Science.gov

Sample records for des ions multicharges

  1. Slow collisions of multicharged ions with metal surfaces

    SciTech Connect

    Meyer, F.W.

    1993-12-31

    Some recent experimental results in the area of multicharged ion-surface interactions are summarized. Discussed are measurements of projectile K-Auger electron emission during interactions of hydrogen-like multicharged ions with clean and cesiated metal surfaces, measurements of total electron yields for various multicharged ions incident on metal targets, and measurements of projectile angular scattering during grazing metal surface collisions. The various experimental results are presented to illustrate progress in the understanding of multicharged ion-surface interactions in the area of above- vs sub-surface neutralization and relaxation processes, as well as to identify certain aspects of such interactions where the picture is as yet still incomplete.

  2. Conductometric investigations of multicharged ion track structure in various polymers

    NASA Astrophysics Data System (ADS)

    Apel, P. Yu.

    The radial structure of etchable tracks of multicharged ions in polyethylene terephtalate, polycarbonate, polyarylate, and polypropylene is investigated using conductometric method. The doses of gel formation under irradiation of these polymers by accelerated xenon ions with approximately 1 MeV/nucleon energy are estimated. It is found that the track of highly ionizing particles in a polymer consists of a core where intensive destruction occurs and a halo where, as a rule, the crosslinking of macromolecules predominates. Recombination of the interior radicals provides the crosslinking formation. The radius of the crosslinking region depends on the relation between the hydrogen atom diffusion speed and the rate of their chemical interaction with macromolecules.

  3. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma

    NASA Astrophysics Data System (ADS)

    Kato, Yushi; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu

    2016-02-01

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  4. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma.

    PubMed

    Kato, Yushi; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu

    2016-02-01

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred. PMID:26931928

  5. Beam Extraction from Laser Driven Multi-Charged Ion Source

    SciTech Connect

    Anderson, O A; Logan, B G

    2001-03-19

    A newly proposed type of multicharged ion source offers the possibility of an economically advantageous high-charge-state fusion driver. Multiphoton absorption in an intense uniform laser focus can give multiple charge states of high purity, simplifying or eliminating the need for charge-state separation downstream. Very large currents (hundreds of amperes) can be extracted from this type of source. Several arrangements are possible. For example, the laser plasma could be tailored for storage in a magnetic bucket, with beam extracted from the bucket. A different approach, described in this report, is direct beam extraction from the expanding laser plasma. They discuss extraction and focusing for the particular case of a 4.1-MV beam of Xe{sup 16+} ions. The maximum duration of the beam pulse is limited by the total charge in the plasma, while the practical pulse length is determined by the range of plasma radii over which good beam optics can be achieved. The extraction electrode contains a solenoid for beam focusing. The design studies were carried out first with an envelope code and then with a self-consistent particle code. Results from the initial model showed that hundreds of amperes could be extracted, but that most of this current missed the solenoid entrance or was intercepted by the wall and that only a few amperes were able to pass through. They conclude with an improved design which increases the surviving beam to more than 70 amperes.

  6. QED Approach to Modeling Spectra of the Multicharged Ions in a Plasma: Oscillator and Electron-ion Collision Strengths

    SciTech Connect

    Glushkov, A. V.; Khetselius, O. Yu.; Loboda, A. V.; Ignatenko, A.; Svinarenko, A.; Korchevsky, D.; Lovett, L.

    2008-10-22

    The uniform energy approach, formally based on the QED theory with using gauge invariant scheme of generation of the optimal one-electron representation, is used for the description of spectra of the multicharged ions in a laser plasma, calculation of electron-ion collision strengths, cross-sections in Ne-like and Ar-like ions.

  7. Producing multicharged fullerene ion beam extracted from the second stage of tandem-type ECRIS

    NASA Astrophysics Data System (ADS)

    Nagaya, Tomoki; Nishiokada, Takuya; Hagino, Shogo; Uchida, Takashi; Muramatsu, Masayuki; Otsuka, Takuro; Sato, Fuminobu; Kitagawa, Atsushi; Kato, Yushi; Yoshida, Yoshikazu

    2016-02-01

    We have been constructing the tandem-type electron cyclotron resonance ion source (ECRIS). Two ion sources of the tandem-type ECRIS are possible to generate plasma individually, and they also confined individual ion species by each different plasma parameter. Hence, it is considered to be suitable for new materials production. As the first step, we try to produce and extract multicharged C60 ions by supplying pure C60 vapor in the second stage plasma because our main target is producing the endohedral fullerenes. We developed a new evaporator to supply fullerene vapor, and we succeeded in observation about multicharged C60 ion beam in tandem-type ECRIS for the first time.

  8. Development of a 1+/N+ setup for the production of multicharged radioactive alkali ions in SPIRAL.

    PubMed

    Eléon, C; Gaubert, G; Jardin, P; Saint-Laurent, M-G; Alcantara, J; Alvès Condé, R; Barué, C; Boilley, D; Cornell, J C; Delahaye, P; Dubois, M; Jacquot, B; Leherissier, P; Leroy, R; Lhersonneau, G; Marie-Jeanne, M; Maunoury, L; Pacquet, J-Y; Pellemoine, F; Pierret, C; Thomas, J C; Villari, A C C

    2008-02-01

    In the framework of the production of radioactive ion beams by the isotope separator online method, a new system has been developed at GANIL/SPIRAL I to produce multicharged alkali ions. The principle, referred to as the "direct 1+/N+ method," consists of a surface ionization source associated with a multicharged electron-cyclotron-resonance ion source without an intermediate mass separator. This new system has been tested online using a (48)Ca primary beam at 60.3 A MeV. The experimental evidence of the direct 1+/N+ process has been obtained for a potential difference between the two sources of 11 V and with a 1+/N+ charge breeding efficiency of 0.04% for (47)K(5+). This value is significantly lower than the value of 6% obtained for stable K ions with the standard 1+/N+ method. A possible explanation is given in the text.

  9. Development of a 1+/N+ setup for the production of multicharged radioactive alkali ions in SPIRALa)

    NASA Astrophysics Data System (ADS)

    Eléon, C.; Gaubert, G.; Jardin, P.; Saint-Laurent, M.-G.; Alcantara, J.; Alvès Condé, R.; Barué, C.; Boilley, D.; Cornell, J. C.; Delahaye, P.; Dubois, M.; Jacquot, B.; Leherissier, P.; Leroy, R.; Lhersonneau, G.; Marie-Jeanne, M.; Maunoury, L.; Pacquet, J.-Y.; Pellemoine, F.; Pierret, C.; Thomas, J. C.; Villari, A. C. C.

    2008-02-01

    In the framework of the production of radioactive ion beams by the isotope separator online method, a new system has been developed at GANIL/SPIRAL I to produce multicharged alkali ions. The principle, referred to as the "direct 1+/N+ method," consists of a surface ionization source associated with a multicharged electron-cyclotron-resonance ion source without an intermediate mass separator. This new system has been tested online using a Ca48 primary beam at 60.3AMeV. The experimental evidence of the direct 1+/N+ process has been obtained for a potential difference between the two sources of 11V and with a 1+/N+ charge breeding efficiency of 0.04% for K5+47. This value is significantly lower than the value of 6% obtained for stable K ions with the standard 1+/N+ method. A possible explanation is given in the text.

  10. Electron energy distribution function by using probe method in electron cyclotron resonance multicharged ion source

    SciTech Connect

    Kumakura, Sho Kurisu, Yosuke; Kimura, Daiju; Yano, Keisuke; Imai, Youta; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki

    2014-02-15

    We are constructing a tandem type electron cyclotron resonance (ECR) ion source (ECRIS). High-energy electrons in ECRIS plasma affect electron energy distribution and generate multicharged ion. In this study, we measure electron energy distribution function (EEDF) of low energy region (≦100 eV) in ECRIS plasma at extremely low pressures (10{sup −3}–10{sup −5} Pa) by using cylindrical Langmuir probe. From the result, it is found that the EEDF correlates with the electron density and the temperature from the conventional probe analysis. In addition, we confirm that the tail of EEDF spreads to high energy region as the pressure rises and that there are electrons with high energy in ECR multicharged ion source plasma. The effective temperature estimated from the experimentally obtained EEDF is larger than the electron temperature obtained from the conventional method.

  11. Electron energy distribution function by using probe method in electron cyclotron resonance multicharged ion source.

    PubMed

    Kumakura, Sho; Kurisu, Yosuke; Kimura, Daiju; Yano, Keisuke; Imai, Youta; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki

    2014-02-01

    We are constructing a tandem type electron cyclotron resonance (ECR) ion source (ECRIS). High-energy electrons in ECRIS plasma affect electron energy distribution and generate multicharged ion. In this study, we measure electron energy distribution function (EEDF) of low energy region (≦100 eV) in ECRIS plasma at extremely low pressures (10(-3)-10(-5) Pa) by using cylindrical Langmuir probe. From the result, it is found that the EEDF correlates with the electron density and the temperature from the conventional probe analysis. In addition, we confirm that the tail of EEDF spreads to high energy region as the pressure rises and that there are electrons with high energy in ECR multicharged ion source plasma. The effective temperature estimated from the experimentally obtained EEDF is larger than the electron temperature obtained from the conventional method.

  12. Multiaperture ion beam extraction from gas-dynamic electron cyclotron resonance source of multicharged ions.

    PubMed

    Sidorov, A; Dorf, M; Zorin, V; Bokhanov, A; Izotov, I; Razin, S; Skalyga, V; Rossbach, J; Spädtke, P; Balabaev, A

    2008-02-01

    Electron cyclotron resonance ion source with quasi-gas-dynamic regime of plasma confinement (ReGIS), constructed at the Institute of Applied Physics, Russia, provides opportunities for extracting intense and high-brightness multicharged ion beams. Despite the short plasma lifetime in a magnetic trap of a ReGIS, the degree of multiple ionization may be significantly enhanced by the increase in power and frequency of the applied microwave radiation. The present work is focused on studying the intense beam quality of this source by the pepper-pot method. A single beamlet emittance measured by the pepper-pot method was found to be approximately 70 pi mm mrad, and the total extracted beam current obtained at 14 kV extraction voltage was approximately 25 mA. The results of the numerical simulations of ion beam extraction are found to be in good agreement with experimental data.

  13. Multiaperture ion beam extraction from gas-dynamic electron cyclotron resonance source of multicharged ions

    SciTech Connect

    Sidorov, A.; Dorf, M.; Zorin, V.; Bokhanov, A.; Izotov, I.; Razin, S.; Skalyga, V.; Rossbach, J.; Spaedtke, P.; Balabaev, A.

    2008-02-15

    Electron cyclotron resonance ion source with quasi-gas-dynamic regime of plasma confinement (ReGIS), constructed at the Institute of Applied Physics, Russia, provides opportunities for extracting intense and high-brightness multicharged ion beams. Despite the short plasma lifetime in a magnetic trap of a ReGIS, the degree of multiple ionization may be significantly enhanced by the increase in power and frequency of the applied microwave radiation. The present work is focused on studying the intense beam quality of this source by the pepper-pot method. A single beamlet emittance measured by the pepper-pot method was found to be {approx}70 {pi} mm mrad, and the total extracted beam current obtained at 14 kV extraction voltage was {approx}25 mA. The results of the numerical simulations of ion beam extraction are found to be in good agreement with experimental data.

  14. Production of multicharged metal ion beams on the first stage of tandem-type ECRIS

    NASA Astrophysics Data System (ADS)

    Hagino, Shogo; Nagaya, Tomoki; Nishiokada, Takuya; Otsuka, Takuro; Muramatsu, Masayuki; Kitagawa, Atsushi; Sato, Fuminobu; Kato, Yushi

    2016-02-01

    Multicharged metal ion beams are required to be applied in a wide range of fields. We aim at synthesizing iron-endohedral fullerene by transporting iron ion beams from the first stage into the fullerene plasma in the second stage of the tandem-type electron cyclotron resonance ion source (ECRIS). We developed new evaporators by using a direct ohmic heating method and a radiation heating method from solid state pure metal materials. We investigate their properties in the test chamber and produce iron ions on the first stage of the tandem-type ECRIS. As a result, we were successful in extracting Fe+ ion beams from the first stage and introducing Fe+ ion beams to the second stage. We will try synthesizing iron-endohedral fullerene on the tandem-type ECRIS by using these evaporators.

  15. Production of multicharged metal ion beams on the first stage of tandem-type ECRIS.

    PubMed

    Hagino, Shogo; Nagaya, Tomoki; Nishiokada, Takuya; Otsuka, Takuro; Muramatsu, Masayuki; Kitagawa, Atsushi; Sato, Fuminobu; Kato, Yushi

    2016-02-01

    Multicharged metal ion beams are required to be applied in a wide range of fields. We aim at synthesizing iron-endohedral fullerene by transporting iron ion beams from the first stage into the fullerene plasma in the second stage of the tandem-type electron cyclotron resonance ion source (ECRIS). We developed new evaporators by using a direct ohmic heating method and a radiation heating method from solid state pure metal materials. We investigate their properties in the test chamber and produce iron ions on the first stage of the tandem-type ECRIS. As a result, we were successful in extracting Fe(+) ion beams from the first stage and introducing Fe(+) ion beams to the second stage. We will try synthesizing iron-endohedral fullerene on the tandem-type ECRIS by using these evaporators.

  16. Statistical approach to studying radiation from multicharged ions in a plasma under coronal equilibrium conditions

    SciTech Connect

    Garanin, S. F.; Kravets, E. M.; Mamyshev, V. I.; Tokarev, V. A.

    2009-08-15

    Radiation spectra from a plasma with multicharged ions, z >> N >> 1(where z is the charge of an ion and N is the number of electrons in the ion) under coronal equilibrium conditions are considered in the quasiclassical approximation. In this case, the bremsstrahlung and recombination radiation can be described by simple quasiclassical formulas. The statistical model of an atom is used to study the high-frequency component of the line radiation spectra from ions ({h_bar}{omega} > I, where I is the ionization energy) that is produced in collisions of free plasma electrons with the electrons at deep levels of an ion and during radiative filling of the forming hole by electrons from higher levels (X-ray terms, characteristic radiation). The intensity of this high-frequency spectral component of the characteristic radiation coincides in order of magnitude with the bremsstrahlung and recombination radiation intensities. One of the channels of collisions of free electrons with a multicharged ion is considered that results in the excitation of the ion and in its subsequent radiative relaxation, which contributes to the low-frequency component of the line spectrum ({h_bar}{omega} < I). The total radiation intensity of this channel correlates fairly well with the results of calculating the radiation intensity from the multilevel coronal model. An analysis of the plasma behavior in the MAGO-IX experiment by two-dimensional MHD numerical simulations and a description of the experimental data from a DANTE spectrometer by the spectra obtained in this study shows that these experimental results cannot be explained if the D-T plasma is assumed to remain pure in the course of experiment. The agreement can be made better, how-ever, by assuming that the plasma is contaminated with impurities of copper and light elements from the wall.

  17. A multicharge ion source (Supernanogan) for the OLIS facility at ISAC/TRIUMF.

    PubMed

    Jayamanna, K; Wight, G; Gallop, D; Dube, R; Jovicic, V; Laforge, C; Marchetto, M; Leross, M; Louie, D; Laplante, R; Laxdal, R; McDonald, M; Wiebe, G J; Wang, V; Yan, F

    2010-02-01

    The Off-Line Ion Source (OLIS) [K. Jayamanna, D. Yuan, T. Kuo, M. MacDonald, P. Schmor, and G. Dutto, Rev. Sci. Instrum. 67, 1061 (1996); K. Jayamanna, Rev. Sci. Instrum. 79, 02711 (2008)] facility consists of a high voltage terminal containing a microwave cusp ion source, either a surface ion source or a hybrid surface-arc discharge ion source [K. Jayamanna and C. Vockenhuber, Rev. Sci. Instrum. 79, 02C712 (2008)], and an electrostatic switch that allows the selection of any one of the sources without mechanical intervention. These sources provide a variety of +1 beams up to mass 30 for Isotope Separator and ACcelerator (ISAC) [R. E. Laxdal, Nucl. Instrum. Methods Phys. Res. B 204, 400 (2003)] experiments, commissioning the accelerators, setting up the radioactive experiments, and for tuning the beam lines. The radio frequency quadrupole (RFQ) [M. Marchetto, Z. T. Ang, K. Jayamanna, R. E. Laxdal, A. Mitra, and V. Zvyagintsev, Eur. Phys. J. Spec. Top. 150, 241 (2005)] injector accelerator is a constant velocity machine designed to accept only 2 keV/u and the source extraction energy is limited to 60 kV. Further stripping is then needed downstream of the RFQ to inject the beam into the drift tube linac [M. Marchetto, Z. T. Ang, K. Jayamanna, R. E. Laxdal, A. Mitra, and V. Zvyagintsev, Eur. Phys. J. Spec. Top. 150, 241 (2005)] accelerator that requires A/q up to 6. Base on this constraints a multicharge ion source capable to deliver beams above mass 30 with A/q up to 6 was needed in order to reach full capability of the ISAC facility. A Supernanogan [C. Bieth et al., Nucleonika 48, S93 (2003)] multicharge ion source was then purchased from Pantechnik and was installed in the OLIS terminal. Commissioning and performance of the Supernanogan with some results such as emittance dependence of the charge states as well as charge state efficiencies are presented.

  18. A multicharge ion source (Supernanogan) for the OLIS facility at ISAC/TRIUMFa)

    NASA Astrophysics Data System (ADS)

    Jayamanna, K.; Wight, G.; Gallop, D.; Dube, R.; Jovicic, V.; Laforge, C.; Marchetto, M.; Leross, M.; Louie, D.; Laplante, R.; Laxdal, R.; McDonald, M.; Wiebe, G. J.; Wang, V.; Yan, F.

    2010-02-01

    The Off-Line Ion Source (OLIS) [K. Jayamanna, D. Yuan, T. Kuo, M. MacDonald, P. Schmor, and G. Dutto, Rev. Sci. Instrum. 67, 1061 (1996); K. Jayamanna, Rev. Sci. Instrum. 79, 02711 (2008)] facility consists of a high voltage terminal containing a microwave cusp ion source, either a surface ion source or a hybrid surface-arc discharge ion source [K. Jayamanna and C. Vockenhuber, Rev. Sci. Instrum. 79, 02C712 (2008)], and an electrostatic switch that allows the selection of any one of the sources without mechanical intervention. These sources provide a variety of +1 beams up to mass 30 for Isotope Separator and ACcelerator (ISAC) [R. E. Laxdal, Nucl. Instrum. Methods Phys. Res. B 204, 400 (2003)] experiments, commissioning the accelerators, setting up the radioactive experiments, and for tuning the beam lines. The radio frequency quadrupole (RFQ) [M. Marchetto, Z. T. Ang, K. Jayamanna, R. E. Laxdal, A. Mitra, and V. Zvyagintsev, Eur. Phys. J. Spec. Top. 150, 241 (2005)] injector accelerator is a constant velocity machine designed to accept only 2 keV/u and the source extraction energy is limited to 60 kV. Further stripping is then needed downstream of the RFQ to inject the beam into the drift tube linac [M. Marchetto, Z. T. Ang, K. Jayamanna, R. E. Laxdal, A. Mitra, and V. Zvyagintsev, Eur. Phys. J. Spec. Top. 150, 241 (2005)] accelerator that requires A/q up to 6. Base on this constraints a multicharge ion source capable to deliver beams above mass 30 with A/q up to 6 was needed in order to reach full capability of the ISAC facility. A Supernanogan [C. Bieth et al., Nucleonika 48, S93 (2003)] multicharge ion source was then purchased from Pantechnik and was installed in the OLIS terminal. Commissioning and performance of the Supernanogan with some results such as emittance dependence of the charge states as well as charge state efficiencies are presented.

  19. A multicharge ion source (Supernanogan) for the OLIS facility at ISAC/TRIUMF

    SciTech Connect

    Jayamanna, K.; Wight, G.; Gallop, D.; Dube, R.; Jovicic, V.; Laforge, C.; Marchetto, M.; Leross, M.; Louie, D.; Laplante, R.; Laxdal, R.; McDonald, M.; Wiebe, G. J.; Wang, V.; Yan, F.

    2010-02-15

    The Off-Line Ion Source (OLIS) [K. Jayamanna, D. Yuan, T. Kuo, M. MacDonald, P. Schmor, and G. Dutto, Rev. Sci. Instrum. 67, 1061 (1996); K. Jayamanna, Rev. Sci. Instrum. 79, 02711 (2008)] facility consists of a high voltage terminal containing a microwave cusp ion source, either a surface ion source or a hybrid surface-arc discharge ion source [K. Jayamanna and C. Vockenhuber, Rev. Sci. Instrum. 79, 02C712 (2008)], and an electrostatic switch that allows the selection of any one of the sources without mechanical intervention. These sources provide a variety of +1 beams up to mass 30 for Isotope Separator and ACcelerator (ISAC) [R. E. Laxdal, Nucl. Instrum. Methods Phys. Res. B 204, 400 (2003)] experiments, commissioning the accelerators, setting up the radioactive experiments, and for tuning the beam lines. The radio frequency quadrupole (RFQ) [M. Marchetto, Z. T. Ang, K. Jayamanna, R. E. Laxdal, A. Mitra, and V. Zvyagintsev, Eur. Phys. J. Spec. Top. 150, 241 (2005)] injector accelerator is a constant velocity machine designed to accept only 2 keV/u and the source extraction energy is limited to 60 kV. Further stripping is then needed downstream of the RFQ to inject the beam into the drift tube linac [M. Marchetto, Z. T. Ang, K. Jayamanna, R. E. Laxdal, A. Mitra, and V. Zvyagintsev, Eur. Phys. J. Spec. Top. 150, 241 (2005)] accelerator that requires A/q up to 6. Base on this constraints a multicharge ion source capable to deliver beams above mass 30 with A/q up to 6 was needed in order to reach full capability of the ISAC facility. A Supernanogan [C. Bieth et al., Nucleonika 48, S93 (2003)] multicharge ion source was then purchased from Pantechnik and was installed in the OLIS terminal. Commissioning and performance of the Supernanogan with some results such as emittance dependence of the charge states as well as charge state efficiencies are presented.

  20. Sputtering of Lunar Regolith Simulant by Protons and Multicharged Heavy Ions at Solar Wind Energies

    SciTech Connect

    Meyer, Fred W; Harris, Peter R; Taylor, C. N.; Meyer III, Harry M; Barghouty, N.; Adams Jr., J.

    2011-01-01

    We report preliminary results on sputtering of a lunar regolith simulant at room temperature by singly and multiply charged solar wind ions using quadrupole and time-of-flight (TOF) mass spectrometry approaches. Sputtering of the lunar regolith by solar-wind heavy ions may be an important particle source that contributes to the composition of the lunar exosphere, and is a possible mechanism for lunar surface ageing and compositional modification. The measurements were performed in order to assess the relative sputtering efficiency of protons, which are the dominant constituent of the solar wind, and less abundant heavier multicharged solar wind constituents, which have higher physical sputtering yields than same-velocity protons, and whose sputtering yields may be further enhanced due to potential sputtering. Two different target preparation approaches using JSC-1A AGGL lunar regolith simulant are described and compared using SEM and XPS surface analysis.

  1. (Physics of multicharged ions): Foreign trip report, September 12--23, 1988

    SciTech Connect

    Havener, C.C.

    1988-10-11

    This trip provided the traveler the opportunity to present to an international group of scientists recent experimental work using the ion-atom merged-beams apparatus at Oak Ridge. Discussions led to a better understanding of present results and to directions for the future. A tour of the laboratory of the Atomic Physics group at CEN-G offered a direct comparison between a recently established user facility there and our ECR facility at Oak Ridge. The workshop in Krakow presented the traveler the opportunity to present recent advances in the understanding of the neutralization of multicharged ions at surfaces. A significant part of the work in this field has been done at Oak Ridge. A tour of laboratories at Jagellonian University gave the traveler the opportunity to see first hand experimental facilities of a Soviet-bloc country.

  2. An analytic expression for the sheath criterion in magnetized plasmas with multi-charged ion species

    SciTech Connect

    Hatami, M. M.

    2015-04-15

    The generalized Bohm criterion in magnetized multi-component plasmas consisting of multi-charged positive and negative ion species and electrons is analytically investigated by using the hydrodynamic model. It is assumed that the electrons and negative ion density distributions are the Boltzmann distribution with different temperatures and the positive ions enter into the sheath region obliquely. Our results show that the positive and negative ion temperatures, the orientation of the applied magnetic field and the charge number of positive and negative ions strongly affect the Bohm criterion in these multi-component plasmas. To determine the validity of our derived generalized Bohm criterion, it reduced to some familiar physical condition and it is shown that monotonically reduction of the positive ion density distribution leading to the sheath formation occurs only when entrance velocity of ion into the sheath satisfies the obtained Bohm criterion. Also, as a practical application of the obtained Bohm criterion, effects of the ionic temperature and concentration as well as magnetic field on the behavior of the charged particle density distributions and so the sheath thickness of a magnetized plasma consisting of electrons and singly charged positive and negative ion species are studied numerically.

  3. Beam extraction from a laser-driven multicharged ion source (abstract)

    NASA Astrophysics Data System (ADS)

    Anderson, O. A.; Logan, B. Grant

    1998-02-01

    A newly proposed type of multicharged ion source has several potential advantages over existing types and a number of useful applications. The basic principle is that multiphoton absorption in an intense uniform laser focus can give multiple charge states of high purity (Ref. Reference 1). Thus, charge state separation downstream is simplified or made unnecessary. Another advantage is that large currents (hundreds of amperes) can be extracted. This type of source could be used for heavy-ion fusion drivers (see Ref. Reference 1) or storage rings. There are also industrial application such as materials processing. We describe conceptual design studies for several specific cases. For example, we discuss extraction and focusing of a 4.1 MV, 144 A beam of Xe16+ ions from an expanding plasma created by an intense laser. The maximum duration of the beam pulse is determined by the total charge in the plasma, while the practical pulse length is determined by the range of plasma radii over which good beam optics can be achieved. The initially diverging beam can be refocused to a small radius or made parallel by a combination of electrostatic and solenoid focusing. Our design studies are carried out first with an envelope code to determine the proper focusing parameters and then with a self-consistent particle code to optimize the beam quality. We present results from both codes and discuss several applications of this type of ion source.

  4. Spectr-W3 online database on atomic properties of multicharged ions

    NASA Astrophysics Data System (ADS)

    Skobelev, I. Yu; Loboda, P. A.; Faenov, A. Ya; Gagarin, S. V.; Kozlov, A. I.; Morozov, S. V.; Pikuz, S. A.; Pikuz, T. A.; Popova, V. V.

    2015-11-01

    The Spectr-W3 information-reference system was developed in 2001-2013 and realized as an online Web resource based on the factual atomic database Spectr-W3. The information accumulated in the Spectr-W3 atomic database contains about 450,000 records and includes the experimental and theoretical data on ionization potentials, energy levels, wavelengths, radiation transition probabilities, and oscillator strengths, and the parameters of analytical approximations of electron-collisional cross-sections and rates for atoms and ions. Those data were extracted from publications in physical journals, proceedings of the related conferences, special-purpose publications on atomic data, provided directly by authors. The information is supplied with references to the original sources and comments, elucidating the details of experimental measurements or calculations. To date, the Spectr-W3 atomic database is still the largest factual database in the world, containing the information on spectral properties of multicharged ions. In 2014, the new stage in the development of the Spectr-W3 atomic database started. The purpose of this stage is the creation of a new information section of the Spectr-W3 database. This section would contain the information on the x-ray emission spectrograms registered from various plasma sources.

  5. End-point energies of electrons ejected during Auger neutralization of slow, multicharged ions near metal surfaces

    NASA Astrophysics Data System (ADS)

    Hughes, R. H.; Wattuhewa, Garvin; Miller, R. D.; Ye, X. M.; Pederson, D. O.

    1987-12-01

    A study has been done of the end-point energies of electrons ejected during Auger neutralization of slow, multicharged ions near metal surfaces. The study includes a wide variety of ions. Experimental results are presented for Alz+ and Cn+ ions incident on a gold surface, where z=2-5 and n=2-5. Ions from a laser-ion source are processed to produce ion pulses with incident energies ranging from 40 to 280 eV/charge. Data published by Hagstrum for 200-eV He2+, Nen+, Arn+, Krn+, and Xen+, on tungsten, where n=2 and 3, are analyzed along with the work of Varga, Hofer, and Winter for low-energy Ne2+, Ar2+, Ar3+, Kr2+, and Xe2+ on tungsten. It is concluded that the high-energy end of the Auger emission is dominated by single-electron capture by the ion and an internal conversion process involving direct coupling of optically allowed transitions in the lower-lying excited states of the singly neutralized ion to the top of the conduction band of the metal target. It is shown that a considerable fraction of the neonlike Al3+ ions from the laser-ion source are in a metastable state and are neutralized through autoionization.

  6. A stored-ion target for x-ray spectroscopy of multicharged ions

    SciTech Connect

    Kanter, E.P.

    1996-08-01

    With the evolution of the new third generation synchrotron radiation sources providing intense beams of hard x-rays, it is natural to consider exploiting these to investigate the 3-body Coulomb problem. The atomic physics community could advance this field considerably by developing general techniques to investigate the x-ray spectroscopy of heliumlike ions. To do so, however, requires the development of a target of such ions with sufficient density to permit photoexcitation studies in the hard x-ray regime. A possible scheme to achieve this is described. Such a target system would permit x-ray studies with exotic species such as highly charged atomic ions, size-selected cluster ions, and atomic and molecular negative ions which have hitherto been impractical to study with conventional techniques.

  7. Theoretical investigations of the IO,q+ (q = 2, 3, 4) multi-charged ions: Metastability, characterization and spectroscopy

    NASA Astrophysics Data System (ADS)

    Hammami, H.; Yazidi, O.; Ben El Hadj Rhouma, M.; Al Mogren, M. M.; Hochlaf, M.

    2014-07-01

    Using ab initio methodology, we studied the IOq+ (q = 2, 3, 4) multi-charged ions. Benchmark computations on the IO(X2Π) neutral species allow validate the current procedure. For IO2+, several potential wells were found on the ground and the electronic excited states potentials with potential barriers with respect to dissociation, where this dication can exist in the gas phase as long-lived metastable molecules. We confirm hence the recent observation of the dication by mass spectrometry. Moreover, we predict the existence of the metastable IO3+ trication, where a shallow potential well along the IO internuclear distance is computed. This potential well supports more than 10 vibrational levels. The IO3+ excited states are repulsive in nature, as well as the computed potentials for the IO4+ tetracation. For the bound states, we give a set of spectroscopic parameters including excitation transition energies, equilibrium distances, harmonic and anharmonic vibrational terms, and rotational constants. At the MRCI + Q/aug-cc-pV5Z(-PP) level, the adiabatic double and triple ionization energies of IO are computed to be ˜28.1 eV and ˜55.0 eV, respectively.

  8. Theoretical investigations of the IO,{sup q+} (q = 2, 3, 4) multi-charged ions: Metastability, characterization and spectroscopy

    SciTech Connect

    Hammami, H.; Yazidi, O.; Ben El Hadj Rhouma, M.; Al Mogren, M. M.; Hochlaf, M.

    2014-07-07

    Using ab initio methodology, we studied the IO{sup q+} (q = 2, 3, 4) multi-charged ions. Benchmark computations on the IO(X{sup 2}Π) neutral species allow validate the current procedure. For IO{sup 2+}, several potential wells were found on the ground and the electronic excited states potentials with potential barriers with respect to dissociation, where this dication can exist in the gas phase as long-lived metastable molecules. We confirm hence the recent observation of the dication by mass spectrometry. Moreover, we predict the existence of the metastable IO{sup 3+} trication, where a shallow potential well along the IO internuclear distance is computed. This potential well supports more than 10 vibrational levels. The IO{sup 3+} excited states are repulsive in nature, as well as the computed potentials for the IO{sup 4+} tetracation. For the bound states, we give a set of spectroscopic parameters including excitation transition energies, equilibrium distances, harmonic and anharmonic vibrational terms, and rotational constants. At the MRCI + Q/aug-cc-pV5Z(-PP) level, the adiabatic double and triple ionization energies of IO are computed to be ∼28.1 eV and ∼55.0 eV, respectively.

  9. Theoretical investigations of the IO,q+ (q = 2, 3, 4) multi-charged ions: metastability, characterization and spectroscopy.

    PubMed

    Hammami, H; Yazidi, O; Ben El Hadj Rhouma, M; Al Mogren, M M; Hochlaf, M

    2014-07-01

    Using ab initio methodology, we studied the IO(q+) (q = 2, 3, 4) multi-charged ions. Benchmark computations on the IO(X(2)Π) neutral species allow validate the current procedure. For IO(2+), several potential wells were found on the ground and the electronic excited states potentials with potential barriers with respect to dissociation, where this dication can exist in the gas phase as long-lived metastable molecules. We confirm hence the recent observation of the dication by mass spectrometry. Moreover, we predict the existence of the metastable IO(3+) trication, where a shallow potential well along the IO internuclear distance is computed. This potential well supports more than 10 vibrational levels. The IO(3+) excited states are repulsive in nature, as well as the computed potentials for the IO(4+) tetracation. For the bound states, we give a set of spectroscopic parameters including excitation transition energies, equilibrium distances, harmonic and anharmonic vibrational terms, and rotational constants. At the MRCI + Q/aug-cc-pV5Z(-PP) level, the adiabatic double and triple ionization energies of IO are computed to be ~28.1 eV and ~55.0 eV, respectively.

  10. Generation of multi-charged high current ion beams using the SMIS 37 gas-dynamic electron cyclotron resonance (ECR) ion source

    SciTech Connect

    Dorf, M. A.; Zorin, V. G.; Sidorov, A. V.; Bokhanov, A. F.; Izotov, I. V.; Razin, S. V.; Skalyga, V. A.

    2013-06-02

    A gas-dynamic ECR ion source (GaDIS) is distinguished by its ability to produce high current and high brightness beams of moderately charged ions. Contrary to a classical ECR ion source where the plasma confinement is determined by the slow electron scattering into an empty loss-cone, the higher density and lower electron temperature in a GaDIS plasma lead to an isotropic electron distribution with the confinement time determined by the prompt gas-dynamic flow losses. As a result, much higher ion fluxes are available, however a decrease in the confinement time of the GaDIS plasma lowers the ion charge state. The gas-dynamic ECR ion source concept has been successfully realized in the SMIS 37 experimental facility operated at the Institute of Applied Physics, Russia. The use of high-power (~100 kW) microwave (37.5 GHz) radiation provides a dense plasma (~1013 cm-3) with a relatively low electron temperature (~50- 100 eV) and allows for the generation of high current (~1 A/cm2) beams of multi-charged ions. In this work we report on the present status of the SMIS 37 ion source and discuss the advanced numerical modeling of ion beam extraction using the particle-in-cell code WARP

  11. Electron-impact ionization of multicharged ions at ORNL: 1985--1992

    SciTech Connect

    Gregory, D.C.; Bannister, M.E.

    1994-07-01

    Absolute cross sections are presented in graphs and tables for single ionization of forty-one ions, multiple ionization of four ions, and for dissociation and ionization of two molecular ions by electron impact. This memo is the third in a series of manuscripts summarizing previously published as well as unpublished ionization cross section measurements at ORNL; contents of the two previous memos are also referenced in this work. All work tabulated in this memo involved ion beams generated in the ORNL-ECR ion source and utilized the ORNL electron-ion crossed beams apparatus. Target ions range from atomic number Z = 8 (oxygen) to Z = 92 (uranium) in initial charge states from +1 to +16. Electron impact energies typically range from threshold to 1500 eV.

  12. MONO1001: A source for singly charged ions applied to the production of multicharged fullerene beams

    NASA Astrophysics Data System (ADS)

    Maunoury, L.; Andersen, J. U.; Cederquist, H.; Huber, B. A.; Hvelplund, P.; Leroy, R.; Manil, B.; Pacquet, J. Y.; Pedersen, U. V.; Rangamma, J.; Tomita, S.

    2004-05-01

    The present article reports on a recent study of the production of multiply charged fullerene beams based on an electron cyclotron resonance (ECR) ion source (ECRIS). As collision studies in fundamental physics are demanding intense beams of multiply charged ions of small molecules, clusters, and particularly of fullerenes, we have further developed the ion source ECRIS MONO1000 [P. Jardin et al., Rev. Sci. Instrum. 73, 789 (2002)], originally devoted to produce singly charged ions, towards the production of multiply charged fullerene beams. In this article, the test measurements performed at the Electrostatic Ion Storage Ring Århus rf power (ELISA) facility will be described. Typical mass spectra (from pure C60 and C70 powder) will be shown and the influence of several source parameters (rf power, support gas, gas pressure,…) will be discussed specifying the conditions necessary for an optimum ion source operation.

  13. Projectile image acceleration, neutralization and electron emission during grazing interactions of multicharged ions with Au(110)

    SciTech Connect

    Meyer, F.W.; Folkerts, L.; Folkerts, H.O.; Schippers, S. |

    1995-03-01

    Recent Oak Ridge work is summarized on projectile energy gain by image charge acceleration, scattered ion charge distributions, and K-Auger electron emission during low energy grazing interactions of highly charged Pb, I, O, and Ar ions with a Au(110) surface.

  14. First multicharged ion irradiation results from the CUEBIT facility at Clemson University

    SciTech Connect

    Shyam, R.; Kulkarni, D. D.; Field, D. A.; Srinadhu, E. S.; Harriss, J. E.; Cutshall, D. B.; Harrell, W. R.; Sosolik, C. E.

    2015-01-09

    A new electron beam ion trap (EBIT) based ion source and beamline were recently commissioned at Clemson University to produce decelerated beams of multi- to highly-charged ions for surface and materials physics research. This user facility is the first installation of a DREEBIT-designed superconducting trap and ion source (EBIS-SC) in the U.S. and includes custom-designed target preparation and irradiation setups. An overview of the source, beamline, and other facilities as well as results from first measurements on irradiated targets are discussed here. Results include extracted charge state distributions and first data on a series of irradiated metal-oxide-semiconductor (MOS) device targets. For the MOS devices, we show that voltage-dependent capacitance can serve as a record of the electronic component of ion stopping power for an irradiated, encapsulated oxide target.

  15. First multicharged ion irradiation results from the CUEBIT facility at Clemson University

    NASA Astrophysics Data System (ADS)

    Shyam, R.; Kulkarni, D. D.; Field, D. A.; Srinadhu, E. S.; Cutshall, D. B.; Harrell, W. R.; Harriss, J. E.; Sosolik, C. E.

    2015-01-01

    A new electron beam ion trap (EBIT) based ion source and beamline were recently commissioned at Clemson University to produce decelerated beams of multi- to highly-charged ions for surface and materials physics research. This user facility is the first installation of a DREEBIT-designed superconducting trap and ion source (EBIS-SC) in the U.S. and includes custom-designed target preparation and irradiation setups. An overview of the source, beamline, and other facilities as well as results from first measurements on irradiated targets are discussed here. Results include extracted charge state distributions and first data on a series of irradiated metal-oxide-semiconductor (MOS) device targets. For the MOS devices, we show that voltage-dependent capacitance can serve as a record of the electronic component of ion stopping power for an irradiated, encapsulated oxide target.

  16. Electron-Impact Ionization of Multicharged Ions: Cross-Sections Data from Oak Ridge National Laboratory (ORNL) and the Controlled Fusion Atomic Data Center (CFADC)

    DOE Data Explorer

    This website presents experimental ionization cross sections measured using the Electron-Ion Crossed Beams apparatus in the Multicharged Ion Research Facility (MIRF) at the Physics Division of Oak Ridge National Laboratory (ORNL). The data are given in both graphical and tabular form along with the reference to the original publication of the experimental results. Also presented in the figures are theoretical cross sections supporting the experiments. For details of the theoretical work, refer to the original publication given for the particular experiment. These pages are based primarily on three technical memorandums issued by ORNL: 1(D. H. Crandall, R. A. Phaneuf, and D. C. Gregory, Electron Impact Ionization of Multicharged Ions, ORNL/TM-7020, Oak Ridge National Laboratory, 1979; 2) D. C. Gregory, D. H. Crandall, R. A. Phaneuf, A. M. Howald, G. H. Dunn, R. A. Also presented are more recent (1993-present) data, both published and unpublished. The data pages feature dynamic plotting, allowing the user to choose which sets of data to plot and zoom in on regions of interest within the plot. [Taken from http://www-cfadc.phy.ornl.gov/xbeam/index.html

  17. Role of Auger-type emission from diatomic molecular targets interacting with fast multicharged ions

    SciTech Connect

    Tachino, Carmen A.; Galassi, Mariel E.; Rivarola, Roberto D.

    2009-07-15

    Multiple electron emission in collisions between bare multiply charged ions and diatomic molecules is studied. The role played by Auger-type emission in cross sections for fixed number of ejected electrons is investigated. It is shown that this postcollisional reaction gives the main contribution to these cross sections at high enough impact velocities. This behavior is accentuated as the ionization degree increases.

  18. Total single electron capture cross sections for collisions of multicharged ions with He atoms

    NASA Astrophysics Data System (ADS)

    Rahmanian, M.; Shojaei, F.; Fathi, R.

    2016-09-01

    The three-body boundary corrected Born distorted wave method is utilized to compute the total cross sections for single electron capture in the collisions of the fast ions ({{{H}}}1+, He{}2+, Li{}3+, {{{B}}}5+ and {{{C}}}6+) with helium targets in their ground states. Both post and prior forms of the transition amplitude are obtained in terms of two-dimensional integrals and the total cross sections are computed via three-dimensional numerical integrations. The present results show reasonable agreement with the measurements and three- and four-body theoretical computations, especially at higher incident energies.

  19. Electron emission from polycrystalline lithium fluoride bombarded by slow multicharged ions

    NASA Astrophysics Data System (ADS)

    Vana, M.; Aumayr, F.; Varga, P.; Winter, H. P.

    1995-06-01

    Total electron yields have been determined from electron emission statistics measured for impact of H +, N q+ ( q = 1, 5, 6) and Ar q+ ( q = 1, 3, 6, 9) on clean, polycrystalline lithium fluoride. Ion impact energies have been varied from almost zero up to 10 × q keV. The obtained total electron yields deviate considerably from available data derived via ion- and electron current measurements for LiF single crystal targets. Our results are explained by comparison with a recent model for MCI induced potential electron emission from clean metal surfaces, which has been properly adapted, available theory for kinetic electron emission from alkalihalide surfaces, and by considering also measured secondary electron yields for LiF. Dependences of the electron emission statistics and -yields on projectile impact energy and -charge differ strongly from corresponding properties for clean metal surfaces, which can be explained from the different roles of potential- and kinetic emission and, in particular, a relatively stronger contribution from secondary electron emission induced by fast electrons from finally neutralising projectiles inside the LiF bulk.

  20. Formation of multi-charged ion beams by focusing effect of mid-electrode on electron cyclotron resonance ion source

    SciTech Connect

    Imai, Youta Kimura, Daiju; Kurisu, Yosuke; Nozaki, Dai; Yano, Keisuke; Kumakura, Sho; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki

    2014-02-15

    We are constructing a tandem type electron cyclotron resonance ion source (ECRIS) and a beam line for extracting ion beams. The ion beam is extracted from the second stage by an accel-decel extraction system with a single-hole and the ion beam current on each electrode is measured. The total ion beam current is measured by a faraday cup downstream the extraction electrodes. We measure these currents as a function of the mid-electrode potential. We also change the gap length between electrodes and perform similar measurement. The behaviors of these currents obtained experimentally against the mid-electrode potential show qualitatively good agreement with a simple theoretical consideration including sheath potential effects. The effect of mid-electrode potential is very useful for decreasing the beam loss for enhancing ion beam current extracted from ECRIS.

  1. High-resolution x-ray spectroscopy of multicharged argon and krypton ions using a laser-produced x-ray source with a gas-puff target

    NASA Astrophysics Data System (ADS)

    Bartnik, Andrzej; Dyakin, Vladimir M.; Faenov, Anatoly Y.; Fiedorowicz, Henryk; Jarocki, Roman; Nilsen, Joseph; Osterheld, Albert L.; Skobelev, Igor Y.; Szczurek, Miroslaw

    1997-10-01

    A hot and dense plasma can be produced by high-power laser irradiation of a high-pressure gas puff target. The plasma emits strong x-ray radiation in low photon-energy range (soft x-rays and XUV radiation) and is considered to be used as a debrisless laser-produced x-ray source. It was shown that the laser-irradiated gas puff plasma is an ideal source for the high-resolution spectroscopic studies of complex spectra of the multicharged ions. This paper reports our investigations of x-ray spectra of heliumlike argon and neonlike krypton ions. The gas puff targets were created with the use of a specially designed high-pressure solenoid valve operating at a backing pressure up to 15 at and quipped with a sonic-type circular nozzle of 0.5 mm in diameter. Parameters of the gas puff targets were measured using x-ray shadowgraphy and laser interferometry. To irradiate the gas puff targets we have used a Nd:glass laser, which generates 10 J pulses in 1 ns FWHM. The laser beam was focused onto the gas puff target perpendicularly in respect to the flow of gas using an aspherical lens. The diameter of a laser beam in the focus were about 100 micrometers , what ensured the radiation power density to be of order of 1014 W/cm2. To measure x-ray spectra emitted by a laser-irradiated gas puff target we have used a simple focusing crystal spectrographs with a mica crystal curved into a spherical surface of radius R equals 100 mm. The spectra were recorded on Kodak RAR 2495 x-ray commercial film. The high resolving power of the spectrograph of about (lambda) /(Delta) (lambda) equals 10000 permitted high-precision wavelength spectral measurements. The measured x-ray spectra have the small spectra width of the observed lines associated with the low expansion velocity of the laser- irradiated gas puff plasma. Dielectronic sodiumlike satellites to neonlike krypton resonance lines have measured for the first time. High-resolution spectra of heliumlike argon were also obtained. The

  2. Multicharged ion source based on Penning-type discharge with electron cyclotron resonance heating by millimeter waves.

    PubMed

    Vodopyanov, A V; Izotov, I V; Mansfeld, D A; Yushkov, G Yu

    2012-02-01

    We suggest a Penning-type discharge as a trigger discharge for fast development of pulsed electron cyclotron resonance plasma. The Penning-type discharge glows at a low pressure as needed. Gyrotron radiation (75 GHz, 200 kW, 1 ms) was used for plasma heating. Fully striped helium ions were demonstrated, average charge of ions in the plasma was ≈ 2. Experiment and calculations show that high charge states of heavier gases require lower initial pressure and longer development time. Only moderate charge states are achievable in this pulsed scheme.

  3. Excitation of atoms and molecules in collisions with highly charged ions

    SciTech Connect

    Watson, R.L.

    1992-03-01

    This report discusses research of multicharged nitrogen, oxygen and carbon monoxide molecular ions produced with collision with multicharged argon ions. Properties like ionization, dissociation, and excitation are investigated. (LSP)

  4. Excitation of atoms and molecules in collisions with highly charged ions. Progress report, January 1, 1991--March 1, 1992

    SciTech Connect

    Watson, R.L.

    1992-03-01

    This report discusses research of multicharged nitrogen, oxygen and carbon monoxide molecular ions produced with collision with multicharged argon ions. Properties like ionization, dissociation, and excitation are investigated. (LSP)

  5. Kinetic and Potential Sputtering Enhancements of Lunar Regolith Erosion: The Contribution of the Heavy Multicharged (Minority) Solar Wind Constituents

    NASA Technical Reports Server (NTRS)

    Meyer, F. W.; Barghouty, A. F.

    2012-01-01

    We report preliminary results for H+, Ar+1, Ar+6 and Ar+9 ion sputtering of JSC-1A lunar regolith simulant at solar wind velocities, obtain ed at the ORNL Multicharged Ion Research Facility using quadrupole ma ss spectrometry. The multi-charged Ar ions were used as proxies for i ntermediate mass solar wind multicharged ions. Prior to the Ar beam e xposures, the sample was exposed to high fluence H+ irradiation to si mulate H-loading due to the dominant solar wind constituent. A x80 en hancement of oxygen sputtering by Ar+ over same velocity H+ was measu red and an additional x2 increase for Ar+9 over same velocity Ar+ was demonstrated, giving clear evidence of the importance of potential s puttering by multicharged ions. This enhancement was observed to pers ist to the maximum fluences investigated (approx 10(exp 16)/sq cm). As discussed in a companion abstract by N. Barghouty, such persistent s puttering enhancement has significant implications on weathering and aging of lunar regolith. In addition, XPS measurements showed strong evidence of Fe reduction for those target areas that had been exposed to high fluence Ar+ and Ar+8 beams. Preferential oxidation of the Fe -reduced beam-exposed regions during transfer to the XPS system led t o enhanced O concentrations in those regions as well. On the basis of these very promising preliminary results, a NASA-LASER project on mo re extensive measurements was recently selected for funding. The prop osal expands the collaboration with NASA-MSFC for the simulation effort, and adds a new collaboration with NASA-GSFC for lunar mission-rele vant measurements.

  6. Prise en compte de l'anisotropie des collisions ion-atome sur le transport des ions par simulation de Monte-Carlo

    NASA Astrophysics Data System (ADS)

    Hennad, A.; Eichwald, O.; Yousfi, M.; Lamrous, O.

    1997-09-01

    This paper is devoted to the determination of the differential and integral collision cross sections needed for the calculation of the transport coefficient of ions in weakly ionized gases. In the case of Ar^+/Ar system and for energy interval varying up to 100 eV, the cross sections are obtained from the interaction potential of polarization for low energies and of Lennard-Jones for higher energies. The calculation method of the collision cross sections based on the classical mechanics has been first validated from comparisons of measured and calculated differential cross sections. Then, these cross sections have been used in a Monte-Carlo code for simulation of the transport of Ar^+ ions in Ar gas at room temperature (300 K). The obtained transport coefficients (ion mobility, drift velocity and diffusion coefficient) are in good agreement with the drift tube measurements given in the literature thus confirming the validity of the method of collision cross section calculation. Cet article est consacré à la détermination des sections efficaces différentielles et intégrales ion-atome nécessaires au calcul des coefficients de transport des ions dans les gaz faiblement ionisés. Dans le cas du système Ar^+/Ar et pour des intervalles d'énergie allant jusqu'à quelques dizaines d'eV, les sections efficaces sont obtenues à partir des potentiels d'interaction de polarisation pour les faibles énergies et de Lennard-Jones pour les énergies plus élevées. La méthode de calcul des sections efficaces basée sur la mécanique classique a d'abord été validée par comparaison des sections efficaces différentielles mesurées et calculées. Ensuite, ces sections efficaces ont été utilisées dans un code de simulation statistique de Monte-Carlo du transport des ions Ar^+ dans l'Argon à la température ambiante (300 K). Les coefficients de transport (vitesse de dérive, mobilité ionique et coefficient de diffusion) obtenus sont en bon accord avec les mesures de

  7. Etude de la photosensibilite dans la silice implantee avec des ions de haute energie

    NASA Astrophysics Data System (ADS)

    Verhaegen, Marc

    La photosensibilite est la propriete par laquelle une materiau donne voit son indice de refraction changer sous l'effet d'une exposition lumineuse. Malgre le nombre croissant de dispositif base sur ce phenomene, les mecanismes a la base de la photosensibilite sont encore debattus. Nous apportons dans cette these un eclairage original sur ce sujet en etudiant la matrice de silice pure non dopee rendue photosensible par implantation d'ion de haute energie. L'implantation d'ions silicium de S MeV modifie l'indice de refraction principalement en densifiant une couche mince dont l'epaisseur est de l'ordre de quelques microns. Nos mesures montrent qu'un guide plan supportant les modes TEi et TMi (i = 0,1) est forme et que l'indice effectif du mode TE0 suit l'evolution de la densification en fonction de la dose de silicium implantee. Nous montrerons egalement que l'augmentation d'indice et la densification produites par implantation atteignent un palier pour une dose de 3 x 1014Si/cm 2, alors que la production de defauts par implantation atteint son palier pour une dose plus faible d'un ordre de grandeur soit 3 x 1013Si/cm2. Le profil d'indice longitudinal produit par l'implantation ionique est calcule a partir des mesures des indices effectifs des modes guides. Ce profil suggere que l'augmentation d'indice comprend une contribution dues collisions et une contribution dues aux pertes d'energie par ionisation. La contribution des pertes par ionisation influence significativement le profil d'indice pour des valeurs de pertes d'energie par unite de longueur (dE/dx) de l'ordre de 2 keV/nm. Lorsque la silice implantee est soumise a un rayonnement ultraviolet d'un laser a excimeres, il en resulte une diminution d'indice de refraction de l'ordre de 10-3 avec une efficacite plus grande si la longueur d'onde d'exposition est 193nm (ArF) plutot que 248nm (KrF). Deux regimes d'exposition lumineuse de la silice implantee a 193nm sont observes. Le premier regime produit une diminution

  8. Relativistic Calculating the Spectral Lines Hyperfine Structure Parameters for Heavy Ions

    SciTech Connect

    Khetselius, O. Yu.

    2008-10-22

    The energies and constants of the hyperfine structure, derivatives of the one-electron characteristics on nuclear radius, nuclear electric quadrupole, magnetic dipole moments for some Li-like multicharged ions are calculated.

  9. Protection des ions organiques contre les dommages induits a l'ADN par les electrons de basse energie

    NASA Astrophysics Data System (ADS)

    Dumont, Ariane

    Il a ete demontre que les electrons de basse energie (EBE) peuvent induire des cassures simple brin (CSB) a l'ADN, via la formation d'anions transitoires qui decroissent par attachement dissociatif, ou dans d'autres etats electroniques dissociatifs menant a la fragmentation. Afin d'effectuer une etude complete des effets des electrons de basse energie sur la matiere biologique, il est necessaire de comprendre leur mecanismes d'interaction non seulement avec l'ADN, mais avec les constituants de son environnement. Les histones sont une composante importante de l'environnement moleculaire de l'ADN. Leur charge positive leur permet de s'associer aux groupements phosphate anionique de l'ADN. Le role principal de ces proteines basiques consiste a organiser l'ADN et l'empaqueter afin de former la chromatine. Les cations sont une autre composante importante de la cellule; ils jouent un role dans la stabilisation de la conformation B de l'ADN in vitro par leurs interactions avec les petits et grands sillons de l'ADN, ainsi qu'avec le groupement phosphate charge negativement. Avec les histones, ils participent egalement a la compaction de l'ADN pour former la chromatine. Cette etude a pour but de comprendre comment la presence d'ions organiques (sous forme de Tris et d'EDTA) a proximite de l'ADN modifie le rendement de cassures simple brin induit par les electrons de basse energie. Le Tris et l'EDTA ont-ete choisis comme objet d'etude, puisqu'en solution, ils forment le tampon standard pour solubiliser l'ADN dans les experiences in vitro (10mM Tris, 1mM EDTA). De plus, la molecule Tris possede un groupement amine alors que l'EDTA possede 4 groupements carboxyliques. Ensembles, ils peuvent se comporter comme un modele simple pour les acides amines. Le ratio molaire de 10 :1 de Tris par rapport a l'EDTA a pour but d'imiter le comportement des histones qui sont riches en arginine et lysine, acides amines possedant un groupement amine charge positivement additionnel. Des films d

  10. Production of Highly Charged Ga Ions from Organic Metal Comppound Using the Liquid-He-Free Superconducting Electron Cyclotron Resonance Ion Source at RIKEN

    NASA Astrophysics Data System (ADS)

    Higurashi, Yoshihide; Nakagawa, Takahide; Kidera, Masanori; Kageyama, Tadashi; Kase, Masayuki; Yano, Yasushige

    2002-08-01

    We successfully produced the multi-charged Ga ions using metal ions from volatile compounds (MIVOC) method from liquid-He-free super conducting electron cyclotron resonance ion source at RIKEN (RAMSES). The beam intensities of Ga15+ and Ga16+ ions were 5 and 4 eμA at the injected microwave power of 200 W, respectively.

  11. Excrétion rénale des ions divalents après homotransplantation rénale

    PubMed Central

    Cartier, F.; Popovtzer, M. M.; Robinette, J.; Pinggera, W. F.; Halgrimson, C. G.; Starzl, T. E.

    2010-01-01

    RÉSUMÉ L’élimination rénale des ions divalents, celle du Na et du K, ont été étudiées de façon comparative dans les suites immédiates de l’homotransplantation rénale chez 6 patients. Durant la période initiale polyurique (> 3ml/mn), le taux d’excrétion du Ca filtré (Cca/Ccr), du Mg, du P, du Na et du K, est élevé et il existe une corrélation étroite et quasi constante entre l’élimination du Ca, du Mg et du Na ; la corrélation n’est pas constante entre l’élimination du Na et du K, du Mg et du K. Pendant les deux jours suivants, le taux d’excrétion diminue, sauf pour le P ; il existe encore une corrélation entre l’excrétion du Ca, du Mg et du Na, non entre celle du Na et du K, du Mg et du K. L’excrétion du Ca l’emporte sur celle du Na au cours de la première période, non au cours de la seconde. A la lumière de ces données, on envisage l’intervention possible de divers facteurs, tels l’inflation hydrosique et l’hyperazotémie préalables, l’ischémie rénale contemporaine de la transplantation, les effets de la dénervation rénale, du traitement cortisonique, de l’hyperparathyroïdie et ceux des modifications circulatoires rénales. PMID:4574592

  12. Etude du mecanisme de predissociation de l'ion moleculaire de protoxyde d'azote par la mesure de l'energie cinetique des fragments de l'oxyde nitrique et de l'oxygene

    NASA Astrophysics Data System (ADS)

    Delisle, Claude

    La reaction N2 + O+ ↔ NO + + N, laquelle joue un role important dans la physique de la haute atmosphere, a ete le sujet de plusieurs etudes. Bien que cette reaction ait ete l'objet d'une quantite importante de travaux, ces derniers ne permettent toutefois pas de comprendre entierement le mecanisme d'un point de vue quantique, particulierement les niveaux d'energie excites des fragments qui permettent cette reaction. Puisque cette reaction n'est pas tres facile a reproduire en laboratoire, nous avons utilise la spectroscopie laser sur faisceaux d'ions rapides afin d'explorer les limites de dissociation de l'ion moleculaire intermediaire de cette reaction, a savoir l'ion N2O+. Le faisceau d'ions N2O+ rapides, apres excitation de l'ion moleculaire vers un niveau predissocie de l'etat A2Sigma+, se dissocie pour produire les fragments ioniques O+ et NO+. Par la mesure de la variation du nombre de fragments ioniques en fonction de l'energie cinetique des ions N2O+, nous avons enregistre les spectres de predissociation de l'ion N2O+. Lorsque c'etait possible, nous avons procede a l'analyse de ces spectres de dissociation afin d'en tirer les constantes moleculaires. Pour certaines des transitions rotationnelles intenses, nous avons mesure l'energie cinetique acquise par les fragments lors de la predissociation de l'ion N 2O+. Afin d'analyser les distributions en energie cinetique, nous avons developpe une simulation de l'experience en considerant, entre autres choses, la position des niveaux de vibration et de rotation des fragments diatomiques de chacune des limites de dissociation de N2O+. Les resultats de l'analyse sont exprimes en termes de population des niveaux de vibration des fragments diatomiques pour une distribution donnee de la population des niveaux de rotation des fragments. Les resultats ainsi obtenus, montrent que les fragments diatomiques sont produits dans des niveaux de vibration fortement excites. De tels niveaux d'excitation ne correspondent pas aux

  13. Scaling for state-selective charge exchange due to collisions of multicharged ions with hydrogen

    NASA Astrophysics Data System (ADS)

    Jorge, A.; Illescas, Clara; Miraglia, J. E.; Gravielle, M. S.

    2015-12-01

    In this article we evaluate state-resolved charge exchange cross sections for Be{}4+, {{{B}}}5+, {{{C}}}6+, {{{N}}}7+, and {{{O}}}8+ projectiles colliding with atomic hydrogen employing two different methods: the classical trajectory Monte Carlo and the eikonal impulse approximations. These cross sections are used to extend previously derived scaling laws for n-, nl-, and nlm-distributions to highly excited final levels with 4≤slant n≤slant 9, covering energies in the range 50-2000 {{keV}}/ amu. Present total and partial capture cross sections are in agreement with available experimental and theoretical data for these collision systems. Besides, the proposed scaling rules are also verified by other theories, becoming a useful instrument for plasma research.

  14. Scaling for state-selective charge exchange due to collisions of multicharged ions with hydrogen

    NASA Astrophysics Data System (ADS)

    Jorge, A.; Illescas, Clara; Miraglia, J. E.; Gravielle, M. S.

    2014-12-01

    In this article we evaluate state-resolved charge exchange cross sections for Be{}4+, {{{B}}}5+, {{{C}}}6+, {{{N}}}7+, and {{{O}}}8+ projectiles colliding with atomic hydrogen employing two different methods: the classical trajectory Monte Carlo and the eikonal impulse approximations. These cross sections are used to extend previously derived scaling laws for n-, nl-, and nlm-distributions to highly excited final levels with 4≤slant n≤slant 9, covering energies in the range 50-2000 {{keV}}/ amu. Present total and partial capture cross sections are in agreement with available experimental and theoretical data for these collision systems. Besides, the proposed scaling rules are also verified by other theories, becoming a useful instrument for plasma research.

  15. QED calculation of transition probabilities in two-electron ions

    NASA Astrophysics Data System (ADS)

    Andreev, Oleg Yu.; Labzowsky, Leonti N.; Plunien, Günter

    2009-03-01

    An accurate QED calculation of transition probabilities for the low-lying two-electron configurations of multicharged ions is presented. The calculation is performed for the nondegenerate states (1s2s)S31 , (1s2p3/2)P32 ( M1 and M2 transitions, respectively) and for the quasidegenerate states (1s2p)P11 , (1s2p)P31 ( E1 transitions) decaying to the ground state (1s1s)S10 . Two-electron ions with nuclear-charge numbers Z=10-92 are considered. The line profile approach is employed for the description of the process in multicharged ions within the framework of QED.

  16. Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source.

    PubMed

    Nakamura, T; Wada, H; Asaji, T; Furuse, M

    2016-02-01

    Herein, we conduct a fundamental study to improve the generation efficiency of a multi-charged ion source using argon. A magnetic field of our electron cyclotron resonance ion source is composed of a permanent magnet and a solenoid coil. Thereby, the axial magnetic field in the chamber can be tuned. Using the solenoid coil, we varied the magnetic field strength in the plasma chamber and measured the ion beam current extracted at the electrode. We observed an approximately three times increase in the Ar(4+) ion beam current when the magnetic field on the extractor-electrode side of the chamber was weakened. From our results, we can confirm that the multi-charged ion beam current changes depending on magnetic field intensity in the plasma chamber. PMID:26931955

  17. Status of Plasma Spectroscopy Method for CNS Hyper-ECR Ion Source at RIKEN

    NASA Astrophysics Data System (ADS)

    Muto, Hideshi; Ohshiro, Yukimitsu; Yamaka, Shoichi; Watanabe, Shin-ichi; Oyaizu, Michihiro; Kubono, Shigeru; Yamaguchi, Hidetoshi; Kase, Masayuki; Hattori, Toshiyuki; Shimoura, Susumu

    The optical line spectra of multi-charged gaseous and metal ion beams from ECR plasma have been observed using a grating monochromator with photomultiplier. This new method simplifies the observation of the targeted ion species in the plasma during beam tuning. In this paper we describe present condition of the Hyper-ECR ion source tuning with this plasma spectroscopy method. This data is important because separation of ion species of the same charge to mass ratio with an electromagnetic mass analyzer is almost impossible.

  18. Effet de l'énergie du faisceau d'ions servant à l'assistance du dépôt de matériaux organiques utilisés pour réaliser des diodes électroluminescentes

    NASA Astrophysics Data System (ADS)

    Antony, R.; Moliton, A.; Ratier, B.

    1998-06-01

    Light emitting diode based on the structure ITO/Alq3/Ca-Al lead to enhanced quantum efficiency when the Alq3 active layer is obtained by IBAD (Ion Beam Assisted Deposition): with Iodine ions, the optimization (quantum efficiency multiplied by a factor10) is obtained for an ion energy equal to 100eV. La réalisation de diodes électroluminescentes basées sur la structure ITO/Alq3/Ca-Al conduit à des performances améliorées lorsque le dépôt de la couche active Alq3 est effectué avec l'assistance d'un faisceau d'ions; l'optimisation (rendement quantique interne accru d'un ordre de grandeur) correspond à des ions Iode d'énergie 100eV.

  19. Design study of low-energy beam transport for multi-charge beams at RAON

    NASA Astrophysics Data System (ADS)

    Bahng, Jungbae; Qiang, Ji; Kim, Eun-San

    2015-12-01

    The Rare isotope Accelerator Of Newness (RAON) at the Rare Isotope Science Project (RISP) is being designed to simultaneously accelerate beams with multiple charge states. It includes a driver superconducting (SC) linac for producing 200 MeV/u and 400 kW continuous wave (CW) heavy ion beams from protons to uranium. The RAON consists of a few electron cyclotron resonance ion sources, a low-energy beam transport (LEBT) system, a CW 81.25 MHz, 500 keV/u radio frequency quadrupole (RFQ) accelerator, a medium-energy beam transport system, the SC linac, and a charge-stripper system. The LEBT system for the RISP accelerator facility consists of a high-voltage platform, two 90° dipoles, a multi-harmonic buncher (MHB), solenoids, electrostatic quadrupoles, a velocity equalizer, and a diagnostic system. The ECR ion sources are located on a high-voltage platform to reach an initial beam energy of 10 keV/u. After extraction, the ion beam is transported through the LEBT system to the RFQ accelerator. The generated charge states are selected by an achromatic bending system and then bunched by the MHB in the LEBT system. The MHB is used to achieve a small longitudinal emittance in the RFQ by generating a sawtooth wave with three harmonics. In this paper, we present the results and issues of the beam dynamics of the LEBT system.

  20. Search for heavy long-lived multi-charged particles in pp collisions at √s = 8  TeV using the ATLAS detector

    DOE PAGES

    None

    2015-08-08

    A search for heavy long-lived multi-charged particles is performed using the ATLAS detector at the LHC. Data collected in 2012 at √s = 8 TeV from pp collisions corresponding to an integrated luminosity of 20.3 fb-1 are examined. Particles producing anomalously high ionisation, consistent with long-lived massive particles with electric charges from |q| = 2e to |q| = 6e are searched for. No signal candidate events are observed, and 95 % confidence level cross-section upper limits are interpreted as lower mass limits for a Drell–Yan production model. The mass limits range between 660 and 785 GeV.

  1. Des Moines.

    ERIC Educational Resources Information Center

    Gore, Deborah, Ed.

