Sample records for detect minute amounts

  1. Standoff detection of trace amounts of solids by nonlinear Raman spectroscopy using shaped femtosecond pulses

    NASA Astrophysics Data System (ADS)

    Katz, O.; Natan, A.; Silberberg, Y.; Rosenwaks, S.

    2008-04-01

    We demonstrate a single-beam, standoff (>10m) detection and identification of various materials including minute amounts of explosives under ambient light conditions. This is obtained by multiplex coherent anti-Stokes Raman scattering spectroscopy (CARS) using a single femtosecond phase-shaped laser pulse. We exploit the strong nonresonant background for amplification of the backscattered resonant CARS signals by employing a homodyne detection scheme. The simple and highly sensitive spectroscopic technique has a potential for hazardous materials standoff detection applications.

  2. Nano-crystalline porous tin oxide film for carbon monoxide sensing

    NASA Technical Reports Server (NTRS)

    Liu, Chung-Chiun (Inventor); Savinell, Robert F. (Inventor); Jin, Zhihong (Inventor)

    2000-01-01

    A tin oxide sol is deposited on platinum electrodes (12) of a sensor (10). The sol is calcined at a temperature of 500 to 800.degree. C. to produce a thin film of tin oxide with a thickness of about 150 nm to 2 .mu. and having a nano-crystalline structure with good stability. The sensor rapidly detects reducing gases, such as carbon monoxide, or hydrocarbons and organic vapors. Sensors using films calcined at around 700.degree. C. have high carbon monoxide selectivity with a response time of around 4 minutes and a recovery time of 1 minute, and therefore provide good detection systems for detection of trace amounts of pollutants such as toxic and flammable gases in homes, industrial settings, and hospitals.

  3. Multiplex detection of pathogen biomarkers in human blood, serum, and saliva using silicon photonic microring resonators

    NASA Astrophysics Data System (ADS)

    Estrada, I. A.; Burlingame, R. W.; Wang, A. P.; Chawla, K.; Grove, T.; Wang, J.; Southern, S. O.; Iqbal, M.; Gunn, L. C.; Gleeson, M. A.

    2015-05-01

    Genalyte has developed a multiplex silicon photonic chip diagnostics platform (MaverickTM) for rapid detection of up to 32 biological analytes from a drop of sample in just 10 to 20 minutes. The chips are manufactured with waveguides adjacent to ring resonators, and probed with a continuously variable wavelength laser. A shift in the resonant wavelength as mass binds above the ring resonators is measured and is directly proportional to the amount of bound macromolecules. We present here the ability to multiplex the detection of hemorrhagic fever antigens in whole blood, serum, and saliva in a 16 minute assay. Our proof of concept testing of a multiplex antigencapture chip has the ability to detect Zaire Ebola (ZEBOV) recombinant soluble glycoprotein (rsGP), Marburg virus (MARV) Angola recombinant glycoprotein (rGP) and dengue nonstructural protein I (NS1). In parallel, detection of 2 malaria antigens has proven successful, but has yet to be incorporated into multiplex with the others. Each assay performs with sensitivity ranging from 1.6 ng/ml to 39 ng/ml depending on the antigen detected, and with minimal cross-reactivity.

  4. Preliminary Results of a New Type of Surface Property Measurement Ideal for a Future Mars Rover Mission

    NASA Technical Reports Server (NTRS)

    Buhler, C. R.; Calle, C. I.; Mantovani, J. G.; Buehler, M. G.; Nowicki, A. W.; Ritz, M.

    2004-01-01

    The success of the recent rover missions to Mars has stressed the importance of acquiring the maximum amount of geological information with the least amount of data possible. We have designed, tested and implemented special sensors mounted on a rover s wheel capable of detecting minute changes in surface topology thus eliminating the need for specially- made science platforms. These sensors, based on the previously designed, flight qualified Mars Environmental Compatibility Assessment (MECA) Electrometer, measure the static electricity (triboelectricity) generated between polymer materials and the Martian regolith during rover transverses. The sensors are capable of detecting physical changes in the soil that may not be detectable by other means, such as texture, size and moisture content. Although triboelectricity is a surface phenomenon, the weight of a rover will undoubtedly protrude the sensors below the dust covered layers, exposing underlying regolith whose properties may not be detectable through other means.

  5. Detection of dehydration by using volume kinetics.

    PubMed

    Zdolsek, Joachim; Li, Yuhong; Hahn, Robert G

    2012-10-01

    Patients admitted to surgery may be dehydrated, which is difficult to diagnose except when it is severe (>5% Gl116 of the body weight). We hypothesized that modest dehydration can be detected by kinetic analysis of the blood hemoglobin concentration after a bolus infusion of crystalloid fluid. Four series of experiments were performed on 10 conscious, healthy male volunteers. Separated by at least 2 days, they received 5 or 10 mL/kg acetated Ringer's solution over 15 minutes. Before starting half of the IV infusions, volume depletion amounting to 1.5 to 2.0 L (approximately 2% of body weight) was induced with furosemide. The elimination clearance and the half-life of the infused fluid were calculated based on blood hemoglobin over 120 minutes. The perfusion index and the pleth variability index were monitored by pulse oximetry after a change of body position. Dehydration decreased the elimination clearance of acetated Ringer's solution [median (25th-75th percentile)] from 1.84 (1.23-2.57) to 0.53 (0.41-0.79) mL/kg/min (Wilcoxon matched-pair test P < 0.001) and increased the half-life from 23 (12-37) to 76 (57-101) minutes (P < 0.001). The smaller infusion, 5 mL/kg, fully discriminated between experiments performed in the euhydrated and dehydrated states, whereas the urinary excretion provided a less-reliable indication of hydration status. Dehydration decreased the perfusion index but did not affect the pleth variability index. Dehydration amounting to 2% of the body weight could be detected from the elimination clearance and the half-life of an infusion of 5 mL/kg Ringer's solution.

  6. Vapor detection of trafficking of contraband money: A discussion of technical feasibility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dietz, R.N.

    1996-02-01

    For every two pounds of cocaine smuggled into the US, drug traffikers are being forced to clandestinely ship three pounds of money back out for subsequent laundering. Based on tracer technology developed for validation of long-range atmospheric transport models and other commercial applications, it is shown that US currency can be tagged with a minute amount (about 1 ppm by weight of a bill) of perfluorocharbon tracer (PFT) material that is sufficient to last for about 30 years and yet provide a vapor emission rate suitable for detectability of modest caches of contraband money in vehicles at border crossings, onmore » aircraft at international terminals, and in buildings. The cost of tagging is less than $5 per million bills; the taggant quantity should have no impact on the feel of a bill. The low emission rate would not allow detectability of usual amounts of money in typical scenarios, providing an essential degree of privacy, but extraordinary amounts would be detectable using specialized instrumentation and know-how not easily attainable but commercially in production; an example of sub-part-per-quadrillion detection of a proposed PFT taggant is demonstrated using a prototype commercial unit. An outline of a research and demonstration program to achieve this capability and details of the proposed tagging and detection procedures already indicate that the concept is technically feasible.« less

  7. Study on methenamine detection in starch products through SERS technology

    NASA Astrophysics Data System (ADS)

    Cui, Yu; Qu, Zhou

    2016-01-01

    Using silver sol as a strengthened base, this paper concludes that l0ppb-0.1ppb methenamine aqueous solution has a better signal in 1052cm-1 Raman feature. And the lower limit of the aqueous solution is about 0.1ppb. Adding corresponding amount methenamine in vermicelli sample, the lower limit is about 10ppm. This is a safest and pollution-free detection process. Furthermore, the pretreatment process is simple, which will be finished in 20 minutes. Hence, it is better than other detection methods. SERS technology provides a simple, rapid and efficient detection method for field measurement and real time detection modulating disk of component, laser zooming system. Through the use of laser diode, Laser-beam riding guided system is likely to have smaller shape and very light.

  8. Biomedical Applications of Micro-Raman and Surface-Enhanced Raman Scattering (SERS) Technology

    DTIC Science & Technology

    2012-10-01

    to be an effective media for PSA capture. For SERS-based immunoassays, nitrocellulose offers comparable results to those obtained using gold-coated...glass substrates while offering a more cost- effective and time-saving method of detecting minute amounts of PSA; (ii) Micro-Raman imaging...technology was found to be effective in chemical mapping of arteries in the tissues of a post mortem individual whose cause of death was a cardiac event

  9. Nitrogen dioxide vapor penetration of chlorobutyl rubber SCAPE under operational conditions

    NASA Technical Reports Server (NTRS)

    Schehl, T. A.; Beall, T. W.

    1980-01-01

    Operational self contained atmospheric protective ensembles (SCAPE suits) and fabric from the suits were subjected to a series of tests designed to determine the amount of exposure a wearer of the suit would receive if a spill of the hypergolic oxidizer nitrogen tetroxide (N2O4) should occur nearby. The results of these tests show that a wearer of a "stock" SCAPE suit equipped with a standard liquid air pack, if exposed to a spill resulting in a 26 percent increase of oxidizer in the surrounding atmosphere, will experiment no detectable concentration of nitrogen dioxide (NO2) inside the suit for 15 minutes. Thereafter, the NO2 concentration within the suit will increase for 35 minutes at a rate of 0.07 ppm per minute and then at a gradually decreasing rate until an equilibrium concentration of 3.4 ppm is attained after 100 minutes. Momentary increases of as much as 1.6 ppm can be expected if the wearer were to rise quickly from a squatting position, but the additional NO2 would be dissipated within three minutes. The effect of liquid and vapor N2O4 and of liquid monomethylhydrazine on permeation rates and tensile strength of the SCAPE suit fabric was also investigated.

  10. 37 CFR 255.3 - Adjustment of royalty rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... fraction thereof, whichever amount is larger, subject to further adjustment pursuant to paragraphs (b....85 cent per minute of playing time or fraction thereof, whichever amount is larger, subject to... embodied in the phonorecord shall be either 5.0 cents, or 0.95 cent per minute of playing time or fraction...

  11. Intracellular proteolysis of pancreatic zymogens.

    PubMed Central

    Gorelick, F. S.; Modlin, I. M.; Leach, S. D.; Carangelo, R.; Katz, M.

    1992-01-01

    Activation of pancreatic digestive zymogens within the pancreatic acinar cell may be an early event in the development of pancreatitis. To detect such activation, an immunoblot assay has been developed that measures the relative amounts of inactive zymogens and their respective active enzyme forms. Using this assay, high doses of cholecystokinin or carbachol were found to stimulate the intracellular conversion of at least three zymogens (procarboxypeptidase A1, procarboxypeptidase B, and chymotrypsinogen 2) to their active forms. Thus, this conversion may be a generalized phenomenon of pancreatic zymogens. The conversion is detected within ten minutes of treatment and is not associated with changes in acinar cell morphology; it has been predicted that the lysosomal thiol protease, cathepsin B, may initiate this conversion. Small amounts of cathepsin B are found in the secretory pathway, and cathepsin B can activate trypsinogen in vitro; however, exposure of acini to a thiol protease inhibitor (E64) did not block this conversion. Conversion was inhibited by the serine protease inhibitor, benzamidine, and by raising the intracellular pH, using chloroquine or monensin. This limited proteolytic conversion appears to require a low pH compartment and a serine protease activity. After long periods of treatment (60 minutes), the amounts of the active enzyme forms began to decrease; this observation suggested that the active enzyme forms were being degraded. Treatment of acini with E64 reduced this late decrease in active enzyme forms, suggesting that thiol proteases, including lysosomal hydrolases, may be involved in the degradation of the active enzyme forms. These findings indicate that pathways for zymogen activation as well as degradation of active enzyme forms are present within the pancreatic acinar cell. Images FIG. 1 FIG. 6 PMID:1340058

  12. Direct and long-term detection of gene doping in conventional blood samples.

    PubMed

    Beiter, T; Zimmermann, M; Fragasso, A; Hudemann, J; Niess, A M; Bitzer, M; Lauer, U M; Simon, P

    2011-03-01

    The misuse of somatic gene therapy for the purpose of enhancing athletic performance is perceived as a coming threat to the world of sports and categorized as 'gene doping'. This article describes a direct detection approach for gene doping that gives a clear yes-or-no answer based on the presence or absence of transgenic DNA in peripheral blood samples. By exploiting a priming strategy to specifically amplify intronless DNA sequences, we developed PCR protocols allowing the detection of very small amounts of transgenic DNA in genomic DNA samples to screen for six prime candidate genes. Our detection strategy was verified in a mouse model, giving positive signals from minute amounts (20 μl) of blood samples for up to 56 days following intramuscular adeno-associated virus-mediated gene transfer, one of the most likely candidate vector systems to be misused for gene doping. To make our detection strategy amenable for routine testing, we implemented a robust sample preparation and processing protocol that allows cost-efficient analysis of small human blood volumes (200 μl) with high specificity and reproducibility. The practicability and reliability of our detection strategy was validated by a screening approach including 327 blood samples taken from professional and recreational athletes under field conditions.

  13. Stand-off detection of explosive particles by imaging Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Nordberg, Markus; Åkeson, Madeleine; Östmark, Henric; Carlsson, Torgny E.

    2011-06-01

    A multispectral imaging technique has been developed to detect and identify explosive particles, e.g. from a fingerprint, at stand-off distances using Raman spectroscopy. When handling IED's as well as other explosive devices, residues can easily be transferred via fingerprints onto other surfaces e.g. car handles, gear sticks and suite cases. By imaging the surface using multispectral imaging Raman technique the explosive particles can be identified and displayed using color-coding. The technique has been demonstrated by detecting fingerprints containing significant amounts of 2,4-dinitrotoulene (DNT), 2,4,6-trinitrotoulene (TNT) and ammonium nitrate at a distance of 12 m in less than 90 seconds (22 images × 4 seconds)1. For each measurement, a sequence of images, one image for each wave number, is recorded. The spectral data from each pixel is compared with reference spectra of the substances to be detected. The pixels are marked with different colors corresponding to the detected substances in the fingerprint. The system has now been further developed to become less complex and thereby less sensitive to the environment such as temperature fluctuations. The optical resolution has been improved to less than 70 μm measured at 546 nm wavelength. The total detection time is ranging from less then one minute to around five minutes depending on the size of the particles and how confident the identification should be. The results indicate a great potential for multi-spectral imaging Raman spectroscopy as a stand-off technique for detection of single explosive particles.

  14. Sensors Provide Early Warning of Biological Threats

    NASA Technical Reports Server (NTRS)

    2009-01-01

    Early Warning Inc. of Troy, New York, licensed powerful biosensor technology from Ames Research Center. Incorporating carbon nanotubes tipped with single strands of nucleic acid from waterborne pathogens, the sensor can detect even minute amounts of targeted, disease causing bacteria, viruses, and parasites. Early Warning features the NASA biosensor in its water analyzer, which can provide advance alert of potential biological hazards in water used for agriculture, food and beverages, showers, and at beaches and lakes -- within hours instead of the days required by conventional laboratory methods.

  15. Minutes of the Explosives Safety Seminar (25th) Held in Anaheim, California on 18-20 August 1992. Volume 1

    DTIC Science & Technology

    1992-08-20

    project. There is no doubt that we would have otherwise spent many years in proving project feasibility and trialing the specific demilitarisation...SUCH ROCKET MOTORS AS THE ONE USED IN THE BULLPUP SYSTEM WERE CONSIDERED. A. DRAINING AND NEUTRALIZING THE OXIDIZER BY CAUSTIC SODA AND THEN SIMPLE...INHIBITED RED FUMING NITRIC ACID WAS DETECTED IN SMALL AMOUNTS. 482 CONSEQUENTLY. THE "EMPTY" CASES WERE PLACED INTO A TANK CONTAINING WATER AND CAUSTIC

  16. Computation of the Transmitted and Polarized Scattered Fluxes by the Exoplanet HD 189733b in X-Rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marin, Frédéric; Grosso, Nicolas, E-mail: frederic.marin@astro.unistra.fr

    2017-02-01

    Thousands of exoplanets have been detected, but only one exoplanetary transit was potentially observed in X-rays from HD 189733A. What makes the detection of exoplanets so difficult in this band? To answer this question, we run Monte-Carlo radiative transfer simulations to estimate the amount of X-ray flux reprocessed by HD 189733b. Despite its extended evaporating atmosphere, we find that the X-ray absorption radius of HD 189733b at 0.7 keV, which is the mean energy of the photons detected in the 0.25–2 keV energy band by XMM-Newton , is ∼1.01 times the planetary radius for an atmosphere of atomic hydrogen andmore » helium (including ions), and produces a maximum depth of ∼2.1% at ∼±46 minutes from the center of the planetary transit on the geometrically thick and optically thin corona. We compute numerically in the 0.25–2 keV energy band that this maximum depth is only of ∼1.6% at ∼±47 minutes from the transit center, and not very sensitive to the metal abundance, assuming that adding metals in the atmosphere would not dramatically change the density–temperature profile. Regarding a direct detection of HD 189733b in X-rays, we find that the amount of flux reprocessed by the exoplanetary atmosphere varies with the orbital phase, spanning between three and five orders of magnitude fainter than the flux of the primary star. Additionally, the degree of linear polarization emerging from HD 189733b is <0.003%, with maximums detected near planetary greatest elongations. This implies that both the modulation of the X-ray flux with the orbital phase and the scatter-induced continuum polarization cannot be observed with current X-ray facilities.« less

  17. Odor Landscapes in Turbulent Environments

    NASA Astrophysics Data System (ADS)

    Celani, Antonio; Villermaux, Emmanuel; Vergassola, Massimo

    2014-10-01

    The olfactory system of male moths is exquisitely sensitive to pheromones emitted by females and transported in the environment by atmospheric turbulence. Moths respond to minute amounts of pheromones, and their behavior is sensitive to the fine-scale structure of turbulent plumes where pheromone concentration is detectible. The signal of pheromone whiffs is qualitatively known to be intermittent, yet quantitative characterization of its statistical properties is lacking. This challenging fluid dynamics problem is also relevant for entomology, neurobiology, and the technological design of olfactory stimulators aimed at reproducing physiological odor signals in well-controlled laboratory conditions. Here, we develop a Lagrangian approach to the transport of pheromones by turbulent flows and exploit it to predict the statistics of odor detection during olfactory searches. The theory yields explicit probability distributions for the intensity and the duration of pheromone detections, as well as their spacing in time. Predictions are favorably tested by using numerical simulations, laboratory experiments, and field data for the atmospheric surface layer. The resulting signal of odor detections lends itself to implementation with state-of-the-art technologies and quantifies the amount and the type of information that male moths can exploit during olfactory searches.

  18. The analysis of the possibility of using 10-minute rainfall series to determine the maximum rainfall amount with 5 minutes duration

    NASA Astrophysics Data System (ADS)

    Kaźmierczak, Bartosz; Wartalska, Katarzyna; Wdowikowski, Marcin; Kotowski, Andrzej

    2017-11-01

    Modern scientific research in the area of heavy rainfall analysis regarding to the sewerage design indicates the need to develop and use probabilistic rain models. One of the issues that remains to be resolved is the length of the shortest amount of rain to be analyzed. It is commonly believed that the best time is 5 minutes, while the least rain duration measured by the national services is often 10 or even 15 minutes. Main aim of this paper is to present the difference between probabilistic rainfall models results given from rainfall time series including and excluding 5 minutes rainfall duration. Analysis were made for long-time period from 1961-2010 on polish meteorological station Legnica. To develop best fitted to measurement rainfall data probabilistic model 4 probabilistic distributions were used. Results clearly indicates that models including 5 minutes rainfall duration remains more appropriate to use.

  19. Feasibility study of mid-infrared absorption spectroscopy using electrospray ionization

    NASA Astrophysics Data System (ADS)

    Ahmed, Tahsin; Foster, Erick; Bohn, Paul; Howard, Scott

    2016-09-01

    Precise detection of trace amount of molecules, such as the disease biomarkers present in biofluids or explosive residues, requires high sensitivity detection. electrospray ionization-mass spectrometry (ESI-MS) is a common and effective technique for sensitive trace molecular detection in small-volume liquid samples. In ESI-MS, nano-liter volume samples are ionized and aerosolized by ESI, and fed into MS for mass analysis. ESI-MS has proven to be a reliable ionization technique for coupling liquid phase separations like liquid chromatography (LC) and capillary zone electrophoresis (CE) with the highly specific resolving power of MS. While CE and ESI can be performed on a microfluidic chip having a footprint of a few cm2, MS is typically at least 100 times bigger in size than a micro-chip. A reduced size, weight, and power profile would enable semi-portable applications in forensics, environmental monitoring, defense, and biological/pharmaceutical applications. To achieve this goal, we present an initial study evaluating the use of mid-infrared absorption spectroscopy (MIRAS) in place of MS to create a ESI-MIRAS system. To establish feasibility, we perform ESI-MIRAS on phospholipid samples, which have been previously demonstrated to be separable by CE. Phospholipids are biomarkers of degenerative neurological, kidney, and bone diseases and can be found in biofluids such as blood, urine and cerebrospinal fluid. To establish sensitivity limits, calibration samples of 100 μM concentration are electrospray deposited on to a grounded Si wafer for different times (1 minutes to 4 minutes with a 1 minute step). The minimum detectable concentration-time product, where a FTIR globar is used as the MIR source, is found 200 μM·s.

  20. Does warming the breasts affect the amount of breastmilk production?

    PubMed

    Yiğit, Feride; Çiğdem, Zerrin; Temizsoy, Ebru; Cingi, Melek Ersoy; Korel, Özlem; Yıldırım, Egemen; Ovalı, Fahri

    2012-12-01

    Increasing the amount of breastmilk is vital for both the nursing mother and child. Warming up breasts before using electrical pumps to pump out breastmilk may help to increase the amount of breastmilk, especially in the mothers of babies who are being nursed in the neonatal intensive care unit. Thirty-nine mothers whose babies had been admitted to the neonatal intensive care unit were analyzed. A breast compress that was warmed up in a microwave oven for 1 minute at 180 W was applied to one of the breasts for 20 minutes, and both breasts were sucked by an electrical breast pump for 15 minutes. The amount of breastmilk after each procedure was recorded. The amount of breastmilk that was obtained from warmed breasts was significantly higher than that obtained from nonwarmed breasts (maximum, 47.02 ± 23.01 mL vs. 33.15 ± 19.98 mL) (p=0.000). Warming up breasts by a breast compress is easy and affordable, and this procedure increases the amount of breastmilk, thus facilitating infant nutrition and recovery especially in the neonatal intensive care unit.

  1. Open tubular lab-on-column/mass spectrometry for targeted proteomics of nanogram sample amounts.

    PubMed

    Hustoft, Hanne Kolsrud; Vehus, Tore; Brandtzaeg, Ole Kristian; Krauss, Stefan; Greibrokk, Tyge; Wilson, Steven Ray; Lundanes, Elsa

    2014-01-01

    A novel open tubular nanoproteomic platform featuring accelerated on-line protein digestion and high-resolution nano liquid chromatography mass spectrometry (LC-MS) has been developed. The platform features very narrow open tubular columns, and is hence particularly suited for limited sample amounts. For enzymatic digestion of proteins, samples are passed through a 20 µm inner diameter (ID) trypsin + endoproteinase Lys-C immobilized open tubular enzyme reactor (OTER). Resulting peptides are subsequently trapped on a monolithic pre-column and transferred on-line to a 10 µm ID porous layer open tubular (PLOT) liquid chromatography LC separation column. Wnt/ß-catenein signaling pathway (Wnt-pathway) proteins of potentially diagnostic value were digested+detected in targeted-MS/MS mode in small cell samples and tumor tissues within 120 minutes. For example, a potential biomarker Axin1 was identifiable in just 10 ng of sample (protein extract of ∼1,000 HCT15 colon cancer cells). In comprehensive mode, the current OTER-PLOT set-up could be used to identify approximately 1500 proteins in HCT15 cells using a relatively short digestion+detection cycle (240 minutes), outperforming previously reported on-line digestion/separation systems. The platform is fully automated utilizing common commercial instrumentation and parts, while the reactor and columns are simple to produce and have low carry-over. These initial results point to automated solutions for fast and very sensitive MS based proteomics, especially for samples of limited size.

  2. Reversal electron attachment ionizer for detection of trace species

    NASA Technical Reports Server (NTRS)

    Bernius, Mark T. (Inventor); Chutjian, Ara (Inventor)

    1990-01-01

    An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of said electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.

  3. Reversal electron attachment ionizer for detection of trace species

    NASA Technical Reports Server (NTRS)

    Bernius, Mark T. (Inventor); Chutjian, Ara (Inventor)

    1989-01-01

    An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of the electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.

  4. Diffusion of Antimicrobials Across Silicone Hydrogel Contact Lenses

    PubMed Central

    Zambelli, Alison M.; Brothers, Kimberly M.; Hunt, Kristin M.; Romanowski, Eric G.; Nau, Amy C.; Dhaliwal, Deepinder K.; Shanks, Robert M. Q.

    2014-01-01

    Objectives To measure the diffusion of topical preparations of moxifloxacin, amphotericin B (AmB), and polyhexamethylene biguanide (PHMB) through silicone hydrogel (SH) contact lenses in vitro. Methods Using an in vitro model, the diffusion of three antimicrobials through SH contact lenses was measured. Diffused compounds were measured using a spectrophotometer at set time points over a period of four hours. The amount of each diffused antimicrobial was determined by comparing the experimental value to a standard curve. A biological assay was performed to validate the contact lens diffusion assay by testing antimicrobial activity of diffused material against lawns of susceptible bacteria (Staphylococcus epidermidis) and yeast (Saccharomyces cerevisiae). Experiments were repeated at least two times with a total of at least 4 independent replicates. Results Our data show detectable moxifloxacin and PHMB diffusion through SH contact lenses at 30 minutes, while amphotericin B diffusion remained below the limit of detection within the 4 hour experimental period. In the biological assay, diffused moxifloxacin demonstrated microbial killing starting at 20 minutes on bacterial lawns, whereas PHMB and amphotericin B failed to demonstrate killing on microbial lawns over the course of the 60 minute experiment. Conclusions In vitro diffusion assays demonstrate limited penetration of certain anti-infective agents through silicone hydrogel contact lenses. Further studies regarding the clinical benefit of using these agents along with bandage contact lens use for corneal pathology are warranted. PMID:25806673

  5. The Influence of Instructional Minutes on Grade 11 Language Arts and Mathematics High School Proficiency Assessment Performance

    ERIC Educational Resources Information Center

    Welcome, Simone E.

    2017-01-01

    The purpose for this cross-sectional, non-experimental explanatory quantitative research study was to explain the amount of variance in the High School Proficiency Assessment-11 Language Arts and Mathematics scores accounted for by the amount of instructional minutes at high schools in New Jersey. A proportional, stratified random sample which…

  6. Endotoxin removal by radio frequency gas plasma (glow discharge)

    NASA Astrophysics Data System (ADS)

    Poon, Angela

    2011-12-01

    Contaminants remaining on implantable medical devices, even following sterilization, include dangerous fever-causing residues of the outer lipopolysaccharide-rich membranes of Gram-negative bacteria such as the common gut microorganism E. coli. The conventional method for endotoxin removal is by Food & Drug Administration (FDA)-recommended dry-heat depyrogenation at 250°C for at least 45 minutes, an excessively time-consuming high-temperature technique not suitable for low-melting or heat-distortable biomaterials. This investigation evaluated the mechanism by which E. coli endotoxin contamination can be eliminated from surfaces during ambient temperature single 3-minute to cumulative 15-minute exposures to radio-frequency glow discharge (RFGD)-generated residual room air plasmas activated at 0.1-0.2 torr in a 35MHz electrodeless chamber. The main analytical technique for retained pyrogenic bio-activity was the Kinetic Chromogenic Limulus Amebocyte Lysate (LAL) Assay, sufficiently sensitive to document compliance with FDA-required Endotoxin Unit (EU) titers less than 20 EU per medical device by optical detection of enzymatic color development corresponding to < 0.5 EU/ml in sterile water extracts of each device. The main analytical technique for identification of chemical compositions, amounts, and changes during sequential reference Endotoxin additions and subsequent RFGD-treatment removals from infrared (IR)-transparent germanium (Ge) prisms was Multiple Attenuated Internal Reflection (MAIR) infrared spectroscopy sensitive to even monolayer amounts of retained bio-contaminant. KimaxRTM 60 mm x 15 mm and 50mm x 15mm laboratory glass dishes and germanium internal reflection prisms were inoculated with E. coli bacterial endotoxin water suspensions at increments of 0.005, 0.05, 0.5, and 5 EU, and characterized by MAIR-IR spectroscopy of the dried residues on the Ge prisms and LAL Assay of sterile water extracts from both glass and Ge specimens. The Ge prism MAIR-IR measurements were repeated after employing 3-minute RFGD treatments sequentially for more than 10 cycles to observe removal of deposited matter that correlated with diminished EU titers. The results showed that 5 cycles, for a total exposure time of 15 minutes to low-temperature gas plasma, was sufficient to reduce endotoxin titers to below 0.05 EU/ml, and correlated with concurrent reduction of major endotoxin reference standard absorption bands at 3391 cm-1, 2887 cm-1, 1646 cm -1 1342 cm-1, and 1103 cm-1 to less than 0.05 Absorbance Units. Band depletion varied from 15% to 40% per 3-minute cycle of RFGD exposure, based on peak-to-peak analyses. In some cases, 100% of all applied biomass was removed within 5 sequential 3-minute RFGD cycles. The lipid ester absorption band expected at 1725 cm-1 was not detectable until after the first RFGD cycle, suggesting an unmasking of the actual bacterial endotoxin membrane induced within the gas plasma environment. Future work must determine the applicability of this low-temperature, quick depyrogenation process to medical devices of more complicated geometry than the flat surfaces tested here.

  7. Science & Technology Review October 2005

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aufderheide III, M B

    This month's issue has the following articles: (1) Important Missions, Great Science, and Innovative Technology--Commentary by Cherry A. Murray; (2) NanoFoil{reg_sign} Solders with Less Heat--Soldering and brazing to join an array of materials are now Soldering and brazing to join an array of materials are now possible without furnaces, torches, or lead; (3) Detecting Radiation on the Move--An award-winning technology can detect even small amounts An award-winning technology can detect even small amounts of radioactive material in transit; (4) Identifying Airborne Pathogens in Time to Respond--A mass spectrometer identifies airborne spores in less than A mass spectrometer identifies airborne sporesmore » in less than a minute with no false positives; (5) Picture Perfect with VisIt--The Livermore-developed software tool VisIt helps scientists The Livermore-developed software tool VisIt helps scientists visualize and analyze large data sets; (6) Revealing the Mysteries of Water--Scientists are using Livermore's Thunder supercomputer and new algorithms to understand the phases of water; and (7) Lightweight Target Generates Bright, Energetic X Rays--Livermore scientists are producing aerogel targets for use in inertial Livermore scientists are producing aerogel targets for use in inertial confinement fusion experiments and radiation-effects testing.« less

  8. The Impact of the Built Environment on Young People’s Physical Activity Patterns: A Suburban-Rural Comparison Using GPS

    PubMed Central

    Collins, Peter; Al-Nakeeb, Yahya; Nevill, Alan; Lyons, Mark

    2012-01-01

    The built environment in which young people live has a significant influence on their physical activity (PA). However, little is known regarding how youth from suburban and rural settings utilise their surrounding environments to participate in free-living PA. 50 adolescents aged 13–14 years old (22 rural; 28 suburban) wore an integrated GPS and heart rate device during non-school hours and completed a daily PA diary over 7 days. Descriptive statistics and analyses of variance were used to explore differences in the amount and location of moderate-to-vigorous physical activity (MVPA) between genders and youth from different geographical settings. Suburban youth participated in significantly (p = 0.004) more daily PA (52.14 minutes MVPA) and were more extensive in their utilisation of their surroundings, compared to rural youth (26.61 minutes MVPA). Suburban youth visited more public recreational facilities and spent significantly more time outdoors and on local streets (109.71 minutes and 44.62 minutes, respectively) compared to rural youth (55.98 minutes and 17.15 minutes, respectively) during weekdays. Rural youth on average spent significantly more time within the home (350.69 minutes) during weekends compared to suburban youth (214.82 minutes). Rural females were the least active group of adolescents, participating in the least amount of daily PA (20.14 minutes MVPA) and spending the least amount of time outdoors (31.37 minutes) during weekdays. Time spent outdoors was positively associated with PA. The findings highlight the disparity in PA levels and the utilisation of the surrounding built environment between youth from two different geographical settings and possible environmental causes are discussed. The study supports the use of GPS (combined with other methods) in investigating geographical differences in young people’s PA and movement patterns. This method provides a wealth of information that may assist future policies and interventions in identifying environmental characteristics that promote PA in youth from different geographical settings. PMID:23202669

  9. The impact of the built environment on young people's physical activity patterns: a suburban-rural comparison using GPS.

    PubMed

    Collins, Peter; Al-Nakeeb, Yahya; Nevill, Alan; Lyons, Mark

    2012-08-24

    The built environment in which young people live has a significant influence on their physical activity (PA). However, little is known regarding how youth from suburban and rural settings utilise their surrounding environments to participate in free-living PA. 50 adolescents aged 13-14 years old (22 rural; 28 suburban) wore an integrated GPS and heart rate device during non-school hours and completed a daily PA diary over 7 days. Descriptive statistics and analyses of variance were used to explore differences in the amount and location of moderate-to-vigorous physical activity (MVPA) between genders and youth from different geographical settings. Suburban youth participated in significantly (p = 0.004) more daily PA (52.14 minutes MVPA) and were more extensive in their utilisation of their surroundings, compared to rural youth (26.61 minutes MVPA). Suburban youth visited more public recreational facilities and spent significantly more time outdoors and on local streets (109.71 minutes and 44.62 minutes, respectively) compared to rural youth (55.98 minutes and 17.15 minutes, respectively) during weekdays. Rural youth on average spent significantly more time within the home (350.69 minutes) during weekends compared to suburban youth (214.82 minutes). Rural females were the least active group of adolescents, participating in the least amount of daily PA (20.14 minutes MVPA) and spending the least amount of time outdoors (31.37 minutes) during weekdays. Time spent outdoors was positively associated with PA. The findings highlight the disparity in PA levels and the utilisation of the surrounding built environment between youth from two different geographical settings and possible environmental causes are discussed. The study supports the use of GPS (combined with other methods) in investigating geographical differences in young people's PA and movement patterns. This method provides a wealth of information that may assist future policies and interventions in identifying environmental characteristics that promote PA in youth from different geographical settings.

  10. Carbon dioxide narcosis due to inappropriate oxygen delivery: a case report.

    PubMed

    Herren, Thomas; Achermann, Eva; Hegi, Thomas; Reber, Adrian; Stäubli, Max

    2017-07-28

    Oxygen delivery to patients with chronic obstructive pulmonary disease may be challenging because of their potential hypoxic ventilatory drive. However, some oxygen delivery systems such as non-rebreathing face masks with an oxygen reservoir bag require high oxygen flow for adequate oxygenation and to avoid carbon dioxide rebreathing. A 72-year-old Caucasian man with severe chronic obstructive pulmonary disease was admitted to the emergency department because of worsening dyspnea and an oxygen saturation of 81% measured by pulse oximetry. Oxygen was administered using a non-rebreathing mask with an oxygen reservoir bag attached. For fear of removing the hypoxic stimulus to respiration the oxygen flow was inappropriately limited to 4L/minute. The patient developed carbon dioxide narcosis and had to be intubated and mechanically ventilated. Non-rebreathing masks with oxygen reservoir bags must be fed with an oxygen flow exceeding the patient's minute ventilation (>6-10 L/minute.). If not, the amount of oxygen delivered will be too small to effectively increase the arterial oxygen saturation. Moreover, the risk of carbon dioxide rebreathing dramatically increases if the flow of oxygen to a non-rebreathing mask is lower than the minute ventilation, especially in patients with chronic obstructive pulmonary disease and low tidal volumes. Non-rebreathing masks (with oxygen reservoir bags) must be used cautiously by experienced medical staff and with an appropriately high oxygen flow of 10-15 L/minute. Nevertheless, arterial blood gases must be analyzed regularly for early detection of a rise in partial pressure of carbon dioxide in arterial blood in patients with chronic obstructive pulmonary disease and a hypoxic ventilatory drive. These patients are more safely managed using a nasal cannula with an oxygen flow of 1-2L/minute or a simple face mask with an oxygen flow of 5L/minute.

  11. Priming effect of platelet activating factor on leukotriene C4 from stimulated eosinophils of asthmatic patients.

    PubMed Central

    Shindo, K.; Koide, K.; Hirai, Y.; Sumitomo, M.; Fukumura, M.

    1996-01-01

    BACKGROUND: Eosinophils from asthmatic patients are known to release greater amounts of leukotrienes than normal eosinophils when stimulated by the calcium ionophore A23187. The effect of platelet activating factor (PAF) in priming eosinophils was investigated. METHODS: Eosinophils were obtained from 18 asthmatic patients and 18 healthy donors. Cells separated by the Percoll gradients were incubated with PAF (C-18) for 30 minutes and then stimulated with the calcium ionophore A23187 (2.5 microM) for 15 minutes. The amount of leukotriene C4 (LTC4) in supernatants was measured using a combination of high pressure liquid chromatography and radioimmunoassay. RESULTS: The mean (SD) amount of LTC4 released by eosinophils from asthmatic patients upon stimulation with the calcium ionophore A23187 alone was 27.9 (9.9) ng/10(6) cells (n = 6). The amount of LTC4 released following stimulation with the calcium ionophore A23187 after pretreatment with PAF (1, 5, and 10 microM) was 57.2 (8.9), 75.1 (14.3), and 52.6 (10.7) ng/10(6) cells (n = 6), respectively. Trace amounts of LTC4 (0.9 (0.02) ng/10(6) cells, n = 6) were detected in the supernatant of the cells after stimulation by PAF alone (5 microM). The amount of LTC4 released upon stimulation by calcium ionophore A23187 alone in eosinophils from healthy donors was 10.3 (3.7) ng/10(6) cells (n = 4). The amounts of LTC4 released upon stimulation with calcium ionophore A23187 after pretreatment with PAF at concentrations of 1, 5, and 10 microM were 11.9 (3.5), 17.8 (5.6), and 12.7 (5.1) ng/10(6) cells (n = 4), respectively. Trace amounts of LTC4 (0.6 (0.02) ng/10(6) cells, n = 4) were detected in the supernatant of the cells upon stimulation with PAF alone (5 microM). The amounts of LTC4 released upon stimulation with calcium ionophore A23187 after pretreatment with lyso-PAF at concentrations of 1, 5, and 10 microM (n = 4 or 6) were 30.8 (5.2), 22.9 (5.1), and 27.3 (4.3) ng/10(6) cells (n = 6) from the eosinophils of asthmatic patients and 13.7 (3.3), 15.2 (4.9), and 14.7 (3.8) ng/10(6) cells (n = 4) from the eosinophils of healthy donors. CONCLUSIONS: The results indicated that PAF enhanced LTC4 formation by eosinophils obtained from asthmatic patients stimulated with the calcium ionophore A23187, but not those obtained from normal subjects. PMID:8711647

  12. From sample-to-answer: integrated genotyping and immunological analysis microfluidic platforms for the diagnostic and treatment of coeliac disease

    NASA Astrophysics Data System (ADS)

    Jung, M.; Höth, J.; Erwes, J.; Latta, D.; Strobach, X.; Hansen-Hagge, T.; Klemm, R.; Gärtner, C.; Demiris, T. M.; O'Sullivan, C.; Ritzi-Lehnert, M.; Drese, K. S.

    2011-02-01

    Taking advantage of microfluidics technology, a Lab-on-Chip system was developed offering the possibility of performing HLA (Human Leukocyte Antigen) typing to test genetic predisposition to coeliac disease and measure the level of immunodeficiency at the point-of-care. These analysis procedures are implemented on two different microfluidic cartridges, both having identical interfacial connections to the identical automated instrument. In order to assess the concentration of the targeted analytes in human blood, finger prick samples are processed to either extract genomic DNA carrying the coeliac disease gene or blood plasma containing the disease specific antibodies. We present here the different microfluidic modules integrated in a common platform, capable of automated sample preparation and analyte detection. In summary, this new microfluidic approach will dramatically reduce the costs of materials (polymer for the disposable chips and minute amount of bio-reagents) and minimize the time for analysis down to less than 20 minutes. In comparison to the state of the art detection of coeliac disease this work represents a tremendous improvement for the patient's quality of live and will significantly reduce the cost burden on the health care system.

  13. Comparison of birds detected from roadside and off-road point counts in the Shenandoah National Park

    USGS Publications Warehouse

    Keller, C.M.E.; Fuller, M.R.; Ralph, C. John; Sauer, John R.; Droege, Sam

    1995-01-01

    Roadside point counts are generally used for large surveys to increase the number of samples. We examined differences in species detected from roadside versus off-road (200-m and 400-ha) point counts in the Shenandoah National Park. We also compared the list of species detected in the first 3 minutes to those detected in 10 minutes for potential species biases. Results from 81 paired roadside and off-road counts indicated that roadside counts had higher numbers of several edge species but did not have lower numbers of nonedge forest species. More individuals and species were detected from roadside points because of this increase in edge species. Sixty-five percent of the species detected in 10 minutes were recorded in the first 3 minutes.

  14. BREEDING EXPERIMENTS ON MEDICINAL PLANTS. 27. ROENTGEN MUTATIONS AND ACTIVE SUBSTANCE CONTENT IN DATURA (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinegger, E.; Zbinden, F.

    1961-10-01

    The changes in alkaloid content of the Datura stramonium var. godronii are considered. About 1000 plants cultivated from irradiated and nonlrradiated seeds were examined for changes in total alkaloid content. In about 1.5% of the plants the alknloid content changed considerably, the decreases being more marked than the increases. Completely alkaloid-free plants, however, were not produced, in spite of the fact that occasionally the alkaloid content was so low that it could no longer be determined. There were two groups of mutants with increased alkaloid content. Some pharmaceutically important plants with higher total alkaloid production per plant and with loweredmore » alkaloid drug yield had double chromosome numbers and proved to be autotetraploid. However, the alkaloid contents of these plants were not higher than those of the artificially cultivated polyploids. The alkaloid content was evaluated by paper chromatography, which made possible the extraction of minute amounts of water- soluble basic amines as well as preventing the secondary changes of alkaloids. New alkaloids were not detected. Scopolamine content was found to decrease with age of the plant. In some mutants a reciprocal change in the amounts of some alkaloids could be demonstrated. A mutant containing a large amount of cuskohygrine was detected. (BBB)« less

  15. An efficient and rapid transgenic pollen screening and detection method using flow cytometry.

    PubMed

    Moon, Hong S; Eda, Shigetoshi; Saxton, Arnold M; Ow, David W; Stewart, C Neal

    2011-01-01

    Assaying for transgenic pollen, a major vector of transgene flow, provides valuable information and essential data for the study of gene flow and assessing the effectiveness of transgene containment. Most studies have employed microscopic screening methods or progeny analyses to estimate the frequency of transgenic pollen. However, these methods are time-consuming and laborious when large numbers of pollen grains must be analyzed to look for rare transgenic pollen grains. Thus, there is an urgent need for the development of a simple, rapid, and high throughput analysis method for transgenic pollen analysis. In this study, our objective was to determine the accuracy of using flow cytometry technology for transgenic pollen quantification in practical application where transgenic pollen is not frequent. A suspension of non-transgenic tobacco pollen was spiked with a known amount of verified transgenic tobacco pollen synthesizing low or high amounts of green fluorescent protein (GFP). The flow cytometric method detected approximately 75% and 100% of pollen grains synthesizing low and high amounts of GFP, respectively. The method is rapid, as it is able to count 5000 pollen grains per minute-long run. Our data indicate that this flow cytometric method is useful to study gene flow and assessment of transgene containment.

  16. Multivalent Nanoparticle Networks Enable Point of Care Detection of Human Phospholipase-A2 in Serum

    PubMed Central

    Burnapp, Mark; Bentham, Andrew; Hillier, David; Zabron, Abigail; Khan, Shahid; Tyreman, Matthew; Stevens, Molly M.

    2017-01-01

    A rapid and highly sensitive point of care (PoC) lateral flow assay for phospholipase-A2 (PLA2) is demonstrated in serum through the enzyme-triggered release of a new class of biotinylated multi-armed polymers from a liposome substrate. Signal from the enzyme activity is generated by the adhesion of polystreptavidin coated gold nanoparticle networks to the lateral flow device, which leads to the appearance of a red test line due to the localised surface plasmon resonance (LSPR) effect of the gold. The use of a liposome as the enzyme substrate and multivalent linkers to link the nanoparticles leads to amplification of the signal as the cleavage of a small amount of lipids is able to release a large amount of polymer linker and adhesion of an even larger amount of gold nanoparticles. By optimising the molecular weight and multivalency of these biotinylated polymer linkers the sensitivity of the device can be tuned to enable naked-eye detection of 1 nM human-PLA2 in serum within 10 minutes. This high sensitivity enabled the correct diagnosis of pancreatitis in diseased clinical samples against a set of healthy controls using PLA2 activity in a point of care device for the first time. PMID:25756526

  17. Single-Molecule Flow Platform for the Quantification of Biomolecules Attached to Single Nanoparticles.

    PubMed

    Jung, Seung-Ryoung; Han, Rui; Sun, Wei; Jiang, Yifei; Fujimoto, Bryant S; Yu, Jiangbo; Kuo, Chun-Ting; Rong, Yu; Zhou, Xing-Hua; Chiu, Daniel T

    2018-05-15

    We describe here a flow platform for quantifying the number of biomolecules on individual fluorescent nanoparticles. The platform combines line-confocal fluorescence detection with near nanoscale channels (1-2 μm in width and height) to achieve high single-molecule detection sensitivity and throughput. The number of biomolecules present on each nanoparticle was determined by deconvolving the fluorescence intensity distribution of single-nanoparticle-biomolecule complexes with the intensity distribution of single biomolecules. We demonstrate this approach by quantifying the number of streptavidins on individual semiconducting polymer dots (Pdots); streptavidin was rendered fluorescent using biotin-Alexa647. This flow platform has high-throughput (hundreds to thousands of nanoparticles detected per second) and requires minute amounts of sample (∼5 μL at a dilute concentration of 10 pM). This measurement method is an additional tool for characterizing synthetic or biological nanoparticles.

  18. An improved UPLC method for the detection of undeclared horse meat addition by using myoglobin as molecular marker.

    PubMed

    Di Giuseppe, Antonella M A; Giarretta, Nicola; Lippert, Martina; Severino, Valeria; Di Maro, Antimo

    2015-02-15

    In 2013, following the scandal of the presence of undeclared horse meat in various processed beef products across the Europe, several researches have been undertaken for the safety of consumer health. In this framework, an improved UPLC separation method has been developed to detect the presence of horse myoglobin in raw meat samples. The separation of both horse and beef myoglobins was achieved in only seven minutes. The methodology was improved by preparing mixtures with different composition percentages of horse and beef meat. By using myoglobin as marker, low amounts (0.50mg/0.50g, w/w; ∼0.1%) of horse meat can be detected and quantified in minced raw meat samples with high reproducibility and sensitivity, thus offering a valid alternative to conventional PCR techniques. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. An improved synthesis of 2,4,8,10-tetroxaspiro /5.5/ undecane /pentaerythritol diformal/

    NASA Technical Reports Server (NTRS)

    Poshkus, A. C.

    1979-01-01

    It is found that high yields of pentaerythritol diformal can be prepared in less than 10 minutes by heating a stirred mixture of pentaerythritol with a slight excess of paraformaldehyde up to about 120 C in the presence of catalic amounts of acid, but without any solvents or with only a small amount of water. The reaction was carried out in two stages: first by preparing the monoformal with a molar equivalent of paraformaldehyde in about five minutes, and then, after cooling to about 70 C, adding the remainder of paraformaldehyde in 1% excess, and heating to about 120 C for a total heating time of 10 minutes

  20. Comparative verification between GEM model and official aviation terminal forecasts

    NASA Technical Reports Server (NTRS)

    Miller, Robert G.

    1988-01-01

    The Generalized Exponential Markov (GEM) model uses the local standard airways observation (SAO) to predict hour-by-hour the following elements: temperature, pressure, dew point depression, first and second cloud-layer height and amount, ceiling, total cloud amount, visibility, wind, and present weather conditions. GEM is superior to persistence at all projections for all elements in a large independent sample. A minute-by-minute GEM forecasting system utilizing the Automated Weather Observation System (AWOS) is under development.

  1. Boundaries and Topological Algorithms

    DTIC Science & Technology

    1988-08-01

    phrases using "for" to measure an amount of time, as illustrated by Sentences 9-11: (9) The aide shredded incriminating documents for several minutes . ( 10 ...Bonnie passed her area exam for several minutes . (11) #Eric made a fresh pot of coffee for several minutes . 10 State changes are distinguished from...data are summarized by Poggio and Poggio (1984). Mea- sured values for Panum’s area seem to be approximately ± 10 minutes of arc in both the

  2. Alternate Protocol for Detecting Biological Contamination on Sensitive Hardware

    NASA Technical Reports Server (NTRS)

    Berlin, David; Lalime, Erin; Carosso, Nancy

    2015-01-01

    The purpose of this project is to develop a sterile water based rapid bioburden test. Contamination engineers use two tests to assess the level of biological contamination on hardware: the rapid five minute bioburden test, which is a molecular screening for Adenosine triphosphate (ATP), a molecule found in all cells on the hardware, and a slower colony growth test, which is used to give a more accurate representation of the amount of microbes on the hardware. However, the rapid bioburden test has limited application because it leaves a residue that can be detrimental to sensitive hardware. This can cause project delays while waiting for the results from the three day colony growth test. We address this problem by adapting the commercial germicide based ATP system to a sterile water based system. The test works by reacting ATP with D-Luciferin and Luciferase protein to yield light. The light is then detected by a luminometer that outputs a Relative Light Unit (RLU) amount depending on how much ATP is present. To analyze the effectiveness of the new test, we developed a correlation between amounts of ATP and the RLU produced using the germicide based system. From these experiments, we've generated a consistent relationship between the two in the form of a power curve. From there, we developed a correlation curve between the amount of colonies and the RLU they produced. Initial tests of the new protocol have shown that the water based system isn't as sensitive as the germicide based test.

  3. Asteroid detection using a single multi-wavelength CCD scan

    NASA Astrophysics Data System (ADS)

    Melton, Jonathan

    2016-09-01

    Asteroid detection is a topic of great interest due to the possibility of diverting possibly dangerous asteroids or mining potentially lucrative ones. Currently, asteroid detection is generally performed by taking multiple images of the same patch of sky separated by 10-15 minutes, then subtracting the images to find movement. However, this is time consuming because of the need to revisit the same area multiple times per night. This paper describes an algorithm that can detect asteroids using a single CCD camera scan, thus cutting down on the time and cost of an asteroid survey. The algorithm is based on the fact that some telescopes scan the sky at multiple wavelengths with a small time separation between the wavelength components. As a result, an object moving with sufficient speed will appear in different places in different wavelength components of the same image. Using image processing techniques we detect the centroids of points of light in the first component and compare these positions to the centroids in the other components using a nearest neighbor algorithm. The algorithm was used on a test set of 49 images obtained from the Sloan telescope in New Mexico and found 100% of known asteroids with only 3 false positives. This algorithm has the advantage of decreasing the amount of time required to perform an asteroid scan, thus allowing more sky to be scanned in the same amount of time or freeing a telescope for other pursuits.

  4. Molecular beacon-based real-time PCR method for detection of porcine DNA in gelatin and gelatin capsules.

    PubMed

    Mohamad, Nurhidayatul Asma; Mustafa, Shuhaimi; Khairil Mokhtar, Nur Fadhilah; El Sheikha, Aly Farag

    2018-03-05

    The pharmaceutical industry has boosted gelatin consumption worldwide. This is supported by the availability of cost-effective gelatin production from porcine by-products. However, cross-contamination of gelatin materials, where porcine gelatin was unintentionally included in the other animal sources of gelatin, has caused significant concerns about halal authenticity. The real-time polymerase chain reaction (PCR) has enabled a highly specific and sensitive animal species detection method in various food products. Hence, such a technique was employed in the present study to detect and quantify porcine DNA in gelatin using a molecular beacon probe, with differences in performance between mitochondrial (cytochrome b gene) and chromosomal DNA-(MPRE42 repetitive element) based porcine-specific PCR assays being compared. A higher sensitivity was observed in chromosomal DNA (MPRE-PCR assay), where this assay allows the detection of gelatin DNA at amounts as as low as 1 pg, whereas mitochondrial DNA (CBH-PCR assay) can only detect at levels down to 10 pg of gelatin DNA. When an analysis with commercial gelatin and gelatin capsule samples was conducted, the same result was observed, with a significantly more sensitive detection being provided by the repetitive element of chromosomal DNA. The present study has established highly sensitive DNA-based porcine detection systems derived from chromosomal DNA that are feasible for highly processed products such as gelatin and gelatin capsules containing a minute amount of DNA. This sensitive detection method can also be implemented to assist the halal authentication process of various food products available on the market. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  5. Rapid, sensitive and label-free detection of Shiga-toxin producing Escherichia coli O157 using carbon nanotube biosensors.

    PubMed

    Subramanian, Sowmya; Aschenbach, Konrad H; Evangelista, Jennifer P; Najjar, Mohamed Badaoui; Song, Wenxia; Gomez, Romel D

    2012-02-15

    An electronic platform to detect very small amounts of genomic DNA from bacteria without the need for PCR amplification and molecular labeling is described. The system uses carbon nanotube field-effect transistor (FET) arrays whose electrical properties are affected by minute electrical charges localized on their active regions. Two pathogenic strains of E. coli are used to evaluate the detection properties of the transistor arrays. Described herein are the results for detection of synthetic oligomers, unpurified and highly purified genomic DNA at various concentrations and their comparison against non-specific binding. In particular, the capture of genomic DNA of E. coli O157:H7 by a specific oligonucleotide probe coated onto the transistor array results in a significant shift in the threshold (gate-source) voltage (V(th)). By contrast the signal under the same procedure using a different strain, E. coli O45 that is non-complementary to the probe remained nearly constant. This work highlights the detection sensitivity and efficacy of this biosensor without stringent requirement for DNA sample preparation. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Detection of minute virus of mice using real time quantitative PCR in assessment of virus clearance during the purification of Mammalian cell substrate derived biotherapeutics.

    PubMed

    Zhan, Dejin; Roy, Margaret R; Valera, Christine; Cardenas, Jesse; Vennari, Joann C; Chen, Janice W; Liu, Shengjiang

    2002-12-01

    A real time quantitative PCR assay has been developed for detecting minute virus of mice (MVM). This assay directly quantifies PCR product by monitoring the increase of fluorescence intensity emitted during enzymatic hydrolysis of an oligonucleotide probe labelled covalently with fluorescent reporting and quenching dyes via Taq polymerase 5'-->3' exonuclease activity. The quantity of MVM DNA molecules in the samples was determined using a known amount of MVM standard control DNA fragment cloned into a plasmid (pCR-MVM). We have demonstrated that MVM TaqMan PCR assay is approximately 1000-fold more sensitive than the microplate infectivity assay with the lowest detection limit of approximately one particle per reaction. The reliable detection range is within 100 to 10(9) molecules per reaction with high reproducibility. The intra assay variation is <2.5%, and the inter assays variation is <6.5% when samples contain >100 particles/assay. When we applied the TaqMan PCR to MVM clearance studies done by column chromatography or normal flow viral filtration, we found that the virus removal factors were similar to that of virus infectivity assay. It takes about a day to complete entire assay processes, thus, the TaqMan PCR assay is at least 10-fold faster than the infectivity assay. Therefore, we concluded that this fast, specific, sensitive, and robust assay could replace the infectivity assay for virus clearance evaluation. Copyright 2002 The International Association for Biologicals. Published by Elsevier Science Ltd. All rights reserved.

  7. Validity of PALMS GPS scoring of active and passive travel compared with SenseCam.

    PubMed

    Carlson, Jordan A; Jankowska, Marta M; Meseck, Kristin; Godbole, Suneeta; Natarajan, Loki; Raab, Fredric; Demchak, Barry; Patrick, Kevin; Kerr, Jacqueline

    2015-03-01

    The objective of this study is to assess validity of the personal activity location measurement system (PALMS) for deriving time spent walking/running, bicycling, and in vehicle, using SenseCam (Microsoft, Redmond, WA) as the comparison. Forty adult cyclists wore a Qstarz BT-Q1000XT GPS data logger (Qstarz International Co., Taipei, Taiwan) and SenseCam (camera worn around the neck capturing multiple images every minute) for a mean time of 4 d. PALMS used distance and speed between global positioning system (GPS) points to classify whether each minute was part of a trip (yes/no), and if so, the trip mode (walking/running, bicycling, or in vehicle). SenseCam images were annotated to create the same classifications (i.e., trip yes/no and mode). Contingency tables (2 × 2) and confusion matrices were calculated at the minute level for PALMS versus SenseCam classifications. Mixed-effects linear regression models estimated agreement (mean differences and intraclass correlation coefficients) between PALMS and SenseCam with regard to minutes/day in each mode. Minute-level sensitivity, specificity, and negative predictive value were ≥88%, and positive predictive value was ≥75% for non-mode-specific trip detection. Seventy-two percent to 80% of outdoor walking/running minutes, 73% of bicycling minutes, and 74%-76% of in-vehicle minutes were correctly classified by PALMS. For minutes per day, PALMS had a mean bias (i.e., amount of over or under estimation) of 2.4-3.1 min (11%-15%) for walking/running, 2.3-2.9 min (7%-9%) for bicycling, and 4.3-5 min (15%-17%) for vehicle time. Intraclass correlation coefficients were ≥0.80 for all modes. PALMS has validity for processing GPS data to objectively measure time spent walking/running, bicycling, and in vehicle in population studies. Assessing travel patterns is one of many valuable applications of GPS in physical activity research that can improve our understanding of the determinants and health outcomes of active transportation as well as its effect on physical activity.

  8. Capillary electrophoresis: Biotechnology for separation of DNA and chromosomes

    NASA Technical Reports Server (NTRS)

    Williams, George O., Jr.

    1994-01-01

    Electrophoresis has been used for the separation of particles, ions, and molecules for a number of years. The technology for separation and detection of the results has many applications in the life sciences. One of the major goals of the scientific community is to separate DNA molecules and intact chromosomes based upon their different lengths or number of base pairs. This may be achieved by using some of the commercially available and widely used methods, but these processes require a considerable amount of time. The challenge is to achieve separation of intact chromosomes in a short time, preferably in a matter of minutes.

  9. [Neuron differential attachment purification and its influence factor].

    PubMed

    Li, Jun; Feng, Daxiong; Huang, Yize; Ye, Fei

    2010-02-01

    Neuron purification is essential to procedure of various nerve cell experimental research, however, at present there is few reports on the effect of various factors on neural axons during purification. To find out a simple method of neuron purification, and to investigate the influence factors of corresponding purification culture in dorsal root ganglion (DRG) tissue culture on beta3-tubulin positive axon. The DRGs were obtained from the 3 days neonatal SD rat microscopically and were made into cell suspension. Then, the amount of attached DRG neurons and nonneuronal cells in poly-D-lysine (PDL) group, PDL/Laminin (PDL/LN) group and collagen-I (Col I) group was observed from 10 to 100 minutes. Then, the extension and arborization of beta3-tubulin positive axons were observed after 72 hours completely randomised DRG tissue culture for the research of the influences among culture substrates (PDL, PDL/LN, and Col I), FBS (0, 5%, and 10%), 5 fluorouracil (5-Fu, 0, 20, and 40 micromol/L), and cytarabine (Ara-C, 0, 10, and 20 micromol/L). Adherent cells were observed instantly after inoculation by inverted phase contrast microscope and inverted fluorescence microscope; after cell suspension was removed, adherent growth of DRGn cells and non-DRGn cells were still seen. In PDL group, the amount of NSE negative cells was significantly higher than that of NSE positive cells at 10 and 30 minutes (P < 0.05); the amount of NSE positive cells was significantly higher than that of NSE negative cells at 80, 90 and 100 minutes (P < 0.05). In PDL/LN group, there was no significant difference (P > 0.05) in the amount of NSE negative cells and NSE positive cells at 10, 20, 30, 40, and 50 minutes; the amount of NSE positive cells was significantly higher (P < 0.05) than that of NSE negative cells at 60, 70, 80, 90, 100 minutes. In Col I group, the amount of NSE negative cells was higher than that of NSE positive cells at 10-40 minutes, but showing no significant difference (P > 0.05); the amount of NSE positive cells was significantly higher (P < 0.05) than that of NSE negative cells at 70-100 minutes. At 72 hours after DRG tissue culture, the best result of beta3-tubulin positive axon extension and arborization was obtained when the substrate level was PDL/LN, and the average length of PDL/LN level was significantly larger than that of other two substrates (P < 0.05). The highest number of beta3-tubulin positive axon distal end was obtained at 5% concentration level of FBS (P < 0.05), but showing no significant differences in beta3-tubulin positive axon length among three levels (P > 0.05). Both the most of beta3-tubulin positive axon distal ends and the longest beta3-tubulin positive axon average length were obtained at 0 micromol/L concentration level of 5-Fu, showing significant differences between 0 micromol/L level and 20, 40 micromol/L levels (P < 0.05). A similar result of 33-tubulin positive axon distal end was got at the 0 micromol/L level and 10 micromol/L level of Ara-C, which was significantly higher than that of 20 micromol/L level (P < 0.05). A purified DRG neuron suspension for neuron culture could be obtained via PDL differential attachment for 30 minutes. When DRG neuron culture, neuron special medium, PDL/LN substrate and 10 micromol/L Ara-C are recommended in beta3-tubulin positive axon research.

  10. Simulated low-intensity optical pulsar observation with single-photon detector

    NASA Astrophysics Data System (ADS)

    Leeb, W. R.; Alves, J.; Meingast, S.; Brunner, M.

    2015-02-01

    Context. Optical radiation of pulsars offers valuable clues to the physics of neutron stars, which are our only probes of the most extreme states of matter in the present-day universe. Still, only about 1% of all cataloged pulsars have known optical counterparts. Aims: The goal of this work is to develop an observational method optimized for discovering faint optical pulsars. Methods: A single-photon detector transforms the signal received by the telescope into a pulse sequence. The events obtained are time tagged and transformed into a histogram of event time differences. The histogram envelope presents the autocorrelation of the recorded optical signal and thus displays any periodicity of the input signal. Results: Simulations show that faint pulsars radiating in the optical regime can be detected in a straightforward way. As an example, a fictitious pulsar with a V-magnitude of 24.6 mag and a signature like the Crab pulsar can be discovered within one minute using an 8-m class telescope. At the detector's peak sensitivity the average optical flux density would then amount to Fν = 0.63 μJy. With a 40-m class telescope, such as the forthcoming European ELT, the detection of optical pulsars with magnitudes V< 30 mag is within reach for a measurement time of one minute. A two-hour "blind search" with the ELT could reach V ~ 31.3 mag. Conclusions: This method allows detecting faint periodic optical radiation with simple equipment and easy signal processing.

  11. Stand-off imaging Raman spectroscopy for forensic analysis of post-blast scenes: trace detection of ammonium nitrate and 2,4,6-trinitrotoluene

    NASA Astrophysics Data System (ADS)

    Ceco, Ema; Önnerud, Hans; Menning, Dennis; Gilljam, John L.; Bââth, Petra; Östmark, Henric

    2014-05-01

    The following paper presents a realistic forensic capability test of an imaging Raman spectroscopy based demonstrator system, developed at FOI, the Swedish Defence Research Agency. The system uses a 532 nm laser to irradiate a surface of 25×25mm. The backscattered radiation from the surface is collected by an 8" telescope with subsequent optical system, and is finally imaged onto an ICCD camera. We present here an explosives trace analysis study of samples collected from a realistic scenario after a detonation. A left-behind 5 kg IED, based on ammonium nitrate with a TNT (2,4,6-trinitrotoluene) booster, was detonated in a plastic garbage bin. Aluminum sample plates were mounted vertically on a holder approximately 6 m from the point of detonation. Minutes after the detonation, the samples were analyzed with stand-off imaging Raman spectroscopy from a distance of 10 m. Trace amounts could be detected from the secondary explosive (ammonium nitrate with an analysis time of 1 min. Measurement results also indicated detection of residues from the booster (TNT). The sample plates were subsequently swabbed and analyzed with HPLC and GC-MS analyses to confirm the results from the stand-off imaging Raman system. The presented findings indicate that it is possible to determine the type of explosive used in an IED from a distance, within minutes after the attack, and without tampering with physical evidence at the crime scene.

  12. [Principle of LAMP method--a simple and rapid gene amplification method].

    PubMed

    Ushikubo, Hiroshi

    2004-06-01

    So far nucleic acid test (NAT) has been employed in various fields, including infectious disease diagnoses. However, due to its complicated procedures and relatively high cost, it has not been widely utilized in many actual diagnostic applications. We have therefore developed a simple and rapid gene amplification technology, Loop-mediated Isothermal Amplification (LAMP) method, which has shown prominent results of surpassing the performance of the conventional gene amplification methods. LAMP method acquires three main features: (1) all reaction can be carried out under isothermal conditions; (2) the amplification efficiency is extremely high and tremendous amount of amplification products can be obtained; and (3) the reaction is highly specific. Furthermore, developed from the standard LAMP method, a rapid LAMP method, by adding in the loop primers, can reduce the amplification time from the previous 1 hour to less than 30 minutes. Enormous amount of white precipitate of magnesium pyrophosphate is produced as a by-product of the amplification, therefore, direct visual detection is possible without using any reaction indicators and detection equipments. We believe LAMP technology, with the integration of these features, can rightly apply to clinical genetic testing, food and environmental analysis, as well as NAT in different fields.

  13. Pharmacokinetics of tramadol and its major metabolites following rectal and intravenous administration in dogs.

    PubMed

    Giorgi, M; Del Carlo, S; Saccomanni, G; Łebkowska-Wieruszewska, B; Kowalski, C J

    2009-06-01

    To compare the rectal and I/V administration of tramadol in dogs, to assess both its pharmacokinetic properties and absolute bioavailability. After rectal administration via suppositories and I/V injection of tramadol (4 mg/kg), the concentration of tramadol and its main metabolites, O-desmethyl-tramadol (M1), N-desmethyl-tramadol (M2) and N,O-didesmethyl-tramadol (M5), were determined in plasma, using high-performance liquid chromatography (HPLC). A balanced cross-over study was used, involving six male Beagle dogs. Plasma concentrations after rectal and I/V administration were fitted on the basis of mono- and bi-compartmental models, respectively. Following rectal administration tramadol was detected from 5 minutes up to 10 hours, in lesser amounts than M5 and M2, while M1 was detected in negligible amounts. Following I/V administration tramadol was detected up to 10 hours, M2 and M5 were detected at similar concentrations, and M1 was present at low concentrations. The area under the curve (AUC) of the three metabolites did not differ significantly after either route of administration of tramadol. The absolute bioavailability of tramadol via rectal administration was 10 (SD 4)%. After rectal administration of tramadol suppositories, absorption of the active ingredient was rapid, but its metabolism quickly transformed the parent drug to high levels of M2 and M5. In the dog, rectal pharmaceutical formulation of tramadol would have a different pharmacokinetic behaviour than in humans.

  14. Observations of Total Lightning Associated with Severe Convection During the Wet Season in Central Florida

    NASA Technical Reports Server (NTRS)

    Sharp, D.; Williams, E.; Weber, M.; Goodman, Steven J.; Raghavan, R.; Matlin, A.; Boldi, B.

    1998-01-01

    This paper will discuss findings of a collaborative lightning research project between National Aeronautics and Space Administration, the Massachusetts Institute of Technology and the National Weather Service office In Melbourne Florida. In August 1996, NWS/MLB received a workstation which incorporates data from the KMLB WSR-88D, Cloud to Ground (CG) stroke data from the National Lightning Detection Network (NLDN), and 3D volumetric lightning data collected from the Kennedy Space Centers' Lightning Detection And Ranging (LDAR) lightning system. The two primary objectives of this lightning workstation, called Lightning Imaging Sensor Data Applications Display (USDAD), are to: observe how total lightning relates to severe convective storm morphology over central Florida, and compare ground based total lightning data (LDAR) to a satellite based lightning detection system. This presentation will focus on objective #1. The LISDAD system continuously displays CG and total lighting activity overlaid on top of the KMLB composite reflectivity product. This allows forecasters to monitor total lightning activity associated with convective cells occurring over the central Florida peninsula and adjacent coastal waters. The LISDAD system also keeps track of the amount of total lightning data, and associated KMLB radar products with individual convective cells occurring over the region. By clicking on an individual cell, a history table displays flash rate information (CG and total lightning) in one minute increments, along with radar parameter trends (echo tops, maximum dBz and height of maximum dBz) every 5 minutes. This history table Is updated continuously, without user intervention, as long as the cell is identified. Reviewing data collected during the 1997 wet season (21 cases) revealed that storms which produced severe weather (hall greater or = 0.75 in. or wind damage) typically showed a rapid rise In total lightning prior to the onset of severe weather. On average, flash rate increases of 25 FPM per minute over a time scale of approximately 5 minutes were common. These pulse severe storms typically reached values of 150 to 200 FPM with some cells exceeding 400 FPM. One finding which could have a direct application to the warning process is that the rapid increase in lightning typically occurred in advance of the warning issuance time. Comparisons between the ending time of the rapid rate increase and the time of when the warning was issued by NWS/MLB meteorologist exhibited a lead time of 8 minutes. It is conceivable that if close monitoring of the LISDAD system by operational meteorologist is routinely performed, warnings for pulse severe storms could be issued up to 4 to 6 minutes earlier than what is issued currently.

  15. Longer mean colonoscopy withdrawal time is associated with increased adenoma detection: evidence from the Bowel Cancer Screening Programme in England.

    PubMed

    Lee, T J W; Blanks, R G; Rees, C J; Wright, K C; Nickerson, C; Moss, S M; Chilton, A; Goddard, A F; Patnick, J; McNally, R J Q; Rutter, M D

    2013-01-01

    Increasing colonoscopy withdrawal time (CWT) is thought to be associated with increasing adenoma detection rate (ADR). Current English guidelines recommend a minimum CWT of 6 minutes. It is known that in the Bowel Cancer Screening Programme (BCSP) in England there is wide variation in CWT. The aim of this observational study was to examine the relationship between CWT and ADR. The study examined data from 31 088 colonoscopies by 147 screening program colonoscopists. Colonoscopists were grouped in four levels of mean CWT ( < 7, 7 - 8.9, 9 - 10.9, and ≥ 11 minutes). Univariable and multivariable analysis (binary logistic and negative binomial regression) were used to explore the relationship between CWT, ADR, mean number of adenomas and number of right-sided and advanced adenomas. In colonoscopists with a mean CWT < 7 minutes, the mean ADR was 42.5 % compared with 47.1 % in the ≥ 11-minute group (P < 0.001). The mean number of adenomas detected per procedure increased from 0.77 to 0.94, respectively (P < 0.001). The increase in adenoma detection was mainly of subcentimeter or proximal adenomas; there was no increase in the detection of advanced adenomas. Regression models showed an increase in ADR from 43 % to 46.5 % for mean CWT times ranging from 6 to 10 minutes. This study demonstrates that longer mean withdrawal times are associated with increasing adenoma detection, mainly of small or right-sided adenomas. However, beyond 10 minutes the increase in ADR is minimal. Mean withdrawal times longer than 6 minutes are not associated with increased detection of advanced adenomas. Withdrawal time remains an important quality metric of colonoscopy. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Physical education and academic achievement in elementary school: data from the early childhood longitudinal study.

    PubMed

    Carlson, Susan A; Fulton, Janet E; Lee, Sarah M; Maynard, L Michele; Brown, David R; Kohl, Harold W; Dietz, William H

    2008-04-01

    We examined the association between time spent in physical education and academic achievement in a longitudinal study of students in kindergarten through fifth grade. We used data from the Early Childhood Longitudinal Study, Kindergarten Class of 1998 to 1999, which employed a multistage probability design to select a nationally representative sample of students in kindergarten (analytic sample = 5316). Time spent in physical education (minutes per week) was collected from classroom teachers, and academic achievement (mathematics and reading) was scored on an item response theory scale. A small but significant benefit for academic achievement in mathematics and reading was observed for girls enrolled in higher amounts (70-300 minutes per week) of physical education (referent: 0-35 minutes per week). Higher amounts of physical education were not positively or negatively associated with academic achievement among boys. Among girls, higher amounts of physical education may be associated with an academic benefit. Physical education did not appear to negatively affect academic achievement in elementary school students. Concerns about adverse effects on achievement may not be legitimate reasons to limit physical education programs.

  17. Electric Charge Accumulation in Polar and Non-Polar Polymers under Electron Beam Irradiation

    NASA Astrophysics Data System (ADS)

    Nagasawa, Kenichiro; Honjoh, Masato; Takada, Tatsuo; Miyake, Hiroaki; Tanaka, Yasuhiro

    The electric charge accumulation under an electron beam irradiation (40 keV and 60 keV) was measured by using the pressure wave propagation (PWP) method in the dielectric insulation materials, such as polar polymeric films (polycarbonate (PC), polyethylene-naphthalate (PEN), polyimide (PI), and polyethylene-terephthalate (PET)) and non-polar polymeric films (polystyrene (PS), polypropylene (PP), polyethylene (PE) and polytetrafluoroethylene (PTFE)). The PE and PTFE (non-polar polymers) showed the properties of large amount of electric charge accumulation over 50 C/m3 and long saturation time over 80 minutes. The PP and PS (non-polar polymer) showed the properties of middle amount of charge accumulation about 20 C/m3 and middle saturation time about 1 to 20 minutes. The PC, PEN, PI and PET (polar polymers) showed the properties of small amount of charge accumulation about 5 to 20 C/m3 and within short saturation time about 1.0 minutes. This paper summarizes the relationship between the properties of charge accumulation and chemical structural formula, and compares between the electro static potential distribution with negative charged polymer and its chemical structural formula.

  18. Exercise-Based School Obesity Prevention Programs: An Overview

    ERIC Educational Resources Information Center

    Yetter, Georgette

    2009-01-01

    Overweight and obesity are major health concerns for young people. Schools are particularly promising environments for preventing and treating obesity. The Institutes of Medicine recommends 60 minutes per day of physical activity for children and youth, including at least 30 minutes at school. Yet the amount of moderate to vigorous physical…

  19. Hyperforin accumulates in the translucent glands of Hypericum perforatum.

    PubMed

    Soelberg, Jens; Jørgensen, Lise Bolt; Jäger, Anna K

    2007-06-01

    Hypericum perforatum contains the therapeutically important compounds hypericin and hyperforin. Hypericin is known to accumulate in the dark glands. This investigation aimed to determine the accumulation site of hyperforin. Dark and translucent glands as well as non-secretory tissue in leaves were manually isolated under the microscope. Hyperforin content was quantified by UV HPLC. Secretory structures were surveyed anatomically. The hyperforin content of intact leaves was found to be about 3 mg g(-1) fresh tissue, whereas a content of about 7 mg g(-1) fresh material was found in isolated translucent glands. Hyperforin was found only to occur in minute amounts in dark glands (approx. 0.4 mg g(-1) fresh tissue). In non-secretory tissue no hyperforin was detected. The accumulation of hyperforin detected in the translucent glands supports the proposed hypothesis that hyperforin is synthesized by the same biosynthetic machinery as monoterpenes in the chloroplasts of cells delimiting the gland.

  20. Feasibility study on cross-linked biopolymeric concrete encapsulating selenium glass wastes.

    PubMed

    Kim, Daeik; Park, Joon-Seok; Yen, Teh Fu

    2012-08-01

    Feasibility study was conducted to encapsulate the selenium (Se) contained in glass waste, using the biopolymer-modified concrete. Biopolymer has unique characteristics to provide the chemical sites to metals or toxic compounds through the three-dimensional cross-linked structure. Very minute amount of biopolymer enhanced the characteristics of cementitious material. The resulting biopolymeric composite with selenium glass waste showed 20% higher compressive strength than ordinary concrete and the lower leaching concentration than the equipment detection limit. For a qualitative measurement, X-ray diffraction (XRD; X-ray powder diffractogram) was used to characterize the biopolymeric concrete. The optimum waste content percentage with appropriate biopolymer concrete mixture ratio was identified for its possible commercial use.

  1. Comparison of Birds Detected from Roadside and Off-Road Point Counts in the Shenandoah National Park

    Treesearch

    Cherry M.E. Keller; Mark R. Fuller

    1995-01-01

    Roadside point counts are generally used for large surveys to increase the number of samples. We examined differences in species detected from roadside versus off-road (200-m and 400-m) point counts in the Shenandoah National Park. We also compared the list of species detected in the first 3 minutes to those detected in 10 minutes for potential species biases. Results...

  2. Rapid Light-Triggered Drug Release in Liposomes Containing Small Amounts of Unsaturated and Porphyrin-Phospholipids.

    PubMed

    Luo, Dandan; Li, Nasi; Carter, Kevin A; Lin, Cuiyan; Geng, Jumin; Shao, Shuai; Huang, Wei-Chiao; Qin, Yueling; Atilla-Gokcumen, G Ekin; Lovell, Jonathan F

    2016-06-01

    Prompt membrane permeabilization is a requisite for liposomes designed for local stimuli-induced intravascular release of therapeutic payloads. Incorporation of a small amount (i.e., 5 molar percent) of an unsaturated phospholipid, such as dioleoylphosphatidylcholine (DOPC), accelerates near infrared (NIR) light-triggered doxorubicin release in porphyrin-phospholipid (PoP) liposomes by an order of magnitude. In physiological conditions in vitro, the loaded drug can be released in a minute under NIR irradiation, while liposomes maintain serum stability otherwise. This enables rapid laser-induced drug release using remarkably low amounts of PoP (i.e., 0.3 molar percent). Light-triggered drug release occurs concomitantly with DOPC and cholesterol oxidation, as detected by mass spectrometry. In the presence of an oxygen scavenger or an antioxidant, light-triggered drug release is inhibited, suggesting that the mechanism is related to singlet oxygen mediated oxidization of unsaturated lipids. Despite the irreversible modification of lipid composition, DOPC-containing PoP liposome permeabilization is transient. Human pancreatic xenograft growth in mice is significantly delayed with a single chemophototherapy treatment following intravenous administration of 6 mg kg(-1) doxorubicin, loaded in liposomes containing small amounts of DOPC and PoP. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Influence of Survey Length and Radius Size on Grassland Bird Surveys by Point Counts at Williams Lake, British Columbia

    Treesearch

    Jean-Pierre L. Savard; Tracey D. Hooper

    1995-01-01

    We examine the effect of survey length and radius on the results of point count surveys for grassland birds at Williams Lake, British Columbia. Four- and 8-minute counts detected on average 68 percent and 85 percent of the number of birds detected during 12-minute counts. The most efficient sampling duration was 4 minutes, as long as travel time between points was...

  4. Habituation and Sensitization to Filmed Violence.

    ERIC Educational Resources Information Center

    Gange, J. J.; And Others

    In an extension of an earlier study by Cline, Croft, and Courrier (1973) the effects of amount of television viewing and preference for televised violence upon autonomic responses to violent and nonviolent videotaped movie sequences were examined. Thirty-six male undergraduates watched a six-minute portion of a boxing film and a six-minute portion…

  5. Development of a Post-CMOS Compatible Nanoporous Thin Film layer Based on Al2O3

    NASA Astrophysics Data System (ADS)

    Dogan, Ö.; Buschhausen, A.; Walk, C.; Mokwa, W.; Vogt, H.

    2018-05-01

    Porous alumina is a popular material with numerous application fields. A post-CMOS compatible process chain for the fabrication of nanoporous surface based on Al2O3 by atomic layer deposition (ALD) is presented. By alternately applying small numbers of ALD cycles for Al2O3 and ZnO, a homogenous composite was accomplished, for which the principle of island growth of ALD materials at few deposition cycle numbers was utilised. By selective texture-etching of ZnO content via hydrofluoric acid (HF) in vaporous phase at 40 °C and 10.67 mbar, a porous surface of the etch resistant Al2O3 could be achieved. TOF-SIMS investigations verified the composition of ALD composite, whereas AFM and high resolution SEM images characterised the topographies of pre- and post-etched samples. Pores with opening diameters of up to 15 nm could be detected on the surface after vaporous HF treatment for 2 minutes. The amount of pores increased after an etching time of 5 minutes.

