Sample records for describes analytical methods

  1. Method and apparatus for detecting an analyte

    DOEpatents

    Allendorf, Mark D [Pleasanton, CA; Hesketh, Peter J [Atlanta, GA

    2011-11-29

    We describe the use of coordination polymers (CP) as coatings on microcantilevers for the detection of chemical analytes. CP exhibit changes in unit cell parameters upon adsorption of analytes, which will induce a stress in a static microcantilever upon which a CP layer is deposited. We also describe fabrication methods for depositing CP layers on surfaces.

  2. CTEPP STANDARD OPERATING PROCEDURE FOR PREPARATION OF SURROGATE RECOVERY STANDARD AND INTERNAL STANDARD SOLUTIONS FOR POLAR TARGET ANALYTES (SOP-5.26)

    EPA Science Inventory

    This SOP describes the method used for preparing surrogate recovery standard and internal standard solutions for the analysis of polar target analytes. It also describes the method for preparing calibration standard solutions for polar analytes used for gas chromatography/mass sp...

  3. Quantifying Acoustic Impacts on Marine Mammals and Sea Turtles: Methods and Analytical Approach for Phase III Training and Testing

    DTIC Science & Technology

    2017-06-16

    Acoustic Impacts on Marine Mammals and Sea Turtles: Methods and Analytical Approach for Phase III Training and Testing Sarah A. Blackstock Joseph O...December 2017 4. TITLE AND SUBTITLE Quantifying Acoustic Impacts on Marine Mammals and Sea Turtles: Methods and Analytical Approach for Phase III...Navy’s Phase III Study Areas as described in each Environmental Impact Statement/ Overseas Environmental Impact Statement and describes the methods

  4. Analytical capabilities and services of Lawrence Livermore Laboratory's General Chemistry Division. [Methods available at Lawrence Livermore

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gutmacher, R.; Crawford, R.

    This comprehensive guide to the analytical capabilities of Lawrence Livermore Laboratory's General Chemistry Division describes each analytical method in terms of its principle, field of application, and qualitative and quantitative uses. Also described are the state and quantity of sample required for analysis, processing time, available instrumentation, and responsible personnel.

  5. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  6. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  7. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  8. Exact analytic solutions of Maxwell's equations describing propagating nonparaxial electromagnetic beams.

    PubMed

    Garay-Avendaño, Roger L; Zamboni-Rached, Michel

    2014-07-10

    In this paper, we propose a method that is capable of describing in exact and analytic form the propagation of nonparaxial scalar and electromagnetic beams. The main features of the method presented here are its mathematical simplicity and the fast convergence in the cases of highly nonparaxial electromagnetic beams, enabling us to obtain high-precision results without the necessity of lengthy numerical simulations or other more complex analytical calculations. The method can be used in electromagnetism (optics, microwaves) as well as in acoustics.

  9. Methods of use for sensor based fluid detection devices

    NASA Technical Reports Server (NTRS)

    Lewis, Nathan S. (Inventor)

    2001-01-01

    Methods of use and devices for detecting analyte in fluid. A system for detecting an analyte in a fluid is described comprising a substrate having a sensor comprising a first organic material and a second organic material where the sensor has a response to permeation by an analyte. A detector is operatively associated with the sensor. Further, a fluid delivery appliance is operatively associated with the sensor. The sensor device has information storage and processing equipment, which is operably connected with the device. This device compares a response from the detector with a stored ideal response to detect the presence of analyte. An integrated system for detecting an analyte in a fluid is also described where the sensing device, detector, information storage and processing device, and fluid delivery device are incorporated in a substrate. Methods for use for the above system are also described where the first organic material and a second organic material are sensed and the analyte is detected with a detector operatively associated with the sensor. The method provides for a device, which delivers fluid to the sensor and measures the response of the sensor with the detector. Further, the response is compared to a stored ideal response for the analyte to determine the presence of the analyte. In different embodiments, the fluid measured may be a gaseous fluid, a liquid, or a fluid extracted from a solid. Methods of fluid delivery for each embodiment are accordingly provided.

  10. A technique for setting analytical thresholds in massively parallel sequencing-based forensic DNA analysis

    PubMed Central

    2017-01-01

    Amplicon (targeted) sequencing by massively parallel sequencing (PCR-MPS) is a potential method for use in forensic DNA analyses. In this application, PCR-MPS may supplement or replace other instrumental analysis methods such as capillary electrophoresis and Sanger sequencing for STR and mitochondrial DNA typing, respectively. PCR-MPS also may enable the expansion of forensic DNA analysis methods to include new marker systems such as single nucleotide polymorphisms (SNPs) and insertion/deletions (indels) that currently are assayable using various instrumental analysis methods including microarray and quantitative PCR. Acceptance of PCR-MPS as a forensic method will depend in part upon developing protocols and criteria that define the limitations of a method, including a defensible analytical threshold or method detection limit. This paper describes an approach to establish objective analytical thresholds suitable for multiplexed PCR-MPS methods. A definition is proposed for PCR-MPS method background noise, and an analytical threshold based on background noise is described. PMID:28542338

  11. A technique for setting analytical thresholds in massively parallel sequencing-based forensic DNA analysis.

    PubMed

    Young, Brian; King, Jonathan L; Budowle, Bruce; Armogida, Luigi

    2017-01-01

    Amplicon (targeted) sequencing by massively parallel sequencing (PCR-MPS) is a potential method for use in forensic DNA analyses. In this application, PCR-MPS may supplement or replace other instrumental analysis methods such as capillary electrophoresis and Sanger sequencing for STR and mitochondrial DNA typing, respectively. PCR-MPS also may enable the expansion of forensic DNA analysis methods to include new marker systems such as single nucleotide polymorphisms (SNPs) and insertion/deletions (indels) that currently are assayable using various instrumental analysis methods including microarray and quantitative PCR. Acceptance of PCR-MPS as a forensic method will depend in part upon developing protocols and criteria that define the limitations of a method, including a defensible analytical threshold or method detection limit. This paper describes an approach to establish objective analytical thresholds suitable for multiplexed PCR-MPS methods. A definition is proposed for PCR-MPS method background noise, and an analytical threshold based on background noise is described.

  12. Rapid and Automated Analytical Methods for Redox Species Based on Potentiometric Flow Injection Analysis Using Potential Buffers

    PubMed Central

    Ohura, Hiroki; Imato, Toshihiko

    2011-01-01

    Two analytical methods, which prove the utility of a potentiometric flow injection technique for determining various redox species, based on the use of some redox potential buffers, are reviewed. The first is a potentiometric flow injection method in which a redox couple such as Fe(III)-Fe(II), Fe(CN)6 3−-Fe(CN)(CN)6 4−, and bromide-bromine and a redox electrode or a combined platinum-bromide ion selective electrode are used. The analytical principle and advantages of the method are discussed, and several examples of its application are reported. Another example is a highly sensitive potentiometric flow injection method, in which a large transient potential change due to bromine or chlorine as an intermediate, generated during the reaction of the oxidative species with an Fe(III)-Fe(II) potential buffer containing bromide or chloride, is utilized. The analytical principle and details of the proposed method are described, and examples of several applications are described. The determination of trace amounts of hydrazine, based on the detection of a transient change in potential caused by the reaction with a Ce(IV)-Ce(III) potential buffer, is also described. PMID:21584280

  13. Nanostructure-initiator mass spectrometry biometrics

    DOEpatents

    Leclerc, Marion; Bowen, Benjamin; Northen, Trent

    2015-09-08

    Several embodiments described herein are drawn to methods of identifying an analyte on a subject's skin, methods of generating a fingerprint, methods of determining a physiological change in a subject, methods of diagnosing health status of a subject, and assay systems for detecting an analyte and generating a fingerprint, by nanostructure-initiator mass spectrometry (NIMS).

  14. Analytical resource assessment method for continuous (unconventional) oil and gas accumulations - The "ACCESS" Method

    USGS Publications Warehouse

    Crovelli, Robert A.; revised by Charpentier, Ronald R.

    2012-01-01

    The U.S. Geological Survey (USGS) periodically assesses petroleum resources of areas within the United States and the world. The purpose of this report is to explain the development of an analytic probabilistic method and spreadsheet software system called Analytic Cell-Based Continuous Energy Spreadsheet System (ACCESS). The ACCESS method is based upon mathematical equations derived from probability theory. The ACCESS spreadsheet can be used to calculate estimates of the undeveloped oil, gas, and NGL (natural gas liquids) resources in a continuous-type assessment unit. An assessment unit is a mappable volume of rock in a total petroleum system. In this report, the geologic assessment model is defined first, the analytic probabilistic method is described second, and the spreadsheet ACCESS is described third. In this revised version of Open-File Report 00-044 , the text has been updated to reflect modifications that were made to the ACCESS program. Two versions of the program are added as appendixes.

  15. An analytical method for designing low noise helicopter transmissions

    NASA Technical Reports Server (NTRS)

    Bossler, R. B., Jr.; Bowes, M. A.; Royal, A. C.

    1978-01-01

    The development and experimental validation of a method for analytically modeling the noise mechanism in the helicopter geared power transmission systems is described. This method can be used within the design process to predict interior noise levels and to investigate the noise reducing potential of alternative transmission design details. Examples are discussed.

  16. Analytic strategies to evaluate the association of time-varying exposures to HIV-related outcomes: Alcohol consumption as an example.

    PubMed

    Cook, Robert L; Kelso, Natalie E; Brumback, Babette A; Chen, Xinguang

    2016-01-01

    As persons with HIV are living longer, there is a growing need to investigate factors associated with chronic disease, rate of disease progression and survivorship. Many risk factors for this high-risk population change over time, such as participation in treatment, alcohol consumption and drug abuse. Longitudinal datasets are increasingly available, particularly clinical data that contain multiple observations of health exposures and outcomes over time. Several analytic options are available for assessment of longitudinal data; however, it can be challenging to choose the appropriate analytic method for specific combinations of research questions and types of data. The purpose of this review is to help researchers choose the appropriate methods to analyze longitudinal data, using alcohol consumption as an example of a time-varying exposure variable. When selecting the optimal analytic method, one must consider aspects of exposure (e.g. timing, pattern, and amount) and outcome (fixed or time-varying), while also addressing minimizing bias. In this article, we will describe several analytic approaches for longitudinal data, including developmental trajectory analysis, generalized estimating equations, and mixed effect models. For each analytic strategy, we describe appropriate situations to use the method and provide an example that demonstrates the use of the method. Clinical data related to alcohol consumption and HIV are used to illustrate these methods.

  17. Quantifying the measurement uncertainty of results from environmental analytical methods.

    PubMed

    Moser, J; Wegscheider, W; Sperka-Gottlieb, C

    2001-07-01

    The Eurachem-CITAC Guide Quantifying Uncertainty in Analytical Measurement was put into practice in a public laboratory devoted to environmental analytical measurements. In doing so due regard was given to the provisions of ISO 17025 and an attempt was made to base the entire estimation of measurement uncertainty on available data from the literature or from previously performed validation studies. Most environmental analytical procedures laid down in national or international standards are the result of cooperative efforts and put into effect as part of a compromise between all parties involved, public and private, that also encompasses environmental standards and statutory limits. Central to many procedures is the focus on the measurement of environmental effects rather than on individual chemical species. In this situation it is particularly important to understand the measurement process well enough to produce a realistic uncertainty statement. Environmental analytical methods will be examined as far as necessary, but reference will also be made to analytical methods in general and to physical measurement methods where appropriate. This paper describes ways and means of quantifying uncertainty for frequently practised methods of environmental analysis. It will be shown that operationally defined measurands are no obstacle to the estimation process as described in the Eurachem/CITAC Guide if it is accepted that the dominating component of uncertainty comes from the actual practice of the method as a reproducibility standard deviation.

  18. A sample preparation method for recovering suppressed analyte ions in MALDI TOF MS.

    PubMed

    Lou, Xianwen; de Waal, Bas F M; Milroy, Lech-Gustav; van Dongen, Joost L J

    2015-05-01

    In matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS), analyte signals can be substantially suppressed by other compounds in the sample. In this technical note, we describe a modified thin-layer sample preparation method that significantly reduces the analyte suppression effect (ASE). In our method, analytes are deposited on top of the surface of matrix preloaded on the MALDI plate. To prevent embedding of analyte into the matrix crystals, the sample solution were prepared without matrix and efforts were taken not to re-dissolve the preloaded matrix. The results with model mixtures of peptides, synthetic polymers and lipids show that detection of analyte ions, which were completely suppressed using the conventional dried-droplet method, could be effectively recovered by using our method. Our findings suggest that the incorporation of analytes in the matrix crystals has an important contributory effect on ASE. By reducing ASE, our method should be useful for the direct MALDI MS analysis of multicomponent mixtures. Copyright © 2015 John Wiley & Sons, Ltd.

  19. COMPARISON OF ANALYTICAL METHODS FOR THE MEASUREMENT OF NON-VIABLE BIOLOGICAL PM

    EPA Science Inventory

    The paper describes a preliminary research effort to develop a methodology for the measurement of non-viable biologically based particulate matter (PM), analyzing for mold, dust mite, and ragweed antigens and endotoxins. Using a comparison of analytical methods, the research obj...

  20. ANALYTICAL METHOD COMPARISONS BY ESTIMATES OF PRECISION AND LOWER DETECTION LIMIT

    EPA Science Inventory

    The paper describes the use of principal component analysis to estimate the operating precision of several different analytical instruments or methods simultaneously measuring a common sample of a material whose actual value is unknown. This approach is advantageous when none of ...

  1. EVALUATION OF ANALYTICAL REPORTING ERRORS GENERATED AS DESCRIBED IN SW-846 METHOD 8261A

    EPA Science Inventory

    SW-846 Method 8261A incorporates the vacuum distillation of analytes from samples, and their recoveries are characterized by internal standards. The internal standards measure recoveries with confidence intervals as functions of physical properties. The frequency the calculate...

  2. High resolution x-ray CMT: Reconstruction methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, J.K.

    This paper qualitatively discusses the primary characteristics of methods for reconstructing tomographic images from a set of projections. These reconstruction methods can be categorized as either {open_quotes}analytic{close_quotes} or {open_quotes}iterative{close_quotes} techniques. Analytic algorithms are derived from the formal inversion of equations describing the imaging process, while iterative algorithms incorporate a model of the imaging process and provide a mechanism to iteratively improve image estimates. Analytic reconstruction algorithms are typically computationally more efficient than iterative methods; however, analytic algorithms are available for a relatively limited set of imaging geometries and situations. Thus, the framework of iterative reconstruction methods is better suited formore » high accuracy, tomographic reconstruction codes.« less

  3. Enumeration of sugars and sugar alcohols hydroxyl groups by aqueous-based acetylation and MALDI-TOF mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    A method is described for enumerating hydroxyl groups on analytes in aqueous media is described, and applied to some common polyalcohols (erythritol, mannitol, and xylitol) and selected carbohydrates. The analytes were derivatized in water with vinyl acetate in presence of sodium phosphate buffer. ...

  4. Analytical Tools in School Finance Reform.

    ERIC Educational Resources Information Center

    Johns, R. L.

    This paper discusses the problem of analyzing variations in the educational opportunities provided by different school districts and describes how to assess the impact of school finance alternatives through use of various analytical tools. The author first examines relatively simple analytical methods, including calculation of per-pupil…

  5. Selected field and analytical methods and analytical results in the Dutch Flats area, western Nebraska, 1995-99

    USGS Publications Warehouse

    Verstraeten, Ingrid M.; Steele, G.V.; Cannia, J.C.; Bohlke, J.K.; Kraemer, T.E.; Hitch, D.E.; Wilson, K.E.; Carnes, A.E.

    2001-01-01

    A study of the water resources of the Dutch Flats area in the western part of the North Platte Natural Resources District, western Nebraska, was conducted from 1995 through 1999 to describe the surface water and hydrogeology, the spatial distribution of selected water-quality constituents in surface and ground water, and the surface-water/ground-water interaction in selected areas. This report describes the selected field and analytical methods used in the study and selected analytical results from the study not previously published. Specifically, dissolved gases, age-dating data, and other isotopes collected as part of an intensive sampling effort in August and November 1998 and all uranium and uranium isotope data collected through the course of this study are included in the report.

  6. Analysis methods for Kevlar shield response to rotor fragments

    NASA Technical Reports Server (NTRS)

    Gerstle, J. H.

    1977-01-01

    Several empirical and analytical approaches to rotor burst shield sizing are compared and principal differences in metal and fabric dynamic behavior are discussed. The application of transient structural response computer programs to predict Kevlar containment limits is described. For preliminary shield sizing, present analytical methods are useful if insufficient test data for empirical modeling are available. To provide other information useful for engineering design, analytical methods require further developments in material characterization, failure criteria, loads definition, and post-impact fragment trajectory prediction.

  7. Analytical procedures for water-soluble vitamins in foods and dietary supplements: a review.

    PubMed

    Blake, Christopher J

    2007-09-01

    Water-soluble vitamins include the B-group vitamins and vitamin C. In order to correctly monitor water-soluble vitamin content in fortified foods for compliance monitoring as well as to establish accurate data banks, an accurate and precise analytical method is a prerequisite. For many years microbiological assays have been used for analysis of B vitamins. However they are no longer considered to be the gold standard in vitamins analysis as many studies have shown up their deficiencies. This review describes the current status of analytical methods, including microbiological assays and spectrophotometric, biosensor and chromatographic techniques. In particular it describes the current status of the official methods and highlights some new developments in chromatographic procedures and detection methods. An overview is made of multivitamin extractions and analyses for foods and supplements.

  8. PFOS and PFOS: Analytics | Science Inventory | US EPA

    EPA Pesticide Factsheets

    This presentation describes the drivers for development of Method 537, the extraction and analytical procedure, performance data, holding time data as well as detection limits. The purpose of this presentation is to provide an overview of EPA drinking water Method 537 to the U.S. EPA Drinking Water Workshop participants.

  9. Automated dynamic analytical model improvement for damped structures

    NASA Technical Reports Server (NTRS)

    Fuh, J. S.; Berman, A.

    1985-01-01

    A method is described to improve a linear nonproportionally damped analytical model of a structure. The procedure finds the smallest changes in the analytical model such that the improved model matches the measured modal parameters. Features of the method are: (1) ability to properly treat complex valued modal parameters of a damped system; (2) applicability to realistically large structural models; and (3) computationally efficiency without involving eigensolutions and inversion of a large matrix.

  10. Analytical derivatives of the individual state energies in ensemble density functional theory method. I. General formalism

    DOE PAGES

    Filatov, Michael; Liu, Fang; Martínez, Todd J.

    2017-07-21

    The state-averaged (SA) spin restricted ensemble referenced Kohn-Sham (REKS) method and its state interaction (SI) extension, SI-SA-REKS, enable one to describe correctly the shape of the ground and excited potential energy surfaces of molecules undergoing bond breaking/bond formation reactions including features such as conical intersections crucial for theoretical modeling of non-adiabatic reactions. Until recently, application of the SA-REKS and SI-SA-REKS methods to modeling the dynamics of such reactions was obstructed due to the lack of the analytical energy derivatives. Here, the analytical derivatives of the individual SA-REKS and SI-SA-REKS energies are derived. The final analytic gradient expressions are formulated entirelymore » in terms of traces of matrix products and are presented in the form convenient for implementation in the traditional quantum chemical codes employing basis set expansions of the molecular orbitals. Finally, we will describe the implementation and benchmarking of the derived formalism in a subsequent article of this series.« less

  11. Techniques for Forecasting Air Passenger Traffic

    NASA Technical Reports Server (NTRS)

    Taneja, N.

    1972-01-01

    The basic techniques of forecasting the air passenger traffic are outlined. These techniques can be broadly classified into four categories: judgmental, time-series analysis, market analysis and analytical. The differences between these methods exist, in part, due to the degree of formalization of the forecasting procedure. Emphasis is placed on describing the analytical method.

  12. Validation of Analytical Damping Ratio by Fatigue Stress Limit

    NASA Astrophysics Data System (ADS)

    Foong, Faruq Muhammad; Chung Ket, Thein; Beng Lee, Ooi; Aziz, Abdul Rashid Abdul

    2018-03-01

    The optimisation process of a vibration energy harvester is usually restricted to experimental approaches due to the lack of an analytical equation to describe the damping of a system. This study derives an analytical equation, which describes the first mode damping ratio of a clamp-free cantilever beam under harmonic base excitation by combining the transverse equation of motion of the beam with the damping-stress equation. This equation, as opposed to other common damping determination methods, is independent of experimental inputs or finite element simulations and can be solved using a simple iterative convergence method. The derived equation was determined to be correct for cases when the maximum bending stress in the beam is below the fatigue limit stress of the beam. However, an increasing trend in the error between the experiment and the analytical results were observed at high stress levels. Hence, the fatigue limit stress was used as a parameter to define the validity of the analytical equation.

  13. Exact analytical approach for six-degree-of-freedom measurement using image-orientation-change method.

    PubMed

    Tsai, Chung-Yu

    2012-04-01

    An exact analytical approach is proposed for measuring the six-degree-of-freedom (6-DOF) motion of an object using the image-orientation-change (IOC) method. The proposed measurement system comprises two reflector systems, where each system consists of two reflectors and one position sensing detector (PSD). The IOCs of the object in the two reflector systems are described using merit functions determined from the respective PSD readings before and after motion occurs, respectively. The three rotation variables are then determined analytically from the eigenvectors of the corresponding merit functions. After determining the three rotation variables, the order of the translation equations is downgraded to a linear form. Consequently, the solution for the three translation variables can also be analytically determined. As a result, the motion transformation matrix describing the 6-DOF motion of the object is fully determined. The validity of the proposed approach is demonstrated by means of an illustrative example.

  14. Visual analytics for aviation safety: A collaborative approach to sensemaking

    NASA Astrophysics Data System (ADS)

    Wade, Andrew

    Visual analytics, the "science of analytical reasoning facilitated by interactive visual interfaces", is more than just visualization. Understanding the human reasoning process is essential for designing effective visualization tools and providing correct analyses. This thesis describes the evolution, application and evaluation of a new method for studying analytical reasoning that we have labeled paired analysis. Paired analysis combines subject matter experts (SMEs) and tool experts (TE) in an analytic dyad, here used to investigate aircraft maintenance and safety data. The method was developed and evaluated using interviews, pilot studies and analytic sessions during an internship at the Boeing Company. By enabling a collaborative approach to sensemaking that can be captured by researchers, paired analysis yielded rich data on human analytical reasoning that can be used to support analytic tool development and analyst training. Keywords: visual analytics, paired analysis, sensemaking, boeing, collaborative analysis.

  15. Knowledge, Skills, and Abilities for Entry-Level Business Analytics Positions: A Multi-Method Study

    ERIC Educational Resources Information Center

    Cegielski, Casey G.; Jones-Farmer, L. Allison

    2016-01-01

    It is impossible to deny the significant impact from the emergence of big data and business analytics on the fields of Information Technology, Quantitative Methods, and the Decision Sciences. Both industry and academia seek to hire talent in these areas with the hope of developing organizational competencies. This article describes a multi-method…

  16. Evaluation methodology for comparing memory and communication of analytic processes in visual analytics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ragan, Eric D; Goodall, John R

    2014-01-01

    Provenance tools can help capture and represent the history of analytic processes. In addition to supporting analytic performance, provenance tools can be used to support memory of the process and communication of the steps to others. Objective evaluation methods are needed to evaluate how well provenance tools support analyst s memory and communication of analytic processes. In this paper, we present several methods for the evaluation of process memory, and we discuss the advantages and limitations of each. We discuss methods for determining a baseline process for comparison, and we describe various methods that can be used to elicit processmore » recall, step ordering, and time estimations. Additionally, we discuss methods for conducting quantitative and qualitative analyses of process memory. By organizing possible memory evaluation methods and providing a meta-analysis of the potential benefits and drawbacks of different approaches, this paper can inform study design and encourage objective evaluation of process memory and communication.« less

  17. Rapid detection and identification of energetic materials with surface enhanced raman spectrometry (SERS)

    DOEpatents

    Han, Thomas Yong-Jin; Valdez, Carlos A; Olson, Tammy Y; Kim, Sung Ho; Satcher, Jr., Joe H

    2015-04-21

    In one embodiment, a system includes a plurality of metal nanoparticles functionalized with a plurality of organic molecules tethered thereto, wherein the plurality of organic molecules preferentially interact with one or more analytes when placed in proximity therewith. According to another embodiment, a method for detecting analytes includes contacting a fluid having one or more analytes of interest therein with a plurality of metal nanoparticles, each metal nanoparticle having a plurality of organic molecules tethered thereto, and detecting Raman scattering from an analyte of interest from the fluid, the analyte interacting with one or more of the plurality of organic molecules. In another embodiment, a method includes chemically modifying a plurality of cyclodextrin molecules at a primary hydroxyl moiety to create a chemical handle, and tethering the plurality of cyclodextrin molecules to a metal nanoparticle using the chemical handle. Other systems and methods for detecting analytes are also described.

  18. New Tools to Prepare ACE Cross-section Files for MCNP Analytic Test Problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Forrest B.

    Monte Carlo calculations using one-group cross sections, multigroup cross sections, or simple continuous energy cross sections are often used to: (1) verify production codes against known analytical solutions, (2) verify new methods and algorithms that do not involve detailed collision physics, (3) compare Monte Carlo calculation methods with deterministic methods, and (4) teach fundamentals to students. In this work we describe 2 new tools for preparing the ACE cross-section files to be used by MCNP ® for these analytic test problems, simple_ace.pl and simple_ace_mg.pl.

  19. Quantification of HCV RNA in Liver Tissue by bDNA Assay.

    PubMed

    Dailey, P J; Collins, M L; Urdea, M S; Wilber, J C

    1999-01-01

    With this statement, Sherlock and Dooley have described two of the three major challenges involved in quantitatively measuring any analyte in tissue samples: the distribution of the analyte in the tissue; and the standard of reference, or denominator, with which to make comparisons between tissue samples. The third challenge for quantitative measurement of an analyte in tissue is to ensure reproducible and quantitative recovery of the analyte on extraction from tissue samples. This chapter describes a method that can be used to measure HCV RNA quantitatively in liver biopsy and tissue samples using the bDNA assay. All three of these challenges-distribution, denominator, and recovery-apply to the measurement of HCV RNA in liver biopsies.

  20. Analytical approaches for MCPD esters and glycidyl esters in food and biological samples: a review and future perspectives.

    PubMed

    Crews, C; Chiodini, A; Granvogl, M; Hamlet, C; Hrnčiřík, K; Kuhlmann, J; Lampen, A; Scholz, G; Weisshaar, R; Wenzl, T; Jasti, P R; Seefelder, W

    2013-01-01

    Esters of 2 - and 3-monochloropropane-1,2-diol (MCPD) and glycidol esters are important contaminants of processed edible oils used as foods or food ingredients. This review describes the occurrence and analysis of MCPD esters and glycidol esters in vegetable oils and some other foods. The focus is on the analytical methods based on both direct and indirect methods. Methods of analysis applied to oils and lipid extracts of foods have been based on transesterification to free MCPD and determination by gas chromatography-mass spectrometry (indirect methods) and by high-performance liquid chromatography-mass spectrometry (direct methods). The evolution and performance of the different methods is described and their advantages and disadvantages are discussed. The application of direct and indirect methods to the analysis of foods and to research studies is described. The metabolism and fate of MCPD esters and glycidol esters in biological systems and the methods used to study these in body tissues studies are described. A clear understanding of the chemistry of the methods is important when choosing those suitable for the desired application, and will contribute to the mitigation of these contaminants.

  1. Progress and development of analytical methods for gibberellins.

    PubMed

    Pan, Chaozhi; Tan, Swee Ngin; Yong, Jean Wan Hong; Ge, Liya

    2017-01-01

    Gibberellins, as a group of phytohormones, exhibit a wide variety of bio-functions within plant growth and development, which have been used to increase crop yields. Many analytical procedures, therefore, have been developed for the determination of the types and levels of endogenous and exogenous gibberellins. As plant tissues contain gibberellins in trace amounts (usually at the level of nanogram per gram fresh weight or even lower), the sample pre-treatment steps (extraction, pre-concentration, and purification) for gibberellins are reviewed in details. The primary focus of this comprehensive review is on the various analytical methods designed to meet the requirements for gibberellins analyses in complex matrices with particular emphasis on high-throughput analytical methods, such as gas chromatography, liquid chromatography, and capillary electrophoresis, mostly combined with mass spectrometry. The advantages and drawbacks of the each described analytical method are discussed. The overall aim of this review is to provide a comprehensive and critical view on the different analytical methods nowadays employed to analyze gibberellins in complex sample matrices and their foreseeable trends. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A multiple hollow fibre liquid-phase microextraction method for the determination of halogenated solvent residues in olive oil.

    PubMed

    Manso, J; García-Barrera, T; Gómez-Ariza, J L; González, A G

    2014-02-01

    The present paper describes a method based on the extraction of analytes by multiple hollow fibre liquid-phase microextraction and detection by ion-trap mass spectrometry and electron capture detectors after gas chromatographic separation. The limits of detection are in the range of 0.13-0.67 μg kg(-1), five orders of magnitude lower than those reached with the European Commission Official method of analysis, with three orders of magnitude of linear range (from the quantification limits to 400 μg kg(-1) for all the analytes) and recoveries in fortified olive oils in the range of 78-104 %. The main advantages of the analytical method are the absence of sample carryover (due to the disposable nature of the membranes), high enrichment factors in the range of 79-488, high throughput and low cost. The repeatability of the analytical method ranged from 8 to 15 % for all the analytes, showing a good performance.

  3. CTEPP STANDARD OPERATING PROCEDURE FOR PREPARATION OF SURROGATE RECOVERY STANDARD AND INTERNAL STANDARD SOLUTIONS FOR NEUTRAL TARGET ANALYTES (SOP-5.25)

    EPA Science Inventory

    This standard operating procedure describes the method used for preparing internal standard, surrogate recovery standard and calibration standard solutions for neutral analytes used for gas chromatography/mass spectrometry analysis.

  4. CTEPP STANDARD OPERATING PROCEDURE FOR DETECTION AND QUANTIFICATION OF TARGET ANALYTES BY GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS) (SOP-5.24)

    EPA Science Inventory

    This standard operating procedure describes the method used for the determination of target analytes in sample extracts and related quality assurance/quality control sample extracts generated in the CTEPP study.

  5. Facilitating Personal Transformations in Small Groups: Part I.

    ERIC Educational Resources Information Center

    Boyd, Robert D.

    1989-01-01

    Describes personal transformation in small groups method that employs Matrix Model as its operational structure in Part I of two-part article. Describes method's reliance on metaphors and nature and manner in which they are employed. Defines personal transformation within framework of analytical psychology. (Author/CM)

  6. Solvent effects in time-dependent self-consistent field methods. II. Variational formulations and analytical gradients

    DOE PAGES

    Bjorgaard, J. A.; Velizhanin, K. A.; Tretiak, S.

    2015-08-06

    This study describes variational energy expressions and analytical excited state energy gradients for time-dependent self-consistent field methods with polarizable solvent effects. Linear response, vertical excitation, and state-specific solventmodels are examined. Enforcing a variational ground stateenergy expression in the state-specific model is found to reduce it to the vertical excitation model. Variational excited state energy expressions are then provided for the linear response and vertical excitation models and analytical gradients are formulated. Using semiempiricalmodel chemistry, the variational expressions are verified by numerical and analytical differentiation with respect to a static external electric field. Lastly, analytical gradients are further tested by performingmore » microcanonical excited state molecular dynamics with p-nitroaniline.« less

  7. Rational quality assessment procedure for less-investigated herbal medicines: Case of a Congolese antimalarial drug with an analytical report.

    PubMed

    Tshitenge, Dieudonné Tshitenge; Ioset, Karine Ndjoko; Lami, José Nzunzu; Ndelo-di-Phanzu, Josaphat; Mufusama, Jean-Pierre Koy Sita; Bringmann, Gerhard

    2016-04-01

    Herbal medicines are the most globally used type of medical drugs. Their high cultural acceptability is due to the experienced safety and efficiency over centuries of use. Many of them are still phytochemically less-investigated, and are used without standardization or quality control. Choosing SIROP KILMA, an authorized Congolese antimalarial phytomedicine, as a model case, our study describes an interdisciplinary approach for a rational quality assessment of herbal drugs in general. It combines an authentication step of the herbal remedy prior to any fingerprinting, the isolation of the major constituents, the development and validation of an HPLC-DAD analytical method with internal markers, and the application of the method to several batches of the herbal medicine (here KILMA) thus permitting the establishment of a quantitative fingerprint. From the constitutive plants of KILMA, acteoside, isoacteoside, stachannin A, and pectolinarigenin-7-O-glucoside were isolated, and acteoside was used as the prime marker for the validation of an analytical method. This study contributes to the efforts of the WHO for the establishment of standards enabling the analytical evaluation of herbal materials. Moreover, the paper describes the first phytochemical and analytical report on a marketed Congolese phytomedicine. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Method development and qualification of capillary zone electrophoresis for investigation of therapeutic monoclonal antibody quality.

    PubMed

    Suba, Dávid; Urbányi, Zoltán; Salgó, András

    2016-10-01

    Capillary electrophoresis techniques are widely used in the analytical biotechnology. Different electrophoretic techniques are very adequate tools to monitor size-and charge heterogenities of protein drugs. Method descriptions and development studies of capillary zone electrophoresis (CZE) have been described in literature. Most of them are performed based on the classical one-factor-at-time (OFAT) approach. In this study a very simple method development approach is described for capillary zone electrophoresis: a "two-phase-four-step" approach is introduced which allows a rapid, iterative method development process and can be a good platform for CZE method. In every step the current analytical target profile and an appropriate control strategy were established to monitor the current stage of development. A very good platform was established to investigate intact and digested protein samples. Commercially available monoclonal antibody was chosen as model protein for the method development study. The CZE method was qualificated after the development process and the results were presented. The analytical system stability was represented by the calculated RSD% value of area percentage and migration time of the selected peaks (<0.8% and <5%) during the intermediate precision investigation. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Spatially resolved thermal desorption/ionization coupled with mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jesse, Stephen; Van Berkel, Gary J; Ovchinnikova, Olga S

    2013-02-26

    A system and method for sub-micron analysis of a chemical composition of a specimen are described. The method includes providing a specimen for evaluation and a thermal desorption probe, thermally desorbing an analyte from a target site of said specimen using the thermally active tip to form a gaseous analyte, ionizing the gaseous analyte to form an ionized analyte, and analyzing a chemical composition of the ionized analyte. The thermally desorbing step can include heating said thermally active tip to above 200.degree. C., and positioning the target site and the thermally active tip such that the heating step forms themore » gaseous analyte. The thermal desorption probe can include a thermally active tip extending from a cantilever body and an apex of the thermally active tip can have a radius of 250 nm or less.« less

  10. 40 CFR 408.61 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory...

  11. 40 CFR 408.71 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217. (c...

  12. 40 CFR 408.81 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... components of a waste water amendable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory...

  13. A generic standard additions based method to determine endogenous analyte concentrations by immunoassays to overcome complex biological matrix interference.

    PubMed

    Pang, Susan; Cowen, Simon

    2017-12-13

    We describe a novel generic method to derive the unknown endogenous concentrations of analyte within complex biological matrices (e.g. serum or plasma) based upon the relationship between the immunoassay signal response of a biological test sample spiked with known analyte concentrations and the log transformed estimated total concentration. If the estimated total analyte concentration is correct, a portion of the sigmoid on a log-log plot is very close to linear, allowing the unknown endogenous concentration to be estimated using a numerical method. This approach obviates conventional relative quantification using an internal standard curve and need for calibrant diluent, and takes into account the individual matrix interference on the immunoassay by spiking the test sample itself. This technique is based on standard additions for chemical analytes. Unknown endogenous analyte concentrations within even 2-fold diluted human plasma may be determined reliably using as few as four reaction wells.

  14. 40 CFR 417.191 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... methylene blue active substances amenable to measurement by the method described in “Methods for Chemical Analysis of Water and Wastes,” 1971, Environmental Protection Agency, Analytical Quality Control Laboratory...

  15. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2014-06-03

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  16. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2015-09-29

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  17. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J; Kertesz, Vilmos; Ovchinnikova, Olga S

    2013-08-27

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  18. High Throughput Determination of Tetramine in Drinking ...

    EPA Pesticide Factsheets

    Report The sampling and analytical procedure (SAP) presented herein, describes a method for the high throughput determination of tetramethylene disulfotetramine in drinking water by solid phase extraction and isotope dilution gas chromatography/mass spectrometry. This method, which will be included in the SAM, is expected to provide the Water Laboratory Alliance, as part of EPA’s Environmental Response Laboratory Network, with a more reliable and faster means of analyte collection and measurement.

  19. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of selected carbamate pesticides in water by high-performance liquid chromatography

    USGS Publications Warehouse

    Werner, S.L.; Johnson, S.M.

    1994-01-01

    As part of its primary responsibility concerning water as a national resource, the U.S. Geological Survey collects and analyzes samples of ground water and surface water to determine water quality. This report describes the method used since June 1987 to determine selected total-recoverable carbamate pesticides present in water samples. High- performance liquid chromatography is used to separate N-methyl carbamates, N-methyl carbamoyloximes, and an N-phenyl carbamate which have been extracted from water and concentrated in dichloromethane. Analytes, surrogate compounds, and reference compounds are eluted from the analytical column within 25 minutes. Two modes of analyte detection are used: (1) a photodiode-array detector measures and records ultraviolet-absorbance profiles, and (2) a fluorescence detector measures and records fluorescence from an analyte derivative produced when analyte hydrolysis is combined with chemical derivatization. Analytes are identified and confirmed in a three-stage process by use of chromatographic retention time, ultraviolet (UV) spectral comparison, and derivatization/fluorescence detection. Quantitative results are based on the integration of single-wavelength UV-absorbance chromatograms and on comparison with calibration curves derived from external analyte standards that are run with samples as part of an instrumental analytical sequence. Estimated method detection limits vary for each analyte, depending on the sample matrix conditions, and range from 0.5 microgram per liter to as low as 0.01 microgram per liter. Reporting levels for all analytes have been set at 0.5 microgram per liter for this method. Corrections on the basis of percentage recoveries of analytes spiked into distilled water are not applied to values calculated for analyte concentration in samples. These values for analyte concentrations instead indicate the quantities recovered by the method from a particular sample matrix.

  20. Ion mobility analysis of lipoproteins

    DOEpatents

    Benner, W Henry [Danville, CA; Krauss, Ronald M [Berkeley, CA; Blanche, Patricia J [Berkeley, CA

    2007-08-21

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  1. Aerosol preparation of intact lipoproteins

    DOEpatents

    Benner, W Henry [Danville, CA; Krauss, Ronald M [Berkeley, CA; Blanche, Patricia J [Berkeley, CA

    2012-01-17

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  2. Direct current electrical potential measurement of the growth of small cracks

    NASA Technical Reports Server (NTRS)

    Gangloff, Richard P.; Slavik, Donald C.; Piascik, Robert S.; Van Stone, Robert H.

    1992-01-01

    The analytical and experimental aspects of the direct-current electrical potential difference (dcEPD) method for continuous monitoring of the growth kinetics of short (50 to 500 microns) fatigue cracks are reviewed, and successful applications of the deEPD method to study fatigue crack propagation in a variety of metallic alloys exposed to various environments are described. Particular attention is given to the principle of the dcEPD method, the analytical electrical potential calibration relationships, and the experimental procedures and equipment.

  3. Analyzing chromatographic data using multilevel modeling.

    PubMed

    Wiczling, Paweł

    2018-06-01

    It is relatively easy to collect chromatographic measurements for a large number of analytes, especially with gradient chromatographic methods coupled with mass spectrometry detection. Such data often have a hierarchical or clustered structure. For example, analytes with similar hydrophobicity and dissociation constant tend to be more alike in their retention than a randomly chosen set of analytes. Multilevel models recognize the existence of such data structures by assigning a model for each parameter, with its parameters also estimated from data. In this work, a multilevel model is proposed to describe retention time data obtained from a series of wide linear organic modifier gradients of different gradient duration and different mobile phase pH for a large set of acids and bases. The multilevel model consists of (1) the same deterministic equation describing the relationship between retention time and analyte-specific and instrument-specific parameters, (2) covariance relationships relating various physicochemical properties of the analyte to chromatographically specific parameters through quantitative structure-retention relationship based equations, and (3) stochastic components of intra-analyte and interanalyte variability. The model was implemented in Stan, which provides full Bayesian inference for continuous-variable models through Markov chain Monte Carlo methods. Graphical abstract Relationships between log k and MeOH content for acidic, basic, and neutral compounds with different log P. CI credible interval, PSA polar surface area.

  4. A Field Study Program in Analytical Chemistry for College Seniors.

    ERIC Educational Resources Information Center

    Langhus, D. L.; Flinchbaugh, D. A.

    1986-01-01

    Describes an elective field study program at Moravian College (Pennsylvania) in which seniors in analytical chemistry obtain first-hand experience at Bethlehem Steel Corporation. Discusses the program's planning phase, some method development projects done by students, experiences received in laboratory operations, and the evaluation of student…

  5. Internal Standards: A Source of Analytical Bias For Volatile Organic Analyte Determinations

    EPA Science Inventory

    The use of internal standards in the determination of volatile organic compounds as described in SW-846 Method 8260C introduces a potential for bias in results once the internal standards (ISTDs) are added to a sample for analysis. The bias is relative to the dissimilarity betw...

  6. 21 CFR 165.110 - Bottled water.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., when a composite of analytical units of equal volume from a sample is examined by the method described...)(A) Bottled water shall, when a composite of analytical units of equal volume from a sample is..., and Cosmetic Act, the Food and Drug Administration has determined that bottled water, when a composite...

  7. Dried blood spot specimen quality and validation of a new pre-analytical processing method for qualitative HIV-1 PCR, KwaZulu-Natal, South Africa

    PubMed Central

    Parboosing, Raveen; Siyaca, Ntombizandile; Moodley, Pravikrishnen

    2016-01-01

    Background Poor quality dried blood spot (DBS) specimens are usually rejected by virology laboratories, affecting early infant diagnosis of HIV. The practice of combining two incompletely-filled DBS in one specimen preparation tube during pre-analytical specimen processing (i.e., the two-spot method) has been implemented to reduce the number of specimens being rejected for insufficient volume. Objectives This study analysed laboratory data to describe the quality of DBS specimens and the use of the two-spot method over a one-year period, then validated the two-spot method against the standard (one-spot) method. Methods Data on HIV-1 PCR test requests submitted in 2014 to the Department of Virology at Inkosi Albert Luthuli Central Hospital in KwaZulu-Natal province, South Africa were analysed to describe reasons for specimen rejection, as well as results of the two-spot method. The accuracy, lower limit of detection and precision of the two-spot method were assessed. Results Of the 88 481 specimens received, 3.7% were rejected for pre-analytical problems. Of those, 48.9% were rejected as a result of insufficient specimen volume. Two health facilities had significantly more specimen rejections than other facilities. The two-spot method prevented 10 504 specimen rejections. The Pearson correlation coefficient comparing the standard to the two-spot method was 0.997. Conclusions The two-spot method was comparable with the standard method of pre-analytical specimen processing. Two health facilities were identified for targeted retraining on specimen quality. The two-spot method of DBS specimen processing can be used as an adjunct to retraining, to reduce the number of specimens rejected and improve linkage to care. PMID:28879108

  8. New methods for accelerating the convergence of molecular electronic integrals over exponential type orbitals

    NASA Astrophysics Data System (ADS)

    Safouhi, Hassan; Hoggan, Philip

    2003-01-01

    This review on molecular integrals for large electronic systems (MILES) places the problem of analytical integration over exponential-type orbitals (ETOs) in a historical context. After reference to the pioneering work, particularly by Barnett, Shavitt and Yoshimine, it focuses on recent progress towards rapid and accurate analytic solutions of MILES over ETOs. Software such as the hydrogenlike wavefunction package Alchemy by Yoshimine and collaborators is described. The review focuses on convergence acceleration of these highly oscillatory integrals and in particular it highlights suitable nonlinear transformations. Work by Levin and Sidi is described and applied to MILES. A step by step description of progress in the use of nonlinear transformation methods to obtain efficient codes is provided. The recent approach developed by Safouhi is also presented. The current state of the art in this field is summarized to show that ab initio analytical work over ETOs is now a viable option.

  9. Dried blood spot specimen quality and validation of a new pre-analytical processing method for qualitative HIV-1 PCR, KwaZulu-Natal, South Africa.

    PubMed

    Govender, Kerusha; Parboosing, Raveen; Siyaca, Ntombizandile; Moodley, Pravikrishnen

    2016-01-01

    Poor quality dried blood spot (DBS) specimens are usually rejected by virology laboratories, affecting early infant diagnosis of HIV. The practice of combining two incompletely-filled DBS in one specimen preparation tube during pre-analytical specimen processing (i.e., the two-spot method) has been implemented to reduce the number of specimens being rejected for insufficient volume. This study analysed laboratory data to describe the quality of DBS specimens and the use of the two-spot method over a one-year period, then validated the two-spot method against the standard (one-spot) method. Data on HIV-1 PCR test requests submitted in 2014 to the Department of Virology at Inkosi Albert Luthuli Central Hospital in KwaZulu-Natal province, South Africa were analysed to describe reasons for specimen rejection, as well as results of the two-spot method. The accuracy, lower limit of detection and precision of the two-spot method were assessed. Of the 88 481 specimens received, 3.7% were rejected for pre-analytical problems. Of those, 48.9% were rejected as a result of insufficient specimen volume. Two health facilities had significantly more specimen rejections than other facilities. The two-spot method prevented 10 504 specimen rejections. The Pearson correlation coefficient comparing the standard to the two-spot method was 0.997. The two-spot method was comparable with the standard method of pre-analytical specimen processing. Two health facilities were identified for targeted retraining on specimen quality. The two-spot method of DBS specimen processing can be used as an adjunct to retraining, to reduce the number of specimens rejected and improve linkage to care.

  10. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  11. Analytic modeling of aerosol size distributions

    NASA Technical Reports Server (NTRS)

    Deepack, A.; Box, G. P.

    1979-01-01

    Mathematical functions commonly used for representing aerosol size distributions are studied parametrically. Methods for obtaining best fit estimates of the parameters are described. A catalog of graphical plots depicting the parametric behavior of the functions is presented along with procedures for obtaining analytical representations of size distribution data by visual matching of the data with one of the plots. Examples of fitting the same data with equal accuracy by more than one analytic model are also given.

  12. Method of assessing a lipid-related health risk based on ion mobility analysis of lipoproteins

    DOEpatents

    Benner, W. Henry; Krauss, Ronald M.; Blanche, Patricia J.

    2010-12-14

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  13. APPLICATION OF THE ANALYTIC HIERARCHY PROCESS TO COMPARE ALTERNATIVES FOR THE LONG-TERM MANAGEMENT OF SURPLUS MERCURY

    EPA Science Inventory

    This paper describes a systematic method for comparing options for the long-term management of surplus elemental mercury in the U.S., using the Analytic Hierarchy Process (AHP) as embodied in commercially available Expert Choice software. A limited scope multi-criteria decision-a...

  14. Dynamics and Control of Flexible Space Vehicles

    NASA Technical Reports Server (NTRS)

    Likins, P. W.

    1970-01-01

    The purpose of this report is twofold: (1) to survey the established analytic procedures for the simulation of controlled flexible space vehicles, and (2) to develop in detail methods that employ a combination of discrete and distributed ("modal") coordinates, i.e., the hybrid-coordinate methods. Analytic procedures are described in three categories: (1) discrete-coordinate methods, (2) hybrid-coordinate methods, and (3) vehicle normal-coordinate methods. Each of these approaches is described and analyzed for its advantages and disadvantages, and each is found to have an area of applicability. The hybrid-coordinate method combines the efficiency of the vehicle normal-coordinate method with the versatility of the discrete-coordinate method, and appears to have the widest range of practical application. The results in this report have practical utility in two areas: (1) complex digital computer simulation of flexible space vehicles of arbitrary configuration subject to realistic control laws, and (2) preliminary control system design based on transfer functions for linearized models of dynamics and control laws.

  15. Determining the risk of cardiovascular disease using ion mobility of lipoproteins

    DOEpatents

    Benner, W. Henry; Krauss, Ronald M.; Blanche, Patricia J.

    2010-05-11

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  16. Frequency-independent radiation modes of interior sound radiation: An analytical study

    NASA Astrophysics Data System (ADS)

    Hesse, C.; Vivar Perez, J. M.; Sinapius, M.

    2017-03-01

    Global active control methods of sound radiation into acoustic cavities necessitate the formulation of the interior sound field in terms of the surrounding structural velocity. This paper proposes an efficient approach to do this by presenting an analytical method to describe the radiation modes of interior sound radiation. The method requires no knowledge of the structural modal properties, which are often difficult to obtain in control applications. The procedure is exemplified for two generic systems of fluid-structure interaction, namely a rectangular plate coupled to a cuboid cavity and a hollow cylinder with the fluid in its enclosed cavity. The radiation modes are described as a subset of the acoustic eigenvectors on the structural-acoustic interface. For the two studied systems, they are therefore independent of frequency.

  17. Analytical Method Used to Calculate Pile Foundations with the Widening Up on a Horizontal Static Impact

    NASA Astrophysics Data System (ADS)

    Kupchikova, N. V.; Kurbatskiy, E. N.

    2017-11-01

    This paper presents a methodology for the analytical research solutions for the work pile foundations with surface broadening and inclined side faces in the ground array, based on the properties of Fourier transform of finite functions. The comparative analysis of the calculation results using the suggested method for prismatic piles, piles with surface broadening prismatic with precast piles and end walls with precast wedges on the surface is described.

  18. Solving the Helmholtz equation in conformal mapped ARROW structures using homotopy perturbation method.

    PubMed

    Reck, Kasper; Thomsen, Erik V; Hansen, Ole

    2011-01-31

    The scalar wave equation, or Helmholtz equation, describes within a certain approximation the electromagnetic field distribution in a given system. In this paper we show how to solve the Helmholtz equation in complex geometries using conformal mapping and the homotopy perturbation method. The solution of the mapped Helmholtz equation is found by solving an infinite series of Poisson equations using two dimensional Fourier series. The solution is entirely based on analytical expressions and is not mesh dependent. The analytical results are compared to a numerical (finite element method) solution.

  19. Validation of Ion Chromatographic Method for Determination of Standard Inorganic Anions in Treated and Untreated Drinking Water

    NASA Astrophysics Data System (ADS)

    Ivanova, V.; Surleva, A.; Koleva, B.

    2018-06-01

    An ion chromatographic method for determination of fluoride, chloride, nitrate and sulphate in untreated and treated drinking waters was described. An automated 850 IC Professional, Metrohm system equipped with conductivity detector and Metrosep A Supp 7-250 (250 x 4 mm) column was used. The validation of the method was performed for simultaneous determination of all studied analytes and the results have showed that the validated method fits the requirements of the current water legislation. The main analytical characteristics were estimated for each of studied analytes: limits of detection, limits of quantification, working and linear ranges, repeatability and intermediate precision, recovery. The trueness of the method was estimated by analysis of certified reference material for soft drinking water. Recovery test was performed on spiked drinking water samples. An uncertainty was estimated. The method was applied for analysis of drinking waters before and after chlorination.