    1988-01-01

    This document, intended for elementary students, contains articles and activities designed to acquaint young people with the history of Des Moines, Iowa. The articles are short, and new or difficult words are highlighted and defined for young readers. "The Raccoon River Indian Agency" discusses the archeological exploration of the indian…

  2. Quightness: A proposed figure of merit for sources of low-energy, high-charge-state ions

    NASA Astrophysics Data System (ADS)

    Schmieder, Robert W.

    1990-03-01

    A variety of ion sources, including the EBIS and ECRIS, are distinguished by their ability to produce low-energy ions of very high charge state. It would be useful to have some figure of merit that is particularly sensitive to this performance. I propose here such a quantity, called ``Quightness,'' which is related to brightness but which enhances the contrast between sources supplying multicharged ions of low energy. The rationale for introducing this quantity, its etymology and relationship to other figures of merit, and some representative values are presented.

  3. Mono-energetic ions emission by nanosecond laser solid target irradiation

    NASA Astrophysics Data System (ADS)

    Muoio, A.; Tudisco, S.; Altana, C.; Lanzalone, G.; Mascali, D.; Cirrone, G. A. P.; Schillaci, F.; Trifirò, A.

    2016-09-01

    An experimental campaign aiming to investigate the acceleration mechanisms through laser-matter interaction in nanosecond domain has been carried out at the LENS (Laser Energy for Nuclear Science) laboratory of INFN-LNS, Catania. Pure Al targets were irradiated by 6 ns laser pulses at different pumping energies, up to 2 J. Advanced diagnostics tools were used to characterize the plasma plume and ion production. We show the preliminary results of this experimental campaign, and especially the ones showing the production of multicharged ions having very narrow energy spreads.

  4. Electron-impact ionization of the Se2+ and Se3+ atomic ions

    NASA Astrophysics Data System (ADS)

    Loch, S. D.; Pindzola, M. S.

    2016-05-01

    Semi-relativistic configuration-average distorted-wave (CADW) calculations are made for the electron-impact ionization of the Se2+ and Se3+ atomic ions. The CADW calculations are found to be in reasonable agreement with recent measurements made at the Multicharged Ion Research Facility at the University of Nevada in Reno. The CADW calculations for configurations near ionization thresholds are checked against level to level distorted-wave (LLDW) calculations. Work supported in part by Grants from NASA, NSF, and DOE.

  5. Kinetic and Potential Sputtering of Lunar Regolith: Contribution of Solar-Wind Heavy Ions

    NASA Technical Reports Server (NTRS)

    Meyer, F. W.; Harris, P. R.; Meyer, H. M., III; Hijiazi, H.; Barghouty, A. F.

    2013-01-01

    Sputtering of lunar regolith by protons as well as solar-wind heavy ions is considered. From preliminary measurements of H+, Ar+1, Ar+6 and Ar+9 ion sputtering of JSC-1A AGGL lunar regolith simulant at solar wind velocities, and TRIM simulations of kinetic sputtering yields, the relative contributions of kinetic and potential sputtering contributions are estimated. An 80-fold enhancement of oxygen sputtering by Ar+ over same-velocity H+, and an additional x2 increase for Ar+9 over same-velocity Ar+ was measured. This enhancement persisted to the maximum fluences investigated is approximately 1016/cm (exp2). Modeling studies including the enhanced oxygen ejection by potential sputtering due to the minority heavy ion multicharged ion solar wind component, and the kinetic sputtering contribution of all solar wind constituents, as determined from TRIM sputtering simulations, indicate an overall 35% reduction of near-surface oxygen abundance. XPS analyses of simulant samples exposed to singly and multicharged Ar ions show the characteristic signature of reduced (metallic) Fe, consistent with the preferential ejection of oxygen atoms that can occur in potential sputtering of some metal oxides.

  6. Search for heavy long-lived multi-charged particles in pp collisions at $$\\sqrt{s}=8$$ s = 8  TeV using the ATLAS detector

    SciTech Connect

    Aad, G.; Abbott, B.; Abdallah, J.; Abdinov, O.; Aben, R.; Abolins, M.; AbouZeid, O. S.; Abramowicz, H.; Abreu, H.; Abreu, R.; Abulaiti, Y.; Acharya, B. S.; Adamczyk, L.; Adams, D. L.; Adelman, J.; Adomeit, S.; Adye, T.; Affolder, A. A.; Agatonovic-Jovin, T.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akerstedt, H.; Åkesson, T. P. A.; Akimoto, G.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albrand, S.; Alconada Verzini, M. J.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Alimonti, G.; Alio, L.; Alison, J.; Alkire, S. P.; Allbrooke, B. M. M.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Altheimer, A.; Alvarez Gonzalez, B.; Álvarez Piqueras, D.; Alviggi, M. G.; Amako, K.; Amaral Coutinho, Y.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amorim, A.; Amoroso, S.; Amram, N.; Amundsen, G.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, G.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Anger, P.; Angerami, A.; Anghinolfi, F.; Anisenkov, A. V.; Anjos, N.; Annovi, A.; Antonelli, M.; Antonov, A.; Antos, J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Arabidze, G.; Arai, Y.; Araque, J. P.; Arce, A. T. H.; Arduh, F. A.; Arguin, J-F.; Argyropoulos, S.; Arik, M.; Armbruster, A. J.; Arnaez, O.; Arnal, V.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Asai, S.; Asbah, N.; Ashkenazi, A.; Åsman, B.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkinson, M.; Atlay, N. B.; Auerbach, B.; Augsten, K.; Aurousseau, M.; Avolio, G.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baak, M. A.; Baas, A. E.; Bacci, C.; Bachacou, H.; Bachas, K.; Backes, M.; Backhaus, M.; Bagiacchi, P.; Bagnaia, P.; Bai, Y.; Bain, T.; Baines, J. T.; Baker, O. K.; Balek, P.; Balestri, T.; Balli, F.; Banas, E.; Banerjee, Sw.; Bannoura, A. A. E.; Bansil, H. S.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisonzi, M.; Barklow, T.; Barlow, N.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Basye, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Beccherle, R.; Bechtle, P.; Beck, H. P.; Becker, K.; Becker, M.; Becker, S.; Beckingham, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bee, C. P.; Beemster, L. J.; Beermann, T. A.; Begel, M.; Behr, J. K.; Belanger-Champagne, C.; Bell, W. H.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Beltramello, O.; Benary, O.; Benchekroun, D.; Bender, M.; Bendtz, K.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez Garcia, J. A.; Benjamin, D. P.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Berghaus, F.; Beringer, J.; Bernard, C.; Bernard, N. R.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertolucci, F.; Bertsche, C.; Bertsche, D.; Besana, M. I.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Betancourt, C.; Bethke, S.; Bevan, A. J.; Bhimji, W.; Bianchi, R. M.; Bianchini, L.; Bianco, M.; Biebel, O.; Bieniek, S. P.; Biglietti, M.; Bilbao De Mendizabal, J.; Bilokon, H.; Bindi, M.; Binet, S.; Bingul, A.; Bini, C.; Black, C. W.; Black, J. E.; Black, K. M.; Blackburn, D.; Blair, R. E.; Blanchard, J. -B.; Blanco, J. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blum, W.; Blumenschein, U.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boehler, M.; Bogaerts, J. A.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bold, T.; Boldea, V.; Boldyrev, A. S.; Bomben, M.; Bona, M.; Boonekamp, M.; Borisov, A.; Borissov, G.; Borroni, S.; Bortfeldt, J.; Bortolotto, V.; Bos, K.; Boscherini, D.; Bosman, M.; Boudreau, J.; Bouffard, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Bousson, N.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bozic, I.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J. E.; Braun, H. M.; Brazzale, S. F.; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Bristow, K.; Bristow, T. M.; Britton, D.; Britzger, D.; Brochu, F. M.; Brock, I.; Brock, R.; Bronner, J.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brosamer, J.; Brost, E.; Brown, J.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruneliere, R.; Bruni, A.; Bruni, G.; Bruschi, M.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Buda, S. I.; Budagov, I. A.; Buehrer, F.; Bugge, L.; Bugge, M. K.; Bulekov, O.; Bullock, D.

    2015-08-01

    A search for heavy long-lived multi-charged particles is performed using the ATLAS detector at the LHC. Data collected in 2012 at √s=8 TeV TeV from pp collisions corresponding to an integrated luminosity of 20.3 fb-1 are examined. Particles producing anomalously high ionisation, consistent with long-lived massive particles with electric charges from |q|=2e to |q|=6e are searched for. No signal candidate events are observed, and 95 % confidence level cross-section upper limits are interpreted as lower mass limits for a Drell–Yan production model. The mass limits range between 660 and 785 GeV.

  7. Search for heavy long-lived multi-charged particles in pp collisions at √s = 8  TeV using the ATLAS detector

    SciTech Connect

    2015-08-08

    A search for heavy long-lived multi-charged particles is performed using the ATLAS detector at the LHC. Data collected in 2012 at √s = 8 TeV from pp collisions corresponding to an integrated luminosity of 20.3 fb-1 are examined. Particles producing anomalously high ionisation, consistent with long-lived massive particles with electric charges from |q| = 2e to |q| = 6e are searched for. No signal candidate events are observed, and 95 % confidence level cross-section upper limits are interpreted as lower mass limits for a Drell–Yan production model. The mass limits range between 660 and 785 GeV.

  8. Constantes de stabilité de complexes organo-minéraux. Interactions des ions plombeux avec les composés organiques hydrosolubles des eaux gravitaires de podzol

    NASA Astrophysics Data System (ADS)

    Bizri, Y.; Cromer, M.; Scharff, J. P.; Guillet, B.; Rouiller, J.

    1984-02-01

    The complexation of lead(II) ions by water-soluble soil organic matter as ligand (recovered by percolating water through a A2 horizon of a podzolic soil) has been studied by potentiometric methods at 25°C in 0.1 M NaClO 4 medium. The total acidity of these solutions was resolved into strong, weak and very weak acidity. During the alkali titration, the dissociation of humic samples was characterized by an α coefficient that may be determined according to a procedure derived from Irving-Rossotti's method. The so-called Henderson-Hasselbalch equation was used to obtain pK A values for each of the two weak acidities ( pKA = 4.80 (COOH) and pKA = 8.85 (OH)). For the determination of stability constants of metal-humate complexes (HA) in the acidic range, three methods have been investigated: - an approach using only pH measurements. - direct estimation of the free metal ion concentrations from ISE determinations. - application of Marinsky's method accounting for complications arising from the electric field at the surface of the polyelectrolyte which determines the effective concentration [A]. In these experiments typical values used for total lead(II) ion concentrations and total ligand concentrations are respectively in the range 4.10 -5 M to 4.10 -4 M and 0,33 to 0,57 meq·1 -1. All results agree with the existence of mono and bis-complexes PbA and PbA 2 with stability constants (protometric determinations): logK1 = 4.2 and logK2 = 3.7. The values obtained by direct estimation of free lead(II) concentration are slightly lower. An increase in stability constants was observed with increase in pH and also with decrease in total metal ion concentration (at constant pH). Ligand conformational properties are expected to be of great importance in the complexation phenomena.

  9. Effets des electrons secondaires sur l'ADN

    NASA Astrophysics Data System (ADS)

    Boudaiffa, Badia

    Les interactions des electrons de basse energie (EBE) representent un element important en sciences des radiations, particulierement, les sequences se produisant immediatement apres l'interaction de la radiation ionisante avec le milieu biologique. Il est bien connu que lorsque ces radiations deposent leur energie dans la cellule, elles produisent un grand nombre d'electrons secondaires (4 x 104/MeV), qui sont crees le long de la trace avec des energies cinetiques initiales bien inferieures a 20 eV. Cependant, il n'y a jamais eu de mesures directes demontrant l'interaction de ces electrons de tres basse energie avec l'ADN, du principalement aux difficultes experimentales imposees par la complexite du milieu biologique. Dans notre laboratoire, les dernieres annees ont ete consacrees a l'etude des phenomenes fondamentaux induits par impact des EBE sur differentes molecules simples (e.g., N2, CO, O2, H2O, NO, C2H 4, C6H6, C2H12) et quelques molecules complexes dans leur phase solide. D'autres travaux effectues recemment sur des bases de l'ADN et des oligonucleotides ont montre que les EBE produisent des bris moleculaires sur les biomolecules. Ces travaux nous ont permis d'elaborer des techniques pour mettre en evidence et comprendre les interactions fondamentales des EBE avec des molecules d'interet biologique, afin d'atteindre notre objectif majeur d'etudier l'effet direct de ces particules sur la molecule d'ADN. Les techniques de sciences des surfaces developpees et utilisees dans les etudes precitees peuvent etre etendues et combinees avec des methodes classiques de biologie pour etudier les dommages de l'ADN induits par l'impact des EBE. Nos experiences ont montre l'efficacite des electrons de 3--20 eV a induire des coupures simple et double brins dans l'ADN. Pour des energies inferieures a 15 eV, ces coupures sont induites par la localisation temporaire d'un electron sur une unite moleculaire de l'ADN, ce qui engendre la formation d'un ion negatif transitoire

  10. Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source

    NASA Astrophysics Data System (ADS)

    Shin, Chang Seouk; Lee, Byoung-Seob; Choi, Seyong; Yoon, Jang-Hee; Kim, Hyun Gyu; Ok, Jung-Woo; Park, Jin Yong; Kim, Seong Jun; Bahng, Jungbae; Hong, Jonggi; Lee, Seung Wook; Won, Mi-Sook

    2016-02-01

    The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1-10 mm2. The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.

  11. Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source.

    PubMed

    Shin, Chang Seouk; Lee, Byoung-Seob; Choi, Seyong; Yoon, Jang-Hee; Kim, Hyun Gyu; Ok, Jung-Woo; Park, Jin Yong; Kim, Seong Jun; Bahng, Jungbae; Hong, Jonggi; Lee, Seung Wook; Won, Mi-Sook

    2016-02-01

    The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1-10 mm(2). The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.

  12. Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source.

    PubMed

    Shin, Chang Seouk; Lee, Byoung-Seob; Choi, Seyong; Yoon, Jang-Hee; Kim, Hyun Gyu; Ok, Jung-Woo; Park, Jin Yong; Kim, Seong Jun; Bahng, Jungbae; Hong, Jonggi; Lee, Seung Wook; Won, Mi-Sook

    2016-02-01

    The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1-10 mm(2). The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research. PMID:26931931

  13. Development of an ion beam analyzing system for the KBSI heavy-ion accelerator

    NASA Astrophysics Data System (ADS)

    Bahng, Jungbae; Hong, Jonggi; Park, Jin Yong; Kim, Seong Jun; Ok, Jung-Woo; Choi, Seyong; Shin, Chang Seouk; Yoon, Jang-Hee; Won, Mi-Sook; Lee, Byoung-Seob; Kim, Eun-San

    2016-02-01

    The Korea Basic Science Institute (KBSI) has been developing a heavy ion accelerator system to accelerate high current, multi-charge state ions produced by a 28 GHz superconducting electron cyclotron ion source. A beam analyzing system as a part of the low energy beam transport apparatus was developed to select charged particles with desirable charge states from the ion beams. The desired species of ion, which is generated and extracted from the ECR ion source including various ion particles, can be selected by 90° dipole electromagnet. Due to the non-symmetrical structure in the coil as well as the non-linear permeability of the yoke material coil, a three dimensional analysis was carried out to confirm the design parameters. In this paper, we present the experimental results obtained as result of an analysis of KBSI accelerator. The effectiveness of beam selection was confirmed during the test of the analyzing system by injecting an ion beam from an ECR ion source.

  14. Dielectric Theory of the Electronic Energy Loss of Heavy Ions in Solids (German Title: Dielektrische Theorie des elektronischen Energieverlustes schwerer Ionen in Festkörpern)

    NASA Astrophysics Data System (ADS)

    Mathar, Richard J.

    1995-05-01

    The present work deals with the effective charge theory of the electronic energy loss in homogeneous solids from the point of view of target and ion models: Chapter 1 is an introduction and contains a review of the Lindhard-Winther-Theory. Chapter 2 deals with the stopping of ions in the homogeneous electron gas. A calculation of the linear susceptibility of interacting target electrons is presented in the lowest order, i.e., the next order beyond the Random Phase Approximation. Complementary to a calculation known from the literature, more compact notations of integrals are given for the real part, which allow to bypass a Kramers-Kronig analysis. When applied to the energy loss of punctiform ions, the noticeable increase of the stopping power compared with the Random Phase Approximation at low velocities that is known from density functional calculations is confirmed. At high velocities, which are treated by time-independent density functional calculations solely via extrapolations, a correction of the opposite sign is found, which can be understood on the basis of a sum rule of the polarization. Chapter 3 first recalls the Brandt-Kitagawa-Theory of the electronic energy loss of heavy ions and the description by Ziegler et al. that builds on it. It is pointed out, in how far the true charges which they derived from effective charges (as defined by the electronic energy loss) are uncertain due to model assumptions and approximations. An energy-stability criterion of the ionization degree as a function of the ion velocity - the most essential ion parameter - is introduced, which is known, but has hitherto been regarded as inferior. A couple of reasons are discussed that demonstrate the superiority of its way of explaining ionization degrees relative to the competing velocity criterion that has been used up to know. A generalization in terms of an adaptation of the electro-chemical potential of the electrons bound to the ion to the potential of the electrons in the

  15. Development of a surface ionization source for the production of radioactive alkali ion beams in SPIRAL

    NASA Astrophysics Data System (ADS)

    Eléon, C.; Jardin, P.; Gaubert, G.; Saint-Laurent, M.-G.; Alcántara-Núñez, J.; Alvès Condé, R.; Barué, C.; Boilley, D.; Cornell, J.; Delahaye, P.; Dubois, M.; Jacquot, B.; Leherissier, P.; Leroy, R.; Lhersonneau, G.; Marie-Jeanne, M.; Maunoury, L.; Pacquet, J. Y.; Pellemoine, F.; Pierret, C.; Thomas, J. C.; Villari, A. C. C.

    2008-10-01

    In the framework of the production of radioactive alkali ion beams by the isotope separation on-line (ISOL) method in SPIRAL I, a surface ionization source has been developed at GANIL to produce singly-charged ions of Li, Na and K. This new source has been designed to work in the hostile environment whilst having a long lifetime. This new system of production has two ohmic heating components: the first for the target oven and the second for the ionizer. The latter, being in carbon, offers high reliability and competitive ionization efficiency. This surface ionization source has been tested on-line using a 48Ca primary beam at 60.3 A MeV with an intensity of 0.14 pA. The ionization efficiencies obtained for Li, Na and K are significantly better than the theoretical values of the ionization probability per contact. The enhanced efficiency, due to the polarization of the ionizer, is shown to be very important also for short-lived isotopes. In the future, this source will be associated with the multicharged electron-cyclotron-resonance (ECR) ion source NANOGAN III for production of multicharged alkali ions in SPIRAL. The preliminary tests of the set up are also presented in this contribution.

  16. Etude des defauts microscopiques et des proprietes optiques, electroniques et magnetiques du compose neodyme cerium oxyde de cuivre

    NASA Astrophysics Data System (ADS)

    Richard, Pierre

    La presente these, qui combine des mesures de diffusion Raman, de transmission infrarouge, de conductivite hyperfrequence et d'interferometrie ultrasonore sur les composes Nd 2-xCexCuO 4, traite des defauts d'oxygene, ainsi que des proprietes optiques, electroniques et magnetiques de ces materiaux. Les resultats experimentaux obtenus sont correles avec plusieurs donnees experimentales disponibles dans la litterature. D'abord, la caracterisation des modes Raman et des niveaux d'energie de champ cristallin de l'ion Nd3+ au moyen de techniques optiques, en fonction du dopage en cerium et du contenu en oxygene, permettent de conclure a la presence de defauts lies a une non-stoechiometrie en oxygene dans ces composes. En effet, des excitations de champ cristallin assignees a des ions Nd3+ en sites irreguliers sont observees, en plus des bandes d'absorption associees aux ions Nd3+ en site regulier, dans les spectres correspondant aux multiplets 4I11/2, 4I13/2 et 4I 15/2 de l'ion Nd3+. Les resultats experimentaux indiquent que, contrairement a la croyance largement repandue, les oxygenes apicaux, bien que presents dans les echantillons dopes, ne sont pas enleves lors du processus de reduction des echantillons necessaire pour faire apparaitre la supraconductivite dans cette famille de cuprates. Au contraire, des lacunes d'oxygene, dont le type varie en fonction du dopage, sont creees lors de ce processus. En particulier, il est montre dans ce travail que la reduction des echantillons dopes de maniere optimale conduit a la creation de lacunes d'oxygene dans les plans CuO2. Les consequences de telles lacunes sont largement discutees. En outre, il est suggere que de telles lacunes sont responsables de la perte de l'ordre antiferromagnetique a longue portee des ions Cu2+. Finalement, l'interaction d'echange anisotrope Nd3+-Cu 2+ dans le compose nondope est caracterisee au moyen de la transmission infrarouge sous champ magnetique. L'eclatement des doublets de Kramers mesure

  17. Development of Electron Cyclotron Resonance Ion Source for Synthesis of Endohedral Metallofullerenes

    SciTech Connect

    Tanaka, K.; Muramatsu, M.; Uchida, T.; Hanajiri, T.; Yoshida, Y.; Biri, S.; Kitagawa, A.; Kato, Y.

    2008-11-03

    A new electron cyclotron resonance ion source (ECRIS) has been constructed for synthesis of endohedral metallofullerenes. The main purpose of the ion source is to produce new biological and medical materials. The design is based on ECRIS for production of multicharged ion beams with a traditional minimum-B magnetic field. An 8-10 GHz traveling wave tube (TWT) amplifier and a 2.45 GHz magnetron have been applied as microwave sources. Fullerene and metal vapor are introduced with a filament heating micro-oven and an induction heating oven, respectively. In preliminary ion-extraction test, Ar{sup +} is 54 {mu}A. Many broken fullerenes such as C{sub 58} and C{sub 56} are observed in fullerene ion beams.

  18. Development of Electron Cyclotron Resonance Ion Source for Synthesis of Endohedral Metallofullerenes

    NASA Astrophysics Data System (ADS)

    Tanaka, K.; Muramatsu, M.; Uchida, T.; Biri, S.; Asaji, T.; Shima, K.; Hanajiri, T.; Kitagawa, A.; Kato, Y.; Yoshida, Y.

    2008-11-01

    A new electron cyclotron resonance ion source (ECRIS) has been constructed for synthesis of endohedral metallofullerenes. The main purpose of the ion source is to produce new biological and medical materials. The design is based on ECRIS for production of multicharged ion beams with a traditional minimum-B magnetic field. An 8-10 GHz traveling wave tube (TWT) amplifier and a 2.45 GHz magnetron have been applied as microwave sources. Fullerene and metal vapor are introduced with a filament heating micro-oven and an induction heating oven, respectively. In preliminary ion-extraction test, Ar+ is 54 μA. Many broken fullerenes such as C58 and C56 are observed in fullerene ion beams.

  19. Etude spectroscopique des ions cuivre (II) en coordinence tétraédrique dans les silicates synthétiques de type milarite

    NASA Astrophysics Data System (ADS)

    Choisnet, Jacques; Cornet, Daniel; Hemidy, Jean-François; Nguyen, Ninh; Dat, Yves

    1981-11-01

    ESR spectra of copper-containing silicates Na 2Mg 5- xCu xSi 12O 30 with a milarite structure have been recorded at two frequencies (X band and Q band) and at several temperatures in the range 298-77K. For x less than 0.5 the well-resolved powder spectrum is characteristic of tetrahedral copper ions in orthorhombic symmetry with gzz = 2.517; gxx = 2.135; gyy = 2.091. The hyperfine structure is completely resolved at 77K ( Azz = 45.9 × 10 -4cm -1; Ayy = 23.0 × 10 -4cm -1; Axx = 41.0 × 10 -4cm -1). The ESR parameters may be interpreted in terms of an admixture of 4 pz wavefunction into the 3 dxy ground state. The results are in good agreement with diffuse reflectance spectra and crystal field calculations.

  20. Temporal behavior of unresolved transition array emission in water window soft x-ray spectral region from multiply charged ions

    NASA Astrophysics Data System (ADS)

    Dinh, Thanh-Hung; Suzuki, Yuhei; Arai, Goki; Li, Bowen; Dunne, Padraig; O'Sullivan, Gerry; Fujioka, Shinsuke; Hasegawa, Noboru; Kawachi, Tetsuya; Nishikino, Masaharu; Higashiguchi, Takeshi

    2015-09-01

    We have characterized the spectral structure and the temporal history of the laser-produced high-Z multi-charged ion plasmas for the efficient water window soft x-ray sources. Strong unresolved transition array emission was observed due to 4d-4f and 4f-5g transitions from Au, Pb, and Bi plasmas in the 280-700 eV photon energy region. The temporal behavior of the emission was essentially similar of that of the laser pulse with a slight delay between different transitions. These results provide feedback for accurate modeling of the atomic processes with the radiative hydrodynamic simulations.

  1. Temporal behavior of unresolved transition array emission in water window soft x-ray spectral region from multiply charged ions

    SciTech Connect

    Dinh, Thanh-Hung Suzuki, Yuhei; Arai, Goki; Higashiguchi, Takeshi; Li, Bowen; Dunne, Padraig; O'Sullivan, Gerry; Fujioka, Shinsuke; Hasegawa, Noboru; Kawachi, Tetsuya; Nishikino, Masaharu

    2015-09-21

    We have characterized the spectral structure and the temporal history of the laser-produced high-Z multi-charged ion plasmas for the efficient water window soft x-ray sources. Strong unresolved transition array emission was observed due to 4d–4f and 4f–5g transitions from Au, Pb, and Bi plasmas in the 280–700 eV photon energy region. The temporal behavior of the emission was essentially similar of that of the laser pulse with a slight delay between different transitions. These results provide feedback for accurate modeling of the atomic processes with the radiative hydrodynamic simulations.

  2. Charge state distributions from highly charged ions channeled at a metal surface

    SciTech Connect

    Folkerts, L.; Meyer, F.W.; Schippers, S. |

    1994-06-01

    The vast majority of the experimental work in the field of multicharged ion-surface interactions, to date, has focused on x-ray and particularly on electron emission. These experiments include measurements of the total electron yield, the emission statistics of the electrons, and, most of all, the electron energy distributions. So far, little attention has been paid to the fate of the multicharged projectile ions after the scattering. To our knowledge, the only measurement of the charge state distribution of the scattered ions is the pioneering experiment of de Zwart et al., who measured the total yield of scattered 1+, 2+, and 3+ ions as a function of the primary charge state q (q = 1--11) for 20 key Ne, Ar, and Kr ions after reflection from a polycrystalline tungsten target. Their main finding is the sudden onset of scattered 3+ ions when inner-shell vacancies are present in the primary particles. This suggests that a certain fraction of the inner-shell vacancies survives the entire collision event, and decays via autoionization on the outgoing path. Since the projectiles scattered in the neutral charge state could not be detected in the experiment of de Zwart et al., they were not able to provide absolute charge state fractions. In our present experiment, we focus on the scattered projectiles, measuring both the final charge state and the total scattering angle with a single 2D position sensitive detector (PSD). This method gives us the number of positive, as well as neutral and negative, scattered ions, thus allowing us to extract absolute charge state fractions. Using a well-prepared single Au(110) crystal and a grazing incidence geometry, we were able to observe surface channeling along the [001] channels.

  3. (The physics of highly charged ions)

    SciTech Connect

    Phaneuf, R.A.

    1990-10-12

    The Fifth International Conference on the Physics of Highly Charged Ions drew more than 200 participants, providing an excellent overview of this growing field. Important technical developments and experimental results in electron-ion collisions were reported. The merging of fast ion beams from accelerators or storage rings with advanced high-intensity electron-beam targets has yielded data of unprecedented quality on radiative and dielectronic recombination, providing stringent tests of theory. Long-awaited technical innovations in electron-impact excitation measurements were also reported. The level of activity in multicharged ion-surface interactions has increased. More sophisticated experimental studies of the neutralization process have shown the inadequacy of previously accepted mechanisms, and theoretical activity in this area is just being initiated. The IAEA meetings addressed atomic and molecular data needs for fusion research, with ITER providing a key focus. Such data are especially critical to modeling and diagnostics of the edge plasma. The ALADDIN data base system has been universally accepted and has streamlined the exchange of numerical data among data centers and the fusion community. The IAEA continues to play a pivotal role in the identification of data needs, and in the coordination of data compilation and research activities for fusion applications.

  4. Contribution aux Methodes Analytiques des Substances a L'aide de Faisceaux de Particules Chargees

    NASA Astrophysics Data System (ADS)

    Saidi, Abdelmajid

    Nous avons vu les possibilites d'analyse par particules chargees des aerosols recueillis sur des filtres de type MILLIPORE. La meme technique a ete utilisee pour des filtres ayant servi a la filtration de l'eau du fleuve Saint-laurent. Deux techniques ont ete utilisees: (1) FAST (Forward Alpha Scattering Technique): pour analyser l'hydrogene, le carbone, l'oxygene et puis l'azote. Des alpha de 12 MeV ont ete utilises. (2) PIXE (Particle Induced X-ray Emission): pour analyser les elements moyens et lourds, dans ce cas des protons de 3 MeV ainsi que des ions d'argon de 1 et 1.6 MeV ont ete utilises. Les etudes ont montre que sous vide, la majorite des problemes proviennent des dommages causes par l'echauffement du a l'impact du faisceau sur le filtre. L'analyse quantitative par l'intermediaire du faisceau extrait peut presenter des difficultes en ce qui concerne les elements legers pour lesquels l'absorption des rayonnements caracteristiques dans l'atmosphere externe est importante. Les ions lourds se pretent mal aux analyses des aerosols du fait de leur limite de sensibilite. L'analyse directe de liquides par des protons est particulierement interessante puisqu'elle ne necessite aucune preparation prealable des echantillons. A cet effet, un programme de calcul de concentration des elements dans la solution a analyser a ete mis au point. Nous avons determine la limite de sensibilite de la methode PIXE pour les cibles minces (filtre) et pour le cas ou la matrice est de l'eau. Enfin, la technique FAST peut etre un complement de la technique PIXE.

  5. Interference of radiating states and ion dynamics in spectral line broadening

    NASA Astrophysics Data System (ADS)

    Kosarev, I. N.; Stehlé, C.; Feautrier, N.; Demura, A. V.; Lisitsa, V. S.

    1997-01-01

    The influence of the plasma coupling between the populations and the coherences on the lineshape is investigated. Ion dynamics is taken into account. The present research is performed within the atomic density matrix formalism. Ion microfield dynamics is simulated by the kangaroo - Poisson stochastic process (model microfield method). Numerical calculations of both lifetimes of radiating states and lineshapes are performed for the spectral doublet (1s - 2s)0953-4075/30/2/016/img6 - (1s - 4p)0953-4075/30/2/016/img7, (1s - 2)0953-4075/30/2/016/img6 - (1s - 4d)0953-4075/30/2/016/img9 of helium-like multicharged ions in hot dense plasmas. It is found that the ion microfield essentially influences the difference of populations of radiating 0953-4075/30/2/016/img10 states. Calculation of the lineshape of the doublet (1s - 2p)0953-4075/30/2/016/img11 - (1s - 4d)0953-4075/30/2/016/img12, (1s - 2p)0953-4075/30/2/016/img11 - (1s - 4f)0953-4075/30/2/016/img14 of neutral helium at astrophysical plasma conditions is also performed. The contribution of nonlinear interference effects (NIEF) in both allowed and forbidden components is calculated at various plasma conditions and a comparison with binary adiabatic theory is made. The results demonstrate that it is essential to take account of NIEF in the calculation of lineshapes of multicharged ions, but not essential in the case of neutral helium.

  6. Ion Beam Analysis applied to laser-generated plasmas

    NASA Astrophysics Data System (ADS)

    Cutroneo, M.; Macková, A.; Havranek, V.; Malinsky, P.; Torrisi, L.; Kormunda, M.; Barchuk, M.; Ullschmied, J.; Dudzak, R.

    2016-04-01

    This paper presents the research activity on Ion Beam Analysis methods performed at Tandetron Laboratory (LT) of the Institute of Nuclear Physics AS CR, Rez, Czech Republic. Recently, many groups are paying attention to implantation by laser generated plasma. This process allows to insert a controllable amount of energetic ions into the surface layers of different materials modifying the physical and chemical properties of the surface material. Different substrates are implanted by accelerated ions from plasma through terawatt iodine laser, at nominal intensity of 1015 W/cm2, at the PALS Research Infrastructure AS CR, in the Czech Republic. This regime of the laser matter interaction generates, multi-MeV proton beams, and multi-charged ions that are tightly confined in time (hundreds ps) and space (source radius of a few microns). These ion beams have a much lower transverse temperature, a much shorter duration and a much higher current than those obtainable from conventional accelerators. The implementation of protons and ions acceleration driven by ultra-short high intensity lasers is exhibited by adopting suitable irradiation conditions as well as tailored targets. An overview of implanted targets and their morphological and structural characterizations is presented and discussed.

  7. Des ballons pour demain

    NASA Astrophysics Data System (ADS)

    Régipa, R.

    A partir d'une théorie sur la détermination des formes et des contraintes globales d'un ballon de révolution, ou s'en rapprochant, une nouvelle famille de ballons a été définie. Les ballons actuels, dits de ``forme naturelle'', sont calculés en général pour une tension circonférencielle nulle. Ainsi, pour une mission donnée, la tension longitudinale et la forme de l'enveloppe sont strictement imposées. Les ballons de la nouvelle génération sont globalement cylindriques et leurs pôles sont réunis par un câble axial, chargé de transmettre une partie des efforts depuis le crochet (pôle inférieur), directement au pôle supérieur. De plus, la zone latérale cylindrique est soumise à un faible champ de tensions circonférencielles. Ainsi, deux paramètres permettent de faire évoluer la distribution des tensions et la forme de l'enveloppe: - la tension du câble de liaison entre pôles (ou la longueur de ce câble) - la tension circonférencielle moyenne désirée (ou le rayon du ballon). On peut donc calculer et réaliser: - soit des ballons de forme adaptée, comme les ballons à fond plat pour le bon fonctionnement des montgolfières infrarouge (projet MIR); - soit des ballons optimisés pour une bonne répartition des contraintes et une meilleure utilisation des matériaux d'enveloppe, pour l'ensemble des programmes stratosphériques. Il s'ensuit une économie sensible des coûts de fabrication, une fiabilité accrue du fonctionnement de ces ballons et une rendement opérationnel bien supérieur, permettant entre autres, d'envisager des vols à très haute altitude en matériaux très légers.

  8. New target ion source systems at GANIL/SPIRAL1: Prospective

    NASA Astrophysics Data System (ADS)

    Jardin, P.; Bajeat, O.; Delahaye, P.; Dubois, M.; Frigot, R.; Kuchi, V.; Leboucher, C.; Maunoury, L.

    2016-06-01

    SPIRAL1 facility is currently under transformation (Dubois) [1] in order to extend the range of radioactive ion beam offered to users. It will be able to host a larger variety of target ion source systems by the end of 2016, needed to fulfil the production requirements related to the chemical variety of the isotopes demanded by the physicists. The extent of the transformation is limited by the frame of the safety regulation and by the existing facility. Several combinations of mono-charged or multi-charged ECR, FEBIAD and surface ionization sources with new target materials are becoming possible. Some of these combinations are already under test. A comparison between expected SPIRAL1 performances and results obtained in other facilities is presented with the aim of leading our next developments.

  9. Spectra of multiply charged hollow ions in the plasma produced by a short-wavelength nanosecond laser

    SciTech Connect

    Abdallah, J; Skobelev, I Yu; Faenov, A Ya; Magunov, A I; Pikuz, T A; Flora, F; Bollanti, S; DiLazzaro, P; Letardi, T; Burattini, E; Grilli, A; Reale, A; Palladino, L; Tomassetti, G; Scafati, A; Reale, L

    2000-08-31

    Complex spectral structures located between the resonance lines of H- and He-like MgXII and MgXI ions were recorded in experiments on plasma heating by the radiation of a low-power short-wavelength excimer XeCl laser (12-ns pulses with an energy of 2 J). The above spectral structures were shown to arise from transitions in the so-called hollow multicharged ions, i.e., in ions with an empty 1s-shell, which were previously observed in laser produced plasmas only with ultrahigh-power femto- and picosecond laser facilities having extremely high-contrast laser pulses. (interaction of laser radiation with matter. laser plasma)

  10. Developpement des betons semi autoplacants a rheologie adaptee pour des infrastructures

    NASA Astrophysics Data System (ADS)

    Sotomayor Cruz, Cristian Daniel

    BSAP-I optimisés à travers une caractérisation complète des propriétés mécaniques et de la durabilité a été réalisée. A la suite de cette étude, les résultats obtenus nous permettent de conclure que : (1) L'utilisation d'un BSAP-I avec un gros granulat de 5 - 14 mm, des rapports E/L = 0,37 et S/G = 0,52 et une teneur en air de 6 à 9% a été possible en conférant un équilibre optimal fluidité / stabilité à l'état frais, ainsi qu'un niveau de thixotropie adéquate au chantier permettant d'optimiser la conception du coffrage des piliers de pont et de conférer des qualités de surfaces très acceptables de ces infrastructures. (2) La méthode adaptée pour l'essai L-Box contenant 2 barres et une vibration de 5 secondes a permis de bien caractériser la capacité de remplissage d'un BSAP-I. (3) L'utilisation d'un plan factoriel 23 a permis d'obtenir des modèles statistiques fiables, capables de prédire les propriétés rhéologiques à l'état frais et les résistances en compression des BSAP-I avec des dosages en liant entre 370 et 420 kg/m3, des rapports E/L entre 0,34 et 0,40 et S/G entre 0,47 et 0,53. (4) Des mesures de vitesse d'écoulement T40 d'un BSAP-I sont très semblables à celles d'un BAP. En plus, des valeurs T40 montrent une bonne corrélation linéaire avec celles de T400 mesurés dans la boîte L-Box. (5) À la frontière du BAP et du BCV, une bande rhéologique possédant un τ0 entre 30 et 320 Pa et un η entre 10 et 140 Pa.s a été trouvée pour la conception optimale des BSAP-I. (6) Les BSAP-I optimisés ont également conféré une très bonne performance à l'état frais, en permettant maintenir un bon équilibre entre la rhéologie et la stabilité dans le temps, lorsqu'on utilise une énergie de vibration minimale pour amorcer son écoulement. (7) À l'état durci Les BSAP-I ont conféré une bonne performance présentant des résistances mécaniques élevées et des niveaux négligeables de pénétration aux ions chlores

  11. Interaction of multiply charged ions with solid surfaces

    SciTech Connect

    Havener, C.C.; Reed, K.J.; Snowdon, K.J.; Zehner, D.M.; Meyer, F.W.

    1988-01-01

    The observation of the decay of inner-shell vacancies can serve as an excellent probe of the neutralization of multicharged ions during their approach to a metal surface. Several recent experiments that have measured electrons emitted during this neutralization are discussed. Measurements of the total electron yield for incident ions with inner-shell vacancies first showed marked differences from the yield observed for lower charge states and indicated the need for further investigations. Measurements of the emitted electron energy distributions have led to a qualitative understanding of the timescales of the neutralization process. For incident ions with high enough energies, projectile inner-shell vacancies have been observed to survive the neutralization process above the surface and then to be transferred to target atoms in close collisions. The inner-shell reactions occurring in such close collisions are analogous to those that have been observed in ion-atom and ion-foil collisions. Recent measurements of angular distributions of the electrons emitted due to the decay of target vacancies created during the interaction show evidence of the projectile penetrating several layers below the surface. 27 refs., 7 figs.

  12. Proceedings of the 10th international workshop on ECR ion sources

    SciTech Connect

    Meyer, F W; Kirkpatrick, M I

    1991-01-01

    This report contains papers on the following topics: Recent Developments and Future Projects on ECR Ion Sources; Operation of the New KVI ECR Ion Source at 10 GHz; Operational Experience and Status of the INS SF-ECR Ion Source; Results of the New ECR4'' 14.5 GHz ECRIS; Preliminary Performance of the AECR; Experimental Study of the Parallel and Perpendicular Particle Losses from an ECRIS Plasma; Plasma Instability in Electron Cyclotron Resonance Heated Ion Sources; The Hyperbolic Energy Analyzer; Status of ECR Source Development; The New 10 GHz CAPRICE Source; First Operation of the Texas A M ECR Ion Source; Recent Developments of the RIKEN ECR Ion Sources; The 14 GHz CAPRICE Source; Characteristics and Potential Applications of an ORNL Microwave ECR Multicusp Plasma Ion Source; ECRIPAC: The Production and Acceleration of Multiply Charged Ions Using an ECR Plasma; ECR Source for the HHIRF Tandem Accelerator; Feasibility Studies for an ECR-Generated Plasma Stripper; Production of Ion Beams by using the ECR Plasmas Cathode; A Single Stage ECR Source for Efficient Production of Radioactive Ion Beams; The Single Staged ECR Source at the TRIUMF Isotope Separator TISOL; The Continuous Wave, Optically Pumped H{sup {minus}} Source; The H{sup +} ECR Source for the LAMPF Optically Pumped Polarized Ion Source; Present Status of the Warsaw CUSP ECR Ion Source; An ECR Source for Negative Ion Production; GYRAC-D: A Device for a 200 keV ECR Plasma Production and Accumulation; Status Report of the 14.4 GHZ ECR in Legnaro; Status of JYFL-ECRIS; Report on the Uppsala ECRIS Facility and Its Planned Use for Atomic Physics; A 10 GHz ECR Ion Source for Ion-Electron and Ion-Atom Collision Studies; and Status of the ORNL ECR Source Facility for Multicharged Ion Collision Research.

  13. La microscopie ionique analytique des tissus biologiques

    NASA Astrophysics Data System (ADS)

    Galle, P.

    Proposed in 1960 by R. Castaing and G. Slodzian, secondary ion emission microanalysis is a microanalytical method which is now largely used for the study of inert material. The instrument called the analytical ion microscope can also be used for the study of biological spécimens ; images representing the distribution of a given stable or radioactive isotope in a tissue section are obtained with a resolution of 0.5 μm. Among the characteristics of this method, two are of particular interest in biological research : its capacity for isotopic analysis and its very high sensitivity which makes possible for the first time a chemical analysis of element at a very low or even at a trace concentration in a microvolume. Proposé en 1960 par R. Castaing et G. Slodzian, la microanalyse par émission ionique secondaire est une méthode qui permet, entre autre, d'obtenir des images représentant la distribution des isotopes présents à la surface d'un échantillon solide avec une résolution de 0,5 μm. D'intérêt très général, cette méthode a été d'abord largement utilisée pour l'étude des matériaux inertes. Elle offre en outre des possibilités entièrement nouvelles dans le domaine de la recherche biomédicale. L'instrument réalisé, le microscope ionique analytique présente deux caractéristiques particulièrement intéressantes pour la biologie : la possibilité d'analyse isotopique, et l'extrême sensibilité permettant de détecter et de localiser dans une coupe histologique des éléments à des concentrations très faibles voire à l'état de trace.

  14. Elucidating the mechanism behind the stabilization of multi-charged metal cations in water: A case study of the electronic states of microhydrated Mg2+, Ca2+ and Al3+”

    SciTech Connect

    Miliordos, Evangelos; Xantheas, Sotiris S.

    2014-04-21

    Metal atoms typically have second and higher ionization potentials (IPs) that are larger than the IP of water, resulting in the Coulombic explosion of the first few [M(H2O)n]+q (q ≥ 2) clusters as the M+ + (H2O)n + or MOH+ + H3O+(H2O)n energy levels are energetically more stable than the M2+ + (H2O)n ones for small n. We present a theoretical analysis of the various electronic states correlating with the above channels that are involved in the sequential hydration of the Ca2+, Mg2+ and Al3+ cations with up to six water molecules that, for the first time, quantifies their relative shift with the degree of solvation accounting for the observed stabilization of those multi-charged metal cations in an aqueous solution. *

  15. Self-proton/ion radiography of laser-produced proton/ion beam from thin foil targets

    SciTech Connect

    Paudel, Y.; Renard-Le Galloudec, N.; Kantsyrev, V. L.; Safronova, A. S.; Shrestha, I.; Osborne, G. C.; Shlyaptseva, V. V.; Sentoku, Y.; Nicolai, Ph.; D'Humieres, E.; Faenov, A.Ya.

    2012-12-15

    Protons and multicharged ions generated from high-intensity laser interactions with thin foil targets have been studied with a 100 TW laser system. Protons/ions with energies up to 10 MeV are accelerated either from the front or the rear surface of the target material. We have observed for the first time that the protons/ions accelerated from the front surface of the target, in a direction opposite to the laser propagation direction, are turned around and pulled back to the rear surface, in the laser propagation direction. This proton/ion beam is able to create a self-radiograph of the target and glass stalk holding the target itself recorded through the radiochromic film stack. This unique result indicates strong long-living (ns time scale) magnetic fields present in the laser-produced plasma, which are extremely important in energy transport during the intense laser irradiation. The magnetic field from laser main pulse expands rapidly in the preformed plasma to rotate the laser produced protons. Radiation hydrodynamic simulations and ray tracing found that the magnetic field created by the amplified spontaneous emission prepulse is not sufficient to explain the particle trajectories, but the additional field created by the main pulse interaction estimated from particle-in-cell simulation is able to change the particle trajectories.

  16. Des Vents et des Jets Astrophysiques

    NASA Astrophysics Data System (ADS)

    Sauty, C.

    well expected result from the theory. Although, collimation may be conical, paraboloidal or cylindrical (Part 4), cylindrical collimation is the more likely to occur. The shape of outflows may then be used as a tool to predict physical conditions on the flows or on their source. L'éjection continue de plasma autour d'objets massifs est un phénomène largement répandu en astrophysique, que ce soit sous la forme du vent solaire, de vents stellaires, de jets d'étoiles en formation, de jets stellaires autour d'objets compacts ou de jets extra-galactiques. Cette zoologie diversifiée fait pourtant l'objet d'un commun effort de modélisation. Le but de cette revue est d'abord de présenter qualitativement le développement, depuis leur origine, des diverses théories de vents (Partie 1) et l'inter disciplinarité dans ce domaine. Il s'agit d'une énumération, plus ou moins exhaustive, des idées proposées pour expliquer l'accélération et la morphologie des vents et des jets, accompagnée d'une présentation sommaire des aspects observationnels. Cette partie s'abstient de tout aspect faisant appel au formalisme mathématique. Ces écoulements peuvent être décrits, au moins partiellement, en résolvant les équations magnétohydrodynamiques, axisymétriques et stationnaires. Ce formalisme, à la base de la plupart des théories, est exposé dans la Partie 2. Il permet d'introduire quantitativement les intégrales premières qu'un tel système possède. Ces dernières sont amenées à jouer un rôle important dans la compréhension des phénomènes d'accélération ou de collimation, en particulier le taux de perte de masse, le taux de perte de moment angulaire ou l'énergie du rotateur magnétique. La difficulté de modélisation réside dans l'existence de points critiques, propres aux équations non linéaires, qu'il faut franchir. La nature physique et la localisation de ces points critiques fait l'objet d'un débat important car ils sont la clef de voute de la r

  17. First results of 28 GHz superconducting electron cyclotron resonance ion source for KBSI accelerator

    NASA Astrophysics Data System (ADS)

    Park, Jin Yong; Lee, Byoung-Seob; Choi, Seyong; Kim, Seong Jun; Ok, Jung-Woo; Yoon, Jang-Hee; Kim, Hyun Gyu; Shin, Chang Seouk; Hong, Jonggi; Bahng, Jungbae; Won, Mi-Sook

    2016-02-01

    The 28 GHz superconducting electron cyclotron resonance (ECR) ion source has been developed to produce a high current heavy ion for the linear accelerator at KBSI (Korea Basic Science Institute). The objective of this study is to generate fast neutrons with a proton target via a p(Li,n)Be reaction. The design and fabrication of the essential components of the ECR ion source, which include a superconducting magnet with a liquid helium re-condensed cryostat and a 10 kW high-power microwave, were completed. The waveguide components were connected with a plasma chamber including a gas supply system. The plasma chamber was inserted into the warm bore of the superconducting magnet. A high voltage system was also installed for the ion beam extraction. After the installation of the ECR ion source, we reported the results for ECR plasma ignition at ECRIS 2014 in Russia. Following plasma ignition, we successfully extracted multi-charged ions and obtained the first results in terms of ion beam spectra from various species. This was verified by a beam diagnostic system for a low energy beam transport system. In this article, we present the first results and report on the current status of the KBSI accelerator project.

  18. First results of 28 GHz superconducting electron cyclotron resonance ion source for KBSI accelerator.

    PubMed

    Park, Jin Yong; Lee, Byoung-Seob; Choi, Seyong; Kim, Seong Jun; Ok, Jung-Woo; Yoon, Jang-Hee; Kim, Hyun Gyu; Shin, Chang Seouk; Hong, Jonggi; Bahng, Jungbae; Won, Mi-Sook

    2016-02-01

    The 28 GHz superconducting electron cyclotron resonance (ECR) ion source has been developed to produce a high current heavy ion for the linear accelerator at KBSI (Korea Basic Science Institute). The objective of this study is to generate fast neutrons with a proton target via a p(Li,n)Be reaction. The design and fabrication of the essential components of the ECR ion source, which include a superconducting magnet with a liquid helium re-condensed cryostat and a 10 kW high-power microwave, were completed. The waveguide components were connected with a plasma chamber including a gas supply system. The plasma chamber was inserted into the warm bore of the superconducting magnet. A high voltage system was also installed for the ion beam extraction. After the installation of the ECR ion source, we reported the results for ECR plasma ignition at ECRIS 2014 in Russia. Following plasma ignition, we successfully extracted multi-charged ions and obtained the first results in terms of ion beam spectra from various species. This was verified by a beam diagnostic system for a low energy beam transport system. In this article, we present the first results and report on the current status of the KBSI accelerator project.

  19. First results of 28 GHz superconducting electron cyclotron resonance ion source for KBSI accelerator.

    PubMed

    Park, Jin Yong; Lee, Byoung-Seob; Choi, Seyong; Kim, Seong Jun; Ok, Jung-Woo; Yoon, Jang-Hee; Kim, Hyun Gyu; Shin, Chang Seouk; Hong, Jonggi; Bahng, Jungbae; Won, Mi-Sook

    2016-02-01

    The 28 GHz superconducting electron cyclotron resonance (ECR) ion source has been developed to produce a high current heavy ion for the linear accelerator at KBSI (Korea Basic Science Institute). The objective of this study is to generate fast neutrons with a proton target via a p(Li,n)Be reaction. The design and fabrication of the essential components of the ECR ion source, which include a superconducting magnet with a liquid helium re-condensed cryostat and a 10 kW high-power microwave, were completed. The waveguide components were connected with a plasma chamber including a gas supply system. The plasma chamber was inserted into the warm bore of the superconducting magnet. A high voltage system was also installed for the ion beam extraction. After the installation of the ECR ion source, we reported the results for ECR plasma ignition at ECRIS 2014 in Russia. Following plasma ignition, we successfully extracted multi-charged ions and obtained the first results in terms of ion beam spectra from various species. This was verified by a beam diagnostic system for a low energy beam transport system. In this article, we present the first results and report on the current status of the KBSI accelerator project. PMID:26931935

  20. Results of a new OCTOPUS'' ECR ion source at 6. 4 GHz

    SciTech Connect

    Dupont, C.; Jongen, Y. ); Arakawa, K.; Yokota, W. ); Satoh, T.; Tachikawa, T. )

    1990-01-01

    The first OCTOPUS electron cyclstron resonance (ECR) multicharged heavy ion source was built in 1985 at the Centre de Recherches du Cyclotron of the University of Louvain (Belgium). This first source used an ECR frequency of 14.3 GHz in the injector stage and 8.5 GHz in the main confinement stage. A new OCTOPUS source has now been built for a new cyclotron to be installed at the Japan Atomic Energy Research Institute (JAERI). The design of this new OCTOPUS source is identical to the first OCTOPUS source, but uses an ECR frequency of 6.4 GHz in the main confinement stage. The experimental results are described, and a comparison is made between the two sources. However, the available data does not allow any clear conclusion to be drawn on frequency scaling.

  1. Injectabilite des coulis de ciment dans des milieux fissures

    NASA Astrophysics Data System (ADS)

    Mnif, Thameur

    Le travail presente ici est un bilan du travaux de recherche effectues sur l'injectabilite des coulis de ciment dans lu milieux fissures. Un certain nombre de coulis a base de ciment Portland et microfin ont ete selectionnes afin de caracteriser leur capacite a penetrer des milieux fissures. Une partie des essais a ete menee en laboratoire. L'etude rheologique des differents melanges a permis de tester l'influence de l'ajout de superplastifiant et/ou de fumee de silice sur la distribution granulometrique des coulis et par consequent sur leur capacite a injecter des colonnes de sable simulant un milieu fissure donne. La classe granulometrique d'un coulis, sa stabilite et sa fluidite sont apparus comme les trois facteurs principaux pour la reussite d'une injection. Un facteur de finesse a ete defini au cours de cette etude: base sur la classe granulometrique du ciment et sa stabilite, il peut entrer dans la formulation theorique du debit d'injection avant application sur chantier. La deuxieme et derniere partie de l'etude presente les resultats de deux projets de recherche sur l'injection realises sur chantier. L'injection de dalles de beton fissurees a permis le suivi de l'evolution des pressions avec la distance au point d'injection. L'injection de murs de maconnerie a caractere historique a montre l'importance de la definition de criteres de performance des coulis a utiliser pour traiter un milieu donne et pour un objectif donne. Plusieurs melanges peuvent ainsi etre predefinis et mis a disposition sur le chantier. La complementarite des ciments traditionnels et des ciments microfins devient alors un atout important. Le choix d'utilisation de ces melanges est fonction du terrain rencontre. En conclusion, cette recherche etablit une methodologie pour la selection des coulis a base de ciment et des pressions d'injection en fonction de l'ouverture des fissures ou joints de construction.

  2. A review of ion sources for medical accelerators (invited).

    PubMed

    Muramatsu, M; Kitagawa, A

    2012-02-01

    There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespread since the 1990s. The energy and intensity are typically over 200 MeV and several 10(10) pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV∕u. Although the beam intensity depends on the irradiation method, it is typically several 10(8) or 10(9) pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are

  3. Influence des défauts de la structure du verre sur la résistance mécanique des fibres optiques

    NASA Astrophysics Data System (ADS)

    Chmel, A.; Baptizmanski, V. V.; Kharshak, A. A.

    1992-12-01

    For silica (pure and doped) optical fibers prepared from preforms irradiated by thermal neutrons and Ar^+ ions, the measurements of lifetime under transverse stress were carried out. It is found that the neutron bombardment leads to decrease of the lifetime and the strength of fiber while the ion implantation results in increasing of these parameters. The influence of particle irradiation on the glass strength is explained by the generation of structural defects which were observed by the infrared an Raman spectroscopy methods. The direction of the change of mechanical properties of fibers is determined by the type of defects and their distribution in the cross-section of fiber. Des préformes de fibres optiques de silice ont été exposées à un bombardement par des faisceaux de neutrons thermiques et d'ions Ar^+ à énergie de 40 keV afin d'engendrer des défauts de la structure respectivement dans le volume ou dans la couche superficielle des échantillons. Les fibres obtenues des préformes irradiées et non irradiées ont été mises en charge de flexion. On a déterminé leur temps de rupture sous diverses contraintes de traction sur la surface extérieure de la fibre en flexion. On a observé une diminution du temps de rupture des fibres après le bombardement neutronique et une augmentation après l'implantation ionique. L'analyse de la nature des défauts en faisant appel à la spectroscopie infrarouge et Raman a fait ressortir que l'irradiation aux ions entraînait essentiellement des liaisons chimiques dans une fine couche superficielle de l'échantillon alors que l'irradiation aux neutrons occasionnait une déformation des zones du réseau silicique dans toute la section de la préforme et de la fibre. L'amélioration de la résistance mécanique s'explique par une augmentation de la mobilité des éléments structuraux de la matrice de verre par suite d'une rupture partielle des liaisons chimiques et sa diminution par l'apparition de concentrateurs

  4. Grundlagen des Tissue Engineering

    NASA Astrophysics Data System (ADS)

    Mayer, Jörg; Blum, Janaki; Wintermantel, Erich

    Die Organtransplantation stellt eine verbreitete Therapie dar, um bei krankheitsoder unfallbedingter Schädigung eines Organs die Gesamtheit seiner Funktionen wieder herzustellen, indem es durch ein Spenderorgan ersetzt wird. Organtransplantationen werden für die Leber, die Niere, die Lunge, das Herz oder bei schweren grossflächigen Verbrennungen der Haut vorgenommen. Der grosse apparative, personelle und logistische Aufwand und die Risiken der Transplantationschirurgie (Abstossungsreaktionen) sowie die mangelnde Verfügbarkeit von immunologisch kompatiblen Spenderorganen führen jedoch dazu, dass der Bedarf an Organtransplantaten nur zu einem sehr geringen Teil gedeckt werden kann. Sind Spenderorgane nicht verfügbar, können in einzelnen Fällen lebenswichtige Teilfunktionen, wie beispielsweise die Filtrationsfunktion der Niere durch die Blutreinigung mittels Dialyse ersetzt oder, bei mangelnder Funktion der Bauchspeicheldrüse (Diabetes), durch die Verabreichung von Insulin ein normaler Zustand des Gesamtorganismus auch über Jahre hinweg erhalten werden. Bei der notwendigen lebenslangen Anwendung apparativer oder medikamentöser Therapie können für den Patienten jedoch häufig schwerwiegende, möglicherweise lebensverkürzende Nebenwirkungen entstehen. Daher werden in der Forschung Alternativen gesucht, um die Funktionen des ausgefallenen Organs durch die Implantation von Zellen oder in vitro gezüchteten Geweben möglichst umfassend wieder herzustellen. Dies erfordert biologisch aktive Implantate, welche die für den Stoffwechsel des Organs wichtigen Zellen enthalten und einen organtypischen Stoffwechsel entfalten.

  5. Reticulation des fibres lignocellulosiques

    NASA Astrophysics Data System (ADS)

    Landrevy, Christel

    Pour faire face à la crise économique la conception de papier à valeur ajoutée est développée par les industries papetières. Le but de se projet est l'amélioration des techniques actuelles de réticulation des fibres lignocellulosiques de la pâte à papier visant à produire un papier plus résistant. En effet, lors des réactions de réticulation traditionnelles, de nombreuses liaisons intra-fibres se forment ce qui affecte négativement l'amélioration anticipée des propriétés physiques du papier ou du matériau produit. Pour éviter la formation de ces liaisons intra-fibres, un greffage sur les fibres de groupements ne pouvant pas réagir entre eux est nécessaire. La réticulation des fibres par une réaction de « click chemistry » appelée cycloaddition de Huisgen entre un azide et un alcyne vrai, catalysée par du cuivre (CuAAC) a été l'une des solutions trouvée pour remédier à ce problème. De plus, une adaptation de cette réaction en milieux aqueux pourrait favoriser son utilisation en milieu industriel. L'étude que nous désirons entreprendre lors de ce projet vise à optimiser la réaction de CuAAC et les réactions intermédiaires (propargylation, tosylation et azidation) sur la pâte kraft, en milieu aqueux. Pour cela, les réactions ont été adaptées en milieu aqueux sur la cellulose microcristalline afin de vérifier sa faisabilité, puis transférée à la pâte kraft et l'influence de différents paramètres comme le temps de réaction ou la quantité de réactifs utilisée a été étudiée. Dans un second temps, une étude des différentes propriétés conférées au papier par les réactions a été réalisée à partir d'une série de tests papetiers optiques et physiques. Mots Clés Click chemistry, Huisgen, CuAAC, propargylation, tosylation, azidation, cellulose, pâte kraft, milieu aqueux, papier.

  6. Excitation of atoms and molecules in collisions with highly charged ions. [Cyclotron Inst. , Texas A M Univ. , College Station, Texas

    SciTech Connect

    Watson, R.L.

    1993-01-01

    A study of the double ionization of He by high-energy N[sup 7+] ions was extended up in energy to 40 MeV/amu. Coincidence time-of-flight studies of multicharged N[sub 2], O[sub 2], and CO molecular ions produced in collisions with 97-MeV Ar[sup 14+] ions were completed. Analysis of the total kinetic energy distributions and comparison with the available data for CO[sup 2+] and CO[sup 3+] from synchrotron radiation experiments led to the conclusion that ionization by Ar-ion impact populates states having considerably higher excitation energies than those accessed by photoionization. The dissociation fractions for CO[sup 1+] and CO[sup 2+] molecular ions, and the branching ratios for the most prominent charge division channels of CO[sup 2+] through CO[sup 7+] were determined from time-of-flight singles and coincidence data. An experiment designed to investigate the orientation dependence of dissociative multielectron ionization of molecules by heavy ion impact was completed. Measurements of the cross sections for K-shell ionization of intermediate-Z elements by 30-MeV/amu H, N, Ne, and Ar ions were completed. The cross sections were determined for solid targets of Z = 13, 22, 26, 29, 32, 40, 42, 46, and 50 by recording the spectra of K x rays with a Si(Li) spectrometer.

  7. Excitation of atoms and molecules in collisions with highly charged ions. Progress report, January 1, 1990--December 1, 1992

    SciTech Connect

    Watson, R.L.

    1993-01-01

    A study of the double ionization of He by high-energy N{sup 7+} ions was extended up in energy to 40 MeV/amu. Coincidence time-of-flight studies of multicharged N{sub 2}, O{sub 2}, and CO molecular ions produced in collisions with 97-MeV Ar{sup 14+} ions were completed. Analysis of the total kinetic energy distributions and comparison with the available data for CO{sup 2+} and CO{sup 3+} from synchrotron radiation experiments led to the conclusion that ionization by Ar-ion impact populates states having considerably higher excitation energies than those accessed by photoionization. The dissociation fractions for CO{sup 1+} and CO{sup 2+} molecular ions, and the branching ratios for the most prominent charge division channels of CO{sup 2+} through CO{sup 7+} were determined from time-of-flight singles and coincidence data. An experiment designed to investigate the orientation dependence of dissociative multielectron ionization of molecules by heavy ion impact was completed. Measurements of the cross sections for K-shell ionization of intermediate-Z elements by 30-MeV/amu H, N, Ne, and Ar ions were completed. The cross sections were determined for solid targets of Z = 13, 22, 26, 29, 32, 40, 42, 46, and 50 by recording the spectra of K x rays with a Si(Li) spectrometer.

  8. The Spectr-W3 database on the spectroscopic properties of atoms and ions

    NASA Astrophysics Data System (ADS)

    Skobelev, I. Yu.; Loboda, P. A.; Gagarin, S. V.; Ivliev, S. V.; Kozlov, A. I.; Morozov, S. V.; Pikuz, S. A.; Pikuz, T. A.; Popova, V. V.; Faenov, A. Ya.

    2016-04-01

    The Spectr-W3 database was developed in 2001-2013 and is available online (http://spectrw3. snz.ru). The database contains information on various spectroscopic constants of atoms and ions such as the wavelengths and probabilities of radiative transitions, energy levels of atoms and ions, ionization potentials, autoionization rates, and the parameters of analytical approximation of cross sections and rates of collisional transitions in atoms and ions. Spectr-W3 presently contains around 450 thousand records and is the world's largest factual database on spectral properties of multicharged ions. A new stage of development of Spectr-W3, which involves adding a new section titled "Emission Spectrograms" to the database, commenced in 2014. In contrast to the already existing sections that contain tabulated data, this new section provides graphical data (with necessary explanatory notes) on the spectrograms of emission of atoms and ions excited in various plasma sources. The structure of sections of the Spectr-W3 database is characterized, and examples of queries and the corresponding search results are given.

  9. Ion implanted dielectric elastomer circuits

    NASA Astrophysics Data System (ADS)

    O'Brien, Benjamin M.; Rosset, Samuel; Anderson, Iain A.; Shea, Herbert R.

    2013-06-01

    Starfish and octopuses control their infinite degree-of-freedom arms with panache—capabilities typical of nature where the distribution of reflex-like intelligence throughout soft muscular networks greatly outperforms anything hard, heavy, and man-made. Dielectric elastomer actuators show great promise for soft artificial muscle networks. One way to make them smart is with piezo-resistive Dielectric Elastomer Switches (DES) that can be combined with artificial muscles to create arbitrary digital logic circuits. Unfortunately there are currently no reliable materials or fabrication process. Thus devices typically fail within a few thousand cycles. As a first step in the search for better materials we present a preliminary exploration of piezo-resistors made with filtered cathodic vacuum arc metal ion implantation. DES were formed on polydimethylsiloxane silicone membranes out of ion implanted gold nano-clusters. We propose that there are four distinct regimes (high dose, above percolation, on percolation, low dose) in which gold ion implanted piezo-resistors can operate and present experimental results on implanted piezo-resistors switching high voltages as well as a simple artificial muscle inverter. While gold ion implanted DES are limited by high hysteresis and low sensitivity, they already show promise for a range of applications including hysteretic oscillators and soft generators. With improvements to implanter process control the promise of artificial muscle circuitry for soft smart actuator networks could become a reality.

  10. Towards a better comprehension of plasma formation and heating in high performances electron cyclotron resonance ion sources (invited).

    PubMed

    Mascali, D; Gammino, S; Celona, L; Ciavola, G

    2012-02-01

    Further improvements of electron cyclotron resonance ion sources (ECRIS) output currents and average charge state require a deep understanding of electron and ion dynamics in the plasma. This paper will discuss the most recent advances about modeling of non-classical evidences like the sensitivity of electron energy distribution function to the magnetic field detuning, the influence of plasma turbulences on electron heating and ion confinement, the coupling between electron and ion dynamics. All these issues have in common the non-homogeneous distribution of the plasma inside the source: the abrupt density drop at the resonance layer regulates the heating regimes (from collective to turbulent), the beam formation mechanism and emittance. Possible means to boost the performances of future ECRIS will be proposed. In particular, the use of Bernstein waves, in preliminary experiments performed at Laboratori Nazionali del Sud (LNS) on MDIS (microwave discharge ion sources)-type sources, has permitted to sustain largely overdense plasmas enhancing the warm electron temperature, which will make possible in principle the construction of sources for high intensity multicharged ions beams with simplified magnetic structures.

