TEST METHODS TO DETERMINE THE MERCURY EMISSIONS FROM SLUDGE INCINERATION PLANTS
Two test methods for mercury are described along with the laboratory and field studies done in developing and validating them. One method describes how to homogenize and analyze large quantities of sewage sludge. The other test method describes how to measure the mercury emission...
Test Methods for Robot Agility in Manufacturing.
Downs, Anthony; Harrison, William; Schlenoff, Craig
2016-01-01
The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.
Test Methods for Robot Agility in Manufacturing
Downs, Anthony; Harrison, William; Schlenoff, Craig
2017-01-01
Purpose The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. Design/methodology/approach The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. Findings The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. Practical Implications The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. Originality / value The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots. PMID:28203034
NASA Technical Reports Server (NTRS)
Hartill, W. R.
1977-01-01
A hypersonic wind tunnel test method for obtaining credible aerodynamic data on a complete hypersonic vehicle (generic X-24c) with scramjet exhaust flow simulation is described. The general problems of simulating the scramjet exhaust as well as accounting for scramjet inlet flow and vehicle forces are analyzed, and candidate test methods are described and compared. The method selected as most useful makes use of a thrust-minus-drag flow-through balance with a completely metric model. Inlet flow is diverted by a fairing. The incremental effect of the fairing is determined in the testing of two reference models. The net thrust of the scramjet module is an input to be determined in large-scale module tests with scramjet combustion. Force accounting is described, and examples of force component levels are predicted. Compatibility of the test method with candidate wind tunnel facilities is described, and a preliminary model mechanical arrangement drawing is presented. The balance design and performance requirements are described in a detailed specification. Calibration procedures, model instrumentation, and a test plan for the model are outlined.
NASA Technical Reports Server (NTRS)
Silsbee, F B; Loeb, L B; Sawyer, L G; Fonseca, E L; Dickinson, H C; Agnew, P G
1920-01-01
The successful operation of the spark plug depends to a large extent on the gas tightness of the plug. Part 1 of this report describes the method used for measuring the gas tightness of aviation spark plugs. Part 2 describes the methods used in testing the electrical conductivity of the insulation material when hot. Part 3 describes the testing of the cold dielectric strength of the insulation material, the resistance to mechanical shock, and the final engine test.
Aeronautic Instruments. Section V : Power Plant Instruments
NASA Technical Reports Server (NTRS)
Washburn, G E; Sylvander, R C; Mueller, E F; Wilhelm, R M; Eaton, H N; Warner, John A C
1923-01-01
Part 1 gives a general discussion of the uses, principles, construction, and operation of airplane tachometers. Detailed description of all available instruments, both foreign and domestic, are given. Part 2 describes methods of tests and effect of various conditions encountered in airplane flight such as change of temperature, vibration, tilting, and reduced air pressure. Part 3 describes the principal types of distance reading thermometers for aircraft engines, including an explanation of the physical principles involved in the functioning of the instruments and proper filling of the bulbs. Performance requirements and testing methods are given and a discussion of the source of error and results of tests. Part 4 gives methods of tests and calibration, also requirements of gauges of this type for the pressure measurement of the air pressure in gasoline tanks and the engine oil pressure on airplanes. Part 5 describes two types of gasoline gauges, the float type and the pressure type. Methods of testing and calibrating gasoline depth gauges are given. The Schroeder, R. A. E., and the Mark II flowmeters are described.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Measurement environments and testing
NASA Astrophysics Data System (ADS)
Marvin, A. C.
1991-06-01
The various methods used to assess both the emission (interference generation) performance of electronic equipment and the immunity of electronic equipment to external electromagnetic interference are described. The measurement methods attempt to simulate realistic operating conditions for the equipment being tested, yet at the same time they must be repeatable and practical to operate. This has led to the development of a variety of test methods, each of which has its limitations. Concentration is on the most common measurement methods such as open-field test sites, screened enclosures and transverse electromagnetic (TEM) cells. The physical justification for the methods, their limitations, and measurement precision are described. Ways of relating similar measurements made by different methods are discussed, and some thoughts on future measurement improvements are presented.
Seminar on Understanding Digital Control and Analysis in Vibration Test Systems
NASA Technical Reports Server (NTRS)
1975-01-01
The advantages of the digital methods over the analog vibration methods are demonstrated. The following topics are covered: (1) methods of computer-controlled random vibration and reverberation acoustic testing, (2) methods of computer-controlled sinewave vibration testing, and (3) methods of computer-controlled shock testing. General algorithms are described in the form of block diagrams and flow diagrams.
2017-06-16
Acoustic Impacts on Marine Mammals and Sea Turtles: Methods and Analytical Approach for Phase III Training and Testing Sarah A. Blackstock Joseph O...December 2017 4. TITLE AND SUBTITLE Quantifying Acoustic Impacts on Marine Mammals and Sea Turtles: Methods and Analytical Approach for Phase III...Navy’s Phase III Study Areas as described in each Environmental Impact Statement/ Overseas Environmental Impact Statement and describes the methods
Altitude Chamber Testing of the Passenger Oxygen System (POS)
2009-08-01
4 5.0 Schedule 4 6.0 Method for Unmanned Testing 4 7.0 Unmanned Testing Results 6 8.0 Methods for Manned...manned testing. 30 Mar 09: Subjects received orientation and training briefings. 31 Mar-03 Apr 09: POS manned testing conducted. 6.0 Method ...8.0 Methods for Manned Testing: The system was tested in five manned modes. The details of each mode are described in Appendix B (ICD for
Antimicrobial Testing Methods & Procedures: MB-03-07
This protocol describes the procedures for the preparation of carriers for the following methods: the AOAC UDM, AOAC Tuberculocidal Activity of Disinfectants Test, AOAC GSPT, the Disinfectant Towelette Test, and the AOAC SAT.
Screening tests for hazard classification of complex waste materials - Selection of methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weltens, R., E-mail: reinhilde.weltens@vito.be; Vanermen, G.; Tirez, K.
In this study we describe the development of an alternative methodology for hazard characterization of waste materials. Such an alternative methodology for hazard assessment of complex waste materials is urgently needed, because the lack of a validated instrument leads to arbitrary hazard classification of such complex waste materials. False classification can lead to human and environmental health risks and also has important financial consequences for the waste owner. The Hazardous Waste Directive (HWD) describes the methodology for hazard classification of waste materials. For mirror entries the HWD classification is based upon the hazardous properties (H1-15) of the waste which canmore » be assessed from the hazardous properties of individual identified waste compounds or - if not all compounds are identified - from test results of hazard assessment tests performed on the waste material itself. For the latter the HWD recommends toxicity tests that were initially designed for risk assessment of chemicals in consumer products (pharmaceuticals, cosmetics, biocides, food, etc.). These tests (often using mammals) are not designed nor suitable for the hazard characterization of waste materials. With the present study we want to contribute to the development of an alternative and transparent test strategy for hazard assessment of complex wastes that is in line with the HWD principles for waste classification. It is necessary to cope with this important shortcoming in hazardous waste classification and to demonstrate that alternative methods are available that can be used for hazard assessment of waste materials. Next, by describing the pros and cons of the available methods, and by identifying the needs for additional or further development of test methods, we hope to stimulate research efforts and development in this direction. In this paper we describe promising techniques and argument on the test selection for the pilot study that we have performed on different types of waste materials. Test results are presented in a second paper. As the application of many of the proposed test methods is new in the field of waste management, the principles of the tests are described. The selected tests tackle important hazardous properties but refinement of the test battery is needed to fulfil the a priori conditions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Yong Joon; Yoo, Jun Soo; Smith, Curtis Lee
2015-09-01
This INL plan comprehensively describes the Requirements Traceability Matrix (RTM) on main physics and numerical method of the RELAP-7. The plan also describes the testing-based software verification and validation (SV&V) process—a set of specially designed software models used to test RELAP-7.
NASA Technical Reports Server (NTRS)
Keegan, W. B.
1974-01-01
In order to produce cost effective environmental test programs, the test specifications must be realistic and to be useful, they must be available early in the life of a program. This paper describes a method for achieving such specifications for subsystems by utilizing the results of a statistical analysis of data acquired at subsystem mounting locations during system level environmental tests. The paper describes the details of this statistical analysis. The resultant recommended levels are a function of the subsystems' mounting location in the spacecraft. Methods of determining this mounting 'zone' are described. Recommendations are then made as to which of the various problem areas encountered should be pursued further.
40 CFR 63.786 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.786...) National Emission Standards for Shipbuilding and Ship Repair (Surface Coating) § 63.786 Test methods and procedures. (a) For the compliance procedures described in § 63.785(c) (1) through (c)(3), Method 24 of 40...
The Psychology Experiment Building Language (PEBL) and PEBL Test Battery
Mueller, Shane T.; Piper, Brian J.
2014-01-01
Background We briefly describe the Psychology Experiment Building Language (PEBL), an open source software system for designing and running psychological experiments. New Method We describe the PEBL test battery, a set of approximately 70 behavioral tests which can be freely used, shared, and modified. Included is a comprehensive set of past research upon which tests in the battery are based. Results We report the results of benchmark tests that establish the timing precision of PEBL. Comparison with Existing Method We consider alternatives to the PEBL system and battery tests. Conclusions We conclude with a discussion of the ethical factors involved in the open source testing movement. PMID:24269254
Detection of Test Collusion via Kullback-Leibler Divergence
ERIC Educational Resources Information Center
Belov, Dmitry I.
2013-01-01
The development of statistical methods for detecting test collusion is a new research direction in the area of test security. Test collusion may be described as large-scale sharing of test materials, including answers to test items. Current methods of detecting test collusion are based on statistics also used in answer-copying detection.…
ERIC Educational Resources Information Center
Frein, Scott T.
2011-01-01
This article describes three experiments comparing paper-and-pencil tests (PPTs) to computer-based tests (CBTs) in terms of test method preferences and student performance. In Experiment 1, students took tests using three methods: PPT in class, CBT in class, and CBT at the time and place of their choosing. Results indicate that test method did not…
Validated Test Method 5030C: Purge-and-Trap for Aqueous Samples
This method describes a purge-and-trap procedure for the analysis of volatile organic compoundsin aqueous samples & water miscible liquid samples. It also describes the analysis of high concentration soil and waste sample extracts prepared in Method 5035.
Measurement, testing, and safety technology: A compilation
NASA Technical Reports Server (NTRS)
1974-01-01
Methods and techniques in the related areas of measurement, testing, and safety are presented. Measuring techniques and devices and testing methods and devices are described. Articles on equipment modifications or procedures are included. Patent information is presented.
Clinical experimental stress studies: methods and assessment.
Bali, Anjana; Jaggi, Amteshwar Singh
2015-01-01
Stress is a state of threatened homeostasis during which a variety of adaptive processes are activated to produce physiological and behavioral changes. Stress induction methods are pivotal for understanding these physiological or pathophysiological changes in the body in response to stress. Furthermore, these methods are also important for the development of novel pharmacological agents for stress management. The well-described methods to induce stress in humans include the cold pressor test, Trier Social Stress Test, Montreal Imaging Stress Task, Maastricht Acute Stress Test, CO2 challenge test, Stroop test, Paced Auditory Serial Addition Task, noise stress, and Mannheim Multicomponent Stress Test. Stress assessment in humans is done by measuring biochemical markers such as cortisol, cortisol awakening response, dexamethasone suppression test, salivary α-amylase, plasma/urinary norepinephrine, norepinephrine spillover rate, and interleukins. Physiological and behavioral changes such as galvanic skin response, heart rate variability, pupil size, and muscle and/or skin sympathetic nerve activity (microneurography) and cardiovascular parameters such as heart rate, blood pressure, and self-reported anxiety are also monitored to assess stress response. This present review describes these commonly employed methods to induce stress in humans along with stress assessment methods.
Validity evidence based on test content.
Sireci, Stephen; Faulkner-Bond, Molly
2014-01-01
Validity evidence based on test content is one of the five forms of validity evidence stipulated in the Standards for Educational and Psychological Testing developed by the American Educational Research Association, American Psychological Association, and National Council on Measurement in Education. In this paper, we describe the logic and theory underlying such evidence and describe traditional and modern methods for gathering and analyzing content validity data. A comprehensive review of the literature and of the aforementioned Standards is presented. For educational tests and other assessments targeting knowledge and skill possessed by examinees, validity evidence based on test content is necessary for building a validity argument to support the use of a test for a particular purpose. By following the methods described in this article, practitioners have a wide arsenal of tools available for determining how well the content of an assessment is congruent with and appropriate for the specific testing purposes.
40 CFR 264.314 - Special requirements for bulk and containerized liquids.
Code of Federal Regulations, 2010 CFR
2010-07-01
... containerized liquids. 264.314 Section 264.314 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... test must be used: Method 9095B (Paint Filter Liquids Test) as described in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in...
The report describes the development and evaluation of a large chamber test method for measuring emissions from dry-process photocopiers. The test method was developed in two phases. Phase 1 was a single-laboratory evaluation at Research Triangle Institute (RTI) using four, mid-r...
The user's guide describes the methods used by TEST to predict toxicity and physical properties (including the new mode of action based method used to predict acute aquatic toxicity). It describes all of the experimental data sets included in the tool. It gives the prediction res...
Method for Smoke Spread Testing of Large Premises
NASA Astrophysics Data System (ADS)
Walmerdahl, P.; Werling, P.
2001-11-01
A method for performing non-destructive smoke spread tests has been developed, tested and applied to several existing buildings. Burning methanol in different size steel trays cooled by water generates the heat source. Several tray sizes are available to cover fire sources up to nearly 1MW. The smoke is supplied by means of a suitable number of smoke generators that produce a smoke, which can be described as a non-toxic aerosol. The advantage of the method is that it provides a means for performing non-destructive tests in already existing buildings and other installations for the purpose of evaluating the functionality and design of the active fire protection measures such as smoke extraction systems, etc. In the report, the method is described in detail and experimental data from the try-out of the method are also presented in addition to a discussion on applicability and flexibility of the method.
NASA Technical Reports Server (NTRS)
Bond, Thomas H. (Technical Monitor); Anderson, David N.
2004-01-01
This manual reviews the derivation of the similitude relationships believed to be important to ice accretion and examines ice-accretion data to evaluate their importance. Both size scaling and test-condition scaling methods employing the resulting similarity parameters are described, and experimental icing tests performed to evaluate scaling methods are reviewed with results. The material included applies primarily to unprotected, unswept geometries, but some discussion of how to approach other situations is included as well. The studies given here and scaling methods considered are applicable only to Appendix-C icing conditions. Nearly all of the experimental results presented have been obtained in sea-level tunnels. Recommendations are given regarding which scaling methods to use for both size scaling and test-condition scaling, and icing test results are described to support those recommendations. Facility limitations and size-scaling restrictions are discussed. Finally, appendices summarize the air, water and ice properties used in NASA scaling studies, give expressions for each of the similarity parameters used and provide sample calculations for the size-scaling and test-condition scaling methods advocated.
Testing methods and techniques: Strength of materials and components. A compilation
NASA Technical Reports Server (NTRS)
1971-01-01
The methods, techniques, and devices used in testing the mechanical properties of various materials are presented. Although metals and metal alloys are featured prominently, some of the items describe tests on a variety of other materials, from concrete to plastics. Many of the tests described are modifications of standard testing procedures, intended either to adapt them to different materials and conditions, or to make them more rapid and accurate. In either case, the approaches presented can result in considerable cost savings and improved quality control. The compilation is presented in two sections. The first deals specifically with material strength testing; the second treats the special category of fracture and fatigue testing.
Agin, Patricia Poh; Edmonds, Susan H
2002-08-01
The goals of this study were (i) to demonstrate that existing and widely used sun protection factor (SPF) test methodologies can produce accurate and reproducible results for high SPF formulations and (ii) to provide data on the number of test-subjects needed, the variability of the data, and the appropriate exposure increments needed for testing high SPF formulations. Three high SPF formulations were tested, according to the Food and Drug Administration's (FDA) 1993 tentative final monograph (TFM) 'very water resistant' test method and/or the 1978 proposed monograph 'waterproof' test method, within one laboratory. A fourth high SPF formulation was tested at four independent SPF testing laboratories, using the 1978 waterproof SPF test method. All laboratories utilized xenon arc solar simulators. The data illustrate that the testing conducted within one laboratory, following either the 1978 proposed or the 1993 TFM SPF test method, was able to reproducibly determine the SPFs of the formulations tested, using either the statistical analysis method in the proposed monograph or the statistical method described in the TFM. When one formulation was tested at four different laboratories, the anticipated variation in the data owing to the equipment and other operational differences was minimized through the use of the statistical method described in the 1993 monograph. The data illustrate that either the 1978 proposed monograph SPF test method or the 1993 TFM SPF test method can provide accurate and reproducible results for high SPF formulations. Further, these results can be achieved with panels of 20-25 subjects with an acceptable level of variability. Utilization of the statistical controls from the 1993 sunscreen monograph can help to minimize lab-to-lab variability for well-formulated products.
Ice Growth Measurements from Image Data to Support Ice Crystal and Mixed-Phase Accretion Testing
NASA Technical Reports Server (NTRS)
Struk, Peter M.; Lynch, Christopher J.
2012-01-01
This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.
Ice Growth Measurements from Image Data to Support Ice-Crystal and Mixed-Phase Accretion Testing
NASA Technical Reports Server (NTRS)
Struk, Peter, M; Lynch, Christopher, J.
2012-01-01
This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-16
...: EPA Method Development Update on Drinking Water Testing Methods for Contaminant Candidate List... Division will describe methods currently in development for many CCL contaminants, with an expectation that several of these methods will support future cycles of the Unregulated Contaminant Monitoring Rule (UCMR...
Simple Flame Test Techniques Using Cotton Swabs
ERIC Educational Resources Information Center
Sanger, Michael J.; Phelps, Amy J.; Banks, Catherine
2004-01-01
Three alternative methods for performing flame tests using cheaply and easily available cotton swabs are described. These flame tests are useful for chemical demonstrations or laboratory experiments because they are quick and easy to perform with easy cleanup and disposal methods.
SPSS and SAS programs for comparing Pearson correlations and OLS regression coefficients.
Weaver, Bruce; Wuensch, Karl L
2013-09-01
Several procedures that use summary data to test hypotheses about Pearson correlations and ordinary least squares regression coefficients have been described in various books and articles. To our knowledge, however, no single resource describes all of the most common tests. Furthermore, many of these tests have not yet been implemented in popular statistical software packages such as SPSS and SAS. In this article, we describe all of the most common tests and provide SPSS and SAS programs to perform them. When they are applicable, our code also computes 100 × (1 - α)% confidence intervals corresponding to the tests. For testing hypotheses about independent regression coefficients, we demonstrate one method that uses summary data and another that uses raw data (i.e., Potthoff analysis). When the raw data are available, the latter method is preferred, because use of summary data entails some loss of precision due to rounding.
ERIC Educational Resources Information Center
Patalino, Marianne
Problems in current course evaluation methods are discussed and an alternative method is described for the construction, analysis, and interpretation of a test to evaluate instructional programs. The method presented represents a different approach to the traditional overreliance on standardized achievement tests and the total scores they provide.…
DOT National Transportation Integrated Search
2008-02-01
The objective of the proposed research project is to compare the results of two recently introduced nondestructive load test methods to the existing 24-hour load test method described in Chapter 20 of ACI 318-05. The two new methods of nondestructive...
[Visualisation methods for etheric formative forces].
Burkhard, B; Kittel, R
2009-09-01
Rudolf Steiner, the founder of anthroposophy, suggested the development of visualisation methods for "etheric formative forces". The essential methods, their "spiritual scientific" basis and indications are described and their claims critically tested. The methods are not validated, the key criteria for diagnostic tests (reproducibility, sensitivity, specifity) are not given.
Antimicrobial Testing Methods & Procedures: MB-09-06
Describes the methodology used to determine the efficacy of towelette-based disinfectants against microbes on hard surfaces. The test is based on AOAC Method 961.02 (Germicidal Spray Products as Disinfectants).
Evaluation of optical connectors for consideration in military avionics
NASA Astrophysics Data System (ADS)
Uhlhorn, Brian L.; Drexler, Gregory M.; Nelson, Ryan L.; Stevens, Rick C.
2006-08-01
This paper describes the method used to evaluate single-mode optical connectors under consideration for military avionics platforms. This testing is described in terms of the appropriate fiber optics test procedures (FOTPs) from the TIA/EIA-455 series.
Verification of Ceramic Structures
NASA Astrophysics Data System (ADS)
Behar-Lafenetre, Stephanie; Cornillon, Laurence; Rancurel, Michael; De Graaf, Dennis; Hartmann, Peter; Coe, Graham; Laine, Benoit
2012-07-01
In the framework of the “Mechanical Design and Verification Methodologies for Ceramic Structures” contract [1] awarded by ESA, Thales Alenia Space has investigated literature and practices in affiliated industries to propose a methodological guideline for verification of ceramic spacecraft and instrument structures. It has been written in order to be applicable to most types of ceramic or glass-ceramic materials - typically Cesic®, HBCesic®, Silicon Nitride, Silicon Carbide and ZERODUR®. The proposed guideline describes the activities to be performed at material level in order to cover all the specific aspects of ceramics (Weibull distribution, brittle behaviour, sub-critical crack growth). Elementary tests and their post-processing methods are described, and recommendations for optimization of the test plan are given in order to have a consistent database. The application of this method is shown on an example in a dedicated article [7]. Then the verification activities to be performed at system level are described. This includes classical verification activities based on relevant standard (ECSS Verification [4]), plus specific analytical, testing and inspection features. The analysis methodology takes into account the specific behaviour of ceramic materials, especially the statistical distribution of failures (Weibull) and the method to transfer it from elementary data to a full-scale structure. The demonstration of the efficiency of this method is described in a dedicated article [8]. The verification is completed by classical full-scale testing activities. Indications about proof testing, case of use and implementation are given and specific inspection and protection measures are described. These additional activities are necessary to ensure the required reliability. The aim of the guideline is to describe how to reach the same reliability level as for structures made of more classical materials (metals, composites).
Significance testing of rules in rule-based models of human problem solving
NASA Technical Reports Server (NTRS)
Lewis, C. M.; Hammer, J. M.
1986-01-01
Rule-based models of human problem solving have typically not been tested for statistical significance. Three methods of testing rules - analysis of variance, randomization, and contingency tables - are presented. Advantages and disadvantages of the methods are also described.
Simulation of Nuclear Reactor Kinetics by the Monte Carlo Method
NASA Astrophysics Data System (ADS)
Gomin, E. A.; Davidenko, V. D.; Zinchenko, A. S.; Kharchenko, I. K.
2017-12-01
The KIR computer code intended for calculations of nuclear reactor kinetics using the Monte Carlo method is described. The algorithm implemented in the code is described in detail. Some results of test calculations are given.
ERIC Educational Resources Information Center
Groseclose, Richard
This third in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II explains the principles of magnets and magnetic fields and how they are applied in magnetic particle testing, describes the theory and methods of magnetizing test specimens, describes the test equipment used, discusses the principles and…
Accelerated life testing of spacecraft subsystems
NASA Technical Reports Server (NTRS)
Wiksten, D.; Swanson, J.
1972-01-01
The rationale and requirements for conducting accelerated life tests on electronic subsystems of spacecraft are presented. A method for applying data on the reliability and temperature sensitivity of the parts contained in a sybsystem to the selection of accelerated life test parameters is described. Additional considerations affecting the formulation of test requirements are identified, and practical limitations of accelerated aging are described.
NASA Technical Reports Server (NTRS)
Wright, Sarah E.; Ungar, Eugene K.
2017-01-01
Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the testing that was performed in early and mid-2017. The test article and the temporary thermocouple attachment methods tested are described. During the first test, fully half of the thermocouples detached - although the detachment showed subtly in the data for some. The second test was performed to confirm the data from the first test and to investigate the effect of test article and thermocouple grounding. The results of the testing over temperatures ranging from -150 to 200degF are detailed and preliminary recommendations are made for temporary thermocouple attachment methods.
Antenna testing for the Inmarsat 2 ground control system
NASA Astrophysics Data System (ADS)
Ashton, C.
1992-02-01
This article describes how the antennas of the Inmarsat 2 TT&C and IOT ground stations were tested and calibrated. It explains the main test methods used, giving the theory behind the tests and indicates some of the practical difficulties encountered during testing. Techniques described include the use of radio stars, boresight antennas and satellite verification testing using Intelsat and Inmarsat satellites. Parameters tested include gain, G/T (figure of merit), sidelobe patterns, cross polar discrimination and isolation.
The Ins and Outs of DNA Fingerprinting the Infectious Fungi
Soll, David R.
2000-01-01
DNA fingerprinting methods have evolved as major tools in fungal epidemiology. However, no single method has emerged as the method of choice, and some methods perform better than others at different levels of resolution. In this review, requirements for an effective DNA fingerprinting method are proposed and procedures are described for testing the efficacy of a method. In light of the proposed requirements, the most common methods now being used to DNA fingerprint the infectious fungi are described and assessed. These methods include restriction fragment length polymorphisms (RFLP), RFLP with hybridization probes, randomly amplified polymorphic DNA and other PCR-based methods, electrophoretic karyotyping, and sequencing-based methods. Procedures for computing similarity coefficients, generating phylogenetic trees, and testing the stability of clusters are then described. To facilitate the analysis of DNA fingerprinting data, computer-assisted methods are described. Finally, the problems inherent in the collection of test and control isolates are considered, and DNA fingerprinting studies of strain maintenance during persistent or recurrent infections, microevolution in infecting strains, and the origin of nosocomial infections are assessed in light of the preceding discussion of the ins and outs of DNA fingerprinting. The intent of this review is to generate an awareness of the need to verify the efficacy of each DNA fingerprinting method for the level of genetic relatedness necessary to answer the epidemiological question posed, to use quantitative methods to analyze DNA fingerprint data, to use computer-assisted DNA fingerprint analysis systems to analyze data, and to file data in a form that can be used in the future for retrospective and comparative studies. PMID:10756003
Calculating p-values and their significances with the Energy Test for large datasets
NASA Astrophysics Data System (ADS)
Barter, W.; Burr, C.; Parkes, C.
2018-04-01
The energy test method is a multi-dimensional test of whether two samples are consistent with arising from the same underlying population, through the calculation of a single test statistic (called the T-value). The method has recently been used in particle physics to search for samples that differ due to CP violation. The generalised extreme value function has previously been used to describe the distribution of T-values under the null hypothesis that the two samples are drawn from the same underlying population. We show that, in a simple test case, the distribution is not sufficiently well described by the generalised extreme value function. We present a new method, where the distribution of T-values under the null hypothesis when comparing two large samples can be found by scaling the distribution found when comparing small samples drawn from the same population. This method can then be used to quickly calculate the p-values associated with the results of the test.
A 3D front tracking method on a CPU/GPU system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bo, Wurigen; Grove, John
2011-01-21
We describe the method to port a sequential 3D interface tracking code to a GPU with CUDA. The interface is represented as a triangular mesh. Interface geometry properties and point propagation are performed on a GPU. Interface mesh adaptation is performed on a CPU. The convergence of the method is assessed from the test problems with given velocity fields. Performance results show overall speedups from 11 to 14 for the test problems under mesh refinement. We also briefly describe our ongoing work to couple the interface tracking method with a hydro solver.
Application of interactive computer graphics in wind-tunnel dynamic model testing
NASA Technical Reports Server (NTRS)
Doggett, R. V., Jr.; Hammond, C. E.
1975-01-01
The computer-controlled data-acquisition system recently installed for use with a transonic dynamics tunnel was described. This includes a discussion of the hardware/software features of the system. A subcritical response damping technique, called the combined randomdec/moving-block method, for use in windtunnel-model flutter testing, that has been implemented on the data-acquisition system, is described in some detail. Some results using the method are presented and the importance of using interactive graphics in applying the technique in near real time during wind-tunnel test operations is discussed.
Will the "Real" Proficiency Standard Please Stand Up?
ERIC Educational Resources Information Center
Baron, Joan Boykoff; And Others
Connecticut's experience with four different standard-setting methods regarding multiple choice proficiency tests is described. The methods include Angoff, Nedelsky, Borderline Group, and Contrasting Groups Methods. All Connecticut ninth graders were administered proficiency tests in reading, language arts, and mathematics. As soon as final test…
33 CFR 183.53 - Horsepower capacity.
Code of Federal Regulations, 2011 CFR
2011-07-01
... considered because of the potential for exceeding the capabilities of the boat while performing the test... method discussed in paragraph (a) of this section, or for certain qualifying boats, the performance test... qualifying under this paragraph, the performance test method described in this paragraph may be used to...
33 CFR 183.53 - Horsepower capacity.
Code of Federal Regulations, 2014 CFR
2014-07-01
... considered because of the potential for exceeding the capabilities of the boat while performing the test... method discussed in paragraph (a) of this section, or for certain qualifying boats, the performance test... qualifying under this paragraph, the performance test method described in this paragraph may be used to...
33 CFR 183.53 - Horsepower capacity.
Code of Federal Regulations, 2013 CFR
2013-07-01
... considered because of the potential for exceeding the capabilities of the boat while performing the test... method discussed in paragraph (a) of this section, or for certain qualifying boats, the performance test... qualifying under this paragraph, the performance test method described in this paragraph may be used to...
33 CFR 183.53 - Horsepower capacity.
Code of Federal Regulations, 2012 CFR
2012-07-01
... considered because of the potential for exceeding the capabilities of the boat while performing the test... method discussed in paragraph (a) of this section, or for certain qualifying boats, the performance test... qualifying under this paragraph, the performance test method described in this paragraph may be used to...
High-temperature testing of glass/ceramic matrix composites
NASA Technical Reports Server (NTRS)
Mandell, John F.; Grande, Dodd H.; Dannemann, Kathryn A.
1989-01-01
Recent advances in ceramic and other high-temperature composites have created a need for test methods that can be used at 1000 C and above. Present test methods usually require adhesively bonded tabs that cannot be used at high temperatures. This paper discusses some of the difficulties with high-temperature test development and describes several promising test methods. Stress-strain data are given for Nicalon ceramic fiber reinforced glass and glass-ceramic matrix composites tested in air at temperatures up to 1000 C.
Testing and Validation of the Dynamic Interia Measurement Method
NASA Technical Reports Server (NTRS)
Chin, Alexander; Herrera, Claudia; Spivey, Natalie; Fladung, William; Cloutier, David
2015-01-01
This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.
Teaching Hearing-Impaired Children in Iraq Using a New Teaching Method.
ERIC Educational Resources Information Center
Harris, N. D. C.; Mustafa, N.
1986-01-01
Describes a field test and results of a new didactic teaching method involving resource-based learning to teach various aspects of mathematics and science (fractions, magnetism, planets) to elementary aged hearing impaired student in Iraq. The dramatic improvements in language for learners is described and implications of the methods are…
NOAO testing procedures for large optics
NASA Astrophysics Data System (ADS)
Stepp, Larry M.; Poczulp, Gary A.; Pearson, Earl T.; Roddier, Nicolas A.
1992-03-01
This paper describes optical testing procedures used at the National Optical Astronomy Observatories (NOAO) for testing large optics. It begins with a discussion of the philosophy behind the testing approach and then describes a number of different testing methods used at NOAO, including the wire test, full-aperture and sub-aperture Hartmann testing, and scatterplate interferometry. Specific innovations that enhance the testing capabilities are mentioned. NOAO data reduction software is described. Examples are given of specific output formats that are useful to the optician, using illustrations taken from recent testing of a 3.5- meter, f/1.75 borosilicate honeycomb mirror. Finally, we discuss some of the optical testing challenges posed by the large optics for the Gemini 8-meter Telescopes Project.
Enabling Advanced Wind-Tunnel Research Methods Using the NASA Langley 12-Foot Low Speed Tunnel
NASA Technical Reports Server (NTRS)
Busan, Ronald C.; Rothhaar, Paul M.; Croom, Mark A.; Murphy, Patrick C.; Grafton, Sue B.; O-Neal, Anthony W.
2014-01-01
Design of Experiment (DOE) testing methods were used to gather wind tunnel data characterizing the aerodynamic and propulsion forces and moments acting on a complex vehicle configuration with 10 motor-driven propellers, 9 control surfaces, a tilt wing, and a tilt tail. This paper describes the potential benefits and practical implications of using DOE methods for wind tunnel testing - with an emphasis on describing how it can affect model hardware, facility hardware, and software for control and data acquisition. With up to 23 independent variables (19 model and 2 tunnel) for some vehicle configurations, this recent test also provides an excellent example of using DOE methods to assess critical coupling effects in a reasonable timeframe for complex vehicle configurations. Results for an exploratory test using conventional angle of attack sweeps to assess aerodynamic hysteresis is summarized, and DOE results are presented for an exploratory test used to set the data sampling time for the overall test. DOE results are also shown for one production test characterizing normal force in the Cruise mode for the vehicle.
40 CFR 53.34 - Test procedure for methods for PM10 and Class I methods for PM2.5.
Code of Federal Regulations, 2011 CFR
2011-07-01
... linear regression parameters (slope, intercept, and correlation coefficient) describing the relationship... correlation coefficient. (2) To pass the test for comparability, the slope, intercept, and correlation...
Homogeneity study of fixed-point continuous marine environmental and meteorological data: a review
NASA Astrophysics Data System (ADS)
Yang, Jinkun; Yang, Yang; Miao, Qingsheng; Dong, Mingmei; Wan, Fangfang
2018-02-01
The principle of inhomogeneity and the classification of homogeneity test methods are briefly described, and several common inhomogeneity methods and relative merits are described in detail. Then based on the applications of the different homogeneity methods to the ground meteorological data and marine environment data, the present status and the progress are reviewed. At present, the homogeneity research of radiosonde and ground meteorological data is mature at home and abroad, and the research and application in the marine environmental data should also be given full attention. To carry out a variety of test and correction methods combined with the use of multi-mode test system, will make the results more reasonable and scientific, and also can be used to provide accurate first-hand information for the coastal climate change researches.
ERIC Educational Resources Information Center
Boekkooi-Timminga, Ellen
Nine methods for automated test construction are described. All are based on the concepts of information from item response theory. Two general kinds of methods for the construction of parallel tests are presented: (1) sequential test design; and (2) simultaneous test design. Sequential design implies that the tests are constructed one after the…
This chapter provides a brief introduction to whole effluent toxicity (WET) testing and describes the regulatory background and context of WET testing. This chapter also describes the purpose of this document and outlines the issues addressed in each chapter.
Determining irrigation distribution uniformity and efficiency for nurseries
R. Thomas Fernandez
2010-01-01
A simple method for testing the distribution uniformity of overhead irrigation systems is described. The procedure is described step-by-step along with an example. Other uses of distribution uniformity testing are presented, as well as common situations that affect distribution uniformity and how to alleviate them.
1988-02-01
Environmental effects Method 900 - Background information on environmental effects 78 Method 901 - Method of assessment of diffusivity properties of fibre... environmental conditioning. Strain gauges can sometimes fail during prolonged fatigue testing, and it is therefore prudent to undertake a secondary check...fibre volume fraction of the laminate as described in section 1000. (iv) The environmental history of the specimen prior to test. (v) The environmental
Predicting bending strength of fire-retardant-treated plywood from screw-withdrawal tests
J. E. Winandy; P. K. Lebow; W. Nelson
This report describes the development of a test method and predictive model to estimate the residual bending strength of fire-retardant-treated plywood roof sheathing from measurement of screw-withdrawal force. The preferred test methodology is described in detail. Models were developed to predict loss in mean and lower prediction bounds for plywood bending strength as...
Contact Thermocouple Methodology and Evaluation for Temperature Measurement in the Laboratory
NASA Technical Reports Server (NTRS)
Brewer, Ethan J.; Pawlik, Ralph J.; Krause, David L.
2013-01-01
Laboratory testing of advanced aerospace components very often requires highly accurate temperature measurement and control devices, as well as methods to precisely analyze and predict the performance of such components. Analysis of test articles depends on accurate measurements of temperature across the specimen. Where possible, this task is accomplished using many thermocouples welded directly to the test specimen, which can produce results with great precision. However, it is known that thermocouple spot welds can initiate deleterious cracks in some materials, prohibiting the use of welded thermocouples. Such is the case for the nickel-based superalloy MarM-247, which is used in the high temperature, high pressure heater heads for the Advanced Stirling Converter component of the Advanced Stirling Radioisotope Generator space power system. To overcome this limitation, a method was developed that uses small diameter contact thermocouples to measure the temperature of heater head test articles with the same level of accuracy as welded thermocouples. This paper includes a brief introduction and a background describing the circumstances that compelled the development of the contact thermocouple measurement method. Next, the paper describes studies performed on contact thermocouple readings to determine the accuracy of results. It continues on to describe in detail the developed measurement method and the evaluation of results produced. A further study that evaluates the performance of different measurement output devices is also described. Finally, a brief conclusion and summary of results is provided.
