Zarubina, Anna V.; Neely, David C.; Clark, Mark E.; Huisingh, Carrie E.; Samuels, Brian C.; Zhang, Yuhua; McGwin, Gerald; Owsley, Cynthia; Curcio, Christine A.
2015-01-01
Purpose To assess the prevalence of subretinal drusenoid deposits (SDD) in older adults with healthy maculas and early and intermediate age-related macular degeneration (AMD) using multimodal imaging. Design Cross-sectional study. Participants A total of 651 subjects aged ≥60 years enrolled in the Alabama Study of Early Age-Related Macular Degeneration from primary care ophthalmology clinics. Methods Subjects were imaged using spectral domain optical coherence tomography (SD-OCT) of the macula and optic nerve head (ONH), infrared reflectance, fundus autofluorescence, and color fundus photographs (CFP). Eyes were assessed for AMD presence and severity using the AREDS 9-step scale. Criteria for SDD presence were identification on ≥1 en-face modality plus SD-OCT or on ≥2 en-face modalities if absent on SD-OCT. SDD were considered present at the person-level if present in 1 or both eyes. Main outcomes measures Prevalence of SDD in participants with and without AMD. Results Overall prevalence of SDD was 32% (197/611), with 62% (122/197) affected in both eyes. Persons with SDD were older than those without SDD (70.6 vs. 68.7 years, p =0.0002). Prevalence of SDD was 23% in subjects without AMD and 52% in subjects with AMD (p<0.0001). Among those with early and intermediate AMD, SDD prevalence was 49% and 79%, respectively. After age adjustment, those with SDD were 3.4x more likely to have AMD than those without SDD (95% CI 2.3–4.9). By using CFP only for SDD detection per the AREDS protocol, prevalence of SDD was 2% (12/610). Of persons with SDD detected by SD-OCT and confirmed by at least one en-face modality 47% (89/190) were detected exclusively on the ONH SD-OCT volume. Conclusion SDD are present in approximately one quarter of older adults with healthy maculae and in more than half of persons with early to intermediate AMD, even by stringent criteria. The prevalence of SDD is strongly associated with AMD presence and severity and increases with age, and its retinal topography including peripapillary involvement resembles that of rod photoreceptors. Consensus on SDD detection methods is recommended to advance our knowledge of this lesion and its clinical and biologic significance. PMID:26875000
Zarubina, Anna V; Neely, David C; Clark, Mark E; Huisingh, Carrie E; Samuels, Brian C; Zhang, Yuhua; McGwin, Gerald; Owsley, Cynthia; Curcio, Christine A
2016-05-01
To assess the prevalence of subretinal drusenoid deposits (SDD) in older adults with healthy maculas and early and intermediate age-related macular degeneration (AMD) using multimodal imaging. Cross-sectional study. A total of 651 subjects aged ≥60 years enrolled in the Alabama Study of Early Age-Related Macular Degeneration from primary care ophthalmology clinics. Subjects were imaged using spectral domain optical coherence tomography (SD OCT) of the macula and optic nerve head (ONH), infrared reflectance, fundus autofluorescence, and color fundus photographs (CFP). Eyes were assessed for AMD presence and severity using the Age-Related Eye Disease Study (AREDS) 9-step scale. Criteria for SDD presence were identification on ≥1 en face modality plus SD OCT or on ≥2 en face modalities if absent on SD OCT. Subretinal drusenoid deposits were considered present at the person level if present in 1 or both eyes. Prevalence of SDD in participants with and without AMD. Overall prevalence of SDD was 32% (197/611), with 62% (122/197) affected in both eyes. Persons with SDD were older than those without SDD (70.6 vs. 68.7 years, P = 0.0002). Prevalence of SDD was 23% in subjects without AMD and 52% in subjects with AMD (P < 0.0001). Among those with early and intermediate AMD, SDD prevalence was 49% and 79%, respectively. After age adjustment, those with SDD were 3.4 times more likely to have AMD than those without SDD (95% confidence interval, 2.3-4.9). By using CFP only for SDD detection per the AREDS protocol, prevalence of SDD was 2% (12/610). Of persons with SDD detected by SD OCT and confirmed by at least 1 en face modality, 47% (89/190) were detected exclusively on the ONH SD OCT volume. Subretinal drusenoid deposits are present in approximately one quarter of older adults with healthy maculae and in more than half of persons with early to intermediate AMD, even by stringent criteria. The prevalence of SDD is strongly associated with AMD presence and severity and increases with age, and its retinal topography including peripapillary involvement resembles that of rod photoreceptors. Consensus on SDD detection methods is recommended to advance our knowledge of this lesion and its clinical and biologic significance. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Plant height revertants of Dominant Semidwarf mutant rice created by low-energy ion irradiation
NASA Astrophysics Data System (ADS)
Liu, Binmei; Wu, Yuejin; Xu, Xue; Song, M.; Zhao, M.; Fu, X. D.
2008-04-01
Dominant Semidwarf mutant rice (Sdd) was obtained from its wild type (WT) by irradiation with a low-energy ion beam. Six tall revertants of Sdd were induced by irradiation. The revertants restored the plant height to that of WT plants. Investigation of the agronomic character and genetic analysis indicate that the revertants are similar to WT plants with putative different inherited mutations. The revertants were checked for DNA differences using the simple sequence repeat technique. Among 408 such primers used, only 2 primers detected mutation sites in the revertants, which provided the molecular evidence for the revertants induced from Sdd. This study indicates that ion irradiation may be used as a mutagen to create revertants for plant architecture studies and could be a new application.
Hanna-Addams, Sarah; Wang, Zhigao
2018-04-26
Amyloid or amyloid-like fibers have been associated with many human diseases, and are now being discovered to be important for many signaling pathways. The ability to readily detect the formation of these fibers under various experimental conditions is essential for understanding their potential function. Many methods have been used to detect the fibers, but not without some drawbacks. For example, electron microscopy (EM), or staining with Congo Red or Thioflavin T often requires purification of the fibers. On the other hand, semi-denaturing detergent agarose gel electrophoresis (SDD-AGE) allows detection of the SDS-resistant amyloid-like fibers in the cell extracts without purification. In addition, it allows the comparison of the size difference of the fibers. More importantly, it can be used to identify specific proteins within the fibers by Western blotting. It is less time consuming and more easily accessible to a wider number of labs. SDD-AGE results often show variable degree of heterogeneity. It raises the question whether part of the heterogeneity results from the dissociation of the protein complex during the electrophoresis in the presence of SDS. For this reason, we have employed a second dimension of SDD-AGE to determine if the size heterogeneity seen in SDD-AGE is truly a result of fiber heterogeneity in vivo and not a result of either degradation or dissociation of some of the proteins during electrophoresis. This method allows fast, qualitative confirmation that the amyloid or amyloid-like fibers are not partially dissociating during the SDD-AGE process.
Sawa, Hidehiro; Ueda, Takashi; Takeyama, Yoshifumi; Yasuda, Takeo; Shinzeki, Makoto; Matsumura, Naoki; Nakajima, Takahiro; Matsumoto, Ippei; Fujita, Tsunenori; Ajiki, Tetsuo; Fujino, Yasuhiro; Kuroda, Yoshikazu
2007-01-01
Sepsis due to infected pancreatic necrosis is the most serious complication in the late phase of severe acute pancreatitis (SAP). Bacterial translocation from the gut is thought to be the main cause of pancreatic infection. The possibility has recently been reported that selective digestive decontamination (SDD) and enteral nutrition (EN) may alleviate the complications and reduce the mortality rate in patients with SAP. We analyzed the treatment outcome of SDD and EN in patients with SAP. We divided 90 patients with SAP into three groups: SDD(-)EN(-),group A; SDD(+)EN(-), group B; and SDD(+)EN(+), group C. Clinical outcome was analyzed retrospectively. The effect of SDD was compared in groups A and B, and the effect of EN was compared in groups B and C. The background of patients was not significantly different between the groups. SDD reduced the incidence of organ dysfunction (from 70% to 59%) and the mortality rate (from 40% to 28%), but the differences were not significant. EN reduced the incidence of infected pancreatic necrosis (from 31% to 24%) and the frequency of surgery for pancreas (from 28% to 18%), and further reduced the mortality rate (from 28% for SDD to 16%), but the differences were not significant. The peripheral lymphocyte count was significantly increased in patients with EN. SDD and EN did not significantly affect the treatment outcome in SAP. However, the results in this study raise the possibility that SDD and EN may decrease the complications and reduce the mortality rate in SAP. The efficacy of SDD and EN for SAP should be evaluated in a randomized controlled trial.
Subantimicrobial dose doxycycline effects on osteopenic bone loss: microbiologic results.
Walker, Clay; Puumala, Susan; Golub, Lorne M; Stoner, Julie A; Reinhardt, Richard A; Lee, Hsi-Ming; Payne, Jeffrey B
2007-08-01
Based on microbiologic concerns, the safety of a 24-month regimen of subantimicrobial dose doxycycline (SDD; 20 mg twice a day) was evaluated in postmenopausal osteopenic women with periodontitis in a double-blind, placebo-controlled, randomized clinical trial. Subgingival samples were collected from two sites (probing depth > or = 5 mm) in each of 128 subjects at baseline, with the same sites resampled at the conclusion of the 2-year period. The samples were enumerated on selective and non-selective media and on doxycycline (4 microg/ml) medium. Up to five different colonial morphologies were subcultured from the doxycycline medium, identified to species, and susceptibilities determined to doxycycline and five other antibiotics. Data were analyzed for microbial differences in total colony forming units (CFU), periodontal and opportunistic pathogens, and changes in species and in susceptibilities of isolates recovered on doxycycline medium. There was no significant evidence that changes in total anaerobic counts over the treatment period (P = 0.96) differed between treatment groups. Likewise, periodontal pathogens, opportunistic pathogens, or normal flora did not differ descriptively between groups. Although there was a significant increase (P <0.001) in the total CFU recovered from the 4 microg/ml doxycycline plates at 24 months for SDD versus placebo, the percentage that was clinically resistant to doxycycline (minimal inhibitory concentration [MIC] > or = 16 microg/ml) decreased over the 24-month period in both groups and did not differ between the treatment groups (SDD: 79% to 76%; placebo: 83% to 70%; P = 0.2). There were no significant differences (P >0.28 for each) in the change in cross-resistance between the groups for doxycycline and the other five antibiotics. No antimicrobial effect on the subgingival flora was detected following treatment with SDD for 24 months, relative to baseline or to placebo. The increase in initial resistance (at 4 microg/ml) did not translate into a significant increase in the percent resistant to doxycycline (MIC > or = 16 microg/ml) for patients in the SDD group.
Emre, S; Sebastian, A; Chodoff, L; Boccagni, P; Meyers, B; Sheiner, P A; Mor, E; Guy, S R; Atillasoy, E; Schwartz, M E; Miller, C M
1999-01-01
In liver transplant (LTx) recipients, gut-associated bacterial and fungal organisms produce significant postoperative morbidity and mortality. We sought to assess the role of selective digestive decontamination (SDD) in preventing postoperative infections in a large single-center cohort of liver recipients transplanted under two non-simultaneous protocols. In 212 consecutive patients transplanted between 1/1/91 and 7/31/92, SDD (gentamicin 80 mg, polymyxin B 100 mg, nystatin suspension 10 mL) was employed, starting after induction of anesthesia and continued until POD 21 (SDD Group). In 157 consecutive patients transplanted between 1/1/93 and 12/31/93, SDD was not used (non-SDD Group). Both groups received IV vancomycin and cefotaxime prophylaxis. All culture-positive infections within the first 30 days post-LTx were recorded and classified as bacterial or fungal. Infection-related mortality (patients who died of infectious complications without any technical complication) was recorded. Groups did not differ in patient demographics, United Network for Organ Sharing (UNOS) status, use of veno-venous bypass, total/warm ischemia, or length of ICU stay. Infections developed in fewer SDD patients (56/212; 26%) than non-SDD patients (69/157; 44%) (p<0.001). The incidence of gram-negative infection was less in the SDD group (11% vs. 26%, p<0. 001) as was gram-positive infection (16% vs. 26%, p<0.001). Among patients who developed infection, there was no difference between groups in infections per patient. Primary graft non-function (PNF) developed in 20 SDD patients (7/20 had infections) and 8 non-SDD patients (6/8 had infections) (p=0.06). There were no differences in incidence of fungal infections or of infection-related mortality between groups. In the SDD group, there were fewer abdominal (p<0. 001), lung (p<0.001), wound (p<0.01), and urinary tract infections (p<0.05). Use of SDD in liver recipients early after transplant was associated with significantly fewer infections in the early postoperative period.
Ichikawa, Shota; Kamishima, Tamotsu; Sutherland, Kenneth; Fukae, Jun; Katayama, Kou; Aoki, Yuko; Okubo, Takanobu; Okino, Taichi; Kaneda, Takahiko; Takagi, Satoshi; Tanimura, Kazuhide
2017-10-01
We have developed a refined computer-based method to detect joint space narrowing (JSN) progression with the joint space narrowing progression index (JSNPI) by superimposing sequential hand radiographs. The purpose of this study is to assess the validity of a computer-based method using images obtained from multiple institutions in rheumatoid arthritis (RA) patients. Sequential hand radiographs of 42 patients (37 females and 5 males) with RA from two institutions were analyzed by a computer-based method and visual scoring systems as a standard of reference. The JSNPI above the smallest detectable difference (SDD) defined JSN progression on the joint level. The sensitivity and specificity of the computer-based method for JSN progression was calculated using the SDD and a receiver operating characteristic (ROC) curve. Out of 314 metacarpophalangeal joints, 34 joints progressed based on the SDD, while 11 joints widened. Twenty-one joints progressed in the computer-based method, 11 joints in the scoring systems, and 13 joints in both methods. Based on the SDD, we found lower sensitivity and higher specificity with 54.2 and 92.8%, respectively. At the most discriminant cutoff point according to the ROC curve, the sensitivity and specificity was 70.8 and 81.7%, respectively. The proposed computer-based method provides quantitative measurement of JSN progression using sequential hand radiographs and may be a useful tool in follow-up assessment of joint damage in RA patients.
Hemke, Robert; Tzaribachev, Nikolay; Nusman, Charlotte M; van Rossum, Marion A J; Maas, Mario; Doria, Andrea S
2017-08-01
There is increasing evidence that early therapeutic intervention improves longterm joint outcome in juvenile idiopathic arthritis (JIA). Given the existence of highly effective treatments, there is an urgent need for reliable and accurate measures of disease activity and joint damage in JIA. Our objective was to assess the reliability of 2 magnetic resonance imaging (MRI) scoring methods: the Juvenile Arthritis MRI Scoring (JAMRIS) system and the International Prophylaxis Study Group (IPSG) consensus score, for evaluating disease status of the knee in patients with JIA. Four international readers independently scored an MRI dataset of 25 JIA patients with clinical knee involvement. Synovial thickening, joint effusion, bone marrow changes, cartilage lesions, bone erosions, and subchondral cysts were scored using the JAMRIS and IPSG systems. Further, synovial enhancement, infrapatellar fat pad heterogeneity, tendinopathy, and enthesopathy were scored. Interreader reliability was analyzed by using the generalized κ, ICC, and the smallest detectable difference (SDD). ICC regarding interreader reliability ranged from 0.33 (95% CI 0.12-0.52, SDD = 0.29) for enthesopathy up to 0.95 (95% CI 0.92-0.97, SDD = 3.19) for synovial thickening. Good interreader reliability was found concerning joint effusion (ICC 0.93, 95% CI 0.89-0.95, SDD = 0.51), synovial enhancement (ICC 0.90, 95% CI 0.85-0.94, SDD = 9.85), and bone marrow changes (ICC 0.87, 95% CI 0.80-0.92, SDD = 10.94). Moderate to substantial reliability was found concerning cartilage lesions and bone erosions (ICC 0.55-0.72, SDD 1.41-13.65). The preliminary results are promising for most of the scored JAMRIS and IPSG items. However, further refinement of the scoring system is warranted for unsatisfactorily reliable items such as bone erosions, cartilage lesions, and enthesopathy.
Selective decontamination of the digestive tract reduces pneumonia and mortality.
Haas, Lenneke E M; Schultz, Marcus J
2010-01-01
Selective decontamination of the digestive tract (SDD) has been subject of numerous randomized controlled trials in critically ill patients. Almost all clinical trials showed SDD to prevent pneumonia. Nevertheless, SDD has remained a controversial strategy. One reason for why clinicians remained reluctant to implement SDD into daily practice could be that mortality was reduced in only 2 trials. Another reason could be the heterogeneity of trials of SDD. Indeed, many different prophylactic antimicrobial regimes were tested, and dissimilar diagnostic criteria for pneumonia were applied amongst the trials. This heterogeneity impeded interpretation and comparison of trial results. Two other hampering factors for implementation of SDD have been concerns over the risk of antimicrobial resistance and fear for escalation of costs associated with the use of prophylactic antimicrobials. This paper describes the concept of SDD, summarizes the results of published trials of SDD in mixed medical-surgical intensive care units, and rationalizes the risk of antimicrobial resistance and rise of costs associated with this potentially life-saving preventive strategy.
Daneman, Nick; Sarwar, Syed; Fowler, Robert A; Cuthbertson, Brian H
2013-04-01
Many meta-analyses have shown reductions in infection rates and mortality associated with the use of selective digestive decontamination (SDD) or selective oropharyngeal decontamination (SOD) in intensive care units (ICUs). These interventions have not been widely implemented because of concerns that their use could lead to the development of antimicrobial resistance in pathogens. We aimed to assess the effect of SDD and SOD on antimicrobial resistance rates in patients in ICUs. We did a systematic review of the effect of SDD and SOD on the rates of colonisation or infection with antimicrobial-resistant pathogens in patients who were critically ill. We searched for studies using Medline, Embase, and Cochrane databases, with no limits by language, date of publication, study design, or study quality. We included all studies of selective decontamination that involved prophylactic application of topical non-absorbable antimicrobials to the stomach or oropharynx of patients in ICUs, with or without additional systemic antimicrobials. We excluded studies of interventions that used only antiseptic or biocide agents such as chlorhexidine, unless antimicrobials were also included in the regimen. We used the Mantel-Haenszel model with random effects to calculate pooled odds ratios. We analysed 64 unique studies of SDD and SOD in ICUs, of which 47 were randomised controlled trials and 35 included data for the detection of antimicrobial resistance. When comparing data for patients in intervention groups (those who received SDD or SOD) versus data for those in control groups (who received no intervention), we identified no difference in the prevalence of colonisation or infection with Gram-positive antimicrobial-resistant pathogens of interest, including meticillin-resistant Staphylococcus aureus (odds ratio 1·46, 95% CI 0·90-2·37) and vancomycin-resistant enterococci (0·63, 0·39-1·02). Among Gram-negative bacilli, we detected no difference in aminoglycoside-resistance (0·73, 0·51-1·05) or fluoroquinolone-resistance (0·52, 0·16-1·68), but we did detect a reduction in polymyxin-resistant Gram-negative bacilli (0·58, 0·46-0·72) and third-generation cephalosporin-resistant Gram-negative bacilli (0·33, 0·20-0·52) in recipients of selective decontamination compared with those who received no intervention. We detected no relation between the use of SDD or SOD and the development of antimicrobial-resistance in pathogens in patients in the ICU, suggesting that the perceived risk of long-term harm related to selective decontamination cannot be justified by available data. However, our study indicates that the effect of decontamination on ICU-level antimicrobial resistance rates is understudied. We recommend that future research includes a non-crossover, cluster randomised controlled trial to assess long-term ICU-level changes in resistance rates. None. Copyright © 2013 Elsevier Ltd. All rights reserved.
Probiotics versus antibiotic decontamination of the digestive tract: infection and mortality.
Oudhuis, Guy J; Bergmans, Dennis C; Dormans, Tom; Zwaveling, Jan-Harm; Kessels, Alfons; Prins, Martin H; Stobberingh, Ellen E; Verbon, Annelies
2011-01-01
Selective decontamination of the digestive tract (SDD) has been shown to decrease the infection rate and mortality in intensive care units (ICUs); Lactobacillus plantarum 299/299v plus fibre (LAB) has been used for infection prevention and does not harbour the potential disadvantages of antibiotics. The objective was to assess whether LAB is not inferior to SDD in infection prevention. Two hundred fifty-four consecutive ICU patients with expected mechanical ventilation ≥ 48 h and/or expected ICU stay ≥ 72 h were assigned to receive SDD: four times daily an oral paste (polymyxin E, gentamicin, amphotericin B), enteral solution (same antibiotics), intravenous cefotaxime (first 4 days) or LAB: two times daily L. plantarum 299/299v with rose-hip. The primary endpoint was infection rate. A difference <12% between both groups indicated non-inferiority of LAB. The trial was prematurely stopped after a study reporting increased mortality in critically ill pancreatitis patients receiving probiotics. No significant difference in infection rate [31% in the LAB group, 24% in the SDD group (OR 1.68, 95% CI 0.91-3.08; p = 0.10)] was found. ICU mortality was 26% and not significantly different between the LAB and SDD groups. Gram-positive cocci and Pseudomonas aeruginosa were significantly more frequently isolated from surveillance cultures in the SDD group compared to the LAB group (for sputum: 18 vs. 10% and 33 vs. 14%). Significantly more Enterobacteriaceae were found in the LAB group (23 vs. 50%). No increase in antibiotic resistance was found during and after SDD or LAB use. The trial could not demonstrate the non-inferiority of LAB compared with SDD in infection prevention. Results suggest no increased ICU mortality risk in the LAB group.
Oostdijk, Evelien A N; Kesecioglu, Jozef; Schultz, Marcus J; Visser, Caroline E; de Jonge, Evert; van Essen, Einar H R; Bernards, Alexandra T; Purmer, Ilse; Brimicombe, Roland; Bergmans, Dennis; van Tiel, Frank; Bosch, Frank H; Mascini, Ellen; van Griethuysen, Arjanne; Bindels, Alexander; Jansz, Arjan; van Steveninck, Fred A L; van der Zwet, Wil C; Fijen, Jan Willem; Thijsen, Steven; de Jong, Remko; Oudbier, Joke; Raben, Adrienne; van der Vorm, Eric; Koeman, Mirelle; Rothbarth, Philip; Rijkeboer, Annemieke; Gruteke, Paul; Hart-Sweet, Helga; Peerbooms, Paul; Winsser, Lex J; van Elsacker-Niele, Anne-Marie W; Demmendaal, Kees; Brandenburg, Afke; de Smet, Anne Marie G A; Bonten, Marc J M
2014-10-08
Selective decontamination of the digestive tract (SDD) and selective oropharyngeal decontamination (SOD) are prophylactic antibiotic regimens used in intensive care units (ICUs) and associated with improved patient outcome. Controversy exists regarding the relative effects of both measures on patient outcome and antibiotic resistance. To compare the effects of SDD and SOD, applied as unit-wide interventions, on antibiotic resistance and patient outcome. Pragmatic, cluster randomized crossover trial comparing 12 months of SOD with 12 months of SDD in 16 Dutch ICUs between August 1, 2009, and February 1, 2013. Patients with an expected length of ICU stay longer than 48 hours were eligible to receive the regimens, and 5881 and 6116 patients were included in the clinical outcome analysis for SOD and SDD, respectively. Intensive care units were randomized to administer either SDD or SOD. Unit-wide prevalence of antibiotic-resistant gram-negative bacteria. Secondary outcomes were day-28 mortality, ICU-acquired bacteremia, and length of ICU stay. In point-prevalence surveys, prevalences of antibiotic-resistant gram-negative bacteria in perianal swabs were significantly lower during SDD compared with SOD; for aminoglycoside resistance, average prevalence was 5.6% (95% CI, 4.6%-6.7%) during SDD and 11.8% (95% CI, 10.3%-13.2%) during SOD (P < .001). During both interventions the prevalence of rectal carriage of aminoglycoside-resistant gram-negative bacteria increased 7% per month (95% CI, 1%-13%) during SDD (P = .02) and 4% per month (95% CI, 0%-8%) during SOD (P = .046; P = .40 for difference). Day 28-mortality was 25.4% and 24.1% during SOD and SDD, respectively (adjusted odds ratio, 0.96 [95% CI, 0.88-1.06]; P = .42), and there were no statistically significant differences in other outcome parameters or between surgical and nonsurgical patients. Intensive care unit-acquired bacteremia occurred in 5.9% and 4.6% of the patients during SOD and SDD, respectively (odds ratio, 0.77 [95% CI, 0.65-0.91]; P = .002; number needed to treat, 77). Unit-wide application of SDD and SOD was associated with low levels of antibiotic resistance and no differences in day-28 mortality. Compared with SOD, SDD was associated with lower rectal carriage of antibiotic-resistant gram-negative bacteria and ICU-acquired bacteremia but a more pronounced gradual increase in aminoglycoside-resistant gram-negative bacteria. trialregister.nlIdentifier: NTR1780.
Teng, Chaoyi; Demers, Hendrix; Brodusch, Nicolas; Waters, Kristian; Gauvin, Raynald
2018-06-04
A number of techniques for the characterization of rare earth minerals (REM) have been developed and are widely applied in the mining industry. However, most of them are limited to a global analysis due to their low spatial resolution. In this work, phase map analyses were performed on REM with an annular silicon drift detector (aSDD) attached to a field emission scanning electron microscope. The optimal conditions for the aSDD were explored, and the high-resolution phase maps generated at a low accelerating voltage identify phases at the micron scale. In comparisons between an annular and a conventional SDD, the aSDD performed at optimized conditions, making the phase map a practical solution for choosing an appropriate grinding size, judging the efficiency of different separation processes, and optimizing a REM beneficiation flowsheet.
Stoustrup, Peter; Kristensen, Kasper D; Verna, Carlalberta; Küseler, Annelise; Herlin, Troels; Pedersen, Thomas K
2012-12-01
Temporomandibular joint (TMJ) inflammation in patients with juvenile idiopathic arthritis (JIA) may lead to mandibular growth disturbances and interfere with optimal joint and muscle function. Orofacial symptoms are common clinical findings in relation to TMJ arthritis in adolescence. Knowledge about their clinical manifestation is important for TMJ arthritis diagnosis, treatment choice, and outcome evaluation. The aim of our prospective observational study was to evaluate and describe the frequency, the main complaints, and the localization of TMJ arthritis-related orofacial symptoms. The smallest detectable differences (SDD) for minimal, average, and maximal pain were estimated. Thirty-three patients with JIA and arthritis-related orofacial symptoms in relation to 55 affected TMJ were included in our questionnaire study (mean age 14.11 yrs). Calculation of the SDD was based on a duplicate assessment 45 min after the first questionnaire was completed. The majority of the patients had common orofacial symptoms during mastication and maximal mouth opening procedures. Persistent orofacial symptoms were rare. The TMJ area in combination with the masseter muscle region was the orofacial region where symptoms were most common. The SDD for minimal, average, and maximal pain were between 10 and 14 mm on a visual analog scale. Our study offers new knowledge about TMJ arthritis-related orofacial symptoms that may aid diagnosis and clinical decision-making. We suggest that TMJ arthritis-related orofacial symptoms could be understood as products of the primary TMJ inflammation in combination with secondary myogenic and functional issues.
van Till, Jw Olivier; van Ruler, Oddeke; Lamme, Bas; Weber, Roy J P; Reitsma, Johannes B; Boermeester, Marja A
2007-01-01
The objective of this study was to determine and compare the effectiveness of different prophylactic antifungal therapies in critically ill patients on the incidence of yeast colonisation, infection, candidemia, and hospital mortality. A systematic review was conducted of prospective trials including adult non-neutropenic patients, comparing single-drug antifungal prophylaxis (SAP) or selective decontamination of the digestive tract (SDD) with controls and with each other. Thirty-three studies were included (11 SAP and 22 SDD; 5,529 patients). Compared with control groups, both SAP and SDD reduced the incidence of yeast colonisation (SAP: odds ratio [OR] 0.38, 95% confidence interval [CI] 0.20 to 0.70; SDD: OR 0.12, 95% CI 0.05 to 0.29) and infection (SAP: OR 0.54, 95% CI 0.39 to 0.75; SDD: OR 0.29, 95% CI 0.18 to 0.45). Treatment effects were significantly larger in SDD trials than in SAP trials. The incidence of candidemia was reduced by SAP (OR 0.32, 95% CI 0.12 to 0.82) but not by SDD (OR 0.59, 95% CI 0.25 to 1.40). In-hospital mortality was reduced predominantly by SDD (OR 0.73, 95% CI 0.59 to 0.93, numbers needed to treat 15; SAP: OR 0.80, 95% CI 0.64 to 1.00). Effectiveness of prophylaxis reduced with an increased proportion of included surgical patients. Antifungal prophylaxis (SAP or SDD) is effective in reducing yeast colonisation and infections across a range of critically ill patients. Indirect comparisons suggest that SDD is more effective in reducing yeast-related outcomes, except for candidemia.
Mol, Meriel; van Kan, Hendrikus J M; Schultz, Marcus J; de Jonge, Evert
2008-05-01
To study whether selective decontamination of the digestive tract (SDD) results in detectable serum tobramycin concentrations in intensive care unit (ICU) patients with acute renal failure treated with continuous venovenous hemofiltration (CVVH). Prospective, observational, single-center study in a mixed medical-surgical ICU. Adult ICU patients receiving SDD for at least 3 days and being treated with CVVH because of acute renal failure. Tobramycin serum concentrations were measured at the 3rd day after start of CVVH and every 3 days thereafter. Detectable serum concentrations of tobramycin were found in 12 (63%) of 19 patients and in 15 (58%) of the 26 samples. With a toxic tobramycin concentration defined as more than 2.0 mg/l, we found one patient with a toxic concentration of 3.0 mg/l. In three other patients tobramycin concentrations of >or=1.0 mg/l were found. In patients with acute renal failure treated with CVVH, administration of SDD with tobramycin can lead to detectable and potentially toxic serum tobramycin concentrations.
Mascali, D; Celona, L; Maimone, F; Maeder, J; Castro, G; Romano, F P; Musumarra, A; Altana, C; Caliri, C; Torrisi, G; Neri, L; Gammino, S; Tinschert, K; Spaedtke, K P; Rossbach, J; Lang, R; Ciavola, G
2014-02-01
An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source - operating at GSI, Darmstadt - has been carried out. Two different detectors (a SDD - Silicon Drift Detector and a HpGe - hyper-pure Germanium detector) have been used to characterize the warm (2-30 keV) and hot (30-500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract the plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.
Repeated psychosocial stress at night affects the circadian activity rhythm of male mice.
Bartlang, Manuela S; Oster, Henrik; Helfrich-Förster, Charlotte
2015-06-01
We have recently shown that molecular rhythms in the murine suprachiasmatic nucleus (SCN) are affected by repeated social defeat (SD) during the dark/active phase (social defeat dark [SDD]), while repeated SD during the light/inactive phase (social defeat light [SDL]) had no influence on PERIOD2::LUCIFERASE explant rhythms in the SCN. Here we assessed the effects of the same stress paradigm by in vivo biotelemetry on 2 output rhythms of the circadian clock (i.e., activity and core body temperature) in wild-type (WT) and clock-deficient Period (Per)1/2 double-mutant mice during and following repeated SDL and SDD. In general, stress had more pronounced effects on activity compared to body temperature rhythms. Throughout the SD procedure, activity and body temperature were markedly increased during the 2 h of stressor exposure at zeitgeber time (ZT) 1 to ZT3 (SDL mice) and ZT13 to ZT15 (SDD mice), which was compensated by decreased activity during the remaining dark phase (SDL and SDD mice) and light phase (SDL mice) in both genotypes. Considerable differences in the activity between SDL and SDD mice were seen in the poststress period. SDD mice exhibited a reduced first activity bout at ZT13, delayed activity onset, and, consequently, a more narrow activity bandwidth compared with single-housed control (SHC) and SDL mice. Given that this effect was absent in Per1/2 mutant SDD mice and persisted under constant darkness conditions in SDD WT mice, it suggests an involvement of the endogenous clock. Taken together, the present findings demonstrate that SDD has long-lasting consequences for the functional output of the biological clock that, at least in part, appear to depend on the clock genes Per1 and Per2. © 2015 The Author(s).
Fang, Yuan; Zheng, Tao; Liu, Lanxiang; Gao, Dawei; Shi, Qinglei; Dong, Yanchao; Du, Dan
2017-11-17
Simple diffusion delivery (SDD) has attained good effects with only tiny amounts of drugs. Fractional anisotropy (FA) and relaxation time T2* that indicate the integrity of fiber tracts and iron concentration within brain tissue were used to evaluate the therapeutic effect of SDD. To evaluate therapeutic effect of SDD in the Parkinson's disease (PD) rat model with FA and T2* parameters. Prospective case-control animal study. Thirty-two male Sprague Dawley rats (eight normal, eight PD, eight SDD, and eight subcutaneous injection rats). Single-shot spin echo echo-planar imaging and fast low-angle shot T 2 WI sequences at 3.0T. Parameters of FA and T2* on the treated side of the substantia nigra were measured to evaluate the therapeutic effect of SDD in a PD rat model. The effects of time on FA and T2* values were analyzed by repeated measurement tests. A one-way analysis of variance was conducted, followed by individual comparisons of the mean FA and T2* values at different timepoints. The FA values on the treated side of the substantia nigra in the SDD treatment group and subcutaneous injection treatment group were significantly higher at week 1 and lower at week 6 than that of the PD control group (SDD vs. PD, week 1, adjusted P = 0.012; subcutaneous vs. PD, week 1, adjusted P < 0.001; SDD vs. PD, week 6, adjusted P = 0.004; subcutaneous vs. PD, week 6, adjusted P = 0.024). The T2* parameter in the SDD treatment group and subcutaneous injection treatment group was significantly higher than that in the PD control group at week 6 (SDD vs. PD, adjusted P = 0.032; subcutaneous vs. PD, adjusted P < 0.001). The combination of FA and T2* parameters can potentially serve as a new effective evaluation method of the therapeutic effect of SDD. 1 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Subretinal Drusenoid Deposits AKA Pseudodrusen.
Spaide, Richard F; Ooto, Sotaro; Curcio, Christine A
2018-05-30
A distinction between conventional drusen and pseudodrusen was first made in 1990, and more recently knowledge of pseudodrusen, more accurately called subretinal drusenoid deposits (SDD), has expanded. Pseudodrusen have a bluish-white appearance by biomicroscopy and color fundus photography. Using optical coherence tomography, pseudodrusen were found to be accumulations of material internal to the retinal pigment epithelium (RPE) that could extend internally through the ellipsoid zone. These deposits are more commonly seen in older eyes with thinner choroids. Histologic evaluation of these deposits revealed aggregations of material in the subretinal space between photoreceptors and RPE. SDD contain some proteins in common with soft drusen, but differ in lipid composition. Many studies reported that SDD are strong independent risk factors for late age-related macular degeneration (AMD). Geographic atrophy and Type 3 neovascularization are particularly associated with SDD. Unlike conventional drusen, eyes with SDD show slowed dark adaptation and poor contrast sensitivity. Eyes with regression of SDD develop outer retinal atrophy, which is a newly recognized form of late AMD. Advances in imaging technology have enabled many insights into this condition, including associated photoreceptor, RPE, and underlying choroidal changes. Copyright © 2018. Published by Elsevier Inc.
Amin, Amit P; Patterson, Mark; House, John A; Giersiefen, Helmut; Spertus, John A; Baklanov, Dmitri V; Chhatriwalla, Adnan K; Safley, David M; Cohen, David J; Rao, Sunil V; Marso, Steven P
2017-02-27
The aim of this study was to examine the independent impact of various care pathways, including those involving transradial intervention (TRI) and same-day discharge (SDD) after elective percutaneous coronary intervention (PCI), on hospital costs. PCI is associated with costs of $10 billion annually. Alternative payment models for PCI are being implemented, but few data exist on strategies to reduce costs. Various PCI care pathways, including TRI and SDD, exist, but their association with costs and outcomes is unknown. In total, 279,987 PCI patients eligible for SDD in the National Cardiovascular Data Registry CathPCI Registry linked to Medicare claims files were analyzed. Hospital costs in 2014 U.S. dollars were estimated using cost-to-charge ratios. Propensity scores for TRI and SDD, with propensity adjustment via inverse probability weighting, was performed. Of the 279,987 PCI procedures, TRI was used in 9.0% (13.5% of which were SDD), and SDD was used in 5.3% of cases (23.1% of which were TRI). TRI (vs. transfemoral intervention) was associated with lower adjusted costs of $916 (95% confidence interval [CI]: $778 to $1,035), as was SDD ($3,502; 95% CI: $3,486 to $3,902). The adjusted cost associated with TRI and SDD was $13,389 (95% CI: $13,161 to $13,607), while the cost associated with transfemoral intervention and non-same-day discharge was $17,076 (95% CI: $16,999 to $17,147), a difference of $3,689 (95% CI: $3,486 to $3,902; p < 0.0001). Shifting current practice from transfemoral intervention non-same-day discharge to TRI SDD by 30% could potentially save a hospital performing 1,000 PCIs each year $1 million and the country $300 million annually. Among Medicare beneficiaries, TRI with SDD was independently associated with fewer complications and lower in-hospital costs. These findings have important implications for changing the current PCI care pathways to improve outcomes and reduce costs. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Dahms, R; Carlson, M; Lohr, B; Beilman, G
2000-09-01
Vancomycin-resistant Enterococcus (VRE) has emerged as a significant nosocomial pathogen in the surgical intensive care unit (SICU). We wished to test the hypothesis that the use of selective digestive tract decontamination (SDD) in the SICU affects the frequency of VRE isolation. A retrospective review of hospital records and the SICU database was performed using patients admitted to the SICU service for three or more days from January 1, 1996 to December 31, 1999 at our large tertiary-care teaching hospital. During this time use of SDD in selected patient populations decreased due to physician preference. Information gathered included length of SICU stay, presence of VRE infection or colonization, and use and duration of SDD protocol, vancomycin, and ceftazidime. There were 110 newly diagnosed VRE cases in the SICU during this time period. During the same time period 54 patients received SDD. Eight patients who received SDD had positive VRE cultures and seven had the initial positive culture after receiving SDD. Overall, 9.1% of eligible SICU patients received SDD, 18.5% of patients in the SICU for over 3 days had VRE, 7.3% of VRE patients received SDD, and 13.0% of the SICU patients who received SDD subsequently developed VRE. SDD use was not associated with VRE in univariate analysis. Logistic regression analysis showed higher odds ratios for SDD use in combination with vancomycin than for vancomycin use alone (OR=4.3 vs. 10.9). Odds ratios were over three times higher for SDD plus vancomycin plus ceftazidime use when compared to vancomycin plus ceftazidime use alone (OR=70.5 vs. 19.8). We conclude that administration of SDD alone did not correlate with increased VRE isolation, but that SDD use in conjunction with vancomycin and ceftazidime was associated with VRE isolation.
Plantinga, N L; de Smet, A M G A; Oostdijk, E A N; de Jonge, E; Camus, C; Krueger, W A; Bergmans, D; Reitsma, J B; Bonten, M J M
2018-05-01
Selective digestive decontamination (SDD) and selective oropharyngeal decontamination (SOD) improved intensive care unit (ICU), hospital and 28-day survival in ICUs with low levels of antibiotic resistance. Yet it is unclear whether the effect differs between medical and surgical ICU patients. In an individual patient data meta-analysis, we systematically searched PubMed and included all randomized controlled studies published since 2000. We performed a two-stage meta-analysis with separate logistic regression models per study and per outcome (hospital survival and ICU survival) and subsequent pooling of main and interaction effects. Six studies, all performed in countries with low levels of antibiotic resistance, yielded 16 528 hospital admissions and 17 884 ICU admissions for complete case analysis. Compared to standard care or placebo, the pooled adjusted odds ratios for hospital mortality was 0.82 (95% confidence interval (CI) 0.72-0.93) for SDD and 0.84 (95% CI 0.73-0.97) for SOD. Compared to SOD, the adjusted odds ratio for hospital mortality was 0.90 (95% CI 0.82-0.97) for SDD. The effects on hospital mortality were not modified by type of ICU admission (p values for interaction terms were 0.66 for SDD and control, 0.87 for SOD and control and 0.47 for SDD and SOD). Similar results were found for ICU mortality. In ICUs with low levels of antibiotic resistance, the effectiveness of SDD and SOD was not modified by type of ICU admission. SDD and SOD improved hospital and ICU survival compared to standard care in both patient populations, with SDD being more effective than SOD. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mascali, D., E-mail: davidmascali@lns.infn.it; Celona, L.; Castro, G.
2014-02-15
An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source – operating at GSI, Darmstadt – has been carried out. Two different detectors (a SDD – Silicon Drift Detector and a HpGe – hyper-pure Germanium detector) have been used to characterize the warm (2–30 keV) and hot (30–500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract themore » plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.« less
Galloway, David; Danziger-Isakov, Lara; Goldschmidt, Monique; Hemmelgarn, Trina; Courter, Joshua; Nathan, Jaimie D; Alonso, Maria; Tiao, Greg; Fei, Lin; Kocoshis, Samuel
2015-11-01
Pediatric patients undergoing small bowel transplantation are susceptible to postoperative CLABSI. SDD directed against enteric microbes is a strategy for reducing CLABSI. We hypothesized that SDD reduces the frequency of CLABSI, infections outside the bloodstream, and allograft rejection during the first 30 days following transplant. A retrospective chart review of 38 pediatric small bowel transplant recipients at CCHMC from 2003 to 2011 was conducted. SDD antimicrobials were oral colistin, tobramycin, and amphotericin B. The incidence of CLABSI, infections outside the bloodstream, and rejection episodes were compared between study periods. The incidence of CLABSI did not differ between study periods (6.9 CLABSI vs. 4.6 CLABSI per 1000 catheter days; p = 0.727), but gram positives and Candida predominated in the first 30 days. Incidence of bacterial infections outside the bloodstream did not differ (p = 0.227). Rejection occurred more frequently during the first month following transplant (p = 0.302). SDD does not alter the incidence of CLABSI, bacterial infections outside the bloodstream, or allograft rejection in the immediate 30 days post-transplantation. However, SDD does influence CLABSI organism types (favoring gram positives and Candida) and Candidal infections outside the bloodstream. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dai, Tingting; Duan, Jie; Li, Xinghua; Xu, Xiangdong; Shi, Hongmei; Kang, Weijun
2017-06-16
The presence of sulfonamide (SA) residues in foods is largely due to the raising of animals with sulfonamide antibiotics added or polluted feedstuff. In this paper, a sensitive method was developed for the determination of the residues of three sulfonamides in animal-derived food; the SAs include sulfadimidine (SDD), sulfadiazine (SDZ), and sulfathiazole (STZ). The method is based on capillary zone electrophoresis (CE) with online chemiluminescence (CL) detection, using an Ag(III) complex as an oxidant. These SAs have an inhibiting effect on the Ag(III)-luminol CL reaction. The electrophoretic buffer is 12.0 mM sodium borate. Under a set of optimized conditions, the linear ranges for the detections were found to be 10.0-200 µg·mL -1 for SDD and SDZ, and 2.0-50.0 µg·mL -1 for STZ. The detection limits were 2.75, 3.14, and 0.65 µg·mL -1 for SDD, SDZ, and STZ, respectively. Relative standard deviations (RSD) for the peak heights were between 2.1% and 2.8% (n = 7). The proposed method was used in the analysis of the SAs in samples from pork meat, chicken meat, and milk, showing satisfactory detection results. A reaction mechanism was also proposed for the Ag(III)-luminol-SA CL reactions. The method has potential applications for the monitoring of residue levels of the three SAs in food, providing food safety data.
NASA Technical Reports Server (NTRS)
Gaskin, Jessica A.; Carini, Gabriella A.; Wei, Chen; Elsner, Ronald F.; Kramer, Georgiana; De Geronimo, Gianluigi; Keister, Jeffrey W.; Zheng, Li; Ramsey, Brian D.; Rehak, Pavel;
2009-01-01
Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.
Shipkowski, Kelly A; Sheth, Christopher M; Smith, Matthew J; Hooth, Michelle J; White, Kimber L; Germolec, Dori R
2017-12-01
Sodium dichromate dihydrate (SDD), an inorganic compound containing hexavalent chromium (Cr(VI)), is a common environmental contaminant of groundwater sources due to widespread industrial use. There are indications in the literature that Cr(VI) may induce immunotoxic effects following dermal exposure, including acting as both an irritant and a sensitizer; however, the potential immunomodulatory effects of Cr(VI) following oral exposure are relatively unknown. Following the detection of Cr(VI) in drinking water sources, the National Toxicology Program (NTP) conducted extensive evaluations of the toxicity and carcinogenicity of SDD following drinking water exposure, including studies to assess the potential for Cr(VI) to modulate immune function. For the immunotoxicity assessments, female Fischer 344/N (F344/N) and Sprague Dawley (SD) rats and female B 6 C 3 F 1 mice were exposed to SDD in drinking water for 28 consecutive days and evaluated for alterations in cellular and humoral immune function as well as innate immunity. Rats were exposed to concentrations of 0, 14.3, 57.3, 172, or 516 ppm SDD while mice were exposed to concentrations of 0, 15.6, 31.3, 62.5, 125, or 250 ppm SDD. Final mean body weight and body weight gain were decreased relative to controls in 250 ppm B 6 C 3 F 1 mice and 516 ppm SD rats. Water consumption was significantly decreased in F344/N and SD rats exposed to 172 and 516 ppm SDD; this was attributed to poor palatability of the SDD drinking water solutions. Several red blood cell-specific parameters were significantly (5-7%) decreased in 250 ppm mice; however, these parameters were unaffected in rats. Sporadic increases in the spleen IgM antibody response to sheep red blood cells (SRBC) were observed, however, these increases were not dose-dependent and were not reproducible. No significant effects were observed in the other immunological parameters evaluated. Overall, exposure to Cr(VI) in drinking water had limited effects on the immune system in both rats and mice.
Dai, Tingting; Duan, Jie; Li, Xinghua; Xu, Xiangdong; Shi, Hongmei; Kang, Weijun
2017-01-01
The presence of sulfonamide (SA) residues in foods is largely due to the raising of animals with sulfonamide antibiotics added or polluted feedstuff. In this paper, a sensitive method was developed for the determination of the residues of three sulfonamides in animal-derived food; the SAs include sulfadimidine (SDD), sulfadiazine (SDZ), and sulfathiazole (STZ). The method is based on capillary zone electrophoresis (CE) with online chemiluminescence (CL) detection, using an Ag(III) complex as an oxidant. These SAs have an inhibiting effect on the Ag(III)–luminol CL reaction. The electrophoretic buffer is 12.0 mM sodium borate. Under a set of optimized conditions, the linear ranges for the detections were found to be 10.0–200 µg·mL−1 for SDD and SDZ, and 2.0–50.0 µg·mL−1 for STZ. The detection limits were 2.75, 3.14, and 0.65 µg·mL−1 for SDD, SDZ, and STZ, respectively. Relative standard deviations (RSD) for the peak heights were between 2.1% and 2.8% (n = 7). The proposed method was used in the analysis of the SAs in samples from pork meat, chicken meat, and milk, showing satisfactory detection results. A reaction mechanism was also proposed for the Ag(III)–luminol–SA CL reactions. The method has potential applications for the monitoring of residue levels of the three SAs in food, providing food safety data. PMID:28621728
A Programmable Smoke Delivery Device for PET Imaging with Cigarettes Containing 11C-nicotine
Zuo, Yantao; Garg, Pradeep K; Nazih, Rachid; Garg, Sudha; Rose, Jed E; Murugesan, Thangaraju; Mukhin, Alexey G
2017-01-01
Introduction PET imaging with 11C-nicotine-loaded cigarettes is a valuable tool to directly assess fast nicotine kinetics and its neuropharmacological role in tobacco dependence. To eliminate variations among puffs inhaled by subjects, this work aimed to develop a programmable smoke delivery device (SDD) to produce highly reproducible and adjustable puffs of cigarette smoke for PET experiments. New method The SDD was built around a programmable syringe pump as a smoking machine to draw a puff of smoke from a 11C-nicotine-loaded cigarette and make it available for a subject to take the smoke into the mouth and then inhale it during PET data acquisition. Brain nicotine time activity curves and total body absorbed 11C-nicotine doses (TAD) were measured in smokers who inhaled a single puff of smoke via the SDD from a 11C-nicotine-loaded cigarette. Results Nearly identical brain nicotine kinetics were observed between participants who inhaled a puff of smoke through the SDD and those who inhaled directly from a cigarette. Comparison with existing methods This new device minimizes puff variations that exist with earlier smoke delivery apparatuses which could introduce confounding factors. Conclusions The SDD is effective in delivering 11C-nicotine from the study cigarettes. Despite a 2-sec increase in aging of smoke delivered through the SDD versus smoke taken directly from a cigarette, the difference in brain nicotine kinetics after 11C-nicotine delivery with and without use of the SDD is negligible. This refined device may be useful for future research on the deposition and pharmacokinetics of nicotine inhaled with tobacco smoke. PMID:28347784
A programmable smoke delivery device for PET imaging with cigarettes containing 11C-nicotine.
Zuo, Yantao; Garg, Pradeep K; Nazih, Rachid; Garg, Sudha; Rose, Jed E; Murugesan, Thangaraju; Mukhin, Alexey G
2017-05-01
PET imaging with 11 C-nicotine-loaded cigarettes is a valuable tool to directly assess fast nicotine kinetics and its neuropharmacological role in tobacco dependence. To eliminate variations among puffs inhaled by subjects, this work aimed to develop a programmable smoke delivery device (SDD) to produce highly reproducible and adjustable puffs of cigarette smoke for PET experiments. The SDD was built around a programmable syringe pump as a smoking machine to draw a puff of smoke from a 11 C-nicotine-loaded cigarette and make it available for a subject to take the smoke into the mouth and then inhale it during PET data acquisition. Brain nicotine time activity curves and total body absorbed 11 C-nicotine doses (TAD) were measured in smokers who inhaled a single puff of smoke via the SDD from a 11 C-nicotine-loaded cigarette. Nearly identical brain nicotine kinetics were observed between participants who inhaled a puff of smoke through the SDD and those who inhaled directly from a cigarette. This new device minimizes puff variations that exist with earlier smoke delivery apparatuses which could introduce confounding factors. The SDD is effective in delivering 11 C-nicotine from the study cigarettes. Despite a 2-s increase in aging of smoke delivered through the SDD versus smoke taken directly from a cigarette, the difference in brain nicotine kinetics after 11 C-nicotine delivery with and without use of the SDD is negligible. This refined device may be useful for future research on the deposition and pharmacokinetics of nicotine inhaled with tobacco smoke. Copyright © 2017 Elsevier B.V. All rights reserved.
Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study
Bazalova-Carter, Magdalena; Ahmad, Moiz; Xing, Lei; Fahrig, Rebecca
2015-01-01
Abstract. Thanks to the current advances in nanoscience, molecular biochemistry, and x-ray detector technology, x-ray fluorescence computed tomography (XFCT) has been considered for molecular imaging of probes containing high atomic number elements, such as gold nanoparticles. The commonly used XFCT imaging performed with K-shell x rays appears to have insufficient imaging sensitivity to detect the low gold concentrations observed in small animal studies. Low energy fluorescence L-shell x rays have exhibited higher signal-to-background ratio and appeared as a promising XFCT mode with greatly enhanced sensitivity. The aim of this work was to experimentally demonstrate the feasibility of L-shell XFCT imaging and to assess its achievable sensitivity. We built an experimental L-shell XFCT imaging system consisting of a miniature x-ray tube and two spectrometers, a silicon drift detector (SDD), and a CdTe detector placed at ±120 deg with respect to the excitation beam. We imaged a 28-mm-diameter water phantom with 4-mm-diameter Eppendorf tubes containing gold solutions with concentrations of 0.06 to 0.1% Au. While all Au vials were detectable in the SDD L-shell XFCT image, none of the vials were visible in the CdTe L-shell XFCT image. The detectability limit of the presented L-shell XFCT SDD imaging setup was 0.007% Au, a concentration observed in small animal studies. PMID:26839910
Diepenhorst, Gwendolyn M P; van Ruler, Oddeke; Besselink, Marc G H; van Santvoort, Hjalmar C; Wijnandts, Paul R; Renooij, Willem; Gouma, Dirk J; Gooszen, Hein G; Boermeester, Marja A
2011-01-01
Bacterial translocation (BT) is suspected to play a major role in the development of infections in surgical patients. However, the clinical association between intestinal barrier dysfunction, BT, and septic morbidity has remained unconfirmed. The objective of this study was to study BT in patients undergoing major abdominal surgery and the effects of probiotics, selective decontamination of the digestive tract (SDD), and standard treatment on intestinal barrier function. In a randomized controlled setting, 30 consecutive patients planned for elective pylorus-preserving pancreaticoduodenectomy (PPPD) were allocated to receive perioperatively probiotics, SDD, or standard treatment. To assess intestinal barrier function, intestinal fatty acid-binding protein (mucosal damage) and polyethylene glycol recovery (intestinal permeability) in urine were measured perioperatively. BT was assessed by real-time polymerase chain reaction and multiplex ligation-dependent probe amplification (MLPA) in mesenteric lymph nodes (MLNs) harvested early (baseline control) and at the end of surgery ("end-of-surgery" MLNs, after 3h in PPPD patients). Polymerase chain reaction detected bacterial DNA in 18 of 27 end-of-surgery MLNs and in 13 of 23 control MLNs (P = 0.378). Probiotics and SDD had no significant effect on the number of positive MLNs or the change in bacterial DNA during operation. Multiplex ligation-dependent probe amplification analysis showed significantly increased expression of only 4 of 30 inflammatory mediator-related genes in end-of-surgery compared with early sampled MLN (P < 0.05). Polyethylene glycol recovery was unaffected by operation, probiotics and SDD as compared with standard treatment. Intestinal fatty acid-binding protein levels were increased shortly postoperatively only in patients treated with SDD (P = 0.02). Probiotics and SDD did not influence BT, intestinal permeability, or inflammatory mediator expression. Bacterial translocation after abdominal surgery may be part of normal antigen-sampling processes of the gut.
Newbury, Dale E
2006-12-01
Two recent developments in X-ray spectrometer technology provide dramatic improvements in analytical capabilities that impact the frontiers of electron microscopy. Silicon drift detectors (SDD) use the same physics as silicon (lithium) energy dispersive spectrometers [Si(Li) EDS] but differ in design: only 10% of the thickness of the Si(Li) EDS with an anode area below 0.1 mm2 and a complex rear surface electrode pattern that creates a lateral internal charge collection field. The SDD equals or betters the Si(Li) EDS in most measures of performance. For output versus input count rate, the SDD exceeds the Si(Li) EDS by a factor of 5 to 10 for the same resolution. This high throughput can benefit analytical measurements that are count limited, such as X-ray mapping and trace measurements. The microcalorimeter EDS determines the X-ray energy by measuring the temperature rise in a metal absorber. Operating at 100 mK, the microcalorimeter EDS achieves resolution of 2-5 eV over a photon energy range of 200 eV to 10 keV in energy dispersive operation, eliminating most peak interference situations and providing high peak-to-background to detect low fluorescence yield peaks. Chemical bonding effects on low energy (< 2 keV) peak shapes can be measured.
Zarubina, Anna V; Gal-Or, Orly; Huisingh, Carrie E; Owsley, Cynthia; Freund, K Bailey
2017-12-01
To explore the association between presence of subretinal drusenoid deposits (SDD) at baseline in eyes with neovascular age-related macular degeneration (nAMD) with the development of macular atrophy (MA) during anti-vascular endothelial growth factor (VEGF) therapy. There were 74 eyes without pre-existing MA receiving anti-VEGF therapy for nAMD for 2 years or longer analyzed. At least two image modalities that included spectral-domain optical coherence tomography, near-infrared reflectance, fluorescein angiography, and color fundus photos were used to assess for SDD presence, phenotype (dot and ribbon), and location, neovascularization type, and MA. Logistic regression models using generalized estimating equations assessed the association between SDD and the development of MA adjusting for age, neovascularization type, and choroidal thickness. SDD were present in 46 eyes (63%) at baseline. MA developed in 38 eyes (51%) during the mean of 4.7 ± 1.2 years of follow-up. Compared with eyes without SDD, those with SDD at baseline were 3.0 times (95% confidence interval [CI] 1.1-8.5, P = 0.0343) more likely to develop MA. Eyes with SDD present in the inferior macula and inferior extramacular fields at baseline were 3.0 times and 6.5 times more likely to develop MA at follow-up than eyes without SDD in these locations (95% CI 1.0-8.9, P = 0.0461 and 95% CI 1.3-32.4, P = 0.0218, respectively). MA development was not associated with a specific SDD phenotype. MA frequently developed in eyes during anti-VEGF treatment. SDD were independently associated with MA development. The extension of SDD into the inferior fundus, particularly in the inferior extramacular field, conferred higher odds of subsequent MA development.
Zarubina, Anna V.; Gal-Or, Orly; Huisingh, Carrie E.; Owsley, Cynthia
2017-01-01
Purpose To explore the association between presence of subretinal drusenoid deposits (SDD) at baseline in eyes with neovascular age-related macular degeneration (nAMD) with the development of macular atrophy (MA) during anti-vascular endothelial growth factor (VEGF) therapy. Methods There were 74 eyes without pre-existing MA receiving anti-VEGF therapy for nAMD for 2 years or longer analyzed. At least two image modalities that included spectral-domain optical coherence tomography, near-infrared reflectance, fluorescein angiography, and color fundus photos were used to assess for SDD presence, phenotype (dot and ribbon), and location, neovascularization type, and MA. Logistic regression models using generalized estimating equations assessed the association between SDD and the development of MA adjusting for age, neovascularization type, and choroidal thickness. Results SDD were present in 46 eyes (63%) at baseline. MA developed in 38 eyes (51%) during the mean of 4.7 ± 1.2 years of follow-up. Compared with eyes without SDD, those with SDD at baseline were 3.0 times (95% confidence interval [CI] 1.1–8.5, P = 0.0343) more likely to develop MA. Eyes with SDD present in the inferior macula and inferior extramacular fields at baseline were 3.0 times and 6.5 times more likely to develop MA at follow-up than eyes without SDD in these locations (95% CI 1.0–8.9, P = 0.0461 and 95% CI 1.3–32.4, P = 0.0218, respectively). MA development was not associated with a specific SDD phenotype. Conclusions MA frequently developed in eyes during anti-VEGF treatment. SDD were independently associated with MA development. The extension of SDD into the inferior fundus, particularly in the inferior extramacular field, conferred higher odds of subsequent MA development. PMID:29196768
Zeng, Yanni; Navarro, Pau; Xia, Charley; Amador, Carmen; Fernandez-Pujals, Ana M; Thomson, Pippa A; Campbell, Archie; Nagy, Reka; Clarke, Toni-Kim; Hafferty, Jonathan D; Smith, Blair H; Hocking, Lynne J; Padmanabhan, Sandosh; Hayward, Caroline; MacIntyre, Donald J; Porteous, David J; Haley, Chris S; McIntosh, Andrew M
2016-12-01
Both genetic and environmental factors contribute to risk of depression, but estimates of their relative contributions are limited. Commonalities between clinically-assessed major depressive disorder (MDD) and self-declared depression (SDD) are also unclear. Using data from a large Scottish family-based cohort (GS:SFHS, N=19,994), we estimated the genetic and environmental variance components for MDD and SDD. The components representing the genetic effect associated with genome-wide common genetic variants (SNP heritability), the additional pedigree-associated genetic effect and non-genetic effects associated with common environments were estimated in a linear mixed model (LMM). Both MDD and SDD had significant contributions from components representing the effect from common genetic variants, the additional genetic effect associated with the pedigree and the common environmental effect shared by couples. The estimate of correlation between SDD and MDD was high (r=1.00, se=0.20) for common-variant-associated genetic effect and lower for the additional genetic effect from the pedigree (r=0.57, se=0.08) and the couple-shared environmental effect (r=0.53, se=0.22). Both genetics and couple-shared environmental effects were major factors influencing liability to depression. SDD may provide a scalable alternative to MDD in studies seeking to identify common risk variants. Rarer variants and environmental effects may however differ substantially according to different definitions of depression. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Francis, Jill J; Duncan, Eilidh M; Prior, Maria E; Maclennan, Graeme S; Dombrowski, Stephan; Bellingan, Geoff U; Campbell, Marion K; Eccles, Martin P; Rose, Louise; Rowan, Kathryn M; Shulman, Rob; Peter R Wilson, A; Cuthbertson, Brian H
2014-04-01
Hospital-acquired infections (HAIs) are a major cause of morbidity and mortality. Critically ill patients in intensive care units (ICUs) are particularly susceptible to these infections. One intervention that has gained much attention in reducing HAIs is selective decontamination of the digestive tract (SDD). SDD involves the application of topical non-absorbable antibiotics to the oropharynx and stomach and a short course of intravenous (i.v.) antibiotics. SDD may reduce infections and improve mortality, but has not been widely adopted in the UK or internationally. Hence, there is a need to identify the reasons for low uptake and whether or not further clinical research is needed before wider implementation would be considered appropriate. The project objectives were to (1) identify and describe the SDD intervention, (2) identify views about the evidence base, (3) identify acceptability of further research and (4) identify feasibility of further randomised controlled trials (RCTs). A four-stage approach involving (1) case studies of two ICUs in which SDD is delivered including observations, interviews and documentary analysis, (2) a three-round Delphi study for in-depth investigation of clinicians' views, including semi-structured interviews and two iterations of questionnaires with structured feedback, (3) a nationwide online survey of consultants in intensive care medicine and clinical microbiology and (4) semistructured interviews with international clinical triallists to identify the feasibility of further research. Case studies were set in two UK ICUs. Other stages of this research were conducted by telephone and online with NHS staff working in ICUs. (1) Staff involved in SDD adoption or delivery in two UK ICUs, (2) ICU experts (intensive care consultants, clinical microbiologists, hospital pharmacists and ICU clinical leads), (3) all intensive care consultants and clinical microbiologists in the UK with responsibility for patients in ICUs were invited and (4) international triallists, selected from their research profiles in intensive care, clinical trials and/or implementation trials. SDD involves the application of topical non-absorbable antibiotics to the oropharynx and stomach and a short course of i.v. antibiotics. Levels of support for, or opposition to, SDD in UK ICUs; views about the SDD evidence base and about barriers to implementation; and feasibility of further SDD research (e.g. likely participation rates). (1) The two case studies identified complexity in the interplay of clinical and behavioural components of SDD, involving multiple staff. However, from the perspective of individual staff, delivery of SDD was regarded as simple and straightforward. (2) The Delphi study (n = 42) identified (a) specific barriers to SDD implementation, (b) uncertainty about the evidence base and (c) bimodal distributions for key variables, e.g. support for, or opposition to, SDD. (3) The national survey (n = 468) identified uncertainty about the effect of SDD on antimicrobial resistance, infection rates, mortality and cost-effectiveness. Most participants would participate in further SDD research. (4) The triallist interviews (n = 10) focused largely on the substantial challenges of conducting a large, multinational clinical effectiveness trial. There was considerable uncertainty about possible benefits and harms of SDD. Further large-scale clinical effectiveness trials of SDD in ICUs may be required to address these uncertainties, especially relating to antimicrobial resistance. There was a general willingness to participate in a future effectiveness RCT of SDD. However, support was not unanimous. Future research should address the barriers to acceptance and participation in any trial. There was some, but a low level of, interest in adoption of SDD, or studies to encourage implementation of SDD into practice. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 18, No. 25. See the NIHR Journals Library website for further project information.
Oostdijk, Evelien A N; de Wit, G A; Bakker, Marina; de Smet, Anne Marie G A; Bonten, M J M
2013-03-05
To determine costs and effects of selective digestive tract decontamination (SDD) and selective oropharyngeal decontamination (SOD) as compared with standard care (ie, no SDD/SOD (SC)) from a healthcare perspective in Dutch Intensive Care Units (ICUs). A post hoc analysis of a previously performed cluster-randomised trial (NEJM 2009;360:20). 13 Dutch ICUs. Patients with ICU-stay of >48 h that received SDD (n=2045), SOD (n=1904) or SC (n=1990). SDD or SOD. Effects were based on hospital survival, expressed as crude Life Years Gained (cLYG). The incremental cost-effectiveness ratio (ICER) was calculated, with corresponding cost acceptability curves. Sensitivity analyses were performed for discount rates, costs of SDD, SOD and mechanical ventilation. Total costs per patient were €41 941 for SC (95% CI €40 184 to €43 698), €40 433 for SOD (95% CI €38 838 to €42 029) and €41 183 for SOD (95% CI €39 408 to €42 958). SOD and SDD resulted in crude LYG of +0.04 and +0.25, respectively, as compared with SC, implying that both SDD and SOD are dominant (ie, cheaper and more beneficial) over SC. In cost-effectiveness acceptability curves probabilities for cost-effectiveness, compared with standard care, ranged from 89% to 93% for SOD and from 63% to 72% for SDD, for acceptable costs for 1 LYG ranging from €0 to €20 000. Sensitivity analysis for mechanical ventilation and discount rates did not change interpretation. Yet, if costs of the topical component of SDD and SOD would increase 40-fold to €400/day and €40/day (maximum values based on free market prices in 2012), the estimated ICER as compared with SC for SDD would be €21 590 per LYG. SOD would remain cost-saving. SDD and SOD were both effective and cost-saving in Dutch ICUs.
You, Joyce H S; Li, Hong-Kiu; Ip, Margaret
2018-03-01
Clinical findings have shown effectiveness and safety of selective digestive decontamination (SDD) for eradication of carbapenem-resistant Enterobacteriaceae (CRE) in high-risk carriers. We aimed to evaluate the cost-effectiveness of SDD guided by CRE surveillance in the intensive care unit (ICU). Outcomes of surveillance-guided SDD (test-guided SDD) and no screening (control) in the ICU were compared by Markov model simulations. Model outcomes were CRE infection and mortality rates, direct costs, and quality-adjusted life year (QALY) loss. Model inputs were estimated from clinical literature. Sensitivity analyses were conducted to examine the robustness of base case results. Test-guided SDD reduced infection (4.8% vs 5.0%) and mortality (1.8% vs 2.1%) rates at a higher cost ($1,102 vs $1,074) than the control group in base case analysis, respectively. Incremental cost per QALY saved (incremental cost-effectiveness ratio [ICER]) by the test-guided SDD group was $557 per QALY. Probabilistic sensitivity analysis showed that test-guided SDD was effective in saving QALYs in 100% of 10,000 Monte Carlo simulations, and cost-saving 59.1% of time. The remaining 40.9% of simulations found SDD to be effective at an additional cost, with ICERs accepted as cost-effective per the willingness-to-pay threshold. Surveillance-guided SDD appears to be cost-effective in reducing CRE infection and mortality with QALYs saved. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Valla, Lisbeth; Wentzel-Larsen, Tore; Hofoss, Dag; Slinning, Kari
2015-12-17
Prevalence estimates on suspected developmental delays (SDD) in young infants are scarce and a necessary first step for planning an early intervention. We investigated the prevalence of SDD at 4, 6 and 12 months, in addition to associations of SDD with gender, prematurity and maternal education. This study is based on a Norwegian longitudinal sample of 1555 infants and their parents attending well-baby clinics for regular health check-ups. Moreover, parents completed the Norwegian translation of the Ages and Stages Questionnaires (ASQ) prior to the check-up, with a corrected gestational age being used to determine the time of administration for preterm infants. Scores ≤ the established cut-offs in one or more of the five development areas: communication, gross motor, fine motor, problem solving and personal-social, which defined SDD for an infant were reported. Chi-square tests were performed for associations between the selected factors and SDD. According to established Norwegian cut-off points, the overall prevalence of SDD in one or more areas was 7.0 % (10.3 % US cut-off) at 4 months, 5.7 % (12.3 % US cut-off) at 6 months and 6.1 % (10.3 % US cut-off) at 12 months. The highest prevalence of SDD was in the gross motor area at all three time points. A gestational age of < 37 weeks revealed a significant association with the communication SDD at 4 months, and with the fine motor and personal social SDD at 6 months. Gender was significantly associated with the fine motor and problem solving SDD at 4 months and personal- social SDD at 6 months: as more boys than girls were delayed. No significant associations were found between maternal education and the five developmental areas of the ASQ. Our findings indicate prevalence rates of SDD between 5.7 and 7.0 % in Norwegian infants between 4 and 12 months of age based on the Norwegian ASQ cut-off points (10.3-12.3 %, US cut-off points). During the first year of life, delay is most frequent within the gross motor area. Special attention should be paid to infants born prematurely, as well as to boys. Separate norms for boys and girls should be considered for the ASQ.