  11. Médecine des voyages

    PubMed Central

    Aw, Brian; Boraston, Suni; Botten, David; Cherniwchan, Darin; Fazal, Hyder; Kelton, Timothy; Libman, Michael; Saldanha, Colin; Scappatura, Philip; Stowe, Brian

    2014-01-01

    Résumé Objectif Définir la pratique de la médecine des voyages, présenter les éléments fondamentaux d’une consultation complète préalable aux voyages à des voyageurs internationaux et aider à identifier les patients qu’il vaudrait mieux envoyer en consultation auprès de professionnels de la médecine des voyages. Sources des données Les lignes directrices et les recommandations sur la médecine des voyages et les maladies liées aux voyages publiées par les autorités sanitaires nationales et internationales ont fait l’objet d’un examen. Une recension des ouvrages connexes dans MEDLINE et EMBASE a aussi été effectuée. Message principal La médecine des voyages est une spécialité très dynamique qui se concentre sur les soins préventifs avant un voyage. Une évaluation exhaustive du risque pour chaque voyageur est essentielle pour mesurer avec exactitude les risques particuliers au voyageur, à son itinéraire et à sa destination et pour offrir des conseils sur les interventions les plus appropriées en gestion du risque afin de promouvoir la santé et prévenir les problèmes médicaux indésirables durant le voyage. Des vaccins peuvent aussi être nécessaires et doivent être personnalisés en fonction des antécédents d’immunisation du voyageur, de son itinéraire et du temps qu’il reste avant son départ. Conclusion La santé et la sécurité d’un voyageur dépendent du degré d’expertise du médecin qui offre le counseling préalable à son voyage et les vaccins, au besoin. On recommande à ceux qui donnent des conseils aux voyageurs d’être conscients de l’ampleur de cette responsabilité et de demander si possible une consultation auprès de professionnels de la médecine des voyages pour tous les voyageurs à risque élevé.

  12. Solar-Wind Protons and Heavy Ions Sputtering of Lunar Surface Materials

    SciTech Connect

    Barghouty, N.; Meyer, Fred W; Harris, Peter R

    2011-01-01

    Lunar surface materials are exposed to {approx}1 keV/amu solar-wind protons and heavy ions on almost continuous basis. As the lunar surface consists of mostly oxides, these materials suffer, in principle, both kinetic and potential sputtering due to the actions of the solar-wind ions. Sputtering is an important mechanism affecting the composition of both the lunar surface and its tenuous exosphere. While the contribution of kinetic sputtering to the changes in the composition of the surface layer of these oxides is well understood and modeled, the role and implications of potential sputtering remain unclear. As new potential-sputtering data from multi-charged ions impacting lunar regolith simulants are becoming available from Oak Ridge National Laboratory's MIRF, we examine the role and possible implications of potential sputtering of Lunar KREEP soil. Using a non-equilibrium model we demonstrate that solar-wind heavy ions induced sputtering is critical in establishing the timescale of the overall solar-wind sputtering process of the lunar surface. We also show that potential sputtering leads to a more pronounced and significant differentiation between depleted and enriched surface elements. We briefly discuss the impacts of enhanced sputtering on the composition of the regolith and the exosphere, as well as of solar-wind sputtering as a source of hydrogen and water on the moon.

  13. Energy level properties of 4p{sup 6}4d{sup 3}, 4p{sup 6}4d{sup 2}4f, and 4p{sup 5}4d{sup 4} configurations of the W{sup 35+} ion

    SciTech Connect

    Bogdanovich, P. Kisielius, R.

    2014-11-15

    The ab initio quasirelativistic Hartree–Fock method developed specifically for the calculation of spectroscopic parameters of heavy atoms and highly charged ions was used to derive spectral data for the multicharged tungsten ion W{sup 35+}. The configuration interaction method was applied to include the electron-correlation effects. The relativistic effects were taken into account in the Breit–Pauli approximation for quasirelativistic Hartree–Fock radial orbitals. The energy level spectra, radiative lifetimes τ, and Lande g-factors have been calculated for the 4p{sup 6}4d{sup 3}, 4p{sup 6}4d{sup 2}4f, and 4p{sup 5}4d{sup 4} configurations of the W{sup 35+} ion.

  14. New progress of high current gasdynamic ion source (invited).

    PubMed

    Skalyga, V; Izotov, I; Golubev, S; Sidorov, A; Razin, S; Vodopyanov, A; Tarvainen, O; Koivisto, H; Kalvas, T

    2016-02-01

    The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)-the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller's ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 10(13) cm(-3)) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10(-4)-10(-3) mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ⋅ mm ⋅ mrad have been demonstrated in recent experiments. PMID:26931934

  15. New progress of high current gasdynamic ion source (invited)

    NASA Astrophysics Data System (ADS)

    Skalyga, V.; Izotov, I.; Golubev, S.; Sidorov, A.; Razin, S.; Vodopyanov, A.; Tarvainen, O.; Koivisto, H.; Kalvas, T.

    2016-02-01

    The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller's ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 1013 cm-3) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10-4-10-3 mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ṡ mm ṡ mrad have been demonstrated in recent experiments.

  16. Peste des petits ruminants.

    PubMed

    Parida, S; Muniraju, M; Mahapatra, M; Muthuchelvan, D; Buczkowski, H; Banyard, A C

    2015-12-14

    Peste des petits ruminants virus causes a highly infectious disease of small ruminants that is endemic across Africa, the Middle East and large regions of Asia. The virus is considered to be a major obstacle to the development of sustainable agriculture across the developing world and has recently been targeted by the World Organisation for Animal Health (OIE) and the Food and Agriculture Organisation (FAO) for eradication with the aim of global elimination of the disease by 2030. Fundamentally, the vaccines required to successfully achieve this goal are currently available, but the availability of novel vaccine preparations to also fulfill the requisite for differentiation between infected and vaccinated animals (DIVA) may reduce the time taken and the financial costs of serological surveillance in the later stages of any eradication campaign. Here, we overview what is currently known about the virus, with reference to its origin, updated global circulation, molecular evolution, diagnostic tools and vaccines currently available to combat the disease. Further, we comment on recent developments in our knowledge of various recombinant vaccines and on the potential for the development of novel multivalent vaccines for small ruminants.

  17. Peste des petits ruminants.

    PubMed

    Parida, S; Muniraju, M; Mahapatra, M; Muthuchelvan, D; Buczkowski, H; Banyard, A C

    2015-12-14

    Peste des petits ruminants virus causes a highly infectious disease of small ruminants that is endemic across Africa, the Middle East and large regions of Asia. The virus is considered to be a major obstacle to the development of sustainable agriculture across the developing world and has recently been targeted by the World Organisation for Animal Health (OIE) and the Food and Agriculture Organisation (FAO) for eradication with the aim of global elimination of the disease by 2030. Fundamentally, the vaccines required to successfully achieve this goal are currently available, but the availability of novel vaccine preparations to also fulfill the requisite for differentiation between infected and vaccinated animals (DIVA) may reduce the time taken and the financial costs of serological surveillance in the later stages of any eradication campaign. Here, we overview what is currently known about the virus, with reference to its origin, updated global circulation, molecular evolution, diagnostic tools and vaccines currently available to combat the disease. Further, we comment on recent developments in our knowledge of various recombinant vaccines and on the potential for the development of novel multivalent vaccines for small ruminants. PMID:26443889

  18. Peste des petits ruminants

    PubMed Central

    Parida, S.; Muniraju, M.; Mahapatra, M.; Muthuchelvan, D.; Buczkowski, H.; Banyard, A.C.

    2015-01-01

    Peste des petits ruminants virus causes a highly infectious disease of small ruminants that is endemic across Africa, the Middle East and large regions of Asia. The virus is considered to be a major obstacle to the development of sustainable agriculture across the developing world and has recently been targeted by the World Organisation for Animal Health (OIE) and the Food and Agriculture Organisation (FAO) for eradication with the aim of global elimination of the disease by 2030. Fundamentally, the vaccines required to successfully achieve this goal are currently available, but the availability of novel vaccine preparations to also fulfill the requisite for differentiation between infected and vaccinated animals (DIVA) may reduce the time taken and the financial costs of serological surveillance in the later stages of any eradication campaign. Here, we overview what is currently known about the virus, with reference to its origin, updated global circulation, molecular evolution, diagnostic tools and vaccines currently available to combat the disease. Further, we comment on recent developments in our knowledge of various recombinant vaccines and on the potential for the development of novel multivalent vaccines for small ruminants. PMID:26443889

  19. Ion source

    DOEpatents

    Leung, Ka-Ngo; Ehlers, Kenneth W.

    1984-01-01

    A magnetic filter for an ion source reduces the production of undesired ion species and improves the ion beam quality. High-energy ionizing electrons are confined by the magnetic filter to an ion source region, where the high-energy electrons ionize gas molecules. One embodiment of the magnetic filter uses permanent magnets oriented to establish a magnetic field transverse to the direction of travel of ions from the ion source region to the ion extraction region. In another embodiment, low energy 16 eV electrons are injected into the ion source to dissociate gas molecules and undesired ion species into desired ion species.

  20. Fission barriers for the emission of odd-numbered fragments from multicharged C{sub 60} prepared in Ar{sup 8+}-C{sub 60} collisions

    SciTech Connect

    Martin, S.; Chen, L.; Bernard, J.; Buchet-Poulizac, M. C.; Wei, B.; Bredy, R.

    2006-01-15

    We report on measurements of the branching ratios of emission of small C{sub n}{sup +} fragments in asymmetrical fission of highly charged C{sub 60}{sup r+} ions (r=4-6). For the channels corresponding to the emission of one fragment, only small fragments with an even number of carbon atoms are observed. For the channels with the emission of two fragments, successive emission of small fragments with an odd number of carbon atoms has been observed with a surprisingly high branching ratio (30%). In order to reproduce the experimental branching ratios in the framework of a statistical evaporation model, the height of fission barriers for the emission of one odd numbered fragment has to be reduced at higher temperature in order to allow the opening of these channels that are forbidden at lower temperature.

  1. Etude des Abondances de MG et de fe dans la Composante Stellaire des Disques des Galaxies Spirales

    NASA Astrophysics Data System (ADS)

    Beauchamp, Dominique

    Je presente ici une technique d'observation par imagerie des disques stellaires des galaxies spirales. Je tente, a l'aide d'un modele evolutif multiphase, de determiner les abondances de fer et de magnesium dans les disques. Dans ce but, je mesure les indices Mg2 et Fe5270 du systeme de Lick. Ces elements representent un choix judicieux d'indicateurs car ils sont formes par des supernovae de deux types differents ayant des durees de vie differentes. Le rapport d'abondances de ces deux elements est un indicateur du taux de formation des populations stellaires. Je decris, en premier lieu, les observations, la technique de mesure, ainsi que son application. J'analyse ensuite les indices mesures. A partir du modele multiphase, j'explore differents parametres physiques des spirales comme le taux de formation stellaire, l'evolution des abondances, les effets possibles de la presence de la barre, etc.

  2. Classification of 20 DES Supernova with OzDES

    NASA Astrophysics Data System (ADS)

    Davis, T. M.; Kim, A. G.; Macualay, E.; Lidman, C.; Sharp, R.; Tucker, B. E.; Yuan, F.; Zhang, B.; Lewis, G. F.; Sommer, N. E.; Martini, P.; Mould, J.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; Gladney, L.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Nichol, R.; Papadopoulos, A.; Childress, M.; D'Andrea, C.; Smith, M.; Sullivan, M.; Maartens, R.; Gupta, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.

    2015-12-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  3. Classification of 8 DES Supernova with OzDES

    NASA Astrophysics Data System (ADS)

    King, A.; Moller, A.; Sommer, N. E.; Tucker, B. E.; Childress, M. J.; Lewis, G. F.; Lidman, C.; OâNeill, C.; Casas, R.; Castander, F. J.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; Gladney, L.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Nichol, R.; Papadopoulos, A.; D'Andrea, C.; Prajs, S.; Smith, M.; Sullivan, M.; Maartens, R.; Gupta, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.

    2016-09-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  4. Classification of 13 DES supernova with OzDES

    NASA Astrophysics Data System (ADS)

    Sommer, N.; Tucker, B. E.; Moller, A.; Zhang, B.; Macualay, E.; Lidman, C.; Gshwend, J.; Martini, P.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; Gladney, L.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Nichol, R.; Papadopoulos, A.; Childress, M.; D'Andrea, C.; Prajs, S.; Smith, M.; Sullivan, M.; Maartens, R.; Gupta, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.

    2016-09-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  5. Classification of 3 DES Supernovae with OzDES

    NASA Astrophysics Data System (ADS)

    Moller, A.; Tucker, B. E.; Yuan, F.; Lewis, G.; Lidman, C.; Macaulay, E.; Nichol, R.; Papadopoulos, A.; Childress, M.; D'Andrea, C.; Smith, M.; Sullivan, M.; Maartens, R.; Gupta, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; Gladney, L.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.

    2016-02-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  6. Classification of 2 DES supernova with OzDES

    NASA Astrophysics Data System (ADS)

    O'Neill, C. R.; Moller, A.; Sommer, N. E.; Tucker, B. E.; Childress, M. J.; Lewis, G. F.; Lidman, C.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; D'Andrea, C.; Gladney, L.; March, M.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Macaulay, E.; Nichol, R.; Prajs, S.; Smith, M.; Sullivan, M.; Maartens, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Gupta, R.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Papadopoulos, A.; Morganson, E.

    2016-10-01

    We report new spectroscopic classifications by OzDES of supernovae discovered by the Dark Energy Survey (ATEL #4668). The spectra (370-885nm) were obtained with the AAOmega Spectrograph (Saunders et al. 2004, SPIE, 5492, 389) and the 2dF fibre positioner at the Anglo-Australian Telescope (AAT).

  7. L'astronomie des Anciens

    NASA Astrophysics Data System (ADS)

    Nazé, Yaël

    2009-04-01

    Quelle que soit la civilisation à laquelle il appartient, l'être humain cherche dans le ciel des réponses aux questions qu'il se pose sur son origine, son avenir et sa finalité. Le premier mérite de ce livre est de nous rappeler que l'astronomie a commencé ainsi à travers les mythes célestes imaginés par les Anciens pour expliquer l'ordre du monde et la place qu'ils y occupaient. Mais les savoirs astronomiques passés étaient loin d'être négligeables et certainement pas limités aux seuls travaux des Grecs : c'est ce que l'auteur montre à travers une passionnante enquête, de Stonehenge à Gizeh en passant par Pékin et Mexico, fondée sur l'étude des monuments anciens et des sources écrites encore accessibles. Les tablettes mésopotamiennes, les annales chinoises, les chroniques médiévales, etc. sont en outre d'une singulière utilité pour les astronomes modernes : comment sinon remonter aux variations de la durée du jour au cours des siècles, ou percer la nature de l'explosion qui a frappé tant d'observateurs en 1054 ? Ce livre offre un voyage magnifiquement illustré à travers les âges, entre astronomie et archéologie.

  8. He-like argon, chlorine and sulfur spectra measurement from an Electron Cyclotron Resonance Ion Trap

    NASA Astrophysics Data System (ADS)

    Trassinelli, M.; Boucard, S.; Covita, D. S.; Gotta, D.; Hirtl, A.; Indelicato, P.; LeBigot, É.-O.; dos Santos, J. M. F.; Simons, L. M.; Stingelin, L.; Veloso, J. F. C. A.; Wasser, A.; Zmeskal, J.

    2007-03-01

    We present a new measurement on X-ray spectroscopy of multicharged argon, chlorine and sulfur obtained with the Electron Cyclotron Resonance Ion Trap installed at the Paul Scherrer Institut (Villigen, Switzerland). For this purpose, we used a crystal spectrometer with a spherically bent crystal having an energy resolution of about 0.4 eV. High intensity Kα X-ray spectra were obtained from ions with one 1s hole ranging from almost neutral to heliumlike charge states. In particular we observed the 1s2s 3S1 → 1s2 1S0 M1 and 1s2p 3P2 → 1s2 1S0 M2 transitions in He-like argon, chlorine and sulfur with unprecedented statistics and resolution. The preliminary analysis presented here describes a new technique to measure precisely energy differences between transitions using a Johann-type Bragg spectrometer. A recent characterization of the spectrometer will allow for a drastic reduction of the systematic errors.

  9. HISTRAP: Proposal for a Heavy Ion Storage Ring for Atomic Physics

    SciTech Connect

    Not Available

    1988-11-01

    This paper presents an overview of the physics capabilities of HISTRAP together with a brief description of the facility and a sampling of the beams which will be available for experimentation, and surveys some of the lines of investigation in the physics of multicharged ions, molecular ion spectroscopy, condensed beams, and nuclear physics that will become possible with the advent of HISTRAP. Details of the accelerator design are discussed, including computer studies of beam tracking in the HISTRAP lattice, a discussion of the HHIRF tandem and ECR/RFQ injectors, and a description of the electron beam cooling system. In the past three years, HISTRAP has received substantial support from Oak Ridge National Laboratory management and staff. The project has used discretionary funds to develop hardware prototypes and carry out design studies. Construction has been completed on a vacuum test stand which models 1/16 of the storage ring and has attained a pressure of 4 x 10/sup -12/ Torr; a prototype rf cavity capable of accelerating beams up to 90 MeV/nucleon and decelerating to 20 keV/nucleon; and a prototype dipole magnet, one of the eight required for the HISTRAP lattice. This paper also contains a summary of the work on electron cooling carried out by one of our staff members at CERN. Building structures and services are described. Details of cost and schedule are also discussed. 77 refs.

  10. Extracting ion emission lines from femtosecond-laser plasma x-ray spectra heavily contaminated by spikes

    NASA Astrophysics Data System (ADS)

    Gasilov, S. V.; Faenov, A. Ya.; Pikuz, T. A.; Villoresi, P.; Poletto, L.; Stagira, S.; Calegari, F.; Vozzi, C.; Nisoli, M.

    2007-09-01

    Nowadays charged-coupled device (CCD) detectors are widely used for the registration of multicharged ions x-ray spectra. These spectra are generated in a plasma during interaction of ultrashort, ultraintense laser pulses with solid targets. Strong parasitic radiation from the plasma affects CCD detectors and contaminates resulting spectra, so that spectral features can be completely covered by noise even during measurements with a very short accumulation time. In this work we propose a "mean to median" (M2M) algorithm for noise suppression in femtosecond laser plasma x-ray spectra. Series of spectra is necessary for the identification of corrupted data points by the developed method. The algorithm was tested with model spectra which reflect main features of experimental data. In practice we used it for extracting information about spectral lines of Ne-like Fe ions and He-like Al ions which allowed us to calculate plasma parameters. It is demonstrated that M2M method is able to clean spectra with more than 10% of corrupted pixels. Fluctuations in intensity of spectral lines induced by laser instability do not affect validity of the proposed method.

  11. Extracting ion emission lines from femtosecond-laser plasma x-ray spectra heavily contaminated by spikes

    SciTech Connect

    Gasilov, S. V.; Faenov, A. Ya.; Pikuz, T. A.; Villoresi, P.; Poletto, L.; Stagira, S.; Calegari, F.; Vozzi, C.; Nisoli, M.

    2007-09-15

    Nowadays charged-coupled device (CCD) detectors are widely used for the registration of multicharged ions x-ray spectra. These spectra are generated in a plasma during interaction of ultrashort, ultraintense laser pulses with solid targets. Strong parasitic radiation from the plasma affects CCD detectors and contaminates resulting spectra, so that spectral features can be completely covered by noise even during measurements with a very short accumulation time. In this work we propose a ''mean to median'' (M2M) algorithm for noise suppression in femtosecond laser plasma x-ray spectra. Series of spectra is necessary for the identification of corrupted data points by the developed method. The algorithm was tested with model spectra which reflect main features of experimental data. In practice we used it for extracting information about spectral lines of Ne-like Fe ions and He-like Al ions which allowed us to calculate plasma parameters. It is demonstrated that M2M method is able to clean spectra with more than 10% of corrupted pixels. Fluctuations in intensity of spectral lines induced by laser instability do not affect validity of the proposed method.

  12. Double Coincidence Studies of Molecular Dissociation Induced by Heavy Ion Impact.

    NASA Astrophysics Data System (ADS)

    Sampoll Ramirez, Gabriel

    Multielectron removal from an atom or molecule may be accomplished with high efficiency by the impact of a fast, highly-charged, heavy ion. When a diatomic molecule suffers the loss of electrons, it will generally dissociate into ions having considerable amounts of kinetic energy as a result of their mutual Coulomb repulsion. In the present work, experiments designed to examine the yield and kinetic energy distributions associated with different charge division pathways for the dissociation of multicharged CO, N_2 and O_2 molecular ions were performed. A beam of 96 MeV Ar ^{14+} ions was directed through a differentially pumped gas cell containing the molecules of interest into a microchannel plate detector. Dissociation products produced in ionizing collisions were accelerated out of the gas cell by an electric field into a time-of -flight (TOF) spectrometer. Upon reaching the end of the flight tube, the ions were detected by another set of microchannel plates. An acceptable binary dissociation event was one for which both dissociation-product ions were detected. The TOF of the first ion to reach the detector and the time difference between the arrival of the first ion and its partner were recorded on magnetic tape event-by-event so as to maintain their correlation. Separation of the time-difference (Delta t) distributions into sets correlated with the charge of the first ion was accomplished by off-line sorting of the event-by-event data. Transformation of the Deltat distributions into total kinetic energy distributions (TKED) required a detailed simulation of the ion trajectories in order to construct the response matrix of the spectrometer system. The average total kinetic energies were determined for all the observed dissociation channels and used to calculate the average excitation energies of the parent molecular ions. The TKED of CO^{2+} was in very good agreement with previous measurements obtained in a photoionization study using synchroton radiation. The

  13. Cesium and strontium ion specific exchangers

    SciTech Connect

    Yates, S.

    1996-10-01

    This work is one of two parallel projects that are part of an ESP task to develop high-capacity, selective, solid extractants for cesium, strontium, and technetium from nuclear wastes. In this subtask, Pacific Northwest National Laboratory (PNNL) is collaborating with AlliedSignal, Inc. (Des Plaines, Illinois) to develop inorganic ion exchangers that are selective for strontium and cesium from alkaline high-level waste and groundwater streams.

  14. Transport quantique dans des nanostructures

    NASA Astrophysics Data System (ADS)

    Naud, C.

    2002-09-01

    structure des oscillations de conductance en fonction du flux du champ magnétique de période h/e dont l'amplitude est beaucoup plus importante que celle mesurée sur un réseau carré de même dimension. Cette différence constitue une signature d'un effet de localisation induit par le champ magnétique sur la topologie mathcal{T}3. Pour des valeurs spécifiques du champ magnétique, du fait des interférences destructives Aharonov-Bohm, la propagation des fonctions d'ondes est limitée à un ensemble fini de cellule du réseau appelé cage. De la dépendance en température des oscillations de période h/e mesurées sur le réseau mathcal{T}3 nous avons tiré une longueur caractéristique qui peut être rattachée au périmètre des cages. Un phénomène inattendu fut l'observation, pour des champs magnétiques plus importants, d'un doublement de fréquence des oscillations. Ces oscillations de période h/2e pouvant avoir une amplitude supérieure aux oscillations de période h/e, une interprétation en terme d'harmonique n'est pas possible. Enfin, l'influence de la largeur électrique des fils constituant le réseau et donc celle du nombre de canaux par brin a été étudiée en réalisant des grilles électrostatique. Les variations de l'amplitude des signaux en h/e et h/2e en fonction de la tension de grille ont été mesurés.

  15. Impact de la preparation des anodes crues et des conditions de cuisson sur la fissuration dans des anodes denses

    NASA Astrophysics Data System (ADS)

    Amrani, Salah

    La fabrication de l'aluminium est realisee dans une cellule d'electrolyse, et cette operation utilise des anodes en carbone. L'evaluation de la qualite de ces anodes reste indispensable avant leur utilisation. La presence des fissures dans les anodes provoque une perturbation du procede l'electrolyse et une diminution de sa performance. Ce projet a ete entrepris pour determiner l'impact des differents parametres de procedes de fabrication des anodes sur la fissuration des anodes denses. Ces parametres incluent ceux de la fabrication des anodes crues, des proprietes des matieres premieres et de la cuisson. Une recherche bibliographique a ete effectuee sur tous les aspects de la fissuration des anodes en carbone pour compiler les travaux anterieurs. Une methodologie detaillee a ete mise au point pour faciliter le deroulement des travaux et atteindre les objectifs vises. La majorite de ce document est reservee pour la discussion des resultats obtenus au laboratoire de l'UQAC et au niveau industriel. Concernant les etudes realisees a l'UQAC, une partie des travaux experimentaux est reservee a la recherche des differents mecanismes de fissuration dans les anodes denses utilisees dans l'industrie d'aluminium. L'approche etait d'abord basee sur la caracterisation qualitative du mecanisme de la fissuration en surface et en profondeur. Puis, une caracterisation quantitative a ete realisee pour la determination de la distribution de la largeur de la fissure sur toute sa longueur, ainsi que le pourcentage de sa surface par rapport a la surface totale de l'echantillon. Cette etude a ete realisee par le biais de la technique d'analyse d'image utilisee pour caracteriser la fissuration d'un echantillon d'anode cuite. L'analyse surfacique et en profondeur de cet echantillon a permis de voir clairement la formation des fissures sur une grande partie de la surface analysee. L'autre partie des travaux est basee sur la caracterisation des defauts dans des echantillons d'anodes crues

  16. Induction heating pure vapor source of high temperature melting point materials on electron cyclotron resonance ion source.

    PubMed

    Kutsumi, Osamu; Kato, Yushi; Matsui, Yuuki; Kitagawa, Atsushi; Muramatsu, Masayuki; Uchida, Takashi; Yoshida, Yoshikazu; Sato, Fuminobu; Iida, Toshiyuki

    2010-02-01

    Multicharged ions that are needed are produced from solid pure material with high melting point in an electron cyclotron resonance ion source. We develop an evaporator by using induction heating (IH) with multilayer induction coil, which is made from bare molybdenum or tungsten wire without water cooling and surrounding the pure vaporized material. We optimize the shapes of induction coil and vaporized materials and operation of rf power supply. We conduct experiment to investigate the reproducibility and stability in the operation and heating efficiency. IH evaporator produces pure material vapor because materials directly heated by eddy currents have no contact with insulated materials, which are usually impurity gas sources. The power and the frequency of the induction currents range from 100 to 900 W and from 48 to 23 kHz, respectively. The working pressure is about 10(-4)-10(-3) Pa. We measure the temperature of the vaporized materials with different shapes, and compare them with the result of modeling. We estimate the efficiency of the IH vapor source. We are aiming at the evaporator's higher melting point material than that of iron. PMID:20192343

  17. Induction heating pure vapor source of high temperature melting point materials on electron cyclotron resonance ion source

    SciTech Connect

    Kutsumi, Osamu; Kato, Yushi; Matsui, Yuuki; Sato, Fuminobu; Iida, Toshiyuki; Kitagawa, Atsushi; Muramatsu, Masayuki; Uchida, Takashi; Yoshida, Yoshikazu

    2010-02-15

    Multicharged ions that are needed are produced from solid pure material with high melting point in an electron cyclotron resonance ion source. We develop an evaporator by using induction heating (IH) with multilayer induction coil, which is made from bare molybdenum or tungsten wire without water cooling and surrounding the pure vaporized material. We optimize the shapes of induction coil and vaporized materials and operation of rf power supply. We conduct experiment to investigate the reproducibility and stability in the operation and heating efficiency. IH evaporator produces pure material vapor because materials directly heated by eddy currents have no contact with insulated materials, which are usually impurity gas sources. The power and the frequency of the induction currents range from 100 to 900 W and from 48 to 23 kHz, respectively. The working pressure is about 10{sup -4}-10{sup -3} Pa. We measure the temperature of the vaporized materials with different shapes, and compare them with the result of modeling. We estimate the efficiency of the IH vapor source. We are aiming at the evaporator's higher melting point material than that of iron.

  18. X-ray structure of putative acyl-ACP desaturase DesA2 from Mycobacterium tuberculosis H37Rv

    SciTech Connect

    Dyer, David H.; Lyle, Karen S.; Rayment, Ivan; Fox, Brian G.

    2010-07-13

    Genome sequencing showed that two proteins in Mycobacterium tuberculosis H37Rv contain the metal binding motif (D/E)X{sub 2}HX{sub {approx}100}(D/E)X{sub 2}H characteristic of the soluble diiron enzyme superfamily. These putative acyl-ACP desaturase genes desA1 and desA2 were cloned from genomic DNA and expressed in Escherichia coli BL21(DE3). DesA1 was found to be insoluble, but in contrast, DesA2 was a soluble protein amenable to biophysical characterization. Here, we report the 2.0 {angstrom} resolution X-ray structure of DesA2 determined by multiple anomalous dispersion (MAD) phasing from a Se-met derivative and refinement against diffraction data obtained on the native protein. The X-ray structure shows that DesA2 is a homodimeric protein with a four-helix bundle core flanked by five additional helices that overlay with 192 structurally equivalent amino acids in the structure of stearoyl-ACP {Delta}9 desaturase from castor plant with an rms difference 1.42 {angstrom}. In the DesA2 crystals, one metal (likely Mn from the crystallization buffer) was bound in high occupancy at the B-site of the conserved metal binding motif, while the A-site was not occupied by a metal ion. Instead, the amino group of Lys-76 occupied this position. The relationships between DesA2 and known diiron enzymes are discussed.

  19. Etude des effets du martelage repetitif sur les contraintes residuelles

    NASA Astrophysics Data System (ADS)

    Hacini, Lyes

    L'assemblage par soudage peut engendrer des contraintes residuelles. Ces contraintes provoquent des fissurations prematurees et un raccourcissement de la duree de vie des composants. Dans ce contexte, le martelage robotise est utilise pour relaxer ces contraintes residuelles. Trois volets sont presentes: le premier est l'evaluation des effets des impacts unitaires repetes sur le champ de contraintes developpe dans des plaques d'acier inoxydable austenitique 304L vierges ou contenant des contraintes residuelles initiales. Dans la deuxieme partie de ce projet, le martelage est applique grace au robot SCOMPI. Les contraintes residuelles induites et relaxees par martelage sont ensuite mesurees par la methode des contours, qui a ete adaptee a cet effet. Dans la troisieme partie, le martelage est modelise par la methode des elements finis. Un modele axisymetrique developpe grace au logiciel ANSYS permet de simuler des impacts repetes d'un marteau elastique sur une plaque ayant un comportement elastoplastique.

  20. Ion colliders

    SciTech Connect

    Fischer, W.

    2011-12-01

    Ion colliders are research tools for high-energy nuclear physics, and are used to test the theory of Quantum Chromo Dynamics (QCD). The collisions of fully stripped high-energy ions create matter of a temperature and density that existed only microseconds after the Big Bang. Ion colliders can reach higher densities and temperatures than fixed target experiments although at a much lower luminosity. The first ion collider was the CERN Intersecting Storage Ring (ISR), which collided light ions [77Asb1, 81Bou1]. The BNL Relativistic Heavy Ion Collider (RHIC) is in operation since 2000 and has collided a number of species at numerous energies. The CERN Large Hadron Collider (LHC) started the heavy ion program in 2010. Table 1 shows all previous and the currently planned running modes for ISR, RHIC, and LHC. All three machines also collide protons, which are spin-polarized in RHIC. Ion colliders differ from proton or antiproton colliders in a number of ways: the preparation of the ions in the source and the pre-injector chain is limited by other effects than for protons; frequent changes in the collision energy and particle species, including asymmetric species, are typical; and the interaction of ions with each other and accelerator components is different from protons, which has implications for collision products, collimation, the beam dump, and intercepting instrumentation devices such a profile monitors. In the preparation for the collider use the charge state Z of the ions is successively increased to minimize the effects of space charge, intrabeam scattering (IBS), charge change effects (electron capture and stripping), and ion-impact desorption after beam loss. Low charge states reduce space charge, intrabeam scattering, and electron capture effects. High charge states reduce electron stripping, and make bending and acceleration more effective. Electron stripping at higher energies is generally more efficient. Table 2 shows the charge states and energies in the

  1. ION SOURCE

    DOEpatents

    Martina, E.F.

    1958-04-22

    An improved ion source particularly adapted to provide an intense beam of ions with minimum neutral molecule egress from the source is described. The ion source structure includes means for establishing an oscillating electron discharge, including an apertured cathode at one end of the discharge. The egress of ions from the source is in a pencil like beam. This desirable form of withdrawal of the ions from the plasma created by the discharge is achieved by shaping the field at the aperture of the cathode. A tubular insulator is extended into the plasma from the aperture and in cooperation with the electric fields at the cathode end of the discharge focuses the ions from the source,

  2. Ostéosynthèse des fractures des métacarpiens et des phalanges de la main par mini plaque: à propos de 12 cas

    PubMed Central

    Moncef, Erraji; Abdelhafid, Derfoufi; Abdessamad, Kharraji; Omar, Agoumi; Najib, Abdeljaouad; Abdelkrim, Daoudi; Hicham, Yacoubi

    2016-01-01

    Le traitement des fractures instables des métacarpes et des phalanges reste un objet de controverse. Peu de séries ont été rapportées dans la littérature, rendant leur analyse difficile. Nous rapportons une étude rétrospective comportant 12 patients, opérés par cette technique, ayant eu des fractures déplacées des métacarpes ou des phalanges, sur une période de deux ans. Les résultats globaux ont été bons dans 75% des cas, moyenne dans 16,5% des cas et mauvais dans 8,5% des cas. La stabilité du montage par mini plaques des fractures instables des métacarpiens et des phalanges ont permis une mobilisation précoce des articulations de la main, évitant ainsi la raideur. PMID:27800079

  3. Effective Forces Between Diamagnetic and Paramagnetic Ions in D 2 O at Low and Moderate Ionic Strengths: An NMR Relaxation Study

    NASA Astrophysics Data System (ADS)

    Sacco, A.; Belorizky, E.; Jeannin, M.; Gorecki, W.; Fries, P. H.

    1997-09-01

    Debye-Hückel screening formalism, which can be reasonably used up to moderate ionic strengths. On étudie la dynamique de plusieurs paires d'ions attractifs et répulsifs en solution aqueuseà des forces ioniques atteignant 1 mol l^{-1}. La mesure des taux de relaxation nucléaire longitudinale des protons des ions diamagnétiques fournit l'information expérimentale. On a choisi les solutions ioniques de sorte que le principal mécanique de relaxation de ces protons soit les fluctuations temporelles de leur interaction dipolaire magnétique avec les spins électroniques des ions paramagnétiques. Cette interaction dépend fortement du potentiel des forces moyennes (PMF) ion-ion et des coefficients d'auto-diffusion ioniques. On calcule les corrélations spatiales ion-ion et les PMF associés à l'aide d'une nouvelle approximation des équations intégrales de la mécanique statistique des liquides. Ce formalisme traite tous les ions comme des particules discrètes. Il est fondé sur les PMF d'infinie dilution paires d'ions. Il mélange une théorie de Born-Oppenheimer pour la dilution infinie avec une approximation de type McMillan-Mayer pour tenir compte de la concentration ionique. Il va au-delà du modèle d'écrantage de Debye-Hückel où une distribution continue de charge rend compte des effets des ions discrets environnants. Il est relié au concept des constantes diélectriques locales qui généralisent la constante diélectrique macroscopique usuelle et sont fonction des distances ion-ion. On a mesuré les coefficients d'auto-diffusion des ions diamagnétiques par des techniques RMN de gradients pulsés de champ magnétique (PMFG), appliquées aux protons résonnants. Dans les solutions paramagnétiques contenant plusieurs espèces protonées, les précautions particulières à prendre sont discutées en détail. Dans toutes les solutions considérées la théorie rend bien compte des taux de relaxation en fonction des charges des ions, de leurs

  4. Peste des Petits Ruminants Virus.

    PubMed

    Baron, M D; Diallo, A; Lancelot, R; Libeau, G

    2016-01-01

    Peste des petits ruminants virus (PPRV) causes a severe contagious disease of sheep and goats and has spread extensively through the developing world. Because of its disproportionately large impact on the livelihoods of low-income livestock keepers, and the availability of effective vaccines and good diagnostics, the virus is being targeted for global control and eventual eradication. In this review we examine the origin of the virus and its current distribution, and the factors that have led international organizations to conclude that it is eradicable. We also review recent progress in the molecular and cellular biology of the virus and consider areas where further research is required to support the efforts being made by national, regional, and international bodies to tackle this growing threat. PMID:27112279

  5. Ion Chromatography.

    ERIC Educational Resources Information Center

    Mulik, James D.; Sawicki, Eugene

    1979-01-01

    Accurate for the analysis of ions in solution, this form of analysis enables the analyst to directly assay many compounds that previously were difficult or impossible to analyze. The method is a combination of the methodologies of ion exchange, liquid chromatography, and conductimetric determination with eluant suppression. (Author/RE)

  6. Cancer risk in DES daughters

    PubMed Central

    Verloop, Janneke; van Leeuwen, Flora E.; Helmerhorst, Theo J. M.; van Boven, Hester H.

    2010-01-01

    Objective We examined long-term risk of cancer in women exposed to diethylstilbestrol (DES) in utero. Methods A total of 12,091 DES-exposed women in the Netherlands were followed prospectively from December 1992 till June 2008. Cancer incidence was assessed through linkage with the Dutch pathology database (PALGA) and the Netherlands Cancer Registry and compared with the Dutch female population. Results A total of 348 medically verified cancers occurred; median age at end of follow-up was 44.0 years. No overall increased risk of cancer was found (standardized incidence ratio [SIR] = 1.01; 95% confidence interval [CI] = 0.91, 1.13). The risk of clear cell adenocarcinoma of the vagina and cervix (CCA) was statistically significantly increased (SIR = 24.23; 95% CI = 8.89, 52.74); the elevated risk persisted above 40 years of age. The risk of melanoma diagnosed before age 40 was increased (SIR = 1.59; 95% CI = 1.08, 2.26). No excess risks were found for other sites, including breast cancer. Conclusions Except for an elevated risk of CCA, persisting at older ages, and an increased risk of melanoma at young ages, we found no increased risk of cancer. Longer follow-up is warranted to examine cancer risk at ages when cancer occurs more frequently. Electronic supplementary material The online version of this article (doi:10.1007/s10552-010-9526-5) contains supplementary material, which is available to authorized users. PMID:20204493

  7. The enhancement of existing DES Maplet interface

    NASA Astrophysics Data System (ADS)

    Abdullah, Nur Lina; Mutalip, Rasidah Abdull; Abdullah, Kamilah

    2014-07-01

    This study pertains to the process of Data Encryption Standard, DES. DES consists of encryption and decryption processes linked with mathematical elements such as algebra and number theory. Preliminary, studies revealed that most of mathematics students face a problem in understanding the complicated process of DES. In modern learning methods, learning environment becomes more interesting with the use of computer and a variety of mathematical software packages. Several mathematical softwares such as Maple, Mathematica, Mathlab and Sage were developed in order to fulfill the specific calculation requirements. Correspondingly, motivated from that, this study incorporated with Maple to enhance the existing DES Maplet interface to be more interactive and user-friendly compared to the original version.

  8. Contribution a la comprehension de la durabilite a l'ecaillage des betons contenant de la cendre volante et du laitier

    NASA Astrophysics Data System (ADS)

    Houehanou, Ernesto C.

    similaires apres 4 et 6 annees de service. La microstructure des betons en service a ete analysee au moyen du microscope a balayage electronique (MEB). Les resultats montrent que la qualite du murissement influence grandement la durabilite a l'ecaillage des betons contenant de la cendre volante et de laitier surtout lorsqu'ils sont soumis ' aux essais acceleres en laboratoire. La duree du pretraitement humide est un parametre cle de la durabilite a l'ecaillage des betons testes en laboratoire. Le pretraitement humide correspond a la duree totale du murissement humide (100% HR) et de la periode de presaturation. Pour les deux methodes d'essai, l'allongement du pretraitement humide a 28 jours ameliore la resistance a l'ecaillage de tous les types de betons et en particulier celle des betons avec cendres volantes. Pour les deux methodes d'essai, l'allongement du pretraitement humide a 28 jours ameliore la resistance a l'ecaillage de tous les types de betons et en particulier celle des betons avec cendres volantes. La periode de presaturation de 7 jours de la procedure NQ 2621-900 a un effet similaire a celui d'un murissement humide de meme longueur. Un murissement humide de 28 jours apparait optimal et conduit a une estimation plus realiste de la resistance a l'ecaillage reelle des betons. Pour une meme duree de pretraitement humide, les procedures NQ 2621-900 et ASTM C672 donnent des resultats equivalents. L'utilisation d'un moule a fond drainant n'a pas d'effet sur la resistance a l'ecaillage des betons de cette etude. Bien que le murissement dans l'eau saturee de chaux offre toute l'eau requise pour favoriser le developpement des proprietes du beton et l'amelioration de sa durabilite a l'ecaillage, elle lessive cependant les ions alcalins ce qui diminue defavorablement l'alcalinite et le pH de la solution interstitielle de la pate de ciment pres de la surface exposee. L'utilisation d'un agent de murissement protege mieux les betons contenant de la cendre volante et ameliore

  9. Imagerie Resolue dans le Temps des Photons et Neutres Metastables Emis D'une Surface Par Stimulation Electronique

    NASA Astrophysics Data System (ADS)

    Leclerc, Gregoire

    L'appareil que nous presentons ici a ete mis au point pour permettre d'accumuler des images numeriques, resolues dans le temps, de la desorption par stimulation electronique (DSE) d'ions positifs et negatifs, de photons et de neutres metastables, tout en conservant des capacites de base de diffraction d'electrons lents (DEL) et de transmission d'electrons lents (TEL). Le spectrometre comporte un monochromateur d'electrons a secteur cylindrique de 127^ circ dont l'optique de sortie permet la focalisation du faisceau d'electrons sur une large gamme d'energies. Le detecteur consiste en un empilement de galettes de microcanaux et d'une anode resistive a encodage de division de charges. La reponse spatiale du detecteur a ete calibree et plusieurs causes de non-linearite ont ete localisees et corrigees. Des methodes de correction materielle et logicielle des distorsions spatiales sont presentees. La resolution temporelle des evenements est obtenue en pulsant le faisceau d'electrons, et de facon synchrone la detection, laquelle est couplee a un micro-ordinateur. La premiere partie de ce travail est consacree a la caracterisation du spectrometre et la presentation de nombreux parametres operationnels, obtenus soit au moment de la conception, soit experimentalement. Suit la presentation de donnees de DEL et de DSE pour le systeme Ar/Pt(111) en films minces a 15K. Les sequences temporelles d'images de metastables d'Ar desorbes ont revele la presence de plusieurs populations distinctes, ayant des distributions angulaires et distributions d'energie cinetique que nous avons pu separer. Les fonctions d'excitation de l'emission de photons et de la desorption de differentes composantes de metastables, ainsi que la dependance de ces signaux sur l'epaisseur des films d'Ar, sont aussi presentees et analysees. Les techniques que nous avons developpees ont permis de cerner les mecanismes en jeu pour la desorption et la luminescence.

  10. ION SWITCH

    DOEpatents

    Cook, B.

    1959-02-10

    An ion switch capable of transferring large magnitudes of power is described. An ion switch constructed in accordance with the invention includes a pair of spaced control electrodes disposed in a highly evacuated region for connection in a conventional circuit to control the passing of power therethrough. A controllable ionic conduction path is provided directiy between the control electrodes by a source unit to close the ion switch. Conventional power supply means are provided to trigger the source unit and control the magnitude, durations and pulse repetition rate of the aforementioned ionic conduction path.

  11. Effets perturbateurs endocriniens des pesticides organochlores.

    PubMed

    Charlier, C; Plomteux, G

    2002-01-01

    Xenoestrogens such organochlorine pesticides are known to induce changes in reproductive development, function or behaviour in wildlife. Because these compounds are able to modify the estrogens metabolism, or to compete with estradiol for binding to the estrogen receptor, it may be possible that these products affect the risk of developing impaired fertility, precocious puberty or some kinds of cancer in man. Le plus ancien récit de lutte contre la pollution remonte à une légende indienne racontant que la divinité Sing-bonga était incommodée par les émanations des fours dans lesquels les Asuras fondaient leurs métaux (1). Evidemment depuis, la problématique n-a cessé de s-accroître et la contamination de la Terre par de nombreux polluants est devenue aujourd-hui un problème majeur de notre Société. La protection de notre environnement est une question capitale qui doit être respectée malgré la pression économique actuelle et qui ne cessera de croître au cours des prochaines années même si l-identification objective et indiscutable de ce qui est essentiel - donc devant être prioritairement garanti sur la planète - est difficile à cerner (2). « Un oiseau en mauvais état ne pond pas de bons oeufs » disait un proverbe grec. Mais ce n-est qu-à partir de la seconde moitié du XXème siècle que les toxicologues ont commencé à identifier les effets qu-avaient entraînés à l-échelle mondiale les pollutions émises aux XIXème siècle sur la faune sauvage et sur le cheptel (3). L-histoire contemporaine des pesticides industriels commence vers 1874 (synthèse des organochlorés) et se poursuit tout au long de ces 2 siècles en passant par la synthèse des organophosphorés (1950), des carbamates (1970) et des pyréthroïdes (1975) (4). Le dichlorodiphényltrichloroéthane (DDT) a été synthétisé pour la première fois par un étudiant en cours de préparation de sa thèse de doctorat : Othmer Zeidler. La production, reprise par les

  12. Analysis of x-ray emission in charge-exchange collisions of C6+ ions with He and H2

    NASA Astrophysics Data System (ADS)

    Leung, Anthony C. K.; Kirchner, T.

    2016-05-01

    Charge exchange in C6+-He and - H2 collisions followed by x-ray emission is examined using the two-center basis generator method within the independent electron model. The analysis examines the two collision systems for low to intermediate projectile energies. We perform capture cross section and radiative cascade calculations to obtain Lyman line emission ratios which can be compared to measurements that were carried out at the Oak Ridge National Laboratory Multicharged Ion Research Facility. Single-electron capture is considered for the C6+-He system while both single and autoionizing double capture are considered for the C6+- H2 system. We also examine the effects of a time-dependent screening potential that models target response on the l distribution of the capture cross sections and the emission ratios. Calculated line emission ratios based on the no-response approximation are found to be in satisfactory agreement with the measurements. Work supported by SHARCNET, OGS, and NSERC, Canada

  13. ION SOURCE

    DOEpatents

    Leland, W.T.

    1960-01-01

    The ion source described essentially eliminater the problem of deposits of nonconducting materials forming on parts of the ion source by certain corrosive gases. This problem is met by removing both filament and trap from the ion chamber, spacing them apart and outside the chamber end walls, placing a focusing cylinder about the filament tip to form a thin collimated electron stream, aligning the cylinder, slits in the walls, and trap so that the electron stream does not bombard any part in the source, and heating the trap, which is bombarded by electrons, to a temperature hotter than that in the ion chamber, so that the tendency to build up a deposit caused by electron bombardment is offset by the extra heating supplied only to the trap.

  14. ION SOURCE

    DOEpatents

    Blue, C.W.; Luce, J.S.

    1960-07-19

    An ion source is described and comprises an arc discharge parallel to the direction of and inside of a magnetic field. an accelerating electrode surrounding substantially all of the discharge except for ion exit apertures, and means for establishing an electric field between that electrode and the arc discharge. the electric field being oriented at an acute angle to the magnetic field. Ions are drawn through the exit apertures in the accelrating electrcde in a direction substantially divergent to the direction of the magnetic field and so will travel in a spiral orbit along the magnetic field such that the ions will not strike the source at any point in their orbit within the magnetic field.

  15. Ion focusing

    DOEpatents

    Cooks, Robert Graham; Baird, Zane; Peng, Wen-Ping

    2015-11-10

    The invention generally relates to apparatuses for focusing ions at or above ambient pressure and methods of use thereof. In certain embodiments, the invention provides an apparatus for focusing ions that includes an electrode having a cavity, at least one inlet within the electrode configured to operatively couple with an ionization source, such that discharge generated by the ionization source is injected into the cavity of the electrode, and an outlet. The cavity in the electrode is shaped such that upon application of voltage to the electrode, ions within the cavity are focused and directed to the outlet, which is positioned such that a proximal end of the outlet receives the focused ions and a distal end of the outlet is open to ambient pressure.

  16. Instrumentation pour la spectroscopie laser sur faisceau d'ions rapides

    NASA Astrophysics Data System (ADS)

    Bazin, Marc

    Devant l'emergence des technologies exploitant l'infiniment petit, la spectroscopie atomique et moleculaire devient de plus en plus incontournable pour comprendre precisement les mecanismes quantiques impliques dans l'interaction des molecules. C'est le cas notamment de la nanotechnologie, de la dynamique reactionnelle des gaz a effet de serre ou simplement de l'identification des molecules constituant certains objets de l'astrophysique. Bien qu'un travail considerable soit deja accompli pour comprendre la dissociation ou la formation des molecules simples, il reste a vaincre la complexite des mecanismes impliques lorsque les molecules possedent plus de trois noyaux. Parmi les rares techniques de spectroscopie a tres haute resolution (jusqu'a la structure hyperfine), la spectroscopie laser sur faisceaux d'ions rapides est une methode experimentale eprouvee depuis trois decennies environ. Cette methode spectroscopique fournit des resultats comptant parmi les meilleurs pour obtenir des constantes moleculaires precises et permettre la reduction du spectre moleculaire. Une particularite remarquable de notre instrument est la possibilite d'enregistrer le signal de fragmentation moleculaire par laser via les etats de predissociation de la molecule etudiee. Notre contribution a ete d'ameliorer et de moderniser l'equipement existant. Nous avons augmente la resolution spectrale de notre instrument. Nous avons atteint notre principal objectif, a savoir, la possibilite d'acquerir des spectres selon deux modes : par detection du signal synchronisee sur le faisceau laser module en frequence ou par detection du signal directement par comptage. Cette derniere methode est une premiere sur ce type d'instrument et son principal interet a ete d'obtenir une meilleure mesure de l'elargissement de raie. Nous sommes parvenus a mettre clairement en evidence l'elargissement de raie avec la puissance laser en utilisant la methode de detection par comptage direct. La fluorescence induite par

  17. Caractérisation des effets de l'implantation ionique dans les alliages super-élastiques nickel titane par diffraction des rayons X

    NASA Astrophysics Data System (ADS)

    Pelletier, H.; Muller, D.; Grob, J. J.; Mille, P.; Cornet, A.

    2002-07-01

    the specific properties (shape memory effect and super-elasticity) of NiTi alloys have provided the enabling technology for many groundbreaking applications in the medical and dentistry industries. These applications include everything from the surgical tools to permanent implants. Super-elastic NiTi alloys take advantage of a stress induced martensitic transformation to achieve incredible amounts of flexibility. This last property represents the most interesting aspect of such alloys for restoration procedures. However, recent instrumentation tests have shown brittle rupture of endodontic instruments inside the tooth during preparation of dental root channels.To improve the mechanical properties of NiTi endodontic instruments, argon, nitrogen and boron implantations at different energies and at fixed dose (1.10^{17} at.cm^{-2}) have been used. In this paper, we have investigated the effects on NiTi microstructure, especially the crystalline to amorphous transition induced by ion bombardment, using Grazing Incidence X-ray Diffraction (GIXRD). Nano-indentation tests have also been performed to determine hardness H and elastic modulus E of implanted surfaces as a function of ion species and energy. Le but de cette d'étude est de caractériser les effets de l'implantation ionique sur la microstructure d'un alliage Nickel Titane à l'aide de la diffraction des rayons X en incidence rasante. Nous avons réalisé différents types d'implantation en faisant varier l'espèce implantée (bore, azote, argon) ainsi que l'énergie d'implantation, pour des doses d'implantation de l'ordre de 1.10^{17} at.cm^{-2}. Les résultats des mesures de diffraction sous différents angles d'incidence (0{,}5^circ leq α_ileq 6^circ) ont été corrélés avec les différents profils d'implantation simulés. Des tests de nanoindentation ainsi que des mesures de RBS ont été également réalisés. Après implantation, on observe la formation d'une couche amorphe, conduisant à une

  18. Influence de la microstructure sur la stabilité électrique des thermistances C.T.N.

    NASA Astrophysics Data System (ADS)

    Rousset, A.; Lagrange, A.; Brieu, M.; Couderc, J. J.; Legros, R.

    1993-04-01

    Thermistors with negative temperature coefficient (N.T.C.) made of spinel structure transition metal manganites usually display ageing phenomena under thermal constraint. The resistance drift depends on the composition, structure (cubic or tetragonal) and thermal treatments. Relationships between thermal treatments and ageing of the ceramics have been studied by electron microscopy. Usually the grains of slowly cooled ceramics are free from lattice defects such as dislocation or planar defects. Otherwise quenched ceramics are always multiphase with a high density of dislocations and planar defects. These two dimensional defects result in lamellar (microtwins or exsolutions) or very thin “tweed” structures. Since ageing is believed to be correlated to atomic diffusion in the spinel lattice, these intergranular defects could act as barriers against ion mobility thus explaining the better thermal stability of quenched ceramics. Les thermistances CTN constituées de manganites de métaux de transition présentent généralement des phénomènes de vieillissement sous contrainte thermique. Les dérives observées dépendent de la composition, de la structure (cubique ou quadratique), des traitements thermiques subis par la céramique. Afin de tenter d'expliquer les corrélations entre l'influence des traitements thermiques et les phénomènes de vieillissement, nous avons procédé à une étude en microscopie électronique. D'une façon générale, les céramiques refroidies très lentement présentent des grains exempts de dislocations ou de défauts-plans. Au contraire, les céramiques trempées sont toujours polyphasées et présentent des densités importantes de dislocations et de défauts-plans. Ces défauts bidimensionnels se manifestent sous forme de lamelles soit d'épaisseur comprise entre 30 et 600 nm (micromacles ou exsolutions), soit d'épaisseur beaucoup plus faible (structure “ tweed ”). Les phénomènes de vieillissement semblant liés à des

  19. 33 CFR 117.439 - Des Allemands Bayou.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Des Allemands Bayou. 117.439... DRAWBRIDGE OPERATION REGULATIONS Specific Requirements Louisiana § 117.439 Des Allemands Bayou. (a) The draw of the S631 bridge, mile 13.9 at Des Allemands, shall open on signal if at least four hours notice...

  20. 33 CFR 117.439 - Des Allemands Bayou.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Des Allemands Bayou. 117.439... DRAWBRIDGE OPERATION REGULATIONS Specific Requirements Louisiana § 117.439 Des Allemands Bayou. (a) The draw of the S631 bridge, mile 13.9 at Des Allemands, shall open on signal if at least four hours notice...

  1. 75 FR 63714 - Drawbridge Operation Regulation; Des Allemands Bayou, LA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-18

    ... SECURITY Coast Guard 33 CFR Part 117 Drawbridge Operation Regulation; Des Allemands Bayou, LA AGENCY: Coast... Burlington Northern Santa Fe Railway swing bridge across Des Allemands Bayou, mile 14.0, in St. Charles and... INFORMATION: The Burlington Northern Santa Fe Railway swing span drawbridge across Bayou Des Allemands,...

  2. Statutes of limitations: the special problem of DES suits.

    PubMed

    Feigin, C A

    1981-01-01

    In 1971, medical studies determined that DES causes a rare type of vaginal cancer in a small number of daughters of mothers who took DES during pregnancy. Subsequently, medical studies determined that exposure to DES can cause other vaginal abnormalities in the daughters, some of which may be precancerous. As a result of these discoveries, many lawsuits have been filed by these daughters against DES manufacturers. Many DES suits may be barred by statutes of limitations, both because the number of years between the daughters' exposure to DES in utero and the discovery that DES can cause injuries exceeds the statutory period, and because the cancer or other injuries caused by DES may not develop for many additional years. This Note discusses two methods that DES plaintiffs may be able to use to overcome the potential statutes of limitations bar: the discovery rule, and state provisions which toll the statute of limitations for minors. The Note contends that courts should apply an expanded discovery rule to DES suits to avoid the unfair result of barring a claim before the plaintiff could have known that she had a cause of action. In addition, the Note argues that the injury which causes the statute of limitations to begin to run in DES suits should not be rigidly defined. Finally, the Note urges that courts allow eligible DES plaintiffs to take advantage of applicable state provisions that toll the statute of limitations for minors.

  3. Potentialités des lasers à fibre dans la génération de rayonnement cohérent UV

    NASA Astrophysics Data System (ADS)

    Martel, G.; Hideur, A.; Ortaç, B.; Lecourt, J.-B.; Chédot, C.; Brunel, M.; Chéron, B.; Limpert, J.; Tunnermann, T.; Grelu, Ph.; Gicquel-Guézo, M.; Labbé, C.; Loualiche, S.; Roussignol, Ph.; Sanchez, F.; Leblond, H.

    2006-12-01

    Le premier laser à fibre dopé aux ions de terres rares fonctionna au tout début des années 60. Il fournissait quelques milliwatts autour de 1 μm. Les décades suivantes virent très peu d'améliorations tant du côté des laboratoires que du point de vue industriel. La dernière décennie (1995/2005) vit se concrétiser la seconde révolution des lasers à fibres. Déjà kilowatt en continu, ils atteignent désormais les 1013 watts/cm2 avec des impulsions de la centaine de femtoseconde. Lors de cette présentation nous passerons en revue les potentialités des lasers à fibre. Nous décrirons les verrous technologiques qui ont été levés ces dix dernières années pour les régimes CW mais aussi femtosecondes. Nous montrerons également comment la prochaine génération de fibres optiques actuellement en développement permettra d'offrir des sources stables et de très haute puissance pour l'avenir proche.

  4. ION SOURCE

    DOEpatents

    Bell, W.A. Jr.; Love, L.O.; Prater, W.K.

    1958-01-28

    An ion source is presented capable of producing ions of elements which vaporize only at exceedingly high temperatures, i.e.,--1500 degrees to 3000 deg C. The ion source utilizes beams of electrons focused into a first chamber housing the material to be ionized to heat the material and thereby cause it to vaporize. An adjacent second chamber receives the vaporized material through an interconnecting passage, and ionization of the vaporized material occurs in this chamber. The ionization action is produced by an arc discharge sustained between a second clectron emitting filament and the walls of the chamber which are at different potentials. The resultant ionized material egresses from a passageway in the second chamber. Using this device, materials which in the past could not be processed in mass spectometers may be satisfactorily ionized for such applications.

  5. Note des Éditeurs scientifiques

    NASA Astrophysics Data System (ADS)

    Averbuch, P.

    Cette série d'articles est une revue de résultats expérimentaux sur différents "fluides" moléculaires, dans lesquels la cohésion est due à des forces de Van der Waals et à des liaisons hydrogène, l'eau étant un de ces fluides. Ces résultats sont présentés de façon à justifier expérimentalement un modèle original, non extensif, des propriétés de ces fluides, et l'ensemble se présente sous la forme de trois articles décrivant le modèle, suivis chacun par un article le comparant aux résultats expérimentaux publiés par de nombreux auteurs. Le caractère non extensif des propriétés physiques des fluides est choquant, contraire à beaucoup d'idées établies, il semble n'avoir en sa faveur qu'un argument, la comparaison avec un nombre de résultats expérimentaux assez grand pour que l'effet du hasard soit difficilement soupçonnable. En particulier, les écarts entre des résultats de mesures faits par des auteurs différents dans des conditions différentes sont expliqués, le sérieux et la compétence des différents expérimentateurs ne sont plus mis en doute : mais l'interprétation de ces résultats avec un modèle extensif non adapté est seule mise en cause. Les modèles extensifs étant utilisés systématiquement, au delà des expériences de physiciens, dans les calculs d'ingénieurs, et dans la modélisation d'appareils qui fonctionnent et de phénomènes naturels observés par tout le monde, il fallait expliquer pourquoi on pouvait renoncer à l'extensivité. Les raisons du succès pratique des modèles extensifs sont données, d'abord dans le cas des nématiques, puis dans celui des liquides ordinaires, et c'est ce qui rend l'ensemble cohérent, tant avec les mesures physiques fines qu'avec les observations quotidiennes. Il n'en reste pas moins que si l'interprétation donnée dans cette série d'articles est généralisable, une justification théorique du modèle utilisé devient nécessaire. Pour ce qui est des propriétés d

  6. Effets de L'anisotropie Cristalline et du Desordre Controle Sur les Proprietes Optiques et Phononiques des Composes Semiconducteurs ZIRCONIUM(1-X) Hafnium(x) SOUFRE(3)

    NASA Astrophysics Data System (ADS)

    Ait-Ouali, Abderrahmane

    Dans ce travail, nous presentons l'etude de l'effet de l'anisotropie cristalline et du desordre substitutionnel controle sur les proprietes electroniques et vibrationnelles des composes semiconducteurs Zr_{rm 1-x}Hf_{x} S_3. Les proprietes phononiques sont ete etudiees en spectroscopie Raman. Les mesures systematiques des spectres polarises de tous les composes nous ont permis d'identifier tous les phonons predits par la theorie des groupes et de suivre l'evolution de leur frequence avec la concentration de hafnium. L'analyse plus approfondie par un procede de lissage des spectres nous a permis detudier l'effet du desordre controle sur la largeur des modes phononiques. Les resultats de cette analyse ont ete confrontes aux predictions d'un modele developpe pour une chai ne diatomique desordonnee et ameliore suite a nos observations experimentales. La forme en cloche predite par ce dernier pour la variation de la largeur du mode optique de la chai ne est observee pour trois phonons de symetrie Bg. L'accord est excellent pour X > 0.5 pour deux des trois modes et ce, sans aucun parametre ajustable. Cette etude nous a permis, d'une part, de conclure que les modes Bg se comportent comme s'ils etaient sur une chai ne isolee et que, par consequent, les deux chai nes composant la cellule unite de nos cristaux sont tres faiblement liees et, d'autre part, de confirmer la symetrie des modes telle que deduite des spectres polarises. Les proprietes electroniques du ZrS_3 ont ete etudiees par des mesures polarisees du coefficient d'absorption pres de son gap indirect. L'evolution des spectres avec la temperature nous a permis d'identifier deux gaps paralleles differents et un gap perpendiculaire confirmant ainsi le modele de la structure de bande base sur les etats electroniques moleculaires de l'ion (S _2)^2. L'analyse detaillee des differentes structures du coefficient d'absorption indique clairement un caractere bidimensionnel du gap indirect. L'effet du desordre

  7. Etude theorique et experimentale des evaporateurs de dioxyde de carbone operant dans des conditions de givrage

    NASA Astrophysics Data System (ADS)

    Bendaoud, Adlane Larbi

    Les evaporateurs de refrigeration sont surtout du type tube a ailettes, appeles serpentins, et fonctionnent dans l'une des conditions suivantes: seche, humide ou avec formation de givre. Il a ete demontre que la formation du givre sur la paroi exterieure de l'echangeur engendre une surconsommation energetique a cause des operations de degivrage puisque 15 a 20% seulement de la chaleur produite sert au degivrage tandis que le reste est dissipee dans l'environnement [1]. Avec l'avenement des nouveaux refrigerants, moins nocifs envers l'environnement, l'industrie du froid se trouve penalisee du fait que peu ou pas de composantes mecaniques (compresseur, pompe, echangeur...etc.) adaptees sont disponibles [3]. Il s'agit pour la communaute des frigoristes de combler ce retard technologique en redeveloppant ces composantes mecaniques afin qu'elles soient adaptees aux nouveaux refrigerants. Dans cette optique, et afin de mieux comprendre le comportement thermique des evaporateurs au CO2 fonctionnant dans des conditions seches, qu'un groupe de chercheurs du CanmetENERGIE avaient lance, en 2000, un programme de R & D. Dans le cadre de programme un outil de simulation des evaporateurs au CO2 a ete developpe et un banc d'essai contenant une boucle secondaire de refrigeration utilisant le CO2 comme refrigerant a ete construit. Comme continuite de ce travail de recherche, en 2006 ce meme groupe de recherche a lance un nouveau projet qui consiste a faire une etude theorique et experimentale des evaporateurs au CO2 operants dans des conditions de givrage. Et, c'est exactement dans le cadre de ce projet que se positionne ce travail de these. Ce travail de recherche a ete entrepris pour mieux comprendre le comportement thermique et hydrodynamique des serpentins fonctionnant dans des conditions de givrage, l'effet des circuits de refrigerant ainsi que celui des parametres geometriques et d'operation. Pour cela, un travail theorique supporte par une etude experimentale a ete effectue

  8. The "Conservatoire National des Arts et Metiers"

    ERIC Educational Resources Information Center

    Kuhn, Gerard

    2004-01-01

    The overall mission of the Conservatoire national des arts et metiers--(CNAM) [National Conservatory of Industrial Arts and Trades] is outlined. One of its centers, the "Centre national de l'entrepreneuriat"--(CNE) [National Center for Entrepreneurship] is described in greater detail. In particular, this center offers various services, notably…

  9. Fiabilité des structures mécaniques adaptatives: effet de la panne des actionneurs ou des capteurs sur la stabilité

    NASA Astrophysics Data System (ADS)

    Fall, H.; Charon, W.; Kouta, R.

    2002-12-01

    Ces dernières décennies, des activités significatives dans le monde étaient dirigées autour du contrôle actif. Le but de ces recherches était essentiellement d'améliorer les performances, la fiabilité et la sécurité des systèmes. Notamment dans le cas des structures soumises à des vibrations aléatoires. D'importants travaux ont été consacré à l'utilisation des “matériaux intelligents” comme capteurs et actionneurs. Cette article propose l'analyse de la fiabilité des systèmes mécaniques en étudiant les pannes des actionneurs ou des capteurs. L'effet de ces pannes sur la stabilité et la performance du système y est démontré. Les méthodologies de conception y sont rappelées. Des exemples numériques sont fournis à travers le contrôle d'un panneau sous chargement dynamique pour illustrer la méthode proposée.

  10. ION PUMP

    DOEpatents

    Milleron, N.

    1961-01-01

    An ion pump and pumping method are given for low vacuum pressures in which gases introduced into a pumping cavity are ionized and thereafter directed and accelerated into a quantity of liquid gettering metal where they are absorbed. In the preferred embodiment the metal is disposed as a liquid pool upon one electrode of a Phillips ion gauge type pump. Means are provided for continuously and remotely withdrawing and degassing the gettering metal. The liquid gettering metal may be heated if desired, although various combinations of gallium, indium, tin, bismuth, and lead, the preferred metals, have very low melting points. A background pressure of evaporated gettering metal may be provided by means of a resistance heated refractory metal wick protruding from the surface of the pcol of gettering metal.

  11. Ion Interferometry

    NASA Astrophysics Data System (ADS)

    Erickson, Christopher J.; Lyon, Mary; Bennett, Aaron; Troxel, Daylin; Blaser, Kelvin J.; Harper, Stuart; Durfee, Dallin S.

    2010-03-01

    We report on the progress of an ion interferometer based on a laser-cooled ^87Sr^+ beam which will be split and recombined using stimulated Raman transitions. This device will be used to implement an extremely precise electromagnetic field sensor. Design considerations and instrumentation development will be discussed. Possible practical and fundamental applications, including deviations from Coulomb's inverse-square law and the search for a possible photon rest mass, will be discussed.