  6. Chemically Accelerated Vibratory Surface Finishing (CAVSF)

    DTIC Science & Technology

    2009-02-01

    media) • End-roughness and micro structure of different C- steels • Material removal and roughness changes versus the amount of treatment solution in...surface finishing (CAVSF) Visual appearance of strip steel test pieces during the CAVSF process. 0-120 minutes = acid treatment 120-135 minutes = water... steel during the super-finishing process 0 50 100 150 200 250 300 350 0 50 100 150 200 250 Time minutes R e m o v e d m a t e r i a l m i c r

  7. The Amount of Time to Eat Lunch is Associated with Children’s Selection and Consumption of School Meal Entrée, Fruits, Vegetable, and Milk

    PubMed Central

    Cohen, Juliana F.W.; Jahn, Jaquelyn L.; Richardson, Scott; Cluggish, Sarah A.; Parker, Ellen; Rimm, Eric B.

    2015-01-01

    Background There are currently no national standards for school lunch period lengths and little is known about the association between the amount of time students have to eat and school food selection and consumption. Objectives To examine plate waste measurements from students in the control arm from the MEALS study (2011-2012 school year) for the association of the amount of time to eat with school meal selection and consumption. Design Prospective study using up to six repeated measures among students over the school year. Participants/Setting 1001 students in grades 3-8 attending 6 participating elementary/middle schools in an urban, low-income school district where lunch period lengths varied from 20-30 minutes. Main Outcome Measures School food selection and consumption were collected using plate waste methodology. Statistical Analyses Performed Logistic regression and mixed-model ANOVA was used to examine food selection and consumption. Results Compared with meal component selection when students had at least 25 minutes to eat, students were significantly less likely to select a fruit (44% vs. 57%; p=0.0001) compared with when students had fewer than 20 minutes to eat. There were no significant differences in entrée, milk, or vegetable selection. Among those who selected a meal component, students with fewer than 20 minutes to eat consumed 13% less of their entrée (p<0.0001), 10% less of their milk (p<0.0001), and 12% less of their vegetable (p=0.0002) compared to when students had at least 25 minutes to eat. Conclusions Over the school year, a substantial number of students had insufficient time to eat, which was associated with significantly decreased entrée, milk, and vegetable consumption compared with students who had more time to eat. School policies that encourage lunches with at least 25 minutes of seated time may reduce food waste and improve dietary intake. PMID:26372337

  8. Detailed study of polystyrene solubility using pyrolysis-gas chromatography-mass spectrometry and combination with size-exclusion chromatography.

    PubMed

    Chojnacka, Aleksandra; Janssen, Hans-Gerd; Schoenmakers, Peter

    2014-01-01

    Measuring polymer solubility accurately and precisely is challenging. This is especially true at unfavourable solvent compositions, when only very small amounts of polymer dissolve. In this paper, pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) is demonstrated to be much more informative and sensitive than conventional methods, such as ultraviolet spectroscopy. By using a programmed-temperature-vapourisation injector as the pyrolysis chamber, we demonstrate that Py-GC-MS can cover up to five orders of magnitude in dissolved polymer concentrations. For polystyrene, a detection limit of 1 ng mL(-1) is attained. Dissolution in poor solvents is demonstrated to be discriminating in terms of the analyte molecular weight. Py-GC-MS additionally can yield information on polymer composition (e.g. in case of copolymers). In combination with size-exclusion chromatography, Py-GC-MS allows us to estimate the molecular weight distributions of minute amounts of a dissolved polymer and variations therein as a function of time.

  9. [A study of the sialogogic effect of cevimeline gargle].

    PubMed

    Yoshikawa, Chizuko; Takamatsu, Yasushi; Ogata, Kentaro; Hara, Shuuji; Tamura, Kazuo

    2013-02-01

    The purpose of this study was to clarify the sialogogic effect iveness of cevimeline gargle. Sequential comparison tests were conducted on healthy adult males and females who received both cevimeline and a placebo. The effect was evaluated by measuring the amount of saliva using the Saxon test and Mucus, and by recording the subjects' own perceptions of oral mucosal moisture reported according to 4 levels. First, ten subjects' measurements were taken before gargling, as well as 5 minutes, 90 minutes and 3 hours after gargling. For the cevimeline treatment, the amount of saliva reached the maximum level within 5 minutes after gargling, and a significant salivary secreting effect(p<0. 05-p<0. 001)was observed up to 90 minutes after gargling. The degree of oral moisture also reached the maximum level within 5 minutes after gargling with cevimeline, and a significant moisture effect(p<0. 05-p<0. 001)persisted up to 3 hours after gargling. After safety profiles were determined to be acceptable, an additional 19 subjects entered the study and the same results were observed. The present data, indicating that cevimeline gargle increases the saliva in healthy individuals for at least 3 hours, will be useful in clinical trials of cevimeline gargle for patients with salivary secretion disorder.

  10. Biodistribution of the GATA-3-specific DNAzyme hgd40 after inhalative exposure in mice, rats and dogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turowska, Agnieszka; Librizzi, Damiano; Baumgartl, Nadja

    The DNAzyme hgd40 was shown to effectively reduce expression of the transcription factor GATA-3 RNA which plays an important role in the regulation of Th2-mediated immune mechanisms such as in allergic bronchial asthma. However, uptake, biodistribution and pharmacokinetics of hgd40 have not been investigated yet. We examined local and systemic distribution of hgd40 in naive mice and mice suffering from experimental asthma. Furthermore, we evaluated the pharmacokinetics as a function of dose following single and repeated administration in rats and dogs. Using intranasal administration of fluorescently labeled hgd40 we demonstrated that the DNAzyme was evenly distributed in inflamed asthmatic mousemore » lungs within minutes after single dose application. Systemic distribution was investigated in mice using radioactive labeled hgd40. After intratracheal application, highest amounts of hgd40 were detected in the lungs. High amounts were also detected in the bladder indicating urinary excretion as a major elimination pathway. In serum, low systemic hgd40 levels were detected already at 5 min post application (p.a.), subsequently decreasing over time to non-detectable levels at 2 h p.a. As revealed by Single Photon Emission Computed Tomography, trace amounts of hgd40 were detectable in lungs up to 7 days p.a. Also in the toxicologically relevant rats and dogs, hgd40 was detectable in blood only shortly after inhalative application. The plasma pharmacokinetic profile was dose and time dependent. Repeated administration did not lead to drug accumulation in plasma of dogs and rats. These pharmacokinetic of hgd40 provide guidance for clinical development, and support an infrequent and convenient dose administration regimen. - Highlights: • Local and systemic distribution of GATA-3-specific DNAzyme hgd40 was investigated. • Pharmacokinetics of hgd40 was tested in rats and dogs. • hgd40 dissolved in PBS was easily taken up into the lungs after local application. • No accumulation of hgd40 was observed after multiple treatments. • Pharmacokinetic properties of hgd40 support convenient dose administration regimen.« less

  11. Does systemic lidocaine reduce ketamine requirements for endotracheal intubation in calves?

    PubMed

    Lauper, Josiane; Marolf, Vincent; Levionnois, Olivier; Schelling, Esther; Meylan, Mireille; Spadavecchia, Claudia

    2017-03-01

    To investigate whether an intravenous (IV) lidocaine bolus in calves premedicated with xylazine-butorphanol reduces the amount of ketamine required to allow endotracheal intubation. Randomized, prospective clinical study. In total, 41 calves scheduled for elective umbilical surgery. Calves were randomly assigned to one of two groups (L: lidocaine or S: saline). The calves were administered xylazine (0.07 mg kg -1 ) and butorphanol (0.1 mg kg -1 ) intramuscularly and 10 minutes later lidocaine (2 mg kg -1 ; group L) or saline (group S) IV over 1 minute. After 2 minutes, ketamine (2.5 mg kg -1 ) was injected IV. If the depth of anaesthesia was insufficient for intubation, additional ketamine (1 mg kg -1 ) was administered every minute until intubation was successful. The amount of ketamine required for intubation, respiratory rate, pulse rate, arterial pressures, the depth of sedation and conditions of endotracheal intubation after induction of anaesthesia were compared between the two groups. The calves in group L were sedated more deeply than those in group S; however, neither the median (range) amount of ketamine required for intubation, 3.5 (2.5-4.5) mg kg -1 and 3.5 (2.5-3.5) mg kg -1 , respectively, nor the induction quality differed significantly between the groups. A bolus of lidocaine (2 mg kg -1 ) administered 10 minutes after xylazine-butorphanol in calves deepened the degree of sedation but did not decrease the requirement of ketamine for endotracheal intubation. No adverse effects were recorded in the physiological variables measured. Copyright © 2017. Published by Elsevier Ltd.

  12. Effects of Point Count Duration, Time-of-Day, and Aural Stimuli on Detectability of Migratory and Resident Bird Species in Quintana Roo, Mexico

    Treesearch

    James F. Lynch

    1995-01-01

    Effects of count duration, time-of-day, and aural stimuli were studied in a series of unlimited-radius point counts conducted during winter in Quintana Roo, Mexico. The rate at which new species were detected was approximately three times higher during the first 5 minutes of each 15- minute count than in the final 5 minutes. The number of individuals and species...

  13. Routine vs extended outpatient EEG for the detection of interictal epileptiform discharges

    PubMed Central

    Britton, Jeffrey W.; Rajasekaran, Vijayalakshmi; Fabris, Rachel R.; Cherian, Perumpillichira J.; Kelly-Williams, Kristen M.; So, Elson L.; Nickels, Katherine C.; Wong-Kisiel, Lily C.; Lagerlund, Terrence D.; Cascino, Gregory D.; Worrell, Gregory A.; Wirrell, Elaine C.

    2016-01-01

    Objective: To compare the yield of epileptiform abnormalities on 30-minute recordings with those greater than 45 minutes. Methods: We performed a prospective observational cross-sectional study of all outpatient routine EEGs comparing the rate of interictal epileptiform discharges (IEDs) and clinical events during the initial 30 minutes (routine) with those occurring in the remaining 30–60 minutes (extended). A relative increase of 10% was considered clinically significant. Results: EEGs from 1,803 patients were included; overall EEG duration was 59.4 minutes (SD ±6.5). Of 426 patients with IEDs at any time during the EEG, 81 (19.1%, 95% confidence interval 15.6–23) occurred only after the initial 30 minutes. The rate of late IEDs was not associated with age, indication, IED type, or sleep deprivation. Longer recording times also increased event capture rate by approximately 30%. Conclusions: The yield of IED and event detection is increased in extended outpatient EEGs compared to 30-minute studies. PMID:26984946

  14. Routine vs extended outpatient EEG for the detection of interictal epileptiform discharges.

    PubMed

    Burkholder, David B; Britton, Jeffrey W; Rajasekaran, Vijayalakshmi; Fabris, Rachel R; Cherian, Perumpillichira J; Kelly-Williams, Kristen M; So, Elson L; Nickels, Katherine C; Wong-Kisiel, Lily C; Lagerlund, Terrence D; Cascino, Gregory D; Worrell, Gregory A; Wirrell, Elaine C

    2016-04-19

    To compare the yield of epileptiform abnormalities on 30-minute recordings with those greater than 45 minutes. We performed a prospective observational cross-sectional study of all outpatient routine EEGs comparing the rate of interictal epileptiform discharges (IEDs) and clinical events during the initial 30 minutes (routine) with those occurring in the remaining 30-60 minutes (extended). A relative increase of 10% was considered clinically significant. EEGs from 1,803 patients were included; overall EEG duration was 59.4 minutes (SD ±6.5). Of 426 patients with IEDs at any time during the EEG, 81 (19.1%, 95% confidence interval 15.6-23) occurred only after the initial 30 minutes. The rate of late IEDs was not associated with age, indication, IED type, or sleep deprivation. Longer recording times also increased event capture rate by approximately 30%. The yield of IED and event detection is increased in extended outpatient EEGs compared to 30-minute studies. © 2016 American Academy of Neurology.

  15. Gold nanoparticle-enabled blood test for early stage cancer detection and risk assessment.

    PubMed

    Zheng, Tianyu; Pierre-Pierre, Nickisha; Yan, Xin; Huo, Qun; Almodovar, Alvin J O; Valerio, Felipe; Rivera-Ramirez, Inoel; Griffith, Elizabeth; Decker, David D; Chen, Sixue; Zhu, Ning

    2015-04-01

    When citrate ligands-capped gold nanoparticles are mixed with blood sera, a protein corona is formed on the nanoparticle surface due to the adsorption of various proteins in the blood to the nanoparticles. Using a two-step gold nanoparticle-enabled dynamic light scattering assay, we discovered that the amount of human immunoglobulin G (IgG) in the gold nanoparticle protein corona is increased in prostate cancer patients compared to noncancer controls. Two pilot studies conducted on blood serum samples collected at Florida Hospital and obtained from Prostate Cancer Biorespository Network (PCBN) revealed that the test has a 90-95% specificity and 50% sensitivity in detecting early stage prostate cancer, representing a significant improvement over the current PSA test. The increased amount of human IgG found in the protein corona is believed to be associated with the autoantibodies produced in cancer patients as part of the immunodefense against tumor. Proteomic analysis of the nanoparticle protein corona revealed molecular profile differences between cancer and noncancer serum samples. Autoantibodies and natural antibodies produced in cancer patients in response to tumorigenesis have been found and detected in the blood of many cancer types. The test may be applicable for early detection and risk assessment of a broad spectrum of cancer. This new blood test is simple, low cost, requires only a few drops of blood sample, and the results are obtained within minutes. The test is well suited for screening purpose. More extensive studies are being conducted to further evaluate and validate the clinical potential of the new test.

  16. 42 CFR 84.205 - Facepiece test; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...; (ii) Two minutes, calisthenic arm movements; (iii) Two minutes, running in place; and (iv) Two minutes, pumping with a tire pump into a 28-liter (1 cubic-foot) container. (4) Each wearer shall not detect the...

  17. Detection and decay rates of prey and prey symbionts in the gut of a predator through metagenomics.

    PubMed

    Paula, Débora P; Linard, Benjamin; Andow, David A; Sujii, Edison R; Pires, Carmen S S; Vogler, Alfried P

    2015-07-01

    DNA methods are useful to identify ingested prey items from the gut of predators, but reliable detection is hampered by low amounts of degraded DNA. PCR-based methods can retrieve minute amounts of starting material but suffer from amplification biases and cross-reactions with the predator and related species genomes. Here, we use PCR-free direct shotgun sequencing of total DNA isolated from the gut of the harlequin ladybird Harmonia axyridis at five time points after feeding on a single pea aphid Acyrthosiphon pisum. Sequence reads were matched to three reference databases: Insecta mitogenomes of 587 species, including H. axyridis sequenced here; A. pisum nuclear genome scaffolds; and scaffolds and complete genomes of 13 potential bacterial symbionts. Immediately after feeding, multicopy mtDNA of A. pisum was detected in tens of reads, while hundreds of matches to nuclear scaffolds were detected. Aphid nuclear DNA and mtDNA decayed at similar rates (0.281 and 0.11 h(-1) respectively), and the detectability periods were 32.7 and 23.1 h. Metagenomic sequencing also revealed thousands of reads of the obligate Buchnera aphidicola and facultative Regiella insecticola aphid symbionts, which showed exponential decay rates significantly faster than aphid DNA (0.694 and 0.80 h(-1) , respectively). However, the facultative aphid symbionts Hamiltonella defensa, Arsenophonus spp. and Serratia symbiotica showed an unexpected temporary increase in population size by 1-2 orders of magnitude in the predator guts before declining. Metagenomics is a powerful tool that can reveal complex relationships and the dynamics of interactions among predators, prey and their symbionts. © 2014 John Wiley & Sons Ltd.

  18. Physical activity levels at work and outside of work among Commercial Construction Workers

    PubMed Central

    Arias, Oscar E.; Caban-Martinez, Alberto J.; Umukoro, Peter E.; Okechukwu, Cassandra A.; Dennerlein, Jack T.

    2015-01-01

    Objective Characterize the number of minutes of moderate and vigorous physical activity at work and outside of work during seven consecutive days, in a sample of 55 commercial construction workers. Methods Workers wore accelerometers during work and outside work hours for seven consecutive days, and completed brief survey at the seventh day of data collection. Results From the directly measured physical activity, the average number per participant of moderate minutes of occupational physical activity and physical activity outside of work obtained in short bouts were 243 minutes (65%) and 130 minutes (35%), respectively. Directly measured minutes of vigorous occupational physical activity were significant and positively correlated with self-reported fatigue. Conclusions Among commercial construction workers, physical activity from work contributes significantly, approximately 2/3, towards a workers total amount of weekly minutes of moderate physical activity. PMID:25563543

  19. Comparison of the detection of periodontal pathogens in bacteraemia after tooth brushing by culture and molecular techniques.

    PubMed

    Marín, M-J; Figuero, E; González, I; O'Connor, A; Diz, P; Álvarez, M; Herrera, D; Sanz, M

    2016-05-01

    The prevalence and amounts of periodontal pathogens detected in bacteraemia samples after tooth brushing-induced by means of four diagnostic technique, three based on culture and one in a molecular-based technique, have been compared in this study. Blood samples were collected from thirty-six subjects with different periodontal status (17 were healthy, 10 with gingivitis and 9 with periodontitis) at baseline and 2 minutes after tooth brushing. Each sample was analyzed by three culture-based methods [direct anaerobic culturing (DAC), hemo-culture (BACTEC), and lysis-centrifugation (LC)] and one molecular-based technique [quantitative polymerase chain reaction (qPCR)]. With culture any bacterial isolate was detected and quantified, while with qPCR only Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were detected and quantified. Descriptive analyses, ANOVA and Chi-squared tests, were performed. Neither BACTEC nor qPCR detected any type of bacteria in the blood samples. Only LC (2.7%) and DAC (8.3%) detected bacteraemia, although not in the same patients. Fusobacterium nucleatum was the most frequently detected bacterial species. The disparity in the results when the same samples were analyzed with four different microbiological detection methods highlights the need for a proper validation of the methodology to detect periodontal pathogens in bacteraemia samples, mainly when the presence of periodontal pathogens in blood samples after tooth brushing was very seldom.

  20. How Active Are Your Students? Increasing Physical Activity in Schools

    ERIC Educational Resources Information Center

    Avery, Marybell; Brandt, Janet

    2010-01-01

    The U. S. Department of Health and Human Services recommends that youth engage in at least 60 minutes of physical activity each day, most of which should be either moderate- or vigorous-intensity aerobic physical activity. Half of this amount (30 minutes) should be achieved during the school day. NASPE provides guidance in the form of a…

  1. Ability of a 5-minute electrocardiography (ECG) for predicting arrhythmias in Doberman Pinschers with cardiomyopathy in comparison with a 24-hour ambulatory ECG.

    PubMed

    Wess, G; Schulze, A; Geraghty, N; Hartmann, K

    2010-01-01

    Ventricular premature contractions (VPCs) are common in the occult stage of cardiomyopathy in Doberman Pinschers. Although the gold standard for detecting arrhythmia is the 24-hour ambulatory electrocardiography (ECG) (Holter), this method is more expensive, time-consuming and often not as readily available as common ECG. Comparison of 5-minute ECGs with Holter examinations. Eight hundred and seventy-five 5-minute ECGs and Holter examinations of 431 Doberman Pinschers. Each examination included a 5-minute ECG and Holter examination. A cut-off value of > 100 VPCs/24 hours using Holter was considered diagnostic for the presence of cardiomyopathy. Statistical evaluation included calculation of sensitivity, specificity, positive predictive value, and negative predictive value. Holter examinations revealed > 100 VPCs/24 hours in 204/875 examinations. At least 1 VPC during a 5-minute ECG was detected in 131 (64.2%) of these 204 examinations. No VPCs were found in the 5-minute ECG in 73 (35.8%) examinations of affected Doberman Pinschers. A 5-minute ECG with at least 1 VPC as cut-off had a sensitivity of 64.2%, a specificity of 96.7%, a positive predictive value of 85.6% and a negative predictive value of 89.9% for the presence of > 100 VPCs/24 hours. A 5-minute ECG is a rather insensitive method for detecting arrhythmias in Doberman Pinschers. However, the occurrence of at least 1 VPC in 5 minutes strongly warrants further examination of the dog, because specificity (96.7%) and positive predictive value (85.6%) are high and could suggest occult cardiomyopathy.

  2. Antigen detection at atomolar concentration using optical tweezers

    NASA Astrophysics Data System (ADS)

    Laliberté, Mathieu; Bordeleau, François; Marceau, Normand; Sheng, Yunlong

    2009-06-01

    Methods that avoid intermediate amplification steps to detect protein markers of pathological disturbances would be of wide interest in the clinical environment. This is particularly the case in cancer diagnosis, where protein fragments are released into the blood by the emerging cancer cells. These fragments generate an antigen-antibody reaction, and the concentration of the antigen is known to modulate this interaction. Here we report on the development of a novel optical tweezers-based procedure to measure minute amount of antigen in a biological fluid. The force was applied on a 3μm polystyrene bead coated with Bovine Serum Albumin (BSA) attached on a 1.5 μm diameter borosilicate rod tip coated with anti-BSA antibody. First, we verified that the binding strength was dependent on the protein concentration on the bead. We then assessed the sensitivity range by finding the minimal BSA concentration in solution that can still interfere with the bead-rod linkage. On the whole, the results demonstrated that proteinous antigen present in a biological fluid could possibly be detectable at atomolar concentration through the use of an optical tweezers.

  3. 1997 Leonid Shower From Space

    NASA Technical Reports Server (NTRS)

    Jenniskens, Peter; Nugent, David; Murthy, Jayant; Tedesco, Ed; DeVincenzi, Donal L. (Technical Monitor)

    2000-01-01

    In November 1997, the Midcourse Space Experiment satellite (MSX) was deployed to observe the Leonid shower from space. The shower lived up to expectations, with abundant bright fireballs. Twenty-nine meteors were detected by a wide-angle, visible wavelength, camera near the limb of the Earth in a 48-minute interval, and three meteors by the narrow field camera. This amounts to a meteoroid influx of 5.5 +/- 0.6 10(exp -5)/sq km hr for masses greater than 0.3 gram. The limiting magnitude for limb observations of Leonid meteors was measured at M(sub v) = -1.5 magn The Leonid shower magnitude population index was 1.6 +/- 0.2 down to M(sub v) = -7 magn., with no sign of an upper mass cut-off.

  4. DELAYED HYPERSENSITIVITY

    PubMed Central

    Uhr, Jonathan W.; Salvin, S. B.; Pappenheimer, A. M.

    1957-01-01

    A general method for induction of the delayed hypersensitive state directed against single protein antigens is described. The method consists of intradermal injection of minute amounts of washed immune precipitates containing the antigen in question. Provided the specific precipitates are formed in the region of antibody excess, maximal sensitivity develops at least 2 to 3 weeks before detectable circulating antibody is formed in guinea pigs against the sensitizing antigen. Neither adjuvant nor killed acid-fast bacteria are required for induction of the delayed hypersensitive state although the degree of sensitization is considerably increased when the sensitizing material is incorporated in Freund's complete adjuvant. Characteristics of the "delayed" as opposed to the "immediate" hypersensitive states in the guinea pig are described and implications of the findings are discussed. PMID:13385403

  5. The cost of medical education in an ambulatory neurology clinic.

    PubMed Central

    Abramovitch, Anna; Newman, William; Padaliya, Bimal; Gill, Chandler; Charles, P. David

    2005-01-01

    Decreased revenue from clinical services has required academic hospitals and physicians to improve productivity. Medical student education may be a significant hindrance to increased productivity and income. This study quantifies the amount of time spent by faculty members teaching medical students in an ambulatory neurology clinic as well as the amount of time students occupied rooms when seeing patients on their own. Over a three-week period in an ambulatory neurology clinic, an observer noted these quantities of time, and the opportunity costs of both amounts of time were determined. Attending physicians spent an average of 19.6 minutes per medical student per half-day teaching, which translates to an average cost of $20.78 per half-day clinic. Students spent an average of 49.9 minutes per half-day seeing patients in the absence of an attending physician, an opportunity cost to the clinic of $142.50 per student per half-day. PMID:16296220

  6. Withdrawal times and associated factors in colonoscopy: a quality assurance multicenter assessment.

    PubMed

    Overholt, Bergein F; Brooks-Belli, Linda; Grace, Michael; Rankin, Kristin; Harrell, Royce; Turyk, Mary; Rosenberg, Fred B; Barish, Robert W; Gilinsky, Norman H

    2010-04-01

    To evaluate the use and impact of the recommended withdrawal time of at least 6 minutes from the cecum in colonoscopy in multiple gastroenterology endoscopy ambulatory surgery centers serving a wide geographical area. An observational prospective multicenter quality assurance review was conducted in 49 ambulatory surgery centers in 17 states with 315 gastroenterologists. There was no intervention with this quality assessment program as care of patients and the routine of gastroenterologists continued as standard practice. Multivariable analysis was applied to the database to examine factors affecting withdrawal time and polyp detection. There were 15,955 consecutive qualified patients receiving colonoscopies in a designated 4-week period. Gastroenterologists with average withdrawal times of 6 minutes or more in patients with no polyps were 1.8 times more likely to detect 1 or more polyps and had a significantly higher rate (P<0.0001) of polyp detection in patients with findings of polyps compared to gastroenterologists with average withdrawal times of less than 6 minutes in patients with no polyps. For patients with no pathology, the mean time of withdrawal was 6.98 (SD=4.34) minutes and for patients with pathology mean time of withdrawal was 11.27 (SD=6.71) minutes. Strongest predictors of withdrawal time of 6 minutes or more were presence of carcinoma (3.7 times more likely than those with no pathology), adenoma (2.0 times more likely than those with no pathology), and number of polyps visualized (1.7 times more likely for each polyp). This quality assurance assessment from standard colonoscopy practices of 315 gastroenterologists in 49 endoscopic ambulatory surgery centers serving a wide geographical area provides support for the merits of a colonoscopy withdrawal time from the cecum of 6 minutes or more to improve the detection of polyps.

  7. Application of Radar-Based Accumulated Rainfall Products for Early Detection of Heavy Rainfall Occurrence

    NASA Astrophysics Data System (ADS)

    Nishiyama, K.; Wakimizu, K.; Yokota, I.; Tsukahara, K.; Moriyama, T.

    2016-12-01

    In Japan, river and debris flow disasters have been frequently caused by heavy rainfall occurrence under the influence of the activity of a stationary front and associated inflow of a large amount of moisture into the front. However, it is very difficult to predict numerically-based heavy rainfall and associated landslide accurately. Therefore, the use of meteorological radar information is required for enhancing decision-making ability to urge the evacuation of local residents by local government staffs prior to the occurrence of the heavy rainfall disaster. It is also desirable that the local residents acquire the ability to determine the evacuation immediately after confirming radar information by themselves. Actually, it is difficult for untrained local residents and local government staffs to easily recognize where heavy rainfall occurs locally for a couple of hours. This reason is that the image of radar echoes is equivalent to instant electromagnetic distribution measured per a couple of minutes, and the distribution of the radar echoes moves together with the movement of a synoptic system. Therefore, in this study, considering that the movement of radar echoes also may stop in a specific area if stationary front system becomes dominant, radar-based accumulated rainfall information is defined here. The rainfall product is derived by the integration of radar intensity measured every ten minutes during previous 1 hours. Using this product, it was investigated whether and how the radar-based accumulated rainfall displayed at an interval of ten minutes can be applied for early detection of heavy rainfall occurrence. The results are summarized as follows. 1) Radar-based accumulated rainfall products could confirm that some of stationary heavy rainfall systems had already appeared prior to disaster occurrence, and clearly identify the movement of heavy rainfall area. 2) Moreover, accumulated area of rainfall could be visually and easily identified, compared with time-series (movie) of real-time radar-based rainfall intensity. Therefore, the accumulated rainfall distribution provides effective information for early detection of heavy rainfall causing disasters through the training of local residents and local government staffs who have no meteorologically-technical knowledge.

  8. Transport of Indole-3-Acetic Acid during Gravitropism in Intact Maize Coleoptiles 1

    PubMed Central

    Parker, Karen E.; Briggs, Winslow R.

    1990-01-01

    We have investigated the transport of tritiated indole-3-acetic acid (IAA) in intact, red light-grown maize (Zea mays) coleoptiles during gravitropic induction and the subsequent development of curvature. This auxin is transported down the length of gravistimulated coleoptiles at a rate comparable to that in normal, upright plants. Transport is initially symmetrical across the coleoptile, but between 30 and 40 minutes after plants are turned horizontal a lateral redistribution of the IAA already present in the transport stream occurs. By 60 minutes after the beginning of the gravitropic stimulus, the ratio of tritiated tracer auxin in the lower half with respect to the upper half is approximately 2:1. The redistribution of growth that causes gravitropic curvature follows the IAA redistribution by 5 or 10 minutes at the minimum in most regions of the coleoptile. Immobilization of tracer auxin from the transport stream during gravitropism was not detectable in the most apical 10 millimeters. Previous reports have shown that in intact, red light-grown maize coleoptiles, endogenous auxin is limiting for growth, the tissue is linearly responsive to linearly increasing concentrations of small amounts of added auxin, and the lag time for the stimulation of straight growth by added IAA is approximately 8 or 9 minutes (TI Baskin, M Iino, PB Green, WR Briggs [1985] Plant Cell Environ 8: 595-603; TI Baskin, WR Briggs, M Iino [1986] Plant Physiol 81: 306-309). We conclude that redistribution of IAA in the transport stream occurs in maize coleoptiles during gravitropism, and is sufficient in degree and timing to be the immediate cause of gravitropic curvature. PMID:16667914

  9. AIP1OGREN: Aerosol Observing Station Intensive Properties Value-Added Product

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koontz, Annette; Flynn, Connor

    The aip1ogren value-added product (VAP) computes several aerosol intensive properties. It requires as input calibrated, corrected, aerosol extensive properties (scattering and absorption coefficients, primarily) from the Aerosol Observing Station (AOS). Aerosol extensive properties depend on both the nature of the aerosol and the amount of the aerosol. We compute several properties as relationships between the various extensive properties. These intensive properties are independent of aerosol amount and instead relate to intrinsic properties of the aerosol itself. Along with the original extensive properties we report aerosol single-scattering albedo, hemispheric backscatter fraction, asymmetry parameter, and Ångström exponent for scattering and absorption withmore » one-minute averaging. An hourly averaged file is produced from the 1-minute files that includes all extensive and intensive properties as well as submicron scattering and submicron absorption fractions. Finally, in both the minutely and hourly files the aerosol radiative forcing efficiency is provided.« less

  10. Effect of Green Coffee Consumption on Resting Energy Expenditure, Blood Pressure, and Body Temperature in Healthy Women: A Pilot Study.

    PubMed

    Acar-Tek, Nilüfer; Aǧagündüz, Duygu; Ayhan, Büşra

    2018-05-03

    This study was conducted to determine the effects of green coffee consumption on resting energy expenditures (REEs), blood pressure, and body temperature of individuals. The study was conducted with 24 women. The REE values of the individuals were measured with the COSMED Fitmate PRO. After the first REE measurements, individuals were given 1 cup of green coffee that was prepared to contain 6 mg caffeine per kg of lean body mass. After coffee consumption, REE measurements were made at 30, 60, 120, and 180 minutes. Blood pressure (mm Hg) and body temperature values (°C) were measured simultaneously with REE measurement. There was a positive correlation between the caffeine amounts given with green coffee and 30-minute (p < 0.05), 60-minute (p = 0.06), and 120-minute (p < 0.05) REE (kcal/d) values. There was also a positive correlation between the total chlorogenic acid taken with green coffee and 30-minute (p < 0.05), 60-minute (p = 0.06), and 120-minute (p < 0.05) REE (kcal/d) values. The intracellular and extracellular fluid amounts liter(l) before and after consumption of green coffee by individuals were 18.7 ± 1.57 versus 18.6 ± 1.44 (p < 0.05) and 11.4 ± 1.01 versus 11.2 ± 0.97 (p < 0.05), respectively. The body temperature (°C) changes observed in the individuals whose usual dietary caffeine intake was less than or equal to the 50th percentile after green coffee consumption were statistically significant (p < 0.05). Similarly, the diastolic blood pressure changes observed in the individuals whose usual dietary caffeine intake was less than or equal to the 50th percentile after green coffee consumption was almost statistically significant (p = 0.06). The results of this study showed that 6 mg caffeine/kg (lean body mass) intake among women changed body temperature and blood pressure values and liquid balance depending on the usual dietary coffee intake. In addition, chlorogenic acid is also correlated with REE values besides green coffee caffeine. Key teaching points • There are several findings, and chlorogenic acid may have antihypertensive effects. • There is a significant correlation between green coffee chlorogenic acid amount and REE. • Intracellular and extracellular liquid amounts decrease following green coffee consumption (215-280 mg caffeine), and these changes are observed in individuals whose usual dietary caffeine intake is relatively both low and high. • The body temperature values of individuals whose usual dietary caffeine intake was in the 50th percentile or greater (relatively high) increased after green coffee consumption.

  11. Early Detection of Physical Activity for People With Type 1 Diabetes Mellitus.

    PubMed

    Dasanayake, Isuru S; Bevier, Wendy C; Castorino, Kristin; Pinsker, Jordan E; Seborg, Dale E; Doyle, Francis J; Dassau, Eyal

    2015-06-30

    Early detection of exercise in individuals with type 1 diabetes mellitus (T1DM) may allow changes in therapy to prevent hypoglycemia. Currently there is limited experience with automated methods that detect the onset and end of exercise in this population. We sought to develop a novel method to quickly and reliably detect the onset and end of exercise in these individuals before significant changes in blood glucose (BG) occur. Sixteen adults with T1DM were studied as outpatients using a diary, accelerometer, heart rate monitor, and continuous glucose monitor for 2 days. These data were used to develop a principal component analysis based exercise detection method. Subjects also performed 60 and 30 minute exercise sessions at 30% and 50% predicted heart rate reserve (HRR), respectively. The detection method was applied to the exercise sessions to determine how quickly the detection of start and end of exercise occurred relative to change in BG. Mild 30% HRR and moderate 50% HRR exercise onset was identified in 6 ± 3 and 5 ± 2 (mean ± SD) minutes, while completion was detected in 3 ± 8 and 6 ± 5 minutes, respectively. BG change from start of exercise to detection time was 1 ± 6 and -1 ± 3 mg/dL, and, from the end of exercise to detection time was 6 ± 4 and -17 ± 13 mg/dL, respectively, for the 2 exercise sessions. False positive and negative ratios were 4 ± 2% and 21 ± 22%. The novel method for exercise detection identified the onset and end of exercise in approximately 5 minutes, with an average BG change of only -6 mg/dL. © 2015 Diabetes Technology Society.

  12. Relationship between the type and amount of physical activity and low back pain in Koreans aged 50 years and older.

    PubMed

    Kim, Won; Jin, Young Soo; Lee, Choon Sung; Hwang, Chang Ju; Lee, Sang Yoon; Chung, Sun G; Choi, Kyoung Hyo

    2014-10-01

    To examine the association between the type and amount of physical activity (PA) and low back pain (LBP) in people aged ≥50 years. Cross-sectional study. A nationwide survey. Data were obtained from the Fifth Korea National Health and Nutrition Examination Survey, which was conducted in 2010 and 2011. Overall, 1796 men and 2198 women aged ≥50 years were included. PA was categorized as vigorous, moderate, walking, strength exercises, or flexibility exercises. The total amount of PA was presented as quartiles of the total metabolic equivalent (MET)-minutes/week based on the PA questionnaire. Multivariate logistic regression analysis was performed to examine associations between LBP and the type and amount of PA. Odds ratio for LBP according to the type of PA and the quartiles of the total MET-minutes/week. After adjusting for age and body mass index, vigorous and moderate PA were associated with an increased risk of LBP in both men and women, whereas strength exercises were associated with a reduced risk of LBP. These associations were maintained after adjusting for all potential confounders. Subgroup analysis according to age revealed that these trends were most significantly demonstrated in women aged ≥65 years. The PA quartiles for total MET-minutes/week for men showed a U-shaped association with LBP, whereas only the fourth PA quartile for women showed an increased risk of LBP compared with the second quartile. These results suggest that both the type and amount of PA affect the development of LBP in people aged ≥50 years and thus activity modification might be helpful for prevention and management of LBP. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  13. Using EHR Data to Detect Prescribing Errors in Rapidly Discontinued Medication Orders.

    PubMed

    Burlison, Jonathan D; McDaniel, Robert B; Baker, Donald K; Hasan, Murad; Robertson, Jennifer J; Howard, Scott C; Hoffman, James M

    2018-01-01

    Previous research developed a new method for locating prescribing errors in rapidly discontinued electronic medication orders. Although effective, the prospective design of that research hinders its feasibility for regular use. Our objectives were to assess a method to retrospectively detect prescribing errors, to characterize the identified errors, and to identify potential improvement opportunities. Electronically submitted medication orders from 28 randomly selected days that were discontinued within 120 minutes of submission were reviewed and categorized as most likely errors, nonerrors, or not enough information to determine status. Identified errors were evaluated by amount of time elapsed from original submission to discontinuation, error type, staff position, and potential clinical significance. Pearson's chi-square test was used to compare rates of errors across prescriber types. In all, 147 errors were identified in 305 medication orders. The method was most effective for orders that were discontinued within 90 minutes. Duplicate orders were most common; physicians in training had the highest error rate ( p  < 0.001), and 24 errors were potentially clinically significant. None of the errors were voluntarily reported. It is possible to identify prescribing errors in rapidly discontinued medication orders by using retrospective methods that do not require interrupting prescribers to discuss order details. Future research could validate our methods in different clinical settings. Regular use of this measure could help determine the causes of prescribing errors, track performance, and identify and evaluate interventions to improve prescribing systems and processes. Schattauer GmbH Stuttgart.

  14. Identifying Care Coordination Interventions Provided to Community-Dwelling Older Adults Using Electronic Health Records

    PubMed Central

    Kim, Tae Youn; Marek, Karen D.; Coenen, Amy

    2016-01-01

    Although care coordination is a popular intervention, there is no standard method of delivery. Also little is known about who most benefits or characteristics that predict the amount of care coordination needed, especially with chronically ill older adults. The purpose of this study was to identify types and amount of nurse care coordination interventions provided to 231 chronically ill older adults who participated in a 12-month home care medication management program in the Midwestern. For each participant, the nurse care coordinator spent an average of 134 minutes/month providing in-person home care, 48 minutes/month of travel, and 18 minutes/month of indirect care occurring outside the home visit. This accounted for 67.2%, 23.8%, and 9.0% of nursing time respectively for home visits, travel, and indirect care. Four of 11 nursing interventions focused on medication management were provided to all participants. Seven of the 11 main interventions were individualized according to each person’s special needs. Wide variations were observed in time provided with in-person home care and communications with multiple stakeholders. Study findings indicate the importance of individualizing interventions and the variability in the amount of nursing time needed to provide care coordination to chronically ill older adults. PMID:26985762

  15. Time spent by people managing chronic obstructive pulmonary disease indicates biographical disruption

    PubMed Central

    Jowsey, Tanisha; Yen, Laurann E; Bagheri, Nasser; McRae, Ian S

    2014-01-01

    Since Bury’s 1982 proposal that chronic illness creates biographical disruption for those who are living with it, there has been no effort to quantitatively measure such disruption. “Biographical disruption” refers to the substantial and directive influence that chronic illness can have over the course of a person’s life. Qualitative research and time use studies have demonstrated that people with chronic illnesses spend considerable amounts of time managing their health, and that these demands may change over time. This study was designed to measure the time that older people with chronic illnesses spend on selected health practices as one indicator of biographical disruption. We look specifically at the time use of people with chronic obstructive pulmonary disease (COPD). As part of a larger time use survey, a recall questionnaire was mailed to 3,100 members of Lung Foundation Australia in 2011. A total of 681 responses were received (22.0% response rate), 611 of which were from people with COPD. Descriptive analyses were undertaken on the amount of time spent on selected health-related activities including personal care, nonclinical health-related care, and activity relating to health services. Almost all people with COPD report spending some time each day on personal or home-based health-related tasks, with a median time of 15 minutes per day spent on these activities. At the median, people also report spending about 30 minutes per day exercising, 2.2 hours per month (the equivalent of 4.4 minutes per day) on nonclinical health-related activities, and 4.1 hours per month (equivalent to 8.2 minutes per day) on clinical activities. Excluding exercise, the median total time spent on health-related activities was 17.8 hours per month (or 35.6 minutes per day). For people in the top 10% of time use, the total amount of time was more than 64.6 hours per month (or 2.2 hours per day) excluding exercise, and 104 hours per month (or 3.5 hours per day) including exercise. The amount of time spent on health-related activity, such as engaging in personal care tasks, may be regular and predictable. The execution of these tasks generally takes relatively small amounts of time, and might be incorporated into daily life (biography) without causing significant disruption. Other activities may require large blocks of time, and they may be disruptive in a practical way that almost inevitably disrupts biography. The amount of time required does not appear to alter in relation to the time since diagnosis. The scale of time needed to manage one’s health could easily be interpreted as disruptive, and for some people, even overwhelming. PMID:24477271

  16. Amount of Time to Eat Lunch Is Associated with Children's Selection and Consumption of School Meal Entrée, Fruits, Vegetables, and Milk.

    PubMed

    Cohen, Juliana F W; Jahn, Jaquelyn L; Richardson, Scott; Cluggish, Sarah A; Parker, Ellen; Rimm, Eric B

    2016-01-01

    There are currently no national standards for school lunch period length and little is known about the association between the amount of time students have to eat and school food selection and consumption. Our aim was to examine plate-waste measurements from students in the control arm of the Modifying Eating and Lifestyles at School study (2011 to 2012 school year) to determine the association between amount of time to eat and school meal selection and consumption. We used a prospective study design using up to six repeated measures among students during the school year. One thousand and one students in grades 3 to 8 attending six participating elementary and middle schools in an urban, low-income school district where lunch period lengths varied from 20 to 30 minutes were included. School food selection and consumption were collected using plate-waste methodology. Logistic regression and mixed-model analysis of variance was used to examine food selection and consumption. Compared with meal-component selection when students had at least 25 minutes to eat, students were significantly less likely to select a fruit (44% vs 57%; P<0.0001) when they had <20 minutes to eat. There were no significant differences in entrée, milk, or vegetable selections. Among those who selected a meal component, students with <20 minutes to eat consumed 13% less of their entrée (P<0.0001), 10% less of their milk (P<0.0001), and 12% less of their vegetable (P<0.0001) compared with students who had at least 25 minutes to eat. During the school year, a substantial number of students had insufficient time to eat, which was associated with significantly decreased entrée, milk, and vegetable consumption compared with students who had more time to eat. School policies that encourage lunches with at least 25 minutes of seated time might reduce food waste and improve dietary intake. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  17. Hyperforin Accumulates in the Translucent Glands of Hypericum perforatum

    PubMed Central

    Soelberg, Jens; Jørgensen, Lise Bolt; Jäger, Anna K.

    2007-01-01

    Background and Aims Hypericum perforatum contains the therapeutically important compounds hypericin and hyperforin. Hypericin is known to accumulate in the dark glands. This investigation aimed to determine the accumulation site of hyperforin. Methods Dark and translucent glands as well as non-secretory tissue in leaves were manually isolated under the microscope. Hyperforin content was quantified by UV HPLC. Secretory structures were surveyed anatomically. Key Results The hyperforin content of intact leaves was found to be about 3 mg g−1 fresh tissue, whereas a content of about 7 mg g−1 fresh material was found in isolated translucent glands. Hyperforin was found only to occur in minute amounts in dark glands (approx. 0·4 mg g−1 fresh tissue). In non-secretory tissue no hyperforin was detected. Conclusions The accumulation of hyperforin detected in the translucent glands supports the proposed hypothesis that hyperforin is synthesized by the same biosynthetic machinery as monoterpenes in the chloroplasts of cells delimiting the gland. PMID:17468113

  18. Ad-hoc surface-enhanced Raman spectroscopy methodologies for the detection of artist dyestuffs: thin layer chromatography-surface enhanced Raman spectroscopy and in situ on the fiber analysis.

    PubMed

    Brosseau, Christa L; Gambardella, Alessa; Casadio, Francesca; Grzywacz, Cecily M; Wouters, Jan; Van Duyne, Richard P

    2009-04-15

    Tailored ad-hoc methods must be developed for successful identification of minute amounts of natural dyes on works of art using Surface-Enhanced Raman Spectroscopy (SERS). This article details two of these successful approaches using silver film over nanosphere (AgFON) substrates and silica gel coupled with citrate-reduced Ag colloids. The latter substrate functions as the test system for the coupling of thin-layer chromatography and SERS (TLC-SERS), which has been used in the current research to separate and characterize a mixture of several artists' dyes. The poor limit of detection of TLC is overcome by coupling with SERS, and dyes which co-elute to nearly the same spot can be distinguished from each other. In addition, in situ extractionless non-hydrolysis SERS was used to analyze dyed reference fibers, as well as historical textile fibers. Colorants such as alizarin, purpurin, carminic acid, lac dye, crocin, and Cape jasmine were thus successfully identified.

  19. Evaluation and Characterization of Nutritive Properties of the Jelly Ear Culinary-Medicinal Mushroom Auricularia auricula-judae (Agaricomycetes) from Nigeria.

    PubMed

    Ohiri, Reginald Chibueze; Bassey, Essien Eka

    2017-01-01

    This study investigated the nutritive properties of the culinary-medicinal mushroom Auricularia auricula- judae. From the analysis, among the major minerals, potassium was found in the highest concentration, with a value of 172.03 ± 8.62 mg/kg, whereas manganese had the highest concentration among trace elements, with a value of 1.66 ± 0.11 mg/kg. Glutamic acid was the amino acid detected in the largest amounts in this study, with a value of 10.09 ± 1.86 mg/kg. Although glutamine and asparagine were not detected in this mushroom, cysteine and methionine had the lowest concentrations, with values of 0.34 ± 0.01 and 0.80 ± 0.03 mg/kg, respectively. The predominant oil was 9,12-octadecadienoic acid (Z,Z)methyl ester, with retention times of 21.246 and 21.715 minutes, and comprising percentages of the total of 4.309 and 47.385, respectively.

  20. An optical technique for detecting minute-amplitude standing waves on a liquid jet

    NASA Astrophysics Data System (ADS)

    Takahashi, I.; Mori, Y. H.

    1995-10-01

    A liquid jet emerging from a nozzle or an orifice whose outlet is slightly elliptic has a series of minute-amplitude waves on its surface. A quite simple technique is proposed which enables detecting such waves even if they are no longer recognizable with the aid of ordinary backlighting of the jet.

  1. 30 CFR 260.102 - What definitions apply to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... United States, as specified in the lease, in the amount or value of the production saved, removed, or..., in the amount or value of the production saved, removed, or sold. OCS lease sale means the Department... minutes West longitude. (See part 203 of this title.) Production period means the period during which the...

  2. Measurement of acute toxicity to Mysidopsis bahia using DaphniaQuant{reg_sign} instrument and protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blankemeyer, J.T.; Nguyen, T.; Burks, S.L.

    1994-12-31

    DaphniaQuant{reg_sign} uses a fluorescent dye to permeate the cells of aquatic organisms. The technique has been used on frog embryos, fish embryos, and bovine erythrocytes. Two wavelengths of light are used to excite the fluorescent dye, Di-4-ANEPPS. The blue excitation wavelength measures the cell membrane potential while the yellow excitation wavelength measures the amount of dye loaded into the organisms. The authors applied the technique to the shrimp, Mysidopsis bahia, used in marine toxicity testing. The authors used from 1 to 10 shrimp, loaded into a 3 ml spectrofluorometry plastic cuvette. The fluorescent dye, Di-4-ANEPPS, was mixed with the 3more » ml of ASW in the cuvette at a final Di-4ANEPPS concentration of 10{sub {minus}6} M. After a thirty minute incubation, the fluorescence of Di-4-ANEPPS was measured in the DaphniaQuant{reg_sign} instrument. A similar protocol was used to test various concentrations of standard assay chemicals and effluents. The test chemical was mixed with ASW and Di-4-ANEPPS and incubated with the shrimp for thirty minutes. After thirty minutes, the fluorescence was measured and compared to the fluorescence of the control shrimp. The authors found that the fluorescence from a single shrimp was detectable and gave similar toxicity data as did the replicates using 10 shrimp. They conclude that the DaphniaQuant{reg_sign} assay can be successfully adapted to marine organisms, particularly Mysidopsis bahia.« less

  3. Double minute chromosomes in mouse methotrexate-resistant cells studied by atomic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng Xinyu; Zhang Liangyu; Zhang Yu

    2006-08-11

    Double minute chromosomes (DMs) are acentric, autonomously replicating extra-chromosomes and frequently mediate gene amplification in tumor and drug resistant cells. Atomic force microscopy (AFM) is a powerful tool in microbiology. We used AFM to explore the ultrastructure of DMs in mouse fibroblasts 3T3R500. DMs in various phases of cell cycle were also studied in order to elucidate the mechanisms of their duplication and separation. Metaphase spread and induced premature condensed chromosomes (PCCs) were observed under the AFM. DMs were detected to be composed of two compact spheres linked by fibers. The fibers of DMs directly connected with metaphase chromosomes weremore » observed. Many single-minutes and few DMs were detected in G1 PCCs, while more DMs were detected in S PCCs than in G1 PCCs. Besides, all of the DMs in G2 PCCs were coupled. Our present results suggested that DMs might divide into single-minutes during or before G1-phase, followed by duplication of the single-minutes in S-phase. Moreover, we introduced a new powerful tool to study DMs and got some ideal results.« less

  4. Fire Detection Using tin Oxide Gas Sensors Installed in an Indoor Space

    NASA Astrophysics Data System (ADS)

    Shibata, Shin-Ichi; Higashino, Tsubasa; Sawada, Ayako; Oyabu, Takashi; Takei, Yoshinori; Nanto, Hidehito; Toko, Kiyoshi

    Many lives and facilities were lost by fire. Especially, there are many damages to elderly, toddlers and babies. In Japan, number of deaths over 65 years old reached to 53% in 2004. Number of over 81 years olds went to 20%. It takes for the elderly person more time to sense fire and also to evacuate to safe places. Although it is important to prevent the fire, it also needs to inform the fire breaking as early as possible. Human sense decreases with age and it is difficult to perceive the fire at an early stage. It is desired to develop a higher sensitive element for fire and its system which can detect fire at an early stage. In this experiment, tin oxide gas sensors were adopted to detect a smoldering fire at the early stage. Most common case of fire is the smoldering fire. The reliability of the sensor is higher and it is adopted in a gas alarm detector. The sensor can also detect slight amount of odor molecule. In our previous experiment, it became obvious that it was better to install the sensor to the ceiling to detect odor components generating from smoldering fire. Therefore, five sensors were installed in the ceiling away from each other and the method to detect the fire was examined. As a result, a characteristic was newly derived by adding the sensor outputs for one minute. The sensor output was input every 0.1s. The characteristic is called as the integrated characteristic. After that, the differential characteristic was derived using the integrated characteristic. The fire was determined using the differential characteristics. The materials causing a smoldering fire were woodchip, wallpaper and carpet as subjects. The system could detect the fire in several minutes for whole materials. The sensor is effective to detect the smoldering fire at an early stage. It is necessary to detect a cigarette smoke to distinguish as non fire. In this study, the discrimination was also examined using a quadratic function (ax2+b). The coefficients a and b were effective to identify smoldering fire and cigarette smoke. Principal component analysis for the arrival speed S which meant a kind of odor-speed was also useful to distinguish fire from non fire.

  5. The effect of interferon on the receptor sites to rabies virus on mouse neuroblastoma cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briggs, D.J.

    1989-01-01

    The binding of rabies virus to mouse neuroblastoma cells (MNA) primed with alpha interferon (IFN-{alpha}), beta interferon (IFN-{beta}), or alpha bungarotoxin (BTX) was examined. A saturable number of receptor sites to rabies virus was calculated by increasing the amount of {sup 3}H-CVS added to a constant number of untreated MNA cells. MNA cells were then exposed to 20 I.U. of IFN-{alpha}, IFN-{beta}, or 1 {mu}g of BTX and assayed to determine if these treatments had an effect on the number of receptor sites to rabies virus. Total amount of {sup 3}H-CVS bound to MNA cells was determined during a threemore » hour incubation period. Cold competition assays using 1,000 fold excess unlabeled CVS were used to determine non-specific binding for each treatment. Specific binding was then calculated by subtracting non-specific binding from the total amount of CVS bound to MNA cells. A similar amount of total viral protein bound to untreated and IFN-{beta}, and BTX treated cells after 180 minutes of incubation. The bound protein varied by only 0.07 {mu}g. However, the amount of specific and non-specific binding varied a great deal between treatments. BTX caused an increase in non-specific and a decrease in specific binding of rabies virus. IFN-{beta} produced variable results in non-specific and specific binding while IFN-{alpha} caused mainly specific binding to occur. The most significant change brought about by IFN-{alpha} was an increase in the rate of viral attachment. At 30 minutes post-infection, IFN-{alpha} treated cells had bound 90% of the total amount of virus bound to untreated cells after 180 minutes. The increased binding rate did not cause a productive infection of rabies virus. No viral production was evident after an incubation period of 48 hours in either IFN-{alpha} or IFN-{beta} treated cells.« less

  6. [Application of recombinase polymerase amplification in the detection of Pseudomonas aeruginosa].

    PubMed

    Jin, X J; Gong, Y L; Yang, L; Mo, B H; Peng, Y Z; He, P; Zhao, J N; Li, X L

    2018-04-20

    Objective: To establish an optimized method of recombinase polymerase amplification (RPA) to rapidly detect Pseudomonas aeruginosa in clinic. Methods: (1) The DNA templates of one standard Pseudomonas aeruginosa strain was extracted and detected by polymerase chain reaction (PCR), real-time fluorescence quantitative PCR and RPA. Time of sample loading, time of amplification, and time of detection of the three methods were recorded. (2) One standard Pseudomonas aeruginosa strain was diluted in 7 concentrations of 1×10(7,) 1×10(6,) 1×10(5,) 1×10(4,) 1×10(3,) 1×10(2,) and 1×10(1) colony forming unit (CFU)/mL after recovery and cultivation. The DNA templates of Pseudomonas aeruginosa and negative control strain Pseudomonas putida were extracted and detected by PCR, real-time fluorescence quantitative PCR, and RPA separately. The sensitivity of the three methods in detecting Pseudomonas aeruginosa was analyzed. (3) The DNA templates of one standard Pseudomonas aeruginosa strain and four negative control strains ( Staphylococcus aureus, Acinetobacter baumanii, Candida albicans, and Pseudomonas putida ) were extracted separately, and then they were detected by PCR, real-time fluorescence quantitative PCR, and RPA. The specificity of the three methods in detecting Pseudomonas aeruginosa was analyzed. (4) The DNA templates of 28 clinical strains of Pseudomonas aeruginosa preserved in glycerin, 1 clinical strain of which was taken by cotton swab, and negative control strain Pseudomonas putida were extracted separately, and then they were detected by RPA. Positive amplification signals of the clinical strains were observed, and the detection rate was calculated. All experiments were repeated for 3 times. Sensitivity results were analyzed by GraphPad Prism 5.01 statistical software. Results: (1) The loading time of RPA, PCR, and real-time fluorescence quantitative PCR for detecting Pseudomonas aeruginosa were all 20 minutes. In PCR, time of amplification was 98 minutes, time of gel detection was 20 minutes, and the total time was 138 minutes. In real-time fluorescence quantitative PCR, amplification and detection could be completed simultaneously, which took 90 minutes, and the total time was 110 minutes. In RPA, amplification and detection could also be completed simultaneously, which took 15 minutes, and the total time was 35 minutes. (2) Pseudomonas putida did not show positive amplification signals or gel positive results in any of the three detection methods. The detection limit of Pseudomonas aeruginosa in real-time fluorescence quantitative PCR and PCR was 1×10(1) CFU/mL, and that of Pseudomonas aeruginosa in RPA was 1×10(2) CFU/mL. In RPA and real-time fluorescence quantitative PCR, the higher the concentration of Pseudomonas aeruginosa, the shorter threshold time and smaller the number of cycles, namely shorter time for detecting the positive amplified signal. In real-time fluorescence quantitative PCR, all positive amplification signal could be detected when the concentration of Pseudomonas aeruginosa was 1×10(1)-1×10(7) CFU/mL. In RPA, the detection rate of positive amplification signal was 0 when the concentration of Pseudomonas aeruginosa was 1×10(1) CFU/mL, while the detection rate of positive amplification signal was 67% when the concentration of Pseudomonas aeruginosa was 1×10(2) CFU/mL, and the detection rate of positive amplification signal was 100% when the concentration of Pseudomonas aeruginosa was 1×10(3)-1×10(7) CFU/mL. (3) In RPA, PCR, and real-time fluorescence quantitative PCR, Pseudomonas aeruginosa showed positive amplification signals and gel positive results, but there were no positive amplification signals or gel positive results in four negative control strains of Acinetobacter baumannii, Staphylococcus aureus, Candida albicans, and Pseudomonas putida . (4) In RPA, 28 clinical strains of Pseudomonas aeruginosa preserved in glycerin and 1 clinical strain of Pseudomonas aeruginosa taken by cotton swab showed positive amplification signals, while Pseudomonas putida did not show positive amplification signal. The detection rate of positive amplification signal of 29 clinical strains of Pseudomonas aeruginosa in RPA was 100%. Conclusions: The established optimized RPA technology for fast detection of Pseudomonas aeruginosa requires shorter time, with high sensitivity and specificity. It was of great value in fast detection of Pseudomonas aeruginosa infection in clinic.

  7. Massively Parallel Rogue Cell Detection Using Serial Time-Encoded Amplified Microscopy of Inertially Ordered Cells in High-Throughput Flow

    DTIC Science & Technology

    2011-08-01

    screening of budding yeast and detection of rare breast cancer cells in blood, our method should also be amenable to other applications in which high...to UV light with a power of 8.0 mW/cm2 through the transparency mask for 90 seconds. The wafer was baked again at 95°C for 4 minutes then developed...separated from the replica and sonicated in isopropanol for 5 minutes, sonicated in deionized H2O for 5 minutes, and baked at 65°C for at least 30

  8. Determination of relative amounts of ribosome and subunits in Escherichia coli using asymmetrical flow field-flow fractionation.

    PubMed

    Nilsson, M; Birnbaum, S; Wahlund, K G

    1996-10-15

    The 30S and 50S subunits and the 70S ribosome of Escherichia coli were separated in 6 minutes by using asymmetrical flow field-flow fractionation (FFF). The total analysis time for determination of the relative amounts of ribosomes and free subunits in a preparation from a cell suspension was 8 min. The method can detect a change in the mass fraction of ribosomes if it exceeds approx, 10%. The separation is based on differences in diffusion coefficients, i.e., hydrodynamic diameters, and these can be determined from observed retention times. The hydrodynamic diameters were in good agreement with literature values obtained from electron microscopy. The mass fraction of ribosomes changed as a function of the magnesium ion concentration which confirms previous knowledge and shows the accuracy of the method. The method appears as an alternative to ultracentrifugation analysis and avoids some of its drawbacks and artefacts. An obvious application can be the optimisation of cell design in metabolic engineering in order to maximise translation and protein production.

  9. Quantification of NS1 dengue biomarker in serum via optomagnetic nanocluster detection

    NASA Astrophysics Data System (ADS)

    Antunes, Paula; Watterson, Daniel; Parmvi, Mattias; Burger, Robert; Boisen, Anja; Young, Paul; Cooper, Matthew A.; Hansen, Mikkel F.; Ranzoni, Andrea; Donolato, Marco

    2015-11-01

    Dengue is a tropical vector-borne disease without cure or vaccine that progressively spreads into regions with temperate climates. Diagnostic tools amenable to resource-limited settings would be highly valuable for epidemiologic control and containment during outbreaks. Here, we present a novel low-cost automated biosensing platform for detection of dengue fever biomarker NS1 and demonstrate it on NS1 spiked in human serum. Magnetic nanoparticles (MNPs) are coated with high-affinity monoclonal antibodies against NS1 via bio-orthogonal Cu-free ‘click’ chemistry on an anti-fouling surface molecular architecture. The presence of the target antigen NS1 triggers MNP agglutination and the formation of nanoclusters with rapid kinetics enhanced by external magnetic actuation. The amount and size of the nanoclusters correlate with the target concentration and can be quantified using an optomagnetic readout method. The resulting automated dengue fever assay takes just 8 minutes, requires 6 μL of serum sample and shows a limit of detection of 25 ng/mL with an upper detection range of 20000 ng/mL. The technology holds a great potential to be applied to NS1 detection in patient samples. As the assay is implemented on a low-cost microfluidic disc the platform is suited for further expansion to multiplexed detection of a wide panel of biomarkers.

  10. The Effect of Liquid Nitrogen on Bone Graft Survival.

    PubMed

    Sirinoglu, Hakan; Çilingir, Özlem Tuğçe; Çelebiler, Ozhan; Ercan, Feriha; Numanoglu, Ayhan

    2015-08-01

    Liquid nitrogen is used in medicine for cancer treatment and tissue preservation; however, bone viability after its application is controversial. This study aims to evaluate both the tissue viability and the clinical and histopathologic findings following liquid nitrogen application with different thawing techniques in rats. Mandibular bone grafts were taken from 45 Wistar rats and freezed in liquid nitrogen for 20 minutes. In the rapid-thawing technique (Rapid Thawing-1, Rapid Thawing-2), the grafts were held for 20 minutes in room temperature; in the slow-thawing technique (Slow Thawing-1, Slow Thawing-2), 20 minutes in -20°C, 20 minutes in +4°C, and 20 minutes in room temperature, respectively. In Rapid Thawing-2 and Slow Thawing-2 groups, autografts were implanted to their origin for 3 weeks and bone staining with India ink was performed and samples taken for histologic examination. The amount of cells and blood vessels and the density of bone canaliculi were significantly reduced in Rapid Thawing-1 and Slow Thawing-1 groups comparing to the Control group. However, the reduction rate was more significant in the Slow Thawing-1 group. Histomorphometric evaluation of the healing autografts after 3 weeks revealed that the decreased amounts of canaliculi were not changed in Slow Thawing-2 group. The study results demonstrated that bone tissue survives after liquid nitrogen treatment regardless of the performed thawing technique; however, slow thawing causes more tissue damage and metabolism impairment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Geology and ground-water resources of northern Mercer County, Pennsylvania

    USGS Publications Warehouse

    Schiner, G.R.; Kimmel, G.E.

    1976-01-01

    The Shenango and Stoneboro 15-minute quadrangles are in northwestern Pennsylvania and are about 60 miles north of Pitts burgh. These two quadrangles comprise the following 7%-minute quadrangles: Greenville West, Greenville East, Sharpsville, Fredonia, Hadley, New Lebanon, Jackson Center, and Sandy Lake. The area covered by the two quadrangles includes the northern two thirds of Mercer County and a small amount of adjoining southern Crawford County.

  12. Physical activity during pregnancy: impact of applying different physical activity guidelines.

    PubMed

    Smith, Katie M; Campbell, Christina G

    2013-01-01

    Multiple guidelines and definitions of physical activity (PA) have been used to study the benefits of activity during pregnancy. The different guidelines lead to a wide range of prevalence estimates and this has led to conflicting reports about activity patterns during pregnancy. A longitudinal study was conducted to assess PA using a pattern-recognition monitor for a 7-day period at week 18 (n = 55) and week 35 (n = 66) of pregnancy. The amount of activity performed and the number of women meeting six different PA guidelines were evaluated. Adherence to PA guidelines ranged from 5 to 100% and 9 to 100% at weeks 18 and 35, respectively. All women achieved the 500 MET-minute guideline and nearly all women accumulated ≥150 minutes of weekly moderate-vigorous physical activity (MVPA) at both time points. Only 22% and 26% participated in ≥3 sessions of MVPA lasting ≥30 minutes at both time points and this further declined to 5% and 9% when the guideline was increased to ≥5 sessions of 30 minutes. The amount of PA during pregnancy varied drastically depending on which guideline was used. Further research is warranted to clearly identify the patterns of activity that are associated with healthy pregnancy outcomes.

  13. Physical Activity during Pregnancy: Impact of Applying Different Physical Activity Guidelines

    PubMed Central

    Smith, Katie M.; Campbell, Christina G.

    2013-01-01

    Multiple guidelines and definitions of physical activity (PA) have been used to study the benefits of activity during pregnancy. The different guidelines lead to a wide range of prevalence estimates and this has led to conflicting reports about activity patterns during pregnancy. A longitudinal study was conducted to assess PA using a pattern-recognition monitor for a 7-day period at week 18 (n = 55) and week 35 (n = 66) of pregnancy. The amount of activity performed and the number of women meeting six different PA guidelines were evaluated. Adherence to PA guidelines ranged from 5 to 100% and 9 to 100% at weeks 18 and 35, respectively. All women achieved the 500 MET-minute guideline and nearly all women accumulated ≥150 minutes of weekly moderate-vigorous physical activity (MVPA) at both time points. Only 22% and 26% participated in ≥3 sessions of MVPA lasting ≥30 minutes at both time points and this further declined to 5% and 9% when the guideline was increased to ≥5 sessions of 30 minutes. The amount of PA during pregnancy varied drastically depending on which guideline was used. Further research is warranted to clearly identify the patterns of activity that are associated with healthy pregnancy outcomes. PMID:23476778

  14. Methods of Advanced Wound Management for Care of Combined Traumatic and Chemical Warfare Injuries

    PubMed Central

    Graham, John S.; Gerlach, Travis W.; Logan, Thomas P.; Bonar, James P.; Fugo, Richard J.; Lee, Robyn B.; Coatsworth, Matthew A.

    2008-01-01

    Objective: Chemical warfare agents are potential threats to military personnel and civilians. The potential for associated traumatic injuries is significant. Damage control surgery could expose medical personnel to agents contaminating the wounds. The objectives of this study were to demonstrate efficacy of surgical decontamination and assess exposure risk to attending personnel. Methods: Weanling pigs were randomly assigned to 2 of 4 debridement tools (scalpel, Bovie® knife, Fugo Blade®, and Versajet™ Hydrosurgery System). Penetrating traumatic wounds were created over the shoulder and thigh and then exposed to liquid sulfur mustard (HD) for 60 minutes. Excisional debridement of the injuries was performed while vapors over each site were collected. Gas chromatography was used to measure HD in samples of collected vapors. Unbound HD was quantified in presurgical wound swabs, excised tissues, and peripheral tissue biopsies following solvent extraction. Results: Excisional debridement produced agent-free wound beds (surgical decontamination). A significant amount of HD vapor was detected above the surgical fields with each tool. Apart from the Versajet™ producing significantly lower levels of HD detected over thigh wounds compared with those treated using the scalpel, there were no differences in the amount of agent detected among the tools. All measured levels significantly exceeded established safety limits. Vesicating levels of unbound HD were extracted from excised tissue. There was no measured lateral spreading of HD beyond the surgical margins. Conclusions: There is significant occupational exposure risk to HD during surgical procedures designed to stabilize agent-contaminated wounds. If appropriate protective measures are taken, surgical decontamination is both effective and safe. PMID:18716652

  15. Fast cadence planet-searches with the all-sky, gigapixel-scale Evryscope

    NASA Astrophysics Data System (ADS)

    Ratzloff, Jeff; Law, Nicholas

    2018-01-01

    The Evryscope is a 24-camera robotic telescope that continuously images 8,000 square degrees in 2-minute exposures, that has been collecting data continuously since deployment to CTIO in mid-2015. The telescope provides the fast cadence observations necessary for detecting minute to tens-of-minute time-scale exoplanet transits, which would occur around small, compact host stars including White Dwarfs and Hot Subdwarfs. We are conducting target surveys for each of these types of stars searching for potential planet transit signals. Our surveys will be the largest performed to date with several thousand targets in each group and years of observations, and the only surveys with minute-scale cadence. We present the status of the surveys, our estimated detection ability, interesting candidates, and preliminary results.

  16. The Relationship between Time in Computer-Assisted Instruction and the Increase in Reading Skills

    ERIC Educational Resources Information Center

    Shannon, Rene M.

    2013-01-01

    Educational leadership appropriates significant amounts of money for technology in school budgets. Teachers must decide how to use technology to maximize student learning and make the most efficient use of instructional minutes. The purpose of this quantitative correlational study was to determine if a relationship existed between the amount of…

  17. Correlation between CO2 storage at the last minute of gas insufflation and area of retroperitoneal lacuna during retroperitoneal laparoscopic radical nephrectomy.

    PubMed

    Hu, Jian-Jun; Liu, Ya-Hua; Yu, Chan-Juan; Jialielihan, Nuerbolati

    2016-07-22

    Adequate operation interspace is the premise of laparoscopy, and carbon dioxide (CO2) was an ideal gas for forming lacuna. A retroperitoneal space is used to form operation interspace in retroperitoneal laparoscopic radical nephrectomy by making ballooning, and the retroperitoneal space has no relative complete and airtight serous membrane, therefore CO2 absorption may be greater in retroperitoneal than transperitoneal laparoscopic radical nephrectomy. Excess CO2 absorption may induce hypercapnemia and further cause physiopathological change of respiratory and circulatory system. Therefore, exact evaluation of amount of CO2 which is eliminated from body via minute ventilation is important during retroperitoneal laparoscopic radical nephrectomy. The aim of the paper is to study the correlation between CO2 storage at the last minute of gas insufflation and area of retroperitoneal lacuna during retroperitoneal laparoscopic radical nephrectomy. Forty ASA I/II patients undergoing retroperitoneal laparoscopic radical nephrectomy were enrolled. CO2 storage at the last minute of gas insufflation and area of a retroperitoneal lacuna were observed. Linear correlation and regression were performed to determine the correlation between them. There was positive correlation between CO2 storage at the last minute of gas insufflation and area of retroperitoneal lacuna (r = 0.880, P = 0.000), and the equation of linear regression was y = -83.097 + 0.925x (R(2) = 0.780, t = 11.610, P = 0.000). Amount of CO2 which is eliminated from body via mechanical ventilation could be calculated by measuring the area of retroperitoneal lacuna during retroperitoneal laparoscopic radical nephrectomy, and an anesthetist should be aware of the size of lacuna to predict high CO2 storage at the last minute of gas insufflation.

  18. Aspects of Tactical Biological Defense

    DTIC Science & Technology

    1994-06-03

    physical proof of Soviet emplcyment of mycotoxins in those countries had been obtained. 30 Biochemical casualties in Laos, Kampuchea and Afghanistan...detection capability. The current system planned for use is the XM-21 Remote Sensing Chemical Agent Alarm (RSCAAL). It uses infrared sensors to detect...Micrometer(s). min. Minute(s). MS. Mans spectroscopy /mass spectrometer. NBC, Nuclear, biological and chemical. pfu. Plaque forming units--the number of

  19. Lubiprostone decreases the small bowel transit time by capsule endoscopy: an exploratory, randomised, double-blind, placebo-controlled 3-way crossover study.

    PubMed

    Matsuura, Mizue; Inamori, Masahiko; Endo, Hiroki; Matsuura, Tetsuya; Kanoshima, Kenji; Inoh, Yumi; Fujita, Yuji; Umezawa, Shotaro; Fuyuki, Akiko; Uchiyama, Shiori; Higurashi, Takuma; Ohkubo, Hidenori; Sakai, Eiji; Iida, Hiroshi; Nonaka, Takashi; Futagami, Seiji; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi

    2014-01-01

    The aim of this study was to investigate the usefulness of lubiprostone for bowel preparation and as a propulsive agent in small bowel endoscopy. Six healthy male volunteers participated in this randomized, 3-way crossover study. The subjects received a 24 μg tablet of lubiprostone 60 minutes prior to the capsule ingestion for capsule endoscopy (CE) and a placebo tablet 30 minutes before the capsule ingestion (L-P regimen), a placebo tablet 60 minutes prior to CE and a 24 μg tablet of lubiprostone 30 minutes prior to CE (P-L regimen), or a placebo tablet 60 minutes prior to r CE and a placebo tablet again 30 minutes prior to CE (P-P regimen). The quality of the capsule endoscopic images and the amount of water in the small bowel were assessed on 5-point scale. The median SBTT was 178.5 (117-407) minutes in the P-P regimen, 122.5 (27-282) minutes in the L-P regimen, and 110.5 (11-331) minutes in the P-L regimen (P = 0.042). This study showed that the use of lubiprostone significantly decreased the SBTT. We also confirmed that lubiprostone was effective for inducing water secretion into the small bowel during CE.

  20. Automated identification of retained surgical items in radiological images

    NASA Astrophysics Data System (ADS)

    Agam, Gady; Gan, Lin; Moric, Mario; Gluncic, Vicko

    2015-03-01

    Retained surgical items (RSIs) in patients is a major operating room (OR) patient safety concern. An RSI is any surgical tool, sponge, needle or other item inadvertently left in a patients body during the course of surgery. If left undetected, RSIs may lead to serious negative health consequences such as sepsis, internal bleeding, and even death. To help physicians efficiently and effectively detect RSIs, we are developing computer-aided detection (CADe) software for X-ray (XR) image analysis, utilizing large amounts of currently available image data to produce a clinically effective RSI detection system. Physician analysis of XRs for the purpose of RSI detection is a relatively lengthy process that may take up to 45 minutes to complete. It is also error prone due to the relatively low acuity of the human eye for RSIs in XR images. The system we are developing is based on computer vision and machine learning algorithms. We address the problem of low incidence by proposing synthesis algorithms. The CADe software we are developing may be integrated into a picture archiving and communication system (PACS), be implemented as a stand-alone software application, or be integrated into portable XR machine software through application programming interfaces. Preliminary experimental results on actual XR images demonstrate the effectiveness of the proposed approach.

  1. Preliminary Assessment/Site Inspection Health and Safety Plan, Granite Mountain RRS, Alaska

    DTIC Science & Technology

    1994-08-01

    pain. apple cores. banana peels , lettuce, fish and game carcasses, etc.). Sealed beafproof contuiner: a container sealed to prevent the escap...acrylates, and alcohols . These substances are slightly to highly volatile and are moderately to highly flammable. Primary routes of entry into the body...with copious amounts of water for at least 15 minutes. Get emergency medical assistance. 3 Skin Contact: Flush thoroughly for at least 1S minutes& Wash

  2. Developing a Digital Medicine System in Psychiatry: Ingestion Detection Rate and Latency Period.

    PubMed

    Profit, Deborah; Rohatagi, Shashank; Zhao, Cathy; Hatch, Ainslie; Docherty, John P; Peters-Strickland, Timothy S

    2016-09-01

    A digital medicine system (DMS) has been developed to measure and report adherence to an atypical antipsychotic, aripiprazole, in psychiatric patients. The DMS consists of 3 components: ingestible sensor embedded in a medication tablet, wearable sensor, and secure mobile and cloud-based applications. An umbrella study protocol was designed to rapidly assess the technical performance and safety of the DMS in multiple substudies to guide the technology development. Two sequential substudies enrolled 30 and 29 healthy volunteers between March-April 2014 and February-March 2015, respectively, to assess detection accuracy of the ingestible sensor by the DMS and the latency period between ingestion and detection of the ingestion by the wearable sensor or the cloud-based server. The first substudy identified areas for improvement using early versions of the wearable sensor and the mobile application. The second substudy tested updated versions of the components and showed an overall ingestion detection rate of 96.6%. Mean latency times for the signal transmission were 1.1-1.3 minutes (from ingestion to the wearable sensor detection) and 6.2-10.3 minutes (from the wearable sensor detection to the server detection). Half of transmissions were completed in < 2 minutes, and ~90% of ingestions were registered by the smartphone within 30 minutes of ingestion. No serious adverse events, discontinuations, or clinically significant laboratory/vital signs findings were reported. The DMS implementing modified versions of the smartphone application and the wearable sensor has the technical capability to detect and report tablet ingestion with high accuracy and acceptable latency time. ClinicalTrials.gov identifier: NCT02091882. © Copyright 2016 Physicians Postgraduate Press, Inc.

  3. PCR in laboratory diagnosis of human Borrelia burgdorferi infections.

    PubMed

    Schmidt, B L

    1997-01-01

    The laboratory diagnosis of Lyme borreliosis, the most prevalent vector-borne disease in the United States and endemic in parts of Europe and Asia, is currently based on serology with known limitations. Direct demonstration of Borrelia burgdorferi by culture may require weeks, while enzyme-linked immunosorbent assays for antigen detection often lack sensitivity. The development of the PCR has offered a new dimension in the diagnosis. Capable of amplifying minute amounts of DNA into billions of copies in just a few hours, PCR facilitates the sensitive and specific detection of DNA or RNA of pathogenic organisms. This review is restricted to applications of PCR methods in the diagnosis of human B. burgdorferi infections. In the first section, methodological aspects, e.g., sample preparation, target selection, primers and PCR methods, and detection and control of inhibition and contamination, are highlighted. In the second part, emphasis is placed on diagnostic aspects, where PCR results in patients with dermatological, neurological, joint, and ocular manifestations of the disease are discussed. Here, special attention is given to monitoring treatment efficacy by PCR tests. Last, specific guidelines on how to interpret PCR results, together with the advantages and limitations of these new techniques, are presented.

  4. Super-Nyquist White Dwarf Pulsations in K2 Long-Cadence Data

    NASA Astrophysics Data System (ADS)

    Bell, Keaton J.; Hermes, JJ; Montgomery, Michael H.; Vanderbosch, Zach

    2017-06-01

    The Kepler and K2 missions have recently revolutionized the field of white dwarf asteroseismology. Since white dwarfs pulsate on timescales of order 10 minutes, we aim to observe these objects at K2’s short cadence (1 minute). Occasionally we find signatures of pulsations in white dwarf targets that were only observed by K2 at long cadence (30 minute). These signals suffer extreme aliasing since the intrinsic frequencies exceed the Nyquist sampling limit. We present our work to recover accurate frequency determinations for these targets, guided by a limited amount of supplementary, ground-based photometry from McDonald Observatory.

  5. Data Compression Algorithm Architecture for Large Depth-of-Field Particle Image Velocimeters

    NASA Technical Reports Server (NTRS)

    Bos, Brent; Memarsadeghi, Nargess; Kizhner, Semion; Antonille, Scott

    2013-01-01

    A large depth-of-field particle image velocimeter (PIV) is designed to characterize dynamic dust environments on planetary surfaces. This instrument detects lofted dust particles, and senses the number of particles per unit volume, measuring their sizes, velocities (both speed and direction), and shape factors when the particles are large. To measure these particle characteristics in-flight, the instrument gathers two-dimensional image data at a high frame rate, typically >4,000 Hz, generating large amounts of data for every second of operation, approximately 6 GB/s. To characterize a planetary dust environment that is dynamic, the instrument would have to operate for at least several minutes during an observation period, easily producing more than a terabyte of data per observation. Given current technology, this amount of data would be very difficult to store onboard a spacecraft, and downlink to Earth. Since 2007, innovators have been developing an autonomous image analysis algorithm architecture for the PIV instrument to greatly reduce the amount of data that it has to store and downlink. The algorithm analyzes PIV images and automatically reduces the image information down to only the particle measurement data that is of interest, reducing the amount of data that is handled by more than 10(exp 3). The state of development for this innovation is now fairly mature, with a functional algorithm architecture, along with several key pieces of algorithm logic, that has been proven through field test data acquired with a proof-of-concept PIV instrument.

  6. Differences in sedentary time and physical activity between female patients with fibromyalgia and healthy controls: the al-Ándalus project.

