Determining the maximum charging currents of lithium-ion cells for small charge quantities
NASA Astrophysics Data System (ADS)
Grimsmann, F.; Gerbert, T.; Brauchle, F.; Gruhle, A.; Parisi, J.; Knipper, M.
2017-10-01
In order to optimize the operating parameters of battery management systems for electric and hybrid vehicles, great interest has been shown in achieving the maximum permissible charging currents during recuperation, without causing a cell damage due to lithium plating, in relation to the temperature, charge quantity and state of charge. One method for determining these recuperation currents is measuring the cell thickness, where excessively high charging currents can be detected by an irreversible increase in thickness. It is not possible to measure particularly small charge quantities by employing mechanic dial indicators, which have a limited resolution of 1 μm. This is why we developed a measuring setup that has a resolution limit of less than 10 nm using a high-resolution contactless inductance sensor. Our results show that the permissible charging current I can be approximated in relation to the charge quantity x by a correlating function I =a /√{(x) } which is compliant with the Arrhenius law. Small charge quantities therefore have an optimization potential for energy recovery during recuperation.
A method for detecting small targets based on cumulative weighted value of target properties
NASA Astrophysics Data System (ADS)
Jin, Xing; Sun, Gang; Wang, Wei-hua; Liu, Fang; Chen, Zeng-ping
2015-03-01
Laser detection based on the "cat's eye effect" has become the hot research project for its initiative compared to the passivity of sound detection and infrared detection. And the target detection is one of the core technologies in this system. The paper puts forward a method for detecting small targets based on cumulative weighted value of target properties using given data. Firstly, we make a frame difference to the images, then make image processing based on Morphology Principles. Secondly, we segment images, and screen the targets; then find some interesting locations. Finally, comparing to a quantity of frames, we locate the target. We did an exam to 394 true frames, the experimental result shows that the mathod can detect small targets efficiently.
Fukuda, Masakazu; Watanabe, Atsushi; Hayasaka, Akira; Muraoka, Masaru; Hori, Yuji; Yamazaki, Tadao; Imaeda, Yoshimi; Koga, Akiko
2017-03-01
In this study, we investigated the concentration range in which self-association starts to form in humanized IgG monoclonal antibody (mAb) solutions. Furthermore, on the basis of the results, we developed a practical method of screening for low-viscosity antibody solutions by using small-angle X-ray scattering (SAXS) measurements utilizing small quantities of samples. With lower-viscosity mAb3, self-association was not detected in the range of 1-80mg/mL. With higher-viscosity mAb1, on the other hand, self-association was detected in the range of 10-20mg/mL and was clearly enhanced by a decrease in temperature. The viscosities of mAb solutions at 160, 180, and 200mg/mL at 25°C quantitatively correlated very well with the particle size parameters obtained by SAXS measurements of mAb solutions at 15mg/mL at 5°C. The quantity of mAb sample required for the SAXS measurements was only 0.15mg, which is about one-hundredth of that required for actual viscosity measurements at a high concentration, and such quantities could be available even at an early stage of development. In conclusion, the SAXS analysis method proposed in this study is a valuable tool for the development of concentrated mAb therapeutics with high manufacturability and high usability for subcutaneous injection. Copyright © 2016 Elsevier B.V. All rights reserved.
Metal-Assisted Laser-Induced Gas Plasma for the Direct Analysis of Powder Using Pulse CO2 Laser
NASA Astrophysics Data System (ADS)
Khumaeni, A.; Lie, Z. S.; Kurniawan, K. H.; Kagawa, K.
2017-01-01
Analysis of powder samples available in small quantities has been carried out using metal-assisted gas plasma by utilizing a transversely excited atmospheric (TEA) CO2 laser. The powder was homogeneously mixed with Si grease, and the mixed powder was painted on a metal subtarget. When a TEA CO2 laser was directly focused on the metal subtarget at atmospheric pressure of He gas, a high-temperature He gas plasma was induced. It is assumed that the powder particles were vaporized to be effectively atomized and excited in the gas plasma region. This method has been employed in the rapid analyses of elements in organic and inorganic powder samples present in small quantities. Detection of trace elements of Cr and Pb has been successfully made by using the supplement powder and loam soil, respectively. The detection limits of Pb in loam soil were approximately 20 mg/kg.
Differential transimpedance amplifier circuit for correlated differential amplification
Gresham, Christopher A [Albuquerque, NM; Denton, M Bonner [Tucson, AZ; Sperline, Roger P [Tucson, AZ
2008-07-22
A differential transimpedance amplifier circuit for correlated differential amplification. The amplifier circuit increase electronic signal-to-noise ratios in charge detection circuits designed for the detection of very small quantities of electrical charge and/or very weak electromagnetic waves. A differential, integrating capacitive transimpedance amplifier integrated circuit comprising capacitor feedback loops performs time-correlated subtraction of noise.
Fukushima derived radiocesium in subsistence-consumed northern fur seal and wild celery
Ruedig, Elizabeth; Duncan, Colleen; Dickerson, Bobette; ...
2015-11-28
In July 2014, our investigative team traveled to St. Paul Island, Alaska to measure concentrations of radiocesium in wild-caught food products, primarily northern fur seal (Callorhinus ursinus). The 2011 Fukushima Daiichi Nuclear Power Plant accident released radiocesium into the atmosphere and into the western Pacific Ocean; other investigators have detected Fukushima-derived radionuclides in a variety of marine products harvested off the western coast of North America. We tested two subsistence-consumed food products from St. Paul Island, Alaska for Fukushima-derived radionuclides: 54 northern fur seal, and nine putchki (wild celery, Angelica lucida) plants. Individual northern fur seal samples were below minimummore » detectable activity concentrations of 137Cs and 134Cs, but when composited, northern fur seal tissues tested positive for trace quantities of both isotopes. Radiocesium was detected at an activity concentration of 37.2 mBq 134Cs kg -1 f.w. (95% CI: 35.9–38.5) and 141.2 mBq 137Cs kg -1f.w. (95% CI: 135.5–146.8). The measured isotopic ratio, decay-corrected to the date of harvest, was 0.26 (95% CI: 0.25–0.28). The Fukushima nuclear accident released 134Cs and 137Cs in roughly equal quantities, but by the date of harvest in July 2014, this ratio was 0.2774, indicating that this population of seals has been exposed to small quantities of Fukushima-derived radiocesium. Activity concentrations of both 134Cs and 137Cs in putchki were below detection limits, even for composited samples. Northern fur seal is known to migrate between coastal Alaska and Japan and the trace 134Cs in northern fur seal tissue suggests that the population under study had been minimally exposed Fukushima-derived radionuclides. Despite this inference, the radionuclide quantities detected are small and no impact is expected as a result of the measured radiation exposure, either in northern fur seal or human populations consuming this species.« less
Fukushima derived radiocesium in subsistence-consumed northern fur seal and wild celery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruedig, Elizabeth; Duncan, Colleen; Dickerson, Bobette
In July 2014, our investigative team traveled to St. Paul Island, Alaska to measure concentrations of radiocesium in wild-caught food products, primarily northern fur seal (Callorhinus ursinus). The 2011 Fukushima Daiichi Nuclear Power Plant accident released radiocesium into the atmosphere and into the western Pacific Ocean; other investigators have detected Fukushima-derived radionuclides in a variety of marine products harvested off the western coast of North America. We tested two subsistence-consumed food products from St. Paul Island, Alaska for Fukushima-derived radionuclides: 54 northern fur seal, and nine putchki (wild celery, Angelica lucida) plants. Individual northern fur seal samples were below minimummore » detectable activity concentrations of 137Cs and 134Cs, but when composited, northern fur seal tissues tested positive for trace quantities of both isotopes. Radiocesium was detected at an activity concentration of 37.2 mBq 134Cs kg -1 f.w. (95% CI: 35.9–38.5) and 141.2 mBq 137Cs kg -1f.w. (95% CI: 135.5–146.8). The measured isotopic ratio, decay-corrected to the date of harvest, was 0.26 (95% CI: 0.25–0.28). The Fukushima nuclear accident released 134Cs and 137Cs in roughly equal quantities, but by the date of harvest in July 2014, this ratio was 0.2774, indicating that this population of seals has been exposed to small quantities of Fukushima-derived radiocesium. Activity concentrations of both 134Cs and 137Cs in putchki were below detection limits, even for composited samples. Northern fur seal is known to migrate between coastal Alaska and Japan and the trace 134Cs in northern fur seal tissue suggests that the population under study had been minimally exposed Fukushima-derived radionuclides. Despite this inference, the radionuclide quantities detected are small and no impact is expected as a result of the measured radiation exposure, either in northern fur seal or human populations consuming this species.« less
Fukushima derived radiocesium in subsistence-consumed northern fur seal and wild celery.
Ruedig, Elizabeth; Duncan, Colleen; Dickerson, Bobette; Williams, Michael; Gelatt, Thomas; Bell, Justin; Johnson, Thomas E
2016-02-01
In July 2014, our investigative team traveled to St. Paul Island, Alaska to measure concentrations of radiocesium in wild-caught food products, primarily northern fur seal (Callorhinus ursinus). The 2011 Fukushima Daiichi Nuclear Power Plant accident released radiocesium into the atmosphere and into the western Pacific Ocean; other investigators have detected Fukushima-derived radionuclides in a variety of marine products harvested off the western coast of North America. We tested two subsistence-consumed food products from St. Paul Island, Alaska for Fukushima-derived radionuclides: 54 northern fur seal, and nine putchki (wild celery, Angelica lucida) plants. Individual northern fur seal samples were below minimum detectable activity concentrations of (137)Cs and (134)Cs, but when composited, northern fur seal tissues tested positive for trace quantities of both isotopes. Radiocesium was detected at an activity concentration of 37.2 mBq (134)Cs kg(-1) f.w. (95% CI: 35.9-38.5) and 141.2 mBq (137)Cs kg(-1) f.w. (95% CI: 135.5-146.8). The measured isotopic ratio, decay-corrected to the date of harvest, was 0.26 (95% CI: 0.25-0.28). The Fukushima nuclear accident released (134)Cs and (137)Cs in roughly equal quantities, but by the date of harvest in July 2014, this ratio was 0.2774, indicating that this population of seals has been exposed to small quantities of Fukushima-derived radiocesium. Activity concentrations of both (134)Cs and (137)Cs in putchki were below detection limits, even for composited samples. Northern fur seal is known to migrate between coastal Alaska and Japan and the trace (134)Cs in northern fur seal tissue suggests that the population under study had been minimally exposed Fukushima-derived radionuclides. Despite this inference, the radionuclide quantities detected are small and no impact is expected as a result of the measured radiation exposure, either in northern fur seal or human populations consuming this species. Published by Elsevier Ltd.
Steeper, Timothy J.
1989-01-01
A leak detection apparatus and method for detecting leaks across an O-ring sealing a flanged surface to a mating surface is an improvement in a flanged surface comprising a shallow groove following O-ring in communication with an entrance and exit port intersecting the shallow groove for injecting and withdrawing, respectively, a leak detection fluid, such as helium. A small quantity of helium injected into the entrance port will flow to the shallow groove, past the O-ring and to the exit port.
Nanowire Electron Scattering Spectroscopy
NASA Technical Reports Server (NTRS)
Hunt, Brian; Bronikowsky, Michael; Wong, Eric; VonAllmen, Paul; Oyafuso, Fablano
2009-01-01
Nanowire electron scattering spectroscopy (NESS) has been proposed as the basis of a class of ultra-small, ultralow-power sensors that could be used to detect and identify chemical compounds present in extremely small quantities. State-of-the-art nanowire chemical sensors have already been demonstrated to be capable of detecting a variety of compounds in femtomolar quantities. However, to date, chemically specific sensing of molecules using these sensors has required the use of chemically functionalized nanowires with receptors tailored to individual molecules of interest. While potentially effective, this functionalization requires labor-intensive treatment of many nanowires to sense a broad spectrum of molecules. In contrast, NESS would eliminate the need for chemical functionalization of nanowires and would enable the use of the same sensor to detect and identify multiple compounds. NESS is analogous to Raman spectroscopy, the main difference being that in NESS, one would utilize inelastic scattering of electrons instead of photons to determine molecular vibrational energy levels. More specifically, in NESS, one would exploit inelastic scattering of electrons by low-lying vibrational quantum states of molecules attached to a nanowire or nanotube.
Steeper, T.J.
1989-12-26
A leak detection apparatus and method for detecting leaks across an O-ring sealing a flanged surface to a mating surface is an improvement in a flanged surface comprising a shallow groove following O-ring in communication with an entrance and exit port intersecting the shallow groove for injecting and withdrawing, respectively, a leak detection fluid, such as helium. A small quantity of helium injected into the entrance port will flow to the shallow groove, past the O-ring and to the exit port. 2 figs.
NASA Astrophysics Data System (ADS)
Bronson, Frazier; Hayano, Ryugo; Oginni, Babatunde; Jaderstrom, Henrik; Ilie, Gabriela; Yamanaka, Shunji; Muramatsu, Isamu
2015-06-01
The Fukushima Dai-ichi accident has released large quantities of radionuclides, including 131I, 134Cs, and 137Cs. These radionuclides, when inhaled or ingested, cause internal dose to the individual. Whole Body Counting [WBC], also known as in-vivo counting is a common method to assess internal radioactivity as a tool to evaluate internal dose. The FastScan WBC system was widely used following the Chernobyl and the Fukushima accidents for in-vivo measurements of the population. Although the FastScan was designed for adults, it was successfully used for children by having them stand on a small stool. However small children and infants cannot stand, and have a much lower quantity of radioactive cesium. That required the development of a much more sensitive WBC system, called the BabyScan. A very important element of the project was to make the unit look esthetically pleasing, while not compromising performance. The steel shield was enclosed in a molded fiberglass exterior skin, whereas a carbon-fiber liner was used on the interior, to keep the background low. The system was calibrated using MCNP; on-site testing with phantoms confirmed the adequacy of the mathematical efficiency calibrations. The system has a Minimum Detectable Activity with a 4-min measurement of approximately 20 Bq for infants approximately 10 kg in weight, and 40 Bq for children approximately 30 kg in weight. The 40K that is naturally present is also reliably detected at the appropriate quantity for infants as small as 6 kg. Data from the first 365 subjects counted showed that 40K was detected in all of them, and that there was no 134Cs or 137Cs above the MDA levels.
USDA-ARS?s Scientific Manuscript database
Honey mesquite (Prosopis glandulosa Torr.) is a common invasive shrub whose leaves contain secondary compounds that limit consumption by cattle. However, crude protein and fiber levels of mesquite leaves are similar to alfalfa hay. The ability to consume small quantities of mesquite leaves might mak...
ERIC Educational Resources Information Center
Behrman, E. J.; Gopalan, Venkat
2005-01-01
There is a widespread belief among the public and even among chemist that plants do not contain cholesterol. This wrong belief is the result of the fact that plants generally contain only small quantities of cholesterol and that analytical methods for the detection of cholesterol in this range were not developed until recently.
Continuous Thermometric Apparatus for Carbon Monoxide Detection
1943-08-30
small cell containing Hopcalite , and a stream of air(1.5 li- ters per minute) passes; through the catalyst and around the ther- mometer bulb. The...from the heat of oxidation on the Hopcalite of selected concentrations of carbon monoxide. Thus in one thermometer used the base temperature was...in air. The air was drawn through a small quantity of Hopcalite , on which the carbon monoxide was oxidized, and the rise in temperature resulting
NASA Astrophysics Data System (ADS)
White, Ian M.; Oveys, Hesam; Fan, Xudong
2006-02-01
Optical microsphere resonators can function as highly sensitive bio/chemical sensors due to the large Q-factor, which leads to high light-matter interaction. The whispering gallery modes (WGM) arise at the surface of the microsphere, creating a highly enhanced optical field that interacts with matter on or near the microsphere surface. As a result, the spectral position of the WGM is extremely sensitive to refractive index changes near the surface, such as when bio/chemical molecules bind to the sphere. We show the potential feasibility of a microsphere ring resonator as a sensor for small molecules by demonstrating detection of sub-femtomole changes in SiO II molecules at the surface of the microsphere. In this experiment, the silica molecules act as an excellent model for small molecule analytes because of their 60 Dalton molecular weight, and because we know nearly the exact quantity of molecules at the surface, which enables a sensitivity characterization. We measure the spectral shifts in the WGMs when low concentrations of hydrofluoric acid (HF) are added to a solution that is being probed by the microsphere. As the HF molecules break apart the SiO II molecules at the sphere surface, the WGMs shift due to the sub-nano-scale decrease in the size of the microsphere. These calculations show that the sensitivity of this microsphere resonator is on the order of 500 attomoles. Our results will lead to the utilization of optical microspheres for detection of trace quantities of small molecules for such applications as drug discovery, environmental monitoring, and enzyme detection using peptide cleavage.
A Simple and Inexpensive Capillary Holder for Thin-Layer Chromatography
ERIC Educational Resources Information Center
Pintea, Beniamin-Nicolae V.
2011-01-01
Thin-layer chromatography (TLC) is a widely used method of qualitative analysis in organic synthesis, as it uniquely combines low cost, rapidity, simplicity, versatility, small quantities of sample and low detection limits. The simplest and most economical method for the application of samples onto TLC plates is by hand, using glass capillaries.…
Ganesan, K.; Raza, S. K.; Vijayaraghavan, R.
2010-01-01
Among the Weapons of Mass Destruction, chemical warfare (CW) is probably one of the most brutal created by mankind in comparison with biological and nuclear warfare. Chemical weapons are inexpensive and are relatively easy to produce, even by small terrorist groups, to create mass casualties with small quantities. The characteristics of various CW agents, general information relevant to current physical as well as medical protection methods, detection equipment available and decontamination techniques are discussed in this review article. A brief note on Chemical Weapons Convention is also provided. PMID:21829312
Development of marijuana and tobacco detectors using potassium-40 gamma-ray emissions
NASA Astrophysics Data System (ADS)
Kirby, John A.; Lindquist, Roy P.
1994-10-01
Measurements were made at the Otay Mesa, CA, border crossing between November 30 and December 4, 1992, to demonstrate proof of concept and the practicality of using potassium 40 (K40) gamma emissions to detect the presence of marijuana in vehicles. Lawrence Livermore National Laboratory personnel, with the assistance of the EPA, set up three large volume gamma ray detectors with lead brick shielding and collimation under a stationary trailer and pickup truck. Measurements were performed for various positions and quantities of marijuana. Also, small quantities of marijuana, cigarettes, and other materials were subjected to gamma counting measurements under controlled geometry conditions to determine their K40 concentration. Larger quantities of heroin and cocaine were subjected to undefined geometry gamma counts for significant K40 gamma emissions.
A new method for detecting small and dim targets in starry background
NASA Astrophysics Data System (ADS)
Yao, Rui; Zhang, Yanning; Jiang, Lei
2011-08-01
Small visible optical space targets detection is one of the key issues in the research of long-range early warning and space debris surveillance. The SNR(Signal to Noise Ratio) of the target is very low because of the self influence of image device. Random noise and background movement also increase the difficulty of target detection. In order to detect small visible optical space targets effectively and rapidly, we bring up a novel detecting method based on statistic theory. Firstly, we get a reasonable statistical model of visible optical space image. Secondly, we extract SIFT(Scale-Invariant Feature Transform) feature of the image frames, and calculate the transform relationship, then use the transform relationship to compensate whole visual field's movement. Thirdly, the influence of star was wiped off by using interframe difference method. We find segmentation threshold to differentiate candidate targets and noise by using OTSU method. Finally, we calculate statistical quantity to judge whether there is the target for every pixel position in the image. Theory analysis shows the relationship of false alarm probability and detection probability at different SNR. The experiment result shows that this method could detect target efficiently, even the target passing through stars.
High efficiency direct detection of ions from resonance ionization of sputtered atoms
Gruen, Dieter M.; Pellin, Michael J.; Young, Charles E.
1986-01-01
A method and apparatus are provided for trace and other quantitative analysis with high efficiency of a component in a sample, with the analysis involving the removal by ion or other bombardment of a small quantity of ion and neutral atom groups from the sample, the conversion of selected neutral atom groups to photoions by laser initiated resonance ionization spectroscopy, the selective deflection of the photoions for separation from original ion group emanating from the sample, and the detection of the photoions as a measure of the quantity of the component. In some embodiments, the original ion group is accelerated prior to the RIS step for separation purposes. Noise and other interference are reduced by shielding the detector from primary and secondary ions and deflecting the photoions sufficiently to avoid the primary and secondary ions.
High efficiency direct detection of ions from resonance ionization of sputtered atoms
Gruen, D.M.; Pellin, M.J.; Young, C.E.
1985-01-16
A method and apparatus are provided for trace and other quantitative analysis with high efficiency of a component in a sample, with the analysis involving the removal by ion or other bombardment of a small quantity of ion and neutral atom groups from the sample, the conversion of selected neutral atom groups to photoions by laser initiated resonance ionization spectroscopy, the selective deflection of the photoions for separation from original ion group emanating from the sample, and the detection of the photoions as a measure of the quantity of the component. In some embodiments, the original ion group is accelerated prior to the RIS step for separation purposes. Noise and other interference are reduced by shielding the detector from primary and secondary ions and deflecting the photoions sufficiently to avoid the primary and secondary ions.
NASA Astrophysics Data System (ADS)
Tartaglione, A.; Di Lorenzo, F.; Mayer, R. E.
2009-07-01
Cargo interrogation in search for special nuclear materials like highly-enriched uranium or 239Pu is a first priority issue of international borders security. In this work we present a thermal-pulsed neutron-based approach to a technique which combines the time-of-flight method and demonstrates a capability to detect small quantities of highly-enriched uranium shielded with high or low Z materials providing, in addition, a manner to know the approximate position of the searched material.
Analysis of limette and bergamot distilled essential oils by HPLC.
Buiarelli, Francesca; Cartoni, Giampaolo; Coccioli, Franco; Jasionowska, Renata; Mazzarino, Monica
2002-04-01
This work examines the distilled essential oils of limette and bergamot in order to assess the presence of low volatile substances such as coumarins (bergapten) which, being toxic, must be eliminated before using these oils in the food industry. The quantitative determination of coumarins was carried out by spectrofluorimetric detection. The substances present in the chromatograms, obtained by HPLC with UV detection at 254 nm, were then identified. Moreover, a new coumarin that is present in small quantities was identified using HPLC-MS.
Polley, Spencer D.; Mori, Yasuyoshi; Watson, Julie; Perkins, Mark D.; González, Iveth J.; Notomi, Tsugunori; Chiodini, Peter L.; Sutherland, Colin J.
2010-01-01
Loop-mediated isothermal amplification (LAMP) of DNA offers the ability to detect very small quantities of pathogen DNA following minimal tissue sample processing and is thus an attractive methodology for point-of-care diagnostics. Previous attempts to diagnose malaria by the use of blood samples and LAMP have targeted the parasite small-subunit rRNA gene, with a resultant sensitivity for Plasmodium falciparum of around 100 parasites per μl. Here we describe the use of mitochondrial targets for LAMP-based detection of any Plasmodium genus parasite and of P. falciparum specifically. These new targets allow routine amplification from samples containing as few as five parasites per μl of blood. Amplification is complete within 30 to 40 min and is assessed by real-time turbidimetry, thereby offering rapid diagnosis with greater sensitivity than is achieved by the most skilled microscopist or antigen detection using lateral flow immunoassays. PMID:20554824
10 CFR 40.22 - Small quantities of source material.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Small quantities of source material. 40.22 Section 40.22 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF SOURCE MATERIAL General Licenses § 40.22 Small quantities of source material. (a) A general license is hereby issued authorizing commercial and industrial...
Development of marijuana and tobacco detectors using potassium-40 gamma ray emissions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirby, J.; Lindquist, R.P.
Measurements were made at the Otay Mesa, Ca. border crossing between November 30 and December 4, 1992 to demonstrate proof of concept and the practicality of using potassium 40 (K40) gamma emissions to detect the presence of marijuana in vehicles. Lawrence Livermore National Laboratory (LLNL) personnel, with the assistance of the EPA, set up three large volume gamma ray detectors with lead brick shielding and collimation under a stationary trailer and pickup truck. Measurements were performed for various positions and quantities of marijuana. Also, small quantities of marijuana, cigarettes, and other materials were subjected to gamma counting measurements under controlledmore » geometry conditions to determine their K40 concentration. Larger quantities of heroin and cocaine were subjected to undefined geometry gamma counts for significant K40 gamma emissions.« less
Clinical Utility of Circulating Tumor Cells in ALK-Positive Non-Small-Cell Lung Cancer.
Faugeroux, Vincent; Pailler, Emma; Auger, Nathalie; Taylor, Melissa; Farace, Françoise
2014-01-01
The advent of rationally targeted therapies such as small-molecule tyrosine kinase inhibitors (TKIs) has considerably transformed the therapeutic management of a subset of patients with non-small-cell lung cancer (NSCLC) harboring defined molecular abnormalities. When such genetic molecular alterations are detected the use of specific TKI has demonstrated better results (overall response rate, progression free survival) compared to systemic therapy. However, the detection of such molecular abnormalities is complicated by the difficulty in obtaining sufficient tumor material, in terms of quantity and quality, from a biopsy. Here, we described how circulating tumor cells (CTCs) can have a clinical utility in anaplastic lymphoma kinase (ALK) positive NSCLC patients to diagnose ALK-EML4 gene rearrangement and to guide therapeutic management of these patients. The ability to detect genetic abnormalities such ALK rearrangement in CTCs shows that these cells could offer new perspectives both for the diagnosis and the monitoring of ALK-positive patients eligible for treatment with ALK inhibitors.
Clinical Utility of Circulating Tumor Cells in ALK-Positive Non-Small-Cell Lung Cancer
Faugeroux, Vincent; Pailler, Emma; Auger, Nathalie; Taylor, Melissa; Farace, Françoise
2014-01-01
The advent of rationally targeted therapies such as small-molecule tyrosine kinase inhibitors (TKIs) has considerably transformed the therapeutic management of a subset of patients with non-small-cell lung cancer (NSCLC) harboring defined molecular abnormalities. When such genetic molecular alterations are detected the use of specific TKI has demonstrated better results (overall response rate, progression free survival) compared to systemic therapy. However, the detection of such molecular abnormalities is complicated by the difficulty in obtaining sufficient tumor material, in terms of quantity and quality, from a biopsy. Here, we described how circulating tumor cells (CTCs) can have a clinical utility in anaplastic lymphoma kinase (ALK) positive NSCLC patients to diagnose ALK-EML4 gene rearrangement and to guide therapeutic management of these patients. The ability to detect genetic abnormalities such ALK rearrangement in CTCs shows that these cells could offer new perspectives both for the diagnosis and the monitoring of ALK-positive patients eligible for treatment with ALK inhibitors. PMID:25414829
USDA-ARS?s Scientific Manuscript database
To detect the effects of a rye cover crop on labile soil carbon, the light fraction, large particulate organic matter (POM), small POM, and two NaOH-extractable humic fractions were extracted from three depths of a corn soil in central Iowa having an overwinter rye cover crop treatment and a contro...
Hofman, Paul
2017-01-01
Patients with advanced-stage non-small cell lung carcinoma (NSCLC) harboring an ALK rearrangement, detected from a tissue sample, can benefit from targeted ALK inhibitor treatment. Several increasingly effective ALK inhibitors are now available for treatment of patients. However, despite an initial favorable response to treatment, in most cases relapse or progression occurs due to resistance mechanisms mainly caused by mutations in the tyrosine kinase domain of ALK. The detection of an ALK rearrangement is pivotal and can be done using different methods, which have variable sensitivity and specificity depending, in particular, on the quality and quantity of the patient’s sample. This review will first highlight briefly some information regarding the pathobiology of an ALK rearrangement and the epidemiology of patients harboring this genomic alteration. The different methods used to detect an ALK rearrangement as well as their advantages and disadvantages will then be examined and algorithms proposed for detection in daily routine practice. PMID:28805682
Detection and persistence of environmental DNA from an invasive, terrestrial mammal.
Williams, Kelly E; Huyvaert, Kathryn P; Vercauteren, Kurt C; Davis, Amy J; Piaggio, Antoinette J
2018-01-01
Invasive Sus scrofa , a species commonly referred to as wild pig or feral swine, is a destructive invasive species with a rapidly expanding distribution across the United States. We used artificial wallows and small waterers to determine the minimum amount of time needed for pig eDNA to accumulate in the water source to a detectable level. We removed water from the artificial wallows and tested eDNA detection over the course of 2 weeks to understand eDNA persistence. We show that our method is sensitive enough to detect very low quantities of eDNA shed by a terrestrial mammal that has limited interaction with water. Our experiments suggest that the number of individuals shedding into a water system can affect persistence of eDNA. Use of an eDNA detection technique can benefit management efforts by providing a sensitive method for finding even small numbers of individuals that may be elusive using other methods.
Hofman, Paul
2017-08-12
Patients with advanced-stage non-small cell lung carcinoma (NSCLC) harboring an ALK rearrangement, detected from a tissue sample, can benefit from targeted ALK inhibitor treatment. Several increasingly effective ALK inhibitors are now available for treatment of patients. However, despite an initial favorable response to treatment, in most cases relapse or progression occurs due to resistance mechanisms mainly caused by mutations in the tyrosine kinase domain of ALK. The detection of an ALK rearrangement is pivotal and can be done using different methods, which have variable sensitivity and specificity depending, in particular, on the quality and quantity of the patient's sample. This review will first highlight briefly some information regarding the pathobiology of an ALK rearrangement and the epidemiology of patients harboring this genomic alteration. The different methods used to detect an ALK rearrangement as well as their advantages and disadvantages will then be examined and algorithms proposed for detection in daily routine practice.
Geology and occurrence of ground water in Lyon County, Minnesota
Rodis, Harry G.
1963-01-01
Large quantities of ground water are available from melt-water channels in the county. Moderate quantities, adequate for domestic and small industrial needs, are available from many of the small isolated deposits of sand and gravel in the till. Small quantities of ground water, adequate only for domestic supply, generally can be obtained from Cretaceous sandstone.
A small quantity of sodium arsenite will kill large cull hardwoods
Francis M. Rushmore
1956-01-01
Although it is well known that sodium arsenite is an effective silvicide, forestry literature contains little information about the minimum quantities of this chemical that are required to kill large cull trees. Such information would be of value because if small quantities of a chemical will produce satisfactory results, small holes or frills in the tree will hold it...
Chemical Characterization of the Pyrotechnically Disseminated KM03 Red Phosphorus Floating Smoke Pot
2006-05-01
concentrations. Some of the other compounds observed were sulfur dioxide, hexamethylcyclotrisiloxane, xylene, octamethylcyclotetrasiloxane, dl- limonene ...for the complete analysis of the VOC’s collected. Limonene , xylene, and sulfur dioxide were also detected in small quantities during the...disseminations. Usually, limonene occurs naturally in trees, bushes, and/or citrus oils, but its reason for its presence in the characterized smoke is unclear
Mauchline, T H; Mohan, S; Davies, K G; Schaff, J E; Opperman, C H; Kerry, B R; Hirsch, P R
2010-05-01
To establish a reliable protocol to extract DNA from Pasteuria penetrans endospores for use as template in multiple strand amplification, thus providing sufficient material for genetic analyses. To develop a highly sensitive PCR-based diagnostic tool for P. penetrans. An optimized method to decontaminate endospores, release and purify DNA enabled multiple strand amplification. DNA purity was assessed by cloning and sequencing gyrB and 16S rRNA gene fragments obtained from PCR using generic primers. Samples indicated to be 100%P. penetrans by the gyrB assay were estimated at 46% using the 16S rRNA gene. No bias was detected on cloning and sequencing 12 housekeeping and sporulation gene fragments from amplified DNA. The detection limit by PCR with Pasteuria-specific 16S rRNA gene primers following multiple strand amplification of DNA extracted using the method was a single endospore. Generation of large quantities DNA will facilitate genomic sequencing of P. penetrans. Apparent differences in sample purity are explained by variations in 16S rRNA gene copy number in Eubacteria leading to exaggerated estimations of sample contamination. Detection of single endospores will facilitate investigations of P. penetrans molecular ecology. These methods will advance studies on P. penetrans and facilitate research on other obligate and fastidious micro-organisms where it is currently impractical to obtain DNA in sufficient quantity and quality.
Imaging of blood antigen distribution on blood cells by thermal lens microscopy
NASA Astrophysics Data System (ADS)
Kimura, Hiroko; Sekiguchi, Kazuya; Nagao, Fumiko; Mukaida, Masahiro; Kitamori, Takehiko; Sawada, Tsuguo
2000-05-01
Blood group antigens on a cell were measured by a new microscopic method, i.e. thermal lens microscopy which involves spectrometry using a laser-induced thermal-lens effect. The blood group antigen was immunologically stained using antibody labeled with colloidal gold. Human leukocyte antigens (HLA) on lymphocytes and mononuclear leukocytes were observed by the thermal lens microscope, and Lewis blood group antigens on erythrocytes and polymorphonuclear leukocytes were also observed. The antigen distribution on each cell-surface was imaged using this technique. In spite of convex surface of living cells, colloidal gold was correctly quantified by adjusting the deviation of the focal point of the probe laser by the phase of the signal. In the measurement of leukocyte antigens, antigens of HLA-A, -B, -C loci on the lymphocytes were identified and quantitated by using a single cell. The image of HLA-A, -B, -C antigen distribution on a mononuclear leukocyte was obtained. In the measurement of erythrocyte antigens, a small quantity of Lewis antigens was detected on the cord erythrocytes. Localized small quantities of membrane antigens are better quantitated without extraction or cytolysis. Our thermal lens microscope is a powerful and highly sensitive analytical tool for detecting and quantitating localized antigens in single cells and/or cell-surface-associated molecules.
Design of an integrated sensor system for the detection of traces of different molecules in the air
NASA Astrophysics Data System (ADS)
Strle, D.; Muševič, I.
2015-04-01
This article presents the design of a miniature detection system and its associated signal processing electronics, which can detect and selectively recognize vapor traces of different materials in the air - including explosives. It is based on the array of surface-functionalized COMB capacitive sensors and extremely low noise, analog, integrated electronic circuit, hardwired digital signal processing hardware and additional software running on a PC. The instrument is sensitive and selective, consumes a minimum amount of energy, is very small (few mm3) and cheap to produce in large quantities, and is insensitive to mechanical influences. Using an electronic detection system built of low noise analog front-end and hard-wired digital signal processing, it is possible to detect less than 0.3ppt of TNT molecules in the atmosphere (3 TNT molecules in 1013 molecules of the air) at 25°C on a 1 Hz bandwidth using very small volume and approx. 10 mA current from a 5V supply voltage. The sensors are implemented in a modified MEMS process and analog electronics in 0.18 um CMOS technology.
An Artesunate-Containing Antimalarial Treatment Regimen Did Not Suppress Cytomegalovirus Viremia
Gantt, Soren; Huang, Meei-Li; Magaret, Amalia; Bunts, Lisa; Selke, Stacy; Wald, Anna; Rosenthal, Philip J.; Dorsey, Grant; Casper, Corey
2014-01-01
Background Additional drugs are needed for the treatment of cytomegalovirus (CMV) infection. Artesunate is an antimalarial drug that has activity against CMV in vitro and in a rodent model. Only a small number of case reports are available describing the clinical effects of artesunate on CMV infection, and these yielded inconsistent results. Objective To evaluate the effect of artesunate on CMV infection, using blood samples collected from children who participated in malaria treatment trials. Study design Quantitative CMV DNA PCR was performed on dried blood spots collected from 494 Ugandan children, who were randomized either to artesunate plus amodiaquine or sulfadoxine-pyrimethamine plus amodiaquine for acute malaria infection. Poisson regression was used to compare treatment regimens with respect to the change in the frequency and quantity of CMV detected that occurred before and after treatment. Results CMV was detected in 11.4% of children immediately prior to treatment and 10.7% 3 days later (p=0.70). The average quantity of CMV was 0.30 log10 copies per million cells higher on day 3 than at treatment initiation (95% CI 0.01 to 0.58, p=0.041). There was no measurable difference in either the frequency or quantity of CMV detected in blood between children randomized to the two treatment arms. Conclusions A standard 3-day artesunate-containing antimalarial regimen had no detectable effect on CMV viremia in children with malaria. Longer treatment courses and/or higher doses of artesunate than those routinely used for malaria may be required for effective treatment of CMV infection. PMID:23827788
Kitt, Jay P; Harris, Joel M
2015-05-19
Octanol-water partitioning is one of the most widely used predictors of hydrophobicity and lipophilicity. Traditional methods for measuring octanol-water partition coefficients (K(ow)), including shake-flasks and generator columns, require hours for equilibration and milliliter quantities of sample solution. These challenges have led to development of smaller-scale methods for measuring K(ow). Recent advances in microfluidics have produced faster and smaller-volume approaches to measuring K(ow). As flowing volumes are reduced, however, separation of water and octanol prior to measurement and detection in small volumes of octanol phase are especially challenging. In this work, we reduce the receiver volume of octanol-water partitioning measurements from current practice by six-orders-of-magnitude, to the femtoliter scale, by using a single octanol-filled reversed-phase, octadecylsilane-modified (C18-silica) chromatographic particle as a collector. The fluid-handling challenges of working in such small volumes are circumvented by eliminating postequilibration phase separation. Partitioning is measured in situ within the pore-confined octanol phase using confocal Raman microscopy, which is capable of detecting and quantifying a wide variety of molecular structures. Equilibration times are fast (less than a minute) because molecular diffusion is efficient over distance scales of micrometers. The demonstrated amount of analyte needed to carry out a measurement is very small, less than 50 fmol, which would be a useful attribute for drug screening applications or testing of small quantities of environmentally sensitive compounds. The method is tested for measurements of pH-dependent octanol-water partitioning of naphthoic acid, and the results are compared to both traditional shake-flask measurements and sorption onto C18-modified silica without octanol present within the pores.
Biochip-Based Detection of KRAS Mutation in Non-Small Cell Lung Cancer
Kriegshäuser, Gernot; Fabjani, Gerhild; Ziegler, Barbara; Zöchbauer-Müller, Sabine; End, Adelheid; Zeillinger, Robert
2011-01-01
This study is aimed at evaluating the potential of a biochip assay to sensitively detect KRAS mutation in DNA from non-small cell lung cancer (NSCLC) tissue samples. The assay covers 10 mutations in codons 12 and 13 of the KRAS gene, and is based on mutant-enriched PCR followed by reverse-hybridization of biotinylated amplification products to an array of sequence-specific probes immobilized on the tip of a rectangular plastic stick (biochip). Biochip hybridization identified 17 (21%) samples to carry a KRAS mutation of which 16 (33%) were adenocarcinomas and 1 (3%) was a squamous cell carcinoma. All mutations were confirmed by DNA sequencing. Using 10 ng of starting DNA, the biochip assay demonstrated a detection limit of 1% mutant sequence in a background of wild-type DNA. Our results suggest that the biochip assay is a sensitive alternative to protocols currently in use for KRAS mutation testing on limited quantity samples. PMID:22272089
Hu, Erzhong; Nosato, Hirokazu; Sakanashi, Hidenori; Murakawa, Masahiro
2013-01-01
Capsule endoscopy is a patient-friendly endoscopy broadly utilized in gastrointestinal examination. However, the efficacy of diagnosis is restricted by the large quantity of images. This paper presents a modified anomaly detection method, by which both known and unknown anomalies in capsule endoscopy images of small intestine are expected to be detected. To achieve this goal, this paper introduces feature extraction using a non-linear color conversion and Higher-order Local Auto Correlation (HLAC) Features, and makes use of image partition and subspace method for anomaly detection. Experiments are implemented among several major anomalies with combinations of proposed techniques. As the result, the proposed method achieved 91.7% and 100% detection accuracy for swelling and bleeding respectively, so that the effectiveness of proposed method is demonstrated.
Detection and quantification of intraperitoneal fluid using electrical impedance tomography.
Sadleir, R J; Fox, R A
2001-04-01
A prototype electrical impedance tomography system was evaluated prior to its use for the detection of intraperitoneal bleeding, with the assistance of patients undergoing continuous ambulatory peritoneal dialysis (CAPD). The system was sensitive enough to detect small amounts of dialysis fluid appearing in subtractive images over short time periods. Uniform sensitivity to blood appearing anywhere within the abdominal cavity was produced using a post-reconstructive filter that corrected for changes in apparent resistivity of anomalies with their radial position. The image parameter used as an indication of fluid quantity, the resistivity index, varied approximately linearly with the quantity of fluid added. A test of the system's response to the introduction of conductive fluid out of the electrode plane (when a blood-equivalent fluid was added to the stomach) found that the sensitivity of the system was about half that observed in the electrode plane. Breathing artifacts were found to upset quantitative monitoring of intraperitoneal bleeding, but only on time scales short compared with the fluid administration rate. Longer term breathing changes, such as those due to variations in the functional residual capacity of the lungs, should ultimately limit the sensitivity over long time periods.
10 CFR 40.22 - Small quantities of source material.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Small quantities of source material. 40.22 Section 40.22 Energy NUCLEAR REGULATORY COMMISSION DOMESTIC LICENSING OF SOURCE MATERIAL General Licenses § 40.22 Small... (15.4 lb) of uranium, removed during the treatment of drinking water, at any one time. A person may...
NASA Astrophysics Data System (ADS)
Mohri, K.; Takeuchi, S.
1982-11-01
New sensitive magnetic-field sensors are presented using twisted amorphous magnetostrictive ribbons such as Fe80B20 and Fe81-xCrxB17Si2. Sharp voltage pulses are induced between ends of the ribbon of as short as 25 mm or at the terminals of the detecting coil against external fields of as low as 1 Oe and 0.01 Hz-6 kHz. The domain nucleation field at the bistable flux reversal is very constant for 130 °C, 600 h using Fe79Cr2B17Si2, and a possible maximum operating temperature is about 180 °C. Small sized magnetic sensors without any windings for detecting rotational speed, distance, and other mechanical quantities are realized using the twisted ribbons by combining with small magnets. These sensitive and reliable magnetic sensors with digital outputs are suitable for applications in industrial robots and automobiles controlled with microcomputers.
Rapid polymerase chain reaction diagnosis of white-nose syndrome in bats
Lorch, J.M.; Gargas, A.; Meteyer, C.U.; Berlowski-Zier, B. M.; Green, D.E.; Shearn-Bochsler, V.; Thomas, N.J.; Blehert, D.S.
2010-01-01
A newly developed polymerase chain reaction (PCR)-based method to rapidly and specifically detect Geomyces destructans on the wings of infected bats from small quantities (1-2 mg) of tissue is described in the current study (methods for culturing and isolating G. destructans from bat skin are also described). The lower limits of detection for PCR were 5 fg of purified fungal DNA or 100 conidia per 2 mg of wing tissue. By using histology as the standard, the PCR had a diagnostic specificity of 100% and a diagnostic sensitivity of 96%, whereas the diagnostic sensitivity of culture techniques was only 54%. The accuracy and fast turnaround time of PCR provides field biologists with valuable information on infection status more rapidly than traditional methods, and the small amount of tissue required for the test would allow diagnosis of white-nose syndrome in live animals.
MANAGEMENT OF HOUSEHOLD AND SMALL-QUANTITY-GENERATOR HAZARDOUS WASTE IN THE UNITED STATES
The International Solid Waste and Public Cleansing Association (ISWA), an international nongovernmental organization comprising twenty-seven national organizations of waste management professionals, conducted a survey to obtain information regarding household and small-quantity-g...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kluge, T., E-mail: t.kluge@hzdr.de; Bussmann, M.; Huang, L. G., E-mail: lingen.huang@hzdr.de
Here, we propose to exploit the low energy bandwidth, small wavelength, and penetration power of ultrashort pulses from XFELs for resonant Small Angle Scattering (SAXS) on plasma structures in laser excited plasmas. Small angle scattering allows to detect nanoscale density fluctuations in forward scattering direction. Typically, the SAXS signal from laser excited plasmas is expected to be dominated by the free electron distribution. We propose that the ionic scattering signal becomes visible when the X-ray energy is in resonance with an electron transition between two bound states (resonant coherent X-ray diffraction). In this case, the scattering cross-section dramatically increases somore » that the signal of X-ray scattering from ions silhouettes against the free electron scattering background which allows to measure the opacity and derived quantities with high spatial and temporal resolution, being fundamentally limited only by the X-ray wavelength and timing. Deriving quantities such as ion spatial distribution, charge state distribution, and plasma temperature with such high spatial and temporal resolution will make a vast number of processes in shortpulse laser-solid interaction accessible for direct experimental observation, e.g., hole-boring and shock propagation, filamentation and instability dynamics, electron transport, heating, and ultrafast ionization dynamics.« less
NUTS and BOLTS: Applications of Fluorescence Detected Sedimentation
Kroe, Rachel R.; Laue, Thomas M.
2008-01-01
Analytical ultracentrifugation is a widely used method for characterizing the solution behavior of macromolecules. However, the two commonly used detectors (absorbance and interference) impose some fundamental restrictions on the concentrations and complexity of the solutions that can be analyzed. The recent addition of a fluorescence detector for the XL-I analytical ultracentrifuge (AU-FDS) enables two different types of sedimentation experiments. First, the AU-FDS can detect picomolar concentrations of labeled solutes allowing the characterization of very dilute solutions of macromolecules, applications we call Normal Use Tracer Sedimentation (NUTS). The great sensitivity of NUTS analysis allows the characterization of small quantities of materials and high affinity interactions. Second, AU-FDS allows characterization of trace quantities of labeled molecules in solutions containing high concentrations and complex mixtures of unlabeled molecules, applications we call Biological On Line Tracer Sedimentation (BOLTS). The discrimination of BOLTS enables the size distribution of a labeled macromolecule to be determined in biological milieu such as cell lysates and serum. Examples are presented that embody features of both NUTS and BOLTS applications, along with our observations on these applications. PMID:19103145
NASA Technical Reports Server (NTRS)
2004-01-01
A revolutionary, low-calorie sugar is now available to the food and beverage market, offering an all-natural alternative to table sugar and artificial sweeteners. Tagatose, a sugar that appears in nature in small quantities, began its unusual journey to the commercial market nearly 30 years ago, when Dr. Gilbert V. Levin invented a life detection experiment to place aboard NASA s Mars Viking 1 and Viking 2 landers. The experiment involved using radiation-laced nutrients to determine the presence of microbial life in Martian soil samples.
Doherty, Brenda; Csáki, Andrea; Thiele, Matthias; Zeisberger, Matthias; Schwuchow, Anka; Kobelke, Jens; Fritzsche, Wolfgang; Schmidt, Markus A
2017-02-01
Detecting small quantities of specific target molecules is of major importance within bioanalytics for efficient disease diagnostics. One promising sensing approach relies on combining plasmonically-active waveguides with microfluidics yielding an easy-to-use sensing platform. Here we introduce suspended-core fibres containing immobilised plasmonic nanoparticles surrounding the guiding core as a concept for an entirely integrated optofluidic platform for efficient refractive index sensing. Due to the extremely small optical core and the large adjacent microfluidic channels, over two orders of magnitude of nanoparticle coverage densities have been accessed with millimetre-long sample lengths showing refractive index sensitivities of 170 nm/RIU for aqueous analytes where the fibre interior is functionalised by gold nanospheres. Our concept represents a fully integrated optofluidic sensing system demanding small sample volumes and allowing for real-time analyte monitoring, both of which are highly relevant within invasive bioanalytics, particularly within molecular disease diagnostics and environmental science.
40 CFR 273.17 - Response to releases.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 273.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste § 273.17... of universal wastes and other residues from universal wastes. (b) A small quantity handler of...
40 CFR 273.18 - Off-site shipments.
Code of Federal Regulations, 2011 CFR
2011-07-01
....18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste § 273.18 Off-site shipments. (a) A small quantity handler of universal waste is prohibited from sending or...
40 CFR 273.18 - Off-site shipments.
Code of Federal Regulations, 2012 CFR
2012-07-01
....18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste § 273.18 Off-site shipments. (a) A small quantity handler of universal waste is prohibited from sending or...
40 CFR 273.18 - Off-site shipments.
Code of Federal Regulations, 2010 CFR
2010-07-01
....18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste § 273.18 Off-site shipments. (a) A small quantity handler of universal waste is prohibited from sending or...
40 CFR 273.18 - Off-site shipments.
Code of Federal Regulations, 2014 CFR
2014-07-01
....18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste § 273.18 Off-site shipments. (a) A small quantity handler of universal waste is prohibited from sending or...
40 CFR 273.18 - Off-site shipments.
Code of Federal Regulations, 2013 CFR
2013-07-01
....18 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste § 273.18 Off-site shipments. (a) A small quantity handler of universal waste is prohibited from sending or...
1974-01-01
A survey of 763 patients with rheumatoid arthritis and 145 with osteoarthritis in six clinics in New Zealand showed no association between aspirin intake and a score designed to detect analgesic nephropathy. Analgesic nephropathy was diagnosed clinically in three patients taking APC (aspirin, phenacetin, and caffeine or codeine or both) and in one who took aspirin and phenylbutazone and was suspected in one who took aspirin and paracetamol. Isolated aspirin was not implicated. The study showed that most people can take large quantities of salicylates without renal injury. The findings are, however, consistent with the view that there is a risk from APC compounds taken in large quantity, but the numbers at risk in this study were small. Aspirin may have an additive effect with other analgesics in causing renal damage. An increased frequency of urinary tract symptoms in those taking analgesics requires further investigation. PMID:4821007
A Maximum Entropy Test for Evaluating Higher-Order Correlations in Spike Counts
Onken, Arno; Dragoi, Valentin; Obermayer, Klaus
2012-01-01
Evaluating the importance of higher-order correlations of neural spike counts has been notoriously hard. A large number of samples are typically required in order to estimate higher-order correlations and resulting information theoretic quantities. In typical electrophysiology data sets with many experimental conditions, however, the number of samples in each condition is rather small. Here we describe a method that allows to quantify evidence for higher-order correlations in exactly these cases. We construct a family of reference distributions: maximum entropy distributions, which are constrained only by marginals and by linear correlations as quantified by the Pearson correlation coefficient. We devise a Monte Carlo goodness-of-fit test, which tests - for a given divergence measure of interest - whether the experimental data lead to the rejection of the null hypothesis that it was generated by one of the reference distributions. Applying our test to artificial data shows that the effects of higher-order correlations on these divergence measures can be detected even when the number of samples is small. Subsequently, we apply our method to spike count data which were recorded with multielectrode arrays from the primary visual cortex of anesthetized cat during an adaptation experiment. Using mutual information as a divergence measure we find that there are spike count bin sizes at which the maximum entropy hypothesis can be rejected for a substantial number of neuronal pairs. These results demonstrate that higher-order correlations can matter when estimating information theoretic quantities in V1. They also show that our test is able to detect their presence in typical in-vivo data sets, where the number of samples is too small to estimate higher-order correlations directly. PMID:22685392
Brunborg, Geir Scott; Østhus, Ståle
2015-02-01
We investigated if increased drinking frequency among adults in the second half of life co-occurred with increased usual quantity and increased intoxication frequency. Two-wave panel study. Norway. Norwegian adults (1017 women and 959 men) aged 40-79 years. Drinking frequency, usual quantity and intoxication frequency was measured by self-report in 2002/03 and again in 2007/08. Information about gender, age and level of education was obtained from the public register. Health was collected by self-report. Because of a significant gender × change in drinking frequency interaction effect on change in intoxication frequency (b = 0.02, P = 0.013), women and men were analysed separately. After adjusting for covariates, women who increase their drinking frequency showed a non-significant decrease in usual quantity [low initial usual quantity (LIUQ): β = -0.01, P = 0.879; high initial usual quantity (HIUQ): β = -0.06, P = 0.164] and a non-significant increase in intoxication frequency (LIUQ: β = 0.04, P = 0.569; HIUQ: β = 0.09, P = 0.251). Men who increased their drinking frequency showed a small decrease in usual quantity (LIUQ: β = -0.06, P = 0.049; HIUQ: β = -0.05, P = 0.002) and a small increase in intoxication frequency (LIUQ: β = 0.05, P = 0.035; HIUQ: β = 0.13, P = 0.004). Among Norwegian adults in the second half of life, increased drinking frequency appears to be associated with a small reduction in usual quantity, and a small increase in frequency of drinking to intoxication. © 2014 Society for the Study of Addiction.
High resolution gas volume change sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dirckx, Joris J. J.; Aernouts, Jef E. F.; Aerts, Johan R. M.
2007-05-15
Changes of gas quantity in a system can be measured either by measuring pressure changes or by measuring volume changes. As sensitive pressure sensors are readily available, pressure change is the commonly used technique. In many physiologic systems, however, buildup of pressure influences the gas exchange mechanisms, thus changing the gas quantity change rate. If one wants to study the gas flow in or out of a biological gas pocket, measurements need to be done at constant pressure. In this article we present a highly sensitive sensor for quantitative measurements of gas volume change at constant pressure. The sensor ismore » based on optical detection of the movement of a droplet of fluid enclosed in a capillary. The device is easy to use and delivers gas volume data at a rate of more than 15 measurements/s and a resolution better than 0.06 {mu}l. At the onset of a gas quantity change the sensor shows a small pressure artifact of less than 15 Pa, and at constant change rates the pressure artifact is smaller than 10 Pa or 0.01% of ambient pressure.« less
Laser heating and detection of bilayer microcantilevers for non-contact thermodynamic measurements
NASA Astrophysics Data System (ADS)
Burke, Brian G.; LaVan, David A.
2013-01-01
We describe a method for optical detection (frequency and position) and heating of bilayer microcantilevers (BMCs) to high temperatures at fast heating rates (106°C/s to 109°C/s) for non-contact thermodynamic measurements of small quantities of materials in the femtogram range. The current experimental apparatus with a 2 μm × 10 μm BMC achieves a deflection sensitivity of 0.1 Å, heating rate of 3.0 × 106°C/s, and heat sensitivity of 18 pJ in a 3 kHz bandwidth in air. By measuring the resonant frequency shift after sample loading, we achieve a mass resolution of 2.67 fg.
ARPA surveillance technology for detection of targets hidden in foliage
NASA Astrophysics Data System (ADS)
Hoff, Lawrence E.; Stotts, Larry B.
1994-02-01
The processing of large quantities of synthetic aperture radar data in real time is a complex problem. Even the image formation process taxes today's most advanced computers. The use of complex algorithms with multiple channels adds another dimension to the computational problem. Advanced Research Projects Agency (ARPA) is currently planning on using the Paragon parallel processor for this task. The Paragon is small enough to allow its use in a sensor aircraft. Candidate algorithms will be implemented on the Paragon for evaluation for real time processing. In this paper ARPA technology developments for detecting targets hidden in foliage are reviewed and examples of signal processing techniques on field collected data are presented.
Vortex flows in the solar chromosphere. I. Automatic detection method
NASA Astrophysics Data System (ADS)
Kato, Y.; Wedemeyer, S.
2017-05-01
Solar "magnetic tornadoes" are produced by rotating magnetic field structures that extend from the upper convection zone and the photosphere to the corona of the Sun. Recent studies show that these kinds of rotating features are an integral part of atmospheric dynamics and occur on a large range of spatial scales. A systematic statistical study of magnetic tornadoes is a necessary next step towards understanding their formation and their role in mass and energy transport in the solar atmosphere. For this purpose, we develop a new automatic detection method for chromospheric swirls, meaning the observable signature of solar tornadoes or, more generally, chromospheric vortex flows and rotating motions. Unlike existing studies that rely on visual inspections, our new method combines a line integral convolution (LIC) imaging technique and a scalar quantity that represents a vortex flow on a two-dimensional plane. We have tested two detection algorithms, based on the enhanced vorticity and vorticity strength quantities, by applying them to three-dimensional numerical simulations of the solar atmosphere with CO5BOLD. We conclude that the vorticity strength method is superior compared to the enhanced vorticity method in all aspects. Applying the method to a numerical simulation of the solar atmosphere reveals very abundant small-scale, short-lived chromospheric vortex flows that have not been found previously by visual inspection.
Tunable Impedance Spectroscopy Sensors via Selective Nanoporous Materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nenoff, Tina M.; Small, Leo J
Impedance spectroscopy was leveraged to directly detect the sorption of I 2 by selective adsorption into nanoporous metal organic frameworks (MOF). Films of three different types of MOF frameworks, respectively, were drop cast onto platinum interdigitated electrodes, dried, and exposed to gaseous I 2 at 25, 40, or 70 C. The MOF frameworks varied in topology from small pores (equivalent to I 2 diameter) to large pore frameworks. The combination of the chemistry of the framework and pore size dictated quantity and kinetics of I 2 adsorption. Air, argon, methanol, and water were found to produce minimal changes in ZIF-8more » impedance. Independent of MOF framework characteristics, all resultant sensors showed high response to I 2 in air. As an example of sensor output, I 2 was readily detected at 25 C in air within 720 s of exposure, using an un-optimized sensor geometry with a small pored MOF. Further optimization of sensor geometry, decreasing MOF film thicknesses and maximizing sensor capacitance, will enable faster detection of trace I 2 .« less
40 CFR 747.195 - Triethanolamine salt of a substituted organic acid.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., commerce, importer, impurity, Inventory, manufacturer, person, process, processor, and small quantities... control of the processor. (ii) Distribution in commerce is limited to purposes of export. (iii) The processor or distributor may not use the substance except in small quantities solely for research and...
40 CFR 273.13 - Waste management.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Waste management. 273.13 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste § 273.13 Waste management. (a) Universal waste batteries. A small quantity handler of universal waste must manage...
40 CFR 273.19 - Tracking universal waste shipments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Tracking universal waste shipments... WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste § 273.19 Tracking universal waste shipments. A small quantity handler of universal waste is...
Innovations in biomedical nanoengineering: nanowell array biosensor.