  12. Controllable Laser Ion Acceleration

    NASA Astrophysics Data System (ADS)

    Kawata, S.; Kamiyama, D.; Ohtake, Y.; Takano, M.; Barada, D.; Kong, Q.; Wang, P. X.; Gu, Y. J.; Wang, W. M.; Limpouch, J.; Andreev, A.; Bulanov, S. V.; Sheng, Z. M.; Klimo, O.; Psikal, J.; Ma, Y. Y.; Li, X. F.; Yu, Q. S.

    2016-02-01

    In this paper a future laser ion accelerator is discussed to make the laser-based ion accelerator compact and controllable. Especially a collimation device is focused in this paper. The future laser ion accelerator should have an ion source, ion collimators, ion beam bunchers, and ion post acceleration devices [Laser Therapy 22, 103(2013)]: the ion particle energy and the ion energy spectrum are controlled to meet requirements for a future compact laser ion accelerator for ion cancer therapy or for other purposes. The energy efficiency from the laser to ions is improved by using a solid target with a fine sub-wavelength structure or a near-critical density gas plasma. The ion beam collimation is performed by holes behind the solid target or a multi-layered solid target. The control of the ion energy spectrum and the ion particle energy, and the ion beam bunching would be successfully realized by a multistage laser-target interaction.

  13. Highly charged ion secondary ion mass spectroscopy

    DOEpatents

    Hamza, Alex V.; Schenkel, Thomas; Barnes, Alan V.; Schneider, Dieter H.

    2001-01-01

    A secondary ion mass spectrometer using slow, highly charged ions produced in an electron beam ion trap permits ultra-sensitive surface analysis and high spatial resolution simultaneously. The spectrometer comprises an ion source producing a primary ion beam of highly charged ions that are directed at a target surface, a mass analyzer, and a microchannel plate detector of secondary ions that are sputtered from the target surface after interaction with the primary beam. The unusually high secondary ion yield permits the use of coincidence counting, in which the secondary ion stops are detected in coincidence with a particular secondary ion. The association of specific molecular species can be correlated. The unique multiple secondary nature of the highly charged ion interaction enables this new analytical technique.

  14. Instrumentation: Ion Chromatography.

    ERIC Educational Resources Information Center

    Fritz, James S.

    1987-01-01

    Discusses the importance of ion chromatography in separating and measuring anions. The principles of ion exchange are presented, along with some applications of ion chromatography in industry. Ion chromatography systems are described, as well as ion pair and ion exclusion chromatography, column packings, detectors, and programming. (TW)

  15. Hydrated Ions: From Individual Ions to Ion Pairs to Ion Clusters.

    PubMed

    Chen, Houyang; Ruckenstein, Eli

    2015-10-01

    The structure of hydrated ions plays a central role in chemical and biological sciences. In the present paper, five ions, namely, Na(+), K(+), Mg(2+), Ca(2+) and Cl(-), are examined using molecular dynamics simulations. In addition to hydrated individual ions and ion pairs identified previously, hydrated ion clusters containing 3, 4, 5, or more ions are identified in the present paper. The dependence of hydration numbers and mole fractions of individual ions, ion pairs, and larger ion clusters on the electrolyte concentration is determined. As the electrolyte concentration increases, the mole fraction of hydrated individual ions decreases, and the mole fraction of hydrated larger ion clusters increases. The results also reveal that the hydrogen bonding numbers of the H2O molecules of the first hydration shells of individual ions, ion pairs, and larger ion clusters are insensitive to the electrolyte concentration, but sensitive to the nature and conformation of ions. PMID:26358093

  16. Hydrated Ions: From Individual Ions to Ion Pairs to Ion Clusters.

    PubMed

    Chen, Houyang; Ruckenstein, Eli

    2015-10-01

    The structure of hydrated ions plays a central role in chemical and biological sciences. In the present paper, five ions, namely, Na(+), K(+), Mg(2+), Ca(2+) and Cl(-), are examined using molecular dynamics simulations. In addition to hydrated individual ions and ion pairs identified previously, hydrated ion clusters containing 3, 4, 5, or more ions are identified in the present paper. The dependence of hydration numbers and mole fractions of individual ions, ion pairs, and larger ion clusters on the electrolyte concentration is determined. As the electrolyte concentration increases, the mole fraction of hydrated individual ions decreases, and the mole fraction of hydrated larger ion clusters increases. The results also reveal that the hydrogen bonding numbers of the H2O molecules of the first hydration shells of individual ions, ion pairs, and larger ion clusters are insensitive to the electrolyte concentration, but sensitive to the nature and conformation of ions.

  17. Etude du processus de changement vecu par des familles ayant decide d'adopter volontairement des comportements d'attenuation des changements climatiques

    NASA Astrophysics Data System (ADS)

    Leger, Michel T.

    Les activites humaines energivores telles l'utilisation intensive de l'automobile, la surconsommation de biens et l'usage excessif d'electricite contribuent aux changements climatiques et autres problemes environnementaux. Bien que plusieurs recherches rapportent que l'etre humain est de plus en plus conscient de ses impacts sur le climat de la planete, ces memes recherches indiquent qu'en general, les gens continuent a se comporter de facon non ecologique. Que ce soit a l'ecole ou dans la communaute, plusieurs chercheurs en education relative a l'environnement estiment qu'une personne bien intentionnee est capable d'adopter des comportements plus respectueux de l'environnement. Le but de cette these etait de comprendre le processus d'integration de comportements d'attenuation des changements climatiques dans des familles. A cette fin, nous nous sommes fixe deux objectifs : 1) decrire les competences et les procedes qui favorisent l'adoption de comportements d'attenuation des changements climatiques dans des familles et 2) decrire les facteurs et les dynamiques familiales qui facilitent et limitent l'adoption de comportements d'attenuation des changements climatiques dans des familles. Des familles ont ete invitees a essayer des comportements personnels et collectifs d'attenuation des changements climatiques de sorte a integrer des modes de vie plus ecologiques. Sur une periode de huit mois, nous avons suivi leur experience de changement afin de mieux comprendre comment se produit le processus de changement dans des familles qui decident volontairement d'adopter des comportements d'attenuation des changements climatiques. Apres leur avoir fourni quelques connaissances de base sur les changements climatiques, nous avons observe le vecu de changement des familles durant huit mois d'essais a l'aide de journaux reflexifs, d'entretiens d'explicitation et du journal du chercheur. La these comporte trois articles scientifiques. Dans le premier article, nous presentons une

  18. Elaboration de nouvelles approches micromecaniques pour l'optimisation des performances mecaniques des materiaux heterogenes

    NASA Astrophysics Data System (ADS)

    Aboutajeddine, Ahmed

    Les modeles micromecaniques de transition d'echelles qui permettent de determiner les proprietes effectives des materiaux heterogenes a partir de la microstructure sont consideres dans ce travail. L'objectif est la prise en compte de la presence d'une interphase entre la matrice et le renforcement dans les modeles micromecaniques classiques, de meme que la reconsideration des approximations de base de ces modeles, afin de traiter les materiaux multiphasiques. Un nouveau modele micromecanique est alors propose pour tenir compte de la presence d'une interphase elastique mince lors de la determination des proprietes effectives. Ce modele a ete construit grace a l'apport de l'equation integrale, des operateurs interfaciaux de Hill et de la methode de Mori-Tanaka. Les expressions obtenues pour les modules globaux et les champs dans l'enrobage sont de nature analytique. L'approximation de base de ce modele est amelioree par la suite dans un nouveau modele qui s'interesse aux inclusions enrobees avec un enrobage mince ou epais. La resolution utilisee s'appuie sur une double homogeneisation realisee au niveau de l'inclusion enrobee et du materiau. Cette nouvelle demarche, permettra d'apprehender completement les implications des approximations de la modelisation. Les resultats obtenus sont exploites par la suite dans la solution de l'assemblage de Hashin. Ainsi, plusieurs modeles micromecaniques classiques d'origines differentes se voient unifier et rattacher, dans ce travail, a la representation geometrique de Hashin. En plus de pouvoir apprecier completement la pertinence de l'approximation de chaque modele dans cette vision unique, l'extension correcte de ces modeles aux materiaux multiphasiques est rendue possible. Plusieurs modeles analytiques et explicites sont alors proposee suivant des solutions de differents ordres de l'assemblage de Hashin. L'un des modeles explicite apparait comme une correction directe du modele de Mori-Tanaka, dans les cas ou celui ci echoue a

  19. Ion detector

    DOEpatents

    Tullis, Andrew M.

    1987-01-01

    An improved ion detector device of the ionization detection device chamber ype comprises an ionization chamber having a central electrode therein surrounded by a cylindrical electrode member within the chamber with a collar frictionally fitted around at least one of the electrodes. The collar has electrical contact means carried in an annular groove in an inner bore of the collar to contact the outer surface of the electrode to provide electrical contact between an external terminal and the electrode without the need to solder leads to the electrode.

  20. Evidence for Sequence Scrambling in Collision-Induced Dissociation of y-Type Fragment Ions

    NASA Astrophysics Data System (ADS)

    Miladi, Mahsan; Harper, Brett; Solouki, Touradj

    2013-11-01

    Sequence scrambling from y-type fragment ions has not been previously reported. In a study designed to probe structural variations among b-type fragment ions, it was noted that y fragment ions might also yield sequence-scrambled ions. In this study, we examined the possibility and extent of sequence-scrambled fragment ion generation from collision-induced dissociation (CID) of y-type ions from four peptides (all containing basic residues near the C-terminus) including: AAAAH AA-NH2 (where " A" denotes carbon thirteen (13C1) isotope on the alanine carbonyl group), des-acetylated-α-melanocyte (SYSMEHFRWGKPV-NH2), angiotensin II antipeptide (EGVYVHPV), and glu-fibrinopeptide b (EGVNDNEEGFFSAR). We investigated fragmentation patterns of 32 y-type fragment ions, including y fragment ions with different charge states (+1 to +3) and sizes (3 to 12 amino acids). Sequence-scrambled fragment ions were observed from ~50 % (16 out of 32) of the studied y-type ions. However, observed sequence-scrambled ions had low relative intensities from ~0.1 % to a maximum of ~12 %. We present and discuss potential mechanisms for generation of sequence-scrambled fragment ions. To the best of our knowledge, results on y fragment dissociation presented here provide the first experimental evidence for generation of sequence-scrambled fragments from CID of y ions through intermediate cyclic "b-type" ions.

  1. Improved ion source

    DOEpatents

    Leung, K.N.; Ehlers, K.W.

    1982-05-04

    A magnetic filter for an ion source reduces the production of undesired ion species and improves the ion beam quality. High-energy ionizing electrons are confined by the magnetic filter to an ion source region, where the high-energy electrons ionize gas molecules. One embodiment of the magnetic filter uses permanent magnets oriented to establish a magnetic field transverse to the direction of travel of ions from the ion source region to the ion extraction region. In another embodiment, low energy 16 eV electrons are injected into the ion source to dissociate gas molecules and undesired ion species into desired ion species,

  2. Étude des déplacements induits par des précipités dans des alliages à base de cuivre

    NASA Astrophysics Data System (ADS)

    Guillon, I.; Servant, C.; Lyon, O.

    2004-11-01

    Cette étude a pour but de mieux comprendre les premières étapes des phénomènes se produisant lors de la formation de nanoprécipités. En effet, la microstructure des alliages conditionne leurs propriétés mécaniques, et donc l'emploi de ces matériaux. Alors que l'anisotropie des déformations élastiques permet d'expliquer la morphologie des précipités formés lors des traitements thermiques de revenu, peu d'études se sont attachées à les déterminer expérimentalement. Mots clés : transformations de phases, diffusion/diffraction, synchrotron, alliages à base Cu, déplacements

  3. Ion parking during ion/ion reactions in electrodynamic ion traps.

    PubMed

    McLuckey, Scott A; Reid, Gavin E; Wells, J Mitchell

    2002-01-15

    Under appropriate ion density conditions, it is possible to selectively inhibit rates of ion/ion reactions in a quadrupole ion trap via the application of oscillatory voltages to one or more electrodes of the ion trap. The phenomenon is demonstrated using dipolar resonance excitation applied to the end-cap electrodes of a three-dimensional quadrupole ion trap. The application of a resonance excitation voltage tuned to inhibit the ion/ion reaction rate of a specific range of ion mass-to-charge ratios is referred to as "ion parking". The bases for rate inhibition are (i) an increase in the relative velocity of the ion/ion reaction pair, which reduces the cross section for ion/ion capture and, at least in some cases, (ii) reduction in the time of physical overlap of positively charged and negatively charged ion clouds. The efficiency and specificity of the ion parking experiment is highly dependent upon ion densities, trapping conditions, ion charge states, and resonance excitation conditions. The ion parking experiment is illustrated herein along with applications to the concentration of ions originally present over a range of charge states into a selected charge state and in the selection of a particular ion from a set of ions derived from a simple protein mixture.

  4. TRANSPLANTATION EN MASSE DES ORGANES ABDOMINAUX

    PubMed Central

    STARZL, T.

    2010-01-01

    Les transplantations multi-organes, comprenant les blocs foie-duodénum-pancréas, foie-estomac-duodénum-pancréas, et foie-intestin sont réalisées avec un succés croissant Ces techniques et leurs combinaisons variées de transplantation monobloc ne sont pas de pratique courante. Les techniques de prélévement, de conservation et de soins post-opératoires sont décrites pour la transplantation multi-organes compléte ainsi que pour les variantes incomplétes. Le probléme particulier à ce type de transplantation est celui de la transplantation intestinale, c’est-à-dire la transplantation d’un organe à composante lymphoréticulaire complexe ce qui peut provoquer un syndrome greffon contre hôte. Par erreur de conception, et un peu par esprit de systéme, les efforts par le passé étaient dirigés sur la modification et la destruction des systémes lymphoréticulaires grâce au traitement préalable du donneur ou des organes transplantés, par médicaments, radiation ou autres moyens. Actuellement, I’idée directrice est de garder intacte les systémes lymphoréticulaires qui deviennent alors le site d’une circulation à double sens aprés transplantation. Avec la puissante immunodépression que fournit le FK 506, les cellules lymphoréticulaires du donneur peuvent circuler chez le receveur sans créer de syndrome du greffon contre hôte clinique et les cellules de la greffe s’assimilent à celles du receveur (chimérisme local) sans provoquer de rejet. Même si I’on évite le rejet ou le syndrome greffon contre hôte, il existe, à côté de ces entités, des relations métaboliques entre les organes greffés ainsi qu’entre les organes greffés et les viscéres du receveur laissés en place, qui peuvent influencer I’avenir soit des organes greffés, soit des organes laissés en place. Parmi les échanges métaboliques les mieux connus actuellement, il y a les facteurs splanchniques hépatotrophes endogénes, dont I’insuline est la mieux

  5. ION GUN

    DOEpatents

    Dandl, R.A.

    1961-10-24

    An ion gun is described for the production of an electrically neutral ionized plasma. The ion gun comprises an anode and a cathode mounted in concentric relationship with a narrow annulus between. The facing surfaces of the rear portions of the anode and cathode are recessed to form an annular manifold. Positioned within this manifold is an annular intermediate electrode aligned with the an nulus between the anode and cathode. Gas is fed to the manifold and an arc discharge is established between the anode and cathode. The gas is then withdrawn from the manifold through the annulus between the anode and cathode by a pressure differential. The gas is then ionized by the arc discharge across the annulus. The ionized gas is withdrawn from the annulus by the combined effects of the pressure differential and a collimating magnetic field. In a 3000 gauss magnetic field, an arc voltage of 1800 volts, and an arc current of 0.2 amp, a plasma of about 3 x 10/sup 11/ particles/cc is obtained. (AEC)

  6. A Magellanic origin of the DES dwarfs

    NASA Astrophysics Data System (ADS)

    Jethwa, P.; Erkal, D.; Belokurov, V.

    2016-09-01

    We establish the connection between the Magellanic Clouds (MCs) and the dwarf galaxy candidates discovered in the Dark Energy Survey (DES) by building a dynamical model of the MC satellite populations, based on an extensive suite of tailor-made numerical simulations. Our model takes into account the response of the Galaxy to the MCs infall, the dynamical friction experienced by the MCs and the disruption of the MC satellites by their hosts. The simulation suite samples over the uncertainties in the MC's proper motions, the masses of the MW and the Clouds themselves, and allows for flexibility in the intrinsic volume density distribution of the MC satellites. As a result, we can accurately reproduce the DES satellites' observed positions and kinematics. Assuming that Milky Way (MW) dwarfs follow the distribution of sub-haloes in Λ cold dark matter, we further demonstrate that, of 14 observed satellites, the MW halo contributes fewer than 4(8) of these with 68(95) per cent confidence and that 7(12) DES dwarfs have probabilities greater than 0.7(0.5) of belonging to the Large Magellanic Cloud (LMC). Marginalizing over the entire suite, we constrain the number of Magellanic satellites in the range -7 < MV < -1 which exceed the DES surface brightness threshold at ˜70, and the mass of the LMC around 1011 M⊙. The data also strongly support a first-infall scenario for the LMC. Finally, we give predictions for the line-of-sight velocities and the proper motions of the satellites discovered in the vicinity of the LMC.

  7. Peste des petits ruminants in Arabian wildlife.

    PubMed

    Kinne, J; Kreutzer, R; Kreutzer, M; Wernery, U; Wohlsein, P

    2010-08-01

    Recurrence of peste des petits ruminants (PPR) was diagnosed in the United Arabian Emirates in several wild ruminants confirmed by morphological, immunohistochemical, serological and molecular findings. Phylogenetic analysis revealed that the virus strain belongs to lineage IV, which is different to some previously isolated PPR strains from the Arabian Peninsula. This study shows that wild ruminants may play an important epidemiological role as virus source for domestic small ruminants.

  8. Inhomogeneites dans le Vent des Etoiles Wolf-Rayet

    NASA Astrophysics Data System (ADS)

    Robert, Carmelle

    1992-01-01

    Des mesures spectroscopiques effectuees avec un haut rapport signal sur bruit et une bonne resolution ont demontre l'existence de regions perturbees en mouvement dans le vent d'etoiles Wolf-Rayet (WR). L'echantillon d'objets etudies ici comprend 9 etoiles WR couvrant differents sous-types WN et WC. De nombreuses petites structures variables superposees au profil des raies d'emission formees dans le vent stellaire signalent la presence des perturbations. L'etude des variations globales des raies et l'examen des micro-structures individuelles ont permis de decrire plusieurs caracteristiques des perturbations. Entre autres, on observe des correlations significatives entre le niveau de variabilite des raies et certains parametres des etoiles qui confirment que le phenomene de variabilite est intrinseque au vent stellaire. En comparant les changements des vitesses radiales et des largeurs equivalentes des differentes raies d'une meme etoile, on conclut que les regions perturbees ont une etendue finie par rapport a l'enveloppe des etoiles. On peut facilement suivre les structures individuelles sur une periode de temps couvrant ~eq8 heures (et peut etre meme 24 heures) avant qu'elles ne disparaissent. Durant ce temps les structures se deplacent en s'eloignant du centre de la raie. A partir des differents comportements notes lors de l'analyse des variations globales et lors de l'examen des structures individuelles, on propose de representer les perturbations par un modele d'inhomogeneites discretes en expansion dans le vent. On suppose simplement que les inhomogeneites emettent comme le vent global (et absorbent aussi si le vent global montre un profil P Cyg). La superposition du graphique de l'acceleration radiale moyenne des inhomogeneites de WR140 en fonction de leur vitesse radiale et du modele theorique d'inhomogeneites qui suivent la loi generale de vitesse donne un taux d'acceleration lent, avec beta >= 3 pour les inhomogeneites de cette etoile. On obtient, entre

  9. Dermatomyosite et panniculite: place des immunoglobulines

    PubMed Central

    Abdelhafidh, Nadia Ben; Toujeni, Sana; Kefi, Asma; Bousetta, Najeh; Sayhi, Sameh; Gharsallah, Imen; Othmani, Salah

    2016-01-01

    La panniculite est une maladie inflammatoire du tissu adipeux sous-cutané rarement associée à la dermatomyosite. Elle peut survenir avant, après ou en même temps que l'atteinte musculaire. Dans la plupart des cas, l’évolution de la panniculite et des autres atteintes de la dermatomyosite est favorable sous traitement corticoïde et/ou immunosuppresseur. Nous rapportons le cas d'une patiente âgée de 48 ans ayant présenté des lésions de panniculite précédant de 2 mois les signes musculaires. L'atteinte cutanée était résistante au traitement corticoïde associés aux immunosuppresseurs ce qui a nécessité le recours au traitement par Immunoglobulines polyvalentes permettant ainsi une amélioration à la fois de l'atteinte cutanée et musculaire. PMID:27516827

  10. Profil anthropometrique des enfants scolarises tananariviens

    PubMed Central

    Razafimanantsoa, Fetralinjiva; Razafindramaro, Notahiana; Raherimandimby, Hasina; Robinson, Annick; RakotoAlson, Olivat; Rasamindrakotroka, Andry

    2013-01-01

    Les enfants tananariviens sont en état de malnutrition chronique. Notre objectif est d’évaluer l'indice de masse corporelle (IMC) pour estimer les enfants apparemment "sains". Une enquête et une mesure de la taille et du poids des enfants scolarisés tananariviens de 6 à 11 ans ont été réalisées. Après leur accord, la taille et l'indice de masse corporelle des 442 enfants tirés au hasard ont été ainsi obtenus. L'analyse de la moyenne de la taille a révélé une différence significative à 8 ans, une différence non évidente sur l'indice de masse corporelle. La comparaison avec les valeurs de référence (OMS 2006) a montré un retard statural de 34% avec une tendance globale à la hausse et un déficit pondéral égal à 5,5% selon le z score. Ainsi, au sein d'une population malnutrie, l'indice de masse corporelle pourrait être utilisé comme un des paramètres à considérer dans l’évaluation de l’état de santé pour classer ces enfants en bonne santé apparente. PMID:24711862

  11. Newtons Universum. Materialien zur Geschichte des Kraftbegriffes.

    NASA Astrophysics Data System (ADS)

    Mit einem Vorwort von E. Seibold und einer Einführung von W. Neuser. This book is a selection of 15 articles published in the journal "Spektrum der Wissenschaft". The original English versions of the papers were first published in "Scientific American". Contents: 1. Impetustheorie und Intuition in der Physik (M. McCloskey). 2. Mittelalterliche Ursprünge der industriellen Revolution (T. S. Reynolds). 3. Leonardo da Vincis Beiträge zur theoretischen Mechanik (V. Foley, W. Soedel). 4. Nikolaus Kopernikus und Tycho Brahe (O. Gingerich). 5. Keplers Entdeckung der ersten beiden Planetengesetze (C. Wilson). 6. Galileis Entdeckung des Fallgesetzes (S. Drake). 7. Galileis Beobachtung des Neptun (S. Drake, C. T. Kowal). 8. Galileo Galilei und der Schatten des Giordano Bruno (L. S. Lerner, E. A. Gosselin). 9. Der Fall Galilei (O. Gingerich). 10. Newtons Apfel und Galileis "Dialog" (S. Drake). 11. Newtons Gravitationsgesetz - aus Formeln wird eine Idee (I. B. Cohen). 12. Christopher Wren: Astronom und Architekt (H. Dorn, R. Mark). 13. Atomismus und Kräfte in der Geschichte (L. Holliday). 14. Ein Elitezirkel vor 200 Jahren: Die Lunar Society von Birmingham (L. Ritchie-Calder). 15. Sadi Carnot: Technik und Theorie der Dampfmaschine (S. S. Wilson).

  12. Sécurité au-delà des mythes et des croyances

    SciTech Connect

    2010-06-24

    Présentation orale en français, support visuel en français et en anglais. La pire des failles de sécurité est l'impression de sécurité. Le décalage entre la compréhension que l’on a des technologies utilisées, et leurs potentiels réels, ainsi que l'impact potentiellement négatif qu'elles peuvent avoir sur nos vies, n'est pas toujours compris, ou pris en compte par la plupart d'entre-nous. On se contente de nos perceptions pour ne pas avoir à se confronter à la réalité... Alors qu'en est-il vraiment ? En matière de sécurité qui de l'humain ou des technologies a le contrôle ?

  13. Paternité des articles et intérêts concurrents : une analyse des recommandations aux auteurs des journaux traitant de pratique pharmaceutique

    PubMed Central

    Courbon, Ève; Tanguay, Cynthia; Lebel, Denis; Bussières, Jean-François

    2014-01-01

    RÉSUMÉ Contexte : La présence d’auteurs honorifiques et fantômes ainsi que les intérêts concurrents représentent des difficultés bien documentées, liées à la publication d’articles scientifiques. Il existe des lignes directrices encadrant la rédaction et la publication de manuscrits scientifiques, notamment celles de l’International Committee of Medical Journal Editors (ICMJE). Objectifs : L’objectif principal de cette étude descriptive et transversale visait à recenser les instructions portant sur la paternité des articles et les intérêts concurrents provenant des recommandations aux auteurs des journaux traitant de pratique pharmaceutique. L’objectif secondaire visait à déterminer des mesures correctrices pour une paternité des articles plus transparente. Méthode : La recherche a débuté par l’identification des journaux traitant de pratique pharmaceutique. La consultation des instructions aux auteurs des journaux a permis ensuite de recenser les recommandations destinées à éviter les problèmes de paternité des articles et d’intérêts concurrents. Finalement, les membres de l’équipe de recherche se sont consultés afin de définir des mesures correctrices possibles à l’intention des chercheurs. Résultats : Des 232 journaux traitant de pharmacie, 33 ont été définis comme traitant de pratique pharmaceutique. Un total de 24 (73 %) journaux mentionnaient suivre la politique de l’ICMJE, 14 (42 %) demandaient aux auteurs de remplir un formulaire de déclaration d’intérêts concurrents au moment de la soumission de l’article, 17 (52 %) présentaient une définition de la qualité d’auteur et 5 (15 %) demandaient de détailler les contributions de chaque auteur. Une grille de 40 critères a été élaborée pour définir l’attribution du statut d’auteur. Conclusion : Moins de la moitié des journaux demandait aux auteurs de transmettre un formulaire de déclaration des intérêts concurrents au moment de la

  14. Les effets du travail en equipe dans l'apprentissage par projets sur la motivation des etudiantes et des etudiants en formation des ingenieurs

    NASA Astrophysics Data System (ADS)

    Fernandez, Nicolas

    Les representants des secteurs industriels et les, milieux professionnels en Amerique du Nord reprochaient aux universites de former des ingenieurs avec peu d'experience pratique en resolution de problemes et en conception. Quelques programmes de genie ont alors mis en place le travail en equipe dans l'apprentissage par projets. Beaucoup d'ecrits font valoir les benefices de l'apprentissage par projets sur la motivation des etudiants. Or, ces benefices commencent a peine a faire l'objet de recherches visant a produire des donnees probantes a ce sujet. Les travaux sur la motivation en contexte d'apprentissage et les modeles theoriques developpes sont issus d'environnements d'apprentissage marques par l'enseignement magistral. Le modele de la valeur attendue de la tache (Eccles et Wigfield, 1995; Neuville, 2004) et le modele du systeme-groupe (St-Arnaud, 2008) ont ete retenus pour mesurer les effets du travail en equipe dans l'apprentissage par projets sur la motivation. La recherche visait aussi a approfondir et a nuancer la comprehension de la motivation des etudiants universitaires apprenant en contexte innovant. Les sujets constituent des etudiants (n=100) travaillant sur des projets d'integration au cours des trois sessions initiales du programme de genie mecanique d'une universite canadienne. L'analyse de regression multiple revele que les construits de la motivation expliquent un tiers de la variance de l'engagement academique dans la realisation du projet d'integration. Les perceptions de l' "expectancy", de la valeur intrinseque et utilitaire sont les determinants principaux de l'engagement des etudiants. L'analyse de variance multivariee a mesures repetees indique que la motivation des etudiants pour le travail sur les projets d'integration a augmente au cours des trois sessions initiales du parcours de formation. Finalement, malgre l'absence d'interaction significative entre les variables de motivation et de l'equipe, les reponses des sujets indiquent une

  15. Etude des phenomenes dynamiques ultrarapides et des caracteristiques impulsionnelles d'emission terahertz du supraconducteur YBCO

    NASA Astrophysics Data System (ADS)

    Savard, Stephane

    Les premieres etudes d'antennes a base de supraconducteurs a haute temperature critique emettant une impulsion electromagnetique dont le contenu en frequence se situe dans le domaine terahertz remontent a 1996. Une antenne supraconductrice est formee d'un micro-pont d'une couche mince supraconductrice sur lequel un courant continu est applique. Un faisceau laser dans le visible est focalise sur le micro-pont et place le supraconducteur dans un etat hors-equilibre ou des paires sont brisees. Grace a la relaxation des quasiparticules en surplus et eventuellement de la reformation des paires supraconductrices, nous pouvons etudier la nature de la supraconductivite. L'analyse de la cinetique temporelle du champ electromagnetique emis par une telle antenne terahertz supraconductrice s'est averee utile pour decrire qualitativement les caracteristiques de celle-ci en fonction des parametres d'operation tels que le courant applique, la temperature et la puissance d'excitation. La comprehension de l'etat hors-equilibre est la cle pour comprendre le fonctionnement des antennes terahertz supraconductrices a haute temperature critique. Dans le but de comprendre ultimement cet etat hors-equilibre, nous avions besoin d'une methode et d'un modele pour extraire de facon plus systematique les proprietes intrinseques du materiau qui compose l'antenne terahertz a partir des caracteristiques d'emission de celle-ci. Nous avons developpe une procedure pour calibrer le spectrometre dans le domaine temporel en utilisant des antennes terahertz de GaAs bombarde aux protons H+ comme emetteur et detecteur. Une fois le montage calibre, nous y avons insere une antenne emettrice dipolaire de YBa 2Cu3O7-delta . Un modele avec des fonctions exponentielles de montee et de descente du signal est utilise pour lisser le spectre du champ electromagnetique de l'antenne de YBa 2Cu3O7-delta, ce qui nous permet d'extraire les proprietes intrinseques de ce dernier. Pour confirmer la validite du modele

  16. Ion Monitoring

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2003-11-18

    The apparatus and method provide a technique for significantly reducing capacitance effects in detector electrodes arising due to movement of the instrument relative to the item/location being monitored in ion detection based techniques. The capacitance variations are rendered less significant by placing an electrically conducting element between the detector electrodes and the monitored location/item. Improved sensitivity and reduced noise signals arise as a result. The technique also provides apparatus and method suitable for monitoring elongate items which are unsuited to complete enclosure in one go within a chamber. The items are monitored part by part as the pass through the instrument, so increasing the range of items or locations which can be successfully monitored.

  17. ION MAGNETRON

    DOEpatents

    Gow, J.D.; Layman, R.W.

    1962-10-31

    A magnetohydrodynamic device or plasma generator of the ion magnetron class is described wherein a long central electrode is disposed along the axis of an evacuated cylinder. A radial electric field and an axial magnetic field are provided between the cylsnder and the electrode, forming a plasma trapping and heating region. For maximum effectiveness, neutral particles from the cylinder wall must be prevented from entering such region This is effected by forming a cylindrical sheath of electrons near the cylinder wall for ionizing undesired neutral particles, which are then trapped and removed by the magnetic field. An annular filament at one end of the device provides the electrons, which follow the axial magnetic field to a reflecting electrode at the opposite end of the device. (AEC)

  18. ION SOURCE

    DOEpatents

    Brobeck, W.M.

    1959-04-14

    This patent deals with calutrons and more particularly to an arrangement therein whereby charged bottles in a calutron source unit may be replaced without admitting atmospheric air to the calutron vacuum chamber. As described, an ion unit is disposed within a vacuum tank and has a reservoir open toward a wall of the tank. A spike projects from thc source into the reservoir. When a charge bottle is placed in the reservoir, the spike breaks a frangible seal on the bottle. After the contents of the bottle are expended the bottle may be withdrawn and replaced with another charge bottle by a varuum lock arrangement in conjunction with an arm for manipulating the bottle.

  19. Ion source

    DOEpatents

    Brobeck, W. M.

    1959-04-14

    This patent deals with calutrons and more particularly to an arrangement therein whereby charged bottles in a calutron source unit may be replaced without admitting atmospheric air to the calutron vacuum chamber. As described, an ion unit is disposed within a vacuum tank and has a reservoir open toward a wall of the tank. A spike projects from the source into the reservoir. When a charge bottle is placed in the reservoir, the spike breaks a frangible seal on the bottle. After the contents of the bottle are expended the bottle may be withdrawn and replaced with another charge bottle by a vacuum lock arrangement in conjunction with an arm for manipulating the bottle.

  20. Ion mobility sensor

    DOEpatents

    Koo, Jackson C.; Yu, Conrad M.

    2005-08-23

    An ion mobility sensor which can detect both ion and molecules simultaneously. Thus, one can measure the relative arrival times between various ions and molecules. Different ions have different mobility in air, and the ion sensor enables measurement of ion mobility, from which one can identify the various ions and molecules. The ion mobility sensor which utilizes a pair of glow discharge devices may be designed for coupling with an existing gas chromatograph, where various gas molecules are already separated, but numbers of each kind of molecules are relatively small, and in such cases a conventional ion mobility sensor cannot be utilized.

  1. Ion sources for use in ion implantation

    NASA Astrophysics Data System (ADS)

    White, Nicholas R.

    1989-02-01

    This paper reviews high current ion sources suitable for commercial use. Although the production of high currents of a variety of ions is a vital consideration, this paper focuses on other aspects of ion source performance. The modern ion implanter is a major item of expensive capital equipment, with the ion source being its least reliable component. So, the most critical issues today are reliability and lifetime, as well as safety, flexibility, and ease of service. The Freeman ion source has clearly dominated the field, yet a number of alternative sources have found commercial acceptance, including microwave sources. Factors affecting the ultimate usefulness of various sources in different implantation applications are discussed.

  2. Ion funnel ion trap and process

    DOEpatents

    Belov, Mikhail E [Richland, WA; Ibrahim, Yehia M [Richland, WA; Clowers, Biran H [West Richland, WA; Prior, David C [Hermiston, OR; Smith, Richard D [Richland, WA

    2011-02-15

    An ion funnel trap is described that includes a inlet portion, a trapping portion, and a outlet portion that couples, in normal operation, with an ion funnel. The ion trap operates efficiently at a pressure of .about.1 Torr and provides for: 1) removal of low mass-to-charge (m/z) ion species, 2) ion accumulation efficiency of up to 80%, 3) charge capacity of .about.10,000,000 elementary charges, 4) ion ejection time of 40 to 200 .mu.s, and 5) optimized variable ion accumulation times. Ion accumulation with low concentration peptide mixtures has shown an increase in analyte signal-to-noise ratios (SNR) of a factor of 30, and a greater than 10-fold improvement in SNR for multiply charged analytes.

  3. Les neuropeptides gastro-intestinaux cibles des effets des rayonnements ionisants : altérations fonctionnelles

    NASA Astrophysics Data System (ADS)

    Linard, C.; Esposito, V.; Wysocki, J.; Griffiths, N. M.

    1998-04-01

    The symptoms associated with exposure to ionizing radiation are nausea, vomiting, diarrhoea. The response of the gut is complex involving modifications of motility and fluid and electrolyte transport. Gastrointestinal regulatory peptides have an important role in these functions. This study showed that radiation-induced tissue variations of neuropeptides have some repercussions on intestinal biological activity of these peptides soon after irradiation. In addition such modifications are also seen a few years after irradiation. Les symptômes associés à l'exposition aux rayonnements ionisants sont des nausées, vomissements et diarrhées. La réponse du système digestif est complexe, impliquant des modifications de la motilité et du transport d'eau et d'électrolytes. les neuropeptides gastro-intestinaux ont un rôle important dans ces fonctions. Cette étude montre que les variations tissulaires de ces neuropeptides induites par l'irradiation ont des répercussions sur l'activité biologique intestinale pour des temps précoces mais que ces perturbations sont encore visibles quelques années après l'irradiation.

  4. Comparaison des effets des irradiations γ, X et UV dans les fibres optiques

    NASA Astrophysics Data System (ADS)

    Girard, S.; Ouerdane, Y.; Baggio, J.; Boukenter, A.; Meunier, J.-P.; Leray, J.-L.

    2005-06-01

    Les fibres optiques présentent de nombreux avantages incitant à les intégrer dans des applications devant résister aux environnements radiatifs associés aux domaines civil, spatial ou militaire. Cependant, leur exposition à un rayonnement entraîne la création de défauts ponctuels dans la silice amorphe pure ou dopée qui constitue les différentes parties de la fibre optique. Ces défauts causent, en particulier, une augmentation transitoire de l'atténuation linéique des fibres optiques responsable de la dégradation voire de la perte du signal propagé dans celles-ci. Dans cet article, nous comparons les effets de deux types d'irradiation: une impulsion X et une dose γ cumulée. Les effets de ces irradiations sont ensuite comparés avec ceux induits par une insolation ultraviolette (244 nm) sur les propriétés d'absorption des fibres optiques. Nous montrons qu'il existe des similitudes entre ces différentes excitations et qu'il est possible, sous certaines conditions, d'utiliser celles-ci afin d'évaluer la capacité de certaines fibres optiques à fonctionner dans un environnement nucléaire donné.

  5. 1. ORIGINAL STONE ARCH BRIDGE OVER THE DES PLAINES RIVER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. ORIGINAL STONE ARCH BRIDGE OVER THE DES PLAINES RIVER AT NINTH STREET IN LOCKPORT. THE BRIDGE WAS BUILT ABOUT 1865. NOTE METAL CLAMP ON THE NEAR PIER AND THE 20TH CENTURY REINFORCED CONCRETE ADDITION. - Lockport Historic District, Stone Arch Bridge, Spanning Des Plaines River at Ninth Street, Lockport, Will County, IL

  6. Vers des boites quantiques a base de graphene

    NASA Astrophysics Data System (ADS)

    Branchaud, Simon

    Le graphene est un materiau a base de carbone qui est etudie largement depuis 2004. De tres nombreux articles ont ete publies tant sur les proprietes electroniques, qu'optiques ou mecaniques de ce materiel. Cet ouvrage porte sur l'etude des fluctuations de conductance dans le graphene, et sur la fabrication et la caracterisation de nanostructures gravees dans des feuilles de ce cristal 2D. Des mesures de magnetoresistance a basse temperature ont ete faites pres du point de neutralite de charge (PNC) ainsi qu'a haute densite electronique. On trouve deux origines aux fluctuations de conductance pres du PNC, soit des oscillations mesoscopiques provenant de l'interference quantique, et des fluctuations dites Hall quantique apparaissant a plus haut champ (>0.5T), semblant suivre les facteurs de remplissage associes aux monocouches de graphene. Ces dernieres fluctuations sont attribuees a la charge d'etats localises, et revelent un precurseur a l'effet Hall quantique, qui lui, ne se manifeste pas avant 2T. On arrive a extraire les parametres caracterisant l'echantillon a partir de ces donnees. A la fin de cet ouvrage, on effectue des mesures de transport dans des constrictions et ilots de graphene, ou des boites quantiques sont formees. A partir de ces mesures, on extrait les parametres importants de ces boites quantiques, comme leur taille et leur energie de charge.

  7. Peste des petits ruminants virus in Heilongjiang province, China, 2014.

    PubMed

    Wang, Jingfei; Wang, Miao; Wang, Shida; Liu, Zaisi; Shen, Nan; Si, Wei; Sun, Gang; Drewe, Julian A; Cai, Xuehui

    2015-04-01

    During March 25-May 5, 2014, we investigated 11 outbreaks of peste des petits ruminants in Heilongjiang Province, China. We found that the most likely source of the outbreaks was animals from livestock markets in Shandong. Peste des petits ruminants viruses belonging to lineages II and IV were detected in sick animals. PMID:25811935

  8. Peste des petits ruminants virus in Heilongjiang province, China, 2014.

    PubMed

    Wang, Jingfei; Wang, Miao; Wang, Shida; Liu, Zaisi; Shen, Nan; Si, Wei; Sun, Gang; Drewe, Julian A; Cai, Xuehui

    2015-04-01

    During March 25-May 5, 2014, we investigated 11 outbreaks of peste des petits ruminants in Heilongjiang Province, China. We found that the most likely source of the outbreaks was animals from livestock markets in Shandong. Peste des petits ruminants viruses belonging to lineages II and IV were detected in sick animals.

  9. ERRORS IN APPLYING LOW ION-STRENGTH ACTIVITY COEFFICIENT ALGORITHMS TO HIGHER IONIC-STRENGTH AQUATIC MEDIA

    EPA Science Inventory

    The toxicological and regulatory communities are currently exploring the use of free-ion-activity- models as a means of reducing uncertainties in current methods for assessing metals bioavailabi- lity from contaminated aquatic media. While most practitioners would support the des...

  10. Etude du processus de changement vecu par des familles ayant decide d'adopter volontairement des comportements d'attenuation des changements climatiques

    NASA Astrophysics Data System (ADS)

    Leger, Michel T.

    Les activites humaines energivores telles l'utilisation intensive de l'automobile, la surconsommation de biens et l'usage excessif d'electricite contribuent aux changements climatiques et autres problemes environnementaux. Bien que plusieurs recherches rapportent que l'etre humain est de plus en plus conscient de ses impacts sur le climat de la planete, ces memes recherches indiquent qu'en general, les gens continuent a se comporter de facon non ecologique. Que ce soit a l'ecole ou dans la communaute, plusieurs chercheurs en education relative a l'environnement estiment qu'une personne bien intentionnee est capable d'adopter des comportements plus respectueux de l'environnement. Le but de cette these etait de comprendre le processus d'integration de comportements d'attenuation des changements climatiques dans des familles. A cette fin, nous nous sommes fixe deux objectifs : 1) decrire les competences et les procedes qui favorisent l'adoption de comportements d'attenuation des changements climatiques dans des familles et 2) decrire les facteurs et les dynamiques familiales qui facilitent et limitent l'adoption de comportements d'attenuation des changements climatiques dans des familles. Des familles ont ete invitees a essayer des comportements personnels et collectifs d'attenuation des changements climatiques de sorte a integrer des modes de vie plus ecologiques. Sur une periode de huit mois, nous avons suivi leur experience de changement afin de mieux comprendre comment se produit le processus de changement dans des familles qui decident volontairement d'adopter des comportements d'attenuation des changements climatiques. Apres leur avoir fourni quelques connaissances de base sur les changements climatiques, nous avons observe le vecu de changement des familles durant huit mois d'essais a l'aide de journaux reflexifs, d'entretiens d'explicitation et du journal du chercheur. La these comporte trois articles scientifiques. Dans le premier article, nous presentons une

  11. Etude des systèmes protoplanétaires

    NASA Astrophysics Data System (ADS)

    Augereau, Jean-Charles

    2000-11-01

    Les disques de poussières et de gaz autour des étoiles rejoignant la Séquence Principale sont les sites de formation des planètes extra-solaires dont l'existence s'est vu confirmée récemment. Cette thèse aborde l'étude de la poussière des environnements circumstellaires. Elle associe des observations spatiales à haute résolution angulaire, la modélisation des propriétés physico-chimiques des poussières et leur comportement optique, la modélisation des disques optiquement fins et la dynamique des planétésimaux à l'origine des grains observés autour des étoiles âgées. Les images obtenues avec le Télescope Spatial Hubble révèlent deux nouveaux disques circumstellaires autour des étoiles HD 141569 et HD 100546, parfois classées dans la catégorie des étoiles de Herbig. Bien que les systèmes présentent des âges proches (~10 millions d'années), les morphologies très différentes des disques mettent en évidence la difficulté pour élaborer un scénario unique d'évolution des systèmes protoplanétaires. L'anneau fin de poussières autour de HR 4796A, une étoile d'âge similaire aux précédentes, est marginalement résolu depuis le sol. La modélisation complète de ce disque permet de reproduire l'ensemble des observations disponibles. Ces résultats impliquent la présence de planétésimaux, à un âge aussi peu avancé, pour repeupler le disque en poussières poreuses et essentiellement amorphes qui sont soufflées par la pression de radiation. Une modélisation dynamique du prototypique disque autour de β Pictoris est proposée. Associée à une description réaliste du comportement optique des grains, cette approche reproduit les caractéristiques générales du disque ainsi que des asymétries plus fines en supposant la présence d'une planète dans un disque de planétésimaux et en tenant compte des effets différentiels de la pression de radiation sur les grains. Enfin, le modèle de disques que j'ai développé est exploit

  12. Etude de la dynamique des porteurs dans des nanofils de silicium par spectroscopie terahertz

    NASA Astrophysics Data System (ADS)

    Beaudoin, Alexandre

    Ce memoire presente une etude des proprietes de conduction electrique et de la dynamique temporelle des porteurs de charges dans des nanofils de silicium sondes par rayonnement terahertz. Les cas de nanofils de silicium non intentionnellement dopes et dopes type n sont compares pour differentes configurations du montage experimental. Les mesures de spectroscopie terahertz en transmission montre qu'il est possible de detecter la presence de dopants dans les nanofils via leur absorption du rayonnement terahertz (˜ 1--12 meV). Les difficultes de modelisation de la transmission d'une impulsion electromagnetique dans un systeme de nanofils sont egalement discutees. La detection differentielle, une modification au systeme de spectroscopie terahertz, est testee et ses performances sont comparees au montage de caracterisation standard. Les instructions et des recommendations pour la mise en place de ce type de mesure sont incluses. Les resultats d'une experience de pompe optique-sonde terahertz sont egalement presentes. Dans cette experience, les porteurs de charge temporairement crees suite a l'absorption de la pompe optique (lambda ˜ 800 nm) dans les nanofils (les photoporteurs) s'ajoutent aux porteurs initialement presents et augmentent done l'absorption du rayonnement terahertz. Premierement, l'anisotropie de l'absorption terahertz et de la pompe optique par les nanofils est demontree. Deuxiemement, le temps de recombinaison des photoporteurs est etudie en fonction du nombre de photoporteurs injectes. Une hypothese expliquant les comportements observes pour les nanofils non-dopes et dopes-n est presentee. Troisiemement, la photoconductivite est extraite pour les nanofils non-dopes et dopes-n sur une plage de 0.5 a 2 THz. Un lissage sur la photoconductivite permet d'estimer le nombre de dopants dans les nanofils dopes-n. Mots-cles: nanofil, silicium, terahertz, conductivite, spectroscopie, photoconductivite.

  13. Anisotropie des coefficients de diffusion dans des cristaux liquides discotiques hexagonaux

    NASA Astrophysics Data System (ADS)

    Daoud, M.; Gharbia, M.; Gharbi, A.

    1994-06-01

    The diffusion constants of dyes in several hexagonal discotic liquid crystals are measured and discussed. For all the liquid crystals studied, these constants are anisotropic : the diffusion in the direction parallel to the columns is faster than that in the perpendicular plane (frac{D_allel}{D_perp}>1). The effects of the length and shape of the chains bound to the triphenylene discs are shown. The effect of the dye molecular size is also described. The study of the diffusion coefficients of hexapentoxytriphenylene (C5HET) as a function of temperature has shown that the activation energies along the columns and perpendicular to the columns are comparable. The main features of dye diffusion in the hexagonal columnar liquid crystals studied are similar to those reported in nematic phases. Les mesures des constantes de diffusion de colorants dans plusieurs cristaux liquides discotiques hexagonaux sont présentées et discutées. Pour tous les cristaux liquides étudiés, ces constantes présentent une anisotropie, avec une diffusion plus rapide parallèlement aux colonnes que perpendiculairement à celles-ci (frac{D_allel}{D_perp}>1). Des effets de longueur et de forme des chaînes branchées sur les disques de triphénylène sont mis en évidence. Il en est de même pour la taille des molécules de colorants. L'étude en fonction de la température a montré que dans le cas de l'hexapentoxytriphénylène (C5HET), les énergies d'activation dans les directions parallèle et perpendiculaire aux colonnes sont comparables. Les caractéristiques de la diffusion de colorants dans les cristaux liquides colonnaires hexagonaux étudiés sont semblables à celles des nématiques.

  14. Hans Bethe : Des etoiles a la bombe

    NASA Astrophysics Data System (ADS)

    Bonnet-Bidaud, J. M.

    1996-06-01

    Il comprit le premier comment brillent les etoiles. Il fut aussi de cette poignee de scientifiques qui, dans le secret de Los Alamos, mirent au point la tristement celebre bombe atomique. Hans Bethe est l'un des derniers geants qui auront marque la physique de ce siecle d'une empreinte indelebile. C'est dans le bureau 01 du prestigieux laboratoire Kellog de l'institut Caltech qu'il a bien voulu retracer pour nous son impressionnante carriere, et revenir sur les motivations qui ont guide ses pas.

  15. Ion heating via turbulent ion acoustic waves.

    NASA Technical Reports Server (NTRS)

    Taylor, R. J.; Coroniti, F. V.

    1972-01-01

    The ion acoustic turbulence in the turbulent-heating experiment reported is excited by the ion-ion beam instability. Graphs are presented, showing the spatial evolution of the parallel ion beam energy and the spatial evolution of the ion acoustic turbulent wave spectrum. The observed characteristics of test waves in a turbulent beam-plasma imply that wave saturation is a dynamic balance between the emission of waves by the beam and the destruction or damping of wave coherence by the turbulent diffusion of particle orbits.

  16. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  17. Solar Wind Sputtering of Lunar Soil Analogs: The Effect of Ionic Charge and Mass

    NASA Technical Reports Server (NTRS)

    Hijazi, H.; Bannister, M. E.; Meyer, F. W.; Rouleau, C. M.; Barghouty, A. F.; Rickman, D. L.; Hijazi, H.

    2014-01-01

    In this contribution we report sput-tering measurements of anorthite, an analog material representative of the lunar highlands, by singly and multicharged ions representative of the solar wind. The ions investigated include protons, as well as singly and multicharged Ar ions (as proxies for the heavier solar wind constituents), in the charge state range +1 to +9, and had a fixed solar-wind-relevant impact velocity of approximately 310 km/s or 500 eV/ amu. The goal of the measurements was to determine the sputtering contribution of the heavy, multicharged minority solar wind constituents in comparison to that due to the dominant H+ fraction.

  18. Microfabricated ion frequency standard

    DOEpatents

    Schwindt, Peter; Biedermann, Grant; Blain, Matthew G.; Stick, Daniel L.; Serkland, Darwin K.; Olsson, III, Roy H.

    2010-12-28

    A microfabricated ion frequency standard (i.e. an ion clock) is disclosed with a permanently-sealed vacuum package containing a source of ytterbium (Yb) ions and an octupole ion trap. The source of Yb ions is a micro-hotplate which generates Yb atoms which are then ionized by a ultraviolet light-emitting diode or a field-emission electron source. The octupole ion trap, which confines the Yb ions, is formed from suspended electrodes on a number of stacked-up substrates. A microwave source excites a ground-state transition frequency of the Yb ions, with a frequency-doubled vertical-external-cavity laser (VECSEL) then exciting the Yb ions up to an excited state to produce fluorescent light which is used to tune the microwave source to the ground-state transition frequency, with the microwave source providing a precise frequency output for the ion clock.

  19. Ion sources for ion implantation technology (invited)

    SciTech Connect

    Sakai, Shigeki Hamamoto, Nariaki; Inouchi, Yutaka; Umisedo, Sei; Miyamoto, Naoki

    2014-02-15

    Ion sources for ion implantation are introduced. The technique is applied not only to large scale integration (LSI) devices but also to flat panel display. For LSI fabrication, ion source scheduled maintenance cycle is most important. For CMOS image sensor devices, metal contamination at implanted wafer is most important. On the other hand, to fabricate miniaturized devices, cluster ion implantation has been proposed to make shallow PN junction. While for power devices such as silicon carbide, aluminum ion is required. For doping processes of LCD fabrication, a large ion source is required. The extraction area is about 150 cm × 10 cm, and the beam uniformity is important as well as the total target beam current.

  20. Intense ion beams accelerated by ultra-intense laser pulses

    NASA Astrophysics Data System (ADS)

    Roth, Markus; Cowan, T. E.; Gauthier, J. C.; Vehn, J. Meyer-Ter; Allen, M.; Audebert, P.; Blazevic, A.; Fuchs, J.; Geissel, M.; Hegelich, M.; Karsch, S.; Pukhov, A.; Schlegel, T.

    2002-04-01

    The discovery of intense ion beams off solid targets irradiated by ultra-intense laser pulses has become the subject of extensive international interest. These highly collimated, energetic beams of protons and heavy ions are strongly depending on the laser parameters as well as on the properties of the irradiated targets. Therefore we have studied the influence of the target conditions on laser-accelerated ion beams generated by multi-terawatt lasers. The experiments were performed using the 100 TW laser facility at Laboratoire pour l'Utilisation des Laser Intense (LULI). The targets were irradiated by pulses up to 5×1019 W/cm2 (~300 fs,λ=1.05 μm) at normal incidence. A strong dependence on the surface conditions, conductivity, shape and purity was observed. The plasma density on the front and rear surface was determined by laser interferometry. We characterized the ion beam by means of magnetic spectrometers, radiochromic film, nuclear activation and Thompson parabolas. The strong dependence of the ion beam acceleration on the conditions on the target back surface was confirmed in agreement with predictions based on the target normal sheath acceleration (TNSA) mechanism. Finally shaping of the ion beam has been demonstrated by the appropriate tailoring of the target. .

  1. Sécurité au-delà des mythes et des croyances

    ScienceCinema

    None

    2016-07-12

    Présentation orale en français, support visuel en français et en anglais. La pire des failles de sécurité est l'impression de sécurité. Le décalage entre la compréhension que l’on a des technologies utilisées, et leurs potentiels réels, ainsi que l'impact potentiellement négatif qu'elles peuvent avoir sur nos vies, n'est pas toujours compris, ou pris en compte par la plupart d'entre-nous. On se contente de nos perceptions pour ne pas avoir à se confronter à la réalité... Alors qu'en est-il vraiment ? En matière de sécurité qui de l'humain ou des technologies a le contrôle ?

  2. Evaluation des connaissances des parents sur les bronchiolites aiguës

    PubMed Central

    Gueddari, Widad; Tazi, Abderrahmane; Ouardi, Amine; Nani, Samira; Zineddine, Abdelhadi

    2014-01-01

    Les infections respiratoires (IR) constituent la deuxième cause de mortalité infantile au Maroc, dû en partie à l'absence d'information et de sensibilisation. Le but de ce travail était d’évaluer les connaissances des parents sur la bronchiolite aiguë, infection respiratoire très fréquente. Nous avons réalisé une enquête basée sur un questionnaire, auprès de parents de nourrissons consultants pour toux, avec ou sans gêne respiratoire. 180 parents ont été inclus dans l’étude. Les parents pensaient que l'infection respiratoire était secondaire au climat froid (96%); seuls 4% ont évoqué une origine infectieuse. Aucun des parents ne savait que le lavage des mains était un moyen de prévention de la transmission. Les parents ont majoritairement répondu que la kinésithérapie respiratoire ne servait à rien (65%), et qu'elle était nocive (24.5%). Ce manque de connaissances fondamentales en matière d'IR et de bronchiolite en particulier, devrait inciter à entreprendre un programme de sensibilisation PMID:25328606

  3. Ion specific effects: decoupling ion-ion and ion-water interactions

    PubMed Central

    Song, Jinsuk; Kang, Tae Hui; Kim, Mahn Won; Han, Songi

    2015-01-01

    Ion-specific effects in aqueous solution, known as the Hofmeister effect is prevalent in diverse systems ranging from pure ionic to complex protein solutions. The objective of this paper is to explicitly demonstrate how complex ion-ion and ion-water interactions manifest themselves in the Hofmeister effects, based on a series of recent experimental observation. These effects are not considered in the classical description of ion effects, such as the Deryaguin-Landau-Verwey-Overbeek (DLVO) theory that, likely for that reason, fail to describe the origin of the phenomenological Hofmeister effect. However, given that models considering the basic forces of electrostatic and van der Waals interactions can offer rationalization for the core experimental observations, a universal interaction model stands a chance to be developed. In this perspective, we separately derive the contribution from ion-ion electrostatic interaction and ion-water interaction from second harmonic generation (SHG) data at the air-ion solution interface, which yields an estimate of ion-water interactions in solution. Hofmeister ion effects observed on biological solutes in solution should be similarly influenced by contributions from ion-ion and ion-water interactions, where the same ion-water interaction parameters derived from SHG data at the air-ion solution interface could be applicable. A key experimental data set available from solution systems to probe ion-water interaction is the modulation of water diffusion dynamics near ions in bulk ion solution, as well as near biological liposome surfaces. It is obtained from Overhauser dynamic nuclear polarization (ODNP), a nuclear magnetic resonance (NMR) relaxometry technique. The surface water diffusivity is influenced by the contribution from ion-water interactions, both from localized surface charges and adsorbed ions, although the relative contribution of the former is larger on liposome surfaces. In this perspective, ion-water interaction

  4. PULSED ION SOURCE

    DOEpatents

    Anderson, C.E.; Ehlers, K.W.

    1958-06-17

    An ion source is described for producing very short high density pulses of ions without bcam scattering. The ions are created by an oscillating electron discharge within a magnetic field. After the ions are drawn from the ionization chamber by an accelerating electrode the ion beam is under the influence of the magnetic field for separation of the ions according to mass and, at the same time, passes between two neutralizing plntes maintained nt equal negative potentials. As the plates are formed of a material having a high ratio of secondary electrons to impinging ions, the ion bombardment of the plntes emits electrons which neutralize the frirge space-charge of the beam and tend to prevent widening of the beam cross section due to the mutual repulsion of the ions.

  5. Structured back gates for high-mobility two-dimensional electron systems using oxygen ion implantation

    NASA Astrophysics Data System (ADS)

    Berl, M.; Tiemann, L.; Dietsche, W.; Karl, H.; Wegscheider, W.

    2016-03-01

    We present a reliable method to obtain patterned back gates compatible with high mobility molecular beam epitaxy via local oxygen ion implantation that suppresses the conductivity of an 80 nm thick silicon doped GaAs epilayer. Our technique was optimized to circumvent several constraints of other gating and implantation methods. The ion-implanted surface remains atomically flat which allows unperturbed epitaxial overgrowth. We demonstrate the practical application of this gating technique by using magneto-transport spectroscopy on a two-dimensional electron system (2DES) with a mobility exceeding 20 × 106 cm2/V s. The back gate was spatially separated from the Ohmic contacts of the 2DES, thus minimizing the probability for electrical shorts or leakage and permitting simple contacting schemes.

  6. DES the year in review: controversies.

    PubMed

    Garg, S; Bourantas, C; Serruys, P W

    2013-04-01

    Drug-eluting stents (DES) have transformed interventional cardiology over the past decade. Whilst their efficacy has rarely been called into question, there have been concerns over the safety of the early devices, which has prompted the development of new coronary stents. Many of these new devices have entered clinical practice, however questions remain as to whether they offer the improvements in clinical outcomes that were originally anticipated. In addition, there is a debate whether the reported high efficacy of these devices enables percutaneous coronary intervention (PCI) to be performed in patient and lesion sub-groups previous entirely the domain of the cardiac surgeon. This review paper addresses these outstanding questions. PMID:23492595

  7. Formation et Evolution des Quasars et Contraintes cosmologiques

    NASA Astrophysics Data System (ADS)

    Hatziminaoglou, Evanthia

    2000-06-01

    Cette thèse porte sur l'étude de l'évolution des quasars. Elle en aborde certains aspects théoriques et observationnels, ainsi que la construction des grands échantillons de quasars dans le but à long terme de combiner le tout dans un test cosmologique géométrique pour déterminer les valeurs des paramètres cosmologiques Omega et Lambda. Les paramètres cosmologiques Omegaspan>et Lambdaspan>décrivent la géométrie globale de l'Univers. En faisant des hypothèses raisonnables sur la distribution spatiale et l'évolution des objets astrophysiques (galaxies, amas des galaxies, quasars), on peut déterminer les valeurs de ces paramètres qui sont cohérentes avec ces hypothèses. Les tests cosmologiques traditionnels ont besoin de ''chandelles standards'', objets dont les propriétés intrinsèques sont indépendantes des distances. De tels objets sont probablement fictifs. Néanmoins, certains de ces tests cosmologiques peuvent être adaptés si l'évolution individuelle, ou au moins l'évolution statistique d'une population d'objets est connue. La question de la nature de l'évolution des quasars a très vite été posée et des réponses ''phénoménologiques'' ont d'abord été données. Ces réponses ne faisaient que donner une forme mathématique à l'évolution mais n'expliquaient rien de la physique duphénomène. Les premières tentatives de construction d'un modèle physique, liées au processus d'accrétion sur un trou noir et à la théorie de la formation de l'Univers ont commencé à la fin des années 80. Depuis, des dizaines de modèles tentent d'expliquer les observations, qui sont les résultats de l'étude d'objets de plus en plus nombreux. Au cours de cette thèse, le test V/Vmax a été appliqué sur l'échantillon du Large Bright Quasar Survey en montrant 1) que l'échantillon était biaisé à cause des critères de sélection et 2) que la (simple) loi de Pure Evolution en Luminosité n'était pas une bonne approximation à tout

  8. Broad beam ion implanter

    DOEpatents

    Leung, K.N.

    1996-10-08

    An ion implantation device for creating a large diameter, homogeneous, ion beam is described, as well as a method for creating same, wherein the device is characterized by extraction of a diverging ion beam and its conversion by ion beam optics to an essentially parallel ion beam. The device comprises a plasma or ion source, an anode and exit aperture, an extraction electrode, a divergence-limiting electrode and an acceleration electrode, as well as the means for connecting a voltage supply to the electrodes. 6 figs.

  9. Broad beam ion implanter

    DOEpatents

    Leung, Ka-Ngo

    1996-01-01

    An ion implantation device for creating a large diameter, homogeneous, ion beam is described, as well as a method for creating same, wherein the device is characterized by extraction of a diverging ion beam and its conversion by ion beam optics to an essentially parallel ion beam. The device comprises a plasma or ion source, an anode and exit aperture, an extraction electrode, a divergence-limiting electrode and an acceleration electrode, as well as the means for connecting a voltage supply to the electrodes.

  10. Le syndrome des enfants battus: aspects cliniques et radiologiques

    PubMed Central

    Jlalia, Zied; Znaigui, Talel; Smida, Mahmoud

    2016-01-01

    La maltraitance physique des enfants ou le syndrome des enfants battus est responsable de plus de 75.000 décès par an en France. Ce problème de santé publique reste sous diagnostiqué en Tunisie et dans le monde. Le chemin a été laborieux pour la reconnaissance du syndrome des enfants battus dans certaines sociétés même occidentales. Nous avons voulus exposer ce problème aux praticiens afin qu'il soit mieux diagnostiqué et pris en charge. La maltraitance physique des enfants est appelée à tort syndrome de Silverman qui ne regroupe en fait que les lésions squelettiques chez ces enfants tels que les fractures. Mots clés: Fracture, maltraitance, enfant, neuro-radiologie PMID:27642408

  11. Discovery and Classification of DES15S2kqw

    NASA Astrophysics Data System (ADS)

    Kasai, E.; Bassett, B.; Crawford, S.; Kniazev, A.; Childress, M.; D'Andrea, C.; Smith, M.; Sullivan, M.; Maartens, R.; Gupta, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Casas, R.; Castander, F. J.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; Gladney, L.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Nichol, R.; Papadopoulos, A.

    2015-10-01

    We report optical spectroscopy of DES15S2kqw discovered by the Dark Energy Survey. The spectrum (380-820nm) was obtained using the Robert Stobie Spectrograph (RSS) on the South African Large Telescope (SALT).

  12. 2. Photocopied 1972 from Ecole imperiale des ponts et chaussees, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Photocopied 1972 from Ecole imperiale des ponts et chaussees, Collection de Dessins Distribues aus eleves, (n.d. and no place), ORIGINAL FINK TRUSS BRIDGE, 1852. - Baltimore & Ohio Railroad, Fairmont Bridge, Spanning Monongahela River, Fairmont, Marion County, WV

  13. Die Evolution des Universums. Eine Geschichte der Kosmologie.

    NASA Astrophysics Data System (ADS)

    Hiller, H.

    This volume covers in an elementary course a historical overview on cosmology ranging from the ancient aspects up to big bang theory and the concepts of inflationary universe and grand unified theories. Contents: 1. Auf dem Wege zur Wissenschaft. 2. Die neue Kosmologie. 3. Die Struktur des Weltalls. 4. Dramatik im Weltall. 5. Die endliche Welt. 6. Die Evolution des frühen Universums. 7. Die Zukunft. 8. Die neue Teleologie. 9. Das Leben.

  14. ION COMPOSITION ELUCIDATION (ICE)

    EPA Science Inventory



    Ion Composition Elucidation (ICE) utilizes selected ion recording with a double focusing mass spectrometer to simultaneously determine exact masses and relative isotopic abundances from mass peak profiles. These can be determined more accurately and at higher sensitivity ...

  15. Applications of decelerated ions

    SciTech Connect

    Johnson, B.M.

    1985-03-01

    Many facilities whose sole purpose had been to accelerate ion beams are now becoming decelerators as well. The development and current status of accel-decel operations is reviewed here. Applications of decelerated ions in atomic physics experiments are discussed.

  16. Identification et prise en charge des femmes ayant des antécédents familiaux de cancer du sein

    PubMed Central

    Heisey, Ruth; Carroll, June C.

