhexidine and tea solutions. Following drying, each stained well was exposed to a solution of denture cleaner, dried again and the amount of stain remaining measured using a microplate reader. The cleaning procedure was repeated with further multiple exposures of the wells to solutions of the denture cleaners. All denture cleaners removed stain better than water used as a control. At five cleaning cycles only one of the cleaners (Superdrug Cleaning Powder) had removed 100% of the stain. At 30 cycles three of the cleaners had removed 100% of the stain. All the commercial denture cleaners removed stain. Superdrug Cleaning Powder, which contains sodium percarbonate and sodium lauryl sulphate, was particularly effective. © 2010 John Wiley & Sons A/S.

  14. Potential pathogenic aspects of denture plaque.

    PubMed

    Coulthwaite, L; Verran, J

    2007-01-01

    Oral health status declines with age and as a result the need for removable prostheses increases. Oral health is a reflection of one's general health, affecting the ability of an individual to eat and speak, and contributes significantly to a sense of confidence and well-being. Currently, there are 15 million denture wearers in the UK, representing a significant consumer base and a special healthcare consideration. The microbiology of denture plaque has received little attention in comparison with dental plaque, yet it differs in location and composition. Denture plaque and poor denture hygiene is associated with stomatitis (Candida infection), may also serve as a reservoir of potentially infectious pathogens, and may contribute to oral malodour and to caries and periodontitis in people who have remaining natural teeth. Oral bacteria have been implicated in bacterial endocarditis, aspiration pneumonia, gastrointestinal infection and chronic obstructive pulmonary disease, among others, and dentures offer a reservoir for microorganisms associated with these infections. An effective oral hygiene regimen is important to control denture plaque biofilm and contributes to the control of associated oral and systemic diseases.

  15. Prosthodontic Rehabilitation of Patients with Bell's Palsy: Our Experience.

    PubMed

    Rajapur, Anand; Mitra, Nirban; Prakash, V Jeevan; Rah, Sajad Ahmad; Thumar, Sagar

    2015-01-01

    Bell's palsy is an idiopathic unilateral lower motor neuron paresis or paralysis of the facial nerve of sudden onset. It involves loss of muscular control on the affected side of the face. This paper reports the prosthodontic management of patients with Bell's palsy and also describes a technique to stabilize the jaw movements in complete denture patients using interim dentures. A 65-year-old male edentulous patient and a 55-year-old female edentulous patient reported to the department of prosthodontics to get their missing teeth replaced. They both gave history of facial paralysis and were diagnosed for Bell's palsy. Interim training dentures with flat occlusal tables were fabricated first to correct and stabilize their mandibular movements. During initial 4 weeks, there was poor functioning of the interim dentures. Gradually by 8(th) week the patients started stabilizing the interim dentures and were functional. After observing the improvement when the patients had no pain and could stabilize and use the treatment dentures successfully, definitive complete dentures were fabricated. This case report presents a systematic approach to successively rehabilitate edentulous patients with Bell's palsy.

  16. Prosthodontic Rehabilitation of Patients with Bell’s Palsy: Our Experience

    PubMed Central

    Rajapur, Anand; Mitra, Nirban; Prakash, V Jeevan; Rah, Sajad Ahmad; Thumar, Sagar

    2015-01-01

    Bell’s palsy is an idiopathic unilateral lower motor neuron paresis or paralysis of the facial nerve of sudden onset. It involves loss of muscular control on the affected side of the face. This paper reports the prosthodontic management of patients with Bell’s palsy and also describes a technique to stabilize the jaw movements in complete denture patients using interim dentures. A 65-year-old male edentulous patient and a 55-year-old female edentulous patient reported to the department of prosthodontics to get their missing teeth replaced. They both gave history of facial paralysis and were diagnosed for Bell’s palsy. Interim training dentures with flat occlusal tables were fabricated first to correct and stabilize their mandibular movements. During initial 4 weeks, there was poor functioning of the interim dentures. Gradually by 8th week the patients started stabilizing the interim dentures and were functional. After observing the improvement when the patients had no pain and could stabilize and use the treatment dentures successfully, definitive complete dentures were fabricated. This case report presents a systematic approach to successively rehabilitate edentulous patients with Bell’s palsy. PMID:26668488

  17. Long-term clinical and prosthetic outcomes of soft liner and clip attachments for bar/implant overdentures: a randomised controlled clinical trial.

    PubMed

    ELsyad, M A; Shaheen, N H; Ashmawy, T M

    2017-06-01

    Long-term clinical and prosthetic outcomes of soft liner attachments for bar/implant overdentures were not sufficiently investigated. The aim of this trial was to evaluate clinical and prosthetic outcomes of resilient liner and clip attachments for bar/implant-retained mandibular overdenture after 7 years. Thirty edentulous male participants received two implants in the canine areas of the mandible. Three months later, implants were splinted with a resilient bar. Mandibular overdentures were connected to the bars with either clip (CR group, n = 15) or resilient liner (RR group, n = 15) attachments. Plaque index (PI), gingival index (GI), probing depth (PD), vertical bone loss (VBL), horizontal bone loss (HBLO) and prosthetic complications (PCs) were evaluated at denture delivery (T0), 6 (T 6m ), 12 (T1), 24 (T2), 36 (T3), 48 (T4), 60 (T5), 72 (T6) and 84 (T7) months after insertion. PI and GI increased significantly with time for CR and decreased significantly for RR (P < 0·001). PD increased at T1 (CR) and T6 m (RR) and then decreased thereafter (P < 0·05). VBL increased significantly with time in both groups (P < 0·005). HBLO increased at T2 (CR) and T1 (RR) and then decreased thereafter. CR recorded significant higher PI, GI, PD, VBLO and HBLO compared to RR at all observation times (P < 0·042). The survival rates were 96·6% and 100% for CR and RR after 7 years. The most common PCs for CR and RR were clip wears and separation of the resilient liner from the denture base, respectively. Within the limitations of this study, resilient liner attachments are recommended for bar/implant-retained mandibular overdentures than clip attachments in terms of peri-implant tissue health and prosthetic complications after 7 years. © 2017 John Wiley & Sons Ltd.

  18. A System Approach to Navy Medical Education and Training. Appendix 45. Competency Curricula for Dental Prosthetic Assistant and Dental Prosthetic Technician.

    DTIC Science & Technology

    1974-08-31

    Removable Partial Dentures ..................... 34 XI. Fixed Partial Denture Construction .. ........ 35 l. Construct Master Cast with Removable...Dies . . . 36 2. Construct Patterns for Fixed Partial Dentures .. . ..... 37 3. Spruing and Investing oeu . . . 38 4. Wax Elimination and Casting...42 S. Re3in Jacket Crowns . . ............ 43 9. Temporary Crowns and Fixed Partial Dentures . . 44 10. Post and Core Techniques . . o

  19. Erratum to: Application of addition-cured silicone denture relining materials to adjust mouthguards.

    PubMed

    Fukasawa, Shintaro; Churei, Hiroshi; Chowdhury, Ruman Uddin; Shirako, Takahiro; Shahrin, Sharika; Shrestha, Abhishekhi; Wada, Takahiro; Uo, Motohiro; Takahashi, Hidekazu; Ueno, Toshiaki

    2016-01-01

    The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material.

  20. Accuracy of six elastic impression materials used for complete-arch fixed partial dentures.

    PubMed

    Stauffer, J P; Meyer, J M; Nally, J N

    1976-04-01

    1. The accuracy of four types of impression materials used to make a complete-arch fixed partial denture was evaluated by visual comparison and indirect measurement methods. 2. None of the tested materials allows safe finishing of a complete-arch fixed partial denture on a cast poured from one single master impression. 3. All of the tested materials can be used for impressions for a complete-arch fixed partial denture provided it is not finished on one single cast. Errors can be avoided by making a new impression with the fitted castings in place. Assembly and soldering should be done on the second cast. 4. In making the master fixed partial denture for this study, inaccurate soldering was a problem that was overcome with the use of epoxy glue. Hence, soldering seems to be a major source of inaccuracy for every fixed partial denture.

  1. Retention of denture bases fabricated by three different processing techniques – An in vivo study

    PubMed Central

    Chalapathi Kumar, V. H.; Surapaneni, Hemchand; Ravikiran, V.; Chandra, B. Sarat; Balusu, Srilatha; Reddy, V. Naveen

    2016-01-01

    Aim: Distortion due to Polymerization shrinkage compromises the retention. To evaluate the amount of retention of denture bases fabricated by conventional, anchorized, and injection molding polymerization techniques. Materials and Methods: Ten completely edentulous patients were selected, impressions were made, and master cast obtained was duplicated to fabricate denture bases by three polymerization techniques. Loop was attached to the finished denture bases to estimate the force required to dislodge them by retention apparatus. Readings were subjected to nonparametric Friedman two-way analysis of variance followed by Bonferroni correction methods and Wilcoxon matched-pairs signed-ranks test. Results: Denture bases fabricated by injection molding (3740 g), anchorized techniques (2913 g) recorded greater retention values than conventional technique (2468 g). Significant difference was seen between these techniques. Conclusions: Denture bases obtained by injection molding polymerization technique exhibited maximum retention, followed by anchorized technique, and least retention was seen in conventional molding technique. PMID:27382542

  2. Rechargeable Infection-responsive Antifungal Denture Materials

    PubMed Central

    Cao, Z.; Sun, X.; Yeh, C.-K.; Sun, Y.

    2010-01-01

    Candida-associated denture stomatitis (CADS) is a significant clinical concern. We developed rechargeable infection-responsive antifungal denture materials for potentially managing the disease. Polymethacrylic acid (PMAA) was covalently bound onto diurethane dimethacrylate denture resins in the curing step. The PMAA resins bound cationic antifungal drugs such as miconazole and chlorhexidine digluconate (CG) through ionic interactions. The anticandidal activities of the drug-containing PMAA-resin discs were sustained for a prolonged period of time (weeks and months). Drug release was much faster at acidic conditions (pH 5) than at pH 7. Drugs bound to the denture materials could be “washed out” by treatment with EDTA, and the drug-depleted resins could be recharged with the same or a different class of anticandidal drugs. These results suggest clinical potential of the newly developed antifungal denture materials in the management of CADS and other infectious conditions. PMID:20940361

  3. Removable partial denture on osseointegrated implants and natural teeth.

    PubMed

    Chang, Li-Ching; Wang, Jen-Chyan; Tasi, Chi-Cheng

    2007-01-01

    Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fitted with "removable partial dentures on implants and natural teeth". The patients were satisfied with their dentures in terms of function and aesthetics. Regular follow-up visits revealed that the periodontal and peri-implant conditions were stable. There was no evidence of excessive intrusion or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. Since the average duration of observation was about 38 months, further follow-up examinations are necessary to determine whether these dentures remain stable long-term.

  4. Prosthetic outcome, patient complaints, and nutritional effects on elderly patients with magnet-retained, implant-supported overdentures--a 1-year report.

    PubMed

    Khoo, Huan Ding; Chai, John; Chow, Tak Wah

    2013-01-01

    To study the changes in treatment outcomes of complete dentures and magnet-retained, implant-supported overdentures in a group of elderly patients. In this nonrandomized trial, 43 edentulous patients (14 men and 29 women) were fitted with complete dentures followed by implant-supported mandibular overdenture in a sequential model. Treatment outcomes used for analysis included objective assessment of denture quality (Woelfel's index), patient satisfaction, nutritional status, body mass index (BMI), and serum albumin level. The McNemar test was used to determine if significant differences in the Woelfel's index and nutritional status existed at different treatment phases. Repeated measures ANOVA and multiple pairwise comparison tests were used to analyze patient satisfaction. BMI status and serum albumin level at different treatment phases were analyzed with one-way ANOVA and Tukey post hoc test. At the 1-year follow-up, significant improvements were recorded for the objective assessment of denture quality and patient complaints (P < .05). No subject was found to be malnourished at pretreatment and in subsequent treatment phases. BMI and serum albumin level were not significantly different at different treatment phases (P > .05) CONCLUSIONS: The present study demonstrated that in elderly patients with stable health and nutritional status, complete dentures made in a university clinic brought about overall improvement in denture quality and reduction in denture complaint score. Insertion of mandibular implant-supported overdentures further improved the mandibular denture quality and reduced the mandibular denture complaint score. In this group of patients, no improvement in BMI, serum albumin value, and nutritional status were documented.

  5. Effects of different surface treatments on the bond strength of acrylic denture teeth to polymethylmethacrylate denture base material.

    PubMed

    Akin, Hakan; Kirmali, Omer; Tugut, Faik; Coskun, Mehmet Emre

    2014-09-01

    The purpose of this study was to investigate the effects of various surface pretreatments in the ridge lap area of acrylic resin denture teeth on the shear bond strength to heat-polymerized polymethylmethacrylate (PMMA) denture base resin. Tooth debonding of the denture is a major problem for patients with removable prostheses. A total of 84 central incisor denture teeth were used in this study. Seven test groups with 12 specimens for each group were prepared as follows: untreated (control, group C), ground, with a tungsten carbide bur (group H), airborne-particle abrasion (group AA), primed with methyl methacrylate (group M), treated with izobutyl methacrylate (group iBMA), Eclipse Bonding Agent applied (group E), and Er:YAG laser irradiated (group L). Test specimens were produced according to the manufacturers' instructions and mounted to a universal testing machine for shear testing with a crosshead speed of 1 mm/min. Data were evaluated by one way variance analysis (ANOVA) and Tukey's test (α=0.05). Similar bond strength values were found between groups L and M, and these were the highest shear bond strengths among the groups. The lowest one was observed in group E. All surface treatments, except group E, exhibited significant difference when compared with group C (p<0.05). Lasing of the ridge lap area to enhance the bond strength of acrylic resin denture teeth to PMMA denture base resin might be an alternative to wetting with MMA monomer. To overcome tooth debonding, surface treatment of the ridge lap area should be performed as part of denture fabrication.

  6. Denture adhesives: a systematic review.

    PubMed

    Papadiochou, Sofia; Emmanouil, Ioannis; Papadiochos, Ioannis

    2015-05-01

    Denture adhesives have been the objective of scientific research for over half a century. Although they are used by denture wearers worldwide, investigations of their effectiveness and biocompatibility have led to controversial conclusions. The purpose of this study was to review the literature data with regard to the effectiveness and biocompatibility of denture adhesives as well as the attitudes of both patients and dental professionals toward these materials. An electronic search of English peer-reviewed dental literature in the Medline database was conducted to evaluate the effectiveness and biocompatibility of denture adhesives. There was no limitation in publication year, so the search included all the available scientific evidence included in that particular database until March 2014. Specific inclusion criteria were used for the selection of the appropriate articles. A manual search of the citations of the obtained articles followed to extend the electronic search. A full text review was carried out for only 32 articles. Of the 32 articles, 21 examined the efficacy of denture adhesives in terms of retention and stability and masticatory performance, 6 evaluated the issue of the biocompatibility of denture adhesives, and 5 presented the attitudes of either professionals or patients toward these materials. The majority of clinical studies supported the fact that denture adhesives enhance the retention, stability, and masticatory performance of a removable prosthesis. In terms of biocompatibility, long-term in vivo studies to investigate potential harmful effects were lacking. Patients are satisfied with denture adhesives that meet their needs. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study.

    PubMed

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-06-01

    The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey's post-hoc test were used for statistical analysis. Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively.

  8. Expectations and final evaluation of complete dentures by patients, dentist and dental technician.

    PubMed

    Marachlioglou, C R M Z; Dos Santos, J F F; Cunha, V P P; Marchini, Leonardo

    2010-07-01

    There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207) and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

  9. A randomized clinical trial comparing the efficacy of mandibular implant-supported overdentures and conventional dentures in diabetic patients. Part V: food preference comparisons.

    PubMed

    Roumanas, Eleni D; Garrett, Neal R; Hamada, Michael O; Diener, Randy M; Kapur, Krishan K

    2002-01-01

    The functional benefits of replacing old dentures with new conventional mandibular dentures or implant-supported overdentures has not been fully determined. This study assessed the impact of these 2 types of replacement dentures on the food choices of diabetic patients. A total of 68 diabetic patients with original complete dentures participated in this study. Diabetes was controlled with insulin in 38 patients (IT) and without insulin in 30 patients (NIT). All subjects received conventional maxillary dentures; 25 received mandibular conventional dentures (CD), and 43 received overdentures with plastic clips and a Hader bar attached to 2 osseointegrated implants (IOD). Subjects rated their perceptions of taste acceptability, texture acceptability, and chewing ease on a 4-point nominal scale and eating frequency on a 5-point scale for 13 specific foods at baseline (with original dentures) and at 6 months post-treatment completion (PTC). Fisher exact tests were used to compare the change in percentage distributions of responses with treatment. A 2 x 2 x 2 repeated-measures analysis of variance (ANOVA) was performed to compare mean scores between the 2 denture groups, 2 diabetic groups, and 2 time intervals for each of the 13 foods and 4 questions related to food acceptability. At baseline, no significant differences were found between the frequency distributions of responses in the CD and IOD groups or the IT and NIT groups for all 52 comparisons. With both types of study dentures, a higher percentage of patients perceived deterioration rather than improvement in function. When percentage distributions based on actual positive or negative change (treatment effect) in patient responses were compared, significant differences were found for 3 of the 52 responses, in favor of the IOD group. ANOVA demonstrated significant mean differences for 4 of the 52 comparisons. Both types of study dentures resulted in declines in the perceived taste and texture acceptability of almost all test foods. Declines in perceived chewing ease and eating frequency were more common and greater in the CD than in the IOD group. Both types of study dentures failed to affect food choices, as evidenced by declines or limited improvement in the perceived frequency with which most foods were eaten.

  10. Cephalometric Evaluation of the Effect of Complete Dentures on Retropharyngeal Space and Its Effect on Spirometric Values in Altered Vertical Dimension

    PubMed Central

    Gupta, Prachi; Thombare, Ram; Pakhan, A. J.; Singhal, Sameer

    2011-01-01

    Role of complete dentures in reducing apnea-hypoapnea index in edentulous obstructive sleep apnea patient has shown promising results in previous studies. This study was undertaken to ascertain the role of complete denture and complete denture with slight increase in vertical dimension using custom made occlussal jig, on retropharyngeal space, posterior airway space, pharyngeal depth, and spirometric readings in comparison with those in edentulous group. Significant changes were observed in both intervention groups and thus, paving the way for doing further research for the consideration of using complete denture with modifications as an oral appliance in edentulous obstructive sleep apnea patient. PMID:21991477

  11. Factors affecting the distribution and prevalence of oral mucosal lesions in complete denture wearers.

    PubMed

    Mandali, Gamze; Sener, Işıl Damla; Turker, Sebnem Begum; Ulgen, Hasan

    2011-06-01

    To determine the frequency of the oral lesions related to gender, age, the length of time of denture usage, education level and economic status. The 153 patients with old complete dentures (CD) were asked to participate in the investigation. The subjects (76 male and 77 female) were 37-85 years of age with a mean age of 61.8 ± 9.8 years. Education, economic status and age factors were estimated in subgroups. The data obtained were evaluated by one-way anova, Mann-Whitney U-test, Kruskal-Wallis test, Student's t-test and chi-squared test. The level of statistical significance was set at p<0.05. The patients who had denture stomatitis and traumatic ulcers were statistically significantly older than the ones who did not have these lesions (p<0.05). Based on the length of denture usage, patients who had a flabby ridge, fibrous inflammatory hyperplasia, traumatic ulcers (p<0.01) and denture stomatitis (p<0.05) were using their dentures statistically significantly longer than the ones who had healthy tissues. The CD wearers should be advised to visit their dentist regularly to prevent oral mucosal lesions due to the changing supporting tissues during the length of denture usage and to improve their quality of life. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  12. Effect of biofilm formation, and biocorrosion on denture base fractures.

    PubMed

    Sahin, Cem; Ergin, Alper; Ayyildiz, Simel; Cosgun, Erdal; Uzun, Gulay

    2013-05-01

    The aim of this study was to investigate the destructive effects of biofilm formation and/or biocorrosive activity of 6 different oral microorganisms. Three different heat polymerized acrylic resins (Ivocap Plus, Lucitone 550, QC 20) were used to prepare three different types of samples. Type "A" samples with "V" type notch was used to measure the fracture strength, "B" type to evaluate the surfaces with scanning electron microscopy and "C" type for quantitative biofilm assay. Development and calculation of biofilm covered surfaces on denture base materials were accomplished by SEM and quantitative biofilm assay. According to normality assumptions ANOVA or Kruskal-Wallis was selected for statistical analysis (α=0.05). Significant differences were obtained among the adhesion potential of 6 different microorganisms and there were significant differences among their adhesion onto 3 different denture base materials. Compared to the control groups after contamination with the microorganisms, the three point bending test values of denture base materials decreased significantly (P<.05); microorganisms diffused at least 52% of the denture base surface. The highest median quantitative biofilm value within all the denture base materials was obtained with P. aeruginosa on Lucitone 550. The type of denture base material did not alter the diffusion potential of the microorganisms significantly (P>.05). All the tested microorganisms had destructive effect over the structure and composition of the denture base materials.

  13. Effect of biofilm formation, and biocorrosion on denture base fractures

    PubMed Central

    Ergin, Alper; Ayyildiz, Simel; Cosgun, Erdal; Uzun, Gulay

    2013-01-01

    PURPOSE The aim of this study was to investigate the destructive effects of biofilm formation and/or biocorrosive activity of 6 different oral microorganisms. MATERIALS AND METHODS Three different heat polymerized acrylic resins (Ivocap Plus, Lucitone 550, QC 20) were used to prepare three different types of samples. Type "A" samples with "V" type notch was used to measure the fracture strength, "B" type to evaluate the surfaces with scanning electron microscopy and "C" type for quantitative biofilm assay. Development and calculation of biofilm covered surfaces on denture base materials were accomplished by SEM and quantitative biofilm assay. According to normality assumptions ANOVA or Kruskal-Wallis was selected for statistical analysis (α=0.05). RESULTS Significant differences were obtained among the adhesion potential of 6 different microorganisms and there were significant differences among their adhesion onto 3 different denture base materials. Compared to the control groups after contamination with the microorganisms, the three point bending test values of denture base materials decreased significantly (P<.05); microorganisms diffused at least 52% of the denture base surface. The highest median quantitative biofilm value within all the denture base materials was obtained with P. aeruginosa on Lucitone 550. The type of denture base material did not alter the diffusion potential of the microorganisms significantly (P>.05). CONCLUSION All the tested microorganisms had destructive effect over the structure and composition of the denture base materials. PMID:23755339

  14. Microwave disinfection of maxillary and mandibular denture bases contaminated with Candida Albican.

    PubMed

    Bamigboye, S A; Dosumu, O O; Ajayi, D M

    2015-09-01

    Oral environment is not sterile, and dentures worn by the patients can be infected and therefore needs disinfection. Solution disinfectants such as sodium hypochlorite and glutaraldehyde can be used but they have side effects. Microwave disinfection method is more recent, however, there are conflicting reports at the moment on the appropriate power and time regimen for disinfection of denture. To determine the power and time regimen at which the disinfection of dentures can be achieved using microwave. Forty-five acrylic denture bases were fabricated for each of the jaws and infected with solution of a stock Candida albicans and 30 infected bases were employed as control. These were placed in normal saline and then subjected to different microwave power and time regimen. Aliquots from these post-microwave solution were titrated against sabauraud agar which was subsequently incubated at 37 degrees C for 48 hours. The agar were examined for candida growth. The denture bases subjected to microwave disinfection at 350W showed Candida growth after microwave treatment irrespective of the time employed. Conversely, those microwaved at 650W and 690W for four and six minutes showed no microbial growth. The microwave regimen of 650W at 4 and 6 minutes completely disinfected the denture bases. Disinfection at higher microwave energy should be done with caution as distortion of the denture may occur.

  15. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  16. Effect of surface treatments on shear bond strength of denture teeth to denture base resins

    PubMed Central

    Bahrani, Farideh; Khaledi, Amir Ali Reza

    2014-01-01

    Background: Debonding of denture teeth from denture bases is the most common failure in removable dentures. The purpose of this study was to evaluate the effect of surface treatments on shear bond strength of denture teeth to heat-polymerized and autopolymerized denture base resins. Materials and Methods: In this experimental in vitro study, 60 maxillary central incisor acrylic teeth were divided into two groups. Group M was polymerized with heat-polymerized acrylic resin (Meliodent) by compression molding technique and group F was processed by autopolymerized acrylic resin (Futura Gen) by injection molding technique. Within each group, specimens were divided into three subgroups according to the teeth surface treatments (n = 10): (1) ground surface as the control group (M1 and F1), (2) ground surface combined with monomer application (M2 and F2), and (3) airborne particle abrasion by 50 μm Al2O3 (M3 and F3). The shear bond strengths of the specimens were tested by universal testing machine with crosshead speed of 5 mm/min. Data were analyzed by two-way analysis of variance (ANOVA) and Tukey's honestly significant difference (HSD) tests (P < 0.05). Results: The mean shear bond strengths of the studied groups were 96.40 ± 14.01, 124.70 ± 15.64, and 118 ± 16.38 N for M1, M2, and M3 and 87.90 ± 13.48, 117 ± 13.88, and 109.70 ± 13.78 N for F1, F2, and F3, respectively. The surface treatment of the denture teeth significantly affected their shear bond strengths to the both the denture base resins (P < 0.001). However, there were no significant differences between the groups treated by monomer or airborne particle abrasion (P = 0.29). The highest percentage of failure mode was mixed in Meliodent and adhesive in Futura Gen. Conclusion: Monomer application and airborne particle abrasion of the ridge lap area of the denture teeth improved their shear bond strengths to the denture base resins regardless of the type of polymerization. PMID:24688570

  17. Effect of complete dentures on dynamic measurement of changing head position: A pilot study.

    PubMed

    Usumez, Aslihan; Usumez, Serdar; Orhan, Metin

    2003-10-01

    Complete dentures contribute significantly to the facial esthetics of edentulous patients. However, information as to the effect of complete dentures on the natural position of the head is limited. The purpose of this pilot study was to evaluate the immediate and 30-day effect of wearing complete dentures on the dynamic natural head position measured during walking. The sample consisted of a volunteer group of 16 patients, 8 women and 8 men, who received new complete dentures. The ages of the subjects ranged from 45 to 64 years (mean=52 years). Dynamic measurement of head posture was carried out by a specially constructed inclinometer device. Each subject in turn was fitted with the inclinometer system and instructed to walk in a relaxed manner for 5 minutes. The data, measured as degrees, were stored in a pocket data logger. This procedure was repeated before insertion of dentures (T1), immediately after insertion of dentures (T2), and 30 days after insertion of dentures (T3). Stored dynamic head posture data were transferred to computer for analysis. The means of the measurements were statistically compared with Friedman and following Wilcoxon tests (alpha =.05). Twelve of 16 (75%) subjects showed an average of 4.6 degrees of cranial extension immediately after insertion of dentures. Six (37.5%) subjects showed an average of 6.4 degrees of cranial flexion, and 8 (50%) subjects showed an average of 5.2 degrees of cranial extension at T3 relative to the T1 measurement. Dynamic head posture measurements of the other 2 subjects remained unchanged. There were significant differences between different measurements of dynamic head posture positions (P<.025). However, only the T1 and T2 measurements were significantly different (P<.015). The findings indicate that the statistically significant average extension 4.6 degrees in subjects immediately after insertion of complete dentures was not stable after a 30-day evaluation period and did not produce any statistically significant change. The overall effect of wearing dentures was an irregular flexion or extension pattern on dynamic head posture.

  18. Relationship between oral Candida species and risk factors with reference to drugs with xerostomic side effects among institutionalised elderly in Aichi Pref., Japan.

    PubMed

    Yamanaka, Katsumi; Nakagaki, Haruo; Morita, Ichizo; Maeda, Nobuko; Ohara, Hisakazu; Tomatsu, Shinpei; Nakashima, Toshiro; Watanabe, Yosinori; Ohta, Noriaki; Shibata, Kyoko

    2005-03-01

    To clarify the relationship between Candida carriage and drugs which have reported xerostomic side effects in the elderly. Cross-sectional study. Setting Two long-term care facilities in Aichi Pref., Japan. Eight men and 63 women with a mean age of 86 years (range 62 to 95 years) with at least some of their natural teeth. Oral examination by dentists, microbiological test by microbiologists, questionnaire interviews, and data obtained from medical files. The Candida species (CFU) was adopted as an objective variable with risk indicators being age, number of teeth, saliva flow rate, denture wearing, xerostomic drugs, activities of daily living (ADL), frequency of brushing and type of meals. Bivariate analysis confirmed that participants with a higher number of Candida species (CFU) fell into the following categories: denture wearing (p < 0.05), older age (p < 0.05), xerostomic drugs (p < 0.10), more teeth, poor ADL, soft/liquid meals, and brushing once a day. This was in contrast to the categories of no denture wearing, younger age, no xerostomic drugs, fewer teeth, good ADL, normal meals, and brushing two or more times a day, in that order of significant probability on an ascending scale. A multiple logistics regression model confirmed that the variables of older age (80 years and over) and more teeth (six or more) had statistically significant (p < 0.05) effects on the number of Candida species present (CFU). Xerostomic drugs and the other variables had no significant effect. Older age and more teeth had a significant effect on the number of oral Candida species in the elderly. The results of this study did not support a role of those drugs as a risk indicator for oral Candida carriage. Larger trials are needed to assess the effect of drugs on the presence of oral Candida.

  19. IN VITRO WEAR RESISTANCE OF THREE TYPES OF POLYMETHYL METHACRYLATE DENTURE TEETH

    PubMed Central

    Reis, Katia Rodrigues; Bonfante, Gerson; Pegoraro, Luiz Fernando; Conti, Paulo Cesar Rodrigues; de Oliveira, Pedro Cesar Garcia; Kaizer, Osvaldo Bazzan

    2008-01-01

    The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (α=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth. PMID:19089214

  20. Improvised Neutral Zone Technique in a Completely Edentulous Patient with an Atrophic Mandibular Ridge and Neuromuscular Incoordination: A Clinical Tip

    PubMed Central

    Thirumalai Thangarajan, Saravanan; Mani, Umamaheswari; Kumar V, Anand

    2017-01-01

    Resorption of mandibular ridges is a multifactorial and biomechanical disease that is chronic, progressive, irreversible, and cumulative leading to loss of sulcular depth, vertical dimension loss, and decreased lower facial height. Some common neurological, hormonal, and metabolic disorders affect the adaptability of dentures, and this can be diagnosed by a trained prosthodontist with proper history-taking and clinical examination.The denture becomes passive due to complex neuromuscular control and causes difficulties in impression-making, mastication, and swallowing, which in turn leads to loss of retention and stability in complete dentures. Hence, residual ridge resorption becomes a challenging scenario for a clinician during fabrication of complete dentures. The neutral zone concept plays a significant role in overcoming these challenges. The neutral zone is the area where the outward forces from the tongue are neutralized or nullified by the forces of the lips and cheeks acting inward during functional movements.The neutral zone technique is an alternative approach for the construction of lower complete dentures. It is most effective for dentures where there is a highly atrophic ridge and history of denture instability. The technique aims to construct a denture that is shaped by muscle function and is in harmony with the surrounding oral structures. The technique is by no means new, but it is a valuable one. It is rarely used because of the extra clinical step involved and its complexity. Complete and partial denture failures are often related to non-compliance with neutral zone factors. Thus, the evaluation of the neutral zone is an important factor. Increased retention and stability with reduced chairside time are the salient features of this new approach to any clinically challenging situation in complete dentures.This clinical report describes a modification of the conventional neutral zone technique using improvised procedures to minimize chairside visits for a patient with an atrophic mandibular ridge and neuromuscular incoordination. PMID:28553567

  1. Efficacy of citric acid denture cleanser on the Candida albicans biofilm formed on poly(methyl methacrylate): effects on residual biofilm and recolonization process.

    PubMed

    Faot, Fernanda; Cavalcanti, Yuri Wanderley; Mendonça e Bertolini, Martinna de; Pinto, Luciana de Rezende; da Silva, Wander José; Cury, Altair Antoninha Del Bel

    2014-06-23

    It is well known that the use of denture cleansers can reduce Candida albicans biofilm accumulation; however, the efficacy of citric acid denture cleansers is uncertain. In addition, the long-term efficacy of this denture cleanser is not well established, and their effect on residual biofilms is unknown. This in vitro study evaluated the efficacy of citric acid denture cleanser treatment on C. albicans biofilm recolonization on poly(methyl methacrylate) (PMMA) surface. C. albicans biofilms were developed for 72 h on PMMA resin specimens (n = 168), which were randomly assigned to 1 of 3 cleansing treatments (CTs) overnight (8 h). CTs included purified water as a control (CTC) and two experimental groups that used either a 1:5 dilution of citric acid denture cleanser (CT5) or a 1:8 dilution of citric acid denture cleanser (CT8). Residual biofilms adhering to the specimens were collected and quantified at two time points: immediately after CTs (ICT) and after cleaning and residual biofilm recolonization (RT). Residual biofilms were analyzed by quantifying the viable cells (CFU/mL), and biofilm architecture was evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Denture cleanser treatments and evaluation periods were considered study factors. Data were analyzed using two-way ANOVA and Tukey's Honestly Significant Difference (HSD) test (α = 0.05). Immediately after treatments, citric acid denture cleansing solutions (CT5 and CT8) reduced the number of viable cells as compared with the control (p < 0.01). However, after 48 h, both CT groups (CT5 and CT8) showed biofilm recolonization (p < 0.01). Residual biofilm recolonization was also detected by CLSM and SEM analysis, which revealed a higher biomass and average biofilm thickness for the CT8 group (p < 0.01). Citric acid denture cleansers can reduce C. albicans biofilm accumulation and cell viability. However, this CT did not prevent biofilm recolonization.

  2. Improvised Neutral Zone Technique in a Completely Edentulous Patient with an Atrophic Mandibular Ridge and Neuromuscular Incoordination: A Clinical Tip.

    PubMed

    Saravanakumar, Prathibha; Thirumalai Thangarajan, Saravanan; Mani, Umamaheswari; Kumar V, Anand

    2017-04-24

    Resorption of mandibular ridges is a multifactorial and biomechanical disease that is chronic, progressive, irreversible, and cumulative leading to loss of sulcular depth, vertical dimension loss, and decreased lower facial height. Some common neurological, hormonal, and metabolic disorders affect the adaptability of dentures, and this can be diagnosed by a trained prosthodontist with proper history-taking and clinical examination.The denture becomes passive due to complex neuromuscular control and causes difficulties in impression-making, mastication, and swallowing, which in turn leads to loss of retention and stability in complete dentures. Hence, residual ridge resorption becomes a challenging scenario for a clinician during fabrication of complete dentures. The neutral zone concept plays a significant role in overcoming these challenges. The neutral zone is the area where the outward forces from the tongue are neutralized or nullified by the forces of the lips and cheeks acting inward during functional movements.The neutral zone technique is an alternative approach for the construction of lower complete dentures. It is most effective for dentures where there is a highly atrophic ridge and history of denture instability. The technique aims to construct a denture that is shaped by muscle function and is in harmony with the surrounding oral structures. The technique is by no means new, but it is a valuable one. It is rarely used because of the extra clinical step involved and its complexity. Complete and partial denture failures are often related to non-compliance with neutral zone factors. Thus, the evaluation of the neutral zone is an important factor. Increased retention and stability with reduced chairside time are the salient features of this new approach to any clinically challenging situation in complete dentures.This clinical report describes a modification of the conventional neutral zone technique using improvised procedures to minimize chairside visits for a patient with an atrophic mandibular ridge and neuromuscular incoordination.