    PubMed

    Segura-Jiménez, Víctor; Álvarez-Gallardo, Inmaculada C; Estévez-López, Fernando; Soriano-Maldonado, Alberto; Delgado-Fernández, Manuel; Ortega, Francisco B; Aparicio, Virginia A; Carbonell-Baeza, Ana; Mota, Jorge; Silva, Pedro; Ruiz, Jonatan R

    2015-11-01

    To characterize the levels of objectively measured time spent in sedentary activities (sedentary time) and physical activities in female patients with fibromyalgia and compare them with the levels in age-matched healthy control women. The study comprised 413 female patients with fibromyalgia (mean ± SD age 51.9 ± 7.4 years) and 188 female control subjects (age 50.9 ± 7.5 years). Sedentary time, the amount of time spent engaged in physical activity, and step counts were measured using triaxial accelerometry. The amounts of time (minutes/day) during which the participants were engaged in sedentary behaviors as well as in physical activity of different intensities (light, moderate, and moderate-to-vigorous) and the step counts were calculated. The amount of time spent in sedentary behavior was longer in patients with fibromyalgia compared with controls (estimated mean ± SEM difference 39 ± 8 minutes/day; P < 0.001). The patients with fibromyalgia spent less time than controls engaged in light physical activity (mean ± SEM difference -21 ± 7 minutes/day; P = 0.005), moderate physical activity (mean ± SEM difference -17 ± 3 minutes/day; P < 0.001), and moderate-to-vigorous physical activity (mean ± SEM difference -19 ± 3 minutes/day; P < 0.001). The patients with fibromyalgia took fewer steps/day compared with the control subjects (mean ± SEM difference -1,881 ± 262 steps/day; P < 0.001). Only 20.6% of the patients with fibromyalgia and 46.3% of the control subjects fulfilled the recommendation for 150 minutes/week of moderate-to-vigorous physical activity in bouts of at least 10 minutes/bout (χ(2)  = 41.8, P < 0.001). Similarly, only 16.0% of the patients fulfilled the recommendation for ≥10,000 steps/day compared with 44.7% of the control subjects (χ(2)  = 56.8, P < 0.001). Both the patients and the control subjects were more active (physical activity of all intensities and numbers of steps) on weekdays than on weekend days (all P ≤ 0.001). Female patients with fibromyalgia spent more time in sedentary behaviors and were less physically active than age-matched controls. The low proportions of female patients with fibromyalgia and control subjects who met the physical activity and step count recommendations is worrisome. © 2015, American College of Rheumatology.

  7. Comparison of perioperative outcomes between endoscope-assisted technique and handheld acoustic Doppler for perforator identification in fasciocutaneous flaps.

    PubMed

    Huang, Jen-Wu; Huang, Chih-Sheng; Shih, Yu-Chung; Perng, Cherng-Kang; Lin, Yi-Ying; Wu, Szu-Hsien

    2018-06-01

    The endoscopic technique has been utilized to harvest muscle flaps and detect perforators of fasciocutaneous flaps. This study aimed to compare the perioperative outcomes between the endoscope-assisted technique and handheld acoustic Doppler for perforator identification in fasciocutaneous flaps.This retrospective case-control study included patients who underwent fasciocutaneous flap reconstruction for traumatic soft tissue defects. In the case group, perforator identification was assisted by the endoscope-assisted technique. In the control group, age- and sex-matched patients received handheld acoustic Doppler to detect perforators. Perioperative outcomes, flap characteristics, and postoperative complications were compared.There were 12 patients in the case group and 12 in the control group. Compared with the control group, the case group had a significantly shorter length of donor-site wounds (9 cm vs 12 cm, P = .023) and a significantly smaller proportion of patients receiving skin grafting at the donor sites (0% vs 41.7%, P = .037). The case group had a longer operative time, but the difference was not statistically significant (180 minutes vs 150 minutes, P = .367). The amount of blood loss, the time length of postoperative drainage, and complications did not significantly differ between the 2 groups.The endoscope-assisted technique for perforator identification of fasciocutaneous flaps provided less donor-site morbidity and a significantly shorter length of donor-site wounds than the conventional handheld acoustic Doppler, which suggests that this technique could be a valuable alternative when a precise design is indicated.

  8. Economic evaluation of orthoptic screening: results of a field study in 121 German kindergartens.

    PubMed

    König, Hans-Helmut; Barry, Jean-Cyriaque; Leidl, Reiner; Zrenner, Eberhart

    2002-10-01

    The purpose of this study was to analyze the cost-effectiveness of an orthoptic screening program in kindergarten children. An empiric cost-effectiveness analysis was conducted as part of a field study of orthoptic screening. Three-year-old children (n = 1180) in 121 German kindergartens were screened by orthoptists. The number of newly diagnosed cases of amblyopia and amblyogenic factors (target conditions) was used as the measure of effectiveness. The direct costs of orthoptic screening were calculated from a third-party-payer perspective based on comprehensive measurement of working hours and material costs. The average cost of a single orthoptic screening examination was 12.58 Euro. This amount consisted of labor costs (10.99 Euro) and costs of materials and traveling (1.60 Euro). With 9.9 children screened on average per kindergarten, average labor time was 279 minutes per kindergarten, or 28 minutes per child. It consisted of time for organization (46%), traveling (16%), preparing the examination site (10%), and the orthoptic examination itself (28%). The total cost of the screening program in all 121 kindergartens (including ophthalmic examination, if required) was 21,253 Euro. Twenty-three new cases of the target conditions were detected. The cost-effectiveness ratio was 924 Euro per detected case. Sensitivity analysis showed that the prevalence and the specificity of orthoptic screening had substantial influence on the cost-effectiveness ratio. The data on the cost-effectiveness of orthoptic screening in kindergarten may be used by such third-party payers as health insurance or public health services when deciding about organizing and financing preschool vision-screening programs.

  9. A method for the rapid detection of urinary tract infections.

    PubMed

    Olsson, Carl; Kapoor, Deepak; Howard, Glenn

    2012-04-01

    To determine the reliability of a rapid detection method compared with the reference standard streaked agar plate in diagnosing the presence of urinary tract infection (UTI). De-identified clean catch urine specimens from 980 office visit patients were processed during a 30-day period. Classic 1-μL and 10-μL streaked agar plates were used in parallel with the new CultureStat Rapid UTI Detection System (CSRUDS). Urine results were evaluated using the CSRUDS at 30 and 90 minutes after collection. A comparative analysis of the subsequent plate results versus the CSRUDS results was achieved for 973 of these samples. Positive UTI conditions were accurately identified by both CSRUDS and agar streak plate methods. CSRUDS accurately identified UTI negative conditions with 99.3% reliability at 90 minutes. The negative predictive value of CSRUDS was 99.2% at 30 minutes. Current agar plating for first-round UTI screening has substantial documented problems that can negatively affect an accurate and timely UTI diagnosis. A novel rapid detection system, the CSRUDS provides UTI negative/positive same-day results in ≤ 90 minutes from the start of test. Such rapidly available results will enable more accurate and timely clinical decisions to be made in the urology office, particularly regarding infection status before urologic instrumentation. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Photoprotection by sunscreen depends on time spent on application.

    PubMed

    Heerfordt, Ida M; Torsnes, Linnea R; Philipsen, Peter A; Wulf, Hans Christian

    2018-03-01

    To be effective, sunscreens must be applied in a sufficient quantity and reapplication is recommended. No previous study has investigated whether time spent on sunscreen application is important for the achieved photoprotection. To determine whether time spent on sunscreen application is related to the amount of sunscreen used during a first and second application. Thirty-one volunteers wearing swimwear applied sunscreen twice in a laboratory environment. Time spent and the amount of sunscreen used during each application was measured. Subjects' body surface area accessible for sunscreen application (BSA) was estimated from their height, weight and swimwear worn. The average applied quantity of sunscreen after each application was calculated. Subjects spent on average 4 minutes and 15 seconds on the first application and approximately 85% of that time on the second application. There was a linear relationship between time spent on application and amount of sunscreen used during both the first and the second application (P < .0001). Participants applied 2.21 grams of sunscreen per minute during both applications. After the first application, subjects had applied a mean quantity of sunscreen of 0.71 mg/cm 2 on the BSA, and after the second application, a mean total quantity of 1.27 mg/cm 2 had been applied. We found that participants applied a constant amount of sunscreen per minute during both a first and a second application. Measurement of time spent on application of sunscreen on different body sites may be useful in investigating the distribution of sunscreen in real-life settings. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. An Extraordinary Outburst of the Magnetar Swift J1822.3-1606

    NASA Astrophysics Data System (ADS)

    Chakraborty, Manoneeta; Göğüş, Ersin

    2015-08-01

    The 2011 outburst of Swift J1822.3-1606 was extraordinary; periodic modulations at the spin period of the underlying neutron star were clearly visible, remarkably similar to what is observed during the decaying tail of magnetar giant flares. We investigated the temporal characteristics of X-ray emission during the early phases of the outburst. We performed a periodicity search with the spectral hardness ratio (HR) and found a coherent signal near the spin period of the neutron star, but with a lag of about 3 radians. Therefore, the HR is strongly anti-correlated with the X-ray intensity, which is also seen in the giant flares. We studied the time evolution of the pulse profile and found that it evolves from a complex morphology to a much simpler shape within about a month. Pulse profile simplification also takes place during the giant flares, but on a much shorter timescale of about a few minutes. We found that the amount of energy emitted during the first 25 days of the outburst is comparable to what was detected in minutes during the decaying tail of giant flares. Based on these similarities, we suggest that the triggering mechanisms of the giant flares and the magnetar outbursts are likely the same. We propose that the trapped fireball that develops in the magnetosphere at the onset of the outburst radiates away efficiently in minutes in magnetars exhibiting giant flares, while in other magnetars, such as Swift J1822.3-1606, the efficiency of radiation of the fireball is not as high and, therefore, lasts much longer.

  12. CT-guided sternoclavicular joint injections: description of the procedure, reliability of imaging diagnosis, and short-term patient responses.

    PubMed

    Peterson, Cynthia K; Saupe, Nadja; Buck, Florian; Pfirrmann, Christian W A; Zanetti, Marco; Hodler, Juerg

    2010-12-01

    The purpose of this study was to evaluate pain relief 20 to 30 minutes after diagnostic or therapeutic injections into the sternoclavicular joint and to compare patient outcomes based on the CT diagnosis. Informed consent was obtained from each patient. Ethics approval was not required. Fifty patients who had CT-guided injections of corticosteroid and local anesthetic into their sternoclavicular joints were included in the study. Preinjection and 20- to 30-minute postinjection visual analog scale data were recorded and compared with the imaging findings agreed by consensus. Kappa statistics were calculated for the reliability of imaging diagnosis. The percentage of patients improving after joint injection was calculated, and the risk ratio comparing the response of patients with osteoarthritis to those without osteoarthritis was completed. The correlation between the severity of each patient's osteoarthritis and the pain response was calculated using Spearman's correlation coefficient. Sixty-six percent of the patients reported clinically significant pain reduction at between 20 and 30 minutes after injection. The proportion of patients with osteoarthritis who had a clinically significant response was 67% compared with 64% for patients who did not have osteoarthritis. This difference was not statistically or clinically significant. There was no correlation between the severity of osteoarthritis and the amount of pain reduction (r = 0.03). The reliability of imaging diagnosis was substantial. Two thirds of patients having sternoclavicular joint injections of corticosteroids and local anesthetics report clinically significant improvement regardless of the abnormalities detected on their CT images.

  13. DNA typing in forensic medicine and in criminal investigations: a current survey.

    PubMed

    Benecke, M

    1997-05-01

    Since 1985 DNA typing of biological material has become one of the most powerful tools for personal identification in forensic medicine and in criminal investigations [1-6]. Classical DNA "fingerprinting" is increasingly being replaced by polymerase chain reaction (PCR) based technology which detects very short polymorphic stretches of DNA [7-15]. DNA loci which forensic scientists study do not code for proteins, and they are spread over the whole genome [16, 17]. These loci are neutral, and few provide any information about individuals except for their identity. Minute amounts of biological material are sufficient for DNA typing. Many European countries are beginning to establish databases to store DNA profiles of crime scenes and known offenders. A brief overview is given of past and present DNA typing and the establishment of forensic DNA databases in Europe.

  14. DNA typing in forensic medicine and in criminal investigations: a current survey

    NASA Astrophysics Data System (ADS)

    Benecke, Mark

    Since 1985 DNA typing of biological material has become one of the most powerful tools for personal identification in forensic medicine and in criminal investigations [1-6]. Classical DNA "fingerprinting" is increasingly being replaced by polymerase chain reaction (PCR) based technology which detects very short polymorphic stretches of DNA [7-15]. DNA loci which forensic scientists study do not code for proteins, and they are spread over the whole genome [16, 17]. These loci are neutral, and few provide any information about individuals except for their identity. Minute amounts of biological material are sufficient for DNA typing. Many European countries are beginning to establish databases to store DNA profiles of crime scenes and known offenders. A brief overview is given of past and present DNA typing and the establishment of forensic DNA databases in Europe.

  15. Portable X-Ray, K-Edge Heavy Metal Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fricke, V.

    The X-Ray, K-Edge Heavy Metal Detection System was designed and built by Ames Laboratory and the Center for Nondestructive Evaluation at Iowa State University. The system uses a C-frame inspection head with an X-ray tube mounted on one side of the frame and an imaging unit and a high purity germanium detector on the other side. the inspection head is portable and can be easily positioned around ventilation ducts and pipes up to 36 inches in diameter. Wide angle and narrow beam X-ray shots are used to identify the type of holdup material and the amount of the contaminant. Precisemore » assay data can be obtained within minutes of the interrogation. A profile of the containerized holdup material and a permanent record of the measurement are immediately available.« less

  16. Adaptive motion artifact reducing algorithm for wrist photoplethysmography application

    NASA Astrophysics Data System (ADS)

    Zhao, Jingwei; Wang, Guijin; Shi, Chenbo

    2016-04-01

    Photoplethysmography (PPG) technology is widely used in wearable heart pulse rate monitoring. It might reveal the potential risks of heart condition and cardiopulmonary function by detecting the cardiac rhythms in physical exercise. However the quality of wrist photoelectric signal is very sensitive to motion artifact since the thicker tissues and the fewer amount of capillaries. Therefore, motion artifact is the major factor that impede the heart rate measurement in the high intensity exercising. One accelerometer and three channels of light with different wavelengths are used in this research to analyze the coupled form of motion artifact. A novel approach is proposed to separate the pulse signal from motion artifact by exploiting their mixing ratio in different optical paths. There are four major steps of our method: preprocessing, motion artifact estimation, adaptive filtering and heart rate calculation. Five healthy young men are participated in the experiment. The speeder in the treadmill is configured as 12km/h, and all subjects would run for 3-10 minutes by swinging the arms naturally. The final result is compared with chest strap. The average of mean square error (MSE) is less than 3 beats per minute (BPM/min). Proposed method performed well in intense physical exercise and shows the great robustness to individuals with different running style and posture.

  17. Dielectrophoresis enhances the whitening effect of carbamide peroxide on enamel.

    PubMed

    Ivanoff, Chris S; Hottel, Timothy L; Garcia-Godoy, Franklin; Riga, Alan T

    2011-10-01

    To compare the enamel whitening effect of a 20-minute dielectrophoresis enhanced electrochemical delivery to a 20-minute diffusion treatment. Forty freshly extracted human teeth without detectable caries or restoration were stored in distilled water at 4 degrees C and used within 1 month of extraction. Two different bleaching gels (Plus White 5 Minute Speed Whitening Gel and 35% Opalescence PF gel) were tested. The study had two parts: Part 1--Quantitative comparison of hydrogen peroxide (H2O2, HP) absorption--following application of an over-the-counter 35% HP whitening gel (Plus White 5 Minute Speed Whitening Gel) to 30 (n = 30) extracted human teeth by conventional diffusion or dielectrophoresis. The amount of H2O2 that diffused from the dentin was measured by a colorimetric oxidation-reduction reaction kit. HP concentration was measured by UV-Vis spectroscopy at 550 nm. Part 2--HP diffusion in stained teeth--35% carbamide peroxide whitening gel (35% Opalescence PF gel) was applied to 10 extracted human teeth (n = 10) stained by immersion in a black tea solution for 48 hours. The teeth were randomly assigned to the 20-minute dielectrophoresis or diffusion treatment group; whitening was evaluated by a dental spectrophotometer and macro-photography. Part 1: The analysis found significant differences between both groups with relative percent errors of 3% or less (a single outlier had an RPE of 12%). The average absorbance for the dielectrophoresis group in round 1 was 79% greater than the diffusion group. The average absorbance for the dielectrophoresis group in round 2 was 130% greater than the diffusion group. A single-factor ANOVA found a statistically significant difference between the diffusion and dielectrophoresis groups (P = 0.01). Part 2--The average change in Shade Guide Units (SGU) was 0.6 for the diffusion group, well under the error of measurement of 0.82 SGU. The average change in SGU for the dielectrophoresis group was 9, significantly above the error of measurement and 14 times or 1,400% greater than the diffusion group average. A single-factor ANOVA found a statistically significant difference between the diffusion and dielectrophoresis treatment groups (P < 0.001).

  18. Rapid detection of acetamiprid in foods using surface-enhanced Raman spectroscopy (SERS).

    PubMed

    Wijaya, Wisiani; Pang, Shintaro; Labuza, Theodore P; He, Lili

    2014-04-01

    Acetamiprid is a neonicotinoid pesticide that is commonly used in modern farming. Acetamiprid residue in food commodities can be a potential harm to human and has been implicated in the honey bee hive die off crisis. In this study, we developed rapid, simple, and sensitive methods to detect acetamiprid in apple juice and on apple surfaces using surface-enhanced Raman spectroscopy (SERS). No pretreatment of apple juice sample was performed. A simple surface swab method was used to recover acetamiprid from the apple surface. Samples were incubated with silver dendrites for several minutes and SERS spectra were taken directly from the silver surface. Detection of a set of 5 apple juice samples can be done within 10 min. The swab-SERS method took 15 min for a set of 5 samples. Resulting spectral data were analyzed using principal component analysis. The highest acetamiprid peak at 634 cm(-1) was used to detect and quantify the amount of acetamiprid spiked in 1:1 water-methanol solvent, apple juice, and on apple surface. The SERS method was able to successfully detect acetamiprid at 0.5 μg/mL (0.5 ppm) in solvent, 3 μg/mL (3 ppm) in apple juice, and 0.125 μg/cm(2) on apple surfaces. The SERS methods provide simple, rapid, and sensitive ways to detect acetamiprid in beverages and on the surfaces of thick skinned fruits and vegetables. © 2014 Institute of Food Technologists®

  19. Integrating Flexible Sensor and Virtual Self-Organizing DC Grid Model With Cloud Computing for Blood Leakage Detection During Hemodialysis.

    PubMed

    Huang, Ping-Tzan; Jong, Tai-Lang; Li, Chien-Ming; Chen, Wei-Ling; Lin, Chia-Hung

    2017-08-01

    Blood leakage and blood loss are serious complications during hemodialysis. From the hemodialysis survey reports, these life-threatening events occur to attract nephrology nurses and patients themselves. When the venous needle and blood line are disconnected, it takes only a few minutes for an adult patient to lose over 40% of his / her blood, which is a sufficient amount of blood loss to cause the patient to die. Therefore, we propose integrating a flexible sensor and self-organizing algorithm to design a cloud computing-based warning device for blood leakage detection. The flexible sensor is fabricated via a screen-printing technique using metallic materials on a soft substrate in an array configuration. The self-organizing algorithm constructs a virtual direct current grid-based alarm unit in an embedded system. This warning device is employed to identify blood leakage levels via a wireless network and cloud computing. It has been validated experimentally, and the experimental results suggest specifications for its commercial designs. The proposed model can also be implemented in an embedded system.

  20. A comparison of continuous video-EEG monitoring and 30-minute EEG in an ICU.

    PubMed

    Khan, Omar I; Azevedo, Christina J; Hartshorn, Alendia L; Montanye, Justin T; Gonzalez, Juan C; Natola, Mark A; Surgenor, Stephen D; Morse, Richard P; Nordgren, Richard E; Bujarski, Krzysztof A; Holmes, Gregory L; Jobst, Barbara C; Scott, Rod C; Thadani, Vijay M

    2014-12-01

    To determine whether there is added benefit in detecting electrographic abnormalities from 16-24 hours of continuous video-EEG in adult medical/surgical ICU patients, compared to a 30-minute EEG. This was a prospectively enroled non-randomized study of 130 consecutive ICU patients for whom EEG was requested. For 117 patients, a 30-minute EEG was requested for altered mental state and/or suspected seizures; 83 patients continued with continuous video-EEG for 16-24 hours and 34 patients had only the 30-minute EEG. For 13 patients with prior seizures, continuous video-EEG was requested and was carried out for 16-24 hours. We gathered EEG data prospectively, and reviewed the medical records retrospectively to assess the impact of continuous video-EEG. A total of 83 continuous video-EEG recordings were performed for 16-24 hours beyond 30 minutes of routine EEG. All were slow, and 34% showed epileptiform findings in the first 30 minutes, including 2% with seizures. Over 16-24 hours, 14% developed new or additional epileptiform abnormalities, including 6% with seizures. In 8%, treatment was changed based on continuous video-EEG. Among the 34 EEGs limited to 30 minutes, almost all were slow and 18% showed epileptiform activity, including 3% with seizures. Among the 13 patients with known seizures, continuous video-EEG was slow in all and 69% had epileptiform abnormalities in the first 30 minutes, including 31% with seizures. An additional 8% developed epileptiform abnormalities over 16-24 hours. In 46%, treatment was changed based on continuous video-EEG. This study indicates that if continuous video-EEG is not available, a 30-minute EEG in the ICU has a substantial diagnostic yield and will lead to the detection of the majority of epileptiform abnormalities. In a small percentage of patients, continuous video-EEG will lead to the detection of additional epileptiform abnormalities. In a sub-population, with a history of seizures prior to the initiation of EEG recording, the benefits of continuous video-EEG in monitoring seizure activity and influencing treatment may be greater.

  1. Dietary Supplements for Exercise and Athletic Performance

    MedlinePlus

    ... Sodium bicarbonate Sodium bicarbonate is commonly known as baking soda. Exercising intensely over several minutes causes muscles ... weight, or about 4 to 5 teaspoons of baking soda. Some people find this amount of sodium ...

  2. Vascular Uptake of Six Rehydration Drinks at Rest and Exercise

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Geelen, G.; Jackson, C. G. R.; Saumet, J.-L.; Juhos, L. T.; Keil, L. C.; Fegan-Meyer, D.; Dearborn, A.; Hinghofer-Szalkay, H.; Whittam, J. H.

    1996-01-01

    A report presents data on the effectiveness of each of six rehydration fluids in restoring total body water and plasma volume in human subjects during rest and exercise. One of the six fluids was water sweetened with aspartame: the others were water containing various amounts of sodium chloride and/or sodium citrate, plus various amounts of aspartame and/or other carbohydrates. In one experiment, five men who had previously dehydrated themselves for 24 hours drank one of the rehydration fluids, then sat for 70 minutes. Pretest plasma volumes were measured and changes in plasma volumes were calculated. This procedure was repeated at weekly intervals until all six rehydration fluids had been tested. Another similar experiment involved four men who exercised on a cycle ergometer for 70 minutes in the supine position after drinking the fluids.

  3. Tourniquet use in orthopedic surgery: a descriptive survey study among Turkish orthopedic surgeons and residents in Istanbul.

    PubMed

    Yalçınkaya, Merter; Sökücü, Sami; Erdoğan, Sinan; Kabukçuoğlu, Yavuz S

    2014-01-01

    The aim of this study was to investigate and interpret the trends in tourniquet use and the accuracy of knowledge among Turkish orthopedic physicians through face-to-face survey. Turkish orthopedic physicians actively practicing operative orthopedics were questioned in a 12 question face-to-face survey. Personal information of physicians, preferred cuff pressure (CP) and tourniquet inflation time (TIT) and the source of the information for these preferences were questioned. Answers gathered were analyzed statistically. The survey was completed by 211 orthopedic physicians. Mean preferred CP and TIT was 247.1 mmHg and 108.6 minutes, respectively, in the upper limb (UL) and 345.02 mmHg and 122.4 minutes, respectively, in the lower limb (LL). A statistically significant correlation was found between the amount of pressure preferred in the LL and the years of practice; longer the years in practice, higher the amount of pressure preferred (r=0.144, p=0.04). Tourniquets were used for a maximum period of 120 minutes for the UL by 95.7% of participants and for the LL by 84.8%. The amount of CP used by the orthopedic physicians surveyed is inconsistent with the literature with frequent use of CP higher than those scientifically recommended. The outcomes of the survey should be cautionary for orthopedic physicians to review the current utilization and replace personal teachings and experience-based methods with evidence-based best practices for tourniquet application.

  4. Detection of 3-Minute Oscillations in Full-Disk Lyman-alpha Emission During A Solar Flare

    NASA Astrophysics Data System (ADS)

    Milligan, R. O.; Ireland, J.; Fleck, B.; Hudson, H. S.; Fletcher, L.; Dennis, B. R.

    2017-12-01

    We report the detection of chromospheric 3-minute oscillations in disk-integrated EUV irradiance observations during a solar flare. A wavelet analysis of detrended Lyman-alpha (from GOES/EUVS) and Lyman continuum (from SDO/EVE) emission from the 2011 February 15 X-class flare revealed a 3-minute period present during the flare's main phase. The formation temperature of this emission locates this radiation to the flare's chromospheric footpoints, and similar behaviour is found in the SDO/AIA 1600A and 1700A channels, which are dominated by chromospheric continuum. The implication is that the chromosphere responds dynamically at its acoustic cutoff frequency to an impulsive injection of energy. Since the 3-minute period was not found at hard X-ray energies (50-100 keV) in RHESSI data we can state that this 3-minute oscillation does not depend on the rate of energization of, or energy deposition by, non-thermal electrons. However, a second period of 120 s found in both hard X-ray and chromospheric emission is consistent with episodic electron energization on 2-minute timescales. Our finding on the 3-minute oscillation suggests that chromospheric mechanical energy should be included in the flare energy budget, and the fluctuations in the Lyman-alpha line may influence the composition and dynamics of planetary atmospheres during periods of high activity.

  5. Throughfall under a teak plantation in Thailand: a multifactorial analysis on the effects of canopy phenology and meteorological conditions

    NASA Astrophysics Data System (ADS)

    Tanaka, N.; Levia, D. F., Jr.; Igarashi, Y.; Nanko, K.; Yoshifuji, N.; Tanaka, K.; Chatchai, T.; Suzuki, M.; Kumagai, T.

    2014-12-01

    Teak (Tectona grandis Linn. f.) plantations cover vast areas throughout Southeast Asia and are of great economic importance. This study has sought to increase our understanding of throughfall inputs under teak by analyzing the abiotic and biotic factors governing throughfall amounts and throughfall ratios in relation to three canopy phenophases (leafless, leafing, and leafed). There is no rain during the brief leaf senescence phenophase. Daily data was available for both throughfall volumes and depths as well as leaf area index. Detailed meteorological data were available in situ every ten minutes. Leveraging this high-resolution field data, we employed boosted regression trees (BRT) analysis to identify the primary controls on throughfall amount and ratio during each of the three canopy phenophases. Whereas throughfall amounts were always dominated by the magnitude of rainfall (as expected), throughfall ratios were governed by a suite of predictor variables during each phenophase. The BRT analysis demonstrated that throughfall ratio in the leafless phase was most influenced (in descending order of importance) by air temperature, rainfall amount, maximum wind speed, and rainfall intensity. Throughfall ratio in the leafed phenophase was dominated by rainfall amount which exerted 54.0% of the relative influence. The leafing phenophase was an intermediate case where rainfall amount, air temperature, and vapor pressure deficit were most important. Our results highlight the fact that throughfall ratios are differentially influenced by a suite of meteorological variables during leafless, leafing, and leafed phenophases. Abiotic variables (rainfall amount, air temperature, vapor pressure deficit, and maximum wind speed) trumped leaf area index and stand density in their effect on throughfall ratio. The leafing phenophase, while transitional in nature and short in duration, has a detectable and unique impact on water inputs to teak plantations. Further work is clearly needed to better gauge the importance of the leaf emergence period to the stemflow hydrology and forest biogeochemistry of teak plantations.

  6. Comparasion of Cloud Cover restituted by POLDER and MODIS

    NASA Astrophysics Data System (ADS)

    Zeng, S.; Parol, F.; Riedi, J.; Cornet, C.; Thieuxleux, F.

    2009-04-01

    PARASOL and AQUA are two sun-synchronous orbit satellites in the queue of A-Train satellites that observe our earth within a few minutes apart from each other. Aboard these two platforms, POLDER and MODIS provide coincident observations of the cloud cover with very different characteristics. These give us a good opportunity to study the clouds system and evaluate strengths and weaknesses of each dataset in order to provide an accurate representation of global cloud cover properties. This description is indeed of outermost importance to quantify and understand the effect of clouds on global radiation budget of the earth-atmosphere system and their influence on the climate changes. We have developed a joint dataset containing both POLDER and MODIS level 2 cloud products collocated and reprojected on a common sinusoidal grid in order to make the data comparison feasible and veracious. Our foremost work focuses on the comparison of both spatial distribution and temporal variation of the global cloud cover. This simple yet critical cloud parameter need to be clearly understood to allow further comparison of the other cloud parameters. From our study, we demonstrate that on average these two sensors both detect the clouds fairly well. They provide similar spatial distributions and temporal variations:both sensors see high values of cloud amount associated with deep convection in ITCZ, over Indonesia, and in west-central Pacific Ocean warm pool region; they also provide similar high cloud cover associated to mid-latitude storm tracks, to Indian monsoon or to the stratocumulus along the west coast of continents; on the other hand small cloud amounts that typically present over subtropical oceans and deserts in subsidence aeras are well identified by both POLDER and MODIS. Each sensor has its advantages and inconveniences for the detection of a particular cloud types. With higher spatial resolution, MODIS can better detect the fractional clouds thus explaining as one part of a positive bias in any latitude and in any viewing angle with an order of 10% between the POLDER cloud amount and the so-called MODIS "combined" cloud amount. Nevertheless it is worthy to note that a negative bias of about 10% is obtained between the POLDER cloud amount and the MODIS "day-mean" cloud amount. Main differences between the two MODIS cloud amount values are known to be due to the filtering of remaining aerosols or cloud edges. due to both this high spatial resolution of MODIS and the fact that "combined" cloud amount filters cloud edges, we can also explain why appear the high positive bias regions over subtropical ocean in south hemisphere and over east Africa in summer. Thanks to several channels in the thermal infrared spectral domain, MODIS detects probably much better the thin cirrus especially over land, thus causing a general negative bias for ice clouds. The multi-spectral capability of MODIS also allows for a better detection of low clouds over snow or ice, Hence the (POLDER-MODIS) cloud amount difference is often negative over Greenland, Antarctica, and over the continents at middle-high latitudes in spring and autumn associated to the snow coverage. The multi-spectral capability of MODIS also makes the discrimination possible between the biomass burning aerosols and the fractional clouds over the continents. Thus a positive bias appears in central Africa in summer and autumn associated to important biomass burning events. Over transition region between desert and non-desert, the presence of large negative bias (POLDER-MODIS) of cloud amount maybe partly due to MODIS pixel falsely labeled the desert as cloudy, where MODIS algorithm uses static desert mask. This is clearly highlighted in south of Sahara in spring and summer where we find a bias negative with an order of -0.1. What is more, thanks to its multi-angular capability, POLDER can discriminate the sun-glint region thus minimizing the dependence of cloud amount on view angle. It makes the detection of high clouds easier over a black surface thanks to its polarization character.

  7. Massively Parallel Rogue Cell Detection Using Serial Time-Encoded Amplified Microscopy of Inertially Ordered Cells in High Throughput Flow

    DTIC Science & Technology

    2011-08-01

    further chemical analysis of the cells. While in our proof-of-concept demonstration, we showed high- throughput screening of budding yeast and...of 8.0 mW/cm2 through the transparency mask for 90 seconds. The wafer was baked again at 95°C for 4 minutes then developed in SU-8 developer...sonicated in isopropanol for 5 minutes, sonicated in deionized H2O for 5 minutes, and baked at 65°C for at least 30 minutes. Holes were punched

  8. 40 CFR 434.64 - Procedure and method detection limit for measurement of settleable solids.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... thoroughly mixed sample. Allow to settle undisturbed for 45 minutes. Gently stir along the inside surface of the cone with a stirring rod. Allow to settle undisturbed for 15 minutes longer. Record the volume of...

  9. 40 CFR 434.64 - Procedure and method detection limit for measurement of settleable solids.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... thoroughly mixed sample. Allow to settle undisturbed for 45 minutes. Gently stir along the inside surface of the cone with a stirring rod. Allow to settle undisturbed for 15 minutes longer. Record the volume of...

  10. Calibrating ultrasonic test equipment for checking thin metal strip stock

    NASA Technical Reports Server (NTRS)

    Peterson, R. M.

    1967-01-01

    Calibration technique detects minute laminar-type discontinuities in thin metal strip stock. Patterns of plastic tape are preselected to include minutely calculated discontinuities and the tape is applied to the strip stock to intercept the incident sonic beam.

  11. Disposable pen-shaped capillary gel electrophoresis cartridge for fluorescence detection of bio-molecules

    NASA Astrophysics Data System (ADS)

    Amirkhanian, Varoujan; Tsai, Shou-Kuan

    2014-03-01

    We introduce a novel and cost-effective capillary gel electrophoresis (CGE) system utilizing disposable pen-shaped gelcartridges for highly efficient, high speed, high throughput fluorescence detection of bio-molecules. The CGE system has been integrated with dual excitation and emission optical-fibers with micro-ball end design for fluorescence detection of bio-molecules separated and detected in a disposable pen-shaped capillary gel electrophoresis cartridge. The high-performance capillary gel electrophoresis (CGE) analyzer has been optimized for glycoprotein analysis type applications. Using commercially available labeling agent such as ANTS (8-aminonapthalene-1,3,6- trisulfonate) as an indicator, the capillary gel electrophoresis-based glycan analyzer provides high detection sensitivity and high resolving power in 2-5 minutes of separations. The system can hold total of 96 samples, which can be automatically analyzed within 4-5 hours. This affordable fiber optic based fluorescence detection system provides fast run times (4 minutes vs. 20 minutes with other CE systems), provides improved peak resolution, good linear dynamic range and reproducible migration times, that can be used in laboratories for high speed glycan (N-glycan) profiling applications. The CGE-based glycan analyzer will significantly increase the pace at which glycoprotein research is performed in the labs, saving hours of preparation time and assuring accurate, consistent and economical results.

  12. Detecting invisible bacillus spores on surfaces using a portable surface-enhanced Raman analyzer

    NASA Astrophysics Data System (ADS)

    Farquharson, Stuart; Inscore, Frank; Sperry, Jay F.

    2006-10-01

    Since the distribution of anthrax causing spores through the U.S. Postal System in the autumn of 2001, numerous methods have been developed to detect spores with the goal of minimizing casualties. During and following an attack it is also important to detect spores on surfaces, to assess extent of an attack, to quantify risk of infection by contact, as well as to evaluate post-attack clean-up. To perform useful measurements, analyzers and/or methods must be capable of detecting as few as 10 spores/cm2, in under 5-minutes, with little or no sample preparation or false-positive responses, using a portable device. In an effort to develop such a device, we have been investigating the ability of surfaceenhanced Raman spectroscopy (SERS) to detect dipicolinic acid (DPA) as a chemical signature of bacilli spores. In 2003 we employed SERS to measure DPA extracted from a 10,000 spores per μL sample using hot dodecylamine. Although the entire measurement was performed in 2 minutes, the need to heat the dodecylamine limits field portability of the method. Here we describe the use of a room temperature digesting agent in combination with SERS to detect 220 spores collected from a surface in a 1 μL sample within 3 minutes.

  13. The effects of QuikClot Combat Gauze on hemorrhage control in the presence of hemodilution.

    PubMed

    Johnson, Don; Agee, Samantha; Reed, Amanda; Gegel, Brian; Burgert, James; Gasko, John; Loughren, Michael

    2012-01-01

    Although hemostatic agents may be effective at stopping hemorrhage, they may fail because of hemodilution from intravenous fluids. The purpose of this study was to investigate the effects of QuikClot Combat Gauze (QCG) on rebleeding in a class II hemorrhage in the presence of hemodilution in a lethal femoral injury. This was a prospective experimental, between swine subjects design. Pigs were assigned to one of two groups: QCG (n=15) or control (n=15). Thirty percent of the pig's blood was exsanguinated and then a 3:1 ratio of ringers lactate was administered. A groin injury was created by transecting the femoral artery and vein to simulate a battlefield injury and allowed to bleed for one minute. After one minute of hemorrhage, proximal pressure was applied to the injury, and QCG was placed into the wound followed by standard wound packing. The control group underwent the same procedures with the exception of the hemostatic agent. For both groups, 5 minutes of direct pressure was applied to the wound followed by a standard pressure dressing. Dressings were removed after 30 minutes, and the amount of hemorrhage was calculated in milliliters for each group for a period of 5 minutes. An activated clotting time was used to exclude any pigs with coagulation pathology. A multivariate analysis of variance indicated that there were no significant differences in the groups relative to weight, amount of one minute hemorrhage, fluid deficit replacement, blood volume, and the activated clotting time (P>.05) indicating that the groups were equivalent on these parameters. A t test indicated that there was significantly less bleeding (P=.002) in the QCG group (36 mL±112 mL) compared to the control group (340 mL±297 ml). QCG produces a robust clot that can more effectively tolerate hemodilution compared to a control group.

  14. METABOLIC SYNDROME AND DAILY AMBULATION IN CHILDREN, ADOLESCENTS, AND YOUNG ADULTS

    PubMed Central

    Gardner, Andrew W.; Parker, Donald E.; Krishnan, Sowmya; Chalmers, Laura J.

    2012-01-01

    Purposes To compare daily ambulatory measures in children, adolescents, and young adults with and without metabolic syndrome, and to assess which metabolic syndrome components, demographic measures, and body composition measures are associated with daily ambulatory measures. Methods Two-hundred fifty subjects between the ages of 10 and 30 years were assessed on metabolic syndrome components, demographic and clinical measures, body fat percentage, and daily ambulatory strides, durations, and cadences during seven consecutive days. Forty-five of the 250 subjects had metabolic syndrome, as defined by the International Diabetes Federation. Results Subjects with metabolic syndrome ambulated at a slower daily average cadence than those without metabolic syndrome (13.6 ± 2.2 strides/min vs. 14.9 ± 3.2 strides/min; p=0.012), and they had slower cadences for continuous durations of 60 minutes (p=0.006), 30 minutes (p=0.005), 20 minutes (p=0.003), 5 minutes (p=0.002), and 1 minute (p=0.001). However, the total amount of time spent ambulating each day was not different (p=0.077). After adjustment for metabolic syndrome status, average cadence is linearly associated with body fat percentage (p<0.001) and fat mass (p<0.01). Group difference in average cadence was no longer significant after adjusting for body fat percentage (p=0.683) and fat mass (p=0.973). Conclusion Children, adolescents, and young adults with metabolic syndrome ambulate more slowly and take fewer strides throughout the day than those without metabolic syndrome, even though the total amount of time spent ambulating is not different. Furthermore, the detrimental influence of metabolic syndrome on ambulatory cadence is primarily a function of body fatness. PMID:22811038

  15. How repeated 15-minute assertiveness training sessions reduce wrist cutting in patients with borderline personality disorder.

    PubMed

    Hayakawa, Masaya

    2009-01-01

    The aim of this work was to examine a possible treatment for patients with borderline personality disorder who have wrist-cutting syndrome, a condition characterized by repeated, superficial wrist cutting in a non-suicidal fashion. Within the current healthcare system in Japan, the average amount of time a doctor can spend with a psychiatric outpatient is about 8 to 15 minutes. We, therefore, examined whether repeated 15-minute psychotherapy sessions to improve patient assertiveness would be effective for reducing wrist cutting and possibly other forms of self-mutilation. We treated 13 patients diagnosed with borderline personality disorder and wrist-cutting syndrome with assertiveness training during 15-minute, biweekly therapy sessions over a course of one to four years. At the conclusion of psychotherapeutic treatment, 69% of outpatients showed a statistically significant reduction in wrist-cutting behavior.

  16. An analysis of antioxidants, organoleptics and hedonics with variations of boiling time in Jasmine tea and Jasmine root tea a study on Kaliprau, Pemalang

    NASA Astrophysics Data System (ADS)

    Arifan, Fahmi; Winarni, Sri; Handoyo, Gentur; Nurdiana, Asri; Nabila Rahma H, Afkar; Risdiyanti, Sri

    2018-05-01

    There are so many jasmine plantations without any preservation and post production in Kaliprau, Pemalang. The aims of this research are analyzing the amount of antioxidant and organoleptic-hedonic test. The measurement of antioxidant used in this research is using DPPH. The organoleptic and hedonic test on 25 respondents. Jasmines that been used on this research are the flower and the root part. Through the test, some results have been found from the jasmine tea’s sampling with the boiling time of 15 minutes and it contain antioxidant for about 55.0% and 74.84% for the jasmine root tea. Whereas for the boiling time of 30 minutes, it contained 54.00% of antioxidant for the jasmine tea and 84.00% of antioxidant in jasmine root tea. Jasmine tea and jasmine root tea contains flavonoids. Despite the large amount of antioxidant were found in jasmine tea and jasmine root tea (50-100%). There’s a decreasing of antioxidant amount found in the samples, along with the prolonged boiling time. 84% of tresponden like the scent, flavor, color and the texture of jasmine tea and jasmine root tea. These products are finally accepted by the people and have its large amount of antioxidant contain for the jasmine tea.

  17. Automatic bio-sample bacteria detection system

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Colburn, M.; Kelbaugh, B. N.; Picciolo, G. L.

    1971-01-01

    Electromechanical device analyzes urine specimens in 15 minutes and processes one sample per minute. Instrument utilizes bioluminescent reaction between luciferase-luciferin mixture and adenosine triphosphate (ATP) to determine number of bacteria present in the sample. Device has potential application to analysis of other body fluids.

  18. A study of benzocaine gel dosing for toothache.

    PubMed

    Hersh, Elliot V; Stoopler, Eric T; Secreto, Stacey A; DeRossi, Scott S

    2005-01-01

    This pilot study evaluated subject compliance with a proposed OTC label with improved dosing directions for self-application of a 20% benzocaine gel for toothache pain, and assessed the methodology for evaluating efficacy in a future pivotal study of benzocaine gel. It was hypothesized that > or = 75% of subjects would apply < or = 400 mg of product (80 mg benzocaine). Exploratory analyses of efficacy were also performed. Thirty patients with spontaneous pain of moderate or severe intensity from a single tooth due to caries, a lost restoration, or a fracture entered this randomized, parallel group, double-blind study. Before self-applying 20% benzocaine gel or placebo, patients read a label containing new dosing directions, including a picture of how much product to apply to their tooth and the surrounding gingival tissues. The amount applied was determined by weighing the tube before and after dosing. Following dosing, pain intensity and relief were recorded every five minutes through 30 minutes, then every ten minutes through 120 minutes. Responders were defined as those subjects who experienced at least a one-unit reduction in pain intensity from baseline at two consecutive time points within the first 20 minutes. Onset of meaningful relief was recorded using a stopwatch. The percentage of responders was compared using the Mantel-Haenszel test. ANOVA was employed to test for differences in Pain Relief Combined with Pain Intensity Difference (PRID), and the areas under the curve at 30, 60, 90, and 120 minutes for this measure (SPRID). Median onset and duration times were compared using the Cox proportional hazards model. Adverse events were recorded if and when they occurred. It was found that 86.7% of the subjects (26/30) applied < or = 375 mg of product (mean +/- SD = 327.7 +/- 276.8 mg). The benzocaine group had a significantly higher (p = 0.022) responder rate (86.7%) than the placebo group (46.7%). Significant differences in favor of the benzocaine group were also recorded for PRID at 10, 15, and 30 minutes (p < 0.05) and SPRID-30 (p = 0.037). Median onset and duration times were 8.3 minutes and > 115 minutes for the benzocaine group, >120 minutes and 5 minutes for the placebo group. There were no adverse events recorded in the study. The improved dosing directions resulted in a high percentage of subjects self-applying an appropriate amount of benzocaine gel or matching placebo. The label and study methodology appear suitable for a pivotal dose-response study in subjects with toothache pain. While the current study was not statistically powered to make firm efficacy conclusions, 20% benzocaine gel appeared more efficacious than placebo, providing a rapid onset of pain relief and a relatively long duration of action.

  19. Approaching near real-time biosensing: microfluidic microsphere based biosensor for real-time analyte detection.

    PubMed

    Cohen, Noa; Sabhachandani, Pooja; Golberg, Alexander; Konry, Tania

    2015-04-15

    In this study we describe a simple lab-on-a-chip (LOC) biosensor approach utilizing well mixed microfluidic device and a microsphere-based assay capable of performing near real-time diagnostics of clinically relevant analytes such cytokines and antibodies. We were able to overcome the adsorption kinetics reaction rate-limiting mechanism, which is diffusion-controlled in standard immunoassays, by introducing the microsphere-based assay into well-mixed yet simple microfluidic device with turbulent flow profiles in the reaction regions. The integrated microsphere-based LOC device performs dynamic detection of the analyte in minimal amount of biological specimen by continuously sampling micro-liter volumes of sample per minute to detect dynamic changes in target analyte concentration. Furthermore we developed a mathematical model for the well-mixed reaction to describe the near real time detection mechanism observed in the developed LOC method. To demonstrate the specificity and sensitivity of the developed real time monitoring LOC approach, we applied the device for clinically relevant analytes: Tumor Necrosis Factor (TNF)-α cytokine and its clinically used inhibitor, anti-TNF-α antibody. Based on the reported results herein, the developed LOC device provides continuous sensitive and specific near real-time monitoring method for analytes such as cytokines and antibodies, reduces reagent volumes by nearly three orders of magnitude as well as eliminates the washing steps required by standard immunoassays. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Quantitative determination of triterpenoids and formononetin in rhizomes of black cohosh (Actaea racemosa) and dietary supplements by using UPLC-UV/ELS detection and identification by UPLC-MS.

    PubMed

    Avula, Bharathi; Wang, Yan-Hong; Smillie, Troy J; Khan, Ikhlas A

    2009-03-01

    A UPLC-UV/ELSD method has been developed for analysis of major triterpenoids and formononetin in ACTAEA RACEMOSA L. (family Ranunculaceae) samples. The best results were obtained with an Acquity UPLC BEH C18 (100 mmx2.1 mm, i. d., 1 microm) column system using gradient elution with a mobile phase consisting of water and acetonitrile:methanol (7:3) at a constant flow rate of 0.3 mL/min. Owing to their low UV absorption, the triterpene saponins were detected by evaporative light scattering. Within 5.5 minutes, three main triterpenoid glycosides [cimiracemoside A, 23- EPI-26-deoxyactein, and actein] and an isoflavonoid, formononetin, could be separated, with detection limits of 5, 5, 10, and 0.01 microg/mL, respectively. The method was successfully used to analyze different Actaea racemosa market products as well as to distinguish between two other ACTAEA species. There was a significant variability in the amounts of the selected triterpene glycosides for the products containing black cohosh and rhizomes of black cohosh. The isoflavone formononetin was not detected in the samples analyzed. LC-MS coupled with the electrospray ionization (ESI) interface method is described for the identification of formononetin and triterpenoid glycosides in plant samples and dietary supplements that claim to contain black cohosh and different species of Actaea.

  1. Physical activity in low-income postpartum women.

    PubMed

    Wilkinson, Susan; Huang, Chiu-Mieh; Walker, Lorraine O; Sterling, Bobbie Sue; Kim, Minseong

    2004-01-01

    To validate the 7-day physical activity recall (PAR), including alternative PAR scoring algorithms, using pedometer readings with low-income postpartum women, and to describe physical activity patterns of a low-income population of postpartum women. Forty-four women (13 African American, 19 Hispanic, and 12 White) from the Austin New Mothers Study (ANMS) were interviewed at 3 months postpartum. Data were scored alternatively according to the Blair (sitting treated as light activity) and Welk (sitting excluded from light activity and treated as rest) algorithms. Step counts based on 3 days of wearing pedometers served as the validation measure. Using the Welk algorithm, PAR components significantly correlated with step counts were: minutes spent in light activity, total activity (sum of light to very hard activity), and energy expenditure. Minutes spent in sitting were negatively correlated with step counts. No PAR component activities derived with the Blair algorithm were significantly related to step counts. The largest amount of active time was spent in light activity: 384.4 minutes with the Welk algorithm. Mothers averaged fewer than 16 minutes per day in moderate or high intensity activity. Step counts measured by pedometers averaged 6,262 (SD = 2,712) per day. The findings indicate support for the validity of the PAR as a measure of physical activity with low-income postpartum mothers when scored according to the Welk algorithm. On average, low-income postpartum women in this study did not meet recommendations for amount of moderate or high intensity physical activity.

  2. A Search for Early Optical Emission at Gamma-Ray Burst Locations by the Solar Mass Ejection Imager (SMEI)

    NASA Technical Reports Server (NTRS)

    Band, David L.; Buffington, Andrew; Jackson, Bernard V.; Hick, P. Paul; Smith, Aaron C.

    2005-01-01

    The Solar Mass Ejection Imager (SMEI) views nearly every point on the sky once every 102 minutes and can detect point sources as faint as R approx. 10th magnitude. Therefore, SMEI can detect or provide upper limits for the optical afterglow from gamma-ray bursts in the tens of minutes after the burst when different shocked regions may emit optically. Here we provide upper limits for 58 bursts between 2003 February and 2005 April.

  3. Tissue distribution of enrofloxacin after intramammary or simulated systemic administration in isolated perfused sheep udders.

    PubMed

    López Cadenas, Cristina; Fernández Martínez, Nélida; Sierra Vega, Matilde; Diez Liébana, Maria J; Gonzalo Orden, Jose M; Sahagún Prieto, Ana M; García Vieitez, Juan J

    2012-11-01

    To determine the tissue distribution of enrofloxacin after intramammary or simulated systemic administration in isolated perfused sheep udders by measuring its concentration at various sample collection sites. 26 udders (obtained following euthanasia) from 26 healthy lactating sheep. For each isolated udder, 1 mammary gland was perfused with warmed, gassed Tyrode solution. Enrofloxacin (1 g of enrofloxacin/5 g of ointment) was administered into the perfused gland via the intramammary route or systemically via the perfusion fluid (equivalent to a dose of 5 mg/kg). Samples of the perfusate were obtained every 30 minutes for 180 minutes; glandular tissue samples were obtained at 2, 4, 6, and 8 cm from the teat base after 180 minutes. The enrofloxacin content of the perfusate and tissue samples was analyzed via high-performance liquid chromatography with UV detection. After intramammary administration, maximun perfusate enrofloxacin concentration was detected at 180 minutes and, at this time, mean tissue enrofloxacin concentration was detected and mean tissue enrofloxacin concentration was 123.80, 54.48, 36.72, and 26.42 μg/g of tissue at 2, 4, 6, and 8 cm from the teat base, respectively. Following systemic administration, perfusate enrofloxacin concentration decreased with time and, at 180 minutes, tissue enrofloxacin concentrations ranged from 40.38 to 35.58 μg/g of tissue. By 180 minutes after administration via the intramammary or systemic route in isolated perfused sheep mammary glands, mean tissue concentration of enrofloxacin was greater than the minimum inhibitory concentration required to inhibit growth of 90% of many common mastitis pathogens in sheep. Use of either route of administration (or in combination) appears suitable for the treatment of acute mastitis in sheep.

  4. Biological cell as a soft magnetoelectric material: Elucidating the physical mechanisms underpinning the detection of magnetic fields by animals

    NASA Astrophysics Data System (ADS)

    Krichen, S.; Liu, L.; Sharma, P.

    2017-10-01

    Sharks, birds, bats, turtles, and many other animals can detect magnetic fields. Aside from using this remarkable ability to exploit the terrestrial magnetic field map to sense direction, a subset is also able to implement a version of the so-called geophysical positioning system. How do these animals detect magnetic fields? The answer to this rather deceptively simple question has proven to be quite elusive. The currently prevalent theories, while providing interesting insights, fall short of explaining several aspects of magnetoreception. For example, minute magnetic particles have been detected in magnetically sensitive animals. However, how is the detected magnetic field converted into electrical signals given any lack of experimental evidence for relevant electroreceptors? In principle, a magnetoelectric material is capable of converting magnetic signals into electricity (and vice versa). This property, however, is rare and restricted to a rather small set of exotic hard crystalline materials. Indeed, such elements have never been detected in the animals studied so far. In this work we quantitatively outline the conditions under which a biological cell may detect a magnetic field and convert it into electrical signals detectable by biological cells. Specifically, we prove the existence of an overlooked strain-mediated mechanism and show that most biological cells can act as nontrivial magnetoelectric materials provided that the magnetic permeability constant is only slightly more than that of a vacuum. The enhanced magnetic permeability is easily achieved by small amounts of magnetic particles that have been experimentally detected in magnetosensitive animals. Our proposed mechanism appears to explain most of the experimental observations related to the physical basis of magnetoreception.

  5. Use of bovine recombinant prion protein and real-time quaking-induced conversion to detect cattle transmissible mink encephalopathy prions and discriminate classical and atypical L- and H-Type bovine spongiform encephalopathy.

    PubMed

    Hwang, Soyoun; Greenlee, Justin J; Nicholson, Eric M

    2017-01-01

    Prions are amyloid-forming proteins that cause transmissible spongiform encephalopathies through a process involving conversion from the normal cellular prion protein to the pathogenic misfolded conformation (PrPSc). This conversion has been used for in vitro assays including serial protein misfolding amplification and real-time quaking induced conversion (RT-QuIC). RT-QuIC can be used for the detection of prions in a variety of biological tissues from humans and animals. Extensive work has been done to demonstrate that RT-QuIC is a rapid, specific, and highly sensitive prion detection assay. RT-QuIC uses recombinant prion protein to detect minute amounts of PrPSc. RT-QuIC has been successfully used to detect PrPSc from different prion diseases with a variety of substrates including hamster, human, sheep, bank vole, bovine and chimeric forms of prion protein. However, recombinant bovine prion protein has not been used to detect transmissible mink encephalopathy (TME) or to differentiate types of bovine spongiform encephalopathy (BSE) in samples from cattle. We evaluated whether PrPSc from TME and BSE infected cattle can be detected with RT-QuIC using recombinant bovine prion proteins, and optimized the reaction conditions to specifically detect cattle TME and to discriminate between classical and atypical BSE by conversion efficiency. We also found that substrate composed of the disease associated E211K mutant protein can be effective for the detection of TME in cattle and that wild type prion protein appears to be a practical substrate to discriminate between the different types of BSEs.

  6. Multiplex polymerase chain reaction assay for the detection of minute virus of mice and mouse parvovirus infections in laboratory mice.

    PubMed

    Wang, K W; Chueh, L L; Wang, M H; Huang, Y T; Fang, B H; Chang, C Y; Fang, M C; Chou, J Y; Hsieh, S C; Wan, C H

    2013-04-01

    Mouse parvoviruses are among the most prevalent infectious pathogens in contemporary mouse colonies. To improve the efficiency of routine screening for mouse parvovirus infections, a multiplex polymerase chain reaction (PCR) assay targeting the VP gene was developed. The assay detected minute virus of mice (MVM), mouse parvovirus (MPV) and a mouse housekeeping gene (α-actin) and was able to specifically detect MVM and MPV at levels as low as 50 copies. Co-infection with the two viruses with up to 200-fold differences in viral concentrations can easily be detected. The multiplex PCR assay developed here could be a useful tool for monitoring mouse health and the viral contamination of biological materials.

  7. Stability of cyclosporine solutions stored in polypropylene-polyolefin bags and polypropylene syringes.

    PubMed

    Li, Mengqing; Forest, Jean-Marc; Coursol, Christian; Leclair, Grégoire

    2011-09-01

    The stability of cyclosporine diluted to 0.2 or 2.5 mg/mL with 0.9% sodium chloride injection or 5% dextrose injection and stored in polypropylene-polyolefin containers or polypropylene syringes was evaluated. Intravenous cyclosporine solutions (0.2 and 2.5 mg/mL) were aseptically prepared and transferred to 250-mL polypropylene-polyolefin bags or 60-mL polypropylene syringes. Chemical stability was measured using a stability-indicating high-performance liquid chromatography (HPLC) assay. Physical stability was assessed by visual inspection and a dynamic light scattering (DLS) method. After 14 days, HPLC assay showed that the samples of i.v. cyclosporine stored in polypropylene-polyolefin bags remained chemically stable (>98% of initial amount remaining); the physical stability of the samples was confirmed by DLS and visual inspection. The samples stored in polypropylene syringes were found to contain an impurity (attributed to leaching of a syringe component by the solution) that could be detected by HPLC after 1 day; on further investigation, no leaching was detected when the syringes were exposed to undiluted i.v. cyclosporine 50 mg/mL for 10 minutes. Samples of i.v. cyclosporine solutions of 0.2 and 2.5 mg/mL diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 25 °C in polypropylene-polyolefin bags were physically and chemically stable for at least 14 days. When stored in polypropylene syringes, the samples were contaminated by an impurity within 1 day; however, the short-term (i.e., ≤10 minutes) use of the syringes for the preparation and transfer of i.v. cyclosporine solution is considered safe.

  8. A Community-based Healthy Living Promotion Program Improved Self-esteem Among Minority Children.

    PubMed

    Wong, William W; Ortiz, Christina L; Stuff, Janice E; Mikhail, Carmen; Lathan, Debra; Moore, Louis A; Alejandro, Mercedes E; Butte, Nancy F; Smith, Elliot O'Brian

    2016-07-01

    Improving self-esteem, dietary habits, and physical activity is essential for long-term success in childhood obesity prevention. The aim is to evaluate the effects of a healthy living promotion program, Healthy Kids-Houston, on BMI, dietary habits, self-esteem, and physical activity among minority children. The after-school program was implemented at community centers in low-income neighborhoods with close proximity to public schools. The program consisted of 3 6-week sessions. Each week, children attended 2 2-hour sessions. Each 2-hour session in the intervention included 90 minutes of structured physical activities and 30 minutes of nutrition and healthy habit lessons. The control group received typical enrichment programs. Outcomes were measured before the intervention and at the end of each 6-week session. We enrolled 877 children (age 10.2 ± 0.1 years (mean ± SE); body mass index z score: 1.49 ± 0.1; 52.0% boys; 72.6% Hispanic) in the program with 524 children received the intervention at 14 community centers and 353 children served as control at 10 community centers. The intervention led to no improvements in BMI z score (P = 0.78) and dietary habits (P = 0.46). Significant improvements (P ≤ 0.02) were detected in the amount of exercise that a child perceived to be required to offset a large meal and in several key self-esteem scores. No improvements were detected in physical activities (P ≥ 0.21). The improvement in some key self-esteem scores and nutrition knowledge may act as a mediator to motivate these children to adopt a healthier lifestyle in the future.

  9. Simultaneous teleseismic and geodetic observations of the stick-slip motion of an Antarctic ice stream.

    PubMed

    Wiens, Douglas A; Anandakrishnan, Sridhar; Winberry, J Paul; King, Matt A

    2008-06-05

    Long-period seismic sources associated with glacier motion have been recently discovered, and an increase in ice flow over the past decade has been suggested on the basis of secular changes in such measurements. Their significance, however, remains uncertain, as a relationship to ice flow has not been confirmed by direct observation. Here we combine long-period surface-wave observations with simultaneous Global Positioning System measurements of ice displacement to study the tidally modulated stick-slip motion of the Whillans Ice Stream in West Antarctica. The seismic origin time corresponds to slip nucleation at a region of the bed of the Whillans Ice Stream that is likely stronger than in surrounding regions and, thus, acts like an 'asperity' in traditional fault models. In addition to the initial pulse, two seismic arrivals occurring 10-23 minutes later represent stopping phases as the slip terminates at the ice stream edge and the grounding line. Seismic amplitude and average rupture velocity are correlated with tidal amplitude for the different slip events during the spring-to-neap tidal cycle. Although the total seismic moment calculated from ice rigidity, slip displacement, and rupture area is equivalent to an earthquake of moment magnitude seven (M(w) 7), seismic amplitudes are modest (M(s) 3.6-4.2), owing to the source duration of 20-30 minutes. Seismic radiation from ice movement is proportional to the derivative of the moment rate function at periods of 25-100 seconds and very long-period radiation is not detected, owing to the source geometry. Long-period seismic waves are thus useful for detecting and studying sudden ice movements but are insensitive to the total amount of slip.

  10. How to search for and use 'grey literature' in research.

    PubMed

    Coad, Jane; Hardicre, Jayne; Devitt, Patric

    An ever-growing amount of grey literature is available to nurses, including oral presentations, personal communication, leaflets, newspapers and magazines, unpublished research, internal reports and minutes of meetings. It can be an invaluable research resource.

  11. Development of a homogeneous assay format for p53 antibodies using fluorescence correlation spectroscopy

    NASA Astrophysics Data System (ADS)

    Neuweiler, Hannes; Scheffler, Silvia; Sauer, Markus

    2005-08-01

    The development of reliable methods for the detection of minute amounts of antibodies directly in homogeneous solution represents one of the major tasks in the current research field of molecular diagnostics. We demonstrate the potential of fluorescence correlation spectroscopy (FCS) in combination with quenched peptide-based fluorescence probes for sensitive detection of p53 antibodies directly in homogeneous solution. Single tryptophan (Trp) residues in the sequences of short, synthetic peptide epitopes of the human p53 protein efficiently quench the fluorescence of an oxazine fluorophore attached to the amino terminal ends of the peptides. The fluorescence quenching mechanism is thought to be a photoinduced electron transfer reaction from Trp to the dye enabled by the formation of intramolecular complexes between dye and Trp. Specific recognition of the epitope by the antibody confines the conformational flexibility of the peptide. Consequently, complex formation between dye and Trp is abolished and fluorescence is recovered. Using fluorescence correlation spectroscopy (FCS), antibody binding can be monitored observing two parameters simultaneously: the diffusional mobility of the peptide as well as the quenching amplitude induced by the conformational flexibility of the peptide change significantly upon antibody binding. Our data demonstrate that FCS in combination with fluorescence-quenched peptide epitopes opens new possibilities for the reliable detection of antibody binding events in homogeneous solution.

  12. Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoea.

    PubMed

    de Chazal, Philip; Heneghan, Conor; Sheridan, Elaine; Reilly, Richard; Nolan, Philip; O'Malley, Mark

    2003-06-01

    A method for the automatic processing of the electrocardiogram (ECG) for the detection of obstructive apnoea is presented. The method screens nighttime single-lead ECG recordings for the presence of major sleep apnoea and provides a minute-by-minute analysis of disordered breathing. A large independently validated database of 70 ECG recordings acquired from normal subjects and subjects with obstructive and mixed sleep apnoea, each of approximately eight hours in duration, was used throughout the study. Thirty-five of these recordings were used for training and 35 retained for independent testing. A wide variety of features based on heartbeat intervals and an ECG-derived respiratory signal were considered. Classifiers based on linear and quadratic discriminants were compared. Feature selection and regularization of classifier parameters were used to optimize classifier performance. Results show that the normal recordings could be separated from the apnoea recordings with a 100% success rate and a minute-by-minute classification accuracy of over 90% is achievable.

  13. Detection of Three-minute Oscillations in Full-disk Lyα Emission during a Solar Flare

    NASA Astrophysics Data System (ADS)

    Milligan, Ryan O.; Fleck, Bernhard; Ireland, Jack; Fletcher, Lyndsay; Dennis, Brian R.

    2017-10-01

    In this Letter we report the detection of chromospheric 3-minute oscillations in disk-integrated EUV irradiance observations during a solar flare. A wavelet analysis of detrended Lyα (from GOES/EUVS) and Lyman continuum (from Solar Dynamics Observatory (SDO)/EVE) emission from the 2011 February 15 X-class flare (SOL2011-02-15T01:56) revealed a ˜3 minute period present during the flare’s main phase. The formation temperature of this emission locates this radiation at the flare’s chromospheric footpoints, and similar behavior is found in the SDO/Atmospheric Imaging Assembly 1600 and 1700 Å channels, which are dominated by chromospheric continuum. The implication is that the chromosphere responds dynamically at its acoustic cutoff frequency to an impulsive injection of energy. Since the 3-minute period was not found at hard X-ray (HXR) energies (50-100 keV) in Reuven Ramaty High Energy Solar Spectroscopic Imager data we can state that this 3-minute oscillation does not depend on the rate of energization of non-thermal electrons. However, a second period of 120 s found in both HXR and chromospheric lightcurves is consistent with episodic electron energization on 2-minute timescales. Our finding on the 3-minute oscillation suggests that chromospheric mechanical energy should be included in the flare energy budget, and the fluctuations in the Lyα line may influence the composition and dynamics of planetary atmospheres during periods of high activity.

  14. AN EXTRAORDINARY OUTBURST OF THE MAGNETAR SWIFT J1822.3–1606

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakraborty, Manoneeta; Göğüş, Ersin

    2015-08-20

    The 2011 outburst of Swift J1822.3–1606 was extraordinary; periodic modulations at the spin period of the underlying neutron star were clearly visible, remarkably similar to what is observed during the decaying tail of magnetar giant flares. We investigated the temporal characteristics of X-ray emission during the early phases of the outburst. We performed a periodicity search with the spectral hardness ratio (HR) and found a coherent signal near the spin period of the neutron star, but with a lag of about 3 radians. Therefore, the HR is strongly anti-correlated with the X-ray intensity, which is also seen in the giantmore » flares. We studied the time evolution of the pulse profile and found that it evolves from a complex morphology to a much simpler shape within about a month. Pulse profile simplification also takes place during the giant flares, but on a much shorter timescale of about a few minutes. We found that the amount of energy emitted during the first 25 days of the outburst is comparable to what was detected in minutes during the decaying tail of giant flares. Based on these similarities, we suggest that the triggering mechanisms of the giant flares and the magnetar outbursts are likely the same. We propose that the trapped fireball that develops in the magnetosphere at the onset of the outburst radiates away efficiently in minutes in magnetars exhibiting giant flares, while in other magnetars, such as Swift J1822.3–1606, the efficiency of radiation of the fireball is not as high and, therefore, lasts much longer.« less

  15. Effects of combined electrical stimulation of the dorsal column and dorsal roots on wide-dynamic range neuronal activity in nerve-injured rats

    PubMed Central

    Yang, Fei; Zhang, Tong; Tiwari, Vinod; Shu, Bin; Zhang, Chen; Wang, Yun; Vera-Portocarrero, Louis P.; Raja, Srinivasa N.; Guan, Yun

    2015-01-01

    Objectives Electrical stimulation at the dorsal column (DC) and dorsal root (DR) may inhibit spinal wide-dynamic-range (WDR) neuronal activity in nerve-injured rats. The objective of this study was to determine if applying electrical conditioning stimulation (CS) at both sites provides additive or synergistic benefits. Materials and Methods By conducting in vivo extracellular recordings of WDR neurons in rats that had undergone L5 spinal nerve ligation, we tested whether combining 50 Hz CS at the two sites in either a concurrent (2.5 minutes) or alternate (5 minutes) pattern inhibits WDR neuronal activity better than CS at DC alone (5 minutes). The intensities of CS were determined by recording antidromic compound action potentials to graded stimulation at the DC and DR. We measured the current thresholds that resulted in the first detectable Aα/β waveform (Ab0) and the peak Aα/β waveform (Ab1) to select CS intensity at each site. The same number of electrical pulses and amount of current were delivered in different patterns to allow comparison. Results At a moderate intensity of 50%(Ab0+Ab1), different patterns of CS all attenuated the C-component of WDR neurons in response to graded intracutaneous electrical stimuli (0.1-10 mA, 2 ms), and inhibited windup in response to repetitive noxious stimuli (0.5 Hz). However, the inhibitory effects did not differ significantly between different patterns. At the lower intensity (Ab0), no CS inhibited WDR neurons. Conclusions These findings suggest that combined stimulation of DC and DR may not be superior to DC stimulation alone for inhibition of WDR neurons. PMID:26307526

  16. Anthropometric and performance characteristics of the German rugby union 7s team.

    PubMed

    Hohenauer, Erich; Rucker, Alfred M; Clarys, Peter; Küng, Ursula M; Stoop, Rahel; Clijsen, Ron

    2017-12-01

    Somatotyping is advantageous in sports for the optimal development of performance level and injury prevention. The aim of this study was to describe the anthropometric and physical performance characteristics of the German national rugby union 7s team. Seventeen male rugby players, classified as forwards (N.=9; 24.2±2.1 years) and backs (N.=8; 24.3±5.05 years) were assessed. Anthropometric measurements included: body height, weight, height to weight ratio (H/W), five skinfolds, biepicondylar humerus and femur breadth, upper arm- and calf girth, estimated lower body fat percentage and determination of the individual and mean somatotype. The physical performance tests included: sit-and-reach, handgrip strength, one minute of sit-ups, one minute of push-ups, vertical jump performance, peak power performance, bent arm hanging, 40-m sprint, and the Yo-Yo Intermittent Endurance Test. The forward players were significantly taller (P=0.003), heavier (P=0.001) with a smaller H/W (P=0.009) compared to the backs. Humerus and femur bone breadths (P<0.05) and flexed upper arm and calf girths (P<0.05) were significantly different between the groups. Handgrip strength left (P=0.04), one minute of sit-ups (P=0.03), and peak power output (P=0.015) were also significantly different between the groups. The data indicate that German forward and back players have a similar somatotype and performance level. However, a higher body mass of forward players could be advantageous in that their playing position is much more body contact intensive, and requires a significant amount of tackling. The nominative data of this study may assist coaches to detect weak links in rugby specific athletic performance.

  17. Sizing of single fluorescently stained DNA fragments by scanning microscopy

    PubMed Central

    Laib, Stephan; Rankl, Michael; Ruckstuhl, Thomas; Seeger, Stefan

    2003-01-01

    We describe an approach to determine DNA fragment sizes based on the fluorescence detection of single adsorbed fragments on specifically coated glass cover slips. The brightness of single fragments stained with the DNA bisintercalation dye TOTO-1 is determined by scanning the surface with a confocal microscope. The brightness of adsorbed fragments is found to be proportional to the fragment length. The method needs only minute amount of DNA, beyond inexpensive and easily available surface coatings, like poly-l-lysine, 3-aminoproyltriethoxysilane and polyornithine, are utilizable. We performed DNA-sizing of fragment lengths between 2 and 14 kb. Further, we resolved the size distribution before and after an enzymatic restriction digest. At this a separation of buffers or enzymes was unnecessary. DNA sizes were determined within an uncertainty of 7–14%. The proposed method is straightforward and can be applied to standardized microtiter plates. PMID:14602931

  18. Microchannel gel electrophoretic separation systems and methods for preparing and using

    DOEpatents

    Herr, Amy E; Singh, Anup K; Throckmorton, Daniel J

    2015-02-24

    A micro-analytical platform for performing electrophoresis-based immunoassays was developed by integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device. The microfluidic immunoassays are performed by gel electrophoretic separation and quantifying analyte concentration based upon conventional polyacrylamide gel electrophoresis (PAGE). To retain biological activity of proteins and maintain intact immune complexes, native PAGE conditions were employed. Both direct (non-competitive) and competitive immunoassay formats are demonstrated in microchips for detecting toxins and biomarkers (cytokines, c-reactive protein) in bodily fluids (serum, saliva, oral fluids). Further, a description of gradient gels fabrication is included, in an effort to describe methods we have developed for further optimization of on-chip PAGE immunoassays. The described chip-based PAGE immunoassay method enables immunoassays that are fast (minutes) and require very small amounts of sample (less than a few microliters). Use of microfabricated chips as a platform enables integration, parallel assays, automation and development of portable devices.

  19. Click Chemistry Mediated Functionalization of Vertical Nanowires for Biological Applications.

    PubMed

    Vutti, Surendra; Schoffelen, Sanne; Bolinsson, Jessica; Buch-Månson, Nina; Bovet, Nicolas; Nygård, Jesper; Martinez, Karen L; Meldal, Morten

    2016-01-11

    Semiconductor nanowires (NWs) are gaining significant importance in various biological applications, such as biosensing and drug delivery. Efficient and controlled immobilization of biomolecules on the NW surface is crucial for many of these applications. Here, we present for the first time the use of the Cu(I) -catalyzed alkyne-azide cycloaddition and its strain-promoted variant for the covalent functionalization of vertical NWs with peptides and proteins. The potential of the approach was demonstrated in two complementary applications of measuring enzyme activity and protein binding, which is of general interest for biological studies. The attachment of a peptide substrate provided NW arrays for the detection of protease activity. In addition, green fluorescent protein was immobilized in a site-specific manner and recognized by antibody binding to demonstrate the proof-of-concept for the use of covalently modified NWs for diagnostic purposes using minute amounts of material. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Electrochemical detection device. [for use in microbiology

    NASA Technical Reports Server (NTRS)

    Young, R. N.; Wilkins, J. R. (Inventor)

    1979-01-01

    A standard pH reference electrode and a platinum cathodic electrode are positioned in a container with suitable nutrient medium for microbial growth plus the sample to be tested. The two electrodes are connected to electronic circuitry including an up/down counter whicn counts up for the first 80 minutes after a test has initiated. Then the potential between the two electrodes is tracked by the electronic circuitry and after there is a change of 10 mv a signal is sent to the up/down counter to cause it to reverse its count. When there is a additional 20 mv change in the potential between the two electrodes another signal is sent to the up/down counter, signalling it to stop. The resulting count on the counter is equal to the length of time for the inoculum to begin the production of measurable amounts of H2 after inoculation.

  1. Microchannel gel electrophoretic separation systems and methods for preparing and using

    DOEpatents

    Herr, Amy; Singh, Anup K; Throckmorton, Daniel J

    2013-09-03

    A micro-analytical platform for performing electrophoresis-based immunoassays was developed by integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device. The microfluidic immunoassays are performed by gel electrophoretic separation and quantifying analyte concentration based upon conventional polyacrylamide gel electrophoresis (PAGE). To retain biological activity of proteins and maintain intact immune complexes, native PAGE conditions were employed. Both direct (non-competitive) and competitive immunoassay formats are demonstrated in microchips for detecting toxins and biomarkers (cytokines, c-reactive protein) in bodily fluids (serum, saliva, oral fluids). Further, a description of gradient gels fabrication is included, in an effort to describe methods we have developed for further optimization of on-chip PAGE immunoassays. The described chip-based PAGE immunoassay method enables immunoassays that are fast (minutes) and require very small amounts of sample (less than a few microliters). Use of microfabricated chips as a platform enables integration, parallel assays, automation and development of portable devices.

  2. Photothermal method of determining calorific properties of coal

    DOEpatents

    Amer, N.M.

    1983-05-16

    Predetermined amounts of heat are generated within a coal sample by directing pump light pulses of predetermined energy content into a small surface region of the sample. A beam of probe light is directed along the sample surface and deflection of the probe beam from thermally induced changes of index of refraction in the fluid medium adjacent the heated region are detected. Deflection amplitude and the phase lag of the deflection, relative to the initiating pump light pulse, are indicative of the calorific value and the porosity of the sample. The method provides rapid, accurate and nondestructive analysis of the heat producing capabilities of coal samples. In the preferred form, sequences of pump light pulses of increasing durations are directed into the sample at each of a series of minute regions situated along a raster scan path enabling detailed analysis of variations of thermal properties at different areas of the sample and at different depths.

  3. How Do Residents Spend Their Shift Time? A Time and Motion Study With a Particular Focus on the Use of Computers

    PubMed Central

    Mamykina, Lena; Vawdrey, David K.; Hripcsak, George

    2016-01-01

    Purpose To understand how much time residents spend using computers as compared with other activities, and what residents use computers for. Method This time and motion study was conducted in June and July 2010 at NewYork-Presbyterian/Columbia University Medical Center with seven residents (first-, second-, and third-year) on the general medicine service. An experienced observer shadowed residents during a single day shift, captured all their activities using an iPad application, and took field notes. The activities were captured using a validated taxonomy of clinical activities, expanded to describe computer-based activities with a greater level of detail. Results Residents spent 364.5 minutes (50.6%) of their shift time using computers, compared with 67.8 minutes (9.4%) interacting with patients. In addition, they spent 292.3 minutes (40.6%) talking with others in person, 186.0 minutes (25.8%) handling paper notes, 79.7 minutes (11.1%) in rounds, 80.0 minutes (11.1%) walking or waiting, and 54.0 minutes (7.5%) talking on the phone. Residents spent 685 minutes (59.6%) multitasking. Computer-based documentation activities amounted to 189.9 minutes (52.1%) of all computer-based activities time, with 128.7 minutes (35.3%) spent writing notes and 27.3 minutes (7.5%) reading notes composed by others. Conclusions The study showed residents spent considerably more time interacting with computers (over 50% of their shift time), than in direct contact with patients (less than 10% of their shift time). Some of this may be due to an increasing reliance on computing systems for access to patient data, further exacerbated by inefficiencies in the design of the electronic health record. PMID:27028026

  4. How Do Residents Spend Their Shift Time? A Time and Motion Study With a Particular Focus on the Use of Computers.

    PubMed

    Mamykina, Lena; Vawdrey, David K; Hripcsak, George

    2016-06-01

    To understand how much time residents spend using computers compared with other activities, and what residents use computers for. This time and motion study was conducted in June and July 2010 at NewYork-Presbyterian/Columbia University Medical Center with seven residents (first-, second-, and third-year) on the general medicine service. An experienced observer shadowed residents during a single day shift, captured all their activities using an iPad application, and took field notes. The activities were captured using a validated taxonomy of clinical activities, expanded to describe computer-based activities with a greater level of detail. Residents spent 364.5 minutes (50.6%) of their shift time using computers, compared with 67.8 minutes (9.4%) interacting with patients. In addition, they spent 292.3 minutes (40.6%) talking with others in person, 186.0 minutes (25.8%) handling paper notes, 79.7 minutes (11.1%) in rounds, 80.0 minutes (11.1%) walking or waiting, and 54.0 minutes (7.5%) talking on the phone. Residents spent 685 minutes (59.6%) multitasking. Computer-based documentation activities amounted to 189.9 minutes (52.1%) of all computer-based activities time, with 128.7 minutes (35.3%) spent writing notes and 27.3 minutes (7.5%) reading notes composed by others. The study showed that residents spent considerably more time interacting with computers (over 50% of their shift time) than in direct contact with patients (less than 10% of their shift time). Some of this may be due to an increasing reliance on computing systems for access to patient data, further exacerbated by inefficiencies in the design of the electronic health record.

  5. Amount of Minutes Played Does Not Contribute to Anterior Cruciate Ligament Injury in National Basketball Association Athletes.

    PubMed

    Okoroha, Kelechi R; Marfo, Kojo; Meta, Fabien; Matar, Robert; Shehab, Ramsy; Thompson, Terry; Moutzouros, Vasilios; Makhni, Eric C

    2017-07-01

    There is limited information on the potential risk factors for sustaining an anterior cruciate ligament (ACL) tear in National Basketball Association (NBA) athletes. This study evaluated 83 NBA players who sustained an ACL injury between 1984 and 2015 to determine the influence of minutes played on injury risk. Minutes played in the injury game, during the season, and over their career were assessed, along with the ability to return to play, player efficiency rating, and playing time after return. Athletes in the NBA played significantly fewer minutes before sustaining an ACL injury (17.1 minutes) than their average minutes per game that season (23.5 minutes; P<.01) or over their career (24.0 minutes; P<.01). One-third of all injuries occurred during the first quarter of the season (preseason to November). There was a 95% rate of return (78 players) to NBA competition the season following ACL injury. Players who were drafted as lottery picks (draft pick 1 to 15) or those who were starters played significantly more minutes the season following injury than those who were not (both P<.01). Players who returned to play had decreased player efficiency ratings when compared with matched controls. This study found that minutes played in a single NBA game did not contribute to the risk of sustaining an ACL injury. Although there was a high rate of return to NBA competition the season following injury, those who were elite athletes played more minutes per game than those who were not. Athletes who returned to play sustained a decrease in player efficiency ratings compared with similar athletes without ACL injury. [Orthopedics. 2017; 40(4):e658-e662.]. Copyright 2017, SLACK Incorporated.

  6. Usefulness of Ultrasonography and Cortical Transit Time to Differentiate Nonobstructive From Obstructive Dilatation in the Management of Prenatally Detected Pelvic Ureteric Junction Like Obstruction.