  20. System and method for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J; Kertesz, Vilmos

    2014-01-28

    A system and method for laser desorption of an analyte from a specimen and capturing of the analyte in a suspended solvent to form a testing solution are described. The method can include providing a specimen supported by a desorption region of a specimen stage and desorbing an analyte from a target site of the specimen with a laser beam centered at a radiation wavelength (.lamda.). The desorption region is transparent to the radiation wavelength (.lamda.) and the sampling probe and a laser source emitting the laser beam are on opposite sides of a primary surface of the specimen stage. The system can also be arranged where the laser source and the sampling probe are on the same side of a primary surface of the specimen stage. The testing solution can then be analyzed using an analytical instrument or undergo further processing.

  1. Meromorphic solutions of recurrence relations and DRA method for multicomponent master integrals

    NASA Astrophysics Data System (ADS)

    Lee, Roman N.; Mingulov, Kirill T.

    2018-04-01

    We formulate a method to find the meromorphic solutions of higher-order recurrence relations in the form of the sum over poles with coefficients defined recursively. Several explicit examples of the application of this technique are given. The main advantage of the described approach is that the analytical properties of the solutions are very clear (the position of poles is explicit, the behavior at infinity can be easily determined). These are exactly the properties that are required for the application of the multiloop calculation method based on dimensional recurrence relations and analyticity (the DRA method).

  2. [Automated analyzer of enzyme immunoassay].

    PubMed

    Osawa, S

    1995-09-01

    Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.

  3. Potassium sodium chloride integrated microconduits in a potentiometric analytical system.

    PubMed

    Hongbo, C; Junyan, S

    1991-09-01

    The preparation and application of a K(+), Na(+) and Cl(-) integrated microconduit potentiometric analytical system with tubular ion-selective electrodes (ISEs), microvalve, chemfold, electrostatic and pulse inhibitors is described. Electrochemical characteristics of the tubular ISEs and integrated microconduit FIA-ISEs were studied. The contents of K(+), Na(+) and Cl(-) in soil, water and serum were determined with the device. The analytical results agreed well with those obtained by flame photometric and silver nitrate volumetric methods.

  4. Approaching near real-time biosensing: microfluidic microsphere based biosensor for real-time analyte detection.

    PubMed

    Cohen, Noa; Sabhachandani, Pooja; Golberg, Alexander; Konry, Tania

    2015-04-15

    In this study we describe a simple lab-on-a-chip (LOC) biosensor approach utilizing well mixed microfluidic device and a microsphere-based assay capable of performing near real-time diagnostics of clinically relevant analytes such cytokines and antibodies. We were able to overcome the adsorption kinetics reaction rate-limiting mechanism, which is diffusion-controlled in standard immunoassays, by introducing the microsphere-based assay into well-mixed yet simple microfluidic device with turbulent flow profiles in the reaction regions. The integrated microsphere-based LOC device performs dynamic detection of the analyte in minimal amount of biological specimen by continuously sampling micro-liter volumes of sample per minute to detect dynamic changes in target analyte concentration. Furthermore we developed a mathematical model for the well-mixed reaction to describe the near real time detection mechanism observed in the developed LOC method. To demonstrate the specificity and sensitivity of the developed real time monitoring LOC approach, we applied the device for clinically relevant analytes: Tumor Necrosis Factor (TNF)-α cytokine and its clinically used inhibitor, anti-TNF-α antibody. Based on the reported results herein, the developed LOC device provides continuous sensitive and specific near real-time monitoring method for analytes such as cytokines and antibodies, reduces reagent volumes by nearly three orders of magnitude as well as eliminates the washing steps required by standard immunoassays. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. [Construction of NIRS-based process analytical system for production of salvianolic acid for injection and relative discussion].

    PubMed

    Zhang, Lei; Yue, Hong-Shui; Ju, Ai-Chun; Ye, Zheng-Liang

    2016-10-01

    Currently, near infrared spectroscopy (NIRS) has been considered as an efficient tool for achieving process analytical technology(PAT) in the manufacture of traditional Chinese medicine (TCM) products. In this article, the NIRS based process analytical system for the production of salvianolic acid for injection was introduced. The design of the process analytical system was described in detail, including the selection of monitored processes and testing mode, and potential risks that should be avoided. Moreover, the development of relative technologies was also presented, which contained the establishment of the monitoring methods for the elution of polyamide resin and macroporous resin chromatography processes, as well as the rapid analysis method for finished products. Based on author's experience of research and work, several issues in the application of NIRS to the process monitoring and control in TCM production were then raised, and some potential solutions were also discussed. The issues include building the technical team for process analytical system, the design of the process analytical system in the manufacture of TCM products, standardization of the NIRS-based analytical methods, and improving the management of process analytical system. Finally, the prospect for the application of NIRS in the TCM industry was put forward. Copyright© by the Chinese Pharmaceutical Association.

  6. Approximate analytic method for high-apogee twelve-hour orbits of artificial Earth's satellites

    NASA Astrophysics Data System (ADS)

    Vashkovyaka, M. A.; Zaslavskii, G. S.

    2016-09-01

    We propose an approach to the study of the evolution of high-apogee twelve-hour orbits of artificial Earth's satellites. We describe parameters of the motion model used for the artificial Earth's satellite such that the principal gravitational perturbations of the Moon and Sun, nonsphericity of the Earth, and perturbations from the light pressure force are approximately taken into account. To solve the system of averaged equations describing the evolution of the orbit parameters of an artificial satellite, we use both numeric and analytic methods. To select initial parameters of the twelve-hour orbit, we assume that the path of the satellite along the surface of the Earth is stable. Results obtained by the analytic method and by the numerical integration of the evolving system are compared. For intervals of several years, we obtain estimates of oscillation periods and amplitudes for orbital elements. To verify the results and estimate the precision of the method, we use the numerical integration of rigorous (not averaged) equations of motion of the artificial satellite: they take into account forces acting on the satellite substantially more completely and precisely. The described method can be applied not only to the investigation of orbit evolutions of artificial satellites of the Earth; it can be applied to the investigation of the orbit evolution for other planets of the Solar system provided that the corresponding research problem will arise in the future and the considered special class of resonance orbits of satellites will be used for that purpose.

  7. A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.

    PubMed

    Yang, Harry; Zhang, Jianchun

    2015-01-01

    The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current methods. Analytical methods are often used to ensure safety, efficacy, and quality of medicinal products. According to government regulations and regulatory guidelines, these methods need to be validated through well-designed studies to minimize the risk of accepting unsuitable methods. This article describes a novel statistical test for analytical method validation, which provides better protection for the risk of accepting unsuitable analytical methods. © PDA, Inc. 2015.

  8. Linguistics and the Study of Literature. Linguistics in the Undergraduate Curriculum, Appendix 4-D.

    ERIC Educational Resources Information Center

    Steward, Ann Harleman

    Linguistics gives the student of literature an analytical tool whose sole purpose is to describe faithfully the workings of language. It provides a theoretical framework, an analytical method, and a vocabulary for communicating its insights--all designed to serve concerns other than literary interpretation and evaluation, but all useful for…

  9. Hasse diagram as a green analytical metrics tool: ranking of methods for benzo[a]pyrene determination in sediments.

    PubMed

    Bigus, Paulina; Tsakovski, Stefan; Simeonov, Vasil; Namieśnik, Jacek; Tobiszewski, Marek

    2016-05-01

    This study presents an application of the Hasse diagram technique (HDT) as the assessment tool to select the most appropriate analytical procedures according to their greenness or the best analytical performance. The dataset consists of analytical procedures for benzo[a]pyrene determination in sediment samples, which were described by 11 variables concerning their greenness and analytical performance. Two analyses with the HDT were performed-the first one with metrological variables and the second one with "green" variables as input data. Both HDT analyses ranked different analytical procedures as the most valuable, suggesting that green analytical chemistry is not in accordance with metrology when benzo[a]pyrene in sediment samples is determined. The HDT can be used as a good decision support tool to choose the proper analytical procedure concerning green analytical chemistry principles and analytical performance merits.

  10. EPA (ENVIRONMENTAL PROTECTION AGENCY) METHOD STUDY 28, PCB'S (POLYCHLORINATED BIPHENYLS) IN OIL

    EPA Science Inventory

    This report describes the experimental design and the results of the validation study for two analytical methods to detect polychlorinated byphenyls in oil. The methods analyzed for four PCB Aroclors (1016, 1242, 1254, and 1260), 2-chlorobiphenyl, and decachlorobiphenyl. The firs...

  11. Interlaboratory comparability, bias, and precision for four laboratories measuring constituents in precipitation, November 1982-August 1983

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Malo, B.A.

    1985-01-01

    Four laboratories were evaluated in their analysis of identical natural and simulated precipitation water samples. Interlaboratory comparability was evaluated using analysis of variance coupled with Duncan 's multiple range test, and linear-regression models describing the relations between individual laboratory analytical results for natural precipitation samples. Results of the statistical analyses indicate that certain pairs of laboratories produce different results when analyzing identical samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple range test on data produced by the laboratories from the analysis of identical simulated precipitation samples. Bias for a given analyte produced by a single laboratory has been indicated when the laboratory mean for that analyte is shown to be significantly different from the mean for the most-probable analyte concentrations in the simulated precipitation samples. Ion-chromatographic methods for the determination of chloride, nitrate, and sulfate have been compared with the colorimetric methods that were also in use during the study period. Comparisons were made using analysis of variance coupled with Duncan 's multiple range test for means produced by the two methods. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Analyte estimated precisions have been compared using F-tests and differences in analyte precisions for laboratory pairs have been reported. (USGS)

  12. Analytical and numerical analysis of the slope of von Mises planar trusses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalina, M.; Frantík, P.

    2016-06-08

    In the present paper, there are presented post-critical stress states which will occur at loading by vertical shift of the top joint in the direction downwards. The formation of certain stress states depends on the size of the angle formed by a straight beam of the von Mises planar truss with horizontal plane. Numerical and analytical methods and their problems with finding the angle were described. The numerical solution applies the method of searching for a minimum of potential energy.

  13. Analytical Solution of a Generalized Hirota-Satsuma Equation

    NASA Astrophysics Data System (ADS)

    Kassem, M.; Mabrouk, S.; Abd-el-Malek, M.

    A modified version of generalized Hirota-Satsuma is here solved using a two parameter group transformation method. This problem in three dimensions was reduced by Estevez [1] to a two dimensional one through a Lie transformation method and left unsolved. In the present paper, through application of symmetry transformation the Lax pair has been reduced to a system of ordinary equations. Three transformations cases are investigated. The obtained analytical solutions are plotted and show a profile proper to deflagration processes, well described by Degasperis-Procesi equation.

  14. Novel asymmetric representation method for solving the higher-order Ginzburg-Landau equation

    PubMed Central

    Wong, Pring; Pang, Lihui; Wu, Ye; Lei, Ming; Liu, Wenjun

    2016-01-01

    In ultrafast optics, optical pulses are generated to be of shorter pulse duration, which has enormous significance to industrial applications and scientific research. The ultrashort pulse evolution in fiber lasers can be described by the higher-order Ginzburg-Landau (GL) equation. However, analytic soliton solutions for this equation have not been obtained by use of existing methods. In this paper, a novel method is proposed to deal with this equation. The analytic soliton solution is obtained for the first time, and is proved to be stable against amplitude perturbations. Through the split-step Fourier method, the bright soliton solution is studied numerically. The analytic results here may extend the integrable methods, and could be used to study soliton dynamics for some equations in other disciplines. It may also provide the other way to obtain two-soliton solutions for higher-order GL equations. PMID:27086841

  15. Detection of molecular interactions

    DOEpatents

    Groves, John T [Berkeley, CA; Baksh, Michael M [Fremont, CA; Jaros, Michal [Brno, CH

    2012-02-14

    A method and assay are described for measuring the interaction between a ligand and an analyte. The assay can include a suspension of colloidal particles that are associated with a ligand of interest. The colloidal particles are maintained in the suspension at or near a phase transition state from a condensed phase to a dispersed phase. An analyte to be tested is then added to the suspension. If the analyte binds to the ligand, a phase change occurs to indicate that the binding was successful.

  16. [Problems of food authenticity].

    PubMed

    Czerwiecki, Ludwik

    2004-01-01

    In this review the several data concerning food authenticity were presented. Typical examples of food adulteration were described. The most known are adulteration of vegetable and fruit products, adulteration of wine, honeys, olive oil etc. The modern analytical techniques for detection of food adulteration were discussed. Among physicochemical methods isotopic techniques (SCIRA, IRMS, SNIF-NMR) were cited. The main spectral methods are: IACPAES, PyMs, FTIR, NIR. The chromatographic techniques (GC, HPLC, HPAEC, HPTLC) with several kinds of detectors were described and the ELISA and PCR techniques are mentioned, too. The role of chemometrics as a way of several analytical data processing was highlighted. It was pointed out at the necessity of more rigorous control of food to support of all activity in area of fight with fraud in food industry.

  17. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    PubMed

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  18. Method validation using weighted linear regression models for quantification of UV filters in water samples.

    PubMed

    da Silva, Claudia Pereira; Emídio, Elissandro Soares; de Marchi, Mary Rosa Rodrigues

    2015-01-01

    This paper describes the validation of a method consisting of solid-phase extraction followed by gas chromatography-tandem mass spectrometry for the analysis of the ultraviolet (UV) filters benzophenone-3, ethylhexyl salicylate, ethylhexyl methoxycinnamate and octocrylene. The method validation criteria included evaluation of selectivity, analytical curve, trueness, precision, limits of detection and limits of quantification. The non-weighted linear regression model has traditionally been used for calibration, but it is not necessarily the optimal model in all cases. Because the assumption of homoscedasticity was not met for the analytical data in this work, a weighted least squares linear regression was used for the calibration method. The evaluated analytical parameters were satisfactory for the analytes and showed recoveries at four fortification levels between 62% and 107%, with relative standard deviations less than 14%. The detection limits ranged from 7.6 to 24.1 ng L(-1). The proposed method was used to determine the amount of UV filters in water samples from water treatment plants in Araraquara and Jau in São Paulo, Brazil. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. A laser interferometer for measuring skin friction in three-dimensional flows

    NASA Technical Reports Server (NTRS)

    Monson, D. J.

    1983-01-01

    A new, nonintrusive method is described for measuring skin friction in three-dimensional flows with unknown direction. The method uses a laser interferometer to measure the changing slope of a thin oil film applied to a surface experiencing shear stress. The details of the method are described, and skin friction measurements taken in a swirling three-dimensional boundary-layer flow are presented. Comparisons between analytical results and experimental values from the laser interferometer method and from a bidirectional surface-fence gauge are made.

  20. Introductory Guide to the Statistics of Molecular Genetics

    ERIC Educational Resources Information Center

    Eley, Thalia C.; Rijsdijk, Fruhling

    2005-01-01

    Background: This introductory guide presents the main two analytical approaches used by molecular geneticists: linkage and association. Methods: Traditional linkage and association methods are described, along with more recent advances in methodologies such as those using a variance components approach. Results: New methods are being developed all…

  1. Development of a reference material for routine performance monitoring of methods measuring polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and dioxin-like polychlorinated biphenyls.

    PubMed

    Selliah, S S; Cussion, S; MacPherson, K A; Reiner, E J; Toner, D

    2001-06-01

    Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.

  2. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Moderate-Use Pesticides and Selected Degradates in Water by C-18 Solid-Phase Extraction and Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Sandstrom, Mark W.; Stroppel, Max E.; Foreman, William T.; Schroeder, Michael P.

    2001-01-01

    A method for the isolation and analysis of 21 parent pesticides and 20 pesticide degradates in natural-water samples is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase-extraction columns that contain octadecyl-bonded porous silica to extract the analytes. The columns are dried by using nitrogen gas, and adsorbed analytes are eluted with ethyl acetate. Extracted analytes are determined by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 2 micrograms per liter (?g/L) for most analytes. Single-operator method detection limits in reagent-water samples range from 0.00 1 to 0.057 ?g/L. Validation data also are presented for 14 parent pesticides and 20 degradates that were determined to have greater bias or variability, or shorter holding times than the other compounds. The estimated maximum holding time for analytes in pesticide-grade water before extraction was 4 days. The estimated maximum holding time for analytes after extraction on the dry solid-phase-extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time. The method complements existing U.S. Geological Survey Method O-1126-95 (NWQL Schedules 2001 and 2010) by using identical sample preparation and comparable instrument analytical conditions so that sample extracts can be analyzed by either method to expand the range of analytes determined from one water sample.

  3. Analytic regularization of uniform cubic B-spline deformation fields.

    PubMed

    Shackleford, James A; Yang, Qi; Lourenço, Ana M; Shusharina, Nadya; Kandasamy, Nagarajan; Sharp, Gregory C

    2012-01-01

    Image registration is inherently ill-posed, and lacks a unique solution. In the context of medical applications, it is desirable to avoid solutions that describe physically unsound deformations within the patient anatomy. Among the accepted methods of regularizing non-rigid image registration to provide solutions applicable to medical practice is the penalty of thin-plate bending energy. In this paper, we develop an exact, analytic method for computing the bending energy of a three-dimensional B-spline deformation field as a quadratic matrix operation on the spline coefficient values. Results presented on ten thoracic case studies indicate the analytic solution is between 61-1371x faster than a numerical central differencing solution.

  4. Regional geochemical maps of the Tonopah 1 degree by 2 degrees Quadrangle, Nevada, based on samples of stream sediment and nonmagnetic heavy-mineral concentrate

    USGS Publications Warehouse

    Nash, J.T.; Siems, D.F.

    1988-01-01

    The geochemical maps in this report are based on analytical results reported by Fairfield and others (1985), Hill and others (1986), and Siems and others (1986). These reports also describe the sample preparation and analytical methods and provide information on the location of the sample sites.

  5. Multipass optical device and process for gas and analyte determination

    DOEpatents

    Bernacki, Bruce E [Kennewick, WA

    2011-01-25

    A torus multipass optical device and method are described that provide for trace level determination of gases and gas-phase analytes. The torus device includes an optical cavity defined by at least one ring mirror. The mirror delivers optical power in at least a radial and axial direction and propagates light in a multipass optical path of a predefined path length.

  6. [Enzymatic analysis of the quality of foodstuffs].

    PubMed

    Kolesnov, A Iu

    1997-01-01

    Enzymatic analysis is an independent and separate branch of enzymology and analytical chemistry. It has become one of the most important methodologies used in food analysis. Enzymatic analysis allows the quick, reliable determination of many food ingredients. Often these contents cannot be determined by conventional methods, or if methods are available, they are determined only with limited accuracy. Today, methods of enzymatic analysis are being increasingly used in the investigation of foodstuffs. Enzymatic measurement techniques are used in industry, scientific and food inspection laboratories for quality analysis. This article describes the requirements of an optimal analytical method: specificity, sample preparation, assay performance, precision, sensitivity, time requirement, analysis cost, safety of reagents.

  7. Two-dimensional analytic weighting functions for limb scattering

    NASA Astrophysics Data System (ADS)

    Zawada, D. J.; Bourassa, A. E.; Degenstein, D. A.

    2017-10-01

    Through the inversion of limb scatter measurements it is possible to obtain vertical profiles of trace species in the atmosphere. Many of these inversion methods require what is often referred to as weighting functions, or derivatives of the radiance with respect to concentrations of trace species in the atmosphere. Several radiative transfer models have implemented analytic methods to calculate weighting functions, alleviating the computational burden of traditional numerical perturbation methods. Here we describe the implementation of analytic two-dimensional weighting functions, where derivatives are calculated relative to atmospheric constituents in a two-dimensional grid of altitude and angle along the line of sight direction, in the SASKTRAN-HR radiative transfer model. Two-dimensional weighting functions are required for two-dimensional inversions of limb scatter measurements. Examples are presented where the analytic two-dimensional weighting functions are calculated with an underlying one-dimensional atmosphere. It is shown that the analytic weighting functions are more accurate than ones calculated with a single scatter approximation, and are orders of magnitude faster than a typical perturbation method. Evidence is presented that weighting functions for stratospheric aerosols calculated under a single scatter approximation may not be suitable for use in retrieval algorithms under solar backscatter conditions.

  8. A Review of Analytical Methods for p-Coumaric Acid in Plant-Based Products, Beverages, and Biological Matrices.

    PubMed

    Ferreira, Paula Scanavez; Victorelli, Francesca Damiani; Fonseca-Santos, Bruno; Chorilli, Marlus

    2018-05-14

    p-Coumaric acid (p-CA), also known as 4-hydroxycinnamic acid, is a phenolic acid, which has been widely studied due to its beneficial effects against several diseases and its wide distribution in the plant kingdom. This phenolic compound can be found in the free form or conjugated with other molecules; therefore, its bioavailability and the pathways via which it is metabolized change according to its chemical structure. p-CA has potential pharmacological effects because it has high free radical scavenging, anti-inflammatory, antineoplastic, and antimicrobial activities, among other biological properties. It is therefore essential to choose the most appropriate and effective analytical method for qualitative and quantitative determination of p-CA in different matrices, such as plasma, urine, plant extracts, and drug delivery systems. The most-reported analytical method for this purpose is high-performance liquid chromatography, which is mostly coupled with some type of detectors, such as UV/Vis detector. However, other analytical techniques are also used to evaluate this compound. This review presents a summary of p-CA in terms of its chemical and pharmacokinetic properties, pharmacological effects, drug delivery systems, and the analytical methods described in the literature that are suitable for its quantification.

  9. ANALYSIS OF ALDEHYDES AND KETONES IN THE GAS PHASE

    EPA Science Inventory

    The development and testing of a 2,4-dinitrophenylhydrazine-acetonitrile (DNPH-ACN) method for the analysis of aldehydes and ketones in ambient air are described. A discussion of interferences, preparation of calibration standards, analytical testing, fluorescence methods and car...

  10. Analytical methods of the U.S. Geological Survey's New York District Water-Analysis Laboratory

    USGS Publications Warehouse

    Lawrence, Gregory B.; Lincoln, Tricia A.; Horan-Ross, Debra A.; Olson, Mark L.; Waldron, Laura A.

    1995-01-01

    The New York District of the U.S. Geological Survey (USGS) in Troy, N.Y., operates a water-analysis laboratory for USGS watershed-research projects in the Northeast that require analyses of precipitation and of dilute surface water and soil water for major ions; it also provides analyses of certain chemical constituents in soils and soil gas samples.This report presents the methods for chemical analyses of water samples, soil-water samples, and soil-gas samples collected in wateshed-research projects. The introduction describes the general materials and technicques for each method and explains the USGS quality-assurance program and data-management procedures; it also explains the use of cross reference to the three most commonly used methods manuals for analysis of dilute waters. The body of the report describes the analytical procedures for (1) solution analysis, (2) soil analysis, and (3) soil-gas analysis. The methods are presented in alphabetical order by constituent. The method for each constituent is preceded by (1) reference codes for pertinent sections of the three manuals mentioned above, (2) a list of the method's applications, and (3) a summary of the procedure. The methods section for each constitutent contains the following categories: instrumentation and equipment, sample preservation and storage, reagents and standards, analytical procedures, quality control, maintenance, interferences, safety considerations, and references. Sufficient information is presented for each method to allow the resulting data to be appropriately used in environmental investigations.

  11. RCRA Facility investigation report for Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Volume 5, Technical Memorandums 06-09A, 06-10A, and 06-12A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This report provides a detailed summary of the activities carried out to sample groundwater at Waste Area Grouping (WAG) 6. The analytical results for samples collected during Phase 1, Activity 2 of the WAG 6 Resource Conservation and Recovery Act Facility Investigation (RFI) are also presented. In addition, analytical results for Phase 1, activity sampling events for which data were not previously reported are included in this TM. A summary of the groundwater sampling activities of WAG 6, to date, are given in the Introduction. The Methodology section describes the sampling procedures and analytical parameters. Six attachments are included. Attachmentsmore » 1 and 2 provide analytical results for selected RFI groundwater samples and ORNL sampling event. Attachment 3 provides a summary of the contaminants detected in each well sampled for all sampling events conducted at WAG 6. Bechtel National Inc. (BNI)/IT Corporation Contract Laboratory (IT) RFI analytical methods and detection limits are given in Attachment 4. Attachment 5 provides the Oak Ridge National Laboratory (ORNL)/Analytical Chemistry Division (ACD) analytical methods and detection limits and Resource Conservation and Recovery Act (RCRA) quarterly compliance monitoring (1988--1989). Attachment 6 provides ORNL/ACD groundwater analytical methods and detection limits (for the 1990 RCRA semi-annual compliance monitoring).« less

  12. Analytical method for the fast time-domain reconstruction of fluorescent inclusions in vitro and in vivo.

    PubMed

    Han, Sung-Ho; Farshchi-Heydari, Salman; Hall, David J

    2010-01-20

    A novel time-domain optical method to reconstruct the relative concentration, lifetime, and depth of a fluorescent inclusion is described. We establish an analytical method for the estimations of these parameters for a localized fluorescent object directly from the simple evaluations of continuous wave intensity, exponential decay, and temporal position of the maximum of the fluorescence temporal point-spread function. Since the more complex full inversion process is not involved, this method permits a robust and fast processing in exploring the properties of a fluorescent inclusion. This method is confirmed by in vitro and in vivo experiments. Copyright 2010 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  13. Reliable determination of new lipid peroxidation compounds as potential early Alzheimer Disease biomarkers.

    PubMed

    García-Blanco, Ana; Peña-Bautista, Carmen; Oger, Camille; Vigor, Claire; Galano, Jean-Marie; Durand, Thierry; Martín-Ibáñez, Nuria; Baquero, Miguel; Vento, Máximo; Cháfer-Pericás, Consuelo

    2018-07-01

    Lipid peroxidation plays an important role in Alzheimer Disease, so corresponding metabolites found in urine samples could be potential biomarkers. The aim of this work is to develop a reliable ultra-performance liquid chromatography-tandem mass spectrometry analytical method to determine a new set of lipid peroxidation compounds in urine samples. Excellent sensitivity was achieved with limits of detection between 0.08 and 17 nmol L -1 , which renders this method suitable to monitor analytes concentrations in real samples. The method's precision was satisfactory with coefficients of variation around 5-17% (intra-day) and 8-19% (inter-day). The accuracy of the method was assessed by analysis of spiked urine samples obtaining recoveries between 70% and 120% for most of the analytes. The utility of the described method was tested by analyzing urine samples from patients early diagnosed with mild cognitive impairment or mild dementia Alzheimer Disease following the clinical standard criteria. As preliminary results, some analytes (17(RS)-10-epi-SC-Δ 15 -11-dihomo-IsoF, PGE 2 ) and total parameters (Neuroprostanes, Isoprostanes, Isofurans) show differences between the control and the clinical groups. So, these analytes could be potential early Alzheimer Disease biomarkers assessing the patients' pro-oxidant condition. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. A method for direct, semi-quantitative analysis of gas phase samples using gas chromatography-inductively coupled plasma-mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carter, Kimberly E; Gerdes, Kirk

    2013-07-01

    A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GCmore » sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3. This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.« less

  15. Development of Impurity Profiling Methods Using Modern Analytical Techniques.

    PubMed

    Ramachandra, Bondigalla

    2017-01-02

    This review gives a brief introduction about the process- and product-related impurities and emphasizes on the development of novel analytical methods for their determination. It describes the application of modern analytical techniques, particularly the ultra-performance liquid chromatography (UPLC), liquid chromatography-mass spectrometry (LC-MS), high-resolution mass spectrometry (HRMS), gas chromatography-mass spectrometry (GC-MS) and high-performance thin layer chromatography (HPTLC). In addition to that, the application of nuclear magnetic resonance (NMR) spectroscopy was also discussed for the characterization of impurities and degradation products. The significance of the quality, efficacy and safety of drug substances/products, including the source of impurities, kinds of impurities, adverse effects by the presence of impurities, quality control of impurities, necessity for the development of impurity profiling methods, identification of impurities and regulatory aspects has been discussed. Other important aspects that have been discussed are forced degradation studies and the development of stability indicating assay methods.

  16. Microchannel gel electrophoretic separation systems and methods for preparing and using

    DOEpatents

    Herr, Amy E; Singh, Anup K; Throckmorton, Daniel J

    2015-02-24

    A micro-analytical platform for performing electrophoresis-based immunoassays was developed by integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device. The microfluidic immunoassays are performed by gel electrophoretic separation and quantifying analyte concentration based upon conventional polyacrylamide gel electrophoresis (PAGE). To retain biological activity of proteins and maintain intact immune complexes, native PAGE conditions were employed. Both direct (non-competitive) and competitive immunoassay formats are demonstrated in microchips for detecting toxins and biomarkers (cytokines, c-reactive protein) in bodily fluids (serum, saliva, oral fluids). Further, a description of gradient gels fabrication is included, in an effort to describe methods we have developed for further optimization of on-chip PAGE immunoassays. The described chip-based PAGE immunoassay method enables immunoassays that are fast (minutes) and require very small amounts of sample (less than a few microliters). Use of microfabricated chips as a platform enables integration, parallel assays, automation and development of portable devices.

  17. Microchannel gel electrophoretic separation systems and methods for preparing and using

    DOEpatents

    Herr, Amy; Singh, Anup K; Throckmorton, Daniel J

    2013-09-03

    A micro-analytical platform for performing electrophoresis-based immunoassays was developed by integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device. The microfluidic immunoassays are performed by gel electrophoretic separation and quantifying analyte concentration based upon conventional polyacrylamide gel electrophoresis (PAGE). To retain biological activity of proteins and maintain intact immune complexes, native PAGE conditions were employed. Both direct (non-competitive) and competitive immunoassay formats are demonstrated in microchips for detecting toxins and biomarkers (cytokines, c-reactive protein) in bodily fluids (serum, saliva, oral fluids). Further, a description of gradient gels fabrication is included, in an effort to describe methods we have developed for further optimization of on-chip PAGE immunoassays. The described chip-based PAGE immunoassay method enables immunoassays that are fast (minutes) and require very small amounts of sample (less than a few microliters). Use of microfabricated chips as a platform enables integration, parallel assays, automation and development of portable devices.

  18. 40 CFR 408.121 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217. (c) The term seafood shall mean the raw material, including freshwater and saltwater...

  19. Hanford Environmental Analytical Methods (methods as of March 1990). Volume 2, Appendix A1-O and appendix A1-I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goheen, S.C.; McCulloch, M.; Daniel, J.L.

    1993-05-01

    Techniques in use at the Hanford Reservation as of March, 1990 for the analysis of liquids, organic wastes, soils, and sediments, are described. Limitations and applications of the techniques are included.

  20. Models of dyadic social interaction.

    PubMed Central

    Griffin, Dale; Gonzalez, Richard

    2003-01-01

    We discuss the logic of research designs for dyadic interaction and present statistical models with parameters that are tied to psychologically relevant constructs. Building on Karl Pearson's classic nineteenth-century statistical analysis of within-organism similarity, we describe several approaches to indexing dyadic interdependence and provide graphical methods for visualizing dyadic data. We also describe several statistical and conceptual solutions to the 'levels of analytic' problem in analysing dyadic data. These analytic strategies allow the researcher to examine and measure psychological questions of interdependence and social influence. We provide illustrative data from casually interacting and romantic dyads. PMID:12689382

  1. An analytical approach to γ-ray self-shielding effects for radioactive bodies encountered nuclear decommissioning scenarios.

    PubMed

    Gamage, K A A; Joyce, M J

    2011-10-01

    A novel analytical approach is described that accounts for self-shielding of γ radiation in decommissioning scenarios. The approach is developed with plutonium-239, cobalt-60 and caesium-137 as examples; stainless steel and concrete have been chosen as the media for cobalt-60 and caesium-137, respectively. The analytical methods have been compared MCNPX 2.6.0 simulations. A simple, linear correction factor relates the analytical results and the simulated estimates. This has the potential to greatly simplify the estimation of self-shielding effects in decommissioning activities. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Recent Transonic Flutter Investigations for Wings and External Stores

    DTIC Science & Technology

    1983-01-01

    and difficult method? In the early days of high-speed air- craft design . the aeroelastician realized that non -compressible aerodynamic theory and... experimental aeroelastic model program that would provide insight into the effects of Reynolds number and angle of attack on various airfoil designs regarding...investigation is carried out both experimentally and analytically. The analytic modelling will be described in a later section. The flutter calculations

  3. Experimental and analytical studies for the NASA carbon fiber risk assessment

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Various experimental and analytical studies performed for the NASA carbon fiber risk assessment program are described with emphasis on carbon fiber characteristics, sensitivity of electrical equipment and components to shorting or arcing by carbon fibers, attenuation effect of carbon fibers on aircraft landing aids, impact of carbon fibers on industrial facilities. A simple method of estimating damage from airborne carbon fibers is presented.

  4. Developing and Implementing Inquiry-Based, Water Quality Laboratory Experiments for High School Students to Explore Real Environmental Issues Using Analytical Chemistry

    ERIC Educational Resources Information Center

    Mandler, Daphna; Blonder, Ron; Yayon, Malka; Mamlok-Naaman, Rachel; Hofstein, Avi

    2014-01-01

    This paper describes the rationale and the implementation of five laboratory experiments; four of them, intended for high-school students, are inquiry-based activities that explore the quality of water. The context of water provides students with an opportunity to study the importance of analytical methods and how they influence our everyday…

  5. Laboratory analytical methods for the determination of the hydrocarbon status of soils (a review)

    NASA Astrophysics Data System (ADS)

    Pikovskii, Yu. I.; Korotkov, L. A.; Smirnova, M. A.; Kovach, R. G.

    2017-10-01

    Laboratory analytical methods suitable for the determination of the hydrocarbon status of soils (a specific soil characteristic involving information on the total content and qualitative features of soluble (bitumoid) carbonaceous substances and individual hydrocarbons (polycyclic aromatic hydrocarbons, alkanes, etc.) in bitumoid, as well as the composition and content of hydrocarbon gases) have been considered. Among different physicochemical methods of study, attention is focused on the methods suitable for the wide use. Luminescence-bituminological analysis, low-temperature spectrofluorimetry (Shpolskii spectroscopy), infrared (IR) spectroscopy, gas chromatography, chromatography-mass spectrometry, and some other methods have been characterized, as well as sample preparation features. Advantages and limitations of each of these methods are described; their efficiency, instrumental complexity, analysis duration, and accuracy are assessed.

  6. Interactions between butterfly-shaped pulses in the inhomogeneous media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wen-Jun; Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190; Huang, Long-Gang

    2014-10-15

    Pulse interactions affect pulse qualities during the propagation. Interactions between butterfly-shaped pulses are investigated to improve pulse qualities in the inhomogeneous media. In order to describe the interactions between butterfly-shaped pulses, analytic two-soliton solutions are derived. Based on those solutions, influences of corresponding parameters on pulse interactions are discussed. Methods to control the pulse interactions are suggested. - Highlights: • Interactions between butterfly-shaped pulses are investigated. • Methods to control the pulse interactions are suggested. • Analytic two-soliton solutions for butterfly-shaped pulses are derived.

  7. Quantitative detection of pathogens in centrifugal microfluidic disks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koh, Chung-Yan; Schaff, Ulrich Y.; Sommer, Gregory Jon

    A system and methods for detection of a nucleic acid including forming a plurality of nucleic acid detection complexes are described, each of the complexes including a nucleic acid analyte, a detection agent and a functionalized probe. The method further including binding the nucleic acid detection complexes to a plurality of functionalized particles in a fluid sample and separating the functionalized particles having the nucleic acid detection complexes bound thereto from the fluid sample using a density media. The nucleic acid analyte is detected by detecting the detection agent.

  8. Determination of stoichiometry and concentration of trace elements in thin BaxSr1-xTiO3 perovskite layers.

    PubMed

    Becker, J S; Boulyga, S F

    2001-07-01

    This paper describes an analytical procedure for determining the stoichiometry of BaxSr1-xTiO3 perovskite layers using inductively coupled plasma mass spectrometry (ICP-MS). The analytical results of mass spectrometry measurements are compared to those of X-ray fluorescence analysis (XRF). The performance and the limits of solid-state mass spectrometry analytical methods for the surface analysis of thin BaxSr1-xTiO3 perovskite layers sputtered neutral mass spectrometry (SNMS)--are investigated and discussed.

  9. Analytic Complexity and Challenges in Identifying Mixtures of Exposures Associated with Phenotypes in the Exposome Era.

    PubMed

    Patel, Chirag J

    2017-01-01

    Mixtures, or combinations and interactions between multiple environmental exposures, are hypothesized to be causally linked with disease and health-related phenotypes. Established and emerging molecular measurement technologies to assay the exposome , the comprehensive battery of exposures encountered from birth to death, promise a new way of identifying mixtures in disease in the epidemiological setting. In this opinion, we describe the analytic complexity and challenges in identifying mixtures associated with phenotype and disease. Existing and emerging machine-learning methods and data analytic approaches (e.g., "environment-wide association studies" [EWASs]), as well as large cohorts may enhance possibilities to identify mixtures of correlated exposures associated with phenotypes; however, the analytic complexity of identifying mixtures is immense. If the exposome concept is realized, new analytical methods and large sample sizes will be required to ascertain how mixtures are associated with disease. The author recommends documenting prevalent correlated exposures and replicated main effects prior to identifying mixtures.

  10. Reproducibility studies for experimental epitope detection in macrophages (EDIM).

    PubMed

    Japink, Dennis; Nap, Marius; Sosef, Meindert N; Nelemans, Patty J; Coy, Johannes F; Beets, Geerard; von Meyenfeldt, Maarten F; Leers, Math P G

    2014-05-01

    We have recently described epitope detection in macrophages (EDIM) by flow cytometry. This is a promising tool for the diagnosis and follow-up of malignancies. However, biological and technical validation is warranted before clinical applicability can be explored. The pre-analytic and analytic phases were investigated. Five different aspects were assessed: blood sample stability, intra-individual variability in healthy persons, intra-assay variation, inter-assay variation and assay transferability. The post-analytic phase was already partly standardized and described in an earlier study. The outcomes in the pre-analytic phase showed that samples are stable for 24h after venipuncture. Biological variation over time was similar to that of serum tumor marker assays; each patient has a baseline value. Intra-assay variation showed good reproducibility, while inter-assay variation showed reproducibility similar to that of to established serum tumor marker assays. Furthermore, the assay showed excellent transferability between analyzers. Under optimal analytic conditions the EDIM method is technically stable, reproducible and transferable. Biological variation over time needs further assessment in future work. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. COMPARING A NEW ALGORITHM WITH THE CLASSIC METHODS FOR ESTIMATING THE NUMBER OF FACTORS. (R826238)

    EPA Science Inventory

    This paper presents and compares a new algorithm for finding the number of factors in a data analytic model. After we describe the new method, called NUMFACT, we compare it with standard methods for finding the number of factors to use in a model. The standard methods that we ...

  12. Approximate analytical description of the elastic strain field due to an inclusion in a continuous medium with cubic anisotropy

    NASA Astrophysics Data System (ADS)

    Nenashev, A. V.; Koshkarev, A. A.; Dvurechenskii, A. V.

    2018-03-01

    We suggest an approach to the analytical calculation of the strain distribution due to an inclusion in elastically anisotropic media for the case of cubic anisotropy. The idea consists in the approximate reduction of the anisotropic problem to a (simpler) isotropic problem. This gives, for typical semiconductors, an improvement in accuracy by an order of magnitude, compared to the isotropic approximation. Our method allows using, in the case of elastically anisotropic media, analytical solutions obtained for isotropic media only, such as analytical formulas for the strain due to polyhedral inclusions. The present work substantially extends the applicability of analytical results, making them more suitable for describing real systems, such as epitaxial quantum dots.

  13. Targeted methods for quantitative analysis of protein glycosylation

    PubMed Central

    Goldman, Radoslav; Sanda, Miloslav

    2018-01-01

    Quantification of proteins by LC-MS/MS-MRM has become a standard method with broad projected clinical applicability. MRM quantification of protein modifications is, however, far less utilized, especially in the case of glycoproteins. This review summarizes current methods for quantitative analysis of protein glycosylation with a focus on MRM methods. We describe advantages of this quantitative approach, analytical parameters that need to be optimized to achieve reliable measurements, and point out the limitations. Differences between major classes of N- and O-glycopeptides are described and class-specific glycopeptide assays are demonstrated. PMID:25522218

  14. Evaluation of selected methods for determining streamflow during periods of ice effect

    USGS Publications Warehouse

    Melcher, Norwood B.; Walker, J.F.

    1992-01-01

    Seventeen methods for estimating ice-affected streamflow are evaluated for potential use with the U.S. Geological Survey streamflow-gaging station network. The methods evaluated were identified by written responses from U.S. Geological Survey field offices and by a comprehensive literature search. The methods selected and techniques used for applying the methods are described in this report. The methods are evaluated by comparing estimated results with data collected at three streamflow-gaging stations in Iowa during the winter of 1987-88. Discharge measurements were obtained at 1- to 5-day intervals during the ice-affected periods at the three stations to define an accurate baseline record. Discharge records were compiled for each method based on data available, assuming a 6-week field schedule. The methods are classified into two general categories-subjective and analytical--depending on whether individual judgment is necessary for method application. On the basis of results of the evaluation for the three Iowa stations, two of the subjective methods (discharge ratio and hydrographic-and-climatic comparison) were more accurate than the other subjective methods and approximately as accurate as the best analytical method. Three of the analytical methods (index velocity, adjusted rating curve, and uniform flow) could potentially be used at streamflow-gaging stations, where the need for accurate ice-affected discharge estimates justifies the expense of collecting additional field data. One analytical method (ice-adjustment factor) may be appropriate for use at stations with extremely stable stage-discharge ratings and measuring sections. Further research is needed to refine the analytical methods. The discharge-ratio and multiple-regression methods produce estimates of streamflow for varying ice conditions using information obtained from the existing U.S. Geological Survey streamflow-gaging network.

  15. Monte-Carlo simulation of OCT structural images of human skin using experimental B-scans and voxel based approach to optical properties distribution

    NASA Astrophysics Data System (ADS)

    Frolov, S. V.; Potlov, A. Yu.; Petrov, D. A.; Proskurin, S. G.

    2017-03-01

    A method of optical coherence tomography (OCT) structural images reconstruction using Monte Carlo simulations is described. Biological object is considered as a set of 3D elements that allow simulation of media, structure of which cannot be described analytically. Each voxel is characterized by its refractive index and anisotropy parameter, scattering and absorption coefficients. B-scans of the inner structure are used to reconstruct a simulated image instead of analytical representation of the boundary geometry. Henye-Greenstein scattering function, Beer-Lambert-Bouguer law and Fresnel equations are used for photon transport description. Efficiency of the described technique is checked by the comparison of the simulated and experimentally acquired A-scans.

  16. Data visualisation in surveillance for injury prevention and control: conceptual bases and case studies

    PubMed Central

    Martinez, Ramon; Ordunez, Pedro; Soliz, Patricia N; Ballesteros, Michael F

    2016-01-01

    Background The complexity of current injury-related health issues demands the usage of diverse and massive data sets for comprehensive analyses, and application of novel methods to communicate data effectively to the public health community, decision-makers and the public. Recent advances in information visualisation, availability of new visual analytic methods and tools, and progress on information technology provide an opportunity for shaping the next generation of injury surveillance. Objective To introduce data visualisation conceptual bases, and propose a visual analytic and visualisation platform in public health surveillance for injury prevention and control. Methods The paper introduces data visualisation conceptual bases, describes a visual analytic and visualisation platform, and presents two real-world case studies illustrating their application in public health surveillance for injury prevention and control. Results Application of visual analytic and visualisation platform is presented as solution for improved access to heterogeneous data sources, enhance data exploration and analysis, communicate data effectively, and support decision-making. Conclusions Applications of data visualisation concepts and visual analytic platform could play a key role to shape the next generation of injury surveillance. Visual analytic and visualisation platform could improve data use, the analytic capacity, and ability to effectively communicate findings and key messages. The public health surveillance community is encouraged to identify opportunities to develop and expand its use in injury prevention and control. PMID:26728006

  17. Validation protocol of analytical procedures for quantification of drugs in polymeric systems for parenteral administration: dexamethasone phosphate disodium microparticles.

    PubMed

    Martín-Sabroso, Cristina; Tavares-Fernandes, Daniel Filipe; Espada-García, Juan Ignacio; Torres-Suárez, Ana Isabel

    2013-12-15

    In this work a protocol to validate analytical procedures for the quantification of drug substances formulated in polymeric systems that comprise both drug entrapped into the polymeric matrix (assay:content test) and drug released from the systems (assay:dissolution test) is developed. This protocol is applied to the validation two isocratic HPLC analytical procedures for the analysis of dexamethasone phosphate disodium microparticles for parenteral administration. Preparation of authentic samples and artificially "spiked" and "unspiked" samples is described. Specificity (ability to quantify dexamethasone phosphate disodium in presence of constituents of the dissolution medium and other microparticle constituents), linearity, accuracy and precision are evaluated, in the range from 10 to 50 μg mL(-1) in the assay:content test procedure and from 0.25 to 10 μg mL(-1) in the assay:dissolution test procedure. The robustness of the analytical method to extract drug from microparticles is also assessed. The validation protocol developed allows us to conclude that both analytical methods are suitable for their intended purpose, but the lack of proportionality of the assay:dissolution analytical method should be taken into account. The validation protocol designed in this work could be applied to the validation of any analytical procedure for the quantification of drugs formulated in controlled release polymeric microparticles. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. The role of analytical chemistry in Niger Delta petroleum exploration: a review.

    PubMed

    Akinlua, Akinsehinwa

    2012-06-12

    Petroleum and organic matter from which the petroleum is derived are composed of organic compounds with some trace elements. These compounds give an insight into the origin, thermal maturity and paleoenvironmental history of petroleum, which are essential elements in petroleum exploration. The main tool to acquire the geochemical data is analytical techniques. Due to progress in the development of new analytical techniques, many hitherto petroleum exploration problems have been resolved. Analytical chemistry has played a significant role in the development of petroleum resources of Niger Delta. Various analytical techniques that have aided the success of petroleum exploration in the Niger Delta are discussed. The analytical techniques that have helped to understand the petroleum system of the basin are also described. Recent and emerging analytical methodologies including green analytical methods as applicable to petroleum exploration particularly Niger Delta petroleum province are discussed in this paper. Analytical chemistry is an invaluable tool in finding the Niger Delta oils. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Nine-analyte detection using an array-based biosensor

    NASA Technical Reports Server (NTRS)

    Taitt, Chris Rowe; Anderson, George P.; Lingerfelt, Brian M.; Feldstein, s. Mark. J.; Ligler, Frances S.

    2002-01-01

    A fluorescence-based multianalyte immunosensor has been developed for simultaneous analysis of multiple samples. While the standard 6 x 6 format of the array sensor has been used to analyze six samples for six different analytes, this same format has the potential to allow a single sample to be tested for 36 different agents. The method described herein demonstrates proof of principle that the number of analytes detectable using a single array can be increased simply by using complementary mixtures of capture and tracer antibodies. Mixtures were optimized to allow detection of closely related analytes without significant cross-reactivity. Following this facile modification of patterning and assay procedures, the following nine targets could be detected in a single 3 x 3 array: Staphylococcal enterotoxin B, ricin, cholera toxin, Bacillus anthracis Sterne, Bacillus globigii, Francisella tularensis LVS, Yersiniapestis F1 antigen, MS2 coliphage, and Salmonella typhimurium. This work maximizes the efficiency and utility of the described array technology, increasing only reagent usage and cost; production and fabrication costs are not affected.

  20. Calibrant-Free Analyte Quantitation via a Variable Velocity Flow Cell.

    PubMed

    Beck, Jason G; Skuratovsky, Aleksander; Granger, Michael C; Porter, Marc D

    2017-01-17

    In this paper, we describe a novel method for analyte quantitation that does not rely on calibrants, internal standards, or calibration curves but, rather, leverages the relationship between disparate and predictable surface-directed analyte flux to an array of sensing addresses and a measured resultant signal. To reduce this concept to practice, we fabricated two flow cells such that the mean linear fluid velocity, U, was varied systematically over an array of electrodes positioned along the flow axis. This resulted in a predictable variation of the address-directed flux of a redox analyte, ferrocenedimethanol (FDM). The resultant limiting currents measured at a series of these electrodes, and accurately described by a convective-diffusive transport model, provided a means to calculate an "unknown" concentration without the use of calibrants, internal standards, or a calibration curve. Furthermore, the experiment and concentration calculation only takes minutes to perform. Deviation in calculated FDM concentrations from true values was minimized to less than 0.5% when empirically derived values of U were employed.

  1. Field validation of the dnph method for aldehydes and ketones. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Workman, G.S.; Steger, J.L.

    1996-04-01

    A stationary source emission test method for selected aldehydes and ketones has been validated. The method employs a sampling train with impingers containing 2,4-dinitrophenylhydrazine (DNPH) to derivatize the analytes. The resulting hydrazones are recovered and analyzed by high performance liquid chromatography. Nine analytes were studied; the method was validated for formaldehyde, acetaldehyde, propionaldehyde, acetophenone and isophorone. Acrolein, menthyl ethyl ketone, menthyl isobutyl ketone, and quinone did not meet the validation criteria. The study employed the validation techniques described in EPA method 301, which uses train spiking to determine bias, and collocated sampling trains to determine precision. The studies were carriedmore » out at a plywood veneer dryer and a polyester manufacturing plant.« less

  2. Analytical performance specifications for changes in assay bias (Δbias) for data with logarithmic distributions as assessed by effects on reference change values.

    PubMed

    Petersen, Per H; Lund, Flemming; Fraser, Callum G; Sölétormos, György

    2016-11-01

    Background The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CV A ): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian. Methods The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical performance specifications for reference change value, with combination of Δbias and CV A based on log-Gaussian distributions of CV I as natural logarithms. The model was tested using plasma prolactin and glucose as examples. Results Analytical performance specifications for reference change value generated using the new model based on log-Gaussian distributions were practically identical with the traditional model based on Gaussian distributions. Conclusion The traditional and simple to apply model used to generate analytical performance specifications for reference change value, based on the use of coefficients of variation and assuming Gaussian distributions for both CV I and CV A , is generally useful.

  3. Teaching Analytical Method Development in an Undergraduate Instrumental Analysis Course

    ERIC Educational Resources Information Center

    Lanigan, Katherine C.

    2008-01-01

    Method development and assessment, central components of carrying out chemical research, require problem-solving skills. This article describes a pedagogical approach for teaching these skills through the adaptation of published experiments and application of group-meeting style discussions to the curriculum of an undergraduate instrumental…

  4. Hologram repositioning by an interferometric technique.

    PubMed

    Soares, O D

    1979-11-15

    An interferometric technique for hologram repositioning is described where the hologram is compared with the interference pattern of the reference and object waves. Analytical expressions to evaluate the accuracy of the repositioning are presented for the method. Two applications of the method in metrology for micromovement measurements are proposed.

  5. 40 CFR 408.141 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... apply to this subpart. (b) The term oil and grease shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217. (c) The term seafood shall...

  6. 40 CFR 408.11 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... apply to this subpart. (b) The term oil and grease shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217. (c) The term seafood shall...