  3. Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

    PubMed

    Kumar, Lalit; Sehgal, Komal

    2014-06-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

  4. Development of chair-side evaluation system of swallowing discomfort of denture wearers

    NASA Astrophysics Data System (ADS)

    Matsumoto, Keisuke; Ikuta, Ryuhei; Kataoka, Kanako; Ono, Yumie; Tamaki, Katsushi

    2018-02-01

    We investigated the appropriate hemodynamic parameters of functional near-infrared spectroscopy (fNIRS) to best differentiate the discomfort intensity related to swallowing in healthy subjects wearing different types of simulated dentures. Thirty-one subjects performed 4 sessions of water-swallowing task in a sitting position without or with wearing any one of the 3 simulated dentures under continuous fNIRS monitoring of the prefrontal cortex. The simulated dentures were consisted of a flat maxillary palatal bar and bilateral support attachment to the teeth and gum. The palatal bar positions were arranged along with the anterior, middle, or posterior areas of the upper jaw. The cumulative values of oxyhemoglobin and deoxyhemoglobin concentration changes were calculated for periods of 5 - 10 s from completion of swallowing. Subjective rating of swallowing-discomfort was the lowest without wearing denture and increased along with the palatal bar position placed from anterior to posterior. Cumulated deoxyhemoglobin signals calculated for 10 s post-swallowing event in the left frontopolar prefrontal cortex showed the best correlation with the subjective rating of discomfort in swallowing with dentures. These neurological signatures would be beneficial to detect swallowing discomfort in elderly denture wearers who have difficulty in communicating with dentists.

  5. Influence of Prosthetic Screw Material on Joint Stability in Passive and Non-Passive Implant-Supported Dentures

    PubMed Central

    Spazzin, Aloísio Oro; Henriques, Guilherme Elias Pessanha; de Arruda Nóbilo, Mauro Antônio; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço; Mesquita, Marcelo Ferraz

    2009-01-01

    Objectives: This study evaluated the influence of prosthetic screw material on joint stability in implantsupported dentures at two levels of fit. Methods: Ten mandibular implant-supported dentures were fabricated. Twenty cast models were fabricated using these dentures. Four groups (n=10) were tested, according to the vertical fit of the dentures [passive and non-passive] and prosthetic screw materials [titanium (Ti) or gold (Au) alloy]. The one-screw test was performed to quantify the vertical misfits using an optic microscope. The loosening torque for the prosthetic screws was measured 24 hours after the tightening torque (10 Ncm) using a digital torque meter. Data were analyzed by two-way ANOVA and Tukey’s test (α=0.05). Results: Overall, dentures with passive fit and Ti screws resulted in significantly higher loosening torque of the prosthetic screws (p<0.05). No significant interaction was found between fit level and screw material (p=0.199). The prosthetic screw material and fit of implant-supported dentures have an influence on screw joint stability. Ti screws presented higher joint stability than Au screws and minimum of misfit should be found clinically to improve the mechanical behavior of the screw joint. PMID:20148135

  6. Two implants for all edentulous mandibles.

    PubMed

    Wright, P S

    2006-04-22

    Complete dentures have always been a poor substitute for natural teeth. Mandibular complete dentures frequently cause pain and discomfort, accelerated residual bone resorption, while failing to restore effective chewing. The provision of two implants to stabilise the mandibular complete denture can result in significant improvements.

  7. The value of dentures.

    PubMed

    Levin, Roger P

    2003-05-01

    Dentures may be boring, but they are a major part of dentistry, and will be for the foreseeable future. While implants are growing in popularity, there will always be patients who opt for dentures. It is your duty to inform patients of the need to have their dentures remade periodically, to ensure excellent oral care. Be sure to manage patient expectation and to create an effective system for prompt payment. This will enable you to help patients achieve good oral health, while maximizing your profit.

  8. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA.

    PubMed

    Qamheya, Ala Hassan A; Yeniyol, Sinem; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient.

  9. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA

    PubMed Central

    Qamheya, Ala Hassan A.; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient. PMID:26557392

  10. [Computer aided design for fixed partial denture framework based on reverse engineering technology].

    PubMed

    Sun, Yu-chun; Lü, Pei-jun; Wang, Yong

    2006-03-01

    To explore a computer aided design (CAD) route for the framework of domestic fixed partial denture (FPD) and confirm the suitable method of 3-D CAD. The working area of a dentition model was scanned with a 3-D mechanical scanner. Using the reverse engineering (RE) software, margin and border curves were extracted and several reference curves were created to ensure the dimension and location of pontic framework that was taken from the standard database. The shoulder parts of the retainers were created after axial surfaces constructed. The connecting areas, axial line and curving surface of the framework connector were finally created. The framework of a three-unit FPD was designed with RE technology, which showed smooth surfaces and continuous contours. The design route is practical. The result of this study is significant in theory and practice, which will provide a reference for establishing the computer aided design/computer aided manufacture (CAD/CAM) system of domestic FPD.

  11. Antifungal Effect of Henna against Candida albicans Adhered to Acrylic Resin as a Possible Method for Prevention of Denture Stomatitis

    PubMed Central

    Nawasrah, Amal; AlNimr, Amani; Ali, Aiman A.

    2016-01-01

    Denture stomatitis is a very common disease affecting the oral mucosa of denture wearers. The aim of this study was to measure the antifungal effect of henna against Candida albicans adhered to acrylic resin as a possible method for prevention of denture stomatitis. One-hundred-eighty acrylic plates were prepared of heat-cured acrylic denture resin. The specimens were divided into six groups of 30 samples each. The first group was only polymer and monomer following the conventional manufacturer instruction for processing complete dentures. The other five groups were processed by adding different concentration of Yamani henna powder (Harazi) to the polymer in a concentration of henna: polymer 1%, 2.5%, 5%, 7.5% and 10%, respectively. Samples were incubated in artificial saliva rich with Candida albicans at 37 °C, and the effect of henna on Candida albicans was evaluated in two different methods: semi-quantitative slide count and a culture-based quantitative assay (quantitative). Variation in the number of live Candida was observed with the increase in the concentration of Yamani henna powder. It was observed that the variation in live Candida, between control group and group B (concentration of Yamani henna powder was 1%), was statistically significant with a p-value of 0.0001. Similarly, variations in live Candida were significant, when the concentration of powder was 7.5% or 10% in contrast with control group and p-values were 0.0001 and 0.001 respectively. Adding henna to acrylic resin denture could be effective in controlling Candida albicans proliferation on the denture surface; however, its effects on the physical properties of acrylic resin denture need further studies. PMID:27223294

  12. Evaluation of the influence of blood glucose level on oral candidal colonization in complete denture wearers with Type-II Diabetes Mellitus: An in vivo Study.

    PubMed

    Ganapathy, Dhanraj Muthuveera; Joseph, Sajeesh; Ariga, Padma; Selvaraj, Anand

    2013-01-01

    Candidal colonization in complete denture wearers is a commonly encountered condition that worsens in the presence of untreated Diabetes Mellitus. The aim of this study was to evaluate the correlation between oral candidiasis in denture-bearing mucosa and elevated blood glucose levels in complete denture wearers and to evaluate the effect of oral hypoglycemic drug therapy in controlling oral candidal colonization in denture-bearing mucosa of complete denture wearers with Type II Diabetes Mellitus. This prospective observational study involved the participation of 15 complete denture wearers with Type II Diabetes Mellitus. The sample collection was made prior and after oral hypoglycaemic drug intervention, by swabbing the rugal surfaces of palatal mucosa, cultured and the density of the candidal colony formed was analyzed and interpreted as colony forming units (CFU) per mL. The candidal samples CFU and corresponding pre- and post-prandial blood glucose levels were estimated, analyzed and compared using Karl Pearson correlation analysis and paired t-test (α = 0.05). The Karl Pearson correlation analysis showed that there was a positive correlation between the blood glucose levels (PPS and FBS) and the candidal colonization (CFU) (P < 0.05). The mean values of all the variables were analyzed using the paired t-test. There was significant reduction in the mean values of blood glucose levels (P < 0.001) and the mean values of the CFU (P < 0.001) following oral hypoglycemic drug therapy. Positive correlation was observed between oral candidiasis in complete denture-bearing mucosa and elevated blood glucose levels and oral hypoglycemic drug therapy has a positive effect in controlling oral candidal colonization in complete denture wearers with Type II Diabetes Mellitus.

  13. The impact of the National Denture Service on oral health-related quality of life among poor elders.

    PubMed

    Ha, J E; Heo, Y J; Jin, B H; Paik, D I; Bae, K H

    2012-08-01

    The objective of this study was to assess the effects of the Korean National Denture Service (NDS) for poor elderly people requiring dentures on oral health-related quality of life (OHRQOL). Data from follow-up studies were collected from 439 subjects at eight public health centres who answered every question of a questionnaire, and the OHRQOL was measured at the baseline and at 3-month follow-up after receiving the NDS according to the type of denture provision. The multivariate linear mixed model with a public health centre as a random effect for the score change of Oral Health Impact Profile (OHIP)-14K was carried out to confirm the factors related to the improvement in OHRQOL. The mean OHIP-14K was 28.60 at the baseline time points, and there was a decrease in the OHIP-14 scores to 21.14 ± 12.52 at the 3-month follow-up of the removable partial denture beneficiaries. The changes in OHIP-14K among complete denture beneficiaries were 21.53 ± 12.01 for previously dentate subjects and 22.54 ± 11.12 for edentate subjects. The multivariate linear mixed model of dentate subjects demonstrated that the improvement in the OHRQOL was associated with the number of remaining teeth, satisfaction with denture and self-reported oral health status after 3 months. In the case of the edentate model, satisfaction with denture was the only factor related to the improvement in OHRQOL. This study revealed considerable improvement in OHRQOL among poor elderly people after NDS. Satisfaction with provision of dentures was associated with improvement in the OHRQOL. © 2012 Blackwell Publishing Ltd.

  14. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study

    PubMed Central

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-01-01

    Background: The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. Materials and Methods: The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey’s post-hoc test were used for statistical analysis. Results: Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Conclusions: Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively. PMID:26124604

  15. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

    PubMed

    Babu, Sumanth; Manjunath, Shaurya; Vajawat, Mayuri

    2016-01-01

    The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA), which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05) and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05) movement in buccal direction during all stages of denture processing. Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  16. Social determinants of denture/bridge use: Japan gerontological evaluation study project cross-sectional study in older Japanese.

    PubMed

    Yamamoto, Tatsuo; Kondo, Katsunori; Aida, Jun; Suzuki, Kayo; Misawa, Jimpei; Nakade, Miyo; Fuchida, Shinya; Hirata, Yukio

    2014-06-03

    Studies suggest that using a denture/bridge may prevent disability in older people. However, not all older people with few remaining teeth use a denture/bridge. This cross-sectional study aimed to examine the social determinants which promote denture/bridge use among older Japanese. A total of 54,388 (25,630 males and 28,758 females) community-dwelling individuals aged 65 or over, living independently, able to perform daily activities, and with 19 or fewer teeth. The dependent variable was denture/bridge use. Socio-demographics, number of teeth, present illness, social participation, social support, and social networks were used as individual-level independent variables. Data for social capital were aggregated and used as local district (n = 561 for males, n = 562 for females) -level independent variables. Number of dentists working in hospitals/clinics per population and population density were used as municipality (n = 28) -level independent variables. Three-level multilevel Poisson regression analysis was performed for each sex. High equivalent income, low number of teeth, present illness, and living in a municipality with high population density were significantly associated with denture/bridge use in both sexes in the fully adjusted models (p < 0.05). Denture/bridge use was significantly associated with high educational attainment in males and participating in social groups in females in the fully adjusted model (p < 0.05). No significant associations were observed between denture/bridge use and social capital. Denture/bridge use was significantly associated with high economic status and present illness in both sexes, high educational attainment in males, and participation in social groups in females among community-dwelling older Japanese after adjusting for possible confounders.

  17. Microscope self-calibration based on micro laser line imaging and soft computing algorithms

    NASA Astrophysics Data System (ADS)

    Apolinar Muñoz Rodríguez, J.

    2018-06-01

    A technique to perform microscope self-calibration via micro laser line and soft computing algorithms is presented. In this technique, the microscope vision parameters are computed by means of soft computing algorithms based on laser line projection. To implement the self-calibration, a microscope vision system is constructed by means of a CCD camera and a 38 μm laser line. From this arrangement, the microscope vision parameters are represented via Bezier approximation networks, which are accomplished through the laser line position. In this procedure, a genetic algorithm determines the microscope vision parameters by means of laser line imaging. Also, the approximation networks compute the three-dimensional vision by means of the laser line position. Additionally, the soft computing algorithms re-calibrate the vision parameters when the microscope vision system is modified during the vision task. The proposed self-calibration improves accuracy of the traditional microscope calibration, which is accomplished via external references to the microscope system. The capability of the self-calibration based on soft computing algorithms is determined by means of the calibration accuracy and the micro-scale measurement error. This contribution is corroborated by an evaluation based on the accuracy of the traditional microscope calibration.

  18. Allergic effects of the residual monomer used in denture base acrylic resins

    PubMed Central

    Rashid, Haroon; Sheikh, Zeeshan; Vohra, Fahim

    2015-01-01

    Denture base resins are extensively used in dentistry for a variety of purposes. These materials can be classified as chemical, heat, light, and microwave polymerization materials depending upon the factor which starts the polymerization reaction. Their applications include use during denture base construction, relining existing dentures, and for fabrication of orthodontic removable appliances. There have been increased concerns regarding the safe clinical application of these materials as their biodegradation in the oral environment leads to harmful effects. Along with local side effects, the materials have certain occupational hazards, and numerous studies can be found in the literature mentioning those. The purpose of this article is to outline the cytotoxic consequences of denture base acrylic resins and clinical recommendations for their use. PMID:26929705

  19. Influence of chemical and mechanical polishing on water sorption and solubility of denture base acrylic resins.

    PubMed

    Rahal, Juliana Saab; Mesquita, Marcelo Ferraz; Henriques, Guilherme Elias Pessanha; Nóbilo, Mauro Antonio Arruda

    2004-01-01

    Influence of polishing methods on water sorption and solubility of denture base acrylic resins was studied. Eighty samples were divided into groups: Classico (CL), and QC 20 (QC) - hot water bath cured; Acron MC (AC), and Onda Cryl (ON) - microwave cured; and submitted to mechanical polishing (MP) - pumice slurry, chalk powder, soft brush and felt cone in a bench vise; or chemical polishing (CP) - heated monomer fluid in a chemical polisher. The first desiccation process was followed by storage in distilled water at 37 +/- 1 degrees C for 1 h, 1 day, 1, 2, 3 and 4 weeks. Concluding each period, water sorption was measured. After the fourth week, a second desiccation process was done to calculate solubility. Data were submitted to analysis of variance, followed by Tukey test (p

  20. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing.

    PubMed

    Zhang, Yong-de; Jiang, Jin-gang; Liang, Ting; Hu, Wei-ping

    2011-12-01

    Artificial teeth are very complicated in shape, and not easy to be grasped and manipulated accurately by a single robot. The method of tooth-arrangement by multi-manipulator for complete denture manufacturing proposed in this paper. A novel complete denture manufacturing mechanism is designed based on multi-manipulator and dental arch generator. Kinematics model of the multi-manipulator tooth-arrangement robot is built by analytical method based on tooth-arrangement principle for full denture. Preliminary experiments on tooth-arrangement are performed using the multi-manipulator tooth-arrangement robot prototype system. The multi-manipulator tooth-arrangement robot prototype system can automatically design and manufacture a set of complete denture that is suitable for a patient according to the jaw arch parameters. The experimental results verified the validity of kinematics model of the multi-manipulator tooth-arrangement robot and the feasibility of the manufacture strategy of complete denture fulfilled by multi-manipulator tooth-arrangement robot.

  1. Application of addition-cured silicone denture relining materials to adjust mouthguards.

    PubMed

    Fukasawa, Shintaro; Churei, Hiroshi; Chowdhury, Ruman Uddin; Shirako, Takahiro; Shahrin, Sharika; Shrestha, Abhishekhi; Wada, Takahiro; Uo, Motohiro; Takahashi, Hidekazu; Ueno, Toshiaki

    2016-01-01

    The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials and eleven commercial mouthguard materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material.

  2. Evaluation of chitosan quaternary ammonium salt-modified resin denture base material.

    PubMed

    Song, Rong; Zhong, Zhaohua; Lin, Lexun

    2016-04-01

    Chitosan quaternary ammonium salt displays good antioxidant and antibacterial characteristics and it shows appreciable solubility in water. When added to the traditional denture material to form a resin base, it could promote good oral health by improving the oral environment. In this study, chitosan quaternary ammonium salt was added to the denture material following two different methods. After three months of immersion in artificial saliva, the specimens were tested for tensile strength and were scanned by electron microscope. The murine fibroblast cytotoxicity and antibacterial properties were also tested. The result showed no significant differences in the tensile strength and in the proliferation of murine L929 fibroblast cells. The two structures of chitosan quaternary ammonium salt-modified denture material had different degrees of corrosion resistance and antimicrobial properties. These results indicate that chitosan quaternary ammonium salt-modified resin denture base material has the potential to become a new generation oral denture composite material. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data.

    PubMed

    Goodacre, Charles J; Garbacea, Antoanela; Naylor, W Patrick; Daher, Tony; Marchack, Christopher B; Lowry, Jean

    2012-01-01

    The clinical impression procedures described in this article provide a method of recording the morphology of the intaglio and cameo surfaces of complete denture bases and also identify muscular and phonetic locations for the prosthetic teeth. When the CAD/CAM technology for fabricating complete dentures becomes commercially available, it will be possible to scan the denture base morphology and tooth positions recorded with this technique and import those data into a virtual tooth arrangement program where teeth can be articulated and then export the data to a milling device for the fabrication of the complete dentures. A prototype 3-D tooth arrangement program is described in this article that serves as an example of the type of program than can be used to arrange prosthetic teeth virtually as part of the overall CAD/CAM fabrication of complete dentures. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  4. Treatment planning: implant-supported partial overdentures.

    PubMed

    Chee, Winston W L

    2005-04-01

    When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the implant-supported overdenture has several advantages, some in common with a removable partial denture.

  5. An Investigation into the Trueness and Precision of Copy Denture Templates Produced by Rapid Prototyping and Conventional Means.

    PubMed

    Davda, K; Osnes, C; Dillon, S; Wu, J; Hyde, P; Keeling, A

    2017-12-01

    To assess the trueness and precision of copy denture templates produced using traditional methods and 3D printing. Six copies of a denture were made using: 1. Conventional technique with silicone putty in an impression tray (CT). 2. Conventional technique with no impression tray (CNT). 3. 3D scanning and printing (3D). Scan trueness and precision was investigated by scanning a denture six times and comparing five scans to the sixth. Then the scans of the six CT, CNT and 3D dentures were compared by aligning, in turn, the copies of each denture to the scanned original. Outcome measures were the mean surface-to-surface distance, standard deviation of that distance and the maximum distance. Student's unpaired t-tests with Bonferroni correction were used to analyse the results. The repeated scans of the original denture showed a scan trueness of 0.013mm (SD 0.002) and precision of 0.013mm (SD 0.002). Trueness: CT templates, 0.168mm (0.047), CNT templates 0.195mm (0.034) and 3D 0.103mm (0.021). Precision: CT templates 0.158mm (0.037), CNT 0.233mm (0.073), 3D 0.090mm (0.017). For each outcome measure the 3D templates demonstrated an improvement which was statistically significant (p⟨0.05). 3D printed copy denture templates reproduced the original with greater trueness and precision than conventional techniques. Copyright© 2017 Dennis Barber Ltd.

  6. 21 CFR 872.3410 - Ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide homopolymer and/or....3410 Ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive. (a) Identification. An ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive is a device...

  7. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2016-08-01

    Currently no data comparing the denture base adaptation of CAD-CAM and conventional denture processing techniques have been reported. The purpose of this in vitro study was to compare the denture base adaptation of pack and press, pour, injection, and CAD-CAM techniques for fabricating dentures to determine which process produces the most accurate and reproducible adaptation. A definitive cast was duplicated to create 40 gypsum casts that were laser scanned before any fabrication procedures were initiated. A master denture was made using the CAD-CAM process and was then used to create a putty mold for the fabrication of 30 standardized wax festooned dentures, 10 for each of the conventional processing techniques (pack and press, pour, injection). Scan files from 10 casts were sent to Global Dental Science, LLC for fabrication of the CAD-CAM test specimens. After specimens for each of the 4 techniques had been fabricated, they were hydrated for 24 hours and the intaglio surface laser scanned. The scan file of each denture was superimposed on the scan file of the corresponding preprocessing cast using surface matching software. Measurements were made at 60 locations, providing evaluation of fit discrepancies at the following areas: apex of the denture border, 6 mm from the denture border, crest of the ridge, palate, and posterior palatal seal. The use of median and interquartile range was used to assess accuracy and reproducibility. The Levine and Kruskal-Wallis analysis of variance was used to evaluate differences between processing techniques at the 5 specified locations (α=.05). The ranking of results based on median and interquartile range determined that the accuracy and reproducibility of the CAD-CAM technique was more consistently localized around zero at 3 of the 5 locations. Therefore, the CAD-CAM technique showed the best combination of accuracy and reproducibility among the tested fabrication techniques. The pack and press technique was more accurate at 2 of the 5 locations; however, its interquartile range (reproducibility) was the greatest of the 4 tested processing techniques. The pour technique was the most reproducible at 2 of the 5 locations; however, its accuracy was the lowest of the tested techniques. The CAD-CAM fabrication process was the most accurate and reproducible denture fabrication technique when compared with pack and press, pour, and injection denture base processing techniques. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. 21 CFR 872.3490 - Carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive. 872.3490 Section 872.3490 Food and Drugs... maleic acid calcium-sodium double salt denture adhesive. (a) Identification. A carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive is a device...

  9. 21 CFR 872.3490 - Carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive. 872.3490 Section 872.3490 Food and Drugs... maleic acid calcium-sodium double salt denture adhesive. (a) Identification. A carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive is a device...

  10. 21 CFR 872.3490 - Carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive. 872.3490 Section 872.3490 Food and Drugs... maleic acid calcium-sodium double salt denture adhesive. (a) Identification. A carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive is a device...

  11. 21 CFR 872.3490 - Carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive. 872.3490 Section 872.3490 Food and Drugs... maleic acid calcium-sodium double salt denture adhesive. (a) Identification. A carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive is a device...

  12. 21 CFR 872.3490 - Carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive. 872.3490 Section 872.3490 Food and Drugs... maleic acid calcium-sodium double salt denture adhesive. (a) Identification. A carboxymethylcellulose sodium and/or polyvinylmethylether maleic acid calcium-sodium double salt denture adhesive is a device...

  13. 21 CFR 872.3450 - Ethylene oxide homopolymer and/or karaya denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide homopolymer and/or karaya denture... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3450 Ethylene oxide homopolymer and/or karaya denture adhesive. (a) Identification. Ethylene oxide homopolymer and/or karaya...

  14. A simplified chair-side remount technique using customized mounting platforms.

    PubMed

    Chauhan, Mamta Devendrakumar; Dange, Shankar Pandharinath; Khalikar, Arun Narayan; Vaidya, Smita Padmakar

    2012-08-01

    Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms.

  15. A simplified chair-side remount technique using customized mounting platforms

    PubMed Central

    Dange, Shankar Pandharinath; Khalikar, Arun Narayan; Vaidya, Smita Padmakar

    2012-01-01

    Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms. PMID:22977726

  16. Denture-induced fibrous inflammatory hyperplasia: a retrospective study in a school of dentistry.

    PubMed

    Coelho, C M; Zucoloto, S; Lopes, R A

    2000-01-01

    The aim of this study was to investigate the denture-induced fibrous inflammatory hyperplasia (FIH) that occurs around the borders of an ill-fitting denture, in relation to frequency of the lesion, age and sex distribution, length of denture use, and frequency of dysplasia. A comprehensive review of FIH diagnosed in patients wearing dentures by the oral pathology diagnostic service at the University of São Paulo over 26 years (1971 to 1996) was undertaken, based on retrospective analysis of the oral histopathologic files. The frequency of FIH was 15% of the total number of pathologies diagnosed at the service of oral pathology in that period. The disorder occurred predominantly in the fifth and sixth decades of life and more often among females, at a proportion of 5:1. The frequency of FIH was higher for a length of denture use of between 1 and 10 years. Dysplasia was found in 4% of cases. The knowledge of some aspects of FIH, especially the possible histologic alteration of dysplasia, supports the importance of the diagnosis and treatment of the lesion and suggests that any excised tissue should be submitted to histopathologic evaluation. Education and regular review of patients who have worn dentures are essential if the development of FIH is to be prevented.

  17. Influence of Palatal Coverage and Implant Distribution on Denture Strain in Maxillary Implant Overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Tomita, Akiko; Mizuno, Yoko; Maeda, Yoshinobu

    2016-01-01

    As maxillary implant overdentures are being increasingly used in clinical practice, prosthodontic complications related to these dentures are also reported more often. The purpose of this study was to examine the influence of palatal coverage and implant distribution on the shear strain of maxillary implant overdentures. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar areas was fabricated. Two kinds of experimental overdentures, with and without palatal coverage, were also fabricated, and two strain gauges were attached at the midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain in each denture was compared by analysis of variance (P = .05). In all situations, the shear strain in palateless dentures was significantly higher than in dentures with palate on both sides (P < .05). In dentures with palate, the shear strain was lower when anterior implants were present. Palateless maxillary implant overdentures exhibited much higher strain than overdentures with palate regardless of the implant distribution; this may cause more prosthodontic and implant complications. The most favorable configuration to prevent complications in maxillary implant overdentures was palatal coverage that was supported by more than four widely distributed implants.

  18. Setting up of teeth in the neutral zone and its effect on speech

    PubMed Central

    Al-Magaleh, Wafa’a Radwan; Swelem, Amal Ali; Shohdi, Sahar Saad; Mawsouf, Nadia Mohamed

    2011-01-01

    Rational goals for denture construction are basically directed at the restoration of esthetics and masticatory function and the healthy preservation of the remaining natural tissues. Little concern has been given to the perfection and optimization of the phonetic quality of denture users. However, insertion of prosthodontic restorations may lead to speech defects. Most such defects are mild but, nevertheless, can be a source of concern to the patient. For the dental practitioner, there are few guidelines for designing a prosthetic restoration with maximum phonetic success. One of these guidelines involves the setting up of teeth within the neutral zone. The aim of this study was to evaluate, subjectively and objectively, the effect on speech of setting up teeth in the neutral zone. Three groups were examined: group I (control) included 10 completely dentulous subjects, group II included 10 completely edentulous patients with conventional dentures, and group III included the same 10 edentulous patients with neutral zone dentures. Subjective assessment included patient satisfaction. Objective assessment included duration taken for recitation of Al-Fateha and acoustic analysis. Subjectively, patients were more satisfied with their neutral zone dentures. Objectively, speech produced with the neutral zone dentures was closer to normal than speech with conventional dentures. PMID:23960527

  19. Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis.

    PubMed

    Schwindling, Franz Sebastian; Schwindling, Franz-Peter

    2016-07-01

    The purpose of this study was to assess the survival of mini dental implants (MDI) and to measure prosthetic maintenance needs in a dental practice-based setting. Patients with mandibular removable dentures were provided with MDI to improve denture retention. Complications and maintenance were analyzed by use of patient records and evaluated with Kaplan-Meier curves and the log rank test at a significance level of 0.05. Ninety-nine MDI were placed in 25 patients (mean age: 72 years). Two MDI fractured during placement and eight implants failed during the first weeks. No more implants were lost for up to seven years, resulting in 92% survival. Implant survival differed significantly depending on whether the maxilla was provided with complete dentures (94.9%) or with partial dentures (81%). All prostheses were in use at the time of data extraction. Denture base fractures were observed in six cases, an incidence of fractures of 24%. Some minor intervention was necessary: one resin tooth fractured, retention rings were changed in five cases, and repeated relining was required for 16% of the dentures. After mid-term observation, survival of MDI was good. However, the incidence of denture base fractures and of minor prosthetic complications should not be under-estimated. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. The patient general satisfaction of mandibular single-implant overdentures and conventional complete dentures: Study protocol for a randomized crossover trial.

    PubMed

    Kanazawa, Manabu; Tanoue, Mariko; Miyayasu, Anna; Takeshita, Shin; Sato, Daisuke; Asami, Mari; Lam, Thuy Vo; Thu, Khaing Myat; Oda, Ken; Komagamine, Yuriko; Minakuchi, Shunsuke; Feine, Jocelyne

    2018-05-01

    Mandibular overdentures retained by a single implant placed in the midline of edentulous mandible have been reported to be more comfortable and function better than complete dentures. Although single-implant overdentures are still more costly than conventional complete dentures, there are a few studies which investigated whether mandibular single-implant overdentures are superior to complete dentures when patient general satisfaction is compared. The aim of this study is to assess patient general satisfaction with mandibular single-implant overdentures and complete dentures. This study is a randomized crossover trial to compare mandibular single-implant overdentures and complete dentures in edentulous individuals. Participant recruitment is ongoing at the time of this submission. Twenty-two participants will be recruited. New mandibular complete dentures will be fabricated. A single implant will be placed in the midline of the edentulous mandible. The mucosal surface of the complete denture around the implant will be relieved for 3 months. The participants will then be randomly allocated into 2 groups according to the order of the interventions; group 1 will receive single-implant overdentures first and will wear them for 2 months, followed by complete dentures for 2 months. Group 2 will receive the same treatments in a reverse order. After experiencing the 2 interventions, the participants will choose one of the mandibular prostheses, and yearly follow-up visits are planned for 5 years. The primary outcome of this trial is patient ratings of general satisfaction on 100 mm visual analog scales. Assessments of the prostheses and oral health-related quality of life will also be recorded as patient-reported outcomes. The secondary outcomes are cost and time for treatment. Masticatory efficiency and cognitive capacity will also be recorded. Furthermore, qualitative research will be performed to investigate the factors associated with success of these mandibular denture types. Clinical outcomes, such as implant survival rate, marginal bone loss, and prosthodontic complications, will also be recorded. The results of this randomized crossover trial will clarify whether mandibular single implants and overdentures for edentulous individuals provide better patient general satisfaction when compared to conventional complete dentures. This clinical trial was registered at the University Hospital Medical Information Network (UMIN) Center (UMIN000017883).

  1. Efficacy of citric acid denture cleanser on the Candida albicans biofilm formed on poly(methyl methacrylate): effects on residual biofilm and recolonization process

    PubMed Central

    2014-01-01

    Background It is well known that the use of denture cleansers can reduce Candida albicans biofilm accumulation; however, the efficacy of citric acid denture cleansers is uncertain. In addition, the long-term efficacy of this denture cleanser is not well established, and their effect on residual biofilms is unknown. This in vitro study evaluated the efficacy of citric acid denture cleanser treatment on C. albicans biofilm recolonization on poly(methyl methacrylate) (PMMA) surface. Methods C. albicans biofilms were developed for 72 h on PMMA resin specimens (n = 168), which were randomly assigned to 1 of 3 cleansing treatments (CTs) overnight (8 h). CTs included purified water as a control (CTC) and two experimental groups that used either a 1:5 dilution of citric acid denture cleanser (CT5) or a 1:8 dilution of citric acid denture cleanser (CT8). Residual biofilms adhering to the specimens were collected and quantified at two time points: immediately after CTs (ICT) and after cleaning and residual biofilm recolonization (RT). Residual biofilms were analyzed by quantifying the viable cells (CFU/mL), and biofilm architecture was evaluated by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Denture cleanser treatments and evaluation periods were considered study factors. Data were analyzed using two-way ANOVA and Tukey’s Honestly Significant Difference (HSD) test (α = 0.05). Results Immediately after treatments, citric acid denture cleansing solutions (CT5 and CT8) reduced the number of viable cells as compared with the control (p < 0.01). However, after 48 h, both CT groups (CT5 and CT8) showed biofilm recolonization (p < 0.01). Residual biofilm recolonization was also detected by CLSM and SEM analysis, which revealed a higher biomass and average biofilm thickness for the CT8 group (p < 0.01). Conclusion Citric acid denture cleansers can reduce C. albicans biofilm accumulation and cell viability. However, this CT did not prevent biofilm recolonization. PMID:24957210

  2. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups

    PubMed Central

    Muddugangadhar, B. C.; Sangur, Rajashekar; Rudraprasad, I. V.; Nandeeshwar, D. B.; Kumar, B. H. Dhanya

    2015-01-01

    Purpose: This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Materials and Methods: Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Results: Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Conclusion: Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. Clinical Implications: The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics. PMID:26929540

  3. [All-ceramic resin bonded fixed partial denture made of IPS hot-pressed casting porcelain restore anterior missing teeth: a three years clinical observation].

    PubMed

    Zhou, Tuan feng; Wang, Xin zhi; Zhang, Gui rong

    2011-02-18

    To clinic observation of IPS Empress2 and IPS e.max all ceramic resin bonded fixed partial dentures used in one anterior teeth lost in upper jaw or less than two anterior tooth lost in lower jaw. 22 patients, 26 restorations had been made, which included 16 single-retainer all ceramic resin bonded fixed partial dentures and 10 two-retainers all ceramic resin bonded fixed partial dentures. Secondary caries of the abutments, shade in the margin of the retainers and the integrity of the restorations had been observed at 3 months, 6 months, 1 year, 2 years and 3 years after all ceramic resin bonded fixed partial dentures having been bonded. In the 3 years of clinic observation of the anterior all ceramic resin bonded fixed partial dentures, 1 two-retainers restoration lost bond after it had been made for 3 months, a retainer of one two-retainers restoration was broken after 6 months, but they are still used after modified as one-retainer all ceramic resin bonded fixed partial dentures, 1 two-retainers restoration lost bond two year later, It was integrity and re-bonded again that was still stable. No secondary carries and no shade in margin of the retainers had been found. Their color matches with the nature teeth excellently. The success rate was 88.5%. IPS Empress 2 and IPS e.max all ceramic resin bonded fixed partial dentures should be a good selection in one or two teeth lose in anterior jaws.

  4. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups.

    PubMed

    Muddugangadhar, B C; Sangur, Rajashekar; Rudraprasad, I V; Nandeeshwar, D B; Kumar, B H Dhanya

    2015-01-01

    This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics.

  5. Color Stability of Heat-cure Acrylic Resin Subjected to Simulated Short-term Immersion in Fast-acting Denture Cleansers.

    PubMed

    Lohitha, K; Prakash, M; Gopinadh, A; Sai Sankar, A J; Sandeep, C H; Sreedevi, B

    2016-01-01

    Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat-cure denture base resin. The aim of the present study was to evaluate the effect of commercially available fast-acting denture cleansers on the color stability of heat-cure denture base resin at different time intervals. Thirty-six heat-cure acrylic resin (Ivoclar Triplex Hot-V) specimens are randomly allocated into four groups - Group A (distilled water as control); Group B (polident - 3 min); Group C (fixodent scope plus); and Group D (stain away plus) comprising of nine samples each. After recording the baseline values, the specimens were immersed in their respective cleansing solutions for a prescribed time interval. This procedure was repeated daily, and the color change (ΔE) was evaluated after 90 and 180 days interval using a colorimeter in a standard "Commission International de l'Eclairage" color system. Paired t -test and Dunnett's T3 test. All the groups exhibited a variable color change (ΔE) for an immersion period of 90 days. However, significant color differences ( P = 0.001) were noticed among the test groups after 180 days. The color change of denture base resin was greater for Group D followed by Groups B, C, and A respectively after 180 days of immersion. The ΔE values of all test groups increased with time.

  6. The effect of long-term disinfection procedures on hardness property of resin denture teeth.

    PubMed

    Campanha, Nara Hellen; Pavarina, Ana Cláudia; Jorge, Janaina Habib; Vergani, Carlos Eduardo; Machado, Ana Lucia; Giampaolo, Eunice Teresinha

    2012-06-01

    The aim of the study was to evaluate the effect of long-term disinfection procedures on the Vickers hardness (VHN) of acrylic resin denture teeth. Five acrylic resin denture teeth (Vipi Dent Plus-V, Trilux-T, Biolux-B, Postaris-P and Artiplus-A) and one composite resin denture teeth (SR-Orthosit-O) were embedded in heat-polymerised acrylic resin within polyvinylchloride tubes. Specimens were stored in distilled water at 37°C for 48 h. Measurements of hardness were taken after the following disinfection procedures: immersion for 7 days in 4% chlorhexidine gluconate or in 1% sodium hypochlorite (CIm and HIm group, respectively) and seven daily cycles of microwave sterilisation at 650 W for 6 min (MwS group). In the WIm group, specimens were maintained in water during the time used to perform the disinfection procedures (7 days). Data were analysed with anova followed by the Bonferroni procedure (α = 0.01). Microwave disinfection decreased the hardness of all acrylic resin denture teeth (p < 0.001). Immersion for 7 days in 4% chlorhexidine gluconate or distilled water had significant effect on the hardness of the acrylic resin denture teeth A (p < 0.01), and 1% sodium hypochlorite on teeth T (p < 0.01). All disinfection procedures decrease the hardness of the composite resin denture teeth (p < 0.01). Teeth O exhibited the highest and teeth V the lowest hardness values in the control group (p < 0.01). Disinfection procedures changed the hardness of resin denture teeth. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  7. Evaluation of the durability and antiadhesive action of 2-methacryloyloxyethyl phosphorylcholine grafting on an acrylic resin denture base material.