    2016-01-01

    Résumé Objectif Résumer les meilleures données portant sur les stratégies d’identification et de prise en charge des femmes qui présentent des antécédents familiaux de cancer du sein. Sources d’information Une recherche a été effectuée sur PubMed à l’aide des mots-clés anglais suivants : breast cancer, guidelines, risk, family history, management et magnetic resonance imaging screening, entre 2000 et 2016. La plupart des données sont de niveau II. Message principal Une bonne anamnèse familiale est essentielle lors de l’évaluation du risque de cancer du sein afin d’identifier les femmes qui sont candidates à une recommandation en counseling génétique pour un éventuel test génétique. On peut sauver des vies en offrant aux femmes porteuses d’une mutation au gène BRCA des interventions chirurgicales de réduction des risques (mastectomie bilatérale prophylactique, salpingo-ovariectomie bilatérale). Il faut encourager toutes les femmes qui présentent des antécédents familiaux de cancer du sein à demeurer actives et à limiter leur consommation d’alcool à moins de 1 verre par jour; certaines femmes sont admissibles à la chimioprévention. Il faut offrir aux femmes dont le risque à vie de cancer du sein est de 20 à 25 % ou plus un dépistage poussé par imagerie par résonance magnétique en plus d’une mammographie. Conclusion Une vie saine et la chimioprévention (chez les candidates) pourraient réduire l’incidence du cancer du sein; le dépistage poussé pourrait entraîner une détection plus précoce. Le fait d’aiguiller des femmes porteuses d’une mutation au BRCA vers la chirurgie de réduction des risques sauve des vies. PMID:27737991

  17. Profil épidémiologique des tumeurs malignes primitives des glandes salivaires : à propos de 154 cas

    PubMed Central

    Setti, Khadija; Mouanis, Mohamed; Moumni, Abdelmounim; Maher, Mostafa; Harmouch, Amal

    2014-01-01

    Introduction Les tumeurs des glandes salivaires sont des tumeurs rares représentant 3à 5% des tumeurs de la tête et du cou. La classification de l'OMS 2005 distingue les tumeurs épithéliales, les tumeurs mésenchymateuses, les tumeurs hématologiques et les tumeurs secondaires. Méthodes Notre travail consiste en une étude rétrospective réalisée sur une période de 10 ans allant de janvier 2002 à janvier 2012. Les critères d'inclusion étaient: l'âge, le sexe, le siège de la tumeur et le type histologique. Résultats L'incidence annuelle des tumeurs malignes primitives des glandes salivaires dans notre série était de 15 cas par an. Cent cinquante quatre cas de tumeurs malignes primitives des glandes salivaires ont été colligés sans prédominance de sexe (78 femmes (50,6%) et 76 hommes (49,4%)). La moyenne d'âge était de 60 ans avec des extrêmes de 4 et 83 ans et un pic de fréquence entre 51et 70 ans. Deux tiers des cas (65%) avaient une localisation au niveau des glandes principales avec 66 cas au niveau de la parotide (43%) et 34 cas au niveau de la glande sous maxillaire (22%). Cinquante quatre patients avaient une tumeur maligne des glandes salivaires accessoires (35%) dont 61% au niveau du palais. Aucun cas de tumeur maligne de la glande sublinguale n'a été recensé dans notre étude. Le type histologique prédominant dans notre série était le carcinome adénoïde kystique et retrouvé chez 43 patients (27,9%), suivi de l'adénocarcinome sans autre indication chez 37 patients (24%) puis du carcinome mucoépidermoïde chez 16 patients (10,4%) et de l'adénocarcinome polymorphe de bas grade également chez 16 patients (10. 4%). Conclusion Les tumeurs malignes des glandes salivaires représentent un ensemble hétérogène de maladies de caractérisation complexe et de fréquence variable. PMID:25120861

  18. Physical characteristics of stream subbasins in the Des Moines River, Upper Des Moines River, and East Fork Des Moines River basins, southern Minnesota and northern Iowa

    USGS Publications Warehouse

    Sanocki, Christopher A.

    2000-01-01

    Data that describe the physical characteristics of stream subbasins upstream from selected sites on streams in the Des Moines River, Upper Des Moines River, and East Fork Des Moines River Basins, located in southwestern Minnesota, and northwestern Iowa, are presented in this report. The physical characteristics are the drainage area of the subbasin, the percentage area of the subbasin covered only by lakes, the percentage area of the subbasin covered by both lakes and wetlands, the main-channel length, and the main-channel slope. Stream sites include outlets of subbasins of at least 5 square miles, and locations of U.S. Geological Survey high-flow, and continuous-record gaging stations.

  19. [Le leadership en santé et l'éthique de la gestion des attentes des soignants et des patients].

    PubMed

    Browne, Alister

    2016-03-01

    Les dispensateurs de soins et les patients sont souvent déçus du niveau de soins que les hôpitaux publics peuvent prodiguer. La solution consiste à réduire les attentes. Les dispensateurs devraient être amenés à considérer que leur obligation consiste à prodiguer les meilleurs soins en fonction des ressources. Le public devrait être bien informé des services que les hôpitaux de soins actifs peuvent ou non lui offrir et participer aux prises de décision. Les leaders en santé peuvent jouer des rôles novateurs à cet égard.

  20. Negative ion generator

    DOEpatents

    Stinnett, Regan W.

    1984-01-01

    A negative ion generator is formed from a magnetically insulated transmission line having a coating of graphite on the cathode for producing negative ions and a plurality of apertures on the opposed anode for the release of negative ions. Magnetic insulation keeps electrons from flowing from the cathode to the anode. A transverse magnetic field removes electrons which do escape through the apertures from the trajectory of the negative ions.

  1. SEPARATION OF PLUTONYL IONS

    DOEpatents

    Connick, R.E.; McVey, Wm.H.

    1958-07-15

    A process is described for separating plutonyl ions from the acetate ions with which they are associated in certaln carrier precipitation methods of concentrating plutonium. The method consists in adding alkaline earth metal ions and subsequently alkalizing the solution, causing formation of an alkaltne earth plutonate precipitate. Barium hydroxide is used in a preferred embodiment since it provides alkaline earth metal ion and alkalizes the solution in one step forming insoluble barium platonate.

  2. Intense ion beam generator

    DOEpatents

    Humphries, Jr., Stanley; Sudan, Ravindra N.

    1977-08-30

    Methods and apparatus for producing intense megavolt ion beams are disclosed. In one embodiment, a reflex triode-type pulsed ion accelerator is described which produces ion pulses of more than 5 kiloamperes current with a peak energy of 3 MeV. In other embodiments, the device is constructed so as to focus the beam of ions for high concentration and ease of extraction, and magnetic insulation is provided to increase the efficiency of operation.

  3. Negative ion generator

    DOEpatents

    Stinnett, R.W.

    1984-05-08

    A negative ion generator is formed from a magnetically insulated transmission line having a coating of graphite on the cathode for producing negative ions and a plurality of apertures on the opposed anode for the release of negative ions. Magnetic insulation keeps electrons from flowing from the cathode to the anode. A transverse magnetic field removes electrons which do escape through the apertures from the trajectory of the negative ions. 8 figs.

  4. Mecanique et mecanisme de la dechirure des materiaux textiles

    NASA Astrophysics Data System (ADS)

    Triki, Ennouri

    Cette thèse vise à apporter une contribution à l’étude et à la modélisation de la déchirure des textiles et des textiles enduits. Notons que la résistance à la déchirure est l’une des caractéristiques mesurées pour les équipements de protection contre les agresseurs mécaniques en milieu de travail. Jusqu'à présent, ce comportement en déchirure a été étudié en mesurant la force de déchirure et le travail de déchirure. De fait, aucun critère de rupture en déchirure n’existe actuellement. Par conséquent, en s’inspirant de la théorie du Griffith et de la mécanique de la rupture, une formulation d’un nouveau critère de rupture des structures textiles a été proposée. Cette approche offre la possibilité de déterminer d’une manière plus précise l’énergie nécessaire pour la création d’une nouvelle surface de rupture. Ce critère nous permet d’analyser l’effet des caractéristiques des tissus sur la variation de l’énergie de rupture. Cette étude montre que la résistance au glissement des fils dans la structure est le principal facteur qui contrôle la propagation de la fissure. En se basant sur la théorie de la mécanique de la rupture, un modèle de calcul de l’énergie de rupture par déchirure a été aussi élaboré. Ce modèle de déchirure relie l’énergie aux paramètres caractérisant les phénomènes affectant la déchirure des tissus, notamment la force de glissement et la force à la rupture des fils. Cette modélisation a tenu compte de certaines caractéristiques des tissus tels que l’épaisseur du matériau, la densité des fils, etc. Par l’étude de la variation de l’énergie de rupture par déchirure en fonction du rapport établi entre la force à la rupture et la force de glissement d’un fil ( FYB/FS), l’effet des mécanismes de la propagation de la fissure dans les tissus sur leur comportement en déchirure a été aussi observé. Les résultats obtenus

  5. CALUTRON ION SOURCE

    DOEpatents

    Oppenheimer, F.F.

    1959-06-01

    A shielding arrangement for eliminating oscillating electrons in the ion source region of calutrons is offered. Metal plates are attached to the ion generator so as to intercept the magnetic field between ion generator and accelerating electrode. The oscillating electrons are discharged on the plates. (T.R.H.)

  6. Negative Ion Density Fronts

    SciTech Connect

    Igor Kaganovich

    2000-12-18

    Negative ions tend to stratify in electronegative plasmas with hot electrons (electron temperature Te much larger than ion temperature Ti, Te > Ti ). The boundary separating a plasma containing negative ions, and a plasma, without negative ions, is usually thin, so that the negative ion density falls rapidly to zero-forming a negative ion density front. We review theoretical, experimental and numerical results giving the spatio-temporal evolution of negative ion density fronts during plasma ignition, the steady state, and extinction (afterglow). During plasma ignition, negative ion fronts are the result of the break of smooth plasma density profiles during nonlinear convection. In a steady-state plasma, the fronts are boundary layers with steepening of ion density profiles due to nonlinear convection also. But during plasma extinction, the ion fronts are of a completely different nature. Negative ions diffuse freely in the plasma core (no convection), whereas the negative ion front propagates towards the chamber walls with a nearly constant velocity. The concept of fronts turns out to be very effective in analysis of plasma density profile evolution in strongly non-isothermal plasmas.

  7. Ion-kill dosimetry

    NASA Technical Reports Server (NTRS)

    Katz, R.; Cucinotta, F. A.; Fromm, M.; Chambaudet, A.

    2001-01-01

    Unanticipated late effects in neutron and heavy ion therapy, not attributable to overdose, imply a qualitative difference between low and high LET therapy. We identify that difference as 'ion kill', associated with the spectrum of z/beta in the radiation field, whose measurement we label 'ion-kill dosimetry'.

  8. Les sarcomes des tissus mous: à propos de 33 cas

    PubMed Central

    Abdou, Jiddou; Elkabous, Mustapha; M'rabti, Hind; Errihani, Hassan

    2015-01-01

    L'objectif de cette étude est de rapporter les particularités épidémiologiques, cliniques, histologiques, thérapeutiques et évolutives des sarcomes des tissus mous à l'Institut National d'Oncologie et de définir les facteurs influençant la survie des patients. C'est une étude rétrospective de 33 cas de sarcome des tissus mous, colligés entre janvier 2008 et décembre 2010. Les critères d’éligibilité étaient un âge supérieur à 16 ans, une épreuve histologique d'un sarcome des tissus mous à l'exclusion des tumeurs stromales gastro-intestinales (GIST). Les items recueillis étaient: épidémiologiques, cliniques, histologiques, Radiologiques, et thérapeutiques. Des analyses univariées puis multivariées ont été réalisées à la recherche de facteurs influençant la survie à 2 ans. Il s'agit de 33 cas, 17 Hommes et 16 Femmes, l’âge moyen était de 43,21 ans (Extrêmes= 18-76 ans). La tumeur était localisée aux extrémités dans 24 cas (72,72%). Le type histologique prédominant était le Liposarcome dans 9 cas (27,27%). Le stade tumoral était localisé dans 25 cas (75,8%), métastatique dans 8 cas (24,2%). Vingt-cinq tumeurs ont été traitées chirurgicalement dont 21 cas (84%) de chirurgie conservatrice et 4 cas (16%) de chirurgie radicale. La radiothérapie a été réalisée chez 10 patients (30,3%). La chimiothérapie a été faite chez 20 patients. En analyse univariée les facteurs pronostiques étaient l’âge (p=0,03) et le stade tumoral (p=0,09). L’âge et le stade tumoral sont des facteurs pronostiques influençant la survie des sarcomes des tissus mous. PMID:27022434

  9. [Development of metal ions analysis by ion chromatography].

    PubMed

    Yu, Hong; Wang, Yuxin

    2007-05-01

    Analysis of metal ions by ion chromatography, including cation-exchange ion chromatography, anion-exchange ion chromatography and chelation ion chromatography, is reviewed. The cation-exchange ion chromatography is a main method for the determination of metal ions. Stationary phases in cation-exchange ion chromatography are strong acid cation exchanger (sulfonic) and weak acid cation exchanger (carboxylic). Alkali metal ions, alkaline earth metal ions, transition metal ions, rare earth metal ions, ammonium ions and amines can be analyzed by cation-exchange ion chromatography with a suitable detector. The anion-exchange ion chromatography is suitable for the separation and analysis of alkaline earth metal ions, transition metal ions and rare earth metal ions. The selectivity for analysis of metal ions with anion-exchange ion chromatography is good. Simultaneous determination of metal ions and inorganic anions can be achieved using anion-exchange ion chromatography. Chelation ion chromatography is suitable for the determination of trace metal ions in complex matrices. A total of 125 references are cited.

  10. La planification préalable des soins pour les patients en pédiatrie

    PubMed Central

    2008-01-01

    RÉSUMÉ Les progrès médicaux et technologiques ont permis d’ac-croître les taux de survie et d’améliorer la qualité de vie des nourrissons, des enfants et des adolescents ayant des maladies chroniques mettant la vie en danger. La planifi-cation préalable des soins inclut le processus relié aux discussions sur les traitements essentiels au maintien de la survie et la détermination des objectifs des soins de longue durée. Les dispensateurs de soins pédiatriques ont l’obligation éthique d’assimiler cet aspect des soins médicaux. Le présent document de principes vise à aider les dispensateurs de soins à discuter de la planification préalable des soins des patients pédiatriques dans diverses situations. La planification préalable des soins exige des communications efficaces afin de clarifier les objectifs des soins et de s’entendre sur les traitements pertinents ou non pour réaliser ces objectifs, y compris les mesures de réanimation et les mesures palliatives.

  11. ION PRODUCING MECHANISM

    DOEpatents

    Backus, J.G.

    1958-08-19

    A novel ion source is described for use in a calutron which has the prime adwantage of reducing the nunnber of unwanted ions in the ion generating mechamism.An important feature of the invention resides In an arc chamber having a lining of the polyisotopic material to be treated In the calutron and bombardment of the linirg with positive ions of a light gas to induce sputtering and ionization of the lining. With the reduction of unwanted ions in the source beam provided by the described source, the calutron operation may be more accurately controlled.

  12. PULSED ION SOURCE

    DOEpatents

    Ford, F.C.; Ruff, J.W.; Zizzo, S.G.; Cook, B.

    1958-11-11

    An ion source is described adapted for pulsed operation and producing copious quantities of ions with a particular ion egress geometry. The particular source construction comprises a conical member having a conducting surface formed of a metal with a gas occladed therein and narrow non-conducting portions hereon dividing the conducting surface. A high voltage pulse is applied across the conducting surface or producing a discharge across the surface. After the gas ions have been produced by the discharge, the ions are drawn from the source in a diverging conical beam by a specially constructed accelerating electrode.

  13. De l'importance des orbites periodiques: Detection et applications

    NASA Astrophysics Data System (ADS)

    Doyon, Bernard

    L'ensemble des Orbites Periodiques Instables (OPIs) d'un systeme chaotique est intimement relie a ses proprietes dynamiques. A partir de l'ensemble (en principe infini) d'OPIs cachees dans l'espace des phases, on peut obtenir des quantites dynamiques importantes telles les exposants de Lyapunov, la mesure invariante, l'entropie topologique et la dimension fractale. En chaos quantique (i.e. l'etude de systemes quantiques qui ont un equivalent chaotique dans la limite classique), ces memes OPIs permettent de faire le pont entre le comportement classique et quantique de systemes non-integrables. La localisation de ces cycles fondamentaux est un probleme complexe. Cette these aborde dans un premier temps le probleme de la detection des OPIs dans les systemes chaotiques. Une etude comparative de deux algorithmes recents est presentee. Nous approfondissons ces deux methodes afin de les utiliser sur differents systemes dont des flots continus dissipatifs et conservatifs. Une analyse du taux de convergence des algorithmes est aussi realisee afin de degager les forces et les limites de ces schemes numeriques. Les methodes de detection que nous utilisons reposent sur une transformation particuliere de la dynamique initiale. Cette astuce nous a inspire une methode alternative pour cibler et stabiliser une orbite periodique quelconque dans un systeme chaotique. Le ciblage est en general combine aux methodes de controle pour stabiliser rapidement un cycle donne. En general, il faut connaitre la position et la stabilite du cycle en question. La nouvelle methode de ciblage que nous presentons ne demande pas de connaitre a priori la position et la stabilite des orbites periodiques. Elle pourrait etre un outil complementaire aux methodes de ciblage et de controle actuelles.

  14. Catalog Production for the DES Blind Cosmology Challenge

    NASA Astrophysics Data System (ADS)

    Busha, Michael T.; Wechsler, R. H.; Becker, M. R.; Erickson, B.; Evrard, A. E.

    2013-01-01

    The Blind Cosmology Challenge (BCC) is an effort by the Dark Energy Survey (DES) to test analysis tools for extracting cosmological information using a set of detailed synthetic galaxy catalogs. Here, we describe the creation of these synthetic sky catalogs based on requirements of the optical (DES) and the near-IR VISTA Hemisphere Survey, producing catalogs covering a quarter of the sky to z ˜ 2, with sources complete to r ˜ 25. Starting with a nested set of lightcone outputs of large, N-body simulation, galaxies are assigned to the dark matter distribution using an empirical algorithm that is tunable to match observed evolution of low-order galaxy population properties (counts and spatial clustering) in luminosity-color-density space. Galaxies are lensed by matter along the line of sight (including magnification, shape distortion, and multiple images), using a new algorithm that calculates shear with 3.22 arcsec resolution at galaxy positions in the full catalog. The catalog is well suited to support DES+VISTA joint studies of galaxy clustering, groups and clusters of galaxies, and gravitational lensing, and we highlight their application to the ongoing DES BBCC. Catalogs include ˜320 million galaxies and ˜150 million stars, with realistic colors, shapes and photometric errors. Using the expected DES photometric errors, three independent photometric redshift codes are run on the catalog, two of which produce full probability distributions. The synthetic observable catalog includes object position, magnitudes in the DES and VISTA bands, photometric errors, photometric redshifts, size, ellipticity, for each of ˜ 500 million objects. The galaxy distribution is additionally masked appropriately for the 5000 square degree DES footprint, including the impact of bright stars. In addition, we offer separate catalogs with magnitudes for additional existing and planned surveys, including SDSS, CFHTLS, HSC, LSST, and Euclid.

  15. Ion cyclotron resonance cell

    DOEpatents

    Weller, R.R.

    1995-02-14

    An ion cyclotron resonance cell is disclosed having two adjacent sections separated by a center trapping plate. The first section is defined by the center trapping plate, a first end trapping plate, and excitation and detector electrodes. The second section includes a second end trapping plate spaced apart from the center plate, a mirror, and an analyzer. The analyzer includes a wavelength-selective light detector, such as a detector incorporating an acousto-optical device (AOD) and a photodetector. One or more ion guides, grounded plates with holes for the ion beam, are positioned within the vacuum chamber of the mass spectrometer between the ion source and the cell. After ions are trapped and analyzed by ion cyclotron resonance techniques in the first section, the ions of interest are selected according to their mass and passed into the second section for optical spectroscopic studies. The trapped ions are excited by light from a laser and caused thereby to fluoresce. The fluorescent light emitted by the excited ions is reflected by the mirror and directed onto the detector. The AOD is scanned, and the photodetector output is recorded and analyzed. The ions remain in the second section for an extended period, enabling multiple studies to be carried out on the same ensemble of ions. 5 figs.

  16. Ion cyclotron resonance cell

    DOEpatents

    Weller, Robert R.

    1995-01-01

    An ion cyclotron resonance cell having two adjacent sections separated by a center trapping plate. The first section is defined by the center trapping plate, a first end trapping plate, and excitation and detector electrodes. The second section includes a second end trapping plate spaced apart from the center plate, a mirror, and an analyzer. The analyzer includes a wavelength-selective light detector, such as a detector incorporating an acousto-optical device (AOD) and a photodetector. One or more ion guides, grounded plates with holes for the ion beam, are positioned within the vacuum chamber of the mass spectrometer between the ion source and the cell. After ions are trapped and analyzed by ion cyclotron resonance techniques in the first section, the ions of interest are selected according to their mass and passed into the second section for optical spectroscopic studies. The trapped ions are excited by light from a laser and caused thereby to fluoresce. The fluorescent light emitted by the excited ions is reflected by the mirror and directed onto the detector. The AOD is scanned, and the photodetector output is recorded and analyzed. The ions remain in the second section for an extended period, enabling multiple studies to be carried out on the same ensemble of ions.

  17. Microfabricated ion trap array

    DOEpatents

    Blain, Matthew G.; Fleming, James G.

    2006-12-26

    A microfabricated ion trap array, comprising a plurality of ion traps having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale ion traps to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The reduced electrode voltage enables integration of the microfabricated ion trap array with on-chip circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of the microfabricated ion trap array can be realized in truly field portable, handheld microanalysis systems.

  18. Industrial ion source technology

    NASA Technical Reports Server (NTRS)

    Kaufman, H. R.

    1976-01-01

    A 30 cm electron bombardment ion source was designed and fabricated for micromachining and sputtering applications. This source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. An average ion current density of 1 ma/sq cm with 500 eV argon ions was selected as a design operating condition. The ion beam at this operating condition was uniform and well collimated, with an average variation of plus or minus 5 percent over the center 20 cm of the beam at distances up to 30 cm from the ion source. A variety of sputtering applications were undertaken with a small 10 cm ion source to better understand the ion source requirements in these applications. The results of these experimental studies are also included.

  19. 75 FR 25319 - Agency Information Collection (Survey of Satisfaction With the Disability Evaluation System (DES...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF VETERANS AFFAIRS Agency Information Collection (Survey of Satisfaction With the Disability Evaluation System (DES... Control No. 2900-New (DES).'' SUPPLEMENTARY INFORMATION: Title: Survey of Satisfaction with the...

  20. Modelisation des emissions de particules microniques et nanometriques en usinage

    NASA Astrophysics Data System (ADS)

    Khettabi, Riad

    La mise en forme des pieces par usinage emet des particules, de tailles microscopiques et nanometriques, qui peuvent etre dangereuses pour la sante. Le but de ce travail est d'etudier les emissions de ces particules pour fins de prevention et reduction a la source. L'approche retenue est experimentale et theorique, aux deux echelles microscopique et macroscopique. Le travail commence par des essais permettant de determiner les influences du materiau, de l'outil et des parametres d'usinage sur les emissions de particules. E nsuite un nouveau parametre caracterisant les emissions, nomme Dust unit , est developpe et un modele predictif est propose. Ce modele est base sur une nouvelle theorie hybride qui integre les approches energetiques, tribologiques et deformation plastique, et inclut la geometrie de l'outil, les proprietes du materiau, les conditions de coupe et la segmentation des copeaux. Il ete valide au tournage sur quatre materiaux: A16061-T6, AISI1018, AISI4140 et fonte grise.

  1. Charge exchange molecular ion source

    DOEpatents

    Vella, Michael C.

    2003-06-03

    Ions, particularly molecular ions with multiple dopant nucleons per ion, are produced by charge exchange. An ion source contains a minimum of two regions separated by a physical barrier and utilizes charge exchange to enhance production of a desired ion species. The essential elements are a plasma chamber for production of ions of a first species, a physical separator, and a charge transfer chamber where ions of the first species from the plasma chamber undergo charge exchange or transfer with the reactant atom or molecules to produce ions of a second species. Molecular ions may be produced which are useful for ion implantation.

  2. Problemes en enseignement fonctionnel des langues (Problems in the Functional Teaching of Languages). Publication B-103.

    ERIC Educational Resources Information Center

    Alvarez, Gerardo, Ed.; Huot, Diane, Ed.

    Articles include: (1) "L'elaboration du materiel pedagogique pour des publics adultes" (The Elaboration of Teaching Materials for the Adult Public) by G. Painchaud-Leblanc, (2) "L'elaboration d'un programme d'etudes en francais langue seconde a partir des donnees recentes en didactique des langues" (The Elaboration of a Program of Study in French…

  3. Atomic ion clock with two ion traps, and method to transfer ions

    NASA Technical Reports Server (NTRS)

    Prestage, John D. (Inventor); Chung, Sang K. (Inventor)

    2011-01-01

    An atomic ion clock with a first ion trap and a second ion trap, where the second ion trap is of higher order than the first ion trap. In one embodiment, ions may be shuttled back and forth from one ion trap to the other by application of voltage ramps to the electrodes in the ion traps, where microwave interrogation takes place when the ions are in the second ion trap, and fluorescence is induced and measured when the ions are in the first ion trap. In one embodiment, the RF voltages applied to the second ion trap to contain the ions are at a higher frequency than that applied to the first ion trap. Other embodiments are described and claimed.

  4. Ion Outflow Observations

    NASA Technical Reports Server (NTRS)

    Mellot, Mary (Technical Monitor)

    2002-01-01

    The characteristics of out-flowing ions have been investigated under various circumstances. In particular the upwelling of ions from the cleft region has been studied to attempt to look at source characteristics (e.g., temperature, altitude). High altitude (6-8 Re) data tend to show ions species that have the same velocity and are adiabatically cooled. Such ions, while representative of their source, can not provide an accurate picture. Ion observations from the TIDE detector on the Polar spacecraft show an energy (or equivalently a velocity) spectrum of ions as they undo the geomagnetic mass spectrometer effect due to convection-gravity separation of the different species. Consolidation of this type of data into a complete representation of the source spectrum can be attempted by building a set of maximum-phase-space- density-velocity pairs and attributing the total to the source.

  5. Ion photon emission microscope

    DOEpatents

    Doyle, Barney L.

    2003-04-22

    An ion beam analysis system that creates microscopic multidimensional image maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the ion-induced photons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted photons are collected in the lens system of a conventional optical microscope, and projected on the image plane of a high resolution single photon position sensitive detector. Position signals from this photon detector are then correlated in time with electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these photons initially.

  6. Ion-Solid Interactions

    NASA Astrophysics Data System (ADS)

    Nastasi, Michael; Mayer, James; Hirvonen, James K.

    2004-12-01

    Modern technology depends on materials with precisely controlled properties. Ion beams are an excellent way to achieve controlled modification of surface and near-surface regions. In every integrated circuit production line, for example, there are ion implantation systems. In addition to integrated circuit technology, ion beams can modify the mechanical, tribological, and chemical properties of metal, intermetallic, and ceramic materials without altering their bulk properties. Ion-solid interactions are the foundation that underlies the broad application of ion beams to the modification of materials. This text covers the fundamentals and applications of ion-solid interactions, and is aimed at graduate students and researchers interested in electronic devices, surface engineering, reactor and nuclear engineering, and materials science issues associated with metastable phase synthesis.

  7. HEAVY ION LINEAR ACCELERATOR

    DOEpatents

    Van Atta, C.M.; Beringer, R.; Smith, L.

    1959-01-01

    A linear accelerator of heavy ions is described. The basic contributions of the invention consist of a method and apparatus for obtaining high energy particles of an element with an increased charge-to-mass ratio. The method comprises the steps of ionizing the atoms of an element, accelerating the resultant ions to an energy substantially equal to one Mev per nucleon, stripping orbital electrons from the accelerated ions by passing the ions through a curtain of elemental vapor disposed transversely of the path of the ions to provide a second charge-to-mass ratio, and finally accelerating the resultant stripped ions to a final energy of at least ten Mev per nucleon.

  8. [And Sarah Félix created "L 'Eau des Fées" and "La Parfumerie des Fées"].

    PubMed

    Raynal, Cécile

    2015-12-01

    century, the parisian perfumery of Sarah Felix was famous especially for her cosmetic "L'Eau des Fées" ("Water of the Fairies"), a dyeing supposed to give back to the old hair the color of their youth. Sarah Felix, sister of the famous actress Rachel, exercised several jobs before becoming perfumer. At first, she was actress, then she tried ... oyster culture in Normandy ! Abandoning these activities, Sarah Felix became really a businesswoman in Paris. She dedicated herself to perfumery, in particular to "L'Eau des Fées", from 1866. To launch its product, she was associated to competency characters (engineer, pharmacist, physician) and benefited from the protection of the imperial family. A lawsuit between the associates and the 1870 war hindered the company's early days, but "L'Eau des Fées" provided with quality pledges, imposed itself definitely. The "Parfumerie des Fées" completed the range of its cosmetics with creams, powders, etc. Sarah Félix paid attention to present "L'Eau des Fées" as a dye devoid of toxicity. Was it really the case and could il be sold nowadays? These two issues are discussed in the last part. PMID:26827551

  9. [And Sarah Félix created "L 'Eau des Fées" and "La Parfumerie des Fées"].

    PubMed

    Raynal, Cécile

    2015-12-01

    century, the parisian perfumery of Sarah Felix was famous especially for her cosmetic "L'Eau des Fées" ("Water of the Fairies"), a dyeing supposed to give back to the old hair the color of their youth. Sarah Felix, sister of the famous actress Rachel, exercised several jobs before becoming perfumer. At first, she was actress, then she tried ... oyster culture in Normandy ! Abandoning these activities, Sarah Felix became really a businesswoman in Paris. She dedicated herself to perfumery, in particular to "L'Eau des Fées", from 1866. To launch its product, she was associated to competency characters (engineer, pharmacist, physician) and benefited from the protection of the imperial family. A lawsuit between the associates and the 1870 war hindered the company's early days, but "L'Eau des Fées" provided with quality pledges, imposed itself definitely. The "Parfumerie des Fées" completed the range of its cosmetics with creams, powders, etc. Sarah Félix paid attention to present "L'Eau des Fées" as a dye devoid of toxicity. Was it really the case and could il be sold nowadays? These two issues are discussed in the last part.

  10. Collection of ions

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore; Bounds, John Alan; Koster, James E.

    2001-01-01

    The apparatus and method provide an improved technique for detecting ions as the area from which ions are attracted to a detector is increased, consequently increasing the number of ions detected. This is achieved by providing the outer electrodes of the detector connected to the electrical potential, together with alternate intermediate electrodes. The other intermediate electrodes and preferably the housing are grounded. The technique renders such detection techniques more sensitive and gives them a lower threshold at which they can function.

  11. ION ACCELERATION SYSTEM

    DOEpatents

    Luce, J.S.; Martin, J.A.

    1960-02-23

    Well focused, intense ion beams are obtained by providing a multi- apertured source grid in front of an ion source chamber and an accelerating multi- apertured grid closely spaced from and in alignment with the source grid. The longest dimensions of the elongated apertures in the grids are normal to the direction of the magnetic field used with the device. Large ion currents may be withdrawn from the source, since they do not pass through any small focal region between the grids.

  12. Neutron ion temperature measurement

    SciTech Connect

    Strachan, J.D.; Hendel, H.W.; Lovberg, J.; Nieschmidt, E.B.

    1986-11-01

    One important use of fusion product diagnostics is in the determination of the deuterium ion temperature from the magnitude of the 2.5 MeV d(d,n)/sup 3/He neutron emission. The detectors, calibration methods, and limitations of this technique are reviewed here with emphasis on procedures used at PPPL. In most tokamaks, the ion temperature deduced from neutrons is in reasonable agreement with the ion temperature deduced by other techniques.

  13. APPARATUS FOR HEATING IONS

    DOEpatents

    Chambers, E.S.; Garren, A.A.; Kippenhan, D.O.; Lamb, W.A.S.; Riddell, R.J. Jr.

    1960-01-01

    The heating of ions in a magnetically confined plasma is accomplished by the application of an azimuthal radiofrequency electric field to the plasma at ion cyclotron resonance. The principal novelty resides in the provision of an output tank coil of a radiofrequency driver to induce the radiofrequency field in the plasma and of electron current bridge means at the ends of the plasma for suppressing radial polarization whereby the radiofrequency energy is transferred to the ions with high efficiency.

  14. Ion beam generating apparatus

    DOEpatents

    Brown, I.G.; Galvin, J.

    1987-12-22

    An ion generating apparatus utilizing a vacuum chamber, a cathode and an anode in the chamber. A source of electrical power produces an arc or discharge between the cathode and anode. The arc is sufficient to vaporize a portion of the cathode to form a plasma. The plasma is directed to an extractor which separates the electrons from the plasma, and accelerates the ions to produce an ion beam. 10 figs.

  15. Restauration adaptative des contours par une approche inspiree de la prediction des performances

    NASA Astrophysics Data System (ADS)

    Rousseau, Kami

    En teledetection, les cartes de contours peuvent servir, entre autres choses, a la restitution geometrique, a la recherche d'elements lineaires, ainsi qu'a la segmentation. La creation de ces cartes est faite relativement tot dans la chaine de traitements d'une image. Pour assurer la qualite des operations subsequentes, il faut veiller a obtenir une carte de contours precise. Notre problematique est de savoir s'il est possible de diminuer la perte de temps liee au choix d'algorithme et de parametre en corrigeant automatiquement la carte de contours. Nous concentrerons donc nos efforts sur le developpement d'une methode de detection/restauration de contours adaptative. Notre methode s'inspire d'une technique de prediction des performances d'algorithmes de bas niveau. Elle consiste a integrer un traitement par reseau de neurones a une methode " classique " de detection de contours. Plus precisement, nous proposons de combiner la carte de performances avec la carte de gradient pour permettre des decisions plus exactes. La presente etude a permis de developper un logiciel comprenant un reseau de neurones entraine pour predire la presence de contours. Ce reseau de neurones permet d'ameliorer les decisions de detecteurs de contours, en reduisant le nombre de pixels de fausses alarmes et de contours manques. La premiere etape de ce travail consiste en une methode d'evaluation de performance pour les cartes de contours. Une fois ce choix effectue, il devient possible de comparer les cartes entre elles. Il est donc plus aise de determiner, pour chaque image, la meilleure detection de contours. La revue de la litterature realisee simultanement a permis de faire un choix d'un groupe d'indicateurs prometteurs pour la restauration de contours. Ces derniers ont servi a la calibration et a l'entrainement d'un reseau de neurones pour modeliser les contours. Par la suite, l'information fournie par ce reseau a ete combinee par multiplication arithmetique avec les cartes d

  16. Ion trap device

    DOEpatents

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  17. Ion thrusting system

    NASA Technical Reports Server (NTRS)

    Hartley, Frank T. (Inventor)

    2007-01-01

    An ion thrusting system is disclosed comprising an ionization membrane having at least one area through which a gas is passed, and which ionizes the gas molecules passing therethrough to form ions and electrons, and an accelerator element which accelerates the ions to form thrust. In some variations, a potential is applied to the ionization membrane may be reversed to thrust ions in an opposite direction. The ionization membrane may also include an opening with electrodes that are located closer than a mean free path of the gas being ionized. Methods of manufacture and use are also provided.

  18. Correlation ion mobility spectroscopy

    DOEpatents

    Pfeifer, Kent B.; Rohde, Steven B.

    2008-08-26

    Correlation ion mobility spectrometry (CIMS) uses gating modulation and correlation signal processing to improve IMS instrument performance. Closely spaced ion peaks can be resolved by adding discriminating codes to the gate and matched filtering for the received ion current signal, thereby improving sensitivity and resolution of an ion mobility spectrometer. CIMS can be used to improve the signal-to-noise ratio even for transient chemical samples. CIMS is especially advantageous for small geometry IMS drift tubes that can otherwise have poor resolution due to their small size.

  19. Cardiac ion channels

    PubMed Central

    Priest, Birgit T; McDermott, Jeff S

    2015-01-01

    Ion channels are critical for all aspects of cardiac function, including rhythmicity and contractility. Consequently, ion channels are key targets for therapeutics aimed at cardiac pathophysiologies such as atrial fibrillation or angina. At the same time, off-target interactions of drugs with cardiac ion channels can be the cause of unwanted side effects. This manuscript aims to review the physiology and pharmacology of key cardiac ion channels. The intent is to highlight recent developments for therapeutic development, as well as elucidate potential mechanisms for drug-induced cardiac side effects, rather than present an in-depth review of each channel subtype. PMID:26556552

  20. Ion beam accelerator system

    NASA Technical Reports Server (NTRS)

    Aston, G. (Inventor)

    1981-01-01

    A system is described that combines geometrical and electrostatic focusing to provide high ion extraction efficiency and good focusing of an accelerated ion beam. The apparatus includes a pair of curved extraction grids with multiple pairs of aligned holes positioned to direct a group of beamlets along converging paths. The extraction grids are closely spaced and maintained at a moderate potential to efficiently extract beamlets of ions and allow them to combine into a single beam. An accelerator electrode device downstream from the extraction grids is at a much lower potential than the grids to accelerate the combined beam. The application of the system to ion implantation is mentioned.

  1. Peristaltic ion source

    SciTech Connect

    Brown, I.G.; Anders, A.; Anders, S.; Dickinson, M.R.; MacGill, R.A.

    1995-08-01

    Conventional ion sources generate energetic ion beams by accelerating the plasma-produced ions through a voltage drop at the extractor, and since it is usual that the ion beam is to propagate in a space which is at ground potential, the plasma source is biased at extractor voltage. For high ion beam energy the plasma source and electrical systems need to be raised to high voltage, a task that adds considerable complexity and expense to the total ion source system. The authors have developed a system which though forming energetic ion beams at ground potential as usual, operates with the plasma source and electronics at ground potential also. Plasma produced by a nearby source streams into a grided chamber that is repetitively pulsed from ground to high positive potential, sequentially accepting plasma into its interior region and ejecting it energetically. They call the device a peristaltic ion source. In preliminary tests they`ve produced nitrogen and titanium ion beams at energies from 1 to 40 keV. Here they describe the philosophy behind the approach, the test embodiment that they have made, and some preliminary results.

  2. Ion beam thruster shield

    NASA Technical Reports Server (NTRS)

    Power, J. L. (Inventor)

    1976-01-01

    An ion thruster beam shield is provided that comprises a cylindrical housing that extends downstream from the ion thruster and a plurality of annular vanes which are spaced along the length of the housing, and extend inwardly from the interior wall of the housing. The shield intercepts and stops all charge exchange and beam ions, neutral propellant, and sputter products formed due to the interaction of beam and shield emanating from the ion thruster outside of a fixed conical angle from the thruster axis. Further, the shield prevents the sputter products formed during the operation of the engine from escaping the interior volume of the shield.

  3. Heparin enhances the catalytic activity of des-ETW-thrombin.

    PubMed

    Goodwin, C A; Deadman, J J; Le Bonniec, B F; Elgendy, S; Kakkar, V V; Scully, M F

    1996-04-01

    The thrombin mutant, des-ETW-thrombin, lacking Glu(146), Thr(147), and Trp(148) within a unique insertion loop located at the extreme end of the primary specificity pocket, has been shown previously to exhibit reduced catalytic activity with respect to macromolecular and synthetic thrombin substrates and reduced or enhanced susceptibility to inhibition. Investigation of the hydrolysis of peptidyl p-nitroanilide substrates by des-ETW-thrombin showed increased activity in the presence of heparin and other sulphated glycosaminoglycans. No effect was observed upon the activity of wild-type thrombin. Heparin was found to decrease the K(m) for cleavage of four thrombin-specific substrates by des-ETW-thrombin by 3-4-fold. Similarly, pentosan polysulphate (PPS) decreased the K(m) with these substrates by 8-10-fold. Heparin also increased the rate of inhibition of des-ETW-thrombin by antithrombin III and D-phenylalanyl-prolyl-arginylchloromethane (PPACK). The inhibition of des-ETW-thrombin by a number of thrombin-specific peptide boronic acids also showed significant reduction in the final K(i) in the presence of heparin, due to reduction in the off-rate. A peptide analogue of a sequence of hirudin which binds thrombin tightly to exosite I (fibrinogen recognition site) potentiated the activity of des-ETW-thrombin against peptide p-nitroanilide substrates in a manner similar to heparin. The K(i) for the inhibition of des-ETW-thrombin by p-aminobenzamidine was decreased by these ligands from 9.7 mM to 7.5 mM, 5.1 mM, and 2.5 mM in the presence of heparin, hirudin peptide and PPS respectively, suggesting the increased catalytic activity is due to enhanced access to the primary specificity pocket. The positive influence of these ligands on des-ETW-thrombin was reversed in the presence of ATP or ADP; the latter has previously been shown to inhibit thrombin activity by blocking initial interaction with fibrinogen at exosite 1. Because the effect of heparin and PPS is similar to

  4. Halide Ion Enhancement of Nitrate Ion Photolysis

    NASA Astrophysics Data System (ADS)

    Richards, N. K.; Wingen, L. M.; Callahan, K. M.; Tobias, D. J.; Finlayson-Pitts, B. J.

    2009-12-01

    Nitrate ion photochemistry is an important source of NOx in the polar regions. It is uncertain whether coexisting ions such as halides play a role in nitrate photochemistry. The effect of halides on NO3 photolysis was investigated using photolysis experiments in 230 L Teflon chambers that contain deliquesced aerosols of NaBr:NaNO3, KBr:KNO3 and ternary mixtures of NaCl:NaBr:NaNO3. Gas phase NO2 and gaseous halogen products were measured as a function of photolysis time using long path FTIR, NOx chemiluminescence and API-MS (atmospheric pressure ionization mass spectrometry). Experiments were conducted with NO3- held at a constant 0.5 M and with the amount of total halide concentration varying from 0.25 M to 4 M. Studies on NaBr:NaNO3 mixtures suggest that as the bromide ion to nitrate ion ratio increases, there is an enhancement in the rate of production of NO2 in the nitrate-bromide mixtures over that formed in the photolysis of NaNO3. Molecular dynamic (MD) simulations provide molecular level insight into the ions near the air-water interface in the aqueous halide-nitrate mixtures. These studies suggest that the presence of sodium halides at the air-water interface may encourage some nitrate ions to approach the top layers of water, allowing for more efficient escape of photoproducts than is seen in the absence of halides. Experiments on mixtures of KBr:KNO3 are being conducted to determine potential cation effects. In addition, ternary mixtures of NaCl:NaBr:NaNO3 are being examined to determine the effects of mixtures of halides on production of NO2 and gaseous halogen products. The implications of this photochemistry for tropospheric chemistry will be discussed.

  5. Comparison des donnees simulees des capteurs de SPOT et landsat-D: Application a une region agricole

    NASA Astrophysics Data System (ADS)

    Saint, Gilbert; Podaire, Alain

    La modélisation de la luminance spectrale des objets observés en télédétection permet d'effectuer des simulations de différents capteurs à partir de données obtenues au moyen d'un scanneur DAEDALUS aéroporté : les qualités radiométrique et géométrique ont pu être évaluées par une comparaison avec des données Landsat réelles. L'analyse sur une zone agricole met surtout en évidence le rôle important de l'accroissement de la résolution.

  6. Analyse des facteurs prédictifs de malignité des goitres nodulaires : à propos de 500 cas

    PubMed Central

    Bouaity, Brahim; Darouassi, Youssef; Chihani, Mehdi; Touati, Mohamed Mliha; Ammar, Haddou

    2016-01-01

    Les nodules thyroïdiens sont très fréquents et moins de 10% d'entre eux sont malin. Ils posent un véritable problème diagnostique et thérapeutique surtout par rapport à leur nature bénigne ou maligne. L’étude de certains facteurs cliniques et paracliniques de présomption de malignité permet de bien codifier la stratégie thérapeutique. Le but de ce travail est d’étudier les facteurs prédictifs de malignité des goitres nodulaires et comparer nos résultats à ceux de la littérature. Il s'agit d'une étude rétrospective à propos de 500 cas de goitres nodulaires opérés au service d'Oto-rhino-laryngologie (ORL) et Chirurgie cervico-faciale (CCF) de l'hôpital militaire Avicenne de Marrakech entre 2006 et 2012. Le pourcentage de cancers a été de 6,8%. L’âge moyen de nos patients était de 46 ans, avec une sex-ratio de 5 (F/H). A la palpation cervicale; le caractère dure du nodule a été constaté dans 94,4% des cas de cancer, avec des limites irrégulières dans 64,70% des cas de cancer. Trois nodules étaient fixes et ils étaient tous malins. Les adénopathies cervicales ont été constatées chez 8 malades dont 7 présentaient des cancers. A l’échographie, 61,8% des nodules malins présentaient un aspect hypoéchogène, avec des contours flous dans 88,24% des cas. La vascularisation intra nodulaire était présente dans 35,3% de ces cas des cancers avec des microcalcifications chez 55,9% d'entre eux. Le halo hypoéchogene périnodulaire était incomplet dans 73,5% des cas de cancer. Nos patients étaient en euthyroïdie dans 84,6% des cas. Les facteurs prédictifs de malignité d'un goitre nodulaire, étaient donc dans notre étude d'abord cliniques: l’âge supérieur à 60 ans, la consistance dure du nodule, sa fixité, son caractère irrégulier et mal limité à la palpation, ainsi que la présence d'adénopathie(s) cervicale(s) à l'examen; et échographiques: le caractère hypoéchogène, les limites floues, la présence de

  7. Cold Strontium Ion Source for Ion Interferometry

    NASA Astrophysics Data System (ADS)

    Jackson, Jarom; Durfee, Dallin

    2015-05-01

    We are working on a cold source of Sr Ions to be used in an ion interferometer. The beam will be generated from a magneto-optical trap (MOT) of Sr atoms by optically ionizing atoms leaking out a carefully prepared hole in the MOT. A single laser cooling on the resonant transition (461 nm) in Sr should be sufficient for trapping, as we've calculated that losses to the atom beam will outweigh losses to dark states. Another laser (405 nm), together with light from the trapping laser, will drive a two photon transition in the atom beam to an autoionizing state. Supported by NSF Award No. 1205736.

  8. Mercury ion thruster technology

    NASA Technical Reports Server (NTRS)

    Beattie, J. R.; Matossian, J. N.

    1989-01-01

    The Mercury Ion Thruster Technology program was an investigation for improving the understanding of state-of-the-art mercury ion thrusters. Emphasis was placed on optimizing the performance and simplifying the design of the 30 cm diameter ring-cusp discharge chamber. Thruster performance was improved considerably; the baseline beam-ion production cost of the optimized configuration was reduced to Epsilon (sub i) perspective to 130 eV/ion. At a discharge propellant-utilization efficiency of 95 percent, the beam-ion production cost was reduced to about 155 eV/ion, representing a reduction of about 40 eV/ion over the corresponding value for the 30 cm diameter J-series thruster. Comprehensive Langmuir-probe surveys were obtained and compared with similar measurements for a J-series thruster. A successful volume-averaging scheme was developed to correlate thruster performance with the dominant plasma processes that prevail in the two thruster designs. The average Maxwellian electron temperature in the optimized ring-cusp design is as much as 1 eV higher than it is in the J-series thruster. Advances in ion-extraction electrode fabrication technology were made by improving materials selection criteria, hydroforming and stress-relieving tooling, and fabrications procedures. An ion-extraction performance study was conducted to assess the effect of screen aperture size on ion-optics performance and to verify the effectiveness of a beam-vectoring model for three-grid ion optics. An assessment of the technology readiness of the J-series thruster was completed, and operation of an 8 cm IAPS thruster using a simplified power processor was demonstrated.

  9. Classification of DES16C2nm as a SLSN at z=1.998

    NASA Astrophysics Data System (ADS)

    Galbany, L.; D'Andrea, C.; Prajs, S.; Smith, M.; Sullivan, M.; Ponder, K.; Gonzalez-Gaitan, S.; Forster, F.; Hamuy, M.; Prieto, Jose Luis; Schubnell, M.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; Gladney, L.; March, M.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.; Macaulay, E.; Nichol, R.; Childress, M.; Maartens, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Gupta, R.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Foley, R. J.; Pan, Y.-C.; Casas, R.; Castander, F. J.; Papadopoulos, A.; Morganson, E.; Desai, S.; Paech, K.; Smith, R. C.

    2016-11-01

    We report the spectroscopic classification of DES16C2nm as a superluminous supernova (SLSN) discovered by the Dark Energy Survey (ATEL #4668). DES16C2nm was discovered in the first epoch of DES Y4, on 22 August 2016 at R.A. = 03:40:14.83, Decl = -29:05:53.5 with i = 23.2 mag. DES16C2nm has a non-detection in the final epoch of DES Y3 on 08 February 2016.

  10. Fluorescence de 0,8 à 1,7 μpm de fibres optiques en silice dopées par l'ion Cr^{4+}

    NASA Astrophysics Data System (ADS)

    Dussardier, B.; Guyot, Y.; Felice, V.; Monnom, G.; Boulon, G.

    2002-06-01

    La luminescence des ions Cr^{4+} dans les fibres optiques en silice est très sensible à la concentration, à la composition du matériau et aux conditions d'excitation. Nous caractérisons ici la luminescence dans le proche infrarouge (IR), de 800 à 1700 nm, résolue dans le temps, de préformes pour fibres optiques réalisées par MCVD. Nous discutons l'intérêt de telles fibres pour le domaine des télécommunications.

  11. Metal Ions in Unusual Valency States.

    ERIC Educational Resources Information Center

    Sellers, Robin M.

    1981-01-01

    Discusses reactivity of metal ions with the primary products of water radiolysis, hyper-reduced metal ions, zero-valent metal ions, unstable divalent ions from the reduction of bivalent ions, hyper-oxidized metal ions, and metal complexes. (CS)

  12. Transport de paires EPR dans des structures mesoscopiques

    NASA Astrophysics Data System (ADS)

    Dupont, Emilie

    Dans cette these, nous nous sommes particulierement interesses a la propagation de paires EPR1 delocalisees et localisees, et a l'influence d'un supraconducteur sur le transport de ces paires. Apres une introduction de cette etude, ainsi que du cadre scientifique qu'est l'informatique quantique dans lequel elle s'inscrit, nous allons dans le chapitre 1 faire un rappel sur le systeme constitue de deux points quantiques normaux entoures de deux fils supraconducteurs. Cela nous permettra d'introduire une methode de calcul qui sera reutilisee par la suite, et de trouver egalement le courant Josephson produit par ce systeme transforme en SQUID-dc par l'ajout d'une jonction auxiliaire. Le SQUID permet de mesurer l'etat de spin (singulet ou triplet), et peut etre forme a partir d'autres systemes que nous etudierons ensuite. Dans le chapitre 2, nous rappellerons l'etude detaillee d'un intricateur d'Andreev faite par un groupe de Bale. La matrice T, permettant d'obtenir le courant dans les cas ou les electrons sont separes spatialement ou non, sera etudiee en detail afin d'en faire usage au chapitre suivant. Le chapitre 3 est consacre a l'etude de l'influence du bruit sur le fonctionnement de l'intricateur d'Andreev. Ce bruit modifie la forme du courant jusqu'a aboutir a d'autres conditions de fonctionnement de l'intricateur. En effet, le bruit present sur les points quantiques peut perturber le transport des paires EPR par l'intermediaire des degres de liberte. Nous montrerons que, du fait de l'"intrication" entre la charge de la paire et le bruit, la paire est detruite pour des temps longs. Cependant, le resultat le plus important sera que le bruit perturbe plus le transport des paires delocalisees, qui implique une resonance de Breit-Wigner a deux particules. Le transport parasite n'implique pour sa part qu'une resonance de Breit-Wigner a une particule. Dans le chapitre 4, nous reviendrons au systeme constitue de deux points quantiques entoures de deux fils

  13. Opération multimode transverse des OPOs: des structures classiques aux corrélations quantiques

    NASA Astrophysics Data System (ADS)

    Martinelli, M.; Ducci, S.; Gigan, S.; Treps, N.; Maître, A.; Fabre, C.

    2002-06-01

    Nous démontrons la formation de structures transverses sur les faisceaux émis par un oscillateur paramétrique optique (OPO) de type II en configuration confocale. D'un point de vue classique nous mettons en évidence le caractère multimode transverse de telles structures. A travers l'étude des corrélations spatiales des faisceaux générés nous montrons que ces structures sont également multimodes d'un point de vue quantique.

  14. Apport des moyens endoscopiques dans la dilatation des sténoses caustiques de l’œsophage

    PubMed Central

    Seydou, Togo; Abdoulaye, Ouattara Moussa; xing, Li; Zi, Sanogo Zimogo; sekou, Koumaré; Wen, Yang Shang; Ibrahim, Sankare; Sekou, Toure Cheik Ahmed; Boubacar, Maiga Ibrahim; Saye, Jacque; Jerome, Dakouo Dodino; Dantoumé, Toure Ousmane; Sadio, Yena

    2016-01-01

    Introduction Toutes les sténoses symptomatiques de l’œsophage peuvent être dilatées par voie endoscopique. Nous évaluons l'apport des moyens endoscopiques dans la prise en charge de la dilatation œsophagienne pour sténose caustique de l’œsophage (SCO) au Mali. Méthodes IL s'agissait d'une étude descriptive et prospective réalisée dans le service de chirurgie thoracique à l'hôpital du Mali. Au total 46 dossiers cliniques de patients on été enregistrés et subdivisés en 4 groupes en fonction de la topographie des lésions cicatricielles. Le nombre de cas d'assistance endoscopique réalisé a été déterminé afin de comprendre l'apport des moyens endoscopiques dans le succès de la dilatation des SCO. Pour les 2 différentes méthodes de dilatation utilisées, le résultat du traitement et le coût ont comparés. Résultats La FOGD a été utilisée dans 19 cas (41.30%) de dilatation avec la bougie de Savary Guillard et dans 47.82% des cas dans la dilatation de Lerut. La vidéo-laryngoscopie a été utilisé 58.69% des cas de dilatation à la bougie de Lerut. Le passage de guide métallique et / ou de fil-guide a été réalisée dans 39.13% avec la vidéo laryngoscopie et dans 58.68% avec la FOGD. Dans la comparaison des deux méthodes, il existe une différence significative dans la survenue des complications (p=0.04075), l'anesthésie générale (p=0.02287), l'accessibilité à la méthode (p=0.04805) et la mortalité (p=0.00402). Conclusion La SCO est une pathologie grave et sous évaluée au Mali. Les moyens endoscopiques contribuent considérablement au succès de la dilatation œsophagienne pour sténose caustique dans les différentes méthodes utilisées. PMID:27200129

  15. Ion-Selective Electrodes.

    ERIC Educational Resources Information Center

    Arnold, Mark A.; Meyerhoff, Mark E.

    1984-01-01

    Literature on ion-selective electrodes (ISEs) is reviewed in seven sections: books, conferences, reviews; potentiometric membrane electrodes; glass and solid-state membrane electrodes; liquid and polymer membrane ISEs; coated wire electrodes, ion-selective field effect transistors, and microelectrodes; gas sensors and selective bioelectrode…

  16. Selective ion source

    DOEpatents

    Leung, K.N.

    1996-05-14

    A ion source is described wherein selected ions maybe extracted to the exclusion of unwanted ion species of higher ionization potential. Also described is a method of producing selected ions from a compound, such as P{sup +} from PH{sub 3}. The invention comprises a plasma chamber, an electron source, a means for introducing a gas to be ionized by electrons from the electron source, means for limiting electron energy from the electron source to a value between the ionization energy of the selected ion species and the greater ionization energy of an unwanted ion specie, and means for extracting the target ion specie from the plasma chamber. In one embodiment, the electrons are generated in a plasma cathode chamber immediately adjacent to the plasma chamber. A small extractor draws the electrons from the plasma cathode chamber into the relatively positive plasma chamber. The energy of the electrons extracted in this manner is easily controlled. The invention is particularly useful for doping silicon with P{sup +}, As{sup +}, and B{sup +} without the problematic presence of hydrogen, helium, water, or carbon oxide ions. Doped silicon is important for manufacture of semiconductors and semiconductor devices. 6 figs.

  17. Microfabricated cylindrical ion trap

    DOEpatents

    Blain, Matthew G.

    2005-03-22

    A microscale cylindrical ion trap, having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale cylindrical ion trap to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The microscale CIT has a reduced ion mean free path, allowing operation at higher pressures with less expensive and less bulky vacuum pumping system, and with lower battery power than conventional- and miniature-sized ion traps. The reduced electrode voltage enables integration of the microscale cylindrical ion trap with on-chip integrated circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of microscale cylindrical ion traps can be realized in truly field portable, handheld microanalysis systems.

  18. Selective ion source

    DOEpatents

    Leung, Ka-Ngo

    1996-01-01

    A ion source is described wherein selected ions maybe extracted to the exclusion of unwanted ion species of higher ionization potential. Also described is a method of producing selected ions from a compound, such as P.sup.+ from PH.sub.3. The invention comprises a plasma chamber, an electron source, a means for introducing a gas to be ionized by electrons from the electron source, means for limiting electron energy from the electron source to a value between the ionization energy of the selected ion species and the greater ionization energy of an unwanted ion specie, and means for extracting the target ion specie from the plasma chamber. In one embodiment, the electrons are generated in a plasma cathode chamber immediately adjacent to the plasma chamber. A small extractor draws the electrons from the plasma cathode chamber into the relatively positive plasma chamber. The energy of the electrons extracted in this manner is easily controlled. The invention is particularly useful for doping silicon with P.sup.+, AS.sup.+, and B.sup.+ without the problematic presence of hydrogen, helium, water, or carbon oxide ions. Doped silicon is important for manufacture of semiconductors and semiconductor devices.

  19. Ion Induction Accelerators

    NASA Astrophysics Data System (ADS)

    Barnard, John J.; Horioka, Kazuhiko

    The description of beams in RF and induction accelerators share many common features. Likewise, there is considerable commonality between electron induction accelerators (see Chap. 7) and ion induction accelerators. However, in contrast to electron induction accelerators, there are fewer ion induction accelerators that have been operated as application-driven user facilities. Ion induction accelerators are envisioned for applications (see Chap. 10) such as Heavy Ion Fusion (HIF), High Energy Density Physics (HEDP), and spallation neutron sources. Most ion induction accelerators constructed to date have been limited scale facilities built for feasibility studies for HIF and HEDP where a large numbers of ions are required on target in short pulses. Because ions are typically non-relativistic or weakly relativistic in much of the machine, space-charge effects can be of crucial importance. This contrasts the situation with electron machines, which are usually strongly relativistic leading to weaker transverse space-charge effects and simplified longitudinal dynamics. Similarly, the bunch structure of ion induction accelerators relative to RF machines results in significant differences in the longitudinal physics.

  20. Ion-beam technologies

    SciTech Connect

    Fenske, G.R.

    1993-01-01

    This compilation of figures and diagrams reviews processes for depositing diamond/diamond-like carbon films. Processes addressed are chemical vapor deposition (HFCVD, PACVD, etc.), plasma vapor deposition (plasma sputtering, ion beam sputtering, evaporation, etc.), low-energy ion implantation, and hybrid processes (biased sputtering, IBAD, biased HFCVD, etc.). The tribological performance of coatings produced by different means is discussed.

  1. Ion bombardment of Europa

    NASA Astrophysics Data System (ADS)

    Cassidy, Timothy A.; Paranicas, C.; Hendrix, A.; Johnson, R. E.

    2010-10-01

    The spectral difference between Europa's leading and trailing hemispheres has long been explained as a result of magnetospheric bombardment. A closer look at the longitudinal variation of ultraviolet spectral features reveals, however, that several processes, both exogenic and endogenic, are operating on the surface (Hendrix et al., 2010, submitted; Dalton et al., 2010, in preparation). Even magnetospheric bombardment can produce a variety of exogenic patterns; each "population” of particles has a distinct bombardment pattern. Work is ongoing to connect exogenic and spectral patterns. Here we describe one piece of that ongoing work, the calculation of ion bombardment and sputtering rates. We calculated the ion bombardment rate using a program that traces ion motion given the magnetic and electric fields in the vicinity of Europa's orbit, along with information on ion composition and energies from the Voyager and Galileo missions. We conclude that the vast majority of sulfur ions impact Europa's trailing hemisphere, while the sputtering rate is more uniform, in qualitative agreement with previous work. Overall, we find that the sputtering rate at the trailing hemisphere apex (where ion flux peaks) is about 3 times that at the leading hemisphere apex. This likely results in a net erosion of Europa's entire surface, not, as some have suggested, a net deposition of ice onto the leading hemisphere. We also conclude that the energetic ion flux peaks at Europa's poles, though the sputtering rate still peaks at the equatorial trailing hemisphere apex, where the combined sputtering by "cold” and "suprathermal” ions is highest.

  2. Ion mobility sensor system

    DOEpatents

    Xu, Jun; Watson, David B.; Whitten, William B.

    2013-01-22

    An ion mobility sensor system including an ion mobility spectrometer and a differential mobility spectrometer coupled to the ion mobility spectrometer. The ion mobility spectrometer has a first chamber having first end and a second end extending along a first direction, and a first electrode system that generates a constant electric field parallel to the first direction. The differential mobility spectrometer includes a second chamber having a third end and a fourth end configured such that a fluid may flow in a second direction from the third end to the fourth end, and a second electrode system that generates an asymmetric electric field within an interior of the second chamber. Additionally, the ion mobility spectrometer and the differential mobility spectrometer form an interface region. Also, the first end and the third end are positioned facing one another so that the constant electric field enters the third end and overlaps the fluid flowing in the second direction.

  3. Mechanically Activated Ion Channels

    PubMed Central

    Ranade, Sanjeev S.; Syeda, Ruhma; Patapoutian, Ardem

    2015-01-01

    Mechanotransduction, the conversion of physical forces into biochemical signals, is an essential component of numerous physiological processes including not only conscious senses of touch and hearing, but also unconscious senses such as blood pressure regulation. Mechanically activated (MA) ion channels have been proposed as sensors of physical force, but the identity of these channels and an understanding of how mechanical force is transduced has remained elusive. A number of recent studies on previously known ion channels along with the identification of novel MA ion channels have greatly transformed our understanding of touch and hearing in both vertebrates and invertebrates. Here, we present an updated review of eukaryotic ion channel families that have been implicated in mechanotransduction processes and evaluate the qualifications of the candidate genes according to specified criteria. We then discuss the proposed gating models for MA ion channels and highlight recent structural studies of mechanosensitive potassium channels. PMID:26402601

  4. ION PULSE GENERATION

    DOEpatents

    King, R.F.; Moak, C.D.; Parker, V.E.

    1960-10-11

    A device for generating ions in an ion source, forming the ions into a stream, deflecting the stream rapidly away from and back to its normal path along the axis of a cylindrical housing, and continually focusing the stream by suitable means into a sharp, intermittent beam along the axis is described. The beam exists through an axial aperture into a lens which focuses it into an accelerator tube. The ions in each burst are there accelerated to very high energies and are directed against a target placed in the high-energy end of the tube. Radiations from the target can then be analyzed in the interval between incidence of the bursts of ions on the target.

  5. Laser ion source for high brightness heavy ion beam

    NASA Astrophysics Data System (ADS)

    Okamura, M.

    2016-09-01

    A laser ion source is known as a high current high charge state heavy ion source. However we place great emphasis on the capability to realize a high brightness ion source. A laser ion source has a pinpoint small volume where materials are ionized and can achieve quite uniform low temperature ion beam. Those features may enable us to realize very small emittance beams. In 2014, a low charge state high brightness laser ion source was successfully commissioned in Brookhaven National Laboratory. Now most of all the solid based heavy ions are being provided from the laser ion source for regular operation.

  6. Simulations of the OzDES AGN reverberation mapping project

    SciTech Connect

    King, Anthea L.; Martini, Paul; Davis, Tamara M.; Denney, K. D.; Kochanek, C. S.; Peterson, Bradley M.; Skielboe, Andreas; Vestergaard, Marianne; Huff, Eric; Watson, Darach; Banerji, Manda; McMahon, Richard; Sharp, Rob; Lidman, C.

    2015-08-26

    As part of the Australian spectroscopic dark energy survey (OzDES) we are carrying out a large-scale reverberation mapping study of ~500 quasars over five years in the 30 deg2 area of the Dark Energy Survey (DES) supernova fields. These quasars have redshifts ranging up to 4 and have apparent AB magnitudes between 16.8 mag < r < 22.5 mag. The aim of the survey is to measure time lags between fluctuations in the quasar continuum and broad emission-line fluxes of individual objects in order to measure black hole masses for a broad range of active galactic nuclei (AGN) and constrain the radius–luminosity (R–L) relationship. Here we investigate the expected efficiency of the OzDES reverberation mapping campaign and its possible extensions. We expect to recover lags for ~35–45 % of the quasars. AGN with shorter lags and greater variability are more likely to yield a lag measurement, and objects with lags ≲6 months or ~1 yr are expected to be recovered the most accurately. The baseline OzDES reverberation mapping campaign is predicted to produce an unbiased measurement of the R–L relationship parameters for Hβ, MgIIλ2798, and C IVλ1549. As a result, extending the baseline survey by either increasing the spectroscopic cadence, extending the survey season, or improving the emission-line flux measurement accuracy will significantly improve the R–L parameter constraints for all broad emission lines.

  7. Recognition of Langue des Signes Quebecoise in Eastern Canada

    ERIC Educational Resources Information Center

    Parisot, Anne-Marie; Rinfret, Julie

    2012-01-01

    This article presents a portrait of two community-level and legal efforts in Canada to obtain official recognition of ASL and LSQ (Langue des signes quebecoise), both of which are recognized as official languages by the Canadian Association of the Deaf (CAD). In order to situate this issue in the Canadian linguistic context, the authors first…

  8. Mechanistic Enzymology of the Radical SAM Enzyme DesII

    PubMed Central

    2016-01-01

    DesII is a member of the radical SAM family of enzymes that catalyzes radical-mediated transformations of TDP-4-amino-4,6-didexoy-D-glucose as well as other sugar nucleotide diphosphates. Like nearly all radical SAM enzymes, the reactions begin with the reductive homolysis of SAM to produce a 5′-deoxyadenosyl radical which is followed by regiospecific hydrogen atom abstraction from the substrate. What happens next, however, depends on the nature of the substrate radical so produced. In the case of the biosynthetically relevant substrate, a radical-mediated deamination ensues; however, when this amino group is replaced with a hydroxyl, one instead observes dehydrogenation. The factors that govern the fate of the initially generated substrate radical as well as the mechanistic details underlying these transformations have been a key focus of research into the chemistry of DesII. This review will discuss recent discoveries pertaining to the enzymology of DesII, how it may relate to understanding other radical-mediated lyases and dehydrogenases and the working hypotheses currently being investigated regarding the mechanism of DesII catalysis.

  9. L'Infection Nosocomiale en Reanimation des Brules

    PubMed Central

    Siah, S.; Belefqih, R.; Elouennass, M.; Fouadi, F.E.; Ihrai, I.