Veelo, Denise P; Bulut, Tomas; Dongelmans, Dave A; Korevaar, Johanna C; Spronk, Peter E; Schultz, Marcus J
2008-01-01
Tracheotomy is considered to be an independent risk factor for ventilator-associated pneumonia (VAP). Antimicrobial prophylaxis, in particular with coverage of Pseudomonas aeruginosa, is presently advocated. Selective decontamination of the digestive tract (SDD) aims to prevent VAP in critically ill patients, including those after tracheotomy. We determined the incidence and microbial spectrum of VAP after tracheotomy in a SDD-setting. Retrospective analysis of 231 tracheotomized patients during a 2-year period. Thirteen patients (5.6%) developed VAP. The median [IQR] day of onset was 8.0 [3.0-10.5] days after tracheotomy. The most predominant causative pathogen was Methicillin-sensitive Staphylococcus aureus (MSSA). Timing of tracheotomy was not different between patients developing VAP and those who did not. The type of tracheotomy (percutaneous or surgical, 84.6% versus 15.4%) had no significant influence on the incidence of VAP. The incidence of VAP after tracheotomy in a SDD-setting is low, with MSSA as the predominant causative pathogen. Accordingly, if antimicrobial prophylaxis is considered, it may be advisable to cover MSSA in an SDD-setting.
Kim, S E; Hwang, S Y; Jeong, M; Lee, Y; Lee, E R; Park, Y W; Ahn, J S; Kim, S; Seo, K
2016-02-01
Doxycycline is regarded as an effective treatment for periodontal inflammation. In humans, it has been shown that the long-term administration of a subantimicrobial dose of doxycycline (SDD) does not induce antimicrobial effects on the subgingival microflora and furthermore does not affect antimicrobial susceptibility. The present study was designed to evaluate the influence of oral administration of SDD on normal periodontal microflora and antimicrobial susceptibility in dogs. Experimental periodontitis was induced in 12 experimental dogs using a silk and wire-twisted ligature for 60 days. After the periodontitis induction period, the ligature was removed, and dental cleaning (subgingival and supragingival ultrasonic scaling) was performed. The dogs were randomly assigned to one of two groups: an SDD group with six dogs receiving 2 mg/kg PO once daily and a control group with six dogs receiving a placebo. At weeks 0, 4 and 8, clinical periodontal parameters were evaluated. After the clinical assessments, subgingival plaque was sampled and then cultured in an anaerobic system for one week, and the total anaerobes, Porphyromonas spp., Bacteroides spp. and Pasteurella spp. counts were investigated. Using the agar dilution method, the minimum bactericidal concentration of doxycycline was evaluated and the resistance for doxycycline was monitored during this experimental phase. The clinical periodontal status of the SDD group was significantly improved compared to the control group (P <0.05). Bacterial counts were not significantly different between the two experimental groups (P > 0.05), and antibacterial resistance was not established in the SDD group during the experimental periods (P <0.05). These results suggest that the once daily oral regimen of 2 mg/kg of doxycycline could serve as a SDD in dogs. Copyright © 2015 Elsevier Ltd. All rights reserved.
2018-01-01
Selective digestive decontamination (SDD, topical antibiotic regimens applied to the respiratory tract) appears effective for preventing ventilator associated pneumonia (VAP) in intensive care unit (ICU) patients. However, potential contextual effects of SDD on Staphylococcus aureus infections in the ICU remain unclear. The S. aureus ventilator associated pneumonia (S. aureus VAP), VAP overall and S. aureus bacteremia incidences within component (control and intervention) groups within 27 SDD studies were benchmarked against 115 observational groups. Component groups from 66 studies of various interventions other than SDD provided additional points of reference. In 27 SDD study control groups, the mean S. aureus VAP incidence is 9.6% (95% CI; 6.9–13.2) versus a benchmark derived from 115 observational groups being 4.8% (95% CI; 4.2–5.6). In nine SDD study control groups the mean S. aureus bacteremia incidence is 3.8% (95% CI; 2.1–5.7) versus a benchmark derived from 10 observational groups being 2.1% (95% CI; 1.1–4.1). The incidences of S. aureus VAP and S. aureus bacteremia within the control groups of SDD studies are each higher than literature derived benchmarks. Paradoxically, within the SDD intervention groups, the incidences of both S. aureus VAP and VAP overall are more similar to the benchmarks. PMID:29300363
Zhang, Yuhua; Wang, Xiaolin; Godara, Pooja; Zhang, Tianjiao; Clark, Mark E; Witherspoon, C Douglas; Spaide, Richard F; Owsley, Cynthia; Curcio, Christine A
2018-01-01
To investigate the natural history of dot subretinal drusenoid deposits (SDD) in age-related macular degeneration, using high-resolution adaptive optics scanning laser ophthalmoscopy. Six eyes of four patients with intermediate age-related macular degeneration were studied at baseline and 1 year later. Individual dot SDD within the central 30° retina were examined with adaptive optics scanning laser ophthalmoscopy and optical coherence tomography. A total of 269 solitary SDD were identified at baseline. Over 12.25 ± 1.18 months, all 35 Stage 1 SDD progressed to advanced stages. Eighteen (60%) Stage 2 lesions progressed to Stage 3 and 12 (40%) remained at Stage 2. Of 204 Stage 3 SDD, 12 (6.4%) disappeared and the rest remained. Twelve new SDD were identified, including 6 (50%) at Stage 1, 2 (16.7%) at Stage 2, and 4 (33.3%) at Stage 3. The mean percentage of the retina affected by dot SDD, measured by the adaptive optics scanning laser ophthalmoscopy, increased in 5/6 eyes (from 2.31% to 5.08% in the most changed eye) and decreased slightly in 1/6 eye (from 10.67% to 10.54%). Dynamism, the absolute value of the areas affected by new and regressed lesions, ranged from 0.7% to 9.3%. Adaptive optics scanning laser ophthalmoscopy reveals that dot SDD, like drusen, are dynamic.
van der Voort, P H J; van Roon, E N; Kampinga, G A; Boerma, E C; Gerritsen, R Th; Egbers, P H M; Kuiper, M A
2004-10-01
We compared standard antibiotic use with an antibiotic policy based on selective decontamination of the digestive tract (SDD) for cost and microbiology. A 2-year before-after observational study was performed in an 11-bed, mixed medical and surgical intensive care unit (ICU). We included all consecutive patients admitted to the ICU 1 year before and 1 year after institution of SDD (patients admitted within the 2-month SDD run-in period were excluded from analysis). In the year before SDD, 513 patients were treated in the ICU (mean APACHE II 19.5), compared to 529 in the year with SDD (mean APACHE II 19.4). The duration of mechanical ventilation was shorter in the SDD-treated patients (median 3, interquartile range [IQR] 2-7 days vs median 4 days, IQR 2-10, p = 0.03). The total of ICU variable costs, microbiological costs and antibiotic costs were equal in both episodes: euro 1,171 versus euro 1,168 per patient). Aerobic gram-negative bacilli (AGNB) and multiresistant AGNB were found less frequently in SDD-treated patients, RR 0.37 (95% CI 0.33-0.42) and RR 0.28 (95% CI 0.19-0.42). Multi-resistant AGNB in tracheal secretions and urine more than 72 hours after admission were completely absent in SDD-treated patients. The overall cost per patient treated during an antibiotic policy including SDD was equal to a policy supporting standard antibiotic care. In addition, duration of ventilation decreased and a trend was shown towards a decreased Length of ICU and hospital stay. Less frequently, cultures from organ sites containing AGNB were found during SDD and the number of multi-resistant strains was significantly reduced at organ sites, in particular trachea and urine. Fewer patients were colonized with multi-resistant AGNB but these numbers did not reach statistical significance.
Buelow, Elena; Bello González, Teresita D J; Fuentes, Susana; de Steenhuijsen Piters, Wouter A A; Lahti, Leo; Bayjanov, Jumamurat R; Majoor, Eline A M; Braat, Johanna C; van Mourik, Maaike S M; Oostdijk, Evelien A N; Willems, Rob J L; Bonten, Marc J M; van Passel, Mark W J; Smidt, Hauke; van Schaik, Willem
2017-08-14
The gut microbiota is a reservoir of opportunistic pathogens that can cause life-threatening infections in critically ill patients during their stay in an intensive care unit (ICU). To suppress gut colonization with opportunistic pathogens, a prophylactic antibiotic regimen, termed "selective decontamination of the digestive tract" (SDD), is used in some countries where it improves clinical outcome in ICU patients. Yet, the impact of ICU hospitalization and SDD on the gut microbiota remains largely unknown. Here, we characterize the composition of the gut microbiota and its antimicrobial resistance genes ("the resistome") of ICU patients during SDD and of healthy subjects. From ten patients that were acutely admitted to the ICU, 30 fecal samples were collected during ICU stay. Additionally, feces were collected from five of these patients after transfer to a medium-care ward and cessation of SDD. Feces from ten healthy subjects were collected twice, with a 1-year interval. Gut microbiota and resistome composition were determined using 16S rRNA gene phylogenetic profiling and nanolitre-scale quantitative PCRs. The microbiota of the ICU patients differed from the microbiota of healthy subjects and was characterized by lower microbial diversity, decreased levels of Escherichia coli and of anaerobic Gram-positive, butyrate-producing bacteria of the Clostridium clusters IV and XIVa, and an increased abundance of Bacteroidetes and enterococci. Four resistance genes (aac(6')-Ii, ermC, qacA, tetQ), providing resistance to aminoglycosides, macrolides, disinfectants, and tetracyclines, respectively, were significantly more abundant among ICU patients than in healthy subjects, while a chloramphenicol resistance gene (catA) and a tetracycline resistance gene (tetW) were more abundant in healthy subjects. The gut microbiota of SDD-treated ICU patients deviated strongly from the gut microbiota of healthy subjects. The negative effects on the resistome were limited to selection for four resistance genes. While it was not possible to disentangle the effects of SDD from confounding variables in the patient cohort, our data suggest that the risks associated with ICU hospitalization and SDD on selection for antibiotic resistance are limited. However, we found evidence indicating that recolonization of the gut by antibiotic-resistant bacteria may occur upon ICU discharge and cessation of SDD.
Chen, Yuejie; Wang, Shujing; Wang, Shan; Liu, Chengyu; Su, Ching; Hageman, Michael; Hussain, Munir; Haskell, Roy; Stefanski, Kevin; Qian, Feng
2016-10-01
To identify the key formulation factors controlling the initial drug and polymer dissolution rates from an amorphous solid dispersion (ASD). Ketoconazole (KTZ) ASDs using PVP, PVP-VA, HMPC, or HPMC-AS as polymeric matrix were prepared. For each drug-polymer system, two types of formulations with the same composition were prepared: 1. Spray dried dispersion (SDD) that is homogenous at molecular level, 2. Physical blend of SDD (80% drug loading) and pure polymer (SDD-PB) that is homogenous only at powder level. Flory-Huggins interaction parameters (χ) between KTZ and the four polymers were obtained by Flory-Huggins model fitting. Solution (13)C NMR and FT-IR were conducted to investigate the specific drug-polymer interaction in the solution and solid state, respectively. Intrinsic dissolution of both the drug and the polymer from ASDs were studied using a Higuchi style intrinsic dissolution apparatus. PXRD and confocal Raman microscopy were used to confirm the absence of drug crystallinity on the tablet surface before and after dissolution study. In solid state, KTZ is completely miscible with PVP, PVP-VA, or HPMC-AS, demonstrated by the negative χ values of -0.36, -0.46, -1.68, respectively; while is poorly miscible with HPMC shown by a positive χ value of 0.23. According to solution (13)C NMR and FT-IR studies, KTZ interacts with HPMC-AS strongly through H-bonding and dipole induced interaction; with PVPs and PVP-VA moderately through dipole-induced interactions; and with HPMC weakly without detectable attractive interaction. Furthermore, the "apparent" strength of drug-polymer interaction, measured by the extent of peak shift on NMR or FT-IR spectra, increases with the increasing number of interacting drug-polymer pairs. For ASDs with the presence of considerable drug-polymer interactions, such as KTZ/PVPs, KTZ/PVP-VA, or KTZ /HPMC-AS systems, drug released at the same rate as the polymer when intimate drug-polymer mixing was ensured (i.e., the SDD systems); while drug released much slower than the polymer when molecular level mixing or drug-polymer interaction was absent (SDD-PB systems). For ASDs without drug-polymer interaction (i.e., KTZ/HPMC systems), the mixing homogeneity had little impact on the release rate of either the drug or the polymer thus SDD and SDD-PB demonstrated the same drug or polymer release rate, while the drug released slowly and independently of polymer release. The initial drug release from an ASD was controlled by 1) the polymer release rate; 2) the strength of drug-polymer interaction, including the intrinsic interaction caused by the chemistry of the drug and the polymer (measured by the χ value), as well as that the apparent interaction caused by the drug-polymer ratio (measure by the extent of peak shift on spectroscopic analysis); and 3) the level of mixing homogeneity between the drug and polymer. In summary, the selection of polymer, drug-polymer ratio, and ASD processing conditions have profound impacts on the dissolution behavior of ASDs. Graphical Abstract Relationship between initial drug and polymer dissolution rates from amorphous solid dispersions with different mixing uniformity and drug-polymer interactions.
Ultrasound sensitivity to changes in gout: a longitudinal study after two years of treatment.
Peiteado, Diana; Villalba, Alejandro; Martín-Mola, Emilio; Balsa, Alejandro; De Miguel, Eugenio
2017-01-01
The goals of our study are to evaluate the urate-lowering therapy (ULT) effect on gout ultrasound (US) lesions and to explore US sensitivity to change in gout patients. Patients with chronic and symptomatic gout, confirmed by crystal identification, were prospectively included. Clinical and US assessments were performed at baseline and after 6, 12 and 24 months of ULT. The presence of double contour sign (DCS) and US- detectable tophi were assessed in the first metatarsophalangeals, the knees and patellar tendons. The mean and standard deviation were calculated for each parameter. The correlation between the clinical and US parameters was assessed by calculating Pearson's correlation coefficient. Sensitivity to change in the US examinations was assessed by estimating the smallest detectable difference (SDD). Twenty-three consecutive patients were included (96% men; mean age 59 ± 11 years). DCS and US tophi were detected in 73.9% and 91.3% of patients at baseline. A significant parallel improvement in the serum urate, clinical parameters and US lesions was found at the follow-up assessment. The SDD values for the global DCS and tophi were 0.52 and 0.69, respectively, which were smaller than the differences achieved over the course of the two years. A significant correlation between DCS and clinical parameters was observed (r =0.49, p=0.038). Ultrasound findings in gout patients show sensitivity to change and concurrent validity with uric acid reduction after ULT in gout patients. US can be a useful tool for gout tophus burden monitoring.
NASA Astrophysics Data System (ADS)
Shi, Kun; Zhang, Yunlin; Zhu, Guangwei; Qin, Boqiang; Pan, Delu
2018-06-01
Water clarity (Secchi disk depth: SDD), as a proxy of water transparency, provides important information on the light availability to the water or lake ecosystem. Shallow lakes have been experienced dramatic environmental and climatic change. This study demonstrated using combination of long-term MODIS and in-situ measurements to track the dynamics of SDD with these environmental and climate changes in shallow water environments. We selected a typical turbid shallow Lake Taihu as our case study. Based on MODIS-Aqua data, an empirical model for estimating SDD was developed and validated. Subsequently, we employed the proposed model to derive the spatial and temporal SDD distribution patterns of Lake Taihu from 2003 to 2015. Combining MODIS-derived SDD time series of 2003-2015 and long-term in-situ SDD observations dated back to 1993, we elucidated SDD long-term variation trends and driving mechanism. Deteriorating water clarity from the long-term SDD observations indicated that Lake Taihu became more and more turbid and water quality was decreasing. Increasing in cyanobacterial bloom area, as a result of decreasing in wind speed and eutrophication, may partially be responsible for the decreasing trend. A predicted future decrease in the wind speed in Lake Taihu region could enhance the formation of cyanobacterial blooms and consequently lead to a further decrease in water clarity. This study suggested that coupling remote sensing monitoring and long-term in-situ observations could provide robust evidence and new insights to elucidate long-term dynamics in aquatic ecosystem evolution.
Burghardt, Andrew J; Lee, Chan Hee; Kuo, Daniel; Majumdar, Sharmila; Imboden, John B; Link, Thomas M; Li, Xiaojuan
2013-12-01
In this technique development study, high-resolution peripheral quantitative computed tomography (HR-pQCT) was applied to non-invasively image and quantify 3D joint space morphology of the wrist and metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA). HR-pQCT imaging (82 μm voxel-size) of the dominant hand was performed in patients with diagnosed rheumatoid arthritis (RA, N = 16, age: 52.6 ± 12.8) and healthy controls (CTRL, N = 7, age: 50.1 ± 15.0). An automated computer algorithm was developed to segment wrist and MCP joint spaces. The 3D distance transformation method was applied to spatially map joint space width, and summarized by the mean joint space width (JSW), minimal and maximal JSW (JSW.MIN, JSW.MAX), asymmetry (JSW.AS), and distribution (JSW.SD)-a measure of joint space heterogeneity. In vivo precision was determined for each measure by calculating the smallest detectable difference (SDD) and root mean square coefficient of variation (RMSCV%) of repeat scans. Qualitatively, HR-pQCT images and pseudo-color JSW maps showed global joint space narrowing, as well as regional and focal abnormalities in RA patients. In patients with radiographic JSN at an MCP, JSW.SD was two-fold greater vs. CTRL (p < 0.01), and JSW.MIN was more than two-fold lower (p < 0.001). Similarly, JSW.SD was significantly greater in the wrist of RA patients vs. CTRL (p < 0.05). In vivo precision was highest for JSW (SDD: 100 μm, RMSCV: 2.1%) while the SDD for JSW.MIN and JSW.SD were 370 and 110 μm, respectively. This study suggests that in vivo quantification of 3D joint space morphology from HR-pQCT, could improve early detection of joint damage in rheumatological diseases.
Burghardt, Andrew J.; Lee, Chan Hee; Kuo, Daniel; Majumdar, Sharmila; Imboden, John B.; Link, Thomas M.; Li, Xiaojuan
2013-01-01
In this technique development study, high-resolution peripheral quantitative computed tomography (HR-pQCT) was applied to non-invasively image and quantify 3D joint space morphology of the wrist and metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA). HR-pQCT imaging (82μm voxel-size) of the dominant hand was performed in patients with diagnosed rheumatoid arthritis (RA, N=16, age:52.6±12.8) and healthy controls (CTRL, N=7, age:50.1±15.0). An automated computer algorithm was developed to segment wrist and MCP joint spaces. The 3D distance transformation method was applied to spatially map joint space width, and summarized by the mean joint space width (JSW), minimal and maximal JSW (JSW.MIN, JSW.MAX), asymmetry (JSW.AS), and distribution (JSW.SD) – a measure of joint space heterogeneity. In vivo precision was determined for each measure by calculating the smallest detectable difference (SDD) and root mean square coefficient of variation (RMSCV%) of repeat scans. Qualitatively, HR-pQCT images and pseudo-color JSW maps showed global joint space narrowing, as well as regional and focal abnormalities in RA patients. In patients with radiographic JSN at an MCP, JSW.SD was two-fold greater versus CTRL (p<0.01), and JSW.MIN was more than two-fold lower (p<0.001). Similarly, JSW.SD was significantly greater in the wrist of RA patients versus CTRL (p<0.05). In vivo precision was highest for JSW (SDD: 100μm, RMSCV: 2.1%) while the SDD for JSW.MIN and JSW.SD were 370 and 110μm, respectively. This study suggests that in vivo quantification of 3D joint space morphology from HR-pQCT, could improve early detection of joint damage in rheumatological diseases. PMID:23887879
Thirty-minute compared to standardised office blood pressure measurement in general practice
Scherpbier-de Haan, Nynke; van der Wel, Mark; Schoenmakers, Gijs; Boudewijns, Steve; Peer, Petronella; van Weel, Chris; Thien, Theo; Bakx, Carel
2011-01-01
Background Although blood pressure measurement is one of the most frequently performed measurements in clinical practice, there are concerns about its reliability. Serial, automated oscillometric blood pressure measurement has the potential to reduce measurement bias and white-coat effect' Aim To study agreement of 30-minute office blood pressure measurement (OBPM) with standardised OBPM, and to compare repeatability Design and setting Method comparison study in two general practices in the Netherlands Method Thirty-minute and standardised OBPM was carried out with the same, validated device in 83 adult patients, and the procedure was repeated after 2 weeks. During 30-minute OBPM, blood pressure was measured automatically every 3 minutes, with the patient in a sitting position, alone in a quiet room. Agreement between 30-minute and standardised OBPM was assessed by Bland–Altman analysis. Repeatability of the blood pressure measurement methods after 2 weeks was expressed as the mean difference in combination with the standard deviation of difference (SDD) Results Mean 30-minute OBPM readings were 7.6/2.5 mmHg (95% confidence interval [CI] = 6.1 to 9.1/1.5 to 3.4 mmHg) lower than standardised OBPM readings. The mean difference and SDD between repeated 30-minute OBPMs (mean difference = 3/1 mmHg, 95% CI = 1 to 5/0 to 2 mmHg; SDD 9.5/5.3 mmHg) were lower than those of standardised OBPMs (mean difference = 6/2 mmHg, 95% CI = 4 to 8/1 to 4 mmHg; SDD 10.9/6.3 mmHg). Conclusion Thirty-minute OBPM resulted in lower readings than standardised OBPM and had a better repeatability. These results suggest that 30-minute OBPM better reflects the patient's true blood pressure than standardised OBPM does. PMID:22152748
MiKlip-PRODEF: Probabilistic Decadal Forecast for Central and Western Europe
NASA Astrophysics Data System (ADS)
Reyers, Mark; Haas, Rabea; Ludwig, Patrick; Pinto, Joaquim
2013-04-01
The demand for skilful climate predictions on time-scales of several years to decades has increased in recent years, in particular for economic, societal and political terms. Within the BMBF MiKlip consortium, a decadal prediction system on the global to local scale is currently being developed. The subproject PRODEF is part of the MiKlip-Module C, which aims at the regionalisation of decadal predictability for Central and Western Europe. In PRODEF, a combined statistical-dynamical downscaling (SDD) and a probabilistic forecast tool are developed and applied to the new Earth system model of the Max-Planck Institute Hamburg (MPI-ESM), which is part of the CMIP5 experiment. Focus is given on the decadal predictability of windstorms, related wind gusts as well as wind energy potentials. SDD combines the benefits of both high resolution dynamical downscaling and purely statistical downscaling of GCM output. Hence, the SDD approach is used to obtain a very large ensemble of highly resolved decadal forecasts. With respect to the focal points of PRODEF, a clustering of temporal evolving atmospheric fields, a circulation weather type (CWT) analysis, and a storm damage indices analysis is applied to the full ensemble of the decadal hindcast experiments of the MPI-ESM in its lower resolution (MPI-ESM-LR). The ensemble consists of up to ten realisations per yearly initialised decadal hindcast experiments for the period 1960-2010 (altogether 287 realisations). Representatives of CWTs / clusters and single storm episodes are dynamical downscaled with the regional climate model COSMO-CLM with a horizontal resolution of 0.22°. For each model grid point, the distributions of the local climate parameters (e.g. surface wind gusts) are determined for different periods (e.g. each decades) by recombining dynamical downscaled episodes weighted with the respective weather type frequencies. The applicability of the SDD approach is illustrated with examples of decadal forecasts of the MPI-ESM. We are able to perform a bias correction of the frequencies of large scale weather types and to quantify the uncertainties of decadal predictability on large and local scale arising from different initial conditions. Further, probability density functions of local parameters like e.g. wind gusts for different periods and decades derived from the SDD approach is compared to observations and reanalysis data. Skill scores are used to quantify the decadal predictability for different leading time periods and to analyse whether the SDD approach shows systematic errors for some regions.
Rating scales for dystonia in cerebral palsy: reliability and validity.
Monbaliu, E; Ortibus, E; Roelens, F; Desloovere, K; Deklerck, J; Prinzie, P; de Cock, P; Feys, H
2010-06-01
This study investigated the reliability and validity of the Barry-Albright Dystonia Scale (BADS), the Burke-Fahn-Marsden Movement Scale (BFMMS), and the Unified Dystonia Rating Scale (UDRS) in patients with bilateral dystonic cerebral palsy (CP). Three raters independently scored videotapes of 10 patients (five males, five females; mean age 13 y 3 mo, SD 5 y 2 mo, range 5-22 y). One patient each was classified at levels I-IV in the Gross Motor Function Classification System and six patients were classified at level V. Reliability was measured by (1) intraclass correlation coefficient (ICC) for interrater reliability, (2) standard error of measurement (SEM) and smallest detectable difference (SDD), and (3) Cronbach's alpha for internal consistency. Validity was assessed by Pearson's correlations among the three scales used and by content analysis. Moderate to good interrater reliability was found for total scores of the three scales (ICC: BADS=0.87; BFMMS=0.86; UDRS=0.79). However, many subitems showed low reliability, in particular for the UDRS. SEM and SDD were respectively 6.36% and 17.72% for the BADS, 9.88% and 27.39% for the BFMMS, and 8.89% and 24.63% for the UDRS. High internal consistency was found. Pearson's correlations were high. Content validity showed insufficient accordance with the new CP definition and classification. Our results support the internal consistency and concurrent validity of the scales; however, taking into consideration the limitations in reliability, including the large SDD values and the content validity, further research on methods of assessment of dystonia is warranted.
Effects of selective digestive decontamination (SDD) on the gut resistome.
Buelow, Elena; Gonzalez, Teresita Bello; Versluis, Dennis; Oostdijk, Evelien A N; Ogilvie, Lesley A; van Mourik, Maaike S M; Oosterink, Els; van Passel, Mark W J; Smidt, Hauke; D'Andrea, Marco Maria; de Been, Mark; Jones, Brian V; Willems, Rob J L; Bonten, Marc J M; van Schaik, Willem
2014-08-01
Selective digestive decontamination (SDD) is an infection prevention measure for critically ill patients in intensive care units (ICUs) that aims to eradicate opportunistic pathogens from the oropharynx and intestines, while sparing the anaerobic flora, by the application of non-absorbable antibiotics. Selection for antibiotic-resistant bacteria is still a major concern for SDD. We therefore studied the impact of SDD on the reservoir of antibiotic resistance genes (i.e. the resistome) by culture-independent approaches. We evaluated the impact of SDD on the gut microbiota and resistome in a single ICU patient during and after an ICU stay by several metagenomic approaches. We also determined by quantitative PCR the relative abundance of two common aminoglycoside resistance genes in longitudinally collected samples from 12 additional ICU patients who received SDD. The patient microbiota was highly dynamic during the hospital stay. The abundance of antibiotic resistance genes more than doubled during SDD use, mainly due to a 6.7-fold increase in aminoglycoside resistance genes, in particular aph(2″)-Ib and an aadE-like gene. We show that aph(2″)-Ib is harboured by anaerobic gut commensals and is associated with mobile genetic elements. In longitudinal samples of 12 ICU patients, the dynamics of these two genes ranged from a ∼10(4) fold increase to a ∼10(-10) fold decrease in relative abundance during SDD. ICU hospitalization and the simultaneous application of SDD has large, but highly individualized, effects on the gut resistome of ICU patients. Selection for transferable antibiotic resistance genes in anaerobic commensal bacteria could impact the risk of transfer of antibiotic resistance genes to opportunistic pathogens. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
The Quality of Life of Children with Severe Developmental Disabilities
ERIC Educational Resources Information Center
Ncube, B. L.; Perry, A.; Weiss, J. A.
2018-01-01
Background: Research examining the quality of life (QoL) of children with severe developmental disabilities (SDD) is limited. The present study examines parent perceptions of child QoL in children with SDD compared with typically developing (TD) children and then examines predictors of QoL for the SDD group. Method: Parents of 246 children with…
Reliability and Validity of the IKDC, KOOS, and WOMAC for Patients With Meniscal Injuries.
van de Graaf, Victor A; Wolterbeek, Nienke; Scholtes, Vanessa A B; Mutsaerts, Eduard L A R; Poolman, Rudolf W
2014-06-01
Several patient-reported outcome measurements are used to measure functional outcome after treatment of meniscal injuries. However, for comparison of study results, there is a need for a uniform and standardized approach of measuring functional outcome. Selection of the instrument should be based on the quality of its measurement properties, and only the best instrument can be justified to be used. This study aimed to determine and compare the measurement properties of the Dutch-language versions of the International Knee Documentation Committee (IKDC) Subjective Knee Form, Knee Injury and Osteoarthritis Outcome Score (KOOS), and Western Ontario and McMaster Universities Arthritis Index (WOMAC) in a homogeneous group of patients with meniscal tears. Cohort study (design); Level of evidence, 2. Patients on the waiting list for meniscal surgery and patients between 6 weeks and 6 months after meniscal surgery were included (n = 75). Patients were excluded if they received an arthroplasty or had surgery on the anterior cruciate ligament. Internal consistency (Cronbach alpha), test-retest reliability (intraclass correlation coefficient [ICC]), measurement error (SEM), smallest detectable difference (SDD), content validity, construct validity (factor analysis and hypothesis testing), and floor and ceiling effects were determined. Results for the IKDC, KOOS dimensions, and WOMAC dimensions, respectively, were as follows: Cronbach alpha = .90, .72-.95, and .84-.95; ICC = 0.93, 0.84-0.89, and 0.77-0.89; SEM = 5.3, 7.0-12.6, and 7.3-12.2; SDD = 14.6, 19.4-35.0, and 20.2-33.9; hypotheses testing confirmation = 100%, 86%, and 85%. Floor effects within the SDD from the minimum score were found for the KOOS Sports/Recreation and Quality of Life dimensions. Ceiling effects within the SDD from the maximum score were found for the KOOS Activities of Daily Living and for all WOMAC dimensions. The IKDC showed the best performance on all measurement properties, implying that the IKDC, rather than the KOOS or WOMAC, should be used to assess functional outcome in patients with meniscal tears. © 2014 The Author(s).
ERIC Educational Resources Information Center
Carter, Rebecca R.; Johnson, Shannon M.; Exline, Julie J.; Post, Stephen G.; Pagano, Maria E.
2012-01-01
The purpose of this study is to explore narcissistic and prosocial behaviors as reported by adolescents with and without substance dependency disorder (SDD). This study employs a quasi-experimental design using SDD adolescents compared with two normative samples of adolescents. In comparison to normative adolescents, adolescents with SDD were…
CARTER, REBECCA R.; JOHNSON, SHANNON M.; EXLINE, JULIE J.; POST, STEPHEN G.; PAGANO, MARIA E.
2012-01-01
The purpose of this study is to explore narcissistic and prosocial behaviors as reported by adolescents with and without substance dependency disorder (SDD). This study employs a quasi-experimental design using SDD adolescents compared with two normative samples of adolescents. In comparison to normative adolescents, adolescents with SDD were strongly distinguished by overt narcissistic behaviors and less monetary giving. Levels of narcissistic and prosocial behaviors among adolescents with SDD suggest a connection between self-centeredness and addiction. Results also suggest volunteerism as a potential option to counter narcissism in substance dependent adolescents. PMID:22544995
For whom should we use selective decontamination of the digestive tract?
de Smet, Anne Marie G A; Bonten, Marc J M; Kluytmans, Jan A J W
2012-04-01
This review discusses the relevant studies on selective decontamination of the digestive tract (SDD) published between 2009 and mid-2011. In a multicenter cluster-randomized cross-over study in the Netherlands, SDD and selective oropharyngeal decontamination (SOD) were associated with higher survival at day 28, with a lower incidence of ICU-acquired bacteremia and with less acquisition of respiratory tract colonization with antibiotic resistant pathogens, compared to standard care. A post-hoc analysis of this study suggests that SDD might be more effective in surgical patients and SOD in nonsurgical patients. In a randomized study perioperative use of SDD in patients undergoing gastrointestinal surgery was associated with lower incidences of anastomotic leakages. A Cochrane meta-analysis, not including any of the before mentioned studies, reported a reduction of respiratory tract infections in studies by using topical antibiotics only and higher survival rates when topical antibiotics were combined with parenteral antibiotics. Recent studies show that in ICUs with low levels of antibiotic resistance, SDD and SOD improved patient outcome and reduced infections and carriage with antibiotic-resistant pathogens. The effect in settings with higher levels of antibiotic resistance remains to be determined as well as the efficacy of SDD and SOD in specific patient groups.
NASA Astrophysics Data System (ADS)
Avci, Onur; Abdeljaber, Osama; Kiranyaz, Serkan; Hussein, Mohammed; Inman, Daniel J.
2018-06-01
Being an alternative to conventional wired sensors, wireless sensor networks (WSNs) are extensively used in Structural Health Monitoring (SHM) applications. Most of the Structural Damage Detection (SDD) approaches available in the SHM literature are centralized as they require transferring data from all sensors within the network to a single processing unit to evaluate the structural condition. These methods are found predominantly feasible for wired SHM systems; however, transmission and synchronization of huge data sets in WSNs has been found to be arduous. As such, the application of centralized methods with WSNs has been a challenge for engineers. In this paper, the authors are presenting a novel application of 1D Convolutional Neural Networks (1D CNNs) on WSNs for SDD purposes. The SDD is successfully performed completely wireless and real-time under ambient conditions. As a result of this, a decentralized damage detection method suitable for wireless SHM systems is proposed. The proposed method is based on 1D CNNs and it involves training an individual 1D CNN for each wireless sensor in the network in a format where each CNN is assigned to process the locally-available data only, eliminating the need for data transmission and synchronization. The proposed damage detection method operates directly on the raw ambient vibration condition signals without any filtering or preprocessing. Moreover, the proposed approach requires minimal computational time and power since 1D CNNs merge both feature extraction and classification tasks into a single learning block. This ability is prevailingly cost-effective and evidently practical in WSNs considering the hardware systems have been occasionally reported to suffer from limited power supply in these networks. To display the capability and verify the success of the proposed method, large-scale experiments conducted on a laboratory structure equipped with a state-of-the-art WSN are reported.
Bolster, Eline A M; Dallmeijer, Annet J; de Wolf, G Sander; Versteegt, Marieke; Schie, Petra E M van
2017-05-01
To determine the test-retest reliability and construct validity of a novel 6-Minute Racerunner Test (6MRT) in children and youth with cerebral palsy (CP) classified as Gross Motor Function Classification System (GMFCS) levels III and IV. The racerunner is a step-propelled tricycle. The participants were 38 children and youth with CP (mean age 11 y 2 m, SD 3 y 7 m; GMFCS III, n = 19; IV, n = 19). Racerunner capability was determined as the distance covered during the 6MRT on three occasions. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable differences (SDD) were calculated to assess test-retest reliability. The ICC for tests 2 and 3 were 0.89 (SDD 37%; 147 m) for children in level III and 0.91 for children in level IV (SDD 52%; 118 m). When the average of two separate test occasions was used, the SDDs were reduced to 26% (104 m; level III) and 37% (118 m; level IV). For tests 1 to 3, the mean distance covered increased from 345 m (SD 148 m) to 413 m (SD 137 m) for children in level III, and from 193 m (SD 100 m) to 239 m (SD 148 m) for children in level IV. Results suggest high test-retest reliability. However, large SDDs indicate that a single 6MRT measurement is only useful for individual evaluation when large improvements are expected, or when taking the average of two tests. The 6MRT discriminated the distance covered between children and youth in levels III and IV, supporting construct validity.
Motyl, Jillian M; Driban, Jeffrey B; McAdams, Erica; Price, Lori Lyn; McAlindon, Timothy E
2013-05-10
The 20-meter walk test is a physical function measure commonly used in clinical research studies and rehabilitation clinics to measure gait speed and monitor changes in patients' physical function over time. Unfortunately, the reliability and sensitivity of this walk test are not well defined and, therefore, limit our ability to evaluate real changes in gait speed not attributable to normal variability. The aim of this study was to assess the test-restest reliability and sensitivity of the 20-meter walk test, at a self-selected pace, among patients with mild to moderate knee osteoarthritis (OA) and to suggest a standardized protocol for future test administration. This was a measurement reliability study. Fifteen consecutive people enrolled in a randomized-controlled trial of intra-articular corticosteroid injections for knee OA participated in this study. All participants completed 4 trials on 2 separate days, 7 to 21 days apart (8 trials total). Each day was divided into 2 sessions, which each involved 2 walking trials. We compared walk times between trials with Wilcoxon signed-rank tests. Similar analyses compared average walk times between sessions. To confirm these analyses, we also calculated Spearman correlation coefficients to assess the relationship between sessions. Finally, smallest detectable differences (SDD) were calculated to estimate the sensitivity of the 20-meter walk test. Wilcoxon signed-rank tests between trials within the same session demonstrated that trials in session 1 were significantly different and in the subsequent 3 sessions, the median differences between trials were not significantly different. Therefore, the first session of each day was considered a practice session, and the SDD between the second session of each day were calculated. SDD was -1.59 seconds (walking slower) and 0.15 seconds (walking faster). Practice trials and a standardized protocol should be used in administration of the 20-meter walk test. Changes in walk time between -1.59 seconds (walking slower) and 0.15 seconds (walking faster) should be considered within the range of normal variability of 20-meter walking speed. The primary limitation of our study was a small sample size, which may influence the generalizability of our findings.
1991-04-21
COMMENT: YES [ ] NO [ ] ERCI ACCEPTS COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ I CLOSED [ ] ORIGINATOR CONTROL NUMBER: SDD-0002...ERCI ACCEPTS COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION: COMMENT STATUS! OPEN [ ] CLOSED [ ] ORIGINATOR CONTROL NUMBER: SDD-0003 PROGRAM OFFICE CONTROL...COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ ] CLOSED [ ] ORIGINATOR CONTROL NUMBER: SDD-0004 PROGPLAM OFFICE CONTROL NUMBER
2011-01-01
Introduction Mechanically ventilated critically ill patients frequently develop ventilator-associated pneumonia (VAP), a life-threatening complication. Proposed preventive measures against VAP include, but are not restricted to, selective decontamination of the digestive tract (SDD), selective oropharyngeal decontamination (SOD) and the use of probiotics. Probiotics are live bacteria that could have beneficial effects on the host by altering gastrointestinal flora. Similar to SDD and SOD, a prescription of probiotics aims at the prevention of secondary colonization of the upper and/or lower digestive tract. Methods We performed a literature review to describe the differences and similarities between SDD/SOD and probiotic preventive strategies, focusing on (a) efficacy, (b) risks, and (c) the routing of these strategies. Results Reductions in the incidence of VAP have been achieved with SDD and SOD. Two large randomized controlled trials even showed reduced mortality with these preventive strategies. Randomized controlled trials of probiotic strategies also showed a reduction of the incidence of VAP, but trials were too small to draw firm conclusions. Preventive strategies with antibiotics and probiotics may be limited due to the risk of emerging resistance to the locally applied antibiotics and the risk of probiotic-related infections, respectively. The majority of trials of SDD and SOD did not exhaustively address the issue of emerging resistance. Likewise, trials of probiotic strategies did not adequately address the risk of colonization with probiotics and probiotic-related infection. In studies of SDD and SOD the preventive strategy aimed at decontamination of the oral cavity, throat, stomach and intestines, and the oral cavity and throat, respectively. In the vast majority of studies of probiotic therapy the preventive strategy aimed at decontamination of the stomach and intestines. Conclusions Prophylactic use of antibiotics in critically ill patients is effective in reducing the incidence of VAP. Probiotic strategies deserve consideration in future well-powered trials. Future studies are needed to determine if preventive antibiotic and probiotic strategies are safe with regard to development of antibiotic resistance and probiotic infections. It should be determined whether the efficacy of probiotics improves when these agents are provided to the mouth and the intestines simultaneously. PMID:21232110
Airborne monitoring of crop canopy temperatures for irrigation scheduling and yield prediction
NASA Technical Reports Server (NTRS)
Millard, J. P.; Jackson, R. D.; Goettelman, R. C.; Reginato, R. J.; Idso, S. B.; Lapado, R. L.
1977-01-01
Airborne and ground measurements were made on April 1 and 29, 1976, over a USDA test site consisting mostly of wheat in various stages of water stress, but also including alfalfa and bare soil. These measurements were made to evaluate the feasibility of measuring crop temperatures from aircraft so that a parameter termed stress degree day, SDD, could be computed. Ground studies have shown that SDD is a valuable indicator of a crop's water needs, and that it can be related to irrigation scheduling and yield. The aircraft measurement program required predawn and afternoon flights coincident with minimum and maximum crop temperatures. Airborne measurements were made with an infrared line scanner and with color IR photography. The scanner data were registered, subtracted, and color-coded to yield pseudo-colored temperature-difference images. Pseudo-colored images reading directly in daily SDD increments were also produced. These maps enable a user to assess plant water status and thus determine irrigation needs and crop yield potentials.
de Smet, Anne Marie G A; Hopmans, Titia E M; Minderhoud, Albertus L C; Blok, Hetty E M; Gossink-Franssen, Annelies; Bernards, Alexandra T; Bonten, Marc J M
2009-09-01
To determine the incidence rates of hospital acquired infections (HAI) during the first 14 days after ICU discharge after treatment during ICU-stay with Selective Decontamination of the Digestive tract (SDD), Selective Oropharyngeal Decontamination (SOD) or Standard Care (SC). Prospective observational study. ICUs in two tertiary care hospitals. Patients discharged from the ICU to the ward. None. Post-ICU incidences of HAI per 1,000 days at risk were 11.2, 12.9 and 8.3 for patients that had received SDD (n = 296), SOD (n = 286) or SC (n = 289) respectively in ICU, yielding relative risks, as compared to SC, of 1.49 (CI(95) 0.9-2.47) for SOD and 1.44 (CI(95) 0.87-2.39) for SDD. Incidences of surgical site infections (per 100 surgical procedures) were 4 after SC and 11.8 and 8 after SOD and SDD (p = 0.04). Among patients that succumbed in the hospital after ICU-stay (n = 58) eight (14%) had developed HAI after ICU discharge; 3 of 21 after SDD, 3 of 15 after SOD and 2 of 22 after SC. Incidences of HAI in general wards tended to be higher in patients that had received either SDD or SOD during ICU-stay, but it seems unlikely that these infections have an effect on hospital mortality rates.
First neutron spectroscopy measurements with a pixelated diamond detector at JET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muraro, A., E-mail: muraro@ifp.cnr.it; Giacomelli, L.; Grosso, G.
2016-11-15
A prototype Single crystal Diamond Detector (SDD) was installed at the Joint European Torus (JET) in 2013 along an oblique line of sight and demonstrated the possibility to carry out neutron spectroscopy measurements with good energy resolution and detector stability in discharges heated by neutral beam injection and radio-frequency waves. Starting from these positive results, within the Vertical Neutron Spectrometer project of the Joint European Torus, we have developed a pixelated instrument consisting of a matrix of 12 independent SDDs, called the Diamond Vertical Neutron Spectrometer (DVNS), which boosts the detection efficiency of a single SDD by an order ofmore » magnitude. In this paper we describe the main features of the DVNS, including the detector design, energy resolution, and data acquisition system for on-line processing. Preliminary spectroscopy measurements of 2.5 MeV neutrons from the present deuterium plasma at JET are finally presented.« less
First neutron spectroscopy measurements with a pixelated diamond detector at JET.
Muraro, A; Giacomelli, L; Nocente, M; Rebai, M; Rigamonti, D; Belli, F; Calvani, P; Figueiredo, J; Girolami, M; Gorini, G; Grosso, G; Murari, A; Popovichev, S; Trucchi, D M; Tardocchi, M
2016-11-01
A prototype Single crystal Diamond Detector (SDD) was installed at the Joint European Torus (JET) in 2013 along an oblique line of sight and demonstrated the possibility to carry out neutron spectroscopy measurements with good energy resolution and detector stability in discharges heated by neutral beam injection and radio-frequency waves. Starting from these positive results, within the Vertical Neutron Spectrometer project of the Joint European Torus, we have developed a pixelated instrument consisting of a matrix of 12 independent SDDs, called the Diamond Vertical Neutron Spectrometer (DVNS), which boosts the detection efficiency of a single SDD by an order of magnitude. In this paper we describe the main features of the DVNS, including the detector design, energy resolution, and data acquisition system for on-line processing. Preliminary spectroscopy measurements of 2.5 MeV neutrons from the present deuterium plasma at JET are finally presented.
Infection control in intensive care units and prevention of ventilator-associated pneumonia.
Bonten, M J; Weinstein, R A
2000-12-01
Ventilator-associated pneumonia (VAP) is considered the most frequent infection in the intensive care unit (ICU), although incidence rates depend on the diagnostic methods. Because VAP has been associated with increased mortality and greater costs for medical care, prevention remains an important goal for intensive care medicine. Selective digestive decontamination (SDD), the most frequently studied method of infection prevention, is still controversial despite more than 30 prospective randomized trials and 6 metaanalyses. SDD reduces the incidence of VAP diagnoses, but beneficial effects on duration of ventilation or ICU stay, antibiotic use, and patient survival have not been shown unequivocally. Although recent metaanalyses suggest a 20% to 40% decrease in ICU mortality for SDD used with systemic prophylaxis, this benefit should be confirmed in a large, prospective, randomized study, preferably with a cost-benefit analysis. Selection of pathogens resistant to the antibiotics used in SDD remains the most important drawback of SDD, rendering SDD contraindicated in wards with endemic resistant problems. Other methods of infection prevention that do not create a selective growth advantage for resistant microorganisms may be more useful. Among these are the use of endotracheal tubes with the possibility of continuous aspiration of subglottic secretions, oropharyngeal decontamination with antiseptics, or the semirecumbent treatment position of patients. Although these methods were successful in single studies, more data are needed. Notwithstanding the potential benefits of these interventions, such classic infection control measures as handwashing remain the cornerstone of infection prevention.
NASA Astrophysics Data System (ADS)
Wuhrer, R.; Moran, K.
2018-01-01
The wavelength-dispersive X-ray spectrometer (WDS) has been around for a long time and the design has not changed much since its original development. The electron microprobe operator using WDS has to be meticulous in monitoring items such as gas flow, gas purity, gas pressure, noise levels of baseline and window, gas flow proportional counter (GFPC) voltage levels, count rate suppression, anode wire contamination and other detector parameters. Recent development and improvements of silicon drift detectors (SDD’s) has allowed the incorporation of a SDD as the X-ray detector in place of the proportional counter (PC) and/or gas flow proportional counter (GFPC). This allows minimal mechanical alteration and no loss of movement range. The superiority of a WDS with a SDD, referred to as SD-WDS, is easily seen once in operation. The SD-WDS removes many artefacts including the worse of all high order diffraction, thus allowing more accurate analysis. The incorporation of the SDD has been found to improve the light and mid element range and consequently improving the detection limit for these elements. It is also possible to obtain much more reliable results at high count rates with almost no change in resolution, gain and zero-peak characteristics of the energy spectrum.
2013-01-01
Introduction Selective decontamination of the digestive tract (SDD) is a prophylactic antibiotic regimen that is not widely used in practice. We aimed to describe the opinions of key ‘stakeholders’ about the validity of the existing evidence base, likely consequences of implementation, relative importance of their opinions in influencing overall practice, likely barriers to implementation and perceptions of the requirement for further research to inform the decision about whether to embark on a further large randomised controlled trial. Methods This was a Delphi study informed by comprehensive framework of possible determinants of health professionals’ behaviour to study Critical Care practice in four countries. There were four key stakeholder participant groups including ICU physicians, pharmacists, clinical leads, and clinical microbiologists/ infectious disease physicians. Round one comprised participant interviews and Rounds two and three were online questionnaires using Delphi method. Results In this study, 141 participants were recruited of whom 82% were retained. Participants rated themselves as knowledgeable about SDD. Antibiotic resistance was identified as the most important issue. SDD was seen as a low clinical priority but few participants reported strong opposition. There was moderate agreement that research to date has not adequately addressed concerns about antibiotic resistance and lacks generalizability. Participants indicated equipoise with regard to benefits and harms of SDD, and indicated strong support for a further randomised trial. Conclusions Clinicians have clinical equipoise about the effectiveness of SDD. Future research requires longer follow up to assess antibiotic resistance as well as greater validity/generalizability to provide definitive answers on the effectiveness of decontamination and effects on antibiotic resistance. SDD was regarded as not being a high clinical priority, which may limit future trial participation. These results have identified that further large randomised controlled trial of SDD in critical care is both warranted and appropriate. PMID:24207137
NASA Technical Reports Server (NTRS)
Wilber, George F.
2017-01-01
This Software Description Document (SDD) captures the design for developing the Flight Interval Management (FIM) system Configurable Graphics Display (CGD) software. Specifically this SDD describes aspects of the Boeing CGD software and the surrounding context and interfaces. It does not describe the Honeywell components of the CGD system. The SDD provides the system overview, architectural design, and detailed design with all the necessary information to implement the Boeing components of the CGD software and integrate them into the CGD subsystem within the larger FIM system. Overall system and CGD system-level requirements are derived from the CGD SRS (in turn derived from the Boeing System Requirements Design Document (SRDD)). Display and look-and-feel requirements are derived from Human Machine Interface (HMI) design documents and working group recommendations. This Boeing CGD SDD is required to support the upcoming Critical Design Review (CDR).
Krueger, W A; Heininger, A; Unertl, K E
2003-02-01
Selective digestive tract decontamination (SDD) is a method where topical non-absorbable antibiotics are applied to the oropharynx and stomach which primarily is aimed at the prevention of ventilator-associated pneumonia. The rationale for SDD is that ventilator associated pneumonia usually originates from the patients'own oropharyngeal microflora. SDD is also used for the prevention of gut-derived infections in acute necrotizing pancreatitis and in liver transplantation. Despite numerous clinical trials and several meta-analyses, SDD is still a controversial topic. It is now commonly accepted that the incidence of pneumonia is reduced,however, the concept of using topical antibiotics has its inherent limitations and the best results have been obtained by combination with a short course of intravenous antibiotics. Several issues surrounding the notorious difficulties in establishing the diagnosis of ventilator-associated pneumonia especially in the presence of antibiotics are an on-going matter of debate.Furthermore, pneumonia is the leading cause of death from nosocomial infections and its prevention was not adequately followed by reduced mortality in most individual trials, however, a benefit was suggested by recalculation of data in meta-analyses. Patients are not well defined by their need for ICU admission and mechanical ventilation and the attributable mortality of infections depends more on the type and severity of the underlying diseases. Recently published trials substantially improved our understanding as to which patients may derive most benefit from SDD.Currently, it seems that an improved survival can be achieved in surgical and trauma patients with severe but salvageable diseases, which might be classified e.g.by calculation of APACHE-II scores on admission.However, the most important drawback of SDD is the development of resistance and an increased selection pressure towards Gram-positive pathogens, especially in institutions with endemic multi-resistant microorganisms.Thus, it appears that "selective" must not only be interpreted as selective suppression of pathogenic bacteria but rather as selection of appropriate groups of patients with respect to underlying diseases and severity of illness. Furthermore, it means selection of ICUs where the endemic resistance patterns might allow the use of SDD at a relatively low risk for selection of resistant microorganisms, which is still the major concern associated with SDD.
2011-01-01
Introduction Selective digestive decontamination (SDD) appears to have a more compelling evidence base than non-antimicrobial methods for the prevention of ventilator associated pneumonia (VAP). However, the striking variability in ventilator associated pneumonia-incidence proportion (VAP-IP) among the SDD studies remains unexplained and a postulated contextual effect remains untested for. Methods Nine reviews were used to source 45 observational (benchmark) groups and 137 component (control and intervention) groups of studies of SDD and studies of three non-antimicrobial methods of VAP prevention. The logit VAP-IP data were summarized by meta-analysis using random effects methods and the associated heterogeneity (tau2) was measured. As group level predictors of logit VAP-IP, the mode of VAP diagnosis, proportion of trauma admissions, the proportion receiving prolonged ventilation and the intervention method under study were examined in meta-regression models containing the benchmark groups together with either the control (models 1 to 3) or intervention (models 4 to 6) groups of the prevention studies. Results The VAP-IP benchmark derived here is 22.1% (95% confidence interval; 95% CI; 19.2 to 25.5; tau2 0.34) whereas the mean VAP-IP of control groups from studies of SDD and of non-antimicrobial methods, is 35.7 (29.7 to 41.8; tau2 0.63) versus 20.4 (17.2 to 24.0; tau2 0.41), respectively (P < 0.001). The disparity between the benchmark groups and the control groups of the SDD studies, which was most apparent for the highest quality studies, could not be explained in the meta-regression models after adjusting for various group level factors. The mean VAP-IP (95% CI) of intervention groups is 16.0 (12.6 to 20.3; tau2 0.59) and 17.1 (14.2 to 20.3; tau2 0.35) for SDD studies versus studies of non-antimicrobial methods, respectively. Conclusions The VAP-IP among the intervention groups within the SDD evidence base is less variable and more similar to the benchmark than among the control groups. These paradoxical observations cannot readily be explained. The interpretation of the SDD evidence base cannot proceed without further consideration of this contextual effect. PMID:21214897
2009-01-01
Background The impact of dizziness on quality of life is often assessed by the Dizziness Handicap Inventory (DHI), which is used as a discriminate and evaluative measure. The aim of the present study was to examine reliability and validity of a translated Norwegian version (DHI-N), also examining responsiveness to important change in the construct being measured. Methods Two samples (n = 92 and n = 27) included participants with dizziness of mainly vestibular origin. A cross-sectional design was used to examine the factor structure (exploratory factor analysis), internal consistency (Cronbach's α), concurrent validity (Pearson's product moment correlation r), and discriminate ability (ROC curve analysis). Longitudinal designs were used to examine test-retest reliability (intraclass correlation coefficient (ICC) statistics, smallest detectable difference (SDD)), and responsiveness (Pearson's product moment correlation, ROC curve analysis; area under the ROC curve (AUC), and minimally important change (MIC)). The DHI scores range from 0 to 100. Results Factor analysis revealed a different factor structure than the original DHI, resulting in dismissal of subscale scores in the DHI-N. Acceptable internal consistency was found for the total scale (α = 0.95). Concurrent correlations between the DHI-N and other related measures were moderate to high, highest with Vertigo Symptom Scale-short form-Norwegian version (r = 0.69), and lowest with preferred gait (r = - 0.36). The DHI-N demonstrated excellent ability to discriminate between participants with and without 'disability', AUC being 0.89 and best cut-off point = 29 points. Satisfactory test-retest reliability was demonstrated, and the change for an individual should be ≥ 20 DHI-N points to exceed measurement error (SDD). Correlations between change scores of DHI-N and other self-report measures of functional health and symptoms were high (r = 0.50 - 0.57). Responsiveness of the DHI-N was excellent, AUC = 0.83, discriminating between self-perceived 'improved' versus 'unchanged' participants. The MIC was identified as 11 DHI-N points. Conclusions The DHI-N total scale demonstrated satisfactory measurement properties. This is the first study that has addressed and demonstrated responsiveness to important change of the DHI, and provided values of SDD and MIC to help interpret change scores. PMID:20025754
[Selective digestive decontamination. Why don't we apply the evidence in the clinical practice?].
Taylor, N; van Saene, H K F; Abella, A; Silvestri, L; Vucic, M; Peric, M
2007-04-01
Selective digestive decontamination (SDD) is a prophylactic strategy whose objective is to reduce the incidence of infections, mainly mechanical ventilation associated pneumonia in patients who require intensive cares, preventing or eradicating the oropharyngeal and gastrointestinal carrier state of potentially pathogenic microorganisms. Fifty-four randomized clinical trials (RCTs) and 9 meta-analysis have evaluated SDD. Thirty eight RCTs show a significant reduction of the infections and 4 of mortality. All the meta-analyses show a significant reduction of the infections and 5 out of the 9 meta-analyses report a significant reduction in mortality. Thus, 5 patients from the ICU with SDD must be treated to prevent pneumonia and 12 patients from the ICU should be treated to prevent one death. The data that show benefit of the SDD on mortality have an evidence grade 1 or recommendation grade A (supported by at least two level 1 investigations). The aim of this review is to explain the pathogeny of infections in critical patients, describe selective digestive decontamination, analyze the evidence available on it efficacy and the potential adverse effects and discuss the reasons published by the experts who advise against the use of SDD, even though it is recognized as the best intervention evaluated in intensive cares to reduce morbidity and mortality of the infections.
Feasibility of same day discharge after robotic assisted pelvic floor reconstruction.
Lloyd, Jessica C; Guzman-Negron, Juan; Goldman, Howard B
2018-06-01
Robotic surgical procedures have become more common in female pelvic reconstruction. Purported benefits of robotic assisted pelvic floor reconstruction (RAPFR) procedures include shorter hospital stay, faster recovery, lower blood loss, and decreased postoperative pain. Following RAPFR procedures, the current accepted practice is discharge after a one-night hospitalization. We assessed whether same day discharge (SDD) affects the short term safety of and patient satisfaction with robotic assisted pelvic floor reconstructive procedures, relative to those who remain hospitalized overnight. We retrospectively reviewed the charts of women who underwent RAPFR procedures between October 2015 and October 2016. A same day discharge protocol for RAPFR was initiated in July 2016. To date, 10 patients have undergone SDD. These patients were compared to the consecutive patients from the prior 9 months who stayed overnight. To evaluate short term safety, we reviewed the medical record for any unscheduled Cleveland Clinic emergency department (ED) and/or office visits within 30 days of the RAPFR procedure. We then sent a mailed survey to all patients, querying their pelvic organ prolapse-related PGI-I and also offering a postoperative satisfaction questionnaire. Demographic, perioperative, postoperative data and survey results were compared using Student's t test and Fisher's exact test. In our series, 38 patients (95%) underwent robotic assisted sacrocolpopexy (RASC). Only 2 (5%) had a different RAPFR procedure, a robotic assisted vaginal mesh excision. Concomitant robotic assisted supracervical hysterectomy (SCH) was performed in 9 patients (30%) in the overnight group, whereas 1 of the SDD patients underwent SCH (10%). Demographics and operative characteristics did not differ between groups. Ultimately, patients in the SDD group were no more likely than the overnight group to require an unscheduled ED or office visit in the early postoperative period. With respect to satisfaction, no significant differences were observed between groups, with both groups noting substantial improvement in POP symptoms following surgery. In this pilot study, same day discharge after RAPFR procedures appears to be safe and feasible. RAPFR procedures were well-tolerated, with no difference in ED or non-urology office visits occurring during the early post-operative period in our series, regardless of length of stay. Patient satisfaction was equivalent between groups and universally high.
Li, Jun; Zhu, Liang; Xu, Ming; Han, Juntao; Bai, Xiaozhi; Yang, Xuekang; Zhu, Huayu; Xu, Jie; Zhang, Xing; Gong, Yangfan; Hu, Dahai; Gao, Feng
2015-08-01
Severe burns often initiate the prevalence of hyperglycemia and insulin resistance, significantly contributing to adverse clinical outcomes. However, there are limited treatment options. This study was designed to investigate the role and the underlying mechanisms of oral antibiotics to selectively decontaminate the digestive tract (SDD) on burn-induced insulin resistance. Rats were subjected to 40% of total body surface area full-thickness burn or sham operation with or without SDD treatment. Translocation of FITC-labeled LPS was measured at 4h after burn. Furthermore, the effect of SDD on post-burn quantity of gram-negative bacteria in gut was investigated. Serum or muscle LPS and proinflammatory cytokines were measured. Intraperitoneal glucose tolerance test and insulin tolerance test were used to determine the status of systemic insulin resistance. Furthermore, intracellular insulin signaling (IRS-1 and Akt) and proinflammatory related kinases (JNK and IKKβ) were assessed by western blot. Burn increased the translocation of LPS from gut 4h after injury. SDD treatment effectively inhibited post-burn overgrowth of gram-negative enteric bacilli in gut. In addition, severe burns caused significant increases in the LPS and proinflammatory cytokines levels, activation of proinflammatory related kinases, and systemic insulin resistance as well. But SDD treatment could significantly attenuate burn-induced insulin resistance and improve the whole-body responsiveness to insulin, which was associated with the inhibition of gut-derived LPS, cytokines, proinflammatory related kinases JNK and IKKβ, as well as activation of IRS-1 and Akt. SDD appeared to have an effect on proinflammatory signaling cascades and further reduced severe burn-induced insulin resistance. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Kopec, Anna K; Kim, Suntae; Forgacs, Agnes L; Zacharewski, Timothy R; Proctor, Deborah M; Harris, Mark A; Haws, Laurie C; Thompson, Chad M
2012-02-15
Chronic administration of high doses of hexavalent chromium [Cr(VI)] as sodium dichromate dihydrate (SDD) elicits alimentary cancers in mice. To further elucidate key events underlying tumor formation, a 90-day drinking water study was conducted in B6C3F1 mice. Differential gene expression was examined in duodenal and jejunal epithelial samples following 7 or 90days of exposure to 0, 0.3, 4, 14, 60, 170 or 520mg/L SDD in drinking water. Genome-wide microarray analyses identified 6562 duodenal and 4448 jejunal unique differentially expressed genes at day 8, and 4630 and 4845 unique changes, respectively, in the duodenum and jejunum at day 91. Comparative analysis identified significant overlap in duodenal and jejunal differential gene expression. Automated dose-response modeling identified >80% of the differentially expressed genes exhibited sigmoidal dose-response curves with EC(50) values ranging from 10 to 100mg/L SDD. Only 16 genes satisfying the dose-dependent differential expression criteria had EC(50) values <10mg/L SDD, 3 of which were regulated by Nrf2, suggesting oxidative stress in response to SDD at low concentrations. Analyses of differentially expressed genes identified over-represented functions associated with oxidative stress, cell cycle, lipid metabolism, and immune responses consistent with the reported effects on redox status and histopathology at corresponding SDD drinking water concentrations. Collectively, these data are consistent with a mode of action involving oxidative stress and cytotoxicity as early key events. This suggests that the tumorigenic effects of chronic Cr(VI) oral exposure likely require chronic tissue damage and compensatory epithelial cell proliferation. Copyright © 2011 Elsevier Inc. All rights reserved.
ICU-acquired candidemia within selective digestive decontamination studies: a meta-analysis.
Hurley, James C
2015-11-01
To estimate the direct and indirect (contextual) effects of the factorized constituents of selective digestive decontamination and selective oropharyngeal decontamination (SDD/SOD), being topical antibiotic (TA) and protocolized antifungal prophylaxis (PAFP), on ICU-acquired candidemia. A broad range of ICU candidemia incidence studies were sourced to serve as points of reference. The candidemia incidence was extracted from component (control and intervention) groups decanted from studies of various designs (concurrent or non-concurrent) and whether investigating SDD/SOD versus non-TA methods of ICU infection prevention. The candidemia incidences were summarized in regression models using generalized estimating equation (GEE) methods. Groups derived from observational studies (no prevention method under study) provided an overarching external benchmark candidemia incidence for calibration. Within studies investigating SDD/SOD, the mean (and 95% confidence interval) candidemia incidence among concurrent component groups (40 control; 2.4%; 1.7-3.2% and 43 intervention groups; 2.4%; 1.6-3.1%), but not non-concurrent control groups (11 groups; 1.6%; 0.1-2.7%), is higher than that of the benchmark candidemia incidence derived from 54 observational groups (1.5%; 1.2-1.9%). The TA constituent within SDD/SOD has significant direct and indirect (contextual) effects in GEE models even after adjusting for the publication year and the group-wide presence of either candidemia risk factors or PAFP use. The TA constituent of SDD/SOD is associated with a contextual effect on candidemia incidence which is similar in magnitude to that of the conventional candidemia risk factors and against which PAFP partially attenuates. This increase is inapparent within individual SDD/SOD studies examined in isolation.
Cymerman, Rachel M; Skolnick, Adam H; Cole, William J; Nabati, Camellia; Curcio, Christine A; Smith, R Theodore
2016-11-01
Reticular macular disease (RMD) is the highest risk form of early age-related macular degeneration and also specifically confers decreased longevity. However, because RMD requires advanced retinal imaging for adequate detection of its characteristic subretinal drusenoid deposits (SDD), it has not yet been completely studied with respect to coronary artery disease (CAD), the leading cause of death in the developed world. Because CAD appears in middle age, our purpose was to screen patients aged 45-80 years, documented either with or without CAD, to determine if CAD is associated with RMD. A prospective cohort study of patients with documented CAD status and no known retinal disease in a clinical practice setting at one institution. Subjects and Controls: A number of 76 eyes from 38 consecutive patients (23 with documented CAD, 15 controls documented without CAD; 47.4% female; mean age 66.7 years). Patients were imaged with near-infrared reflectance/spectral domain optical coherence tomography and assessed in masked fashion by two graders for the presence of SDD lesions of RMD and soft drusen. Presence or absence of RMD/SDD and soft drusen. RMD was more frequent in patients with CAD versus those without (Relative Risk [RR] = 2.1, CI = 1.08-3.95, P = 0.03). There was no association of CAD with soft drusen. A specific relationship between CAD and RMD suggests common systemic causes for both and warrants further study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopec, Anna K.; Kim, Suntae; Forgacs, Agnes L.
2012-02-15
Chronic administration of high doses of hexavalent chromium [Cr(VI)] as sodium dichromate dihydrate (SDD) elicits alimentary cancers in mice. To further elucidate key events underlying tumor formation, a 90-day drinking water study was conducted in B6C3F1 mice. Differential gene expression was examined in duodenal and jejunal epithelial samples following 7 or 90 days of exposure to 0, 0.3, 4, 14, 60, 170 or 520 mg/L SDD in drinking water. Genome-wide microarray analyses identified 6562 duodenal and 4448 jejunal unique differentially expressed genes at day 8, and 4630 and 4845 unique changes, respectively, in the duodenum and jejunum at day 91.more » Comparative analysis identified significant overlap in duodenal and jejunal differential gene expression. Automated dose–response modeling identified > 80% of the differentially expressed genes exhibited sigmoidal dose–response curves with EC{sub 50} values ranging from 10 to 100 mg/L SDD. Only 16 genes satisfying the dose-dependent differential expression criteria had EC{sub 50} values < 10 mg/L SDD, 3 of which were regulated by Nrf2, suggesting oxidative stress in response to SDD at low concentrations. Analyses of differentially expressed genes identified over-represented functions associated with oxidative stress, cell cycle, lipid metabolism, and immune responses consistent with the reported effects on redox status and histopathology at corresponding SDD drinking water concentrations. Collectively, these data are consistent with a mode of action involving oxidative stress and cytotoxicity as early key events. This suggests that the tumorigenic effects of chronic Cr(VI) oral exposure likely require chronic tissue damage and compensatory epithelial cell proliferation. Highlights: ► Mouse small intestine gene expression is highly responsive to hexavalent chromium [Cr(VI)]. ► Cr(VI) elicits more differential gene expression after 7 days of exposure than 90 days of exposure. ► Oral exposure to Cr(VI) leads to oxidative stress, cell cycle, lipid and immune dysregulation. ► Cr(VI) elicits dose-dependent changes in gene expression with an overall median EC{sub 50} of 47 mg/L SDD.« less
High level tritiated water monitoring by Bremsstrahlung counting using a silicon drift detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niemes, S.; Sturm, M.; Michling, R.
2015-03-15
The β-ray induced X-ray spectrometry (BIXS) is a promising technique to monitor the tritium concentration in a fuel cycle of a fusion reactor. For in-situ measurements of high level tritiated water by Bremsstrahlung counting, the characteristics of a low-noise silicon drift detector (SDD) have been examined at the Tritium Laboratory Karlsruhe (TLK). In static measurements with constant sample volume and tritium concentration, the Bremsstrahlung spectra of tritiated water samples in a concentration range of 0.02 to 15 MBq/ml have been obtained. The volume has been kept constant at 5 cm{sup 3}. The observed spectra are well above the noise threshold.more » In addition to X-rays induced by β-rays, the spectra feature X-ray fluorescence peaks of the surrounding materials. No indications of memory effects have been observed. A linear relation between the X-ray intensity and the tritium concentration was obtained and the lower detection limit of the setup has been determined to 1 MBq ml{sup -1}, assessed by the Curie criterion. In addition, the spectra obtained experimentally could be reproduced with high agreement by Monte-Carlo simulations using the GEANT4-tool-kit. It was found that the present detection system is applicable to non-invasive measurements of high-level tritiated water and the SDD is a convenient tool to detect the low energy Bremsstrahlung X-rays. (authors)« less
NASA Astrophysics Data System (ADS)
Coogan, J. C.; Decelles, P. G.