    PubMed

    Sharma, Gyanendra; Sharma, Anshu

    2017-12-01

    To differentiate a nonobstructive dilatation from an obstructive dilatation in prenatally detected presumed pelvi-ureteric junction obstruction so that intervention can be planned before irreversible damage can occur to the renal unit. From January 2012 to December 2016, all patients with prenatally detected or asymptomatic incidentally detected presumed pelvi-ureteric junction obstruction were evaluated by ultrasonography and renogram. The anteroposterior diameter of the renal pelvis was measured in supine and prone position. Presence of calyceal dilatation in prone position was noted. They were categorized into obstructed, nonobstructed, and equivocal groups based on sonography findings. The differential renal function and the cortical transit time (CTT) was calculated and compared with the sonography groups. Of the 98 patients, 72 were in the obstructed, 18 were in the nonobstructed, and 8 were in the equivocal category. All except 1 in the nonobstructed category had a function of >40% with CTT of <3 minutes. Seventy patients in the obstructed category had a CTT of >3 minutes, whereas 61 had function <40% on initial evaluation. Eleven patients in the obstructed category with an initial function of >40% had CTT of >3 minutes. All of them showed increasing hydronephrosis and deterioration of function during follow-up, necessitating pyeloplasty. All patients in the equivocal group had function >40% and CTT <3 minutes. Ultrasonography along with CTT can help to differentiate nonobstructive from obstructive dilatation. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Detection of Myocardial Ischemia-Reperfusion Injury Using a Fluorescent Near-Infrared Zinc(II)-Dipicolylamine Probe and 99mTc Glucarate

    PubMed Central

    wyffels, Leonie; Gray, Brian D.; Barber, Christy; Pak, Koon Y.; Forbes, Safiyyah; Mattis, Jeffrey A.; Woolfenden, James M.; Liu, Zhonglin

    2012-01-01

    A fluorescent zinc 2,2′-dipicolylamine coordination complex PSVue®794 (probe 1) is known to selectively bind to phosphatidylserine exposed on the surface of apoptotic and necrotic cells. In this study, we investigated the cell death targeting properties of probe 1 in myocardial ischemia-reperfusion injury. A rat heart model of ischemia-reperfusion was used. Probe 1, control dye, or 99mTc glucarate was intravenously injected in rats subjected to 30-minute and 5-minute myocardial ischemia followed by 2-hour reperfusion. At 90 minutes or 20 hours postinjection, myocardial uptake was evaluated ex vivo by fluorescence imaging and autoradiography. Hematoxylin-eosin and cleaved caspase-3 staining was performed on myocardial sections to demonstrate the presence of ischemiareperfusion injury and apoptosis. Selective accumulation of probe 1 could be detected in the area at risk up to 20 hours postinjection. Similar topography and extent of uptake of probe 1 and 99mTc glucarate were observed at 90 minutes postinjection. Histologic analysis demonstrated the presence of necrosis, but only a few apoptotic cells could be detected. Probe 1 selectively accumulates in myocardial ischemia-reperfusion injury and is a promising cell death imaging tool. PMID:22554483

  8. Rainfall and Erosion Response Following a Southern California Wildfire

    NASA Astrophysics Data System (ADS)

    Wohlgemuth, P. M.; Robichaud, P. R.; Brown, R. E.

    2011-12-01

    Wildfire renders landscapes susceptible to flooding and accelerated surface erosion. Consumption of the vegetation canopy and the litter or duff layer removes resistances to the agents of erosion. Moreover, changes in soil properties can restrict infiltration, increasing the effectiveness of the driving forces of rainsplash and surface runoff. However, it is unclear whether surface erosion varies linearly with rainfall amounts and intensities or if thresholds exist beyond which erosion increases in a different trajectory. The Santiago Fire burned over 11000 ha in northeastern Orange County, California in October 2007. The burn area consists of a deeply dissected mountain block underlain by sedimentary and metamorphic rocks that produce erosive soils. Regional erosion and sediment transport is triggered by winter cyclonic storms. Recording raingages were deployed across a vertical gradient within the burned area and silt fences were constructed to monitor hillslope erosion. During the study period initial storms were characterized by moderate rainfall (amounts less than 25 mm with peak 10-minute intensities of less than 10 mm per hr). Surface erosion was concomitantly minor, less than 0.4 Mg per ha. However, an unusual thunderstorm in late May 2008 produced spatially variable rainfall and consequent surface erosion across the study area. The raingage at a lower elevation site measured 41.4 mm of rain for this storm with a peak 10-minute intensity of 81 mm per hr. The silt fences were overtopped, yielding a minimum value of 18.5 Mg per ha. In contrast, the raingage at an upper elevation site recorded 19.6 mm of rain with a peak 10-minute intensity of 50 mm per hr. Surface erosion in the higher elevation sites was negligible (0.1 Mg per ha). Subsequently, individual storms exceeded 100 mm of rainfall but peak 10-minute intensities never approached those of the May thunderstorm. Erosion was moderate (mostly less than 5 Mg per ha), albeit influenced by the presence of regrowing vegetation. We therefore believe that surface erosion in the immediate postfire environment is more related to storm intensity than rainfall amount. Even allowing for site-to-site differences and site changes over the first postfire winter season, it is clear that some threshold in erosion response was crossed at the lower elevation sites during the May 2008 thunderstorm. We suggest that this represents a threshold of peak 10-minute intensity of between 50 and 80 mm per hr.

  9. Identifying and Tracking Solar Photospheric Bright Points Based on Three-dimensional Segmentation Technology

    NASA Astrophysics Data System (ADS)

    Xiong, J. P.; Zhang, A. L.; Ji, K. F.; Feng, S.; Deng, H.; Yang, Y. F.

    2016-01-01

    Photospheric bright points (PBPs) are tiny and short-lived phenomena which can be seen within dark inter-granular lanes. In this paper, we develop a new method to identify and track the PBPs in the three-dimensional data cube. Different from the previous way such as Detection-Before-Tracking, this method is based on the Tracking-While-Detection. Using this method, the whole lifetime of a PBP can be accurately measured while this PBP is possibly separated into several with Laplacian and morphological dilation (LMD) method due to its weak intensity sometimes. With consideration of the G-band PBPs observed by Hinode/SOT (Solar Optical Telescope) for more than two hours, we find that the isolated PBPs have an average lifetime of 3 minutes, and the longest one is up to 27 minutes, which are greater than the values detected by the previous LMD method. Furthermore, we also find that the mean intensity of PBPs is 1.02 times of the mean photospheric intensity, which is less than the values detected by LMD method, and the intensity of PBPs presents a period of oscillation with 2-3 minutes during the whole lifetime.

  10. Multi-instrument observations of sub-minute quasi-periodic pulsations in solar flares

    NASA Astrophysics Data System (ADS)

    Dominique, Marie; Zhukov, Andrei; Dolla, Laurent

    2017-08-01

    Since a decade, quasi-periodic pulsations (QPPs) have been regularly reported to be observed in EUV and SXR during solar flares, while they were previously mostly observed in HXR and radio wavelengths. These new detections can be credited to a new generation of EUV space radiometers (SDO/EVE, PROBA2/LYRA, etc.) that significantly enhanced the instrument performances in terms of signal-to-noise ratio and time resolution. These new instruments allow us to perform statistical analysis of QPPs, which could ultimately help solving the long-debated question of their origin. However, recently, the methods (mainly the way to pre-process data and to account for the noise) used to detect QPPs in those wavelengths were questioned. In this presentation, we will discuss our current understanding of QPPs and the difficulties inherent to their detection. I will particularly address the sub-minute QPPs in the EUV and analyze them in the broader picture of multi-wavelength detection. How do they compare to the pulsations observed in other wavelength ranges? Are sub-minute QPPs and QPPs with longer periods produced by the same processes? What can we learn from the analysis of QPPs? Possible answers to these questions will be presented and discussed.

  11. Improving the desulfurization performance of CaCO3 with sodium humate

    NASA Astrophysics Data System (ADS)

    Feng, Run; Sun, Zhiguo; Zhang, Wenqing; Huang, Hao; Hu, Haihang; Zhang, Li; Xie, Hongyong

    2018-02-01

    The influence of these factors on desulphurization efficiency was studied by changing the amount of calcium carbonate, the concentration of sulfur dioxide, the liquid flow rate of absorbent and the air flow rate, the optimum working condition was determined by the research of limestone-gypsum desulphurization process commonly used in industry. By changing the amount of calcium carbonate, we conclude that the volume of water in the desulfurization efficiency does not increase with the adding amount of calcium carbonate. The optimum conditions were determined : at the condicion of the concentration of 500ppm of sulfur dioxide, 10g calcium carbonate, 150L/h liquid flow and the minimum air flow rate of 6.75m3/h, the highest desulfurization efficiency was close to 100% when sodium humate was not added, but the holding time was only about 5 minutes. After adding 3g of humic acid, the desulfurization efficiency was improved obviously, and the instantaneous efficiency of 100% lasting for about 40 minutes. It can be seen that, calcium carbonate in the addition of humic acid sodium can significantly improve the absorption of calcium carbonate performance of SO2.

  12. [A project to ameliorate nurses working overtime in psychiatry ward].

    PubMed

    Feng, Yuen-Hsiang; Li, Hsiu-Chen; Fang, Mao-So

    2009-12-01

    The authors found nurses working in psychiatry wards were frequently required to work overtime, with average overtime measuring 85 minutes. After analysis, we found main factors leading to overtime to be late new patient admissions, tardy ward inspections by attending physicians, failure to implement workplace regulations, failure by nurses to implement proper shift transfer procedures, and meeting-related delays. This paper proposes an approach by which average overtime for psychiatry ward nurses may be reduced from 85 to 30 minutes. Based on findings, the researchers adjusted the schedule for ward visits by attending physicians, updated and streamlined workplace regulations, ensured administrative procedures were precisely followed, and updated and streamlined standing orders. Average overtime was reduced from 85 to 25 minutes. This research facilitated a reduction in the amount of overtime registered by nurses.

  13. Nano-architectural Alterations in Mucus Layer Fecal Colonocytes in Field Carcinogenesis: Potential for Screening

    PubMed Central

    Roy, Hemant K.; Damania, Dhwanil P.; DelaCruz, Mart; Kunte, Dhananjay P.; Subramanian, Hariharan; Crawford, Susan E.; Tiwari, Ashish K.; Wali, Ramesh K.; Backman, Vadim

    2013-01-01

    Current fecal tests (occult blood, methylation, DNA mutations) target minute amounts of tumor products among a large amount of fecal material and thus have suboptimal performance. Our group has focused on exploiting field carcinogenesis as a modality to amplify the neoplastic signal. Specifically, we have demonstrated that endoscopically normal rectal brushings have striking nano-architectural alterations which are detectable utilizing a novel optical technique, partial wave spectroscopic microscopy (PWS). We therefore wished to translate this approach to a fecal assay. We examined mucus layer fecal colonocytes (MLFCs) at preneoplastic and neoplastic time-points (confirmed with rat colonoscopy) in the azoxymethane (AOM)-treated rat model and conducted PWS analysis to derive the nano-architectural parameter, disorder strength (Ld). We confirmed these results with studies in a genetic model (the Pirc rat). We demonstrated that MLFC appeared microscopically normal, consistent with field carcinogenesis. Ld was elevated at an early time point (5 weeks post-AOM injection, effect size = 0.40, p value = 0.024) and plateaued prior to adenoma formation (10 weeks post-AOM, effect size =0.66, p=0.001), with no dramatic increase once tumors developed. We replicated these data in the pre-neoplastic Pirc rat with an effect size in the MLFC that replicated the rectal brushings (increase versus age-matched controls of 62 versus 74%, respectively). We provide the first demonstration of a biophotonics approach to fecal assay. Furthermore, targeting the nano-architectural changes of field carcinogenesis rather than the detection of tumor products may provide a novel paradigm for colorectal cancer screening. PMID:23983085

  14. Headspace-Solid Phase Microextraction Approach for Dimethylsulfoniopropionate Quantification in Solanum lycopersicum Plants Subjected to Water Stress

    PubMed Central

    Catola, Stefano; Kaidala Ganesha, Srikanta Dani; Calamai, Luca; Loreto, Francesco; Ranieri, Annamaria; Centritto, Mauro

    2016-01-01

    Dimethylsulfoniopropionate (DMSP) and dimethyl sulphide (DMS) are compounds found mainly in marine phytoplankton and in some halophytic plants. DMS is a globally important biogenic volatile in regulating of global sulfur cycle and planetary albedo, whereas DMSP is involved in the maintenance of plant-environment homeostasis. Plants emit minute amounts of DMS compared to marine phytoplankton and there is a need for hypersensitive analytic techniques to enable its quantification in plants. Solid Phase Micro Extraction from Head Space (HS-SPME) is a simple, rapid, solvent-free and cost-effective extraction mode, which can be easily hyphenated with GC-MS for the analysis of volatile organic compounds. Using tomato (Solanum lycopersicum) plants subjected to water stress as a model system, we standardized a sensitive and accurate protocol for detecting and quantifying DMSP pool sizes, and potential DMS emissions, in cryoextracted leaves. The method relies on the determination of DMS free and from DMSP pools before and after the alkaline hydrolysis via Headspace-Solid Phase Micro Extraction-Gas Chromatography-Mass Spectrometry (HS-SPME-GC-MS). We found a significant (2.5 time) increase of DMSP content in water-stressed leaves reflecting clear stress to the photosynthetic apparatus. We hypothesize that increased DMSP, and in turn DMS, in water-stressed leaves are produced by carbon sources other than direct photosynthesis, and function to protect plants either osmotically or as antioxidants. Finally, our results suggest that SPME is a powerful and suitable technique for the detection and quantification of biogenic gasses in trace amounts. PMID:27602039

  15. 75 FR 61784 - Proposed Collection; Comment Request for Review of a Revised Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-06

    ... response time of ten minutes per form reporting a missing check is estimated; the same amount of time is needed to report the missing checks or electronic funds transfer (EFT) payments using the telephone. The...

  16. Blood and exhaled air can be used for biomonitoring of hydrofluorocarbon exposure.

    PubMed

    Ernstgård, Lena; Sjögren, Bengt; Gunnare, Sara; Johanson, Gunnar

    2014-02-10

    Various hydrofluorocarbons (HFCs) have replaced the ozone-depleting chlorofluorocarbons and hydrochlorofluorocarbons during the last decades. The objective of this study was to examine the usefulness of blood and breath for exposure biomonitoring of HFCs. We compared data on blood and exhaled air from a series of experiments where healthy volunteers were exposed to vapors of four commonly used HFCs; 1,1-difluoroethane, 1,1,1-trifluoroethane, 1,1,1,2-tetrafluoroethane, and 1,1,1,3,3-pentafluoropropane. All four HFCs had similar toxicokinetic profiles in blood with a rapid initial increase and an apparent steady-state reached within a few minutes. For all HFCs, the inhalation uptake during exposure was low (less than 6%), most of which was exhaled post-exposure. No metabolism could be detected and only minor amounts were excreted unchanged in urine. The observed time courses in blood and breath were well described by physiologically-based pharmacokinetic (PBPK) modeling. Simulations of 8-h exposures show that the HFC levels in both blood and breath drop rapidly during the first minutes post-exposure, whereafter the decline is considerably slower and mainly reflects washout from fat tissues. We conclude that blood and exhaled air can be used for biological exposure monitoring. Samples should not be taken immediately at the end of shift but rather 20-30 min later. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. The Effect of Endogenous Adenosine on Neuronal Activity in Rats: An FDG PET Study

    PubMed Central

    Paul, Soumen; Zhang, Dali; Mzengeza, Shadreck; Ko, Ji Hyun

    2016-01-01

    ABSTRACT 2–18F‐fluorodeoxy‐D‐glucose (FDG) is a glucose analog that is taken up by cells and phosphorylated. The amount of FDG accumulated by cells is a measure of the rate of glycolysis, which reflects cellular activity. As the levels and actions of the neuromodulator adenosine are dynamically regulated by neuronal activity, this study was designed to test whether endogenous adenosine affects tissue accumulation of FDG as assessed by positron emission tomography (PET) or by postmortem analysis of tissue radioactivity. Rats were given an intraperitoneal injection of the adenosine A1 receptor antagonist 8‐cyclopentyl‐1,3‐dipropyl‐xanthine (DPCPX, 3 mg/kg), the adenosine kinase inhibitor ABT‐702 (3 mg/kg), or vehicle 10 minutes prior to an intravenous injection of FDG (15.4 ± 0.7 MBq per rat). Rats were then subjected to a 15 minute static PET scan. Reconstructed images were normalized to FDG PET template for rats and standard uptake values (SUVs) were calculated. To examine the regional effect of active treatment compared to vehicle, statistical parametric mapping analysis was performed. Whole‐brain FDG uptake was not affected by drug treatment. Significant regional hypometabolism was detected, particularly in cerebellum, of DPCPX‐ and ABT‐702 treated rats, relative to vehicle‐treated rats. Thus, endogenous adenosine can affect FDG accumulation although this effect is modest in quiescent rats. PMID:27082948

  18. Comparative study of efficacy, rapidity of detection, and cost-effectiveness of potassium hydroxide, calcofluor white, and Chicago sky blue stains in the diagnosis of dermatophytoses.

    PubMed

    Prakash, R; Prashanth, Hosakere Veerappa; Ragunatha, Shivanna; Kapoor, Meenakshi; Anitha, T K; Krishnamurthy, Veena

    2016-04-01

    The diagnosis of superficial mycosis such as dermatophytosis is often done clinically. However, in difficult cases, a rapid test with high sensitivity and specificity helps in the immediate confirmation and administration of treatment. The efficacy, rapidity of detection, and cost-effectiveness of KOH preparation, calcofluor white (CW) stain, and Chicago sky blue (CSB) stain in the identification of fungal elements were assessed in patients with dermatophytoses attending the dermatology clinic of a tertiary care hospital. All three tests were performed on each sample collected from 73 patients according to standard procedure. The slides were examined after 5 and 30 minutes in × 10 and × 40 magnifications. The sensitivity and specificity of CW and CSB at 5 and 30 minutes were calculated using KOH preparation as the standard test. CSB stain showed highest positivity (94.5%) within 5 minutes when compared to KOH (75.3%) and CW (83.5%). After 30 minutes, positivity increased in KOH (84.9%) and CW stains (89%), but it remained the same in CSB stain. Both CW and CSB stains when compared to 10% KOH are equally sensitive (100%), but CW was more specific (72.7%), particularly at 30 minutes. When cost of performing tests on 100 specimens is considered, KOH, CW, and CSB stains cost Rs 5, 100, and 15, respectively. CSB stain is a better stain for rapid diagnosis of dermatophytoses because of ease of performance, rapidity of detection, better appreciation of morphology of fungal elements, and cost effectiveness. © 2016 The International Society of Dermatology.

  19. [The Misgav-Ladach method for cesarean section compared to the Pfannenstiel technique].

    PubMed

    Studziński, Zbigniew

    2002-08-01

    The aim of the study was to evaluate the outcome of two different methods of cesarean section. To determine whether the Misgav-Ladach caesarean technique can offer benefits when compared with conventional Pfannenstiel caesarean section technique. This study describes operative details and the postoperative course of 110 patients who underwent caesarean section in May 2000 to December 2000 in Department of Gynecology and Obstetrics in Regional Hospital in Slupsk, Poland. One group (50 women) was operated with the Misgav-Ladach method for caesarean section and the other group (60 women) with Pfannenstiel method. Operating time was significantly different between the two methods, with an average of 20.2 minutes with the Misgav-Ladach method and 47.3 minutes with the Pfannenstiel method (p < 0.001). Time of child delivery was with average 1.1 minutes with the Misgav-Ladach method and 3.8 minutes with the Pfannenstiel method (p < 0.001). The amount of blood loss different significantly, with 336 ml and 483 ml respectively (p < 0.001). No significant difference was found in Apgar scores. No difference was found in overall postoperative complications, wound infection, febrile illness, febrile morbidity, wound dehiscence affected by the new technique. Significantly less suture material was used during Misgav-Ladach caesarean section compared to Pfannenstiel technique (p < 0.001). The Misgav-Ladach method of caesarean section has advantages over the Pfannenstiel technique by being significantly quicker to perform, with the reduced amounts of bleeding and suture material. The women were satisfied with the appearance of their scars. In this study no negative effects of the new operation technique were discovered.

  20. A sarabande of tropical fruit proteomics: Avocado, banana, and mango.

    PubMed

    Righetti, Pier Giorgio; Esteve, Clara; D'Amato, Alfonsina; Fasoli, Elisa; Luisa Marina, María; Concepción García, María

    2015-05-01

    The present review highlights the progress made in plant proteomics via the introduction of combinatorial peptide ligand libraries (CPLL) for detecting low-abundance species. Thanks to a novel approach to the CPLL methodology, namely, that of performing the capture both under native and denaturing conditions, identifying plant species in the order of thousands, rather than hundreds, is now possible. We report here data on a trio of tropical fruits, namely, banana, avocado, and mango. The first two are classified as "recalcitrant" tissues since minute amounts of proteins (in the order of 1%) are embedded on a very large matrix of plant-specific material (e.g., polysaccharides and other plant polymers). Yet, even under these adverse conditions we could report, in a single sweep, from 1000 to 3000 unique gene products. In the case of mango the investigation has been extended to the peel too, since this skin is popularly used to flavor dishes in Far East cuisine. Even in this tough peel 330 proteins could be identified, whereas in soft peels, such as in lemons, one thousand unique species could be detected. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Noncontact measurement of emotional and physiological changes in heart rate from a webcam.

    PubMed

    Madan, Christopher R; Harrison, Tyler; Mathewson, Kyle E

    2018-04-01

    Heart rate, measured in beats per minute, can be used as an index of an individual's physiological state. Each time the heart beats, blood is expelled and travels through the body. This blood flow can be detected in the face using a standard webcam that is able to pick up subtle changes in color that cannot be seen by the naked eye. Due to the light absorption spectrum of blood, we are able to detect differences in the amount of light absorbed by the blood traveling just below the skin (i.e., photoplethysmography). By modulating emotional and physiological stress-that is, viewing arousing images and sitting versus standing, respectively-to elicit changes in heart rate, we explored the feasibility of using a webcam as a psychophysiological measurement of autonomic activity. We found a high level of agreement between established physiological measures, electrocardiogram, and blood pulse oximetry, and heart rate estimates obtained from the webcam. We thus suggest webcams can be used as a noninvasive and readily available method for measuring psychophysiological changes, easily integrated into existing stimulus presentation software and hardware setups. © 2017 Society for Psychophysiological Research.

  2. Diagnostic Sensitivity and Specificity of Dark Adaptometry for Detection of Age-Related Macular Degeneration

    PubMed Central

    Jackson, Gregory R.; Scott, Ingrid U.; Kim, Ivana K.; Quillen, David A.; Iannaccone, Alessandro; Edwards, John G.

    2014-01-01

    Purpose. Difficulty with night vision is a common complaint of patients with age-related macular degeneration (AMD). Consistent with this complaint, dark adaptation (DA) is substantially impaired in these patients. Because of the severity of the deficit, measurement of DA has been suggested as a means for the diagnosis of AMD. Previous methods for measurement of DA were time intensive (>30 minutes), which made them unsuitable for clinical use. This study evaluated a rapid DA test (≤6.5 minutes) for the detection of AMD. Methods. Dark adaptation was measured by using the AdaptDx dark adaptometer in two groups: subjects with normal retinal health and subjects with AMD. Subjects were assigned to their group by clinical examination and grading of fundus photographs. Subjects were classified as having DA consistent with normal retinal health (rod intercept ≤ 6.5 minutes) or having dark adaptation consistent with AMD (rod intercept > 6.5 minutes). Results. The eligible sample for analysis included 21 normal adults and 127 AMD patients. The rapid test was found to have a diagnostic sensitivity of 90.6% (P < 0.001) and specificity of 90.5% (P < 0.027). Thus, abnormal DA was detected in 115 of 127 AMD patients, and normal DA was found in 19 of 21 normal adults. Conclusions. The high diagnostic sensitivity and specificity compared favorably to long-duration research methods for the measurement of DA, and slit lamp biomicroscopy performed by a retina specialist. These results suggest that a rapid DA test is useful for the detection of AMD. PMID:24550363

  3. The effect of differences in time to detection of circulating microbubbles on the risk of decompression sickness

    NASA Technical Reports Server (NTRS)

    Kumar, K. V.; Gilbert, J. H.; Powell, M. R.; Waligora, J. M.

    1992-01-01

    Circulating microbubbles (CMB) are frequently detected prior to the appearance of symptoms of Decompression Sickness (DCS). It is difficult to analyze the effect of CMB on symptoms due to differences in the time to detection of CMB. This paper uses survival analysis models to evaluate the risk of symptoms in the presence of CMB. Methods: Information on 81 exposures to an altitude of 6,400 m (6.5 psi) for a period of three hours, with simulated extravehicular activities, was examined. The presence or absence of CMB was included as a time dependent covariate of the Cox proportional hazards regression model. Using this technique, the subgroup of exposures with CMB was analyzed further. Mean (S.D.) time in minutes to onset of CMB and symptoms were 125 (63) and 165 (33) respectively, following the three hours exposure. The risk of symptoms (17/81) increased 14 times in the presence of CMB, after controlling for variations in time to detection of CMB. Further, the risk was lower when time to detection of CMB was greater than 60 minutes (risk ratio = 0.96; 95 percent confidence intervals = 0.94 - 0.99 0.99 P less than 0.01) compared to CMB before 60 minutes at altitude. Conclusions: Survival analysis showed that individual risk of DCS changes significantly due to variations in time to detection of CMB. This information is important in evaluating the risk of DCS in the presence of CMB.

  4. Why Cannot Suction Drains Prevent Postoperative Spinal Epidural Hematoma?

    PubMed Central

    Ahn, Dong Ki; Kim, Jin Woo; Yi, Seong Min

    2016-01-01

    Background Postoperative spinal epidural hematoma (POSEH) is different from spontaneous or post-spinal procedure hematoma because of the application of suction drains. However, it appeared that suction drains were not effective for prevention of POSEH in previous studies. The purpose of this study was to test our hypothesis that POSEH can be caused by hypercoagulability. Methods This was an experimental study. One hundred fifty milliliters of blood was donated from each of the 12 consecutive patients who underwent spine surgery and infused into 3 saline bags of 50 mL each. One of the 3 bags in each set contained 5,000 units of thrombin. All of them were connected to 120 ± 30 mmHg vacuum suctions: drainage was started 8 minutes after connection to the vacuum system for 12 normal blood bags (BV8) and 12 thrombin-containing blood bags (TBV8) and 15 minutes after connection for the remaining 12 normal blood bags (BV15). The amount of initial and remaining hematoma at 20 minutes, 120 minutes, and 24 hours after vacuum application were measured by their weight (g). The primary endpoint was the difference between BV8 and TBV8. The secondary end point was the difference between BV8 and BV15. Results The remaining hematoma in TBV8 was significantly greater than that in BV8 at all measurement points: 46.3 ± 12.4 vs. 17.0 ± 1.3 (p = 0.000) at 20 minutes; 33.0 ± 8.2 vs. 16.3 ± 1.2 (p = 0.000) at 120 minutes; and 26.1 ± 4.0 vs. 15.8 ± 1.6 (p = 0.000) at 24 hours after vacuum application. The remaining hematoma of BV15 was significantly greater than that of BV8 at all measurement points: 30.0 ± 12.0 vs. 17.0 ± 1.3 (p = 0.002) at 20 minutes; 24.2 ± 7.6 vs. 16.3 ± 1.2 at 120 minutes (p = 0.002); and 22.2 ± 6.6 vs. 15.8 ± 1.6 (p = 0.004) at 24 hours after vacuum application. Conclusions With a suction drain in place, the amount of remaining hematoma could be affected by coagulability. Thrombin-containing local hemostatics and the length of time elapsed before the commencement of suction resulted in hypercoagulability, indicating these two factors could be causes of POSEH. PMID:27904723

  5. Electrochemical sensing of sulphur dioxide: a comparison using dodecanethiol and citrate capped gold nanoclusters.

    PubMed

    Sathe, Bhaskar R; Risbud, Mandar S; Mulla, Imtiaz S; Pillai, Vijayamohanan K

    2008-06-01

    A comparison of cyclic voltammograms of dodecanethiol (DDT) capped Au nanoclusters (5.0 0.5 nm) and trisodium citrate (Cit) capped Au nanoclusters (approximately 10-15 nm) modified glassy carbon electrode shows a dramatic variation in the current when exposed to a small amount of sulphur dioxide. This is explained using the electrocatalytic properties of Au nanoclusters towards the oxidation of SO2, thus facilitating the fabrication of electrochemical sensors for the detection of SO2. The intrinsic redox changes observed for gold nanocluster-modified glassy carbon electrodes disappear on passing SO2, despite a dramatic current increase, which indeed scales up with the amount of dissolved SO2. Interestingly, a complete rejuvenation of the redox behavior of gold is also observed on subsequent removal of SO2 from the solution by passing pure nitrogen for 15 minutes. Further, these nanoclusters when characterized with X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR) after SO2 passage reveal a variety of SO2 adsorption modes on gold surface. XP spectra also show a shift of 1.03 eV towards higher binding energy indicating a strong adsorption of SO2 gas, while FTIR gives conclusive evidence for the interaction of SO2 with gold nanoparticles.

  6. U.S. Air Forces Aerial Spray Mission: Should the Department of Defense Continue to Operate this Weapon of Mass Dispersion

    DTIC Science & Technology

    2015-12-01

    pesticide application over farm fields to produce a better crop.2 On 3 August 1921 in a joint effort between the U.S. Army Signal Corps in Dayton, Ohio... pesticide dissemination because of the relatively small amount of product needed to spray for nuisance insects over a vast area. The ULV system is... pesticide per minute. Applications that require massive amounts of liquid herbicide to neutralize cheatgrass and other fire-prone, invasive vegetation on

  7. In-vivo detection of bleeding simulated in a Peritoneal dialysis model using a hemiarray EIT configuration

    NASA Astrophysics Data System (ADS)

    Tucker, Aaron S.; Ross, Edward; Paugh-Miller, Jennifer; Sadleir, Rosalind J.

    2010-04-01

    A new method to image and quantify intra-abdominal hemorrhage (IAH) using electrical impedance tomography (EIT) was tested. We proposed an electrode hemi-array placed exclusively on the anterior abdomen to monitor a supine patient for IAH without complicating concurrent traumatic injuries. Peritoneal dialysis (PD) was used as a model for IAH to assess the in vivo performance of the hemi-array. Using the EPack 2 data acquisition system, EIT measurements were recorded before, during, and after the administration of dialysate. Simultaneously, the amount of dialysate was recorded, synchronous to the EIT measurements, to be used as a control. Tomographic images of impedance change were reconstructed using a weighted, sensitivity-based method and then post-processed to obtain a quantitative estimate of the total dialysate administered. Our preliminary study included two subjects, one male and one female, each participating for two sessions, spaced about six months apart. Data collected from these sessions indicate that with a realized in vivo SNR of about 35dB the EPack 2 can detect accumulations larger than about 100mL with a quantification uncertainty of about +/- 50mL. Using these data we have developed new algorithms that can automatically detect the onset of bleeding in less than two minutes. This method shows promise for automated detection of other pathologies, e.g. ascites, and is adaptable for use on other anatomy including the skull, and pelvis.

  8. Unambiguous detection of speciated stabilized Criegee intermediates via gas phase derivatization followed by detection using mass spectrometry

    NASA Astrophysics Data System (ADS)

    Breitenlechner, Martin; Zaytsev, Alexander; Kroll, Jesse; Hansel, Armin; Keutsch, Frank N.

    2017-04-01

    Ozonolysis of unsaturated volatile organic compounds proceeds via formation of primary ozonides followed by decomposition leading to Criegee intermediates (CI). Their internal energy, buffer gas density and temperature and number of internal degrees of freedom affect their unimolecular lifetime. Stabilized CI (sCI) have sufficient long lifetimes that their fate is determined by trace gases present in the atmosphere. Due to the lack of reliable measurement techniques - especially for larger CI - their role in atmospheric chemistry still remains largely ambiguous. We present results from an effort trying to close this observational gap by utilizing gas phase derivatization of sCIs followed by detection of the formed complexes with chemical ionization mass spectrometry. Our results suggest that the reactions of, e.g., Hexafluoroacetone (HFA) with a number of sCIs (ranging from CIs containing 2 to 10 carbons) are sufficiently fast so that complete conversion can be achieved when adding HFA at ppm levels - largely independent from the exact reaction rate and the amount of HFA introduced beyond that threshold. Using proton transfer reaction time-of-flight mass spectrometry (PTR-ToF), the protonated covalently bound complexes show little to none fragmentation, have unique mass defects and can therefore be clearly separated from other protonated species. We further highlight both analytical and technical challenges accompanied with the implementation of a detection scheme along this route, comprising a broad range of sCIs present at typically minute atmospheric concentrations.

  9. Detection of Orthopoxvirus DNA by Real-Time PCR and Identification of Variola Virus DNA by Melting Analysis

    PubMed Central

    Nitsche, Andreas; Ellerbrok, Heinz; Pauli, Georg

    2004-01-01

    Although variola virus was eradicated by the World Health Organization vaccination program in the 1970s, the diagnosis of smallpox infection has attracted great interest in the context of a possible deliberate release of variola virus in bioterrorist attacks. Obviously, fast and reliable diagnostic tools are required to detect variola virus and to distinguish it from orthopoxviruses that have identical morphological characteristics, including vaccinia virus. The advent of real-time PCR for the clinical diagnosis of viral infections has facilitated the detection of minute amounts of viral nucleic acids in a fast, safe, and precise manner, including the option to quantify and to genotype the target reliably. In this study a complete set of four hybridization probe-based real-time PCR assays for the specific detection of orthopoxvirus DNA is presented. Melting analysis following PCR enables the identification of variola virus by the PCR product's characteristic melting temperature, permitting the discrimination of variola virus from other orthopoxviruses. In addition, an assay for the specific amplification of variola virus DNA is presented. All assays can be performed simultaneously in the same cycler, and results of a PCR run are obtained in less than 1 h. The application of more than one assay for the same organism significantly contributes to the diagnostic reliability, reducing the risk of false-negative results due to unknown sequence variations. In conclusion, the assays presented will improve the speed and reliability of orthopoxvirus diagnostics and variola virus identification. PMID:15004077

  10. L-Arginine Modulates Intestinal Inflammation in Rats Submitted to Mesenteric Ischemia-Reperfusion Injury.

    PubMed

    Taha, M O; de Oliveira, J V; Dias Borges, M; de Lucca Melo, F; Gualtieri, F G; E Silva Aidar, A L; Pacheco, R L; de Melo Alexandre E Silva, T; Klajner, R K; Iuamoto, L R; Munhoz Torres, L; Morais Mendes de Paula, B J; de Campos, K; Oliveira-Junior, I S; Fagundes, D J

    2016-03-01

    The goal of this study was to investigate whether exogenous offer of L-arginine (LARG) modulates the gene expression of intestinal dysfunction caused by ischemia and reperfusion. Eighteen Wistar-EPM1 male rats (250-300 g) were anesthetized and subjected to laparotomy. The superior mesenteric vessels were exposed, and the rats were randomized into 3 groups (n = 6): the control group (CG), with no superior mesenteric artery interruption; the ischemia/reperfusion group (IRG), with 60 minutes of ischemia and 120 minutes of reperfusion and saline injections; and the L-arginine group (IRG + LARG), with L-arginine injected in the femoral vein 5 minutes before ischemia, 5 minutes after reperfusion, and after 55 minutes of reperfusion. The total RNA was extracted and purified from samples of the small intestine. The concentration of each total RNA sample was determined by using spectrophotometry. The first-strand complementary DNA (cDNA) was synthesized in equal amounts of cDNA and the Master Mix SYBR Green qPCR Mastermix (SABiosciences, a Qiagen Company, Frederick, Md). Amounts of cDNA and Master Mix SYBR Green qPCR Mastermix were distributed to each well of the polymerase chain reaction microarray plate containing the predispensed gene-specific primer sets for Bax and Bcl2. Each sample was evaluated in triplicate, and the Student t test was applied to validate the homogeneity of each gene expression reaction (P < .05). The gene expression of Bax in IRG (+1.48) was significantly higher than in IRG-LARG (+9.69); the expression of Bcl2L1 in IRG (+1.01) was significantly higher than IRG-LARG (+22.89). The apoptotic cell pathway of 2 protagonists showed that LARG improves the gene expression of anti-apoptotic Bcl2l1 (Bcl2-like 1) more than the pro-apoptotic Bax (Bcl2-associated X protein). Copyright © 2016. Published by Elsevier Inc.

  11. A new metric for detecting change in slowly evolving brain tumors: validation in meningioma patients.

    PubMed

    Pohl, Kilian M; Konukoglu, Ender; Novellas, Sebastian; Ayache, Nicholas; Fedorov, Andriy; Talos, Ion-Florin; Golby, Alexandra; Wells, William M; Kikinis, Ron; Black, Peter M

    2011-03-01

    Change detection is a critical component in the diagnosis and monitoring of many slowly evolving pathologies. This article describes a semiautomatic monitoring approach using longitudinal medical images. We test the method on brain scans of patients with meningioma, which experts have found difficult to monitor because the tumor evolution is very slow and may be obscured by artifacts related to image acquisition. We describe a semiautomatic procedure targeted toward identifying difficult-to-detect changes in brain tumor imaging. The tool combines input from a medical expert with state-of-the-art technology. The software is easy to calibrate and, in less than 5 minutes, returns the total volume of tumor change in mm. We test the method on postgadolinium, T1-weighted magnetic resonance images of 10 patients with meningioma and compare our results with experts' findings. We also perform benchmark testing with synthetic data. Our experiments indicated that experts' visual inspections are not sensitive enough to detect subtle growth. Measurements based on experts' manual segmentations were highly accurate but also labor intensive. The accuracy of our approach was comparable to the experts' results. However, our approach required far less user input and generated more consistent measurements. The sensitivity of experts' visual inspection is often too low to detect subtle growth of meningiomas from longitudinal scans. Measurements based on experts' segmentation are highly accurate but generally too labor intensive for standard clinical settings. We described an alternative metric that provides accurate and robust measurements of subtle tumor changes while requiring a minimal amount of user input.

  12. Influence of rainfall microstructure on rainfall interception

    NASA Astrophysics Data System (ADS)

    Zabret, Katarina; Rakovec, Jože; Mikoš, Matjaž; Šraj, Mojca

    2016-04-01

    Rainfall interception is part of the hydrological cycle. Precipitation, which hits vegetation, is retained on the leaves and branches, from which it eventually evaporates into the atmosphere (interception) or reaches the ground by dripping from the canopy, falling through the gaps (throughfall) and running down the stems (stemflow). The process is influenced by various meteorological and vegetation parameters. Often neglected meteorological parameter influencing rainfall interception is also rainfall microstructure. Rain is a discrete process consisting of various numbers of individual raindrops with different sizes and velocities. This properties describe rainfall microstructure which is often neglected in hydrological analysis and replaced with rainfall intensity. Throughfall, stemflow and rainfall microstructure have been measured since the beginning of the year 2014 under two tree species (Betula pendula and Pinus nigra) on a study plot in Ljubljana, Slovenia. The preliminary analysis of the influence of rainfall microstructure on rainfall interception has been conducted using three events with different characteristics measured in May 2014. Event A is quite short with low rainfall amount and moderate rainfall intensity, whereas events B and C have similar length but low and high intensities, respectively. Event A was observed on the 1st of May 2014. It was 22 minutes long and delivered 1.2 mm of rainfall. The average rainfall intensity was equal to 3.27 mm/h. The event consisted of 1,350 rain drops with average diameter of 1.517 mm and average velocity of 5.110 m/s. Both Betula pendula and Pinus nigra intercepted similar amount of rainfall, 68 % and 69 %, respectively. Event B was observed in the night from the 7th to 8th of May 2014, it was 16 hours and 18 minutes long, and delivered 4.2 mm of rainfall with average intensity of 0.97 mm/h. There were 39,108 raindrops detected with average diameter of 0.858 mm and average velocity of 3.855 m/s. Betula pendula (23 %) has intercepted significantly less rainfall than Pinus nigra (85%). Event C was also observed in the night time between 11th and 12th of May 2014, it lasted 4 hours and 12 minutes and delivered 34.6 mm of rainfall with an average intensity equal to 8.24 mm/h. During the event 147,236 raindrops with average diameter of 1.020 mm and average velocity of 4.078 m/s were detected. Betula pendula has intercepted only 6 % of rainfall whereas Pinus nigra intercepted majority of rainfall, namely 85 %. In case of B. pendula rainfall interception is increasing with higher velocity whereas it is lower for medium diameters than for smaller or larger diameters. Rainfall interception under P. nigra is decreasing with higher velocities and behaving similar as under B. pendula for different diameters but with less obvious difference between diameter classes. We will continue with the measurements and further analysis of several rainfall events will be prepared.

  13. 76 FR 12999 - Submission for OMB Review; Comment Request for Review of a Revised Information Collection: (OMB...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ...,600 are reported by telephone. A response time of ten minutes per form reporting a missing check is estimated; the same amount of time is needed to report the missing checks or electronic funds transfer (EFT...

  14. Experimental investigation of amount of nano-Al2O3 on mechanical properties of Al-based nano-composites fabricated by powder metallurgy (PM)

    NASA Astrophysics Data System (ADS)

    Razzaqi, A.; Liaghat, Gh.; Razmkhah, O.

    2017-10-01

    In this paper, mechanical properties of Aluminum (Al) matrix nano-composites, fabricated by Powder Metallurgy (PM) method, has been investigated. Alumina (Al2O3) nano particles were added in amounts of 0, 2.5, 5, 7.5 and 10 weight percentages (wt%). For this purpose, Al powder (particle size: 20 µm) and nano-Al2O3 (particle size: 20 nm) in various weight percentages were mixed and milled in a blade mixer for 15 minutes in 1500 rpm. Then, the obtained mixture, compacted by means of a two piece die and uniaxial cold press of about 600 MPa and cold iso-static press (CIP), required for different tests. After that, the samples sintered in 600°C for 90 minutes. Compression and three-point bending tests performed on samples and the results, led us to obtain the optimized particle size for achieving best mechanical properties.

  15. Cryotherapy induces an increase in muscle stiffness.

    PubMed

    Point, M; Guilhem, G; Hug, F; Nordez, A; Frey, A; Lacourpaille, L

    2018-01-01

    Although cold application (ie, cryotherapy) may be useful to treat sports injuries and to prevent muscle damage, it is unclear whether it has adverse effects on muscle mechanical properties. This study aimed to determine the effect of air-pulsed cryotherapy on muscle stiffness estimated using ultrasound shear wave elastography. Myoelectrical activity, ankle passive torque, shear modulus (an index of stiffness), and muscle temperature of the gastrocnemius medialis were measured before, during an air-pulsed cryotherapy (-30°C) treatment of four sets of 4 minutes with 1-minute recovery in between and during a 40 minutes postcryotherapy period. Muscle temperature significantly decreased after the second set of treatment (10 minutes: 32.3±2.5°C; P<.001), peaked at 29 minutes (27.9±2.2°C; P<.001) and remained below baseline values at 60 minutes (29.5±2.0°C; P<.001). Shear modulus increased by +11.5±11.8% after the second set (10 minutes; P=.011), peaked at 30 minutes (+34.7±42.6%; P<.001), and remained elevated until the end of the post-treatment period (+25.4±17.1%; P<.001). These findings provide evidence that cryotherapy induces an increase in muscle stiffness. This acute change in muscle mechanical properties may lower the amount of stretch that the muscle tissue is able to sustain without subsequent injury. This should be considered when using cryotherapy in athletic practice. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Automatically Inspecting Thin Ceramics For Pinholes

    NASA Technical Reports Server (NTRS)

    Honaker, James R.

    1988-01-01

    Proposed apparatus for inspecting prefired ceramic materials detects minute flaws that might escape ordinary visual inspections. Method detects flaws and marks locations. Intended for such thin ceramic parts as insulation in capacitors and some radio-frequency filters.

  17. Effect of aminocaproic acid on clot strength and clot lysis of canine blood determined by use of an in vitro model of hyperfibrinolysis.

    PubMed

    Brown, Jamie C; Brainard, Benjamin M; Fletcher, Daniel J; Nie, Ben; Arnold, Robert D; Schmiedt, Chad W

    2016-11-01

    OBJECTIVE To determine pharmacodynamic and pharmacokinetic profiles of aminocaproic acid (ACA) by use of a thromboelastography (TEG)-based in vitro model of hyperfibrinolysis and high-performance liquid chromatography-mass spectrometry. ANIMALS 5 healthy adult dogs. PROCEDURES A single dose of injectable ACA (20, 50, or 100 mg/kg) or an ACA tablet (approximately 100 mg/kg) was administered orally. Blood samples were collected at 0, 15, 30, 45, 60, 90, 120, and 240 minutes after ACA administration for pharmacokinetic analysis. Samples were obtained at 0, 60, and 240 minutes for pharmacodynamic analysis by use of a TEG model of hyperfibrinolysis. RESULTS No adverse effects were detected. In the hyperfibrinolysis model, after all doses, a significantly higher TEG maximum amplitude (clot strength), compared with baseline, was detected at 60 and 240 minutes. Additionally, the percentage of fibrinolysis was reduced from the baseline value at 60 and 240 minutes, with the greatest reduction at 60 minutes. At 240 minutes, there was significantly less fibrinolysis for the 100 mg/kg dose than the 20 mg/kg dose. Maximum plasma ACA concentration was dose dependent. There was no significant difference in pharmacokinetic parameters between 100 mg/kg formulations. CONCLUSIONS AND CLINICAL RELEVANCE In an in vitro model of hyperfibrinolysis, ACA inhibited fibrinolysis at all doses tested. At 240 minutes after administration, the 100 mg/kg dose inhibited fibrinolysis more effectively than did the 20 mg/kg dose. Thus, ACA may be useful for in vivo prevention of fibrinolysis in dogs. IMPACT FOR HUMAN MEDICINE These data may improve research models of hyperfibrinolytic diseases.

  18. Orthopedic resident work-shift analysis: are we making the best use of resident work hours?

    PubMed

    Hamid, Kamran S; Nwachukwu, Benedict U; Hsu, Eugene; Edgerton, Colston A; Hobson, David R; Lang, Jason E

    2014-01-01

    Surgery programs have been tasked to meet rising demands in patient surgical care while simultaneously providing adequate resident training in the midst of increasing resident work-hour restrictions. The purpose of this study was to quantify orthopedic surgery resident workflow and identify areas needing improved resident efficiency. We hypothesize that residents spend a disproportionate amount of time involved in activities that do not relate directly to patient care or maximize resident education. We observed 4 orthopedic surgery residents on the orthopedic consult service at a major tertiary care center for 72 consecutive hours (6 consecutive shifts). We collected minute-by-minute data using predefined work-task criteria: direct new patient contact, direct existing patient contact, communications with other providers, documentation/administrative time, transit time, and basic human needs. A seventh category comprised remaining less-productive work was termed as standby. In a 720-minute shift, residents spent on an average: 191 minutes (26.5%) performing documentation/administrative duties, 167.0 minutes (23.2%) in direct contact with new patient consults, 129.6 minutes (17.1%) in communication with other providers regarding patients, 116.2 (16.1%) minutes in standby, 63.7 minutes (8.8%) in transit, 32.6 minutes (4.5%) with existing patients, and 20 minutes (2.7%) attending to basic human needs. Residents performed an additional 130 minutes of administrative work off duty. Secondary analysis revealed residents were more likely to perform administrative work rather than directly interact with existing patients (p = 0.006) or attend to basic human needs (p = 0.003). Orthopedic surgery residents spend a large proportion of their time performing documentation/administrative-type work and their workday can be operationally optimized to minimize nonvalue-adding tasks. Formal workflow analysis may aid program directors in systematic process improvements to better align resident skills with tasks. III. Published by Elsevier Inc.

  19. The effects of smart phone gaming duration on muscle activation and spinal posture: Pilot study.

    PubMed

    Park, Joo-Hee; Kang, Sun-Young; Lee, Sa-Gyeom; Jeon, Hye-Seon

    2017-08-01

    This study investigates changes in the posture angles of the neck and trunk, together with changes in the muscle activation of users, at the start of and at 5, 10, and 15 minutes of smartphone use. Eighteen males participated in this study. Surface electromyography (EMG) and a digital camera were used to measure the muscle activation and angular changes of the neck and trunk of participants during smartphone use for a period of 16 minutes. Neck and trunk flexion significantly increased at 5, 10, and 15 minutes (p < 0.05) in comparison with the neck and trunk flexion of participants at the start of smartphone usage. The EMG activation and 10th%amplitude probability distribution function (APDF) values of the bilateral cervical erector spinae at 5-6, 10-11, and 15-16 minutes of usage (p < 0.05) were also significantly greater than at the start of usage. The EMG activation of the bilateral thoracic erector spinae and lower trapezius was significantly decreased at 5-6, 10-11, and 15-16 minutes of usage (p < 0.05). Smartphone use induced more flexed posture on the neck and trunk than other visual display terminal (VDT) work. Smartphone use also changed posture and muscle activation within a relatively short amount of time, just 5 minutes. Pain after 16 minutes of smartphone use was also observed. Thus, clinicians should consider the influences of smartphone use in posture and muscle activity in evaluation, intervention, and prevention of neck and trunk conditions.

  20. Fluorescein Diacetate Microplate Assay in Cell Viability Detection.

    PubMed

    Chen, Xi; Yang, Xiu-Ying; Fang, Lian-Hua; DU, Guan-Hua

    2016-12-20

    Objective To investigate the application of the fluorescein diacetate (FDA) microplate assay in cell viability detection. Methods Cells were seeded in a 96-well culture plate until detection. After incubated with FDA,the plate was detected by fluorescence microplate analyzer. The effects of FDA incubation duration,concentration,and other factors on the assay's accuracy and stability were assessed. We also compared the results of FDA with methyl thiazolyl(MTT) in terms of cell numbers and H 2 O 2 injury. Results Within 0-30 minutes,the fluorescence-cell number coefficient of FDA assay increased with duration and reached 0.99 in 27-30 minutes. The optimum concentration of final FDA in this study was 10-30 μg/ml. On cell viability detection,the result of FDA method was equivalent to MTT method. As to H 2 O 2 injury assay,the sensitivity of FDA method was superior to MTT on the higher concentration H 2 O 2 treatment due to a relative shorter duration for detection. Conclusion As a stable and reliable method,FDA is feasible for cell variability detection under varied conditions.

  1. Training dogs to detect Triacetone Triperoxide (TATP)

    NASA Astrophysics Data System (ADS)

    Oxley, Jimmie C.; Smith, James L.; Moran, Jesse; Nelson, Ken; Utley, William E.

    2004-09-01

    Dogs have been used successfully to detect drugs and conventional high explosives. The world-wide rise in terrorist activities has placed emphasis on the detection of non-conventional explosive materials such as the multi-functional peroxides, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD). This study demonstrates that dogs can detect both solid TATP and TATP adsorbed to cotton balls. An effective procedure to train dogs to detect TATP using cotton balls permeated with TATP vapor is provided. The various trials showed that dogs were capable of detecting as little as 200 μg of TATP adsorbed to a one gram cotton ball under a variety of circumstances. However, since TATP vaporizes rapidly at room temperature, significant depletion of TATP from cotton balls can occur in as little as 20 minutes, hampering the ability of the dogs to detect it. The TATP depleted cotton ball can be refreshed by returning it to a sealed container with TATP residue for about 20 minutes. A presumed decomposition product of TATP, acetone, cannot be used in place of TATP to train dogs.

  2. Detection ratios of riparian songbirds

    Treesearch

    Susan L. Earnst; Jeannie Heltzel

    2005-01-01

    This paper presents preliminary results from the first year of a two-year study designed to evaluate bias in a typical songbird survey by examining differences in detection ratios among species, cover types, and time of the season. Detection ratios, calculated as number of individuals detected during a 15-25 minute fixed-width transect survey divided by the number of...

  3. Detecting Airborne Mercury by Use of Palladium Chloride

    NASA Technical Reports Server (NTRS)

    Ryan, Margaret; Shevade, Abhijit; Kisor, Adam; Homer, Margie; Jewell, April; Manatt, Kenneth; Torres, Julia; Soler, Jessica; Taylor, Charles

    2009-01-01

    Palladium chloride films have been found to be useful as alternatives to the gold films heretofore used to detect airborne elemental mercury at concentrations of the order of parts per billion (ppb). Somewhat more specifically, when suitably prepared palladium chloride films are exposed to parts-per-billion or larger concentrations of airborne mercury, their electrical resistances change by amounts large enough to be easily measurable. Because airborne mercury adversely affects health, it is desirable to be able to detect it with high sensitivity, especially in enclosed environments in which there is a risk of leakage of mercury from lamps or other equipment. The detection of mercury by use of gold films involves the formation of gold/mercury amalgam. Gold films offer adequate sensitivity for detection of airborne mercury and could easily be integrated into an electronic-nose system designed to operate in the temperature range of 23 to 28 C. Unfortunately, in order to regenerate a gold-film mercury sensor, one must heat it to a temperature of 200 C for several minutes in clean flowing air. In preparation for an experiment to demonstrate the present sensor concept, palladium chloride was deposited from an aqueous solution onto sets of gold electrodes and sintered in air to form a film. Then while using the gold electrodes to measure the electrical resistance of the films, the films were exposed, at a temperature of 25 C, to humidified air containing mercury at various concentrations from 0 to 35 ppb (see figure). The results of this and other experiments have been interpreted as signifying that sensors of this type can detect mercury in room-temperature air at concentrations of at least 2.5 ppb and can readily be regenerated at temperatures <40 C.

  4. [Comparing the activity of multiple sclerosis (MS) at the minute and at 20 minutes of gadolinium application in magnetic resonance imaging (MRI) of the brain?

    PubMed

    Saldívar-Uribe, Christina; de la Portilla-Villanueva, Mario Alberto; Esau-Mendoza-García, Alberto

    2017-01-01

    The aim was to compare active disease in patients diagnosed with multiple sclerosis, brain by MRI after gadolinium application at one minute and 20 minutes. A longitudinal, prospective, observational, analytical and comparative study was conducted in 18 patients over 18 years of age diagnosed with multiple sclerosis (MS). An analysis was made for each patient, watching for inflammatory activity in MS lesions, comparing the results to one minute and 20 minutes after the application of gadolinium. For the descriptive analysis, absolute frequencies and percentages were used, as well as means and standard deviations or medians with ranges for the inferential analysis comparing the presence or absence of enhancement in lesions at one minute and 20 minutes; the exact probability test used was Fisher. Finally, the results were analyzed, looking at the gender distribution: 14 (77.8%) were female. The average age was 36.2 ± 9.5 years, with a minimum age of 18 years and a maximum of 55 years; four patients (22.2%) presented further highlight active lesions at 20 minutes, and two patients (11.1%) presented enhancement at one minute. Concluding that MRI in the diagnosis of MS is very important for the detection of activity in lesions caused by the disease, it is evident that the optimum time for evaluation of postcontrast sequences is 20 minutes.

  5. Sleep Patterns in Chinese Preschool Children: A Population-Based Study.

    PubMed

    Wu, Ran; Wang, Guang-Hai; Zhu, Hong; Jiang, Fan; Jiang, Chun-Lei

    2018-04-15

    This study aimed to (1) provide data on normal sleep patterns in Chinese preschool children, (2) identify cross-cultural differences of sleep patterns among children from China and other countries, (3) estimate the prevalence of sleep duration not meeting the optimal amount, and (4) characterize delayed weekend sleep pattern. A population-based sample of 1,610 children aged 3-6 years was recruited from 10 cities across China. Parents completed questions about their child's sleep patterns adapted from the Children's Sleep Habits Questionnaire (CSHQ). The mean bedtime was 9:31 PM, wake time was 7:27 AM, nighttime sleep duration was 9 hours 30 minutes, daytime sleep duration was 1 hour 31 minutes, and total sleep duration was 11 hours 2 minutes. The children had a shorter nighttime sleep duration but longer daytime naps, resulting in no differences in total sleep duration compared with counterparts predominantly in the west. Of the children, 85.3% met the recommended amount of sleep of 10 to 13 hours, and 10.8% slept fewer than 10 hours. The prevalence of sleep less than 10 hours was higher in older children and children from eastern China. Children went to bed and woke up more than 30 minutes later on weekends than weekdays, accounting for 40.1% and 50%, respectively. Children in western China showed longer delay than children in eastern China ( P < .05). Age- and region-specific variability of sleep patterns are reported as well as insufficient sleep and delayed weekend sleep pattern in Chinese preschool children. The cross-cultural difference of sleep patterns was in temporal placement rather than sleep duration. © 2018 American Academy of Sleep Medicine.

  6. Feedback from physical activity monitors is not compatible with current recommendations: A recalibration study.

    PubMed

    Thompson, Dylan; Batterham, Alan M; Peacock, Oliver J; Western, Max J; Booso, Rahuman

    2016-10-01

    Wearable devices to self-monitor physical activity have become popular with individuals and healthcare practitioners as a route to the prevention of chronic disease. It is not currently possible to reconcile feedback from these devices with activity recommendations because the guidelines refer to the amount of activity required on top of normal lifestyle activities (e.g., 150 minutes of moderate-to-vigorous intensity activity per week over-and-above normal moderate-to-vigorous lifestyle activities). The aim of this study was to recalibrate the feedback from self-monitoring. We pooled data from four studies conducted between 2006 and 2014 in patients and volunteers from the community that included both sophisticated measures of physical activity and 10-year risk for cardiovascular disease and type 2 diabetes (n=305). We determined the amount of moderate-to-vigorous intensity activity that corresponded to FAO/WHO/UNU guidance for a required PAL of 1.75 (Total Energy Expenditure/Basal Metabolic Rate). Our results show that, at the UK median PAL, total moderate-to-vigorous intensity physical activity will be around 735 minutes per week (~11% of waking time). We estimate that a 4% increase in moderate-to-vigorous intensity activity will achieve standardised guidance from FAO/WHO/UNU and will require ~1000 minutes of moderate-to-vigorous intensity activity per week. This study demonstrates that feedback from sophisticated wearable devices is incompatible with current physical activity recommendations. Without adjustment, people will erroneously form the view that they are exceeding recommendations by several fold. A more appropriate target from self-monitoring that accounts for normal moderate-to-vigorous lifestyle activities is ~1000 minutes per week, which represents ~15% of waking time. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Sleep, activity and fatigue reported by postgraduate year 1 residents: a prospective cohort study comparing the effects of night-float versus traditional overnight on-call.

    PubMed

    Low, Jia Ming; Tan, Mae Yue; See, Kay Choong; Aw, Marion M

    2018-03-19

    As traditional overnight on-call was shown to contribute to fatigue, Singapore moved to implement a shift system in 2014. We aimed to compare activity levels, sleep (using a wrist actigraph), fatigue and professional quality-of-life between residents working on night-float and those working on traditional overnight on-call. All postgraduate year 1 (PGY1) residents at our institution were invited to participate. Participants were required to wear a wrist actigraph for four months, and complete two validated surveys (Epworth Sleepiness Scale [ESS] and Professional Quality of Life Scale [ProQOL]) once each at the start and at the end of study. 49 residents were recruited. Residents on night-float and on-call showed comparable median (range) number of steps (10,061 [1,195-15,923] vs. 10,649 [308-21,910]; p = 0.429), amount of sleep logged (361 [149-630] minutes vs. 380 [175-484] minutes; p = 0.369) and time taken to fall asleep (6 [0-14] minutes vs. 6 [range 0-45] minutes; p = 0.726) respectively. Residents on night-float had less efficient sleep, with 90.5% participants having over 85% sleep efficiency compared to 100% of residents on on-call (p = 0.127). More residents on night-float reported ESS > 10 (73.8% vs. 38.5%) and higher burnout scores on ProQOL (41.4% vs. 21.4%) at the start of the study. However, this was similar to the end of the study and was not statistically significant. The physical activity and amount of sleep of residents on night-float and on-call rota were not significantly different. Residents on night-float reported comparatively higher fatigue and burnout.

  8. 78 FR 54729 - Reports, Forms, and Record Keeping Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-05

    ... information: Title--NHTSA Distracted Driving Survey Project. Type of Request--Revision of previously approved... region, age, and gender. The National Survey on Distracted Driving Attitudes and Behaviors (NSDDAB) will... driving behaviors. The estimated average amount of time to complete the survey is 20 minutes. This...

  9. Bacitracin zinc overdose

    MedlinePlus

    ... amount of the product. This can be by accident or on purpose. This article is for information ... water for at least 15 minutes. If the chemical was swallowed, immediately give the person water or ... A.D.A.M.'s editorial policy , editorial process and privacy policy . A.D.A.M. is ...

  10. Bacitracin overdose

    MedlinePlus

    ... amount of the product. This can be by accident or on purpose. This article is for information ... water for at least 15 minutes. If the chemical was swallowed, give the person water or milk right ... A.D.A.M.'s editorial policy , editorial process and privacy policy . A.D.A.M. is ...

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Xing; Xu, Yanli; Meng, Qian

    Colorectal cancer (CRC) is one of the most common types of malignant tumor worldwide. Currently, although many researchers have been devoting themselves in CRC studies, the process of locating biomarkers for CRC early diagnosis and prognostic is still very slow. Using a centrifugal proteomic reactor-based proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling, 2620 protein groups were quantified between cancer mucosa and adjacent normal colorectal mucosa. Of which, 403 protein groups were differentially expressed with statistic significance between cancer and normal tissues, including 195 up-regulated and 208 down-regulated proteins in cancer tissues. Three proteins (SOD3, PRELP andmore » NGAL) were selected for further Western blot validation. And the resulting Western blot experimental results were consistent with the quantitative proteomic data. SOD3 and PRELP are down-regulated in CRC mucosa comparing to adjacent normal tissue, while NGAL is up-regulated in CRC mucosa. In conclusion, the centrifugal proteomic reactor-based label-free quantitative proteomic approach provides a highly sensitive and powerful tool for analyzing minute protein sample from tiny colorectal biopsies, which may facilitate CRC biomarkers discovery for diagnoses and prognoses. -- Highlights: •Minute amount of colonic biopsies by endoscopy is suitable for proteomic analysis. •Centrifugal proteomic reactor can be used for processing tiny clinic biopsy sample. •SOD3 and PRELP are down-regulated in CRC, while NGAL is up-regulated in CRC.« less

  12. The effects of two torque values on the screw preload of implant-supported prostheses with passive fit or misfit.

    PubMed

    Al-Otaibi, Hanan Nejer; Akeel, Riyadh Fadul

    2014-01-01

    To determine the effect of increased torque of the abutment screw and retorquing after 10 minutes on implant-supported fixed prostheses. Two strain gauges (SGs) were attached to four implants stabilized on an acrylic resin mandible. Four implant-supported frameworks were constructed to represent passive fit (PF) and different amounts of misfit (MF1, MF2, and MF3). Vertical misfit was measured using a traveling microscope. Each framework was torqued to 35 Ncm (the manufacturer's recommendation) and 40 Ncm, and the preload was recorded immediately and again after retorquing 10 minutes later (torque stage). The smallest gap was observed under the PF framework. Three-way analysis of variance revealed significant effects of the framework, torque value, and torque stage on preload. The PF showed the highest mean preload under both torque values. An independent-sample t test between the torque values revealed a statistically significant difference only for MF1 and MF2. A dependent-sample t test of the torque stage revealed a statistically significant difference at a torque value of 35 Ncm under the PF and MF3 frameworks. Increasing the torque value beyond the manufacturer's recommended amount and retorquing of the screws at 10 minutes after the initial torque did not necessarily lead to a significant increase in preload in full-arch implant-supported fixed prostheses, particularly under non-passively fitting frameworks.

  13. LOSS OF BLOOD AT OPERATION—A Method for Continuous Measurement

    PubMed Central

    Borden, Fred W.

    1957-01-01

    A method for continuous measurement of surgical blood loss has been devised and has been used clinically in some 400 cases. The method combines volumetric measure of the suction loss and gravimetric measure of the sponge loss. The volumetric device automatically deducts the volume of rinse water used and thus measures the amount of blood collected in a metering cylinder. The suction loss scale shows continuously the amount of blood in the metering cylinder. The gravimetric device requires counting sponges into the weighing pan, and turning a dial scale to deduct the initial weight of the sponges. The volume of blood in the sponges is then read directly on the dial scale. Use of the instrument, which is under the supervision of the anesthesiologist, adds about two minutes per hour to the time normally required for counting the sponges; and about three minutes per hour is required for tending the volumetric instrument. In clinical use, knowing constantly the amount of blood loss permits the starting of transfusion before serious deficit develops, and then maintaining the patient's blood volume at a predetermined optimum level. In some 400 cases the continuous measurement of the blood loss served as a reliable guide for carrying out the loss-replacement plan within close limits of accuracy. ImagesFigure 2.p97-a PMID:13446754

  14. The Misgav Ladach method for cesarean section compared to the Pfannenstiel method.

    PubMed

    Darj, E; Nordström, M L

    1999-01-01

    The aim of the study was to evaluate the outcome of two different methods of cesarean section (CS). The study was designed as a prospective, randomized, controlled trial. All CS were performed at the University Hospital in Uppsala, Sweden. Fifty women admitted to hospital for a first elective CS were consecutively included in the study. They were randomly allocated to two groups. One group was operated on by the Misgav Ladach method for CS and the other group by the Pfannenstiel method. All operations were performed by the same surgeon. Duration of operation, amount of bleeding, analgesics required, scar appearance and length of hospitalization. Operating time was significantly different between the two methods, with an average of 12.5 minutes with the Misgav Ladach method and 26 minutes with the Pfannenstiel method (p<0.001). The amount of blood loss differed significantly, with 448 ml and 608 ml respectively (p=0.017). Significantly less analgesic injections and tablets (p=0.004) were needed after the Misgav Ladach method. The Misgav Ladach method of CS has advantages over the Pfannenstiel method by being significantly quicker to perform, with a reduced amount of bleeding and diminished postoperative pain. The women were satisfied with the appearance of their scars. In this study no negative effects of the new operation technique were discovered.

  15. An Event-Based Verification Scheme for the Real-Time Flare Detection System at Kanzelhöhe Observatory

    NASA Astrophysics Data System (ADS)

    Pötzi, W.; Veronig, A. M.; Temmer, M.

    2018-06-01

    In the framework of the Space Situational Awareness program of the European Space Agency (ESA/SSA), an automatic flare detection system was developed at Kanzelhöhe Observatory (KSO). The system has been in operation since mid-2013. The event detection algorithm was upgraded in September 2017. All data back to 2014 was reprocessed using the new algorithm. In order to evaluate both algorithms, we apply verification measures that are commonly used for forecast validation. In order to overcome the problem of rare events, which biases the verification measures, we introduce a new event-based method. We divide the timeline of the Hα observations into positive events (flaring period) and negative events (quiet period), independent of the length of each event. In total, 329 positive and negative events were detected between 2014 and 2016. The hit rate for the new algorithm reached 96% (just five events were missed) and a false-alarm ratio of 17%. This is a significant improvement of the algorithm, as the original system had a hit rate of 85% and a false-alarm ratio of 33%. The true skill score and the Heidke skill score both reach values of 0.8 for the new algorithm; originally, they were at 0.5. The mean flare positions are accurate within {±} 1 heliographic degree for both algorithms, and the peak times improve from a mean difference of 1.7± 2.9 minutes to 1.3± 2.3 minutes. The flare start times that had been systematically late by about 3 minutes as determined by the original algorithm, now match the visual inspection within -0.47± 4.10 minutes.

  16. Fluoride bioavailability in saliva and plaque

    PubMed Central

    2012-01-01

    Background Different fluoride formulations may have different effects on caries prevention. It was the aim of this clinical study to assess the fluoride content, provided by NaF compared to amine fluoride, in saliva and plaque. Methods Eight trained volunteers brushed their teeth in the morning for 3 minutes with either NaF or amine fluoride, and saliva and 3-day-plaque-regrowth was collected at 5 time intervals during 6 hours after tooth brushing. The amount of collected saliva and plaque was measured, and the fluoride content was analysed using a fluoride sensitive electrode. All subjects repeated all study cycles 5 times, and 3 cycles per subject underwent statistical analysis using the Wilcoxon-Mann-Whitney test. Results Immediately after brushing the fluoride concentration in saliva increased rapidly and dropped to the baseline level after 360 minutes. No difference was found between NaF and amine fluoride. All plaque fluoride levels were elevated after 30 minutes until 120 minutes after tooth brushing, and decreasing after 360 minutes to baseline. According to the highly individual profile of fluoride in saliva and plaque, both levels of bioavailability correlated for the first 30 minutes, and the fluoride content of saliva and plaque was back to baseline after 6 hours. Conclusions Fluoride levels in saliva and plaque are interindividually highly variable. However, no significant difference in bioavailability between NaF and amine fluoride, in saliva, or in plaque was found. PMID:22230722

  17. Brief ultrasonication improves detection of biofilm-formative bacteria around a metal implant.

    PubMed

    Kobayashi, Naomi; Bauer, Thomas W; Tuohy, Marion J; Fujishiro, Takaaki; Procop, Gary W

    2007-04-01

    Biofilms are complex microenvironments produced by microorganisms on surfaces. Ultrasonication disrupts biofilms and may make the microorganism or its DNA available for detection. We determined whether ultrasonication could affect our ability to detect bacteria adherent to a metal substrate. A biofilm-formative Staphylococcus aureus strain was used for an in vitro implant infection model (biofilm-formative condition). We used quantitative culture and real time-polymerase chain reaction to determine the influence of different durations of ultrasound on bacterial adherence and viability. Sonication for 1 minute increased the yield of bacteria. Sonication longer than 5 minutes led to fewer bacterial colonies by conventional culture but not by polymerase chain reaction. This suggests short periods of sonication help release bacteria from the metal substrate by disrupting the biofilm, but longer periods of sonication lyse bacteria prohibiting their detection in microbiologic cultures. A relatively short duration of sonication may be desirable for maximizing detection of biofilm-formative bacteria around implants by culture or polymerase chain reaction.

  18. Reproducibility and responsiveness of quality of life assessment and six minute walk test in elderly heart failure patients.

    PubMed

    O'Keeffe, S T; Lye, M; Donnellan, C; Carmichael, D N

    1998-10-01

    To examine the reproducibility and responsiveness to change of a six minute walk test and a quality of life measure in elderly patients with heart failure. Longitudinal within patient study. 60 patients with heart failure (mean age 82 years) attending a geriatric outpatient clinic, 45 of whom underwent a repeat assessment three to eight weeks later. Subjects underwent a standardised six minute walk test and completed the chronic heart failure questionnaire (CHQ), a heart failure specific quality of life questionnaire. Intraclass correlation coefficients (ICC) were calculated using a random effects one way analysis of variance as a measure of reproducibility. Guyatt's responsiveness coefficient and effect sizes were calculated as measures of responsiveness to change. 24 patients reported no major change in cardiac status, while seven had deteriorated and 14 had improved between the two clinic visits. Reproducibility was satisfactory (ICC > 0.75) for the six minute walk test, for the total CHQ score, and for the dyspnoea, fatigue, and emotion domains of the CHQ. Effect sizes for all measures were large (> 0.8), and responsiveness coefficients were very satisfactory (> 0.7). Effect sizes for detecting deterioration were greater than those for detecting improvement. Quality of life assessment and a six minute walk test are reproducible and responsive measures of cardiac status in frail, very elderly patients with heart failure.

  19. Bronchoscopic assessment of airway retention time of aerosolized xylitol

    PubMed Central

    Durairaj, Lakshmi; Neelakantan, Srividya; Launspach, Janice; Watt, Janet L; Allaman, Margaret M; Kearney, William R; Veng-Pedersen, Peter; Zabner, Joseph

    2006-01-01

    Background Human airway surface liquid (ASL) has abundant antimicrobial peptides whose potency increases as the salt concentration decreases. Xylitol is a 5-carbon sugar that has the ability to lower ASL salt concentration, potentially enhancing innate immunity. Xylitol was detected for 8 hours in the ASL after application in airway epithelium in vitro. We tested the airway retention time of aerosolized iso-osmotic xylitol in healthy volunteers. Methods After a screening spirometry, volunteers received 10 ml of nebulized 5% xylitol. Bronchoscopy was done at 20 minutes (n = 6), 90 minutes (n = 6), and 3 hours (n = 5) after nebulization and ASL was collected using microsampling probes, followed by bronchoalveolar lavage (BAL). Xylitol concentration was measured by nuclear magnetic resonance spectroscopy and corrected for dilution using urea concentration. Results All subjects tolerated nebulization and bronchoscopy well. Mean ASL volume recovered from the probes was 49 ± 23 μl. The mean ASL xylitol concentration at 20, 90, and 180 minutes was 1.6 ± 1.9 μg/μl, 0.6 ± 0.6 μg/μl, and 0.1 ± 0.1 μg/μl, respectively. Corresponding BAL concentration corrected for dilution was consistently lower at all time points. The terminal half-life of aerosolized xylitol obtained by the probes was 45 minutes with a mean residence time of 65 minutes in ASL. Corresponding BAL values were 36 and 50 minutes, respectively. Conclusion After a single dose nebulization, xylitol was detected in ASL for 3 hours, which was shorter than our in vitro measurement. The microsampling probe performed superior to BAL when sampling bronchial ASL. PMID:16483382

  20. Detection and clearance of prostate cells subsequent to ultrasound-guided needle biopsy as determined by multiplex nested reverse transcription polymerase chain reaction assay.

    PubMed

    Price, D K; Clontz, D R; Woodard, W L; Kaufman, J S; Daniels, J M; Stolzenberg, S J; Teigland, C M

    1998-08-01

    To determine if circulating prostate cells are detectable subsequent to transrectal ultrasound (TRUS)-guided biopsy, and if so, whether cells remain in circulation for up to 4 weeks. Blood samples were drawn from 90 patients with elevated serum prostate-specific antigen (PSA) levels and/or abnormal digital rectal examination. Two samples were drawn from all patients immediately prior to TRUS and 30 minutes postbiopsy. Blood samples were also obtained 1 week postbiopsy from 83 patients, and 1 month postbiopsy from 61 patients. Multiplex nested reverse transcription polymerase chain reaction assay (RT-PCR) for PSA and prostate-specific membrane antigen (PSM) was performed on total ribonucleic acid (RNA) from each sample. Results were reported as positive if at least one of the targets was detected. Of 45 patients with biopsy-proven adenocarcinoma, 22 were RT-PCR positive prebiopsy and all remained positive 30 minutes postbiopsy. Of 23 patients with adenocarcinoma who were RT-PCR negative prebiopsy, 5 (22%) converted to positive 30 minutes postbiopsy (P < 0.001). Four of these 5 patients returned to negative after 1 week or 1 month. Of 45 patients without cancer at biopsy, 32 were RT-PCR negative prebiopsy and 6 (19%) converted to positive 30 minutes postbiopsy (P < 0.001). Although four of six available samples were still positive at 1 week, all four samples available 1 month postbiopsy were negative. Detection of circulating prostate cells subsequent to biopsy occurred in 11 of 55 (20%) previously RT-PCR negative patients, a proportion twice that reported in the literature. We attribute this higher proportion to the simultaneous detection of PSA and PSM mRNA in our multiplex assay. Conversion rates were similar in patients regardless of biopsy result. Testing of serial postbiopsy blood demonstrates clearing of these cells by 4 weeks in most patients.

  1. An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.

    PubMed

    Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa

    2016-04-01

    To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS(®) assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1%) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. An Abbreviated Protocol for High-Risk Screening Breast MRI Saves Time and Resources.

    PubMed

    Harvey, Susan C; Di Carlo, Phillip A; Lee, Bonmyong; Obadina, Eniola; Sippo, Dorothy; Mullen, Lisa

    2016-11-01

    To review the ability of an abbreviated, high-risk, screening, breast MRI protocol to detect cancer and save resources. High-risk screening breast MR images were reviewed, from both an abbreviated protocol and a full diagnostic protocol. Differences in cancer detection, scanner utilization, interpretation times, and need for additional imaging were recorded in an integrated data form, and reviewed and compared. A total of 568 MRI cases were reviewed, with the abbreviated and full protocols. No difference was found in the number of cancers detected. Scan times were decreased by 18.8 minutes per case, for a total of 10,678 minutes (178 hours). Interpretation time, on average, was 1.55 minutes for the abbreviated protocol, compared with 6.43 minutes for the full protocol. Review of the full protocol led to a significant change in the final BI-RADS ® assessment in 12 of 568 (2.1%) cases. Abbreviated MRI is as effective as full-protocol MRI for demonstration of cancers in the high-risk screening setting, with only 12 (2.1 %) cases recommended for additional MRI evaluation. The efficiency and resource savings of an abbreviated protocol would be significant, and would allow for opportunities to provide MRI for additional patients, as well as improved radiologist time management and workflow, with the potential to add real-time MRI interpretation or double reading. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Morphological Changes Along a Dike Landside Slope Sampled by 4d High Resolution Terrestrial Laser Scanning

    NASA Astrophysics Data System (ADS)

    Herrero-Huertaa, Mónica; Lindenbergh, Roderik; Ponsioen, Luc; van Damme, Myron

    2016-06-01

    Emergence of light detection and ranging (LiDAR) technology provides new tools for geomorphologic studies improving spatial and temporal resolution of data sampling hydrogeological instability phenomena. Specifically, terrestrial laser scanning (TLS) collects high resolution 3D point clouds allowing more accurate monitoring of erosion rates and processes, and thus, quantify the geomorphologic change on vertical landforms like dike landside slopes. Even so, TLS captures observations rapidly and automatically but unselectively. In this research, we demonstrate the potential of TLS for morphological change detection, profile creation and time series analysis in an emergency simulation for characterizing and monitoring slope movements in a dike. The experiment was performed near Schellebelle (Belgium) in November 2015, using a Leica Scan Station C10. Wave overtopping and overflow over a dike were simulated whereby the loading conditions were incrementally increased and 14 successful scans were performed. The aim of the present study is to analyse short-term morphological dynamic processes and the spatial distribution of erosion and deposition areas along a dike landside slope. As a result, we are able to quantify the eroded material coming from the impact on the terrain induced by wave overtopping which caused the dike failure in a few minutes in normal storm scenarios (Q = 25 l/s/m) as 1.24 m3. As this shows that the amount of erosion is measurable using close range techniques; the amount and rate of erosion could be monitored to predict dike collapse in emergency situation. The results confirm the feasibility of the proposed methodology, providing scalability to a comprehensive analysis over a large extension of a dike (tens of meters).

  4. Comparison of Point Count Sampling Regimes for Monitoring Forest Birds

    Treesearch

    William H. Buskirk; Jennifer L. McDonald

    1995-01-01

    A set of 255 counts was compiled for 13 points using 10-minute periods subtallied at 3 and 6 minutes. The data from each point were subsampled using combinations of count periods, numbers, and schedules to compare the effectiveness of these different regimes at per point coverage. Interspecifically, detection frequencies differed in level and pattern as a function of...

  5. Emission of Volatile Sulfur Compounds from Spruce Trees 1

    PubMed Central

    Rennenberg, Heinz; Huber, Beate; Schröder, Peter; Stahl, Klaus; Haunold, Werner; Georgii, Hans-Walter; Slovik, Stefan; Pfanz, Hardy

    1990-01-01

    Spruce (Picea Abies L.) trees from the same clone were supplied with different, but low, amounts of plant available sulfate in the soil (9.7-18.1 milligrams per 100 grams of soil). Branches attached to the trees were enclosed in a dynamic gas exchange cuvette and analyzed for the emission of volatile sulfur compounds. Independent of the sulfate supply in the soil, H2S was the predominant reduced sulfur compound continuously emitted from the branches with high rates during the day and low rates in the night. In the light, as well as in the dark, the rates of H2S emission increased exponentially with increasing water vapor flux from the needles. Approximately 1 nanomole of H2S was found to be emitted per mole of water. When stomata were closed completely, only minute emission of H2S was observed. Apparently, H2S emission from the needles is highly dependent on stromatal aperture, and permeation through the cuticle is negligible. In several experiments, small amounts of dimethylsulfide and carbonylsulfide were also detected in a portion of the samples. However, SO2 was the only sulfur compound consistently emitted from branches of spruce trees in addition to H2S. Emission of SO2 mainly proceeded via an outburst starting before the beginning of the light period. The total amount of SO2 emitted from the needles during this outburst was correlated with the plant available sulfate in the soil. The diurnal changes in sulfur metabolism that may result in an outburst of SO2 are discussed. PMID:16667315

  6. 78 FR 57926 - Agency Information Collection (Application for Accrued Amounts Due a Deceased Beneficiary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-20

    ... Control No. 2900- 0216'' in any correspondence. FOR FURTHER INFORMATION CONTACT: Crystal Rennie... 20420, (202) 632-7492 or email crystal[email protected] . Please refer to ``OMB Control No. 2900-0216... Average Burden per Respondent: 30 minutes. Frequency of Response: One time. Estimated Number of...