Seo, YoungTae; Jeong, Sunil; Lee, JuKyung; Choi, Hak Soo; Kim, Jonghan; Lee, HeaYeon
2018-01-01
Nanostructured biosensors have pioneered biomedical engineering by providing highly sensitive analyses of biomolecules. The nanowell array (NWA)-based biosensing platform is particularly innovative, where the small size of NWs within the array permits extremely profound sensing of a small quantity of biomolecules. Undoubtedly, the NWA geometry of a gently-sloped vertical wall is critical for selective docking of specific proteins without capillary resistances, and nanoprocessing has contributed to the fabrication of NWA electrodes on gold substrate such as molding process, e-beam lithography, and krypton-fluoride (KrF) stepper semiconductor method. The Lee group at the Mara Nanotech has established this NW-based biosensing technology during the past two decades by engineering highly sensitive electrochemical sensors and providing a broad range of detection methods from large molecules (e.g., cells or proteins) to small molecules (e.g., DNA and RNA). Nanosized gold dots in the NWA enhance the detection of electrochemical biosensing to the range of zeptomoles in precision against the complementary target DNA molecules. In this review, we discuss recent innovations in biomedical nanoengineering with a specific focus on novel NWA-based biosensors. We also describe our continuous efforts in achieving a label-free detection without non-specific binding while maintaining the activity and stability of immobilized biomolecules. This research can lay the foundation of a new platform for biomedical nanoengineering systems.
Innovations in biomedical nanoengineering: nanowell array biosensor
NASA Astrophysics Data System (ADS)
Seo, YoungTae; Jeong, Sunil; Lee, JuKyung; Choi, Hak Soo; Kim, Jonghan; Lee, HeaYeon
2018-04-01
Nanostructured biosensors have pioneered biomedical engineering by providing highly sensitive analyses of biomolecules. The nanowell array (NWA)-based biosensing platform is particularly innovative, where the small size of NWs within the array permits extremely profound sensing of a small quantity of biomolecules. Undoubtedly, the NWA geometry of a gently-sloped vertical wall is critical for selective docking of specific proteins without capillary resistances, and nanoprocessing has contributed to the fabrication of NWA electrodes on gold substrate such as molding process, e-beam lithography, and krypton-fluoride (KrF) stepper semiconductor method. The Lee group at the Mara Nanotech has established this NW-based biosensing technology during the past two decades by engineering highly sensitive electrochemical sensors and providing a broad range of detection methods from large molecules (e.g., cells or proteins) to small molecules (e.g., DNA and RNA). Nanosized gold dots in the NWA enhance the detection of electrochemical biosensing to the range of zeptomoles in precision against the complementary target DNA molecules. In this review, we discuss recent innovations in biomedical nanoengineering with a specific focus on novel NWA-based biosensors. We also describe our continuous efforts in achieving a label-free detection without non-specific binding while maintaining the activity and stability of immobilized biomolecules. This research can lay the foundation of a new platform for biomedical nanoengineering systems.
Active detection of shielded SNM with 60-keV neutrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagmann, C; Dietrich, D; Hall, J
2008-07-08
Fissile materials, e.g. {sup 235}U and {sup 239}Pu, can be detected non-invasively by active neutron interrogation. A unique characteristic of fissile material exposed to neutrons is the prompt emission of high-energy (fast) fission neutrons. One promising mode of operation subjects the object to a beam of medium-energy (epithermal) neutrons, generated by a proton beam impinging on a Li target. The emergence of fast secondary neutrons then clearly indicates the presence of fissile material. Our interrogation system comprises a low-dose 60-keV neutron generator (5 x 10{sup 6}/s), and a 1 m{sup 2} array of scintillators for fast neutron detection. Preliminary experimentalmore » results demonstrate the detectability of small quantities (370 g) of HEU shielded by steel (200 g/cm{sup 2}) or plywood (30 g/cm{sup 2}), with a typical measurement time of 1 min.« less
Hazardous Waste Management for the Small Quantity Generator. Teacher Edition.
ERIC Educational Resources Information Center
Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.
This instructional package for teaching about the regulations imposed on small quantity generators by the Environmental Protection Agency (EPA) under the Resource Conservation Recovery Act is organized around ll program objectives: students will be able to (l) determine a hazardous waste from lists or by identifying characteristics; (2) identify…
Calès, P; Zarski, J P; Chapplain, J Marc; Bertrais, S; Sturm, N; Michelet, C; Babany, G; Chaigneau, J; Eddine Charaf, M
2012-02-01
We evaluated whether quantitative measurements of liver fibrosis with recently developed diagnostics outperform histological staging in detecting natural or interferon-induced changes. We compared Metavir staging, morphometry (area and fractal dimension) and six blood tests in 157 patients with chronic hepatitis C from two trials testing maintenance interferon for 96 weeks. Paired liver biopsies and blood tests were available for 101 patients, and there was a significant improvement in Metavir activity and a significant increase in blood tests reflecting fibrosis quantity in patients treated with interferon when compared with controls - all per cent changes in histological fibrosis measures were significantly increased in F1 vs F2-4 stages only in the interferon group. For the whole population studied between weeks 0 and 96, there was significant progression only in the area of fibrosis (AOF) (P = 0.026), FibroMeter (P = 0.020) and CirrhoMeter (P = 0.003). With regards to dynamic reproducibility, agreement was good (r(ic) ≥ 0.72) only for Metavir fibrosis score, FibroMeter and CirrhoMeter. The per cent change in AOF was significantly higher than that of fractal dimension (P = 0.003) or Metavir fibrosis score (P = 0.015). CirrhoMeter was the only blood test with a change significantly higher than that of AOF (P = 0.039). AOF and two blood tests, reflecting fibrosis quantity, have high sensitivity and/or reproducibility permitting the detection of a small progression in liver fibrosis over two years. A blood test reflecting fibrosis quantity is more sensitive and reproducible than morphometry. The study also shows that maintenance interferon does not improve fibrosis, whatever its stage. © 2011 Blackwell Publishing Ltd.
Testing of concrete by laser ablation
Flesher, Dann J.; Becker, David L.; Beem, William L.; Berry, Tommy C.; Cannon, N. Scott
1997-01-01
A method of testing concrete in a structure in situ, by: directing a succession of pulses of laser radiation at a point on the structure so that each pulse effects removal of a quantity of concrete and transfers energy to the concrete; detecting a characteristic of energy which has been transferred to the concrete; determining, separately from the detecting step, the total quantity of concrete removed by the succession of pulses; and calculating a property of the concrete on the basis of the detected energy characteristic and the determined total quantity of concrete removed.
2012-01-10
flow cytometry, locked nucleic acid, sRNA, Vibrio , Date Published: 1/10/2012 This is an open-access article distributed under the terms of the Creative...solubilization process to maintain a 10 mL volume. Aliquot the 60% dextran sulfate solution and store at -20 °C until use. 1. Harvest 1x108 cells of...bioluminescent Vibrio campbellii or your bacteria of interest and transfer them into a 1.5 mL microcentrifuge tube. This quantity of cells provides
Dispersion of gravitational waves in cold spherical interstellar medium
NASA Astrophysics Data System (ADS)
Barta, Dániel; Vasúth, Mátyás
We investigate the propagation of locally plane, small-amplitude, monochromatic gravitational waves (GWs) through cold compressible interstellar gas in order to provide a more accurate picture of expected waveforms for direct detection. The quasi-isothermal gas is concentrated in a spherical symmetric cloud held together by self-gravitation. Gravitational waves can be treated as linearized perturbations on the background inner Schwarzschild spacetime. The perturbed quantities lead to the field equations governing the gas dynamics and describe the interaction of gravitational waves with matter. We have shown that the transport equation of these amplitudes provides numerical solutions for the frequency-alteration. The decrease in frequency is driven by the energy dissipating process of GW-matter interactions. The decrease is significantly smaller than the magnitude of the original frequency and too small to be detectable by present second-generation and planned third-generation detectors. It exhibits a power-law relationship between original and decreased frequencies. The frequency deviation was examined particularly for the transient signal GW150914.
NASA Technical Reports Server (NTRS)
Duhon, D. D.
1975-01-01
The shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module computes the quantity of usable OMS propellant remaining based on the real gas P-V-T relationship for the propellant tank pressurant, helium. The OMS P-V-T propellant quantity gaging error was determined for four sets of instrumentation configurations and accuracies with the propellant tank operating in the normal constant pressure mode and in the blowdown mode. The instrumentation inaccuracy allowance for propellant leak detection was also computed for these same four sets of instrumentation. These gaging errors and leak detection allowances are presented in tables designed to permit a direct comparison of the effectiveness of the four instrumentation sets. The results show the magnitudes of the improvements in propellant quantity gaging accuracies and propellant leak detection allowances which can be achieved by employing more accurate pressure and temperature instrumentation.
Chemical Waste Management for the Conditionally Exempt Small Quantity Generator
NASA Astrophysics Data System (ADS)
Zimmer, Steven W.
1999-06-01
Management of hazardous chemical wastes generated as a part of the curriculum poses a significant task for the individual responsible for maintaining compliance with all rules and regulations from the Environmental Protection Agency and the Department of Transportation while maintaining the principles of OSHA's Lab Standard and the Hazard Communication Standard. For schools that generate relatively small quantities of waste, an individual can effectively manage the waste program without becoming overly burdened by the EPA regulations required for those generating large quantities of waste, if given the necessary support from the institution.
Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens.
Tang, Yi-Wei; Sefers, Susan E; Li, Haijing; Kohn, Debra J; Procop, Gary W
2005-09-01
A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.
NASA Technical Reports Server (NTRS)
1994-01-01
The ChemScan UV-6100 is a spectrometry system originally developed by Biotronics Technologies, Inc. under a Small Business Innovation Research (SBIR) contract. It is marketed to the water and wastewater treatment industries, replacing "grab sampling" with on-line data collection. It analyzes the light absorbance characteristics of a water sample, simultaneously detects hundreds of individual wavelengths absorbed by chemical substances in a process solution, and quantifies the information. Spectral data is then processed by ChemScan analyzer and compared with calibration files in the system's memory in order to calculate concentrations of chemical substances that cause UV light absorbance in specific patterns. Monitored substances can be analyzed for quality and quantity. Applications include detection of a variety of substances, and the information provided enables an operator to control a process more efficiently.
Fleming, Damarius S; Miller, Laura C
2018-04-01
It has been established that reduced susceptibility to porcine reproductive and respiratory syndrome virus (PRRSV) has a genetic component. This genetic component may take the form of small non-coding RNAs (sncRNA), which are molecules that function as regulators of gene expression. Various sncRNAs have emerged as having an important role in the immune system in humans. The study uses transcriptomic read counts to profile the type and quantity of both well and lesser characterized sncRNAs, such as microRNAs and small nucleolar RNAs to identify and quantify the classes of sncRNA expressed in whole blood between healthy and highly pathogenic PRRSV-infected pigs. Our results returned evidence on nine classes of sncRNA, four of which were consistently statistically significantly different based on Fisher's Exact Test, that can be detected and possibly interrogated for their effect on host dysregulation during PRRSV infections. Published by Elsevier Inc.
Testing of concrete by laser ablation
Flesher, D.J.; Becker, D.L.; Beem, W.L.; Berry, T.C.; Cannon, N.S.
1997-01-07
A method is disclosed for testing concrete in a structure in situ, by: directing a succession of pulses of laser radiation at a point on the structure so that each pulse effects removal of a quantity of concrete and transfers energy to the concrete; detecting a characteristic of energy which has been transferred to the concrete; determining, separately from the detecting step, the total quantity of concrete removed by the succession of pulses; and calculating a property of the concrete on the basis of the detected energy characteristic and the determined total quantity of concrete removed. 1 fig.
Methods to maximise recovery of environmental DNA from water samples.
Hinlo, Rheyda; Gleeson, Dianne; Lintermans, Mark; Furlan, Elise
2017-01-01
The environmental DNA (eDNA) method is a detection technique that is rapidly gaining credibility as a sensitive tool useful in the surveillance and monitoring of invasive and threatened species. Because eDNA analysis often deals with small quantities of short and degraded DNA fragments, methods that maximize eDNA recovery are required to increase detectability. In this study, we performed experiments at different stages of the eDNA analysis to show which combinations of methods give the best recovery rate for eDNA. Using Oriental weatherloach (Misgurnus anguillicaudatus) as a study species, we show that various combinations of DNA capture, preservation and extraction methods can significantly affect DNA yield. Filtration using cellulose nitrate filter paper preserved in ethanol or stored in a -20°C freezer and extracted with the Qiagen DNeasy kit outperformed other combinations in terms of cost and efficiency of DNA recovery. Our results support the recommendation to filter water samples within 24hours but if this is not possible, our results suggest that refrigeration may be a better option than freezing for short-term storage (i.e., 3-5 days). This information is useful in designing eDNA detection of low-density invasive or threatened species, where small variations in DNA recovery can signify the difference between detection success or failure.
Seasoning small quantities of lumber
E.F. Rasmussen
1965-01-01
The owner of a small quantity of green lumber or logs is often confronted with seasoning it to a state of dryness suitable for use in furniture, wood carving, or other handiwork. He cannot follow the practice of commercial mills, which employ dry kilns for the purpose. because kilns are too costly. On the other hand, air seasoning outdoors usually does not dry lumber...
A novel device for quantitative measurement of chloride concentration by fluorescence indicator
NASA Astrophysics Data System (ADS)
Wang, Junsheng; Wu, Xudong; Chon, Chanhee; Gonska, Tanja; Li, Dongqing
2012-02-01
Cystic fibrosis (CF) is a life-threatening genetic disease. At present, the common method for diagnosis of CF is to detect the chloride concentration in sweat using ion-selective electrodes. However, the current sweat testing methods require a relatively large quantity of sweat sample, at least 25 µL, which is very difficult to obtain, especially for newborns. This paper presents a new method and a new device for rapid detection of the chloride concentration from a small volume of solution. In this method, the chloride concentration is determined quantitatively by the fluorescence intensity of MQAE, a chloride ion fluorescent indicator. In this device, the sample is carried by a small piece of filter paper on a cover glass exposed to an UV LED light source. The resulting fluorescent signals are detected by a Si photodiode. Data acquisition and processing are accomplished by LabVIEW software in a PDA. Based on the Stern-Volmer relationship, the effects of different parameters on the fluorescence intensity were analyzed. The observed significant difference between 40 and 60 mM (the borderline of chloride concentration for CF) is discussed in this paper. The results show that detection can be completed within 10 s. The minimum detectable volume of the chloride solution is 1 μL. The novel method and the device are of great potential for CF diagnosis.
Chirality detection of enantiomers using twisted optical metamaterials
NASA Astrophysics Data System (ADS)
Zhao, Yang; Askarpour, Amir N.; Sun, Liuyang; Shi, Jinwei; Li, Xiaoqin; Alù, Andrea
2017-01-01
Many naturally occurring biomolecules, such as amino acids, sugars and nucleotides, are inherently chiral. Enantiomers, a pair of chiral isomers with opposite handedness, often exhibit similar physical and chemical properties due to their identical functional groups and composition, yet show different toxicity to cells. Detecting enantiomers in small quantities has an essential role in drug development to eliminate their unwanted side effects. Here we exploit strong chiral interactions with plasmonic metamaterials with specifically designed optical response to sense chiral molecules down to zeptomole levels, several orders of magnitude smaller than what is typically detectable with conventional circular dichroism spectroscopy. In particular, the measured spectra reveal opposite signs in the spectral regime directly associated with different chiral responses, providing a way to univocally assess molecular chirality. Our work introduces an ultrathin, planarized nanophotonic interface to sense chiral molecules with inherently weak circular dichroism at visible and near-infrared frequencies.
NASA Technical Reports Server (NTRS)
Steele, A.; Whitby, C.; Griffin, C.; Toporski, J. K. W.; Westall, F.; Saunders, J. R.; McKay, D. S.
2001-01-01
The arguments used to refute the McKay et al., (1996) hypothesis of possible Martian life in ALH84001 failed to use contamination of the meteorite as a source. This has worrying implications for our ability to detect terrestrial microbiota in meteorites and therefore any potential extraterrestrial biosignatures in both meteorites and possible returned samples. We report on imaging and microbial culturing of both Allende and Murchison carbonaceous chondrites and on the use of molecular biology techniques on a sample of Allende. Contaminating fungi and bacteria were observed (in the case of Murchison) and cultured from both meteorites. DNA was successfully extracted and subsequent PCR showed the presence of both bacterial and fungal DNA although no Archaea were detected. These results show that it is possible to use molecular biological techniques on very small quantities (300 mg) of extraterrestrial material.
Chirality detection of enantiomers using twisted optical metamaterials
Zhao, Yang; Askarpour, Amir N.; Sun, Liuyang; Shi, Jinwei; Li, Xiaoqin; Alù, Andrea
2017-01-01
Many naturally occurring biomolecules, such as amino acids, sugars and nucleotides, are inherently chiral. Enantiomers, a pair of chiral isomers with opposite handedness, often exhibit similar physical and chemical properties due to their identical functional groups and composition, yet show different toxicity to cells. Detecting enantiomers in small quantities has an essential role in drug development to eliminate their unwanted side effects. Here we exploit strong chiral interactions with plasmonic metamaterials with specifically designed optical response to sense chiral molecules down to zeptomole levels, several orders of magnitude smaller than what is typically detectable with conventional circular dichroism spectroscopy. In particular, the measured spectra reveal opposite signs in the spectral regime directly associated with different chiral responses, providing a way to univocally assess molecular chirality. Our work introduces an ultrathin, planarized nanophotonic interface to sense chiral molecules with inherently weak circular dichroism at visible and near-infrared frequencies. PMID:28120825
Microfluidic devices, systems, and methods for quantifying particles using centrifugal force
Schaff, Ulrich Y.; Sommer, Gregory J.; Singh, Anup K.
2015-11-17
Embodiments of the present invention are directed toward microfluidic systems, apparatus, and methods for measuring a quantity of cells in a fluid. Examples include a differential white blood cell measurement using a centrifugal microfluidic system. A method may include introducing a fluid sample containing a quantity of cells into a microfluidic channel defined in part by a substrate. The quantity of cells may be transported toward a detection region defined in part by the substrate, wherein the detection region contains a density media, and wherein the density media has a density lower than a density of the cells and higher than a density of the fluid sample. The substrate may be spun such that at least a portion of the quantity of cells are transported through the density media. Signals may be detected from label moieties affixed to the cells.
Parrish, Audrey E.; Beran, Michael J.
2014-01-01
The context in which food is presented can alter quantity judgments leading to sub-optimal choice behavior. Humans often over-estimate food quantity on the basis of how food is presented. Food appears larger if plated on smaller dishes than larger dishes and liquid volumes appear larger in taller cups than shorter cups. Moreover, smaller but fuller containers are preferred in comparison to larger, but less full containers with a truly larger quantity. Here, we assessed whether similar phenomena occur in chimpanzees. Four chimpanzees chose between two amounts of food presented in different sized containers, a large (2 oz.) and small (1 oz.) cup. When different quantities were presented in the same-sized cups or when the small cup contained the larger quantity, chimpanzees were highly accurate in choosing the larger food amount. However, when different-sized cups contained the same amount of food or the smaller cup contained the smaller amount of food (but looked relatively fuller), the chimpanzees often showed a bias to select the smaller but fuller cup. These findings contribute to our understanding of how quantity estimation and portion judgment is impacted by the surrounding context in which it is presented. PMID:24374384
Modern Directions for Potentiometric Sensors
Bakker, Eric; Chumbimuni-Torres, Karin
2009-01-01
This paper gives an overview of the newest developments of polymeric membrane ion-selective electrodes. A short essence of the underlying theory is given, emphasizing how the electromotive force may be used to assess binding constants of the ionophore, and how the selectivity and detection limit are related to the underlying membrane processes. The recent developments in lowering the detection limits of ISEs are described, including recent approaches of developing all solid state ISEs, and breakthroughs in detecting ultra-small quantities of ions at low concentrations. These developments have paved the way to use potentiometric sensors as in ultra-sensitive affinity bioanalysis in conjunction with nanoparticle labels. Recent results establish that potentiometry compares favorably to electrochemical stripping analysis. Other new developments with ion-selective electrodes are also described, including the concept of backside calibration potentiometry, controlled current coulometry, pulsed chronopotentiometry, and localized flash titration with ion-selective membranes to design sensors for the direct detection of total acidity without net sample perturbation. These developments have further opened the field for exciting new possibilities and applications. PMID:19890473
Technical approaches to reducing the threat of nuclear terrorism
NASA Astrophysics Data System (ADS)
Priedhorsky, William C.
2005-04-01
The threat of a nuclear attack on the United States by terrorists using a smuggled weapon is now considered more likely than an attack by a nuclear-armed ballistic missle. Consequently it is important to understand what can be done to detect and intercept a nuclear weapon being smuggled into the United States. A significant quantity of smuggled nuclear material has been intercepted already, but science and technology have so far contributed little to its interception. The critical special nuclear materials, plutonium and highly enriched uranium, are only weakly radioactive and detection of their radioactivity is limited both by atmospheric attenuation and by competition with natural backgrounds. Although many schemes for long-range detection of radioactivity have been proposed, none so far appears feasible. Detection of nuclear radiation can be improved using new technologies and sensing systems, but it will still be possible only at relatively small distances. Consequently the best approach to containing dangerous nuclear materials is at their sources; containment within lengthy borders and large areas is extremely difficult.
High-resolution streaming video integrated with UGS systems
NASA Astrophysics Data System (ADS)
Rohrer, Matthew
2010-04-01
Imagery has proven to be a valuable complement to Unattended Ground Sensor (UGS) systems. It provides ultimate verification of the nature of detected targets. However, due to the power, bandwidth, and technological limitations inherent to UGS, sacrifices have been made to the imagery portion of such systems. The result is that these systems produce lower resolution images in small quantities. Currently, a high resolution, wireless imaging system is being developed to bring megapixel, streaming video to remote locations to operate in concert with UGS. This paper will provide an overview of how using Wifi radios, new image based Digital Signal Processors (DSP) running advanced target detection algorithms, and high resolution cameras gives the user an opportunity to take high-powered video imagers to areas where power conservation is a necessity.
Free-ranging dogs assess the quantity of opponents in intergroup conflicts.
Bonanni, Roberto; Natoli, Eugenia; Cafazzo, Simona; Valsecchi, Paola
2011-01-01
In conflicts between social groups, the decision of competitors whether to attack/retreat should be based on the assessment of the quantity of individuals in their own and the opposing group. Experimental studies on numerical cognition in animals suggest that they may represent both large and small numbers as noisy mental magnitudes subject to scalar variability, and small numbers (≤4) also as discrete object-files. Consequently, discriminating between large quantities, but not between smaller ones, should become easier as the asymmetry between quantities increases. Here, we tested these hypotheses by recording naturally occurring conflicts in a population of free-ranging dogs, Canis lupus familiaris, living in a suburban environment. The overall probability of at least one pack member approaching opponents aggressively increased with a decreasing ratio of the number of rivals to that of companions. Moreover, the probability that more than half of the pack members withdrew from a conflict increased when this ratio increased. The skill of dogs in correctly assessing relative group size appeared to improve with increasing the asymmetry in size when at least one pack comprised more than four individuals, and appeared affected to a lesser extent by group size asymmetries when dogs had to compare only small numbers. These results provide the first indications that a representation of quantity based on noisy mental magnitudes may be involved in the assessment of opponents in intergroup conflicts and leave open the possibility that an additional, more precise mechanism may operate with small numbers.
Tang, Te; Weiss, Michael D; Borum, Peggy; Turovets, Sergei; Tucker, Don; Sadleir, Rosalind
2016-06-01
Intraventricular hemorrhage (IVH) is a common occurrence in the days immediately after premature birth. It has been correlated with outcomes such as periventricular leukomalacia (PVL), cerebral palsy and developmental delay. The causes and evolution of IVH are unclear; it has been associated with fluctuations in blood pressure, damage to the subventricular zone and seizures. At present, ultrasound is the most commonly used method for detection of IVH, but is used retrospectively. Without the presence of adequate therapies to avert IVH, the use of a continuous monitoring technique may be somewhat moot. While treatments to mitigate the damage caused by IVH are still under development, the principal benefit of a continuous monitoring technique will be in investigations into the etiology of IVH, and its associations with periventricular injury and blood pressure fluctuations. Electrical impedance tomography (EIT) is potentially of use in this context as accumulating blood displaces higher conductivity cerebrospinal fluid (CSF) in the ventricles. We devised an electrode array and EIT measurement strategy that performed well in detection of simulated ventricular blood in computer models and phantom studies. In this study we describe results of pilot in vivo experiments on neonatal piglets, and show that EIT has high sensitivity and specificity to small quantities of blood (<1 ml) introduced into the ventricle. EIT images were processed to an index representing the quantity of accumulated blood (the 'quantity index', QI). We found that QI values were linearly related to fluid quantity, and that the slope of the curve was consistent between measurements on different subjects. Linear discriminant analysis showed a false positive rate of 0%, and receiver operator characteristic analysis found area under curve values greater than 0.98 to administered volumes between 0.5, and 2.0 ml. We believe our study indicates that this method may be well suited to quantitative monitoring of IVH in newborns, simultaneously or interleaved with electroencephalograph assessments.
Wijesinghe, Priyanga; Bepler, Gerold
2014-01-01
Introduction ROS1 and RET gene fusions were recently discovered in non-small cell lung cancer (NSCLC) as potential therapeutic targets with small molecule kinase inhibitors. The conventional screening methods of these fusions are time consuming and require samples of high quality and quantity. Here, we describe a novel and efficient method by coupling the power of multiplexing PCR and the sensitivity of mass spectrometry. Methods The multiplex mass spectrometry platform simultaneously tests samples for the expression of nine ROS1 and six RET fusion genes. The assay incorporates detection of wild-type exon junctions immediately upstream and downstream of the fusion junction to exclude false negative results. To flag false positives, the system also comprises two independent assays for each fusion gene junction. Results The characteristic mass spectrometric peaks of the gene fusions were obtained using engineered plasmid constructs. Specific assays targeting the wild-type gene exon junctions were validated using cDNA from lung tissue of healthy individuals. The system was further validated using cDNA derived from NSCLC cell lines that express endogenous fusion genes. The expressed ROS1-SLC34A2 and CCDC6-RET gene fusions from the NSCLC cell lines HCC78 and LC-2/ad, respectively, were accurately detected by the novel assay. The assay is extremely sensitive, capable of detecting an event in test specimens containing 0.5% positive tumors. Conclusion The novel multiplexed assay is robustly capable of detecting 15 different clinically relevant RET and ROS1 fusion variants. The benefits of this detection method include exceptionally low sample input, high cost efficiency, flexibility, and rapid turnover. PMID:25384172
Linear actuation using milligram quantities of CL-20 and TAGDNAT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snedigar, Shane; Salton, Jonathan Robert; Tappan, Alexander Smith
2009-07-01
There are numerous applications for small-scale actuation utilizing pyrotechnics and explosives. In certain applications, especially when multiple actuation strokes are needed, or actuator reuse is required, it is desirable to have all gaseous combustion products with no condensed residue in the actuator cylinder. Toward this goal, we have performed experiments on utilizing milligram quantities of high explosives to drive a millimeter-diameter actuator with a stroke of 30 mm. Calculations were performed to select proper material quantities to provide 0.5 J of actuation energy. This was performed utilizing the thermochemical code Cheetah to calculate the impetus for numerous propellants and tomore » select quantities based on estimated efficiencies of these propellants at small scales. Milligram quantities of propellants were loaded into a small-scale actuator and ignited with an ignition increment and hot wire ignition. Actuator combustion chamber pressure was monitored with a pressure transducer and actuator stroke was monitored using a laser displacement meter. Total actuation energy was determined by calculating the kinetic energy of reaction mass motion against gravity. Of the materials utilized, the best performance was obtained with a mixture of 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (CL-20) and bis-triaminoguanidinium(3,3{prime}dinitroazotriazolate) (TAGDNAT).« less
Santman-Berends, Inge; Luttikholt, Saskia; den Brom, René Van; Schaik, Gerdien Van; Gonggrijp, Maaike; Hage, Han; Vellema, Piet
2014-01-01
The aim of this study was to estimate the quantity of antibiotics and classes of antibiotics used in the small ruminant industry in the Netherlands in 2011 and 2012. Twelve large veterinary practices, located throughout the Netherlands were selected for this study. All small ruminant farms associated with these practices that had complete records on the quantity of antibiotics prescribed were included. The veterinary practices provided data on all antibiotics prescribed, and the estimated animal used daily dose of antibiotics per year (AUDD/Y) was calculated for each farm. The median AUDD/Y in small ruminant farms was zero in both years (mean 0.60 in 2011, and 0.62 in 2012). The largest quantity of antibiotic use was observed in the professional goat industry (herds of ≥32 goats) with a median AUDD/Y of 1.22 in 2011 and 0.73 in 2012. In the professional sheep industry (flocks of ≥32 sheep), the median AUDD/Y was 0 in 2011 and 0.10 in 2012. In the small scale industry (flocks or herds of <32 sheep or goats), the median AUDD/Y never exceeded 0. The most frequently prescribed antibiotics in the small scale industry and professional sheep farms belonged to the penicillin class. In professional goat farms, antibiotics of the aminoglycoside class were most frequently prescribed. This study provides the first assessment on the quantity of antibiotic use in the small ruminant industry. Given a comparable attitude towards antibiotic use, these results might be valid for small ruminant populations in other north-western European countries as well. The antibiotic use in the small ruminant industry appeared to be low, and is expected to play a minor role in the development of antibiotic resistance. Nevertheless, several major zoonotic bacterial pathogens are associated with the small ruminant industry, and it remains important that antibiotics are used in a prudent way. PMID:25115998
Quantity Representation in Children and Rhesus Monkeys: Linear Versus Logarithmic Scales
ERIC Educational Resources Information Center
Beran, Michael J.; Johnson-Pynn, Julie S.; Ready, Christopher
2008-01-01
The performances of 4- and 5-year-olds and rhesus monkeys were compared using a computerized task for quantity assessment. Participants first learned two quantity anchor values and then responded to intermediate values by classifying them as similar to either the large anchor or the small anchor. Of primary interest was an assessment of where the…
Barcode DNA length polymorphisms vs fatty acid profiling for adulteration detection in olive oil.
Uncu, Ali Tevfik; Uncu, Ayse Ozgur; Frary, Anne; Doganlar, Sami
2017-04-15
The aim of this study was to compare the performance of a DNA-barcode assay with fatty acid profile analysis to authenticate the botanical origin of olive oil. To achieve this aim, we performed a PCR-capillary electrophoresis (PCR-CE) approach on olive oil: seed oil blends using the plastid trnL (UAA) intron barcode. In parallel to genomic analysis, we subjected the samples to gas chromatography analysis of fatty acid composition. While the PCR-CE assay proved equally efficient as gas chromatography analysis in detecting adulteration with soybean, palm, rapeseed, sunflower, sesame, cottonseed and peanut oils, it was superior to the widely utilized analytical chemistry approach in revealing the adulterant species and detecting small quantities of corn and safflower oils in olive oil. Moreover, the DNA-based test correctly identified all tested olive oil: hazelnut oil blends whereas it was not feasible to detect hazelnut oil adulteration through fatty acid profile analysis. Thus, the present research has shown the feasibility of a PCR-CE barcode assay to detect adulteration in olive oil. Copyright © 2016 Elsevier Ltd. All rights reserved.
Barret, Laurie-Anne; Polidori, Ange; Bonneté, Françoise; Bernard-Savary, Pierre; Jungas, Colette
2013-03-15
The hydrophobic nature of membrane proteins (MPs) necessitates the use of detergents for their extraction, solubilization and purification. Because the concentration of amphiphiles is crucial in the crystallization process, detergent quantification is essential to routine analysis. Here we describe a quantitative high-performance thin-layer chromatography (HPTLC) method we developed for the detection of small quantities of detergent bound to solubilized MPs. After optimization of aqueous deposit conditions, we show that most detergents widely used in membrane protein crystallography display distinctive mobilities in a mixture of dichloromethane, methanol and acetic acid 32:7.6:0.4 (v/v/v). Migration and derivatization conditions were optimized with n-dodecyl-β-D-maltoside (DDM), the most popular detergent for membrane protein crystallization. A linear calibration curve very well fits our data from 0.1 to 1.6 μg of DDM in water with a limit of detection of 0.05 μg. This limit of detection is the best achieved to date for a routine detergent assay, being not modified by the addition of NaCl, commonly used in protein buffers. With these chromatographic conditions, no prior treatment is required to assess the quantities of detergent bound to purified MPs, thus enabling the quantification of close structure detergents via a single procedure. This HPTLC method, which is fast and requires low sample volume, is fully suitable for routine measurements. Copyright © 2013 Elsevier B.V. All rights reserved.
How tobacco companies have used package quantity for consumer targeting.
Persoskie, Alexander; Donaldson, Elisabeth A; Ryant, Chase
2018-05-31
Package quantity refers to the number of cigarettes or amount of other tobacco product in a package. Many countries restrict minimum cigarette package quantities to avoid low-cost packs that may lower barriers to youth smoking. We reviewed Truth Tobacco Industry Documents to understand tobacco companies' rationales for introducing new package quantities, including companies' expectations and research regarding how package quantity may influence consumer behaviour. A snowball sampling method (phase 1), a static search string (phase 2) and a follow-up snowball search (phase 3) identified 216 documents, mostly from the 1980s and 1990s, concerning cigarettes (200), roll-your-own tobacco (9), smokeless tobacco (6) and 'smokeless cigarettes' (1). Companies introduced small and large packages to motivate brand-switching and continued use among current users when faced with low market share or threats such as tax-induced price increases or competitors' use of price promotions. Companies developed and evaluated package quantities for specific brands and consumer segments. Large packages offered value-for-money and matched long-term, heavy users' consumption rates. Small packages were cheaper, matched consumption rates of newer and lighter users, and increased products' novelty, ease of carrying and perceived freshness. Some users also preferred small packages as a way to try to limit consumption or quit. Industry documents speculated about many potential effects of package quantity on appeal and use, depending on brand and consumer segment. The search was non-exhaustive, and we could not assess the quality of much of the research or other information on which the documents relied. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Gravitational waves with dark matter minispikes: The combined effect
NASA Astrophysics Data System (ADS)
Yue, Xiao-Jun; Han, Wen-Biao
2018-03-01
It was shown that the dark matter (DM) minihalo around an intermediate mass black hole (IMBH) can be redistributed into a cusp, called the DM minispike. We consider an intermediate-mass-ratio inspiral consisting of an IMBH harbored in a DM minispike with nonannihilating DM particles and a small black hole (BH) orbiting around it. We investigate gravitational waves (GWs) produced by this system and analyze the waveforms with the comprehensive consideration of gravitational pull, dynamical friction and accretion of the minispike and calculate the time difference and phase difference caused by it. We find that for a certain range of frequency, the inspiralling time of the system is dramatically reduced for smaller central IMBH and large density of DM. For the central IMBH with 105 M⊙ , the time of merger is ahead, which can be distinguished by LISA, Taiji and Tianqin. We focus on the effect of accretion and compare it with that of gravitational pull and friction. We find that the accretion mass is a small quantity compared to the initial mass of the small BH and the accretion effect is inconspicuous compared with friction. However, the accumulated phase shift caused by accretion is large enough to be detected by LISA, Taiji, and Tianqin, which indicate that the accretion effect can not be ignored in the detection of GWs.
Aloisio, Michelangelo; Bortot, Barbara; Gandin, Ilaria; Severini, Giovanni Maria; Athanasakis, Emmanouil
2017-02-01
Chimerism status evaluation of post-allogeneic hematopoietic stem cell transplantation samples is essential to predict post-transplant relapse. The most commonly used technique capable of detecting small increments of chimerism is quantitative real-time PCR. Although this method is already used in several laboratories, previously described protocols often lack sensitivity and the amount of the DNA required for each chimerism analysis is too high. In the present study, we compared a novel semi-nested allele-specific real-time PCR (sNAS-qPCR) protocol with our in-house standard allele-specific real-time PCR (gAS-qPCR) protocol. We selected two genetic markers and analyzed technical parameters (slope, y-intercept, R2, and standard deviation) useful to determine the performances of the two protocols. The sNAS-qPCR protocol showed better sensitivity and precision. Moreover, the sNAS-qPCR protocol requires, as input, only 10 ng of DNA, which is at least 10-fold less than the gAS-qPCR protocols described in the literature. Finally, the proposed sNAS-qPCR protocol could prove very useful for performing chimerism analysis with a small amount of DNA, as in the case of blood cell subsets.
Aposematism in Archips cerasivoranus not linked to the sequestration of host-derived cyanide.
Fitzgerald, T D; Stevens, M A; Miller, S; Jeffers, P
2008-10-01
This study addressed the question of how caterpillars of Archips cerasivoranus feeding upon Prunus virginiana cope with the cyanogenic compounds of their food. Analysis by ion chromatography showed that young and aged leaves of P. virginiana consumed by the caterpillars during spring have hydrogen cyanide potentials (HCN-ps) of 2,473 +/- 130 ppm and 1,058 +/- 98 ppm, respectively. Although less than 3% of the cyanide released as the caterpillars feed escapes into the atmosphere, the larva's bright-yellow aposematic coloration and conspicuous activity can not be attributed to the sequestration of cyanide. Only six of 25 samples of the caterpillars' defensive regurgitants collected from 12 field colonies contained cyanide (17.6 +/- 6.54 ppm), less than 5% of the quantity previously reported to occur in the regurgitant of the tent caterpillar M. americanum. Only seven of 13 caterpillars assayed had detectable quantities of cyanide in their bodies (3.9 +/- 0.9 ppm). The fecal pellets that encase the cocoon contained no cyanide, nor did the frass that litters the leaf shelters. The small quantities of cyanide that occur in the caterpillar compared to the HCN-p of ingested plant material appear attributable to paced bouts of feeding and the maintenance of a highly alkaline foregut that inhibits cyanogenesis.
Measurement of beta-amyloid peptides in specific cells using a photo thin-film transistor
NASA Astrophysics Data System (ADS)
Kim, Chang-Beom; Chae, Cheol-Joo; Shin, Hye-Rim; Song, Ki-Bong
2012-01-01
The existence of beta-amyloid [Aβ] peptides in the brain has been regarded as the most archetypal biomarker of Alzheimer's disease [AD]. Recently, an early clinical diagnosis has been considered a great importance in identifying people who are at high risk of AD. However, no microscale electronic sensing devices for the detection of Aβ peptides have been developed yet. In this study, we propose an effective method to evaluate a small quantity of Aβ peptides labeled with fluorescein isothiocyanate [FITC] using a photosensitive field-effect transistor [p-FET] with an on-chip single-layer optical filter. To accurately evaluate the quantity of Aβ peptides within the cells cultured on the p-FET device, we measured the photocurrents which resulted from the FITC-conjugated Aβ peptides expressed from the cells and measured the number of photons of the fluorochrome in the cells using a photomultiplier tube. Thus, we evaluated the correlation between the generated photocurrents and the number of emitted photons. We also evaluated the correlation between the number of emitted photons and the amount of FITC by measuring the FITC volume using AFM. Finally, we estimated the quantity of Aβ peptides of the cells placed on the p-FET sensing area on the basis of the binding ratio between FITC molecules and Aβ peptides.
Rakesh Minocha; Walter C. Shortle
1993-01-01
Two simple and fast methods for the extraction of major inorganic cations (Ca, Mg, Mn, K) from small quantities of stemwood and needles of woody plants were developed. A 3.2- or 6.4-mm cobalt drill bit was used to shave samples from disks and increment cores of stemwood. For ion extraction, wood (ground or shavings) or needles were either homogenzied using a Tekmar...
NASA Astrophysics Data System (ADS)
Chang, Fu-Yu; Chen, Ming-Kun; Wang, Min-Haw; Jang, Ling-Sheng
2016-02-01
Cell impedance analysis is widely used for monitoring biological and medical reactions. In this study, a highly sensitive three-dimensional (3D) interdigitated microelectrode (IME) with a high aspect ratio on a polyimide (PI) flexible substrate was fabricated for microparticle detection (e.g. cell quantity detection) using electroforming and lithography technology. 3D finite element simulations were performed to compare the performance of the 3D IME (in terms of sensitivity and signal-to-noise ratio) to that of a planar IME for particles in the sensing area. Various quantities of particles were captured in Dulbecco’s modified Eagle medium and their impedances were measured. With the 3D IME, the particles were arranged in the gap, not on the electrode, avoiding the noise due to particle position. For the maximum particle quantities, the results show that the 3D IME has at least 5-fold higher sensitivity than that of the planar IME. The trends of impedance magnitude and phase due to particle quantity were verified using the equivalent circuit model. The impedance (1269 Ω) of 69 particles was used to estimate the particle quantity (68 particles) with 98.6% accuracy using a parabolic regression curve at 500 kHz.
Prince, Linda M
2015-01-01
Inter-simple sequence repeat PCR (ISSR-PCR) is a fast, inexpensive genotyping technique based on length variation in the regions between microsatellites. The method requires no species-specific prior knowledge of microsatellite location or composition. Very small amounts of DNA are required, making this method ideal for organisms of conservation concern, or where the quantity of DNA is extremely limited due to organism size. ISSR-PCR can be highly reproducible but requires careful attention to detail. Optimization of DNA extraction, fragment amplification, and normalization of fragment peak heights during fluorescent detection are critical steps to minimizing the downstream time spent verifying and scoring the data.
Polonium-210 analyses of vegetables, cured and uncured tobacco, and associated soils.
Berger, K C; Erhardt, W H; Francis, C W
1965-12-24
Analysis of the edible portion of vegetables and samples of green leaf tobacco failed to show polonium-210. The cured samples of leaf tobacco and the soils that were analyzed all contained small quantities of the element. Muck soils contained three times as much Po(210) as did mineral soils. Solutions used commonly to extract "available" forms of many mineral elements failed to extract a detectable amount of Po(2l0). Indications are that Po(210) or its radioactive precursors are not taken up from the soil directly by plant roots but rather by sorption in dead, moist plant materials at the atmosphere-plant interface.
Falling Behind: International Scrutiny of the Peaceful Atom
2008-02-01
confused with critical masses .5 Significant quantity values currently in use by the IAEA are given in Table 1. In a previous Natural Resources... actinides and fission products would not add significantly to the plutonium mass , the state could divert the spiked plutonium to a small clandestine...and manufacturing processes and should not be 152 confused with critical masses . Significant quantities are used in establishing the quantity
Detection of low amount of irradiated ingredients in non-irradiated precooked meals
NASA Astrophysics Data System (ADS)
Marchioni, Eric; Horvatovich, Peter; Ndiaye, Bara; Miesch, Michel; Hasselmann, Claude
2002-03-01
The application of the European Standards for the detection of irradiated food by thermoluminescence of silicates, electron-spin resonance spectroscopy of bones or gas chromatography-mass spectrometry of 2-alkylcyclobutanones does not allow the detection of irradiated ingredients included in small quantity in the matrix of a food which has not been irradiated, but which could be subjected to various processing technologies such as cooking, freezing or storage. The use of an enzymatic food hydrolysis carried out at moderated temperature, for the extraction of the food-contaminating silicate minerals and bone fragments, followed by a purification of the extracts by a high-density aqueous solution of sodium polytungstate, allows a simultaneous detection of weak inclusions (0.1% m:m) of irradiated spices and mechanically deboned turkey meat (MRM) included in various precooked foods. Moreover, the use of a supercritical fluid extraction procedure for the 2-alkylcyclobutanones or an additional purification step of the lipid extracts made it possible to lower the detection limit of the 2-alkylcyclobutanones radiation-induced from triglycerides. Using gas chromatography-mass spectrometry, down to 0.5% (m:m) of irradiated MRM included in non-irradiated chicken quenelles could be detected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richman, D.D.; Cleveland, P.H.; Oxman, M.N.
1981-05-01
A sensitive radioimmunoassay for serum antibody to varicella-zoster virus is described; it uses 125I-labeled staphylococcal protein A and a specially designed immunofiltration apparatus. The assay accurately distinguishes between individuals who are susceptible and those who are immune to infection with varicella-zoster virus. In addition, it can detect passive antibody in recipients of varicella-zoster immune globulin. This radioimmunoassay also detects the heterologous antibody responses that occasionally occur in patients infected with herpes simplex virus, which also have been detected by other antibody assays. The particular advantages of this assay are the use of noninfectious reagents, the speed of execution (less thanmore » 3 hr), the requirement for only small quantities of serum (30 microliters), the objectivity of end-point determination, and the capability of screening large numbers of sera. Consequently, this radioimmunoassay is especially useful for the rapid identification of susceptible individuals, which is essential for the appropriate management of patients and hospital personnel after exposure to varicella.« less
Cell sorting using efficient light shaping approaches
NASA Astrophysics Data System (ADS)
Bañas, Andrew; Palima, Darwin; Villangca, Mark; Glückstad, Jesper
2016-03-01
Early detection of diseases can save lives. Hence, there is emphasis in sorting rare disease-indicating cells within small dilute quantities such as in the confines of lab-on-a-chip devices. In our work, we use optical forces to isolate red blood cells detected by machine vision. This approach is gentler, less invasive and more economical compared to conventional FACS systems. As cells are less responsive to plastic or glass beads commonly used in the optical manipulation literature, and since laser safety would be an issue in clinical use, we develop efficient approaches in utilizing lasers and light modulation devices. The Generalized Phase Contrast (GPC) method that can be used for efficiently illuminating spatial light modulators or creating well-defined contiguous optical traps is supplemented by diffractive techniques capable of integrating the available light and creating 2D or 3D beam distributions aimed at the positions of the detected cells. Furthermore, the beam shaping freedom provided by GPC can allow optimizations in the beam's propagation and its interaction with the catapulted cells.
PELAN: a pulsed neutron portable probe for UXO and land mine identification
NASA Astrophysics Data System (ADS)
Vourvopoulos, George; Womble, Phillip C.; Paschal, Jonathon
2000-12-01
There has been much work increasing the sensitivity of detecting metallic objects in soils and other environments. This has lead to a problem in discriminating unexploded ordnance (UXO) and landmines form other metallic clutter. PELAN is a small portable system for the detection of explosives. PELAN weights less than 45 kg and is man portable. It is based on the principle that explosives and other contraband contain various chemical elements such as H, C, N, O, etc. in quantities and ratios that differentiate them from other innocuous substances. The pulsed neutrons are produced with a 14 MeV neutron generator. Separate gamma-ray spectra form fast neutron, thermal neutron and activation reactions are accumulated and analyzed to determine elemental content. The data analysis is performed in an automatic manner and a result of whether a threat is present is returned to the operator. PELAN has successfully undergone field demonstrations for explosive detection. In this paper, we will discuss the application of PELAN to the problem of differentiating threats from metallic clutter.
Selenium Treatment Technologies
Selenium (Se) is a metalloid that is a dietary requirement in small quantities, but toxic at higher quantities. It also is known to bioaccumulate. In oxic environments, it exists as selenate (+6) and selenite (+4), both of which are soluble. Selenite will sorb more strongly to...
Oh, Seo Young; Kim, Wook Youn; Hwang, Tae Sook; Han, Hye Seung; Lim, So Dug; Kim, Wan Seop
2013-01-01
DNA extraction from microdissected cells has become essential for handling clinical specimens with advances in molecular pathology. Conventional methods have limitations for extracting amplifiable DNA from specimens containing a small number of cells. We developed an ammonium sulfate DNA extraction method (A) and compared it with two other methods (B and C). DNA quality and quantity, β-globin amplification, and detectability of two cancer associated gene mutations were evaluated. Method A showed the best DNA yield, particularly when the cell number was very low. Amplification of the β-globin gene using DNA from the SNU 790 cell line and papillary thyroid carcinoma (PTC) cells extracted with Method A demonstrated the strongest band. BRAF V600E mutation analysis using ethanol-fixed PTC cells from a patient demonstrated both a “T” peak increase and an adjacent “A” peak decrease when 25 and 50 cells were extracted, whereas mutant peaks were too low to be analyzed using the other two methods. EGFR mutation analysis using formalin-fixed paraffin-embedded lung cancer tissues demonstrated a mutant peak with Method A, whereas the mutant peak was undetectable with Methods B or C. Method A yielded the best DNA quantity and quality with outstanding efficiency, particularly when paucicellular specimens were used. PMID:23691506
Special nuclear material simulation device
Leckey, John H.; DeMint, Amy; Gooch, Jack; Hawk, Todd; Pickett, Chris A.; Blessinger, Chris; York, Robbie L.
2014-08-12
An apparatus for simulating special nuclear material is provided. The apparatus typically contains a small quantity of special nuclear material (SNM) in a configuration that simulates a much larger quantity of SNM. Generally the apparatus includes a spherical shell that is formed from an alloy containing a small quantity of highly enriched uranium. Also typically provided is a core of depleted uranium. A spacer, typically aluminum, may be used to separate the depleted uranium from the shell of uranium alloy. A cladding, typically made of titanium, is provided to seal the source. Methods are provided to simulate SNM for testing radiation monitoring portals. Typically the methods use at least one primary SNM spectral line and exclude at least one secondary SNM spectral line.
Integrated digital error suppression for improved detection of circulating tumor DNA
Kurtz, David M.; Chabon, Jacob J.; Scherer, Florian; Stehr, Henning; Liu, Chih Long; Bratman, Scott V.; Say, Carmen; Zhou, Li; Carter, Justin N.; West, Robert B.; Sledge, George W.; Shrager, Joseph B.; Loo, Billy W.; Neal, Joel W.; Wakelee, Heather A.; Diehn, Maximilian; Alizadeh, Ash A.
2016-01-01
High-throughput sequencing of circulating tumor DNA (ctDNA) promises to facilitate personalized cancer therapy. However, low quantities of cell-free DNA (cfDNA) in the blood and sequencing artifacts currently limit analytical sensitivity. To overcome these limitations, we introduce an approach for integrated digital error suppression (iDES). Our method combines in silico elimination of highly stereotypical background artifacts with a molecular barcoding strategy for the efficient recovery of cfDNA molecules. Individually, these two methods each improve the sensitivity of cancer personalized profiling by deep sequencing (CAPP-Seq) by ~3 fold, and synergize when combined to yield ~15-fold improvements. As a result, iDES-enhanced CAPP-Seq facilitates noninvasive variant detection across hundreds of kilobases. Applied to clinical non-small cell lung cancer (NSCLC) samples, our method enabled biopsy-free profiling of EGFR kinase domain mutations with 92% sensitivity and 96% specificity and detection of ctDNA down to 4 in 105 cfDNA molecules. We anticipate that iDES will aid the noninvasive genotyping and detection of ctDNA in research and clinical settings. PMID:27018799
Current trends in endotoxin detection and analysis of endotoxin-protein interactions.
Dullah, Elvina Clarie; Ongkudon, Clarence M
2017-03-01
Endotoxin is a type of pyrogen that can be found in Gram-negative bacteria. Endotoxin can form a stable interaction with other biomolecules thus making its removal difficult especially during the production of biopharmaceutical drugs. The prevention of endotoxins from contaminating biopharmaceutical products is paramount as endotoxin contamination, even in small quantities, can result in fever, inflammation, sepsis, tissue damage and even lead to death. Highly sensitive and accurate detection of endotoxins are keys in the development of biopharmaceutical products derived from Gram-negative bacteria. It will facilitate the study of the intermolecular interaction of an endotoxin with other biomolecules, hence the selection of appropriate endotoxin removal strategies. Currently, most researchers rely on the conventional LAL-based endotoxin detection method. However, new methods have been and are being developed to overcome the problems associated with the LAL-based method. This review paper highlights the current research trends in endotoxin detection from conventional methods to newly developed biosensors. Additionally, it also provides an overview of the use of electron microscopy, dynamic light scattering (DLS), fluorescence resonance energy transfer (FRET) and docking programs in the endotoxin-protein analysis.
The detection of large deletions or duplications in genomic DNA.
Armour, J A L; Barton, D E; Cockburn, D J; Taylor, G R
2002-11-01
While methods for the detection of point mutations and small insertions or deletions in genomic DNA are well established, the detection of larger (>100 bp) genomic duplications or deletions can be more difficult. Most mutation scanning methods use PCR as a first step, but the subsequent analyses are usually qualitative rather than quantitative. Gene dosage methods based on PCR need to be quantitative (i.e., they should report molar quantities of starting material) or semi-quantitative (i.e., they should report gene dosage relative to an internal standard). Without some sort of quantitation, heterozygous deletions and duplications may be overlooked and therefore be under-ascertained. Gene dosage methods provide the additional benefit of reporting allele drop-out in the PCR. This could impact on SNP surveys, where large-scale genotyping may miss null alleles. Here we review recent developments in techniques for the detection of this type of mutation and compare their relative strengths and weaknesses. We emphasize that comprehensive mutation analysis should include scanning for large insertions and deletions and duplications. Copyright 2002 Wiley-Liss, Inc.
Thermodynamics of quantum systems with multiple conserved quantities
Guryanova, Yelena; Popescu, Sandu; Short, Anthony J.; Silva, Ralph; Skrzypczyk, Paul
2016-01-01
Recently, there has been much progress in understanding the thermodynamics of quantum systems, even for small individual systems. Most of this work has focused on the standard case where energy is the only conserved quantity. Here we consider a generalization of this work to deal with multiple conserved quantities. Each conserved quantity, which, importantly, need not commute with the rest, can be extracted and stored in its own battery. Unlike the standard case, in which the amount of extractable energy is constrained, here there is no limit on how much of any individual conserved quantity can be extracted. However, other conserved quantities must be supplied, and the second law constrains the combination of extractable quantities and the trade-offs between them. We present explicit protocols that allow us to perform arbitrarily good trade-offs and extract arbitrarily good combinations of conserved quantities from individual quantum systems. PMID:27384384
Expression of pleiotrophin in small cell lung cancer.
Wang, H Q; Wang, J
2015-01-01
Pleiotrophin (PTN) is a kind of heparin binding growth factor closely related to tumor progression. This study aimed to discuss the significance of the expression of PTN in benign and malignant lung cancer tissues, especially small cell lung cancer. Lung cancer samples were collected for study and lung tissue samples with benign lesions were taken as controls. The expression of PTN was detected using tissue chip combined with the immunohistochemical method, and the differences of small cell lung cancer with non-small cell lung cancer and benign lesion tissue were compared. It was found that PTN expression was mainly located in the cytoplasm and membrane of cells; PTN expression in the lung cancer group was higher than that in the control group (p < 0.01), and PTN expression in the small cell cancer group was higher than that in the squamous carcinoma group and glandular cancer group (p < 0.05). In addition, PTN expression quantity in patients with lung cancer were in close correlation with TNM staging, pathological type and tumor differentiation degree (p < 0.05). PTN was found to express abnormally high in lung cancer, especially small cell lung cancer tissue. PTN is most likely to be a new tumor marker for diagnosis and prognosis of lung cancer.
Dornbos, D L; Spencer, G F
1990-02-01
A large variety of secondary metabolites that can inhibit germination and/or seedling growth are produced by plants in low quantities. The objective of this study was to develop a bioassay capable of reliably assessing reductions in germination percentage and seedling length of small-seeded plant species caused by exposure to minute quantities of these compounds. The germination and growth of alfalfa (Medicago saliva), annual ryegrass (Lolium multiflorum), and velvetleaf (Abutilon theophrasti) were evaluated against six known phytotoxins from five chemical classes; cinmethylin (a herbicidal cineole derivative) was selected as a comparison standard. Each phytotoxin, dissolved in a suitable organic solvent, was placed on water-agar in small tissue culture wells. After the solvent evaporated, imbibed seeds were placed on the agar; after three days, germination percentages and seedling lengths were measured. Compared to a commonly used filter paper procedure, this modified agar bioassay required smaller quantities of compound per seed for comparable bioassay results. This bioassay also readily permitted the measurement of seedling length, a more sensitive indicator of phytotoxicity than germination. Seedling length decreased sigmoidally as the toxin concentration increased logarithmically. Phytotoxicity was a function of both compound and plant species. Cinmethylin, a grass herbicide, reduced the length of annual ryegrass seedlings by 90-100%, whereas that of alfalfa and velvetleaf was inhibited slightly. The agar bioassay facilitated the rapid and reliable testing of slightly water-soluble compounds, requiring only minute quantities of each compound to give reproducible results.
Rapid isolation of mycoviral double-stranded RNA from Botrytis cinerea and Saccharomyces cerevisiae.
Castillo, Antonio; Cottet, Luis; Castro, Miguel; Sepúlveda, Felipe
2011-01-25
In most of the infected fungi, the mycoviruses are latent or cryptic, the infected fungus does not show disease symptoms, and it is phenotypically identical to a non-infected strain of the same species. Because of these properties, the initial stage in the search for fungi infected with mycoviruses is the detection of their viral genome, which in most of the described cases corresponds to double-stranded RNA (dsRNA). So to analyze a large number of fungal isolates it is necessary to have a simple and rapid method to detect dsRNA. A rapid method to isolate dsRNA from a virus-infected filamentous fungus, Botrytis cinerea, and from a killer strain of Saccharomyces cerevisiae using commercial minicolumns packed with CF11 cellulose was developed. In addition to being a rapid method, it allows to use small quantities of yeasts or mycelium as starting material, being obtained sufficient dsRNA quantity that can later be analyzed by agarose gel electrophoresis, treated with enzymes for its partial characterization, amplified by RT-PCR and cloned in appropriate vectors for further sequencing. The method yields high quality dsRNA, free from DNA and ssRNA. The use of nucleases to degrade the DNA or the ssRNA is not required, and it can be used to isolate dsRNA from any type of fungi or any biological sample that contains dsRNA.
Interpretation; Apollo 9 photography of parts of southern Arizona and southern New Mexico
Owen, J. Robert; Shown, Lynn M.