Borycki, E; Kushniruk, A; Nohr, C; Takeda, H; Kuwata, S; Carvalho, C; Bainbridge, M; Kannry, J
2013-01-01
Issues related to lack of system usability and potential safety hazards continue to be reported in the health information technology (HIT) literature. Usability engineering methods are increasingly used to ensure improved system usability and they are also beginning to be applied more widely for ensuring the safety of HIT applications. These methods are being used in the design and implementation of many HIT systems. In this paper we describe evidence-based approaches to applying usability engineering methods. A multi-phased approach to ensuring system usability and safety in healthcare is described. Usability inspection methods are first described including the development of evidence-based safety heuristics for HIT. Laboratory-based usability testing is then conducted under artificial conditions to test if a system has any base level usability problems that need to be corrected. Usability problems that are detected are corrected and then a new phase is initiated where the system is tested under more realistic conditions using clinical simulations. This phase may involve testing the system with simulated patients. Finally, an additional phase may be conducted, involving a naturalistic study of system use under real-world clinical conditions. The methods described have been employed in the analysis of the usability and safety of a wide range of HIT applications, including electronic health record systems, decision support systems and consumer health applications. It has been found that at least usability inspection and usability testing should be applied prior to the widespread release of HIT. However, wherever possible, additional layers of testing involving clinical simulations and a naturalistic evaluation will likely detect usability and safety issues that may not otherwise be detected prior to widespread system release. The framework presented in the paper can be applied in order to develop more usable and safer HIT, based on multiple layers of evidence.
40 CFR 53.3 - General requirements for an equivalent method determination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted... 40 Protection of Environment 6 2012-07-01 2012-07-01 false General requirements for an equivalent method determination. 53.3 Section 53.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
40 CFR 53.3 - General requirements for an equivalent method determination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted... 40 Protection of Environment 5 2011-07-01 2011-07-01 false General requirements for an equivalent method determination. 53.3 Section 53.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
40 CFR 53.3 - General requirements for an equivalent method determination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted... 40 Protection of Environment 6 2014-07-01 2014-07-01 false General requirements for an equivalent method determination. 53.3 Section 53.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
40 CFR 53.3 - General requirements for an equivalent method determination.
Code of Federal Regulations, 2013 CFR
2013-07-01
... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted... 40 Protection of Environment 6 2013-07-01 2013-07-01 false General requirements for an equivalent method determination. 53.3 Section 53.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
The Noninvasive Measurement of X-Ray Tube Potential.
NASA Astrophysics Data System (ADS)
Ranallo, Frank Nunzio
In this thesis I briefly describe the design of clinical x-ray imaging systems and also the various methods of measuring x-ray tube potential, both invasive and noninvasive. I also discuss the meaning and usage of the quantities tube potential (kV) and peak tube potential (kVp) with reference to x-ray systems used in medical imaging. I propose that there exist several quantities which describe different important aspects of the tube potential as a function of time. These quantities are measurable and can be well defined. I have developed a list of definitions of these quantities along with suggested names and symbols. I describe the development and physical principles of a superior noninvasive method of tube potential measurement along with the instrumentation used to implement this method. This thesis research resulted in the development of several commercial kVp test devices (or "kVp Meters") for which the actual measurement procedure is simple, rapid, and reliable compared to other methods, invasive or noninvasive. These kVp test devices provide measurements with a high level of accuracy and reliability over a wide range of test conditions. They provide results which are more reliable and clinically meaningful than many other, more primary and invasive methods. The errors inherent in these new kVp test devices were investigated and methods to minimize them are discussed.
Flexible Transcription Testing
ERIC Educational Resources Information Center
Carr-Smith, Norma
1976-01-01
Flexible structure in a San Francisco State University shorthand course is described as a way to provide motivation for students. Topics discussed are transcription testing plan, method of evaluation, practice tests, increasing difficulty of tests, and classroom results. (TA)
ANALYSIS OF ALDEHYDES AND KETONES IN THE GAS PHASE
The development and testing of a 2,4-dinitrophenylhydrazine-acetonitrile (DNPH-ACN) method for the analysis of aldehydes and ketones in ambient air are described. A discussion of interferences, preparation of calibration standards, analytical testing, fluorescence methods and car...
NASA Astrophysics Data System (ADS)
Kliuev, V. V.
Data on the general design and principles of operation of various instruments and systems for the nondestructive testing of materials and products of various kinds are presented, and test procedures are described. Methods discussed include optical, thermal, capillary, RF, and X-ray testing techniques. The discussion also covers magnetic, electromagnetic, eddy-current, acoustic, and combined nondestructive testing methods.
Hearing Aid–Related Standards and Test Systems
Ravn, Gert; Preves, David
2015-01-01
Many documents describe standardized methods and standard equipment requirements in the field of audiology and hearing aids. These standards will ensure a uniform level and a high quality of both the methods and equipment used in audiological work. The standards create the basis for measuring performance in a reproducible manner and independent from how and when and by whom parameters have been measured. This article explains, and focuses on, relevant acoustic and electromagnetic compatibility parameters and describes several test systems available. PMID:27516709
McAdams, Wm.A.; Foss, M.H.
1958-08-12
A method of testing containers for leaks is described, particularly the testing of containers or cans in which the uranium slugs for nuelear reactors are jacketed. This method involves the immersion of the can in water under l50 pounds of pressure, then removing, drying, and coating the can with anhydrous copper sulfate. Amy water absorbed by the can under pressure will exude and discolor the copper sulfate in the area about the leak.
TROPICAL COLLECTOR URCHIN, TRIPNEUSTES GRATILLA, FERTILIZATION TEST METHOD
This document describes a fertilization method to estimate the chronic toxicity of effluents and receiving waters to the gametes of the tropical sea urchin (Tripneustes gratilla). This toxicity test measures the fertilizing capacity of sperm following a static, non-renewal 60-mi...
Grey, Katherine R; Warshaw, Erin M
Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.
Benefits of Using Planned Comparisons Rather Than Post Hoc Tests: A Brief Review with Examples.
ERIC Educational Resources Information Center
DuRapau, Theresa M.
The rationale behind analysis of variance (including analysis of covariance and multiple analyses of variance and covariance) methods is reviewed, and unplanned and planned methods of evaluating differences between means are briefly described. Two advantages of using planned or a priori tests over unplanned or post hoc tests are presented. In…
Water monitor system: Phase 1 test report
NASA Technical Reports Server (NTRS)
Taylor, R. E.; Jeffers, E. L.
1976-01-01
Automatic water monitor system was tested with the objectives of assuring high-quality effluent standards and accelerating the practice of reclamation and reuse of water. The NASA water monitor system is described. Various components of the system, including the necessary sensors, the sample collection system, and the data acquisition and display system, are discussed. The test facility and the analysis methods are described. Test results are reviewed, and recommendations for water monitor system design improvement are presented.
NASA Technical Reports Server (NTRS)
Goodyer, M. J.
1982-01-01
Data obtained from the boundary of a test section provides information on the model contained within it. A method for extracting some of this data in two dimensional testing is described. Examples of model data are included on lift, pitching moment and wake displacement thickness. A FORTRAN listing is also described, having a form suitable for incorporation into the software package used in the running of such a test section.
Testing methods and techniques: Testing electrical and electronic devices: A compilation
NASA Technical Reports Server (NTRS)
1972-01-01
The methods, techniques, and devices used in testing various electrical and electronic apparatus are presented. The items described range from semiconductor package leak detectors to automatic circuit analyzer and antenna simulators for system checkout. In many cases the approaches can result in considerable cost savings and improved quality control. The testing of various electronic components, assemblies, and systems; the testing of various electrical devices; and the testing of cables and connectors are explained.
Demonstrating Hemostasis with a Student-Designed Prothrombin Time Test
ERIC Educational Resources Information Center
Fardy, Richard Wiley
1978-01-01
Describes a blood coagulation test developed by two high school biology students. Although the test lacks some precision, results indicate that the technique is comparable to standard methods used in laboratories. (MA)
NASA Technical Reports Server (NTRS)
Myhill, Elizabeth A.; Boss, Alan P.
1993-01-01
In Boss & Myhill (1992) we described the derivation and testing of a spherical coordinate-based scheme for solving the hydrodynamic equations governing the gravitational collapse of nonisothermal, nonmagnetic, inviscid, radiative, three-dimensional protostellar clouds. Here we discuss a Cartesian coordinate-based scheme based on the same set of hydrodynamic equations. As with the spherical coorrdinate-based code, the Cartesian coordinate-based scheme employs explicit Eulerian methods which are both spatially and temporally second-order accurate. We begin by describing the hydrodynamic equations in Cartesian coordinates and the numerical methods used in this particular code. Following Finn & Hawley (1989), we pay special attention to the proper implementations of high-order accuracy, finite difference methods. We evaluate the ability of the Cartesian scheme to handle shock propagation problems, and through convergence testing, we show that the code is indeed second-order accurate. To compare the Cartesian scheme discussed here with the spherical coordinate-based scheme discussed in Boss & Myhill (1992), the two codes are used to calculate the standard isothermal collapse test case described by Bodenheimer & Boss (1981). We find that with the improved codes, the intermediate bar-configuration found previously disappears, and the cloud fragments directly into a binary protostellar system. Finally, we present the results from both codes of a new test for nonisothermal protostellar collapse.
MEASUREMENT OF INDOOR AIR EMISSIONS FROM DRY-PROCESS PHOTOCOPY MACHINES
The article provides background information on indoor air emissions from office equipment, with emphasis on dry-process photocopy machines. The test method is described in detail along with results of a study to evaluate the test method using four dry-process photocopy machines. ...
Rivoirard, Romain; Duplay, Vianney; Oriol, Mathieu; Tinquaut, Fabien; Chauvin, Franck; Magne, Nicolas; Bourmaud, Aurelie
2016-01-01
Background Quality of reporting for Randomized Clinical Trials (RCTs) in oncology was analyzed in several systematic reviews, but, in this setting, there is paucity of data for the outcomes definitions and consistency of reporting for statistical tests in RCTs and Observational Studies (OBS). The objective of this review was to describe those two reporting aspects, for OBS and RCTs in oncology. Methods From a list of 19 medical journals, three were retained for analysis, after a random selection: British Medical Journal (BMJ), Annals of Oncology (AoO) and British Journal of Cancer (BJC). All original articles published between March 2009 and March 2014 were screened. Only studies whose main outcome was accompanied by a corresponding statistical test were included in the analysis. Studies based on censored data were excluded. Primary outcome was to assess quality of reporting for description of primary outcome measure in RCTs and of variables of interest in OBS. A logistic regression was performed to identify covariates of studies potentially associated with concordance of tests between Methods and Results parts. Results 826 studies were included in the review, and 698 were OBS. Variables were described in Methods section for all OBS studies and primary endpoint was clearly detailed in Methods section for 109 RCTs (85.2%). 295 OBS (42.2%) and 43 RCTs (33.6%) had perfect agreement for reported statistical test between Methods and Results parts. In multivariable analysis, variable "number of included patients in study" was associated with test consistency: aOR (adjusted Odds Ratio) for third group compared to first group was equal to: aOR Grp3 = 0.52 [0.31–0.89] (P value = 0.009). Conclusion Variables in OBS and primary endpoint in RCTs are reported and described with a high frequency. However, statistical tests consistency between methods and Results sections of OBS is not always noted. Therefore, we encourage authors and peer reviewers to verify consistency of statistical tests in oncology studies. PMID:27716793
ERIC Educational Resources Information Center
Dahabreh, Issa J.; Chung, Mei; Kitsios, Georgios D.; Terasawa, Teruhiko; Raman, Gowri; Tatsioni, Athina; Tobar, Annette; Lau, Joseph; Trikalinos, Thomas A.; Schmid, Christopher H.
2013-01-01
We performed a survey of meta-analyses of test performance to describe the evolution in their methods and reporting. Studies were identified through MEDLINE (1966-2009), reference lists, and relevant reviews. We extracted information on clinical topics, literature review methods, quality assessment, and statistical analyses. We reviewed 760…
NASA Technical Reports Server (NTRS)
Chin, Alexander; Herrera, Claudia; Spivey, Natalie; Fladung, William; Cloutier, David
2015-01-01
This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.
EMC Test Challenges for NASAs James Webb Space Telescope
NASA Technical Reports Server (NTRS)
McCloskey, John
2016-01-01
This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.
EMC Test Challenges for NASA's James Webb Space Telescope
NASA Technical Reports Server (NTRS)
McCloskey, John
2016-01-01
This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.
A General Model for Testing Mediation and Moderation Effects
MacKinnon, David P.
2010-01-01
This paper describes methods for testing mediation and moderation effects in a dataset, both together and separately. Investigations of this kind are especially valuable in prevention research to obtain information on the process by which a program achieves its effects and whether the program is effective for subgroups of individuals. A general model that simultaneously estimates mediation and moderation effects is presented, and the utility of combining the effects into a single model is described. Possible effects of interest in the model are explained, as are statistical methods to assess these effects. The methods are further illustrated in a hypothetical prevention program example. PMID:19003535
A New Method for Incremental Testing of Finite State Machines
NASA Technical Reports Server (NTRS)
Pedrosa, Lehilton Lelis Chaves; Moura, Arnaldo Vieira
2010-01-01
The automatic generation of test cases is an important issue for conformance testing of several critical systems. We present a new method for the derivation of test suites when the specification is modeled as a combined Finite State Machine (FSM). A combined FSM is obtained conjoining previously tested submachines with newly added states. This new concept is used to describe a fault model suitable for incremental testing of new systems, or for retesting modified implementations. For this fault model, only the newly added or modified states need to be tested, thereby considerably reducing the size of the test suites. The new method is a generalization of the well-known W-method and the G-method, but is scalable, and so it can be used to test FSMs with an arbitrarily large number of states.
Creep behavior of bone cement: a method for time extrapolation using time-temperature equivalence.
Morgan, R L; Farrar, D F; Rose, J; Forster, H; Morgan, I
2003-04-01
The clinical lifetime of poly(methyl methacrylate) (PMMA) bone cement is considerably longer than the time over which it is convenient to perform creep testing. Consequently, it is desirable to be able to predict the long term creep behavior of bone cement from the results of short term testing. A simple method is described for prediction of long term creep using the principle of time-temperature equivalence in polymers. The use of the method is illustrated using a commercial acrylic bone cement. A creep strain of approximately 0.6% is predicted after 400 days under a constant flexural stress of 2 MPa. The temperature range and stress levels over which it is appropriate to perform testing are described. Finally, the effects of physical aging on the accuracy of the method are discussed and creep data from aged cement are reported.
How to detect carbapenemase producers? A literature review of phenotypic and molecular methods.
Hammoudi, D; Moubareck, C Ayoub; Sarkis, D Karam
2014-12-01
This review describes the current state-of-art of carbapenemase detection methods. Identification of carbapenemases is first based on conventional phenotypic tests including antimicrobial susceptibility testing, modified-Hodge test and carbapenemase-inhibitor culture tests. Second, molecular characterization of carbapenemase genes by PCR sequencing is essential. Third, innovative biochemical and spectrometric detection may be applied. Copyright © 2014 Elsevier B.V. All rights reserved.
[Environmental Education Units.] Soil Sampling. Stream Profiles. Tree Watching. Plant Puzzles.
ERIC Educational Resources Information Center
Minneapolis Independent School District 275, Minn.
Five of these eleven units describe methods elementary school students can use when studying soil characteristics. Soil nitrogen and water holding capacity tests are included with two techniques for measuring soil pH. Survey methods for soil organisms are suggested. The remaining pamphlets describe diverse activities associated with field…
Rapid evaluation of reverse-osmosis membranes
NASA Technical Reports Server (NTRS)
Hollahan, J. R.; Wydeven, T.
1972-01-01
Simultaneous reverse-osmosis tests conducted with centrifuges having multiple compartment heads are discussed. Equipment for retaining reverse-osmosis membrane is illustrated. Method of conducting tests is described.
Code of Federal Regulations, 2013 CFR
2013-10-01
... machine. An acceptable method for measuring the concentration of carbon dioxide is described in Bureau of Mines Report of Investigations 6865, A Machine-Test Method for Measuring Carbon Dioxide in the Inspired... of 10.5 liters. (3) A sedentary breathing machine cam will be used. (4) The apparatus will be tested...
Code of Federal Regulations, 2012 CFR
2012-10-01
... machine. An acceptable method for measuring the concentration of carbon dioxide is described in Bureau of Mines Report of Investigations 6865, A Machine-Test Method for Measuring Carbon Dioxide in the Inspired... of 10.5 liters. (3) A sedentary breathing machine cam will be used. (4) The apparatus will be tested...
Code of Federal Regulations, 2014 CFR
2014-10-01
... machine. An acceptable method for measuring the concentration of carbon dioxide is described in Bureau of Mines Report of Investigations 6865, A Machine-Test Method for Measuring Carbon Dioxide in the Inspired... of 10.5 liters. (3) A sedentary breathing machine cam will be used. (4) The apparatus will be tested...
A Model-Based Method for Content Validation of Automatically Generated Test Items
ERIC Educational Resources Information Center
Zhang, Xinxin; Gierl, Mark
2016-01-01
The purpose of this study is to describe a methodology to recover the item model used to generate multiple-choice test items with a novel graph theory approach. Beginning with the generated test items and working backward to recover the original item model provides a model-based method for validating the content used to automatically generate test…
Building America Top Innovations 2014 Profile: HVAC Cabinet Air Leakage Test Method
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This 2014 Top Innovation profile describes Building America-funded research by teams and national laboratories that resulted in the development of an ASHRAE standard and a standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets and has spurred equipment manufacturers to tighten the cabinets they use for residential HVAC systems.
Electro-impulse de-icing testing analysis and design
NASA Technical Reports Server (NTRS)
Zumwalt, G. W.; Schrag, R. L.; Bernhart, W. D.; Friedberg, R. A.
1988-01-01
Electro-Impulse De-Icing (EIDI) is a method of ice removal by sharp blows delivered by a transient electromagnetic field. Detailed results are given for studies of the electrodynamic phenomena. Structural dynamic tests and computations are described. Also reported are ten sets of tests at NASA's Icing Research Tunnel and flight tests by NASA and Cessna Aircraft Company. Fabrication of system components are described and illustrated. Fatigue and electromagnetic interference tests are reported. Here, the necessary information for the design of an EIDI system for aircraft is provided.
Using the Draw-a-Scientist Test for Inquiry and Evaluation
ERIC Educational Resources Information Center
Miele, Eleanor
2014-01-01
The Draw-a-Scientist Test (DAST) is a tool to assess stereotypical imagery of scientists. This paper describes the use of the DAST as both a model for inquiry and as a method of assessing the affective domain. The DAST was administered in a science education methods course for undergraduate students of elementary education, a methods course for…
43 CFR 11.64 - Injury determination phase-testing and sampling methods.
Code of Federal Regulations, 2010 CFR
2010-10-01
... paragraphs (b), (c), (d), (e), and (f) of this section. (b) Surface water resources. (1) Testing and sampling for injury to surface water resources shall be performed using methodologies described in the... for surface water resources shall be conducted in accordance with methods that are generally accepted...
43 CFR 11.64 - Injury determination phase-testing and sampling methods.
Code of Federal Regulations, 2011 CFR
2011-10-01
... paragraphs (b), (c), (d), (e), and (f) of this section. (b) Surface water resources. (1) Testing and sampling for injury to surface water resources shall be performed using methodologies described in the... for surface water resources shall be conducted in accordance with methods that are generally accepted...
A Synthesis of the Research on Alternative Assessment Methods in Teacher Education.
ERIC Educational Resources Information Center
Glowacki, Margaret L.; Steele, D. Joyce
This synthesis of research on alternative assessment methods in teacher education reviews literature on performance assessment, describing the various types of assessment discussed by M. Priestley (1982), including: (1) actual performance assessments (work-sample tests, identification tests, supervisor ratings, peer ratings, and self-assessments);…
ERIC Educational Resources Information Center
Armour, M. A.; And Others
1985-01-01
Describes procedures for disposing of dichromate cleaning solution, picric acid, organic azides, oxalic acid, chemical spills, and hydroperoxides in ethers and alkenes. These methods have been tested under laboratory conditions and are specific for individual chemicals rather than for groups of chemicals. (JN)
Concept Development for Future Domains: A New Method of Knowledge Elicitation
2005-06-01
Procedure: U.S. Army Research Institute for the Behavioral and Social Sciences (ARI) examined methods to generate, refine, test , and validate new...generate, elaborate, refine, describe, test , and validate new Future Force concepts relating to doctrine, tactics, techniques, procedures, unit and team...System (Harvey, 1993), and the Job Element Method (Primoff & Eyde , 1988). Figure 1 provides a more comprehensive list of task analytic methods. Please see
ERIC Educational Resources Information Center
Londeree, Ben R.
1981-01-01
Postural deviations resulting from strength and flexibility imbalances include swayback, scoliosis, and rounded shoulders. Screening tests are one method for identifying strength problems. Tests for the evaluation of postural problems are described, and exercises are presented for the strengthening of muscles. (JN)
Hardware Demonstration: Radiated Emissions as a Function of Common Mode Current
NASA Technical Reports Server (NTRS)
Mc Closkey, John; Roberts, Jen
2016-01-01
This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.
NASA Technical Reports Server (NTRS)
Kashangaki, Thomas A. L.
1992-01-01
This paper describes a series of modal tests that were performed on a cantilevered truss structure. The goal of the tests was to assemble a large database of high quality modal test data for use in verification of proposed methods for on orbit model verification and damage detection in flexible truss structures. A description of the hardware is provided along with details of the experimental setup and procedures for 16 damage cases. Results from selected cases are presented and discussed. Differences between ground vibration testing and on orbit modal testing are also described.
CADDIS Volume 4. Data Analysis: Selecting an Analysis Approach
An approach for selecting statistical analyses to inform causal analysis. Describes methods for determining whether test site conditions differ from reference expectations. Describes an approach for estimating stressor-response relationships.
Evaluation of clinical methods for peroneal muscle testing.
Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot
2013-03-01
Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described frequencies. Inconsistencies were identified between the instruction method commonly provided for peroneal muscle testing in textbook and the functional anatomy of these muscles. Results reflect the lack of accuracy in applying functional anatomy to peroneal testing. This may be due to limited use of peroneal muscle testing or to inadequate investigation of the existing evaluation methods and their validity. Accordingly, teaching materials and clinical methods used for this test should be re-evaluated. Further research should investigate the value of peroneal muscle testing in clinical ankle evaluation. Copyright © 2012 John Wiley & Sons, Ltd.
A Method for Implementing Force-Limited Vibration Control
NASA Technical Reports Server (NTRS)
Worth, Daniel B.
1997-01-01
NASA/GSFC has implemented force-limited vibration control on a controller which can only accept one profile. The method uses a personal computer based digital signal processing board to convert force and/or moment signals into what appears to he an acceleration signal to the controller. This technique allows test centers with older controllers to use the latest force-limited control techniques for random vibration testing. The paper describes the method, hardware, and test procedures used. An example from a test performed at NASA/GSFC is used as a guide.
Tools and techniques for estimating high intensity RF effects
NASA Astrophysics Data System (ADS)
Zacharias, Richard L.; Pennock, Steve T.; Poggio, Andrew J.; Ray, Scott L.
1992-01-01
Tools and techniques for estimating and measuring coupling and component disturbance for avionics and electronic controls are described. A finite-difference-time-domain (FD-TD) modeling code, TSAR, used to predict coupling is described. This code can quickly generate a mesh model to represent the test object. Some recent applications as well as the advantages and limitations of using such a code are described. Facilities and techniques for making low-power coupling measurements and for making direct injection test measurements of device disturbance are also described. Some scaling laws for coupling and device effects are presented. A method for extrapolating these low-power test results to high-power full-system effects are presented.
Multiple IMU system development, volume 1
NASA Technical Reports Server (NTRS)
Landey, M.; Mckern, R.
1974-01-01
A redundant gimballed inertial system is described. System requirements and mechanization methods are defined and hardware and software development is described. Failure detection and isolation algorithms are presented and technology achievements described. Application of the system as a test tool for shuttle avionics concepts is outlined.
Solar panel thermal cycling testing by solar simulation and infrared radiation methods
NASA Technical Reports Server (NTRS)
Nuss, H. E.
1980-01-01
For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.
A Tool for Requirements-Based Programming
NASA Technical Reports Server (NTRS)
Rash, James L.; Hinchey, Michael G.; Rouff, Christopher A.; Gracanin, Denis; Erickson, John
2005-01-01
Absent a general method for mathematically sound, automated transformation of customer requirements into a formal model of the desired system, developers must resort to either manual application of formal methods or to system testing (either manual or automated). While formal methods have afforded numerous successes, they present serious issues, e.g., costs to gear up to apply them (time, expensive staff), and scalability and reproducibility when standards in the field are not settled. The testing path cannot be walked to the ultimate goal, because exhaustive testing is infeasible for all but trivial systems. So system verification remains problematic. System or requirements validation is similarly problematic. The alternatives available today depend on either having a formal model or pursuing enough testing to enable the customer to be certain that system behavior meets requirements. The testing alternative for non-trivial systems always have some system behaviors unconfirmed and therefore is not the answer. To ensure that a formal model is equivalent to the customer s requirements necessitates that the customer somehow fully understands the formal model, which is not realistic. The predominant view that provably correct system development depends on having a formal model of the system leads to a desire for a mathematically sound method to automate the transformation of customer requirements into a formal model. Such a method, an augmentation of requirements-based programming, will be briefly described in this paper, and a prototype tool to support it will be described. The method and tool enable both requirements validation and system verification for the class of systems whose behavior can be described as scenarios. An application of the tool to a prototype automated ground control system for NASA mission is presented.
Antianaerobic Antimicrobials: Spectrum and Susceptibility Testing
Wexler, Hannah M.; Goldstein, Ellie J. C.
2013-01-01
SUMMARY Susceptibility testing of anaerobic bacteria recovered from selected cases can influence the choice of antimicrobial therapy. The Clinical and Laboratory Standards Institute (CLSI) has standardized many laboratory procedures, including anaerobic susceptibility testing (AST), and has published documents for AST. The standardization of testing methods by the CLSI allows comparisons of resistance trends among various laboratories. Susceptibility testing should be performed on organisms recovered from sterile body sites, those that are isolated in pure culture, or those that are clinically important and have variable or unique susceptibility patterns. Organisms that should be considered for individual isolate testing include highly virulent pathogens for which susceptibility cannot be predicted, such as Bacteroides, Prevotella, Fusobacterium, and Clostridium spp.; Bilophila wadsworthia; and Sutterella wadsworthensis. This review describes the current methods for AST in research and reference laboratories. These methods include the use of agar dilution, broth microdilution, Etest, and the spiral gradient endpoint system. The antimicrobials potentially effective against anaerobic bacteria include beta-lactams, combinations of beta-lactams and beta-lactamase inhibitors, metronidazole, chloramphenicol, clindamycin, macrolides, tetracyclines, and fluoroquinolones. The spectrum of efficacy, antimicrobial resistance mechanisms, and resistance patterns against these agents are described. PMID:23824372
Impetus of composite mechanics on test methods for fiber composites
NASA Technical Reports Server (NTRS)
Chamis, C. C.
1978-01-01
The impetus of composite mechanics on composite test methods and/or on interpreting test results is described by using examples from composite micromechanics, composite macromechanics and laminate theory. The specific examples included contributions such as criteria for selecting resin matrices for improved composite strength, the 10 deg off-axis tensile test, criteria for configuring hybrids and superhybrids for improved impact resistance and the reduced bending rigidities concept for buckling and vibration analyses.
Trichinella diagnostics and control: mandatory and best practices for ensuring food safety.
Gajadhar, Alvin A; Pozio, Edoardo; Gamble, H Ray; Nöckler, Karsten; Maddox-Hyttel, Charlotte; Forbes, Lorry B; Vallée, Isabelle; Rossi, Patrizia; Marinculić, Albert; Boireau, Pascal
2009-02-23
Because of its role in human disease, there are increasing global requirements for reliable diagnostic and control methods for Trichinella in food animals to ensure meat safety and to facilitate trade. Consequently, there is a need for standardization of methods, programs, and best practices used in the control of Trichinella and trichinellosis. This review article describes the biology and epidemiology of Trichinella, and describes recommended test methods as well as modified and optimized procedures that are used in meat inspection programs. The use of ELISA for monitoring animals for infection in various porcine and equine pre- and post-slaughter programs, including farm or herd certification programs is also discussed. A brief review of the effectiveness of meat processing methods, such as freezing, cooking and preserving is provided. The importance of proper quality assurance and its application in all aspects of a Trichinella diagnostic system is emphasized. It includes the use of international quality standards, test validation and standardization, critical control points, laboratory accreditation, certification of analysts and proficiency testing. Also described, are the roles and locations of international and regional reference laboratories for trichinellosis where expert advice and support on research and diagnostics are available.
Hirschfeld, Gerrit; Blankenburg, Markus R; Süß, Moritz; Zernikow, Boris
2015-01-01
The assessment of somatosensory function is a cornerstone of research and clinical practice in neurology. Recent initiatives have developed novel protocols for quantitative sensory testing (QST). Application of these methods led to intriguing findings, such as the presence lower pain-thresholds in healthy children compared to healthy adolescents. In this article, we (re-) introduce the basic concepts of signal detection theory (SDT) as a method to investigate such differences in somatosensory function in detail. SDT describes participants' responses according to two parameters, sensitivity and response-bias. Sensitivity refers to individuals' ability to discriminate between painful and non-painful stimulations. Response-bias refers to individuals' criterion for giving a "painful" response. We describe how multilevel models can be used to estimate these parameters and to overcome central critiques of these methods. To provide an example we apply these methods to data from the mechanical pain sensitivity test of the QST protocol. The results show that adolescents are more sensitive to mechanical pain and contradict the idea that younger children simply use more lenient criteria to report pain. Overall, we hope that the wider use of multilevel modeling to describe somatosensory functioning may advance neurology research and practice.
Synthesis of active controls for flutter suppression on a flight research wing
NASA Technical Reports Server (NTRS)
Abel, I.; Perry, B., III; Murrow, H. N.
1977-01-01
This paper describes some activities associated with the preliminary design of an active control system for flutter suppression capable of demonstrating a 20% increase in flutter velocity. Results from two control system synthesis techniques are given. One technique uses classical control theory, and the other uses an 'aerodynamic energy method' where control surface rates or displacements are minimized. Analytical methods used to synthesize the control systems and evaluate their performance are described. Some aspects of a program for flight testing the active control system are also given. This program, called DAST (Drones for Aerodynamics and Structural Testing), employs modified drone-type vehicles for flight assessments and validation testing.
Estimating the Cost of Standardized Student Testing in the United States.
ERIC Educational Resources Information Center
Phelps, Richard P.
2000-01-01
Describes and contrasts different methods of estimating costs of standardized testing. Using a cost-accounting approach, compares gross and marginal costs and considers testing objects (test materials and services, personnel and student time, and administrative/building overhead). Social marginal costs of replacing existing tests with a national…
Procedure for Determining Speed and Climbing Performance of Airships
NASA Technical Reports Server (NTRS)
Thompson, F L
1936-01-01
The procedure for obtaining air-speed and rate-of-climb measurements in performance tests of airships is described. Two methods of obtaining speed measurements, one by means of instruments in the airship and the other by flight over a measured ground course, are explained. Instruments, their calibrations, necessary correction factors, observations, and calculations are detailed for each method, and also for the rate-of-climb tests. A method of correction for the effect on density of moist air and a description of other methods of speed course testing are appended.
Quasi-Uniform High Speed Foam Crush Testing Using a Guided Drop Mass Impact
NASA Technical Reports Server (NTRS)
Jones, Lisa E. (Technical Monitor); Kellas, Sotiris
2004-01-01
A relatively simple method for measuring the dynamic crush response of foam materials at various loading rates is described. The method utilizes a drop mass impact configuration with mass and impact velocity selected such that the crush speed remains approximately uniform during the entire sample crushing event. Instrumentation, data acquisition, and data processing techniques are presented, and limitations of the test method are discussed. The objective of the test method is to produce input data for dynamic finite element modeling involving crash and energy absorption characteristics of foam materials.
NASA Astrophysics Data System (ADS)
Ishizawa, Y.; Abe, K.; Shirako, G.; Takai, T.; Kato, H.
The electromagnetic compatibility (EMC) control method, system EMC analysis method, and system test method which have been applied to test the components of the MOS-1 satellite are described. The merits and demerits of the problem solving, specification, and system approaches to EMC control are summarized, and the data requirements of the SEMCAP (specification and electromagnetic compatibility analysis program) computer program for verifying the EMI safety margin of the components are sumamrized. Examples of EMC design are mentioned, and the EMC design process and selection method for EMC critical points are shown along with sample EMC test results.
ERIC Educational Resources Information Center
Talesnick, Irwin, Ed.
1983-01-01
Describes experiments on diffusion of gases, volumetric approach to water of hydration, and toxicity of chemicals in the laboratory. Also describes an inexpensive automatic pipette, overhead projection of chemical reactions, and an alternative method for demonstrating flame tests. (JN)
NASA Technical Reports Server (NTRS)
Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.
2001-01-01
This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.
Comparison of Artificial Compressibility Methods
NASA Technical Reports Server (NTRS)
Kiris, Cetin; Housman, Jeffrey; Kwak, Dochan
2004-01-01
Various artificial compressibility methods for calculating the three-dimensional incompressible Navier-Stokes equations are compared. Each method is described and numerical solutions to test problems are conducted. A comparison based on convergence behavior, accuracy, and robustness is given.
A new method for flight test determination of propulsive efficiency and drag coefficient
NASA Technical Reports Server (NTRS)
Bull, G.; Bridges, P. D.
1983-01-01
A flight test method is described from which propulsive efficiency as well as parasite and induced drag coefficients can be directly determined using relatively simple instrumentation and analysis techniques. The method uses information contained in the transient response in airspeed for a small power change in level flight in addition to the usual measurement of power required for level flight. Measurements of pitch angle and longitudinal and normal acceleration are eliminated. The theoretical basis for the method, the analytical techniques used, and the results of application of the method to flight test data are presented.
Rivoirard, Romain; Duplay, Vianney; Oriol, Mathieu; Tinquaut, Fabien; Chauvin, Franck; Magne, Nicolas; Bourmaud, Aurelie
2016-01-01
Quality of reporting for Randomized Clinical Trials (RCTs) in oncology was analyzed in several systematic reviews, but, in this setting, there is paucity of data for the outcomes definitions and consistency of reporting for statistical tests in RCTs and Observational Studies (OBS). The objective of this review was to describe those two reporting aspects, for OBS and RCTs in oncology. From a list of 19 medical journals, three were retained for analysis, after a random selection: British Medical Journal (BMJ), Annals of Oncology (AoO) and British Journal of Cancer (BJC). All original articles published between March 2009 and March 2014 were screened. Only studies whose main outcome was accompanied by a corresponding statistical test were included in the analysis. Studies based on censored data were excluded. Primary outcome was to assess quality of reporting for description of primary outcome measure in RCTs and of variables of interest in OBS. A logistic regression was performed to identify covariates of studies potentially associated with concordance of tests between Methods and Results parts. 826 studies were included in the review, and 698 were OBS. Variables were described in Methods section for all OBS studies and primary endpoint was clearly detailed in Methods section for 109 RCTs (85.2%). 295 OBS (42.2%) and 43 RCTs (33.6%) had perfect agreement for reported statistical test between Methods and Results parts. In multivariable analysis, variable "number of included patients in study" was associated with test consistency: aOR (adjusted Odds Ratio) for third group compared to first group was equal to: aOR Grp3 = 0.52 [0.31-0.89] (P value = 0.009). Variables in OBS and primary endpoint in RCTs are reported and described with a high frequency. However, statistical tests consistency between methods and Results sections of OBS is not always noted. Therefore, we encourage authors and peer reviewers to verify consistency of statistical tests in oncology studies.
Survey and Experimental Testing of Nongravimetric Mass Measurement Devices
NASA Technical Reports Server (NTRS)
Oakey, W. E.; Lorenz, R.
1977-01-01
Documentation presented describes the design, testing, and evaluation of an accelerated gravimetric balance, a low mass air bearing oscillator of the spring-mass type, and a centrifugal device for liquid mass measurement. A direct mass readout method was developed to replace the oscillation period readout method which required manual calculations to determine mass. A protoype 25 gram capacity micro mass measurement device was developed and tested.
2013-07-01
experimental requirements of the research are described (See Appendix A for a full description of the development and testing ). 3.1.3 The Black...41 3. TEST SYSTEM USED FOR THE RESEARCH ...Chapter 3: Test system used for the research A complex socio-technical system is required to compare the methods. An emulation of a radar warning
Microfluidic "Pouch" Chips for Immunoassays and Nucleic Acid Amplification Tests.