  7. A Neutron Based Interrogation System For SNM In Cargo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kane, Steven Z.; Koltick, David S.

    A complete system has been simulated using experimentally obtained input parameters for the detection of special nuclear materials (SNM). A variation of the associated particle imaging (API) technique, referred to as reverse associated particle imaging detection (RAPID), has been developed in the context of detecting 5-kg spherical samples of U-235 in cargo. The RAPID technique allows for the interrogation of containers at neutron production rates between {approx}1x10{sup 8} neutrons/s and {approx}3x10{sup 8} neutrons/s. The merit of performance for the system is the time to detect the threat material with 95% probability of detection and 10{sup -4} false positive rate permore » interrogated voxel of cargo. Detection times of 5 minutes were found for a maximally loaded cargo container uniformly filled with iron and as low as 1 second in containers loaded to 1/4 of full capacity with either iron or wood. The worse case system performance, 30 minutes interrogation time, occurs for a maximally loaded container containing wood at 0.4 g/cm{sup 3}.« less

  8. Disk-based k-mer counting on a PC

    PubMed Central

    2013-01-01

    Background The k-mer counting problem, which is to build the histogram of occurrences of every k-symbol long substring in a given text, is important for many bioinformatics applications. They include developing de Bruijn graph genome assemblers, fast multiple sequence alignment and repeat detection. Results We propose a simple, yet efficient, parallel disk-based algorithm for counting k-mers. Experiments show that it usually offers the fastest solution to the considered problem, while demanding a relatively small amount of memory. In particular, it is capable of counting the statistics for short-read human genome data, in input gzipped FASTQ file, in less than 40 minutes on a PC with 16 GB of RAM and 6 CPU cores, and for long-read human genome data in less than 70 minutes. On a more powerful machine, using 32 GB of RAM and 32 CPU cores, the tasks are accomplished in less than half the time. No other algorithm for most tested settings of this problem and mammalian-size data can accomplish this task in comparable time. Our solution also belongs to memory-frugal ones; most competitive algorithms cannot efficiently work on a PC with 16 GB of memory for such massive data. Conclusions By making use of cheap disk space and exploiting CPU and I/O parallelism we propose a very competitive k-mer counting procedure, called KMC. Our results suggest that judicious resource management may allow to solve at least some bioinformatics problems with massive data on a commodity personal computer. PMID:23679007

  9. [Practice value of whole genome amplification technology to be used in forensic science and analysis of its result].

    PubMed

    Deng, Jian-qiang; Hou, Yi-ping

    2005-08-01

    Genetic analysis from forensic microsamples is a urgent, difficult task in forensic science, because it is frequently limited by the amount of specimen available in forensic practice, much effort has been carried out to resolve this difficulty. Whole genome amplification (WGA) technology, which was developing quickly in these years, has been thought to be a powerful, reliable and efficient strategy in analysis of minute amount DNA on many fields. In this review, we discuss its application in forensic science.

  10. High spatial and temporal resolution cell manipulation techniques in microchannels.

    PubMed

    Novo, Pedro; Dell'Aica, Margherita; Janasek, Dirk; Zahedi, René P

    2016-03-21

    The advent of microfluidics has enabled thorough control of cell manipulation experiments in so called lab on chips. Lab on chips foster the integration of actuation and detection systems, and require minute sample and reagent amounts. Typically employed microfluidic structures have similar dimensions as cells, enabling precise spatial and temporal control of individual cells and their local environments. Several strategies for high spatio-temporal control of cells in microfluidics have been reported in recent years, namely methods relying on careful design of the microfluidic structures (e.g. pinched flow), by integration of actuators (e.g. electrodes or magnets for dielectro-, acousto- and magneto-phoresis), or integrations thereof. This review presents the recent developments of cell experiments in microfluidics divided into two parts: an introduction to spatial control of cells in microchannels followed by special emphasis in the high temporal control of cell-stimulus reaction and quenching. In the end, the present state of the art is discussed in line with future perspectives and challenges for translating these devices into routine applications.

  11. Quantification of Endogenous Cholesterol in Human Serum on Paper Using Direct Analysis in Real Time Mass Spectrometry.

    PubMed

    Hsieh, Hua-Yi; Li, Li-Hua; Hsu, Ren-Yu; Kao, Wei-Fong; Huang, Ying-Chen; Hsu, Cheng-Chih

    2017-06-06

    Blood testing for endogenous small metabolites to determine physiological and biochemical states is routine for laboratory analysis. Here we demonstrate that by combining the commercial direct analysis in real time (DART) ion source with an ion trap mass spectrometer, native cholesterol in its free alcohol form is readily detected from a few hundred nanoliters of human serum loaded onto chromatography paper. Deuterium-labeled cholesterol was used as the internal standard to obtain the absolute quantity of the endogenous cholesterol. The amount of the cholesterol measured by this paper-loaded DART mass spectrometry (pDART-MS) is statistically comparable with that obtained by using commercially available fluorometric-enzymatic assay and liquid chromatography/mass spectrometry. Furthermore, sera from 21 participants at three different time points in an ultramarathon were collected to obtain their cholesterol levels. The test requires only very minimal sample preparation, and the concentrations of cholesterol in each sample were acquired within a minute.

  12. Pluto and Charon in Color: Pluto-Centric View Animation

    NASA Image and Video Library

    2015-06-11

    The first color movies from NASA's New Horizons mission show Pluto and its largest moon, Charon, and the complex orbital dance of the two bodies, known as a double planet. A near-true color movie were assembled from images made in three colors -- blue, red and near-infrared -- by the Multispectral Visible Imaging Camera on the instrument known as Ralph. The images were taken on nine different occasions from May 29-June 3, 2015. The movie is "Pluto-centric," meaning that Charon is shown as it moves in relation to Pluto, which is digitally centered in the movie. (The North Pole of Pluto is at the top.) Pluto makes one turn around its axis every 6 days, 9 hours and 17.6 minutes-the same amount of time that Charon rotates in its orbit. Looking closely at the images in this movie, one can detect a regular shift in Pluto's brightness-due to the brighter and darker terrains on its differing faces. http://photojournal.jpl.nasa.gov/catalog/PIA19689

  13. X-ray fluorescence surface contaminant analyzer: A feasibility study

    NASA Technical Reports Server (NTRS)

    Eldridge, Hudson B.

    1988-01-01

    The bonding of liner material to the inner metal surfaces of solid rocket booster cases is adversely affected by minute amounts of impurities on the metal surface. Suitable non-destructive methods currently used for detecting these surface contaminants do not provide the means of identifying their elemental composition. The feasibility of using isotopic source excited energy dispersive X-ray fluorescence as a possible technique for elemental analysis of such contaminants is investigated. A survey is made of the elemental compositions of both D-6ac steel, a common construction material for the booster cases, and Conoco HD-2 grease, a common surface contamination. Source and detector choices that maximize signal to noise ratio in a Recessed Source Geometry are made. A Monte Carlo simulation is then made of the optimized device incorporating the latest available X-ray constants at the energy of the chosen source to determine the device's response to a D-6ac steel surface contained with Conoco HD-2 grease.

  14. Photothermal method of determining calorific properties of coal

    DOEpatents

    Amer, Nabil M.

    1985-01-01

    Predetermined amounts of heat are generated within a coal sample (11) by directing pump light pulses (14) of predetermined energy content into a small surface region (16) of the sample (11). A beam (18) of probe light is directed along the sample surface (19) and deflection of the probe beam (18) from thermally induced changes of index of refraction in the fluid medium adjacent the heated region (16) are detected. Deflection amplitude and the phase lag of the deflection, relative to the initiating pump light pulse (14), are indicative of the calorific value and the porosity of the sample (11). The method provides rapid, accurate and non-destructive analysis of the heat producing capabilities of coal samples (11). In the preferred form, sequences of pump light pulses (14) of increasing durations are directed into the sample (11) at each of a series of minute regions (16) situated along a raster scan path (21) enabling detailed analysis of variations of thermal properties at different areas of the sample (11) and at different depths.

  15. Ultrasensitive Direct Quantification of Nucleobase Modifications in DNA by Surface-Enhanced Raman Scattering: The Case of Cytosine.

    PubMed

    Morla-Folch, Judit; Xie, Hai-nan; Gisbert-Quilis, Patricia; Gómez-de Pedro, Sara; Pazos-Perez, Nicolas; Alvarez-Puebla, Ramon A; Guerrini, Luca

    2015-11-09

    Recognition of chemical modifications in canonical nucleobases of nucleic acids is of key importance since such modified variants act as different genetic encoders, introducing variability in the biological information contained in DNA. Herein, we demonstrate the feasibility of direct SERS in combination with chemometrics and microfluidics for the identification and relative quantification of 4 different cytosine modifications in both single- and double-stranded DNA. The minute amount of DNA required per measurement, in the sub-nanogram regime, removes the necessity of pre-amplification or enrichment steps (which are also potential sources of artificial DNA damages). These findings show great potentials for the development of fast, low-cost and high-throughput screening analytical devices capable of detecting known and unknown modifications in nucleic acids (DNA and RNA) opening new windows of activity in several fields such as biology, medicine and forensic sciences. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Autonomous acoustic recorders reveal complex patterns in avian detection probability

    USGS Publications Warehouse

    Thompson, Sarah J.; Handel, Colleen M.; McNew, Lance B.

    2017-01-01

    Avian point‐count surveys are typically designed to occur during periods when birds are consistently active and singing, but seasonal and diurnal patterns of detection probability are often not well understood and may vary regionally or between years. We deployed autonomous acoustic recorders to assess how avian availability for detection (i.e., the probability that a bird signals its presence during a recording) varied during the breeding season with time of day, date, and weather‐related variables at multiple subarctic tundra sites in Alaska, USA, 2013–2014. A single observer processed 2,692 10‐minute recordings across 11 site‐years. We used time‐removal methods to assess availability and used generalized additive models to examine patterns of detectability (joint probability of presence, availability, and detection) for 16 common species. Despite lack of distinct dawn or dusk, most species displayed circadian vocalization patterns, with detection rates generally peaking between 0800 hours and 1200 hours but remaining high as late as 2000 hours for some species. Between 2200 hours and 0500 hours, most species’ detection rates dropped to near 0, signaling a distinctive rest period. Detectability dropped sharply for most species in early July. For all species considered, time‐removal analysis indicated nearly 100% likelihood of detection during a 10‐minute recording conducted in June, between 0500 hours and 2000 hours. This indicates that non‐detections during appropriate survey times and dates were attributable to the species’ absence or that silent birds were unlikely to initiate singing during a 10‐minute interval, whereas vocally active birds were singing very frequently. Systematic recordings revealed a gradient of species’ presence at each site, from ubiquitous to incidental. Although the total number of species detected at a site ranged from 16 to 27, we detected only 4 to 15 species on ≥5% of the site's recordings. Recordings provided an unusually detailed and consistent dataset that allowed us to identify, among other things, appropriate survey dates and times for species breeding at northern latitudes. Our results also indicated that more recordings of shorter duration (1–4 min) may be most efficient for detecting passerines.

  17. Numerical evaluation of ECT impedance signal due to minute cracks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fukutomi, Hiroyuki; Takagi, Toshiyuki; Tani, Junji

    1997-03-01

    This paper describes an experimental and analytical study on minute crack inspection with Eddy Current Testing (ECT). Measurement and simulation using a 3D FEM program are applied for the evaluation of the detecting signal with a minute crack in a test piece. Parameters such as mesh division, ICCG convergence criteria, etc. are evaluated to achieve high accuracy in numerical calculation. The simulation results agreed with experimental ones. ECT is used for in-service inspection of tubes in steam generators, heat exchangers and condensers in nuclear or conventional power plants as well as in chemical installations.

  18. MASTER OT J072007.30+451611.6: Cataclysmic Variable with an Extreme Hot Spot

    NASA Astrophysics Data System (ADS)

    Denisenko, D.

    2018-05-01

    MASTER team has reported an unusual object MASTER OT J072007.30+451611.6 in ATel #11620 (T. Pogrosheva et al.). The object was observed at 17.0-17.2m during 9 minutes from 22:15:26 to 22:24:30 UT on 2018-04-26, but was below the detection limit (18.8m) 45 minutes before the first positive observation and 43 minutes after the last one. As noted by S. Otero in AAVSO VSX entry, MASTER OT J072007.30+451611.6 has an X-ray counterpart XMMSL2 J072007.4+451615.

  19. Electricity Cogenerator from Hydrogen and Biogas

    NASA Astrophysics Data System (ADS)

    Pinate, W.; Chinnasa, P.; Dangphonthong, D.

    2017-09-01

    This research studied about electricity cogenerator from Hydrogen and Biogas and the factors that cause that effecting Hydrogen from Aluminium which was a cylindrical feature. By using a catalyst was NaOH and CaO, it was reacted in distilled water with percentage of Aluminium: the catalyst (NaOH and CaO) and brought to mix with Biogas afterwards, that have been led to electricity from generator 1 kilowatt. The research outcomes were concentration of solutions that caused amount and percent of maximum Hydrogen was to at 10 % wt and 64.73 % which rate of flowing of constant gas 0.56 litter/minute as temperature 97 degree Celsius. After that led Hydrogen was mixed by Biogas next, conducted to electricity from generator and levelled the voltage of generator at 220 Volt. There after the measure of electricity current and found electricity charge would be constant at 3.1 Ampere. And rate of Biogas flowing and Hydrogen, the result was the generator used Biogas rate of flowing was highest 9 litter/minute and the lowest 7.5 litter/minute, which had rate of flowing around 8.2 litter/minute. Total Biogas was used around 493.2 litter or about 0.493 m3 and Hydrogen had rate of flowing was highest 2.5 litter/minute.

  20. [Psoriasis: the clinical use of "minute therapy" with Cignolin].

    PubMed

    Runne, U; Kunze, J

    1983-02-15

    The so called "minutes" therapy is a fundamental new method of psoriasis treatment with dithranol (anthralin). Dithranol is applied to the lesions for only 10 to 20 minutes and thereafter washed off thoroughly under a shower. We use an ointment of 0.5 to 3% dithranol with 2% salicylic acid in yellow soft paraffin which is applied with a plastic glove to the lesions. This regimen makes it now possible to offer dithranol routinely for home treatment. The patient should be well informed and must consult the dermatologist weekly. The course of treatment usually starts with 1% dithranol for 10 minutes. Depending on the healing effect and the degree of irritation, the concentration and the contact time is increased step by step. Up to now, 200 patients have been treated, 64 of them as in-patients and 136 carrying out the treatment at home. The clearance rate was 77.5% (84% for the in-patients and 74% for the outpatients). The average clearing time for out-patients was 5.5 days longer than for in-patients (31.5 to 26 days). The rate of non-responders in both groups was 10%. The application of corticosteroids or oral retinoids in addition to the "minutes" therapy showed no better therapeutic results. The "minutes" therapy has medical, social and financial advantages. Dithranol is very effective and has no permanent side-effects. Therefore, corticosteroids, retinoids and PUVA can be restricted. Treatment at home enables the patients to enjoy normal family and professional life. Finally, the "minutes" therapy saves large amounts of money in comparison to a hospital stay for several weeks.

  1. Triple dose of gadolinium-DTPA and delayed MRI in patients with benign multiple sclerosis.

    PubMed Central

    Filippi, M; Capra, R; Campi, A; Colombo, B; Prandini, F; Marcianò, N; Gasparotti, R; Comi, G

    1996-01-01

    OBJECTIVES--To evaluate whether a triple dose of gadolinium-DTPA (Gd-DTPA) or delayed MRI increase the number, size, and conspicuousness of enhancing lesions in patients with benign multiple sclerosis. METHODS--T1 weighted brain MRI was carried out on 20 patients with benign multiple sclerosis (expanded disability status scale < 3 with a disease duration > 10 years) in two sessions. In the first session, one scan was obtained before and two scans five to seven minutes and 20-30 minutes after the injection of 0.1 mmol/kg Gd-DTPA (standard dose). In the second session, six to 24 hours later, the same procedure was repeated with 0.3 mmol/kg Gd-DTPA (triple dose). RESULTS--Nine enhancing lesions were found in seven patients (35%) using the standard dose of Gd-DTPA. The numbers of enhancing lesions increased to 13 (P = 0.03) and the number of patients with such lesions to eight (40%) on the delayed standard dose scans. On the early triple dose scans, we found 19 enhancing lesions in 10 patients (50%). The number of enhancing lesions was significantly higher (P = 0.01) than that obtained with the early standard dose. The number of enhancing lesions was 18 and the number of "active" patients 11 (55%) on the delayed triple dose scans. The enhancing areas increased progressively from the early standard dose scans to the delayed triple dose scans. The contrast ratios of the lesions detected in early standard dose scans was lower than those of lesions present in the early (P = 0.01) and delayed (P = 0.04) triple dose scans. CONCLUSIONS--More enhancing lesions were detected in patients with benign multiple sclerosis with both delay of MRI and the use of triple dose of Gd-DTPA suggesting that the amount of inflammation in the lesions of such patients is mild and heterogeneous. Images PMID:8778257

  2. THE SLEEP OF LONG-HAUL TRUCK DRIVERS

    PubMed Central

    Mitler, Merrill M.; Miller, James C.; Lipsitz, Jeffrey J.; Walsh, James K.; Wylie, C. Dennis

    2008-01-01

    Background Fatigue and sleep deprivation are important safety issues for long-haul truck drivers. Methods We conducted round-the-clock electrophysiologic and performance monitoring of four groups of 20 male truck drivers who were carrying revenue-producing loads. We compared four driving schedules, two in the United States (five 10-hour trips of day driving beginning about the same time each day or of night driving beginning about 2 hours earlier each day) and two in Canada (four 13-hour trips of late-night-to-morning driving beginning at about the same time each evening or of afternoon-to-night driving beginning 1 hour later each day). Results Drivers averaged 5.18 hours in bed per day and 4.78 hours of electrophysiologically verified sleep per day over the five-day study (range, 3.83 hours of sleep for those on the steady 13-hour night schedule to 5.38 hours of sleep for those on the steady 10-hour day schedule). These values compared with a mean (±SD) self-reported ideal amount of sleep of 7.1±1 hours a day. For 35 drivers (44 percent), naps augmented the sleep obtained by an average of 0.45±0.31 hour. No crashes or other vehicle mishaps occurred. Two drivers had undiagnosed sleep apnea, as detected by polysomnography. Two other drivers had one episode each of stage 1 sleep while driving, as detected by electroencephalography. Forty-five drivers (56 percent) had at least 1 six-minute interval of drowsiness while driving, as judged by analysis of video recordings of their faces; 1067 of the 1989 six-minute segments (54 percent) showing drowsy drivers involved just eight drivers. Conclusions Long-haul truck drivers in this study obtained less sleep than is required for alertness on the job. The greatest vulnerability to sleep or sleep-like states is in the late night and early morning. PMID:9287232

  3. Comparison of tissue injury from focused ultrasonic propulsion of kidney stones versus extracorporeal shock wave lithotripsy.

    PubMed

    Connors, Bret A; Evan, Andrew P; Blomgren, Philip M; Hsi, Ryan S; Harper, Jonathan D; Sorensen, Mathew D; Wang, Yak-Nam; Simon, Julianna C; Paun, Marla; Starr, Frank; Cunitz, Bryan W; Bailey, Michael R; Lingeman, James E

    2014-01-01

    Focused ultrasonic propulsion is a new noninvasive technique designed to move kidney stones and stone fragments out of the urinary collecting system. However, to our knowledge the extent of tissue injury associated with this technique is not known. We quantitated the amount of tissue injury produced by focused ultrasonic propulsion under simulated clinical treatment conditions and under conditions of higher power or continuous duty cycles. We compared those results to extracorporeal shock wave lithotripsy injury. A human calcium oxalate monohydrate stone and/or nickel beads were implanted by ureteroscopy in 3 kidneys of live pigs weighing 45 to 55 kg and repositioned using focused ultrasonic propulsion. Additional pig kidneys were exposed to extracorporeal shock wave lithotripsy level pulse intensity or continuous ultrasound exposure 10 minutes in duration using an ultrasound probe transcutaneously or on the kidney. These kidneys were compared to 6 treated with an unmodified Dornier HM3 lithotripter (Dornier Medical Systems, Kennesaw, Georgia) using 2,400 shocks at 120 shock waves per minute and 24 kV. Histological analysis was performed to assess the volume of hemorrhagic tissue injury created by each technique according to the percent of functional renal volume. Extracorporeal shock wave lithotripsy produced a mean ± SEM lesion of 1.56% ± 0.45% of functional renal volume. Ultrasonic propulsion produced no detectable lesion with simulated clinical treatment. A lesion of 0.46% ± 0.37% or 1.15% ± 0.49% of functional renal volume was produced when excessive treatment parameters were used with the ultrasound probe placed on the kidney. Focused ultrasonic propulsion produced no detectable morphological injury to the renal parenchyma when using clinical treatment parameters but produced injury comparable in size to that of extracorporeal shock wave lithotripsy when using excessive treatment parameters. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Continuous analysis of phosphate in a Greenland shallow ice core

    NASA Astrophysics Data System (ADS)

    Kjær, Helle Astrid; Svensson, Anders; Bigler, Matthias; Vallelonga, Paul; Kettner, Ernesto; Dahl-Jensen, Dorthe

    2010-05-01

    Phosphate is an important and sometimes limiting nutrient for primary production in the oceans. Because of deforestation and the use of phosphate as a fertilizer changes in the phosphate cycle have occurred over the last centuries. On longer time scales, sea level changes are thought to have also caused changes in the phosphate cycle. Analyzing phosphate concentrations in ice cores may help to gain important knowledge about those processes. In the present study, we attach a phosphate detection line to an existing continuous flow analysis (CFA) setup for ice core analysis at the University of Copenhagen. The CFA system is optimized for high-resolution measurements of insoluble dust particles, electrolytic melt water conductivity, and the concentrations of ammonium and sodium. For the phosphate analysis we apply a continuous and highly sensitive absorption method that has been successfully applied to determine phosphate concentrations of sea water (Zhang and Chi, 2002). A line of melt water from the CFA melt head (1.01 ml per minute) is combined with a molybdate blue reagent and an ascorbic acid buffer. An uncompleted reaction takes place in five meters of heated mixing coils before the absorption measurement at a wavelength of 710 nanometer takes place in a 2 m long liquid waveguide cell (LWCC) with an inner volume of 0.5 ml. The method has a detection limit of around 0.1 ppb and we are currently investigating a possible interference from molybdate reacting with silicates that are present in low amounts in the ice. Preliminary analysis of early Holocene samples from the NGRIP ice core show phosphate concentration values of a few ppb. In this study, we will attempt to determine past levels of phosphate in a shallow Northern Greenland firn core with an annual layer thickness of about 20 cm ice equivalent. With a melt speed of 2.5 cm ice per minute our method should allow the resolution of any seasonal variability in phosphate concentrations.

  5. The annual amount of lightning in just 20 minutes: the October 25th, 2015 super-cell thunderstorm over central Israel

    NASA Astrophysics Data System (ADS)

    Yair, Y.; Ziv, B.; Lynn, B. H.; Evgeni, K.

    2016-12-01

    An exceptionally rare Eastern Mediterranean super-cell thunderstorm occurred during the morning hours of October 25th 2015. The storm developed within the northern tip of a Red-Sea trough (extending from Sudan to the Southeastern Mediterranean Sea) off the Egyptian coastline near Alexandria and moved north-west, crossing the Israeli coast just north of Tel-Aviv at 0900 local time. Deep convective cells developed rapidly over the sea, with thunderclouds exhibiting cloud top temperatures colder than -70°C (18 km) and radar reflectivity cores > 65 dBz at 10 km. The storms were accompanied by intensive lightning activity, severe hail, downbursts, and intense rain. The super-cell subsided upon reaching the Jordan rift in eastern Israel. The super-cell caused 1 fatality, extensive flooding and agricultural damages. It also impacted the national electrical network with power outages lasting for 3 days in central Israel. More than 17,000 cloud-to-ground lightning strokes were registered by the lightning detection system of the Israeli Electrical Corporation, exceeding the annual average for the entire country. The average cloud-to-ground flash rates between 0940-0950 and 0950-1000 (local time) were greater than 436 and 430 strokes per minute respectively, exceeding the global record flash rates found in the Argentina-Paraguay border (Zipser et al., 2006). This was the most powerful thunderstorm ever observed in Israel since lightning detection became operational in 1997. Medium-range forecast models such as ECMWF and the GFS missed the timing and severity of this unusual storm. We will present a mesoscale and microphysical analysis of this event to better understand the origins and severity of this rare super-cell. WRF high-resolution simulations with lightning assimilation (Fierro et al., 2012; Lynn et al., 2015) coupled with the Dynamic Lightning Scheme (Lynn et al., 2012) will be used in order to evaluate the performance of the WRF for accurately nowcasting such events.

  6. An optimized method for the measurement of acetaldehyde by high-performance liquid chromatography.

    PubMed

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2012-03-01

    Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood, and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent, time, and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DNP) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison with AcH-DNP standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Derivatization of acetaldehyde was performed at pH 4.0 with an 80-fold molar excess of DNPH. The reaction was completed in 40 minutes at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-minute chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was <9% for intraday and <15% for interday measurements, in small volume (70 μl) plasma sampling. An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small-volume sampling of culture media and biological fluids. Copyright © 2011 by the Research Society on Alcoholism.

  7. Ocean bottom pressure observations near the source of the 2011 Tohoku earthquake

    NASA Astrophysics Data System (ADS)

    Inazu, D.; Hino, R.; Suzuki, S.; Osada, Y.; Ohta, Y.; Iinuma, T.; Tsushima, H.; Ito, Y.; Kido, M.; Fujimoto, H.

    2011-12-01

    A Mw9.0 earthquake occurred off Miyagi, northeast Japan, on 11 March 2011 (hereafter mainshock). An earthquake of M7.3, considered to be the largest foreshock of the mainshock, occurred on 9 March 2011 near the mainshock hypocenter. A suite of seismic and geodetic variations related to these earthquakes was observed by autonomous, ocean bottom pressure (OBP) gauges at multiple sites (4 sites at present) near the sources within a distance of about 100 km. This paper presents the OBP records with a focus on the earthquakes. Thanks to correcting tides, instrumental drifts, and non-tidal oceanic variations, we can detect OBP signals of tsunamis and vertical seafloor deformation of the order of centimeters with timescales of less than months. In the following we review the detected signals and how to correct the OBP data. The coseismic seafloor displacement and the tsunami accompanied by the mainshock were of the order of meters and large enough to be distinctly identified (Ito et al., 2011, GRL). Co- and post-seismic seafloor displacement and tsunami accompanied by the foreshock were of the order of centimeters which is difficult to be identified from the raw OBP records. The first evident pulses of these tsunamis in the deep sea have durations (periods) of ~20 minutes and ~10 minutes, for the mainshock and the foreshock, respectively. Amounts of seafloor vertical displacement due to post-mainshock deformation reached a few tens of centimeters in two months. It is worth noting that elevation and depression of seafloor were detected at rates of a couple of centimeters in a day after the largest foreshock. The seafloor displacement of centimeters between the largest foreshock and the mainshock can be reasonably identified after correcting non-tidal oceanic variations. The oceanic variations are simulated by a barotropic ocean model driven by atmospheric disturbances (Inazu et al., 2011, Ann. Rep. Earth Simulator Center 2011). The model enables residual OBP time series of non-tidal oceanic variations off Miyagi to be reduced by less than 2 cm. In order to accurately detect signals of centimeters, detiding had better be carefully done analyzing in-situ data rather than using existing ocean tide models such as NAO.99Jb and FES2004. A BAYTAP-G program was used in the present study. Instrumental drifts are modeled by a popularly used, linear and exponential form (Watts and Kontoyiannis, 1990, J. Atmos. Oceanic Tech.). Seismological interpretations of the detected OBP signals of the seafloor displacement and the tsunamis will be demonstrated in the separate papers presented in this meeting.

  8. Biofluidic Transport and Molecular Recognition in Polymer Microdevices

    DTIC Science & Technology

    2005-04-29

    flexible membrane separating the particles and reservoir. B. Using photopolymerizable wires, an electrolysis pump was fabricated on a microdevice. It...Antigen detection was accomplished by grafting the approximate antibody or sensing compound via acrylation and polymerization to the surface. Figure 14...were detected with assay times of approximately 10 minutes. Figure 15 shows detection data for a compound (glucagon) that is impossible to detect by

  9. Influence of time, toothpaste and saliva in the retention of Streptococcus mutans and Streptococcus sanguinis on different toothbrushes

    PubMed Central

    SCHMIDT, Julia Caroline; BUX, Miriam; FILIPUZZI-JENNY, Elisabeth; KULIK, Eva Maria; WALTIMO, Tuomas; WEIGER, Roland; WALTER, Clemens

    2014-01-01

    Objectives The intraoral transmission of cariogenic and periodontopathogenic species seems to be facilitated by contaminated toothbrushes and other oral hygiene devices. The aim of this investigation was to analyze the in vitro retention and survival rate of Streptococcus mutans and Streptococcus sanguinis on different toothbrushes. The impacts of human saliva and antimicrobial toothpaste on these parameters were further evaluated. Material and Methods Part I: Four toothbrushes (Colgate 360°, Curaprox CS5460 ultra soft, elmex InterX, Trisa Flexible Head3) were contaminated by S. mutans DSM 20523 or S. sanguinis DSM 20068 suspensions for three minutes. Bacteria were removed from the toothbrushes after either three minutes (T0) or 24 hours (T24) of dry storage and grown on Columbia blood agar plates for the quantification of colony-forming units (CFUs). Part II: The effects of saliva from a caries-active or a caries-inactive person and of toothpaste containing 0.12% chlorhexidine digluconate were also tested. Results Part I: After three minutes of dry storage, approximately one percent of the bacteria were still detectable on the toothbrushes. After 24 hours, S. sanguinis exhibited a more pronounced decrease in viable cell numbers compared with S. mutans but the differences were not significant (Kruskal-Wallis test, p>0.05). Part II: The addition of human saliva from a caries-active or caries-inactive person slightly increased the retention of both streptococcal species at T0. The use of toothpaste had no influence on the amount of viable streptococci at T0, but it reduced the microbial load after 24 hours of storage. There were only slight nonsignificant differences (p>0.05) between the four toothbrushes. Conclusions In vitro bacterial retention and survival of S. sanguinis and S. mutans on different toothbrushes occurred. Within the limitations of this study, the use of human saliva or an antimicrobial toothpaste did not lead to significant differences in the microbial load on toothbrushes. PMID:25025554

  10. Digital PCR analysis of circulating nucleic acids.

    PubMed

    Hudecova, Irena

    2015-10-01

    Detection of plasma circulating nucleic acids (CNAs) requires the use of extremely sensitive and precise methods. The commonly used quantitative real-time polymerase chain reaction (PCR) poses certain technical limitations in relation to the precise measurement of CNAs whereas the costs of massively parallel sequencing are still relatively high. Digital PCR (dPCR) now represents an affordable and powerful single molecule counting strategy to detect minute amounts of genetic material with performance surpassing many quantitative methods. Microfluidic (chip) and emulsion (droplet)-based technologies have already been integrated into platforms offering hundreds to millions of nanoliter- or even picoliter-scale reaction partitions. The compelling observations reported in the field of cancer research, prenatal testing, transplantation medicine and virology support translation of this technology into routine use. Extremely sensitive plasma detection of rare mutations originating from tumor or placental cells among a large background of homologous sequences facilitates unraveling of the early stages of cancer or the detection of fetal mutations. Digital measurement of quantitative changes in plasma CNAs associated with cancer or graft rejection provides valuable information on the monitoring of disease burden or the recipient's immune response and subsequent therapy treatment. Furthermore, careful quantitative assessment of the viral load offers great value for effective monitoring of antiviral therapy for immunosuppressed or transplant patients. The present review describes the inherent features of dPCR that make it exceptionally robust in precise and sensitive quantification of CNAs. Moreover, I provide an insight into the types of potential clinical applications that have been developed by researchers to date. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Simultaneous detection of bovine and porcine DNA in pharmaceutical gelatin capsules by duplex PCR assay for Halal authentication.

    PubMed

    Nikzad, Jafar; Shahhosseini, Soraya; Tabarzad, Maryam; Nafissi-Varcheh, Nastaran; Torshabi, Maryam

    2017-02-14

    In the pharmaceutical industry, hard- and soft-shelled capsules are typically made from gelatin, commonly derived from bovine and porcine sources. To ensure that pharmaceutical products comply with halal regulations in Muslim countries (no porcine products allowed), development of a valid, reliable, quick, and most importantly, cost-effective tests are of utmost importance. We developed a species-specific duplex polymerase chain reaction (PCR) assay targeting 149 bp porcine and 271 bp bovine mitochondrial DNA (mtDNA) to simultaneously detect both porcine and bovine DNA (in one reaction at the same time) in gelatin. Some additional simplex PCR tests (targeting 126 bp bovine and 212 bp porcine mtDNA) and real-time PCR using a commercially available kit (for identification of porcine DNA) were used to verify the selectivity and sensitivity of our duplex PCR. After optimization of DNA extraction and PCR methods, hard/soft pharmaceutical gelatin capsules (containing drug) were tested for the presence of porcine and/or bovine DNA. Duplex PCR detected the presence of as little as 0.1% porcine DNA, which was more accurate than the commercially available kit. Of all gelatin capsules tested (n = 24), 50% contained porcine DNA (pure porcine gelatin alone or in combination with bovine gelatin). Duplex PCR presents an easy-to-follow, quick, low-cost and reliable method to simultaneously detect porcine and bovine DNAs (>100 bp) in minute amounts in highly processed gelatin-containing pharmaceutical products (with a 0.1% sensitivity for porcine DNA) which may be used for halal authentication. Simultaneous detection of porcine and bovine DNA in gelatin capsules by duplex PCR.

  12. Metal oxide nanoparticles for latent fingerprint visualization and analysis of small drug molecules using surface-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Amin, Mohamed O; Madkour, Metwally; Al-Hetlani, Entesar

    2018-05-17

    We explored the applicability of different metal oxide nanoparticles (NPs; ZnO, TiO 2 , Fe 2 O 3 , and CeO 2 ) for the optical imaging and mass spectrometric determination of small drug molecules in latent fingerprints (LFPs). Optical imaging was achieved using a dry method-simply dusting the LFPs with a minute amount of NP powder-and still images were captured using a digital microscope and a smartphone camera. Mass spectrometric determination was performed using the NPs as substrates for surface-assisted laser desorption ionization/mass spectrometry (SALDI-MS), which enabled the detection of small drug molecules with high signal intensities. The reproducibility of the results was studied by calculating the % error, SD, and RSD in the results obtained with the various metal oxide NPs. Collectively, the findings showed that using NPs can boost the intensity of the detected signal while minimizing background noise which is an issue predominantly associated with conventional organic matrices of MALDI-MS. Among the four metal oxide NPs, utilization of the Fe 2 O 3 NPs led to the best SALDI performance and the highest detection sensitivity for the analytes of interest. The study was then extended by investigating the influence of time elapsed since the generation of the LFP on the detection of drug molecules in the LFP. The results demonstrated that this method allows the analysis of drug molecules after as long as one week at low and intermediate temperatures (0 and 25 °C). Therefore, the SALDI analysis of small molecules using inorganic NPs, which can be implemented in forensic laboratories for screening and detection purposes, as a powerful alternative to the use of organic matrices. Graphical abstract ᅟ.

  13. Unsupervised online classifier in sleep scoring for sleep deprivation studies.

    PubMed

    Libourel, Paul-Antoine; Corneyllie, Alexandra; Luppi, Pierre-Hervé; Chouvet, Guy; Gervasoni, Damien

    2015-05-01

    This study was designed to evaluate an unsupervised adaptive algorithm for real-time detection of sleep and wake states in rodents. We designed a Bayesian classifier that automatically extracts electroencephalogram (EEG) and electromyogram (EMG) features and categorizes non-overlapping 5-s epochs into one of the three major sleep and wake states without any human supervision. This sleep-scoring algorithm is coupled online with a new device to perform selective paradoxical sleep deprivation (PSD). Controlled laboratory settings for chronic polygraphic sleep recordings and selective PSD. Ten adult Sprague-Dawley rats instrumented for chronic polysomnographic recordings. The performance of the algorithm is evaluated by comparison with the score obtained by a human expert reader. Online detection of PS is then validated with a PSD protocol with duration of 72 hours. Our algorithm gave a high concordance with human scoring with an average κ coefficient > 70%. Notably, the specificity to detect PS reached 92%. Selective PSD using real-time detection of PS strongly reduced PS amounts, leaving only brief PS bouts necessary for the detection of PS in EEG and EMG signals (4.7 ± 0.7% over 72 h, versus 8.9 ± 0.5% in baseline), and was followed by a significant PS rebound (23.3 ± 3.3% over 150 minutes). Our fully unsupervised data-driven algorithm overcomes some limitations of the other automated methods such as the selection of representative descriptors or threshold settings. When used online and coupled with our sleep deprivation device, it represents a better option for selective PSD than other methods like the tedious gentle handling or the platform method. © 2015 Associated Professional Sleep Societies, LLC.

  14. Detection of mental stress due to oral academic examination via ultra-short-term HRV analysis.

    PubMed

    Castaldo, R; Xu, W; Melillo, P; Pecchia, L; Santamaria, L; James, C

    2016-08-01

    Mental stress may cause cognitive dysfunctions, cardiovascular disorders and depression. Mental stress detection via short-term Heart Rate Variability (HRV) analysis has been widely explored in the last years, while ultra-short term (less than 5 minutes) HRV has been not. This study aims to detect mental stress using linear and non-linear HRV features extracted from 3 minutes ECG excerpts recorded from 42 university students, during oral examination (stress) and at rest after a vacation. HRV features were then extracted and analyzed according to the literature using validated software tools. Statistical and data mining analysis were then performed on the extracted HRV features. The best performing machine learning method was the C4.5 tree algorithm, which discriminated between stress and rest with sensitivity, specificity and accuracy rate of 78%, 80% and 79% respectively.

  15. Capacitive system detects and locates fluid leaks

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Electronic monitoring system automatically detects and locates minute leaks in seams of large fluid storage tanks and pipelines covered with thermal insulation. The system uses a capacitive tape-sensing element that is adhesively bonded over seams where fluid leaks are likely to occur.

  16. [Hypobaric chamber as a test of the aircrew of Russain Air Forces].

    PubMed

    Shishov, A A; Olenev, N I; Shishkin, A N; Filatov, V N

    2014-04-01

    Authors research clinical medical importance of hypobaric ascends to an attitude of 5000 meters for 20 minutes for detection of latent forms of diseases and assessment of professional health and ascends to an attitude of 5000 and 6000 meters for 5 minutes when performing psychophysiological training for high altitude flying. According to test of 1326 pilots of Russian Air Forces, including pilots with different diseases, hypobaric ascends showed high diagnostic effectiveness for the professional health assessment. By using of both methods it was revealed that frequency of detection of decreased tolerance to hypoxia is the same (in average in 2,7 and 3,1% of total number of patients). By ascends in 38 patients (2,9%) was revealed decreased tolerance to hypoxia of medium level. It indicated about low functional state and space capacity of pilots. It was proved that hypobaric ascends of 5000 and 6000 meters for 5 minutes could be considered as an effective method of checkup of aircrew for the aviation physical examination.

  17. Photothermal method for in situ microanalysis of the chemical composition of coal samples

    DOEpatents

    Amer, Nabil M.

    1986-01-01

    Successive minute regions (13) along a scan path on a coal sample (11) are individually analyzed, at a series of different depths if desired, to determine chemical composition including the locations, sizes and distributions of different maceral inclusions (12). A sequence of infrared light pulses (17) of progressively changing wavelengths is directed into each minute region (13) and a probe light beam (22) is directed along the sample surface (21) adjacent the region (13). Infrared wavelengths at which strong absorption occurs in the region (13) are identified by detecting the resulting deflections (.phi.) of the probe beam (22) caused by thermally induced index of refraction changes in the air or other medium (19) adjacent the region (13). The detected peak absorption wavelengths are correlated with known characteristic peak absorption wavelengths of specific coal constituents to identify the composition of each such minute region (13) of the sample (11). The method enables rapid, convenient and non-destructive analyses of coal specimens to facilitate mining, processing and utilization of coals.

  18. Photothermal method for in situ microanalysis of the chemical composition of coal samples

    DOEpatents

    Amer, N.M.

    1983-10-25

    Successive minute regions along a scan path on a coal sample are individually analyzed, at a series of different depths if desired, to determine chemical composition including the locations, sizes and distributions of different maceral inclusions. A sequence of infrared light pulses of progressively changing wavelengths is directed into each minute region and a probe light beam is directed along the sample surface adjacent the region. Infrared wavelengths at which strong absorption occurs in the region are identified by detecting the resulting deflections of the probe beam caused by thermally induced index of refraction changes in the air or other medium adjacent the region. The detected peak absorption wavelengths are correlated with known characteristic peak absorption wavelengths of specific coal constituents to identify the composition of each such minute region of the sample. The method enables rapid, convenient and non-destructive analyses of coal specimens to facilitate mining, processing and utilization of coals. 2 figures.

  19. Five-minute P Modes Detected in Doppler Shift Measurement on Alpha Centauri

    NASA Technical Reports Server (NTRS)

    Fossat, E.; Grec, G.; Gelly, B.

    1984-01-01

    A spectrophotometer using the principle of optical resonance spectroscopy, designed for the goal of identifying radial and weakly non radial eigenmodes in the five minute range in the case of stars, is discussed. The conclusion of the first test of this new instrument was that if the observation can be photon noise limited (i.e., in total absence of any instrumental source of noise), the five-minute solar oscillation could still be detected by removing the Sun far enough for its magnitude to become zero or one. Such a situation is very closely represented by the observation of Alpha Centauri A, because it is a G2 V star, very similar to the Sun, with a mass of 1.1 in solar unit. Six nights were granted to this program on a 3.6m telescope, from 22 to 28 May 1983. Two and half nights provided over 20 hours of data of photometric quality good enough for analysis.

  20. The Earth System Science Pathfinder VOLCAM Volcanic Hazard Mission

    NASA Technical Reports Server (NTRS)

    Krueger, Arlin J.

    1999-01-01

    The VOLCAM mission is planned for research on volcanic eruptions and as a demonstration of a satellite system for measuring the location and density of volcanic eruption clouds for use in mitigating hazards to aircraft by the operational air traffic control systems. A requirement for 15 minute time resolution is met by flight as payloads of opportunity on geostationary satellites. Volcanic sulfur dioxide and ash are detected using techniques that have been developed from polar orbiting TOMS (UV) and AVHRR (IR) data. Seven band UV and three band IR filter wheel cameras are designed for continuous observation of the full disk of the earth with moderate (10 - 20 km) ground resolution. This resolution can be achieved with small, low cost instruments but is adequate for discrimination of ash and sulfur dioxide in the volcanic clouds from meteorological clouds and ozone. The false alarm rate is small through use of sulfur dioxide as a unique tracer of volcanic clouds. The UV band wavelengths are optimized to detect very small sulfur dioxide amounts that are present in pre-eruptive outgassing of volcanoes. The system is also capable of tracking dust and smoke clouds, and will be used to infer winds at tropopause level from the correlation of total ozone with potential vorticity.

  1. Initiation of Coronal Mass Ejections by Tether-Cutting Reconnection

    NASA Technical Reports Server (NTRS)

    Moore, Ronald L.; Sterling, Alphonse C.; Falconer, David A.; Six, N. Frank (Technical Monitor)

    2002-01-01

    We present and interpret examples of the eruptive motion and flare brightening observed in the onset of magnetic explosions that produce coronal mass ejections. The observations are photospheric magnetograms and sequences of coronal and/or chromospheric images. In our examples, the explosion is apparently driven by the ejective eruption of a sigmoidal sheared-field flux rope from the core of an initially closed bipole. This eruption is initiated (triggered and unleashed) by reconnection located either (1) internally, low in the sheared core field, or (2) externally, at a magnetic null above the closed bipole. The internal reconnection is commonly called 'tether-cutting" reconnection, and the external reconnection is commonly called "break-out' reconnection. We point out that break-out reconnection amounts to external tether cutting. In one example, the eruptive motion of the sheared core field starts several minutes prior to any detectable brightening in the coronal images. We suggest that in this case the eruption is triggered by internal tether-cutting reconnection that at first is too slow and/or too localized to produce detectable heating in the coronal images. This work is supported by NASA's Office of Space Science through its Solar & Heliospheric Physics Supporting Research & Technology program and its Sun-Earth Connection Guest Investigator program.

  2. A Theoretical Study of Love Wave Sensors Based on ZnO–Glass Layered Structures for Application to Liquid Environments

    PubMed Central

    Caliendo, Cinzia; Hamidullah, Muhammad

    2016-01-01

    The propagation of surface acoustic Love modes along ZnO/glass-based structures was modeled and analysed with the goal of designing a sensor able to detect changes in the environmental parameters, such as liquid viscosity changes and minute amounts of mass supported in the viscous liquid medium. Love mode propagation was modeled by numerically solving the system of coupled electro-mechanical field equations and Navier–Stokes equations. The phase and group velocities and the attenuation of the acoustic wave propagating along the 30° tilted c-axis ZnO/glass structure contacting a viscous non-conductive liquid were calculated for different ZnO guiding layer thicknesses, added mass thicknesses, and liquid viscosity and density. The three sensor responses, i.e., the wave phase and group velocity, and attenuation changes are calculated for different environmental parameters and related to the sensor velocity and attenuation sensitivities. The resulted sensitivities to liquid viscosity and added mass were optimized by adjusting the ZnO guiding layer thickness corresponding to a sensitivity peak. The present analysis is valuable for the manufacture and application of the ZnO-glass structure Love wave sensors for the detection of liquid properties, such as viscosity, density and mass anchored to the sensor surface. PMID:27918419

  3. Immune protection against reinfection with nonprimate hepacivirus

    PubMed Central

    Pfaender, Stephanie; Walter, Stephanie; Grabski, Elena; Todt, Daniel; Bruening, Janina; Romero-Brey, Inés; Gather, Theresa; Brown, Richard J. P.; Hahn, Kerstin; Puff, Christina; Pfankuche, Vanessa M.; Hansmann, Florian; Postel, Alexander; Becher, Paul; Thiel, Volker; Kalinke, Ulrich; Wagner, Bettina; Bartenschlager, Ralf; Baumgärtner, Wolfgang; Feige, Karsten; Pietschmann, Thomas; Cavalleri, Jessika M. V.; Steinmann, Eike

    2017-01-01

    Hepatitis C virus (HCV) displays a restricted host species tropism and only humans and chimpanzees are susceptible to infection. A robust immunocompetent animal model is still lacking, hampering mechanistic analysis of virus pathogenesis, immune control, and prophylactic vaccine development. The closest homolog of HCV is the equine nonprimate hepacivirus (NPHV), which shares similar features with HCV and thus represents an animal model to study hepacivirus infections in their natural hosts. We aimed to dissect equine immune responses after experimental NPHV infection and conducted challenge experiments to investigate immune protection against secondary NPHV infections. Horses were i.v. injected with NPHV containing plasma. Flow cytometric analysis was used to monitor immune cell frequencies and activation status. All infected horses became viremic after 1 or 2 wk and viremia could be detected in two horses for several weeks followed by a delayed seroconversion and viral clearance. Histopathological examinations of liver biopsies revealed mild, periportally accentuated infiltrations of lymphocytes, macrophages, and plasma cells with some horses displaying subclinical signs of hepatitis. Following viral challenge, an activation of equine immune responses was observed. Importantly, after a primary NPHV infection, horses were protected against rechallenge with the homologous as well as a distinct isolate with only minute amounts of circulating virus being detectable. PMID:28275093

  4. Effects of the amount of rice in meals on postprandial blood pressure in older people with postprandial hypotension: a within-subjects design.

    PubMed

    Son, Jung Tae; Lee, Eunjoo

    2015-08-01

    To determine the effect of the amount of rice carbohydrates consumed during mealtime on the extent of decrease in postprandial blood pressure in older people with postprandial hypotension. The incidence of postprandial hypotension is as high as 74% in older people with hypertension. A within-subjects repeated measures design was used. Thirty-nine older people in nursing homes received a full serving and a half-serving of rice on two separate days, in random order blood pressure and heart rate were measured before each meal and every 15 minutes for a total of 120 minutes after each meal. Data were analysed using repeated measures analysis of variance and the paired t-test with a Bonferroni adjustment using IBM spss version 19.0. The control and intervention conditions yielded significantly different patterns in systolic blood pressure and diastolic blood pressure. Postprandial hypotension was less frequent under the intervention condition; however, decrease in rice intake did not significantly affect heart rate. Reducing the amount of rice intake per meal prevents postprandial blood pressure decreases in the older people. Small and frequent meals with decreased carbohydrate content are recommended to prevent postprandial hypotension and its complications in the older people. Patients, dieticians and caregivers of older patients should be aware of the importance of diet, especially of decreasing the amount of carbohydrate in a meal. Smaller and more frequent meals are recommended for older people to slow gastric emptying. © 2015 John Wiley & Sons Ltd.

  5. Effect of eliminating the residual fluoride gel on titanium bracket corrosion.

    PubMed

    Khoury, Elie S; Abboud, Maher; Bassil-Nassif, Nayla; Bouserhal, Joseph

    2011-09-01

    Fluoride ions, in long-term applications on titanium brackets, cause their corrosion. Fluoride gel used for caries prevention during orthodontic treatment has a very high concentration in fluoride ions, and therefore has the potential for causing bracket corrosion. The main aim of this study was to determine the effect of eliminating the residual fluoride gel, by rinsing it, on the corrosion of titanium brackets. The secondary aim was to evaluate the corrosion of titanium brackets in the presence of fluoride gel. One hundred titanium brackets were divided into five groups of 20 brackets each. Group 1 being the control group, the rest of the groups were immersed in fluoride gel: Group 2 for 4 minutes and kept for 30 minutes with the residual fluoride gel on; Group 3 for 4 minutes followed by immediate water rinsing; Group 4 for 12 minutes and kept for 90 minutes with the residual fluoride gel on and Group 5 for 12 minutes followed by immediate water rinsing. All groups were rinsed then dried, for 20 hours, using Silica gel in a desiccator maintained at 37°C before testing. Gravimetrical results and SEM analysis showed no significant difference between Groups 2, 3 and 5 compared to each other and to the control group. Only Group 4 showed significant weight loss and pitting corrosion in four of the 20 brackets. In sliding resistance, no significant difference was detected between any of the groups. Short time applications of fluoride gel do not affect sliding resistance of titanium brackets. No titanium corrosion was detected for one application of concentrated fluoride gel and some brackets showed pitting corrosion for three applications. The rinsing of residual fluoride gel eliminates completely the risk of bracket corrosion. Copyright © 2011 CEO. Published by Elsevier Masson SAS. All rights reserved.

  6. Comparison of the anti-apoptotic effects of 15- and 35-minute suspended moxibustion after focal cerebral ischemia/reperfusion injury.

    PubMed

    Xiao, Ai-Jiao; He, Lin; Ouyang, Xin; Liu, Jie-Min; Chen, Ming-Ren

    2018-02-01

    Heat-sensitive suspended moxibustion has a neuroprotective effect against focal cerebral ischemia/reperfusion injury, but the underlying mechanisms remain unclear. The duration of heat-sensitive suspended moxibustion (usually from 30 minutes to 1 hour) is longer than traditional suspended moxibustion (usually 15 minutes). However, the effects of 15- and 35-minute suspended moxibustion in rats with cerebral ischemia/reperfusion injury are poorly understood. In this study, we performed 15- or 35-minute suspended moxibustion at acupoint Dazhui (GV14) in an adult rat model of focal cerebral ischemia/reperfusion injury. Infarct volume was evaluated with the 2,3,5-triphenyltetrazolium chloride assay. Histopathological changes and neuronal apoptosis at the injury site were assessed by hematoxylin-eosin staining and terminal deoxynucleotidyl transferase dUTP nick end labeling assay. Caspase-9 and caspase-3 expression at the injury site was detected using immunofluorescent staining. Bax and Bcl-2 expression at the injury site was assessed using western blot assay. In the 35-minute moxibustion group, infarct volume was decreased, neuronal apoptosis was reduced, caspase-9, caspase-3 and Bax expression was lower, and Bcl-2 expression was increased, compared with the 15-minute moxibustion group. Our findings show that 35-minute moxibustion has a greater anti-apoptotic effect than 15-minute moxibustion after focal cerebral ischemia/reperfusion injury.

  7. An Analysis on the Detection of Biological Contaminants Aboard Aircraft

    PubMed Central

    Hwang, Grace M.; DiCarlo, Anthony A.; Lin, Gene C.

    2011-01-01

    The spread of infectious disease via commercial airliner travel is a significant and realistic threat. To shed some light on the feasibility of detecting airborne pathogens, a sensor integration study has been conducted and computational investigations of contaminant transport in an aircraft cabin have been performed. Our study took into consideration sensor sensitivity as well as the time-to-answer, size, weight and the power of best available commercial off-the-shelf (COTS) devices. We conducted computational fluid dynamics simulations to investigate three types of scenarios: (1) nominal breathing (up to 20 breaths per minute) and coughing (20 times per hour); (2) nominal breathing and sneezing (4 times per hour); and (3) nominal breathing only. Each scenario was implemented with one or seven infectious passengers expelling air and sneezes or coughs at the stated frequencies. Scenario 2 was implemented with two additional cases in which one infectious passenger expelled 20 and 50 sneezes per hour, respectively. All computations were based on 90 minutes of sampling using specifications from a COTS aerosol collector and biosensor. Only biosensors that could provide an answer in under 20 minutes without any manual preparation steps were included. The principal finding was that the steady-state bacteria concentrations in aircraft would be high enough to be detected in the case where seven infectious passengers are exhaling under scenarios 1 and 2 and where one infectious passenger is actively exhaling in scenario 2. Breathing alone failed to generate sufficient bacterial particles for detection, and none of the scenarios generated sufficient viral particles for detection to be feasible. These results suggest that more sensitive sensors than the COTS devices currently available and/or sampling of individual passengers would be needed for the detection of bacteria and viruses in aircraft. PMID:21264266

  8. The accuracy of eyelid movement parameters for drowsiness detection.

    PubMed

    Wilkinson, Vanessa E; Jackson, Melinda L; Westlake, Justine; Stevens, Bronwyn; Barnes, Maree; Swann, Philip; Rajaratnam, Shantha M W; Howard, Mark E

    2013-12-15

    Drowsiness is a major risk factor for motor vehicle and occupational accidents. Real-time objective indicators of drowsiness could potentially identify drowsy individuals with the goal of intervening before an accident occurs. Several ocular measures are promising objective indicators of drowsiness; however, there is a lack of studies evaluating their accuracy for detecting behavioral impairment due to drowsiness in real time. In this study, eye movement parameters were measured during vigilance tasks following restricted sleep and in a rested state (n = 33 participants) at three testing points (n = 71 data points) to compare ocular measures to a gold standard measure of drowsiness (OSLER). The utility of these parameters for detecting drowsiness-related errors was evaluated using receiver operating characteristic curves (ROC) (adjusted by clustering for participant) and identification of optimal cutoff levels for identifying frequent drowsiness-related errors (4 missed signals in a minute using OSLER). Their accuracy was tested for detecting increasing frequencies of behavioral lapses on a different task (psychomotor vigilance task [PVT]). Ocular variables which measured the average duration of eyelid closure (inter-event duration [IED]) and the ratio of the amplitude to velocity of eyelid closure were reliable indicators of frequent errors (area under the curve for ROC of 0.73 to 0.83, p < 0.05). IED produced a sensitivity and specificity of 71% and 88% for detecting ≥ 3 lapses (PVT) in a minute and 100% and 86% for ≥ 5 lapses. A composite measure of several eye movement characteristics (Johns Drowsiness Scale) provided sensitivities of 77% and 100% for detecting 3 and ≥ 5 lapses in a minute, with specificities of 85% and 83%, respectively. Ocular measures, particularly those measuring the average duration of episodes of eye closure are promising real-time indicators of drowsiness.

  9. [How do Norwegian dermatologists keep themselves professionally updated?].

    PubMed

    Gjersvik, P J; Nylenna, M; Aasland, O G

    2001-12-10

    We have explored continuing medical education among Norwegian dermatologists, especially their use of medical journals and the Internet. In April 2001, a questionnaire was sent to 170 dermatologists, including junior doctors in specialist training. 129 questionnaires (76%) were returned, of which 16 were excluded from the analysis. Mean time used per week reading articles in medical journals was 149 minutes (95% confidence interval (CI) 129-168 minutes). 90% of the respondents had Internet access at work and/or at home. Hospital consultants used the Internet for medical purposes for significantly more time per week than doctors in private practice (146 minutes (CI 98-195 minutes) versus 72 minutes (CI 52-93 minutes)). More hospital doctors had difficulties in getting or taking time off to attend courses and congresses (p < 0.01) and with financial costs (p < 0.001) than those in private practice. Most dermatologists found the paper version of journals (88%) and courses and congresses (79%) to be important for their continuing medical education, while fewer found medical databases on the Internet (57%) and the Internet version of journals (35%) to be so. In a logistic regression model, fewer private practitioners than hospital doctors (p = 0.011) and more female than male doctors (p = 0.014) had a feeling of insufficiency in regard to the increasing amount of medical information. The Internet has become part of the professional life of most Norwegian dermatologists, but has so far not replaced traditional forms of continuing medical education.

  10. The Effects of Professors' Race and Gender on Student Evaluations and Performance

    ERIC Educational Resources Information Center

    Basow, Susan A.; Codos, Stephanie; Martin, Julie L.

    2013-01-01

    This experimental study examined the effects of professor gender, professor race, and student gender on student ratings of teaching effectiveness and amount learned. After watching a three-minute engineering lecture presented by a computer-animated professor who varied by gender and race (African American, White), female and male undergraduates…

  11. 30 CFR 75.1107-10 - High expansion foam devices; minimum capacity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High expansion foam devices; minimum capacity... foam devices; minimum capacity. (a) On unattended underground equipment the amount of water delivered as high expansion foam for a period of approximately 20 minutes shall be not less than 0.06 gallon...

  12. 30 CFR 75.1107-10 - High expansion foam devices; minimum capacity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false High expansion foam devices; minimum capacity... foam devices; minimum capacity. (a) On unattended underground equipment the amount of water delivered as high expansion foam for a period of approximately 20 minutes shall be not less than 0.06 gallon...

  13. Modified and improved sleep monitoring display console

    NASA Technical Reports Server (NTRS)

    Frost, J. D., Jr.

    1972-01-01

    An outline is given of a sleep monitoring display console capable of simultaneously displaying: (1) the visible current sleep stage of each subject, (2) a cumulative, numerical display (in hours and minutes) of the total amount of time the subject spends in each stage, and (3) a stepwise, graphic recording of subject's sleep stage versus time.

  14. 21 CFR 522.2470 - Tiletamine hydrochloride and zolazepam hydrochloride for injection.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... dogs for restraint and minor procedures of short duration (30 minutes) requiring mild to moderate analgesia. (2) Amount. Expressed as milligrams of the drug combination: (i) In healthy dogs: An initial intramuscular dosage of 3 to 4.5 milligrams per pound of body weight for diagnostic purposes; 4.5 to 6...

  15. Oil content in seeds of the NPGS jojoba (Simmondsia chinensis) germplasm collection

    USDA-ARS?s Scientific Manuscript database

    Jojoba, Simmondsia chinensis, (Link) Schneider is a shrub native to warm and arid land regions of North and Latin America. Its seeds contain vegetable oil composed of long (C20-22), straight-chain liquid wax of non-glyceride esters. Minute amounts of triglycerides in its composition make the oil a l...

  16. Effectiveness of a summer healthy lifestyle program for promoting moderate-vigorous activity in minority girls

    USDA-ARS?s Scientific Manuscript database

    Current physical activity guidelines recommend that children engage in at least 60 minutes of moderate to vigorous activity each day. However, there is little research on what types of activities are most effective for facilitating this amount of activity. To assess which physical activities elicite...

  17. Carbohydrate Strategies for Injury Prevention

    PubMed Central

    Schlabach, Gretchen

    1994-01-01

    Prevention of injury involves identifying risk factors that would predispose one to injury and developing strategies to attenuate or eliminate their presence. Because muscle glycogen depletion is associated with fatigue and injury, it should be treated as a possible risk factor. Muscle glycogen stores are derived almost entirely from carbohydrate intake. Because there is a limited capacity to store muscle glycogen, and because muscle glycogen is the predominant fuel in exercise of moderate to severe intensity, the nutritional focus should be on carbohydrate consumption. Easy-to-follow nutritional strategies should be employed that will maximize muscle glycogen stores and delay the onset of fatigue. Individuals involved in activities lasting less than 60 minutes need to consume an adequate amount of carbohydrate daily and a pre-event meal before the start of the activity. However, individuals participating in activities longer than 60 minutes or participating in activities requiring repeated bouts of high intensity exercise need to: 1) consume an adequate amount of carbohydrate daily, 2) practice carbohydrate loading, 3) consume the pre-event meal, and 4) ingest carbohydrates immediately before, during, and after the activity. PMID:16558287

  18. Chapter IX. Bedtime Routines in Toddlerhood: Prevalence, Consistency, and Associations with Nighttime Sleep

    PubMed Central

    Staples, Angela D.; Bates, John E.; Petersen, Isaac T.

    2016-01-01

    The ability to transition from wakefulness to sleep is one of the most important tasks in the development of sleep during early childhood. Although establishing regular bedtime routines for children with sleep problems can be clinically effective in reducing the number of signaled night awakenings and increasing amounts of sleep, it is unclear whether a regular bedtime routine would be associated with either the frequency of signaled night awakenings or nightly sleep minutes in a non-clinical sample of children. This study examined the role of a regular bedtime routine on the development of sleep regulation and consolidation in a community sample of young children. Adherence to a bedtime routine was concurrently associated with a greater amount of nightly sleep at 36 and 42 months. In addition, adherence to a bedtime routine predicted an increase in nightly sleep minutes over a six-month period. Finally, this study demonstrated that adherence to a bedtime routine was particularly supportive of developmental gains for children of mothers who used consistent parenting practices during the day. PMID:25704740

  19. Sauna-Induced Body Mass Loss in Young Sedentary Women and Men

    PubMed Central

    Podstawski, Robert; Boraczyński, Tomasz; Boraczyński, Michał

    2014-01-01

    The aim of the study was to evaluate the relationship between body mass index (BMI) and body mass loss (BML) induced by thermal stress in a dry sauna. The study was conducted on a group of 674 sedentary students, 326 women and 348 men aged 19-20. The correlations between BMI scores and BML were determined. The subjects were placed in supine position in a dry sauna for two sessions of 10 minutes each with a 5-minute break. The influence of BMI on the amount of BML in the sauna was determined by nonlinear stepwise regression. The smallest BML was noted in underweight subjects; students with normal weight lost more weight, whereas the greatest BML was reported in overweight and obese subjects. Persons with a high BMI are at higher risk of dehydration, and they should pay particular attention to replenishing fluids during a visit to the sauna. The proposed equations for calculating BML based on a person's BMI can be useful in estimating the amount of fluids that should be replenished by both men and women during a visit to a dry sauna. PMID:25614882

  20. X-radiography of trace fossils in limestones and dolostones from the Jurassic Smackover Formation, south Alabama

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esposito, R.A.; Castleman, S.P.; King, D.T. Jr.

    X-radiography has been useful in studying biogenic sedimentary structures in unconsolidated sediments but the technique has not been applied often to the study of hard carbonate rock. The authors have applied x-radiography to the study of the lower part of the Smackover to enhance the complete petrologic description of the rock. The lower Smackover has many dense micrite intervals and intervals of monotonous, thin graded beds. Parts of the lower Smackover is also dolomitized. None of the above rocks contains significant amount of skeletal debris and trace fossils are not generally obvious in an etched slab of core. In limestone,more » they have detected well-preserved trace fossils by x-radiography, however. The dolostones show no traces using our method. In limestones, the traces are marked by minute amounts of finely divided iron sulfides. This causes a slight density difference resulting in greater x-ray absorption. They recognize two main trace-fossil types: a Thalassinoides best seen in slabs cut parallel to bedding and a Zoophycos best seen in slabs cut perpendicular to bedding. The technique requires a slab cut 8 mm thick with parallel flat surfaces and a medical x-ray unit using accelerating voltages of 66 kV and 10 mas. Traces are most successfully imaged on industrial-quality films.« less

  1. Potential health and environmental issues of mercury-contaminated amalgamators.

    PubMed

    Roberts, H W; Leonard, D; Osborne, J

    2001-01-01

    Dental amalgamators may become contaminated internally with metallic mercury. This contamination may result from mercury leakage from capsules during trituration or from the long-term accrual from microscopic exterior contaminants that result from the industrial assembly process. The potential health risk to dental personnel from this contamination is unknown. The authors assessed used amalgamators from the federal service inventory for the amounts of mercury vapor levels, as well as the visual presence of mercury contamination. They evaluated these amalgamators for potential mercury vapor health risk, using established National Institute for Occupational Safety and Health methods and American Conference of Governmental Industrial Hygienists standards. Ten of the 11 amalgamators assessed had measurable mercury vapor levels. Four amalgamators were found to have internal static mercury vapor levels above Occupational Safety and Health Administration ceiling limit thresholds. During a simulated worst-case clinical use protocol, the authors found that no amalgamators produced mercury vapor in the breathing space of dental personnel that exceeded established time-weighted federal mercury vapor limits. Amalgamators may be contaminated internally with metallic mercury. Although the authors detected mercury vapor from these units during aggressive, simulated clinical use, dilution factors combined with room air exchange were found to keep health risks below established federal safety thresholds. Dental personnel should be aware that amalgamators may be contaminated with mercury and produce minute amounts of mercury vapor. These contaminated amalgamators may require disposal as environmentally hazardous waste.

  2. Water ingestion during swimming activities in a pool: a pilot study.

    PubMed

    Dufour, Alfred P; Evans, Otis; Behymer, Thomas D; Cantú, Ricardo

    2006-12-01

    Chloroisocyanurates are commonly added to outdoor swimming pools to stabilize chlorine disinfectants. The chloroisocyanurates decompose slowly to release chlorine and cyanuric acid. Studies conducted to determine if the chloroisocyanurates might be toxic to swimmers showed that they were not and that ingested cyanuric acid passed through the body unmetabolized. This fact was used to determine the amount of water swallowed during swimming activity. Fifty-three recreational swimmers, using a community swimming pool disinfected with cyanuric acid stabilized chlorine, participated in the study. The participants did not swim on the day before or after the test swim. The swimmers were asked to actively swim for at least 45 minutes and to collect their urine for the next 24 hours. Cyanuric acid was measured in pool water using high performance liquid chromatography and porous graphitic carbon columns with UV detection. The urine sample assay required a clean-up procedure to remove urinary proteins and interfering substances. Results of the study indicate that non-adults ingest about twice as much water as adults during swimming activity. The average amount of water swallowed by non-adults and adults was 37 ml and 16 ml, respectively. The design for this study and the analytical methodology used to assay cyanuric acid in swimming pool water and human urine were effective for measuring the volume of water swallowed during swimming activity.

  3. Evaluation of BAM (butorphanol-azaperone-medetomidine) in captive African lion (Panthera leo) immobilization.

    PubMed

    Semjonov, Aleksandr; Andrianov, Vladimir; Raath, Jacobus P; Orro, Toomas; Venter, Derik; Laubscher, Liesel; Pfitzer, Silke

    2017-07-01

    The combination of butorphanol, azaperone and medetomidine (BAM) with subsequent antagonism by naltrexone-yohimbine or naltrexone-atipamezole was evaluated for reversible immobilization of captive African lions (Panthea leo). Prospective, clinical trial. Twenty lions, 11 males and nine females, weighing 38-284 kg were immobilized in South Africa. The BAM volume dose rate administered was 0.005-0.008 mL kg -1 (0.6 mL 100 kg -1 ). Physiologic variables were recorded every 5 minutes. Four arterial blood samples were collected from all animals at 20, 30, 40 and 50 minutes after immobilization for analysis of blood-gases and acid-base status. The actual doses administered were as follows: butorphanol, 0.18±0.03 mg kg -1 ; azaperone, 0.07±0.01 mg kg -1 ; and medetomidine, 0.07±0.01 mg kg -1 . The inductions were calm and smooth, and induction time ranged from 4 to 10 minutes (7±2 minutes). The amount of time needed to work with each lion was 70 minutes, and no additional drug doses were needed. Heart rate (40±8 beats minute -1 ) and respiratory frequency (15±4 breaths minute -1 ) were stable throughout immobilization. The mean arterial blood pressure of all animals was stable but elevated (142±16 mmHg). The rectal temperature slightly increased over time but remained within acceptable range. The recovery time was significantly shorter when using naltrexone and atipamezole (9±1 minutes) compared to using naltrexone and yohimbine (22±7 minutes). The BAM combination proved to be reliable for general veterinary anaesthesia in lions. During anaesthesia, minor veterinary procedures such a blood collection, intubation, vaccination and collaring could safely be performed with no additional dosing required. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  4. Factors Influencing Amount of Weekly Exercise Time in Colorectal Cancer Survivors.

    PubMed

    Chou, Yun-Jen; Lai, Yeur-Hur; Lin, Been-Ren; Liang, Jin-Tung; Shun, Shiow-Ching

    Performing regular exercise of at least 150 minutes weekly has benefits for colorectal cancer survivors. However, barriers inhibit these survivors from performing regular exercise. The aim of this study was to explore exercise behaviors and significant factors influencing weekly exercise time of more than 150 minutes in colorectal cancer survivors. A cross-sectional study design was used to recruit participants in Taiwan. Guided by the ecological model of health behavior, exercise barriers were assessed including intrapersonal, interpersonal, and environment-related barriers. A multiple logistic regression was used to explore the factors associated with the amount of weekly exercise. Among 321 survivors, 57.0% of them had weekly exercise times of more than 150 minutes. The results identified multiple levels of significant factors related to weekly exercise times including intrapersonal factors (occupational status, functional status, pain, interest in exercise, and beliefs about the importance of exercise) and exercise barriers related to environmental factors (lack of time and bad weather). No interpersonal factors were found to be significant. Colorectal cancer survivors experienced low levels of physical and psychological distress. Multiple levels of significant factors related to exercise time including intrapersonal factors as well as exercise barriers related to environmental factors should be considered. Healthcare providers should discuss with their patients how to perform exercise programs; the discussion should address multiple levels of the ecological model such as any pain problems, functional status, employment status, and time limitations, as well as community environment.

  5. Development of Recombinase Polymerase Amplification Assays for Detection of Orientia tsutsugamushi or Rickettsia typhi.

    PubMed

    Chao, Chien-Chung; Belinskaya, Tatyana; Zhang, Zhiwen; Ching, Wei-Mei

    2015-01-01

    Sensitive, specific and rapid diagnostic tests for the detection of Orientia tsutsugamushi (O. tsutsugamushi) and Rickettsia typhi (R. typhi), the causative agents of scrub typhus and murine typhus, respectively, are necessary to accurately and promptly diagnose patients and ensure that they receive proper treatment. Recombinase polymerase amplification (RPA) assays using a lateral flow test (RPA-nfo) and real-time fluorescent detection (RPA-exo) were developed targeting the 47-kDa gene of O. tsutsugamushi or 17 kDa gene of R. typhi. The RPA assay was capable of detecting O. tsutsugamushi or R. typhi at levels comparable to that of the quantitative PCR method. Both the RPA-nfo and RPA-exo methods performed similarly with regards to sensitivity when detecting the 17 kDa gene of R. typhi. On the contrary, RPA-exo performed better than RPA-nfo in detecting the 47 kDa gene of O. tsutsugamushi. The clinical performance of the O. tsutsugamushi RPA assay was evaluated using either human patient samples or infected mouse samples. Eight out of ten PCR confirmed positives were determined positive by RPA, and all PCR confirmed negative samples were negative by RPA. Similar results were obtained for R. typhi spiked patient sera. The assays were able to differentiate O. tsutsugamushi and R. typhi from other phylogenetically related bacteria as well as mouse and human DNA. Furthermore, the RPA-nfo reaction was completed in 20 minutes at 37°C followed by a 10 minute incubation at room temperature for development of an immunochromatographic strip. The RPA-exo reaction was completed in 20 minutes at 39°C. The implementation of a cross contamination proof cassette to detect the RPA-nfo fluorescent amplicons provided an alternative to regular lateral flow detection strips, which are more prone to cross contamination. The RPA assays provide a highly time-efficient, sensitive and specific alternative to other methods for diagnosing scrub typhus or murine typhus.

  6. Development of Recombinase Polymerase Amplification Assays for Detection of Orientia tsutsugamushi or Rickettsia typhi

    PubMed Central

    Chao, Chien-Chung; Belinskaya, Tatyana; Zhang, Zhiwen; Ching, Wei-Mei

    2015-01-01

    Sensitive, specific and rapid diagnostic tests for the detection of Orientia tsutsugamushi (O. tsutsugamushi) and Rickettsia typhi (R. typhi), the causative agents of scrub typhus and murine typhus, respectively, are necessary to accurately and promptly diagnose patients and ensure that they receive proper treatment. Recombinase polymerase amplification (RPA) assays using a lateral flow test (RPA-nfo) and real-time fluorescent detection (RPA-exo) were developed targeting the 47-kDa gene of O. tsutsugamushi or 17 kDa gene of R. typhi. The RPA assay was capable of detecting O. tsutsugamushi or R. typhi at levels comparable to that of the quantitative PCR method. Both the RPA-nfo and RPA-exo methods performed similarly with regards to sensitivity when detecting the 17 kDa gene of R. typhi. On the contrary, RPA-exo performed better than RPA-nfo in detecting the 47 kDa gene of O. tsutsugamushi. The clinical performance of the O. tsutsugamushi RPA assay was evaluated using either human patient samples or infected mouse samples. Eight out of ten PCR confirmed positives were determined positive by RPA, and all PCR confirmed negative samples were negative by RPA. Similar results were obtained for R. typhi spiked patient sera. The assays were able to differentiate O. tsutsugamushi and R. typhi from other phylogenetically related bacteria as well as mouse and human DNA. Furthermore, the RPA-nfo reaction was completed in 20 minutes at 37oC followed by a 10 minute incubation at room temperature for development of an immunochromatographic strip. The RPA-exo reaction was completed in 20 minutes at 39oC. The implementation of a cross contamination proof cassette to detect the RPA-nfo fluorescent amplicons provided an alternative to regular lateral flow detection strips, which are more prone to cross contamination. The RPA assays provide a highly time-efficient, sensitive and specific alternative to other methods for diagnosing scrub typhus or murine typhus. PMID:26161793

  7. Advancements in the Development of an Operational Lightning Jump Algorithm for GOES-R GLM

    NASA Technical Reports Server (NTRS)

    Shultz, Chris; Petersen, Walter; Carey, Lawrence

    2011-01-01

    Rapid increases in total lightning have been shown to precede the manifestation of severe weather at the surface. These rapid increases have been termed lightning jumps, and are the current focus of algorithm development for the GOES-R Geostationary Lightning Mapper (GLM). Recent lightning jump algorithm work has focused on evaluation of algorithms in three additional regions of the country, as well as, markedly increasing the number of thunderstorms in order to evaluate the each algorithm s performance on a larger population of storms. Lightning characteristics of just over 600 thunderstorms have been studied over the past four years. The 2 lightning jump algorithm continues to show the most promise for an operational lightning jump algorithm, with a probability of detection of 82%, a false alarm rate of 35%, a critical success index of 57%, and a Heidke Skill Score of 0.73 on the entire population of thunderstorms. Average lead time for the 2 algorithm on all severe weather is 21.15 minutes, with a standard deviation of +/- 14.68 minutes. Looking at tornadoes alone, the average lead time is 18.71 minutes, with a standard deviation of +/-14.88 minutes. Moreover, removing the 2 lightning jumps that occur after a jump has been detected, and before severe weather is detected at the ground, the 2 lightning jump algorithm s false alarm rate drops from 35% to 21%. Cold season, low topped, and tropical environments cause problems for the 2 lightning jump algorithm, due to their relative dearth in lightning as compared to a supercellular or summertime airmass thunderstorm environment.

  8. [Study on ultrafine vibration extraction technology of Rhizoma Chuanxiong].

    PubMed

    Dai, Long

    2009-04-01

    To explore the best ultrafine vibration extraction technology of Rhizoma Chuanxiong. Using the content of ligustrazine hydrochloride and ferulic acid as determination indexes, quadrature test was used to choose extraction times, time, solvent amount and to compare with the result of conventional extraction technology. The best condition of the Rhizoma chuanxiong was with 90% ethanol of 4 times volume, extracting 2 times in 25 degrees C, 15 minutes each time. Comparing with conventional extraction technology, extraction time of UVET was 1/6, solvent amount was 4/7, the extraction rate of marker components was 1.19 and 1.09 times, respectivley. UVET can improve the extracting rate of effective constituents, reduce the time and solvent amount and be used in industrialization.

  9. Microiontophoresis of kanamycin from micropipettes in vitro.

    PubMed

    Echeverria, E L; Gonzalez, L Q

    1986-01-01

    1. Currents ranging between 10 and 50 nA were passed during ten minutes through 0,02 M kanamycin (KM) filled micropipettes with tips submerged in 25 microliters of KCl 0,15 M. 2. The amount of KM released was measured by radioimmunoassay. 3. It was found that the amount of kanamycin released could be computed by the equation y = 0,16x + 0,59; where "x" stands for charge passed in micro Coulombs and "y" stands for the amount released in nanograms. 4. When Faraday's law was used to fit the experimental data, it was found that the electrodes behave in an acceptable linear fashion. The range of the transport number for KM was 0,089 to 0,142 for six electrodes.

  10. Development of real-time monitors for gaseous formaldehyde. Final report, 1 December 1988-30 September 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, T.J.; Barnes, R.H.

    1990-11-01

    Two new methods for real-time measurement of gaseous formaldehyde have been developed. One is a spectroscopic method based on direct fluorescence detection of gaseous formaldehyde following excitation with UV light. This method has been developed to the prototype stage by modifications of a commercial fluorescence SO2 detector to convert it to formaldehyde detection. The prototype spectroscopic formaldehyde monitor exhibits a detection limit of <30 ppbv, with a time response of about one minute. The second method is based on derivatization of formaldehyde in aqueous solution to form a fluorescent product. The detection of fluorescent product was made more sensitive bymore » using intense 254 nm light from a mercury lamp for excitation, thereby allowing use of a simple and efficient glass coil scrubber for collection of gaseous formaldehyde. The wet chemical formaldehyde monitor incorportating these improvements exhibits a detection limit for gaseous formaldehyde of 0.2 ppbv and for aqueous formaldehyde of 0.2 micromolar with time response of about one minute, following a lag time of 2 minutes. Both instruments were tested in the laboratory with gaseous formaldehyde standards, and the aqueous scrubbing/analysis method was field tested by continuous operation over a 10-day period in which outdoor and indoor air were sampled for alternate half-hour periods. A comparison of real-time (aqueous scrubbing/analysis) and integrated measurements, using dinitrophenylhydrazine (DNPH) impingers, showed close agreement between the real-time and DNPH data, even at concentrations as low as 1 ppbv.« less

  11. Statistical Analysis of the Polarimetric Cloud Analysis and Seeding Test (POLCAST) Field Projects

    NASA Astrophysics Data System (ADS)

    Ekness, Jamie Lynn

    The North Dakota farming industry brings in more than $4.1 billion annually in cash receipts. Unfortunately, agriculture sales vary significantly from year to year, which is due in large part to weather events such as hail storms and droughts. One method to mitigate drought is to use hygroscopic seeding to increase the precipitation efficiency of clouds. The North Dakota Atmospheric Research Board (NDARB) sponsored the Polarimetric Cloud Analysis and Seeding Test (POLCAST) research project to determine the effectiveness of hygroscopic seeding in North Dakota. The POLCAST field projects obtained airborne and radar observations, while conducting randomized cloud seeding. The Thunderstorm Identification Tracking and Nowcasting (TITAN) program is used to analyze radar data (33 usable cases) in determining differences in the duration of the storm, rain rate and total rain amount between seeded and non-seeded clouds. The single ratio of seeded to non-seeded cases is 1.56 (0.28 mm/0.18 mm) or 56% increase for the average hourly rainfall during the first 60 minutes after target selection. A seeding effect is indicated with the lifetime of the storms increasing by 41 % between seeded and non-seeded clouds for the first 60 minutes past seeding decision. A double ratio statistic, a comparison of radar derived rain amount of the last 40 minutes of a case (seed/non-seed), compared to the first 20 minutes (seed/non-seed), is used to account for the natural variability of the cloud system and gives a double ratio of 1.85. The Mann-Whitney test on the double ratio of seeded to non-seeded cases (33 cases) gives a significance (p-value) of 0.063. Bootstrapping analysis of the POLCAST set indicates that 50 cases would provide statistically significant results based on the Mann-Whitney test of the double ratio. All the statistical analysis conducted on the POLCAST data set show that hygroscopic seeding in North Dakota does increase precipitation. While an additional POLCAST field project would be necessary to obtain standardly accepted statistically significant results (p < 0.5) for the double ratio of precipitation amount, the obtained p-value of 0.063 is close and considering the positive result from other hygroscopic seeding experiments, the North Dakota Cloud Modification Project should consider implementation of hygroscopic seeding.