    2009-01-01

    Summary L'infection nosocomiale bactérienne étant l'une des principales causes de morbidité et de mortalité chez le brûlé, nous avons réalisé une étude rétrospective portant sur 84 patients hospitalisés au sein du service de réanimation des brûlés de l'Hôpital Militaire d'Instruction Mohammed V de Rabat, sur une période de 3 ans, du premier janvier 2001 au 31 décembre 2003. Les critères d'infection nosocomiale étaient ceux du Center for Disease Control d'Atlanta de 1988. Les taux d'incidence ont été calculés. La population infectée a été comparée à celle non infectée. L'écologie bactérienne du service a été décrite comme aussi l'antibiotype. Il ressort de cette étude la survenue de 87 infections nosocomiales chez 27 patients. L'incidence cumulative était de 103 infections pour 1000 jours de traitement. Pour ce qui est des caractéristiques des infections bactériennes, les sites infectés étaient la peau (77%), le sang (13,8%), les voies urinaires (8%) et les poumons (1,1%). Les principaux germes étaient: Staphylococcus sp. (33,3%), Pseudomonas aeruginosa (23%), Enterococcus faecalis et Acinetobacter (8%). Les staphylocoques étaient méticillo-résistants dans 22,2% des cas. Le Pseudomonas et l'Acinetobacter étaient multirésistants (60%). Dans notre étude les facteurs prédictifs de survenue des infections nosocomiales que nous avons retenus après l'étude comparative des populations infectées et non infectées ont été l'âge, le body mass index, l'abbreviated burn severity index et le remplissage initial. En isolant ces paramètres, nous avons pu établir une équation à valeur prédictive de survenue d'infection nosocomiale chez le patient brûlé. PMID:21991158

  10. Terahertz Desorption Emission Spectroscopy (THz DES) - ‘ALMA in the Lab’

    NASA Astrophysics Data System (ADS)

    Emile Auriacombe, Olivier Bruno Jacques; Fraser, Helen; Ellison, Brian; Ioppolo, Sergio; Rea, Simon

    2016-06-01

    ALMA is revolutionising our scope to identify and locate molecules that have been desorbed from ices, particularly complex organic molecules (COMS), which provide a vital link between interstellar and prebiotic chemistry. Explaining the existence of these molecules in star-forming regions relies on an empirical understanding of the chemistry that underpins their formation:- do COMS form predominantly in the solid-phase and then desorb to the gas phase, or do only “smaller” species, radials or ions desorb and then undergo gas-phase chemical reactions to generate larger COMS?-are the rotational state populations in COMS only attributable to equilibrium chemistry, or could their formation mechanisms and desorption processes affect the rotational state occupancy of these molecules, thereby directly tying certain species to solid-state origins?We have developed a novel laboratory method - THz Desorption Emission Spectroscopy (THz-DES) that combines “traditional” laboratory astrophysics high-vacuum ice experiments with a sensitive high-spectral-resolution terahertz total-power heterodyne radiometer 1,2, partially mirroring the spectral range of ALMA band 7 (275- 373 GHz). Ices are grown in situ on a cold-plate, situated in a vacuum cell, then (thermally) desorbed. The sub-mm emission spectra of the resultant gas-phase molecules are detected as a function of time, temperature, or distance from the surface. Our first THz DES results will be shown for pure and binary ice systems including H2O, N2O and CH3OH. They show good correlation with established methods e.g. TPD, with the advantage of exploiting the molecular spectroscopy to unravel surface dynamics, state-occupancy, and unequivocal molecular identification, as well as concurrently measuring desorption barriers and molecular yields. We will extend our technique to a broader frequency range, enabling us to detect radical and ion desorption, to differentiate between A and E populations of CH3OH or ortho

  11. Terahertz Desorption Emission Spectroscopy (THz DES) – ‘ALMA in the Lab’

    NASA Astrophysics Data System (ADS)

    Emile Auriacombe, Olivier Bruno Jacques; Fraser, Helen; Ellison, Brian; Ioppolo, Sergio; Rea, Simon

    2016-06-01

    ALMA is revolutionising our scope to identify and locate molecules that have been desorbed from ices, particularly complex organic molecules (COMS), which provide a vital link between interstellar and prebiotic chemistry. Explaining the existence of these molecules in star-forming regions relies on an empirical understanding of the chemistry that underpins their formation:- do COMS form predominantly in the solid-phase and then desorb to the gas phase, or do only “smaller” species, radials or ions desorb and then undergo gas-phase chemical reactions to generate larger COMS?-are the rotational state populations in COMS only attributable to equilibrium chemistry, or could their formation mechanisms and desorption processes affect the rotational state occupancy of these molecules, thereby directly tying certain species to solid-state origins?We have developed a novel laboratory method - THz Desorption Emission Spectroscopy (THz-DES) that combines “traditional” laboratory astrophysics high-vacuum ice experiments with a sensitive high-spectral-resolution terahertz total-power heterodyne radiometer 1,2, partially mirroring the spectral range of ALMA band 7 (275– 373 GHz). Ices are grown in situ on a cold-plate, situated in a vacuum cell, then (thermally) desorbed. The sub-mm emission spectra of the resultant gas-phase molecules are detected as a function of time, temperature, or distance from the surface. Our first THz DES results will be shown for pure and binary ice systems including H2O, N2O and CH3OH. They show good correlation with established methods e.g. TPD, with the advantage of exploiting the molecular spectroscopy to unravel surface dynamics, state-occupancy, and unequivocal molecular identification, as well as concurrently measuring desorption barriers and molecular yields. We will extend our technique to a broader frequency range, enabling us to detect radical and ion desorption, to differentiate between A and E populations of CH3OH or ortho

  12. Industrial ion source technology

    NASA Technical Reports Server (NTRS)

    Kaufman, H. R.; Robinson, R. S.

    1979-01-01

    In reactive ion etching of Si, varying amounts of O2 were added to the CF4 background. The experimental results indicated an etch rate less than that for Ar up to an O2 partial pressure of about .00006 Torr. Above this O2 pressure, the etch rate with CF4 exceeded that with Ar alone. For comparison the random arrival rate of O2 was approximately equal to the ion arrival rate at a partial pressure of about .00002 Torr. There were also ion source and ion pressure gauge maintenance problems as a result of the use of CF4. Large scale (4 sq cm) texturing of Si was accomplished using both Cu and stainless steel seed. The most effective seeding method for this texturing was to surround the sample with large inclined planes. Designing, fabricating, and testing a 200 sq cm rectangular beam ion source was emphasized. The design current density was 6 mA/sq cm with 500 eV argon ions, although power supply limitations permitted operation to only 2 mA/sq cm. The use of multiple rectangular beam ion sources for continuous processing of wider areas than would be possible with a single source was also studied. In all cases investigated, the most uniform coverage was obtained with 0 to 2 cm beam overlay. The maximum departure from uniform processing at optimum beam overlap was found to be +15%.

  13. Ion channels in microbes

    PubMed Central

    Martinac, Boris; Saimi, Yoshiro; Kung, Ching

    2008-01-01

    Summary Studies of ion channels have for long been dominated by the animalcentric, if not anthropocentric view of physiology. The structures and activities of ion channels had, however, evolved long before the appearance of complex multicellular organisms on Earth. The diversity of ion channels existing in cellular membranes of prokaryotes is a good example. Though at first it may appear as a paradox that most of what we know about the structure of eukaryotic ion channels is based on the structure of bacterial channels, this should not be surprising given the evolutionary relatedness of all living organisms and suitability of microbial cells for structural studies of biological macromolecules in a laboratory environment. Genome sequences of the human as well as various microbial, plant and animal organisms unambiguously established the evolutionary links, whereas crystallographic studies of the structures of major types of ion channels published over the last decade clearly demonstrated the advantage of using microbes as experimental organisms. The purpose of this review is not only to provide an account of acquired knowledge on microbial ion channels but also to show that the study of microbes and their ion channels may also hold a key to solving unresolved molecular mysteries in the future. PMID:18923187

  14. Ion photon emission microscopy

    NASA Astrophysics Data System (ADS)

    Rossi, P.; Doyle, B. L.; Banks, J. C.; Battistella, A.; Gennaro, G.; McDaniel, F. D.; Mellon, M.; Vittone, E.; Vizkelethy, G.; Wing, N. D.

    2003-09-01

    A new ion-induced emission microscopy has been invented and demonstrated, which is called ion photon emission microscopy (IPEM). It employs a low current, broad ion beam impinging on a sample, previously coated or simply covered with a few microns of a fast, highly efficient phosphor layer. The light produced at the single ion impact point is collected with an optical microscope and projected at high magnification onto a single photon position sensitive detector (PSD). This allows maps of the ion strike effects to be produced, effectively removing the need for a microbeam. Irradiation in air and even the use of alpha particle sources with no accelerator are possible. Potential applications include ion beam induced charge collection studies of semiconducting and insulating materials, single event upset studies on microchips and even biological cells in radiobiological effectiveness experiments. We describe the IPEM setup, including a 60× OM-40 microscope with a 1.5 mm hole for the beam transmission and a Quantar PSD with 60 μm pixel. Bicron plastic scintillator blades of 10 μm were chosen as a phosphor for their nanosecond time resolution, homogeneity, utility and commercial availability. The results given in this paper are for a prototype IPEM system. They indicate a resolution of ˜12 μm, the presence of a spatial halo and a He-ion efficiency of ˜20%. This marks the first time that nuclear microscopy has been performed with a radioactive source.

  15. Ion thruster performance model

    NASA Technical Reports Server (NTRS)

    Brophy, J. R.

    1984-01-01

    A model of ion thruster performance is developed for high flux density, cusped magnetic field thruster designs. This model is formulated in terms of the average energy required to produce an ion in the discharge chamber plasma and the fraction of these ions that are extracted to form the beam. The direct loss of high energy (primary) electrons from the plasma to the anode is shown to have a major effect on thruster performance. The model provides simple algebraic equations enabling one to calculate the beam ion energy cost, the average discharge chamber plasma ion energy cost, the primary electron density, the primary-to-Maxwellian electron density ratio and the Maxwellian electron temperature. Experiments indicate that the model correctly predicts the variation in plasma ion energy cost for changes in propellant gas (Ar, Kr and Xe), grid transparency to neutral atoms, beam extraction area, discharge voltage, and discharge chamber wall temperature. The model and experiments indicate that thruster performance may be described in terms of only four thruster configuration dependent parameters and two operating parameters. The model also suggests that improved performance should be exhibited by thruster designs which extract a large fraction of the ions produced in the discharge chamber, which have good primary electron and neutral atom containment and which operate at high propellant flow rates.

  16. Polarized negative ions

    SciTech Connect

    Haeberli, W.

    1981-04-01

    This paper presents a survey of methods, commonly in use or under development, to produce beams of polarized negative ions for injection into accelerators. A short summary recalls how the hyperfine interaction is used to obtain nuclear polarization in beams of atoms. Atomic-beam sources for light ions are discussed. If the best presently known techniques are incorporated in all stages of the source, polarized H/sup -/ and D/sup -/ beams in excess of 10 ..mu..A can probably be achieved. Production of polarized ions from fast (keV) beams of polarized atoms is treated separately for atoms in the H(25) excited state (Lamb-Shift source) and atoms in the H(1S) ground state. The negative ion beam from Lamb-Shift sources has reached a plateau just above 1 ..mu..A, but this beam current is adequate for many applications and the somewhat lower beam current is compensated by other desirable characteristics. Sources using fast polarized ground state atoms are in a stage of intense development. The next sections summarize production of polarized heavy ions by the atomic beam method, which is well established, and by optical pumping, which has recently been demonstrated to yield very large nuclear polarization. A short discussion of proposed ion sources for polarized /sup 3/He/sup -/ ions is followed by some concluding remarks.

  17. Lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse

    PubMed Central

    Kahan, Meldon; Wilson, Lynn; Mailis-Gagnon, Angela; Srivastava, Anita

    2011-01-01

    Résumé Objectif Présenter aux médecins de famille un résumé clinique pratique sur la prescription d’opioïdes à des populations particulières en se fondant sur les recommandations faites dans les lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse. Qualité des données Pour produire les lignes directrices, les chercheurs ont effectué une synthèse critique de la littérature médicale en insistant plus précisément sur les études de l’efficacité et de la sécurité des opioïdes dans des populations particulières. Message principal Les médecins de famille peuvent atténuer les risques de surdose, de sédation, d’usage abusif et de dépendance grâce à des stratégies adaptées à l’âge et à l’état de santé des patients. Dans le cas de patients à risque de dépendance, on devrait réserver les opioïdes aux douleurs nociceptives ou neuropathiques bien définies qui n’ont pas répondu aux traitements de première intention. Il faut procéder lentement au titrage des opioïdes, avec des dispensations fréquentes et une étroite surveillance pour dépister tout signe d’usage abusif. Une dépendance aux opioïdes suspectée est prise en charge au moyen d’une thérapie structurée aux opioïdes, d’un traitement à la méthadone ou à la buprénorphine ou encore d’un traitement fondé sur l’abstinence. Les patients souffrant de troubles de l’humeur ou d’anxiété ont tendance à avoir une réponse analgésique atténuée aux opioïdes, sont à risque plus élevé d’usage abusif et prennent souvent des sédatifs qui interagissent défavorablement avec les opioïdes. Il faut prendre des précautions semblables à celles utilisées avec d’autres patients à risque élevé. Il faut faire un sevrage progressif si la douleur du patient demeure sévère même avec un essai adéquat de thérapie aux opioïdes. Chez les personnes âgées, la s

  18. Les reseaux de politique publique comme facteur d'influence du choix des instruments de politique energetique canadienne a des fins environnementales de 1993 a nos jours

    NASA Astrophysics Data System (ADS)

    Fathy El Dessouky, Naglaa

    Au cours de la derniere decennie, les modes de la gouvernance ont pris place dans un contexte totalement different de celui qu'ils avaient auparavant. Les gouvernements modernes se rendent compte qu'ils perdent de plus en plus leur capacite a elaborer et a gerer les changements d'une maniere autonome. Ainsi, les fonctions et les activites traditionnellement accomplies exclusivement par le gouvernement engagent de nos jours une gamme d'acteurs etatiques et non etatiques. A l'encontre du concept traditionnel de l'Etat controleur, la gouvernance contemporaine est ainsi devenue moins une question d'offre de service et davantage une gestion indirecte des reseaux de politique publique. Dans cette entreprise, les gouvernements contemporains, cherchant plus d'information, de soutien et de legitimite en matiere de formulation des decisions, ont besoin d'etablir des relations avec les divers groupes d'interet qui, a leur tour, voulaient plus de promotion et de protection en faveur de leurs interets a travers leur implication au processus de l'elaboration et de la mise en oeuvre des politiques publiques. Ainsi, l'approche des reseaux de politique publique represente aujourd'hui un courant considerable au sein du champ d'analyse des politiques publiques. Toutefois, les preoccupations des chercheurs pour cette approche, dans le domaine des politiques energetiques a des fins environnementales, semblent recentes, et les etudes realisees sont encore trop peu nombreuses. Au Canada, au debut des annees 1990, le gouvernement ainsi que plusieurs groupes d'interets, des differents secteurs energetique, industriel et environnemental, ont commence a intensifier leurs efforts pour s'attaquer au probleme du changement climatique d'origine energetique, genere surtout par le secteur de l'industrie. Au cours de la derniere decennie, la question touchant plutot le sujet du developpement energetique durable represente le plus important domaine des politiques publiques ayant surgi recemment dans

  19. La biogenèse des mélanosomes

    PubMed Central

    Delevoye, Cédric; Giordano, Francesca; van Niel, Guillaume; Raposo, Graça

    2012-01-01

    Les mélanocytes situés à la base de l’épiderme produisent des mélanosomes qui sont transférés aux kératinocytes pour assurer la pigmentation de l’épiderme et sa photoprotection contre les rayons ultraviolets. Les mélanosomes, organites apparentés aux lysosomes, sont le lieu de synthèse et de stockage d’un pigment, la mélanine. Leur formation dépend de protéines mélanosomales qui transitent par les voies de biosynthèse et d’endocytose et exploitent les mécanismes moléculaires du trafic intracellulaire. Les acteurs moléculaires impliqués dans le transport des protéines mélanosomales et la biogenèse des mélanosomes sont la cible de mutations dans des maladies génétiques accompagnées d’hypopigmentation comme l’albinisme et les maladies lysosomales. Les études menées sur les mélanocytes issus de souris modèles de ces maladies permettent de comprendre certaines des étapes-clés de la mélanogenèse ainsi que les dysfonctionnements associés à ces pathologies. De plus, décrypter la mélanogenèse facilite également la compréhension d’autres processus physiologiques, comme l’illustrent les similitudes inattendues avec l’amyloïdogenèse dans les maladies neurodégénératives. PMID:21382323

  20. Laser-cooled atomic ions as probes of molecular ions

    SciTech Connect

    Brown, Kenneth R.; Viteri, C. Ricardo; Clark, Craig R.; Goeders, James E.; Khanyile, Ncamiso B.; Vittorini, Grahame D.

    2015-01-22

    Trapped laser-cooled atomic ions are a new tool for understanding cold molecular ions. The atomic ions not only sympathetically cool the molecular ions to millikelvin temperatures, but the bright atomic ion fluorescence can also serve as a detector of both molecular reactions and molecular spectra. We are working towards the detection of single molecular ion spectra by sympathetic heating spectroscopy. Sympathetic heating spectroscopy uses the coupled motion of two trapped ions to measure the spectra of one ion by observing changes in the fluorescence of the other ion. Sympathetic heating spectroscopy is a generalization of quantum logic spectroscopy, but does not require ions in the motional ground state or coherent control of the ion internal states. We have recently demonstrated this technique using two isotopes of Ca{sup +} [Phys. Rev. A, 81, 043428 (2010)]. Limits of the method and potential applications for molecular spectroscopy are discussed.

  1. Ion dynamics during seizures

    PubMed Central

    Raimondo, Joseph V.; Burman, Richard J.; Katz, Arieh A.; Akerman, Colin J.

    2015-01-01

    Changes in membrane voltage brought about by ion fluxes through voltage and transmitter-gated channels represent the basis of neural activity. As such, electrochemical gradients across the membrane determine the direction and driving force for the flow of ions and are therefore crucial in setting the properties of synaptic transmission and signal propagation. Ion concentration gradients are established by a variety of mechanisms, including specialized transporter proteins. However, transmembrane gradients can be affected by ionic fluxes through channels during periods of elevated neural activity, which in turn are predicted to influence the properties of on-going synaptic transmission. Such activity-induced changes to ion concentration gradients are a feature of both physiological and pathological neural processes. An epileptic seizure is an example of severely perturbed neural activity, which is accompanied by pronounced changes in intracellular and extracellular ion concentrations. Appreciating the factors that contribute to these ion dynamics is critical if we are to understand how a seizure event evolves and is sustained and terminated by neural tissue. Indeed, this issue is of significant clinical importance as status epilepticus—a type of seizure that does not stop of its own accord—is a life-threatening medical emergency. In this review we explore how the transmembrane concentration gradient of the six major ions (K+, Na+, Cl−, Ca2+, H+and HCO3−) is altered during an epileptic seizure. We will first examine each ion individually, before describing how multiple interacting mechanisms between ions might contribute to concentration changes and whether these act to prolong or terminate epileptic activity. In doing so, we will consider how the availability of experimental techniques has both advanced and restricted our ability to study these phenomena. PMID:26539081

  2. Relation entre les caractéristiques des table-bancs et les mesures anthropométriques des écoliers au Benin

    PubMed Central

    Falola, Stève Marjelin; Gouthon, Polycarpe; Falola, Jean-Marie; Fiogbe, Michel Armand; Nigan, Issiako Bio

    2014-01-01

    Introduction Le mobilier scolaire et la posture assise en classe sont souvent impliqués dans l'apparition des douleurs rachidiennes, influant de fait sur la qualité des tâches réalisées par les apprenants. Aucune étude n'a encore vérifié le degré d'adéquation entre les caractéristiques du mobilier et celles des écoliers au Bénin. L'objectif de cette étude transversale est donc de déterminer la relation entre les dimensions des table-bancs utilisées en classe et les mesures anthropométriques des écoliers au Bénin. Methods Elle a été réalisée avec un échantillon probabiliste de 678 écoliers, âgés de 4 à 17 ans. Les mesures anthropométriques des écoliers et les mensurations relatives aux longueurs, largeurs et hauteurs des table-bancs ont été mesurées, puis intégrées aux équations proposées dans la littérature. Les pourcentages des valeurs situées hors des limitesacceptables, dérivées de l'application des équations ont été calculés. Results La largeur et la hauteur des table-bancs utilisées par les écoliers étaient plus élevées (p < 0,05) que les valeurs de référence recommandées par les structures officielles de contrôle et de production des mobiliers scolaires au Bénin. Quel que soit le sexe, il y avait une inadéquation entre la largeur du banc et la longueur fesse-poplité, puis entre la hauteur de la table et la distance coude-bancdes écoliers. Conclusion Les résultats suggèrent de prendre en compte l’évolution des mesures anthropométriques des écoliers dans la confection des table-bancs, afin de promouvoir de bonnes postures assises en classe et de réduire le risque de troubles du rachis. PMID:25317232

  3. Optimisation des proprietes fonctionnelles des alliages a memoire de forme suite a l'application de traitements thermomecaniques

    NASA Astrophysics Data System (ADS)

    Demers, Vincent

    L'objectif de ce projet est de determiner les conditions de laminage et la temperature de traitement thermique maximisant les proprietes fonctionnelles de l'alliage a memoire de forme Ti-Ni. Les specimens sont caracterises par des mesures de calorimetrie, de microscopie optique, de gene ration de contrainte, de deformation recuperable et des essais mecaniques. Pour un cycle unique, l'utilisation d'un taux d'ecrouissage e=1.5 obtenu avec l'application d'une force de tension FT = 0.1sigma y et d'une huile minerale resulte en un echantillon droit, sans microfissure et qui apres un recuit a 400°C, produit un materiau nanostructure manifestant des proprietes fonctionnelles deux fois plus grandes que le meme materiau ayant une structure polygonisee. Pour des cycles repetes, les memes conditions de laminage sont valables mais le niveau de deformation optimal est situe entre e=0.75-2, et depend particulierement du mode de sollicitation, du niveau de stabilisation et du nombre de cycles a la rupture requis par l'application.

  4. Heavy-ion dosimetry

    SciTech Connect

    Schimmerling, W.

    1980-03-01

    This lecture deals with some of the more important physical characteristics of relativistic heavy ions and their measurement, with beam delivery and beam monitoring, and with conventional radiation dosimetry as used in the operation of the BEVALAC biomedical facility for high energy heavy ions (Lyman and Howard, 1977; BEVALAC, 1977). Even so, many fundamental aspects of the interaction of relativistic heavy ions with matter, including important atomic physics and radiation chemical considerations, are not discussed beyond the reminder that such additional understanding is required before an adequte perspective of the problem can be attained.

  5. ION PRODUCING MECHANISM

    DOEpatents

    Lawrence, E.O.

    1958-09-16

    Improvements are presented in calutron devices and, more specifically, dealswith an improved mounting arrangement fer the ion source of the calutron. An important feature of the invention resides in a pluraiity of insulators so mounted as to be accessible from the exterior of the calutron tank and supporting at their inner ends the ion source. These insutators are arranged in mutually parallel relation and also parallel to the flux of the nmgnetic field, whereby the strain of the supporting elements is reduced to a minimum. In addition the support assembly is secured to a removable wall portion of the task to facilitate withdrawal and examination of the ion producing mechanism.

  6. Relating to ion detection

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2001-01-01

    The apparatus and method provide a technique for improving detection of alpha and/or beta emitting sources on items or in locations using indirect means. The emission forms generate ions in a medium surrounding the item or location and the medium is then moved to a detecting location where the ions are discharged to give a measure of the emission levels. To increase the level of ions generated and render the system particularly applicable for narrow pipes and other forms of conduits, the medium pressure is increased above atmospheric pressure. STATEMENT REGARDING FEDERALLY SPONSORED RESEARCH OR DEVELOPMENT

  7. ION ROCKET ENGINE

    DOEpatents

    Ehlers, K.W.; Voelker, F. III

    1961-12-19

    A thrust generating engine utilizing cesium vapor as the propellant fuel is designed. The cesium is vaporized by heat and is passed through a heated porous tungsten electrode whereby each cesium atom is fonized. Upon emergfng from the tungsten electrode, the ions are accelerated rearwardly from the rocket through an electric field between the tungsten electrode and an adjacent accelerating electrode grid structure. To avoid creating a large negative charge on the space craft as a result of the expulsion of the positive ions, a source of electrons is disposed adjacent the ion stream to neutralize the cesium atoms following acceleration thereof. (AEC)

  8. Phosphoinositides regulate ion channels

    PubMed Central

    Hille, Bertil; Dickson, Eamonn J.; Kruse, Martin; Vivas, Oscar; Suh, Byung-Chang

    2014-01-01

    Phosphoinositides serve as signature motifs for different cellular membranes and often are required for the function of membrane proteins. Here, we summarize clear evidence supporting the concept that many ion channels are regulated by membrane phosphoinositides. We describe tools used to test their dependence on phosphoinositides, especially phosphatidylinositol 4,5-bisphosphate, and consider mechanisms and biological meanings of phosphoinositide regulation of ion channels. This lipid regulation can underlie changes of channel activity and electrical excitability in response to receptors. Since different intracellular membranes have different lipid compositions, the activity of ion channels still in transit towards their final destination membrane may be suppressed until they reach an optimal lipid environment. PMID:25241941

  9. Ion wave breaking acceleration

    NASA Astrophysics Data System (ADS)

    Liu, B.; Meyer-ter-Vehn, J.; Bamberg, K.-U.; Ma, W. J.; Liu, J.; He, X. T.; Yan, X. Q.; Ruhl, H.

    2016-07-01

    Laser driven ion wave breaking acceleration (IWBA) in plasma wakefields is investigated by means of a one-dimensional (1D) model and 1D/3D particle-in-cell (PIC) simulations. IWBA operates in relativistic transparent plasma for laser intensities in the range of 1020- 1023 W /cm2 . The threshold for IWBA is identified in the plane of plasma density and laser amplitude. In the region just beyond the threshold, self-injection takes place only for a fraction of ions and in a limited time period. This leads to well collimated ion pulses with peaked energy spectra, in particular for 3D geometry.

  10. Ion beam accelerator system

    NASA Technical Reports Server (NTRS)

    Aston, Graeme (Inventor)

    1984-01-01

    A system is described that combines geometrical and electrostatic focusing to provide high ion extraction efficiency and good focusing of an accelerated ion beam. The apparatus includes a pair of curved extraction grids (16, 18) with multiple pairs of aligned holes positioned to direct a group of beamlets (20) along converging paths. The extraction grids are closely spaced and maintained at a moderate potential to efficiently extract beamlets of ions and allow them to combine into a single beam (14). An accelerator electrode device (22) downstream from the extraction grids, is at a much lower potential than the grids to accelerate the combined beam.

  11. Ion acoustic solitons in a plasma with finite temperature drifting ions: Limit on ion drift velocity

    SciTech Connect

    Malik, H.K.; Singh, S.; Dahiya, R.P. )

    1994-05-01

    Propagation of ion acoustic solitons in a plasma consisting of finite temperature drifting ions and nondrifting electrons has been studied. It is shown that in addition to the electron inertia and weak relativistic effects, the ion temperature also modifies the soliton behavior. By including the finite ion temperature, limit for the ion drift velocity [ital u][sub 0] for which the ion acoustic solitons are possible, is obtained. The solitons can exist for [ital v][sub [ital Te

  12. Microscopie interférentielle X-UV : un outil pour l'étude des endommagements des surfaces optiques

    NASA Astrophysics Data System (ADS)

    Jamelot, G.; Ros, D.; Cassou, K.; Kazamias, S.; Klisnick, A.; Kozlová, M.; Mocek, T.; Homer, P.; Polan, J.; Stupka, M.

    2006-12-01

    Nous présentons des résultats récents concernant des premières investigations de microscopie interférentielle par laser X-UV d'endommagement optique. Le laser X-UV utilisé est un laser collisionnel en régime quasi-stationnaire émettant à 21.2 nm, développé au Prague Asterix Laser System (PALS, Prague, République Tchèque). Des échantillons de silice fondue de haute qualité, avec ou sans rayure, étaient irradiées en face avant par un laser bleu, correspondant au 3selectfontfontsize{7{9}{textrm{ème}}} harmonique du laser à iode du PALS (1.315 μ m), servant également à réaliser le laser X-UV à 21.2 nm. Celui-ci était utilisé, 5 ns après l'irradiation pour réaliser une imagerie microscopique et interférentielle de la face arrière de l'échantillon. Les résultats font apparaître des déformations locales transitoires. Des premières analyses mettent en évidence une probable variation de la rugosité de la surface. Cette démonstration expérimentale encourageante ouvre la voie à de futures investigations, notamment sur notre prochaine installation laser : LASERIX.

  13. Methodes iteratives paralleles: Applications en neutronique et en mecanique des fluides

    NASA Astrophysics Data System (ADS)

    Qaddouri, Abdessamad

    Dans cette these, le calcul parallele est applique successivement a la neutronique et a la mecanique des fluides. Dans chacune de ces deux applications, des methodes iteratives sont utilisees pour resoudre le systeme d'equations algebriques resultant de la discretisation des equations du probleme physique. Dans le probleme de neutronique, le calcul des matrices des probabilites de collision (PC) ainsi qu'un schema iteratif multigroupe utilisant une methode inverse de puissance sont parallelises. Dans le probleme de mecanique des fluides, un code d'elements finis utilisant un algorithme iteratif du type GMRES preconditionne est parallelise. Cette these est presentee sous forme de six articles suivis d'une conclusion. Les cinq premiers articles traitent des applications en neutronique, articles qui representent l'evolution de notre travail dans ce domaine. Cette evolution passe par un calcul parallele des matrices des PC et un algorithme multigroupe parallele teste sur un probleme unidimensionnel (article 1), puis par deux algorithmes paralleles l'un mutiregion l'autre multigroupe, testes sur des problemes bidimensionnels (articles 2--3). Ces deux premieres etapes sont suivies par l'application de deux techniques d'acceleration, le rebalancement neutronique et la minimisation du residu aux deux algorithmes paralleles (article 4). Finalement, on a mis en oeuvre l'algorithme multigroupe et le calcul parallele des matrices des PC sur un code de production DRAGON ou les tests sont plus realistes et peuvent etre tridimensionnels (article 5). Le sixieme article (article 6), consacre a l'application a la mecanique des fluides, traite la parallelisation d'un code d'elements finis FES ou le partitionneur de graphe METIS et la librairie PSPARSLIB sont utilises.

  14. Ion manipulation device

    DOEpatents

    Anderson, Gordon A; Smith, Richard D; Ibrahim, Yehia M; Baker, Erin M

    2014-09-16

    An ion manipulation method and device is disclosed. The device includes a pair of substantially parallel surfaces. An array of inner electrodes is contained within, and extends substantially along the length of, each parallel surface. The device includes a first outer array of electrodes and a second outer array of electrodes. Each outer array of electrodes is positioned on either side of the inner electrodes, and is contained within and extends substantially along the length of each parallel surface. A DC voltage is applied to the first and second outer array of electrodes. A RF voltage, with a superimposed electric field, is applied to the inner electrodes by applying the DC voltages to each electrode. Ions either move between the parallel surfaces within an ion confinement area or along paths in the direction of the electric field, or can be trapped in the ion confinement area.

  15. Ion sensing method

    DOEpatents

    Smith, Richard Harding; Martin, Glenn Brian

    2004-05-18

    The present invention allows the determination of trace levels of ionic substances in a sample solution (ions, metal ions, and other electrically charged molecules) by coupling a separation method, such as liquid chromatography, with ion selective electrodes (ISE) prepared so as to allow detection at activities below 10.sup.-6 M. The separation method distributes constituent molecules into fractions due to unique chemical and physical properties, such as charge, hydrophobicity, specific binding interactions, or movement in an electrical field. The separated fractions are detected by means of the ISE(s). These ISEs can be used singly or in an array. Accordingly, modifications in the ISEs are used to permit detection of low activities, specifically, below 10.sup.-6 M, by using low activities of the primary analyte (the molecular species which is specifically detected) in the inner filling solution of the ISE. Arrays constructed in various ways allow flow-through sensing for multiple ions.

  16. Focused ion beam system

    DOEpatents

    Leung, Ka-Ngo; Gough, Richard A.; Ji, Qing; Lee, Yung-Hee Yvette

    1999-01-01

    A focused ion beam (FIB) system produces a final beam spot size down to 0.1 .mu.m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 .mu.m or less.

  17. Ion Milling of Sapphire

    NASA Technical Reports Server (NTRS)

    Gregory, Don A.; Herren, Kenneth A.

    2004-01-01

    The ion milling of sapphire is a complicated operation due to several characteristics of the material itself. It is a relatively hard transparent nonconductive crystalline material that does not transfer heat nearly as well as metals that have been successfully ion milled in the past. This investigation involved designing an experimental arrangement, using existing ion milling equipment, as the precursor to figuring the surface of sapphire and other insulating optical materials. The experimental arrangement employs a laser probe beam to constantly monitor the stresses being induced in the material, as it is being ion milled. The goal is to determine if the technique proposed would indeed indicate the stress being induced in the material so that these stresses can be managed to prevent failure of the optic.

  18. Focused ion beam system

    DOEpatents

    Leung, K.; Gough, R.A.; Ji, Q.; Lee, Y.Y.

    1999-08-31

    A focused ion beam (FIB) system produces a final beam spot size down to 0.1 {mu}m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 m or less. 13 figs.

  19. Planar ion microtraps

    NASA Astrophysics Data System (ADS)

    Brewer, R. G.; Devoe, R. G.; Kallenbach, R.

    1992-12-01

    Planar quadrupole ion traps have been analyzed through numerical and analytic solutions of Laplace's equation. These involve either one or more conducting rings or their analogs, a hole in one or more conducting sheets. The leading terms in the potential are harmonic, corresponding to the Paul trap, but with coefficients that reduce their efficiency and for some traps, the anharmonic terms can be suppressed to eighth-order. Stable ion trapping is predicted for all electrode configurations possessing radial and axial symmetry. A three-hole microtrap with an inner hole radius of 80 μm trapped from one to many (dense clouds) laser-cooled Ba+ ions where the two-ion distance is compressed to 1 μm, allowing new experiments in quantum optics. Also, arrays of traps for optical clocks are contemplated using photolithographic fabrication.

  20. Trapping radioactive ions

    NASA Astrophysics Data System (ADS)

    Kluge, H.-J.; Blaum, K.

    2004-12-01

    Trapping devices for atomic and nuclear physics experiments with radioactive ions are becoming more and more important at accelerator facilities. While about ten years ago only one online Penning trap experiment existed, namely ISOLTRAP at ISOLDE/CERN, meanwhile almost every radioactive beam facility has installed or plans an ion trap setup. This article gives an overview on ion traps in the operation, construction or planing phase which will be used for fundamental studies with short-lived radioactive nuclides such as mass spectrometry, laser spectroscopy and nuclear decay spectroscopy. In addition, this article summarizes the use of gas cells and radiofrequency quadrupole (Paul) traps at different facilities as a versatile tool for ion beam manipulation like retardation, cooling, bunching, and cleaning.

  1. Ion beam texturing

    NASA Technical Reports Server (NTRS)

    Hudson, W. R.

    1976-01-01

    A microscopic surface texture is created by sputter etching a surface while simultaneously sputter depositing a lower sputter yield material onto the surface. A xenon ion beam source has been used to perform this texturing process on samples as large as three centimeters in diameter. Ion beam textured surface structures have been characterized with SEM photomicrographs for a large number of materials including Cu, Al, Si, Ti, Ni, Fe, Stainless steel, Au, and Ag. Surfaces have been textured using a variety of low sputter yield materials - Ta, Mo, Nb, and Ti. The initial stages of the texture creation have been documented, and the technique of ion beam sputter removal of any remaining deposited material has been studied. A number of other texturing parameters have been studied such as the variation of the texture with ion beam power, surface temperature, and the rate of texture growth with sputter etching time.

  2. COASTING ARC ION SOURCE

    DOEpatents

    Foster, J.S. Jr.

    1957-09-10

    An improved ion source is described and in particular a source in which the ions are efficiently removed. The plasma is generated in a tubular amode structure by the oscillation of electrons in an axial magnetic field, as in the Phillips Ion Gage. The novel aspect of the source is the expansion of the plasma as it leaves the anode structure, so as to reduce the ion density at the axis of the anode and present a uniform area of plasma to an extraction grid. The structure utilized in the present patent to expand the plasma comprises flange members of high permeability at the exitgrid end of the amode to diverge the magnetic field adjacent the exit.

  3. Pulsed ion beam source

    DOEpatents

    Greenly, John B.

    1997-01-01

    An improved pulsed ion beam source having a new biasing circuit for the fast magnetic field. This circuit provides for an initial negative bias for the field created by the fast coils in the ion beam source which pre-ionize the gas in the source, ionize the gas and deliver the gas to the proper position in the accelerating gap between the anode and cathode assemblies in the ion beam source. The initial negative bias improves the interaction between the location of the nulls in the composite magnetic field in the ion beam source and the position of the gas for pre-ionization and ionization into the plasma as well as final positioning of the plasma in the accelerating gap. Improvements to the construction of the flux excluders in the anode assembly are also accomplished by fabricating them as layered structures with a high melting point, low conductivity material on the outsides with a high conductivity material in the center.

  4. Ion exchange phenomena

    SciTech Connect

    Bourg, I.C.; Sposito, G.

    2011-05-01

    Ion exchange phenomena involve the population of readily exchangeable ions, the subset of adsorbed solutes that balance the intrinsic surface charge and can be readily replaced by major background electrolyte ions (Sposito, 2008). These phenomena have occupied a central place in soil chemistry research since Way (1850) first showed that potassium uptake by soils resulted in the release of an equal quantity of moles of charge of calcium and magnesium. Ion exchange phenomena are now routinely modeled in studies of soil formation (White et al., 2005), soil reclamation (Kopittke et al., 2006), soil fertilitization (Agbenin and Yakubu, 2006), colloidal dispersion/flocculation (Charlet and Tournassat, 2005), the mechanics of argillaceous media (Gajo and Loret, 2007), aquitard pore water chemistry (Tournassat et al., 2008), and groundwater (Timms and Hendry, 2007; McNab et al., 2009) and contaminant hydrology (Chatterjee et al., 2008; van Oploo et al., 2008; Serrano et al., 2009).

  5. Mesure des stades de developpement du sapin baumier (Abies balsamea [L.] Mill.) par teledetection des maxima locaux sur images a tres haute resolution

    NASA Astrophysics Data System (ADS)

    Demers, Alain

    L'objectif principal de cette these est d'identifier les parametres cles pour lier le developpement morphologique de la cime du sapin baumier (Abies balsamea [L.] Mill.) aux patrons de reflectance qu'elle genere sur une image aerienne a haute resolution. La quantite et la distribution spatiale des aiguilles dans le sapin dependent de la structure des branches. Un mecanisme de ramification particulier (la reiteration) ressort comme le parametre cle pour lier l'augmentation de la biomasse foliaire et la forme de la branche. Les reiterats forment des agglomerats de feuillage qui engendrent des inegalites dans les patrons de reflectance de la cime. La reflectance est plus elevee ou il y a une forte concentration de reiterats (maximum local). On demontre que le developpement du sapin baumier se mesure au moyen de l'analyse des maxima locaux de la cime sur une image. La biomasse de l'arbre se mesure par la teledetection et l'analyse des patrons de reflectance de la cime, c'est-a-dire la mesure du niveau de reiteration par le decompte des maxima locaux de la cime. Cette etude demontre qu'il est possible de proceder a l'inventaire du volume de bois d'un peuplement par la teledetection de l'architecture des arbres.

  6. Ion replacement electrorefining

    SciTech Connect

    Willit, J.L.; Tomczuk, Z.; Miller, W.E.; Laidler, J.J.

    1994-04-01

    We are developing a two-step electrochemical process for purifying and separating metals called ion replacement electrorefining. In each step, metal cations formed by oxidation at an electrode replace other metal cations that are reduced at another elecmae. Using this approach, we have separated or purified uranium, dysprosium, and lanthanum on a laboratory scale. This paper explains the ion replacement concept and presents results of these demonstration experiments.

  7. Miniaturized Ion Mobility Spectrometer

    NASA Technical Reports Server (NTRS)

    Kaye, William J. (Inventor); Stimac, Robert M. (Inventor)

    2015-01-01

    By utilizing the combination of a unique electronic ion injection control circuit in conjunction with a particularly designed drift cell construction, the instantly disclosed ion mobility spectrometer achieves increased levels of sensitivity, while achieving significant reductions in size and weight. The instant IMS is of a much simpler and easy to manufacture design, rugged and hermetically sealed, capable of operation at high temperatures to at least 250.degree. C., and is uniquely sensitive, particularly to explosive chemicals.

  8. Ion electric propulsion unit

    DOEpatents

    Light, Max E; Colestock, Patrick L

    2014-01-28

    An electron cyclotron resonance (ECR) thruster is disclosed having a plasma chamber which is electrically biased with a positive voltage. The chamber bias serves to efficiently accelerate and expel the positive ions from the chamber. Electrons follow the exiting ions, serving to provide an electrically neutral exhaust plume. In a further embodiment, a downstream shaping magnetic field serves to further accelerate and/or shape the exhaust plume.

  9. HIGH VOLTAGE ION SOURCE

    DOEpatents

    Luce, J.S.

    1960-04-19

    A device is described for providing a source of molecular ions having a large output current and with an accelerated energy of the order of 600 kv. Ions are produced in an ion source which is provided with a water-cooled source grid of metal to effect maximum recombination of atomic ions to molecular ions. A very high accelerating voltage is applied to withdraw and accelerate the molecular ions from the source, and means are provided for dumping the excess electrons at the lowest possible potentials. An accelerating grid is placed adjacent to the source grid and a slotted, grounded accelerating electrode is placed adjacent to the accelerating grid. A potential of about 35 kv is maintained between the source grid and accelerating grid, and a potential of about 600 kv is maintained between the accelerating grid and accelerating electrode. In order to keep at a minimum the large number of oscillating electrons which are created when such high voltages are employed in the vicinity of a strong magnetic field, a plurality of high voltage cascaded shields are employed with a conventional electron dumping system being employed between each shield so as to dump the electrons at the lowest possible potential rather than at 600 kv.

  10. Advanced ion thruster research

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1985-01-01

    A series of experiments conducted on a ring cusp magnetic field ion thruster; in which the anode, cathode and discharge chamber backplate were moved relative to the magnetic cusp; are described. Optimum locations for the anode, cathode and backplate which yield the lowest energy cost per plasma ion and highest extracted ion fraction are identified. The results are discussed in terms of simple physical models. The results of preliminary experiments into the operation of hollow cathodes on nitrogen and xenon over a large pressure range (0.1 to 100 Torr) are presented. They show that the cathode discharge transfers from the cathode insert to the exterior edge of the orifice plate as the interelectrode pressure is increased. Experimental evidence showing that a new ion extractor grid concept can be used to stabilize the plasma sheath at the screen grid is presented. This concept, identified by the term constrained sheath optics, is shown to hold ion beamlet divergence and impingement characteristics to stable values as the beamlet current and the net and total accelerating voltages are changed. The current status of a study of beamlet vectoring induced by displacing the accelerator and/or decelerator grids of a three grid ion extraction system relative to the screen grid is discussed.

  11. Microscale continuous ion exchanger.

    PubMed

    Kuban, Petr; Dasgupta, Purnendu K; Morris, Kavin A

    2002-11-01

    A microscale continuous ion exchanger based on two liquid streams flowing in parallel is presented. The ion exchange reaction occurs through diffusional transfer of molecules between the ion exchanger phase and the eluent phase and is applied for conductivity suppression. Two approaches are demonstrated. In the first approach, a liquid ion exchanger (i.e. a strongly basic compound, e.g., tetraoctylammonium hydroxide, or a secondary amine, e.g., Amberlite IA-2) is dissolved in an organic solvent immiscible with the aqueous eluent. The system allows for sensitive suppressed conductivity detection of various inorganic cations. When the weakly basic secondary amine is used, conductometric detection of heavy metals is possible. In the second approach, a suspension of finely ground ion-exchange resin is used as the ion exchanger phase. In this case, the suspension need not involve an organic solvent. Theoretical models and computations are presented along with experimental results. The potential of such a system as a chip-scale post-separation suppressor/reactor is evident.

  12. Ion channels and cancer.

    PubMed

    Kunzelmann, Karl

    2005-06-01

    Membrane ion channels are essential for cell proliferation and appear to have a role in the development of cancer. This has initially been demonstrated for potassium channels and is meanwhile also suggested for other cation channels and Cl- channels. For some of these channels, like voltage-gated ether à go-go and Ca2+-dependent potassium channels as well as calcium and chloride channels, a cell cycle-dependent function has been demonstrated. Along with other membrane conductances, these channels control the membrane voltage and Ca2+ signaling in proliferating cells. Homeostatic parameters, such as the intracellular ion concentration, cytosolic pH and cell volume, are also governed by the activity of ion channels. Thus it will be an essential task for future studies to unravel cell cycle-specific effects of ion channels and non-specific homeostatic functions. When studying the role of ion channels in cancer cells, it is indispensable to choose experimental conditions that come close to the in vivo situation. Thus, environmental parameters, such as low oxygen pressure, acidosis and exposure to serum proteins, have to be taken into account. In order to achieve clinical application, more studies on the original cancer tissue are required, and improved animal models. Finally, it will be essential to generate more potent and specific inhibitors of ion channels to overcome the shortcomings of some of the current approaches.

  13. Single ion heat engine

    NASA Astrophysics Data System (ADS)

    Singer, Kilian

    2015-03-01

    An experimental realization of a heat engine with a single ion is presented, which will allow for work extraction even with non-classical thermal reservoirs. To this goal a custom designed linear Paul trap with a single ion performing an Otto cycle is presented. The radial state of the ion is used as the working gas analogous to the gas in a conventional heat engine. The conventional piston is realized by the axial degrees of freedom and the axial motional excitation stores the generated work, just like a conventional fly-wheel. The heat baths can be realized by tailored laser radiation. Alternatively electrical noise can be used to control the state of the ion. The presented system possesses advantageous properties, as the working parameters can be tuned over a broad range and the motional degrees of freedom of the ion can be accurately determined. Dark resonances allow for fast stroboscopic thermometry during the entire working cycle. Monte Carlo simulations are performed to predict the efficiency and the gained work of the working cycle. We have also shown how the equations for the Carnot limit have to be modified if a squeezed thermal reservoir is employed. Furthermore structural phase transitions with laser cooled linear ion crystals are induced verifying the Kibble-Zurek mechanism.

  14. Secondary ion collection and transport system for ion microprobe

    DOEpatents

    Ward, James W.; Schlanger, Herbert; McNulty, Jr., Hugh; Parker, Norman W.

    1985-01-01

    A secondary ion collection and transport system, for use with an ion microprobe, which is very compact and occupies only a small working distance, thereby enabling the primary ion beam to have a short focal length and high resolution. Ions sputtered from the target surface by the primary beam's impact are collected between two arcuate members having radii of curvature and applied voltages that cause only ions within a specified energy band to be collected. The collected ions are accelerated and focused in a transport section consisting of a plurality of spaced conductive members which are coaxial with and distributed along the desired ion path. Relatively high voltages are applied to alternate transport sections to produce accelerating electric fields sufficient to transport the ions through the section to an ion mass analyzer, while lower voltages are applied to the other transport sections to focus the ions and bring their velocity to a level compatible with the analyzing apparatus.

  15. Ion-ion waves in the auroral region - Wave excitation and ion heating

    NASA Technical Reports Server (NTRS)

    Dusenbery, P. B.; Martin, R. F., Jr.; Winglee, R. M.

    1988-01-01

    The properties of the ion-ion mode which is excited in plasmas when two or more cold ion beams are streaming relative to one another are investigated assuming a warm electron distribution at rest (the model consistent with particle distributions observed in auroral plasma cavities). Numerical solutions are derived for the generalized electrostatic dispersion equation for parallel propagation and for oblique propagation of ion waves. It is shown that the relative ion temperature and concentration have significant effects on the stability of the accelerated plasma and the expected ion heating. Finally, a relationship between ion drift and thermal speed is derived using the marginal stability of ion-ion waves for nonzero ion temperature; the relationship was found to compare favorably with DE-1 ion observations at the high-altitude boundary of the auroral cavity.

  16. Radiative ion-ion neutralization: a new gas-phase atmospheric pressure ion transduction mechanism.

    PubMed

    Davis, Eric J; Siems, William F; Hill, Herbert H

    2012-06-01

    All atmospheric pressure ion detectors, including photo ionization detectors, flame ionization detectors, electron capture detectors, and ion mobility spectrometers, utilize Faraday plate designs in which ionic charge is collected and amplified. The sensitivity of these Faraday plate ion detectors are limited by thermal (Johnson) noise in the associated electronics. Thus approximately 10(6) ions per second are required for a minimal detection. This is not the case for ion detection under vacuum conditions where secondary electron multipliers (SEMs) can be used. SEMs produce a cascade of approximately 10(6) electrons per ion impinging on the conversion dynode. Similarly, photomultiplier tubes (PMTs) can generate approximately 10(6) electrons per photon. Unlike SEMs, however, PMTs are evacuated and sealed so that they are commonly used under atmospheric pressure conditions. This paper describes an atmospheric pressure ion detector based on coupling a PMT with light emitted from ion-ion neutralization reactions. The normal Faraday plate collector electrode was replaced with an electrode "needle" used to concentrate the anions as they were drawn to the tip of the needle by a strong focusing electric field. Light was emitted near the surface of the electrode when analyte ions were neutralized with cations produced from the anode. Although radiative-ion-ion recombination has been previously reported, this is the first time ions from separate ionization sources have been combined to produce light. The light from this radiative-ion-ion-neutralization (RIIN) was detected using a photon multiplier such that an ion mobility spectrum was obtained by monitoring the light emitted from mobility separated ions. An IMS spectrum of nitroglycerin (NG) was obtained utilizing RIIN for tranducing the mobility separated ions into an analytical signal. The implications of this novel ion transduction method are the potential for counting ions at atmospheric pressure and for obtaining ion

  17. Heavy ion tumour therapy

    NASA Astrophysics Data System (ADS)

    Scholz, M.

    2000-03-01

    Ion beams represent a promising radiotherapy modality for the treatment of deep seated tumours. Compared to conventional photon beams, in particular beams of heavier ions like e.g. carbon show several advantages which are related to their different physical and radiobiological properties: The dose increases with penetration depth and shows a sharp distal fall off at the end of the particle range, i.e., the depth dose profile is inverted compared to photon beams. They exhibit an increased biological effectiveness in particular at the end of their range and thus in the target volume. The spatial distribution of stopping particles can be monitored by means of PET-techniques making use of the small amount of radioactive projectile fragments. Ion beams were first used for medical applications in 1954 in Berkeley. Since then, several treatment facilities for tumour therapy have been established worldwide, and approximately 25 000 patients have been treated with protons and 3000 patients with heavier ions successfully. As an example, the specific advantages of the heavy ion therapy facility at GSI Darmstadt established in cooperation with the Radiological Clinics and DKFZ Heidelberg and FZ Rossendorf will be described. In contrast to most existing facilities, it is based on an active beam delivery system, using magnetic deflection of a pencil beam (raster scan) and accelerator energy variation to adjust the penetration depth. Thus, an optimal conformation of the dose to the target volume is achieved. PET-measurements allow for a quasi on-line monitoring of the 3D distribution of stopping particles and in particular of the position of the distal edge of the dose distribution. Furthermore, in the treatment planning procedure the radiobiological properties of ion beams are taken into account in great detail. In December 1997, patient treatments started at GSI, and up to now 42 patients were treated with carbon ions alone or in a mixed carbon/photon beam regime.

  18. Exploration des mécanismes de repliement des protéines par dynamique moléculaire

    NASA Astrophysics Data System (ADS)

    Gilquin, B.

    2005-11-01

    Comment se replient les protéines? Cette question est ancienne. En introduction nous rappellerons ce qu'est le paradoxe de Levinthal et comment on est passé de la notion de chemin de repliement à la notion de paysage énergétique. Les simulations de dynamique moléculaire ont permis d'aborder la compréhension du processus de repliement au niveau atomique. Cependant l'échelle de temps des processus de repliement (de l'ordre de la milliseconde) n'est pas accessible aux simulations numériques (de l'ordre de la nanoseconde). Plusieurs auteurs ont donc proposé de simuler le dépliement des protéines par dynamique moléculaire. En admettant le principe de micro-réversibilité l'étude du processus de dépliement renseigne sur celui de repliement. Cependant, il est nécessaire d'accélérer le dépliement en introduisant un biais afin que les états dépliées soient accessibles aux échelles de temps des simulations. Nous présenterons un exemple de ce qui a été réalise dans le cas de l'étude de protéines de petite taille suivant un repliement simple, globalement à deux états. Nous présenterons ensuite ce que nous avons réalisé dans le cas d'une protéine de taille plus importante et pour laquelle le processus de repliement est plus complexe car il existe un intermédiaire transitoire de repliement. C'est le cas du lysozyme pour lequel les simulations de dépliement permettent d'accéder au mécanisme atomique de repliement et de comprendre pourquoi des mutants de cette protéine se replient plus lentement et forment des fibres amyloïdiques. Ainsi les intermédiaires de repliement seraient à l'origine de formes pathogènes des protéines observées dans les maladies neuro-dégéneratives. Enfin nous montrerons comment à partir de plusieurs simulations longues de dynamique moléculaire, le paysage énergétique pour de petites protéines peut être calculé.

  19. The DES Science Verification weak lensing shear catalogues

    NASA Astrophysics Data System (ADS)

    Jarvis, M.; Sheldon, E.; Zuntz, J.; Kacprzak, T.; Bridle, S. L.; Amara, A.; Armstrong, R.; Becker, M. R.; Bernstein, G. M.; Bonnett, C.; Chang, C.; Das, R.; Dietrich, J. P.; Drlica-Wagner, A.; Eifler, T. F.; Gangkofner, C.; Gruen, D.; Hirsch, M.; Huff, E. M.; Jain, B.; Kent, S.; Kirk, D.; MacCrann, N.; Melchior, P.; Plazas, A. A.; Refregier, A.; Rowe, B.; Rykoff, E. S.; Samuroff, S.; Sánchez, C.; Suchyta, E.; Troxel, M. A.; Vikram, V.; Abbott, T.; Abdalla, F. B.; Allam, S.; Annis, J.; Benoit-Lévy, A.; Bertin, E.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Capozzi, D.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; Castander, F. J.; Clampitt, J.; Crocce, M.; Cunha, C. E.; D'Andrea, C. B.; da Costa, L. N.; DePoy, D. L.; Desai, S.; Diehl, H. T.; Doel, P.; Fausti Neto, A.; Flaugher, B.; Fosalba, P.; Frieman, J.; Gaztanaga, E.; Gerdes, D. W.; Gruendl, R. A.; Gutierrez, G.; Honscheid, K.; James, D. J.; Kuehn, K.; Kuropatkin, N.; Lahav, O.; Li, T. S.; Lima, M.; March, M.; Martini, P.; Miquel, R.; Mohr, J. J.; Neilsen, E.; Nord, B.; Ogando, R.; Reil, K.; Romer, A. K.; Roodman, A.; Sako, M.; Sanchez, E.; Scarpine, V.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Swanson, M. E. C.; Tarle, G.; Thaler, J.; Thomas, D.; Walker, A. R.; Wechsler, R. H.

    2016-08-01

    We present weak lensing shear catalogues for 139 square degrees of data taken during the Science Verification (SV) time for the new Dark Energy Camera (DECam) being used for the Dark Energy Survey (DES). We describe our object selection, point spread function estimation and shear measurement procedures using two independent shear pipelines, IM3SHAPE and NGMIX, which produce catalogues of 2.12 million and 3.44 million galaxies, respectively. We detail a set of null tests for the shear measurements and find that they pass the requirements for systematic errors at the level necessary for weak lensing science applications using the SV data. We also discuss some of the planned algorithmic improvements that will be necessary to produce sufficiently accurate shear catalogues for the full 5-yr DES, which is expected to cover 5000 square degrees.

  20. Peste des petits ruminants outbreaks in White Nile State, Sudan.

    PubMed

    Ishag, Osama M; Saeed, Intisar K; Ali, Yahia H

    2015-01-01

    Eight outbreaks of peste des petits ruminants in sheep and goats were reported in White Nile State, Sudan, between 2008 and 2009. A mortality rate of 4.2% was reported across the different outbreaks. Clinically the disease was characterised by high fever, ocular and nasal discharge, pneumonia, ulceration of the mucous membranes, diarrhoea and death. The postmortem findings included necrotic lesions in the mouth and gastrointestinal tract, and swollen, oedematous lymph nodes associated with the lungs and intestine. Of the 209 serum samples tested by competitive enzyme-linked immunosorbent assay, 113 (54%) were found positive. Peste des petits ruminants virus was confirmed in tissues, nasal swabs and blood samples by immunocapture enzyme-linked immunosorbent assay, reverse-transcription polymerase chain reaction and isolation of the virus in culture of lamb testicle cells. PMID:26304168

  1. Zweistufige Segmentierung des Tracheobronchialbaums mittels iterativen adaptiven Bereichswachstumsverfahren

    NASA Astrophysics Data System (ADS)

    Gergel, Ingmar; Wegner, Ingmar; Tetzlaff, Ralf; Meinzer, Hans-Peter

    Die Segmentierung des Tracheobronchialbaums aus medizinischen Bilddaten ist essentiell für unterschiedliche Anwendungen, beispielsweise der navigierten Bronchoskopie. Hierbei liegt das Hauptaugenmerk auf einer möglichst detaillierten Segmentierung der Bronchien bei möglichst geringer Laufzeit des Algorithmus. Dieser Beitrag beschreibt ein Verfahren, welches in zwei Schritten den Tracheobronchi-albaum anhand eines adaptiven Bereichswachstumsverfahrens aus CT-Aufnahmen segmentiert. Im ersten Schritt werden die großen Atemwege und im zweiten Schritt die kleinen Atemwege getrennt segmentiert. Insgesamt wird dadurch die Anzahl der Voxel, die von rechenaufwändigeren Algorithmen (bspw. Gefäß-Tracking) verarbeitet werden müssen, verringert. Die Ergebnisse zeigen bei minimaler Laufzeiterhöhung eine deutliche Steigerung der Anzahl sowie Tiefe der segmentierten Bronchien.

  2. Peste des petits ruminants outbreaks in White Nile State, Sudan.

    PubMed

    Ishag, Osama M; Saeed, Intisar K; Ali, Yahia H

    2015-08-21

    Eight outbreaks of peste des petits ruminants in sheep and goats were reported in White Nile State, Sudan, between 2008 and 2009. A mortality rate of 4.2% was reported across the different outbreaks. Clinically the disease was characterised by high fever, ocular and nasal discharge, pneumonia, ulceration of the mucous membranes, diarrhoea and death. The postmortem findings included necrotic lesions in the mouth and gastrointestinal tract, and swollen, oedematous lymph nodes associated with the lungs and intestine. Of the 209 serum samples tested by competitive enzyme-linked immunosorbent assay, 113 (54%) were found positive. Peste des petits ruminants virus was confirmed in tissues, nasal swabs and blood samples by immunocapture enzyme-linked immunosorbent assay, reverse-transcription polymerase chain reaction and isolation of the virus in culture of lamb testicle cells.

  3. The DES Science Verification Weak Lensing Shear Catalogs

    DOE PAGES

    Jarvis, M.

    2016-05-01

    We present weak lensing shear catalogs for 139 square degrees of data taken during the Science Verification (SV) time for the new Dark Energy Camera (DECam) being used for the Dark Energy Survey (DES). We describe our object selection, point spread function estimation and shear measurement procedures using two independent shear pipelines, IM3SHAPE and NGMIX, which produce catalogs of 2.12 million and 3.44 million galaxies respectively. We also detail a set of null tests for the shear measurements and find that they pass the requirements for systematic errors at the level necessary for weak lensing science applications using the SVmore » data. Furthermore, we discuss some of the planned algorithmic improvements that will be necessary to produce sufficiently accurate shear catalogs for the full 5-year DES, which is expected to cover 5000 square degrees.« less

  4. Partager : des technologies de pointe au service de la société

    SciTech Connect

    2011-02-14

    Médecine, climatologie, métrologie et informatique, les techniques utilisées par le LHC trouvent déjà des répercussions dans d’autres domaines scientifiques. Utilisant des techniques inédites, la physique des particules en fait bénéficier la société toute entière.

  5. Partager : des technologies de pointe au service de la société

    ScienceCinema

    None

    2016-07-12

    Médecine, climatologie, métrologie et informatique, les techniques utilisées par le LHC trouvent déjà des répercussions dans d’autres domaines scientifiques. Utilisant des techniques inédites, la physique des particules en fait bénéficier la société toute entière.

  6. Modelisations des effets de surface sur les jets horizontaux subsoniques d'hydrogene et de methane

    NASA Astrophysics Data System (ADS)

    Gomez, Luis Fernando

    Le developpement des codes et de normes bases sur une methodologie scientifique requiert la capacite de predire l'etendue inflammable de deversements gazeux d'hydrogene sous differentes conditions. Des etudes anterieures ont deja etabli des modeles bases sur les lois de conservation de la mecanique des fluides basees sur des correlations experimentales qui permettent de predire la decroissance de la concentration et de la vitesse d'un gaz le long de l'axe d'un jet libre vertical. Cette etude s'interesse aux effets de proximite a une surface horizontale parallele sur un jet turbulent. Nous nous interessons a son impact sur l'etendue du champ de la concentration et sur l'enveloppe inflammable en particulier. Cette etude est comparative : l'hydrogene est compare au methane. Ceci permet de degager l'influence des effets de difference de la densite sur le comportement du jet, et de comparer le comportement de l'hydrogene aux correlations experimentales, qui ont ete essentiellement etablies pour le methane. Un modele decrivant l'evolution spatio-temporelle du champ de concentration du gaz dilue est propose, base sur la mecanique des fluides computationnelle. Cette approche permet de varier systematiquement les conditions aux frontieres (proximite du jet a la surface, par exemple) et de connaitre en detail les proprietes de l'ecoulement. Le modele est implemente dans le code de simulations par volumes finis de FLUENT. Les resultats des simulations sont compares avec les lois de similitudes decoulant de la theorie des jets d'ecoulements turbulents libres ainsi qu'avec les resultats experimentaux disponibles. L'effet de la difference des masses molaires des constituantes du jet et des constituantes du milieu de dispersion est egalement etudie dans le contexte du comportement d'echelle de la region developpee du jet.

  7. Des recommandations probantes pour surveiller l’innocuité des antipsychotiques de deuxième génération chez les enfants et les adolescents

    PubMed Central

    Pringsheim, Tamara; Panagiotopoulos, Constadina; Davidson, Jana; Ho, Josephine

    2012-01-01

    HISTORIQUE : Au Canada, l’utilisation d’antipsychotiques, notamment les antipsychotiques de deuxième génération (ADG), a augmenté de façon considérable depuis cinq ans chez les enfants ayant des troubles de santé mentale. Ces médicaments ont le potentiel de causer de graves complications métaboliques et neurologiques lorsqu’on les utilise de manière chronique. OBJECTIF : Synthétiser les données probantes relatives aux effets secondaires métaboliques et neurologiques précis associés à l’usage d’ADG chez les enfants et fournir des recommandations probantes sur la surveillance de ces effets secondaires. MÉTHODOLOGIE : Les auteurs ont procédé à une analyse systématique des essais cliniques contrôlés des ADG auprès d’enfants. Ils ont fait des recommandations à l’égard de la surveillance de l’innocuité des ADG d’après un modèle de classification fondé sur le système GRADE (système de notation de l’évaluation et de l’élaboration des recommandations). Lorsque les données probantes n’étaient pas suffisantes, ils fondaient leurs recommandations sur le consensus et l’avis d’experts. Un groupe consensuel multidisciplinaire a analysé toutes les données probantes pertinentes et est parvenu à un consensus à l’égard des recommandations. RÉSULTATS : Les recommandations probantes portant sur la surveillance de l’innocuité des ADG figurent dans les présentes lignes directrices. Les auteurs indiquent la qualité des recommandations relatives à des examens physiques et tests de laboratoire précis à l’égard de chaque ADG à des moments déterminés. CONCLUSION : De multiples essais aléatoires et contrôlés ont permis d’évaluer l’efficacité de bon nombre des ADG utilisés pour traiter les troubles de santé mentale en pédiatrie. Toutefois, leurs avantages ne sont pas sans risques : on observe à la fois des effets secondaires métaboliques et neurologiques chez les enfants traités au moyen d

  8. Loss of Internal Backbone Carbonyls: Additional Evidence for Sequence-Scrambling in Collision-Induced Dissociation of y-Type Ions

    NASA Astrophysics Data System (ADS)

    Harper, Brett; Miladi, Mahsan; Solouki, Touradj

    2014-10-01

    It is shown that y-type ions, after losing C-terminal H2O or NH3, can lose an internal backbone carbonyl (CO) from different peptide positions and yield structurally different product fragment ions upon collision-induced dissociation (CID). Such CO losses from internal peptide backbones of y-fragment ions are not unique to a single peptide and were observed in four of five model peptides studied herein. Experimental details on examples of CO losses from y-type fragment ions for an isotopically labeled AAAAH AA-NH2 heptapeptide and des-acetylated-α-melanocyte-stimulating hormone (dα-MSH) (SYSMEHFRWGKPV-NH2) are reported. Results from isotope labeling, tandem mass spectrometry (MSn), and ion mobility-mass spectrometry (IM-MS) confirm that CO losses from different amino acids of m/ z-isolated y-type ions yield structurally different ions. It is shown that losses of internal backbone carbonyls (as CID products of m/ z-isolated y-type ions) are among intermediate steps towards formation of rearranged or permutated product fragment ions. Possible mechanisms for generation of the observed sequence-scrambled a-"like" ions, as intermediates in sequence-scrambling pathways of y-type ions, are proposed and discussed.

  9. Clues From Pluto's Ions

    NASA Astrophysics Data System (ADS)

    Kohler, Susanna

    2016-05-01

    Nearly a year ago, in July 2015, the New Horizons spacecraft passed by the Pluto system. The wealth of data amassed from that flyby is still being analyzed including data from the Solar Wind Around Pluto (SWAP) instrument. Recent examination of this data has revealedinteresting new information about Plutos atmosphere and how the solar wind interacts with it.A Heavy Ion TailThe solar wind is a constant stream of charged particles released by the Sun at speeds of around 400 km/s (thats 1 million mph!). This wind travels out to the far reaches of the solar system, interacting with the bodies it encounters along the way.By modeling the SWAP detections, the authors determine the directions of the IMF that could produce the heavy ions detected. Red pixels represent IMF directions permitted. No possible IMF could reproduce the detections if the ions are nitrogen (bottom panels), and only retrograde IMF directions can produce the detections if the ions are methane. [Adapted from Zirnstein et al. 2016]New Horizons data has revealed that Plutos atmosphere leaks neutral nitrogen, methane, and carbon monoxide molecules that sometimes escape its weak gravitational pull. These molecules become ionized and are subsequently picked up by the passing solar wind, forming a tail of heavy ions behind Pluto. The details of the geometry and composition of this tail, however, had not yet been determined.Escaping MethaneIn a recent study led by Eric Zirnstein (Southwest Research Institute), the latest analysis of data from the SWAP instrument on board New Horizons is reported. The team used SWAPs ion detections from just after New Horizons closest approach to Pluto to better understand how the heavy ions around Pluto behave, and how the solar wind interacts with Plutos atmosphere.In the process of analyzing the SWAP data, Zirnstein and collaborators first establish what the majority of the heavy ions picked up by the solar wind are. Models of the SWAP detections indicate they are unlikely

  10. Simulations of the OzDES AGN reverberation mapping project

    DOE PAGES

    King, Anthea L.; Martini, Paul; Davis, Tamara M.; Denney, K. D.; Kochanek, C. S.; Peterson, Bradley M.; Skielboe, Andreas; Vestergaard, Marianne; Huff, Eric; Watson, Darach; et al

    2015-08-26

    As part of the Australian spectroscopic dark energy survey (OzDES) we are carrying out a large-scale reverberation mapping study of ~500 quasars over five years in the 30 deg2 area of the Dark Energy Survey (DES) supernova fields. These quasars have redshifts ranging up to 4 and have apparent AB magnitudes between 16.8 mag < r < 22.5 mag. The aim of the survey is to measure time lags between fluctuations in the quasar continuum and broad emission-line fluxes of individual objects in order to measure black hole masses for a broad range of active galactic nuclei (AGN) and constrainmore » the radius–luminosity (R–L) relationship. Here we investigate the expected efficiency of the OzDES reverberation mapping campaign and its possible extensions. We expect to recover lags for ~35–45 % of the quasars. AGN with shorter lags and greater variability are more likely to yield a lag measurement, and objects with lags ≲6 months or ~1 yr are expected to be recovered the most accurately. The baseline OzDES reverberation mapping campaign is predicted to produce an unbiased measurement of the R–L relationship parameters for Hβ, MgIIλ2798, and C IVλ1549. As a result, extending the baseline survey by either increasing the spectroscopic cadence, extending the survey season, or improving the emission-line flux measurement accuracy will significantly improve the R–L parameter constraints for all broad emission lines.« less

  11. Einstein à l'épreuve des faits

    NASA Astrophysics Data System (ADS)

    Bonnet-Bidaud, J. M.