Mauk, Michael G; Liu, Changchun; Qiu, Xianbo; Chen, Dafeng; Song, Jinzhao; Bau, Haim H
2017-01-01
Microfluidic cassettes ("chips") for processing and analysis of clinical specimens and other sample types facilitate point-of-care (POC) immunoassays and nucleic acid based amplification tests. These single-use test chips can be self-contained and made amenable to autonomous operation-reducing or eliminating supporting instrumentation-by incorporating laminated, pliable "pouch" and membrane structures for fluid storage, pumping, mixing, and flow control. Materials and methods for integrating flexible pouch compartments and diaphragm valves into hard plastic (e.g., acrylic and polycarbonate) microfluidic "chips" for reagent storage, fluid actuation, and flow control are described. We review several versions of these pouch chips for immunoassay and nucleic acid amplification tests, and describe related fabrication techniques. These protocols thus offer a "toolbox" of methods for storage, pumping, and flow control functions in microfluidic devices.
Illustrating Newton's Second Law with the Automobile Coast-Down Test.
ERIC Educational Resources Information Center
Bryan, Ronald A.; And Others
1988-01-01
Describes a run test of automobiles for applying Newton's second law of motion and the concept of power. Explains some automobile thought-experiments and provides the method and data of an actual coast-down test. (YP)
Energy saving concepts relating to induction generators
NASA Technical Reports Server (NTRS)
Nola, F. J.
1980-01-01
Energy saving concepts relating to induction generators are presented. The first describes a regenerative scheme using an induction generator as a variable load for prime movers under test is described. A method for reducing losses in induction machines used specifically as wind driven generators is also described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, H.
1976-03-09
Design modifications of a five-probe focusing collimator coincidence radioisotope scanning system are described. Clinical applications of the system were tested in phantoms using radioisotopes with short biological half-lives, including /sup 75/Se, /sup 192/Ir, /sup 43/K, /sup 130/I, and /sup 82/Br. Data processing methods are also described. (CH)
R. Sam Williams; Steve Lacher; Corey Halpin; Christopher White
2004-01-01
The focus of this report is to describe the results from seven different sealant formulations exposed for up to 18 months. The methods used to evaluate the data are described, the difficulties encountered in analyzing the data are discussed, and new developments in the test apparatus are presented.
Fatigue Testing of Wing Beam by the Resonance Method
NASA Technical Reports Server (NTRS)
Bleakney, William M
1938-01-01
Preliminary fatigue tests on two aluminum-alloy wing-beam specimens subjected to reversed axial loading are described. The motion used consists in incorporating one or two reciprocating motors in a resonance system of which the specimen is the spring element. A description is given of the reciprocating motors, and of the method of assembling and adjusting the vibrating system. The results indicate that the method is well adapted to fatigue tests of not only uniform wing beams but also wing beams with asymmetrical local reinforcements.
A Principled Way of Assessing Visualization Literacy.
Boy, Jeremy; Rensink, Ronald A; Bertini, Enrico; Fekete, Jean-Daniel
2014-12-01
We describe a method for assessing the visualization literacy (VL) of a user. Assessing how well people understand visualizations has great value for research (e. g., to avoid confounds), for design (e. g., to best determine the capabilities of an audience), for teaching (e. g., to assess the level of new students), and for recruiting (e. g., to assess the level of interviewees). This paper proposes a method for assessing VL based on Item Response Theory. It describes the design and evaluation of two VL tests for line graphs, and presents the extension of the method to bar charts and scatterplots. Finally, it discusses the reimplementation of these tests for fast, effective, and scalable web-based use.
Comparison of measurement methods for capacitive tactile sensors and their implementation
NASA Astrophysics Data System (ADS)
Tarapata, Grzegorz; Sienkiewicz, Rafał
2015-09-01
This paper presents a review of ideas and implementations of measurement methods utilized for capacity measurements in tactile sensors. The paper describes technical method, charge amplification method, generation and as well integration method. Three selected methods were implemented in dedicated measurement system and utilised for capacitance measurements of ourselves made tactile sensors. The tactile sensors tested in this work were fully fabricated with the inkjet printing technology. The tests result were presented and summarised. The charge amplification method (CDC) was selected as the best method for the measurement of the tactile sensors.
Antimicrobial Testing Methods & Procedures: MB-11-05
Describes the methodology for determining the effectiveness of a neutralizer used when testing the tuberculocidal activity of disinfectants against Mycobacterium bovis (BCG) on hard surfaces using liquid, sprays, or towelettes.
49 CFR 173.58 - Assignment of class and division for new explosives.
Code of Federal Regulations, 2010 CFR
2010-10-01
....4 explosives. In addition to the test prescribed in § 173.57 of this subchapter, a substance or... Sensitivity Test, Princess Incendiary Spark Test, DDT Test, and External Fire Test, each as described in the... fragments, occurs in the External Fire Test (Test Method 5(c), or (4) Ignition or explosion occurs in the...
Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asperger, R.G.
1982-08-01
A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12more » refs.)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-09-01
This report describes the test site, equipment, and procedures and presents the data obtained during field testing at G.P.U. Genco Homer City Station, August 19--24, 1997. This was the third of three field tests that the US Environmental Protection Agency (EPA) conducted in 1997 as part of a major study to evaluate potential improvements to Method 3, EPA`s test method for measuring flue gas volumetric flow in stacks. The report also includes a Data Distribution Package, the official, complete repository of the results obtained at the test site.
Formal Functional Test Designs: Bridging the Gap Between Test Requirements and Test Specifications
NASA Technical Reports Server (NTRS)
Hops, Jonathan
1993-01-01
This presentation describes the testing life cycle, the purpose of the test design phase, and test design methods and gives an example application. Also included is a description of Test Representation Language (TRL), a summary of the language, and an example of an application of TRL. A sample test requirement and sample test design are included.
Correlating the EMC analysis and testing methods for space systems in MIL-STD-1541A
NASA Technical Reports Server (NTRS)
Perez, Reinaldo J.
1990-01-01
A study was conducted to improve the correlation between the electromagnetic compatibility (EMC) analysis models stated in MIL-STD-1541A and the suggested testing methods used for space systems. The test and analysis methods outlined in MIL-STD-1541A are described, and a comparative assessment of testing and analysis techniques as they relate to several EMC areas is presented. Suggestions on present analysis and test methods are introduced to harmonize and bring the analysis and testing tools in MIL-STD-1541A into closer agreement. It is suggested that test procedures in MIL-STD-1541A must be improved by providing alternatives to the present use of shielded enclosures as the primary site for such tests. In addition, the alternate use of anechoic chambers and open field test sites must be considered.
Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures
NASA Technical Reports Server (NTRS)
Ungar, Eugene K.; Wright, Sarah E.
2016-01-01
Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the original test and the analysis that showed that the thermocouples had become detached, temporary thermocouple attachment methods assessed in the retest and in the thermocouple attachment test, and makes a recommendation for attachment methods for future tests.
Fire test method for graphite fiber reinforced plastics
NASA Technical Reports Server (NTRS)
Bowles, K. J.
1980-01-01
A potential problem in the use of graphite fiber reinforced resin matrix composites is the dispersal of graphite fibers during accidential fires. Airborne, electrically conductive fibers originating from the burning composites could enter and cause shorting in electrical equipment located in surrounding areas. A test method for assessing the burning characteristics of graphite fiber reinforced composites and the effectiveness of the composites in retaining the graphite fibers has been developed. The method utilizes a modified rate of heat release apparatus. The equipment and the testing procedure are described. The application of the test method to the assessment of composite materials is illustrated for two resin matrix/graphite composite systems.
Testing and Benchmarking a 2014 GM Silverado 6L80 Six Speed Automatic Transmission
Describe the method and test results of EPA’s partial transmission benchmarking process which involves installing both the engine and transmission in an engine dynamometer test cell with the engine wire harness tethered to its vehicle parked outside the test cell.
Dispersion Interactions between Rare Gas Atoms: Testing the London Equation Using ab Initio Methods
ERIC Educational Resources Information Center
Halpern, Arthur M.
2011-01-01
A computational chemistry experiment is described in which students can use advanced ab initio quantum mechanical methods to test the ability of the London equation to account quantitatively for the attractive (dispersion) interactions between rare gas atoms. Using readily available electronic structure applications, students can calculate the…
Validation of an Adaptive Combustion Instability Control Method for Gas-Turbine Engines
NASA Technical Reports Server (NTRS)
Kopasakis, George; DeLaat, John C.; Chang, Clarence T.
2004-01-01
This paper describes ongoing testing of an adaptive control method to suppress high frequency thermo-acoustic instabilities like those found in lean-burning, low emission combustors that are being developed for future aircraft gas turbine engines. The method called Adaptive Sliding Phasor Averaged Control, was previously tested in an experimental rig designed to simulate a combustor with an instability of about 530 Hz. Results published earlier, and briefly presented here, demonstrated that this method was effective in suppressing the instability. Because this test rig did not exhibit a well pronounced instability, a question remained regarding the effectiveness of the control methodology when applied to a more coherent instability. To answer this question, a modified combustor rig was assembled at the NASA Glenn Research Center in Cleveland, Ohio. The modified rig exhibited a more coherent, higher amplitude instability, but at a lower frequency of about 315 Hz. Test results show that this control method successfully reduced the instability pressure of the lower frequency test rig. In addition, due to a certain phenomena discovered and reported earlier, the so called Intra-Harmonic Coupling, a dramatic suppression of the instability was achieved by focusing control on the second harmonic of the instability. These results and their implications are discussed, as well as a hypothesis describing the mechanism of intra-harmonic coupling.
Nondestructive spot test method for magnesium and magnesium alloys
NASA Technical Reports Server (NTRS)
Wilson, M. L. (Inventor)
1973-01-01
A method for spot test identification of magnesium and various magnesium alloys commonly used in aerospace applications is described. The spot test identification involves color codes obtained when several drops of 3 M hydrochloric acid are placed on the surface to be tested. After approximately thirty seconds, two drops of this reacted acid is transferred to each of two depressions in a spot plate for additions of other chemicals with subsequent color changes indicating magnesium or its alloy.
SPF Full-scale emissions test method development status ...
This is a non-technical presentation that is intended to inform ASTM task group members about our intended approach to full-scale emissions testing that includes the application of spray foam in an environmental chamber. The presentation describes the approach to emissions characterization, types of measurement systems employed, and expected outcomes from the planned tests. Purpose of this presentation is to update the ASTM D22.05 work group regarding status of our full-scale emissions test method development.
Photogrammetric technique for in-flight ranging of trailing vortices using entrained balloons
NASA Technical Reports Server (NTRS)
Snow, Walter L.; Burner, Alpheus W.; Goad, William K.
1989-01-01
A method for experimentally determining the radial distance of a probe aircraft from a trailing vortex is described. The method relies on photogrammetric triangulation of targets entrained in the vortex core. The theory and preliminary testing were described using laboratory mock-ups. Solid state video cameras were to provide data at 300 Hz rates. Practical methods for seeding the vortex are under separate investigation and are not addressed.
Engineering sciences area and module performance and failure analysis area
NASA Technical Reports Server (NTRS)
Ross, R. G., Jr.; Runkle, L. D.
1982-01-01
Photovoltaic-array/power-conditioner interface studies are updated. An experiment conducted to evaluate different operating-point strategies, such as constant voltage and pilot cells, and to determine array energy losses when the array is operated off the maximum power points is described. Initial results over a test period of three and a half weeks showed a 2% energy loss when the array is operated at a fixed voltage. Degraded-array studies conducted at NE RES that used a range of simulated common types of degraded I-V curves are reviewed. The instrumentation installed at the JPL field-test site to obtain the irradiance data was described. Experiments using an optical filter to adjust the spectral irradiance of the large-area pulsed solar simulator (LAPSS) to AM1.5 are described. Residential-array research activity is reviewed. Voltage isolation test results are described. Experiments performed on one type of module to determine the relationship between leakage current and temperature are reviewed. An encapsulated-cell testing approach is explained. The test program, data reduction methods, and initial results of long-duration module testing are described.
DOT National Transportation Integrated Search
2005-01-01
This report describes work to develop non-destructive testing methods for concrete pavements. Two methods, for pavement thickness and in-place strength estimation, respectively, were developed and evaluated. The thickness estimation method is based o...
A method for measuring different classes of human immunoglobulins specific for the penicilloyl group
Wheeler, A. W.
1971-01-01
A method is described for the detection of human immunoglobulins of the four main classes specific for the penicilloyl group. The technique is an adaptation of the red cell linked antigen antiglobulin reaction based on the finding that benzyl penicilloylated rabbit γ-globulin, specific for human erythrocytes, reacted specifically with erythrocytes but did not agglutinate them. In turn this complex reacted specifically with human penicilloyl antibody and it was then possible to titrate each immunoglobulin class by the addition of anti-immunoglobulin sera. The method described here was used to compare titres of penicilloyl specific immunoglobulins of the same class between different sera. The test was found to be less sensitive than the hapten modified bacteriophage reduction test but had the advantage that individual immunoglobulin classes could be compared. In the absence of a reliable method for the diagnosis of pencillin allergy, it is hoped that the technique described will be a useful addition to existing in vivo and in vitro methods of determining the antibody response of the patient to the penicilloyl group. PMID:4105475
Wijerathne, Buddhika; Rathnayake, Geetha
2013-01-01
Background Most universities currently practice traditional practical spot tests to evaluate students. However, traditional methods have several disadvantages. Computer-based examination techniques are becoming more popular among medical educators worldwide. Therefore incorporating the computer interface in practical spot testing is a novel concept that may minimize the shortcomings of traditional methods. Assessing students’ attitudes and perspectives is vital in understanding how students perceive the novel method. Methods One hundred and sixty medical students were randomly allocated to either a computer-based spot test (n=80) or a traditional spot test (n=80). The students rated their attitudes and perspectives regarding the spot test method soon after the test. The results were described comparatively. Results Students had higher positive attitudes towards the computer-based practical spot test compared to the traditional spot test. Their recommendations to introduce the novel practical spot test method for future exams and to other universities were statistically significantly higher. Conclusions The computer-based practical spot test is viewed as more acceptable to students than the traditional spot test. PMID:26451213
Joy, Abraham; Anim-Danso, Emmanuel; Kohn, Joachim
2009-01-01
Methods for the detection and estimation of diphosgene and triphosgene are described. These compounds are widely used phosgene precursors which produce an intensely colored purple pentamethine oxonol dye when reacted with 1,3-dimethylbarbituric acid (DBA) and pyridine (or a pyridine derivative). Two quantitative methods are described, based on either UV absorbance or fluorescence of the oxonol dye. Detection limits are ~ 4 µmol/L by UV and <0.4 µmol/L by fluorescence. The third method is a test strip for the simple and rapid detection and semi-quantitative estimation of diphosgene and triphosgene, using a filter paper embedded with dimethylbarbituric acid and poly(4-vinylpyridine). Addition of a test solution to the paper causes a color change from white to light blue at low concentrations and to pink at higher concentrations of triphosgene. The test strip is useful for quick on-site detection of triphosgene and diphosgene in reaction mixtures. The test strip is easy to perform and provides clear signal readouts indicative of the presence of phosgene precursors. The utility of this method was demonstrated by the qualitative determination of residual triphosgene during the production of poly(Bisphenol A carbonate). PMID:19782219
[Microbiology--laboratory examinations for bacterias].
Hen, Renjun; Imafuku, Yuji; Yoshida, Hiroshi
2002-11-01
As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.
NASA Technical Reports Server (NTRS)
Greene, B. E.; Northrup, R. F.
1975-01-01
The efficiency was investigated of curved elements in the design of lightweight structural panels under combined loads of axial compression, inplane shear, and bending. The application is described of technology generated in the initial aluminum program to the design and fabrication of Rene 41 panels for subsequent performance tests at elevated temperature. Optimum designs for two panel configurations are presented. The designs are applicable to hypersonic airplane wing structure, and are designed specifically for testing at elevated temperature in the hypersonic wing test structure located at the NASA Flight Research Center. Fabrication methods developed to produce the Rene panels are described, and test results of smaller structural element specimens are presented to verify the design and fabrication methods used. Predicted strengths of the panels under several proposed elevated temperature test load conditions are presented.
NASA Technical Reports Server (NTRS)
McCloskey, John
2016-01-01
This paper describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft/observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.
Incompleteness of Bluetooth protocol conformance test cases
NASA Astrophysics Data System (ADS)
Wu, Peng; Gao, Qiang
2001-10-01
This paper describes a formal method to verify the completeness of conformance testing, in which not only Implementation Under Test (IUT) is formalized in SDL, but also conformance tester is described in SDL so that conformance testing can be performed in simulator provided with CASE tool. The protocol set considered is Bluetooth, an open wireless communication technology. Our research results show that Bluetooth conformance test specification is not complete in that it has only limited coverage and many important capabilities defined in Bluetooth core specification are not tested. We also give a detail report on the missing test cases against Bluetooth core specification, and provide a guide on further test case generation in the future.
Testing methods and techniques: Environmental testing: A compilation
NASA Technical Reports Server (NTRS)
1971-01-01
Various devices and techniques are described for testing hardware and components in four special environments: low temperature, high temperature, high pressure, and vibration. Items ranging from an automatic calibrator for pressure transducers to a fixture for testing the susceptibility of materials to ignition by electric spark are included.
Round Robin Test of Residual Resistance Ratio of Nb$$_3$$Sn Composite Superconductors
Matsushita, Teruo; Otabe, Edmund Soji; Kim, Dong Ho; ...
2017-12-07
A round robin test of residual resistance ratio (RRR) was performed for Nb 3Sn composite superconductors prepared by internal tin method by six institutes with the international standard test method described in IEC 61788-4. It was found that uncertainty mainly resulted from determination of the cryogenic resistance from the intersection of two straight lines drawn to fit the voltage vs. temperature curve around the resistive transition. As a result, the measurement clarified that RRR can be measured with expanded uncertainty not larger than 5% with the coverage factor 2 by using this test method.
Method and apparatus for tensile testing of metal foil
NASA Technical Reports Server (NTRS)
Wade, O. W. (Inventor)
1976-01-01
A method for obtaining accurate and reproducible results in the tensile testing of metal foils in tensile testing machines is described. Before the test specimen are placed in the machine, foil side edges are worked until they are parallel and flaw free. The specimen are also aligned between and secured to grip end members. An aligning apparatus employed in the method is comprised of an alignment box with a longitudinal bottom wall and two upright side walls, first and second removable grip end members at each end of the box, and a means for securing the grip end members within the box.
Round Robin Test of Residual Resistance Ratio of Nb$$_3$$Sn Composite Superconductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsushita, Teruo; Otabe, Edmund Soji; Kim, Dong Ho
A round robin test of residual resistance ratio (RRR) was performed for Nb 3Sn composite superconductors prepared by internal tin method by six institutes with the international standard test method described in IEC 61788-4. It was found that uncertainty mainly resulted from determination of the cryogenic resistance from the intersection of two straight lines drawn to fit the voltage vs. temperature curve around the resistive transition. As a result, the measurement clarified that RRR can be measured with expanded uncertainty not larger than 5% with the coverage factor 2 by using this test method.
CTEPP STANDARD OPERATING PROCEDURE FOR PACKING AND SHIPPING STUDY SAMPLES (SOP-3.11)
This SOP describes the methods for packing and shipping study samples. These methods are for packing and shipping biological and environmental samples. The methods have been tested and used in the previous pilot studies.
Active tower damping and pitch balancing - design, simulation and field test
NASA Astrophysics Data System (ADS)
Duckwitz, Daniel; Shan, Martin
2014-12-01
The tower is one of the major components in wind turbines with a contribution to the cost of energy of 8 to 12% [1]. In this overview the load situation of the tower will be described in terms of sources of loads, load components and fatigue contribution. Then two load reduction control schemes are described along with simulation and field test results. Pitch Balancing is described as a method to reduce aerodynamic asymmetry and the resulting fatigue loads. Active Tower Damping is reducing the tower oscillations by applying appropiate pitch angle changes. A field test was conducted on an Areva M5000 wind turbine.
METHOD OF CHEMICAL ANALYSIS FOR OIL SHALE WASTES
Several methods of chemical analysis are described for oil shale wastewaters and retort gases. These methods are designed to support the field testing of various pollution control systems. As such, emphasis has been placed on methods which are rapid and sufficiently rugged to per...
Heinänen, M; Barbas, C
2001-03-01
A method is described for ambroxol, trans-4-(2-amino-3,5-dibromobenzylamino) cyclohexanol hydrochloride, and benzoic acid separation by HPLC with UV detection at 247 nm in a syrup as pharmaceutical presentation. Optimal conditions were: Column Symmetry Shield RPC8, 5 microm 250 x 4.6 mm, and methanol/(H(3)PO(4) 8.5 mM/triethylamine pH=2.8) 40:60 v/v. Validation was performed using standards and the pharmaceutical preparation which contains the compounds described above. Results from both standards and samples show suitable validation parameters. The pharmaceutical grade substances were tested by factors that could influence the chemical stability. These reaction mixtures were analysed to evaluate the capability of the method to separate degradation products. Degradation products did not interfere with the determination of the substances tested by the assay.
Concurrent error detecting codes for arithmetic processors
NASA Technical Reports Server (NTRS)
Lim, R. S.
1979-01-01
A method of concurrent error detection for arithmetic processors is described. Low-cost residue codes with check-length l and checkbase m = 2 to the l power - 1 are described for checking arithmetic operations of addition, subtraction, multiplication, division complement, shift, and rotate. Of the three number representations, the signed-magnitude representation is preferred for residue checking. Two methods of residue generation are described: the standard method of using modulo m adders and the method of using a self-testing residue tree. A simple single-bit parity-check code is described for checking the logical operations of XOR, OR, and AND, and also the arithmetic operations of complement, shift, and rotate. For checking complement, shift, and rotate, the single-bit parity-check code is simpler to implement than the residue codes.
A comparative overview of modal testing and system identification for control of structures
NASA Technical Reports Server (NTRS)
Juang, J.-N.; Pappa, R. S.
1988-01-01
A comparative overview is presented of the disciplines of modal testing used in structural engineering and system identification used in control theory. A list of representative references from both areas is given, and the basic methods are described briefly. Recent progress on the interaction of modal testing and control disciplines is discussed. It is concluded that combined efforts of researchers in both disciplines are required for unification of modal testing and system identification methods for control of flexible structures.
Wort free amino nitrogen analysis adapted to a microplate format
USDA-ARS?s Scientific Manuscript database
The standard method for determining wort free amino nitrogen content calls for the use of test tubes and glass marbles, as well as boiling and 20°C water baths. In this paper we describe how the standard method can be updated and streamlined by replacing water baths, test tubes and marbles with a th...
An Alternative Method Of Specifying Shock Test Criteria
NASA Technical Reports Server (NTRS)
Ferebee, R. C.; Clayton, J.; Alldredge, D.; Irvine, T.
2008-01-01
Shock testing of aerospace vehicle hardware has presented many challenges over the years due to the high magnitude and short duration of the specifications. Recently, component structural failures have occurred during testing that have not manifested themselves on over 200 Space Shuttle solid rocket booster (SRB) flights (two boosters per flight). It is suspected that the method of specifying shock test criteria may be leaving important information out of the test process. The traditional test criteria specification, the shock response spectrum, can be duplicated by any number of waveforms that may not resemble the actual flight test recorded time history. One method of overcoming this limitation is described herein, which may prove useful for qualifying hardware for the upcoming Constellation Program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bauer, T. H.; Robinson, W. R.; Holland, J. W.
1989-12-01
Results and analyses of margin to cladding failure and pre-failure axial expansion of metallic fuel are reported for TREAT in-pile transient overpower tests M5--M7. These are the first such tests on reference binary and ternary alloy fuel of the Integral Fast Reactor (IFR) concept with burnup ranging from 1 to 10 at. %. In all cases, test fuel was subjected to an exponential power rise on an 8 s period until either incipient or actual cladding failure was achieved. Objectives, designs and methods are described with emphasis on developments unique to metal fuel safety testing. The resulting database for claddingmore » failure threshold and prefailure fuel expansion is presented. The nature of the observed cladding failure and resultant fuel dispersals is described. Simple models of cladding failures and pre-failure axial expansions are described and compared with experimental results. Reported results include: temperature, flow, and pressure data from test instrumentation; fuel motion diagnostic data principally from the fast neutron hodoscope; and test remains described from both destructive and non-destructive post-test examination. 24 refs., 144 figs., 17 tabs.« less
Adjusting for partial verification or workup bias in meta-analyses of diagnostic accuracy studies.
de Groot, Joris A H; Dendukuri, Nandini; Janssen, Kristel J M; Reitsma, Johannes B; Brophy, James; Joseph, Lawrence; Bossuyt, Patrick M M; Moons, Karel G M
2012-04-15
A key requirement in the design of diagnostic accuracy studies is that all study participants receive both the test under evaluation and the reference standard test. For a variety of practical and ethical reasons, sometimes only a proportion of patients receive the reference standard, which can bias the accuracy estimates. Numerous methods have been described for correcting this partial verification bias or workup bias in individual studies. In this article, the authors describe a Bayesian method for obtaining adjusted results from a diagnostic meta-analysis when partial verification or workup bias is present in a subset of the primary studies. The method corrects for verification bias without having to exclude primary studies with verification bias, thus preserving the main advantages of a meta-analysis: increased precision and better generalizability. The results of this method are compared with the existing methods for dealing with verification bias in diagnostic meta-analyses. For illustration, the authors use empirical data from a systematic review of studies of the accuracy of the immunohistochemistry test for diagnosis of human epidermal growth factor receptor 2 status in breast cancer patients.
Impact fuze testing at 3000 m/sec employing explosively accelerating plates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gill, W.
1981-01-01
The Explosives Testing Division at Sandia has developed a method of simulating a re-entry vehicle impacting the ground. The purpose of the simulation is to evaluate different fusing concepts. The design and operation of this impact testing facility are described.
Fire test method for graphite fiber reinforced plastics
NASA Technical Reports Server (NTRS)
Bowles, K. J.
1980-01-01
A potential problem in the use of graphite fiber reinforced resin matrix composites is the dispersal of graphite fibers during accidental fires. Airborne, electrically conductive fibers originating from the burning composites could enter and cause shorting in electrical equipment located in surrounding areas. A test method for assessing the burning characteristics of graphite fiber reinforced composites and the effectiveness of the composites in retaining the graphite fibers has been developed. The method utilizes a modified Ohio State University Rate of Heat Release apparatus. The equipment and the testing procedure are described. The application of the test method to the assessment of composite materials is illustrated for two resin matrix/graphite composite systems.
Simple, Low-Cost Data Collection Methods for Agricultural Field Studies.
ERIC Educational Resources Information Center
Koenig, Richard T.; Winger, Marlon; Kitchen, Boyd
2000-01-01
Summarizes relatively simple and inexpensive methods for collecting data from agricultural field studies. Describes methods involving on-farm testing, crop yield measurement, quality evaluations, weed control effectiveness, plant nutrient status, and other measures. Contains 29 references illustrating how these methods were used to conduct…
Apollo experience report environmental acceptance testing
NASA Technical Reports Server (NTRS)
Laubach, C. H. M.
1976-01-01
Environmental acceptance testing was used extensively to screen selected spacecraft hardware for workmanship defects and manufacturing flaws. The minimum acceptance levels and durations and methods for their establishment are described. Component selection and test monitoring, as well as test implementation requirements, are included. Apollo spacecraft environmental acceptance test results are summarized, and recommendations for future programs are presented.
Christopher, David; Adams, Wallace P; Lee, Douglas S; Morgan, Beth; Pan, Ziqing; Singh, Gur Jai Pal; Tsong, Yi; Lyapustina, Svetlana
2007-01-19
The purpose of this article is to present the thought process, methods, and interim results of a PQRI Working Group, which was charged with evaluating the chi-square ratio test as a potential method for determining in vitro equivalence of aerodynamic particle size distribution (APSD) profiles obtained from cascade impactor measurements. Because this test was designed with the intention of being used as a tool in regulatory review of drug applications, the capability of the test to detect differences in APSD profiles correctly and consistently was evaluated in a systematic way across a designed space of possible profiles. To establish a "base line," properties of the test in the simplest case of pairs of identical profiles were studied. Next, the test's performance was studied with pairs of profiles, where some difference was simulated in a systematic way on a single deposition site using realistic product profiles. The results obtained in these studies, which are presented in detail here, suggest that the chi-square ratio test in itself is not sufficient to determine equivalence of particle size distributions. This article, therefore, introduces the proposal to combine the chi-square ratio test with a test for impactor-sized mass based on Population Bioequivalence and describes methods for evaluating discrimination capabilities of the combined test. The approaches and results described in this article elucidate some of the capabilities and limitations of the original chi-square ratio test and provide rationale for development of additional tests capable of comparing APSD profiles of pharmaceutical aerosols.
[Computer diagnosis of traumatic impact by hepatic lesion].
Kimbar, V I; Sevankeev, V V
2007-01-01
A method of computer-assisted diagnosis of traumatic affection by liver damage (HEPAR-test program) is described. The program is based on calculated diagnostic coefficients using Bayes' probability method with Wald's recognition procedure.
Batta, Yacoub A
2016-01-01
The present article describes the technique used for preparing the invert emulsion (water-in-oil type) then, selecting the most proper formulation of invert emulsion for being used as a carrier formulation of entomopathogenic fungi. It also describes the method used for testing the efficacy of the formulated fungi as biocontrol agents of targeted insects. Detailed examples demonstrating the efficacy of formulated strains of entomopathogenic fungi against certain species of insect pests were included in the present article. The techniques and methods described in this article are reproducible and helpful in enhancing the effectiveness of formulated fungi against wide range of targeted insects in comparison with the unformulated form of these fungi. Also, these techniques and methods can be used effectively in crop protection and in the integrated pest management programs. Finally, it is important to indicate that the ingredients used for preparation of the invert emulsion have no environmental side-effects or health risks since these ingredients are safe to use and can be used in manufacturing of cosmetics or as food additives.•Description of method used for preparation of invert emulsion (water-in-oil type) and selecting the most stable and non-viscous emulsion.•Description of technique used for introducing the entomopathogenic fungi into the selected stable and non-viscous invert emulsion.•Description of method for testing the efficacy of introduced entomopathogenic fungus into the selected invert emulsion against targeted insects with detailed examples on the efficacy testing.
NASA Technical Reports Server (NTRS)
Eller, H. H.; Sugg, F. E.
1970-01-01
The methods and procedures used to perform nondestructive testing inspections of the Saturn S-2 liquid hydrogen and liquid oxygen tank weldments during fabrication and after proof testing are described to document special skills developed during the program. All post-test inspection requirements are outlined including radiographic inspections procedures.
Light airplane crash tests at impact velocities of 13 and 27 m/sec
NASA Technical Reports Server (NTRS)
Alfaro-Bou, E.; Vaughan, V. L., Jr.
1977-01-01
Two similar general aviation airplanes were crash tested at the Langley impact dynamics research facility at velocities of 13 and 27 m/sec. Other flight parameters were held constant. The facility, instrumentation, tests specimens, and test method are briefly described. Structural damage and accelerometer data are discussed.
46 CFR 164.018-11 - Approval tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...
46 CFR 164.018-11 - Approval tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...
46 CFR 164.018-11 - Approval tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...
46 CFR 164.018-11 - Approval tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...
46 CFR 164.018-11 - Approval tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the following test methods described in Federal Specification L-S-300: (1) Test conditions. (2) Test... sharp knife from each corner to the corner diagonally opposite so that an “X” is formed. The cuts must...— (1) The L-S-300 procedure for measuring reflective intensity; or (2) The procedure for measuring...
Eddy current testing for blade edge micro cracks of aircraft engine
NASA Astrophysics Data System (ADS)
Zhang, Wei-min; Xu, Min-dong; Gao, Xuan-yi; Jin, Xin; Qin, Feng
2017-10-01
Based on the problems of low detection efficiency in the micro cracks detection of aircraft engine blades, a differential excitation eddy current testing system was designed and developed. The function and the working principle of the system were described, the problems which contained the manufacture method of simulated cracks, signal generating, signal processing and the signal display method were described. The detection test was carried out by taking a certain model aircraft engine blade with simulated cracks as a tested specimen. The test data was processed by digital low-pass filter in the computer and the crack signals of time domain display and Lissajous figure display were acquired. By comparing the test results, it is verified that Lissajous figure display shows better performance compared to time domain display when the crack angle is small. The test results show that the eddy current testing system designed in this paper is feasible to detect the micro cracks on the aeroengine blade and can effectively improve the detection efficiency of micro cracks in the practical detection work.
Structural testing for static failure, flutter and other scary things
NASA Technical Reports Server (NTRS)
Ricketts, R. H.
1983-01-01
Ground test and flight test methods are described that may be used to highlight potential structural problems that occur on aircraft. Primary interest is focused on light-weight general aviation airplanes. The structural problems described include static strength failure, aileron reversal, static divergence, and flutter. An example of each of the problems is discussed to illustrate how the data acquired during the tests may be used to predict the occurrence of the structural problem. While some rules of thumb for the prediction of structural problems are given the report is not intended to be used explicitly as a structural analysis handbook.
Simultaneous real-time data collection methods
NASA Technical Reports Server (NTRS)
Klincsek, Thomas
1992-01-01
This paper describes the development of electronic test equipment which executes, supervises, and reports on various tests. This validation process uses computers to analyze test results and report conclusions. The test equipment consists of an electronics component and the data collection and reporting unit. The PC software, display screens, and real-time data-base are described. Pass-fail procedures and data replay are discussed. The OS2 operating system and Presentation Manager user interface system were used to create a highly interactive automated system. The system outputs are hardcopy printouts and MS DOS format files which may be used as input for other PC programs.
A multivariate model and statistical method for validating tree grade lumber yield equations
Donald W. Seegrist
1975-01-01
Lumber yields within lumber grades can be described by a multivariate linear model. A method for validating lumber yield prediction equations when there are several tree grades is presented. The method is based on multivariate simultaneous test procedures.
Lucijanic, Marko; Petrovecki, Mladen
2012-01-01
Analyzing events over time is often complicated by incomplete, or censored, observations. Special non-parametric statistical methods were developed to overcome difficulties in summarizing and comparing censored data. Life-table (actuarial) method and Kaplan-Meier method are described with an explanation of survival curves. For the didactic purpose authors prepared a workbook based on most widely used Kaplan-Meier method. It should help the reader understand how Kaplan-Meier method is conceptualized and how it can be used to obtain statistics and survival curves needed to completely describe a sample of patients. Log-rank test and hazard ratio are also discussed.
QCL spectroscopy combined with the least squares method for substance analysis
NASA Astrophysics Data System (ADS)
Samsonov, D. A.; Tabalina, A. S.; Fufurin, I. L.
2017-11-01
The article briefly describes distinctive features of quantum cascade lasers (QCL). It also describes an experimental set-up for acquiring mid-infrared absorption spectra using QCL. The paper demonstrates experimental results in the form of normed spectra. We tested the application of the least squares method for spectrum analysis. We used this method for substance identification and extraction of concentration data. We compare the results with more common methods of absorption spectroscopy. Eventually, we prove the feasibility of using this simple method for quantitative and qualitative analysis of experimental data acquired with QCL.
ERDA/Lewis research center photovoltaic systems test facility
NASA Technical Reports Server (NTRS)
Forestieri, A. F.; Johnson, J. A.; Knapp, W. D.; Rigo, H.; Stover, J.; Suhay, R.
1977-01-01
A national photovoltaic power systems test facility (of initial 10-kW peak power rating) is described. It consists of a solar array to generate electrical power, test-hardware for several alternate methods of power conversion, electrical energy storage systems, and an instrumentation and data acquisition system.
NASA Technical Reports Server (NTRS)
1982-01-01
The basic test methods of aging and deterioration mechanisms of electrical insulating materials are discussed. A comprehensive test system developed to study the degradation process is described. This system is completely checked, and calibrated with a few insulating material samples.
Fairchild, Amanda J.; McQuillin, Samuel D.
2017-01-01
Third variable effects elucidate the relation between two other variables, and can describe why they are related or under what conditions they are related. This article demonstrates methods to analyze two third-variable effects: moderation and mediation. The utility of examining moderation and mediation effects in school psychology is described and current use of the analyses in applied school psychology research is reviewed and evaluated. Proper statistical methods to test the effects are presented, and different effect size measures for the models are provided. Extensions of the basic moderator and mediator models are also described. PMID:20006988
Fairchild, Amanda J; McQuillin, Samuel D
2010-02-01
Third variable effects elucidate the relation between two other variables, and can describe why they are related or under what conditions they are related. This article demonstrates methods to analyze two third-variable effects: moderation and mediation. The utility of examining moderation and mediation effects in school psychology is described and current use of the analyses in applied school psychology research is reviewed and evaluated. Proper statistical methods to test the effects are presented, and different effect size measures for the models are provided. Extensions of the basic moderator and mediator models are also described.