1973-01-01
Examination of small-scale (approximately 1:650,000) multispectral photographs obtained on the Apollo 9 mission in March 1969 revealed that in semiarid, regions features due to differences in soils or quantity of vegetation could most easily be discriminated on the color infrared photographs. Where there is sufficient ground truth, it is possible to delineate regional wildland plant communities on the basis of tone, however, the precision of the method may be improved by using photographs obtained two or more times during the year. Sites where vegetation-improvement practices have been completed are not always discernible. For example, where waterspreaders have been constructed, there was sufficient change in the density of vegetation to be readily detected on the photographs; however, pinyon-juniper to grass, conversions or contour furrowing did not always produce a sufficient change in the vegetation to be detected on the photographs.
Plunkett, S E; Jonas, R E; Braiman, M S
1997-01-01
We have used miniature planar IR waveguides, consisting of Ge strips 30-50 microm thick and 2 mm wide, as evanescent-wave sensors to detect the mid-(IR) evanescent-wave absorbance spectra of small areas of biomolecular monolayers and multilayers. Examples include picomolar quantities of an integral transmembrane protein (bacteriorhodopsin) and lipid (dimyristoyl phosphatidylcholine). IR bands due to the protein and lipid components of the plasma membrane of individual 1.5-mm-diameter devitellinized Xenopus laevis oocytes, submerged in buffer and sticking to the waveguide surface, were also detected. A significant improvement in sensitivity was observed, as compared to previous sizes and geometries of evanescent-wave sensors (e.g., commercially available internal reflection elements or tapered optical fibers). These measurements suggest the feasibility of using such miniature supported planar IR waveguides to observe structural changes in transmembrane proteins functioning in vivo in single cells. PMID:9336219
NASA Astrophysics Data System (ADS)
Lee, Jeong-Eun; Sanyal, Bhaskar; Akram, Kashif; Jo, Yunhee; Baek, Ji-Yeong; Kwon, Joong-Ho
2017-05-01
Thermoluminescence (TL) analysis was conducted to identify small quantities (0.5%, 1%, and 1.5%) of γ ray-or electron beam-irradiated garlic powder in a soy sauce after commercial pasteurization. The sauce samples with γ ray- and electron beam-irradiated (0, 1 or 10 kGy) garlic powder showed detectable TL glow curves, characterized by radiation-induced maximum in the temperature range of 180-225 °C. The successful identification of soy sauces with an irradiation history was dependent on both the mixing ratio of the irradiated ingredient and the irradiation dose. Post-irradiation pasteurization (85 °C, 30 min) caused no considerable changes in TL glow shape or intensity. Interlaboratory tests demonstrated that the shape and intensity of the first TL glow curve (TL1) could be a better detection marker than a TL ratio (TL1/TL2).
Phytochrome-Mediated Detection of Changes in Reflected Light
Mancinelli, Alberto L.
1991-01-01
Measurements of phytochrome photoequilibria and photoconversion rates in vivo, in seedlings of Cucurbita pepo L. exposed to light in growth chambers, indicate that significant changes in the state of phytochrome can be brought about by changes in the quality and quantity of the light reflected from the walls of the growth chambers. The changes in reflected light, although large, were small in terms of the total radiation (direct light from the lamps plus wall-reflected light) to which the seedlings were exposed. The conditions used were approximate simulations of direct and reflected sunlight conditions in the natural environment. Keeping in mind the limitations imposed by the approximation of the simulations, the results from this study are consistent with the hypothesis that, in the natural environment, a plant might be capable of detecting the presence of nearby plants, before being shaded by them, through the phytochrome-mediated perception of changes in reflected light. PMID:16667942
Tornes, L.H.; Brigham, M.E.
1994-01-01
A relatively large fraction of stream samples had detectable quantities of 2,4-D, a- and y-HCH, and atrazine. These samples covered time spans of as much as 15 years and were from sites downstream from large drainage basins; however, concentrations were well below US EPA MCLs. One county-level study showed higher 2,4-D concentrations at upstream sites than at the outlet from a small basin. This indicates that downstream sites may fail to show impaired water-quality and the fate of pesticides used in the basin. Following the 1972 ban on DDT, concentrations of DDT in fish samples from the Red River of the North quickly decreased. Fish concentrations of DDE and DDD decreased more slowly. Low levels of DDE and DDD were detected in fish 14 years after the DDT ban.
77 FR 28259 - Mailings of Lithium Batteries
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
... containing lithium metal or lithium-ion cells or batteries and applies regardless of quantity, size, watt... ``lithium content'' for secondary lithium-ion batteries when describing maximum quantity limits. In addition...-ion (Rechargeable) Cells and Batteries [Revise 10.20.6 as follows:] Small consumer-type lithium-ion...
Madic, Jordan; Remon, Jordi; Honoré, Aurélie; Girard, Romain; Rouleau, Etienne; André, Barbara; Besse, Benjamin; Droniou, Magali; Lacroix, Ludovic
2017-01-01
Over the past years, targeted therapies using tyrosine kinase inhibitors (TKI) have led to an increase in progression-free survival and response rate for a subgroup of non-small cell lung cancer (NSCLC) patients harbouring specific gene abnormalities compared with chemotherapy. However long-lasting tumor regression is rarely achieved, due to the development of resistant tumoral subclones, which requires alternative therapeutic approaches. Molecular profile at progressive disease is a challenge for making adaptive treatment decisions. The aim of this study was to monitor EGFR-mutant tumors over time based on the quantity of mutant DNA circulating in plasma (ctDNA), comparing two different methods, Crystal™ Digital™ PCR and Massive Parallel Sequencing (MPS). In plasma circulating cell free DNA (cfDNA) of 61 advanced NSCLC patients we found an overall correlation of 78% between mutated allelic fraction measured by Crystal Digital PCR and MPS. 7 additional samples with sensitizing mutations and 4 additional samples with the resistance mutation were detected with Crystal Digital PCR, but not with MPS. Monitoring levels of both mutation types over time showed a correlation between levels and trends of mutated ctDNA detected and clinical assessment of disease for the 6 patients tested. In conclusion, Crystal Digital PCR exhibited good performance for monitoring mutational status in plasma cfDNA, and also appeared as better suited to the detection of known mutations than MPS in terms of features such as time to results. PMID:28829811
Li, Yong; Cai, Rui; Yan, Bei; Zainal Abidin, Ilham Mukriz; Jing, Haoqing; Wang, Yi
2018-05-28
For fuel transmission and structural strengthening, small-diameter pipes of nonmagnetic materials are extensively adopted in engineering fields including aerospace, energy, transportation, etc. However, the hostile and corrosive environment leaves them vulnerable to external corrosion which poses a severe threat to structural integrity of pipes. Therefore, it is imperative to nondestructively detect and evaluate the external corrosion in nonmagnetic pipes. In light of this, a capsule-type Electromagnetic Acoustic Transducer (EMAT) for in-situ nondestructive evaluation of nonmagnetic pipes and fast screening of external corrosion is proposed in this paper. A 3D hybrid model for efficient prediction of responses from the proposed transducer to external corrosion is established. Closed-form expressions of field quantities of electromagnetics and EMAT signals are formulated. Simulations based on the hybrid model indicate feasibility of the proposed transducer in detection and evaluation of external corrosion in nonmagnetic pipes. In parallel, experiments with the fabricated transducer have been carried out. Experimental results are supportive of the conclusion drawn from simulations. The investigation via simulations and experiments implies that the proposed capsule-type EMAT is capable of fast screening of external corrosion, which is beneficial to the in-situ nondestructive evaluation of small-diameter nonmagnetic pipes.
Principles and Applications of the qPlus Sensor
NASA Astrophysics Data System (ADS)
Giessibl, Franz J.
The concept of the atomic force microscope (AFM) is a very simple one: map the surface of a sample by a sharp probe that scans over the surface similar to the finger of a blind person that reads Braille characters. In AFM, the role of that finger is taken by the probe tip that senses the presence of the sample surface by detecting the force between the tip of the probe and a sample. The qPlus sensor is a self sensing cantilever based on a quartz tuning fork that supplements the traditional microfabricated cantilevers made of silicon. Quartz tuning forks are used in the watch industry in quantities of billions annually, with the positive effects on quality and perfection. Three properties of these quartz-based sensors simplify the AFM significantly: (1) the piezoelectricity of quartz allows simple self sensing, (2) the mechanical properties of quartz show very small variations with temperature, and (3) the given stiffness of many quartz tuning forks is close to the ideal stiffness of cantilevers. The key properties of the qPlus sensor are a large stiffness that allows small amplitude operation, the large size that allows to mount single-crystal probe tips, and the self-sensing piezoelectric detection mechanism.
Akamatsu, Masaaki; Mori, Taizo; Okamoto, Ken; Komatsu, Hirokazu; Kumagai, Ken; Shiratori, Seimei; Yamamura, Masaki; Nabeshima, Tatsuya; Sakai, Hideki; Abe, Masahiko; Hill, Jonathan P; Ariga, Katsuhiko
2015-03-25
An alcohol sensor was developed using the solid-state fluorescence emission of terphenyl-ol (TPhOH) derivatives. Admixtures of TPhOH and sodium carbonate exhibited bright sky-blue fluorescence in the solid state upon addition of small quantities of ethanol. A series of terphenol derivatives was synthesized, and the effects of solvent polarities and the structures of these π-conjugated systems on their fluorescence were systematically investigated by using fluorescence spectroscopy. In particular, π-extended TPhOHs and TPhOHs containing electron-withdrawing groups exhibited significant solvatochromism, and fluorescence colors varied from blue to red. Detection of ethanol contents in alcohol beverages (detection limit ∼ 5 v/v %) was demonstrated using different TPhOHs revealing the effect of molecular structure on sensing properties. Ethanol contents in alcoholic beverages could be estimated from the intensity of the fluorescence elicited from the TPhOHs. Moreover, when terphenol and Na2CO3 were combined with a water-absorbent polymer, ethanol could be detected at lower concentrations. Detection of ethanol vapor (8 v/v % in air) was also accomplished using a nanofibrous polymer scaffold as the immobilized sensing film.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunschel, David S.; Colburn, Heather A.; Fox, Alvin
2008-08-01
Detection of small quantities of agar associated with spores of Bacillus anthracis could provide key information regarding its source or growth characteristics. Agar, widely used in growth of bacteria on solid surfaces, consists primarily of repeating polysaccharide units of 3,6-anhydro-L-galactose (AGal) and galactose (Gal) with sulfated and O-methylated galactoses present as minor constituents. Two variants of the alditol acetate procedure were evaluated for detection of potential agar markers associated with spores. The first method employed a reductive hydrolysis step, to stabilize labile anhydrogalactose, by converting to anhydrogalactitol. The second eliminated the reductive hydrolysis step simplifying the procedure. Anhydrogalactitol, derived frommore » agar, was detected using both derivatization methods followed by gas chromatography-mass spectrometry (GC-MS) analysis. However, challenges with artefactual background (reductive hydrolysis) or marker destruction (hydrolysis) lead to the search for alternative sugar markers. A minor agar component, 6-O-methyl galactose (6-O-M gal), was readily detected in agar-grown but not broth-grown bacteria. Detection was optimized by the use of gas chromatography-tandem mass spectrometry (GC-MS-MS). With appropriate choice of sugar marker and analytical procedure, detection of sugar markers for agar has considerable potential in microbial forensics.« less
Sakai, Kaori; Taconnat, Ludivine; Borrega, Nero; Yansouni, Jennifer; Brunaud, Véronique; Paysant-Le Roux, Christine; Delannoy, Etienne; Martin Magniette, Marie-Laure; Lepiniec, Loïc; Faure, Jean Denis; Balzergue, Sandrine; Dubreucq, Bertrand
2018-01-01
Genome-wide characterization of tissue- or cell-specific gene expression is a recurrent bottleneck in biology. We have developed a sensitive approach based on ultra-low RNA sequencing coupled to laser assisted microdissection for analyzing different tissues of the small Arabidopsis embryo. We first characterized the number of genes detected according to the quantity of tissue yield and total RNA extracted. Our results revealed that as low as 0.02 mm 2 of tissue and 50 pg of total RNA can be used without compromising the number of genes detected. The optimised protocol was used to compare the epidermal versus mesophyll cell transcriptomes of cotyledons at the torpedo-shaped stage of embryo development. The approach was validated by the recovery of well-known epidermal genes such AtML1 or AtPDF2 and genes involved in flavonoid and cuticular waxes pathways. Moreover, the interest and sensitivity of this approach were highlighted by the characterization of several transcription factors preferentially expressed in epidermal cells. This technical advance unlocks some current limitations of transcriptomic analyses and allows to investigate further and efficiently new biological questions for which only a very small amounts of cells need to be isolated. For instance, it paves the way to increasing the spatial accuracy of regulatory networks in developing small embryo of Arabidopsis or other plant tissues.
Foster, Stephen P; Anderson, Karin G; Casas, Jérôme
2018-05-10
Moths are exemplars of chemical communication, especially with regard to specificity and the minute amounts they use. Yet, little is known about how females manage synthesis and storage of pheromone to maintain release rates attractive to conspecific males and why such small amounts are used. We developed, for the first time, a quantitative model, based on an extensive empirical data set, describing the dynamical relationship among synthesis, storage (titer) and release of pheromone over time in a moth (Heliothis virescens). The model is compartmental, with one major state variable (titer), one time-varying (synthesis), and two constant (catabolism and release) rates. The model was a good fit, suggesting it accounted for the major processes. Overall, we found the relatively small amounts of pheromone stored and released were largely a function of high catabolism rather than a low rate of synthesis. A paradigm shift may be necessary to understand the low amounts released by female moths, away from the small quantities synthesized to the (relatively) large amounts catabolized. Future research on pheromone quantity should focus on structural and physicochemical processes that limit storage and release rate quantities. To our knowledge, this is the first time that pheromone gland function has been modeled for any animal.
Koizumi, A; Hamade, N; Arai, M; Takatoku, M; Yasuhiko, W; Tsukada, M; Kamiyama, S
1990-01-01
Phosphoglycerate kinase (PGK, EC 2.7.2.3), which is expressed specifically in sperm and spermatids, is an enzyme in the Embden-Meyerhof pathway that converts glucose to pyruvate. We developed an electrophoresis method to determine relative PGK-2 quantity and applied it to evaluate spermatogenesis activity. In the ethylene glycol monomethyl ether (EGME)-induced testicular toxicity, relative PGK-2 quantity had not decreased until 4 weeks of exposure. Mean relative PGK-2 quantities, defined as PGK-2 quantity over PGK-1 quantity in a pooled spleen sample (+/- SD) were: 1.43 +/- 0.32 for control animals (N = 10); 1.67 +/- 0.24 for the group exposed at 500 mg/kg for 5 days (N = 6); 1.85 +/- 0.58 for the group exposed at 500 mg/kg for 2 weeks (N = 6); 0.09 +/- 0.06 for the group exposed at 500 mg/kg for 4 weeks (N = 6); not detectable in animals exposed at 500 mg/kg for 5 weeks (N = 7); 0.208 +/- 0.103 for the group exposed at 250 mg/kg for 5 weeks (N = 6); and 1.35 +/- 0.38 for the group exposed at 125 mg/kg for 5 weeks (N = 6). These relative quantities showed a good correlation with sperm/spermatid counts (r = 0.823, p less than 0.01) and histological findings. These findings suggest that EGME has toxicity on primary spermatocytes and spermatogonia. In the case of sterility associated with a chromosomal abnormality (chromosomal translocation between chromosome X and 16), relative PGK-2 quantity was not detected in any of the seven adult (12 weeks of age) mice, although many primary spermatocytes were detected by histological examination.(ABSTRACT TRUNCATED AT 250 WORDS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abramczyk, G.
2011-10-31
This Addendum establishes a new family of content envelopes consisting of small quantities of radioactive materials. These content envelopes and specific packing configurations are shown to be subcritical. However, the dose rates of some payloads must be measured and shown to comply with applicable radiation limits. Authorization for shipment of the content envelop requires acceptance of this Addendum by the DOE-HQ certifying official as a supplement to the 9977 SARP Revision 2 and DOE-HQ's subsequent revision of the CoC Revision 10 (which is based on SARP Addendum 2 and SARP Addendum 4) to authorize the additional content envelope. The Smallmore » Gram Quantity Content Envelopes and packing configurations will be incorporated in the next revision of the 9977 SARP.« less
Fu, Glenn K; Wilhelmy, Julie; Stern, David; Fan, H Christina; Fodor, Stephen P A
2014-03-18
We present a new approach for the sensitive detection and accurate quantitation of messenger ribonucleic acid (mRNA) gene transcripts in single cells. First, the entire population of mRNAs is encoded with molecular barcodes during reverse transcription. After amplification of the gene targets of interest, molecular barcodes are counted by sequencing or scored on a simple hybridization detector to reveal the number of molecules in the starting sample. Since absolute quantities are measured, calibration to standards is unnecessary, and many of the relative quantitation challenges such as polymerase chain reaction (PCR) bias are avoided. We apply the method to gene expression analysis of minute sample quantities and demonstrate precise measurements with sensitivity down to sub single-cell levels. The method is an easy, single-tube, end point assay utilizing standard thermal cyclers and PCR reagents. Accurate and precise measurements are obtained without any need for cycle-to-cycle intensity-based real-time monitoring or physical partitioning into multiple reactions (e.g., digital PCR). Further, since all mRNA molecules are encoded with molecular barcodes, amplification can be used to generate more material for multiple measurements and technical replicates can be carried out on limited samples. The method is particularly useful for small sample quantities, such as single-cell experiments. Digital encoding of cellular content preserves true abundance levels and overcomes distortions introduced by amplification.
Wang, Chuji
2009-01-01
Fiber loop ringdown (FLRD) utilizes an inexpensive telecommunications light source, a photodiode, and a section of single-mode fiber to form a uniform fiber optic sensor platform for sensing various quantities, such as pressure, temperature, strain, refractive index, chemical species, biological cells, and small volume of fluids. In FLRD, optical losses of a light pulse in a fiber loop induced by changes in a quantity are measured by the light decay time constants. FLRD measures time to detect a quantity; thus, FLRD is referred to as a time-domain sensing technique. FLRD sensors have near real-time response, multi-pass enhanced high-sensitivity, and relatively low cost (i.e., without using an optical spectral analyzer). During the last eight years since the introduction of the original form of fiber ringdown spectroscopy, there has been increasing interest in the FLRD technique in fiber optic sensor developments, and new application potential is being explored. This paper first discusses the challenging issues in development of multi-function, fiber optic sensors or sensor networks using current fiber optic sensor sensing schemes, and then gives a review on current fiber optic sensor development using FLRD technique. Finally, design perspectives on new generation, multi-function, fiber optic sensor platforms using FLRD technique are particularly presented. PMID:22408471
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishida, Hideshi, E-mail: ishida@me.es.osaka-u.ac.jp
2014-06-15
In this study, a family of local quantities defined on each partition and its averaging on a macroscopic small region, site, are defined on a multibaker chain system. On its averaged quantities, a law of order estimation in the bulk system is proved, making it possible to estimate the order of the quantities with respect to the representative partition scale parameter Δ. Moreover, the form of the leading-order terms of the averaged quantities is obtained, and the form enables us to have the macroscopic quantity in the continuum limit, as Δ → 0, and to confirm its partitioning independency. Thesemore » deliverables fully explain the numerical results obtained by Ishida, consistent with the irreversible thermodynamics.« less
Henderson, Timothy M.; Wuttke, Gilbert H.
1977-01-01
A variable leak gas source and a method for obtaining the same which includes filling a quantity of hollow glass micro-spheres with a gas, storing said quantity in a confined chamber having a controllable outlet, heating said chamber above room temperature, and controlling the temperature of said chamber to control the quantity of gas passing out of said controllable outlet. Individual gas filled spheres may be utilized for calibration purposes by breaking a sphere having a known quantity of a known gas to calibrate a gas detection apparatus.
Yung, Tony K F; Chan, K C Allen; Mok, Tony S K; Tong, Joanna; To, Ka-Fai; Lo, Y M Dennis
2009-03-15
We aim to develop a digital PCR-based method for the quantitative detection of the two common epidermal growth factor receptor (EGFR) mutations (in-frame deletion at exon 19 and L858R at exon 21) in the plasma and tumor tissues of patients suffering from non-small cell lung cancers. These two mutations account for >85% of clinically important EGFR mutations associated with responsiveness to tyrosine kinase inhibitors. DNA samples were analyzed using a microfluidics system that simultaneously performed 9,180 PCRs at nanoliter scale. A single-mutant DNA molecule in a clinical specimen could be detected and the quantities of mutant and wild-type sequences were precisely determined. Exon 19 deletion and L858R mutation were detectable in 6 (17%) and 9 (26%) of 35 pretreatment plasma samples, respectively. When compared with the sequencing results of the tumor samples, the sensitivity and specificity of plasma EGFR mutation analysis were 92% and 100%, respectively. The plasma concentration of the mutant sequences correlated well with the clinical response. Decreased concentration was observed in all patients with partial or complete clinical remission, whereas persistence of mutation was observed in a patient with cancer progression. In one patient, tyrosine kinase inhibitor was stopped after an initial response and the tumor-associated EGFR mutation reemerged 4 weeks after stopping treatment. The sensitive detection and accurate quantification of low abundance EGFR mutations in tumor tissues and plasma by microfluidics digital PCR would be useful for predicting treatment response, monitoring disease progression and early detection of treatment failure associated with acquired drug resistance.
Modality-independent representations of small quantities based on brain activation patterns.
Damarla, Saudamini Roy; Cherkassky, Vladimir L; Just, Marcel Adam
2016-04-01
Machine learning or MVPA (Multi Voxel Pattern Analysis) studies have shown that the neural representation of quantities of objects can be decoded from fMRI patterns, in cases where the quantities were visually displayed. Here we apply these techniques to investigate whether neural representations of quantities depicted in one modality (say, visual) can be decoded from brain activation patterns evoked by quantities depicted in the other modality (say, auditory). The main finding demonstrated, for the first time, that quantities of dots were decodable by a classifier that was trained on the neural patterns evoked by quantities of auditory tones, and vice-versa. The representations that were common across modalities were mainly right-lateralized in frontal and parietal regions. A second finding was that the neural patterns in parietal cortex that represent quantities were common across participants. These findings demonstrate a common neuronal foundation for the representation of quantities across sensory modalities and participants and provide insight into the role of parietal cortex in the representation of quantity information. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Bromhal, G. S.; Wilson, T. H.; Wells, A.; Diehl, R.; Smith, D. H.
2003-12-01
Recently, a few thousand tons of CO2 were injected into the West Pearl Queen field, a depleted oil reservoir in southeastern New Mexico, for a pilot carbon sequestration project. Small amounts of 3 different perfluorocarbon tracers were injected with the CO2. Approximately 50 capillary absorption tube samplers (CATS) were located across the field within 2m of the grounds surface to detect the tracers in extremely small (~10-13L) quantities. After only several days, the CATS detected quantities of tracers at distances of up to 350m from the injection well. Greater amounts of tracers were detected in the different directions. The underground transport mechanism(s) are uncertain; however, appearance of tracer in the CATS after only a 6 day period suggests that CO2 movement may have occurred through near-surface processes. Subsequent tracer measurements made over 10 and 54 day time periods revealed continued tracer leakage. To try to understand the tracer information, we conducted lineament interpretations of the area using a black and white aerial photo taken in 1949, digital orthophotos, and Landsat TM imagery. Lineament interpretations revealed distinct northeast and northwest trending lineament sets. These directions coincided roughly with the direction of tracer-leakage into areas northwest and southwest of the injection well. The near-surface geology consists of a few-feet thick veneer of late Pleistocene and Holocene sand dunes covering the middle Pleistocene Mescalero caliche. A survey of the caliche was made using ground penetrating radar (GPR) to attempt to identify any preferential migration pathways. Modeling studies also were performed to identify the potential leakage pathways at the site. Because of the relatively fast appearance of tracers at large distances from the injection well, simple diffusion through the surface layers was ruled out. Wind patterns in the area have also made transport through the atmosphere and back into the ground highly unlikely. Other potential leakage pathways were transport from the well through the saturated zone and diffusion into the unsaturated zone or combined pressure-driven and diffusive flow through the vadose zone. An analysis of these alternatives has been made for this study.
Locating trace plutonium in contaminated soil using micro-XRF imaging
Worley, Christopher G.; Spencer, Khalil J.; Boukhalfa, Hakim; ...
2014-06-01
Micro-X-ray fluorescence (MXRF) was used to locate minute quantities of plutonium in contaminated soil. Because the specimen had previously been prepared for analysis by scanning electron microscopy, it was coated with gold to eliminate electron beam charging. However, this significantly hindered efforts to detect plutonium by MXRF. The gold L peak series present in all spectra increased background counts. Plutonium signal attenuation by the gold coating and severe peak overlap from potassium in the soil prevented detection of trace plutonium using the Pu Mα peak. However, the 14.3 keV Pu Lα peak sensitivity was not optimal due to poor transmissionmore » efficiency through the source polycapillary optic, and the instrument silicon drift detector sensitivity quickly declines for peaks with energies above ~10 keV. Instrumental parameters were optimized (eg. using appropriate source filters) in order to detect plutonium. An X-ray beam aperture was initially used to image a majority of the specimen with low spatial resolution. A small region that appeared to contain plutonium was then imaged at high spatial resolution using a polycapillary optic. Small areas containing plutonium were observed on a soil particle, and iron was co-located with the plutonium. Zinc and titanium also appeared to be correlated with the plutonium, and these elemental correlations provided useful plutonium chemical state information that helped to better understand its environmental transport properties.« less
THE CELLULAR ORIGIN OF HUMAN IMMUNOGLOBULINS (γ2, γ1M, γ1A)
Mellors, Robert C.; Korngold, Leonhard
1963-01-01
A study was made of the cellular origin of human immunoglobulins (γ2, γ1M, γ1A). The results indicated that two closely related families of cells form immunoglobulins in human lymphoid tissue: germinal (reticular) centers and plasma cells. Thus their cellular origin in addition to their known antigenic relations further justifies placing the immunoglobulins in one family of proteins. Immunoglobulins were also formed to a small extent in primitive reticular cells which resembled those of germinal centers but were separated from them. Possibly such cells were undergoing transition to the much more numerous plasma cells with which they were commonly associated. The mantles of small lymphocytes which surrounded germinal centers did not contain detectable quantities of immunoglobulins. While in general only one type of immunoglobulin was present in an individual cell or germinal center, γ2- and γ1M-globulin were identified on occasion in the same plasma cell and germinal center. A peculiarity of the fetal thymus gland was the presence of immunoglobulin, mainly γ1M, in a small number of cells of small and intermediate size and primitive reticular appearance and in Hassall's corpuscles. PMID:14077999
Bromothymol blue coated fiber optic Fabry-Perot interferometer for ammonia gas sensor
NASA Astrophysics Data System (ADS)
Pawar, Dnyandeo; Mane, S. A.; Kale, S. N.
2017-04-01
A single mode fiber is used in this study, in a Y-coupler mode; the mirror tip of which is coated with bromothymol blue (BTB), homogeneously mixed in polyvinyl alcohol (PVA) matrix. The setup operated at 1550 nm, and was used to sense extremely small quantities of ammonia gas, at room temperature. The sensor is able to detect ammonia in the range of 1.5 ppm to 150 ppm; with observed sensitivity in terms of wavelength shift of 0.7 nm. The sensor showed excellent reversibility with fast response and recovery time of the order of few seconds. The possible interaction of dye with ammonia was studied and compared with chloroform.
Detecting small holes in packages
Kronberg, James W.; Cadieux, James R.
1996-01-01
A package containing a tracer gas, and a method for determining the presence of a hole in the package by sensing the presence of the gas outside the package. The preferred tracer gas, especially for food packaging, is sulfur hexafluoride. A quantity of the gas is added to the package and the package is closed. The concentration of the gas in the atmosphere outside the package is measured and compared to a predetermined value of the concentration of the gas in the absence of the package. A measured concentration greater than the predetermined value indicates the presence of a hole in the package. Measuring may be done in a chamber having a lower pressure than that in the package.
NASA Astrophysics Data System (ADS)
Straub, Jeremy
2017-06-01
Prior work by Zeltmann, et al. has demonstrated the impact of small defects and other irregularities on the structural integrity of 3D printed objects. It posited that such defects could be introduced intentionally. The current work looks at the impact of changing the fill level on object structural integrity. It considers whether the existence of an appropriate level of fill can be determined through visible light imagery-based assessment of a 3D printed object. A technique for assessing the quality and sufficiency of quantity of 3D printed fill material is presented. It is assessed experimentally and results are presented and analyzed.
Platinum/Tin Oxide/Silica Gel Catalyst Oxidizes CO
NASA Technical Reports Server (NTRS)
Upchurch, Billy T.; Davis, Patricia P.; Schryer, David R.; Miller, Irvin M.; Brown, David; Van Norman, John D.; Brown, Kenneth G.
1991-01-01
Heterogeneous catalyst of platinum, tin oxide, and silica gel combines small concentrations of laser dissociation products, CO and O2, to form CO22 during long times at ambient temperature. Developed as means to prevent accumulation of these products in sealed CO2 lasers. Effective at ambient operating temperatures and installs directly in laser envelope. Formulated to have very high surface area and to chemisorb controlled quantities of moisture: chemisorbed water contained within and upon its structure, makes it highly active and very longlived so only small quantity needed for long times.
Transfer of Invasive Species Associated with the Movement of Military Equipment and Personnel
2007-07-01
are examples of each type of violation, and what actions to take upon discovery of the violation. 3.7.1. Petty Violations: 3.7.1.1. Pornographic ...ERDC/EL TR-07-8 64 4.5.2.1. Pornographic magazines 4.5.2.2. A small quantity of an unauthorized war trophy. 4.5.2.3. Ammunition. 4.5.2.4. A...upon discovery of the violation. 5.6.2. Petty Violations: 5.6.2.1. Pornographic magazines 5.6.2.2. A small quantity of an unauthorized war trophy
Lovestead, Tara M; Bruno, Thomas J
2011-01-30
Victims of crimes are often buried in clandestine graves. There are several techniques for finding buried bodies or the scattered remains of a victim; however, none of these methods are very reliable or work in all scenarios. One way to detect gravesoil is to detect the biochemical changes of the surrounding soil due to cadaver decomposition, for example, the release of nitrogenous compounds. A simple and low-cost way to detect these compounds is based on the reaction of alpha amino groups with ninhydrin to form Ruhemann's purple. This test for ninhydrin-reactive nitrogen (NRN) has, to date, only been performed by direct solvent extraction of soil samples. Here, we present a method that detects trace quantities of NRN in the headspace air above gravesoil. Our method is based on an improved purge and trap method developed in our lab for sampling low volatility compounds, as well as volatile compounds at trace quantities, by applying low temperature collection on short alumina-coated porous layer open tubular (PLOT) columns. We modified this method to sample the headspace air above gravesoil with a motorized pipetter and a PLOT column at ambient temperatures. We generated gravesoil using rat cadavers and local soil. Trace quantities of NRN were successfully detected in the headspace air above gravesoil. We report the quantities of NRN recovered for buried rats, rats laid on top of soil, and blank graves (no rats) as a function of time (weeks to months). This work is the first (and thus far, only) example of a method for detecting NRN in the vapor phase, providing another tool for forensic investigators to aid in locating elusive clandestine graves. Published by Elsevier Ireland Ltd.
NASA Astrophysics Data System (ADS)
Lin, Wei; Chen, Yu-hua; Wang, Ji-yuan; Gao, Hong-sheng; Wang, Ji-jun; Su, Rong-hua; Mao, Wei
2011-04-01
Detection probability is an important index to represent and estimate target viability, which provides basis for target recognition and decision-making. But it will expend a mass of time and manpower to obtain detection probability in reality. At the same time, due to the different interpretation of personnel practice knowledge and experience, a great difference will often exist in the datum obtained. By means of studying the relationship between image features and perception quantity based on psychology experiments, the probability model has been established, in which the process is as following.Firstly, four image features have been extracted and quantified, which affect directly detection. Four feature similarity degrees between target and background were defined. Secondly, the relationship between single image feature similarity degree and perception quantity was set up based on psychological principle, and psychological experiments of target interpretation were designed which includes about five hundred people for interpretation and two hundred images. In order to reduce image features correlativity, a lot of artificial synthesis images have been made which include images with single brightness feature difference, images with single chromaticity feature difference, images with single texture feature difference and images with single shape feature difference. By analyzing and fitting a mass of experiments datum, the model quantitys have been determined. Finally, by applying statistical decision theory and experimental results, the relationship between perception quantity with target detection probability has been found. With the verification of a great deal of target interpretation in practice, the target detection probability can be obtained by the model quickly and objectively.
Pailler, Emma; Faugeroux, Vincent; Oulhen, Marianne; Catelain, Cyril
2017-01-01
In non-small cell lung cancer (NSCLC), diagnosis of predictive biomarkers for targeted therapies is currently done in small tumor biopsies. However, tumor biopsies can be invasive, in some cases associated with risk, and tissue adequacy, both in terms of quantity and quality is often insufficient. The development of efficient and non-invasive methods to identify genetic alterations is a key challenge which circulating tumor cells (CTCs) have the potential to be exploited for. CTCs are extremely rare and phenotypically diverse, two characteristics that impose technical challenges and impact the success of robust molecular analysis. Here we introduce the clinical needs in this disease that mainly consist of the diagnosis of epidermal growth factor receptor (EGFR) activating alterations and anaplastic lymphoma kinase (ALK) rearrangement. We present the proof-of-concept studies that explore the detection of these genetic alterations in CTCs from NSCLC patients. Finally, we discuss steps that are still required before CTCs are routinely used for diagnosis of EGFR-mutations and ALK-rearrangements in this disease. PMID:28904888
Pailler, Emma; Faugeroux, Vincent; Oulhen, Marianne; Catelain, Cyril; Farace, Françoise
2017-08-01
In non-small cell lung cancer (NSCLC), diagnosis of predictive biomarkers for targeted therapies is currently done in small tumor biopsies. However, tumor biopsies can be invasive, in some cases associated with risk, and tissue adequacy, both in terms of quantity and quality is often insufficient. The development of efficient and non-invasive methods to identify genetic alterations is a key challenge which circulating tumor cells (CTCs) have the potential to be exploited for. CTCs are extremely rare and phenotypically diverse, two characteristics that impose technical challenges and impact the success of robust molecular analysis. Here we introduce the clinical needs in this disease that mainly consist of the diagnosis of epidermal growth factor receptor ( EGFR ) activating alterations and anaplastic lymphoma kinase ( ALK ) rearrangement. We present the proof-of-concept studies that explore the detection of these genetic alterations in CTCs from NSCLC patients. Finally, we discuss steps that are still required before CTCs are routinely used for diagnosis of EGFR -mutations and ALK -rearrangements in this disease.
7 CFR 17.5 - Contracts between commodity suppliers and importers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... substantial increase in freight costs to the participant; (B) For small quantities offered at additional... purposes of this section, “lowest landed cost” means the combination of commodity price and ocean freight... the quantity which must be shipped on privately owned U.S.-flag commercial vessels, as determined by...
7 CFR 17.5 - Contracts between commodity suppliers and importers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... substantial increase in freight costs to the participant; (B) For small quantities offered at additional... purposes of this section, “lowest landed cost” means the combination of commodity price and ocean freight... the quantity which must be shipped on privately owned U.S.-flag commercial vessels, as determined by...
7 CFR 17.5 - Contracts between commodity suppliers and importers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... substantial increase in freight costs to the participant; (B) For small quantities offered at additional... purposes of this section, “lowest landed cost” means the combination of commodity price and ocean freight... the quantity which must be shipped on privately owned U.S.-flag commercial vessels, as determined by...
7 CFR 17.5 - Contracts between commodity suppliers and importers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... substantial increase in freight costs to the participant; (B) For small quantities offered at additional... purposes of this section, “lowest landed cost” means the combination of commodity price and ocean freight... the quantity which must be shipped on privately owned U.S.-flag commercial vessels, as determined by...
An efficient and sensitive method for preparing cDNA libraries from scarce biological samples
Sterling, Catherine H.; Veksler-Lublinsky, Isana; Ambros, Victor
2015-01-01
The preparation and high-throughput sequencing of cDNA libraries from samples of small RNA is a powerful tool to quantify known small RNAs (such as microRNAs) and to discover novel RNA species. Interest in identifying the small RNA repertoire present in tissues and in biofluids has grown substantially with the findings that small RNAs can serve as indicators of biological conditions and disease states. Here we describe a novel and straightforward method to clone cDNA libraries from small quantities of input RNA. This method permits the generation of cDNA libraries from sub-picogram quantities of RNA robustly, efficiently and reproducibly. We demonstrate that the method provides a significant improvement in sensitivity compared to previous cloning methods while maintaining reproducible identification of diverse small RNA species. This method should have widespread applications in a variety of contexts, including biomarker discovery from scarce samples of human tissue or body fluids. PMID:25056322
Hydrologic conditions at the Idaho National Engineering Laboratory, Idaho, emphasis; 1974-1978
Barraclough, Jack T.; Lewis, Barney D.; Jensen, Rodger G.
1981-01-01
Aqueous chemical and radioactive wastes have been discharged to shallow ponds and to shallow or deep wells on the Idaho National Engineering Laboratory (INEL) since 1952 and has affected the quality of the ground water in the underlying Snake River Plain aquifer. Ongoing studies conducted from 1974 through 1978 have shown the perpetuation of a perched ground-water zone in the basalt underlying the waste disposal ponds at the INEL 's Test Reactor Area and of several waste plumes in the regional aquifer created by deep well disposal at the Idaho Chemical Processing Plant (ICPP). The perched zone contains tritium, chromium-51, cobalt-60, strontium-90, and several nonradioactive chemicals. Tritium has formed the largest waste plume south of the ICPP, and accounts for 95 percent of the total radioacticity disposed of through the ICPP disposal well. Waste plumes with similar configurations and flowpaths contain sodium, chloride, and nitrate. Strontium-90, iodine-129, and cesium-137 are also discharged through the well but they are sorbed from solution as they move through the aquifer or are discharged in very small quantities. Strontium-90 and iodine-129 have formed small waste plumes and cesium-137 is not detectable in ground-water samples. Radionuclide plume size and concentrations therein are controlled by aquifer flow conditions, the quantity discharged, radioactive decay, sorption, dilution by dispersion, and perhaps other chemical reactions. Chemical wastes are subject to the same processes except for radioactive decay. (USGS)
Monte Carlo simulation of induction time and metastable zone width; stochastic or deterministic?
NASA Astrophysics Data System (ADS)
Kubota, Noriaki
2018-03-01
The induction time and metastable zone width (MSZW) measured for small samples (say 1 mL or less) both scatter widely. Thus, these two are observed as stochastic quantities. Whereas, for large samples (say 1000 mL or more), the induction time and MSZW are observed as deterministic quantities. The reason for such experimental differences is investigated with Monte Carlo simulation. In the simulation, the time (under isothermal condition) and supercooling (under polythermal condition) at which a first single crystal is detected are defined as the induction time t and the MSZW ΔT for small samples, respectively. The number of crystals just at the moment of t and ΔT is unity. A first crystal emerges at random due to the intrinsic nature of nucleation, accordingly t and ΔT become stochastic. For large samples, the time and supercooling at which the number density of crystals N/V reaches a detector sensitivity (N/V)det are defined as t and ΔT for isothermal and polythermal conditions, respectively. The points of t and ΔT are those of which a large number of crystals have accumulated. Consequently, t and ΔT become deterministic according to the law of large numbers. Whether t and ΔT may stochastic or deterministic in actual experiments should not be attributed to change in nucleation mechanisms in molecular level. It could be just a problem caused by differences in the experimental definition of t and ΔT.
Nebulization Reflux Concentrator
NASA Technical Reports Server (NTRS)
Cofer, Wesley R., III; Collins, V. G.
1986-01-01
Nebulization reflux concentrator extracts and concentrates trace quantities of water-soluble gases for subsequent chemical analysis. Hydrophobic membrane and nebulizing nozzles form scrubber for removing trace quantities of soluble gases or other contaminants from atmosphere. Although hydrophobic membrane virtually blocks all transport of droplets, it offers little resistance to gas flow; hence, device permits relatively large volumes of gas scrubbed efficiently with very small volumes of liquid. This means analyzable quantities of contaminants concentrate in extracting solutions in much shorter times than with conventional techniques.
Birthday Cake Activity Structured Arrangement for Helping Children Determining Quantities
ERIC Educational Resources Information Center
Mariana, Neni
2010-01-01
Few researches have been concerned about relation between children's spatial thinking and number sense. Narrowing for this small research, we focused on one component of spatial thinking, that is structuring objects, and one component of number senses, that is cardinality by determining quantities. This study focused on a design research that was…
Separation of the Carotenoid Bixin from Annatto Seeds Using Thin-Layer and Column Chromatography
ERIC Educational Resources Information Center
McCullagh, James V.; Ramos, Nicholas
2008-01-01
In this experiment the carotenoid bixin is isolated from annatto ("Bixa orellana") seeds using column chromatography. The experiment has several key advantages over previous pigment separation experiments. First, unlike other experiments significant quantities of the carotenoid (typically 20 to 25 mg) can be isolated from small quantities of plant…
Infants Make Quantity Discriminations for Substances
ERIC Educational Resources Information Center
Hespos, Susan J.; Dora, Begum; Rips, Lance J.; Christie, Stella
2012-01-01
Infants can track small groups of solid objects, and infants can respond when these quantities change. But earlier work is equivocal about whether infants can track continuous substances, such as piles of sand. Experiment 1 ("N" = 88) used a habituation paradigm to show infants can register changes in the size of piles of sand that they…
Swingle, W. W.
1919-01-01
1. Amphibian metamorphosis depends upon the amount of iodine secured by the larvæ; the greater the quantity the more rapid the differentiation. 2. Bromine is physiologically inert when fed even in large quantities to frog larvæ, hence it cannot be substituted for iodine. Bromine feeding has no effect on the thyroid. 3. Iodine is the active constituent of the thyroid gland, in the Anura at any rate, and functions within the body by stimulating intracellular oxidations; it is apparently specific in its action. 4. The basal metabolism of patients suffering from athyreosis, whose metabolism is 40 per cent below normal, is very likely held at this figure and prevented from sinking lower to the death point by the introduction of iodine into the body through food and water. 5. The thyroid gland is an organ the function of which is the extraction from the circulation, storage, and supplying to the organism, under the pressure of its needs, the small quantities of iodine taken into the body. The chief function of this gland then is the utilization of iodine in small quantities. PMID:19871773
Detection of Thermal Erosion Gullies from High-Resolution Images Using Deep Learning
NASA Astrophysics Data System (ADS)
Huang, L.; Liu, L.; Jiang, L.; Zhang, T.; Sun, Y.
2017-12-01
Thermal erosion gullies, one type of thermokarst landforms, develop due to thawing of ice-rich permafrost. Mapping the location and extent of thermal erosion gullies can help understand the spatial distribution of thermokarst landforms and their temporal evolution. Remote sensing images provide an effective way for mapping thermokarst landforms, especially thermokarst lakes. However, thermal erosion gullies are challenging to map from remote sensing images due to their small sizes and significant variations in geometric/radiometric properties. It is feasible to manually identify these features, as a few previous studies have carried out. However manual methods are labor-intensive, therefore, cannot be used for a large study area. In this work, we conduct automatic mapping of thermal erosion gullies from high-resolution images by using Deep Learning. Our study area is located in Eboling Mountain (Qinghai, China). Within a 6 km2 peatland area underlain by ice-rich permafrost, at least 20 thermal erosional gullies are well developed. The image used is a 15-cm-resolution Digital Orthophoto Map (DOM) generated in July 2016. First, we extracted 14 gully patches and ten non-gully patches as training data. And we performed image augmentation. Next, we fine-tuned the pre-trained model of DeepLab, a deep-learning algorithm for semantic image segmentation based on Deep Convolutional Neural Networks. Then, we performed inference on the whole DOM and obtained intermediate results in forms of polygons for all identified gullies. At last, we removed misidentified polygons based on a few pre-set criteria on the size and shape of each polygon. Our final results include 42 polygons. Validated against field measurements using GPS, most of the gullies are detected correctly. There are 20 false detections due to the small number and low quality of training images. We also found three new gullies that missed in the field observations. This study shows that (1) despite a challenging mapping task, DeepLab can detect small, irregular-shaped thermal erosion gullies with high accuracy. (2) Automatic detection is critical for mapping thermal erosion gully since manual mapping or field work may miss some targets even in a relatively small region. (3) The quantity and quality of training data are crucial for detection accuracy.
Acoustical sensing of cardiomyocyte cluster beating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tymchenko, Nina; Kunze, Angelika; Dahlenborg, Kerstin
2013-06-14
Highlights: •An example of the application of QCM-D to live cell studies. •Detection of human pluripotent stem cell-derived cardiomyocyte cluster beating. •Clusters were studied in a thin liquid film and in a large liquid volume. •The QCM-D beating profile provides an individual fingerprint of the hPS-CMCs. -- Abstract: Spontaneously beating human pluripotent stem cell-derived cardiomyocytes clusters (CMCs) represent an excellent in vitro tool for studies of human cardiomyocyte function and for pharmacological cardiac safety assessment. Such testing typically requires highly trained operators, precision plating, or large cell quantities, and there is a demand for real-time, label-free monitoring of small cellmore » quantities, especially rare cells and tissue-like structures. Array formats based on sensing of electrical or optical properties of cells are being developed and in use by the pharmaceutical industry. A potential alternative to these techniques is represented by the quartz crystal microbalance with dissipation monitoring (QCM-D) technique, which is an acoustic surface sensitive technique that measures changes in mass and viscoelastic properties close to the sensor surface (from nm to μm). There is an increasing number of studies where QCM-D has successfully been applied to monitor properties of cells and cellular processes. In the present study, we show that spontaneous beating of CMCs on QCM-D sensors can be clearly detected, both in the frequency and the dissipation signals. Beating rates in the range of 66–168 bpm for CMCs were detected and confirmed by simultaneous light microscopy. The QCM-D beating profile was found to provide individual fingerprints of the hPS-CMCs. The presented results point towards acoustical assays for evaluation cardiotoxicity.« less
Quantifying cannabis: A field study of marijuana quantity estimation.
Prince, Mark A; Conner, Bradley T; Pearson, Matthew R
2018-06-01
The assessment of marijuana use quantity poses unique challenges. These challenges have limited research efforts on quantity assessments. However, quantity estimates are critical to detecting associations between marijuana use and outcomes. We examined accuracy of marijuana users' estimations of quantities of marijuana they prepared to ingest and predictors of both how much was prepared for a single dose and the degree of (in)accuracy of participants' estimates. We recruited a sample of 128 regular-to-heavy marijuana users for a field study wherein they prepared and estimated quantities of marijuana flower in a joint or a bowl as well as marijuana concentrate using a dab tool. The vast majority of participants overestimated the quantity of marijuana that they used in their preparations. We failed to find robust predictors of estimation accuracy. Self-reported quantity estimates are inaccurate, which has implications for studying the link between quantity and marijuana use outcomes. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Wang, Xuping; Quan, Long; Xiong, Guangyu
2013-11-01
Currently, most researches use signals, such as the coil current or voltage of solenoid, to identify parameters; typically, parameter identification method based on variation rate of coil current is applied for position estimation. The problem exists in these researches that the detected signals are prone to interference and difficult to obtain. This paper proposes a new method for detecting the core position by using flux characteristic quantity, which adds a new group of secondary winding to the coil of the ordinary switching electromagnet. On the basis of electromagnetic coupling theory analysis and simulation research of the magnetic field regarding the primary and secondary winding coils, and in accordance with the fact that under PWM control mode varying core position and operating current of windings produce different characteristic of flux increment of the secondary winding. The flux increment of the electromagnet winding can be obtained by conducting time domain integration for the induced voltage signal of the extracted secondary winding, and the core position from the two-dimensional fitting curve of the operating winding current and flux-linkage characteristic quantity of solenoid are calculated. The detecting and testing system of solenoid core position is developed based on the theoretical research. The testing results show that the flux characteristic quantity of switching electromagnet magnetic circuit is able to effectively show the core position and thus to accomplish the non-displacement transducer detection of the said core position of the switching electromagnet. This paper proposes a new method for detecting the core position by using flux characteristic quantity, which provides a new theory and method for switch solenoid to control the proportional valve.
SPECTROPHOTOMETRIC DETERMINATION OF ULTRA-SMALL QUANTITIES OF NICKEL IN INDIUM (in Russian)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peshkova, V.M.; Bochkova, V.M.; Astakhova, E.K.
1961-09-01
alpha -Benzil doxime permits the determination of nickel by measuring optical density in the region of maximum absortption (at 275 m mu ), after the reagent excess is removed by washing the extract with alkali. Conditions were found for the spectrophotometric determination of ultra-small quantities (down to 0.005 gamma ) of nickel with alpha -benzil dioxime in the soultion of its pure salt, in the presence of cobalt and copper. A method was developed for the determination of traces of nickel down to 5 x 10 /sup -7%/ in metallic indium. The reproducibility of method is +25%. (auth)
Rapid isolation of mycoviral double-stranded RNA from Botrytis cinerea and Saccharomyces cerevisiae
2011-01-01
Background In most of the infected fungi, the mycoviruses are latent or cryptic, the infected fungus does not show disease symptoms, and it is phenotypically identical to a non-infected strain of the same species. Because of these properties, the initial stage in the search for fungi infected with mycoviruses is the detection of their viral genome, which in most of the described cases corresponds to double-stranded RNA (dsRNA). So to analyze a large number of fungal isolates it is necessary to have a simple and rapid method to detect dsRNA. Results A rapid method to isolate dsRNA from a virus-infected filamentous fungus, Botrytis cinerea, and from a killer strain of Saccharomyces cerevisiae using commercial minicolumns packed with CF11 cellulose was developed. In addition to being a rapid method, it allows to use small quantities of yeasts or mycelium as starting material, being obtained sufficient dsRNA quantity that can later be analyzed by agarose gel electrophoresis, treated with enzymes for its partial characterization, amplified by RT-PCR and cloned in appropriate vectors for further sequencing. Conclusions The method yields high quality dsRNA, free from DNA and ssRNA. The use of nucleases to degrade the DNA or the ssRNA is not required, and it can be used to isolate dsRNA from any type of fungi or any biological sample that contains dsRNA. PMID:21262001
Quantities for assessing high photon doses to the body: a calculational approach.
Eakins, Jonathan S; Ainsbury, Elizabeth A
2018-06-01
Tissue reactions are the most clinically significant consequences of high-dose exposures to ionising radiation. However, currently there is no universally recognized dose quantity that can be used to assess and report generalised risks to individuals following whole body exposures in the high-dose range. In this work, a number of potential dose quantities are presented and discussed, with mathematical modelling techniques employed to compare them and explore when their differences are most or least manifest. The results are interpreted to propose the average (D GRB ) of the absorbed doses to the stomach, small intestine, red bone marrow, and brain as the optimum quantity for informing assessments of risk. A second, maximally conservative dose quantity (D Max ) is also suggested, which places limits on any under-estimates resulting from the adoption of D GRB . The primary aim of this work is to spark debate, with further work required to refine the final choice of quantity or quantities most appropriate for the full range of different potential exposure scenarios.
Memory for Multiple Cache Locations and Prey Quantities in a Food-Hoarding Songbird
Armstrong, Nicola; Garland, Alexis; Burns, K. C.
2012-01-01
Most animals can discriminate between pairs of numbers that are each less than four without training. However, North Island robins (Petroica longipes), a food-hoarding songbird endemic to New Zealand, can discriminate between quantities of items as high as eight without training. Here we investigate whether robins are capable of other complex quantity discrimination tasks. We test whether their ability to discriminate between small quantities declines with (1) the number of cache sites containing prey rewards and (2) the length of time separating cache creation and retrieval (retention interval). Results showed that subjects generally performed above-chance expectations. They were equally able to discriminate between different combinations of prey quantities that were hidden from view in 2, 3, and 4 cache sites from between 1, 10, and 60 s. Overall results indicate that North Island robins can process complex quantity information involving more than two discrete quantities of items for up to 1 min long retention intervals without training. PMID:23293622
Memory for multiple cache locations and prey quantities in a food-hoarding songbird.
Armstrong, Nicola; Garland, Alexis; Burns, K C
2012-01-01
Most animals can discriminate between pairs of numbers that are each less than four without training. However, North Island robins (Petroica longipes), a food-hoarding songbird endemic to New Zealand, can discriminate between quantities of items as high as eight without training. Here we investigate whether robins are capable of other complex quantity discrimination tasks. We test whether their ability to discriminate between small quantities declines with (1) the number of cache sites containing prey rewards and (2) the length of time separating cache creation and retrieval (retention interval). Results showed that subjects generally performed above-chance expectations. They were equally able to discriminate between different combinations of prey quantities that were hidden from view in 2, 3, and 4 cache sites from between 1, 10, and 60 s. Overall results indicate that North Island robins can process complex quantity information involving more than two discrete quantities of items for up to 1 min long retention intervals without training.
Asbestos release from whole-building demolition of buildings with asbestos-containing material.
Perkins, Robert A; Hargesheimer, John; Fourie, Walter
2007-12-01
The whole-building demolition method, which entails one-or two-story buildings pushed down by heavy equipment, loaded into trucks, and hauled away, is generally the most cost-effective means to remove small buildings. For taller buildings, a crane and wrecking ball may be used initially to reduce the height of the building. Demolitions might release asbestos fibers from friable asbestos-containing material (ACM). Fibers also might be released from nominally nonfriable ACM (Categories I and II nonfriable ACM) if it becomes friable after rough handling throughout the whole-building demolition process. This paper reports on asbestos air monitoring from two demolition projects involving ACM. In one building, Category II nonfriable ACM was present because it could not be removed safely prior to demolition. Both projects had large quantities of gypsum wallboard with ACM joint compound and ACM flooring. One building had large quantities of ACM spray-on ceiling material. During the demolitions personal air monitoring of the workers and area air monitoring downwind and around the sites were conducted. The monitoring found the concentrations of fibers detected by phase contrast microscopy were generally well below the permissible exposure limits (PEL) of workers. Electron microcopy analysis of samples at or near the PEL indicated most of the fibers were not asbestos, and the actual asbestos exposure was often below the detection limit of the procedure. The buildings were kept wet with fire hoses during the demolition and that required large quantities of water, 20,000-60,000 gal/day (75-225 m(3)/day). Earlier studies found little asbestos release from buildings containing only nonfriable ACM demolished by this method. This project found a negligible release of asbestos fibers, despite the presence of nonfriable materials that might become friable, such as ACM joint compound and spray-on ACM ceiling coating.
Recent Developments in MC-ICP-MS for Uranium Isotopic Determination from Small Samples.
NASA Astrophysics Data System (ADS)
Field, P.; Lloyd, N. S.
2016-12-01
V002: Advances in approaches and instruments for isotope studies Session ID#: 12653 Recent Developments in MC-ICP-MS for Uranium Isotopic Determination from small samples.M. Paul Field 1 & Nicholas S. Lloyd. 1 Elemental Scientific Inc., Omaha, Nebraska, USA. field@icpms.com 2 Thermo Fisher Scientific, Hanna-Kunath-Str. 11, 28199 Bremen, Germany. nicholas.lloyd@thermofisher.com Uranium isotope ratio determination for nuclear, nuclear safeguards and for environmental applications can be challenging due to, 1) the large isotopic differences between samples and 2) low abundance of 234U and 236U. For some applications the total uranium quantities can be limited, or it is desirable to run at lower concentrations for radiological protection. Recent developments in inlet systems and detector technologies allow small samples to be analyzed at higher precisions using MC-ICP-MS. Here we evaluate the combination of Elemental Scientific apex omega desolvation system and microFAST-MC dual loop-loading flow-injection system with the Thermo Scientific NEPTUNE Plus MC-ICP-MS. The inlet systems allow for the automated syringe loading and injecting handling of small sample volumes with efficient desolvation to minimize the hydride interference on 236U. The highest ICP ion sampling efficiency is realized using the Thermo Scientific Jet Interface. Thermo Scientific 1013 ohm amplifier technology allows small ion beams to be measured at higher precision, offering the highest signal/noise ratio with a linear and stable response that covers a wide dynamic range (ca. 1 kcps - 30 Mcps). For nanogram quantities of low enriched and depleted uranium standards the 235U was measured with 1013 ohm amplifier technology. The minor isotopes (234U and 236U) were measured by SEM ion counters with RPQ lens filters, which offer the lowest detection limits. For sample amounts ca. 20 ng the minor isotopes can be moved onto 1013 ohm amplifiers and the 235U onto standard 1011 ohm amplifier. To illustrate the application a set of solutions from environmental particles [1] were analyzed, the use of precise three isotope ratio plots allows for source attribution with increased confidence. [1] Lloyd et al. 2009, J. Anal. At. Spectrom., 24(6), 752-758.
Matching algorithm of missile tail flame based on back-propagation neural network
NASA Astrophysics Data System (ADS)
Huang, Da; Huang, Shucai; Tang, Yidong; Zhao, Wei; Cao, Wenhuan
2018-02-01
This work presents a spectral matching algorithm of missile plume detection that based on neural network. The radiation value of the characteristic spectrum of the missile tail flame is taken as the input of the network. The network's structure including the number of nodes and layers is determined according to the number of characteristic spectral bands and missile types. We can get the network weight matrixes and threshold vectors through training the network using training samples, and we can determine the performance of the network through testing the network using the test samples. A small amount of data cause the network has the advantages of simple structure and practicality. Network structure composed of weight matrix and threshold vector can complete task of spectrum matching without large database support. Network can achieve real-time requirements with a small quantity of data. Experiment results show that the algorithm has the ability to match the precise spectrum and strong robustness.