  12. Effect of increased exposure times on amount of residual monomer released from single-step self-etch adhesives.

    PubMed

    Altunsoy, Mustafa; Botsali, Murat Selim; Tosun, Gonca; Yasar, Ahmet

    2015-10-16

    The aim of this study was to evaluate the effect of increased exposure times on the amount of residual Bis-GMA, TEGDMA, HEMA and UDMA released from single-step self-etch adhesive systems. Two adhesive systems were used. The adhesives were applied to bovine dentin surface according to the manufacturer's instructions and were polymerized using an LED curing unit for 10, 20 and 40 seconds (n = 5). After polymerization, the specimens were stored in 75% ethanol-water solution (6 mL). Residual monomers (Bis-GMA, TEGDMA, UDMA and HEMA) that were eluted from the adhesives (after 10 minutes, 1 hour, 1 day, 7 days and 30 days) were analyzed by high-performance liquid chromatography (HPLC). The data were analyzed using 1-way analysis of variance and Tukey HSD tests. Among the time periods, the highest amount of released residual monomers from adhesives was observed in the 10th minute. There were statistically significant differences regarding released Bis-GMA, UDMA, HEMA and TEGDMA between the adhesive systems (p<0.05). There were no significant differences among the 10, 20 and 40 second polymerization times according to their effect on residual monomer release from adhesives (p>0.05). Increasing the polymerization time did not have an effect on residual monomer release from single-step self-etch adhesives.

  13. Design Control Systems of Human Machine Interface in the NTVS-2894 Seat Grinder Machine to Increase the Productivity

    NASA Astrophysics Data System (ADS)

    Ardi, S.; Ardyansyah, D.

    2018-02-01

    In the Manufacturing of automotive spare parts, increased sales of vehicles is resulted in increased demand for production of engine valve of the customer. To meet customer demand, we carry out improvement and overhaul of the NTVS-2894 seat grinder machine on a machining line. NTVS-2894 seat grinder machine has been decreased machine productivity, the amount of trouble, and the amount of downtime. To overcome these problems on overhaul the NTVS-2984 seat grinder machine include mechanical and programs, is to do the design and manufacture of HMI (Human Machine Interface) GP-4501T program. Because of the time prior to the overhaul, NTVS-2894 seat grinder machine does not have a backup HMI (Human Machine Interface) program. The goal of the design and manufacture in this program is to improve the achievement of production, and allows an operator to operate beside it easier to troubleshoot the NTVS-2894 seat grinder machine thereby reducing downtime on the NTVS-2894 seat grinder machine. The results after the design are HMI program successfully made it back, machine productivity increased by 34.8%, the amount of trouble, and downtime decreased 40% decrease from 3,160 minutes to 1,700 minutes. The implication of our design, it could facilitate the operator in operating machine and the technician easer to maintain and do the troubleshooting the machine problems.

  14. Rapid, Sensitive Detection of Botulinum Toxin on a Flexible Microfluidics Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warner, Marvin G.; Dockendorff, Brian P.; Feldhaus, Michael J.

    2004-10-30

    In this paper we will describe how high affinity reagents and a sensor configuration enabling rapid mass transport can be combined for rapid, sensitive biodetection. The system that we have developed includes a renewable surface immunoassay, which involves on-column detection of a fluorescently labeled secondary antibody in a sandwich immunoassay. Yeast display and directed molecular evolution were used to create high affinity antibodies to the botulinum toxin heavy chain receptor binding domain, AR1 and 3D12. A rotating rod renewable surface microcolumn was used to form a microliter-sized column containing beads functionalized with the capture antibody (AR1). The column was perfusedmore » with sample, wash solutions, and a fluorescently labeled secondary antibody (3D12) while the on-column fluorescence was monitored. Detection was accomplished in less than 5 minutes, with a total processing time of about 10 minutes. On-column detection of botulinum toxin was more sensitive and much faster than flow cytometry analysis on microbeads using the same reagents.« less

  15. A new microcomputer-based safety and life support system for solitary-living elderly people.

    PubMed

    Miyauchi, Kosuke; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Hahn, Allen W; Caldwell, W Morton

    2003-01-01

    A new safety and life support system has been developed to detect emergency situations of solitary-living elderly persons. The system employs a dual axis accelerometer, two low-power active filters, a low-power 8-bit single chip microcomputer and a personal handy phone. Body movements due to walking, running and posture changes are detected by the dual axis accelerometer and sent to the microcomputer. If the patient is in an inactive state for 5 minutes after falling, or for 64 minutes without previously falling, then the system automatically alarms the emergency situation, via the personal handy phone, to the patient's family, the fire station or the hospital.

  16. Determination of selected anions in water by ion chromatography

    USGS Publications Warehouse

    Fishman, Marvin J.; Pyen, Grace

    1979-01-01

    Ion chromatography is a rapid, sensitive, precise, and accurate method for the determination of major anions in rain water and surface waters. Simultaneous analyses of a single sample for bromide, chloride, fluoride, nitrate, nitrite, orthophosphate, and sulfate require approximately 20 minutes to obtain a chromatogram.Minimum detection limits range from 0.01 milligrams per liter for fluoride to 0.20 milligrams per liter for chloride and sulfate. Percent relative standard deviations were less than nine percent for all anions except nitrite in Standard Reference Water Samples. Only one reference sample contained nitrite and its concentration was near the minimum level of detection. Similar precision was found for chloride, nitrate, and sulfate at concentrations less than 5 milligrams per liter in rainfall samples. Precision for fluoride ranged from 12 to 22 percent, but is attributed to the low concentrations in these samples. The other anions were not detected.To determine accuracy of results, several samples were spiked with known concentrations of fluoride, chloride, nitrate, and sulfate; recoveries ranged from 96 to 103 percent. Known amounts of bromide and phosphate were added, separately, to several other waters, which contained bromide or phosphate. Recovery of added bromide and phosphate ranged from approximately 95 to 104 percent. No recovery data were obtained for nitrite.Chloride, nitrate, nitrite, orthophosphate, and sulfate, in several samples, were also determined independently by automated colorimetric procedures. An automated ion-selective electrode method was used to determine fluoride. Results are in agreement with results obtained by ion chromatography.

  17. Real-time trace ambient ammonia monitor for haze prevention

    NASA Astrophysics Data System (ADS)

    Nishimura, Katsumi; Sakaguchi, Yuhei; Crosson, Eric; Wahl, Edward; Rella, Chris

    2007-05-01

    In photolithography, haze prevention is of critical importance to integrated circuit chip manufacturers. Numerous studies have established that the presence of ammonia in the photolithography tool can cause haze to form on optical surfaces resulting in permanent damage to costly deep ultra-violet optics. Ammonia is emitted into wafer fab air by various semiconductor processes including coating steps in the track and CMP. The workers in the clean room also emit a significant amount of ammonia. Chemical filters are typically used to remove airborne contamination from critical locations but their lifetime and coverage cannot offer complete protection. Therefore, constant or periodic monitoring of airborne ammonia at parts-per-trillion (ppt) levels is critical to insure the integrity of the lithography process. Real time monitoring can insure that an accidental ammonia release in the clean room is detected before any optics is damaged. We have developed a transportable, highly accurate, highly specific, real-time trace gas monitor that detects ammonia using Cavity Ring-Down Spectroscopy (CRDS). The trace gas monitor requires no calibration gas standards, and can measure ammonia with 200 ppt sensitivity in five minutes with little or no baseline drift. In addition, the high spectral resolution of CRDS makes the analyzer less susceptible to interference from other gases when compared to other detection methods. In this paper we describe the monitor, focus on its performance, discuss the results of a careful comparison with ion chromatography (IC), and present field data measured inside the aligner and the reticule stocker at a semiconductor fab.

  18. Detection of irradiated fruits by gas-chromatographic methods.

    PubMed

    el-Dien, S; Farag, A

    1996-06-01

    To detect those fruits which have been subjected to low-dose irradiation (0.5-3 kGy), two methods of chromatography (GC-MS and LC-LC-GC-FID) were used to determine the radiolytic compounds of lipids formed after irradiation, such as alkanes and alkenes. Extraction of volatile hydrocarbon compounds from some parts of irradiated fruits, e.g. the flesh (avocado), seeds (papaya) and kernels (mango and apricot) was carried out. The analysis of hydrocarbons by GC-MS proved the suitability of using C17:1, C16:2, C15:0 and C14:1 as markers for avocados irradiated with a low dose (0.75 kGy). The same indicators appeared following the analysis of papayas and mangoes irradiated with 1.5, and 3.0 kGy. Also, C15:0, C14:1 and C16:3 can be used to identify apricots irradiated with a low dose (0.5 kGy). The detection of alkenes was only improved by a more selective isolation, e.g. of dienes or trienes by LC-LC-GC-FID. Within a few minutes, apricots and avocados irradiated at low doses (0.5 and 0.75 kGy) can be recognized by the indicators C16:2, C17:2 and C16:3, without interfering peaks. In all cases, C16:1, C16:2, C16:3 as well as significant amounts of C17:2 can be used as markers for fruit irradiation.

  19. Do Overweight Girls Overreport Physical Activity?

    PubMed Central

    McMurray, Robert G.; Ward, Dianne S.; Elder, John P.; Lytle, Leslie A.; Strikmiller, Patricia K.; Baggett, Christopher D.; Young, Deborah R.

    2008-01-01

    Objective To determine if overweight adolescent girls are more likely to overreport physical activity compared to normal-weight girls. Methods Participation in physical activities and perceived intensity of activities were assessed from the previous day physical activity recall (PDPAR) in 1021 girls aged 11-14 years old (37% overweight). Daily minutes of moderate to vigorous physical activity (MVPA) were measured using accelerometery. Results Girls in the “at-risk for overweight” and “overweight” categories had 17.7% and 19.4% fewer minutes of MVPA per block reported on the PDPAR compared to normal-weight girls (P<0.05). Conclusions Overweight adolescent girls tend to overreport their total amount of physical activity. PMID:18241138

  20. Drowsiness detection using heart rate variability.

    PubMed

    Vicente, José; Laguna, Pablo; Bartra, Ariadna; Bailón, Raquel

    2016-06-01

    It is estimated that 10-30 % of road fatalities are related to drowsy driving. Driver's drowsiness detection based on biological and vehicle signals is being studied in preventive car safety. Autonomous nervous system activity, which can be measured noninvasively from the heart rate variability (HRV) signal obtained from surface electrocardiogram, presents alterations during stress, extreme fatigue and drowsiness episodes. We hypothesized that these alterations manifest on HRV and thus could be used to detect driver's drowsiness. We analyzed three driving databases in which drivers presented different sleep-deprivation levels, and in which each driving minute was annotated as drowsy or awake. We developed two different drowsiness detectors based on HRV. While the drowsiness episodes detector assessed each minute of driving as "awake" or "drowsy" with seven HRV derived features (positive predictive value 0.96, sensitivity 0.59, specificity 0.98 on 3475 min of driving), the sleep-deprivation detector discerned if a driver was suitable for driving or not, at driving onset, as function of his sleep-deprivation state. Sleep-deprivation state was estimated from the first three minutes of driving using only one HRV feature (positive predictive value 0.80, sensitivity 0.62, specificity 0.88 on 30 drivers). Incorporating drowsiness assessment based on HRV signal may add significant improvements to existing car safety systems.

  1. Effect of Low Cu Amounts and Pre-Deformation on the Precipitation in Al-Mg-Si Alloys

    NASA Astrophysics Data System (ADS)

    Saito, Takeshi; Muraishi, Shinji; Marioara, Calin D.; Holmestad, Randi

    Transmission electron microscopy (TEM) studies were performed on two Al-Mg-Si alloys with low Cu additions (0.01 and 0.10 wt%) in order to investigate the effect of Cu and 10% pre-deformation on precipitate microstructure and its connection to mechanical properties. After 300 minutes aging at 190°C, fine microstructures associated with high hardness were observed in the alloy with 0.10% Cu. Pre-deformation led to heterogeneous distributions of precipitates along dislocations, causing microstructure coarsening. This effect was less pronounced in the alloy with the higher Cu amount.

  2. Estimating Rain Rates from Tipping-Bucket Rain Gauge Measurements

    NASA Technical Reports Server (NTRS)

    Wang, Jianxin; Fisher, Brad L.; Wolff, David B.

    2007-01-01

    This paper describes the cubic spline based operational system for the generation of the TRMM one-minute rain rate product 2A-56 from Tipping Bucket (TB) gauge measurements. Methodological issues associated with applying the cubic spline to the TB gauge rain rate estimation are closely examined. A simulated TB gauge from a Joss-Waldvogel (JW) disdrometer is employed to evaluate effects of time scales and rain event definitions on errors of the rain rate estimation. The comparison between rain rates measured from the JW disdrometer and those estimated from the simulated TB gauge shows good overall agreement; however, the TB gauge suffers sampling problems, resulting in errors in the rain rate estimation. These errors are very sensitive to the time scale of rain rates. One-minute rain rates suffer substantial errors, especially at low rain rates. When one minute rain rates are averaged to 4-7 minute or longer time scales, the errors dramatically reduce. The rain event duration is very sensitive to the event definition but the event rain total is rather insensitive, provided that the events with less than 1 millimeter rain totals are excluded. Estimated lower rain rates are sensitive to the event definition whereas the higher rates are not. The median relative absolute errors are about 22% and 32% for 1-minute TB rain rates higher and lower than 3 mm per hour, respectively. These errors decrease to 5% and 14% when TB rain rates are used at 7-minute scale. The radar reflectivity-rainrate (Ze-R) distributions drawn from large amount of 7-minute TB rain rates and radar reflectivity data are mostly insensitive to the event definition.

  3. Effect of Time Interval Between Tumescent Local Anesthesia Infiltration and Start of Surgery on Operative Field Visibility in Hand Surgery Without Tourniquet.

    PubMed

    Bashir, Muhammad Mustehsan; Qayyum, Rehan; Saleem, Muhammad Hammad; Siddique, Kashif; Khan, Farid Ahmad

    2015-08-01

    To determine the optimal time interval between tumescent local anesthesia infiltration and the start of hand surgery without a tourniquet for improved operative field visibility. Patients aged 16 to 60 years who needed contracture release and tendon repair in the hand were enrolled from the outpatient clinic. Patients were randomized to 10-, 15-, or 25-minute intervals between tumescent anesthetic solution infiltration (0.18% lidocaine and 1:221,000 epinephrine) and the start of surgery. The end point of tumescence anesthetic infiltration was pale and firm skin. The surgical team was blinded to the time of anesthetic infiltration. At the completion of the procedure, the surgeon and the first assistant rated the operative field visibility as excellent, fair, or poor. We used logistic regression models without and with adjustment for confounding variables. Of the 75 patients enrolled in the study, 59 (79%) were males, 7 were randomized to 10-minute time intervals (further randomization was stopped after interim analysis found consistently poor operative field visibility), and 34 were randomized to the each of the 15- and 25-minute groups. Patients who were randomized to the 25-minute delay group had 29 times higher odds of having an excellent operative visual field than those randomized to the 15-minute delay group. After adjusting for age, sex, amount of tumescent solution infiltration, and duration of operation, the odds ratio remained highly significant. We found that an interval of 25 minutes provides vastly superior operative field visibility; 10-minute delay had the poorest results. Therapeutic I. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Actual Time Required for Dynamic Fluoroscopic Intraoperative Cholangiography

    PubMed Central

    Whitwam, Paul; Turner, David; Kennedy, Kathy; Hashmi, Syed

    2005-01-01

    Objectives: This study was undertaken to determine the actual amount of time a dynamic fluoroscopic intraoperative cholangiogram adds to a laparoscopic cholecystectomy. A secondary objective was to define the information gained from this procedure. Methods: A consecutive case study of 52 patients undergoing laparoscopic cholecystectomy was used. Time was recorded from placement of a laparoscopic hemoclip across the cystic duct at its junction with the gallbladder until successful completion of the intraoperative cholangiogram. The mean, median, and range of times for these cases, as well as the results and false-negative rates, were determined. Results: Cholangiography was successfully completed in 96% of patients. The mean time added to laparoscopic cholecystectomy by the addition of dynamic fluoroscopic intraoperative cholangiography was 4.3 minutes. The median time was 3.0 minutes. The times ranged from 2.0 minutes to 16.0 minutes. Choledocholithiasis was present in 15.4% of these patients. The false-positive rate was zero in this study. Conclusions: Dynamic fluoroscopic intraoperative cholangiogram was fast and efficient. The information gained was significant in that 15% of patients proceeded on to laparoscopic common bile duct exploration. We conclude that intraoperative cholangiography should be a routine addition to laparoscopic cholecystectomy. PMID:15984705

  5. Response to gravity by Zea mays seedlings. I. Time course of the response

    NASA Technical Reports Server (NTRS)

    Bandurski, R. S.; Schulze, A.; Dayanandan, P.; Kaufman, P. B.

    1984-01-01

    Gravistimulation induces an asymmetric distribution of free indole-3-acetic acid (IAA) in the cortex-epidermis of the Zea mays L. cv 'Stowells Evergreen' mesocotyl within 15 minutes, the shortest time tested. IAA was measured by an isotope dilution method as the pentaflurobenzyl ester. The per cent IAA in the lower half of the mescotyl cortex was 56 to 57% at 15, 30, and 90 minutes after stimulus initiation. Curvature is detectable in the mescotyl within 3 minutes after beginning gravitropic stimulation. The rate of curvature of the mesocotyl increases during the first 60 minutes to maximum of about 30 degrees per hour. Thus, the growth asymmetry continues to increase for 45 minutes after hormone asymmetry is established. Free IAA occurs predominantly in the stele of the mesocotyl whereas esterified IAA is mainly in the mesocotyl cortex-epidermis. This compartmentation may permit determining in which tissue the hormone asymmetry arises. Current data suggest the asymmetry originated in the stele.

  6. Observation of gamma ray bursts and flares by the EGRET telescope on the Compton Gamma Ray Observatory

    NASA Technical Reports Server (NTRS)

    Schneid, E. J.; Bertsch, D. L.; Fichtel, C. E.; Hartman, R. C.; Hunter, S. D.; Kwok, P. W.; Mattox, J. R.; Sreekumar, P.; Thompson, D. J.; Kanbach, G.

    1992-01-01

    The Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory has observed energetic gamma ray bursts and flares. On May 3, 1991, EGRET detected a gamma ray burst both in the energy measuring NaI (Tl) scintillator and independently in the spark chamber imaging assembly. The NaI spectra were accumulated by a special BURST mode of EGRET. The spectra were measured over a range from 1 to 200 MeV, in three sequential spectra of 1,2, and 4 seconds. During the peak of the burst, six individual gamma rays were detected in the spark chamber, allowing a determination of the burst arrival direction. The intense flares of June were also detected. A solar flare on June 4 was observed to last for several minutes and for a brief time, less than a minute, had significant emission of gamma rays exceeding 150 MeV.

  7. RESPONSE OF GRANULATION TO SMALL-SCALE BRIGHT FEATURES IN THE QUIET SUN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andic, A.; Chae, J.; Goode, P. R.

    2011-04-10

    We detected 2.8 bright points (BPs) per Mm{sup 2} in the quiet Sun with the New Solar Telescope at Big Bear Solar Observatory, using the TiO 705.68 nm spectral line at an angular resolution {approx}0.''1 to obtain a 30 minute data sequence. Some BPs formed knots that were stable in time and influenced the properties of the granulation pattern around them. The observed granulation pattern within {approx}3'' of knots presents smaller granules than those observed in a normal granulation pattern, i.e., around the knots a suppressed convection is detected. Observed BPs covered {approx}5% of the solar surface and were notmore » homogeneously distributed. BPs had an average size of 0.''22, they were detectable for 4.28 minutes on average, and had an averaged contrast of 0.1% in the deep red TiO spectral line.« less

  8. Site of Allergic Airway Narrowing and the Influence of Exogenous Surfactant in the Brown Norway Rat

    PubMed Central

    Risse, Paul-André; Bullimore, Sharon R.; Benedetti, Andrea; Martin, James G.

    2012-01-01

    Background The parameters RN (Newtonian resistance), G (tissue damping), and H (tissue elastance) of the constant phase model of respiratory mechanics provide information concerning the site of altered mechanical properties of the lung. The aims of this study were to compare the site of allergic airway narrowing implied from respiratory mechanics to a direct assessment by morphometry and to evaluate the effects of exogenous surfactant administration on the site and magnitude of airway narrowing. Methods We induced airway narrowing by ovalbumin sensitization and challenge and we tested the effects of a natural surfactant lacking surfactant proteins A and D (Infasurf®) on airway responses. Sensitized, mechanically ventilated Brown Norway rats underwent an aerosol challenge with 5% ovalbumin or vehicle. Other animals received nebulized surfactant prior to challenge. Three or 20 minutes after ovalbumin challenge, airway luminal areas were assessed on snap-frozen lungs by morphometry. Results At 3 minutes, RN and G detected large airway narrowing whereas at 20 minutes G and H detected small airway narrowing. Surfactant inhibited RN at the peak of the early allergic response and ovalbumin-induced increase in bronchoalveolar lavage fluid cysteinyl leukotrienes and amphiregulin but not IgE-induced mast cell activation in vitro. Conclusion Allergen challenge triggers the rapid onset of large airway narrowing, detected by RN and G, and subsequent peripheral airway narrowing detected by G and H. Surfactant inhibits airway narrowing and reduces mast cell-derived mediators. PMID:22276110

  9. 21 CFR 522.775 - Doxapram.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... No. 000010 in § 510.600(c) of this chapter. (c) Conditions of use—(1) Amount. For intravenous use in dogs and cats at a dose of 21/2 to 5 mg per pound (/lb) body weight in barbiturate anesthesia, 0.5 mg... repeated in 15 to 20 minutes if necessary. (2) Indications for use. Administer to dogs, cats, and horses to...

  10. 21 CFR 522.775 - Doxapram.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... No. 000010 in § 510.600(c) of this chapter. (c) Conditions of use—(1) Amount. For intravenous use in dogs and cats at a dose of 21/2 to 5 mg per pound (/lb) body weight in barbiturate anesthesia, 0.5 mg... repeated in 15 to 20 minutes if necessary. (2) Indications for use. Administer to dogs, cats, and horses to...

  11. 21 CFR 522.775 - Doxapram.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Nos. 000010 and 015914 in § 510.600(c) of this chapter. (c) Conditions of use—(1) Amount. For intravenous use in dogs and cats at a dose of 21/2 to 5 mg per pound (/lb) body weight in barbiturate... be repeated in 15 to 20 minutes if necessary. (2) Indications for use. Administer to dogs, cats, and...

  12. Implementing Ten-Minute Tickers in Secondary Physical Education Classes

    ERIC Educational Resources Information Center

    Lynott, Francis J., III; Hushman, Glenn; Dixon, Jonette; McCarthy, Andrea

    2013-01-01

    In the late 1980s and early 1990s, the time spent in moderate-to-vigorous physical activity (MVPA) during physical education class time started to be measured and questioned (Bar-Or, 1987; Lacey & LaMaster, 1990; McGing, 1989; Simons-Morton, Taylor, Snider, & Huang, 1993). Researchers suggested that the amount of time students spent in…

  13. Occurrence of Exercise Dependence in a College-Aged Population

    ERIC Educational Resources Information Center

    Garman, J. F.; Hayduk, D.M.; Crider, D. A.; Hodel, M. M.

    2004-01-01

    Students (n = 257) were evaluated for scope and commitment to physical activity by use of self-reported data that assessed amount of activity per week and the obligatory or pathological nature of their activity patterns. Exhibiting atypical activity patterns, 21.8% of the students in the sample exercised 360 or more minutes per week and…

  14. Pretreatment of patients requiring oral contrast abdominal computed tomography with antiemetics: a randomized controlled trial of efficacy.

    PubMed

    Garra, Gregory; Singer, Adam J; Bamber, Danny; Chohan, Jasmine; Troxell, Regina; Thode, Henry C

    2009-04-01

    Ingestion of diatrizoate meglumine before abdominal computed tomography (CT) is time consuming. We hypothesized that pretreatment with metoclopramide or ondansetron would result in faster ingestion of diatrizoate meglumine than placebo. The study was a double-blind, randomized controlled trial on adults requiring oral contrast abdominal CT. Patients were randomized to placebo, metoclopramide 10 mg, or ondansetron 4 mg intravenously 15 minutes before ingesting 2 L of diatrizoate meglumine. The primary outcome was time to complete diatrizoate meglumine ingestion. Secondary outcome measures included volume of diatrizoate meglumine ingested, 100-mm visual analog scale for nausea at 15-minute intervals, time to CT, vomiting, and use of rescue antiemetics. The study was powered to detect a 60-minute difference in diatrizoate meglumine ingestion time between saline and medication groups. One hundred six patients were randomized; placebo (36), metoclopramide (35), and ondansetron (35). Groups were similar in baseline characteristics. Median (interquartile range) times for diatrizoate meglumine ingestion were placebo 109 minutes (82 to 135 minutes); metoclopramide 105 minutes (75 to 135 minutes); and ondansetron 110 minutes (79 to 140 minutes) (P=.67). Vomiting was less frequent with metoclopramide (3%) than placebo (18%) or ondansetron (9%) (P=.11). The visual analog scale for nausea at each point was not significantly different between groups (P=.11). The need for rescue antiemetics was lowest for metoclopramide (3%) compared with placebo (27%) and ondansetron (12%) (P=.02). Pretreatment with ondansetron or metoclopramide does not reduce oral contrast solution ingestion time.

  15. Effect of warm compress application on tissue temperature in healthy dogs.

    PubMed

    Millard, Ralph P; Towle-Millard, Heather A; Rankin, David C; Roush, James K

    2013-03-01

    To measure the effect of warm compress application on tissue temperature in healthy dogs. 10 healthy mixed-breed dogs. Dogs were sedated with hydromorphone (0.1 mg/kg, IV) and diazepam (0.25 mg/kg, IV). Three 24-gauge thermocouple needles were inserted to a depth of 0.5 cm (superficial), 1.0 cm (middle), and 1.5 cm (deep) into a shaved, lumbar, epaxial region to measure tissue temperature. Warm (47°C) compresses were applied with gravity dependence for periods of 5, 10, and 20 minutes. Tissue temperature was recorded before compress application and at intervals for up to 80 minutes after application. Control data were collected while dogs received identical sedation but with no warm compress. Mean temperature associated with 5 minutes of heat application at the superficial, middle, and deep depths was significantly increased, compared with the control temperature. Application for 10 minutes significantly increased the temperature at all depths, compared with 5 minutes of application. Mean temperature associated with 20 minutes of application was not different at the superficial or middle depths, compared with 10 minutes of application. Temperature at the deep depth associated with 10 minutes of application was significantly higher, compared with 20 minutes of application, but all temperature increases at this depth were minimal. Results suggested that application of a warm compress should be performed for 10 minutes. Changes in temperature at a tissue depth of 1.5 cm were minimal or not detected. The optimal compress temperature to achieve therapeutic benefits was not determined.

  16. The Accuracy of Eyelid Movement Parameters for Drowsiness Detection

    PubMed Central

    Wilkinson, Vanessa E.; Jackson, Melinda L.; Westlake, Justine; Stevens, Bronwyn; Barnes, Maree; Swann, Philip; Rajaratnam, Shantha M. W.; Howard, Mark E.

    2013-01-01

    Study Objectives: Drowsiness is a major risk factor for motor vehicle and occupational accidents. Real-time objective indicators of drowsiness could potentially identify drowsy individuals with the goal of intervening before an accident occurs. Several ocular measures are promising objective indicators of drowsiness; however, there is a lack of studies evaluating their accuracy for detecting behavioral impairment due to drowsiness in real time. Methods: In this study, eye movement parameters were measured during vigilance tasks following restricted sleep and in a rested state (n = 33 participants) at three testing points (n = 71 data points) to compare ocular measures to a gold standard measure of drowsiness (OSLER). The utility of these parameters for detecting drowsiness-related errors was evaluated using receiver operating characteristic curves (ROC) (adjusted by clustering for participant) and identification of optimal cutoff levels for identifying frequent drowsiness-related errors (4 missed signals in a minute using OSLER). Their accuracy was tested for detecting increasing frequencies of behavioral lapses on a different task (psychomotor vigilance task [PVT]). Results: Ocular variables which measured the average duration of eyelid closure (inter-event duration [IED]) and the ratio of the amplitude to velocity of eyelid closure were reliable indicators of frequent errors (area under the curve for ROC of 0.73 to 0.83, p < 0.05). IED produced a sensitivity and specificity of 71% and 88% for detecting ≥ 3 lapses (PVT) in a minute and 100% and 86% for ≥ 5 lapses. A composite measure of several eye movement characteristics (Johns Drowsiness Scale) provided sensitivities of 77% and 100% for detecting 3 and ≥ 5 lapses in a minute, with specificities of 85% and 83%, respectively. Conclusions: Ocular measures, particularly those measuring the average duration of episodes of eye closure are promising real-time indicators of drowsiness. Citation: Wilkinson VE; Jackson ML; Westlake J; Stevens B; Barnes M; Swann P; Rajaratnam SMW; Howard ME. The accuracy of eyelid movement parameters for drowsiness detection. J Clin Sleep Med 2013;9(12):1315-1324. PMID:24340294

  17. Research and Development Services: Methods Development. Appendices

    DTIC Science & Technology

    1982-07-23

    0.010-inch stainless-steel tubing. The order of the detectors is as follows: 1. Perkin-Elmer LC-75 variable-wavelength spectrometer with autocontrol . 2...reset it prior to the next injection. At 60 minutes, the micro- processor signals the Perkin-Elmer LC-75 with autocontrol to switch detection...variable-wavelength spectrometer with autocontrol set at 230 am for first 60 minutes of chromatogram then switched to 280 m. b. Altex Model 153 fixed

  18. Lateral flow immunoassay for the rapid detection of citrus tristeza virus

    USDA-ARS?s Scientific Manuscript database

    A lateral flow methodology was developed using gold nanoparticles for rapid detection of Citrus tristeza virus (CTV). The test strip was based on a sandwich immunoassay and could be accomplished within 10 minutes. A sample was considered negative for CTV when only the control line appeared; whereas,...

  19. ON ASYMMETRY OF MAGNETIC HELICITY IN EMERGING ACTIVE REGIONS: HIGH-RESOLUTION OBSERVATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian Lirong; Alexander, David; Zhu Chunming

    We employ the DAVE (differential affine velocity estimator) tracking technique on a time series of Michelson Doppler Imager (MDI)/1 minute high spatial resolution line-of-sight magnetograms to measure the photospheric flow velocity for three newly emerging bipolar active regions (ARs). We separately calculate the magnetic helicity injection rate of the leading and following polarities to confirm or refute the magnetic helicity asymmetry, found by Tian and Alexander using MDI/96 minute low spatial resolution magnetograms. Our results demonstrate that the magnetic helicity asymmetry is robust, being present in the three ARs studied, two of which have an observed balance of the magneticmore » flux. The magnetic helicity injection rate measured is found to depend little on the window size selected, but does depend on the time interval used between the two successive magnetograms being tracked. It is found that the measurement of the magnetic helicity injection rate performs well for a window size between 12 x 10 and 18 x 15 pixels and at a time interval {Delta}t = 10 minutes. Moreover, the short-lived magnetic structures, 10-60 minutes, are found to contribute 30%-50% of the magnetic helicity injection rate. Comparing with the results calculated by MDI/96 minute data, we find that the MDI/96 minute data, in general, can outline the main trend of the magnetic properties, but they significantly underestimate the magnetic flux in strong field regions and are not appropriate for quantitative tracking studies, so provide a poor estimate of the amount of magnetic helicity injected into the corona.« less

  20. Metabolism of acetylcholine in human erythrocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, E.S.

    1990-01-01

    In order to examine the possible role of erythrocyte acetylcholinesterase in the maintenance of membrane phospholipid content and membrane fluidity, experiments were performed to monitor the activity of the enzyme and follow the fate of one of its hydrolytic products, choline. Intact human erythrocytes were incubated with acetylcholine (choline methyl-{sup 14}C). The incubation resulted in the hydrolysis of acetylcholine to acetate and choline; the reaction was catalyzed by membrane acetylcholinesterase. The studies demonstrate the further metabolism of choline. Experiments were carried out to determine rate of hydrolysis of acetylcholine, uptake of choline, identification of intracellular metabolites of choline, and identificationmore » of radiolabeled membrane components. Erythrocytes at a 25% hematocrit were incubated in an isoosmotic bicarbonate buffer pH 7.4, containing glucose, adenosine, streptomycin and penicillin with 0.3 {mu}Ci of acetylcholine (choline methyl-{sup 14}C), for 24 hours. Aliquots of the erythrocyte suspension were taken throughout for analysis. Erythrocytes were washed free of excess substrate, lysed, and the hemolysate was extracted for choline and its metabolites. Blank samples containing incubation buffer and radiolabeled acetylcholine only, and erythrocyte hemolysate extracts were analyzed for choline content, the difference between blank samples and hemolysate extracts was the amount of choline originating from acetylcholine and attributable to acetylcholinesterase activity. The conversion of choline to {sup 14}C-betaine is noted after several minutes of incubation; at 30 minutes, more than 80% of {sup 14}C-choline is taken up and after several hours, detectable levels of radiolabeled S-adenosylmethionine were present in the hemolysate extract.« less

  1. A rapid field detection system for citrus huanglongbing associated ‘Candidatus Liberibacter asiaticus’ from the psyllid vector, diaphorina citri kuwayama and its implications in disease management

    USDA-ARS?s Scientific Manuscript database

    We report the development of an affordable detection kit for the detection of ‘Candidatus Liberibacter asiaticus’ (Las) from the psyllid vector, Diaphorina citri, which can provide real time test results in the field or field laboratory within 30-40 minutes without the need for expensive laboratory ...

  2. Spectroscopic Evolution of Disintegrating Planetesimals: Minute to Month Variability in the Circumstellar Gas Associated with WD 1145+017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redfield, Seth; Cauley, P. Wilson; Duvvuri, Girish M.

    With the recent discovery of transiting planetary material around WD 1145+017, a critical target has been identified that links the evolution of planetary systems with debris disks and their accretion onto the star. We present a series of observations, five epochs over a year, taken with Keck and the VLT, which for the first time show variability of circumstellar absorption in the gas disk surrounding WD 1145+017 on timescales of minutes to months. Circumstellar absorption is measured in more than 250 lines of 14 ions among 10 different elements associated with planetary composition, e.g., O, Mg, Ca, Ti, Cr, Mn,more » Fe, and Ni. Broad circumstellar gas absorption with a velocity spread of 225 km s{sup −1} is detected, but over the course of a year blueshifted absorption disappears, while redshifted absorption systematically increases. A correlation of equivalent width and oscillator strength indicates that the gas is not highly optically thick (median τ ≈ 2). We discuss simple models of an eccentric disk coupled with magnetospheric accretion to explain the basic observed characteristics of these high-resolution and high signal-to-noise observations. Variability is detected on timescales of minutes in the two most recent observations, showing a loss of redshifted absorption for tens of minutes, coincident with major transit events and consistent with gas hidden behind opaque transiting material. This system currently presents a unique opportunity to learn how the gas causing the spectroscopic, circumstellar absorption is associated with the ongoing accretion evidenced by photospheric contamination, as well as the transiting planetary material detected in photometric observations.« less

  3. Early Detection of Ureteropelvic Junction Obstruction Using Signal Analysis and Machine Learning: A Dynamic Solution to a Dynamic Problem.

    PubMed

    Blum, Emily S; Porras, Antonio R; Biggs, Elijah; Tabrizi, Pooneh R; Sussman, Rachael D; Sprague, Bruce M; Shalaby-Rana, Eglal; Majd, Massoud; Pohl, Hans G; Linguraru, Marius George

    2017-10-21

    We sought to define features that describe the dynamic information in diuresis renograms for the early detection of clinically significant hydronephrosis caused by ureteropelvic junction obstruction. We studied the diuresis renogram of 55 patients with a mean ± SD age of 75 ± 66 days who had congenital hydronephrosis at initial presentation. Five patients had bilaterally affected kidneys for a total of 60 diuresis renograms. Surgery was performed on 35 kidneys. We extracted 45 features based on curve shape and wavelet analysis from the drainage curves recorded after furosemide administration. The optimal features were selected as the combination that maximized the ROC AUC obtained from a linear support vector machine classifier trained to classify patients as with or without obstruction. Using these optimal features we performed leave 1 out cross validation to estimate the accuracy, sensitivity and specificity of our framework. Results were compared to those obtained using post-diuresis drainage half-time and the percent of clearance after 30 minutes. Our framework had 93% accuracy, including 91% sensitivity and 96% specificity, to predict surgical cases. This was a significant improvement over the same accuracy of 82%, including 71% sensitivity and 96% specificity obtained from half-time and 30-minute clearance using the optimal thresholds of 24.57 minutes and 55.77%, respectively. Our machine learning framework significantly improved the diagnostic accuracy of clinically significant hydronephrosis compared to half-time and 30-minute clearance. This aids in the clinical decision making process by offering a tool for earlier detection of severe cases and it has the potential to reduce the number of diuresis renograms required for diagnosis. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. The Effect of Acetone Amount Ratio as Co-Solvent to Methanol in Transesterification Reaction of Waste Cooking Oil

    NASA Astrophysics Data System (ADS)

    Julianto, T. S.; Nurlestari, R.

    2018-04-01

    The production of biodiesel from waste cooking oil by transesterification reaction using acetone as co-solvent has been carried out. This research studied the optimal amount ratio of acetone as co-solvent to methanol in the transesterification process using homogeneous alkaline catalyst KOH 1% (w/w) of waste cooking oil at room temperature for 15 minutes of reaction time. Mole ratio of waste cooking oil to methanol is 1:12. Acetone was added as co-solvent in varied amount ratio to methanol are 1:4, 1:2, and 1:1, respectively. The results of fatty acid methyl esters (FAME) were analysed using GC-MS instrument. The results showed that the optimal ratio is 1:4 with 99.93% of FAME yield.

  5. Objectively measured physical activity in Finnish employees: a cross-sectional study.

    PubMed

    Mutikainen, Sara; Helander, Elina; Pietilä, Julia; Korhonen, Ilkka; Kujala, Urho M

    2014-12-10

    To objectively measure the amount of intensity-specific physical activity by gender and age with respect to body mass index (BMI) during workdays and days off among Finnish employees. A cross-sectional study. Primary care occupational healthcare units. A sample of 9554 Finnish employees (4221 men and 5333 women; age range 18-65 years; BMI range 18.5-40 kg/m(2)) who participated in health assessments related to occupational health promotion. The amount of moderate-to-vigorous (MVPA) and vigorous (VPA) physical activity (≥3 and ≥6 metabolic equivalents, respectively) was assessed by estimating the minute-to-minute oxygen consumption from the recorded beat-to-beat R-R interval data. The estimation method used heart rate, respiration rate and on/off response information from R-R interval data calibrated by age, gender, height, weight and self-reported physical activity class. The proportion of participants fulfilling the aerobic physical activity recommendation of ≥150 min/week was calculated on the basis of ≥10 min bouts, by multiplying the VPA minutes by 2. Both MVPA and VPA were higher among men and during days off, and decreased with increasing age and BMI (p<0.001 for all). Similar results were observed when the probability of having a bout of MVPA or VPA lasting continuously for ≥10 min per measurement day was studied. The total amount of VPA was low among overweight (mean ≤2.6 min/day), obese (mean ≤0.6 min/day) and all women in the age group 51-65 years (mean ≤2.5 min/day) during both types of days. The proportion of participants fulfilling the aerobic physical activity recommendation was highest for normal weight men (65%; 95% CI 62% to 67%) and lowest for obese women (10%; 95% CI 8% to 12%). Objectively measured physical activity is higher among men and during days off, and decreases with increasing age and BMI. The amount of VPA is very low among obese, overweight and older women. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Rapid identification of Yersinia pestis and Brucella melitensis by chip-based continuous flow PCR

    NASA Astrophysics Data System (ADS)

    Dietzsch, Michael; Hlawatsch, Nadine; Melzer, Falk; Tomaso, Herbert; Gärtner, Claudia; Neubauer, Heinrich

    2012-06-01

    To combat the threat of biological agents like Yersinia pestis and Brucella melitensis in bioterroristic scenarios requires fast, easy-to-use and safe identification systems. In this study we describe a system for rapid amplification of specific genetic markers for the identification of Yersinia pestis and Brucella melitensis. Using chip based PCR and continuous flow technology we were able to amplify the targets simultaneously with a 2-step reaction profile within 20 minutes. The subsequent analysis of amplified fragments by standard gel electrophoresis requires another 45 minutes. We were able to detect both pathogens within 75 minutes being much faster than most other nucleic acid amplification technologies.

  7. Orbiting astronomical observatory-Copernicus. [scientific results

    NASA Technical Reports Server (NTRS)

    York, D. G.

    1973-01-01

    Of the three observatories planned in NASA's OAO program, one, OAO-3, is still in orbit and producing scientifically useful data. The prime experiment is the Princeton telescope spectrometer. Following a brief history of the OAO program, a description is given of the Princeton telescope with its 80-cm primary mirror, and of the spectrometer, which yields a resolution of up to 0.05 A. The spacecraft guidance system is also described. This system initially points the observatory to within a few arc minutes of the target, places the 0.3-arc sec slit on the star in less than 3 minutes, and holds on the star for up to 50 minutes with errors less than 0.05 arc sec. The main scientific results are described under the following categories: (1) the widespread presence of molecular hydrogen; (2) the search for other molecules, including detection of CO; (3) the nature of the interstellar medium as inferred from the detection of various atomic lines; (4) the study of chromospheres in late type stars; and (5) the study of mass loss in binaries and single stars.

  8. A multinational population survey of intravaginal ejaculation latency time.

    PubMed

    Waldinger, Marcel D; Quinn, Paul; Dilleen, Maria; Mundayat, Rajiv; Schweitzer, Dave H; Boolell, Mitradev

    2005-07-01

    Intravaginal ejaculation latency time (IELT), defined as the time between the start of vaginal intromission and the start of intravaginal ejaculation, is increasingly used in clinical trials to assess the amount of selective serotonin reuptake inhibitor-induced ejaculation delay in men with premature ejaculation. Prospectively, stopwatch assessment of IELTs has superior accuracy compared with retrospective questionnaire and spontaneous reported latency. However, the IELT distribution in the general male population has not been previously assessed. To determine the stopwatch assessed-IELT distribution in large random male cohorts of different countries. A total of 500 couples were recruited from five countries: the Netherlands, United Kingdom, Spain, Turkey, and the United States. Enrolled men were aged 18 years or older, had a stable heterosexual relationship for at least 6 months, with regular sexual intercourse. The surveyed population were not included or excluded by their ejaculatory status and comorbidities. This survey was performed on a "normal" general population. Sexual events and stopwatch-timed IELTs during a 4-week period were recorded, as well as circumcision status and condom use. The IELT, circumcision status, and condom use. The distribution of the IELT in all the five countries was positively skewed, with a median IELT of 5.4 minutes (range, 0.55-44.1 minutes). The median IELT decreased significantly with age, from 6.5 minutes in the 18-30 years group, to 4.3 minutes in the group older than 51 years (P<0.0001). The median IELT varied between countries, with the median value for Turkey being the lowest, i.e., 3.7 minutes (0.9-30.4 minutes), which was significantly different from each of the other countries. Comparison of circumcised (N=98) and not-circumcised (N=261) men in countries excluding Turkey resulted in median IELT values of 6.7 minutes (0.7-44.1 minutes) in circumcised compared with 6.0 minutes (0.5-37.4 minutes) in not-circumcised men (not significant). The median IELT value was not affected by condom use. The IELT distribution is positively skewed. The overall median value was 5.4 minutes but with differences between countries. For all five countries, median IELT values were independent of condom usage. In countries excluding Turkey, the median IELT values were independent of circumcision status.

  9. Adverse reactions to foods.

    PubMed

    Ring, J; Brockow, K; Behrendt, H

    2001-05-25

    Allergic reactions to foods represent a prominent, actual and increasing problem in clinical medicine. Symptoms of food allergy comprise skin reactions (urticaria, angioedema, eczema) respiratory (bronchoconstriction, rhinitis), gastrointestinal (cramping, diarrhea) and cardiovascular symptoms with the maximal manifestation of anaphylactic shock. They can be elicited by minute amounts of allergens. The diagnosis of food allergy is done by history, skin test, in vitro allergy diagnosis and--if necessary--oral provocation tests, if possible placebo-controlled. Avoidance of respective allergens for the allergic patient, however, is often complicated or impossible due to deficits in declaration regulations in many countries. Increasing numbers of cases including fatalities, due to inadvertent intake of food allergens are reported. It is therefore necessary to improve declaration laws and develop methods for allergen detection in foods. Allergens can be detected by serological methods (enzyme immunoassays, in vitro basophil histamine release or in vivo skin test procedures in sensitized individuals). The problem of diagnosis of food allergy is further complicated by cross-reactivity between allergens in foods and aeroallergens (pollen, animal epithelia, latex etc.). Elicitors of pseudo-allergic reactions with similar clinical symptomatology comprise low-molecular-mass chemicals (preservatives, colorings, flavor substances etc.). For some of them (e.g. sulfites) detection assays are available. In some patients classic allergic contact eczema can be elicited systemically after oral intake of low-molecular-mass contact allergens such as nickel sulfate or flavorings such as vanillin in foods. The role of xenobiotic components in foods (e.g. pesticides) is not known at the moment. In order to improve the situation of the food allergic patient, research programs to elucidate the pathophysiology and improve allergen detection strategies have to be implemented together with reinforced declaration regulations on a quantitative basis.

  10. Direct Detection of C_2H_2 in Air and Human Breath by Cw-Crds

    NASA Astrophysics Data System (ADS)

    Schmidt, Florian M.; Vaittinen, Olavi; Metsälä, Markus; Halonen, Lauri

    2010-06-01

    Continuous wave cavity ring-down spectroscopy (cw-CRDS) is an established cavity-enhanced absorption technique that can provide the necessary sensitivity, selectivity and fast acquisition time for many applications involving the detection of trace species. We present a simple but highly sensitive cw-CRDS spectrometer based on an external cavity diode laser operating in the near-infrared region. This instrument allows us to directly detect acetylene (C_2H_2) mixing ratios in air with a detection limit of 120 parts per trillion by volume (pptv) measuring on a C_2H_2 absorption line at 6565.620 cm-1. Acetylene is a combustion product that is routinely used in environmental monitoring as a marker for anthropogenic emissions. In a recent work, the spectrometer was employed to measure the level of acetylene in indoor and outdoor air in Helsinki. Continuous flow measurements with high time resolution (one minute) revealed strong fluctuations in the acetylene mixing ratio in outdoor air during daytime. Due to its non-invasive nature and fast response time, the analysis of exhaled breath for medical diagnostics is an excellent and straightforward alternative to methods using urine or blood samples. In an ongoing study, the cw-CRDS instrument is used to establish the baseline level of acetylene in the breath of the healthy population. An elevated amount of acetylene in breath could indicate exposure to combustion exhausts or other volatile organic compound (VOC) rich sources. The latest results of this investigation will be presented. F. M. Schmidt, O. Vaittinen, M. Metsälä, P. Kraus and L. Halonen, submitted for publication in Appl. Phys. B.

  11. A new method of scoring radiographic change in rheumatoid arthritis.

    PubMed

    Rau, R; Wassenberg, S; Herborn, G; Stucki, G; Gebler, A

    1998-11-01

    To test the reliability and to define the minimal detectable change of a new radiographic scoring method in rheumatoid arthritis (RA). Following the recommendations of an expert panel a new radiographic scoring method was defined. It scores 38 joints [all proximal interphalangeal (PIP) and metacarpophalangeal joints, 4 sites in the wrists, IP of the great toes, and metatarsophalangeals 2 to 5], regarding only the amount of joint surface destruction on a 0 to 5 scale for each joint. Each grade represents 20% of joint surface destruction. The method was tested by 5 readers on a set of 7 serial radiographs of hands and forefeet of 20 patients with progressive and destructive RA. Analysis of variance was performed, as it provides the best information about the capability of a method to detect real change and to define its sensitivity according to the minimal detectable change. Analysis of variance proved a high probability that the readers found real change with a ratio of intrapatient to intrareader standard deviation of 2.6. It also confirmed that one reader could detect a change of 3.5% of the total score with a probability of 95% and that different readers agreed upon a change of 4.6%. Inexperienced readers performed with comparable results to experienced readers. The time required for the reading averaged less than 10 minutes for the scoring of one set. The new radiographic scoring method proved to be reliable, precise, and easy to learn, with reasonable cost. Compared to published data, it may provide better results than the widely used Larsen score. These features favor our new method for use in clinical trials and in longterm observational studies in RA.

  12. Raman Analysis of Dilute Aqueous Samples by Localized Evaporation of Submicroliter Droplets on the Tips of Superhydrophobic Copper Wires.

    PubMed

    Cheung, Melody; Lee, Wendy W Y; McCracken, John N; Larmour, Iain A; Brennan, Steven; Bell, Steven E J

    2016-04-19

    Raman analysis of dilute aqueous solutions is normally prevented by their low signal levels. A very general method to increase the concentration to detectable levels is to evaporate droplets of the sample to dryness, creating solid deposits which are then Raman probed. Here, superhydrophobic (SHP) wires with hydrophilic tips have been used as supports for drying droplets, which have the advantage that the residue is automatically deposited at the tip. The SHP wires were readily prepared in minutes using electroless galvanic deposition of Ag onto copper wires followed by modification with a polyfluorothiol (3,3,4,4,5,5,6,6,7,7,8,8,9,9,10,10,10-heptadecafluoro-1-decanethiol, HDFT). Cutting the coated wires with a scalpel revealed hydrophilic tips which could support droplets whose maximum size was determined by the wire diameter. Typically, 230 μm wires were used to support 0.6 μL droplets. Evaporation of dilute melamine droplets gave solid deposits which could be observed by scanning electron microscopy (SEM) and Raman spectroscopy. The limit of detection for melamine using a two stage evaporation procedure was 1 × 10(-6) mol dm(-3). The physical appearance of dried droplets of sucrose and glucose showed that the samples retained significant amounts of water, even under high vacuum. Nonetheless, the Raman detection limits of sucrose and glucose were 5 × 10(-4) and 2.5 × 10(-3) mol dm(-3), respectively, which is similar to the sensitivity reported for surface-enhanced Raman spectroscopy (SERS) detection of glucose. It was also possible to quantify the two sugars in mixtures at concentrations which were similar to those found in human blood through multivariate analysis.

  13. A visual dual-aptamer logic gate for sensitive discrimination of prion diseases-associated isoform with reusable magnetic microparticles and fluorescence quantum dots.

    PubMed

    Xiao, Sai Jin; Hu, Ping Ping; Chen, Li Qiang; Zhen, Shu Jun; Peng, Li; Li, Yuan Fang; Huang, Cheng Zhi

    2013-01-01

    Molecular logic gates, which have attracted increasing research interest and are crucial for the development of molecular-scale computers, simplify the results of measurements and detections, leaving the diagnosis of disease either "yes" or "no". Prion diseases are a group of fatal neurodegenerative disorders that happen in human and animals. The main problem with a diagnosis of prion diseases is how to sensitively and selectively discriminate and detection of the minute amount of PrP(Res) in biological samples. Our previous work had demonstrated that dual-aptamer strategy could achieve highly sensitive and selective discrimination and detection of prion protein (cellular prion protein, PrP(C), and the diseases associated isoform, PrP(Res)) in serum and brain. Inspired by the advantages of molecular logic gate, we further conceived a new concept for dual-aptamer logic gate that responds to two chemical input signals (PrP(C) or PrP(Res) and Gdn-HCl) and generates a change in fluorescence intensity as the output signal. It was found that PrP(Res) performs the "OR" logic operation while PrP(C) performs "XOR" logic operation when they get through the gate consisted of aptamer modified reusable magnetic microparticles (MMPs-Apt1) and quantum dots (QDs-Apt2). The dual-aptamer logic gate simplifies the discrimination results of PrP(Res), leaving the detection of PrP(Res) either "yes" or "no". The development of OR logic gate based on dual-aptamer strategy and two chemical input signals (PrP(Res) and Gdn-HCl) is an important step toward the design of prion diseases diagnosis and therapy systems.

  14. Efficacy of methylene blue in an experimental model of calcium channel blocker-induced shock.

    PubMed

    Jang, David H; Donovan, Sean; Nelson, Lewis S; Bania, Theodore C; Hoffman, Robert S; Chu, Jason

    2015-04-01

    Calcium channel blocker poisonings account for a substantial number of reported deaths from cardiovascular drugs. Although supportive care is the mainstay of treatment, experimental therapies such as high-dose insulin-euglycemia and lipid emulsion have been studied in animal models and used in humans. In the most severe cases, even aggressive care is inadequate and deaths occur. In both experimental models and clinical cases of vasodilatory shock, methylene blue improves hemodynamic measures. It acts as a nitric oxide scavenger and inhibits guanylate cyclase that is responsible for the production of cyclic guanosine monophosphate (cGMP). Excessive cGMP production is associated with refractory vasodilatory shock in sepsis and anaphylaxis. The aim of this study is to determine the efficacy of methylene blue in an animal model of amlodipine-induced shock. Sprague-Dawley rats were anesthetized, ventilated, and instrumented for continuous blood pressure and pulse rate monitoring. The dose of amlodipine that produced death within 60 minutes was 17 mg/kg per hour (LD50). Rats were divided into 2 groups: amlodipine followed by methylene blue or amlodipine followed by normal saline solution, with 15 rats in each group. Rats received methylene blue at 2 mg/kg during 5 minutes or an equivalent amount of normal saline solution in 3 intervals from the start of the protocol: minutes 5, 30, and 60. The animals were observed for a total of 2 hours after the start of the protocol. Mortality risk and survival time were analyzed with Fisher's exact test and Kaplan-Meier survival analysis with the log rank test. Overall, 1 of 15 rats (7%) in the saline solution-treated group survived to 120 minutes compared with 5 of 15 (33%) in the methylene blue-treated group (difference -26%; 95% confidence interval [CI] -54% to 0.3%). The median survival time for the normal saline solution group was 42 minutes (95% CI 28.1 to 55.9 minutes); for the methylene blue group, 109 minutes (95% CI 93.9 to 124.1 minutes). Pulse rate and mean arterial pressure (MAP) differences between groups were analyzed until 60 minutes. Pulse rate was significantly higher in the methylene blue-treated group beginning 25 minutes after the start of the amlodipine infusion (95% CI 30 to 113 minutes) that was analyzed until 60 minutes. MAP was significantly higher in the methylene blue-treated group starting 25 minutes after the amlodipine infusion (95% CI 2 to 30 minutes) that was analyzed until 60 minutes. Methylene blue did not result in a significant difference in mortality risk. There was an increased pulse rate, MAP, and median survival time in the methylene blue group. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  15. Effect of Potassium on Uptake of 137Cs in Food Crops Grown on Coral Soils: Annual Crops at Bikini Atoll

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stone, E R; Robinson, W

    2002-02-01

    In 1954 a radioactive plume from the thermonuclear device code named BRAVO contaminated the principal residential islands, Eneu and Bikini, of Bikini Atoll (11{sup o} 36 minutes N; 165{sup o} 22 minutes E), now part of the Republic of the Marshall Islands. The resulting soil radioactivity diminished greatly over the three decades before the studies discussed below began. By that time the shorter-lived isotopes had all but disappeared, but strontium-90 ({sup 90}Sr), and cesium-137, ({sup 137}Cs) were reduced by only one half-life. Minute amounts of the long-lived isotopes, plutonium-239+240 ({sup 239+240}Pu) and americium-241 ({sup 241}Am), were present in soil, butmore » were found to be inconsequential in the food chain of humans and land animals. Rather, extensive studies demonstrated that the major concern for human health was {sup 137}Cs in the terrestrial food chain (Robison et al., 1983; Robison et al., 1997). The following papers document results from several studies between 1986 and 1997 aimed at minimizing the {sup 137}Cs content of annual food crops. The existing literature on radiocesium in soils and plant uptake is largely a consequence of two events: the worldwide fallout of 1952-58, and the fallout from Chernobyl. The resulting studies have, for the most part, dealt either with soils containing some amount of silicate clays and often with appreciable K, or with the short-term development of plants in nutrient cultures.« less

  16. A possible space-based tsunami early warning system using observations of the tsunami ionospheric hole.

    PubMed

    Kamogawa, Masashi; Orihara, Yoshiaki; Tsurudome, Chiaki; Tomida, Yuto; Kanaya, Tatsuya; Ikeda, Daiki; Gusman, Aditya Riadi; Kakinami, Yoshihiro; Liu, Jann-Yenq; Toyoda, Atsushi

    2016-12-01

    Ionospheric plasma disturbances after a large tsunami can be detected by measurement of the total electron content (TEC) between a Global Positioning System (GPS) satellite and its ground-based receivers. TEC depression lasting for a few minutes to tens of minutes termed as tsunami ionospheric hole (TIH) is formed above the tsunami source area. Here we describe the quantitative relationship between initial tsunami height and the TEC depression rate caused by a TIH from seven tsunamigenic earthquakes in Japan and Chile. We found that the percentage of TEC depression and initial tsunami height are correlated and the largest TEC depressions appear 10 to 20 minutes after the main shocks. Our findings imply that Ionospheric TEC measurement using the existing ground receiver networks could be used in an early warning system for near-field tsunamis that take more than 20 minutes to arrive in coastal areas.

  17. A possible space-based tsunami early warning system using observations of the tsunami ionospheric hole

    PubMed Central

    Kamogawa, Masashi; Orihara, Yoshiaki; Tsurudome, Chiaki; Tomida, Yuto; Kanaya, Tatsuya; Ikeda, Daiki; Gusman, Aditya Riadi; Kakinami, Yoshihiro; Liu, Jann-Yenq; Toyoda, Atsushi

    2016-01-01

    Ionospheric plasma disturbances after a large tsunami can be detected by measurement of the total electron content (TEC) between a Global Positioning System (GPS) satellite and its ground-based receivers. TEC depression lasting for a few minutes to tens of minutes termed as tsunami ionospheric hole (TIH) is formed above the tsunami source area. Here we describe the quantitative relationship between initial tsunami height and the TEC depression rate caused by a TIH from seven tsunamigenic earthquakes in Japan and Chile. We found that the percentage of TEC depression and initial tsunami height are correlated and the largest TEC depressions appear 10 to 20 minutes after the main shocks. Our findings imply that Ionospheric TEC measurement using the existing ground receiver networks could be used in an early warning system for near-field tsunamis that take more than 20 minutes to arrive in coastal areas. PMID:27905487

  18. Care Situation for Female Victims of Sexual Violence in Metropolitan Emergency Departments with Charité/Berlin as an Example

    PubMed Central

    Hoffmann-Walbeck, H.; Möckel, M.; Etzold, S.; David, M.

    2016-01-01

    of the perpetrators were friends or relations; 17 % were (ex-)partners. The waiting time in the Charité emergency departments amounted to 58 minutes on average, the medical treatment time 55 minutes. About 80 % of the personnel evaluated the “stuprum kit” as being altogether good or very good. More than ⅓ considered the time and room conditions as being unsuitable or rather unsuitable for the situation. Two thirds expressed the desire for further training and supervision. Conclusion: The structured procedure by means of the “stuprum kit” has proved its value. A need for optimisation was seen especially for the examination facilities in the emergency departments. PMID:27904168

  19. Radiative signatures from impact of Comet Shoemaker-Levy-9 on Jupiter

    NASA Technical Reports Server (NTRS)

    Ahrens, Thomas J.; Takata, Toshiko; O'Keefe, John D.; Orton, Glenn S.

    1994-01-01

    The visible optical power emitted from the expansion plumes from 0.4 and 2 km diameter fragments of Shoemaker-Levy are expected to be, approximately 25% and comparable to, the visible solar flux reflected from Jupiter, respectively, for several minutes, and could be easily observed by sensors on the Galileo spacecraft. Earth-based observers can detect these plumes as these expand over the SW limb of Jupiter and come into earth view some minutes after impact!

  20. Enhanced Application of 18F-FDG PET/CT in Bladder Cancer by Adding Early Dynamic Acquisition to a Standard Delayed PET Protocol.

    PubMed

    Yoon, Hai-Jeon; Yoo, Jang; Kim, Yemi; Lee, Dong Hyeon; Kim, Bom Sahn

    2017-10-01

    We investigated the value of early dynamic (ED) PET for the detection and characterization of bladder cancer. Fifty-two bladder cancer patients were prospectively enrolled. The study protocol was composed of ED, whole-body (WB, 60 minutes after injection), and additional delayed (AD, 120 minutes after injection) PET acquisition. Early dynamic PET was acquired for 10 minutes and reconstructed as 5 frames at 2-minute intervals. A focal radiotracer accumulation confined to the bladder wall was considered as PET positive and referred for further quantitative measurement. SUVmax on ED (SUVmax, SUVmax, SUVmax, SUVmax, and SUVmax for 5 frames), WB (SUVmax), and AD PET (SUVmax) were measured. PET results were correlated with bladder cancer pathology variables. The sensitivities of ED, WB, and AD PET for bladder cancer were 84.6%, 57.7%, and 61.2%, respectively. The sensitivity of ED PET was significantly higher than that of WB (P = 0.002) and AD PET (P = 0.008). On ED PET, SUVmax was significantly correlated with muscle invasiveness, histological grade, and pathological tumor size (P = 0.018, P = 0.030, and P = 0.030). On WB and AD PET, only pathological tumor size showed significant positive correlation with SUVmax and SUVmax (P = 0.043 and P = 0.007). Early dynamic PET can help to detect and characterize bladder cancer.

  1. Evaluation of plasma diazepam and nordiazepam concentrations following administration of diazepam intravenously or via suppository per rectum in dogs.

    PubMed

    Probst, Curtis W; Thomas, William B; Moyers, Tamberlyn D; Martin, Tomas; Cox, Sherry

    2013-04-01

    To evaluate the pharmacokinetics of diazepam administered per rectum via compounded (ie, not commercially available) suppositories and determine whether a dose of 2 mg/kg in this formulation would result in plasma concentrations shown to be effective for control of status epilepticus or cluster seizures (ie, 150 to 300 ng/mL) in dogs within a clinically useful interval (10 to 15 minutes). 6 healthy mixed-breed dogs. Dogs were randomly assigned to 2 groups of 3 dogs each in a crossover-design study. Diazepam (2 mg/kg) was administered IV or via suppository per rectum, and blood samples were collected at predetermined time points. Following a 6- or 7-day washout period, each group received the alternate treatment. Plasma concentrations of diazepam and nordiazepam were analyzed via reversed phase high-performance liquid chromatography. Plasma concentrations of diazepam and nordiazepam exceeded the targeted range ≤ 3 minutes after IV administration in all dogs. After suppository administration, targeted concentrations of diazepam were not detected in any dogs, and targeted concentrations of nordiazepam were detected after 90 minutes (n = 2 dogs) or 120 minutes (3) or were not achieved (1). On the basis of these results, administration of 2 mg of diazepam/kg via the compounded suppositories used in the present study cannot be recommended for emergency treatment of seizures in dogs.

  2. BOKS 45906: a CV with an Orbital Period of 56.6 Min in the Kepler Field?

    NASA Technical Reports Server (NTRS)

    Ramsay, Gavin; Howell, Steve B.; Wood, Matt A.; Smale, Alan; Barclay, Thomas; Seebode, Sally A.; Gelino, Dawn; Still, Martin; Cannizzo, John K.

    2013-01-01

    BOKS 45906 was found to be a blue source in the Burrell-Optical-Kepler Survey which showed a 3 magnitude outburst lasting approximately 5 days. We present the Kepler light curve of this source which covers nearly 3 years. We find that it is in a faint optical state for approximately half the time and shows a series of outbursts separated by distinct dips in flux. Using data with 1 minute sampling, we find clear evidence that in its low state BOKS 45906 shows a flux variability on a period of 56.5574 plus or minus 0.0014 minutes and a semi-amplitude of approximately 3 percent. Since we can phase all the 1 minute cadence data on a common ephemeris using this period, it is probable that 56.56 minutes is the binary orbital period. Optical spectra of BOKS 45906 show the presence of Balmer lines in emission indicating it is not an AM CVn (pure Helium) binary. Swift data show that it is a weak X-ray source and is weakly detected in the bluest of the UVOT filters. We conclude that BOKS 45906 is a cataclysmic variable with a period shorter than the 'period-bounce' systems and therefore BOKS 45906 could be the first helium-rich cataclysmic variable detected in the Kepler field.

  3. 9 CFR 113.28 - Detection of mycoplasma contamination.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REQUIREMENTS Standard Procedures § 113.28 Detection of mycoplasma contamination. The heart infusion test, using heart infusion broth and heart infusion agar, provided in this section shall be conducted when a test... inactivated at 56 °C for 30 minutes. (b) Heart infusion broth shall be prepared as provided in this paragraph...

  4. Short duration flares in GALEX data

    NASA Astrophysics Data System (ADS)

    Brasseur, Clara; Osten, Rachel A.

    2018-06-01

    Flares on cool stars indicate short time-scale magnetic reconnection processes that provide temporary increases in the stellar radiative output. While recent work has focused on long-duration flares from solar-like stars and those of lower mass, the existence of short-duration flares in the ultraviolet has not been systematically probed before. We will present an interesting population of short duration flares we discovered in a sample of ~37,000 light curves observed from 2009-2012 by the GALEX and Kepler missions. These flares range in duration from under a minute to a few minutes and are almost entirely distinct from a previous flare survey of Kepler data. We were able to detect this unique population of flares because the time resolution of the GALEX data allowed us to construct light curves with a 10 second cadence and thus detect shorter duration flares than could be detected within Kepler data. We applied algorithmic flare detection to a sample of ~37,000 stars, and identified a final count of 2,065 flares on 1,121 stars. We discuss the implication of these events for the flare frequency distributions of solar-like stars.

  5. Flooding the Zone: A Ten-Point Approach to Assessing Critical Thinking as Part of the AACSB Accreditation Process

    ERIC Educational Resources Information Center

    Cavaliere, Frank; Mayer, Bradley W.

    2012-01-01

    Undergoing the accreditation process of the Association to Advance Collegiate Schools of Business (AACSB) can be quite daunting and stressful. It requires prodigious amounts of planning, record-keeping, and document preparation. It is not something that can be thrown together at the last minute. The same is true of the five-year reaccreditation…

  6. Pseudotargeted MS Method for the Sensitive Analysis of Protein Phosphorylation in Protein Complexes.

    PubMed

    Lyu, Jiawen; Wang, Yan; Mao, Jiawei; Yao, Yating; Wang, Shujuan; Zheng, Yong; Ye, Mingliang

    2018-05-15

    In this study, we presented an enrichment-free approach for the sensitive analysis of protein phosphorylation in minute amounts of samples, such as purified protein complexes. This method takes advantage of the high sensitivity of parallel reaction monitoring (PRM). Specifically, low confident phosphopeptides identified from the data-dependent acquisition (DDA) data set were used to build a pseudotargeted list for PRM analysis to allow the identification of additional phosphopeptides with high confidence. The development of this targeted approach is very easy as the same sample and the same LC-system were used for the discovery and the targeted analysis phases. No sample fractionation or enrichment was required for the discovery phase which allowed this method to analyze minute amount of sample. We applied this pseudotargeted MS method to quantitatively examine phosphopeptides in affinity purified endogenous Shc1 protein complexes at four temporal stages of EGF signaling and identified 82 phospho-sites. To our knowledge, this is the highest number of phospho-sites identified from the protein complexes. This pseudotargeted MS method is highly sensitive in the identification of low abundance phosphopeptides and could be a powerful tool to study phosphorylation-regulated assembly of protein complex.

  7. Trace-fiber color discrimination by electrospray ionization mass spectrometry: a tool for the analysis of dyes extracted from submillimeter nylon fibers.

    PubMed

    Tuinman, Albert A; Lewis, Linda A; Lewis, Samuel A

    2003-06-01

    The application of electrospray ionization mass spectrometry (ESI-MS) to trace-fiber color analysis is explored using acidic dyes commonly employed to color nylon-based fibers, as well as extracts from dyed nylon fibers. Qualitative information about constituent dyes and quantitative information about the relative amounts of those dyes present on a single fiber become readily available using this technique. Sample requirements for establishing the color identity of different samples (i.e., comparative trace-fiber analysis) are shown to be submillimeter. Absolute verification of dye mixture identity (beyond the comparison of molecular weights derived from ESI-MS) can be obtained by expanding the technique to include tandem mass spectrometry (ESI-MS/MS). For dyes of unknown origin, the ESI-MS/MS analyses may offer insights into the chemical structure of the compound-information not available from chromatographic techniques alone. This research demonstrates that ESI-MS is viable as a sensitive technique for distinguishing dye constituents extracted from a minute amount of trace-fiber evidence. A protocol is suggested to establish/refute the proposition that two fibers--one of which is available in minute quantity only--are of the same origin.

  8. Perfluorocarbon Tracer Experiments on a 2 km Scale in Manchester Showing Ingress of Pollutants into a Building

    NASA Astrophysics Data System (ADS)

    Matthews, James; Wright, Matthew; Bacak, Asan; Silva, Hugo; Priestley, Michael; Martin, Damien; Percival, Carl; Shallcross, Dudley

    2016-04-01

    Cyclic perfluorocarbons (PFCs) have been used to measure the passage of air in urban and rural settings as they are chemically inert, non-toxic and have low background concentrations. The use of pre-concentrators and chemical ionisation gas chromatography enables concentrations of a few parts per quadrillion (ppq) to be measured in bag samples. Three PFC tracers were used in Manchester, UK in the summer of 2015 to map airflow in the city and ingress into buildings: perfluomethylcyclohexane (PMCH), perfluoro-2-4-dimethylcyclohexane (mPDMCH) and perfluoro-2-methyl-3-ethylpentene (PMEP). A known quantity of each PFC was released for 15 minutes from steel canisters using pre-prepared PFC mixtures. Release points were chosen to be upwind of the central sampling location (Simon Building, University of Manchester) and varied in distance up to 2.2 km. Six releases using one or three tracers in different configurations and under different conditions were undertaken in the summer. Three further experiments were conducted in the Autumn, to more closely investigate the rate of ingress and decay of tracer indoors. In each experiment, 10 litre samples were made over 30 minutes into Tedlar bags, starting at the same time the as PFC release. Samples were taken in 11 locations chosen from 15 identified areas including three in public parks, three outside within the University of Manchester area, seven inside and five outside of the Simon building and two outside a building nearby. For building measurements, receptors were placed inside the buildings on different floors; outside measurements were achieved through a sample line out of the window. Three of the sample positions inside the Simon building were paired with samplers outside to allow indoor-outdoor comparisons. PFC concentrations varied depending on location and height. The highest measured concentrations occurred when the tracer was released at sunrise; up to 330 ppq above background (11 ppq) of PMCH was measured at the 6th floor of the Simon Building from a release 1.9 km away. One experiment sampled for an additional two 30 minute periods in four locations inside and one location outside the Simon Building in order to investigate how long it took for air to enter and leave the building. For this measurement, 1.3 g of PMCH was released 1.9 km away and average roof level wind speed was 7.8 m/s. The highest measurement of PMCH outside was 54 ppq above background, and 46 ppq inside. After the first 30 minutes, the PFC concentration returned to background levels outside, but other internal rooms still had elevated PFC concentrations between 10 and 16 ppq above background an hour after release demonstrating that pollutants may persist within buildings having passed outside. In the final experiment, the wind direction changed so the sampling locations were not directly downwind of the release point, but nevertheless a small amount of PFC tracer above background was detected at the highest sampling point on the 6th floor of the Simon Building (14 ppq above background), and a smaller amount at street level.

  9. A preliminary appraisal of the Garber-Wellington Aquifer, southern Logan and northern Oklahoma counties, Oklahoma

    USGS Publications Warehouse

    Carr, Jerry E.; Marcher, Melvin V.

    1977-01-01

    The Garber-Wellington aquifer, which dips westward at 30 to 40 feet per mile, consists of about 900 feet of interbedded sandstone, shale, and siltstone. Sandstone comprises 35 to 75 percent of the aquifer and averages about 50 percent. Water-table conditions generally exist in the upper 200 feet in the outcrop area of the aquifer; semi-artesian or artesian conditions exist below a depth of 200 feet and beneath rocks of the Hennessey Group (predominantly shale) where the aquifer is fully saturated. Water containing more than 1,000 milligrams per liter dissolved solids occurs at various depths through the area. The altitude of the base of fresh water ranges from 250 feet above sea level in the south-central part of the area to 950 feet in the northwestern part. The thickness of the fresh-water zone ranges from less than 150 feet in the northern part of the area to about 850 feet in the southern part. The total amount of water stored in the fresh-water zone is estimated to be 21 million acre-feet based on specific yield of 0.20. Minimum recharge to the aquifer in 1975 is estimated to be 190 acre-feet per square mile or about 10 percent of the annual precipitation. Total minimum recharge to the aquifer in the study area in 1975 is estimated to be 129,000 acre-feet. Streams in the area are the principal means of ground-water discharge; the amount of discharge is essentially the same as recharge. The amount of groundwater used for municipal and rural water supply in 1975 is estimated to have been 5,000 acre-feet; a similar amount may have been used for industrial purposes. As a result of pumping, the potentiometric surface in 1975 had been lowered about 200 feet in the vicinity of Edmond and about 100 feet in the vicinity of Nichols Hills. Chemical analyses of water from the aquifer indicates that hardness is greater in the upper part of the aquifer than in the lower part, and that sulfate, chloride, and dissolved solids increase with depth. Reported yields of wells more than 250 feet deep range from 70 to 475 gallons per minute and average 240 gallons per minute. Potential well yields range from 225 gallons per minute when the fresh-water zone is 350 feet thick to about 550 gallons per minute where the fresh water zone is 850 feet thick. These estimates of potential yield are based on an available drawdown of half the thickness of the fresh-water zone and a specific capacity of 1.3 gallons per minute per foot. Intrusion of saline water into the fresh-water zone is a potential threat to water quality in the aquifer if the pressure head in the fresh-water zone is reduced sufficiently to allow upconing of saline water. One way to avoid the problem of upconing is by steady pumping at low rates from widely spaced wells; however, information required to determine pumping rates and well spacing is not available. For proper aquifer management the distribution of wells and rates of withdrawals should be designed to capture maximum recharge to the ground-water system. This may be accomplished by developing regional ground-water gradients that are sufficiently large to move water to pumpage centers but not so steep as to cause upconing of saline water or excessive water-level declines.

  10. A Crash Course in using Pulsars to Detect Gravitational Waves

    NASA Astrophysics Data System (ADS)

    Lommen, Andrea N.; NANOGrav

    2014-01-01

    A collection of well-timed millisecond pulsars makes a “pulsar timing array”, an “observatory” capable of detecting and characterizing small perturbations in spacetime called gravitational waves. In this 12-minute crash course you will learn how pulsars are timed, how you can use them to detect gravitational waves, who and what telescopes are engaged in this international enterprise, and how you can get involved.

  11. Predicting Epileptic Seizures in Advance

    PubMed Central

    Moghim, Negin; Corne, David W.

    2014-01-01

    Epilepsy is the second most common neurological disorder, affecting 0.6–0.8% of the world's population. In this neurological disorder, abnormal activity of the brain causes seizures, the nature of which tend to be sudden. Antiepileptic Drugs (AEDs) are used as long-term therapeutic solutions that control the condition. Of those treated with AEDs, 35% become resistant to medication. The unpredictable nature of seizures poses risks for the individual with epilepsy. It is clearly desirable to find more effective ways of preventing seizures for such patients. The automatic detection of oncoming seizures, before their actual onset, can facilitate timely intervention and hence minimize these risks. In addition, advance prediction of seizures can enrich our understanding of the epileptic brain. In this study, drawing on the body of work behind automatic seizure detection and prediction from digitised Invasive Electroencephalography (EEG) data, a prediction algorithm, ASPPR (Advance Seizure Prediction via Pre-ictal Relabeling), is described. ASPPR facilitates the learning of predictive models targeted at recognizing patterns in EEG activity that are in a specific time window in advance of a seizure. It then exploits advanced machine learning coupled with the design and selection of appropriate features from EEG signals. Results, from evaluating ASPPR independently on 21 different patients, suggest that seizures for many patients can be predicted up to 20 minutes in advance of their onset. Compared to benchmark performance represented by a mean S1-Score (harmonic mean of Sensitivity and Specificity) of 90.6% for predicting seizure onset between 0 and 5 minutes in advance, ASPPR achieves mean S1-Scores of: 96.30% for prediction between 1 and 6 minutes in advance, 96.13% for prediction between 8 and 13 minutes in advance, 94.5% for prediction between 14 and 19 minutes in advance, and 94.2% for prediction between 20 and 25 minutes in advance. PMID:24911316

  12. METHOD OF CHEMICAL DECONTAMINATION OF STAINLESS STEEL NUCLEAR FACILITIES

    DOEpatents

    Pancer, G.P.; Zegger, J.L.

    1961-12-19

    A chemical method is given for removing activated corrosion products on the primary system surfaces of a pressurized water reactor. The corrosion product deposits are composed chiefly of magnetite (Fe/sub 3/O/sub 4/) with small amounts of nickel and chromium oxides. The corroded surfaces are first flushed with a caustic permanganate primary solution consisting of sodium hydroxide and potassium permanganate followed by a secondary rinse solution of ammonium citrate and citric acid containing the complexing agent Versene in small amounts. Demineralized water is used to clean out the primary and secondary solutions and a 60-minute drying period precedes the rinse solution. (AEC)

  13. Diffuse optical monitoring of peripheral tissues during uncontrolled internal hemorrhage in a porcine model

    PubMed Central

    Vishwanath, Karthik; Gurjar, Rajan; Wolf, David; Riccardi, Suzannah; Duggan, Michael; King, David

    2018-01-01

    Reliable, continuous and noninvasive blood flow and hemoglobin monitoring in trauma patients remains a critical, but generally unachieved goal. Two optical sensing methods - diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS) – are used to monitor and detect internal hemorrhage. Specifically, we investigate if cutaneous perfusion measurements acquired using DCS and DRS in peripheral (thighs and ear-lobe) tissues could detect severe hemorrhagic shock in a porcine model. Four animals underwent high-grade hepato-portal injury in a closed abdomen, to induce uncontrolled hemorrhage and were subsequently allowed to bleed for 10 minutes before fluid resuscitation. DRS and DCS measurements of cutaneous blood flow were acquired using fiber optical probes placed on the thigh and earlobe of the animals and were obtained repeatedly starting from 1 to 5 minutes pre-injury, up to several minutes post shock. Clear changes were observed in measured optical spectra across all animals at both sites. DCS-derived cutaneous blood flow decreased sharply during hemorrhage, while DRS-derived vascular saturation and hemoglobin paralleled cardiac output. All derived optical parameters had the steepest changes during the rapid initial hemorrhage unambiguously. This suggests that a combined DCS and DRS based device might provide an easy-to-use, non-invasive, internal-hemorrhage detection system that can be used across a wide array of clinical settings. PMID:29552394

  14. Alarm characterization for a continuous glucose monitor that replaces traditional blood glucose monitoring.

    PubMed

    McGarraugh, Geoffrey

    2010-01-01

    Continuous glucose monitoring (CGM) devices available in the United States are approved for use as adjuncts to self-monitoring of blood glucose (SMBG); all CGM alarms require SMBG confirmation before treatment. In this report, an analysis method is proposed to determine the CGM threshold alarm accuracy required to eliminate SMBG confirmation. The proposed method builds on the Clinical and Laboratory Standards Institute (CLSI) guideline for evaluating CGM threshold alarms using data from an in-clinic study of subjects with type 1 diabetes. The CLSI method proposes a maximum time limit of +/-30 minutes for the detection of hypo- and hyperglycemic events but does not include limits for glucose measurement accuracy. The International Standards Organization (ISO) standard for SMBG glucose measurement accuracy (ISO 15197) is +/-15 mg/dl for glucose <75 mg/dl and +/-20% for glucose > or = 75 mg/dl. This standard was combined with the CLSI method to more completely characterize the accuracy of CGM alarms. Incorporating the ISO 15197 accuracy margins, FreeStyle Navigator CGM system alarms detected 70 mg/dl hypoglycemia within 30 minutes at a rate of 70.3%, with a false alarm rate of 11.4%. The device detected high glucose in the range of 140-300 mg/dl within 30 minutes at an average rate of 99.2%, with a false alarm rate of 2.1%. Self-monitoring of blood glucose confirmation is necessary for detecting and treating hypoglycemia with the FreeStyle Navigator CGM system, but at high glucose levels, SMBG confirmation adds little incremental value to CGM alarms. 2010 Diabetes Technology Society.