    1998-02-01

    Apres plus de 80 ans d'existence, la theorie d'Einstein cherche encore des preuves, bien que plusieurs de ses predictions aient ete deja verifiees avec une incroyable precision et certains de ses effets les plus spectaculaires reconnus de facon indeniable. Plusieurs missions parmi les plus complexes jamais envisagees sont en projet ou en cours de construction dans le but unique de verifier la relativite. Pourquoi cet enjeu est-il capital pour la physique contemporaine ?

  12. Landform Variability in the Chaine Des Puys Tracing Multiple Processes

    NASA Astrophysics Data System (ADS)

    van Wyk de Vries, B.; Grosse, P.

    2014-12-01

    The Chaîne des Puys is a highly varied, type monogenetic field, and was acknowledged by 38th WH UNESCO Committee to contain Outstanding Universal Value. The Chaîne des Puys - Limagne Fault should be presented in 2016 for World Heritage Status. The 30 km long Chaîne des Puys contains ranges from simple basaltic scoria cones to complex, multicrater cones, and small simple domes to complicated trachytic edifices. There is also a range of phreatomagmatic landforms from tuff rings to maars and vulcanian to sub plinian deposits. There is a wide range of pahoehoe and aa lava types, that have flowed over different topographies. Here we take morphometrical data to analyse the variability of the edifices using a 10 m regional topographic DTM. The volcanoes form a broad continuum of morphological features, and height/widths of domes and cones overlap. Some edifices, are smooth and elliptical, even though they have erupted complex lava sequences, while others complex shapes, but are related to simple lava flows. There seems to be no easy correlation between cone morphology and eruption histories derived from lava fields and distal tephras. In the few cones where the interior is visible, the shape of the cone is seen to vary with changing eruption events. The final shape is a combination of changing activity, with the last events having the strongest morphometic signature. The broad variations in edifice, lava field, and deposit morphology are described and quantified, however it becomes clear from the few individual eruptions already studied, that to fully appreciate the range of monogenetic eruption scenarios presented by the Chaîne des Puys, much more detailed work is required. This is being made possible by new acquisitions of LiDAR imagery, new geophysical work, and the combination of excellent preservation and extensive outcrop that is partly the result the original geology and long term responsible land management by the local populace, regional park and local

  13. Gestion des plaines inondables: Hauteur ou débit

    NASA Astrophysics Data System (ADS)

    El-Jabi, Nassir; Rousselle, Jean

    1983-07-01

    A stochastic model based on the recent developments in the theory of extreme values is presented to describe the flood occurrence. This model is applied to the "Rivière des Prairies", assuming that the exceedances (flood peak and/or stage above a given base flow and/or base stage) are independent and identically distributed in the time interval for a given year and season.

  14. Discovery and Classification of DES15S2lam

    NASA Astrophysics Data System (ADS)

    Pan, Y.-C.; Foley, R. J.; Nichol, R.; Papadopoulos, A.; Childress, M.; D'Andrea, C.; Smith, M.; Sullivan, M.; Maartens, R.; Gupta, R.; Kovacs, E.; Kuhlmann, S.; Spinka, H.; Ahn, E.; Finley, D. A.; Frieman, J.; Marriner, J.; Wester, W.; Aldering, G.; Kim, A. G.; Thomas, R. C.; Barbary, K.; Bloom, J. S.; Goldstein, D.; Nugent, P.; Perlmutter, S.; Casas, R.; Castander, F. J.; Desai, S.; Paech, K.; Smith, R. C.; Schubnell, M.; Kessler, R.; Lasker, J.; Scolnic, D.; Brout, D. J.; Gladney, L.; Sako, M.; Wolf, R. C.; Brown, P. J.; Krisciunas, K.; Suntzeff, N.

    2015-10-01

    We report optical spectroscopy of DES15S2lam discovered by the Dark Energy Survey. The spectrum (540-965nm) was obtained using GMOS on Gemini-North. Object classification was performed using superfit (Howell et al, 2005, ApJ, 634, 1190) and SNID (Blondin & Tonry, 2007, ApJ, 666, 1024), the details of which are reported in the table below.

  15. La dysplasie fibreuse: état des lieux

    PubMed Central

    Akasbi, Nessrine; Abourazzak, Fatima Ezzahra; Talbi, Sofia; Tahiri, Latifa; Harzy, Taoufik

    2015-01-01

    La dysplasie fibreuse des os est une affection osseuse bénigne congénitale mais non héréditaire, où l'os normal est remplacé par un tissu fibreux renfermant une ostéogenèse immature. Elle est due à une mutation du gène GNAS 1sur le chromosome 20q13, une mutation activatrice de la sous-unité α de la protéine G. C'est une pathologie qui est le plus souvent silencieuse, de découverte fortuite sur une radiographie standard ou révélée par une douleur osseuse ou une fracture pathologique. L'imagerie et l'histologie, quand elle est nécessaire, permettent d’établir le diagnostic. Bien qu'il ne s'agisse pas d'une tumeur, elle est souvent classée dans la catégorie des tumeurs osseuses bénignes pour des raisons de diagnostic différentiel radiographique et anatomopathologique. Elle peut être monostotique ou polyostotique. L'approche thérapeutique est essentiellement symptomatique. Quelques publications récentes ont suggéré l'intérêt majeur d'un bisphosphonate, en particulier le pamidronate, qui diminuerait les douleurs et stimulerait une reminéralisation progressive des zones ostéolytiques chez les patients traités. D'autres traitements tels que la thérapie ciblée sont en cours d’évaluation. PMID:26401215

  16. Evolution of Bacillus subtilis to enhanced growth at low pressure: up-regulated transcription of des-desKR, encoding the fatty acid desaturase system.

    PubMed

    Fajardo-Cavazos, Patricia; Waters, Samantha M; Schuerger, Andrew C; George, Sheeja; Marois, James J; Nicholson, Wayne L

    2012-03-01

    The atmospheric pressure on Mars ranges from 1-10 mbar, about 1% of Earth pressure (∼1013 mbar). Low pressure is a growth-inhibitory factor for terrestrial microorganisms on Mars, and a putative low-pressure barrier for growth of Earth bacteria of ∼25 mbar has been postulated. In a previous communication, we described the isolation of a strain of Bacillus subtilis that had evolved enhanced growth ability at the near-inhibitory low pressure of 50 mbar. To explore mechanisms that enabled growth of the low-pressure-adapted strain, numerous genes differentially transcribed between the ancestor strain WN624 and low-pressure-evolved strain WN1106 at 50 mbar were identified by microarray analysis. Among these was a cluster of three candidate genes (des, desK, and desR), whose mRNA levels in WN1106 were higher than the ancestor on the microarrays. Up-regulation of these genes was confirmed by quantitative reverse transcription-polymerase chain reaction (qRT-PCR) analysis. The des, desK, and desR genes encode the Des membrane fatty acid (FA) desaturase, the DesK sensor kinase, and the DesR response regulator, respectively, which function to maintain membrane fluidity in acute response to temperature downshift. Pressure downshift caused an up-regulation of des mRNA levels only in WN1106, but expression of a des-lacZ transcriptional fusion was unaffected, which suggests that des regulation was different in response to temperature versus pressure downshift. Competition experiments showed that inactivation of the des gene caused a slight, but statistically significant, loss of fitness of strain WN1106 at 50 mbar. Further, analysis of membrane FA composition of cells grown at 1013 versus 50 mbar revealed a decrease in the ratio of unsaturated to saturated FAs but an increase in the ratio of anteiso- to iso-FAs. The present study represents a first step toward identification of molecular mechanisms by which B. subtilis could sense and respond to the novel environmental stress

  17. Ion temperature gradient driven turbulence with strong trapped ion resonance

    SciTech Connect

    Kosuga, Y.; Itoh, S.-I.; Diamond, P. H.; Itoh, K.; Lesur, M.

    2014-10-15

    A theory to describe basic characterization of ion temperature gradient driven turbulence with strong trapped ion resonance is presented. The role of trapped ion granulations, clusters of trapped ions correlated by precession resonance, is the focus. Microscopically, the presence of trapped ion granulations leads to a sharp (logarithmic) divergence of two point phase space density correlation at small scales. Macroscopically, trapped ion granulations excite potential fluctuations that do not satisfy dispersion relation and so broaden frequency spectrum. The line width from emission due only to trapped ion granulations is calculated. The result shows that the line width depends on ion free energy and electron dissipation, which implies that non-adiabatic electrons are essential to recover non-trivial dynamics of trapped ion granulations. Relevant testable predictions are summarized.

  18. Cassini observations of ion cyclotron waves and ions anisotropy

    NASA Astrophysics Data System (ADS)

    Crary, F. J.; Dols, V. J.; Cassidy, T. A.; Tokar, R. L.

    2013-12-01

    In Saturn's equatorial, inner magnetosphere, the production of fresh ions in a pick-up distribution generates ion cyclotron waves. These waves are a sensitive indicator of fresh plasma production, but the quantitative relation between wave properties and ionization rates is nontrivial. We present a combined analysis of Cassini MAG and CAPS data, from a variety of equatorial orbits between 2005 and 2012. Using the MAG data, we determine the amplitude and peak frequency of ion cyclotron waves. From the CAPS data we extract the parallel and perpendicular velocity distribution of water group ions. We compare these results with hybrid simulations of the ion cyclotron instability and relate the observed wave amplitudes and ion velocity distributions to the production rate of pickup ions. The resulting relation between wave and plasma properties will allow us to infer ion production rates even at times when no direct ion measurements are available.

  19. Molecular ion photofragment spectroscopy

    SciTech Connect

    Bustamente, S.W.

    1983-11-01

    A new molecular ion photofragment spectrometer is described which features a supersonic molecular beam ion source and a radio frequency octapole ion trap interaction region. This unique combination allows several techniques to be applied to the problem of detecting a photon absorption event of a molecular ion. In particular, it may be possible to obtain low resolution survey spectra of exotic molecular ions by using a direct vibrational predissociation process, or by using other more indirect detection methods. The use of the spectrometer is demonstrated by measuring the lifetime of the O/sub 2//sup +/(/sup 4/..pi../sub u/) metastable state which is found to consist of two main components: the /sup 4/..pi../sub 5/2/ and /sup 4/..pi../sub -1/2/ spin components having a long lifetime (approx. 129 ms) and the /sup 4/..pi../sub 3/2/ and /sup 4/..pi../sub 1/2/ spin components having a short lifetime (approx. 6 ms).

  20. Ion Milling of Sapphire

    NASA Technical Reports Server (NTRS)

    Gregory, Don A.

    2002-01-01

    The ion figuring system at the Marshall Space Flight Center has been successfully used for at least three previous investigations into the ion milling of metals. The research was directed toward improving the surface quality of X-ray directing optics. These studies were performed on surfaces that were already hand polished to an excellent surface quality and were intended to remove the residual unwanted figure left by those techniques. The ion milling was typically carried out on test surfaces or mandrels that were several centimeters in width and length. The good thermal conductivity of the metal samples allowed the ion beam to be directed onto the sample for an indefinite period of time. This is not true of sapphire or most electrical insulators and problems have arisen in recent attempts to ion mill thin samples of sapphire. The failure and fracture of the material was likely due to thermal stresses and the relatively low thermal conductivity of sapphire (compared to most metals), These assumed stresses actually provided the key as to how they might be monitored. A thermal gradient in the sapphire sample will induce an effective index of refraction change and because of the shape constraint and the crystal structure and simple thermal expansion, this index change will be nonuniform across the sample. In all but simple cubic crystal structures, this leads to a spatially nonuniform optical retardance induced on any polarized optical beam traversing the sample, and it is this retardance that can be monitored using standard polarimetric procedures.

  1. Ion transport in pigmentation

    PubMed Central

    Bellono, Nicholas W.; Oancea, Elena V.

    2014-01-01

    Skin melanocytes and ocular pigment cells contain specialized organelles called melanosomes, which are responsible for the synthesis of melanin, the major pigment in mammals. Defects in the complex mechanisms involved in melanin synthesis and regulation result in vision and pigmentation deficits, impaired development of the visual system,, and increased susceptibility to skin and eye cancers. Ion transport across cellular membranes is critical for many biological processes, including pigmentation, but the molecular mechanisms by which it regulates melanin synthesis, storage, and transfer are not understood. In this review we first discuss ion channels and transporters that function at the plasma membrane of melanocytes; in the second part we consider ion transport across the membrane of intracellular organelles, with emphasis on melanosomes. We discuss recently characterized lysosomal and endosomal ion channels and transporters associated with pigmentation phenotypes. We then review the evidence for melanosomal channels and transporters critical for pigmentation, discussing potential molecular mechanisms mediating their function. The studies investigating ion transport in pigmentation physiology open new avenues for future research and could reveal novel molecular mechanisms underlying melanogenesis. PMID:25034214

  2. Ion Beam Epitaxy

    NASA Astrophysics Data System (ADS)

    Yamada, I.

    The following sections are included: * FILM FORMATION BY ION BEAMS * Fundamental Processes in Film Formation by Low Energy Ion Beams * Comparison of ICB with Other Physical Vapor Deposition Methods * Vacuum Deposition * Sputter Deposition * Ion Plating * Ion Beam Deposition * Simultaneous Deposition and Implantation * Plasma Enhanced Deposition * Section I References * ION CLUSTER BEAM DEPOSITION AND CLUSTER BEAM FORMATION * Nucleation Process * Growth and Condensation Process * Section II References * CHARACTERISTICS OF THE CLUSTER * Velocity of Clusters * Energy of Clusters * TEM Observation of Clusters * Structural Properties * Section III References * IONIZED CLUSTER BEAM DEPOSITION SYSTEM * Section IV References * FILM DEPOSITION PROCESS BY ICB * Fundamental Process * Effects of Kinetic Energy on the Film Properties * Epitaxial phenomena * Crystallographic Structure * Physical Structure of Films * Effects of the Electric Charge on the Film Properties * Section V References * APPLICATIONS * Silicon and Silicon Alloy Films * Low Temperature Epitaxy of Silicon Films * Thermally Stable a-Si Film Growth * High Quality SiO2 Film Deposition * Epitaxial A1 Films * Electromigration Resistant A1 Film * Thermally Stable Al/Si Contact * II-VI and III-V Compound Films * Thin Multiple Layered Film * CONCLUSIONS * Acknowledgements * Section VI References

  3. ION Configuration Editor

    NASA Technical Reports Server (NTRS)

    Borgen, Richard L.

    2013-01-01

    The configuration of ION (Inter - planetary Overlay Network) network nodes is a manual task that is complex, time-consuming, and error-prone. This program seeks to accelerate this job and produce reliable configurations. The ION Configuration Editor is a model-based smart editor based on Eclipse Modeling Framework technology. An ION network designer uses this Eclipse-based GUI to construct a data model of the complete target network and then generate configurations. The data model is captured in an XML file. Intrinsic editor features aid in achieving model correctness, such as field fill-in, type-checking, lists of valid values, and suitable default values. Additionally, an explicit "validation" feature executes custom rules to catch more subtle model errors. A "survey" feature provides a set of reports providing an overview of the entire network, enabling a quick assessment of the model s completeness and correctness. The "configuration" feature produces the main final result, a complete set of ION configuration files (eight distinct file types) for each ION node in the network.

  4. Ion transport in pigmentation.

    PubMed

    Bellono, Nicholas W; Oancea, Elena V

    2014-12-01

    Skin melanocytes and ocular pigment cells contain specialized organelles called melanosomes, which are responsible for the synthesis of melanin, the major pigment in mammals. Defects in the complex mechanisms involved in melanin synthesis and regulation result in vision and pigmentation deficits, impaired development of the visual system, and increased susceptibility to skin and eye cancers. Ion transport across cellular membranes is critical for many biological processes, including pigmentation, but the molecular mechanisms by which it regulates melanin synthesis, storage, and transfer are not understood. In this review we first discuss ion channels and transporters that function at the plasma membrane of melanocytes; in the second part we consider ion transport across the membrane of intracellular organelles, with emphasis on melanosomes. We discuss recently characterized lysosomal and endosomal ion channels and transporters associated with pigmentation phenotypes. We then review the evidence for melanosomal channels and transporters critical for pigmentation, discussing potential molecular mechanisms mediating their function. The studies investigating ion transport in pigmentation physiology open new avenues for future research and could reveal novel molecular mechanisms underlying melanogenesis.

  5. [Ion specificity during ion exchange equilibrium in natural clinoptilolite].

    PubMed

    He, Yun-Hua; Li, Hang; Liu, Xin-Min; Xiong, Hai-Ling

    2015-03-01

    Zeolites have been widely applied in soil improvement and environment protection. The study on ion specificity during ion exchange equilibrium is of important significance for better use of zeolites. The maximum adsorption capacities of alkali ions during ion exchange equilibrium in the clinoptilolite showed obvious specificity. For alkali metal ions with equivalent valence, the differences in adsorption capacity increased with the decrease of ionic concentration. These results cannot be well explained by the classical theories including coulomb force, ionic size, hydration, dispersion force, classic induction force and surface complexation. We found that the coupling of polarization effects resulted from the quantum fluctuation of diverse alkali metal ions and electric field near the zeolite surface should be the primary reason for specific ion effect during ion exchange in zeolite. The result of this coupling effect was that the difference in the ion dipole moment increased with the increase of surface potential, which further expanded the difference in the adsorption ability between zeolite surface and ions, resulting in different ion exchange adsorption ability at the solid/liquid interface. Due to the high surface charge density of zeolite, ionic size also played an important role in the distribution of ions in the double diffuse layer, which led to an interesting result that distinct differences in exchange adsorption ability of various alkali metal ions were only detected at high surface potential (the absolute value was greater than 0.2 V), which was different from the ion exchange equilibrium result on the surface with low charge density.

  6. Experimental study of particle formation by ion-ion recombination.

    PubMed

    Nagato, Kenkichi; Nakauchi, Masataka

    2014-10-28

    Particle formation by ion-ion recombination has been studied using an ion-ion recombination drift tube (IIR-DT). IIR-DT uses two DC corona ionizers to produce positive and negative ions at the ends of the drift tube. The ions of different polarity move in opposite directions along the electric field in the drift tube. We observed significant particle formation using ions generated in purified air containing H2O, SO2, and NH3. Particle formation was suppressed when no drift field was applied. We also observed few particles when we used a single discharge (positive or negative only). These results clearly show that particle formation observed in the IIR-DT was caused by nucleation by ion-ion recombination. Positive and negative ion species produced by corona ionizers were investigated using an atmospheric pressure ionization mass spectrometer. The ions involved in the particle formation were suggested to include H3O(+)(H2O)n and NH4(+)(H2O)n for positive ions and sulfur-based ions such as SO5(-), SO5(-)NO2, and HSO4(-) for negative ions. PMID:25362301

  7. Electronuclear ion fusion in an ion cyclotron resonance reactor

    SciTech Connect

    Cowgill, Donald F.

    1996-12-01

    A method and apparatus for generating nuclear fusion by ion cyclotron resonance in an ion trap reactor. The reactor includes a cylindrical housing having an axial axis, an internal surface, and first and second ends. First and second end plates that are charged are respectively located at the first and second ends of the cylindrical housing. A gas layer is adsorbed on the internal surface of the cylindrical housing. Ions are desorbed from the gas layer, forming a plasma layer adjacent to the cylindrical housing that includes first ions that have a same charge sign as the first and second end plates. A uniform magnetic field is oriented along the axial axis of the cylindrical housing. Second ions, that are unlike the first ions, but have the same charge sign, are injected into the cylindrical housing along the axial axis of the cylindrical housing. A radio frequency field resonantly accelerates the injected second ions at the cyclotron resonance frequency of the second ions. The second ions circulate in increasing helical orbits and react with the first ions, at the optimum energy for nuclear fusion. The amplitude of the radio frequency field is adjusted to accelerate the second ions at a rate equal to the rate of tangential energy loss of the second ions by nuclear scattering in the first ions, causing the ions to continually interact until fusion occurs.

  8. New Cs sputter ion source with polyatomic ion beams for secondary ion mass spectrometry applications

    NASA Astrophysics Data System (ADS)

    Belykh, S. F.; Palitsin, V. V.; Veryovkin, I. V.; Kovarsky, A. P.; Chang, R. J. H.; Adriaens, A.; Dowsett, M. G.; Adams, F.

    2007-08-01

    A simple design for a cesium sputter ion source compatible with vacuum and ion-optical systems as well as with electronics of the commercially available Cameca IMS-4f instrument is reported. This ion source has been tested with the cluster primary ions of Sin- and Cun-. Our experiments with surface characterization and depth profiling conducted to date demonstrate improvements of the analytical capabilities of the secondary ion mass spectrometry instrument due to the nonadditive enhancement of secondary ion emission and shorter ion ranges of polyatomic projectiles compared to atomic ones with the same impact energy.

  9. Approche à l’endroit des blessures traumatiques à la main en soins primaires

    PubMed Central

    Cheung, Kevin; Hatchell, Alexandra; Thoma, Achilleas

    2013-01-01

    Résumé Objectif Passer en revue la prise en charge initiale des blessures traumatiques communes à la main que voient les médecins de soins primaires. Sources des données Nous avons examiné les données cliniques probantes et les ouvrages spécialisés récents cernés par des recherches dans la base de données électronique MEDLINE. Nous avons utilisé l’opinion d’experts pour compléter les recommandations dans les domaines où les données scientifiques étaient rares. Message principal Les médecins de soins primaires sont couramment appelés à prendre en charge des patients victimes de blessures traumatiques à la main. Dans le contexte d’un cas clinique, nous examinons l’évaluation, le diagnostic et la prise en charge initiale des traumatismes communs à la main. La présentation et la prise en charge des blessures au lit de l’ongle, des amputations de l’extrémité du doigt, des doigts en maillet, des fractures à la main, des lacérations de tendons, des morsures et de la ténosynovite infectieuse seront aussi discutées. Les principes de la prise en charge des blessures traumatiques à la main comportent la réduction et l’immobilisation des fractures, la prescription d’imagerie radiographique post-réduction, l’obtention d’un recouvrement par les tissus mous, la prévention et le traitement des infections et l’assurance d’une prophylaxie antitétanique. Conclusion Il est essentiel d’assurer une évaluation et une prise en charge appropriées des blessures traumatiques à la main pour prévenir une morbidité considérable à long terme dans une population autrement en santé. La reconnaissance sans délai des blessures qui nécessitent une demande de consultation urgente ou rapide auprès d’un chirurgien spécialiste de la main est également critique.

  10. [Influence of diethyl sulfate (DES) mutagenesis on growth properties and pigment secondary metabolites of Phellinus igniarius].

    PubMed

    Wang, Jing; Wu, Xin-yuan; Ma, Wei; Chen, Jing; Liu, Cheng; Wu, Xiu-li

    2015-06-01

    The diethyl sulfate (DES) mutagenesis was chosen for the mutagenic treatment to Phellinus igniarius, and the relationship of mutagenesis time and death rate was investigated with 0.5% DES. The differences of mycelial growth speed, liquid fermentation mycelia biomass, morphology and pigment classes of secondary metabolites production speed and antioxidant activities of metabolite products were discussed. The study displayed that DES mutagenesis could change mycelial morphology without obvious effect on mycelium growth, and the DES mutagenesis improved antioxidant activities of the active ingredients of P. igniarius and had more antioxidant activity of hypoxia/sugar PC12 nerve cells than that of P. igniarius. PMID:26591512

  11. C and D comes curbside in Des Moines

    SciTech Connect

    Cox, C.

    1997-07-01

    Until last October, virtually all the commingled construction and demolition (C and D) waste in Des Moines, Iowa, was being landfilled. But thanks to a $483,000 grant from the state and the financial commitment of two local solid waste businesses, overall diversion rates of C and D waste have gone from 20% to 50%, and are still climbing as the construction season shifts into high gear. It is a demonstration project initiated by Iowa`s Department of Natural Resources (DNR). In the late 1980s, the state passed legislation that called for a goal of 50% of all solid waste to be diverted from landfills by 2000. Last October, the grant was awarded to the Corell Team, a joint effort comprising Central Recycling, a unit of Corell Contractor (Des Moines, Iowa), Corell itself, and Artistic Waste Services, Inc. (Des Moines, Iowa). The uniqueness of the project is its degree of vertical integration, from the collection and transport of C and D waste to its recycling, marketing, and disposal. Artistic collects, presorts recoverable commodities, and hauls them to its own markets or to Central Recycling for further sorting and recycling. Central, using a Re-Tech (Myerstown, Pa.) trommel and a 12-man picking crew, further sorts and recycles materials.

  12. CMB lensing tomography with the DES Science Verification galaxies

    NASA Astrophysics Data System (ADS)

    Giannantonio, T.; Fosalba, P.; Cawthon, R.; Omori, Y.; Crocce, M.; Elsner, F.; Leistedt, B.; Dodelson, S.; Benoit-Lévy, A.; Gaztañaga, E.; Holder, G.; Peiris, H. V.; Percival, W. J.; Kirk, D.; Bauer, A. H.; Benson, B. A.; Bernstein, G. M.; Carretero, J.; Crawford, T. M.; Crittenden, R.; Huterer, D.; Jain, B.; Krause, E.; Reichardt, C. L.; Ross, A. J.; Simard, G.; Soergel, B.; Stark, A.; Story, K. T.; Vieira, J. D.; Weller, J.; Abbott, T.; Abdalla, F. B.; Allam, S.; Armstrong, R.; Banerji, M.; Bernstein, R. A.; Bertin, E.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Capozzi, D.; Carlstrom, J. E.; Carnero Rosell, A.; Carrasco Kind, M.; Castander, F. J.; Chang, C. L.; Cunha, C. E.; da Costa, L. N.; D'Andrea, C. B.; DePoy, D. L.; Desai, S.; Diehl, H. T.; Dietrich, J. P.; Doel, P.; Eifler, T. F.; Evrard, A. E.; Neto, A. Fausti; Fernandez, E.; Finley, D. A.; Flaugher, B.; Frieman, J.; Gerdes, D.; Gruen, D.; Gruendl, R. A.; Gutierrez, G.; Holzapfel, W. L.; Honscheid, K.; James, D. J.; Kuehn, K.; Kuropatkin, N.; Lahav, O.; Li, T. S.; Lima, M.; March, M.; Marshall, J. L.; Martini, P.; Melchior, P.; Miquel, R.; Mohr, J. J.; Nichol, R. C.; Nord, B.; Ogando, R.; Plazas, A. A.; Romer, A. K.; Roodman, A.; Rykoff, E. S.; Sako, M.; Saliwanchik, B. R.; Sanchez, E.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thaler, J.; Thomas, D.; Vikram, V.; Walker, A. R.; Wechsler, R. H.; Zuntz, J.

    2016-03-01

    We measure the cross-correlation between the galaxy density in the Dark Energy Survey (DES) Science Verification data and the lensing of the cosmic microwave background (CMB) as reconstructed with the Planck satellite and the South Pole Telescope (SPT). When using the DES main galaxy sample over the full redshift range 0.2 < zphot < 1.2, a cross-correlation signal is detected at 6σ and 4σ with SPT and Planck , respectively. We then divide the DES galaxies into five photometric redshift bins, finding significant (>2σ) detections in all bins. Comparing to the fiducial Planck cosmology, we find the redshift evolution of the signal matches expectations, although the amplitude is consistently lower than predicted across redshift bins. We test for possible systematics that could affect our result and find no evidence for significant contamination. Finally, we demonstrate how these measurements can be used to constrain the growth of structure across cosmic time. We find the data are fit by a model in which the amplitude of structure in the z < 1.2 universe is 0.73 ± 0.16 times as large as predicted in the Λ cold dark matter Planck cosmology, a 1.7σ deviation.

  13. CMB lensing tomography with the DES Science Verification galaxies

    DOE PAGES

    Giannantonio, T.

    2016-01-07

    We measure the cross-correlation between the galaxy density in the Dark Energy Survey (DES) Science Verification data and the lensing of the cosmic microwave background (CMB) as reconstructed with the Planck satellite and the South Pole Telescope (SPT). When using the DES main galaxy sample over the full redshift range 0.2 < zphot < 1.2, a cross-correlation signal is detected at 6σ and 4σ with SPT and Planck respectively. We then divide the DES galaxies into five photometric redshift bins, finding significant (>2σ) detections in all bins. Comparing to the fiducial Planck cosmology, we find the redshift evolution of themore » signal matches expectations, although the amplitude is consistently lower than predicted across redshift bins. We test for possible systematics that could affect our result and find no evidence for significant contamination. Finally, we demonstrate how these measurements can be used to constrain the growth of structure across cosmic time. We find the data are fit by a model in which the amplitude of structure in the z < 1.2 universe is 0.73 ± 0.16 times as large as predicted in the LCDM Planck cosmology, a 1.7σ deviation.« less

  14. Infections fongiques des brûlé : revue

    PubMed Central

    Arnould, JF.; Le Floch, R.

    2015-01-01

    Summary Les infections fongiques locales ou générales sont souvent d’une extrême gravité chez les brûlés. Les brûlés combinent de nombreux facteurs de risque à une immunodépression induite par la brûlure. Les infections de plaies sont le fait des genres Candida, Aspergillus et des agents de mucormycoses. Ces deux derniers cas sont à l’origine de lésions particulièrement sévères. Leur diagnostic repose sur la biopsie cutanée avec examens mycologique et anatomopathologique. Le traitement est essentiellement chirurgical, associé à une antibiothérapie adaptée. Les septicémies sont le fait de levures, essentiellement du genre Candida. Le diagnostic en est difficile dans le contexte des brûlés et repose souvent sur une forte suspicion clinique. Leur traitement repose sur les échinocandines et plus secondairement sur le fluconazole. PMID:26668558

  15. Transposition des processus membranaires biologiques aux traitements des effluents métallifères peu chargés. Conception et étude chimique d'une pompe ionique uranifère. Transport, contre-transport, couplage positif

    NASA Astrophysics Data System (ADS)

    Hasaine-Sadi, F.; Benhassaine, A.; Ait-Amar, H.

    1999-09-01

    An ionic pump has been devided thanks to au “liquid-liquid" extraction-reextration where the extraction compartment and the reextraction compartment are put in contact with one another through the membrane composed of an mediator diluted in the kerosene. We have applied this process to the system: uranyle nitrate, nitric acid-phosphate tributyle, kerosene-sodium carbonate. Interesting performances have been realised for diluted solutions (100 ppm). The chemicals parameters has allowed to obtain the variables giving the extraction and reextraction efficiency optimum. A chemical modelisation has allowed to identify the extraction mechanism. The classical behaviour obtained in agitated surroundings has been found again. The membrane can work thanks to the “activation" by the solute of the carrier at one interface and to the “deactivation" at the other interface, both of these mechanisms of the active transport creating a real “ionic pumping". Une pompe ionique est mise au point grâce à une ensemble “extraction-réextraction" “liquide-liquide" où le compartiment extraction et le compartiment réextraction sont mis en contact par l'intermédiaire d'une membrane contenant un transporteur dilué dans le kérosène. Ce procédé est appliqué aux ions uranyles. Des rendements intéressants sont obtenus pour des solutions diluées (100 ppm). L'étude des variables a permis de déterminer des paramètres chimiques donnant des rendements d'extraction et de réextration optimum. Le comportement symétrique des deux compartiments montre que nous avons un transport, contre-transport, couplage positif. Une modélisation chimique a permis d'identifier les mécanismes d'extraction. Le comportement classique obtenu en milieu agité est retrouvé. La pompe peut fonctionner grâce à l'activation du transporteur par le cosoluté contenu dans le compartiment d'extraction et à la désactivation à la sortie de la membrane par le cosoluté contenu dans le compartiment r

  16. Dynamics of the ion-ion acoustic instability in the thermalization of ion beams

    SciTech Connect

    Han, J.H.; Horton, W. . Inst. for Fusion Studies); Leboeuf, J.N. )

    1992-07-01

    Particle simulation using a nonlinear adiabatic electron response with two streaming ion species and nonlinear theory are used to study the collisionless thermalization of ion beams in a hot electron plasma. The slow beam or subsonic regime is investigated and the criterion for the transition from predominantly light ion to predominantly heavy ion heating is developed. Long-lived ion hole structures a-re observed in the final state.

  17. Negative ion source

    DOEpatents

    Leung, K.N.; Ehlers, K.W.

    1982-08-06

    An ionization vessel is divided into an ionizing zone and an extraction zone by a magnetic filter. The magnetic filter prevents high-energy electrons from crossing from the ionizing zone to the extraction zone. A small positive voltage impressed on a plasma grid, located adjacent an extraction grid, positively biases the plasma in the extraction zone to thereby prevent positive ions from migrating from the ionizing zone to the extraction zone. Low-energy electrons, which would ordinarily be dragged by the positive ions into the extraction zone, are thereby prevented from being present in the extraction zone and being extracted along with negative ions by the extraction grid. Additional electrons are suppressed from the output flux using ExB drift provided by permanent magnets and the extractor grid electrical field.

  18. Negative ion source

    DOEpatents

    Leung, Ka-Ngo; Ehlers, Kenneth W.

    1984-01-01

    An ionization vessel is divided into an ionizing zone and an extraction zone by a magnetic filter. The magnetic filter prevents high-energy electrons from crossing from the ionizing zone to the extraction zone. A small positive voltage impressed on a plasma grid, located adjacent an extraction grid, positively biases the plasma in the extraction zone to thereby prevent positive ions from migrating from the ionizing zone to the extraction zone. Low-energy electrons, which would ordinarily be dragged by the positive ions into the extraction zone, are thereby prevented from being present in the extraction zone and being extracted along with negative ions by the extraction grid. Additional electrons are suppressed from the output flux using ExB drift provided by permanent magnets and the extractor grid electrical field.

  19. Negative ion source

    DOEpatents

    Leung, K.N.; Ehlers, K.W.

    1984-12-04

    An ionization vessel is divided into an ionizing zone and an extraction zone by a magnetic filter. The magnetic filter prevents high-energy electrons from crossing from the ionizing zone to the extraction zone. A small positive voltage impressed on a plasma grid, located adjacent an extraction grid, positively biases the plasma in the extraction zone to thereby prevent positive ions from migrating from the ionizing zone to the extraction zone. Low-energy electrons, which would ordinarily be dragged by the positive ions into the extraction zone, are thereby prevented from being present in the extraction zone and being extracted along with negative ions by the extraction grid. Additional electrons are suppressed from the output flux using ExB drift provided by permanent magnets and the extractor grid electrical field. 14 figs.

  20. Microwave ion source

    SciTech Connect

    Leung, Ka-Ngo; Reijonen, Jani; Thomae, Rainer W.

    2005-07-26

    A compact microwave ion source has a permanent magnet dipole field, a microwave launcher, and an extractor parallel to the source axis. The dipole field is in the form of a ring. The microwaves are launched from the middle of the dipole ring using a coaxial waveguide. Electrons are heated using ECR in the magnetic field. The ions are extracted from the side of the source from the middle of the dipole perpendicular to the source axis. The plasma density can be increased by boosting the microwave ion source by the addition of an RF antenna. Higher charge states can be achieved by increasing the microwave frequency. A xenon source with a magnetic pinch can be used to produce intense EUV radiation.

  1. Oxygen ion conducting materials

    DOEpatents

    Vaughey, John; Krumpelt, Michael; Wang, Xiaoping; Carter, J. David

    2005-07-12

    An oxygen ion conducting ceramic oxide that has applications in industry including fuel cells, oxygen pumps, oxygen sensors, and separation membranes. The material is based on the idea that substituting a dopant into the host perovskite lattice of (La,Sr)MnO.sub.3 that prefers a coordination number lower than 6 will induce oxygen ion vacancies to form in the lattice. Because the oxygen ion conductivity of (La,Sr)MnO.sub.3 is low over a very large temperature range, the material exhibits a high overpotential when used. The inclusion of oxygen vacancies into the lattice by doping the material has been found to maintain the desirable properties of (La,Sr)MnO.sub.3, while significantly decreasing the experimentally observed overpotential.

  2. Oxygen ion conducting materials

    DOEpatents

    Carter, J. David; Wang, Xiaoping; Vaughey, John; Krumpelt, Michael

    2004-11-23

    An oxygen ion conducting ceramic oxide that has applications in industry including fuel cells, oxygen pumps, oxygen sensors, and separation membranes. The material is based on the idea that substituting a dopant into the host perovskite lattice of (La,Sr)MnO.sub.3 that prefers a coordination number lower than 6 will induce oxygen ion vacancies to form in the lattice. Because the oxygen ion conductivity of (La,Sr)MnO.sub.3 is low over a very large temperature range, the material exhibits a high overpotential when used. The inclusion of oxygen vacancies into the lattice by doping the material has been found to maintain the desirable properties of (La,Sr)MnO.sub.3, while significantly decreasing the experimentally observed overpotential.

  3. Radioactive ion detector

    DOEpatents

    Bower, K.E.; Weeks, D.R.

    1997-08-12

    Apparatus for detecting the presence, in aqueous media, of substances which emit alpha and/or beta radiation and determining the oxidation state of these radioactive substances, that is, whether they are in cationic or anionic form. In one embodiment, a sensor assembly has two elements, one comprised of an ion-exchange material which binds cations and the other comprised of an ion-exchange material which binds anions. Each ion-exchange element is further comprised of a scintillation plastic and a photocurrent generator. When a radioactive substance to which the sensor is exposed binds to either element and emits alpha or beta particles, photons produced in the scintillation plastic illuminate the photocurrent generator of that element. Sensing apparatus senses generator output and thereby indicates whether cationic species or anionic species or both are present and also provides an indication of species quantity. 2 figs.

  4. Radioactive ion detector

    DOEpatents

    Bower, Kenneth E.; Weeks, Donald R.

    1997-01-01

    Apparatus for detecting the presence, in aqueous media, of substances which emit alpha and/or beta radiation and determining the oxidation state of these radioactive substances, that is, whether they are in cationic or anionic form. In one embodiment, a sensor assembly has two elements, one comprised of an ion-exchange material which binds cations and the other comprised of an ion-exchange material which binds anions. Each ion-exchange element is further comprised of a scintillation plastic and a photocurrent generator. When a radioactive substance to which the sensor is exposed binds to either element and emits alpha or beta particles, photons produced in the scintillation plastic illuminate the photocurrent generator of that element. Sensing apparatus senses generator output and thereby indicates whether cationic species or anionic species or both are present and also provides an indication of species quantity.

  5. Actinide-ion sensor

    DOEpatents

    Li, Shelly X; Jue, Jan-fong; Herbst, Ronald Scott; Herrmann, Steven Douglas

    2015-01-13

    An apparatus for the real-time, in-situ monitoring of actinide-ion concentrations. A working electrolyte is positioned within the interior of a container. The working electrolyte is separated from a reference electrolyte by a separator. A working electrode is at least partially in contact with the working electrolyte. A reference electrode is at least partially in contact with the reference electrolyte. A voltmeter is electrically connected to the working electrode and the reference electrode. The working electrolyte comprises an actinide-ion of interest. The separator is ionically conductive to the actinide-ion of interest. The separator comprises an actinide, Zr, and Nb. Preferably, the actinide of the separator is Am or Np, more preferably Pu. In one embodiment, the actinide of the separator is the actinide of interest. In another embodiment, the separator further comprises P and O.

  6. ION PRODUCING MECHANISMS

    DOEpatents

    Brobeck, W.M.

    1959-02-10

    Ion generating means and means for producing ions of material for isotopic separation are discussed. One feature of the invention resides in providing a heater means located in the source block approximately equidistant from a charge reservoir and an arc chamber, whereby the heat distribution in the block is such as to avoid overheating and to maintain the temperature of the various critical localities of the unit at their optimum values. Another feature consists of a pair of plates disposed on either side of the arc chamber exit opening to define a narrow slit for the egression of the ion beam. When the adjacent edges of the plates have become worn, the plates may be detached and reversed to use the opposite edges thereof to define the exit opening.

  7. Oxygen ion conducting materials

    DOEpatents

    Vaughey, John; Krumpelt, Michael; Wang, Xiaoping; Carter, J. David

    2003-01-01

    An oxygen ion conducting ceramic oxide that has applications in industry including fuel cells, oxygen pumps, oxygen sensors, and separation membranes. The material is based on the idea that substituting a dopant into the host perovskite lattice of (La,Sr)MnO.sub.3 that prefers a coordination number lower than 6 will induce oxygen ion vacancies to form in the lattice. Because the oxygen ion conductivity of (La,Sr)MnO.sub.3 is low over a very large temperature range, the material exhibits a high overpotential when used. The inclusion of oxygen vacancies into the lattice by doping the material has been found to maintain the desirable properties of (La,Sr)MnO.sub.3, while significantly decreasing the experimentally observed overpotential.

  8. Ion channels versus ion pumps: the principal difference, in principle

    PubMed Central

    Gadsby, David C.

    2009-01-01

    Two kinds of border guards control the incessant traffic of ions across cell membranes: ion channels and ion pumps. When open, channels let selected ions diffuse rapidly down electrical and concentration gradients, whereas ion pumps labour tirelessly to maintain the gradients, by consuming energy to slowly move ions against them. Because of their diametrically opposed tasks and their divergent speeds, channels and pumps have traditionally been viewed as completely different entities, as alike as chalk and cheese. But new structural and mechanistic information about both classes of these molecular machines challenges this comfortable separation, forcing its reevaluation. PMID:19339978

  9. Laser ion source for isobaric heavy ion collider experiment.

    PubMed

    Kanesue, T; Kumaki, M; Ikeda, S; Okamura, M

    2016-02-01

    Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is (96)Ru + (96)Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions.

  10. Superfund Record of Decision (EPA Region 7): Des Moines TCE, Des Moines, Polk County, Iowa, July 1986. Final report

    SciTech Connect

    Not Available

    1986-07-21

    The Des Moines TCE site includes the underground infiltration gallery used by the Des Moines Water Works (DMWW) as a source of the public water supply. The site was discovered in 1984 after trichloroethylene (TCE) was detected in the city's public water supply. The Dico Company disposed of an unknown quantity of oily waste sludge containing TCE onto their parking lot for dust control and into a drainage ditch on their property. The primary contaminants of concern include: TCE, PCE, 1,2-dichloroethane, vinyl chloride. The selected remedial action for this site includes: extraction wells to collect the contaminated ground water; isolation of the northern-most section of the north gallery; treatment of the ground water through air stripping to remove 96% of the TCE; discharge of the treated water to the Raccoon River; operation of the west extraction wells until established effluent levels are achieved for four consecutive months.

  11. Que peut-on voir avec des neutrons? Une introduction pour des non spécialistes

    NASA Astrophysics Data System (ADS)

    Schweizer, J.

    2005-11-01

    Le neutron est une particule élémentaire qui a été découverte en 1932 par James Chadwick. Ses caractéristiques principales sont résumées dans le tableau I. Il a été utilisé pour la première fois par Clifford Shull en 1946 comme outil pour des expériences de diffusion. Cette technique s'est depuis constamment développée pour concerner tous les aspects de la matière condensée: physique, chimie, matériaux, biologie. Il s'agit d'un outil tout à fait exceptionnel car le neutron possède des propriétés uniques et particulièrement adaptées pour ces études.

  12. Ion Engine Test Firing

    NASA Technical Reports Server (NTRS)

    1999-01-01

    This image of a xenon ion engine, photographed through a port of the vacuum chamber where it was being tested at NASA's Jet Propulsion Laboratory, shows the faint blue glow of charged atoms being emitted from the engine. The ion propulsion engine is the first non-chemical propulsion to be used as the primary means of propelling a spacecraft. The first flight in NASA's New Millennium Program, Deep Space 1 is designed to validate 12 new technologies for scientific space missions of the next century. Ion propulsion was first proposed in the 1950s and NASA performed experiments on this highly efficient propulsion system in the 1960s, but it was not used aboard an American spacecraft until the 1990s. Deep Space 1 was launched in October 1998 as part of NASA's New Millennium Program, which is managed by JPL for NASA's Office of Space Science, Washington, DC. The California Institute of Technology in Pasadena manages JPL for NASA. The almost imperceptible thrust from the ion propulsion system is equivalent to the pressure exerted by a sheet of paper held in the palm of your hand. The ion engine is very slow to pick up speed, but over the long haul it can deliver 10 times as much thrust per pound of fuel as more traditional rockets. Unlike the fireworks of most chemical rockets using solid or liquid fuels, the ion drive emits only an eerie blue glow as ionized (electrically charged) atoms of xenon are pushed out of the engine. Xenon is the same gas found in photo flash tubes and many lighthouse bulbs.

  13. Tumortherapy with ion beams

    NASA Astrophysics Data System (ADS)

    Kraft, G.; Heary Ion Therapy Collaboration

    2000-11-01

    Beams of heavy-charged particles like protons or carbon ions represent the optimum tool for the treatment of deep-seated inoperable tumors: in contrast to the conventionally used photons the dose increases along with the penetration depth through the body, culminating in a sharp maximum at the end of the particle range. In order to achieve a precisely conform irradiation of the selected target volume, this maximum can be shifted in depth by energy variation and distributed laterally through magnetic deflection of the particle beam. Because carbon ions have a lateral scattering of only about 1 mm at 10 cm depth they offer the most conform irradiation. In addition to this excellent physical selectivity the biological efficiency concerning cell killing increases towards the end of the carbon ions' range. Therefore, the increase in dose is potentiated by an increase in biological efficiency. Finally, the stopping of the carbon ions can be monitored by tracing a small amount of β + active 10C and 11C ions which are produced in nuclear reactions with atoms of the penetrated tissue. This β + distribution can be visualized by applying PET-techniques, thus allowing a good control of the beam distribution. At GSI Darmstadt a heavy-ion therapy unit has been designed and constructed in collaboration with the Radiological Clinic and the DKFZ Heidelberg and the FZR Dresden. The layout of this facility as well as the treatment of now more than 30 patients will be reported on. The proposal for the layout of a dedicated medical facility at Heidelberg will be presented

  14. Ion beam sputter etching

    NASA Technical Reports Server (NTRS)

    Banks, Bruce A.; Rutledge, Sharon K.

    1986-01-01

    An ion beam etching process which forms extremely high aspect ratio surface microstructures using thin sputter masks is utilized in the fabrication of integrated circuits. A carbon rich sputter mask together with unmasked portions of a substrate is bombarded with inert gas ions while simultaneous carbon deposition occurs. The arrival of the carbon deposit is adjusted to enable the sputter mask to have a near zero or even slightly positive increase in thickness with time while the unmasked portions have a high net sputter etch rate.

  15. Heavy ion collisions

    SciTech Connect

    Jacak, B.V.

    1994-11-01

    Heavy ion collisions at very high energies provide an opportunity to recreate in the laboratory the conditions which existed very early in the universe, just after the big bang. We prepare matter at very high energy density and search for evidence that the quarks and gluons are deconfined. I describe the kinds of observables that are experimentally accessible to characterize the system and to search for evidence of new physics. A wealth of information is now available from CERN and BNL heavy ion experiments. I discuss recent results on two particle correlations, strangeness production, and dilepton and direct photon distributions.

  16. CALUTRON ION SOURCE

    DOEpatents

    Lofgren, E.J.

    1959-02-17

    An improvement is described in ion source mechanisms whereby the source structure is better adapted to withstanid the ravages of heat, erosion, and deterioration concomitant with operation of an ion source of the calutron type. A pair of molybdenum plates define the exit opening of the arc chamber and are in thermal contact with the walls of the chamber. These plates are maintained at a reduced temperature by a pair of copper blocks in thermal conducting contact therewith to form subsequent diverging margins for the exit opening.

  17. Hydrogen ion microlithography

    DOEpatents

    Tsuo, Y. Simon; Deb, Satyen K.

    1990-01-01

    Disclosed is a hydrogen ion microlithography process for use in microelectronic fabrication and semiconductor device processing. The process comprises the steps of providing a single layer of either an amorphous silicon or hydrogenated amorphous silicon material. A pattern is recorded in a selected layer of amorphous silicon or hydrogenated amorphous silicon materials by preferentially implanting hydrogen ions therein so as to permit the selected layer to serve as a mask-resist wafer suitable for subsequent development and device fabrication. The layer is developed to provide a surface pattern therein adaptable for subsequent use in microelectronic fabrication and semiconductor device processing.

  18. Hydrogen ion microlithography

    DOEpatents

    Tsuo, Y.S.; Deb, S.K.

    1990-10-02

    Disclosed is a hydrogen ion microlithography process for use in microelectronic fabrication and semiconductor device processing. The process comprises the steps of providing a single layer of either an amorphous silicon or hydrogenated amorphous silicon material. A pattern is recorded in a selected layer of amorphous silicon or hydrogenated amorphous silicon materials by preferentially implanting hydrogen ions therein so as to permit the selected layer to serve as a mask-resist wafer suitable for subsequent development and device fabrication. The layer is developed to provide a surface pattern therein adaptable for subsequent use in microelectronic fabrication and semiconductor device processing. 6 figs.

  19. Asymmetric ion trap

    DOEpatents

    Barlow, Stephan E.; Alexander, Michael L.; Follansbee, James C.

    1997-01-01

    An ion trap having two end cap electrodes disposed asymmetrically about a center of a ring electrode. The inner surface of the end cap electrodes are conformed to an asymmetric pair of equipotential lines of the harmonic formed by the application of voltages to the electrodes. The asymmetry of the end cap electrodes allows ejection of charged species through the closer of the two electrodes which in turn allows for simultaneously detecting anions and cations expelled from the ion trap through the use of two detectors charged with opposite polarity.

  20. ION PRODUCING MECHANISM

    DOEpatents

    Backus, J.G.

    1958-09-01

    This patent relates to improvements in calutron devices and particularly describes a novel ion source. The unique feature of this source lies in the shaping of the ionizing electron stream to conform to the arc plasma boundary at the exit slit of the ionization chamber, thereby increasing the ion density produced at the plasma boundary. The particular structure consists of an electron source disposed at onc end of an elongated ionization chambcr and a coilimating electrode positioned to trim the electron stream to a crescent shape before entering the ionization chamber.

  1. Uranyl ion coordination

    USGS Publications Warehouse

    Evans, H.T.

    1963-01-01

    A review of the known crystal structures containing the uranyl ion shows that plane-pentagon coordination is equally as prevalent as plane-square or plane-hexagon. It is suggested that puckered-hexagon configurations of OH - or H2O about the uranyl group will tend to revert to plane-pentagon coordination. The concept of pentagonal coordination is invoked for possible explanations of the complex crystallography of the natural uranyl hydroxides and the unusual behavior of polynuclear ions in hydrolyzed uranyl solutions.

  2. Interferometry with Strontium Ions

    NASA Astrophysics Data System (ADS)

    Jackson, Jarom; Lambert, Enoch; Otterstrom, Nils; Jones, Tyler; Durfee, Dallin

    2014-05-01

    We describe progress on a cold ion matter-wave interferometer. Cold Strontium atoms are extracted from an LVIS. The atoms will be photo-ionized with a two-photon transition to an auto-ionizing state in the continuum. The ions will be split and recombined using stimulated Raman transitions from a pair of diode lasers injection locked to two beams from a master laser which have been shifted up and down by half the hyperfine splitting. We are developing laser instrumentation for this project including a method to prevent mode-hopping by analyzing laser frequency noise, and an inexpensive, robust wavelength meter. Supported by NSF Award No. 1205736.

  3. Asymmetric ion trap

    DOEpatents

    Barlow, S.E.; Alexander, M.L.; Follansbee, J.C.

    1997-12-02

    An ion trap having two end cap electrodes disposed asymmetrically about a center of a ring electrode is disclosed. The inner surface of the end cap electrodes are conformed to an asymmetric pair of equipotential lines of the harmonic formed by the application of voltages to the electrodes. The asymmetry of the end cap electrodes allows ejection of charged species through the closer of the two electrodes which in turn allows for simultaneously detecting anions and cations expelled from the ion trap through the use of two detectors charged with opposite polarity. 4 figs.

  4. Lithium Ion Batteries

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Lithium ion batteries, which use a new battery chemistry, are being developed under cooperative agreements between Lockheed Martin, Ultralife Battery, and the NASA Lewis Research Center. The unit cells are made in flat (prismatic) shapes that can be connected in series and parallel to achieve desired voltages and capacities. These batteries will soon be marketed to commercial original-equipment manufacturers and thereafter will be available for military and space use. Current NiCd batteries offer about 35 W-hr/kg compared with 110 W-hr/kg for current lithium ion batteries. Our ultimate target for these batteries is 200 W-hr/kg.

  5. Etudes physiques des mélanges eau-cryoprotecteurs

    NASA Astrophysics Data System (ADS)

    Vassoille, R.; Perez, J.

    The aim of the following review is to present the most important studies concerning the physical properties of water-solutes mixtures used in cryobiology. Cryobiology is a branch of biology which deals with the very low temperature behaviour of cells. This technique is developed today in several directions. The creation of banks of cells and perhaps in a short time of small organs, is the purpose of much research in this domain. Before freezing, living cells are generally put in a solution containing one or more solutes. The role of these solutes is to protect the cells against damage due to crystallization of water (cryoprotectors). The mechanisms of cryoprotection are not well known ; nevertheless the vitreous state formation during cooling is often invoked. So, it is possible to avoid crystallization damage such as mechanical strain (due to an increase of volume of about 10 %) and salt effects (due to osmotic pressure). The conditions in which the vitreous state is obtained, maintained during cooling, storage at low temperature and rewarming can be defined by physical studies presented in the following review. Le présent travail est essentiellement une revue bibliographique des principales études physiques qui ont été réalisées avec des solutions de composés habituellement employés en cryobiologie. La cryobiologie est une branche de la biologie qui s'intéresse au comportement des cellules à basse température. Cette discipline est actuellement en plein développement dans des domaines très divers. Son principal but est la création de banques de cellules de plus en plus complexes avec comme perspective la conservation des organes. Les cellules vivantes sont généralement placées avant congélation dans une solution contenant divers composés dont le rôle est de protéger les cellules contre les effets de la cristallisation de l'eau. L'action protectrice de ces cryoprotecteurs est encore mal connue; cependant, la formation d'un état vitreux lors du

  6. Nonpropulsive applications of ion beams

    NASA Technical Reports Server (NTRS)

    Hudson, W. R.

    1976-01-01

    Eight centimeter ion beam sources utilizing xenon and argon have been developed that operate over a wide range of beam energies and currents. Three types of processes have been studied: sputter deposition, ion beam machining, and ion beam surface texturing. The broad range of source operating conditions allows optimum sputter deposition of various materials. An ion beam source was used to ion mill laser reflection holograms using photoresist patterns on silicon. Ion beam texturing was tried with many materials and has a multitude of potential applications.

  7. Superfund Record of Decision (EPA Region 7): Des Moines TCE Site, Operable Unit 3, Des Moines, IA. (Second remedial action), September 1992. Final report

    SciTech Connect

    Not Available

    1992-09-18

    The Des Moines TCE site is located southwest of downtown Des Moines, Polk County, Iowa. Land use in the area is predominantly industrial and commercial, and part of the site lies within the floodplain of the Raccoon River. Water from the Des Moines Water Works north infiltration gallery was found to be contaminated with trichloroethylene (TCE), dichloroethylene (DCE), and vinyl chloride at levels above accepted drinking water standards. The ROD addresses OU3, which encompasses potential sources of ground water contamination in an area north of the Raccoon River. The selected remedial action for OU3 includes no action with periodic groundwater monitoring.

  8. Profil épidemio-clinique et radiologique des atteintes ostéo-articulaires des hémophiles à Madagascar

    PubMed Central

    Narindra, Lova Hasina Rajaonarison Ny Ony; Rabemanorintsoa, Feno Hasina; Randrianantenaina, Faralahy Ravelonarivo; Rakoto, Olivat Alson Aimée; Ahmad, Ahmad

    2014-01-01

    Introduction Déterminer le profil épidémio-clinique et radiologique des atteintes ostéo-articulaires des hémophiles malagasy. Méthodes Une étude prospective, descriptive portant sur 25 patients hémophiles venant de tout Madagascar a été réalisée. Des radiographies numérisées des genoux, des chevilles et des coudes en incidence de face et de profil ainsi qu'une échographie des hanches, des genoux, des chevilles et des coudes ont été réalisées chez ces patients. Le type et la sévérité de la maladie ainsi que l'aspect de la cavité articulaire, la synoviale, les noyaux épiphysaires et les surfaces articulaires ont été analysés. Résultats Soixante-huit pourcent des patients étaient hémophiles de type A et 32 % de type B. Quarante pourcent étaient classés sévères, 28 % modérés et 32 % mineurs. Les atteintes ostéo-articulaires ont été retrouvées chez 56 % des patients. Il n'existait pas de prédominance d'atteinte selon le type ni la sévérité de la maladie. Les plus jeunes étaient les plus atteints et l'articulation du genou et de la cheville étaient les plus touchées. Conclusion Les complications ostéo-articulaire de l'hémophilie sont graves et ne dépendent pas du type ni de la sévérité de l'affection. Elles touchent surtout les enfants d'âge scolaire. Le couple radiographie-échographie permet de diagnostiquer et de surveiller ces lésions. PMID:25870742

  9. Ion-ion dynamic structure factor of warm dense mixtures

    SciTech Connect

    Gill, N. M.; Heinonen, R. A.; Starrett, C. E.; Saumon, D.

    2015-06-25

    In this study, the ion-ion dynamic structure factor of warm dense matter is determined using the recently developed pseudoatom molecular dynamics method [Starrett et al., Phys. Rev. E 91, 013104 (2015)]. The method uses density functional theory to determine ion-ion pair interaction potentials that have no free parameters. These potentials are used in classical molecular dynamics simulations. This constitutes a computationally efficient and realistic model of dense plasmas. Comparison with recently published simulations of the ion-ion dynamic structure factor and sound speed of warm dense aluminum finds good to reasonable agreement. Using this method, we make predictions of the ion-ion dynamical structure factor and sound speed of a warm dense mixture—equimolar carbon-hydrogen. This material is commonly used as an ablator in inertial confinement fusion capsules, and our results are amenable to direct experimental measurement.

  10. Ion-dust streaming instability with non-Maxwellian ions

    SciTech Connect

    Kählert, Hanno

    2015-07-15

    The influence of non-Maxwellian ions on the ion-dust streaming instability in a complex plasma is investigated. The ion susceptibility employed for the calculations self-consistently accounts for the acceleration of the ions by a homogeneous background electric field and their collisions with neutral gas particles via a Bhatnagar-Gross-Krook collision term [e.g., A. V. Ivlev et al., Phys. Rev. E 71, 016405 (2005)], leading to significant deviations from a shifted Maxwellian distribution. The dispersion relation and the properties of the most unstable mode are studied in detail and compared with the Maxwellian case. The largest deviations occur at low to intermediate ion-neutral damping. In particular, the growth rate of the instability for ion streaming below the Bohm speed is found to be lower than in the case of Maxwellian ions, yet remains on a significant level even for fast ion flows above the Bohm speed.

  11. Molecular ion sources for low energy semiconductor ion implantation (invited)

    NASA Astrophysics Data System (ADS)

    Hershcovitch, A.; Gushenets, V. I.; Seleznev, D. N.; Bugaev, A. S.; Dugin, S.; Oks, E. M.; Kulevoy, T. V.; Alexeyenko, O.; Kozlov, A.; Kropachev, G. N.; Kuibeda, R. P.; Minaev, S.; Vizir, A.; Yushkov, G. Yu.

    2016-02-01

    Smaller semiconductors require shallow, low energy ion implantation, resulting space charge effects, which reduced beam currents and production rates. To increase production rates, molecular ions are used. Boron and phosphorous (or arsenic) implantation is needed for P-type and N-type semiconductors, respectively. Carborane, which is the most stable molecular boron ion leaves unacceptable carbon residue on extraction grids. A self-cleaning carborane acid compound (C4H12B10O4) was synthesized and utilized in the ITEP Bernas ion source resulting in large carborane ion output, without carbon residue. Pure gaseous processes are desired to enable rapid switch among ion species. Molecular phosphorous was generated by introducing phosphine in dissociators via 4PH3 = P4 + 6H2; generated molecular phosphorous in a pure gaseous process was then injected into the HCEI Calutron-Bernas ion source, from which P4+ ion beams were extracted. Results from devices and some additional concepts are described.

  12. Molecular ion sources for low energy semiconductor ion implantation (invited).

    PubMed

    Hershcovitch, A; Gushenets, V I; Seleznev, D N; Bugaev, A S; Dugin, S; Oks, E M; Kulevoy, T V; Alexeyenko, O; Kozlov, A; Kropachev, G N; Kuibeda, R P; Minaev, S; Vizir, A; Yushkov, G Yu

    2016-02-01

    Smaller semiconductors require shallow, low energy ion implantation, resulting space charge effects, which reduced beam currents and production rates. To increase production rates, molecular ions are used. Boron and phosphorous (or arsenic) implantation is needed for P-type and N-type semiconductors, respectively. Carborane, which is the most stable molecular boron ion leaves unacceptable carbon residue on extraction grids. A self-cleaning carborane acid compound (C4H12B10O4) was synthesized and utilized in the ITEP Bernas ion source resulting in large carborane ion output, without carbon residue. Pure gaseous processes are desired to enable rapid switch among ion species. Molecular phosphorous was generated by introducing phosphine in dissociators via 4PH3 = P4 + 6H2; generated molecular phosphorous in a pure gaseous process was then injected into the HCEI Calutron-Bernas ion source, from which P4(+) ion beams were extracted. Results from devices and some additional concepts are described.

  13. Electron-less negative ion extraction from ion-ion plasmas

    SciTech Connect

    Rafalskyi, Dmytro; Aanesland, Ane

    2015-03-09

    This paper presents experimental results showing that continuous negative ion extraction, without co-extracted electrons, is possible from highly electronegative SF{sub 6} ion-ion plasma at low gas pressure (1 mTorr). The ratio between the negative ion and electron densities is more than 3000 in the vicinity of the two-grid extraction and acceleration system. The measurements are conducted by both magnetized and non-magnetized energy analyzers attached to the external grid. With these two analyzers, we show that the extracted negative ion flux is almost electron-free and has the same magnitude as the positive ion flux extracted and accelerated when the grids are biased oppositely. The results presented here can be used for validation of numerical and analytical models of ion extraction from ion-ion plasma.

  14. Photo ion spectrometer

    DOEpatents

    Gruen, D.M.; Young, C.E.; Pellin, M.J.

    1989-08-08

    A method and apparatus are described for extracting for quantitative analysis ions of selected atomic components of a sample. A lens system is configured to provide a slowly diminishing field region for a volume containing the selected atomic components, enabling accurate energy analysis of ions generated in the slowly diminishing field region. The lens system also enables focusing on a sample of a charged particle beam, such as an ion beam, along a path length perpendicular to the sample and extraction of the charged particles along a path length also perpendicular to the sample. Improvement of signal to noise ratio is achieved by laser excitation of ions to selected auto-ionization states before carrying out quantitative analysis. Accurate energy analysis of energetic charged particles is assured by using a preselected resistive thick film configuration disposed on an insulator substrate for generating predetermined electric field boundary conditions to achieve for analysis the required electric field potential. The spectrometer also is applicable in the fields of SIMS, ISS and electron spectroscopy. 8 figs.

  15. Pulsed ion beam source

    DOEpatents

    Greenly, J.B.

    1997-08-12

    An improved pulsed ion beam source is disclosed having a new biasing circuit for the fast magnetic field. This circuit provides for an initial negative bias for the field created by the fast coils in the ion beam source which pre-ionize the gas in the source, ionize the gas and deliver the gas to the proper position in the accelerating gap between the anode and cathode assemblies in the ion beam source. The initial negative bias improves the interaction between the location of the nulls in the composite magnetic field in the ion beam source and the position of the gas for pre-ionization and ionization into the plasma as well as final positioning of the plasma in the accelerating gap. Improvements to the construction of the flux excluders in the anode assembly are also accomplished by fabricating them as layered structures with a high melting point, low conductivity material on the outsides with a high conductivity material in the center. 12 figs.

  16. Lithium ion conducting electrolytes

    DOEpatents

    Angell, Charles Austen; Liu, Changle; Xu, Kang; Skotheim, Terje A.

    1999-01-01

    The present invention relates generally to highly conductive alkali-metal ion non-crystalline electrolyte systems, and more particularly to novel and unique molten (liquid), rubbery, and solid electrolyte systems which are especially well suited for use with high current density electrolytic cells such as primary and secondary batteries.

  17. Advanced ion thruster research

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1984-01-01

    A simple model describing the discharge chamber performance of high strength, cusped magnetic field ion thrusters is developed. The model is formulated in terms of the energy cost of producing ions in the discharge chamber and the fraction of ions produced in the discharge chamber that are extracted to form the ion beam. The accuracy of the model is verified experimentally in a series of tests wherein the discharge voltage, propellant, grid transparency to neutral atoms, beam diameter and discharge chamber wall temperature are varied. The model is exercised to demonstrate what variations in performance might be expected by varying discharge chamber parameters. The results of a study of xenon and argon orificed hollow cathodes are reported. These results suggest that a hollow cathode model developed from research conducted on mercury cathodes can also be applied to xenon and argon. Primary electron mean free paths observed in argon and xenon cathodes that are larger than those found in mercury cathodes are identified as a cause of performance differences between mercury and inert gas cathodes. Data required as inputs to the inert gas cathode model are presented so it can be used as an aid in cathode design.