Simon, F.O.; Grimaldi, F.S.
1962-01-01
Rhenium is determined by spectrophotometry of the tellurium sol formed by the reduction of tellurate by stannous chloride under the catalytic influence of rhenium. A detailed investigation of the conditions for high sensitivity and stability at lowest concentration levels of rhenium is presented as well as the behavior of 26 ions. The method is applied to the determination of some tenths of 1 p.p.m. or more of rhenium in a 1-mg. aliquot of mineralized rocks, mixtures of molybdenite and rocks, and molybdenite concentrates. The practical quantity limit of detection is 2 ?? 10-10 gram of rhenium. Samples are decomposed with a mixture of CaO, CaCl2, and MgO. On leaching, most constituents of the sample are precipitated either as calcium salts or hydroxides, except for rhenium and a small amount of molybdenum which pass into the filtrate. Residual molybdenum is removed by extraction with 8-quinolinol in chloroform. Better than 95% recoveries are obtained with two fusions with flux.
Operation and cost of a small dehumidification dry kiln
Richard D. Bergman
2008-01-01
Obtaining small quantities of custom kiln-dried lumber can be an expensive process for an individual woodworker. Building and operating a small kiln capable of drying custom cuts of lumber (such as slabs, bowl blanks) gives woodworkers another option. Our approach was to build and operate a small dehumidification dry kiln. The four charges of lumber ranged from 600 to...
Detecting small holes in packages
Kronberg, J.W.; Cadieux, J.R.
1996-03-19
A package containing a tracer gas, and a method for determining the presence of a hole in the package by sensing the presence of the gas outside the package are disclosed. The preferred tracer gas, especially for food packaging, is sulfur hexafluoride. A quantity of the gas is added to the package and the package is closed. The concentration of the gas in the atmosphere outside the package is measured and compared to a predetermined value of the concentration of the gas in the absence of the package. A measured concentration greater than the predetermined value indicates the presence of a hole in the package. Measuring may be done in a chamber having a lower pressure than that in the package. 3 figs.
Microliter-sized ionization device and method
NASA Technical Reports Server (NTRS)
Simac, Robert M. (Inventor); Wernlund, Roger F. (Inventor); Cohen, Martin J. (Inventor)
1999-01-01
A microliter-sized metastable ionization device with a cavity, a sample gas inlet, a corona gas inlet and a gas outlet. A first electrode has a hollow and disposed in the cavity and is in fluid communication with the sample gas inlet. A second electrode is in fluid communication with the corona gas inlet and is disposed around the first electrode adjacent the hollow end thereof. A gap forming means forms a corona gap between the first and second electrodes. A first power supply is connected to the first electrode and the second power supply is connected to the second electrode for generating a corona discharge across the corona gap. A collector has a hollow end portion disposed in the cavity which is in fluid communications with the gas outlet for the outgassing and detection of ionized gases. The first electrode can be a tubular member aligned concentrically with a cylindrical second electrode. The gap forming means can be in annular disc projecting radially inwardly from the cylindrical second electrode. The collector can have a tubular opening aligned coaxially with the first electrode and has an end face spaced a short distance from an end face of the first electrode forming a small active volume therebetween for the generation and detection of small quantities of trace analytes.
Hoppe, Cindy C; Nguyen, Lida T; Kirsch, Lee E; Wiencek, John M
2008-01-01
Background Glucagon is a peptide hormone with many uses as a therapeutic agent, including the emergency treatment of hypoglycemia. Physical instability of glucagon in solution leads to problems with the manufacture, formulation, and delivery of this pharmaceutical product. Glucagon has been shown to aggregate and form fibrils and gels in vitro. Small oligomeric precursors serve to initiate and nucleate the aggregation process. In this study, these initial aggregates, or seed nuclei, are characterized in bulk solution using light scattering methods and field-flow fractionation. Results High molecular weight aggregates of glucagon were detected in otherwise monomeric solutions using light scattering techniques. These aggregates were detected upon initial mixing of glucagon powder in dilute HCl and NaOH. In the pharmaceutically relevant case of acidic glucagon, the removal of aggregates by filtration significantly slowed the aggregation process. Field-flow fractionation was used to separate aggregates from monomeric glucagon and determine relative mass. The molar mass of the large aggregates was shown to grow appreciably over time as the glucagon solutions gelled. Conclusion The results of this study indicate that initial glucagon solutions are predominantly monomeric, but contain small quantities of large aggregates. These results suggest that the initial aggregates are seed nuclei, or intermediates which catalyze the aggregation process, even at low concentrations. PMID:18613970
The effect of urban green on small-area (healthy) life expectancy.
Jonker, M F; van Lenthe, F J; Donkers, B; Mackenbach, J P; Burdorf, A
2014-10-01
Several epidemiological studies have investigated the effect of the quantity of green space on health outcomes such as self-rated health, morbidity and mortality ratios. These studies have consistently found positive associations between the quantity of green and health. However, the impact of other aspects, such as the perceived quality and average distance to public green, and the effect of urban green on population health are still largely unknown. Linear regression models were used to investigate the impact of three different measures of urban green on small-area life expectancy (LE) and healthy life expectancy (HLE) in The Netherlands. All regressions corrected for average neighbourhood household income, accommodated spatial autocorrelation, and took measurement uncertainty of LE, HLE as well as the quality of urban green into account. Both the quantity and the perceived quality of urban green are modestly related to small-area LE and HLE: an increase of 1 SD in the percentage of urban green space is associated with a 0.1-year higher LE, and, in the case of quality of green, with an approximately 0.3-year higher LE and HLE. The average distance to the nearest public green is unrelated to population health. The quantity and particularly quality of urban green are positively associated with small-area LE and HLE. This concurs with a growing body of evidence that urban green reduces stress, stimulates physical activity, improves the microclimate and reduces ambient air pollution. Accordingly, urban green development deserves a more prominent place in urban regeneration and neighbourhood renewal programmes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Immediate Small Number Perception : Evidence from a New Numerical Carry-Over Procedure
ERIC Educational Resources Information Center
Demeyere, Nele; Humphreys, Glyn W.
2012-01-01
Evidence is presented for the immediate apprehension of exact small quantities. Participants performed a quantification task (are the number of items greater or smaller than?), and carry-over effects were examined between numbers requiring the same response. Carry-over effects between small numbers were strongly affected by repeats of pattern and…
Khan, Rishi L; Gonye, Gregory E; Gao, Guang; Schwaber, James S
2006-01-01
Background Using microarrays by co-hybridizing two samples labeled with different dyes enables differential gene expression measurements and comparisons across slides while controlling for within-slide variability. Typically one dye produces weaker signal intensities than the other often causing signals to be undetectable. In addition, undetectable spots represent a large problem for two-color microarray designs and most arrays contain at least 40% undetectable spots even when labeled with reference samples such as Stratagene's Universal Reference RNAs™. Results We introduce a novel universal reference sample that produces strong signal for all spots on the array, increasing the average fraction of detectable spots to 97%. Maximizing detectable spots on the reference image channel also decreases the variability of microarray data allowing for reliable detection of smaller differential gene expression changes. The reference sample is derived from sequence contained in the parental EST clone vector pT7T3D-Pac and is called vector RNA (vRNA). We show that vRNA can also be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This reference sample can be made inexpensively in large quantities as a renewable resource that is consistent across experiments. Conclusion Results of this study show that vRNA provides a useful universal reference that yields high signal for almost all spots on a microarray, reduces variation and allows for comparisons between experiments and laboratories. Further, it can be used for quality control of microarray printing and PCR product quality, detection of hybridization anomalies, and simplification of spot finding and segmentation tasks. This type of reference allows for detection of small changes in differential expression while reference designs in general allow for large-scale multivariate experimental designs. vRNA in combination with reference designs enable systems biology microarray experiments of small physiologically relevant changes. PMID:16677381
Britton, Jr., Charles L.; Wintenberg, Alan L.
1993-01-01
A radiation detection method and system for continuously correcting the quantization of detected charge during pulse pile-up conditions. Charge pulses from a radiation detector responsive to the energy of detected radiation events are converted to voltage pulses of predetermined shape whose peak amplitudes are proportional to the quantity of charge of each corresponding detected event by means of a charge-sensitive preamplifier. These peak amplitudes are sampled and stored sequentially in accordance with their respective times of occurrence. Based on the stored peak amplitudes and times of occurrence, a correction factor is generated which represents the fraction of a previous pulses influence on a preceding pulse peak amplitude. This correction factor is subtracted from the following pulse amplitude in a summing amplifier whose output then represents the corrected charge quantity measurement.
Practical Stereology Applications for the Pathologist.
Brown, Danielle L
2017-05-01
Qualitative histopathology is the gold standard for routine examination of morphological tissue changes in the regulatory or academic environment. The human eye is exceptional for pattern recognition but often cannot detect small changes in quantity. In cases where detection of subtle quantitative changes is critical, more sensitive methods are required. Two-dimensional histomorphometry can provide additional quantitative information and is quite useful in many cases. However, the provided data may not be referent to the entire tissue and, as such, it makes several assumptions, which are sources of bias. In contrast, stereology is design based rather than assumption based and uses stringent sampling methods to obtain accurate and precise 3-dimensional information using geometrical and statistical principles. Recent advances in technology have made stereology more approachable and practical for the pathologist in both regulatory and academic environments. This review introduces pathologists to the basic principles of stereology and walks the reader through some real-world examples for the application of these principles in the workplace.
Residues of carcinogenic animal drugs in food: difficulties in evaluation of human safety.
Somogyi, A
1979-01-01
The indisputable need to intensify animal production in order to provide an adequate food supply for the world population involves the use of substances that are highly potent pharmacologically and toxicologically. The history of regulatory action with regard to such additives is similar to that for other substances: first, no regulation; next, an over-reaction; and now decisions based on judicious evaluation of scientific facts. One factor that differentiates the chemicals used in animal production from other food additives is that both the parent compounds and their metabolites appear in edible products, posing problems both for the analytical detection and safety evaluation of such residues. It would be unrealistic to propose 'zero' tolerances for these additives, even if they are carcinogenic. The benefits gained from drugs that cure and prevent infections and parasitic diseases in food-producing animals, and the fact that analytical methods can now detect very small quantities make the presence of low levels of these substances in food unobjectionable.
Improved Limits for Higgs-Portal Dark Matter from LHC Searches.
Hoferichter, Martin; Klos, Philipp; Menéndez, Javier; Schwenk, Achim
2017-11-03
Searches for invisible Higgs decays at the Large Hadron Collider constrain dark matter Higgs-portal models, where dark matter interacts with the standard model fields via the Higgs boson. While these searches complement dark matter direct-detection experiments, a comparison of the two limits depends on the coupling of the Higgs boson to the nucleons forming the direct-detection nuclear target, typically parametrized in a single quantity f_{N}. We evaluate f_{N} using recent phenomenological and lattice-QCD calculations, and include for the first time the coupling of the Higgs boson to two nucleons via pion-exchange currents. We observe a partial cancellation for Higgs-portal models that makes the two-nucleon contribution anomalously small. Our results, summarized as f_{N}=0.308(18), show that the uncertainty of the Higgs-nucleon coupling has been vastly overestimated in the past. The improved limits highlight that state-of-the-art nuclear physics input is key to fully exploiting experimental searches.
Development of a leak location system for use on underground electric power transmission cable
NASA Astrophysics Data System (ADS)
Williams, J. A.
1982-10-01
This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000 m long on a feeder that might be 30 km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection and detection scheme was developed for use in areas where the dogs may be unsuitable.
Ruiz-Hidalgo, M J; Eslava, A P; Alvarez, M I; Benito, E P
1999-11-01
A phytoene dehydrogenase-deficient mutant of Mucor circinelloides accumulating only phytoene was transformed with the gene encoding the corresponding enzyme (carB gene) of Phycomyces blakesleeanus. Carotenoids derived from phytoene were detected in the transformants showing that the P. blakesleeanus carB gene complements the M. circinelloides carB mutation. These newly formed carotenoids accumulated in low quantities, indicating that functional complementation was poor. carB mRNA molecules correctly transcribed were detected in the transformants, but they represented a small proportion of the total population of carB-derived mRNAs, mostly constituted by truncated transcripts and by transcripts longer than the transcript that is functional in Phycomyces. These results showed that the P. blakesleeanus carB gene was expressed in M. circinelloides and suggested that the poor complementation observed was owing, at least in part, to the lack of specificity in the recognition of the transcription initiation and termination signals of the P. blakesleeanus carB gene by the M. circinelloides transcriptional machinery.
Precipitation in AISI 316L(N) during creep tests at 550 and 600 °C up to 10 years
NASA Astrophysics Data System (ADS)
Padilha, A. F.; Escriba, D. M.; Materna-Morris, E.; Rieth, M.; Klimenkov, M.
2007-05-01
The precipitation behaviour in the gauge lengths and in the heads of initially solution annealed type 316L(N) austenitic stainless steel specimens tested in creep at 550 and 600 °C for periods of up to 85 000 h has been studied using several metallographic techniques. Three phases were detected: M 23C 6, Laves, and sigma phase. The volume fraction of the precipitated sigma phase was significantly higher than that of carbides and the Laves phase. M 23C 6 carbide precipitation occurred very rapidly and was followed by the sigma and Laves phases formation in the delta ferrite islands. Sigma and Laves phases precipitated at grain boundaries after longer times. Two different mechanisms of sigma phase precipitation have been proposed, one for delta ferrite decomposition and another for grain boundary precipitation. Small quantities of the Laves phase were detected in delta ferrite, at grain boundaries and inside the grains.
Magnetic Nanoparticles for Antibiotics Detection
Cristea, Cecilia; Tertis, Mihaela; Galatus, Ramona
2017-01-01
Widespread use of antibiotics has led to pollution of waterways, potentially creating resistance among freshwater bacterial communities. Microorganisms resistant to commonly prescribed antibiotics (superbug) have dramatically increased over the last decades. The presence of antibiotics in waters, in food and beverages in both their un-metabolized and metabolized forms are of interest for humans. This is due to daily exposure in small quantities, that, when accumulated, could lead to development of drug resistance to antibiotics, or multiply the risk of allergic reaction. Conventional analytical methods used to quantify antibiotics are relatively expensive and generally require long analysis time associated with the difficulties to perform field analyses. In this context, electrochemical and optical based sensing devices are of interest, offering great potentials for a broad range of analytical applications. This review will focus on the application of magnetic nanoparticles in the design of different analytical methods, mainly sensors, used for the detection of antibiotics in different matrices (human fluids, the environmental, food and beverages samples). PMID:28538684
Nagy, Bálint; Bán, Zoltán; Papp, Zoltán
2005-10-01
The quality and the quantity of isolated DNA have an effect on PCR amplifications. The authors studied three DNA isolation protocols (resin binding method using fresh and frozen amniotic fluid samples, and silica adsorption method using fresh samples) on the quantity and on the quality of the isolated DNA. Amniotic fluid samples were obtained from 20 pregnant women. The isolated DNA concentrations were determined by real-time fluorimeter using SYBRGreen I method. Each sample was studied for the presence of 8 STR markers. The authors compared the number of the detected alleles, electrophoretograms and peak areas. There was a significant difference between the concentration of the obtained DNA and in the peak areas between the three isolation protocols. The numbers of detected alleles were different, we observed the most allele drop outs in the resin type DNA isolation protocol from the fresh sample (detected allele numbers 182), followed by resin binding protocol from the frozen samples (detected allele number 243) and by the silica adsorption method (detected allele number 264). The authors demonstrated that the DNA isolation method has an effect on the quantity and quality of the isolated DNA, and on further PCR amplifications.
Research on the effects of urbanization on small stream flow quantity
DOT National Transportation Integrated Search
1978-12-01
This study is a preliminary investigation into the feasibility of using simple techniques to evaluate the effects of urbanization on flood flows in small streams. A number of regression techniques and computer simulation techniques were evaluated, an...
Jin, Ya; Zhang, Jun; Yuan, Qi; Manabe, Takashi; Tan, Wen
2015-08-01
Soluble proteins of human bronchial smooth muscle cells (HBSMC) were separated by nondenaturing micro 2DE and a 30 mm × 40 mm area of the CBB-stained slab gel (1.0 mm thick) was cut into 1.1 mm × 1.1 mm squares, then the proteins in the 972 gel pieces (squares) were applied to quantitative LC-MS/MS. Grid-cutting of the gel was employed to; (i) ensure the total analysis of the proteins in the area, (ii) standardize the conditions of analysis by LC-MS/MS, (iii) reconstruct the protein distribution patterns from the quantity data [1]. Totally 4323 proteins were identified in successfully analyzed 967 squares and the quantity distribution of each was reconstructed as a color density pattern (a native protein map). The quantity of the proteins distributed from 3.6% to 1 × 10(-5) % of the total protein quantity in the grid area. Each protein map was characterized by several features, including the position of quantity peak square, number of detected squares, and degree of concentration (focused or dispersed). About 4% of the proteins were detected in 100 or more squares, suggesting that they might be ubiquitous and interacting with other proteins. In contrast, many proteins showed more concentrated quantity distribution and the quantity peak positions of 565 proteins with a defined degree of concentration were summarized into a quantity peak map. These results for the first time visualized the distribution patterns of cellular proteins on a nondenaturing 2D gel. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Set size and culture influence children's attention to number.
Cantrell, Lisa; Kuwabara, Megumi; Smith, Linda B
2015-03-01
Much research evidences a system in adults and young children for approximately representing quantity. Here we provide evidence that the bias to attend to discrete quantity versus other dimensions may be mediated by set size and culture. Preschool-age English-speaking children in the United States and Japanese-speaking children in Japan were tested in a match-to-sample task where number was pitted against cumulative surface area in both large and small numerical set comparisons. Results showed that children from both cultures were biased to attend to the number of items for small sets. Large set responses also showed a general attention to number when ratio difficulty was easy. However, relative to the responses for small sets, attention to number decreased for both groups; moreover, both U.S. and Japanese children showed a significant bias to attend to total amount for difficult numerical ratio distances, although Japanese children shifted attention to total area at relatively smaller set sizes than U.S. children. These results add to our growing understanding of how quantity is represented and how such representation is influenced by context--both cultural and perceptual. Copyright © 2014 Elsevier Inc. All rights reserved.
A Kinetic Study Using Evaporation of Different Types of Hand-Rub Sanitizers
ERIC Educational Resources Information Center
Pinhas, Allan R.
2010-01-01
Alcohol-based hand-rub sanitizers are the types of products that hospital professionals use very often. These sanitizers can be classified into two major groups: those that contain a large quantity of thickener, and thus are a gel, and those that contain a small quantity of thickener, and thus remain a liquid. In an effort to create a laboratory…
Organic debris in small streams, Prince of Wales Island, Southeast Alaska.
Frederick J. Swanson; Mason D. Bryant; George W. Lienkaemper; James R. Sedell
1984-01-01
Quantities of coarse and fine organic debris in streams flowing through areas clearcut before 1975 are 3 and 6 times greater than quantities in streams sampled in old-growth stands in Tongass National Forest, central Prince of Wales Island, southeast Alaska. The concentration of debris in streams of clearcut Sitka spruce-western hemlock forests in southeast Alaska,...
Proliferation resistance of small modular reactors fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polidoro, F.; Parozzi, F.; Fassnacht, F.
2013-07-01
In this paper the proliferation resistance of different types of Small Modular Reactors (SMRs) has been examined and classified with criteria available in the literature. In the first part of the study, the level of proliferation attractiveness of traditional low-enriched UO{sub 2} and MOX fuels to be used in SMRs based on pressurized water technology has been analyzed. On the basis of numerical simulations both cores show significant proliferation risks. Although the MOX core is less proliferation prone in comparison to the UO{sub 2} core, it still can be highly attractive for diversion or undeclared production of nuclear material. Inmore » the second part of the paper, calculations to assess the proliferation attractiveness of fuel in typical small sodium cooled fast reactor show that proliferation risks from spent fuel cannot be neglected. The core contains a highly attractive plutonium composition during the whole life cycle. Despite some aspects of the design like the sealed core that enables easy detection of unauthorized withdrawal of fissile material and enhances proliferation resistance, in case of open Non-Proliferation Treaty break-out, weapon-grade plutonium in sufficient quantities could be extracted from the reactor core.« less
NASA Astrophysics Data System (ADS)
Wu, Xiao Chu; Qing Wu, Dong; Sammynaiken, R.; Yang, Wei; Wang, Rui; Zhang, W. J.
2008-11-01
Endogenously generated hydrogen sulfide (H2S) has been found to play some important physiological roles in the nervous and cardiovascular systems, such as a neuromodulator and a vasorelaxant. These roles are in contrast to our common perception that H2S is toxic. However, whether H2S plays a positive or negative role is dependent on the H2S concentration levels in mammals. This further puts a high demand on the accurate measurement of H2S in mammals with a further desire to be real time, continuous and in vivo. Existing methods for H2S measurement require a large number of tissue samples with complex procedures, and these methods are extremely invasive. The development of new in vivo and real-time methods for measuring H2S is, however, a great challenge. In the present study, we proposed and examined five potential H2S measurement methods: (1) atomic force microscopy with coating materials, (2) Raman spectroscopy on the H2S solutions, (3) gas chromatography/mass spectroscopy (with the static headspace technique) on the H2S solutions, (4) mass spectroscopy on unfunctionalized carbon nanotubes treated with the H2S solutions and (5) Raman spectroscopy on unfunctionalized carbon nanotubes treated with the H2S solutions. Our study concluded that method (5) is the most promising one for detecting low concentration H2S in small-quantity aqueous solutions in terms of measurement resolution and non-invasiveness, but the method is not very robust.
76 FR 37835 - Petitions for Modification of Application of Existing Mandatory Safety Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... small quantity of steel turnings, or other small magnetic particles, will be embedded in the top of the..., Cementation USA, to apply the 500 feet per minute requirement to the man-riding conveyance as well as the...
Levitt, Steven D.; List, John A.; Neckermann, Susanne; Nelson, David
2016-01-01
We report on a natural field experiment on quantity discounts involving more than 14 million consumers. Implementing price reductions ranging from 9–70% for large purchases, we found remarkably little impact on revenue, either positively or negatively. There was virtually no increase in the quantity of customers making a purchase; all the observed changes occurred for customers who already were buyers. We found evidence that infrequent purchasers are more responsive to discounts than frequent purchasers. There was some evidence of habit formation when prices returned to pre-experiment levels. There also was some evidence that consumers contemplating small purchases are discouraged by the presence of extreme quantity discounts for large purchases. PMID:27382146
Kurath, Gael; Jolley, C J.; Thompson, Tarin M.; Thompson, D.; Whitesel, A.T.; Gutenberger, S.; Winton, James R.
2013-01-01
Pacific Lampreys Entosphenus tridentatus have experienced severe population declines in recent years and efforts to develop captive rearing programs are under consideration. However, there is limited knowledge of their life history, ecology, and potential to harbor or transmit pathogens that may cause infectious disease. As a measure of the possible risks associated with introducing wild lampreys into existing fish culture facilities, larval lampreys (ammocoetes) were tested for susceptibility to infection and mortality caused by experimental exposures to the fish rhabdovirus pathogens: infectious hematopoietic necrosis virus (IHNV) and viral haemorrhagic septicaemia virus (VHSV). Two IHNV isolates, representing the U and M genogroups, and one VHSV isolate from the IVa genotype were each delivered to groups of ammocoetes by immersion at moderate and high viral doses, and by intraperitoneal injection. Ammocoetes were then held in triplicate tanks with no substrate or sediment. During 41 d of observation postchallenge there was low or no mortality in all groups, and no virus was detected in the small number of fish that died. Ammocoetes sampled for incidence of infection at 6 and 12 d after immersion challenges also had no detectable virus, and no virus was detected in surviving fish from any group. A small number of ammocoetes sampled 6 d after the injection challenge had detectable virus, but at levels below the original quantity of virus injected. Overall there was no evidence of infection, replication, or persistence of any of the viruses in any of the treatment groups. Our results suggest that Pacific Lampreys are highly unlikely to serve as hosts that maintain or transmit these viruses.
ERIC Educational Resources Information Center
Papenberg, Martin; Musch, Jochen
2017-01-01
In multiple-choice tests, the quality of distractors may be more important than their number. We therefore examined the joint influence of distractor quality and quantity on test functioning by providing a sample of 5,793 participants with five parallel test sets consisting of items that differed in the number and quality of distractors.…
Enzyme catalysis with small ionic liquid quantities.
Fischer, Fabian; Mutschler, Julien; Zufferey, Daniel
2011-04-01
Enzyme catalysis with minimal ionic liquid quantities improves reaction rates, stereoselectivity and enables solvent-free processing. In particular the widely used lipases combine well with many ionic liquids. Demonstrated applications are racemate separation, esterification and glycerolysis. Minimal solvent processing is also an alternative to sluggish solvent-free catalysis. The method allows simplified down-stream processing, as only traces of ionic liquids have to be removed.
iMAST Quarterly, Number 3, 2000
2000-01-01
components which depend on evaporating unit capabilities. There are three components (EB-gun, water cooled copper crucible and vacuum chamber) in the EB-PVD...Ion Implantation and Ion Plating electromagnetic deflected through 180 or 2700. Similarly, evaporant material is placed in a water-cooled copper ... crucible , which could be either pocket type for small quantity evaporation application or continuous ingot feeding through the crucible for larger quantity
NASA Astrophysics Data System (ADS)
Boi, Filippo S.; Medranda, Daniel; Ivaturi, Sameera; Wang, Jiayu; Guo, Jian; Lan, Mu; Wen, Jiqiu; Wang, Shanling; He, Yi; Mountjoy, Gavin; Willis, Maureen A. C.; Xiang, Gang
2017-06-01
We report the observation of an unusual self-peeling effect which allows the synthesis of free standing vertically aligned carbon nanotube films filled with large quantities of Fe3C and small quantities of γ-Fe crystals. We demonstrate that this effect depends on the interplay of three main factors: (1) the physical interactions between the chosen substrate surface and grown carbon nanotubes (CNTs), which is fixed by the composition of the used substrate (111 SiO2/Si or quartz), (2) the CNT-CNT Van der Waals interactions, and (3) the differential thermal contraction between the grown CNT film and the used substrate, which is fixed by the cooling rate differences between the grown film and the used quartz or Si/SiO2 substrates. The width and stability of these films are then further increased to cm-scale by addition of small quantities of toluene to the ferrocene precursor.
Structure of the Small Amplitude Motion on Transversely Sheared Mean Flows
NASA Technical Reports Server (NTRS)
Goldstein, Marvin E.; Afsar, Mohamed Z.; Leib, Stewart J.
2013-01-01
This paper considers the small amplitude unsteady motion of an inviscid non-heat conducting compressible fluid on a transversely sheared mean flow. It extends a previous result given in Goldstein (1978(b) and 1979(a)) which shows that the hydrodynamic component of the motion is determined by two arbitrary convected quantities in the absence of solid surfaces or other external sources. The result is important because it can be used to specify appropriate boundary conditions for unsteady surface interaction problems on transversely sheared mean flows in the same way that the vortical component of the Kovasznay (1953) decomposition is used to specify these conditions for surface interaction problems on uniform mean flows. But unlike the Kovasznay (1953) case the arbitrary convected quantities no longer bear a simple relation to the physical variables. One purpose of this paper is to derive a formula that relates these quantities to the (physically measurable) vorticity and pressure fluctuations in the flow.
NASA Astrophysics Data System (ADS)
Hwang, Kyo Seon; Jeon, Hye Kyung; Lee, Sang-Myung; Kim, Sang Kyung; Kim, Tae Song
2009-05-01
In this study, we describe the application feasibility of a dynamic microcantilever with regard to the detection of a specific protein in human serum or real blood using an end-point analysis. The mechanical response (i.e., resonant frequency) of a functionalized dynamic microcantilever was shown to be altered by molecular interactions, which allowed for the detection of biomolecules present in small quantities without any additional signal enhancements, such as labeling. For the application of the microcantilever sensors to bioassays of serum samples, the mechanical response from the nonspecific adsorption of abundant proteins must be reduced, because it significantly influences the output signal deviation of the microcantilever sensor. We implemented a label-free prostate specific antigen (PSA) detection protocol in standard serum via our established process, which was designed to minimize nonspecific protein adsorption. PSA is a tumor marker for prostate cancer, with a threshold concentration of 2-4 ng/ml (7.2-14.4 pM) for the distinction between patients and normal individuals. The dynamic range of our dynamic microcantilever-based PSA assay on the background of standard serum ranged between 0.1 and 100 ng/ml (3.6 and 3600 pM). It was suggested that the dynamic microcantilever might allow for the sensitive label-free detection of disease markers in an actual human sample.
Quantitative real-time in vivo detection of magnetic nanoparticles by their nonlinear magnetization
NASA Astrophysics Data System (ADS)
Nikitin, M. P.; Torno, M.; Chen, H.; Rosengart, A.; Nikitin, P. I.
2008-04-01
A novel method of highly sensitive quantitative detection of magnetic nanoparticles (MP) in biological tissues and blood system has been realized and tested in real time in vivo experiments. The detection method is based on nonlinear magnetic properties of MP and the related device can record a very small relative variation of nonlinear magnetic susceptibility up to 10-8 at room temperature, providing sensitivity of several nanograms of MP in 0.1ml volume. Real-time quantitative in vivo measurements of dynamics of MP concentration in blood flow have been performed. A catheter that carried the blood flow of a rat passed through the measuring device. After an MP injection, the quantity of MP in the circulating blood was continuously recorded. The method has also been used to evaluate the MP distribution between rat's organs. Its sensitivity was compared with detection of the radioactive MP based on isotope of Fe59. The comparison of magnetic and radioactive signals in the rat's blood and organ samples demonstrated similar sensitivity for both methods. However, the proposed magnetic method is much more convenient as it is safe, less expensive, and provides real-time measurements in vivo. Moreover, the sensitivity of the method can be further improved by optimization of the device geometry.
NASA Technical Reports Server (NTRS)
Opila, Elizabeth J.; Fox, Dennis S.; Jacobson, Nathan S.
1997-01-01
A high-pressure sampling mass spectrometer was used to detect the volatile species formed from SiO2 at temperatures between 1200C and 1400C in a flowing water vapor/oxygen gas mixture at 1 bar total pressure. The primary vapor species identified was Si(OH)4. The fragment ion Si(OH)3+,' was observed in quantities 3 to 5 times larger than the parent ion Si(OH)4+. The Si(OH)3+ intensity was found to have a small temperature dependence and to increase with the water vapor partial pressure as expected. In addition, SiO(OH)+ believed to be a fragment of SiO(OH)2, was observed. These mass spectral results were compared to the behavior of silicon halides.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braun, G B; Lee, S J; Laurence, T
2008-07-21
Over the past decade the emphasis on single-molecule sensitivity of surface-enhanced Raman spectroscopy (SERS) has brought to prominence the special role played by so-called SERS 'hot spots', oftentimes nanometer-scale junctions between nanostructures. In this report, optimally SERS enhancing silver clusters were synthesized using bifunctional linkers and polymer and/or protein encapsulation. The synthesis, which results in stable clusters even when stored for months or dried and re-dissolved, is scalable to large quantities. Using a sacrificial linker approach we also employ a permeable polymer/protein shell for general small molecule sensing. Finally, we utilize these nanomaterials by tagging specific epitopes on cancer cellsmore » and show that SERS signals from single clusters can be measured routinely.« less
Enzyme-Linked Immunosorbent Assay (ELISA).
Konstantinou, George N
2017-01-01
Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.
Detection of urinary Vi antigen as a diagnostic test for typhoid fever.
Taylor, D N; Harris, J R; Barrett, T J; Hargrett, N T; Prentzel, I; Valdivieso, C; Palomino, C; Levine, M M; Blake, P A
1983-01-01
Since Vi antigen is limited primarily to Salmonella typhi, it has been thought that detection of the antigen may be a useful method for diagnosing acute typhoid fever. The slide coagglutination method and enzyme-linked immunosorbent assay have recently been suggested as ways to detect small quantities of Vi antigen in urine. In Santiago, Chile, we compared the results of these two methods in patients with acute typhoid fever, paratyphoid fever, and other febrile illnesses and in afebrile control subjects. Using a cut-off value that maximally separated typhoid patients from controls, the enzyme-linked immunosorbent assay was positive in 62.4% of 141 patients with culture-proven typhoid infections and in 13.2% of 159 afebrile control subjects. The enzyme-linked immunosorbent assay was false positive in 64.7% of 34 culture-proven paratyphoid A or B patients and 47.1% of 21 patients with other nontyphoidal febrile illnesses. The coagglutination test was positive in 34% of typhoid patients, 14% of afebrile control subjects, and 46% of febrile control subjects. We conclude that these tests when performed with the Vi antibodies employed in this study are of little value for the diagnosis of typhoid fever in this setting. PMID:6630465
Seafood prices reveal impacts of a major ecological disturbance
Smith, Martin D.; Oglend, Atle; Kirkpatrick, A. Justin; Asche, Frank; Bennear, Lori S.; Craig, J. Kevin; Nance, James M.
2017-01-01
Coastal hypoxia (dissolved oxygen ≤ 2 mg/L) is a growing problem worldwide that threatens marine ecosystem services, but little is known about economic effects on fisheries. Here, we provide evidence that hypoxia causes economic impacts on a major fishery. Ecological studies of hypoxia and marine fauna suggest multiple mechanisms through which hypoxia can skew a population’s size distribution toward smaller individuals. These mechanisms produce sharp predictions about changes in seafood markets. Hypoxia is hypothesized to decrease the quantity of large shrimp relative to small shrimp and increase the price of large shrimp relative to small shrimp. We test these hypotheses using time series of size-based prices. Naive quantity-based models using treatment/control comparisons in hypoxic and nonhypoxic areas produce null results, but we find strong evidence of the hypothesized effects in the relative prices: Hypoxia increases the relative price of large shrimp compared with small shrimp. The effects of fuel prices provide supporting evidence. Empirical models of fishing effort and bioeconomic simulations explain why quantifying effects of hypoxia on fisheries using quantity data has been inconclusive. Specifically, spatial-dynamic feedbacks across the natural system (the fish stock) and human system (the mobile fishing fleet) confound “treated” and “control” areas. Consequently, analyses of price data, which rely on a market counterfactual, are able to reveal effects of the ecological disturbance that are obscured in quantity data. Our results are an important step toward quantifying the economic value of reduced upstream nutrient loading in the Mississippi Basin and are broadly applicable to other coupled human-natural systems. PMID:28137850
Seafood prices reveal impacts of a major ecological disturbance.
Smith, Martin D; Oglend, Atle; Kirkpatrick, A Justin; Asche, Frank; Bennear, Lori S; Craig, J Kevin; Nance, James M
2017-02-14
Coastal hypoxia (dissolved oxygen ≤ 2 mg/L) is a growing problem worldwide that threatens marine ecosystem services, but little is known about economic effects on fisheries. Here, we provide evidence that hypoxia causes economic impacts on a major fishery. Ecological studies of hypoxia and marine fauna suggest multiple mechanisms through which hypoxia can skew a population's size distribution toward smaller individuals. These mechanisms produce sharp predictions about changes in seafood markets. Hypoxia is hypothesized to decrease the quantity of large shrimp relative to small shrimp and increase the price of large shrimp relative to small shrimp. We test these hypotheses using time series of size-based prices. Naive quantity-based models using treatment/control comparisons in hypoxic and nonhypoxic areas produce null results, but we find strong evidence of the hypothesized effects in the relative prices: Hypoxia increases the relative price of large shrimp compared with small shrimp. The effects of fuel prices provide supporting evidence. Empirical models of fishing effort and bioeconomic simulations explain why quantifying effects of hypoxia on fisheries using quantity data has been inconclusive. Specifically, spatial-dynamic feedbacks across the natural system (the fish stock) and human system (the mobile fishing fleet) confound "treated" and "control" areas. Consequently, analyses of price data, which rely on a market counterfactual, are able to reveal effects of the ecological disturbance that are obscured in quantity data. Our results are an important step toward quantifying the economic value of reduced upstream nutrient loading in the Mississippi Basin and are broadly applicable to other coupled human-natural systems.
NASA Astrophysics Data System (ADS)
Zhang, Tong; Sun, Hao; Wang, Fengdi; Zhang, Wanqiao; Ma, Junmei; Tang, Shuwei; Gong, Hongwei; Zhang, Jingping
2018-01-01
Phosgene, one of the common chemicals in many industry areas, is extremely harmful to human and the environment. Thus, it is necessary to design the advanced materials to detect or remove phosgene effectively. In fact, detection or adsorption of some small gas molecules are not the most difficult to actualize. Whereas, one of the primary challenges is the gas molecules desorption from the adsorbent for the purpose of recycling of substrate materials since the small gas molecules interacts strongly with the substrates. In this work, the interaction between the phosgene molecule and pristine or Mn-doped graphene sheets with different electric field and charge state are investigated by using first-principles simulations. Our results show that the adsorption energy of phosgene on Mn-doped graphene is dramatically weakened by applying an external negative electric field but is obviously enhanced by introducing a positive electric field. These processes can be easily controlled by transform the direction of the electric field. Thus, introducing an external electric field or charge in the system may be an excellent method to control the phosgene molecule adsorption and desorption on Mn-doped graphene sheet. All energy needed is just a small quantity of electricity, which satisfies well the requirement of green chemistry and sustainable development. The mechanism and reason of reversible adsorption/desorption is also revealed in terms of energy, charge distribution and orbital analysis. Such spontaneous adsorption or desorption makes Mn-doped graphene to be used as an excellent reusable scavenger of phosgene.
Technique for ultrasonic cleaning with volatile solvents eliminates need for hoods or condensers
NASA Technical Reports Server (NTRS)
Pipersky, E.
1969-01-01
Technique ultrasonically cleans small quantities of small mechanical parts in organic solvents without the need for vapor removal equipment. Parts are placed in a thin plastic bag with the solvent and then suspended in a cleaning tank containing the water-detergent solution.
Miller, M.
2002-01-01
In 2001, one mine in Utah produced a small quantity of fluorspar. The majority of fluorspar consumed in the United States continued to come from imports or material purchased from the US National Defense Stockpile (NDS). In addition, a small amount of synthetic fluorspar (CaF2) was produced from industrial waste streams.
Time Processing in Dyscalculia
Cappelletti, Marinella; Freeman, Elliot D.; Butterworth, Brian L.
2011-01-01
To test whether atypical number development may affect other types of quantity processing, we investigated temporal discrimination in adults with developmental dyscalculia (DD). This also allowed us to test whether number and time may be sub-served by a common quantity system or decision mechanisms: if they do, both should be impaired in dyscalculia, but if number and time are distinct they should dissociate. Participants judged which of two successively presented horizontal lines was longer in duration, the first line being preceded by either a small or a large number prime (“1” or “9”) or by a neutral symbol (“#”), or in a third task participants decided which of two Arabic numbers (either “1,” “5,” “9”) lasted longer. Results showed that (i) DD’s temporal discriminability was normal as long as numbers were not part of the experimental design, even as task-irrelevant stimuli; however (ii) task-irrelevant numbers dramatically disrupted DD’s temporal discriminability the more their salience increased, though the actual magnitude of the numbers had no effect; in contrast (iii) controls’ time perception was robust to the presence of numbers but modulated by numerical quantity: therefore small number primes or numerical stimuli seemed to make durations appear shorter than veridical, but longer for larger numerical prime or numerical stimuli. This study is the first to show spared temporal discrimination – a dimension of continuous quantity – in a population with a congenital number impairment. Our data reinforce the idea of a partially shared quantity system across numerical and temporal dimensions, which supports both dissociations and interactions among dimensions; however, they suggest that impaired number in DD is unlikely to originate from systems initially dedicated to continuous quantity processing like time. PMID:22194731
Time processing in dyscalculia.
Cappelletti, Marinella; Freeman, Elliot D; Butterworth, Brian L
2011-01-01
To test whether atypical number development may affect other types of quantity processing, we investigated temporal discrimination in adults with developmental dyscalculia (DD). This also allowed us to test whether number and time may be sub-served by a common quantity system or decision mechanisms: if they do, both should be impaired in dyscalculia, but if number and time are distinct they should dissociate. Participants judged which of two successively presented horizontal lines was longer in duration, the first line being preceded by either a small or a large number prime ("1" or "9") or by a neutral symbol ("#"), or in a third task participants decided which of two Arabic numbers (either "1," "5," "9") lasted longer. Results showed that (i) DD's temporal discriminability was normal as long as numbers were not part of the experimental design, even as task-irrelevant stimuli; however (ii) task-irrelevant numbers dramatically disrupted DD's temporal discriminability the more their salience increased, though the actual magnitude of the numbers had no effect; in contrast (iii) controls' time perception was robust to the presence of numbers but modulated by numerical quantity: therefore small number primes or numerical stimuli seemed to make durations appear shorter than veridical, but longer for larger numerical prime or numerical stimuli. This study is the first to show spared temporal discrimination - a dimension of continuous quantity - in a population with a congenital number impairment. Our data reinforce the idea of a partially shared quantity system across numerical and temporal dimensions, which supports both dissociations and interactions among dimensions; however, they suggest that impaired number in DD is unlikely to originate from systems initially dedicated to continuous quantity processing like time.
Quantitative detection of type A staphylococcal enterotoxin by Laurell electroimmunodiffusion.
Gasper, E; Heimsch, R C; Anderson, A W
1973-03-01
The detection of staphylococcal enterotoxin A by the quantitative technique of electroimmunodiffusion is described. High dilutions of type-specific rabbit antiserum were used in 1% agarose gels, 1 mm thick, and prepared in 0.05-mug barbital buffer, pH 8.6. Volumes of 10 muliters containing 1.5 to 10 ng of toxin were electrophoresed out of 4-mm diameter wells at 5 mA/cm width of gel. The precipitin cones formed were made visible by first immersing the agarose gels in 0.2 M NaCl and then overlaying the surface with the purified globulin fraction of sheep serum against rabbit globulin, followed by soaking of the gels in 1% aqueous cadmium acetate and staining with 0.1% thiazine red in 1% glacial acetic acid. Fully extended cones, 4 to 23 mm in length depending on toxin concentration and antiserum dilution, were developed in 2 to 5 h of electrophoresis, and visualization was achieved within 2 to 3 h. Because the method is qualitative, quantitative, simple, rapid, and sensitive, it offers a practical tool for the detection of small amounts of bacterial toxins in contaminated foods. The method should also qualify as a sensitive detection device in biochemical procedures which attempt to trace, detect, and identify biological substances in nanogram quantities, provided these substances are antigenic and capable of forming a precipitate with their specific antibodies.
Panteleeva, Sofia; Reznikova, Zhanna; Vygonyailova, Olga
2013-01-01
We simulated the situation of risky hunting in the striped field mouse Apodemus agrarius in order to examine whether these animals are able to make a choice between small and large quantities of live prey (ants). In the first (preliminary) experiment we investigated to what extent mice were interested in ants as a live prey and how their hunting activity depended on the quantity of these edible but rather aggressive insects. We placed mice one by one into arenas together with ant groups of different quantities, from 10 to 60. Surprisingly, animals, both wild-caught and laboratory-reared, displayed rather skilled predatory attacks: mice killed and ate from 0.37 ± 003 to 4 ± 0.5 ants per minute. However, there was a threshold number of ants in the arenas when rodents expressed signs of discomfort and started to panic, likely because ants bit them. This threshold corresponds to the dynamic density (about 400 individuals per m2 per min) in the vicinity of anthills and ants' routes in natural environment. In the second experiment mice had to choose between different quantities of ants placed in two transparent tunnels. Ants here served both as food items and as a source of danger. As far as we know, this is the first experimental paradigm based on evaluation of quantity judgments in the context of risk/reward decision making where the animals face a trade-off between the hedonistic value of the prey and the danger it presents. We found that when mice have to choose between 5 vs. 15, 5 vs. 30, and 10 vs. 30 ants, they always tend to prefer the smaller quantity, thus displaying the capacity for distinguishing more from less in order to ensure comfortable hunting. The results of this study are ecologically relevant as they reflect situations and challenges faced by free-living small rodents. PMID:23407476
DOE Office of Scientific and Technical Information (OSTI.GOV)
Armour, M.A.; Nelson, C.; Sather, P. Briker, Y.
Users of pesticides may have waste or surplus quantities or spills for disposal. One alternative is to deactivate the pesticide at the handling site by using a straightforward chemical reaction. This option can be practical for those who use relatively small quantities of a large variety of pesticides, for example, greenhouse workers, small farmers, and agricultural researchers. This paper describes practical on-site methods for the disposal of spills or small waste quantities of five commonly used pesticides, Diazinon, Chlorpyrifos, Iprodione, 2,4-D, and Captan. These have been tested in the laboratory for the rate of disappearance of the pesticide, the degreemore » of conversion to nontoxic products, the nature and identity of the products, the practicality of the method, and the ease of reproducibility. Methods selected were shown to be safe for the operator, reliable, and reproducible. Greater than 99% of the starting material had to be reacted under reasonable conditions and length of time. Detailed descriptions of the reactions are presented, so that they can be performed with reproducible results. Protective clothing worn during the handling and application of pesticides may become contaminated. Simple laundering does not always remove all of the pesticide residues. Thus, chronic dermal exposure may result from the pesticide-contaminated clothing. Appropriate methods of laundering using specific pretreatments have been determined. 7 refs.« less
27 CFR 40.183 - Record of tobacco products.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES... quantities of all tobacco products, by kind (small cigars-large cigars; small cigarettes-large cigarettes... inventory; (e) Removed subject to tax (itemize large cigars by sale price in accordance with § 40.22, except...
An Accounting System for Solid Waste Management in Small Communities.
ERIC Educational Resources Information Center
Zausner, Eric R.
This pamphlet provides a guide to the type and quantity of information to be collected for effective solid waste management in small communities. It is directed at municipal or private personnel involved in the operation and ownership of management facilities. Sample activity reports are included for reference. (CS)
Code of Federal Regulations, 2010 CFR
2010-10-01
... preparation and extended storage of food. This does not include small alcohol or propane stoves with limited cooking capability, or ice chests or similar devices that are intended for keeping small quantities of food for short durations. High seas means the waters beyond a line three nautical miles seaward of the...
Miller, M.
2003-01-01
The United States had a small quantity of fluorspar production from one mine in Utah during 2002. Most of the fluorspar consumed in the United States continued to come from imports or material purchased from the National Defense Stockpile (NDS). In addition, a small amount of synthetic fluorspar (CaF2) was produced from industrial waste streams.
27 CFR 40.183 - Record of tobacco products.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES... quantities of all tobacco products, by kind (small cigars-large cigars; small cigarettes-large cigarettes... inventory; (e) Removed subject to tax (itemize large cigars by sale price in accordance with § 40.22, except...
27 CFR 40.183 - Record of tobacco products.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., DEPARTMENT OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES... quantities of all tobacco products, by kind (small cigars-large cigars; small cigarettes-large cigarettes... inventory; (e) Removed subject to tax (itemize large cigars by sale price in accordance with § 40.22, except...
Large-scale preparation of plasmid DNA.
Heilig, J S; Elbing, K L; Brent, R
2001-05-01
Although the need for large quantities of plasmid DNA has diminished as techniques for manipulating small quantities of DNA have improved, occasionally large amounts of high-quality plasmid DNA are desired. This unit describes the preparation of milligram quantities of highly purified plasmid DNA. The first part of the unit describes three methods for preparing crude lysates enriched in plasmid DNA from bacterial cells grown in liquid culture: alkaline lysis, boiling, and Triton lysis. The second part describes four methods for purifying plasmid DNA in such lysates away from contaminating RNA and protein: CsCl/ethidium bromide density gradient centrifugation, polyethylene glycol (PEG) precipitation, anion-exchange chromatography, and size-exclusion chromatography.
Method for providing a low density high strength polyurethane foam
Whinnery, Jr., Leroy L.; Goods, Steven H.; Skala, Dawn M.; Henderson, Craig C.; Keifer, Patrick N.
2013-06-18
Disclosed is a method for making a polyurethane closed-cell foam material exhibiting a bulk density below 4 lbs/ft.sup.3 and high strength. The present embodiment uses the reaction product of a modified MDI and a sucrose/glycerine based polyether polyol resin wherein a small measured quantity of the polyol resin is "pre-reacted" with a larger quantity of the isocyanate in a defined ratio such that when the necessary remaining quantity of the polyol resin is added to the "pre-reacted" resin together with a tertiary amine catalyst and water as a blowing agent, the polymerization proceeds slowly enough to provide a stable foam body.
Comparison of metal release from various metallic biomaterials in vitro.
Okazaki, Yoshimitsu; Gotoh, Emiko
2005-01-01
To investigate the metal release of each base and alloying elements in vitro, SUS316L stainless steel, Co-Cr-Mo casting alloy, commercially pure Ti grade 2, and Ti-6Al-4V, V-free Ti-6Al-7Nb and Ti-15Zr-4Nb-4Ta alloys were immersed in various solutions, namely, alpha-medium, PBS(-), calf serum, 0.9% NaCl, artificial saliva, 1.2 mass% L-cysteine, 1 mass% lactic acid and 0.01 mass% HCl for 7d. The difference in the quantity of Co released from the Co-Cr-Mo casting alloy was relatively small in all the solutions. The quantities of Ti released into alpha-medium, PBS(-), calf serum, 0.9% NaCl and artificial saliva were much lower than those released into 1.2% L-cysteine, 1% lactic acid and 0.01% HCl. The quantity of Fe released from SUS316L stainless steel decreased linearly with increasing pH. On the other hand, the quantity of Ti released from Ti materials increased with decreasing pH, and it markedly attenuated at pHs of approximately 4 and higher. The quantity of Ni released from stainless steel gradually decreased with increasing pH. The quantities of Al released from the Ti-6Al-4V and Ti-6Al-7Nb alloys gradually decreased with increasing pH. A small V release was observed in calf serum, PBS(-), artificial saliva, 1% lactic acid, 1.2% l-cysteine and 0.01% HCl. The quantity of Ti released from the Ti-15Zr-4Nb-4Ta alloy was smaller than those released from the Ti-6Al-4V and Ti-6Al-7Nb alloys in all the solutions. In particular, it was approximately 30% or smaller in 1% lactic acid, 1.2% L-cysteine and 0.01% HCl. The quantity of (Zr + Nb + Ta) released was also considerably lower than that of (Al + Nb) or (Al + V) released. Therefore, the Ti-15Zr-4Nb-4Ta alloy with its low metal release in vitro is considered advantageous for long-term implants. Copyright 2004 Elsevier Ltd.
Chen, Kuan-Ling; Jiang, Shiuh-Jen; Chen, Yen-Ling
2017-03-01
International limits have been established for metal impurities in cosmetics to prevent overexposure to heavy metal ions. Sweeping via dynamic chelation was developed using capillary electrophoresis to analyze lead (Pb), cadmium (Cd) and mercury (Hg) impurities in cosmetics. The sweeping via dynamic chelation mechanism involves a large volume of metal ions being swept by a small quantity of chelating agents that were electrokinetically injected into the capillary to chelate metal ions and increase the detection sensitivity. The optimized conditions were as follows: Firstly, the capillary was rinsed by a 0.6 mM TTAB solution to reverse the EOF. The sample solution, which was diluted using 25 mM ammonium acetate (pH 6.0), was injected into the capillary using a pressure of 3.5 psi for 99.9 s. Then, EDTA was injected at -25 kV for 1 min from the EDTA buffer (25 mM ammonium acetate containing 0.6 mM TTAB and 5 mM EDTA), and the metal ions were swept and stacked simultaneously. Finally, the separation was performed at -20 kV using a separation buffer (100 mM ammonium acetate (pH 6.0)). A small quantity of chelating agents introduced into the capillary could yield 33-, 50- and 100-fold detection improvements for Pb, Cd and Hg, respectively, more sensitive than conventional capillary zone electrophoresis. Correlation coefficients greater than 0.998 indicated that this method exhibited good linearity. The relative standard deviation and relative error were less than 8.7%, indicating high precision and accuracy. The recovery value of the homemade lotion, which was employed to simulate the real sample matrix, was 93-104%, which indicated that the sample matrix does not affect the quantitative results. Finally, commercial cosmetics were employed to demonstrate the feasibility of the method to determine Pb, Cd and Hg without complicated sample pretreatment. Graphical Abstract The procedure of analyzing metal ions in cosmetics by sweeping via dynamic chelation.
Hamatani, Kiyohiro; Eguchi, Hidetaka; Mukai, Mayumi; Koyama, Kazuaki; Taga, Masataka; Ito, Reiko; Hayashi, Yuzo; Nakachi, Kei
2010-01-01
Since many thyroid cancer tissue samples from atomic bomb (A-bomb) survivors have been preserved for several decades as unbuffered formalin-fixed, paraffin-embedded specimens, molecular oncological analysis of such archival specimens is indispensable for clarifying the mechanisms of thyroid carcinogenesis in A-bomb survivors. Although RET gene rearrangements are the most important targets, it is a difficult task to examine all of the 13 known types of RET gene rearrangements with the use of the limited quantity of RNA that has been extracted from invaluable paraffin-embedded tissue specimens of A-bomb survivors. In this study, we established an improved 5' rapid amplification of cDNA ends (RACE) method using a small amount of RNA extracted from archival thyroid cancer tissue specimens. Three archival thyroid cancer tissue specimens from three different patients were used as in-house controls to determine the conditions for an improved switching mechanism at 5' end of RNA transcript (SMART) RACE method; one tissue specimen with RET/PTC1 rearrangement and one with RET/PTC3 rearrangement were used as positive samples. One other specimen, used as a negative sample, revealed no detectable expression of the RET gene tyrosine kinase domain. We established a 5' RACE method using an amount of RNA as small as 10 ng extracted from long-term preserved, unbuffered formalin-fixed, paraffin-embedded thyroid cancer tissue by application of SMART technology. This improved SMART RACE method not only identified common RET gene rearrangements, but also isolated a clone containing a 93-bp insert of rare RTE/PTC8 in RNA extracted from formalin-fixed, paraffin-embedded thyroid cancer specimens from one A-bomb survivor who had been exposed to a high radiation dose. In addition, in the papillary thyroid cancer of another high-dose A-bomb survivor, this method detected one novel type of RET gene rearrangement whose partner gene is acyl coenzyme A binding domain 5, located on chromosome 10p. We conclude that our improved SMART RACE method is expected to prove useful in molecular analyses using archival formalin-fixed, paraffin-embedded tissue samples of limited quantity.
NASA Astrophysics Data System (ADS)
Antolín-Urbaneja, J. C.; Eguizabal, I.; Briz, N.; Dominguez, A.; Estensoro, P.; Secchi, A.; Varriale, A.; Di Giovanni, S.; D'Auria, S.
2013-05-01
Several techniques for detecting chemical drug precursors have been developed in the last decade. Most of them are able to identify molecules at very low concentration under lab conditions. Other commercial devices are able to detect a fixed number and type of target substances based on a single detection technique providing an absence of flexibility with respect to target compounds. The construction of compact and easy to use detection systems providing screening for a large number of compounds being able to discriminate them with low false alarm rate and high probability of detection is still an open concern. Under CUSTOM project, funded by the European Commission within the FP7, a stand-alone portable sensing device based on multiple techniques is being developed. One of these techniques is based on the LED induced fluorescence polarization to detect Ephedrine and Benzyl Methyl Keton (BMK) as a first approach. This technique is highly selective with respect to the target compounds due to the generation of properly engineered fluorescent proteins which are able to bind the target analytes, as it happens in an "immune-type reaction". This paper deals with the advances in the design, construction and validation of the LED induced fluorescence sensor to detect BMK analytes. This sensor includes an analysis module based on high performance LED and PMT detector, a fluidic system to dose suitable quantities of reagents and some printed circuit boards, all of them fixed in a small structure (167mm × 193mm × 228mm) with the capability of working as a stand-alone application.
Jong, Edmund C; Macek, Paul V; Perera, Inoka E; Luxbacher, Kray D; McNair, Harold M
2015-07-01
Sulfur hexafluoride (SF6) is widely used as a tracer gas because of its detectability at low concentrations. This attribute of SF6 allows the quantification of both small-scale flows, such as leakage, and large-scale flows, such as atmospheric currents. SF6's high detection sensitivity also facilitates greater usage efficiency and lower operating cost for tracer deployments by reducing quantity requirements. The detectability of SF6 is produced by its high molecular electronegativity. This property provides a high potential for negative ion formation through electron capture thus naturally translating to selective detection using negative ion chemical ionization mass spectrometry (NCI-MS). This paper investigates the potential of using gas chromatography (GC) with NCI-MS for the detection of SF6. The experimental parameters for an ultra-trace SF6 detection method utilizing minimal customizations of the analytical instrument are detailed. A method for the detection of parts per trillion (ppt) level concentrations of SF6 for the purpose of underground ventilation tracer gas analysis was successfully developed in this study. The method utilized a Shimadzu gas chromatography with negative ion chemical ionization mass spectrometry system equipped with an Agilent J&W HP-porous layer open tubular column coated with an alumina oxide (Al2O3) S column. The method detection limit (MDL) analysis as defined by the Environmental Protection Agency of the tracer data showed the method MDL to be 5.2 ppt. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Amran, Tengku Sarah Tengku; Ismail, Mohamad Pauzi; Ahmad, Mohamad Ridzuan; Amin, Mohamad Syafiq Mohd; Sani, Suhairy; Masenwat, Noor Azreen; Ismail, Mohd Azmi; Hamid, Shu-Hazri Abdul
2017-01-01
A water pipe is any pipe or tubes designed to transport and deliver water or treated drinking with appropriate quality, quantity and pressure to consumers. The varieties include large diameter main pipes, which supply entire towns, smaller branch lines that supply a street or group of buildings or small diameter pipes located within individual buildings. This distribution system (underground) is used to describe collectively the facilities used to supply water from its source to the point of usage. Therefore, a leaking in the underground water distribution piping system increases the likelihood of safe water leaving the source or treatment facility becoming contaminated before reaching the consumer. Most importantly, leaking can result in wastage of water which is precious natural resources. Furthermore, they create substantial damage to the transportation system and structure within urban and suburban environments. This paper presents a study on the possibility of using ground penetrating radar (GPR) with frequency of 1GHz to detect pipes and leakages in underground water distribution piping system. Series of laboratory experiment was designed to investigate the capability and efficiency of GPR in detecting underground pipes (metal and PVC) and water leakages. The data was divided into two parts: 1. detecting/locating underground water pipe, 2. detecting leakage of underground water pipe. Despite its simplicity, the attained data is proved to generate a satisfactory result indicating GPR is capable and efficient, in which it is able to detect the underground pipe and presence of leak of the underground pipe.