    PubMed

    Takahashi, Nana; Iwasa, Fuminori; Inoue, Yuuki; Morisaki, Hirobumi; Ishihara, Kazuhiko; Baba, Kazuyoshi

    2014-08-01

    The polymer 2-methacryloyloxyethyl phosphorylcholine is currently used on medical devices to prevent infection. Denture plaque-associated infection is regarded as a source of serious dental and medical complications in the elderly population, and denture hygiene, therefore, is an issue of considerable importance for denture wearers. Furthermore, because denture bases are exposed to mechanical stresses, for example, denture brushing, the durability of the coating is important for retaining the antiadhesive function of 2-methacryloyloxyethyl phosphorylcholine. The purpose of this study is to investigate the durability and antiadhesive activity of two 2-methacryloyloxyethyl phosphorylcholine polymer coating techniques: poly-2-methacryloyloxyethyl phosphorylcholine grafting and poly-2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate coating. It was revealed that 2-methacryloyloxyethyl phosphorylcholine polymer coating of the denture base resin polymethyl methacrylate decreases bacterial biofilm formation. Durability was examined by rhodamine staining and elemental surface analysis and by determining the wetting properties of the 2-methacryloyloxyethyl phosphorylcholine polymer-modified polymethyl methacrylate after a friction test that comprised 500 brushing cycles. Antiadhesive activity was examined by using a Streptococcus mutans biofilm formation assay. Poly-2-methacryloyloxyethyl phosphorylcholine-grafted polymethyl methacrylate retained 2-methacryloyloxyethyl phosphorylcholine units and antiadhesive activity even after repetitive mechanical stress, whereas co-n-butyl methacrylate-coated polymethyl methacrylate did not. These results demonstrated that graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on denture surfaces may contribute to the durability of the coating and prevent microbial retention. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. 21 CFR 872.3560 - OTC denture reliner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false OTC denture reliner. 872.3560 Section 872.3560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... OTC denture reliner is a device consisting of a material such as plastic resin that is intended to be...

  9. 21 CFR 872.3560 - OTC denture reliner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false OTC denture reliner. 872.3560 Section 872.3560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... OTC denture reliner is a device consisting of a material such as plastic resin that is intended to be...

  10. 21 CFR 872.3560 - OTC denture reliner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false OTC denture reliner. 872.3560 Section 872.3560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... OTC denture reliner is a device consisting of a material such as plastic resin that is intended to be...

  11. 21 CFR 872.3560 - OTC denture reliner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false OTC denture reliner. 872.3560 Section 872.3560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... OTC denture reliner is a device consisting of a material such as plastic resin that is intended to be...

  12. Treatment of edentulism: optimizing outcomes with tissue management and impression techniques.

    PubMed

    Salinas, Thomas J

    2009-02-01

    Significant numbers of patients throughout the world seek treatment for edentulism. The trend toward tissue-integrated prostheses has been a monumental step in restoring edentulous patients to function; however, this treatment can be out of reach for those who fail to qualify or those who do not have sufficient resources to afford it. In these cases, conventional dentures remain an important primary course of treatment. Attention to detail when diagnosing, treatment planning, and performing treatment for these patients is still a prime consideration for the best possible outcome. In particular, many experienced denture wearers are afflicted with chronically inflamed denture-bearing mucosa. Clinicians must recognize the need for tissue conditioning, choices of impression materials, and accepted fabrication techniques that can have favorable outcomes when matched with patients who are philosophical and realistic in their expectations. The purpose of this article is to review impression philosophies, associated materials, and methods of tissue conditioning. Retention and stability of the denture bases can be augmented by the routine use of denture adhesive, and indications for use of denture adhesive will be discussed.

  13. The Role of New Removable Complete Dentures in Stimulated Salivary Flow and Taste Perception.

    PubMed

    Tango, Rubens Nisie; Arata, Anelyse; Borges, Alexandre Luiz Souto; Costa, Anna K F; Pereira, Luciano Jose; Kaminagakura, Estela

    2018-04-01

    To evaluate the effect of replacement of inadequate complete dentures on salivary flow and taste perception in geriatric patients. Thirty-three patients, 13 males and 20 females, with a mean age of 64.4 years were submitted to stimulated and unstimulated salivary flow rate and salivary pH measurements, and sense of taste evaluation. Tests were performed 3 months before complete denture substitution and 3 weeks after denture insertion. The mean for unstimulated saliva (USS) was 2.1 ml before and 2.7 ml after replacement (p = 0.003). The mean volume of stimulated saliva was 6.3 ml before and 8.2 ml after replacement (p = 0.004). The pH mean of USS was 7.8 ± 0.44 before and 8.02 ± 0.41 after replacement (p = 0.005). No statistically significant difference was determined in the sense of taste before and 3 weeks after complete denture replacement. The replacement of inadequate complete dentures increases saliva flow; however, it does not improve taste perception. © 2016 by the American College of Prosthodontists.

  14. Reliability and validity of a questionnaire for self-assessment of complete dentures.

    PubMed

    Komagamine, Yuriko; Kanazawa, Manabu; Kaiba, Yoshinori; Sato, Yusuke; Minakuchi, Shunsuke

    2014-05-02

    Demand for complete denture treatment is expected to rise over several decades. However, to date, no questionnaire on complete dentures, as evaluated by edentulous patients, has been shown to be reliable and valid. This study sought to assess the reliability and validity of Patient's Denture Assessment (PDA), which provides a multidimensional evaluation of dentures among edentulous patients. Patients, who had new complete dentures fabricated at the University Hospital of Dentistry, Tokyo Medical and Dental University through 2009 to 2010, were enrolled. The reliability of the PDA was determined by examining internal consistency and test-retest reliability. Internal consistency for all of the question items and the six subscales was measured using Cronbach's α and average inter-item correlation coefficients among 93 participants. For 33 of these participants, test-retest reliability was determined at a 2 month-interval using the interclass correlation coefficients (ICCs) and 95% confidence interval for the summary scores and the six subscale scores. The PDA was validated in 93 participants by examining the difference in the summary score and the six subscale scores of the PDA before and after replacement with new dentures by the paired t-test. Ability to detect change was also tested in 93 patients using effect size. The Cronbach's α for the PDA ranged from 0.56 to 0.93. The average inter-item correlation coefficients ranged from 0.28 to 0.83. ICCs for the PDA ranged from 0.37 to 0.83. The paired t-test showed a significant difference between the summary score and the six subscale scores before and after replacement with new dentures (p < 0.05) and the effect size was 0.97. The PDA demonstrated good reliability by assessing internal consistency and test-retest reliability. In addition, the PDA demonstrated good validity by assessing discriminant validity. Thus, the PDA could help dentists obtain a detailed understanding of the patients' perceptions in using their dentures.

  15. In vitro comparison of the tensile bond strength of denture adhesives on denture bases.

    PubMed

    Kore, Doris R; Kattadiyil, Mathew T; Hall, Dan B; Bahjri, Khaled

    2013-12-01

    With several denture adhesives available, it is important for dentists to make appropriate patient recommendations. The purpose of this study was to evaluate the tensile bond strength of denture adhesives on denture base materials at time intervals of up to 24 hours. Fixodent, Super Poligrip, Effergrip, and SeaBond denture adhesives were tested with 3 denture base materials: 2 heat-polymerized (Lucitone 199 and SR Ivocap) and 1 visible-light-polymerized (shade-stable Eclipse). Artificial saliva with mucin was used as a control. Tensile bond strength was tested in accordance with American Dental Association specifications at 5 minutes, 3 hours, 6 hours, 12 hours, and 24 hours after applying the adhesive. Maximum forces before failure were recorded in megapascals (MPa), and the data were subjected to a 2-way analysis of variance (α=.05). All 4 adhesives had greater tensile bond strength than the control. Fixodent, Super Poligrip, and SeaBond had higher tensile bond strength values than Effergrip. All adhesives had the greatest tensile bond strength at 5 minutes and the least at 24 hours. The 3 denture bases produced significantly different results with each adhesive (P<.001). Lucitone 199 with the adhesives had the greatest tensile bond strength, followed by Ivocap and Eclipse. All 4 adhesives had greater tensile bond strength than the control, and all 4 adhesives were strongest at the 5-minute interval. On all 3 types of denture bases, Effergrip produced significantly lower tensile bond strength, and Fixodent, Super Poligrip, and SeaBond produced significantly higher tensile bond strength. At 24 hours, the adhesive-base combinations with the highest tensile bond strength were Fixodent on Lucitone 199, Fixodent on Eclipse, Fixodent on Ivocap, and Super Poligrip on Ivocap. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  16. Laser micro-etching of metal prostheses for personal identification

    PubMed Central

    Ganapathy, Dhanraj; Sivaswamy, Vinay; Sekhar, Prathap

    2017-01-01

    Denture marking techniques play a vital role in establishing personal identification in suitable clinical and forensic situations. The denture marking techniques are categorized broadly into additive and ablative methods. Additive methods involve embedding or impregnation of markers for establishing personal identity. Ablative methods involve partial removal of the denture surface thereby providing a marking for identification. Engraving and etching methods are the commonly used ablative methods. Ablative methods can be of contact and noncontact subtypes. Laser micro-etching is a precise noncontact ablative denture marking technique that could be used for prostheses-guided personal identification. PMID:28584473

  17. Laser micro-etching of metal prostheses for personal identification.

    PubMed

    Ganapathy, Dhanraj; Sivaswamy, Vinay; Sekhar, Prathap

    2017-01-01

    Denture marking techniques play a vital role in establishing personal identification in suitable clinical and forensic situations. The denture marking techniques are categorized broadly into additive and ablative methods. Additive methods involve embedding or impregnation of markers for establishing personal identity. Ablative methods involve partial removal of the denture surface thereby providing a marking for identification. Engraving and etching methods are the commonly used ablative methods. Ablative methods can be of contact and noncontact subtypes. Laser micro-etching is a precise noncontact ablative denture marking technique that could be used for prostheses-guided personal identification.

  18. Prosthodontic management of worn dentition in pediatric patient with complete overlay dentures: a case report

    PubMed Central

    Rastogi, Jyoti; Jain, Chandni; Singh, Harkanwal Preet

    2012-01-01

    Overlay complete dentures are simple, reversible and economical treatment modality for patients with congenital or acquired disorders that severely affect the tooth development. It satisfies both the esthetic and functional demands where the extraction of teeth is not generally indicated. In pediatric patients, the overlay dentures establish a relatively stable occlusion that improves patient's tolerance to the future treatment procedures for worn dentition. This clinical report highlights the imperative need of appropriate treatment strategy and application of maxillary and mandibular overlay dentures in a pediatric patient who suffered from congenitally mutilated and worn dentition. PMID:23236577

  19. A novel design solution to the fraenal notch of maxillary dentures.

    PubMed

    White, J A P; Bond, I P; Jagger, D C

    2013-09-01

    This study investigates a novel design feature for the fraenal notch of maxillary dentures, using computational and experimental methods, and shows that its use could significantly increase the longevity of the prosthesis. A two-step process can be used to create the design feature with current denture base materials, but would be highly dependent on the individual skill of the dental technician. Therefore, an alternative form of manufacture, multi-material additive layer manufacture (or '3D printing'), has been proposed as a future method for the direct production of complete dentures with multi-material design features.

  20. The Use of Implants to Improve Removable Partial Denture Function.

    PubMed

    Pimentel, Marcele Jardim; Arréllaga, Juan Pablo; Bacchi, Ataís; Del Bel Cury, Altair A

    2014-12-01

    The oral rehabilitation with conventional removable partial dentures in Kennedy class I patients allows continuous bone resorption, dislodgment of the prosthesis during the mastication caused by the resilience of the mucosa, and rotation of the prosthesis. Thus, the associations of distal implants become an attractive modality of treatment for these patients. This case report presented an association of removable partial dentures, milled crowns and osseointegrated implants to rehabilitate a partial edentulous patient. A removable partial denture associated with implants and metal-ceramic milled crowns can offer excellent esthetics, and will improve function and biomechanics, at a reduced cost.

  1. Three-year clinical outcome of single implant-retained mandibular overdentures--results of preliminary prospective study.

    PubMed

    Harder, Sönke; Wolfart, Stefan; Egert, Christopher; Kern, Matthias

    2011-10-01

    The aim of this preliminary prospective study was to evaluate the clinical outcome, the oral health-related quality of life (OHRQoL), and the subjective chewing ability of patients with mandibular complete dentures retained by a single implant placed in the mandible midline. Patients wearing complete dentures were treated with a single implant in the mandible, followed by relining of the dentures and incorporation of ball attachments for implant retention. Implant outcome, prosthodontic maintenance, subjective chewing ability, and the oral health impact profile of the patients were assessed at baseline and at four weeks after connecting the denture and implant. Eleven patients were enrolled in this investigation, and the mean observation period was 43.4 months (minimum period: 35, maximum period: 52 months). No implants were lost during observation period, but four dentures needed repair because of the fracture of the denture base in the midline area. A significant improvement was observed in the OHRQoL of the patients after the attachment of the mandibular dentures with a single midline implant. Furthermore, the subjective chewing ability of the patients was significantly improved after implant connection. Within the limitations of this preliminary prospective clinical study, single implant-supported mandibular overdentures were a successful treatment option for older edentulous patients who showed improvements in their OHRQoL and chewing ability. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Wispy Prosthesis: A Novel Method in Denture Weight Reduction

    PubMed Central

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Peddinti, Vijaya Kumar

    2016-01-01

    Introduction Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. Aim To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Materials and Methods Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. Results It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. Conclusion This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis. PMID:27190947

  3. Wispy Prosthesis: A Novel Method in Denture Weight Reduction.

    PubMed

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Appana, Krishna Chaitanya; Peddinti, Vijaya Kumar

    2016-04-01

    Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis.

  4. A radiographic template for a two-implant mandibular overdenture using the patient’s existing denture

    PubMed Central

    Huynh-Ba, G; Alexander, P; Vargas, A; Vierra, M; Oates, TW

    2012-01-01

    This article introduces a technique for modifying an existing mandibular complete denture for use as a radiographic template with a radiopaque light-activated calcium hydroxide (Ca(OH)2) preparation. This allows prosthetically-driven treatment planning and surgical placement of 2 implants to support the existing mandibular denture. PMID:23328197

  5. Individualized Plastic Reconstruction Strategy for Patients With Ectodermal Dysplasia Syndrome.

    PubMed

    Hou, Yikang; Jin, Yunbo; Lin, Xiaoxi; Chai, Gang; Zhang, Yan; Qi, Zuoliang

    2017-06-01

    Ectodermal dysplasia syndrome is a hereditary disease of ectodermal origin. Appearances of nail dystrophy, alopecia or hypotrichosis, saddle nose deformity, and palmoplantar hyperkeratosis are usually associated with a lack of sweat glands as well as partial or complete absence of teeth. These manifestations are usually corrected only with oral rehabilitation by mounting dentures. In this study, plastic rehabilitation was developed to correct the special features of patients with ectodermal dysplasia. Four men and 1 woman with ectodermal dysplasia syndrome were treated. Four patients showed dysostosis of the midface, and rhinoplasty with costal bone was performed, whereas cosmetic operation aiming to repair soft tissue defects was adopted for the last patient. After plastic corrections, all 5 patients were satisfied with the results and had no social embarrassment.

  6. Real-time structured light intraoral 3D measurement pipeline

    NASA Astrophysics Data System (ADS)

    Gheorghe, Radu; Tchouprakov, Andrei; Sokolov, Roman

    2013-02-01

    Computer aided design and manufacturing (CAD/CAM) is increasingly becoming a standard feature and service provided to patients in dentist offices and denture manufacturing laboratories. Although the quality of the tools and data has slowly improved in the last years, due to various surface measurement challenges, practical, accurate, invivo, real-time 3D high quality data acquisition and processing still needs improving. Advances in GPU computational power have allowed for achieving near real-time 3D intraoral in-vivo scanning of patient's teeth. We explore in this paper, from a real-time perspective, a hardware-software-GPU solution that addresses all the requirements mentioned before. Moreover we exemplify and quantify the hard and soft deadlines required by such a system and illustrate how they are supported in our implementation.

  7. Influence of guidance concept in complete dentures on oral health related quality of life - Canine guidance vs. bilateral balanced occlusion.

    PubMed

    Schierz, Oliver; Reissmann, Daniel

    2016-10-01

    To compare the impact of canine guided vs. bilateral balanced occlusion on oral health related quality of life (OHRQoL) as a patient-reported outcome measure. In this randomized single-blind crossover trial, 19 patients have been provided with new complete dentures in the maxilla and mandible. OHRQoL was assessed using the 49-item Oral Health Impact Profile (OHIP-49) before the start of the prosthodontic treatment (B), 3 months after insertion of the new dentures (T1), and 3 months after rework into the alternative concept (T2). Multilevel mixed-effect linear regression models were computed to determine the effect provided by the new set of dentures and the specific impact of the occlusal concept on OHRQoL using summary scores of the OHIP-49 and of a 19-items subset specific for edentulous patients (OHIP-EDENT). At baseline, participants' OHRQoL was substantially impaired indicated by an average OHIP-49 score of 42.1 points and an OHIP-EDENT score of 21.1 points. The effect of provision of a new set of complete dentures was a statistically significant decrease of 8.3 points (OHIP-49) and 4.0 points (OHIP-EDENT), respectively, representing a clinically relevant improvement in OHRQoL. When wearing dentures with bilateral balanced occlusion, participants showed on average 1.6 points higher OHIP-49 scores and 0.9 points higher OHIP-EDENT scores compared to canine guided dentures. This effect of the occlusal concept was neither statistically nor clinically significant. Both investigated occlusal concepts for complete dentures were comparable in their effect on patients' perceptions with none being considerably superior in terms of OHRQoL. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  8. A randomised controlled trial of complete denture impression materials.

    PubMed

    Hyde, T P; Craddock, H L; Gray, J C; Pavitt, S H; Hulme, C; Godfrey, M; Fernandez, C; Navarro-Coy, N; Dillon, S; Wright, J; Brown, S; Dukanovic, G; Brunton, P A

    2014-08-01

    There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7-67.3%, p<0.0001). There is significant evidence that dentures made from silicone impressions were preferred by patients. Given the strength of the clinical findings within this paper, dentists should consider choosing silicone rather than alginate as their material of choice for secondary impressions for complete dentures. ISRCTN 01528038. This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

    PubMed Central

    2014-01-01

    PURPOSE This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and 100 µL of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at 37℃ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe. RESULTS PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted. CONCLUSION This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required. PMID:25006385

  10. Influence of denture adhesives on occlusion and disocclusion times.

    PubMed

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (P<.001) in stability and retention and a significant decrease in duration of all occlusal parameters (OT [P=.003], DT-right [P=.003], and DT-left [P=.008]). Adhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Electromyographic evaluation of masseter and anterior temporalis muscles in rest position of edentulous patients with temporomandibular disorders, before and after using complete dentures with sliding plates.

    PubMed

    Zuccolotto, Maria Cristina Candelas; Vitti, Mathias; Nóbilo, Krunislave Antônio; Regalo, Simone Cecílio Hallak; Siéssere, Selma; Bataglion, César

    2007-06-01

    This study was performed with the purpose of investigating electromyographic (EMG) activity of the anterior temporalis and masseter muscles in edentulous individuals with temporomandibular disorder (TMD), before and after using sliding plates on complete dentures in the mandibular rest position. Edentulous patients may present TMD, which is characterised by pain in temporomandibular joints, masticatory and neck muscles, uncoordinated and limited mandible movements, joint sounds and an altered occlusal relationship. It is imperative to offer treatment in order to re-establish stomatognathic system structures before submitting the individual to any definitive restorative treatment. The patients were edentulous for at least 10 years. EMG recordings were made before the insertion of the dentures (0 months) and also after using the sliding plates at the fourth month, 9th month and 12th month, using computerised electromyography K6-I/ EMG Light Channel Surface. EMG evaluations of the muscles were performed under the following clinical conditions: rest position with dentures (R1), rest position without dentures (R2), rest position with dentures post-activity (chewing) (R3), rest position without dentures post-activity (chewing) (R4). All patients obtained remission of muscular fatigue and reduced pain in stomatognathic system structures. Temporalis muscle showed significant increase in EMG activity compared with initial values (p < 0.01). Masseter muscles showed significantly lower mean values (p < 0.01) compared with initial values. The sliding plates allowed the process of neuromuscular deprogramming, contributing to muscular balance of the masticatory system, and are therefore indicated to be used before the fabrication of definitive complete dentures in patients with TMD.

  12. Resilient Attachments as an Alternative to Conventional Cast Clasp Removable Partial Denture: 3-Year Follow-up.

    PubMed

    Schuh, Cristian; Adiel Skupien, Jovito; Mesko, Mauro Elias; Valentini, Fernanda; Pereira-Cenci, Tatiana; Boscato, Noéli

    2014-12-01

    The present clinical report describes the prosthodontic management for a patient with uncontrolled bleeding and diabetes mellitus treated with a maxillary complete denture and a mandibular partial fixed dental prosthesis designed to interface with a removable cast framework partial denture retained by 2 ERA attachments. This approach was undertaken to improve both retention and stability of the distal extension Kennedy Class I removable partial denture. The rehabilitation provided better anterior esthetics than if treated with a conventional clasp retained removable partial denture, by employing a simple, practical design and offering a significant biomechanical advantages, restoring both oral health and function. Thus, this treatment modality, involving an ERA system and transfixation in fixed crowns, is an effective treatment and can be indicated as a clinical alternative for edentulous and partially edentulous patients with systemic disorders or for patients in economic situations that might preclude implant-based rehabilitation.

  13. Prosthodontics an “arsenal” in forensic dentistry

    PubMed Central

    Bathala, Lakshmana Rao; Rachuri, Narendra Kumar; Rayapati, Srinivas Rao; Kondaka, Sudheer

    2016-01-01

    After major disasters such as earthquakes, fires, floods, tsunami, bomb blasts or terrorist attacks, accurate, and early identification of the dead and injured becomes an utmost importance. Restorations, cariesteeth, missingteeth and/or prostheses are most useful aids for the dental identification. At times, only identifiable remains are a victim's partial or complete dentures. The central principle of dental identification is that postmortem dental remains can be compared with antemortem dental records which include, studycasts, radiographs, etc., to confirm the identity of the victims. Marking/labeling dentures have been considered an important aid in forensic dentistry. Other than finger printing, when compared with all the methods, the marking/labeling of dentures is an accurate and rapid method to identify the unknown victims. There are no standardized methods to follow, but dental practitioners needs to maintain some dental records of their patients. This may include documentation of the “marking of dentures.” The preparedness is the key to success in mass disaster identification. The aim of this review article is to discuss the methods of denture identification, advantages of denture labeling for the rapid identification during major disasters/accidents and the importance of maintaining the patient records. PMID:28123274

  14. Stress analysis in oral obturator prostheses: imaging photoelastic

    NASA Astrophysics Data System (ADS)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Haddad, Marcela Filié; Andreotti, Agda Marobo; Moreno, Amália

    2013-06-01

    Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning.

  15. The needs of denture-brushing in geriatrics: clinical aspects and perspectives.

    PubMed

    Berteretche, Marie-Violaine; Mastari, Fatima; Nicolas, Emmanuel; Hüe, Olivier

    2012-06-01

    Oral and denture hygiene are often defective in particular with dependent persons such as geriatric subjects. The reasons are the lack of hygiene education of the subjects or those caring for them. Consequently, oral hygiene is often neglected, resulting in poor oral health and an increase in the presence of local or general infections. This paper is a report of brushing effectiveness on microbial biofilm deposits on dentures of subjects participating in a specific oral hygiene programme. Thirty-nine dentures of 30 subjects were assessed for 2 weeks following an educational brushing programme. Microbial biofilm was recovered using fluoresceine and then scanned and quantified by 'Mesurim' software three times: before study, after 1 and 2 weeks. The repeated measurement procedures showed a decrease in the percentage of biofilm present (F = 15, p < 0.001) whatever the type of denture (partial or complete) and for all biomaterials. Regular denture-brushing can improve local hygiene. Consequently, decreasing the biofilm surface can reduce the prevalence of oral pathogens, thereby contributing to the general prevention of the risks of infections such as pneumotisis. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  16. Studies on adaptation to complete dentures. Part II: Oral stereognosis and tactile sensibility.

    PubMed

    Müller, F; Link, I; Fuhr, K; Utz, K H

    1995-10-01

    High oral perception is thought to contribute to poor adaptation to new dentures. The aim of this study was to evaluate the oral stereognosis and tactile sensibility in edentate subjects and relate these to patient age and capability of adaptation to new prostheses. A total of 67 patients were provided with new complete dentures 2-3 weeks before the experiment. In 54 subjects, the oral stereognosis was evaluated by 12 different test-pieces, which were placed unseen on the tongue and had to be recognized. In 38 patients, the oral tactile sensibility was determined in the premolar area using copper foils. The capability of adaptation was evaluated by a questionnaire. Denture retention was assessed by clinical examination. The number of correctly identified test-pieces and the average identification time were related to the age, but no relation was found to patients' capability of adaptation. The tactile sensibility was found to be impaired with age and diminished capability of adaptation. Both adaptation and oral tactile sensibility were significantly lower in subjects with poor lower-denture retention. In conclusion, the results cannot support a relationship between high oral stereognosis and adaptation problems. However, good denture retention facilitates the adaptation process.

  17. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases

    PubMed Central

    Alammari, Manal Rahma

    2017-01-01

    Background Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. Objective The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. Methods This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. Results One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p1<0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Conclusion Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability. PMID:29238483

  18. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.

    PubMed

    Alammari, Manal Rahma

    2017-10-01

    Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 <0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability.

  19. Residual methyl methacrylate monomer, water sorption, and water solubility of hypoallergenic denture base materials.

    PubMed

    Pfeiffer, Peter; Rosenbauer, Ernst-Ulrich

    2004-07-01

    Denture base materials have the potential to cause irritation and allergic reaction to the oral mucosa. Water sorption and water solubility of denture base resins affect dimensional behavior and denture stability. A correlation between residual monomer and water sorption exists. This in vitro study compared the amount of residual monomer, quantity of water sorption, and solubility of 4 denture base materials purported to be hypoallergenic with those of a polymethyl methacrylate-based (PMMA) heat-polymerizing acrylic resin. The denture base resins Sinomer (heat-polymerized, modified methacrylate), Polyan (thermoplastic, modified methacrylate), Promysan (thermoplastic, enterephthalate-based), and Microbase (microwave polymerized, polyurethane-based), which are purported to be hypoallergenic, and Paladon 65 (heat-polymerized, methacrylate, control group) were examined. Specimens of each material were tested for residual methyl methacrylate (MMA) monomer (% wt, n=3), amount of water sorption (microg/mm3, n=5) and water solubility (microg/mm3, n=5), according to ISO 1567:2000. The residual MMA monomer concentrations were determined by gas chromatography (GC). The data were analyzed with 1-way ANOVA and the Bonferroni-Dunn multiple comparisons post hoc analysis for each test variable (alpha=.05). Significantly lower residual MMA monomer was shown for Sinomer and Polyan compared to the PMMA control group (0.90 +/- 0.20% wt, P<.05). Sinomer contained 0.31% +/- 0.00% wt MMA monomer, and Polyan exhibited residual MMA monomer content of 0.44% +/- 0.01% wt. Promysan and Microbase did not contain detectable residual MMA. Water sorption of Promysan (16.21 +/- 0.96 microg/mm3) was significantly lower than Paladon 65 (23.04 +/- 3.13 microg/mm3, P<.0001), whereas water solubility of the hypoallergenic denture base materials (0.34-0.84 +/- 0.05-0.09 microg/mm3) was not significantly lower than the PMMA material (0.40 +/- 0.06 microg/mm3, P>.05). Except for Sinomer, the tested denture base resins passed the requirements of ISO 1567 regarding residual MMA monomer (<2.2% wt). Sinomer failed to comply with the requirements for residual MMA monomer because the manufacturer claimed that the material did not contain any MMA. The tested denture base materials fulfilled the requirements regarding water sorption (<32 microg/mm3) and solubility (<1.6 microg/mm3). The tested hypoallergenic denture base materials exhibited significantly lower residual monomer content than PMMA. Promysan and Microbase showed no detectable residual MMA.

  20. The Soft Palate Friendly Speech Bulb for Velopharyngeal Insufficiency.

    PubMed

    Kahlon, Sukhdeep Singh; Kahlon, Monaliza; Gupta, Shilpa; Dhingra, Parvinder Singh

    2016-09-01

    Velopharyngeal insufficiency is an anatomic defect of the soft palate making palatopharyngeal sphincter incomplete. It is an important concern to address in patients with bilateral cleft lip and palate. Speech aid prosthesis or speech bulbs are best choice in cases where surgically repaired soft palate is too short to contact pharyngeal walls during function but these prosthesis have been associated with inadequate marginal closure, ulcerations and patient discomfort. Here is a case report of untreated bilateral cleft lip and palate associated with palatal insufficiency treated by means of palate friendly innovative speech bulb. This modified speech bulb is a combination of hard acrylic and soft lining material. The hard self-curing acrylic resin covers only the hard palate area and a permanent soft silicone lining material covering the soft palate area. A claw-shaped wire component was extended backwards from acrylic and was embedded in soft silicone to aid in retention and approximation of two materials. The advantage of adding the soft lining material in posterior area helped in covering the adequate superior extension and margins for maximal pharyngeal activity. This also improved the hypernasality, speech, comfort and overall patient acceptance.

  1. Oral malodor and removable complete dentures in the elderly.

    PubMed

    Nalcaci, Rana; Baran, Ilgi

    2008-06-01

    The objectives of this study were to assess oral malodor in patients with removable complete dentures and analyze its association with age, sex, subjective oral dryness, burning mouth, tongue coating, and overnight denture wear in elderly subjects. The study comprised 105 complete denture wearers (56 male, 49 female) between the ages of 50 and 78 from the province of Kirikkale in the Central Anatolia Region of Turkey. Oral malodor was assessed using a portable sulfide monitor. Participants were given a self-administered, structured questionnaire. Baseline and final volatile sulfur compound (VSC) levels and tongue-coating scores (TCS) were measured. Analysis included frequency, cross-tabulations, ANOVA, and independent sample and paired t tests. Odds ratios of VSC-related factors were also calculated. A P value less than .05 was considered statistically significant. There was no significant correlation found between age, gender, smoking, existence of a medical condition, or regular use of medication and VSC levels in mouth air (P > .05). However, educational level (P < .05), oral dryness (P < .05), burning mouth (P < .05), overnight denture wear (P < .01), and TCS (P < .001) were found to be significantly correlated with VSC levels. Significant differences were also found between baseline and final measurements of both VSC levels and TCS (P < .01). This study found the accumulation of bacterial plaque on the tongue, oral dryness, burning mouth, overnight denture wear, and lower educational levels to be significantly related to oral malodor. Following tongue care maintenance and overnight removal of dentures, patients' oral malodor levels decreased significantly.

  2. Tooth-implant connection in removable denture.

    PubMed

    Melilli, Dario; Davì, Giuseppe; Messina, Pietro; Scardina, Giuseppe A

    2017-02-01

    When the patient cannot be rehabilitated with a fixed denture, or when he does not succeed in adapting to a traditional removable denture, a possible alternative solution consists in the use of a limited number of implants, placed in strategic positions in the arches of the patient, and subsequently connected to their residual teeth. The aim of this review is to evaluate the progress made on connections between teeth and implants in removable denture, to analyze their advantages and disadvantages and to compare the survival rate, both of the teeth and of the implants used as abutments, present in the various studies taken into examination, with the aim of being able to evaluate the effectiveness of this rehabilitative option. The concept of preserving residual teeth, even if these are unfavorably distributed, and inserting a minimum number of implants in strategic positions, thanks to which an area of favorable support for the denture can be created, seems reasonable; this will guarantee a better adaptation of the patient to the denture, as well as an improvement in the quality of life. The study of articles present in literature suggests that the survival rate of the implants in removable dentures, supported by teeth and implants through traditional systems of anchorage, appears to be quite high. However, further studies with a higher level of evidence, more representative test subjects and a longer follow-up period are necessary, in order to confirm the validity of this rehabilitative solution.

  3. Stress analysis at bone-implant interface of single- and two-implant-retained mandibular overdenture using three-dimensional finite element analysis.

    PubMed

    Lahoti, Krishnakumar; Pathrabe, Anup; Gade, Jaykumar

    2016-01-01

    The purpose of this research was to compare stress distribution on the bone between single implant-retained and two-implant-retained mandibular overdentures using three-dimensional (3D) finite element analysis. Two 3D finite element models were designed. The first model included single implant-supported mandibular overdenture placed in the midline of the mandible while the second model included two-implant-supported mandibular overdenture placed in the intra-foramen region, retained by ball attachment of the same diameter. The bone was modeled on the D2 bone depending on the classification given by Misch. A computed tomography scan of the mandible was used to model the bone by plotting the key points on the graph and generating the identical key points on the ANSYS Software (ANSYS, Inc., USA). The implant was modeled using appropriate dimensions as provided by the manufacturer. Stresses were calculated based on the von Mises criteria. Stresses produced in the hard bone (HB) and soft bone (SB) were higher in single implant-retained mandibular overdenture while stresses produced around the denture as well as implant were higher in two-implant-retained mandibular overdenture. Within the limitations of the study, it had been seen that stresses produced were the highest on HB and SB in single implant-retained mandibular overdenture while stresses produced across the denture as well as implant were the highest in two-implant-retained mandibular overdenture.

  4. Creating durable and esthetic gingival anatomy on a polyoxymethylene overdenture by using a chairside procedure.

    PubMed

    Login, Gary R

    2017-07-01

    Snap-On Smile (DenMat) appliances are tooth-borne overdentures used for a variety of temporary esthetic applications. However, their benefit can be limited in patients with high smile lines and altered gingival architecture because the teeth look too large. In this report, the author shows the chairside application of a silicone denture reline material used to recreate gingival anatomy on an overdenture fabricated from crystallized acetyl resin, the material used in a Snap-On Smile appliance. The author shows the gingival application's durability of greater than 2 years in a 78-year-old patient with multiple missing teeth and a severe mandibular ridge deformity. The author tested several commonly available denture reline materials and their bonding agents, which are known to bond to acrylic resin but have not been shown to bond to crystallized acetyl resin. The author observed no candida colonization during the 2-year reporting period. The author presents a simple and durable chairside technique to reproduce gingival tissue esthetically on Snap-On Smile appliances. Copyright © 2017 American Dental Association. Published by Elsevier Inc. All rights reserved.

  5. Palatal versus vestibular piezoelectric window osteotomy for maxillary sinus elevation: a comparative clinical study of two surgical techniques.

    PubMed

    Stübinger, Stefan; Saldamli, Belma; Seitz, Oliver; Sader, Robert; Landes, Constantin A

    2009-05-01

    The goal of this study was to compare the surgical advantages and disadvantages of a new palatal access osteotomy for sinus elevation with a conventional lateral approach. In 32 patients, either a palatal (n = 16) or a lateral (n = 16) osteotomy to the maxillary sinus was performed under local anesthesia. The palatal access included a circular paramarginal incision and elevation of a palatal mucosal flap based on a median pedicle. The lateral access was performed by vestibular standard incision and development of a mucoperiosteal flap with a vestibular and superior basis. For all osteotomies a piezoelectric device was used. The sinus cavity was augmented with synthetic nanostructured hydroxyapatite graft material. Intraoperative complications during both procedures were minimal and wound healing was uneventful. Membrane perforation occurred in 19% of the palatal group and in 19% of the lateral group. Soft tissue management of the palatal technique was superior to that of the lateral approach, because the vestibular anatomy was not altered and consequently no disharmonious soft tissue scarring and no postoperative swelling occurred. The palatal approach permitted higher postoperative comfort, especially for edentulous patients, because full dentures could be incorporated directly after surgery with almost perfect fit.