  7. 40 CFR 408.51 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... apply to this subpart. (b) The term oil and grease shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217. (c) The term seafood shall...

  8. To Demonstrate the Specificity of an Enzymatic Method for Plasma Paracetamol Estimation.

    ERIC Educational Resources Information Center

    O'Mullane, John A.

    1987-01-01

    Describes an experiment designed to introduce biochemistry students to the specificity of an analytical method which uses an enzyme to quantitate its substrate. Includes the use of toxicity charts together with the concept of the biological half-life of a drug. (TW)

  9. Intellectual Biography in Higher Education: The Public Career of Earl J. McGrath as a Case Study.

    ERIC Educational Resources Information Center

    Reid, John Y.

    The method of writing an intellectual biography and the public career of Earl J. McGrath in the post-World War I cultural milieu are analyzed. One analytical framework is adapted from cultural anthropology and is used to describe the relationship of educational systems to other social systems and to culture as a whole. The second analytic frame,…

  10. Asymmetric flow field-flow fractionation (AF4) for the quantification of nanoparticle release from tablets during dissolution testing.

    PubMed

    Engel, A; Plöger, M; Mulac, D; Langer, K

    2014-01-30

    Nanoparticles composed of poly(DL-lactide-co-glycolide) (PLGA) represent promising colloidal drug carriers for improved drug targeting. Although most research activities are focused on intravenous application of these carriers the peroral administration is described to improve bioavailability of poorly soluble drugs. Based on these insights the manuscript describes a model tablet formulation for PLGA-nanoparticles and especially its analytical characterisation with regard to a nanosized drug carrier. Besides physico-chemical tablet characterisation according to pharmacopoeias the main goal of the study was the development of a suitable analytical method for the quantification of nanoparticle release from tablets. An analytical flow field-flow fractionation (AF4) method was established and validated which enables determination of nanoparticle content in solid dosage forms as well as quantification of particle release during dissolution testing. For particle detection a multi-angle light scattering (MALS) detector was coupled to the AF4-system. After dissolution testing, the presence of unaltered PLGA-nanoparticles was successfully proved by dynamic light scattering and scanning electron microscopy. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. HPLC and chemometrics-assisted UV-spectroscopy methods for the simultaneous determination of ambroxol and doxycycline in capsule

    NASA Astrophysics Data System (ADS)

    Hadad, Ghada M.; El-Gindy, Alaa; Mahmoud, Waleed M. M.

    2008-08-01

    High-performance liquid chromatography (HPLC) and multivariate spectrophotometric methods are described for the simultaneous determination of ambroxol hydrochloride (AM) and doxycycline (DX) in combined pharmaceutical capsules. The chromatographic separation was achieved on reversed-phase C 18 analytical column with a mobile phase consisting of a mixture of 20 mM potassium dihydrogen phosphate, pH 6-acetonitrile in ratio of (1:1, v/v) and UV detection at 245 nm. Also, the resolution has been accomplished by using numerical spectrophotometric methods as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS-1) applied to the UV spectra of the mixture and graphical spectrophotometric method as first derivative of the ratio spectra ( 1DD) method. Analytical figures of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of quantitation and limit of detection were determined for CLS, PLS-1 and PCR methods. The proposed methods were validated and successfully applied for the analysis of pharmaceutical formulation and laboratory-prepared mixtures containing the two component combination.

  12. HPLC and chemometrics-assisted UV-spectroscopy methods for the simultaneous determination of ambroxol and doxycycline in capsule.

    PubMed

    Hadad, Ghada M; El-Gindy, Alaa; Mahmoud, Waleed M M

    2008-08-01

    High-performance liquid chromatography (HPLC) and multivariate spectrophotometric methods are described for the simultaneous determination of ambroxol hydrochloride (AM) and doxycycline (DX) in combined pharmaceutical capsules. The chromatographic separation was achieved on reversed-phase C(18) analytical column with a mobile phase consisting of a mixture of 20mM potassium dihydrogen phosphate, pH 6-acetonitrile in ratio of (1:1, v/v) and UV detection at 245 nm. Also, the resolution has been accomplished by using numerical spectrophotometric methods as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS-1) applied to the UV spectra of the mixture and graphical spectrophotometric method as first derivative of the ratio spectra ((1)DD) method. Analytical figures of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of quantitation and limit of detection were determined for CLS, PLS-1 and PCR methods. The proposed methods were validated and successfully applied for the analysis of pharmaceutical formulation and laboratory-prepared mixtures containing the two component combination.

  13. Means of introducing an analyte into liquid sampling atmospheric pressure glow discharge

    DOEpatents

    Marcus, R. Kenneth; Quarles, Jr., Charles Derrick; Russo, Richard E.; Koppenaal, David W.; Barinaga, Charles J.; Carado, Anthony J.

    2017-01-03

    A liquid sampling, atmospheric pressure, glow discharge (LS-APGD) device as well as systems that incorporate the device and methods for using the device and systems are described. The LS-APGD includes a hollow capillary for delivering an electrolyte solution to a glow discharge space. The device also includes a counter electrode in the form of a second hollow capillary that can deliver the analyte into the glow discharge space. A voltage across the electrolyte solution and the counter electrode creates the microplasma within the glow discharge space that interacts with the analyte to move it to a higher energy state (vaporization, excitation, and/or ionization of the analyte).

  14. 40 CFR 455.50 - Identification of test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... methods cited and described in Table IG at 40 CFR 136.3(a). Pesticide manufacturers may not use the analytical method cited in Table IB, Table IC, or Table ID of 40 CFR 136.3(a) to make these determinations (except where the method cited in those tables is identical to the method specified in Table IG at 40 CFR...

  15. Synthesized airfoil data method for prediction of dynamic stall and unsteady airloads

    NASA Technical Reports Server (NTRS)

    Gangwani, S. T.

    1983-01-01

    A detailed analysis of dynamic stall experiments has led to a set of relatively compact analytical expressions, called synthesized unsteady airfoil data, which accurately describe in the time-domain the unsteady aerodynamic characteristics of stalled airfoils. An analytical research program was conducted to expand and improve this synthesized unsteady airfoil data method using additional available sets of unsteady airfoil data. The primary objectives were to reduce these data to synthesized form for use in rotor airload prediction analyses and to generalize the results. Unsteady drag data were synthesized which provided the basis for successful expansion of the formulation to include computation of the unsteady pressure drag of airfoils and rotor blades. Also, an improved prediction model for airfoil flow reattachment was incorporated in the method. Application of this improved unsteady aerodynamics model has resulted in an improved correlation between analytic predictions and measured full scale helicopter blade loads and stress data.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Ehwang; Gao, Yuqian; Wu, Chaochao

    Here, mass spectrometry (MS) based targeted proteomic methods such as selected reaction monitoring (SRM) are becoming the method of choice for preclinical verification of candidate protein biomarkers. The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute has investigated the standardization and analytical validation of the SRM assays and demonstrated robust analytical performance on different instruments across different laboratories. An Assay Portal has also been established by CPTAC to provide the research community a resource consisting of large set of targeted MS-based assays, and a depository to share assays publicly, providing that assays meet the guidelines proposed bymore » CPTAC. Herein, we report 98 SRM assays covering 70 candidate protein biomarkers previously reported as associated with ovarian cancer that have been thoroughly characterized according to the CPTAC Assay Characterization Guidance Document. The experiments, methods and results for characterizing these SRM assays for their MS response, repeatability, selectivity, stability, and reproducible detection of endogenous analytes are described in detail.« less

  17. Role of chromatography in the development of Standard Reference Materials for organic analysis.

    PubMed

    Wise, Stephen A; Phinney, Karen W; Sander, Lane C; Schantz, Michele M

    2012-10-26

    The certification of chemical constituents in natural-matrix Standard Reference Materials (SRMs) at the National Institute of Standards and Technology (NIST) can require the use of two or more independent analytical methods. The independence among the methods is generally achieved by taking advantage of differences in extraction, separation, and detection selectivity. This review describes the development of the independent analytical methods approach at NIST, and its implementation in the measurement of organic constituents such as contaminants in environmental materials, nutrients and marker compounds in food and dietary supplement matrices, and health diagnostic and nutritional assessment markers in human serum. The focus of this review is the important and critical role that separation science techniques play in achieving the necessary independence of the analytical steps in the measurement of trace-level organic constituents in natural matrix SRMs. Published by Elsevier B.V.

  18. Research education: findings of a study of teaching-learning research using multiple analytical perspectives.

    PubMed

    Vandermause, Roxanne; Barbosa-Leiker, Celestina; Fritz, Roschelle

    2014-12-01

    This multimethod, qualitative study provides results for educators of nursing doctoral students to consider. Combining the expertise of an empirical analytical researcher (who uses statistical methods) and an interpretive phenomenological researcher (who uses hermeneutic methods), a course was designed that would place doctoral students in the midst of multiparadigmatic discussions while learning fundamental research methods. Field notes and iterative analytical discussions led to patterns and themes that highlight the value of this innovative pedagogical application. Using content analysis and interpretive phenomenological approaches, together with one of the students, data were analyzed from field notes recorded in real time over the period the course was offered. This article describes the course and the study analysis, and offers the pedagogical experience as transformative. A link to a sample syllabus is included in the article. The results encourage nurse educators of doctoral nursing students to focus educational practice on multiple methodological perspectives. Copyright 2014, SLACK Incorporated.

  19. Blade loss transient dynamics analysis, volume 2. Task 2: Theoretical and analytical development. Task 3: Experimental verification

    NASA Technical Reports Server (NTRS)

    Gallardo, V. C.; Storace, A. S.; Gaffney, E. F.; Bach, L. J.; Stallone, M. J.

    1981-01-01

    The component element method was used to develop a transient dynamic analysis computer program which is essentially based on modal synthesis combined with a central, finite difference, numerical integration scheme. The methodology leads to a modular or building-block technique that is amenable to computer programming. To verify the analytical method, turbine engine transient response analysis (TETRA), was applied to two blade-out test vehicles that had been previously instrumented and tested. Comparison of the time dependent test data with those predicted by TETRA led to recommendations for refinement or extension of the analytical method to improve its accuracy and overcome its shortcomings. The development of working equations, their discretization, numerical solution scheme, the modular concept of engine modelling, the program logical structure and some illustrated results are discussed. The blade-loss test vehicles (rig full engine), the type of measured data, and the engine structural model are described.

  20. Integration within the Felsenstein equation for improved Markov chain Monte Carlo methods in population genetics

    PubMed Central

    Hey, Jody; Nielsen, Rasmus

    2007-01-01

    In 1988, Felsenstein described a framework for assessing the likelihood of a genetic data set in which all of the possible genealogical histories of the data are considered, each in proportion to their probability. Although not analytically solvable, several approaches, including Markov chain Monte Carlo methods, have been developed to find approximate solutions. Here, we describe an approach in which Markov chain Monte Carlo simulations are used to integrate over the space of genealogies, whereas other parameters are integrated out analytically. The result is an approximation to the full joint posterior density of the model parameters. For many purposes, this function can be treated as a likelihood, thereby permitting likelihood-based analyses, including likelihood ratio tests of nested models. Several examples, including an application to the divergence of chimpanzee subspecies, are provided. PMID:17301231

  1. Advances in Adaptive Control Methods

    NASA Technical Reports Server (NTRS)

    Nguyen, Nhan

    2009-01-01

    This poster presentation describes recent advances in adaptive control technology developed by NASA. Optimal Control Modification is a novel adaptive law that can improve performance and robustness of adaptive control systems. A new technique has been developed to provide an analytical method for computing time delay stability margin for adaptive control systems.

  2. ANALYSIS OF LOW-LEVEL PESTICIDES FROM HIGH-ELEVATION LAKE WATERS BY LARGE VOLUME INJECTION GCMS

    EPA Science Inventory

    This paper describes the method development for the determination of ultra-low level pesticides from high-elevation lake waters by large-volume injection programmable temperature vaporizer (LVI-PTV) GC/MS. This analytical method is developed as a subtask of a larger study, backgr...

  3. 40 CFR 408.41 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shall apply to this subpart. (b) The term oil and grease shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217. (c) The term seafood shall...

  4. Analysis of thyroid hormones in biological samples using stable isotope dilution liquid chromatography-tandem mass spectrometry

    EPA Science Inventory

    This poster presentation will describe analytical chemistry methods for measuring thyroid hormones and related precursors and metabolites in very small tissue or plasma samples. These methods are amenable to measure thyroid hormones in amphibian tadpoles or small mammals used as ...

  5. PRELIMINARY ANALYSIS OF ALTERNATIVES FOR THE LONG TERM MANAGEMENT OF EXCESS MERCURY

    EPA Science Inventory

    This report describes the use of a systematic method for comparing options for the long term management and retirement of surplus mercury in the U.S. The method chosen is the Analytical Hierarchy Procedure (AHP) as embodied in the Expert Choice 2000 software. The goal, criteria, ...

  6. Method Development for the Determination of Fluorotelomer Alcohols in Soils by Gas Chromatography Mass Spectrometry

    EPA Science Inventory

    Fluorotelomer alcohols (FTOHs) have been widely studied as precursors to perfluorocarboxylates, e.g. 8:2 FTOH degrades to perfluorooctanoic acid (PFOA). This presentation describes an analytical method for the extraction and analysis of 6:2, 8:2, and 10:2 FTOHs. Gas chromatograph...

  7. Instructional Chains as a Method for Examining the Teaching and Learning of Argumentative Writing in Classrooms

    ERIC Educational Resources Information Center

    VanDerHeide, Jennifer; Newell, George E.

    2013-01-01

    We propose "instructional chaining" as an analytic method for capturing and describing key instructional episodes enacted by expert writing teachers to foster the recontextualization over time of the social practices of argumentative writing through process-oriented instructional approaches. The article locates instructional chaining…

  8. ADVANCED EMISSIONS SPECIATION METHODOLOGIES FOR THE AUTO/OIL AIR QUALITY IMPROVEMENT RESEARCH PROGRAM - II. ALDEHYDES, KETONES, AND ALCOHOLS

    EPA Science Inventory

    Analytical methods for determining individual aldehyde, ketone, and alcohol emissions from gasoline-, methanol-, and variable-fueled vehicles are described. These methods were used in the Auto/Oil Air quality Improvement Research Program to provide emission data for comparison of...

  9. Quantifying construction and demolition waste: an analytical review.

    PubMed

    Wu, Zezhou; Yu, Ann T W; Shen, Liyin; Liu, Guiwen

    2014-09-01

    Quantifying construction and demolition (C&D) waste generation is regarded as a prerequisite for the implementation of successful waste management. In literature, various methods have been employed to quantify the C&D waste generation at both regional and project levels. However, an integrated review that systemically describes and analyses all the existing methods has yet to be conducted. To bridge this research gap, an analytical review is conducted. Fifty-seven papers are retrieved based on a set of rigorous procedures. The characteristics of the selected papers are classified according to the following criteria - waste generation activity, estimation level and quantification methodology. Six categories of existing C&D waste quantification methodologies are identified, including site visit method, waste generation rate method, lifetime analysis method, classification system accumulation method, variables modelling method and other particular methods. A critical comparison of the identified methods is given according to their characteristics and implementation constraints. Moreover, a decision tree is proposed for aiding the selection of the most appropriate quantification method in different scenarios. Based on the analytical review, limitations of previous studies and recommendations of potential future research directions are further suggested. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. An analytical approach to obtaining JWL parameters from cylinder tests

    NASA Astrophysics Data System (ADS)

    Sutton, B. D.; Ferguson, J. W.; Hodgson, A. N.

    2017-01-01

    An analytical method for determining parameters for the JWL Equation of State from cylinder test data is described. This method is applied to four datasets obtained from two 20.3 mm diameter EDC37 cylinder tests. The calculated pressure-relative volume (p-Vr) curves agree with those produced by hydro-code modelling. The average calculated Chapman-Jouguet (CJ) pressure is 38.6 GPa, compared to the model value of 38.3 GPa; the CJ relative volume is 0.729 for both. The analytical pressure-relative volume curves produced agree with the one used in the model out to the commonly reported expansion of 7 relative volumes, as do the predicted energies generated by integrating under the p-Vr curve. The calculated energy is within 1.6% of that predicted by the model.

  11. Development of an integrated BEM for hot fluid-structure interaction

    NASA Technical Reports Server (NTRS)

    Banerjee, P. K.; Dargush, G. F.

    1989-01-01

    The Boundary Element Method (BEM) is chosen as a basic analysis tool principally because the definition of quantities like fluxes, temperature, displacements, and velocities is very precise on a boundary base discretization scheme. One fundamental difficulty is, of course, that the entire analysis requires a very considerable amount of analytical work which is not present in other numerical methods. During the last 18 months all of this analytical work was completed and a two-dimensional, general purpose code was written. Some of the early results are described. It is anticipated that within the next two to three months almost all two-dimensional idealizations will be examined. It should be noted that the analytical work for the three-dimensional case has also been done and numerical implementation will begin next year.

  12. The potential contributions of geographic information science to the study of social determinants of health in Iran.

    PubMed

    Rabiei-Dastjerdi, Hamidreza; Matthews, Stephen A

    2018-01-01

    Recent interest in the social determinants of health (SDOH) and the effects of neighborhood contexts on individual health and well-being has grown exponentially. In this brief communication, we describe recent developments in both analytical perspectives and methods that have opened up new opportunities for researchers interested in exploring neighborhoods and health research within a SDOH framework. We focus specifically on recent advances in geographic information science, statistical methods, and spatial analytical tools. We close with a discussion of how these recent developments have the potential to enhance SDOH research in Iran.

  13. A generalized theory for the design of contraction cones and other low speed ducts

    NASA Technical Reports Server (NTRS)

    Barger, R. L.; Bowen, J. T.

    1972-01-01

    A generalization of the Tsien method of contraction cone design is described. The design velocity distribution is expressed in such a form that the required high order derivatives can be obtained by recursion rather than by numerical or analytic differentiation. The method is applicable to the design of diffusers and converging-diverging ducts as well as contraction cones. The computer program is described and a FORTRAN listing of the program is provided.

  14. Methods for describing the electromagnetic properties of silver and gold nanoparticles.

    PubMed

    Zhao, Jing; Pinchuk, Anatoliy O; McMahon, Jeffrey M; Li, Shuzhou; Ausman, Logan K; Atkinson, Ariel L; Schatz, George C

    2008-12-01

    This Account provides an overview of the methods that are currently being used to study the electromagnetics of silver and gold nanoparticles, with an emphasis on the determination of extinction and surface-enhanced Raman scattering (SERS) spectra. These methods have proven to be immensely useful in recent years for interpreting a wide range of nanoscience experiments and providing the capability to describe optical properties of particles up to several hundred nanometers in dimension, including arbitrary particle structures and complex dielectric environments (adsorbed layers of molecules, nearby metal films, and other particles). While some of the methods date back to Mie's celebrated work a century ago, others are still at the forefront of algorithm development in computational electromagnetics. This Account gives a qualitative description of the physical and mathematical basis behind the most commonly used methods, including both analytical and numerical methods, as well as representative results of applications that are relevant to current experiments. The analytical methods that we discuss are either derived from Mie theory for spheres or from the quasistatic (Gans) model as applied to spheres and spheroids. In this discussion, we describe the use of Mie theory to determine electromagnetic contributions to SERS enhancements that include for retarded dipole emission effects, and the use of the quasistatic approximation for spheroidal particles interacting with dye adsorbate layers. The numerical methods include the discrete dipole approximation (DDA), the finite difference time domain (FDTD) method, and the finite element method (FEM) based on Whitney forms. We discuss applications such as using DDA to describe the interaction of two gold disks to define electromagnetic hot spots, FDTD for light interacting with metal wires that go from particle-like plasmonic response to the film-like transmission as wire dimension is varied, and FEM studies of electromagnetic fields near cubic particles.

  15. VERTPAK1. Code Verification Analytic Solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golis, M.J.

    1983-04-01

    VERTPAK1 is a package of analytical solutions used in verification of numerical codes that simulate fluid flow, rock deformation, and solute transport in fractured and unfractured porous media. VERTPAK1 contains the following: BAREN, an analytical solution developed by Barenblatt, Zhelton and Kochina (1960) for describing transient flow to a well penetrating a (double porosity) confined aquifer; GIBMAC, an analytical solution developed by McNamee and Gibson (1960) for describing consolidation of a semi-infinite soil medium subject to a strip (plane strain) or cylindrical (axisymmetric) loading; GRINRH, an analytical solution developed by Gringarten (1971) for describing transient flow to a partially penetratingmore » well in a confined aquifer containing a single horizontal fracture; GRINRV, an analytical solution developed by Gringarten, Ramey, and Raghavan (1974) for describing transient flow to a fully penetrating well in a confined aquifer containing a single vertical fracture; HART, an analytical solution given by Nowacki (1962) and implemented by HART (1981) for describing the elastic behavior of an infinite solid subject to a line heat source; LESTER, an analytical solution presented by Lester, Jansen, and Burkholder (1975) for describing one-dimensional transport of radionuclide chains through an adsorbing medium; STRELT, an analytical solution presented by Streltsova-Adams (1978) for describing transient flow to a fully penetrating well in a (double porosity) confined aquifer; and TANG, an analytical solution developed by Tang, Frind, and Sudicky (1981) for describing solute transport in a porous medium containing a single fracture.« less

  16. A Requirements-Driven Optimization Method for Acoustic Liners Using Analytic Derivatives

    NASA Technical Reports Server (NTRS)

    Berton, Jeffrey J.; Lopes, Leonard V.

    2017-01-01

    More than ever, there is flexibility and freedom in acoustic liner design. Subject to practical considerations, liner design variables may be manipulated to achieve a target attenuation spectrum. But characteristics of the ideal attenuation spectrum can be difficult to know. Many multidisciplinary system effects govern how engine noise sources contribute to community noise. Given a hardwall fan noise source to be suppressed, and using an analytical certification noise model to compute a community noise measure of merit, the optimal attenuation spectrum can be derived using multidisciplinary systems analysis methods. In a previous paper on this subject, a method deriving the ideal target attenuation spectrum that minimizes noise perceived by observers on the ground was described. A simple code-wrapping approach was used to evaluate a community noise objective function for an external optimizer. Gradients were evaluated using a finite difference formula. The subject of this paper is an application of analytic derivatives that supply precise gradients to an optimization process. Analytic derivatives improve the efficiency and accuracy of gradient-based optimization methods and allow consideration of more design variables. In addition, the benefit of variable impedance liners is explored using a multi-objective optimization.

  17. Three dimensional colorimetric assay assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charych, D.; Reichart, A.

    2000-06-27

    A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flu virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.

  18. Three dimensional colorimetric assay assemblies

    DOEpatents

    Charych, Deborah; Reichart, Anke

    2000-01-01

    A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flu virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.

  19. Three-dimensional colorimetric assay assemblies

    DOEpatents

    Charych, Deborah; Reichert, Anke

    2001-01-01

    A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flue virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.

  20. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry.

    PubMed

    Ornatsky, Olga I; Kinach, Robert; Bandura, Dmitry R; Lou, Xudong; Tanner, Scott D; Baranov, Vladimir I; Nitz, Mark; Winnik, Mitchell A

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping.

  1. Viscoelastic behavior and lifetime (durability) predictions. [for laminated fiber reinforced plastics

    NASA Technical Reports Server (NTRS)

    Brinson, R. F.

    1985-01-01

    A method for lifetime or durability predictions for laminated fiber reinforced plastics is given. The procedure is similar to but not the same as the well known time-temperature-superposition principle for polymers. The method is better described as an analytical adaptation of time-stress-super-position methods. The analytical constitutive modeling is based upon a nonlinear viscoelastic constitutive model developed by Schapery. Time dependent failure models are discussed and are related to the constitutive models. Finally, results of an incremental lamination analysis using the constitutive and failure model are compared to experimental results. Favorable results between theory and predictions are presented using data from creep tests of about two months duration.

  2. The PAC-MAN model: Benchmark case for linear acoustics in computational physics

    NASA Astrophysics Data System (ADS)

    Ziegelwanger, Harald; Reiter, Paul

    2017-10-01

    Benchmark cases in the field of computational physics, on the one hand, have to contain a certain complexity to test numerical edge cases and, on the other hand, require the existence of an analytical solution, because an analytical solution allows the exact quantification of the accuracy of a numerical simulation method. This dilemma causes a need for analytical sound field formulations of complex acoustic problems. A well known example for such a benchmark case for harmonic linear acoustics is the ;Cat's Eye model;, which describes the three-dimensional sound field radiated from a sphere with a missing octant analytically. In this paper, a benchmark case for two-dimensional (2D) harmonic linear acoustic problems, viz., the ;PAC-MAN model;, is proposed. The PAC-MAN model describes the radiated and scattered sound field around an infinitely long cylinder with a cut out sector of variable angular width. While the analytical calculation of the 2D sound field allows different angular cut-out widths and arbitrarily positioned line sources, the computational cost associated with the solution of this problem is similar to a 1D problem because of a modal formulation of the sound field in the PAC-MAN model.

  3. Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: direct clinical biochemistry without reagents.

    PubMed

    Jessen, Torben E; Höskuldsson, Agnar T; Bjerrum, Poul J; Verder, Henrik; Sørensen, Lars; Bratholm, Palle S; Christensen, Bo; Jensen, Lene S; Jensen, Maria A B

    2014-09-01

    Direct measurement of chemical constituents in complex biologic matrices without the use of analyte specific reagents could be a step forward toward the simplification of clinical biochemistry. Problems related to reagents such as production errors, improper handling, and lot-to-lot variations would be eliminated as well as errors occurring during assay execution. We describe and validate a reagent free method for direct measurement of six analytes in human plasma based on Fourier-transform infrared spectroscopy (FTIR). Blood plasma is analyzed without any sample preparation. FTIR spectrum of the raw plasma is recorded in a sampling cuvette specially designed for measurement of aqueous solutions. For each analyte, a mathematical calibration process is performed by a stepwise selection of wavelengths giving the optimal least-squares correlation between the measured FTIR signal and the analyte concentration measured by conventional clinical reference methods. The developed calibration algorithms are subsequently evaluated for their capability to predict the concentration of the six analytes in blinded patient samples. The correlation between the six FTIR methods and corresponding reference methods were 0.87

  4. Fourier Transform Infrared Absorption Spectroscopy for Quantitative Analysis of Gas Mixtures at Low Temperatures for Homeland Security Applications.

    PubMed

    Meier, D C; Benkstein, K D; Hurst, W S; Chu, P M

    2017-05-01

    Performance standard specifications for point chemical vapor detectors are established in ASTM E 2885-13 and ASTM E 2933-13. The performance evaluation of the detectors requires the accurate delivery of known concentrations of the chemical target to the system under test. Referee methods enable the analyte test concentration and associated uncertainties in the analyte test concentration to be validated by independent analysis, which is especially important for reactive analytes. This work extends the capability of a previously demonstrated method for using Fourier transform infrared (FT-IR) absorption spectroscopy for quantitatively evaluating the composition of vapor streams containing hazardous materials at Acute Exposure Guideline Levels (AEGL) to include test conditions colder than laboratory ambient temperatures. The described method covers the use of primary reference spectra to establish analyte concentrations, the generation of secondary reference spectra suitable for measuring analyte concentrations under specified testing environments, and the use of additional reference spectra and spectral profile strategies to mitigate the uncertainties due to impurities and water condensation within the low-temperature (7 °C, -5 °C) test cell. Important benefits of this approach include verification of the test analyte concentration with characterized uncertainties by in situ measurements co-located with the detector under test, near-real-time feedback, and broad applicability to toxic industrial chemicals.

  5. Fourier Transform Infrared Absorption Spectroscopy for Quantitative Analysis of Gas Mixtures at Low Temperatures for Homeland Security Applications

    PubMed Central

    Meier, D.C.; Benkstein, K.D.; Hurst, W.S.; Chu, P.M.

    2016-01-01

    Performance standard specifications for point chemical vapor detectors are established in ASTM E 2885-13 and ASTM E 2933-13. The performance evaluation of the detectors requires the accurate delivery of known concentrations of the chemical target to the system under test. Referee methods enable the analyte test concentration and associated uncertainties in the analyte test concentration to be validated by independent analysis, which is especially important for reactive analytes. This work extends the capability of a previously demonstrated method for using Fourier transform infrared (FT-IR) absorption spectroscopy for quantitatively evaluating the composition of vapor streams containing hazardous materials at Acute Exposure Guideline Levels (AEGL) to include test conditions colder than laboratory ambient temperatures. The described method covers the use of primary reference spectra to establish analyte concentrations, the generation of secondary reference spectra suitable for measuring analyte concentrations under specified testing environments, and the use of additional reference spectra and spectral profile strategies to mitigate the uncertainties due to impurities and water condensation within the low-temperature (7 °C, −5 °C) test cell. Important benefits of this approach include verification of the test analyte concentration with characterized uncertainties by in situ measurements co-located with the detector under test, near-real-time feedback, and broad applicability to toxic industrial chemicals. PMID:28090126

  6. Gel-based immunotest for simultaneous detection of 2,4,6-trichlorophenol and ochratoxin A in red wine.

    PubMed

    Beloglazova, N V; Goryacheva, I Yu; Rusanova, T Yu; Yurasov, N A; Galve, R; Marco, M-P; De Saeger, S

    2010-07-05

    A new rapid method which allows simultaneous one step detection of two analytes of different nature (2,4,6,-trichlorophenol (TCP) and ochratoxin A (OTA)) in red wine was developed. It was based on a column test with three separate immunolayers: two test layers and one control layer. Each layer consisted of sepharose gel with immobilized anti-OTA (OTA test layer), anti-TCP (TCP test layer) or anti-HRP (control layer) antibodies. Analytes bind to the antibodies in the corresponding test layer while sample flows through the column. Then a mixture of OTA-HRP and TCP-HRP in appropriate dilutions was used, followed by the application of chromogenic substrate. Colour development of the test layer occurred when the corresponding analyte was absent in the sample. HRP-conjugates bound to anti-HRP antibody in the control layer independently of presence or absence of analytes and a blue colour developed in the control layer. Cut-off values for both analytes were 2 microg L(-1). The described method was applied to the simultaneous detection of TCP and OTA in wine samples. To screen the analytes in red wine samples, clean-up columns were used for sample pre-treatment in combination with the test column. Results were confirmed by chromatographic methods. Copyright 2010 Elsevier B.V. All rights reserved.

  7. Development and validation of a sensitive UHPLC-MS/MS method for the simultaneous analysis of tramadol, dextromethorphan chlorpheniramine and their major metabolites in human plasma in forensic context: application to pharmacokinetics.

    PubMed

    Heneedak, Hala M; Salama, Ismail; Mostafa, Samia; El-Kady, Ehab; El-Sadek, Mohamed

    2015-07-01

    The prerequisites for forensic confirmatory analysis by LC/MS/MS with respect to European Union guidelines are chromatographic separation, a minimum number of two MS/MS transitions to obtain the required identification points and predefined thresholds for the variability of the relative intensities of the MS/MS transitions (MRM transitions) in samples and reference standards. In the present study, a fast, sensitive and robust method to quantify tramadol, chlorpheniramine, dextromethorphan and their major metabolites, O-desmethyltramadol, dsmethyl-chlorpheniramine and dextrophan, respectively, in human plasma using ibuprofen as internal standard (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction method using ethyl acetate-diethyl-ether (1:1). Extracted samples were analyzed by ultra-high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase containing acetonitrile, water and formic acid (89.2:11.7:0.1) for 2.0 min at a flow rate of 0.25 μL/min into a Hypersil-Gold C18 column, 20 × 2.0 mm (1.9 µm) from Thermoscientific, New York, USA. The calibration curve was linear for the six analytes. The intraday precision (RSD) and accuracy (RE) of the method were 3-9.8 and -1.7-4.5%, respectively. The analytical procedure herein described was used to assess the pharmacokinetics of the analytes in 24 healthy volunteers after a single oral dose containing 50 mg of tramadol hydrochloride, 3 mg chlorpheniramine maleate and 15 mg of dextromethorphan hydrobromide. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Quantitative determination of triterpene saponins and alkenated-phenolics from Labisia pumila using LC-UV/ELSD method and confirmation by LC-ESI-TOF

    USDA-ARS?s Scientific Manuscript database

    This study describes the first analytical method for the determination of saponins and alkenated-phenolics from the leaves, leaves/stems and roots of Labisia pumila using a HPLC-UV-ELSD method. The separation was achieved using a reversed phase column, PDA and ELS detection, and a water/acetonitrile...

  9. Quantitative determination of triperpene saponins and alkenated-phenolics from Labisia pumila using LC-UV/ELSD method and confirmation by LC-ESI-TOF

    USDA-ARS?s Scientific Manuscript database

    This study describes the first analytical method for the determination of saponins and alkenated-phenolics from the leaves, leaves/stems and roots of Labisia pumila using a HPLC-UV-ELSD method. The separation was achieved using a reversed phase column, PDA and ELS detection, and a water/acetonitrile...

  10. Reader's Block: A Systematic Review of Barriers to Adoption, Access and Use in E-Book User Studies

    ERIC Educational Resources Information Center

    Girard, Adam

    2014-01-01

    Introduction: This review of barriers to e-book use systematically identifies obstacles to engaging reading experiences. Through the use of an analytical framework, the users being studied, study setting, and methods used in previous work are described in order to identify promising areas for future research. Method: The method used is a…

  11. COMPARING A NEW ALGORITHM WITH THE CLASSIC METHODS FOR ESTIMATING THE NUMBER OF FACTORS. (R825173)

    EPA Science Inventory

    Abstract

    This paper presents and compares a new algorithm for finding the number of factors in a data analytic model. After we describe the new method, called NUMFACT, we compare it with standard methods for finding the number of factors to use in a model. The standard...

  12. Analytic theory of photoacoustic wave generation from a spheroidal droplet.

    PubMed

    Li, Yong; Fang, Hui; Min, Changjun; Yuan, Xiaocong

    2014-08-25

    In this paper, we develop an analytic theory for describing the photoacoustic wave generation from a spheroidal droplet and derive the first complete analytic solution. Our derivation is based on solving the photoacoustic Helmholtz equation in spheroidal coordinates with the separation-of-variables method. As the verification, besides carrying out the asymptotic analyses which recover the standard solutions for a sphere, an infinite cylinder and an infinite layer, we also confirm that the partial transmission and reflection model previously demonstrated for these three geometries still stands. We expect that this analytic solution will find broad practical uses in interpreting experiment results, considering that its building blocks, the spheroidal wave functions (SWFs), can be numerically calculated by the existing computer programs.

  13. Analytical Chemistry Laboratory Progress Report for FY 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Boparai, A.S.; Bowers, D.L.

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year (FY) 1994 (October 1993 through September 1994). This annual report is the eleventh for the ACL and describes continuing effort on projects, work on new projects, and contributions of the ACL staff to various programs at ANL. The Analytical Chemistry Laboratory is a full-cost-recovery service center, with the primary mission of providing a broad range of analytical chemistry support services to the scientific and engineering programs at ANL. The ACL also has a research program inmore » analytical chemistry, conducts instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL handles a wide range of analytical problems. Some routine or standard analyses are done, but it is common for the Argonne programs to generate unique problems that require significant development of methods and adaption of techniques to obtain useful analytical data. The ACL has four technical groups -- Chemical Analysis, Instrumental Analysis, Organic Analysis, and Environmental Analysis -- which together include about 45 technical staff members. Talents and interests of staff members cross the group lines, as do many projects within the ACL. The Chemical Analysis Group uses wet- chemical and instrumental methods for elemental, compositional, and isotopic determinations in solid, liquid, and gaseous samples and provides specialized analytical services. Major instruments in this group include an ion chromatograph (IC), an inductively coupled plasma/atomic emission spectrometer (ICP/AES), spectrophotometers, mass spectrometers (including gas-analysis and thermal-ionization mass spectrometers), emission spectrographs, autotitrators, sulfur and carbon determinators, and a kinetic phosphorescence uranium analyzer.« less

  14. Calculating Resonance Positions and Widths Using the Siegert Approximation Method

    ERIC Educational Resources Information Center

    Rapedius, Kevin

    2011-01-01

    Here, we present complex resonance states (or Siegert states) that describe the tunnelling decay of a trapped quantum particle from an intuitive point of view that naturally leads to the easily applicable Siegert approximation method. This can be used for analytical and numerical calculations of complex resonances of both the linear and nonlinear…

  15. Using FTIR-ATR Spectroscopy to Teach the Internal Standard Method

    ERIC Educational Resources Information Center

    Bellamy, Michael K.

    2010-01-01

    The internal standard method is widely applied in quantitative analyses. However, most analytical chemistry textbooks either omit this topic or only provide examples of a single-point internal standardization. An experiment designed to teach students how to prepare an internal standard calibration curve is described. The experiment is a modified…

  16. Framework for event-based semidistributed modeling that unifies the SCS-CN method, VIC, PDM, and TOPMODEL

    NASA Astrophysics Data System (ADS)

    Bartlett, M. S.; Parolari, A. J.; McDonnell, J. J.; Porporato, A.

    2016-09-01

    Hydrologists and engineers may choose from a range of semidistributed rainfall-runoff models such as VIC, PDM, and TOPMODEL, all of which predict runoff from a distribution of watershed properties. However, these models are not easily compared to event-based data and are missing ready-to-use analytical expressions that are analogous to the SCS-CN method. The SCS-CN method is an event-based model that describes the runoff response with a rainfall-runoff curve that is a function of the cumulative storm rainfall and antecedent wetness condition. Here we develop an event-based probabilistic storage framework and distill semidistributed models into analytical, event-based expressions for describing the rainfall-runoff response. The event-based versions called VICx, PDMx, and TOPMODELx also are extended with a spatial description of the runoff concept of "prethreshold" and "threshold-excess" runoff, which occur, respectively, before and after infiltration exceeds a storage capacity threshold. For total storm rainfall and antecedent wetness conditions, the resulting ready-to-use analytical expressions define the source areas (fraction of the watershed) that produce runoff by each mechanism. They also define the probability density function (PDF) representing the spatial variability of runoff depths that are cumulative values for the storm duration, and the average unit area runoff, which describes the so-called runoff curve. These new event-based semidistributed models and the traditional SCS-CN method are unified by the same general expression for the runoff curve. Since the general runoff curve may incorporate different model distributions, it may ease the way for relating such distributions to land use, climate, topography, ecology, geology, and other characteristics.

  17. New method for investigation of cells and other biological objects in analytical cytology

    NASA Astrophysics Data System (ADS)

    Bilyi, Olexander I.; Getman, Vasyl B.; Kostyukevych, Sergey A.

    2001-05-01

    New method and instrument intended for checking the content of biology particles in dimension band 0.1-10.0 mkm in water flow is described in this report. The instrument measures the intensity of light scattered by the particles suspended in liquid flow when they are crossing the laser beam. The results of studying light scattered by platelet and bacterium's such a Pseudomonas aeruginosa, Escherichia coli, Micrococcus lutteus in such a liquid mediums as physiological solution and glucose solution are described.

  18. Green Chemistry Metrics with Special Reference to Green Analytical Chemistry.

    PubMed

    Tobiszewski, Marek; Marć, Mariusz; Gałuszka, Agnieszka; Namieśnik, Jacek

    2015-06-12

    The concept of green chemistry is widely recognized in chemical laboratories. To properly measure an environmental impact of chemical processes, dedicated assessment tools are required. This paper summarizes the current state of knowledge in the field of development of green chemistry and green analytical chemistry metrics. The diverse methods used for evaluation of the greenness of organic synthesis, such as eco-footprint, E-Factor, EATOS, and Eco-Scale are described. Both the well-established and recently developed green analytical chemistry metrics, including NEMI labeling and analytical Eco-scale, are presented. Additionally, this paper focuses on the possibility of the use of multivariate statistics in evaluation of environmental impact of analytical procedures. All the above metrics are compared and discussed in terms of their advantages and disadvantages. The current needs and future perspectives in green chemistry metrics are also discussed.

  19. Analytical aspects of hydrogen exchange mass spectrometry

    PubMed Central

    Engen, John R.; Wales, Thomas E.

    2016-01-01

    The analytical aspects of measuring hydrogen exchange by mass spectrometry are reviewed. The nature of analytical selectivity in hydrogen exchange is described followed by review of the analytical tools required to accomplish fragmentation, separation, and the mass spectrometry measurements under restrictive exchange quench conditions. In contrast to analytical quantitation that relies on measurements of peak intensity or area, quantitation in hydrogen exchange mass spectrometry depends on measuring a mass change with respect to an undeuterated or deuterated control, resulting in a value between zero and the maximum amount of deuterium that could be incorporated. Reliable quantitation is a function of experimental fidelity and to achieve high measurement reproducibility, a large number of experimental variables must be controlled during sample preparation and analysis. The method also reports on important qualitative aspects of the sample, including conformational heterogeneity and population dynamics. PMID:26048552

  20. Interpolation Hermite Polynomials For Finite Element Method

    NASA Astrophysics Data System (ADS)

    Gusev, Alexander; Vinitsky, Sergue; Chuluunbaatar, Ochbadrakh; Chuluunbaatar, Galmandakh; Gerdt, Vladimir; Derbov, Vladimir; Góźdź, Andrzej; Krassovitskiy, Pavel

    2018-02-01

    We describe a new algorithm for analytic calculation of high-order Hermite interpolation polynomials of the simplex and give their classification. A typical example of triangle element, to be built in high accuracy finite element schemes, is given.

  1. Swelling-induced and controlled curving in layered gel beams

    PubMed Central

    Lucantonio, A.; Nardinocchi, P.; Pezzulla, M.

    2014-01-01

    We describe swelling-driven curving in originally straight and non-homogeneous beams. We present and verify a structural model of swollen beams, based on a new point of view adopted to describe swelling-induced deformation processes in bilayered gel beams, that is based on the split of the swelling-induced deformation of the beam at equilibrium into two components, both depending on the elastic properties of the gel. The method allows us to: (i) determine beam stretching and curving, once assigned the characteristics of the solvent bath and of the non-homogeneous beam, and (ii) estimate the characteristics of non-homogeneous flat gel beams in such a way as to obtain, under free-swelling conditions, three-dimensional shapes. The study was pursued by means of analytical, semi-analytical and numerical tools; excellent agreement of the outcomes of the different techniques was found, thus confirming the strength of the method. PMID:25383031

  2. Net analyte signal-based simultaneous determination of ethanol and water by quartz crystal nanobalance sensor.

    PubMed

    Mirmohseni, A; Abdollahi, H; Rostamizadeh, K

    2007-02-28

    Net analyte signal (NAS)-based method called HLA/GO was applied for the selectively determination of binary mixture of ethanol and water by quartz crystal nanobalance (QCN) sensor. A full factorial design was applied for the formation of calibration and prediction sets in the concentration ranges 5.5-22.2 microg mL(-1) for ethanol and 7.01-28.07 microg mL(-1) for water. An optimal time range was selected by procedure which was based on the calculation of the net analyte signal regression plot in any considered time window for each test sample. A moving window strategy was used for searching the region with maximum linearity of NAS regression plot (minimum error indicator) and minimum of PRESS value. On the base of obtained results, the differences on the adsorption profiles in the time range between 1 and 600 s were used to determine mixtures of both compounds by HLA/GO method. The calculation of the net analytical signal using HLA/GO method allows determination of several figures of merit like selectivity, sensitivity, analytical sensitivity and limit of detection, for each component. To check the ability of the proposed method in the selection of linear regions of adsorption profile, a test for detecting non-linear regions of adsorption profile data in the presence of methanol was also described. The results showed that the method was successfully applied for the determination of ethanol and water.

  3. A new analytical method for quantification of olive and palm oil in blends with other vegetable edible oils based on the chromatographic fingerprints from the methyl-transesterified fraction.

    PubMed

    Jiménez-Carvelo, Ana M; González-Casado, Antonio; Cuadros-Rodríguez, Luis

    2017-03-01

    A new analytical method for the quantification of olive oil and palm oil in blends with other vegetable edible oils (canola, safflower, corn, peanut, seeds, grapeseed, linseed, sesame and soybean) using normal phase liquid chromatography, and applying chemometric tools was developed. The procedure for obtaining of chromatographic fingerprint from the methyl-transesterified fraction from each blend is described. The multivariate quantification methods used were Partial Least Square-Regression (PLS-R) and Support Vector Regression (SVR). The quantification results were evaluated by several parameters as the Root Mean Square Error of Validation (RMSEV), Mean Absolute Error of Validation (MAEV) and Median Absolute Error of Validation (MdAEV). It has to be highlighted that the new proposed analytical method, the chromatographic analysis takes only eight minutes and the results obtained showed the potential of this method and allowed quantification of mixtures of olive oil and palm oil with other vegetable oils. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. VERTPAK1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golis, M.J.

    1983-04-01

    VERTPAK1 is a package of analytical solutions used in verification of numerical codes that simulate fluid flow, rock deformation, and solute transport in fractured and unfractured porous media. VERTPAK1 contains the following: BAREN, an analytical solution developed by Barenblatt, Zhelton and Kochina (1960) for describing transient flow to a well penetrating a (double porosity) confined aquifer; GIBMAC, an analytical solution developed by McNamee and Gibson (1960) for describing consolidation of a semi-infinite soil medium subject to a strip (plane strain) or cylindrical (axisymmetric) loading; GRINRH, an analytical solution developed by Gringarten (1971) for describing transient flow to a partially penetratingmore » well in a confined aquifer containing a single horizontal fracture; GRINRV, an analytical solution developed by Gringarten, Ramey, and Raghavan (1974) for describing transient flow to a fully penetrating well in a confined aquifer containing a single vertical fracture; HART, an analytical solution given by Nowacki (1962) and implemented by HART (1981) for describing the elastic behavior of an infinite solid subject to a line heat source; LESTER, an analytical solution presented by Lester, Jansen, and Burkholder (1975) for describing one-dimensional transport of radionuclide chains through an adsorbing medium; STRELT, an analytical solution presented by Streltsova-Adams (1978) for describing transient flow to a fully penetrating well in a (double porosity) confined aquifer; and TANG, an analytical solution developed by Tang, Frind, and Sudicky (1981) for describing solute transport in a porous medium containing a single fracture.« less

  5. PAUSE: Predictive Analytics Using SPARQL-Endpoints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sukumar, Sreenivas R; Ainsworth, Keela; Bond, Nathaniel

    2014-07-11

    This invention relates to the medical industry and more specifically to methods of predicting risks. With the impetus towards personalized and evidence-based medicine, the need for a framework to analyze/interpret quantitative measurements (blood work, toxicology, etc.) with qualitative descriptions (specialist reports after reading images, bio-medical knowledgebase, etc.) to predict diagnostic risks is fast emerging. We describe a software solution that leverages hardware for scalable in-memory analytics and applies next-generation semantic query tools on medical data.

  6. A pipette-based calibration system for fast-scan cyclic voltammetry with fast response times.

    PubMed

    Ramsson, Eric S

    2016-01-01

    Fast-scan cyclic voltammetry (FSCV) is an electrochemical technique that utilizes the oxidation and/or reduction of an analyte of interest to infer rapid changes in concentrations. In order to calibrate the resulting oxidative or reductive current, known concentrations of an analyte must be introduced under controlled settings. Here, I describe a simple and cost-effective method, using a Petri dish and pipettes, for the calibration of carbon fiber microelectrodes (CFMs) using FSCV.

  7. Recursively constructing analytic expressions for equilibrium distributions of stochastic biochemical reaction networks.

    PubMed

    Meng, X Flora; Baetica, Ania-Ariadna; Singhal, Vipul; Murray, Richard M

    2017-05-01

    Noise is often indispensable to key cellular activities, such as gene expression, necessitating the use of stochastic models to capture its dynamics. The chemical master equation (CME) is a commonly used stochastic model of Kolmogorov forward equations that describe how the probability distribution of a chemically reacting system varies with time. Finding analytic solutions to the CME can have benefits, such as expediting simulations of multiscale biochemical reaction networks and aiding the design of distributional responses. However, analytic solutions are rarely known. A recent method of computing analytic stationary solutions relies on gluing simple state spaces together recursively at one or two states. We explore the capabilities of this method and introduce algorithms to derive analytic stationary solutions to the CME. We first formally characterize state spaces that can be constructed by performing single-state gluing of paths, cycles or both sequentially. We then study stochastic biochemical reaction networks that consist of reversible, elementary reactions with two-dimensional state spaces. We also discuss extending the method to infinite state spaces and designing the stationary behaviour of stochastic biochemical reaction networks. Finally, we illustrate the aforementioned ideas using examples that include two interconnected transcriptional components and biochemical reactions with two-dimensional state spaces. © 2017 The Author(s).

  8. Recursively constructing analytic expressions for equilibrium distributions of stochastic biochemical reaction networks

    PubMed Central

    Baetica, Ania-Ariadna; Singhal, Vipul; Murray, Richard M.

    2017-01-01

    Noise is often indispensable to key cellular activities, such as gene expression, necessitating the use of stochastic models to capture its dynamics. The chemical master equation (CME) is a commonly used stochastic model of Kolmogorov forward equations that describe how the probability distribution of a chemically reacting system varies with time. Finding analytic solutions to the CME can have benefits, such as expediting simulations of multiscale biochemical reaction networks and aiding the design of distributional responses. However, analytic solutions are rarely known. A recent method of computing analytic stationary solutions relies on gluing simple state spaces together recursively at one or two states. We explore the capabilities of this method and introduce algorithms to derive analytic stationary solutions to the CME. We first formally characterize state spaces that can be constructed by performing single-state gluing of paths, cycles or both sequentially. We then study stochastic biochemical reaction networks that consist of reversible, elementary reactions with two-dimensional state spaces. We also discuss extending the method to infinite state spaces and designing the stationary behaviour of stochastic biochemical reaction networks. Finally, we illustrate the aforementioned ideas using examples that include two interconnected transcriptional components and biochemical reactions with two-dimensional state spaces. PMID:28566513

  9. Prediction of light aircraft interior noise

    NASA Technical Reports Server (NTRS)

    Howlett, J. T.; Morales, D. A.

    1976-01-01

    At the present time, predictions of aircraft interior noise depend heavily on empirical correction factors derived from previous flight measurements. However, to design for acceptable interior noise levels and to optimize acoustic treatments, analytical techniques which do not depend on empirical data are needed. This paper describes a computerized interior noise prediction method for light aircraft. An existing analytical program (developed for commercial jets by Cockburn and Jolly in 1968) forms the basis of some modal analysis work which is described. The accuracy of this modal analysis technique for predicting low-frequency coupled acoustic-structural natural frequencies is discussed along with trends indicating the effects of varying parameters such as fuselage length and diameter, structural stiffness, and interior acoustic absorption.

  10. Recursive analytical solution describing artificial satellite motion perturbed by an arbitrary number of zonal terms

    NASA Technical Reports Server (NTRS)

    Mueller, A. C.

    1977-01-01

    An analytical first order solution has been developed which describes the motion of an artificial satellite perturbed by an arbitrary number of zonal harmonics of the geopotential. A set of recursive relations for the solution, which was deduced from recursive relations of the geopotential, was derived. The method of solution is based on Von-Zeipel's technique applied to a canonical set of two-body elements in the extended phase space which incorporates the true anomaly as a canonical element. The elements are of Poincare type, that is, they are regular for vanishing eccentricities and inclinations. Numerical results show that this solution is accurate to within a few meters after 500 revolutions.