Biodegradability Evaluation of Polymers by ISO 14855-2
Funabashi, Masahiro; Ninomiya, Fumi; Kunioka, Masao
2009-01-01
Biodegradabilities of polymers and their composites in a controlled compost were described. Polycaprolactone (PCL) and poly(lactic acid) (PLA) were employed as biodegradable polymers. Biodegradabilities of PCL and PLA samples in a controlled compost were measured using a Microbial Oxidative Degradation Analyzer (MODA) according to ISO 14855-2. Sample preparation method for biodegradation test according to ISO/DIS 10210 was also described. Effects of sizes and shapes of samples on biodegradability were studied. Reproducibility of biodegradation test of ISO 14855-2 by MODA was confirmed. Validity of sample preparation method for polymer pellets, polymer film, and polymer products of ISO/DIS 10210 for ISO 14855-2 was confirmed. PMID:20111676
Churgin, Matthew A.; He, Liping; Murray, John I.; Fang-Yen, Christopher
2014-01-01
The spatial and temporal control of transgene expression is an important tool in C. elegans biology. We previously described a method for evoking gene expression in arbitrary cells by using a focused pulsed infrared laser to induce a heat shock response (Churgin et al 2013). Here we describe detailed methods for building and testing a system for performing single-cell heat shock. Steps include setting up the laser and associated components, coupling the laser beam to a microscope, and testing heat shock protocols. All steps can be carried out using readily available off-the-shelf components. PMID:24835576
Development of a SARS Coronavirus Vaccine from Recombinant Spike Protein Plus Delta Inulin Adjuvant.
McPherson, Clifton; Chubet, Richard; Holtz, Kathy; Honda-Okubo, Yoshikazu; Barnard, Dale; Cox, Manon; Petrovsky, Nikolai
2016-01-01
Given periodic outbreaks of fatal human infections caused by coronaviruses, development of an optimal coronavirus vaccine platform capable of rapid production is an ongoing priority. This chapter describes the use of an insect cell expression system for rapid production of a recombinant vaccine against severe acute respiratory syndrome coronavirus (SARS). Detailed methods are presented for expression, purification, and release testing of SARS recombinant spike protein antigen, followed by adjuvant formulation and animal testing. The methods herein described for rapid development of a highly protective SARS vaccine are equally suited to rapid development of vaccines against other fatal human coronavirus infections, e.g., the MERS coronavirus.
RNActive® Technology: Generation and Testing of Stable and Immunogenic mRNA Vaccines.
Rauch, Susanne; Lutz, Johannes; Kowalczyk, Aleksandra; Schlake, Thomas; Heidenreich, Regina
2017-01-01
Developing effective mRNA vaccines poses certain challenges concerning mRNA stability and ability to induce sufficient immune stimulation and requires a specific panel of techniques for production and testing. Here, we describe the production of stabilized mRNA with enhanced immunogenicity, generated using conventional nucleotides only, by introducing changes to the mRNA sequence and by complexation with the nucleotide-binding peptide protamine (RNActive® technology). Methods described here include the synthesis, purification, and protamine complexation of mRNA vaccines as well as a comprehensive panel of in vitro and in vivo methods for evaluation of vaccine quality and immunogenicity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Honeycutt, M.E.; Jarvis, A.S.; McFarland, V.A.
1995-07-01
This technical note is the third in a series of three that outline and describe the principal methods that have been developed to test the potential of environmental contaminants to cause mutagenic, carcinogenic, and teratogenic effects. The first in this series (EEDP-04-24) describes methods used to discern genotoxic effects at the sub cellular level, while the second (EEDP-04-25) describes methods used to discern genotoxic effects at the cellular and organ/organism level. Recent literature citations for each topic referenced in this series of technical notes are provided in this technical note, in addition to a glossary of terms. The information inmore » these technical notes is intended to provide Corps of Engineers personnel with a working knowledge of the terminology and conceptual basis of genotoxicity testing. To develop an improved understanding of the concepts of genotoxicity, readers are encouraged to review A Primer in Genotoxicity (Jarvis, Reilly, and Lutz 1993), presented in Volume D-93-3 of the Environmental Effects of Dredging information exchange bulletin.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pope, G.A.; Sepehrnoori, K.
1992-12-31
This second annual report on innovative uses of tracers for reservoir characterization contains four sections each describing a novel use of oilfield tracers. The first section describes and illustrates the use of a new single-well tracer test to estimate wettability. This test consists of the injection of brine containing tracers followed by oil containing tracers, a shut-in period to allow some of the tracers to react, and then production of the tracers. The inclusion of the oil injection slug with tracers is unique to this test, and this is what makes the test work. We adapted our chemical simulator, UTCHEM,more » to enable us to study this tracer method and made an extensive simulation study to evaluate the effects of wettability based upon characteristic curves for relative permeability and capillary pressure for differing wetting states typical of oil reservoirs. The second section of this report describes a new method for analyzing interwell tracer data based upon a type-curve approach. Theoretical frequency response functions were used to build type curves of ``transfer function`` and ``phase spectrum`` that have dimensionless heterogeneity index as a parameter to characterize a stochastic permeability field. We illustrate this method by analyzing field tracer data. The third section of this report describes a new theory for interpreting interwell tracer data in terms of channeling and dispersive behavior for reservoirs. Once again, a stochastic approach to reservoir description is taken. The fourth section of this report describes our simulation of perfluorocarbon gas tracers. This new tracer technology developed at Brookhaven National Laboratory is being tested at the Elk Hills Naval Petroleum Reserve No. 1 in California. We report preliminary simulations made of these tracers in one of the oil reservoirs under evaluation with these tracers in this field. Our compostional simulator (UTCOMP) was used for this simulation study.« less
Tested Demonstrations. Gasoline Vapor: An Invisible Pollutant
ERIC Educational Resources Information Center
Stephens, Edgar R.
1977-01-01
Describes a demonstration concerning the air pollution aspects of gasoline vapor which provides an estimation of the vapor pressure of test fuel, the molecular weight of the vapor, and illustrates a method of controlling the pollution. (SL)
Implementation of an experimental fault-tolerant memory system
NASA Technical Reports Server (NTRS)
Carter, W. C.; Mccarthy, C. E.
1976-01-01
The experimental fault-tolerant memory system described in this paper has been designed to enable the modular addition of spares, to validate the theoretical fault-secure and self-testing properties of the translator/corrector, to provide a basis for experiments using the new testing and correction processes for recovery, and to determine the practicality of such systems. The hardware design and implementation are described, together with methods of fault insertion. The hardware/software interface, including a restricted single error correction/double error detection (SEC/DED) code, is specified. Procedures are carefully described which, (1) test for specified physical faults, (2) ensure that single error corrections are not miscorrections due to triple faults, and (3) enable recovery from double errors.
A research program to reduce interior noise in general aviation airplanes. [test methods and results
NASA Technical Reports Server (NTRS)
Roskam, J.; Muirhead, V. U.; Smith, H. W.; Peschier, T. D.; Durenberger, D.; Vandam, K.; Shu, T. C.
1977-01-01
Analytical and semi-empirical methods for determining the transmission of sound through isolated panels and predicting panel transmission loss are described. Test results presented include the influence of plate stiffness and mass and the effects of pressurization and vibration damping materials on sound transmission characteristics. Measured and predicted results are presented in tables and graphs.
Code of Federal Regulations, 2010 CFR
2010-01-01
... flammable materials by Tagliabue open-cup apparatus. 1500.43 Section 1500.43 Commercial Practices CONSUMER... materials by Tagliabue open-cup apparatus. Scope 1. (a) This method describes a test procedure for the..., that is, ignite but not continue to burn. Apparatus 3. The Tag open-cup tester is illustrated in Fig. 1...
Code of Federal Regulations, 2011 CFR
2011-01-01
... flammable materials by Tagliabue open-cup apparatus. 1500.43 Section 1500.43 Commercial Practices CONSUMER... materials by Tagliabue open-cup apparatus. Scope 1. (a) This method describes a test procedure for the..., that is, ignite but not continue to burn. Apparatus 3. The Tag open-cup tester is illustrated in Fig. 1...
Neurodevelopmental Reflex Testing in Neonatal Rat Pups.
Nguyen, Antoinette T; Armstrong, Edward A; Yager, Jerome Y
2017-04-24
Neurodevelopmental reflex testing is commonly used in clinical practice to assess the maturation of the nervous system. Neurodevelopmental reflexes are also referred to as primitive reflexes. They are sensitive and consistent with later outcomes. Abnormal reflexes are described as an absence, persistence, reappearance, or latency of reflexes, which are predictive indices of infants that are at high risk for neurodevelopmental disorders. Animal models of neurodevelopmental disabilities, such as cerebral palsy, often display aberrant developmental reflexes, as would be observed in human infants. The techniques described assess a variety of neurodevelopmental reflexes in neonatal rats. Neurodevelopmental reflex testing offers the investigator a testing method that is not otherwise available in such young animals. The methodology presented here aims to assist investigators in examining developmental milestones in neonatal rats as a method of detecting early-onset brain injury and/or determining the effectiveness of therapeutic interventions. The methodology presented here aims to provide a general guideline for investigators.
NASA Astrophysics Data System (ADS)
Pfefer, Joshua; Agrawal, Anant
2012-03-01
In recent years there has been increasing interest in development of consensus, tissue-phantom-based approaches for assessment of biophotonic imaging systems, with the primary goal of facilitating clinical translation of novel optical technologies. Well-characterized test methods based on tissue phantoms can provide useful tools for performance assessment, thus enabling standardization and device inter-comparison during preclinical development as well as quality assurance and re-calibration in the clinical setting. In this review, we study the role of phantom-based test methods as described in consensus documents such as international standards for established imaging modalities including X-ray CT, MRI and ultrasound. Specifically, we focus on three image quality characteristics - spatial resolution, spatial measurement accuracy and image uniformity - and summarize the terminology, metrics, phantom design/construction approaches and measurement/analysis procedures used to assess these characteristics. Phantom approaches described are those in routine clinical use and tend to have simplified morphology and biologically-relevant physical parameters. Finally, we discuss the potential for applying knowledge gained from existing consensus documents in the development of standardized, phantom-based test methods for optical coherence tomography.
Brown, Angus M
2010-04-01
The objective of the method described in this paper is to develop a spreadsheet template for the purpose of comparing multiple sample means. An initial analysis of variance (ANOVA) test on the data returns F--the test statistic. If F is larger than the critical F value drawn from the F distribution at the appropriate degrees of freedom, convention dictates rejection of the null hypothesis and allows subsequent multiple comparison testing to determine where the inequalities between the sample means lie. A variety of multiple comparison methods are described that return the 95% confidence intervals for differences between means using an inclusive pairwise comparison of the sample means. 2009 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Büermann, L.
2016-09-01
Materials used for the production of protective devices against diagnostic medical X-radiation described in the international standard IEC 61331-3 need to be specified in terms of their lead attenuation equivalent thickness according to the methods described in IEC 61331-1. In May 2014 the IEC published the second edition of these standards which contain improved methods for the determination of attenuation ratios and the corresponding lead attenuation equivalent thicknesses of lead-reduced or lead-free materials. These methods include the measurement of scattered photons behind the protective material which were hitherto neglected but are becoming more important because of the increasing use of lead-reduced or even lead-free materials. They can offer the same protective effect but are up to 20% lighter and also easier to dispose of. The new method is based on attenuation ratios measured with the so-called ``inverse broad beam condition''. Since the corresponding measurement procedure is new and in some respects more complex than the methods used in the past, it was regarded as being helpful to have a description of how such measurements can reliably be performed. This technical report describes in detail the attenuation ratio measurements and corresponding procedures for the lead equivalent determinations of sample materials using the method with the inverse broad beam condition as carried out at the Physikalisch-Technische Bundesanstalt (PTB). PTB still offers material testing and certification for the German responsible notified body. In addition to the description of the measurements at PTB, a short technical guide is provided for testing laboratories which intend to establish this kind of protective material certification. The guide includes technical recommendations for the testing equipment like X-ray facilities, reference lead sheets and radiation detectors; special procedures for the determination of the lead attenuation equivalent thickness; their uncertainties and the necessary contents of the test certificate.
NASA Technical Reports Server (NTRS)
Jordan, F. L., Jr.
1980-01-01
As part of basic research to improve aerial applications technology, methods were developed at the Langley Vortex Research Facility to simulate and measure deposition patterns of aerially-applied sprays and granular materials by means of tests with small-scale models of agricultural aircraft and dynamically-scaled test particles. Interactions between the aircraft wake and the dispersed particles are being studied with the objective of modifying wake characteristics and dispersal techniques to increase swath width, improve deposition pattern uniformity, and minimize drift. The particle scaling analysis, test methods for particle dispersal from the model aircraft, visualization of particle trajectories, and measurement and computer analysis of test deposition patterns are described. An experimental validation of the scaling analysis and test results that indicate improved control of chemical drift by use of winglets are presented to demonstrate test methods.
Technical and investigative support for high density digital satellite recording systems
NASA Technical Reports Server (NTRS)
Schultz, R. A.
1982-01-01
Methods and results of examinations and tests conducted on magnetic recording tapes under consideration for a high density digital (HDDR) satellite recording system are described. The examinations and tests investigate the performance of tapes with respect to their physical, magnetic and electrical characteristics. The objective of the tests, the likely significance of typical results, and the importance of the characteristics under investigation to the application are included. Theoretical discussions of measurement methods are provided where appropriate. Methods and results are discussed; the results of some sections are tabulated together to facilitate their comparison. The conclusion of each test section relates the test results to their possible significance and attempts to correlate the results of that section with the results of other tests. Some of the sections analyze sources of error inherent in the measurement methods or relate the value of the information obtained to the objectives of the test or the overall purpose of the project.
46 CFR 162.050-35 - Bilge alarm: Approval tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... water only and any zero drift must be recorded. (h) Test No. 7A Response Time Test. (1) The bilge alarm... using the method described in § 162.050-39. (b) Test No. 1A Calibration and Zero Test. (1) The bilge alarm is calibrated and zeroed to manufacturer's instructions. (2) It is then fed with water for 15...
46 CFR 162.050-35 - Bilge alarm: Approval tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... water only and any zero drift must be recorded. (h) Test No. 7A Response Time Test. (1) The bilge alarm... using the method described in § 162.050-39. (b) Test No. 1A Calibration and Zero Test. (1) The bilge alarm is calibrated and zeroed to manufacturer's instructions. (2) It is then fed with water for 15...
46 CFR 162.050-35 - Bilge alarm: Approval tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... water only and any zero drift must be recorded. (h) Test No. 7A Response Time Test. (1) The bilge alarm... using the method described in § 162.050-39. (b) Test No. 1A Calibration and Zero Test. (1) The bilge alarm is calibrated and zeroed to manufacturer's instructions. (2) It is then fed with water for 15...
29 CFR Appendix C to Subpart M of... - Personal Fall Arrest Systems
Code of Federal Regulations, 2010 CFR
2010-07-01
... with the requirements in § 1926.502(d). Paragraphs (b), (c), (d) and (e) of this Appendix describe test... Appendix D of this subpart, the test methods listed here in Appendix C can also be used to assist employers... operation. (c) Strength test. (1) During the testing of all systems, a test weight of 300 pounds plus or...
29 CFR Appendix C to Subpart M of... - Personal Fall Arrest Systems
Code of Federal Regulations, 2011 CFR
2011-07-01
... with the requirements in § 1926.502(d). Paragraphs (b), (c), (d) and (e) of this appendix describe test... appendix D of this subpart, the test methods listed here in appendix C can also be used to assist employers... operation. (c) Strength test. (1) During the testing of all systems, a test weight of 300 pounds plus or...
NASA Technical Reports Server (NTRS)
Bement, Laurence J.; Schimmel, Morry L.
1989-01-01
To overcome serious weaknesses in determining the performance of initiating devices, a novel 'ignitability test method', representing actual design interfaces and ignition materials, has been developed. Ignition device output consists of heat, light, gas an burning particles. Past research methods have evaluated these parameters individually. This paper describes the development and demonstration of an ignitability test method combining all these parameters, and the quantitative assessment of the ignition performance of two widely used percussion primers, the M42C1-PA101 and the M42C2-793. The ignition materials used for this evaluation were several powder, granule and pellet sizes of black powder and boron-potassium nitrate. This test method should be useful for performance evaluation of all initiator types, quality assurance, evaluation of ignition interfaces, and service life studies of initiators and ignition materials.
Testing Multilateral Comparisons in Africa.
ERIC Educational Resources Information Center
Bender, M. Lionel
In this paper, the multilateral comparison method of classifying languages is described and analyzed. It is suggested that while it is espoused as a simple and reasonable approach to language classification, the method has serious flaws. "Multilateral" or "mass" comparison (MC) is not a method of genetic language…
A Comparison of Three Tests of Mediation
ERIC Educational Resources Information Center
Warbasse, Rosalia E.
2009-01-01
A simulation study was conducted to evaluate the performance of three tests of mediation: the bias-corrected and accelerated bootstrap (Efron & Tibshirani, 1993), the asymmetric confidence limits test (MacKinnon, 2008), and a multiple regression approach described by Kenny, Kashy, and Bolger (1998). The evolution of these methods is reviewed and…
Automatic test comes to focal plane array production
NASA Astrophysics Data System (ADS)
Skaggs, Frank L.; Barton, T. D.
1992-08-01
To meet the needs of military and commercial markets, the infrared focal plane array industry must develop new, effective and low cost methods of fabricating and testing imaging detectors. This paper describes Texas Instruments new concepts in automated testing and cold probe technology as they apply to volume production.
New Testing Methods to Assess Technical Problem-Solving Ability.
ERIC Educational Resources Information Center
Hambleton, Ronald K.; And Others
Tests to assess problem-solving ability being provided for the Air Force are described, and some details on the development and validation of these computer-administered diagnostic achievement tests are discussed. Three measurement approaches were employed: (1) sequential problem solving; (2) context-free assessment of fundamental skills and…
40 CFR 53.3 - General requirements for an equivalent method determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature and pressure sensors, outdoor enclosure, electrical power supply, control devices and operator... rate cut-off; operation following power interruptions; effect of variations in power line voltage... other tests, full wind-tunnel tests similar to those described in § 53.62, or to special tests adapted...
An Approach to the Evaluation of Hypermedia.
ERIC Educational Resources Information Center
Knussen, Christina; And Others
1991-01-01
Discusses methods that may be applied to the evaluation of hypermedia, based on six models described by Lawton. Techniques described include observation, self-report measures, interviews, automated measures, psychometric tests, checklists and criterion-based techniques, process models, Experimentally Measuring Usability (EMU), and a naturalistic…
Four applications of permutation methods to testing a single-mediator model.
Taylor, Aaron B; MacKinnon, David P
2012-09-01
Four applications of permutation tests to the single-mediator model are described and evaluated in this study. Permutation tests work by rearranging data in many possible ways in order to estimate the sampling distribution for the test statistic. The four applications to mediation evaluated here are the permutation test of ab, the permutation joint significance test, and the noniterative and iterative permutation confidence intervals for ab. A Monte Carlo simulation study was used to compare these four tests with the four best available tests for mediation found in previous research: the joint significance test, the distribution of the product test, and the percentile and bias-corrected bootstrap tests. We compared the different methods on Type I error, power, and confidence interval coverage. The noniterative permutation confidence interval for ab was the best performer among the new methods. It successfully controlled Type I error, had power nearly as good as the most powerful existing methods, and had better coverage than any existing method. The iterative permutation confidence interval for ab had lower power than do some existing methods, but it performed better than any other method in terms of coverage. The permutation confidence interval methods are recommended when estimating a confidence interval is a primary concern. SPSS and SAS macros that estimate these confidence intervals are provided.
Method of Harmonic Balance in Full-Scale-Model Tests of Electrical Devices
NASA Astrophysics Data System (ADS)
Gorbatenko, N. I.; Lankin, A. M.; Lankin, M. V.
2017-01-01
Methods for determining the weber-ampere characteristics of electrical devices, one of which is based on solution of direct problem of harmonic balance and the other on solution of inverse problem of harmonic balance by the method of full-scale-model tests, are suggested. The mathematical model of the device is constructed using the describing function and simplex optimization methods. The presented results of experimental applications of the method show its efficiency. The advantage of the method is the possibility of application for nondestructive inspection of electrical devices in the processes of their production and operation.
7 CFR 1755.903 - Fiber optic service entrance cables.
Code of Federal Regulations, 2010 CFR
2010-01-01
... group or core designs must consist of 12 fibers or less. (3) When threads or tapes are used as core...: Cable designs must meet the requirements of Part 7, Testing and Test Methods, of ICEA S-110-717... testing. (1) The tests described in this section are intended for acceptance of cable designs and major...
7 CFR 1755.903 - Fiber optic service entrance cables.
Code of Federal Regulations, 2012 CFR
2012-01-01
... group or core designs must consist of 12 fibers or less. (3) When threads or tapes are used as core...: Cable designs must meet the requirements of Part 7, Testing and Test Methods, of ICEA S-110-717... testing. (1) The tests described in this section are intended for acceptance of cable designs and major...
7 CFR 1755.903 - Fiber optic service entrance cables.
Code of Federal Regulations, 2014 CFR
2014-01-01
... group or core designs must consist of 12 fibers or less. (3) When threads or tapes are used as core...: Cable designs must meet the requirements of Part 7, Testing and Test Methods, of ICEA S-110-717... testing. (1) The tests described in this section are intended for acceptance of cable designs and major...
7 CFR 1755.903 - Fiber optic service entrance cables.
Code of Federal Regulations, 2011 CFR
2011-01-01
... group or core designs must consist of 12 fibers or less. (3) When threads or tapes are used as core...: Cable designs must meet the requirements of Part 7, Testing and Test Methods, of ICEA S-110-717... testing. (1) The tests described in this section are intended for acceptance of cable designs and major...
7 CFR 1755.903 - Fiber optic service entrance cables.
Code of Federal Regulations, 2013 CFR
2013-01-01
... group or core designs must consist of 12 fibers or less. (3) When threads or tapes are used as core...: Cable designs must meet the requirements of Part 7, Testing and Test Methods, of ICEA S-110-717... testing. (1) The tests described in this section are intended for acceptance of cable designs and major...
Method for detecting pollutants. [through chemical reactions and heat treatment
NASA Technical Reports Server (NTRS)
Rogowski, R. S.; Richards, R. R.; Conway, E. J. (Inventor)
1976-01-01
A method is described for detecting and measuring trace amounts of pollutants of the group consisting of ozone, nitrogen dioxide, and carbon monoxide in a gaseous environment. A sample organic solid material that will undergo a chemical reaction with the test pollutant is exposed to the test environment and thereafter, when heated in the temperature range of 100-200 C., undergoes chemiluminescence that is measured and recorded as a function of concentration of the test pollutant. The chemiluminescence of the solid organic material is specific to the pollutant being tested.
Kruschke, John K; Liddell, Torrin M
2018-02-01
In the practice of data analysis, there is a conceptual distinction between hypothesis testing, on the one hand, and estimation with quantified uncertainty on the other. Among frequentists in psychology, a shift of emphasis from hypothesis testing to estimation has been dubbed "the New Statistics" (Cumming 2014). A second conceptual distinction is between frequentist methods and Bayesian methods. Our main goal in this article is to explain how Bayesian methods achieve the goals of the New Statistics better than frequentist methods. The article reviews frequentist and Bayesian approaches to hypothesis testing and to estimation with confidence or credible intervals. The article also describes Bayesian approaches to meta-analysis, randomized controlled trials, and power analysis.
A model-based test for treatment effects with probabilistic classifications.
Cavagnaro, Daniel R; Davis-Stober, Clintin P
2018-05-21
Within modern psychology, computational and statistical models play an important role in describing a wide variety of human behavior. Model selection analyses are typically used to classify individuals according to the model(s) that best describe their behavior. These classifications are inherently probabilistic, which presents challenges for performing group-level analyses, such as quantifying the effect of an experimental manipulation. We answer this challenge by presenting a method for quantifying treatment effects in terms of distributional changes in model-based (i.e., probabilistic) classifications across treatment conditions. The method uses hierarchical Bayesian mixture modeling to incorporate classification uncertainty at the individual level into the test for a treatment effect at the group level. We illustrate the method with several worked examples, including a reanalysis of the data from Kellen, Mata, and Davis-Stober (2017), and analyze its performance more generally through simulation studies. Our simulations show that the method is both more powerful and less prone to type-1 errors than Fisher's exact test when classifications are uncertain. In the special case where classifications are deterministic, we find a near-perfect power-law relationship between the Bayes factor, derived from our method, and the p value obtained from Fisher's exact test. We provide code in an online supplement that allows researchers to apply the method to their own data. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Air development update: AIR-902A
DOT National Transportation Integrated Search
2015-05-04
This document describes a practical system to determine the observer-to-aircraft closest point of approach (CPA) distance during acoustic flyby tests. The system uses a digital camera to record an image of the test aircraft. A method converting the i...
An Inexpensive System for Producing Examinations with Minimal Typing and Proofreading.
ERIC Educational Resources Information Center
Mershon, Donald H.
1982-01-01
Describes a method for increasing efficiency of examination production which uses file cards to store and organize test items. The process of reproducing tests directly from master copies made with file cards is discussed. (AM)
Filtrates & Residues: A Convenient, Low-Cost Method for Determining Sulfate in Acid Rain.
ERIC Educational Resources Information Center
Johns, Nicholas; Longstaff, Stephen J.
1987-01-01
Describes efforts in devising a method for determining sulfate quickly and accurately from rainwater samples. Explains the design and operation of the apparatus and identifies the solutions for the testing. (ML)
Recent Declines in Infant Mortality in the United States, 2005-2011
... 37 completed weeks of gestation. Data source and methods Data presented in this report were based on ... Text statements were tested for statistical significance using methods described elsewhere ( 3 ), and a statement that a ...
Fuzzy Set Methods for Object Recognition in Space Applications
NASA Technical Reports Server (NTRS)
Keller, James M. (Editor)
1992-01-01
Progress on the following four tasks is described: (1) fuzzy set based decision methodologies; (2) membership calculation; (3) clustering methods (including derivation of pose estimation parameters), and (4) acquisition of images and testing of algorithms.
The TASS Method for Scoring Production Work
ERIC Educational Resources Information Center
Orsborn, Karen J.
1977-01-01
Describes and recommends to typing teachers the Time and Speed Scoring (TASS) method for testing typewriting production and figuring production rates. This method measures speed and quality as two separate items, because proficiency in production typewriting should reflect the student's skill in typing both accurately and quickly. (MF)
Description and evaluation of an interference assessment for a slotted-wall wind tunnel
NASA Technical Reports Server (NTRS)
Kemp, William B., Jr.
1991-01-01
A wind-tunnel interference assessment method applicable to test sections with discrete finite-length wall slots is described. The method is based on high order panel method technology and uses mixed boundary conditions to satisfy both the tunnel geometry and wall pressure distributions measured in the slotted-wall region. Both the test model and its sting support system are represented by distributed singularities. The method yields interference corrections to the model test data as well as surveys through the interference field at arbitrary locations. These results include the equivalent of tunnel Mach calibration, longitudinal pressure gradient, tunnel flow angularity, wall interference, and an inviscid form of sting interference. Alternative results which omit the direct contribution of the sting are also produced. The method was applied to the National Transonic Facility at NASA Langley Research Center for both tunnel calibration tests and tests of two models of subsonic transport configurations.
Further evaluation of traditional icing scaling methods
NASA Technical Reports Server (NTRS)
Anderson, David N.
1996-01-01
This report provides additional evaluations of two methods to scale icing test conditions; it also describes a hybrid technique for use when scaled conditions are outside the operating envelope of the test facility. The first evaluation is of the Olsen method which can be used to scale the liquid-water content in icing tests, and the second is the AEDC (Ruff) method which is used when the test model is less than full size. Equations for both scaling methods are presented in the paper, and the methods were evaluated by performing icing tests in the NASA Lewis Icing Research Tunnel (IRT). The Olsen method was tested using 53 cm diameter NACA 0012 airfoils. Tests covered liquid-water-contents which varied by as much as a factor of 1.8. The Olsen method was generally effective in giving scale ice shapes which matched the reference shapes for these tests. The AEDC method was tested with NACA 0012 airfoils with chords from 18 cm to 53 cm. The 53 cm chord airfoils were used in reference tests, and 1/2 and 1/3 scale tests were made at conditions determined by applying the AEDC scaling method. The scale and reference airspeeds were matched in these tests. The AEDC method was found to provide fairly effective scaling for 1/2 size tests, but for 1/3 size models, scaling was generally less effective. In addition to these two scaling methods, a hybrid approach was also tested in which the Olsen method was used to adjust the LWC after size was scaled using the constant Weber number method. This approach was found to be an effective way to test when scaled conditions would otherwise be outside the capability of the test facility.
A Model Based Security Testing Method for Protocol Implementation
Fu, Yu Long; Xin, Xiao Long
2014-01-01
The security of protocol implementation is important and hard to be verified. Since the penetration testing is usually based on the experience of the security tester and the specific protocol specifications, a formal and automatic verification method is always required. In this paper, we propose an extended model of IOLTS to describe the legal roles and intruders of security protocol implementations, and then combine them together to generate the suitable test cases to verify the security of protocol implementation. PMID:25105163
Kanamori, Hajime; Rutala, William A; Gergen, Maria F; Sickbert-Bennett, Emily E; Weber, David J
2018-05-07
Susceptibility to germicides for carbapenem/colistin-resistant Enterobacteriaceae is poorly described. We investigated the efficacy of multiple germicides against these emerging antibiotic-resistant pathogens using the disc-based quantitative carrier test method that can produce results more similar to those encountered in healthcare settings than a suspension test. Our study results demonstrated that germicides commonly used in healthcare facilities likely will be effective against carbapenem/colistin-resistant Enterobacteriaceae when used appropriately in healthcare facilities. Copyright © 2018 American Society for Microbiology.
A model based security testing method for protocol implementation.
Fu, Yu Long; Xin, Xiao Long
2014-01-01
The security of protocol implementation is important and hard to be verified. Since the penetration testing is usually based on the experience of the security tester and the specific protocol specifications, a formal and automatic verification method is always required. In this paper, we propose an extended model of IOLTS to describe the legal roles and intruders of security protocol implementations, and then combine them together to generate the suitable test cases to verify the security of protocol implementation.
2.1 meter (82 inch) Slip Ring By-Pass Project
NASA Astrophysics Data System (ADS)
Bryan, Corby B.
2006-12-01
2.1 meter (82 inch) Slip Ring By-Pass Project I will describe a project to bypass the old method of getting control communications above the rotation point of the McDonald Observatory 2.1 meter dome. The old method used slip rings that were implemented in the late 1930s. The new system uses wireless serial commands which allow the control lines to be taken off the slip rings, leaving only power and ground. I will describe how the concept was devised so the slip rings could be by-passed, what micro-controller system that was decided on and used, how the wireless units were set up and finally how the system was tested and put in place with only limited tasks to control. (I.E. the opening and closing of the shutters) We describe the advantages to making this upgrade and how it could benefit any telescope interested in upgrading its communication systems. This project was designed and tested in ten weeks during the McDonald Observatory REU and was supported under NSF AST-0243745. The system was designed so that it could be installed while running side by side with the current method of getting control to the above rotation point. The method is still in place being tested on the 2.1 meter telescope and will soon be fully implemented by the University of Texas McDonald Observatory OS staff.
Implementation of an improved adaptive-implicit method in a thermal compositional simulator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tan, T.B.
1988-11-01
A multicomponent thermal simulator with an adaptive-implicit-method (AIM) formulation/inexact-adaptive-Newton (IAN) method is presented. The final coefficient matrix retains the original banded structure so that conventional iterative methods can be used. Various methods for selection of the eliminated unknowns are tested. AIM/IAN method has a lower work count per Newtonian iteration than fully implicit methods, but a wrong choice of unknowns will result in excessive Newtonian iterations. For the problems tested, the residual-error method described in the paper for selecting implicit unknowns, together with the IAN method, had an improvement of up to 28% of the CPU time over the fullymore » implicit method.« less
Test methods for environment-assisted cracking
NASA Astrophysics Data System (ADS)
Turnbull, A.
1992-03-01
The test methods for assessing environment assisted cracking of metals in aqueous solution are described. The advantages and disadvantages are examined and the interrelationship between results from different test methods is discussed. The source of differences in susceptibility to cracking occasionally observed from the varied mechanical test methods arises often from the variation between environmental parameters in the different test conditions and the lack of adequate specification, monitoring, and control of environmental variables. Time is also a significant factor when comparing results from short term tests with long exposure tests. In addition to these factors, the intrinsic difference in the important mechanical variables, such as strain rate, associated with the various mechanical tests methods can change the apparent sensitivity of the material to stress corrosion cracking. The increasing economic pressure for more accelerated testing is in conflict with the characteristic time dependence of corrosion processes. Unreliable results may be inevitable in some cases but improved understanding of mechanisms and the development of mechanistically based models of environment assisted cracking which incorporate the key mechanical, material, and environmental variables can provide the framework for a more realistic interpretation of short term data.
Extension of moment projection method to the fragmentation process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Shaohua; Yapp, Edward K.Y.; Akroyd, Jethro
2017-04-15
The method of moments is a simple but efficient method of solving the population balance equation which describes particle dynamics. Recently, the moment projection method (MPM) was proposed and validated for particle inception, coagulation, growth and, more importantly, shrinkage; here the method is extended to include the fragmentation process. The performance of MPM is tested for 13 different test cases for different fragmentation kernels, fragment distribution functions and initial conditions. Comparisons are made with the quadrature method of moments (QMOM), hybrid method of moments (HMOM) and a high-precision stochastic solution calculated using the established direct simulation algorithm (DSA) and advantagesmore » of MPM are drawn.« less
A modified Elek test for detection of toxigenic corynebacteria in the diagnostic laboratory.
Engler, K H; Glushkevich, T; Mazurova, I K; George, R C; Efstratiou, A
1997-02-01
The detection of toxigenicity among Corynebacterium diphtheriae and Corynebacterium ulcerans strains is the most important test for the microbiological diagnosis of diphtheria. Difficulties with current methods, in particular the Elek test, are well documented. We therefore describe a modified Elek test which provides an accurate result after only 16 h of incubation, in contrast to 48 h for the conventional test.
ERIC Educational Resources Information Center
Shahnazari-Dorcheh, Mohammadtaghi; Roshan, Saeed
2012-01-01
Due to the lack of span test for the use in language-specific and cross-language studies, this study provides L1 and L2 researchers with a reliable language-independent span test (math span test) for the measurement of working memory capacity. It also describes the development, validation, and scoring method of this test. This test included 70…
The SIETTE Automatic Assessment Environment
ERIC Educational Resources Information Center
Conejo, Ricardo; Guzmán, Eduardo; Trella, Monica
2016-01-01
This article describes the evolution and current state of the domain-independent Siette assessment environment. Siette supports different assessment methods--including classical test theory, item response theory, and computer adaptive testing--and integrates them with multidimensional student models used by intelligent educational systems.…
Training Manuals and Technical Publications.
ERIC Educational Resources Information Center
Army Test and Evaluation Command, Aberdeen Proving Ground, MD.
The objective of the Materiel Test Procedure is to describe methods for determining the need for adequacy of comprehensiveness, and clarity of training manuals and technical publications (or other pertinent types of literature) relating to the ammunition or ammunition components being tested. (Author)
How to Do It. Using the Allium Test to Detect Environmental Pollutants.
ERIC Educational Resources Information Center
Kendler, Barry S.; Koritz, Helen G.
1990-01-01
Described is a simple test which uses micro- and macro-observations of onion root tips to demonstrate mutagenic and other toxic effects of various contaminants. Discussed are materials, methods, microscopic procedures, and applications of this activity. (CW)
Software Quality Assurance and Verification for the MPACT Library Generation Process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yuxuan; Williams, Mark L.; Wiarda, Dorothea
This report fulfills the requirements for the Consortium for the Advanced Simulation of Light-Water Reactors (CASL) milestone L2:RTM.P14.02, “SQA and Verification for MPACT Library Generation,” by documenting the current status of the software quality, verification, and acceptance testing of nuclear data libraries for MPACT. It provides a brief overview of the library generation process, from general-purpose evaluated nuclear data files (ENDF/B) to a problem-dependent cross section library for modeling of light-water reactors (LWRs). The software quality assurance (SQA) programs associated with each of the software used to generate the nuclear data libraries are discussed; specific tests within the SCALE/AMPX andmore » VERA/XSTools repositories are described. The methods and associated tests to verify the quality of the library during the generation process are described in detail. The library generation process has been automated to a degree to (1) ensure that it can be run without user intervention and (2) to ensure that the library can be reproduced. Finally, the acceptance testing process that will be performed by representatives from the Radiation Transport Methods (RTM) Focus Area prior to the production library’s release is described in detail.« less
Molecular diagnostics for human leptospirosis.
Waggoner, Jesse J; Pinsky, Benjamin A
2016-10-01
The definitive diagnosis of leptospirosis, which results from infection with spirochetes of the genus Leptospira, currently relies on the use of culture, serological testing (microscopic agglutination testing), and molecular detection. The purpose of this review is to describe new molecular diagnostics for Leptospira and discuss advancements in the use of available methods. Efforts have been focused on improving the clinical sensitivity of Leptospira detection using molecular methods. In this review, we describe a reoptimized pathogenic species-specific real-time PCR (targeting lipL32) that has demonstrated improved sensitivity, findings by two groups that real-time reverse-transcription PCR assays targeting the 16S rrs gene can improve detection, and two new loop-mediated amplification techniques. Quantitation of leptospiremia, detection in different specimen types, and the complementary roles played by molecular detection and microscopic agglutination testing will be discussed. Finally, a protocol for Leptospira strain subtyping using variable number tandem repeat targets and high-resolution melting will be described. Molecular diagnostics have an established role for the diagnosis of leptospirosis and provide an actionable diagnosis in the acute setting. The use of real-time reverse-transcription PCR for testing serum/plasma and cerebrospinal fluid, when available, may improve the detection of Leptospira without decreasing clinical specificity.