  15. FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

    NASA Technical Reports Server (NTRS)

    Bruno, John G.

    2013-01-01

    Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is called a "lights on" FRET response. The vitamin D aptamer beacon gives a "lights off" or inversely proportional fluorescence response to the amount of vitamin D present in diluted serum. These FRET-aptamer assays are rapid (<30 minutes), sensitive (low ng/mL detection limits), and quite easy to carry out (add sample, mix, and detect in the handheld reader). Benefits include the speed of the assays as well as the small amount of space taken up by the handheld reader and cuvette assays. The aptamer DNA sequences represent novel additional features of the existing (patent-pending) FRET-aptamer assay platform.

  16. Space communications scheduler: A rule-based approach to adaptive deadline scheduling

    NASA Technical Reports Server (NTRS)

    Straguzzi, Nicholas

    1990-01-01

    Job scheduling is a deceptively complex subfield of computer science. The highly combinatorial nature of the problem, which is NP-complete in nearly all cases, requires a scheduling program to intelligently transverse an immense search tree to create the best possible schedule in a minimal amount of time. In addition, the program must continually make adjustments to the initial schedule when faced with last-minute user requests, cancellations, unexpected device failures, quests, cancellations, unexpected device failures, etc. A good scheduler must be quick, flexible, and efficient, even at the expense of generating slightly less-than-optimal schedules. The Space Communication Scheduler (SCS) is an intelligent rule-based scheduling system. SCS is an adaptive deadline scheduler which allocates modular communications resources to meet an ordered set of user-specified job requests on board the NASA Space Station. SCS uses pattern matching techniques to detect potential conflicts through algorithmic and heuristic means. As a result, the system generates and maintains high density schedules without relying heavily on backtracking or blind search techniques. SCS is suitable for many common real-world applications.

  17. Measurements of glucose on the skin surface, in stratum corneum and in transcutaneous extracts: implications for physiological sampling.

    PubMed

    Cunningham, David D; Young, Douglas F

    2003-09-01

    Obtaining representative physiological samples for glucose analysis remains a challenge especially when developing less invasive glucose monitoring systems for diabetic patients. In the present study the glucose content of the stratum corneum was compared with the amount of glucose obtained by short aqueous extractions from a site on the dorsal wrist, using high pressure liquid chromatography with pulsed amperometric detection. Ten successive aqueous 1-minute extractions of the site yielded a total of 60 ng cm(-2). The total glucose content of the stratum corneum of the site, determined from 30 successive tape-strippings of the site, was 360 ng cm(-2). After tape-stripping, the transcutaneous aqueous extraction rate was 86 +/- 13 ng cm(-2) min(-1), compared with rates of 80-600 ng cm(-2) min(-1) obtained with suction effusion or microdialysis after tape-stripping. Glucose on the surface of the skin and within the stratum corneum should be considered as sources of extraneous glucose contamination during testing of less invasive glucose monitoring devices.

  18. Genotoxicity of corrosion eluates obtained from endosseous implants.

    PubMed

    Ribeiro, Daniel Araki; Matsumoto, Mariza Akemi; Padovan, Luís Eduardo Marques; Marques, Mariângela Esther Alencar; Salvadori, Daisy Maria Fávero

    2007-03-01

    Commercially pure titanium alloys are currently used as metallic biomaterials in implantology. Corrosion phenomena appear to play a decisive role in metallic implant long-term behavior. Thus, the goal of this study was to examine the genotoxic potential of corrosion eluates obtained from dental implants using Chinese ovary hamster cells in vitro by the single-cell gel (comet) assay. This technique detects deoxyribonucleic acid strand breaks in individual cells in alkaline conditions. The materials tested included 3 dental implants commercially available. Each of the tested materials was corroded in a solution consisting of equal amounts of acetic acid and sodium chloride (0.1 M) for 1, 3, 7, 14, and 21 days. The Chinese ovary hamster cultures were then exposed to all corrosion eluates obtained from endosseous dental implants for 30 minutes at 37 degrees C. None of the eluates was found to exhibit genotoxicity, regardless of the type of dental implant used. The results suggest that all dental implants tested in this study did not induce deoxyribonucleic acid breakage as depicted by the single-cell gel (comet) assay.

  19. Fully-automated in-syringe dispersive liquid-liquid microextraction for the determination of caffeine in coffee beverages.

    PubMed

    Frizzarin, Rejane M; Maya, Fernando; Estela, José M; Cerdà, Víctor

    2016-12-01

    A novel fully-automated magnetic stirring-assisted lab-in-syringe analytical procedure has been developed for the fast and efficient dispersive liquid-liquid microextraction (DLLME) of caffeine in coffee beverages. The procedure is based on the microextraction of caffeine with a minute amount of dichloromethane, isolating caffeine from the sample matrix with no further sample pretreatment. Selection of the relevant extraction parameters such as the dispersive solvent, proportion of aqueous/organic phase, pH and flow rates have been carefully evaluated. Caffeine quantification was linear from 2 to 75mgL(-1), with detection and quantification limits of 0.46mgL(-1) and 1.54mgL(-1), respectively. A coefficient of variation (n=8; 5mgL(-1)) of a 2.1% and a sampling rate of 16h(-1), were obtained. The procedure was satisfactorily applied to the determination of caffeine in brewed, instant and decaf coffee samples, being the results for the sample analysis validated using high-performance liquid chromatography. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Evaluating changes in brain vasculature of murine embryos in utero due to maternal alcohol consumption using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Raghunathan, Raksha; Wu, Chen; Singh, Manmohan; Liu, Chih-Hao; Miranda, Rajesh C.; Larin, Kirill V.

    2017-04-01

    Fetal Alcohol Syndrome (FAS) refers to the broad spectrum of developmental and behavioral effects caused due to prenatal alcohol exposure (PAE). Wide range of abnormalities vary depending on the amount of alcohol consumed and the period of consumption during gestation. PAE during early stages of pregnancy is very common. However a large number of women continue to consume alcohol even during the second trimester, a critical period for fetal neurogenesis and angiogenesis. Optical coherence tomography (OCT) has shown to be extremely useful in embryonic imaging. Our previous work showed that OCT is capable of quantitative assessment of ventriculomegaly caused by maternal alcohol consumption. Although structural changes and changes in blood flow in the fetal brain after maternal alcohol consumption have been studied, acute vasculature changes are not well documented. Speckle variance OCT (SVOCT), is a functional extension of OCT that has been used to study vasculature development in embryos. We use SVOCT, to detect vasculature changes in the embryonic brain in utero, minutes after maternal alcohol consumption.

  1. The effect of dilute baby shampoo on nasal mucociliary clearance in healthy subjects.

    PubMed

    Isaacs, Seth; Fakhri, Samer; Luong, Amber; Whited, Chad; Citardi, Martin J

    2011-01-01

    Biofilm formation has been implicated as an etiologic factor in the development of chronic rhinosinusitis (CRS). Nasal irrigation with surfactants including dilute baby shampoo have been proposed as an antibiofilm treatment for CRS patients. The effect of dilute baby shampoo on normal sinonasal mucosal function is unknown. Mucociliary clearance time (MCT), as measured by the time in minutes for a subject to detect a sweet taste after the application of a saccharin granules at the anterior part of the inferior turbinate, was performed before and shortly after nasal irrigation with 50 ml of 1% baby shampoo (Johnson & Johnson, New Brunswick, NJ) in 27 healthy volunteers. Mean MCTs before and after irrigation were 12.09 (±4.83 minutes) and 15.45 (±7.71 minutes) minutes, respectively. The mean difference, 3.37 minutes, was statistically significant (p = 0.031). Pre- and post-MCTs for each subject were not correlated (r = 0.324; p = 0.100). Nasal irrigations with dilute baby shampoo increase MCTs in healthy subjects. The impact of such interventions in CRS patients warrants additional investigation.

  2. Flow cytometric monitoring of bacterioplankton phenotypic diversity predicts high population-specific feeding rates by invasive dreissenid mussels.

    PubMed

    Props, Ruben; Schmidt, Marian L; Heyse, Jasmine; Vanderploeg, Henry A; Boon, Nico; Denef, Vincent J

    2018-02-01

    Species invasion is an important disturbance to ecosystems worldwide, yet knowledge about the impacts of invasive species on bacterial communities remains sparse. Using a novel approach, we simultaneously detected phenotypic and derived taxonomic change in a natural bacterioplankton community when subjected to feeding pressure by quagga mussels, a widespread aquatic invasive species. We detected a significant decrease in diversity within 1 h of feeding and a total diversity loss of 11.6 ± 4.1% after 3 h. This loss of microbial diversity was caused by the selective removal of high nucleic acid populations (29 ± 5% after 3 h). We were able to track the community diversity at high temporal resolution by calculating phenotypic diversity estimates from flow cytometry (FCM) data of minute amounts of sample. Through parallel FCM and 16S rRNA gene amplicon sequencing analysis of environments spanning a broad diversity range, we showed that the two approaches resulted in highly correlated diversity measures and captured the same seasonal and lake-specific patterns in community composition. Based on our results, we predict that selective feeding by invasive dreissenid mussels directly impacts the microbial component of the carbon cycle, as it may drive bacterioplankton communities toward less diverse and potentially less productive states. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.

  3. Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection

    PubMed Central

    Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan

    2011-01-01

    Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O2 content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. PMID:21497566

  4. Identification of a pheromone that increases anxiety in rats

    PubMed Central

    Inagaki, Hideaki; Kiyokawa, Yasushi; Tamogami, Shigeyuki; Watanabe, Hidenori; Takeuchi, Yukari; Mori, Yuji

    2014-01-01

    Chemical communication plays an important role in the social lives of various mammalian species. Some of these chemicals are called pheromones. Rats release a specific odor into the air when stressed. This stress-related odor increases the anxiety levels of other rats; therefore, it is possible that the anxiety-causing molecules are present in the stress-related odorants. Here, we have tried to identify the responsible molecules by using the acoustic startle reflex as a bioassay system to detect anxiogenic activity. After successive fractionation of the stress-related odor, we detected 4-methylpentanal and hexanal in the final fraction that still possessed anxiogenic properties. Using synthetic molecules, we found that minute amounts of the binary mixture, but not either molecule separately, increased anxiety in rats. Furthermore, we determined that the mixture increased a specific type of anxiety and evoked anxiety-related behavioral responses in an experimental model that was different from the acoustic startle reflex. Analyses of neural mechanisms proposed that the neural circuit related to anxiety was only activated when the two molecules were simultaneously perceived by two olfactory systems. We concluded that the mixture is a pheromone that increases anxiety in rats. To our knowledge, this is the first study identifying a rat pheromone. Our results could aid further research on rat pheromones, which would enhance our understanding of chemical communication in mammals. PMID:25512532

  5. Construction and production of oncotropic vectors, derived from MVM(p), that share reduced sequence homology with helper plasmids.

    PubMed

    Clément, Nathalie; Velu, Thierry; Brandenburger, Annick

    2002-09-01

    The production of currently available vectors derived from autonomous parvoviruses requires the expression of capsid proteins in trans, from helper sequences. Cotransfection of a helper plasmid always generates significant amounts of replication-competent virus (RCV) that can be reduced by the integration of helper sequences into a packaging cell line. Although stocks of minute virus of mice (MVM)-based vectors with no detectable RCV could be produced by transfection into packaging cells; the latter appear after one or two rounds of replication, precluding further amplification of the vector stock. Indeed, once RCVs become detectable, they are efficiently amplified and rapidly take over the culture. Theoretically RCV-free vector stocks could be produced if all homology between vector and helper DNA is eliminated, thus preventing homologous recombination. We constructed new vectors based on the structure of spontaneously occurring defective particles of MVM. Based on published observations related to the size of vectors and the sequence of the viral origin of replication, these vectors were modified by the insertion of foreign DNA sequences downstream of the transgene and by the introduction of a consensus NS-1 nick site near the origin of replication to optimize their production. In one of the vectors the inserted fragment of mouse genomic DNA had a synergistic effect with the modified origin of replication in increasing vector production.

  6. Updated O-C Diagrams for Several Bright HW Vir Binaries Observed with the Evryscope

    NASA Astrophysics Data System (ADS)

    Corcoran, Kyle A.; Barlow, Brad; Corbett, Hank; Fors, Octavi; Howard, Ward S.; Law, Nicholas; Ratzloff, Jeff

    2018-01-01

    HW Vir systems are eclipsing, post-common-envelope binaries consisting of a hot subdwarf star and a cooler M dwarf or brown dwarf companion. They show a strong reflection effect and have characteristically short orbital periods of only a few hours, allowing observers to detect multiple eclipses per night. Observed minus calculated (O-C) studies allow one to measure miniscule variations in the orbital periods of these systems by comparing observed eclipse timings to a calculated ephemeris. This technique is useful for detecting period changes due to secular evolution of the binary, gravitational wave emission, or reflex motion from an orbiting circumbinary object. Numerous eclipse timings obtained over several years are vital to the proper interpretation and analysis of O-C diagrams. The Evryscope – an array of twenty-four individual telescopes built by UNC and deployed on Cerro Tololo – images the entire Southern sky once every two minutes, producing an insurmountable amount of data for objects brighter than 16th magnitude. The cadence with which Evryscope exposes makes it an unparalleled tool for O-C analyses of HW Vir binaries; it will catalogue thousands of eclipses over the next several years. Here we present updated O-C diagrams for several HW Vir binaries using recent measurements from the Evryscope. We also use observations of AA Dor, an incredibly stable astrophysical clock, to characterize the accuracy of the Evryscope’s timestamps.

  7. Protein biomarker validation via proximity ligation assays.

    PubMed

    Blokzijl, A; Nong, R; Darmanis, S; Hertz, E; Landegren, U; Kamali-Moghaddam, M

    2014-05-01

    The ability to detect minute amounts of specific proteins or protein modifications in blood as biomarkers for a plethora of human pathological conditions holds great promise for future medicine. Despite a large number of plausible candidate protein biomarkers published annually, the translation to clinical use is impeded by factors such as the required size of the initial studies, and limitations of the technologies used. The proximity ligation assay (PLA) is a versatile molecular tool that has the potential to address some obstacles, both in validation of biomarkers previously discovered using other techniques, and for future routine clinical diagnostic needs. The enhanced specificity of PLA extends the opportunities for large-scale, high-performance analyses of proteins. Besides advantages in the form of minimal sample consumption and an extended dynamic range, the PLA technique allows flexible assay reconfiguration. The technology can be adapted for detecting protein complexes, proximity between proteins in extracellular vesicles or in circulating tumor cells, and to address multiple post-translational modifications in the same protein molecule. We discuss herein requirements for biomarker validation, and how PLA may play an increasing role in this regard. We describe some recent developments of the technology, including proximity extension assays, the use of recombinant affinity reagents suitable for use in proximity assays, and the potential for single cell proteomics. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge. © 2013.

  8. DNA-polyfluorophore Chemosensors for Environmental Remediation: Vapor-phase Identification of Petroleum Products in Contaminated Soil†

    PubMed Central

    Jiang, Wei; Wang, Shenliang; Yuen, Lik Hang; Kwon, Hyukin; Ono, Toshikazu

    2013-01-01

    Contamination of soil and groundwater by petroleum-based products is an extremely widespread and important environmental problem. Here we have tested a simple optical approach for detecting and identifying such industrial contaminants in soil samples, using a set of fluorescent DNA-based chemosensors in pattern-based sensing. We used a set of diverse industrial volatile chemicals to screen and identify a set of five short oligomeric DNA fluorophores on PEG-polystyrene microbeads that could differentiate the entire set after exposure to their vapors in air. We then tested this set of five fluorescent chemosensor compounds for their ability to respond with fluorescence changes when exposed to headgas over soil samples contaminated with one of ten different samples of crude oil, petroleum distillates, fuels, lubricants and additives. Statistical analysis of the quantitative fluorescence change data (as Δ(R,G,B) emission intensities) revealed that these five chemosensors on beads could differentiate all ten product mixtures at 1000 ppm in soil within 30 minutes. Tests of sensitivity with three of the contaminant mixtures showed that they could be detected and differentiated in amounts at least as low as one part per million in soil. The results establish that DNA-polyfluorophores may have practical utility in monitoring the extent and identity of environmental spills and leaks, while they occur and during their remediation. PMID:23878719

  9. Objective Quantification of Physical Activity in Bariatric Surgery Candidates and Normal-Weight Controls

    PubMed Central

    Bond, Dale S.; Jakicic, John M.; Vithiananthan, Sivamainthan; Thomas, J. Graham; Leahey, Tricia M.; Sax, Harry C.; Pohl, Dieter; Roye, G.D.; Ryder, Beth A.; Wing, Rena R.

    2009-01-01

    Background Physical activity (PA) is an important component of weight loss programs and may be encouraged for severely obese patients undergoing bariatric surgery. However, few studies have determined the amount and intensity of activities undertaken preoperatively by bariatric surgery patients using objective measures. Methods Using RT3 tri-axial accelerometers, this study compared 38 bariatric surgery candidates and 20 normal-weight controls on: 1) activity counts/hour; 2) minutes/day spent in moderate-to-vigorous intensity PA (MVPA) and vigorous intensity PA (VPA); and 3) level of compliance with national recommendations to accumulate 150 minutes/week of MVPA in bouts ≥ 10 minutes. Results Surgery candidates, compared to controls, recorded significantly (Ps < 0.01) fewer activity counts/hour (13799 ± 3758 vs 19462 ± 4259) and spent fewer minutes/day engaged in MVPA (26.4 ± 23.0 vs 52.4 ± 24.7) and VPA (1.2 ± 3.4 vs 11.8 ± 9.0). More than two-thirds (68%) of surgery candidates versus 13% of NW did not accumulate any MVPA in bouts ≥ 10 minutes and only 4.5% of Ob met the weekly MVPA recommendation compared to 40% of NW. Conclusion Bariatric surgery candidates have low PA levels and rarely engage in PA bouts of sufficient duration and intensity to maintain and improve health. Additional research is needed to determine how best to increase PA in bariatric surgery candidates. PMID:19837009

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nadel, G.L.; Malik, K.U.; Lew, D.B.

    The purpose of this study was to examine arachidonic acid (AA) metabolism and to characterize the type of adrenergic receptor (AR) involved in the production of the major metabolite of this fatty acid. ({sup 14}C)AA was incubated with GPT-rings and the radiolabelled products were extracted and separated by TLC method. The medium was also assayed for radiolabelled immunoreactive PG's (iPG's) and leukotrienes (LT) B4 and C4 by RIA or Enzyme immunoassay (EIA) after exposure to various AR agonists. ({sup 14}C)AA was incorporated into GPT-rings and metabolized mainly into iPGE2 and smaller amounts into PGF2{alpha}. Trace amounts of PGD2 and 6-keto-PGF1{alpha}more » but not LTB4 or LTC4 were detected by RIA and/or EIA. Incubation of GPT rings for 15 minutes with isoproterenol and salbutamol resulted in a significant increase of PGE2 synthesis (optimum conc: 10{sup {minus}7}, 10{sup {minus}7}M respectively). In contrast, dobutamine, norepinephrine, phenylnephrine and xylazine (up to 10{sup {minus}6}M) did not significantly increase PGE2 production. Isoproterenol-induced iPGE2 production was inhibited by a selective {beta}2 antagonist, butoxamine (70%: 10{sup {minus}7}M, 91%: 10{sup {minus}6}M) and somewhat reduced by {beta}1 antagonists practolol and metoprolol (30-64%:10{sup {minus}6}M). These data suggest that isoproterenol induced iPGE2 synthesis is primarily mediated via activation of {beta}2 adrenergic receptor.« less

  11. [Aconitine analogues in wild Aconitum plants: contents toxicity to mice and decrease by boiling].

    PubMed

    Kasahara, Yoshimasa; Itou, Takeshi; Numazawa, Toshiaki; Wada, Akinobu

    2013-01-01

    Simultaneous determination of four aconitine analogues (ACs) (AC; aconitine, HA; hypaconitine, JA; jesaconitine, MA; mesaconitine) in leaves and roots of wild Aconitum plants (Aconitum japonicum THUNBERG, Aconitum okuyamae Nakai) was carried out to elucidate the relation between toxicity to mice and ACs content determind by liquid chromatography tandem mass spectrometry. The total amounts of ACs in leaves, roots, petals and nectaries of Aconitum japonicum collected at Sagae-shi Tashiro were 5.9 μg/g, 928.1 μg/g, 46.1 μg/g, and 69.8 μg/g, respectively. Despite the high contents in nectary, commercial honey contained no ACs. Extract of wild Aconitum japonicum roots which contained ACs (2.69 mg/g) was administered to 5 mice orally at 1.0 g/kg (fresh root equivalent), and 2 mice died. On the other hand, 3 of 5 mice died after being given the standard AC (3.0 mg/kg, p.o.). These findings confirmed good coincidence between toxicity and quantitative values. Mice given extract of Aconitum okuyamae root (100 g/kg, p.o.) without ACs showed no toxic symptoms. Residual ACs in Aconitum leaves were examined after boiling. The remaining percentage of ACs in leaves after 0.5 minutes boiling was 31.6%, and the amount in the boiling water was 54.5%. MA is converted into benzoylmesaconine by hydrolysis (by boiling). Therefore food poisoning caused by Aconitum plants is explained by detection of benzoylmesaconine formed during food preparation.

  12. Monitoring Resource Utilization in a Health Care Coordination Program.

    PubMed

    Popejoy, Lori L; Jaddoo, Julie; Sherman, Jan; Howk, Christopher; Nguyen, Raymond; Parker, Jerry C

    2015-01-01

    This initial article describes the development of a health care coordination intervention and documentation system designed using the Agency for Healthcare Research and Quality (AHRQ) Care Coordination Atlas framework for Centers for Medicare & Medicaid-funded innovation project, Leveraging Information Technology to Guide High-Tech, High-Touch Care (LIGHT). The study occurred at an academic medical center that serves 114 counties. Twenty-five registered nurse care managers (NCMs) were hired to work with 137 providers in 10 family community and internal medicine clinics. Patients were allocated into one of the four tiers on the basis of their chronic medical conditions and health care utilization. Using a documentation system on the basis of the AHRQ domains developed for this study, time and touch data were calculated for 8,593 Medicare, Medicaid, or dual-eligible patients. We discovered through the touch and time analysis that the majority of health care coordination activity occurred in the AHRQ domains of communication, assess needs and goals, and facilitate transitions, accounting for 79% of the NCM time and 61% of the touches. As expected, increasing tier levels resulted in increased use of NCM resources. Tier 3 accounted for roughly 16% of the patients and received 159 minutes/member (33% of total minutes), and Tier 4 accounted for 4% of patients and received 316 minutes/member (17% of all minutes). In contrast Tier 2, which did not require routine touches per protocol, had 5,507 patients (64%), and those patients received 5,246 hours of health care coordination, or 57 minutes/member, and took 48% of NCM time. 1. The AHRQ Care Coordination Atlas offered a systematic way to build a documentation system that allowed for the extraction of data that was used to calculate the amount of time and the number of touches that NCMs delivered per member. 2. Using a framework to systematically guide the work of health care coordination helped NCMs to think strategically about the care being delivered, and has implications for improving coordination of care. 3. For the purpose of reimbursement and communication with payers about quality metrics, it is vital that the type of touches and amount of time spent in delivering care coordination be documented in a manner that can be easily retrieved to guide practice decisions.

  13. Measurements of the Acoustic Speaking Voice After Vocal Warm-up and Cooldown in Choir Singers.

    PubMed

    Onofre, Fernanda; Prado, Yuka de Almeida; Rojas, Gleidy Vannesa E; Garcia, Denny Marco; Aguiar-Ricz, Lílian

    2017-01-01

    The aim of this study was to evaluate the acoustic measurements of the vowel /a/ in modal recording before and after a singing voice resistance test and after 30 minutes of absolute rest in female choir singers. This is a prospective cohort study. A total of 13 soprano choir singers with experience in choir singing were evaluated through analysis of acoustic voice parameters at three points in time: before continuous use of the voice, after vocal warm-up and a singing test 60 minutes in duration respecting the pauses for breathing, and after vocal cooldown and an absolute voice rest for 30 minutes. The fundamental frequency increased after the voice resistance test (P = 0.012) and remained elevated after the 30 minutes of voice rest (P = 0.01). The jitter decreased after the voice resistance test (P = 0.02) and after the 30 minutes of voice rest. A significant difference was detected for the acoustic voice parameters relative average perturbation (RAP), (P = 0.05), and pitch perturbation quotient (PPQ), (P = 0.04), compared with the initial time point. The fundamental frequency increased after 60 minutes of singing and remained elevated after vocal cooldown and absolute rest for 30 minutes, proving an efficient parameter for identifying the changes inherent to voice demand during singing. Copyright © 2017. Published by Elsevier Inc.

  14. Quantitation of left ventricular ejection fraction reserve from early gated regadenoson stress Tc-99m high-efficiency SPECT.

    PubMed

    Brodov, Yafim; Fish, Mathews; Rubeaux, Mathieu; Otaki, Yuka; Gransar, Heidi; Lemley, Mark; Gerlach, Jim; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2016-12-01

    Ejection fraction (EF) reserve has been found to be a useful adjunct for identifying high risk coronary artery disease in cardiac positron emission tomography (PET). We aimed to evaluate EF reserve obtained from technetium-99m sestamibi (Tc-99m) high-efficiency (HE) SPECT. Fifty patients (mean age 69 years) undergoing regadenoson same-day rest (8-11 mCi)/stress (32-42 mCi) Tc-99m gated HE SPECT were enrolled. Stress imaging was started 1 minute after sequential intravenous regadenoson .4 mg and Tc-99m injections, and was composed of five 2 minutes supine gated acquisitions followed by two 4 minutes supine and upright images. Ischemic total perfusion deficit (ITPD) ≥5 % was considered as significant ischemia. Significantly lower mean EF reserve was obtained in the 5th and 9th minute after regadenoson bolus in patients with significant ischemia vs patients without (5th minute: -4.2 ± 4.6% vs 1.3 ± 6.6%, P = .006; 9th minute: -2.7 ± 4.8% vs 2.0 ± 6.6%, P = .03). Negative EF reserve obtained between 5th and 9th minutes of regadenoson stress demonstrated best concordance with significant ischemia and may be a promising tool for detection of transient ischemic functional changes with Tc-99m HE-SPECT.

  15. Clinical evaluation of the vector algorithm for neonatal hearing screening using automated auditory brainstem response.

    PubMed

    Keohane, Bernie M; Mason, Steve M; Baguley, David M

    2004-02-01

    A novel auditory brainstem response (ABR) detection and scoring algorithm, entitled the Vector algorithm is described. An independent clinical evaluation of the algorithm using 464 tests (120 non-stimulated and 344 stimulated tests) on 60 infants, with a mean age of approximately 6.5 weeks, estimated test sensitivity greater than 0.99 and test specificity at 0.87 for one test. Specificity was estimated to be greater than 0.95 for a two stage screen. Test times were of the order of 1.5 minutes per ear for detection of an ABR and 4.5 minutes per ear in the absence of a clear response. The Vector algorithm is commercially available for both automated screening and threshold estimation in hearing screening devices.

  16. Morphological study on permeating efficiency and localization of FCLA and HpD through membrane of lung cancer cell

    NASA Astrophysics Data System (ADS)

    Wu, Yunxia; Xing, Da; Tang, Yonghong

    2004-07-01

    It is reported that apoptosis of cancer cells in photodynamic therapy (PDT) is caused by 1O2 generated in photosensitization. In order to study the mechanism of this kind of 1O2-induced apoptosis, it is necessary to establish a special technique to dynamically detect intracellular production and localization of 1O2. FCLA, as a chemiluminescence probe to detect singlet oxygen (1O2) and superoxide (O2-.), has been used successfully in photodynamic and sonodynamic diagnosis in tissue level, recently. This paper reported a preliminary result of morphological study on permeating efficiency and localization of FCLA and hematoporphyrin derivative (HpD) through cellular membrane. Human lung cancer cell line (ASTC-a-1) was used in the experiment. The result of this research showed that both HpD and FCLA could permeate through cellular membrane and localize to prinuclear area, when HpD or FCLA was incubated with cells. Although the molecular weight of HpD is close to FCLA's, the permeating efficiency of HpD through membrane was different from that of FCLA. Intracellular FCLA concentration reached a peak after incubation for only 30 - 45 minutes, but amount of HpD in cells approached the equilibrium after incubation for near 22 h. In the experiment, we did not observe the evidence of FCLA or HpD penetrating into nucleolus. This study suggests that it is possibly to use a specific chemiluminescence probe to dynamcially detect the production and localization of 1O2 or 02-. in cell.

  17. Selective detection of Fe2+ by combination of CePO4:Tb3+ nanocrystal-H2O2 hybrid system with synchronous fluorescence scan technique.

    PubMed

    Chen, Hongqi; Ren, Jicun

    2012-04-21

    A new method for quenching kinetic discrimination of Fe(2+) and Fe(3+), and sensitive detection of trace amount of Fe(2+) was developed by using synchronous fluorescence scan technique. The principle of this assay is based on the quenching kinetic discrimination of Fe(2+) and Fe(3+) in CePO(4):Tb(3+) nanocrytals-H(2)O(2) hybrid system and the Fenton reaction between Fe(2+) and H(2)O(2). Stable, water-soluble and well-dispersible CePO(4):Tb(3+) nanocrystals were synthesized in aqueous solutions, and characterized by transmission electron microscopy (TEM) and electron diffraction spectroscopy (EDS). We found that both Fe(2+) and Fe(3+) could quench the synchronous fluorescence of CePO(4):Tb(3+) nanocrytals-H(2)O(2) system, but their quenching kinetics velocities were quite different. In the presence of Fe(3+), the synchronous fluorescent intensity was unchanged after only one minute, but in the presence of Fe(2+), the synchronous fluorescent intensity decreased slowly until 28 min later. The Fenton reaction between Fe(2+) and H(2)O(2) resulted in hydroxyl radicals which effectively quenched the synchronous fluorescence of the CePO(4):Tb(3+) nanocrystals due to the oxidation of Ce(3+) into Ce(4+) by hydroxyl radicals. Under optimum conditions, the linear range for Fe(2+) is 3 nM-2 μM, and the limit of detection is 2.0 nM. The method was used to analyze water samples.

  18. Time Management in the Operating Room: An Analysis of the Dedicated Minimally Invasive Surgery Suite

    PubMed Central

    Hsiao, Kenneth C.; Machaidze, Zurab

    2004-01-01

    Background: Dedicated minimally invasive surgery suites are available that contain specialized equipment to facilitate endoscopic surgery. Laparoscopy performed in a general operating room is hampered by the multitude of additional equipment that must be transported into the room. The objective of this study was to compare the preparation times between procedures performed in traditional operating rooms versus dedicated minimally invasive surgery suites to see whether operating room efficiency is improved in the specialized room. Methods: The records of 50 patients who underwent laparoscopic procedures between September 2000 and April 2002 were retrospectively reviewed. Twenty-three patients underwent surgery in a general operating room and 18 patients in an minimally invasive surgery suite. Nine patients were excluded because of cystoscopic procedures undergone prior to laparoscopy. Various time points were recorded from which various time intervals were derived, such as preanesthesia time, anesthesia induction time, and total preparation time. A 2-tailed, unpaired Student t test was used for statistical analysis. Results: The mean preanesthesia time was significantly faster in the minimally invasive surgery suite (12.2 minutes) compared with that in the traditional operating room (17.8 minutes) (P=0.013). Mean anesthesia induction time in the minimally invasive surgery suite (47.5 minutes) was similar to time in the traditional operating room (45.7 minutes) (P=0.734). The average total preparation time for the minimally invasive surgery suite (59.6 minutes) was not significantly faster than that in the general operating room (63.5 minutes) (P=0.481). Conclusion: The amount of time that elapses between the patient entering the room and anesthesia induction is statically shorter in a dedicated minimally invasive surgery suite. Laparoscopic surgery is performed more efficiently in a dedicated minimally invasive surgery suite versus a traditional operating room. PMID:15554269

  19. Emergency Physician Task Switching Increases With the Introduction of a Commercial Electronic Health Record.

    PubMed

    Benda, Natalie C; Meadors, Margaret L; Hettinger, A Zachary; Ratwani, Raj M

    2016-06-01

    We evaluate how the transition from a homegrown electronic health record to a commercial one affects emergency physician work activities from initial introduction to long-term use. We completed a quasi-experimental study across 3 periods during the transition from a homegrown system to a commercially available electronic health record with computerized provider order entry. Observation periods consisted of pre-implementation, 1 month before the implementation of the commercial electronic health record; "go-live" 1 week after implementation; and post-implementation, 3 to 4 months after use began. Fourteen physicians were observed in each period (N=42) with a minute-by-minute observation template to record emergency physician time allocation across 5 task-based categories (computer, verbal communication, patient room, paper [chart/laboratory results], and other). The average number of tasks physicians engaged in per minute was also analyzed as an indicator of task switching. From pre- to post-implementation, there were no significant differences in the amount of time spent on the various task categories. There were changes in time allocation from pre-implementation to go-live and go-live to pre-implementation, characterized by a significant increase in time spent on computer tasks during go-live relative to the other periods. Critically, the number of tasks physicians engaged in per minute increased from 1.7 during pre-implementation to 1.9 during post-implementation (difference 0.19 tasks per minute; 95% confidence interval 0.039 to 0.35). The increase in the number of tasks physicians engaged in per minute post-implementation indicates that physicians switched tasks more frequently. Frequent task switching behavior raises patient safety concerns. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  20. The Effect of Head Massage on the Regulation of the Cardiac Autonomic Nervous System: A Pilot Randomized Crossover Trial.

    PubMed

    Fazeli, Mir Sohail; Pourrahmat, Mir-Masoud; Liu, Mailan; Guan, Ling; Collet, Jean-Paul

    2016-01-01

    To evaluate the effect of a single 10-minute session of Chinese head massage on the activity of the cardiac autonomic nervous system via measurement of heart rate variability (HRV). In this pilot randomized crossover trial, each participant received both head massage and the control intervention in a randomized fashion. The study was conducted at Children's & Women's Health Centre of British Columbia between June and November 2014. Ten otherwise healthy adults (6 men and 4 women) were enrolled in this study. The intervention comprised 10 minutes of head massage therapy (HMT) in a seated position compared with a control intervention of sitting quietly on the same chair with eyes closed for an equal amount of time (no HMT). The primary outcome measures were the main parameters of HRV, including total power (TP), high frequency (HF), HF as a normalized unit, pre-ejection period, and heart rate (HR). A single short session (10 minutes) of head massage demonstrated an increase in TP continuing up to 20 minutes after massage and reaching statistical significance at 10 minutes after massage (relative change from baseline, 66% for HMT versus -6.6% for no HMT; p = 0.017). The effect on HF also peaked up to 10 minutes after massage (59.4% for HMT versus 4% for no HMT; p = 0.139). Receiving head massage also decreased HR by more than three-fold compared to the control intervention. This study shows the potential benefits of head massage by modulating the cardiac autonomic nervous system through an increase in the total variability and a shift toward higher parasympathetic nervous system activity. Randomized controlled trials with larger sample size and multiple sessions of massage are needed to substantiate these findings.

  1. Accelerometer profiles of physical activity and inactivity in normal weight, overweight, and obese U.S. men and women.

    PubMed

    Tudor-Locke, Catrine; Brashear, Meghan M; Johnson, William D; Katzmarzyk, Peter T

    2010-08-03

    The 2005-2006 National Health and Nutrition Examination Survey (NHANES) is used to describe an accelerometer-derived physical activity/inactivity profile in normal weight (BMI < 25 kg/m2), overweight (25 /= 30 kg/m2) U.S. adults. We computed physical activity volume indicators (activity counts/day, uncensored and censored steps/day), rate indicators (e.g., steps/minute), time indicators (employing NHANES activity counts/minute cut points to infer time in non-wear, sedentary, low, light, moderate, and vigorous intensities), the number of breaks in sedentary time (occasions when activity counts rose from < 100 activity/counts in one minute to >/= 100 activity counts in the subsequent minute), achievement of public health guidelines, and classification by step-defined physical activity levels. Data were examined for evidence of consistent and significant gradients across BMI-defined categories. In 2005-2006, U.S adults averaged 6,564 +/- SE 107 censored steps/day, and after considering non-wear time, they spent approximately 56.8% of the rest of the waking day in sedentary time, 23.7% in low intensity, 16.7% in light intensity, 2.6% in moderate intensity, and 0.2% in vigorous intensity. Overall, approximately 3.2% of U.S. adults achieved public health guidelines. The normal weight category took 7,190 +/- SE 157 steps/day, and spent 25.7 +/- 0.9 minutes/day in moderate intensity and 7.3 +/- 0.4 minutes/day in vigorous intensity physical activity. The corresponding numbers for the overweight category were 6,879 +/- 140 steps/day, 25.3 +/- 0.9 minutes/day, and 5.3 +/- 0.5 minutes/day and for the obese category 5,784 +/- 124 steps/day, 17.3 +/- 0.7 minutes/day and 3.2 +/- 0.4 minutes/day. Across BMI categories, increasing gradients and significant trends were apparent in males for sedentary time and decreasing gradients and significant trends were evident in time spent in light intensity, moderate intensity, and vigorous intensity. For females, there were only consistent gradients and significant trends apparent for decreasing amounts of time spent in moderate and vigorous intensity. Simple indicators of physical activity volume (i.e., steps/day) and time in light, moderate or vigorous intensity physical activity differ across BMI categories for both sexes, suggesting that these should continue to be targets for surveillance.

  2. Detection of low-concentration host mRNA transcripts in Malawian children at risk for environmental enteropathy

    USDA-ARS?s Scientific Manuscript database

    Transcriptomic analysis of fecal samples is an emerging method for the diagnosis of gastrointestinal pathology because it is noninvasive and requires minute volumes of analyte; however, detection of mRNA in low copy numbers in human stool is challenging. Our objective was to develop a method for det...

  3. A 15.7-Minute AM CVn Binary Discovered in K2

    NASA Astrophysics Data System (ADS)

    Green, M. J.; Hermes, J. J.; Marsh, T. R.; Steeghs, D. T. H.; Bell, Keaton J.; Littlefair, S. P.; Parsons, S. G.; Dennihy, E.; Fuchs, J. T.; Reding, J. S.; Kaiser, B. C.; Ashley, R. P.; Breedt, E.; Dhillon, V. S.; Gentile Fusillo, N. P.; Kerry, P.; Sahman, D. I.

    2018-04-01

    We present the discovery of SDSS J135154.46-064309.0, a short-period variable observed using 30-minute cadence photometry in K2 Campaign 6. Follow-up spectroscopy and high-speed photometry support a classification as a new member of the rare class of ultracompact accreting binaries known as AM CVn stars. The spectroscopic orbital period of 15.65 ± 0.12 minutes makes this system the fourth-shortest period AM CVn known, and the second system of this type to be discovered by the Kepler spacecraft. The K2 data show photometric periods at 15.7306 ± 0.0003 minutes, 16.1121 ± 0.0004 minutes and 664.82 ± 0.06 minutes, which we identify as the orbital period, superhump period, and disc precession period, respectively. From the superhump and orbital periods we estimate the binary mass ratio q = M2/M1 = 0.111 ± 0.005, though this method of mass ratio determination may not be well calibrated for helium-dominated binaries. This system is likely to be a bright foreground source of gravitational waves in the frequency range detectable by LISA, and may be of use as a calibration source if future studies are able to constrain the masses of its stellar components.

  4. Design Modification of Electrophoretic Equipment

    NASA Technical Reports Server (NTRS)

    Reddick, J. M.; Hirsch, I.

    1973-01-01

    The improved design of a zone electrophoretic sampler is reported that can be used in mass screening for hemoglobin S, the cause of sickle cell anemia. Considered is a high voltage multicell cellulose acetate device that requires 5 to 6 minutes electrophoresis periods; cells may be activitated individually or simultaneously. A multisample hemoglobin applicator standardizes the amount of sample applied and transfers the homolysate to the electrical wires.

  5. A STUDY OF THE EFFECTS OF PRESENTING INFORMATIVE SPEECHES WITH AND WITHOUT THE USE OF VISUAL AIDS TO VOLUNTARY ADULT AUDIENCES.

    ERIC Educational Resources Information Center

    BODENHAMER, SCHELL H.

    TO DETERMINE THE COMPARATIVE AMOUNT OF LEARNING THAT OCCURRED AND THE AUDIENCE REACTION TO MEETING EFFECTIVENESS, A 20-MINUTE INFORMATIVE SPEECH, "THE WEATHER," WAS PRESENTED WITH VISUAL AIDS TO 23 AND WITHOUT VISUAL AIDS TO 23 INFORMAL, VOLUNTARY, ADULT AUDIENCES. THE AUDIENCES WERE RANDOMLY DIVIDED, AND CONTROLS WERE USED TO ASSURE IDENTICAL…

  6. Create an Adventure Challenge: Using Recess Time to Supplement Physical Activity during the School Day

    ERIC Educational Resources Information Center

    DiGiacinto, Kacey Lynn; Jones, Emily

    2010-01-01

    NASPE recommends children ages 5-12 accumulate at least 60 minutes of moderate to vigorous physical activity each day of the week. With the growing occurrence of obesity in the United States, it is clear that too many of America's youth are not meeting the recommended amount of daily physical activity. Given that America's youth are having…

  7. Parent-Child Quality Time: Does Birth Order Matter?

    ERIC Educational Resources Information Center

    Price, Joseph

    2008-01-01

    Using data from the American Time Use Survey, I find that a first-born child receives 20-30 more minutes of quality time each day with his or her parent than a second-born child of the same age from a similar family. The birth-order difference results from parents giving roughly equal time to each child at any point in time while the amount of…

  8. Identification of the Optimal Protocol for Automated Office Blood Pressure Measurement Among Patients With Treated Hypertension.

    PubMed

    Moore, Myles N; Schultz, Martin G; Nelson, Mark R; Black, J Andrew; Dwyer, Nathan B; Hoban, Ella; Jose, Matthew D; Kosmala, Wojciech; Przewlocka-Kosmala, Monika; Zachwyc, Jowita; Otahal, Petr; Picone, Dean S; Roberts-Thomson, Philip; Veloudi, Panagiota; Sharman, James E

    2018-02-09

    Automated office blood pressure (AOBP) involving repeated, unobserved blood pressure (BP) readings during one clinic visit is recommended for in-office diagnosis and assessment of hypertension. However, the optimal AOBP protocol to determine BP control in the least amount of time with the fewest BP readings is yet to be determined and was the aim of this study. One hundred and eighty-nine patients (mean age 62.8 ± 12.1 years; 50.3% female) with treated hypertension referred to specialist clinics at 2 sites underwent AOBP in a quiet room alone. Eight BP measurements were taken starting immediately after sitting and then at 2-minute intervals (15 minutes total). The optimal AOBP protocol was defined by the smallest mean difference and highest intraclass correlation coefficient (ICC) compared with daytime ambulatory BP (ABP). The same BP device (Mobil-o-graph, IEM) was used for both AOBP and daytime ABP. Average 15-minute AOBP and daytime ABP were 134 ± 22/82 ± 13 and 137 ± 17/83 ± 11 mm Hg, respectively. The optimal AOBP protocol was derived within a total duration of 6 minutes from the average of 2 measures started after 2 and 4 minutes of seated rest (systolic BP: mean difference (95% confidence interval) 0.004(-2.21, 2.21) mm Hg, P = 1.0; ICC = 0.81; diastolic BP: mean difference 0.37(-0.90, 1.63) mm Hg, P = 0.57; ICC = 0.86). AOBP measures taken after 8 minutes tended to underestimate daytime ABP (whether as a single BP or the average of more than 1 BP reading). Only 2 AOBP readings taken over 6 minutes (excluding an initial reading immediately after sitting) may be needed to be comparable with daytime ABP. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  9. The effect of topical anesthetic hydration on the depth of thermal injury from the plasma skin regeneration device.

    PubMed

    Sanderson, Alicia R; Wu, Edward C; Liaw, Lih-Huei L; Garg, Rohit; Gangnes, Richard A

    2014-02-01

    The plasma skin regeneration (PSR) device delivers thermal energy to the skin by converting nitrogen gas to plasma. Prior to treatment, hydration of the skin is recommended as it is thought to limit the zone of thermal damage. However, there is limited data on optimal hydration time. This pilot study aims to determine the effect of topical anesthetic application time on the depth of thermal injury from a PSR device using histology. PSR (1.8 and 3.5 J) was performed after 0, 30, or 60 minutes of topical anesthetic application. Rhytidectomy was then performed and skin was fixed for histologic analysis. Four patients (two control and four treatment sites per patient) undergoing rhytidectomy were recruited for the study. Each patient served as his/her own control (no hydration). A scoring system for tissue injury was developed. Epidermal injury, the presence of vacuolization, blistering, damage to adnexal structures, and depth of dermal collagen changes were evaluated in over 1,400 high-power microscopy fields. There was a significant difference in the average thermal injury score, depth of thermal damage, and epidermal injury when comparing controls to 30 minutes of hydration (P = 0.012, 0.012, 0.017, respectively). There was no statistical difference between controls and 60 minutes of hydration or between 30 and 60 minutes of hydration. Epidermal vacuolization at low energy and patchy distribution of thermal injury was also observed. Topical hydration influences the amount of thermal damage when applied to skin for 30 minutes prior to treatment with the PSR device. There was a trend toward decreasing thermal damage at 60 minutes, and there was no difference between treatment for 30 or 60 minutes. The data suggest that application of topical anesthetic for a short period of time prior to treatment with the PSR device is cost-effective, safe, and may be clinically beneficial. © 2013 Wiley Periodicals, Inc.

  10. Impact of cap-assisted colonoscopy on the learning curve and quality in colonoscopy: a randomized controlled trial.

    PubMed

    Tang, Zhouwen; Zhang, Daniel S; Thrift, Aaron P; Patel, Kalpesh K

    2018-03-01

    Colonoscopy competency assessment in trainees traditionally has been informal. Comprehensive metrics such as the Assessment of Competency in Endoscopy (ACE) tool suggest that competency thresholds are higher than assumed. Cap-assisted colonoscopy (CAC) may improve competency, but data regarding novice trainees are lacking. We compared CAC versus standard colonoscopy (SC) performed by novice trainees in a randomized controlled trial. All colonoscopies performed by 3 gastroenterology fellows without prior experience were eligible for the study. Exclusion criteria included patient age <18 or >90 years, pregnancy, prior colon resection, diverticulitis, colon obstruction, severe hematochezia, referral for EMR, or a procedure done without patient sedation. Patients were randomized to either CAC or SC in a 1:1 fashion. The primary outcome was the independent cecal intubation rate (ICIR). Secondary outcomes were cecal intubation time, polyp detection rate, polyp miss rate, adenoma detection rate, ACE tool scores, and cumulative summation learning curves. A total of 203 colonoscopies were analyzed, 101 in CAC and 102 in SC. CAC resulted in a significantly higher cecal intubation rate, at 79.2% in CAC compared with 66.7% in SC (P = .04). Overall cecal intubation time was significantly shorter at 13.7 minutes for CAC versus 16.5 minutes for SC (P =.02). Cecal intubation time in the case of successful independent fellow intubation was not significantly different between CAC and SC (11.6 minutes vs 12.7 minutes; P = .29). Overall ACE tool motor and cognitive scores were higher with CAC. Learning curves for ICIR approached the competency threshold earlier with cap use but reached competency for only 1 fellow. The polyp detection rate, polyp miss rate, and adenoma detection rate were not significantly different between groups. CAC resulted in significant improvement in ICIR, overall ACE tool scores, and trend toward competency on learning curves when compared with SC in colonoscopy trainees without prior colonoscopy experience. (Clinical trial registration number: NCT02472730.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Pharmacokinetics and pharmacodynamics of smoked heroin.

    PubMed

    Jenkins, A J; Keenan, R M; Henningfield, J E; Cone, E J

    1994-10-01

    Despite the current popularity of smoking as a route of drug self-administration, there have been few human studies characterizing the pharmacokinetics and pharmacodynamics of smoked drugs of abuse. A variety of technological difficulties are encountered in the design of smoking studies, such as delivering reproducible doses and limiting the amount of pyrolysis of parent drug. As part of a concerted research effort to deliver precise, smoked doses of drug, a computer-assisted smoking device was utilized that delivered single puffs of heroin vapor to human subjects under controlled clinical conditions. Recovery studies indicated that the smoking device delivered approximately 89% of parent heroin to subjects. Although only two qualified heroin smokers could be identified as eligible volunteers, their participation provided the unique opportunity to study the pharmacokinetics and pharmacodynamics of smoked heroin. The two subjects were administered four smoked heroin doses in ascending order. In addition, four intravenous doses of heroin were administered for comparison of effects and estimation of bioavailability. Concurrent physiological, behavioral, and performance measures were collected along with blood samples. Blood was analyzed for heroin, 6-acetylmorphine, and morphine by solid-phase extraction gas chromatography-mass spectrometry. Heroin appeared rapidly in blood after administration and peaked 1-5 minutes after smoking, which is similar to that observed following intravenous administration. Heroin concentrations declined rapidly to the limit of detection (1.0 ng/mL) by 30 minutes. 6-Acetylmorphine blood concentrations also peaked and declined rapidly after smoked heroin with peak concentrations occurring at 1-2 minutes after smoking. Morphine levels rose and decayed more slowly. Mean elimination half-lives for heroin, 6-acetylmorphine, and morphine were 3.3 min, 5.4 min, and 18.8 min, respectively, by the smoked route. The bioavailability of smoked heroin was highly variable. Physiological measures such as pupil diameter demonstrated a counterclockwise hysteresis compared with heroin blood levels. The rapid onset of pharmacological effects together with the early appearance of heroin and metabolites in blood following smoked heroin demonstrated the effectiveness of this route of drug administration. It is evident that the smoking route enables individuals to obtain similar pharmacological effects as are produced by intravenous administration of heroin.

  12. Spectral analysis method for detecting an element

    DOEpatents

    Blackwood, Larry G [Idaho Falls, ID; Edwards, Andrew J [Idaho Falls, ID; Jewell, James K [Idaho Falls, ID; Reber, Edward L [Idaho Falls, ID; Seabury, Edward H [Idaho Falls, ID

    2008-02-12

    A method for detecting an element is described and which includes the steps of providing a gamma-ray spectrum which has a region of interest which corresponds with a small amount of an element to be detected; providing nonparametric assumptions about a shape of the gamma-ray spectrum in the region of interest, and which would indicate the presence of the element to be detected; and applying a statistical test to the shape of the gamma-ray spectrum based upon the nonparametric assumptions to detect the small amount of the element to be detected.

  13. IS GUTTACORE MORE EASILY REMOVED FROM THE ROOT CANAL THAN THERMAFIL? AN EX-VIVO STUDY.

    PubMed

    Nevares, Giselle; de Albuquerque, Diana Santana; Bueno, Carlos Eduardo da Silveira; Cunha, Rodrigo Sanches

    2015-01-01

    GuttaCore is a new cross-linked gutta-percha carrier. Its handling time and ease of removal were compared with those of a plastic carrier (Thermafil) and the continuous wave of condensation technique (control). Forty-five maxillary central incisors were randomly divided 3 groups according to filling technique and retreatment was carried out in all samples with NiTi rotary files, hand files and ultrasonic inserts. Time required for filling removal was recorded. Roots were then split longitudinally and photographed under 5x magnification, and residual filling material was quantified. Removal time was significantly longer for Thermafil (7.10 minutes) than GuttaCore (2.91 minutes) and the control group (1.93 minutes) (p < 0.001). The amount of residual filling material did not differ among the groups: Thermafil 8.31%, GuttaCore 6.27 and control 8.68% (p > 0.05). In conclusion, replacing plastic core with cross-linked gutta-percha allows easier removal of carrier from the root canal. The remnants of filling material in all samples illustrate that retreatment remains a challenge in endodontics.

  14. Effects of catecholamines on rat myocardial metabolism. I. Influence of catecholamines on energy-rich nucleotides and phosphorylated fraction contents.

    PubMed

    Merouze, P; Gaudemer, Y

    1975-01-01

    1. The influence of catecholamines (adrenaline and noradrenaline) on energy metabolism of the rat myocardium has been studied by incubating slices of this tissue with these hormones and by following the levels of the different phosphorylated fractions and adenylic nucleotides. 2. Similar effects are obtained with both hormones, adrenaline being more effective. 3. Catecholamines decrease significantly the total amount of phosphate while Pi content increases during the first 10 minutes of incubation; labile and residual phosphate contents increase at the beginning of incubation and decrease to the initial values afterwards. 4. ATP and ADP levels decrease significantly with both hormones; however, the effect of noradrenalin on the ATP level needs a longer time of incubation. The ATP/ADP ratios decrease after 5 minutes incubation and the total adenylic nucleotide content is severely decreased (35 per cent with adrenalin, after 20 minutes incubation). 5. Similar results have been obtained with other tissues; these results can explain the decrease of aerobic metabolism we observed under the same conditions.

  15. Decontamination Efficacy of Ultraviolet Radiation against Biofilms of Common Nosocomial Bacteria.

    PubMed

    Tingpej, Pholawat; Tiengtip, Rattana; Kondo, Sumalee

    2015-06-01

    Ultraviolet radiation (UV) is commonly used to destroy microorganisms in the health-care environment. However, the efficacy of UV radiation against bacteria growing within biofilms has never been studied. To measure the sterilization effectiveness of UV radiation against common healthcare associated pathogens growing within biofilms. Staphylococcus aureus, Methicillin-resistant S. aureus (MRSA), Streptococcus epidermidis, Escherichia coli, ESBL-producing E. coli, Pseudomonas aeruginosa and Acinetobacter baumannii were cultivated in the Calgary Biofilm Device. Their biofilms were placed 50 cm from the UV lamp within the Biosafety Cabinet. Viability test, crystal violet assay and a scanning electron microscope were used to evaluate the germicidal efficacy. Within 5 minutes, UV radiation could kill S. aureus, MRSA, S. epidermidis, A. baumannii and ESBL-producing E. coli completely while it required 20 minutes and 30 minutes respectively to kill E. coli and P. aeruginosa. However, the amounts of biomass and the ultrastructure between UV-exposed biofilms and controls were not significantly different. UV radiation is effective in inactivating nosocomial pathogens grown within biofilms, but not removing biofilms and EPS. The biofilm of P. aeruginosa was the most durable.

  16. Influence of temperature and brewing time of nettle (Urtica dioica L.) infusions on vitamin C content

    PubMed

    Wolska, Jolanta; Czop, Michał; Jakubczyk, Karolina; Janda, Katarzyna

    Stinging nettle (Urtica dioica L.) can be found in temperate climate zones of Europe, Africa and America Nettle may be a source of nutritional ingredients, mineral salts, vitamins and antioxidants. The aim of the study was to determine the effect of temperature and brewing time Urtica dioica L. infusions from different parts of this plant on vitamin C (ascorbic acid) content. Infusions of nettle leaf, stem and root were prepared at room temperature, 50°C, 60°C, 70°C and 80°C for 10 minutes. Leaf infusions were also brewed for 5, 10, 15 and 20 minutes at initial water temperature of 60°C. The amount of vitamin C was determined by the spectrophotometric method. The best temperature of brewing nettle infusions, in terms of vitamin C concentration, is between 50 °C and 60 °C as it is sufficient to extract the substance, yet not high enough to destroy it. The optimal time of brewing appeared to be 10 minutes as the prolonged exposure to high temperature appeared to be detrimental for ascorbic acid as well.

  17. NaCl as a solid solvent to assist the mechanochemical synthesis and post-synthesis of hierarchical porous MOFs with high I2 vapour uptake.

    PubMed

    Yang, Junyi; Feng, Xiao; Lu, Guangnong; Li, Yulin; Mao, Chaochao; Wen, Zhongliang; Yuan, Wenbing

    2018-04-03

    The use of salts as grinding media to assist the mechanosynthesis, and the following one-pot mechanochemical post-synthesis, of hierarchically porous MOFs was carried out efficiently by ball milling. NaCl or KCl were used as a solid solvent to initially pre-grind with 1,3,5-benzenetricarboxylic acid (H3BTC) and copper acetate monhydrate, respectively, for 1 minute, then both mixtures were combined together for a further 20 minutes of grinding, and the resultant mixture was finally washed with ethanol and water to obtain the hierarchically micro-, meso- and macroporous HKUST-1 with a high yield. Moreover, the post-synthesis of these as-obtained hierarchically porous HKUST-1 was easily performed via grinding triethylenediamine (TED) with the above unwashed crude-products for 20 minutes. By adjusting the amount of NaCl and TED added, we simply fabricated the pore- and function-adjustable hierarchically porous HKUST-1. Furthermore, these as-obtained HKUST-1 products showed high performance in the capture of volatile iodine.

  18. Pulse labeling of RNA of mammalian cells.

    PubMed

    Rovera, G; Berman, S; Baserga, R

    1970-04-01

    When cells from a hypotetraploid strain of Ehrlich ascites tumor are exposed to uridine-(3)H either in vivo or in vitro, the amount of radioactivity incorporated into RNA reaches a maximum within ten minutes, after which any further incorporation stops. (3)H-uridine triphosphate disappears from the acid soluble pool within 30 minutes and the findings indicate that the RNA of these cells can be pulse labeled without the use of any antibiotic or the need of a "chase." The stability of the pulse labeled RNA in the presence of pentobarbital (an inhibitor of RNA synthesis) indicates the virtual absence of RNA breakdown. However, actinomycin D, at a dosage of 250 mug/mouse in vivo and 10 mug/ml in vitro produces breakdown of labeled RNA, thus confirming earlier observations that the drug is not a suitable tool for RNA kinetics determinations. The pulse-labeled RNA leaves the nucleus slowly and some radioactive RNA is still present in the nuclear fraction after 24 hours. Radioactivity begins to appear in cytoplasmic ribosomal RNA after 20 minutes and continues to increase up to six hours.

  19. Multicenter prospective evaluation of the express view reading mode for small-bowel capsule endoscopy studies.

    PubMed

    Saurin, Jean-Christophe; Jacob, Philippe; Heyries, Laurent; Pesanti, Christian; Cholet, Franck; Fassler, Isaac; Boulant, James; Bramli, Slim; De Leusse, Antoin; Rahmi, Gabriel

    2018-05-01

     Reducing the reading time of capsule endoscopy films is of high priority for gastroenterologists. We report a prospective multicenter evaluation of an "express view" reading mode (Intromedic capsule system).  Eighty-three patients with obscure gastrointestinal bleeding were prospectively included in 10 centers. All patients underwent small-bowel capsule endoscopy (Intromedic, Seoul, Republic of Korea). Films were read in standard mode, then a second reading was performed in express view mode at a second center. For each lesion, the precise location, nature, and relevance were collected. A consensus reading and review were done by three experts, and considered to be the gold standard.  The mean reading time of capsule films was 39.7 minutes (11 - 180 minutes) and 19.7 minutes (4 - 40 minutes) by standard and express view mode, respectively ( P  < 1 × 10  - 4 ). The consensus review identified a significant lesion in 44/83 patients (53.0 %). Standard reading and express view reading had a 93.3 % and 82.2 % sensitivity, respectively (NS). Consensus review identified 70 significant images from which standard reading and express view reading detected 58 (82.9 %) and 55 (78.6 %), respectively. The informatics algorithm detected 66/70 images (94.3 %) thus missing four small-bowel angiodysplasia.  The express view algorithm allows an important shortening of Intromedic capsule film reading time with a high sensitivity.

  20. Degassing Processes at Persistently Active Explosive Volcanoes

    NASA Astrophysics Data System (ADS)

    Smekens, Jean-Francois

    Among volcanic gases, sulfur dioxide (SO2) is by far the most commonly measured. More than a monitoring proxy for volcanic degassing, SO 2 has the potential to alter climate patterns. Persistently active explosive volcanoes are characterized by short explosive bursts, which often occur at periodic intervals numerous times per day, spanning years to decades. SO 2 emissions at those volcanoes are poorly constrained, in large part because the current satellite monitoring techniques are unable to detect or quantify plumes of low concentration in the troposphere. Eruption plumes also often show high concentrations of ash and/or aerosols, which further inhibit the detection methods. In this work I focus on quantifying volcanic gas emissions at persistently active explosive volcanoes and their variations over short timescales (minutes to hours), in order to document their contribution to natural SO2 flux as well as investigate the physical processes that control their behavior. In order to make these measurements, I first develop and assemble a UV ground-based instrument, and validate it against an independently measured source of SO2 at a coal-burning power plant in Arizona. I establish a measurement protocol and demonstrate that the instrument measures SO 2 fluxes with < 20 % error. Using the same protocol, I establish a record of the degassing patterns at Semeru volcano (Indonesia), a volcano that has been producing cycles of repeated explosions with periods of minutes to hours for the past several decades. Semeru produces an average of 21-71 tons of SO2 per day, amounting to a yearly output of 8-26 Mt. Using the Semeru data, along with a 1-D transient numerical model of magma ascent, I test the validity of a model in which a viscous plug at the top of the conduit produces cycles of eruption and gas release. I find that it can be a valid hypothesis to explain the observed patterns of degassing at Semeru. Periodic behavior in such a system occurs for a very narrow range of conditions, for which the mass balance between magma flux and open-system gas escape repeatedly generates a viscous plug, pressurizes the magma beneath the plug, and then explosively disrupts it.

  1. Shorter sleep duration is associated with social impairment and comorbidities in ASD.

    PubMed

    Veatch, Olivia J; Sutcliffe, James S; Warren, Zachary E; Keenan, Brendan T; Potter, Melissa H; Malow, Beth A

    2017-07-01

    Sleep disturbance, particularly insomnia, is common in children with autism spectrum disorders (ASD). Furthermore, disturbed sleep affects core symptoms and other related comorbidities. Understanding the causes and consequences of sleep disturbances in children with ASD is an important step toward mitigating these symptoms. To better understand the connection between sleep duration and ASD severity, we analyzed ASD-related symptoms using the Autism Diagnostic Interview-Revised (ADI-R), Autism Diagnostic Observation Schedule (ADOS), IQ scores, and parent reports of the average amount of time slept per night that were available in the medical histories of 2,714 children with ASD in the Simons Simplex Collection (SSC). The mean (SD) sleep duration was 555 minutes. Sleep duration and severity of core ASD symptoms were negatively correlated, and sleep duration and IQ scores were positively correlated. Regression results indicated that more severe social impairment, primarily a failure to develop peer relationships, is the core symptom most strongly associated with short sleep duration. Furthermore, increased severity for numerous maladaptive behaviors assessed on the Child Behavior Checklist, as well as reports of attention deficit disorder, depressive disorder, and obsessive compulsive disorder were associated with short sleep duration. Severity scores for social/communication impairment and restricted and repetitive behaviors (RRB) were increased, and IQ scores were decreased, for children reported to sleep ≤420 minutes per night (lower 5th percentile) compared to children sleeping ≥660 minutes (upper 95th percentile). Our results indicate that reduced amounts of sleep are related to more severe symptoms in children with ASD. Autism Res 2017. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. Autism Res 2017, 10: 1221-1238. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.

  2. The 6-min mastication test: a unique test to assess endurance of continuous chewing, normal values, reliability, reproducibility and usability in patients with mitochondrial disease.

    PubMed

    van den Engel-Hoek, L; Knuijt, S; van Gerven, M H J C; Lagarde, M L J; Groothuis, J T; de Groot, I J M; Janssen, M C H

    2017-03-01

    In patients with mitochondrial disease, fatigue and muscle problems are the most common complaints. They also experience these complaints during mastication. To measure endurance of continuous mastication in patients with mitochondrial diseases, the 6-min mastication test (6MMT) was developed. This study included the collection of normal data for the 6MMT in a healthy population (children and adults). During 6 min of continuous mastication on a chew tube chewing cycles per minute, total amount of chewing cycles and the difference between minute 1 (M 1 ) and minute 6 (M 2 ) were collected in 271 healthy participants (5-80 years old). These results were compared with those of nine paediatric and 25 adult patients with a mitochondrial disease. Visual analogue scale (VAS) scores were collected directly after the test and after 5 min. A qualitative rating was made on masticatory movements. The reproducibility of the 6MMT in the healthy population with an interval of approximately 2 weeks was good. The inter-rater reliability for the observations was excellent. The patient group demonstrated lower total amount of chewing cycles or had greater differences between M 1 and M 6 . The 6MMT is a reliable and objective test to assess endurance of continuous chewing. It demonstrates the ability of healthy children and adults to chew during 6 min with a highly stable frequency of mastication movements. The test may give an explanation for the masticatory problems in patient groups, who are complaining of pain and fatigue during mastication. © 2017 John Wiley & Sons Ltd.

  3. Unsupervised Online Classifier in Sleep Scoring for Sleep Deprivation Studies

    PubMed Central

    Libourel, Paul-Antoine; Corneyllie, Alexandra; Luppi, Pierre-Hervé; Chouvet, Guy; Gervasoni, Damien

    2015-01-01

    Study Objective: This study was designed to evaluate an unsupervised adaptive algorithm for real-time detection of sleep and wake states in rodents. Design: We designed a Bayesian classifier that automatically extracts electroencephalogram (EEG) and electromyogram (EMG) features and categorizes non-overlapping 5-s epochs into one of the three major sleep and wake states without any human supervision. This sleep-scoring algorithm is coupled online with a new device to perform selective paradoxical sleep deprivation (PSD). Settings: Controlled laboratory settings for chronic polygraphic sleep recordings and selective PSD. Participants: Ten adult Sprague-Dawley rats instrumented for chronic polysomnographic recordings Measurements: The performance of the algorithm is evaluated by comparison with the score obtained by a human expert reader. Online detection of PS is then validated with a PSD protocol with duration of 72 hours. Results: Our algorithm gave a high concordance with human scoring with an average κ coefficient > 70%. Notably, the specificity to detect PS reached 92%. Selective PSD using real-time detection of PS strongly reduced PS amounts, leaving only brief PS bouts necessary for the detection of PS in EEG and EMG signals (4.7 ± 0.7% over 72 h, versus 8.9 ± 0.5% in baseline), and was followed by a significant PS rebound (23.3 ± 3.3% over 150 minutes). Conclusions: Our fully unsupervised data-driven algorithm overcomes some limitations of the other automated methods such as the selection of representative descriptors or threshold settings. When used online and coupled with our sleep deprivation device, it represents a better option for selective PSD than other methods like the tedious gentle handling or the platform method. Citation: Libourel PA, Corneyllie A, Luppi PH, Chouvet G, Gervasoni D. Unsupervised online classifier in sleep scoring for sleep deprivation studies. SLEEP 2015;38(5):815–828. PMID:25325478

  4. Novel sensitive monoclonal antibody based competitive enzyme-linked immunosorbent assay for the detection of raw and processed bovine beta-casein

    PubMed Central

    Castillo, Daniela S.

    2017-01-01

    Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention. PMID:28759641

  5. Novel sensitive monoclonal antibody based competitive enzyme-linked immunosorbent assay for the detection of raw and processed bovine beta-casein.

    PubMed

    Castillo, Daniela S; Cassola, Alejandro

    2017-01-01

    Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention.

  6. OH detection by Ford Motor Company

    NASA Technical Reports Server (NTRS)

    Wang, Charles C.

    1986-01-01

    Two different methods for detection of OH are presented: a low pressure flow cell system and a frequency modulation absorption measurement. Using conventional absorption spectroscopy, detection limits were quoted of 1,000,000 OH molecules per cu cm using a 30-minute averaging time on the ground, and a 3-hour averaging time in the air for present apparatus in use. With the addition of FM spectroscopy at 1 GHz, a double-beam machine should permit detectable absorption of and an OH limit of 100,000 per cu cm in a 30-minute averaging time. In the low pressure system on which experiments are ongoing nonexponential time behavior was observed after the decay had progressed to about 0.3 of its original level; this was attributed to ion emission in the photomultiplier. A flame source with OH present at high concentration levels was used as a calibration. It was estimated that within the sampling chamber, 400,000 OH could be measured. With a factor-of-2 loss at the sampling orifice, this means detectability of 5 to 8 x 100,000 cu cm at the present time. This could be reduced by a factor of 2 in one hour averaging time; improvements in laser bandwidth and energy should provide another factor of 2 in sensitivity.

  7. OH detection by Ford Motor Company

    NASA Astrophysics Data System (ADS)

    Wang, Charles C.

    1986-12-01

    Two different methods for detection of OH are presented: a low pressure flow cell system and a frequency modulation absorption measurement. Using conventional absorption spectroscopy, detection limits were quoted of 1,000,000 OH molecules per cu cm using a 30-minute averaging time on the ground, and a 3-hour averaging time in the air for present apparatus in use. With the addition of FM spectroscopy at 1 GHz, a double-beam machine should permit detectable absorption of and an OH limit of 100,000 per cu cm in a 30-minute averaging time. In the low pressure system on which experiments are ongoing nonexponential time behavior was observed after the decay had progressed to about 0.3 of its original level; this was attributed to ion emission in the photomultiplier. A flame source with OH present at high concentration levels was used as a calibration. It was estimated that within the sampling chamber, 400,000 OH could be measured. With a factor-of-2 loss at the sampling orifice, this means detectability of 5 to 8 x 100,000 cu cm at the present time. This could be reduced by a factor of 2 in one hour averaging time; improvements in laser bandwidth and energy should provide another factor of 2 in sensitivity.

  8. A preliminary study on the reduction of limonite ore by using rice husk as a reducing agent

    NASA Astrophysics Data System (ADS)

    Maksum, Ahmad; Husein, Michael Kelvin E.; Permana, Sulaksana; Rustandi, Andi; Wahyuadi Soedarsono, Johny

    2018-03-01

    The abundant of rice husk in Indonesia has encouraged researchers to study the feasibility of rice husk for substituting material that is more expensive or dangerous. In previous study, silica with a purity of 99.9% has been obtained from rice husk with calcinations process. Nevertheless, the gases resulting from the process were not used and left useless. Therefore, in this study, those gases derived from rice husk calcinations process were used as reducing agents during the ferronickel (Fe-Ni) production through a direct reduction process. The objective of this study was to investigate the effect of the amount of rice husk in the pellets on the increase of nickel content in the limonite reduction process. The limonite ore were crushed to the size of less than 150 mesh using disc-mill, and then were mixed with rice husk powder (10, 20, 30 in wt % mass) before being pelletized using bentonite as a binder. The resulted pellets were roasted at 500°C for 60 minutes and then quenched in water media. After drying process, the reduction process of 40g pellets was conducted at 1000°C for 90 minutes with 20g rice husk in furnace. The effects of additional rice husk on the direct reduction of limonite ore pellets were qualitatively analyzed by using X-ray powder diffraction (XRD) and quantitatively by Atomic absorption spectroscopy (AAS). Both analysis results showed that the reduction process followed the reaction scheme: Fe2O3→Fe3O4→FeO and NiO phase was detected in the sample with 20% rice husk addition. The optimum concentration of Ni 1.23% was obtained for 20% rice husk addition.

  9. Metabolic heterogeneity in human calf muscle during maximal exercise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vandenborne, K.; McCully, K.; Kakihira, H.

    1991-07-01

    Human skeletal muscle is composed of various muscle fiber types. The authors hypothesized that differences in metabolism between fiber types could be detected noninvasively with {sup 31}P nuclear magnetic resonance spectroscopy during maximal exercise. This assumes that during maximal exercise all fiber types are recruited and all vary in the amount of acidosis. The calf muscles of seven subjects were studied. Two different coils were applied: an 11-cm-diameter surface coil and a five-segment meander coil. The meander coil was used to localize the {sup 31}P signal to either the medial or the lateral gastrocnemius. Maximal exercise, consisting of rapid plantarmore » flexions, resulted in an 83.7% {plus minus} 7.8% decrease of the phosphocreatine pool and an 8-fold increase of the inorganic phosphate (P{sub i}) pool. At rest the P{sub i} pool was observed as a single resonance (pH 7.0). Toward the end of the first minute of exercise, three subjects showed three distinct P{sub i} peaks. During the second minute of exercise the pH values stabilized. The same pattern was seen when the signal was collected from the medial or lateral gastrocnemius. In four subjects only two distinct P{sub i} peaks were observed. The P{sub i} peaks had differing relative areas in different subjects, but they were reproducible in each individual. This method allowed is to study the appearance and disappearance of the different P{sub i} peaks, together with the changes in pH. Because multiple P{sub i} peaks were seen in single muscles they most likely identify different muscle fiber types.« less

  10. Hubble Eyes a Powerful Galaxy

    NASA Image and Video Library

    2017-06-30

    Not all galaxies have the luxury of possessing a simple moniker or quirky nickname. This impressive galaxy imaged by the NASA/ESA Hubble Space Telescope is one of the unlucky ones, and goes by a name that looks more like a password for a computer: 2XMM J143450.5+033843. Such a name may seem like a random jumble of numbers and letters, but like all galactic epithets it has a distinct meaning. This galaxy, for example, was detected and observed as part of the second X-ray sky survey performed by ESA’s XMM-Newton Observatory. Its celestial coordinates form the rest of the bulky name, following the “J”: a right ascension value of 14h (hours) 34m (minutes) 50.5s (seconds). This can be likened to terrestrial longitude. It also has a declination of +03d (degrees) 38m (minutes) 43s (seconds). Declination can be likened to terrestrial latitude. The other fuzzy object in the frame was named in the same way — it is a bright galaxy named 2XMM J143448.3+033749. 2XMM J143450.5+033843 lies nearly 400 million light-years away from Earth. It is a Seyfert galaxy that is dominated by something known as an Active Galactic Nucleus — its core is thought to contain a supermassive black hole that is emitting huge amounts of radiation, pouring energetic X-rays out into the Universe. Photo credit: ESA/Hubble & NASA NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  11. Detection of tiny amounts of fissile materials in large-sized containers with radioactive waste

    NASA Astrophysics Data System (ADS)

    Batyaev, V. F.; Skliarov, S. V.

    2018-01-01

    The paper is devoted to non-destructive control of tiny amounts of fissile materials in large-sized containers filled with radioactive waste (RAW). The aim of this work is to model an active neutron interrogation facility for detection of fissile ma-terials inside NZK type containers with RAW and determine the minimal detectable mass of U-235 as a function of various param-eters: matrix type, nonuniformity of container filling, neutron gen-erator parameters (flux, pulse frequency, pulse duration), meas-urement time. As a result the dependence of minimal detectable mass on fissile materials location inside container is shown. Nonu-niformity of the thermal neutron flux inside a container is the main reason of the space-heterogeneity of minimal detectable mass in-side a large-sized container. Our experiments with tiny amounts of uranium-235 (<1 g) confirm the detection of fissile materials in NZK containers by using active neutron interrogation technique.

  12. Antifungal activity of Morinda citrifolia fruit extract against Candida albicans.

    PubMed

    Jainkittivong, Aree; Butsarakamruha, Tassanee; Langlais, Robert P

    2009-09-01

    The objective of the study was to investigate the antifungal activity of Morinda citrifolia fruit extract on Candida albicans. Juice extract from M. citrifolia fruit was lyophilized and used in antifungal testing. Antifungal activity of M. citrifolia fruit extract against C. albicans was tested in vitro at various concentrations and for different contact times. The inhibitory effect of M. citrifolia extract on C. albicans was determined by cultures and an applied broth dilution test. Using cultures, growth of C. albicans was not detected with 50 mg/mL of extract at 30-minute contact time or with 60 mg/mL of extract at 15-minute contact time. By the broth dilution test, the minimum fungicidal concentration of extract against C. albicans was 40 mg/mL at 90-minute contact time or with 50 mg/mL at 15-minute contact time. M. citrifolia fruit extract had an antifungal effect on C. albicans and the inhibitory effect varied with concentration and contact time.

  13. Differentiation of minute virus of mice and mouse parvovirus by high resolution melting curve analysis.

    PubMed

    Rao, Dan; Wu, Miaoli; Wang, Jing; Yuan, Wen; Zhu, Yujun; Cong, Feng; Xu, Fengjiao; Lian, Yuexiao; Huang, Bihong; Wu, Qiwen; Chen, Meili; Zhang, Yu; Huang, Ren; Guo, Pengju

    2017-12-01

    Murine parvovirus is one of the most prevalent infectious pathogens in mouse colonies. A specific primer pair targeting the VP2 gene of minute virus of mice (MVM) and mouse parvovirus (MPV) was utilized for high resolution melting (HRM) analysis. The resulting melting curves could distinguish these two virus strains and there was no detectable amplification of the other mouse pathogens which included rat parvovirus (KRV), ectromelia virus (ECT), mouse adenovirus (MAD), mouse cytomegalovirus (MCMV), polyoma virus (Poly), Helicobactor hepaticus (H. hepaticus) and Salmonella typhimurium (S. typhimurium). The detection limit of the standard was 10 copies/μL. This study showed that the PCR-HRM assay could be an alternative useful method with high specificity and sensitivity for differentiating murine parvovirus strains MVM and MPV. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. A model for the UHE gamma-rays from Hercules X-1

    NASA Technical Reports Server (NTRS)

    Eichler, D.; Vestrand, W. T.

    1985-01-01

    An outburst of gamma rays with energies E gamma 10 to the 12th power eV was recently detected from the X-ray pulsar Hercules X-1. The outburst had a 3 minute duration and occurred at a time during the 35 day X-ray modulation that is associated with X-ray turnon. The gamma rays also have the same 1.24 second modulation that is observed at X-ray energies. Subsequently a 40 minute outburst was detected at E gamma 10 to the 14th power eV. The interaction of ultrahigh energy particles with a precessing accretion disk explain the observed gamma ray light curve. The constraints one can place on acceleration mechanisms and the possibility that the UHE particles are accelerated by shocks in an accretion flow are explained.

  15. A comparison of septal stapler to suture closure in septoplasty: a prospective, randomized trial evaluating the effect on operative time.

    PubMed

    Sowerby, Leigh J; Wright, Erin D

    2013-11-01

    Septoplasty requires coaptation of the mucosal flaps at the conclusion of the procedure; classically this is done with nasal packing. Quilting sutures provide a welcome alternative to packing, but can be time-consuming to place. A septal stapler has recently been developed that provides a rapid alternative to quilting sutures but the timesaving has not been quantified. This study was a prospective, randomized trial comparing a septal stapler to quilting suture for coaptation of mucosal flaps in septoplasty. After meeting inclusion criteria, patients underwent septoplasty and inferior turbinoplasty. The total operative time, surgical segment times, including time for closure was recorded. Preoperative and postoperative Nasal Obstruction Symptom Evaluation (NOSE) scores were recorded. A sample size of 16 was determined to detect a difference of 5 minutes in closure time. A total of 16 patients were enrolled in the study. The mean time for closure with septal stapler was 35 ± 22 seconds vs 7 minutes ± 1 minute 10 seconds for suture closure (p < 0.0001). The mean total operative time using the septal stapler was 28 minutes ± 6 minutes whereas 43 minutes ± 13 minutes was required for suture (p = 0.014). No difference in postoperative complications or mucosal healing was seen; preoperative and postoperative improvement in NOSE scores was comparable. Coaptation of the mucosal flaps in septoplasty with a septal stapler affords a timesaving in the operating room with no difference in operative outcome. © 2013 ARS-AAOA, LLC.