  6. Multidisciplinary approach to restoring anterior maxillary partial edentulous area using an IPS Empress 2 fixed partial denture: a clinical report.

    PubMed

    Dundar, Mine; Gungor, M Ali; Cal, Ebru

    2003-04-01

    Esthetics is a major concern during restoration of anterior partial edentulous areas. All-ceramic fixed partial dentures may provide better esthetics and biocompatibility in the restoration of anterior teeth. This clinic report describes a multidisciplinary approach and treatment procedures with an IPS Empress 2 fixed partial denture to restore missing anterior teeth.

  7. Digital Denture Fabrication in Pre- and Postdoctoral Education: A Survey of U.S. Dental Schools.

    PubMed

    Fernandez, Monica A; Nimmo, Arthur; Behar-Horenstein, Linda S

    2016-01-01

    To survey chairs of prosthodontics or restorative departments and program directors of postdoctoral prosthodontic programs in the United States regarding digital denture fabrication. The key objectives of the survey were to identify the current trends in complete denture fabrication using CAD/CAM technology and to determine how and to what extent this technique is taught and used in U.S. pre- and postdoctoral prosthodontic programs. An invitation to participate in an online survey was sent to 52 prosthodontics/restorative chairs of U.S. dental schools and to all of the 50 program directors of postdoctoral prosthodontics programs. A version of the survey with the same questions was sent to a national sample of prosthodontics/restorative chairs and program directors of postdoctoral prosthodontics. The 20-item survey took approximately 15 minutes to complete. Dependent samples paired t-test was run on items that were the same in both surveys. The response rate for the survey was 63% for department chairs and 44% for program directors. All respondents with the exception of one department chair were aware of CAD/CAM technology used for denture fabrication. More than half of the program directors (52.4%) compared to 12.1% of chairs have incorporated some aspects of CAD/CAM denture fabrication technology into their curriculum. When asked if the fabrication cost prevented introducing this technology in the predoctoral/postdoctoral curriculum, 52.4% of the department chairs affirmed this response compared to 12.1% of the program directors. There was a significant difference between groups when asked if they had incorporated the CAD/CAM denture fabrication technique into the postgraduate/predoctoral curriculum. Department chairs reported less usage of CAD/CAM technology. Only 12.1% of department chairs reported using some aspects of CAD/CAM technology in the predoctoral curriculum compared to 52.4% in the postdoctoral curriculum (F = 13.528, p ≤ 0.001). While this technology is used in four predoctoral clinics, none of the chairs reported including CAD/CAM denture fabrication in their preclinical complete denture courses. For the schools using the technology, 33.3% of postdoctoral and 30.3% of predoctoral programs use it to make a denture with a try-in step; however, 19% of the postdoctoral and 18.2% of predoctoral programs process the dentures without a try-in appointment. Slightly less than half (42.9%) of graduate programs are using the technology to make just the denture bases. Only a small proportion (10% or less) of the total number of dentures processed in post- and predoctoral programs are made using CAD/CAM technology. The proportion of postdoctoral programs that process cases using CAD/CAM technology was significantly higher than in predoctoral programs (F = 5.106, p ≤ 0.028). Many schools indicated that they are in a "trial phase" to evaluate the technique, especially at the predoctoral level. Also, 19% (n = 4) of postdoctoral and 15.2% (n = 5) of predoctoral respondents have created continuing education courses. Of postdoctoral programs, 38.1% (n = 8) plan to introduce this technology at some point in the near future (next 1 to 4 years); 27.3% of predoctoral programs plan to as well. All program directors and department chairs who participated in the survey are aware of this technology with the exception of one department chair. More than half of the program directors reported that they have incorporated this technology in their curricula compared to only 12% of department chairs. Currently, only 10% or less of complete denture cases are processed using the CAD/CAM technology, at either the post- or predoctoral levels. Both groups reported that the main use of this technology is for the fabrication of denture bases and for processing dentures including the try-in step. The majority of respondents in both groups indicated they plan to add digital denture fabrication into their curricula within the next 1 to 4 years. © 2015 by the American College of Prosthodontists.

  8. On-line soft sensing in upstream bioprocessing.

    PubMed

    Randek, Judit; Mandenius, Carl-Fredrik

    2018-02-01

    This review provides an overview and a critical discussion of novel possibilities of applying soft sensors for on-line monitoring and control of industrial bioprocesses. Focus is on bio-product formation in the upstream process but also the integration with other parts of the process is addressed. The term soft sensor is used for the combination of analytical hardware data (from sensors, analytical devices, instruments and actuators) with mathematical models that create new real-time information about the process. In particular, the review assesses these possibilities from an industrial perspective, including sensor performance, information value and production economy. The capabilities of existing analytical on-line techniques are scrutinized in view of their usefulness in soft sensor setups and in relation to typical needs in bioprocessing in general. The review concludes with specific recommendations for further development of soft sensors for the monitoring and control of upstream bioprocessing.

  9. [Principles of bone tissue structures interaction with full removable dentures fixed on intraosseous implantates modelling].

    PubMed

    Shashmurina, V R; Chumachenko, E N; Olesova, V N; Volozhin, A I

    2008-01-01

    Math modelling "removable dentures-implantate-bone" with size and density of bone tissue as variables was created. It allowed to study biomechanical bases of mandibular bone tissue structures interaction with full removable dentures of different constructions and fixed on intraosseous implantates. Analysis of the received data showed that in the majority of cases it was expedient to recommend 3 bearing (abutments) system of denture making. Rest on 4 and more implantates was appropriate for patients with reduced density of spongy bone and significant mandibular bone atrophy. 2 abutment system can be used in patients with high density of spongy bone and absence of mandibular bone atrophy.

  10. Contact allergy to denture materials in the burning mouth syndrome.

    PubMed

    van Joost, T; van Ulsen, J; van Loon, L A

    1988-02-01

    Several factors may be responsible for stomatitis in general and the burning mouth syndrome in particular. The results of patch testing are reported in 4 patients with burning mouth symptoms thought to be due to sensitization to denture material. 2 patients reacted to substances in Luxene dentures, but the allergens were not identified. In a 3rd patient, sensitization was found to monomeric methyl methacrylate. The other patient gave positive patch tests to epoxy resin (and bisphenol A), probably present in glue used for repair of dental plates. To obtain a complete diagnosis in cases of suspected contact stomatitis due to allergens in dentures, a reliable standard test series is required.

  11. Functional Impressions in Complete Denture and Overdenture Treatment

    PubMed Central

    Kršek, Hrvoje

    2015-01-01

    Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fabrication of complete dentures and overdentures, using standardized techniques and materials. An accurate functional impression together with other correctly performed clinical and laboratory procedures ensure good retention and stability of dentures, which is a precondition for restoring patients’ lost functions. PMID:27688385

  12. Nutritional status and oral status of the elderly with dementia: a 2-year study.

    PubMed

    Sadamori, Shinsuke; Hayashi, Syouji; Fujihara, Isao; Abekura, Hitoshi; Hamada, Taizo; Akagawa, Yasumasa

    2012-06-01

    To determine the relationship between denture wearing and nutritional status in the elderly with dementia. There could be a correlation between nutrition, oral health, dietary habits, patients' satisfaction, and their socio-economic status in the elderly, and the relationship between compromised oral status and nutritional status in the elderly with dementia. A 2-year follow-up study of 63 elderly Japanese women with and without dentures from a nursing home was undertaken to investigate their oral, physical and mental, and nutritional status. Each item for 2006 and 2008 in this study showed no significant difference between 2006 and 2008, except the calories/day. The elderly with dementia without complete dentures during the 2 years of the study only significantly decreased the mean of the calories/day. The calories/day of the elderly with dementia without dentures decreased after 2 years. Denture wearing for the elderly with dementia could be necessary to maintain a satisfactory intake of calories. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  13. In vitro evaluation of the flexural properties of All-on-Four provisional fixed denture base resin partially reinforced with fibers.

    PubMed

    Li, Bei Bei; Xu, Jia Bin; Cui, Hong Yan; Lin, Ye; Di, Ping

    2016-01-01

    The aim of this study was to assess the effects of partial carbon or glass fiber reinforcement on the flexural properties of All-on-Four provisional fixed denture base resin. The carbon or glass fibers were woven (3% by weight) together in three strands and twisted and tightened between the two abutments in a figure-of-"8" pattern. Four types of specimens were fabricated for the three-point loading test. The interface between the denture base resin and fibers was examined using scanning electron microscopy (SEM). Reinforcement with carbon or glass fibers between two abutments significantly increased the flexural strength and flexural modulus. SEM revealed relatively continuous contact between the fibers and acrylic resin. The addition of carbon or glass fibers between two abutments placed on All-on-Four provisional fixed denture base resin may be clinically effective in preventing All-on-Four denture fracture and can provide several advantages for clinical use.

  14. Antimicrobial activity of denture adhesive associated with Equisetum giganteum- and Punica granatum-enriched fractions against Candida albicans biofilms on acrylic resin surfaces.

    PubMed

    Almeida, Nara Ligia Martins; Saldanha, Luiz Leonardo; da Silva, Rafaela Alves; Pinke, Karen Henriette; da Costa, Eliane Ferraz; Porto, Vinicius Carvalho; Dokkedal, Anne Lígia; Lara, Vanessa Soares

    2018-01-01

    Candida biofilms adhere to the internal surface of removable dentures, which is an etiological factor in the pathogenesis of denture stomatitis (DS). Adhesive materials are used at the base of maxillary complete dentures to improve their retention and chewing qualities. This article reports the antimicrobial activity of the enriched fractions of Equisetum giganteum and Punica granatum incorporated into a denture adhesive against C. albicans biofilm. The biofilms were induced on the surface of heat-cured acrylic resin specimens that were previously treated with a mixture of adhesive/herb extracts. The antimicrobial activity was evaluated by CFU counts, XTT reduction, and SEM and CLSM analysis. Both herb extracts amplified the anti-biofilm action of the adhesive on the acrylic resin by up to 12 h. Therefore, when these extracts were combined with COREGA®, they played a collaborative and innovative role in biofilm control and can be considered alternatives for temporary use in the treatment and/or prevention of DS.

  15. Complete denture tooth arrangement technology driven by a reconfigurable rule.

    PubMed

    Dai, Ning; Yu, Xiaoling; Fan, Qilei; Yuan, Fulai; Liu, Lele; Sun, Yuchun

    2018-01-01

    The conventional technique for the fabrication of complete dentures is complex, with a long fabrication process and difficult-to-control restoration quality. In recent years, digital complete denture design has become a research focus. Digital complete denture tooth arrangement is a challenging issue that is difficult to efficiently implement under the constraints of complex tooth arrangement rules and the patient's individualized functional aesthetics. The present study proposes a complete denture automatic tooth arrangement method driven by a reconfigurable rule; it uses four typical operators, including a position operator, a scaling operator, a posture operator, and a contact operator, to establish the constraint mapping association between the teeth and the constraint set of the individual patient. By using the process reorganization of different constraint operators, this method can flexibly implement different clinical tooth arrangement rules. When combined with a virtual occlusion algorithm based on progressive iterative Laplacian deformation, the proposed method can achieve automatic and individual tooth arrangement. Finally, the experimental results verify that the proposed method is flexible and efficient.

  16. [Maintenance and the clinical evaluation of periodontal patients in Konus-Telescope denture].

    PubMed

    Shin, K; Araki, H; Maeda, S; Miyata, T; Ikeda, K

    1989-12-01

    In order to assess by periodontal evaluation the changes that might occur with time in the abutment teeth and periodontal tissues when Konus-Telescope dentures are used as that final treatment of periodontal disease, the dentures (15 units) were placed in 13 patients with missing tooth and periodontal disease and findings at the time of denture placement and 30 months after the placement were compared. The number of cases that exhibited significant changes in hygiene level, tissue inflammation and periodontal pocket depth of the abutment teeth after 30 months was very small, while as many as 85.2% of the abutment teeth showed decrease in tooth mobility. Increase in tooth mobility was not detected in any of the cases. In addition, X-ray examination revealed tendencies toward improvement of the periodontal ligament and remission of alveolar bone resorption in many of the cases. These results suggest that Konus-Telescope denture is highly offers protection of the residual periodontal tissues through its secondary splint action.

  17. Fracture Surface Analysis of Clinically Failed Fixed Partial Dentures

    PubMed Central

    Taskonak, B.; Mecholsky, J.J.; Anusavice, K.J.

    2008-01-01

    Ceramic systems have limited long-term fracture resistance, especially when they are used in posterior areas or for fixed partial dentures. The objective of this study was to determine the site of crack initiation and the causes of fracture of clinically failed ceramic fixed partial dentures. Six Empress 2® lithia-disilicate (Li2O·2SiO2)-based veneered bridges and 7 experimental lithia-disilicate-based non-veneered ceramic bridges were retrieved and analyzed. Fractography and fracture mechanics methods were used to estimate the stresses at failure in 6 bridges (50%) whose fracture initiated from the occlusal surface of the connectors. Fracture of 1 non-veneered bridge (8%) initiated within the gingival surface of the connector. Three veneered bridges fractured within the veneer layers. Failure stresses of the all-core fixed partial dentures ranged from 107 to 161 MPa. Failure stresses of the veneered fixed partial dentures ranged from 19 to 68 MPa. We conclude that fracture initiation sites are controlled primarily by contact damage. PMID:16498078

  18. [The effect of denture base resins coated with antibacterial coating on water sorption, solubility and monomer elution].

    PubMed

    Yang, Yang; Gong, Hai-Huan; Song, Ai-Yang; Feng, Dan; Jin, Jie; Zhu, Song

    2015-02-01

    To determine the influence of denture base resins coated with antibacterial coating on water sorption, solubility and monomer elution. The values of water sorption and solubility were measured according to YY 0270-2003 and gas chromatography was used to examine the leachability of 4 commercially available heat-cured acrylic resins between experimental group and control group. Degree of crosslinking of the experimental heat-cured acrylic denture bases we remeasured by soxhlet extraction method. The data was analyzed by 17.0 software package. The values of water sorption, solubility and monomer elution of experimental group were lower compared to the control group. Degree of crosslinking of Heraeus reins was the highest among the experimental heat-cured acrylic denture bases. There is a same trend among water sorption, degree of crosslinking and the monomer elution. When the degree of crosslinking increases, the values of water sorption and monomer elution decrease. Antibacterial coating can improve the comprehensive properties of the denture base resins.

  19. The effect of mechanical and chemical polishing techniques on the surface roughness of denture base acrylic resins.

    PubMed

    Al-Rifaiy, Mohammed Q

    2010-01-01

    Smooth polished surface of dental prostheses is important to prevent bacterial colonization and plaque accumulation. The acrylic base of prosthodontic appliances needs to be adjusted by grinding which often alters the surface of the denture base. It is therefore important to know how different polishing techniques affect surface roughness of acrylic resin. The aim of this study was to evaluate the effect of mechanical polishing (MP) and chemical polishing (CP) on the surface roughness of heat cured (HC) and auto cured (AC) denture base acrylic resins. Sixty acrylic resin specimens (30 × 15 × 3 mm) were made for each of the two types of acrylic resins. Thirty HC specimens received mechanical conventional lathe polishing using cone with pumice slurry and soft brush with chalk powder. The other thirty HC specimens received chemical polishing by immersing in methyl-methacrylate monomer heated to 75 °C ± 1 °C for 10 s. The sixty AC specimens received mechanical and chemical polishing in the same manner. Surface roughness was measured using surface analyzing instrument in microns. The data were statistically analyzed by two-way analysis of variance (ANOVA) followed by post hoc Tukey's test (α = 0.05). THE SURFACE ROUGHNESS MEAN IN MICRONS IN ORDER OF DECREASING VALUES WERE: CP-HC: 1.4132 μm; CP-AC: 1.3494 μm; MP-AC: 0.7364 μm and MP-HC: 0.6333 μm. Two-way ANOVA revealed that the MP-HC was significantly different from CP-HC and CP-AC (P < 0.05). The MP-AC is also significantly different from CP-HC and CP-AC (P < 0.05). There was no significant difference between MP and CP of HC and AC acrylic resin groups. It can be concluded that MP produced significantly smoother surfaces than CP. The surface roughness obtained by MP was not influenced by acrylic resin type where as this was not true for CP.

  20. Impact of Packing and Processing Technique on Mechanical Properties of Acrylic Denture Base Materials

    PubMed Central

    Nejatian, Touraj; Sefat, Farshid; Johnson, Tony

    2015-01-01

    The fracture resistance of polymethylmethacrylate (PMMA) as the most popular denture base material is not satisfactory. Different factors can be involved in denture fracture. Among them, flexural fatigue and impact are the most common failure mechanisms of an acrylic denture base. It has been shown that there is a correlation between the static strength and fatigue life of composite resins. Therefore, the transverse strength of the denture base materials can be an important indicator of their service life. In order to improve the fracture resistance of PMMA, extensive studies have been carried out; however, only a few promising results were achieved, which are limited to some mechanical properties of PMMA at the cost of other properties. This study aimed at optimizing the packing and processing condition of heat-cured PMMA as a denture base resin in order to improve its biaxial flexural strength (BFS). The results showed that the plain type of resin with a powder/monomer ratio of 2.5:1 or less, packed conventionally and cured in a water bath for 2 h at 95 °C provides the highest BFS. Also, it was found that the performance of the dry heat processor is inconsistent with the number of flasks being loaded.

  1. Nanoindentation and surface roughness profilometry of poly methyl methacrylate denture base materials.

    PubMed

    Zafar, Muhammad Sohail; Ahmed, Naseer

    2014-01-01

    Polymers have a wide range of applications in dentistry. Poly methyl methacrylate (PMMA) is the most popular for making orthodontic retainers, dentures as well as synthetic teeth. Prior to clinical applications, the appliances are polished in the dental laboratory to achieve smooth, polished and comfortable surfaces. The objective of this study was to analyze the surface roughness profiles of PMMA dentures polished using two different approaches. In addition, the effects of ultrasonication and sandblasting were also evaluated on the fitting surface of PMMA dentures. This was an in vitro study using non-contact mode surface roughness profilometer and nano-indenter. Samples were polished using two different techniques (Standard and modified). Both cold cure and heat cure PMMA denture surfaces were evaluated for roughness, nanohardness and elastic modulus. The absolute hardness was recorded 297.72±19.04 MPa and 229.93±18.53 MPa for heat cured PMMA and cold cured PMMA. Manufactured acrylic teeth were harder (319.20±12.58 MPa) with an elastic modulus of (4.34±1.86 GPa). Modified polishing techniques (group 3) produced smoother surface. It was concluded that elastic moduli of acrylic tooth and heat cure PMMA is not very different. Surface treatments such as ultrasonication or sandblasting do not affect the roughness profiles of denture fitting surfaces.

  2. Alkaline Peroxides Versus Sodium Hypochlorite for Removing Denture Biofilm: a Crossover Randomized Trial.

    PubMed

    Peracini, Amanda; Regis, Rômulo Rocha; Souza, Raphael Freitas de; Pagnano, Valéria Oliveira; Silva, Cláudia Helena Lovato da; Paranhos, Helena de Freitas Oliveira

    2016-01-01

    This study evaluated the efficacy of cleanser solutions on denture biofilm removal by a crossover randomized clinical trial. Thirty two edentulous patients were instructed to brush their dentures (specific brush and liquid soap) three times a day (after breakfast, lunch and dinner) and to soak them (≥ 8 h) in: (C) control -water; (AP): alkaline peroxide; or (SH) 0.5% sodium hypochlorite. Each solution was used for 21 days (three cycles of 7 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 - Sony). Areas (total and stained biofilm) were measured (Image Tool software) and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. Data were compared by means of generalized estimating equation (α=5%) and multiple comparisons (Bonferroni; α=1.67%). Immersion in SH reduced biofilm (%) (8.3 ± 13.3B) compared to C (18.2 ± 14.9A) and AP (18.2 ± 16.6A). The 0.5% sodium hypochlorite solution was the most efficacious for biofilm removal. Alkaline peroxides may not lead to further biofilm removal in patients with adequate denture maintenance habits.

  3. Mechanical properties of injection-molded thermoplastic denture base resins.

    PubMed

    Hamanaka, Ippei; Takahashi, Yutaka; Shimizu, Hiroshi

    2011-03-01

    To investigate the mechanical properties of injection-molded thermoplastic denture base resins. Four injection-molded thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were used in this study. The flexural strength at the proportional limit (FS-PL), the elastic modulus, and the Charpy impact strength of the denture base resins were measured according to International Organization for Standardization (ISO) 1567 and ISO 1567:1999/Amd 1:2003. The descending order of the FS-PL was: conventional PMMA > polyethylene terephthalate, polycarbonate > two polyamides. The descending order of the elastic moduli was: conventional PMMA > polycarbonate > polyethylene terephthalate > two polyamides. The descending order of the Charpy impact strength was: polyamide (Nylon PACM12) > polycarbonate > polyamide (Nylon 12), polyethylene terephthalate > conventional PMMA. All of the injection-molded thermoplastic resins had significantly lower FS-PL, lower elastic moduli, and higher or similar impact strength compared to the conventional PMMA. The polyamide denture base resins had low FS-PL and low elastic moduli; one of them possessed very high impact strength, and the other had low impact strength. The polyethylene terephthalate denture base resin showed a moderately high FS-PL, moderate elastic modulus, and low impact strength. The polycarbonate denture base resin had a moderately high FS-PL, moderately high elastic modulus, and moderate impact strength.

  4. Evaluation of Sensibility Threshold for Interocclusal Thickness of Patients Wearing Complete Dentures

    PubMed Central

    Shala, Kujtim Sh.; Ahmedi, Enis F.; Tmava-Dragusha, Arlinda

    2017-01-01

    Objective The aim of this study was to evaluate sensibility threshold for interocclusal thickness in experienced and nonexperienced denture wearers after the insertion of new complete dentures. Materials and Methods A total of 88 patients with complete dentures have participated in this study. The research was divided into two experimental groups, compared with the previous experience prosthetic dental treatment. The sensibility threshold for interocclusal thickness was measured with metal foil with 8 μm thickness and width of 8 mm, placed between the upper and lower incisor region. Statistical analysis was performed using standard software package BMDP (biomedical statistical package). Results Results suggest that time of measurement affects the average values of the sensibility threshold for interocclusal thickness (F = 242.68, p = 0.0000). Gender appeared to be a significant factor when it interacted with time measurement resulting in differences in sensibility threshold for interocclusal thickness (gender: F = 9.84, p = 0.018; F = 4.83, p = 0.0003). Conclusion The sensibility threshold for interocclusal thickness was the most important functional adaptation in patient with complete dentures. A unique trait of this indicator is the progressive reduction of initial values and a tendency to reestablish the stationary state in the fifteenth week after dentures is taken off. PMID:28702055

  5. Rechargeable anticandidal denture material with sustained release in saliva

    PubMed Central

    Malakhov, Andrey; Wen, Jianchuan; Zhang, Bin-Xian; Wang, Hanzhou; Geng, Hui; Chen, Xiao-Dong; Sun, Yuyu; Yeh, Chih-Ko

    2016-01-01

    Objective Candida-induced denture stomatitis is a common debilitating problem among denture wearers. Previously, we described the fabrication of a new denture material that released antifungal drugs when immersed in phosphate buffered saline. Here, we use more clinically relevant immersion conditions (human saliva; 37°C) and measure miconazole release and bioactivity. Materials and Methods Disks were prepared by grafting PNVP [poly(N-vinyl-2-pyrrolidinone)] onto PMMA [poly(methylmethacrylate)] using plasma initiation (PMMA-g-PNVP) and then loaded with miconazole. Drug-loaded disks were immersed in 10–100% human saliva (1–30 days). Miconazole release was measured and then tested for bioactivity versus miconazole-sensitive and -resistant Candida isolates. Results HPLC was used to quantify miconazole levels in saliva. Miconazole-loaded disks released antifungal drug for up to 30 days. Higher drug release was found with higher concentrations of saliva and, interestingly, miconazole solubility was increased with higher saliva concentrations. The released miconazole retained its anticandidal activity. After immersion, the residual miconazole could be quenched and the disks recharged. Freshly recharged disks displayed the same release kinetics and bioactivity as the original disks. Quenched disks could also be charged with chlorhexidine that displayed anticandidal activity. Conclusions These results suggest that PMMA-g-PNVP is a promising new denture material for long-term management of denture stomatitis. PMID:26855200

  6. [Application of individual light-curing resin tray as edge plastic material in complete denture modulo].

    PubMed

    Chai, Mei; Tang, Xuyan; Liang, Guangku

    2015-12-01

    To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo.
 A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures.
 There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor.
 Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.

  7. Telescopic Overdenture: A Case Report

    PubMed Central

    Shruthi, C. S.; Poojya, R.; Ram, Swati; Anupama

    2017-01-01

    Patient: This report describes the case of a 68 year old female patient who presented with the chief complaint of difficulty in chewing and poor aesthetics due to missing teeth. The patient was interested in saving the remaining natural teeth and desired minimal tissue coverage from the prosthesis. After consideration of all the factors involved, it was deemed advisable to resort to a palate free maxillary telescopic complete denture and a mandibular removable partial denture. Discussion: Considering the age of the patient and the cost involved, implant supported prosthesis was ruled out as a treatment option for the patient. A telescopic denture was chosen as a favourable treatment option since it overcomes many of the problems posed by conventional complete dentures like progressive bone loss, lower stability and retention, loss of periodontal proprioception and low masticatory efficiency. It also provides minimal tissue coverage and better distribution of forces. Evaluation of occlusion, esthetics, phonetics and comfort after 24 hours, 1 week and 1 month of treatment showed that the patient was happy with the prosthesis and was able to speak and chew well. Conclusion: Telescopic overdentures have better retention and stability as compared to conventional complete dentures. They improve the chewing efficiency, patient comfort and also decrease the alveolar bone resorption. As such they are an excellent alternative to conventional complete denture treatment. PMID:28533736

  8. Biting and chewing in overdentures, full dentures, and natural dentitions.

    PubMed

    Fontijn-Tekamp, F A; Slagter, A P; Van Der Bilt, A; Van 'T Hof, M A; Witter, D J; Kalk, W; Jansen, J A

    2000-07-01

    It has been suggested that the provision of dental implants can improve the oral function of subjects with severely resorbed mandibles, possibly restoring function to the level experienced by satisfied wearers of conventional complete dentures. Nevertheless, a quantitative comparison has never been made and can be drawn from the literature only with difficulty, since studies differ greatly in methodology. To make such a comparison, we measured bite force and chewing efficiency by using identical methods in subjects with overdentures, complete full dentures, and natural dentitions. Our results indicated that bite forces achieved with overdentures on dental implants were between those achieved with artificial and natural dentitions. Chewing efficiency was significantly greater than that of subjects with full dentures (low mandible), but was still lower than that of subjects with full dentures (high mandible) and overdentures on bare roots. Differences in the height of the mandible revealed significant differences in chewing efficiency between the two full-denture groups. Furthermore, subjects with a shortened dental arch exerted bite forces similar to those of subjects with a complete-natural dentition, but their chewing efficiency was limited due to the reduced occlusal area. For all groups combined, a significant correlation was found between maximum bite force and chewing efficiency. Nearly half of the variation in chewing efficiency was explained by bite force alone.

  9. Telescopic Overdenture: A Case Report.

    PubMed

    Shruthi, C S; Poojya, R; Ram, Swati; Anupama

    2017-03-01

    This report describes the case of a 68 year old female patient who presented with the chief complaint of difficulty in chewing and poor aesthetics due to missing teeth. The patient was interested in saving the remaining natural teeth and desired minimal tissue coverage from the prosthesis. After consideration of all the factors involved, it was deemed advisable to resort to a palate free maxillary telescopic complete denture and a mandibular removable partial denture. Considering the age of the patient and the cost involved, implant supported prosthesis was ruled out as a treatment option for the patient. A telescopic denture was chosen as a favourable treatment option since it overcomes many of the problems posed by conventional complete dentures like progressive bone loss, lower stability and retention, loss of periodontal proprioception and low masticatory efficiency. It also provides minimal tissue coverage and better distribution of forces. Evaluation of occlusion, esthetics, phonetics and comfort after 24 hours, 1 week and 1 month of treatment showed that the patient was happy with the prosthesis and was able to speak and chew well. Telescopic overdentures have better retention and stability as compared to conventional complete dentures. They improve the chewing efficiency, patient comfort and also decrease the alveolar bone resorption. As such they are an excellent alternative to conventional complete denture treatment.

  10. Comparing masticatory performance between dentate individuals and removable denture wearers

    NASA Astrophysics Data System (ADS)

    Nasseri, G.; Dermawan, T.; Marito, P.; Ariani, N.; Gita, F.; Ono, T.; Kusdhany, L.

    2017-08-01

    Tooth loss replacement with dental prostheses aims to restore stomatognathic function, including masticatory performance. Masticatory performance is one of the factors that affect stomatognathic function and health in general. The aim of this study was to compare the masticatory performance of fully dentate subjects and removable denture wearers and determine which method is most suitable, whether using color-changeable chewing gum or gummy jelly. Subjects were classified into two groups: fully dentate (n=10) and removable denture groups (n=10). Masticatory performance was measured using color-changeable chewing gum with 30, 45 and 60 strokes and gummy jelly with 10, 20 and 30 strokes. A Mann-Whitney analysis was done to compare the masticatory performance of the fully dentate and removable denture groups. There was a significant difference (p<0.05) in masticatory performance between the two groups, both with chewing gum and gummy jelly. Spearman’s correlation was used to analyze the correlation between the chewing gum and gummy jelly measurements. Statistically, a significant correlation (P<0.05) was found between the color-changeable chewing gum and gummy jelly. A removable denture does improve masticatory performance, but it is not able to fully restore masticatory performance comparable to dentate individuals. Color-changeable chewing gum and gummy jelly can differentiate masticatory performance in fully dentate and removable denture groups.

  11. Implant overdentures: dental students' performance in fabrication, denture quality, and patient satisfaction.

    PubMed

    Aragon, Cecilia E; Cornacchio, Angelica Lee Petrina; Ibarra, Lilia Marcela; Saad, Muhammed N; Zibrowski, Elaine

    2010-09-01

    The purpose of this study was to evaluate dental students' performance when fabricating a mandibular two-implant overdenture (OD) as compared to conventional dentures (CD) and to determine if these prostheses were successful. Twenty students and twenty patients were divided into two groups: complete denture group (CDG) and maxillary denture and two-implant OD group (ODG). Students' progress was evaluated at each appointment as they were given a clinical assessment score (CAS), which varied from 1 (unacceptable, needs to repeat procedure) to 4 (acceptable, no errors). The success of the prosthesis was evaluated by the patients using a visual analog scale (VAS) and an expert (a prosthodontist) using a denture quality assessment (DQA) form. Performance for both groups was not statistically different across all eight appointments (CDG 3.16 versus ODG 3.25; p=0.46). Patients with ODs reported greater stability with their dentures (p=0.048) and greater ability to chew than patients with CDs (p=0.03). There were no differences between the groups in terms of expert appraisal (ODG 71.1 versus CDG 67.5; p=0.59). The performance of dental students when fabricating a two-implant OD is thus not different from that of a CD. Students can successfully fabricate a two-implant OD as perceived by both patients and prosthodontists.

  12. Edentulous patients' knowledge of dental hygiene and care of prostheses.

    PubMed

    de Castellucci Barbosa, Luciano; Ferreira, Manoela Rejane Maia; de Carvalho Calabrich, Carolina Freire; Viana, Aline Cavalcanti; de Lemos, Maria Catarina Lavigne; Lauria, Roberta Andrade

    2008-06-01

    The aim of this study was to analyse denture users' oral care habits with regard to the use of their prostheses. Rehabilitative treatment is only successful when patients are motivated and aware of correct prosthesis use and hygiene. Questionnaires were distributed to 150 complete denture users at the Federal University of Bahia School of Dentistry, the Esmeralda Natividade Health Center, the Bahian Science Development Foundation and a Salvador nursing home. The questionnaire included information on gender, age, length of prosthesis use, cleaning methods and materials, etc. The data were analysed using EpiInfo version 6 software. The chi-squared test was used for statistical analysis, with a significance level of 5%. Questionnaire results showed that 78% of the subjects, with an average age of 67.3 years, had used the same complete denture for over 5 years. 64% slept with their prostheses and 44% removed them from the mouth only for cleaning. None of the patients interviewed knew anything about brushes designed specifically for complete dentures. 37.3% had a restricted diet and 44% believed that a complete denture would last for more than 10 years. Within the limitations of this study, it was concluded that the edentulous patients surveyed had limited awareness of prosthetic hygiene and long-term oral care despite extended periods of denture use.

  13. Photoelastic analysis of mandibular full-arch implant-supported fixed dentures made with different bar materials and manufacturing techniques.

    PubMed

    Zaparolli, Danilo; Peixoto, Raniel Fernandes; Pupim, Denise; Macedo, Ana Paula; Toniollo, Marcelo Bighetti; Mattos, Maria da Glória Chiarello de

    2017-12-01

    To compare the stress distribution of mandibular full dentures supported with implants according to the bar materials and manufacturing techniques using a qualitative photoelastic analysis. An acrylic master model simulating the mandibular arch was fabricated with four Morse taper implant analogs of 4.5×6mm. Four different bars were manufactured according to different material and techniques: fiber-reinforced resin (G1, Trinia, CAD/CAM), commercially pure titanium (G2, cpTi, CAD/CAM), cobalt‑chromium (G3, Co-Cr, CAD/CAM) and cobalt‑chromium (G4, Co-Cr, conventional cast). Standard clinical and laboratory procedures were used by an experienced dental technician to fabricate 4 mandibular implant-supported dentures. The photoelastic model was created based on the acrylic master model. A load simulation (150N) was performed in total occlusion against the antagonist. Dentures with fiber-reinforced resin bar (G1) exhibited better stress distribution. Dentures with machined Co-Cr bar (G3) exhibited the worst standard of stress distribution, with an overload on the distal part of the posteriors implants, followed by dentures with cast Co-Cr bar (G4) and machined cpTi bar (G2). The fiber-reinforced resin bar exhibited an adequate stress distribution and can serve as a viable alternative for oral rehabilitation with mandibular full dentures supported with implants. Moreover, the use of the G1 group offered advantages including reduced weight and less possible overload to the implants components, leading to the preservation of the support structure. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up.

    PubMed

    Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M

    2016-01-01

    In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan-Meier method. None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study.

  15. [Foreign dentures and dental tourism--willingness-to-pay and factors influencing the demand for foreign dental prosthesis in Germany].

    PubMed

    Köberlein, J; Klingenberger, D

    2011-07-01

    With the progressive realisation of the single European market, public interest has been directed towards cross-border healthcare services to an increasing extent. More and more dentures are being imported into Germany from foreign countries. Furthermore, patients are becoming ever more mobile, travelling to other countries to receive prosthetic treatment from dentists. The objective of this evaluation was to determine by means of a dedicated questionnaire the patients' individual preferences for foreign dentures and the potential savings. 1 368 individuals between the ages of 30 and 75 years were interviewed within a representative omnibus survey. The evaluation of the individual willingness-to-pay included 4 treatment scenarios, which were assessed by the participants in a "bidding game". Participants could choose between a "crown scenario" and an "implant scenario", both with the subcategories "foreign dentures" and "dental tourism". The direct comparison revealed a preference for the "foreign dentures" option over "dental tourism". Average willingness-to-pay for the dental tourism option in the crown scenario was calculated as 80 Euro, and in the implant scenario as 280 Euro less in comparison with the willingness-to-pay for the foreign dentures option. The willingness to switch to a less expensive dentist was one of the main determinants in the causal explanation for the variance in willingness-to-pay. Quality proved to be the decisive criterion and was indicated by 92.4% participants. A lower price for dentures played a subordinate role and was only stated as the decisive factor by 31.1% participants. In conclusion, the results clearly indicate that the decision for or against foreign dentures and the extent of willingness-to-pay depends on a range of criteria, of which "price" is only one and not the decisive factor. © Georg Thieme Verlag KG Stuttgart · New York.