  18. Ion implantation in polymers

    NASA Astrophysics Data System (ADS)

    Wintersgill, M. C.

    1984-02-01

    An introductory overview will be given of the effects of ion implantation on polymers, and certain areas will be examined in more detail. Radiation effects in general and ion implantation in particular, in the field of polymers, present a number of contrasts with those in ionic crystals, the most obvious difference being that the chemical effects of both the implanted species and the energy transfer to the host may profoundly change the nature of the target material. Common effects include crosslinking and scission of polymer chains, gas evolution, double bond formation and the formation of additional free radicals. Research has spanned the chemical processes involved, including polymerization reactions achievable only with the use of radiation, to applied research dealing both with the effects of radiation on polymers already in commercial use and the tailoring of new materials to specific applications. Polymers are commonly divided into two groups, in describing their behavior under irradiation. Group I includes materials which form crosslinks between molecules, whereas Group II materials tend to degrade. In basic research, interest has centered on Group I materials and of these polyethylene has been studied most intensively. Applied materials research has investigated a variety of polymers, particularly those used in cable insulation, and those utilized in ion beam lithography of etch masks. Currently there is also great interest in enhancing the conducting properties of polymers, and these uses would tend to involve the doping capabilities of ion implantation, rather than the energy deposition.

  19. Industrial ion source technology

    NASA Technical Reports Server (NTRS)

    Kaufman, H. R.; Robinson, R. S.

    1978-01-01

    An analytical model was developed to describe the development of a coned surface texture with ion bombardment and simultaneous deposition of an impurity. A mathematical model of sputter deposition rate from a beveled target was developed in conjuction with the texturing models to provide an important input to that model. The establishment of a general procedure that will allow the treatment of manay different sputtering configurations is outlined. Calculation of cross sections for energetic binary collisions was extened to Ar, Kr.. and Xe with total cross sections for viscosity and diffusion calculated for the interaction energy range from leV to 1000eV. Physical sputtering and reactive ion etching experiments provided experimental data on the operating limits of a broad beam ion source using CF4 as a working gas to produce reactive species in a sputtering beam. Magnetic clustering effects are observed when Al is seeded with Fe and sputtered with Ar(?) ions. Silicon was textured at a micron scale by using a substrate temperature of 600 C.

  20. Laser driven ion accelerator

    DOEpatents

    Tajima, Toshiki

    2006-04-18

    A system and method of accelerating ions in an accelerator to optimize the energy produced by a light source. Several parameters may be controlled in constructing a target used in the accelerator system to adjust performance of the accelerator system. These parameters include the material, thickness, geometry and surface of the target.

  1. Photo ion spectrometer

    DOEpatents

    Gruen, Dieter M.; Young, Charles E.; Pellin, Michael J.

    1989-01-01

    A method and apparatus for extracting for quantitative analysis ions of selected atomic components of a sample. A lens system is configured to provide a slowly diminishing field region for a volume containing the selected atomic components, enabling accurate energy analysis of ions generated in the slowly diminishing field region. The lens system also enables focusing on a sample of a charged particle beam, such as an ion beam, along a path length perpendicular to the sample and extraction of the charged particles along a path length also perpendicular to the sample. Improvement of signal to noise ratio is achieved by laser excitation of ions to selected autoionization states before carrying out quantitative analysis. Accurate energy analysis of energetic charged particles is assured by using a preselected resistive thick film configuration disposed on an insulator substrate for generating predetermined electric field boundary conditions to achieve for analysis the required electric field potential. The spectrometer also is applicable in the fields of SIMS, ISS and electron spectroscopy.

  2. ION PRODUCING MECHANISM

    DOEpatents

    Oppenheimer, F.F.

    1959-06-01

    A calutron ion source is described which masks the ends of the arc to provide a more stable beam from the middle portion. The masking is effected by milling the arc slit in a single sheet of material which is secured to the open face of the arc block. (T.R.H.)

  3. Ion Beam Simulator

    2005-11-08

    IBSimu(Ion Beam Simulator) is a computer program for making two and three dimensional ion optical simulations. The program can solve electrostatic field in a rectangular mesh using Poisson equation using Finite Difference method (FDM). The mesh can consist of a coarse and a fine part so that the calculation accuracy can be increased in critical areas of the geometry, while most of the calculation is done quickly using the coarse mesh. IBSimu can launch ionmore » beam trajectories into the simulation from an injection surface or fomo plasma. Ion beam space charge of time independent simulations can be taken in account using Viasov iteration. Plasma is calculated by compensating space charge with electrons having Boltzmann energy distribution. The simulation software can also be used to calculate time dependent cases if the space charge is not calculated. Software includes diagnostic tools for plotting the geometry, electric field, space charge map, ion beam trajectories, emittance data and beam profiles.« less

  4. Compact RF ion source for industrial electrostatic ion accelerator

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeok-Jung; Park, Sae-Hoon; Kim, Dae-Il; Cho, Yong-Sub

    2016-02-01

    Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

  5. Compact RF ion source for industrial electrostatic ion accelerator.

    PubMed

    Kwon, Hyeok-Jung; Park, Sae-Hoon; Kim, Dae-Il; Cho, Yong-Sub

    2016-02-01

    Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

  6. Ion polarization in the MEIC figure-8 ion collider ring

    SciTech Connect

    V.S. Morozov, Ya.S. Derbenev, Y. Zhang, P. Chevtsov, A.M. Kondratenko, M.A. Kondratenko, Yu.N. Filatov

    2012-07-01

    The nuclear physics program envisaged at the Medium-energy Electron-Ion Collider (MEIC) currently being developed at the Jefferson Lab calls for collisions of 3-11 GeV/c longitudinally polarized electrons and 20-100 GeV/c, in equivalent proton momentum, longitudinally/ transversely polarized protons/ deuterons/ light ions. We present a scheme that provides the required ion polarization arrangement in the MEIC's ion collider ring.

  7. Bioinspired artificial single ion pump.

    PubMed

    Zhang, Huacheng; Hou, Xu; Zeng, Lu; Yang, Fu; Li, Lin; Yan, Dadong; Tian, Ye; Jiang, Lei

    2013-10-30

    Bioinspired artificial functional nanochannels for intelligent molecular and ionic transport control at the nanoscale have wide potential applications in nanofluidics, energy conversion, and biosensors. Although various smart passive ion transport properties of ion channels have been artificially realized, it is still hugely challenging to achieve high level intelligent ion transport features in biological ion pumps. Here we show a unique bioinspired single ion pump based on a cooperative pH response double-gate nanochannel, whose gates could be opened and closed alternately/simultaneously under symmetric/asymmetric pH environments. With the stimulation of the double-gate nanochannel by continuous switching of the symmetric/asymmetric pH stimuli, the bioinspired system systematically realized three key ionic transport features of biological ion pumps, including an alternating gates ion pumping process under symmetric pH stimuli, transformation of the ion pump into an ion channel under asymmetric pH stimuli, and a fail-safe ion pumping feature under both symmetric and asymmetric pH stimuli. The ion pumping processes could well be reproduced under a concentration gradient. With the advantages of the extraordinary ionic transport functions of biological ion pumps, the bioinspired ion pump should find widespread applicability in active transportation-controlling smart nanofluidic devices, efficient energy conversions, and seawater desalinization, and open the way to design and develop novel bioinspired intelligent artificial nanochannel materials.

  8. Bioinspired artificial single ion pump.

    PubMed

    Zhang, Huacheng; Hou, Xu; Zeng, Lu; Yang, Fu; Li, Lin; Yan, Dadong; Tian, Ye; Jiang, Lei

    2013-10-30

    Bioinspired artificial functional nanochannels for intelligent molecular and ionic transport control at the nanoscale have wide potential applications in nanofluidics, energy conversion, and biosensors. Although various smart passive ion transport properties of ion channels have been artificially realized, it is still hugely challenging to achieve high level intelligent ion transport features in biological ion pumps. Here we show a unique bioinspired single ion pump based on a cooperative pH response double-gate nanochannel, whose gates could be opened and closed alternately/simultaneously under symmetric/asymmetric pH environments. With the stimulation of the double-gate nanochannel by continuous switching of the symmetric/asymmetric pH stimuli, the bioinspired system systematically realized three key ionic transport features of biological ion pumps, including an alternating gates ion pumping process under symmetric pH stimuli, transformation of the ion pump into an ion channel under asymmetric pH stimuli, and a fail-safe ion pumping feature under both symmetric and asymmetric pH stimuli. The ion pumping processes could well be reproduced under a concentration gradient. With the advantages of the extraordinary ionic transport functions of biological ion pumps, the bioinspired ion pump should find widespread applicability in active transportation-controlling smart nanofluidic devices, efficient energy conversions, and seawater desalinization, and open the way to design and develop novel bioinspired intelligent artificial nanochannel materials. PMID:23773031

  9. Composite ion exchange materials

    SciTech Connect

    Amarasinghe, S.; Zook, L.; Leddy, J.

    1994-12-31

    Composite ion exchange materials can be formed by sorbing ion exchange polymers on inert, high surface area substrates. In general, the flux of ions and molecules through these composites, as measured electrochemically, increases as the ratio of the surface area of the substrate increases relative to the volume of the ion exchanger. This suggests that fields and gradients established at the interface between the ion exchanger and substrate are important in determining the transport characteristics of the composites. Here, the authors will focus on composites formed with a cation exchange polymer, Nafion, and two different types of microbeads: polystyrene microspheres and polystyrene coated magnetic microbeads. For the polystyrene microbeads, scanning electron micrographs suggest the beads cluster in a self-similar manner, independent of the bead diameter. Flux of Ru(NH3)63+ through the composites was studied as a function of bead fraction, bead radii, and fixed surface area with mixed bead sizes. Flux was well modeled by surface diffusion along a fractal interface. Magnetic composites were formed with columns of magnetic microbeads normal to the electrode surface. Flux of Ru(NH3)63+ through these composites increased exponentially with bead fraction. For electrolyses, the difference in the molar magnetic susceptibility of the products and reactants, Dcm, tends to be non-zero. For seven redox reactions, the ratio of the flux through the magnetic composites to the flux through a Nafion film increases monotonically with {vert_bar}Dcm{vert_bar}, with enhancements as large as thirty-fold. For reversible species, the electrolysis potential through the magnetic composites is 35 mV positive of that for the Nafion films.

  10. Cholesterol and Ion Channels

    PubMed Central

    Levitan, Irena; Fang, Yun; Rosenhouse-Dantsker, Avia; Romanenko, Victor

    2010-01-01

    A variety of ion channels, including members of all major ion channel families, have been shown to be regulated by changes in the level of membrane cholesterol and partition into cholesterol-rich membrane domains. In general, several types of cholesterol effects have been described. The most common effect is suppression of channel activity by an increase in membrane cholesterol, an effect that was described for several types of inwardly-rectifying K+ channels, voltage-gated K+ channels, Ca+2 sensitive K+ channels, voltage-gated Na+ channels, N-type voltage-gated Ca+2 channels and volume-regulated anion channels. In contrast, several types of ion channels, such as epithelial amiloride-sensitive Na+ channels and Transient Receptor Potential channels, as well as some of the types of inwardly-rectifying and voltage-gated K+ channels were shown to be inhibited by cholesterol depletion. Cholesterol was also shown to alter the kinetic properties and current-voltage dependence of several voltage-gated channels. Finally, maintaining membrane cholesterol level is required for coupling ion channels to signalling cascades. In terms of the mechanisms, three general mechanisms have been proposed: (i) specific interactions between cholesterol and the channel protein, (ii) changes in the physical properties of the membrane bilayer and (iii) maintaining the scaffolds for protein-protein interactions. The goal of this review is to describe systematically the role of cholesterol in regulation of the major types of ion channels and to discuss these effects in the context of the models proposed. PMID:20213557

  11. Using Ion Exchange Chromatography to Separate and Quantify Complex Ions

    ERIC Educational Resources Information Center

    Johnson, Brian J.

    2014-01-01

    Ion exchange chromatography is an important technique in the separation of charged species, particularly in biological, inorganic, and environmental samples. In this experiment, students are supplied with a mixture of two substitution-inert complex ions. They separate the complexes by ion exchange chromatography using a "flash"…

  12. Introduction to Ion Beam Therapy

    SciTech Connect

    Martisikova, Maria

    2010-01-05

    Presently, ion beam therapy reaches an increasing interest within the field of radiation therapy, which is caused by the promising clinical results obtained in the last decades. Ion beams enable higher dose conformation to the tumor and increased sparing of the surrounding tissue in comparison to the standard therapy using high energy photons. Heavy ions, like carbon, offer in addition increased biological effectiveness, which makes them suitable for treatment of radioresistant tumors. This contribution gives an overview over the physical and biological properties of ion beams. Common fundamental principles of ion beam therapy are summarized and differences between standard therapy with high energy photons, proton and carbon ion therapy are discussed. The technologies used for the beam production and delivery are introduced, with emphasis to the differences between passive and active beam delivery systems. The last part concentrates on the quality assurance in ion therapy. Specialties of dosimetry in medical ion beams are discussed.

  13. Le contrôle des infections au cabinet du pédiatre

    PubMed Central

    2008-01-01

    RÉSUMÉ La transmission des infections au cabinet du pédiatre est de plus en plus préoccupante. Le présent document expose les voies de transmission des infections et les principes sous-jacents aux mesures actuelles pour contrôler les infections. Pour prévenir les infections, il faut bien concevoir le cabinet et adopter des politiques administratives et de triage convenables, de même que des pratiques de base pour les soins de tous les patients (p. ex., hygiène des mains, port de gants, de masques, de lunettes de protection et d’une blouse d’hôpital pour des interventions précises; nettoyage, désinfection et stérilisation convenables des surfaces et du matériel, y compris les jouets, et techniques d’asepsie en cas d’interventions effractives) et des précautions additionnelles en cas d’infections précises. Le personnel doit avoir reçu les vaccins pertinents, et les personnes infectées doivent respecter les politiques de restriction au travail.

  14. Membranes in Lithium Ion Batteries

    PubMed Central

    Yang, Min; Hou, Junbo

    2012-01-01

    Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed. PMID:24958286

  15. Ion plating for the future

    NASA Technical Reports Server (NTRS)

    Spalvins, T.

    1981-01-01

    The ion plating techniques are classified relative to the instrumental set up, evaporation media, and mode of transport. A distinction is drawn between the low vacuum (plasma) and high vacuum (ion beam) techniques. Ion plating technology is discussed at the fundamental and industrial level. At the fundamental level, the capabilities and limitations of the plasma (evaporant flux) and film characteristics are evaluated. And on the industrial level, the performance and potential uses of ion plated films are discussed.

  16. A Cold Strontium Ion Source

    NASA Astrophysics Data System (ADS)

    Erickson, Christopher J.; Lyon, Mary; Blaser, Kelvin; Harper, Stuart; Durfee, Dallin

    2010-03-01

    We present a cold ion source for strontium 87. The source is based off of a standard Low-Velocity-Intense-Source (LVIS) for strontium using permanent magnets in place of anti-Helmholtz coils. Atoms from the LVIS are then ionized in a two photon process as they pass a 20kV anode plate. The result is a mono-energetic beam of ions whose velocity is tunable. Applications for the ions include spectroscopy and ion interferometry.

  17. Lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse

    PubMed Central

    Kahan, Meldon; Mailis-Gagnon, Angela; Wilson, Lynn; Srivastava, Anita

    2011-01-01

    Résumé Objectif Présenter aux médecins de famille un résumé clinique pratique des lignes directrices canadiennes sur l’utilisation sécuritaire et efficace des opioïdes pour la douleur chronique non cancéreuse, produites par le National Opioid Use Guideline Group. Qualité des données Pour produire les lignes directrices, les chercheurs ont effectué une synthèse critique de la littérature médicale sur l’efficacité et l’innocuité des opioïdes pour la douleur chronique non cancéreuse et ont rédigé une série de recommandations. Un panel de 49 cliniciens experts de toutes les régions du Canada ont passé en revue l’ébauche et ont atteint un consensus sur 24 recommandations. Message principal Il est recommandé de faire un dépistage du risque de dépendance avant de prescrire des opioïdes. On recommande des opioïdes faibles (codéine et tramadol) pour une douleur de légère à modérée qui n’a pas répondu aux traitements de première intention. On peut essayer l’oxycodone, l’hydromorphone et la morphine chez les patients qui n’ont pas eu de soulagement avec des opioïdes plus faibles. Une faible dose initiale et une lente hausse du titrage sont recommandées, ainsi qu’une étroite surveillance du patient qu’on a d’abord renseigné. Les médecins doivent surveiller l’apparition de complications comme l’apnée du sommeil. La dose optimale est celle qui améliore le fonctionnement ou atténue les cotes d’évaluation de la douleur d’au moins 30 %. Pour la grande majorité des patients, la dose optimale sera bien en deçà de l’équivalent de 200 mg de morphine par jour. On recommande le sevrage progressif pour les patients qui n’ont pas répondu à un essai d’opioïdes adéquat. Conclusion Les opioïdes jouent un rôle important dans la prise en charge de la douleur chronique non cancéreuse, mais il faut en prescrire avec prudence pour limiter les dommages potentiels. Les nouvelles lignes directrices

  18. Comprendre la maltraitance des aînés en pratique familiale

    PubMed Central

    Yaffe, Mark J.; Tazkarji, Bachir

    2012-01-01

    Résumé Objectif Présenter ce qui constitue la maltraitance des aînés, ce dont les médecins de famille devraient être au courant, les signes et les symptômes laissant présager de mauvais traitements chez des adultes plus âgés, comment l’outil Elder Abuse Suspicion Index peut aider à détecter la maltraitance et les options qui existent pour réagir en cas de soupçons de maltraitance. Sources des données On a fait une recension dans MEDLINE, PsycINFO et Social Work Abstracts pour trouver des publications en français ou en anglais, de 1970 à 2011, à l’aide des expressions elder abuse, elder neglect, elder mistreatment, seniors, older adults, violence, identification, detection tools et signs and symptoms. Les publications pertinentes ont fait l’objet d’un examen. Message principal La maltraitance des aînés est une cause importante de morbidité et de mortalité chez les adultes plus âgés. Si les médecins de famille sont bien placés pour détecter des mauvais traitements infligés aux aînés, leurs taux réels de signalement de cas de maltraitance sont plus faibles que dans d’autres professions. Cette situation pourrait s’améliorer s’ils comprenaient mieux les genres d’agissements qui constituent de la maltraitance des aînés, ainsi que les signes et les symptômes observés au bureau qui pourraient pointer vers des cas de mauvais traitements. La détection de tels cas pourrait être facilitée par le recours à un court outil validé, comme l’Elder Abuse Suspicion Index. Conclusion Les médecins de famille peuvent jouer un rôle plus important dans la détection d’une éventuelle maltraitance des aînés. Une fois qu’on soupçonne de mauvais traitements, il existe dans la plupart des communautés des services sociaux ou des forces de l’ordre accessibles pour effectuer des évaluations plus approfondies et intervenir.

  19. Characterization of an RF plasma ion source for ion implantation

    SciTech Connect

    Kopalidis, Peter M.; Wan Zhimin

    2012-11-06

    A novel inductively coupled RF plasma ion source has been developed for use in a beamline ion implanter. Ion density data have been taken with an array of four Langmuir probes spaced equally at the source extraction arc slit. These provide ion density uniformity information as a function of source pressure, RF power and gas mixture composition. In addition, total extracted ion beam current data are presented for the same conditions. The comparative advantages of the RF source in terms of higher beam current, reduced maintenance and overall productivity improvement compared to a hot cathode source are discussed.

  20. Ion channel probes for scanning ion conductance microscopy.

    PubMed

    Zhou, Yi; Bright, Leonard K; Shi, Wenqing; Aspinwall, Craig A; Baker, Lane A

    2014-12-23

    The sensitivity and selectivity of ion channels provide an appealing opportunity for sensor development. Here, we describe ion channel probes (ICPs), which consist of multiple ion channels reconstituted into lipid bilayers suspended across the opening of perflourinated glass micropipets. When incorporated with a scanning ion conductance microscope (SICM), ICPs displayed a distance-dependent current response that depended on the number of ion channels in the membrane. With distance-dependent current as feedback, probes were translated laterally, to demonstrate the possibility of imaging with ICPs. The ICP platform yields several potential advantages for SICM that will enable exciting opportunities for incorporation of chemical information into imaging and for high-resolution imaging.

  1. Ion temperature via laser scattering on ion Bernstein waves

    SciTech Connect

    Wurden, G.A.; Ono, M.; Wong, K.L.

    1981-10-01

    Hydrogen ion temperature has been measured in a warm toroidal plasma with externally launched ion Bernstein waves detected by heterodyne CO/sub 2/ laser scattering. Radial scanning of the laser beam allows precise determination of k/sub perpendicular to/ for the finite ion Larmor radius wave (..omega.. approx. less than or equal to 2..cap omega../sub i/). Knowledge of the magnetic field strength and ion concentration then give a radially resolved ion temperature from the dispersion relation. Probe measurements and Doppler broadening of ArII 4806A give excellent agreement.

  2. What We Did Last Summer: Depicting DES Data to Enhance Simulation Utility and Use

    NASA Technical Reports Server (NTRS)

    Elfrey, Priscilla; Conroy, Mike; Lagares, Jose G.; Mann, David; Fahmi, Mona

    2009-01-01

    At Kennedy Space Center (KSC), an important use of Discrete Event Simulation (DES) addresses ground operations .of missions to space. DES allows managers, scientists and engineers to assess the number of missions KSC can complete on a given schedule within different facilities, the effects of various configurations of resources and detect possible problems or unwanted situations. For fifteen years, DES has supported KSC efficiency, cost savings and improved safety and performance. The dense and abstract DES data, however, proves difficult to comprehend and, NASA managers realized, is subject to misinterpretation, misunderstanding and even, misuse. In summer 2008, KSC developed and implemented a NASA Exploration Systems Mission Directorate (ESMD) project based on the premise that visualization could enhance NASA's understanding and use of DES.

  3. Approche à l’égard des nouveaux anticoagulants oraux en pratique familiale

    PubMed Central

    Douketis, James; Bell, Alan David; Eikelboom, John; Liew, Aaron

    2014-01-01

    Résumé Objectif Comparer les caractéristiques principales des nouveaux anticoagulants oraux (NACO), soit le dabigatran, le rivaroxaban et l’apixaban, et répondre aux questions qui font surface lors de la comparaison de ces agents. Qualité des données Une recherche dans PubMed a été effectuée afin de relever les études cliniques récentes (de janvier 2008 à la semaine 32 de 2013) portant sur l’emploi des NACO pour la prévention des AVC dans les cas de fibrillation auriculaire (FA) et pour le traitement de la thromboembolie veineuse aiguë. Message principal Selon 3 essais d’envergure, tous les NACO sont au moins aussi efficaces que la warfarine dans la prévention des AVC chez les patients atteints d’une FA non valvulaire, et au moins aussi sûrs pour ce qui est du risque de saignement. Des méta-analyses de ces essais ont montré que, comparativement au traitement par la warfarine, les NACO avaient réduit la mortalité totale, la mortalité d’origine cardiovasculaire et les saignements intracrâniens, et était aussi ressortie une tendance vers la réduction des saignements généraux. Du côté pratique, les avantages des NACO par rapport à la warfarine sont : posologie orale fixe uniquotidienne ou biquotidienne sans devoir surveiller la coagulation et peu d’interactions connues ou définies avec d’autres médicaments ou des aliments. Les désavantages potentiels des NACO sont notamment un risque de saignement qui serait accru chez les patients de plus de 75 ans, une hausse des saignements gastro-intestinaux majeurs avec des doses élevées de dabigatran, une hausse des cas de dyspepsie avec le dabigatran, l’absence d’un test de laboratoire de routine visant à mesurer de façon fiable l’effet anticoagulant et l’absence d’antidote pour renverser l’effet anticoagulant. Aucun essai randomisé contrôlé n’a effectué de comparaison directe des NACO, et le choix d’un NACO est influencé par les caract

  4. Prévalence des cervicalgies et douleurs des membres supérieures chez les utilisateurs d'ordinateur en milieu professionnel à Casablanca (Maroc)

    PubMed Central

    Seknaji, Nawal; Rachidi, Wafaa; Hassoune, Samira; Janani, Saadia; Nani, Samira; Maaroufi, Abderrahmane; Mkinsi, Ouafaa

    2013-01-01

    Introduction Les cervicalgies et douleurs du membre supérieur (CDMS) affectent des millions d'utilisateurs d'ordinateurs dans les pays développés. L'objectif de ce travail était de déterminer la prévalence des cervicalgies et douleurs du membre supérieur (CDMS) à Casablanca et identifier les différents facteurs de risque qui y sont impliqués, afin de définir les sous-groupes à haut risque, et d’établir des plans d'intervention efficaces. Méthodes Il s'agit d'une étude transversale, menée chez 118 employés de bureau francophones et utilisant l'ordinateur, à Casablanca. Les données ont été collectées de Décembre 2011 à Juin 2012, en utilisant la version française d'un questionnaire validé: Maastricht-Upper-extremity-Questionnaire. Résultats 118 utilisateurs d'ordinateur en milieu professionnel ont été recrutés. Parmi les employés enquêtés, 93% ont rapporté des CDMS localisées au moins à un site. Les plaintes les plus fréquemment rapportées étaient les douleurs des épaules et les cervicalgies (48,3% et 46,6% respectivement). Nous n'avons pas remarqué de différence significative des fréquences des douleurs selon le genre. Nos résultats concordent avec les données de la littérature où il existe un certain consensus quant à l'impact des mauvaises conditions ergonomiques sur les troubles musculo-squelettiques du membre supérieur en milieu professionnel. De même, les études récentes examinant les effets combinés et/ou interactifs tant des facteurs biomécaniques/physiques que de facteurs psychosociaux professionnels vont de pair avec nos résultats. Conclusion Il en ressort que les stratégies d'intervention visant à réduire les CDMS doivent agir essentiellement sur 3 volets, le premier correspond à l'amélioration et la sensibilisation quant au respect des conditions ergonomiques, le second concerne l'amélioration des conditions psychosociales. Enfin le troisième volet vise la rationalisant de la demande de

  5. Ion-ion dynamic structure factor of warm dense mixtures

    DOE PAGES

    Gill, N. M.; Heinonen, R. A.; Starrett, C. E.; Saumon, D.

    2015-06-25

    In this study, the ion-ion dynamic structure factor of warm dense matter is determined using the recently developed pseudoatom molecular dynamics method [Starrett et al., Phys. Rev. E 91, 013104 (2015)]. The method uses density functional theory to determine ion-ion pair interaction potentials that have no free parameters. These potentials are used in classical molecular dynamics simulations. This constitutes a computationally efficient and realistic model of dense plasmas. Comparison with recently published simulations of the ion-ion dynamic structure factor and sound speed of warm dense aluminum finds good to reasonable agreement. Using this method, we make predictions of the ion-ionmore » dynamical structure factor and sound speed of a warm dense mixture—equimolar carbon-hydrogen. This material is commonly used as an ablator in inertial confinement fusion capsules, and our results are amenable to direct experimental measurement.« less

  6. Resonant Ionization Laser Ion Source for Radioactive Ion Beams

    SciTech Connect

    Liu, Yuan; Beene, James R; Havener, Charles C; Vane, C Randy; Gottwald, T.; Wendt, K.; Mattolat, C.; Lassen, J.

    2009-01-01

    A resonant ionization laser ion source based on all-solid-state, tunable Ti:Sapphire lasers is being developed for the production of pure radioactive ion beams. It consists of a hot-cavity ion source and three pulsed Ti:Sapphire lasers operating at a 10 kHz pulse repetition rate. Spectroscopic studies are being conducted to develop ionization schemes that lead to ionizing an excited atom through an auto-ionization or a Rydberg state for numerous elements of interest. Three-photon resonant ionization of 12 elements has been recently demonstrated. The overall efficiency of the laser ion source measured for some of these elements ranges from 1 to 40%. The results indicate that Ti:Sapphire lasers could be well suited for laser ion source applications. The time structures of the ions produced by the pulsed lasers are investigated. The information may help to improve the laser ion source performance.

  7. Ion response in a weakly ionized plasma with ion flow

    SciTech Connect

    Kompaneets, Roman; Tyshetskiy, Yuriy O.; Vladimirov, Sergey V.

    2013-04-15

    We study the ion response to an initial perturbation in a weakly ionized plasma with ion flow driven by a dc electric field. The analysis is made by extending the classical Landau work [J. Phys. (USSR) 10, 25 (1946)] to the ion kinetic equation including ion-neutral collisions and a dc electric field. We show, in particular, that the complex frequencies of ion waves can be directly found from a known expression for the ion susceptibility [A. V. Ivlev et al., Phys. Rev. E 71, 016405 (2005); V. A. Schweigert, Phys. Rep. 27, 997 (2001)]; this is not obvious from its original derivation, because it only aims to describe the ion response for real frequencies.

  8. Design study of primary ion provider for relativistic heavy ion collider electron beam ion source.

    PubMed

    Kondo, K; Kanesue, T; Tamura, J; Okamura, M

    2010-02-01

    Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

  9. Prise en charge des traumatismes graves du rein

    PubMed Central

    Lakmichi, Mohamed Amine; Jarir, Redouane; Sadiki, Bader; Zehraoui; Bentani; Wakrim, Bader; Dahami, Zakaria; Moudouni; Sarf, Ismail

    2015-01-01

    Les traumatismes graves du rein de grade III, IV et V selon la classification de l'Amercan Society for Surgery For Trauma (ASST) sont plus rares et se retrouvent dans 5% des cas en moyenne. Leur prise en charge est souvent délicate, nécessitant alors des centres expérimentés dotés de moyen adéquats d'imagerie (scanner spiralé). Cependant, durant ces dernières années, la prise en charge de ces traumatismes a évolué vers une attitude de moins en moins chirurgicale grâce à l’évolution des techniques de la radiologie interventionnelle, de l'endourologie et des moyens de surveillance aux urgences et de réanimation. L'objectif de cette étude est d’évaluer notre expérience dans la prise en charge des traumatismes rénaux de haut grade. Notre étude rétrospective porte sur 25 cas de traumatismes grave du rein de grade III, IV et V selon la classification de l'ASST, colligés entre Janvier 2002 et Juin 2009 au service d'urologie du centre Hospitalier Universitaire Mohammed VI, Université Cadi Ayyad de Marrakech, Maroc. Nous avons étudié les données épidémiologiques, les signes cliniques et biologiques à l'admission (état de choc hémorragique, taux d'hémoglobine), les données radiologiques (échographie et scanner), les lésions associées, la prise en charge thérapeutique et les complications. L’âge moyen de nos patients était de 24,9 ans 15 et 58 ans, avec une prédominance masculine (sex-ratio = 7, 3). Le rein droit était intéressé dans 15 cas (60%). Le traumatisme rénal était fermé dans 15 cas, et ouvert par arme blanche dans 10 cas. Huit patients se sont présentés en état de choc hémorragique (32%). Une anémie inférieur à 10g /100ml a été observée dans 10 cas (40%). L'uroscanner fait systématiquement à l'admission a retrouvé un grade III (10 cas), grade IV (13 cas) et grade V (2 cas). La prise en charge a consisté en une exploration chirurgicale avec néphrectomie chez 2 cas de Grade IV pour une instabilité h

  10. Thermal analysis of the DES camera focal plate.

    SciTech Connect

    Guarino, V.; High Energy Physics

    2008-02-13

    A design specification for the DES Camera focal plate is to keep the deformation of the plate to less than 30 microns under operating conditions. Figure 1 shows the assembly of the focal plate, the support bipods and support ring, and the copper braid assemblies. Several studies were done to examine the deformation of the focal plate under different thermal and structural constraints. Simple hand calculations were also performed as a check of the finite element model and results. The main goal of this analysis was to determine the deformation of the plate and to understand what thermal and structural conditions are causing the deformation.

  11. DES exposure checker: Dark Energy Survey image quality control crowdsourcer

    NASA Astrophysics Data System (ADS)

    Melchior, Peter; Sheldon, Erin; Drlica-Wagner, Alex; Rykoff, Eli S.

    2015-11-01

    DES exposure checker renders science-grade images directly to a web browser and allows users to mark problematic features from a set of predefined classes, thus allowing image quality control for the Dark Energy Survey to be crowdsourced through its web application. Users can also generate custom labels to help identify previously unknown problem classes; generated reports are fed back to hardware and software experts to help mitigate and eliminate recognized issues. These problem reports allow rapid correction of artifacts that otherwise may be too subtle or infrequent to be recognized.

  12. [Ziedses des Plantes: inventor of planigraphy and subtraction].

    PubMed

    van Gijn, Jan; Gijselhart, Joost P

    2011-01-01

    Bernard George Ziedses des Plantes (1902-1993) trained in Utrecht, the Netherlands, as specialist in nervous diseases, but his lifelong passion was to improve X-ray imaging of living tissues. In the 1930s he not only built the first machine for planigraphy, in which the X-ray tube and the film moved together around the plane of interest, but he also designed the subtraction method to improve images after injection of contrast agents. Eventually a full-time radiologist, he also developed the 'somersault' technique of ventriculography and pioneered isotope scintigraphy.

  13. Slow Ion Interferometry

    NASA Astrophysics Data System (ADS)

    Erickson, Christopher; Durfee, Dallin

    2009-05-01

    We will discuss an ion interferometer which is under construction. The device will utilize a laser-cooled source of ^87Sr^+ ions which will be split and recombined using stimulated Raman transitions inside of a conducting cylinder. The interferometer will be able to measure electric and magnetic fields with unprecedented precision. Potential uses of the device include practical applications such as the precision measurement of the evolution of fields near solids to reveal their electronic structure. It will also be used for fundamental tests of the basic laws of electromagnetism and the search for a non-zero photon rest mass. The device should enable the detection of a possible photon rest mass more than 100 times smaller than previous laboratory experiments. We will discuss both the details of the device and the theory connecting deviations from Coulomb's inverse-square law to a theory of massive photons.

  14. Ion bipolar junction transistors

    PubMed Central

    Tybrandt, Klas; Larsson, Karin C.; Richter-Dahlfors, Agneta; Berggren, Magnus

    2010-01-01

    Dynamic control of chemical microenvironments is essential for continued development in numerous fields of life sciences. Such control could be achieved with active chemical circuits for delivery of ions and biomolecules. As the basis for such circuitry, we report a solid-state ion bipolar junction transistor (IBJT) based on conducting polymers and thin films of anion- and cation-selective membranes. The IBJT is the ionic analogue to the conventional semiconductor BJT and is manufactured using standard microfabrication techniques. Transistor characteristics along with a model describing the principle of operation, in which an anionic base current amplifies a cationic collector current, are presented. By employing the IBJT as a bioelectronic circuit element for delivery of the neurotransmitter acetylcholine, its efficacy in modulating neuronal cell signaling is demonstrated. PMID:20479274

  15. Oxygen and strontium isotope tracing of human migration at the Bell Beaker site Le Tumulus des Sables, France.

    NASA Astrophysics Data System (ADS)

    Willmes, Malte; James, Hannah; Boel, Ceridwen; Courtaud, Patrice; Chancerel, Antoine; McMorrow, Linda; Armstrong, Richard; Kinsley, Les; Aubert, Maxime; Eggins, Stephen; Moffat, Ian; Grün, Rainer

    2014-05-01

    Oxygen (δ18O) and strontium (87Sr/86Sr) isotopes were used as tools to investigate human migration at the early Bell Beaker site (2500-2000 BC) Le Tumulus des Sables, Saint-Laurent-Médoc, south-west France. The O and Sr isotope ratios measured in tooth enamel record the average dietary isotope signature ingested by that individual during their childhood. When this data is compared to the isotope signature of the burial site it can be used to indicate if the individual migrated into this area during their lifetime. The O isotopic composition of meteoric water changes depending on climate, temperature and quantity of precipitation. O isotope ratios in skeletal and dental remains are related to body water, which in turn is influenced by diet, physiology and climate. Most of the water consumed by large mammals comes from drinking water, typically sourced locally. Sr isotope ratios on the other hand vary between different geologic regions, depending on their age and composition. Sr is released through weathering and transported into the soil, ground and surface water, where it becomes available for uptake by plants, enters the food cycle and eventually ends up in skeletal and dental tissue where it substitutes for calcium. We analysed the teeth of 18 adult and 8 juvenile disarticulated skeletons from Le Tumulus des Sables. O isotopes were analysed in-situ by Sensitive High Resolution Ion Micro Probe (SHRIMP).The Sr isotope analysis involved drilling a 0.2-0.5 mg sample of enamel from the tooth. The Sr was then chemically separated and analysed by Thermal Ionization Mass Spectrometry (TIMS). These results were then compared to the O isoscape of Europe and bioavailable Sr isotope data (fauna, plants, soils) from the IRHUM database. We found that most of the individuals at Le Tumulus des Sables show O and Sr isotope ratios corresponding to the local environmental signal and we interpret these as part of the local population. 3 adults however show slightly higher 87Sr/86

  16. Le syndrome des brides amniotiques et ses difficultés diagnostiques et de prise en charge au Burkina Faso

    PubMed Central

    Nagalo, Kisito; Badiel, Roger; Kouéta, Fla; Tall, François Housséini; Yé, Diarra

    2015-01-01

    Le syndrome des brides amniotiques est une embryo-foetopathie rare, d’étiopathogénie encore inconnue, caractérisé par des malformations crânio-faciales, thoraco-abdominales, des membres et des extrémités. Afin de discuter des difficultés diagnostiques et thérapeutiques du syndrome des brides amniotiques, nous rapportons cinq cas de ce syndrome. Ces cas représentaient autant de phénotypes de la maladie mais avec quelques singularités. Les deux premiers étaient des cas de maladie des brides amniotiques caractérisés l'un par une amputation d'un membre inférieur associée à des lésions cutanées et à une surdité, l'autre par des strictions avec amputation des doigts associées à une fente labio-palatine, une cataracte congénitale et un strabisme. Les trois autres cas correspondaient à des formes létales du Limb Body Wall Complex dont deux avec attache placento-crânienne et un avec attache placento-abdominale. Le renforcement du diagnostic anténatal, l'instauration du conseil génétique et la mise en place d'un registre national des malformations devraient permettre d'améliorer la prise en charge des cas du syndrome des brides amniotiques. PMID:26113939

  17. Ion cloud model for a linear quadrupole ion trap.

    PubMed

    Douglas, Don J; Konenkov, Nikolai V

    2012-01-01

    If large numbers of ions are stored in a linear quadrupole ion trap, space charge causes the oscillation frequencies of ions to decrease. Ions then appear at higher apparent masses when resonantly ejected for mass analysis. In principle, to calculate mass shifts requires calculating the positions of all ions, interacting with each other, at all times, with a self-consistent space charge field. Here, we propose a simpler model for the ion cloud in the case where mass shifts and frequency shifts are relatively small (ca 0.2% and 0.4%, respectively), the trapping field is much stronger (ca × 10(2)) than the space charge field and space charge only causes small perturbations to the ion motion. The self-consistent field problem need not be considered. As test ions move with times long compared to a cycle of the trapping field, the motion of individual ions can be ignored. Static positions of the ions in the cloud are used. To generate an ion cloud, trajectories of N (ca 10,000) ions are calculated for random times between 10 and 100 cycles of the trapping radio frequency field. The ions are then distributed axially randomly in a trap four times the field radius, r(0) in length. The potential and electric field from the ion cloud are calculated from the ion positions. Near the trap center (distances r< 1r(0)), the potential and electric fields from space charge are not cylindrically symmetric, but are quite symmetric for greater values of r. Trajectories of test ions, oscillation frequencies and mass shifts can then be calculated in the trapping field, including the space charge field. Mass shifts are in good agreement with experiments for reasonable values of the initial positions and speeds of the ions. Agreement with earlier analytical models for the ion cloud, based on a uniform occupation of phase space, or a thermal (Boltzmann) distribution of ions trapped in the effective potential [D. Douglas and N.V. Konenkov, Rapid Commun. Mass Spectrom. 26, 2105 (2012)] is

  18. Experimental Evaluation of a Negative Ion Source for a Heavy Ion Fusion Negative Ion Driver

    SciTech Connect

    Grisham, L. R.; Hahto, S. K.; Hahto, S. T.; Kwan, J. W.; Leung, K. N.

    2004-06-16

    Negative halogen ions have recently been proposed as a possible alternative to positive ions for heavy ion fusion drivers because electron accumulation would not be a problem in the accelerator, and if desired, the beams could be photo-detached to neutrals. To test the ability to make suitable quality beams, an experiment was conducted at Lawrence Berkeley National Laboratory using chlorine in an RF-driven ion source. Without introducing any cesium (which is required to enhance negative ion production in hydrogen ion sources) a negative chlorine current density of 45 mA/cm{sup 2} was obtained under the same conditions that gave 57 45 mA/cm{sup 2} of positive chlorine, suggesting the presence of nearly as many negative ions as positive ions in the plasma near the extraction plane. The negative ion spectrum was 99.5% atomic chlorine ions, with only 0.5% molecular chlorine, and essentially no impurities. Although this experiment did not incorporate the type of electron suppression technology that i s used in negative hydrogen beam extraction, the ratio of co-extracted electrons to Cl{sup -} was as low as 7 to 1, many times lower than the ratio of their mobilities, suggesting that few electrons are present in the near-extractor plasma. This, along with the near-equivalence of the positive and negative ion currents, suggests that the plasma in this region was mostly an ion-ion plasma. The negative chlorine current density was relatively insensitive to pressure, and scaled linearly with RF power. If this linear scaling continues to hold at higher RF powers, it should permit current densities of 100 45 mA/cm{sup 2}, sufficient for present heavy ion fusion injector concepts. The effective ion temperatures of the positive and negative ions appeared to be similar and relatively low for a plasma source.

  19. Fast Ion Conductors

    NASA Astrophysics Data System (ADS)

    Chadwick, Alan V.

    Fast ion conductors, sometimes referred to as superionic conductors or solid electrolytes, are solids with ionic conductivities that are comparable to those found in molten salts and aqueous solutions of strong electrolytes, i.e., 10-2-10 S cm-1. Such materials have been known of for a very long time and some typical examples of the conductivity are shown in Fig. 1, along with sodium chloride as the archetypal normal ionic solid. Faraday [1] first noted the high conductivity of solid lead fluoride (PbF2) and silver sulphide (Ag2S) in the 1830s and silver iodide was known to be unusually high ionic conductor to the German physicists early in the 1900s. However, the materials were regarded as anomalous until the mid 1960s when they became the focus of intense interest to academics and technologists and they have remained at the forefront of materials research [2-4]. The academic aim is to understand the fundamental origin of fast ion behaviour and the technological goal is to utilize the properties in applications, particularly in energy applications such as the electrolyte membranes in solid-state batteries and fuel cells, and in electrochemical sensors. The last four decades has seen an expansion of the types of material that exhibit fast ion behaviour that now extends beyond simple binary ionic crystals to complex solids and even polymeric materials. Over this same period computer simulations of solids has also developed (in fact these methods and the interest in fast ion conductors were almost coincidental in their time of origin) and the techniques have played a key role in this area of research.

  20. Directly Driven Ion Outflow

    NASA Technical Reports Server (NTRS)

    Elliott, H. A.; Comfort, R. H.; Craven, P. D.; Moore, T. E.; Russell, C. T.; Rose, M. Franklin (Technical Monitor)

    2001-01-01

    We examine ionospheric outflows in the high altitude magnetospheric polar cap during the POLAR satellite's apogee on April 19, 1996 using the Thermal Ion Dynamics Experiment (TIDE) instrument. The elevated levels of O(+) observed in this pass may be due to the geophysical conditions during and prior to the apogee pass. In addition to the high abundance of O(+) relative to H(+), several other aspects of this data are noteworthy. We observe relationships between the density, velocity, and temperature which appear to be associated with perpendicular heating and the mirror force, rather than adiabatic expansion. The H(+) outflow is at a fairly constant flux which is consistent with being source limited by charge exchange at lower altitudes. Local centrifugal acceleration in the polar cap is found to be insufficient to account for the main variations we observe in the outflow velocity. The solar wind speed is high during this pass approximately 700 kilometers per second, and there are Alfve'n waves present in the solar wind such that the solar wind speed and IMF Bx are correlated. In this pass both the H(+) and O(+) outflow velocities correlate with both the solar wind speed and IMF fluctuations. Polar cap magnetometer and Hydra electron data show the same long period wave structure as found in the solar wind and polar cap ion outflow. In addition, the polar cap Poynting flux along the magnetic field direction correlates well with the H(+) temperature (R=0.84). We conclude that the solar wind can drive polar cap ion outflow particularly during polar squalls by setting up a parallel drop that is tens of eV which then causes the ion outflow velocity of O(+) and H(+), the electrons, and magnetic perturbations to vary in a similar fashion.

  1. Recombination of cluster ions

    NASA Technical Reports Server (NTRS)

    Johnsen, Rainer

    1993-01-01

    Some of our recent work on molecular band emissions from recombination of molecular dimer ions (N4(+) and CO(+) CO) is discussed. Much of the experimental work was done by Y. S. Cao; the results on N4(+) recombination have been published. A brief progress report is given on our ongoing measurements of neutral products of recombination using the flowing-afterglow Langmuir-probe technique in conjunction with laser-induced fluorescence.

  2. Ion Collision, Theory

    SciTech Connect

    Shukla, Anil K.

    2013-09-11

    The outcome of a collision between an ion and neutral species depends on the chemical and physical properties of the two reactants, their relative velocities, and the impact parameter of their trajectories. These include elastic and inelastic scattering of the colliding particles, charge transfer (including dissociative charge transfer), atom abstraction, complex formation and dissociation of the colliding ion. Each of these reactions may be characterized in terms of their energy-dependent rate coefficients, cross sections and reaction kinetics. A theoretical framework that emphasizes simple models and classical mechanics is presented for these processes. Collision processes are addressed in two categories of low-energy and high-energy collisions. Experiments under thermal or quasi-thermal conditions–swarms, drift tubes, chemical ionization and ion cyclotron resonance are strongly influenced by long-range forces and often involve collisions in which atom exchange and extensive energy exchange are common characteristics. High-energy collisions are typically impulsive, involve short-range intermolecular forces and are direct, fast processes.

  3. Ion channeling revisited

    SciTech Connect

    Doyle, Barney Lee; Corona, Aldo; Nguyen, Anh

    2014-09-01

    A MS Excel program has been written that calculates accidental, or unintentional, ion channeling in cubic bcc, fcc and diamond lattice crystals or polycrystalline materials. This becomes an important issue when simulating the creation by energetic neutrons of point displacement damage and extended defects using beams of ions. All of the tables and graphs in the three Ion Beam Analysis Handbooks that previously had to be manually looked up and read from were programed into Excel in handy lookup tables, or parameterized, for the case of the graphs, using rather simple exponential functions with different powers of the argument. The program then offers an extremely convenient way to calculate axial and planar half-angles and minimum yield or dechanneling probabilities, effects on half-angles of amorphous overlayers, accidental channeling probabilities for randomly oriented crystals or crystallites, and finally a way to automatically generate stereographic projections of axial and planar channeling half-angles. The program can generate these projections and calculate these probabilities for axes and [hkl] planes up to (555).

  4. Negative ion source

    DOEpatents

    Delmore, James E.

    1987-01-01

    A method and apparatus for providing a negative ion source accelerates electrons away from a hot filament electron emitter into a region of crossed electric and magnetic fields arranged in a magnetron configuration. During a portion of the resulting cycloidal path, the electron velocity is reduced below its initial value. The electron accelerates as it leaves the surface at a rate of only slightly less than if there were no magnetic field, thereby preventing a charge buildup at the surface of the emitter. As the electron traverses the cycloid, it is decelerated during the second, third, and fourth quadrants, then reeccelerated as it approaches the end of the fourth quadrant to regain its original velocity. The minimum velocity occurs during the fourth quadrant, and corresponds to an electron temperature of 200.degree. to 500.degree. for the electric and magnetic fields commonly encountered in the ion sources of magnetic sector mass spectrometers. An ion source using the above-described thermalized electrons is also disclosed.

  5. Ion aggregation in high salt solutions: Ion network versus ion cluster

    SciTech Connect

    Kim, Seongheun; Kim, Heejae; Choi, Jun-Ho; Cho, Minhaeng

    2014-09-28

    The critical aggregation phenomena are ubiquitous in many self-assembling systems. Ions in high salt solutions could also spontaneously form larger ion aggregates, but their effects on hydrogen-bond structures in water have long been controversial. Here, carrying out molecular dynamics (MD) simulation studies of high salt solutions and comparing the MD simulation results with infrared absorption and pump-probe spectroscopy of O–D stretch mode of HDO in highly concentrated salt solutions and {sup 13}C-NMR chemical shift of S{sup 13}CN{sup −} in KSCN solutions, we find evidence on the onset of ion aggregate and large-scale ion-ion network formation that concomitantly breaks water hydrogen-bond structure in certain salt solutions. Despite that these experimental results cannot provide direct evidence on the three-dimensional morphological structures of ion aggregates, they serve as reference data for verifying MD simulation methods. The MD results suggest that disrupted water hydrogen-bond network is intricately intertwined with ion-ion network. This further shows morphological variation of ion aggregate structures from ion cluster to ion network in high salt solutions that are interrelated to the onset of macroscopic aggregate formation and the water hydrogen-bond structure making and breaking processes induced by Hofmeister ions.

  6. Measurements of ion-ion collisional broadening of ion acoustic modes

    NASA Astrophysics Data System (ADS)

    Tierney, T. E.; Benage, J. F.; Montgomery, D. S.; Murillo, M. S.; Wysocki, F. J.; Rostoker, N.

    2002-10-01

    Although collisional plasmas are often encountered in inertial confinement fusion, dense plasma experiments and astrophysics, very few experiments have looked at the effects produced by the presence of these collisions. Ion-acoustic modes are predicted to broaden due to ion-ion collisions when the ion-ion mean free path, λ_ii, becomes comparable to the ion-acoustic wavelength, λ_iaw. This paper presents the first quantitative data of ion-acoustic wave broadening in moderately ion-ion collisional (0.05ion-acoustic modes was observed using collective Thomson scattering and analyzed using a collisional model that includes, ion and electron Landau, inhomogeneity and instrumental broadening. The results indicate that standard collisional models do not adequately predict the degree of ion-acoustic damping when 0.1

  7. Integration des sciences et de la langue: Creation et experimentation d'un modele pedagogique pour ameliorer l'apprentissage des sciences en milieu francophone minoritaire

    NASA Astrophysics Data System (ADS)

    Cormier, Marianne

    Les faibles resultats en sciences des eleves du milieu francophone minoritaire, lors d'epreuves au plan national et international, ont interpelle la recherche de solutions. Cette these avait pour but de creer et d'experimenter un modele pedagogique pour l'enseignement des sciences en milieu linguistique minoritaire. En raison de la presence de divers degres de francite chez la clientele scolaire de ce milieu, plusieurs elements langagiers (l'ecriture, la discussion et la lecture) ont ete integres a l'apprentissage scientifique. Nous avions recommande de commencer le processus d'apprentissage avec des elements langagiers plutot informels (redaction dans un journal, discussions en dyades...) pour progresser vers des activites langagieres plus formelles (redaction de rapports ou d'explications scientifiques). En ce qui a trait a l'apprentissage scientifique, le modele preconisait une demarche d'evolution conceptuelle d'inspiration socio-constructiviste tout en s'appuyant fortement sur l'apprentissage experientiel. Lors de l'experimentation du modele, nous voulions savoir si celui-ci provoquait une evolution conceptuelle chez les eleves, et si, simultanement, le vocabulaire scientifique de ces derniers s'enrichissait. Par ailleurs, nous cherchions a comprendre comment les eleves vivaient leurs apprentissages dans le cadre de ce modele pedagogique. Une classe de cinquieme annee de l'ecole de Grande-Digue, dans le Sud-est du Nouveau-Brunswick, a participe a la mise a l'essai du modele en etudiant les marais sales locaux. Lors d'entrevues initiales, nous avons remarque que les connaissances des eleves au sujet des marais sales etaient limitees. En effet, s'ils etaient conscients que les marais etaient des lieux naturels, ils ne pouvaient pas necessairement les decrire avec precision. Nous avons egalement constate que les eleves utilisaient surtout des mots communs (plantes, oiseaux, insectes) pour decrire le marais. Les resultats obtenus indiquent que les eleves ont

  8. Ion Cyclotron Waves at Titan

    NASA Astrophysics Data System (ADS)

    Russell, C. T.; Wei, H.; Cowee, M.; Neubauer, F. M.; Dougherty, M. K.

    2014-12-01

    The observation of ion cyclotron waves was generally expected well before Cassini arrived at Titan in 2004, because strong ion cyclotron waves were seen at Io where its atmosphere interacted with the corotating magnetospheric plasma. However, the region of the interaction of the Saturnian magnetospheric plasma with the Titan atmosphere has been quite devoid of ion cyclotron waves. Finally, on pass T63, ion cyclotron waves were seen briefly. More recently, on pass T98, a longer sequence of ion cyclotron waves also occurred. On pass T63, the pick-up ion signature is that of both H+ and H2+, while on pass T98, only H+ ion cyclotron waves are observed. We examine the strength of these waves and their region of occurrence in the light of our previous work on the expected occurrence of these waves.

  9. Ion beam probe diagnostic system

    NASA Astrophysics Data System (ADS)

    Hickok, R. L.; Jennings, W. C.; Woo, J. T.; Connor, K. A.

    1980-07-01

    Tokomak plasmas suitable for diagnostic development were produced in RENTOR following technological improvements in the vacuum chamber and discharge cleaning systems. Secondary ion signals were obtained from the heavy ion beam probe on RENTOR leading to initial estimates of the plasma space potential, which appears to vary by several hundred volts during the plasma pulse. The principle of measuring space potential in a minimum-B geometry was established using an ion gun mounted at the center of the ALEX baseball coil. The neutral beam probe was installed for measuring the space potential using actual secondary ion signals from a hollow cathode arc in ALEX and preliminary tests have begun. The ion beam test stand was significantly altered to allow more flexibility in testing energy analyzers, ion guns, and ion focusing concepts.

  10. [Herodotus on the adventurous career of the famous Greek physician Democédes].

    PubMed

    Frølandl, Anders

    2014-01-01

    In the latter half of the sixth century BC the physician Democédes left Croton, a Greek settlement in Southern Italy, in order to practice and gain an income and perhaps fame. He first arrived in the island of Aigina, where he soon became very famous and was offered a substantial fee for serving the inhabitants of the island. He then moved to Athens and after a year he became physician to the tyrant Polykrátes of Samos. When the tyrant was murdered, he was enslaved by the new ruler, but he too was killed. Finally Democédes fell into the hands of the Persian king, Dareios the first, still fettered as the other slaves. When the king sprained his ancle seriously, his Egyptian court doctors were helpless. Someone knew that Democédes was a skillful physician, so he was sent for and appeared in chains and rags. After having cured the king he was very generously rewarded. Democédes only wanted to go back to Hellas, but the king would not let him. Later Democ,des cured the favourite wife of the king, Atossa, of an abscess of the breast. Democédes persuaded her to encourage the king to send a scouting expedition including Democédes to Greece in order to prepare for war. Democédes managed to escape from the ship and after some further troubles he succeeded to remain in his native town of Croton. The story contains many folkloristic motives and is certainly not historically correct. But it is well known that young Greek doctors often travelled around as Democédes did and that Greek doctors came to replace their Egyptian colleagues at the courts of the local rulers. Herodotus wrote down the adventures of Democédes about one hundred years after they may have taken place, and this simple fact probably accounts for some of the dramatic details of the story. The tale of Democédes illustrates the interests of Herodotus and of Hippocrates too in foreign people and the reasons why the Greek of the fifth century were so successful compared to others. Here Democédes

  11. Ion sources for energy extremes of ion implantation.

    PubMed

    Hershcovitch, A; Johnson, B M; Batalin, V A; Kropachev, G N; Kuibeda, R P; Kulevoy, T V; Kolomiets, A A; Pershin, V I; Petrenko, S V; Rudskoy, I; Seleznev, D N; Bugaev, A S; Gushenets, V I; Litovko, I V; Oks, E M; Yushkov, G Yu; Masunov, E S; Polozov, S M; Poole, H J; Storozhenko, P A; Svarovski, A Ya

    2008-02-01

    For the past four years a joint research and development effort designed to develop steady state, intense ion sources has been in progress with the ultimate goal to develop ion sources and techniques that meet the two energy extreme range needs of meV and hundreads of eV ion implanters. This endeavor has already resulted in record steady state output currents of high charge state of antimony and phosphorus ions: P(2+) [8.6 pmA (particle milliampere)], P(3+) (1.9 pmA), and P(4+) (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb(3+)Sb(4+), Sb(5+), and Sb(6+) respectively. For low energy ion implantation, our efforts involve molecular ions and a novel plasmaless/gasless deceleration method. To date, 1 emA (electrical milliampere) of positive decaborane ions was extracted at 10 keV and smaller currents of negative decaborane ions were also extracted. Additionally, boron current fraction of over 70% was extracted from a Bernas-Calutron ion source, which represents a factor of 3.5 improvement over currently employed ion sources.

  12. ION SOURCES FOR ENERGY EXTREMES OF ION IMPLANTATION.

    SciTech Connect

    HERSCHCOVITCH,A.; JOHNSON, B.M.; BATALIN, V.A.; KROPACHEV, G.N.; KUIBEDA, R.P.; KULEVOY, T.V.; KOLOMIETS, A.A.; PERSHIN, V.I.; PETRENKO, S.V.; RUDSKOY, I.; SELEZNEV, D.N.; BUGAEV, A.S.; GUSHENETS, V.I.; LITOVKO, I.V.; OKS, E.M.; YUSHKOV, G. YU.; MASEUNOV, E.S.; POLOZOV, S.M.; POOLE, H.J.; STOROZHENKO, P.A.; SVAROVSKI, YA.

    2007-08-26

    For the past four years a joint research and development effort designed to develop steady state, intense ion sources has been in progress with the ultimate goal to develop ion sources and techniques, which meet the two energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. This endeavor has already resulted in record steady state output currents of high charge state of Antimony and Phosphorous ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. For low energy ion implantation our efforts involve molecular ions and a novel plasmaless/gasless deceleration method. To date, 1 emA of positive Decaborane ions were extracted at 10 keV and smaller currents of negative Decaborane ions were also extracted. Additionally, Boron current fraction of over 70% was extracted from a Bemas-Calutron ion source, which represents a factor of 3.5 improvement over currently employed ion sources.

  13. Characterization of Ion Dynamics in Structures for Lossless Ion Manipulations

    SciTech Connect

    Tolmachev, Aleksey V.; Webb, Ian K.; Ibrahim, Yehia M.; Garimella, Venkata BS; Zhang, Xinyu; Anderson, Gordon A.; Smith, Richard D.

    2014-08-23

    Structures for Lossless Ion Manipulation (SLIM) represent a novel class of ion optical devices based upon electrodes patterned on planar surfaces, and relying on a combined action of radio frequency and DC electric fields and specific buffer gas density conditions. Initial experimental studies have demonstrated the feasibility of the SLIM concept. This report offers an in-depth consideration of key ion dynamics properties in such devices based upon ion optics theory and computational modeling. The SLIM devices investigated are formed by two surfaces, each having an array of radio frequency (RF) "rung" electrodes, bordered by DC "guard" electrodes. Ion motion is confined by the RF effective potential in the direction orthogonal to the boards, and limited or controlled in the transversal direction by the guard DC potentials. Ions can be efficiently trapped and stored in SLIM devices where the confinement of ions can be ‘soft’ in regard to the extent of collisional activation, similarly to RF-only multipole ion guides and traps. The segmentation of the RF rung electrodes and guards along the axis makes it possible to apply electric field profiles to stimulate ion transfer within a SLIM. In the case of a linear DC gradient applied to RF rungs and guards, a virtually uniform electric field can be created along the axis of the device, enabling ion mobility separations.

  14. Ion Outflow At Mars Using MEX Ion And Electron Data

    NASA Astrophysics Data System (ADS)

    Fowler, Christopher M.; Andersson, L.; Lundin, R. N.; Frahm, R. A.

    2013-10-01

    How Mars lost it’s water and atmosphere is still an important question. Many studies have investigated high-energy ion fluxes (>10 eV) surrounding the planet and derived ion outflow rates in order to determine atmospheric loss. These rates suggest that the outflow from high-energy ions is not the dominant escape path for atmospheric loss. Over the years increasing evidence has indicated that the loss of low-energy ions is more important than the high-energy ion loss. In this presentation ion observations (down to the spacecraft potential) from the Mars Express (MEX) mission (2010/11), are used to describe the ion altitude distribution at Mars. The focus of this study is below the altitude of ~2000 km. Within the Mars environment, using the MEX electron observations different plasma regions were identified. Supported by electron identification, different altitude profiles of ion fluxes have been analyzed from the different plasma regions. The altitude profiles of the ion fluxes observed below the photoelectron boundary and in the sheath transition region in this study show large asymmetries between the northern and southern hemispheres. The ion distributions, resulting altitude profiles, the influence of the crustal magnetic field at Mars, and the implications relating to plasma outflow will be discussed in this presentation.

  15. Characterization of ion dynamics in structures for lossless ion manipulations.

    PubMed

    Tolmachev, Aleksey V; Webb, Ian K; Ibrahim, Yehia M; Garimella, Sandilya V B; Zhang, Xinyu; Anderson, Gordon A; Smith, Richard D

    2014-09-16

    Structures for Lossless Ion Manipulation (SLIM) represent a novel class of ion optical devices based upon electrodes patterned on planar surfaces, and relying on a combined action of radiofrequency and DC electric fields and specific buffer gas density conditions. Initial experimental studies have demonstrated the feasibility of the SLIM concept. This report offers an in-depth consideration of key ion dynamics properties in such devices based upon ion optics theory and computational modeling. The SLIM devices investigated are formed by two surfaces, each having an array of radiofrequency (RF) "rung" electrodes, bordered by DC "guard" electrodes. Ion motion is confined by the RF effective potential in the direction orthogonal to the boards and limited or controlled in the transversal direction by the guard DC potentials. Ions can be efficiently trapped and stored in SLIM devices where the confinement of ions can be "soft" in regard to the extent of collisional activation, similarly to RF-only multipole ion guides and traps. The segmentation of the RF rung electrodes and guards along the axis makes it possible to apply static or transient electric field profiles to stimulate ion transfer within a SLIM. In the case of a linear DC gradient applied to RF rungs and guards, a virtually uniform electric field can be created along the axis of the device, enabling high quality ion mobility separations. PMID:25152178

  16. Electron string ion sources for carbon ion cancer therapy accelerators.

    PubMed

    Boytsov, A Yu; Donets, D E; Donets, E D; Donets, E E; Katagiri, K; Noda, K; Ponkin, D O; Ramzdorf, A Yu; Salnikov, V V; Shutov, V B

    2015-08-01

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C(4+) and C(6+) ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 10(10) C(4+) ions per pulse and about 5 × 10(9) C(6+) ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 10(11) C(6+) ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the (11)C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C(4+) ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of (11)C, transporting to the tumor with the primary accelerated (11)C(4+) beam, this efficiency is preliminarily considered to be large enough to produce the (11)C(4+) beam from radioactive methane and to inject this beam into synchrotrons.

  17. Electron string ion sources for carbon ion cancer therapy accelerators.

    PubMed

    Boytsov, A Yu; Donets, D E; Donets, E D; Donets, E E; Katagiri, K; Noda, K; Ponkin, D O; Ramzdorf, A Yu; Salnikov, V V; Shutov, V B

    2015-08-01

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C(4+) and C(6+) ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 10(10) C(4+) ions per pulse and about 5 × 10(9) C(6+) ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 10(11) C(6+) ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the (11)C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C(4+) ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of (11)C, transporting to the tumor with the primary accelerated (11)C(4+) beam, this efficiency is preliminarily considered to be large enough to produce the (11)C(4+) beam from radioactive methane and to inject this beam into synchrotrons. PMID:26329182

  18. STATUS OF ITEP DECABORANE ION SOURCE PROGRAM.

    SciTech Connect

    KULEVOY,T.V.; PETRENKO, S.V.; KUIBEDA, R.P.; SELEZNEV, D.N.; KOZLOV, A.V.; STASEVICH, YU.B.; SITNIKOV, A.L.; SHAMAILOV, I.M.; PERSHIN, V.I.; HERSHCOVITCH, A.; JOHNSON, B.M.; GUSHENETS, V.I.; OKS, E.M.; POOLE, H.J.; MASUNOV, E.S.; POLOZOV, S.M.

    2007-08-26

    The joint research and development program is continued to develop steady-state ion source of decaborane beam for ion implantation industry. Both Freeman and Bemas ion sources for decaborane ion beam generation were investigated. Decaborane negative ion beam as well as positive ion beam were generated and delivered to the output of mass separator. Experimental results obtained in ITEP are presented.

  19. New apparatus increases ion beam power density

    NASA Technical Reports Server (NTRS)

    Baldwin, L. V.; Sandborn, V. A.

    1964-01-01

    To increase ion engine or rocket power, an ion source and emitter, an ion beam focusing electrode, and an ion accelerator are incorporated into the system. In operation the space charge surrounding the ion emitter decreases, the ion beam density accelerates, and engine power increases.

  20. Investigations of Sputtered Ion Production

    NASA Astrophysics Data System (ADS)

    Schauer, Stephen Nicholai

    Secondary Ion Mass Spectrometry is based on sputtered ion emission. Although the sputtering process was observed over 100 years ago, the ion emission process is still not well understood. Ions are formed with a wide range of energies, charge states and multiplicities, and ionization efficiencies can vary by orders of magnitude, depending on the particular ion and the matrix from which it originates. A series of studies are presented here which examine ion production in several unusual areas in order to gain insight into the sputtered ion emission process. The energy of analyzed ions is usually limited to 125 eV or less. The range of the Cameca IMS-3f at Arizona State University has been extended to analyze ions with up to 4500 eV of initial kinetic energy. The use of high energy ions to eliminate cluster interferences has been developed as an analytical technique. Doubly-charged positive ions of Mg, Al and Si have been widely studied. Other doubley-charged ions have been almost ignored, mainly due to low signal intensity. Studies of doubly-charged ions of the fourth row elements are presented here. The energy distribution of these ions indicates that they are formed by an Auger process, commonly referred to as the kinetic emission process. Small gas phase doubly-charged negative ions are very rare. Reports of atomic doubly-charged negative ions have been disproved, or were unable to be confirmed. Large molecules or clusters are able to accommodate a double -negative charge, because of the large separation between the two electrons. Observations of small carbon cluster dianions are discussed. The oscillations in intensity give an indication of their structure and stability. Electron bombardment can also cause the emission of ions from surfaces. There is some controversy as to whether the ions are desorbed directly from the sample, or are desorbed as neutrals and ionized above the sample by interaction with the electron beam or secondary electrons. Measurements of