2007-12-01
Palinspastic reconstruction of Mesozoic thrust sheets provides the main constraint for an estimated 47 km of Cenozoic extensional displacement along the Sevier Desert detachment (SDD) in the central Sevier Desert Basin. Hanging wall and footwall piercing points indicate that the SDD accommodated a minimum of 35 km of extensional displacement in the narrower southern part of the basin. The piercing points for the SDD are defined by the intersection of the SDD, the Canyon Range thrust (CRT), and a regional early Cenozoic erosion surface (ES). The hanging wall piercing point lies immediately northeast of the Cricket Mountains, where the SDD-CRT- ES intersection is narrowly defined by intersecting structure maps derived from published seismic reflection data. The footwall piercing point lies in the southern foothills of the Canyon Range, where the SDD breakaway plane is well constrained by an industry seismic line that lies within 2 km of the exposed intersection of the CRT with the base of the Oligocene Oak City Formation. Timing of extension in the southern Sevier Desert basin is constrained by a kinematic reconstruction of detachment and imbricate fault displacement, footwall uplift, and supradetachment sedimentation for Oligocene, Miocene, and Plio-Pleistocene seismic sequences. The reconstruction is centered on a seismic reflection and gravity interpretation along the published Pan Canadian profiles 2 and 3 that is tied to dated intervals in six industry wells. Fault restoration indicates that Oligocene and Miocene phases of slip each accounted for about 40 percent of the total displacement. Simultaneous backstripping of the Oligocene, Miocene, and Plio-Pleistocene supradetachment sequences records hanging wall subsidence simultaneous with footwall uplift, with a footwall burial history that is consistent with published Miocene apatite and zircon fission-track ages of footwall samples. The geometric evolution of the southern SDD extensional system is consistent with its development above a broad westward-migrating "rolling hinge" zone associated with isostatic uplift of the detachment footwall. Hanging wall normal faults east of the footwall crest exhibit small post-Miocene displacement, with demonstrable Quaternary slip restricted to the crest and western limb of the uplift, most notably along the Black Rock and Clear Lake fault zones. Early abandonment of the eastern part of the detachment may explain the indistinct geomorphic and structural expression of the break-away zone at the surface. The deepest level of the southern SDD also presents a complex geometry and kinematic history. The 1996 Chevron 1-29 Black Rock Federal well through the western basin margin penetrated a normal fault that places Jurassic over lower Cambrian strata at 4650 m measured depth, well above the principal SDD seismic reflection. The fault is not correlated to any large- displacement high-angle fault at shallow levels, and may form the abandoned roof to an extensional duplex.
Richter, Sandra S.; Galask, Rudolph P.; Messer, Shawn A.; Hollis, Richard J.; Diekema, Daniel J.; Pfaller, Michael A.
2005-01-01
There are limited data regarding the antifungal susceptibility of yeast causing vulvovaginal candidiasis, since cultures are rarely performed. Susceptibility testing was performed on vaginal yeast isolates collected from January 1998 to March 2001 from 429 patients with suspected vulvovaginal candidiasis. The charts of 84 patients with multiple positive cultures were reviewed. The 593 yeast isolates were Candida albicans (n = 420), Candida glabrata (n = 112), Candida parapsilosis (n = 30), Candida krusei (n = 12), Saccharomyces cerevisiae ( n = 9), Candida tropicalis (n = 8), Candida lusitaniae (n = 1), and Trichosporon sp. (n = 1). Multiple species suggesting mixed infection were isolated from 27 cultures. Resistance to fluconazole and flucytosine was observed infrequently (3.7% and 3.0%); 16.2% of isolates were resistant to itraconazole (MIC ≥ 1 μg/ml). The four imidazoles (econazole, clotrimazole, miconazole, and ketoconazole) were active: 94.3 to 98.5% were susceptible at ≤1 μg/ml. Among different species, elevated fluconazole MICs (≥16 μg/ml) were only observed in C. glabrata (15.2% resistant [R], 51.8% susceptible-dose dependent [S-DD]), C. parapsilosis (3.3% S-DD), S. cerevisiae (11.1% S-DD), and C. krusei (50% S-DD, 41.7% R, considered intrinsically fluconazole resistant). Resistance to itraconazole was observed among C. glabrata (74.1%), C. krusei (58.3%), S. cerevisiae (55.6%), and C. parapsilosis (3.4%). Among 84 patients with recurrent episodes, non-albicans species were more common (42% versus 20%). A ≥4-fold rise in fluconazole MIC was observed in only one patient with C. parapsilosis. These results support the use of azoles for empirical therapy of uncomplicated candidal vulvovaginitis. Recurrent episodes are more often caused by non-albicans species, for which azole agents are less likely to be effective. PMID:15872235
Katchman, E; Marquez, M; Bazerbachi, F; Grant, D; Cattral, M; Low, C Y; Renner, E; Humar, A; Selzner, M; Ghanekar, A; Rotstein, C; Husain, S
2014-08-01
Bacterial infections are major causes of early morbidity and mortality after liver transplantation. Selective digestive decontamination (SDD) can be used pre-operatively for living-donor liver transplant (LD-LT), but its role in this setting remains controversial. To evaluate this strategy, we retrospectively analyzed a cohort of consecutive LD-LTs performed in our center from March 2007 to February 2011 and compared the incidence and nature of early infectious complications, length of intensive care unit stay and hospitalization, antibiotic use, and emergence of resistant bacteria in patients with or without SDD prophylaxis. Of 148 LD-LTs in the study period, 111 received SDD prophylaxis while 37 did not. In a multivariate model, the independent factors associated with an increased risk of early post-transplant infections were length of postoperative mechanical ventilation (for every additional day odds ratio [OR] = 2.37, 95% confidence interval [CI] 1.4-4.0; P = 0.002), and choledochojejunostomy (OR = 4.5, 95% CI 1.95-10.5; P < 0.001). Use of SDD did not affect the rate or distribution of infectious complications, duration of hospitalization, antibiotic use, or acquisition of resistant bacteria (OR = 3.52, 95% CI 0.43-15.17; P = 0.376). In conclusion, the use of SDD prophylaxis in LD-LT was not beneficial and should be avoided, as it offers no advantage and could potentiate the emergence of multidrug-resistant organisms. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Lechner, P.; Eckhard, R.; Fiorini, C.; Gola, A.; Longoni, A.; Niculae, A.; Peloso, R.; Soltau, H.; Strüder, L.
2008-07-01
Silicon Drift Detectors (SDDs) are used as low-capacitance photon detectors for the optical light emitted by scintillators. The scintillator crystal is directly coupled to the SDD entrance window. The entrance window's transmittance can be optimized for the scintillator characteristic by deposition of a wavelength-selective anti-reflective coating. Compared to conventional photomultiplier tubes the SDD readout offers improved energy resolution and avoids the practical problems of incompatibility with magnetic fields, instrument volume and requirement of high voltage. A compact imaging spectrometer for hard X-rays and γ-rays has been developed by coupling a large area (29 × 26 mm2) monolithic SDD array with 77 hexagonal cells to a single non-structured CsI-scintillator of equal size. The scintillation light generated by the absorption of an energetic photon is seen by a number of detector cells and the position of the photon interaction is reconstructed by the centroid method. The measured spatial resolution of the system (<= 500 μm) is considerably smaller than the SDD cell size (3.2 mm) and in the order required at the focal plane of high energy missions. The energy information is obtained by summing the detector cell signals. Compared to direct converting pixelated detectors, e.g. CdTe with equal position resolution the scintillator-SDD combination requires a considerably lower number of readout channels. In addition it has the advantages of comprehensive material experience, existing technologies, proven long term stability, and practically unlimited availability of high quality material.
Characterization of Phase Separation Propensity for Amorphous Spray Dried Dispersions.
McNamara, Daniel; Yin, Shawn; Pan, Duohai; Crull, George; Timmins, Peter; Vig, Balvinder
2017-02-06
A generalized screening approach, applying isothermal calorimetry at 37 °C 100% RH, to formulations of spray dried dispersions (SDDs) for two active pharmaceutical ingredients (APIs) (BMS-903452 and BMS-986034) is demonstrated. APIs 452 and 034, with similar chemotypes, were synthesized and promoted during development for oral dosing. Both APIs were formulated as SDDs for animal exposure studies using the polymer hydroxypropylmethlycellulose acetyl succinate M grade (HPMCAS-M). 452 formulated at 30% (wt/wt %) was an extremely robust SDD that was able to withstand 40 °C 75% RH open storage conditions for 6 months with no physical evidence of crystallization or loss of dissolution performance. Though 034 was a chemical analogue with similar physical chemical properties to 452, a physically stable SDD of 034 could not be formulated in HPMCAS-M at any of the drug loads attempted. This study was used to develop experience with specific physical characterization laboratory techniques to evaluate the physical stability of SDDs and to characterize the propensity of SDDs to phase separate and possibly crystallize. The screening strategy adopted was to stress the formulated SDDs with a temperature humidity screen, within the calorimeter, and to apply orthogonal analytical techniques to gain a more informed understanding of why these SDDs formulated with HPMCAS-M demonstrated such different physical stability. Isothermal calorimetry (thermal activity monitor, TAM) was employed as a primary stress screen wherein the SDD formulations were monitored for 3 days at 37 °C 100% RH for signs of phase separation and possible crystallization of API. Powder X-ray diffraction (pXRD), modulated differential scanning calorimetry (mDSC), Fourier transform infrared spectroscopy (FTIR), and solid state nuclear magnetic resonance (ssNMR) were all used to examine formulated SDDs and neat amorphous drug. 452 SDDs formulated at 30% (wt/wt %) or less did not show phase separation behavior upon exposure to 37 °C 100% RH for 3 days. 034 SDD formulations from 10 through 50% (wt/wt %) all demonstrated thermal traces consistent with exothermic phase separation events over 3 days at 37 °C 100% RH in the TAM. However, only the 15, 30, and 50% containing 034 samples showed pXRD patterns consistent with crystalline material in post-TAM samples. Isothermal calorimetry is a useful screening tool to probe robust SDD physical performance and help investigate the level of drug polymer miscibility under a humid stress. Orthogonal analytical techniques such as pXRD, ssNMR, and FTIR were key in this SDD formulation screening to gain physical understanding and confirm or refute whether physical changes occur during the observed thermal events characterized by the calorimetric screening experiments.
Efficacy of subantimicrobial-dose doxycycline against nitrosative stress in chronic periodontitis.
Pârvu, Alina Elena; Alb, Sandu Florin; Crăciun, Alexandra; Taulescu, Marian Aurel
2013-02-01
To evaluate the effectiveness of subantimicrobial-dose doxycycline (SDD) as an adjunct to scaling and root planing (SRP) treatment against the nitrosative stress of moderate to advanced chronic periodontitis. Adults with untreated chronic periodontitis (n=174) were randomly administered SRP+SDD (n=87) (20 mg of doxycycline twice daily) or SRP+placebo (n=87) treatment for 3 months. At baseline and after 3 months, the probing depths (PD), bleeding on probing (BOP) and clinical attachment level (CAL) were measured, and a gingivomucosal biopsy was collected to assay the induction of nitric oxide synthase (iNOS) and 3-nitrotyrosine (3NT), and blood was collected to assay for total nitrites and nitrates (NO(x)) and 3NT. Compared to baseline, at the completion of treatment, significant decreases in the levels of tissue iNOS and 3NT and serum NO(x) and 3NT were observed in both groups. SRP+SDD yielded a greater reduction in the gingivomucosal and serum nitrosative stress markers than did SRP+placebo. PD, BOP, and CAL reduction were correlated with the nitrosative stress parameters. On a short-term basis, SDD therapy may be used as an adjunct to SRP treatment against nitrosative stress in moderate to advanced chronic periodontitis.
Kappen, Peter; Tröger, Larc; Materlik, Gerhard; Reckleben, Christian; Hansen, Karsten; Grunwaldt, Jan-Dierk; Clausen, Bjerne S
2002-07-01
A silicon drift detector (SDD) was used for ex situ and time-resolved in situ fluorescence X-ray absorption fine structure (XAFS) on low-concentrated catalyst samples. For a single-element and a seven-element SDD the energy resolution and the peak-to-background ratio were verified at high count rates, sufficient for fluorescence XAFS. An experimental set-up including the seven-element SDD without any cooling and an in situ cell with gas supply and on-line gas analysis was developed. With this set-up the reduction and oxidation of a zeolite supported catalyst containing 0.3 wt% platinum was followed by fluorescence near-edge scans with a time resolution of 10 min each. From ex situ experiments on low-concentrated platinum- and gold-based catalysts fluorescence XAFS scans could be obtained with sufficient statistical quality for a quantitative analysis. Structural information on the gold and platinum particles could be extracted by both the Fourier transforms and the near-edge region of the XAFS spectra. Moreover, it was found that with the seven-element SDD concentrations of the element of interest as low as 100 ppm can be examined by fluorescence XAFS.
Kyriacou, Andreas; Li Kam Wa, Matthew E; Pabari, Punam A; Unsworth, Beth; Baruah, Resham; Willson, Keith; Peters, Nicholas S; Kanagaratnam, Prapa; Hughes, Alun D; Mayet, Jamil; Whinnett, Zachary I; Francis, Darrel P
2013-08-10
In atrial fibrillation (AF), VV optimization of biventricular pacemakers can be examined in isolation. We used this approach to evaluate internal validity of three VV optimization methods by three criteria. Twenty patients (16 men, age 75 ± 7) in AF were optimized, at two paced heart rates, by LVOT VTI (flow), non-invasive arterial pressure, and ECG (minimizing QRS duration). Each optimization method was evaluated for: singularity (unique peak of function), reproducibility of optimum, and biological plausibility of the distribution of optima. The reproducibility (standard deviation of the difference, SDD) of the optimal VV delay was 10 ms for pressure, versus 8 ms (p=ns) for QRS and 34 ms (p<0.01) for flow. Singularity of optimum was 85% for pressure, 63% for ECG and 45% for flow (Chi(2)=10.9, p<0.005). The distribution of pressure optima was biologically plausible, with 80% LV pre-excited (p=0.007). The distributions of ECG (55% LV pre-excitation) and flow (45% LV pre-excitation) optima were no different to random (p=ns). The pressure-derived optimal VV delay is unaffected by the paced rate: SDD between slow and fast heart rate is 9 ms, no different from the reproducibility SDD at both heart rates. Using non-invasive arterial pressure, VV delay optimization by parabolic fitting is achievable with good precision, satisfying all 3 criteria of internal validity. VV optimum is unaffected by heart rate. Neither QRS minimization nor LVOT VTI satisfy all validity criteria, and therefore seem weaker candidate modalities for VV optimization. AF, unlinking interventricular from atrioventricular delay, uniquely exposes resynchronization concepts to experimental scrutiny. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Gillick, Bernadette T; Krach, Linda E; Feyma, Tim; Rich, Tonya L; Moberg, Kelli; Thomas, William; Cassidy, Jessica M; Menk, Jeremiah; Carey, James R
2014-01-01
The aim of this study was to determine the feasibility and efficacy of five treatments of 6 Hz primed, low-frequency, repetitive transcranial magnetic stimulation (rTMS) combined with constraint-induced movement therapy (CIMT) to promote recovery of the paretic hand in children with congenital hemiparesis. Nineteen children with congenital hemiparesis aged between 8 and 17 years (10 males, nine females; mean age 10 years 10 months, SD 2 years 10 months; Manual Ability Classification Scale levels I-III) underwent five sessions of either real rTMS (n=10) or sham rTMS (n=9) alternated daily with CIMT. CIMT consisted of 13 days of continuous long-arm casting with five skin-check sessions. Each child received a total of 10 hours of one-to-one therapy. The primary outcome measure was the Assisting Hand Assessment (AHA) and the secondary outcome variables were the Canadian Occupational Performance Measure (COPM) and stereognosis. A Wilcoxon signed-rank sum test was used to analyze differences between pre- and post-test scores within the groups. Analysis of covariance was used to compute mean differences between groups adjusting for baseline. Fisher's exact test was used to compare individual change in AHA raw scores with the smallest detectable difference (SDD) of 4 points. All participants receiving treatment finished the study. Improvement in AHA differed significantly between groups (p=0.007). No significant differences in the secondary outcome measures were found. Eight out of 10 participants in the rTMS/CIMT group showed improvement greater than the SDD, but only two out of nine in the sham rTMS/CIMT group showed such improvement (p=0.023). No serious adverse events occurred. Primed, low-frequency rTMS combined with CIMT appears to be safe, feasible, and efficacious in pediatric hemiparesis. Larger clinical trials are now indicated. © 2013 Mac Keith Press.
Cloud-based Computing and Applications of New Snow Metrics for Societal Benefit
NASA Astrophysics Data System (ADS)
Nolin, A. W.; Sproles, E. A.; Crumley, R. L.; Wilson, A.; Mar, E.; van de Kerk, M.; Prugh, L.
2017-12-01
Seasonal and interannual variability in snow cover affects socio-environmental systems including water resources, forest ecology, freshwater and terrestrial habitat, and winter recreation. We have developed two new seasonal snow metrics: snow cover frequency (SCF) and snow disappearance date (SDD). These metrics are calculated at 500-m resolution using NASA's Moderate Resolution Imaging Spectroradiometer (MODIS) snow cover data (MOD10A1). SCF is the number of times snow is observed in a pixel over the user-defined observation period. SDD is the last date of observed snow in a water year. These pixel-level metrics are calculated rapidly and globally in the Google Earth Engine cloud-based environment. SCF and SDD can be interactively visualized in a map-based interface, allowing users to explore spatial and temporal snowcover patterns from 2000-present. These metrics are especially valuable in regions where snow data are sparse or non-existent. We have used these metrics in several ongoing projects. When SCF was linked with a simple hydrologic model in the La Laguna watershed in northern Chile, it successfully predicted summer low flows with a Nash-Sutcliffe value of 0.86. SCF has also been used to help explain changes in Dall sheep populations in Alaska where sheep populations are negatively impacted by late snow cover and low snowline elevation during the spring lambing season. In forest management, SCF and SDD appear to be valuable predictors of post-wildfire vegetation growth. We see a positive relationship between winter SCF and subsequent summer greening for several years post-fire. For western US winter recreation, we are exploring trends in SDD and SCF for regions where snow sports are economically important. In a world with declining snowpacks and increasing uncertainty, these metrics extend across elevations and fill data gaps to provide valuable information for decision-making. SCF and SDD are being produced so that anyone with Internet access and a Google account can access, visualize, and download the data with a minimum of technical expertise and no need for proprietary software.
Expanding the detection efficiency of silicon drift detectors
NASA Astrophysics Data System (ADS)
Schlosser, D. M.; Lechner, P.; Lutz, G.; Niculae, A.; Soltau, H.; Strüder, L.; Eckhardt, R.; Hermenau, K.; Schaller, G.; Schopper, F.; Jaritschin, O.; Liebel, A.; Simsek, A.; Fiorini, C.; Longoni, A.
2010-12-01
To expand the detection efficiency Silicon Drift Detectors (SDDs) with various customized radiation entrance windows, optimized detector areas and geometries have been developed. Optimum values for energy resolution, peak to background ratio (P/B) and high count rate capability support the development. Detailed results on sensors optimized for light element detection down to Boron or even lower will be reported. New developments for detecting medium and high X-ray energies by increasing the effective detector thickness will be presented. Gamma-ray detectors consisting of a SDD coupled to scintillators like CsI(Tl) and LaBr 3(Ce) have been examined. Results of the energy resolution for the 137Cs 662 keV line and the light yield (LY) of such detector systems will be reported.
Masiran, Ruziana; Sidi, Hatta; Mohamed, Zahurin; Mohamed Saini, Suriati; Nik Jaafar, Nik Ruzyanei
2013-04-01
SSRIs are known for their sexual side-effects with a variable rate of sexual dysfunction (SD). 5HT2A (rs6311) single nucleotide polymorphism (SNP) was found to have significant association with SD. The purpose of this study was to determine the prevalence of female SDD, its clinical correlates and association with 5HT2A (rs6311) SNP in patients with major depressive disorder (MDD) treated with SSRIs. This was a cross-sectional study. We evaluated 95 female outpatients with MDD treated with SSRIs who were in remission. Outcome measures were stratified by the presence or absence of SDD. A buccal swab was obtained from each patient and sent for genotyping in the Pharmacogenomics and Medical Biotechnology Laboratory of Universiti Malaya. The overall prevalence of female SD was 32.6%. The prevalence of female SDD was 62.1%. Those with arousal problem, lubrication problem, sexual satisfaction problem, orgasm problem and problematic marriage were more likely to have sexual desire disorder. The majority of participants who had sexual desire disorder had genotype TT (42.4%) but there was no significant association observed. After controlling for age, number of children, education level, SSRI type, lubrication problem, orgasm problem, satisfaction problem and marital problem, only arousal problem significantly enhanced the presence of sexual desire disorder by 8.5 times (odds ratio = 8.46, 95% confidence interval = 1.24-57.58; P = 0.018). This study showed that there was no significant association between SDD and the 5HT2A (rs6311) SNP. Arousal problem significantly enhanced the presence of sexual desire disorder. Copyright © 2013 Wiley Publishing Asia Pty Ltd.
Hong, Jeong-Ho; Jang, Min Uk; Choi, Nack Cheon; Lee, Ji Sung; Kim, Beom Joon; Han, Moon-Ku; Bae, Hee-Joon
2017-01-01
Background How short-term blood pressure variability (BPV) is affected in the acute stage of ischemic stroke and whether BPV is associated with early neurologic outcomes remains unclear. Methods Patients who admitted for ischemic stroke within 24 h of symptom onset were consecutively identified between January 2010 and January 2015. BP profiles measured in real-time were summarized into short-term, 24-h time intervals, based on standard deviation (SD) and mean of systolic BP (SBPSD) during the first 3 days. The primary outcome was daily assessment of early neurological deterioration (END). The associations between short-term SBPSD values and the secular trend for primary outcome were examined. Results A total of 2,545 subjects (mean age, 67.1 ± 13.5 years old and median baseline National Institutes of Health Stroke Scale score, 3) arrived at the hospital an average of 6.1 ± 6.6 h after symptom onset. SBPSD values at day 1 (SD#D1), SD#D2, and SD#D3 were 14.4 ± 5.0, 12.5 ± 4.5, and 12.2 ± 4.6 mmHg, respectively. Multivariable analyses showed that SD#D2 was independently associated with onset of END at day 2 (adjusted odds ratio, 1.08; 95% confidence interval, 1.03–1.13), and SD#D3 was independently associated with END#D3 (1.07, 1.01–1.14), with adjustments for predetermined covariates, SBPmean, and interactions with daily SBPSD. Conclusion Short-term BPV changed and stabilized from the first day of ischemic stroke. Daily high BPV may be associated with neurological deterioration independent of BPV on the previous day. PMID:29252991
Engebretson, Steven P.; Hey-Hadavi, Judith
2011-01-01
In vitro and animal studies suggest a possible role for the tetracycline class of drugs in the inhibition of non-enzymatic protein glycation. We conducted a 3-month, randomized placebo-controlled pilot clinical trial of conventional sub-gingival debridement, (periodontal therapy) combined with either a three month regimen of sub-antimicrobial-dose doxycycline (SDD), a two week regimen of antimicrobial-dose doxycycline (ADD), or placebo in 45 patients with long-standing type 2 diabetes (mean duration 9 years) and untreated chronic periodontitis. Subjects were taking stable doses of oral hypoglycemic medications and/or insulin. Treatment response was assessed by measuring hemoglobin A1c (HbA1c),plasma glucose, and clinical periodontal disease measures. At one-month and three-month follow-up, clinical measures of periodontitis were decreased in all groups(data to be presented elsewhere). At three months, mean HbA1c levels in the SDD group were reduced 0.9% unitsfrom 7.2% units ± 2.2(±SD), to 6.3% units ±1.1, which represents a 12.5% improvement. In contrast, there was no significant change in HbA1c in the ADD (7.5%± 2.0 to 7.8%± 2.1) or placebo (8.5%± 2.0 to 8.5%± 2.6) groups. Mean HbA1c change from baseline was significantly greater in the SDD group compared with the ADD group (p=0.04) but not placebo (p=0.22). Moreover, a larger proportion of subjects in the SDD group experienced improvement (p<0.05) compared to the ADD or placebo groups. Mean plasma glucose levels were not significantly different between or within the groups. The results of this pilot study suggest that the treatment of periodontitis with sub-gingival debridement and 3-months of daily sub-antimicrobial-dose doxycycline may decrease HbA1c in patients with type 2 diabetes taking normally prescribed hypoglycemic agents. PMID:21782948
2013-01-01
Introduction Colonisation of the lower respiratory tract with Candida species occurs in 25% of mechanically ventilated critically ill patients, and is associated with increased morbidity. Nebulised amphotericin B has been used to eradicate Candida as part of selective decontamination of the digestive tract (SDD) protocols, but its effectiveness is unknown. We aimed to determine the effectiveness of nebulised amphotericin B in eradicating Candida respiratory tract colonisation in patients receiving SDD. Methods We included consecutive mechanically ventilated patients during a four-year period. Microbiological screening was performed upon admission and twice weekly thereafter according to a standardised protocol. A colonisation episode was defined as the presence of Candida species in two consecutive sputum samples taken at least one day apart. To correct for time-varying bias and possible confounding, we used a multistate approach and performed time-varying Cox regression with adjustment for age, disease severity, Candida load at baseline and concurrent corticosteroid use. Results Among 1,819 patients, colonisation with Candida occurred 401 times in 363 patients; 333 of these events were included for analysis. Decolonisation occurred in 51 of 59 episodes (86%) and in 170 of 274 episodes (62%) in patients receiving and not receiving nebulised amphotericin B, respectively. Nebulised amphotericin B was associated with an increased rate of Candida eradication (crude HR 2.0; 95% CI 1.4 to 2.7, adjusted HR 2.2; 95% CI 1.6 to 3.0). Median times to decolonisation were six and nine days, respectively. The incidence rate of ventilator-associated pneumonia, length of stay and mortality did not differ between both groups. Conclusions Nebulised amphotericin B reduces the duration of Candida colonisation in the lower respiratory tracts of mechanically ventilated critically ill patients receiving SDD, but data remain lacking that this is associated with a meaningful improvement in clinical outcomes. Until more evidence becomes available, nebulised amphotericin B should not be used routinely as part of the SDD protocol. PMID:24119707
Antibiotic prophylaxis in the era of multidrug-resistant bacteria.
Wittekamp, Bastiaan H J; Bonten, Marc J M
2012-06-01
The prophylactic use of antibiotics can only be justified when clinical benefits on relevant patient outcomes, such as morbidity or mortality, cost-effectiveness, and absence of immediate emergence of antibiotic resistance have been unequivocally demonstrated. In some intensive care unit (ICU) patients, antibiotic prophylaxis is used as part of selective digestive tract decontamination (SDD) and selective oropharyngeal decontamination (SOD). Recent trials in ICUs with low levels of antibiotic resistance strongly suggest that both regimens reduce the incidence of ICU-acquired infections and improve patient survival. Naturally, the unique microbial ecology of such settings reduce generalizability of results. Therefore, the routine use of SOD and SDD remains highly controversial, especially in ICUs with higher levels of antibiotic resistance. Moreover, convincing evidence is still missing on several important aspects related to efficacy and safety. Despite numerous trials, effects of SDD and SOD on antibiotic resistance during and after decolonization treatment have still been insufficiently investigated, and existing results are contradicting. Furthermore, the effects of both regimens on the non-culturable part of the intestinal flora remain unknown. Finally, cost-effectiveness has not been thoroughly investigated, and prices of the antimicrobial agents that have been used have increased dramatically in recent years. In this review, important knowledge gaps that so far prevent the widespread use of SDD and SOD will be addressed.
Implementing Same Day Discharge Following Percutaneous Coronary Intervention: A Process Evaluation.
Chen, Yingyan; Lin, Frances; Marshall, Andrea
2018-06-14
The safety and effectiveness of same day discharge (SDD) following percutaneous coronary intervention are well demonstrated; however, the uptake of this model of care is low. The aim was to examine the effectiveness of implementing SDD using a process evaluation methodology. This study was undertaken in a cardiac services department of a tertiary teaching hospital in southeast Queensland, Australia. It was anticipated before the implementation that 120 patients could be discharged the same day in a 6 months' time period. Patient selection process and guideline adherence were assessed along with patients' and relatives' satisfaction. During implementation, 22 patients were discharged home the same day. It was found that staff did not follow the guideline consistently, with an overall adherence of 77.3%. The uptake of SDD was low in this implementation. The study is important as it provides direction for future improvement both in the criteria and the implementation process.
NASA Technical Reports Server (NTRS)
Hatfield, J. L.; Millard, J. P.; Reginato, R. J.; Jackson, R. D.; Idso, S. B.; Pinter, P. J., Jr.; Goettelman, R. C.
1980-01-01
Crop stress measured using thermal infrared emission is evaluated with the stress-degree-day (SDD) concept. Throughout the season, the accumulation of SDD during the reproductive stage of growth is inversely related to yield. This relationship is shown for durum wheat, hard red winter wheat, barley, grain sorghum and soybeans. It is noted that SDD can be used to schedule irrigations for maximizing yields and for applying remotely sensed data to management of water resources. An airborne flight with a thermal-IR scanner was used to examine the variability in temperature that may exist from one field to another and to determine realistic within-field temperature variations. It was found that the airborne and the ground-based data agreed very well and that there was less variability in the fields that were completely covered with crops than those of bare soil.
Towards Reducing the Data Exfiltration Surface for the Insider Threat
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlicher, Bob G; MacIntyre, Lawrence Paul; Abercrombie, Robert K
Unauthorized data exfiltrations from both insiders and outsiders are costly and damaging. Network communication resources can be used for transporting data illicitly out of the enterprise or cloud. Combined with built-in malware copying utilities, we define this as comprising the Data Exfiltration Surface (DXS). For securing valuable data, it is desirable to reduce the DXS and maintain controls on the egress points. Our approach is to host the data in a protected enclave that includes novel software Data Diode (SDD) installed on a secured, border gateway. The SDD allows copying data into the enclave systems but denies data from beingmore » copied out. Simultaneously, it permits remote access with remote desktop and console applications. Our tests demonstrate that we are able to effectively reduce the DXS and we are able to protect data from being exfiltrated through the use of the SDD.« less
NASA Astrophysics Data System (ADS)
Zhang, Xizhu; Wang, Jinshu; Wang, Yiman; Liu, Wei; Zhou, Meiling; Gao, Zhiyuan
2013-06-01
The microstructure of a fully activated scandia doped dispenser (SDD) cathode has been studied by scanning electron microscope (SEM). The observation results display that nanoparticles appear at the growth steps and the surface of tungsten grains of the fully activated SDD cathode. To study the influence of the nanoparticles on the emission, the local electric field strengths around the nanoparticles have been calculated by Maxwell 2D code and Comsol. The calculation results show that the local electric field strengths are enhanced by 1.1 to 3.8 times to average value based on different model conditions. The highest field strength is about 1.54 × 105 V/cm at an average field strength of 40 KV/cm, which is related to a space-charge limited (SCL) current density of 100 A/cm2 in the experimental configuration. This implies the field strength is not high enough to cause field emission.
NASA Astrophysics Data System (ADS)
Alsahli, Mohammad M. M.
Kuwait sea surface temperature (SST) and water clarity are important water characteristics that influence the entire Kuwait coastal ecosystem. The spatial and temporal distributions of these important water characteristics should be well understood to obtain a better knowledge about this productive coastal environment. The aim of this project was therefore to study the spatial and temporal distributions of: Kuwait SST using Moderate Resolution Imaging Spectroradiometer (MODIS) images collected from January 2003 to July 2007; and Kuwait Secchi Disk Depth (SDD), a water clarity measure, using Sea-viewing Wide Field-of-view Sensor (SeaWiFS) and MODIS data collected from November 1998 to October 2004 and January 2003 to June 2007, respectively. Kuwait SST was modeled based on the linear relationship between level 2 MODIS SST data and in situ SST data. MODIS SST images showed a significant relationship with in situ SST data ( r2= 0.98, n = 118, RMSE = 0.7°C). Kuwait SST images derived from MODIS data exhibited three spatial patterns of Kuwait SST across the year that were mainly attributed to the northwestern counterclockwise water circulation of the Arabian Gulf, and wind direction and intensity. The temporal variation of Kuwait SST was greatly influenced by the seasonal variation of solar intensity and air temperatures. Kuwait SDD was measured through two steps: first, computing the diffuse light attenuation coefficient at 490 nm, Kd(490), and 488 nm, Kd(488), derived from SeaWiFS and MODIS, respectively, using a semi-analytical algorithm; second, establishing two SDD models based on the empirical relationship of Kd(490) and Kd(488) with in situ SDD data. Kd(490) and Kd(488) showed a significant relationship with in situ SDD data ( r2= 0.67 and r2= 0.68, respectively). Kuwait SDD images showed distinct spatial and temporal patterns of Kuwait water clarity that were mainly attributed to three factors: the Shatt Al-Arab discharge, water circulation, and coastal currents. The SeaWiFS and MODIS data compared to in situ measurements provided a comprehensive view of the studied seawater characteristics that improved their overall estimation within Kuwait's waters. Also, the near-real-time availability of SeaWiFS and MODIS data and their highly temporal resolution make them a very advantageous tool for studying coastal environments. Thus, I recommend involving this method in monitoring Kuwait coastal environments.
The gastrointestinal tract and ventilator-associated pneumonia.
Kallet, Richard H; Quinn, Thomas E
2005-07-01
The gastrointestinal tract is believed to play an important role in ventilator-associated pneumonia (VAP), because during critical illness the stomach often is colonized with enteric Gram-negative bacteria. These are the same bacteria that frequently are isolated from the sputum of patients with VAP. Interventions such as selective decontamination of the digestive tract (SDD), use of sucralfate for stress ulcer prophylaxis, and enteral feeding strategies that preserve gastric pH, or lessen the likelihood of pulmonary aspiration, are used to decrease the incidence of VAP. A review of both meta-analyses and large randomized controlled trials providing Level I evidence on these topics has led to the following conclusions. First, SDD substantially decreases the incidence of VAP and may have a modest positive effect on mortality. However, there is strong contravening evidence that SDD promotes infections by Gram-positive bacteria. In the context of an emerging public health crisis from the steady rise in drug-resistant Gram-positive bacteria, we cannot endorse the general use of SDD to prevent VAP. Rather, therapy should be focused on strategies other than antibiotic prophylaxis. Second, in patients who are at risk for clinically important gastrointestinal bleeding, a histamine-2 receptor antagonist should be used for stress ulcer prophylaxis, rather than sucralfate, because histamine-2 receptor antagonist provides substantially better protection without substantially increasing the risk of VAP. Third, post-pyloric enteral feeding may reduce the incidence of VAP.
Fan, Tao; Zhao, HaiJun; Zhao, XinGang; Liang, Cong; Wang, YinQian; Gai, QiFei
2017-10-01
Chiari I malformation has been shown to present different cerebrospinal fluid (CSF) flow patterns at the cranial-vertebral junction (CVJ). Posterior fossa decompression is the first-line treatment for symptomatic Chiari I malformation. However, there is still controversy on the indication and selection of decompression procedures. This research aims to investigate the clinical indications, outcomes, and complications of the decompression procedures as alternative treatments for Chiari I malformation, based on the different CSF flow patterns at the cranial-vertebral junction. In this study, 126 Chiari I malformation patients treated with the two decompression procedures were analyzed. According to the preoperative findings obtained by using cine phase-contrast MRI (cine PC-MRI), the abnormal CSF flow dynamics at the CVJ in Chiari I malformation was classified into three patterns. After a preoperative evaluation and an intraoperative ultrasound after craniectomy, the two procedures were alternatively selected to treat the Chiari I malformation. The indication and selection of the two surgical procedures, as well as their outcomes and complications, are reported in detail in this work. Forty-eight patients underwent subdural decompression (SDD), and 78 received subarachnoid manipulation (SAM). Ninety patients were diagnosed as having Chiari I malformation with a syrinx. Two weeks after the operation, the modified Japanese Orthopedic Association (mJOA) scores increased from the preoperative value of 10.67 ± 1.61 to 12.74 ± 2.01 (P < 0.01). The mean duration of follow-up was 24.8 months; the mJOA scores increased from the postoperative value of 12.74 ± 2.01 to 12.79 ± 1.91 at the end of follow-up (P = 0.48). More complications occurred in the patients who underwent SAM than in those who received SDD (SAM 11 of 78 (9.5%) vs SDD 2 of 48 (3.5%)). The abnormal CSF flow dynamics at the CVJ in Chiari I malformation can be classified into three patterns. A SAM procedure is more feasible in Chiari I malformation (CM1) patients with pattern III CSF flow dynamics, whereas a SDD procedure is more suitable for CM1 patients with pattern I CSF flow dynamics. In CM1 patients with pattern II CSF flow dynamics, an intraoperative ultrasound after craniectomy could play an important role in the selection of an effective decompression procedure.
Quirk, Emma; Doggett, Adrian; Bretnall, Alison
2014-08-05
Spray Dried Dispersions (SDD) are uniform mixtures of a specific ratio of amorphous active pharmaceutical ingredient (API) and polymer prepared via a spray drying process. Volatile solvents are employed during spray drying to facilitate the formation of the SDD material. Following manufacture, analytical methodology is required to determine residual levels of the spray drying solvent and its associated impurities. Due to the high level of polymer in the SDD samples, direct liquid injection with Gas Chromatography (GC) is not a viable option for analysis. This work describes the development and validation of an analytical approach to determine residual levels of acetone and acetone related impurities, mesityl oxide (MO) and diacetone alcohol (DAA), in drug product intermediates prepared as SDDs using GC with headspace (HS) autosampling. The method development for these analytes presented a number of analytical challenges which had to be overcome before the levels of the volatiles of interest could be accurately quantified. GCHS could be used after two critical factors were implemented; (1) calculation and application of conversion factors to 'correct' for the reactions occurring between acetone, MO and DAA during generation of the headspace volume for analysis, and the addition of an equivalent amount of polymer into all reference solutions used for quantitation to ensure comparability between the headspace volumes generated for both samples and external standards. This work describes the method development and optimisation of the standard preparation, the headspace autosampler operating parameters and the chromatographic conditions, together with a summary of the validation of the methodology. The approach has been demonstrated to be robust and suitable to accurately determine levels of acetone, MO and DAA in SDD materials over the linear concentration range 0.008-0.4μL/mL, with minimum quantitation limits of 20ppm for acetone and MO, and 80ppm for DAA. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Newbury, D. E.
2006-05-01
X-ray mapping, performed with the electron probe microanalyzer (EPMA) or scanning electron microscope/energy dispersive x-ray spectrometer (SEM/EDS), is one of the most popular modes of studying chemically heterogeneous microstructures [1]. Despite the maturity of the technique, now in its 50th anniversary year [2], recent remarkable advances in instrumentation and software will provide microanalysts with an even more effective and efficient microstructural characterization tool: (1) Increased x-ray mapping speed: The silicon drift detector (SDD) [3] is a new form of the familiar silicon EDS that uses the same detection physics but with a radically different design that outperforms the classic Si-EDS in nearly every way [4]: (1) the SDD operates requires only Peltier cooling to -20 oC to - 50 oC; (2) for a given detector active area, the SDD has superior resolution; (3) the SDD achieves the same resolution but with a peaking time that is 5 to 8 times faster; and (4) maximum output count rate (OCR) ranges from about 14 kHz at optimum resolution (134 eV at MnKa for a 50 mm2 area) to 500 kHz (217 eV). This OCR performance enables rapid x-ray mapping collection in the x-ray spectrum image (XSI) mode, in which a complete EDS spectrum (2048 10eV-channels) is captured at each pixel (e.g., 10 ms dwell with 1.3 ms overhead per pixel, or 185 seconds for a 128x128 pixel map). XSI collection captures all possible spectral information within the limits imposed by the spectrometer and the primary beam dose. (2) EDS with WDS resolution: The microcalorimeter EDS measures the temperature rise when a single x-ray photon is absorbed in a metal target [5]. Demonstrated resolution is 4.5 eV at Mn Ka for a broad energy range (0.2 - 10 keV) spectrometer and 2 eV (AlKa) for a low photon energy range (0.2 - 2.0 keV) version. The low energy spectrometer is sensitive to peak shape and position changes associated with chemical bonding, opening the possibility of EDS chemical-state mapping. (3) Data mining: In the XSI mode, data is captured at the rate of 100 Mbytes per XSI database or more. Efficient software tools have been developed that enable the analyst to quickly recognize major and minor constituent features in this datacube, and even to detect rare unexpected features that occur at only one pixel in a large map [6]. Advanced image cube data reduction can be achieved with tools based on statistical methods, such as principal component analysis, that quickly establishes correlations between different elements, such as distinct phases [7]. 1. Goldstein, J., Newbury, D., Joy, D., Lyman, C., Echlin, P., Lifshin, E., Sawyer, L., and Michael, J., Scanning Electron Microscopy and X-ray Microanalysis, 3rd edition (Kluwer Academic Plenum Press, New York, 2003). 2. Cosslett, E. and P. Duncumb, Nature, 177 (1956) 1172. 3. Struder, L., Fiorini, C., Gatti, E., Hartmann, R., Holl, P., Krause, N., Lechner, P., Longoni, A., Lutz, G., Kemmer, J., Meidinger, N., Popp, M., Soltau, H., and van Zanthier, C., High resolution non dispersive x-ray spectroscopy with state of the art silicon detectors, Mikrochim. Acta, Suppl, 15 (1998) 11 4. Newbury, D. SCANNING, 27 (2005) 227. 5. Wollman, D., Irwin, K., Hilton, G., Dulcie, L., Newbury, D., and Martinis, J., J. Micros. 188 (1997) 196. 6. Newbury, D. and Bright, D., SCANNING, 27 (2005) 15. 7. Kotula, P. Keenan, M., and Michael J., Micros. Microanal. 9 (2003) 1
A Synchronous Digital Duplexing Technique for OFDMA-Based Indoor Communications
NASA Astrophysics Data System (ADS)
Park, Chang-Hwan; Ko, Yo-Han; Kim, Yeong-Jun; Park, Kyung-Won; Jeon, Won-Gi; Paik, Jong-Ho; Lee, Seok-Pil; Cho, Yong-Soo
In this paper, we propose a new digital duplexing scheme, called synchronous digital duplexing (SDD), which can increase data efficiency and flexibility of resource by transmitting uplink signal and downlink signal simultaneously in wireless communication. In order to transmit uplink and downlink signals simultaneously, the proposed SDD obtains mutual information among subscriber stations (SSs) with a mutual ranging symbol. This information is used for selection of transmission time, decision on cyclic suffix (CS) insertion, determination of CS length, and re-establishment of FFT starting point.
System Design Description for the TMAD Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finfrock, S.H.
This document serves as the System Design Description (SDD) for the TMAD Code System, which includes the TMAD code and the LIBMAKR code. The SDD provides a detailed description of the theory behind the code, and the implementation of that theory. It is essential for anyone who is attempting to review or modify the code or who otherwise needs to understand the internal workings of the code. In addition, this document includes, in Appendix A, the System Requirements Specification for the TMAD System.
Leane, Michael M; Sinclair, Wayne; Qian, Feng; Haddadin, Raja; Brown, Alan; Tobyn, Mike; Dennis, Andrew B
2013-01-01
Amorphous forms of poorly soluble drugs are more frequently being incorporated into solid dispersions for administration and extensive research has led to a reasonable understanding of how these dispersions, although still kinetically unstable, improve stability relative to the pure amorphous form. There remains however a paucity of literature describing the effects on such solid dispersions of subsequent processing into solid dosage forms such as tablets. This paper addresses this area by looking at the effects of the addition of common excipients and different manufacturing routes on the stability of a spray-dried dispersion (SDD) of the cannabinoid CB-1 antagonist, ibipinabant. A marked difference in physical stability of tablets was seen with the different fillers with microcrystalline cellulose (MCC) giving the best stability profile. It was found that minimising the number of compression steps led to improved formulation stability with a direct compression process giving the best results. Increased levels of crystallinity were seen in coated tablets most likely due to the exposure of the amorphous matrix to moisture and heat during the coating process. DSIMS analysis of the SDD particles indicated increased levels of polymer on the surface.
Singular Hopf bifurcation in a differential equation with large state-dependent delay
Kozyreff, G.; Erneux, T.
2014-01-01
We study the onset of sustained oscillations in a classical state-dependent delay (SDD) differential equation inspired by control theory. Owing to the large delays considered, the Hopf bifurcation is singular and the oscillations rapidly acquire a sawtooth profile past the instability threshold. Using asymptotic techniques, we explicitly capture the gradual change from nearly sinusoidal to sawtooth oscillations. The dependence of the delay on the solution can be either linear or nonlinear, with at least quadratic dependence. In the former case, an asymptotic connection is made with the Rayleigh oscillator. In the latter, van der Pol’s equation is derived for the small-amplitude oscillations. SDD differential equations are currently the subject of intense research in order to establish or amend general theorems valid for constant-delay differential equation, but explicit analytical construction of solutions are rare. This paper illustrates the use of singular perturbation techniques and the unusual way in which solvability conditions can arise for SDD problems with large delays. PMID:24511255
Singular Hopf bifurcation in a differential equation with large state-dependent delay.
Kozyreff, G; Erneux, T
2014-02-08
We study the onset of sustained oscillations in a classical state-dependent delay (SDD) differential equation inspired by control theory. Owing to the large delays considered, the Hopf bifurcation is singular and the oscillations rapidly acquire a sawtooth profile past the instability threshold. Using asymptotic techniques, we explicitly capture the gradual change from nearly sinusoidal to sawtooth oscillations. The dependence of the delay on the solution can be either linear or nonlinear, with at least quadratic dependence. In the former case, an asymptotic connection is made with the Rayleigh oscillator. In the latter, van der Pol's equation is derived for the small-amplitude oscillations. SDD differential equations are currently the subject of intense research in order to establish or amend general theorems valid for constant-delay differential equation, but explicit analytical construction of solutions are rare. This paper illustrates the use of singular perturbation techniques and the unusual way in which solvability conditions can arise for SDD problems with large delays.
Analysis of the spatio-temporal variability of seawater quality in the southeastern Arabian Gulf.
Mezhoud, Nahla; Temimi, Marouane; Zhao, Jun; Al Shehhi, Maryam Rashed; Ghedira, Hosni
2016-05-15
In this study, seawater quality measurements, including salinity, sea surface temperature (SST), chlorophyll-a (Chl-a), Secchi disk depth (SDD), pH, and dissolved oxygen (DO), were made from June 2013 to November 2014 at 52 stations in the southeastern Arabian Gulf. Significant variability was noticed for all collected parameters. Salinity showed a decreasing trend, and Chl-a, DO, pH, and SDD demonstrated increasing trends from shallow onshore stations to deep offshore ones, which could be attributed to variations of ocean circulation and meteorological conditions from onshore to offshore waters, and the likely effects of desalination plants along the coast. Salinity and temperature were high in summer and low in winter while Chl-a, SDD, pH, and DO indicated an opposite trend. The CTD profiles showed vertically well-mixed structures. Qualitative analysis of phytoplankton showed a high diversity of species without anomalous species found except in Ras Al Khaimah stations where diatoms were the dominating ones. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhang, H.; Zhou, Y. P.; Peng, H. J.; Zhang, X. H.; Zhou, F. Y.; Liu, Z. H.; Chen, X. G.
2014-01-01
The aim of the meta-analysis was to provide more solid evidence for the reliability of the new classification. A systematic literature search was performed using PubMed, Armed Forces Pest Management Board Literature Retrieval System, and Google Scholar up to August 2012. A pooled odds ratio (OR) was calculated using either a random-effect or a fixed-effect model. A total of 16 papers were identified. Among the 11 factors studied, five symptoms demonstrated an increased risk for SDD, including bleeding [OR: 13.617; 95% confidence interval (CI): 3.281, 56.508], vomiting/nausea (OR: 1.692; 95% CI: 1.256, 2.280), abdominal pain (OR: 2.278; 95% CI: 1.631, 3.182), skin rashes (OR: 2.031; 95% CI: 1.269, 3.250), and hepatomegaly (OR: 4.751; 95% CI: 1.769, 12.570). Among the four bleeding-related symptoms including hematemesis, melena, gum bleeding, and epistaxis, only hematemesis (OR: 6.174; 95% CI: 2.66, 14.334; P < 0.001) and melena (OR: 10.351; 95% CI: 3.065, 34.956; P < 0.001) were significantly associated with SDD. No significant associations with SDD were found for gender, lethargy, retroorbital pain, diarrhea, or tourniquet test, whereas headache appeared protective (OR: 0.555; 95% CI: 0.455, 0.676). The meta-analysis suggests that bleeding (hematemesis/melena), vomiting/nausea, abdominal pain, skin rashes, and hepatomegaly may predict the development of SDD in patients with DF, while headache may predict otherwise. PMID:25097856
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Z; Wang, J; Peng, J
Purpose: Electronic portal imaging device (EPID) can be used to acquire a two-dimensional exit dose distribution during treatment delivery, thus allowing the in-vivo verification of the dose delivery through a comparison of measured portal images to predicted portal dose images (PDI). The aim of this study was to present a novel method to easily and accurately predict PDI, and to establish an EPID-based in-vivo dose verification method during IMRT treatments. Methods: We developed a model to determine the predicted portal dose at the same plane of the EPID detector location. The Varian EPID (aS1000) positions at 150cm source-to-detector-distance (SDD), andmore » can be used to acquire in-vivo exit dose using Portal Dosimetry (PD) function. Our model was generated to make an equivalent water thickness represent the buildup plate of EPID. The exit dose at extend SDD plane with patient CT data in the beam can be calculated as the predicted PDI in the treatment planning system (TPS). After that, the PDI was converted to the fluence at SDD of 150cm using the inverse square law coded in MATLAB. Five head-and-neck and prostate IMRT patient plans contain 32 fields were investigated to evaluate the feasibility of this new method. The measured EPID image was compared with PDI using the gamma analysis. Results: The average results for cumulative dose comparison were 81.9% and 91.6% for 3%, 3mm and 4%, 4mm gamma criteria, respectively. Results indicate that the patient transit dosimetry predicted algorithm compares well with EPID measured PD doses for test situations. Conclusion: Our new method can be used as an easy and feasible tool for online EPID-based in-vivo dose delivery verification for IMRT treatments. It can be implemented for fast detecting those obvious treatment delivery errors for individual field and patient quality assurance.« less
Cargo Movement Operations System (CMOS). Final Software Product Specification Increment 1
1991-02-17
NO ( ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ ] CLOSED [ ] ORIGINATOR CONTROL NUMBER: SPSl-0002 PROGRAM OFFICE CONTROL NUMBER: DATA ITEM DISCREPANCY WORKSHEET CDRI NUMBER: A014-02 DATE: 02/17/91 ORIGINATOR NAME: Vivian L. Martin OFFICE SYMBOL: SAIC TELEPHONE NUMBER: 272-2999 SUBSTANTIVE: X EDITORIAL: PAGE NUMBER: E-1 PARA NUMBER: 10. COMMENT OR RECOMMENDED CHANGE: Footnote the AUTOEXEC.BAT entry to indicate that it is identified as CUlAO001 in the SDD (20 Dec 90). RATIONALE: This will synchronize the SPS with the SDD. CMOS PMO ACCEPTS
Studenic, Paul; Stamm, Tanja; Smolen, Josef S; Aletaha, Daniel
2016-01-01
Patient-reported outcomes (PROs) such as pain, patient global assessment (PGA) and fatigue are regularly assessed in RA patients. In the present study, we aimed to explore the reliability and smallest detectable differences (SDDs) of these PROs, and whether the time between assessments has an impact on reliability. Forty RA patients on stable treatment reported the three PROs daily over two subsequent months. We assessed the reliability of these measures by calculating intraclass correlation coefficients (ICCs) and the SDDs for 1-, 7-, 14- and 28-day test-retest intervals. Overall, SDD and ICC were 25 mm and 0.67 for pain, 25 mm and 0.71 for PGA and 30 mm and 0.66 for fatigue, respectively. SDD was higher with longer time period between assessments, ranging from 19 mm (1-day intervals) to 30 mm (28-day intervals) for pain, 19 to 33 mm for PGA, and 26 to 34 mm for fatigue; correspondingly, ICC was smaller with longer intervals, and ranged between the 1- and the 28-day interval from 0.80 to 0.50 for pain, 0.83 to 0.57 for PGA and 0.76 to 0.58 for fatigue. The baseline simplified disease activity index did not have any influence on reliability. Lower baseline PRO scores led to smaller SDDs. Reliability of pain, PGA and fatigue measurements is dependent on the tested time interval and the baseline levels. The relatively high SDDs, even for patients in the lowest tertiles of their PROs, indicate potential issues for assessment of the presence of remission. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Rachevski, Alexandre; Ahangarianabhari, Mahdi; Bellutti, Pierluigi; Bertuccio, Giuseppe; Brigo, Elena; Bufon, Jernej; Carrato, Sergio; Castoldi, Andrea; Cautero, Giuseppe; Fabiani, Sergio; Giacomini, Gabriele; Gianoncelli, Alessandra; Giuressi, Dario; Guazzoni, Chiara; Kourousias, George; Liu, Chang; Menk, Ralf Hendrik; Montemurro, Giuseppe Vito; Picciotto, Antonino; Piemonte, Claudio; Rashevskaya, Irina; Shi, Yongbiao; Stolfa, Andrea; Vacchi, Andrea; Zampa, Gianluigi; Zampa, Nicola; Zorzi, Nicola
2016-07-01
We developed a trapezoidal shaped matrix with 8 cells of Silicon Drift Detectors (SDD) featuring a very low leakage current (below 180 pA/cm2 at 20 °C) and a shallow uniformly implanted p+ entrance window that enables sensitivity down to few hundreds of eV. The matrix consists of a completely depleted volume of silicon wafer subdivided into 4 square cells and 4 half-size triangular cells. The energy resolution of a single square cell, readout by the ultra-low noise SIRIO charge sensitive preamplifier, is 158 eV FWHM at 5.9 keV and 0 °C. The total sensitive area of the matrix is 231 mm2 and the wafer thickness is 450 μm. The detector was developed in the frame of the INFN R&D project ReDSoX in collaboration with FBK, Trento. Its trapezoidal shape was chosen in order to optimize the detection geometry for the experimental requirements of low energy X-ray fluorescence (LEXRF) spectroscopy, aiming at achieving a large detection angle. We plan to exploit the complete detector at the TwinMic spectromicroscopy beamline at the Elettra Synchrotron (Trieste, Italy). The complete system, composed of 4 matrices, increases the solid angle coverage of the isotropic photoemission hemisphere about 4 times over the present detector configuration. We report on the layout of the SDD matrix and of the experimental set-up, as well as the spectroscopic performance measured both in the laboratory and at the experimental beamline.
van Saene, Hendrick K F; Petros, Andy J; Ramsay, Graham; Baxby, Derrick
2003-05-01
The objective was to compare evidence of the effectiveness, costs and safety of the traditional parenteral antibiotic-only approach against that gathered from 53 randomised trials involving more than 8,500 patients and six meta-analyses on selective decontamination of the digestive tract (SDD) to control infection on the intensive care unit (ICU). PHILOSOPHY: Traditionalists believe that all infections are due to breaches of hygiene except those established in the first 2 days, and that all micro-organisms can cause death. In contrast, newer insights show that transmission via the hands of carers are responsible only for infections occurring after one week, and that only a limited range of 15 potential pathogens contribute to mortality. INTERVENTIONS TO PREVENT ICU INFECTION: The traditional approach is based on hand disinfection aiming at the prevention of transmission of all micro-organisms, to control all infections that occur after 2 days on the ICU. The second feature is the restrictive use of systemic antibiotics, only in cases of microbiologically proven infection. In contrast, SDD aims to control the three types of infection: primary, secondary endogenous and exogenous due to 15 potential pathogens. The classical SDD tetralogy comprises four components: (i) a parenteral antibiotic, cefotaxime, administered for three days to prevent primary endogenous infections typically occurring "early"; (ii) the oropharyngeal and enteral antimicrobials, polymyxin E, tobramycin and amphotericin B administered in throat and gut throughout the treatment on the ICU to prevent secondary endogenous infections tending to develop "late"; (iii) a high standard of hygiene to control transmission of potential pathogens; and (iv) surveillance samples of throat and rectum to monitor the efficacy of the treatment. (i) Infectious morbidity; (ii) mortality; (iii) antimicrobial resistance; and (iv) costs. Properly designed trials on hand disinfection have never demonstrated a reduction in either pneumonia and septicaemia, or mortality. Two randomised trials using restrictive antibiotic policies failed to show a survival benefit at 28 days. In both trials the proportion of resistant isolates obtained from the lower ways was >60% despite significantly less use of antibiotics in the test group. A formal cost effectiveness analysis of the traditional antibiotic policies has not been performed. On the other hand, two meta-analyses have shown that SDD reduces the odds ratio for lower airway infections to 0.35 (0.29-0.41) and mortality to 0.80 (0.69-0.93), with a 6% overall mortality reduction from 30% to 24%. No increase in the rate of super infections due to resistant bacteria could be demonstrated over a period of 20 years of clinical research. Four randomised trials found the cost per survivor to be substantially lower in patients receiving SDD than for those traditionally managed. The traditionalists still rely on level 5 evidence, i.e. expert opinion, with a grade E recommendation, whilst the proponents of SDD are able to cite level 1 evidence allowing a grade A recommendation in their attempts to control infection on the ICU. The main reason for SDD not being widely used is the primacy of opinion over evidence.
Modification of the degree-day formula for diurnal meltwater generation and refreezing
NASA Astrophysics Data System (ADS)
Žaknić-Ćatović, Ana; Howard, Ken W. F.; Ćatović, Zlatko
2018-02-01
The standard degree-day, temperature-index approach to calculating snowmelt generation and refreezing (the SDD method) is convenient and popularly used but seriously miscalculates the volumes of water that change phase on days when temperatures fluctuate either side of the freezing point. Additionally, the SDD method does not provide any estimate of the duration of daily melting and refreezing events. A modified version of the standard formula is introduced (the MDD method) that overcomes such problems by removing dependence on a single temperature index (the average daily temperature estimated over a 24-h period beginning at midnight) and instead transfers reliance onto daily air temperature extremes (maximum and minimum temperatures) at known times of occurrence. In this way, the modified formula retains the simplicity of the standard approach while targeting those segments of the diurnal air temperature curve that directly relate to periods of melting and freezing. Newly introduced temperature and time degree-day parameters allow the duration of melting and refreezing events to be estimated. The MDD method was evaluated for two sites in the snow-belt region of Canada where the availability of hourly records of daily temperature allowed the required MDD input parameters to be calculated reliably and thus used for comparative purposes. During testing, the MDD input parameters were obtained from daily temperature extremes and their times of occurrence, using two alternative approaches to synthetic air temperature curve generation, one linear, the other trigonometric. Very good agreement was obtained in both cases and confirms the value of the MDD approach. However, there is no significant benefit to be gained by using air temperature approximating functions more complicated than the linear method for supplementing the missing continuous air temperature measurements. Finally, the MDD approach is not seen as a replacement for the regular SDD method, so much as tool that can be applied when the SDD methodology is likely to become unreliable. This is best achieved by using a hybrid SDD-MDD algorithm that invokes the MDD approach only when the necessary conditions arise.
Parel, I; Cutti, A G; Fiumana, G; Porcellini, G; Verni, G; Accardo, A P
2012-04-01
To measure the scapulohumeral rhythm (SHR) in outpatient settings, the motion analysis protocol named ISEO (INAIL Shoulder and Elbow Outpatient protocol) was developed, based on inertial and magnetic sensors. To complete the sensor-to-segment calibration, ISEO requires the involvement of an operator for sensor placement and for positioning the patient's arm in a predefined posture. Since this can affect the measure, this study aimed at quantifying ISEO intra- and inter-operator agreement. Forty subjects were considered, together with two operators, A and B. Three measurement sessions were completed for each subject: two by A and one by B. In each session, the humerus and scapula rotations were measured during sagittal and scapular plane elevation movements. ISEO intra- and inter-operator agreement were assessed by computing, between sessions, the: (1) similarity of the scapulohumeral patterns through the Coefficient of Multiple Correlation (CMC(2)), both considering and excluding the difference of the initial value of the scapula rotations between two sessions (inter-session offset); (2) 95% Smallest Detectable Difference (SDD(95)) in scapula range of motion. Results for CMC(2) showed that the intra- and inter-operator agreement is acceptable (median≥0.85, lower-whisker ≥ 0.75) for most of the scapula rotations, independently from the movement and the inter-session offset. The only exception is the agreement for scapula protraction-retraction and for scapula medio-lateral rotation during abduction (inter-operator), which is acceptable only if the inter-session offset is removed. SDD(95) values ranged from 4.4° to 8.6° for the inter-operator and between 4.9° and 8.5° for the intra-operator agreement. In conclusion, ISEO presents a high intra- and inter-operator agreement, particularly with the scapula inter-session offset removed. Copyright © 2011 Elsevier B.V. All rights reserved.
Transradial PCI and Same Day Discharge.
Elfandi, Ali; Safirstein, Jordan G
2018-02-24
The evolution of cardiac catheterization has led to the development of well-refined, more effective, and safer devices that allow cardiovascular interventionalists to deliver high-quality percutaneous interventions (PCI). Transradial PCI (TRI) has gained more popularity in the USA over the past 10 years, and as experience and volume of TRI grow, studies adopting same day radial PCI protocols have emerged and are showing promising results. We sought to review the current literature on TRI and same day discharge (SDD). This literature review was performed to evaluate the studies that were published over the last 17 years regarding TRI and SDD. A literature search using PubMed, Cochran database, Google Scholar, and Embase was performed for studies evaluating TRI and SDD from January 1, 2000, to August 1, 2017. Observational studies, randomized clinical trials, meta-analyses, and consensus statements were included in our review. We used the following terms in our search: "same day," "same day discharge," "outpatient," and "ambulatory radial PCI." Articles with data pertinent to the subject matter were included. We did not limit our searches to specific journals. The available literature supports SDD for selected radial PCI patients. The advancement in PCI devices and pharmacology has enhanced the safety of post-PCI disposition leading to the evolution from traditional overnight stays to the development of same day discharge programs. We conclude that outpatient TRI for appropriately selected patients will be the standard of care in the future. This will lead to increased patient satisfaction, improved hospital throughput, and reduced hospital costs, without increased procedural complications.
The secondary drying and the fate of organic solvents for spray dried dispersion drug product.
Hsieh, Daniel S; Yue, Hongfei; Nicholson, Sarah J; Roberts, Daniel; Schild, Richard; Gamble, John F; Lindrud, Mark
2015-05-01
To understand the mechanisms of secondary drying of spray-dried dispersion (SDD) drug product and establish a model to describe the fate of organic solvents in such a product. The experimental approach includes characterization of the SDD particles, drying studies of SDD using an integrated weighing balance and mass spectrometer, and the subsequent generation of the drying curve. The theoretical approach includes the establishment of a Fickian diffusion model. The kinetics of solvent removal during secondary drying from the lab scale to a bench scale follows Fickian diffusion model. Excellent agreement is obtained between the experimental data and the prediction from the modeling. The diffusion process is dependent upon temperature. The key to a successful scale up of the secondary drying is to control the drying temperature. The fate of primary solvents including methanol and acetone, and their potential impurity such as benzene can be described by the Fickian diffusion model. A mathematical relationship based upon the ratio of diffusion coefficient was established to predict the benzene concentration from the fate of the primary solvent during the secondary drying process.
Silicon Drift Detector response function for PIXE spectra fitting
NASA Astrophysics Data System (ADS)
Calzolai, G.; Tapinassi, S.; Chiari, M.; Giannoni, M.; Nava, S.; Pazzi, G.; Lucarelli, F.
2018-02-01
The correct determination of the X-ray peak areas in PIXE spectra by fitting with a computer program depends crucially on accurate parameterization of the detector peak response function. In the Guelph PIXE software package, GUPIXWin, one of the most used PIXE spectra analysis code, the response of a semiconductor detector to monochromatic X-ray radiation is described by a linear combination of several analytical functions: a Gaussian profile for the X-ray line itself, and additional tail contributions (exponential tails and step functions) on the low-energy side of the X-ray line to describe incomplete charge collection effects. The literature on the spectral response of silicon X-ray detectors for PIXE applications is rather scarce, in particular data for Silicon Drift Detectors (SDD) and for a large range of X-ray energies are missing. Using a set of analytical functions, the SDD response functions were satisfactorily reproduced for the X-ray energy range 1-15 keV. The behaviour of the parameters involved in the SDD tailing functions with X-ray energy is described by simple polynomial functions, which permit an easy implementation in PIXE spectra fitting codes.
Kaliaperumal, Chandrasekaran; Khalil, Ayman; Fenton, Eoin; Okafo, Uchenna; Kaar, George; O'Sullivan, Michael; Marks, Charles
2012-11-01
The usage of a drain following evacuation of a chronic subdural haematoma (CSDH) is known to reduce recurrence. In this study we aim to compare the clinical outcomes and recurrence rate of utilising two different types of drains (subperiosteal and subdural drain) following drainage of a CSDH. Prospective randomised single-centre study analysing 50 patients who underwent CSDH treatment. Two types of drains, subperiosteal (SPD) and subdural (SDD), were utilised on consecutive alternate patients following burr-hole craniostomy, with a total of 25 patients in each group. The drains were left in for 48-h duration and then removed. The modified Rankin Scale (mRS) was used for outcome measurement at 3 and 6 months. Data analysis was performed by unpaired t test with Welch's correction. It was observed that none of the patients in either group had haematoma recurrence during a 6-month follow-up, and a significant difference in outcome was noted at 6 months (p = 0.0118) more than at 3 months (p = 0.0493) according to the statistical analysis. Postoperative seizure and inadvertent placement of the subdural drain into the brain parenchyma were the two complications noted in this study. Anticoagulant use prior to the surgery did not affect the outcome in either group. We conclude there was no recurrence of CSDH utilising the SDD and SPD following burr-hole craniostomy. The mRS measurement at the 6-month follow-up was found to be statistically significant, with better outcomes with utilisation of the SPD. The SPD may thus prove to be more beneficial than the SDD in the treatment of CSDH. A multi-centre study with a larger group of patients is recommended to reinforce the results from our study.
Noninvasive methods for haemoglobin screening in prospective blood donors.
Belardinelli, A; Benni, M; Tazzari, P L; Pagliaro, P
2013-08-01
The haemoglobin level of prospective blood donors is usually performed on blood obtained by from the finger pulp by fingerstick with a lancet and filling a capillary tube with a sample. New noninvasive methods are now available for rapid, noninvasive predonation haemoglobin screening. Prospective blood donors at our blood centre were tested, in two different trials, as follows: by the NBM 200 (OrSense) test (n = 445 donors) and by the Pronto-7 (Masimo) test (n = 463 donors). The haemoglobin values of each trial and the haemoglobin of finger pulp blood obtained by fingerstick with a lancet (HemoCue) were compared with the haemoglobin values obtained from a venous sample on a Cell Counter (Beckman Coulter). Comparison of Beckman Coulter Cell Counter and OrSense and results showed a bias of 0.29 g/dl, the standard deviation of the differences (SDD) of 0.98 and 95% limits of agreement from -1.64 to 2.21, using Bland and Altman statistical methodology. Comparison of Masimo and Beckman Coulter Cell Counter results showed a bias of -0.53 g/dl, SDD of 1.04 and 95% limits of agreement from -2.57 to 1.51. Cumulative analysis of all 908 donors, as tested by the usual fingerstick test showed a bias of 0.83 g/dl, SDD of 0.70 and 95% limits of agreement from -0.54 to 2.20 compared with the Coulter Cell Counter. Compared with the Coulter Counter, the specificity of the methods was 99.5% for fingerstick, 97% for OrSense and 83% for Massimo, and the sensitivity was 99, 98 and 93%, respectively. Analysis of finger pulp blood by either direct sampling by fingerstick and Hemocue, or by noninvasive haemoglobin tests does not replicate the results of cell counter analysis of venous samples. Compared with fingerstick, noninvasive haemoglobin tests eliminate pain and reduce stress, but have a lower level of specificity and sensitivity. © 2013 International Society of Blood Transfusion.
Dosimetric studies of cadmium free alloy used in compensator based intensity modulated radiotherapy
NASA Astrophysics Data System (ADS)
Kaushik, Sandeep; Punia, Rajesh; Tyagi, Atul; Singh, Mann P.
2017-10-01
Aim of this study was to investigate dosimetric properties of cadmium free alloy which is used in compensator based intensity modulated radiotherapy (cIMRT). A mixture of lead, bismuth and tin was used to prepare the alloy whose melting point is 90-95 °C. Slabs of different thicknesses ranging from 0.71 cm to 6.14 cm were prepared. Density of alloy was measured by Archimedes' principle using water. For six megavolt (6 MV) photon beam energy transmission, linear effective attenuation coefficient (μeff), tissue phantom ratio (TPR1020), beam hardening, surface dose (Ds), percentage depth dose (PDD) and effect of scatter has been measured and analyzed for different field sizes and different thickness of compensator. Effect of extended source to detector distance (SDD) on transmissions and μeff was measured. The density of alloy was found to be 9.5456 g/cm3. At SDD of 100 cm, μeff was observed 0.4253 cm-1 for a field size of 10×10 cm 2. Calculated TPR1020 was found to be within 3% of experimental TPR1020 . It was found to be increasing with increasing thickness of compensator. Ds was found to decrease with thickness of compensator and increase with wider collimator opening due to increased scattered dose. Compensator slabs of 1 cm, 1.98 cm and 4.16 cm decreased surface dose by 4.2%, 6.1% and 9.5% respectively for a field size of 10×10 cm2 at 100 cm SDD. For small field size of 3×3 cm2 and 5×5 cm2 PDDs are increased from 3.0% to 5.5% of open beam PDDs as compensator thickness increased from 1 cm to 6.14 cm at a depth of 10 cm in water while variation in PDD is insignificant in for larger field sizes 10×10 cm2 to 20×20 cm2. A high degree of intensity modulation is essential in cIMRT and it can be achieved with this compensator material. Dosimetric properties analyzed in this study establish this alloy as a reliable, reusable, optimally dense and cost effective compensator material.