  16. A multispecies probiotic reduces oral Candida colonization in denture wearers.

    PubMed

    Ishikawa, Karin H; Mayer, Marcia P A; Miyazima, Tatiana Y; Matsubara, Victor H; Silva, Eriques G; Paula, Claudete R; Campos, Tomie T; Nakamae, Atlas E M

    2015-04-01

    The prevalence of Candida infections has been rising with an increasingly aging population and a larger population of immunocompromised individuals. The use of probiotics may be an alternative approach to antifungal agents in the prevention and treatment of oral candidiasis. This study aimed to evaluate the short-term effect of probiotics in reducing the infection level of oral Candida in candidiasis-asymptomatic elderly denture wearers. In a double-blind randomized study, 59 denture wearers harboring Candida spp. in the oral cavity with no clinical symptoms were allocated into two groups: probiotic and placebo. All patients were instructed to clean the denture daily. The probiotic group poured a capsule containing lyophilized Lactobacillus rhamnosus HS111, Lactobacillus acidophillus HS101, and Bifidobacterium bifidum daily on the palatal surface of the maxillary denture, whereas the placebo group was submitted to the same regimen using placebo capsules. Candida spp. infection levels were evaluated in palate mucosa samples obtained before and after a 5-week experimental period. All patients harbored Candida in the palate mucosa at baseline. Fifty-five individuals completed the experimental period. The detection rate of Candida spp. was 92.0% in the placebo group after the experimental period, whereas it was reduced to 16.7% in the probiotic group. The reduction promoted by the probiotic regimen was independent of baseline characteristics such as Candida infection level and colonizing species, age of denture, and other variables. The probiotic product was effective in reducing the colonization of the oral cavity with Candida in candidiasis-asymptomatic elderly denture wearers, suggesting that this multispecies probiotic could be used to prevent oral candidiasis. Colonization of oral surfaces by Candida is considered a risk factor for invasive fungal infections. The use of a product with L. rhamnosus, L. acidophilus, and B. bifidum may represent an alternative treatment for reduction of Candida infections in elderly denture wearers. © 2014 by the American College of Prosthodontists.

  17. Does a mandibular overdenture improve nutrient intake and markers of nutritional status better than conventional complete denture? A systematic review and meta-analysis

    PubMed Central

    Yamazaki, Toru; Martiniuk, Alexandra LC; Irie, Koichiro; Sokejima, Shigeru; Lee, Crystal Man Ying

    2016-01-01

    Objectives The need for denture treatment in public health will increase as the population ages. However, the impact of dentures on nutrition, particularly overdenture treatment, remains unclear although the physical and psychological effects are known. We investigated whether treatment with a mandibular implant supported overdenture improves nutrient intake and markers of nutritional status better than a conventional complete denture in edentulous patients. Design Systematic review and meta-analysis. Methods Medline, EMBASE and the Cochrane Central Register of Controlled Trials were searched for eligible studies published up to April 2016. We included studies which compared the treatment effect of an overdenture to conventional denture on nutrition, in which primary outcomes included changes in intake of macronutrients and/or micronutrients and/or indicators of nutritional status. Two reviewers independently evaluated eligible studies and assessed the risk of bias. We used a fixed effects model to estimate the weighted mean difference (WMD) and 95% CI for change in body mass index (BMI), albumin and serum vitamin B12 between overdenture and conventional denture 6 months after treatment. Results Of 108 eligible studies, 8 studies involving 901 participants were included in the narrative appraisal. Four studies reported changes in markers of nutritional status and nutrient intake after treatment with a prosthetic, regardless of type. In a meta-analysis of 322 participants aged 65 years or older from three studies, pooled analysis suggested no significant difference in change in BMI between an overdenture and conventional denture 6 months after treatment (WMD=−0.18 kg/m2 (95% CI −0.52 to 0.16)), and no significant difference in change in albumin or vitamin B12 between the two treatments. Conclusions The modifying effect of overdenture treatment on nutritional status might be limited. Further studies are needed to evaluate the effectiveness and efficacy of denture treatments. PMID:27489156

  18. Quantity and quality analysis of dental prosthodontics among retirement age residents from nursing homes in different regions of Latvia and retirement age patients from dental clinic in Riga.

    PubMed

    Vidzis, Aldis; Cema, Ingrida; Brinkmane, Anda; Krasta, Ingrida; Broka, Kristine

    2012-01-01

    The quality of life is closely related with condition of oral health, influence of subjective factors on the whole human body and patients perception of their oral health. In spite of the fact that the most part of Latvian retirement age residents use low-quality dentures and assess them satisfactory, these patients often have problems associated with quality of dentures. The aim of the present study was to evaluate oral health status, prosthodontics indicators and patients satisfaction with oral health among Latvian retirement age residents. There were examined 465 retirement age volunteers (170 men and 295 women), 116 of them in dental clinic Sandent (Riga, 24.9% - control group), 137 (29.5%) in nursing homes in Zemgale and 212 (45.6%) in nursing homes in Kurzeme (Zemgale and Kurzeme are districts of Latvia). There were assessed quantity of prosthodontics among patients with partial defects of dental arches, there were estimated quality of dentures and patients satisfaction with existing prosthodontics. Oral health indicators among Latvian retirement age population are better than the same indicators among elderly residents of nursing homes. Among nursing homes residents with partial edentulousness in most of cases in oral cavities remained only few residual teeth which needed treatment. Removable and fixed dental prostheses used by nursing homes residents do not meet denture's quality criteria. Self-evaluation of dentures quality among retirement age residents of nursing homes is better and not correspond with existing dentures quality. In Latvia the quantity of prosthodontics in respect of partial removable dentures among the retired who regularly visit a dentist does not significantly differ from European retirement age population's dental prosthodontics quantity. Dental prosthodontics indicators of residents of nursing homes in Latvia are unsatisfactory (p<0.001). In retirement age population self-evaluation with quality of dentures is higher than actually existing.

  19. Pathogenic characteristics of Candida albicans isolated from oral cavities of denture wearers and cancer patients wearing oral prostheses.

    PubMed

    Mothibe, J V; Patel, M

    2017-09-01

    Candida albicans cause opportunistic infections including oral candidiasis in immunocompromised patients. It has an ability to cause infection due to its virulence factors. This study investigated the pathogenic characteristics of C. albicans isolated from the oral cavities of healthy subjects and two vulnerable groups, denture wearers and cancer patients wearing oral prostheses. Oral rinse samples were collected and cultured for the quantitative and qualitative analysis of Candida. Twenty strains of C. albicans isolated from the healthy individuals and denture wearers and, 14 strains isolated from the cancer patients were selected and their pathogenic characteristics were measured. The results of the study groups were compared using a Scheffe test for pairwise comparison and a chi square test. Denture wearer and cancer patients with prostheses carried significantly higher number (p < 0.01) and a variety of Candida than the normal individuals. Denture wearer and cancer patients carried several Candida species. The adherence abilities (p = 0.01) as well as phospholipase (p < 0.01) and proteinase (p = 0.03) production were significantly higher in the strains from denture wearers. In addition, high number of isolates from the denture wearers produced phospholipase and proteinase (85% and 80% respectively) compared to the strains from normal subjects (25% and 60% respectively). Only the germ tube formation and adherence ability were significantly higher in the strains from the cancer patients with prostheses (p = 0.05 and p < 0.01 respectively). In conclusion, during the commensal state, the increased expression of virulence factors in the denture wearers suggests the readiness of these strains to cause infection in this group. The high number of C. albicans and their increased adherence ability in the two study groups suggest that hygiene of oral cavity and prostheses is important in the prevention of colonization of Candida and the development of oral candidiasis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Determination of the effective anticandidal concentration of denture cleanser tablets on some denture base resins

    PubMed Central

    Hayran, Yeliz; Sarikaya, Işıl; Aydin, Ali; Tekin, Yadel Hazır

    2018-01-01

    Abstract Objective Although the effectiveness of chemical cleansing against Candida albicans biofilm has been shown, the effective concentration of denture cleanser tablets has not been studied. The aim of this study was to assess the effect of three denture materials against Candida albicans biofilm and to determine effective concentrations of denture cleanser tablets. Material and methods The surface-roughness of Acron-hi™, QC-20™ and Deflex™ (n=45 per resin) resins was standardized by using a profilometer and their contact angle or surface free energy was calculated. C. albicans biofilm was formed on all three resins and were treated with Polident 3 min™, Corega™ and Fittydent™ cleanser solutions at various concentrations and both resin-biofilm and cleanser-biofilm interest were determined by using a MTT protocol according to the European Committee on Antimicrobial Susceptibility Testing's antifungal susceptibility testing (AFST-EUCAST). Scanning electron microscopy was used to compare the efficacy of different resin materials against C. albicans biofilm. Anticandidal activity and surface free energy statistical parameters were calculated by using 3-way and 1-way ANOVA, respectively (p<0.05). Results Polident 3 min™ and Corega™ tablets significantly inhibited (p<0.05) the proliferation of C. albicans against all denture resins at 27-37 mg/mL. Scanning electron microscopy results indicated that there was no significant difference among resin specimens regarding biofilm formation on dentures. We failed to find a significant relationship between surface free energy and the anticandidal effect of resin types. However, the polarity value of the resins was statistically associated with their anticandidal activity. Conclusions The polarity of the resins, the concentrations of tablets and the chemical content of the cleanser may directly affect C. albicans biofilm formations. Polident 3 min™ and Corega™ tablets should be suggested for patients who use any denture resin types, whereas the Fittydent™ tablet should only be proposed for those who use Deflex™, when two tablets are dropped into 150 mL water. PMID:29364341

  1. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    PubMed Central

    da SILVA, Paulo Maurício Batista; ACOSTA, Emílio José Tabaré Rodríguez; JACOBINA, Matheus; PINTO, Luciana de Rezende; PORTO, Vinícius Carvalho

    2011-01-01

    Objective Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Material and Methods Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. Results There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Conclusions Repeated immersion cycles in disinfecting solutions alter ∆E* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye. PMID:22230997

  2. Localizing softness and stress along loops in 3D topological metamaterials

    NASA Astrophysics Data System (ADS)

    Baardink, Guido; Souslov, Anton; Paulose, Jayson; Vitelli, Vincenzo

    2018-01-01

    Topological states can be used to control the mechanical properties of a material along an edge or around a localized defect. The rigidity of elastic networks is characterized by a topological invariant called the polarization; materials with a well-defined uniform polarization display a dramatic range of edge softness depending on the orientation of the polarization relative to the terminating surface. However, in all 3D mechanical metamaterials proposed to date, the topological modes are mixed with bulk soft modes, which organize themselves in Weyl loops. Here, we report the design of a 3D topological metamaterial without Weyl lines and with a uniform polarization that leads to an asymmetry between the number of soft modes on opposing surfaces. We then use this construction to localize topological soft modes in interior regions of the material by including defect lines—dislocation loops—that are unique to three dimensions. We derive a general formula that relates the difference in the number of soft modes and states of self-stress localized along the dislocation loop to the handedness of the vector triad formed by the lattice polarization, Burgers vector, and dislocation-line direction. Our findings suggest a strategy for preprogramming failure and softness localized along lines in 3D, while avoiding extended soft Weyl modes.

  3. Detection of Heating Processes in Coronal Loops by Soft X-ray Spectroscopy

    NASA Astrophysics Data System (ADS)

    Kawate, Tomoko; Narukage, Noriyuki; Ishikawa, Shin-nosuke; Imada, Shinsuke

    2017-08-01

    Imaging and Spectroscopic observations in the soft X-ray band will open a new window of the heating/acceleration/transport processes in the solar corona. The soft X-ray spectrum between 0.5 and 10 keV consists of the electron thermal free-free continuum and hot coronal lines such as O VIII, Fe XVII, Mg XI, Si XVII. Intensity of free-free continuum emission is not affected by the population of ions, whereas line intensities especially from highly ionized species have a sensitivity of the timescale of ionization/recombination processes. Thus, spectroscopic observations of both continuum and line intensities have a capability of diagnostics of heating/cooling timescales. We perform a 1D hydrodynamic simulation coupled with the time-dependent ionization, and calculate continuum and line intensities under different heat input conditions in a coronal loop. We also examine the differential emission measure of the coronal loop from the time-integrated soft x-ray spectra. As a result, line intensity shows a departure from the ionization equilibrium and shows different responses depending on the frequency of the heat input. Solar soft X-ray spectroscopic imager will be mounted in the sounding rocket experiment of the Focusing Optics X-ray Solar Imager (FOXSI). This observation will deepen our understanding of heating processes to solve the “coronal heating problem”.

  4. Virtual surgical planning for treatment of severe mandibular retrognathia with collapsed occlusion using contemporary surgical and prosthodontic protocols.

    PubMed

    Dhima, Matilda; Salinas, Thomas J; Rieck, Kevin L

    2013-11-01

    To meet functional and esthetic needs in an older adult for treatment of complex skeletal and dentoalveolar deformities using contemporary surgical and prosthodontic protocols. An older adult with dentoalveolar complex and skeletal deformity (mandibular retrognathia) was treated by a combination of virtual planning and current surgical and prosthodontic protocols. Treatment planning steps and sequencing are presented. Skeletal, soft tissue, and dental harmonies were attained without biological or mechanical complications. Definitive oral rehabilitation was completed with a maxillary complete denture and a mandibular metal ceramic fixed implant-retained prosthesis. A surgical and prosthodontic team approach in combination with technologic advances can predictably optimize esthetic and functional outcomes for patients with complex skeletal and dentoalveolar deformities. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Overdenture retained by teeth using a definitive denture base technique: a case report.

    PubMed

    Nascimento, D F F; dos Santos, J F F; Marchini, L

    2010-09-01

    This paper presents a technique involving the use of a definitive denture base to make overdentures. Cores with ball attachments were cemented over remaining lower teeth. Impressions of the edentulous maxilla and mandible were taken to obtain a definitive acrylic resin base. The definitive base of the mandible was perforated at the location of ball attachments and its female components were fixed to the base using acrylic resin directly in the patient's mouth. Wax rims were then made, jaw relationships recorded, teeth mounted and tried in, and the dentures were cured. This technique allowed for easy fixing of female components and better retention during the recording of jaw relationships, and can also be used in the construction of implant retained dentures.

  6. Simulation and observation of line-slip structures in columnar structures of soft spheres

    NASA Astrophysics Data System (ADS)

    Winkelmann, J.; Haffner, B.; Weaire, D.; Mughal, A.; Hutzler, S.

    2017-07-01

    We present the computed phase diagram of columnar structures of soft spheres under pressure, of which the main feature is the appearance and disappearance of line slips, the shearing of adjacent spirals, as pressure is increased. A comparable experimental observation is made on a column of bubbles under forced drainage, clearly exhibiting the expected line slip.

  7. Simulation and observation of line-slip structures in columnar structures of soft spheres.

    PubMed

    Winkelmann, J; Haffner, B; Weaire, D; Mughal, A; Hutzler, S

    2017-07-01

    We present the computed phase diagram of columnar structures of soft spheres under pressure, of which the main feature is the appearance and disappearance of line slips, the shearing of adjacent spirals, as pressure is increased. A comparable experimental observation is made on a column of bubbles under forced drainage, clearly exhibiting the expected line slip.

  8. Oral health-related quality of life in complete denture wearers depending on their socio-demographic background, prosthetic-related factors and clinical condition

    PubMed Central

    Perea, Carmen; Suárez-García, María J.; Del Río, Jaime; Torres-Lagares, Daniel; Montero, Javier

    2013-01-01

    Objectives: To investigate the differences in impact on oral health-related quality of life (OHRQoL) among complete denture wearers depending on their socio-demographic characteristics, prosthetic-related factors and oral status. Study Design: 51 patients aged 50-90 years treated, from 2005 to 2010, with at least one complete denture at the Department of Buccofacial Prostheses of the Complutense University (Madrid) were enrolled in this cross-sectional study. All of the participants answered the Oral Health Impact Profile (OHIP-14sp) questionnaire. The additive scoring method was used. The prevalence of impacts was calculated by using the occasional threshold (OHIP-14sp score≥2). Socio-demographic and prosthetic-related variables were gathered. Patients underwent clinical examination to assess their oral condition. Descriptive probes and Chi-Square tests were run (p≤0.05). Results: The predominant participants’ profile was that of a man with a mean age of 69 years wearing complete dentures in both the maxilla and the mandible. The prevalence of impact was 23.5%, showing an average score of 19±9.8. The most affected domains were “functional limitation” and “physical pain”, followed by “physical disability”. Minor impacts were recorded for the psychological and social subscales (“psychological discomfort”, “psychological disability”, “social disability” and “handicap”). The prosthesis’ location significantly influenced the overall patient satisfaction, the lower dentures being the less comfortable. Having a complete removable denture as antagonist significantly hampered the patient satisfaction. Patients without prosthetic stomatitis and those who need repairing or changing their prostheses, recorded significantly higher OHIP-14sp total scores. Conclusions: The use of conventional complete dentures brings negative impacts in the OHRQoL of elderly patients, mainly in case of lower prostheses that required reparation or substitution, with a removable total denture as antagonist. The prosthetic stomatitis in this study was always associated to other severe illness, which may have influenced the self-perceived discomfort with the prostheses, as those patients were daily medicated with painkillers. Key words:Oral Health Impact Profile (OHIP), oral health-related quality of life (OHRQoL), patient satisfaction, complete denture, elderly patients. PMID:23385509

  9. Shape Optimization for Additive Manufacturing of Removable Partial Dentures - A New Paradigm for Prosthetic CAD/CAM

    PubMed Central

    2015-01-01

    With ever-growing aging population and demand for denture treatments, pressure-induced mucosa lesion and residual ridge resorption remain main sources of clinical complications. Conventional denture design and fabrication are challenged for its labor and experience intensity, urgently necessitating an automatic procedure. This study aims to develop a fully automatic procedure enabling shape optimization and additive manufacturing of removable partial dentures (RPD), to maximize the uniformity of contact pressure distribution on the mucosa, thereby reducing associated clinical complications. A 3D heterogeneous finite element (FE) model was constructed from CT scan, and the critical tissue of mucosa was modeled as a hyperelastic material from in vivo clinical data. A contact shape optimization algorithm was developed based on the bi-directional evolutionary structural optimization (BESO) technique. Both initial and optimized dentures were prototyped by 3D printing technology and evaluated with in vitro tests. Through the optimization, the peak contact pressure was reduced by 70%, and the uniformity was improved by 63%. In vitro tests verified the effectiveness of this procedure, and the hydrostatic pressure induced in the mucosa is well below clinical pressure-pain thresholds (PPT), potentially lessening risk of residual ridge resorption. This proposed computational optimization and additive fabrication procedure provides a novel method for fast denture design and adjustment at low cost, with quantitative guidelines and computer aided design and manufacturing (CAD/CAM) for a specific patient. The integration of digitalized modeling, computational optimization, and free-form fabrication enables more efficient clinical adaptation. The customized optimal denture design is expected to minimize pain/discomfort and potentially reduce long-term residual ridge resorption. PMID:26161878

  10. Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitation

    PubMed Central

    Greven, Marcus; Wismeijer, Daniel

    2017-01-01

    PURPOSE To integrate extra-oral facial scanning information with CAD/CAM complete dentures to immediately rehabilitate terminal dentition. MATERIALS AND METHODS Ten patients with terminal dentition scheduled for total extraction and immediate denture placement were recruited for this study. The patients were submitted to a facial scanning procedure using the in-office PritiMirror scanner with bite registration records in-situ. Definitive stone cast models and bite records were subsequently submitted to a lab scanning procedure using the lab scanner (iSeries DWOS; Dental Wings). The scanned models were used to create a virtual teeth setup of a complete denture. Using the intra-oral bite records as a reference, the virtual setup was incorporated in the facial scan thereby facilitating a virtual clinical evaluation (teeth try-in) phase. After applying necessary adjustments, the virtual setup was submitted to a CAM procedure where a 5-axis industrial milling machine (M7 CNC; Darton AG General) was used to fabricate a full-milled PMMA immediate provisional prosthesis. RESULTS Total extractions were performed, the dentures were immediately inserted, and subjective clinical fit was evaluated. The immediate provisional prostheses were inserted and clinical fit, occlusion/articulation, and esthetics were subjectively assessed; the results were deemed satisfactory. All provisional prostheses remained three months in function with no notable technical complications. CONCLUSION Ten patients with terminal dentition were treated using a complete digital approach to fabricate complete dentures using CAD/CAM technology. The proposed technique has the potential to accelerate the rehabilitation procedure starting from immediate denture to final implant-supported prosthesis leading to more predictable functional and aesthetics outcomes. PMID:29142646

  11. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication.

    PubMed

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.

  12. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    PubMed Central

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  13. Patient ratings of chewing ability from a randomised crossover trial: lingualised vs. first premolar/canine-guided occlusion for complete dentures.

    PubMed

    Heydecke, Guido; Akkad, Ahmed Shadi; Wolkewitz, Martin; Vogeler, Michael; Türp, Jens C; Strub, Joerg R

    2007-06-01

    Complex procedures involving a facebow transfer and the use of lingualised teeth are deemed to have a positive influence on the chewing ability with complete dentures. To determine if patients' ratings of their ability to chew depend on the method of complete denture fabrication. Edentulous patients (n = 20) participated in a within-subject crossover trial. Each patient received two sets of new complete dentures. One pair was manufactured based on intraoral tracing of centric relation and facebow transfer; semi-anatomical teeth with lingualised occlusion denture (LOD) were chosen. The second pair was made using a simplified procedure without facebow transfer; jaw relations were recorded with wax occlusion rims, and anatomical teeth with a first premolar/canine-guidance (CGD) were selected. The dentures were delivered in randomised order, and each was worn for 3 months. Three months after delivery, patients' ratings of each new prosthesis were recorded on visual analogue scales for their ability to chew seven index foods. Repeated measurements analysis of variance was performed to investigate possible carry-over effects accounting for confounding by treatment period. When comparing the two treatments, participants rated their ability to chew in general, to masticate carrots, hard sausage, steak and raw apple in particular, was significantly better with the CGD (anatomical teeth) than with the LOD (p < 0.05). Comprehensive methods for the fabrication of complete dentures including semi-anatomical lingualised teeth and a full registration do not seem to influence the perceived chewing ability, when compared with more simple procedures. Chewing ability for tough foods appears to benefit from the use of anatomical teeth.

  14. Clinical acceptability of metal-ceramic fixed partial dental prosthesis fabricated with direct metal laser sintering technique-5 year follow-up

    PubMed Central

    Prabhu, Radhakrishnan; Prabhu, Geetha; Baskaran, Eswaran; Arumugam, Eswaran M.

    2016-01-01

    Statement of Problem: In recent years, direct metal laser sintered (DMLS) metal-ceramic-based fixed partial denture prostheses have been used as an alternative to conventional metal-ceramic fixed partial denture prostheses. However, clinical studies for evaluating their long-term clinical survivability and acceptability are limited. Aims and Objective: The aim of this study was to assess the efficacy of metal-ceramic fixed dental prosthesis fabricated with DMLS technique, and its clinical acceptance on long-term clinical use. Materials and Methods: The study group consisted of 45 patients who were restored with posterior three-unit fixed partial denture prosthesis made using direct laser sintered metal-ceramic restorations. Patient recall and clinical examination of the restorations were done after 6months and every 12 months thereafter for the period of 60 months. Clinical examination for evaluation of longevity of restorations was done using modified Ryge criteria which included chipping of the veneered ceramic, connector failure occurring in the fixed partial denture prosthesis, discoloration at the marginal areas of the veneered ceramic, and marginal adaptation of the metal and ceramic of the fixed denture prosthesis. Periapical status was assessed using periodical radiographs during the study period. Survival analysis was made using the Kaplan–Meier method. Results: None of the patients had failure of the connector of the fixed partial denture prostheses during the study period. Two exhibited biological changes which included periapical changes and proximal caries adjacent to the abutments. Conclusion: DMLS metal-ceramic fixed partial denture prosthesis had a survival rate of 95.5% and yielded promising results during the 5-year clinical study. PMID:27141171

  15. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base

    PubMed Central

    Shinawi, Lana Ahmed

    2017-01-01

    Background The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. Aim To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. Methods This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. Results ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. Conclusion CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits. PMID:28713496

  16. Chronological grey scale changes in supporting alveolar bone by removable partial denture placement on patients with periodontal disease: A 6-month follow-up study using digital subtraction analysis.

    PubMed

    Watanabe, Chie; Wada, Junichiro; Mizutani, Koji; Watanabe, Hiroshi; Wakabayashi, Noriyuki

    2017-08-01

    The purpose was to assess the early effects of removable partial denture (RPD) placement on abutment teeth in patients with periodontal disease. Fifteen distal-extension RPDs and 19 abutment teeth were evaluated in 13 patients with moderate-to-severe periodontal diseases. Clinical periodontal records and grey level (GL) score based on digital subtraction radiography were measured on the day of denture placement (baseline) and at 1day, 1 week, 1 month, 3 months, and 6 months after the placement. Occlusal force on total dentition (Ft) and abutment tooth (Fa) were recorded with (baseline) and without denture on the day of the placement, and with denture in the follow-up examinations. No statistically significant difference between a follow-up period and the baseline was found in the clinical periodontal and occlusal force records, except for Ft with denture on the day of the placement, which was significantly lower than the baseline (p<0.05). The GL at distal crestal of the abutment was significantly higher at 1 week after the placement than at the baseline (p<0.05), while the scores of following examinations returned to the baseline level. The distal crestal bone of the abutment tooth transitorily reacts to mechanical stress due to the denture placement, while this does not suggest a detrimental effect within the limitation of the study design with a short-term observation period. The RPDs can be safely used for patients with periodontal diseases for at least 6 months if they are properly placed and maintained by professional care. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. CHIPPING FRACTURE RESISTANCE OF DENTURE TOOTH MATERIALS

    PubMed Central

    Quinn, G. D.; Giuseppetti, A. A.; Hoffman, K. H.

    2014-01-01

    Objective The applicability of the edge chipping method to denture tooth materials was assessed. These are softer materials than those usually tested by edge chipping. The edge chipping fracture resistances of polymethylmethacrylate (PMMA) based and two filled resin composite denture tooth materials were compared. Methods An edge chipping machine was used to chip rectangular blocks and flattened anterior denture teeth. Force versus edge distance data were collected over a broad range of forces and distances. Between 20 and 65 chips were made per condition depending upon the material, the scatter, and the indenter type. Different indenter types were used including Rockwell C, sharp conical 120°, Knoop, and Vickers. The edge toughness, Te, was evaluated for different indenter types. Results The edge chipping data collected on the blocks matched the data collected from flattened teeth. High scatter, particularly at large distances and loads, meant that many tests (up to 64) were necessary to compare the denture tooth materials and to ascertain the appropriate data trends. A linear force – distance trend analysis was adequate for comparing these materials. A power law trend might be more appropriate, but the large scatter obscured the definitive determination of the precise trend. Different indenters produce different linear trends, with the ranking of: sharp conical 120°, Rockwell C, and Knoop, from lowest to highest edge toughness. Vickers indenter data were extremely scattered and a sensible trend could not be obtained. Edge toughness was inversely correlated to hardness. Significance Edge chipping data collected either from simple laboratory scale test blocks or from actual denture teeth may be used to evaluate denture materials. The edge chipping method’s applicability has been extended to another class of restorative materials. PMID:24674342

  18. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    PubMed

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  19. Oral manifestations of diabetes mellitus in complete denture wearers.

    PubMed

    Cristina de Lima, Danielle; Nakata, Gislaine Cristina; Balducci, Ivan; Almeida, Janete Dias

    2008-01-01

    The oral mucosa has been reported to show a variety of changes in subjects with diabetes mellitus. The purpose of this study was to compare diabetic and nondiabetic subjects wearing complete dentures with regard to salivary flow, salivary buffering capacity, denture retention, and oral mucosal lesions. Sixty subjects, 30 with and 30 without a diagnosis of diabetes, were matched for gender, race, and age. Salivary flow, salivary buffering capacity, glycemia, blood pressure, presence of mucosal lesions, denture retention, use of medications, and behavioral factors (controlled or uncontrolled diet, alcohol consumption, and smoking) reported by the subjects, were evaluated. For the salivary buffering capacity test, 1 mL of saliva was pipetted into a test tube containing 3 mL 0.005 N of hydrochloric acid, and the pH was measured with indicator strips. Group differences were statistically analyzed using the Student t test and the Mann-Whitney test for quantitative variables and the chi-square test for qualitative variables (alpha =.05). Mean (SD) salivary flow was 1.14 (0.87) mL/min in the nondiabetic subjects and 0.95 (0.61) mL/min in the diabetic subjects. Evaluation of self-reported denture retention revealed no significant difference between groups. Denture retention was observed in 66.7% (20/30) of the control group and in 50% (15/30) of the diabetic group. The prevalence of mucosal lesions was 90% (27/30) in the control group and 83.3% (25/30) in the diabetic group. Salivary buffering capacity was 5.80 (0.85) in the control group and 5.26 (0.83) in the diabetic group (P=.017). Within the limitations of this study, no significant differences were observed in salivary flow, denture retention, or oral lesions in diabetic and nondiabetic subjects.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szulagyi, Judit; Pascucci, Ilaria; Abraham, Peter

    Mid-infrared atomic and ionic line ratios measured in spectra of pre-main-sequence stars are sensitive indicators of the hardness of the radiation field impinging on the disk surface. We present a low-resolution Spitzer IRS search for [Ar II] at 6.98 {mu}m, [Ne II] at 12.81 {mu}m, and [Ne III] 15.55 {mu}m lines in 56 transitional disks. These objects, characterized by reduced near-infrared but strong far-infrared excess emission, are ideal targets to set constraints on the stellar radiation field onto the disk, because their spectra are not contaminated by shock emission from jets/outflows or by molecular emission lines. After demonstrating that wemore » can detect [Ne II] lines and recover their fluxes from the low-resolution spectra, here we report the first detections of [Ar II] lines toward protoplanetary disks. We did not detect [Ne III] emission in any of our sources. Our [Ne II]/[Ne III] line flux ratios combined with literature data suggest that a soft-EUV or X-ray spectrum produces these gas lines. Furthermore, the [Ar II]/[Ne II] line flux ratios point to a soft X-ray and/or soft-EUV stellar spectrum as the ionization source of the [Ar II] and [Ne II] emitting layer of the disk. If the soft X-ray component dominates over the EUV, then we would expect larger photoevaporation rates and, hence, a reduction of the time available to form planets.« less

  1. Light weight dentures: An innovative technique.

    PubMed

    Gundawar, Sham; Zamad, Aakanksha; Gundawar, Sneha

    2014-01-01

    Retention, stability and support are the basic principles on which the success of a complete denture relies. The severely resorbed maxillary and mandibular edentulous arches that are narrow and constricted with increased interarch space provide decreased support, retention and stability. To decrease the leverage, reduction in the weight of the prosthesis was recommended and also found beneficial. This article describes a simple procedure to reduce the weight of maxillary complete denture by use of an autopolymerizing acrylic resin shell which is incorporated during the packing stage. This method has the advantage of being easy and requires very little additional time. Hollow maxillary complete denture considerably reduces the weight of the prosthesis, which in turn prevents transmission of detrimental forces by reducing leverage action. This results in increased retention and stability and up to some extent it also preserves the existing residual alveolar ridge. The technique uses a clear matrix of trial denture to facilitate shaping of dough spacer to ensure an even thickness of acrylic to resist deformation and prevent seepage of saliva into the cavity making this technique more predictable. An autopolymerizing acrylic resin shell which creates hollow space and also has strength. Technique is simple to execute, easy economical and matching the shade of autopolymerizing acrylic resin with heat cures acrylic resin enhances esthetics. Light weight hollow dentures provide healthy and comfortable living for the geriatric edentulous patient.

  2. Comparison of using different bridge prosthetic designs for partial defect restoration through mathematical modeling.

    PubMed

    Styranivska, Oksana; Kliuchkovska, Nataliia; Mykyyevych, Nataliya

    2017-01-01

    To analyze the stress-strain states of bone and abutment teeth during the use of different prosthetic designs of fixed partial dentures with the use of relevant mathematical modeling principles. The use of Comsol Multiphysics 3.5 (Comsol AB, Sweden) software during the mathematical modeling of stress-strain states provided numerical data for analytical interpretation in three different clinical scenarios with fixed dentures and different abutment teeth and demountable prosthetic denture with the saddle-shaped intermediate part. Microsoft Excel Software (Microsoft Office 2017) helped to evaluate absolute mistakes of stress and strain parameters of each abutment tooth during three modeled scenarios and normal condition and to summarize data into the forms of tables. In comparison with the fixed prosthetic denture supported by the canine, first premolar, and third molar, stresses at the same abutment teeth with the use of demountable denture with the saddle-shaped intermediate part decreased: at the mesial abutment tooth by 2.8 times, at distal crown by 6.1 times, and at the intermediate part by 11.1 times, respectively, the deformation level decreased by 3.1, 1.9, and 1.4 times at each area. The methods of mathematical modeling proved that complications during the use of fixed partial dentures based on the overload effect of the abutment teeth and caused by the deformation process inside the intermediate section of prosthetic construction.

  3. Rechargeable anticandidal denture material with sustained release in saliva.

    PubMed

    Malakhov, A; Wen, J; Zhang, B-X; Wang, H; Geng, H; Chen, X-D; Sun, Y; Yeh, C-K

    2016-07-01

    Candida-induced denture stomatitis is a common debilitating problem among denture wearers. Previously, we described the fabrication of a new denture material that released antifungal drugs when immersed in phosphate buffered saline. Here, we use more clinically relevant immersion conditions (human saliva; 37°C) and measure miconazole release and bioactivity. Disks were prepared by grafting PNVP [poly(N-vinyl-2-pyrrolidinone)] onto PMMA [poly(methylmethacrylate)] using plasma initiation (PMMA-g-PNVP) and then loaded with miconazole. Drug-loaded disks were immersed in 10-100% human saliva (1-30 days). Miconazole release was measured and then tested for bioactivity vs miconazole-sensitive and miconazole-resistant Candida isolates. HPLC was used to quantify miconazole levels in saliva. Miconazole-loaded disks released antifungal drug for up to 30 days. Higher drug release was found with higher concentrations of saliva, and, interestingly, miconazole solubility was increased with higher saliva concentrations. The released miconazole retained its anticandidal activity. After immersion, the residual miconazole could be quenched and the disks recharged. Freshly recharged disks displayed the same release kinetics and bioactivity as the original disks. Quenched disks could also be charged with chlorhexidine that displayed anticandidal activity. These results suggest that PMMA-g-PNVP is a promising new denture material for long-term management of denture stomatitis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. In Vitro Evaluation of the Inhibitory Activity of Thymoquinone in Combatting Candida albicans in Denture Stomatitis Prevention

    PubMed Central

    Al-Khalifa, Khalifa S.; Gad, Mohammed M.; Al-Hariri, Mohammed; Alnassar, Talal

    2017-01-01

    Candida albicans adhesion and proliferation on denture bases may lead to denture stomatitis, which is a common and recurrent problem in denture wearers. The goal of this study was to assess the inhibitory effect of thymoquinone incorporated in the polymethyl methacrylate denture base material against Candida albicans. Eighty acrylic resin specimens were fabricated and divided into eight groups (n = 10) according to thymoquinone concentrations of 0.5%, 1%, 1.5%, 2%, 2.5%, 3%, and 5% of acrylic powder. Two methods were used to evaluate the effect of thymoquinone on Candida albicans: the slide count and the serial dilution test. A multivariate analysis of variance (MANOVA) and the post-hoc Tukey’s Honestly Significant Difference (HSD) test were performed to compare the difference of means between the observations taken at various intervals with baseline. The p value was statistically significant at ≤0.05. According to the slide count and the serial dilution test, the mean number of adhered Candida albicans in the control group was 5436.9 ± 266 and 4691.4 ± 176.8; however, this number dramatically decreased to 0 ± 0 and 32.4 ± 1.7 in group 8 (concentration 5%). These results suggest that the incorporation of thymoquinone into the acrylic resin denture base material might be effective in preventing Candida albicans adhesion. PMID:28698449

  5. Speech intelligibility enhancement after maxillary denture treatment and its impact on quality of life.

    PubMed

    Knipfer, Christian; Riemann, Max; Bocklet, Tobias; Noeth, Elmar; Schuster, Maria; Sokol, Biljana; Eitner, Stephan; Nkenke, Emeka; Stelzle, Florian

    2014-01-01

    Tooth loss and its prosthetic rehabilitation significantly affect speech intelligibility. However, little is known about the influence of speech deficiencies on oral health-related quality of life (OHRQoL). The aim of this study was to investigate whether speech intelligibility enhancement through prosthetic rehabilitation significantly influences OHRQoL in patients wearing complete maxillary dentures. Speech intelligibility by means of an automatic speech recognition system (ASR) was prospectively evaluated and compared with subjectively assessed Oral Health Impact Profile (OHIP) scores. Speech was recorded in 28 edentulous patients 1 week prior to the fabrication of new complete maxillary dentures and 6 months thereafter. Speech intelligibility was computed based on the word accuracy (WA) by means of an ASR and compared with a matched control group. One week before and 6 months after rehabilitation, patients assessed themselves for OHRQoL. Speech intelligibility improved significantly after 6 months. Subjects reported a significantly higher OHRQoL after maxillary rehabilitation with complete dentures. No significant correlation was found between the OHIP sum score or its subscales to the WA. Speech intelligibility enhancement achieved through the fabrication of new complete maxillary dentures might not be in the forefront of the patients' perception of their quality of life. For the improvement of OHRQoL in patients wearing complete maxillary dentures, food intake and mastication as well as freedom from pain play a more prominent role.