  11. Analytical and experimental studies of natural vibrations modes of ring-stiffened truncated-cone shells with variable theoretical ring fixity

    NASA Technical Reports Server (NTRS)

    Naumann, E. C.; Catherines, D. S.; Walton, W. C., Jr.

    1971-01-01

    Experimental and analytical investigations of the vibratory behavior of ring-stiffened truncated-cone shells are described. Vibration tests were conducted on 60 deg conical shells having up to four ring stiffeners and for free-free and clamped-free edge constraints and 9 deg conical shells, for two thicknesses, each with two angle rings and for free-free, free-clamped, and clamped-clamped edge constraints. The analytical method is based on linear thin shell theory, employing the Rayleigh-Ritz method. Discrete rings are represented as composed of one or more segments, each of which is a short truncated-cone shell of uniform thickness. Equations of constraint are used to join a ring and shell along a circumferential line connection. Excellent agreement was obtained for comparisons of experimental and calculated frequencies.

  12. Survey of NASA research on crash dynamics

    NASA Technical Reports Server (NTRS)

    Thomson, R. G.; Carden, H. D.; Hayduk, R. J.

    1984-01-01

    Ten years of structural crash dynamics research activities conducted on general aviation aircraft by the National Aeronautics and Space Administration (NASA) are described. Thirty-two full-scale crash tests were performed at Langley Research Center, and pertinent data on airframe and seat behavior were obtained. Concurrent with the experimental program, analytical methods were developed to help predict structural behavior during impact. The effects of flight parameters at impact on cabin deceleration pulses at the seat/occupant interface, experimental and analytical correlation of data on load-limiting subfloor and seat configurations, airplane section test results for computer modeling validation, and data from emergency-locator-transmitter (ELT) investigations to determine probable cause of false alarms and nonactivations are assessed. Computer programs which provide designers with analytical methods for predicting accelerations, velocities, and displacements of collapsing structures are also discussed.

  13. Study and characterization of a MEMS micromirror device

    NASA Astrophysics Data System (ADS)

    Furlong, Cosme; Pryputniewicz, Ryszard J.

    2004-08-01

    In this paper, advances in our study and characterization of a MEMS micromirror device are presented. The micromirror device, of 510 mm characteristic length, operates in a dynamic mode with a maximum displacement on the order of 10 mm along its principal optical axis and oscillation frequencies of up to 1.3 kHz. Developments are carried on by analytical, computational, and experimental methods. Analytical and computational nonlinear geometrical models are developed in order to determine the optimal loading-displacement operational characteristics of the micromirror. Due to the operational mode of the micromirror, the experimental characterization of its loading-displacement transfer function requires utilization of advanced optical metrology methods. Optoelectronic holography (OEH) methodologies based on multiple wavelengths that we are developing to perform such characterization are described. It is shown that the analytical, computational, and experimental approach is effective in our developments.

  14. Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Judkoff, Ronald; Neymark, Joel; Kennedy, Mike D.

    This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area ofmore » modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.« less

  15. An Analytical Approach to Obtaining JWL Parameters from Cylinder Tests

    NASA Astrophysics Data System (ADS)

    Sutton, Ben; Ferguson, James

    2015-06-01

    An analytical method for determining parameters for the JWL equation of state (EoS) from cylinder test data is described. This method is applied to four datasets obtained from two 20.3 mm diameter EDC37 cylinder tests. The calculated parameters and pressure-volume (p-V) curves agree with those produced by hydro-code modelling. The calculated Chapman-Jouguet (CJ) pressure is 38.6 GPa, compared to the model value of 38.3 GPa; the CJ relative volume is 0.729 for both. The analytical pressure-volume curves produced agree with the one used in the model out to the commonly reported expansion of 7 relative volumes, as do the predicted energies generated by integrating under the p-V curve. The calculated and model energies are 8.64 GPa and 8.76 GPa respectively.

  16. Analysis of Ethanolamines: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS888

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Vu, A; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled 'Analysis of Diethanolamine, Triethanolamine, n-Methyldiethanolamine, and n-Ethyldiethanolamine in Water by Single Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): EPA Method MS888'. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in 'EPA Method MS888' for analysis of themore » listed ethanolamines in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of 'EPA Method MS888' can be determined.« less

  17. Evaluation of analytical performance based on partial order methodology.

    PubMed

    Carlsen, Lars; Bruggemann, Rainer; Kenessova, Olga; Erzhigitov, Erkin

    2015-01-01

    Classical measurements of performances are typically based on linear scales. However, in analytical chemistry a simple scale may be not sufficient to analyze the analytical performance appropriately. Here partial order methodology can be helpful. Within the context described here, partial order analysis can be seen as an ordinal analysis of data matrices, especially to simplify the relative comparisons of objects due to their data profile (the ordered set of values an object have). Hence, partial order methodology offers a unique possibility to evaluate analytical performance. In the present data as, e.g., provided by the laboratories through interlaboratory comparisons or proficiency testings is used as an illustrative example. However, the presented scheme is likewise applicable for comparison of analytical methods or simply as a tool for optimization of an analytical method. The methodology can be applied without presumptions or pretreatment of the analytical data provided in order to evaluate the analytical performance taking into account all indicators simultaneously and thus elucidating a "distance" from the true value. In the present illustrative example it is assumed that the laboratories analyze a given sample several times and subsequently report the mean value, the standard deviation and the skewness, which simultaneously are used for the evaluation of the analytical performance. The analyses lead to information concerning (1) a partial ordering of the laboratories, subsequently, (2) a "distance" to the Reference laboratory and (3) a classification due to the concept of "peculiar points". Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Concept Development for Future Domains: A New Method of Knowledge Elicitation

    DTIC Science & Technology

    2005-06-01

    Procedure: U.S. Army Research Institute for the Behavioral and Social Sciences (ARI) examined methods to generate, refine, test , and validate new...generate, elaborate, refine, describe, test , and validate new Future Force concepts relating to doctrine, tactics, techniques, procedures, unit and team...System (Harvey, 1993), and the Job Element Method (Primoff & Eyde , 1988). Figure 1 provides a more comprehensive list of task analytic methods. Please see

  19. PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao

    2014-10-27

    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as highmore » resolution separations.« less

  20. Analytical validation of a novel multiplex test for detection of advanced adenoma and colorectal cancer in symptomatic patients.

    PubMed

    Dillon, Roslyn; Croner, Lisa J; Bucci, John; Kairs, Stefanie N; You, Jia; Beasley, Sharon; Blimline, Mark; Carino, Rochele B; Chan, Vicky C; Cuevas, Danissa; Diggs, Jeff; Jennings, Megan; Levy, Jacob; Mina, Ginger; Yee, Alvin; Wilcox, Bruce

    2018-05-30

    Early detection of colorectal cancer (CRC) is key to reducing associated mortality. Despite the importance of early detection, approximately 40% of individuals in the United States between the ages of 50-75 have never been screened for CRC. The low compliance with colonoscopy and fecal-based screening may be addressed with a non-invasive alternative such as a blood-based test. We describe here the analytical validation of a multiplexed blood-based assay that measures the plasma concentrations of 15 proteins to assess advanced adenoma (AA) and CRC risk in symptomatic patients. The test was developed on an electrochemiluminescent immunoassay platform employing four multi-marker panels, to be implemented in the clinic as a laboratory developed test (LDT). Under the Clinical Laboratory Improvement Amendments (CLIA) and College of American Pathologists (CAP) regulations, a United States-based clinical laboratory utilizing an LDT must establish performance characteristics relating to analytical validity prior to releasing patient test results. This report describes a series of studies demonstrating the precision, accuracy, analytical sensitivity, and analytical specificity for each of the 15 assays, as required by CLIA/CAP. In addition, the report describes studies characterizing each of the assays' dynamic range, parallelism, tolerance to common interfering substances, spike recovery, and stability to sample freeze-thaw cycles. Upon completion of the analytical characterization, a clinical accuracy study was performed to evaluate concordance of AA and CRC classifier model calls using the analytical method intended for use in the clinic. Of 434 symptomatic patient samples tested, the percent agreement with original CRC and AA calls was 87% and 92% respectively. All studies followed CLSI guidelines and met the regulatory requirements for implementation of a new LDT. The results provide the analytical evidence to support the implementation of the novel multi-marker test as a clinical test for evaluating CRC and AA risk in symptomatic individuals. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Analytical Characterization on Pulse Propagation in a Semiconductor Optical Amplifier Based on Homotopy Analysis Method

    NASA Astrophysics Data System (ADS)

    Jia, Xiaofei

    2018-06-01

    Starting from the basic equations describing the evolution of the carriers and photons inside a semiconductor optical amplifier (SOA), the equation governing pulse propagation in the SOA is derived. By employing homotopy analysis method (HAM), a series solution for the output pulse by the SOA is obtained, which can effectively characterize the temporal features of the nonlinear process during the pulse propagation inside the SOA. Moreover, the analytical solution is compared with numerical simulations with a good agreement. The theoretical results will benefit the future analysis of other problems related to the pulse propagation in the SOA.

  2. Implementation of structural response sensitivity calculations in a large-scale finite-element analysis system

    NASA Technical Reports Server (NTRS)

    Giles, G. L.; Rogers, J. L., Jr.

    1982-01-01

    The methodology used to implement structural sensitivity calculations into a major, general-purpose finite-element analysis system (SPAR) is described. This implementation includes a generalized method for specifying element cross-sectional dimensions as design variables that can be used in analytically calculating derivatives of output quantities from static stress, vibration, and buckling analyses for both membrane and bending elements. Limited sample results for static displacements and stresses are presented to indicate the advantages of analytically calculating response derivatives compared to finite difference methods. Continuing developments to implement these procedures into an enhanced version of SPAR are also discussed.

  3. Quantitative PCR for Genetic Markers of Human Fecal Pollution

    EPA Science Inventory

    Assessment of health risk and fecal bacteria loads associated with human fecal pollution requires reliable host-specific analytical methods and a rapid quantificationapproach. We report the development of quantitative PCR assays for quantification of two recently described human-...

  4. EPA-ORD MEASUREMENT SCIENCE SUPPORT FOR HOMELAND SECURITY

    EPA Science Inventory

    This presentation will describe the organization and the research and development activities of the ORD National Exposure Measurements Center and will focus on the Center's planned role in providing analytical method development, statistical sampling and design guidance, quality ...

  5. THEORETICAL METHODS FOR COMPUTING ELECTRICAL CONDITIONS IN WIRE-PLATE ELECTROSTATIC PRECIPITATORS

    EPA Science Inventory

    The paper describes a new semi-empirical, approximate theory for predicting electrical conditions. In the approximate theory, analytical expressions are derived for calculating voltage-current characteristics and electric potential, electric field, and space charge density distri...

  6. An Analytical Solution for Yaw Maneuver Optimization on the International Space Station and Other Orbiting Space Vehicles

    NASA Technical Reports Server (NTRS)

    Dobrinskaya, Tatiana

    2015-01-01

    This paper suggests a new method for optimizing yaw maneuvers on the International Space Station (ISS). Yaw rotations are the most common large maneuvers on the ISS often used for docking and undocking operations, as well as for other activities. When maneuver optimization is used, large maneuvers, which were performed on thrusters, could be performed either using control moment gyroscopes (CMG), or with significantly reduced thruster firings. Maneuver optimization helps to save expensive propellant and reduce structural loads - an important factor for the ISS service life. In addition, optimized maneuvers reduce contamination of the critical elements of the vehicle structure, such as solar arrays. This paper presents an analytical solution for optimizing yaw attitude maneuvers. Equations describing pitch and roll motion needed to counteract the major torques during a yaw maneuver are obtained. A yaw rate profile is proposed. Also the paper describes the physical basis of the suggested optimization approach. In the obtained optimized case, the torques are significantly reduced. This torque reduction was compared to the existing optimization method which utilizes the computational solution. It was shown that the attitude profiles and the torque reduction have a good match for these two methods of optimization. The simulations using the ISS flight software showed similar propellant consumption for both methods. The analytical solution proposed in this paper has major benefits with respect to computational approach. In contrast to the current computational solution, which only can be calculated on the ground, the analytical solution does not require extensive computational resources, and can be implemented in the onboard software, thus, making the maneuver execution automatic. The automatic maneuver significantly simplifies the operations and, if necessary, allows to perform a maneuver without communication with the ground. It also reduces the probability of command errors. The suggested analytical solution provides a new method of maneuver optimization which is less complicated, automatic and more universal. A maneuver optimization approach, presented in this paper, can be used not only for the ISS, but for other orbiting space vehicles.

  7. Comparison of critical methods developed for fatty acid analysis: A review.

    PubMed

    Wu, Zhuona; Zhang, Qi; Li, Ning; Pu, Yiqiong; Wang, Bing; Zhang, Tong

    2017-01-01

    Fatty acids are important nutritional substances and metabolites in living organisms. These acids are abundant in Chinese herbs, such as Brucea javanica, Notopterygium forbesii, Isatis tinctoria, Astragalus membranaceus, and Aconitum szechenyianum. This review illustrates the types of fatty acids and their significant roles in the human body. Many analytical methods are used for the qualitative and quantitative evaluation of fatty acids. Some of the methods used to analyze fatty acids in more than 30 kinds of plants, drugs, and other samples are presented in this paper. These analytical methods include gas chromatography, liquid chromatography, near-infrared spectroscopy, and NMR spectroscopy. The advantages and disadvantages of these techniques are described and compared. This review provides a valuable reference for establishing methods for fatty acid determination. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. An algebraic homotopy method for generating quasi-three-dimensional grids for high-speed configurations

    NASA Technical Reports Server (NTRS)

    Moitra, Anutosh

    1989-01-01

    A fast and versatile procedure for algebraically generating boundary conforming computational grids for use with finite-volume Euler flow solvers is presented. A semi-analytic homotopic procedure is used to generate the grids. Grids generated in two-dimensional planes are stacked to produce quasi-three-dimensional grid systems. The body surface and outer boundary are described in terms of surface parameters. An interpolation scheme is used to blend between the body surface and the outer boundary in order to determine the field points. The method, albeit developed for analytically generated body geometries is equally applicable to other classes of geometries. The method can be used for both internal and external flow configurations, the only constraint being that the body geometries be specified in two-dimensional cross-sections stationed along the longitudinal axis of the configuration. Techniques for controlling various grid parameters, e.g., clustering and orthogonality are described. Techniques for treating problems arising in algebraic grid generation for geometries with sharp corners are addressed. A set of representative grid systems generated by this method is included. Results of flow computations using these grids are presented for validation of the effectiveness of the method.

  9. Analytic Evolution of Singular Distribution Amplitudes in QCD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tandogan Kunkel, Asli

    2014-08-01

    Distribution amplitudes (DAs) are the basic functions that contain information about the quark momentum. DAs are necessary to describe hard exclusive processes in quantum chromodynamics. We describe a method of analytic evolution of DAs that have singularities such as nonzero values at the end points of the support region, jumps at some points inside the support region and cusps. We illustrate the method by applying it to the evolution of a at (constant) DA, antisymmetric at DA, and then use the method for evolution of the two-photon generalized distribution amplitude. Our approach to DA evolution has advantages over the standardmore » method of expansion in Gegenbauer polynomials [1, 2] and over a straightforward iteration of an initial distribution with evolution kernel. Expansion in Gegenbauer polynomials requires an infinite number of terms in order to accurately reproduce functions in the vicinity of singular points. Straightforward iteration of an initial distribution produces logarithmically divergent terms at each iteration. In our method the logarithmic singularities are summed from the start, which immediately produces a continuous curve. Afterwards, in order to get precise results, only one or two iterations are needed.« less

  10. Means and method of detection in chemical separation procedures

    DOEpatents

    Yeung, E.S.; Koutny, L.B.; Hogan, B.L.; Cheung, C.K.; Yinfa Ma.

    1993-03-09

    A means and method are described for indirect detection of constituent components of a mixture separated in a chemical separation process. Fluorescing ions are distributed across the area in which separation of the mixture will occur to provide a generally uniform background fluorescence intensity. For example, the mixture is comprised of one or more charged analytes which displace fluorescing ions where its constituent components separate to. Fluorescing ions of the same charge as the charged analyte components cause a displacement. The displacement results in the location of the separated components having a reduced fluorescence intensity to the remainder of the background. Detection of the lower fluorescence intensity areas can be visually, by photographic means and methods, or by automated laser scanning.

  11. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry

    PubMed Central

    Ornatsky, Olga I.; Kinach, Robert; Bandura, Dmitry R.; Lou, Xudong; Tanner, Scott D.; Baranov, Vladimir I.; Nitz, Mark; Winnik, Mitchell A.

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping. PMID:19122859

  12. Teaching Cell Biology in the Large-Enrollment Classroom: Methods to Promote Analytical Thinking and Assessment of Their Effectiveness

    PubMed Central

    Kitchen, Elizabeth; Bell, John D.; Reeve, Suzanne; Sudweeks, Richard R.; Bradshaw, William S.

    2003-01-01

    A large-enrollment, undergraduate cellular biology lecture course is described whose primary goal is to help students acquire skill in the interpretation of experimental data. The premise is that this kind of analytical reasoning is not intuitive for most people and, in the absence of hands-on laboratory experience, will not readily develop unless instructional methods and examinations specifically designed to foster it are employed. Promoting scientific thinking forces changes in the roles of both teacher and student. We describe didactic strategies that include directed practice of data analysis in a workshop format, active learning through verbal and written communication, visualization of abstractions diagrammatically, and the use of ancillary small-group mentoring sessions with faculty. The implications for a teacher in reducing the breadth and depth of coverage, becoming coach instead of lecturer, and helping students to diagnose cognitive weaknesses are discussed. In order to determine the efficacy of these strategies, we have carefully monitored student performance and have demonstrated a large gain in a pre- and posttest comparison of scores on identical problems, improved test scores on several successive midterm examinations when the statistical analysis accounts for the relative difficulty of the problems, and higher scores in comparison to students in a control course whose objective was information transfer, not acquisition of reasoning skills. A novel analytical index (student mobility profile) is described that demonstrates that this improvement was not random, but a systematic outcome of the teaching/learning strategies employed. An assessment of attitudes showed that, in spite of finding it difficult, students endorse this approach to learning, but also favor curricular changes that would introduce an analytical emphasis earlier in their training. PMID:14506506

  13. IBM’s Health Analytics and Clinical Decision Support

    PubMed Central

    Sun, J.; Knoop, S.; Shabo, A.; Carmeli, B.; Sow, D.; Syed-Mahmood, T.; Rapp, W.

    2014-01-01

    Summary Objectives This survey explores the role of big data and health analytics developed by IBM in supporting the transformation of healthcare by augmenting evidence-based decision-making. Methods Some problems in healthcare and strategies for change are described. It is argued that change requires better decisions, which, in turn, require better use of the many kinds of healthcare information. Analytic resources that address each of the information challenges are described. Examples of the role of each of the resources are given. Results There are powerful analytic tools that utilize the various kinds of big data in healthcare to help clinicians make more personalized, evidenced-based decisions. Such resources can extract relevant information and provide insights that clinicians can use to make evidence-supported decisions. There are early suggestions that these resources have clinical value. As with all analytic tools, they are limited by the amount and quality of data. Conclusion Big data is an inevitable part of the future of healthcare. There is a compelling need to manage and use big data to make better decisions to support the transformation of healthcare to the personalized, evidence-supported model of the future. Cognitive computing resources are necessary to manage the challenges in employing big data in healthcare. Such tools have been and are being developed. The analytic resources, themselves, do not drive, but support healthcare transformation. PMID:25123736

  14. A transient laboratory method for determining the hydraulic properties of 'tight' rocks-I. Theory

    USGS Publications Warehouse

    Hsieh, P.A.; Tracy, J.V.; Neuzil, C.E.; Bredehoeft, J.D.; Silliman, Stephen E.

    1981-01-01

    Transient pulse testing has been employed increasingly in the laboratory to measure the hydraulic properties of rock samples with low permeability. Several investigators have proposed a mathematical model in terms of an initial-boundary value problem to describe fluid flow in a transient pulse test. However, the solution of this problem has not been available. In analyzing data from the transient pulse test, previous investigators have either employed analytical solutions that are derived with the use of additional, restrictive assumptions, or have resorted to numerical methods. In Part I of this paper, a general, analytical solution for the transient pulse test is presented. This solution is graphically illustrated by plots of dimensionless variables for several cases of interest. The solution is shown to contain, as limiting cases, the more restrictive analytical solutions that the previous investigators have derived. A method of computing both the permeability and specific storage of the test sample from experimental data will be presented in Part II. ?? 1981.

  15. Targeted proteomic assays for quantitation of proteins identified by proteogenomic analysis of ovarian cancer

    DOE PAGES

    Song, Ehwang; Gao, Yuqian; Wu, Chaochao; ...

    2017-07-19

    Here, mass spectrometry (MS) based targeted proteomic methods such as selected reaction monitoring (SRM) are becoming the method of choice for preclinical verification of candidate protein biomarkers. The Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute has investigated the standardization and analytical validation of the SRM assays and demonstrated robust analytical performance on different instruments across different laboratories. An Assay Portal has also been established by CPTAC to provide the research community a resource consisting of large set of targeted MS-based assays, and a depository to share assays publicly, providing that assays meet the guidelines proposed bymore » CPTAC. Herein, we report 98 SRM assays covering 70 candidate protein biomarkers previously reported as associated with ovarian cancer that have been thoroughly characterized according to the CPTAC Assay Characterization Guidance Document. The experiments, methods and results for characterizing these SRM assays for their MS response, repeatability, selectivity, stability, and reproducible detection of endogenous analytes are described in detail.« less

  16. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS.

    PubMed

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I; Fokina, Valentina M; Nanovskaya, Tatiana N; Hankins, Gary D V; Ahmed, Mahmoud S

    2015-04-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87-99%, and that from urine samples was 85-95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100-0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984-1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy was 86-114% in plasma, and 94-105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Quantitative determination of metformin, glyburide and its metabolites in plasma and urine of pregnant patients by LC-MS/MS

    PubMed Central

    Zhang, Xing; Wang, Xiaoming; Vernikovskaya, Daria I.; Fokina, Valentina M.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2014-01-01

    This report describes the development and validation of an LC-MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3, and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples ranged between 87% and 99%, and 85%–95% for urine samples. The differences in retention times among the analytes, and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL and 4.95 ng/mL for MET. LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 μg/mL for MET. The relative deviation of this method was < 14% for intra-day and inter-day assays in plasma and urine samples, and the accuracy ranged between 86% and 114% in plasma, and 94% to 105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. PMID:25164921

  18. Liquid chromatographic tandem mass spectrometric assay for quantification of 97/78 and its metabolite 97/63: a promising trioxane antimalarial in monkey plasma.

    PubMed

    Singh, R P; Sabarinath, S; Gautam, N; Gupta, R C; Singh, S K

    2009-07-15

    The present manuscript describes development and validation of LC-MS/MS assay for the simultaneous quantitation of 97/78 and its active in-vivo metabolite 97/63 in monkey plasma using alpha-arteether as internal standard (IS). The method involves a single step protein precipitation using acetonitrile as extraction method. The analytes were separated on a Columbus C(18) (50 mm x 2 mm i.d., 5 microm particle size) column by isocratic elution with acetonitrile:ammonium acetate buffer (pH 4, 10 mM) (80:20 v/v) at a flow rate of 0.45 mL/min, and analyzed by mass spectrometry in multiple reaction-monitoring (MRM) positive ion mode. The chromatographic run time was 4.0 min and the weighted (1/x(2)) calibration curves were linear over a range of 1.56-200 ng/mL. The method was linear for both the analytes with correlation coefficients >0.995. The intra-day and inter-day accuracy (% bias) and precisions (% RSD) of the assay were less than 6.27%. Both analytes were stable after three freeze-thaw cycles (% deviation <8.2) and also for 30 days in plasma (% deviation <6.7). The absolute recoveries of 97/78, 97/63 and internal standard (IS), from spiked plasma samples were >90%. The validated assay method, described here, was successfully applied to the pharmacokinetic study of 97/78 and its active in-vivo metabolite 97/63 in Rhesus monkeys.

  19. Determination of Calcium in Dietary Supplements: Statistical Comparison of Methods in the Analytical Laboratory

    ERIC Educational Resources Information Center

    Garvey, Sarah L.; Shahmohammadi, Golbon; McLain, Derek R.; Dietz, Mark L.

    2015-01-01

    A laboratory experiment is described in which students compare two methods for the determination of the calcium content of commercial dietary supplement tablets. In a two-week sequence, the sample tablets are first analyzed via complexometric titration with ethylenediaminetetraacetic acid and then, following ion exchange of the calcium ion present…

  20. Assessing and Analyzing Change in Attitudes in the Classroom

    ERIC Educational Resources Information Center

    Tractenberg, Rochelle E.; Chaterji, Ranjana; Haramati, Aviad

    2007-01-01

    We explore three analytic methods that can be used to quantify and qualify changes in attitude and similar outcomes that may be encountered in the educational context. These methods can be used or adapted whenever the outcome of interest is change in a generally unmeasurable attribute, such as attitude. The analyses we describe focus on: (1)…

  1. Nondestructive assessment of timber bridges using a vibration-based method

    Treesearch

    Xiping Wang; James P. Wacker; Robert J. Ross; Brian K. Brashaw

    2005-01-01

    This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...

  2. The Art of Observation: Issues and Potential of Using Photo-Methods in Critical Ethnography with Adolescents

    ERIC Educational Resources Information Center

    Boucher, Michael L., Jr.

    2017-01-01

    The use of photographs in ethnographic education research is an emerging method that promises to enable scholars to collect deeper, more meaningful data from individuals who may otherwise be silenced. When used to empower participants, photo methodologies can remove what Foucault (1980) described as the analytical "gaze," allowing for…

  3. Measurement of Enzyme Kinetics by Use of a Blood Glucometer: Hydrolysis of Sucrose and Lactose

    ERIC Educational Resources Information Center

    Heinzerling, Peter; Schrader, Frank; Schanze, Sascha

    2012-01-01

    An alternative analytical method for measuring the kinetic parameters of the enzymes invertase and lactase is described. Invertase hydrolyzes sucrose to glucose and fructose and lactase hydrolyzes lactose to glucose and galactose. In most enzyme kinetics studies, photometric methods or test strips are used to quantify the derivates of the…

  4. Analysis of Carbamate Pesticides: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS666

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for analysis of aldicarb, bromadiolone, carbofuran, oxamyl, and methomyl in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS666. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in MS666 for analysis of carbamatemore » pesticides in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS666 can be determined.« less

  5. Analysis of Thiodiglycol: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS777

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for the analysis of thiodiglycol, the breakdown product of the sulfur mustard HD, in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS777 (hereafter referred to as EPA CRL SOP MS777). This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to verifymore » the analytical procedures described in MS777 for analysis of thiodiglycol in aqueous samples. The gathered data from this study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS777 can be determined.« less

  6. Rapid and continuous analyte processing in droplet microfluidic devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strey, Helmut; Kimmerling, Robert; Bakowski, Tomasz

    The compositions and methods described herein are designed to introduce functionalized microparticles into droplets that can be manipulated in microfluidic devices by fields, including electric (dielectrophoretic) or magnetic fields, and extracted by splitting a droplet to separate the portion of the droplet that contains the majority of the microparticles from the part that is largely devoid of the microparticles. Within the device, channels are variously configured at Y- or T junctions that facilitate continuous, serial isolation and dilution of analytes in solution. The devices can be limited in the sense that they can be designed to output purified analytes thatmore » are then further analyzed in separate machines or they can include additional channels through which purified analytes can be further processed and analyzed.« less

  7. A simple method to produce 2D and 3D microfluidic paper-based analytical devices for clinical analysis.

    PubMed

    de Oliveira, Ricardo A G; Camargo, Fiamma; Pesquero, Naira C; Faria, Ronaldo Censi

    2017-03-08

    This paper describes the fabrication of 2D and 3D microfluidic paper-based analytical devices (μPADs) for monitoring glucose, total protein, and nitrite in blood serum and artificial urine. A new method of cutting and sealing filter paper to construct μPADs was demonstrated. Using an inexpensive home cutter printer soft cellulose-based filter paper was easily and precisely cut to produce pattern hydrophilic microchannels. 2D and 3D μPADs were designed with three detection zones each for the colorimetric detection of the analytes. A small volume of samples was added to the μPADs, which was photographed after 15 min using a digital camera. Both μPADs presented an excellent analytical performance for all analytes. The 2D device was applied in artificial urine samples and reached limits of detection (LODs) of 0.54 mM, 5.19 μM, and 2.34 μM for glucose, protein, and nitrite, respectively. The corresponding LODs of the 3D device applied for detecting the same analytes in artificial blood serum were 0.44 mM, 1.26 μM, and 4.35 μM. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Quantitative PCR for genetic markers of human fecal pollution

    EPA Science Inventory

    Assessment of health risk and fecal bacteria loads associated with human fecal pollution requires reliable host-specific analytical methods and a rapid quantification approach. We report the development of quantitative PCR assays for enumeration of two recently described hum...

  9. EPA/ORD NATIONAL EXPOSURE RESEARCH LABORATORY MEASUREMENT SCIENCE SUPPORT FOR HOMELAND SECURITY

    EPA Science Inventory

    This product describes the National Exposure Research Laboratory research and development support for homeland security through the proposed National Exposure Measurements Center (NEMC). Key NEMC functional areas depicted in this poster are: standardized analytical method develo...

  10. Analytical method for the simultaneous determination of polyfunctional amines used as monomers in the manufacture of food packaging materials.

    PubMed

    Paseiro-Cerrato, R; de Quirós, A Rodríguez-Bernaldo; Sendón, Raquel; Bustos, Juana; Ruíz, E; Cruz, J M; Paseiro-Losada, P

    2011-10-07

    This paper describes the development of a multi-analyte method for the determination of polyfunctional amines commonly used as monomers in the manufacture of food contact materials. Amines were analyzed by high-performance-liquid chromatography with diode-array detection (HPLC-DAD) after derivatization with dansyl chloride. The chromatographic analysis and the derivatization conditions were optimized. The proposed method was validated in terms of linearity, limits of detection and repeatabilities. The method showed an excellent sensitivity (LOD≤0.05 μg/mL) and appropriate repeatabilites (RSD (n=7)≤5%)). LC-MS/MS was used as a confirmatory technique. The stability of the amines in five food simulants (distilled water, 3% acetic acid, 10% ethanol, 50% ethanol and olive oil) under the most common testing conditions (10 days at 40 °C) was also studied. Results showed that amines had an acceptable stability in aqueous simulants but in the olive oil a loss of 100% was observed for all analytes. Copyright © 2011. Published by Elsevier B.V.

  11. An Analytical Design Method for a Regenerative Braking Control System for DC-electrified Railway Systems under Light Load Conditions

    NASA Astrophysics Data System (ADS)

    Saito, Tatsuhito; Kondo, Keiichiro; Koseki, Takafumi

    A DC-electrified railway system that is fed by diode rectifiers at a substation is unable to return the electric power to an AC grid. Accordingly, the braking cars have to restrict regenerative braking power when the power consumption of the powering cars is not sufficient. However, the characteristics of a DC-electrified railway system, including the powering cars, is not known, and a mathematical model for designing a controller has not been established yet. Hence, the object of this study is to obtain the mathematical model for an analytical design method of the regenerative braking control system. In the first part of this paper, the static characteristics of this system are presented to show the position of the equilibrium point. The linearization of this system at the equilibrium point is then performed to describe the dynamic characteristics of the system. An analytical design method is then proposed on the basis of these characteristics. The proposed design method is verified by experimental tests with a 1kW class miniature model, and numerical simulations.

  12. Current Protocols in Pharmacology

    PubMed Central

    2016-01-01

    Determination of drug or drug metabolite concentrations in biological samples, particularly in serum or plasma, is fundamental to describing the relationships between administered dose, route of administration, and time after dose to the drug concentrations achieved and to the observed effects of the drug. A well-characterized, accurate analytical method is needed, but it must also be established that the analyte concentration in the sample at the time of analysis is the same as the concentration at sample acquisition. Drugs and metabolites may be susceptible to degradation in samples due to metabolism or to physical and chemical processes, resulting in a lower measured concentration than was in the original sample. Careful examination of analyte stability during processing and storage and adjustment of procedures and conditions to maximize that stability are a critical part of method validation for the analysis, and can ensure the accuracy of the measured concentrations. PMID:27960029

  13. Analytic theory of orbit contraction

    NASA Technical Reports Server (NTRS)

    Vinh, N. X.; Longuski, J. M.; Busemann, A.; Culp, R. D.

    1977-01-01

    The motion of a satellite in orbit, subject to atmospheric force and the motion of a reentry vehicle are governed by gravitational and aerodynamic forces. This suggests the derivation of a uniform set of equations applicable to both cases. For the case of satellite motion, by a proper transformation and by the method of averaging, a technique appropriate for long duration flight, the classical nonlinear differential equation describing the contraction of the major axis is derived. A rigorous analytic solution is used to integrate this equation with a high degree of accuracy, using Poincare's method of small parameters and Lagrange's expansion to explicitly express the major axis as a function of the eccentricity. The solution is uniformly valid for moderate and small eccentricities. For highly eccentric orbits, the asymptotic equation is derived directly from the general equation. Numerical solutions were generated to display the accuracy of the analytic theory.

  14. Probabilistic sensitivity analysis incorporating the bootstrap: an example comparing treatments for the eradication of Helicobacter pylori.

    PubMed

    Pasta, D J; Taylor, J L; Henning, J M

    1999-01-01

    Decision-analytic models are frequently used to evaluate the relative costs and benefits of alternative therapeutic strategies for health care. Various types of sensitivity analysis are used to evaluate the uncertainty inherent in the models. Although probabilistic sensitivity analysis is more difficult theoretically and computationally, the results can be much more powerful and useful than deterministic sensitivity analysis. The authors show how a Monte Carlo simulation can be implemented using standard software to perform a probabilistic sensitivity analysis incorporating the bootstrap. The method is applied to a decision-analytic model evaluating the cost-effectiveness of Helicobacter pylori eradication. The necessary steps are straightforward and are described in detail. The use of the bootstrap avoids certain difficulties encountered with theoretical distributions. The probabilistic sensitivity analysis provided insights into the decision-analytic model beyond the traditional base-case and deterministic sensitivity analyses and should become the standard method for assessing sensitivity.

  15. Comparison between cachaça and rum using pattern recognition methods.

    PubMed

    Cardoso, Daniel R; Andrade-Sobrinho, Luiz G; Leite-Neto, Alexandre F; Reche, Roni V; Isique, William D; Ferreira, Marcia M C; Lima-Neto, Benedito S; Franco, Douglas W

    2004-06-02

    The differentiation between cachaça and rum using analytical data referred to alcohols (methanol, propanol, isobutanol, and isopentanol), acetaldehyde, ethyl acetate, organic acids (octanoic acid, decanoic acid, and dodecanoic acid), metals (Al, Ca, Co, Cu, Cr, Fe, Mg, Mn, Ni, Na, and Zn), and polyphenols (protocatechuic acid, sinapaldehyde, syringaldehyde, ellagic acid, syringic acid, gallic acid, (-)-epicatechin, vanillic acid, vanillin, p-coumaric acid, coniferaldehyde, coniferyl alcohol, kaempferol, and quercetin) is described. The organic and metal analyte contents were determined in 18 cachaça and 21 rum samples using chromatographic methods (GC-MS, GC-FID, and HPLC-UV-vis) and inductively coupled plasma atomic emission spectrometry, respectively. The analytical data of the above compounds, when treated by principal component analysis, hierarchical cluster analysis, discriminant analysis, and K-nearest neighbor analysis, provide a very good discrimination between the two classes of beverages.

  16. Characterization and modeling of an advanced flexible thermal protection material for space applications

    NASA Technical Reports Server (NTRS)

    Clayton, Joseph P.; Tinker, Michael L.

    1991-01-01

    This paper describes experimental and analytical characterization of a new flexible thermal protection material known as Tailorable Advanced Blanket Insulation (TABI). This material utilizes a three-dimensional ceramic fabric core structure and an insulation filler. TABI is the leading candidate for use in deployable aeroassisted vehicle designs. Such designs require extensive structural modeling, and the most significant in-plane material properties necessary for model development are measured and analytically verified in this study. Unique test methods are developed for damping measurements. Mathematical models are developed for verification of the experimental modulus and damping data, and finally, transverse properties are described in terms of the inplane properties through use of a 12-dof finite difference model of a simple TABI configuration.

  17. ICCS/ESCCA consensus guidelines to detect GPI-deficient cells in paroxysmal nocturnal hemoglobinuria (PNH) and related disorders part 4 - assay validation and quality assurance.

    PubMed

    Oldaker, Teri; Whitby, Liam; Saber, Maryam; Holden, Jeannine; Wallace, Paul K; Litwin, Virginia

    2018-01-01

    Over the past six years, a diverse group of stakeholders have put forth recommendations regarding the analytical validation of flow cytometric methods and described in detail the differences between cell-based and traditional soluble analyte assay validations. This manuscript is based on these general recommendations as well as the published experience of experts in the area of PNH testing. The goal is to provide practical assay-specific guidelines for the validation of high-sensitivity flow cytometric PNH assays. Examples of the reports and validation data described herein are provided in Supporting Information. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.

  18. Control of flexible beams using a free-free active truss

    NASA Technical Reports Server (NTRS)

    Clark, W. W.; Kimiavi, B.; Robertshaw, H. H.

    1989-01-01

    An analytical and experimental study involving controlling flexible beams using a free-free active truss is presented. This work extends previous work in controlling flexible continua with active trusses which were configured with fixed-free boundary conditions. The following describes the Lagrangian approach used to derive the equations of motion for the active truss and the beams attached to it. A partial-state feedback control law is derived for this system based on a full-state feedback Linear Quadratic Regulator method. The analytical model is examined via numerical simulations and the results are compared to a similar experimental apparatus described herein. The results show that control of a flexible continua is possible with a free-free active truss.

  19. African Primary Care Research: Qualitative data analysis and writing results

    PubMed Central

    Govender, Indiran; Ogunbanjo, Gboyega A.; Mash, Bob

    2014-01-01

    Abstract This article is part of a series on African primary care research and gives practical guidance on qualitative data analysis and the presentation of qualitative findings. After an overview of qualitative methods and analytical approaches, the article focuses particularly on content analysis, using the framework method as an example. The steps of familiarisation, creating a thematic index, indexing, charting, interpretation and confirmation are described. Key concepts with regard to establishing the quality and trustworthiness of data analysis are described. Finally, an approach to the presentation of qualitative findings is given. PMID:26245437

  20. African Primary Care Research: qualitative data analysis and writing results.

    PubMed

    Mabuza, Langalibalele H; Govender, Indiran; Ogunbanjo, Gboyega A; Mash, Bob

    2014-06-05

    This article is part of a series on African primary care research and gives practical guidance on qualitative data analysis and the presentation of qualitative findings. After an overview of qualitative methods and analytical approaches, the article focuses particularly on content analysis, using the framework method as an example. The steps of familiarisation, creating a thematic index, indexing, charting, interpretation and confirmation are described. Key concepts with regard to establishing the quality and trustworthiness of data analysis are described. Finally, an approach to the presentation of qualitative findings is given.

  1. HPLC-DAD-MS identification of bioactive secondary metabolites from Ferula communis roots.

    PubMed

    Arnoldi, Lolita; Ballero, Mauro; Fuzzati, Nicola; Maxia, Andrea; Mercalli, Enrico; Pagni, Luca

    2004-06-01

    A simple HPLC method was developed to distinguish between 'poisonous' and 'non-poisonous' chemotypes of Ferula communis. The method was performed on a C8 reverse phase analytical column using a binary eluent (aqueous TFA 0.01%-TFA 0.01% in acetonitrile) under gradient condition. The two chemotypes showed different fingerprints. The identification of five coumarins and eleven daucane derivatives by HPLC-diode array detection (HPLC-DAD) and HPLC-MS is described. A coumarin, not yet described, was detected. Copyright 2004 Elsevier B.V.

  2. Development of a pressurized liquid extraction-solid-phase extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry method for the quantitative determination of benzoxazolinones and their degradation products in agricultural soil.

    PubMed

    Villagrasa, M; Guillamón, M; Navarro, A; Eljarrat, E; Barceló, D

    2008-02-01

    A new analytical method for the quantitative determination of benzoxazolinones and their degradation products in agricultural soils based on the use of pressurized liquid extraction (PLE) followed by solid-phase extraction (SPE) and then instrumental determination using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) is described. Using this method, the characterization, separation and quantitative detection of a mixture of two benzoxazolinones, benzoxazolin-2-one (BOA) and 6-methoxybenzoxazolin-2-one (MBOA) and their degradation products, 2-aminophenol (APH), N-(2-hydroxyphenyl)malonamic acid (HMPMA), 2-amino-3-H-phenoxazin-3-one (APO), 9-methoxy-2-amino-3-H-phenoxazin-3-one (AMPO), 2-acetylamino-3-H-phenoxazin-3-one (AAPO) and 2-acetylamino-9-methoxy-2-amino-3-H-phenoxazin-3-one (AAMPO) was achieved. The complete LC-ESI-MS-MS precursor-product ion fragmentation pathways for the degradation products of benzoxazolinones are described for the first time. Quantitative analysis was done in the multiple reaction mode using two specific combinations of precursor-product ion transitions for each compound. The optimized method was quality assessed by the measure of parameter as recovery, linearity, sensitivity, repeatability and reproducibility. Recoveries of the analytes ranged from 53 to 123%. The developed method offered improvements to the sensitivity as compared with our previously LC-MS method, with detection limits down to 2.4-21 ng/g of dry weight. This achievement allows us to identify and quantify for the first time degradation products of benzoxazolinones in real agricultural soil samples. Analytes were found in the range of 20.6-149 ng/g dry weight.

  3. Improving Conceptions in Analytical Chemistry: The Central Limit Theorem

    ERIC Educational Resources Information Center

    Rodriguez-Lopez, Margarita; Carrasquillo, Arnaldo, Jr.

    2006-01-01

    This article describes the central limit theorem (CLT) and its relation to analytical chemistry. The pedagogic rational, which argues for teaching the CLT in the analytical chemistry classroom, is discussed. Some analytical chemistry concepts that could be improved through an understanding of the CLT are also described. (Contains 2 figures.)

  4. Analytical solution describing pesticide volatilization from soil affected by a change in surface condition.

    PubMed

    Yates, S R

    2009-01-01

    An analytical solution describing the fate and transport of pesticides applied to soils has been developed. Two pesticide application methods can be simulated: point-source applications, such as idealized shank or a hot-gas injection method, and a more realistic shank-source application method that includes a vertical pesticide distribution in the soil domain due to a soil fracture caused by a shank. The solutions allow determination of the volatilization rate and other information that could be important for understanding fumigant movement and in the development of regulatory permitting conditions. The solutions can be used to characterize differences in emissions relative to changes in the soil degradation rate, surface barrier conditions, application depth, and soil packing. In some cases, simple algebraic expressions are provided that can be used to obtain the total emissions and total soil degradation. The solutions provide a consistent methodology for determining the total emissions and can be used with other information, such as field and laboratory experimental data, to support the development of fumigant regulations. The uses of the models are illustrated by several examples.

  5. Proposed method for determining the thickness of glass in solar collector panels

    NASA Technical Reports Server (NTRS)

    Moore, D. M.

    1980-01-01

    An analytical method was developed for determining the minimum thickness for simply supported, rectangular glass plates subjected to uniform normal pressure environmental loads such as wind, earthquake, snow, and deadweight. The method consists of comparing an analytical prediction of the stress in the glass panel to a glass breakage stress determined from fracture mechanics considerations. Based on extensive analysis using the nonlinear finite element structural analysis program ARGUS, design curves for the structural analysis of simply supported rectangular plates were developed. These curves yield the center deflection, center stress and corner stress as a function of a dimensionless parameter describing the load intensity. A method of estimating the glass breakage stress as a function of a specified failure rate, degree of glass temper, design life, load duration time, and panel size is also presented.

  6. An Overview of the Analysis of Trace Organics in Water.

    ERIC Educational Resources Information Center

    Trussell, Albert R.; Umphres, Mark D.

    1978-01-01

    Summarized are current analytical techniques used to classify, isolate, resolve, identify, and quantify organic compounds present in drinking water. A variety of methods are described, then drawbacks and advantages are listed, and research needs and future trends are noted. (CS)

  7. Positron Emission Tomography: Human Brain Function and Biochemistry.

    ERIC Educational Resources Information Center

    Phelps, Michael E.; Mazziotta, John C.

    1985-01-01

    Describes the method, present status, and application of positron emission tomography (PET), an analytical imaging technique for "in vivo" measurements of the anatomical distribution and rates of specific biochemical reactions. Measurements and image dynamic biochemistry link basic and clinical neurosciences with clinical findings…

  8. River Pollution: Part I.

    ERIC Educational Resources Information Center

    Openshaw, Peter

    1983-01-01

    Describes a unit on river pollution and analytical methods to use in assessing temperature, pH, flow, calcium, chloride, dissolved oxygen, biochemical oxygen demand, dissolved nitrogen, detergents, heavy metals, sewage pollution, conductivity, and sediment cores. Suggests tests to be carried out and discusses significance of results. (JM)

  9. Detection of pyrethroid pesticides and their environmental degradation products in duplicate diet samples

    EPA Science Inventory

    The abstract is for an oral presentation at the Asilomar Conference on Mass Spectrometry: Mass Spectrometry in Environmental Chemistry, Toxicology, and Health. It describes analytical method development and sample results for determination of pyrethroid pesticides and environme...

  10. Addressing the Creationist Challenge.

    ERIC Educational Resources Information Center

    Seaford, H. Wade, Jr.

    1990-01-01

    Describes a method of contrasting "scientific creationism" and evolution, or pseudo-science and science, that was utilized in a freshman seminar at Dickinson College. Discusses how the seminar format fostered analytical thinking, research, and writing skills. Presents responses given by creationist students after the course. (JS)

  11. Supersymmetric quantum mechanics method for the Fokker-Planck equation with applications to protein folding dynamics

    NASA Astrophysics Data System (ADS)

    Polotto, Franciele; Drigo Filho, Elso; Chahine, Jorge; Oliveira, Ronaldo Junio de

    2018-03-01

    This work developed analytical methods to explore the kinetics of the time-dependent probability distributions over thermodynamic free energy profiles of protein folding and compared the results with simulation. The Fokker-Planck equation is mapped onto a Schrödinger-type equation due to the well-known solutions of the latter. Through a semi-analytical description, the supersymmetric quantum mechanics formalism is invoked and the time-dependent probability distributions are obtained with numerical calculations by using the variational method. A coarse-grained structure-based model of the two-state protein Tm CSP was simulated at a Cα level of resolution and the thermodynamics and kinetics were fully characterized. Analytical solutions from non-equilibrium conditions were obtained with the simulated double-well free energy potential and kinetic folding times were calculated. It was found that analytical folding time as a function of temperature agrees, quantitatively, with simulations and experiments from the literature of Tm CSP having the well-known 'U' shape of the Chevron Plots. The simple analytical model developed in this study has a potential to be used by theoreticians and experimentalists willing to explore, quantitatively, rates and the kinetic behavior of their system by informing the thermally activated barrier. The theory developed describes a stochastic process and, therefore, can be applied to a variety of biological as well as condensed-phase two-state systems.

  12. Nonclinical safety biomarkers of drug-induced vascular injury: current status and blueprint for the future.

    PubMed

    Mikaelian, Igor; Cameron, Mark; Dalmas, Deidre A; Enerson, Bradley E; Gonzalez, Raymond J; Guionaud, Silvia; Hoffmann, Peter K; King, Nicholas M P; Lawton, Michael P; Scicchitano, Marshall S; Smith, Holly W; Thomas, Roberta A; Weaver, James L; Zabka, Tanja S

    2014-06-01

    Better biomarkers are needed to identify, characterize, and/or monitor drug-induced vascular injury (DIVI) in nonclinical species and patients. The Predictive Safety Testing Consortium (PSTC), a precompetitive collaboration of pharmaceutical companies and the U.S. Food and Drug Administration (FDA), formed the Vascular Injury Working Group (VIWG) to develop and qualify translatable biomarkers of DIVI. The VIWG focused its research on acute DIVI because early detection for clinical and nonclinical safety monitoring is desirable. The VIWG developed a strategy based on the premise that biomarkers of DIVI in rat would be translatable to humans due to the morphologic similarity of vascular injury between species regardless of mechanism. The histomorphologic lexicon for DIVI in rat defines degenerative and adaptive findings of the vascular endothelium and smooth muscles, and characterizes inflammatory components. We describe the mechanisms of these changes and their associations with candidate biomarkers for which advanced analytical method validation was completed. Further development is recommended for circulating microRNAs, endothelial microparticles, and imaging techniques. Recommendations for sample collection and processing, analytical methods, and confirmation of target localization using immunohistochemistry and in situ hybridization are described. The methods described are anticipated to aid in the identification and qualification of translational biomarkers for DIVI. © 2014 by The Author(s).

  13. Coherent and partially coherent dark hollow beams with rectangular symmetry and paraxial propagation properties

    NASA Astrophysics Data System (ADS)

    Cai, Yangjian; Zhang, Lei

    2006-07-01

    A theoretical model is proposed to describe coherent dark hollow beams (DHBs) with rectangular symmetry. The electric field of a coherent rectangular DHB is expressed as a superposition of a series of the electric field of a finite series of fundamental Gaussian beams. Analytical propagation formulas for a coherent rectangular DHB passing through paraxial optical systems are derived in a tensor form. Furthermore, for the more general case, we propose a theoretical model to describe a partially coherent rectangular DHB. Analytical propagation formulas for a partially coherent rectangular DHB passing through paraxial optical systems are derived. The beam propagation factor (M2 factor) for both coherent and partially coherent rectangular DHBs are studied. Numerical examples are given by using the derived formulas. Our models and method provide an effective way to describe and treat the propagation of coherent and partially coherent rectangular DHBs.

  14. Optimal focusing conditions of lenses using Gaussian beams

    DOE PAGES

    Franco, Juan Manuel; Cywiak, Moisés; Cywiak, David; ...

    2016-04-02

    By using the analytical equations of the propagation of Gaussian beams in which truncation exhibits negligible consequences, we describe a method that uses the value of the focal length of a focusing lens to classify its focusing performance. In this study, we show that for different distances between a laser and a focusing lens there are different planes where best focusing conditions can be obtained and we demonstrate how the value of the focal length impacts the lens focusing properties. To perform the classification we introduce the term delimiting focal length. As the value of the focal length used inmore » wave propagation theory is nominal and difficult to measure accurately, we describe an experimental approach to calculate its value matching our analytical description. Finally, we describe possible applications of the results for characterizing Gaussian sources, for measuring focal lengths and/or alternatively for characterizing piston-like movements.« less

  15. Evolution of microbiological analytical methods for dairy industry needs

    PubMed Central

    Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence

    2014-01-01

    Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry’s needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards. PMID:24570675

  16. Evolution of microbiological analytical methods for dairy industry needs.

    PubMed

    Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence

    2014-01-01

    Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry's needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards.