Sixty-five years since the New York heat wave: advances in sweat testing for cystic fibrosis.
Collie, Jake T B; Massie, R John; Jones, Oliver A H; LeGrys, Vicky A; Greaves, Ronda F
2014-02-01
The sweat test remains important as a diagnostic test for cystic fibrosis (CF) and has contributed greatly to our understanding of CF as a disease of epithelial electrolyte transport. The standardization of the sweat test, by Gibson and Cooke [Gibson and Cooke (1959) Pediatrics 1959;23:5], followed observations of excessive dehydration amongst patients with CF and confirmed the utility as a diagnostic test. Quantitative pilocarpine iontophoresis remains the gold standard for sweat induction, but there are a number of collection and analytical methods. The pathophysiology of electrolyte transport in sweat was described by Quinton [Quinton (1983) Nature 1983;301:421-422], and this complemented the developments in genetics that discovered the cystic fibrosis transmembrane conductance regulator (CFTR), an epithelial-based electrolyte transport protein. Knowledge of CF has since increased rapidly and further developments in sweat testing include: new collection methods, further standardization of the technique with international recommendations and age related reference intervals. More recently, sweat chloride values have been used as proof of effect for the new drugs that activate CFTR. However, there remain issues with adherence to sweat test guidelines in many countries and there are gaps in our knowledge, including reference intervals for some age groups and stability of sweat samples in transport. Furthermore, modern methods of elemental quantification need to be explored as alternatives to the original analytical methods for sweat electrolyte measurement. The purpose of this review is therefore to describe the development of the sweat test and consider future directions. © 2013 Wiley Periodicals, Inc.
The Identification of Software Failure Regions
1990-06-01
be used to detect non-obviously redundant test cases. A preliminary examination of the manual analysis method is performed with a set of programs ...failure regions are defined and a method of failure region analysis is described in detail. The thesis describes how this analysis may be used to detect...is the termination of the ability of a functional unit to perform its required function. (Glossary, 1983) The presence of faults in program code
Wodushek, Thomas R; Greher, Michael R
2017-05-01
In the first column in this 2-part series, Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review, the authors introduced performance validity tests (PVTs) and their function, provided a justification for why they are necessary, traced their ongoing endorsement by neuropsychological organizations, and described how they are used and interpreted by ever increasing numbers of clinical neuropsychologists. To enhance readers' understanding of these measures, this second column briefly describes common detection strategies used in PVTs as well as the typical methods used to validate new PVTs and determine cut scores for valid/invalid determinations. We provide a discussion of the latest research demonstrating how neuropsychologists can combine multiple PVTs in a single battery to improve sensitivity/specificity to invalid responding. Finally, we discuss future directions for the research and application of PVTs.
Design and Validation of a Straight-Copy Typewriting Prognostic Test Using Kinesthetic Sensitivity.
ERIC Educational Resources Information Center
Olson, Norma Jean
1979-01-01
Describes the development and application of a kinesthetic sensitivity test to determine whether it is a valid and reliable measure of straight-copy typing speed and accuracy. The author states that this kinesthetic sensitivity instrument may be used as a prognostic aptitude test and recommends administration methods. (MF)
Techniques employed by the NASA White Sands Test Facility to ensure oxygen system component safety
NASA Technical Reports Server (NTRS)
Stradling, J. S.; Pippen, D. L.; Frye, G. W.
1983-01-01
Methods of ascertaining the safety and suitability of a variety of oxygen system components are discussed. Additionally, qualification and batch control requirements for soft goods in oxygen systems are presented. Current oxygen system component qualification test activities in progress at White Sands Test Facility are described.
A Guide to Computer Adaptive Testing Systems
ERIC Educational Resources Information Center
Davey, Tim
2011-01-01
Some brand names are used generically to describe an entire class of products that perform the same function. "Kleenex," "Xerox," "Thermos," and "Band-Aid" are good examples. The term "computerized adaptive testing" (CAT) is similar in that it is often applied uniformly across a diverse family of testing methods. Although the various members of…
A New Nonparametric Levene Test for Equal Variances
ERIC Educational Resources Information Center
Nordstokke, David W.; Zumbo, Bruno D.
2010-01-01
Tests of the equality of variances are sometimes used on their own to compare variability across groups of experimental or non-experimental conditions but they are most often used alongside other methods to support assumptions made about variances. A new nonparametric test of equality of variances is described and compared to current "gold…
Specific Yields Estimated from Gravity Change during Pumping Test
NASA Astrophysics Data System (ADS)
Chen, K. H.; Hwang, C.; Chang, L. C.
2017-12-01
Specific yield (Sy) is the most important parameter to describe available groundwater capacity in an unconfined aquifer. When estimating Sy by a field pumping test, aquifer heterogeneity and well performers will cause a large uncertainty. In this study, we use a gravity-based method to estimate Sy. At the time of pumping test, amounts of mass (groundwater) are forced to be taken out. If drawdown corn is big and close enough to high precision gravimeter, the gravity change can be detected. The gravity-based method use gravity observations that are independent from traditional flow computation. Only the drawdown corn should be modeled with observed head and hydrogeology data. The gravity method can be used in most groundwater field tests, such as locally pumping/injection tests initiated by active man-made or annual variations due to natural sources. We apply our gravity method at few sites in Taiwan situated over different unconfined aquifer. Here pumping tests for Sy determinations were also carried out. We will discuss why the gravity method produces different results from traditional pumping test, field designs and limitations of the gravity method.
Integration of optical measurement methods with flight parameter measurement systems
NASA Astrophysics Data System (ADS)
Kopecki, Grzegorz; Rzucidlo, Pawel
2016-05-01
During the AIM (advanced in-flight measurement techniques) and AIM2 projects, innovative modern techniques were developed. The purpose of the AIM project was to develop optical measurement techniques dedicated for flight tests. Such methods give information about aircraft elements deformation, thermal loads or pressure distribution, etc. In AIM2 the development of optical methods for flight testing was continued. In particular, this project aimed at the development of methods that could be easily applied in flight tests in an industrial setting. Another equally important task was to guarantee the synchronization of the classical measuring system with cameras. The PW-6U glider used in flight tests was provided by the Rzeszów University of Technology. The glider had all the equipment necessary for testing the IPCT (image pattern correlation technique) and IRT (infrared thermometry) methods. Additionally, equipment adequate for the measurement of typical flight parameters, registration and analysis has been developed. This article describes the designed system, as well as presenting the system’s application during flight tests. Additionally, the results obtained in flight tests show certain limitations of the IRT method as applied.
Operational experience from LCLS-II cryomodule testing
NASA Astrophysics Data System (ADS)
Wang, R.; Hansen, B.; White, M.; Hurd, J.; Atassi, O. Al; Bossert, R.; Pei, L.; Klebaner, A.; Makara, J.; Theilacker, J.; Kaluzny, J.; Wu, G.; Harms, E.
2017-12-01
This paper describes the initial operational experience gained from testing Linac Coherent Light Source II (LCLS-II) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). Strategies for a controlled slow cooldown to 100 K and a fast cooldown past the niobium superconducting transition temperature of 9.2 K will be described. The test stand for the cryomodules at CMTF is sloped to match gradient in the LCLS-II tunnel at Stanford Linear Accelerator (SLAC) laboratory, which adds an additional challenge to stable liquid level control. Control valve regulation, Superconducting Radio-Frequency (SRF) power compensation, and other methods of stabilizing liquid level and pressure in the cryomodule 2.0 K SRF cavity circuit will be discussed. Several different pumping configurations using cold compressors and warm vacuum pumps have been used on the cryomodule 2.0 K return line and the associated results will be described.
An Index and Test of Linear Moderated Mediation.
Hayes, Andrew F
2015-01-01
I describe a test of linear moderated mediation in path analysis based on an interval estimate of the parameter of a function linking the indirect effect to values of a moderator-a parameter that I call the index of moderated mediation. This test can be used for models that integrate moderation and mediation in which the relationship between the indirect effect and the moderator is estimated as linear, including many of the models described by Edwards and Lambert ( 2007 ) and Preacher, Rucker, and Hayes ( 2007 ) as well as extensions of these models to processes involving multiple mediators operating in parallel or in serial. Generalization of the method to latent variable models is straightforward. Three empirical examples describe the computation of the index and the test, and its implementation is illustrated using Mplus and the PROCESS macro for SPSS and SAS.
Test and evaluation procedures for Sandia's Teraflops Operating System (TOS) on Janus.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnette, Daniel Wayne
This report describes the test and evaluation methods by which the Teraflops Operating System, or TOS, that resides on Sandia's massively-parallel computer Janus is verified for production release. Also discussed are methods used to build TOS before testing and evaluating, miscellaneous utility scripts, a sample test plan, and a proposed post-test method for quickly examining the large number of test results. The purpose of the report is threefold: (1) to provide a guide to T&E procedures, (2) to aid and guide others who will run T&E procedures on the new ASCI Red Storm machine, and (3) to document some ofmore » the history of evaluation and testing of TOS. This report is not intended to serve as an exhaustive manual for testers to conduct T&E procedures.« less
Probabilistic numerical methods for PDE-constrained Bayesian inverse problems
NASA Astrophysics Data System (ADS)
Cockayne, Jon; Oates, Chris; Sullivan, Tim; Girolami, Mark
2017-06-01
This paper develops meshless methods for probabilistically describing discretisation error in the numerical solution of partial differential equations. This construction enables the solution of Bayesian inverse problems while accounting for the impact of the discretisation of the forward problem. In particular, this drives statistical inferences to be more conservative in the presence of significant solver error. Theoretical results are presented describing rates of convergence for the posteriors in both the forward and inverse problems. This method is tested on a challenging inverse problem with a nonlinear forward model.
ERIC Educational Resources Information Center
Waninge, A.; Evenhuis, I. J.; van Wijck, R.; van der Schans, C. P.
2011-01-01
Background: The purpose of this study is to describe feasibility and test-retest reliability of the six-minute walking distance test (6MWD) and an adapted shuttle run test (aSRT) in persons with severe intellectual and sensory (multiple) disabilities. Materials and Methods: Forty-seven persons with severe multiple disabilities, with Gross Motor…
Results of continuous synchronous orbit testing of sealed nickel-cadmium cells
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1981-01-01
Test results from continuous synchronous orbit testing of sealed nickel cadmium cells are presented. The synchronous orbit regime simulates a space satellite maintaining a position over a fixed point on earth as the earth rotates on its axis and revolves about the sun. Characteristics of each lot of cells, test conditions, and charge control methods are described.
Infra-red lamp panel study and assessment application to thermal vacuum testing of sigma telescope
NASA Technical Reports Server (NTRS)
Mauduyt, Jacques; Merlet, Joseph; Poux, Christiane
1986-01-01
A research and development program of the Infra-Red Test has been conducted by the French Space Agency (CNES). A choice, after characterization, among several possibilities has been made on the type of methods and facilities for the I.R. test. An application to the Thermal Vacuum Test of the SIGMA Telescope is described.
Properties of an adaptive feedback equalization algorithm.
Engebretson, A M; French-St George, M
1993-01-01
This paper describes a new approach to feedback equalization for hearing aids. The method involves the use of an adaptive algorithm that estimates and tracks the characteristic of the hearing aid feedback path. The algorithm is described and the results of simulation studies and bench testing are presented.
Sakai, Shinobu; Adachi, Reiko; Akiyama, Hiroshi; Teshima, Reiko
2013-06-19
A labeling system for food allergenic ingredients was established in Japan in April 2002. To monitor the labeling, the Japanese government announced official methods for detecting allergens in processed foods in November 2002. The official methods consist of quantitative screening tests using enzyme-linked immunosorbent assays (ELISAs) and qualitative confirmation tests using Western blotting or polymerase chain reactions (PCR). In addition, the Japanese government designated 10 μg protein/g food (the corresponding allergenic ingredient soluble protein weight/food weight), determined by ELISA, as the labeling threshold. To standardize the official methods, the criteria for the validation protocol were described in the official guidelines. This paper, which was presented at the Advances in Food Allergen Detection Symposium, ACS National Meeting and Expo, San Diego, CA, Spring 2012, describes the validation protocol outlined in the official Japanese guidelines, the results of interlaboratory studies for the quantitative detection method (ELISA for crustacean proteins) and the qualitative detection method (PCR for shrimp and crab DNAs), and the reliability of the detection methods.
Lee, Min Wook; An, Seongpil; Yoon, Sam S; Yarin, Alexander L
2018-02-01
Here, we review the state-of-the-art in the field of engineered self-healing materials. These materials mimic the functionalities of various natural materials found in the human body (e.g., the healing of skin and bones by the vascular system). The fabrication methods used to produce these "vascular-system-like" engineered self-healing materials, such as electrospinning (including co-electrospinning and emulsion spinning) and solution blowing (including coaxial solution blowing and emulsion blowing) are discussed in detail. Further, a few other approaches involving the use of hollow fibers are also described. In addition, various currently used healing materials/agents, such as dicyclopentadiene and Grubbs' catalyst, poly(dimethyl siloxane), and bisphenol-A-based epoxy, are described. We also review the characterization methods employed to verify the physical and chemical aspects of self-healing, that is, the methods used to confirm that the healing agent has been released and that it has resulted in healing, as well as the morphological changes induced in the damaged material by the healing agent. These characterization methods include different visualization and spectroscopy techniques and thermal analysis methods. Special attention is paid to the characterization of the mechanical consequences of self-healing. The effects of self-healing on the mechanical properties such as stiffness and adhesion of the damaged material are evaluated using the tensile test, double cantilever beam test, plane strip test, bending test, and adhesion test (e.g., blister test). Finally, the future direction of the development of these systems is discussed. Copyright © 2017 Elsevier B.V. All rights reserved.
Confidence limit calculation for antidotal potency ratio derived from lethal dose 50
Manage, Ananda; Petrikovics, Ilona
2013-01-01
AIM: To describe confidence interval calculation for antidotal potency ratios using bootstrap method. METHODS: We can easily adapt the nonparametric bootstrap method which was invented by Efron to construct confidence intervals in such situations like this. The bootstrap method is a resampling method in which the bootstrap samples are obtained by resampling from the original sample. RESULTS: The described confidence interval calculation using bootstrap method does not require the sampling distribution antidotal potency ratio. This can serve as a substantial help for toxicologists, who are directed to employ the Dixon up-and-down method with the application of lower number of animals to determine lethal dose 50 values for characterizing the investigated toxic molecules and eventually for characterizing the antidotal protections by the test antidotal systems. CONCLUSION: The described method can serve as a useful tool in various other applications. Simplicity of the method makes it easier to do the calculation using most of the programming software packages. PMID:25237618
Delay test generation for synchronous sequential circuits
NASA Astrophysics Data System (ADS)
Devadas, Srinivas
1989-05-01
We address the problem of generating tests for delay faults in non-scan synchronous sequential circuits. Delay test generation for sequential circuits is a considerably more difficult problem than delay testing of combinational circuits and has received much less attention. In this paper, we present a method for generating test sequences to detect delay faults in sequential circuits using the stuck-at fault sequential test generator STALLION. The method is complete in that it will generate a delay test sequence for a targeted fault given sufficient CPU time, if such a sequence exists. We term faults for which no delay test sequence exists, under out test methodology, sequentially delay redundant. We describe means of eliminating sequential delay redundancies in logic circuits. We present a partial-scan methodology for enhancing the testability of difficult-to-test of untestable sequential circuits, wherein a small number of flip-flops are selected and made controllable/observable. The selection process guarantees the elimination of all sequential delay redundancies. We show that an intimate relationship exists between state assignment and delay testability of a sequential machine. We describe a state assignment algorithm for the synthesis of sequential machines with maximal delay fault testability. Preliminary experimental results using the test generation, partial-scan and synthesis algorithm are presented.
NASA Technical Reports Server (NTRS)
Lawing, P. L.
1985-01-01
A method of constructing airfoils by inscribing pressure channels on the face of opposing plates, bonding them together to form one plate with integral channels, and contour machining this plate to form an airfoil model is described. The research and development program to develop the bonding technology is described as well as the construction and testing of an airfoil model. Sample aerodynamic data sets are presented and discussed. Also, work currently under way to produce thin airfoils with camber is presented. Samples of the aft section of a 6 percent airfoil with complete pressure instrumentation including the trailing edge are pictured and described. This technique is particularly useful in fabricating models for transonic cryogenic testing, but it should find application in a wide ange of model construction projects, as well as the fabrication of fuel injectors, space hardware, and other applications requiring advanced bonding technology and intricate fluid passages.
Liu, Yuewei; Chen, Weihong
2012-02-01
As a nonparametric method, the Kruskal-Wallis test is widely used to compare three or more independent groups when an ordinal or interval level of data is available, especially when the assumptions of analysis of variance (ANOVA) are not met. If the Kruskal-Wallis statistic is statistically significant, Nemenyi test is an alternative method for further pairwise multiple comparisons to locate the source of significance. Unfortunately, most popular statistical packages do not integrate the Nemenyi test, which is not easy to be calculated by hand. We described the theory and applications of the Kruskal-Wallis and Nemenyi tests, and presented a flexible SAS macro to implement the two tests. The SAS macro was demonstrated by two examples from our cohort study in occupational epidemiology. It provides a useful tool for SAS users to test the differences among three or more independent groups using a nonparametric method.
Ervin, S L
1999-01-01
Member retention has been a challenge for Medicare HMOs. This article describes how a hybrid Medicare HMO is testing methods of strengthening member loyalty and member retention. Methods include managing member expectations and involving sales representatives and Personal Care Planner in outreach to new members. An early problem detection project yielded information that was used to resolve member difficulties and preempt disenrollment.
Advanced Gas Turbine (AGT) powertrain system
NASA Technical Reports Server (NTRS)
Helms, H. E.; Kaufeld, J.; Kordes, R.
1981-01-01
A 74.5 kW(100 hp) advanced automotive gas turbine engine is described. A design iteration to improve the weight and production cost associated with the original concept is discussed. Major rig tests included 15 hours of compressor testing to 80% design speed and the results are presented. Approximately 150 hours of cold flow testing showed duct loss to be less than the design goal. Combustor test results are presented for initial checkout tests. Turbine design and rig fabrication is discussed. From a materials study of six methods to fabricate rotors, two have been selected for further effort. A discussion of all six methods is given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eppich, J.D.; Hecklinger, R.S.
1995-11-01
This paper by Roger S. Hecklinger is a good contribution to the understanding of municipal solid waste combustion. The traditional test methods used on residue testing were summarized in a clear manner. Mr. Hecklinger describes sampling problems using coal and coke ash testing methods, which are similar to those experienced in testing the solid waste itself for its fuel content. The author gives several comments regarding the importance of the sampling program. This article also contains the original author`s reply to the comments and questions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruiz, Steven Adriel
The following discussion contains a high-level description of methods used to implement software for data processing. It describes the required directory structures and file handling required to use Excel's Visual Basic for Applications programming language and how to identify shot, test and capture types to appropriately process data. It also describes how to interface with the software.
40 CFR 60.714 - Installation of monitoring devices and recordkeeping.
Code of Federal Regulations, 2013 CFR
2013-07-01
... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...
40 CFR 60.714 - Installation of monitoring devices and recordkeeping.
Code of Federal Regulations, 2014 CFR
2014-07-01
... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...
40 CFR 60.714 - Installation of monitoring devices and recordkeeping.
Code of Federal Regulations, 2012 CFR
2012-07-01
... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...
40 CFR 60.714 - Installation of monitoring devices and recordkeeping.
Code of Federal Regulations, 2010 CFR
2010-07-01
... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...
40 CFR 60.714 - Installation of monitoring devices and recordkeeping.
Code of Federal Regulations, 2011 CFR
2011-07-01
... by the test method described in § 60.713(b)(1) (liquid material balance) shall maintain records of... equipment controlled by a carbon adsorption system and demonstrating compliance by the procedures described..., as appropriate. (1) For carbon adsorption systems with a common exhaust stack for all the individual...
Some Experiments with Respiratory Deficient Mutants of Yeast (Saccharomyces cerevisiae)
ERIC Educational Resources Information Center
Freeland, P. W.
1978-01-01
Methods are described for the induction and identification of respiratory deficient mutants in yeast. Practical schemes are given to enable students to obtain dose-response information for physical and chemical mutagens such as heat, ultraviolet light, or acriflavine. A simple test for environmental mutagens is described. (Author/MA)
NASA Technical Reports Server (NTRS)
Hozman, Aron D.; Hughes, William O.
2014-01-01
It is important to realize that some test-articles may have significant sound absorption that may challenge the acoustic power capabilities of a test facility. Therefore, to mitigate this risk of not being able to meet the customers target spectrum, it is prudent to demonstrate early-on an increased acoustic power capability which compensates for this test-article absorption. This paper describes a concise method to reduce this risk when testing aerospace test-articles which have significant absorption. This method was successfully applied during the SpaceX Falcon 9 Payload Fairing acoustic test program at the NASA Glenn Research Center Plum Brook Stations RATF.
Correcting for deformation in skin-based marker systems.
Alexander, E J; Andriacchi, T P
2001-03-01
A new technique is described that reduces error due to skin movement artifact in the opto-electronic measurement of in vivo skeletal motion. This work builds on a previously described point cluster technique marker set and estimation algorithm by extending the transformation equations to the general deformation case using a set of activity-dependent deformation models. Skin deformation during activities of daily living are modeled as consisting of a functional form defined over the observation interval (the deformation model) plus additive noise (modeling error). The method is described as an interval deformation technique. The method was tested using simulation trials with systematic and random components of deformation error introduced into marker position vectors. The technique was found to substantially outperform methods that require rigid-body assumptions. The method was tested in vivo on a patient fitted with an external fixation device (Ilizarov). Simultaneous measurements from markers placed on the Ilizarov device (fixed to bone) were compared to measurements derived from skin-based markers. The interval deformation technique reduced the errors in limb segment pose estimate by 33 and 25% compared to the classic rigid-body technique for position and orientation, respectively. This newly developed method has demonstrated that by accounting for the changing shape of the limb segment, a substantial improvement in the estimates of in vivo skeletal movement can be achieved.
Electrochemical sensor/detector system and method
Glass, Robert S.; Perone, Sam P.; Ciarlo, Dino R.; Kimmons, James F.
1992-01-01
An electrochemical detection system is described comprising in combination: (a) a multielement, microelectrode array detector containing means for acquiring a plurality of signals; (b) electronic means for receiving said signals and converting said signals into a readout or display providing information with respect to the nature and concentration of elements present in a solution being tested. Also described is the means of making the above described microelectrode detector.
Electrochemical sensor/detector system and method
Glass, Robert S.; Perone, Sam P.; Ciarlo, Dino R.; Kimmons, James F.
1994-01-01
An electrochemical detection system is described comprising in combination: (a) a multielement, microelectrode array detector containing means for acquiring a plurality of signals; (b) electronic means for receiving said signals and converting said signals into a readout or display providing information with respect to the nature and concentration of elements present in a solution being tested. Also described is the means of making the above described microelectrode detector.
Reconstruction of multiple cracks from experimental electrostatic boundary measurements
NASA Technical Reports Server (NTRS)
Bryan, Kurt; Liepa, Valdis; Vogelius, Michael
1993-01-01
An algorithm for recovering a collection of linear cracks in a homogeneous electrical conductor from boundary measurements of voltages induced by specified current fluxes is described. The technique is a variation of Newton's method and is based on taking weighted averages of the boundary data. An apparatus that was constructed specifically for generating laboratory data on which to test the algorithm is also described. The algorithm is applied to a number of different test cases and the results are discussed.
Apollo-Soyuz test project docking system
NASA Technical Reports Server (NTRS)
Swan, W. L., Jr.
1976-01-01
The United States and Soviet Union in July 1975 successfully completed a joint space mission utilizing each country's spacecraft and the compatible docking system designed and fabricated by each country. The compatible docking system is described, along with the extensive research, development, and testing leading up to the successful mission. It also describes the formulation and implementation of methods for breaking the language barrier, bridging the extensive distances for communication and travel, and adjusting to each country's different culture during the three-year development program.
Akram, A J; Ireland, A J; Postlethwaite, K C; Sandy, J R; Jerreat, A S
2013-11-01
This article describes the process of validity and reliability testing of a condition-specific quality-of-life measure for patients with hypodontia presenting for orthodontic treatment. The development of the instrument is described in a previous article. Royal Devon and Exeter NHS Foundation Trust & Musgrove Park Hospital, Taunton. The child perception questionnaire was used as a standard against which to test criterion validity. The Bland and Altman method was used to check agreement between the two questionnaires. Construct validity was tested using principal component analysis on the four sections of the questionnaire. Test-retest reliability was tested using intraclass correlation coefficient and Bland and Altman method. Cronbach's alpha was used to test internal consistency reliability. Overall the questionnaire showed good reliability, criterion and construct validity. This together with previous evidence of good face and content validity suggests that the instrument may prove useful in clinical practice and further research. This study has demonstrated that the newly developed condition-specific quality-of-life questionnaire is both valid and reliable for use in young patients with hypodontia. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
SHAW, Anugrah; COLEONE-CARVALHO, Ana Carla; HOLLINGSHURST, Julien; DRAPER, Michael; MACHADO NETO, Joaquim Gonçalves
2017-01-01
A collaborative approach, involving resources and expertise from several countries, was used to develop a test cell to measure cumulative permeation by a solid-state collection technique. The new technique was developed to measure the permeation of pesticide active ingredients and other chemicals with low vapor pressure that would otherwise be difficult to test via standard techniques. The development process is described and the results from the final chosen test method are reported. Inter-laboratory studies were conducted to further refine the new method and determine repeatability and reliability. The revised test method has been approved as a new ISO/EN standard to measure permeation of chemicals with low vapor pressure and/or solubility in water. PMID:29033403
This paper describes the method and test results of the engine dyno portion of the benchmarking test results including engine fuel consumption maps showing the effects of cylinder deactivation engine technology.
21 CFR 352.77 - Test modifications.
Code of Federal Regulations, 2010 CFR
2010-04-01
... modification of the testing procedures in this subpart. In addition, alternative methods (including automated or in vitro procedures) employing the same basic procedures as those described in this subpart may be used. Any proposed modification or alternative procedure shall be submitted as a petition in accord...
21 CFR 352.77 - Test modifications.
Code of Federal Regulations, 2011 CFR
2011-04-01
... modification of the testing procedures in this subpart. In addition, alternative methods (including automated or in vitro procedures) employing the same basic procedures as those described in this subpart may be used. Any proposed modification or alternative procedure shall be submitted as a petition in accord...
Experiences with digital processing of images at INPE
NASA Technical Reports Server (NTRS)
Mascarenhas, N. D. A. (Principal Investigator)
1984-01-01
Four different research experiments with digital image processing at INPE will be described: (1) edge detection by hypothesis testing; (2) image interpolation by finite impulse response filters; (3) spatial feature extraction methods in multispectral classification; and (4) translational image registration by sequential tests of hypotheses.
Preventing Boredom in the Language Laboratory
ERIC Educational Resources Information Center
Obanya, Pai
1978-01-01
An experimental year of oral testing using the language laboratory at Victoria University is described. A new first-year 12-credit course is primarily a language course based on audiovisual/lingual methods. The content, evaluation, and administration of oral expression tests and performance tapes are covered. (SW)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-03
... Fuel Elements for Use in Research and Test Reactors AGENCY: Nuclear Regulatory Commission. ACTION... Research and Test Reactors.'' This guide describes a method that the staff of the NRC considers acceptable... assurance program for verifying the quality of plate-type uranium-aluminum fuel elements used in research...
R. & D. in Psychometrics: Technical Reports on Latent Structure Models.
ERIC Educational Resources Information Center
Wilcox, Rand R.
This document contains three papers from the Methodology Project of the Center for the Study of Evaluation. Methods for characterizing test accuracy are reported in the first two papers. "Bounds on the K Out of N Reliability of a Test, and an Exact Test for Hierarchically Related Items" describes and illustrates how an extension of a…
ERIC Educational Resources Information Center
Feldt, Leonard S.
2004-01-01
In some settings, the validity of a battery composite or a test score is enhanced by weighting some parts or items more heavily than others in the total score. This article describes methods of estimating the total score reliability coefficient when differential weights are used with items or parts.
Integration of QSAR and in vitro toxicology.
Barratt, M D
1998-01-01
The principles of quantitative structure-activity relationships (QSAR) are based on the premise that the properties of a chemical are implicit in its molecular structure. Therefore, if a mechanistic hypothesis can be proposed linking a group of related chemicals with a particular toxic end point, the hypothesis can be used to define relevant parameters to establish a QSAR. Ways in which QSAR and in vitro toxicology can complement each other in development of alternatives to live animal experiments are described and illustrated by examples from acute toxicological end points. Integration of QSAR and in vitro methods is examined in the context of assessing mechanistic competence and improving the design of in vitro assays and the development of prediction models. The nature of biological variability is explored together with its implications for the selection of sets of chemicals for test development, optimization, and validation. Methods are described to support the use of data from in vivo tests that do not meet today's stringent requirements of acceptability. Integration of QSAR and in vitro methods into strategic approaches for the replacement, reduction, and refinement of the use of animals is described with examples. PMID:9599692
A novel rheometer design for yield stress fluids
Joseph R. Samaniuk; Timothy W. Shay; Thatcher W. Root; Daniel J. Klingenberg; C. Tim Scott
2014-01-01
An inexpensive, rapid method for measuring the rheological properties of yield stress fluids is described and tested. The method uses an auger that does not rotate during measurements, and avoids material and instrument-related difficulties, for example, wall slip and the presence of large particles, associated with yield stress fluids. The method can be used...
The Analysis of Discourse as Evaluation of Productive Thinking.
ERIC Educational Resources Information Center
Tripp, D. H.
This paper provides a thorough description of a method of analyzing and scoring group discussions from a particular point of view. After discussing shortcomings of traditional methods of reporting data from group discussions and problems inherent in the use of paper-and-pencil creativity tests, the author describes a method which was developed as…
THe Case Method of Instruction (CMI) Project. Final Report.
ERIC Educational Resources Information Center
McWilliam, P. J.; And Others
This final report describes the Case Method of Instruction (CMI) Project, a project to develop, field test, and disseminate training materials to facilitate the use of the Case Method of Instruction by inservice and preservice instructors in developmental disabilities. CMI project activities focused on developing a collection of case stories and…
Turbulence excited frequency domain damping measurement and truncation effects
NASA Technical Reports Server (NTRS)
Soovere, J.
1976-01-01
Existing frequency domain modal frequency and damping analysis methods are discussed. The effects of truncation in the Laplace and Fourier transform data analysis methods are described. Methods for eliminating truncation errors from measured damping are presented. Implications of truncation effects in fast Fourier transform analysis are discussed. Limited comparison with test data is presented.
Fathead minnows are used as a model fish species for the characterization of the endocrine-disrupting potential of environmental contaminants. This research describes the development of a PCR method that can determine the genetic sex in this species. This method, when incorpora...
40 CFR Appendix A-3 to Part 60 - Test Methods 4 through 5I
Code of Federal Regulations, 2011 CFR
2011-07-01
... isokinetic sampling rates prior to a pollutant emission measurement run. The approximation method described... with a pollutant emission measurement run. When it is, calculation of percent isokinetic, pollutant emission rate, etc., for the run shall be based upon the results of the reference method or its equivalent...
ESEA Title I Linking Project. Final Report.
ERIC Educational Resources Information Center
Holmes, Susan E.
The Rasch model for test score equating was compared with three other equating procedures as methods for implementing the norm referenced method (RMC Model A) of evaluating ESEA Title I projects. The Rasch model and its theoretical limitations were described. The three other equating methods used were: linear observed score equating, linear true…
Operational Experience from LCLS-II Cryomodule Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Renzhuo; Hansen, Benjamin; White, Michael
This paper describes the initial operational experience gained from testing Linac Coherent Light Source II (LCLS-II) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). Strategies for a controlled slow cooldown to 100 K and a fast cooldown past the niobium superconducting transition temperature of 9.2 K will be described. The test stand for the cryomodules at CMTF is sloped to match gradient in the LCLS-II tunnel at Stanford Linear Accelerator (SLAC) laboratory, which adds an additional challenge to stable liquid level control. Control valve regulation, Superconducting Radio-Frequency (SRF) power compensation, and other methods of stabilizing liquid level and pressure in themore » cryomodule 2.0 K SRF cavity circuit will be discussed. Several different pumping configurations using cold compressors and warm vacuum pumps have been used on the cryomodule 2.0 K return line and the associated results will be described.« less
Development of a test protocol for evaluating EVA glove performance
NASA Technical Reports Server (NTRS)
Hinman, Elaine M.
1992-01-01
Testing gloved hand performance involves work from several disciplines. Evaluations performed in the course of reenabling a disabled hand, designing a robotic end effector or master controller, or hard-suit design have all yielded relevant information, and, in most cases, produced performance test methods. Most times, these test methods have been primarily oriented toward their parent discipline. For space operations, a comparative test which would provide a way to quantify pressure glove and end effector performance would be useful in dividing tasks between humans and robots. Such a test would have to rely heavily on sensored measurement, as opposed to questionnaires, to produce relevant data. However, at some point human preference would have to be taken into account. This paper presents a methodology for evaluating gloved hand performance which attempts to respond to these issues. Glove testing of a prototype glove design using this method is described.
U 3Si 2 Fabrication and Testing for Implementation into the BISON Fuel Performance Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knight, Travis W.
A creep test stand was designed and constructed for compressive creep testing of U 3Si 2 pellets. This is described in Chapter 3. Creep testing of U 3Si 2 pellets was completed. In total, 13 compressive creep tests of U 3Si 2 pellets was successfully completed. This is reported in Chapter 3. Secondary creep model of U 3Si 2 was developed and implemented in BISON. This is described in Chapter 4. Properties of U 3Si 2 were implemented in BISON. This is described in Chapter 4. A resonant frequency and damping analyzer (RFDA) using impulse excitation technique (IET) was setup,more » tested, and used to analyze U 3Si 2 samples to measure Young’s and Shear Moduli which were then used to calculate the Poisson ratio for U 3Si 2. This is described in Chapter 5. Characterization of U 3Si 2 samples was completed. Samples were prepared and analyzed by XRD, SEM, and optical microscopy. Grain size analysis was conducted on images. SEM with EDS was used to analyze second phase precipitates. Impulse excitation technique was used to determine the Young’s and Shear Moduli of a tile specimen which allowed for the determination of the Poisson ratio. Helium pycnometry and mercury intrusion porosimetry was performed and used with image analysis to determine porosity size distribution. Vickers microindentation characterization method was used to evaluate the mechanical properties of U 3Si 2 including toughness, hardness, and Vickers hardness. Electrical resistivity measurement was done using the four-point probe method. This is reported in Chapter 5.« less
Coal-cleaning plant refuse characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cavalet, J.R.; Torak, E.R.
1985-06-01
This report describes a study performed for the Electric Power Research Institute's Coal Cleaning Test Facility in Homer City, Pennsylvania. The purpose of the study was to design a standard methods for chemically and physically classifying refuse generated by physical coal cleaning and to construct a matrix that will accurately predict how a particular refuse will react to particular disposal methods - based solely on raw-coal characteristics and the process used to clean the coal. The value of such a classification system (which has not existed to this point) is the ability to design efficient and economical systems for disposingmore » of specific coal cleaning refuse. The report describes the project's literature search and a four-tier classification system. It also provides designs for test piles, sampling procedures, and guidelines for a series of experiments to test the classfication system and create an accurate, reliable predictive matrix. 38 refs., 39 figs., 35 tabs.« less
Numerical Modeling of Flow Distribution in Micro-Fluidics Systems
NASA Technical Reports Server (NTRS)
Majumdar, Alok; Cole, Helen; Chen, C. P.
2005-01-01
This paper describes an application of a general purpose computer program, GFSSP (Generalized Fluid System Simulation Program) for calculating flow distribution in a network of micro-channels. GFSSP employs a finite volume formulation of mass and momentum conservation equations in a network consisting of nodes and branches. Mass conservation equation is solved for pressures at the nodes while the momentum conservation equation is solved at the branches to calculate flowrate. The system of equations describing the fluid network is solved by a numerical method that is a combination of the Newton-Raphson and successive substitution methods. The numerical results have been compared with test data and detailed CFD (computational Fluid Dynamics) calculations. The agreement between test data and predictions is satisfactory. The discrepancies between the predictions and test data can be attributed to the frictional correlation which does not include the effect of surface tension or electro-kinetic effect.
Imaging indicator for ESD safety testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whinnery, LeRoy L.,; Nissen, April; Keifer, Patrick N.