Kataoka, Tomoya; Hinata, Hirofumi; Kako, Shin'ichiro
2012-09-01
We have developed a technique for detecting the pixels of colored macro plastic debris (plastic pixels) using photographs taken by a webcam installed on Sodenohama beach, Tobishima Island, Japan. The technique involves generating color references using a uniform color space (CIELUV) to detect plastic pixels and removing misdetected pixels by applying a composite image method. This technique demonstrated superior performance in terms of detecting plastic pixels of various colors compared to the previous method which used the lightness values in the CIELUV color space. We also obtained a 10-month time series of the quantity of plastic debris by combining a projective transformation with this technique. By sequential monitoring of plastic debris quantity using webcams, it is possible to clean up beaches systematically, to clarify the transportation processes of plastic debris in oceans and coastal seas and to estimate accumulation rates on beaches. Copyright © 2012 Elsevier Ltd. All rights reserved.
Effects of 2 adenosine antagonists, quercetin and caffeine, on vigilance and mood.
Olson, Craig A; Thornton, Jennifer A; Adam, Gina E; Lieberman, Harris R
2010-10-01
Quercetin, a phenolic flavonoid found in small quantities in some fruits and vegetables, is an adenosine receptor antagonist in vitro marketed as a dietary supplement for purported caffeine-like effects. A double-blind, placebo-controlled, between-subjects study was conducted to compare the behavioral effects of quercetin to a central adenosine receptor antagonist, caffeine. Fifty-seven volunteers received either 2000 mg of quercetin dihydrate (a dose estimated based on in vitro receptor binding to be equivalent in potency to 200 mg of caffeine), placebo, or 200 mg of caffeine. One hour later, a 45-minute visual vigilance task was administered. The Profile of Mood States questionnaire was completed before treatment and immediately after vigilance testing. On the vigilance task, caffeine increased the number of stimuli detected (P < 0.02) and decreased the reaction time (P = 0.001). Caffeine increased self-reported vigor and reduced fatigue and total mood disturbance Profile of Mood States scores compared with placebo. Quercetin did not significantly alter any parameter, but values were typically intermediate between caffeine and placebo on those tests affected by caffeine. Quercetin is unlikely to have any effects when consumed by humans in quantities present in the diet or in dietary supplements. Caffeine (200 mg) administration resulted in the expected effects on vigilance and mood.
Determination of picomole quantities of acetylcholine and choline in physiologic salt solutions.
Gilberstadt, M L; Russell, J A
1984-04-01
An assay capable of detecting tens-of-picomole quantities of choline and acetylcholine in milliliter volumes of a physiological salt solution has been developed. Silica column chromatography was used to bind and separate 10-3000 pmol [14C]choline and [14C]acetylcholine standards made up in 3 ml of a bicarbonate-buffered Krebs-Ringer solution. The silica columns bound 95-98% of both choline and acetylcholine. Of the bound choline 84-87% was eluted in 1.5 ml of 0.075 N HCl, whereas 95-98% of the bound acetylcholine was eluted in a subsequent wash with 1.5 ml of 0.030 N HCl in 10% 2-butanone. Vacuum centrifugation of the eluants yielded small white pellets with losses of choline and acetylcholine of only 1%. Dried pellets of unlabeled choline and acetylcholine standards were assayed radioenzymatically using [gamma-32P]ATP, choline kinase, and acetylcholinesterase. The net disintegrations per minute of choline[32P]phosphate product was proportional to both the acetylcholine (10-3000 pmol) and choline (30-3000 pmol) standards. The "limit sensitivity" was 8.5 pmol for acetylcholine and 11.4 pmol for choline. Cross-contamination of the choline assay by acetylcholine averaged 1.3%, whereas contamination of the acetylcholine assay by choline averaged 3.1%.
[Effects of small hydropower substitute fuel project on forest ecosystem services].
Yu, Hai Yan; Zha, Tong Gang; Nie, Li Shui; Lyu, Zhi Yuan
2016-10-01
Based on the Forest Ecosystem Services Assessment Standards (LY/T 1721-2008) issued by the State Forestry Administration, this paper evaluated four key functions of forest ecosystems, i.e., water conservation, soil conservation, carbon fixation and oxygen release, and nutrient accumulation. Focusing on the project area of Majiang County in Guizhou Province, this study provided some quantitative evidence that the implementation of the small hydropower substituting fuel project had positive effects on the values and material quantities of ecosystem service functions. The results showed that the small hydropower substituting fuel project had a significant effect on the increase of forest ecosystem services. Water conservation quantity of Pinus massoniana and Cupressus funebris plantations inside project area was 20662.04 m 3 ·hm -2 ·a -1 , 20.5% higher than outside project area, with soil conservation quantity of 119.1 t·hm -2 ·a -1 , 29.7% higher than outside project area, carbon fixation and oxygen release of 220.49 t·hm -2 ·a -1 , 40.2% higher than outside project area, and forest tree nutrition accumulation of 3.49 t·hm -2 ·a -1 , 48.5% higher than outside project area. Small hydropower substituting fuel project for increasing the quota of forest ecosystem service function value was in the order of carbon fixation and oxygen release function (71400 yuan·hm -2 ·a -1 ) > water conservation function (60100 yuan·hm -2 ·a -1 ) > tree nutrition accumulation function (13800 yuan·hm -2 ·a -1 ) > soil conservation function (8100 yuan·hm -2 ·a -1 ). Small hydropower substituting fuel project played an important role for improving the forest ecological service function value and realizing the sustainable development of forest.
Hammersvik, Eirik; Sandberg, Sveinung; Pedersen, Willy
2012-11-01
Over the past 15-20 years, domestic cultivation of cannabis has been established in a number of European countries. New techniques have made such cultivation easier; however, the bulk of growers remain small-scale. In this study, we explore the factors that prevent small-scale growers from increasing their production. The study is based on 1 year of ethnographic fieldwork and qualitative interviews conducted with 45 Norwegian cannabis growers, 10 of whom were growing on a large-scale and 35 on a small-scale. The study identifies five mechanisms that prevent small-scale indoor growers from going large-scale. First, large-scale operations involve a number of people, large sums of money, a high work-load and a high risk of detection, and thus demand a higher level of organizational skills than for small growing operations. Second, financial assets are needed to start a large 'grow-site'. Housing rent, electricity, equipment and nutrients are expensive. Third, to be able to sell large quantities of cannabis, growers need access to an illegal distribution network and knowledge of how to act according to black market norms and structures. Fourth, large-scale operations require advanced horticultural skills to maximize yield and quality, which demands greater skills and knowledge than does small-scale cultivation. Fifth, small-scale growers are often embedded in the 'cannabis culture', which emphasizes anti-commercialism, anti-violence and ecological and community values. Hence, starting up large-scale production will imply having to renegotiate or abandon these values. Going from small- to large-scale cannabis production is a demanding task-ideologically, technically, economically and personally. The many obstacles that small-scale growers face and the lack of interest and motivation for going large-scale suggest that the risk of a 'slippery slope' from small-scale to large-scale growing is limited. Possible political implications of the findings are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.
Forecasting Science and Technology for the Department of Defense
2009-12-01
Watson and Francis Crick announced that they had elucidated the structure of DNA and had therefore “discovered the secret of life.” While this was a...an organic chemist, figured out a process by which very small quantities of DNA could be amplified with high fidelity. This process, known as...polymerase chain reaction (PCR), for the first time, allowed scientists to produce DNA in large quantities. Roughly during this period, Leroy Hood and
Hansen, Mark; Howd, Peter; Sallenger, Asbury; Wright, C. Wayne; Lillycrop, Jeff
2007-01-01
Hurricane Katrina severely impacted coastal Mississippi, creating large quantities of building and vegetation debris. This paper summarizes techniques to estimate vegetation and nonvegetation debris quantities from light detection and ranging (lidar) data and presents debris volume results for Harrison County, Miss.
Comparative quantification of human intestinal bacteria based on cPCR and LDR/LCR
Tang, Zhou-Rui; Li, Kai; Zhou, Yu-Xun; Xiao, Zhen-Xian; Xiao, Jun-Hua; Huang, Rui; Gu, Guo-Hao
2012-01-01
AIM: To establish a multiple detection method based on comparative polymerase chain reaction (cPCR) and ligase detection reaction (LDR)/ligase chain reaction (LCR) to quantify the intestinal bacterial components. METHODS: Comparative quantification of 16S rDNAs from different intestinal bacterial components was used to quantify multiple intestinal bacteria. The 16S rDNAs of different bacteria were amplified simultaneously by cPCR. The LDR/LCR was examined to actualize the genotyping and quantification. Two beneficial (Bifidobacterium, Lactobacillus) and three conditionally pathogenic bacteria (Enterococcus, Enterobacterium and Eubacterium) were used in this detection. With cloned standard bacterial 16S rDNAs, standard curves were prepared to validate the quantitative relations between the ratio of original concentrations of two templates and the ratio of the fluorescence signals of their final ligation products. The internal controls were added to monitor the whole detection flow. The quantity ratio between two bacteria was tested. RESULTS: cPCR and LDR revealed obvious linear correlations with standard DNAs, but cPCR and LCR did not. In the sample test, the distributions of the quantity ratio between each two bacterial species were obtained. There were significant differences among these distributions in the total samples. But these distributions of quantity ratio of each two bacteria remained stable among groups divided by age or sex. CONCLUSION: The detection method in this study can be used to conduct multiple intestinal bacteria genotyping and quantification, and to monitor the human intestinal health status as well. PMID:22294830
Comparative quantification of human intestinal bacteria based on cPCR and LDR/LCR.
Tang, Zhou-Rui; Li, Kai; Zhou, Yu-Xun; Xiao, Zhen-Xian; Xiao, Jun-Hua; Huang, Rui; Gu, Guo-Hao
2012-01-21
To establish a multiple detection method based on comparative polymerase chain reaction (cPCR) and ligase detection reaction (LDR)/ligase chain reaction (LCR) to quantify the intestinal bacterial components. Comparative quantification of 16S rDNAs from different intestinal bacterial components was used to quantify multiple intestinal bacteria. The 16S rDNAs of different bacteria were amplified simultaneously by cPCR. The LDR/LCR was examined to actualize the genotyping and quantification. Two beneficial (Bifidobacterium, Lactobacillus) and three conditionally pathogenic bacteria (Enterococcus, Enterobacterium and Eubacterium) were used in this detection. With cloned standard bacterial 16S rDNAs, standard curves were prepared to validate the quantitative relations between the ratio of original concentrations of two templates and the ratio of the fluorescence signals of their final ligation products. The internal controls were added to monitor the whole detection flow. The quantity ratio between two bacteria was tested. cPCR and LDR revealed obvious linear correlations with standard DNAs, but cPCR and LCR did not. In the sample test, the distributions of the quantity ratio between each two bacterial species were obtained. There were significant differences among these distributions in the total samples. But these distributions of quantity ratio of each two bacteria remained stable among groups divided by age or sex. The detection method in this study can be used to conduct multiple intestinal bacteria genotyping and quantification, and to monitor the human intestinal health status as well.
Preparation of 152Gd targets from a small quantity of gadolinium oxide in a pyrochemical reaction
NASA Astrophysics Data System (ADS)
Lipski, A. R.
1995-02-01
A simple method utilizing small amounts (< 5 mg) of isotopically enriched material for the production of gadolinium targets is discussed. An electrostatically focused e-gun is used in the procedure in which 152Gd 2O 3 powder undergoes reduction-distillation and deposition onto an Fe foil.
Preparation of isotopic molybdenum foils utilizing small quantities of material
NASA Astrophysics Data System (ADS)
Lipski, A. R.; Lee, L. L.; Liang, J. F.; Mahon, J. C.
1993-09-01
A simple method utilizing a small amount of isotopic material for production of molybdenum foils is discussed. An e-gun is used in the procedure. The Mo powder undergoes reduction-sintering and melting-solidifying steps leading to the creation of a metallic droplet suitable for further cold rolling or vacuum deposition.
Measuring Very Small Quantities: Fascinating Suggestions for Math or Science.
ERIC Educational Resources Information Center
Thompson, John Taylor
1989-01-01
Described are several activities for teaching children to determine mass and volume. Included are the masses of a water drop and a grain of rice; the volume of a water drop and small solids; and measuring the width of a hair. Procedures and materials for the activities are discussed. (CW)
A New Synthesis of Tertiary Alkyl N-Arylcarbamates from Isocyanates.
ERIC Educational Resources Information Center
Bailey, William J.; Griffith, James R.
1978-01-01
The method involves the dissolution of a small piece of metallic lithium in a small quantity of tertiary alcohol followed by addition to a mixture of the isocyanate and the tertiary alcohol in ether. This should be useful in organic chemistry laboratory courses for the identification of tertiary alcohols. (Author/BB)
29 CFR 779.367 - Commercial stationers may qualify as exempt 13(a)(2) establishments.
Code of Federal Regulations, 2014 CFR
2014-07-01
... typewriters and certain other small office machines. (b) In determining whether, under the 13(a)(2) exemption... well as businesses, including typewriters, adding machines, small duplicating machines, checkwriters... contractual arrangement involving the sale of a large quantity of goods over a period of time with a...
NASA Astrophysics Data System (ADS)
Synovec, Robert E.; Renn, Curtiss N.
1991-07-01
The refractive index gradient (RIG) of hydrodynamically controlled profiles can be universally, yet sensitively, measured by carefully probing the radial RIG passing through a z-configuration flow cell. Fiber optic technology is applied in order to provide a narrow, collimated probe beam (100 micrometers diameter) that is deflected by a RIG and measured by a position sensitive detector. The fiber optic construction allows one to probe very small volumes (1 (mu) L to 3 (mu) L) amenable to microbore liquid chromatography ((mu) LC). The combination of (mu) LC and RIG detection is very useful for the analysis of trace quantities (ng injected amounts) of chemical species that are generally difficult to measure, i.e., species that are not amenable to absorbance detection or related techniques. Furthermore, the RIG detector is compatible with conventional mobile phase gradient and thermal gradient (mu) LC, unlike traditional RI detectors. A description of the RIG detector coupled with (mu) LC for the analysis of complex polymer samples is reported. Also, exploration into using the RIG detector for supercritical fluid chromatography is addressed.
Molecular diagnostics of periodontitis.
Korona-Głowniak, Izabela; Siwiec, Radosław; Berger, Marcin; Malm, Anna; Szymańska, Jolanta
2017-01-28
The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host's health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization) come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR), real-time polymerase chain reaction (real-time PCR), 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE), temperature gradient gel electrophoresis (TGGE), as well as terminal restriction fragment length polymorphism (TRFLP) and next generation sequencing (NGS). The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.
Roscioli, Kristyn M; Tufariello, Jessica A; Zhang, Xing; Li, Shelly X; Goetz, Gilles H; Cheng, Guilong; Siems, William F; Hill, Herbert H
2014-04-07
Desorption electrospray ionization (DESI) was coupled to an ambient pressure drift tube ion mobility time-of-flight mass spectrometer (IM-TOFMS) for the direct analysis of active ingredients in pharmaceutical samples. The DESI source was also coupled with a standalone IMS demonstrating potential of portable and inexpensive drug-quality testing platforms. The DESI-IMS required no sample pretreatment as ions were generated directly from tablets and cream formulations. The analysis of a range of over-the-counter and prescription tablet formations was demonstrated for amphetamine (methylphenidate), antidepressant (venlafaxine), barbiturate (Barbituric acid), depressant (alprazolam), narcotic (3-methylmorphine) and sympatholytic (propranolol) drugs. Active ingredients from soft and liquid formulations, such as Icy Hot cream (methyl salicylate) and Nyquil cold medicine (acetaminophen, dextromethorphan, doxylamine) were also detected. Increased sensitivity for selective drug responses was demonstrated through the formation of sodiated adduct ions by introducing small quantities of NaCl into the DESI solvent. Of the drugs and pharmaceuticals tested in this study, 68% (22 total samples) provided a clear ion mobility response at characteristic mobilities either as (M + H)(+), (M - H)(-), or (M + Na)(+) ions.
Trouillon, Raphaël; Lin, Yuqing; Mellander, Lisa J; Keighron, Jacqueline D; Ewing, Andrew G
2013-07-02
During exocytosis, small quantities of neurotransmitters are released by the cell. These neurotransmitters can be detected quantitatively using electrochemical methods, principally with disk carbon fiber microelectrode amperometry. An exocytotic event then results in the recording of a current peak whose characteristic features are directly related to the mechanisms of exocytosis. We have compared two exocytotic peak populations obtained from PC12 cells with a disk carbon fiber microelectrode and with a pyrolyzed carbon ring microelectrode array, with a 500 nm ring thickness. The specific shape of the ring electrode allows for precise analysis of diffusion processes at the vicinity of the cell membrane. Peaks obtained with a ring microelectrode array show a distorted average shape, owing to increased diffusion pathways. This result has been used to evaluate the diffusion coefficient of dopamine at the surface of a cell, which is up to an order of magnitude smaller than that measured in free buffer. The lower rate of diffusion is discussed as resulting from interactions with the glycocalyx.
Correlation of glucosinolate content to myrosinase activity in horseradish (Armoracia rusticana).
Li, Xian; Kushad, Mosbah M
2004-11-17
Fully developed horseradish (Armoracia rusticana Gaertn., Mey., & Scherb.) roots from 27 accessions and leaves from a subset of 9 accessions were evaluated for glucosinolates and myrosinase enzyme activity. Eight different glucosinolates were detected (based on HPLC retention times as desulfoglucosinolates) in both root and leaf tissues. The sum of these glucosinolates, referred to as total, ranged from 2 to 296 micromol g(-1) of dry weight (DW) in both tissues. Four glucosinolates (sinigrin, glucobrassicin, neoglucobrassicin, and gluconasturtiin) were detected in major quantities. In fully developed roots, sinigrin concentration represented approximately 83%, gluconasturtiin approximately 11%, and glucobrassicin approximately 1% of the total glucosinolates. Approximately the same proportions of individual glucosinolates appeared in fully developed leaves, except that glucobrassicin was substituted by neoglucobrassicin and gluconasturtiin concentration was significantly lower (<1%). At least four other glucosinolates were detected in very small quantities (<1%) in both roots and leaves. Myrosinase (beta-thioglucoside glucohydrolase, EC 3.2.3.1) is the enzyme responsible for the hydrolysis of the parent glucosinolates into biologically active products. Very little is known about myrosinase activity and the correlation of its activity to total and individual glucosinolates in plant tissues. Significant differences in myrosinase activity were detected between the roots and leaves, ranging from 1.2 to 57.1 units g(-1) of DW. Data showed no correlation between myrosinase activity and total and/or individual glucosinolates in the roots. However, in the leaves, significant correlations were found between myrosinase activity and total glucosinolates (0.78 at P = 0.01) and between myrosinase activity and sinigrin (0.80 at P = 0.01). Glucosinolates content and myrosinase activity were also correlated in young and fully developed roots and leaves and during tissue crushing. Glucobrassicin concentration in the roots and neoglucobrassicin concentration in the leaves were significantly higher in young than in fully developed tissue. Crushing of the tissue resulted in rapid hydrolysis of sinigrin and glucobrassicin, as expected, from the presence of myrosinase. Likewise, myrosinase activity declined rapidly after crushing, perhaps due to inactivation by the reaction products and/or the depletion of its substrates.
Flight assessment of an atmospheric turbulence measurement system with emphasis on long wavelengths
NASA Technical Reports Server (NTRS)
Rhyne, R. H.
1976-01-01
A flight assessment has been made of a system for measuring the three components of atmospheric turbulence in the frequency range associated with airplane motions (0 to approximately 0.5 Hz). Results of the assessment indicate acceptable accuracy of the resulting time histories and power spectra. Small residual errors at the airplane short period and Dutch roll frequencies (0.5 and 0.25 Hz, respectively), as determined from in-flight maneuvers in smooth air, would not be detectable on the power spectra. However, errors at approximately 0.25 Hz can be present in the time history of the lateral turbulence component, particularly at the higher altitudes where airplane yawing motions are large. An assessment of the quantities comprising the vertical turbulence component leads to the conclusion that the vertical component is essentially accurate to zero frequency.
Millimeter-Wave Chemical Sensor Using Substrate-Integrated-Waveguide Cavity
Memon, Muhammad Usman; Lim, Sungjoon
2016-01-01
This research proposes a substrate-integrated waveguide (SIW) cavity sensor to detect several chemicals using the millimeter-wave frequency range. The frequency response of the presented SIW sensor is switched by filling a very small quantity of chemical inside of the fluidic channel, which also causes a difference in the effective permittivity. The fluidic channel on this structure is either empty or filled with a chemical; when it is empty the structure resonates at 17.08 GHz. There is always a different resonant frequency when any chemical is injected into the fluidic channel. The maximum amount of chemical after injection is held in the center of the SIW structure, which has the maximum magnitude of the electric field distribution. Thus, the objective of sensing chemicals in this research is achieved by perturbing the electric fields of the SIW structure. PMID:27809240
Carrasco Pancorbo, Alegría; Cruces-Blanco, Carmen; Segura Carretero, Antonio; Fernández Gutiérrez, Alberto
2004-11-03
A sensitive, rapid, efficient, and reliable method for the separation and determination of phenolic acids by capillary zone electrophoresis has been carried out. A detailed method optimization was carried out to separate 14 different compounds by studying parameters such as pH, type and concentration of buffer, applied voltage, and injection time. The separation was performed within 16 min, using a 25 mM sodium borate buffer (pH 9.6) at 25 kV with 8 s of hydrodynamic injection. With this method and using a liquid-liquid extraction system, with recovery values around 95%, it has been possible to detect small quantities of phenolic acids in olive oil samples. This is apparently the first paper showing the quantification of this specific family of phenolic compounds in virgin olive oil samples.
Miniaturized flow injection analysis system
Folta, James A.
1997-01-01
A chemical analysis technique known as flow injection analysis, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38.times.25.times.3 mm, but can be designed for gas analysis and be substantially smaller in construction.
Mechanism for detecting NAPL using electrical resistivity imaging.
Halihan, Todd; Sefa, Valina; Sale, Tom; Lyverse, Mark
2017-10-01
The detection of non-aqueous phase liquid (NAPL) related impacts in freshwater environments by electrical resistivity imaging (ERI) has been clearly demonstrated in field conditions, but the mechanism generating the resistive signature is poorly understood. An electrical barrier mechanism which allows for detecting NAPLs with ERI is tested by developing a theoretical basis for the mechanism, testing the mechanism in a two-dimensional sand tank with ERI, and performing forward modeling of the laboratory experiment. The NAPL barrier theory assumes at low bulk soil NAPL concentrations, thin saturated NAPL barriers can block pore throats and generate a detectable electrically resistive signal. The sand tank experiment utilized a photographic technique to quantify petroleum saturation, and to help determine whether ERI can detect and quantify NAPL across the water table. This experiment demonstrates electrical imaging methods can detect small quantities of NAPL of sufficient thickness in formations. The bulk volume of NAPL is not the controlling variable for the amount of resistivity signal generated. The resistivity signal is primarily due to a zone of high resistivity separate phase liquid blocking current flow through the fully NAPL saturated pores spaces. For the conditions in this tank experiment, NAPL thicknesses of 3.3cm and higher in the formation was the threshold for detectable changes in resistivity of 3% and greater. The maximum change in resistivity due to the presence of NAPL was an increase of 37%. Forward resistivity models of the experiment confirm the barrier mechanism theory for the tank experiment. Copyright © 2017 Elsevier B.V. All rights reserved.
Natsuike, Masafumi; Saito, Rui; Fujiwara, Amane; Matsuno, Kohei; Yamaguchi, Atsushi; Shiga, Naonobu; Hirawake, Toru; Kikuchi, Takashi; Nishino, Shigeto; Imai, Ichiro
2017-01-01
The eastern Bering Sea has a vast continental shelf, which contains various endangered marine mammals and large fishery resources. Recently, high numbers of toxic A. tamarense resting cysts were found in the bottom sediment surface of the eastern Bering Sea shelf, suggesting that the blooms have recently occurred. However, little is known about the presence of A. tamarense vegetative cells in the eastern Bering Sea. This study's goals were to detect the occurrence of A. tamarense vegetative cells on the eastern Bering Sea shelf and to find a relationship between environmental factors and their presence. Inter-annual field surveys were conducted to detect A. tamarense cells and environmental factors, such as nutrients, salinity, chlorophyll a, and water temperature, along a transect line on the eastern Bering Sea shelf during the summers of 2004, 2005, 2006, 2009, 2012, and 2013. A. tamarense vegetative cells were detected during every sampling year, and their quantities varied greatly from year to year. The maximum cell densities of A. tamarense observed during the summers of 2004 and 2005 were much higher than the Paralytic shellfish poisoning warning levels, which are greater than 100-1,000 cells L-1, in other subarctic areas. Lower quantities of the species occurred during the summers of 2009, 2012, and 2013. A significant positive correlation between A. tamarense quantity and water temperature and significant negative correlations between A. tamarense quantity and nutrient concentrations (of phosphate, silicate, and nitrite and nitrate) were detected in every sampling period. The surface- and bottom-water temperatures varied significantly from year to year, suggesting that water temperatures, which have been known to affect the cell growth and cyst germination of A. tamarense, might have affected the cells' quantities in the eastern Bering Sea each summer. Thus, an increase in the Bering Sea shelf's water temperature during the summer will increase the frequency and scale of toxic blooms and the toxin contamination of plankton feeders. This poses serious threats to humans and the marine ecosystem.
At Birth, Humans Associate "Few" with Left and "Many" with Right.
de Hevia, Maria Dolores; Veggiotti, Ludovica; Streri, Arlette; Bonn, Cory D
2017-12-18
Humans use spatial representations to structure abstract concepts [1]. One of the most well-known examples is the "mental number line"-the propensity to imagine numbers oriented in space [2, 3]. Human infants [4, 5], children [6, 7], adults [8], and nonhuman animals [9, 10] associate small numbers with the left side of space and large numbers with the right. In humans, cultural artifacts, such as the direction of reading and writing, modulate the directionality of this representation, with right-to-left reading cultures associating small numbers with right and large numbers with left [11], whereas the opposite association permeates left-to-right reading cultures [8]. Number-space mapping plays a central role in human mathematical concepts [12], but its origins remain unclear: is it the result of an innate bias or does it develop after birth? Infant humans are passively exposed to a spatially coded environment, so experience and culture could underlie the mental number line. To rule out this possibility, we tested neonates' responses to small or large auditory quantities paired with geometric figures presented on either the left or right sides of the screen. We show that 0- to 3-day-old neonates associate a small quantity with the left and a large quantity with the right when the multidimensional stimulus contains discrete numerical information, providing evidence that representations of number are associated to an oriented space at the start of postnatal life, prior to experience with language, culture, or with culture-specific biases. Copyright © 2017 Elsevier Ltd. All rights reserved.
Peanut allergens are rapidly transferred in human breast milk and can prevent sensitization in mice.
Bernard, H; Ah-Leung, S; Drumare, M-F; Feraudet-Tarisse, C; Verhasselt, V; Wal, J-M; Créminon, C; Adel-Patient, K
2014-07-01
Food allergens have been evidenced in breast milk under physiological conditions, but the kinetic and the role of this passage in food allergies are still unclear. We then aimed to analyze the passage of peanut allergens in human breast milk and their allergenicity/immunomodulatory properties. Human breast milk was collected from two non-atopic peanut-tolerant mothers before and at different time points after ingestion of 30 g of commercial roasted peanut. Ara h 6, Ara h 6 immune complexes, and the IgE binding capacity of breast milk samples were measured using specific immunoassays. Their allergenic functionality was then assessed using cell-based assay. Finally, human breast milk obtained before or after peanut ingestion was administered intragastrically to BALB/c mice at different ages, and mice were further experimentally sensitized to peanut using cholera toxin. Ara h 6 is detected as soon as 10 min after peanut ingestion, with peak values observed within the first hour after ingestion. The transfer is long-lasting, small quantities of peanut allergens being detected over a 24-h period. IgG-Ara h 6 and IgA-Ara h 6 immune complexes are evidenced, following a different kinetic of excretion than free allergens. Peanut allergens transferred in milk are IgE reactive and can induce an allergic reaction in vitro. However, administration of human breast milk to young mice, notably before weaning, does not lead to sensitization, but instead to partial oral tolerance. The low quantities of immunologically active allergens transferred through breast milk may prevent instead of priming allergic sensitization to peanut. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cost estimating Brayton and Stirling engines
NASA Technical Reports Server (NTRS)
Fortgang, H. R.
1980-01-01
Brayton and Stirling engines were analyzed for cost and selling price for production quantities ranging from 1000 to 400,000 units per year. Parts and components were subjected to indepth scrutiny to determine optimum manufacturing processes coupled with make or buy decisions on materials and small parts. Tooling and capital equipment costs were estimated for each detail and/or assembly. For low annual production volumes, the Brayton engine appears to have a lower cost and selling price than the Stirling Engine. As annual production quantities increase, the Stirling becomes a lower cost engine than the Brayton. Both engines could benefit cost wise if changes were made in materials, design and manufacturing process as annual production quantities increase.
Johnny Boggs; Ge Sun; Steven McNulty
2015-01-01
This paired watershed study tested the effects of timber harvest on water quantity and quality in the North Carolina Piedmont physiographic region. Four headwater watersheds at Hill Demonstration Forest (HF1, HF2, HFW1, and HFW2) and two at Umstead Research Farm (UF1 and UF2) were continuously monitored for discharge and water quality from 2007 to 2013. The HF1 and UF1...
Prospects for P-bearing molecules in cometary atmospheres
NASA Astrophysics Data System (ADS)
Boice, Daniel; de Almeida, Amaury
Phosphorus is a key element in all known forms of life and phosphorus-bearing compounds have been observed in space. Phosphorus is ubiquitous in meteorites, albeit in small quantities, with phosphates being found in stoney meteorites and phosphides have been identified in iron meteorites. It has been detected as part of the dust component in comet Halley but searches for P-bearing species in the gas phase in comets have been unsuccessful. Based of its moderate cosmic abundance (eighteenth most abundant element, [P]/[N] = 4 x 10-3 ) and the positive identification of P-bearing species in the interstellar medium (such as, PN, PC, HCP and PO), we would expect simple molecules, diatomics (like PH, PO, PC, PS), triatomics (like HCP and PH2 ), and possibly other polyatomics (like phosphine PH3 and diphosphine P2 H4 ), to exist in cometary ices, hence released into the gas phase upon ice sublimation. Our fluid dynamics model with chemistry of cometary comae (SUISEI) has been adapted to study this problem. SUISEI produces cometocentric abundances of the coma gas species; velocities of the bulk gas, light atomic and molecular hydrogen with escape, and electrons; gas and electron temperatures; column densities to facilitate comparison with observations; coma energy budget quantities; attenuation of the solar irradiance; and other quantities that can be related readily to observations. We present results from the first quantitative study of phosphorus-bearing molecules in comets to identify likely species containing phosphorus to aid in future searches for this important element in comets, possibly shedding light on issues of comet formation (time and place) and matters of the prebiotic to biotic evolution of life. Acknowledgements. This work was supported by the NSF Planetary Astronomy Program.
Nonconservative and reverse spectral transfer in Hasegawa-Mima turbulence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terry, P.W.; Newman, D.E.
1993-01-01
The dual cascade is generally represented as a conservative cascade of enstrophy to short wavelengths through an enstrophy similarity range and an inverse cascade of energy to long wavelengths through an energy similarity range. This picture, based on a proof due to Kraichnan [Phys. Fluids 10, 1417 (1967)], is found to be significantly modified for a spectra of finite extent. Dimensional arguments and direct measurement of spectral flow in Hasegawa-Mima turbulence indicate that for both the energy and enstrophy cascades, transfer of the conserved quantity is accompanied by a nonconservative transfer of the other quantity. The decrease of a givenmore » invariant (energy or enstrophy) in the nonconservative transfer in one similarity range is balanced by the increase of that quantity in the other similarity range, thus maintaining net invariance. The increase or decrease of a given invariant quantity in one similarity range depends on the injection scale and is consistent with that quantity being carried in a self-similar transfer of the other invariant quantity. This leads, in an inertial range of finite size, to some energy being carried to small scales and some enstrophy being carried to large scales.« less
Nonconservative and reverse spectral transfer in Hasegawa--Mima turbulence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terry, P.W.; Newman, D.E.
1993-07-01
The dual cascade is generally represented as a conservative cascade of enstrophy to short wavelengths through an enstrophy similarity range and an inverse cascade of energy to long wavelengths through an energy similarity range. This picture, based on a proof due to Kraichnan [Phys. Fluids [bold 10], 1417 (1967)], is found to be significantly modified for spectra of finite extent. Dimensional arguments and direct measurement of spectral flow in Hasegawa--Mima turbulence indicate that for both the energy and enstrophy cascades, transfer of the conserved quantity is accompanied by a nonconservative transfer of the other quantity. The decrease of a givenmore » invariant (energy or enstrophy) in the nonconservative transfer in one similarity range is balanced by the increase of that quantity in the other similarity range, thus maintaining net invariance. The increase or decrease of a given invariant quantity in one similarity range depends on the injection scale and is consistent with that quantity being carried in a self-similar transfer of the other invariant quantity. This leads, in an inertial range of finite size, to some energy being carried to small scales and some enstrophy being carried to large scales.« less
Fluid-dynamically coupled solid propellant combustion instability - cold flow simulation
NASA Astrophysics Data System (ADS)
Ben-Reuven, M.
1983-10-01
The near-wall processes in an injected, axisymmetric, viscous flow is examined. Solid propellant rocket instability, in which cold flow simulation is evaluated as a tool to elucidate possible instability driving mechanisms is studied. One such prominent mechanism seems to be visco-acoustic coupling. The formulation is presented in terms of a singular boundary layer problem, with detail (up to second order) given only to the near wall region. The injection Reynolds number is assumed large, and its inverse square root serves as an appropriate small perturbation quantity. The injected Mach number is also small, and taken of the same order as the aforesaid small quantity. The radial-dependence of the inner solutions up to second order is solved, in polynominal form. This leaves the (x,t) dependence to much simpler partial differential equations. Particular results demonstrate the existence of a first order pressure perturbation, which arises due to the dissipative near wall processes. This pressure and the associated viscous friction coefficient are shown to agree very well with experimental injected flow data.
Long-term retrievability and safeguards for immobilized weapons plutonium in geologic storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, P.F.
1996-05-01
If plutonium is not ultimately used as an energy source, the quantity of excess weapons plutonium (w-Pu) that would go into a US repository will be small compared to the quantity of plutonium contained in the commercial spent fuel in the repository, and the US repository(ies) will likely be only one (or two) locations out of many around the world where commercial spent fuel will be stored. Therefore excess weapons plutonium creates a small perturbation to the long-term (over 200,000 yr) global safeguard requirements for spent fuel. There are details in the differences between spent fuel and immobilized w-Pu wastemore » forms (i.e. chemical separation methods, utility for weapons, nuclear testing requirements), but these are sufficiently small to be unlikely to play a significant role in any US political decision to rebuild weapons inventories, or to change the long-term risks of theft by subnational groups.« less
Presidential Green Chemistry Challenge: 2011 Small Business Award
Presidential Green Chemistry Challenge 2011 award winner, BioAmber, developed an integrated technology to produce large, commercial quantities of succinic acid by bacterial fermentation, replacing petroleum-based feedstocks.
Micro-quantity tissue digestion for metal measurements by use of a microwave acid-digestion bomb.
Nicholson, J R; Savory, M G; Savory, J; Wills, M R
1989-03-01
We describe a simple and convenient method for processing small amounts of tissue samples for trace-metal measurements by atomic absorption spectrometry, by use of a modified Parr microwave digestion bomb. Digestion proceeds rapidly (less than or equal to 90 s) in a sealed Teflon-lined vessel that eliminates contamination or loss from volatilization. Small quantities of tissue (5-100 mg dry weight) are digested in high-purity nitric acid, yielding concentrations of analyte that can be measured directly without further sample manipulation. We analyzed National Institute of Standards and Technology bovine liver Standard Reference Material to verify the accuracy of the technique. We assessed the applicability of the technique to analysis for aluminum in bone by comparison with a dry ashing procedure.
Detection and Measurement of Micrometeoroids with LISA Pathfinder
NASA Technical Reports Server (NTRS)
Thorpe, J. I.; Parvini, C.; Trigo-Rodriguez, J. M.
2016-01-01
The Solar System contains a population of dust and small particles originating from asteroids, comets, and other bodies. These particles have been studied using a number of techniques ranging from in-situ satellite detectors to analysis of lunar microcraters to ground-based observations of zodiacal light. In this paper, we describe an approach for using the LISA Pathfinder (LPF) mission as an instrument to detect and characterize the dynamics of dust particles in the vicinity of Earth-Sun L1. Launched on Dec. 3rd, 2015, LPF is a dedicated technology demonstrator mission that will validate several key technologies for a future space-based gravitational-wave observatory. The primary science instrument aboard LPF is a precision accelerometer which we show will be capable of sensing discrete momentum impulses as small as 4 x 10(exp -8) N s.We then estimate the rate of such impulses resulting from impacts of micrometeoroids based on standard models of the micrometeoroid environment in the inner solar system. We find that LPF may detect dozens to hundreds of individual events corresponding to impacts of particles with masses greater than 10(exp -9) g during LPF's roughly six-month science operations phase in a 5 x 10(exp 5) km by 8 x 10(exp 5) km Lissajous orbit around L1. In addition, we estimate the ability of LPF to characterize individual impacts by measuring quantities such as total momentum transferred, direction of impact, and location of impact on the spacecraft. Information on flux and direction provided by LPF may provide insight as to the nature and origin of the individual impact and help constrain models of the interplanetary dust complex in general. Additionally, this direct in situ measurement of micrometeoroid impacts will be valuable to designers of future spacecraft targeting the environment around L1.
Koc, Anna; Cañuelo, Ana; Garcia-Reyes, Juan F; Molina-Diaz, Antonio; Trojanowicz, Marek
2012-06-01
In this work, the use of liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC-TOFMS) has been evaluated for the profiling of relatively low-molecular weight protein species in both genetically modified (GM) and non-GM maize. The proposed approach consisted of a straightforward sample fractionation with different water and ethanol-based buffer solutions followed by separation and detection of the protein species using liquid chromatography with a small particle size (1.8 μm) C(18) column and electrospray-time-of-flight mass spectrometry detection in the positive ionization mode. The fractionation of maize reference material containing different content of transgenic material (from 0 to 5% GM) led to five different fractions (albumins, globulins, zeins, zein-like glutelins, and glutelins), all of them containing different protein species (from 2 to 52 different species in each fraction). Some relevant differences in the quantity and types of protein species were observed in the different fractions of the reference material (with different GM contents) tested, thus revealing the potential use of the proposed approach for fast protein profiling and to detect tentative GMO markers in maize. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Potential for detection of explosive and biological hazards with electronic terahertz systems.
Choi, Min Ki; Bettermann, Alan; van der Weide, D W
2004-02-15
The terahertz (THz) regime (0.1-10 THz) is rich with emerging possibilities in sensing, imaging and communications, with unique applications to screening for weapons, explosives and biohazards, imaging of concealed objects, water content and skin. Here we present initial surveys to evaluate the possibility of sensing plastic explosives and bacterial spores using field-deployable electronic THz techniques based on short-pulse generation and coherent detection using nonlinear transmission lines and diode sampling bridges. We also review the barriers and approaches to achieving greater sensing-at-a-distance (stand-off) capabilities for THz sensing systems. We have made several reflection measurements of metallic and non-metallic targets in our laboratory, and have observed high contrast relative to reflection from skin. In particular, we have taken small quantities of energetic materials such as plastic explosives and a variety of Bacillus spores, and measured them in transmission and in reflection using a broadband pulsed electronic THz reflectometer. The pattern of reflection versus frequency gives rise to signatures that are remarkably specific to the composition of the target, even though the target's morphology and position is varied. Although more work needs to be done to reduce the effects of standing waves through time-gating or attenuators, the possibility of mapping out this contrast for imaging and detection is very attractive.
NASA Astrophysics Data System (ADS)
Jin, Minquan; Delshad, Mojdeh; Dwarakanath, Varadarajan; McKinney, Daene C.; Pope, Gary A.; Sepehrnoori, Kamy; Tilburg, Charles E.; Jackson, Richard E.
1995-05-01
In this paper we present a partitioning interwell tracer test (PITT) technique for the detection, estimation, and remediation performance assessment of the subsurface contaminated by nonaqueous phase liquids (NAPLs). We demonstrate the effectiveness of this technique by examples of experimental and simulation results. The experimental results are from partitioning tracer experiments in columns packed with Ottawa sand. Both the method of moments and inverse modeling techniques for estimating NAPL saturation in the sand packs are demonstrated. In the simulation examples we use UTCHEM, a comprehensive three-dimensional, chemical flood compositional simulator developed at the University of Texas, to simulate a hypothetical two-dimensional aquifer with properties similar to the Borden site contaminated by tetrachloroethylene (PCE), and we show how partitioning interwell tracer tests can be used to estimate the amount of PCE contaminant before remedial action and as the remediation process proceeds. Tracer tests results from different stages of remediation are compared to determine the quantity of PCE removed and the amount remaining. Both the experimental (small-scale) and simulation (large-scale) results demonstrate that PITT can be used as an innovative and effective technique to detect and estimate the amount of residual NAPL and for remediation performance assessment in subsurface formations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, M.; Delshad, M.; Dwarakanath, V.
1995-05-01
In this paper we present a partitioning interwell tracer test (PITT) technique for the detection, estimation, and remediation performance assessment of the subsurface contaminated by nonaqueous phase liquids (NAPLs). We demonstrate the effectiveness of this technique by examples of experimental and simulation results. The experimental results are from partitioning tracer experiments in columns packed with Ottawa sand. Both the method of moments and inverse modeling techniques for estimating NAPL saturation in the sand packs are demonstrated. In the simulation examples we use UTCHEM, a comprehensive three-dimensional, chemical flood compositional simulator developed at the University of Texas, to simulate a hypotheticalmore » two-dimensional aquifer with properties similar to the Borden site contaminated by tetrachloroethylene (PCE), and we show how partitioning interwell tracer tests can be used to estimate the amount of PCE contaminant before remedial action and as the remediation process proceeds. Tracer test results from different stages of remediation are compared to determine the quantity of PCE removed and the amount remaining. Both the experimental (small-scale) and simulation (large-scale) results demonstrate that PITT can be used as an innovative and effective technique to detect and estimate the amount of residual NAPL and for remediation performance assessment in subsurface formations. 43 refs., 10 figs., 1 tab.« less
de Marcellus, Pierre; Bertrand, Marylène; Nuevo, Michel; Westall, Frances; Le Sergeant d'Hendecourt, Louis
2011-11-01
The delivery of extraterrestrial organic materials to primitive Earth from meteorites or micrometeorites has long been postulated to be one of the origins of the prebiotic molecules involved in the subsequent apparition of life. Here, we report on experiments in which vacuum UV photo-irradiation of interstellar/circumstellar ice analogues containing H(2)O, CH(3)OH, and NH(3) led to the production of several molecules of prebiotic interest. These were recovered at room temperature in the semi-refractory, water-soluble residues after evaporation of the ice. In particular, we detected small quantities of hydantoin (2,4-imidazolidinedione), a species suspected to play an important role in the formation of poly- and oligopeptides. In addition, hydantoin is known to form under extraterrestrial, abiotic conditions, since it has been detected, along with various other derivatives, in the soluble part of organic matter of primitive carbonaceous meteorites. This result, together with other related experiments reported recently, points to the potential importance of the photochemistry of interstellar "dirty" ices in the formation of organics in Solar System materials. Such molecules could then have been delivered to the surface of primitive Earth, as well as other telluric (exo-) planets, to help trigger first prebiotic reactions with the capacity to lead to some form of primitive biomolecular activity.
Avula, Bharathi; Chittiboyina, Amar G; Sagi, Satyanarayanaraju; Wang, Yan-Hong; Wang, Mei; Khan, Ikhlas A; Cohen, Pieter A
2016-01-01
Vinpocetine and picamilon are drugs prescribed in many countries to treat a variety of cerebrovascular disorders. In the United States, vinpocetine and picamilon have never been approved by the US Food and Drug Administration, but they are both available for sale directly to consumers as dietary supplements. We designed our study to determine the accuracy of supplement labels with regard to the presence and quantity of vinpocetine and picamilon. A validated ultra-high performance liquid chromatography-photodiode-array method was developed for the quantification of vinpocetine and picamilon. The separation was achieved using a reversed phase (C-18) column, photodiode array detection, and water/acetonitrile as the mobile phase. Vinpocetine and picamilon were detected at concentrations as low as 10 and 50 ng/mL, respectively. The presence of vinpocetine and picamilon was confirmed using reference standards. Twenty-three supplements labelled as containing vinpocetine were available for sale at two large supplement retail chains; 17 contained vinpocetine with quantities ranging from 0.3 to 32 mg per recommended daily serving. No vinpocetine was detected in six of the sampled supplements. The supplement label implied that vinpocetine was a constituent of lesser periwinkle in three of the supplements. Of the 31 picamilon supplements available for sale from a variety of retailers: 30 contained picamilon in quantities ranging from 2.7 to 721.5 mg per recommended daily serving. We found that consumers cannot obtain accurate information from supplement labels regarding the presence or quantity of vinpocetine and picamilon. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Sun, Siao; Barraud, Sylvie; Castebrunet, Hélène; Aubin, Jean-Baptiste; Marmonier, Pierre
2015-11-15
The assessment of urban stormwater quantity and quality is important for evaluating and controlling the impact of the stormwater to natural water and environment. This study mainly addresses long-term evolution of stormwater quantity and quality in a French urban catchment using continuous measured data from 2004 to 2011. Storm event-based data series are obtained (716 rainfall events and 521 runoff events are available) from measured continuous time series. The Mann-Kendall test is applied to these event-based data series for trend detection. A lack of trend is found in rainfall and an increasing trend in runoff is detected. As a result, an increasing trend is present in the runoff coefficient, likely due to growing imperviousness of the catchment caused by urbanization. The event mean concentration of the total suspended solid (TSS) in stormwater does not present a trend, whereas the event load of TSS has an increasing tendency, which is attributed to the increasing event runoff volume. Uncertainty analysis suggests that the major uncertainty in trend detection results lies in uncertainty due to available data. A lack of events due to missing data leads to dramatically increased uncertainty in trend detection results. In contrast, measurement uncertainty in time series data plays a trivial role. The intra-event distribution of TSS is studied based on both M(V) curves and pollutant concentrations of absolute runoff volumes. The trend detection test reveals no significant change in intra-event distributions of TSS in the studied catchment. Copyright © 2015 Elsevier Ltd. All rights reserved.
The Application of Quantity Discounts in Army Procurements (Field Test).
1980-04-01
Work Directive (PWD). d. The amended PWD is forwarded to the Procurement and Production (PP) control where quantity increments and delivery schedules are...counts on 97 Army Stock Fund small purchases (less than $10,000) and received 10 I be * 0p cebe * )~ Cb 111 cost effective discounts on 46 or 47.4% of...discount but the computed annualized cost for the QD increment was larger than the computed annualized cost for the EOQ, this was not a cost effective
Flat connections and nonlocal conserved quantities in irrational conformal field theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halpern, M.B.; Obers, N.A.
1995-03-01
Irrational conformal field theory (ICFT) includes rational conformal field theory as a small subspace, and the affine-Virasoro Ward identities describe the biconformal correlators of ICFT. The Ward identities are reformulated as an equivalent linear partial differential system with flat connections and new nonlocal conserved quantities. As examples of the formulation, the system of flat connections is solved for the coset correlators, the correlators of the affine-Sugawara nests, and the high-level [ital n]-point correlators of ICFT.
NASA Astrophysics Data System (ADS)
Ilgin, Irfan; Yang, I.-Sheng
2014-08-01
We show that for every qubit of quantum information, there is a well-defined notion of "the amount of energy that carries it," because it is a conserved quantity. This generalizes to larger systems and any conserved quantities: the eigenvalue spectrum of conserved charges has to be preserved while transferring quantum information. It is possible to "apparently" violate these conservations by losing a small fraction of information, but that must invoke a specific process which requires a large scale coherence. We discuss its implication regarding the black hole information paradox.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouzigues, H.; Reneaud, J.-M.
1963-01-01
A method and a special apparatus are described which make it possible to detach the insoluble plutonium salt deposits in the extraction chain of an irradiated fuel treatment plant. The process chosen allows the detection, in the extraction batteries or in the highly active chemical engineering equipment, of plutonium quantities of a few grams. After four years operation it has been impossible to detect measurable quantities of plutonium in any part of the extraction chain. The results have been confirmed by visual examinations carried out with a specially constructed endoscope. (auth)
Airborne remote sensing to detect greenbug stress to wheat
USDA-ARS?s Scientific Manuscript database
Vegetation indices calculated from the quantity of reflected electromagnetic radiation have been used to quantify levels of stress to plants. Greenbugs cause stress to wheat plants and therefore multi-spectral remote sensing may be useful for detecting greenbug infested wheat fields. The objective...
Molecular Detection of Campylobacter spp. in California Gull (Larus californicus) Excreta
We examined the prevalence, quantity, and diversity of Campylobacter species in the excreta of 159 California gull samples using PCR and qPCR based detection assays. While Campylobacter prevalence and abundance was relatively high in the gull excreta examined, molecular data ind...
Guidelines for evaluating fish habitat in Wisconsin streams.
Timothy D. Simonson; John Lyons; Paul D. Kanehl
1993-01-01
Describes procedures for evaluating the quality and quantity of habitat for fish in small and medium streams of Wisconsin. Provides detailed guidelines for collecting and analyzing specific quantitative habitat information.
Small-world behaviour in a system of mobile elements
NASA Astrophysics Data System (ADS)
Manrubia, S. C.; Delgado, J.; Luque, B.
2001-03-01
We analyze the propagation of activity in a system of mobile automata. A number ρLd of elements move as random walkers on a lattice of dimension d, while with a small probability p they can jump to any empty site in the system. We show that this system behaves as a Dynamic Small World (DSW) and present analytic and numerical results for several quantities. Our analysis shows that the persistence time T* (equivalent to the persistence size L* of small-world networks) scales as T* ~ (ρp)-τ, with τ = 1/(d + 1).
The Interrelationships of Mathematical Precursors in Kindergarten
Cirino, Paul T.
2011-01-01
This study evaluated the interrelations among cognitive precursors across quantitative, linguistic, and spatial attention domains that have been implicated for math achievement in young children. The dimensionality of the quantity precursors was evaluated in 286 Kindergarteners via latent variable techniques, and the contribution of precursors from each domain was established for small sums addition. Results showed a five factor structure for the quantity precursors with the major distinction between nonsymbolic and symbolic tasks. The overall model demonstrated good fit, and strong predictive power (R2 = 55%) for addition number combinations. Linguistic and spatial attention domains showed indirect relationships with outcomes, with their effects mediated by symbolic quantity measures. These results have implications for the measurement of mathematical precursors, and yield promise for predicting future math performance. PMID:21194711
1992-01-01
except TPH, which was detected at 0.06 mg/l in Monitor Well 01-MW-02. Some metals (arsenic, cadmium , chromium, lead, silver, and zinc ) were detected at...extraction. Trace quantities of some priority pollutant metals were detected in the surface water samples. Arsenic, cadmium , and zinc were detected at...storage tank. TPH was detected in all five groundwater samples. Arsenic, beryllium, cadmium , chromium, copper, lead, nickel, silver, and zinc were also
49 CFR 173.199 - Category B infectious substances.
Code of Federal Regulations, 2010 CFR
2010-10-01
... this section; (ii) Anticoagulants used to stabilize blood or plasma; or (iii) Small quantities of Class... copy or electronic image of these instructions must be retained by the manufacturer and subsequent...
75 FR 6062 - Manufacturer of Controlled Substances Notice of Registration
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-05
... controlled substances listed in schedules I and II: Drug Schedule Marihuana (7360) I Tetrahydrocannabinols (7370) I Cocaine (9041) I The Institute will manufacture small quantities of cocaine and marihuana...
Device for sampling and enriching impurities in hydrogen comprising hydrogen-permeable membrane
Ahmed, Shabbir; Papadias, Dionissios D.; Lee, Sheldon D. H.; Kumar, Romesh
2017-01-31
Provided herein are methods and devices to enrich trace quantities of impurities in gaseous mixtures, such as hydrogen fuel. The methods and devices rely on concentration of impurities so as to allow the detection of the impurities using commonly-available detection methods.
Three faces of node importance in network epidemiology: Exact results for small graphs
NASA Astrophysics Data System (ADS)
Holme, Petter
2017-12-01
We investigate three aspects of the importance of nodes with respect to susceptible-infectious-removed (SIR) disease dynamics: influence maximization (the expected outbreak size given a set of seed nodes), the effect of vaccination (how much deleting nodes would reduce the expected outbreak size), and sentinel surveillance (how early an outbreak could be detected with sensors at a set of nodes). We calculate the exact expressions of these quantities, as functions of the SIR parameters, for all connected graphs of three to seven nodes. We obtain the smallest graphs where the optimal node sets are not overlapping. We find that (i) node separation is more important than centrality for more than one active node, (ii) vaccination and influence maximization are the most different aspects of importance, and (iii) the three aspects are more similar when the infection rate is low.
Ultrasonic characterization of single drops of liquids
Sinha, Dipen N.
1998-01-01
Ultrasonic characterization of single drops of liquids. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities.
A semi-automated, field-portable microscopy platform for clinical diagnostic applications
NASA Astrophysics Data System (ADS)
Jagannadh, Veerendra Kalyan; Srinivasan, Rajesh; Gorthi, Sai Siva
2015-08-01
Clinical microscopy is a versatile diagnostic platform used for diagnosis of a multitude of diseases. In the recent past, many microfluidics based point-of-care diagnostic devices have been developed, which serve as alternatives to microscopy. However, these point-of-care devices are not as multi-functional and versatile as clinical microscopy. With the use of custom designed optics and microfluidics, we have developed a versatile microscopy-based cellular diagnostic platform, which can be used at the point of care. The microscopy platform presented here is capable of detecting infections of very low parasitemia level (in a very small quantity of sample), without the use of any additional computational hardware. Such a cost-effective and portable diagnostic device, would greatly impact the quality of health care available to people living in rural locations of the world. Apart from clinical diagnostics, it's applicability to field research in environmental microbiology has also been outlined.
Product differentiation during continuous-flow thermal gradient PCR.
Crews, Niel; Wittwer, Carl; Palais, Robert; Gale, Bruce
2008-06-01
A continuous-flow PCR microfluidic device was developed in which the target DNA product can be detected and identified during its amplification. This in situ characterization potentially eliminates the requirement for further post-PCR analysis. Multiple small targets have been amplified from human genomic DNA, having sizes of 108, 122, and 134 bp. With a DNA dye in the PCR mixture, the amplification and unique melting behavior of each sample is observed from a single fluorescent image. The melting behavior of the amplifying DNA, which depends on its molecular composition, occurs spatially in the thermal gradient PCR device, and can be observed with an optical resolution of 0.1 degrees C pixel(-1). Since many PCR cycles are within the field of view of the CCD camera, melting analysis can be performed at any cycle that contains a significant quantity of amplicon, thereby eliminating the cycle-selection challenges typically associated with continuous-flow PCR microfluidics.
Miniaturized flow injection analysis system
Folta, J.A.
1997-07-01
A chemical analysis technique known as flow injection analysis is described, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38{times}25{times}3 mm, but can be designed for gas analysis and be substantially smaller in construction. 9 figs.
Follicular penetration of topically applied caffeine via a shampoo formulation.
Otberg, N; Teichmann, A; Rasuljev, U; Sinkgraven, R; Sterry, W; Lademann, J
2007-01-01
Follicular drug delivery is the prerequisite for an effective treatment of androgenetic alopecia or other reasons of premature hair loss. The follicular penetration of caffeine, applied topically in a shampoo formulation for 2 min, was measured with highly sensitive surface ionization in combination with mass spectroscopy, a selective method for the detection of very small quantities of transcutaneously absorbed substances in the blood. An experimental protocol, developed to selectively block the follicular pathway within the test area, was used. Based on this principle, a clear distinction between interfollicular and follicular penetration of topically applied caffeine was feasible. After 2 min, caffeine penetrated via the hair follicles and stratum corneum. It was found that the penetration via hair follicles was faster and higher compared with the interfollicular route and that hair follicles are the only pathway for fast caffeine absorption during the first 20 min after application. Copyright 2007 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Lesiuk, Michał; Moszynski, Robert
2014-12-01
In this paper we consider the calculation of two-center exchange integrals over Slater-type orbitals (STOs). We apply the Neumann expansion of the Coulomb interaction potential and consider calculation of all basic quantities which appear in the resulting expression. Analytical closed-form equations for all auxiliary quantities have already been known but they suffer from large digital erosion when some of the parameters are large or small. We derive two differential equations which are obeyed by the most difficult basic integrals. Taking them as a starting point, useful series expansions for small parameter values or asymptotic expansions for large parameter values are systematically derived. The resulting expansions replace the corresponding analytical expressions when the latter introduce significant cancellations. Additionally, we reconsider numerical integration of some necessary quantities and present a new way to calculate the integrand with a controlled precision. All proposed methods are combined to lead to a general, stable algorithm. We perform extensive numerical tests of the introduced expressions to verify their validity and usefulness. Advances reported here provide methodology to compute two-electron exchange integrals over STOs for a broad range of the nonlinear parameters and large angular momenta.