  6. Wetting and phase separation in soft adhesion

    PubMed Central

    Jensen, Katharine E.; Sarfati, Raphael; Style, Robert W.; Boltyanskiy, Rostislav; Chakrabarti, Aditi; Chaudhury, Manoj K.; Dufresne, Eric R.

    2015-01-01

    In the classic theory of solid adhesion, surface energy drives deformation to increase contact area whereas bulk elasticity opposes it. Recently, solid surface stress has been shown also to play an important role in opposing deformation of soft materials. This suggests that the contact line in soft adhesion should mimic that of a liquid droplet, with a contact angle determined by surface tensions. Consistent with this hypothesis, we observe a contact angle of a soft silicone substrate on rigid silica spheres that depends on the surface functionalization but not the sphere size. However, to satisfy this wetting condition without a divergent elastic stress, the gel phase separates from its solvent near the contact line. This creates a four-phase contact zone with two additional contact lines hidden below the surface of the substrate. Whereas the geometries of these contact lines are independent of the size of the sphere, the volume of the phase-separated region is not, but rather depends on the indentation volume. These results indicate that theories of adhesion of soft gels need to account for both the compressibility of the gel network and a nonzero surface stress between the gel and its solvent. PMID:26553989

  7. Study on Antibacterial Property of PMMA Denture Base Materials with Negative Ion Powder

    NASA Astrophysics Data System (ADS)

    Liu, Meitian; Zhang, Xiaohui; Zhang, Jingting; Zheng, Qian; Liu, Bin

    2018-01-01

    To prepare the denture base resin with negative ion powder and evaluate the antibacterial effect of denture base resin with different contents of negative ion powder for clinical application. Method: Denture base material with negative ion powder was prepared by in-situ polymerization method, 50mm * 50mm * 2mm standard samples were prepared respectively. Antibacterial properties were tested with the film contact method. Experimental bacteria: Staphylococcus aureus (ATCC6538), Escherichia coli (ATCC8099).Result:With the increase of the amount of negative ion powder, the inhibition rate of the composite material to Escherichia coli and Staphylococcus aureus showed an increasing trend, and the number of residual bacteria on the surface showed a decreasing trend. When the content of negative ion powder was 2%, the composite material Staphylococcus aureus and Escherichia coli were 77.9% and 80.3% respectively. When the addition ratio was 5%, the bactericidal rate of the composite material to Staphylococcus aureus and Escherichia coli reached 98.2% and 99.1% respectively. Conclusion: The denture base material containing more than 2%wt negative ion powder has strong sterilization.

  8. Study of denture-induced fibrous hyperplasia cases diagnosed from 1979 to 2001.

    PubMed

    Macedo Firoozmand, Leily; Dias Almeida, Janete; Guimarães Cabral, Luiz Antonio

    2005-01-01

    The purpose of this research was to study the cases of inflammatory fibrous hyperplasia (IFH) at the Clinic of Semiology, Department of Bioscience and Oral Diagnosis, São Jose dos Campos Dental School, State University of São Paulo, Brazil. A total of 141 clinical file cards indicating a final diagnosis of IFH, from the archives of the Department of Bioscience and Oral Diagnosis and dated from 1979 to 2001, were included in the study. Of these files, 50 indicated a diagnosis of denture-induced fibrous hyperplasia. Sex, age, race, duration, and clinical features that confirm their classification in the non-neoplastic proliferating process were analyzed statistically. Of the 50 analyzed cases of denture-induced lesion, 22% occurred in men and 78% in women. Patients in the age group of 41 to 50 years presented the highest frequency of the lesion. Inflammatory fibrous hyperplasia occurs more frequently in women (71.63%), and denture-induced lesions appear mainly in patients over 40 years of age (70% of cases). Patients with denture-induced hyperplasia reported pain associated with the lesion (70%).

  9. Effect of thermal shock on mechanical properties of injection-molded thermoplastic denture base resins.

    PubMed

    Takahashi, Yutaka; Hamanaka, Ippei; Shimizu, Hiroshi

    2012-07-01

    This study investigated the effect of thermal shock on the mechanical properties of injection-molded thermoplastic denture base resins. Four thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were tested. Specimens of each denture base material were fabricated according to ISO 1567 and were either thermocycled or not thermocycled (n = 10). The flexural strength at the proportional limit (FS-PL), the elastic modulus and the Charpy impact strength of the denture base materials were estimated. Thermocycling significantly decreased the FS-PL of one of the polyamides and the PMMA and it significantly increased the FS-PL of one of the polyamides. In addition, thermocycling significantly decreased the elastic modulus of one of the polyamides and significantly increased the elastic moduli of one of the polyamides, the polyethylene terephthalate, polycarbonate and PMMA. Thermocycling significantly decreased the impact strength of one of the polyamides and the polycarbonate. The mechanical properties of injection-molded thermoplastic denture base resins changed after themocycling.

  10. Copper vapour laser ID labelling on metal dentures and restorations.

    PubMed

    Ling, B C; Nambiar, P; Low, K S; Lee, C K

    2003-06-01

    Denture marking is accepted as a means of identifying dentures and persons in geriatric institutions, or post-mortem during war, crimes, civil unrest, natural and mass disasters. Labelling on the acrylic resin component of the denture can easily be damaged or destroyed by fire but on cobalt-chromium components it would be more resistant. A copper vapour laser (CVL) can be used to label the cobalt-chromium components of dentures and metal restorations easily, and legibly, and miniaturised for the incorporation of more personal particulars necessary for the identification of the deceased person. The CVL beam is focussed by its optics and delivered to the material surface by the two-axis scanner mounted with mirrors. A personal computer controls the movement of the scanner and the firing of the CVL. The high peak power of the pulsed CVL is focussed to very high energy density producing plasma ablation of the alloy surface. Very fine markings of a few microns width can be produced enabling the storage of detailed information of the deceased person on a metal surface for the purpose of rapid identification.

  11. Application of sintered titanium alloys to metal denture bases: a study of titanium powder sheets for complete denture base.

    PubMed

    Doi, H; Harrori, M; Hasegawa, K; Yoshinari, M; Kawada, E; Oda, Y

    2001-02-01

    The purpose of this study was the fabrication of titanium powder sheets to enable the application of sintered titanium alloys as metal denture bases. The effects of titanium particle shape and size, binder content, and plasticizer content on the surface smoothness, tensile strength and elongation of titanium powder sheets was investigated. To select a suitable ratio of powdered metal contents for application as a metal denture base, the effects of aluminum content in Ti sheets and various other powder metal contents in Ti-Al sheets on the density, sintering shrinkage, and bending strength were evaluated. Based on the results of the above experiments, we developed a mixed powder sheet composed of 83Ti-7Al-10Cr with TA45 titanium powder (atomized, -45 microm), and 8 mass% binder content. This titanium alloy sheet had good formability and ductility. Its sintered titanium alloy had a density of 3.2 g/cm3, sintering shrinkage of 3.8%, and bending strength of 403 MPa. The titanium alloy sheet is clinically acceptable for fabricating denture bases.

  12. Finite element analysis of provisional structures of implant-supported complete prostheses.

    PubMed

    Carneiro, Bruno Albuquerque; de Brito, Rui Barbosa; França, Fabiana Mantovani Gomes

    2014-04-01

    The use of provisional resin implant-supported complete dentures is a fast and safe procedure to restore mastication and esthetics of patients soon after surgery and during the adaptation phase to the new denture. This study assessed stress distribution of provisional implant-supported fixed dentures and the all-on-4 concept using self-curing acrylic resin (Tempron) and bis-acrylic resin (Luxatemp) to simulate functional loads through the three-dimensional finite element method. Solidworks software was used to build three-dimensional models using acrylic resin (Tempron, model A) and bis-acrylic resin (Luxatemp, model B) for denture captions. Two loading patterns were applied on each model: (1) right unilateral axial loading of 150 N on the occlusal surfaces of posterior teeth and (2) oblique loading vector of 150 N at 45°. The results showed that higher stress was found on the bone crest below oblique load application with a maximum value of 187.57 MPa on model A and 167.45 MPa on model B. It was concluded that model B improved stress distribution on the denture compared with model A.

  13. Incorporation of Radio Frequency Identification Tag in Dentures to Facilitate Recognition and Forensic Human Identification

    PubMed Central

    Nuzzolese, E; Marcario, V; Di Vella, G

    2010-01-01

    Forensic identification using odontology is based on the comparison of ante-mortem and post mortem dental records. The insertion of a radio frequency identification (RFId) tag into dentures could be used as an aid to identify decomposed bodies, by storing personal identification data in a small transponder that can be radio-transmitted to a reader connected to a computer. A small passive, 12 x 2,1 mm, read-only RFId-tag was incorporated into the manufacture of three trial complete upper dentures and tested for a signal. The aim of this article is to demonstrate the feasibility of manufacturing such a dental prosthesis, the technical protocols for its implantation in the denture resin and its working principles. Future research and tests are required in order to verify human compatibility of the tagged denture and also to evaluate any potential deterioration in strength when subjected to high temperatures, or for damage resulting from everyday wear and tear. It should also be able to withstand the extreme conditions resulting from major accidents or mass disasters and procedures used to perform a forensic identification. PMID:20657641

  14. Influence of inner circular sealing area impression method on the retention of complete dentures.

    PubMed

    Wang, Cun-Wei; Shao, Qi; Sun, Hui-Qiang; Mao, Meng-Yun; Zhang, Xin-Wei; Gong, Qi; Xiao, Guo-Ning

    2015-01-01

    The aims of the present study were to describe an impression method of "inner circular sealing area" and to evaluate the effect of the method on retention, aesthetics and comfort of complete dentures, which lack labial base for patients with maxillary protrusions. Three patients were subjected to the experiment, and two sets of complete maxillary dentures were made for each patient; the first set was made without labial base via an inner circular sealing area method (experimental group) and the second had an intact base that was made with conventional methods (control group). Retention force tests were implemented with a tensile strength assessment device to assess the retention and a visual analogue scale (VAS) was used to evaluate the comfort between the two groups. Results showed larger retention force, better aesthetics and more comfort in the experimental group. The improved two-step impression method formed an inner circular sealing area that prevented damage to the peripheral border seal effect of the denture caused by incomplete bases and obtained better denture retention.

  15. SLAC Phone Directory: Search Form

    Science.gov Websites

    Facilities LCLS Hard X-Ray LCLS IT & Networking LCLS IT Photon Systems LCLS Instrumentation Dev LCLS Delivery Dept LCLS Science Research & DevDiv LCLS Soft X-Ray LCLS Technical Support LCLS User Beam Line Ops Sup SSRL MSD Hard X-rays SSRL MSD Soft X-rays SSRL MSDBeam Line Elec SSRL MSDBeam Line

  16. Hader bar and clip attachment retained mandibular complete denture

    PubMed Central

    Singh, Kunwarjeet; Gupta, Nidhi; Kapoor, Vikram; Gupta, Ridhimaa

    2013-01-01

    Bar and clip attachments significantly improve the level of satisfaction of denture-wearing patients by enhancing the retention and stability of the prosthesis. These attachments have been most commonly used for connecting the prosthesis to implants, but they can be effectively used to retain tooth-supported prosthesis as well. The primary functions of bar attachments are splinting the abutments together, even distribution of forces to the abutments and supporting areas, guiding the prosthesis into place, improving the retention, stability, support and comfort of the patient. The primary requirement for the use of bar attachments is the availability of sufficient vertical and buccolingual space for the proper placement of the bar, sleeves, teeth arrangement and sufficient thickness of acrylic denture base to minimise incidence of denture fracture in the area of bar assembly. PMID:24145505

  17. Hader bar and clip attachment retained mandibular complete denture.

    PubMed

    Singh, Kunwarjeet; Gupta, Nidhi; Kapoor, Vikram; Gupta, Ridhimaa

    2013-10-21

    Bar and clip attachments significantly improve the level of satisfaction of denture-wearing patients by enhancing the retention and stability of the prosthesis. These attachments have been most commonly used for connecting the prosthesis to implants, but they can be effectively used to retain tooth-supported prosthesis as well. The primary functions of bar attachments are splinting the abutments together, even distribution of forces to the abutments and supporting areas, guiding the prosthesis into place, improving the retention, stability, support and comfort of the patient. The primary requirement for the use of bar attachments is the availability of sufficient vertical and buccolingual space for the proper placement of the bar, sleeves, teeth arrangement and sufficient thickness of acrylic denture base to minimise incidence of denture fracture in the area of bar assembly.

  18. Connecting and disconnecting nematic disclination lines in microfluidic channels.

    PubMed

    Agha, Hakam; Bahr, Christian

    2016-05-14

    Disclination lines in nematic liquid crystals can be used as "soft rails" for the transport of colloids or droplets through microfluidic channels [A. Sengupta, C. Bahr and S. Herminghaus, Soft Matter, 2013, 9, 7251]. In the present study we report on a method to connect and disconnect disclination lines in microfluidic channels using the interplay between anchoring, flow, and electric field. We show that the application of an electric field establishes a continuous disclination that spans across a channel region in which a disclination usually would not exist (because of different anchoring conditions), demonstrating an interruptible and reconnectable soft rail for colloidal transport.

  19. Tooth wear and loss: symptomatological and rehabilitating treatments.

    PubMed

    Hotta, T H; Nunes, L J; Quatrini, A H; Bataglion, C; Nonaka, T; Bezzon, O L

    2000-01-01

    The authors report a clinical case that presented tooth wear and absence, with painful muscular and articular symptomatology, and also alteration in deglutition, mastication and speech. The clinical procedures used were re-establishment of vertical dimension of occlusion, mandibular centric relations, and occlusal contacts through therapeutic removable partial dentures. The condyle position was analyzed in habitual occlusion and in occlusion with dentures, through transcranial radiographs of the temporomandibular joints. Oral rehabilitation was achieved with dental restoration and removable partial dentures.

  20. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    PubMed

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  1. CAD/CAM complete dentures: a review of two commercial fabrication systems.

    PubMed

    Kattadiyil, Mathew T; Goodacre, Charles J; Baba, Nadim Z

    2013-06-01

    The use of computer-aided design and computer-aided manufacturing (CAD/CAM) has become available for complete dentures through the AvaDent and Dentca systems. AvaDent uses laser scanning and computer technology. Teeth are arranged and bases formed using proprietary software.The bases are milled from prepolymerized pucks of resin. Dentca uses computer software to produce virtual maxillary and mandibular edentulous ridges, arrange the teeth and form bases. The dentures are fabricated using a conventional processing technique.

  2. An overview of removable partial overdentures.

    PubMed

    McDermott, I G; Samant, A

    1990-02-01

    As an alternative to complete dentures, overdentures are well established as a sound therapeutic modality for patients with terminal dentition. By utilizing natural tooth roots and their periodontal structures to aid in support, overdentures maintain proprioceptive mediation and a mechanism for masticatory force vectors that favor bone retention over bond resorption. The degree of stability enhancement and denture retention from retained roots varies with the design and environment of the prosthesis. This article reviews various aspects of removable partial over-denture use.

  3. Biofilm development by blastospores and hyphae of Candida albicans on abraded denture acrylic resin surfaces.

    PubMed

    Jackson, Sarah; Coulthwaite, Lisa; Loewy, Zvi; Scallan, Anthony; Verran, Joanna

    2014-10-01

    Candida albicans is a known etiologic agent of denture stomatitis. Candida hyphae exhibit the ability to respond directionally to environmental stimuli. This characteristic is thought to be important in the penetration of substrata such as resilient denture liners and host epithelium. It has been suggested that hyphal production also enhances adhesion and survival of Candida on host and denture surfaces. Surface roughness, in addition, can enhance adhesion where stronger interactions occur between cells and surface features of similar dimensions. The purpose of this study was to assess the development of hyphal and blastospore biofilms on abraded denture acrylic resin specimens and measure the ease of removal of these biofilms. Biofilms were grown for 48 hours on abraded 1-cm² denture acrylic resin specimens from adhered hyphal phase C albicans or from adhered blastospores. Subsequently, all specimens were stained with Calcofluor White and examined with confocal scanning laser microscopy. Biofilms were removed by vortex mixing in sterile phosphate buffered saline solution. Removed cells were filtered (0.2-μm pore size). Filters were dried at 37°C for 24 hours for dry weight measurements. Any cells that remained on the acrylic resin specimens were stained with 0.03% acridine orange and examined with epifluorescence microscopy. Biofilms grown from both cell types contained all morphologic forms of C albicans. Although the underlying surface topography did not affect the amount of biofilm produced, biofilms grown from hyphal phase Candida were visibly thicker and had greater biomass (P<.05). These biofilms were less easily removed from the denture acrylic resin, especially in the case of rougher surfaces, evidenced by the higher numbers of retained cells (P≤.05). The presence of hyphae in early Candida biofilms increased biofilm mass and resistance to removal. Increased surface roughness enhances retention of hyphae and yeast cells, and, therefore, will facilitate plaque regrowth. Therefore, minimization of denture abrasion during cleaning is desirable. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Does a mandibular overdenture improve nutrient intake and markers of nutritional status better than conventional complete denture? A systematic review and meta-analysis.

    PubMed

    Yamazaki, Toru; Martiniuk, Alexandra Lc; Irie, Koichiro; Sokejima, Shigeru; Lee, Crystal Man Ying

    2016-08-03

    The need for denture treatment in public health will increase as the population ages. However, the impact of dentures on nutrition, particularly overdenture treatment, remains unclear although the physical and psychological effects are known. We investigated whether treatment with a mandibular implant supported overdenture improves nutrient intake and markers of nutritional status better than a conventional complete denture in edentulous patients. Systematic review and meta-analysis. Medline, EMBASE and the Cochrane Central Register of Controlled Trials were searched for eligible studies published up to April 2016. We included studies which compared the treatment effect of an overdenture to conventional denture on nutrition, in which primary outcomes included changes in intake of macronutrients and/or micronutrients and/or indicators of nutritional status. Two reviewers independently evaluated eligible studies and assessed the risk of bias. We used a fixed effects model to estimate the weighted mean difference (WMD) and 95% CI for change in body mass index (BMI), albumin and serum vitamin B12 between overdenture and conventional denture 6 months after treatment. Of 108 eligible studies, 8 studies involving 901 participants were included in the narrative appraisal. Four studies reported changes in markers of nutritional status and nutrient intake after treatment with a prosthetic, regardless of type. In a meta-analysis of 322 participants aged 65 years or older from three studies, pooled analysis suggested no significant difference in change in BMI between an overdenture and conventional denture 6 months after treatment (WMD=-0.18 kg/m(2) (95% CI -0.52 to 0.16)), and no significant difference in change in albumin or vitamin B12 between the two treatments. The modifying effect of overdenture treatment on nutritional status might be limited. Further studies are needed to evaluate the effectiveness and efficacy of denture treatments. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Impact of implant-supported prostheses on nutritional status and oral health perception in edentulous patients.

    PubMed

    El Osta, Nada; El Osta, Lana; Moukaddem, Farah; Papazian, Tatiana; Saad, Robert; Hennequin, Martine; Rabbaa Khabbaz, Lydia

    2017-04-01

    Improvement of nutritional status and perception of oral health are supposed to be different with complete conventional denture or implant-supported fixed or removable prostheses. Since no study has been conducted in Lebanon, the aim of our study was to assess the nutritional status and oral heath related quality of life (OHRQoL) in totally edentulous patients after treatment with complete denture or implant supported-prostheses. This was an observational clinical prospective study. A convenient sample of Lebanese people aged 60 years or more was selected between September 2013 and July 2015 from the Departments of removable and fixed prosthesis at Saint-Joseph University of Beirut. The treatment options included complete denture, implant-supported complete denture and implant-supported fixed prostheses. Nutritional status and OHRQoL were assessed with the Mini-Nutritional Assessment Index (MNA) and the Geriatric Oral Health Assessment Index (GOHAI) respectively at Baseline (first visit before treatment), 2-3 weeks after treatment (t1), 3 months (t2) and 6 months (t3) after treatment. Fifty-one participants (mean age: 69.39 ± 7.164 years) were included. The results have shown an improvement over time in nutritional status and OHRQoL for all treatment groups. However, 2-3 weeks after treatment the number of participants at risk of malnutrition was higher with complete removable denture, intermediate with implant-supported complete denture and lower with implant-supported fixed prostheses (p-value = 0.049). Moreover, the mean GOHAI score was significantly lower over time with complete removable denture compared to implant-supported prostheses (p-value <0.05). Our study has shown an enhancement in the quality of life and the nutritional status for implant supported-prostheses compared to conventional removable dentures. Therefore, it is fundamental that dentists communicate with their patients about implant treatment to understand their expectations, to explain the outcomes and achieve the desired clinical result. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  6. Influence of matrix attachment installation load on movement and resultant forces in implant overdentures.

    PubMed

    Goto, Takaharu; Nagao, Kan; Ishida, Yuichi; Tomotake, Yoritoki; Ichikawa, Tetsuo

    2015-02-01

    This in vitro study investigated the effect of attachment installation conditions on the load transfer and denture movements of implant overdentures, and aims to clarify the differences among the three types of attachments, namely ball, Locator, and magnet attachments. Three types of attachments, namely ball, Locator, and magnetic attachments were used. An acrylic resin mandibular edentulous model with two implants placed in the bilateral canine regions and removable overdenture were prepared. The two implants and bilateral molar ridges were connected to three-axis load-cell transducers, and a universal testing machine was used to apply a 50 N vertical force to each site of the occlusal table in the first molar region. The denture movement was measured using a G(2) motion sensor. Three installation conditions, namely, the application of 0, 50, and 100 N loads were used to install each attachment on the denture base. The load transfer and denture movement were then evaluated. The resultant force decreased with increasing installation load for all attachments. In particular, the resultant force on implants on the loading side of the Locator attachment significantly decreased when the installation load was increased from 0 to 50 N, and that for magnetic attachment significantly decreased when the installation load was increased from 50 to 100 N. For the residual ridges on the loading side, the direction of the forces for all attachments changed to downward with increasing installation load. Furthermore, the yaw Euler angle increased with increasing installation load for the magnetic attachment. Subject to the limitations of this study, the use of any installation load greater than 0 N is recommended for the installation of ball and Locator attachments on a denture base. Regarding magnetic attachments, our results also recommend installation on a denture base using any installation load greater than 0 N, and suggest that the resultant force acting on the implant can be decreased by increasing the installation load; however, a large installation load of 100 N should be avoided when installing the attachment on the denture base to avoid increasing the denture movement. © 2014 by the American College of Prosthodontists.

  7. Wear resistance of a modified polymethyl methacrylate artificial tooth compared to five commercially available artificial tooth materials.

    PubMed

    Kamonwanon, Pranithida; Yodmongkol, Sirasa; Chantarachindawong, Rojcharin; Thaweeboon, Sroisiri; Thaweeboon, Boonyanit; Srikhirin, Toemsak

    2015-08-01

    Wear resistance is a limitation of artificial denture teeth. Improving the wear resistance of conventional artificial denture teeth is of value to prosthodontic patients. The purpose of this in vitro study was to evaluate the wear resistance and hardness of modified polymethyl methacrylate artificial denture teeth compared to 5 commercially available artificial tooth materials. This study evaluated 180 artificial denture teeth (6 groups) that included 3 groups of conventional artificial teeth (MajorDent, Cosmo HXL, and Gnathostar), 2 groups of composite resin artificial teeth (Endura and SR Orthosit PE), and 1 group of modified surface artificial teeth. The flattened buccal surface of each tooth (n=15) was prepared for investigation with the Vickers hardness test and the elucidate wear test (n=15) by using a brushing machine. Each group was loaded for 18,000 cycles, at 2 N, and 150 rpm. The wear value was identified with a profilometer. The data were statistically analyzed by using 1-way ANOVA and post hoc Turkey honestly significant difference tests (α=.001). The tribologies were observed under a scanning electron microscope, and the cytotoxicities were evaluated by MTT assay. The Vickers hardnesses ranged from 28.48 to 39.36. The wear depths and worn surface area values ranged from 1.12 to 10.79 μm and from 6.74 to 161.95 μm(2). The data revealed that the modified artificial denture teeth were significantly harder and exhibited significantly higher wear resistance than did the conventional artificial teeth (P<.001). The scanning electron microscopic images revealed cross sections of the conventional artificial denture teeth with intensively worn surface areas after brushing. The cytotoxicity test revealed 97.85% cell viability, which indicates the nontoxicity of the modified surface of this material. Within the limitations of this study, the polymethyl methacrylate modified surface artificial denture teeth was not significantly different from that of the composite resin artificial denture teeth, with the exceptions that the surface was harder and more wear resistant. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Preventive effects of a phospholipid polymer coating on PMMA on biofilm formation by oral streptococci

    NASA Astrophysics Data System (ADS)

    Shibata, Yukie; Yamashita, Yoshihisa; Tsuru, Kanji; Ishihara, Kazuhiko; Fukazawa, Kyoko; Ishikawa, Kunio

    2016-12-01

    The regulation of biofilm formation on dental materials such as denture bases is key to oral health. Recently, a biocompatible phospholipid polymer, poly(2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate) (PMB) coating, was reported to inhibit sucrose-dependent biofilm formation by Streptococcus mutans, a cariogenic bacterium, on the surface of poly(methyl methacrylate) (PMMA) denture bases. However, S. mutans is a minor component of the oral microbiome and does not play an important role in biofilm formation in the absence of sucrose. Other, more predominant oral streptococci must play an indispensable role in sucrose-independent biofilm formation. In the present study, the effect of PMB coating on PMMA was evaluated using various oral streptococci that are known to be initial colonizers during biofilm formation on tooth surfaces. PMB coating on PMMA drastically reduced sucrose-dependent tight biofilm formation by two cariogenic bacteria (S. mutans and Streptococcus sobrinus), among seven tested oral streptococci, as described previously [N. Takahashi, F. Iwasa, Y. Inoue, H. Morisaki, K. Ishihara, K. Baba, J. Prosthet. Dent. 112 (2014) 194-203]. Streptococci other than S. mutans and S. sobrinus did not exhibit tight biofilm formation even in the presence of sucrose. On the other hand, all seven species of oral streptococci exhibited distinctly reduced glucose-dependent soft biofilm retention on PMB-coated PMMA. We conclude that PMB coating on PMMA surfaces inhibits biofilm attachment by initial colonizer oral streptococci, even in the absence of sucrose, indicating that PMB coating may help maintain clean conditions on PMMA surfaces in the oral cavity.

  9. Improvement of baking quality traits through a diverse soft winter wheat population

    USDA-ARS?s Scientific Manuscript database

    Breeding baking quality improvements into soft winter wheat (SWW) entails crossing lines based on quality traits, assessing new lines, and repeating several times as little is known about the genetics of these traits. Previous research on SWW baking quality focused on quantitative trait locus and ge...

  10. Corrected Article: Simulation and observation of line-slip structures in columnar structures of soft spheres [Phys. Rev. E 96, 012610 (2017)

    NASA Astrophysics Data System (ADS)

    Winkelmann, J.; Haffner, B.; Weaire, D.; Mughal, A.; Hutzler, S.

    2017-07-01

    We present the computed phase diagram of columnar structures of soft spheres under pressure, of which the main feature is the appearance and disappearance of line slips, the shearing of adjacent spirals, as pressure is increased. A comparable experimental observation is made on a column of bubbles under forced drainage, clearly exhibiting the expected line slip.

  11. Malignant transformation of guinea pig cells after exposure to ultraviolet-irradiated guinea pig cytomegalovirus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isom, H.C.; Mummaw, J.; Kreider, J.W.

    1983-04-30

    Guinea pig cells were malignantly transformed in vitro by ultraviolet (uv)-irradiated guinea pig cytomegalovirus (GPCMV). When guinea pig hepatocyte monolayers were infected with uv-irradiated GPCMV, three continuous epithelioid cell lines which grew in soft agarose were established. Two independently derived GPCMV-transformed liver cells and a cell line derived from a soft agarose clone of one of these lines induced invasive tumors when inoculated subcutaneously or intraperitoneally into nude mice. The tumors were sarcomas possibly derived from hepatic stroma or sinusoid. Transformed cell lines were also established after infection of guinea pig hepatocyte monolayers with human cytomegalovirus (HCMV) or simian virusmore » 40 (SV40). These cell lines also formed colonies in soft agarose and induced sarcomas in nude mice. It is concluded that (i) GPCMV can malignantly transform guinea pig cells; (ii) cloning of GPCMV-transformed cells in soft agarose produced cells that induced tumors with a shorter latency period but with no alteration in growth rate or final tumor size; and (iii) the tumors produced by GPCMV-and HCMV-transformed guinea pig cells were more similar to each other in growth rate than to those induced by SV40-transformed guinea pig cells.« less

  12. PMMA denture base material enhancement: a review of fiber, filler, and nanofiller addition

    PubMed Central

    Gad, Mohammed M; Fouda, Shaimaa M; Al-Harbi, Fahad A; Näpänkangas, Ritva; Raustia, Aune

    2017-01-01

    This paper reviews acrylic denture base resin enhancement during the past few decades. Specific attention is given to the effect of fiber, filler, and nanofiller addition on poly(methyl methacrylate) (PMMA) properties. The review is based on scientific reviews, papers, and abstracts, as well as studies concerning the effect of additives, fibers, fillers, and reinforcement materials on PMMA, published between 1974 and 2016. Many studies have reported improvement of PMMA denture base material with the addition of fillers, fibers, nanofiller, and hybrid reinforcement. However, most of the studies were limited to in vitro investigations without bioactivity and clinical implications. Considering the findings of the review, there is no ideal denture base material, but the properties of PMMA could be improved with some modifications, especially with silanized nanoparticle addition and a hybrid reinforcement system. PMID:28553115

  13. [The reasons why 13 MK1 attachment were re-fabricated and some methods for improvement].

    PubMed

    Wu, Zhi-hong; Zhang, Xue-jun; Zhao, Jun

    2013-12-01

    To investigate the reasons why 13 MK1 attachment were re-fabricated and to suggest some improvement methods. Mechanics and denture production technology were reviewed in 13 cases with MK1 attachment denture to determine the causes of failure. In some cases, MK1 attachments were poorly designed, while in other cases problems were found during denture design and production process due to limited experiences at the initial stage. MK1 attachments were re-done based on the specific cause and the outcome was good after 1-1.5 years of follow-up. When using MK1 attachment, prosthodontists should be familiar with the characteristics and indications of MK1 attachment. Meanwhile, we should strengthen doctor-patient communication and follow up patients timely to improve the success rate of MK1 attached denture repair.

  14. Improved Prefrontal Activity and Chewing Performance as Function of Wearing Denture in Partially Edentulous Elderly Individuals: Functional Near-Infrared Spectroscopy Study

    PubMed Central

    Kamiya, Kazunobu; Narita, Noriyuki; Iwaki, Sunao

    2016-01-01

    The purpose of this study was to elucidate the effects of wearing a denture on prefrontal activity during chewing performance. We specifically examined that activity in 12 elderly edentulous subjects [63.1±6.1 years old (mean ± SD)] and 12 young healthy controls (22.1±2.3 years old) using functional near-infrared spectroscopy (fNIRS) in order to evaluate the quality of prefrontal functionality during chewing performance under the conditions of wearing a denture and tooth loss, and then compared the findings with those of young healthy controls. fNIRS and electromyography were used simultaneously to detect prefrontal and masticatory muscle activities during chewing, while occlusal force and masticatory score were also examined by use of a food intake questionnaire. A significant increase in prefrontal activity was observed during chewing while wearing a denture, which was accompanied by increased masticatory muscle activity, occlusal force, and masticatory score, as compared with the tooth loss condition. Prefrontal activation during chewing while wearing a denture in the elderly subjects was not much different from that in the young controls. In contrast, tooth loss in the elderly group resulted in marked prefrontal deactivation, accompanied by decreased masticatory muscle activity, occlusal force, and masticatory score, as compared with the young controls. We concluded that intrinsic prefrontal activation during chewing with a denture may prevent prefrontal depression induced by tooth loss in elderly edentulous patients. PMID:27362255

  15. Estimate of Impact on the Oral Health-Related Quality of Life of Older Thai People by the Provision of Dentures through the Royal Project.

    PubMed

    Srisilapanan, Patcharawan; Korwanich, Narumanas; Jienmaneechotchai, Sutha; Dalodom, Supranee; Veerachai, Nontalee; Vejvitee, Warangkana; Roseman, Jeffrey

    2016-01-01

    Purpose. To estimate the impact of the provision of dentures to Thai older people by the Royal Project on their oral health-related quality of life. Methods. A purposive cross-sectional study of a sample of 812 subjects was conducted. The Oral Impacts on Daily Performances (OIDP) measure was used to assess the oral health-related quality of life. Results. Four groups of older people with different tooth types were studied. 216 (26.6%) had natural teeth (NT). 189 (23.3%) had natural and replaced teeth (NRT). 167 (20.6%) had below the minimum number of teeth but had no dentures (Edent) and 240 were edentate with complete dentures provided by the Royal Project (ECD) (29.6%). Overall, 36.5% had at least one oral impact. Eating was the most affected oral impact. When compared to the group with natural teeth (NT), the Edent group was significantly more likely to report having impacts on eating OR = 6.5 (3.9-10.9), speaking clearly OR = 43.7 (12.7-15.07), emotional stability OR = 16.5 (6.0-45.6), and social contacts OR = 4.6 (2.2-9.5) (p < 0.001). Conclusion. Those who are edentulous are much more likely to have an oral impact on their daily performances than those provided dentures. Provision of dentures may lead to improvement of considerable oral impacts.

  16. Adhesion properties in systems of laminated pigmented polymers, carbon-graphite fiber composite framework and titanium surfaces in implant suprastructures.

    PubMed

    Segerström, Susanna; Ruyter, I Eystein

    2009-09-01

    For long-term stability the adhering interfaces of an implant-retained supraconstruction of titanium/carbon-graphite fiber-reinforced (CGFR) polymer/opaquer layer/denture base polymer/denture teeth must function as a unity. The aim was to evaluate adhesion of CGFR polymer to a titanium surface or CGFR polymer to two different opaquer layers/with two denture base polymers. Titanium plates were surface-treated and silanized and combined with a bolt of CGFR polymer or denture base polymer (Probase Hot). Heat-polymerized plates of CGFR polymer (47 wt% fiber) based on poly(methyl methacrylate) and a copolymer matrix were treated with an opaquer (Sinfony or Ropak) before a denture base polymer bolt was attached (Probase Hot or Lucitone 199). All specimens were heat-polymerized, water saturated (200 days) and thermally cycled (5000 cycles, 5/55 degrees C) before shear bond testing. Silicatized titanium surfaces gave higher bond strength to CGFR polymer (16.2+/-2.34 and 18.6+/-1.32) MPa and cohesive fracture than a sandblasted surface (5.9+/-2.11) MPa where the fracture was adhesive. The opaquer Sinfony gave higher adhesion values and mainly cohesive fractures than the opaquer Ropak. Different surface treatments (roughened or polished) of the CGFR polymer had no effect on bond strength. The fracture surfaces of silicatized titanium/CGFR polymer/opaquer layer (Sinfony)/denture base polymers were mainly cohesive. A combination of these materials in an implant-retained supraconstruction is promising for in vivo evaluation.

  17. Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.