Boaz, Segal M.; Dominguez, Kenneth; Shaman, Jeffrey A.; Ward, W. Steven
2009-01-01
We demonstrated that mouse spermatozoa cleave their DNA into ~50 kb loop-sized fragments with topoisomerase IIB when treated with MnCl2 and CaCl2 in a process we term sperm chromatin fragmentation (SCF). SCF can be reversed by EDTA. A nuclease then further degrades the DNA in a process we term sperm DNA degradation (SDD). MnCl2 alone could elicit this activity, but CaCl2 had no effect. Here, we demonstrate the existence of a nuclease in the vas deferens that can be activated by EGTA to digest the sperm DNA by SDD. Spermatozoa were extracted with salt and dithiothreitol to remove protamines and then incubated with EGTA. Next, the EGTA was removed and divalent cations were added. We found that Mn+2, Ca+2, or Zn+2 could each activate SDD in spermatozoa but Mg+2 could not. When the reaction was slowed by incubation on ice, EGTA pretreatment followed by incubation in Ca+2 elicited the reversible fragmentation of sperm DNA evident in SCF. When the reactions were then incubated at 37°C they progressed to the more complete degradation of DNA by SDD. EDTA could also be used to activate the nuclease, but required a higher concentration than EGTA. This EGTA-activatable nuclease activity was found in each fraction of the vas deferens plasma: in the spermatozoa, in the surrounding fluid, and in the insoluble components in the fluid. These results suggest that this sperm nuclease is regulated by a mechanism that is sensitive to EGTA, possibly by removing inhibition of a calcium binding protein. PMID:17879959
2002-05-13
Mount • Install Large Capacity Ammo Container On Mount • Add Actuators And Resolvers For Laying OCSW Independent Of Main Gun t ti f t ti...FY07 FY08 FY09 FY10 FY11 FY12 4 5 6 SI Prod Block II (2K FLIR,Dual Feed, CPU Upgrade, AP Enhancements, MEMS) IOT &E LFT&E LUT...PQT Fielding (T) SDD C&TD Production LRIP SDD Prototypes Prototype Build BDENET MS B FRP MS C LRIP FCS S D D P ro to ty p es IOTE SD LRIP OCSW
A low-power, radiation-resistant, Silicon-Drift-Detector array for extraterrestrial element mapping
NASA Astrophysics Data System (ADS)
Ramsey, B. D.; Gaskin, J. A.; Elsner, R. F.; Chen, W.; Carini, G. A.; De Geronimo, G.; Keister, J.; Li, S.; Li, Z.; Siddons, D. P.; Smith, G.
2012-02-01
We are developing a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) for measuring the abundances of light surface elements (C to Fe) fluoresced by ambient radiation on remote airless bodies. The value of fluorescence spectrometry for surface element mapping is demonstrated by its inclusion on three recent lunar missions and by exciting new data that have recently been announced from the Messenger Mission to Mercury. The SDD-XRS instrument that we have been developing offers excellent energy resolution and an order of magnitude lower power requirement than conventional CCDs, making much higher sensitivities possible with modest spacecraft resources. In addition, it is significantly more radiation resistant than x-ray CCDs and therefore will not be subject to the degradation that befell recent lunar instruments. In fact, the intrinsic radiation resistance of the SDD makes it applicable even to the harsh environment of the Jovian system where it can be used to map the light surface elements of Europa. In this paper, we first discuss our element-mapping science-measurement goals. We then derive the necessary instrument requirements to meet these goals and discuss our current instrument development status with respect to these requirements.
Conversion electron spectrometry of Pu isotopes with a silicon drift detector.
Pommé, S; Paepen, J; Peräjärvi, K; Turunen, J; Pöllänen, R
2016-03-01
An electron spectrometry set-up was built at IRMM consisting of a vacuum chamber with a moveable source holder and windowless Peltier-cooled silicon drift detector (SDD). The SDD is well suited for measuring low-energy x rays and electrons emitted from thin radioactive sources with low self-absorption. The attainable energy resolution is better than 0.5keV for electrons of 30keV. It has been used to measure the conversion electron spectra of three plutonium isotopes, i.e. (238)Pu, (239)Pu, (240)Pu, as well as (241)Am (being a decay product of (241)Pu). The obtained mixed x-ray and electron spectra are compared with spectra obtained with a close-geometry set-up using another SDD in STUK and spectra measured with a Si(Li) detector at IRMM. The potential of conversion electron spectrometry for isotopic analysis of mixed plutonium samples is investigated. With respect to the (240)Pu/(239)Pu isotopic ratio, the conversion electron peaks of both isotopes are more clearly separated than their largely overlapping peaks in alpha spectra. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Hubert, S.; Boubault, F.
2018-03-01
In this article, we present the first X-ray calibration performed over the 0.1-1.5 keV spectral range by means of a soft X-ray Manson source and the monochromator SYMPAX. This monochromator, based on a classical Rowland geometry, presents the novelty to be able to board simultaneously two detectors and move them under vacuum in front of the exit slit of the monochromatizing stage. This provides the great advantage to perform radiometric measurements of the monochromatic X-ray photon flux with one reference detector while calibrating another X-ray detector. To achieve this, at least one secondary standard must be operated with SYMPAX. This paper presents thereby an efficiency transfer experiment between a secondary standard silicon drift detector (SDD), previously calibrated on BESSY II synchrotron Facility, and another one ("unknown" SDD), devoted to be used permanently with SYMPAX. The associated calibration process is described as well as corresponding results. Comparison with calibrated measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) Radiometric Laboratory shows a very good agreement between the secondary standard and the unknown SDD.
A Low-Power, Radiation-Resistant, Silicon-Drift-Detector Array for Extraterrestrial Element Mapping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramsey B. D.; De Geronimo G.; Gaskin, J.A.
2012-02-08
We are developing a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) for measuring the abundances of light surface elements (C to Fe) fluoresced by ambient radiation on remote airless bodies. The value of fluorescence spectrometry for surface element mapping is demonstrated by its inclusion on three recent lunar missions and by exciting new data that have recently been announced from the Messenger Mission to Mercury. The SDD-XRS instrument that we have been developing offers excellent energy resolution and an order of magnitude lower power requirement than conventional CCDs, making much higher sensitivities possible with modest spacecraft resources. In addition,more » it is significantly more radiation resistant than x-ray CCDs and therefore will not be subject to the degradation that befell recent lunar instruments. In fact, the intrinsic radiation resistance of the SDD makes it applicable even to the harsh environment of the Jovian system where it can be used to map the light surface elements of Europa. In this paper, we first discuss our element-mapping science-measurement goals. We then derive the necessary instrument requirements to meet these goals and discuss our current instrument development status with respect to these requirements.« less
de Moraes, Camila; Davel, Ana Paula Couto; Rossoni, Luciana Venturini; Antunes, Edson; Zanesco, Angelina
2008-05-29
Obesity has been associated with a variety of disease such as type II diabetes mellitus, arterial hypertension and atherosclerosis. Evidences have shown that exercise training promotes beneficial effects on these disorders, but the underlying mechanisms are not fully understood. The aim of this study was to investigate whether physical preconditioning prevents the deleterious effect of high caloric diet in vascular reactivity of rat aortic and mesenteric rings. Male Wistar rats were divided into sedentary (SD); trained (TR); sedentary diet (SDD) and trained diet (TRD) groups. Run training (RT) was performed in sessions of 60 min, 5 days/week for 12 weeks (70-80% VO2max). Triglycerides, glucose, insulin and nitrite/nitrate concentrations (NOx-) were measured. Concentration-response curves to acetylcholine (ACh) and sodium nitroprusside (SNP) were obtained. Expression of Cu/Zn superoxide dismutase (SOD-1) was assessed by Western blotting. High caloric diet increased triglycerides concentration (SDD: 216 +/- 25 mg/dl) and exercise training restored to the baseline value (TRD: 89 +/- 9 mg/dl). Physical preconditioning significantly reduced insulin levels in both groups (TR: 0.54 +/- 0.1 and TRD: 1.24 +/- 0.3 ng/ml) as compared to sedentary animals (SD: 0.87 +/- 0.1 and SDD: 2.57 +/- 0.3 ng/ml). On the other hand, glucose concentration was slightly increased by high caloric diet, and RT did not modify this parameter (SD: 126 +/- 6; TR: 140 +/- 8; SDD: 156 +/- 8 and TRD 153 +/- 9 mg/dl). Neither high caloric diet nor RT modified NOx- levels (SD: 27 +/- 4; TR: 28 +/- 6; SDD: 27 +/- 3 and TRD: 30 +/- 2 microM). Functional assays showed that high caloric diet impaired the relaxing response to ACh in mesenteric (about 13%), but not in aortic rings. RT improved the relaxing responses to ACh either in aortic (28%, for TR and 16%, to TRD groups) or mesenteric rings (10%, for TR and 17%, to TRD groups) that was accompanied by up-regulation of SOD-1 expression and reduction in triglycerides levels. The improvement in endothelial function by physical preconditioning in mesenteric and aortic arteries from high caloric fed-rats was directly related to an increase in NO bioavailability to the smooth muscle mostly due to SOD-1 up regulation.
He, Xiaoyuan; Zhao, Mingfeng; Chen, Jinyan; Wu, Rimao; Zhang, Jianlei; Cui, Rui; Jiang, Yanyu; Chen, Jie; Cao, Xiaoli; Xing, Yi; Zhang, Yuchen; Meng, Juanxia; Deng, Qi; Sui, Tao
2015-01-01
Objective To study the main molecular mechanisms responsible for itraconazole resistance in clinical isolates of Candida krusei. Methods The 14α-demethylases encoded by ERG11 gene in the 16 C.krusei clinical isolates were amplified by polymerase chain reaction (PCR), and their nucleotide sequences were determined to detect point mutations. Meanwhile, ERG11 and efflux transporters (ABC1 and ABC2) genes were determined by quantitative real-time reverse transcription polymerase chain reaction (qRT-PCR) for their expression in itraconazole-resistant (R), itraconazole-susceptible dose dependent (SDD) and itraconazole-susceptible (S) C.krusei at the mRNA level. Results We found 7-point mutations in ERG11 gene of all the C.krusei clinical isolates, including 6 synonymous mutations and 1 missense mutation (C44T). However, the missense mutation was found in the three groups. The mRNA levels of ERG11 gene in itraconazole-resistant isolates showed higher expression compared with itraconazole-susceptible dose dependent and itraconazole-susceptible ones (P = 0.015 and P = 0.002 respectively). ABC2 gene mRNA levels in itraconazole-resistant group was significantly higher than the other two groups, and the levels of their expression in the isolates appeared to increase with the decrease of susceptibility to itraconazole (P = 0.007 in SDD compared with S, P = 0.016 in SDD with R, and P<0.001 in S with R respectively). While ABC1 gene presented lower expression in itraconazole resistant strains. However, the mRNA levels of ERG11, ABC1 and ABC2 in a C.krusei (CK10) resistant to both itraconazole and voriconazole were expressed highest in all the itraconazole-resistant isolates. Conclusions There are ERG11 gene polymorphisms in clinical isolates of C.krusei. ERG11 gene mutations may not be involved in the development of itraconazole resistance in C.krusei. ERG11 and ABC2 overexpression might be responsible for the acquired itraconazole resistance of these clinical isolates. PMID:26308936
Novel Drift Structures for Silicon and Compound Semiconductor X-Ray and Gamma-Ray Detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradley E. Patt; Jan S. Iwanczyk
Recently developed silicon- and compound-semiconductor-based drift detector structures have produced excellent performance for charged particles, X rays, and gamma rays and for low-signal visible light detection. The silicon drift detector (SDD) structures that we discuss relate to direct X-ray detectors and scintillation photon detectors coupled with scintillators for gamma rays. Recent designs include several novel features that ensure very low dark current (both bulk silicon dark current and surface dark current) and hence low noise. In addition, application of thin window technology ensures a very high quantum efficiency entrance window on the drift photodetector.
Smits-Engelsman, Bouwien C M; Niemeijer, Anuschka S; van Waelvelde, Hilde
2011-01-01
Formal testing of 3 year old children is a new feature in the revised version of the Movement Assessment Battery for Children (Movement ABC-2). Our study evaluated the reliability and explored the clinical applicability of the Movement ABC-2 Test in this young age group. A total of 50 typically children were given two trials of the test within a one to two week interval by two physical therapists: same assessor (n=28 children) and different assessors (n=22 children). Psychometric properties were evaluated by calculating internal consistency (Cronbach α), intra-class correlation (ICC), the standard error of measurement (SEM), the smallest detectable difference (SDD) and Kappa values for classification agreement. The results are promising for future implementation of the Movement ABC-2 in clinical practice. The children's performance was highly reproducible when tested by the same assessor (ICC .94) The SEM was 1.7 or 2.1 standard scores for 90% or 95% confidence intervals respectively, making the test sensitive enough to detect individual changes. If two different assessors tested the children the ICC was .76. In conclusion, the revised test can be applied to assess motor performance in typically developing 3-year old children. Future studies are needed to confirm if the same can be said for children with motor delays. Copyright © 2011 Elsevier Ltd. All rights reserved.
OARSI-OMERACT definition of relevant radiological progression in hip/knee osteoarthritis.
Ornetti, P; Brandt, K; Hellio-Le Graverand, M-P; Hochberg, M; Hunter, D J; Kloppenburg, M; Lane, N; Maillefert, J-F; Mazzuca, S A; Spector, T; Utard-Wlerick, G; Vignon, E; Dougados, M
2009-07-01
Joint space width (JSW) evaluated in millimeters on plain X-rays is the currently optimal recognized technique to evaluate osteoarthritis (OA) structural progression. Data obtained can be presented at the group level (e.g., mean+/-standard deviation of the changes). Such presentation makes difficult the interpretation of the clinical relevance of the reported results. Therefore, a presentation at the individual level (e.g., % progressors) seems more attractive but requires to determining a cut-off. Several methodologies have been proposed to define cut-offs in JSW: arbitrary chosen cut-off, cut-off based on the validity to predict a relevant end-point such as the requirement of total articular replacement or cut-off based on the measurement error such as smallest detectable difference (SDD). The objective of this OARSI-OMERACT initiative was to define a cut-off evaluated in millimeters on plain X-rays above which a change in JSW could be considered as relevant in patients with hip and knee OA. The first step consisted in a systematic literature research performed using Medline database up to July 2007 to obtain all manuscripts published between 1990 and 2007 reporting a cut-off value in JSW evaluated in millimeters at either the knee or hip level. The second step consisted in a consensus based on the best knowledge of the 11 experts with the support of the available evidence. Among the 506 articles selected by the search, 47 articles reported cut-off of JSW in millimeters. There was a broad heterogeneity in cut-off values, whatever the methodologies or the OA localization considered (e.g., from 0.12 to 0.84 mm and from 0.22 to 0.78 mm for Knee (seven studies) and hip (seven studies), respectively when considering the data obtained based on the reliability). Based on the data extracted in the literature, the expert committee proposed a definition of relevant change in JSW based on plain X-rays, on an absolute change of JSW in millimeters and on the measurement error e.g., calculation of the SDD using the Bland and Altman technique. The results of the analysis of JSW should be expressed in terms of a dichotomous variable (e.g., progressors yes/no): a patient with a change in JSW during the study over such SDD will fulfill the definition of "progressor". Moreover, the pilot study aimed at evaluating the measurement error should be designed to reflect the different characteristics of the primary study in which the analysis of the radiological findings will be based on (patient's characteristics, centers characteristics, readers). This initiative based on both an Evidence Based Medicine (Systematic Literature Research) and Expert Opinion approach resulted in a proposal of definition of relevant radiological progression in OA to be used as end-point in clinical trials and also recommendations on the conduct of the reliability study allowing such definition.
Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors
NASA Astrophysics Data System (ADS)
Campana, R.; Evangelista, Y.; Fuschino, F.; Ahangarianabhari, M.; Macera, D.; Bertuccio, G.; Grassi, M.; Labanti, C.; Marisaldi, M.; Malcovati, P.; Rachevski, A.; Zampa, G.; Zampa, N.; Andreani, L.; Baldazzi, G.; Del Monte, E.; Favre, Y.; Feroci, M.; Muleri, F.; Rashevskaya, I.; Vacchi, A.; Ficorella, F.; Giacomini, G.; Picciotto, A.; Zuffa, M.
2014-08-01
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end electronics for XDXL-2, a large-area (30.5 cm2) SDD prototype. The ASICs were integrated on a specifically developed PCB hosting also the detector. Results on the ASIC noise performances, both stand-alone and bonded to the large area SDD, are presented and discussed.
Novel drift structures for silicon and compound semiconductor X-ray and gamma-ray detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patt, B.E.; Iwanczyk, J.S.
Recently developed silicon- and compound-semiconductor-based drift detector structures have produced excellent performance for charged particles, X-rays, and gamma rays and for low-signal visible light detection. The silicon drift detector (SDD) structures that the authors discuss relate to direct X-ray detectors and scintillation photon detectors coupled with scintillators for gamma rays. Recent designs include several novel features that ensure very low dark current and hence low noise. In addition, application of thin window technology ensures a very high quantum efficiency entrance window on the drift photodetector. The main features of the silicon drift structures for X rays and light detection aremore » very small anode capacitance independent of the overall detector size, low noise, and high throughput. To take advantage of the small detector capacitance, the first stage of the electronics needs to be integrated into the detector anode. In the gamma-ray application, factors other than electronic noise dominate, and there is no need to integrate the electronics into the anode. Thus, a different drift structure is needed in conjunction with a high-Z material. The main features in this case are large active detector volume and electron-only induced signal.« less
Zhang, Yunlin; Liu, Xiaohan; Qin, Boqiang; Shi, Kun; Deng, Jianming; Zhou, Yongqiang
2016-04-04
Terrestrial and aquatic ecosystem degradation is widely recognized as a major global environmental and development problem. Although great efforts have been made to prevent aquatic ecosystem degradation, the degree, extent and impacts of this phenomenon remain controversial and unclear, such as its driving mechanisms. Here, we present results from a 17-year field investigation (1998-2014) of water quality and a 12-year remote sensing mapping (2003-2014) of the aquatic vegetation presence frequency (VPF) in Eastern Lake Taihu, a macrophyte-dominated bay of Lake Taihu in China. In the past 17 years, nutrient concentrations and water level (WL) have significantly increased, but the Secchi disk depth (SDD) has significantly decreased. These changes were associated with increased lake eutrophication and a degraded underwater light climate that further inhibited the growth of aquatic vegetation. In Eastern Lake Taihu, increased nutrients, chlorophyll a and WL, and a decreased SDD were all significantly correlated with a decreased VPF. NH4(+)-N concentration and SDD/WL were the most important controlling factors for VPF. Therefore, increased anthropogenic nutrient inputs and a degraded underwater light climate surely result in a decreased VPF. These results elucidate the driving mechanism of aquatic vegetation degradation and will facilitate Lake Taihu ecological restoration.
NASA Astrophysics Data System (ADS)
Zhang, Yunlin; Liu, Xiaohan; Qin, Boqiang; Shi, Kun; Deng, Jianming; Zhou, Yongqiang
2016-04-01
Terrestrial and aquatic ecosystem degradation is widely recognized as a major global environmental and development problem. Although great efforts have been made to prevent aquatic ecosystem degradation, the degree, extent and impacts of this phenomenon remain controversial and unclear, such as its driving mechanisms. Here, we present results from a 17-year field investigation (1998-2014) of water quality and a 12-year remote sensing mapping (2003-2014) of the aquatic vegetation presence frequency (VPF) in Eastern Lake Taihu, a macrophyte-dominated bay of Lake Taihu in China. In the past 17 years, nutrient concentrations and water level (WL) have significantly increased, but the Secchi disk depth (SDD) has significantly decreased. These changes were associated with increased lake eutrophication and a degraded underwater light climate that further inhibited the growth of aquatic vegetation. In Eastern Lake Taihu, increased nutrients, chlorophyll a and WL, and a decreased SDD were all significantly correlated with a decreased VPF. NH4+-N concentration and SDD/WL were the most important controlling factors for VPF. Therefore, increased anthropogenic nutrient inputs and a degraded underwater light climate surely result in a decreased VPF. These results elucidate the driving mechanism of aquatic vegetation degradation and will facilitate Lake Taihu ecological restoration.
A neutron spectrometer based on temperature variations in superheated drop compositions
NASA Astrophysics Data System (ADS)
Apfel, Robert E.; d'Errico, Francesco
2002-01-01
The response of superheated drop detectors (SDDs) to neutron radiation varies in a self-consistent manner with variations in temperature and pressure, making such compositions suitable for neutron spectrometry. The advantage of this approach is that the response functions of candidate materials versus energy as the temperature or pressure is varied are nested and have distinct thresholds, with no thermal neutron response. These characteristics permit unfolding without the uncertainties associated with other spectrometry techniques, where multiple solutions are possible, thus requiring an initial guess of the spectrum. A spectrometer was developed based on the well-established technology for acoustic sensing of bubble events interfaced with a proportional-integral-derivative temperature controller. The active monitor for neutrons, called REMbrandt™, was used as the platform for controlling temperature on a SDD probe and for data acquisition, thereby automating the process of measuring the neutron energy spectrum. The new instrument, called REM-SPEC™, implements and automates the original BINS approach: it adjusts the temperature of the SDD vial in increasing steps and measures the bubble event rate at each step. By using two distinct SDD materials with overlapping responses, the 0.1-20 MeV range of energies relevant to practical spectrometry is readily covered. Initial experiments with an Am-Be source validate the operational protocols of this device.
Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization
NASA Technical Reports Server (NTRS)
Casper, Stephanie; Williams, Nicole M. M.
2010-01-01
The purpose of this test is to evaluate the odor containment of the urine containment bag (UCB), P/N SDD46107234-306 in an environment simulating a spacecraft capsule. The goal is to determine the time of odor break through and the acceptability of the odor, once break through occurs. The goal is to simulate, as close as possible, the volume ratio (trash to free volume), trash content (vomit, urine, feces, and food trash), humidity and temperature of the capsule. The goal for minimum break through is 48 hours (Orion Block 0) from the start of the test. The goal for acceptability of odor is 2 weeks (including docked ISS time for Orion Block 0). Two UCB's will be tested simultaneously in different chambers. The one UCB will be tested empty, serving as a control. Odor break through will be based upon the when the filled UCB total organics exceeds that of the control (empty UCB) by a level detectable by a human panel (approximately 2 ppm).
NASA Technical Reports Server (NTRS)
Knupp, Kevin R.; Coleman, Timothy; Carey, Larry; Peterson, Walt; Elkins, Calvin
2008-01-01
During the Super Tuesday Tornado Outbreak on 5-6 February, a significant number of storms passed within about 40 km of WSR-88D radars. This distance, combined with the significant motion vector (from the southwest at 20-25 m per second) of relatively steady storms, is amenable to a synthetic dual Doppler analysis during the times when the storms passed the WSR-88D locations. Nine storms will be analyzed using the SDD technique. The following table provides their general characteristics and nearest approach to the 88D radars. For this data set, storm structure ranges from isolated supercell to QLCS. Each storm will be analyzed for a 40-60 min period during passage by the WSR-88D radar to determine general storm properties. Analysis of high-resolution single Doppler data around the time of passage (plus or minus 30 min), combined with 1-2 SDD analyses, will be used to examine the kinematic structure of low-level circulations (e.g., mesocyclone, downdraft) and the relation to the parent storm. This analysis may provide insights on the fundamental differences between cyclonic circulations in supercell storms and those within QCLS's.
Wang, Wei-Wei; Dang, Jing-Shuang; Zhao, Xiang; Nagase, Shigeru
2017-11-09
We introduce a mechanistic study based on a controversial fullerene bottom-up growth model proposed by R. Saito, G. Dresselhaus, and M. S. Dresselhaus. The so-called SDD C 2 addition model has been dismissed as chemically inadmissible but here we prove that it is feasible via successive atomic-carbon-participated addition and migration reactions. Kinetic calculations on the formation of isolated pentagon rule (IPR)-obeying C 70 and Y 3 N@C 80 are carried out by employing the SDD model for the first time. A stepwise mechanism is proposed with a considerably low barrier of ca. 2 eV which is about 3 eV lower than a conventional isomerization-containing fullerene growth pathway.
Knols, Ruud H; Aufdemkampe, Geert; de Bruin, Eling D; Uebelhart, Daniel; Aaronson, Neil K
2009-01-01
Background Hand-held dynamometry is a portable and inexpensive method to quantify muscle strength. To determine if muscle strength has changed, an examiner must know what part of the difference between a patient's pre-treatment and post-treatment measurements is attributable to real change, and what part is due to measurement error. This study aimed to determine the relative and absolute reliability of intra and inter-observer strength measurements with a hand-held dynamometer (HHD). Methods Two observers performed maximum voluntary peak torque measurements (MVPT) for isometric knee extension in 24 patients with haematological malignancies. For each patient, the measurements were carried out on the same day. The main outcome measures were the intraclass correlation coefficient (ICC ± 95%CI), the standard error of measurement (SEM), the smallest detectable difference (SDD), the relative values as % of the grand mean of the SEM and SDD, and the limits of agreement for the intra- and inter-observer '3 repetition average' and the 'highest value of 3 MVPT' knee extension strength measures. Results The intra-observer ICCs were 0.94 for the average of 3 MVPT (95%CI: 0.86–0.97) and 0.86 for the highest value of 3 MVPT (95%CI: 0.71–0.94). The ICCs for the inter-observer measurements were 0.89 for the average of 3 MVPT (95%CI: 0.75–0.95) and 0.77 for the highest value of 3 MVPT (95%CI: 0.54–0.90). The SEMs for the intra-observer measurements were 6.22 Nm (3.98% of the grand mean (GM) and 9.83 Nm (5.88% of GM). For the inter-observer measurements, the SEMs were 9.65 Nm (6.65% of GM) and 11.41 Nm (6.73% of GM). The SDDs for the generated parameters varied from 17.23 Nm (11.04% of GM) to 27.26 Nm (17.09% of GM) for intra-observer measurements, and 26.76 Nm (16.77% of GM) to 31.62 Nm (18.66% of GM) for inter-observer measurements, with similar results for the limits of agreement. Conclusion The results indicate that there is acceptable relative reliability for evaluating knee strength with a HHD, while the measurement error observed was modest. The HHD may be useful in detecting changes in knee extension strength at the individual patient level. PMID:19272149
NASA Astrophysics Data System (ADS)
Fu, Xiao-Hui; Li, Chun-Lai; Zhang, Guang-Liang; Zou, Yong-Liao; Liu, Jian-Jun; Ren, Xin; Tan, Xu; Zhang, Xiao-Xia; Zuo, Wei; Wen, Wei-Bin; Peng, Wen-Xi; Cui, Xing-Zhu; Zhang, Cheng-Mo; Wang, Huan-Yu
2014-12-01
The Active Particle-induced X-ray Spectrometer (APXS) is an important payload mounted on the Yutu rover, which is part of the Chang'e-3 mission. The scientific objective of APXS is to perform in-situ analysis of the chemical composition of lunar soil and rock samples. The radioactive sources, 55Fe and 109Cd, decay and produce α-particles and X-rays. When X-rays and α-particles interact with atoms in the surface material, they knock electrons out of their orbits, which release energy by emitting X-rays that can be measured by a silicon drift detector (SDD). The elements and their concentrations can be determined by analyzing their peak energies and intensities. APXS has analyzed both the calibration target and lunar soil once during the first lunar day and again during the second lunar day. The total detection time lasted about 266 min and more than 2000 frames of data records have been acquired. APXS has three operating modes: calibration mode, distance sensing mode and detection mode. In detection mode, work distance can be calculated from the X-ray counting rate collected by SDD. Correction for the effect of temperature has been performed to convert the channel number for each spectrum to X-ray energy. Dead time correction is used to eliminate the systematic error in quantifying the activity of an X-ray pulse in a sample and derive the real count rate. We report APXS data and initial results during the first and second lunar days for the Yutu rover. In this study, we analyze the data from the calibration target and lunar soil on the first lunar day. Seven major elements, including Mg, Al, Si, K, Ca, Ti and Fe, have been identified. Comparing the peak areas and ratios of calibration basalt and lunar soil the landing site was found to be depleted in K, and have lower Mg and Al but higher Ca, Ti, and Fe. In the future, we will obtain the elemental concentrations of lunar soil at the Chang'e-3 landing site using APXS data.
The SIRIUS mixed analog-digital ASIC developed for the LOFT LAD and WFM instruments
NASA Astrophysics Data System (ADS)
Cros, A.; Rambaud, D.; Moutaye, E.; Ravera, L.; Barret, D.; Caïs, P.; Clédassou, R.; Bodin, P.; Seyler, J. Y.; Bonzo, A.; Feroci, M.; Labanti, C.; Evangelista, Y.; Favre, Y.
2014-07-01
We report on the development and characterization of the low-noise, low power, mixed analog-digital SIRIUS ASICs for both the LAD and WFM X-ray instruments of LOFT. The ASICs we developed are reading out large area silicon drift detectors (SDD). Stringent requirements in terms of noise (ENC of 17 e- to achieve an energy resolution on the LAD of 200 eV FWHM at 6 keV) and power consumption (650 μW per channel) were basis for the ASICs design. These SIRIUS ASICs are developed to match SDD detectors characteristics: 16 channels ASICs adapted for the LAD (970 microns pitch) and 64 channels for the WFM (145 microns pitch) will be fabricated. The ASICs were developed with the 180nm mixed technology of TSMC.
Low-noise analog readout channel for SDD in X-ray spectrometry
NASA Astrophysics Data System (ADS)
Atkin, E.; Gusev, A.; Krivchenko, A.; Levin, V.; Malankin, E.; Normanov, D.; Rotin, A.; Sagdiev, I.; Samsonov, V.
2016-01-01
A low-noise analog readout channel optimized for operation with the Silicon Drift Detectors (SDDs) with built-in JFET is presented. The Charge Sensitive Amplifier (CSA) operates in a pulse reset mode using the reset diode built-in the SDD detector. The shaper is a 6th order semi-Gaussian filter with switchable discrete shaping times. The readout channel provides the Equivalent Noise Charge (ENC) of 12e- (simulation) and input dynamic range of 30 keV . The measured energy resolution at the 5,89 keV line of a 55Fe X-ray source is 336 eV (FWHM). The channel was prototyped via Europractice in the AMS 350 nm process as miniASIC. The simulation and first measurement results are presented in the paper.
Pfaller, Michael A; Diekema, Daniel J; Procop, Gary W; Rinaldi, Michael G
2013-09-01
A commercially available, fully automated yeast susceptibility test system (Vitek 2; bioMérieux, Marcy d'Etoile, France) was compared in 3 different laboratories with the Clinical and Laboratory Standards Institute (CLSI) reference microdilution (BMD) method by testing 2 quality control strains, 10 reproducibility strains, and 425 isolates of Candida spp. against fluconazole and voriconazole. Reference CLSI BMD MIC endpoints and Vitek 2 MIC endpoints were read after 24 hours and 9.1-27.1 hours incubation, respectively. Excellent essential agreement (within 2 dilutions) between the reference and Vitek 2 MICs was observed for fluconazole (97.9%) and voriconazole (96.7%). Categorical agreement (CA) between the 2 methods was assessed using the new species-specific clinical breakpoints (CBPs): susceptible (S) ≤2 μg/mL, susceptible dose-dependent (SDD) 4 μg/mL, and resistant (R) ≥8 μg/mL for fluconazole and Candida albicans, Candida tropicalis, and Candida parapsilosis and ≤32 μg/mL (SDD), ≥64 μg/mL (R) for Candida glabrata; S ≤0.12 μg/mL, SDD 0.25-0.5 μg/mL, R ≥1 μg/mL for voriconazole and C. albicans, C. tropicalis, and C. parapsilosis, and ≤0.5 μg/mL (S), 1 μg/mL (SDD), ≥2 μg/mL (R) for Candida krusei. The epidemiological cutoff value (ECV) of 0.5 μg/mL for voriconazole and C. glabrata was used to differentiate wild-type (WT; MIC ≤ ECV) from non-WT (MIC > ECV) strains of this species. Due to the lack of CBPs for the less common species, the ECVs for fluconazole and voriconazole, respectively, were used for Candida lusitaniae (2 μg/mL and 0.03 μg/mL), Candida dubliniensis (0.5 μg/mL and 0.03 μg/mL), Candida guilliermondii (8 μg/mL and 0.25 μg/mL), and Candida pelliculosa (4 μg/mL and 0.25 μg/mL) to categorize isolates of these species as WT and non-WT. CA between the 2 methods was 96.8% for fluconazole and 96.5% for voriconazole with less than 1% very major errors and 1.3-3.0% major errors. The Vitek 2 yeast susceptibility system remains comparable to the CLSI BMD reference method for testing the susceptibility of Candida spp. when using the new (lower) CBPs and ECVs. © 2013.
Yu, Hao; Chen, Chuan; Ma, Jincai; Liu, Wenzong; Zhou, Jizhong; Lee, Duu-Jong; Ren, Nanqi; Wang, Aijie
2014-07-01
The elemental sulfur (S°) recovery was evaluated in the presence of nitrate in two development models of simultaneous desulfurization and denitrification (SDD) process. At the loading rates of 0.9 kg S/(m³·day) for sulfide and 0.4 kg N/(m³·day) for nitrate, S° conversion rate was 91.1% in denitrifying sulfide removal (DSR) model which was higher than in integrated simultaneous desulfurization and denitrification (ISDD) model (25.6%). A comprehensive analysis of functional diversity, structure and metabolic potential of microbial communities was examined in two models by using functional gene array (GeoChip 2.0). GeoChip data indicated that diversity indices, community structure, and abundance of functional genes were distinct between two models. Diversity indices (Simpson's diversity index (1/D) and Shannon-Weaver index (H')) of all detected genes showed that with elevated influent loading rate, the functional diversity decreased in ISDD model but increased in DSR model. In contrast to ISDD model, the overall abundance of dsr genes was lower in DSR model, while some functional genes targeting from nitrate-reducing sulfide-oxidizing bacteria (NR-SOB), such as Thiobacillus denitrificans, Sulfurimonas denitrificans, and Paracoccus pantotrophus were more abundant in DSR model which were highly associated with the change of S(0) conversion rate obtained in two models. The results obtained in this study provide additional insights into the microbial metabolic mechanisms involved in ISDD and DSR models, which in turn will improve the overall performance of SDD process. Copyright © 2014. Published by Elsevier B.V.
Holick's rule and vitamin D from sunlight.
Dowdy, John C; Sayre, Robert M; Holick, Michael F
2010-07-01
Holick's rule says that sun exposure 1/4 of a minimal erythemal dose (MED) over 1/4 of a body is equivalent to 1000 International Units (IU) oral vitamin D3. Webb and Engelsen recently commented that the ultraviolet (UV) spectrum used to establish Holick's rule is unknown. They consequently used a spring midday Boston solar spectrum to estimate ample sunlight exposures for previtamin D3 (preD3) at various locations. Literature review found the source upon which this rule is based was a fluorescent sunlamp (FS lamp). The FS spectrum is known and its relative weighting against the action spectra for erythema and the preD3 is significantly different from the solar spectrum used to derive the standard vitamin D effective dose (SDD). The preD3 effectiveness of the solar spectrum per unit erythemal hazard is greater than the FS lamp by a factor of 1.32. Consequently, UV exposure estimates based on Boston reference sunlight, instead of the UV lamp employed in the originating experiments, over estimate UV exposure equivalent to approximately 1000 IU orally by approximately 1/3. This redefinition of SDD impacts risk/benefit assessments of optimal/feasible sun exposure for vitamin D maintenance and the application of Holick's rule to rational public health messages. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
O'Brien, Travis J; Ding, Hao; Suh, Mina; Thompson, Chad M; Parsons, Barbara L; Harris, Mark A; Winkelman, William A; Wolf, Jeffrey C; Hixon, J Gregory; Schwartz, Arnold M; Myers, Meagan B; Haws, Laurie C; Proctor, Deborah M
2013-06-14
Chronic exposure to high concentrations of hexavalent chromium [Cr(VI)] as sodium dichromate dihydrate (SDD) in drinking water induces duodenal tumors in mice, but the mode of action (MOA) for these tumors has been a subject of scientific debate. To evaluate the tumor-site-specific genotoxicity and cytotoxicity of SDD in the mouse small intestine, tissue pathology and cytogenetic damage were evaluated in duodenal crypt and villus enterocytes from B6C3F1 mice exposed to 0.3-520mg/L SDD in drinking water for 7 and 90 days. Allele-competitive blocker PCR (ACB-PCR) was used to investigate the induction of a sensitive, tumor-relevant mutation, specifically in vivo K-Ras codon 12 GAT mutation, in scraped duodenal epithelium following 90 days of drinking water exposure. Cytotoxicity was evident in the villus as disruption of cellular arrangement, desquamation, nuclear atypia and blunting. Following 90 days of treatment, aberrant nuclei, occurring primarily at villi tips, were significantly increased at ≥60mg/L SDD. However, in the crypt compartment, there were no dose-related effects on mitotic and apoptotic indices or the formation of aberrant nuclei indicating that Cr(VI)-induced cytotoxicity was limited to the villi. Cr(VI) caused a dose-dependent proliferative response in the duodenal crypt as evidenced by an increase in crypt area and increased number of crypt enterocytes. Spontaneous K-Ras codon 12 GAT mutations in untreated mice were higher than expected, in the range of 10(-2) to 10(-3); however no treatment-related trend in the K-Ras codon 12 GAT mutation was observed. The high spontaneous background K-Ras mutant frequency and Cr(VI) dose-related increases in crypt enterocyte proliferation, without dose-related increase in K-Ras mutant frequency, micronuclei formation, or change in mitotic or apoptotic indices, are consistent with a lack of genotoxicity in the crypt compartment, and a MOA involving accumulation of mutations late in carcinogenesis as a consequence of sustained regenerative proliferation. Published by Elsevier B.V.
González-Vega, J Caroline; Walk, Carrie L; Liu, Yanhong; Stein, Hans H
2014-01-01
An experiment was conducted to test the hypothesis that the standardised digestibility of Ca in calcium carbonate and Lithothamnium calcareum Ca is not different regardless of the level of dietary Ca, and that phytic acid affects the digestibility of Ca in these two ingredients to the same degree. The objectives were to determine where in the intestinal tract Ca absorption takes place and if there are measurable quantities of basal endogenous Ca fluxes in the stomach, small intestine or large intestine. Diets contained calcium carbonate or L. calcareum Ca as the sole source of Ca, 0% or 1% phytic acid and 0.4% or 0.8% Ca. A Ca-free diet was also formulated and used to measure endogenous fluxes and losses of Ca. Nine growing pigs (initial body weight 23.8 ± 1.3 kg) were cannulated in the duodenum and in the distal ileum, and faecal, ileal and duodenal samples were collected. Duodenal endogenous fluxes of Ca were greater (p < 0.05) than ileal endogenous fluxes and total tract endogenous losses of Ca, but ileal endogenous fluxes were less (p < 0.05) than total tract endogenous losses. Standardised digestibility of Ca was not affected by the level of phytic acid, but decreased (p < 0.05) as Ca level increased in L. calcareum Ca diets, but that was not the case if calcium carbonate was the source of Ca (interaction, p < 0.05). The standardised duodenal digestibility (SDD), standardised ileal digestibility (SID) and standardised total tract digestibility (STTD) of Ca were not different if calcium carbonate was the source of dietary Ca. However, the STTD of Ca in L. calcareum Ca was greater (p < 0.05) than the SID and SDD of Ca. The SDD, SID and STTD of Ca in calcium carbonate were greater (p < 0.05) than those of L. calcareum Ca. In conclusion, under the conditions of this experiment, standardised digestibility of Ca is not affected by the level of phytic acid, but may be affected by dietary Ca level depending on the Ca source. Calcium from calcium carbonate is mostly absorbed before the duodenum, but Ca from L. calcareum Ca is mostly absorbed in the jejunum and ileum.
Cost savings of outpatient versus standard inpatient total knee arthroplasty
Huang, Adrian; Ryu, Jae-Jin; Dervin, Geoffrey
2017-01-01
Background With diminishing reimbursement rates and strained public payer budgets, a high-volume inpatient procedure, such as total knee arthroplasty (TKA), is a common target for improving cost efficiencies. Methods This prospective case–control study compared the cost-minimization of same day discharge (SDD) versus inpatient TKA. We examined if and where cost savings can be realized and the magnitude of savings that can be achieved without compromising quality of care. Outcome variables, including detailed case costs, return to hospital rates and complications, were documented and compared between the first 20 SDD cases and 20 matched inpatient controls. Results In every case–control match, the SDD TKA was less costly than the inpatient procedure and yielded a median cost savings of approximately 30%. The savings came primarily from costs associated with the inpatient encounter, such as surgical ward, pharmacy and patient meal costs. At 1 year, there were no major complications and no return to hospital or readmission encounters for either group. Conclusion Our results are consistent with previously published data on the cost savings associated with short stay or outpatient TKA. We have gone further by documenting where those savings were in a matched cohort design. Furthermore, we determined where cost savings could be realized during the patient encounter and to what degree. In carefully selected patients, outpatient TKA is a feasible alternative to traditional inpatient TKA and is significantly less costly. Furthermore, it was deemed to be safe in the perioperative period. PMID:28234591
Silicon Drift Detectors - A Novel Technology for Vertex Detectors
NASA Astrophysics Data System (ADS)
Lynn, D.
1996-10-01
Silicon Drift Detectors (SDD) are novel position sensing silicon detectors which operate in a manner analogous to gas drift detectors. Single SDD's were shown in the CERN NA45 experiment to permit excellent spatial resolution (< 10 μm), to handle large particle occupancy, and to require a small fraction of the number of electronic channels of an equivalent pixel detector. The Silicon Vertex Tracker (SVT) for the STAR experiment at RHIC is based on this new technology. The SVT will consist of 216 SDD's, each 6.3 cm by 6.3 cm, arranged in a three layer barrel design, covering 2 π in azimuth and ±1 in pseudo-rapidity. Over the last three years we undertook a concentrated R+D effort to optimize the performance of the detector by minimizing the inactive area, the operating voltage and the data volume. We will present test results from several wafer prototypes. The charge produced by the passage of ionizing particles through the bulk of the detectors is collected on segmented anodes, with a pitch of 250 μm, on the far edges of the detector. The anodes are wire-bonded to a thick film multi-chip module which contains preamplifier/shaper chips and CMOS based switched capacitor arrays used as an analog memory pipeline. The ADC is located off-detector. The complete readout chain from the wafer to the DAQ will be presented. Finally we will show physics performance simulations based on the resolution achieved by the SVT prototypes.
NASA Astrophysics Data System (ADS)
Johnstone, Christopher Daniel; Bazalova-Carter, Magdalena
2018-06-01
The goal of this work was to establish imaging dose to mouse organs with a validated Monte Carlo (MC) model of the image-guided Small Animal Radiation Research Platform (SARRP) and to investigate the effect of scatter from the internal walls on animal therapy dose determination. A MC model of the SARRP was built in the BEAMnrc code and validated with a series of homogeneous and heterogeneous phantom measurements. A segmented microCT scan of a mouse was used in DOSXYZnrc to determine mouse organ microCT imaging doses to 15–35 g mice for the SARRP pancake (mouse lying on couch) and standard (mouse standing on couch) imaging geometries for 40–80 kVp tube voltages. Imaging dose for off-center positioning shifts and maintaining image noise across tube voltages were also calculated. Half-value layer (HVL) measurements for the 220 kVp therapy beam in the presence of the SARRP shielding cabinet were modeled in BEAMnrc and compared to the 100 cm source-to-detector distance (SDD) in the scatter free, narrow-beam geometry recommended by the American Association of Physicists in Medicine Task Group 61 (AAPM TG-61). For a 60 kVp, 0.8 mA, and 60 s scan protocol, maximum mean organ imaging doses to boney and non-boney structures were 10.5 cGy and 3.5 cGy, respectively, for an average size 20 g mouse. Current-exposure combinations above 323, 203, 147, 116, and 95 mAs for 40–80 kVp tube voltages, respectively, will increase body doses above 10 cGy. MicroCT mean body dose was 18% lower in pancake compared to standard imaging geometry. An 11% difference in measured HVL at a 50 cm SDD was found compared to MC simulated HVL for the AAPM TG-61 recommended scatter free geometry at a 100 cm SDD. This change in HVL resulted in a 0.5% change in absorbed dose to water calculations for the treatment beam.
System design document for the INFLO prototype.
DOT National Transportation Integrated Search
2014-03-01
This report documents the high level System Design Document (SDD) for the prototype development and demonstration of the Intelligent Network Flow Optimization (INFLO) application bundle, with a focus on the Speed Harmonization (SPD-HARM) and Queue Wa...
NASA Astrophysics Data System (ADS)
Imtiaz, Waqas A.; Ilyas, M.; Khan, Yousaf
2016-11-01
This paper propose a new code to optimize the performance of spectral amplitude coding-optical code division multiple access (SAC-OCDMA) system. The unique two-matrix structure of the proposed enhanced multi diagonal (EMD) code and effective correlation properties, between intended and interfering subscribers, significantly elevates the performance of SAC-OCDMA system by negating multiple access interference (MAI) and associated phase induce intensity noise (PIIN). Performance of SAC-OCDMA system based on the proposed code is thoroughly analyzed for two detection techniques through analytic and simulation analysis by referring to bit error rate (BER), signal to noise ratio (SNR) and eye patterns at the receiving end. It is shown that EMD code while using SDD technique provides high transmission capacity, reduces the receiver complexity, and provides better performance as compared to complementary subtraction detection (CSD) technique. Furthermore, analysis shows that, for a minimum acceptable BER of 10-9 , the proposed system supports 64 subscribers at data rates of up to 2 Gbps for both up-down link transmission.
A Review on Spectral Amplitude Coding Optical Code Division Multiple Access
NASA Astrophysics Data System (ADS)
Kaur, Navpreet; Goyal, Rakesh; Rani, Monika
2017-06-01
This manuscript deals with analysis of Spectral Amplitude Coding Optical Code Division Multiple Access (SACOCDMA) system. The major noise source in optical CDMA is co-channel interference from other users known as multiple access interference (MAI). The system performance in terms of bit error rate (BER) degrades as a result of increased MAI. It is perceived that number of users and type of codes used for optical system directly decide the performance of system. MAI can be restricted by efficient designing of optical codes and implementing them with unique architecture to accommodate more number of users. Hence, it is a necessity to design a technique like spectral direct detection (SDD) technique with modified double weight code, which can provide better cardinality and good correlation property.
NASA Astrophysics Data System (ADS)
Salge, T.; Goran, D.
2010-12-01
SDD systems have become state of the art technology in the field of EDS. The main characteristic of the SDDs is their extremely high pulse load capacity of up to 750,000 counts per second at good energy resolution (<123 eV Mn-Kα, <46 eV C-Kα at 100,000 counts per seconds). These properties in conjunction with electron backscatter diffraction (EBSD) technique and modern data processing allows not only high speed mapping but also hyperspectral analysis. Here, a database is created that contains an EDS spectrum and/or EBSD pattern for each pixel of the SEM image setting the stage for innovative analysis options: The Maximum Pixel Spectrum function [1] synthesizes a spectrum out of the EDS database, consisting of the highest count level found in each spectrum channel. Here, (trace) elements which occur in only one pixel can be detected qualitatively. Areas of similar EDS composition can be made visible with Autophase, a spectroscopic phase detection system. In cases where the crystallographic phase assessment by EBSD is problematic due to pattern similarity, the EDS signal can be used as additional information for phase separation. This paper presents geoscience applications with the QUANTAX system with EDS SDD and EBSD detector using the options described above: (1) Drill core analysis of a Chicxulub impact ejecta sequence from the K/Pg boundary at ODP leg 207 [2] using fast, high resolution element maps. (2) Detection of monazite in granite by the Maximum Pixel Spectrum function. (3) Distribution of elements with overlapping peaks by deconvolution at the example of rare earth elements in zoned monazite. (4) Spectroscopic phase analysis of a sulfate-carbonate-dominated impact matrix at borehole UNAM-7 from the Chicxulub impact crater [3]. (5) EBSD studies with examples of iron meteorites and impact-induced, recrystallized carbonate melts [4]. In addition, continuing technological advances require the elemental analysis of increasingly smaller structures in many fields, including geosciences. It will be demonstrated that using low accelerating voltages, the element distribution of structures at the nanoscale in bulk samples can be displayed in a short time due to optimized signal processing and solid angle. Peaks composed of contributions from several overlapping elements e.g. N-K (392 eV) and Ti-Ll (395 eV) can be deconvolved [6] using an improved atomic database with 250 additional L, M and N lines below 4 keV. Improved light element quantification allows the standardless quantification of features at the nanoscale such as rutile grains 200-500 nm in size. References: [1] Bright D S. & Newbury D. E. (2004) Journal of Microscopy 216:186-193. [2] Schulte P. et al. (2010) Science 327: 1214-1218. [3] Salge T. (2007) PhD thesis: 130p. http://edoc.huberlin.de/docviews/abstract.php?lang=ger&id=27753. [4] Deutsch A. et al. MAPS 45: A45. [6] Tunckan O. (2010) Joining ceramics using capacitor discharge technique and determination of metal ceramic interface reactions, PhD thesis, Anadolu University, Eskisehir, Turkey. Acknowledgements: We thank P. Schulte, A. Deutsch, ODP, L. Hecht, A. Kearsley, J. Urrutria-Fucugauchi, O. Tunckan and S. Turan for generously providing the samples.
Flynn, Oliver J.; Cukras, Catherine A.; Jeffrey, Brett G.
2018-01-01
Purpose To examine spatial changes in rod-mediated function in relationship to local structural changes across the central retina in eyes with a spectrum of age-related macular degeneration (AMD) disease severity. Methods Participants were categorized into five AMD severity groups based on fundus features. Scotopic thresholds were measured at 14 loci spanning ±18° along the vertical meridian from one eye of each of 42 participants (mean = 71.7 ± 9.9 years). Following a 30% bleach, dark adaptation was measured at eight loci (±12°). Rod intercept time (RIT) was defined from the time to detect a −3.1 log cd/m2 stimulus. RITslope was defined from the linear fit of RIT with decreasing retinal eccentricity. The presence of subretinal drusenoid deposits (SDD), ellipsoid (EZ) band disruption, and drusen at the test loci was evaluated using optical coherence tomography. Results Scotopic thresholds indicated greater rod function loss in the macula, which correlated with increasing AMD group severity. RITslope, which captures the spatial change in the rate of dark adaptation, increased with AMD severity (P < 0.0001). Three rod function phenotypes emerged: RF1, normal rod function; RF2, normal scotopic thresholds but slowed dark adaptation; and RF3, elevated scotopic thresholds with slowed dark adaptation. Dark adaptation was slowed at all loci with SDD or EZ band disruption, and at 32% of loci with no local structural changes. Conclusions Three rod function phenotypes were defined from combined measurement of scotopic threshold and dark adaptation. Spatial changes in dark adaptation across the macula were captured with RITslope, which may be a useful outcome measure for functional studies of AMD. PMID:29847647
Flynn, Oliver J; Cukras, Catherine A; Jeffrey, Brett G
2018-05-01
To examine spatial changes in rod-mediated function in relationship to local structural changes across the central retina in eyes with a spectrum of age-related macular degeneration (AMD) disease severity. Participants were categorized into five AMD severity groups based on fundus features. Scotopic thresholds were measured at 14 loci spanning ±18° along the vertical meridian from one eye of each of 42 participants (mean = 71.7 ± 9.9 years). Following a 30% bleach, dark adaptation was measured at eight loci (±12°). Rod intercept time (RIT) was defined from the time to detect a -3.1 log cd/m2 stimulus. RITslope was defined from the linear fit of RIT with decreasing retinal eccentricity. The presence of subretinal drusenoid deposits (SDD), ellipsoid (EZ) band disruption, and drusen at the test loci was evaluated using optical coherence tomography. Scotopic thresholds indicated greater rod function loss in the macula, which correlated with increasing AMD group severity. RITslope, which captures the spatial change in the rate of dark adaptation, increased with AMD severity (P < 0.0001). Three rod function phenotypes emerged: RF1, normal rod function; RF2, normal scotopic thresholds but slowed dark adaptation; and RF3, elevated scotopic thresholds with slowed dark adaptation. Dark adaptation was slowed at all loci with SDD or EZ band disruption, and at 32% of loci with no local structural changes. Three rod function phenotypes were defined from combined measurement of scotopic threshold and dark adaptation. Spatial changes in dark adaptation across the macula were captured with RITslope, which may be a useful outcome measure for functional studies of AMD.
Li, Jinjiang; Patel, Dhaval; Wang, George
2017-03-01
Spray-dried dispersions (SDDs) have become an important formulation technology for the pharmaceutical product development of poorly water-soluble (PWS) compounds. Although this technology is now widely used in the industry, especially in the early-phase development, the lack of mechanistic understanding still causes difficulty in selecting excipients and predicting stability of SDD-based drug products. In this review, the authors aim to discuss several principles of polymer science pertaining to the development of SDDs, in terms of selecting polymers and solvents, optimizing drug loading, as well as assessing physical stability on storage and supersaturation maintenance after dissolution, from both thermodynamic and kinetic considerations. In order to choose compatible solvents with both polymers and active pharmaceutical ingredients (APIs), a symmetric Flory-Huggins interaction (Δχ ∼0) approach was introduced. Regarding spray drying of polymer-API solutions, low critical solution temperature (LCST) was discussed for setting the inlet temperature for drying. In addition, after being exposed to moisture, SDDs are practically converted to ternary systems with asymmetric Flory-Huggins interactions, which are thermodynamically not favored. In this case, the kinetics of phase separation plays a significant role during the storage and dissolution of SDD-based drug products. The impact of polymers on the supersaturation maintenance of APIs in dissolution media was also discussed. Moreover, the nature of SDDs, with reference to solid solution and the notion of solid solubility, was examined in the context of pharmaceutical application. Finally, the importance of robust analytical techniques to characterize the SDD-based drug products was emphasized, considering their complexity.
Schwartz, James R; Rocchetta, Heather; Asawanonda, Pravit; Luo, Fangyi; Thomas, Jennifer H
2009-01-01
Scalp seborrheic dermatitis and dandruff (SD/D) are chronic conditions requiring long-term treatment. There is a common belief that patients frequently experience decreasing benefits over time when using a single product. This physiologic accommodation is termed tachyphylaxis. To systematically investigate the anecdotal belief that tachyphylaxis occurs in long-term treatment of SD/D using quantitative clinical assessments. An international questionnaire completed by 722 dermatologists assessed the belief of tachyphylaxis incidence with pyrithione zinc (PTZ)-based shampoos, time course, occurrence relative to active ingredients, and effect of switching products. Two double-blind, randomized, clinical evaluations were conducted, 24- and 48-week studies, whereby a 1% PTZ shampoo, a 2% PTZ shampoo, or a matched placebo control shampoo was used by each subject for the duration of the study. Dermatologists assessed the adherent scalp flaking (scale of 0-10) at baseline and at specified intervals. Sixty-four per cent of responding dermatologists believed tachyphylaxis occurred with PTZ products, and most felt that tachyphylaxis occurred within 3 months of use. Evaluation of mean treatment responses vs. placebo and individual responses as a function of study duration showed a consistent benefit for all products at all time points; therefore, no evidence for tachyphylaxis was found (within 48 weeks of treatment). No evidence for tachyphylaxis in SD/D treatment by PTZ-based shampoos was found. Compliance could explain the decreasing response rate seen over time; the solution is to choose an affordable therapeutic product that is effective long term without cosmetic trade-offs.
Deutsch, Eliza S; Alameddine, Ibrahim; El-Fadel, Mutasem
2018-02-15
The launch of the Landsat 8 in February 2013 extended the life of the Landsat program to over 40 years, increasing the value of using Landsat to monitor long-term changes in the water quality of small lakes and reservoirs, particularly in poorly monitored freshwater systems. Landsat-based water quality hindcasting often incorporate several Landsat sensors in an effort to increase the temporal range of observations; yet the transferability of water quality algorithms across sensors remains poorly examined. In this study, several empirical algorithms were developed to quantify chlorophyll-a, total suspended matter (TSM), and Secchi disk depth (SDD) from surface reflectance measured by Landsat 7 ETM+ and Landsat 8 OLI sensors. Sensor-specific multiple linear regression models were developed by correlating in situ water quality measurements collected from a semi-arid eutrophic reservoir with band ratios from Landsat ETM+ and OLI sensors, along with ancillary data (water temperature and seasonality) representing ecological patterns in algae growth. Overall, ETM+-based models outperformed (adjusted R 2 chlorophyll-a = 0.70, TSM = 0.81, SDD = 0.81) their OLI counterparts (adjusted R 2 chlorophyll-a = 0.50, TSM = 0.58, SDD = 0.63). Inter-sensor differences were most apparent for algorithms utilizing the Blue spectral band. The inclusion of water temperature and seasonality improved the power of TSM and SDD models.
NASA Astrophysics Data System (ADS)
Shoop, Brian; Johnston, Michael; Goehring, Richard; Moneyhun, Jon; Skibba, Brian
2006-05-01
MDARS is a Semi-autonomous unmanned ground vehicle with intrusion detection & assessment, product & barrier assessment payloads. Its functions include surveillance, security, early warning, incident first response and product and barrier status primarily focused on a depot/munitions security mission at structured/semi-structured facilities. MDARS is in Systems Development and Demonstration (SDD) under the Product Manager for Force Protection Systems (PM-FPS). MDARS capabilities include semi-autonomous navigation, obstacle avoidance, motion detection, day and night imagers, radio frequency tag inventory/barrier assessment and audio challenge and response. Four SDD MDARS Patrol Vehicles have been undergoing operational evaluation at Hawthorne Army Depot, NV (HWAD) since October 2004. Hawthorne personnel were trained to administer, operate and maintain the system in accordance with the US Army Military Police School (USAMPS) Concept of Employment and the PM-FPS MDARS Integrated Logistic Support Plan. The system was subjected to intensive periods of evaluation under the guidance and control of the Army Test and Evaluation Center (ATEC) and PM-FPS. Significantly, in terms of User acceptance, the system has been under the "operational control" of the installation performing security and force protection missions in support of daily operations. This evaluation is intended to assess MDARS operational effectiveness in an operational environment. Initial observations show that MDARS provides enhanced force protection, can potentially reduce manpower requirements by conducting routine tasks within its design capabilities and reduces Soldier exposure in the initial response to emerging incidents and situations. Success of the MDARS program has been instrumental in the design and development of two additional robotic force protection programs. The first was the USAF Force Protection Battle Lab sponsored Remote Detection Challenge & Response (REDCAR) concept demonstration executed by the Air Force Robotics Lab (AFRL). The REDCAR used an MDARS PUV as the central robotic technology and expanded the concept to incorporate a smaller high speed platform (SCOUT) equipped with lethal, non-lethal and challenge components as an engagement platform and, in a marsupial configuration on the MDARS, a small UGV that can be deployed to investigate close quarters areas. The Family of Integrated Rapid Response Equipment (FIRRE) program further expands these concepts by incorporating and adapting other mobile/tactical force protection equipment with a more robust Unmanned Ground Vehicle into an "Expeditionary" configuration to provide the current force with a rapidly deployable force protection system that can operate in austere less structured and protected environments. A USAMPS/ MANCEN sponsored "FIRRE System Demonstration" in Iraq is scheduled to begin in FY '07.
NASA Astrophysics Data System (ADS)
Salge, T.; Palasse, L.; Berlin, J.; Hansen, B.; Terborg, R.; Falke, M.
2013-12-01
Introduction: Characterization at the micro- to nano-scale is crucial for understanding many processes in earth, planetary, material and biological sciences. The composition of thin electron transparent samples can be analyzed in the nm-range using transmission electron microscopes (TEM) or, specific sample holders provided, in the field emission scanning electron microscope (FE-SEM). Nevertheless both methods often require complex sample preparation. An alternative method is to analyze bulk samples with a FE-SEM. In order to decrease the excitation volume for generated X-rays, low accelerating voltages (HV<10) are required. Consequently, only low to intermediate energy X-ray lines can be evaluated and many peak overlaps have to be deconvoluted since the high energy range is not available. Methods: A BRUKER Quantax EDS system with an XFlash Silicon Drift Detector acquired EDS spectra in spectrum images. To separate overlapping peaks, an extended atomic database [1] was used. For single channel EDS the electron beam current, solid angle, take-off angle and exposure time can be optimized to investigate the element composition. Multiple SDD setups ensure an even higher efficiency and larger collection angles for the X-ray analysis than single channel detectors. Shadowing effects are minimized in element distribution maps so that samples can be investigated quickly and sometimes in a close to natural state, with little preparation. A new type of EDS detector, the annular four channel SDD (XFlash 5060F), is placed between the pole piece and sample. It covers a very large solid angle (1.1 sr) and allows sufficient data collection at low beam currents on beam sensitive samples with substantial surface topography. Examples of applications: Results demonstrate that SDD-based EDS analysis contributes essential information on the structure at the micro- to nano scale of the investigated sample types. These include stardust analogue impact experiments [2], Chicxulub asteroid impactites [3,4], ore characterization of the Sudbury igneous complex [5], biomineralization in bacteria and insects [6], and characterization of ceramics [7] and ceramic metal joints [8]. We conclude that improvements in SDD and pulse processor technology including multi-detector and multi-segment options provide new insights because a vast amount of detailed information can be collected in a short period of time. Using the XFlash QUAD 5060F, samples can be analyzed rapidly at low beam current without carbon coating. [1] A. Assmann, A. and M. Wendt 2003. Spectrochim. Acta Part B, 58: 711-716. [2] A.T. Kearsley et al. 2013. 44th LPSC, 18-22.03.2013, The Woodlands, USA: #1910. [3] P. Schulte et al. 2010. Science 327: 1214-1218. [4] M. Nelson et al. 2012. GCA 86: 1-20. [5] Salge et al. 2013. LPI Contrib .No. 1737: 89. [6] M. Falke et al. 2013. EURO BioMat. 23-24.04.2013, Weimar, Germany. [7] H. Yurdakul et al. 2013.accepted for MC 2013, 25-30.08.2013, Regensburg, Germany [8] O. Tunckan 2010. PhD thesis. Anadolu University, Eskisehir, Turkey.
Gustafsson, Margareta; Blomberg, Karin; Holmefur, Marie
2015-07-01
The Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale evaluates the student nurses' perception of the learning environment and supervision within the clinical placement. It has never been tested in a replication study. The aim of the present study was to evaluate the test-retest reliability of the CLES + T scale. The CLES + T scale was administered twice to a group of 42 student nurses, with a one-week interval. Test-retest reliability was determined by calculations of Intraclass Correlation Coefficients (ICCs) and weighted Kappa coefficients. Standard Error of Measurements (SEM) and Smallest Detectable Difference (SDD) determined the precision of individual scores. Bland-Altman plots were created for analyses of systematic differences between the test occasions. The results of the study showed that the stability over time was good to excellent (ICC 0.88-0.96) in the sub-dimensions "Supervisory relationship", "Pedagogical atmosphere on the ward" and "Role of the nurse teacher". Measurements of "Premises of nursing on the ward" and "Leadership style of the manager" had lower but still acceptable stability (ICC 0.70-0.75). No systematic differences occurred between the test occasions. This study supports the usefulness of the CLES + T scale as a reliable measure of the student nurses' perception of the learning environment within the clinical placement at a hospital. Copyright © 2015 Elsevier Ltd. All rights reserved.
Evaluating the Performance of a Commercial Silicon Drift Detector for X-ray Microanalysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenik, Edward A
2011-01-01
Silicon drift detectors (SDDs) are rapidly becoming the energy dispersive spectrometer (EDS) of choice, especially for scanning electron microscopy x-ray microanalysis. The complementary features of large active areas (i.e., high collection angle) and high count rate capability of these detector contribute to their popularity, as well as the absence of liquid nitrogen cooling and good energy resolution of these detectors. The performance of an EDAX Apollo 40 SDD on a JEOL 6500F SEM is discussed. The larger detector resulted in an significant increase (~3.5x) in geometric collection efficiency compared to the original 10mm2 Si(Li) detector that it replaced. The SEMmore » can provide high beam currents (up to 200nA in some conditions) at small probe diameters. The high count rate capability of the SDD and the high current capability of the SEM compliment each other and provide excellent EDS analytical capabilities for both single point and spectrum imaging applications.« less
Source position verification and dosimetry in HDR brachytherapy using an EPID.
Smith, R L; Taylor, M L; McDermott, L N; Haworth, A; Millar, J L; Franich, R D
2013-11-01
Accurate treatment delivery in high dose rate (HDR) brachytherapy requires correct source dwell positions and dwell times to be administered relative to each other and to the surrounding anatomy. Treatment delivery inaccuracies predominantly occur for two reasons: (i) anatomical movement or (ii) as a result of human errors that are usually related to incorrect implementation of the planned treatment. Electronic portal imaging devices (EPIDs) were originally developed for patient position verification in external beam radiotherapy and their application has been extended to provide dosimetric information. The authors have characterized the response of an EPID for use with an (192)Ir brachytherapy source to demonstrate its use as a verification device, providing both source position and dosimetric information. Characterization of the EPID response using an (192)Ir brachytherapy source included investigations of reproducibility, linearity with dose rate, photon energy dependence, and charge build-up effects associated with exposure time and image acquisition time. Source position resolution in three dimensions was determined. To illustrate treatment verification, a simple treatment plan was delivered to a phantom and the measured EPID dose distribution compared with the planned dose. The mean absolute source position error in the plane parallel to the EPID, for dwells measured at 50, 100, and 150 mm source to detector distances (SDD), was determined to be 0.26 mm. The resolution of the z coordinate (perpendicular distance from detector plane) is SDD dependent with 95% confidence intervals of ± 0.1, ± 0.5, and ± 2.0 mm at SDDs of 50, 100, and 150 mm, respectively. The response of the EPID is highly linear to dose rate. The EPID exhibits an over-response to low energy incident photons and this nonlinearity is incorporated into the dose calibration procedure. A distance (spectral) dependent dose rate calibration procedure has been developed. The difference between measured and planned dose is less than 2% for 98.0% of pixels in a two-dimensional plane at an SDD of 100 mm. Our application of EPID dosimetry to HDR brachytherapy provides a quality assurance measure of the geometrical distribution of the delivered dose as well as the source positions, which is not possible with any current HDR brachytherapy verification system.