  17. Statistical analysis of loopy belief propagation in random fields

    NASA Astrophysics Data System (ADS)

    Yasuda, Muneki; Kataoka, Shun; Tanaka, Kazuyuki

    2015-10-01

    Loopy belief propagation (LBP), which is equivalent to the Bethe approximation in statistical mechanics, is a message-passing-type inference method that is widely used to analyze systems based on Markov random fields (MRFs). In this paper, we propose a message-passing-type method to analytically evaluate the quenched average of LBP in random fields by using the replica cluster variation method. The proposed analytical method is applicable to general pairwise MRFs with random fields whose distributions differ from each other and can give the quenched averages of the Bethe free energies over random fields, which are consistent with numerical results. The order of its computational cost is equivalent to that of standard LBP. In the latter part of this paper, we describe the application of the proposed method to Bayesian image restoration, in which we observed that our theoretical results are in good agreement with the numerical results for natural images.

  18. Forced degradation and impurity profiling: recent trends in analytical perspectives.

    PubMed

    Jain, Deepti; Basniwal, Pawan Kumar

    2013-12-01

    This review describes an epigrammatic impression of the recent trends in analytical perspectives of degradation and impurities profiling of pharmaceuticals including active pharmaceutical ingredient (API) as well as drug products during 2008-2012. These recent trends in forced degradation and impurity profiling were discussed on the head of year of publication; columns, matrix (API and dosage forms) and type of elution in chromatography (isocratic and gradient); therapeutic categories of the drug which were used for analysis. It focuses distinctly on comprehensive update of various analytical methods including hyphenated techniques for the identification and quantification of thresholds of impurities and degradants in different pharmaceutical matrices. © 2013 Elsevier B.V. All rights reserved.

  19. Investigation of the feasibility of an analytical method of accounting for the effects of atmospheric drag on satellite motion

    NASA Technical Reports Server (NTRS)

    Bozeman, Robert E.

    1987-01-01

    An analytic technique for accounting for the joint effects of Earth oblateness and atmospheric drag on close-Earth satellites is investigated. The technique is analytic in the sense that explicit solutions to the Lagrange planetary equations are given; consequently, no numerical integrations are required in the solution process. The atmospheric density in the technique described is represented by a rotating spherical exponential model with superposed effects of the oblate atmosphere and the diurnal variations. A computer program implementing the process is discussed and sample output is compared with output from program NSEP (Numerical Satellite Ephemeris Program). NSEP uses a numerical integration technique to account for atmospheric drag effects.

  20. Analysis of the sound field in finite length infinite baffled cylindrical ducts with vibrating walls of finite impedance.

    PubMed

    Shao, Wei; Mechefske, Chris K

    2005-04-01

    This paper describes an analytical model of finite cylindrical ducts with infinite flanges. This model is used to investigate the sound radiation characteristics of the gradient coil system of a magnetic resonance imaging (MRI) scanner. The sound field in the duct satisfies both the boundary conditions at the wall and at the open ends. The vibrating cylindrical wall of the duct is assumed to be the only sound source. Different acoustic conditions for the wall (rigid and absorptive) are used in the simulations. The wave reflection phenomenon at the open ends of the finite duct is described by general radiation impedance. The analytical model is validated by the comparison with its counterpart in a commercial code based on the boundary element method (BEM). The analytical model shows significant advantages over the BEM model with better numerical efficiency and a direct relation between the design parameters and the sound field inside the duct.

  1. Nondestructive assessment of single-span timber bridges using a vibration- based method

    Treesearch

    Xiping Wang; James P. Wacker; Angus M. Morison; John W. Forsman; John R. Erickson; Robert J. Ross

    2005-01-01

    This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...

  2. A research program to reduce interior noise in general aviation airplanes. [test methods and results

    NASA Technical Reports Server (NTRS)

    Roskam, J.; Muirhead, V. U.; Smith, H. W.; Peschier, T. D.; Durenberger, D.; Vandam, K.; Shu, T. C.

    1977-01-01

    Analytical and semi-empirical methods for determining the transmission of sound through isolated panels and predicting panel transmission loss are described. Test results presented include the influence of plate stiffness and mass and the effects of pressurization and vibration damping materials on sound transmission characteristics. Measured and predicted results are presented in tables and graphs.

  3. Determination of Total Solids and Ash in Algal Biomass: Laboratory Analytical Procedure (LAP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Wychen, Stefanie; Laurens, Lieve M. L.

    2016-01-13

    This procedure describes the methods used to determine the amount of moisture or total solids present in a freeze-dried algal biomass sample, as well as the ash content. A traditional convection oven drying procedure is covered for total solids content, and a dry oxidation method at 575 deg. C is covered for ash content.

  4. Analysis of Whiskey by Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography/Mass Spectrometry: An Upper Division Analytical Chemistry Experiment Guided by Green Chemistry

    ERIC Educational Resources Information Center

    Owens, Janel E.; Zimmerman, Laura B.; Gardner, Michael A.; Lowe, Luis E.

    2016-01-01

    Analysis of whiskey samples prepared by a green microextraction technique, dispersive liquid-liquid microextraction (DLLME), before analysis by a qualitative gas chromatography-mass spectrometry (GC/MS) method, is described as a laboratory experiment for an upper division instrumental methods of analysis laboratory course. Here, aroma compounds in…

  5. Computer modeling of a two-junction, monolithic cascade solar cell

    NASA Technical Reports Server (NTRS)

    Lamorte, M. F.; Abbott, D.

    1979-01-01

    The theory and design criteria for monolithic, two-junction cascade solar cells are described. The departure from the conventional solar cell analytical method and the reasons for using the integral form of the continuity equations are briefly discussed. The results of design optimization are presented. The energy conversion efficiency that is predicted for the optimized structure is greater than 30% at 300 K, AMO and one sun. The analytical method predicts device performance characteristics as a function of temperature. The range is restricted to 300 to 600 K. While the analysis is capable of determining most of the physical processes occurring in each of the individual layers, only the more significant device performance characteristics are presented.

  6. Determination of fenoterol in human plasma by HPLC with fluorescence detection after derivatization.

    PubMed

    Meineke, Ingolf; Steinmetz, Hannelore; Kramer, Skaidrit; Gleiter, Christoph H

    2002-06-20

    A new method for the determination of fenoterol is described, which uses HPLC separation with fluorescence detection. Dobutamine is employed as an internal standard. The separation was achieved on a short reversed phase column with a mobile phase consisting of water, acetonitrile and methanol. Prior to chromatography both analytes are derivatized with 9-chloroformyl-carbazole. Isolation of the analytes from plasma is carried out by liquid-liquid extraction into 2-butanol after protein precipitation with acetonitrile. The method is capable of estimating fenoterol concentrations in the sub-nanogram per ml range with sufficient accuracy and precision. The determination of fenoterol can now be carried out in the average laboratory without radiolabelled material.

  7. An analytic approach to sunset diagrams in chiral perturbation theory: Theory and practice

    NASA Astrophysics Data System (ADS)

    Ananthanarayan, B.; Bijnens, Johan; Ghosh, Shayan; Hebbar, Aditya

    2016-12-01

    We demonstrate the use of several code implementations of the Mellin-Barnes method available in the public domain to derive analytic expressions for the sunset diagrams that arise in the two-loop contribution to the pion mass and decay constant in three-flavoured chiral perturbation theory. We also provide results for all possible two mass configurations of the sunset integral, and derive a new one-dimensional integral representation for the one mass sunset integral with arbitrary external momentum. Thoroughly annotated Mathematica notebooks are provided as ancillary files in the Electronic Supplementary Material to this paper, which may serve as pedagogical supplements to the methods described in this paper.

  8. Optimal Medical Equipment Maintenance Service Proposal Decision Support System combining Activity Based Costing (ABC) and the Analytic Hierarchy Process (AHP).

    PubMed

    da Rocha, Leticia; Sloane, Elliot; M Bassani, Jose

    2005-01-01

    This study describes a framework to support the choice of the maintenance service (in-house or third party contract) for each category of medical equipment based on: a) the real medical equipment maintenance management system currently used by the biomedical engineering group of the public health system of the Universidade Estadual de Campinas located in Brazil to control the medical equipment maintenance service, b) the Activity Based Costing (ABC) method, and c) the Analytic Hierarchy Process (AHP) method. Results show the cost and performance related to each type of maintenance service. Decision-makers can use these results to evaluate possible strategies for the categories of equipment.

  9. Mass Spectrometry for Paper-Based Immunoassays: Toward On-Demand Diagnosis.

    PubMed

    Chen, Suming; Wan, Qiongqiong; Badu-Tawiah, Abraham K

    2016-05-25

    Current analytical methods, either point-of-care or centralized detection, are not able to meet recent demands of patient-friendly testing and increased reliability of results. Here, we describe a two-point separation on-demand diagnostic strategy based on a paper-based mass spectrometry immunoassay platform that adopts stable and cleavable ionic probes as mass reporter; these probes make possible sensitive, interruptible, storable, and restorable on-demand detection. In addition, a new touch paper spray method was developed for on-chip, sensitive, and cost-effective analyte detection. This concept is successfully demonstrated via (i) the detection of Plasmodium falciparum histidine-rich protein 2 antigen and (ii) multiplexed and simultaneous detection of cancer antigen 125 and carcinoembryonic antigen.

  10. Weak form implementation of the semi-analytical finite element (SAFE) method for a variety of elastodynamic waveguides

    NASA Astrophysics Data System (ADS)

    Hakoda, Christopher; Lissenden, Clifford; Rose, Joseph L.

    2018-04-01

    Dispersion curves are essential to any guided wave NDE project. The Semi-Analytical Finite Element (SAFE) method has significantly increased the ease by which these curves can be calculated. However, due to misconceptions regarding theory and fragmentation based on different finite-element software, the theory has stagnated, and adoption by researchers who are new to the field has been slow. This paper focuses on the relationship between the SAFE formulation and finite element theory, and the implementation of the SAFE method in a weak form for plates, pipes, layered waveguides/composites, curved waveguides, and arbitrary cross-sections is shown. The benefits of the weak form are briefly described, as is implementation in open-source and commercial finite element software.

  11. An improved method to measure nitrate/nitrite with an NO-selective electrochemical sensor

    PubMed Central

    Boo, Yong Chool; Tressel, Sarah L.; Jo, Hanjoong

    2007-01-01

    Nitric oxide produced from nitric oxide synthase(s) is an important cell signaling molecule in physiology and pathophysiology. In the present study, we describe a very sensitive and convenient analytical method to measure NOx (nitrite plus nitrate) in culture media by employing an ultra-sensitive nitric oxide-selective electrochemical sensor which became commercially available recently. An aliquot of conditioned culture media was first treated with nitrate reductase/NADPH/glucose-6-phosphate dehydrogenase/glucose-6-phosphate to convert nitrate to nitrite quantitatively. The nitrite (that is present originally plus the reduced nitrate) was then reduced to equimolar NO in an acidic iodide bath while NO was being detected by the sensor. This analytical method appears to be very useful to assess basal and stimulated NO release from cultured cells. PMID:17056288

  12. Environmental behavior and analysis of agricultural sulfur.

    PubMed

    Griffith, Corey M; Woodrow, James E; Seiber, James N

    2015-11-01

    Sulfur has been widely used for centuries as a staple for pest and disease management in agriculture. Presently, it is the largest-volume pesticide in use worldwide. This review describes the sources and recovery methods for sulfur, its allotropic forms and properties and its agricultural uses, including development and potential advantages of nanosulfur as a fungicide. Chemical and microbial reactivity, interactions in soil and water and analytical methods for determination in environmental samples and foodstuffs, including inexpensive analytical methods for sulfur residues in wine, beer and other food/beverage substrates, will be reviewed. The toxicology of sulfur towards humans and agriculturally important fungi is included, with some restrictions on use to promote safety. The review concludes with areas for which more research is warranted. © 2015 Society of Chemical Industry.

  13. Computing the optimal path in stochastic dynamical systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauver, Martha; Forgoston, Eric, E-mail: eric.forgoston@montclair.edu; Billings, Lora

    2016-08-15

    In stochastic systems, one is often interested in finding the optimal path that maximizes the probability of escape from a metastable state or of switching between metastable states. Even for simple systems, it may be impossible to find an analytic form of the optimal path, and in high-dimensional systems, this is almost always the case. In this article, we formulate a constructive methodology that is used to compute the optimal path numerically. The method utilizes finite-time Lyapunov exponents, statistical selection criteria, and a Newton-based iterative minimizing scheme. The method is applied to four examples. The first example is a two-dimensionalmore » system that describes a single population with internal noise. This model has an analytical solution for the optimal path. The numerical solution found using our computational method agrees well with the analytical result. The second example is a more complicated four-dimensional system where our numerical method must be used to find the optimal path. The third example, although a seemingly simple two-dimensional system, demonstrates the success of our method in finding the optimal path where other numerical methods are known to fail. In the fourth example, the optimal path lies in six-dimensional space and demonstrates the power of our method in computing paths in higher-dimensional spaces.« less

  14. Nanomaterials-based biosensors for detection of microorganisms and microbial toxins.

    PubMed

    Sutarlie, Laura; Ow, Sian Yang; Su, Xiaodi

    2017-04-01

    Detection of microorganisms and microbial toxins is important for health and safety. Due to their unique physical and chemical properties, nanomaterials have been extensively used to develop biosensors for rapid detection of microorganisms with microbial cells and toxins as target analytes. In this paper, the design principles of nanomaterials-based biosensors for four selected analyte categories (bacteria cells, toxins, mycotoxins, and protozoa cells), closely associated with the target analytes' properties is reviewed. Five signal transducing methods that are less equipment intensive (colorimetric, fluorimetric, surface enhanced Raman scattering, electrochemical, and magnetic relaxometry methods) is described and compared for their sensory performance (in term oflimit of detection, dynamic range, and response time) for all analyte categories. In the end, the suitability of these five sensing principles for on-site or field applications is discussed. With a comprehensive coverage of nanomaterials, design principles, sensing principles, and assessment on the sensory performance and suitability for on-site application, this review offers valuable insight and perspective for designing suitable nanomaterials-based microorganism biosensors for a given application. Copyright © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Big data analytics in healthcare: promise and potential.

    PubMed

    Raghupathi, Wullianallur; Raghupathi, Viju

    2014-01-01

    To describe the promise and potential of big data analytics in healthcare. The paper describes the nascent field of big data analytics in healthcare, discusses the benefits, outlines an architectural framework and methodology, describes examples reported in the literature, briefly discusses the challenges, and offers conclusions. The paper provides a broad overview of big data analytics for healthcare researchers and practitioners. Big data analytics in healthcare is evolving into a promising field for providing insight from very large data sets and improving outcomes while reducing costs. Its potential is great; however there remain challenges to overcome.

  16. MRMPlus: an open source quality control and assessment tool for SRM/MRM assay development.

    PubMed

    Aiyetan, Paul; Thomas, Stefani N; Zhang, Zhen; Zhang, Hui

    2015-12-12

    Selected and multiple reaction monitoring involves monitoring a multiplexed assay of proteotypic peptides and associated transitions in mass spectrometry runs. To describe peptide and associated transitions as stable, quantifiable, and reproducible representatives of proteins of interest, experimental and analytical validation is required. However, inadequate and disparate analytical tools and validation methods predispose assay performance measures to errors and inconsistencies. Implemented as a freely available, open-source tool in the platform independent Java programing language, MRMPlus computes analytical measures as recommended recently by the Clinical Proteomics Tumor Analysis Consortium Assay Development Working Group for "Tier 2" assays - that is, non-clinical assays sufficient enough to measure changes due to both biological and experimental perturbations. Computed measures include; limit of detection, lower limit of quantification, linearity, carry-over, partial validation of specificity, and upper limit of quantification. MRMPlus streamlines assay development analytical workflow and therefore minimizes error predisposition. MRMPlus may also be used for performance estimation for targeted assays not described by the Assay Development Working Group. MRMPlus' source codes and compiled binaries can be freely downloaded from https://bitbucket.org/paiyetan/mrmplusgui and https://bitbucket.org/paiyetan/mrmplusgui/downloads respectively.

  17. Method and means for dynamic measurement of rates of adsorption from solutions

    DOEpatents

    Slomka, B.J.; Buttermore, W.H.

    1992-05-05

    A method and apparatus are described for the dynamic measurement of rates of absorption from solutions. The method has the advantage of avoiding the use of solvent normally used to establish a baseline. The method involves pre-evacuating the adsorbent contained in an adsorbent cell and thereafter rapidly contacting the adsorbent with analytical solution, all without prior exposure of adsorbent to pure solvent. The result is a sharp characteristic adsorption line. 5 figs.

  18. L-shaped piezoelectric motor--part II: analytical modeling.

    PubMed

    Avirovik, Dragan; Karami, M Amin; Inman, Daniel; Priya, Shashank

    2012-01-01

    This paper develops an analytical model for an L-shaped piezoelectric motor. The motor structure has been described in detail in Part I of this study. The coupling of the bending vibration mode of the bimorphs results in an elliptical motion at the tip. The emphasis of this paper is on the development of a precise analytical model which can predict the dynamic behavior of the motor based on its geometry. The motor was first modeled mechanically to identify the natural frequencies and mode shapes of the structure. Next, an electromechanical model of the motor was developed to take into account the piezoelectric effect, and dynamics of L-shaped piezoelectric motor were obtained as a function of voltage and frequency. Finally, the analytical model was validated by comparing it to experiment results and the finite element method (FEM). © 2012 IEEE

  19. Multielement trace determination in SiC powders: assessment of interlaboratory comparisons aimed at the validation and standardization of analytical procedures with direct solid sampling based on ETV ICP OES and DC arc OES.

    PubMed

    Matschat, Ralf; Hassler, Jürgen; Traub, Heike; Dette, Angelika

    2005-12-01

    The members of the committee NMP 264 "Chemical analysis of non-oxidic raw and basic materials" of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to "the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials" by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes.

  20. Class and Home Problems. The Lambert W Function in Ultrafiltration and Diafiltration

    ERIC Educational Resources Information Center

    Foley, Greg

    2016-01-01

    Novel analytical solutions based on the Lambert W function for two problems in ultrafiltration and diafiltration are described. Example problems, suitable for incorporation into an introductory module in unit operations, membrane processing, or numerical methods are provided in each case.

  1. Improved sample management in the cylindrical-tube microelectrophoresis method

    NASA Technical Reports Server (NTRS)

    Smolka, A. J. K.

    1980-01-01

    A modification to an analytical microelectrophoresis system is described that improves the manipulation of the sample particles and fluid. The apparatus modification and improved operational procedure should yield more accurate measurements of particle mobilities and permit less skilled operators to use the apparatus.

  2. CTEPP STANDARD OPERATING PROCEDURE FOR ENTERING OR IMPORTING ELECTRONIC DATA INTO THE CTEPP DATABASE (SOP-4.12)

    EPA Science Inventory

    This SOP described the method used to automatically parse analytical data generated from gas chromatography/mass spectrometry (GC/MS) analyses into CTEPP summary spreadsheets and electronically import the summary spreadsheets into the CTEPP study database.

  3. ANALYSIS OF ALTERNATIVES FOR THE LONG TERM MANAGEMENT OF EXCESS MERCURY

    EPA Science Inventory

    This paper describes a systematic method for comparing options for the long-term management of surplus elemental mercury in the U.S., using the Analytic Hierarchy Process (AHP) as embodied in commercially available Expert Choice software. A limited scope multi-criteria decisionan...

  4. Analysis of Fluorotelomer Alcohols in Soils: Optimization of Extraction and Chromatography

    EPA Science Inventory

    This article describes the development of an analytical method for the determination of fluorotelomer alcohols (FTOHs) in soil. The sensitive and selective determination of the telomer alcohols was performed by extraction with mthyl tert-butyl ether (MTBE) and analysis of the ext...

  5. A Systematic Review of Published Respondent-Driven Sampling Surveys Collecting Behavioral and Biologic Data.

    PubMed

    Johnston, Lisa G; Hakim, Avi J; Dittrich, Samantha; Burnett, Janet; Kim, Evelyn; White, Richard G

    2016-08-01

    Reporting key details of respondent-driven sampling (RDS) survey implementation and analysis is essential for assessing the quality of RDS surveys. RDS is both a recruitment and analytic method and, as such, it is important to adequately describe both aspects in publications. We extracted data from peer-reviewed literature published through September, 2013 that reported collected biological specimens using RDS. We identified 151 eligible peer-reviewed articles describing 222 surveys conducted in seven regions throughout the world. Most published surveys reported basic implementation information such as survey city, country, year, population sampled, interview method, and final sample size. However, many surveys did not report essential methodological and analytical information for assessing RDS survey quality, including number of recruitment sites, seeds at start and end, maximum number of waves, and whether data were adjusted for network size. Understanding the quality of data collection and analysis in RDS is useful for effectively planning public health service delivery and funding priorities.

  6. Utilization management affects health care practices at Walter Reed Army Medical Center: analytical methods applied to decrease length of stay and assign appropriate level of care.

    PubMed

    Phillips, J S; Hamm, C K; Pierce, J R; Kussman, M J

    1999-12-01

    The Department of Defense has embraced utilization management (UM) as an important tool to control and possibly decrease medical costs. Budgetary withholds have been taken by the Office of the Assistant Secretary of Defense (Health Affairs) to encourage the military services to implement UM programs. In response, Walter Reed Army Medical Center implemented a UM program along with other initiatives to effect changes in the delivery of inpatient care. This paper describes this UM program and other organizational initiatives, such as the introduction of new levels of care in an attempt to effect reductions in length of stay and unnecessary admissions. We demonstrate the use of a diversity of databases and analytical methods to quantify improved utilization and management of resources. The initiatives described significantly reduced hospital length of stay and inappropriate inpatient days. Without solid command and clinical leadership support and empowerment of the professional staffs, these significant changes and improvements could not have occurred.

  7. BetaScint{trademark} fiber-optic sensor for detecting strontium-90 and uranium-238 in soil. Innovative technology summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-01

    Accurate measurements of radioactivity in soils contaminated with Strontium-90 (Sr-90) or Uranium-238 (U-238) are essential for many DOE site remediation programs. These crucial measurements determine if excavation and soil removal is necessary, where remediation efforts should be focused, and/or if a site has reached closure. Measuring soil contamination by standard EPA laboratory methods typically takes a week (accelerated analytical test turnaround) or a month (standard analytical test turnaround). The time delay extends to operations involving heavy excavation equipment and associated personnel which are the main costs of remediation. This report describes an application of the BetaScint{trademark} fiber-optic sensor that measuresmore » Sr-90 or U-238 contamination in soil samples on site in about 20 minutes, at a much lower cost than time-consuming laboratory methods, to greatly facilitate remediation. This report describes the technology, its performance, its uses, cost, regulatory and policy issues, and lessons learned.« less

  8. Recent Work in Hybrid Radiation Transport Methods with Applications to Commercial Nuclear Power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulesza, Joel A.

    This talk will begin with an overview of hybrid radiation transport methods followed by a discussion of the author’s work to advance current capabilities. The talk will then describe applications for these methods in commercial nuclear power reactor analyses and techniques for experimental validation. When discussing these analytical and experimental activities, the importance of technical standards such as those created and maintained by ASTM International will be demonstrated.

  9. Errors incurred in profile reconstruction and methods for increasing inversion accuracies for occultation type measurements

    NASA Technical Reports Server (NTRS)

    Gross, S. H.; Pirraglia, J. A.

    1972-01-01

    A method for augmenting the occultation experiment is described for slightly refractive media. This method which permits separation of the components of the gradient of refractivity, appears applicable to most of the planets for a major portion of their atmospheres and ionospheres. The analytic theory is given, and the results of numerical tests with a radially and angularly varying model of an ionosphere are discussed.

  10. The new interactive CESAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, P.B.; Yatabe, M.

    1987-01-01

    In this report the Nuclear Criticality Safety Analytical Methods Resource Center describes a new interactive version of CESAR, a critical experiments storage and retrieval program available on the Nuclear Criticality Information System (NCIS) database at Lawrence Livermore National Laboratory. The original version of CESAR did not include interactive search capabilities. The CESAR database was developed to provide a convenient, readily accessible means of storing and retrieving code input data for the SCALE Criticality Safety Analytical Sequences and the codes comprising those sequences. The database includes data for both cross section preparation and criticality safety calculations. 3 refs., 1 tab.

  11. Stress Analysis of Beams with Shear Deformation of the Flanges

    NASA Technical Reports Server (NTRS)

    Kuhn, Paul

    1937-01-01

    This report discusses the fundamental action of shear deformation of the flanges on the basis of simplifying assumptions. The theory is developed to the point of giving analytical solutions for simple cases of beams and of skin-stringer panels under axial load. Strain-gage tests on a tension panel and on a beam corresponding to these simple cases are described and the results are compared with analytical results. For wing beams, an approximate method of applying the theory is given. As an alternative, the construction of a mechanical analyzer is advocated.

  12. Low thermal flux glass-fiber tubing for cryogenic service

    NASA Technical Reports Server (NTRS)

    Hall, C. A.; Spond, D. E.

    1977-01-01

    This paper describes analytical techniques, fabrication development, and test results for composite tubing that has many applications in aerospace and commercial cryogenic installations. Metal liner fabrication is discussed in detail with attention given to resistance-welded liners, fusion-welded liners, chem-milled tubing liners, joining tube liners and end fittings, heat treatment and leak checks. Composite overwrapping, a second method of tubing fabrication, is also discussed. Test programs and analytical correlation are considered along with composite tubing advantages such as minimum weight, thermal efficiency and safety and reliability.

  13. Use of a Hand-Portable Gas Chromatograph-Toroidal Ion Trap Mass Spectrometer for Self-Chemical Ionization Identification of Degradation Products Related to O-ethyl S-(2-diisopropylaminoethyl) Methyl Phosphonothiolate (VX)

    DTIC Science & Technology

    2011-01-01

    Milwaukee WI). Analytical standards were synthesized for VX degradation product compounds by react- ing 2-(diisopropylamino)ethyl chloride ...Ar at 45 ◦C until the disulfide compound was no longer observed as verified by GC–MS. Methods described by Hook et al. [7] were followed for synthesis ...used was methylene chloride , and the 1.0L volume injected contained 50ng of each analyte. Injector and mass spectrometer transfer line

  14. Semantic Interaction for Visual Analytics: Toward Coupling Cognition and Computation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Endert, Alexander

    2014-07-01

    The dissertation discussed in this article [1] was written in the midst of an era of digitization. The world is becoming increasingly instrumented with sensors, monitoring, and other methods for generating data describing social, physical, and natural phenomena. Thus, data exist with the potential of being analyzed to uncover, or discover, the phenomena from which it was created. However, as the analytic models leveraged to analyze these data continue to increase in complexity and computational capability, how can visualizations and user interaction methodologies adapt and evolve to continue to foster discovery and sensemaking?

  15. Laboratory and quality assurance protocols for the analysis of herbicides in ground water from the Management Systems Evaluation Area, Princeton, Minnesota

    USGS Publications Warehouse

    Larson, S.J.; Capel, P.D.; VanderLoop, A.G.

    1996-01-01

    Laboratory and quality assurance procedures for the analysis of ground-water samples for herbicides at the Management Systems Evaluation Area near Princeton, Minnesota are described. The target herbicides include atrazine, de-ethylatrazine, de-isopropylatrazine, metribuzin, alachlor, 2,6-diethylaniline, and metolachlor. The analytical techniques used are solid-phase extraction, and analysis by gas chromatography with mass-selective detection. Descriptions of cleaning procedures, preparation of standard solutions, isolation of analytes from water, sample transfer methods, instrumental analysis, and data analysis are included.

  16. Retrospective dose assessment for the population living in areas of local fallout from the Semipalatinsk nuclear test site Part I: External exposure.

    PubMed

    Gordeev, Konstantin; Shinkarev, Sergey; Ilyin, Leonid; Bouville, André; Hoshi, Masaharu; Luckyanov, Nickolas; Simon, Steven L

    2006-02-01

    A short analysis of all 111 atmospheric events conducted at the Semipalatinsk Test Site (STS) in 1949-1962 with regard to significant off-site exposure (more than 5 mSv of the effective dose during the first year after the explosion) has been made. The analytical method used to assess external exposure to the residents living in settlements near the STS is described. This method makes use of the archival data on the radiological conditions, including the measurements of exposure rate. Special attention was given to the residents of Dolon and Kanonerka villages exposed mainly as a result of the first test, detonated on August 29, 1949. For the residents of those settlements born in 1935, the dose estimates calculated according to the analytical method, are compared to those derived from the thermoluminescence measurements in bricks and electron paramagnetic resonance measurements in teeth. The methods described in this paper were used for external dose assessment for the cohort members at an initial stage of an ongoing epidemiological study conducted by the U.S. National Cancer Institute in the Republic of Kazakhstan. Recently revised methods and estimates of external exposure for that cohort are given in another paper (Simon et al.) in this conference.

  17. Topiramate: A Review of Analytical Approaches for the Drug Substance, Its Impurities and Pharmaceutical Formulations.

    PubMed

    Pinto, Eduardo Costa; Dolzan, Maressa Danielli; Cabral, Lucio Mendes; Armstrong, Daniel W; de Sousa, Valéria Pereira

    2016-02-01

    An important step during the development of high-performance liquid chromatography (HPLC) methods for quantitative analysis of drugs is choosing the appropriate detector. High sensitivity, reproducibility, stability, wide linear range, compatibility with gradient elution, non-destructive detection of the analyte and response unaffected by changes in the temperature/flow are some of the ideal characteristics of a universal HPLC detector. Topiramate is an anticonvulsant drug mainly used for the treatment of different types of seizures and prophylactic treatment of migraine. Different analytical approaches to quantify topiramate by HPLC have been described because of the lack of chromophoric moieties on its structure, such as derivatization with fluorescent moieties and UV-absorbing moieties, conductivity detection, evaporative light scattering detection, refractive index detection, chemiluminescent nitrogen detection and MS detection. Some methods for the determination of topiramate by capillary electrophoresis and gas chromatography have also been published. This systematic review provides a description of the main analytical methods presented in the literature to analyze topiramate in the drug substance and in pharmaceutical formulations. Each of these methods is briefly discussed, especially considering the detector used with HPLC. In addition, this article presents a review of the data available regarding topiramate stability, degradation products and impurities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Data visualisation in surveillance for injury prevention and control: conceptual bases and case studies.

    PubMed

    Martinez, Ramon; Ordunez, Pedro; Soliz, Patricia N; Ballesteros, Michael F

    2016-04-01

    The complexity of current injury-related health issues demands the usage of diverse and massive data sets for comprehensive analyses, and application of novel methods to communicate data effectively to the public health community, decision-makers and the public. Recent advances in information visualisation, availability of new visual analytic methods and tools, and progress on information technology provide an opportunity for shaping the next generation of injury surveillance. To introduce data visualisation conceptual bases, and propose a visual analytic and visualisation platform in public health surveillance for injury prevention and control. The paper introduces data visualisation conceptual bases, describes a visual analytic and visualisation platform, and presents two real-world case studies illustrating their application in public health surveillance for injury prevention and control. Application of visual analytic and visualisation platform is presented as solution for improved access to heterogeneous data sources, enhance data exploration and analysis, communicate data effectively, and support decision-making. Applications of data visualisation concepts and visual analytic platform could play a key role to shape the next generation of injury surveillance. Visual analytic and visualisation platform could improve data use, the analytic capacity, and ability to effectively communicate findings and key messages. The public health surveillance community is encouraged to identify opportunities to develop and expand its use in injury prevention and control. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. A novel approach for quantitation of nonderivatized sialic acid in protein therapeutics using hydrophilic interaction chromatographic separation and nano quantity analyte detection.

    PubMed

    Chemmalil, Letha; Suravajjala, Sreekanth; See, Kate; Jordan, Eric; Furtado, Marsha; Sun, Chong; Hosselet, Stephen

    2015-01-01

    This paper describes a novel approach for the quantitation of nonderivatized sialic acid in glycoproteins, separated by hydrophilic interaction chromatography, and detection by Nano Quantity Analyte Detector (NQAD). The detection technique of NQAD is based on measuring change in the size of dry aerosol and converting the particle count rate into chromatographic output signal. NQAD detector is suitable for the detection of sialic acid, which lacks sufficiently active chromophore or fluorophore. The water condensation particle counting technology allows the analyte to be enlarged using water vapor to provide highest sensitivity. Derivatization-free analysis of glycoproteins using HPLC/NQAD method with PolyGLYCOPLEX™ amide column is well correlated with HPLC method with precolumn derivatization using 1, 2-diamino-4, 5-methylenedioxybenzene (DMB) as well as the Dionex-based high-pH anion-exchange chromatography (or ion chromatography) with pulsed amperometric detection (HPAEC-PAD). With the elimination of derivatization step, HPLC/NQAD method is more efficient than HPLC/DMB method. HPLC/NQAD method is more reproducible than HPAEC-PAD method as HPAEC-PAD method suffers high variability because of electrode fouling during analysis. Overall, HPLC/NQAD method offers broad linear dynamic range as well as excellent precision, accuracy, repeatability, reliability, and ease of use, with acceptable comparability to the commonly used HPAEC-PAD and HPLC/DMB methods. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  20. Ratio of sequential chromatograms for quantitative analysis and peak deconvolution: Application to standard addition method and process monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Synovec, R.E.; Johnson, E.L.; Bahowick, T.J.

    1990-08-01

    This paper describes a new technique for data analysis in chromatography, based on taking the point-by-point ratio of sequential chromatograms that have been base line corrected. This ratio chromatogram provides a robust means for the identification and the quantitation of analytes. In addition, the appearance of an interferent is made highly visible, even when it coelutes with desired analytes. For quantitative analysis, the region of the ratio chromatogram corresponding to the pure elution of an analyte is identified and is used to calculate a ratio value equal to the ratio of concentrations of the analyte in sequential injections. For themore » ratio value calculation, a variance-weighted average is used, which compensates for the varying signal-to-noise ratio. This ratio value, or equivalently the percent change in concentration, is the basis of a chromatographic standard addition method and an algorithm to monitor analyte concentration in a process stream. In the case of overlapped peaks, a spiking procedure is used to calculate both the original concentration of an analyte and its signal contribution to the original chromatogram. Thus, quantitation and curve resolution may be performed simultaneously, without peak modeling or curve fitting. These concepts are demonstrated by using data from ion chromatography, but the technique should be applicable to all chromatographic techniques.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year (FY) 1993 (October 1992 through September 1993). This annual report is the tenth for the ACL and describes continuing effort on projects, work on new projects, and contributions of the ACL staff to various programs at ANL. The Analytical Chemistry Laboratory is a full-cost-recovery service center, with the primary mission of providing a broad range of analytical chemistry support services to the scientific and engineering programs at ANL. The ACL also has research programs in analyticalmore » chemistry, conducts instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL handles a wide range of analytical problems. Some routine or standard analyses are done, but it is common for the Argonne programs to generate unique problems that require development or modification of methods and adaption of techniques to obtain useful analytical data. The ACL is administratively within the Chemical Technology Division (CMT), its principal ANL client, but provides technical support for many of the technical divisions and programs at ANL. The ACL has four technical groups--Chemical Analysis, Instrumental Analysis, Organic Analysis, and Environmental Analysis--which together include about 45 technical staff members. Talents and interests of staff members cross the group lines, as do many projects within the ACL.« less

  2. Analytical model for advective-dispersive transport involving flexible boundary inputs, initial distributions and zero-order productions

    NASA Astrophysics Data System (ADS)

    Chen, Jui-Sheng; Li, Loretta Y.; Lai, Keng-Hsin; Liang, Ching-Ping

    2017-11-01

    A novel solution method is presented which leads to an analytical model for the advective-dispersive transport in a semi-infinite domain involving a wide spectrum of boundary inputs, initial distributions, and zero-order productions. The novel solution method applies the Laplace transform in combination with the generalized integral transform technique (GITT) to obtain the generalized analytical solution. Based on this generalized analytical expression, we derive a comprehensive set of special-case solutions for some time-dependent boundary distributions and zero-order productions, described by the Dirac delta, constant, Heaviside, exponentially-decaying, or periodically sinusoidal functions as well as some position-dependent initial conditions and zero-order productions specified by the Dirac delta, constant, Heaviside, or exponentially-decaying functions. The developed solutions are tested against an analytical solution from the literature. The excellent agreement between the analytical solutions confirms that the new model can serve as an effective tool for investigating transport behaviors under different scenarios. Several examples of applications, are given to explore transport behaviors which are rarely noted in the literature. The results show that the concentration waves resulting from the periodically sinusoidal input are sensitive to dispersion coefficient. The implication of this new finding is that a tracer test with a periodic input may provide additional information when for identifying the dispersion coefficients. Moreover, the solution strategy presented in this study can be extended to derive analytical models for handling more complicated problems of solute transport in multi-dimensional media subjected to sequential decay chain reactions, for which analytical solutions are not currently available.

  3. The analytical and numerical approaches to the theory of the Moon's librations: Modern analysis and results

    NASA Astrophysics Data System (ADS)

    Petrova, N.; Zagidullin, A.; Nefedyev, Y.; Kosulin, V.; Andreev, A.

    2017-11-01

    Observing physical librations of celestial bodies and the Moon represents one of the astronomical methods of remotely assessing the internal structure of a celestial body without conducting expensive space experiments. The paper contains a review of recent advances in studying the Moon's structure using various methods of obtaining and applying the lunar physical librations (LPhL) data. In this article LPhL simulation methods of assessing viscoelastic and dissipative properties of the lunar body and lunar core parameters, whose existence has been recently confirmed during the seismic data reprocessing of ;Apollo; space mission, are described. Much attention is paid to physical interpretation of the free librations phenomenon and the methods for its determination. In the paper the practical application of the most accurate analytical LPhL tables (Rambaux and Williams, 2011) is discussed. The tables were built on the basis of complex analytical processing of the residual differences obtained when comparing long-term series of laser observations with the numerical ephemeris DE421. In the paper an efficiency analysis of two approaches to LPhL theory is conducted: the numerical and the analytical ones. It has been shown that in lunar investigation both approaches complement each other in various aspects: the numerical approach provides high accuracy of the theory, which is required for the proper processing of modern observations, the analytical approach allows to comprehend the essence of the phenomena in the lunar rotation, predict and interpret new effects in the observations of lunar body and lunar core parameters.

  4. Phonon dispersion on Ag (100) surface: A modified analytic embedded atom method study

    NASA Astrophysics Data System (ADS)

    Xiao-Jun, Zhang; Chang-Le, Chen

    2016-01-01

    Within the harmonic approximation, the analytic expression of the dynamical matrix is derived based on the modified analytic embedded atom method (MAEAM) and the dynamics theory of surface lattice. The surface phonon dispersions along three major symmetry directions , and X¯M¯ are calculated for the clean Ag (100) surface by using our derived formulas. We then discuss the polarization and localization of surface modes at points X¯ and M¯ by plotting the squared polarization vectors as a function of the layer index. The phonon frequencies of the surface modes calculated by MAEAM are compared with the available experimental and other theoretical data. It is found that the present results are generally in agreement with the referenced experimental or theoretical results, with a maximum deviation of 10.4%. The agreement shows that the modified analytic embedded atom method is a reasonable many-body potential model to quickly describe the surface lattice vibration. It also lays a significant foundation for studying the surface lattice vibration in other metals. Project supported by the National Natural Science Foundation of China (Grant Nos. 61471301 and 61078057), the Scientific Research Program Funded by Shaanxi Provincial Education Department, China (Grant No. 14JK1301), and the Specialized Research Fund for the Doctoral Program of Higher Education, China (Grant No. 20126102110045).

  5. Evaluation of strength and failure of brittle rock containing initial cracks under lithospheric conditions

    NASA Astrophysics Data System (ADS)

    Li, Xiaozhao; Qi, Chengzhi; Shao, Zhushan; Ma, Chao

    2018-02-01

    Natural brittle rock contains numerous randomly distributed microcracks. Crack initiation, growth, and coalescence play a predominant role in evaluation for the strength and failure of brittle rocks. A new analytical method is proposed to predict the strength and failure of brittle rocks containing initial microcracks. The formulation of this method is based on an improved wing crack model and a suggested micro-macro relation. In this improved wing crack model, the parameter of crack angle is especially introduced as a variable, and the analytical stress-crack relation considering crack angle effect is obtained. Coupling the proposed stress-crack relation and the suggested micro-macro relation describing the relation between crack growth and axial strain, the stress-strain constitutive relation is obtained to predict the rock strength and failure. Considering different initial microcrack sizes, friction coefficients and confining pressures, effects of crack angle on tensile wedge force acting on initial crack interface are studied, and effects of crack angle on stress-strain constitutive relation of rocks are also analyzed. The strength and crack initiation stress under different crack angles are discussed, and the value of most disadvantaged angle triggering crack initiation and rock failure is founded. The analytical results are similar to the published study results. Rationality of this proposed analytical method is verified.

  6. Official Methods for the Determination of Minerals and Trace Elements in Infant Formula and Milk Products: A Review.

    PubMed

    Poitevin, Eric

    2016-01-01

    The minerals and trace elements that account for about 4% of total human body mass serve as materials and regulators in numerous biological activities in body structure building. Infant formula and milk products are important sources of endogenic and added minerals and trace elements and hence, must comply with regulatory as well as nutritional and safety requirements. In addition, reliable analytical data are necessary to support product content and innovation, health claims, or declaration and specific safety issues. Adequate analytical platforms and methods must be implemented to demonstrate both the compliance and safety assessment of all declared and regulated minerals and trace elements, especially trace-element contaminant surveillance. The first part of this paper presents general information on the mineral composition of infant formula and milk products and their regulatory status. In the second part, a survey describes the main techniques and related current official methods determining minerals and trace elements in infant formula and milk products applied for by various international organizations (AOAC INTERNATIONAL, the International Organization for Standardization, the International Dairy Federation, and the European Committe for Standardization). The third part summarizes method officialization activities by Stakeholder Panels on Infant Formula and Adult Nutritionals and Stakeholder Panel on Strategic Food Analytical Methods. The final part covers a general discussion focusing on analytical gaps and future trends in inorganic analysis that have been applied for in infant formula and milk-based products.

  7. LC-MS/MS methods for albendazole analysis in feed and its metabolite residues in fish fillet and a leaching study in feed after an alternative procedure for drug incorporation.

    PubMed

    Busatto, Zenaís; da Silva, Agnaldo Fernando Baldo; de Freitas, Osvaldo; Paschoal, Jonas Augusto Rizzato

    2017-04-01

    This paper describes the development of analytical methods for the quantification of albendazole (ABZ) in fish feed and ABZ and its main known metabolites (albendazole sulfoxide, albendazole sulfone and albendazole aminosulfone) in fish fillet employing LC-MS/MS. In order to assess the reliability of the analytical methods, evaluation was undertaken as recommended by related guides proposed by the Brazilian Ministry of Agriculture for analytical method validation. The calibration curve for ABZ quantification in feed showed adequate linearity (r > 0.99), precision (CV < 1.03%) and trueness ranging from 99% to 101%. The method for ABZ residues in fish fillet involving the QuEChERS technique for sample extraction had adequate linearity (r > 0.99) for all analytes, precision (CV < 13%) and trueness around 100%, with CCα < 122 ng g - 1 and CCβ < 145 ng g - 1 . Besides, by aiming to avoid the risk of ABZ leaching from feed into the aquatic environment during fish medication via the oral route, a promising procedure for drug incorporation in the feed involving coating feed pellets with ethyl cellulose polymer containing ABZ was also evaluated. The medicated feed had good homogeneity (CV < 3%) and a lower release of ABZ (< 0.2%) from feed to water when the medicated feed stayed in the water for up to 15 min.

  8. A SIMPLE, EFFICIENT SOLUTION OF FLUX-PROFILE RELATIONSHIPS IN THE ATMOSPHERIC SURFACE LAYER

    EPA Science Inventory

    This note describes a simple scheme for analytical estimation of the surface layer similarity functions from state variables. What distinguishes this note from the many previous papers on this topic is that this method is specifically targeted for numerical models where simplici...

  9. Wildland Fire Prevention: Today, Intuition--Tomorrow, Management

    Treesearch

    Albert J. Simard; Linda R. Donoghue

    1987-01-01

    Describes, from a historical perspective, methods used to characterize fire prevention problems and evaluate prevention programs and discusses past research efforts to bolster these analytical and management efforts. Highlights research on the sociological perspectives of the wildfire problem and on quantitative fire occurrence prediction and program evaluation systems...

  10. DISSOLVED OXYGEN AND METHANE IN WATER BY A GC HEADSPACE EQUILIBRATION TECHNIQUE

    EPA Science Inventory

    An analytical procedure is described for the determination of dissolved oxygen and methane in groundwater samples. The method consists of generating a helium gas headspace in a water filled bottle, and analysis of the headspace by gas chromatography. Other permanent gases such as...

  11. Child Development in Developing Countries: Introduction and Methods

    ERIC Educational Resources Information Center

    Bornstein, Marc H.; Britto, Pia Rebello; Nonoyama-Tarumi, Yuko; Ota, Yumiko; Petrovic, Oliver; Putnick, Diane L.

    2012-01-01

    The Multiple Indicator Cluster Survey (MICS) is a nationally representative, internationally comparable household survey implemented to examine protective and risk factors of child development in developing countries around the world. This introduction describes the conceptual framework, nature of the MICS3, and general analytic plan of articles…

  12. Analytical Determination of Fluoride Ion Using Gran's Semi-Antilog Plot.

    ERIC Educational Resources Information Center

    Barnhard, Ralph J.

    1983-01-01

    A quantitative determination for fluoride ion using a commercially available fluoride electrode is described. The procedure referred to as known-addition is employed with the data processed on Gran's Plot Paper. Background information, experimental procedures, and advantages/disadvantages of the method are discussed. (JN)

  13. ANALYSES OF FISH TISSUE BY VACUUM DISTILLATION/GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    The analyses of fish tissue using VD/GC/MS with surrogate-based matrix corrections is described. Techniques for equilibrating surrogate and analyte spikes with a tissue matrix are presented, and equilibrated spiked samples are used to document method performance. The removal of a...

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNamara, B.

    Tandem and stellarator equilibria at high ..beta.. have proved hard to compute and the relaxation methods of Bauer et al., Chodura and Schluter, Hirshman, Strauss, and Pearlstein et al. have been slow to converge. This paper reports an extension of the low-..beta.. analytic method of Pearlstein, Kaiser, and Newcomb to arbitrary ..beta.. for tandem mirrors which converges in 10 to 20 iterations. Extensions of the method to stellarator equilibria are proposed and are very close to the analytic method of Johnson and Greene - the stellarator expansion. Most of the results of all these calculations can be adequately described bymore » low-..beta.. approximations since the MHD stability limits occur at low ..beta... The tandem mirror, having weak curvature and a long central cell, allows finite Larmor radius effects to eliminate most ballooning modes and offers the possibility of really high average ..beta... This is the interest in developing such three-dimensional numerical algorithms.« less

  15. Mathematical modeling and pharmaceutical pricing: analyses used to inform in-licensing and developmental go/No-Go decisions.

    PubMed

    Vernon, John A; Hughen, W Keener; Johnson, Scott J

    2005-05-01

    In the face of significant real healthcare cost inflation, pressured budgets, and ongoing launches of myriad technology of uncertain value, payers have formalized new valuation techniques that represent a barrier to entry for drugs. Cost-effectiveness analysis predominates among these methods, which involves differencing a new technological intervention's marginal costs and benefits with a comparator's, and comparing the resulting ratio to a payer's willingness-to-pay threshold. In this paper we describe how firms are able to model the feasible range of future product prices when making in-licensing and developmental Go/No-Go decisions by considering payers' use of the cost-effectiveness method. We illustrate this analytic method with a simple deterministic example and then incorporate stochastic assumptions using both analytic and simulation methods. Using this strategic approach, firms may reduce product development and in-licensing risk.

  16. HPV Genotyping of Modified General Primer-Amplicons Is More Analytically Sensitive and Specific by Sequencing than by Hybridization

    PubMed Central

    Meisal, Roger; Rounge, Trine Ballestad; Christiansen, Irene Kraus; Eieland, Alexander Kirkeby; Worren, Merete Molton; Molden, Tor Faksvaag; Kommedal, Øyvind; Hovig, Eivind; Leegaard, Truls Michael

    2017-01-01

    Sensitive and specific genotyping of human papillomaviruses (HPVs) is important for population-based surveillance of carcinogenic HPV types and for monitoring vaccine effectiveness. Here we compare HPV genotyping by Next Generation Sequencing (NGS) to an established DNA hybridization method. In DNA isolated from urine, the overall analytical sensitivity of NGS was found to be 22% higher than that of hybridization. NGS was also found to be the most specific method and expanded the detection repertoire beyond the 37 types of the DNA hybridization assay. Furthermore, NGS provided an increased resolution by identifying genetic variants of individual HPV types. The same Modified General Primers (MGP)-amplicon was used in both methods. The NGS method is described in detail to facilitate implementation in the clinical microbiology laboratory and includes suggestions for new standards for detection and calling of types and variants with improved resolution. PMID:28045981

  17. HPV Genotyping of Modified General Primer-Amplicons Is More Analytically Sensitive and Specific by Sequencing than by Hybridization.

    PubMed

    Meisal, Roger; Rounge, Trine Ballestad; Christiansen, Irene Kraus; Eieland, Alexander Kirkeby; Worren, Merete Molton; Molden, Tor Faksvaag; Kommedal, Øyvind; Hovig, Eivind; Leegaard, Truls Michael; Ambur, Ole Herman

    2017-01-01

    Sensitive and specific genotyping of human papillomaviruses (HPVs) is important for population-based surveillance of carcinogenic HPV types and for monitoring vaccine effectiveness. Here we compare HPV genotyping by Next Generation Sequencing (NGS) to an established DNA hybridization method. In DNA isolated from urine, the overall analytical sensitivity of NGS was found to be 22% higher than that of hybridization. NGS was also found to be the most specific method and expanded the detection repertoire beyond the 37 types of the DNA hybridization assay. Furthermore, NGS provided an increased resolution by identifying genetic variants of individual HPV types. The same Modified General Primers (MGP)-amplicon was used in both methods. The NGS method is described in detail to facilitate implementation in the clinical microbiology laboratory and includes suggestions for new standards for detection and calling of types and variants with improved resolution.

  18. Novel HPLC-UV Method for Simultaneous Determination of Fat-soluble Vitamins and Coenzyme Q10 in Medicines and Supplements.

    PubMed

    Temova-Rakuša, Žane; Srečnik, Eva; Roškar, Robert

    2017-09-01

    A precise, accurate and rapid HPLC-UV method for simultaneous determination of fat-soluble vitamins (vitamin D3, E-acetate, K1, β-carotene, A-palmitate) and coenzyme Q10 was developed and validated according to ICH guidelines. Optimal chromatographic separation of the analytes in minimal analysis time (8 min) was achieved on a Luna C18 150 × 4.6 mm column using a mixture of acetonitrile, tetrahydrofuran and water (50:45:5, v/v/v). The described reversed phase HPLC method is the first published for quantification of these five fat-soluble vitamins and coenzyme Q10 within a single chromatographic run. The method was further applied for quantification of the analytes in selected liquid and solid dosage forms, registered as nutritional supplements and prescription medicines, which confirmed its suitability for routine analysis.