2013-05-01
This report describes the development of a new detection method for electrostatic discharge (ESD) testing of explosives, using a single-lens reflex (SLR) digital camera and a 200-mm macro lens. This method has demonstrated several distinct advantages to other current ESD detection methods, including the creation of a permanent record, an enlarged image for real-time viewing as well as extended periods of review, and ability to combine with most other Go/No-Go sensors. This report includes details of the method, including camera settings and position, and results with wellcharacterized explosives PETN and RDX, and two ESD-sensitive aluminum powders.
New Approaches in Force-Limited Vibration Testing of Flight Hardware
NASA Technical Reports Server (NTRS)
Kolaini, Ali R.; Kern, Dennis L.
2012-01-01
To qualify flight hardware for random vibration environments the following methods are used to limit the loads in the aerospace industry: (1) Response limiting and notching (2) Simple TDOF model (3) Semi-empirical force limits (4) Apparent mass, etc. and (5) Impedance method. In all these methods attempts are made to remove conservatism due to the mismatch in impedances between the test and the flight configurations of the hardware that are being qualified. Assumption is the hardware interfaces have correlated responses. A new method that takes into account the un-correlated hardware interface responses are described in this presentation.
Software Engineering Laboratory (SEL) Ada performance study report
NASA Technical Reports Server (NTRS)
Booth, Eric W.; Stark, Michael E.
1991-01-01
The goals of the Ada Performance Study are described. The methods used are explained. Guidelines for future Ada development efforts are given. The goals and scope of the study are detailed, and the background of Ada development in the Flight Dynamics Division (FDD) is presented. The organization and overall purpose of each test are discussed. The purpose, methods, and results of each test and analyses of these results are given. Guidelines for future development efforts based on the analysis of results from this study are provided. The approach used on the performance tests is discussed.
NASA Technical Reports Server (NTRS)
Antonille, Scott R.; Miskey, Cherie L.; Ohl, Raymond G.; Rohrbach, Scott O.; Aronstein, David L.; Bartoszyk, Andrew E.; Bowers, Charles W.; Cofie, Emmanuel; Collins, Nicholas R.; Comber, Brian J.;
2016-01-01
NASA's James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (40K). The JWST Observatory includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) that contains four science instruments (SI) and the fine guider. The SIs are mounted to a composite metering structure. The SI and guider units were integrated to the ISIM structure and optically tested at the NASA Goddard Space Flight Center as a suite using the Optical Telescope Element SIMulator (OSIM). OSIM is a full field, cryogenic JWST telescope simulator. SI performance, including alignment and wave front error, were evaluated using OSIM. We describe test and analysis methods for optical performance verification of the ISIM Element, with an emphasis on the processes used to plan and execute the test. The complexity of ISIM and OSIM drove us to develop a software tool for test planning that allows for configuration control of observations, associated scripts, and management of hardware and software limits and constraints, as well as tools for rapid data evaluation, and flexible re-planning in response to the unexpected. As examples of our test and analysis approach, we discuss how factors such as the ground test thermal environment are compensated in alignment. We describe how these innovative methods for test planning and execution and post-test analysis were instrumental in the verification program for the ISIM element, with enough information to allow the reader to consider these innovations and lessons learned in this successful effort in their future testing for other programs.
NASA Astrophysics Data System (ADS)
Antonille, Scott R.; Miskey, Cherie L.; Ohl, Raymond G.; Rohrbach, Scott O.; Aronstein, David L.; Bartoszyk, Andrew E.; Bowers, Charles W.; Cofie, Emmanuel; Collins, Nicholas R.; Comber, Brian J.; Eichhorn, William L.; Glasse, Alistair C.; Gracey, Renee; Hartig, George F.; Howard, Joseph M.; Kelly, Douglas M.; Kimble, Randy A.; Kirk, Jeffrey R.; Kubalak, David A.; Landsman, Wayne B.; Lindler, Don J.; Malumuth, Eliot M.; Maszkiewicz, Michael; Rieke, Marcia J.; Rowlands, Neil; Sabatke, Derek S.; Smith, Corbett T.; Smith, J. Scott; Sullivan, Joseph F.; Telfer, Randal C.; Te Plate, Maurice; Vila, M. Begoña.; Warner, Gerry D.; Wright, David; Wright, Raymond H.; Zhou, Julia; Zielinski, Thomas P.
2016-09-01
NASA's James Webb Space Telescope (JWST) is a 6.5m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM), that contains four science instruments (SI) and the Fine Guidance Sensor (FGS). The SIs are mounted to a composite metering structure. The SIs and FGS were integrated to the ISIM structure and optically tested at NASA's Goddard Space Flight Center using the Optical Telescope Element SIMulator (OSIM). OSIM is a full-field, cryogenic JWST telescope simulator. SI performance, including alignment and wavefront error, was evaluated using OSIM. We describe test and analysis methods for optical performance verification of the ISIM Element, with an emphasis on the processes used to plan and execute the test. The complexity of ISIM and OSIM drove us to develop a software tool for test planning that allows for configuration control of observations, implementation of associated scripts, and management of hardware and software limits and constraints, as well as tools for rapid data evaluation, and flexible re-planning in response to the unexpected. As examples of our test and analysis approach, we discuss how factors such as the ground test thermal environment are compensated in alignment. We describe how these innovative methods for test planning and execution and post-test analysis were instrumental in the verification program for the ISIM element, with enough information to allow the reader to consider these innovations and lessons learned in this successful effort in their future testing for other programs.
NASA Technical Reports Server (NTRS)
Ferebee, Robert N.
1992-01-01
An environmental application using a microtiter culture assay to measure the metabolic sensitivity of microorganisms to petrochemical effluents will be tested. The Biomedical Operations and Research Branch at NASA JSC has recently developed a rapid and nondestructive method to measure cell growth and metabolism. Using a colorimetric procedure the uniquely modified assay allows the metabolic kinetics of prokaryotic and eukaryotic cells to be measured. Use of such an assay if adapted for the routine monitoring of waste products, process effluents, and environmentally hazardous substances may prove to be invaluable to the industrial community. The microtiter method as described will be tested using microorganisms isolated from the Galveston Bay aquatic habitat. The microbial isolates will be identified prior to testing using the automated systems available at JSC. Sodium dodecyl sulfate (SDS), cadmium, and lead will provide control toxic chemicals. The toxicity of industrial effluent from two industrial sites will be tested. An effort will be made to test the efficacy of this assay for measuring toxicity in a mixed culture community.
A comparison of diagnostic tests for lactose malabsorption - which one is the best?
2009-01-01
Background Perceived milk intolerance is a common complaint, and tests for lactose malabsorption (LM) are unreliable. This study assesses the agreement between diagnostic tests for LM and describes the diagnostic properties of the tests. Methods Patients above 18 years of age with suspected LM were included. After oral intake of 25 g lactose, a combined test with measurement of serum glucose (s-glucose) and hydrogen (H2) and methane (CH4) in expired air was performed and symptoms were recorded. In patients with discrepancies between the results, the combined test was repeated and a gene test for lactose non-persistence was added. The diagnosis of LM was based on an evaluation of all tests. The following tests were compared: Increase in H2, CH4, H2+CH4 and H2+CH4x2 in expired air, increase in s-glucose, and symptoms. The agreement was calculated and the diagnostic properties described. Results Sixty patients were included, seven (12%) had LM. The agreement (kappa-values) between the methods varied from 0.25 to 0.91. The best test was the lactose breath test with measurement of the increase in H2 + CH4x2 in expired air. With a cut-off level < 18 ppm, the area under the ROC-curve was 0.967 and sensitivity was 100%. This shows that measurement of CH4 in addition to H2 improves the diagnostic properties of the breath test. Conclusion The agreement between commonly used methods for the diagnosis of LM was unsatisfactory. A lactose breath test with measurement of H2 + CH4x2 in expired air had the best diagnostic properties. PMID:19878587
Validation of Milliflex® Quantum for Bioburden Testing of Pharmaceutical Products.
Gordon, Oliver; Goverde, Marcel; Staerk, Alexandra; Roesti, David
2017-01-01
This article reports the validation strategy used to demonstrate that the Milliflex ® Quantum yielded non-inferior results to the traditional bioburden method. It was validated according to USP <1223>, European Pharmacopoeia 5.1.6, and Parenteral Drug Association Technical Report No. 33 and comprised the validation parameters robustness, ruggedness, repeatability, specificity, limit of detection and quantification, accuracy, precision, linearity, range, and equivalence in routine operation. For the validation, a combination of pharmacopeial ATCC strains as well as a broad selection of in-house isolates were used. In-house isolates were used in stressed state. Results were statistically evaluated regarding the pharmacopeial acceptance criterion of ≥70% recovery compared to the traditional method. Post-hoc test power calculations verified the appropriateness of the used sample size to detect such a difference. Furthermore, equivalence tests verified non-inferiority of the rapid method as compared to the traditional method. In conclusion, the rapid bioburden on basis of the Milliflex ® Quantum was successfully validated as alternative method to the traditional bioburden test. LAY ABSTRACT: Pharmaceutical drug products must fulfill specified quality criteria regarding their microbial content in order to ensure patient safety. Drugs that are delivered into the body via injection, infusion, or implantation must be sterile (i.e., devoid of living microorganisms). Bioburden testing measures the levels of microbes present in the bulk solution of a drug before sterilization, and thus it provides important information for manufacturing a safe product. In general, bioburden testing has to be performed using the methods described in the pharmacopoeias (membrane filtration or plate count). These methods are well established and validated regarding their effectiveness; however, the incubation time required to visually identify microbial colonies is long. Thus, alternative methods that detect microbial contamination faster will improve control over the manufacturing process and speed up product release. Before alternative methods may be used, they must undergo a side-by-side comparison with pharmacopeial methods. In this comparison, referred to as validation, it must be shown in a statistically verified manner that the effectiveness of the alternative method is at least equivalent to that of the pharmacopeial methods. Here we describe the successful validation of an alternative bioburden testing method based on fluorescent staining of growing microorganisms applying the Milliflex ® Quantum system by MilliporeSigma. © PDA, Inc. 2017.
40 CFR 455.50 - Identification of test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... methods cited and described in Table IG at 40 CFR 136.3(a). Pesticide manufacturers may not use the analytical method cited in Table IB, Table IC, or Table ID of 40 CFR 136.3(a) to make these determinations (except where the method cited in those tables is identical to the method specified in Table IG at 40 CFR...
A Comparison of Methods to Analyze Aquatic Heterotrophic Flagellates of Different Taxonomic Groups.
Jeuck, Alexandra; Nitsche, Frank; Wylezich, Claudia; Wirth, Olaf; Bergfeld, Tanja; Brutscher, Fabienne; Hennemann, Melanie; Monir, Shahla; Scherwaß, Anja; Troll, Nicole; Arndt, Hartmut
2017-08-01
Heterotrophic flagellates contribute significantly to the matter flux in aquatic and terrestrial ecosystems. Still today their quantification and taxonomic classification bear several problems in field studies, though these methodological problems seem to be increasingly ignored in current ecological studies. Here we describe and test different methods, the live-counting technique, different fixation techniques, cultivation methods like the liquid aliquot method (LAM), and a molecular single cell survey called aliquot PCR (aPCR). All these methods have been tested either using aquatic field samples or cultures of freshwater and marine taxa. Each of the described methods has its advantages and disadvantages, which have to be considered in every single case. With the live-counting technique a detection of living cells up to morphospecies level is possible. Fixation of cells and staining methods are advantageous due to the possible long-term storage and observation of samples. Cultivation methods (LAM) offer the possibility of subsequent molecular analyses, and aPCR tools might complete the deficiency of LAM in terms of the missing detection of non-cultivable flagellates. In summary, we propose a combination of several investigation techniques reducing the gap between the different methodological problems. Copyright © 2017 Elsevier GmbH. All rights reserved.
Exponential integrators in time-dependent density-functional calculations
NASA Astrophysics Data System (ADS)
Kidd, Daniel; Covington, Cody; Varga, Kálmán
2017-12-01
The integrating factor and exponential time differencing methods are implemented and tested for solving the time-dependent Kohn-Sham equations. Popular time propagation methods used in physics, as well as other robust numerical approaches, are compared to these exponential integrator methods in order to judge the relative merit of the computational schemes. We determine an improvement in accuracy of multiple orders of magnitude when describing dynamics driven primarily by a nonlinear potential. For cases of dynamics driven by a time-dependent external potential, the accuracy of the exponential integrator methods are less enhanced but still match or outperform the best of the conventional methods tested.
NASA Technical Reports Server (NTRS)
Roth, J. P.
1972-01-01
Methods for development of logic design together with algorithms for failure testing, a method for design of logic for ultra-large-scale integration, extension of quantum calculus to describe the functional behavior of a mechanism component-by-component and to computer tests for failures in the mechanism using the diagnosis algorithm, and the development of an algorithm for the multi-output 2-level minimization problem are discussed.
NASA Technical Reports Server (NTRS)
Majumdar, Alok; Schallhorn, Paul
1998-01-01
This paper describes a finite volume computational thermo-fluid dynamics method to solve for Navier-Stokes equations in conjunction with energy equation and thermodynamic equation of state in an unstructured coordinate system. The system of equations have been solved by a simultaneous Newton-Raphson method and compared with several benchmark solutions. Excellent agreements have been obtained in each case and the method has been found to be significantly faster than conventional Computational Fluid Dynamic(CFD) methods and therefore has the potential for implementation in Multi-Disciplinary analysis and design optimization in fluid and thermal systems. The paper also describes an algorithm of design optimization based on Newton-Raphson method which has been recently tested in a turbomachinery application.
Vital-Durand, F
1996-01-01
Acuity cards are being more commonly used in clinical and screening practice. The author describes his experience from over 6000 infants tested with the method, using two commercially available sets of cards to provide users with comprehensive guidelines to allow them to get the most out of this useful test.
How to test herbicides at forest tree nurseries.
Roger E. Sandquist; Peyton W. Owston; Stephen E. McDonald
1981-01-01
Procedures developed in a cooperative westwide study of weed control in forest tree nurseries are described in a form modified for use by nursery managers. The proven, properly designed test and evaluation methods can be used to generate data needed for evaluation and registration of herbicides.
Going to the 'Dogs' to Test Hypotheses.
ERIC Educational Resources Information Center
Kramm, Kenneth R.
1982-01-01
Describes an alternative method for using live animals in the classroom. A toy dog, the "Trail Tracker Hound Dog" (manufactured by CPG Products Corporation, Cincinnati, Ohio), is used to encourage development of such skills as observation, hypothesis testing, and collection and analysis of scientific data. (Author/JN)
Exploring Chlamydia Positivity among Females on College Campuses, 2008-2010
ERIC Educational Resources Information Center
Habel, Melissa A.; Leichliter, Jami S.; Torrone, Elizabeth
2016-01-01
Objective: Describe chlamydia positivity among young women tested at college health centers by student characteristics: age, race/ethnicity, and institution type. Participants: During 2008-2010, colleges participating in a national infertility prevention program provided chlamydia testing data from females aged 18-24. Methods: Chlamydia positivity…
Women’s perspectives of the fetal fibronectin testing process: a qualitative descriptive study
2014-01-01
Background In 2009 the Ontario Ministry of Health and Long Term Care funded the implementation of province-wide fetal fibronectin testing in Ontario hospitals. This paper reports results from the provincial evaluation that sought to describe the experience of fetal fibronectin testing from the perspective of women with symptoms of preterm labour. Methods A descriptive qualitative design was used, employing semi-structured telephone and face-to-face interviews with women who had fetal fibronectin testing. Results Five hospitals participated in recruiting women for the study and 17 women were interviewed. Women described their experiences of fetal fibronectin testing as an emotional process that moves from expecting, to feeling, to hoping for reassurance; and then to re-defining what is required to feel reassured. Women described feeling anxious while waiting for fetal fibronectin results. When test results were negative, women described feeling a sense of relief that their symptoms would not likely lead to an imminent preterm birth. Women with positive results expressed feeling reassured by the care decisions and quick action taken by the health care team. Conclusion Fetal fibronectin testing was acceptable and beneficial to these women with symptoms of preterm labour. Implications for practice and future research are suggested. PMID:24894630
Development of EPA`s new methods to quantify vector attraction of wastewater sludges
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farrell, J.B.; Bhide, V.; Smith, J.E. Jr.
1996-05-01
EPA`s 1979 and 1993 sludge regulations require that sewage sludge be reduced in vector attraction before it can be applied to the land. In the 1979 regulation, satisfactory vector attraction reduction (VAR) could be demonstrated if treatment processes reduced the volatile solids content of sludge by 38%. The 1993 regulation adds two alternative test methods for aerobic sludges for determining whether VAR has been adequate. In the first method, specific oxygen uptake rate (SOUR) of the sludge must be <1.5 mg O{sub 2}/hr/g total solids, and in the second method, the additional volatile solids reduction (AVSR) that occurs when themore » sludge is further digested for 30 days must be <15%. Experimentation with the new tests is described. Comparisons among the three methods showed that the 38% VSR requirement and the SOUR test were equivalent only near 20{degree}C. The AVSR test was more conservative than either of the other tests. 18 refs., 7 figs., 3 tabs.« less
Large-mirror testing facility at the National Optical Astronomy Observatories.
NASA Astrophysics Data System (ADS)
Barr, L. D.; Coudé du Foresto, V.; Fox, J.; Poczulp, G. A.; Richardson, J.; Roddier, C.; Roddier, F.
1991-09-01
A method for testing the surfaces of large mirrors has been developed to be used even when conditions of vibration and thermal turbulence in the light path cannot be eliminated. The full aperture of the mirror under test is examined by means of a scatterplate interferometer that has the property of being a quasi-common-path method, although any means for obtaining interference fringes will do. The method uses a remotely operated CCD camera system to record the fringe pattern from the workpiece. The typical test is done with a camera exposure of about a millisecond to "freeze" the fringe pattern on the detector. Averaging up to 10 separate exposures effectively eliminates the turbulence effects. The method described provides the optician with complete numerical information and visual plots for the surface under test and the diffracted image the method will produce, all within a few minutes, to an accuracy of 0.01 μm measured peak-to-valley.
Analytical method for establishing indentation rolling resistance
NASA Astrophysics Data System (ADS)
Gładysiewicz, Lech; Konieczna, Martyna
2018-01-01
Belt conveyors are highly reliable machines able to work in special operating conditions. Harsh environment, long distance of transporting and great mass of transported martials are cause of high energy usage. That is why research in the field of belt conveyor transportation nowadays focuses on reducing the power consumption without lowering their efficiency. In this paper, previous methods for testing rolling resistance are described, and new method designed by authors was presented. New method of testing rolling resistance is quite simple and inexpensive. Moreover it allows to conduct the experimental tests of the impact of different parameters on the value of indentation rolling resistance such as core design, cover thickness, ambient temperature, idler travel frequency, or load value as well. Finally results of tests of relationship between rolling resistance and idler travel frequency and between rolling resistance and idler travel speed was presented.
A comparison of in vitro cytotoxicity assays in medical device regulatory studies.
Liu, Xuemei; Rodeheaver, Denise P; White, Jeffrey C; Wright, Ann M; Walker, Lisa M; Zhang, Fan; Shannon, Stephen
2018-06-06
Medical device biocompatibility testing is used to evaluate the risk of adverse effects on tissues from exposure to leachates/extracts. A battery of tests is typically recommended in accordance with regulatory standards to determine if the device is biocompatible. In vitro cytotoxicity, a key element of the standards, is a required endpoint for all types of medical devices. Each validated cytotoxicity method has different methodology and acceptance criteria that could influence the selection of a specific test. In addition, some guidances are more specific than others as to the recommended test methods. For example, the International Organization for Standardization (ISO 1 ) cites preference for quantitative methods (e.g., tetrazolium (MTT/XTT), neutral red (NR), or colony formation assays (CFA)) over qualitative methods (e.g., elution, agar overlay/diffusion, or direct), while a recent ISO standard for contact lens/lens care solutions specifically requires a qualitative direct test. Qualitative methods are described in United States Pharmacopeia (USP) while quantitative CFAs are listed in Japan guidance. The aim of this review is to compare the methodologies such as test article preparation, test conditions, and criteria for six cytotoxicity methods recommended in regulatory standards in order to inform decisions on which method(s) to select during the medical device safety evaluation. Copyright © 2018. Published by Elsevier Inc.
Wang, LiQiang; Li, CuiFeng
2014-10-01
A genetic algorithm (GA) coupled with multiple linear regression (MLR) was used to extract useful features from amino acids and g-gap dipeptides for distinguishing between thermophilic and non-thermophilic proteins. The method was trained by a benchmark dataset of 915 thermophilic and 793 non-thermophilic proteins. The method reached an overall accuracy of 95.4 % in a Jackknife test using nine amino acids, 38 0-gap dipeptides and 29 1-gap dipeptides. The accuracy as a function of protein size ranged between 85.8 and 96.9 %. The overall accuracies of three independent tests were 93, 93.4 and 91.8 %. The observed results of detecting thermophilic proteins suggest that the GA-MLR approach described herein should be a powerful method for selecting features that describe thermostabile machines and be an aid in the design of more stable proteins.
Van Berkel, Gary J.
2015-10-06
A system and method for analyzing a chemical composition of a specimen are described. The system can include at least one pin; a sampling device configured to contact a liquid with a specimen on the at least one pin to form a testing solution; and a stepper mechanism configured to move the at least one pin and the sampling device relative to one another. The system can also include an analytical instrument for determining a chemical composition of the specimen from the testing solution. In particular, the systems and methods described herein enable chemical analysis of specimens, such as tissue, to be evaluated in a manner that the spatial-resolution is limited by the size of the pins used to obtain tissue samples, not the size of the sampling device used to solubilize the samples coupled to the pins.
Recommended Practice for Use of Emissive Probes in Electric Propulsion Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheehan, J. P.; Raitses, Yevgeny; Hershkowitz, Noah
Here, this article provides recommended methods for building, operating, and taking plasma potential measurements from electron-emitting probes in electric propulsion devices, including Hall thrusters, gridded ion engines, and others. The two major techniques, the floating point technique and the inflection point technique, are described in detail as well as calibration and error-reduction methods. The major heating methods are described as well as the various considerations for emissive probe construction. Lastly, special considerations for electric propulsion plasmas are addressed, including high-energy densities, ion flows, magnetic fields, and potential fluctuations. Recommendations for probe design and operation are provided.
Recommended Practice for Use of Emissive Probes in Electric Propulsion Testing
Sheehan, J. P.; Raitses, Yevgeny; Hershkowitz, Noah; ...
2016-11-03
Here, this article provides recommended methods for building, operating, and taking plasma potential measurements from electron-emitting probes in electric propulsion devices, including Hall thrusters, gridded ion engines, and others. The two major techniques, the floating point technique and the inflection point technique, are described in detail as well as calibration and error-reduction methods. The major heating methods are described as well as the various considerations for emissive probe construction. Lastly, special considerations for electric propulsion plasmas are addressed, including high-energy densities, ion flows, magnetic fields, and potential fluctuations. Recommendations for probe design and operation are provided.
Extensions to the Speech Disorders Classification System (SDCS)
Shriberg, Lawrence D.; Fourakis, Marios; Hall, Sheryl D.; Karlsson, Heather B.; Lohmeier, Heather L.; McSweeny, Jane L.; Potter, Nancy L.; Scheer-Cohen, Alison R.; Strand, Edythe A.; Tilkens, Christie M.; Wilson, David L.
2010-01-01
This report describes three extensions to a classification system for pediatric speech sound disorders termed the Speech Disorders Classification System (SDCS). Part I describes a classification extension to the SDCS to differentiate motor speech disorders from speech delay and to differentiate among three subtypes of motor speech disorders. Part II describes the Madison Speech Assessment Protocol (MSAP), an approximately two-hour battery of 25 measures that includes 15 speech tests and tasks. Part III describes the Competence, Precision, and Stability Analytics (CPSA) framework, a current set of approximately 90 perceptual- and acoustic-based indices of speech, prosody, and voice used to quantify and classify subtypes of Speech Sound Disorders (SSD). A companion paper, Shriberg, Fourakis, et al. (2010) provides reliability estimates for the perceptual and acoustic data reduction methods used in the SDCS. The agreement estimates in the companion paper support the reliability of SDCS methods and illustrate the complementary roles of perceptual and acoustic methods in diagnostic analyses of SSD of unknown origin. Examples of research using the extensions to the SDCS described in the present report include diagnostic findings for a sample of youth with motor speech disorders associated with galactosemia (Shriberg, Potter, & Strand, 2010) and a test of the hypothesis of apraxia of speech in a group of children with autism spectrum disorders (Shriberg, Paul, Black, & van Santen, 2010). All SDCS methods and reference databases running in the PEPPER (Programs to Examine Phonetic and Phonologic Evaluation Records; [Shriberg, Allen, McSweeny, & Wilson, 2001]) environment will be disseminated without cost when complete. PMID:20831378
Frequency-Domain Identification Of Aeroelastic Modes
NASA Technical Reports Server (NTRS)
Acree, C. W., Jr.; Tischler, Mark B.
1991-01-01
Report describes flight measurements and frequency-domain analyses of aeroelastic vibrational modes of wings of XV-15 tilt-rotor aircraft. Begins with description of flight-test methods. Followed by brief discussion of methods of analysis, which include Fourier-transform computations using chirp z transformers, use of coherence and other spectral functions, and methods and computer programs to obtain frequencies and damping coefficients from measurements. Includes brief description of results of flight tests and comparisions among various experimental and theoretical results. Ends with section on conclusions and recommended improvements in techniques.
Standard method of test for grindability of coal by the Hardgrove-machine method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-01-01
A procedure is described for sampling coal, grinding in a Hardgrove grinding machine, and passing through standard sieves to determine the degree of pulverization of coals. The grindability index of the coal tested is calculated from a calibration chart prepared by plotting weight of material passing a No. 200 sieve versus the Hardgrove Grindability Index for the standard reference samples. The Hardgrove machine is shown schematically. The method for preparing and determining grindability indexes of standard reference samples is given in the appendix. (BLM)
Automatic Fringe Detection for Oil Film Interferometry Measurement of Skin Friction
NASA Technical Reports Server (NTRS)
Naughton, Jonathan W.; Decker, Robert K.; Jafari, Farhad
2001-01-01
This report summarizes two years of work on investigating algorithms for automatically detecting fringe patterns in images acquired using oil-drop interferometry for the determination of skin friction. Several different analysis methods were tested, and a combination of a windowed Fourier transform followed by a correlation was found to be most effective. The implementation of this method is discussed and details of the process are described. The results indicate that this method shows promise for automating the fringe detection process, but further testing is required.
Method and apparatus for determining tensile strength
Ratigan, J.L.
1982-05-28
A method and apparatus is described for determining the statistical distribution of apparent tensile strength of rock, the size effect with respect to tensile strength, as well as apparent deformation modulus of both intact and fractured or jointed rock. The method is carried out by inserting a plug of deformable material, such as rubber, in an opening of a specimen to be tested. The deformable material is loaded by an upper and lower platen until the specimen ruptures, whereafter the tensile strength is calculated based on the parameters of the test specimen and apparatus.
Illinois method for the design of dense-graded emulsion base mixes : final report.
DOT National Transportation Integrated Search
1981-01-01
This study evaluated the practicality of using a basic test method developed at the University of Illinois. The report describes the use of the Illinois equation for predicting trial asphalt content, compares the results obtained with two CSS emulsio...
Development of EPA OTM 10 for Landfill Applications
In 2006, the U.S. Environmental Protection Agency posted a new test method on its website called OTM 10 which describes direct measurement of pollutant mass emission flux from area sources using ground-based optical remote sensing. The method has validated application to relative...
Gordeev, Konstantin; Shinkarev, Sergey; Ilyin, Leonid; Bouville, André; Hoshi, Masaharu; Luckyanov, Nickolas; Simon, Steven L
2006-02-01
A short analysis of all 111 atmospheric events conducted at the Semipalatinsk Test Site (STS) in 1949-1962 with regard to significant off-site exposure (more than 5 mSv of the effective dose during the first year after the explosion) has been made. The analytical method used to assess external exposure to the residents living in settlements near the STS is described. This method makes use of the archival data on the radiological conditions, including the measurements of exposure rate. Special attention was given to the residents of Dolon and Kanonerka villages exposed mainly as a result of the first test, detonated on August 29, 1949. For the residents of those settlements born in 1935, the dose estimates calculated according to the analytical method, are compared to those derived from the thermoluminescence measurements in bricks and electron paramagnetic resonance measurements in teeth. The methods described in this paper were used for external dose assessment for the cohort members at an initial stage of an ongoing epidemiological study conducted by the U.S. National Cancer Institute in the Republic of Kazakhstan. Recently revised methods and estimates of external exposure for that cohort are given in another paper (Simon et al.) in this conference.
Debridement: controlling the necrotic/cellular burden.
Ayello, Elizabeth A; Cuddigan, Janet E
2004-03-01
To provide physicians and nurses with an overview of the options for debriding a chronic wound to improve wound healing. This continuing education activity is intended for physicians and nurses with an interest in learning about methods for debriding chronic wounds to promote wound healing. After reading the article and taking the test, the participant will be able to: 1. Describe the 4 types of debridement most commonly used in clinical practice. 2. Describe when to debride a wound and how to determine which method to use.
Using a Model to Describe Students' Inductive Reasoning in Problem Solving
ERIC Educational Resources Information Center
Canadas, Maria C.; Castro, Encarnacion; Castro, Enrique
2009-01-01
Introduction: We present some aspects of a wider investigation (Canadas, 2007), whose main objective is to describe and characterize inductive reasoning used by Spanish students in years 9 and 10 when they work on problems that involved linear and quadratic sequences. Method: We produced a test composed of six problems with different…
Lightweight long life heat exchanger
NASA Technical Reports Server (NTRS)
Moore, E. K.
1975-01-01
The design, fabrication, and evaluation of a full scale shuttle-type condensing heat exchanger constructed of aluminum and utilizing aluminum clad titanium parting sheets is described. A long term salt spray test of candidate parting sheet specimens is described. The results of an investigation into an alternate method of making composite sheet material are discussed.
TEACHING MACHINES AND PROGRAMMED LEARNING, A SOURCE BOOK.
ERIC Educational Resources Information Center
LUMSDAINE, A.A., ED.; GLASER, ROBERT, ED.
BROUGHT TOGETHER HERE IS THE WIDELY-SCATTERED LITERATURE ON SELF-INSTRUCTIONAL PROGRAMS AND DEVICES BY LEADERS, PAST AND PRESENT, IN THEIR DEVELOPMENT. S.L. PRESSEY IN HIS ARTICLES DESCRIBES THE APPARATUS, METHODS, THEORY, AND RESULTS ATTENDANT UPON USE OF HIS TEST-SCORING DEVICES. B.F. SKINNER IN HIS ARTICLES DEVELOPS THEORY, DESCRIBES MACHINES,…
NASA Astrophysics Data System (ADS)
Derajat; Hariowibowo, Hindawan
2018-04-01
The new proposed In-Flight Pitot Static Calibration Method has been carried out during Development and Qualification of CN235-100 MPA (Military Patrol Aircraft). This method is expected to reduce flight hours, less human resources required, no additional special equipment, simple analysis calculation and finally by using this method it is expected to automatically minimized operational cost. At The Indonesian Aerospace (IAe) Flight Test Center Division, the development and updating of new flight test technique and data analysis method as specially for flight physics test subject are still continued to be developed as long as it safety for flight and give additional value for the industrial side. More than 30 years, Flight Test Data Engineers at The Flight Test center Division work together with the Air Crew (Test Pilots, Co-Pilots, and Flight Test Engineers) to execute the flight test activity with standard procedure for both the existance or development test techniques and test data analysis. In this paper the approximation of mathematical model, data reduction and flight test technique of The In-Flight Pitot Static Calibration by using Radio Altimeter as reference will be described and the test results had been compared with another methods ie. By using Global Position System (GPS) and the traditional method (Tower Fly By Method) which were used previously during this Flight Test Program (Ref. [10]). The flight test data case are using CN235-100 MPA flight test data during development and Qualification Flight Test Program at Cazaux Airport, France, in June-November 2009 (Ref. [2]).
Clinical perspective of cell-free DNA testing for fetal aneuploidies.
Gratacós, Eduard; Nicolaides, Kypros
2014-01-01
Cell-free DNA testing in maternal blood provides the most effective method of screening for trisomy 21, with a reported detection rate of 99% and a false positive rate of less than 0.1%. After many years of research, this method is now commercially available and is carried out in an increasing number of patients, and there is an expanding number of conditions that can be screened for. However, the application of these methods in clinical practice requires a careful analysis. Current first-trimester screening strategies are based on a complex combination of tests, aiming at detecting fetal defects and predicting the risk of main pregnancy complications. It is therefore necessary to define the optimal way of combining cell-free DNA testing with current first-trimester screening methods. In this concise review we describe the basis of cell-free DNA testing and discuss the potential approaches for its implementation in combination with current tests in the first trimester. © 2014 S. Karger AG, Basel.
Analysis of Parasite and Other Skewed Counts
Alexander, Neal
2012-01-01
Objective To review methods for the statistical analysis of parasite and other skewed count data. Methods Statistical methods for skewed count data are described and compared, with reference to those used over a ten year period of Tropical Medicine and International Health. Two parasitological datasets are used for illustration. Results Ninety papers were identified, 89 with descriptive and 60 with inferential analysis. A lack of clarity is noted in identifying measures of location, in particular the Williams and geometric mean. The different measures are compared, emphasizing the legitimacy of the arithmetic mean for skewed data. In the published papers, the t test and related methods were often used on untransformed data, which is likely to be invalid. Several approaches to inferential analysis are described, emphasizing 1) non-parametric methods, while noting that they are not simply comparisons of medians, and 2) generalized linear modelling, in particular with the negative binomial distribution. Additional methods, such as the bootstrap, with potential for greater use are described. Conclusions Clarity is recommended when describing transformations and measures of location. It is suggested that non-parametric methods and generalized linear models are likely to be sufficient for most analyses. PMID:22943299
ERIC Educational Resources Information Center
Spaulding, Bruce
This first in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II introduces the student/trainee to the basic behavior of ultrasound, describes ultrasonic test equipment, and outlines the principal methods of ultrasonic testing. The module follows a typical format that includes the following sections: (1)…
ERIC Educational Resources Information Center
Reardon, Sean F.; Kalogrides, Demetra; Ho, Andrew D.
2017-01-01
There is no comprehensive database of U.S. district-level test scores that is comparable across states. We describe and evaluate a method for constructing such a database. First, we estimate linear, reliability-adjusted linking transformations from state test score scales to the scale of the National Assessment of Educational Progress (NAEP). We…
USDA-ARS?s Scientific Manuscript database
In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues from the Fast Antimicrobial Screen Test to the Kidney Inhibition Swab (KIS(TM)). Here, we describe the use of KIS(TM) test for the detection of penicillin G res...
Small, high-pressure liquid hydrogen turbopump
NASA Technical Reports Server (NTRS)
Csomor, A.; Sutton, R.
1977-01-01
A high pressure, liquid hydrogen turbopump was designed, fabricated, and tested to a maximum speed of 9739 rad/s and a maximum pump discharge pressure of 2861 N/sq. cm. The approaches used in the analysis and design of the turbopump are described, and fabrication methods are discussed. Data obtained from gas generator tests, turbine performance calibration, and turbopump testing are presented.
Cheating in Middle School and High School
ERIC Educational Resources Information Center
Strom, Paris S.; Strom, Robert D.
2007-01-01
There is increasing concern about cheating in the secondary schools. This article describes the prevalence of dishonesty in testing, motivation for student cheating, new forms of deception using technology tools, initiatives to protect security of tests, methods students use to obtain papers without crediting the original source, tools for…
Problem-Solving Test: Restriction Endonuclease Mapping
ERIC Educational Resources Information Center
Szeberenyi, Jozsef
2011-01-01
The term "restriction endonuclease mapping" covers a number of related techniques used to identify specific restriction enzyme recognition sites on small DNA molecules. A method for restriction endonuclease mapping of a 1,000-basepair (bp)-long DNA molecule is described in the fictitious experiment of this test. The most important fact needed to…
Regeneration of Exhausted Arsenic Adsorptive media of a Full Scale Treatment System
This presentation will describe the method and results of laboratory tests showing the feasibility of regenerating exhausted, iron-based, adsorptive media and the results of a follow up regeneration test at a full scale system in Twentynine Palms CA. The laboratory studies on se...
Testing the Untestable: A Vision Screening Program for Exceptional Children.
ERIC Educational Resources Information Center
Bishop, Virginia E.; Godolphin, Vivienne
Based on a longitudinal study of vision screening techniques for handicapped children at the Chester County (Pennsylvania) Child Development Center, the paper reports on the development of a battery of effective vision screening methods for children with low functioning handicapped children. Specific tests are described, including the Sheridan…
Sensitivities of Soap Solutions in Leak Detection
NASA Technical Reports Server (NTRS)
Stuck, D.; Lam, D. Q.; Daniels, C.
1985-01-01
Document describes method for determining minimum leak rate to which soap-solution leak detectors sensitive. Bubbles formed at smaller leak rates than previously assumed. In addition to presenting test results, document discusses effects of joint-flange configurations, properties of soap solutions, and correlation of test results with earlier data.