Chih, Adrian Ng Wei; Hieng, Albert Wong Sii; Rahman, Noor Azman A.; Abdullah, Jafri Malin
2017-01-01
Introduction Symptomatic chronic subdural hematomas (CSDH) remain one of the most frequent diagnoses in current neurosurgical practice. Burr-hole craniostomy with irrigation and placement of close-system drainage is the current recommended surgery for symptomatic CSDH. The aim of this study is to perform a direct comparison between two surgical techniques in the treatment of symptomatic CSDH, which have been proven in previous studies to be efficient. Our main objective was to compare the efficacy of placement of a subperiosteal drain (SPD) and a subdural drain (SDD) following single burr-hole craniostomy and irrigation, and to demonstrate any significant differences in terms of overall surgical complications, functional outcome at three months and mortality rate. Materials and Methods The study was carried out in two local neurosurgical centres. The SPD group was performed in Hospital Umum Sarawak (HUS) and the SDD group was performed in Hospital Sultanah Aminah Johor Bahru (HSAJB), from 1 January 2012 till 30 January 2014 with a total of 30 patients in both treatment groups. Results Overall, there were no statistically significant difference in terms of patient general characteristics, pre-operative and post-operative symptoms, Markwalder grades, post-operative hematoma volume and recurrence, mortality and functional outcome at discharge and at three month follow-up between both groups. Albeit not achieving statistical significance, we observed a lower rate of surgical complication especially for post-operative intracranial hematoma with placement of the SPD system. Conclusions Our study concludes that both treatment methods proved to be highly effective in the treatment of CSDH. However, with a lower overall surgical complication rate, treatment with single burr-hole craniostomy, irrigation and placement of the SPD system can be considered a treatment of choice for the management of symptomatic CSDH. PMID:28381926
Chih, Adrian Ng Wei; Hieng, Albert Wong Sii; Rahman, Noor Azman A; Abdullah, Jafri Malin
2017-03-01
Symptomatic chronic subdural hematomas (CSDH) remain one of the most frequent diagnoses in current neurosurgical practice. Burr-hole craniostomy with irrigation and placement of close-system drainage is the current recommended surgery for symptomatic CSDH. The aim of this study is to perform a direct comparison between two surgical techniques in the treatment of symptomatic CSDH, which have been proven in previous studies to be efficient. Our main objective was to compare the efficacy of placement of a subperiosteal drain (SPD) and a subdural drain (SDD) following single burr-hole craniostomy and irrigation, and to demonstrate any significant differences in terms of overall surgical complications, functional outcome at three months and mortality rate. The study was carried out in two local neurosurgical centres. The SPD group was performed in Hospital Umum Sarawak (HUS) and the SDD group was performed in Hospital Sultanah Aminah Johor Bahru (HSAJB), from 1 January 2012 till 30 January 2014 with a total of 30 patients in both treatment groups. Overall, there were no statistically significant difference in terms of patient general characteristics, pre-operative and post-operative symptoms, Markwalder grades, post-operative hematoma volume and recurrence, mortality and functional outcome at discharge and at three month follow-up between both groups. Albeit not achieving statistical significance, we observed a lower rate of surgical complication especially for post-operative intracranial hematoma with placement of the SPD system. Our study concludes that both treatment methods proved to be highly effective in the treatment of CSDH. However, with a lower overall surgical complication rate, treatment with single burr-hole craniostomy, irrigation and placement of the SPD system can be considered a treatment of choice for the management of symptomatic CSDH.
A novel omega3-fatty acid desaturase involved in the biosynthesis of eicosapentaenoic acid.
Pereira, Suzette L; Huang, Yung-Sheng; Bobik, Emil G; Kinney, Anthony J; Stecca, Kevin L; Packer, Jeremy C L; Mukerji, Pradip
2004-01-01
Long-chain n-3 PUFAs (polyunsaturated fatty acids) such as EPA (eicosapentaenoic acid; 20:5 n-3) have important therapeutic and nutritional benefits in humans. In plants, cyanobacteria and nematodes, omega3-desaturases catalyse the formation of these n-3 fatty acids from n-6 fatty acid precursors. Here we describe the isolation and characterization of a gene ( sdd17 ) derived from an EPA-rich fungus, Saprolegnia diclina, that encodes a novel omega3-desaturase. This gene was isolated by PCR amplification of an S. diclina cDNA library using oligonucleotide primers corresponding to conserved regions of known omega3-desaturases. Expression of this gene in Saccharomyces cerevisiae, in the presence of various fatty acid substrates, revealed that the recombinant protein could exclusively desaturate 20-carbon n-6 fatty acid substrates with a distinct preference for ARA (arachidonic acid; 20:4 n-6), converting it into EPA. This activity differs from that of the known omega3-desaturases from any organism. Plant and cyanobacterial omega3-desaturases exclusively desaturate 18-carbon n-6 PUFAs, and a Caenorhabditis elegans omega3-desaturase preferentially desaturated 18-carbon PUFAs over 20-carbon substrates, and could not convert ARA into EPA when expressed in yeast. The sdd17 -encoded desaturase was also functional in transgenic somatic soya bean embryos, resulting in the production of EPA from exogenously supplied ARA, thus demonstrating its potential for use in the production of EPA in transgenic oilseed crops. PMID:14651475
Sigaut, Lorena; Pearson, John E.; Colman-Lerner, Alejandro; Ponce Dawson, Silvina
2014-01-01
The gradient of Bicoid (Bcd) is key for the establishment of the anterior-posterior axis in Drosophila embryos. The gradient properties are compatible with the SDD model in which Bcd is synthesized at the anterior pole and then diffuses into the embryo and is degraded with a characteristic time. Within this model, the Bcd diffusion coefficient is critical to set the timescale of gradient formation. This coefficient has been measured using two optical techniques, Fluorescence Recovery After Photobleaching (FRAP) and Fluorescence Correlation Spectroscopy (FCS), obtaining estimates in which the FCS value is an order of magnitude larger than the FRAP one. This discrepancy raises the following questions: which estimate is "correct''; what is the reason for the disparity; and can the SDD model explain Bcd gradient formation within the experimentally observed times? In this paper, we use a simple biophysical model in which Bcd diffuses and interacts with binding sites to show that both the FRAP and the FCS estimates may be correct and compatible with the observed timescale of gradient formation. The discrepancy arises from the fact that FCS and FRAP report on different effective (concentration dependent) diffusion coefficients, one of which describes the spreading rate of the individual Bcd molecules (the messengers) and the other one that of their concentration (the message). The latter is the one that is more relevant for the gradient establishment and is compatible with its formation within the experimentally observed times. PMID:24901638
Sigaut, Lorena; Pearson, John E; Colman-Lerner, Alejandro; Ponce Dawson, Silvina
2014-06-01
The gradient of Bicoid (Bcd) is key for the establishment of the anterior-posterior axis in Drosophila embryos. The gradient properties are compatible with the SDD model in which Bcd is synthesized at the anterior pole and then diffuses into the embryo and is degraded with a characteristic time. Within this model, the Bcd diffusion coefficient is critical to set the timescale of gradient formation. This coefficient has been measured using two optical techniques, Fluorescence Recovery After Photobleaching (FRAP) and Fluorescence Correlation Spectroscopy (FCS), obtaining estimates in which the FCS value is an order of magnitude larger than the FRAP one. This discrepancy raises the following questions: which estimate is "correct''; what is the reason for the disparity; and can the SDD model explain Bcd gradient formation within the experimentally observed times? In this paper, we use a simple biophysical model in which Bcd diffuses and interacts with binding sites to show that both the FRAP and the FCS estimates may be correct and compatible with the observed timescale of gradient formation. The discrepancy arises from the fact that FCS and FRAP report on different effective (concentration dependent) diffusion coefficients, one of which describes the spreading rate of the individual Bcd molecules (the messengers) and the other one that of their concentration (the message). The latter is the one that is more relevant for the gradient establishment and is compatible with its formation within the experimentally observed times.
A novel multi-cell silicon drift detector for Low Energy X-Ray Fluorescence (LEXRF) spectroscopy
NASA Astrophysics Data System (ADS)
Bufon, J.; Ahangarianabhari, M.; Bellutti, P.; Bertuccio, G.; Carrato, S.; Cautero, G.; Fabiani, S.; Giacomini, G.; Gianoncelli, A.; Giuressi, D.; Grassi, M.; Malcovati, P.; Menk, R. H.; Picciotto, A.; Piemonte, C.; Rashevskaya, I.; Rachevski, A.; Stolfa, A.; Vacchi, A.; Zampa, G.; Zampa, N.
2014-12-01
The TwinMic spectromicroscope at Elettra is a multipurpose experimental station for full-field and scanning imaging modes and simultaneous acquisition of X-ray fluorescence. The actual LEXRF detection setup consists of eight single-cell Silicon Drift Detectors (SDD) in an annular configuration. Although they provide good performances in terms of both energy resolution and low-energy photon detection efficiency, they cover just about 4% of the whole photoemission solid angle. This is the main limitation of the present detection system, since large part of the emitted photons is lost and consequently a high acquisition time is required. In order to increase the solid angle, a new LEXRF detection system is being developed within a large collaboration of several institutes. The system, composed of 4 trapezoidal multi-cell silicon drift detectors, covers up to 40% of the photoemission hemisphere, so that this geometry provides a 10 times improvement over the present configuration. First measurements in the laboratory and on the TwinMic beamline have been performed in order to characterize a single trapezoidal detector, configured and controlled by means of two multichannel ASICs, which provide preamplification, shaping and peak-stretching, connected to acquisition electronics based on fast ADCs and FPGA and working under vacuum.
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Geronimo, G.; Fried, J.; Rehak, P.
We present an application-specific integrated circuit (ASIC) for high-resolution x-ray spectrometers (XRS). The ASIC reads out signals from pixelated silicon drift detectors (SDDs). The pixel does not have an integrated field effect transistor (FET); rather, readout is accomplished by wire-bonding the anodes to the inputs of the ASIC. The ASIC dissipates 32 mW, and offers 16 channels of low-noise charge amplification, high-order shaping with baseline stabilization, discrimination, a novel pile-up rejector, and peak detection with an analog memory. The readout is sparse and based on custom low-power tristatable low-voltage differential signaling (LPT-LVDS). A unit of 64 SDD pixels, read outmore » by four ASICs, covers an area of 12.8 cm{sup 2} and dissipates with the sensor biased about 15 mW/cm{sup 2}. As a tile-based system, the 64-pixel units cover a large detection area. Our preliminary measurements at -44 C show a FWHM of 145 eV at the 5.9 keV peak of a {sup 55}Fe source, and less than 80 eV on a test-pulse line at 200 eV.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
DE GERONIMO,G.; CHEN, W.; FRIED, J.
We present an application specific integrated circuit (ASIC) for high-resolution x-ray spectrometers. The ASIC is designed to read out signals from a pixelated silicon drift detector (SDD). Each hexagonal pixel has an area of 15 mmz and an anode capacitance of less than 100 fF. There is no integrated Field Effect transistor (FET) in the pixel, rather, the readout is done by wirebonding the anodes to the inputs of the ASIC. The ASIC provides 14 channels of low-noise charge amplification, high-order shaping with baseline stabilization, and peak detection with analog memory. The readout is sparse and based on low voltagemore » differential signaling. An interposer provides all the interconnections required to bias and operate the system. The channel dissipates 1.6 mW. The complete 14-pixel unit covers an area of 210 mm{sup 2}, dissipates 12 mW cm{sup -2}, and can be tiled to cover an arbitrarily large detection area. We measured a preliminary resolution of 172 eV at -35 C on the 6 keV peak of a {sup 55}Fe source.« less
Agile Port and High Speed Ship Technologies, Vol 1: FY05 Projects 3-6 and 8-10
2008-07-02
Computational Fluid Dynamics DTMB - David Taylor Model Basin JVR - Jet Velocity Ratio NSWCCD - Naval Surface Warfare Center, Carderock Division SDD - Systems...immature current state of the technology employed for the reactor system (multiple closed Brayton Cycle, Helium Cooled Gas reactors); (iii) several
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pantelis, E.; Moutsatsos, A.; Zourari, K.
Purpose: To measure the output factors (OFs) of the small fields formed by the variable aperture collimator system (iris) of a CyberKnife (CK) robotic radiosurgery system, and determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for a microchamber and four diode detectors. Methods: OF measurements were performed using a PTW PinPoint 31014 microchamber, four diode detectors (PTW-60017, -60012, -60008, and the SunNuclear EDGE detector), TLD-100 microcubes, alanine dosimeters, EBT films, and polymer gels for the 5 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm irismore » collimators at 650 mm, 800 mm, and 1000 mm source to detector distance (SDD). The alanine OF measurements were corrected for volume averaging effects using the 3D dose distributions registered in polymer gel dosimeters. k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for the PinPoint microchamber and the diode dosimeters were calculated through comparison against corresponding polymer gel, EBT, alanine, and TLD results. Results: Experimental OF results are presented for the array of dosimetric systems used. The PinPoint microchamber was found to underestimate small field OFs, and a k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor ranging from 1.127 {+-} 0.022 (for the 5 mm iris collimator) to 1.004 {+-} 0.010 (for the 15 mm iris collimator) was determined at the reference SDD of 800 mm. The PinPoint k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factor was also found to increase with decreasing SDD; k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values equal to 1.220 {+-} 0.028 and 1.077 {+-} 0.016 were obtained for the 5 mm iris collimator at 650 mm and 1000 mm SDD, respectively. On the contrary, diode detectors were found to overestimate small field OFs and a correction factor equal to 0.973 {+-} 0.006, 0.954 {+-} 0.006, 0.937 {+-} 0.007, and 0.964 {+-} 0.006 was measured for the PTW-60017, -60012, -60008 and the EDGE diode detectors, respectively, for the 5 mm iris collimator at 800 mm SDD. The corresponding correction factors for the 15 mm iris collimator were found equal to 0.997 {+-} 0.010, 0.994 {+-} 0.009, 0.988 {+-} 0.010, and 0.986 {+-} 0.010, respectively. No correlation of the diode k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors with SDD was observed. Conclusions: This work demonstrates an experimental procedure for the determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors required to obtain small field OF results of increased accuracy.« less
Depression and Self-Esteem in Early Adolescence.
Tripković, Ingrid; Roje, Romilda; Krnić, Silvana; Nazor, Mirjana; Karin, Željka; Čapkun, Vesna
2015-06-01
Depression prevalence has increased in the last few decades, affecting younger age groups. The aim of this research was to determine the range of depression and low self-esteem in elementary school children in the city of Split. Testing was carried out at school and the sample comprised 1,549 children (714 boys and 832 girls, aged 13). Two psychological instruments were used: the Coopersmith Self-Esteem Inventory (SEI) and the Children and Adolescent Depression Scale (SDD). The average value of scores obtained by SEI test was 17.8 for all tested children. No statistically significant difference was found be-tween boys and girls. It was found that 11.9% of children showed signs of clinically significant depression, and 16.2% showed signs of depression. Statistically significant association between low self-esteem and clinically significant depression was found. No statistically significant difference among boys and girls according to dimension of cognitive depression was found, whereas statistically significant level of emotional depression was higher in girls than boys. It was found that both dimensions of depression decreased proportionally with the increase of SEI test score values: cognitive and emotional dimension of depression. The results of this study show that it is necessary to provide early detection of emotional difficulties in order to prevent serious mental disorders. Copyright© by the National Institute of Public Health, Prague 2015.
Prospects for higher spatial resolution quantitative X-ray analysis using transition element L-lines
NASA Astrophysics Data System (ADS)
Statham, P.; Holland, J.
2014-03-01
Lowering electron beam kV reduces electron scattering and improves spatial resolution of X-ray analysis. However, a previous round robin analysis of steels at 5 - 6 kV using Lα-lines for the first row transition elements gave poor accuracies. Our experiments on SS63 steel using Lα-lines show similar biases in Cr and Ni that cannot be corrected with changes to self-absorption coefficients or carbon coating. The inaccuracy may be caused by different probabilities for emission and anomalous self-absorption for the La-line between specimen and pure element standard. Analysis using Ll(L3-M1)-lines gives more accurate results for SS63 plausibly because the M1-shell is not so vulnerable to the atomic environment as the unfilled M4,5-shell. However, Ll-intensities are very weak and WDS analysis may be impractical for some applications. EDS with large area SDD offers orders of magnitude faster analysis and achieves similar results to WDS analysis with Lα-lines but poorer energy resolution precludes the use of Ll-lines in most situations. EDS analysis of K-lines at low overvoltage is an alternative strategy for improving spatial resolution that could give higher accuracy. The trade-off between low kV versus low overvoltage is explored in terms of sensitivity for element detection for different elements.
High-Performance Cryogenic Designs for OMEGA and the National Ignition Facility
NASA Astrophysics Data System (ADS)
Goncharov, V. N.; Collins, T. J. B.; Marozas, J. A.; Regan, S. P.; Betti, R.; Boehly, T. R.; Campbell, E. M.; Froula, D. H.; Igumenshchev, I. V.; McCrory, R. L.; Myatt, J. F.; Radha, P. B.; Sangster, T. C.; Shvydky, A.
2016-10-01
The main advantage of laser symmetric direct drive (SDD) is a significantly higher coupled drive laser energy to the hot-spot internal energy at stagnation compared to that of laser indirect drive. Because of coupling losses resulting from cross-beam energy transfer (CBET), however, reaching ignition conditions on the NIF with SDD requires designs with excessively large in-flight aspect ratios ( 30). Results of cryogenic implosions performed on OMEGA show that such designs are unstable to short-scale nonuniformity growth during shell implosion. Several CBET reduction strategies have been proposed in the past. This talk will discuss high-performing designs using several CBET-mitigation techniques, including using drive laser beams smaller than the target size and wavelength detuning. Designs that are predicted to reach alpha burning regimes as well as a gain of 10 to 40 at the NIF-scale will be presented. Hydrodynamically scaled OMEGA designs with similar CBET-reduction techniques will also be discussed. This material is based upon work supported by the Department Of Energy National Nuclear Security Administration under Award Number DE-NA0001944.
NASA Astrophysics Data System (ADS)
Newbury, Dale E.; Ritchie, Nicholas W. M.
2014-09-01
Quantitative electron-excited x-ray microanalysis by scanning electron microscopy/silicon drift detector energy dispersive x-ray spectrometry (SEM/SDD-EDS) is capable of achieving high accuracy and high precision equivalent to that of the high spectral resolution wavelength dispersive x-ray spectrometer even when severe peak interference occurs. The throughput of the SDD-EDS enables high count spectra to be measured that are stable in calibration and resolution (peak shape) across the full deadtime range. With this high spectral stability, multiple linear least squares peak fitting is successful for separating overlapping peaks and spectral background. Careful specimen preparation is necessary to remove topography on unknowns and standards. The standards-based matrix correction procedure embedded in the NIST DTSA-II software engine returns quantitative results supported by a complete error budget, including estimates of the uncertainties from measurement statistics and from the physical basis of the matrix corrections. NIST DTSA-II is available free for Java-platforms at: http://www.cstl.nist.gov/div837/837.02/epq/dtsa2/index.html).
Kim, Soo Young; Kim, Se Hyun; Kim, Su Na; Kim, Ah-Reum; Kim, Yu Ri; Kim, Min Jung; Park, Won-Seok; Lee, John Hwan; Jung, Won Hee; Lee, Yang Won; Choe, Yong Beom; Ahn, Kyu Joong
2016-05-01
We investigated the distribution of Malassezia yeast in 120 Chinese (20 patients from each of six cities) and 20 Korean patients with scalp seborrheic dermatitis (SD) and dandruff (SD/D) using ITS1 and ITS2 polymerase chain reaction-restriction fragment length polymorphism. Bioactivity was studied by quantifying sebum lipid production by human primary sebocytes and inflammatory cytokine, interleukin-8 (IL-8) production was studied by exposing HaCaT keratinocytes with extracts of five standard Malassezia strains; M. globosa, M. restricta, M. sympodialis, M. dermatis and M. slooffiae. M. restricta and M. globosa were the most frequently encountered species from both Chinese and Korean patients. These two Malassezia species also promoted neutral lipid synthesis although the result was not statistically significant and induced significant increase in IL-8 production among the five Malassezia species studied. The study suggests a possible role of these organisms in the pathogenesis of SD/D. © 2016 Blackwell Verlag GmbH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palmer, M.E.
1997-12-05
This V and V Report includes analysis of two revisions of the DMS [data management system] System Requirements Specification (SRS) and the Preliminary System Design Document (PSDD); the source code for the DMS Communication Module (DMSCOM) messages; the source code for selected DMS Screens, and the code for the BWAS Simulator. BDM Federal analysts used a series of matrices to: compare the requirements in the System Requirements Specification (SRS) to the specifications found in the System Design Document (SDD), to ensure the design supports the business functions, compare the discreet parts of the SDD with each other, to ensure thatmore » the design is consistent and cohesive, compare the source code of the DMS Communication Module with the specifications, to ensure that the resultant messages will support the design, compare the source code of selected screens to the specifications to ensure that resultant system screens will support the design, compare the source code of the BWAS simulator with the requirements to interface with DMS messages and data transfers relating to the BWAS operations.« less
Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.
Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao
2002-04-01
Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar dorsiflexion was significantly lower than that in palmar extension. In some cases, finger plethysmogram did not disappear during maximum inflation of the wrist-cuff (congruent with 250 mmHg), even in palmar extension and especially in palmar flexion, suggesting incomplete obstruction of radial and/or ulnar arteries during inflation. The results suggest that wrist-cuff devices in the present form are inadequate for self-measurement of blood pressure and, thus, are inadequate for general use or clinical and practical use. However, there is much possibility in wrist-cuff device and the accuracy and reliability of wrist-cuff device are warranted by an improvement of technology.
van Eck van der Sluijs, A; Oosterheert, J J; Ekkelenkamp, M B; Hoepelman, I M; Peters, Edgar J G
2012-06-01
Although Gram-negative micro-organisms are frequently associated with catheter-related bloodstream infections, the prognostic value and clinical implication of a positive catheter tip culture with Gram-negative micro-organisms without preceding bacteremia remains unclear. We determined the outcomes of patients with intravascular catheters colonized with these micro-organisms, without preceding positive blood cultures, and identified risk factors for the development of subsequent Gram-negative bacteremia. All patients with positive intravascular catheter tip cultures with Gram-negative micro-organisms at the University Medical Center, Utrecht, The Netherlands, between 2005 and 2009, were retrospectively studied. Patients with Gram-negative bacteremia within 48 h before catheter removal were excluded. The main outcome measure was bacteremia with Gram-negative micro-organisms. Other endpoints were length of the hospital stay, in-hospital mortality, secondary complications of Gram-negative bacteremia, and duration of intensive care admission. A total of 280 catheters from 248 patients were colonized with Gram-negative micro-organisms. Sixty-seven cases were excluded because of preceding positive blood cultures, leaving 213 catheter tips from 181 patients for analysis. In 40 (19%) cases, subsequent Gram-negative bacteremia developed. In multivariate analysis, arterial catheters were independently associated with subsequent Gram-negative bacteremia (odds ratio [OR] = 5.00, 95% confidence interval [CI]: 1.20-20.92), as was selective decontamination of the digestive tract (SDD) (OR = 2.47, 95% CI: 1.07-5.69). Gram-negative bacteremia in patients who received SDD was predominantly caused by cefotaxime (part of the SDD)-resistant organisms. Mortality was significantly higher in the group with subsequent Gram-negative bacteremia (35% versus 20%, OR = 2.12, 95% CI: 1.00-4.49). Patients with a catheter tip colonized with Gram-negative micro-organisms had a high chance of subsequent Gram-negative bacteremia from any cause. This may be clinically relevant, as starting antibiotic treatment pre-emptively in high-risk patients with Gram-negative micro-organisms cultured from arterial intravenous catheters may be beneficial.
The silicon drift detector for the IXO high-time resolution spectrometer
NASA Astrophysics Data System (ADS)
Lechner, Peter; Amoros, Carine; Barret, Didier; Bodin, Pierre; Boutelier, Martin; Eckhardt, Rouven; Fiorini, Carlo; Kendziorra, Eckhard; Lacombe, Karine; Niculae, Adrian; Pouilloux, Benjamin; Pons, Roger; Rambaud, Damien; Ravera, Laurent; Schmid, Christian; Soltau, Heike; Strüder, Lothar; Tenzer, Christoph; Wilms, Jörn
2010-07-01
The High Time Resolution Spectrometer (HTRS) is one of six scientific payload instruments of the International X-ray Observatory (IXO). HTRS is dedicated to the physics of matter at extreme density and gravity and will observe the X-rays generated in the inner accretion flows around the most compact massive objects, i.e. black holes and neutron stars. The study of their timing signature and in addition the simultaneous spectroscopy of the gravitationally shifted and broadened iron line allows for probing general relativity in the strong field regime and understanding the inner structure of neutron stars. As the sources to be observed by HTRS are the brightest in the X-ray sky and the studies require good photon statistics the instrument design is driven by the capability to operate at extremely high count rates. The HTRS instrument is based on a monolithic array of Silicon Drift Detectors (SDDs) with 31 cells in a circular envelope and a sensitive volume of 4.5 cm2 × 450 μm. The SDD principle uses fast signal charge collection on an integrated amplifier by a focusing internal electrical field. It combines a large sensitive area and a small capacitance, thus facilitating good energy resolution and high count rate capability. The HTRS is specified to provide energy spectra with a resolution of 150 eV (FWHM at 6 keV) at high time resolution of 10 μsec and with high count rate capability up to a goal of 2.106 counts per second, corresponding to a 12 Crab equivalent source. As the HTRS is a non-imaging instrument and will target only point sources it is placed on axis but out of focus so that the spot is spread over the array of 31 SDD cells. The SDD array is logically organized in four independent 'quadrants', a dedicated 8-channel quadrant readout chip is in development.
IDA 2004 Cost Research Symposium: Investments in, Use of, and Management of Cost Research
2004-09-01
Database: None Publication: Technical Report Keywords: Government, Aircraft, SD&D, Production, Integration, Data Collection, Database, CER B- 71 ... Martin Plant in Marietta , Georgia,” IDA Paper P-3590, July 2001 “Econometric Modeling of Acquisition Category I Systems at the Raytheon Plant in...NAVSEA) ............................................................ B- 71 Naval Surface Warfare Center, Dahlgren Division (NSWCDD
NASA Astrophysics Data System (ADS)
Klingelhoefer, Goestar; Morris, Richard; Blumers, Mathias; Girones-Lopez, Jordi; Bernhardt, Bodo; Henkel, Hartmut; D'Uston, Claude; Brueckner, Johannes; Rodionov, Daniel; Strueder, Lothar
The Miniaturised Mössbauer Spectrometers MIMOS II on board the two NASA Mars Exploration Rovers (MER) have now collected valuable scientific data for more than ten years [1-4]. This mission has demonstrated that Mössbauer spectroscopy is extremely valuable for the in situ exploration of extraterrestrial bodies and the study of Fe-bearing samples. A MIMOS instrument was also on the scientific payload of the Russian mission Phobos Grunt [5]. The instrument MIMOS IIA originally developed for the ESA ExoMars mission (now 2018) will use newly de-signed Si-Drift detectors with circular geometry (SDD) [6,7] allowing high resolution X-ray fluorescence spectroscopy simultaneously to Mössbauer measurements. The new design of the improved MIMOS II instrument is reduced in total mass (less than 400 g). The sensorhead of MIMOS IIA will be equipped with a ring of Silicon Drift Detectors (SDD) optimized for the backscatter geometry of the miniaturized Mössbauer spectrometer. The main goal of the new detector system design was to combine high energy resolution at high counting rates and large detector area while making maximum use of the area close to the collimator of the 57Co Mössbauer source. The active area per SDD segment is 2x45 mm2. The energy resolution at 5.9 keV is < 280 eV at room temperature and 131 eV FWHM at -40oC. This performance will increase the signal to noise ratio (SNR) and reduce the integration time of Mössbauer measurement by a factor of up to 10. In addition to the Mössbauer analysis simultaneous acquisition of the X-ray fluorescence spectrum will provide data on the sample's elemental composition [7]. Preliminary studies at room temperature and normal pressure show detection of X-rays down to ~1 keV. A new control- and readout electronics for MIMOS IIA allows spectra acquisition at highest possible countrates available at about 360 mm2 total detector area. A prototype of MIMOS IIA has been tested successfully during a field test at Mauna Kea, Hawaii, as part of the international NASA JSC lead In-Situ Resource Utilization field tests 2010 and 2012. Acknowledgment: Funded by german space agency DLR under contract 50 QX 0603 and 50QX0802. References: [1] Klingelhöfer et al., J. Geophys. Res. 108(E12) (2003) [2] Klingelhöfer et al., Science 306 (2004) 1740-1745. [3] Morris et al., Science 305 (2004) 833-836. [4] Morris et al., J. Geophys. Res. 111 (2006) [5] Rodionov et al., Solar System Research Vol. 44, No. 5 (2010) pp. 362-370 [6] P. Lechner et al., Nucl. Instr. and Meth. A 377 (1996) 346-351 [7] M. Blumers et al., Nucl. Instr. and Meth. A 624 (2010) 277-281
do Amaral, Leonardo L.; Pavoni, Juliana F.; Sampaio, Francisco; Netto, Thomaz Ghilardi
2015-01-01
Despite individual quality assurance (QA) being recommended for complex techniques in radiotherapy (RT) treatment, the possibility of errors in dose delivery during therapeutic application has been verified. Therefore, it is fundamentally important to conduct in vivo QA during treatment. This work presents an in vivo transmission quality control methodology, using radiochromic film (RCF) coupled to the linear accelerator (linac) accessory holder. This QA methodology compares the dose distribution measured by the film in the linac accessory holder with the dose distribution expected by the treatment planning software. The calculated dose distribution is obtained in the coronal and central plane of a phantom with the same dimensions of the acrylic support used for positioning the film but in a source‐to‐detector distance (SDD) of 100 cm, as a result of transferring the IMRT plan in question with all the fields positioned with the gantry vertically, that is, perpendicular to the phantom. To validate this procedure, first of all a Monte Carlo simulation using PENELOPE code was done to evaluate the differences between the dose distributions measured by the film in a SDD of 56.8 cm and 100 cm. After that, several simple dose distribution tests were evaluated using the proposed methodology, and finally a study using IMRT treatments was done. In the Monte Carlo simulation, the mean percentage of points approved in the gamma function comparing the dose distribution acquired in the two SDDs were 99.92%±0.14%. In the simple dose distribution tests, the mean percentage of points approved in the gamma function were 99.85%±0.26% and the mean percentage differences in the normalization point doses were −1.41%. The transmission methodology was approved in 24 of 25 IMRT test irradiations. Based on these results, it can be concluded that the proposed methodology using RCFs can be applied for in vivo QA in RT treatments. PACS number: 87.55.Qr, 87.55.km, 87.55.N‐ PMID:26699306
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopec, Anna K.; Thompson, Chad M.; Kim, Suntae
2012-07-15
Continuous exposure to high concentrations of hexavalent chromium [Cr(VI)] in drinking water results in intestinal tumors in mice but not rats. Concentration-dependent gene expression effects were evaluated in female F344 rat duodenal and jejunal epithelia following 7 and 90 days of exposure to 0.3–520 mg/L (as sodium dichromate dihydrate, SDD) in drinking water. Whole-genome microarrays identified 3269 and 1815 duodenal, and 4557 and 1534 jejunal differentially expressed genes at 8 and 91 days, respectively, with significant overlaps between the intestinal segments. Functional annotation identified gene expression changes associated with oxidative stress, cell cycle, cell death, and immune response that weremore » consistent with reported changes in redox status and histopathology. Comparative analysis with B6C3F1 mouse data from a similarly designed study identified 2790 differentially expressed rat orthologs in the duodenum compared to 5013 mouse orthologs at day 8, and only 1504 rat and 3484 mouse orthologs at day 91. Automated dose–response modeling resulted in similar median EC{sub 50}s in the rodent duodenal and jejunal mucosae. Comparative examination of differentially expressed genes also identified divergently regulated orthologs. Comparable numbers of differentially expressed genes were observed at equivalent Cr concentrations (μg Cr/g duodenum). However, mice accumulated higher Cr levels than rats at ≥ 170 mg/L SDD, resulting in a ∼ 2-fold increase in the number of differentially expressed genes. These qualitative and quantitative differences in differential gene expression, which correlate with differences in tissue dose, likely contribute to the disparate intestinal tumor outcomes. -- Highlights: ► Cr(VI) elicits dose-dependent changes in gene expression in rat intestine. ► Cr(VI) elicits less differential gene expression in rats compared to mice. ► Cr(VI) gene expression can be phenotypically anchored to intestinal changes. ► Species-specific and divergent changes are consistent with species-specific tumors.« less
SU-E-T-757: TMRs Calculated From PDDs Versus the Direct Measurements for Small Field SRS Cones
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, H; Zhong, H; Song, K
2015-06-15
Purpose: To investigate the variation of TMR for SRS cones obtained by TMR scanning, calculation from PDDs, and point measurements. The obtained TMRs were also compared to the representative data from the vendor. Methods: TMRs for conical cones of 4, 5, 7.5, 10, 12.5, 15, and 17.5 mm diameter (jaws set to 5×5 cm) were obtained for 6X FFF and 10X FFF energies on a Varian Edge linac. TMR scanning was performed with a Sun Nuclear 3D scanner and Edge detector at 100 cm SDD. TMR point measurements were measured with a Wellhofer tank and Edge detector, at multiple depthsmore » from 0.5 to 20 cm and 100 cm SDD. PDDs for converting to TMR were scanned with a Wellhofer system and SFD detector. The formalism of converting PDD to TMR, given in Khan’s book (4th Edition, p.161) was applied. Sp values at dmax were obtained by measuring Scp and Sc of the cones (jaws set to 5×5 cm) using the Edge detector, and normalized to the 10×10 cm field. Results: Along the central axis beyond dmax, the RMS and maximum percent difference of TMRs obtained with different methods were as follows: (a) 1.3% (max=3.5%) for the calculated TMRs from PDDs versus direct scanning; (b) 1.2% (max=3.3%) for direct scanning versus point measurement; (c) 1.8% (max=5.1%) for the calculated versus point measurements; (d) 1.0% (max=3.6%) for direct scanning versus vendor data; (e) 1.6% (max=7.2%) for the calculated versus vendor data. Conclusion: The overall accuracy of TMRs calculated from PDDs was comparable with that of direct scanning. However, the uncertainty at depths greater than 20 cm, increased up to 5% when compared to point measurements. This issue must be considered when developing a beam model for small field SRS planning using cones.« less
NASA Astrophysics Data System (ADS)
Newbury, Dale E.; Ritchie, Nicholas W. M.
2013-05-01
The typical strategy for analysis of a microscopic particle by scanning electron microscopy/energy dispersive spectrometry x-ray microanalysis (SEM/EDS) is to use a fixed beam placed at the particle center or to continuously overscan to gather an "averaged" x-ray spectrum. While useful, such strategies inevitably concede any possibility of recognizing microstructure within the particle, and such fine scale structure is often critical for understanding the origins, behavior, and fate of particles. Elemental imaging by x-ray mapping has been a mainstay of SEM/EDS analytical practice for many years, but the time penalty associated with mapping with older EDS technology has discouraged its general use and reserved it more for detailed studies that justified the time investment. The emergence of the high throughput, high peak stability silicon drift detector (SDD-EDS) has enabled a more effective particle mapping strategy: "flash" x-ray spectrum image maps can now be recorded in seconds that capture the spatial distribution of major (concentration, C > 0.1 mass fraction) and minor (0.01 <= C <= 0.1) constituents. New SEM/SDD-EDS instrument configurations feature multiple SDDs that view the specimen from widely spaced azimuthal angles. Multiple, simultaneous measurements from different angles enable x-ray spectrometry and mapping that can minimize the strong geometric effects of particles. The NIST DTSA-II software engine is a powerful aid for quantitatively analyzing EDS spectra measured individually as well as for mapping information (available free for Java platforms at: http://www.cstl.nist.gov/div837/837.02/epq/dtsa2/index.html).
Newbury, Dale E; Ritchie, Nicholas W M
2011-01-01
The high throughput of the silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS) enables X-ray spectrum imaging (XSI) in the scanning electron microscope to be performed in frame times of 10-100 s, the typical time needed to record a high-quality backscattered electron (BSE) image. These short-duration XSIs can reveal all elements, except H, He, and Li, present as major constituents, defined as 0.1 mass fraction (10 wt%) or higher, as well as minor constituents in the range 0.01-0.1 mass fraction, depending on the particular composition and possible interferences. Although BSEs have a greater abundance by a factor of 100 compared with characteristic X-rays, the strong compositional contrast in element-specific X-ray maps enables XSI mapping to compete with BSE imaging to reveal compositional features. Differences in the fraction of the interaction volume sampled by the BSE and X-ray signals lead to more delocalization of the X-ray signal at abrupt compositional boundaries, resulting in poorer spatial resolution. Improved resolution in X-ray elemental maps occurs for the case of a small feature composed of intermediate to high atomic number elements embedded in a matrix of lower atomic number elements. XSI imaging strongly complements BSE imaging, and the SDD-EDS technology enables an efficient combined BSE-XSI measurement strategy that maximizes the compositional information. If 10 s or more are available for the measurement of an area of interest, the analyst should always record the combined BSE-XSI information to gain the advantages of both measures of compositional contrast. Copyright © 2011 Wiley Periodicals, Inc.
DOT National Transportation Integrated Search
2014-04-01
This report documents the System Design Document (SDD) for the prototype development and demonstration of the Response, Emergency Staging, Communications, Uniform Management, and Evacuation (R.E.S.C.U.M.E.) application bundle, with a focus on the Inc...
Honnavar, Prasanna; Prasad, Gandham S.; Ghosh, Anup; Dogra, Sunil; Handa, Sanjeev
2016-01-01
The majority of species within the genus Malassezia are lipophilic yeasts that colonize the skin of warm-blooded animals. Two species, Malassezia globosa and Malassezia restricta, are implicated in the causation of seborrheic dermatitis/dandruff (SD/D). During our survey of SD/D cases, we isolated several species of Malassezia and noticed vast variations within a few lipid-dependent species. Variations observed in the phenotypic characteristics (colony morphology, absence of catalase activity, growth at 37°C, and precipitation surrounding wells containing Tween 20 or Cremophor EL) suggested the possible presence of a novel species. Sequence divergence observed in the internal transcribed spacer (ITS) region, the D1/D2 domain, and the intergenic spacer 1 (IGS1) region of rDNA and the TEF1 gene, PCR-restriction fragment length polymorphism (RFLP) analysis of the ITS2 region, and fluorescent amplified fragment length polymorphism analysis support the existence of a novel species. Based on phenotypic and molecular characterization of these strains, we propose a new species, namely, M. arunalokei sp. nov., and we designate NCCPF 127130 (= MTCC 12054 = CBS 13387) as the type strain. PMID:27147721
Honnavar, Prasanna; Prasad, Gandham S; Ghosh, Anup; Dogra, Sunil; Handa, Sanjeev; Rudramurthy, Shivaprakash M
2016-07-01
The majority of species within the genus Malassezia are lipophilic yeasts that colonize the skin of warm-blooded animals. Two species, Malassezia globosa and Malassezia restricta, are implicated in the causation of seborrheic dermatitis/dandruff (SD/D). During our survey of SD/D cases, we isolated several species of Malassezia and noticed vast variations within a few lipid-dependent species. Variations observed in the phenotypic characteristics (colony morphology, absence of catalase activity, growth at 37°C, and precipitation surrounding wells containing Tween 20 or Cremophor EL) suggested the possible presence of a novel species. Sequence divergence observed in the internal transcribed spacer (ITS) region, the D1/D2 domain, and the intergenic spacer 1 (IGS1) region of rDNA and the TEF1 gene, PCR-restriction fragment length polymorphism (RFLP) analysis of the ITS2 region, and fluorescent amplified fragment length polymorphism analysis support the existence of a novel species. Based on phenotypic and molecular characterization of these strains, we propose a new species, namely, M. arunalokei sp. nov., and we designate NCCPF 127130 (= MTCC 12054 = CBS 13387) as the type strain. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Information Management Platform for Data Analytics and Aggregation (IMPALA) System Design Document
NASA Technical Reports Server (NTRS)
Carnell, Andrew; Akinyelu, Akinyele
2016-01-01
The System Design document tracks the design activities that are performed to guide the integration, installation, verification, and acceptance testing of the IMPALA Platform. The inputs to the design document are derived from the activities recorded in Tasks 1 through 6 of the Statement of Work (SOW), with the proposed technical solution being the completion of Phase 1-A. With the documentation of the architecture of the IMPALA Platform and the installation steps taken, the SDD will be a living document, capturing the details about capability enhancements and system improvements to the IMPALA Platform to provide users in development of accurate and precise analytical models. The IMPALA Platform infrastructure team, data architecture team, system integration team, security management team, project manager, NASA data scientists and users are the intended audience of this document. The IMPALA Platform is an assembly of commercial-off-the-shelf (COTS) products installed on an Apache-Hadoop platform. User interface details for the COTS products will be sourced from the COTS tools vendor documentation. The SDD is a focused explanation of the inputs, design steps, and projected outcomes of every design activity for the IMPALA Platform through installation and validation.
Abraham, Anuji; Crull, George
2014-10-06
A simple and robust method for obtaining fluorine-carbon proximities was established using a (19)F-(13)C heteronuclear correlation (HETCOR) two-dimensional (2D) solid-state nuclear magnetic resonance (ssNMR) experiment under magic-angle spinning (MAS). The method was applied to study a crystalline active pharmaceutical ingredient (API), avagacestat, containing two types of fluorine atoms and its API-polymer composite drug product. These results provide insight into the molecular structure, aid with assigning the carbon resonances, and probe API-polymer proximities in amorphous spray dried dispersions (SDD). This method has an advantage over the commonly used (1)H-(13)C HETCOR because of the large chemical shift dispersion in the fluorine dimension. In the present study, fluorine-carbon distances up to 8 Å were probed, giving insight into the API structure, crystal packing, and assignments. Most importantly, the study demonstrates a method for probing an intimate molecular level contact between an amorphous API and a polymer in an SDD, giving insights into molecular association and understanding of the role of the polymer in API stability (such as recrystallization, degradation, etc.) in such novel composite drug products.
Silicon drift detectors with on-chip electronics for x-ray spectroscopy.
Fiorini, C; Longoni, A; Hartmann, R; Lechner, P; Strüder, L
1997-01-01
The silicon drift detector (SDD) is a semiconductor device based on high resistivity silicon fully depleted through junctions implanted on both sides of the semiconductor wafer. The electrons generated by the ionizing radiation are driven by means of a suitable electric field from the point of interaction toward a collecting anode of small capacitance, independent of the active area of the detector. A suitably designed front-end JFET has been directly integrated on the detector chip close to the anode region, in order to obtain a nearly ideal capacitive matching between detector and transistor and to minimize the stray capacitances of the connections. This feature allows it to reach high energy resolution also at high count rates and near room temperature. The present work describes the structure and the performance of SDDs specially designed for high resolution spectroscopy with soft x rays at high detection rate. Experimental results of SDDs used in spectroscopy applications are also reported.
NASA Astrophysics Data System (ADS)
Swanson, C.; Jandovitz, P.; Cohen, S. A.
2017-10-01
Knowledge of the full x-ray energy distribution function (XEDF) emitted from a plasma over a large dynamic range of energies can yield valuable insights about the electron energy distribution function (EEDF) of that plasma and the dynamic processes that create them. X-ray pulse height detectors such as Amptek's X-123 Fast SDD with Silicon Nitride window can detect x-rays in the range of 200eV to 100s of keV. However, extracting EEDF from this measurement requires precise knowledge of the detector's response function. This response function, including the energy scale calibration, the window transmission function, and the resolution function, can be measured directly. We describe measurements of this function from x-rays from a mono-energetic electron beam in a purpose-built gas-target x-ray tube. Large-Z effects such as line radiation, nuclear charge screening, and polarizational Bremsstrahlung are discussed.
NASA Astrophysics Data System (ADS)
Yang, Yi-fan; Cui, Zhong-hua; Ding, Yi-hong
2014-06-01
Compounds with high electron affinity, i.e. superhalogens, have continued to attract chemists' attention, due to their potential importance in fundamental chemistry and materials science. It has now proven very effective to build up novel superhalogens with multi-positively charged centres, which are usually called 'hyperhalogens'. Herein, using AuF4- and PO3 as the model building blocks, we made the first attempt to design the Au,P-based hyperhalogen anions AuF4-n(PO3)n- (n = 1-4) at the B3LYP/6-311+G(d)&SDD and CCSD(T)/6-311+G(d)&SDD (single-point) levels (6-311+G(d) for O, F, P and SDD for Au). Notably, for all the considered Au,P systems, the ground state bears a dioxo-bonded structure with n ≤ 3, which is significantly more stable than the usually presumed mono-oxo-bonded one. Moreover, the clustering of the -PO3 moieties becomes energetically favoured for n ≥ 3. The ground states of AuP4O120,- are the first reported cage-like oxide hyperhalogens. Thus, the -PO3 moiety cannot be retained during the 'bottom-up' assembly. The vertical detachment energy (VDE) value of the most stable AuF4-n(PO3)n- (n = 1-4) ranges from 7.16 to 8.20 eV, higher than the VDE values of the corresponding building blocks AuF4- (7.08 eV) and PO3- (4.69 eV). The adiabatic detachment energy values of these four hyperhalogens exceed 6.00 eV. Possible generation routes for AuF4-n(PO3)n- (n = 1-4) were discussed. The presently designed oxyfluorides not only enriches the family of hyperhalogens, but also demonstrates the great importance of considering the structural transformation during the superhalogen → hyperhalogen design such as for the present Au-P based systems.
APXS on board Chandrayaan-2 Rover
NASA Astrophysics Data System (ADS)
Shanmugam, M.; Sripada, V. S. Murty; Acharya, Y. B.; Goyal, S. K.
2012-07-01
Alpha Particle X-ray Spectrometer (APXS) is a well proven instrument for quantitative in situ elemental analysis of the planetary surfaces and has been successfully employed for Mars surface exploration. Chandrayaan-2, ISRO's second lunar mission having an Orbiter, Lander and Rover has provided an opportunity to explore the lunar surface with superior detectors such as Silicon Drift Detector (SDD) with energy resolution of about 150eV @ 5.9keV. The objective of the APXS instrument is to analyse several soil/rock samples along the rover traverse for the major elements with characteristic X-rays in 1 to 25keV range. The working principle of APXS involves measuring the intensity of characteristic X-rays emitted from the sample due to Alpha Particle Induced X-ray Emission (PIXE) and X-ray florescence (XRF) processes using suitable radioactive sources, allowing the determination of elements from Na to Br, spanning the energy range of 0.9 to 16keV. For this experiment ^{244}Cm radioactive source has been chosen which emits both Alpha particles (5.8MeV) and X-rays (14.1keV, 18keV). APXS uses six Alpha sources, each about 5mCi activity. Unlike Mars, lunar environment poses additional challenges due to the regolith and extreme surface temperature changes, to operate the APXS. Our APXS instrument consists of two packages namely APXS sensor head and APXS signal electronics. The sensor head assembly contains SDD, six alpha sources and front end electronic circuits such as preamplifier and shaper circuits and will be mounted on a robotic arm which on command brings the sensor head close to the lunar surface at a height of 35±10mm. SDD module to be used in the experiment has 30mm ^{2} active detector area with in-built peltier cooler and heat sink to maintain the detector at about -35°C. The detector is covered with 8 micron thick Be window which results in the low energy threshold of about 1keV. The size of the APXS sensor head is 70x70x70mm ^{3} (approx). APXS signal electronics consists of a PCB having digital, power and rover interface electronics circuits, which are housed inside the Warm Electronics Box (WEB) mounted under the rover chassis where the temperature is maintained between -50°C to +70°C. Presently, we have completed the design verification model of the APXS payload and engineering model of the payload is in progress. The developed system has been tested using laboratory X-ray sources and observed an energy resolution of about 150eV at 5.9keV when the detector is cooled to -35°C. We also carried out the detection of X-ray fluorescence for some of the USGS standards for a fixed geometry of detector, source and sample, using ^{55}Fe and ^{241}Am X-ray sources. It is shown that the count rate of a given peak varies linearly with the concentration of the corresponding element. The detailed developments and results will be discussed at the conference.
Plutonium Immobilization Project System Design Description for Can Loading System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kriikku, E.
2001-02-15
The purpose of this System Design Description (SDD) is to specify the system and component functions and requirements for the Can Loading System and provide a complete description of the system (design features, boundaries, and interfaces), principles of operation (including upsets and recovery), and the system maintenance approach. The Plutonium Immobilization Project (PIP) will immobilize up to 13 metric tons (MT) of U.S. surplus weapons usable plutonium materials.
1991-07-03
required changes to this matrix. CMOS PMO ACCEPTS COMMENT: YES [ ] NO [ ] ERCI ACCEPTS COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN...this appendix should be updated to include all necessary changes. CMOS PMO ACCEPTS COMMENT: YES [ ] NO [ ] ERCI ACCEPTS COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION...ERCI ACCEPTS COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ ] CLOSED [ ] ORIGINATOR CONTROL NUMBER: SDD3-0004 PROGRAM OFFICE
46th Annual Gun and Missile Systems Conference and Exhibition. Volume 2. Wednesday
2011-09-01
military/systems/munitions/images/ Page 7 Designing for Operational Challenges Gun hardening – Multiple charges • Angular acceleration variation ...The industrial base overestimated readiness at SDD start – Analysis/models were naive • Impulsive loads — pressure variation — SOM under impulse...Manufacture and Producibility Branch, US Army Armament Research, Development and Engineering Center • Alan Sweet and William Goldberg , Packaging Division
Velez-Valle, Enid M; Echeverria, Sandra; Santorelli, Melissa
2016-09-01
On October 29, 2012, Hurricane Sandy made landfall in New Jersey, causing major power outages, flooded roads, and disruption of public transportation. Individuals diagnosed with diabetes may be especially vulnerable to natural disasters because of limited access to medications or use of glucose monitoring devices. We examined changes in emergency room visits (ERVs) for type II diabetes mellitus potentially associated with Hurricane Sandy in New Jersey. Data analyzed in 2014 included ERVs to general acute care hospitals in New Jersey among residents of three counties with a primary or secondary type II diabetes diagnosis (PDD or SDD) in 2011–2012. Compared to the previous year, results showed an 84% increased rate of PDD ERVs during the week of Hurricane Sandy, after adjusting for age and sex (rate ratio (RR) = 1.84, 95% confidence interval (CI) 1.12, 3.04). Results were nonsignificant for SDD (RR = 0.94, 95% CI 0.83, 1.08). Spatial analysis showed the increase in visits was not consistently associated with flood zone areas. We observed substantial increases in ERVs for primary type II diabetes diagnoses associated with Hurricane Sandy in New Jersey. Future public health preparedness efforts during storms should include planning for the healthcare needs of populations living with diabetes.
Wongsomboon, Val; Robles, Elias
2017-10-01
The value of safe sex may be discounted based on contextual factors associated with an opportunity for sex. College students in a within-subjects study selected hypothetical sexual partners from a set of pictures and classified them based on attractiveness and estimated chance of having an sexually transmitted infection (STI). In the Sexual Delay Discounting (SDD) task, participants rated their likelihood (0-100 %) of waiting for some period of time (e.g., 3 h) to have protected sex with their selected partners, when they could have immediate sex without protection. In the Sexual Probability Discounting (SPD) task, participants rated their likelihood of having protected sex if the opportunity was uncertain (e.g., 50 %), when they could have unprotected sex for sure (100 %). All participants included in the final analyses were aware of and had a positive attitude towards protection against STIs as they were likely to have immediate (or certain) protected sex. Results from 432 delay data in the SDD task and 488 probability data in the SPD task showed that participants' preference for safe sex systematically decreased as the delay to and odds against having safe sex increased. However, this preference was altered by the participants' perception of their partner's attractiveness and STI risk.
The sunspot databases of the Debrecen Observatory
NASA Astrophysics Data System (ADS)
Baranyi, Tünde; Gyori, Lajos; Ludmány, András
2015-08-01
We present the sunspot data bases and online tools available in the Debrecen Heliophysical Observatory: the DPD (Debrecen Photoheliographic Data, 1974 -), the SDD (SOHO/MDI-Debrecen Data, 1996-2010), the HMIDD (SDO/HMI-Debrecen Data, HMIDD, 2010-), the revised version of Greenwich Photoheliographic Data (GPR, 1874-1976) presented together with the Hungarian Historical Solar Drawings (HHSD, 1872-1919). These are the most detailed and reliable documentations of the sunspot activity in the relevant time intervals. They are very useful for studying sunspot group evolution on various time scales from hours to weeks. Time-dependent differences between the available long-term sunspot databases are investigated and cross-calibration factors are determined between them. This work has received funding from the European Community's Seventh Framework Programme (FP7/2012-2015) under grant agreement No. 284461 (eHEROES).
Beyond the Great Wall: gold of the silk roads and the first empire of the steppes.
Radtke, Martin; Reiche, Ina; Reinholz, Uwe; Riesemeier, Heinrich; Guerra, Maria F
2013-02-05
Fingerprinting ancient gold work requires the use of nondestructive techniques with high spatial resolution (down to 25 μm) and good detection limits (micrograms per gram level). In this work experimental setups and protocols for synchrotron radiation induced X-ray fluorescence (SRXRF) at the BAMline of the Berlin electron storage ring company for synchrotron radiation (BESSY) in Berlin for the measurement of characteristic trace elements of gold are compared considering the difficulties, shown in previous works, connected to the quantification of Pt. The best experimental conditions and calculation methods were achieved by using an excitation energy of 11.58 keV, a silicon drift chamber detector (SDD) detector, and pure element reference standards. A detection limit of 3 μg/g has been reached. This newly developed method was successfully applied to provenancing the Xiongnu gold from the Gol Mod necropolis, excavated under the aegis of the United Nations Educational, Scientific and Cultural Organization (UNESCO). The composition of the base alloys and the presence of Pt and Sn showed that, contrary to what is expected, the gold foils from the first powerful empire of the steppes along the Great Wall were produced with alluvial gold from local placer deposits located in Zaamar, Boroo, and in the Selenga River.
Effects of improper source coupling in frequency-domain near-infrared spectroscopy
NASA Astrophysics Data System (ADS)
Noponen, T. E. J.; Kotilahti, K.; Nissilä, I.; Kajava, T.; Meriläinen, P. T.
2010-05-01
Currently, there is no widely used method to assess the reliability of contact between optodes and tissue in near-infrared spectroscopy (NIRS). In this study we observe a high linear dependence (R2 ~ 0.99) of the logarithmic modulation amplitude (ln(IAC)), average intensity (ln(IDC)) and phase (phi) on the source-detector distance (SDD) ranging from ~20 to 50 mm on human forehead measurements. The regression of phi is clearly reduced in measurements where light leakage occurs, mainly due to insufficient contact between the source optode and tissue. Utilizing this observation, a novel criterion to detect light leakage is developed. The criterion is applied to study the reliability of hemodynamic responses measured on the human forehead when breathing carbon dioxide-enriched air and during hyperventilation. The contrast of the signals is significantly lower in measurements which were adversely affected by light leakage. Furthermore, such unreliable signals at SDDs >= 50 mm correlate significantly (for \\rm [HbO_2] p < 0.01 and for [HbR] p < 0.001) better with the signals measured at SDDs < 20 mm. Using this method, poor contact between the source optode and tissue can be detected and corrected before the actual measurement, which enables us to avoid the acquisition of low contrast cortical signals.
NASA Astrophysics Data System (ADS)
Yang, Yue; Gao, Hongwei
2012-04-01
Serotonin (5-hydroxytryptamine, 5-HT) is a monoamine neurotransmitter which plays an important role in treating acute or clinical stress. The comparative performance of different density functional theory (DFT) methods at various basis sets in predicting the molecular structure and vibration spectra of serotonin was reported. The calculation results of different methods including mPW1PW91, HCTH, SVWN, PBEPBE, B3PW91 and B3LYP with various basis sets including LANL2DZ, SDD, LANL2MB, 6-31G, 6-311++G and 6-311+G* were compared with the experimental data. It is remarkable that the SVWN/6-311++G and SVWN/6-311+G* levels afford the best quality to predict the structure of serotonin. The results also indicate that PBEPBE/LANL2DZ level show better performance in the vibration spectra prediction of serotonin than other DFT methods.
Hu, Qian-Nan; Deng, Zhe; Hu, Huanan; Cao, Dong-Sheng; Liang, Yi-Zeng
2011-09-01
Biochemical reactions play a key role to help sustain life and allow cells to grow. RxnFinder was developed to search biochemical reactions from KEGG reaction database using three search criteria: molecular structures, molecular fragments and reaction similarity. RxnFinder is helpful to get reference reactions for biosynthesis and xenobiotics metabolism. RxnFinder is freely available via: http://sdd.whu.edu.cn/rxnfinder. qnhu@whu.edu.cn.
Material Life Cycle Analysis for the Reduction of Waste Generation at Military Installations
2017-02-01
avoid the fossil fuel consumption and land degradation associated with transporting those materials to a landfill. Eco-LCA can also be used to calcu...Recycling Program RMRC Recycled Materials Resource Center SAR Same As Report SDD Sustainable Design and Development SF Standard Form SME Subject...Agency WWII World War II REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information
Cargo Movement Operations System (CMOS) Final Software User’s Manual
1990-12-20
CMOS PMO ACCEPTS COMMENT: YES [ ] NO [ ] ERCI ACCEPTS COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION: ACCEPT [ ] REJECT [ I COMMENT STATUS: OPEN...is correct. CMOS PMO ACCEPTS COMMENT: YES [ ] NO [ ] ERCI ACCEPTS CO1MENT: YES [ ] NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ ] CLOSED...RATIONALE: .."DA001041" is in the SUM but not in the SDD. CMOS PMO ACCEPTS COMMENT: YES [ ] NO [ ERCI ACCEPTS COMMENT: YES [ ] NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ ] CLOSED [
Performance of a Commercial Silicon Drift Detector for X-ray Microanalysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenik, Edward A
2008-01-01
Silicon drift detectors (SDDs) are rapidly becoming the energy dispersive spectrometer of choice especially for scanning electron microscopy applications. The complementary features of large active areas (i.e., collection angle) and high count rate capability of these detector contribute to their popularity, as well as the absence of liquid nitrogen cooling of the detector. The performance of an EDAX Apollo 40 SDD on a JEOL 6500F SEM will be discussed.
2009-08-24
interests are strategic resource management, strategic control, and corporate financial reporting. Joseph G. San Miguel Professor Graduate School of...Officer PM – Program Manager SAIC – Science Applications International Corporation SAP – Systems Applications and Products SDD – System Development and...the award of the multi-billion dollar FCS program management contract to the Boeing Company and Science Applications International Corporation (SAIC
NASA Astrophysics Data System (ADS)
Maderitsch, A.; Smolek, S.; Wobrauschek, P.; Streli, C.; Takman, P.
2014-09-01
Total reflection X-ray spectroscopy (TXRF) is a powerful analytical technique for qualitative and quantitative analysis of trace and ultratrace elements in a sample with lower limits of detection (LLDs) of pg/g to ng/g in concentration and absolute high fg levels are attainable. Several X-ray sources, from low power (few W), 18 kW rotating anodes to synchrotron radiation, are in use for the excitation and lead accordingly to their photon flux delivered on the sample the detection limits specified. Not only the power, but also the brilliance and focal shape are of importance for TXRF. A microfocus of 50-100 μm spot size or the line focus of diffraction tubes is best suited. Excillum developed a new approach in the design of a source: the liquid metal jet anode. In this paper the results achieved with this source are described. A versatile TXRF spectrometer with vacuum chamber designed at Atominstitut was used for the experiments. A multilayer monochromator selecting the intensive Ga-Kα radiation was taken and the beam was collimated by 50 μm slits. Excellent results regarding geometric beam stability, high fluorescence intensities and low background were achieved leading to detection limits in the high fg range for Ni. A 100 mm2 silicon drift detector (SDD) collimated to 80 mm2 was used to collect the fluorescence radiation. The results from measurements on single element samples are presented.
Counting-loss correction for X-ray spectroscopy using unit impulse pulse shaping.
Hong, Xu; Zhou, Jianbin; Ni, Shijun; Ma, Yingjie; Yao, Jianfeng; Zhou, Wei; Liu, Yi; Wang, Min
2018-03-01
High-precision measurement of X-ray spectra is affected by the statistical fluctuation of the X-ray beam under low-counting-rate conditions. It is also limited by counting loss resulting from the dead-time of the system and pile-up pulse effects, especially in a high-counting-rate environment. In this paper a detection system based on a FAST-SDD detector and a new kind of unit impulse pulse-shaping method is presented, for counting-loss correction in X-ray spectroscopy. The unit impulse pulse-shaping method is evolved by inverse deviation of the pulse from a reset-type preamplifier and a C-R shaper. It is applied to obtain the true incoming rate of the system based on a general fast-slow channel processing model. The pulses in the fast channel are shaped to unit impulse pulse shape which possesses small width and no undershoot. The counting rate in the fast channel is corrected by evaluating the dead-time of the fast channel before it is used to correct the counting loss in the slow channel.
Proton Induced X-Ray Emission (PIXE): Determining the Concentration of Samples
NASA Astrophysics Data System (ADS)
McCarthy, Mallory; Rodriguez Manso, Alis; Pajouhafsar, Yasmin; J Yennello, Sherry
2017-09-01
We used Proton Induced X-ray Emission (PIXE) as an analysis technique to determine the composition of samples, in particular, the elemental constituents and the concentrations. Each of the samples are bombarded with protons, which in result displaces a lower level electron and causes a higher level electron to fall into its place. This displacement produces characteristic x-rays that are `fingerprints' for each element. The protons supplied for the bombardment are produced and accelerated by the K150 proton beam in the Cyclotron Institute at Texas A&M University. The products are detected by three x-ray detectors: XR-100CR Si-PIN, XR-100SDD, and XR-100T CdTe. The peaks of the spectrum are analyzed using a software analysis tool, GUPIXWIN, to determine the concentration of the known elements of each particular sample. The goals of this work are to test run the Proton Induced X-Ray Emission experimental set up at Texas A&M University (TAMU) and to determine the concentration of thin films containing KBr given by the TAMU Chemical Engineering Department.
Samuel, Oluwarotimi Williams; Geng, Yanjuan; Li, Xiangxin; Li, Guanglin
2017-10-28
To control multiple degrees of freedom (MDoF) upper limb prostheses, pattern recognition (PR) of electromyogram (EMG) signals has been successfully applied. This technique requires amputees to provide sufficient EMG signals to decode their limb movement intentions (LMIs). However, amputees with neuromuscular disorder/high level amputation often cannot provide sufficient EMG control signals, and thus the applicability of the EMG-PR technique is limited especially to this category of amputees. As an alternative approach, electroencephalograph (EEG) signals recorded non-invasively from the brain have been utilized to decode the LMIs of humans. However, most of the existing EEG based limb movement decoding methods primarily focus on identifying limited classes of upper limb movements. In addition, investigation on EEG feature extraction methods for the decoding of multiple classes of LMIs has rarely been considered. Therefore, 32 EEG feature extraction methods (including 12 spectral domain descriptors (SDDs) and 20 time domain descriptors (TDDs)) were used to decode multiple classes of motor imagery patterns associated with different upper limb movements based on 64-channel EEG recordings. From the obtained experimental results, the best individual TDD achieved an accuracy of 67.05 ± 3.12% as against 87.03 ± 2.26% for the best SDD. By applying a linear feature combination technique, an optimal set of combined TDDs recorded an average accuracy of 90.68% while that of the SDDs achieved an accuracy of 99.55% which were significantly higher than those of the individual TDD and SDD at p < 0.05. Our findings suggest that optimal feature set combination would yield a relatively high decoding accuracy that may improve the clinical robustness of MDoF neuroprosthesis. The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.
F-35 Joint Strike Fighter (JSF) Program
2012-02-16
Operational Test and Evaluation ( IOT &E), a subset of SDD.61 The eight partner countries are expected to purchase hundreds of F-35s, with the United...Netherlands have agreed to participate in the IOT &E program. UK, the senior F-35 partner, will have the strongest participation in the IOT &E phase...testing. (Telephone conversation with OSD/AT&L, October 3, 2007.) Other partner nations are still weighing their option to participate in the IOT &E
1981-01-14
wet-bulb temperature depression versus dry -bulb temperature, means and standard deviations of d-j-bulb, wet-bulb (over) SDD, 1473 UNCLASS IF I ED FC...distribution tables Dry -bulb temperature versud wet-bulb temperature Cumulative percentage frequency of distribution tables 20. and dew point...PART 5 PRECIPITATION PSYCHROMETRIC.DRY VS WET BULB SNOWFALL MEAN & STO 0EV SNOW EPTH DRY BULB, WET BULB, &DEW POINtI RELATIVE HUMIDITY PARTC SURFACE
Newbury, Dale E; Ritchie, Nicholas W M
2015-10-01
A scanning electron microscope with a silicon drift detector energy-dispersive X-ray spectrometer (SEM/SDD-EDS) was used to analyze materials containing the low atomic number elements B, C, N, O, and F achieving a high degree of accuracy. Nearly all results fell well within an uncertainty envelope of ±5% relative (where relative uncertainty (%)=[(measured-ideal)/ideal]×100%). Quantification was performed with the standards-based "k-ratio" method with matrix corrections calculated based on the Pouchou and Pichoir expression for the ionization depth distribution function, as implemented in the NIST DTSA-II EDS software platform. The analytical strategy that was followed involved collection of high count (>2.5 million counts from 100 eV to the incident beam energy) spectra measured with a conservative input count rate that restricted the deadtime to ~10% to minimize coincidence effects. Standards employed included pure elements and simple compounds. A 10 keV beam was employed to excite the K- and L-shell X-rays of intermediate and high atomic number elements with excitation energies above 3 keV, e.g., the Fe K-family, while a 5 keV beam was used for analyses of elements with excitation energies below 3 keV, e.g., the Mo L-family.
Meteor activity from 2001XQ on 2-3 December 2016?
NASA Astrophysics Data System (ADS)
Roggemans, Paul
2016-04-01
The minor shower 66 Draconid (541 SDD) which was discovered by the Croatian Meteor Network has a mean orbit based on 43 meteors, similar to the orbit of 2001 XD. The asteroid 2001 XD has an orbit typical for Jupiter family comets and therefore may be a dormant comet. The shower activity ranges from November 23 until December 21. All meteor observers are encouraged to pay attention to any possible meteors from this source, although no outburst or any anything spectacular has to be expected.
Consolidated Cab Display (CCD) System, Project Planning Document (PPD),
1981-02-01
1980 1981 I 2 3 4 5 6 7 8 9 10 1112 1 2 3 4 5 6 7 8 9 1011112 1 2 31 12. Software Documentation a. Overall Computer Program Description ( OCPD ) b...Approve OCPD c. Computer Program Functional Specifications (CPFS) d. Data Base Table Design Specification (DBTDS) e. Software Interface Control Document...Parts List Master Pattern and Plan View Reproducible Drawings Instruction Book Training Aids/Materials b. Software: OCPD CPFS SI CD PDS DBTDS SDD
1991-09-05
NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ ] CLOSED [ 3 ... ... .. . ....... ... .. ............ ... . . . . . . . u m ORIGINATOR CONTROL NUMBER: SDD-0002 PROGRAM OFFICE CONTROL NUMBER: DATA ITEM DISCREPANCY WORKSHEET CDRL NUMBER: DCO0-0005d DATE: 09/05/91 ORIGINATOR NAME: Vivian L. Martin OFFICE SYMBOL: SAIC TELEPHONE NUMBER: 271-2999 SUBSTANTIVE: x EDITORIAL: PAGE NUMBER: CUlAO025-3 PARA NUMBER: c. COMMENT OR RECOMMENDED CHANGE: Provide the input, output, and local data elements for this CSU. RATIONALE: Paragraph c. states that data
Theoretical survey of the reaction between osmium and acetaldehyde
NASA Astrophysics Data System (ADS)
Dai, Guo-Liang; Wang, Chuan-Feng
2012-05-01
The mechanism of the reaction of osmium atom with acetaldehyde has been investigated with a DFT approach. All the stationary points are determined at the UB3LYP/ sdd/6-311++G** level of the theory. Both ground and excited state potential energy surfaces are investigated in detail. The present results show that the title reaction start with the formation of a CH3CHO-metal complex followed by C-C, aldehyde C-H, C-O, and methyl C-H activation. These reactions can lead to four different products (HOsCH3 + CO, OsCO + CH4, OsCOCH3 + H, and OsO + C2H4). The minimum energy reaction path is found to involve the spin inversion in the initial reaction step. This potential energy curve-crossing dramatically affects reaction exothermic. The present results may be helpful in understanding the mechanism of the title reaction and further experimental investigation of the reaction.
Colosi, Ioana A; Faure, Odile; Dessaigne, Bérangére; Bourdon, Cécile; Lebeau, Bernadette; Colosi, Horaţiu A; Pelloux, Hervé
2012-05-01
We compared the E-test method to that of the Neo-Sensitabs tablet diffusion assay for evaluating the in vitro susceptibility of 100 clinical isolates of filamentous fungi (Aspergillus spp., Fusarium spp., Scedosporium spp., zygomycetes and other molds) to amphotericin B, itraconazole, voriconazole, caspofungin, and posaconazole. We determined the categorical agreement level between E-test minimum inhibitory concentrations (MIC) and tablet end-points, as opposed to the following disagreement parameters: very major error - resistant parameter (R) in E-test and susceptible (S) in tablet; major error - S by E-test and R by tablet; minor error - shifts between S and susceptible dose-dependent (S-DD) or S-DD and R. We also performed linear regression analyses and computed Pearson's correlation coefficients (R values) between the log transforms of MICs and the inhibition zone diameters of the five studied antifungal agents. For itraconazole we obtained 97% categorical agreement and R = -0.727. Categorical agreement for caspofungin and voriconazole was 96% and R =-0.821 and R = -0.789, respectively. For posaconazole the categorical agreement was 94% and R =-0.743. Amphotericin B exhibited a lower degree of agreement (76%, R = -0.672), especially in studies of Aspergillus spp. Our results suggest a potential value of the Neo-Sensitabs assay for in vitro susceptibility testing of molds to itraconazole, voriconazole, caspofungin and posaconazole, while amphotericin B exhibited an overall lower degree of agreement.