Haeckel, Rainer; Wosniok, Werner
2010-10-01
The distribution of many quantities in laboratory medicine are considered to be Gaussian if they are symmetric, although, theoretically, a Gaussian distribution is not plausible for quantities that can attain only non-negative values. If a distribution is skewed, further specification of the type is required, which may be difficult to provide. Skewed (non-Gaussian) distributions found in clinical chemistry usually show only moderately large positive skewness (e.g., log-normal- and χ(2) distribution). The degree of skewness depends on the magnitude of the empirical biological variation (CV(e)), as demonstrated using the log-normal distribution. A Gaussian distribution with a small CV(e) (e.g., for plasma sodium) is very similar to a log-normal distribution with the same CV(e). In contrast, a relatively large CV(e) (e.g., plasma aspartate aminotransferase) leads to distinct differences between a Gaussian and a log-normal distribution. If the type of an empirical distribution is unknown, it is proposed that a log-normal distribution be assumed in such cases. This avoids distributional assumptions that are not plausible and does not contradict the observation that distributions with small biological variation look very similar to a Gaussian distribution.
Biotransformation of N-Nitrosodimethylamine by Pseudomonas mendocina KR1▿
Fournier, Diane; Hawari, Jalal; Streger, Sheryl H.; McClay, Kevin; Hatzinger, Paul B.
2006-01-01
N-Nitrosodimethylamine (NDMA) is a potent carcinogen and an emerging contaminant in groundwater and drinking water. The metabolism of NDMA in mammalian cells has been widely studied, but little information is available concerning the microbial transformation of this compound. The objective of this study was to elucidate the pathway(s) of NDMA biotransformation by Pseudomonas mendocina KR1, a strain that possesses toluene-4-monooxygenase (T4MO). P. mendocina KR1 was observed to initially oxidize NDMA to N-nitrodimethylamine (NTDMA), a novel metabolite. The use of 18O2 and H218O revealed that the oxygen added to NDMA to produce NTDMA was derived from atmospheric O2. Experiments performed with a pseudomonad expressing cloned T4MO confirmed that T4MO catalyzes this initial reaction. The NTDMA produced by P. mendocina KR1 did not accumulate, but rather it was metabolized further to produce N-nitromethylamine (88 to 94% recovery) and a trace amount of formaldehyde (HCHO). Small quantities of methanol (CH3OH) were also detected when the strain was incubated with NDMA but not during incubation with either NTDMA or HCHO. The formation of methanol is hypothesized to occur via a second, minor pathway mediated by an initial α-hydroxylation of the nitrosamine. Strain KR1 did not grow on NDMA or mineralize significant quantities of the compound to carbon dioxide, suggesting that the degradation process is cometabolic. PMID:16950909
Chamberlain, Mike; Gräfe, James L; Aslam; Byun, Soo-Hyun; Chettle, David R; Egden, Lesley M; Webber, Colin E; McNeill, Fiona E
2012-03-01
Humans can be exposed to fluorine (F) through their diet, occupation, environment and oral dental care products. Fluorine, at proper dosages, is believed to have positive effects by reducing the incidence of dental caries, but fluorine toxicity can occur when people are exposed to excessive quantities of fluorine. In this paper we present the results of a small pilot in vivo study on 33 participants living in Southwestern Ontario, Canada. The mean age of participants was 45 ± 18 years with a range of 20-87 years. The observed calcium normalized hand-bone-fluorine concentrations in this small pilot study ranged from 1.1 to 8.8 mg F/g Ca. Every person measured in this study had levels of fluorine in bone above the detection limit of the system. The average fluorine concentration in bone was found to be 3.5 ± 0.4 mg F/g Ca. No difference was observed in average concentration for men and women. In addition, a significant correlation (r(2) = 0.55, p < 0.001) was observed between hand-bone-fluorine content and age. The amount of fluorine was found to increase at a rate of 0.084 ± 0.014 mg F/g Ca per year. There was no significant difference observed in this small group of subjects between the accumulation rates in men and women. To the best of our knowledge, this is the first time data from in vivo measurement of fluorine content in humans by neutron activation analysis have been presented. The data determined by this technique were found to be consistent with results from ex vivo studies from other countries. We suggest that the data demonstrate that this low risk non-invasive diagnostic technique will permit the routine assessment of bone-fluorine content with potential application in the study of clinical bone-related diseases. This small study demonstrated that people in Southern Ontario are exposed to fluoride in measureable quantities, and that fluoride can be seen to accumulate in bone with age. However, all volunteers were found to have levels below those expected with clinical fluorosis, and only one older subject was found to have levels comparable with preclinical exposure.
METHOD OF DISSOLVING MASSIVE PLUTONIUM
Facer, J.F.; Lyon, W.L.
1960-06-28
Massive plutonium can be dissolved in a hot mixture of concentrated nitric acid and a small quantity of hydrofluoric acid. A preliminary oxidation with water under superatmospheric pressure at 140 to 150 deg C is advantageous
49 CFR 173.4 - Small quantities for highway and rail.
Code of Federal Regulations, 2010 CFR
2010-10-01
... hazard classes, are not subject to any other requirements of this subchapter when— (1) The maximum... a package containing a Class 7 (radioactive) material. (2) With the exception of temperature sensing...
Regeneration after clear-cutting second-growth northern hardwoods
Robert W. Wilson; Victor S. Jensen
1954-01-01
Regeneration after clear-cutting second-growth northern hardwoods is often unsatisfactory, in both quantity and species composition. A small area on the Bartlett Experimental Forest near Bartlett, N.H., provides a good example.
NASA Astrophysics Data System (ADS)
de Oliveira, Helder C. R.; Mencattini, Arianna; Casti, Paola; Martinelli, Eugenio; di Natale, Corrado; Catani, Juliana H.; de Barros, Nestor; Melo, Carlos F. E.; Gonzaga, Adilson; Vieira, Marcelo A. C.
2018-02-01
This paper proposes a method to reduce the number of false-positives (FP) in a computer-aided detection (CAD) scheme for automated detection of architectural distortion (AD) in digital mammography. AD is a subtle contraction of breast parenchyma that may represent an early sign of breast cancer. Due to its subtlety and variability, AD is more difficult to detect compared to microcalcifications and masses, and is commonly found in retrospective evaluations of false-negative mammograms. Several computer-based systems have been proposed for automated detection of AD in breast images. The usual approach is automatically detect possible sites of AD in a mammographic image (segmentation step) and then use a classifier to eliminate the false-positives and identify the suspicious regions (classification step). This paper focus on the optimization of the segmentation step to reduce the number of FPs that is used as input to the classifier. The proposal is to use statistical measurements to score the segmented regions and then apply a threshold to select a small quantity of regions that should be submitted to the classification step, improving the detection performance of a CAD scheme. We evaluated 12 image features to score and select suspicious regions of 74 clinical Full-Field Digital Mammography (FFDM). All images in this dataset contained at least one region with AD previously marked by an expert radiologist. The results showed that the proposed method can reduce the false positives of the segmentation step of the CAD scheme from 43.4 false positives (FP) per image to 34.5 FP per image, without increasing the number of false negatives.
Making Aircraft Vortices Visible to Radar by Spraying Water into the Wake.
Shariff, Karim
2016-12-01
Aircraft trailing vortices pose a danger to following aircraft during take-off and landing. This necessitates spacing rules, based on aircraft type, to be enforced during approach in IFR (Instrument Flight Regulations) conditions; this can limit airport capacity. To help choose aircraft spacing based on the actual location and strength of the wake, it is proposed that wake vortices can be detected using conventional precipitation and cloud radars. This is enabled by spraying a small quantity water into the wake from near the wing. The vortex strength is revealed by the doppler velocity of the droplets. In the present work, droplet size distributions produced by nozzles used for aerial spraying are considered. Droplet trajectory and evaporation in the flow-field is numerically calculated for a heavy aircraft, followed by an evaluation of radar reflectivity at 6 nautical miles behind the aircraft. Small droplets evaporate away while larger droplets fall out of the wake. In the humid conditions that typically prevail during IFR, a sufficient number of droplets remain in the wake and give good signal-to-noise ratios (SNR). For conditions of average humidity, higher frequency radars combined with spectral processing gives good SNR.
Making Aircraft Vortices Visible to Radar by Spraying Water into the Wake
NASA Technical Reports Server (NTRS)
Shariff, Karim
2016-01-01
Aircraft trailing vortices pose a danger to following aircraft during take-off and landing. This necessitates spacing rules, based on aircraft type, to be enforced during approach in IFR (Instrument Flight Regulations) conditions; this can limit airport capacity. To help choose aircraft spacing based on the actual location and strength of the wake, it is proposed that wake vortices can be detected using conventional precipitation and cloud radars. This is enabled by spraying a small quantity water into the wake from near the wing. The vortex strength is revealed by the doppler velocity of the droplets. In the present work, droplet size distributions produced by nozzles used for aerial spraying are considered. Droplet trajectory and evaporation in the flow-field is numerically calculated for a heavy aircraft, followed by an evaluation of radar reflectivity at 6 nautical miles behind the aircraft. Small droplets evaporate away while larger droplets fall out of the wake. In the humid conditions that typically prevail during IFR, a sufficient number of droplets remain in the wake and give good signal-to-noise ratios (SNR). For conditions of average humidity, higher frequency radars combined with spectral processing gives good SNR.
Making Aircraft Vortices Visible to Radar by Spraying Water into the Wake
Shariff, Karim
2017-01-01
Aircraft trailing vortices pose a danger to following aircraft during take-off and landing. This necessitates spacing rules, based on aircraft type, to be enforced during approach in IFR (Instrument Flight Regulations) conditions; this can limit airport capacity. To help choose aircraft spacing based on the actual location and strength of the wake, it is proposed that wake vortices can be detected using conventional precipitation and cloud radars. This is enabled by spraying a small quantity water into the wake from near the wing. The vortex strength is revealed by the doppler velocity of the droplets. In the present work, droplet size distributions produced by nozzles used for aerial spraying are considered. Droplet trajectory and evaporation in the flow-field is numerically calculated for a heavy aircraft, followed by an evaluation of radar reflectivity at 6 nautical miles behind the aircraft. Small droplets evaporate away while larger droplets fall out of the wake. In the humid conditions that typically prevail during IFR, a sufficient number of droplets remain in the wake and give good signal-to-noise ratios (SNR). For conditions of average humidity, higher frequency radars combined with spectral processing gives good SNR. PMID:28804200
Chemical Conversion of Anhydrous Hydrogen Fluoride for Safe Disposal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blake, Thomas A.; Brauer, Carolyn S.; Bachmann, William J.
A procedure for the safe conversion of a small (~ 1 gram) quantity of anhydrous hydrogen fluoride to calcium fluoride is described. The purpose of the conversion is to put the toxic, corrosive, gaseous compound into a chemical form that is a less toxic solid (calcium fluoride) and easier to dispose of. The hydrogen fluoride, which was contained in a 50 cc metal sample cylinder, was drawn by a small mechanical vacuum pump through an all-metal gas manifold and into a metal trap containing alternating layers of calcium oxide powder and Teflon turnings. The anhydrous hydrogen fluoride reacts with themore » calcium oxide to produce calcium fluoride and water vapor. Because some of the calcium oxide powder was drawn out of the trap and into the vacuum tubing, it was not possible to quantify the amount of anhydrous hydrogen fluoride converted to calcium fluoride. However, it was noted that there was a temperature rise in the trap when the gas was flowing through it, and no HF gas was detected at the vacuum pump exhaust at this time using a colorimetric Dräger tube. The trap was sealed and disposed of as solid chemical waste.« less
Studies on the structures of the Tm, Sj, M1, Can, Sext and Hu blood group antigens.
Dahr, W; Knuppertz, G; Beyreuther, K; Moulds, J J; Moulds, M; Wilkinson, S; Capon, C; Fournet, B; Issitt, P D
1991-08-01
The Glycophorins (GPs = sialoglycoproteins) in erythrocyte membranes from various Black individuals, some of which exhibit the M1, Can, Sj, Tm, Sext and/or Hu antigens, and several Caucasian donors, including pooled fetal red cells, were studied. Using agglutination inhibition assays with GP fractions, GP fragments and chemically modified GPs as well as trypsin treatment of intact red cells, the antigens defined by anti-M1, anti-M+M1, anti-Can and anti-Tm sera were found to be located on the N-terminal tryptic peptide (T2, residues 1-31) of the major GP (GP A = MN sialoglycoprotein). Evidence was obtained that the N-terminal amino-acid residue, NeuNAc and/or (a) different sugar residue(s) are involved in the antigens. Amino-acid sequence and composition analyses excluded an amino-acid exchange within the N-terminal region (residues 1-31) of GP A. Carbohydrate analyses revealed the attachment of GlcNAc residues (up to about five, dependent on the strength of the above-mentioned antigens) to O-glycosidically linked oligosaccharides within the N-terminal portion (residues 1-31) of GP A. As judged from the carbohydrate compositions of peptides, the alteration of the O-glycosidic oligosaccharides is associated with a slight increase of the Gal and Fuc contents and a slight decrease of the NeuNAc level. Analyses of small, secondary cyanogen bromide and V8 proteinase peptides from the N-terminal region of GP A from Blacks, Caucasians and Caucasian fetal cells suggest that the variable attachment of small quantities of GlcNAc (about 0.03 to about 0.2 residues per peptide molecule) accounts, at least in part, for the polymorphisms detected by anti-Can and the original anti-Tm (serum Sheerin). Remarkably, the GlcNAc-containing O-glycosidic oligosaccharides occur only in small quantities, or not all at, within the positions 32-61 of GP A and the glycosylated domains of GP B and GP C.(ABSTRACT TRUNCATED AT 400 WORDS)
Melting and vibrational properties of planetary materials under deep Earth conditions
NASA Astrophysics Data System (ADS)
Jackson, Jennifer
2013-06-01
The large chemical, density, and dynamical contrasts associated with the juxtaposition of a liquid iron-dominant alloy and silicates at Earth's core-mantle boundary (CMB) are associated with a rich range of complex seismological features. For example, seismic heterogeneity at this boundary includes small patches of anomalously low sound velocities, called ultralow-velocity zones. Their small size (5 to 40 km thick) and depth (about 2800 km) present unique challenges for seismic characterization and geochemical interpretation. In this contribution, we will present recent nuclear resonant inelastic x-ray scattering measurements on iron-bearing silicates, oxides, and metals, and their application towards our understanding of Earth's interior. Specifically, we will present measurements on silicates and oxide minerals that are important in Earth's upper and lower mantles, as well as iron to over 1 megabar in pressure. The nuclear resonant inelastic x-ray scattering method provides specific vibrational information, e.g., the phonon density of states, and in combination with compression data permits the determination of sound velocities and other vibrational information under high pressure and high temperature. For example, accurate determination of the sound velocities and density of chemically complex Earth materials is essential for understanding the distribution and behavior of minerals and iron-alloys with depth. The high statistical quality of the data in combination with high energy resolution and a small x-ray focus size permit accurate evaluation of the vibrational-related quantities of iron-bearing Earth materials as a function of pressure, such as the Grüneisen parameter, thermal pressure, sound velocities, and iron isotope fractionation quantities. Finally, we will present a novel method detecting the solid-liquid phase boundary of compressed iron at high temperatures using synchrotron Mössbauer spectroscopy. Our approach is unique because the dynamics of the iron atoms are monitored. This process is described by the Lamb-Mössbauer factor, which is related to the mean-square displacement of the iron atoms. We will discuss the implications of our results as they relate to Earth's core and core-mantle boundary regions.
NASA Astrophysics Data System (ADS)
Farrell, Mikella E.; Holthoff, Ellen L.; Pellegrino, Paul M.
2015-05-01
The requirement to detect hazardous materials (i.e., chemical, biological, and explosive) on a host of materials has led to the development of hazard detection systems. These new technologies and their capabilities could have immediate uses for the US military, national security agencies, and environmental response teams in efforts to keep people secure and safe. In particular, due to the increasing use by terrorists, the detection of common explosives and improvised explosive device (IED) materials have motivated research efforts toward detecting trace (i.e., particle level) quantities on multiple commonly encountered surfaces (e.g., textiles, metals, plastics, natural products, and even people). Non-destructive detection techniques can detect trace quantities of explosive materials; however, it can be challenging in the presence of a complex chemical background. One spectroscopic technique gaining increased attention for detection is Raman. One popular explosive precursor material is ammonium nitrate (AN). The material AN has many agricultural applications, however it can also be used in the fabrication of IEDs or homemade explosives (HMEs). In this paper, known amounts of AN will be deposited using an inkjet printer into several different common material surfaces (e.g., wood, human hair, textiles, metals, plastics). The materials are characterized with microscope images and by collecting Raman spectral data. In this report the detection and identification of AN will be demonstrated.
Arsenic activation neutron detector
Jacobs, E.L.
1980-01-28
A detector of bursts of neutrons from a deuterium-deuteron reaction includes a quantity of arsenic adjacent a gamma detector such as a scintillator and photomultiplier tube. The arsenic is activated by the 2.5-MeV neutrons to release gamma radiation which is detected to give a quantitative representation of detected neutrons.
Arsenic activation neutron detector
Jacobs, Eddy L.
1981-01-01
A detector of bursts of neutrons from a deuterium-deuteron reaction includes a quantity of arsenic adjacent a gamma detector such as a scintillator and photomultiplier tube. The arsenic is activated by the 2.5 Mev neutrons to release gamma radiation which is detected to give a quantitative representation of detected neutrons.
Park, Kyung-Hwa; Greenwood-Quaintance, Kerryl E; Schuetz, Audrey N; Mandrekar, Jayawant N; Patel, Robin
2017-02-01
We developed a rat model of methicillin-resistant Staphylococcus epidermidis (MRSE) foreign body-associated osteomyelitis and used it to compare tedizolid alone and in combination with rifampin against rifampin alone, vancomycin plus rifampin, and vancomycin alone. A clinical strain of MRSE was inoculated into the proximal tibia, and a stainless steel wire with a precolonized MRSE biofilm was implanted. Following a 1-week infection period, 92 rats received either no treatment (n = 17) or 14 days of intraperitoneal tedizolid (n = 15), tedizolid plus rifampin (n = 15), rifampin (n = 15), vancomycin plus rifampin (n = 15), or vancomycin (n = 15). Quantitative bone and wire cultures were performed after treatment completion and also 1 week after infection in a separate group of five rats. The median quantity of staphylococci in bone after the 1-week infection period was 4.89 log 10 CFU/g bone (interquartile range, 3.83 to 5.33 log 10 CFU/g bone); staphylococci were recovered from all associated wires. A median quantity of staphylococci of 3.70 log 10 CFU/g bone was detected in bones of untreated control rats after 3 weeks. Quantities of staphylococci in bones of all treatment groups except the group receiving vancomycin alone (2.78 log 10 CFU/g) were significantly lower than those for untreated controls, with no staphylococci being detected in the groups receiving rifampin monotherapy, tedizolid-plus-rifampin combination therapy, and vancomycin-plus-rifampin combination therapy. Quantities of staphylococci on wires from all treatment groups that included rifampin were significantly lower than those for untreated controls. No resistance to rifampin, tedizolid, or vancomycin was detected. Tedizolid combined with rifampin was active in a rat model of MRSE foreign body-associated osteomyelitis. Copyright © 2017 American Society for Microbiology.
[Construction of rAAV2-GPIIb/IIIa vector and test of its expression and function in vitro].
Wang, Kai; Peng, Jian-Qiang; Chen, Fang-Ping; Wu, Xiao-Bin
2006-04-01
This study was aimed to explore the possibility of rAAV2 vector-mediating gene therapy for Glanzmann' s thrombasthenia. The rAAV2-GPIIb/IIIa vector was constructed. The GPIIb/IIIa gene expression in mammal cell were examined by different methods, such as: detection of mRNA expression in BHK-21 cells after 24 hours of infection (MOI = 1 x 10(5) v.g/cell) was performed by RT-PCR; the relation between MOI and quantity of GPII6/IIIa gene expression was detected by FACS after 48 hours of infection; GPIIb/IIIa protein expression in BHK-21 cells after 48 hours of infection (MOI = 10(5) v x g/cell) was assayed by Western blot, GPIIb/IIIa protein expression on cell surface was detected by immunofluorescence, and the biological function of expressing product was determined by PAC-1 conjunct experiments. The results showed that GPIIb/IIIa gene expression in mRNA level could be detected in BHK-21 cells after 24 hours of infection at MOI = 1 x 10(5) v x g/cell and the GPIIb/IIIa gene expression in protein level could be detected in BHK-21 cells after 48 hours of infection at MOI = 1 x 10(5) v x g/cell. In certain range, quantity of GPIIb/IIIa gene expression increased with MOI, but overdose of MOI decreased quantity of GPIIb/IIIa gene expression. Activated product of GPIIb/IIIa gene expression could combined with PAC-I, and possesed normal biological function. In conclusion, rAAV2 vactor can effectively mediate GPIIb and GPIIIa gene expressing in mammal cells, and the products of these genes exhibit biological function. This result may provide a basis for application of rAAV2 vector in Glanzmann's thrombasthenia gene therapy in furture.
REPRESENTATIVE SAMPLING AND ANALYSIS OF HETEROGENEOUS SOILS
Standard sampling and analysis methods for hazardous substances in contaminated soils currently are available and routinely employed. Standard methods inherently assume a homogeneous soil matrix and contaminant distribution; therefore only small sample quantities typically are p...
1981-03-12
Procurement Work Directive ( PWV ) Procurement Army, CostL to Procure Cost Differential Secondary (PAS) Cost to Buy Economic Order Quantity Procurement...and Assignment of Buyer h. Solicitation Fffort . ) (1) Procurement Planning ( ) ( ) (?) PWV Review and Small Business Coordination ( (3) Determination
Thinning young oak stands for small mine timbers - at a profit
Stanley M. Filip
1949-01-01
Young red oak-white oak stands in the Anthracite Forest Region of Pennsylvania occupy nearly 3/4 million acres of land (fig. 1). At present they are a source of lagging, forepoles, and small props used in the coal mines. Under good cutting practice, a substantial quantity of these mine timbers could be produced by thinning these stands, which would at the same time...
Method of synthesizing and growing copper-indium-diselenide (CuInSe.sub.2) crystals
Ciszek, Theodore F.
1987-01-01
A process for preparing CuInSe.sub.2 crystals includes melting a sufficient quantity of B.sub.2 O.sub.3 along with stoichiometric quantities of Cu, In, and Se in a crucible in a high pressure atmosphere of inert gas to encapsulate the CuInSe.sub.2 melt and confine the Se to the crucible. Additional Se in the range of 1.8 to 2.2 percent over the stoichiometric quantity is preferred to make up for small amounts of Se lost in the process. The crystal is grown by inserting a seed crystal through the B.sub.2 O.sub.3 encapsulate into contact with the CuInSe.sub.2 melt and withdrawing the seed upwardly to grow the crystal thereon from the melt.
Disruption mitigation by injection of small quantities of noble gas in ASDEX Upgrade
NASA Astrophysics Data System (ADS)
Pautasso, G.; Bernert, M.; Dibon, M.; Duval, B.; Dux, R.; Fable, E.; Fuchs, J. C.; Conway, G. D.; Giannone, L.; Gude, A.; Herrmann, A.; Hoelzl, M.; McCarthy, P. J.; Mlynek, A.; Maraschek, M.; Nardon, E.; Papp, G.; Potzel, S.; Rapson, C.; Sieglin, B.; Suttrop, W.; Treutterer, W.; The ASDEX Upgrade Team; The EUROfusion MST1 Team
2017-01-01
The most recent experiments of disruption mitigation by massive gas injection in ASDEX Upgrade have concentrated on small—relatively to the past—quantities of noble gas injected, and on the search for the minimum amount of gas necessary for the mitigation of the thermal loads on the divertor and for a significant reduction of the vertical force during the current quench. A scenario for the generation of a long-lived runaway electron beam has been established; this allows the study of runaway current dissipation by moderate quantities of argon injected. This paper presents these recent results and discusses them in the more general context of physical models and extrapolation, and of the open questions, relevant for the realization of the ITER disruption mitigation system.
Dama, Elisa; Tillhon, Micol; Bertalot, Giovanni; de Santis, Francesca; Troglio, Flavia; Pessina, Simona; Passaro, Antonio; Pece, Salvatore; de Marinis, Filippo; Dell'Orto, Patrizia; Viale, Giuseppe; Spaggiari, Lorenzo; Di Fiore, Pier Paolo; Bianchi, Fabrizio; Barberis, Massimo; Vecchi, Manuela
2016-06-14
Accurate detection of altered anaplastic lymphoma kinase (ALK) expression is critical for the selection of lung cancer patients eligible for ALK-targeted therapies. To overcome intrinsic limitations and discrepancies of currently available companion diagnostics for ALK, we developed a simple, affordable and objective PCR-based predictive model for the quantitative measurement of any ALK fusion as well as wild-type ALK upregulation. This method, optimized for low-quantity/-quality RNA from FFPE samples, combines cDNA pre-amplification with ad hoc generated calibration curves. All the models we derived yielded concordant predictions when applied to a cohort of 51 lung tumors, and correctly identified all 17 ALK FISH-positive and 33 of the 34 ALK FISH-negative samples. The one discrepant case was confirmed as positive by IHC, thus raising the accuracy of our test to 100%. Importantly, our method was accurate when using low amounts of input RNA (10 ng), also in FFPE samples with limited tumor cellularity (5-10%) and in FFPE cytology specimens. Thus, our test is an easily implementable diagnostic tool for the rapid, efficacious and cost-effective screening of ALK status in patients with lung cancer.
Scaling beta-delayed neutron measurements to large detector areas
NASA Astrophysics Data System (ADS)
Sutanto, F.; Nattress, J.; Jovanovic, I.
2017-08-01
We explore the performance of a cargo screening system that consists of two large-sized composite scintillation detectors and a high-energy neutron interrogation source by modeling and simulation. The goal of the system is to measure β-delayed neutron emission from an illicit special nuclear material by use of active interrogation. This task is challenging because the β-delayed neutron yield is small in comparison with the yield of the prompt fission secondary products, β-delayed neutrons are emitted with relatively low energies, and high neutron and gamma backgrounds are typically present. Detectors used to measure delayed neutron emission must exhibit high intrinsic efficiency and cover a large solid angle, which also makes them sensitive to background neutron radiation. We present a case study where we attempt to detect the presence of 5 kg-scale quantities of 235U in a standard air-filled cargo container using 14 MeV neutrons as a probe. We find that by using a total measurement time of ˜11.6 s and a dose equivalent of ˜1.7 mrem, the presence of 235U can be detected with false positive and false negative probabilities that are both no larger than 0.1%.
Choudhary, Tripurari; Rajamanickam, G P; Dendukuri, Dhananjaya
2015-05-07
We present textile weaving as a new technique for the manufacture of miniature electrochemical sensors with significant advantages over current fabrication techniques. Biocompatible silk yarn is used as the material for fabrication instead of plastics and ceramics used in commercial sensors. Silk yarns are coated with conducting inks and reagents before being handloom-woven as electrodes into patches of fabric to create arrays of sensors, which are then laminated, cut and packaged into individual sensors. Unlike the conventionally used screen-printing, which results in wastage of reagents, yarn coating uses only as much reagent and ink as required. Hydrophilic and hydrophobic yarns are used for patterning so that sample flow is restricted to a small area of the sensor. This simple fluidic control is achieved with readily available materials. We have fabricated and validated individual sensors for glucose and hemoglobin and a multiplexed sensor, which can detect both analytes. Chronoamperometry and differential pulse voltammetry (DPV) were used to detect glucose and hemoglobin, respectively. Industrial quantities of these sensors can be fabricated at distributed locations in the developing world using existing skills and manufacturing facilities. We believe such sensors could find applications in the emerging area of wearable sensors for chemical testing.
Nonsense-mediated mRNA decay factor Upf2 exists in both the nucleoplasm and the cytoplasm
TATSUNO, TAKANORI; NAKAMURA, YUKA; MA, SHAOFU; TOMOSUGI, NAOHISA; ISHIGAKI, YASUHITO
2016-01-01
Upf2 protein predominantly localizes to the cytoplasmic fraction, and binds to the exon junction complex (EJC) on spliced mRNA. The present study aimed to determine the cellular site where the interaction between Upf2 and EJC occurs. First, the cell lysate was fractionated into the cytoplasm and nucleoplasm, and western blotting to detect levels of Upf2 protein was performed. Upf2 was clearly detected in the cytoplasm and in the nucleoplasm. Secondly, immunostaining was performed, and the majority of Upf2 was detected in the cytoplasmic perinuclear region; a small quantity of Upf2 was detected in the intranuclear region. RNase treatment of the cells reduced the Upf2 immunostained signal. The immune-purified fractions containing nuclear and cytoplasmic Upf2 also contained one of the EJC core factors, RBM8A. These results implied the existence of Upf2 in the nucleoplasm and the cytoplasm, and it appeared to be involved in the construction of the mRNA complex. In order to verify the construction of Upf2-binding EJC in the nucleoplasm, an in situ proximity ligation assay was performed with anti-Upf2 and anti-RBM8A antibodies. These results demonstrated that their interaction occurred not only in the cytoplasmic region, but also in the intranuclear region. Taken together, these results suggested that Upf2 combines with EJC in both the cytoplasmic and the intranuclear fractions, and that it is involved in mRNA metabolism in human cells. PMID:27221324
NASA Technical Reports Server (NTRS)
Petkov, Mihail P.; Jones, Steven M.
2010-01-01
The Ps-aerogel system [Ps is positronium (an electron-positron-hydrogen-like atom)] has been evaluated and optimized as a potential tool for planetary exploration missions. Different configurations of use were assessed, and the results provide a quantitative measure of the expected performance. The aerogel density is first optimized to attain maximum production of Ps that reaches the pores of the aerogel. This has been accomplished, and the optimum aerogel density is .70 mg/cm3. The aerogel is used as a concentrator for target volatile moieties, which accumulate in its open porosity over an extended period of time. For the detection of the accumulated materials, the use of Ps as a probe for the environment at the pore surface, has been proposed. This concept is based on two steps: (1) using aerogel to produce Ps and (2) using the propensity of Ps to interact differently with organic and inorganic matter. The active area of such a detector will comprise aerogel with a certain density, specific surface area, and gas permeability optimized for Ps production and gas diffusion and adsorption. The aerogel is a natural adsorber of organic molecules, which adhere to its internal surface, where their presence is detected by the Ps probe. Initial estimates indicate that, e.g., trace organic molecules in the Martian atmosphere, can be detected at the ppm level, which rivals current methods having significantly higher complexity, volume, mass, and power consumption (e.g. Raman, IR).
Measurement of surface water runoff from plots of two different sizes
NASA Astrophysics Data System (ADS)
Joel, Abraham; Messing, Ingmar; Seguel, Oscar; Casanova, Manuel
2002-05-01
Intensities and amounts of water infiltration and runoff on sloping land are governed by the rainfall pattern and soil hydraulic conductivity, as well as by the microtopography and soil surface conditions. These components are closely interrelated and occur simultaneously, and their particular contribution may change during a rainfall event, or their effects may vary at different field scales. The scale effect on the process of infiltration/runoff was studied under natural field and rainfall conditions for two plot sizes: small plots of 0·25 m2 and large plots of 50 m2. The measurements were carried out in the central region of Chile in a piedmont most recently used as natural pastureland. Three blocks, each having one large plot and five small plots, were established. Cumulative rainfall and runoff quantities were sampled every 5 min. Significant variations in runoff responses to rainfall rates were found for the two plot sizes. On average, large plots yielded only 40% of runoff quantities produced on small plots per unit area. This difference between plot sizes was observed even during periods of continuous runoff.
NW-MILO Acoustic Data Collection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matzner, Shari; Myers, Joshua R.; Maxwell, Adam R.
2010-02-17
There is an enduring requirement to improve our ability to detect potential threats and discriminate these from the legitimate commercial and recreational activity ongoing in the nearshore/littoral portion of the maritime domain. The Northwest Maritime Information and Littoral Operations (NW-MILO) Program at PNNL’s Coastal Security Institute in Sequim, Washington is establishing a methodology to detect and classify these threats - in part through developing a better understanding of acoustic signatures in a near-shore environment. The purpose of the acoustic data collection described here is to investigate the acoustic signatures of small vessels. The data is being recorded continuously, 24 hoursmore » a day, along with radar track data and imagery. The recording began in August 2008, and to date the data contains tens of thousands of signals from small vessels recorded in a variety of environmental conditions. The quantity and variety of this data collection, with the supporting imagery and radar track data, makes it particularly useful for the development of robust acoustic signature models and advanced algorithms for signal classification and information extraction. The underwater acoustic sensing system is part of a multi-modal sensing system that is operating near the mouth of Sequim Bay. Sequim Bay opens onto the Straight of Juan de Fuca, which contains part of the border between the U.S. and Canada. Table 1 lists the specific components used for the NW-MILO system. The acoustic sensor is a hydrophone permanently deployed at a mean depth of about 3 meters. In addition to a hydrophone, the other sensors in the system are a marine radar, an electro-optical (EO) camera and an infra-red (IR) camera. The radar is integrated with a vessel tracking system (VTS) that provides position, speed and heading information. The data from all the sensors is recorded and saved to a central server. The data has been validated in terms of its usability for characterizing the signatures of small vessels. The sampling rate of 8 kHz and low pass filtering to 2 kHz results in an alias-free signal in the frequency band that is appropriate for small vessels. Calibration was performed using a Lubell underwater speaker so that the raw data signal levels can be converted to sound pressure. Background noise is present due to a nearby pump and as a result of tidal currents. More study is needed to fully characterize the noise, but it does not pose an obstacle to using the acoustic data for the purposes of vessel detection and signature analysis. The detection range for a small vessel was estimated using the calibrated voltage response of the system and a cylindrical spreading model for transmission loss. The sound pressure of a typical vessel with an outboard motor was found to be around 140 dB mPa, and could theoretically be detected from 10 km away. In practical terms, a small vessel could reliably be detected from 3 - 5 km away. The data is archived in netCDF files, a standard scientific file format that is "self describing". This means that each data file contains the metadata - timestamps, units, origin, etc. - needed to make the data meaningful and portable. Other file formats, such as XML, are also supported. A visualization tool has been developed to view the acoustic data in the form of spectrograms, along with the coincident radar track data and camera images.« less
Microsystem strategies for sample preparation in biological detection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, Conrad D.; Galambos, Paul C.; Bennett, Dawn Jonita
2005-03-01
The objective of this LDRD was to develop microdevice strategies for dealing with samples to be examined in biological detection systems. This includes three sub-components: namely, microdevice fabrication, sample delivery to the microdevice, and sample processing within the microdevice. The first component of this work focused on utilizing Sandia's surface micromachining technology to fabricate small volume (nanoliter) fluidic systems for processing small quantities of biological samples. The next component was to develop interfaces for the surface-micromachined silicon devices. We partnered with Micronics, a commercial company, to produce fluidic manifolds for sample delivery to our silicon devices. Pressure testing was completedmore » to examine the strength of the bond between the pressure-sensitive adhesive layer and the silicon chip. We are also pursuing several other methods, both in house and external, to develop polymer-based fluidic manifolds for packaging silicon-based microfluidic devices. The second component, sample processing, is divided into two sub-tasks: cell collection and cell lysis. Cell collection was achieved using dielectrophoresis, which employs AC fields to collect cells at energized microelectrodes, while rejecting non-cellular particles. Both live and dead Staph. aureus bacteria have been collected using RF frequency dielectrophoresis. Bacteria have been separated from polystyrene microspheres using frequency-shifting dielectrophoresis. Computational modeling was performed to optimize device separation performance, and to predict particle response to the dielectrophoretic traps. Cell lysis is continuing to be pursued using microactuators to mechanically disrupt cell membranes. Novel thermal actuators, which can generate larger forces than previously tested electrostatic actuators, have been incorporated with and tested with cell lysis devices. Significant cell membrane distortion has been observed, but more experiments need to be conducted to determine the effects of the observed distortion on membrane integrity and cell viability. Finally, we are using a commercial PCR DNA amplification system to determine the limits of detectable sample size, and to examine the amplification of DNA bound to microspheres. Our objective is to use microspheres as capture-and-carry chaperones for small molecules such as DNA and proteins, enabling the capture and concentration of the small molecules using dielectrophoresis. Current tests demonstrated amplification of DNA bound to micron-sized polystyrene microspheres using 20-50 microliter volume size reactions.« less
Estimating air chemical emissions from research activities using stack measurement data.
Ballinger, Marcel Y; Duchsherer, Cheryl J; Woodruff, Rodger K; Larson, Timothy V
2013-03-01
Current methods of estimating air emissions from research and development (R&D) activities use a wide range of release fractions or emission factors with bases ranging from empirical to semi-empirical. Although considered conservative, the uncertainties and confidence levels of the existing methods have not been reported. Chemical emissions were estimated from sampling data taken from four research facilities over 10 years. The approach was to use a Monte Carlo technique to create distributions of annual emission estimates for target compounds detected in source test samples. Distributions were created for each year and building sampled for compounds with sufficient detection frequency to qualify for the analysis. The results using the Monte Carlo technique without applying a filter to remove negative emission values showed almost all distributions spanning zero, and 40% of the distributions having a negative mean. This indicates that emissions are so low as to be indistinguishable from building background. Application of a filter to allow only positive values in the distribution provided a more realistic value for emissions and increased the distribution mean by an average of 16%. Release fractions were calculated by dividing the emission estimates by a building chemical inventory quantity. Two variations were used for this quantity: chemical usage, and chemical usage plus one-half standing inventory. Filters were applied so that only release fraction values from zero to one were included in the resulting distributions. Release fractions had a wide range among chemicals and among data sets for different buildings and/or years for a given chemical. Regressions of release fractions to molecular weight and vapor pressure showed weak correlations. Similarly, regressions of mean emissions to chemical usage, chemical inventory, molecular weight, and vapor pressure also gave weak correlations. These results highlight the difficulties in estimating emissions from R&D facilities using chemical inventory data. Air emissions from research operations are difficult to estimate because of the changing nature of research processes and the small quantity and wide variety of chemicals used. Analysis of stack measurements taken over multiple facilities and a 10-year period using a Monte Carlo technique provided a method to quantify the low emissions and to estimate release fractions based on chemical inventories. The variation in release fractions did not correlate well with factors investigated, confirming the complexities in estimating R&D emissions.
In vitro detection and quantification of botulinum neurotoxin type E activity in avian blood
Piazza, T.M.; Blehert, D.S.; Dunning, F.M.; Berlowski-Zier, B. M.; Zeytin, F.N.; Samuel, M.D.; Tucker, W.C.
2011-01-01
Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by F??rster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity. ?? 2011, American Society for Microbiology.
In vitro detection and quantification of botulinum neurotoxin type E activity in avian blood
Piazza, Timothy M.; Blehert, David S.; Dunning, F. Mark; Berlowski-Zier, Brenda M.; Zeytin, Fusun N.; Samuel, Michael D.; Tucker, Ward C.
2011-01-01
Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by Förster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity.
In Vitro Detection and Quantification of Botulinum Neurotoxin Type E Activity in Avian Blood▿
Piazza, Timothy M.; Blehert, David S.; Dunning, F. Mark; Berlowski-Zier, Brenda M.; Zeytin, Füsûn N.; Samuel, Michael D.; Tucker, Ward C.
2011-01-01
Botulinum neurotoxin serotype E (BoNT/E) outbreaks in the Great Lakes region cause large annual avian mortality events, with an estimated 17,000 bird deaths reported in 2007 alone. During an outbreak investigation, blood collected from bird carcasses is tested for the presence of BoNT/E using the mouse lethality assay. While sensitive, this method is labor-intensive and low throughput and can take up to 7 days to complete. We developed a rapid and sensitive in vitro assay, the BoTest Matrix E assay, that combines immunoprecipitation with high-affinity endopeptidase activity detection by Förster resonance energy transfer (FRET) to rapidly quantify BoNT/E activity in avian blood with detection limits comparable to those of the mouse lethality assay. On the basis of the analysis of archived blood samples (n = 87) collected from bird carcasses during avian mortality investigations, BoTest Matrix E detected picomolar quantities of BoNT/E following a 2-h incubation and femtomolar quantities of BoNT/E following extended incubation (24 h) with 100% diagnostic specificity and 91% diagnostic sensitivity. PMID:21908624
21 CFR 524.1880 - Prednisolone-neomycin sulfate ophthalmic ointment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of cats and dogs, such as those associated with allergic reactions or gross irritants. A small quantity of the ointment should be expressed into the conjunctival sac four times a day for 7 days. After 7...
21 CFR 524.1880 - Prednisolone-neomycin sulfate ophthalmic ointment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... of cats and dogs, such as those associated with allergic reactions or gross irritants. A small quantity of the ointment should be expressed into the conjunctival sac four times a day for 7 days. After 7...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste Disposal Units...
General Permits for Ocean Dumping
General permits are issued by EPA for the ocean dumping of certain materials that will have a minimal adverse environmental impact and are generally disposed of in small quantities. Information includes examples and ocean disposal sites for general permits
Oxygen carrier for gas chromatographic analysis of inert gases in propellants
NASA Technical Reports Server (NTRS)
Cannon, W. A.
1972-01-01
Gas chromatographic determination of small quantities of inert gases in reactive propellants is discussed. Operating conditions used for specific analyses of helium in diborane and nitrogen in oxygen difluoride are presented in tabular form.
49 CFR 173.4 - Small quantities for highway and rail.
Code of Federal Regulations, 2013 CFR
2013-10-01
... (radioactive) material. (v) Thirty (30) mL water capacity (1.8 cubic inches) for authorized Division 2.2....2 mm (0.008 inch), or earthenware, glass, or metal; (3) Each inner receptacle with a removable...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste Disposal Units...
Letter re: Bio - Lab, Plants 2 and 4, Conyers, Rockdale County
September 24, 1999 letter to Jeffrey T. Pallas from Jennifer R. Kaduck enclosing information about conditionally exempt small quantity generator requirements for Bio - Lab Plants 2 and 4 in Conyers, Rockdale County, Georgia.
ERIC Educational Resources Information Center
Landis, Arthur M.; Davies, Malonne I.; Landis, Linda
2009-01-01
Cleaning erasers are used to support methanol-fueled flame tests. This safe demonstration technique requires only small quantities of materials, provides clean colors for up to 45 seconds, and can be used in the classroom or the auditorium. (Contains 1 note.)
What Dominates the Coronal Emission Spectrum During the Cycle of Impulsive Heating and Cooling?
NASA Technical Reports Server (NTRS)
Bradshaw, Stephen J.; Klimchuk, James A.
2011-01-01
The smoking gun of small-scale, impulsive events heating the solar corona is expected to be the presence of a hot ( > 5 MK) plasma component. Evidence for this has been scarce, but has gradually begun to accumulate due to recent studies designed to constrain the high temperature part of the emission measure distribution. However, the detected hot component is often weaker than models predict and this is due in part to the common modeling assumption that the ionization balance remains in equilibrium. The launch of the latest generation of space-based observing instrumentation aboard Hinode and the Solar Dynamics Observatory (SDO) has brought the matter of the ionization state of the plasma firmly to the forefront. It is timely to consider exactly what emission current instruments would detect when observing a corona heated impulsively on small-scales by nanoflares. Only after we understand the full effects of nonequilibrium ionization can we draw meaningful conclusions about the plasma that is (or is not) present. We have therefore performed a series of hydrodynamic simulations for a variety of different nanoflare properties and initial conditions. Our study has led to several key conclusions. 1. Deviations from equilibrium are greatest for short-duration nanoflares at low initial coronal densities. 2. Hot emission lines are the most affected and are suppressed sometimes to the point of being invisible. 3. The emission detected in all of the SDO-AIA channels is generally dominated by warm, over-dense, cooling plasma. 4. It is difficult not to create coronal loops that emit strongly at 1.5 MK and in the range 2 to 5 MK, which are the most commonly observed kind, for a broad range of nanoflare scenarios. 5. The Fe XV (284.16 ) emission in most of our models is about 10 times brighter than the Ca XVII (192.82 ) emission, consistent with observations. Our overarching conclusion is that small-scale, impulsive heating inducing a nonequilibrium ionization state leads to predictions for observable quantities that are entirely consistent with what is actually observed.
Analysis of the impact of safeguards criteria
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mullen, M.F.; Reardon, P.T.
As part of the US Program of Technical Assistance to IAEA Safeguards, the Pacific Northwest Laboratory (PNL) was asked to assist in developing and demonstrating a model for assessing the impact of setting criteria for the application of IAEA safeguards. This report presents the results of PNL's work on the task. The report is in three parts. The first explains the technical approach and methodology. The second contains an example application of the methodology. The third presents the conclusions of the study. PNL used the model and computer programs developed as part of Task C.5 (Estimation of Inspection Efforts) ofmore » the Program of Technical Assistance. The example application of the methodology involves low-enriched uranium conversion and fuel fabrication facilities. The effects of variations in seven parameters are considered: false alarm probability, goal probability of detection, detection goal quantity, the plant operator's measurement capability, the inspector's variables measurement capability, the inspector's attributes measurement capability, and annual plant throughput. Among the key results and conclusions of the analysis are the following: the variables with the greatest impact on the probability of detection are the inspector's measurement capability, the goal quantity, and the throughput; the variables with the greatest impact on inspection costs are the throughput, the goal quantity, and the goal probability of detection; there are important interactions between variables. That is, the effects of a given variable often depends on the level or value of some other variable. With the methodology used in this study, these interactions can be quantitatively analyzed; reasonably good approximate prediction equations can be developed using the methodology described here.« less
Optimizing detector geometry for trace element mapping by X-ray fluorescence.
Sun, Yue; Gleber, Sophie-Charlotte; Jacobsen, Chris; Kirz, Janos; Vogt, Stefan
2015-05-01
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples. Copyright © 2015. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yue; Gleber, Sophie-Charlotte; Jacobsen, Chris
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersivemore » detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.« less
Optimizing detector geometry for trace element mapping by X-ray fluorescence
Sun, Yue; Gleber, Sophie-Charlotte; Jacobsen, Chris; Kirz, Janos; Vogt, Stefan
2016-01-01
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples. PMID:25600825
Optimizing detector geometry for trace element mapping by X-ray fluorescence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yue; Gleber, Sophie-Charlotte; Jacobsen, Chris
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersivemore » detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.« less
OPERATING THE WAND AND HERCULES PROTOTYPE SYSTEMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
K. GRUETZMACHER; ET AL
2001-01-01
Two prototype systems for low-density Green is Clean (GIC) waste at Los Alamos National Laboratory (LANL) have been in operation for three years at the Solid Waste Operation's (SWOs) non-destructive assay (NDA) building. The Waste Assay for Nonradioactive Disposal (WAND) and the High Efficiency Radiation Counters for Ultimate Low Emission Sensitivity (HERCULES) are used to verify the waste generator's acceptable knowledge (AK) that low-density waste is nonradioactive. GIC waste includes all non-regulated waste generated in radiological controlled areas (RCAs) that has been actively segregated as ''clean'' (i.e., nonradioactive) through the use of waste generator AK. GIC waste that is verifiedmore » clean can be disposed of at the Los Alamos County Landfill. It is estimated that 50-90% of the low-density room trash from RCAs at LANL might be free of contamination. To date, with pilot programs at five facilities at LANL, 3000 cubic feet of GIC waste has been verified clean by these two prototype systems. Both the WAND and HERCULES systems are highly sensitive measurement systems optimized to detect very small quantities of common LANL radionuclides. Both of the systems use a set of phoswich scintillation detectors in close proximity to the waste, which have the capability of detecting plutonium-239 concentrations below 3 pCi per gram of low density waste. Both systems detect low-energy x-rays and a broad range of gamma rays (10-2000 keV), while the WAND system also detects high energy beta particles (>100 keV). The WAND system consists of a bank of six shielded detectors which screen low density shredded waste or stacked sheets of paper moving under the detectors in a twelve inch swath on a conveyor belt. The WAND system was developed and tested at the Los Alamos Plutonium Facility in conjunction with instrument system designers from the Los Alamos Safeguards Science and Technology group. The HERCULES system consists of a bank of three shielded detectors which screen low-density waste in two cubic foot cardboard boxes or in bags sitting on a turntable. Waste that does not pass the verification process can be examined within the facility to determine the type and quantity of the contamination and its origin within a waste container. The paper discusses lessons learned that have helped generators improve their AK segregation.« less
Rodríguez-Borjabad, Cèlia; Ibarretxe, Daiana; Girona, Josefa; Ferré, Raimon; Feliu, Albert; Amigó, Núria; Guijarro, Eugenio; Masana, Luis; Plana, Núria
2018-03-01
Familial hypercholesterolaemia (FH) is underdiagnosed in children. In addition to lipid concentrations, lipoprotein particle quantity and quality could influence cardiovascular risk. We aimed to perform a comprehensive plasma lipid study, including lipoprotein particle number and size assessment by two-dimensional nuclear magnetic resonance (2D-1H-NMR), in children with FH compared to non-affected children and to evaluate the clinical value of these factors as subclinical atherosclerosis biomarkers. One hundred eighty-three children participating in the broad "Hypercholesterolemia Early Detection Programme" (Decopin Project) were recruited. They were categorized as FH, if they had either a positive genetic test or clinical certainty, or as control children (CCh). Medical history, anthropometry and clinical variables were recorded. Standard biochemical measurements were performed. The lipoprotein profile was studied by 2D-1H-NMR. Carotid intima-media thickness (cIMT) was assessed by sonography in 177 children. FH children had a significant 36% increase in LDL particles. The small LDL fraction was increased by 33% compared to CCh. The relative relationship between large, medium and small LDL and the mean LDL particle size was similar between FH children and CCh. The total and small LDL particle numbers were directly associated with and contributed to the determination of the mean cIMT according to bivariate and multivariate analyses in FH children. The higher cholesterol levels of FH children are due to an overall increased number of all LDL particle subclasses, including a notable 33% increase in small LDL. Total and small LDL particle number shows a good correlation with cIMT in FH children. Copyright © 2018 Elsevier B.V. All rights reserved.
Development of a Calibration Strip for Immunochromatographic Assay Detection Systems.
Gao, Yue-Ming; Wei, Jian-Chong; Mak, Peng-Un; Vai, Mang-I; Du, Min; Pun, Sio-Hang
2016-06-29
With many benefits and applications, immunochromatographic (ICG) assay detection systems have been reported on a great deal. However, the existing research mainly focuses on increasing the dynamic detection range or application fields. Calibration of the detection system, which has a great influence on the detection accuracy, has not been addressed properly. In this context, this work develops a calibration strip for ICG assay photoelectric detection systems. An image of the test strip is captured by an image acquisition device, followed by performing a fuzzy c-means (FCM) clustering algorithm and maximin-distance algorithm for image segmentation. Additionally, experiments are conducted to find the best characteristic quantity. By analyzing the linear coefficient, an average value of hue (H) at 14 min is chosen as the characteristic quantity and the empirical formula between H and optical density (OD) value is established. Therefore, H, saturation (S), and value (V) are calculated by a number of selected OD values. Then, H, S, and V values are transferred to the RGB color space and a high-resolution printer is used to print the strip images on cellulose nitrate membranes. Finally, verification of the printed calibration strips is conducted by analyzing the linear correlation between OD and the spectral reflectance, which shows a good linear correlation (R² = 98.78%).
Zhou, Ying; Wang, Haijun; Zhang, Han; Chai, Yaqin; Yuan, Ruo
2018-03-06
The DNA nanocrane with functionalized manipulator and fixed-size base offered a programmable approach to modulate the luminous efficiency of copper nanoclusters (Cu NCs) for achieving remarkable electrochemiluminescence (ECL) enhancement, further the Cu NCs as signal label was constructed in biosensor for ultrasensitive detection of microRNA-155. Herein, the DNA nanocrane was first constructed by combining binding-induced DNA assembly as manipulator and tetrahedral DNA nanostructure (TDN) as base, which harnessed a small quantity of specific target (microRNA (miRNA)-155) binding to trigger assembly of separate DNA components for producing numerous AT-rich double-stranded DNA (dsDNA) on the vertex of TDN. Upon the incubation of Cu 2+ on the AT-rich dsDNA, each DNA-stabilized Cu NCs probe could be in situ electrochemically generated on an individual TDN owing to the A-Cu 2+ -T bond. Thus, the generation of Cu NCs was highly regulated with AT-rich dsDNA as the template, and its lateral distance was tuned by the TDN size, which were two key factors to influence the luminous efficiency of Cu NCs. By coordinate modulation, the detection limit of the ultrasensitive biosensor for miRNA-155 down to 36 aM and the programmable modulation strategy paved the way for comprehensive applications of DNA nanomachines and metal nanoclusters in biosensing and clinical diagnosis.
[Relationship between FoxO1 Expression and Wound Age during Skin Incised Wound Healing].
Chen, Y; Ji, X Y; Fan, Y Y; Yu, L S
2018-02-01
To investigate FoxO1 expression and its time-dependent changes during the skin incised wound healing. After the establishment of the skin incised wound model in mice, the FoxO1 expression of skin in different time periods was detected by immunohistochemistry and Western blotting. Immunohistochemistry staining showed that FoxO1 was weakly expressed in a few fibroblasts of epidermis, hair follicles, sebaceous glands, vessel endothelium and dermis in the control group. The FoxO1 expression was enhanced in the epidermis and skin appendages around the wound during 6-12 h after injury, which could be detected in the infiltrating neutrophils and a small number of monocytes. FoxO1 was mainly expressed in monocytes during 1-3 d after injury, and in neovascular endothelial cells and fibroblasts during 5-10 d. On the 14th day after injury, the FoxO1 expression still could be detected in a few fibroblasts. The Western blotting results showed that the FoxO1 expression quantity of the tissue samples in injury group was higher than in control group. The FoxO1 expression peaked at 12 h and 7 d after injury. FoxO1 is time-dependently expressed in skin wound healing, which can be a useful marker for wound age determination. Copyright© by the Editorial Department of Journal of Forensic Medicine.
Holmes, Tyson H; He, Xiao-Song
2016-10-01
Small, wide data sets are commonplace in human immunophenotyping research. As defined here, a small, wide data set is constructed by sampling a small to modest quantity n,1
Holmes, Tyson H.; He, Xiao-Song
2016-01-01
Small, wide data sets are commonplace in human immunophenotyping research. As defined here, a small, wide data set is constructed by sampling a small to modest quantity n, 1 < n < 50, of human participants for the purpose of estimating many parameters p, such that n < p < 1,000. We offer a set of prescriptions that are designed to facilitate low-variance (i.e. stable), low-bias, interpretive regression modeling of small, wide data sets. These prescriptions are distinctive in their especially heavy emphasis on minimizing use of out-of-sample information for conducting statistical inference. That allows the working immunologist to proceed without being encumbered by imposed and often untestable statistical assumptions. Problems of unmeasured confounders, confidence-interval coverage, feature selection, and shrinkage/denoising are defined clearly and treated in detail. We propose an extension of an existing nonparametric technique for improved small-sample confidence-interval tail coverage from the univariate case (single immune feature) to the multivariate (many, possibly correlated immune features). An important role for derived features in the immunological interpretation of regression analyses is stressed. Areas of further research are discussed. Presented principles and methods are illustrated through application to a small, wide data set of adults spanning a wide range in ages and multiple immunophenotypes that were assayed before and after immunization with inactivated influenza vaccine (IIV). Our regression modeling prescriptions identify some potentially important topics for future immunological research. 1) Immunologists may wish to distinguish age-related differences in immune features from changes in immune features caused by aging. 2) A form of the bootstrap that employs linear extrapolation may prove to be an invaluable analytic tool because it allows the working immunologist to obtain accurate estimates of the stability of immune parameter estimates with a bare minimum of imposed assumptions. 3) Liberal inclusion of immune features in phenotyping panels can facilitate accurate separation of biological signal of interest from noise. In addition, through a combination of denoising and potentially improved confidence interval coverage, we identify some candidate immune correlates (frequency of cell subset and concentration of cytokine) with B cell response as measured by quantity of IIV-specific IgA antibody-secreting cells and quantity of IIV-specific IgG antibody-secreting cells. PMID:27196789
How to leverage a bad inventory situation.
Horsfall, G A
1998-11-01
Small manufacturing companies have a hard time taking advantage of the price breaks that result from large purchase orders. Besides the greater amount of money involved, purchasing large quantities of items demands additional space for storing the items. This article describes a company that created separate inventory management and finance company to provide inventory management services to itself and to market these services to other small companies in its area.
Eran Hood; Michael N. Gooseff; Sherri L. Johnson
2006-01-01
The hydrologic and biogeochemical responses of forested watersheds to inputs of rainfall and snowmelt can be an indicator of internal watershed function. In this study, we assess how the quantity and quality, both chemical and spectroscopic, of stream water DOC changes in response to a 6-day storm event during the wet season of 2003 in three small (2...
Opto-Acoustic Telephone Study.