USDA-ARS?s Scientific Manuscript database
A variety of methods have been used by different research groups to “challenge” inoculate American elms (Ulmus americana) with the purpose of determining whether some clones may be resistant to the Dutch elm disease fungus. The methods used by seven research groups are described, along with observat...
ERIC Educational Resources Information Center
Hayes, Andrew F.; Preacher, Kristopher J.
2010-01-01
Most treatments of indirect effects and mediation in the statistical methods literature and the corresponding methods used by behavioral scientists have assumed linear relationships between variables in the causal system. Here we describe and extend a method first introduced by Stolzenberg (1980) for estimating indirect effects in models of…
PV systems photoelectric parameters determining for field conditions and real operation conditions
NASA Astrophysics Data System (ADS)
Shepovalova, Olga V.
2018-05-01
In this work, research experience and reference documentation have been generalized related to PV systems photoelectric parameters (PV array output parameters) determining. The basic method has been presented that makes it possible to determine photoelectric parameters with the state-of-the-art reliability and repeatability. This method provides an effective tool for PV systems comparison and evaluation of PV system parameters that the end-user will have in the course of its real operation for compliance with those stipulated in reference documentation. The method takes in consideration all parameters that may possibly affect photoelectric performance and that are supported by sufficiently valid procedures for their values testing. Test conditions, requirements for equipment subject to tests and test preparations have been established and the test procedure for fully equipped PV system in field tests and in real operation conditions has been described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jy-An John; Jiang, Hao
2016-01-12
To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at the Oak Ridge National Laboratory (ORNL) and is described fully in US Patent Application 20060070455, “Expanded plug method for developing circumferential mechanical properties of tubular materials.” This method is designed for testing fuel rod cladding ductility in a hot cell using an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are themore » simplicity of measuring the test component assembly in the hot cell and the direct measurement of the specimen’s strain. It was also found that cladding strength could be determined from the test results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabourin, P.F.
1995-04-25
An apparatus and method for ultrasonic reconstruction and testing of a non-visible turbine rotor blade attachment structure is described. The method of the invention includes positioning transducers at a first location to obtain slot region scan data corresponding to a slot region of the non-visible turbine rotor blade attachment structure, and positioning transducers at a second location to obtain straddle-mount region scan data corresponding to a straddle-mount region of the non-visible turbine rotor blade attachment structure. The shape of the non-visible turbine rotor blade attachment structure is reconstructed from the slot region scan data and the straddle-mount region scan datamore » to form reconstruction data. The reconstruction data is used to select test scan positions for ultrasonic testing. Ultrasonic testing is then performed at the selected test scan positions. 11 figs.« less
Statistical assessment of speech system performance
NASA Technical Reports Server (NTRS)
Moshier, Stephen L.
1977-01-01
Methods for the normalization of performance tests results of speech recognition systems are presented. Technological accomplishments in speech recognition systems, as well as planned research activities are described.
[Automated analyzer of enzyme immunoassay].
Osawa, S
1995-09-01
Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.
Development of wheelchair caster testing equipment and preliminary testing of caster models
Mhatre, Anand; Ott, Joseph
2017-01-01
Background Because of the adverse environmental conditions present in less-resourced environments (LREs), the World Health Organization (WHO) has recommended that specialised wheelchair test methods may need to be developed to support product quality standards in these environments. A group of experts identified caster test methods as a high priority because of their common failure in LREs, and the insufficiency of existing test methods described in the International Organization for Standardization (ISO) Wheelchair Testing Standards (ISO 7176). Objectives To develop and demonstrate the feasibility of a caster system test method. Method Background literature and expert opinions were collected to identify existing caster test methods, caster failures common in LREs and environmental conditions present in LREs. Several conceptual designs for the caster testing method were developed, and through an iterative process using expert feedback, a final concept and a design were developed and a prototype was fabricated. Feasibility tests were conducted by testing a series of caster systems from wheelchairs used in LREs, and failure modes were recorded and compared to anecdotal reports about field failures. Results The new caster testing system was developed and it provides the flexibility to expose caster systems to typical conditions in LREs. Caster failures such as stem bolt fractures, fork fractures, bearing failures and tire cracking occurred during testing trials and are consistent with field failures. Conclusion The new caster test system has the capability to incorporate necessary test factors that degrade caster quality in LREs. Future work includes developing and validating a testing protocol that results in failure modes common during wheelchair use in LRE. PMID:29062762
A Test of Genetic Algorithms in Relevance Feedback.
ERIC Educational Resources Information Center
Lopez-Pujalte, Cristina; Guerrero Bote, Vicente P.; Moya Anegon, Felix de
2002-01-01
Discussion of information retrieval, query optimization techniques, and relevance feedback focuses on genetic algorithms, which are derived from artificial intelligence techniques. Describes an evaluation of different genetic algorithms using a residual collection method and compares results with the Ide dec-hi method (Salton and Buckley, 1990…
Binary sensitivity and specificity metrics are not adequate to describe the performance of quantitative microbial source tracking methods because the estimates depend on the amount of material tested and limit of detection. We introduce a new framework to compare the performance ...
NEW METHOD FOR DETERMINING EFFLUENT TOXICITY USING DUCKWEED (LEMNA MINOR)
Duckweed (Lemna minor), a small vascular plant, grows rapidly, is sensitive to a wide variety of toxicants and is easy to culture. ethod is described that measures duckweed frond growth and chlorophyll levels as indicators of growth inhibition. he method requires a small testing ...
Investigating Learning with an Interactive Tutorial: A Mixed-Methods Strategy
ERIC Educational Resources Information Center
de Villiers, M. R.; Becker, Daphne
2017-01-01
From the perspective of parallel mixed-methods research, this paper describes interactivity research that employed usability-testing technology to analyse cognitive learning processes; personal learning styles and times; and errors-and-recovery of learners using an interactive e-learning tutorial called "Relations." "Relations"…
Engineering Aerothermal Analysis for X-34 Thermal Protection System Design
NASA Technical Reports Server (NTRS)
Wurster, Kathryn E.; Riley, Christopher J.; Zoby, E. Vincent
1998-01-01
Design of the thermal protection system for any hypersonic flight vehicle requires determination of both the peak temperatures over the surface and the heating-rate history along the flight profile. In this paper, the process used to generate the aerothermal environments required for the X-34 Testbed Technology Demonstrator thermal protection system design is described as it has evolved from a relatively simplistic approach based on engineering methods applied to critical areas to one of detailed analyses over the entire vehicle. A brief description of the trajectory development leading to the selection of the thermal protection system design trajectory is included. Comparisons of engineering heating predictions with wind-tunnel test data and with results obtained using a Navier-Stokes flowfield code and an inviscid/boundary layer method are shown. Good agreement is demonstrated among all these methods for both the ground-test condition and the peak heating flight condition. Finally, the detailed analysis using engineering methods to interpolate the surface-heating-rate results from the inviscid/boundary layer method to predict the required thermal environments is described and results presented.
Engineering Aerothermal Analysis for X-34 Thermal Protection System Design
NASA Technical Reports Server (NTRS)
Wurster, Kathryn E.; Riley, Christopher J.; Zoby, E. Vincent
1998-01-01
Design of the thermal protection system for any hypersonic flight vehicle requires determination of both the peak temperatures over the surface and the heating-rate history along the flight profile. In this paper, the process used to generate the aerothermal environments required for the X-34 Testbed Technology Demonstrator thermal protection system design is described as it has evolved from a relatively simplistic approach based on engineering methods applied to critical areas to one of detailed analyses over the entire vehicle. A brief description of the trajectory development leading to the selection of the thermal protection system design trajectory is included. Comparisons of engineering heating predictions with wind-tunnel test data and with results obtained using a Navier- Stokes flowfield code and an inviscid/boundary layer method are shown. Good agreement is demonstrated among all these methods for both the ground-test condition and the peak heating flight condition. Finally, the detailed analysis using engineering methods to interpolate the surface-heating-rate results from the inviscid/boundary layer method to predict the required thermal environments is described and results presented.
NASA Astrophysics Data System (ADS)
Astashev, M. E.; Belosludtsev, K. N.; Kharakoz, D. P.
2014-05-01
One of the most accurate methods for measuring the compressibility of liquids is resonance measurement of sound velocity in a fixed-length interferometer. This method combines high sensitivity, accuracy, and small sample volume of the test liquid. The measuring principle is to study the resonance properties of a composite resonator that contains a test liquid sample. Ealier, the phase-locked loop (PLL) scheme was used for this. In this paper, we propose an alternative measurement scheme based on digital analysis of harmonic signals, describe the implementation of this scheme using commercially available data acquisition modules, and give examples of test measurements with accuracy evaluations of the results.
Enabling multiplexed testing of pooled donor cells through whole-genome sequencing.
Chan, Yingleong; Chan, Ying Kai; Goodman, Daniel B; Guo, Xiaoge; Chavez, Alejandro; Lim, Elaine T; Church, George M
2018-04-19
We describe a method that enables the multiplex screening of a pool of many different donor cell lines. Our method accurately predicts each donor proportion from the pool without requiring the use of unique DNA barcodes as markers of donor identity. Instead, we take advantage of common single nucleotide polymorphisms, whole-genome sequencing, and an algorithm to calculate the proportions from the sequencing data. By testing using simulated and real data, we showed that our method robustly predicts the individual proportions from a mixed-pool of numerous donors, thus enabling the multiplexed testing of diverse donor cells en masse.More information is available at https://pgpresearch.med.harvard.edu/poolseq/.
A preliminary test method for masonry heater particulate matter and carbon monoxide emissions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stern, C.H.; Jaasma, D.R.; Shelton, J.W.
1991-08-01
A test method for determining carbon monoxide (CO) and particulate matter (PM) emissions from masonry heaters is described and results of tests on two masonry heaters are presented. The method specifies fueling protocol and laboratory measurement procedures for determination of both emission factors (g/kg) and rates (g/hr). The fuel load size and fueling intervals are dependent upon the firebox volume of the masonry heater. The test method starts with a room temperature masonry heater and involves five firings to achieve burn rates in two ranges, where the burn rate is defined as the dry mass of the fuel load dividedmore » by the time between loadings. Emission samples are extracted from a dilution tunnel with a set flow rate and configuration. Particulate matter sampling is similar to US EPA Method 5G for woodstoves, and Co concentration is measured by a nondispersive infrared (NDIR) gas analyzer. The emissions results for each firing are weighted according to EPA Method 28 to obtain the overall emission totals for the test.« less
Development of optimized, graded-permeability axial groove heat pipes
NASA Technical Reports Server (NTRS)
Kapolnek, Michael R.; Holmes, H. Rolland
1988-01-01
Heat pipe performance can usually be improved by uniformly varying or grading wick permeability from end to end. A unique and cost effective method for grading the permeability of an axial groove heat pipe is described - selective chemical etching of the pipe casing. This method was developed and demonstrated on a proof-of-concept test article. The process improved the test article's performance by 50 percent. Further improvement is possible through the use of optimally etched grooves.
Tomasino, Stephen F; Fiumara, Rebecca M; Cottrill, Michele P
2006-01-01
The AOAC Use-Dilution methods do not provide procedures to enumerate the test microbe on stainless steel carriers (penicylinders) or guidance on the expected target populations of the test microbe (i.e., a performance standard). This report describes the procedures used by the U.S. Environmental Protection Agency to enumerate the test microbe (carrier counts) associated with conducting the Use-Dilution method with Staphylococcus aureus (Method 955.15) and Pseudomonas aeruginosa (Method 964.02) and the examination of historical data. The carrier count procedure involves the random selection of carriers, shearing bacterial cells from the carrier surface through sonication, and plating of serially diluted inoculum on trypticase soy agar. For each Use-Dilution test conducted, the official AOAC method was strictly followed for carrier preparation, culture initiation, test culture preparation, and carrier inoculation steps. Carrier count data from 78 Use-Dilution tests conducted over a 6-year period were compiled and analyzed. A mean carrier count of 6.6 logs (approximately 4.0 x 10(6) colony-forming units/carrier) was calculated for both S. aureus and P. aeruginosa. Of the mean values, 95% fell within +/- 2 repeatability standard deviations. The enumeration procedure and target carrier counts are desirable for standardizing the Use-Dilution methods, increasing their reproducibility, and ensuring the quality of the data.
A Novel Quantum Dots-Based Point of Care Test for Syphilis
NASA Astrophysics Data System (ADS)
Yang, Hao; Li, Ding; He, Rong; Guo, Qin; Wang, Kan; Zhang, Xueqing; Huang, Peng; Cui, Daxiang
2010-05-01
One-step lateral flow test is recommended as the first line screening of syphilis for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent POC (Point Of Care) test method to be used for screening for syphilis. The method was designed to combine the rapidness of lateral flow test and sensitiveness of fluorescent method. 50 syphilis-positive specimens and 50 healthy specimens conformed by Treponema pallidum particle agglutination (TPPA) were tested with Quantum Dot-labeled and colloidal gold-labeled lateral flow test strips, respectively. The results showed that both sensitivity and specificity of the quantum dots-based method reached up to 100% (95% confidence interval [CI], 91-100%), while those of the colloidal gold-based method were 82% (95% CI, 68-91%) and 100% (95% CI, 91-100%), respectively. In addition, the naked-eye detection limit of quantum dot-based method could achieve 2 ng/ml of anti-TP47 polyclonal antibodies purified by affinity chromatography with TP47 antigen, which was tenfold higher than that of colloidal gold-based method. In conclusion, the quantum dots were found to be suitable for labels of lateral flow test strip. Its ease of use, sensitiveness and low cost make it well-suited for population-based on-the-site syphilis screening.
Durability of ITO-MgF2 Films for Space-Inflatable Polymer Structures
NASA Technical Reports Server (NTRS)
Kerslake, Thomas W.; Waters, Deborah L.; Schieman, David A.; Hambourger, Paul D.
2003-01-01
This paper presents results from ITO-MgF2 film durability evaluations that included tape peel, fold, thermal cycle, and AO exposure testing. Polymer coupon preparation is described as well as ITO-MgF2 film deposition equipment, procedures and film characterization. Durability testing methods are also described. The pre- and post-test condition of the films is assessed visually, microscopically, and electrically. Results show that at 500 ITO - 9 vol% MgF2 film is suitable to protect polymer surfaces, such as those used in space-inflatable structures of the PowerSphere microsatellite concept, during a 1-year Earth orbiting mission. Future plans for ground-based and orbital testing of this film are also discussed.
The "four quadrants" approach to clinical ethics case analysis; an application and review.
Sokol, D K
2008-07-01
In 1982, Jonsen, Siegler and Winslade published Clinical Ethics, in which they described the "four quadrants" approach, a new method of analysing clinical ethics cases. Although the book is now in its 6th edition, a literature search has revealed only one academic paper demonstrating the method at work. This paper is an attempt to start filling this gap. As a way of describing and testing the approach, I apply the four quadrants method to a detailed clinical ethics case. The analysis is interspersed with reflections on the method itself. It is hoped that this experiment will encourage ethicists and clinicians to devote more attention to this neglected approach.
Measuring and Specifying Combinatorial Coverage of Test Input Configurations
Kuhn, D. Richard; Kacker, Raghu N.; Lei, Yu
2015-01-01
A key issue in testing is how many tests are needed for a required level of coverage or fault detection. Estimates are often based on error rates in initial testing, or on code coverage. For example, tests may be run until a desired level of statement or branch coverage is achieved. Combinatorial methods present an opportunity for a different approach to estimating required test set size, using characteristics of the test set. This paper describes methods for estimating the coverage of, and ability to detect, t-way interaction faults of a test set based on a covering array. We also develop a connection between (static) combinatorial coverage and (dynamic) code coverage, such that if a specific condition is satisfied, 100% branch coverage is assured. Using these results, we propose practical recommendations for using combinatorial coverage in specifying test requirements. PMID:28133442
Mechanical properties of sugar beet root during storage
NASA Astrophysics Data System (ADS)
Nedomová, Šárka; Kumbár, Vojtěch; Pytel, Roman; Buchar, Jaroslav
2017-10-01
This paper is an investigation via two experimental methods, of the textural properties of sugar beet roots during the storage period. In the work, sugar beet roots mechanical properties were evaluated during the post-harvest period - 1, 8, 22, 43, and 71 days after crop. Both experimental methods, i.e. compression test and puncture test, suggest that the failure strength of the sugar beet root increases with the storage time. The parameters obtained using the puncture test, are more sensitive to the storage duration than those obtained by way of the compression test. We also found that such mechanical properties served as a reliable tool for monitoring the progress of sugar beet roots storage. The described methods could also be used to highlight important information on sugar beet evolution during storage.
NASA Astrophysics Data System (ADS)
Obuchowski, Nancy A.; Bullen, Jennifer A.
2018-04-01
Receiver operating characteristic (ROC) analysis is a tool used to describe the discrimination accuracy of a diagnostic test or prediction model. While sensitivity and specificity are the basic metrics of accuracy, they have many limitations when characterizing test accuracy, particularly when comparing the accuracies of competing tests. In this article we review the basic study design features of ROC studies, illustrate sample size calculations, present statistical methods for measuring and comparing accuracy, and highlight commonly used ROC software. We include descriptions of multi-reader ROC study design and analysis, address frequently seen problems of verification and location bias, discuss clustered data, and provide strategies for testing endpoints in ROC studies. The methods are illustrated with a study of transmission ultrasound for diagnosing breast lesions.
An assessment of unstructured grid technology for timely CFD analysis
NASA Technical Reports Server (NTRS)
Kinard, Tom A.; Schabowski, Deanne M.
1995-01-01
An assessment of two unstructured methods is presented in this paper. A tetrahedral unstructured method USM3D, developed at NASA Langley Research Center is compared to a Cartesian unstructured method, SPLITFLOW, developed at Lockheed Fort Worth Company. USM3D is an upwind finite volume solver that accepts grids generated primarily from the Vgrid grid generator. SPLITFLOW combines an unstructured grid generator with an implicit flow solver in one package. Both methods are exercised on three test cases, a wing, and a wing body, and a fully expanded nozzle. The results for the first two runs are included here and compared to the structured grid method TEAM and to available test data. On each test case, the set up procedure are described, including any difficulties that were encountered. Detailed descriptions of the solvers are not included in this paper.
Yield Model Development (YMD) implementation plan for fiscal years 1981 and 1982
NASA Technical Reports Server (NTRS)
Ambroziak, R. A. (Principal Investigator)
1981-01-01
A plan is described for supporting USDA crop production forecasting and estimation by (1) testing, evaluating, and selecting crop yield models for application testing; (2) identifying areas of feasible research for improvement of models; and (3) conducting research to modify existing models and to develop new crop yield assessment methods. Tasks to be performed for each of these efforts are described as well as for project management and support. The responsibilities of USDA, USDC, USDI, and NASA are delineated as well as problem areas to be addressed.
Scatter of X-rays on polished surfaces
NASA Technical Reports Server (NTRS)
Hasinger, G.
1981-01-01
In investigating the dispersion properties of telescope mirrors used in X-ray astronomy, the slight scattering characteristics of X-ray radiation by statistically rough surfaces were examined. The mathematics and geometry of scattering theory are described. The measurement test assembly is described and results of measurements on samples of plane mirrors are given. Measurement results are evaluated. The direct beam, the convolution of the direct beam and the scattering halo, curve fitting by the method of least squares, various autocorrelation functions, results of the fitting procedure for small scattering, and deviations in the kernel of the scattering distribution are presented. A procedure for quality testing of mirror systems through diagnosis of rough surfaces is described.
Photodetector timing research at Fermilab
Ramberg, E.; Ronzhin, A.; Albrow, M.; ...
2011-01-01
We describe here the outlines of research undertaken by Fermilab into timing characteristics of photodetectors. We describe our experimental method and give benchtop results on the timing resolution of micro-channel plate photomultipliers (MCP-PMT) and silicon photomultipliers (SiPM). In addition, we describe results of various configurations of these detectors, along with quartz radiators, in particle test beams at Fermilab. Results for timing of scintillator light using the DRS4 high speed digitizer are also presented.
NASA Astrophysics Data System (ADS)
Dörr, Dominik; Joppich, Tobias; Schirmaier, Fabian; Mosthaf, Tobias; Kärger, Luise; Henning, Frank
2016-10-01
Thermoforming of continuously fiber reinforced thermoplastics (CFRTP) is ideally suited to thin walled and complex shaped products. By means of forming simulation, an initial validation of the producibility of a specific geometry, an optimization of the forming process and the prediction of fiber-reorientation due to forming is possible. Nevertheless, applied methods need to be validated. Therefor a method is presented, which enables the calculation of error measures for the mismatch between simulation results and experimental tests, based on measurements with a conventional coordinate measuring device. As a quantitative measure, describing the curvature is provided, the presented method is also suitable for numerical or experimental sensitivity studies on wrinkling behavior. The applied methods for forming simulation, implemented in Abaqus explicit, are presented and applied to a generic geometry. The same geometry is tested experimentally and simulation and test results are compared by the proposed validation method.
NASA Astrophysics Data System (ADS)
Nugroho, A.; Abdurohman, K.; Kusmono; Hestiawan, H.; Jamasri
2018-04-01
This paper described the effect of different type of manufacturing method to tensile properties of hybrid composite woven agel leaf fiber and glass fiber as an alternative of LSU structure material. The research was done by using 3 ply of woven agel leaf fiber (ALF) and 3 ply of glass fiber (wr200) while the matrix was using unsaturated polyester. Composite manufacturing method used hand lay-up and vacuum bagging. Tensile test conducted with Tensilon universal testing machine, specimen shape and size according to standard size ASTM D 638. Based on tensile test result showed that the tensile strength of agel leaf fiber composite with unsaturated polyester matrix is 54.5 MPa by hand lay-up and 84.6 MPa with vacuum bagging method. From result of tensile test, hybrid fiber agel composite and glass fiber with unsaturated polyester matrix have potential as LSU structure.
Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testingmore » by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.« less
Rampling, A; Whitby, J L; Wildy, P
1975-11-01
A method for pyocin-sensitivity typing by means of "phage-free" preparations of pyocin is described. The method was tested on 227 isolates of P. aeruginosa, collected from 34 different foci of infection in hospitals in the British Isles and the results were compared with those for combined serological and phage typing of all strains and pyocin production of 105 of the isolates. It is concluded that pyocin-sensitivity typing is a simple and reliable method giving a high degree of discrimination, comparable to that of combined serological and phage typing, and it is suitable for use in routine hospital laboratories.
Quantitative analysis of tympanic membrane perforation: a simple and reliable method.
Ibekwe, T S; Adeosun, A A; Nwaorgu, O G
2009-01-01
Accurate assessment of the features of tympanic membrane perforation, especially size, site, duration and aetiology, is important, as it enables optimum management. To describe a simple, cheap and effective method of quantitatively analysing tympanic membrane perforations. The system described comprises a video-otoscope (capable of generating still and video images of the tympanic membrane), adapted via a universal serial bus box to a computer screen, with images analysed using the Image J geometrical analysis software package. The reproducibility of results and their correlation with conventional otoscopic methods of estimation were tested statistically with the paired t-test and correlational tests, using the Statistical Package for the Social Sciences version 11 software. The following equation was generated: P/T x 100 per cent = percentage perforation, where P is the area (in pixels2) of the tympanic membrane perforation and T is the total area (in pixels2) for the entire tympanic membrane (including the perforation). Illustrations are shown. Comparison of blinded data on tympanic membrane perforation area obtained independently from assessments by two trained otologists, of comparative years of experience, using the video-otoscopy system described, showed similar findings, with strong correlations devoid of inter-observer error (p = 0.000, r = 1). Comparison with conventional otoscopic assessment also indicated significant correlation, comparing results for two trained otologists, but some inter-observer variation was present (p = 0.000, r = 0.896). Correlation between the two methods for each of the otologists was also highly significant (p = 0.000). A computer-adapted video-otoscope, with images analysed by Image J software, represents a cheap, reliable, technology-driven, clinical method of quantitative analysis of tympanic membrane perforations and injuries.
Experiences Using Lightweight Formal Methods for Requirements Modeling
NASA Technical Reports Server (NTRS)
Easterbrook, Steve; Lutz, Robyn; Covington, Rick; Kelly, John; Ampo, Yoko; Hamilton, David
1997-01-01
This paper describes three case studies in the lightweight application of formal methods to requirements modeling for spacecraft fault protection systems. The case studies differ from previously reported applications of formal methods in that formal methods were applied very early in the requirements engineering process, to validate the evolving requirements. The results were fed back into the projects, to improve the informal specifications. For each case study, we describe what methods were applied, how they were applied, how much effort was involved, and what the findings were. In all three cases, formal methods enhanced the existing verification and validation processes, by testing key properties of the evolving requirements, and helping to identify weaknesses. We conclude that the benefits gained from early modeling of unstable requirements more than outweigh the effort needed to maintain multiple representations.
TRANDESNF: A computer program for transonic airfoil design and analysis in nonuniform flow
NASA Technical Reports Server (NTRS)
Chang, J. F.; Lan, C. Edward
1987-01-01
The use of a transonic airfoil code for analysis, inverse design, and direct optimization of an airfoil immersed in propfan slipstream is described. A summary of the theoretical method, program capabilities, input format, output variables, and program execution are described. Input data of sample test cases and the corresponding output are given.
NASA Astrophysics Data System (ADS)
Cosgrove, R. B.; Schultz, A.; Imamura, N.
2016-12-01
Although electrostatic equilibrium is always assumed in the ionosphere, there is no good theoretical or experimental justification for the assumption. In fact, recent theoretical investigations suggest that the electrostatic assumption may be grossly in error. If true, many commonly used modeling methods are placed in doubt. For example, the accepted method for calculating ionospheric conductance??field line integration??may be invalid. In this talk we briefly outline the theoretical research that places the electrostatic assumption in doubt, and then describe how comparison of ground magnetic field data with incoherent scatter radar (ISR) data can be used to test the electrostatic assumption in the ionosphere. We describe a recent experiment conducted for the purpose, where an array of magnetometers was temporalily installed under the Poker Flat AMISR.
Problems and Methods of Teaching and Assessment of Students on Day Release in Higher Education.
ERIC Educational Resources Information Center
Trotman-Dickenson, Danusia
1980-01-01
Part-time students' characteristics and teaching and testing preferences were correlated with performance on a standardized economics exam. Learning modules are described. Methods of pinpointing student weaknesses and predicting students' final results are discussed as they relate to other subjects. (MSE)
Estimating the Parameters of the Beta-Binomial Distribution.
ERIC Educational Resources Information Center
Wilcox, Rand R.
1979-01-01
For some situations the beta-binomial distribution might be used to describe the marginal distribution of test scores for a particular population of examinees. Several different methods of approximating the maximum likelihood estimate were investigated, and it was found that the Newton-Raphson method should be used when it yields admissable…
Tests Of Polyurethane And Dichromate Coats On Aluminum
NASA Technical Reports Server (NTRS)
Danford, M. D.
1992-01-01
Report describes experiments to determine relative effectiveness of new polyurethane and more-conventional dichromate coat in helping to retard corrosion of anodized 6061-T6 aluminum. Concludes by suggesting greater protection against corrosion achieved by combining polyurethane-sealing method with hard-anodizing method and by increasing thickness of coat.
Biologically-directed fractionation techniques are a fundamental tool for identifying the cause of toxicity in environmental samples, but few are available for studying mixtures of organic chemicals in aquatic sediments. This paper describes a method for extracting organic chemic...
Multiview Drawing Instruction: A Two-Location Experiment
ERIC Educational Resources Information Center
Connolly, Patrick; Holliday-Darr, Kathryn; Blasko, Dawn G.
2006-01-01
Several methods have been developed, presented, and discussed at recent ASEE and EDGD conferences on the topic of computer-based multiview drawing instruction. While small-scale and localized testing of these instruments and methods has been undertaken, no larger-scale or multi-location experiments have been attempted. This paper describes an…
Physical principles of neutron-gamma materials monitoring
NASA Astrophysics Data System (ADS)
Pekarskii, G. Sh.
1986-03-01
The physical principles of secondary radiation methods in nondestructive testing are discussed. Among the techniques considered are: neutron activation analysis (NAA); the induced-radiation method; and quasialbedo recording of secondary gamma-radiation. Emphasis is given to the neutron-gamma method which consists of exposing test material to a neutron flux and recording the secondary gamma-radiation by means of a spectrometer. The limitations of the method in detecting local inhomogeneous defects (filled pores cracks, and inclusions) in metal layers and multicomponents materials are described, and some advantages of the method over NAA are discussed. Formulas are derived for estimating the optimum density of the gamma-ray flux which is received by the detector.
Physical principles of neutron-gamma materials monitoring
NASA Astrophysics Data System (ADS)
Pekarskii, G. Sh.
1985-07-01
The physical principles of secondary radiation methods in nondestructive testing are discussed. Among the techniques considered are: neutron activation analysis (NAA); the induced-radiation method; and quasialbedo recording of secondary gamma-radiation. Emphasis is given to the neutron-gamma method which consists of exposing test material to a neutron flux and recording the secondary gamma-radiation by means of a spectrometer. The limitations of the method in detecting local inhomogeneous defects (filled pores cracks, and inclusions) in metal layers and multicomponents materials are described, and some advantages of the method over NAA are discussed. Formulas are derived for estimating the optimum density of the gamma-ray flux which is received by the detector.
Landing Procedure in Model Ditching Tests of Bf 109
NASA Technical Reports Server (NTRS)
Sottorf, W.
1949-01-01
The purpose of the model tests is to clarify the motions in the alighting on water of a land plane. After discussion of the model laws, the test method and test procedure are described. The deceleration-time-diagrams of the landing of a model of the Bf 109 show a high deceleration peek of greater than 20g which can be lowered to 4 to 6g by radiator cowling and brake skid.
Environmentally Acceptable Lubricants
2011-11-30
CO2 >60% ASTM D-5864 Shake flask test CO2 >60% EPA 560/6-82-003 BODIS test BOD/COD >60% ISO 10708 Hydrocarbon degradability CEC test Infrared...several criteria proposed over the past few years to describe the point at which chemicals are no longer taken up in the body and bioaccumulated (Arnot...conducted by an approved third -party laboratory. The OSPAR protocols for methods for the testing of chemicals used in the offshore oil industry are
Scaling Methods for Simulating Aircraft In-Flight Icing Encounters
NASA Technical Reports Server (NTRS)
Anderson, David N.; Ruff, Gary A.
1997-01-01
This paper discusses scaling methods which permit the use of subscale models in icing wind tunnels to simulate natural flight in icing. Natural icing conditions exist when air temperatures are below freezing but cloud water droplets are super-cooled liquid. Aircraft flying through such clouds are susceptible to the accretion of ice on the leading edges of unprotected components such as wings, tailplane and engine inlets. To establish the aerodynamic penalties of such ice accretion and to determine what parts need to be protected from ice accretion (by heating, for example), extensive flight and wind-tunnel testing is necessary for new aircraft and components. Testing in icing tunnels is less expensive than flight testing, is safer, and permits better control of the test conditions. However, because of limitations on both model size and operating conditions in wind tunnels, it is often necessary to perform tests with either size or test conditions scaled. This paper describes the theoretical background to the development of icing scaling methods, discusses four methods, and presents results of tests to validate them.
Fracture Test Methods for Plastically Responding COPV Liners
NASA Technical Reports Server (NTRS)
Dawicke, David S.; Lewis, Joseph C.
2009-01-01
An experimental procedure for evaluating the validity of using uniaxial tests to provide a conservative bound on the fatigue crack growth rate behavior small cracks in bi-axially loaded Composite Overwrapped Pressure Vessel (COPV) liners is described. The experimental procedure included the use of a laser notch to quickly generate small surface fatigue cracks with the desired size and aspect ratios. An out-of-plane constraint system was designed to allow fully reversed, fully plastic testing of thin sheet uniaxial coupons. Finally, a method was developed to determine to initiate small cracks in the liner of COPVs.
NASA Astrophysics Data System (ADS)
Shimansky, R. V.; Poleshchuk, A. G.; Korolkov, V. P.; Cherkashin, V. V.
2017-05-01
This paper presents a method of improving the accuracy of a circular laser system in fabrication of large-diameter diffractive optical elements by means of a polar coordinate system and the results of their use. An algorithm for correcting positioning errors of a circular laser writing system developed at the Institute of Automation and Electrometry, SB RAS, is proposed and tested. Highprecision synthesized holograms fabricated by this method and the results of using these elements for testing the 6.5 m diameter aspheric mirror of the James Webb space telescope (JWST) are described..
ERIC Educational Resources Information Center
ALTMANN, BERTHOLD
AFTER A BRIEF SUMMARY OF THE TEST PROGRAM (DESCRIBED MORE FULLY IN LI 000 318), THE STATISTICAL RESULTS TABULATED AS OVERALL "ABC (APPROACH BY CONCEPT)-RELEVANCE RATIOS" AND "ABC-RECALL FIGURES" ARE PRESENTED AND REVIEWED. AN ABSTRACT MODEL DEVELOPED IN ACCORDANCE WITH MAX WEBER'S "IDEALTYPUS" ("DIE OBJEKTIVITAET…
ERIC Educational Resources Information Center
Pratt, Daniel J.; Wine, Jennifer S.; Heuer, Ruth E.; Whitmore, Roy W.; Kelly, Janice E.; Doherty, John M.; Simpson, Joe B.; Marti, Norma
This report describes the methods and procedures used for the field test of the Beginning Postsecondary Students Longitudinal Study First Followup 1996-98 (BPS:96/98). Students in this survey were first interviewed during 1995 as part of the National Postsecondary Student Aid Study 1996 field test. The BPS:96/98 full-scale student sample includes…
A brief introduction to the word associate test
Verplanck, William S.
1992-01-01
An examination format assessing the intraverbal repertoire of individuals in psychology is described and results using it reported. The Associate Test is easy to prepare, to take, and to grade. Its reliability measures are satisfactory; its ability to predict later behavior is reported upon. The Associate Test is computer friendly, and its methods can be applied for examination in any field, and at any level. PMID:22477050
ERIC Educational Resources Information Center
Lapidus, Jodi A.; Bertolli, Jeanne; McGowan, Karen; Sullivan, Patrick
2006-01-01
The goal of this study was to describe HIV risk behaviors, perceptions, testing, and prevention exposure among urban American Indians and Alaska Natives (AI/AN). Interviewers administered a questionnaire to participants recruited through anonymous peer-referral sampling. Chi-square tests and multiple logistic regression were used to compare HIV…
NASA Astrophysics Data System (ADS)
Klejment, Piotr; Kosmala, Alicja; Foltyn, Natalia; Dębski, Wojciech
2017-04-01
The earthquake focus is the point where a rock under external stress starts to fracture. Understanding earthquake nucleation and earthquake dynamics requires thus understanding of fracturing of brittle materials. This, however, is a continuing problem and enduring challenge to geoscience. In spite of significant progress we still do not fully understand the failure of rock materials due to extreme stress concentration in natural condition. One of the reason of this situation is that information about natural or induced seismic events is still not sufficient for precise description of physical processes in seismic foci. One of the possibility of improving this situation is using numerical simulations - a powerful tool of contemporary physics. For this reason we used an advanced implementation of the Discrete Element Method (DEM). DEM's main task is to calculate physical properties of materials which are represented as an assembly of a great number of particles interacting with each other. We analyze the possibility of using DEM for describing materials during so called Brazilian Test. Brazilian Test is a testing method to obtain the tensile strength of brittle material. One of the primary reasons for conducting such simulations is to measure macroscopic parameters of the rock sample. We would like to report our efforts of describing the fracturing process during the Brazilian Test from the microscopic point of view and give an insight into physical processes preceding materials failure.
Clinical Endpoints for the Study of Geographic Atrophy Secondary to Age-Related Macular Degeneration
Sadda, SriniVas R.; Chakravarthy, Usha; Birch, David G.; Staurenghi, Giovanni; Henry, Erin C.; Brittain, Christopher
2017-01-01
Purpose To summarize the recent literature describing the application of modern technologies in the study of patients with geographic atrophy (GA) secondary to age-related macular degeneration (AMD). Methods Review of the literature describing the terms and definitions used to describe GA, imaging modalities used to capture and measure GA, and the tests of visual function and functional deficits that occur in patients with GA. Results In this paper we describe the evolution of the definitions used to describe GA. We compare imaging modalities used in the characterization of GA, report on the sensitivity and specificity of the techniques where data exist, and describe the correlations between these various modes of capturing the presence of GA. We review the functional tests that have been used in patients with GA, and critically examine their ability to detect and quantify visual deficits. Conclusion Ophthalmologists and retina specialists now have a wide range of assessments available for the functional and anatomic characterization of GA in patients with AMD. To date, studies have been limited by their unimodal approach and we recommend that future studies of GA use multimodal imaging. We also suggest strategies for the optimal functional testing of patients with GA. PMID:27652913
Linda M. Haugen; Garrett L. Beier; Susan E. Bentz; Raymond P. Guries; James M. Slavicek
2017-01-01
A variety of methods have been used by different research groups to "challenge" inoculate American elms (Ulmus americana) with the purpose of determining whether some clones may be resistant to the Dutch elm disease fungus. The methods used by seven research groups are described, along with observations on complications and benefits...