  16. Habitat relationships of landbirds in the Northern Region, USDA Forest Service

    Treesearch

    Richard L. Hutto; Jock S. Young

    1999-01-01

    A series of first-generation habitat-relationships models for 83 bird species were detected in a 3-year study on point counts conducted in association with the USDA Forest Service's Northern Region Landbird Monitoring Program. The models depict probabilities of detection for each of the bird species on 100-m-radius, 10-minute point counts conducted across a series...

  17. Breast Cancer Detection

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The BioScan System was developed by OmniCorder Technologies, Inc. at the Jet Propulsion Laboratory. The system is able to locate cancerous lesions by detecting the cancer's ability to recruit a new blood supply. A digital sensor detects infrared energy emitted from the body and identifies the minute differences accompanying the blood flow changes associated with cancerous cells. It also has potential use as a monitoring device during cancer treatment. This technology will reduce the time taken to detect cancerous cells and allow for earlier intervention, therefore increasing the overall survival rates of breast cancer patients.

  18. The effect of laminar air flow and door openings on operating room contamination.

    PubMed

    Smith, Eric B; Raphael, Ibrahim J; Maltenfort, Mitchell G; Honsawek, Sittisak; Dolan, Kyle; Younkins, Elizabeth A

    2013-10-01

    We evaluate the association of laminar airflow (LAF) and OR traffic with intraoperative contamination rates. Two sterile basins were placed in each room during 81 cases, one inside and one outside the LAF. One Replicate Organism Detection and Counting (RODAC) plate from each basin was sent for culture at successive 30-minute intervals from incision time until wound closure. At successive 30-minute intervals more plates were contaminated outside than inside the LAF. A negative binomial model showed that the bacteria colony forming units (CFU) depended on whether there were any door openings (P=0.02) and the presence of LAF (P=0.003). LAF decreases CFU by 36.6%. LAF independently reduces the risk of contamination and microbial counts for surgeries lasting 90 minutes or less. © 2013.

  19. Hydrocyclone/Filter for Concentrating Biomarkers from Soil

    NASA Technical Reports Server (NTRS)

    Ponce, Adrian; Obenhuber, Donald

    2008-01-01

    The hydrocyclone-filtration extractor (HFE), now undergoing development, is a simple, robust apparatus for processing large amounts of soil to extract trace amounts of microorganisms, soluble organic compounds, and other biomarkers from soil and to concentrate the extracts in amounts sufficient to enable such traditional assays as cell culturing, deoxyribonucleic acid (DNA) analysis, and isotope analysis. Originally intended for incorporation into a suite of instruments for detecting signs of life on Mars, the HFE could also be used on Earth for similar purposes, including detecting trace amounts of biomarkers or chemical wastes in soils.

  20. North American coral snake antivenin for the neutralization of non-native elapid venoms in a murine model.

    PubMed

    Richardson, William H; Tanen, David A; Tong, Tri C; Betten, David P; Carstairs, Shaun D; Williams, Saralyn R; Cantrell, Frank L; Clark, Richard F

    2006-02-01

    North American coral snake antivenin (CSAV; Wyeth Antivenin [Micrurus fulvius], equine origin) is approved for the treatment of coral snake envenomations in the United States. The coral snake is the only elapid that is native to North America, but envenomations from non-native elapids are occurring more commonly in this country. This study was designed to evaluate the efficacy of CSAV in the neutralization of two exotic elapid envenomations: Naja naja (Indian cobra) and Dendroaspis polylepsis (black mamba). A randomized, blinded, placebo-controlled murine model of intraperitoneal venom injection was employed. Venom potency was determined in preliminary dosing studies. Study animals then were divided into five groups: 1) N. naja venom + CSAV, 2) N. naja venom + 0.9% normal saline (NS), 3) D. polylepsis venom + CSAV, 4) D. polylepsis venom + NS, and 5) CSAV + NS. The venom dose was chosen to be twice the estimated LD50. The amount of CSAV injected was ten times the amount necessary for neutralization of a 2 x LD50 dose of M. f. fulvius venom in a murine model. Statistical analysis included Fisher's exact and log-rank testing to compare survival rates and times. Preliminary studies estimated the venom LD50 to be 2.58 mg/kg and 0.45 mg/kg, respectively, for the N. naja and D. polylepsis. A significant difference was shown in comparison of survival times between CSAV-venom groups and normal saline-venom groups despite all animals in both treatment and control arms dying. Animals receiving CSAV and N. naja venom survived (mean +/- SD) 24.4 +/- 3.0 minutes, versus 17.8 +/- 1.3 minutes in the control group (p < 0.001), whereas those receiving CSAV and D. polylepsis venom survived 203.8 +/- 37.0 minutes versus 130.0 +/- 42.6 minutes in the control group (p < 0.001). All animals in the CSAV + NS group survived to the conclusion of the study. When premixed with venom, CSAV increased survival time in a murine model of intraperitoneal N. naja and D. polylepsis venom injection. The clinical implications of this are unclear, given unchanged mortality rates.

  1. Nicotine delivery efficiency of first- and second-generation e-cigarettes and its impact on relief of craving during the acute phase of use.

    PubMed

    Rüther, Tobias; Hagedorn, Dieter; Schiela, Konstantin; Schettgen, Thomas; Osiander-Fuchs, Helga; Schober, Wolfgang

    2018-03-01

    Knowledge about the change in blood nicotine concentrations during the first five minutes (acute phase) of e-cigarette vaping is important to determine whether the used product has a dependence potential or may be an efficient nicotine replacement product. To address this issue, we monitored blood nicotine levels during the acute phase in volunteers using disposable cigalikes (CLs) and a tank model (TM) and compared them with blood nicotine levels in subjects using a tobacco cigarette (TC). In parallel, heart rate changes were continually measured and withdrawal symptoms and craving were assessed with the Questionnaire on Smoking Urges before and immediately after the vaping/smoking sessions. Additionally, at the end of each session negative health effects were rated on a visual analog scale. After five minutes of e-cigarette or TC use, the mean nicotine plasma concentrations were as follows: CLs, 5.5ng/ml; TM, 9.3ng/ml; TC, 17.1ng/ml. Nicotine levels increased significantly faster in the first 4min of consuming a TC than with the CLs and the TM. The highest rate of increase in nicotine concentration was found with the TC (6.8ng/ml) and TM (2.3ng/ml) between the 1st and 2nd minute, whereas the CLs showed comparatively small changes in the amount delivered over the five minutes. Withdrawal and craving for smoking decreased with the TM by the same amount as with the TC, even though less nicotine was delivered to the blood and considerably fewer side effects occurred. The heart rate of TM users was also markedly lower than that of the TC users. Unlike CLs, TM e-cigarettes represent an effective source of nicotine and might be used as an alternative nicotine replacement product to aid smoking cessation. However, nicotine plasma levels observed in TM users after short-time vaping have also the potential to produce and sustain nicotine addiction. Copyright © 2017 Elsevier GmbH. All rights reserved.

  2. Chemical matricectomy with sodium hydroxide: long-term follow-up results.

    PubMed

    Bostanci, Seher; Kocyigit, Pelin; Parlak, Nehir; Gungor, Hilayda Karakok

    2014-11-01

    Chemical matricectomy with sodium hydroxide is a method being used successfully in the treatment of ingrown toenail. In this study, it was aimed to evaluate long-term recurrence rates after chemical matricectomy using sodium hydroxide application of different durations. Two hundred two patients with ingrown nail edges were treated with either 1-minute (Group 1) or 2-minute (Group 2) applications of sodium hydroxide matricectomy. All patients were followed for at least 2 years. Chemical matricectomy with sodium hydroxide was applied to a total of 585 nail edges of 202 cases. The overall recurrence rates in Group 1 and Group 2 were 6.4% and 7.1%, respectively, during the average 7.5-year follow-up period. No statistically significant differences were detected in terms of recurrence between the 2 groups (p = .73). Chemical matricectomy with sodium hydroxide is an easy method in the treatment of ingrown nails, with low morbidity and high success rates. There was no difference between 1-minute and 2-minute applications in terms of recurrence during the long-term follow-up. Chemical matricectomy with 1-minute application of sodium hydroxide showed high success in terms of long-term follow-up results.

  3. Effect of sub-Tenon's and peribulbar anesthesia on intraocular pressure and ocular pulse amplitude.

    PubMed

    Pianka, P; Weintraub-Padova, H; Lazar, M; Geyer, O

    2001-08-01

    To compare the effect of peribulbar and sub-Tenon's anesthesia on intraocular pressure (IOP) and ocular pulse amplitude (OPA) in the injected eye and the fellow noninjected (control) eye. Tel Aviv Medical Center, Tel Aviv, Israel. This prospective study measured IOP and OPA at baseline and 1 and 10 minutes after administration of lidocaine anesthesia in 40 consecutive adult patients having elective cataract surgery. The IOP remained stable throughout the study with both modes of anesthesia. One minute after injection of the anesthetic agent, the OPA was significantly decreased in the injected eyes in both the sub-Tenon's (24%; P < .05) and peribulbar (25%; P < .05) groups. The decrease in the OPA in the sub-Tenon's group (14%; P < .05) was detectable after 10 minutes in the control eyes. In the peribulbar anesthesia group, the OPA in the control eyes increased significantly (9%; P < .05) 1 minute after injection of the anesthetic agent, returning to preinjection levels 10 minutes after the injection. The OPA in the eyes in which lidocaine was injected decreased significantly in both the sub-Tenon's and peribulbar groups. These findings have implications for the management of patients whose ocular circulation may be compromised.

  4. Root canal preparation with a novel nickel-titanium instrument evaluated with micro-computed tomography: canal surface preparation over time.

    PubMed

    Peters, Ove A; Boessler, Claudia; Paqué, Frank

    2010-06-01

    The aim of this part of an ongoing study was to describe the dentin removal ability of a novel nickel-titanium instrument, the self-adjusting file (SAF), by using micro-computed tomography. Twenty maxillary incisors were scanned preoperatively at 20-microm resolution and postoperatively after up to 6 minutes of preparation with an SAF with 1.5-mm or 2-mm diameter. SAFs were operated with continuous irrigation in a handpiece that provided an oscillating, in-and-out movement. Changes in canal volume compared with preoperative values as well as unprepared canal surface area were determined. Data were normally distributed and compared by analysis of variance and regression analyses. Preoperatively canal volumes were statistically similar in both groups (9.86 +/- 3.97 mm3 and 9.80 +/- 2.67 mm3). Volumes increased during preparation to 13.58 +/- 3.85 mm3 (after 6 minutes with SAF 1.5 mm) and 16.43 +/- 3.64 mm3 (after 5 minutes with SAF 2.0 mm), and overall canal shapes were adequate. Unprepared canal surface area decreased from 63.0% +/- 15.1% (2 minutes with SAF 1.5 mm) to 8.6% +/- 4.1% (5 minutes with SAF 2.0 mm). Preparation of straight root canals in maxillary anterior teeth left little canal surface uninstrumented after shaping with the SAF. The timeframe of clinical application will depend on the amount of desired dentin removal and done with an SAF selected on the basis of apical gauging. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Adaptability to pain is associated with potency of local pain inhibition, but not conditioned pain modulation: a healthy human study.

    PubMed

    Zheng, Zhen; Wang, Kelun; Yao, Dongyuan; Xue, Charlie C L; Arendt-Nielsen, Lars

    2014-05-01

    This study investigated the relationship between pain sensitivity, adaptability, and potency of endogenous pain inhibition, including conditioned pain modulation (CPM) and local pain inhibition. Forty-one healthy volunteers (20 male, 21 female) received conditioning stimulation (CS) over 2 sessions in a random order: tonic heat pain (46 °C) on the right leg for 7 minutes and cold pressor pain (1 °C to 4 °C) on the left hand for 5 minutes. Participants rated the intensity of pain continuously using a 0 to 10 electronic visual analogue scale. The primary outcome measures were pressure pain thresholds (PPT) measured at the heterotopic and homotopic location to the CS sites before, during, and 20 minutes after CS. Two groups of participants, pain adaptive and pain nonadaptive, were identified based on their response to pain in the cold pressor test. Pain-adaptive participants showed a pain reduction between peak pain and pain at end of the test by at least 2 of 10 (n=16); whereas the pain-nonadaptive participants reported unchanged peak pain during 5-minute CS (n=25). Heterotopic PPTs during the CS did not differ between the 2 groups. However, increased homotopic PPTs measured 20 minutes after CS correlated with the amount of pain reduction during CS. These results suggest that individual sensitivity and adaptability to pain does not correlate with the potency of CPM. Adaptability to pain is associated with longer-lasting local pain inhibition. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  6. Dust Emissions from Undisturbed and Disturbed, Crusted Playa Surfaces: Cattle Trampling Effect

    NASA Astrophysics Data System (ADS)

    Zobeck, T. M.; Baddock, M. C.; van Pelt, R.; Fredrickson, E. L.

    2009-12-01

    Dry playa lake beds can be a significant source of fine dust emissions during high wind events in arid and semiarid landscapes. The physical and chemical properties of the playa surface control the amount and properties of the dust emitted. In this study, we use a field wind tunnel to quantify the dust emissions from a bare, fine-textured playa surface located in the Chihuahua Desert at the Jornada Experimental Range, near Las Cruces, New Mexico, USA. We tested natural, undisturbed crusted surfaces and surfaces that had been subjected to two levels of domestic animal disturbance. The animal disturbance was provided by trampling produced from one and ten passes along the length of the wind tunnel by a 630 kg Angus-Hereford cross cow. The trampling broke the durable crust and created loose erodible material. Each treatment (natural crust, one pass, and ten passes) was replicated three times. A push-type wind tunnel with a 6 m long, 0.5 m wide, and 1 m high test section was used to generate dust emissions under controlled conditions. Clean medium sand was dropped onto the playa surface to act as an abrader material. The tunnel wind speed was equivalent to 15 m/s at a height of 2 m over a smooth soil surface. The tunnel was initially run for ten minutes, with no abrader added. A second 30 minute run was subsequently sampled as abrader was added to the wind stream. Dust and saltating material were collected using an isokinetic slot sampler at the end of the tunnel. Total airborne dust was collected on two 25 cm x 20 cm glass fiber filters (GFF) and measured using a GRIMM particle monitor every 6 sec throughout each test run. Disturbance by trampling generated increased saltating material and airborne dust. The amount of saltating material measured during the initial (no abrader added) run was approximately 70% greater and 5.8 times the amount of saltating material measured on the one pass and ten pass plots, respectively, compared with that observed on the undisturbed plots. The total amount of dust measured during the initial (no abrader added) run on GFF for the one pass and ten pass plots was almost twice and three times, respectively, that observed on the undisturbed plots. The ten pass treatment generated about 75% more PM10 dust, as measured by the GRIMM particle monitor, than the undisturbed plots during the 30 minute abrader run.

  7. Computer-aided detection of colorectal polyps: can it improve sensitivity of less-experienced readers? Preliminary findings.

    PubMed

    Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael

    2007-10-01

    To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.

  8. METHOD OF TESTING FOR LEAKS

    DOEpatents

    Creutz, E.C.; McAdams, Wm.A.; Foss, M.H.

    1958-07-22

    A method is described for detecting minute holes In fuel element jackets. The method comprises submerging the jacketed body in an atmosphere of a radioactive gas under pressure, the radioactive emanations from said gas being sufficientiy penetratIng to penetrate the jacket of the jacketed body. After the jacketed body is removed from the radtoactive gas atmosphere, it is exannined for the presence of emanations from radioactive gas which entered the jacketed body through the minute holes. In this manner, the detectton of radioactive emanations is a positive indication that the fuel element is not perfectly sealed.

  9. Capillary electrophoresis-MALDI interface based on inkjet technology

    PubMed Central

    Vannatta, Michael W.; Whitmore, Colin D.; Dovichi, Norman J.

    2010-01-01

    An ink jet printer valve and nozzle were used to deliver matrix and sample from an electrophoresis capillary onto a MALDI plate. The system was evaluated by separation of a set of standard peptides. That separation generated up to 40,000 theoretical plates in less than three minutes. Detection limits were 500 amol using an ABI TOF-TOF instrument and 2 fmol for an ABI Q-TOF instrument. Over 70% coverage was obtained for the tryptic digest of α-lactalbumin in less than 2.5 minutes. PMID:19960472

  10. Television Viewing by Young Secondary Students: A Study of the Television Viewing Behavior of Children at Form Two Level.

    ERIC Educational Resources Information Center

    Powell, R. J.

    Television viewing habits of 12 to 14 year olds in Australia were studied, and an attempt was made to correlate amount of viewing time and choice of programs with these children's intelligence and personality. Average viewing time per night was three hours and 40 minutes. A large variation was found in the time at which children ceased viewing.…

  11. Relative age effect and left-handedness in world class water polo male and female players.

    PubMed

    Barrenetxea-Garcia, Josu; Torres-Unda, Jon; Esain, Izaro; Gil, Susana M

    2018-06-01

    Most studies of the relative age effect (RAE) refer to popular sports. In contrast, we examined to what extent the RAE is present in elite water polo players, as well as the association between handedness and RAE. For these purposes, laterality, anthropometry, month of birth, performance and playing position of participants in the 2011, 2013 and 2015 World Championships (623 women, 622 men) were analised. No RAE was observed in the total sample. However, the proportion of male left-handed field players born in the first quarter (11%) was lower than those born in the second (35.3%) and fourth quarter (29.4%). Regarding the overall laterality, the amount of left handed players was similar to the general population (10%). Nevertheless, there was a larger amount of left-handed wings than expected both in men (23.7%) and women (34.4%). Left-handed male players performed more shots, shots/minute and also scored more goals than right-handed players. Women left-handed players were younger and they performed more shots/minute. There is no RAE in elite male and female water polo players. However, laterality could be a possible moderator of the RAE particularly in left handed players, which should be taken into account in future studies.

  12. The effect of objectively measured crime on walking in minority adults.

    PubMed

    McDonald, Noreen C

    2008-01-01

    Evaluate the relationship between neighborhood crime and the amount of daily walking by minority adults. This was a cross-sectional study of minority adult walking behavior and crime. Setting. Oakland, California was chosen as the study area because of the substantial spatial variation in levels of criminal activity combined with detailed information on walking trips. The study was restricted to minority adults who responded to the 2000 Bay Area Travel Survey and lived in Oakland, California (n = 359). Data on leisure and utilitarian walking were collected through the 2000 Bay Area Travel Survey and combined with crime data from the Oakland Police Department. A negative binomial model was used to test if violent, property, or quality of life crimes had significant associations with daily minutes walked, controlling for individual and neighborhood covariates. The model showed a significant negative association between violent crime and minutes walked per day (b = -.07; p = .016). Neither property nor quality of life crimes were correlated with amount of walking. Reductions in violent crime may increase opportunities for minority residents in urban areas to participate in physical activity such as walking, thereby providing another reason to pursue anticrime measures. Urban designers' efforts to increase physical activity by improving neighborhood walkability may consider violent crime prevention in their designs.

  13. Physical activity guidelines for older adults.

    PubMed

    Elsawy, Bassem; Higgins, Kim E

    2010-01-01

    Few older adults in the United States achieve the minimum recommended amount of physical activity. Lack of physical activity contributes to many chronic diseases that occur in older adults, including heart disease, stroke, diabetes mellitus, lung disease, Alzheimer disease, hypertension, and cancer. Lack of physical activity, combined with poor dietary habits, has also contributed to increased obesity in older persons. Regular exercise and increased aerobic fitness are associated with a decrease in all-cause mortality and morbidity, and are proven to reduce disease and disability, and improve quality of life in older persons. In 2008, The U.S. Department of Health and Human Services released guidelines to provide information and guidance on the amount of physical activity recommended to maintain health and fitness. For substantial health benefits, the guidelines recommend that most older adults participate in at least 150 minutes of moderate-intensity aerobic activity, 75 minutes of vigorous-intensity aerobic activity, or an equivalent combination of each per week. Older adults should also engage in strengthening activities that involve all major muscle groups at least two days a week. Those at risk of falling should add exercises that help maintain or improve balance. Generally healthy adults without chronic health conditions do not need to consult with a physician before starting an exercise regimen. (c) 2010 American Academy of Family Physicians.

  14. An investigation of the association between socio-demographic factors, dog-exercise requirements, and the amount of walking dogs receive.

    PubMed

    Degeling, Chris; Burton, Lindsay; McCormack, Gavin R

    2012-07-01

    Risk factors associated with canine obesity include the amount of walking a dog receives. The aim of this study was to investigate the relationships between canine exercise requirements, socio-demographic factors, and dog-walking behaviors in winter in Calgary. Dog owners, from a cross-sectional study which included a random sample of adults, were asked their household income, domicile type, gender, age, education level, number and breed(s) of dog(s) owned, and frequency and time spent dog-walking in a usual week. Canine exercise requirements were found to be significantly (P < 0.05) positively associated with the minutes pet dogs were walked, as was the owner being a female. Moreover, dog walking frequency, but not minutes of dog walking, was significantly associated with residing in attached housing (i.e., apartments). Different types of dogs have different exercise requirements to maintain optimal health. Understanding the role of socio-demographic factors and dog-related characteristics such as exercise requirements on dog-walking behaviors is essential for helping veterinarians and owners develop effective strategies to prevent and manage canine obesity. Furthermore, encouraging regular dog-walking has the potential to improve the health of pet dogs, and that of their owners.

  15. Hyperventilation during routine electroencephalography: are three minutes really necessary?

    PubMed

    Watemberg, Nathan; Farkash, Michael; Har-Gil, Miki; Sezer, Taner; Goldberg-Stern, Hadassah; Alehan, Füsun

    2015-04-01

    Hyperventilation induces absence seizures in children with absence epilepsy, and routine electroencephalography studies include three minutes of hyperventilation. We studied the duration of hyperventilation required to provoke a first absence seizure to determine whether three minutes of the procedure are indeed necessary. Electroencephalography records of children who experienced absence seizures during hyperventilation were reviewed. The time from hyperventilation onset to a first and further seizure(s) was measured, and the occurrence of absences during the posthyperventilation phase was also noted. Sixty-two studies were evaluated. Mean time from hyperventilation onset to a first absence was 52 seconds (median 32 seconds). The vast majority (85.5%) had an absence within 90 seconds. Most (68%) children sustained a single event. All eight children with posthyperventilation seizures had experienced at least one event during hyperventilation. Our findings suggest that current guidelines for routine pediatric electroencephalography recording requiring three minutes of hyperventilation may not be clinically necessary. We found that the vast majority of children referred for suspected absence seizures experience a seizure less than 90 seconds after hyperventilation onset, and even more so by 120 seconds. Hence, a larger prospective study is warranted to establish more accurate hyperventilation duration parameters. We also suggest that once an absence seizure has been recorded at any time during hyperventilation, this procedure could be stopped, thus reducing the amount of discomfort for the child. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Tectonic Tremor analysis with the Taiwan Chelungpu-Fault Drilling Program (TCDP) downhole seismometer array

    NASA Astrophysics Data System (ADS)

    Lin, Y.; Hillers, G.; Ma, K.; Campillo, M.

    2011-12-01

    We study tectonic tremor activity in the Taichung area, Taiwan, analyzing continuous seismic records from 6 short-period sensors of the TCDP borehole array situated around 1 km depth. The low background noise level facilitates the detection of low-amplitude tectonic tremor and low-frequency earthquake (LFE) waveforms. We apply a hierarchical analysis to first detect transient amplitude increases, and to subsequently verify its tectonic origin, i.e. to associate it with tremor signals. The frequency content of tremor usually exceeds the background noise around 2-8 Hz; hence, in the first step, we use BHS1, BHS4 and BHS7 (top, center, bottom sensor) records to detect amplitude anomalies in this frequency range. We calculate the smoothed spectra of 30 second non-overlapping windows taken daily from 5 night time hours to avoid increased day time amplitudes associated with cultural activities. Amplitude detection is then performed on frequency dependent median values of 5 minute advancing, 10 minute long time windows, yielding a series of threshold dependent increased-energy spectra-envelopes, indicating teleseismic waveforms, potential tremor records, or other transients related to anthropogenic or natural sources. To verify the transients' tectonic origin, potential tremor waveforms detected by the amplitude method are manually picked in the time domain. We apply the Brown et al. (2008) LFE matched filter technique to three-component data from the 6 available sensors. Initial few-second templates are taken from the analyst-picked, minute-long segments, and correlated component-wise with 24-h data. Significantly increased similarity between templates and matched waveform segments is detected using the array-average 7-fold MAD measure. Harvested waveforms associated with this initial `weak' detection are stacked, and the thus created master templates are used in an iterative correlation procedure to arrive at robust LFE detections. The increased similarity of waveforms, showing essentially no moveout across the array, suggests a common source and path effect, therefore increasing the likelihood of a tectonic origin. Preliminary results from a pilot analysis confirm the existence of tremor-like signals in the tremor-typical frequency range. We present results from a comprehensive analysis of at least 2 years of continuous data. A limited resolution location procedure is applied, testament to the receiver geometry, and the inferred locations are discussed in relation to the tectonic situation.

  17. Mechanisms and time course of menthol-induced cutaneous vasodilation

    PubMed Central

    Craighead, Daniel H.; McCartney, Nathaniel B.; Tumlinson, James H.; Alexander, Lacy M.

    2017-01-01

    Menthol is a vasoactive compound that is widely used in topical analgesic agents. Menthol induces cutaneous vasodilation, however the underlying mechanisms are unknown. Determining the rates of appearance and clearance of menthol in the skin is important for optimizing topical treatment formulation and dosing. The purpose of this study was to determine the mechanisms contributing to menthol-mediated cutaneous vasodilation and to establish a time course for menthol appearance/clearance in the skin. Ten young (23±1 years, 5 males 5 females) subjects participated in two protocols. In study 1, four intradermal microdialysis fibers were perfused with increasing doses of menthol (0.1-500mM) and inhibitors for nitric oxide (NO), endothelium derived hyperpolarizing factors (EDHFs), and sensory nerves. Skin blood flow was measured with laser Doppler flowmetry and normalized to %CVCmax. In study 2, two intradermal microdialysis fibers were perfused with lactated Ringer's solution. 0.017mL•cm-2 of a 4% menthol gel was placed over each fiber. 5μL samples of dialysate from the microdialysis fibers were collected every 30 minutes and analyzed for the presence of menthol with high performance gas chromatography/mass spectrometry. Skin blood flow (laser speckle contrast imaging) and subjective ratings of menthol sensation were simultaneously obtained with dialysate samples. In study 1, menthol induced cutaneous vasodilation at all doses ≥100mM (all p<0.05). However, inhibition of either NO, EDHFs, or sensory nerves fully inhibited menthol-mediated vasodilation (all p>0.05). In study 2, significant menthol was detected in dialysate 30 minutes post menthol application (0.89ng, p=0.0002). Relative to baseline, cutaneous vasodilation was elevated from minutes 15-45 and ratings of menthol sensation were elevated from minute 5-60 post menthol application (all p<0.05). Menthol induces cutaneous vasodilation in the skin through multiple vasodilator pathways, including NO, EDHF, and sensory nerves. Topical menthol is detectable in the skin within 30 minutes and is cleared by 60 minutes. Skin blood flow and perceptual measures follow a similar time course as menthol appearance/clearance. PMID:27899298

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milligan, Ryan O.; Fletcher, Lyndsay; Fleck, Bernhard

    In this Letter we report the detection of chromospheric 3-minute oscillations in disk-integrated EUV irradiance observations during a solar flare. A wavelet analysis of detrended Ly α (from GOES /EUVS) and Lyman continuum (from Solar Dynamics Observatory ( SDO )/EVE) emission from the 2011 February 15 X-class flare (SOL2011-02-15T01:56) revealed a ∼3 minute period present during the flare’s main phase. The formation temperature of this emission locates this radiation at the flare’s chromospheric footpoints, and similar behavior is found in the SDO /Atmospheric Imaging Assembly 1600 and 1700 Å channels, which are dominated by chromospheric continuum. The implication is thatmore » the chromosphere responds dynamically at its acoustic cutoff frequency to an impulsive injection of energy. Since the 3-minute period was not found at hard X-ray (HXR) energies (50–100 keV) in Reuven Ramaty High Energy Solar Spectroscopic Imager data we can state that this 3-minute oscillation does not depend on the rate of energization of non-thermal electrons. However, a second period of 120 s found in both HXR and chromospheric lightcurves is consistent with episodic electron energization on 2-minute timescales. Our finding on the 3-minute oscillation suggests that chromospheric mechanical energy should be included in the flare energy budget, and the fluctuations in the Ly α line may influence the composition and dynamics of planetary atmospheres during periods of high activity.« less

  19. Portable Biomarker Detection with Magnetic Nanotags

    PubMed Central

    Hall, Drew A.; Wang, Shan X.; Murmann, Boris; Gaster, Richard S.

    2012-01-01

    This paper presents a hand-held, portable biosensor platform for quantitative biomarker measurement. By combining magnetic nanoparticle (MNP) tags with giant magnetoresistive (GMR) spin-valve sensors, the hand-held platform achieves highly sensitive (picomolar) and specific biomarker detection in less than 20 minutes. The rapid analysis and potential low cost make this technology ideal for point-of-care (POC) diagnostics. Furthermore, this platform is able to detect multiple biomarkers simultaneously in a single assay, creating a promising diagnostic tool for a vast number of applications. PMID:22495252

  20. Oscillations in a Sunspot with Light Bridges

    NASA Astrophysics Data System (ADS)

    Yuan, Ding; Nakariakov, Valery M.; Huang, Zhenghua; Li, Bo; Su, Jiangtao; Yan, Yihua; Tan, Baolin

    2014-09-01

    The Solar Optical Telescope on board Hinode observed a sunspot (AR 11836) with two light bridges (LBs) on 2013 August 31. We analyzed a two-hour Ca II H emission intensity data set and detected strong five-minute oscillation power on both LBs and in the inner penumbra. The time-distance plot reveals that the five-minute oscillation phase does not vary significantly along the thin bridge, indicating that the oscillations are likely to originate from underneath it. The slit taken along the central axis of the wide LB exhibits a standing wave feature. However, at the center of the wide bridge, the five-minute oscillation power is found to be stronger than at its sides. Moreover, the time-distance plot across the wide bridge exhibits a herringbone pattern that indicates a counter-stream of two running waves, which originated at the bridge's sides. Thus, the five-minute oscillations on the wide bridge also resemble the properties of running penumbral waves. The five-minute oscillations are suppressed in the umbra, while the three-minute oscillations occupy all three cores of the sunspot's umbra, separated by the LBs. The three-minute oscillations were found to be in phase at both sides of the LBs. This may indicate that either LBs do not affect umbral oscillations, or that umbral oscillations at different umbral cores share the same source. It also indicates that LBs are rather shallow objects situated in the upper part of the umbra. We found that umbral flashes (UFs) follow the life cycles of umbral oscillations with much larger amplitudes. They cannot propagate across LBs. UFs dominate the three-minute oscillation power within each core; however, they do not disrupt the phase of umbral oscillation.

  1. Choline and Inositol Distribution in Algae and Fungi1

    PubMed Central

    Ikawa, Miyoshi; Borowski, Paul T.; Chakravarti, Ashima

    1968-01-01

    Inositol and choline were present in varying amounts among the species of Rhodophyta, Phaeophyta, Chlorophyta, and Euglenophyta examined. However, in the two members of the order Fucales (division Phaeophyta) examined, no detectable amounts of choline were found. In contrast, the species of Cyanophyta examined contained no detectable amounts of either choline or inositol. All species of the fungal classes Phycomyceteae, Ascomyceteae, and Basidiomyceteae collected contained both inositol and choline in varying amounts. The red, brown, and blue-green algae usually contained much less inositol and choline than do plant and animals sources, but the fungi and the algae Chlorella and Euglena contained amounts comparable to those present in plant sources. PMID:5647522

  2. [Application of Vojta's method for early detection of developmental disturbances in very low birthweight infants with regard to Apgar score and asymmetric body positions].

    PubMed

    Gajewska, Ewa; Samborski, Włodzimierz

    2006-01-01

    This work focuses on the usefulness of assessment based on seven body positions according to Vojta for early detection of developmental abnormalities of the central nervous system. As additional factors, Apgar score at 1st and 5th minute of life, as well as asymmetry of head or of whole body at the time of investigation (usually third month of life) were analyzed in correlation with subsequent diagnosis of cerebral palsy usually established after the first year of life. The study group consisted of 57 children with birthweight lower than 1500 grams. Seven children were diagnosed with cerebral palsy at the age of one year. The following conclusions were drawn: Vojta's diagnostic method is very sensitive in detecting injury of the central nervous system early in life; high correlation was found between cerebral palsy and asymmetry of the body, but not of the head; low Apgar score at 5th but not at 1st minute is highly predictive for progression to cerebral palsy in infants with very low birthweight.

  3. Rapid Microcystin Determination Using a Paper Spray Ionization Method with a Time-of-Flight Mass Spectrometry System.

    PubMed

    Zhu, Xiaoqiang; Huang, Zhengxu; Gao, Wei; Li, Xue; Li, Lei; Zhu, Hui; Mo, Ting; Huang, Bao; Zhou, Zhen

    2016-07-13

    The eutrophication of surface water sources and climate changes have resulted in an annual explosion of cyanobacterial blooms in many irrigating and drinking water resources. To decrease health risks to the public, a rapid real time method for the synchronous determination of two usually harmful microcystins (MC-RR and MC-LR) in environmental water samples was built by employing a paper spray ionization method coupled with a time-of-flight mass spectrometer system. With this approach, direct analysis of microcystin mixtures without sample preparation has been achieved. Rapid detection was performed, simulating the release process of microcystins in reservoir water samples, and the routine detection frequency was every three minutes. The identification time of microcystins was reduced from several hours to a few minutes. The limit of detection is 1 μg/L, and the limit of quantitation is 3 μg/L. This method displays the ability for carrying out rapid, direct, and high-throughput experiments for determination of microcystins, and it would be of significant interest for environmental and food safety applications.

  4. Metabolic perturbations in Welsh Ponies with insulin dysregulation, obesity, and laminitis

    PubMed Central

    Murray, Kevin J.; Rendahl, Aaron K.; Geor, Raymond J.; Schultz, Nichol E.; McCue, Molly E.

    2018-01-01

    Background Metabolomics, the study of small‐molecule metabolites, has increased understanding of human metabolic diseases, but has not been used to study equine metabolic syndrome (EMS). Objectives (1) To examine the serum metabolome of Welsh Ponies with and without insulin dysregulation before and during an oral sugar test (OST). (2) To identify differences in metabolites in ponies with insulin dysregulation, obesity, or history of laminitis. Animals Twenty Welsh Ponies (mean ± SD; 13.8 ± 9.0 years) classified as non‐insulin dysregulated [CON] (n = 10, insulin < 30 mU/L) or insulin dysregulated [ID] (n = 10, insulin > 60 mU/L) at 75 minutes after administration of Karo syrup, obese (n = 6) or nonobese (n = 14), and history of laminitis (n = 9) or no history of laminitis (n = 11). Methods Case‐control study. Metabolomic analysis was performed on serum obtained at 0 minutes (baseline) and 75 minutes during the OST. Data were analyzed with multivariable mixed linear models with significance set at P ≤ .05. Results Metabolomic analysis of 646 metabolites (506 known) detected significant metabolite differences. At baseline, 55 metabolites (insulin response), 91 metabolites (obesity status), and 136 metabolites (laminitis history) were different. At 75 minutes, 51 metabolites (insulin response), 102 metabolites (obesity status), and 124 metabolites (laminitis history) were different. Conclusions and Clinical Importance Use of metabolomics could have diagnostic utility for early detection of EMS and provide new knowledge regarding the pathophysiology of metabolic perturbations associated with this condition that might lead to improved clinical management. PMID:29572947

  5. Evaluation of 68Ga-labeled peptide tracer for detection of gelatinase expression after myocardial infarction in rat.

    PubMed

    Kiugel, Max; Kytö, Ville; Saanijoki, Tiina; Liljenbäck, Heidi; Metsälä, Olli; Ståhle, Mia; Tuomela, Johanna; Li, Xiang-Guo; Saukko, Pekka; Knuuti, Juhani; Roivainen, Anne; Saraste, Antti

    2016-12-02

    Matrix metalloproteinases 2 and 9 (MMP-2/9) play a role in extracellular matrix remodeling after an ischemic myocardial injury. We evaluated 68 Ga-DOTA-peptide targeting MMP-2/9 for the detection of gelatinase expression after myocardial infarction (MI) in rat. Rats were injected with 43 ± 7.7 MBq of 68 Ga-DOTA-peptide targeting MMP-2/9 at 7 days (n = 7) or 4 weeks (n = 8) after permanent coronary ligation or sham operation (n = 5 at both time points) followed by positron emission tomography (PET). The left ventricle was cut in frozen sections for autoradiography and immunohistochemistry 30 minutes after tracer injection. Immunohistochemical staining showed MMP-2 and MMP-9 expressing cells, CD31-positive endothelial cells, and CD68-positive macrophages in the infarcted myocardium. Autoradiography showed increased tracer uptake in the infarcted area both at 7 days and 4 weeks after MI (MI-to-remote area ratio 2.5 ± 0.46 and 3.1 ± 1.0, respectively). Tracer uptake in damaged tissue correlated with the amount of CD68-positive macrophages at 7 days after MI, and CD31-positive endothelial cells at 7 days and 4 weeks after MI. The tracer was rapidly metabolized, radioactivity in the blood exceeded that of the myocardium, and tracer accumulation in the heart was not detectable by in vivo PET. 68 Ga-DOTA-peptide targeting MMP-2/9 accumulates in the damaged rat myocardium after an ischemic injury, but tracer instability and slow clearance in vivo make it unsuitable for further evaluation.

  6. Measurement of fumonisins in corn with a fiber optic fluoroimmunosensor

    NASA Astrophysics Data System (ADS)

    Thompson, Vicki S.; Maragos, Chris M.

    1997-05-01

    A fiber-optic immunosensor was used to determine concentrations of the mycotoxin fumonisin B1(FB1) in both spiked and naturally contaminated corn samples. Samples were extracted with a mixture of methanol/water. Two methods were used to prepare the methanolic corn extracts before introduction to the immunosensor: (1) simple dilution of the methanolic corn extract; or (2) affinity column cleanup. The sensor displayed an IC50 of 70 ng FB1/mL when toxin was introduced in phosphate buffered saline. Simple dilution of methanolic corn extracts yielded an assay with an IC50 equivalent to 25 (mu) gFB1/g corn and a limit of detection of 3.2 (mu) g/g corn, while affinity cleanup of corn extracts yielded an assay with an IC50 of 5 (mu) gFB1/g corn and a limit of detection of 0.4 (mu) gFB1/g corn. The difference in sensitivity between the two cleanup techniques was due to concentration of fumonisins obtained from the affinity cleanup procedure. Naturally contaminated corn samples were also analyzed after either simple dilution or affinity column cleanup. For comparison the naturally contaminated corn samples were analyzed with an HPLC method after isolation of the fumonisins with strong anion exchange (SAX) solid phase extraction cartridges. The SAX/HPLC method and the immunosensor method agreed well except when large amounts of other fumonisins (i.e. fumonisin B2) were present. This was due in part to the cross-reactivity of the monoclonal antibody with other fumonisins. The immunosensor has the potential to screen individual corn samples for fumonisins within six minutes, and is among the fastest of the currently available FB1 detection methods.

  7. MAMMALIAN DNA IN PCR REAGENTS

    EPA Science Inventory

    Ancient DNA analysis is becoming widespread. These studies use polymerase chain reaction (PCR) to amplify minute quantities of heavily damaged template. Unusual steps are taken to achieve the sensitivity necessary to detect ancient DNA, including high- cycle PCR amplification t...

  8. Possible Detection of Perchlorates by Evolved Gas Analysis of Rocknest Soils: Global Implication

    NASA Technical Reports Server (NTRS)

    Archer, P. D., Jr.; Sutter, B.; Ming, D. W.; McKay, C. P.; Navarro-Gonzalez, R.; Franz, H. B.; McAdam, A.; Mahaffy, P. R.

    2013-01-01

    The Sample Analysis at Mars (SAM) instrument suite on board the Mars Science Laboratory (MSL) recently ran four samples from an aeolian bedform named Rocknest. Rocknest was selected as the source of the first samples analyzed because it is representative of both windblown material in Gale crater as well as the globally-distributed dust. The four samples analyzed by SAM were portioned from the fifth scoop at this location. The material delivered to SAM passed through a 150 m sieve and should have been well mixed during the sample acquisition/ preparation/handoff process. Rocknest samples were heated to 835 C at a 35 C/minute ramp rate with a He carrier gas flow rate of 1.5 standard cubic centimeters per minute and at an oven pressure of 30 mbar. Evolved gases were detected by a quadrupole mass spectrometer (QMS).

  9. A Periodogram of Every Kepler Target and a Common Artifact at ∼80 minutes

    NASA Astrophysics Data System (ADS)

    Kipping, David

    2018-05-01

    Studying photometric time series in the frequency domain can serve as a means of detecting rotational modulations, measuring asteroseismic modes and even detecting short-period transiting planets. To our knowledge, there is no prior archive of the NASA Kepler Mission's power spectra and so we present one here to aid the community in searching for such effects. Using DR25 PDC long-cadence Kepler photometry, 2,594,616 individual periodograms are computed using Welch's method with a Nuttall window, where we provide a unique periododogram for each quarter (up to 16) of each star (196,791 in total). Additionally, we normalize the periodograms in the high-frequency end and combine them into channel- and quarter-averaged power spectra to track common instrumental modes occurring onboard the telescope, with a particularly notable feature at ~80 minutes (~200 $\\mu$Hz) observed.

  10. Industrial-hygiene characterization of ethylene oxide exposures of hospital and nursing-home workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ringenburg, V.L.; Elliott, L.J.; Morelli-Schroth, P.

    Industrial-hygiene surveys were conducted at 12 hospitals and one nursing home to determine possible employee exposure to ethylene oxide (EtO). Different types of exposure situations existed at each of the facilities as a result of various engineering controls, administrative controls and work practices. Sampling indicated that the time-weighted averages (TWAs) of exposure over periods of 36 to 724 minutes ranged from below the limit of detection to 6.7 parts per million (ppm). Personal short-term exposure levels covering 2 to 30 minutes ranged from less than the limit of detection to 103.2ppm. Factors found to be responsible for these higher-than-permissible levelsmore » of EtO exposure included improper installation or lack of engineering controls (such as improper placement of the sterilizing operations), unbalanced ventilation systems, and lack of administrative controls resulting in inappropriate work practices.« less

  11. Solar burst precursors and energy build-up at microwave wavelengths

    NASA Technical Reports Server (NTRS)

    Lang, Kenneth R.; Wilson, Robert F.

    1986-01-01

    We summarize high-resolution microwave observations (VLA) of heating and magnetic triggering in coronal loops. Magnetic changes that precede solar eruptions on time scales of tens of minutes involve primarily emerging coronal loops and the interaction of two or more loops. Thermal cyclotron lines have been detected in coronal loops, suggesting the presence of hot current sheets that enhance emission from relatively thin layers of enhanced temperature and constant magnetic field. These current sheets may play a role in the excitation of solar bursts. A filament-associated source with a high brightness temperature and steep radiation spectrum occurs above a region of apparently weak photospheric field. This source might be attributed to currents that enhance coronal magnetic fields. Compact (phi=5 sec) transient sources with lifetimes of 30 to 60 minutes have also been detected in regions of apparently weak photospheric field. We conclude by comparing VLA observations of coronal loops with simultaneous SMM-XRP observations.

  12. Solar burst precursors and energy build-up at microwave wavelengths

    NASA Astrophysics Data System (ADS)

    Lang, Kenneth R.; Wilson, Robert F.

    We summarize high-resolution microwave observations (VLA) of heating and magnetic triggering in coronal loops. Magnetic changes that precede solar eruptions on time scales of tens of minutes involve primarily emerging coronal loops and the interaction of two or more loops. Thermal cyclotron lines have been detected in coronal loops, suggesting the presence of hot current sheets that enhance emission from relatively thin layers of enhanced temperature and constant magnetic field. These current sheets may play a role in the excitation of solar bursts. A filament-associated source with a high brightness temperature and steep radiation spectrum occurs above a region of apparently weak photospheric field. This source might be attributed to currents that enhance coronal magnetic fields. Compact (phi=5 sec) transient sources with lifetimes of 30 to 60 minutes have also been detected in regions of apparently weak photospheric field. We conclude by comparing VLA observations of coronal loops with simultaneous SMM-XRP observations.

  13. Image processing for improved eye-tracking accuracy

    NASA Technical Reports Server (NTRS)

    Mulligan, J. B.; Watson, A. B. (Principal Investigator)

    1997-01-01

    Video cameras provide a simple, noninvasive method for monitoring a subject's eye movements. An important concept is that of the resolution of the system, which is the smallest eye movement that can be reliably detected. While hardware systems are available that estimate direction of gaze in real-time from a video image of the pupil, such systems must limit image processing to attain real-time performance and are limited to a resolution of about 10 arc minutes. Two ways to improve resolution are discussed. The first is to improve the image processing algorithms that are used to derive an estimate. Off-line analysis of the data can improve resolution by at least one order of magnitude for images of the pupil. A second avenue by which to improve resolution is to increase the optical gain of the imaging setup (i.e., the amount of image motion produced by a given eye rotation). Ophthalmoscopic imaging of retinal blood vessels provides increased optical gain and improved immunity to small head movements but requires a highly sensitive camera. The large number of images involved in a typical experiment imposes great demands on the storage, handling, and processing of data. A major bottleneck had been the real-time digitization and storage of large amounts of video imagery, but recent developments in video compression hardware have made this problem tractable at a reasonable cost. Images of both the retina and the pupil can be analyzed successfully using a basic toolbox of image-processing routines (filtering, correlation, thresholding, etc.), which are, for the most part, well suited to implementation on vectorizing supercomputers.

  14. A Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Method for the Identification of Anthraquinones: the Case of Historical Lakes

    NASA Astrophysics Data System (ADS)

    Sabatini, Francesca; Lluveras-Tenorio, Anna; Degano, Ilaria; Kuckova, Stepanka; Krizova, Iva; Colombini, Maria Perla

    2016-11-01

    This study deals with the identification of anthraquinoid molecular markers in standard dyes, reference lakes, and paint model systems using a micro-invasive and nondestructive technique such as matrix-assisted laser desorption/ionization time-of-flight-mass spectrometry (MALDI-ToF-MS). Red anthraquinoid lakes, such as madder lake, carmine lake, and Indian lac, have been the most widely used for painting purposes since ancient times. From an analytical point of view, identifying lakes in paint samples is challenging and developing methods that maximize the information achievable minimizing the amount of sample needed is of paramount importance. The employed method was tested on less than 0.5 mg of reference samples and required a minimal sample preparation, entailing a hydrofluoric acid extraction. The method is fast and versatile because of the possibility to re-analyze the same sample (once it has been spotted on the steel plate), testing both positive and negative modes in a few minutes. The MALDI mass spectra collected in the two analysis modes were studied and compared with LDI and simulated mass spectra in order to highlight the peculiar behavior of the anthraquinones in the MALDI process. Both ionization modes were assessed for each species. The effect of the different paint binders on dye identification was also evaluated through the analyses of paint model systems. In the end, the method was successful in detecting madder lake in archeological samples from Greek wall paintings and on an Italian funerary clay vessel, demonstrating its capabilities to identify dyes in small amount of highly degraded samples.

  15. Ruthenium Nanoparticles Mediated Electrocatalytic Reduction of UO22+ Ions for Its Rapid and Sensitive Detection in Natural Waters.

    PubMed

    Gupta, Ruma; Sundararajan, Mahesh; Gamare, Jayashree S

    2017-08-01

    Reduction of UO 2 2+ ions to U 4+ ions is difficult due to involvement of two axially bonded oxygen atoms, and often requires a catalyst to lower the activation barrier. The noble metal nanoparticles (NPs) exhibit high electrocatalytic activity, and could be employed for the sensitive and rapid quantifications of U0 2 2+ ions in the aqueous matrix. Therefore, the Pd, Ru, and Rh NPs decorated glassy carbon electrode were examined for their efficacy toward electrocatalytic reduction of UO 2 2+ ions and observed that Ru NPs mediate efficiently the electro-reduction of UO 2 2+ ions. The mechanism of the electroreduction of UO 2 2+ by the RuNPs/GC was studied using density functional theory calculations which pointed different approach of 5f metal ions electroreduction unlike 4p metal ions such as As(III). RuNP decorated on the glassy carbon would be hydrated, which in turn assist to adsorb the uranyl sulfates through hydrogen bonding thus facilitated electro-reduction. Differential pulse voltammetric (DPV) technique, was used for rapid and sensitive quantification of UO 2 2+ ions. The RuNPs/GC based DPV technique could be used to determine the concentration of uranyl in a few minutes with a detection limit of 1.95 ppb. The RuNPs/GC based DPV was evaluated for its analytical performance using seawater as well lake water and groundwater spiked with known amounts of UO 2 2+ .

  16. Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection.

    PubMed

    Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan

    2011-06-01

    Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O(2) content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Low minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor.

    PubMed

    Cavalcante, Alexandre N; Martin, Yvette N; Sprung, Juraj; Imsirovic, Jasmin; Weingarten, Toby N

    2017-12-20

    An electrical impedance-based noninvasive respiratory volume monitor (RVM) accurately reports minute volume, tidal volume and respiratory rate. Here we used the RVM to quantify the occurrence of and evaluate the ability of clinical factors to predict respiratory depression in the post-anesthesia care unit (PACU). RVM generated respiratory data were collected from spontaneously breathing patients following intraperitoneal surgeries under general anesthesia admitted to the PACU. Respiratory depression was defined as low minute ventilation episode (LMVe, < 40% predicted minute ventilation for at least 2 min). We evaluated for associations between clinical variables including minute ventilation prior to opioid administration and LMVe following the first PACU administration of opioid. Also assessed was a low respiratory rate (< 8 breaths per minute) as a proxy for LMVe. Of 107 patients, 38 (36%) had LMVe. Affected patients had greater intraoperative opioid dose, P = 0.05. PACU opioids were administered to 45 (42.1%) subjects, of which 27 (25.2%) had LMVe (P = 0.42) within 30 min following opioid. Pre-opioid minute ventilation < 70% of predicted normal value was associated with LMVe, P < 0.01, (sensitivity = 100%, specificity = 81%).Low respiratory rate was a poor predictor of LMVe (sensitivity = 11.8%). Other clinical variables (e.g., obstructive sleep apnea) were not found to be predictors of LMVe. Using RVM we identified that mild, clinically nondetectable, respiratory depression prior to opioid administration in the PACU was associated with the development of substantial subsequent respiratory depression during the PACU stay.

  18. Highly Sensitive GMO Detection Using Real-Time PCR with a Large Amount of DNA Template: Single-Laboratory Validation.

    PubMed

    Mano, Junichi; Hatano, Shuko; Nagatomi, Yasuaki; Futo, Satoshi; Takabatake, Reona; Kitta, Kazumi

    2018-03-01

    Current genetically modified organism (GMO) detection methods allow for sensitive detection. However, a further increase in sensitivity will enable more efficient testing for large grain samples and reliable testing for processed foods. In this study, we investigated real-time PCR-based GMO detection methods using a large amount of DNA template. We selected target sequences that are commonly introduced into many kinds of GM crops, i.e., 35S promoter and nopaline synthase (NOS) terminator. This makes the newly developed method applicable to a wide range of GMOs, including some unauthorized ones. The estimated LOD of the new method was 0.005% of GM maize events; to the best of our knowledge, this method is the most sensitive among the GM maize detection methods for which the LOD was evaluated in terms of GMO content. A 10-fold increase in the DNA amount as compared with the amount used under common testing conditions gave an approximately 10-fold reduction in the LOD without PCR inhibition. Our method is applicable to various analytical samples, including processed foods. The use of other primers and fluorescence probes would permit highly sensitive detection of various recombinant DNA sequences besides the 35S promoter and NOS terminator.

  19. High-density array-CGH with targeted NGS unmask multiple noncontiguous minute deletions on chromosome 3p21 in mesothelioma.

    PubMed

    Yoshikawa, Yoshie; Emi, Mitsuru; Hashimoto-Tamaoki, Tomoko; Ohmuraya, Masaki; Sato, Ayuko; Tsujimura, Tohru; Hasegawa, Seiki; Nakano, Takashi; Nasu, Masaki; Pastorino, Sandra; Szymiczek, Agata; Bononi, Angela; Tanji, Mika; Pagano, Ian; Gaudino, Giovanni; Napolitano, Andrea; Goparaju, Chandra; Pass, Harvey I; Yang, Haining; Carbone, Michele

    2016-11-22

    We used a custom-made comparative genomic hybridization array (aCGH; average probe interval 254 bp) to screen 33 malignant mesothelioma (MM) biopsies for somatic copy number loss throughout the 3p21 region (10.7 Mb) that harbors 251 genes, including BRCA1 (breast cancer 1)-associated protein 1 (BAP1), the most commonly mutated gene in MM. We identified frequent minute biallelic deletions (<3 kb) in 46 of 251 genes: four were cancer-associated genes: SETD2 (SET domain-containing protein 2) (7 of 33), BAP1 (8 of 33), PBRM1 (polybromo 1) (3 of 33), and SMARCC1 (switch/sucrose nonfermentable- SWI/SNF-related, matrix-associated, actin-dependent regulator of chromatin, subfamily c, member 1) (2 of 33). These four genes were further investigated by targeted next-generation sequencing (tNGS), which revealed sequence-level mutations causing biallelic inactivation. Combined high-density aCGH and tNGS revealed biallelic gene inactivation in SETD2 (9 of 33, 27%), BAP1 (16 of 33, 48%), PBRM1 (5 of 33, 15%), and SMARCC1 (2 of 33, 6%). The incidence of genetic alterations detected is much higher than reported in the literature because minute deletions are not detected by NGS or commercial aCGH. Many of these minute deletions were not contiguous, but rather alternated with segments showing oscillating copy number changes along the 3p21 region. In summary, we found that in MM: (i) multiple minute simultaneous biallelic deletions are frequent in chromosome 3p21, where they occur as distinct events involving multiple genes; (ii) in addition to BAP1, mutations of SETD2, PBRM1, and SMARCC1 are frequent in MM; and (iii) our results suggest that high-density aCGH combined with tNGS provides a more precise estimate of the frequency and types of genes inactivated in human cancer than approaches based exclusively on NGS strategy.

  20. Biodistribution and Clearance of Human Mesenchymal Stem Cells by Quantitative Three-Dimensional Cryo-Imaging After Intravenous Infusion in a Rat Lung Injury Model.

    PubMed

    Schmuck, Eric G; Koch, Jill M; Centanni, John M; Hacker, Timothy A; Braun, Rudolf K; Eldridge, Marlowe; Hei, Derek J; Hematti, Peiman; Raval, Amish N

    2016-12-01

    : Cell tracking is a critical component of the safety and efficacy evaluation of therapeutic cell products. To date, cell-tracking modalities have been hampered by poor resolution, low sensitivity, and inability to track cells beyond the shortterm. Three-dimensional (3D) cryo-imaging coregisters fluorescent and bright-field microcopy images and allows for single-cell quantification within a 3D organ volume. We hypothesized that 3D cryo-imaging could be used to measure cell biodistribution and clearance after intravenous infusion in a rat lung injury model compared with normal rats. A bleomycin lung injury model was established in Sprague-Dawley rats (n = 12). Human mesenchymal stem cells (hMSCs) labeled with QTracker655 were infused via jugular vein. After 2, 4, or 8 days, a second dose of hMSCs labeled with QTracker605 was infused, and animals were euthanized after 60, 120, or 240 minutes. Lungs, liver, spleen, heart, kidney, testis, and intestine were cryopreserved, followed by 3D cryo-imaging of each organ. At 60 minutes, 82% ± 9.7% of cells were detected; detection decreased to 60% ± 17% and 66% ± 22% at 120 and 240 minutes, respectively. At day 2, 0.06% of cells were detected, and this level remained constant at days 4 and 8 postinfusion. At 60, 120, and 240 minutes, 99.7% of detected cells were found in the liver, lungs, and spleen, with cells primarily retained in the liver. This is the first study using 3D cryo-imaging to track hMSCs in a rat lung injury model. hMSCs were retained primarily in the liver, with fewer detected in lungs and spleen. Effective bench-to-bedside clinical translation of cellular therapies requires careful understanding of cell fate through tracking. Tracking cells is important to measure cell retention so that delivery methods and cell dose can be optimized and so that biodistribution and clearance can be defined to better understand potential off-target toxicity and redosing strategies. This article demonstrates, for the first time, the use of three-dimensional cryo-imaging for single-cell quantitative tracking of intravenous infused clinical-grade mesenchymal stem cells in a clinically relevant model of lung injury. The important information learned in this study will help guide future clinical and translational stem cell therapies for lung injuries. ©AlphaMed Press.

  1. [Study on extraction process of Radix Bupleuri].

    PubMed

    Zhao, Lei; Liu, Benliang; Wu, Fuxiang; Tao, Lanping; Liu, Jian

    2004-10-01

    The orthogonal design was used to optimize extraction process of Radix Bupleuri with content of total saponin and yield of the extract as markers. Factors that have been chosen were ethanol concentration, ethanol consumption, extraction times and extraction time. Each factor had three levels. The result showed that the optimum extraction condition was 80% ethanol, 4 times the amount of material, refluxing for 4 times, 60 minutes each time. The optimized process was stable and workable.

  2. Studies of Verbal Problem Solving. 1. Two Performance-Aiding Programs

    DTIC Science & Technology

    1977-09-01

    5. Effective Date of Contract 6. Contract Expiration Date 7. Amount of Contract 8. Contract Number 9. Principal Investigator 10 . Scientific...7 10 3. A Mystery Solved by Propositional Calculus 16 1v I. INTRODUCTION Certain intellectual tasks, such as estimating and combining prob...aids or without any special training, they get the right answer within 15 minutes or so (about 80% of one large psychology class solved it). A few

  3. Minutes of the Explosives Safety Seminar (24th) Held in St. Louis, Missouri on 28-30 August 1990. Volume 1

    DTIC Science & Technology

    1990-08-30

    concrete-soil-concrete and other soil-filled elements as well as earth embankments of different shapes. The design of the shielding external walls...to vent entirely through the doors. This was required because the large amount of earth fill on the roofs, required for radiation shielding , precluded...Safety Window Shield to Protect Against External Explosions ...... ............... ................... 783 R. L. Shope, W. A. Keenan Strenghtening

  4. [Monitoring of methyl methacrylate monomer released from autopolymerized denture base polymers during processing using time-of-flight mass spectrometer].

    PubMed

    Ma, Yu-juan; Cui, Hua-peng; Li, Hai-yang

    2011-04-01

    To analyze the amount and tendency of methyl methacrylate (MMA) released from autopolymerized denture base polymer (self-curing resin) during processing using time-of-flight mass spectrometer (TOF-MS). Self-curing resin was mixed in the container using a ratio of 2 g of powder to 1 g of liquid in accordance with the manufacturer's instructions for 40 s as a specimen. The amount of MMA released from the specimen was continuously monitored and simultaneously recorded every minute by TOF-MS since immediately after mixing. A total of five specimens were monitored. The amount of MMA increased dramatically at 11 min [(45.2 ± 3.5) mg/L] after mixing, and reached the highest level at 13 min [(228.9 ± 22.6) mg/L], then become stable at 23 min [(8.8 ± 2.3) mg/L] after mixing. The releasing tendency of MMA could be analyzed accurately with continuously monitoring during processing. The amount of MMA released from self-curing resin changed rapidly and the processing was complicated and changeful.

  5. Life-saving automated external defibrillation in a teenager: a case report

    PubMed Central

    Rey, Corsino; Rodríguez-Nuñez, Antonio; Medina, Alberto; Mayordomo, Juan

    2007-01-01

    Background Adolescent sudden death during sport participation is commonly due to cardiac causes. Survival is more likely when an automated external defibrillator (AED) is used soon after collapse. Case presentation We describe a case of sudden death in a 14 year old boy with two remarkable points, successful resuscitation at school using an AED and diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC). Bystander cardiopulmonary resuscitation (CPR) was immediately started by a witness and 5 minutes after the event the child was placed on an AED monitor that determined he was in a non shockable rhythm, therefore CPR was continued. Two minutes later, the AED monitor detected a shockable rhythm and recommended a shock, which was then administered. One minute after the shock, a palpable pulse was detected and the child began to breathe by himself. Four days after cardiac arrest, the boy was conversing and self-caring. Cardiac magnetic resonance imaging was suggestive of ARVC. Conclusion Ventricular fibrillation secondary to ARVC may be a devastating event and places young patients and athletes at high risk of sudden death. Immediate CPR and AED have been demonstrated to be lifesaving in such events. Therefore, we suggest that schools should have teachers skilled in CPR and accessible AEDs. PMID:17767706

  6. Fast Gradient Elution Reversed-Phase HPLC with Diode-Array Detection as a High Throughput Screening Method for Drugs of Abuse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peter W. Carr; K.M. Fuller; D.R. Stoll

    A new approach has been developed by modifying a conventional gradient elution liquid chromatograph for the high throughput screening of biological samples to detect the presence of regulated intoxicants. The goal of this work was to improve the speed of a gradient elution screening method over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which are the basis for the identification. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between gradient runs, thereby reducing the total time for eachmore » analysis. The total analysis time for each gradient elution run is only 2.8 minutes, including 0.3 minutes for column reequilibration between analyses. Retention times standard calibration solutes are reproducible to better than 0.002 minutes in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. The discriminating power and mean list length were calculated for a library of 47 intoxicants and compared with previous work from other laboratories to evaluate fast gradient elution HPLC as a screening tool.« less

  7. Fiber-Optic Based Compact Gas Leak Detection System

    NASA Technical Reports Server (NTRS)

    deGroot, Wim A.

    1995-01-01

    A propellant leak detection system based on Raman scattering principles is introduced. The proposed system is flexible and versatile as the result of the use of optical fibers. It is shown that multiple species can be monitored simultaneously. In this paper oxygen, nitrogen, carbon monoxide, and hydrogen are detected and monitored. The current detection sensitivity for both hydrogen and carbon monoxide is 1% partial pressure at ambient conditions. The sensitivity for oxygen and nitrogen is 0.5% partial pressure. The response time to changes in species concentration is three minutes. This system can be used to monitor multiple species at several locations.

  8. Amount of Time in Print Reading in General Education Kindergarten Classrooms: What Does It Look Like for Students At-risk for Reading Difficulties?

    PubMed Central

    Kent, Shawn C.; Wanzek, Jeanne; Al Otaiba, Stephanie

    2012-01-01

    The purpose of this study was to examine the amount of time spent actively engaged in reading sounds, words, and connected text for students at-risk for reading difficulties in the first formal grade of reading instruction, kindergarten. Observational data of 109 kindergarten students at high-risk for later reading difficulties were collected during general education reading instruction across the school year. Findings revealed students read orally for just over 1 minute during their reading instruction with approximately equal time spent reading sounds, words, or connected text. Implications of these results for early reading instruction and intervention for students at-risk for reading difficulties or disabilities are presented. PMID:23087545

  9. Using trend templates in a neonatal seizure algorithm improves detection of short seizures in a foetal ovine model.

    PubMed

    Zwanenburg, Alex; Andriessen, Peter; Jellema, Reint K; Niemarkt, Hendrik J; Wolfs, Tim G A M; Kramer, Boris W; Delhaas, Tammo

    2015-03-01

    Seizures below one minute in duration are difficult to assess correctly using seizure detection algorithms. We aimed to improve neonatal detection algorithm performance for short seizures through the use of trend templates for seizure onset and end. Bipolar EEG were recorded within a transiently asphyxiated ovine model at 0.7 gestational age, a common experimental model for studying brain development in humans of 30-34 weeks of gestation. Transient asphyxia led to electrographic seizures within 6-8 h. A total of 3159 seizures, 2386 shorter than one minute, were annotated in 1976 h-long EEG recordings from 17 foetal lambs. To capture EEG characteristics, five features, sensitive to seizures, were calculated and used to derive trend information. Feature values and trend information were used as input for support vector machine classification and subsequently post-processed. Performance metrics, calculated after post-processing, were compared between analyses with and without employing trend information. Detector performance was assessed after five-fold cross-validation conducted ten times with random splits. The use of trend templates for seizure onset and end in a neonatal seizure detection algorithm significantly improves the correct detection of short seizures using two-channel EEG recordings from 54.3% (52.6-56.1) to 59.5% (58.5-59.9) at FDR 2.0 (median (range); p < 0.001, Wilcoxon signed rank test). Using trend templates might therefore aid in detection of short seizures by EEG monitoring at the NICU.

  10. Ultrafast, sensitive and large-volume on-chip real-time PCR for the molecular diagnosis of bacterial and viral infections.

    PubMed

    Houssin, Timothée; Cramer, Jérémy; Grojsman, Rébecca; Bellahsene, Lyes; Colas, Guillaume; Moulet, Hélène; Minnella, Walter; Pannetier, Christophe; Leberre, Maël; Plecis, Adrien; Chen, Yong

    2016-04-21

    To control future infectious disease outbreaks, like the 2014 Ebola epidemic, it is necessary to develop ultrafast molecular assays enabling rapid and sensitive diagnoses. To that end, several ultrafast real-time PCR systems have been previously developed, but they present issues that hinder their wide adoption, notably regarding their sensitivity and detection volume. An ultrafast, sensitive and large-volume real-time PCR system based on microfluidic thermalization is presented herein. The method is based on the circulation of pre-heated liquids in a microfluidic chip that thermalize the PCR chamber by diffusion and ultrafast flow switches. The system can achieve up to 30 real-time PCR cycles in around 2 minutes, which makes it the fastest PCR thermalization system for regular sample volume to the best of our knowledge. After biochemical optimization, anthrax and Ebola simulating agents could be respectively detected by a real-time PCR in 7 minutes and a reverse transcription real-time PCR in 7.5 minutes. These detections are respectively 6.4 and 7.2 times faster than with an off-the-shelf apparatus, while conserving real-time PCR sample volume, efficiency, selectivity and sensitivity. The high-speed thermalization also enabled us to perform sharp melting curve analyses in only 20 s and to discriminate amplicons of different lengths by rapid real-time PCR. This real-time PCR microfluidic thermalization system is cost-effective, versatile and can be then further developed for point-of-care, multiplexed, ultrafast and highly sensitive molecular diagnoses of bacterial and viral diseases.

  11. Comparison of two- and six-minute walk tests in detecting oxygen desaturation in patients with severe chronic obstructive pulmonary disease — A randomized crossover trial

    PubMed Central

    Teschler, Sebastian; Jarosch, Inga; Christle, Jeffrey W; Hitzl, Wolfgang; Kenn, Klaus

    2016-01-01

    The two-minute walk test (2MWT) is less well validated than the well-known six-minute walk test (6MWT) as a field walking test in patients with chronic obstructive pulmonary disease (COPD). The primary objective of this study was to compare the accuracy of the 2MWT to the 6MWT in detecting exercise-induced oxygen desaturation in patients with severe COPD. Twenty-six patients with COPD (age: 61 ± 10 years, forced expired volume in one second: 37 ± 10%) that were normoxemic at rest performed a 2MWT and a 6MWT under normal ambient conditions on two consecutive days in random order. Oxygen saturation, total walking distance, heart rate, breathing frequency, dyspnea, and leg fatigue were evaluated. Average walking distances were 150 m (95% confidence interval (95% CI): 134–165 m) and 397 m (95% CI: 347–447 m) for the 2MWT and 6MWT, respectively (r = 0.80, p < 0.0001). The difference in minimum oxygen saturation during the 2MWT (83%, 95% CI: 81–86%) and 6MWT (mean 82%, 95% CI: 80–84%) was not statistically different and the data strongly correlated between the groups (r = 0.81, p < 0.0001). Other measurements from the 6MWT, including heart rate, breathing rate, and levels of perceived exertion were also comparable in 2MWT. The 2MWT showed comparable validity in detecting exercise-induced oxygen desaturation in patients with severe COPD compared to the 6MWT. PMID:26961775

  12. Comparison of two- and six-minute walk tests in detecting oxygen desaturation in patients with severe chronic obstructive pulmonary disease - A randomized crossover trial.

    PubMed

    Gloeckl, Rainer; Teschler, Sebastian; Jarosch, Inga; Christle, Jeffrey W; Hitzl, Wolfgang; Kenn, Klaus

    2016-03-08

    The two-minute walk test (2MWT) is less well validated than the well-known six-minute walk test (6MWT) as a field walking test in patients with chronic obstructive pulmonary disease (COPD). The primary objective of this study was to compare the accuracy of the 2MWT to the 6MWT in detecting exercise-induced oxygen desaturation in patients with severe COPD. Twenty-six patients with COPD (age: 61 ± 10 years, forced expired volume in one second: 37 ± 10%) that were normoxemic at rest performed a 2MWT and a 6MWT under normal ambient conditions on two consecutive days in random order. Oxygen saturation, total walking distance, heart rate, breathing frequency, dyspnea, and leg fatigue were evaluated. Average walking distances were 150 m (95% confidence interval (95% CI): 134-165 m) and 397 m (95% CI: 347-447 m) for the 2MWT and 6MWT, respectively (r = 0.80, p < 0.0001). The difference in minimum oxygen saturation during the 2MWT (83%, 95% CI: 81-86%) and 6MWT (mean 82%, 95% CI: 80-84%) was not statistically different and the data strongly correlated between the groups (r = 0.81, p < 0.0001). Other measurements from the 6MWT, including heart rate, breathing rate, and levels of perceived exertion were also comparable in 2MWT. The 2MWT showed comparable validity in detecting exercise-induced oxygen desaturation in patients with severe COPD compared to the 6MWT. © The Author(s) 2016.

  13. Detection of CO2 leakage by the surface-soil CO2-concentration monitoring (SCM) system in a small scale CO2 release test

    NASA Astrophysics Data System (ADS)

    Chae, Gitak; Yu, Soonyoung; Sung, Ki-Sung; Choi, Byoung-Young; Park, Jinyoung; Han, Raehee; Kim, Jeong-Chan; Park, Kwon Gyu

    2015-04-01

    Monitoring of CO2 release through the ground surface is essential to testify the safety of CO2 storage projects. We conducted a feasibility study of the multi-channel surface-soil CO2-concentration monitoring (SCM) system as a soil CO2 monitoring tool with a small scale injection. In the system, chambers are attached onto the ground surface, and NDIR sensors installed in each chamber detect CO2 in soil gas released through the soil surface. Before injection, the background CO2 concentrations were measured. They showed the distinct diurnal variation, and were positively related with relative humidity, but negatively with temperature. The negative relation of CO2 measurements with temperature and the low CO2 concentrations during the day imply that CO2 depends on respiration. The daily variation of CO2 concentrations was damped with precipitation, which can be explained by dissolution of CO2 and gas release out of pores through the ground surface with recharge. For the injection test, 4.2 kg of CO2 was injected 1 m below the ground for about 30 minutes. In result, CO2 concentrations increased in all five chambers, which were located less than 2.5 m of distance from an injection point. The Chamber 1, which is closest to the injection point, showed the largest increase of CO2 concentrations; while Chamber 2, 3, and 4 showed the peak which is 2 times higher than the average of background CO2. The CO2 concentrations increased back after decreasing from the peak around 4 hours after the injection ended in Chamber 2, 4, and 5, which indicated that CO2 concentrations seem to be recovered to the background around 4 hours after the injection ended. To determine the leakage, the data in Chamber 2 and 5, which had low increase rates in the CO2 injection test, were used for statistical analysis. The result shows that the coefficient of variation (CV) of CO2 measurements for 30 minutes is efficient to determine a leakage signal, with reflecting the abnormal change in CO2 concentrations. The CV of CO2 measurements for 30 minutes exceeded 5% about 5 minutes before the maximum CO2 concentration was detected. The contributions of this work are as follows: (1) SCM is an efficient monitoring tool to detect the CO2 release through the ground surface. (2) The statistical analysis method to determine the leakage and a monitoring frequency are provided, with analyzing background concentrations and CO2 increases in a small-scale injection test. (3) The 5% CV of CO2 measurements for 30 minutes can be used for the early warning in CO2 storage sites.

  14. Perforation of the Right Ventricle Induced by Pulmonary Artery Catheter at Induction of Anesthesia for the Surgery for Liver Transplantation: A Case Report and Reviewed of Literature

    PubMed Central

    Auxiliadora-Martins, Maria; Apinagés dos Santos, Erick; Adans Wenzinger, Daniel; Alkmim-Teixeira, Gil Cezar; Neto, Gerardo Cristino de M.; Sankarankutty, Ajith Kumar; de Castro e Silva, Orlando; Martins-Filho, Olindo Assis; Basile-Filho, Anibal

    2009-01-01

    We report a case of a 45-year-old male patient diagnosed with liver cirrhosis by hepatitis C and alcohol, with a Child-Pugh score C and a model for end-stage liver disease (MELD) score of 27, and submitted to liver transplantation. The subject underwent insertion of the pulmonary artery catheter (PAC) in the right internal jugular vein, with technical difficulty concerning catheter advance. There was sudden hypotension, increase in central venous pressure (CVP), and decrease in SvO2 15 minutes after the PAC had been inserted, followed by cardiorespiratory arrest in pulseless electrical activity (PEA), which was promptly assisted with resuscitation. Pericardiocentesis was performed without success, so the individual was subjected to a subxiphoid pericardial window, which led to output of large amounts of blood as well as PEA reversal to sinus rhythm. Sternotomy was performed; rupture of the apex of the right ventricle (RV) was detected, and suture of the site was accomplished. After hemodynamic stabilization, the patient was transferred to the ICU, where he developed septic shock and, despite adequate therapy, died on the eighteenth day after ICU admission. PMID:20066172

  15. Water on the Moon Confirmed

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    2009-11-01

    When NASA's Lunar Crater Observation and Sensing Satellite (LCROSS) and a companion rocket purposely slammed into a crater at the Moon's south pole on 9 October, some observers on Earth lamented as anticlimactic the raised plumes of material that were partially blocked by a crater ridge and were difficult to see with backyard telescopes. However, it turns out that the projectiles struck it big. “Indeed, yes, we found water. We didn’t find just a little bit; we found a significant amount,” said Anthony Colaprete, LCROSS principal investigator with the NASA Ames Research Center, Moffett Field, Calif. At a 13 November news briefing, Colaprete lifted a 2-gallon plastic bucket and said preliminary results indicate that instruments detected about a dozen buckets' worth of water in parts of the two plumes, the first generated by the spent Centaur upper stage of the Atlas V launch vehicle at 1131 UTC and the second generated by LCROSS about 4 minutes later. NASA described the two plumes as a high-angle plume of vapor and fine dust and a lower-angle ejecta curtain of heavier material. LCROSS and the Centaur upper stage hit the permanently shadowed Cabeus crater.

  16. Probing sialoglycans on fetal bovine fetuin with azido-sugars using glycosyltransferases.

    PubMed

    Wu, Zhengliang L; Huang, Xinyi; Burton, Andrew J; Swift, Karl A D

    2016-04-01

    Sialic acids are negatively charged sugar residues commonly found on the terminal positions of most glycoproteins. They play important roles in the stability and solubility of these proteins. Due to their unique positioning, they also frequently act as receptors for various ligands, and therefore are involved in numerous cell-cell and cell-pathogen interactions. Here, using in vitro incorporation of clickable monosaccharides with various glycosyltransferases, we probed the sialoglycans on fetal bovine fetuin. The incorporated monosaccharides were detected with chemiluminescence via click chemistry in a format of western blotting. The results indicate that the non-reducing end Gal residues on both N- and O-glycans are fully sialylated, but the peptide-linked GalNAc residues in O-glycans are not. The presence of sialyl core-1 glycan was repeatedly confirmed by probing with α-2,3-sialyltransferases, N-acetylgalactosaminide α-2,6-sialyltransferases and a β-1,6-N-acetylglucosaminyltransferase that is specific for core-1 glycan. The results also suggest the presence of a minute amount of sialyl Tn antigen on the protein. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. A simple and rapid method for high-resolution visualization of single-ion tracks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omichi, Masaaki; Center for Collaborative Research, Anan National College of Technology, Anan, Tokushima 774-0017; Choi, Wookjin

    2014-11-15

    Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA)-N, N’-methylene bisacrylamide (MBAAm) blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic forcemore » microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.« less

  18. Thallium release from acid mine drainages: Speciation in river and tap water from Valdicastello mining district (northwest Tuscany).

    PubMed

    Campanella, Beatrice; Casiot, Corinne; Onor, Massimo; Perotti, Martina; Petrini, Riccardo; Bramanti, Emilia

    2017-08-15

    In this work we present an advantageous method for the simultaneous separation and detection of Tl(I) and Tl(III) species through ion chromatography coupled with on-line inductively coupled plasma - mass spectrometry. Chromatographic separation between Tl(III) and Tl(I) was achieved in less than two minutes. The method was validated by recovery experiments on real samples, and by comparing the sum of the concentrations of individual Tl species with total thallium values obtained from continuous flow ICP-MS. The experimental procedure offers an accurate, sensitive and interference-free method for Tl speciation at trace levels in environmental samples. This allowed us to investigate the Tl speciation in acid mine drainages (AMD), surface waters and springs in a mining catchment in Valdicastello Carducci (Tuscany, Italy), where severe Tl contamination ad been evidenced previously. This study shows for the first time that Tl(III), in addition to Tl(I), is present in considerable amounts in water samples affected by acid mining outflow, raising the question of the origin of this thermodynamically unstable species. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. STUDIES ON THE PATHOGENESIS OF FEVER

    PubMed Central

    Petersdorf, Robert G.; Bennett, Ivan L.

    1957-01-01

    Intravenous administration of bacterial endotoxins in dogs is followed within 2 hours by the appearance of a fever-producing substance in the blood. This endogenous pyrogen differs from the endotoxins originally administered by its ability to produce fever in tolerant recipients and failure to promote tolerance after repeated daily injections. Endogenous serum pyrogen is destroyed by heating at 90°C. for 30 minutes, and is also inactivated to some degree by incubation at 37°C. for 24 hours. Suppression of fever by aminopyrine does not affect appearance of the endogenous factor. Animals made febrile with dinitrophenol, kaolin, or lysergic acid do not elaborate a fever-promoting substance in the blood. Sterile abscesses, accompanied by elevations in body temperature of the host, are unassociated with detectable amounts of secondary pyrogen in the serum. The absence of endogenous pyrogen in the blood of febrile dogs made leukopenic with nitrogen mustard favors the idea that polymorphonuclear leukocytes injured by endotoxins release the endogenous factor. On the other hand, the finding that the granulocytopenic animals are febrile when no circulating endogenous pyrogen is present, casts doubt upon the essential role of this substance in endotoxin fever. PMID:13449238

  20. Remembering operations.

    PubMed

    Kolers, P A

    1973-09-01

    Two commonplace assumptions about encoding are that sentences are encoded and recognized on the basis of their semantic features primarily and that information regarding form features such as typography is typically ignored or discarded. These assumptions were tested m the present experiment where, within a signal-detection paradigm, S sorted sentences according to whether he had seen them before or not (old vs new) and, if they were old, whether their reappearance was in the same typography as on the first occurrence or a different one. Of the two typographies, one was familiar and the other unfamiliar. Results show that a considerable amount of information regarding surface features is stored for many minutes and that ease of initial encoding is inversely related to likelihood of subsequent recognition: sentences in the unfamiliar typography were remembered better. The results are probably not due to time spent encoding; control tests suggest that time spent encoding a difficult typography does not by itself increase recognition of the semantic content embodied in the typography. Other control tests show that pictorial features or images of the sentences play no significant role in their subsequent recognition. One interpretation of the results is that the analytic activities or cognitive operations that characterize initial acquisition play a significant role in subsequent recognition.

Top