1983-01-01
teristics of tie’use:, the response of the TALK acutciertoncusbtwnthlgtadechnism cslf e flat acoss the oihe band a small quantity of suspended carbonized ... carbonized fiber in which sound is .generated by the local gas/fiber expansion and contraction. Sound is coupled from the small absorptive chamber to...matrix of carbonized cotton fibers suspended in air. This combination may be regarded as a .pseudo gas." To model the photo acoustic U effect in the
Zwertvaegher, Ingrid Ka; Van Daele, Inge; Verheesen, Peter; Peferoen, Marnix; Nuyttens, David
2017-01-01
Rainfall greatly affects the retention of foliar-applied agroformulations. Improving their resistance to wash-off is therefore of great importance in spray applications. When developing such formulations, small-scale laboratory assays are generally required. A set-up for retention studies using only small amounts of agroformulations (<0.5 L) was developed. The set-up consists of a spray device and a rainfall simulator. The effect of rain quantity (1, 3, 6 mm) on the spray retention of agroformulations was evaluated using this set-up. The data showed that uniform and repeatable spraying was achieved with the small-scale spray device (coefficient of variation 23.4%) on potato pot plants (Solanum tuberosum L.). Rain quantity significantly affected the spray retention. Approximately 40% of the initial deposition was lost after 1 mm of rain at an intensity of 25 mm h -1 . Additional losses decreased with increasing volumes of rain (65 and 80% loss after 3 and 6 mm of rain respectively). Future studies could implement the set-up to evaluate the effect of different rainfall characteristics and formulations on spray retention in order to improve the rainfastness of agroformulations. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Horn, Patricia; Schlichting, André; Baum, Christel; Hammesfahr, Ute; Thiele-Bruhn, Sören; Leinweber, Peter; Broer, Inge
2017-02-10
We introduce an easy, fast and effective method to analyze the influence of genetically modified (GM) plants on soil and model organisms in the laboratory to substitute laborious and time consuming field trials. For the studies described here we focused on two GM plants of the so-called 3rd generation: GM plants producing pharmaceuticals (PMP) and plant made industrials (PMI). Cyanophycin synthetase (cphA) was chosen as model for PMI and Choleratoxin B (CTB) as model for PMP. The model genes are expressed in transgenic roots of composite Vicia hirsuta plants grown in petri dishes for semi-sterile growth or small containers filled with non-sterile soil. No significant influence of the model gene expression on root induction, growth, biomass, interaction with symbionts such as rhizobia (number, size and functionality of nodules, selection of nodulating strains) or arbuscular mycorrhizal fungi could be detected. In vitro, but not in situ under field conditions, structural diversity of the bulk soil microbial community between transgenic and non-transgenic cultivars was determined by PLFA pattern-derived ratios of bacteria: fungi and of gram + : gram - bacteria. Significant differences in PLFA ratios were associated with dissimilarities in the quantity and molecular composition of rhizodeposits as revealed by Py-FIMS analyses. Contrary to field trials, where small effects based on the transgene expression might be hidden by the immense influence of various environmental factors, our in vitro system can detect even minor effects and correlates them to transgene expression with less space, time and labour. Copyright © 2016 Elsevier B.V. All rights reserved.
Automated Propulsion Data Screening demonstration system
NASA Technical Reports Server (NTRS)
Hoyt, W. Andes; Choate, Timothy D.; Whitehead, Bruce A.
1995-01-01
A fully-instrumented firing of a propulsion system typically generates a very large quantity of data. In the case of the Space Shuttle Main Engine (SSME), data analysis from ground tests and flights is currently a labor-intensive process. Human experts spend a great deal of time examining the large volume of sensor data generated by each engine firing. These experts look for any anomalies in the data which might indicate engine conditions warranting further investigation. The contract effort was to develop a 'first-cut' screening system for application to SSME engine firings that would identify the relatively small volume of data which is unusual or anomalous in some way. With such a system, limited and expensive human resources could focus on this small volume of unusual data for thorough analysis. The overall project objective was to develop a fully operational Automated Propulsion Data Screening (APDS) system with the capability of detecting significant trends and anomalies in transient and steady-state data. However, the effort limited screening of transient data to ground test data for throttle-down cases typical of the 3-g acceleration, and for engine throttling required to reach the maximum dynamic pressure limits imposed on the Space Shuttle. This APDS is based on neural networks designed to detect anomalies in propulsion system data that are not part of the data used for neural network training. The delivered system allows engineers to build their own screening sets for application to completed or planned firings of the SSME. ERC developers also built some generic screening sets that NASA engineers could apply immediately to their data analysis efforts.
Critical phenomena and chemical potential of a charged AdS black hole
NASA Astrophysics Data System (ADS)
Wei, Shao-Wen; Liang, Bin; Liu, Yu-Xiao
2017-12-01
Inspired by the interpretation of the cosmological constant from the boundary gauge theory, we here treat it as the number of colors N and its conjugate quantity as the associated chemical potential μ in the black hole side. Then the thermodynamics and the chemical potential for a five-dimensional charged AdS black hole are studied. It is found that there exists a small-large black hole phase transition of van der Waals type. The critical phenomena are investigated in the N2-μ chart. The result implies that the phase transition can occur for large number of colors N , while is forbidden for small number. This to some extent implies that the interaction of the system increases with the number. In particular, in the reduced parameter space, all the thermodynamic quantities can be rescaled with the black hole charge such that these reduced quantities are charge-independent. Then we obtain the coexistence curve and the phase diagram. The latent heat is also numerically calculated. Moreover, the heat capacity and the thermodynamic scalar are studied. The result indicates that the information of the first-order black hole phase transition is encoded in the heat capacity and scalar. However, the phase transition point cannot be directly calculated with them. Nevertheless, the critical point linked to a second-order phase transition can be determined by either the heat capacity or the scalar. In addition, we calculate the critical exponents of the heat capacity and the scalar for the saturated small and large black holes near the critical point.
Immunoblotting assays for keratan sulfate.
Yoon, Jung Hae; Brooks, Randolph; Halper, Jaroslava
2002-07-15
The detection of microquantities of glycosaminoglycans (GAGs) in biological samples has been hampered by the lack of sensitive methods. In this paper we describe the modification and development of three sensitive assays capable of detecting nanogram quantities of GAGs in biological samples. The first assay detects total GAGs. It is a modified Alcian blue dye precipitation assay in which the dye binds to the negatively charged GAGs in CsCl-fractionated extracts from chicken tendons. This assay compares favorably with the widely used uronic acid assay in terms of its sensitivity and ability to detect all classes of GAGs, including keratan sulfate (KS). Two other assays, dot-blotting and immunoblotting, detect KS in complex mixtures and can be easily adapted for the detection of other GAGs. Both take advantage of binding of carboxyl and sulfate groups of GAGs to trivalent neodymium. In dot-blotting, samples were directly blotted onto nitrocellulose membrane soaked in Nd(2)(SO(4))(3) buffer, and KS was detected with the monoclonal anti-KS 5-D-4 antibody and an avidin-biotin complex detection system. In immunoblotting, the samples were first separated in 28% polyacrylamide gels, transferred onto a Nd(2)(SO(4))(3)-soaked nitrocellulose membrane using a phosphate buffer system, and stained and developed using the same protocol as in dot-blotting. Whereas dot-blotting allows the use of very low quantities of samples because of its high sensitivity (lower detection limit was 5 ng), immunoblotting provides more specificity.
Basile, Marco; Galica, Vikiela
2013-01-01
To compare the diagnostic accuracy of a consolidated method (i.e.gastrografin) and a new one (i.e.radiopaque markers) in detecting complete intestinal obstruction. Twenty-one patients with suspected small bowel obstruction were enrolled and received at admission orally 100 ml of Gastrografin and 10 radiopaque markers at the same time. A series of plain abdominal radiograms was taked and evaluated to decide whether the obstruction was complete or not. The results of radiological evaluations were not disclosed to the surgeons responsible for the patient's treatment, therefore clinical decisions were assumed on clinical grounds only. In 16 out of the 21 enrolled patients both methods demonstrated only a partial obstruction; clinically none of them required surgery. Five patients showed complete bowel obstruction by the radiopaque markers method; out of those the gastrografin study showed a complete obstruction in four of them. All of them were operated on. In the fifth case it was not clear if the gastrografin had passed through the ileum-cecal valve or not. The unclear clinical picture induced to perform a TC that revealed that a small quantity of gastrografin had passed the ileo-cecal valve but there was a complete small bowel occlusion due to an internal hernia requiring a surgical treatment (thus implying a false negative picture). This preliminary study showed that both methods are effective in the early diagnosis of complete SBO. The use of radiopaque markers could avoid some false negatives of the gastrografin method and is significantly less expensive.
Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography
Szkulmowski, Maciej; Tamborski, Szymon; Wojtkowski, Maciej
2016-01-01
We propose a simple and robust procedure for Fourier domain optical coherence tomography (FdOCT) that allows to linearize the detected FdOCT spectra to wavenumber domain and, at the same time, to determine the wavelength of light for each point of detected spectrum. We show that in this approach it is possible to use any measurable physical quantity that has linear dependency on wavenumber and can be extracted from spectral fringes. The actual values of the measured quantity have no importance for the algorithm and do not need to be known at any stage of the procedure. As example we calibrate a spectral OCT spectrometer using Doppler frequency. The technique of spectral calibration can be in principle adapted to of all kind of Fourier domain OCT devices. PMID:28018723
Chemical characterization of territorial marking fluid of male Bengal tiger, Panthera tigris.
Burger, B V; Viviers, M Z; Bekker, J P I; le Roux, M; Fish, N; Fourie, W B; Weibchen, G
2008-05-01
The territorial marking fluid of the male Bengal tiger, Panthera tigris, consists of a mixture of urine and a small quantity of lipid material that may act as a controlled-release carrier for the volatile constituents of the fluid. Using gas chromatography and gas chromatography-mass spectrometry, 98 volatile compounds and elemental sulfur were identified in the marking fluid. Another 16 volatiles were tentatively identified. The majority of these compounds were alkanols, alkanals, 2-alkanones, branched and unbranched alkanoic acids, dimethyl esters of dicarboxylic acids, gamma- and delta-lactones, and compounds containing nitrogen or sulfur. Several samples of the marking fluid contained pure (R)-3-methyl-2-octanone, (R)-3-methyl-2-nonanone, and (R)-3-methyl-2-decanone, but these ketones were partly or completely racemized in other samples. The gamma-lactone (S)-(+)-(Z)-6-dodecen-4-olide and the C(8) to C(16) saturated (R)-gamma-lactones and (S)-delta-lactones were present in high enantiomeric purities. The chiral carboxylic acids, 2-methylnonanoic acid, 2-methyldecanoic acid, 2-methylundecanoic acid, and 2-ethylhexanoic acid were racemates. Cadaverine, putrescine, and 2-acetylpyrroline, previously reported as constituents of tiger urine, were not detected. The dominant contribution of some ketones, fatty acids, and lactones to the composition of the headspace of the marking fluid suggests that these compounds may be important constituents of the pheromone. Although it constitutes only a small proportion, the lipid fraction of the fluid contained larger quantities of the volatile organic compounds than the aqueous fraction (urine). The lipid derives its role as controlled-release carrier of the chemical message left by the tiger, from its affinity for the volatiles of the marking fluid. Six proteins with masses ranging from 16 to 69 kDa, inter alia, the carboxylesterase-like urinary protein known as cauxin, previously identified in the urine of the domestic cat and other felid species, were identified in the urine fraction of the marking fluid.
21 CFR 524.1883 - Prednisolone sodium phosphate-neomycin sulfate ophthalmic ointment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of cats and dogs, such as those associated with allergic reactions or gross irritants.1 1 These... information. (2) A small quantity of the ointment should be expressed into the conjunctival sac 4 times a day...
21 CFR 524.1883 - Prednisolone sodium phosphate-neomycin sulfate ophthalmic ointment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... of cats and dogs, such as those associated with allergic reactions or gross irritants.1 1 These... information. (2) A small quantity of the ointment should be expressed into the conjunctival sac 4 times a day...
21 CFR 524.1883 - Prednisolone sodium phosphate-neomycin sulfate ophthalmic ointment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of cats and dogs, such as those associated with allergic reactions or gross irritants.1 1 These... information. (2) A small quantity of the ointment should be expressed into the conjunctival sac 4 times a day...
21 CFR 524.1883 - Prednisolone sodium phosphate-neomycin sulfate ophthalmic ointment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... of cats and dogs, such as those associated with allergic reactions or gross irritants.1 1 These... information. (2) A small quantity of the ointment should be expressed into the conjunctival sac 4 times a day...
40 CFR 257.30 - Recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 257.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 257.30 - Recordkeeping requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 257.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 257.30 - Recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 257.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 257.30 - Recordkeeping requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 257.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 273.8 - Applicability-household and conditionally exempt small quantity generator waste.
Code of Federal Regulations, 2011 CFR
2011-07-01
... managing the wastes listed below may, at their option, manage them under the requirements of this part: (1... section together with universal waste regulated under this part must manage the commingled waste under the...
40 CFR 273.8 - Applicability-household and conditionally exempt small quantity generator waste.
Code of Federal Regulations, 2012 CFR
2012-07-01
... managing the wastes listed below may, at their option, manage them under the requirements of this part: (1... section together with universal waste regulated under this part must manage the commingled waste under the...
40 CFR 273.8 - Applicability-household and conditionally exempt small quantity generator waste.
Code of Federal Regulations, 2010 CFR
2010-07-01
... managing the wastes listed below may, at their option, manage them under the requirements of this part: (1... section together with universal waste regulated under this part must manage the commingled waste under the...
40 CFR 273.8 - Applicability-household and conditionally exempt small quantity generator waste.
Code of Federal Regulations, 2013 CFR
2013-07-01
... managing the wastes listed below may, at their option, manage them under the requirements of this part: (1... section together with universal waste regulated under this part must manage the commingled waste under the...
40 CFR 273.8 - Applicability-household and conditionally exempt small quantity generator waste.
Code of Federal Regulations, 2014 CFR
2014-07-01
... managing the wastes listed below may, at their option, manage them under the requirements of this part: (1... section together with universal waste regulated under this part must manage the commingled waste under the...
Does quantity generate quality? Testing the fundamental principle of brainstorming.
Muñoz Adánez, Alfredo
2005-11-01
The purpose of this work is to test the chief principle of brainstorming, formulated as "quantity generates quality." The study is included within a broad program whose goal is to detect the strong and weak points of creative techniques. In a sample of 69 groups, containing between 3 and 8 members, the concurrence of two commonly accepted criteria was established as a quality rule: originality and utility or value. The results fully support the quantity-quality relation (r = .893): the more ideas produced to solve a problem, the better quality of the ideas. The importance of this finding, which supports Osborn's theory, is discussed, and the use of brainstorming is recommended to solve the many open problems faced by our society.
Percolation and epidemics in a two-dimensional small world
NASA Astrophysics Data System (ADS)
Newman, M. E.; Jensen, I.; Ziff, R. M.
2002-02-01
Percolation on two-dimensional small-world networks has been proposed as a model for the spread of plant diseases. In this paper we give an analytic solution of this model using a combination of generating function methods and high-order series expansion. Our solution gives accurate predictions for quantities such as the position of the percolation threshold and the typical size of disease outbreaks as a function of the density of ``shortcuts'' in the small-world network. Our results agree with scaling hypotheses and numerical simulations for the same model.
NASA Astrophysics Data System (ADS)
Zheng, L.; Weisberg, R. H.
2016-02-01
A 3D, numerical circulation model, with high resolution (20 m) at important mass conveyances (inlets and rivers etc.), is developed to estimate the bulk residence time and diagnose the salt balances and salt fluxes for Tampa Bay estuary. These analyses are justified via quantitative comparisons between the simulation and observations of sea level, velocity and salinity. The non-tidal circulation is the primary agent for the flushing of Tampa Bay. Tides alone have a minor effect. Exceptions pertain to within a tidal excursion from the bay mouth and regions with multiple inlets where different tide phases aid in flushing. The fully 3D salt flux divergences (SFD) and fluxes vary spatially throughout the estuary. On experimental duration (three month) average, the total advective SFD is balanced primarily by the vertical diffusive SFD, except near the bottom of the channel where the horizontal diffusive SFD is also important. Instantaneously, the local rate of salinity change is controlled primarily by the advective SFD, with a secondary contribution by the vertical diffusive SFD everywhere and the horizontal diffusive SFD near the channel bottom. After decomposing the advective salt fluxes and their divergences into mean quantity and tidal pumping, the horizontal and vertical advective SFDs by the mean quantities are large and counterbalance, with their sum being a small but significant residual. The horizontal and vertical advective SFDs by tidal pumping are relatively small (when compared with the mean quantities) and counterbalance; but, when summed, their residual is comparable in magnitude to that by the mean quantities. So whereas the salt fluxes by tidal pumping are secondary importance to the salt fluxes by the mean quantities, their total flux divergences are of comparable importance. The salt flux 3D components vary along the Tampa Bay axis, and these findings may be typical of coastal plain estuaries given their geometrical complexities.
Analyses of the vertical and temporal distribution of sulfate-reducing bacteria in Lake Aha (China)
NASA Astrophysics Data System (ADS)
Wang, M. Y.; Liang, X. B.; Yuan, X. Y.; Zhang, W.; Zeng, J.
2008-03-01
In April and September of 2005, two sediment cores were collected from Lake Aha, which is polluted by the acid mine drainage of the mining industries. Sulfate-reducing bacteria (SRB) groups and their quantity were analyzed by using PCR and FISH (fluorescence in situ hybridization), respectively. The results showed that four SRB groups ( Desulfotomaculum, Desulfobulbus, Desulfococcus Desulfonema Desulfosarcina and Desulfovibrio Desulfomicrobium) were detected in September, while only three SRB groups ( Desulfotomaculum, Desulfobulbus and Desulfococcus Desulfonema Desulfosarcina) were detected in April. Desulfovibrio Desulfomicrobium was not detected and was expected to exist inactively, in April. Meanwhile, the distribution of every SRB group was wider in September than in April. The results indicated that different SRB groups had different vertical and temporal distribution. The vertical and temporal distribution of SRB was mainly in the upper sediments, and the number of SRB groups and quantity were larger in September than in April. It suggested that the environmental conditions of sediments in September were more suitable for SRB.
NASA Astrophysics Data System (ADS)
Remetti, Romolo; Gandolfo, Giada; Lepore, Luigi; Cherubini, Nadia
2017-10-01
In the frame of Chemical, Biological, Radiological, and Nuclear defense European activities, the ENEA, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development, is proposing the Neutron Active Interrogation system (NAI), a device designed to find transuranic-based Radioactive Dispersal Devices hidden inside suspected packages. It is based on Differential Die-Away time Analysis, an active neutron technique targeted in revealing the presence of fissile material through detection of induced fission neutrons. Several Monte Carlo simulations, carried out by MCNPX code, and the development of ad-hoc design methods, have led to the realization of a first prototype based on a 14 MeV d-t neutron generator coupled with a tailored moderating structure, and an array of helium-3 neutron detectors. The complete system is characterized by easy transportability, light weight, and real-time response. First results have shown device's capability to detect gram quantities of fissile materials.
Ultra-Sensitive Detection of Prion Protein in Blood Using Isothermal Amplification Technology
2005-12-01
cattle products are admitted into the food chain, the Western Blot or ELISA in an antigen detection format are used to test the bovine brain stems...the most sensitive fluorescent dye (SYBR Green I, SYBR Green II, or SYBR Gold) detection of transcription products using real-time technology...RNA products from ug quantities of DNA template. Figure 3 shows that SYBR Green II exhibited higher relative fluorescence units (RFU) than SYBR
Vistas, Cláudia R; Soares, Sandra S; Rodrigues, Rogério M M; Chu, Virginia; Conde, João P; Ferreira, Guilherme N M
2014-08-07
A hydrogenated amorphous silicon (a-Si:H) photosensor was explored for the quantitative detection of a HIV-1 virion infectivity factor (Vif) at a detection limit in the single nanomolar range. The a-Si:H photosensor was coupled with a microfluidic channel that was functionalized with a recombinant single chain variable fragment antibody. The biosensor selectively recognizes HIV-1 Vif from human cell extracts.
NASA Technical Reports Server (NTRS)
Deloach, R.; Morris, A. L.; Mcbeth, R. B.
1976-01-01
A portable boundary-layer meteorological data-acquisition and analysis system is described which employs a small tethered balloon and a programmable calculator. The system is capable of measuring pressure, wet- and dry-bulb temperature, wind speed, and temperature fluctuations as a function of height and time. Other quantities, which can be calculated in terms of these, can also be made available in real time. All quantities, measured and calculated, can be printed, plotted, and stored on magnetic tape in the field during the data-acquisition phase of an experiment.
Costing the OMNIUM-G system 7500
NASA Technical Reports Server (NTRS)
Fortgang, H. R.
1980-01-01
A complete OMNIUM-G System 7500 was cost analyzed for annual production quantities ranging from 25 to 10,000 units per year. Parts and components were subjected to in-depth scrutiny to determine optimum manufacturing processes, coupled with make or buy decisions on materials and small parts. When production quantities increase both labor and material costs reduce substantially. A redesign of the system that was analyzed could result in lower costs when annual production runs approach 100,000 units/year. Material and labor costs for producing 25, 100, 25,000 and 100,00 units are given for 17 subassembly units.
Code of Federal Regulations, 2012 CFR
2012-04-01
... TREASURY (CONTINUED) TOBACCO MISCELLANEOUS REGULATIONS RELATING TO TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for... the method to use for each to determine quantities: Article Inventory method Small cigarettes Count...
40 CFR 257.27 - Selection of remedy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 257.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste Disposal Units...
40 CFR 257.25 - Assessment monitoring program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 257.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 257.27 - Selection of remedy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 257.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste Disposal Units...
Overrun in Second-Growth Yellow-Poplar
Robert A. Campbell
1959-01-01
Second-growth yellow-poplar is reaching merchantable size in the Southern Appalachians in increasing quantities each year. Although the timber is young and logs are small, it produces lumber of sufficiently high quality to supply the needs of Carolina wood-using industries.
Code of Federal Regulations, 2014 CFR
2014-04-01
... TREASURY (CONTINUED) TOBACCO MISCELLANEOUS REGULATIONS RELATING TO TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for... the method to use for each to determine quantities: Article Inventory method Small cigarettes Count...
Code of Federal Regulations, 2010 CFR
2010-04-01
... TREASURY (CONTINUED) TOBACCO MISCELLANEOUS REGULATIONS RELATING TO TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for... the method to use for each to determine quantities: Article Inventory method Small cigarettes Count...
Code of Federal Regulations, 2011 CFR
2011-04-01
... TREASURY (CONTINUED) TOBACCO MISCELLANEOUS REGULATIONS RELATING TO TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for... the method to use for each to determine quantities: Article Inventory method Small cigarettes Count...
Code of Federal Regulations, 2013 CFR
2013-04-01
... TREASURY (CONTINUED) TOBACCO MISCELLANEOUS REGULATIONS RELATING TO TOBACCO PRODUCTS AND CIGARETTE PAPERS AND TUBES Floor Stocks Tax on Certain Tobacco Products, Cigarette Papers, and Cigarette Tubes Held for... the method to use for each to determine quantities: Article Inventory method Small cigarettes Count...
40 CFR 257.10-257.12 - [Reserved
Code of Federal Regulations, 2010 CFR
2010-07-01
....10-257.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 262.213 - Laboratory clean-outs.
Code of Federal Regulations, 2013 CFR
2013-07-01
... waste or more than 100 kg/month of hazardous waste (i.e., the conditionally exempt small quantity... 262.213 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS APPLICABLE TO GENERATORS OF HAZARDOUS WASTE Alternative Requirements for Hazardous Waste...
40 CFR 262.213 - Laboratory clean-outs.
Code of Federal Regulations, 2011 CFR
2011-07-01
... waste or more than 100 kg/month of hazardous waste (i.e., the conditionally exempt small quantity... 262.213 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS APPLICABLE TO GENERATORS OF HAZARDOUS WASTE Alternative Requirements for Hazardous Waste...
Method and apparatus for monitoring the flow of mercury in a system
Grossman, Mark W.
1987-01-01
An apparatus and method for monitoring the flow of mercury in a system. The equipment enables the entrainment of the mercury in a carrier gas e.g., an inert gas, which passes as mercury vapor between a pair of optically transparent windows. The attenuation of the emission is indicative of the quantity of mercury (and its isotopes) in the system. A 253.7 nm light is shone through one of the windows and the unabsorbed light is detected through the other window. The absorption of the 253.7 nm light is thereby measured whereby the quantity of mercury passing between the windows can be determined. The apparatus includes an in-line sensor for measuring the quantity of mercury. It includes a conduit together with a pair of apertures disposed in a face to face relationship and arranged on opposite sides of the conduit. A pair of optically transparent windows are disposed upon a pair of viewing tubes. A portion of each of the tubes is disposed inside of the conduit and within each of the apertures. The two windows are disposed in a face to face relationship on the ends of the viewing tubes and the entire assembly is hermetically sealed from the atmosphere whereby when 253.7 nm ultraviolet light is shone through one of the windows and detected through the other, the quantity of mercury which is passing by can be continuously monitored due to absorption which is indicated by attenuation of the amplitude of the observed emission.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Otobe, Y.; Chikamatsu, M.
1988-03-08
A method of controlling the fuel supply to an internal combustion engine is described, wherein a quantity of fuel for supply to the engine is determined by correcting a basic value of the quantity of fuel determined as a function of at least one operating parameter of the engine by correction values dependent upon operating conditions of the engine and the determined quantity of fuel is supplied to the engine. The method comprises the steps of: (1) detecting a value of at least one predetermined operating parameter of the engine; (2) manually adjusting a single voltage creating means to setmore » an output voltage therefrom to such a desired value as to compensate for deviation of the air/fuel ratio of a mixture supplied to the engine due to variations in operating characteristics of engines between different production lots or aging changes; (3) determining a value of the predetermined one correction value corresponding to the set desired value of output voltage of the single voltage creating means, and then modifying the thus determined value in response to the detected value of the predetermined at least one operating parameter of the engine during engine operation; and (4) correcting the basic value of the quantity of fuel by the value of the predetermined one correction value having the thus modified value, and the other correction values.« less
Robust feature detection and local classification for surfaces based on moment analysis.
Clarenz, Ulrich; Rumpf, Martin; Telea, Alexandru
2004-01-01
The stable local classification of discrete surfaces with respect to features such as edges and corners or concave and convex regions, respectively, is as quite difficult as well as indispensable for many surface processing applications. Usually, the feature detection is done via a local curvature analysis. If concerned with large triangular and irregular grids, e.g., generated via a marching cube algorithm, the detectors are tedious to treat and a robust classification is hard to achieve. Here, a local classification method on surfaces is presented which avoids the evaluation of discretized curvature quantities. Moreover, it provides an indicator for smoothness of a given discrete surface and comes together with a built-in multiscale. The proposed classification tool is based on local zero and first moments on the discrete surface. The corresponding integral quantities are stable to compute and they give less noisy results compared to discrete curvature quantities. The stencil width for the integration of the moments turns out to be the scale parameter. Prospective surface processing applications are the segmentation on surfaces, surface comparison, and matching and surface modeling. Here, a method for feature preserving fairing of surfaces is discussed to underline the applicability of the presented approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nathan, S.; Loftin, B.; Abramczyk, G.
The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials (RAM), are significantly less hazardous than large amounts of the same materials. This paper describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials, under both normal and accident conditions, to perform the essential functions of material containment, subcriticality, and maintain external radiation levels withinmore » the specified limits. By placing the contents in a helium leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large dose rate outside the package. Quantifying the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings provides bounding shielding calculations that define mass limits compliant with 10 CFR 71.47 for a set of proposed SGQ isotopes. The approach is based on energy superposition with dose response calculated for a set of spectral groups for a baseline physical packaging configuration. The methodology includes using the MCNP radiation transport code to evaluate a family of neutron and photon spectral groups using the 9977 shipping package and its associated shielded containers as the base case. This results in a set of multipliers for 'dose per particle' for each spectral group. For a given isotope, the source spectrum is folded with the response for each group. The summed contribution from all isotopes determines the total dose from the RAM in the container.« less
Nagle, Doug D.; Guimaraes, Wladmir B.
2012-01-01
An assessment of the quantity and quality of stormwater runoff associated with industrial activities at Fort Gordon was conducted from January through December 2011. The assessment was provided to satisfy the requirements from a general permit that authorizes the discharge of stormwater under the National Pollutant Discharge Elimination System from a site associated with industrial activities. The stormwater quantity refers to the runoff discharge at the point and time of the runoff sampling. The study was conducted by the U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon. The initial scope of this study was to sample stormwater runoff from five stations at four industrial sites (two landfills and two heating and cooling sites). As a consequence of inadequate hydrologic conditions during 2011, no samples were collected at the two landfills; however, three samples were collected from the heating and cooling sites. The assessment included the collection of physical properties, such as water temperature, specific conductance, dissolved oxygen, and pH; the detection of suspended materials (total suspended solids, total fixed solids, total volatile solids), nutrients and organic compounds, and major and trace inorganic compounds (metals); and the detection of volatile and semivolatile organic compounds. Nutrients and organic compounds, major and trace inorganic compounds, and volatile and semivolatile organic compounds were detected above the laboratory reporting levels in all samples collected from the three stations. The detection of volatile and semivolatile organic compounds included anthracene, benzo[a]anthracene, benzo[a]pyrene, benzo[ghi]perylene, cis,1, 2-dichloroethene, dimethyl phthalate, fluoranthene, naphthalene, pyrene, acenaphthylene (station SWR11-3), and di-n-butyl phthalate (station SWR11-4).
Detecting trihalomethanes using nanoporous-carbon coated surface-acoustic-wave sensors
Siegal, Michael P.; Mowry, Curtis D.; Pfeifer, Kent B.; ...
2015-03-07
We study nanoporous-carbon (NPC) grown via pulsed laser deposition (PLD) as a sorbent coating on 96.5-MHz surface-acoustic-wave (SAW) devices to detect trihalomethanes (THMs), regulated byproducts from the chemical treatment of drinking water. Using both insertion-loss and isothermal-response measurements from known quantities of chloroform, the highest vapor pressure THM, we optimize the NPC mass-density at 1.05 ± 0.08 g/cm3 by controlling the background argon pressure during PLD. Precise THM quantities in a chlorobenzene solvent are directly injected into a separation column and detected as the phase-angle shift of the SAW device output compared to the drive signal. Using optimized NPC-coated SAWs,more » we study the chloroform response as a function of operating temperatures ranging from 10–50°C. Finally, we demonstrate individual responses from complex mixtures of all four THMs, with masses ranging from 10–2000 ng, after gas chromatography separation. As a result, estimates for each THM detection limit using a simple peak-height response evaluation are 4.4 ng for chloroform and 1 ng for bromoform; using an integrated-peak area response analysis improves the detection limits to 0.73 ng for chloroform and 0.003 ng bromoform.« less
Mishra, Rupesh K; Hayat, Akhtar; Catanante, Gaëlle; Ocaña, Cristina; Marty, Jean-Louis
2015-08-19
Contamination of food by mycotoxin occurs in minute/trace quantities. Nearly 92.5% of the cocoa samples present Ochratoxin A (OTA) levels at trace quantity. Hence, there is a necessity for a highly sensitive and selective device that can detect and quantify these organic toxins in various matrices such as cocoa beans. This work reports for the first time, a facile and label-free electrochemical impedimetric aptasensor for rapid detection and quantitation of OTA in cocoa beans. The developed aptasensor was constructed based on the diazonium-coupling reaction mechanism for the immobilization of anti-OTA-aptamer on screen printed carbon electrodes (SPCEs). The aptasensor exhibited a very good limit of detection (LOD) as low as 0.15 ng/mL, with added advantages of good selectivity and reproducibility. The increase in electron transfer resistance was linearly proportional to the OTA concentration in the range 0.15-2.5 ng/mL, with an acceptable recovery percentage (91-95%, RSD = 4.8%) obtained in cocoa samples. This work can facilitate a general model for the detection of OTA in cocoa beans based on the impedimetric aptasensor. The analysis can be performed onsite with pre-constructed and aptamer modified electrodes employing a portable EIS set up. Copyright © 2015 Elsevier B.V. All rights reserved.
Deriving Color-Color Transformations for VRI Photometry
NASA Astrophysics Data System (ADS)
Taylor, B. J.; Joner, M. D.
2006-12-01
In this paper, transformations between Cousins R-I and other indices are considered. New transformations to Cousins V-R and Johnson V-K are derived, a published transformation involving T1-T2 on the Washington system is rederived, and the basis for a transformation involving b-y is considered. In addition, a statistically rigorous procedure for deriving such transformations is presented and discussed in detail. Highlights of the discussion include (1) the need for statistical analysis when least-squares relations are determined and interpreted, (2) the permitted forms and best forms for such relations, (3) the essential role played by accidental errors, (4) the decision process for selecting terms to appear in the relations, (5) the use of plots of residuals, (6) detection of influential data, (7) a protocol for assessing systematic effects from absorption features and other sources, (8) the reasons for avoiding extrapolation of the relations, (9) a protocol for ensuring uniformity in data used to determine the relations, and (10) the derivation and testing of the accidental errors of those data. To put the last of these subjects in perspective, it is shown that rms errors for VRI photometry have been as small as 6 mmag for more than three decades and that standard errors for quantities derived from such photometry can be as small as 1 mmag or less.
Kobayashi, Amane; Sekiguchi, Yuki; Takayama, Yuki; Oroguchi, Tomotaka; Nakasako, Masayoshi
2014-11-17
Coherent X-ray diffraction imaging (CXDI) is a lensless imaging technique that is suitable for visualizing the structures of non-crystalline particles with micrometer to sub-micrometer dimensions from material science and biology. One of the difficulties inherent to CXDI structural analyses is the reconstruction of electron density maps of specimen particles from diffraction patterns because saturated detector pixels and a beam stopper result in missing data in small-angle regions. To overcome this difficulty, the dark-field phase-retrieval (DFPR) method has been proposed. The DFPR method reconstructs electron density maps from diffraction data, which are modified by multiplying Gaussian masks with an observed diffraction pattern in the high-angle regions. In this paper, we incorporated Friedel centrosymmetry for diffraction patterns into the DFPR method to provide a constraint for the phase-retrieval calculation. A set of model simulations demonstrated that this constraint dramatically improved the probability of reconstructing correct electron density maps from diffraction patterns that were missing data in the small-angle region. In addition, the DFPR method with the constraint was applied successfully to experimentally obtained diffraction patterns with significant quantities of missing data. We also discuss this method's limitations with respect to the level of Poisson noise in X-ray detection.
21 CFR 524.1484c - Neomycin sulfate, isoflupredone acetate, tetracaine hydrochloride ointment.
Code of Federal Regulations, 2010 CFR
2010-04-01
... conditions of the external ear canal, a quantity of ointment sufficient to fill the external ear canal may be... cleansed, and a small amount of the ointment applied and spread or rubbed in gently. The involved area may...
21 CFR 524.1484c - Neomycin sulfate, isoflupredone acetate, tetracaine hydrochloride ointment.
Code of Federal Regulations, 2011 CFR
2011-04-01
... conditions of the external ear canal, a quantity of ointment sufficient to fill the external ear canal may be... cleansed, and a small amount of the ointment applied and spread or rubbed in gently. The involved area may...
2016-01-01
Poland is the second largest coal producer in Europe, behind Germany. Poland produces small quantities of crude oil and natural gas and it is a net oil and natural gas importer. The country contains shale resources, but companies exploring for economically recoverable volumes have had disappointing results.
49 CFR 173.4 - Small quantities for highway and rail.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Division 6.1, Packing Group I, Hazard Zone A or B material; and (iv) [Reserved] (v) Thirty (30) mL water... of plastic having a minimum thickness of no less than 0.2 mm (0.008 inch), or earthenware, glass, or...
Research and Development Exemption for New Chemical Review under TSCA
Section 5(h)(3) of TSCA allows EPA to exempt manufacturers of chemical substances from the notice requirements if they manufacture it in small quantities for the purposed of research and development. This page gives an overview of this exemption.
40 CFR 262.202 - This subpart is optional.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Waste Determination and Accumulation of Unwanted Material for Laboratories Owned by Eligible Academic...: Eligible academic entities have the option of complying with this subpart with respect to its laboratories... exempt small quantity generators. Eligible academic entities have the option of complying with this...
40 CFR 262.202 - This subpart is optional.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Waste Determination and Accumulation of Unwanted Material for Laboratories Owned by Eligible Academic...: Eligible academic entities have the option of complying with this subpart with respect to its laboratories... exempt small quantity generators. Eligible academic entities have the option of complying with this...
40 CFR 262.202 - This subpart is optional.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Waste Determination and Accumulation of Unwanted Material for Laboratories Owned by Eligible Academic...: Eligible academic entities have the option of complying with this subpart with respect to its laboratories... exempt small quantity generators. Eligible academic entities have the option of complying with this...
Bowden, Stephen A; Wilson, Rab; Cooper, Jonathan M; Parnell, John
2010-01-01
Raman spectroscopy is a versatile analytical technique capable of characterizing the composition of both inorganic and organic materials. Consequently, it is frequently suggested as a payload on many planetary landers. Only approximately 1 in every 10(6) photons are Raman scattered; therefore, the detection of trace quantities of an analyte dispersed in a sample matrix can be much harder to achieve. To overcome this, surface-enhanced Raman scattering (SERS) and surface-enhanced resonance Raman scattering (SERRS) both provide greatly enhanced signals (enhancements between 10(5) and 10(9)) through the analyte's interaction with the locally generated surface plasmons, which occur at a "roughened" or nanostructured metallic surface (e.g., Cu, Au, and Ag). Both SERS and SERRS may therefore provide a viable technique for trace analysis of samples. In this paper, we describe the development of SERS assays for analyzing trace amounts of compounds present in the solvent extracts of sedimentary deposits. These assays were used to detect biological pigments present in an Arctic microoasis (a small locale of elevated biological productivity) and its detrital regolith, characterize the pigmentation of microbial mats around hydrothermal springs, and detect fossil organic matter in hydrothermal deposits. These field study examples demonstrate that SERS technology is sufficiently mature to be applied to many astrobiological analog studies on Earth. Many current and proposed imaging systems intended for remote deployment already posses the instrumental components needed for SERS. The addition of wet chemistry sample processing facilities to these instruments could yield field-deployable analytical instruments with a broadened analytical window for detecting organic compounds with a biological or geological origin.
A biosensor assay for the detection of Mycobacterium avium subsp. paratuberculosis in fecal samples
Kumanan, Vijayarani; Nugen, Sam R.; Baeumner, Antje J.
2009-01-01
A simple, membrane-strip-based lateral-flow (LF) biosensor assay and a high-throughput microtiter plate assay have been combined with a reverse transcriptase polymerase chain reaction (RT-PCR) for the detection of a small number (ten) of viable Mycobacterium (M.) avium subsp. paratuberculosis (MAP) cells in fecal samples. The assays are based on the identification of the RNA of the IS900 element of MAP. For the assay, RNA was extracted from fecal samples spiked with a known quantity of (101 to 106) MAP cells and amplified using RT-PCR and identified by the LF biosensor and the microtiter plate assay. While the LF biosensor assay requires only 30 min of assay time, the overall process took 10 h for the detection of 10 viable cells. The assays are based on an oligonucleotide sandwich hybridization assay format and use either a membrane flow through system with an immobilized DNA probe that hybridizes with the target sequence or a microtiter plate well. Signal amplification is provided when the target sequence hybridizes to a second DNA probe that has been coupled to liposomes encapsulating the dye, sulforhodamine B. The dye in the liposomes provides a signal that can be read visually, quantified with a hand-held reflectometer, or with a fluorescence reader. Specificity analysis of the assays revealed no cross reactivity with other mycobacteria, such as M. avium complex, M. ulcerans, M. marium, M. kansasii, M. abscessus, M. asiaticum, M. phlei, M. fortuitum, M. scrofulaceum, M. intracellulare, M. smegmatis, and M. bovis. The overall assay for the detection of live MAP organisms is comparatively less expensive and quick, especially in comparison to standard MAP detection using a culture method requiring 6-8 weeks of incubation time, and is significantly less expensive than real-time PCR. PMID:19255522
KOI-2700b—A Planet Candidate with Dusty Effluents on a 22 hr Orbit
NASA Astrophysics Data System (ADS)
Rappaport, Saul; Barclay, Thomas; DeVore, John; Rowe, Jason; Sanchis-Ojeda, Roberto; Still, Martin
2014-03-01
Kepler planet candidate KOI-2700b (KIC 8639908b), with an orbital period of 21.84 hr, exhibits a distinctly asymmetric transit profile, likely indicative of the emission of dusty effluents, and reminiscent of KIC 1255b. The host star has T eff = 4435 K, M ~= 0.63 M ⊙, and R ~= 0.57 R ⊙, comparable to the parameters ascribed to KIC 12557548. The transit egress can be followed for ~25% of the orbital period and, if interpreted as extinction from a dusty comet-like tail, indicates a long lifetime for the dust grains of more than a day. We present a semiphysical model for the dust tail attenuation and fit for the physical parameters contained in that expression. The transit is not sufficiently deep to allow for a study of the transit-to-transit variations, as is the case for KIC 1255b however, it is clear that the transit depth is slowly monotonically decreasing by a factor of ~2 over the duration of the Kepler mission. We infer a mass-loss rate in dust from the planet of ~2 lunar masses per Gyr. The existence of a second star hosting a planet with a dusty comet-like tail would help to show that such objects may be more common and less exotic than originally thought. According to current models, only quite small planets with Mp <~ 0.03 M ⊕ are likely to release a detectable quantity of dust. Thus, any "normal-looking" transit that is inferred to arise from a rocky planet of radius greater than ~1/2 R ⊕ should not exhibit any hint of a dusty tail. Conversely, if one detects an asymmetric transit due to a dusty tail, then it will be very difficult to detect the hard body of the planet within the transit because, by necessity, the planet must be quite small (i.e., <~ 0.3 R ⊕).
Li, L; Yang, L; Scudiero, D A; Miller, S A; Yu, Z-X; Stukenberg, P T; Shoemaker, R H; Kotin, R M
2007-05-01
Transcript depletion using small interfering RNA (siRNA) technology represents a potentially valuable technique for the treatment of cancer. However, delivering therapeutic quantities of siRNA into solid tumors by chemical transfection is not feasible, whereas viral vectors efficiently transduce many human tumor cell lines. Yet producing sufficient quantities of viral vectors that elicit acute and selective cytotoxicity remains a major obstacle for preclinical and clinical trials. Using the invertebrate Spodoptera frugiperda (Sf9) cell line, we were able to produce high titer stocks of cytotoxic recombinant adeno-associated virus (rAAV) that express short hairpin RNA (shRNA) and that efficiently deplete Hec1 (highly expressed in cancer 1), or Kntc2 (kinetochore-associated protein 2), a kinetochore protein directly involved in kinetochore microtubule interactions, chromosome congression and spindle checkpoint signaling. Depletion of Hec1 protein results in persistent spindle checkpoint activation followed by cell death. Because Hec1 expression and activity are only present in mitotic cells, non-dividing cells were not affected by rAAV treatment. On the basis of the results of screening 56 human tumor cell lines with three different serotype vectors, we used a tumor xenograft model to test the effects in vivo. The effects of the shHec1 vector were evident in sectioned and stained tumors. The experiments with rAAV-shRNA vectors demonstrate the utility of producing vectors in invertebrate cells to obtain sufficient concentrations and quantities for solid tumor therapy. This addresses an important requirement for cancer gene therapy, to produce cytotoxic vectors in sufficient quantities and concentrations to enable quantitative transduction and selective killing of solid tumor cells.
Large number discrimination by mosquitofish.
Agrillo, Christian; Piffer, Laura; Bisazza, Angelo
2010-12-22
Recent studies have demonstrated that fish display rudimentary numerical abilities similar to those observed in mammals and birds. The mechanisms underlying the discrimination of small quantities (<4) were recently investigated while, to date, no study has examined the discrimination of large numerosities in fish. Subjects were trained to discriminate between two sets of small geometric figures using social reinforcement. In the first experiment mosquitofish were required to discriminate 4 from 8 objects with or without experimental control of the continuous variables that co-vary with number (area, space, density, total luminance). Results showed that fish can use the sole numerical information to compare quantities but that they preferentially use cumulative surface area as a proxy of the number when this information is available. A second experiment investigated the influence of the total number of elements to discriminate large quantities. Fish proved to be able to discriminate up to 100 vs. 200 objects, without showing any significant decrease in accuracy compared with the 4 vs. 8 discrimination. The third experiment investigated the influence of the ratio between the numerosities. Performance was found to decrease when decreasing the numerical distance. Fish were able to discriminate numbers when ratios were 1:2 or 2:3 but not when the ratio was 3:4. The performance of a sample of undergraduate students, tested non-verbally using the same sets of stimuli, largely overlapped that of fish. Fish are able to use pure numerical information when discriminating between quantities larger than 4 units. As observed in human and non-human primates, the numerical system of fish appears to have virtually no upper limit while the numerical ratio has a clear effect on performance. These similarities further reinforce the view of a common origin of non-verbal numerical systems in all vertebrates.
Mahfuz, Mohammad Upal
2016-10-01
In this paper, the expressions of achievable strength-based detection probabilities of concentration-encoded molecular communication (CEMC) system have been derived based on finite pulsewidth (FP) pulse-amplitude modulated (PAM) on-off keying (OOK) modulation scheme and strength threshold. An FP-PAM system is characterized by its duty cycle α that indicates the fraction of the entire symbol duration the transmitter remains on and transmits the signal. Results show that the detection performance of an FP-PAM OOK CEMC system significantly depends on the statistical distribution parameters of diffusion-based propagation noise and intersymbol interference (ISI). Analytical detection performance of an FP-PAM OOK CEMC system under ISI scenario has been explained and compared based on receiver operating characteristics (ROC) for impulse (i.e., spike)-modulated (IM) and FP-PAM CEMC schemes. It is shown that the effects of diffusion noise and ISI on ROC can be explained separately based on their communication range-dependent statistics. With full duty cycle, an FP-PAM scheme provides significantly worse performance than an IM scheme. The paper also analyzes the performance of the system when duty cycle, transmission data rate, and quantity of molecules vary.
Aspinall-O'Dea, Mark; Pierce, Andrew; Pellicano, Francesca; Williamson, Andrew J; Scott, Mary T; Walker, Michael J; Holyoake, Tessa L; Whetton, Anthony D
2015-01-01
This protocol describes a highly reproducible antibody-based method that provides protein level and phosphorylation status information from nanogram quantities of protein cell lysate. Nanocapillary isoelectric focusing (cIEF) combines with UV-activated linking chemistry to detect changes in phosphorylation status. As an example application, we describe how to detect changes in response to tyrosine kinase inhibitors (TKIs) in the phosphorylation status of the adaptor protein CrkL, a major substrate of the oncogenic tyrosine kinase BCR-ABL in chronic myeloid leukemia (CML), using highly enriched CML stem cells and mature cell populations in vitro. This protocol provides a 2.5 pg/nl limit of protein detection (<0.2% of a stem cell sample containing <10(4) cells). Additional assays are described for phosphorylated tyrosine 207 (pTyr207)-CrkL and the protein tyrosine phosphatase PTPRC/CD45; these assays were developed using this protocol and applied to CML patient samples. This method is of high throughput, and it can act as a screen for in vitro cancer stem cell response to drugs and novel agents.
CRIM-TRACK: sensor system for detection of criminal chemical substances
NASA Astrophysics Data System (ADS)
Munk, Jens K.; Buus, Ole T.; Larsen, Jan; Dossi, Eleftheria; Tatlow, Sol; Lässig, Lina; Sandström, Lars; Jakobsen, Mogens H.
2015-10-01
Detection of illegal compounds requires a reliable, selective and sensitive detection device. The successful device features automated target acquisition, identification and signal processing. It is portable, fast, user friendly, sensitive, specific, and cost efficient. LEAs are in need of such technology. CRIM-TRACK is developing a sensing device based on these requirements. We engage highly skilled specialists from research institutions, industry, SMEs and LEAs and rely on a team of end users to benefit maximally from our prototypes. Currently we can detect minute quantities of drugs, explosives and precursors thereof in laboratory settings. Using colorimetric technology we have developed prototypes that employ disposable sensing chips. Ease of operation and intuitive sensor response are highly prioritized features that we implement as we gather data to feed into machine learning. With machine learning our ability to detect threat compounds amidst harmless substances improves. Different end users prefer their equipment optimized for their specific field. In an explosives-detecting scenario, the end user may prefer false positives over false negatives, while the opposite may be true in a drug-detecting scenario. Such decisions will be programmed to match user preference. Sensor output can be as detailed as the sensor allows. The user can be informed of the statistics behind the detection, identities of all detected substances, and quantities thereof. The response can also be simplified to "yes" vs. "no". The technology under development in CRIM-TRACK will provide custom officers, police and other authorities with an effective tool to control trafficking of illegal drugs and drug precursors.
Detecting nuclear materials smuggling: performance evaluation of container inspection policies.
Gaukler, Gary M; Li, Chenhua; Ding, Yu; Chirayath, Sunil S
2012-03-01
In recent years, the United States, along with many other countries, has significantly increased its detection and defense mechanisms against terrorist attacks. A potential attack with a nuclear weapon, using nuclear materials smuggled into the country, has been identified as a particularly grave threat. The system for detecting illicit nuclear materials that is currently in place at U.S. ports of entry relies heavily on passive radiation detectors and a risk-scoring approach using the automated targeting system (ATS). In this article we analyze this existing inspection system and demonstrate its performance for several smuggling scenarios. We provide evidence that the current inspection system is inherently incapable of reliably detecting sophisticated smuggling attempts that use small quantities of well-shielded nuclear material. To counter the weaknesses of the current ATS-based inspection system, we propose two new inspection systems: the hardness control system (HCS) and the hybrid inspection system (HYB). The HCS uses radiography information to classify incoming containers based on their cargo content into "hard" or "soft" containers, which then go through different inspection treatment. The HYB combines the radiography information with the intelligence information from the ATS. We compare and contrast the relative performance of these two new inspection systems with the existing ATS-based system. Our studies indicate that the HCS and HYB policies outperform the ATS-based policy for a wide range of realistic smuggling scenarios. We also examine the impact of changes in adversary behavior on the new inspection systems and find that they effectively preclude strategic gaming behavior of the adversary. © 2011 Society for Risk Analysis.
Narrow Band Imaging Enhances the Detection Rate of Penetration and Aspiration in FEES.
Nienstedt, Julie C; Müller, Frank; Nießen, Almut; Fleischer, Susanne; Koseki, Jana-Christiane; Flügel, Till; Pflug, Christina
2017-06-01
Narrow band imaging (NBI) is widely used in gastrointestinal, laryngeal, and urological endoscopy. Its original purpose was to visualize vessels and epithelial irregularities. Based on our observation that adding NBI to common white light (WL) improves the contrast of the test bolus in fiberoptic endoscopic evaluation of swallowing (FEES), we now investigated the potential value of NBI in swallowing disorders. 148 FEES images were analyzed from 74 consecutive patients with swallowing disorders, including 74 with and 74 without NBI. All images were evaluated by four dysphagia specialists. Findings were classified according to Rosenbek's penetration-aspiration scale modified for evaluating these FEES images. Intra- and inter-rater reliability was determined as well as observer confidence. A better visualization of the bolus is the main advantage of NBI in FEES. This generally leads to sharper optical contrasts and better detection of small bolus quantities. Accordingly, NBI enhances the detection rate of penetration and aspiration. On average, identification of laryngeal penetration increased from 40 to 73% and of aspiration from 13 to 24% (each p < 0.01) of patients. In contrast to WL alone, the use of NBI also markedly increased the inter- and intra-rater reliability (p < 0.01) and the rating confidence of all experts (p < 0.05). NBI is an easy and cost-effective tool simplifying dysphagia evaluation and shortening FEES evaluation time. It leads to a markedly higher detection rate of pathological findings. The significantly better intra- and inter-rater reliability argues further for a better overall reproducibly of FEES interpretation.
Distribution of peanut allergen in the environment.
Perry, Tamara T; Conover-Walker, Mary Kay; Pomés, Anna; Chapman, Martin D; Wood, Robert A
2004-05-01
Patients with peanut allergy can have serious reactions to very small quantities of peanut allergen and often go to extreme measures to avoid potential contact with this allergen. The purpose of this study was to detect peanut allergen under various environmental conditions and examine the effectiveness of cleaning agents for allergen removal. A monoclonal-based ELISA for Arachis hypogaea allergen 1 (Ara h 1; range of detection, 30-2000 ng/mL) was used to assess peanut contamination on cafeteria tables and other surfaces in schools, the presence of residual peanut protein after using various cleaning products on hands and tabletops, and airborne peanut allergen during the consumption of several forms of peanut. After hand washing with liquid soap, bar soap, or commercial wipes, Ara h 1 was undetectable. Plain water and antibacterial hand sanitizer left detectable Ara h 1 on 3 of 12 and 6 of 12 hands, respectively. Common household cleaning agents removed peanut allergen from tabletops, except dishwashing liquid, which left Ara h 1 on 4 of 12 tables. Of the 6 area preschools and schools evaluated, Ara h 1 was found on 1 of 13 water fountains, 0 of 22 desks, and 0 of 36 cafeteria tables. Airborne Ara h 1 was undetectable in simulated real-life situations when participants consumed peanut butter, shelled peanuts, and unshelled peanuts. The major peanut allergen, Ara h 1, is relatively easily cleaned from hands and tabletops with common cleaning agents and does not appear to be widely distributed in preschools and schools. We were not able to detect airborne allergen in many simulated environments.
An ultra-thin Schottky diode as a transmission particle detector for biological microbeams.
Grad, Michael; Harken, Andrew; Randers-Pehrson, Gerhard; Attinger, Daniel; Brenner, David J
2012-12-01
We fabricated ultrathin metal-semiconductor Schottky diodes for use as transmission particle detectors in the biological microbeam at Columbia University's Radiological Research Accelerator Facility (RARAF). The RARAF microbeam can deliver a precise dose of ionizing radiation in cell nuclei with sub-micron precision. To ensure an accurate delivery of charged particles, the facility currently uses a commercial charged-particle detector placed after the sample. We present here a transmission detector that will be placed between the particle accelerator and the biological specimen, allowing the irradiation of samples that would otherwise block radiation from reaching a detector behind the sample. Four detectors were fabricated with co-planar gold and aluminum electrodes thermally evaporated onto etched n-type crystalline silicon substrates, with device thicknesses ranging from 8.5 μm - 13.5 μm. We show coincident detections and pulse-height distributions of charged particles in both the transmission detector and the commercial detector above it. Detections are demonstrated at a range of operating conditions, including incoming particle type, count rate, and beam location on the detectors. The 13.5 μm detector is shown to work best to detect 2.7 MeV protons (H + ), and the 8.5 μm detector is shown to work best to detect 5.4 MeV alpha particles ( 4 He ++ ). The development of a transmission detector enables a range of new experiments to take place at RARAF on radiation-stopping samples such as thick tissues, targets that need immersion microscopy, and integrated microfluidic devices for handling larger quantities of cells and small organisms.
An ultra-thin Schottky diode as a transmission particle detector for biological microbeams
Harken, Andrew; Randers-Pehrson, Gerhard; Attinger, Daniel; Brenner, David J.
2013-01-01
We fabricated ultrathin metal-semiconductor Schottky diodes for use as transmission particle detectors in the biological microbeam at Columbia University’s Radiological Research Accelerator Facility (RARAF). The RARAF microbeam can deliver a precise dose of ionizing radiation in cell nuclei with sub-micron precision. To ensure an accurate delivery of charged particles, the facility currently uses a commercial charged-particle detector placed after the sample. We present here a transmission detector that will be placed between the particle accelerator and the biological specimen, allowing the irradiation of samples that would otherwise block radiation from reaching a detector behind the sample. Four detectors were fabricated with co-planar gold and aluminum electrodes thermally evaporated onto etched n-type crystalline silicon substrates, with device thicknesses ranging from 8.5 μm – 13.5 μm. We show coincident detections and pulse-height distributions of charged particles in both the transmission detector and the commercial detector above it. Detections are demonstrated at a range of operating conditions, including incoming particle type, count rate, and beam location on the detectors. The 13.5 μm detector is shown to work best to detect 2.7 MeV protons (H+), and the 8.5 μm detector is shown to work best to detect 5.4 MeV alpha particles (4He++). The development of a transmission detector enables a range of new experiments to take place at RARAF on radiation-stopping samples such as thick tissues, targets that need immersion microscopy, and integrated microfluidic devices for handling larger quantities of cells and small organisms. PMID:24058378
Method of synthesizing and growing copper-indium-diselenide (CuInSe/sub 2/) crystals
Ciszek, T.F.
1984-11-29
A process for preparing CuInSe/sub 2/ crystals includes melting a sufficient quantity of B/sub 2/O/sub 2/ along with stochiometric quantities of Cu, In, and Se in a crucible in a high-pressure atmosphere of inert gas to encapsulate the CuInSe/sub 2/ melt and confine the Se to the crucible. Additional Se in the range of 1.8 to 2.2% over the stochiometric quantity is preferred to make up for small amounts of Se lost in the process. The melt can then be cooled slowly to form the crystal as direct solidification, or the crystal can be grown by inserting a seed crystal through the B/sub 2/O/sub 3/ encapsulate into contact with the CuInSe/sub 2/ melt and withdrawing the seed upwardly to grow the crystal thereon from the melt.
Aerosol-based detectors for liquid chromatography.