Ogata, Fumihiko; Tominaga, Hisato; Kangawa, Moe; Inoue, Kenji; Kawasaki, Naohito
2012-01-01
This study investigates the activated carbon (AC) treatment and ozone oxidation of the sulfa drugs--sulfamethoxazole (SMX), sulfamonomethoxine (SMM), sulfadimidine (SDD), and sulfadimethoxine (SDM)--in aqueous solution systems. Three AC samples were prepared from Shirasagi (AC1 and AC2) and coal (AC3), and the surface functional groups, solution pH, specific surface areas, pore volumes, and morphologies of the three samples were evaluated. The specific surface areas were in the following order: AC1 (1391 m²/g) > AC2 (1053 m²/g) > AC3 (807 m²/g). The pore volume and mean pore diameter of AC3 were greater than those of AC1 and AC2. The concentration of sulfa drugs adsorbed onto the AC samples reached equilibrium within 150 h. Experimental data of the adsorption rate were fitted to a pseudo-second-order model. The amount of sulfa drugs adsorbed onto the AC samples was in the order of SDM < SMM < SDD < SMX; the mechanism of adsorption of the sulfa drugs onto the AC samples depended on the hydrophobicity of the AC surface. The adsorption isotherm data were fitted to Freundlich and Langmuir models. Ozone was generated from oxygen gas using an A-27 ozone generator, and the complete degradation of the sulfa drugs by ozone treatment at 60 mL/min was achieved within 50 min. Ozone treatment caused the structure of the sulfa drugs to decompose via ozone oxidation.
AO wavefront sensing detector developments at ESO
NASA Astrophysics Data System (ADS)
Downing, Mark; Kolb, Johann; Baade, Dietrich; Iwert, Olaf; Hubin, Norbert; Reyes, Javier; Feautrier, Philippe; Gach, Jean-Luc; Balard, Philippe; Guillaume, Christian; Stadler, Eric; Magnard, Yves
2010-07-01
The detector is a critical component of any Adaptive Optics WaveFront Sensing (AO WFS) system. The required combination of fast frame rate, high quantum efficiency, low noise, large number and size of pixels, and low image lag can often only be met by specialized custom developments. ESO's very active WFS detector development program is described. Key test results are presented for newly developed detectors: a) the e2v L3Vision CCD220 (the fastest/lowest noise AO detector to date) to be deployed soon on 2nd Generation VLT instruments, and b) the MPI-HLL pnCCD with its superb high "red" response. The development of still more advanced laser/natural guide-star WFS detectors is critical for the feasibility of ESO's EELT. The paper outlines: a) the multi-phased development plan that will ensure detectors are available on-time for EELT first-light AO systems, b) results of design studies performed by industry during 2007 including a comparison of the most promising technologies, c) results from CMOS technology demonstrators that were built and tested over the past two years to assess and validate various technologies at the pixel level, their fulfillment of critical requirements (especially read noise and speed), and scalability to full-size. The next step will be towards Scaled-Down Demonstrators (SDD) to retire architecture and process risks. The SDD will be large enough to be used for E-ELT first-light AO WFS systems. For full operability, 30-50 full-scale devices will be needed.
Measures to prevent nosocomial infections during mechanical ventilation.
Ramirez, Paula; Bassi, Gianluigi L; Torres, Antonio
2012-02-01
Endotracheal intubation and mechanical ventilation are lifesaving measures in critically ill patients. However, these interventions increase the risk of respiratory infections, particularly ventilator-associated pneumonia (VAP). VAP constitutes a serious burden for the healthcare system and worsens the patient's outcomes; thus, several preventive strategies have been implemented. This communication reviews the current knowledge on VAP pathogenesis and the latest preventive measures. Pathogen-laden oropharyngeal secretions leak across the endotracheal tube (ETT) cuff; thus, a continuous control of the internal cuff pressure and cuffs made of polyurethane improve sealing effectiveness and associated risks of infections. Subglottic secretions aspiration prevents VAP, and the latest evidence demonstrated a reduction in the incidence of late-onset VAP. The role of ETT biofilm in the pathogenesis of VAP is not fully elucidated. Nevertheless, antimicrobial-coated ETTs have showed beneficial effects in VAP incidence. Recent experimental evidence has challenged the benefits associated with the use of the semirecumbent position; yet, these findings need to be corroborated in clinical trials. The latest results from trials testing the effects of selective digestive decontamination (SDD) showed beneficial effects on patients' outcomes, but concerns remain regarding the emergence of bacterial resistance, specifically upon digestive tract re-colonization. The use of oropharyngeal decontamination with antiseptics and the use of probiotics are potential alternatives to SDD. There is consistent evidence that strategies affecting the primary mechanisms of VAP pathogenesis efficiently reduce the occurrence of the disease. Preventive measures should be implemented grouped into bundles to improve overall efficacy.
Zhang, Yunlin; Zhou, Yongqiang; Shi, Kun; Qin, Boqiang; Yao, Xiaolong; Zhang, Yibo
2017-12-26
Chromophoric dissolved organic matter (CDOM) is an important optically active substance in aquatic environments and plays a key role in light attenuation and in the carbon, nitrogen and phosphorus biogeochemical cycles. Although the optical properties, abundance, sources, cycles, compositions and remote sensing estimations of CDOM have been widely reported in different aquatic environments, little is known about the optical properties and composition changes in CDOM along trophic gradients. Therefore, we collected 821 samples from 22 lakes along a trophic gradient (oligotrophic to eutrophic) in China from 2004 to 2015 and determined the CDOM spectral absorption and nutrient concentrations. The total nitrogen (TN), total phosphorus (TP), and chlorophyll a (Chla) concentrations and the Secchi disk depth (SDD) ranged from 0.02 to 24.75 mg/L, 0.002-3.471 mg/L, 0.03-882.66 μg/L, and 0.05-17.30 m, respectively. The trophic state index (TSI) ranged from 1.55 to 98.91 and covered different trophic states, from oligotrophic to hyper-eutrophic. The CDOM absorption coefficient at 254 nm (a(254)) ranged from 1.68 to 92.65 m -1 . Additionally, the CDOM sources and composition parameters, including the spectral slope and relative molecular size value, exhibited a substantial variability from the oligotrophic level to other trophic levels. The natural logarithm value of the CDOM absorption, lna(254), is highly linearly correlated with the TSI (r 2 = 0.92, p < .001, n = 821). Oligotrophic lakes are distinguished by a(254)<4 m -1 , and mesotrophic and eutrophic lakes are classified as 4 ≤ a(254)≤10 and a(254)>10 m -1 , respectively. The results suggested that the CDOM absorption coefficient a(254) might be a more sensitive single indicator of the trophic state than TN, TP, Chla and SDD. Therefore, we proposed a CDOM absorption coefficient and determined the threshold for defining the trophic state of a lake. Several advantages of measuring and estimating CDOM, including rapid experimental measurements, potential in situ optical sensor measurements and large-spatial-scale remote sensing estimations, make it superior to traditional TSI techniques for the rapid monitoring and assessment of lake trophic states. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Panda, Binayak
2009-01-01
Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.
C-5 Reliability Enhancement and Re-engining Program (C-5 RERP)
2015-12-01
Production Estimate Current APB Production Objective/Threshold Demonstrated Performance Current Estimate Time To Climb/Initial Level Off 837,000 lbs...RCR - Runway Condition Reading SDD - System Design and Development SL - Sea Level C-5 RERP December 2015 SAR March 23, 2016 16:10:28 UNCLASSIFIED 12...5.3 5.3 Acq O&M 0.0 0.0 -- 0.0 0.0 0.0 0.0 Total 7146.6 7135.7 N/A 6698.0 7694.1 7510.7 7066.6 Confidence Level Confidence Level of cost estimate
Gaseous 83mKr generator for KATRIN
NASA Astrophysics Data System (ADS)
Sentkerestiová, J.; Dragoun, O.; Lebeda, O.; Ryšavý, M.; Sturm, M.; Vénos, D.
2018-04-01
Monoenergetic conversion electrons from the 83mKrKr isomeric state have been proven to be useful in the calibration of several tritium neutrino mass and dark matter experiments. In this paper the design and characteristics of the gaseous 83mKrKr generator, including the 83Rb/83mKrKr source behavior in tritium, for the KATRIN experiment are presented. Using Si(Li) and silicon drift detectors (SDD) detectors, the half-life of the 83mKrKr isomeric state was measured to be 1.8620 ± 0.0019 h.
1991-07-03
NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN [ ] CLOSED ( ] ORIGINATOR CONTROL NUMBER: SDD-0003 PROGRAM OFFICE CONTROL NUMBER: DATA ITEM DISCREPANCY WORKSHEET CDRL NUMBER: A006-02 DATE: 07/03/91 ORIGINATOR NAME: Vivian L. Martin OFFICE SYMBOL: SAIC TELEPHONE NUMBER: 272-2999 SUBSTANTIVE: X EDITORIAL: PAGE NUMBER: L-1 PARA NUMBER: 10 COMMENT OR RECOMMENDED CHANGE: Explain the effect of "no longer required" or "replaced" CSUs on the Navy configuration Menu hierarchy. RATIONALE: Paragraph 10 states that the CMOS menu heirarchy is
A Comprehensive Review on Water Quality Parameters Estimation Using Remote Sensing Techniques.
Gholizadeh, Mohammad Haji; Melesse, Assefa M; Reddi, Lakshmi
2016-08-16
Remotely sensed data can reinforce the abilities of water resources researchers and decision makers to monitor waterbodies more effectively. Remote sensing techniques have been widely used to measure the qualitative parameters of waterbodies (i.e., suspended sediments, colored dissolved organic matter (CDOM), chlorophyll-a, and pollutants). A large number of different sensors on board various satellites and other platforms, such as airplanes, are currently used to measure the amount of radiation at different wavelengths reflected from the water's surface. In this review paper, various properties (spectral, spatial and temporal, etc.) of the more commonly employed spaceborne and airborne sensors are tabulated to be used as a sensor selection guide. Furthermore, this paper investigates the commonly used approaches and sensors employed in evaluating and quantifying the eleven water quality parameters. The parameters include: chlorophyll-a (chl-a), colored dissolved organic matters (CDOM), Secchi disk depth (SDD), turbidity, total suspended sediments (TSS), water temperature (WT), total phosphorus (TP), sea surface salinity (SSS), dissolved oxygen (DO), biochemical oxygen demand (BOD) and chemical oxygen demand (COD).
NASA Astrophysics Data System (ADS)
Zara, Zeenat; Iqbal, Javed; Ayub, Khurshid; Irfan, Muhammad; Mahmood, Athar; Khera, Rasheed Ahmad; Eliasson, Bertil
2017-12-01
A comparative study of UV/Visible spectra of carboline and carbazole derivatives was conducted by employing the Density Functional Theory (DFT) approach. In this study, the geometries of ground and excited states, excitation energy and absorption spectra were estimated by using seven different DFT functional; CAM-B3LYP, B3LYP, MPW1PW91, PBE, B3PW91, WB97XD and HSE06 with 6-31G basis set. Moreover, five different basis sets 3-21G, 6-31G, DGDZVP, DGTZVP and SDD were also investigated with the CAM-B3LYP and WB97XD functional to take out the best combination of functional and basis set. CAM-B3LYP/6-31G and WB97XD/DGDZVP combination were found to have closest agreement with the experimental values of β-carboline derivatives and carbazole derivatives, respectively. This study provided an insight about the electronic characteristics of the selected compounds and provided an effective tool for developing and designing the better UV absorber compounds.
A Comprehensive Review on Water Quality Parameters Estimation Using Remote Sensing Techniques
Gholizadeh, Mohammad Haji; Melesse, Assefa M.; Reddi, Lakshmi
2016-01-01
Remotely sensed data can reinforce the abilities of water resources researchers and decision makers to monitor waterbodies more effectively. Remote sensing techniques have been widely used to measure the qualitative parameters of waterbodies (i.e., suspended sediments, colored dissolved organic matter (CDOM), chlorophyll-a, and pollutants). A large number of different sensors on board various satellites and other platforms, such as airplanes, are currently used to measure the amount of radiation at different wavelengths reflected from the water’s surface. In this review paper, various properties (spectral, spatial and temporal, etc.) of the more commonly employed spaceborne and airborne sensors are tabulated to be used as a sensor selection guide. Furthermore, this paper investigates the commonly used approaches and sensors employed in evaluating and quantifying the eleven water quality parameters. The parameters include: chlorophyll-a (chl-a), colored dissolved organic matters (CDOM), Secchi disk depth (SDD), turbidity, total suspended sediments (TSS), water temperature (WT), total phosphorus (TP), sea surface salinity (SSS), dissolved oxygen (DO), biochemical oxygen demand (BOD) and chemical oxygen demand (COD). PMID:27537896
Knutson, Nels C; Schmidt, Matthew C; Belley, Matthew D; Nguyen, Ngoc B; Li, H Harold; Sajo, Erno; Price, Michael J
2017-07-01
Real-time dynamic control of the linear accelerator, couch, and imaging parameters during radiation delivery was investigated as a novel technique for acquiring tissue maximum ratio (TMR) data. TrueBeam Developer Mode (Varian Medical Systems, Palo Alto, CA, USA) was used to control the linear accelerator using the Extensible Markup Language (XML). A single XML file was used to dynamically manipulate the machine, couch, and imaging parameters during radiation delivery. A TG-51 compliant 1D water tank was placed on the treatment couch, and used to position a detector at isocenter at a depth of 24.5 cm. A depth scan was performed towards the water surface. Via XML control, the treatment couch vertical position was simultaneously lowered at the same rate, maintaining the detector position at isocenter, allowing for the collection of TMR data. To ensure the detector remained at isocenter during the delivery, the in-room camera was used to monitor the detector. Continuous kV fluoroscopic images during 10 test runs further confirmed this result. TMR data at multiple Source to Detector Distances (SDD) and scan speeds were acquired to investigate their impact on the TMR data. Percentage depth dose (PDD) scans (for conversion to TMR) along with traditional discrete TMR data were acquired as a standard for comparison. More than 99.8% of the measured points had a gamma value (1%/1 mm) < 1 when compared with discrete or PDD converted TMR data. Fluoroscopic images showed that the concurrent couch and tank movements resulted in SDD errors < 1 mm. TMRs acquired at SDDs of 99, 100, and 101 cm showed differences less than 0.004. TrueBeam Developer Mode was used to collect continuous TMR data with the same accuracy as traditionally collected discrete data, but yielded higher sampled resolution and reduced acquisition time. This novel method does not require the modification of any equipment and does not use a 3D tank or reservoir. © 2017 American Association of Physicists in Medicine.
Wang, Feng-He; Zhang, Fan; Chen, Ya-Jun; Gao, Jay; Zhao, Bin
2015-12-30
Investigated in this paper were the content, specification distribution, and risk assessment code (RAC) determination of six targeted heavy metals and potentially toxic metals in fly ashes from a municipal solid waste incinerator in China. Contained in it is a comparison of the solidification/stabilization performance of two novel solidifying agents of sixthio guanidine acid (SGA) and tetrathio bicarbamic acid (TBA) with sodium dimethyldithiocarbamate (SDD) and Na2S, and analysis of their leachability in accordance with TCLP 1311 of the US EPA and the extraction procedures of China (HJ/T 299-2007 and HJ/T300-2007). The total concentration of Zn, Cu, Ni, Pb, Cr, Cd is 37383.47, 3080.77, 1583.92, 1356.43, 566.15, and 77.83 mg/kg, respectively. Cr (3.7%) and Pb (7.50%) pose low risk; and Ni (12.93%) and Zn (15.45%) have a medium risk; while Cu (69.84%) and Cd (82.5%) have a very high risk according to their RAC score. Compared with SDD and Na2S, SGA and TBA show an excellent overall solidifying performance due to their multiply hydrosulfide groups that bind with heavy metals very efficiently. The obtained results indicate that the leaching content of Cd, Ni, Pb and Zn is higher than the thresholds prescribed in GB5085.3-2007, and the excessive acetic acid makes its binding capacity stronger in HJ/T 300-2007 than in TCLP 1311. Copyright © 2015 Elsevier B.V. All rights reserved.
Neely, David; Zarubina, Anna V; Clark, Mark E; Huisingh, Carrie E; Jackson, Gregory R; Zhang, Yuhua; McGwin, Gerald; Curcio, Christine A; Owsley, Cynthia
2017-07-01
To examine the association between subretinal drusenoid deposits (SDDs) identified by multimodal retinal imaging and visual function in older eyes with normal macular health or in the earliest phases of age-related macular degeneration (AMD). Age-related macular degeneration status for each eye was defined according to the Age-Related Eye Disease Study (AREDS) 9-step classification system (normal = Step 1, early AMD = Steps 2-4) based on color fundus photographs. Visual functions measured were best-corrected photopic visual acuity, contrast and light sensitivity, mesopic visual acuity, low-luminance deficit, and rod-mediated dark adaptation. Subretinal drusenoid deposits were identified through multimodal imaging (color fundus photographs, infrared reflectance and fundus autofluorescence images, and spectral domain optical coherence tomography). The sample included 1,202 eyes (958 eyes with normal health and 244 eyes with early AMD). In normal eyes, SDDs were not associated with any visual function evaluated. In eyes with early AMD, dark adaptation was markedly delayed in eyes with SDDs versus no SDD (a 4-minute delay on average), P = 0.0213. However, this association diminished after age adjustment, P = 0.2645. Other visual functions in early AMD eyes were not associated with SDDs. In a study specifically focused on eyes in normal macular health and in the earliest phases of AMD, early AMD eyes with SDDs have slower dark adaptation, largely attributable to the older ages of eyes with SDD; they did not exhibit deficits in other visual functions. Subretinal drusenoid deposits in older eyes in normal macular health are not associated with any visual functions evaluated.
Rahnama, Leila; Rezasoltani, Asghar; Khalkhali-Zavieh, Minoo; Rahnama, Behnam; Noori-Kochi, Farhang
2015-01-01
OBJECTIVES: This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals. METHOD: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively. RESULTS: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects. CONCLUSIONS: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain. PMID:26443975
Köhn, J; Licher, J; Mielke, M; Loutfi-Krauss, B; Blümer, N; Heine, B; Rödel, C; Scherf, C; Ramm, U
2017-02-01
The use of Electronic Portal Imaging Devices (EPIDs) to acquire dosimetric information, especially for 3D-back-projection, has been increasingly extended. For a precise back-projection, the accurate knowledge of the movement characteristics of the EPID during gantry rotation is an essential requirement. Measurements were conducted with different alignments of steel balls, which were mounted on the treatment table to avoid secondary effects such as the mechanical sag of gantry or jaws. The image movement of the EPID was determined by comparing the predicted projections of the phantoms with the EPID acquired image. Effects on dosimetric verifications were evaluated by γ-evaluation. The measurement results showed that the shift of the EPID image is larger in Y direction than in X direction. A maximum rotation of 0.3° and nodding of 2.4° of the detector was calculated. Changes in SDD were found up to 10mm. The angles of nodding are overall higher at discrete gantry angles in comparison to images detected for continuous rotation. Using these results we were able to correct the EPID images used for verification measurements. γ-evaluation revealed a significantly improved agreement between planned and measured EPID signal values. The measurement methods and algorithms introduced in this study are simple and comprehensive. Using these methods and algorithms we were able to quantify the major effects on geometrical and dosimetric characteristics. This allows the correction of EPID signal measurements for these effects related to the gantry angle, leading to an improved γ-evaluation for treatment plans. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Front-end ASICs for high-energy astrophysics in space
NASA Astrophysics Data System (ADS)
Gevin, O.; Limousin, O.; Meuris, A.
2016-07-01
In most of embedded imaging systems for space applications, high granularity and increasing size of focal planes justify an almost systematic use of integrated circuits. . To fulfill challenging requirements for excellent spatial and energy resolution, integrated circuits must fit the sensors perfectly and interface the system such a way to optimize simultaneously noise, geometry and architecture. Moreover, very low power consumption and radiation tolerance are mandatory to envision a use onboard a payload in space. Consequently, being part of an optimized detection system for space, the integrated circuit is specifically designed for each application and becomes an Application Specific Integrated Circuits (ASIC). The paper focuses on mixed analog and digital signal ASICs for spectro-imaging systems in the keVMeV energy band. The first part of the paper summarizes the main advantages conferred by the use of front-end ASICs for highenergy astrophysics instruments in space mission. Space qualification of ASICs requires the chip to be radiation hard. The paper will shortly describe some of the typical hardening techniques and give some guidelines that an ASIC designer should follow to choose the most efficient technology for his project. The first task of the front-end electronics is to convert the charge coming from the detector into a voltage. For most of the Silicon detectors (CCD, DEPFET, SDD) this is conversion happens in the detector itself. For other sensor materials, charge preamplifiers operate the conversion. The paper shortly describes the different key parameters of charge preamplifiers and the binding parameters for the design. Filtering is generally mandatory in order to increase the signal to noise ratio or to reduce the duration of the signal. After a brief review on the main noise sources, the paper reviews noise-filtering techniques that are commonly used in Integrated circuits designs. The way sensors and ASICs are interconnected together plays a major role in the noise performances of the detection systems. The geometry of a sensor is therefore critical and drives the ASIC design. The second part of the paper takes the geometry of the detector as a story line to explore different kinds of ASIC structures and architectures. From the simple single-channel ASIC for CCDs to the most advanced 3D ASIC prototypes used to build dead-zone free imaging systems, the paper reports on different families of circuits for spectro-imaging systems. It emphasizes a variety of designer choices, all around the word, in different space missions.
Schefte, David B; Hetland, Merete L
2010-01-01
The Danish DANBIO registry has developed open-source software for touch screens in the waiting room. The objective was to assess the validity of outcomes from self-explanatory patient questionnaires on touch screen in comparison with the traditional paper form in routine clinical care. Fifty-two AS patients and 59 RA patients completed Visual Analogue Scales (VASs) for pain, fatigue and global health, and Bath measures on Ankylosing Spondylitis Disease Activity Index (BASDAI) and Function Index (BASFI) (AS patients) or HAQs (RA patients) on touch screen and paper form in random order with a 1-h interval. Intra-class correlation coefficients (ICCs), 95% CIs and smallest detectable differences (SDDs) were calculated. ICC ranged from 0.922 to 0.988 (P < 0.001). The mean differences (95% CI) were: BASDAI [-0.5 (-14.5, 13.5) mm]; BASFI [-1.1 (-10.6, 8.4) mm]; Item 5 [-1.7 (-23.6, 20.2) mm] and Item 6 [-0.7 (-14.7, 13.3) mm] from BASDAI; HAQ score [0.023 (-0.183, 0.229)]. For VAS -0.4 to -2.8 mm (no significance for all except VAS global and VAS fatigue in RA). SDD for BASDAI was 14.0 mm; BASFI 9.5 mm; Item 5 21.8 mm; Item 6 14.0 mm; HAQ 0.206; VAS 11.1-18.8 mm. Self-explanatory touch screens based on the DANBIO open-source system generates valid results in AS and RA patients on completion of BASDAI, BASFI, HAQ and VAS scores for pain, fatigue and global health when compared with the traditional paper form. Implementation of touch screens in clinical practice is feasible and patients need no instruction.
Thompson, Chad M.; Proctor, Deborah M.; Haws, Laurie C.; Hébert, Charles D.; Grimes, Sheila D.; Shertzer, Howard G.; Kopec, Anna K.; Hixon, J.Gregory; Zacharewski, Timothy R.; Harris, Mark A.
2011-01-01
Chronic ingestion of high concentrations of hexavalent chromium [Cr(VI)] in drinking water induces intestinal tumors in mice. To investigate the mode of action (MOA) underlying these tumors, a 90-day drinking water study was conducted using similar exposure conditions as in a previous cancer bioassay, as well as lower (heretofore unexamined) drinking water concentrations. Tissue samples were collected in mice exposed for 7 or 90 days and subjected to histopathological, biochemical, toxicogenomic, and toxicokinetic analyses. Described herein are the results of toxicokinetic, biochemical, and pathological findings. Following 90 days of exposure to 0.3–520 mg/l of sodium dichromate dihydrate (SDD), total chromium concentrations in the duodenum were significantly elevated at ≥ 14 mg/l. At these concentrations, significant decreases in the reduced-to-oxidized glutathione ratio (GSH/GSSG) were observed. Beginning at 60 mg/l, intestinal lesions were observed including villous cytoplasmic vacuolization. Atrophy, apoptosis, and crypt hyperplasia were evident at ≥ 170 mg/l. Protein carbonyls were elevated at concentrations ≥ 4 mg/l SDD, whereas oxidative DNA damage, as assessed by 8-hydroxydeoxyguanosine, was not increased in any treatment group. Significant decreases in the GSH/GSSG ratio and similar histopathological lesions as observed in the duodenum were also observed in the jejunum following 90 days of exposure. Cytokine levels (e.g., interleukin-1β) were generally depressed or unaltered at the termination of the study. Overall, the data suggest that Cr(VI) in drinking water can induce oxidative stress, villous cytotoxicity, and crypt hyperplasia in the mouse intestine and may underlie the MOA of intestinal carcinogenesis in mice. PMID:21712504
Replacing and Additive Horizontal Gene Transfer in Streptococcus
Choi, Sang Chul; Rasmussen, Matthew D.; Hubisz, Melissa J.; Gronau, Ilan; Stanhope, Michael J.; Siepel, Adam
2012-01-01
The prominent role of Horizontal Gene Transfer (HGT) in the evolution of bacteria is now well documented, but few studies have differentiated between evolutionary events that predominantly cause genes in one lineage to be replaced by homologs from another lineage (“replacing HGT”) and events that result in the addition of substantial new genomic material (“additive HGT”). Here in, we make use of the distinct phylogenetic signatures of replacing and additive HGTs in a genome-wide study of the important human pathogen Streptococcus pyogenes (SPY) and its close relatives S. dysgalactiae subspecies equisimilis (SDE) and S. dysgalactiae subspecies dysgalactiae (SDD). Using recently developed statistical models and computational methods, we find evidence for abundant gene flow of both kinds within each of the SPY and SDE clades and of reduced levels of exchange between SPY and SDD. In addition, our analysis strongly supports a pronounced asymmetry in SPY–SDE gene flow, favoring the SPY-to-SDE direction. This finding is of particular interest in light of the recent increase in virulence of pathogenic SDE. We find much stronger evidence for SPY–SDE gene flow among replacing than among additive transfers, suggesting a primary influence from homologous recombination between co-occurring SPY and SDE cells in human hosts. Putative virulence genes are correlated with transfer events, but this correlation is found to be driven by additive, not replacing, HGTs. The genes affected by additive HGTs are enriched for functions having to do with transposition, recombination, and DNA integration, consistent with previous findings, whereas replacing HGTs seen to influence a more diverse set of genes. Additive transfers are also found to be associated with evidence of positive selection. These findings shed new light on the manner in which HGT has shaped pathogenic bacterial genomes. PMID:22617954
Elius Hossain, Md; Mahmudul Hasan, Md; Halim, M E; Ehsan, M Q; Halim, Mohammad A
2015-03-05
Some transition metal complexes of phenylalanine of general formula [M(C9H10NO2)2]; where M=Mn(II), Co(II), Ni(II), Cu(II) and Zn(II) are prepared in aqueous medium and characterized by spectroscopic, thermo-gravimetric (TG) and magnetic susceptibility analysis. Density functional theory (DFT) has been employed calculating the equilibrium geometries and vibrational frequencies of those complexes at B3LYP level of theory using 6-31G(d) and SDD basis sets. In addition, frontier molecular orbital and time-dependent density functional theory (TD-DFT) calculations are performed with CAM-B3LYP/6-31+G(d,p) and B3LYP/SDD level of theories. Thermo-gravimetric analysis confirms the composition of the complexes by comparing the experimental and calculated data for C, H, N and metals. Experimental and computed IR results predict a significant change in vibrational frequencies of metal-phenylalanine complexes compared to free ligand. DFT calculation confirms that Mn, Co, Ni and Cu complexes form square planar structure whereas Zn adopts distorted tetrahedral geometry. The metal-oxygen bonds in the optimized geometry of all complexes are shorter compared to the metal-nitrogen bonds which is consistent with a previous study. Cation-binding energy, enthalpy and Gibbs free energy indicates that these complexes are thermodynamically stable. UV-vis and TD-DFT studies reveal that these complexes demonstrate representative metal-to-ligand charge transfer (MLCT) and d-d transitions bands. TG analysis and IR spectra of the metal complexes strongly support the absence of water in crystallization. Magnetic susceptibility data of the complexes exhibits that all except Zn(II) complex are high spin paramagnetic. Copyright © 2014 Elsevier B.V. All rights reserved.
Host modulation therapeutics in periodontics: role as an adjunctive periodontal therapy.
Shinwari, Muhammad Saad; Tanwir, Farzeen; Hyder, Pakiza Raza; Bin Saeed, Muhammad Humza
2014-09-01
Host Modulation Therapy (HMT) is a treatment concept that reduces tissue destruction and stabilizes or even regenerates inflammatory tissue by modifying host response factors. It has been used for treating osteoporosis and arthritis for several decades. However, its use in dentistry has only been recently reported. The objective of this article is to present a review of the various literatures available on HMT and also its role as adjunct therapy in periodontics. For identifying studies for this review, a PUBMED search was carried out in 2013 for all articles published till December 2012. The search was restricted to English language publications only. Longitudinal prospective and retrospective studies were included in the search. The key words used were: Host Modulation Therapy; Sub antimicrobial dose doxycycline and Non-Surgical Periodontal Therapy. The main outcomes sought were host modulation therapeutics in periodontics. Exclusion criteria included cross sectional studies, short case series as well as studies with short follow-up periods. There is a paucity of literature on HMT in periodontics although the only drug approved by United States Food and Drug Administration (FDA) is a subantimicrobial dose of doxycycline (SDD) with highly predictable results as a host modulating agent in periodontal diseases and also an effective adjunctive therapy in various diseases of periodontium. However, more randomized controlled trials are needed to obtain clinical guidelines on the usage of other host modulating agents as adjunct as well as definite therapy for periodontal diseases. SDD is an effective adjunct therapy when used in dosage of 20mg twice daily for minimum 3 months duration in various periodontal diseases with predictable clinical outcomes. It is also recommended that future clinical research on anti cytokine drugs, chemically modified tetracycline and other HMT agents should be conducted so that new drugs are available with highly predictable results.
Odor Control Test Report of the Urine Containment Bag (UCB) for Orion Utilization
NASA Technical Reports Server (NTRS)
Casper, Stephanie; Williams, Nichole M. M.
2010-01-01
The purpose of this report is to summarize the conclusions for the odor control test of the Urine Containment Bag (UCB), P/N SDD46107234-306 in an environment simulating a space craft capsule. JSC 65891, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization, documents the test plan. The details of the test set-up and data reduction are detailed in the WSTF test report for this test WSTF #10-44500, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization,. This document outlines the project conclusions and forward plans with regard to trash containment for Constellation.
Spiral biasing adaptor for use in Si drift detectors and Si drift detector arrays
Li, Zheng; Chen, Wei
2016-07-05
A drift detector array, preferably a silicon drift detector (SDD) array, that uses a low current biasing adaptor is disclosed. The biasing adaptor is customizable for any desired geometry of the drift detector single cell with minimum drift time of carriers. The biasing adaptor has spiral shaped ion-implants that generate the desired voltage profile. The biasing adaptor can be processed on the same wafer as the drift detector array and only one biasing adaptor chip/side is needed for one drift detector array to generate the voltage profiles on the front side and back side of the detector array.
1975-02-18
CA S " T .’ T !.I),_ SECURITY CLAS ’IFI’.0" ’. O3 THIS IA(.-! (W’,.en r).-e ,, ft, e-efd ""Rr.D INSTRUCTIONSREPORT DOCUMENTATION PAGE BEFORE COMPLETING...n•.• .-’ ~e.•b t .," •..-oa• -PORT :NUMBER•• V’efiat"p ea~ 1, RvINAF/ None .7- UTHOR(a.) ..... 8. CONTRACT OR GRANT NUMBER(&) Thomas C. rayfg...losses, population security, war costs and inflation and construction and port operations in South Vietnam.. SDD, FR17 1473 VDIT.ON OF, t OV 66 15 o.,o
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, X
Purpose: To explore the real-time dose verification method in volumetric modulated arc radiotherapy (VMAT) with a 2D array ion chamber array. Methods: The 2D ion chamber array was fixed on the panel of electronic portal imaging device (EPID). Source-detector distance (SDD)was 140cm. 8mm RW3 solid water was added to the detector panel to achieve maximum readings.The patient plans for esophageal, prostate and liver cancers were selected to deliver on the cylindrical Cheese phantom 5 times in order to validate the reproducibility of doses. Real-time patient transit dose measurements were performed at each fraction. Dose distributions wereevaluated using gamma index criteriamore » of 3mm DTA and 3% dose difference referred to the firsttime Result. Results: The gamma index pass rate in the Cheese phantom were about 98%; The gamma index pass rate for esophageal, liver and prostate cancer patient were about 92%,94%, and 92%, respectively; Gamma pass rate for all single fraction were more than 90%. Conclusion: The 2D array is capable of monitoring the real time transit doses during VMAT delivery. It is helpful to improve the treatment accuracy.« less
Prevention of hospital-acquired pneumonia: European perspective.
Bonten, Marc J M
2003-12-01
Several preventive measures for VAP have been empirically tested. There is clear evidence that antibiotic-containing preventive strategies, such as SDD and oropharyngeal decontamination, are very effective in different patient populations. Selection of antibiotic resistance remains the major disadvantage of these strategies, however, limiting its applicability in settings with high levels of antibiotic resistance. This probably precludes the use of these strategies in many American settings, but may allow their use in European countries with much lower endemic levels of resistance. There is little evidence that systemic prophylaxis is effective for the prevention of VAP, and initial studies were associated with resistance problems. Of the non antibiotic-containing preventive strategies, subglottic aspiration was effective in several studies, whereas other strategies, such as immunonutrition with glutamine or the semirecumbent patient position, were effective in single studies. All these studies were executed in European ICUs. For these interventions, more data are needed on the generalizability, feasibility, and cost effectiveness. Few data support the use of sucralfate for stress ulcer prophylaxis and modulation of enteral nutrition practices as preventive measures for VAP.
Detection and Analysis of X Ray Emission from the Princeton-Field-Reversed Configuration (PFRC-2)
NASA Astrophysics Data System (ADS)
Bosh, Alexandra; Swanson, Charles; Jandovitz, Peter; Cohen, Samuel
2016-10-01
The PFRC is an odd-parity rotating-magnetic-field-driven field-reversed-configuration magnetic confinement experiment. Studying X rays produced via electron Bremsstrahlung with neutral particles is crucial to the further understanding of the energy and particle confinement of the PFRC. The data on the x rays are collected using a detector system comprised of two, spatially scannable Amptek XR-100 CR detectors and a Amptek XR-100 SDD detector that view the plasma column at two axial locations, one in the divertor and one near the axial midplane. These provide X-ray energy and arrival-time information. (Data analysis requires measurement of each detector's efficiency, a parameter that is modified by window transmission. Detector calibrations were performed with a custom-made X-ray tube that impinged 1-microamp 1-5 kV electron beams onto a carbon target.) From the analyzed data, the average electron energy, effective temperature, and electron density can be extracted. Spatial scans then allow the FRC's internal energy to be measured. We present recent measurements of the Bremsstrahlung spectrum from 0.8 to 6 keV and the inferred electron temperature in the PFRC device as functions of heating power, magnetic field and fill gas pressure. This work was supported, in part, by DOE Contract Number DE-AC02-09CH11466.
Boltalin, A I; Korenev, Yu M; Sipachev, V A
2007-07-19
Molecular constants of MPbF3 (M=Li, Na, K, Rb, and Cs) were calculated theoretically at the MP2(full) and B3LYP levels with the SDD (Pb, K, Rb, and Cs) and cc-aug-pVQZ (F, Li, and Na) basis sets to determine the thermochemical characteristics of the substances. Satisfactory agreement with experiment was obtained, including the unexpected nonmonotonic dependence of substance dissociation energies on the alkali metal atomic number. The bond lengths of the theoretical CsPbF3 model were substantially elongated compared with experimental estimates, likely because of errors in both theoretical calculations and electron diffraction data processing.
NASA Technical Reports Server (NTRS)
Klingelhoefer, G.; Morris, R. V.; Blumers, M.; Bernhardt, B.; Graff, T.
2011-01-01
For the advanced Moessbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform X-ray fluorescence analysis simultaneously to Moessbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The ISRU 2010 field campaign demonstrated that in-situ Moessbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.
NASA Astrophysics Data System (ADS)
Kaya, Yunus; Kalkan, Yalçin; Veenhof, Rob
2018-02-01
In this work, a reaction mechanism of formation of noble gas (Ng) cluster ions has been theoretically investigated in detail. The kinetic studies of formation of Xe+Xe cluster in Xe, Ar+Ar cluster ions in Ar, and Ne+Ne cluster ions in Ne have been made as theoretically. The optimized structures in the ground state were calculated using the density functional theory (DFT) by the B3LYP method combined with the Stuttgart/Dresden effective core potential basis set (SDD). In addition, we calculated the rate constants of all cluster formations. The results are 1.15 × 10-31, 3.58 × 10-31, 0.23 × 10-31cm6/s, respectively for Neon, Argon, Xenon cluster ions.
NASA Astrophysics Data System (ADS)
Roy, Rajarshi; Thapa, Ranjit; Kumar, Gundam Sandeep; Mazumder, Nilesh; Sen, Dipayan; Sinthika, S.; Das, Nirmalya S.; Chattopadhyay, Kalyan K.
2016-04-01
In this work, we have demonstrated the signatures of localized surface distortions and disorders in functionalized graphene quantum dots (fGQD) and consequences in magneto-transport under weak field regime (~1 Tesla) at room temperature. Observed positive colossal magnetoresistance (MR) and its suppression is primarily explained by weak anti-localization phenomenon where competitive valley (inter and intra) dependent scattering takes place at room temperature under low magnetic field; analogous to low mobility disordered graphene samples. Furthermore, using ab-initio analysis we show that sub-lattice sensitive spin-polarized ground state exists in the GQD as a result of pz orbital asymmetry in GQD carbon atoms with amino functional groups. This spin polarized ground state is believed to help the weak anti-localization dependent magneto transport by generating more disorder and strain in a GQD lattice under applied magnetic field and lays the premise for future graphene quantum dot based spintronic applications.In this work, we have demonstrated the signatures of localized surface distortions and disorders in functionalized graphene quantum dots (fGQD) and consequences in magneto-transport under weak field regime (~1 Tesla) at room temperature. Observed positive colossal magnetoresistance (MR) and its suppression is primarily explained by weak anti-localization phenomenon where competitive valley (inter and intra) dependent scattering takes place at room temperature under low magnetic field; analogous to low mobility disordered graphene samples. Furthermore, using ab-initio analysis we show that sub-lattice sensitive spin-polarized ground state exists in the GQD as a result of pz orbital asymmetry in GQD carbon atoms with amino functional groups. This spin polarized ground state is believed to help the weak anti-localization dependent magneto transport by generating more disorder and strain in a GQD lattice under applied magnetic field and lays the premise for future graphene quantum dot based spintronic applications. Electronic supplementary information (ESI) available: UV-Vis spectrum of synthesized fGQDs, reconstructed false color surface topographic images from a high-resolution fGQD TEM lattice; Raman spectra with corresponding Breit-Wigner-Fano (BWF) line fitting of `G band' before and after the application of sTMF, spin density distribution (SDD) with different shapes of a functionalized graphene quantum dot, SDD of the main simulated fGQD model obtained using different exchange correlation functional (PW91, RBPE and LDA). Models of (a) two NH2 molecules adsorbed on a graphene sheet (periodic structure), (b) representing corresponding SPDOS are also provided. Charge density distribution (CDD) with two-dimensional side view contour plots of adsorbed -NH2 and O&z.dbd;C-NH2 on GQD lattice and SPDOS of a main fGQD model with 0.2% strain. See DOI: 10.1039/c5nr09292b
Contreras-Ruiz, José; Fuentes-Suárez, Adán; Arroyo-Escalante, Sara; Moncada-Barron, David; Sosa-de-Martínez, María Cristina; Maravilla-Franco, Ernesto; Domínguez-Cherit, Judith Guadalupe
2016-10-01
Maggot debridement therapy (MDT) is the use of medical grade maggots of the fly Lucilia sericata for wound debridement. Recent observations show that MDT decreases bacterial burden as well. Venous ulcers are the most commonly seen in wound clinics and require, besides adequate treatment of venous hypertension, proper wound bed preparation with debri dement of necrotic tissue and control of potential infections. To evaluate the efficacy of MDT in venous ulcers a randomized controlled trial was designed to compare MDT to surgical debridement and topical application of silver sulfadiazine (SSD) in 19 patients for 4 weeks. The study variables were area reduction, wound bed characteristics, pain, odor, anxiety and bacterial burden using quantitative tissue biopsies. MDT was effective as surgical debridement associated with topical SDD in the debridement of the wound and in reducing its size. A significant difference was observed in the reduction of bacterial burden in favor of the MDT group. Odor and anxiety increased in the MDT group without any difference in the pain intensity between groups. In conclusion, this study suggests that MDT is as effective as surgical debridement for the debridement of necrotic tissue and promote wound healing in venous ulcers and better at reducing bacterial burden.
Frencken, Jos F; Wittekamp, Bastiaan H J; Plantinga, Nienke L; Spitoni, Cristian; van de Groep, Kirsten; Cremer, Olaf L; Bonten, Marc J M
2018-02-01
Enteral and respiratory tract colonization with gram-negative bacteria may lead to subsequent infections in critically ill patients. We aimed to clarify the interdependence between gut and respiratory tract colonization and their associations with intensive care unit (ICU)-acquired infections in patients receiving selective digestive tract decontamination (SDD). Colonization status of the rectum and respiratory tract was determined using twice-weekly microbiological surveillance in mechanically ventilated subjects receiving SDD between May 2011 and June 2015 in a tertiary medical-surgical ICU in the Netherlands. Acquisition of infections was monitored daily by dedicated observers. Marginal structural models were used to determine the associations between gram-negative rectal colonization and respiratory tract colonization, ICU-acquired gram-negative infection, and ICU-acquired gram-negative bacteremia. Among 2066 ICU admissions, 1157 (56.0%) ever had documented gram-negative carriage in the rectum during ICU stay. Cumulative incidences of ICU-acquired gram-negative infection and bacteremia were 6.0% (n = 124) and 2.1% (n = 44), respectively. Rectal colonization was an independent risk factor for both respiratory tract colonization (cause-specific hazard ratio [CSHR], 2.93 [95% confidence interval {CI}, 2.02-4.23]) and new gram-negative infection in the ICU (CSHR, 3.04 [95% CI, 1.99-4.65]). Both rectal and respiratory tract colonization were associated with bacteremia (CSHR, 7.37 [95% CI, 3.25-16.68] and 2.56 [95% CI, 1.09-6.03], respectively). Similar associations were observed when Enterobacteriaceae and glucose nonfermenting gram-negative bacteria were analyzed separately. Gram-negative rectal colonization tends to be stronger associated with subsequent ICU-acquired gram-negative infections than gram-negative respiratory tract colonization. Gram-negative rectal colonization seems hardly associated with subsequent ICU-acquired gram-negative respiratory tract colonization. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Luis de Florez and the Special Devices Division
NASA Astrophysics Data System (ADS)
Dawson, Paul Louis
This Dissertation presents the life of Luis de Florez and the World War II history of the Special Devices Division (SDD) of the U.S. Navy's Bureau of Aeronautics. Luis de Florez was a well known consulting engineer, aviation fuel expert, private pilot and reserve Naval officer. While on active duty in 1940, he received the assignment to improve the Navy's flight training methods. To accomplish this objective, he promoted the concept of synthetic training, the use of simulators and other non-operational equipment, to provide training for Navy flight personnel such as pilots, gunners, navigators, flight engineers, radio operators and others as well as for ground based people like mechanics. He founded the Special Devices Division to design the tools and equipment needed for this type of training. The success of synthetic training and the devices developed by the SDD received recognition by the awarding of the Collier Trophy to de Florez in December 1944. This trophy is awarded annually for the most significant aeronautical achievement of the previous year (1943). De Florez received the award for the strategic accomplishment of training thousands of American airmen in 1943. The work of the Division also had other important technical, social, financial and operational impacts on the prosecution of WW II by the Allies. The work of the Division also had impacts on American society as a whole that persist to the present day. These impacts are discussed in detail. The Dissertation presents details of the devices and their use in aviation training as well as a history of the Division during the war. After the war, de Florez led an advisory board for the CIA. These activities and some of both the positive and negative results of the work of this board are discussed. This discussion includes de Florez' involvement in the CIA's drug experiments and the unfortunate Frank Olsen affair.
NASA Astrophysics Data System (ADS)
Ahangarianabhari, Mahdi; Macera, Daniele; Bertuccio, Giuseppe; Malcovati, Piero; Grassi, Marco
2015-01-01
We present the design and the first experimental characterization of VEGA, an Application Specific Integrated Circuit (ASIC) designed to read out large area monolithic linear Silicon Drift Detectors (SDD's). VEGA consists of an analog and a digital/mixed-signal section to accomplish all the functionalities and specifications required for high resolution X-ray spectroscopy in the energy range between 500 eV and 50 keV. The analog section includes a charge sensitive preamplifier, a shaper with 3-bit digitally selectable shaping times from 1.6 μs to 6.6 μs and a peak stretcher/sample-and-hold stage. The digital/mixed-signal section includes an amplitude discriminator with coarse and fine threshold level setting, a peak discriminator and a logic circuit to fulfill pile-up rejection, signal sampling, trigger generation, channel reset and the preamplifier and discriminators disabling functionalities. A Serial Peripherical Interface (SPI) is integrated in VEGA for loading and storing all configuration parameters in an internal register within few microseconds. The VEGA ASIC has been designed and manufactured in 0.35 μm CMOS mixed-signal technology in single and 32 channel versions with dimensions of 200 μm×500 μm per channel. A minimum intrinsic Equivalent Noise Charge (ENC) of 12 electrons r.m.s. at 3.6 μs peaking time and room temperature is measured and the linearity error is between -0.9% and +0.6% in the whole input energy range. The total power consumption is 481 μW and 420 μW per channel for the single and 32 channels version, respectively. A comparison with other ASICs for X-ray SDD's shows that VEGA has a suitable low noise and offers high functionality as ADC-ready signal processing but at a power consumption that is a factor of four lower than other similar existing ASICs.
Micro-XRF for In Situ Geological Exploration of Other Planets
NASA Technical Reports Server (NTRS)
Wade, Lawrence A.; Hodyss, Robert P.; Allwood, Abigail C.; Gao, Ning; Kozaczek, Kris
2013-01-01
In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis
Espinoza, A; Beeksma, B; Petasecca, M; Fuduli, I; Porumb, C; Cutajar, D; Corde, S; Jackson, M; Lerch, M L F; Rosenfeld, A B
2013-11-01
High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named "magic phantom." The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array "magic plate" (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the (192)Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a (192)Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ. The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of the epitaxial diodes used in the MP is in good agreement (within 8%) with radial dose function measurements found within the TG-43 protocol, with SDD of up to 70 mm showing a 40% over response. A method for four-dimensional localization of the HDR source was developed, allowing the source dwell position to be derived within 0.50 mm of the expected position. An estimation of the average transit speed for varying step sizes was determined and was found to increase from (12.8 ± 0.3) up to (38.6 ± 0.4) cm/s for a step size of 2.5 and 50 mm, respectively. Our characterization of the designed QA "magic phantom" with MP in realistic HDR photon fields demonstrates the promising performance for real-time source position tracking in four dimensions and measurements of transit times. Further development of this system will allow a full suite for QA in HDR brachytherapy and analysis, and for future in vivo tracking.
NASA Astrophysics Data System (ADS)
Marcelli, A.; Maggi, V.; Cibin, G.; Sala, M.; Marino, F.; Delmonte, B.
2006-12-01
We present the first x-ray absorption spectroscopy (XAS) data at the Fe K-edge collected on insoluble mineral dust from Talos Dome firn core (TDC, 159°04'E, 72°46'S, 2316 m a.s.l., mean accumulation rate 8 g cm-2 yr- 1), drilled in the framework of the International Trans Antarctic Scientific Expedition (ITASE), and from a Colle del Lys 2003 firn core (CDL03, 45°92'N, 7°86'E, 4248m a.s.l., mean accumulation rate 134 g cm-2 yr-1, Lys Glacier, Mt. Rosa, Italy). The low concentration of mineral particles, obtained by filtering each firn core melted samples on Nuclepore membranes in a 1000 class clean room, required a specific procedure to prepare the samples necessary to the successful collection of the XAS data. The firn samples were decontaminated in clean room under laminar flow bench by means of a ceramic knife and discarding the external part of the cores. Analyses of the insoluble particle content were performed by particle counter Beckman CounterãMultisizer III in order to defined concentration and size distribution of particles in each samples. A dedicated HV experimental chamber, devoted to the realization of XAS experiments on very low absorber concentration samples, was developed and realized in the framework of the CryoAlp collaboration at IMONT, the Italian National Institute for Mountains. The original experimental setup, thanks to the presence of an in-vacuum sample micromanipulator and special sample alignment and docking system installed for these experiments at the Stanford Synchrotron Radiation Laboratory at the beamline 6-2, allows both normal-incidence X-ray Fluorescence detection using a Ketek SDD detector having an energy resolution of about 150 eV and extremely low energy detection limit, and Total X-ray Reflection Fluorescence and Absorption Spectroscopy measurements. The high quality of the XANES experiments performed, using both normal incidence and Total Reflection XAS measurements, allowed recognizing iron-inclusion mineral fractions. Samples for Total Reflection XAS measurements were prepared just for this kind of measurements by depositing the insoluble mineral dust on clean Si wafer substrates. In addition, the XANES spectra show clear differences, corresponding to different samples mineral iron hosts, demonstrating that with this fully non-distructive technique, new information about the dust mineralogy at very low concentration can be performed. The analysis is then complementary to other well established techniques like XRD and PIXE.
SFERA: An Integrated Circuit for the Readout of X and gamma -Ray Detectors
NASA Astrophysics Data System (ADS)
Schembari, Filippo; Quaglia, Riccardo; Bellotti, Giovanni; Fiorini, Carlo
2016-06-01
In this work we present SFERA, a low-noise fully-programmable 16 channel readout ASIC designed for both Xand y-ray spectroscopy and imaging applications. The chip is designed to process signals coming from solid-state detectors and CMOS preamplifiers. The design has been guided by the use of Silicon Drift Detectors (SDDs) and CUBE charge sensitive amplifiers (CSAs), although we consider the ASIC sufficiently versatile to be used with other types of detectors. Five different gains are implemented, namely 2800 e-, 4400 e-, 10000 e-, 14000 e- and 20000 e-, considering the input connected to a 25 fF feedback capacitance CMOS preamplifier. Filter peaking times (tP) are also programmable among 0.5, 1, 2, 3, 4 and 6 μs. Each readout channel is the cascade of a 9th order semi-Gaussian shaping-amplifier (SA) and a peak detector (PKS), followed by a dedicated pile-up rejection (PUR) digital logic. Three data multiplexing strategies are implemented: the so-called polling X, intended for high-rate X-ray applications, the polling y, for scintillation light detection and the sparse, for signals derandomization. The spectroscopic characterization has shown an energy resolution of 122.1 eV FWHM on the Mn-Ku line of an 55Fe X-ray source using a 10 mm2 SDD cooled at -35 °C at 4 μs filter peaking time. The measured resolution is 130 eV at the peaking time of 500 ns. At 1 Mcps input count rate and 500 ns peaking time, we have measured 42% of processed events at the output of the ASIC after the PUR selection. Output data can be digitized on-chip by means of an embedded 12-bit successive-approximation ADC. The effective resolution of the data converter is 10.75-bit when operated at 4.5 MS/s. The chosen technology is the AMS 0.35 μm CMOS and the chip area occupancy is 5 × 5 mm2.
NASA Technical Reports Server (NTRS)
Westphal, Douglas L.; Russell, Philip (Technical Monitor)
1994-01-01
A set of 2,600 6-second, National Weather Service soundings from NASA's FIRE-II Cirrus field experiment are used to illustrate previously known errors and new potential errors in the VIZ and SDD brand relative humidity (RH) sensors and the MicroART processing software. The entire spectrum of RH is potentially affected by at least one of these errors. (These errors occur before being converted to dew point temperature.) Corrections to the errors are discussed. Examples are given of the effect that these errors and biases may have on numerical weather prediction and radiative transfer. The figure shows the OLR calculated for the corrected and uncorrected soundings using an 18-band radiative transfer code. The OLR differences are sufficiently large to warrant consideration when validating line-by-line radiation calculations that use radiosonde data to specify the atmospheric state, or when validating satellite retrievals. In addition, a comparison of observations of RE during FIRE-II derived from GOES satellite, raman lidar, MAPS analyses, NCAR CLASS sondes, and the NWS sondes reveals disagreement in the RH distribution and underlines our lack of an understanding of the climatology of water vapor.
NASA Technical Reports Server (NTRS)
Westphal, Douglas L.; Russell, Philip B. (Technical Monitor)
1994-01-01
A set of 2,600 6-second, National Weather Service soundings from NASA's FIRE-II Cirrus field experiment are used to illustrate previously known errors and new potential errors in the VIZ and SDD ) brand relative humidity (RH) sensors and the MicroART processing software. The entire spectrum of RH is potentially affected by at least one of these errors. (These errors occur before being converted to dew point temperature.) Corrections to the errors are discussed. Examples are given of the effect that these errors and biases may have on numerical weather prediction and radiative transfer. The figure shows the OLR calculated for the corrected and uncorrected soundings using an 18-band radiative transfer code. The OLR differences are sufficiently large to warrant consideration when validating line-by-line radiation calculations that use radiosonde data to specify the atmospheric state, or when validating satellite retrievals. in addition, a comparison of observations of RH during FIRE-II derived from GOES satellite, raman lidar, MAPS analyses, NCAR CLASS sondes, and the NWS sondes reveals disagreement in the RH distribution and underlines our lack of an understanding of the climatology of water vapor.
NASA Astrophysics Data System (ADS)
Pajouhafsar, Yasmin; Alis Manso Rodriguez Team; Sherry Yennello Team
2017-09-01
Particle Induced X-Ray Emission (PIXE) is a non-destructive analytical technique that is used for various tasks, such as elemental composition. The x-rays are emitted when electrons transition from higher to lower energy levels, causing vacancies in the atom's electron configuration. The overall goals of this research are to successfully set up a PIXE experiment and to obtain elemental concentrations for various samples, using the K150 proton beam in the Cyclotron Institute at Texas A&M University. The x-rays produced are unique to each element and analyzed with reference to their known energies. The setup consists of 3 different detectors, providing a wide range of energies: XR-100T CdTe γ/X-Ray, XR-100T/CR Si and XR-100SDD. Accelerating 3.6 MeV protons from the K150 and using PIXE, we determine concentrations from the NaCl samples provided by the Chemical Engineering Department. The concentrations for each element found in the NaCl thin films are obtained and analyzed through the software, GUPIXWIN. DOE Grant (DE-FG02-93ER40773) and Welch Foundation (A-1266).
Confirmatory analysis of field-presumptive GSR test sample using SEM/EDS
NASA Astrophysics Data System (ADS)
Toal, Sarah J.; Niemeyer, Wayne D.; Conte, Sean; Montgomery, Daniel D.; Erikson, Gregory S.
2014-09-01
RedXDefense has developed an automated red-light/green-light field presumptive lead test using a sampling pad which can be subsequently processed in a Scanning Electron Microscope for GSR confirmation. The XCAT's sampling card is used to acquire a sample from a suspect's hands on the scene and give investigators an immediate presumptive as to the presence of lead possibly from primer residue. Positive results can be obtained after firing as little as one shot. The same sampling card can then be sent to a crime lab and processed on the SEM for GSR following ASTM E-1588-10 Standard Guide for Gunshot Residue Analysis by Scanning Electron Microscopy/Energy Dispersive X-Ray Spectrometry, in the same manner as the existing tape lifts currently used in the field. Detection of GSR-characteristic particles (fused lead, barium, and antimony) as small as 0.8 microns (0.5 micron resolution) has been achieved using a JEOL JSM-6480LV SEM equipped with an Oxford Instruments INCA EDS system with a 50mm2 SDD detector, 350X magnification, in low-vacuum mode and in high vacuum mode after coating with carbon in a sputter coater. GSR particles remain stable on the sampling pad for a minimum of two months after chemical exposure (long term stability tests are in progress). The presumptive result provided by the XCAT yields immediate actionable intelligence to law enforcement to facilitate their investigation, without compromising the confirmatory test necessary to further support the investigation and legal case.
Determination of fluorine by total reflection X-ray fluorescence spectrometry
NASA Astrophysics Data System (ADS)
Tarsoly, G.; Óvári, M.; Záray, Gy.
2010-04-01
There is a growing interest in determination of low Z elements, i.e. carbon to phosphorus, in various samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as a suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). In this study, the analytical performance of the total reflection X-ray fluorescence spectrometry for determination of fluorine was investigated applying a spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a silicon drift detector (SDD) with ultra thin window was used. The detection limit for fluorine was found to be 5 mg L - 1 (equivalent to 10 ng absolute) in aqueous matrix. The linear range of the fluorine determination is between 15 and 500 mg L - 1 , within this range the precision is below 10%. The matrix effects of the other halogens (chlorine, bromine and iodine), and sulfate were also investigated. It has been established that the upper allowed concentration limit of the above interfering elements is 100, 200, 50 and 100 mg L - 1 for Cl, Br, I and sulfate, respectively. Moreover, the role of the pre-siliconization of the quartz carrier plate was investigated. It was found, that the presence of the silicone results in poorer analytical performance, which can be explained by the thicker sample residue and stronger self-absorption of the fluorescent radiation.
NASA Astrophysics Data System (ADS)
Luque-Ceballos, Jonathan C.; Posada-Borbón, Alvaro; Herrera-Urbina, Ronaldo; Aceves, R.; Juárez-Sánchez, J. Octavio; Posada-Amarillas, Alvaro
2018-03-01
Spectroscopic properties of gas-phase copper sulfide clusters (CuS)n (n = 2-6) are calculated using Density Functional Theory (DFT) and time-dependent (TD) DFT approaches. The energy landscape of the potential energy surface is explored through a basin-hopping DFT methodology. Ground-state and low-lying isomer structures are obtained. The global search was performed at the B3PW91/SDD level of theory. Normal modes are calculated to validate the existence of optimal cluster structures. Energetic properties are obtained for the ground-state and isomer clusters and their relative energies are evaluated for probing isomerization. This is a few tenths of an eV, except for (CuS)2 cluster, which presents energy differences of ∼1 eV. Notable differences in the infrared spectra exist between the ground-state and first isomer structures, even for the (CuS)5 cluster, which has in both configurations a core copper pyramid. TDDFT provides the simulated absorption spectrum, presenting a theoretical description of optical absorption bands in terms of electronic excitations in the UV and visible regions. Results exhibit a significant dependence of the calculated UV/vis spectra on clusters size and shape regarding the ground state structures. Optical absorption is strong in the UV region, and weak or forbidden in the visible region of the spectrum.
[Ventilator associated pneumonia].
Bellani, S; Nesci, M; Celotto, S; Lampati, L; Lucchini, A
2003-04-01
Ventilator associated pneumonia (VAP) is a nosocomial lower respiratory tract infection that ensues in critically ill patients undergoing mechanical ventilation. The reported incidence of VAP varies between 9% and 68% with a mortality ranging between 33% and 71%. Two key factors are implicated in the pathogenesis of VAP: bacterial colonization of the upper digestive-respiratory tract and aspiration of oral secretions into the trachea. Preventive measurements are advocated to reduce the incidence of VAP, such as selective decontamination of the digestive tract (SDD), supraglottic aspiration and positioning. Prompt recognition and treatment of established VAP has also been demostrated to affect outcome. Therefore, the knowledge of risk factors associated with the development of VAP and the implementation of strategies to prevent, diagnose and treat VAP are mainstems in the nursing of mechanically ventilated patients.
FPGA implementation of advanced FEC schemes for intelligent aggregation networks
NASA Astrophysics Data System (ADS)
Zou, Ding; Djordjevic, Ivan B.
2016-02-01
In state-of-the-art fiber-optics communication systems the fixed forward error correction (FEC) and constellation size are employed. While it is important to closely approach the Shannon limit by using turbo product codes (TPC) and low-density parity-check (LDPC) codes with soft-decision decoding (SDD) algorithm; rate-adaptive techniques, which enable increased information rates over short links and reliable transmission over long links, are likely to become more important with ever-increasing network traffic demands. In this invited paper, we describe a rate adaptive non-binary LDPC coding technique, and demonstrate its flexibility and good performance exhibiting no error floor at BER down to 10-15 in entire code rate range, by FPGA-based emulation, making it a viable solution in the next-generation high-speed intelligent aggregation networks.
NASA Astrophysics Data System (ADS)
Swanson, C.; Jandovitz, P.; Cohen, S. A.
2018-02-01
We measured Electron Energy Distribution Functions (EEDFs) from below 200 eV to over 8 keV and spanning five orders-of-magnitude in intensity, produced in a low-power, RF-heated, tandem mirror discharge in the PFRC-II apparatus. The EEDF was obtained from the x-ray energy distribution function (XEDF) using a novel Poisson-regularized spectrum inversion algorithm applied to pulse-height spectra that included both Bremsstrahlung and line emissions. The XEDF was measured using a specially calibrated Amptek Silicon Drift Detector (SDD) pulse-height system with 125 eV FWHM at 5.9 keV. The algorithm is found to out-perform current leading x-ray inversion algorithms when the error due to counting statistics is high.
Fungal Profile of Vulvovaginal Candidiasis in a Tertiary Care Hospital.
Kalaiarasan, Krishnapriya; Singh, Rakesh; Chaturvedula, Latha
2017-03-01
Vulvovaginal Candidiasis (VVC) is a common medical health problem of adult women. It is most commonly caused by Candida albicans . But there is a change in fungal profile. Sabouraud's Dextrose Agar (SDA) is the most common culture medium used where mixed fungal infection may be missed. It can be detected easily by using chromogenic culture medium. To know the fungal profile of vulvovaginal candidiasis using Candida CHROMagar and antifungal susceptibility pattern in patients attending tertiary care hospital. Culture confirmed cases of VVC presented at Department of Obstetrics and Gynaecology of Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India, from July 2015 to December 2015 were included in the cross-sectional study. Two high vaginal swabs were collected and inoculated on SDA and Candida CHROMagar (Hi-Media, Mumbai, India). After overnight incubation the colonies were counted and colour of the colonies were recorded from Candida CHROMagar. Candida spp. were identified by sugar fermentation and assimilation tests and other conventional tests. Antifungal susceptibility tests were performed by the disc diffusion method using fluconazole (25 μg) and voriconazole (1μg) as per the Clinical and Laboratory Standards Institute (CLSI - M44-A2) guidelines. A total of 50 culture confirmed (23.7%) cases were detected from 211 clinically suspected VVC cases. Candida glabrata (45.1%) was the most common isolate, followed by Candida tropicalis (23.5%) , Candida albicans (17.6%) , Candida krusei (9.8%) and Candida parapsilosis (3.9%) . One mixed infection of C. glabrata and C. albicans was identified on Candida CHROMagar. Mixed fungal infection was observed in 2% of positive culture and 0.5% of VVC cases. The antifungal susceptibility testing revealed that 15.7% and 9.8% isolates of Candida spp. were resistant and Susceptible Dose Dependent (S-DD) respectively to fluconazole. The increase resistant against fluconazole was because of increased isolation of C. glabrata strains. All strains of Candida spp. were susceptible to voriconazole. C. glabrata was the most common causative agent of VVC in a tertiary care hospital. Chromogenic culture medium facilitates detection of mixed fungal infection. In vitro susceptibility testing should be used to guide the treatment especially in cases of non- albicans Candidiasis.
Swanson, C.; Jandovitz, P.; Cohen, S. A.
2018-02-27
We measured Electron Energy Distribution Functions (EEDFs) from below 200 eV to over 8 keV and spanning five orders-of-magnitude in intensity, produced in a low-power, RF-heated, tandem mirror discharge in the PFRC-II apparatus. The EEDF was obtained from the x-ray energy distribution function (XEDF) using a novel Poisson-regularized spectrum inversion algorithm applied to pulse-height spectra that included both Bremsstrahlung and line emissions. The XEDF was measured using a specially calibrated Amptek Silicon Drift Detector (SDD) pulse-height system with 125 eV FWHM at 5.9 keV. Finally, the algorithm is found to out-perform current leading x-ray inversion algorithms when the error duemore » to counting statistics is high.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swanson, C.; Jandovitz, P.; Cohen, S. A.
We measured Electron Energy Distribution Functions (EEDFs) from below 200 eV to over 8 keV and spanning five orders-of-magnitude in intensity, produced in a low-power, RF-heated, tandem mirror discharge in the PFRC-II apparatus. The EEDF was obtained from the x-ray energy distribution function (XEDF) using a novel Poisson-regularized spectrum inversion algorithm applied to pulse-height spectra that included both Bremsstrahlung and line emissions. The XEDF was measured using a specially calibrated Amptek Silicon Drift Detector (SDD) pulse-height system with 125 eV FWHM at 5.9 keV. Finally, the algorithm is found to out-perform current leading x-ray inversion algorithms when the error duemore » to counting statistics is high.« less
NASA Astrophysics Data System (ADS)
Vadrucci, M.; Bazzano, G.; Borgognoni, F.; Chiari, M.; Mazzinghi, A.; Picardi, L.; Ronsivalle, C.; Ruberto, C.; Taccetti, F.
2017-09-01
In the framework of the COBRA project, elemental analyses of cultural heritage objects based on the particle induced X-ray emission (PIXE) are planned in a collaboration between the APAM laboratory of ENEA-Frascati and the LABEC laboratory of INFN in Florence. With this aim a 3-7 MeV pulsed proton beam, driven by the injector of the protontherapy accelerator under construction for the TOP-IMPLART project, will be used to demonstrate the feasibility of the technique with a small-footprint pulsed accelerator to Italian small and medium enterprises interested in the composition analysis of ancient artifacts. The experimental set-up for PIXE analysis on the TOP-IMPLART machine consists of a modified assembly of the vertical beam line usually dedicated to radiobiology experiments: the beam produced by the injector (RFQ + DTL, a PL7 ACCSYSHITACHI model) is bent to 90° by a magnet, is collimated by a 300 μm aperture inserted in the end nozzle and extracted into ambient pressure by an exit window consisting of a Upilex foil 7.5 μm thick. The beam is pulsed with a variable pulse duration of 20-100 μs and a repetition rate variable from 10 to 100 Hz. The X-ray detection system is based on a Ketek Silicon Drift Detector (SDD) with 7 mm2 active area and 450 μm thickness, with a thin Beryllium entrance window (8 μm). The results of the calibration of this new PIXE set-up using thick target standards and of the analysis of the preliminary measurements on pigments are presented.