    PubMed

    Bernhart, Gunda; Koob, Andreas; Schmitter, Marc; Gabbert, Olaf; Stober, Thomas; Rammelsberg, Peter

    2012-08-01

    The objective of this retrospective study was to compare biological and technical complications of implant-supported and tooth-implant-supported double crown-retained dentures (DCRDs) with those of tooth-supported DCRDs. Sixty-three DCRDs were monitored. One study group included 16 prostheses with a combination of implants and natural teeth as double crowns (ti group), whereas in the second study group, 19 dentures were retained exclusively on implants (ii group); a third study group with 28 exclusively tooth-supported dentures served as controls (tt group). Tooth loss, implant failure, and technical complications (loss of retention of primary crown, abutment screw loosening, loss of facing, fracture of resin denture teeth and fracture of saddle resin) were analysed. During the observation period of 24 months, no implants or teeth were lost in the ti group and three technical complications were recorded. In the ii group, two implants were lost, two cases of peri-implantitis occurred and four technical complications were observed. In the tt group, two cases of tooth loss and seven technical complications were observed. At the time of the last examination, all prostheses of the ti group and the ii group were functional. Patients of these two study groups reported high satisfaction with both function and aesthetics with no significant difference between the two groups. Treatment with DCRDs showed comparable results in the three study groups. The 2-year results indicate that double crowns can be recommended for implant and combined tooth-implant-retained dentures.

  18. Rotational movements of mandibular two-implant overdentures.

    PubMed

    Kimoto, Suguru; Pan, Shaoxia; Drolet, Nicolas; Feine, Jocelyne S

    2009-08-01

    Clinicians have reported that their patients complain that their mandibular two-implant overdentures (IOD) rotate. Therefore, we studied the frequency and severity of rotation of IODs with two-ball attachments, how rotation may influence perceived satisfaction ratings of chewing ability, and the factors that are involved in the rotation of IODs. Seventy-nine participants were recruited and asked to rate their general satisfaction of their IODs, as well as their ability to chew foods, the existence of any mandibular denture rotation, and to what degree denture rotation bothered them. Data on participant sociodemographic, anatomical, and prosthesis characteristics were also collected. Student's t-test and logistic regression analyses were performed to analyze the differences between participants who did (R group) and did not report (NR group) denture rotation. Thirty-seven of 79 participants were aware of rotational movement in their IODs. These patients were significantly less satisfied with their chewing ability than those who felt no rotation (69.1 mm R group vs. 82.9 mm), and discomfort caused by the rotation bothered them moderately (39/100 mm). The multivariate logistic regression analysis revealed that the arrangement of the anterior teeth and the length of the denture are significantly associated with awareness of denture rotation. Thirty-eight percent in the R group and 31% in the NR group had non-scheduled visits. Rotational movement with a mandibular two-IOD has a negative effect on perceived chewing ability and is associated with anterior tooth arrangement and denture length.

  19. Contour of lingual surface in lower complete denture formed by polished surface impression.

    PubMed

    Heo, Yu-Ri; Kim, Hee-Jung; Son, Mee-Kyoung; Chung, Chae-Heon

    2016-12-01

    The aim of this study was to analyze the shapes of lingual polished surfaces in lower complete dentures formed by polished surface impressions and to provide reference data for use when manufacturing edentulous trays and lower complete dentures. Twenty-six patients with mandibular edentulism were studied. After lower wax dentures were fabricated, wax was removed from the lingual side of the wax denture and a lingual polished surface impression was obtained with tissue conditioner. The definitive denture was scanned with a three-dimensional scanner, and scanned images were obtained. At the cross-sections of the lingual frenum, lateral incisors, first premolars, first molars, and anterior border of the retromolar pads, three points were marked and eight measurements were taken. The Kruskal-Wallis test and a post hoc analysis with the Mann-Whitney test were performed. Each patient showed similar values for the same areas on the left and right sides without a statistically significant difference. The height of the contour of the lingual polished surface at the lingual frenum was halfway between the occlusal plane and lingual border, it moved gradually in a downward direction. The angle from the occlusal plane to the height of the contour of the lingual polished surface was increased as it progressed from the lingual frenum towards the retromolar pads. The shape of the mandibular lingual polished surface was convex at the lingual frenum, lateral incisors and gradually flattened towards the first molars and retromolar pads.

  20. Epidemiological survey on edentulousness.

    PubMed

    Reddy, N Simhachalam; Reddy, Nallala Amarendra; Narendra, R; Reddy, Sashi Deepth

    2012-07-01

    India has a large geriatric population of 77 millions, comprising 7.7% of its total population. One of the major handicaps in the elderly is loss of teeth, affecting their mastication, dietary intake and nutritional status. The present study was planned to assess the level of edentulousness, cause of edentulousness, denture wearing and denture needs of the middle and elderly in the society and study was correlated between habits and socioeconomic variables, diet and body mass index (BMI). A total of 500 subjects (random sampling) from dental outpatient were studied. A prepared questionnaire was developed, explained, interviewed and questions were filled personally. The level of edentulousness was found to be high in the subjects with low socioeconomic status and in advancing age with no significant difference between male and females. Another finding was very low level of denture wearing of 62% needing complete denture and partial denture only 10.4% of subjects wearing dentures. Mixed diet population had higher level of edentulousness compared with vegetarians. The BMI was correlated with level of edentulousness. The study clearly showed that there is lack of dental awareness, so dental education and motivation in very important. The study concludes that the need for prosthodontics care will increase due to the increase in life span. This study is clinically significant with regard to knowing the root cause of edentulism, either partial or complete. Out of 62% tooth loss, dental caries (37.4%) topped the cause for tooth loss followed by combination of dental caries and periodontal disease (12.2%).

  1. The Versatility of 980 nm Diode Laser in Dentistry: A Case Series

    PubMed Central

    Derikvand, Nahid; Chinipardaz, Zahra; Ghasemi, Sara; Chiniforush, Nasim

    2016-01-01

    Introduction: Laser surgery has been considered a popular alternative over conventional modalities in dentistry during the last few years. Among different types of lasers, diode lasers have gained special attention in oral soft tissue surgery. Case Reports: Five patients were referred to a private office. After careful evaluation of medical history and oral examination, oral diagnosis and treatment plan of each patient was established as follows: (1) A 21-year-old female with ankyloglossia (tongue-tie); (2) A 65-year-old female with a poor denture fit needing vestibuloplasty and frenectomy; (3) A 10-year-old male patient with pigmented gingiva in mandible and maxilla; (4) A 14-year-old female needing exposure of maxillary right canine for bracket bonding; and (5) A 25-year-old female patient who has a gingival maxillary frenum with a nodule. The treatment plan for all the patients was laser surgery with diode laser at 980 nm, in continuous mode. Results: All the patients experienced normal healing process with no postoperative complications. Favorable outcomes of laser surgery were observed on follow-up sessions. Conclusion: Considering the versatility of the 980 nm diode laser in oral soft tissue surgeries and the advantages of laser surgery, this study suggests the use of 980 nm diode laser in this regard. PMID:28144444

  2. The Versatility of 980 nm Diode Laser in Dentistry: A Case Series.

    PubMed

    Derikvand, Nahid; Chinipardaz, Zahra; Ghasemi, Sara; Chiniforush, Nasim

    2016-01-01

    Introduction: Laser surgery has been considered a popular alternative over conventional modalities in dentistry during the last few years. Among different types of lasers, diode lasers have gained special attention in oral soft tissue surgery. Case Reports: Five patients were referred to a private office. After careful evaluation of medical history and oral examination, oral diagnosis and treatment plan of each patient was established as follows: (1) A 21-year-old female with ankyloglossia (tongue-tie); (2) A 65-year-old female with a poor denture fit needing vestibuloplasty and frenectomy; (3) A 10-year-old male patient with pigmented gingiva in mandible and maxilla; (4) A 14-year-old female needing exposure of maxillary right canine for bracket bonding; and (5) A 25-year-old female patient who has a gingival maxillary frenum with a nodule. The treatment plan for all the patients was laser surgery with diode laser at 980 nm, in continuous mode. Results: All the patients experienced normal healing process with no postoperative complications. Favorable outcomes of laser surgery were observed on follow-up sessions. Conclusion: Considering the versatility of the 980 nm diode laser in oral soft tissue surgeries and the advantages of laser surgery, this study suggests the use of 980 nm diode laser in this regard.

  3. Cone Beam Computed Tomography Analysis in 3D Position of Maxillary Denture

    PubMed Central

    Jia, Ying; Yang, Hua; Li, Ping; Xiong, Jiangyan; Chen, Bo

    2017-01-01

    Abstract The dynamic correlation between teeth and denture morphology as well as the morphological positions needs to be explored. Methodology 63 adult patients with skeletal class III malocclusions that met the inclusion criteria were enrolled and imaged with Cone Beam Computed Tomography (CBCT), and Digital Imaging and Communications in Medicine (DICOM) data were collected. The torque angle and axial inclination were measured and analyzed for the corona, root, and entire body of every tooth on the maxilla. Results There is a statistically significant difference between the coronal axial inclination/coronal torque angle for the skeletal class III malocclusion cases and Andrew’s six keys of occlusion. On the sagittal plane of the maxillary denture (except that the secondary molar is inclined medial-distally), the remaining teeth are inclined towards the labia with slightly larger angles compared to the normal occlusion. In the coronal direction, the maxillary anterior teeth tend to have a corona that inclines medial-distally, whereas the posterior teeth have a buccal inclination compared to the normal occlusion. Conclusion Sagittal and transversal compensations prevail in maxillary dentures; for the camouflaged treatment design for skeletal class III, there is limited scope of sagittal and transversal movements on the maxillary denture. PMID:29104942

  4. Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient

    PubMed Central

    Ha, Seung-Ryong; Song, Seung-Il; Hong, Seong-Tae; Kim, Gy-Young

    2012-01-01

    Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar® is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar® was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar® system in a mandibular edentulous patient. PMID:23236580

  5. The role of single immediate loading implant in long Class IV Kennedy mandibular partial denture.

    PubMed

    Mohamed, Gehan F; El Sawy, Amal A

    2012-10-01

    The treatment of long-span Kennedy class IV considers a prosthodontic challenge. This study evaluated the integrity of principle abutments in long Kennedy class IV clinically and radiographically, when rehabilitated with conventional metallic partial denture as a control group and mandibular partial overdentures supported with single immediately loaded implant in symphyseal as a study group. Twelve male patients were divided randomly allotted into two equal groups. First group patients received removable metallic partial denture, whereas in the second group, patients received partial overdentures supported with single immediately loaded implant in symphyseal region. The partial dentures design in both groups was the same. Long-cone paralleling technique and transmission densitometer were used at the time of denture insertion, 3, 6, and 12 months. Gingival index, bone loss, and optical density were measured for principle abutments during the follow-up. A significant reduction in bone loss and density were detected in group II comparing with group I. Gingival index had no significant change (p-value < 0.05). A single symphyseal implant in long span class IV Kennedy can play a pivotal role to improve the integrity of the principle abutments and alveolar bone support. © 2010 Wiley Periodicals, Inc.

  6. Maximum bite force in elderly indigenous and non-indigenous denture wearers.

    PubMed

    Borie, Eduardo; Orsi, Iara A; Fuentes, Ramón; Beltrán, Víctor; Navarro, Pablo; Pareja, Felipe; Raimundo, Lariça B

    2014-01-01

    The aim of this study was to compare the measures of maximum bite force (MBF) in elderly edentulous indigenous (Mapuche) and non-indigenous individuals with new complete dentures at two different measuring times. A sample of 100 elderly subjects was divided into two groups: 50 indigenous and 50 non-indigenous, each including 25 females and 25 males. All individuals were totally edentulous, with new maxillary and mandibular removable complete dentures. Measurements were taken at the time of new prosthesis placement and after 1 month of use. Subjects were asked to perform with maximum effort three bites per side at maximum intercuspidation, with a rest time of 2 minutes in between. Statistics were analyzed with Student 's t-test. The MBF values were significantly higher in indigenous than non-indigenous subjects. Force after 1 month of wearing the new prosthesis was significantly higher than at the time of new prosthesis placement. No significant difference was found between sides. Elderly indigenous complete denture wearers had the greatest MBF values. Denture wearers were observed to undergo an adaptation process to the new prosthesis, with MBF increasing considerably after one month of use.

  7. Space Telescope and Optical Reverberation Mapping Project. VII. Understanding the Ultraviolet Anomaly in NGC 5548 with X-Ray Spectroscopy

    NASA Astrophysics Data System (ADS)

    Mathur, S.; Gupta, A.; Page, K.; Pogge, R. W.; Krongold, Y.; Goad, M. R.; Adams, S. M.; Anderson, M. D.; Arévalo, P.; Barth, A. J.; Bazhaw, C.; Beatty, T. G.; Bentz, M. C.; Bigley, A.; Bisogni, S.; Borman, G. A.; Boroson, T. A.; Bottorff, M. C.; Brandt, W. N.; Breeveld, A. A.; Brown, J. E.; Brown, J. S.; Cackett, E. M.; Canalizo, G.; Carini, M. T.; Clubb, K. I.; Comerford, J. M.; Coker, C. T.; Corsini, E. M.; Crenshaw, D. M.; Croft, S.; Croxall, K. V.; Dalla Bontà, E.; Deason, A. J.; Denney, K. D.; De Lorenzo-Cáceres, A.; De Rosa, G.; Dietrich, M.; Edelson, R.; Ely, J.; Eracleous, M.; Evans, P. A.; Fausnaugh, M. M.; Ferland, G. J.; Filippenko, A. V.; Flatland, K.; Fox, O. D.; Gates, E. L.; Gehrels, N.; Geier, S.; Gelbord, J. M.; Gorjian, V.; Greene, J. E.; Grier, C. J.; Grupe, D.; Hall, P. B.; Henderson, C. B.; Hicks, S.; Holmbeck, E.; Holoien, T. W.-S.; Horenstein, D.; Horne, Keith; Hutchison, T.; Im, M.; Jensen, J. J.; Johnson, C. A.; Joner, M. D.; Jones, J.; Kaastra, J.; Kaspi, S.; Kelly, B. C.; Kelly, P. L.; Kennea, J. A.; Kim, M.; Kim, S.; Kim, S. C.; King, A.; Klimanov, S. A.; Kochanek, C. S.; Korista, K. T.; Kriss, G. A.; Lau, M. W.; Lee, J. C.; Leonard, D. C.; Li, M.; Lira, P.; Ma, Z.; MacInnis, F.; Manne-Nicholas, E. R.; Malkan, M. A.; Mauerhan, J. C.; McGurk, R.; McHardy, I. M.; Montouri, C.; Morelli, L.; Mosquera, A.; Mudd, D.; Muller-Sanchez, F.; Musso, R.; Nazarov, S. V.; Netzer, H.; Nguyen, M. L.; Norris, R. P.; Nousek, J. A.; Ochner, P.; Okhmat, D. N.; Ou-Yang, B.; Pancoast, A.; Papadakis, I.; Parks, J. R.; Pei, L.; Peterson, B. M.; Pizzella, A.; Poleski, R.; Pott, J.-U.; Rafter, S. E.; Rix, H.-W.; Runnoe, J.; Saylor, D. A.; Schimoia, J. S.; Schnülle, K.; Sergeev, S. G.; Shappee, B. J.; Shivvers, I.; Siegel, M.; Simonian, G. V.; Siviero, A.; Skielboe, A.; Somers, G.; Spencer, M.; Starkey, D.; Stevens, D. J.; Sung, H.-I.; Tayar, J.; Tejos, N.; Turner, C. S.; Uttley, P.; Van Saders, J.; Vestergaard, M.; Vican, L.; Villanueva, S., Jr.; Villforth, C.; Weiss, Y.; Woo, J.-H.; Yan, H.; Young, S.; Yuk, H.; Zheng, W.; Zhu, W.; Zu, Y.

    2017-09-01

    During the Space Telescope and Optical Reverberation Mapping Project observations of NGC 5548, the continuum and emission-line variability became decorrelated during the second half of the six-month-long observing campaign. Here we present Swift and Chandra X-ray spectra of NGC 5548 obtained as part of the campaign. The Swift spectra show that excess flux (relative to a power-law continuum) in the soft X-ray band appears before the start of the anomalous emission-line behavior, peaks during the period of the anomaly, and then declines. This is a model-independent result suggesting that the soft excess is related to the anomaly. We divide the Swift data into on- and off-anomaly spectra to characterize the soft excess via spectral fitting. The cause of the spectral differences is likely due to a change in the intrinsic spectrum rather than to variable obscuration or partial covering. The Chandra spectra have lower signal-to-noise ratios, but are consistent with the Swift data. Our preferred model of the soft excess is emission from an optically thick, warm Comptonizing corona, the effective optical depth of which increases during the anomaly. This model simultaneously explains all three observations: the UV emission-line flux decrease, the soft-excess increase, and the emission-line anomaly.

  8. [A study on the mechanical behaviors of abutment teeth with various coping designs under overdenture].

    PubMed

    Vang, M S; Cho, J H

    1990-04-01

    An overdenture is a complete denture supported by both soft tissue and a few remaining natural teeth. The purpose of this study was to analyze the stress distribution of the teeth and supporting structures when various type of coping under overdenture was applied. The analysis was conducted by using the finite element method and changing the condition such as the direction of the load, the shape of coping on the abutment: The model included overdenture copings, abutment tooth and supporting structures. The results of analysis were as follows: 1. The short dome coping showed well distribution of stress. 2. The dome shaped design produced higher stress distribution than square and inclined plane design. 3. As the height of copings on the abutment was increased, the displacements increased. 4. The magnitude and direction of the abutment displacements were influenced by the direction of load application.

  9. 21 CFR 872.3570 - OTC denture repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... powder and liquid glues, that is intended to be applied permanently to a denture to mend cracks or breaks. The device may be available for purchase over-the counter. (b) Classification. Class II. The special...

  10. 21 CFR 872.3570 - OTC denture repair kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... powder and liquid glues, that is intended to be applied permanently to a denture to mend cracks or breaks. The device may be available for purchase over-the counter. (b) Classification. Class II. The special...

  11. 21 CFR 872.3570 - OTC denture repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... powder and liquid glues, that is intended to be applied permanently to a denture to mend cracks or breaks. The device may be available for purchase over-the counter. (b) Classification. Class II. The special...

  12. 21 CFR 872.3570 - OTC denture repair kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... powder and liquid glues, that is intended to be applied permanently to a denture to mend cracks or breaks. The device may be available for purchase over-the counter. (b) Classification. Class II. The special...

  13. 21 CFR 872.3570 - OTC denture repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... powder and liquid glues, that is intended to be applied permanently to a denture to mend cracks or breaks. The device may be available for purchase over-the counter. (b) Classification. Class II. The special...

  14. Final-impression techniques and materials for making complete and removable partial dentures.

    PubMed

    Jayaraman, Srinivasan; Singh, Balendra P; Ramanathan, Balasubramanian; Pazhaniappan Pillai, Murukan; MacDonald, Laura; Kirubakaran, Richard

    2018-04-04

    Edentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures (CD) and removable partial dentures (RPD) using different techniques and materials. Applying the correct impression technique and material, based on an individual's oral condition, improves the quality of the prosthesis, which may improve quality of life. To assess the effects of different final-impression techniques and materials used to make complete dentures, for retention, stability, comfort, and quality of life in completely edentulous people.To assess the effects of different final-impression techniques and materials used to make removable partial dentures, for stability, comfort, overextension, and quality of life in partially edentulous people. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 November 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Register of Studies, to 22 November 2017), MEDLINE Ovid (1946 to 22 November 2017), and Embase Ovid (21 December 2015 to 22 November 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on language or publication status when searching the electronic databases, however the search of Embase was restricted by date due to the Cochrane Centralised Search Project to identify all clinical trials and add them to CENTRAL. We included randomised controlled trials (RCTs) comparing different final-impression techniques and materials for treating people with complete dentures (CD) and removable partial dentures (RPD). For CD, we included trials that compared different materials or different techniques or both. In RPD for tooth-supported conditions, we included trials comparing the same material and different techniques, or different materials and the same technique. In tooth- and tissue-supported RPD, we included trials comparing the same material and different dual-impression techniques, and different materials with different dual-impression techniques. Two review authors independently, and in duplicate, screened studies for eligibility, extracted data, and assessed the risk of bias for each included trial. We expressed results as risk ratios (RR) for dichotomous outcomes, and as mean differences (MD) or standardised mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CI), using the random-effects model. We constructed 'Summary of findings' tables for the main comparisons and outcomes (participant-reported oral health-related quality of life, quality of the denture, and denture border adjustments). We included nine studies in this review. Eight studies involved 485 participants with CD. We assessed six of the studies to be at high risk of bias, and two to be at low risk of bias. We judged one study on RPD with 72 randomised participants to be at high risk of bias.Overall, the quality of the evidence for each comparison and outcome was either low or very low, therefore, results should be interpreted with caution, as future research is likely to change the findings.Complete denturesTwo studies compared the same material and different techniques (one study contributed data to a secondary outcome only); two studies compared the same technique and different materials; and four studies compared different materials and techniques.One study (10 participants) evaluated two stage-two step, Biofunctional Prosthetic system (BPS) using additional silicone elastomer compared to conventional methods, and found no evidence of a clear difference for oral health-related quality of life, or quality of the dentures (denture satisfaction). The study reported that BPS required fewer adjustments. We assessed the quality of the evidence as very low.One study (27 participants) compared selective pressure final-impression technique using wax versus polysulfide elastomeric (rubber) material. The study did not measure quality of life or dentures, and found no evidence of a clear difference between interventions in the need for adjustments (RR 0.81, 95% CI 0.38 to 1.70). We assessed the quality of the evidence as very low.One study compared two stage-two step final impression with alginate versus silicone elastomer. Oral health-related quality of life measured by the OHIP-EDENT seemed to be better with silicone (MD 7.20, 95% CI 2.71 to 11.69; 144 participants). The study found no clear differences in participant-reported quality of the denture (comfort) after a two-week 'confirmation' period, but reported that silicone was better for stability and chewing efficiency. We assessed the quality of the evidence as low.Three studies compared single-stage impressions with alginate versus two stage-two step with elastomer (silicone, polysulfide, or polyether) impressions. There was no evidence of a clear difference in the OHIP-EDENT at one month (MD 0.05, 95% CI -2.37 to 2.47; two studies, 98 participants). There was no evidence of a clear difference in participant-rated general satisfaction with dentures at six months (MD 0.00, 95% CI -8.23 to 8.23; one study, 105 participants). We assessed the quality of the evidence as very low.One study compared single-stage alginate versus two stage-two step using zinc-oxide eugenol, and found no evidence of a clear difference in OHIP-EDENT (MD 0.50, 95% CI -2.67 to 3.67; 39 participants), or general satisfaction (RR 3.15, 95% CI 0.14 to 72.88; 39 participants) at six months. We assessed the quality of the evidence as very low.Removable partial denturesOne study randomised 72 participants and compared altered-cast technique versus one-piece cast technique. The study did not measure quality of life, but reported that most participants were satisfied with the dentures and there was no evidence of any clear difference between groups for general satisfaction at one-year follow-up (low-quality evidence). There was no evidence of a clear difference in number of intaglio adjustments at one year (RR 1.43, 95% CI 0.61 to 3.34) (very low-quality evidence). We conclude that there is no clear evidence that one technique or material has a substantial advantage over another for making complete dentures and removable partial dentures. Available evidence for the relative benefits of different denture fabrication techniques and final-impression materials is limited and is of low or very low quality. More high-quality RCTs are required.

  15. A simplified method to reduce prosthetic misfit for a screw-retained, implant-supported complete denture using a luting technique and laser welding.

    PubMed

    Longoni, Salvatore; Sartori, Matteo; Davide, Roberto

    2004-06-01

    An important aim of implant-supported prostheses is to achieve a passive fit of the framework with the abutments to limit the amount of stress transfer to the bone-implant interface. An efficient and standardized technique is proposed. A definitive screw-retained, implant-supported complete denture was fabricated for an immediately loaded provisional screw-retained implant-supported complete denture. Precise fit was achieved by the use of industrial titanium components and the passivity, by an intraoral luting sequence and laser welding.

  16. Mechanical properties and cytotoxicity of experimental soft lining materials based on urethane acrylate oligomers.

    PubMed

    Kanie, Takahito; Tomita, Koichi; Tokuda, Masayuki; Arikawa, Hiroyuki; Fujii, Koichi; Ban, Seiji

    2009-07-01

    The purpose of this investigation was to determine whether experimental light-curing soft lining materials (ESLMs) based on commercially available urethane acrylate oligomers (UA-160TM, UV-3200B, UV-3500BA, and UV-3700B) are suitable for clinical use by measuring their viscosity, compressive modulus, Shore A hardness, tensile strength, adhesive strength, and cytotoxicity. The viscosities of the four ESLMs at 25 degrees C were 10.5 Pa.s, UV-3500BA; 144.0 Pa.s, UA-160TM; 328.8 Pa.s, UV-3700B; and 1079.7 Pa.s, UV-3200B. Polymerized UV-3700B was very soft, whereas the softness of the other ESLMs was similar to that of conventional soft lining materials. No significant difference in adhesive strength was observed between UV-3500BA and UV-3700B at 1 day and those at 12 months. Cytotoxicity was measured by a MTT-based assay using HeLa S3 and Ca9-22 cells. UV-3200B and UV-3700B oligomers and all four polymerized ESLMs showed cell viability over 95.2% (p < 0.05).

  17. Reinforcing effect of glass-fiber mesh on complete dentures in a test model with a simulated oral mucosa.

    PubMed

    Yu, Sang-Hui; Oh, Seunghan; Cho, Hye-Won; Bae, Ji-Myung

    2017-11-01

    Studies that evaluated the strength of complete dentures reinforced with glass-fiber mesh or metal mesh on a cast with a simulated oral mucosa are lacking. The purpose of this in vitro study was to compare the mechanical properties of maxillary complete dentures reinforced with glass-fiber mesh with those of metal mesh in a new test model, using a simulated oral mucosa. Complete dentures reinforced with 2 types of glass-fiber mesh, SES mesh (SES) and glass cloth (GC) and metal mesh (metal) were fabricated. Complete dentures without any reinforcement were prepared as a control (n=10). The complete dentures were located on a cast with a simulated oral mucosa, and a load was applied on the posterior artificial teeth bilaterally. The fracture load, elastic modulus, and toughness of a complete denture were measured using a universal testing machine at a crosshead speed of 5 mm/min. The fracture load and elastic modulus were analyzed using 1-way analysis of variance, and the toughness was analyzed with the Kruskal-Wallis test (α=.05). The Tukey multiple range test was used as a post hoc test. The fracture load and toughness of the SES group was significantly higher than that of the metal and control groups (P<.05) but not significantly different from that of the GC group. The elastic modulus of the metal group was significantly higher than that of the control group (P<.05), and no significant differences were observed in the SES and GC groups. Compared with the control group, the fracture load and toughness of the SES and GC groups were higher, while those of the metal group were not significantly different. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. General health, dental status and perceived dental treatment needs of an elderly population in Istanbul.

    PubMed

    Ozkan, Yasar; Ozcan, Mutlu; Kulak, Yasemin; Kazazoglu, Ender; Arikan, Ayla

    2011-03-01

    Comprehensive data on the oral health status and dental treatment needs of the elderly population in Turkey are deficient. This pilot study determined the general and dental health status, perceived medical and dental treatment needs of an elderly population dwelling in residential homes in Istanbul. Subjects at three different residential homes, namely one belonging to the state and two supported by foundations in Istanbul (N=121, female: 63 and male: 58) were involved in this study. A detailed questionnaire was prepared and dental examinations were conducted. Information was collected related to age, education levels, financial status, current physical functional status, general health, mental health, previous dental history, current dental status, oral hygiene practices and denture hygiene of these elderly people. The prevalence of edentulism, the presence and type of dental prostheses, dental and denture status and denture cleanliness were further evaluated. The three most prevalent reported general health problems were associated with genito-urinary problems (24%) followed by cardiovascular (18%) and respiratory problems (14%) varying significantly between genders, with males suffering more from cardiovascular problems than females (p < 0.05). Females showed significantly higher gastrointestinal and orthopaedic problems than males (p < 0.05). Females were more frequently edentulous than males but denture hygiene was significantly better in females than in males (p < 0.05). Brushing frequency did not significantly increase denture hygiene (p = 0.6). More than one-third of the subjects had not been to the dentist within the previous 5-10 years, mainly due to lack of demand, followed by the cost of the dental care and fear. More than two-thirds of denture-wearing subjects wore their dentures only during eating. There was significant perceived dental treatment and care need for the sample population of elderly studied. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  19. A selective medium for the isolation of Microbacterium species in oral cavities.

    PubMed

    Tsuzukibashi, Osamu; Uchibori, Satoshi; Kobayashi, Taira; Saito, Masanori; Umezawa, Koji; Ohta, Mitsuhiro; Shinozaki-Kuwahara, Noriko

    2015-09-01

    The genus Microbacterium has been isolated from the environment, dairy goods, and human clinical specimens. Although, in our previous studies, some Microbacterium species were infrequently detected in oral samples collected from humans, there is currently no report that these organisms, which are capable of causing serious systemic infections, were isolated from the human oral cavity. The aim of the present study was to develop a selective medium to isolate the representative Microbacterium species most frequently detected in human clinical specimens, and reveal the distribution of individual Microbacterium species in the oral cavity. The growth recoveries of representative Microbacterium species on the selective medium, designated as MSM, were sufficient. Moreover, the growth of other representative oral bacteria was markedly inhibited on the selective medium. The proportion of Microbacterium species in the saliva samples of 60 subjects, 20 of whom were removable denture wearers, was then examined. The proportion of these organisms was also examined in environmental samples obtained by swabbing 20 washstands. PCR primers were designed for representative Microbacterium species. The genus Microbacterium was detected in 45% of the saliva and denture plaque samples collected from the twenty removable denture wearers, but was absent in the saliva of the forty non-denture wearers. On the other hand, these organisms were detected in all environmental samples. The genus Microbacterium accounted for 0.00003%, 0.0001%, and 12.6% of the total cultivable bacteria number on the BHI medium in the saliva and denture plaque samples of removable denture wearers and in the environmental samples, respectively. The most predominant Microbacterium species in all positive samples was Microbacterium oxydans. These results indicated that the genus Microbacterium was not a part of the normal flora in the human oral cavity, except for subjects wearing dentures that were contaminated by the environment, and the selective medium, designated as MSM, was useful for isolating Microbacterium species, which are frequently encountered in human clinical specimens, from the various samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Use of Candida-specific chicken egg yolk antibodies to inhibit the adhering of Candida to denture base materials: prevention of denture stomatitis.

    PubMed

    Kamikawa, Yoshiaki; Fujisaki, Junichi; Nagayama, Tomohiro; Kawasaki, Kiyotsugu; Hirabayashi, Daisuke; Hamada, Tomofumi; Sakamoto, Ryoich; Mukai, Hiroshi; Sugihara, Kazumasa

    2016-09-01

    Polyclonal anti-Candida chicken egg yolk antibodies (anti-IgY) were used to investigate the prevention of adherence of Candida species to denture base material in vitro. Candida is a potential virulence factor that can cause systemic infection and even death in immunocompromised individuals. Because long-term antifungal treatment may lead to the emergence of drug-resistant strains, it is necessary to develop novel preventive measures and treatments for candidiasis. Three types of chicken egg yolk antibodies were used in this study: non-specific antibody (control IgY), Candida albicans-specific antibody (anti-C.a.IgY) and Candida glabrata-specific antibody (anti-C.g.IgY). A mixture of different dilutions of each antibody with a suspension of Candida species and denture base material was incubated for 3 h, and then the colony-forming units of Candida on the denture base material were counted. Compared with control IgY, anti-C.a.IgY and anti-C.g.IgY significantly inhibited the adherence of C. albicans, but anti-C.a.IgY tended to be more potent than anti-C.g.IgY. The adherence of C. glabrata was also inhibited significantly by anti-C.a.IgY and anti-C.g.IgY with almost equivalent potency, indicating that their actions against C. glabrata were comparable. This study revealed the inhibitory effects of anti-C.a.IgY and anti-C.g.IgY against the adherence of C. albicans and C. glabrata to denture base material. This finding indicates the possibility of a beneficial effect of IgYs for the prevention of denture stomatitis and candidiasis in clinical settings. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  1. [Preferred sites of accumulation of microbial plaque as shown by the color of the exterior surface of complete dentures].

    PubMed

    Merdes, L; Soueidan, A; Le Bars, P; Tabbi-Aneni, N

    2009-03-01

    The observation of the denture plaque for complete dentures caused many clinical works and researches, since 30 years. Most of the studies were interested, by the prosthetic under-surface. New data show that the polished (exterior) surface on the denture palate is colonized more than hard palate. The aim of our study is to locate the favorite zones of the accumulation of the denture plaque on the level of the suction polished faces of the acrylic resin. We proceeded by immersion during 24 hours of 62 used full dentures belongs to 33 patients, with mucous membranes of various clinical aspects in a plaque disclosing solution of erythrosine type. The suction faces were divided into several zones of marking. We record 100% of coloring of the interdental zones on the maxillary and mandibular prosthesis. On maxillary prosthesis: 100% of the former and posterior vestibular zones are colored. The bottom of the palate is colored to 67.74%, a rate equivalent to the zones of fractures. On mandibular prosthesis: retromolar and sublingual zones, are colored to 96.77%. The former hall is colored with a rate of 90.32%. The posterior vestibular zone seems the least colored with a rate of 80.64%. The former area of the hall carved in an aesthetic objective is generally colored as well on the maxillary and mandibular prosthesis. We point out that this zone should not be much carved on the level of the area simulating the attached gum. Patients should be always incited to practice a mechanical hygiene, which takes part largely in the evacuation of the denture plaque on prosthetic surfaces. This revealing plaque use should integrate a clinical attitude of good practice, to motivate a patient with prosthetic hygiene or to detect zones of cracks objectifying a mechanical weakness of a prosthesis to be taken again, as well as the checking of the quality of repair joint during a routine control.

  2. DIY dentures--a case report.

    PubMed

    Jagger, D C; Harrison, A

    1996-03-23

    Minor self adjustments to dentures is a common finding. This case report describes do-it-yourself major adjustments to a removable prosthesis in an attempt to convert it to a fixed prosthesis and the resultant damage to the dental tissues.

  3. Relationship between the use of full dentures and mucosal alterations among elderly Brazilians.

    PubMed

    Freitas, J B; Gomez, R S; De Abreu, M H N G; Ferreira E Ferreira, E

    2008-05-01

    The objective of the present study was to evaluate the prevalence of oral mucosal lesions associated with the use of full dentures (FD) among non-institutionalized individuals of 60 or more years of age in a rural Brazilian population. The sample consisted of 344 individuals aged 60 or more from two rural communities of Brazil. Of this total, 146 were FD users and 198 FD, non-users. Angular cheilitis, denture stomatitis and inflammatory fibrous hyperplasia were statistically associated with prosthesis use. Hygiene and integrity of the prosthesis were related to the presence of oral lesions. While inflammatory fibrous hyperplasia was positively related to FD integrity, denture stomatitis was associated with time of use, hygiene status and integrity of FD. The results indicate the need for oral health care programmes for the elderly and show a relationship between time of use, quality and hygiene of oral prostheses with the presence of mucosal lesions.

  4. Complete denture base assessments using holograms: dimensional alterations after different activation methods

    NASA Astrophysics Data System (ADS)

    Dughir, Ciprian; Popovschi, Ana Maria; Cojocariu, Andreea Codruta; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Sinescu, Cosmin; de Sabata, Aldo; Duma, Virgil-Florin

    2016-03-01

    Holography is a well-developed method with a large range of applications, including dentistry. This study uses holographic methods for the study of total dental prosthesis. The issue is that the transformation of wax denture base in polymethylacrylate causes dimensional alterations and retractions in the final dental constructs. These could cause the failure of the stability of the complete denture in the oral cavity. Thus, the aim of this study is to determine and to compare using holography, total prosthesis obtained using three different manufacturing methods: pressing, injection, and polymerization. Each of the three types of dentures thus produced were recorded over the previously wax complete base holographic plates. The dimensional alterations that appear after using the different activation methods were thus determined. The most significant modification was remarked in the custom press technology, while the smallest variations were detected in the injection alternative.

  5. Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer.

    PubMed

    Koodaryan, Roodabeh; Hafezeqoran, Ali

    2016-12-01

    Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (α=.05). The bond strength values of A and S were significantly higher than those of N ( P <.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG ( P <.001). The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.