Magnusson, Lars-Erik; Risley, Donald S; Koropchak, John A
2015-11-20
Aerosol-based detectors developed within the last few decades have increasingly addressed the need for sensitive, universal liquid chromatography detection in a wide variety of applications. Herein, we review the operating principles, instrumentation, analytical characteristics, and recent applications of the three general types of such detectors: evaporative light scattering detection (ELSD), condensation nucleation light scattering detection (CNLSD); commercially known as the nano-quantity analyte detector (NQAD), and charged aerosol detection (CAD). Included is a comparative evaluation of the operational and analytical characteristics of these detectors. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindquist, N.; Hay, M.E.
Marine larvae are consumed by a wide variety of generalist fishes and particle-feeding invertebrates, but larvae of any particular species probably constitute a small and variable portion of the diet for these consumers. Because virtually all consumers can ingest small quantities of noxious compounds with minimal detrimental effects, it is uncertain that toxic chemicals in larvae could be consumed in quantities sufficient to select for predator recognition and avoidance. Despite this, chemically defended larvae do occur. We show that, at low doses, secondary metabolites (the didemnins) from adults and larvae of the Caribbean tunicate Trididenmum solidum induced vomiting in fish,more » resulting in rapid learned aversion to the dedemnin-defended food. The particle-feeding anemone Aiptasia pallida did not learn to avoid the chemically defended food. When anemones ingested the chemical equivalent of 15 larvae/d, representing <2% of the mass of their total daily diet, the didemnins in the {open_quotes}larvae{close_quotes} significantly reduced: (1) growth of adults by 82%, (2) combined growth of adults and daughter clones by 76%, (3) production of daughter clones by 44%, and (4) average mass of individual daughter clones by 41%. At higher water temperatures, anemones cloned more rapidly. Significant differences in the number of daughter clones produced between treatment and control anemones occurred after only 4 d at seawater temperatures of 27{degrees}-29{degrees}C vs. 32 d at seawater temperatures of 18{degrees}-21{degrees}C. Consumption of even very small quantities of secondary metabolites can decrease consumer fitness substantially and select for predators that recognize and avoid chemically defended larvae, as do many consumers that co-occur with Trididemnum solidum larvae. This is the first rigorous demonstration that consumption of marine secondary metabolites can decrease consumer fitness when ingested at ecologically realistic doses. 59 refs., 5 figs., 3 tabs.« less
Sensitive method to monitor trace quantities of benzanthrone in workers of dyestuff industries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joshi, A.; Khanna, S.K.; Singh, G.B.
1986-03-01
Dyestuff workers coming in contact with benzanthrone (an intermediate used for the synthesis of a variety of dyes) develop skin lesions, gastritis, liver malfunctions, and sexual disturbances. A highly sensitive fluorometric method to monitor trace quantities of benzanthrone in urine, serum, and biological tissues for experimental studies, has been developed. Coupled with simple extraction and resolution, optimum fluorescence is obtained in an equal mixture of chloroform:methanol, detecting as low as 2 ng benzanthrone. This method is approximately 250 times more sensitive than currently available colorimetric assay.
Fuller, Michael P.
2017-01-01
A total of 145007 reads were obtained from pyrosequencing for all the 4 samples. The total count ranged from 11,301,014 (Mecca old road) to 23,503,512 bp (Thuwal). A total of 460 fungal species belonging to 133 genera, 58 families, 33 orders, 13 classes and 4 phyla was identified across the four sites. The most abundant phylum at all four sites was Ascomycota followed by Basidiomycota. Four phyla (Ascomycota—99.31%, Basidiomycota—0.59%, Chytridiomycota—0.04%, Glomeromycota—0.03%) were detected in Khulais. Except for Glomeromycota, all phyla were detected at Mecca old road (Ascomycota—74.26%, Basidiomycota—25.71%, Chytridiomycota—0.01%) and Thuwal (Ascomycota—99.59%, Basidiomycota—0.40%, Chytridiomycota—0.002%); while only Ascomycota—90.98% and Basidiomycota—9.01% were detected in Asfan road. At the class level, Sordariomycetes was predominantly observed at Asfan road—59.88%, Khulais—68.26% and Thuwal—94.84%; while Pezizomycetes was dominant at Mecca old road—56.01%, was absent at Asfan road. Agaricomycetes was present only at Mecca old road—25.73%; while Tremellomycetes—5.77%, Malasseizomycetes—2.13% and Microbotryomycetes—1.10% were found only at Asfan road. The phylogenetic trees revealed that clear genus level differences are visible across all the four sites, with an overall predominance of Thielavia followed by Madurella, Aspergillus, and Gelasinospora. Chaetomium sp., Aspergillus caespitosus and Aspergillus sp. were found in moderate (Mecca old road and Thuwal) to abundant (Asfan road and Khulais) quantities. Thielavia sp., Thielavia hyalocarpa and Madurella sp. are found in moderate quantities at Khulais and Mecca old road, while in abundant levels at Asfan road and Thuwal. Fusarium equisati and F. oxysporum were detected at Thuwal and Khulais. Sordaria araneosa was present at Khulais, while Malasseiza globosa species was detected in moderate quantities across all sites except Khulais. PMID:28934322
Moussa, Tarek A A; Al-Zahrani, Hassan S; Almaghrabi, Omar A; Abdelmoneim, Tamer S; Fuller, Michael P
2017-01-01
A total of 145007 reads were obtained from pyrosequencing for all the 4 samples. The total count ranged from 11,301,014 (Mecca old road) to 23,503,512 bp (Thuwal). A total of 460 fungal species belonging to 133 genera, 58 families, 33 orders, 13 classes and 4 phyla was identified across the four sites. The most abundant phylum at all four sites was Ascomycota followed by Basidiomycota. Four phyla (Ascomycota-99.31%, Basidiomycota-0.59%, Chytridiomycota-0.04%, Glomeromycota-0.03%) were detected in Khulais. Except for Glomeromycota, all phyla were detected at Mecca old road (Ascomycota-74.26%, Basidiomycota-25.71%, Chytridiomycota-0.01%) and Thuwal (Ascomycota-99.59%, Basidiomycota-0.40%, Chytridiomycota-0.002%); while only Ascomycota-90.98% and Basidiomycota-9.01% were detected in Asfan road. At the class level, Sordariomycetes was predominantly observed at Asfan road-59.88%, Khulais-68.26% and Thuwal-94.84%; while Pezizomycetes was dominant at Mecca old road-56.01%, was absent at Asfan road. Agaricomycetes was present only at Mecca old road-25.73%; while Tremellomycetes-5.77%, Malasseizomycetes-2.13% and Microbotryomycetes-1.10% were found only at Asfan road. The phylogenetic trees revealed that clear genus level differences are visible across all the four sites, with an overall predominance of Thielavia followed by Madurella, Aspergillus, and Gelasinospora. Chaetomium sp., Aspergillus caespitosus and Aspergillus sp. were found in moderate (Mecca old road and Thuwal) to abundant (Asfan road and Khulais) quantities. Thielavia sp., Thielavia hyalocarpa and Madurella sp. are found in moderate quantities at Khulais and Mecca old road, while in abundant levels at Asfan road and Thuwal. Fusarium equisati and F. oxysporum were detected at Thuwal and Khulais. Sordaria araneosa was present at Khulais, while Malasseiza globosa species was detected in moderate quantities across all sites except Khulais.
A tag-based approach for high-throughput analysis of CCWGG methylation.
Denisova, Oksana V; Chernov, Andrei V; Koledachkina, Tatyana Y; Matvienko, Nicholas I
2007-10-15
Non-CpG methylation occurring in the context of CNG sequences is found in plants at a large number of genomic loci. However, there is still little information available about non-CpG methylation in mammals. Efficient methods that would allow detection of scarcely localized methylated sites in small quantities of DNA are required to elucidate the biological role of non-CpG methylation in both plants and animals. In this study, we tested a new whole genome approach to identify sites of CCWGG methylation (W is A or T), a particular case of CNG methylation, in genomic DNA. This technique is based on digestion of DNAs with methylation-sensitive restriction endonucleases EcoRII-C and AjnI. Short DNAs flanking methylated CCWGG sites (tags) are selectively purified and assembled in tandem arrays of up to nine tags. This allows high-throughput sequencing of tags, identification of flanking regions, and their exact positions in the genome. In this study, we tested specificity and efficiency of the approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pyon, K.H.; Kracko, D.A.; Strunk, M.R.
1995-12-01
The existence of a nose-brain barrier that functions to protect the central nervous system (CNS) from inhaled toxicants has been postulated. Just as a blood-brain barrier protects the CNS from systemic toxicants, the nose-brain barrier may have similar characteristic functions. One component of interest is nasal xenobiotic metabolism and its effect on the transport of pollutants into the CNS at environmentally plausible levels of exposure. Previous results have shown that inhaled xylene are dimethyl phenol (DMP) and methyl benzyl alcohol (MBA), and the nonvolatile metabolites are toluic acid (TA) and methyl hippuric acid (MHA). The nonvolatile metabolites of xylene, alongmore » with a small quantity of volatiles, representing either parent xylene or volatile metabolites, are transported via the olfactory epithelium to the glomeruli within the olfactory bulbs of the brain. Further work will be done to establish the linearity for each analyte at the actual highest detection limit of the GC/MS.« less
Forest Attributes from Radar Interferometric Structure and its Fusion with Optical Remote Sensing
NASA Technical Reports Server (NTRS)
Treuhaft, Robert N.; Law, Beverly E.; Asner, Gregory P.
2004-01-01
The possibility of global, three-dimensional remote sensing of forest structure with interferometric synthetic aperture radar (InSAR) bears on important forest ecological processes, particularly the carbon cycle. InSAR supplements two-dimensional remote sensing with information in the vertical dimension. Its strengths in potential for global coverage complement those of lidar (light detecting and ranging), which has the potential for high-accuracy vertical profiles over small areas. InSAR derives its sensitivity to forest vertical structure from the differences in signals received by two, spatially separate radar receivers. Estimation of parameters describing vertical structure requires multiple-polarization, multiple-frequency, or multiple-baseline InSAR. Combining InSAR with complementary remote sensing techniques, such as hyperspectral optical imaging and lidar, can enhance vertical-structure estimates and consequent biophysical quantities of importance to ecologists, such as biomass. Future InSAR experiments will supplement recent airborne and spaceborne demonstrations, and together with inputs from ecologists regarding structure, they will suggest designs for future spaceborne strategies for measuring global vegetation structure.
Fenoll, José; Garrido, Isabel; Vela, Nuria; Ros, Caridad; Navarro, Simón
2017-04-01
The leaching potential of three insecticides (spirodiclofen, spiromesifen, and spirotetramat) was assessed using disturbed soil columns. Small quantities of spirodiclofen and spiromesifen were detected in leachate fraction, while spirotetramat residues were not found in the leachates. In addition, the transformation products (enol derivatives) are relatively more mobile than the parent compounds and may leach into groundwater. Moreover, the use of disinfection soil techniques (solarization and biosolarization) to enhance their degradation rates in soil was investigated. The results show that both practices achieved a reduction in the number of juvenile nematodes, enhancing in a parallel way degradation rates of the insecticides and their enol derivatives as compared with the non-disinfected soil. This behavior can be mainly attributed to the increase in soil temperature and changes in microbial activity. All insecticides showed similar behavior under solarization and biosolarization conditions. As a consequence, both agronomic techniques could be considered as suitable strategies for detoxification of soils polluted with the studied pesticides.
Elemental sulfur identified in urine of cheetah, Acinonyx jubatus.
Burger, Ben V; Visser, Runine; Moses, Alvira; Le Roux, Maritha
2006-06-01
The urine of the cheetah, Acinonyx jubatus, is almost odorless, and probably for this reason, it has not attracted much attention from scientists. Using gas chromatography-mass spectrometry, we identified 27 and 37 constituents in the headspace vapor of the urine of male and female cheetah, respectively. These constituents, composed of hydrocarbons, short-chain ethers, aldehydes, saturated and unsaturated cyclic and acyclic ketones, 2-acetylfuran, dimethyl disulfide, dimethyl sulfone, phenol, myristic acid (tetradecanoic acid), urea, and elemental sulfur, are all present in the headspace vapor in very small quantities; dimethyl disulfide is present in such a low concentration that it cannot be detected by the human nose. This is only the second example of elemental sulfur being secreted or excreted by an animal. It is hypothesized that the conversion of sulfur-containing compounds in the cheetah's diet to elemental sulfur and to practically odorless dimethyl sulfone enables this carnivore to operate as if "invisible" to the olfactory world of its predators as well as its prey, which would increase its chances of survival.
ESTIMATING WELFARE IN INSURANCE MARKETS USING VARIATION IN PRICES*
Einav, Liran; Finkelstein, Amy; Cullen, Mark R.
2009-01-01
We provide a graphical illustration of how standard consumer and producer theory can be used to quantify the welfare loss associated with inefficient pricing in insurance markets with selection. We then show how this welfare loss can be estimated empirically using identifying variation in the price of insurance. Such variation, together with quantity data, allows us to estimate the demand for insurance. The same variation, together with cost data, allows us to estimate how insurer’s costs vary as market participants endogenously respond to price. The slope of this estimated cost curve provides a direct test for both the existence and nature of selection, and the combination of demand and cost curves can be used to estimate welfare. We illustrate our approach by applying it to data on employer-provided health insurance from one specific company. We detect adverse selection but estimate that the quantitative welfare implications associated with inefficient pricing in our particular application are small, in both absolute and relative terms. PMID:21218182
Ultrasonic characterization of single drops of liquids
Sinha, D.N.
1998-04-14
Ultrasonic characterization of single drops of liquids is disclosed. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-quality measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities. 5 figs.
Ultrasonic characterization of single drops of liquids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinha, D.N.
Ultrasonic characterization of single drops of liquids is disclosed. The present invention includes the use of two closely spaced transducers, or one transducer and a closely spaced reflector plate, to form an interferometer suitable for ultrasonic characterization of droplet-size and smaller samples without the need for a container. The droplet is held between the interferometer elements, whose distance apart may be adjusted, by surface tension. The surfaces of the interferometer elements may be readily cleansed by a stream of solvent followed by purified air when it is desired to change samples. A single drop of liquid is sufficient for high-qualitymore » measurement. Examples of samples which may be investigated using the apparatus and method of the present invention include biological specimens (tear drops; blood and other body fluid samples; samples from tumors, tissues, and organs; secretions from tissues and organs; snake and bee venom, etc.) for diagnostic evaluation, samples in forensic investigations, and detection of drugs in small quantities. 5 figs.« less
Hsieh, Hua-Yi; Li, Li-Hua; Hsu, Ren-Yu; Kao, Wei-Fong; Huang, Ying-Chen; Hsu, Cheng-Chih
2017-06-06
Blood testing for endogenous small metabolites to determine physiological and biochemical states is routine for laboratory analysis. Here we demonstrate that by combining the commercial direct analysis in real time (DART) ion source with an ion trap mass spectrometer, native cholesterol in its free alcohol form is readily detected from a few hundred nanoliters of human serum loaded onto chromatography paper. Deuterium-labeled cholesterol was used as the internal standard to obtain the absolute quantity of the endogenous cholesterol. The amount of the cholesterol measured by this paper-loaded DART mass spectrometry (pDART-MS) is statistically comparable with that obtained by using commercially available fluorometric-enzymatic assay and liquid chromatography/mass spectrometry. Furthermore, sera from 21 participants at three different time points in an ultramarathon were collected to obtain their cholesterol levels. The test requires only very minimal sample preparation, and the concentrations of cholesterol in each sample were acquired within a minute.
Hung, Lien-Yu; Wang, Chih-Hung; Fu, Chien-Yu; Gopinathan, Priya; Lee, Gwo-Bin
2016-08-07
Microfluidic technologies have miniaturized a variety of biomedical applications, and these chip-based systems have several significant advantages over their large-scale counterparts. Recently, this technology has been used for automating labor-intensive and time-consuming screening processes, whereby affinity reagents, including aptamers, peptides, antibodies, polysaccharides, glycoproteins, and a variety of small molecules, are used to probe for molecular biomarkers. When compared to conventional methods, the microfluidic approaches are faster, more compact, require considerably smaller quantities of samples and reagents, and can be automated. Furthermore, they allow for more precise control of reaction conditions (e.g., pH, temperature, and shearing forces) such that more efficient screening can be performed. A variety of affinity reagents for targeting cancer cells or cancer biomarkers are now available and will likely replace conventional antibodies. In this review article, the selection of affinity reagents for cancer cells or cancer biomarkers on microfluidic platforms is reviewed with the aim of highlighting the utility of such approaches in cancer diagnostics.
1988 environmental monitoring report, Sandia National Laboratories, Albuquerque, New Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Millard, G.; Yeager, G.; Phelan, J.
1989-05-01
Sandia National Laboratories (SNL), Albuquerque is located south of Albuquerque on Kirtland Air Force Base. Because radionuclides are potentially released in small quantities from its research activities, SNL, Albuquerque has a continuing environmental monitoring program which analyzes for cesium-137, tritium, uranium, alpha emitters, and beta emitters in water, soil, air, and vegetation. A total of 5.23 curies of argon-41 were released as a result of SNL, Albuquerque operations in 1988. The albuquerque population received an estimated 0.04 person-rem from airborne radioactive releases, whereas it received greater than 44,500 person-rem from naturally occurring radionuclides. A nonradioactive effluent monitoring program at SNL,more » Albuquerque includes groundwater, stormwater and sewage monitoring. Results indicate that the groundwater has not been impacted by the chemical waste landfill. Preliminary testing of stormwater showed that no pollutants were above minimum detectable levels. A program to investigate potential remedial action sites has been started. 47 refs., 12 figs., 19 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Birkner, R.; Meyer, R.; Trautmann, J.
1957-01-01
ABS>The effect of small doses of whole-body x radiation on the septicemia caused by Klebsiella pneumoniac Friedlander in white mice depends on the moment of the irradiation, the dose, the temporal dose distribution, the age and the sex of the animals, as well as on the quantity of germs applied. Animals die more rapidly if irradiations have been applied previous to the infection, while irradiations after infections lead to longer life. (auth)
ERIC Educational Resources Information Center
Walker, Jearl
1981-01-01
Describes a method to detect the presence of microgram quantities of nearly any metal in samples of alloys, minerals, water, and air. This chemical-spot testing technique requires no elaborate equipment and can be done by an amateur. (SK)
Dialysis Extraction for Chromatography
NASA Technical Reports Server (NTRS)
Jahnsen, V. J.
1985-01-01
Chromatographic-sample pretreatment by dialysis detects traces of organic contaminants in water samples analyzed in field with minimal analysis equipment and minimal quantities of solvent. Technique also of value wherever aqueous sample and solvent must not make direct contact.
40 CFR 273.16 - Employee training.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Employee training. 273.16 Section 273.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... Employee training. A small quantity handler of universal waste must inform all employees who handle or have...
40 CFR 273.16 - Employee training.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Employee training. 273.16 Section 273.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... Employee training. A small quantity handler of universal waste must inform all employees who handle or have...
ERIC Educational Resources Information Center
Brett, Robin; Hanshaw, Bruce B.
1978-01-01
The past year has seen the development of certain fields of geochemical research including Nd-Sm isotope studies of meteorites and ancient terrestrial rocks; the use of the consortium approach of assembling a multidisciplined team to tackle a problem; and the handling and analysis of small quantities of materials. (Author/MA)
Code of Federal Regulations, 2014 CFR
2014-07-01
... natural gas (LNG) means a liquid or semisolid consisting mostly of methane and small quantities of ethane...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS General § 127.005 Definitions. As used in this part: Active means accomplishing the transfer of LHG or LNG...
Code of Federal Regulations, 2013 CFR
2013-07-01
... natural gas (LNG) means a liquid or semisolid consisting mostly of methane and small quantities of ethane...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS General § 127.005 Definitions. As used in this part: Active means accomplishing the transfer of LHG or LNG...
40 CFR 220.3 - Categories of permits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 220.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING GENERAL..., and research permits for ocean dumping under section 102 of the Act. (a) General permits. General... impact and are generally disposed of in small quantities, or for specific classes of materials that must...
40 CFR 220.3 - Categories of permits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 220.3 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING GENERAL..., and research permits for ocean dumping under section 102 of the Act. (a) General permits. General... impact and are generally disposed of in small quantities, or for specific classes of materials that must...
40 CFR 273.15 - Accumulation time limits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... individual item of universal waste (e.g., each battery or thermostat) with the date it became a waste or was... Section 273.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste...
40 CFR 273.15 - Accumulation time limits.
Code of Federal Regulations, 2011 CFR
2011-07-01
... individual item of universal waste (e.g., each battery or thermostat) with the date it became a waste or was... Section 273.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste...
40 CFR 273.15 - Accumulation time limits.
Code of Federal Regulations, 2010 CFR
2010-07-01
... individual item of universal waste (e.g., each battery or thermostat) with the date it became a waste or was... Section 273.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste...
40 CFR 273.15 - Accumulation time limits.
Code of Federal Regulations, 2014 CFR
2014-07-01
... individual item of universal waste (e.g., each battery or thermostat) with the date it became a waste or was... Section 273.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste...
40 CFR 273.15 - Accumulation time limits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... individual item of universal waste (e.g., each battery or thermostat) with the date it became a waste or was... Section 273.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT Standards for Small Quantity Handlers of Universal Waste...
PROCESS OF PREPARING URANIUM CARBIDE
Miller, W.E.; Stethers, H.L.; Johnson, T.R.
1964-03-24
A process of preparing uranium monocarbide is de scribed. Uranium metal is dissolved in cadmium, zinc, cadmium-- zinc, or magnesium-- zinc alloy and a small quantity of alkali metal is added. Addition of stoichiometric amounts of carbon at 500 to 820 deg C then precipitates uranium monocarbide. (AEC)
Method and Mechanisms of Soil Stabilization Using Electric Arc Furnace Dust
Al-Amoudi, Omar S. Baghabra; Al-Homidy, Abdullah A.; Maslehuddin, Mohammed; Saleh, Tawfik A.
2017-01-01
This paper reports the method and mechanism for improving the strength of marl and desert sand utilizing electric arc furnace dust (EAFD), an industrial by-product, in lieu of cement or lime. EAFD was used in conjunction with a small quantity (2%) of cement. The mechanical properties and durability characteristics of marl and sand mixed with 2% cement plus 5-, 10-, 20- or 30%-EAFD, by weight of the soil, were evaluated. The soil-cement-EAFD mixtures were used to determine their unconfined compressive strength (UCS), soaked California Bearing Ratio (CBR) and durability. The risk of leaching of toxic heavy metals, such as lead and cadmium, from the stabilized soils to the groundwater was also investigated. The mechanisms of stabilization of the selected soils due to the use of EAFD along with a small quantity of cement are also elucidated. The usage of 20 to 30% EAFD with 2% cement was noted to considerably improve the mechanical properties and durability of both marl and sand. PMID:28452346
Small-scale dynamic confinement gap test
NASA Astrophysics Data System (ADS)
Cook, Malcolm
2011-06-01
Gap tests are routinely used to ascertain the shock sensitiveness of new explosive formulations. The tests are popular since that are easy and relatively cheap to perform. However, with modern insensitive formulations with big critical diameters, large test samples are required. This can make testing and screening of new formulations expensive since large quantities of test material are required. Thus a new test that uses significantly smaller sample quantities would be very beneficial. In this paper we describe a new small-scale test that has been designed using our CHARM ignition and growth routine in the DYNA2D hydrocode. The new test is a modified gap test and uses detonating nitromethane to provide dynamic confinement (instead of a thick metal case) whilst exposing the sample to a long duration shock wave. The long duration shock wave allows less reactive materials that are below their critical diameter, more time to react. We present details on the modelling of the test together with some preliminary experiments to demonstrate the potential of the new test method.
Method and Mechanisms of Soil Stabilization Using Electric Arc Furnace Dust
NASA Astrophysics Data System (ADS)
Al-Amoudi, Omar S. Baghabra; Al-Homidy, Abdullah A.; Maslehuddin, Mohammed; Saleh, Tawfik A.
2017-04-01
This paper reports the method and mechanism for improving the strength of marl and desert sand utilizing electric arc furnace dust (EAFD), an industrial by-product, in lieu of cement or lime. EAFD was used in conjunction with a small quantity (2%) of cement. The mechanical properties and durability characteristics of marl and sand mixed with 2% cement plus 5-, 10-, 20- or 30%-EAFD, by weight of the soil, were evaluated. The soil-cement-EAFD mixtures were used to determine their unconfined compressive strength (UCS), soaked California Bearing Ratio (CBR) and durability. The risk of leaching of toxic heavy metals, such as lead and cadmium, from the stabilized soils to the groundwater was also investigated. The mechanisms of stabilization of the selected soils due to the use of EAFD along with a small quantity of cement are also elucidated. The usage of 20 to 30% EAFD with 2% cement was noted to considerably improve the mechanical properties and durability of both marl and sand.
Guaifenesin- and ephedrine-induced stones.
Assimos, D G; Langenstroer, P; Leinbach, R F; Mandel, N S; Stern, J M; Holmes, R P
1999-11-01
We report a new type of drug-induced stone that is caused by overconsumption of preparations containing guaifenesin and ephedrine. Clinical and stone analysis data from the Molecular Structure Laboratory at the Veterans Affairs Medical Center in Milwaukee, Wisconsin, were reviewed. Stone analysis was performed by Fourier transform infrared spectroscopy, high-resolution X-ray crystallographic powder diffraction, or both. The urine and stone material from one of the subjects were analyzed with high-performance liquid chromatography. Stone analysis from seven patients demonstrated metabolites of guaifenesin. High-performance liquid chromatography revealed that the stone and urine from one subject had a high content of guaifenesin metabolites and a small amount of ephedrine. Demographic data were available on five patients. Three had a history of alcohol or drug dependency. All were consuming over-the-counter preparations containing ephedrine and guaifenesin. Four admitted to taking excessive quantities of these agents, mainly as a stimulant. Hypocitraturia was identified in two individuals subjected to urinary metabolic testing. These stones are radiolucent on standard X-ray imaging but can be demonstrated on unenhanced CT. Shockwave lithotripsy was performed in two patients, and the calculi fragmented easily. Individuals consuming large quantities of preparations containing ephedrine and guaifenesin may be at risk to develop stones derived mainly from metabolites of guaifenesin and small quantities of ephedrine. These patients may be prone to drug or alcohol dependency.
Abdai, Judit; Gergely, Anna; Petró, Eszter; Topál, József; Miklósi, Ádám
2015-01-01
The nature of mental representation of others plays a crucial role in social interactions. Dogs present an ideal model species for the investigation of such mental representations because they develop social ties with both conspecifics and heterospecifics. Former studies found that dogs' preference for larger food quantity could be reversed by humans who indicate the smaller quantity. The question is whether this social bias is restricted to human partners. We suggest that after a short positive social experience, an unfamiliar moving inanimate agent (UMO) can also change dogs' choice between two food quantities. We tested four groups of dogs with different partners: In the (1) Helper UMO and (2) Helper UMO Control groups the partner was an interactive remote control car that helped the dog to obtain an otherwise unreachable food. In the (3) Non-helper UMO and (4) Human partner groups dogs had restricted interaction with the remote control car and the unfamiliar human partners. In the Human partner, Helper UMO and Helper UMO Control groups the partners were able to revert dogs' choice for the small amount by indicating the small one, but the Non-helper UMO was not. We suggest that dogs are able to generalize their wide range of experiences with humans to another type of agent as well, based on the recognition of similarities in simple behavioural patterns.
Abdai, Judit; Gergely, Anna; Petró, Eszter; Topál, József; Miklósi, Ádám
2015-01-01
The nature of mental representation of others plays a crucial role in social interactions. Dogs present an ideal model species for the investigation of such mental representations because they develop social ties with both conspecifics and heterospecifics. Former studies found that dogs’ preference for larger food quantity could be reversed by humans who indicate the smaller quantity. The question is whether this social bias is restricted to human partners. We suggest that after a short positive social experience, an unfamiliar moving inanimate agent (UMO) can also change dogs’ choice between two food quantities. We tested four groups of dogs with different partners: In the (1) Helper UMO and (2) Helper UMO Control groups the partner was an interactive remote control car that helped the dog to obtain an otherwise unreachable food. In the (3) Non-helper UMO and (4) Human partner groups dogs had restricted interaction with the remote control car and the unfamiliar human partners. In the Human partner, Helper UMO and Helper UMO Control groups the partners were able to revert dogs’ choice for the small amount by indicating the small one, but the Non-helper UMO was not. We suggest that dogs are able to generalize their wide range of experiences with humans to another type of agent as well, based on the recognition of similarities in simple behavioural patterns. PMID:26241747
Leitman, Patricia L.; Hall, D.W.; Langland, M.J.; Chichester, D.C.; Ward, J.R.
1996-01-01
Surface-runoff and ground-water quantity and quality of a 22.1-acre field site were characterized from January 1983 through September 1984, before implementation of terracing and nutrient-management practices. The site, underlain by carbonate rock, was cropland used primarily for the production of corn and alfalfa. Average annual application of nutrients to the 14.4 acres of cornfields was 410 pounds of nitrogen and 110 pounds of phosphorus. About three times more nutrients were applied during the 1984 water year than during the 1983 water year. During the investigation, 714,000 cubic feet of runoff transported 244 tons of suspended sediment, 300 pounds of nitrogen, and 170 pounds of phosphorus during the 1984 water year. Runoff from storms on frozen ground produced the highest loads of nitrogen. Regression analyses indicate that runoff rates and quantities were controlled by precipitation intensities of quantities and the amount of crop cover, and that mean concentrations of nitrogen for runoff events increased with increased surface-nitrogen applications made prior to runoff. Ground-water levels responded quickly to recharge, with peaks occurring several hours to a day after precipitation. Median concentrations of dissolved nitrate in ground water ranged from 9.2 to 13 milligrams per liter as nitrogen. A lag time of 1 to 3 months was observed between the time that nitrogen was applied to the land surface and local maximums in nitrate concentrations were detected in ground water unaffected by recharge events. About 3 million cubic feet of ground water and an associated 2,200 pounds of nitrate-nitrogen discharged from the site during the study period. For the study period, 42 percent of the precipitation recharged to ground water, 10 percent became runoff, and 48 percent evapotranspired. Inputs of nitrogen to the study area were estimated to be 93 percent from manure, 5 percent from commercial fertilizer, and 2 percent from precipitation. Nitrogen outputs from the system were estimated to be 38 percent to crop uptake, 39 percent to volatilization, 20 percent to ground- water discharge, and 3 percent to surface runoff.
A robust methodology to subclassify pseudokinases based on their nucleotide-binding properties
Murphy, James M.; Zhang, Qingwei; Young, Samuel N.; Reese, Michael L.; Bailey, Fiona P.; Eyers, Patrick A.; Ungureanu, Daniela; Hammaren, Henrik; Silvennoinen, Olli; Varghese, Leila N.; Chen, Kelan; Tripaydonis, Anne; Jura, Natalia; Fukuda, Koichi; Qin, Jun; Nimchuk, Zachary; Mudgett, Mary Beth; Elowe, Sabine; Gee, Christine L.; Liu, Ling; Daly, Roger J.; Manning, Gerard; Babon, Jeffrey J.; Lucet, Isabelle S.
2017-01-01
Protein kinase-like domains that lack conserved residues known to catalyse phosphoryl transfer, termed pseudokinases, have emerged as important signalling domains across all kingdoms of life. Although predicted to function principally as catalysis-independent protein-interaction modules, several pseudokinase domains have been attributed unexpected catalytic functions, often amid controversy. We established a thermal-shift assay as a benchmark technique to define the nucleotide-binding properties of kinase-like domains. Unlike in vitro kinase assays, this assay is insensitive to the presence of minor quantities of contaminating kinases that may otherwise lead to incorrect attribution of catalytic functions to pseudokinases. We demonstrated the utility of this method by classifying 31 diverse pseudokinase domains into four groups: devoid of detectable nucleotide or cation binding; cation-independent nucleotide binding; cation binding; and nucleotide binding enhanced by cations. Whereas nine pseudokinases bound ATP in a divalent cation-dependent manner, over half of those examined did not detectably bind nucleotides, illustrating that pseudokinase domains predominantly function as non-catalytic protein-interaction modules within signalling networks and that only a small subset is potentially catalytically active. We propose that henceforth the thermal-shift assay be adopted as the standard technique for establishing the nucleotide-binding and catalytic potential of kinase-like domains. PMID:24107129
Dama, Elisa; Tillhon, Micol; Bertalot, Giovanni; de Santis, Francesca; Troglio, Flavia; Pessina, Simona; Passaro, Antonio; Pece, Salvatore; de Marinis, Filippo; Dell'Orto, Patrizia; Viale, Giuseppe; Spaggiari, Lorenzo; Di Fiore, Pier Paolo; Bianchi, Fabrizio; Barberis, Massimo; Vecchi, Manuela
2016-01-01
Accurate detection of altered anaplastic lymphoma kinase (ALK) expression is critical for the selection of lung cancer patients eligible for ALK-targeted therapies. To overcome intrinsic limitations and discrepancies of currently available companion diagnostics for ALK, we developed a simple, affordable and objective PCR-based predictive model for the quantitative measurement of any ALK fusion as well as wild-type ALK upregulation. This method, optimized for low-quantity/−quality RNA from FFPE samples, combines cDNA pre-amplification with ad hoc generated calibration curves. All the models we derived yielded concordant predictions when applied to a cohort of 51 lung tumors, and correctly identified all 17 ALK FISH-positive and 33 of the 34 ALK FISH-negative samples. The one discrepant case was confirmed as positive by IHC, thus raising the accuracy of our test to 100%. Importantly, our method was accurate when using low amounts of input RNA (10 ng), also in FFPE samples with limited tumor cellularity (5–10%) and in FFPE cytology specimens. Thus, our test is an easily implementable diagnostic tool for the rapid, efficacious and cost-effective screening of ALK status in patients with lung cancer. PMID:27206799
NASA Astrophysics Data System (ADS)
Corregidor, V.; Oliveira, A. R.; Rodrigues, P. A.; Alves, L. C.
2015-04-01
Resorting to an external proton microbeam, PIXE analyses of three oil paintings on copper support dated from the XVII century and attributed to the Flemish artist Frans Francken II, were undertaken. The present work aims to contribute to the compositional study of the painting materials employed by XVII century artists that exploited copper as a support for oil painting, and specifically the materials used by Francken's workshop, particularly copper plates. Because of the low thickness of the pictorial layers of this type of paintings and its non-destructive character, PIXE is the ideal technique to study the elemental composition of the paintings. Several spots in each painting were chosen for analysis in order to cover almost all the pigments used in the colour palette. Lead and calcium were detected in practically every analysed regions, probably related to the presence of lead white and chalk, usually used as ground layer on copper paintings. Small quantities of gold were also detected, which is present in many of this artist's works to embellish some details of the representations. Also this work reports the first application of the external proton microbeam set-up available at CTN/IST in Portugal for the characterization of oil paintings.
Neutron reflectometry on highly absorbing films and its application to 10B4C-based neutron detectors
Piscitelli, F.; Khaplanov, A.; Devishvili, A.; Schmidt, S.; Höglund, C.; Birch, J.; Dennison, A. J. C.; Gutfreund, P.; Hall-Wilton, R.; Van Esch, P.
2016-01-01
Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. The absorption in the typical studied materials is neglected and this technique is limited only to the reflectivity measurement. For strongly absorbing nuclei, the absorption can be directly measured by using the neutron-induced fluorescence technique which exploits the prompt particle emission of absorbing isotopes. This technique is emerging from soft matter and biology where highly absorbing nuclei, in very small quantities, are used as a label for buried layers. Nowadays, the importance of absorbing layers is rapidly increasing, partially because of their application in neutron detection; a field that has become more active also due to the 3He-shortage. We extend the neutron-induced fluorescence technique to the study of layers of highly absorbing materials, in particular 10B4C. The theory of neutron reflectometry is a commonly studied topic; however, when a strong absorption is present the subtle relationship between the reflection and the absorption of neutrons is not widely known. The theory for a general stack of absorbing layers has been developed and compared to measurements. We also report on the requirements that a 10B4C layer must fulfil in order to be employed as a converter in neutron detection. PMID:26997902
Alvino, Jason F; Bennett, Trystan; Kler, Rantej; Hudson, Rohan J; Aupoil, Julien; Nann, Thomas; Golovko, Vladimir B; Andersson, Gunther G; Metha, Gregory F
2017-05-01
A high-temperature, high-pressure, pulsed-gas sampling and detection system has been developed for testing new catalytic and photocatalytic materials for the production of solar fuels. The reactor is fitted with a sapphire window to allow the irradiation of photocatalytic samples from a lamp or solar simulator light source. The reactor has a volume of only 3.80 ml allowing for the investigation of very small quantities of a catalytic material, down to 1 mg. The stainless steel construction allows the cell to be heated to 350 °C and can withstand pressures up to 27 bar, limited only by the sapphire window. High-pressure sampling is made possible by a computer controlled pulsed valve that delivers precise gas flow, enabling catalytic reactions to be monitored across a wide range of pressures. A residual gas analyser mass spectrometer forms a part of the detection system, which is able to provide a rapid, real-time analysis of the gas composition within the photocatalytic reaction chamber. This apparatus is ideal for investigating a number of industrially relevant reactions including photocatalytic water splitting and CO 2 reduction. Initial catalytic results using Pt-doped and Ru nanoparticle-doped TiO 2 as benchmark experiments are presented.
Screening mail for powders using terahertz technology
NASA Astrophysics Data System (ADS)
Kemp, Mike
2011-11-01
Following the 2001 Anthrax letter attacks in the USA, there has been a continuing interest in techniques that can detect or identify so-called 'white powder' concealed in envelopes. Electromagnetic waves (wavelengths 100-500 μm) in the terahertz frequency range penetrate paper and have short enough wavelengths to provide good resolution images; some materials also have spectroscopic signatures in the terahertz region. We report on an experimental study into the use of terahertz imaging and spectroscopy for mail screening. Spectroscopic signatures of target powders were measured and, using a specially designed test rig, a number of imaging methods based on reflection, transmission and scattering were investigated. It was found that, contrary to some previous reports, bacterial spores do not appear to have any strong spectroscopic signatures which would enable them to be identified. Imaging techniques based on reflection imaging and scattering are ineffective in this application, due to the similarities in optical properties between powders of interest and paper. However, transmission imaging using time-of-flight of terahertz pulses was found to be a very simple and sensitive method of detecting small quantities (25 mg) of powder, even in quite thick envelopes. An initial feasibility study indicates that this method could be used as the basis of a practical mail screening system.
NASA Technical Reports Server (NTRS)
Takeuchi, Yoshimi R.; Frantz, Peter P.; Hilton, Michael R.
2014-01-01
The performance and life of precision ball bearings are critically dependent on maintaining a quantity of oil at the ball/race interface that is sufficient to support a robust protective film. In space applications, where parched conditions are intentionally the norm, harsh operating conditions can displace the small reserves of oil, resulting in reduced film thickness and premature wear. In the past, these effects have proven difficult to model or to measure experimentally. This paper describes a study addressing this challenge, where bearing thermal conductance measurements are employed to infer changes in lubricant quantity at the critical rolling interfaces. In the first part of the paper, we explain how the lubricant's presence and its quantity impacts bearing thermal conductance measurements. For a stationary bearing, we show that conductance is directly related to the lubricant quantity in the ball/race contacts. Hence, aspects of bearing performance related to oil quantity can be understood and insights improved with thermal conductance data. For a moving bearing, a different mechanism of heat transfer dominates and is dependent on lubricant film thickness on the ball. In the second part of the report, we discuss lubricant quantity observations based on bearing thermal conductance measurements. Lubricant quantity, and thus bearing thermal conductance, depends on various initial and operating conditions and is impacted further by the run-in process. A significant effect of maximum run-in speed was also observed, with less oil remaining after obtaining higher speeds. Finally, we show that some of the lubricant that is displaced between the ball and race during run-in operation can be recovered during rest, and we measure the rate of recovery for one example.
Continuous information flow fluctuations
NASA Astrophysics Data System (ADS)
Rosinberg, Martin Luc; Horowitz, Jordan M.
2016-10-01
Information plays a pivotal role in the thermodynamics of nonequilibrium processes with feedback. However, much remains to be learned about the nature of information fluctuations in small-scale devices and their relation with fluctuations in other thermodynamics quantities, like heat and work. Here we derive a series of fluctuation theorems for information flow and partial entropy production in a Brownian particle model of feedback cooling and extend them to arbitrary driven diffusion processes. We then analyze the long-time behavior of the feedback-cooling model in detail. Our results provide insights into the structure and origin of large deviations of information and thermodynamic quantities in autonomous Maxwell's demons.
Formation of hydrogen peroxide in the silver reductor: A micro-analytical method for iron
Fryling, C.F.; Tooley, F.V.
1936-01-01
1. An attempt to determine small quantities of iron by reduction with silver followed by titration with eerie sulfate revealed an error attributable to the formation of hydrogen peroxide in the reductor. 2. By conducting the reduction in an atmosphere of hydrogen, thereby decreasing the reductor correction, and applying a correction for the indicator, it was possible to determine quantities of iron of the order of 1.5 mg. with a high degree of accuracy. 3. The method was found to be relatively rapid and not to require the use of large platinum dishes, thus possessing advantages of practical value.
Indrasena, W M; Ackman, R G; Gill, T A
1999-09-10
Thin-layer chromatography (TLC) on Chromarods-SIII with the Iatroscan (Mark-5) and a flame thermionic detector (FTID) was used to develop a rapid method for the detection of paralytic shellfish poisoning (PSP) toxins. The effect of variation in hydrogen (H2) flow, air flow, scan time and detector current on the FTID peak response for both phosphatidylcholine (PC) and PSP were studied in order to define optimum detection conditions. A combination of hydrogen and air flow-rates of 50 ml/min and 1.5-2.0 l/min respectively, along with a scan time of 40 s/rod and detector current of 3.0 A (ampere) or above were found to yield the best results for the detection of PSP compounds. Increasing the detector current level to as high as 3.3 A gave about 130 times more FTID response than did flame ionization detection (FID), for PSP components. Quantities of standards as small as 1 ng neosaxitoxin (NEO), 5 ng saxitoxin (STX), 5 ng B1-toxins (B1), 2 ng gonyautoxin (GTX) 2/3, 6 ng GTX 1/4 and 6 ng C-toxins (C1/C2) could be detected with the FTID. The method detection limits for toxic shellfish tissues using the FTID were 0.4, 2.1, 0.8 and 2.5 micrograms per g tissue for GTX 2/3, STX, NEO and C toxins, respectively. The FTID response increased with increasing detector current and with increasing the scan time. Increasing hydrogen and air flow-rates resulted in decreasing sensitivity within defined limits. Numerous solvent systems were tested, and, solvent consisting of chloroform: methanol-water-acetic acid (30:50:8:2) could separate C toxins from GTX, which eluted ahead of NEO and STX. Accordingly, TLC/FTID with the Iatroscan (Mark-5) seems to be a promising, relatively inexpensive and rapid method of screening plant and animal tissues for PSP toxins.
Boehme, Philip; Stellberger, Thorsten; Solanki, Manish; Zhang, Wenli; Schulz, Eric; Bergmann, Thorsten; Liu, Jing; Doerner, Johannes; Baiker, Armin E.
2015-01-01
Abstract High-capacity adenoviral vectors (HCAdVs) are promising tools for gene therapy as well as for genetic engineering. However, one limitation of the HCAdV vector system is the complex, time-consuming, and labor-intensive production process and the following quality control procedure. Since HCAdVs are deleted for all viral coding sequences, a helper virus (HV) is needed in the production process to provide the sequences for all viral proteins in trans. For the purification procedure of HCAdV, cesium chloride density gradient centrifugation is usually performed followed by buffer exchange using dialysis or comparable methods. However, performing these steps is technically difficult, potentially error-prone, and not scalable. Here, we establish a new protocol for small-scale production of HCAdV based on commercially available adenovirus purification systems and a standard method for the quality control of final HCAdV preparations. For titration of final vector preparations, we established a droplet digital polymerase chain reaction (ddPCR) that uses a standard free-end-point PCR in small droplets of defined volume. By using different probes, this method is capable of detecting and quantifying HCAdV and HV in one reaction independent of reference material, rendering this method attractive for accurately comparing viral titers between different laboratories. In summary, we demonstrate that it is possible to produce HCAdV in a small scale of sufficient quality and quantity to perform experiments in cell culture, and we established a reliable protocol for vector titration based on ddPCR. Our method significantly reduces time and required equipment to perform HCAdV production. In the future the ddPCR technology could be advantageous for titration of other viral vectors commonly used in gene therapy. PMID:25640117
Horn, Patricia; Schlichting, André; Baum, Christel; Hammesfahr, Ute; Thiele-Bruhn, Sören; Leinweber, Peter; Broer, Inge
2017-09-10
We introduce an easy, fast and effective method to analyze the influence of genetically modified (GM) plants on soil and model organisms in the laboratory to substitute laborious and time consuming field trials. For the studies described here we focused on two GM plants of the so-called 3rd generation: GM plants producing pharmaceuticals (PMP) and plant made industrials (PMI). Cyanophycin synthetase (cphA) was chosen as model for PMI and Choleratoxin B (CTB) as model for PMP. The model genes are expressed in transgenic roots of composite Vicia hirsuta plants grown in petri dishes for semi-sterile growth or small containers filled with non-sterile soil. No significant influence of the model gene expression on root induction, growth, biomass, interaction with symbionts such as rhizobia (number, size and functionality of nodules, selection of nodulating strains) or arbuscular mycorrhizal fungi could be detected. In vitro, but not in situ under field conditions, structural diversity of the bulk soil microbial community between transgenic and non-transgenic cultivars was determined by PLFA pattern-derived ratios of bacteria: fungi and of gram + : gram - bacteria. Significant differences in PLFA ratios were associated with dissimilarities in the quantity and molecular composition of rhizodeposits as revealed by Py-FIMS analyses. Contrary to field trials, where small effects based on the transgene expression might be hidden by the immense influence of various environmental factors, our in vitro system can detect even minor effects and correlates them to transgene expression with less space, time and labour. Copyright © 2016 Elsevier B.V. All rights reserved.
Chlamydia and gonorrhoea contamination of clinic surfaces.
Lewis, Natasha; Dube, Gail; Carter, Christine; Pitt, Rachel; Alexander, Sarah; Ison, Catherine A; Harding, Jan; Brown, Louise; Fryer, John; Hodson, James; Ross, Jonathan
2012-10-01
Nucleic acid amplification tests, with their ability to detect very small amounts of nucleic acid, have become the principle diagnostic tests for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) in many sexual health clinics. The aim of this study was to investigate the extent of surface contamination with CT and GC within a city centre sexual health clinic and to evaluate the potential for contamination of containers used for the collection of self-taken swabs. Surface contamination with CT and GC was assessed by systematically sampling 154 different sites within one clinic using transcription-mediated amplification (TMA), quantitative PCR and culture. The caps of containers used by patients to collect self-taken samples were also tested for CT and GC using TMA. Of the 154 sites sampled, 20 (13.0%) tested positive on TMA. Of these, five (3.2%) were positive for CT alone, 11 (7.1%) for GC alone and four (2.6%) for both CT and GC. The proportion of GC TMA-positive test results differed by gender, with 11 (18.3%) positive results from the male patient clinic area compared with one (1.6%) from the female area (p=0.002). Positive samples were obtained from a variety of locations in the clinic, but the patient toilets were more likely to be contaminated than examination rooms (p=0.015). Quantitative PCR and culture assays were negative for all samples. 46 caps of the containers used for self-taken swabs were negative for both CT and GC on TMA testing. Surface contamination with chlamydial and gonococcal rRNA can occur within sexual health clinics, but the quantity of nucleic acid detected is low and infection risk to patients and staff is small. There remains a potential risk of contamination of patient samples leading to false-positive results.
Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events
NASA Astrophysics Data System (ADS)
Gillam, John E.; Solevi, Paola; Oliver, Josep F.; Casella, Chiara; Heller, Matthieu; Joram, Christian; Rafecas, Magdalena
2014-08-01
The development of novel detection devices and systems such as the AX-positron emission tomography (PET) demonstrator often introduce or increase the measurement of atypical coincidence events such as inter-crystal scattering (ICS). In more standard systems, ICS events often go undetected and the small measured fraction may be ignored. As the measured quantity of such events in the data increases, so too does the importance of considering them during image reconstruction. Generally, treatment of ICS events will attempt to determine which of the possible candidate lines of response (LoRs) correctly determine the annihilation photon trajectory. However, methods of assessment often have low success rates or are computationally demanding. In this investigation alternative approaches are considered. Experimental data was taken using the AX-PET prototype and a NEMA phantom. Three methods of ICS treatment were assessed—each of which considered all possible candidate LoRs during image reconstruction. Maximum likelihood expectation maximization was used in conjunction with both standard (line-like) and novel (V-like in this investigation) detection responses modeled within the system matrix. The investigation assumed that no information other than interaction locations was available to distinguish between candidates, yet the methods assessed all provided means by which such information could be included. In all cases it was shown that the signal to noise ratio is increased using ICS events. However, only one method, which used full modeling of the ICS response in the system matrix—the V-like model—provided enhancement in all figures of merit assessed in this investigation. Finally, the optimal method of ICS incorporation was demonstrated using data from two small animals measured using the AX-PET demonstrator.
Bluth, G.J.S.; Casadevall, T.J.; Schnetzler, C.C.; Doiron, S.D.; Walter, Louis S.; Krueger, A.J.; Badruddin, M.
1994-01-01
Galunggung volcano, Java, awoke from a 63-year quiescence in April 1982, and erupted sporadically through January 1983. During its most violent period from April to October, the Cikasasah Volcano Observatory reported 32 large and 56 moderate to small eruptions. From April 5 through September 19 the Total Ozone Mapping Spectrometer (TOMS), carried on NASA's Nimbus-7 satellite, detected and measured 24 different sulfur dioxide clouds; an estimated 1730 kilotons (kt) of SO2 were outgassed by these explosive eruptions. The trajectories, and rapid dispersion rates, of the SO2 clouds were consistent with injection altitudes below the tropopause. An additional 300 kt of SO2 were estimated to have come from 64 smaller explosive eruptions, based on the detection limit of the TOMS instrument. For the first time, an extended period of volcanic activity was monitored by remote sensing techniques which enabled observations of both the entire SO2 clouds produced by large explosive eruptions (using TOMS), and the relatively lower levels of SO2 emissions during non-explosive outgassing (using the Correlation Spectrometer, or COSPEC). Based on COSPEC measurements from August 1982 to January 1983, and on the relationship between explosive and non-explosive degassing, approximately 400 kt of SO2 were emitted during non-explosive activity. The total sulfur dioxide outgassed from Galunggung volcano from April 1982 to January 1983 is calculated to be 2500 kt (?? 30%) from both explosive and non-explosive activity. While Galunggung added large quantities of sulfur dioxide to the atmosphere, its sporadic emissions occurred in relatively small events distributed over several months, and reached relatively low altitudes, and are unlikely to have significantly affected aerosol loading of the stratosphere in 1982 by volcanic activity. ?? 1994.
Branco, Luis M; Grove, Jessica N; Geske, Frederick J; Boisen, Matt L; Muncy, Ivana J; Magliato, Susan A; Henderson, Lee A; Schoepp, Randal J; Cashman, Kathleen A; Hensley, Lisa E; Garry, Robert F
2010-10-20
Lassa fever is a neglected tropical disease with significant impact on the health care system, society, and economy of Western and Central African nations where it is endemic. Treatment of acute Lassa fever infections has successfully utilized intravenous administration of ribavirin, a nucleotide analogue drug, but this is not an approved use; efficacy of oral administration has not been demonstrated. To date, several potential new vaccine platforms have been explored, but none have progressed toward clinical trials and commercialization. Therefore, the development of a robust vaccine platform that could be generated in sufficient quantities and at a low cost per dose could herald a subcontinent-wide vaccination program. This would move Lassa endemic areas toward the control and reduction of major outbreaks and endemic infections. To this end, we have employed efficient mammalian expression systems to generate a Lassa virus (LASV)-like particle (VLP)-based modular vaccine platform. A mammalian expression system that generated large quantities of LASV VLP in human cells at small scale settings was developed. These VLP contained the major immunological determinants of the virus: glycoprotein complex, nucleoprotein, and Z matrix protein, with known post-translational modifications. The viral proteins packaged into LASV VLP were characterized, including glycosylation profiles of glycoprotein subunits GP1 and GP2, and structural compartmentalization of each polypeptide. The host cell protein component of LASV VLP was also partially analyzed, namely glycoprotein incorporation, though the identity of these proteins remain unknown. All combinations of LASV Z, GPC, and NP proteins that generated VLP did not incorporate host cell ribosomes, a known component of native arenaviral particles, despite detection of small RNA species packaged into pseudoparticles. Although VLP did not contain the same host cell components as the native virion, electron microscopy analysis demonstrated that LASV VLP appeared structurally similar to native virions, with pleiomorphic distribution in size and shape. LASV VLP that displayed GPC or GPC+NP were immunogenic in mice, and generated a significant IgG response to individual viral proteins over the course of three immunizations, in the absence of adjuvants. Furthermore, sera from convalescent Lassa fever patients recognized VLP in ELISA format, thus affirming the presence of native epitopes displayed by the recombinant pseudoparticles. These results established that modular LASV VLP can be generated displaying high levels of immunogenic viral proteins, and that small laboratory scale mammalian expression systems are capable of producing multi-milligram quantities of pseudoparticles. These VLP are structurally and morphologically similar to native LASV virions, but lack replicative functions, and thus can be safely generated in low biosafety level settings. LASV VLP were immunogenic in mice in the absence of adjuvants, with mature IgG responses developing within a few weeks after the first immunization. These studies highlight the relevance of a VLP platform for designing an optimal vaccine candidate against Lassa hemorrhagic fever, and warrant further investigation in lethal challenge animal models to establish their protective potential.
103P/Hartley 2: ground-based monitoring of the EPOXI flyby comet
NASA Astrophysics Data System (ADS)
Tubiana, C.; Snodgrass, C.; Vincent, J.-B.; Barrera, L.; Nowajewski, P.; Retamales, G.; Lister, T.; Boehnhardt, H.
2011-10-01
Comet 103P/Hartley 2 was the fly-by target of the NASA EPOXI mission. Observations of this comet during its previous perihelion passage [1] and in 2008 when it was in its aphelion arc [2, 3] revealed a small and very active nucleus. We observed 103P from March 2010 to January 2011 using the 4m SOAR telescope located at Cerro Pachon, Chile. We took images in UBVRI filters using the SOAR Optical Imager (SOI). In addition, we made use of the large collection of (mostly BVR) images taken of the comet by school pupils using the two robotic 2m Faulkes Telescopes, which cover the same period. At the time of the observations, the comet was moving from 2.8 AU pre-perihelion to 1.6 AU post-perihelion heliocentric distance, when the comet was expected to display the most activity. The main purpose of our observations was the characterization of the activity of comet 103P and its evolution along the perihelion arc. We searched for the presence of dust coma structures and their evolution with changing heliocentric distance and determined gas and dust production rates, the dust color and the variation in these quantities as the comet passed perihelion. While no coma structures were detected between March and July 2010, a clear anisotropy in the coma in the anti-tail direction was detected in images obtained in November 2011 (Fig. 1). At the same place, the Laplace filter detects what might be a jet.
Large area robust identification of snow cover from multitemporal COSMO-SkyMed images
NASA Astrophysics Data System (ADS)
Pettinato, S.; Santi, E.; Paloscia, S.; Aiazzi, B.; Baronti, S.; Palchetti, E.; Garzelli, A.
2015-10-01
This paper investigates the ability of the Information Theoretic Snow Detection Algorithm (ITSDA) in detecting changes due to snow cover between summer and winter seasons on large area images acquired by COSMO-SkyMed constellation. ITSDA is a method for change detection in multitemporal SAR images, which has been recently applied by the authors to a subset of Cosmo-SkyMed data. The proposed technique is based on a nonparametric approach in the framework of Shannon's information theory, and in particular it features the conditional probability of the local means between the two images taken at different times. Such an unsupervised approach does not require any preliminary despeckling procedure to be performed before the calculation of the change map. In the case of a low quantity of anomalous changes in relatively small-size images, a mean shift procedure can be utilized for refining the map. However, in the present investigation, the changes to be identified are pervasive in large size images. Consequently, for computational issues, the mean shift refinement has been omitted in the present work. However, a simplified implementation of mean shift procedure to save time will be possibly considered in future submissions. In any case, the present version of ITSDA method preserve its characteristics of flexibility and sensibility to backscattering changes, thanks to the possibility of setting up the number of quantization levels in the estimation of the conditional probability between the amplitude values at the two acquisition dates.
Moreno, Ivo; Barroso, Mário; Martinho, Ana; Cruz, Angelines; Gallardo, Eugenia
2015-11-01
Ketamine is a club drug widely abused for its hallucinogenic effects, being also used as a "date-rape" drug in recent years. We have developed an analytical method using gas chromatography-tandem mass spectrometry (GC-MS/MS) for the identification and quantification of ketamine and its major metabolite in urine and plasma. No derivatization step is needed to accomplish analysis. The compounds were extracted from 0.25mL of sample using microextraction by packed sorbent on mixed mode (M1) cartridges. Calibration curves were linear in the range of 10-250ng/mL for urine and 10-500ng/mL for plasma, with determination coefficients higher than 0.99. The limit of detection (LOD) was 5ng/mL for both compounds in both specimens. Recoveries ranged from 63 to 101%, while precision and accuracy were below 14% and 15%, respectively. These low limits of detection and the quite high recoveries obtained, in very low sample amounts, allow detecting small quantities of the compounds, making this procedure suitable for those laboratories performing routine analysis in the field of forensic toxicology. Compared with existing methods, the herein described procedure is fast, since no derivatization step is required, and cost effective for the quantification of ketamine and norketamine in biological specimens by gas chromatography. Copyright © 2015 Elsevier B.V. All rights reserved.