Content of system design descriptions
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
A System Design Description (SDD) describes the requirements and features of a system. This standard provides guidance on the expected technical content of SDDs. The need for such a standard was recognized during efforts to develop SDDs for safety systems at DOE Hazard Category 2 nonreactor nuclear facilities. Existing guidance related to the corresponding documents in other industries is generally not suitable to meet the needs of DOE nuclear facilities. Across the DOE complex, different contractors have guidance documents, but they vary widely from site to site. While such guidance documents are valuable, no single guidance document has all themore » attributes that DOE considers important, including a reasonable degree of consistency or standardization. This standard is a consolidation of the best of the existing guidance. This standard has been developed with a technical content and level of detail intended to be most applicable to safety systems at DOE Hazard Category 2 nonreactor nuclear facilities. Notwithstanding that primary intent, this standard is recommended for other systems at such facilities, especially those that are important to achieving the programmatic mission of the facility. In addition, application of this standard should be considered for systems at other facilities, including non-nuclear facilities, on the basis that SDDs may be beneficial and cost-effective.« less
Honnavar, Prasanna; Chakrabarti, Arunaloke; Prasad, Ghandam S; Singh, Pankaj; Dogra, Sunil; Rudramurthy, Shivaprakash M
2017-02-01
β-Endorphin is known to stimulate phospholipase production by Malassezia pachydermatis during canine dermatoses. The role of β-endorphin in Malassezia infection in humans is not well studied. The present study compares the influence of β-endorphin on Malassezia globosa and Malassezia restricta isolated from patients with seborrhoeic dermatitis/dandruff (SD/D) and healthy controls. Malassezia isolates (five each of the two species from patients and healthy controls) were grown on modified Dixon's agar with or without 100 nmol/L β-endorphin. Phospholipase activity was quantified based on its ability to hydrolyze L-α-phosphatidylcholine dimyristoyl (phospholipid substrate). Free fatty acid was measured by a colorimetry method. In isolates from patients, the phospholipase activity significantly increased after exposure to β-endorphin (M. globosa, P = .04; M. restricta, P = .001), which did not occur in isolates from healthy controls. Moreover, after β-endorphin exposure the patient isolates had significantly higher (P = .0004) phospholipase activity compared to the healthy control isolates. The results suggest that isolates of M. globosa and M. restricta from patients may differ from those of healthy humans. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Kennedy, Craig H; Juárez, A Pablo; Becker, Angela; Greenslade, Kathryn; Harvey, Mark T; Sullivan, Clare; Tally, Brenna
2007-12-01
We studied whether children with severe developmental disabilities (SDDs) who have a comorbid behavioral disorder also have higher rates of special healthcare needs (SHCNs). We used a matched-comparison control group design to establish whether SHCNs were higher in children with SDDs with behavioral disorders versus children with SDDs without behavioral disorders. Thirty-six children were matched for age (mean 12 y 6 mo; range 5 y 2 mo-18 y 8 mo), sex (24 males, 12 females), ethnicity (22 non-white), mental retardation level (22 moderate, eight severe, six profound), and Diagnostic and Statistical Manual of Mental Disorders, 4th edition axis I diagnosis (18 autism spectrum disorder, 10 specified syndrome, eight mental retardation not otherwise specified). Measures included the Achenbach Child Behavior Checklist, behavioral observation, health status examination, and Childhood Health Questionnaire (CHQ). Children with SDDs with behavioral disorders had significantly higher levels of SHCN, as measured by the CHQ and health status examination. Children with SDDs with behavioral disorders had a twofold higher incidence of SHCNs than children with SDDs without behavioral disorders. No difference was observed in the number or types of prescription medication that children received. The findings suggest that SHCNs contribute to the occurrence and/or intensity of behavioral disorders in children with SDD and may require interdisciplinary care coordination.
TOMOX : An X-rays tomographer for planetary exploration
NASA Astrophysics Data System (ADS)
Marinangeli, Lucia; Pompilio, Loredana; Chiara Tangari, Anna; Baliva, Antonio; Alvaro, Matteo; Chiara Domeneghetti, Maria; Frau, Franco; Melis, Maria Teresa; Bonanno, Giovanni; Consolata Rapisarda, Maria; Petrinca, Paolo; Menozzi, Oliva; Lasalvia, Vasco; Pirrotta, Simone
2017-04-01
The TOMOX instrument has recently been founded under the ASI DC-EOS-2014-309 call. The TOMOX objective is to acquire both X-ray fluorescence and diffraction measurements from a sample in order to: a) achieve its chemical and mineralogical composition; b) reconstruct a 3D tomography of the sample exposed surface; c) give hints regarding the sample age. Nevertheless, this technique has applicability in several disciplines other than planetary geology, especially archaeology. The word 'tomography' is nowadays used for many 3D imaging methods, not just for those based on radiographic projections, but also for a wider range of techniques that yield 3D images. Fluorescence tomography is based on the signal produced on an energy-sensitive detector, generally placed in the horizontal plane at some angle with respect to the incident beam caused by photons coming from fluorescence emission. So far, a number of setups have been designed in order to acquire X-rays fluorescence tomograms of several different sample types. The proposed instrument is based on the MARS-XRD heritage, an ultra miniaturised XRD and XRF instrument developed for the ESA ExoMars mission. The general idea of TOMOX is to distribute both sources and detectors along a moving hemispherical support around the target sample. As a result, both sources move integrally with the detectors while the sample is observed from a fixed position, thus preserving the geometry of observation. In that way, the whole sample surface is imagined and XRD and XRF measurements are acquired continuously along all the scans. We plan to irradiate the target sample with X-rays emitted from 55Fe and 109Cd radioactive sources. 55Fe and 109Cd radioisotopes are commonly used as X-ray sources for analysis of metals in soils and rocks. The excitation energies of 55Fe and 109Cd are 5.9 keV, and 22.1 and 87.9 keV, respectively. Therefore, the elemental analysis ranges are Al to Mn with K lines excited with 55Fe; Ca to Rh, with K lines excited with 109Cd. 55Fe will be primarily dedicated to XRD measurements, as it has been already tested for the MARS-XRD development. 109Cd will be used to reinforce the efficiency of 55Fe source in the production of fluorescent X-rays generated in the sample as a consequence of irradiation and to extend the analytical range of elements. Two different detectors will be used in order to increase the total amount of events collected and allow the spatial distribution of events to be recorded as well. The detectors we plan to use are SDD (Silicon Drift Detector) and stand-alone CCD (Coupled Charge Detector). SDD has higher count rate and stability and has been successfully used for XRF applications. CCD is able to record the spatial position of each event of X-ray emission, together with its energy. Therefore, we plan to dedicate this detector to XRD measurements, where the spatial position of the event is directly correlated to the type of crystal through the Bragg's law. A prototype of the instrument will be likely completed by the end of this year.
NASA Astrophysics Data System (ADS)
El-Mansy, M. A. M.
2017-08-01
Structural and vibrational spectroscopic studies were performed on indigo carmine (IC) isomers using FT-IR spectral analysis along with DFT/B3LYP method utilizing Gaussian 09 software. GaussView 5 program has been employed to perform a detailed interpretation of vibrational spectra. Simulation of infrared spectra has led to an excellent overall agreement with the observed spectral patterns. Mulliken population analyses on atomic charges, MEP, HOMO-LUMO, NLO, first order hyperpolarizability and thermodynamic properties have been examined by (DFT/B3LYP) method with the SDD basis set level. Density of state spectra (DOS) were calculated using GaussSum 3 at the same level of theory. Molecular modeling approved that DOS Spectra are the most significant tools for differentiating between two IC isomers so far. Moreover, The IC isomers (cis-isomer) have shown an extended applicability for manufacturing both NLO and photovoltaic devices such as solar cells.
NASA Technical Reports Server (NTRS)
1981-01-01
The results of magnet system special investigations listed below are summarized: 4 Tesla Magnet Alternate Design Study; 6 Tesla Magnet Manufacturability Study. The conceptual design for a 4 Tesla superconducting magnet system for use with an alternate (supersonic) ETF power train is described, and estimated schedule and cost are identified. The magnet design is scaled from the ETF 6 T Tesla design. Results of a manufacturability study and a revised schedule and cost estimate for the ETF 6 T magnet are reported. Both investigations are extensions of the conceptual design of a 6 T magnet system performed earlier as a part of the overall MED-ETF conceptual design described in Conceptual Design Engineering Report (CDER) Vol. V, System Design Description (SDD) 503 dated September, 1981, DOE/NASA/0224-1; NASA CR-165/52.
Plutonium Finishing Plant (PFP) HVAC System Component Index
DOE Office of Scientific and Technical Information (OSTI.GOV)
DICK, J.D.
2000-02-28
The Plutonium Finishing Plant (PFP) WAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.'' This document lists safety class and safety significant components for the Heating Ventilation Air Conditioning and specifies the critical characteristics for Commercial Grade Items, as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that themore » equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item.« less
NASA Astrophysics Data System (ADS)
Ouasri, A.; El-Adel, L.; Zouihri, H.; Rhandour, A.; Jalbout, A. F.
2018-04-01
Diethylammonium hexachloroplumbate [(C2H5)2NH2]2PbCl6 was found to be monoclinic with P21/n (Z = 2) as space group at room temperature. The TGA analysis shows that this compound is slightly hygroscopic and presents moisture in itself. The Raman spectrum (50-4000 cm-1) of this compound recorded at room temperature was discussed on the basis of the factor group analysis using the structural data obtained recently [5]. The experimental frequencies are compared to those obtained by Density Functional Theory (DFT) by using the B3LYP functional and the 6-31G(d) (SDD) basis set. The thermodynamic properties and geometries of this compound have been determinated and characterized. The significant intermolecular interactions in the crystal structure are identified and analyzed using the Hirshfeld surface and fingerprint plots computational methods.
Zheng, Xufeng; Fu, Nan; Huang, Song; Jeantet, Romain; Chen, Xiao Dong
2016-12-01
Protective carriers that encapsulate probiotics in spray drying could improve the survival ratio of dried cells through different mechanisms. Unveiling the protective mechanism of each carrier will contribute to a rational design of high performance carrier formulation. This study utilized single droplet drying (SDD) technique to investigate the effects of calcium cation in varied carrier formulation. Inactivation histories of Lactobacillus rhamnosus GG (LGG) in different carriers were compared, and cellular injury history of probiotics during droplet drying was studied for the first time. Adding 1mM CaCl 2 to lactose carrier protected cell viability, mitigated cellular injuries, and enhanced regrowth capability as drying progressed, demonstrating the positive effect of Ca 2+ with possible mechanism of stabilizing sub-cellular structures. At later drying stages, cell survival in Lac/Ca carrier was increased by 0.5-1.5 log on selective media compared to lactose carrier. Supplementing calcium-binding agents lowered the protective effect, shortening the initiation of rapid cell inactivation down to 120s of drying. Adding CaCl 2 to trehalose carrier barely improved cell survival, indicating that the protective effect could be influenced by carrier formulation. Pure trehalose carrier exerted excellent protection on LGG, supporting cells to regrow in liquid rich medium even after 180s of drying. The protection of trehalose may stem from stabilization of sub-cellular structures, which possibly overlap the effect of Ca 2+ . The findings suggested that high performance carrier formulation might be developed by combining carrier materials with different protective mechanisms, for maximizing the survival of active dry probiotics in industrial spray drying operation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Measuring human remains in the field: Grid technique, total station, or MicroScribe?
Sládek, Vladimír; Galeta, Patrik; Sosna, Daniel
2012-09-10
Although three-dimensional (3D) coordinates for human intra-skeletal landmarks are among the most important data that anthropologists have to record in the field, little is known about the reliability of various measuring techniques. We compared the reliability of three techniques used for 3D measurement of human remain in the field: grid technique (GT), total station (TS), and MicroScribe (MS). We measured 365 field osteometric points on 12 skeletal sequences excavated at the Late Medieval/Early Modern churchyard in Všeruby, Czech Republic. We compared intra-observer, inter-observer, and inter-technique variation using mean difference (MD), mean absolute difference (MAD), standard deviation of difference (SDD), and limits of agreement (LA). All three measuring techniques can be used when accepted error ranges can be measured in centimeters. When a range of accepted error measurable in millimeters is needed, MS offers the best solution. TS can achieve the same reliability as does MS, but only when the laser beam is accurately pointed into the center of the prism. When the prism is not accurately oriented, TS produces unreliable data. TS is more sensitive to initialization than is MS. GT measures human skeleton with acceptable reliability for general purposes but insufficiently when highly accurate skeletal data are needed. We observed high inter-technique variation, indicating that just one technique should be used when spatial data from one individual are recorded. Subadults are measured with slightly lower error than are adults. The effect of maximum excavated skeletal length has little practical significance in field recording. When MS is not available, we offer practical suggestions that can help to increase reliability when measuring human skeleton in the field. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
The effect of reactions on the formation and readout of the gradient of Bicoid
NASA Astrophysics Data System (ADS)
Perez Ipiña, Emiliano; Ponce Dawson, Silvina
2017-02-01
During early development, the establishment of gradients of transcriptional factors determines the patterning of cell fates. The case of Bicoid (Bcd) in Drosophila melanogaster embryos is well documented and studied. There are still controversies as to whether SDD models in which Bcd is Synthesized at one end, then Diffuses and is Degraded can explain the gradient formation within the timescale observed experimentally. The Bcd gradient is observed in embryos that express a Bicoid-eGFP fusion protein (Bcd-GFP) which cannot differentiate if Bcd is freely diffusing or bound to immobile sites. In this work we analyze an SDID model that includes the Interaction of Bcd with binding sites. We simulate numerically the resulting full reaction-diffusion system in a cylindrical domain using previously determined biophysical parameters and a simplified version of the Bcd source. In this way we obtain solutions that depend on the spatial location approximately as observed experimentally and that reach such dependence at a time that is also compatible with the experimental observations. Analyzing the differences between the free and bound Bcd distributions we observe that the latter spans over a longer lengthscale. We conclude that deriving the lengthscale from the distribution of Bcd-GFP can lead to an overestimation of the gradient lengthscale and of the Hill coefficient that relates the concentrations of Bcd and of the protein, Hunchback, whose production is regulated by Bcd.
Tsai, Ching-Piao; Lin, Feng-Cheng; Lee, Charles Tzu-Chi
2014-10-01
The aim of this study was to investigate whether the use of fenoterol, a beta2-adrenergic agonist, was associated with multiple sclerosis (MS) risk by conducting a total population-based case-control study in Taiwan. A total of 578 patients with newly diagnosed MS who had a severely disabling disease (SDD) certificate between January 1, 2002 and December 1, 2008 comprised the case group. These cases were compared with 2890 gender-, age-, residence-, and insurance premium-matched controls. Fenoterol use was analyzed using a conditional logistic regression model that controlled for asthma, chronic obstructive pulmonary disease (COPD), salbutamol and steroid use. Compared with the group of people who did not use fenoterol, the adjusted odds ratios were 0.67 (95% confidence interval (CI) = 0.48-0.93, p = 0.016) for the group prescribed fenoterol below 2.25 cumulative defined daily dose (cDDD) and 0.49 (95% CI = 0.33-0.71, p < 0.001) for the group with a cumulative fenoterol use of more than 2.25 cDDD. The dose-response relationship was similar within the non-asthma patients. The associations were similar between males and females, but differences between age groups were observed. The results of this study suggest that fenoterol use may reduce the risk of MS. © The Author(s), 2014.
Risk and benefit of diffraction in Energy Dispersive X-ray fluorescence mapping
NASA Astrophysics Data System (ADS)
Nikonow, Wilhelm; Rammlmair, Dieter
2016-11-01
Energy dispersive X-ray fluorescence mapping (μ-EDXRF) is a fast and non-destructive method for chemical quantification and therefore used in many scientific fields. The combination of spatial and chemical information is highly valuable for understanding geological processes. Problems occur with crystalline samples due to diffraction, which appears according to Bragg's law, depending on the energy of the X-ray beam, the incident angle and the crystal parameters. In the spectra these peaks can overlap with element peaks suggesting higher element concentrations. The aim of this study is to investigate the effect of diffraction, the possibility of diffraction removal and potential geoscientific applications for X-ray mapping. In this work the μ-EDXRF M4 Tornado from Bruker was operated with a Rh-tube and polychromatic beam with two SDD detectors mounted each at ± 90° to the tube. Due to the polychromatic beam the Bragg condition fits for several mineral lattice planes. Since diffraction depends on the angle, it is shown that a novel correction approach can be applied by measuring from two different angles and calculating the minimum spectrum of both detectors gaining a better limit of quantification for this method. Furthermore, it is possible to use the diffraction information for separation of differently oriented crystallites within a monomineralic aggregate and obtain parameters like particle size distribution for the sample, as it is done by thin section image analysis in cross-polarized light. Only with μ-EDXRF this can be made on larger samples without preparation of thin sections.
Optimal Pulse Processing, Pile-Up Decomposition, and Applications of Silicon Drift Detectors at LCLS
Blaj, G.; Kenney, C. J.; Dragone, A.; ...
2017-10-11
Silicon drift detectors (SDDs) revolutionized spectroscopy in fields as diverse as geology and dentistry. For a subset of experiments at ultrafast, X-ray free-electron lasers (FELs), SDDs can make substantial contributions. Often the unknown spectrum is interesting, carrying science data, or the background measurement is useful to identify unexpected signals. Many measurements involve only several discrete photon energies known a priori, allowing single-event decomposition of pile-up and spectroscopic photon counting. We designed a pulse function and demonstrated that the signal amplitude (i.e., proportional to the detected energy and obtained from fitting with the pulse function), rise time, and pulse height aremore » interrelated, and at short peaking times, the pulse height and pulse area are not optimal estimators for detected energy; instead, the signal amplitude and rise time are obtained for each pulse by fitting, thus removing the need for pulse shaping. By avoiding pulse shaping, rise times of tens of nanoseconds resulted in reduced pulse pile-up and allowed decomposition of remaining pulse pile-up at photon separation times down to hundreds of nanoseconds while yielding time-of-arrival information with the precision of 10 ns. Waveform fitting yields simultaneously high energy resolution and high counting rates (two orders of magnitude higher than current digital pulse processors). At pulsed sources or high photon rates, photon pile-up still occurs. We showed that pile-up spectrum fitting is relatively simple and preferable to pile-up spectrum deconvolution. We then developed a photon pile-up statistical model for constant intensity sources, extended it to variable intensity sources (typical for FELs), and used it to fit a complex pileup spectrum. We subsequently developed a Bayesian pile-up decomposition method that allows decomposing pile-up of single events with up to six photons from six monochromatic lines with 99% accuracy. The usefulness of SDDs will continue into the X-ray FEL era of science. Their successors, the ePixS hybrid pixel detectors, already offer hundreds of pixels, each with a similar performance to an SDD, in a compact, robust and affordable package.« less
Optimal Pulse Processing, Pile-Up Decomposition, and Applications of Silicon Drift Detectors at LCLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blaj, G.; Kenney, C. J.; Dragone, A.
Silicon drift detectors (SDDs) revolutionized spectroscopy in fields as diverse as geology and dentistry. For a subset of experiments at ultrafast, X-ray free-electron lasers (FELs), SDDs can make substantial contributions. Often the unknown spectrum is interesting, carrying science data, or the background measurement is useful to identify unexpected signals. Many measurements involve only several discrete photon energies known a priori, allowing single-event decomposition of pile-up and spectroscopic photon counting. We designed a pulse function and demonstrated that the signal amplitude (i.e., proportional to the detected energy and obtained from fitting with the pulse function), rise time, and pulse height aremore » interrelated, and at short peaking times, the pulse height and pulse area are not optimal estimators for detected energy; instead, the signal amplitude and rise time are obtained for each pulse by fitting, thus removing the need for pulse shaping. By avoiding pulse shaping, rise times of tens of nanoseconds resulted in reduced pulse pile-up and allowed decomposition of remaining pulse pile-up at photon separation times down to hundreds of nanoseconds while yielding time-of-arrival information with the precision of 10 ns. Waveform fitting yields simultaneously high energy resolution and high counting rates (two orders of magnitude higher than current digital pulse processors). At pulsed sources or high photon rates, photon pile-up still occurs. We showed that pile-up spectrum fitting is relatively simple and preferable to pile-up spectrum deconvolution. We then developed a photon pile-up statistical model for constant intensity sources, extended it to variable intensity sources (typical for FELs), and used it to fit a complex pileup spectrum. We subsequently developed a Bayesian pile-up decomposition method that allows decomposing pile-up of single events with up to six photons from six monochromatic lines with 99% accuracy. The usefulness of SDDs will continue into the X-ray FEL era of science. Their successors, the ePixS hybrid pixel detectors, already offer hundreds of pixels, each with a similar performance to an SDD, in a compact, robust and affordable package.« less
Ulahannan, Rajeev T; Panicker, C Yohannan; Varghese, Hema Tresa; Musiol, Robert; Jampilek, Josef; Van Alsenoy, Christian; War, Javeed Ahmad; Al-Saadi, Abdulaziz A
2015-01-01
FT-IR and FT-Raman spectra of (2E)-N-(4-chloro-2-oxo-1,2-dihydroquinolin-3-yl)-3-phenylprop-2-enamide were recorded and analyzed experimentally and theoretically. The synthesis, (1)H NMR and PES scan results are also discussed. Nonlinear optical behavior of the examined molecule was investigated by the determination of first hyperpolarizability. The calculated HOMO and LUMO energies show the chemical activity of the molecule. The stability of the molecule arising from hyper-conjugative interaction and charge delocalization has been analyzed using NBO analysis. From the MEP it is evident that the negative charge covers the carbonyl group and the positive region is over the NH group. The calculated geometrical parameters (SDD) are in agreement with that of similar derivatives. Molecular docking simulations against targets from Mycobacterium tuberculosis are reported and the results suggest that the compound might exhibit inhibitory activity against PknB. Copyright © 2015 Elsevier B.V. All rights reserved.
Waste receiving and processing plant control system; system design description
DOE Office of Scientific and Technical Information (OSTI.GOV)
LANE, M.P.
1999-02-24
The Plant Control System (PCS) is a heterogeneous computer system composed of numerous sub-systems. The PCS represents every major computer system that is used to support operation of the Waste Receiving and Processing (WRAP) facility. This document, the System Design Description (PCS SDD), includes several chapters and appendices. Each chapter is devoted to a separate PCS sub-system. Typically, each chapter includes an overview description of the system, a list of associated documents related to operation of that system, and a detailed description of relevant system features. Each appendice provides configuration information for selected PCS sub-systems. The appendices are designed asmore » separate sections to assist in maintaining this document due to frequent changes in system configurations. This document is intended to serve as the primary reference for configuration of PCS computer systems. The use of this document is further described in the WRAP System Configuration Management Plan, WMH-350, Section 4.1.« less
Laser countermeasures for commercial airlines
NASA Astrophysics Data System (ADS)
Keirstead, Burt
2005-05-01
Since the attempted shoot down of an Israeli airliner departing from Mombasa, Kenya in November of 2002, there has been heightened concern that Al Qaeda, or other terrorist factions, will use shoulder-fired heat seeking missiles as part of their tactics. These weapons, known more formally as man-portable air defense systems, or MANPADS, have been widely proliferated, are easy to conceal and deploy, and can be purchased on the black market for as little as $10,000. Recognizing that MANPADS pose a potential threat to commercial airplanes throughout the world, the Department of Homeland Security (DHS) is executing a system design and development (SDD) program to evaluate the viability of missile countermeasures that would be installed on commercial airplanes. This paper provides an overview of the MANPADS threat, a discussion of associated countermeasure requirements for systems installed on commercial airplanes, and a description of a laser countermeasure system that is being prototyped and demonstrated as part of the DHS Counter-MANPADS program.
Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization
NASA Astrophysics Data System (ADS)
Xu, J.; Sisniega, A.; Zbijewski, W.; Dang, H.; Stayman, J. W.; Wang, X.; Foos, D. H.; Aygun, N.; Koliatsos, V. E.; Siewerdsen, J. H.
2016-04-01
Detection of acute intracranial hemorrhage (ICH) is important for diagnosis and treatment of traumatic brain injury, stroke, postoperative bleeding, and other head and neck injuries. This paper details the design and development of a cone-beam CT (CBCT) system developed specifically for the detection of low-contrast ICH in a form suitable for application at the point of care. Recognizing such a low-contrast imaging task to be a major challenge in CBCT, the system design began with a rigorous analysis of task-based detectability including critical aspects of system geometry, hardware configuration, and artifact correction. The imaging performance model described the three-dimensional (3D) noise-equivalent quanta using a cascaded systems model that included the effects of scatter, scatter correction, hardware considerations of complementary metal-oxide semiconductor (CMOS) and flat-panel detectors (FPDs), and digitization bit depth. The performance was analyzed with respect to a low-contrast (40-80 HU), medium-frequency task representing acute ICH detection. The task-based detectability index was computed using a non-prewhitening observer model. The optimization was performed with respect to four major design considerations: (1) system geometry (including source-to-detector distance (SDD) and source-to-axis distance (SAD)); (2) factors related to the x-ray source (including focal spot size, kVp, dose, and tube power); (3) scatter correction and selection of an antiscatter grid; and (4) x-ray detector configuration (including pixel size, additive electronics noise, field of view (FOV), and frame rate, including both CMOS and a-Si:H FPDs). Optimal design choices were also considered with respect to practical constraints and available hardware components. The model was verified in comparison to measurements on a CBCT imaging bench as a function of the numerous design parameters mentioned above. An extended geometry (SAD = 750 mm, SDD = 1100 mm) was found to be advantageous in terms of patient dose (20 mGy) and scatter reduction, while a more isocentric configuration (SAD = 550 mm, SDD = 1000 mm) was found to give a more compact and mechanically favorable configuration with minor tradeoff in detectability. An x-ray source with a 0.6 mm focal spot size provided the best compromise between spatial resolution requirements and x-ray tube power. Use of a modest anti-scatter grid (8:1 GR) at a 20 mGy dose provided slight improvement (~5-10%) in the detectability index, but the benefit was lost at reduced dose. The potential advantages of CMOS detectors over FPDs were quantified, showing that both detectors provided sufficient spatial resolution for ICH detection, while the former provided a potentially superior low-dose performance, and the latter provided the requisite FOV for volumetric imaging in a centered-detector geometry. Task-based imaging performance modeling provides an important starting point for CBCT system design, especially for the challenging task of ICH detection, which is somewhat beyond the capabilities of existing CBCT platforms. The model identifies important tradeoffs in system geometry and hardware configuration, and it supports the development of a dedicated CBCT system for point-of-care application. A prototype suitable for clinical studies is in development based on this analysis.
BH-DFTB/DFT calculations for iron clusters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aktürk, Abdurrahman; Sebetci, Ali, E-mail: asebetci@mevlana.edu.tr
2016-05-15
We present a study on the structural, electronic, and magnetic properties of Fe{sub n}(n = 2 − 20) clusters by performing density functional tight binding (DFTB) calculations within a basin hopping (BH) global optimization search followed by density functional theory (DFT) investigations. The structures, total energies and total spin magnetic moments are calculated and compared with previously reported theoretical and experimental results. Two basis sets SDD with ECP and 6-31G** are employed in the DFT calculations together with BLYP GGA exchange-correlation functional. The results indicate that the offered BH-DFTB/DFT strategy collects all the global minima of which different minima havemore » been reported in the previous studies by different groups. Small Fe clusters have three kinds of packing; icosahedral (Fe{sub 9−13}), centered hexagonal antiprism (Fe{sub 14−17}, Fe{sub 20}), and truncated decahedral (Fe{sub 17(2)}, Fe{sub 18−19}). It is obtained in a qualitative agreement with the time of flight mass spectra that the magic numbers for the small Fe clusters are 7, 13, 15, and 19 and with the collision induced dissociation experiments that the sizes 6, 7, 13, 15, and 19 are thermodynamically more stable than their neighboring sizes. The spin magnetic moment per atom of Fe{sub n}(n = 2 − 20) clusters is between 2.4 and 3.6 μ{sub B} for the most of the sizes. The antiferromagnetic coupling between the central and the surface atoms of the Fe{sub 13} icosahedron, which have already been reported by experimental and theoretical studies, is verified by our calculations as well. The quantitative disagreements between the calculations and measurements of the magnetic moments of the individual sizes are still to be resolved.« less
DFT Studies on Interaction between Lanthanum and Hydroxyamide
NASA Astrophysics Data System (ADS)
Pati, Anindita; Kundu, T. K.; Pal, Snehanshu
2018-03-01
Extraction and separation of individual rare earth elements has been a challenge as they are chemically very similar. Solvent extraction is the most suitable way for extraction of rare earth elements. Acidic, basic, neutral, chelating are the major classes of extractants for solvent extraction of rare earth elements. The coordination complex of chelating extractants is very selective with positively charged metal ion. Hence they are widely used. Hydroxyamide is capable of forming chelates with metal cations. In this present study interactions of hydroxyamide ligand with lanthanum have been investigated using density functional theory (DFT). Two different functional such as raB97XD and B3LYP are applied along with 6-31+G(d,p) basis set for carbon, nitrogen, hydrogen and SDD basis set for lanthanum. Stability of formed complexes has been evaluated based on calculated interaction energies and solvation energies. Frontier orbital (highest occupied molecular orbital or HOMO and lowest unoccupied molecular orbital or LUMO) energies of the molecule have also been calculated. Electronegativity, chemical hardness, chemical softness and chemical potential are also determined for these complexes to get an idea about the reactivity. From the partial charge distribution it is seen that oxygen atoms in hydroxyamide have higher negative charge. The double bonded oxygen atom present in the hydroxyamide structure has higher electron density and so it forms bond with lanthanum but the singly bonded oxygen atom in the hydroxyamide structure is weaker donor atom and so it is less available for interaction with lanthanum.
X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics.
Rácz, R; Biri, S; Pálinkás, J; Mascali, D; Castro, G; Caliri, C; Romano, F P; Gammino, S
2016-02-01
Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.
Phosphorylation-induced changes in the energetic frustration in human Tank binding kinase 1.
Husain, Shahrukh; Kumar, Vijay; Hassan, Md Imtaiyaz
2018-07-14
Tank binding kinase 1 (TBK-1) plays an important role in immunity, inflammation, autophagy, cell growth and proliferation. Nevertheless, a key molecular and structural detail of TBK-1 phosphorylation and activation has been largely unknown. Here we investigated the energy landscape of phosphorylated (active) and unphosphorylated (inactive) forms of human TBK-1 to characterize the interplay between phosphorylation and local frustration. By employing the algorithm equipped with energy function and implemented in Frustratometer web-server (http://www.frustratometer.tk), we quantify the role of frustration in the activation of TBK-1. Accordingly, the conformational changes were observed in phosphoregulated active and inactive TBK-1. Substantial changes in frustration, flexibility and interatomic motions were observed among different forms of TBK-1. Structurally rigid kinase domain constitutes a minimally frustrated hub in the core of the catalytic domain, and highly frustrated clusters mainly at the C-lobe might enable the conformational transitions during activation. Also, a large network of highly frustrated interactions is found in the SDD domain of TBK-1 involved in protein-protein interactions and dimerization. The contact maps of the activation loop and α-C helix of kinase domain showed significant changes upon phosphorylation. Cross correlation analysis indicate that both intra and inter subunit correlated motions increases with phosphorylation of TBK-1. Phosphorylation thus introduces subtle changes in long-range contacts that might lead to significant conformational change of TBK-1. Copyright © 2018 Elsevier Ltd. All rights reserved.
Kumamoto, Akihito; Kogure, Toshihiro; Raimbourg, Hugues; Ikuhara, Yuichi
2014-11-01
Dislocations, one-dimensional lattice defects, appear as a microscopic phenomenon while they are formed in silicate minerals by macroscopic dynamics of the earth crust such as shear stress. To understand ductile deformation mechanisms of silicates, atomic structures of the dislocations have been examined using transmission electron microscopy (TEM). Among them, it has been proposed that {100}<001> primary slip system of orthopyroxene (Opx) is dissociated into partial dislocations, and a stacking fault with the clinopyroxene (Cpx) structure is formed between the dislocations. This model, however, has not been determined completely due to the complex structures of silicates. Scanning transmission electron microscopy (STEM) has a potential to determine the structure of dislocations with single-atomic column sensitivity, particularly by using high-angle annular dark field (HAADF) and annular bright field (ABF) imaging with a probing aberration corrector.[1] Furthermore, successive analyses from light microscopy to atom-resolved STEM have been achieved by focused ion beam (FIB) sampling techniques.[2] In this study, we examined dislocation arrays at a low-angle grain boundary of ∼1° rotation about the b-axis in natural deformed Opx using a simultaneous acquisition of HAADF/ABF (JEM-ARM200F, JEOL) equipped with 100 mm2 silicon drift detector (SDD) for energy dispersive X-ray spectroscopy (EDS). Figure 1 shows averaged STEM images viewed along the b- axis of Opx extracted from repeating units. HAADF provides the cation-site arrangement, and ABF distinguishes the difference of slightly rotated SiO4 tetrahedron around the a- axis. This is useful to distinguish the change of stacking sequence between the partial dislocations. Two types of stacking faults with Cpx and protopyroxene (Ppx) structures were identified between three partial dislocations. Furthermore, Ca accumulation in M2 (Fe) site around the stacking faults was detected by STEM-EDS. Interestingly, Ca is distributed not only in these stacking faults but also Opx matrix around the faults. jmicro;63/suppl_1/i17/DFU063F1F1DFU063F1Fig. 1. (a) HAADF and (b) ABF of Opx view of [010] direction with inset simulation images and models of its unit cell (a = 0.52, c = 1.83 nm). © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Rahman, Md Sajjadur; Hossain, Syed Mohammod; Rahman, Mir Tamzid; Halim, Mohammad A; Ishtiak, Mohammad Niaz; Kabir, Mahbub
2017-11-08
Leaching of toxic metals from fertilizers is a growing concern in an agricultural country like Bangladesh due to the serious consequences in health and food chain. Fertilizers used in farming fields and nurseries (plant sales outlet) in the mid-southern part of Bangladesh were collected for the determination of toxic metals. This study employed the neutron activation method and a relative standardization approach. Three standard/certified reference materials, namely NIST coal fly ash 1633b, IAEA-Soil-7, and IAEA-SL-1 (lake sediment), were considered for elemental quantification. Concentration of As (2.63-16.73 mg/kg), Cr (40.93-261.77 mg/kg), Sb (0.47-63.58 mg/kg), Th (1.44-19.16 mg/kg), and U (1.90-209.41 mg/kg) were determined in fertilizers. High concentrations of Cr, Sb, and U were detected in some compost and phosphate fertilizers (TSP and diammonium phosphate (DAP)) in comparison with the IAEA/European market standard and other studies. Quantum mechanical calculations were performed to understand the molecular level interaction of CrO 3 , Sb 2 O 3 , and AsO 3 , with DAP by employing density functional theory with the B3LYP/SDD level of theory. Our results indicated that CrO 3 and Sb 2 O 3 have strong binding affinity with DAP compared to AsO 3 , which supports the experimental results. These compounds attached to the phosphate group through covalent-like bonding with oxygen. The frontier molecular orbital calculation indicated that HOMO-LUMO gap of the AsO 3 -DAP (5.46 eV) and Sb 2 O 3 -DAP (6.48 eV) complexes are relatively lower than the CrO 3 -DAP, which indicates that As and Sb oxides are chemically more prone to attach with the phosphate group of DAP fertilizer.
SU-C-202-07: Protocol and Hardware for Improved Flood Field Calibration of TrueBeam FFF Cine Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adamson, J; Faught, A; Yin, F
2016-06-15
Purpose: Flattening filter free photon energies are commonly used for high dose treatments such as SBRT, where localization accuracy is essential. Often, MV cine imaging may be employed to verify correct localization. TrueBeam Electronic Portal Imaging Devices (EPIDs) equipped with the 40×30cm{sup 2} Image Detection Unit (IDU) are prone to image saturation at the image center especially for higher dose rates. While saturation often does not occur for cine imaging during treatment because the beam is attenuated by the patient, the flood field calibration is affected when the standard calibration procedure is followed. Here we describe the hardware and protocolmore » to achieve improved image quality for this model of TrueBeam EPID. Methods: A stainless steel filter of uniform thickness was designed to have sufficient attenuation to avoid panel saturation for both 6XFFF and 10XFFF at the maximum dose rates (1400 MU/min & 2400 MU/min, respectively). The cine imaging flood field calibration was then acquired with the filter in place for the FFF energies under the standard calibration geometry (SDD=150cm). Image quality during MV cine was assessed with & without the modified flood field calibration using a low contrast resolution phantom and an anthropomorphic phantom. Results: When the flood field is acquired using the standard procedure (no filter in place), a pixel gain artifact is clearly present in the image center (r=3cm for 10XFFF at 2400 MU/min) which appears similar to and may be mis-attributed to panel saturation in the subject image. The artifact obscured all low contrast inserts at the image center and was also visible on the anthropomorphic phantom. Using the filter for flood field calibration eliminated the artifact. Conclusion: Use of a modified flood field calibration procedure improves image quality for cine MV imaging with TrueBeams equipped with the 40×30cm{sup 2} IDU.« less
SU-F-T-555: Accurate Stereotactic Cone TMRs Converted from PDDs Scanned with Ray Trace
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, H; Zhong, H; Qin, Y
Purpose: To investigate whether the accuracy of TMRs for stereotactic cones converted from PDDs scanned with Ray Trace can be improved, when compared against the TMRs converted from the traditional PDDs. Methods: Ray Trace measurement in Sun Nuclear 3D Scanner is for accurate scan of small field PDDs. The system detects the center of field at two depths, for example, at 3 and 20 cm in our study, and then performs scan along the line passing the two centers. With both Ray Trace and the traditional method, PDDs for conical cones of 4, 5, 7.5, 10, 12.5, 15, and 17.5more » mm diameter (jaws set to 5×5 cm) were obtained for 6X FFF and 10X FFF energies on a Varian Edge linac, using Edge detectors. The formalism of converting PDD to TMR given in Khan’s book (4th Edition, p.161) was applied. Sp values at dmax were obtained by measuring cone Scp and Sc. Continuous direct measurement of TMR by filling/draining water to/from the tank and spot measurement by moving the tank and detector were also performed with the same equipment, using 100 cm SDD. Results: For 6XFFF energy and all the cones, TMRs converted from Ray Trace were very close to the continuous and spot measurement, while TMRs converted from traditional PDDs had larger deviation. Along the central axis beyond dmax, 1.7% of TMR data points calculated from Ray Trace had more 3% deviation from measurement, with maximal deviation of 5.2%. Whereas, 34% of TMR points calculated from traditional PDDs had more than 3% deviation, with maximum of 5.7%. In this initial study, Ray Trace scans for 10XFFF beam were noisy, further measurement is warranted. Conclusion: The Ray Trace could improve the accuracy of PDDs measurement and the calculated TMRs for stereotactic cones, which was within 3% of the measured TMRs.« less
NASA Astrophysics Data System (ADS)
Saravanan, A. V. Sai; Abishek, B.; Anantharaj, R.
2018-04-01
The fundamental natures of the molecular level interaction and charge transfer between specific radioactive elements and ionic liquids of 1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide ([BMIM]+[NTf2]-), 1-Butyl-3-methylimidazolium ethylsulfate ([BMIM]+[ES]-) and 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]+[BF4]-) were investigated utilising HF theory and B3LYP hybrid DFT. The ambiguity in reaction mechanism of the interacting species dictates to employ Effective Core Potential (ECP) basis sets such as UGBS, SDD, and SDDAll to account for the relativistic effects of deep core electrons in the system involving potential, heavy and hazardous radioactive elements present in nuclear waste. The SCF energy convergence of each system validates the characterisation of the molecular orbitals as a linear combination of atomic orbitals utilising fixed MO coefficients and the optimized geometry of each system is visualised based on which Mulliken partial charge analysis is carried out to account for the polarising behaviour of the radioactive element and charge transfer between the IL phase by comparison with the bare IL species.
Reimagining Childhood: Responding to the Challenge Presented by Severe Developmental Disability.
Salter, Erica K
2017-09-01
Through an exploration of the experience of severe and profound intellectual disability, this essay will attempt to expose the predominant, yet usually obscured, medical anthropology of the child and examine its effects on pediatric bioethics. I will argue that both modern western society and modern western medicine do, actually, have a robust notion of the child, a notion which can find its roots in three influential thinkers: Aristotle, Immanuel Kant and Jean Piaget. Together, these philosophers offer us a compelling vision: the child is primarily a future rational, autonomous adult. While this tacit understanding has arguably widespread effects on such things as our concept of good parenting, of proper schooling, and so on, I will focus on the effect is has on the treatment of children with severe developmental disabilities. When examined in light of this population, the dominant medical anthropology of the child will be shown to be deficient. Instead, I argue for an expansion-indeed, a full reimagining-of our notions of childhood, not only to re-infuse dignity into the lives of children with SDD, but to better represent the goods of childhood, generally.
Monte Carlo study of a 60Co calibration field of the Dosimetry Laboratory Seibersdorf.
Hranitzky, C; Stadtmann, H
2007-01-01
The gamma radiation fields of the reference irradiation facility of the Dosimetry Laboratory Seibersdorf with collimated beam geometry are used for calibrating radiation protection dosemeters. A close-to-reality simulation model of the facility including the complex geometry of a 60Co source was set up using the Monte Carlo code MCNP. The goal of this study is to characterise the radionuclide gamma calibration field and resulting air-kerma distributions inside the measurement hall with a total of 20 m in length. For the whole range of source-detector-distances (SDD) along the central beam axis, simulated and measured relative air-kerma values are within +/-0.6%. Influences on the accuracy of the simulation results are investigated, including e.g., source mass density effects or detector volume dependencies. A constant scatter contribution from the lead ring-collimator of approximately 1% and an increasing scatter contribution from the concrete floor for distances above 7 m are identified, resulting in a total air-kerma scatter contribution below 5%, which is in accordance to the ISO 4037-1 recommendations.
Alp, Sehnaz; Sancak, Banu; Hascelik, Gulsen; Arikan, Sevtap
2010-11-01
We investigated the incidence of trailing growth with fluconazole in 101 clinical Candida isolates (49 C. albicans and 52 C. tropicalis) and tried to establish the convenient susceptibility testing method and medium for fluconazole minimum inhibitory concentration (MIC) determination. MICs were determined by CLSI M27-A2 broth microdilution (BMD) and Etest methods on RPMI-1640 agar supplemented with 2% glucose (RPG) and on Mueller-Hinton agar supplemented with 2% glucose and 0.5 μg ml(-1) methylene blue (GMB). BMD and Etest MICs were read at 24 and 48 h, and susceptibility categories were compared. All isolates were determined as susceptible with BMD, Etest-RPG and Etest-GMB at 24 h. While all isolates were interpreted as susceptible at 48 h on Etest-RPG and Etest-GMB, one C. albicans isolate was interpreted as susceptible-dose dependent (S-DD) and two C. tropicalis isolates were interpreted as resistant with BMD. On Etest-RPG, trailing growth caused widespread microcolonies within the inhibition zone and resulted in confusion in MIC determination. On Etest-GMB, because of the nearly absence of microcolonies within the zone of inhibition, MICs were evaluated more easily. We conclude that, for the determination of fluconazole MICs of trailing Candida isolates, the Etest method has an advantage over BMD and can be used along with this reference method. Moreover, GMB appears more beneficial than RPG for the fluconazole Etest. © 2009 Blackwell Verlag GmbH.
X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rácz, R., E-mail: rracz@atomki.hu; Biri, S.; Pálinkás, J.
Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago.more » The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.« less
Ulahannan, Rajeev T; Panicker, C Yohannan; Varghese, Hema Tresa; Musiol, Robert; Jampilek, Josef; Van Alsenoy, Christian; War, Javeed Ahmad; Srivastava, S K
2015-01-01
The optimized molecular structure, vibrational frequencies, corresponding vibrational assignments of 2-[(E)-2-(2-bromophenyl)ethenyl]quinoline-6-carboxylic acid have been investigated experimentally and theoretically using Gaussian09 software package. Potential energy distribution of the normal modes of vibrations was done using GAR2PED program. (1)H NMR chemical shifts calculations were carried out by using B3LYP functional with SDD basis set. The HOMO and LUMO analysis is used to determine the charge transfer within the molecule. The stability of the molecule arising from hyper-conjugative interaction and charge delocalization has been analyzed using NBO analysis. MEP was performed by the DFT method and the predicted infrared intensities and Raman activities have also been reported. The calculated geometrical parameters are in agreement with that of similar derivatives. The title compound forms a stable complex with PknB as is evident from the binding affinity values and the molecular docking results suggest that the compound might exhibit inhibitory activity against PknB and this may result in development of new anti-tuberculostic agents. Copyright © 2015 Elsevier B.V. All rights reserved.
Rating prediction using textual reviews
NASA Astrophysics Data System (ADS)
NithyaKalyani, A.; Ushasukhanya, S.; Nagamalleswari, TYJ; Girija, S.
2018-04-01
Information today is present in the form of opinions. Two & a half quintillion bytes are exchanged today in Internet everyday and a large amount consists of people’s speculation and reflection over an issue. It is the need of the hour to be able to mine this information that is presented to us. Sentimental analysis refers to mining of this raw information to make sense. The discipline of opinion mining has seen a lot of encouragement in the past few years augmented by involvement of social media like Instagram, Facebook, and twitter. The hidden message in this web of information is useful in several fields such as marketing, political polls, product review, forecast market movement, Identifying detractor and promoter. In this endeavor, we introduced sentiment rating system for a particular text or paragraph to determine the opinions polarity. Firstly we resolve the searching problem, tokenization, classification, and reliable content identification. Secondly we extract probability for given text or paragraph for both positive & negative sentiment value using naive bayes classifier. At last we use sentiment dictionary (SD), sentiment degree dictionary (SDD) and negation dictionary (ND) for more accuracy. Later we blend all above mentioned factor into given formula to find the rating for the review.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rhinefrank, Kenneth; Lamb, Bradford; Prudell, Joseph
This Project aims to satisfy objectives of the DOE’s Water Power Program by completing a system detailed design (SDD) and other important activities in the first phase of a utility-scale grid-connected ocean wave energy demonstration. In early 2012, Columbia Power (CPwr) had determined that further cost and performance optimization was necessary in order to commercialize its StingRAY wave energy converter (WEC). CPwr’s progress toward commercialization, and the requisite technology development path, were focused on transitioning toward a commercial-scale demonstration. This path required significant investment to be successful, and the justification for this investment required improved annual energy production (AEP) andmore » lower capital costs. Engineering solutions were developed to address these technical and cost challenges, incorporated into a proposal to the US Department of Energy (DOE), and then adapted to form the technical content and statement of project objectives of the resulting Project (DE-EE0005930). Through Project cost-sharing and technical collaboration between DOE and CPwr, and technical collaboration with Oregon State University (OSU), National Renewable Energy Lab (NREL) and other Project partners, we have demonstrated experimentally that these conceptual improvements have merit and made significant progress towards a certified WEC system design at a selected and contracted deployment site at the Wave Energy Test Site (WETS) at the Marine Corps Base in Oahu, HI (MCBH).« less
Sensory processing disorder: any of a nurse practitioner's business?
Byrne, Mary W
2009-06-01
Children who exhibit the confusing symptom patterns associated with sensory processing deficits are often seen first by primary care providers, including family and pediatric nurse practitioners (NPs). The purpose of this article is to alert NPs to the state of the science for these disorders and to the roles NPs could play in filling the knowledge gaps in assessment, treatment, education, and research. Literature searches using PubMed and MedLine databases and clinical practice observations. Sensory integration disorders have only begun to be defined during the past 35 years. They are not currently included in the DSM IV standard terminology, and are not yet substantively incorporated into most health disciplines' curricula or practice, including those of the NP. NPs are in a unique position to test hypothesized terminology for Sensory Processing Disorder (SPD) by contributing precise clinical descriptions of children who match as well as deviate from the criteria for three proposed diagnostic groups: Sensory Modulation Disorder (SMD), Sensory Discrimination Disorder (SDD), and Sensory-Based Motor Disorder (SBMD). Beyond the SPD diagnostic debate, for children with sensory deficit patterns the NP role can incorporate participating in interdisciplinary treatment plans, refining differential diagnoses, providing frontline referral and support for affected children and their families, and making both secondary prevention and critical causal research possible through validation of consistently accepted diagnostic criteria.
Information Mining of Spatio-Temporal Evolution of Lakes Based on Multiple Dynamic Measurements
NASA Astrophysics Data System (ADS)
Feng, W.; Chen, J.
2017-09-01
Lakes are important water resources and integral parts of the natural ecosystem, and it is of great significance to study the evolution of lakes. The area of each lake increased and decreased at the same time in natural condition, only but the net change of lakes' area is the result of the bidirectional evolution of lakes. In this paper, considering the effects of net fragmentation, net attenuation, swap change and spatial invariant part in lake evolution, a comprehensive evaluation indexes of lake dynamic evolution were defined,. Such degree contains three levels of measurement: 1) the swap dynamic degree (SDD) reflects the space activity of lakes in the study period. 2) the attenuation dynamic degree (ADD) reflects the net attenuation of lakes into non-lake areas. 3) the fragmentation dynamic degree (FDD) reflects the trend of lakes to be divided and broken into smaller lakes. Three levels of dynamic measurement constitute the three-dimensional "Swap - attenuation - fragmentation" dynamic evolution measurement system of lakes. To show its effectiveness, the dynamic measurement was applied to lakes in Jianghan Plain, the middle Yangtze region of China for a more detailed analysis of lakes from 1984 to 2014. In combination with spatial-temporal location characteristics of lakes, the hidden information in lake evolution in the past 30 years can be revealed.
MIXS on BepiColombo and its DEPFET based focal plane instrumentation
NASA Astrophysics Data System (ADS)
Treis, J.; Andricek, L.; Aschauer, F.; Heinzinger, K.; Herrmann, S.; Hilchenbach, M.; Lauf, T.; Lechner, P.; Lutz, G.; Majewski, P.; Porro, M.; Richter, R. H.; Schaller, G.; Schnecke, M.; Schopper, F.; Soltau, H.; Stefanescu, A.; Strüder, L.; de Vita, G.
2010-12-01
Focal plane instrumentation based on DEPFET Macropixel devices, being a combination of the Detector-Amplifier structure DEPFET with a silicon drift chamber (SDD), has been proposed for the MIXS (Mercury Imaging X-ray Spectrometer) instrument on ESA's Mercury exploration mission BepiColombo. MIXS images X-ray fluorescent radiation from the Mercury surface with a lightweight X-ray mirror system on the focal plane detector to measure the spatially resolved element abundance in Mercury's crust. The sensor needs to have an energy resolution better than 200 eV FWHM at 1 keV and is required to cover an energy range from 0.5 to 10 keV, for a pixel size of 300×300μm2. Main challenges for the instrument are radiation damage and the difficult thermal environment in the mercury orbit. The production of the first batch of flight devices has been finished at the MPI semiconductor laboratory. Prototype modules have been assembled to verify the electrical properties of the devices; selected results are presented here. The prototype devices, Macropixel prototypes for the SIMBOL-X focal plane, are electrically fully compatible, but have a pixel size of 0.5×0.5 mm2. Excellent homogeneity and near Fano-limited energy resolution at high readout speeds have been observed on these devices.
Elshazly, M. O.; Abd El-Rahman, Sahar S.; Morgan, Ashraf M.; Ali, Merhan E.
2015-01-01
This study was conducted to investigate the possible protective effect of Spirulina platensis against chromium-induced nephrotoxicity. A total of 36 adult male Sprague-Dawley rats were divided into 4 equal groups (Gps). Gp1 served as control, rats of Gps 2, 3, and 4 were exposed to Spirulina platensis (300 mg/kg b.wt per os) and sodium dichromate dihydrate (SDD) via drinking water at concentration of 520 mg /l respectively. Chromium administration caused alterations in the renal function markers as evidenced by significant increase of blood urea and creatinine levels accompanied with significant increase in kidney’s chromium residues and MDA level as well as decreased catalase activity and glutathion content in kidney tissue. Histologically, Cr provoked deleterious changes including: vascular congestion, wide spread tubular epithelium necrobiotic changes, atrophy of glomerular tuft and proliferative hyperplasia. The latter was accompanied with positive PCNA expression in kidney tissues as well as DNA ploidy interpretation of major cellular population of degenerated cells, appearance of tetraploid cells, high proliferation index and high DNA index. Morphometrical measurements revealed marked glomerular and tubular lumen alterations. On contrary, spirulina co-treatment with Cr significantly restored the histopathological changes, antioxidants and renal function markers and all the previously mentioned changes as well. PMID:26029926
Elshazly, M O; Abd El-Rahman, Sahar S; Morgan, Ashraf M; Ali, Merhan E
2015-01-01
This study was conducted to investigate the possible protective effect of Spirulina platensis against chromium-induced nephrotoxicity. A total of 36 adult male Sprague-Dawley rats were divided into 4 equal groups (Gps). Gp1 served as control, rats of Gps 2, 3, and 4 were exposed to Spirulina platensis (300 mg/kg b.wt per os) and sodium dichromate dihydrate (SDD) via drinking water at concentration of 520 mg /l respectively. Chromium administration caused alterations in the renal function markers as evidenced by significant increase of blood urea and creatinine levels accompanied with significant increase in kidney's chromium residues and MDA level as well as decreased catalase activity and glutathion content in kidney tissue. Histologically, Cr provoked deleterious changes including: vascular congestion, wide spread tubular epithelium necrobiotic changes, atrophy of glomerular tuft and proliferative hyperplasia. The latter was accompanied with positive PCNA expression in kidney tissues as well as DNA ploidy interpretation of major cellular population of degenerated cells, appearance of tetraploid cells, high proliferation index and high DNA index. Morphometrical measurements revealed marked glomerular and tubular lumen alterations. On contrary, spirulina co-treatment with Cr significantly restored the histopathological changes, antioxidants and renal function markers and all the previously mentioned changes as well.
Crystal Structure of a Human IκB Kinase β Asymmetric Dimer
Liu, Shenping; Misquitta, Yohann R.; Olland, Andrea; Johnson, Mark A.; Kelleher, Kerry S.; Kriz, Ron; Lin, Laura L.; Stahl, Mark; Mosyak, Lidia
2013-01-01
Phosphorylation of inhibitor of nuclear transcription factor κB (IκB) by IκB kinase (IKK) triggers the degradation of IκB and migration of cytoplasmic κB to the nucleus where it promotes the transcription of its target genes. Activation of IKK is achieved by phosphorylation of its main subunit, IKKβ, at the activation loop sites. Here, we report the 2.8 Å resolution crystal structure of human IKKβ (hIKKβ), which is partially phosphorylated and bound to the staurosporine analog K252a. The hIKKβ protomer adopts a trimodular structure that closely resembles that from Xenopus laevis (xIKKβ): an N-terminal kinase domain (KD), a central ubiquitin-like domain (ULD), and a C-terminal scaffold/dimerization domain (SDD). Although hIKKβ and xIKKβ utilize a similar dimerization mode, their overall geometries are distinct. In contrast to the structure resembling closed shears reported previously for xIKKβ, hIKKβ exists as an open asymmetric dimer in which the two KDs are further apart, with one in an active and the other in an inactive conformation. Dimer interactions are limited to the C-terminal six-helix bundle that acts as a hinge between the two subunits. The observed domain movements in the structures of IKKβ may represent trans-phosphorylation steps that accompany IKKβ activation. PMID:23792959
Petraco, Ricardo; Sen, Sayan; Nijjer, Sukhjinder; Echavarria-Pinto, Mauro; Escaned, Javier; Francis, Darrel P; Davies, Justin E
2013-03-01
This study sought to evaluate the effects of fractional flow reserve (FFR) measurement variability on FFR-guided treatment strategy. Current appropriateness guidelines recommend the utilization of FFR to guide coronary revascularization based on a fixed cut-off of 0.8. This rigid approach does not take into account the intrinsic biological variability of a single FFR result and the clinical judgment of experienced interventional cardiologists. [corrected]. FFR reproducibility data from the landmark Deferral Versus Performance of PTCA in Patients Without Documented Ischemia (DEFER) trial was analyzed (two repeated FFR measurements in the same lesion, 10 min apart) and the standard deviation of the difference (SDD) between repeated measurements was calculated. The measurement certainty (probability that the FFR-guided revascularization strategy will not change if the test is repeated 10 min later) was subsequently established across the whole range of FFR values, from 0.2 to 1. Outside the [0.75 to 0.85] FFR range, measurement certainty of a single FFR result is >95%. However, closer to its cut-off, certainty falls to less than 80% within 0.77 to 0.83, reaching a nadir of 50% around 0.8. In clinical practice, that means that each time a single FFR value falls between 0.75 and 0.85, there is a chance that the FFR-derived revascularization recommendation will change if the measurement is repeated 10 min later, with this chance increasing the closer the FFR result is to 0.8. A measurement FFR gray-zone is found between 0.75 and 0.85]. Therefore, clinicians should make revascularization decisions based on broadened clinical judgment when a single FFR result falls within this uncertainty zone, particularly between 0.77 and 0.83, when measurement certainty falls to less than 80%. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
A wearable diffuse reflectance sensor for continuous monitoring of cutaneous blood content
NASA Astrophysics Data System (ADS)
Zakharov, P.; Talary, M. S.; Caduff, A.
2009-09-01
An optical diffuse reflectance sensor for characterization of cutaneous blood content and optimized for continuous monitoring has been developed as part of a non-invasive multisensor system for glucose monitoring. A Monte Carlo simulation of the light propagation in the multilayered skin model has been performed in order to estimate the optimal geometrical separation of the light source and detector for skin and underlying tissue. We have observed that the pathlength within the upper vascular plexus of the skin which defines the sensor sensitivity initially grows with increasing source-detector distance (SDD) before reaching a maximum at 3.5 mm and starts to decay with further increase. At the same time, for distances above 2.4 mm, the sensor becomes sensitive to muscle blood content, which decreases the specificity to skin perfusion monitoring. Thus, the SDDs in the range from 1.5 mm to 2.4 mm satisfy the requirements of sensor sensitivity and specificity. The hardware implementation of the system has been realized and tested in laboratory experiments with a venous occlusion procedure and in an outpatient clinical study in 16 patients with type 1 diabetes mellitus. For both testing procedures, the optical sensor demonstrated high sensitivity to perfusion change provoking events. The general build-up of cutaneous blood under the sensor has been observed which can be associated with pressure-induced vasodilation as a response to the sensor application.
NASA Astrophysics Data System (ADS)
Erkan kariper, Sultan; Sayin, Koray; Karakaş, Duran
2017-12-01
[Ru(bipy)2(CppH)]2+(1), [Ru(bipy)2(Cpp-NH-Hex-COOH)]2+(2), [Ru(dppz)2(CppH)]2+(3) and [Ru(dppz)2(Cpp-NH-Hex-COOH)]2+(4) were calculated by Hartree-Fock (HF), Density Functional Theory (DFT) hybrid B3LYP and Moller-Plesset Perturbation (MPn n = 2,3) theory method and CEP-4G, CEP-31G, CEP-121G, LANL2DZ, LANL2MB, SDD basic sets and a mixed basic set with the keyword GEN in gas phase and water. Structure parameters obtained from optimized structures were compared with experimental parameters. M062X/(6-31G(d))(CEP-4G) level was taken into account for the most appropriate calculation level. IR, UV-VIS and NMR spectrums were examined for structural characterization. The optimal structure was identified via structure parameters, IR, UV-VIS and NMR spectrums. For the most compatible structure, the highest molecular orbital energy (EHOMO) which one of the most effective chemical determiners on the antitumor activity of the complexes, the lowest molecular orbital energy (ELUMO), LUMO-HOMO energy gap, hardness (η), softness (σ), electronegativity (χ), chemical potential (μ), electrophilicity index (ω), molar volume (V), dipole moment (DM), total negative charge (TNC), enthalpy (H), entropy (S) and total energy (E) were calculated. The causes of anticancer activity of the complexes have been studied.
Climatic factors associated with amyotrophic lateral sclerosis: a spatial analysis from Taiwan.
Tsai, Ching-Piao; Tzu-Chi Lee, Charles
2013-11-01
Few studies have assessed the spatial association of amyotrophic lateral sclerosis (ALS) incidence in the world. The aim of this study was to identify the association of climatic factors and ALS incidence in Taiwan. A total of 1,434 subjects with the primary diagnosis of ALS between years 1997 and 2008 were identified in the national health insurance research database. The diagnosis was also verified by the national health insurance programme, which had issued and providing them with "serious disabling disease (SDD) certificates". Local indicators of spatial association were employed to investigate spatial clustering of age-standardised incidence ratios in the townships of the study area. Spatial regression was utilised to reveal any association of annual average climatic factors and ALS incidence for the 12-year study period. The climatic factors included the annual average time of sunlight exposure, average temperature, maximum temperature, minimum temperature, atmospheric pressure, rainfall, relative humidity and wind speed with spatial autocorrelation controlled. Significant correlations were only found for exposure to sunlight and rainfall and it was similar in both genders. The annual average of the former was found to be negatively correlated with ALS, while the latter was positively correlated with ALS incidence. While accepting that ALS is most probably multifactorial, it was concluded that sunlight deprivation and/or rainfall are associated to some degree with ALS incidence in Taiwan.
Genome-Scale Screening of Drug-Target Associations Relevant to Ki Using a Chemogenomics Approach
Cao, Dong-Sheng; Liang, Yi-Zeng; Deng, Zhe; Hu, Qian-Nan; He, Min; Xu, Qing-Song; Zhou, Guang-Hua; Zhang, Liu-Xia; Deng, Zi-xin; Liu, Shao
2013-01-01
The identification of interactions between drugs and target proteins plays a key role in genomic drug discovery. In the present study, the quantitative binding affinities of drug-target pairs are differentiated as a measurement to define whether a drug interacts with a protein or not, and then a chemogenomics framework using an unbiased set of general integrated features and random forest (RF) is employed to construct a predictive model which can accurately classify drug-target pairs. The predictability of the model is further investigated and validated by several independent validation sets. The built model is used to predict drug-target associations, some of which were confirmed by comparing experimental data from public biological resources. A drug-target interaction network with high confidence drug-target pairs was also reconstructed. This network provides further insight for the action of drugs and targets. Finally, a web-based server called PreDPI-Ki was developed to predict drug-target interactions for drug discovery. In addition to providing a high-confidence list of drug-target associations for subsequent experimental investigation guidance, these results also contribute to the understanding of drug-target interactions. We can also see that quantitative information of drug-target associations could greatly promote the development of more accurate models. The PreDPI-Ki server is freely available via: http://sdd.whu.edu.cn/dpiki. PMID:23577055
Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowshanfarzad, Pejman; Sabet, Mahsheed; O'Connor, Daryl J.
2012-02-15
Purpose: Electronic portal imaging devices (EPIDs) have been studied and used for pretreatment and in-vivo dosimetry applications for many years. The application of EPIDs for dosimetry in arc treatments requires accurate characterization of the mechanical sag of the EPID and gantry during rotation. Several studies have investigated the effects of gravity on the sag of these systems but each have limitations. In this study, an easy experiment setup and accurate algorithm have been introduced to characterize and correct for the effect of EPID and gantry sag during arc delivery. Methods: Three metallic ball bearings were used as markers in themore » beam: two of them fixed to the gantry head and the third positioned at the isocenter. EPID images were acquired during a 360 deg. gantry rotation in cine imaging mode. The markers were tracked in EPID images and a robust in-house developed MATLAB code was used to analyse the images and find the EPID sag in three directions as well as the EPID + gantry sag by comparison to the reference gantry zero image. The algorithm results were then tested against independent methods. The method was applied to compare the effect in clockwise and counter clockwise gantry rotations and different source-to-detector distances (SDDs). The results were monitored for one linear accelerator over a course of 15 months and six other linear-accelerators from two treatment centers were also investigated using this method. The generalized shift patterns were derived from the data and used in an image registration algorithm to correct for the effect of the mechanical sag in the system. The Gamma evaluation (3%, 3 mm) technique was used to investigate the improvement in alignment of cine EPID images of a fixed field, by comparing both individual images and the sum of images in a series with the reference gantry zero image. Results: The mechanical sag during gantry rotation was dependent on the gantry angle and was larger in the in-plane direction, although the patterns were not identical for various linear-accelerators. The reproducibility of measurements was within 0.2 mm over a period of 15 months. The direction of gantry rotation and SDD did not affect the results by more than 0.3 mm. Results of independent tests agreed with the algorithm within the accuracy of the measurement tools. When comparing summed images, the percentage of points with Gamma index <1 increased from 85.4% to 94.1% after correcting for the EPID sag, and to 99.3% after correction for gantry + EPID sag. Conclusions: The measurement method and algorithms introduced in this study use cine-images, are highly accurate, simple, fast, and reproducible. It tests all gantry angles and provides a suitable automatic analysis and correction tool to improve EPID dosimetry and perform comprehensive linac QA for arc treatments.« less
PDSM characterization for fabrication of free-space OXC optical components
NASA Astrophysics Data System (ADS)
Argueta, Victor; Fitzpatrick, Brianna
2017-11-01
In 2007 Dr Khine et al published a paper where they presented a technique using thermoplastics and PDMS to create microfluidic patterns1. Their technique involves printing a pattern in a polystyrene sheet using a laser printer. Once the pattern is transfer the polystyrene sheets they are heated to reduce their size. By printing the same pattern of the plastic sheets before heating, it is possible to control the height up to 80 μm and the width as thin as 65 μm1, 2. This technique is attractive to be used in optical fabrication due to its versatility, low cost and fast prototyping. However, in order to fabricate optical systems, we will need to control the refractive index of PDMS to allow design of basic optical components like waveguides, beam splitter, or diffuse reflectors; or more complex structures like interferometers, optical microfluidic lab-on-chip, micro-lens arrays. Several techniques exist to control the refractive index for PDMS either by controlling the curing temperature, the ratio between the base and curing agent, or by curing using UV light3-5. In this paper, we present the changes on refractive index by changing the curing temperature for different base/reaction agent ratios. We then apply these results to fabricate an optical component for a free-space optical cross-connect (OXC). Optical cross-connects are an important network element for constructing the next generation of optical networks, where provisioning (reconfiguration), scalability, and fast restoration will be needed6-8. The main attraction of all-optical switching is that it enables routing of optical data signals without the need for conversion to electrical signals, and therefore, is independent of data rate and data protocols. We have proposed previously9, 11 a new approach for an OXC. Our architecture is a free-space 3-D while still using digital MEMS. Our system is based on the optical White cell12, which consists of three spherical mirrors among which light can circulate. In Section II, we will briefly mention the basic characteristics of the binary White cell OXC configuration. Section III we will introduce the changes induced on curing PDMS, our SDD design and its fabrication for two different beam displacements. Finally, in Section IV, we will present the summary and conclusions of our work.
Brodusch, Nicolas; Gauvin, Raynald
2017-09-01
Electron channelling is known to affect the x-ray production when an accelerated electron beam is applied to a crystalline material and is highly dependent on the local crystal orientation. This effect, unless very long counting time are used, is barely noticeable on x-ray energy spectra recorded with conventional silicon drift detectors (SDD) located at a small elevation angle. However, the very high count rates provided by the new commercially available annular SDDs permit now to observe this effect routinely and may, in some circumstances, hide the true elemental x-ray variations due to the local true specimen composition. To circumvent this issue, the recently developed f-ratio method was applied to display qualitatively the true net intensity x-ray variations in a thin specimen of a Ti-6Al-4V alloy in a scanning electron microscope in transmission mode. The diffraction contrast observed in the x-ray images was successfully cancelled through the use of f-ratios and the true composition variations at the grain boundaries could be observed in relation to the dislocation alignment prior to the β-phase nucleation. The qualitative effectiveness in removing channelling effects demonstrated in this work makes the f-ratio, in its quantitative form, a possible alternative to the ZAF method in channelling conditions. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.
Is scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) quantitative?
Newbury, Dale E; Ritchie, Nicholas W M
2013-01-01
Scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) is a widely applied elemental microanalysis method capable of identifying and quantifying all elements in the periodic table except H, He, and Li. By following the "k-ratio" (unknown/standard) measurement protocol development for electron-excited wavelength dispersive spectrometry (WDS), SEM/EDS can achieve accuracy and precision equivalent to WDS and at substantially lower electron dose, even when severe X-ray peak overlaps occur, provided sufficient counts are recorded. Achieving this level of performance is now much more practical with the advent of the high-throughput silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS). However, three measurement issues continue to diminish the impact of SEM/EDS: (1) In the qualitative analysis (i.e., element identification) that must precede quantitative analysis, at least some current and many legacy software systems are vulnerable to occasional misidentification of major constituent peaks, with the frequency of misidentifications rising significantly for minor and trace constituents. (2) The use of standardless analysis, which is subject to much broader systematic errors, leads to quantitative results that, while useful, do not have sufficient accuracy to solve critical problems, e.g. determining the formula of a compound. (3) EDS spectrometers have such a large volume of acceptance that apparently credible spectra can be obtained from specimens with complex topography that introduce uncontrolled geometric factors that modify X-ray generation and propagation, resulting in very large systematic errors, often a factor of ten or more. © Wiley Periodicals, Inc.
Atzema, Clare L; Austin, Peter C; Wu, Libo; Brzozowski, Michael; Feldman, Michael J; McDonnell, Michael; Mazurik, Laurie
2013-01-01
Emergency department discharge instructions are variably understood by patients, and in the setting of emergency department crowding, innovations are needed to counteract shortened interaction times with the physician. We evaluated the effect of viewing an online video of diagnosis-specific discharge instructions on patient comprehension and recall of instructions. In this prospective, single-center, randomized controlled trial conducted between November 2011 and January 2012, we randomized emergency department patients who were discharged with one of 38 diagnoses to either view (after they left the emergency department) a vetted online video of diagnosis-specific discharge instructions, or to usual care. Patients were subsequently contacted by telephone and asked three standardized questions about their discharge instructions; one point was awarded for each correct answer. Using an intention-to-treat analysis, differences between groups were assessed using univariate testing, and with logistic regression that accounted for clustering on managing physician. A secondary outcome measure was patient satisfaction with the videos, on a 10-point scale. Among 133 patients enrolled, mean age was 46.1 (s.d.D. 21.5) and 55% were female. Patients in the video group had 19% higher mean scores (2.5, s.d. 0.7) than patients in the control group (2.1, s.d. 0.8) (p=0.002). After adjustment for patient age, sex, first language, triage acuity score, and clustering, the odds of achieving a fully correct score (3 out of 3) were 3.5 (95% CI, 1.7 to 7.2) times higher in the video group, compared to the control group. Among those who viewed the videos, median rating of the videos was 10 (IQR 8 to 10). In this single-center trial, patients who viewed an online video of their discharge instructions scored higher on their understanding of key concepts around their diagnosis and subsequent care. Those who viewed the videos found them to be a helpful addition to standard care. ClinicalTrials.gov NCT01361932 http://clinicaltrials.gov/ct2/show/NCT01361932?term=nct01361932&rank=1.