  19. Quantification of N-acetyl- and N-glycolylneuraminic acids by a stable isotope dilution assay using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Allevi, Pietro; Femia, Eti Alessandra; Costa, Maria Letizia; Cazzola, Roberta; Anastasia, Mario

    2008-11-28

    The present report describes a method for the quantification of N-acetyl- and N-glycolylneuraminic acids without any derivatization, using their (13)C(3)-isotopologues as internal standards and a C(18) reversed-phase column modified by decylboronic acid which allows for the first time a complete chromatographic separation between the two analytes. The method is based on high-performance liquid chromatographic coupled with electrospray ion-trap mass spectrometry. The limit of quantification of the method is 0.1mg/L (2.0ng on column) for both analytes. The calibration curves are linear for both sialic acids over the range of 0.1-80mg/L (2.0-1600ng on column) with a correlation coefficient greater than 0.997. The proposed method was applied to the quantitative determination of sialic acids released from fetuin as a model of glycoproteins.

  20. Resonance ionization for analytical spectroscopy

    DOEpatents

    Hurst, George S.; Payne, Marvin G.; Wagner, Edward B.

    1976-01-01

    This invention relates to a method for the sensitive and selective analysis of an atomic or molecular component of a gas. According to this method, the desired neutral component is ionized by one or more resonance photon absorptions, and the resultant ions are measured in a sensitive counter. Numerous energy pathways are described for accomplishing the ionization including the use of one or two tunable pulsed dye lasers.

  1. Using Narrative as a Data Source and Analytic Method to Investigate Learning Outside of Traditional School Settings with Diverse Youth

    ERIC Educational Resources Information Center

    Martell, Sandra Toro; Antrop-Gonzalez, Rene

    2008-01-01

    Narrative is used to describe and understand how people construct meaning of their lives and experiences and how they think about their own and others' identities. We examined narrative as both data source and method of analysis for investigating learning in non-traditional school settings with students from diverse socio-economic status and…

  2. Constant gradient PFG sequence and automated cumulant analysis for quantifying dispersion in flow through porous media.

    PubMed

    Scheven, U M

    2013-12-01

    This paper describes a new variant of established stimulated echo pulse sequences, and an analytical method for determining diffusion or dispersion coefficients for Gaussian or non-Gaussian displacement distributions. The unipolar displacement encoding PFGSTE sequence uses trapezoidal gradient pulses of equal amplitude g and equal ramp rates throughout while sampling positive and negative halves of q-space. Usefully, the equal gradient amplitudes and gradient ramp rates help to reduce the impact of experimental artefacts caused by residual amplifier transients, eddy currents, or ferromagnetic hysteresis in components of the NMR magnet. The pulse sequence was validated with measurements of diffusion in water and of dispersion in flow through a packing of spheres. The analytical method introduced here permits the robust determination of the variance of non-Gaussian, dispersive displacement distributions. The noise sensitivity of the analytical method is shown to be negligible, using a demonstration experiment with a non-Gaussian longitudinal displacement distribution, measured on flow through a packing of mono-sized spheres. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. A Study of Driver's Route Choice Behavior Based on Evolutionary Game Theory

    PubMed Central

    Jiang, Xiaowei; Ji, Yanjie; Deng, Wei

    2014-01-01

    This paper proposes a route choice analytic method that embeds cumulative prospect theory in evolutionary game theory to analyze how the drivers adjust their route choice behaviors under the influence of the traffic information. A simulated network with two alternative routes and one variable message sign is built to illustrate the analytic method. We assume that the drivers in the transportation system are bounded rational, and the traffic information they receive is incomplete. An evolutionary game model is constructed to describe the evolutionary process of the drivers' route choice decision-making behaviors. Here we conclude that the traffic information plays an important role in the route choice behavior. The driver's route decision-making process develops towards different evolutionary stable states in accordance with different transportation situations. The analysis results also demonstrate that employing cumulative prospect theory and evolutionary game theory to study the driver's route choice behavior is effective. This analytic method provides an academic support and suggestion for the traffic guidance system, and may optimize the travel efficiency to a certain extent. PMID:25610455

  4. The magnetic particle in a box: Analytic and micromagnetic analysis of probe-localized spin wave modes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adur, Rohan, E-mail: adur@physics.osu.edu; Du, Chunhui; Manuilov, Sergei A.

    2015-05-07

    The dipole field from a probe magnet can be used to localize a discrete spectrum of standing spin wave modes in a continuous ferromagnetic thin film without lithographic modification to the film. Obtaining the resonance field for a localized mode is not trivial due to the effect of the confined and inhomogeneous magnetization precession. We compare the results of micromagnetic and analytic methods to find the resonance field of localized modes in a ferromagnetic thin film, and investigate the accuracy of these methods by comparing with a numerical minimization technique that assumes Bessel function modes with pinned boundary conditions. Wemore » find that the micromagnetic technique, while computationally more intensive, reveals that the true magnetization profiles of localized modes are similar to Bessel functions with gradually decaying dynamic magnetization at the mode edges. We also find that an analytic solution, which is simple to implement and computationally much faster than other methods, accurately describes the resonance field of localized modes when exchange fields are negligible, and demonstrating the accessibility of localized mode analysis.« less

  5. A study of driver's route choice behavior based on evolutionary game theory.

    PubMed

    Jiang, Xiaowei; Ji, Yanjie; Du, Muqing; Deng, Wei

    2014-01-01

    This paper proposes a route choice analytic method that embeds cumulative prospect theory in evolutionary game theory to analyze how the drivers adjust their route choice behaviors under the influence of the traffic information. A simulated network with two alternative routes and one variable message sign is built to illustrate the analytic method. We assume that the drivers in the transportation system are bounded rational, and the traffic information they receive is incomplete. An evolutionary game model is constructed to describe the evolutionary process of the drivers' route choice decision-making behaviors. Here we conclude that the traffic information plays an important role in the route choice behavior. The driver's route decision-making process develops towards different evolutionary stable states in accordance with different transportation situations. The analysis results also demonstrate that employing cumulative prospect theory and evolutionary game theory to study the driver's route choice behavior is effective. This analytic method provides an academic support and suggestion for the traffic guidance system, and may optimize the travel efficiency to a certain extent.

  6. Simultaneous determination of fluoride, chloride, sulfate, phosphate, monofluorophosphate, glycerophosphate, sorbate, and saccharin in gargles by ion chromatography*

    PubMed Central

    Zhang, Yan-zhen; Zhou, Yan-chun; Liu, Li; Zhu, Yan

    2007-01-01

    Simple, reliable and sensitive analytical methods to determine anticariogenic agents, preservatives, and artificial sweeteners contained in commercial gargles are necessary for evaluating their effectiveness, safety, and quality. An ion chromatography (IC) method has been described to analyze simultaneously eight anions including fluoride, chloride, sulfate, phosphate, monofluorophosphate, glycerophosphate (anticariogenic agents), sorbate (a preservative), and saccharin (an artificial sweetener) in gargles. In this IC system, we applied a mobile phased gradient elution with KOH, separation by IonPac AS18 columns, and suppressed conductivity detection. Optimized analytical conditions were further evaluated for accuracy. The relative standard deviations (RSDs) of the inter-day’s retention time and peak area of all species were less than 0.938% and 8.731%, respectively, while RSDs of 5-day retention time and peak area were less than 1.265% and 8.934%, respectively. The correlation coefficients for targeted analytes ranged from 0.999 7 to 1.000 0. The spiked recoveries for the anions were 90%~102.5%. We concluded that the method can be applied for comprehensive evaluation of commercial gargles. PMID:17610331

  7. Simultaneous determination of fluoride, chloride, sulfate, phosphate, monofluorophosphate, glycerophosphate, sorbate, and saccharin in gargles by ion chromatography.

    PubMed

    Zhang, Yan-zhen; Zhou, Yan-chun; Liu, Li; Zhu, Yan

    2007-07-01

    Simple, reliable and sensitive analytical methods to determine anticariogenic agents, preservatives, and artificial sweeteners contained in commercial gargles are necessary for evaluating their effectiveness, safety, and quality. An ion chromatography (IC) method has been described to analyze simultaneously eight anions including fluoride, chloride, sulfate, phosphate, monofluorophosphate, glycerophosphate (anticariogenic agents), sorbate (a preservative), and saccharin (an artificial sweetener) in gargles. In this IC system, we applied a mobile phased gradient elution with KOH, separation by IonPac AS18 columns, and suppressed conductivity detection. Optimized analytical conditions were further evaluated for accuracy. The relative standard deviations (RSDs) of the inter-day's retention time and peak area of all species were less than 0.938% and 8.731%, respectively, while RSDs of 5-day retention time and peak area were less than 1.265% and 8.934%, respectively. The correlation coefficients for targeted analytes ranged from 0.999 7 to 1.000 0. The spiked recoveries for the anions were 90% approximately 102.5%. We concluded that the method can be applied for comprehensive evaluation of commercial gargles.

  8. Method for near-real-time continuous air monitoring of phosgene, hydrogen cyanide, and cyanogen chloride

    NASA Astrophysics Data System (ADS)

    Lattin, Frank G.; Paul, Donald G.

    1996-11-01

    A sorbent-based gas chromatographic method provides continuous quantitative measurement of phosgene, hydrogen cyanide, and cyanogen chloride in ambient air. These compounds are subject to workplace exposure limits as well as regulation under terms of the Chemical Arms Treaty and Title III of the 1990 Clean Air Act amendments. The method was developed for on-sit use in a mobile laboratory during remediation operations. Incorporated into the method are automated multi-level calibrations at time weighted average concentrations, or lower. Gaseous standards are prepared in fused silica lined air sampling canisters, then transferred to the analytical system through dynamic spiking. Precision and accuracy studies performed to validate the method are described. Also described are system deactivation and passivation techniques critical to optimum method performance.

  9. Two Analyte Calibration From The Transient Response Of Potentiometric Sensors Employed With The SIA Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cartas, Raul; Mimendia, Aitor; Valle, Manel del

    2009-05-23

    Calibration models for multi-analyte electronic tongues have been commonly built using a set of sensors, at least one per analyte under study. Complex signals recorded with these systems are formed by the sensors' responses to the analytes of interest plus interferents, from which a multivariate response model is then developed. This work describes a data treatment method for the simultaneous quantification of two species in solution employing the signal from a single sensor. The approach used here takes advantage of the complex information recorded with one electrode's transient after insertion of sample for building the calibration models for both analytes.more » The departure information from the electrode was firstly processed by discrete wavelet for transforming the signals to extract useful information and reduce its length, and then by artificial neural networks for fitting a model. Two different potentiometric sensors were used as study case for simultaneously corroborating the effectiveness of the approach.« less

  10. Chemical Detection and Identification Techniques for Exobiology Flight Experiments

    NASA Technical Reports Server (NTRS)

    Kojiro, Daniel R.; Sheverev, Valery A.; Khromov, Nikolai A.

    2002-01-01

    Exobiology flight experiments require highly sensitive instrumentation for in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical Instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. Advances in technology may be achieved by increasing the amount of information acquired by a given technique with greater analytical capabilities and miniaturization of proven terrestrial technology. We describe here methods to develop analytical instruments for the detection and identification of a wide range of chemical species using Gas Chromatography. These efforts to expand the analytical capabilities of GC technology are focused on the development of detectors for the GC which provide sample identification independent of the GC retention time data. A novel new approach employs Penning Ionization Electron Spectroscopy (PIES).

  11. Determination of target fat-soluble micronutrients in rainbow trout's muscle and liver tissues by liquid chromatography with diode array-tandem mass spectrometry detection.

    PubMed

    Pérez Fernández, Virginia; Ventura, Salvatore; Tomai, Pierpaolo; Curini, Roberta; Gentili, Alessandra

    2017-03-01

    This paper describes an analytical approach, based on LC-diode array detector-MS/MS (LC-DAD-MS/MS), for characterizing the fat-soluble micronutrient fraction in rainbow trout (Oncorhynchus mykiss). Two different procedures were applied to isolate the analytes from liver and muscle tissue: overnight cold saponification to hydrolyze bound forms and to simplify the analysis; matrix solid-phase dispersion to avoid artifacts and to maintain unaltered the naturally occurring forms. Analytes were separated on a C 30 analytical column by using a nonaqueous reversed mobile phase compatible with the atmospheric pressure chemical ionization. Compared to other works, the most relevant advantage of the here illustrated method is the large amount of information obtained with few analytical steps: nine fat-soluble vitamins (3,4-dehydroretinol, retinol, cholecalciferol, ergocalciferol, α-tocopherol, γ-tocopherol, δ-tocopherol, phylloquinone, and menaquinone-4) and eight carotenoids (all-trans-lutein, all-trans-astaxanthin, all-trans-zeaxanthin, all-trans-β-cryptoxanthin, all-trans-canthaxanthin, all-trans-ζ-carotene, all-trans-β-carotene, and all-trans-γ-carotene) were quantified after the method validation, while other untargeted carotenoids were tentatively identified by exploiting the identification power of the LC-DAD-MS/MS hyphenation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Enantioselective Analytical- and Preparative-Scale Separation of Hexabromocyclododecane Stereoisomers Using Packed Column Supercritical Fluid Chromatography.

    PubMed

    Riddell, Nicole; Mullin, Lauren Gayle; van Bavel, Bert; Ericson Jogsten, Ingrid; McAlees, Alan; Brazeau, Allison; Synnott, Scott; Lough, Alan; McCrindle, Robert; Chittim, Brock

    2016-11-10

    Hexabromocyclododecane (HBCDD) is an additive brominated flame retardant which has been listed in Annex A of the Stockholm Convention for elimination of production and use. It has been reported to persist in the environment and has the potential for enantiomer-specific degradation, accumulation, or both, making enantioselective analyses increasingly important. The six main stereoisomers of technical HBCDD (i.e., the (+) and (-) enantiomers of α-, β-, and γ-HBCDD) were separated and isolated for the first time using enantioselective packed column supercritical fluid chromatography (pSFC) separation methods on a preparative scale. Characterization was completed using published chiral liquid chromatography (LC) methods and elution profiles, as well as X-ray crystallography, and the isolated fractions were definitively identified. Additionally, the resolution of the enantiomers, along with two minor components of the technical product (δ- and ε-HBCDD), was investigated on an analytical scale using both LC and pSFC separation techniques, and changes in elution order were highlighted. Baseline separation of all HBCDD enantiomers was achieved by pSFC on an analytical scale using a cellulose-based column. The described method emphasizes the potential associated with pSFC as a green method of isolating and analyzing environmental contaminants of concern.

  13. Determination of residual cell culture media components by MEKC.

    PubMed

    Zhang, Junge; Chakraborty, Utpal; Foley, Joe P

    2009-11-01

    Folic acid, hypoxanthine, mycophenolic acid, nicotinic acid, riboflavin, and xanthine are widely used as cell culture media components in monoclonal antibody manufacturing. These components are subsequently removed during the downstream purification processes. This article describes a single MEKC method that can simultaneously determine all the listed compounds with acceptable LOD and LOQ. All the analytes were successfully separated by MEKC using running buffer containing 40 mM SDS, 20 mM sodium phosphate, and 20 mM sodium borate at pH 9.0. The MEKC method was compared to the corresponding CZE method using the same running buffer containing no SDS. The effect of SDS concentration on separation, the pH of the running buffer, and the detection wavelength were studied and optimal MEKC conditions were established. Good linearity was obtained with correlation coefficients of more than 0.99 for all analytes. Specificity, accuracy, and precision were also evaluated. The recovery was in the range of 89-112%. The precision results were in the range of 1.7-4.8%. The experimentally determined data demonstrated that the MEKC method is applicable to the determination of the six analytes in in-process samples from monoclonal antibody manufacturing processes.

  14. Comparison of FDTD numerical computations and analytical multipole expansion method for plasmonics-active nanosphere dimers.

    PubMed

    Dhawan, Anuj; Norton, Stephen J; Gerhold, Michael D; Vo-Dinh, Tuan

    2009-06-08

    This paper describes a comparative study of finite-difference time-domain (FDTD) and analytical evaluations of electromagnetic fields in the vicinity of dimers of metallic nanospheres of plasmonics-active metals. The results of these two computational methods, to determine electromagnetic field enhancement in the region often referred to as "hot spots" between the two nanospheres forming the dimer, were compared and a strong correlation observed for gold dimers. The analytical evaluation involved the use of the spherical-harmonic addition theorem to relate the multipole expansion coefficients between the two nanospheres. In these evaluations, the spacing between two nanospheres forming the dimer was varied to obtain the effect of nanoparticle spacing on the electromagnetic fields in the regions between the nanostructures. Gold and silver were the metals investigated in our work as they exhibit substantial plasmon resonance properties in the ultraviolet, visible, and near-infrared spectral regimes. The results indicate excellent correlation between the two computational methods, especially for gold nanosphere dimers with only a 5-10% difference between the two methods. The effect of varying the diameters of the nanospheres forming the dimer, on the electromagnetic field enhancement, was also studied.

  15. Development of a temperature gradient focusing method for in situ extraterrestrial biomarker analysis.

    PubMed

    Danger, Grégoire; Ross, David

    2008-08-01

    Scanning temperature gradient focusing (TGF) is a recently described technique for the simultaneous concentration and separation of charged analytes. It allows for high analyte peak capacities and low LODs in microcolumn electrophoretic separations. In this paper, we present the application of scanning TGF for chiral separations of amino acids. Using a mixture of seven carboxyfluorescein succinimidyl ester-labeled amino acids (including five chiral amino acids) which constitute the Mars7 standard, we show that scanning TGF is a very simple and efficient method for chiral separations. The modulation of TGF separation parameters (temperature window, pressure scan rate, temperature range, and chiral selector concentration) allows optimization of peak efficiencies and analyte resolutions. The use of hydroxypropyl-beta-CD at low concentration (1-5 mmol/L) as a chiral selector, with an appropriate pressure scan rate ( -0.25 Pa/s) and with a low temperature range (3-25 degrees C over 1 cm) provided high resolution between enantiomers (Rs >1.5 for each pair of enantiomers) using a short, 4 cm long capillary. With these new results, the scanning TGF method appears to be a viable method for in situ trace biomarker analysis for future missions to Mars or other solar system bodies.

  16. Observability during planetary approach navigation

    NASA Technical Reports Server (NTRS)

    Bishop, Robert H.; Burkhart, P. Daniel; Thurman, Sam W.

    1993-01-01

    The objective of the research is to develop an analytic technique to predict the relative navigation capability of different Earth-based radio navigation measurements. In particular, the problem is to determine the relative ability of geocentric range and Doppler measurements to detect the effects of the target planet gravitational attraction on the spacecraft during the planetary approach and near-encounter mission phases. A complete solution to the two-dimensional problem has been developed. Relatively simple analytic formulas are obtained for range and Doppler measurements which describe the observability content of the measurement data along the approach trajectories. An observability measure is defined which is based on the observability matrix for nonlinear systems. The results show good agreement between the analytic observability analysis and the computational batch processing method.

  17. Design Criteria for Low Profile Flange Calculations

    NASA Technical Reports Server (NTRS)

    Leimbach, K. R.

    1973-01-01

    An analytical method and a design procedure to develop flanged separable pipe connectors are discussed. A previously established algorithm is the basis for calculating low profile flanges. The characteristics and advantages of the low profile flange are analyzed. The use of aluminum, titanium, and plastics for flange materials is described. Mathematical models are developed to show the mechanical properties of various flange configurations. A computer program for determining the structural stability of the flanges is described.

  18. Specifying and calibrating instrumentations for wideband electronic power measurements. [in switching circuits

    NASA Technical Reports Server (NTRS)

    Lesco, D. J.; Weikle, D. H.

    1980-01-01

    The wideband electric power measurement related topics of electronic wattmeter calibration and specification are discussed. Tested calibration techniques are described in detail. Analytical methods used to determine the bandwidth requirements of instrumentation for switching circuit waveforms are presented and illustrated with examples from electric vehicle type applications. Analog multiplier wattmeters, digital wattmeters and calculating digital oscilloscopes are compared. The instrumentation characteristics which are critical to accurate wideband power measurement are described.

  19. Application of advanced control techniques to aircraft propulsion systems

    NASA Technical Reports Server (NTRS)

    Lehtinen, B.

    1984-01-01

    Two programs are described which involve the application of advanced control techniques to the design of engine control algorithms. Multivariable control theory is used in the F100 MVCS (multivariable control synthesis) program to design controls which coordinate the control inputs for improved engine performance. A systematic method for handling a complex control design task is given. Methods of analytical redundancy are aimed at increasing the control system reliability. The F100 DIA (detection, isolation, and accommodation) program, which investigates the uses of software to replace or augment hardware redundancy for certain critical engine sensor, is described.

  20. An analytic-numerical method for the construction of the reference law of operation for a class of mechanical controlled systems

    NASA Astrophysics Data System (ADS)

    Mizhidon, A. D.; Mizhidon, K. A.

    2017-04-01

    An analytic-numerical method for the construction of a reference law of operation for a class of dynamic systems describing vibrations in controlled mechanical systems is proposed. By the reference law of operation of a system, we mean a law of the system motion that satisfies all the requirements for the quality and design features of the system under permanent external disturbances. As disturbances, we consider polyharmonic functions with known amplitudes and frequencies of the harmonics but unknown initial phases. For constructing the reference law of motion, an auxiliary optimal control problem is solved in which the cost function depends on a weighting coefficient. The choice of the weighting coefficient ensures the design of the reference law. Theoretical foundations of the proposed method are given.

  1. Reaction wheel low-speed compensation using a dither signal

    NASA Astrophysics Data System (ADS)

    Stetson, John B., Jr.

    1993-08-01

    A method for improving low-speed reaction wheel performance on a three-axis controlled spacecraft is presented. The method combines a constant amplitude offset with an unbiased, oscillating dither to harmonically linearize rolling solid friction dynamics. The complete, nonlinear rolling solid friction dynamics using an analytic modification to the experimentally verified Dahl solid friction model were analyzed using the dual-input describing function method to assess the benefits of dither compensation. The modified analytic solid friction model was experimentally verified with a small dc servomotor actuated reaction wheel assembly. Using dither compensation abrupt static friction disturbances are eliminated and near linear behavior through zero rate can be achieved. Simulated vehicle response to a wheel rate reversal shows that when the dither and offset compensation is used, elastic modes are not significantly excited, and the uncompensated attitude error reduces by 34:1.

  2. Validation of an isotope dilution, ICP-MS method based on internal mass bias correction for the determination of trace concentrations of Hg in sediment cores.

    PubMed

    Ciceri, E; Recchia, S; Dossi, C; Yang, L; Sturgeon, R E

    2008-01-15

    The development and validation of a method for the determination of mercury in sediments using a sector field inductively coupled plasma mass spectrometer (SF-ICP-MS) for detection is described. The utilization of isotope dilution (ID) calibration is shown to solve analytical problems related to matrix composition. Mass bias is corrected using an internal mass bias correction technique, validated against the traditional standard bracketing method. The overall analytical protocol is validated against NRCC PACS-2 marine sediment CRM. The estimated limit of detection is 12ng/g. The proposed procedure was applied to the analysis of a real sediment core sampled to a depth of 160m in Lake Como, where Hg concentrations ranged from 66 to 750ng/g.

  3. Graphite nanocomposites sensor for multiplex detection of antioxidants in food.

    PubMed

    Ng, Khan Loon; Tan, Guan Huat; Khor, Sook Mei

    2017-12-15

    Butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), and tert-butylhydroquinone (TBHQ) are synthetic antioxidants used in the food industry. Herein, we describe the development of a novel graphite nanocomposite-based electrochemical sensor for the multiplex detection and measurement of BHA, BHT, and TBHQ levels in complex food samples using a linear sweep voltammetry technique. Moreover, our newly established analytical method exhibited good sensitivity, limit of detection, limit of quantitation, and selectivity. The accuracy and reliability of analytical results were challenged by method validation and comparison with the results of the liquid chromatography method, where a linear correlation of more than 0.99 was achieved. The addition of sodium dodecyl sulfate as supporting additive further enhanced the LSV response (anodic peak current, I pa ) of BHA and BHT by 2- and 20-times, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Description and comparison of selected models for hydrologic analysis of ground-water flow, St Joseph River basin, Indiana

    USGS Publications Warehouse

    Peters, J.G.

    1987-01-01

    The Indiana Department of Natural Resources (IDNR) is developing water-management policies designed to assess the effects of irrigation and other water uses on water supply in the basin. In support of this effort, the USGS, in cooperation with IDNR, began a study to evaluate appropriate methods for analyzing the effects of pumping on ground-water levels and streamflow in the basin 's glacial aquifer systems. Four analytical models describe drawdown for a nonleaky, confined aquifer and fully penetrating well; a leaky, confined aquifer and fully penetrating well; a leaky, confined aquifer and partially penetrating well; and an unconfined aquifer and partially penetrating well. Analytical equations, simplifying assumptions, and methods of application are described for each model. In addition to these four models, several other analytical models were used to predict the effects of ground-water pumping on water levels in the aquifer and on streamflow in local areas with up to two pumping wells. Analytical models for a variety of other hydrogeologic conditions are cited. A digital ground-water flow model was used to describe how a numerical model can be applied to a glacial aquifer system. The numerical model was used to predict the effects of six pumping plans in 46.5 sq mi area with as many as 150 wells. Water budgets for the six pumping plans were used to estimate the effect of pumping on streamflow reduction. Results of the analytical and numerical models indicate that, in general, the glacial aquifers in the basin are highly permeable. Radial hydraulic conductivity calculated by the analytical models ranged from 280 to 600 ft/day, compared to 210 and 360 ft/day used in the numerical model. Maximum seasonal pumping for irrigation produced maximum calculated drawdown of only one-fourth of available drawdown and reduced streamflow by as much as 21%. Analytical models are useful in estimating aquifer properties and predicting local effects of pumping in areas with simple lithology and boundary conditions and with few pumping wells. Numerical models are useful in regional areas with complex hydrogeology with many pumping wells and provide detailed water budgets useful for estimating the sources of water in pumping simulations. Numerical models are useful in constructing flow nets. The choice of which type of model to use is also based on the nature and scope of questions to be answered and on the degree of accuracy required. (Author 's abstract)

  5. Analytical design of a hyper-spectral imaging spectrometer utilizing a convex grating

    NASA Astrophysics Data System (ADS)

    Kim, Seo H.; Kong, Hong J.; Ku, Hana; Lee, Jun H.

    2012-09-01

    This paper describes about the new design method for hyper-spectral Imaging spectrometers utilizing convex grating. Hyper-spectral imaging systems are power tools in the field of remote sensing. HSI systems collect at least 100 spectral bands of 10~20 nm width. Because the spectral signature is different and induced unique for each material, it should be possible to discriminate between one material and another based on difference in spectral signature of material. I mathematically analyzed parameters for the intellectual initial design. Main concept of this is the derivative of "ring of minimum aberration without vignetting". This work is a kind of analytical design of an Offner imaging spectrometer. Also, several experiment methods will be contrived to evaluate the performance of imaging spectrometer.

  6. GraphPrints: Towards a Graph Analytic Method for Network Anomaly Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harshaw, Chris R; Bridges, Robert A; Iannacone, Michael D

    This paper introduces a novel graph-analytic approach for detecting anomalies in network flow data called \\textit{GraphPrints}. Building on foundational network-mining techniques, our method represents time slices of traffic as a graph, then counts graphlets\\textemdash small induced subgraphs that describe local topology. By performing outlier detection on the sequence of graphlet counts, anomalous intervals of traffic are identified, and furthermore, individual IPs experiencing abnormal behavior are singled-out. Initial testing of GraphPrints is performed on real network data with an implanted anomaly. Evaluation shows false positive rates bounded by 2.84\\% at the time-interval level, and 0.05\\% at the IP-level with 100\\% truemore » positive rates at both.« less

  7. Accounting for Uncertainty in Decision Analytic Models Using Rank Preserving Structural Failure Time Modeling: Application to Parametric Survival Models.

    PubMed

    Bennett, Iain; Paracha, Noman; Abrams, Keith; Ray, Joshua

    2018-01-01

    Rank Preserving Structural Failure Time models are one of the most commonly used statistical methods to adjust for treatment switching in oncology clinical trials. The method is often applied in a decision analytic model without appropriately accounting for additional uncertainty when determining the allocation of health care resources. The aim of the study is to describe novel approaches to adequately account for uncertainty when using a Rank Preserving Structural Failure Time model in a decision analytic model. Using two examples, we tested and compared the performance of the novel Test-based method with the resampling bootstrap method and with the conventional approach of no adjustment. In the first example, we simulated life expectancy using a simple decision analytic model based on a hypothetical oncology trial with treatment switching. In the second example, we applied the adjustment method on published data when no individual patient data were available. Mean estimates of overall and incremental life expectancy were similar across methods. However, the bootstrapped and test-based estimates consistently produced greater estimates of uncertainty compared with the estimate without any adjustment applied. Similar results were observed when using the test based approach on a published data showing that failing to adjust for uncertainty led to smaller confidence intervals. Both the bootstrapping and test-based approaches provide a solution to appropriately incorporate uncertainty, with the benefit that the latter can implemented by researchers in the absence of individual patient data. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  8. On Nonlinear Combustion Instability in Liquid Propellant Rocket Motors

    NASA Technical Reports Server (NTRS)

    Sims, J. D. (Technical Monitor); Flandro, Gary A.; Majdalani, Joseph; Sims, Joseph D.

    2004-01-01

    All liquid propellant rocket instability calculations in current use have limited value in the predictive sense and serve mainly as a correlating framework for the available data sets. The well-known n-t model first introduced by Crocco and Cheng in 1956 is still used as the primary analytical tool of this type. A multitude of attempts to establish practical analytical methods have achieved only limited success. These methods usually produce only stability boundary maps that are of little use in making critical design decisions in new motor development programs. Recent progress in understanding the mechanisms of combustion instability in solid propellant rockets"' provides a firm foundation for a new approach to prediction, diagnosis, and correction of the closely related problems in liquid motor instability. For predictive tools to be useful in the motor design process, they must have the capability to accurately determine: 1) time evolution of the pressure oscillations and limit amplitude, 2) critical triggering pulse amplitude, and 3) unsteady heat transfer rates at injector surfaces and chamber walls. The method described in this paper relates these critical motor characteristics directly to system design parameters. Inclusion of mechanisms such as wave steepening, vorticity production and transport, and unsteady detonation wave phenomena greatly enhance the representation of key features of motor chamber oscillatory behavior. The basic theoretical model is described and preliminary computations are compared to experimental data. A plan to develop the new predictive method into a comprehensive analysis tool is also described.

  9. Online Fan Fiction, Global Identities, and Imagination

    ERIC Educational Resources Information Center

    Black, Rebecca W.

    2009-01-01

    Based on longitudinal data from a three year ethnographic study, this article uses discourse analytic methods to explore the literacy and social practices of three adolescent English language learners writing in an online fan fiction community. Theoretical constructs within globalization and literacy studies are used to describe the influences of…

  10. Decision making in prioritization of required operational capabilities

    NASA Astrophysics Data System (ADS)

    Andreeva, P.; Karev, M.; Kovacheva, Ts.

    2015-10-01

    The paper describes an expert heuristic approach to prioritization of required operational capabilities in the field of defense. Based on expert assessment and by application of the method of Analytical Hierarchical Process, a methodology for their prioritization has been developed. It has been applied to practical simulation decision making games.

  11. Functional Communication Training: A Contemporary Behavior Analytic Intervention for Problem Behaviors.

    ERIC Educational Resources Information Center

    Durand, V. Mark; Merges, Eileen

    2001-01-01

    This article describes functional communication training (FCT) with students who have autism. FCT involves teaching alternative communication strategies to replace problem behaviors. The article reviews the conditions under which this intervention is successful and compares the method with other behavioral approaches. It concludes that functional…

  12. Predicting Nursing Facility Transition Candidates Using AID: A Case Study

    ERIC Educational Resources Information Center

    James, Mary L.; Wiley, Elizabeth; Fries, Brant E.

    2007-01-01

    Purpose: Although the nursing facility transition literature is growing, little research has analyzed the characteristics of individuals so assisted or compared participants to those who remain institutionalized. This article describes an analytic method that researchers can apply to address these knowledge gaps, using the Arkansas Passages…

  13. ANALYSIS OF THE ENANTIOMERS OF CHIRAL PESTICIDES AND OTHER POLLUTANTS IN ENVIRONMENTAL SAMPLES BY CAPILLARY ELECTROPHORESIS

    EPA Science Inventory

    The generic method described here involves typical capillary electrophoresis (CE) techniques, with the addition of cyclodextrin chiral selectors to the electrolyte for enantiomer separation and also, in the case of neutral analytes, the further addition of a micelle forming comp...

  14. Turbidimetric Estimation of Alcohol Concentration in Aqueous-Alcohol Mixtures

    ERIC Educational Resources Information Center

    Swinehart, William E.; Zimmerman, Bonnie L.; Powell, Kinsey; Moore, Stephen D.; Iordanov, Tzvetelin D.

    2014-01-01

    A concept of the turbidimetric method for determining the concentration of ethanol in water-ethanol mixtures is described. A closed sample cell containing the analyte was heated to achieve vapor saturation and subsequent condensation. As the condensation occurred, the decrease in percentage transmittance with time due to light scattering was…

  15. 40 CFR 51.856 - Public participation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Public participation. 51.856 Section 51... Federal Actions to State or Federal Implementation Plans § 51.856 Public participation. Link to an... § 51.858 with supporting materials which describe the analytical methods and conclusions relied upon in...

  16. Teaching Critical Analytical Methods in the Digital Typography Classroom.

    ERIC Educational Resources Information Center

    Gibson, Michael

    1997-01-01

    Describes a studio project designed to help students (1) utilize the digital environment to organize typography and images that represent the socio-political context their solutions were required to identify; and (2) explore the empirical variables that help readers to access and contemplate the content presented by their text. (PA)

  17. A Guide to Job Analysis for the Preparation of Job Training Programmes.

    ERIC Educational Resources Information Center

    Ceramics, Glass, and Mineral Products Industry Training Board, Harrow (England).

    The paper deals with job analysis for the preparation of job training programs. The analytical approach involves five steps: enlisting support, examining the job, describing the job, analyzing training requirements, and planning the programs. Appendixes include methods of producing training schemes--the simple job breakdown, straightforward…

  18. Classical Civilization (Greece-Hellenistic-Rome). Teacher's Manual. 1968 Edition.

    ERIC Educational Resources Information Center

    Leppert, Ella C.; Smith, Rozella B.

    This secondary teachers guide builds upon a previous sequential course described in SO 003 173, and consists of three sections on the classical civilizations--Greek, Hellenistic, and Rome. Major emphasis is upon students gaining an understanding of cultural development and transmission. Using an analytic method, students learn to examine primary…

  19. Deepening Instructional Reform through System Monitoring

    ERIC Educational Resources Information Center

    Supovitz, Jonathan

    2008-01-01

    This article describes the system of monitoring district instructional-reform efforts and the influences of the system on teachers and school and district leaders in Duval County, Florida. First, the author offers a brief description of the snapshot system. Second, the study's design, data sources, and analytic methods are presented. Third, the…

  20. Applicability of bioanalysis of multiple analytes in drug discovery and development: review of select case studies including assay development considerations.

    PubMed

    Srinivas, Nuggehally R

    2006-05-01

    The development of sound bioanalytical method(s) is of paramount importance during the process of drug discovery and development culminating in a marketing approval. Although the bioanalytical procedure(s) originally developed during the discovery stage may not necessarily be fit to support the drug development scenario, they may be suitably modified and validated, as deemed necessary. Several reviews have appeared over the years describing analytical approaches including various techniques, detection systems, automation tools that are available for an effective separation, enhanced selectivity and sensitivity for quantitation of many analytes. The intention of this review is to cover various key areas where analytical method development becomes necessary during different stages of drug discovery research and development process. The key areas covered in this article with relevant case studies include: (a) simultaneous assay for parent compound and metabolites that are purported to display pharmacological activity; (b) bioanalytical procedures for determination of multiple drugs in combating a disease; (c) analytical measurement of chirality aspects in the pharmacokinetics, metabolism and biotransformation investigations; (d) drug monitoring for therapeutic benefits and/or occupational hazard; (e) analysis of drugs from complex and/or less frequently used matrices; (f) analytical determination during in vitro experiments (metabolism and permeability related) and in situ intestinal perfusion experiments; (g) determination of a major metabolite as a surrogate for the parent molecule; (h) analytical approaches for universal determination of CYP450 probe substrates and metabolites; (i) analytical applicability to prodrug evaluations-simultaneous determination of prodrug, parent and metabolites; (j) quantitative determination of parent compound and/or phase II metabolite(s) via direct or indirect approaches; (k) applicability in analysis of multiple compounds in select disease areas and/or in clinically important drug-drug interaction studies. A tabular representation of select examples of analysis is provided covering areas of separation conditions, validation aspects and applicable conclusion. A limited discussion is provided on relevant aspects of the need for developing bioanalytical procedures for speedy drug discovery and development. Additionally, some key elements such as internal standard selection, likely issues of mass detection, matrix effect, chiral aspects etc. are provided for consideration during method development.

  1. Analytical method for the identification and assay of 12 phthalates in cosmetic products: application of the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques".

    PubMed

    Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine

    2012-08-31

    Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. On the nature of the fragment environment created by the range destruction or random failure of solid rocket motor casings

    NASA Technical Reports Server (NTRS)

    Eck, M.; Mukunda, M.

    1988-01-01

    Given here are predictions of fragment velocities and azimuths resulting from the Space Transportation System Solid Rocket Motor range destruct, or random failure occurring at any time during the 120 seconds of Solid Rocket Motor burn. Results obtained using the analytical methods described showed good agreement between predictions and observations for two specific events. It was shown that these methods have good potential for use in predicting the fragmentation process of a number of generically similar casing systems. It was concluded that coupled Eulerian-Lagrangian calculational methods of the type described here provide a powerful tool for predicting Solid Rocket Motor response.

  3. Thermodynamics of Newman-Unti-Tamburino charged spaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mann, Robert; Department of Physics, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1; Stelea, Cristian

    We discuss and compare at length the results of two methods used recently to describe the thermodynamics of Taub-Newman-Unti-Tamburino (NUT) solutions in a de Sitter background. In the first approach (C approach), one deals with an analytically continued version of the metric while in the second approach (R approach), the discussion is carried out using the unmodified metric with Lorentzian signature. No analytic continuation is performed on the coordinates and/or the parameters that appear in the metric. We find that the results of both these approaches are completely equivalent modulo analytic continuation and we provide the exact prescription that relatesmore » the results in both methods. The extension of these results to the AdS/flat cases aims to give a physical interpretation of the thermodynamics of NUT-charged spacetimes in the Lorentzian sector. We also briefly discuss the higher-dimensional spaces and note that, analogous with the absence of hyperbolic NUTs in AdS backgrounds, there are no spherical Taub-NUT-dS solutions.« less

  4. A mass spectrometry primer for mass spectrometry imaging

    PubMed Central

    Rubakhin, Stanislav S.; Sweedler, Jonathan V.

    2011-01-01

    Mass spectrometry imaging (MSI), a rapidly growing subfield of chemical imaging, employs mass spectrometry (MS) technologies to create single- and multi-dimensional localization maps for a variety of atoms and molecules. Complimentary to other imaging approaches, MSI provides high chemical specificity and broad analyte coverage. This powerful analytical toolset is capable of measuring the distribution of many classes of inorganics, metabolites, proteins and pharmaceuticals in chemically and structurally complex biological specimens in vivo, in vitro, and in situ. The MSI approaches highlighted in this Methods in Molecular Biology volume provide flexibility of detection, characterization, and identification of multiple known and unknown analytes. The goal of this chapter is to introduce investigators who may be unfamiliar with MS to the basic principles of the mass spectrometric approaches as used in MSI. In addition to guidelines for choosing the most suitable MSI method for specific investigations, cross-references are provided to the chapters in this volume that describe the appropriate experimental protocols. PMID:20680583

  5. Optimization of a Precolumn OPA Derivatization HPLC Assay for Monitoring of l-Asparagine Depletion in Serum during l-Asparaginase Therapy.

    PubMed

    Zhang, Mei; Zhang, Yong; Ren, Siqi; Zhang, Zunjian; Wang, Yongren; Song, Rui

    2018-06-06

    A method for monitoring l-asparagine (ASN) depletion in patients' serum using reversed-phase high-performance liquid chromatography with precolumn o-phthalaldehyde and ethanethiol (ET) derivatization is described. In order to improve the signal and stability of analytes, several important factors including precipitant reagent, derivatization conditions and detection wavelengths were optimized. The recovery of the analytes in biological matrix was the highest when 4% sulfosalicylic acid (1:1, v/v) was used as a precipitant reagent. Optimal fluorescence detection parameters were determined as λex = 340 nm and λem = 444 nm for maximal signal. The signal of analytes was the highest when the reagent ET and borate buffer of pH 9.9 were used in the derivatization solution. And the corresponding derivative products were stable up to 19 h. The validated method had been successfully applied to monitor ASN depletion and l-aspartic acid, l-glutamine, l-glutamic acid levels in pediatric patients during l-asparaginase therapy.

  6. Characterization of gamma-irradiated polyethylene terephthalate by liquid-chromatography mass-spectrometry (LC MS) with atmospheric-pressure chemical ionization (APCI)

    NASA Astrophysics Data System (ADS)

    Buchalla, Rainer; Begley, Timothy H.

    2006-01-01

    Low-molecular-weight (low-MW) constituents of polyethylene terephthalate (PET), irradiated with 60Co gamma rays at 25 and 50 kGy, were analyzed by HPLC-MS with atmospheric-pressure chemical ionization (APCI). Consistent with earlier results, the concentrations of the major compounds that are present in the non-irradiated PET do not change perceptibly. However, we find a small but significant increase in terephthalic acid ethylester, from less than 1 mg/kg in the non-irradiated control to ca. 2 mg/kg after 50 kGy, which has not been described before. The finding is important because it gives an impression of the sensitivity of the analytical method. Additionally, it shows that even very radiation-resistant polymers can form measurable amounts of low-MW radiolysis products. The potential and limitations of LC-MS for the analysis of radiolysis products and unidentified migrants are briefly discussed in the context of the question: How can we validate our analytical methods for unknown analytes?

  7. Reverse phase protein microarrays: fluorometric and colorimetric detection.

    PubMed

    Gallagher, Rosa I; Silvestri, Alessandra; Petricoin, Emanuel F; Liotta, Lance A; Espina, Virginia

    2011-01-01

    The Reverse Phase Protein Microarray (RPMA) is an array platform used to quantitate proteins and their posttranslationally modified forms. RPMAs are applicable for profiling key cellular signaling pathways and protein networks, allowing direct comparison of the activation state of proteins from multiple samples within the same array. The RPMA format consists of proteins immobilized directly on a nitrocellulose substratum. The analyte is subsequently probed with a primary antibody and a series of reagents for signal amplification and detection. Due to the diversity, low concentration, and large dynamic range of protein analytes, RPMAs require stringent signal amplification methods, high quality image acquisition, and software capable of precisely analyzing spot intensities on an array. Microarray detection strategies can be either fluorescent or colorimetric. The choice of a detection system depends on (a) the expected analyte concentration, (b) type of microarray imaging system, and (c) type of sample. The focus of this chapter is to describe RPMA detection and imaging using fluorescent and colorimetric (diaminobenzidine (DAB)) methods.

  8. A study of prediction methods for the high angle-of-attack aerodynamics of straight wings and fighter aircraft

    NASA Technical Reports Server (NTRS)

    Mcmillan, O. J.; Mendenhall, M. R.; Perkins, S. C., Jr.

    1984-01-01

    Work is described dealing with two areas which are dominated by the nonlinear effects of vortex flows. The first area concerns the stall/spin characteristics of a general aviation wing with a modified leading edge. The second area concerns the high-angle-of-attack characteristics of high performance military aircraft. For each area, the governing phenomena are described as identified with the aid of existing experimental data. Existing analytical methods are reviewed, and the most promising method for each area used to perform some preliminary calculations. Based on these results, the strengths and weaknesses of the methods are defined, and research programs recommended to improve the methods as a result of better understanding of the flow mechanisms involved.

  9. Estimation of the biserial correlation and its sampling variance for use in meta-analysis.

    PubMed

    Jacobs, Perke; Viechtbauer, Wolfgang

    2017-06-01

    Meta-analyses are often used to synthesize the findings of studies examining the correlational relationship between two continuous variables. When only dichotomous measurements are available for one of the two variables, the biserial correlation coefficient can be used to estimate the product-moment correlation between the two underlying continuous variables. Unlike the point-biserial correlation coefficient, biserial correlation coefficients can therefore be integrated with product-moment correlation coefficients in the same meta-analysis. The present article describes the estimation of the biserial correlation coefficient for meta-analytic purposes and reports simulation results comparing different methods for estimating the coefficient's sampling variance. The findings indicate that commonly employed methods yield inconsistent estimates of the sampling variance across a broad range of research situations. In contrast, consistent estimates can be obtained using two methods that appear to be unknown in the meta-analytic literature. A variance-stabilizing transformation for the biserial correlation coefficient is described that allows for the construction of confidence intervals for individual coefficients with close to nominal coverage probabilities in most of the examined conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Online Learner Engagement: Opportunities and Challenges with Using Data Analytics

    ERIC Educational Resources Information Center

    Bodily, Robert; Graham, Charles R.; Bush, Michael D.

    2017-01-01

    This article describes the crossroads between learning analytics and learner engagement. The authors do this by describing specific challenges of using analytics to support student engagement from three distinct perspectives: pedagogical considerations, technological issues, and interface design concerns. While engaging online learners presents a…

  11. Quantifying construction and demolition waste: An analytical review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Zezhou; Yu, Ann T.W., E-mail: bsannyu@polyu.edu.hk; Shen, Liyin

    2014-09-15

    Highlights: • Prevailing C and D waste quantification methodologies are identified and compared. • One specific methodology cannot fulfill all waste quantification scenarios. • A relevance tree for appropriate quantification methodology selection is proposed. • More attentions should be paid to civil and infrastructural works. • Classified information is suggested for making an effective waste management plan. - Abstract: Quantifying construction and demolition (C and D) waste generation is regarded as a prerequisite for the implementation of successful waste management. In literature, various methods have been employed to quantify the C and D waste generation at both regional and projectmore » levels. However, an integrated review that systemically describes and analyses all the existing methods has yet to be conducted. To bridge this research gap, an analytical review is conducted. Fifty-seven papers are retrieved based on a set of rigorous procedures. The characteristics of the selected papers are classified according to the following criteria - waste generation activity, estimation level and quantification methodology. Six categories of existing C and D waste quantification methodologies are identified, including site visit method, waste generation rate method, lifetime analysis method, classification system accumulation method, variables modelling method and other particular methods. A critical comparison of the identified methods is given according to their characteristics and implementation constraints. Moreover, a decision tree is proposed for aiding the selection of the most appropriate quantification method in different scenarios. Based on the analytical review, limitations of previous studies and recommendations of potential future research directions are further suggested.« less

  12. Double-multiple streamtube model for studying vertical-axis wind turbines

    NASA Astrophysics Data System (ADS)

    Paraschivoiu, Ion

    1988-08-01

    This work describes the present state-of-the-art in double-multiple streamtube method for modeling the Darrieus-type vertical-axis wind turbine (VAWT). Comparisons of the analytical results with the other predictions and available experimental data show a good agreement. This method, which incorporates dynamic-stall and secondary effects, can be used for generating a suitable aerodynamic-load model for structural design analysis of the Darrieus rotor.

  13. Application of kernel principal component analysis and computational machine learning to exploration of metabolites strongly associated with diet.

    PubMed

    Shiokawa, Yuka; Date, Yasuhiro; Kikuchi, Jun

    2018-02-21

    Computer-based technological innovation provides advancements in sophisticated and diverse analytical instruments, enabling massive amounts of data collection with relative ease. This is accompanied by a fast-growing demand for technological progress in data mining methods for analysis of big data derived from chemical and biological systems. From this perspective, use of a general "linear" multivariate analysis alone limits interpretations due to "non-linear" variations in metabolic data from living organisms. Here we describe a kernel principal component analysis (KPCA)-incorporated analytical approach for extracting useful information from metabolic profiling data. To overcome the limitation of important variable (metabolite) determinations, we incorporated a random forest conditional variable importance measure into our KPCA-based analytical approach to demonstrate the relative importance of metabolites. Using a market basket analysis, hippurate, the most important variable detected in the importance measure, was associated with high levels of some vitamins and minerals present in foods eaten the previous day, suggesting a relationship between increased hippurate and intake of a wide variety of vegetables and fruits. Therefore, the KPCA-incorporated analytical approach described herein enabled us to capture input-output responses, and should be useful not only for metabolic profiling but also for profiling in other areas of biological and environmental systems.

  14. An overview of selected NASP aeroelastic studies at the NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Spain, Charles V.; Soistmann, David L.; Parker, Ellen C.; Gibbons, Michael D.; Gilbert, Michael G.

    1990-01-01

    Following an initial discussion of the NASP flight environment, the results of recent aeroelastic testing of NASP-type highly swept delta-wing models in Langley's Transonic Dynamics Tunnel (TDT) are summarized. Subsonic and transonic flutter characteristics of a variety of these models are described, and several analytical codes used to predict flutter of these models are evaluated. These codes generally provide good, but conservative predictions of subsonic and transonic flutter. Also, test results are presented on a nonlinear transonic phenomena known as aileron buzz which occurred in the wind tunnel on highly swept delta wings with full-span ailerons. An analytical procedure which assesses the effects of hypersonic heating on aeroelastic instabilities (aerothermoelasticity) is also described. This procedure accurately predicted flutter of a heated aluminum wing on which experimental data exists. Results are presented on the application of this method to calculate the flutter characteristics of a fine-element model of a generic NASP configuration. Finally, it is demonstrated analytically that active controls can be employed to improve the aeroelastic stability and ride quality of a generic NASP vehicle flying at hypersonic speeds.

  15. Engineering of a miniaturized, robotic clinical laboratory

    PubMed Central

    Nourse, Marilyn B.; Engel, Kate; Anekal, Samartha G.; Bailey, Jocelyn A.; Bhatta, Pradeep; Bhave, Devayani P.; Chandrasekaran, Shekar; Chen, Yutao; Chow, Steven; Das, Ushati; Galil, Erez; Gong, Xinwei; Gessert, Steven F.; Ha, Kevin D.; Hu, Ran; Hyland, Laura; Jammalamadaka, Arvind; Jayasurya, Karthik; Kemp, Timothy M.; Kim, Andrew N.; Lee, Lucie S.; Liu, Yang Lily; Nguyen, Alphonso; O'Leary, Jared; Pangarkar, Chinmay H.; Patel, Paul J.; Quon, Ken; Ramachandran, Pradeep L.; Rappaport, Amy R.; Roy, Joy; Sapida, Jerald F.; Sergeev, Nikolay V.; Shee, Chandan; Shenoy, Renuka; Sivaraman, Sharada; Sosa‐Padilla, Bernardo; Tran, Lorraine; Trent, Amanda; Waggoner, Thomas C.; Wodziak, Dariusz; Yuan, Amy; Zhao, Peter; Holmes, Elizabeth A.