National audit of continence care: laying the foundation.
Mian, Sarah; Wagg, Adrian; Irwin, Penny; Lowe, Derek; Potter, Jonathan; Pearson, Michael
2005-12-01
National audit provides a basis for establishing performance against national standards, benchmarking against other service providers and improving standards of care. For effective audit, clinical indicators are required that are valid, feasible to apply and reliable. This study describes the methods used to develop clinical indicators of continence care in preparation for a national audit. To describe the methods used to develop and test clinical indicators of continence care with regard to validity, feasibility and reliability. A multidisciplinary working group developed clinical indicators that measured the structure, process and outcome of care as well as case-mix variables. Literature searching, consensus workshops and a Delphi process were used to develop the indicators. The indicators were tested in 15 secondary care sites, 15 primary care sites and 15 long-term care settings. The process of development produced indicators that received a high degree of consensus within the Delphi process. Testing of the indicators demonstrated an internal reliability of 0.7 and an external reliability of 0.6. Data collection required significant investment in terms of staff time and training. The method used produced indicators that achieved a high degree of acceptance from health care professionals. The reliability of data collection was high for this audit and was similar to the level seen in other successful national audits. Data collection for the indicators was feasible to collect, however, issues of time and staffing were identified as limitations to such data collection. The study has described a systematic method for developing clinical indicators for national audit. The indicators proved robust and reliable in primary and secondary care as well as long-term care settings.
DOT National Transportation Integrated Search
2005-05-01
This report provides an overview of polymer flammability from a material science perspective and describes currently accepted test methods to quantify burning behavior. Simplifying assumptions about the gas and condensed phase processes of flaming co...
Conceptual design of a Bitter-magnet toroidal-field system for the ZEPHYR Ignition Test Reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, J.E.C.; Becker, H.D.; Bobrov, E.S.
1981-05-01
The following problems are described and discussed: (1) parametric studies - these studies examine among other things the interdependence of throat stresses, plasma parameters (margins of ignition) and stored energy. The latter is a measure of cost and is minimized in the present design; (2) magnet configuration - the shape of the plates are considered in detail including standard turns, turns located at beam ports, diagnostic and closure flanges; (3) ripple computation - this section describes the codes by which ripple is computed; (4) field diffusion and nuclear heating - the effect of magnetic field diffusion on heating is consideredmore » along with neutron heating. Current, field and temperature profiles are computed; (5) finite element analysis - the two and three dimensional finite element codes are described and the results discussed in detail; (6) structures engineering - this considers the calculation of critical stresses due to toroidal and overturning forces and discusses the method of constraint of these forces. The Materials Testing Program is also discussed; (7) fabrication - the methods available for the manufacture of the constituent parts of the Bitter plates, the method of assembly and remote maintenance are summarized.« less
Substantiation Data for Advanced Beaded and Tubular Structural Panels. Volume 3: Testing
NASA Technical Reports Server (NTRS)
Hedges, P. C.; Greene, B. E.
1974-01-01
The test program is described, which was conducted to provide the necessary experimental data to verify the design and analysis methods developed for beaded and tubular panels. Test results are summarized and presented for all local buckling and full size panel tests. Selected representative test data from each of these tests is presented in detail. The results of this program established a valid analysis and design procedure for circular tube panels. Test results from three other configurations show deformational modes which are not adequately accounted for in the present analyses.
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
Murad, Havi; Kipnis, Victor; Freedman, Laurence S
2016-10-01
Assessing interactions in linear regression models when covariates have measurement error (ME) is complex.We previously described regression calibration (RC) methods that yield consistent estimators and standard errors for interaction coefficients of normally distributed covariates having classical ME. Here we extend normal based RC (NBRC) and linear RC (LRC) methods to a non-classical ME model, and describe more efficient versions that combine estimates from the main study and internal sub-study. We apply these methods to data from the Observing Protein and Energy Nutrition (OPEN) study. Using simulations we show that (i) for normally distributed covariates efficient NBRC and LRC were nearly unbiased and performed well with sub-study size ≥200; (ii) efficient NBRC had lower MSE than efficient LRC; (iii) the naïve test for a single interaction had type I error probability close to the nominal significance level, whereas efficient NBRC and LRC were slightly anti-conservative but more powerful; (iv) for markedly non-normal covariates, efficient LRC yielded less biased estimators with smaller variance than efficient NBRC. Our simulations suggest that it is preferable to use: (i) efficient NBRC for estimating and testing interaction effects of normally distributed covariates and (ii) efficient LRC for estimating and testing interactions for markedly non-normal covariates. © The Author(s) 2013.
Shear Lag in Box Beams Methods of Analysis and Experimental Investigations
NASA Technical Reports Server (NTRS)
Kuhn, Paul; Chiarito, Patrick T
1942-01-01
The bending stresses in the covers of box beams or wide-flange beams differ appreciably from the stresses predicted by the ordinary bending theory on account of shear deformation of the flanges. The problem of predicting these differences has become known as the shear-lag problem. The first part of this paper deals with methods of shear-lag analysis suitable for practical use. The second part of the paper describes strain-gage tests made by the NACA to verify the theory. Three tests published by other investigators are also analyzed by the proposed method. The third part of the paper gives numerical examples illustrating the methods of analysis. An appendix gives comparisons with other methods, particularly with the method of Ebner and Koller.
Using Item Response Theory to Describe the Nonverbal Literacy Assessment (NVLA)
ERIC Educational Resources Information Center
Fleming, Danielle; Wilson, Mark; Ahlgrim-Delzell, Lynn
2018-01-01
The Nonverbal Literacy Assessment (NVLA) is a literacy assessment designed for students with significant intellectual disabilities. The 218-item test was initially examined using confirmatory factor analysis. This method showed that the test worked as expected, but the items loaded onto a single factor. This article uses item response theory to…
40 CFR 1048.515 - What are the field-testing procedures?
Code of Federal Regulations, 2010 CFR
2010-07-01
... CFR part 1065, subpart J, we describe the equipment and sampling methods for testing engines in the... specify in § 1048.101(c) for any continuous sampling period of at least 120 seconds under the following ranges of operation and operating conditions: (1) Engine operation during the emission sampling period...
Medical microbiological analysis of Apollo-Soyuz test project crewmembers
NASA Technical Reports Server (NTRS)
Taylor, G. R.; Zaloguev, S. N.
1976-01-01
The procedures and results of the Microbial Exchange Experiment (AR-002) of the Apollo-Soyuz Test Project are described. Included in the discussion of procedural aspects are methods and materials, in-flight microbial specimen collection, and preliminary analysis of microbial specimens. Medically important microorganisms recovered from both Apollo and Soyuz crewmen are evaluated.
Forensic Toxicology: An Introduction.
Smith, Michael P; Bluth, Martin H
2016-12-01
This article presents an overview of forensic toxicology. The authors describe the three components that make up forensic toxicology: workplace drug testing, postmortem toxicology, and human performance toxicology. Also discussed are the specimens that are tested, the methods used, and how the results are interpreted in this particular discipline. Copyright © 2016 Elsevier Inc. All rights reserved.
A Tutorial on Multiple Testing: False Discovery Control
NASA Astrophysics Data System (ADS)
Chatelain, F.
2016-09-01
This paper presents an overview of criteria and methods in multiple testing, with an emphasis on the false discovery rate control. The popular Benjamini and Hochberg procedure is described. The rationale for this approach is explained through a simple Bayesian interpretation. Some state-of-the-art variations and extensions are also presented.
21 CFR 177.1330 - Ionomeric resins.
Code of Federal Regulations, 2010 CFR
2010-04-01
... adapting the in-container methods described in § 175.300(e) of this chapter. Copies of the material... availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register... the end of the exposure period, remove the test container or test cell from the oven, if any, and...
ERIC Educational Resources Information Center
Chang, J. C.; And Others
1986-01-01
Discusses a new program at the University of Michigan in hazardous waste management. Describes a laboratory demonstration that deals with the reactivity and potential violence of several reactions that may be encountered on a hazardous waste site. Provides criteria for selecting particular compatibility testing methods. (TW)
American College Health Association Annual Pap Test and Sexually Transmitted Infection Survey: 2006
ERIC Educational Resources Information Center
Smith, P. Davis; Roberts, Craig M.
2009-01-01
Objective: The authors describe the cervical cytology and sexually transmitted infection (STI) testing patterns of US college health centers. Participants and Methods: A total of 128 self-selected US college health centers--representing more than 2 million college students--completed an online survey during February and March 2007. Results: Almost…
ERIC Educational Resources Information Center
Hall, William J.
2016-01-01
This article describes the development and preliminary validation of the Bullying, Harassment, and Aggression Receipt Measure (BullyHARM). The development of the BullyHARM involved a number of steps and methods, including a literature review, expert review, cognitive testing, readability testing, data collection from a large sample, reliability…
Helping Lower Secondary Students Develop Conceptual Understanding of Electrostatic Forces
ERIC Educational Resources Information Center
Moynihan, Richard; van Kampen, Paul; Finlayson, Odilla; McLoughlin, Eilish
2016-01-01
This article describes the development of a lesson sequence that supports secondary-level students to construct an explanatory model for electrostatic attraction using a guided enquiry method. The students examine electrostatic interactions at a macro level and explain the phenomena at the atomic level. Pre-tests, post-tests, homework assignments…
NASA Technical Reports Server (NTRS)
Rango, A.
1978-01-01
Major snow zones of the western U.S. were selected to test the capability of satellite systems for mapping snowcover in various snow, cloud, climatic, and vegetation regimes. Different satellite snowcover analysis methods used in each area are described along with results.
Using the Power Balance Wristband to Improve Students' Research-Design Skills
ERIC Educational Resources Information Center
Lawson, Timothy J.; Blackhart, Ginette C.; Gialopsos, Brooke M.
2016-01-01
We describe an exercise involving the power balance wristband (PBW) designed to enhance students' ability to design scientific tests. An instructor demonstrated that the PBW improved a student's balance, strength, and flexibility and invited students to design and conduct a brief scientific test of the PBW. Research methods students who…
Rapid Ascent Simulation at NASA-MSFC
NASA Technical Reports Server (NTRS)
Sisco, Jimmy D.
2004-01-01
The Environmental Test Facility (ETF), located at NASA-Marshall Space Flight Center, Huntsville, Alabama, has provided thermal vacuum testing for several major programs since the 1960's. The ETF consists of over 13 thermal vacuum chambers sized and configured to handle the majority of test payloads. The majority of tests require a hard vacuum with heating and cryogenics. NASA's Return-to-Flight program requested testing to simulate a launch from the ground to flight using vacuum, heating and cryogenics. This paper describes an effective method for simulating a launch.
New Tools to Prepare ACE Cross-section Files for MCNP Analytic Test Problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Forrest B.
Monte Carlo calculations using one-group cross sections, multigroup cross sections, or simple continuous energy cross sections are often used to: (1) verify production codes against known analytical solutions, (2) verify new methods and algorithms that do not involve detailed collision physics, (3) compare Monte Carlo calculation methods with deterministic methods, and (4) teach fundamentals to students. In this work we describe 2 new tools for preparing the ACE cross-section files to be used by MCNP ® for these analytic test problems, simple_ace.pl and simple_ace_mg.pl.
New pharmacokinetic methods. III. Two simple test for deep pool effect
DOE Office of Scientific and Technical Information (OSTI.GOV)
Browne, T.R.; Greenblatt, D.J.; Schumacher, G.E.
1990-08-01
If a portion of administered drug is distributed into a deep peripheral compartment, the drug's actual elimination half-life during the terminal exponential phase of elimination may be longer than determined by a single dose study or a tracer dose study (deep pool effect). Two simple methods of testing for deep pool effect applicable to drugs with either linear or nonlinear pharmacokinetic properties are described. The methods are illustrated with stable isotope labeled (13C15N2) tracer dose studies of phenytoin. No significant (P less than .05) deep pool effect was detected.
Viscoelastic material inversion using Sierra-SD and ROL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walsh, Timothy; Aquino, Wilkins; Ridzal, Denis
2014-11-01
In this report we derive frequency-domain methods for inverse characterization of the constitutive parameters of viscoelastic materials. The inverse problem is cast in a PDE-constrained optimization framework with efficient computation of gradients and Hessian vector products through matrix free operations. The abstract optimization operators for first and second derivatives are derived from first principles. Various methods from the Rapid Optimization Library (ROL) are tested on the viscoelastic inversion problem. The methods described herein are applied to compute the viscoelastic bulk and shear moduli of a foam block model, which was recently used in experimental testing for viscoelastic property characterization.
Methodology to improve design of accelerated life tests in civil engineering projects.
Lin, Jing; Yuan, Yongbo; Zhou, Jilai; Gao, Jie
2014-01-01
For reliability testing an Energy Expansion Tree (EET) and a companion Energy Function Model (EFM) are proposed and described in this paper. Different from conventional approaches, the EET provides a more comprehensive and objective way to systematically identify external energy factors affecting reliability. The EFM introduces energy loss into a traditional Function Model to identify internal energy sources affecting reliability. The combination creates a sound way to enumerate the energies to which a system may be exposed during its lifetime. We input these energies into planning an accelerated life test, a Multi Environment Over Stress Test. The test objective is to discover weak links and interactions among the system and the energies to which it is exposed, and design them out. As an example, the methods are applied to the pipe in subsea pipeline. However, they can be widely used in other civil engineering industries as well. The proposed method is compared with current methods.
Development of a test method against hot alkaline chemical splashes.
Mäkinen, Helena; Nieminen, Kalevi; Mäki, Susanna; Siiskonen, Sirkku
2008-01-01
High temperature alkaline chemical liquids have caused injuries and hazardous situations in Finnish pulp manufacturing mills. There are no requirements and/or test method standards concerning protection against high temperature alkaline chemical splashes. This paper describes the test method development process to test and identify materials appropriate for hot liquid chemical hazard protection. In the first phase, the liquid was spilled through a stainless steel funnel and the protection performance was evaluated using a polyvinyl chloride (PVC) film under the test material. After several tentative improvements, a graphite crucible was used for heating and spilling the chemical, and a copper-coated K-type thermometer with 4 independent measuring areas was designed to measure the temperature under the material samples. The thermometer was designed to respond quickly so that peak temperatures could be measured. The main problem was to keep the spilled amount of chemical constant, which unfortunately resulted in significant variability in data.
Spielmann, Horst; Grune, Barbara; Liebsch, Manfred; Seiler, Andrea; Vogel, Richard
2008-06-01
A short description of the history of the 3Rs concept is given, which was developed as the scientific concept to refine, reduce and replace animal experiments by Russel and Burch more than 40 years ago. In addition, the legal framework in Europe for developing alternatives to animal experiments is given and the current status of in vitro systems in pharmacology and toxicology is described including an update on metabolising systems. The decrease in experimental animal numbers during the past decade in Europe is illustrated by the situation in Germany and the contribution of international harmonisation of test guidelines on reducing animal numbers in regulatory testing is described. A review of the development of the principles of experimental validation is given and the 3T3 NRU in vitro phototoxicity test is used as an example for a successful validation study, which led to the acceptance of the first in vitro toxicity test for regulatory purposes by the OECD. Finally, the currently accepted alternative methods for standardisation and safety testing of drugs, biologicals and medical devices are summarised.
Dimension from covariance matrices.
Carroll, T L; Byers, J M
2017-02-01
We describe a method to estimate embedding dimension from a time series. This method includes an estimate of the probability that the dimension estimate is valid. Such validity estimates are not common in algorithms for calculating the properties of dynamical systems. The algorithm described here compares the eigenvalues of covariance matrices created from an embedded signal to the eigenvalues for a covariance matrix of a Gaussian random process with the same dimension and number of points. A statistical test gives the probability that the eigenvalues for the embedded signal did not come from the Gaussian random process.
21 CFR 606.65 - Supplies and reagents.
Code of Federal Regulations, 2014 CFR
2014-04-01
... solutions shall be tested on a regularly scheduled basis by methods described in the Standard Operating Procedures Manual to determine their capacity to perform as required: Reagent or solution Frequency of...
21 CFR 606.65 - Supplies and reagents.
Code of Federal Regulations, 2012 CFR
2012-04-01
... solutions shall be tested on a regularly scheduled basis by methods described in the Standard Operating Procedures Manual to determine their capacity to perform as required: Reagent or solution Frequency of...
21 CFR 606.65 - Supplies and reagents.
Code of Federal Regulations, 2013 CFR
2013-04-01
... solutions shall be tested on a regularly scheduled basis by methods described in the Standard Operating Procedures Manual to determine their capacity to perform as required: Reagent or solution Frequency of...
21 CFR 606.65 - Supplies and reagents.
Code of Federal Regulations, 2011 CFR
2011-04-01
... solutions shall be tested on a regularly scheduled basis by methods described in the Standard Operating Procedures Manual to determine their capacity to perform as required: Reagent or solution Frequency of...
Wing Download Results from a Test of a 0.658-Scale V-22 Rotor and Wing
NASA Technical Reports Server (NTRS)
Felker, Fort F.
1992-01-01
A test of a 0.658-scale V-22 rotor and wing was conducted in the 40 x 80 Foot Wind Tunnel at Ames Research Center. One of the principal objectives of the test was to measure the wing download in hover for a variety of test configurations. The wing download and surface pressures were measured for a wide range of thrust coefficients, with five different flap angles, two nacelle angles, and both directions or rotor rotation. This paper presents these results, and describes a new method for interpreting wing surface pressure data in hover. This method shows that the wing flap can produce substantial lift loads in hover.
Parrish, Rudolph S.; Smith, Charles N.
1990-01-01
A quantitative method is described for testing whether model predictions fall within a specified factor of true values. The technique is based on classical theory for confidence regions on unknown population parameters and can be related to hypothesis testing in both univariate and multivariate situations. A capability index is defined that can be used as a measure of predictive capability of a model, and its properties are discussed. The testing approach and the capability index should facilitate model validation efforts and permit comparisons among competing models. An example is given for a pesticide leaching model that predicts chemical concentrations in the soil profile.
Evaluation of new aquatic toxicity test methods for oil dispersants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pace, C.B.; Clark, J.R.; Bragin, G.E.
1994-12-31
Current aquatic toxicity test methods used for dispersant registration do not address real world exposure scenarios. Current test methods require 48 or 96 hour constant exposure conditions. In contrast, environmentally realistic exposures can be described as a pulse in which the initial concentration declines over time. Recent research using a specially designed testing apparatus (the California system) has demonstrated that exposure to Corexit 9527{reg_sign} under pulsed exposure conditions may be 3 to 22 times less toxic compared to continuous exposure scenarios. The objectives of this study were to compare results of toxicity tests using the California test system to resultsmore » from standardized tests, evaluate sensitivity of regional (Holmesimysis cast and Atherinops affinis) vs. standard test species (Mysidopsis bahia and Menidia beryllina) and determine if tests using the California test system and method are reproducible. All tests were conducted using Corexit 9527{reg_sign} as the test material. Standard toxicity tests conducted with M. bahia and H. cast resulted in LC50s similar to those from tests using the California apparatus. LC50s from tests conducted in the authors` laboratory with the California system and standard test species were within a factor of 2 to 6 of data previously reported for west coast species. Results of tests conducted with H. cast in the laboratory compared favorably to data reported by Singer et al. 1991.« less
Concept definition study for an extremely large aerophysics range facility
NASA Technical Reports Server (NTRS)
Swift, Hallock F.
1993-01-01
A conceptual design of a very large aeroballistic range is presented, as are its operational characteristics and procedures. The proposed model launcher is a two-stage light-gas gun, having a launch tube diameter of 254 mm, and the capability of accelerating a 14 kg launch mass to 6.1 km/sec. The gun's 91.4 cm diameter piston is driven by pressurized helium. High pressures in the central breech are contained by a multiple disk arrangement. The blast tank and sabot separation tank are described, as are methods for arresting sabot segments. The conceptual design of the range itself includes a 3.3 m diameter test or flight chamber some 330 m in length. Provisions are made for testing of free flight models and tests in which the model is confined by a track system. Methods for model deceleration and recovery are described. Provisions required for future addition of advanced model launchers such as an electromagnetic launcher or ram accelerator are addressed. Siting and safety issues are also addressed.
Environmentally safe aviation fuels
NASA Technical Reports Server (NTRS)
Liberio, Patricia D.
1995-01-01
In response to the Air Force directive to remove Ozone Depleting Chemicals (ODC's) from military specifications and Defense Logistics Agency's Hazardous Waste Minimization Program, we are faced with how to ensure a quality aviation fuel without using such chemicals. Many of these chemicals are found throughout the fuel and fuel related military specifications and are part of test methods that help qualify the properties and quality of the fuels before they are procured. Many years ago there was a directive for military specifications to use commercially standard test methods in order to provide standard testing in private industry and government. As a result the test methods used in military specifications are governed by the American Society of Testing and Materials (ASTM). The Air Force has been very proactive in the removal or replacement of the ODC's and hazardous materials in these test methods. For example, ASTM D3703 (Standard Test Method for Peroxide Number of Aviation Turbine Fuels), requires the use of Freon 113, a known ODC. A new rapid, portable hydroperoxide test for jet fuels similar to ASTM D3703 that does not require the use of ODC's has been developed. This test has proved, in limited testing, to be a viable substitute method for ASTM D3703. The Air Force is currently conducting a round robin to allow the method to be accepted by ASTM and therefore replace the current method. This paper will describe the Air Force's initiatives to remove ODC's and hazardous materials from the fuel and fuel related military specifications that the Air Force Wright Laboratory.
Detection of soy proteins in processed foods: literature overview and new experimental work.
Koppelman, Stef J; Lakemond, Catriona M M; Vlooswijk, Riek; Hefle, Susan L
2004-01-01
Several tests for the detection of soy proteins in foods have been described in the literature, and some are commercially available. This article gives an overview of these methods and discusses the advantages and disadvantages of each individual method. Based on the conclusions of this inventory, an experimental approach was designed to improve the sensitivity of measuring soy protein in processed foods. The aimed sensitivity is 10 ppm (10 microg soy protein in 1 g solid sample), which is over 100-fold lower than presently available tests. The aimed sensitivity is this low because levels of food allergens at 10 ppm and above may provoke reactions in food allergic persons. Native soybean meal, soy protein isolate, soy protein concentrate, and textured soy flakes were used as test materials. Several extraction procedures were compared and a new method using high pH was selected. Polyclonal antibodies were raised in rabbits and goats, and immunopurified antibodies were used in sandwich and inhibition enzyme-linked immunosorbent assay (ELISA). Extraction at pH 12 resulted in good yields for all tested samples, both quantitatively (Bradford) and qualitatively by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Immunopurified rabbit antibodies against this extract used in a competition ELISA format resulted in a sensitive test with a detection limit of 0.02 microg/mL, corresponding to 0.4 microg/g (0.4 ppm) in food samples. Cross-reactivity with some main food ingredients was measured and appeared to be negative in all cases. The presently developed test is applicable for soy ingredients and soy-containing foods that are processed in different ways. The limit of quantitation is 1 ppm, which is an enormous improvement over earlier described methods.
Joint inversion of hydraulic head and self-potential data associated with harmonic pumping tests
NASA Astrophysics Data System (ADS)
Soueid Ahmed, A.; Jardani, A.; Revil, A.; Dupont, J. P.
2016-09-01
Harmonic pumping tests consist in stimulating an aquifer by the means of hydraulic stimulations at some discrete frequencies. The inverse problem consisting in retrieving the hydraulic properties is inherently ill posed and is usually underdetermined when considering the number of well head data available in field conditions. To better constrain this inverse problem, we add self-potential data recorded at the ground surface to the head data. The self-potential method is a passive geophysical method. Its signals are generated by the groundwater flow through an electrokinetic coupling. We showed using a 3-D saturated unconfined synthetic aquifer that the self-potential method significantly improves the results of the harmonic hydraulic tomography. The hydroelectric forward problem is obtained by solving first the Richards equation, describing the groundwater flow, and then using the result in an electrical Poisson equation describing the self-potential problem. The joint inversion problem is solved using a reduction model based on the principal component geostatistical approach. In this method, the large prior covariance matrix is truncated and replaced by its low-rank approximation, allowing thus for notable computational time and storage savings. Three test cases are studied, to assess the validity of our approach. In the first test, we show that when the number of harmonic stimulations is low, combining the harmonic hydraulic and self-potential data does not improve the inversion results. In the second test where enough harmonic stimulations are performed, a significant improvement of the hydraulic parameters is observed. In the last synthetic test, we show that the electrical conductivity field required to invert the self-potential data can be determined with enough accuracy using an electrical resistivity tomography survey using the same electrodes configuration as used for the self-potential investigation.
NASA Technical Reports Server (NTRS)
Willsky, A. S.; Deyst, J. J.; Crawford, B. S.
1975-01-01
The paper describes two self-test procedures applied to the problem of estimating the biases in accelerometers and gyroscopes on an inertial platform. The first technique is the weighted sum-squared residual (WSSR) test, with which accelerator bias jumps are easily isolated, but gyro bias jumps are difficult to isolate. The WSSR method does not take full advantage of the knowledge of system dynamics. The other technique is a multiple hypothesis method developed by Buxbaum and Haddad (1969). It has the advantage of directly providing jump isolation information, but suffers from computational problems. It might be possible to use the WSSR to detect state jumps and then switch to the BH system for jump isolation and estimate compensation.
A procedure for testing the quality of LANDSAT atmospheric correction algorithms
NASA Technical Reports Server (NTRS)
Dias, L. A. V. (Principal Investigator); Vijaykumar, N. L.; Neto, G. C.
1982-01-01
There are two basic methods for testing the quality of an algorithm to minimize atmospheric effects on LANDSAT imagery: (1) test the results a posteriori, using ground truth or control points; (2) use a method based on image data plus estimation of additional ground and/or atmospheric parameters. A procedure based on the second method is described. In order to select the parameters, initially the image contrast is examined for a series of parameter combinations. The contrast improves for better corrections. In addition the correlation coefficient between two subimages, taken at different times, of the same scene is used for parameter's selection. The regions to be correlated should not have changed considerably in time. A few examples using this proposed procedure are presented.
Cutting force measurement of electrical jigsaw by strain gauges
NASA Astrophysics Data System (ADS)
Kazup, L.; Varadine Szarka, A.
2016-11-01
This paper describes a measuring method based on strain gauges for accurate specification of electric jigsaw's cutting force. The goal of the measurement is to provide an overall perspective about generated forces in a jigsaw's gearbox during a cutting period. The lifetime of the tool is affected by these forces primarily. This analysis is part of the research and development project aiming to develop a special linear magnetic brake for realizing automatic lifetime tests of electric jigsaws or similar handheld tools. The accurate specification of cutting force facilitates to define realistic test cycles during the automatic lifetime test. The accuracy and precision resulted by the well described cutting force characteristic and the possibility of automation provide new dimension for lifetime testing of the handheld tools with alternating movement.
Wang, D Z; Wang, C; Shen, C F; Zhang, Y; Zhang, H; Song, G D; Xue, X D; Xu, Z L; Zhang, S; Jiang, G H
2017-05-10
We described the time trend of acute myocardial infarction (AMI) from 1999 to 2013 in Tianjin incidence rate with Cochran-Armitage trend (CAT) test and linear regression analysis, and the results were compared. Based on actual population, CAT test had much stronger statistical power than linear regression analysis for both overall incidence trend and age specific incidence trend (Cochran-Armitage trend P value
Accelerated Testing of Polymeric Composites Using the Dynamic Mechanical Analyzer
NASA Technical Reports Server (NTRS)
Abdel-Magid, Becky M.; Gates, Thomas S.
2000-01-01
Creep properties of IM7/K3B composite material were obtained using three accelerated test methods at elevated temperatures. Results of flexural creep tests using the dynamic mechanical analyzer (DMA) were compared with results of conventional tensile and compression creep tests. The procedures of the three test methods are described and the results are presented. Despite minor differences in the time shift factor of the creep compliance curves, the DMA results compared favorably with the results from the tensile and compressive creep tests. Some insight is given into establishing correlations between creep compliance in flexure and creep compliance in tension and compression. It is shown that with careful consideration of the limitations of flexure creep, a viable and reliable accelerated test procedure can be developed using the DMA to obtain the viscoelastic properties of composites in extreme environments.
Measuring Thermal Conductivity at LH2 Temperatures
NASA Technical Reports Server (NTRS)
Selvidge, Shawn; Watwood, Michael C.
2004-01-01
For many years, the National Institute of Standards and Technology (NIST) produced reference materials for materials testing. One such reference material was intended for use with a guarded hot plate apparatus designed to meet the requirements of ASTM C177-97, "Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus." This apparatus can be used to test materials in various gaseous environments from atmospheric pressure to a vacuum. It allows the thermal transmission properties of insulating materials to be measured from just above ambient temperature down to temperatures below liquid hydrogen. However, NIST did not generate data below 77 K temperature for the reference material in question. This paper describes a test method used at NASA's Marshall Space Flight Center (MSFC) to optimize thermal conductivity measurements during the development of thermal protection systems. The test method extends the usability range of this reference material by generating data at temperatures lower than 77 K. Information provided by this test is discussed, as are the capabilities of the MSFC Hydrogen Test Facility, where advanced methods for materials testing are routinely developed and optimized in support of aerospace applications.
NASA Astrophysics Data System (ADS)
Ola, Max; Thomas, Christiane; Hesse, Ullrich
2017-08-01
Compressor performance test procedures are defined by the standard DIN EN 13771, wherein a variety of possible calorimeter and flow rate measurement methods are suggested. One option is the selection of two independent measurement methods. The accuracies of both selected measurement methods are essential. The second option requires only one method. However the measurement accuracy of the used device has to be verified and recalibrated on a regular basis. The compressor performance test facility at the Technische Universitaet Dresden uses a calibrated flow measurement sensor, a hot gas bypass and a mixed flow heat exchanger. The test bench can easily be modified for tests of various compressor types at different operating ranges and with various refrigerants. In addition, the modified test setup enables the investigation of long term liquid slug and its effects on the compressor. The modification comprises observational components, adjustments of the control system, safety measures and a customized oil recirculation system for compressors which do not contain an integrated oil sump or oil level regulation system. This paper describes the setup of the test bench, its functional principle, the key modifications, first test results and an evaluation of the energy balance.
Ballistic Resistance of Armored Passenger Vehicles: Test Protocols and Quality Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffrey M. Lacy; Robert E. Polk
2005-07-01
This guide establishes a test methodology for determining the overall ballistic resistance of the passenger compartment of assembled nontactical armored passenger vehicles (APVs). Because ballistic testing of every piece of every component of an armored vehicle is impractical, if not impossible, this guide describes a testing scheme based on statistical sampling of exposed component surface areas. Results from the test of the sampled points are combined to form a test score that reflects the probability of ballistic penetration into the passenger compartment of the vehicle.
The Design of Software for Three-Phase Induction Motor Test System
NASA Astrophysics Data System (ADS)
Haixiang, Xu; Fengqi, Wu; Jiai, Xue
2017-11-01
The design and development of control system software is important to three-phase induction motor test equipment, which needs to be completely familiar with the test process and the control procedure of test equipment. In this paper, the software is developed according to the national standard (GB/T1032-2005) about three-phase induction motor test method by VB language. The control system and data analysis software and the implement about motor test system are described individually, which has the advantages of high automation and high accuracy.
The Model Analyst’s Toolkit: Scientific Model Development, Analysis, and Validation
2015-02-20
being integrated within MAT, including Granger causality. Granger causality tests whether a data series helps when predicting future values of another...relations by econometric models and cross-spectral methods. Econometrica: Journal of the Econometric Society, 424-438. Granger, C. W. (1980). Testing ... testing dataset. This effort is described in Section 3.2. 3.1. Improvements in Granger Causality User Interface Various metrics of causality are
Traveling-Wave Tube Cold-Test Circuit Optimization Using CST MICROWAVE STUDIO
NASA Technical Reports Server (NTRS)
Chevalier, Christine T.; Kory, Carol L.; Wilson, Jeffrey D.; Wintucky, Edwin G.; Dayton, James A., Jr.
2003-01-01
The internal optimizer of CST MICROWAVE STUDIO (MWS) was used along with an application-specific Visual Basic for Applications (VBA) script to develop a method to optimize traveling-wave tube (TWT) cold-test circuit performance. The optimization procedure allows simultaneous optimization of circuit specifications including on-axis interaction impedance, bandwidth or geometric limitations. The application of Microwave Studio to TWT cold-test circuit optimization is described.
Testa, Maria; Livingston, Jennifer A; VanZile-Tamsen, Carol
2011-02-01
A mixed methods approach, combining quantitative with qualitative data methods and analysis, offers a promising means of advancing the study of violence. Integrating semi-structured interviews and qualitative analysis into a quantitative program of research on women's sexual victimization has resulted in valuable scientific insight and generation of novel hypotheses for testing. This mixed methods approach is described and recommendations for integrating qualitative data into quantitative research are provided.
Development of an Interactive Social Media Tool for Parents with Concerns about Vaccines
ERIC Educational Resources Information Center
Shoup, Jo Ann; Wagner, Nicole M.; Kraus, Courtney R.; Narwaney, Komal J.; Goddard, Kristin S.; Glanz, Jason M.
2015-01-01
Objective: Describe a process for designing, building, and evaluating a theory-driven social media intervention tool to help reduce parental concerns about vaccination. Method: We developed an interactive web-based tool using quantitative and qualitative methods (e.g., survey, focus groups, individual interviews, and usability testing). Results:…
A method is described to discriminate between live and dead cells of the infectious fungi Aspergillus fumigatus, A. flavus, A. terreus, Mucor racemosus, Rhizopus stolonifer and Paecilomyces variotii. To test the method, conidial suspensions were heat inactivated at 85oC or held ...
Empirical Histograms in Item Response Theory with Ordinal Data
ERIC Educational Resources Information Center
Woods, Carol M.
2007-01-01
The purpose of this research is to describe, test, and illustrate a new implementation of the empirical histogram (EH) method for ordinal items. The EH method involves the estimation of item response model parameters simultaneously with the approximation of the distribution of the random latent variable (theta) as a histogram. Software for the EH…
This paper describes a study to test field methods for characterizing pesticide exposures to 20 farmworker children aged 5-27 months old living in the Salinas Valley of Monterey County, California. Methods for collecting house dust, indoor and outdoor air, dislodgeable residues ...
Radon Reduction Methods: A Homeowner's Guide.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC.
The U.S. Environmental Protection Agency (EPA) is studying the effectiveness of various ways to reduce high concentrations of radon in houses. This booklet was produced to share what has been learned with those whose radon problems demand immediate action. The booklet describes nine methods that have been tested successfully--by EPA and/or other…
Testing common stream sampling methods for broad-scale, long-term monitoring
Eric K. Archer; Brett B. Roper; Richard C. Henderson; Nick Bouwes; S. Chad Mellison; Jeffrey L. Kershner
2004-01-01
We evaluated sampling variability of stream habitat sampling methods used by the USDA Forest Service and the USDI Bureau of Land Management monitoring program for the upper Columbia River Basin. Three separate studies were conducted to describe the variability of individual measurement techniques, variability between crews, and temporal variation throughout the summer...
Acceleration of boundary element method for linear elasticity
NASA Astrophysics Data System (ADS)
Zapletal, Jan; Merta, Michal; Čermák, Martin
2017-07-01
In this work we describe the accelerated assembly of system matrices for the boundary element method using the Intel Xeon Phi coprocessors. We present a model problem, provide a brief overview of its discretization and acceleration of the system matrices assembly using the coprocessors, and test the accelerated version using a numerical benchmark.
Aerodynamic design using numerical optimization
NASA Technical Reports Server (NTRS)
Murman, E. M.; Chapman, G. T.
1983-01-01
The procedure of using numerical optimization methods coupled with computational fluid dynamic (CFD) codes for the development of an aerodynamic design is examined. Several approaches that replace wind tunnel tests, develop pressure distributions and derive designs, or fulfill preset design criteria are presented. The method of Aerodynamic Design by Numerical Optimization (ADNO) is described and illustrated with examples.
Formal Methods of V&V of Partial Specifications: An Experience Report
NASA Technical Reports Server (NTRS)
Easterbrook, Steve; Callahan, John
1997-01-01
This paper describes our work exploring the suitability of formal specification methods for independent verification and validation (IV&V) of software specifications for large, safety critical systems. An IV&V contractor often has to perform rapid analysis on incomplete specifications, with no control over how those specifications are represented. Lightweight formal methods show significant promise in this context, as they offer a way of uncovering major errors, without the burden of full proofs of correctness. We describe an experiment in the application of the method SCR. to testing for consistency properties of a partial model of requirements for Fault Detection Isolation and Recovery on the space station. We conclude that the insights gained from formalizing a specification is valuable, and it is the process of formalization, rather than the end product that is important. It was only necessary to build enough of the formal model to test the properties in which we were interested. Maintenance of fidelity between multiple representations of the same requirements (as they evolve) is still a problem, and deserves further study.
Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David
2015-01-01
New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc. 2015.