  6. Hardness and surface roughness of enamel and base layers of resin denture teeth after long-term repeated chemical disinfection.

    PubMed

    Neppelenbroek, Karin Hermana; Kurokawa, Luciana Ayumi; Procópio, Andréa Lemos Falcão; Pegoraro, Thiago Amadei; Hotta, Juliana; Mello Lima, Jozely Francisca; Urban, Vanessa Migliorini

    2015-01-01

    To evaluate the effect of successive cycles of disinfection in different denture cleansers on the surface roughness and the Vickers hardness of two layers of acrylic resin (base-BL and enamel-EL) of two commercial cross-linked artificial teeth. The occlusal surfaces of 60 acrylic resin denture posterior teeth (Trilux-TLX and SR Orthosit PE-SRO) embedded in autopolymerizing acrylic resin were ground fat with 1200-grit silicon carbide paper. Specimens were stored in distilled water at 37°C and then submitted to the microhardness (VHN) and roughness (μm) tests. Specimens were stored in distilled water at 37°C for 90 days and submitted to 720 disinfection cycles in sodium hypochlorite at 0.5%, 30% vinegar solution or distilled water (control). Afterward, micro-hardness and roughness tests were again performed. Data were analyzed using two-way ANOVA and Tukey's test (α=0.05). Hypochlorite immersion decreased the hardness of BL and EL of SRO teeth, with an average reduction of 10.11% (p<0.008). TLX teeth demonstrated a hardness reduction of 28.96% of both layers for all solutions including water (p<0.0000). The roughness of both teeth was not affected by denture cleansers (p>0.37). Hypochlorite promoted deleterious effects on the hardness of both layers of the artificial teeth tested. Immersion in vinegar and water also resulted in reduction of hardness of TLX teeth. The surface hardness of the different layers of cross-linked artificial teeth can be altered by daily disinfection in denture cleansers commonly indicated for removable dentures.

  7. Effect of phosphate group addition on the properties of denture base resins

    PubMed Central

    Puri, Gaurav; Berzins, David W.; Dhuru, Virendra B.; Raj, Periathamby A.; Rambhia, Sameer K.; Dhir, Gunjan; Dentino, Andrew R.

    2009-01-01

    Statement of problem Acrylic resins are prone to microbial adherence, especially by Candida albicans. Surface-charged resins alter the ionic interaction between the denture resin and Candida hyphae, and these resins are being developed as a means to reduce microbial colonization on the denture surface. Purpose The purpose of this study was to investigate the physical and mechanical properties of phosphate-containing polymethyl methacrylate resins for their suitability as a denture material. Material and methods Using PMMA with cross-linker (Lucitone 199) as a control, 4 experimental groups containing various levels of phosphate with and without cross-linker were generated. The properties examined were impact strength, fracture toughness, wettability (contact angle), and resin bonding ability to denture teeth. Impact strength was tested in the Izod configuration (n=16), and fracture toughness (n=13) was measured using the single-edge notched bend test. Wettability was determined by calculating the contact angle of water on the material surface (n=12), while ISO 1567 was used for bonding ability (n=12). The data were analyzed by 1- and 2-way ANOVA (α=.05). Results A trend of increased hydrophilicity, as indicated by lower contact angle, was observed with increased concentrations of phosphate. With regard to the other properties, no significant differences were found when compared with the control acrylic resin. Conclusions No adverse physical effect due to the addition of a phosphate-containing monomer was found in the acrylic denture resins. Additional mechanical and physical properties, biocompatibility, and clinical efficacy studies are needed to confirm the in vivo anti-Candida activity of these novel resins. PMID:18922259

  8. Long-term efficacy of denture cleansers in preventing Candida spp. biofilm recolonization on liner surface.

    PubMed

    Vieira, Ana Paula Coelho; Senna, Plínio Mendes; Silva, Wander José da; Del Bel Cury, Altair Antoninha

    2010-01-01

    This study evaluated the long-term efficacy of denture cleansers against Candida spp. biofilm recolonization on liner surface. Specimens were fabricated of a poly(methyl methacrylate)-based denture liner and had their surface roughness evaluated at baseline and after cleansing treatments. C. albicans or C. glabrata biofilms were formed on liner surface for 48 h, and then the specimens were randomly assigned to one of cleaning treatments: two alkaline peroxides (soaking for 3 or 15 min), 0.5% sodium hypochlorite (10 min) or distilled water (control; 15 min). After the treatments, the specimens were sonicated to disrupt the biofilm, and residual cells were counted (cell/mL). Long-term effectiveness of the cleaning processes was determined by submitting a set of cleaned specimens to biofilm growth conditions for 48 h followed by estimation of cell counts. The topography of specimens after cleaning treatments was analyzed by SEM. Data were analyzed by ANOVA and Tukey's test (α; = 0.05). Results of cell count estimation showed significant differences in cleanliness among the treatments (p < 0.001), and it could be observed by SEM. However, no significant difference (p > 0.05) was observed among the Candida species regarding the recolonization condition. Alkaline denture cleansers showed similar cleaning performance and both differed from the control (p < 0.001). Sodium hypochlorite was the only treatment that removed biofilm efficiently, since no viable cells were found after its use. In conclusion, alkaline peroxide denture cleansers were not effective in removing Candida spp. biofilm from denture liner surfaces and preventing biofilm recolonization.

  9. Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

    PubMed Central

    Shah, Farhan Khalid; Gebreel, Ashraf; Elshokouki, Ali hamed; Habib, Ahmed Ali

    2012-01-01

    PURPOSE To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis. PMID:22737309

  10. The soft X-ray polychromator for the Solar Maximum Mission

    NASA Technical Reports Server (NTRS)

    Acton, L. W.; Finch, M. L.; Gilbreth, C. W.; Culhane, J. L.; Bentley, R. D.; Bowles, J. A.; Guttridge, P.; Gabriel, A. H.; Firth, J. G.; Hayes, R. W.

    1980-01-01

    The paper considers the soft X-ray polychromator (XRP) operating in the 1.4-22.4 A range of the soft X-ray spectrum which includes many emission lines important for the diagnosis of plasmas in the 1.5-50 million deg temperature range. The flat crystal scanning spectrometer provides for a channel polychromatic mapping of flares and active regions in the resonance lines of O VIII, Ne IX, and Mg XI; in its spectral scanning mode it covers essentially the entire 1.4-22.5 A region.

  11. The soft X-ray polychromator for the Solar Maximum Mission

    NASA Astrophysics Data System (ADS)

    Acton, L. W.; Culhane, J. L.; Gabriel, A. H.; Bentley, R. D.; Bowles, J. A.; Firth, J. G.; Finch, M. L.; Gilbreth, C. W.; Guttridge, P.; Hayes, R. W.; Joki, E. G.; Jones, B. B.; Kent, B. J.; Leibacher, J. W.; Nobles, R. A.; Patrick, T. J.; Phillips, K. J. H.; Rapley, C. G.; Sheather, P. H.; Sherman, J. C.; Stark, J. P.; Springer, L. A.; Turner, R. F.; Wolfson, C. J.

    1980-02-01

    The paper considers the soft X-ray polychromator (XRP) operating in the 1.4-22.4 A range of the soft X-ray spectrum which includes many emission lines important for the diagnosis of plasmas in the 1.5-50 million deg temperature range. The flat crystal scanning spectrometer provides for a channel polychromatic mapping of flares and active regions in the resonance lines of O VIII, Ne IX, and Mg XI; in its spectral scanning mode it covers essentially the entire 1.4-22.5 A region.

  12. 21 CFR 872.3540 - OTC denture cushion or pad.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-counter. (b) Classification. (1) Class I if the device is made of wax-impregnated cotton cloth that the... denture cushion or pad is made of a material other than wax-impregnated cotton cloth or if the intended...

  13. 21 CFR 872.3540 - OTC denture cushion or pad.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...-counter. (b) Classification. (1) Class I if the device is made of wax-impregnated cotton cloth that the... denture cushion or pad is made of a material other than wax-impregnated cotton cloth or if the intended...

  14. 21 CFR 872.3540 - OTC denture cushion or pad.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-counter. (b) Classification. (1) Class I if the device is made of wax-impregnated cotton cloth that the... denture cushion or pad is made of a material other than wax-impregnated cotton cloth or if the intended...

  15. 21 CFR 872.3540 - OTC denture cushion or pad.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...-counter. (b) Classification. (1) Class I if the device is made of wax-impregnated cotton cloth that the... denture cushion or pad is made of a material other than wax-impregnated cotton cloth or if the intended...

  16. 21 CFR 872.3540 - OTC denture cushion or pad.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...-counter. (b) Classification. (1) Class I if the device is made of wax-impregnated cotton cloth that the... denture cushion or pad is made of a material other than wax-impregnated cotton cloth or if the intended...

  17. The Soft X-ray View of Ultra Fast Outflows

    NASA Astrophysics Data System (ADS)

    Reeves, J.; Braito, V.; Nardini, E.; Matzeu, G.; Lobban, A.; Costa, M.; Pounds, K.; Tombesi, F.; Behar, E.

    2017-10-01

    The recent large XMM-Newton programmes on the nearby quasars PDS 456 and PG 1211+143 have revealed prototype ultra fast outflows in the iron K band through highly blue shifted absorption lines. The wind velocities are in excess of 0.1c and are likely to make a significant contribution to the host galaxy feedback. Here we present evidence for the signature of the fast wind in the soft X-ray band from these luminous quasars, focusing on the spectroscopy with the RGS. In PDS 456, the RGS spectra reveal the presence of soft X-ray broad absorption line profiles, which suggests that PDS 456 is an X-ray equivalent to the BAL quasars, with outflow velocities reaching 0.2c. In PG 1211, the soft X-ray RGS spectra show a complex of several highly blue shifted absorption lines over a wide range of ionisation and reveal outflowing components with velocities between 0.06-0.17c. For both quasars, the soft X-ray absorption is highly variable, even on timescales of days and is most prominent when the quasar flux is low. Overall the results imply the presence of a soft X-ray component of the ultra fast outflows, which we attribute to a clumpy or inhomogeneous phase of the disk wind.

  18. Adult plant leaf rust resistance derived from the soft red winter wheat cultivar Caldwell maps to chromosome 3BS

    USDA-ARS?s Scientific Manuscript database

    'Caldwell' is a U.S. soft red winter wheat that has partial, adult plant resistance to the leaf rust pathogen Puccinia triticina. A line of 'Thatcher*2/Caldwell' with adult plant resistance derived from Caldwell was crossed with 'Thatcher' to develop a population of recombinant inbred lines (RILs). ...

  19. Ionized Absorbers in Active Galactic Nuclei and Very Steap Soft X-Ray Quasars

    NASA Technical Reports Server (NTRS)

    Fiore, Fabrizio; White, Nicholas (Technical Monitor)

    2000-01-01

    Steep soft X-ray (0.1-2 keV) quasars share several unusual properties: narrow Balmer lines, strong Fe II emission, large and fast X-ray variability, and a rather steep 2-10 keV spectrum. These intriguing objects have been suggested to be the analogues of Galactic black hole candidates in the high, soft state. We present here results from ASCA observations for two of these quasars: NAB 0205 + 024 and PG 1244 + 026. Both objects show similar variations (factor of approximately 2 in 10 ks), despite a factor of approximately 10 difference in the 0.5-10 keV luminosity (7.3 x 10(exp 43) erg/s for PG 1244 + 026 and 6.4 x 10(exp 44) erg/s for NAB 0205 + 024, assuming isotropic emission, H(sub 0) = 50.0 and q(sub 0) = 0.0). The X-ray continuum of the two quasars flattens by 0.5-1 going from the 0.1-2 keV band towards higher energies, strengthening recent results on another half-dozen steep soft X-ray active galactic nuclei. PG 1244 + 026 shows a significant feature in the '1-keV' region, which can be described either as a broad emission line centered at 0.95 keV (quasar frame) or as edge or line absorption at 1.17 (1.22) keV. The line emission could be a result of reflection from a highly ionized accretion disc, in line with the view that steep soft X-ray quasars are emitting close to the Eddington luminosity. Photoelectric edge absorption or resonant line absorption could be produced by gas outflowing at a large velocity (0.3-0.6 c).

  20. American College of Prosthodontists

    MedlinePlus

    ... Changing Your Diet D Dental Implants Dentures E Enamel Shaping F Fillings Fluoride Full Mouth Reconstruction I ... Relined Dentures S Sealants Splints ... Find the right treatment Condition -- Select Symptom -- Bleeding in Mouth Broken or Chipped Tooth Cavities or Tooth Decay Cleft Lip/Palate Congenital ...

  1. Overdenture restoration in a growing patient with hypohidrotic ectodermal dysplasia: a clinical report.

    PubMed

    Pae, Ahran; Kim, Kyu; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2011-03-01

    Ectodermal dysplasia is a hereditary disorder of ectodermal origin. A 12-year-old boy was referred for management of the oral manifestations of his ectodermal dysplasia. An overdenture retained by natural teeth for the maxilla and a double-crown-retained denture for the mandible were made. Double-crown-retained dentures may be modified into complete dentures if the abutment teeth are lost. The patient was instructed to maintain oral hygiene and return periodically for follow-up visits. This report describes a potential routine approach to restoring the appearance, function, and psyche of a growing boy with ectodermal dysplasia.

  2. Kenny-Caffey Syndrome: oral findings and 4-year follow-up of overlay denture therapy.

    PubMed

    Demir, Tahsin; Kecik, Defne; Cehreli, Zafer C

    2007-01-01

    Kenny-Caffey Syndrome (KCS) is an extremely rare osteosclerotic bone dysplasia associated with hypocalcemia and ocular abnormalities. Although the condition is well reported in the medical literature, dental manifestations have not been discussed in great detail. The purpose of this report is to present specific oral features and prosthetic management in a KCS patient. Overlay dentures were utilized in the management of low vertical dimension of occlusion, congenital absence of several permanent teeth, and problems associated with function and esthetics. Results of the 4-year follow-up overlay denture therapy are presented.

  3. Biometric Denture Space- Concept of Neutral Zone Revisited Using A Hydrocolloid Impression Material

    PubMed Central

    Umamaheswaran, Aruna; Nayar, Sanjna

    2015-01-01

    Though the concept of neutral zone in making complete denture and its significance are well known, the material of choice has always been experimented to achieve better results. Recording of neutral zone using irreversible hydrocolloid (Alginate) as a material of choice would make the way of recording the neutral zone easier, as well as comfortable for the patient, when compared with other materials used for the purpose. This article describes the method of recording the biometric denture space (neutral zone) using hydrocolloid impression material which is most commonly used in everyday dental practice. PMID:26673250

  4. Immunoexpression of vascular endothelial growth factor in gingival mucosa with papilloma and condyloma acuminata.

    PubMed

    Scrieciu, Monica; MercuŢ, Veronica; Andrei, Oana Cella; Predescu, Anca Mihaela; Niculescu, Mihaela; Pisoschi, Cătălina Gabriela; BaniŢă, Ileana Monica

    2015-01-01

    The histological changes of the oral mucosa in contact with a metal alloy dentures is one of the current issues widely debated in the literature. To highlight the expression of vascular endothelial growth factor (VEGF) in human paraprosthetic gingival mucosa exposed to nickel and copper compounds using the immunohistochemical technique. The selected participants were wearers of fixed dentures made of nickel-based alloys and copper-based alloys. The gingival mucosa fragments were prelevated through excision after removing fixed denture and extraction one of its affected teeth. The gingival mucosa fragments were processed through the histological technique of paraffin inclusion. The paraffin-embedded tissue sections were usually stained with Hematoxylin-Eosin and processed by immunohistochemical technique with VEGF antibody. The gingival mucosa fragments from nickel-based alloys dentures wearers were diagnosed with papilloma and, also, gingival mucosa samples prelevated from copper-based alloys dentures wearers were diagnosed with condyloma acuminata. Immunohistochemical reaction for VEGF was different in the gingival mucosa fragments with papilloma compared with condyloma acuminata samples. In papillomatosis gingival mucosa fragments, VEGF was implicated in principal in vasodilatation and inflammation process, and secondary in angiogenesis. In gingival mucosa fragments with condyloma acuminata, the principal role of VEGF was in angiogenesis and secondary in inflammation.

  5. Verification of finite element analysis of fixed partial denture with in vitro electronic strain measurement.

    PubMed

    Wang, Gaoqi; Zhang, Song; Bian, Cuirong; Kong, Hui

    2016-01-01

    The purpose of the study was to verify the finite element analysis model of three-unite fixed partial denture with in vitro electronic strain analysis and analyze clinical situation with the verified model. First, strain gauges were attached to the critical areas of a three-unit fixed partial denture. Strain values were measured under 300 N load perpendicular to the occlusal plane. Secondly, a three-dimensional finite element model in accordance with the electronic strain analysis experiment was constructed from the scanning data. And the strain values obtained by finite element analysis and in vitro measurements were compared. Finally, the clinical destruction of the fixed partial denture was evaluated with the verified finite element analysis model. There was a mutual agreement and consistency between the finite element analysis results and experimental data. The finite element analysis revealed that failure will occur in the veneer layer on buccal surface of the connector under occlusal force of 570 N. The results indicate that the electronic strain analysis is an appropriate and cost saving method to verify the finite element model. The veneer layer on buccal surface of the connector is the weakest area in the fixed partial denture. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. Present status of titanium removable dentures--a review of the literature.

    PubMed

    Ohkubo, C; Hanatani, S; Hosoi, T

    2008-09-01

    Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.

  7. Cytotoxicity of four denture adhesives on human gingival fibroblast cells.

    PubMed

    Lee, Yoon; Ahn, Jin-Soo; Yi, Young-Ah; Chung, Shin-Hye; Yoo, Yeon-Jee; Ju, Sung-Won; Hwang, Ji-Yun; Seo, Deog-Gyu

    2015-02-01

    The purpose of this study was to compare the cytotoxicity of four denture adhesives on human gingival fibroblast cells. Immortalized human gingival fibroblasts were cultured with one of four different denture adhesives, Polident, Protefix, Staydent or Denfix-A, which was placed in insert dishes (10% w/v concentration) for 48 h. The MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay and flow cytometric apoptosis assay were used to evaluate cell viability and apoptosis rates. The fibroblasts were also examined under a scanning electron microscope. The MTT assay showed that all denture adhesives resulted in a significantly lower cell viability compared to the control cells propagated in normal culture medium (p < 0.05), with Staydent demonstrating the lowest cell viability. According to the flow cytometric apoptosis assay, Staydent and Protefix showed significantly higher apoptosis rates than the control group (p < 0.05), whereas Polident and Denfix-A did not demonstrate any significant differences (p > 0.05). Staydent showed the highest apoptosis rate. Scanning electron microscopy showed that the cells of the Staydent group underwent cytoplasmic membrane shrinkage, with cell free areas containing residual fragments of the membrane of dead cells. The four denture adhesives evaluated in this study imparted cytotoxic effects on human gingival fibroblast cells. Staydent showed the highest toxicity.

  8. Space Telescope and Optical Reverberation Mapping Project. VII. Understanding the Ultraviolet Anomaly in NGC 5548 with X-Ray Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathur, S.; Gupta, A.; Page, K.

    During the Space Telescope and Optical Reverberation Mapping Project observations of NGC 5548, the continuum and emission-line variability became decorrelated during the second half of the six-month-long observing campaign. Here we present Swift and Chandra X-ray spectra of NGC 5548 obtained as part of the campaign. The Swift spectra show that excess flux (relative to a power-law continuum) in the soft X-ray band appears before the start of the anomalous emission-line behavior, peaks during the period of the anomaly, and then declines. This is a model-independent result suggesting that the soft excess is related to the anomaly. We divide themore » Swift data into on- and off-anomaly spectra to characterize the soft excess via spectral fitting. The cause of the spectral differences is likely due to a change in the intrinsic spectrum rather than to variable obscuration or partial covering. The Chandra spectra have lower signal-to-noise ratios, but are consistent with the Swift data. Our preferred model of the soft excess is emission from an optically thick, warm Comptonizing corona, the effective optical depth of which increases during the anomaly. In conclusion, this model simultaneously explains all three observations: the UV emission-line flux decrease, the soft-excess increase, and the emission-line anomaly.« less

  9. Space Telescope and Optical Reverberation Mapping Project. VII. Understanding the Ultraviolet Anomaly in NGC 5548 with X-Ray Spectroscopy

    DOE PAGES

    Mathur, S.; Gupta, A.; Page, K.; ...

    2017-08-31

    During the Space Telescope and Optical Reverberation Mapping Project observations of NGC 5548, the continuum and emission-line variability became decorrelated during the second half of the six-month-long observing campaign. Here we present Swift and Chandra X-ray spectra of NGC 5548 obtained as part of the campaign. The Swift spectra show that excess flux (relative to a power-law continuum) in the soft X-ray band appears before the start of the anomalous emission-line behavior, peaks during the period of the anomaly, and then declines. This is a model-independent result suggesting that the soft excess is related to the anomaly. We divide themore » Swift data into on- and off-anomaly spectra to characterize the soft excess via spectral fitting. The cause of the spectral differences is likely due to a change in the intrinsic spectrum rather than to variable obscuration or partial covering. The Chandra spectra have lower signal-to-noise ratios, but are consistent with the Swift data. Our preferred model of the soft excess is emission from an optically thick, warm Comptonizing corona, the effective optical depth of which increases during the anomaly. In conclusion, this model simultaneously explains all three observations: the UV emission-line flux decrease, the soft-excess increase, and the emission-line anomaly.« less

  10. Space Telescope and Optical Reverberation Mapping Project. VII. Understanding the Ultraviolet Anomaly in NGC 5548 with X-Ray Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathur, S.; Pogge, R. W.; Adams, S. M.

    During the Space Telescope and Optical Reverberation Mapping Project observations of NGC 5548, the continuum and emission-line variability became decorrelated during the second half of the six-month-long observing campaign. Here we present Swift and Chandra X-ray spectra of NGC 5548 obtained as part of the campaign. The Swift spectra show that excess flux (relative to a power-law continuum) in the soft X-ray band appears before the start of the anomalous emission-line behavior, peaks during the period of the anomaly, and then declines. This is a model-independent result suggesting that the soft excess is related to the anomaly. We divide themore » Swift data into on- and off-anomaly spectra to characterize the soft excess via spectral fitting. The cause of the spectral differences is likely due to a change in the intrinsic spectrum rather than to variable obscuration or partial covering. The Chandra spectra have lower signal-to-noise ratios, but are consistent with the Swift data. Our preferred model of the soft excess is emission from an optically thick, warm Comptonizing corona, the effective optical depth of which increases during the anomaly. This model simultaneously explains all three observations: the UV emission-line flux decrease, the soft-excess increase, and the emission-line anomaly.« less

  11. Treatment of Biofouling in Internal Seawater Systems - Phase 2

    DTIC Science & Technology

    2007-11-01

    Denture Cleansing Tablets. Issue Date: Feb 2006. Reckitt Benckiser 12 In the first instance, in July 2006, mussels were transferred directly to an...Denture Cleansing Tablets (Reckit Benckiser , West Ryde) Chemical composition11: Potassium peroxymonosulfate 10-30% Sodium carbonate ᝺% Citric

  12. Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study

    PubMed Central

    Jujare, Ravikanth Haridas; Varghese, Rana Kalappattil; Singh, Vishwa Deepak; Gaurav, Amit

    2016-01-01

    Introduction Dental professionals are exposed to a wide variety of microorganisms which calls for use of effective infection control procedures in the dental office and laboratories that can prevent cross-contamination that could extend to dentists, dental office staff, dental technicians as well as patients. This concern has led to a renewed interest in denture sterilization and disinfection. Heat polymerized dentures exhibit dimensional change during disinfection procedure. Aim The purpose of this study was to determine the influence of different types of widely used laboratory disinfecting agents on the dimensional stability of heat-cured denture acrylic resins and to compare the dimensional stability of three commercially available heat-cured denture acrylic resins in India. Materials and Methods Twelve specimens of uniform dimension each of three different brands namely Stellon, Trevalon and Acralyn-H were prepared using circular metal disc. Chemical disinfectants namely 2% alkaline glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite and water as control group were used. Diameter of each specimen was measured before immersion and after immersion with time interval of 1 hour and 12 hours. The data was evaluated statistically using one way analysis of variance. Results All the specimens in three disinfectants and in water exhibited very small amount of linear expansion. Among three disinfectants, specimens in 2% alkaline glutaraldehyde exhibited least(0.005mm) and water showed highest (0.009mm) amount of dimensional change. Among resins, Trevalon showed least (0.067mm) and Acralyn-H exhibited highest (0.110mm) amount of dimensional change. Conclusion Although, all the specimens of three different brands of heat-cured denture acrylic resins exhibited increase in linear dimensional change in all the disinfectants and water, they were found to be statistically insignificant. PMID:27134996

  13. Comparability of clinical wear measurements by optical 3D laser scanning in two different centers.

    PubMed

    Stober, Thomas; Heuschmid, Navina; Zellweger, Gaby; Rousson, Valentin; Rues, Stefan; Heintze, Siegward D

    2014-05-01

    The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers. Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model. Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Influence of reinforcement on strains within maxillary implant overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    2015-01-01

    The purpose of this study was to examine the influence of reinforcement of an embedded cast on the strains within maxillary implant overdentures. A maxillary edentulous model with implants placed bilaterally in the canine positions, dome-shaped copings, and experimental overdentures was fabricated. Rosette-type strain gauges were attached in the canine positions and at three points along the midline of the polished surface of the denture and connected to the sensor interface controlled by a personal computer. Experimental dentures with five different reinforcements were tested: without reinforcement; with a cast cobalt-chrome reinforcement over the residual ridge and the tops of the copings; with the same reinforcement from first molar to first molar, over the residual ridge and the tops of the copings; with the same reinforcement over the residual ridge and the sides of the copings; and with the same reinforcement from first molar to first molar, over the residual ridge and the sides of the copings. A vertical occlusal load of 49 N was applied to the first premolar and then to the first molar, and the strains were measured and compared by analysis of variance. In both loading situations, significantly less strain was recorded in dentures with reinforcement than in those without reinforcement. When the first premolar was loaded on dentures with and without palatal reinforcement at the first premolars, the strains on the denture with reinforcement over the tops of the copings were significantly lower than on the denture with reinforcement over the sides of the copings at the canine position. Cast reinforcement over the residual ridge and the top of copings embedded in an acrylic base reduced the strain from occlusal stress on maxillary implant overdentures.

  15. The Effect of Different Chemical Surface Treatments of Denture Teeth on Shear Bond Strength: A Comparative Study

    PubMed Central

    Palekar, Umesh; Awinashe, Vaibav; Mishra, Sunil Kumar; Kawadkar, Abhishek; Rahangdale, Tripti

    2014-01-01

    Background: The development of better cross linked acrylic resin teeth has solved the problems related to wearing and discoloration of acrylic teeth. The same cross linking at ridge lap region acts as a double edge sword as it weakens the bond between denture base and tooth. Aim of Study: The purpose of study was to evaluate the effect of surface treatment on the bond strength of resin teeth to denture base resin using monomethyl methacrylate monomer and dichloromethane with no surface treatment acting as control. Settings and Design:Denture base cylinder samples in wax (n=180) were made with maxillary central incisor attached at 450 (JIST 6506). These samples were randomly and equally divided into three groups of 60 each. These specimens were then flasked, dewaxed as per the standard protocol. Materials and Methods: Before acrylization, ridge lap area was treated as follows: Group A- no surface treatment act as control, Group B treated with monomethyl methacrylate monomer, Group C treated with dichloromethane. Digitally controlled acryliser was used for acrylization as per manufacturer’s instructions and shear bond strength was tested on Universal Testing Machine (Servo Hydraulic, 50kN High Strain, BISS Research). Statistical Analysis used: Result was statistically analyzed with One-way analysis of variance (ANOVA) and Post-hoc ANOVA Tukey’s HSD test at 5% level of significance. Results: The application of dichloromethane showed increased bond strength between cross linked acrylic resin teeth and heat cure denture base resin followed by monomethyl methacrylate monomer and control group. Conclusion: The application of dichloromethane on the ridge lap surface of the resin teeth before packing of the dough into the mold significantly increased the bond strength between cross linked acrylic resin teeth and heat cure denture base resin. PMID:25121057

  16. The impact of oral rehabilitation on oral health-related quality of life in patients receiving radiotherapy for the treatment of head and neck cancer.

    PubMed

    Schweyen, Ramona; Kuhnt, Thomas; Wienke, Andreas; Eckert, Alexander; Hey, Jeremias

    2017-05-01

    To analyze the influence of dental treatment on oral health-related quality of life (OHRQoL) in head and neck cancer patients. This study included the data of 116 patients who underwent radiotherapy (RT) because of head and neck cancer. For each patient, the variables age, sex, tumor site, irradiation technique, dose on the spared parotid gland, concomitant chemotherapy, and denture status were documented. OHRQoL was determined using the OHIP-G14 questionnaire. Patients were divided into subgroups according to denture status: none or fixed partial dentures (none/FPD), removable partial dentures (RPD), and full dentures (CD). OHIP summary scores were determined and tested for clinical relevant differences with respect to the different variables. The association between OHRQol and the variables was assessed using linear regression. No clinically relevant influence on OHRQoL was found for gender, irradiation technique, and chemotherapy. Patients with tumors located in the oral cavity had a significantly higher OHIP score than patients with other tumor sites (p < 0.001). None/FPD and RPD patients had higher values than those found in a normal population, but did not differ significantly from each other (p = 0.387). In contrast to tumor site, teeth and type of denture seem to have a limited effect on OHRQoL in head and neck cancer patients. Prosthetic treatment in head and neck cancer patients do not lead to the same improvement in OHRQoL as found in the normal population. This might be taken into account especially if extensive dental treatment is intended.

  17. Screw joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions.

    PubMed

    Farina, Ana Paula; Spazzin, Aloísio Oro; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz

    2014-06-01

    Screws can loosen through mechanisms that have not been clearly established. The purpose of this study was to evaluate the influence of the tightening technique (the application of torque and retorque on the joint stability of titanium and gold prosthetic screws) in implant-supported dentures under different fit levels after 1 year of simulated masticatory function by means of mechanical cycling. Ten mandibular implant-supported dentures were fabricated, and 20 cast models were prepared by using the dentures to create 2 fit levels: passive fit and created misfit. The tightening protocol was evaluated according to 4 distinct profiles: without retorque plus titanium screws, without retorque plus gold screws, retorque plus titanium screws, and retorque plus gold screws. In the retorque application, the screws were tightened to 10 Ncm and retightened to 10 Ncm after 10 minutes. The screw joint stability after 1 year of simulated clinical function was measured with a digital torque meter. Data were analyzed statistically by 2-way ANOVA and Tukey honestly significant difference (HSD) post hoc tests (α=.05). The factors of fit level and tightening technique as well as the interaction between the factors, were statistically significant. The misfit decreases the loosening torque. The retorque application increased joint stability independent of fit level or screw material, which suggests that this procedure should be performed routinely during the tightening of these devices. All tightening techniques revealed reduced loosening torque values that were significantly lower in misfit dentures than in passive fit dentures. However, the retorque application significantly increased the loosening torque when titanium and gold screws were used. Therefore, this procedure should be performed routinely during screw tightening. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Effect of storage in artificial saliva and thermal cycling on Knoop hardness of resin denture teeth.

    PubMed

    Assunção, Wirley Gonçalves; Gomes, Erica Alves; Barão, Valentim Adelino Ricardo; Barbosa, Débora Barros; Delben, Juliana Aparecida; Tabata, Lucas Fernando

    2010-07-01

    This study aimed to evaluate the effect of different storage periods in artificial saliva and thermal cycling on Knoop hardness of 8 commercial brands of resin denture teeth. Eigth different brands of resin denture teeth were evaluated (Artplus group, Biolux group, Biotone IPN group, Myerson group, SR Orthosit group, Trilux group, Trubyte Biotone group, and Vipi Dent Plus group). Twenty-four teeth of each brand had their occlusal surfaces ground flat and were embedded in autopolymerized acrylic resin. After polishing, the teeth were submitted to different conditions: (1) immersion in distilled water at 37+/-2 degrees C for 48+/-2h (control); (2) storage in artificial saliva at 37+/-2 degrees C for 15, 30 and 60 days, and (3) thermal cycling between 5 and 55 degrees C with 30-s dwell times for 5000 cycles. Knoop hardness test was performed after each condition. Data were analyzed with two-way ANOVA and Tukey's test (alpha=.05). In general, SR Orthosit group presented the highest statistically significant Knoop hardness value while Myerson group exhibited the smallest statistically significant mean (P<.05) in the control period, after thermal cycling, and after all storage periods. The Knoop hardness means obtained before thermal cycling procedure (20.34+/-4.45 KHN) were statistically higher than those reached after thermal cycling (19.77+/-4.13 KHN). All brands of resin denture teeth were significantly softened after storage period in artificial saliva. Storage in saliva and thermal cycling significantly reduced the Knoop hardness of the resin denture teeth. SR Orthosit denture teeth showed the highest Knoop hardness values regardless the condition tested. Copyright 2010 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  19. Assessment of the use of xerogenic medications for chronic medical and dental conditions among adult day health participants.

    PubMed

    Lam, Annie; Kiyak, Asuman; Gossett, Allison M; McCormick, Lawrence

    2009-10-01

    To describe the health conditions, dental problems, and use of xerogenic medications among dental patients in adult day health (ADH) centers. Cross-sectional descriptive study. ADH centers in King County, Washington. ADH clients who were patients of a mobile dental service. Pharmacist-conducted chart reviews and in-person medication reviews with patients. Demographic description, mean numbers of medical and dental problems, medications, xerogenic medications used per subject, and identification of xerogenic medications by therapeutic class. At five sites, 97 patients were interviewed (average age 73.8 +/- 11.8 years, 61% female); ethnicities included: Asian-American (37.1%), Caucasian (30.9%), Russian (29%), and African-American (3%). Mean numbers of chronic health problems, medications, and xerogenic medications per patient were 5.2 +/- 2.7, 10.9 +/- 4.4, and 3.3 +/- 1.8, respectively. Antidepressants were the most commonly used xerogenic medication, followed by antipsychotics, antiemetics, analgesics, and antihistamines. Among 74 patients who received dental treatment, 33 (44.6%) wore dentures. Among 58 patients with teeth, a mean number of 2.8 dental problems per patient was identified. Dental caries (51.7%) was the most prevalent problem, followed by periodontitis (29.3%), soft tissue lesions (10.3%), gingivitis (5.2%), and candidiasis (3.4%). Multiple systemic diseases, use of multiple xerogenic medications, and poor oral health were prevalent among the ADH clients in this study. However, self-reports of dry mouth were unrelated to number of xerogenic medications or oral conditions. Further research is needed to determine the association between self-reported dry mouth, chronic health conditions, use of xerogenic medications, tooth loss, and/or denture use.

  20. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible.

    PubMed

    Hayama, Hironari; Fueki, Kenji; Wadachi, Juro; Wakabayashi, Noriyuki

    2018-03-01

    It remains unclear whether digital impressions obtained using an intraoral scanner are sufficiently accurate for use in fabrication of removable partial dentures. We therefore compared the trueness and precision between conventional and digital impressions in the partially edentulous mandible. Mandibular Kennedy Class I and III models with soft silicone simulated-mucosa placed on the residual edentulous ridge were used. The reference models were converted to standard triangulated language (STL) file format using an extraoral scanner. Digital impressions were obtained using an intraoral scanner with a large or small scanning head, and converted to STL files. For conventional impressions, pressure impressions of the reference models were made and working casts fabricated using modified dental stone; these were converted to STL file format using an extraoral scanner. Conversion to STL file format was performed 5 times for each method. Trueness and precision were evaluated by deviation analysis using three-dimensional image processing software. Digital impressions had superior trueness (54-108μm), but inferior precision (100-121μm) compared to conventional impressions (trueness 122-157μm, precision 52-119μm). The larger intraoral scanning head showed better trueness and precision than the smaller head, and on average required fewer scanned images of digital impressions than the smaller head (p<0.05). On the color map, the deviation distribution tended to differ between the conventional and digital impressions. Digital impressions are partially comparable to conventional impressions in terms of accuracy; the use of a larger scanning head may improve the accuracy for removable partial denture fabrication. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Top