    2018-01-01

    Abstract The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay‐configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay‐specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti‐herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration‐cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations. PMID:29376134

  16. Engineering of a miniaturized, robotic clinical laboratory.

    PubMed

    Nourse, Marilyn B; Engel, Kate; Anekal, Samartha G; Bailey, Jocelyn A; Bhatta, Pradeep; Bhave, Devayani P; Chandrasekaran, Shekar; Chen, Yutao; Chow, Steven; Das, Ushati; Galil, Erez; Gong, Xinwei; Gessert, Steven F; Ha, Kevin D; Hu, Ran; Hyland, Laura; Jammalamadaka, Arvind; Jayasurya, Karthik; Kemp, Timothy M; Kim, Andrew N; Lee, Lucie S; Liu, Yang Lily; Nguyen, Alphonso; O'Leary, Jared; Pangarkar, Chinmay H; Patel, Paul J; Quon, Ken; Ramachandran, Pradeep L; Rappaport, Amy R; Roy, Joy; Sapida, Jerald F; Sergeev, Nikolay V; Shee, Chandan; Shenoy, Renuka; Sivaraman, Sharada; Sosa-Padilla, Bernardo; Tran, Lorraine; Trent, Amanda; Waggoner, Thomas C; Wodziak, Dariusz; Yuan, Amy; Zhao, Peter; Young, Daniel L; Robertson, Channing R; Holmes, Elizabeth A

    2018-01-01

    The ability to perform laboratory testing near the patient and with smaller blood volumes would benefit patients and physicians alike. We describe our design of a miniaturized clinical laboratory system with three components: a hardware platform (ie, the miniLab) that performs preanalytical and analytical processing steps using miniaturized sample manipulation and detection modules, an assay-configurable cartridge that provides consumable materials and assay reagents, and a server that communicates bidirectionally with the miniLab to manage assay-specific protocols and analyze, store, and report results (i.e., the virtual analyzer). The miniLab can detect analytes in blood using multiple methods, including molecular diagnostics, immunoassays, clinical chemistry, and hematology. Analytical performance results show that our qualitative Zika virus assay has a limit of detection of 55 genomic copies/ml. For our anti-herpes simplex virus type 2 immunoglobulin G, lipid panel, and lymphocyte subset panel assays, the miniLab has low imprecision, and method comparison results agree well with those from the United States Food and Drug Administration-cleared devices. With its small footprint and versatility, the miniLab has the potential to provide testing of a range of analytes in decentralized locations.

  17. Probability of identification: a statistical model for the validation of qualitative botanical identification methods.

    PubMed

    LaBudde, Robert A; Harnly, James M

    2012-01-01

    A qualitative botanical identification method (BIM) is an analytical procedure that returns a binary result (1 = Identified, 0 = Not Identified). A BIM may be used by a buyer, manufacturer, or regulator to determine whether a botanical material being tested is the same as the target (desired) material, or whether it contains excessive nontarget (undesirable) material. The report describes the development and validation of studies for a BIM based on the proportion of replicates identified, or probability of identification (POI), as the basic observed statistic. The statistical procedures proposed for data analysis follow closely those of the probability of detection, and harmonize the statistical concepts and parameters between quantitative and qualitative method validation. Use of POI statistics also harmonizes statistical concepts for botanical, microbiological, toxin, and other analyte identification methods that produce binary results. The POI statistical model provides a tool for graphical representation of response curves for qualitative methods, reporting of descriptive statistics, and application of performance requirements. Single collaborator and multicollaborative study examples are given.

  18. Orthogonal analytical methods for botanical standardization: Determination of green tea catechins by qNMR and LC-MS/MS

    PubMed Central

    Napolitano, José G.; Gödecke, Tanja; Lankin, David C.; Jaki, Birgit U.; McAlpine, James B.; Chen, Shao-Nong; Pauli, Guido F.

    2013-01-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative 1H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted 1H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. PMID:23870106

  19. Variational path integral molecular dynamics and hybrid Monte Carlo algorithms using a fourth order propagator with applications to molecular systems

    NASA Astrophysics Data System (ADS)

    Kamibayashi, Yuki; Miura, Shinichi

    2016-08-01

    In the present study, variational path integral molecular dynamics and associated hybrid Monte Carlo (HMC) methods have been developed on the basis of a fourth order approximation of a density operator. To reveal various parameter dependence of physical quantities, we analytically solve one dimensional harmonic oscillators by the variational path integral; as a byproduct, we obtain the analytical expression of the discretized density matrix using the fourth order approximation for the oscillators. Then, we apply our methods to realistic systems like a water molecule and a para-hydrogen cluster. In the HMC, we adopt two level description to avoid the time consuming Hessian evaluation. For the systems examined in this paper, the HMC method is found to be about three times more efficient than the molecular dynamics method if appropriate HMC parameters are adopted; the advantage of the HMC method is suggested to be more evident for systems described by many body interaction.

  20. Simultaneous determination of dextromethorphan, dextrorphan and doxylamine in human plasma by HPLC coupled to electrospray ionization tandem mass spectrometry: application to a pharmacokinetic study.

    PubMed

    Donato, J L; Koizumi, F; Pereira, A S; Mendes, G D; De Nucci, G

    2012-06-15

    In the present study, a fast, sensitive and robust method to quantify dextromethorphan, dextrorphan and doxylamine in human plasma using deuterated internal standards (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction (LLE) using diethyl-ether/hexane (80/20, v/v). Extracted samples were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase (acetonitrile/water/formic acid (90/9/1, v/v/v) during 4.0min at a flow-rate of 1.5 mL min⁻¹ into a Phenomenex Gemini® C18, 5 μm analytical column (150 × 4.6 mm i.d.). The calibration curve was linear over the range from 0.2 to 200 ng mL⁻¹ for dextromethorphan and doxylamine and 0.05 to 10 ng mL⁻¹ for dextrorphan. The intra-batch precision and accuracy (%CV) of the method ranged from 2.5 to 9.5%, and 88.9 to 105.1%, respectively. Method inter-batch precision (%CV) and accuracy ranged from 6.7 to 10.3%, and 92.2 to 107.1%, respectively. The run-time was for 4 min. The analytical procedure herein described was used to assess the pharmacokinetics of dextromethorphan, dextrorphan and doxylamine in healthy volunteers after a single oral dose of a formulation containing 30 mg of dextromethorphan hydrobromide and 12.5mg of doxylamine succinate. The method has high sensitivity, specificity and allows high throughput analysis required for a pharmacokinetic study. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Engineering and programming manual: Two-dimensional kinetic reference computer program (TDK)

    NASA Technical Reports Server (NTRS)

    Nickerson, G. R.; Dang, L. D.; Coats, D. E.

    1985-01-01

    The Two Dimensional Kinetics (TDK) computer program is a primary tool in applying the JANNAF liquid rocket thrust chamber performance prediction methodology. The development of a methodology that includes all aspects of rocket engine performance from analytical calculation to test measurements, that is physically accurate and consistent, and that serves as an industry and government reference is presented. Recent interest in rocket engines that operate at high expansion ratio, such as most Orbit Transfer Vehicle (OTV) engine designs, has required an extension of the analytical methods used by the TDK computer program. Thus, the version of TDK that is described in this manual is in many respects different from the 1973 version of the program. This new material reflects the new capabilities of the TDK computer program, the most important of which are described.

  2. Flight Test Experiment Design for Characterizing Stability and Control of Hypersonic Vehicles

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.

    2008-01-01

    A maneuver design method that is particularly well-suited for determining the stability and control characteristics of hypersonic vehicles is described in detail. Analytical properties of the maneuver design are explained. The importance of these analytical properties for maximizing information content in flight data is discussed, along with practical implementation issues. Results from flight tests of the X-43A hypersonic research vehicle (also called Hyper-X) are used to demonstrate the excellent modeling results obtained using this maneuver design approach. A detailed design procedure for generating the maneuvers is given to allow application to other flight test programs.

  3. Solid Lubrication Fundamentals and Applications. Chapter 2

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1998-01-01

    This chapter describes powerful analytical techniques capable of sampling tribological surfaces and solid-film lubricants. Some of these techniques may also be used to determine the locus of failure in a bonded structure or coated substrate; such information is important when seeking improved adhesion between a solid-film lubricant and a substrate and when seeking improved performance and long life expectancy of solid lubricants. Many examples are given here and through-out the book on the nature and character of solid surfaces and their significance in lubrication, friction, and wear. The analytical techniques used include the late spectroscopic methods.

  4. Analytical and numerical solutions of the equation for the beam propagation in a photovoltaic-photorefractive media

    NASA Astrophysics Data System (ADS)

    Lin, Ji; Wang, Hou

    2013-07-01

    We use the classical Lie-group method to study the evolution equation describing a photovoltaic-photorefractive media with the effects of diffusion process and the external electric field. We reduce it to some similarity equations firstly, and then obtain some analytically exact solutions including the soliton solution, the exponential solution and the oscillatory solution. We also obtain the numeric solitons from these similarity equations. Moreover, We show theoretically that these solutions have two types of trajectories. One type is a straight line. The other is a parabolic curve, which indicates these solitons have self-deflection.

  5. Big data sharing and analysis to advance research in post-traumatic epilepsy.

    PubMed

    Duncan, Dominique; Vespa, Paul; Pitkanen, Asla; Braimah, Adebayo; Lapinlampi, Nina; Toga, Arthur W

    2018-06-01

    We describe the infrastructure and functionality for a centralized preclinical and clinical data repository and analytic platform to support importing heterogeneous multi-modal data, automatically and manually linking data across modalities and sites, and searching content. We have developed and applied innovative image and electrophysiology processing methods to identify candidate biomarkers from MRI, EEG, and multi-modal data. Based on heterogeneous biomarkers, we present novel analytic tools designed to study epileptogenesis in animal model and human with the goal of tracking the probability of developing epilepsy over time. Copyright © 2017. Published by Elsevier Inc.

  6. Replica Analysis for Portfolio Optimization with Single-Factor Model

    NASA Astrophysics Data System (ADS)

    Shinzato, Takashi

    2017-06-01

    In this paper, we use replica analysis to investigate the influence of correlation among the return rates of assets on the solution of the portfolio optimization problem. We consider the behavior of an optimal solution for the case where the return rate is described with a single-factor model and compare the findings obtained from our proposed methods with correlated return rates with those obtained with independent return rates. We then analytically assess the increase in the investment risk when correlation is included. Furthermore, we also compare our approach with analytical procedures for minimizing the investment risk from operations research.

  7. Measurement of Plastic Stress and Strain for Analytical Method Verification (MSFC Center Director's Discretionary Fund Project No. 93-08)

    NASA Technical Reports Server (NTRS)

    Price, J. M.; Steeve, B. E.; Swanson, G. R.

    1999-01-01

    The analytical prediction of stress, strain, and fatigue life at locations experiencing local plasticity is full of uncertainties. Much of this uncertainty arises from the material models and their use in the numerical techniques used to solve plasticity problems. Experimental measurements of actual plastic strains would allow the validity of these models and solutions to be tested. This memorandum describes how experimental plastic residual strain measurements were used to verify the results of a thermally induced plastic fatigue failure analysis of a space shuttle main engine fuel pump component.

  8. Remote measurements of water pollution with a lidar polarimeter

    NASA Technical Reports Server (NTRS)

    Sheives, T. C.; Rouse, J. W., Jr.; Mayo, W. T., Jr.

    1974-01-01

    This paper examines a dual polarization laser backscatter system as a method for remote measurements of certain water quality parameters. Analytical models for describing the backscatter from turbid water and oil on turbid water are presented and compared with experimental data. Laser backscatter field measurements from natural waterways are presented and compared with simultaneous ground observations of the water quality parameters: turbidity, suspended solids, and transmittance. The results of this study show that the analytical models appear valid and that the sensor investigated is applicable to remote measurements of these water quality parameters and oil spills on water.-

  9. Validation of the enthalpy method by means of analytical solution

    NASA Astrophysics Data System (ADS)

    Kleiner, Thomas; Rückamp, Martin; Bondzio, Johannes; Humbert, Angelika

    2014-05-01

    Numerical simulations moved in the recent year(s) from describing the cold-temperate transition surface (CTS) towards an enthalpy description, which allows avoiding incorporating a singular surface inside the model (Aschwanden et al., 2012). In Enthalpy methods the CTS is represented as a level set of the enthalpy state variable. This method has several numerical and practical advantages (e.g. representation of the full energy by one scalar field, no restriction to topology and shape of the CTS). The proposed method is rather new in glaciology and to our knowledge not verified and validated against analytical solutions. Unfortunately we are still lacking analytical solutions for sufficiently complex thermo-mechanically coupled polythermal ice flow. However, we present two experiments to test the implementation of the enthalpy equation and corresponding boundary conditions. The first experiment tests particularly the functionality of the boundary condition scheme and the corresponding basal melt rate calculation. Dependent on the different thermal situations that occur at the base, the numerical code may have to switch to another boundary type (from Neuman to Dirichlet or vice versa). The main idea of this set-up is to test the reversibility during transients. A former cold ice body that run through a warmer period with an associated built up of a liquid water layer at the base must be able to return to its initial steady state. Since we impose several assumptions on the experiment design analytical solutions can be formulated for different quantities during distinct stages of the simulation. The second experiment tests the positioning of the internal CTS in a parallel-sided polythermal slab. We compare our simulation results to the analytical solution proposed by Greve and Blatter (2009). Results from three different ice flow-models (COMIce, ISSM, TIMFD3) are presented.

  10. Analytic Methods for Evaluating Patterns of Multiple Congenital Anomalies in Birth Defect Registries.

    PubMed

    Agopian, A J; Evans, Jane A; Lupo, Philip J

    2018-01-15

    It is estimated that 20 to 30% of infants with birth defects have two or more birth defects. Among these infants with multiple congenital anomalies (MCA), co-occurring anomalies may represent either chance (i.e., unrelated etiologies) or pathogenically associated patterns of anomalies. While some MCA patterns have been recognized and described (e.g., known syndromes), others have not been identified or characterized. Elucidating these patterns may result in a better understanding of the etiologies of these MCAs. This article reviews the literature with regard to analytic methods that have been used to evaluate patterns of MCAs, in particular those using birth defect registry data. A popular method for MCA assessment involves a comparison of the observed to expected ratio for a given combination of MCAs, or one of several modified versions of this comparison. Other methods include use of numerical taxonomy or other clustering techniques, multiple regression analysis, and log-linear analysis. Advantages and disadvantages of these approaches, as well as specific applications, were outlined. Despite the availability of multiple analytic approaches, relatively few MCA combinations have been assessed. The availability of large birth defects registries and computing resources that allow for automated, big data strategies for prioritizing MCA patterns may provide for new avenues for better understanding co-occurrence of birth defects. Thus, the selection of an analytic approach may depend on several considerations. Birth Defects Research 110:5-11, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. Determination of glycols in air: development of sampling and analytical methodology and application to theatrical smokes.

    PubMed

    Pendergrass, S M

    1999-01-01

    Glycol-based fluids are used in the production of theatrical smokes in theaters, concerts, and other stage productions. The fluids are heated and dispersed in aerosol form to create the effect of a smoke, mist, or fog. There have been reports of adverse health effects such as respiratory irritation, chest tightness, shortness of breath, asthma, and skin rashes. Previous attempts to collect and quantify the aerosolized glycols used in fogging agents have been plagued by inconsistent results, both in the efficiency of collection and in the chromatographic analysis of the glycol components. The development of improved sampling and analytical methodology for aerosolized glycols was required to assess workplace exposures more effectively. An Occupational Safety and Health Administration versatile sampler tube was selected for the collection of ethylene glycol, propylene glycol, 1,3-butylene glycol, diethylene glycol, triethylene glycol, and tetraethylene glycol aerosols. Analytical methodology for the separation, identification, and quantitation of the six glycols using gas chromatography/flame ionization detection is described. Limits of detection of the glycol analytes ranged from 7 to 16 micrograms/sample. Desorption efficiencies for all glycol compounds were determined over the range of study and averaged greater than 90%. Storage stability results were acceptable after 28 days for all analytes except ethylene glycol, which was stable at ambient temperature for 14 days. Based on the results of this study, the new glycol method was published in the NIOSH Manual of Analytical Methods.

  12. Dynamic Rod Worth Measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chao, Y.A.; Chapman, D.M.; Hill, D.J.

    2000-12-15

    The dynamic rod worth measurement (DRWM) technique is a method of quickly validating the predicted bank worth of control rods and shutdown rods. The DRWM analytic method is based on three-dimensional, space-time kinetic simulations of the rapid rod movements. Its measurement data is processed with an advanced digital reactivity computer. DRWM has been used as the method of bank worth validation at numerous plant startups with excellent results. The process and methodology of DRWM are described, and the measurement results of using DRWM are presented.

  13. Quantitative Determination of Caffeine in Beverages Using a Combined SPME-GC/MS Method

    NASA Astrophysics Data System (ADS)

    Pawliszyn, Janusz; Yang, Min J.; Orton, Maureen L.

    1997-09-01

    Solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) has been applied to the analysis of various caffeinated beverages. Unlike the current methods, this technique is solvent free and requires no pH adjustments. The simplicity of the SPME-GC/MS method lends itself to a good undergraduate laboratory practice. This publication describes the analytical conditions and presents the data for determination of caffeine in coffee, tea, and coke. Quantitation by isotopic dilution is also illustrated.

  14. Heat Transfer Analysis of Thermal Protection Structures for Hypersonic Vehicles

    NASA Astrophysics Data System (ADS)

    Zhou, Chen; Wang, Zhijin; Hou, Tianjiao

    2017-11-01

    This research aims to develop an analytical approach to study the heat transfer problem of thermal protection systems (TPS) for hypersonic vehicles. Laplace transform and integral method are used to describe the temperature distribution through the TPS subject to aerodynamic heating during flight. Time-dependent incident heat flux is also taken into account. Two different cases with heat flux and radiation boundary conditions are studied and discussed. The results are compared with those obtained by finite element analyses and show a good agreement. Although temperature profiles of such problems can be readily accessed via numerical simulations, analytical solutions give a greater insight into the physical essence of the heat transfer problem. Furthermore, with the analytical approach, rapid thermal analyses and even thermal optimization can be achieved during the preliminary TPS design.

  15. Tire Changes, Fresh Air, and Yellow Flags: Challenges in Predictive Analytics for Professional Racing.

    PubMed

    Tulabandhula, Theja; Rudin, Cynthia

    2014-06-01

    Our goal is to design a prediction and decision system for real-time use during a professional car race. In designing a knowledge discovery process for racing, we faced several challenges that were overcome only when domain knowledge of racing was carefully infused within statistical modeling techniques. In this article, we describe how we leveraged expert knowledge of the domain to produce a real-time decision system for tire changes within a race. Our forecasts have the potential to impact how racing teams can optimize strategy by making tire-change decisions to benefit their rank position. Our work significantly expands previous research on sports analytics, as it is the only work on analytical methods for within-race prediction and decision making for professional car racing.

  16. Earth Science Data Analytics: Bridging Tools and Techniques with the Co-Analysis of Large, Heterogeneous Datasets

    NASA Technical Reports Server (NTRS)

    Kempler, Steve; Mathews, Tiffany

    2016-01-01

    The continuum of ever-evolving data management systems affords great opportunities to the enhancement of knowledge and facilitation of science research. To take advantage of these opportunities, it is essential to understand and develop methods that enable data relationships to be examined and the information to be manipulated. This presentation describes the efforts of the Earth Science Information Partners (ESIP) Federation Earth Science Data Analytics (ESDA) Cluster to understand, define, and facilitate the implementation of ESDA to advance science research. As a result of the void of Earth science data analytics publication material, the cluster has defined ESDA along with 10 goals to set the framework for a common understanding of tools and techniques that are available and still needed to support ESDA.

  17. Analytical solution for vacuum preloading considering the nonlinear distribution of horizontal permeability within the smear zone.

    PubMed

    Peng, Jie; He, Xiang; Ye, Hanming

    2015-01-01

    The vacuum preloading is an effective method which is widely used in ground treatment. In consolidation analysis, the soil around prefabricated vertical drain (PVD) is traditionally divided into smear zone and undisturbed zone, both with constant permeability. In reality, the permeability of soil changes continuously within the smear zone. In this study, the horizontal permeability coefficient of soil within the smear zone is described by an exponential function of radial distance. A solution for vacuum preloading consolidation considers the nonlinear distribution of horizontal permeability within the smear zone is presented and compared with previous analytical results as well as a numerical solution, the results show that the presented solution correlates well with the numerical solution, and is more precise than previous analytical solution.

  18. Least Square Regression Method for Estimating Gas Concentration in an Electronic Nose System

    PubMed Central

    Khalaf, Walaa; Pace, Calogero; Gaudioso, Manlio

    2009-01-01

    We describe an Electronic Nose (ENose) system which is able to identify the type of analyte and to estimate its concentration. The system consists of seven sensors, five of them being gas sensors (supplied with different heater voltage values), the remainder being a temperature and a humidity sensor, respectively. To identify a new analyte sample and then to estimate its concentration, we use both some machine learning techniques and the least square regression principle. In fact, we apply two different training models; the first one is based on the Support Vector Machine (SVM) approach and is aimed at teaching the system how to discriminate among different gases, while the second one uses the least squares regression approach to predict the concentration of each type of analyte. PMID:22573980

  19. Analytical solution for vacuum preloading considering the nonlinear distribution of horizontal permeability within the smear zone

    PubMed Central

    Peng, Jie; He, Xiang; Ye, Hanming

    2015-01-01

    The vacuum preloading is an effective method which is widely used in ground treatment. In consolidation analysis, the soil around prefabricated vertical drain (PVD) is traditionally divided into smear zone and undisturbed zone, both with constant permeability. In reality, the permeability of soil changes continuously within the smear zone. In this study, the horizontal permeability coefficient of soil within the smear zone is described by an exponential function of radial distance. A solution for vacuum preloading consolidation considers the nonlinear distribution of horizontal permeability within the smear zone is presented and compared with previous analytical results as well as a numerical solution, the results show that the presented solution correlates well with the numerical solution, and is more precise than previous analytical solution. PMID:26447973

  20. Geovisual analytics to enhance spatial scan statistic interpretation: an analysis of U.S. cervical cancer mortality

    PubMed Central

    Chen, Jin; Roth, Robert E; Naito, Adam T; Lengerich, Eugene J; MacEachren, Alan M

    2008-01-01

    Background Kulldorff's spatial scan statistic and its software implementation – SaTScan – are widely used for detecting and evaluating geographic clusters. However, two issues make using the method and interpreting its results non-trivial: (1) the method lacks cartographic support for understanding the clusters in geographic context and (2) results from the method are sensitive to parameter choices related to cluster scaling (abbreviated as scaling parameters), but the system provides no direct support for making these choices. We employ both established and novel geovisual analytics methods to address these issues and to enhance the interpretation of SaTScan results. We demonstrate our geovisual analytics approach in a case study analysis of cervical cancer mortality in the U.S. Results We address the first issue by providing an interactive visual interface to support the interpretation of SaTScan results. Our research to address the second issue prompted a broader discussion about the sensitivity of SaTScan results to parameter choices. Sensitivity has two components: (1) the method can identify clusters that, while being statistically significant, have heterogeneous contents comprised of both high-risk and low-risk locations and (2) the method can identify clusters that are unstable in location and size as the spatial scan scaling parameter is varied. To investigate cluster result stability, we conducted multiple SaTScan runs with systematically selected parameters. The results, when scanning a large spatial dataset (e.g., U.S. data aggregated by county), demonstrate that no single spatial scan scaling value is known to be optimal to identify clusters that exist at different scales; instead, multiple scans that vary the parameters are necessary. We introduce a novel method of measuring and visualizing reliability that facilitates identification of homogeneous clusters that are stable across analysis scales. Finally, we propose a logical approach to proceed through the analysis of SaTScan results. Conclusion The geovisual analytics approach described in this manuscript facilitates the interpretation of spatial cluster detection methods by providing cartographic representation of SaTScan results and by providing visualization methods and tools that support selection of SaTScan parameters. Our methods distinguish between heterogeneous and homogeneous clusters and assess the stability of clusters across analytic scales. Method We analyzed the cervical cancer mortality data for the United States aggregated by county between 2000 and 2004. We ran SaTScan on the dataset fifty times with different parameter choices. Our geovisual analytics approach couples SaTScan with our visual analytic platform, allowing users to interactively explore and compare SaTScan results produced by different parameter choices. The Standardized Mortality Ratio and reliability scores are visualized for all the counties to identify stable, homogeneous clusters. We evaluated our analysis result by comparing it to that produced by other independent techniques including the Empirical Bayes Smoothing and Kafadar spatial smoother methods. The geovisual analytics approach introduced here is developed and implemented in our Java-based Visual Inquiry Toolkit. PMID:18992163

  1. Development of an Advanced HPLC–MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma

    PubMed Central

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-01-01

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids. PMID:27754400

  2. Capillary Electrophoresis Sensitivity Enhancement Based on Adaptive Moving Average Method.

    PubMed

    Drevinskas, Tomas; Telksnys, Laimutis; Maruška, Audrius; Gorbatsova, Jelena; Kaljurand, Mihkel

    2018-06-05

    In the present work, we demonstrate a novel approach to improve the sensitivity of the "out of lab" portable capillary electrophoretic measurements. Nowadays, many signal enhancement methods are (i) underused (nonoptimal), (ii) overused (distorts the data), or (iii) inapplicable in field-portable instrumentation because of a lack of computational power. The described innovative migration velocity-adaptive moving average method uses an optimal averaging window size and can be easily implemented with a microcontroller. The contactless conductivity detection was used as a model for the development of a signal processing method and the demonstration of its impact on the sensitivity. The frequency characteristics of the recorded electropherograms and peaks were clarified. Higher electrophoretic mobility analytes exhibit higher-frequency peaks, whereas lower electrophoretic mobility analytes exhibit lower-frequency peaks. On the basis of the obtained data, a migration velocity-adaptive moving average algorithm was created, adapted, and programmed into capillary electrophoresis data-processing software. Employing the developed algorithm, each data point is processed depending on a certain migration time of the analyte. Because of the implemented migration velocity-adaptive moving average method, the signal-to-noise ratio improved up to 11 times for sampling frequency of 4.6 Hz and up to 22 times for sampling frequency of 25 Hz. This paper could potentially be used as a methodological guideline for the development of new smoothing algorithms that require adaptive conditions in capillary electrophoresis and other separation methods.

  3. A LITERATURE REVIEW OF WIPE SAMPLING METHODS ...

    EPA Pesticide Factsheets

    Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerousmethods of wipe sampling exist, and each method has its own specification for the type of wipe, wetting solvent, and determinative step to be used, depending upon the contaminant of concern. The objective of this report is to concisely summarize the findings of a literature review that was conducted to identify the state-of-the-art wipe sampling techniques for a target list of compounds. This report describes the methods used to perform the literature review; a brief review of wipe sampling techniques in general; an analysis of physical and chemical properties of each target analyte; an analysis of wipe sampling techniques for the target analyte list; and asummary of the wipe sampling techniques for the target analyte list, including existing data gaps. In general, no overwhelming consensus can be drawn from the current literature on how to collect a wipe sample for the chemical warfare agents, organophosphate pesticides, and other toxic industrial chemicals of interest to this study. Different methods, media, and wetting solvents have been recommended and used by various groups and different studies. For many of the compounds of interest, no specific wipe sampling methodology has been established for their collection. Before a wipe sampling method (or methods) can be established for the co

  4. Development of an Advanced HPLC-MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma.

    PubMed

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-10-14

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC-MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC-DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids.

  5. Visualization of the Mode Shapes of Pressure Oscillation in a Cylindrical Cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Xin; Qi, Yunliang; Wang, Zhi

    Our work describes a novel experimental method to visualize the mode shapes of pressure oscillation in a cylindrical cavity. Acoustic resonance in a cavity is a grand old problem that has been under investigation (using both analytical and numerical methods) for more than a century. In this article, a novel method based on high speed imaging of combustion chemiluminescence was presented to visualize the mode shapes of pressure oscillation in a cylindrical cavity. By generating high-temperature combustion gases and strong pressure waves simultaneously in a cylindrical cavity, the pressure oscillation can be inferred due to the chemiluminescence emissions of themore » combustion products. We can then visualized the mode shapes by reconstructing the images based on the amplitudes of the luminosity spectrum at the corresponding resonant frequencies. Up to 11 resonant mode shapes were clearly visualized, each matching very well with the analytical solutions.« less

  6. Determination of cocaine, benzoylecgonine and cocaethylene in human hair by solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    de Toledo, Fernanda Crossi Pereira; Yonamine, Mauricio; de Moraes Moreau, Regina Lucia; Silva, Ovandir Alves

    2003-12-25

    The present work describes a highly precise and sensitive method developed to detect cocaine (COC), benzoylecgonine (BE, its main metabolite) and cocaethylene (CE, transesterification product of the coingestion of COC with ethanol) in human head hair samples. The method was based on an alkylchloroformate derivatization of benzoylecgonine and the extraction of the analytes by solid-phase microextraction (SPME). Gas chromatography-mass spectrometry (GC-MS) was used to identify and quantify the analytes in selected ion monitoring mode (SIM). The limits of quantification and detection (LOQ and LOD) were: 0.1 ng/mg for COC and CE, and 0.5 ng/mg for BE. Good inter- and intra-assay precision was observed. The dynamic range of the assay was 0.1-50 ng/mg. The method is not time consuming and was shown to be easy to perform.

  7. Free and Forced Vibrations of Thick-Walled Anisotropic Cylindrical Shells

    NASA Astrophysics Data System (ADS)

    Marchuk, A. V.; Gnedash, S. V.; Levkovskii, S. A.

    2017-03-01

    Two approaches to studying the free and forced axisymmetric vibrations of cylindrical shell are proposed. They are based on the three-dimensional theory of elasticity and division of the original cylindrical shell with concentric cross-sectional circles into several coaxial cylindrical shells. One approach uses linear polynomials to approximate functions defined in plan and across the thickness. The other approach also uses linear polynomials to approximate functions defined in plan, but their variation with thickness is described by the analytical solution of a system of differential equations. Both approaches have approximation and arithmetic errors. When determining the natural frequencies by the semi-analytical finite-element method in combination with the divide and conqure method, it is convenient to find the initial frequencies by the finite-element method. The behavior of the shell during free and forced vibrations is analyzed in the case where the loading area is half the shell thickness

  8. Consistent approach to describing aircraft HIRF protection

    NASA Technical Reports Server (NTRS)

    Rimbey, P. R.; Walen, D. B.

    1995-01-01

    The high intensity radiated fields (HIRF) certification process as currently implemented is comprised of an inconsistent combination of factors that tend to emphasize worst case scenarios in assessing commercial airplane certification requirements. By examining these factors which include the process definition, the external HIRF environment, the aircraft coupling and corresponding internal fields, and methods of measuring equipment susceptibilities, activities leading to an approach to appraising airplane vulnerability to HIRF are proposed. This approach utilizes technically based criteria to evaluate the nature of the threat, including the probability of encountering the external HIRF environment. No single test or analytic method comprehensively addresses the full HIRF threat frequency spectrum. Additional tools such as statistical methods must be adopted to arrive at more realistic requirements to reflect commercial aircraft vulnerability to the HIRF threat. Test and analytic data are provided to support the conclusions of this report. This work was performed under NASA contract NAS1-19360, Task 52.

  9. Trace and surface analysis of ceramic layers of solid oxide fuel cells by mass spectrometry.

    PubMed

    Becker, J S; Breuer, U; Westheide, J; Saprykin, A I; Holzbrecher, H; Nickel, H; Dietze, H J

    1996-06-01

    For the trace analysis of impurities in thick ceramic layers of a solid oxide fuel cell (SOFC) sensitive solid-state mass spectrometric methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and radiofrequency glow discharge mass spectrometry (rf-GDMS) have been developed and used. In order to quantify the analytical results of LA-ICP-MS, the relative sensitivity coefficients of elements in a La(0.6)Sr(0.35)MnO(3) matrix have been determined using synthetic standards. Secondary ion mass spectrometry (SIMS) - as a surface analytical method - has been used to characterize the element distribution and diffusion profiles of matrix elements on the interface of a perovskite/Y-stabilized ZrO(2) layer. The application of different mass spectrometric methods for process control in the preparation of ceramic layers for the SOFC is described.

  10. Sample normalization methods in quantitative metabolomics.

    PubMed

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Analytical and molecular dynamics studies on the impact loading of single-layered graphene sheet by fullerene

    NASA Astrophysics Data System (ADS)

    Hosseini-Hashemi, Shahrokh; Sepahi-Boroujeni, Amin; Sepahi-Boroujeni, Saeid

    2018-04-01

    Normal impact performance of a system including a fullerene molecule and a single-layered graphene sheet is studied in the present paper. Firstly, through a mathematical approach, a new contact law is derived to describe the overall non-bonding interaction forces of the "hollow indenter-target" system. Preliminary verifications show that the derived contact law gives a reliable picture of force field of the system which is in good agreements with the results of molecular dynamics (MD) simulations. Afterwards, equation of the transversal motion of graphene sheet is utilized on the basis of both the nonlocal theory of elasticity and the assumptions of classical plate theory. Then, to derive dynamic behavior of the system, a set including the proposed contact law and the equations of motion of both graphene sheet and fullerene molecule is solved numerically. In order to evaluate outcomes of this method, the problem is modeled by MD simulation. Despite intrinsic differences between analytical and MD methods as well as various errors arise due to transient nature of the problem, acceptable agreements are established between analytical and MD outcomes. As a result, the proposed analytical method can be reliably used to address similar impact problems. Furthermore, it is found that a single-layered graphene sheet is capable of trapping fullerenes approaching with low velocities. Otherwise, in case of rebound, the sheet effectively absorbs predominant portion of fullerene energy.

  12. Infancy to Early Childhood: Genetic and Environmental Influences on Developmental Change.

    ERIC Educational Resources Information Center

    Emde, Robert N., Ed.; Hewitt, John K., Ed.

    This book analyzes the MacArthur Longitudinal Twin Study, a collaborative study by leading developmental scientists and behavioral geneticists on the transition from infancy to early childhood. Part 1 of the book describes the twin method and procedures used and introduces the analytic strategies. Parts 2 through 4 present results related to…

  13. Optimal sampling for radiotelemetry studies of spotted owl habitat and home range.

    Treesearch

    Andrew B. Carey; Scott P. Horton; Janice A. Reid

    1989-01-01

    Radiotelemetry studies of spotted owl (Strix occidentalis) ranges and habitat-use must be designed efficiently to estimate parameters needed for a sample of individuals sufficient to describe the population. Independent data are required by analytical methods and provide the greatest return of information per effort. We examined time series of...

  14. Validation of Multilevel Constructs: Validation Methods and Empirical Findings for the EDI

    ERIC Educational Resources Information Center

    Forer, Barry; Zumbo, Bruno D.

    2011-01-01

    The purposes of this paper are to highlight the foundations of multilevel construct validation, describe two methodological approaches and associated analytic techniques, and then apply these approaches and techniques to the multilevel construct validation of a widely-used school readiness measure called the Early Development Instrument (EDI;…

  15. Description and Recognition of the Concept of Social Capital in Higher Education System

    ERIC Educational Resources Information Center

    Tonkaboni, Forouzan; Yousefy, Alireza; Keshtiaray, Narges

    2013-01-01

    The current research is intended to describe and recognize the concept of social capital in higher education based on theoretical method in a descriptive-analytical approach. Description and Recognition of the data, gathered from theoretical and experimental studies, indicated that social capital is one of the most important indices for…

  16. Establishing and performing targeted multi-residue analysis for lipid mediators and fatty acids in small clinical plasma samples.

    USDA-ARS?s Scientific Manuscript database

    LC-MS/MS and GC-MS based targeted metabolomics is typically conducted by analyzing and quantifying a cascade of metabolites with methods specifically developed for the metabolite class. Here we describe an approach for the development of multi-residue analytical profiles, calibration standards, and ...

  17. Data as the Driver

    ERIC Educational Resources Information Center

    Bechler, Kent L.

    2013-01-01

    In the book "Moneyball: The Art of Winning an Unfair Game," author Michael Lewis describes how the Oakland Athletics, one of the poorest teams in Major League Baseball, became one of the most successful teams by using simple analytical methods that had existed for years but had been largely ignored by the baseball executives. "Moneyball"…

  18. Fatal overdose from Bendectin.

    PubMed

    Bayley, M; Walsh, F M; Valaske, M J

    1975-05-01

    A three-year old male ingested approximately 100 tablets of Bendectin. He developed tonic-clonic seizures followed by cardiac arrest. Toxicologic analysis yielded high levels of doxylamine, dicyclomine, and pyridoxine in blood, peritoneal fluid, and tissue homogenates. The antihistamine, doxylamine succinate appears to be the toxic constituent. Analytical methods used to document the case are herein described.

  19. Cross-Disciplinary Consultancy to Bridge Public Health Technical Needs and Analytic Developers: Asyndromic Surveillance Use Case

    PubMed Central

    Faigen, Zachary; Deyneka, Lana; Ising, Amy; Neill, Daniel; Conway, Mike; Fairchild, Geoffrey; Gunn, Julia; Swenson, David; Painter, Ian; Johnson, Lauren; Kiley, Chris; Streichert, Laura

    2015-01-01

    Introduction: We document a funded effort to bridge the gap between constrained scientific challenges of public health surveillance and methodologies from academia and industry. Component tasks are the collection of epidemiologists’ use case problems, multidisciplinary consultancies to refine them, and dissemination of problem requirements and shareable datasets. We describe an initial use case and consultancy as a concrete example and challenge to developers. Materials and Methods: Supported by the Defense Threat Reduction Agency Biosurveillance Ecosystem project, the International Society for Disease Surveillance formed an advisory group to select tractable use case problems and convene inter-disciplinary consultancies to translate analytic needs into well-defined problems and to promote development of applicable solution methods. The initial consultancy’s focus was a problem originated by the North Carolina Department of Health and its NC DETECT surveillance system: Derive a method for detection of patient record clusters worthy of follow-up based on free-text chief complaints and without syndromic classification. Results: Direct communication between public health problem owners and analytic developers was informative to both groups and constructive for the solution development process. The consultancy achieved refinement of the asyndromic detection challenge and of solution requirements. Participants summarized and evaluated solution approaches and discussed dissemination and collaboration strategies. Practice Implications: A solution meeting the specification of the use case described above could improve human monitoring efficiency with expedited warning of events requiring follow-up, including otherwise overlooked events with no syndromic indicators. This approach can remove obstacles to collaboration with efficient, minimal data-sharing and without costly overhead. PMID:26834939

  20. Two Approaches in the Lunar Libration Theory: Analytical vs. Numerical Methods

    NASA Astrophysics Data System (ADS)

    Petrova, Natalia; Zagidullin, Arthur; Nefediev, Yurii; Kosulin, Valerii

    2016-10-01

    Observation of the physical libration of the Moon and the celestial bodies is one of the astronomical methods to remotely evaluate the internal structure of a celestial body without using expensive space experiments. Review of the results obtained due to the physical libration study, is presented in the report.The main emphasis is placed on the description of successful lunar laser ranging for libration determination and on the methods of simulating the physical libration. As a result, estimation of the viscoelastic and dissipative properties of the lunar body, of the lunar core parameters were done. The core's existence was confirmed by the recent reprocessing of seismic data Apollo missions. Attention is paid to the physical interpretation of the phenomenon of free libration and methods of its determination.A significant part of the report is devoted to describing the practical application of the most accurate to date the analytical tables of lunar libration built by comprehensive analytical processing of residual differences obtained when comparing the long-term series of laser observations with numerical ephemeris DE421 [1].In general, the basic outline of the report reflects the effectiveness of two approaches in the libration theory - numerical and analytical solution. It is shown that the two approaches complement each other for the study of the Moon in different aspects: numerical approach provides high accuracy of the theory necessary for adequate treatment of modern high-accurate observations and the analytic approach allows you to see the essence of the various kind manifestations in the lunar rotation, predict and interpret the new effects in observations of physical libration [2].[1] Rambaux, N., J. G. Williams, 2011, The Moon's physical librations and determination of their free modes, Celest. Mech. Dyn. Astron., 109, 85-100.[2] Petrova N., A. Zagidullin, Yu. Nefediev. Analysis of long-periodic variations of lunar libration parameters on the basis of analytical theory / // The Russian-Japanese Workshop, 20-25 October, Tokyo (Mitaka) - Mizusawa, Japan. - 2014.

  1. Temperature dependent nonlinear metal matrix laminae behavior

    NASA Technical Reports Server (NTRS)

    Barrett, D. J.; Buesking, K. W.

    1986-01-01

    An analytical method is described for computing the nonlinear thermal and mechanical response of laminated plates. The material model focuses upon the behavior of metal matrix materials by relating the nonlinear composite response to plasticity effects in the matrix. The foundation of the analysis is the unidirectional material model which is used to compute the instantaneous properties of the lamina based upon the properties of the fibers and matrix. The unidirectional model assumes that the fibers properties are constant with temperature and assumes that the matrix can be modelled as a temperature dependent, bilinear, kinematically hardening material. An incremental approach is used to compute average stresses in the fibers and matrix caused by arbitrary mechanical and thermal loads. The layer model is incorporated in an incremental laminated plate theory to compute the nonlinear response of laminated metal matrix composites of general orientation and stacking sequence. The report includes comparisons of the method with other analytical approaches and compares theoretical calculations with measured experimental material behavior. A section is included which describes the limitations of the material model.

  2. Using analytic hierarchy process approach in ontological multicriterial decision making - Preliminary considerations

    NASA Astrophysics Data System (ADS)

    Wasielewska, K.; Ganzha, M.

    2012-10-01

    In this paper we consider combining ontologically demarcated information with Saaty's Analytic Hierarchy Process (AHP) [1] for the multicriterial assessment of offers during contract negotiations. The context for the proposal is provided by the Agents in Grid project (AiG; [2]), which aims at development of an agent-based infrastructure for efficient resource management in the Grid. In the AiG project, software agents representing users can either (1) join a team and earn money, or (2) find a team to execute a job. Moreover, agents form teams, managers of which negotiate with clients and workers terms of potential collaboration. Here, ontologically described contracts (Service Level Agreements) are the results of autonomous multiround negotiations. Therefore, taking into account relatively complex nature of the negotiated contracts, multicriterial assessment of proposals plays a crucial role. The AHP method is based on pairwise comparisons of criteria and relies on the judgement of a panel of experts. It measures how well does an offer serve the objective of a decision maker. In this paper, we propose how the AHP method can be used to assess ontologically described contract proposals.

  3. A General Simulation Method for Multiple Bodies in Proximate Flight

    NASA Technical Reports Server (NTRS)

    Meakin, Robert L.

    2003-01-01

    Methods of unsteady aerodynamic simulation for an arbitrary number of independent bodies flying in close proximity are considered. A novel method to efficiently detect collision contact points is described. A method to compute body trajectories in response to aerodynamic loads, applied loads, and inter-body collisions is also given. The physical correctness of the methods are verified by comparison to a set of analytic solutions. The methods, combined with a Navier-Stokes solver, are used to demonstrate the possibility of predicting the unsteady aerodynamics and flight trajectories of moving bodies that involve rigid-body collisions.

  4. Choosing and Using Introns in Molecular Phylogenetics

    PubMed Central

    Creer, Simon

    2007-01-01

    Introns are now commonly used in molecular phylogenetics in an attempt to recover gene trees that are concordant with species trees, but there are a range of genomic, logistical and analytical considerations that are infrequently discussed in empirical studies that utilize intron data. This review outlines expedient approaches for locus selection, overcoming paralogy problems, recombination detection methods and the identification and incorporation of LVHs in molecular systematics. A range of parsimony and Bayesian analytical approaches are also described in order to highlight the methods that can currently be employed to align sequences and treat indels in subsequent analyses. By covering the main points associated with the generation and analysis of intron data, this review aims to provide a comprehensive introduction to using introns (or any non-coding nuclear data partition) in contemporary phylogenetics. PMID:19461984

  5. "Cork taint" responsible compounds. Determination of haloanisoles and halophenols in cork matrix: A review.

    PubMed

    Tarasov, Andrii; Rauhut, Doris; Jung, Rainer

    2017-12-01

    Analytical methods of haloanisoles and halophenols quantification in cork matrix are summarized in the current review. Sample-preparation and sample-treatment techniques have been compared and discussed from the perspective of their efficiency, time- and extractant-optimization, easiness of performance. Primary interest of these analyses usually addresses to 2,4,6-trichloroanisole (TCA), which is a major wine contaminant among haloanisoles. Two concepts of TCA determination are described in the review: releasable TCA and total TCA analyses. Chromatographic, bioanalytical and sensorial methods were compared according to their application in the cork industry and in scientific investigations. Finally, it was shown that modern analytical techniques are able to provide required sensitivity, selectivity and repeatability for haloanisoles and halophenols determination. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Development of an analytical procedure to study linear alkylbenzenesulphonate (LAS) degradation in sewage sludge-amended soils.

    PubMed

    Comellas, L; Portillo, J L; Vaquero, M T

    1993-12-24

    A procedure for determining linear alkylbenzenesulphonates (LASs) in sewage sludge and amended soils has been developed. Extraction by sample treatment with 0.5 M potassium hydroxide in methanol and reflux was compared with a previously described extraction procedure in Soxhlet with methanol and solid sodium hydroxide in the sample. Repeatability results were similar with savings in extraction time, solvents and evaporation time. A clean-up method involving a C18 cartridge has been developed. Analytes were quantified by a reversed-phase HPLC method with UV and fluorescence detectors. Recoveries obtained were higher than 84%. The standing procedure was applied to high doses of sewage sludge-amended soils (15%) with increasing quantities of added LASs. Degradation data for a 116-day period are presented.

  7. On the line-shape analysis of Compton profiles and its application to neutron scattering

    NASA Astrophysics Data System (ADS)

    Romanelli, G.; Krzystyniak, M.

    2016-05-01

    Analytical properties of Compton profiles are used in order to simplify the analysis of neutron Compton scattering experiments. In particular, the possibility to fit the difference of Compton profiles is discussed as a way to greatly decrease the level of complexity of the data treatment, making the analysis easier, faster and more robust. In the context of the novel method proposed, two mathematical models describing the shapes of differenced Compton profiles are discussed: the simple Gaussian approximation for harmonic and isotropic local potential, and an analytical Gauss-Hermite expansion for an anharmonic or anisotropic potential. The method is applied to data collected by VESUVIO spectrometer at ISIS neutron and muon pulsed source (UK) on Copper and Aluminium samples at ambient and low temperatures.

  8. Collapse of ultrashort spatiotemporal pulses described by the cubic generalized Kadomtsev-Petviashvili equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leblond, Herve; Kremer, David; Mihalache, Dumitru

    2010-03-15

    By using a reductive perturbation method, we derive from Maxwell-Bloch equations a cubic generalized Kadomtsev-Petviashvili equation for ultrashort spatiotemporal optical pulse propagation in cubic (Kerr-like) media without the use of the slowly varying envelope approximation. We calculate the collapse threshold for the propagation of few-cycle spatiotemporal pulses described by the generic cubic generalized Kadomtsev-Petviashvili equation by a direct numerical method and compare it to analytic results based on a rigorous virial theorem. Besides, typical evolution of the spectrum (integrated over the transverse spatial coordinate) is given and a strongly asymmetric spectral broadening of ultrashort spatiotemporal pulses during collapse is evidenced.

  9. The uniform asymptotic swallowtail approximation - Practical methods for oscillating integrals with four coalescing saddle points

    NASA Technical Reports Server (NTRS)

    Connor, J. N. L.; Curtis, P. R.; Farrelly, D.

    1984-01-01

    Methods that can be used in the numerical implementation of the uniform swallowtail approximation are described. An explicit expression for that approximation is presented to the lowest order, showing that there are three problems which must be overcome in practice before the approximation can be applied to any given problem. It is shown that a recently developed quadrature method can be used for the accurate numerical evaluation of the swallowtail canonical integral and its partial derivatives. Isometric plots of these are presented to illustrate some of their properties. The problem of obtaining the arguments of the swallowtail integral from an analytical function of its argument is considered, describing two methods of solving this problem. The asymptotic evaluation of the butterfly canonical integral is addressed.

  10. Single-step transesterification with simultaneous concentration and stable isotope analysis of fatty acid methyl esters by gas chromatography-combustion-isotope ratio mass spectrometry.

    PubMed

    Panetta, Robert J; Jahren, A Hope

    2011-05-30

    Gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) is increasingly applied to food and metabolic studies for stable isotope analysis (δ(13) C), with the quantification of analyte concentration often obtained via a second alternative method. We describe a rapid direct transesterification of triacylglycerides (TAGs) for fatty acid methyl ester (FAME) analysis by GC-C-IRMS demonstrating robust simultaneous quantification of amount of analyte (mean r(2) =0.99, accuracy ±2% for 37 FAMEs) and δ(13) C (±0.13‰) in a single analytical run. The maximum FAME yield and optimal δ(13) C values are obtained by derivatizing with 10% (v/v) acetyl chloride in methanol for 1 h, while lower levels of acetyl chloride and shorter reaction times skewed the δ(13) C values by as much as 0.80‰. A Bland-Altman evaluation of the GC-C-IRMS measurements resulted in excellent agreement for pure oils (±0.08‰) and oils extracted from French fries (±0.49‰), demonstrating reliable simultaneous quantification of FAME concentration and δ(13) C values. Thus, we conclude that for studies requiring both the quantification of analyte and δ(13) C data, such as authentication or metabolic flux studies, GC-C-IRMS can be used as the sole analytical method. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Quantitative Methods Based on Twisted Nematic Liquid Crystals for Mapping Surfaces Patterned with Bio/Chemical Functionality Relevant to Bioanalytical Assays

    PubMed Central

    Lowe, Aaron M.; Bertics, Paul J.; Abbott, Nicholas L.

    2009-01-01

    We report methods for the acquisition and analysis of optical images formed by thin films of twisted nematic liquid crystals (LCs) placed into contact with surfaces patterned with bio/chemical functionality relevant to surface-based assays. The methods are simple to implement and are shown to provide easily interpreted maps of chemical transformations on surfaces that are widely exploited in the preparation of analytic devices. The methods involve acquisition of multiple images of the LC as a function of the orientation of a polarizer; data analysis condenses the information present in the stack of images into a spatial map of the twist angle of the LC on the analytic surface. The potential utility of the methods is illustrated by mapping (i) the displacement of a monolayer formed from one alkanethiol on a gold film by a second thiol in solution, (ii) coadsorption of mixtures of amine-terminated and ethyleneglycol-terminated alkanethiols on gold films, which leads to a type of mixed monolayer that is widely exploited for immobilization of proteins on analytic surfaces, and (iii) patterns of antibodies printed onto surfaces. These results show that maps of the twist angle of the LC constructed from families of optical images can be used to reveal surface features that are not apparent in a single image of the LC film. Furthermore, the twist angles of the LC can be used to quantify the energy of interaction of the LC with the surface with a spatial resolution of <10 µm. When combined, the results described in this paper suggest non-destructive methods to monitor and validate chemical transformations on surfaces of the type that are routinely employed in the preparation of surface-based analytic technologies. PMID:18355089

  12. Advantages of using tetrahydrofuran-water as mobile phases in the quantitation of cyclosporin A in monkey and rat plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Austin C; Li, Yinghe; Guirguis, Micheal S; Caldwell, Robert G; Shou, Wilson Z

    2007-01-04

    A new analytical method is described here for the quantitation of anti-inflammatory drug cyclosporin A (CyA) in monkey and rat plasma. The method used tetrahydrofuran (THF)-water mobile phases to elute the analyte and internal standard, cyclosporin C (CyC). The gradient mobile phase program successfully eluted CyA into a sharp peak and therefore improved resolution between the analyte and possible interfering materials compared with previously reported analytical approaches, where CyA was eluted as a broad peak due to the rapid conversion between different conformers. The sharp peak resulted from this method facilitated the quantitative calculation as multiple smoothing and large number of bunching factors were not necessary. The chromatography in the new method was performed at 30 degrees C instead of 65-70 degrees C as reported previously. Other advantages of the method included simple and fast sample extraction-protein precipitation, direct injection of the extraction supernatant to column for analysis, and elimination of evaporation and reconstitution steps, which were needed in solid phase extraction or liquid-liquid extraction reported before. This method is amenable to high-throughput analysis with a total chromatographic run time of 3 min. This approach has been verified as sensitive, linear (0.977-4000 ng/mL), accurate and precise for the quantitation of CyA in monkey and rat plasma. However, compared with the usage of conventional mobile phases, the only drawback of this approach was the reduced detection response from the mass spectrometer that was possibly caused by poor desolvation in the ionization source. This is the first report to demonstrate the advantages of using THF-water mobile phases to elute CyA in liquid chromatography.

  13. Freak oscillation in a dusty plasma.

    PubMed

    Zhang, Heng; Yang, Yang; Hong, Xue-Ren; Qi, Xin; Duan, Wen-Shan; Yang, Lei

    2017-05-01

    The freak oscillation in one-dimensional dusty plasma is studied numerically by particle-in-cell method. Using a perturbation method, the basic set of fluid equations is reduced to a nonlinear Schrödinger equation (NLSE). The rational solution of the NLSE is presented, which is proposed as an effective tool for studying the rogue waves in dusty plasma. Additionally, the application scope of the analytical solution of the rogue wave described by the NLSE is given.

  14. Using Hybrid Simulation/Analytical Queueing Networks to Capacitate USAF Air Mobility Command Passenger Terminals

    DTIC Science & Technology

    2012-03-01

    Simulation Simulation is a flexible tool for modeling airport operations , which has made the method a staple for airport systems analysts. Animation...be derived to define the character- istics of the airport terminal and describe the nature of the systems [sic] operation ”, which makes discrete...This system decomposition method, however, disregards the effects of network structure on performance measures. Real-life processes do not operate

  15. Geovisual analytics to enhance spatial scan statistic interpretation: an analysis of U.S. cervical cancer mortality.

    PubMed

    Chen, Jin; Roth, Robert E; Naito, Adam T; Lengerich, Eugene J; Maceachren, Alan M

    2008-11-07

    Kulldorff's spatial scan statistic and its software implementation - SaTScan - are widely used for detecting and evaluating geographic clusters. However, two issues make using the method and interpreting its results non-trivial: (1) the method lacks cartographic support for understanding the clusters in geographic context and (2) results from the method are sensitive to parameter choices related to cluster scaling (abbreviated as scaling parameters), but the system provides no direct support for making these choices. We employ both established and novel geovisual analytics methods to address these issues and to enhance the interpretation of SaTScan results. We demonstrate our geovisual analytics approach in a case study analysis of cervical cancer mortality in the U.S. We address the first issue by providing an interactive visual interface to support the interpretation of SaTScan results. Our research to address the second issue prompted a broader discussion about the sensitivity of SaTScan results to parameter choices. Sensitivity has two components: (1) the method can identify clusters that, while being statistically significant, have heterogeneous contents comprised of both high-risk and low-risk locations and (2) the method can identify clusters that are unstable in location and size as the spatial scan scaling parameter is varied. To investigate cluster result stability, we conducted multiple SaTScan runs with systematically selected parameters. The results, when scanning a large spatial dataset (e.g., U.S. data aggregated by county), demonstrate that no single spatial scan scaling value is known to be optimal to identify clusters that exist at different scales; instead, multiple scans that vary the parameters are necessary. We introduce a novel method of measuring and visualizing reliability that facilitates identification of homogeneous clusters that are stable across analysis scales. Finally, we propose a logical approach to proceed through the analysis of SaTScan results. The geovisual analytics approach described in this manuscript facilitates the interpretation of spatial cluster detection methods by providing cartographic representation of SaTScan results and by providing visualization methods and tools that support selection of SaTScan parameters. Our methods distinguish between heterogeneous and homogeneous clusters and assess the stability of clusters across analytic scales. We analyzed the cervical cancer mortality data for the United States aggregated by county between 2000 and 2004. We ran SaTScan on the dataset fifty times with different parameter choices. Our geovisual analytics approach couples SaTScan with our visual analytic platform, allowing users to interactively explore and compare SaTScan results produced by different parameter choices. The Standardized Mortality Ratio and reliability scores are visualized for all the counties to identify stable, homogeneous clusters. We evaluated our analysis result by comparing it to that produced by other independent techniques including the Empirical Bayes Smoothing and Kafadar spatial smoother methods. The geovisual analytics approach introduced here is developed and implemented in our Java-based Visual Inquiry Toolkit.

  16. Advances in aptamer screening and small molecule aptasensors.

    PubMed

    Kim, Yeon Seok; Gu, Man Bock

    2014-01-01

    It has been 20 years since aptamer and SELEX (systematic evolution of ligands by exponential enrichment) were described independently by Andrew Ellington and Larry Gold. Based on the great advantages of aptamers, there have been numerous isolated aptamers for various targets that have actively been applied as therapeutic and analytical tools. Over 2,000 papers related to aptamers or SELEX have been published, attesting to their wide usefulness and the applicability of aptamers. SELEX methods have been modified or re-created over the years to enable aptamer isolation with higher affinity and selectivity in more labor- and time-efficient manners, including automation. Initially, most of the studies about aptamers have focused on the protein targets, which have physiological functions in the body, and their applications as therapeutic agents or receptors for diagnostics. However, aptamers for small molecules such as organic or inorganic compounds, drugs, antibiotics, or metabolites have not been studied sufficiently, despite the ever-increasing need for rapid and simple analytical methods for various chemical targets in the fields of medical diagnostics, environmental monitoring, food safety, and national defense against targets including chemical warfare. This review focuses on not only recent advances in aptamer screening methods but also its analytical application for small molecules.

  17. An analytical method for predicting the geometrical and optical properties of the human lens under accommodation

    PubMed Central

    Sheil, Conor J.; Bahrami, Mehdi; Goncharov, Alexander V.

    2014-01-01

    We present an analytical method to describe the accommodative changes in the human crystalline lens. The method is based on the geometry-invariant lens model, in which the gradient-index (GRIN) iso-indicial contours are coupled to the external shape. This feature ensures that any given number of iso-indicial contours does not change with accommodation, which preserves the optical integrity of the GRIN structure. The coupling also enables us to define the GRIN structure if the radii and asphericities of the external lens surfaces are known. As an example, the accommodative changes in lenticular radii and central thickness were taken from the literature, while the asphericities of the external surfaces were derived analytically by adhering to the basic physical conditions of constant lens volume and its axial position. The resulting changes in lens geometry are consistent with experimental data, and the optical properties are in line with expected values for optical power and spherical aberration. The aim of the paper is to provide an anatomically and optically accurate lens model that is valid for 3 mm pupils and can be used as a new tool for better understanding of accommodation. PMID:24877022

  18. An analytical method for predicting the geometrical and optical properties of the human lens under accommodation.

    PubMed

    Sheil, Conor J; Bahrami, Mehdi; Goncharov, Alexander V

    2014-05-01

    We present an analytical method to describe the accommodative changes in the human crystalline lens. The method is based on the geometry-invariant lens model, in which the gradient-index (GRIN) iso-indicial contours are coupled to the external shape. This feature ensures that any given number of iso-indicial contours does not change with accommodation, which preserves the optical integrity of the GRIN structure. The coupling also enables us to define the GRIN structure if the radii and asphericities of the external lens surfaces are known. As an example, the accommodative changes in lenticular radii and central thickness were taken from the literature, while the asphericities of the external surfaces were derived analytically by adhering to the basic physical conditions of constant lens volume and its axial position. The resulting changes in lens geometry are consistent with experimental data, and the optical properties are in line with expected values for optical power and spherical aberration. The aim of the paper is to provide an anatomically and optically accurate lens model that is valid for 3 mm pupils and can be used as a new tool for better understanding of accommodation.

  19. The work of the European Union Reference Laboratory for Food Additives (EURL) and its support for the authorisation process of feed additives in the European Union: a review

    PubMed Central

    von Holst, Christoph; Robouch, Piotr; Bellorini, Stefano; de la Huebra, María José González; Ezerskis, Zigmas

    2016-01-01

    ABSTRACT This paper describes the operation of the European Union Reference Laboratory for Feed Additives (EURL) and its role in the authorisation procedure of feed additives in the European Union. Feed additives are authorised according to Regulation (EC) No. 1831/2003, which introduced a completely revised authorisation procedure and also established the EURL. The regulations authorising feed additives contain conditions of use such as legal limits of the feed additives, which require the availability of a suitable method of analysis for official control purposes under real world conditions. It is the task of the EURL to evaluate the suitability of analytical methods as proposed by the industry for this purpose. Moreover, the paper shows that one of the major challenges is the huge variety of the methodology applied in feed additive analysis, thus requiring expertise in quite different analytical areas. In order to cope with this challenge, the EURL is supported by a network of national reference laboratories (NRLs) and only the merged knowledge of all NRLs allows for a scientifically sound assessment of the analytical methods. PMID:26540604

  20. Quantification of trans-1,4-polyisoprene in Eucommia ulmoides by fourier transform infrared spectroscopy and pyrolysis-gas chromatography/mass spectrometry.

    PubMed

    Takeno, Shinya; Bamba, Takeshi; Nakazawa, Yoshihisa; Fukusaki, Eiichiro; Okazawa, Atsushi; Kobayashi, Akio

    2008-04-01

    Commercial development of trans-1,4-polyisoprene from Eucommia ulmoides Oliver (EU-rubber) requires specific knowledge on selection of high-rubber-content lines and establishment of agronomic cultivation methods for achieving maximum EU-rubber yield. The development can be facilitated by high-throughput and highly sensitive analytical techniques for EU-rubber extraction and quantification. In this paper, we described an efficient EU-rubber extraction method, and validated that the accuracy was equivalent to that of the conventional Soxhlet extraction method. We also described a highly sensitive quantification method for EU-rubber by Fourier transform infrared spectroscopy (FT-IR) and pyrolysis-gas chromatography/mass spectrometry (PyGC/MS). We successfully applied the extraction/quantification method for study of seasonal changes in EU-rubber content and molecular weight distribution.

  1. Liquid chromatography-tandem mass spectrometry analysis of perfluorooctane sulfonate and perfluorooctanoic Acid in fish fillet samples.

    PubMed

    Paiano, Viviana; Fattore, Elena; Carrà, Andrea; Generoso, Caterina; Fanelli, Roberto; Bagnati, Renzo

    2012-01-01

    Perfluorooctane sulfonate (PFOS) and perfluorooctanoic (PFOA) acid are persistent contaminants which can be found in environmental and biological samples. A new and fast analytical method is described here for the analysis of these compounds in the edible part of fish samples. The method uses a simple liquid extraction by sonication, followed by a direct determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The linearity of the instrumental response was good, with average regression coefficients of 0.9971 and 0.9979 for PFOS and PFOA, respectively, and the coefficients of variation (CV) of the method ranged from 8% to 20%. Limits of detection (LOD) were 0.04 ng/g for both the analytes and recoveries were 90% for PFOS and 76% for PFOA. The method was applied to samples of homogenized fillets of wild and farmed fish from the Mediterranean Sea. Most of the samples showed little or no contamination by perfluorooctane sulfonate and perfluorooctanoic acid, and the highest concentrations detected among the fish species analyzed were, respectively, 5.96 ng/g and 1.89 ng/g. The developed analytical methodology can be used as a tool to monitor and to assess human exposure to perfluorinated compounds through sea food consumption.

  2. Detection of nanomaterials in food and consumer products: bridging the gap from legislation to enforcement.

    PubMed

    Stamm, H; Gibson, N; Anklam, E

    2012-08-01

    This paper describes the requirements and resulting challenges for the implementation of current and upcoming European Union legislation referring to the use of nanomaterials in food, cosmetics and other consumer products. The European Commission has recently adopted a recommendation for the definition of nanomaterials. There is now an urgent need for appropriate and fit-for-purpose analytical methods in order to identify nanomaterials properly according to this definition and to assess whether or not a product contains nanomaterials. Considering the lack of such methods to date, this paper elaborates on the challenges of the legislative framework and the type of methods needed, not only to facilitate implementation of labelling requirements, but also to ensure the safety of products coming to the market. Considering the many challenges in the analytical process itself, such as interaction of nanoparticles with matrix constituents, potential agglomeration and aggregation due to matrix environment, broad variety of matrices, etc., there is a need for integrated analytical approaches, not only for sample preparation (e.g. separation from matrix), but also for the actual characterisation. Furthermore, there is an urgent need for quality assurance tools such as validated methods and (certified) reference materials, including materials containing nanoparticles in a realistic matrix (food products, cosmetics, etc.).

  3. Model-free and analytical EAP reconstruction via spherical polar Fourier diffusion MRI.

    PubMed

    Cheng, Jian; Ghosh, Aurobrata; Jiang, Tianzi; Deriche, Rachid

    2010-01-01

    How to estimate the diffusion Ensemble Average Propagator (EAP) from the DWI signals in q-space is an open problem in diffusion MRI field. Many methods were proposed to estimate the Orientation Distribution Function (ODF) that is used to describe the fiber direction. However, ODF is just one of the features of the EAP. Compared with ODF, EAP has the full information about the diffusion process which reflects the complex tissue micro-structure. Diffusion Orientation Transform (DOT) and Diffusion Spectrum Imaging (DSI) are two important methods to estimate the EAP from the signal. However, DOT is based on mono-exponential assumption and DSI needs a lot of samplings and very large b values. In this paper, we propose Spherical Polar Fourier Imaging (SPFI), a novel model-free fast robust analytical EAP reconstruction method, which almost does not need any assumption of data and does not need too many samplings. SPFI naturally combines the DWI signals with different b-values. It is an analytical linear transformation from the q-space signal to the EAP profile represented by Spherical Harmonics (SH). We validated the proposed methods in synthetic data, phantom data and real data. It works well in all experiments, especially for the data with low SNR, low anisotropy, and non-exponential decay.

  4. An automated protocol for performance benchmarking a widefield fluorescence microscope.

    PubMed

    Halter, Michael; Bier, Elianna; DeRose, Paul C; Cooksey, Gregory A; Choquette, Steven J; Plant, Anne L; Elliott, John T

    2014-11-01

    Widefield fluorescence microscopy is a highly used tool for visually assessing biological samples and for quantifying cell responses. Despite its widespread use in high content analysis and other imaging applications, few published methods exist for evaluating and benchmarking the analytical performance of a microscope. Easy-to-use benchmarking methods would facilitate the use of fluorescence imaging as a quantitative analytical tool in research applications, and would aid the determination of instrumental method validation for commercial product development applications. We describe and evaluate an automated method to characterize a fluorescence imaging system's performance by benchmarking the detection threshold, saturation, and linear dynamic range to a reference material. The benchmarking procedure is demonstrated using two different materials as the reference material, uranyl-ion-doped glass and Schott 475 GG filter glass. Both are suitable candidate reference materials that are homogeneously fluorescent and highly photostable, and the Schott 475 GG filter glass is currently commercially available. In addition to benchmarking the analytical performance, we also demonstrate that the reference materials provide for accurate day to day intensity calibration. Published 2014 Wiley Periodicals Inc. Published 2014 Wiley Periodicals Inc. This article is a US government work and, as such, is in the public domain in the United States of America.

  5. Design and fabrication of planar structures with graded electromagnetic properties

    NASA Astrophysics Data System (ADS)

    Good, Brandon Lowell

    Successfully integrating electromagnetic properties in planar structures offers numerous benefits to the microwave and optical communities. This work aims at formulating new analytic and optimized design methods, creating new fabrication techniques for achieving those methods, and matching appropriate implementation of methods to fabrication techniques. The analytic method consists of modifying an approach that realizes perfect antireflective properties from graded profiles. This method is shown for all-dielectric and magneto-dielectric grading profiles. The optimized design methods are applied to transformer (discrete) or taper (continuous) designs. From these methods, a subtractive and an additive manufacturing technique were established and are described. The additive method, dry powder dot deposition, enables three dimensional varying electromagnetic properties in a structural composite. Combining the methods and fabrication is shown in two applied methodologies. The first uses dry powder dot deposition to design one dimensionally graded electromagnetic profiles in a planar fiberglass composite. The second method simultaneously applies antireflective properties and adjusts directivity through a slab through the use of subwavelength structures to achieve a flat antireflective lens. The end result of this work is a complete set of methods, formulations, and fabrication techniques to achieve integrated electromagnetic properties in planar structures.

  6. Superstatistics model for T₂ distribution in NMR experiments on porous media.

    PubMed

    Correia, M D; Souza, A M; Sinnecker, J P; Sarthour, R S; Santos, B C C; Trevizan, W; Oliveira, I S

    2014-07-01

    We propose analytical functions for T2 distribution to describe transverse relaxation in high- and low-fields NMR experiments on porous media. The method is based on a superstatistics theory, and allows to find the mean and standard deviation of T2, directly from measurements. It is an alternative to multiexponential models for data decay inversion in NMR experiments. We exemplify the method with q-exponential functions and χ(2)-distributions to describe, respectively, data decay and T2 distribution on high-field experiments of fully water saturated glass microspheres bed packs, sedimentary rocks from outcrop and noisy low-field experiment on rocks. The method is general and can also be applied to biological systems. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Reverse Transcription Quantitative Polymerase Chain Reaction for Detection of and Differentiation Between RNA and DNA of HIV-1-Based Lentiviral Vectors.

    PubMed

    Pavlovic, Melanie; Koehler, Nina; Anton, Martina; Dinkelmeier, Anna; Haase, Maren; Stellberger, Thorsten; Busch, Ulrich; Baiker, Armin E

    2017-08-01

    The purpose of the described method is the detection of and differentiation between RNA and DNA of human immunodeficiency virus (HIV)-derived lentiviral vectors (LV) in cell culture supernatants and swab samples. For the analytical surveillance of genetic engineering, operations methods for the detection of the HIV-1-based LV generations are required. Furthermore, for research issues, it is important to prove the absence of LV particles for downgrading experimental settings in terms of the biosafety level. Here, a quantitative polymerase chain reaction method targeting the long terminal repeat U5 subunit and the start sequence of the packaging signal ψ is described. Numerous controls are included in order to monitor the technical procedure.

  8. Big data analytics to improve cardiovascular care: promise and challenges.

    PubMed

    Rumsfeld, John S; Joynt, Karen E; Maddox, Thomas M

    2016-06-01

    The potential for big data analytics to improve cardiovascular quality of care and patient outcomes is tremendous. However, the application of big data in health care is at a nascent stage, and the evidence to date demonstrating that big data analytics will improve care and outcomes is scant. This Review provides an overview of the data sources and methods that comprise big data analytics, and describes eight areas of application of big data analytics to improve cardiovascular care, including predictive modelling for risk and resource use, population management, drug and medical device safety surveillance, disease and treatment heterogeneity, precision medicine and clinical decision support, quality of care and performance measurement, and public health and research applications. We also delineate the important challenges for big data applications in cardiovascular care, including the need for evidence of effectiveness and safety, the methodological issues such as data quality and validation, and the critical importance of clinical integration and proof of clinical utility. If big data analytics are shown to improve quality of care and patient outcomes, and can be successfully implemented in cardiovascular practice, big data will fulfil its potential as an important component of a learning health-care system.

  9. How to conduct External Quality Assessment Schemes for the pre-analytical phase?

    PubMed

    Kristensen, Gunn B B; Aakre, Kristin Moberg; Kristoffersen, Ann Helen; Sandberg, Sverre

    2014-01-01

    In laboratory medicine, several studies have described the most frequent errors in the different phases of the total testing process, and a large proportion of these errors occur in the pre-analytical phase. Schemes for registration of errors and subsequent feedback to the participants have been conducted for decades concerning the analytical phase by External Quality Assessment (EQA) organizations operating in most countries. The aim of the paper is to present an overview of different types of EQA schemes for the pre-analytical phase, and give examples of some existing schemes. So far, very few EQA organizations have focused on the pre-analytical phase, and most EQA organizations do not offer pre-analytical EQA schemes (EQAS). It is more difficult to perform and standardize pre-analytical EQAS and also, accreditation bodies do not ask the laboratories for results from such schemes. However, some ongoing EQA programs for the pre-analytical phase do exist, and some examples are given in this paper. The methods used can be divided into three different types; collecting information about pre-analytical laboratory procedures, circulating real samples to collect information about interferences that might affect the measurement procedure, or register actual laboratory errors and relate these to quality indicators. These three types have different focus and different challenges regarding implementation, and a combination of the three is probably necessary to be able to detect and monitor the wide range of errors occurring in the pre-analytical phase.

  10. Improved DNA hybridization parameters by Twisted Intercalating Nucleic Acid (TINA).

    PubMed

    Schneider, Uffe Vest

    2012-01-01

    This thesis establishes oligonucleotide design rules and applications of a novel group of DNA stabilizing molecules collectively called Twisted Intercalating Nucleic Acid - TINA. Three peer-reviewed publications form the basis for the thesis. One publication describes an improved and rapid method for determination of DNA melting points and two publications describe the effects of positioning TINA molecules in parallel triplex helix and antiparallel duplex helix forming DNA structures. The third publication establishes that TINA molecules containing oligonucleotides improve an antiparallel duplex hybridization based capture assay's analytical sensitivity compared to conventionel DNA oligonucleotides. Clinical microbiology is traditionally based on pathogenic microorganisms' culture and serological tests. The introduction of DNA target amplification methods like PCR has improved the analytical sensitivity and total turn around time involved in clinical diagnostics of infections. Due to the relatively weak hybridization between the two strands of double stranded DNA, a number of nucleic acid stabilizing molecules have been developed to improve the sensitivity of DNA based diagnostics through superior binding properties. A short introduction is given to Watson-Crick and Hoogsteen based DNA binding and the derived DNA structures. A number of other nucleic acid stabilizing molecules are described. The stabilizing effect of TINA molecules on different DNA structures is discussed and considered in relation to other nucleic acid stabilizing molecules and in relation to future use of TINA containing oligonucleotides in clinical diagnostics and therapy. In conclusion, design of TINA modified oligonucleotides for antiparallel duplex helixes and parallel triplex helixes follows simple purpose dependent rules. TINA molecules are well suited for improving multiplex PCR assays and can be used as part of novel technologies. Future research should test whether combinations of TINA molecules and other nucleic acid stabilizing molecules can increase analytical sensitivity whilst maintaining nucleobase mismatch discrimination in triplex helix based diagnostic assays.

  11. Effect of analytical conditions in wavelength dispersive electron microprobe analysis on the measurement of strontium-to-calcium (Sr/Ca) ratios in otoliths of anadromous salmonids

    USGS Publications Warehouse

    Zimmerman, Christian E.; Nielsen, Roger L.

    2003-01-01

    The use of strontium-to-calcium (Sr/Ca) ratios in otoliths is becoming a standard method to describe life history type and the chronology of migrations between freshwater and seawater habitats in teleosts (e.g. Kalish, 1990; Radtke et al., 1990; Secor, 1992; Rieman et al., 1994; Radtke, 1995; Limburg, 1995; Tzeng et al. 1997; Volk et al., 2000; Zimmerman, 2000; Zimmerman and Reeves, 2000, 2002). This method provides critical information concerning the relationship and ecology of species exhibiting phenotypic variation in migratory behavior (Kalish, 1990; Secor, 1999). Methods and procedures, however, vary among laboratories because a standard method or protocol for measurement of Sr in otoliths does not exist. In this note, we examine the variations in analytical conditions in an effort to increase precision of Sr/Ca measurements. From these findings we argue that precision can be maximized with higher beam current (although there is specimen damage) than previously recommended by Gunn et al. (1992).

  12. Ultrasonication extraction and gel permeation chromatography clean-up for the determination of polycyclic aromatic hydrocarbons in edible oil by an isotope dilution gas chromatography–mass spectrometry.

    PubMed

    Wang, Jian-Hua; Guo, Cui

    2010-07-09

    An analytical method for the determination of US EPA priority pollutant 16 polycyclic aromatic hydrocarbons (PAHs) in edible oil was developed by an isotope dilution gas chromatography-mass spectrometry (GC-MS). Extraction was performed with ultrasonication mode using acetonitrile as solvent, and subsequent clean-up was applied using narrow gel permeation chromatographic column. Three deuterated PAHs surrogate standards were used as internal standards for quantification and analytical quality control. The limits of quantification (LOQs) were globally below 0.5 ng/g, the recoveries were in the range of 81-96%, and the relative standard deviations (RSDs) were lower than 20%. Further trueness assessment of the method was also verified through participation in international cocoa butter proficiency test (T0638) organised by the FAPAS with excellent results in 2008. The results obtained with the described method were satisfying (z ≤ 2). The method has been applied to determine PAH in real edible oil samples.

  13. The induction of mycotoxins by trichothecene producing Fusarium species.

    PubMed

    Lowe, Rohan; Jubault, Mélanie; Canning, Gail; Urban, Martin; Hammond-Kosack, Kim E

    2012-01-01

    In recent years, many Fusarium species have emerged which now threaten the productivity and safety of small grain cereal crops worldwide. During floral infection and post-harvest on stored grains the Fusarium hyphae produce various types of harmful mycotoxins which subsequently contaminate food and feed products. This article focuses specifically on the induction and production of the type B sesquiterpenoid trichothecene mycotoxins. Methods are described which permit in liquid culture the small or large scale production and detection of deoxynivalenol (DON) and its various acetylated derivatives. A wheat (Triticum aestivum L.) ear inoculation assay is also explained which allows the direct comparison of mycotoxin production by species, chemotypes and strains with different growth rates and/or disease-causing abilities. Each of these methods is robust and can be used for either detailed time-course studies or end-point analyses. Various analytical methods are available to quantify the levels of DON, 3A-DON and 15A-DON. Some criteria to be considered when making selections between the different analytical methods available are briefly discussed.

  14. Web Analytics: A Picture of the Academic Library Web Site User

    ERIC Educational Resources Information Center

    Black, Elizabeth L.

    2009-01-01

    This article describes the usefulness of Web analytics for understanding the users of an academic library Web site. Using a case study, the analysis describes how Web analytics can answer questions about Web site user behavior, including when visitors come, the duration of the visit, how they get there, the technology they use, and the most…

  15. Analytical Chemistry Laboratory. Progress report for FY 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Boparai, A.S.; Bowers, D.L.

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year (FY) 1996. This annual report is the thirteenth for the ACL. It describes effort on continuing and new projects and contributions of the ACL staff to various programs at ANL. The ACL operates in the ANL system as a full-cost-recovery service center, but has a mission that includes a complementary research and development component: The Analytical Chemistry Laboratory will provide high-quality, cost-effective chemical analysis and related technical support to solve research problems of our clients --more » Argonne National Laboratory, the Department of Energy, and others -- and will conduct world-class research and development in analytical chemistry and its applications. Because of the diversity of research and development work at ANL, the ACL handles a wide range of analytical chemistry problems. Some routine or standard analyses are done, but the ACL usually works with commercial laboratories if our clients require high-volume, production-type analyses. It is common for ANL programs to generate unique problems that require significant development of methods and adaption of techniques to obtain useful analytical data. Thus, much of the support work done by the ACL is very similar to our applied analytical chemistry research.« less

  16. A new method for flight test determination of propulsive efficiency and drag coefficient

    NASA Technical Reports Server (NTRS)

    Bull, G.; Bridges, P. D.

    1983-01-01

    A flight test method is described from which propulsive efficiency as well as parasite and induced drag coefficients can be directly determined using relatively simple instrumentation and analysis techniques. The method uses information contained in the transient response in airspeed for a small power change in level flight in addition to the usual measurement of power required for level flight. Measurements of pitch angle and longitudinal and normal acceleration are eliminated. The theoretical basis for the method, the analytical techniques used, and the results of application of the method to flight test data are presented.

  17. Analyte-driven switching of DNA charge transport: de novo creation of electronic sensors for an early lung cancer biomarker.

    PubMed

    Thomas, Jason M; Chakraborty, Banani; Sen, Dipankar; Yu, Hua-Zhong

    2012-08-22

    A general approach is described for the de novo design and construction of aptamer-based electrochemical biosensors, for potentially any analyte of interest (ranging from small ligands to biological macromolecules). As a demonstration of the approach, we report the rapid development of a made-to-order electronic sensor for a newly reported early biomarker for lung cancer (CTAP III/NAP2). The steps include the in vitro selection and characterization of DNA aptamer sequences, design and biochemical testing of wholly DNA sensor constructs, and translation to a functional electrode-bound sensor format. The working principle of this distinct class of electronic biosensors is the enhancement of DNA-mediated charge transport in response to analyte binding. We first verify such analyte-responsive charge transport switching in solution, using biochemical methods; successful sensor variants were then immobilized on gold electrodes. We show that using these sensor-modified electrodes, CTAP III/NAP2 can be detected with both high specificity and sensitivity (K(d) ~1 nM) through a direct electrochemical reading. To investigate the underlying basis of analyte binding-induced conductivity switching, we carried out Förster Resonance Energy Transfer (FRET) experiments. The FRET data establish that analyte binding-induced conductivity switching in these sensors results from very subtle structural/conformational changes, rather than large scale, global folding events. The implications of this finding are discussed with respect to possible charge transport switching mechanisms in electrode-bound sensors. Overall, the approach we describe here represents a unique design principle for aptamer-based electrochemical sensors; its application should enable rapid, on-demand access to a class of portable biosensors that offer robust, inexpensive, and operationally simplified alternatives to conventional antibody-based immunoassays.

  18. Recent Trends in Analytical Methods to Determine New Psychoactive Substances in Hair

    PubMed Central

    Kyriakou, Chrystalla; Pellegrini, Manuela; García-Algar, Oscar; Marinelli, Enrico; Zaami, Simona

    2017-01-01

    New Psychoactive Substances (NPS) belong to several chemical classes, including phenethylamines, piperazines, synthetic cathinones and synthetic cannabinoids. Development and validation of analytical methods for the determination of NPS both in traditional and alternative matrices is of crucial importance to study drug metabolism and to associate consumption to clinical outcomes and eventual intoxication symptoms. Among different biological matrices, hair is the one with the widest time window to investigate drug-related history and demonstrate past intake. The aim of this paper was to overview the trends of the rapidly evolving analytical methods for the determination of NPS in hair and the usefulness of these methods when applied to real cases. A number of rapid and sensitive methods for the determination of NPS in hair matrix has been recently published, most of them using liquid chromatography coupled to mass spectrometry. Hair digestion and subsequent solid phase extraction or liquid-liquid extraction were described as well as extraction in organic solvents. For most of the methods limits of quantification at picogram per milligram hair were obtained. The measured concentrations for most of the NPS in real samples were in the range of picograms of drug per milligram of hair. Interpretation of the results and lack of cut-off values for the discrimination between chronic consumption and occasional use or external contamination are still challenging. Methods for the determination of NPS in hair are continually emerging to include as many NPS as possible due to the great demand for their detection. PMID:27834146

  19. [Spectral scatter correction of coal samples based on quasi-linear local weighted method].

    PubMed

    Lei, Meng; Li, Ming; Ma, Xiao-Ping; Miao, Yan-Zi; Wang, Jian-Sheng

    2014-07-01

    The present paper puts forth a new spectral correction method based on quasi-linear expression and local weighted function. The first stage of the method is to search 3 quasi-linear expressions to replace the original linear expression in MSC method, such as quadratic, cubic and growth curve expression. Then the local weighted function is constructed by introducing 4 kernel functions, such as Gaussian, Epanechnikov, Biweight and Triweight kernel function. After adding the function in the basic estimation equation, the dependency between the original and ideal spectra is described more accurately and meticulously at each wavelength point. Furthermore, two analytical models were established respectively based on PLS and PCA-BP neural network method, which can be used for estimating the accuracy of corrected spectra. At last, the optimal correction mode was determined by the analytical results with different combination of quasi-linear expression and local weighted function. The spectra of the same coal sample have different noise ratios while the coal sample was prepared under different particle sizes. To validate the effectiveness of this method, the experiment analyzed the correction results of 3 spectral data sets with the particle sizes of 0.2, 1 and 3 mm. The results show that the proposed method can eliminate the scattering influence, and also can enhance the information of spectral peaks. This paper proves a more efficient way to enhance the correlation between corrected spectra and coal qualities significantly, and improve the accuracy and stability of the analytical model substantially.

  20. Investigation of Solitary wave solutions for Vakhnenko-Parkes equation via exp-function and Exp(-ϕ(ξ))-expansion method.

    PubMed

    Roshid, Harun-Or; Kabir, Md Rashed; Bhowmik, Rajandra Chadra; Datta, Bimal Kumar

    2014-01-01

    In this paper, we have described two dreadfully important methods to solve nonlinear partial differential equations which are known as exp-function and the exp(-ϕ(ξ)) -expansion method. Recently, there are several methods to use for finding analytical solutions of the nonlinear partial differential equations. The methods are diverse and useful for solving the nonlinear evolution equations. With the help of these methods, we are investigated the exact travelling wave solutions of the Vakhnenko- Parkes equation. The obtaining soliton solutions of this equation are described many physical phenomena for weakly nonlinear surface and internal waves in a rotating ocean. Further, three-dimensional plots of the solutions such as solitons, singular solitons, bell type solitary wave i.e. non-topological solitons solutions and periodic solutions are also given to visualize the dynamics of the equation.

  1. Current Technical Approaches for the Early Detection of Foodborne Pathogens: Challenges and Opportunities.

    PubMed

    Cho, Il-Hoon; Ku, Seockmo

    2017-09-30

    The development of novel and high-tech solutions for rapid, accurate, and non-laborious microbial detection methods is imperative to improve the global food supply. Such solutions have begun to address the need for microbial detection that is faster and more sensitive than existing methodologies (e.g., classic culture enrichment methods). Multiple reviews report the technical functions and structures of conventional microbial detection tools. These tools, used to detect pathogens in food and food homogenates, were designed via qualitative analysis methods. The inherent disadvantage of these analytical methods is the necessity for specimen preparation, which is a time-consuming process. While some literature describes the challenges and opportunities to overcome the technical issues related to food industry legal guidelines, there is a lack of reviews of the current trials to overcome technological limitations related to sample preparation and microbial detection via nano and micro technologies. In this review, we primarily explore current analytical technologies, including metallic and magnetic nanomaterials, optics, electrochemistry, and spectroscopy. These techniques rely on the early detection of pathogens via enhanced analytical sensitivity and specificity. In order to introduce the potential combination and comparative analysis of various advanced methods, we also reference a novel sample preparation protocol that uses microbial concentration and recovery technologies. This technology has the potential to expedite the pre-enrichment step that precedes the detection process.

  2. Title: Experimental and analytical study of frictional anisotropy of nanotubes

    NASA Astrophysics Data System (ADS)

    Riedo, Elisa; Gao, Yang; Li, Tai-De; Chiu, Hsiang-Chih; Kim, Suenne; Klinke, Christian; Tosatti, Erio

    The frictional properties of Carbon and Boron Nitride nanotubes (NTs) are very important in a variety of applications, including composite materials, carbon fibers, and micro/nano-electromechanical systems. Atomic force microscopy (AFM) is a powerful tool to investigate with nanoscale resolution the frictional properties of individual NTs. Here, we report on an experimental study of the frictional properties of different types of supported nanotubes by AFM. We also propose a quantitative model to describe and then predict the frictional properties of nanotubes sliding on a substrate along (longitudinal friction) or perpendicular (transverse friction) their axis. This model provides a simple but general analytical relationship that well describes the acquired experimental data. As an example of potential applications, this experimental method combined with the proposed model can guide to design better NTs-ceramic composites, or to self-assemble the nanotubes on a surface in a given direction. M. Lucas et al., Nature Materials 8, 876-881 (2009).

  3. Modeling of classical swirl injector dynamics

    NASA Astrophysics Data System (ADS)

    Ismailov, Maksud M.

    The knowledge of the dynamics of a swirl injector is crucial in designing a stable liquid rocket engine. Since the swirl injector is a complex fluid flow device in itself, not much work has been conducted to describe its dynamics either analytically or by using computational fluid dynamics techniques. Even the experimental observation is limited up to date. Thus far, there exists an analytical linear theory by Bazarov [1], which is based on long-wave disturbances traveling on the free surface of the injector core. This theory does not account for variation of the nozzle reflection coefficient as a function of disturbance frequency, and yields a response function which is strongly dependent on the so called artificial viscosity factor. This causes an uncertainty in designing an injector for the given operational combustion instability frequencies in the rocket engine. In this work, the author has studied alternative techniques to describe the swirl injector response, both analytically and computationally. In the analytical part, by using the linear small perturbation analysis, the entire phenomenon of unsteady flow in swirl injectors is dissected into fundamental components, which are the phenomena of disturbance wave refraction and reflection, and vortex chamber resonance. This reveals the nature of flow instability and the driving factors leading to maximum injector response. In the computational part, by employing the nonlinear boundary element method (BEM), the author sets the boundary conditions such that they closely simulate those in the analytical part. The simulation results then show distinct peak responses at frequencies that are coincident with those resonant frequencies predicted in the analytical part. Moreover, a cold flow test of the injector related to this study also shows a clear growth of instability with its maximum amplitude at the first fundamental frequency predicted both by analytical methods and BEM. It shall be noted however that Bazarov's theory does not predict the resonant peaks. Overall this methodology provides clearer understanding of the injector dynamics compared to Bazarov's. Even though the exact value of response is not possible to obtain at this stage of theoretical, computational, and experimental investigation, this methodology sets the starting point from where the theoretical description of reflection/refraction, resonance, and their interaction between each other may be refined to higher order to obtain its more precise value.

  4. Technosocial Predictive Analytics in Support of Naturalistic Decision Making

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanfilippo, Antonio P.; Cowell, Andrew J.; Malone, Elizabeth L.

    2009-06-23

    A main challenge we face in fostering sustainable growth is to anticipate outcomes through predictive and proactive across domains as diverse as energy, security, the environment, health and finance in order to maximize opportunities, influence outcomes and counter adversities. The goal of this paper is to present new methods for anticipatory analytical thinking which address this challenge through the development of a multi-perspective approach to predictive modeling as a core to a creative decision making process. This approach is uniquely multidisciplinary in that it strives to create decision advantage through the integration of human and physical models, and leverages knowledgemore » management and visual analytics to support creative thinking by facilitating the achievement of interoperable knowledge inputs and enhancing the user’s cognitive access. We describe a prototype system which implements this approach and exemplify its functionality with reference to a use case in which predictive modeling is paired with analytic gaming to support collaborative decision-making in the domain of agricultural land management.« less

  5. Diosgenin: Recent Highlights on Pharmacology and Analytical Methodology.

    PubMed

    Jesus, Mafalda; Martins, Ana P J; Gallardo, Eugenia; Silvestre, Samuel

    2016-01-01

    Diosgenin, a steroidal sapogenin, occurs abundantly in plants such as Dioscorea alata , Smilax China, and Trigonella foenum graecum . This bioactive phytochemical not only is used as an important starting material for the preparation of several steroidal drugs in the pharmaceutical industry, but has revealed also high potential and interest in the treatment of various types of disorders such as cancer, hypercholesterolemia, inflammation, and several types of infections. Due to its pharmacological and industrial importance, several extraction and analytical procedures have been developed and applied over the years to isolate, detect, and quantify diosgenin, not only in its natural sources and pharmaceutical compositions, but also in animal matrices for pharmacodynamic, pharmacokinetic, and toxicological studies. Within these, HPLC technique coupled to different detectors is the most commonly analytical procedure described for this compound. However, other alternative methods were also published. Thus, the present review aims to provide collective information on the most recent pharmacological data on diosgenin and on the most relevant analytical techniques used to isolate, detect, and quantify this compound as well.

  6. Diosgenin: Recent Highlights on Pharmacology and Analytical Methodology

    PubMed Central

    2016-01-01

    Diosgenin, a steroidal sapogenin, occurs abundantly in plants such as Dioscorea alata, Smilax China, and Trigonella foenum graecum. This bioactive phytochemical not only is used as an important starting material for the preparation of several steroidal drugs in the pharmaceutical industry, but has revealed also high potential and interest in the treatment of various types of disorders such as cancer, hypercholesterolemia, inflammation, and several types of infections. Due to its pharmacological and industrial importance, several extraction and analytical procedures have been developed and applied over the years to isolate, detect, and quantify diosgenin, not only in its natural sources and pharmaceutical compositions, but also in animal matrices for pharmacodynamic, pharmacokinetic, and toxicological studies. Within these, HPLC technique coupled to different detectors is the most commonly analytical procedure described for this compound. However, other alternative methods were also published. Thus, the present review aims to provide collective information on the most recent pharmacological data on diosgenin and on the most relevant analytical techniques used to isolate, detect, and quantify this compound as well. PMID:28116217

  7. Localized Scale Coupling and New Educational Paradigms in Multiscale Mathematics and Science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingber, Marc; Vorobieff, Peter

    2014-03-14

    We have experimentally demonstrated how microscale phenomena affect suspended particle behavior on the mesoscale, and how particle group behavior on the mesoscale influences the macroscale suspension behavior. Semi-analytical and numerical methods to treat flows on different scales have been developed, and a framework to combine these scale-dependent treatment has been described.

  8. On the design of recursive digital filters

    NASA Technical Reports Server (NTRS)

    Shenoi, K.; Narasimha, M. J.; Peterson, A. M.

    1976-01-01

    A change of variables is described which transforms the problem of designing a recursive digital filter to that of approximation by a ratio of polynomials on a finite interval. Some analytic techniques for the design of low-pass filters are presented, illustrating the use of the transformation. Also considered are methods for the design of phase equalizers.

  9. The Gran Plot Analysis of an Acid Mixture. An Undergraduate Experiment to Highlight this Alternate Method.

    ERIC Educational Resources Information Center

    Boiani, James A.

    1986-01-01

    Describes an experiment which uses the Gran plot for analyzing free ions as well as those involved in an equilibrium. Discusses the benefits of using Gran plots in the study of acids, as well as other analytes in solutions. Presents background theory along with a description of the experimental procedures. (TW)

  10. Approximate analysis of thermal convection in a crystal-growth cell for Spacelab 3

    NASA Technical Reports Server (NTRS)

    Dressler, R. F.

    1982-01-01

    The transient and steady thermal convection in microgravity is described. The approach is applicable to many three dimensional flows in containers of various shapes with various thermal gradients imposed. The method employs known analytical solutions to two dimensional thermal flows in simpler geometries, and does not require recourse to numerical calculations by computer.

  11. The Hazardous-Drums Project: A Multiweek Laboratory Exercise for General Chemistry Involving Environmental, Quality Control, and Cost Evaluation

    ERIC Educational Resources Information Center

    Hayes, David; Widanski, Bozena

    2013-01-01

    A laboratory experiment is described that introduces students to "real-world" hazardous waste management issues chemists face. The students are required to define an analytical problem, choose a laboratory analysis method, investigate cost factors, consider quality-control issues, interpret the meaning of results, and provide management…

  12. The Perioperative Experience of the Ambulatory Surgery Patient

    DTIC Science & Technology

    2000-10-01

    researchers are phenomenology , grounded theory , ethnography , history, case studies , and analytical philosophy (Munhall, 1994). Phenomenology The aim of the...Burns & Grove, 1997). In this study , a phenomenological approach was used. Phenomenology is both a philosophy and a research method . The purpose of... Theories in qualitative research are often described as being grounded in the empirical data

  13. The Motivational Effects of Success or Failure in Urban Elementary School Teaching

    ERIC Educational Resources Information Center

    Waterman, Bradford H.

    2012-01-01

    This study describes teachers' experiences of success and failure in teaching through interviews. The analytical framework for this study was based on Activity Theory (Leon'tev, 1978), and the research methods were developed by Herzberg et al. (1959). The inclusion of factors identified by Seligman (2006) and Maslach (1982) allowed for…

  14. Final Technical Report: Collaborative Research Center for Nonlinear Simulation of Energetic Particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berk, Herbert L.

    2018-02-15

    The study of this project focused on developing a reduced nonlinear model to describe chirping processes in a fusion plasma. A successful method was developed with results clear enough to allow an analytic theory to be developed that replicates the long term response of a nonlinear phase space structure immersed in the MHD continnuum.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Heinrich, R.R.; Jensen, K.J.

    Technical and administrative activities of the Analytical Chemistry Laboratory (ACL) are reported for fiscal year 1984. The ACL is a full-cost-recovery service center, with the primary mission of providing a broad range of technical support services to the scientific and engineering programs at ANL. In addition, ACL conducts a research program in analytical chemistry, works on instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL is administratively within the Chemical Technology Division, the principal user, but provides technical support for all of the technical divisions and programs at ANL. The ACL has threemore » technical groups - Chemical Analysis, Instrumental Analysis, and Organic Analysis. Under technical activities 26 projects are briefly described. Under professional activities, a list is presented for publications and reports, oral presentations, awards and meetings attended. 6 figs., 2 tabs.« less

  16. Selective pressurized liquid extraction of replacement and legacy brominated flame retardants from soil.

    PubMed

    McGrath, Thomas J; Morrison, Paul D; Ball, Andrew S; Clarke, Bradley O

    2016-08-05

    Polybrominated diphenyl ethers (PBDEs) are a class of flame retardant registered as UN POPs due to their persistence in the environment, bioaccumulation potential and toxicity. Replacement novel brominated flame retardants (NBFRs) have exhibited similar health hazards and environmental distribution, becoming recognized as significant contaminants. This work describes the development and validation of a sensitive and reliable method for the simultaneous quantitation of PBDEs and NBFRs in environmental soil samples using selective pressurized liquid extraction (S-PLE) and gas chromatography coupled to triple quadrupole mass spectrometry (GC-(EI)-MS/MS). Under optimal conditions, extraction of eight PBDEs (-28, -47, -99, -100, -153, -154, -183 and -209) and five NBFRs; pentabromotoluene (PBT), pentabromoethylbenzene (PBEB), hexabromobenzene (HBB), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (EH-TBB) and bis(2,4,6-tribromophenoxy)ethane (BTBPE) was performed at 100°C and 1500psi using a 1:1 mixture of hexane and dichloromethane. The method utilized 33mL capacity PLE cells containing, from bottom to top, a single cellulose filter, 3g activated Florisil, 6g acid silica (10% w/w), 3g Na2SO4, another cellulose filter, 2g activated copper powder and 3g soil sample dispersed in 2g Na2SO4 and 1g of Hydromatrix. The method was evaluated by repeated extraction and analysis of all analytes from 3g soil at three spike concentrations. Good recoveries were observed for most analytes at each of the spiking levels with RSD values generally below 20%. MDLs ranged from 0.01 to 4.8ng/g dw for PBDEs and 0.01-0.55ng/g dw for NBFRs. The described one-step combined extraction and cleanup method reduces sample processing times compared with traditional procedures, while delivering comparable analytical performance. The method was successfully applied to environmental soil samples (n=5), detecting PBDEs in each sample and providing the first account of NBFR contamination in Australian soils. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Evaluation of Analytical Errors in a Clinical Chemistry Laboratory: A 3 Year Experience

    PubMed Central

    Sakyi, AS; Laing, EF; Ephraim, RK; Asibey, OF; Sadique, OK

    2015-01-01

    Background: Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. Aim: We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. Materials and Methods: We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). Results: A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Conclusion: Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified. PMID:25745569

  18. Analytical study of fractional equations describing anomalous diffusion of energetic particles

    NASA Astrophysics Data System (ADS)

    Tawfik, A. M.; Fichtner, H.; Schlickeiser, R.; Elhanbaly, A.

    2017-06-01

    To present the main influence of anomalous diffusion on the energetic particle propagation, the fractional derivative model of transport is developed by deriving the fractional modified Telegraph and Rayleigh equations. Analytical solutions of the fractional modified Telegraph and the fractional Rayleigh equations, which are defined in terms of Caputo fractional derivatives, are obtained by using the Laplace transform and the Mittag-Leffler function method. The solutions of these fractional equations are given in terms of special functions like Fox’s H, Mittag-Leffler, Hermite and Hyper-geometric functions. The predicted travelling pulse solutions are discussed in each case for different values of fractional order.

  19. Analytic descriptions of cylindrical electromagnetic waves in a nonlinear medium

    PubMed Central

    Xiong, Hao; Si, Liu-Gang; Yang, Xiaoxue; Wu, Ying

    2015-01-01

    A simple but highly efficient approach for dealing with the problem of cylindrical electromagnetic waves propagation in a nonlinear medium is proposed based on an exact solution proposed recently. We derive an analytical explicit formula, which exhibiting rich interesting nonlinear effects, to describe the propagation of any amount of cylindrical electromagnetic waves in a nonlinear medium. The results obtained by using the present method are accurately concordant with the results of using traditional coupled-wave equations. As an example of application, we discuss how a third wave affects the sum- and difference-frequency generation of two waves propagation in the nonlinear medium. PMID:26073066

  20. Ab initio simulation of diffractometer instrumental function for high-resolution X-ray diffraction1

    PubMed Central

    Mikhalychev, Alexander; Benediktovitch, Andrei; Ulyanenkova, Tatjana; Ulyanenkov, Alex

    2015-01-01

    Modeling of the X-ray diffractometer instrumental function for a given optics configuration is important both for planning experiments and for the analysis of measured data. A fast and universal method for instrumental function simulation, suitable for fully automated computer realization and describing both coplanar and noncoplanar measurement geometries for any combination of X-ray optical elements, is proposed. The method can be identified as semi-analytical backward ray tracing and is based on the calculation of a detected signal as an integral of X-ray intensities for all the rays reaching the detector. The high speed of calculation is provided by the expressions for analytical integration over the spatial coordinates that describe the detection point. Consideration of the three-dimensional propagation of rays without restriction to the diffraction plane provides the applicability of the method for noncoplanar geometry and the accuracy for characterization of the signal from a two-dimensional detector. The correctness of the simulation algorithm is checked in the following two ways: by verifying the consistency of the calculated data with the patterns expected for certain simple limiting cases and by comparing measured reciprocal-space maps with the corresponding maps simulated by the proposed method for the same diffractometer configurations. Both kinds of tests demonstrate the agreement of the simulated instrumental function shape with the measured data. PMID:26089760

Top