Coupling of snow and permafrost processes using the Basic Modeling Interface (BMI)
NASA Astrophysics Data System (ADS)
Wang, K.; Overeem, I.; Jafarov, E. E.; Piper, M.; Stewart, S.; Clow, G. D.; Schaefer, K. M.
2017-12-01
We developed a permafrost modeling tool based by implementing the Kudryavtsev empirical permafrost active layer depth model (the so-called "Ku" component). The model is specifically set up to have a basic model interface (BMI), which enhances the potential coupling to other earth surface processes model components. This model is accessible through the Web Modeling Tool in Community Surface Dynamics Modeling System (CSDMS). The Kudryavtsev model has been applied for entire Alaska to model permafrost distribution at high spatial resolution and model predictions have been verified by Circumpolar Active Layer Monitoring (CALM) in-situ observations. The Ku component uses monthly meteorological forcing, including air temperature, snow depth, and snow density, and predicts active layer thickness (ALT) and temperature on the top of permafrost (TTOP), which are important factors in snow-hydrological processes. BMI provides an easy approach to couple the models with each other. Here, we provide a case of coupling the Ku component to snow process components, including the Snow-Degree-Day (SDD) method and Snow-Energy-Balance (SEB) method, which are existing components in the hydrological model TOPOFLOW. The work flow is (1) get variables from meteorology component, set the values to snow process component, and advance the snow process component, (2) get variables from meteorology and snow component, provide these to the Ku component and advance, (3) get variables from snow process component, set the values to meteorology component, and advance the meteorology component. The next phase is to couple the permafrost component with fully BMI-compliant TOPOFLOW hydrological model, which could provide a useful tool to investigate the permafrost hydrological effect.
Prevalence & susceptibility to fluconazole of Candida species causing vulvovaginitis.
Mohanty, Srujana; Xess, Immaculata; Hasan, Fahmi; Kapil, Arti; Mittal, Suneeta; Tolosa, Jorge E
2007-09-01
Vulvovaginal candidiasis is an important cause of morbidity in women of reproductive age. This study was carried out to determine the species prevalence and susceptibility pattern to fluconazole of yeasts isolated from the vagina of symptomatic women. This prospective study was conducted in a rural primary health care center of north India from May 2003 to April 2004 and included 601 married, sexually active women (18-49 yr) with the self reported symptoms of vaginal discharge and/or genital itching and/or genital burning. Specific aetiology of the genitourinary symptoms including candidal infection were determined. Specimens from the lateral wall of vagina were subjected to direct wet mount microscopy and fungal culture on Sabouraud's dextrose agar. Susceptibility testing to fluconazole was carried out using broth microdilution method. Yeasts were isolated in 111 (18.5%) women and these consisted of Candida glabrata (56, 50.4%), C. albicans (39, 35.1%), C. tropicalis (12, 10.8%), C. krusei (3, 2.7%) and C. parapsilosis (1, 0.9%). Susceptibility testing carried out on 30 representative isolates (15 C. glabrata, 10 C. albicans, 4 C. tropicalis and 1 C. parapsilosis) revealed that 21 isolates (70%) were susceptible (MIC, < or = 8 microg/ml) to fluconazole while 9 (30%) were susceptible-dose dependent (S-DD, MIC 16-32 microg/ml). Our findings suggest a low prevalence of fluconazole resistance in vaginal candida isolates in our population. However, a high prevalence of non-albicans candida species and increased dose-dependent resistance in these isolates necessitates vigilance since this may warrant a change in the optimal therapy of non-albicans candida vaginitis.
Zore, Gajanan B; Thakre, Archana D; Rathod, V; Karuppayil, S Mohan
2011-07-01
Fluconazole (FLC) susceptibility of isolates of Candida spp., (n = 42) and efficacy as well as mechanism of anti-Candida activity of three constituents of geranium oil is evaluated in this study. No fluconazole resistance was observed among the clinical isolates tested, however 22% were susceptible-dose-dependent (S-DD) [minimal inhibitory concentration (MIC) ≥ 16 μg ml(-1)] and a standard strain of C. albicans ATCC 10231 was resistant (≥ 64 μg ml(-1)). Geraniol and geranyl acetate were equally effective, fungicidal at 0.064% v/v concentrations i.e. MICs (561 μg ml(-1) and 584 μg ml(-1) respectively) and killed 99.9% inoculum within 15 and 30 min of exposures respectively. Citronellol was least effective and fungistatic. C. albicans dimorphism (Y → H) was highly sensitive to geranium oil constituents tested (IC50 approximately 0.008% v/v). Geraniol, geranyl acetate and citronellol brought down MICs of FLC by 16-, 32- and 64-fold respectively in a FLC-resistant strain. Citronellol and geraniol arrested cells in G1 phase while geranyl acetate in G2-M phase of cell cycle at MIC(50). In vitro cytotoxicity study revealed that geraniol, geranyl acetate and citronellol were non-toxic to HeLa cells at MICs of the C. albicans growth. Our results indicate that two of the three geranium oil constituents tested exhibit excellent anti-Candida activity and significant synergistic activity with fluconazole. © 2010 Blackwell Verlag GmbH.
Characterisation of an accelerator-based neutron source for BNCT versus beam energy
NASA Astrophysics Data System (ADS)
Agosteo, S.; Curzio, G.; d'Errico, F.; Nath, R.; Tinti, R.
2002-01-01
Neutron capture in 10B produces energetic alpha particles that have a high linear energy transfer in tissue. This results in higher cell killing and a higher relative biological effectiveness compared to photons. Using suitably designed boron compounds which preferentially localize in cancerous cells instead of healthy tissues, boron neutron capture therapy (BNCT) has the potential of providing a higher tumor cure rate within minimal toxicity to normal tissues. This clinical approach requires a thermal neutron source, generally a nuclear reactor, with a fluence rate sufficient to deliver tumorcidal doses within a reasonable treatment time (minutes). Thermal neutrons do not penetrate deeply in tissue, therefore BNCT is limited to lesions which are either superficial or otherwise accessible. In this work, we investigate the feasibility of an accelerator-based thermal neutron source for the BNCT of skin melanomas. The source was designed via MCNP Monte Carlo simulations of the thermalization of a fast neutron beam, generated by 7 MeV deuterons impinging on a thick target of beryllium. The neutron field was characterized at several deuteron energies (3.0-6.5 MeV) in an experimental structure installed at the Van De Graaff accelerator of the Laboratori Nazionali di Legnaro, in Italy. Thermal and epithermal neutron fluences were measured with activation techniques and fast neutron spectra were determined with superheated drop detectors (SDD). These neutron spectrometry and dosimetry studies indicated that the fast neutron dose is unacceptably high in the current design. Modifications to the current design to overcome this problem are presented.
Image quality specification and maintenance for airborne SAR
NASA Astrophysics Data System (ADS)
Clinard, Mark S.
2004-08-01
Specification, verification, and maintenance of image quality over the lifecycle of an operational airborne SAR begin with the specification for the system itself. Verification of image quality-oriented specification compliance can be enhanced by including a specification requirement that a vendor provide appropriate imagery at the various phases of the system life cycle. The nature and content of the imagery appropriate for each stage of the process depends on the nature of the test, the economics of collection, and the availability of techniques to extract the desired information from the data. At the earliest lifecycle stages, Concept and Technology Development (CTD) and System Development and Demonstration (SDD), the test set could include simulated imagery to demonstrate the mathematical and engineering concepts being implemented thus allowing demonstration of compliance, in part, through simulation. For Initial Operational Test and Evaluation (IOT&E), imagery collected from precisely instrumented test ranges and targets of opportunity consisting of a priori or a posteriori ground-truthed cultural and natural features are of value to the analysis of product quality compliance. Regular monitoring of image quality is possible using operational imagery and automated metrics; more precise measurements can be performed with imagery of instrumented scenes, when available. A survey of image quality measurement techniques is presented along with a discussion of the challenges of managing an airborne SAR program with the scarce resources of time, money, and ground-truthed data. Recommendations are provided that should allow an improvement in the product quality specification and maintenance process with a minimal increase in resource demands on the customer, the vendor, the operational personnel, and the asset itself.
a Method of Time-Series Change Detection Using Full Polsar Images from Different Sensors
NASA Astrophysics Data System (ADS)
Liu, W.; Yang, J.; Zhao, J.; Shi, H.; Yang, L.
2018-04-01
Most of the existing change detection methods using full polarimetric synthetic aperture radar (PolSAR) are limited to detecting change between two points in time. In this paper, a novel method was proposed to detect the change based on time-series data from different sensors. Firstly, the overall difference image of a time-series PolSAR was calculated by ominous statistic test. Secondly, difference images between any two images in different times ware acquired by Rj statistic test. Generalized Gaussian mixture model (GGMM) was used to obtain time-series change detection maps in the last step for the proposed method. To verify the effectiveness of the proposed method, we carried out the experiment of change detection by using the time-series PolSAR images acquired by Radarsat-2 and Gaofen-3 over the city of Wuhan, in China. Results show that the proposed method can detect the time-series change from different sensors.
Dangerous gas detection based on infrared video
NASA Astrophysics Data System (ADS)
Ding, Kang; Hong, Hanyu; Huang, Likun
2018-03-01
As the gas leak infrared imaging detection technology has significant advantages of high efficiency and remote imaging detection, in order to enhance the detail perception of observers and equivalently improve the detection limit, we propose a new type of gas leak infrared image detection method, which combines background difference methods and multi-frame interval difference method. Compared to the traditional frame methods, the multi-frame interval difference method we proposed can extract a more complete target image. By fusing the background difference image and the multi-frame interval difference image, we can accumulate the information of infrared target image of the gas leak in many aspect. The experiment demonstrate that the completeness of the gas leakage trace information is enhanced significantly, and the real-time detection effect can be achieved.
Amponsah, Amma; Nayak, Balunkeswar
2018-04-01
Recent studies have shown the need to improve soy allergen extraction using different extraction conditions to ensure more accurate results in allergen detection. This study investigated some of these extraction conditions to confirm that these methods, especially ultrasound-assisted extraction (UAE) and the use of Laemmli buffer instead of the conventional extraction with phosphate-buffered saline (PBS), could be helpful in improving the extraction step in allergen detection. Higher total soluble protein was obtained in all samples extracted with Laemmli buffer alone and in combination with ultrasound. For immunochemical detection of soy proteins by enzyme-linked immunosorbent assay (ELISA), comparable detection was observed in extracts from all extraction conditions in all commercial samples with the exception of table cracker and veggie burger, where significantly higher detection was seen in extracts from Laemmli buffer only. For the dry mix and cookie samples, the degree of soy protein detection with ELISA varied among the different extraction conditions, but overall, extraction with only Laemmli buffer showed higher detection. Laemmli buffer with conventional extraction and UAE may be better alternatives or additional extraction methods in soy allergen detection. Different food matrices performed differently (whether it was for the recovery of total proteins or detection by ELISA) under different extraction conditions. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Chorny, Joseph A; Frye, Teresa C; Fisher, Beth L; Remmers, Carol L
2018-03-23
The primary high-risk human papillomavirus (hrHPV) assays in the United States are the cobas (Roche) and the Aptima (Hologic). The cobas assay detects hrHPV by DNA analysis while the Aptima detects messenger RNA (mRNA) oncogenic transcripts. As the Aptima assay identifies oncogenic expression, it should have a lower rate of hrHPV and genotype detection. The Kaiser Permanente Regional Reference Laboratory in Denver, Colorado changed its hrHPV assay from the cobas to the Aptima assay. The rates of hrHPV detection and genotyping were compared over successive six-month periods. The overall hrHPV detection rates by the two platforms were similar (9.5% versus 9.1%) and not statistically different. For genotyping, the HPV 16 rate by the cobas was 1.6% and by the Aptima it was 1.1%. These differences were statistically different with the Aptima detecting nearly one-third less HPV 16 infections. With the HPV 18 and HPV 18/45, there was a slightly higher detection rate of HPV 18/45 by the Aptima platform (0.5% versus 0.9%) and this was statistically significant. While HPV 16 represents a low percentage of hrHPV infections, it was detected significantly less by the Aptima assay compared to the cobas assay. This has been previously reported, although not highlighted. Given the test methodologies, one would expect the Aptima to detect less HPV 16. This difference appears to be mainly due to a significantly increased number of non-oncogenic HPV 16 infections detected by the cobas test as there were no differences in HPV 16 detection rates in the high-grade squamous intraepithelial lesions indicating that the two tests have similar sensitivities for oncogenic HPV 16. © 2018 Wiley Periodicals, Inc.
Investigations of internal noise levels for different target sizes, contrasts, and noise structures
NASA Astrophysics Data System (ADS)
Han, Minah; Choi, Shinkook; Baek, Jongduk
2014-03-01
To describe internal noise levels for different target sizes, contrasts, and noise structures, Gaussian targets with four different sizes (i.e., standard deviation of 2,4,6 and 8) and three different noise structures(i.e., white, low-pass, and highpass) were generated. The generated noise images were scaled to have standard deviation of 0.15. For each noise type, target contrasts were adjusted to have the same detectability based on NPW, and the detectability of CHO was calculated accordingly. For human observer study, 3 trained observers performed 2AFC detection tasks, and correction rate, Pc, was calculated for each task. By adding proper internal noise level to numerical observer (i.e., NPW and CHO), detectability of human observer was matched with that of numerical observers. Even though target contrasts were adjusted to have the same detectability of NPW observer, detectability of human observer decreases as the target size increases. The internal noise level varies for different target sizes, contrasts, and noise structures, demonstrating different internal noise levels should be considered in numerical observer to predict the detection performance of human observer.
P.S. Homann; B.T. Bormann; J.R. Boyle; R.L. Darbyshire; R. Bigley
2008-01-01
Detecting changes in forest soil C and N is vital to the study of global budgets and long-term ecosystem productivity. Identifying differences among land-use practices may guide future management. Our objective was to determine the relation of minimum detectable changes (MDCs) and minimum detectable differences between treatments (MDDs) to soil C and N variability at...
Yang, Hua-Qing; Fu, Hong-Quan; Su, Ben-Fang; Xiang, Bo; Xu, Qian-Qian; Hu, Chang-Wei
2015-11-25
The catalytic mechanism of 2NO + 2CO → N2 + 2CO2 on Rh4 cluster has been systematically investigated on the ground and first excited states at the B3LYP/6-311+G(2d),SDD level. For the overall reaction of 2NO + 2CO → N2 + 2CO2, the main reaction pathways take place on the facet site rather than the edge site of the Rh4 cluster. The turnover frequency (TOF) determining transition states are characteristic of the second N-O bond cleavage with rate constant k4 = 1.403 × 10(11) exp (-181 203/RT) and the N-N bond formation for the intermediate N2O formation with rate constant k2 = 3.762 × 10(12) exp (-207 817/RT). The TOF-determining intermediates of (3)N(b)Rh4NO and (3)N(b)Rh4O(b)(NO) are associated with the nitrogen-atom molecular complex, which is in agreement with the experimental observation of surface nitrogen. On the facet site of Rh4 cluster, the formation of CO2 stems solely from the recombination of CO and O atom, while N2 originates partly from the recombination of two N atoms and partly from the decomposition of N2O. For the N-O bond cleavage or the synchronous N-O bond cleavage and C-O bond formation, the neutral Rh4 cluster exhibits better catalytic performance than the cationic Rh4(+) cluster. Alternatively, for N-N bond formation, the cationic Rh4(+) cluster possesses better catalytic performance than the neutral Rh4 cluster.
Bowman, David N; Bondarev, Alexey; Mukherjee, Sriparna; Jakubikova, Elena
2015-09-08
Fe(II) polypyridines are an important class of pseudo-octahedral metal complexes known for their potential applications in molecular electronic switches, data storage and display devices, sensors, and dye-sensitized solar cells. Fe(II) polypyridines have a d(6) electronic configuration and pseudo-octahedral geometry and can therefore possess either a high-spin (quintet) or a low-spin (singlet) ground state. In this study, we investigate a series of complexes based on [Fe(tpy)2](2+) (tpy = 2,2';6',2″-terpyridine) and [Fe(dcpp)2](2+) (dcpp = 2,6-bis(2-carboxypyridyl)pyridine). The ligand field strength in these complexes is systematically tuned by replacing the central pyridine with five-membered (N-heterocyclic carbene, pyrrole, furan) or six-membered (aryl, thiazine-1,1-dioxide, 4-pyrone) moieties. To determine the impact of ligand substitutions on the relative energies of metal-centered states, the singlet, triplet, and quintet states of the Fe(II) complexes were optimized in water (PCM) using density functional theory at the B3LYP+D2 level with 6-311G* (nonmetals) and SDD (Fe) basis sets. It was found that the dcpp ligand scaffold allows for a more ideal octahedral coordination environment in comparison to the tpy ligand scaffold. The presence of six-membered central rings also allows for a more ideally octahedral coordination environment relative to five-membered central rings, regardless of the ligand scaffold. We find that the ligand field strength in the Fe(II) polypyridines can be tuned by altering the donor atom identity, with C donor atoms providing the strongest ligand field.
Nittala, Muneeswar G; Song, Yeunjoo E; Sardell, Rebecca; Adams, Larry D; Pan, Samuel; Velaga, Swetha B; Horst, Violet; Dana, Debra; Caywood, Laura; Laux, Renee; Fuzzell, Denise; Fuzzell, Sarada; Scott, William K; Cooke Bailey, Jessica N; Igo, Robert P; Haines, Jonathan; Pericak-Vance, Margaret A; Sadda, SriniVas R; Stambolian, Dwight
2018-05-09
To describe spectral domain optical coherence tomography (SD-OCT) findings in an Amish cohort to assess SD-OCT markers for early age-related macular degeneration (AMD). The authors performed a family-based prospective cohort study of 1,146 elderly Amish subjects (age range 50-99 years) (2,292 eyes) who had a family history of at least 1 individual with AMD. All subjects underwent complete ophthalmic examinations, SD-OCT using both Cirrus and Spectralis (20 × 20° scan area) instruments, fundus autofluorescence, infrared imaging, and color fundus photography. Spectral domain optical coherence tomography characteristics were analyzed in subjects with AMD (with and without subretinal drusenoid deposits [SDDs]) and normal healthy cohorts. Participants' mean age was 65.2 years (SD ± 11). Color fundus photographic findings in 596 (53%) subjects (1,009 eyes) were consistent with AMD; the remaining 478 (43%) subjects showed no signs of AMD. The choroid was significantly thinner on OCT (242 ± 76 µm, P < 0.001) in those with AMD compared with those without (263 ± 63 µm). Subretinal drusenoid deposits were found in 143 eyes (7%); 11 of the 143 eyes (8%) had no other manifestations of AMD. Drusen volume (P < 0.001) and area of geographic atrophy (P < 0.001) were significantly greater, and choroid was significantly (P < 0.001) thinner in subjects with SDDs versus those without SDDs. The authors describe spectral domain optical coherence tomography characteristics in an elderly Amish population with and without AMD, including the frequency of SDD. Although relatively uncommon in this population, the authors confirmed that SDDs can be found in the absence of other features of AMD and that eyes with SDDs have thinner choroids.
Development of a versatile XRF scanner for the elemental imaging of paintworks
NASA Astrophysics Data System (ADS)
Ravaud, E.; Pichon, L.; Laval, E.; Gonzalez, V.; Eveno, M.; Calligaro, T.
2016-01-01
Scanning XRF is a powerful elemental imaging technique introduced at the synchrotron that has recently been transposed to laboratory. The growing interest in this technique stems from its ability to collect images reflecting pigment distribution within large areas on artworks by means of their elemental signature. In that sense, scanning XRF appears highly complementary to standard imaging techniques (Visible, UV, IR photography and X-ray radiography). The versatile XRF scanner presented here has been designed and built at the C2RMF in response to specific constraints: transportability, cost-effectiveness and ability to scan large areas within a single working day. The instrument is based on a standard X-ray generator with sub-millimetre collimated beam and a SDD-based spectrometer to collected X-ray spectra. The instrument head is scanned in front of the painting by means of motorised movements to cover an area up to 300 × 300 mm2 with a resolution of 0.5 mm (600 × 600 pixels). The 15-kg head is mounted on a stable photo stand for rapid positioning on paintworks and maintains a free side-access for safety; it can also be attached to a lighter tripod for field measurements. Alignment is achieved with a laser pointer and a micro-camera. With a scanning speed of 5 mm/s and 0.1 s/point, elemental maps are collected in 10 h, i.e. a working day. The X-ray spectra of all pixels are rapidly processed using an open source program to derive elemental maps. To illustrate the capabilities of this instrument, this contribution presents the results obtained on the Belle Ferronnière painted by Leonardo da Vinci (1452-1519) and conserved in the Musée du Louvre, prior to its restoration at the C2RMF.
NEW OBSERVATIONS OF THE SOLAR 0.5–5 KEV SOFT X-RAY SPECTRUM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caspi, Amir; Woods, Thomas N.; Warren, Harry P.
2015-03-20
The solar corona is orders of magnitude hotter than the underlying photosphere, but how the corona attains such high temperatures is still not understood. Soft X-ray (SXR) emission provides important diagnostics for thermal processes in the high-temperature corona, and is also an important driver of ionospheric dynamics at Earth. There is a crucial observational gap between ∼0.2 and ∼4 keV, outside the ranges of existing spectrometers. We present observations from a new SXR spectrometer, the Amptek X123-SDD, which measured the spatially integrated solar spectral irradiance from ∼0.5 to ∼5 keV, with ∼0.15 keV FWHM resolution, during sounding rocket flights onmore » 2012 June 23 and 2013 October 21. These measurements show that the highly variable SXR emission is orders of magnitude greater than that during the deep minimum of 2009, even with only weak activity. The observed spectra show significant high-temperature (5–10 MK) emission and are well fit by simple power-law temperature distributions with indices of ∼6, close to the predictions of nanoflare models of coronal heating. Observations during the more active 2013 flight indicate an enrichment of low first-ionization potential elements of only ∼1.6, below the usually observed value of ∼4, suggesting that abundance variations may be related to coronal heating processes. The XUV Photometer System Level 4 data product, a spectral irradiance model derived from integrated broadband measurements, significantly overestimates the spectra from both flights, suggesting a need for revision of its non-flare reference spectra, with important implications for studies of Earth ionospheric dynamics driven by solar SXRs.« less
Effect of Age and Glaucoma on the Detection of Darks and Lights
Zhao, Linxi; Sendek, Caroline; Davoodnia, Vandad; Lashgari, Reza; Dul, Mitchell W.; Zaidi, Qasim; Alonso, Jose-Manuel
2015-01-01
Purpose We have shown previously that normal observers detect dark targets faster and more accurately than light targets, when presented in noisy backgrounds. We investigated how these differences in detection time and accuracy are affected by age and ganglion cell pathology associated with glaucoma. Methods We asked 21 glaucoma patients, 21 age-similar controls, and 5 young control observers to report as fast as possible the number of 1 to 3 light or dark targets. The targets were positioned at random in a binary noise background, within the central 30° of the visual field. Results We replicate previous findings that darks are detected faster and more accurately than lights. We extend these findings by demonstrating that differences in detection of darks and lights are found reliably across different ages and in observers with glaucoma. We show that differences in detection time increase at a rate of approximately 55 msec/dB at early stages of glaucoma and then remain constant at later stages at approximately 800 msec. In normal subjects, differences in detection time increase with age at a rate of approximately 8 msec/y. We also demonstrate that the accuracy to detect lights and darks is significantly correlated with the severity of glaucoma and that the mean detection time is significantly longer for subjects with glaucoma than age-similar controls. Conclusions We conclude that differences in detection of darks and lights can be demonstrated over a wide range of ages, and asymmetries in dark/light detection increase with age and early stages of glaucoma. PMID:26513506
Effect of Age and Glaucoma on the Detection of Darks and Lights.
Zhao, Linxi; Sendek, Caroline; Davoodnia, Vandad; Lashgari, Reza; Dul, Mitchell W; Zaidi, Qasim; Alonso, Jose-Manuel
2015-10-01
We have shown previously that normal observers detect dark targets faster and more accurately than light targets, when presented in noisy backgrounds. We investigated how these differences in detection time and accuracy are affected by age and ganglion cell pathology associated with glaucoma. We asked 21 glaucoma patients, 21 age-similar controls, and 5 young control observers to report as fast as possible the number of 1 to 3 light or dark targets. The targets were positioned at random in a binary noise background, within the central 30° of the visual field. We replicate previous findings that darks are detected faster and more accurately than lights. We extend these findings by demonstrating that differences in detection of darks and lights are found reliably across different ages and in observers with glaucoma. We show that differences in detection time increase at a rate of approximately 55 msec/dB at early stages of glaucoma and then remain constant at later stages at approximately 800 msec. In normal subjects, differences in detection time increase with age at a rate of approximately 8 msec/y. We also demonstrate that the accuracy to detect lights and darks is significantly correlated with the severity of glaucoma and that the mean detection time is significantly longer for subjects with glaucoma than age-similar controls. We conclude that differences in detection of darks and lights can be demonstrated over a wide range of ages, and asymmetries in dark/light detection increase with age and early stages of glaucoma.
On precise phase difference measurement approach using border stability of detection resolution.
Bai, Lina; Su, Xin; Zhou, Wei; Ou, Xiaojuan
2015-01-01
For the precise phase difference measurement, this paper develops an improved dual phase coincidence detection method. The measurement resolution of the digital phase coincidence detection circuits is always limited, for example, only at the nanosecond level. This paper reveals a new way to improve the phase difference measurement precision by using the border stability of the circuit detection fuzzy areas. When a common oscillator signal is used to detect the phase coincidence with the two comparison signals, there will be two detection fuzzy areas for the reason of finite detection resolution surrounding the strict phase coincidence. Border stability of fuzzy areas and the fluctuation difference of the two fuzzy areas can be even finer than the picoseconds level. It is shown that the system resolution obtained only depends on the stability of the circuit measurement resolution which is much better than the measurement device resolution itself.
The role of illicit, licit, and designer drugs in the traffic in Hungary.
Institóris, László; Hidvégi, Előd; Dobos, Adrienn; Sija, Éva; Kereszty, Éva M; Tajti, László Balázs; Somogyi, Gábor Pál; Varga, Tibor
2017-06-01
The aim of this study was to investigate the prevalence and pattern of psychoactive substances among suspected DUID (Driving Under the Influence of Drugs) drivers in Hungary in 2014 and 2015. Blood and/or urine samples of 1252 suspected drivers (600 in 2014 and 652 in 2015) were analyzed for classical illicit and licit drugs, stimulant designer drugs (SDDs), and for synthetic cannabinoids, with 78.3% and 79.6% positive cases for at least one substance in 2014, and 2015, respectively. Impairment was proven in 39.2% (2014) and 35.7% (2015) of all drivers tested, based on the legal criteria of Hungary. Classical illicit drugs were found to be present in blood or urine of 89-61%, drivers tested. Drivers also tested positive for legal medications in 20-22%, SDDs in 21-28%, and synthetic cannabinoids in 15-19% of all cases. This indicates a drop in prevalence for classical illicit drugs and a slight but statistically non-significant increase for the other three substance groups. The distribution of drug types in each category were: [1] classical illicit drugs: cannabis (432), amphetamine (321), and cocaine (79); [2] medicines: alprazolam (94) and clonazepam (36); [3] SDDs: pentedrone (137) and α-PVP (33); [4] synthetic cannabinoids: AB-CHMINACA (46) and MDMB-CHMICA (30). The average age of illicit drug and SDD users was 30 years, while legal medications users were 36 years old on average, and the mean age of synthetic cannabinoid users was 26.5 years. The presence of both alcohol and at least one drug in samples was found in about 10% of the cases, both years. The ratio of multi-drug use was 33.0% in 2014 and 41.3% in 2015. Compared to former years the number of drivers who tested positive for drugs doubled in Hungary, but it is still low compared to alcohol positive cases. The relatively low detected rate of DUID can be explained by (1) combined alcohol consumption masking drug symptoms, (2) the absence of road-side tests for illicit and designer drugs and, (3) police officers not adequately trained to recognize milder symptoms of impairment. Targeted education of police officers, prompt medical examination and the use of a symptom-focused on-site survey, could improve the efficacy of DUID investigations. Our findings are not comparable with drug consumption habits of the general driving population. The last roadside survey (DRUID EU-6 Project) was performed in Hungary in 2008-2009, prior to the mass spreading of designer drugs. As their appearance has drastically changed the pattern of drug consumption of the population, a new roadside survey, targeting general drivers, would be necessary. Copyright © 2017 Elsevier B.V. All rights reserved.
Strawberry Maturity Neural Network Detectng System Based on Genetic Algorithm
NASA Astrophysics Data System (ADS)
Xu, Liming
The quick and non-detective detection of agriculture product is one of the measures to increase the precision and productivity of harvesting and grading. Having analyzed H frequency of different maturities in different light intensities, the results show that H frequency for the same maturity has little influence in different light intensities; Under the same light intensity, three strawberry maturities are changing in order. After having confirmed the H frequency section to distinguish the different strawberry maturity, the triplelayer feed-forward neural network system to detect strawberry maturity was designed by using genetic algorithm. The test results show that the detecting precision ratio is 91.7%, it takes 160ms to distinguish one strawberry. Therefore, the online non-detective detecting the strawberry maturity could be realized.
A Comparative Evaluation of Unsupervised Anomaly Detection Algorithms for Multivariate Data.
Goldstein, Markus; Uchida, Seiichi
2016-01-01
Anomaly detection is the process of identifying unexpected items or events in datasets, which differ from the norm. In contrast to standard classification tasks, anomaly detection is often applied on unlabeled data, taking only the internal structure of the dataset into account. This challenge is known as unsupervised anomaly detection and is addressed in many practical applications, for example in network intrusion detection, fraud detection as well as in the life science and medical domain. Dozens of algorithms have been proposed in this area, but unfortunately the research community still lacks a comparative universal evaluation as well as common publicly available datasets. These shortcomings are addressed in this study, where 19 different unsupervised anomaly detection algorithms are evaluated on 10 different datasets from multiple application domains. By publishing the source code and the datasets, this paper aims to be a new well-funded basis for unsupervised anomaly detection research. Additionally, this evaluation reveals the strengths and weaknesses of the different approaches for the first time. Besides the anomaly detection performance, computational effort, the impact of parameter settings as well as the global/local anomaly detection behavior is outlined. As a conclusion, we give an advise on algorithm selection for typical real-world tasks.
A New Moving Object Detection Method Based on Frame-difference and Background Subtraction
NASA Astrophysics Data System (ADS)
Guo, Jiajia; Wang, Junping; Bai, Ruixue; Zhang, Yao; Li, Yong
2017-09-01
Although many methods of moving object detection have been proposed, moving object extraction is still the core in video surveillance. However, with the complex scene in real world, false detection, missed detection and deficiencies resulting from cavities inside the body still exist. In order to solve the problem of incomplete detection for moving objects, a new moving object detection method combined an improved frame-difference and Gaussian mixture background subtraction is proposed in this paper. To make the moving object detection more complete and accurate, the image repair and morphological processing techniques which are spatial compensations are applied in the proposed method. Experimental results show that our method can effectively eliminate ghosts and noise and fill the cavities of the moving object. Compared to other four moving object detection methods which are GMM, VIBE, frame-difference and a literature's method, the proposed method improve the efficiency and accuracy of the detection.
Detection principles of biological and chemical FET sensors.
Kaisti, Matti
2017-12-15
The seminal importance of detecting ions and molecules for point-of-care tests has driven the search for more sensitive, specific, and robust sensors. Electronic detection holds promise for future miniaturized in-situ applications and can be integrated into existing electronic manufacturing processes and technology. The resulting small devices will be inherently well suited for multiplexed and parallel detection. In this review, different field-effect transistor (FET) structures and detection principles are discussed, including label-free and indirect detection mechanisms. The fundamental detection principle governing every potentiometric sensor is introduced, and different state-of-the-art FET sensor structures are reviewed. This is followed by an analysis of electrolyte interfaces and their influence on sensor operation. Finally, the fundamentals of different detection mechanisms are reviewed and some detection schemes are discussed. In the conclusion, current commercial efforts are briefly considered. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Liu, Wensong; Yang, Jie; Zhao, Jinqi; Shi, Hongtao; Yang, Le
2018-02-12
The traditional unsupervised change detection methods based on the pixel level can only detect the changes between two different times with same sensor, and the results are easily affected by speckle noise. In this paper, a novel method is proposed to detect change based on time-series data from different sensors. Firstly, the overall difference image of the time-series PolSAR is calculated by omnibus test statistics, and difference images between any two images in different times are acquired by R j test statistics. Secondly, the difference images are segmented with a Generalized Statistical Region Merging (GSRM) algorithm which can suppress the effect of speckle noise. Generalized Gaussian Mixture Model (GGMM) is then used to obtain the time-series change detection maps in the final step of the proposed method. To verify the effectiveness of the proposed method, we carried out the experiment of change detection using time-series PolSAR images acquired by Radarsat-2 and Gaofen-3 over the city of Wuhan, in China. Results show that the proposed method can not only detect the time-series change from different sensors, but it can also better suppress the influence of speckle noise and improve the overall accuracy and Kappa coefficient.
Age-related differences in gap detection: effects of task difficulty and cognitive ability.
Harris, Kelly C; Eckert, Mark A; Ahlstrom, Jayne B; Dubno, Judy R
2010-06-01
Differences in gap detection for younger and older adults have been shown to vary with the complexity of the task or stimuli, but the factors that contribute to these differences remain unknown. To address this question, we examined the extent to which age-related differences in processing speed and workload predicted age-related differences in gap detection. Gap detection thresholds were measured for 10 younger and 11 older adults in two conditions that varied in task complexity but used identical stimuli: (1) gap location fixed at the beginning, middle, or end of a noise burst and (2) gap location varied randomly from trial to trial from the beginning, middle, or end of the noise. We hypothesized that gap location uncertainty would place increased demands on cognitive and attentional resources and result in significantly higher gap detection thresholds for older but not younger adults. Overall, gap detection thresholds were lower for the middle location as compared to beginning and end locations and were lower for the fixed than the random condition. In general, larger age-related differences in gap detection were observed for more challenging conditions. That is, gap detection thresholds for older adults were significantly larger for the random condition than for the fixed condition when the gap was at the beginning and end locations but not the middle. In contrast, gap detection thresholds for younger adults were not significantly different for the random and fixed condition at any location. Subjective ratings of workload indicated that older adults found the gap detection task more mentally demanding than younger adults. Consistent with these findings, results of the Purdue Pegboard and Connections tests revealed age-related slowing of processing speed. Moreover, age group differences in workload and processing speed predicted gap detection in younger and older adults when gap location varied from trial to trial; these associations were not observed when gap location remained constant across trials. Taken together, these results suggest that age-related differences in complex measures of auditory temporal processing may be explained, in part, by age-related deficits in processing speed and attention. Copyright 2009 Elsevier B.V. All rights reserved.
Age-related differences in gap detection: Effects of task difficulty and cognitive ability
Harris, Kelly C.; Eckert, Mark A.; Ahlstrom, Jayne B.; Dubno, Judy R.
2009-01-01
Differences in gap detection for younger and older adults have been shown to vary with the complexity of the task or stimuli, but the factors that contribute to these differences remain unknown. To address this question, we examined the extent to which age-related differences in processing speed and workload predicted age-related differences in gap detection. Gap detection thresholds were measured for 10 younger and 11 older adults in two conditions that varied in task complexity but used identical stimuli: (1) gap location fixed at the beginning, middle, or end of a noise burst and (2) gap location varied randomly from trial to trial from the beginning, middle, or end of the noise. We hypothesized that gap location uncertainty would place increased demands on cognitive and attentional resources and result in significantly higher gap detection thresholds for older but not younger adults. Overall, gap detection thresholds were lower for the middle location as compared to beginning and end locations and were lower for the fixed than the random condition. In general, larger age-related differences in gap detection were observed for more challenging conditions. That is, gap detection thresholds for older adults were significantly larger for the random condition than for the fixed condition when the gap was at the beginning and end locations but not the middle. In contrast, gap detection thresholds for younger adults were not significantly different for the random and fixed condition at any location. Subjective ratings of workload indicated that older adults found the gap-detection task more mentally demanding than younger adults. Consistent with these findings, results of the Purdue Pegboard and Connections tests revealed age-related slowing of processing speed. Moreover, age group differences in workload and processing speed predicted gap detection in younger and older adults when gap location varied from trial to trial; these associations were not observed when gap location remained constant across trials. Taken together, these results suggest that age-related differences in complex measures of auditory temporal processing may be explained, in part, by age-related deficits in processing speed and attention. PMID:19800958
Choice of Grating Orientation for Evaluation of Peripheral Vision
Venkataraman, Abinaya Priya; Winter, Simon; Rosén, Robert; Lundström, Linda
2016-01-01
ABSTRACT Purpose Peripheral resolution acuity depends on the orientation of the stimuli. However, it is uncertain if such a meridional effect also exists for peripheral detection tasks because they are affected by optical errors. Knowledge of the quantitative differences in acuity for different grating orientations is crucial for choosing the appropriate stimuli for evaluations of peripheral resolution and detection tasks. We assessed resolution and detection thresholds for different grating orientations in the peripheral visual field. Methods Resolution and detection thresholds were evaluated for gratings of four different orientations in eight different visual field meridians in the 20-deg visual field in white light. Detection measurements in monochromatic light (543 nm; bandwidth, 10 nm) were also performed to evaluate the effects of chromatic aberration on the meridional effect. A combination of trial lenses and adaptive optics system was used to correct the monochromatic lower- and higher-order aberrations. Results For both resolution and detection tasks, gratings parallel to the visual field meridian had better threshold compared with the perpendicular gratings, whereas the two oblique gratings had similar thresholds. The parallel and perpendicular grating acuity differences for resolution and detection tasks were 0.16 logMAR and 0.11 logMAD, respectively. Elimination of chromatic errors did not affect the meridional preference in detection acuity. Conclusions Similar to peripheral resolution, detection also shows a meridional effect that appears to have a neural origin. The threshold difference seen for parallel and perpendicular gratings suggests the use of two oblique gratings as stimuli in alternative forced-choice procedures for peripheral vision evaluation to reduce measurement variation. PMID:26889822
Choice of Grating Orientation for Evaluation of Peripheral Vision.
Venkataraman, Abinaya Priya; Winter, Simon; Rosén, Robert; Lundström, Linda
2016-06-01
Peripheral resolution acuity depends on the orientation of the stimuli. However, it is uncertain if such a meridional effect also exists for peripheral detection tasks because they are affected by optical errors. Knowledge of the quantitative differences in acuity for different grating orientations is crucial for choosing the appropriate stimuli for evaluations of peripheral resolution and detection tasks. We assessed resolution and detection thresholds for different grating orientations in the peripheral visual field. Resolution and detection thresholds were evaluated for gratings of four different orientations in eight different visual field meridians in the 20-deg visual field in white light. Detection measurements in monochromatic light (543 nm; bandwidth, 10 nm) were also performed to evaluate the effects of chromatic aberration on the meridional effect. A combination of trial lenses and adaptive optics system was used to correct the monochromatic lower- and higher-order aberrations. For both resolution and detection tasks, gratings parallel to the visual field meridian had better threshold compared with the perpendicular gratings, whereas the two oblique gratings had similar thresholds. The parallel and perpendicular grating acuity differences for resolution and detection tasks were 0.16 logMAR and 0.11 logMAD, respectively. Elimination of chromatic errors did not affect the meridional preference in detection acuity. Similar to peripheral resolution, detection also shows a meridional effect that appears to have a neural origin. The threshold difference seen for parallel and perpendicular gratings suggests the use of two oblique gratings as stimuli in alternative forced-choice procedures for peripheral vision evaluation to reduce measurement variation.
Individual differences in conflict detection during reasoning.
Frey, Darren; Johnson, Eric D; De Neys, Wim
2018-05-01
Decades of reasoning and decision-making research have established that human judgment is often biased by intuitive heuristics. Recent "error" or bias detection studies have focused on reasoners' abilities to detect whether their heuristic answer conflicts with logical or probabilistic principles. A key open question is whether there are individual differences in this bias detection efficiency. Here we present three studies in which co-registration of different error detection measures (confidence, response time and confidence response time) allowed us to assess bias detection sensitivity at the individual participant level in a range of reasoning tasks. The results indicate that although most individuals show robust bias detection, as indexed by increased latencies and decreased confidence, there is a subgroup of reasoners who consistently fail to do so. We discuss theoretical and practical implications for the field.
Thermographic techniques and adapted algorithms for automatic detection of foreign bodies in food
NASA Astrophysics Data System (ADS)
Meinlschmidt, Peter; Maergner, Volker
2003-04-01
At the moment foreign substances in food are detected mainly by using mechanical and optical methods as well as ultrasonic technique and than they are removed from the further process. These techniques detect a large portion of the foreign substances due to their different mass (mechanical sieving), their different colour (optical method) and their different surface density (ultrasonic detection). Despite the numerous different methods a considerable portion of the foreign substances remain undetected. In order to recognise materials still undetected, a complementary detection method would be desirable removing the foreign substances not registered by the a.m. methods from the production process. In a project with 13 partner from the food industry, the Fraunhofer - Institut für Holzforschung (WKI) and the Technische Unsiversität are trying to adapt thermography for the detection of foreign bodies in the food industry. After the initial tests turned out to be very promising for the differentiation of food stuffs and foreign substances, more and detailed investigation were carried out to develop suitable algorithms for automatic detection of foreign bodies. In order to achieve -besides the mere visual detection of foreign substances- also an automatic detection under production conditions, numerous experiences in image processing and pattern recognition are exploited. Results for the detection of foreign bodies will be presented at the conference showing the different advantages and disadvantages of using grey - level, statistical and morphological image processing techniques.
NASA Astrophysics Data System (ADS)
Wardani, Devy P.; Arifin, Muhammad; Suharyadi, Edi; Abraha, Kamsul
2015-05-01
Gelatin is a biopolymer derived from collagen that is widely used in food and pharmaceutical products. Due to some religion restrictions and health issues regarding the gelatin consumption which is extracted from certain species, it is necessary to establish a robust, reliable, sensitive and simple quantitative method to detect gelatin from different parent collagen species. To the best of our knowledge, there has not been a gelatin differentiation method based on optical sensor that could detect gelatin from different species quantitatively. Surface plasmon resonance (SPR) based biosensor is known to be a sensitive, simple and label free optical method for detecting biomaterials that is able to do quantitative detection. Therefore, we have utilized SPR-based biosensor to detect the differentiation between bovine and porcine gelatin in various concentration, from 0% to 10% (w/w). Here, we report the ability of SPR-based biosensor to detect difference between both gelatins, its sensitivity toward the gelatin concentration change, its reliability and limit of detection (LOD) and limit of quantification (LOQ) of the sensor. The sensor's LOD and LOQ towards bovine gelatin concentration are 0.38% and 1.26% (w/w), while towards porcine gelatin concentration are 0.66% and 2.20% (w/w), respectively. The results show that SPR-based biosensor is a promising tool for detecting gelatin from different raw materials quantitatively.
A Comparative Evaluation of Unsupervised Anomaly Detection Algorithms for Multivariate Data
Goldstein, Markus; Uchida, Seiichi
2016-01-01
Anomaly detection is the process of identifying unexpected items or events in datasets, which differ from the norm. In contrast to standard classification tasks, anomaly detection is often applied on unlabeled data, taking only the internal structure of the dataset into account. This challenge is known as unsupervised anomaly detection and is addressed in many practical applications, for example in network intrusion detection, fraud detection as well as in the life science and medical domain. Dozens of algorithms have been proposed in this area, but unfortunately the research community still lacks a comparative universal evaluation as well as common publicly available datasets. These shortcomings are addressed in this study, where 19 different unsupervised anomaly detection algorithms are evaluated on 10 different datasets from multiple application domains. By publishing the source code and the datasets, this paper aims to be a new well-funded basis for unsupervised anomaly detection research. Additionally, this evaluation reveals the strengths and weaknesses of the different approaches for the first time. Besides the anomaly detection performance, computational effort, the impact of parameter settings as well as the global/local anomaly detection behavior is outlined. As a conclusion, we give an advise on algorithm selection for typical real-world tasks. PMID:27093601
Automatic QRS complex detection using two-level convolutional neural network.
Xiang, Yande; Lin, Zhitao; Meng, Jianyi
2018-01-29
The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especially in the transform domains. In addition, fixed features and parameters are not suitable for detecting various kinds of QRS complexes under different circumstances. In this study, based on 1-D convolutional neural network (CNN), an accurate method for QRS complex detection is proposed. The CNN consists of object-level and part-level CNNs for extracting different grained ECG morphological features automatically. All the extracted morphological features are used by multi-layer perceptron (MLP) for QRS complex detection. Additionally, a simple ECG signal preprocessing technique which only contains difference operation in temporal domain is adopted. Based on the MIT-BIH arrhythmia (MIT-BIH-AR) database, the proposed detection method achieves overall sensitivity Sen = 99.77%, positive predictivity rate PPR = 99.91%, and detection error rate DER = 0.32%. In addition, the performance variation is performed according to different signal-to-noise ratio (SNR) values. An automatic QRS detection method using two-level 1-D CNN and simple signal preprocessing technique is proposed for QRS complex detection. Compared with the state-of-the-art QRS complex detection approaches, experimental results show that the proposed method acquires comparable accuracy.
Jang, J; Seo, J K
2015-06-01
This paper describes a multiple background subtraction method in frequency difference electrical impedance tomography (fdEIT) to detect an admittivity anomaly from a high-contrast background conductivity distribution. The proposed method expands the use of the conventional weighted frequency difference EIT method, which has been used limitedly to detect admittivity anomalies in a roughly homogeneous background. The proposed method can be viewed as multiple weighted difference imaging in fdEIT. Although the spatial resolutions of the output images by fdEIT are very low due to the inherent ill-posedness, numerical simulations and phantom experiments of the proposed method demonstrate its feasibility to detect anomalies. It has potential application in stroke detection in a head model, which is highly heterogeneous due to the skull.
Reitsma, Marit; Bastiaan-Net, Shanna; Sijbrandij, Lutske; de Weert, Evelien; Sforza, Stefano; Gerth van Wijk, Roy; Savelkoul, Huub F J; de Jong, Nicolette W; Wichers, Harry J
2018-04-01
The protein content and allergen composition was studied of cashews from 8 different origins (Benin, Brazil, Ghana, India, Ivory Coast, Mozambique, Tanzania, Vietnam), subjected to different in-shell heat treatments (steamed, fried, drum-roasted). On 2D electrophoresis, 9 isoforms of Ana o 1, 29 isoforms of Ana o 2 (11 of the acidic subunit, 18 of the basic subunit), and 8 isoforms of the large subunit of Ana o 3 were tentatively identified. Based on 1D and 2D electrophoresis, no difference in allergen content (Ana o 1, 2, 3) was detected between the cashews of different origins (P > 0.5), some small but significant differences were detected in allergen solubility between differently heated cashews. No major differences in N- and C-terminal microheterogeneity of Ana o 3 were detected between cashews of different origins. Between the different heat treatments, no difference was detected in glycation, pepsin digestibility, or IgE binding of the cashew proteins. © 2018 Institute of Food Technologists®.
Development of Temperature Sensitive Paints for the Detection of Small Temperature Differences
NASA Technical Reports Server (NTRS)
Oglesby, Donald M.; Upchurch, Billy T.; Sealey, Bradley S.; Leighty, Bradley D.; Burkett, Cecil G., Jr.; Jalali, Amir
1997-01-01
Temperature sensitive paints (TSP s) have recently been used to detect small temperature differences on aerodynamic model surfaces. These types of applications impose stringent performance requirements on a paint system. The TSP s must operate over a broad temperature range, must be physically robust (cannot chip or peel), must be polishable to at least the smoothness of the model surface, and must have sufficient sensitivity to detect small temperature differences. TSP coatings based on the use of metal complexes in polymer binders were developed at NASA Langley Research Center which meet most of the requirements for detection of small temperature differences under severe environmental conditions.
Detecting and treating occlusal caries lesions: a cost-effectiveness analysis.
Schwendicke, F; Stolpe, M; Meyer-Lueckel, H; Paris, S
2015-02-01
The health gains and costs resulting from using different caries detection strategies might not only depend on the accuracy of the used method but also the treatment emanating from its use in different populations. We compared combinations of visual-tactile, radiographic, or laser-fluorescence-based detection methods with 1 of 3 treatments (non-, micro-, and invasive treatment) initiated at different cutoffs (treating all or only dentinal lesions) in populations with low or high caries prevalence. A Markov model was constructed to follow an occlusal surface in a permanent molar in an initially 12-y-old male German patient over his lifetime. Prevalence data and transition probabilities were extracted from the literature, while validity parameters of different methods were synthesized or obtained from systematic reviews. Microsimulations were performed to analyze the model, assuming a German health care setting and a mixed public-private payer perspective. Radiographic and fluorescence-based methods led to more overtreatments, especially in populations with low prevalence. For the latter, combining visual-tactile or radiographic detection with microinvasive treatment retained teeth longest (mean 66 y) at lowest costs (329 and 332 Euro, respectively), while combining radiographic or fluorescence-based detections with invasive treatment was the least cost-effective (<60 y, >700 Euro). In populations with high prevalence, combining radiographic detection with microinvasive treatment was most cost-effective (63 y, 528 Euro), while sensitive detection methods combined with invasive treatments were again the least cost-effective (<59 y, >690 Euro). The suitability of detection methods differed significantly between populations, and the cost-effectiveness was greatly influenced by the treatment initiated after lesion detection. The accuracy of a detection method relative to a "gold standard" did not automatically convey into better health or reduced costs. Detection methods should be evaluated not only against their criterion validity but also the long-term effects resulting from their use in different populations. © International & American Associations for Dental Research 2014.
NASA Astrophysics Data System (ADS)
Han, Minah; Jang, Hanjoo; Baek, Jongduk
2018-03-01
We investigate lesion detectability and its trends for different noise structures in single-slice and multislice CBCT images with anatomical background noise. Anatomical background noise is modeled using a power law spectrum of breast anatomy. Spherical signal with a 2 mm diameter is used for modeling a lesion. CT projection data are acquired by the forward projection and reconstructed by the Feldkamp-Davis-Kress algorithm. To generate different noise structures, two types of reconstruction filters (Hanning and Ram-Lak weighted ramp filters) are used in the reconstruction, and the transverse and longitudinal planes of reconstructed volume are used for detectability evaluation. To evaluate single-slice images, the central slice, which contains the maximum signal energy, is used. To evaluate multislice images, central nine slices are used. Detectability is evaluated using human and model observer studies. For model observer, channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels are used. For all noise structures, detectability by a human observer is higher for multislice images than single-slice images, and the degree of detectability increase in multislice images depends on the noise structure. Variation in detectability for different noise structures is reduced in multislice images, but detectability trends are not much different between single-slice and multislice images. The CHO with D-DOG channels predicts detectability by a human observer well for both single-slice and multislice images.
Design of the Detector II: A CMOS Gate Array for the Study of Concurrent Error Detection Techniques.
1987-07-01
detection schemes and temporary failures. The circuit consists- or of six different adders with concurrent error detection schemes . The error detection... schemes are - simple duplication, duplication with functional dual implementation, duplication with different &I [] .6implementations, two-rail encoding...THE SYSTEM. .. .... ...... ...... ...... 5 7. DESIGN OF CED SCHEMES .. ... ...... ...... ........ 7 7.1 Simple Duplication
Object Detection in Natural Backgrounds Predicted by Discrimination Performance and Models
NASA Technical Reports Server (NTRS)
Ahumada, A. J., Jr.; Watson, A. B.; Rohaly, A. M.; Null, Cynthia H. (Technical Monitor)
1995-01-01
In object detection, an observer looks for an object class member in a set of backgrounds. In discrimination, an observer tries to distinguish two images. Discrimination models predict the probability that an observer detects a difference between two images. We compare object detection and image discrimination with the same stimuli by: (1) making stimulus pairs of the same background with and without the target object and (2) either giving many consecutive trials with the same background (discrimination) or intermixing the stimuli (object detection). Six images of a vehicle in a natural setting were altered to remove the vehicle and mixed with the original image in various proportions. Detection observers rated the images for vehicle presence. Discrimination observers rated the images for any difference from the background image. Estimated detectabilities of the vehicles were found by maximizing the likelihood of a Thurstone category scaling model. The pattern of estimated detectabilities is similar for discrimination and object detection, and is accurately predicted by a Cortex Transform discrimination model. Predictions of a Contrast- Sensitivity- Function filter model and a Root-Mean-Square difference metric based on the digital image values are less accurate. The discrimination detectabilities averaged about twice those of object detection.
Got power? A systematic review of sample size adequacy in health professions education research.
Cook, David A; Hatala, Rose
2015-03-01
Many education research studies employ small samples, which in turn lowers statistical power. We re-analyzed the results of a meta-analysis of simulation-based education to determine study power across a range of effect sizes, and the smallest effect that could be plausibly excluded. We systematically searched multiple databases through May 2011, and included all studies evaluating simulation-based education for health professionals in comparison with no intervention or another simulation intervention. Reviewers working in duplicate abstracted information to calculate standardized mean differences (SMD's). We included 897 original research studies. Among the 627 no-intervention-comparison studies the median sample size was 25. Only two studies (0.3%) had ≥80% power to detect a small difference (SMD > 0.2 standard deviations) and 136 (22%) had power to detect a large difference (SMD > 0.8). 110 no-intervention-comparison studies failed to find a statistically significant difference, but none excluded a small difference and only 47 (43%) excluded a large difference. Among 297 studies comparing alternate simulation approaches the median sample size was 30. Only one study (0.3%) had ≥80% power to detect a small difference and 79 (27%) had power to detect a large difference. Of the 128 studies that did not detect a statistically significant effect, 4 (3%) excluded a small difference and 91 (71%) excluded a large difference. In conclusion, most education research studies are powered only to detect effects of large magnitude. For most studies that do not reach statistical significance, the possibility of large and important differences still exists.
NASA Astrophysics Data System (ADS)
Hartung, Christine; Spraul, Raphael; Schuchert, Tobias
2017-10-01
Wide area motion imagery (WAMI) acquired by an airborne multicamera sensor enables continuous monitoring of large urban areas. Each image can cover regions of several square kilometers and contain thousands of vehicles. Reliable vehicle tracking in this imagery is an important prerequisite for surveillance tasks, but remains challenging due to low frame rate and small object size. Most WAMI tracking approaches rely on moving object detections generated by frame differencing or background subtraction. These detection methods fail when objects slow down or stop. Recent approaches for persistent tracking compensate for missing motion detections by combining a detection-based tracker with a second tracker based on appearance or local context. In order to avoid the additional complexity introduced by combining two trackers, we employ an alternative single tracker framework that is based on multiple hypothesis tracking and recovers missing motion detections with a classifierbased detector. We integrate an appearance-based similarity measure, merge handling, vehicle-collision tests, and clutter handling to adapt the approach to the specific context of WAMI tracking. We apply the tracking framework on a region of interest of the publicly available WPAFB 2009 dataset for quantitative evaluation; a comparison to other persistent WAMI trackers demonstrates state of the art performance of the proposed approach. Furthermore, we analyze in detail the impact of different object detection methods and detector settings on the quality of the output tracking results. For this purpose, we choose four different motion-based detection methods that vary in detection performance and computation time to generate the input detections. As detector parameters can be adjusted to achieve different precision and recall performance, we combine each detection method with different detector settings that yield (1) high precision and low recall, (2) high recall and low precision, and (3) best f-score. Comparing the tracking performance achieved with all generated sets of input detections allows us to quantify the sensitivity of the tracker to different types of detector errors and to derive recommendations for detector and parameter choice.
A comparison of moving object detection methods for real-time moving object detection
NASA Astrophysics Data System (ADS)
Roshan, Aditya; Zhang, Yun
2014-06-01
Moving object detection has a wide variety of applications from traffic monitoring, site monitoring, automatic theft identification, face detection to military surveillance. Many methods have been developed across the globe for moving object detection, but it is very difficult to find one which can work globally in all situations and with different types of videos. The purpose of this paper is to evaluate existing moving object detection methods which can be implemented in software on a desktop or laptop, for real time object detection. There are several moving object detection methods noted in the literature, but few of them are suitable for real time moving object detection. Most of the methods which provide for real time movement are further limited by the number of objects and the scene complexity. This paper evaluates the four most commonly used moving object detection methods as background subtraction technique, Gaussian mixture model, wavelet based and optical flow based methods. The work is based on evaluation of these four moving object detection methods using two (2) different sets of cameras and two (2) different scenes. The moving object detection methods have been implemented using MatLab and results are compared based on completeness of detected objects, noise, light change sensitivity, processing time etc. After comparison, it is observed that optical flow based method took least processing time and successfully detected boundary of moving objects which also implies that it can be implemented for real-time moving object detection.
Bayesian methods for outliers detection in GNSS time series
NASA Astrophysics Data System (ADS)
Qianqian, Zhang; Qingming, Gui
2013-07-01
This article is concerned with the problem of detecting outliers in GNSS time series based on Bayesian statistical theory. Firstly, a new model is proposed to simultaneously detect different types of outliers based on the conception of introducing different types of classification variables corresponding to the different types of outliers; the problem of outlier detection is converted into the computation of the corresponding posterior probabilities, and the algorithm for computing the posterior probabilities based on standard Gibbs sampler is designed. Secondly, we analyze the reasons of masking and swamping about detecting patches of additive outliers intensively; an unmasking Bayesian method for detecting additive outlier patches is proposed based on an adaptive Gibbs sampler. Thirdly, the correctness of the theories and methods proposed above is illustrated by simulated data and then by analyzing real GNSS observations, such as cycle slips detection in carrier phase data. Examples illustrate that the Bayesian methods for outliers detection in GNSS time series proposed by this paper are not only capable of detecting isolated outliers but also capable of detecting additive outlier patches. Furthermore, it can be successfully used to process cycle slips in phase data, which solves the problem of small cycle slips.
Spectrotemporal Modulation Detection and Speech Perception by Cochlear Implant Users
Won, Jong Ho; Moon, Il Joon; Jin, Sunhwa; Park, Heesung; Woo, Jihwan; Cho, Yang-Sun; Chung, Won-Ho; Hong, Sung Hwa
2015-01-01
Spectrotemporal modulation (STM) detection performance was examined for cochlear implant (CI) users. The test involved discriminating between an unmodulated steady noise and a modulated stimulus. The modulated stimulus presents frequency modulation patterns that change in frequency over time. In order to examine STM detection performance for different modulation conditions, two different temporal modulation rates (5 and 10 Hz) and three different spectral modulation densities (0.5, 1.0, and 2.0 cycles/octave) were employed, producing a total 6 different STM stimulus conditions. In order to explore how electric hearing constrains STM sensitivity for CI users differently from acoustic hearing, normal-hearing (NH) and hearing-impaired (HI) listeners were also tested on the same tasks. STM detection performance was best in NH subjects, followed by HI subjects. On average, CI subjects showed poorest performance, but some CI subjects showed high levels of STM detection performance that was comparable to acoustic hearing. Significant correlations were found between STM detection performance and speech identification performance in quiet and in noise. In order to understand the relative contribution of spectral and temporal modulation cues to speech perception abilities for CI users, spectral and temporal modulation detection was performed separately and related to STM detection and speech perception performance. The results suggest that that slow spectral modulation rather than slow temporal modulation may be important for determining speech perception capabilities for CI users. Lastly, test–retest reliability for STM detection was good with no learning. The present study demonstrates that STM detection may be a useful tool to evaluate the ability of CI sound processing strategies to deliver clinically pertinent acoustic modulation information. PMID:26485715
Occurrence of Pesticides in Ground Water of Wyoming, 1995-2006
Bartos, Timothy T.; Eddy-Miller, Cheryl A.; Hallberg, Laura L.
2009-01-01
Little existing information was available describing pesticide occurrence in ground water of Wyoming, so the U.S. Geological Survey, in cooperation with the Wyoming Department of Agriculture and the Wyoming Department of Environmental Quality on behalf of the Wyoming Ground-water and Pesticides Strategy Committee, collected ground-water samples twice (during late summer/early fall and spring) from 296 wells during 1995-2006 to characterize pesticide occurrence. Sampling focused on the State's ground water that was mapped as the most vulnerable to pesticide contamination because of either inherent hydrogeologic sensitivity (for example, shallow water table or highly permeable aquifer materials) or a combination of sensitivity and associated land use. Because of variations in reporting limits among different compounds and for the same compound during this study, pesticide detections were recensored to two different assessment levels to facilitate qualitative and quantitative examination of pesticide detection frequencies - a common assessment level (CAL) of 0.07 microgram per liter and an assessment level that differed by compound, referred to herein as a compound-specific assessment level (CSAL). Because of severe data censoring (fewer than 50 percent of the data are greater than laboratory reporting limits), categorical statistical methods were used exclusively for quantitative comparisons of pesticide detection frequencies between seasons and among various natural and anthropogenic (human-related) characteristics. One or more pesticides were detected at concentrations greater than the CAL in water from about 23 percent of wells sampled in the fall and from about 22 percent of wells sampled in the spring. Mixtures of two or more pesticides occurred at concentrations greater than the CAL in about 9 percent of wells sampled in the fall and in about 10 percent of wells sampled in the spring. At least 74 percent of pesticides detected were classified as herbicides. Considering only detections using the CAL, triazine pesticides were detected much more frequently than all other pesticide classes, and the number of different pesticides classified as triazines was the largest of all classes. More pesticides were detected at concentrations greater than the CSALs in water from wells sampled in the fall (28 different pesticides) than in the spring (21 different pesticides). Many pesticides were detected infrequently as nearly one-half of pesticides detected in the fall and spring at concentrations greater than the CSALs were detected only in one well. Using the CSALs for pesticides analyzed for in 11 or more wells, only five pesticides (atrazine, prometon, tebuthiuron, picloram, and 3,4-dichloroaniline, listed in order of decreasing detection frequency) were each detected in water from more than 5 percent of sampled wells. Atrazine was the pesticide detected most frequently at concentrations greater than the CSAL. Concentrations of detected pesticides generally were small (less than 1 microgram per liter), although many infrequent detections at larger concentrations were noted. All detected pesticide concentrations were smaller than U.S. Environmental Protection Agency (USEPA) drinking-water standards or applicable health advisories. Most concentrations were at least an order of magnitude smaller; however, many pesticides did not have standards or advisories. The largest percentage of pesticide detections and the largest number of different pesticides detected were in samples from wells located in the Bighorn Basin and High Plains/ Casper Arch geographic areas of north-central and southeastern Wyoming. Prometon was the only pesticide detected in all eight geographic areas of the State. Pesticides were detected much more frequently in samples from wells located in predominantly urban areas than in samples from wells located in predominantly agricultural or mixed areas. Pesticides were detected distinctly less often in sa
Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration
2007-09-01
March 17, 2005. The seismic signals from both master and detected events are followed by infrasound arrivals. Note the long duration of the...correlation coefficient traces with a significant array -gain. A detected event that is co-located with the master event will record the same time-difference...estimating the detection threshold reduction for a range of highly repeating seismic sources using arrays of different configurations and at different
Lahou, Evy; Uyttendaele, Mieke
2014-01-01
Listeria monocytogenes can adhere to different types of food contact surfaces within a food processing environment. Therefore, environmental sampling devices should be capable of detecting unacceptable contamination. In this study, a sponge-stick, foam spatula and an environmental swab were evaluated on their ability to detect low concentrations of L. monocytogenes on different types of food contact surfaces. A cocktail of four L. monocytogenes serotypes was inoculated with a concentration of 100 CFU/250 cm2 onto stainless steel (SS), high density polyethylene (HDPE) and rubber surfaces in a 250 cm2 area. Immediately after inoculation and after 1 h exposure, the surfaces were swabbed with the different swabbing devices. The results of the study show only minor differences in the ability of the swabbing devices to detect L. monocytogenes. All devices were capable to detect the contamination immediately after inoculation. However, when the surfaces were allowed to air-dry for 1 h, L. monocytogenes was undetected in 11.1% of the samples (n = 27) with the sponge stick, in 7.4% of the samples (n = 27) with the foam spatula and in 3.7% of the samples (n = 27) with the environmental swab, especially on SS surfaces. The detection ability of the different devices for L. monocytogenes can be concluded to be rather high on different types of food contact surfaces. PMID:24406663
Salt taste after bariatric surgery and weight loss in obese persons
Maedge, Julia; Lam, Linda; Blasche, Gerhard; Shakeri-Leidenmühler, Soheila; Kundi, Michael; Ludvik, Bernhard; Langer, Felix B.; Prager, Gerhard; Schindler, Karin; Dürrschmid, Klaus
2016-01-01
Background. Little is known about the perception of salty taste in obese patients, especially after bariatric surgery. Therefore, the aim of this study was to analyse possible differences in salt detection thresholds and preferences for foods differing in salt content in obese persons before and after bariatric surgery with weight loss compared to non-obese individuals. Methods. Sodium chloride detection thresholds and liking for cream soups with different salt concentrations were studied with established tests. Moreover, a brief salt food questionnaire was assessed to identify the usage and awareness of salt in food. Results. The results showed similar mean sodium chloride detection thresholds between non-obese and obese participants. After bariatric surgery a non-significant increase in the salt detection threshold was observed in the obese patients (mean ± SD: 0.44 ± 0.24 g NaCl/L before OP vs. 0.64 ± 0.47 g NaCl/L after OP, p = 0.069). Cream soup liking between controls and obese patients were not significantly different. However, significant sex specific differences were detected with the tested women not liking the soups (p < 0.001). Results from the food questionnaire were similar between the groups. Conclusion. No differences between non-obese persons and obese patients were shown regarding the salt detection threshold. However, due to highly significant differences in soup liking, sex should be taken into consideration when conducting similar sensory studies. PMID:27330856
C. John Ralph
1995-01-01
I compared the mean level of detections of Marbled Murrelets by month over five years at three inland sites in northern California. These areas all have relatively high levels of detections. There were no significant differences in mean detection levels year to year at any site, and for any month with the exception of April at one site. This lack of evidence for...
Asadollahi, Ali; Endler, Frank; Nelken, Israel; Wagner, Hermann
2010-08-01
Humans and animals are able to detect signals in noisy environments. Detection improves when the noise and the signal have different interaural phase relationships. The resulting improvement in detection threshold is called the binaural masking level difference. We investigated neural mechanisms underlying the release from masking in the inferior colliculus of barn owls in low-frequency and high-frequency neurons. A tone (signal) was presented either with the same interaural time difference as the noise (masker) or at a 180 degrees phase shift as compared with the interaural time difference of the noise. The changes in firing rates induced by the addition of a signal of increasing level while masker level was kept constant was well predicted by the relative responses to the masker and signal alone. In many cases, the response at the highest signal levels was dominated by the response to the signal alone, in spite of a significant response to the masker at low signal levels, suggesting the presence of occlusion. Detection thresholds and binaural masking level differences were widely distributed. The amount of release from masking increased with increasing masker level. Narrowly tuned neurons in the central nucleus of the inferior colliculus had detection thresholds that were lower than or similar to those of broadly tuned neurons in the external nucleus of the inferior colliculus. Broadly tuned neurons exhibited higher masking level differences than narrowband neurons. These data suggest that detection has different spectral requirements from localization.
Power spectrum weighted edge analysis for straight edge detection in images
NASA Astrophysics Data System (ADS)
Karvir, Hrishikesh V.; Skipper, Julie A.
2007-04-01
Most man-made objects provide characteristic straight line edges and, therefore, edge extraction is a commonly used target detection tool. However, noisy images often yield broken edges that lead to missed detections, and extraneous edges that may contribute to false target detections. We present a sliding-block approach for target detection using weighted power spectral analysis. In general, straight line edges appearing at a given frequency are represented as a peak in the Fourier domain at a radius corresponding to that frequency, and a direction corresponding to the orientation of the edges in the spatial domain. Knowing the edge width and spacing between the edges, a band-pass filter is designed to extract the Fourier peaks corresponding to the target edges and suppress image noise. These peaks are then detected by amplitude thresholding. The frequency band width and the subsequent spatial filter mask size are variable parameters to facilitate detection of target objects of different sizes under known imaging geometries. Many military objects, such as trucks, tanks and missile launchers, produce definite signatures with parallel lines and the algorithm proves to be ideal for detecting such objects. Moreover, shadow-casting objects generally provide sharp edges and are readily detected. The block operation procedure offers advantages of significant reduction in noise influence, improved edge detection, faster processing speed and versatility to detect diverse objects of different sizes in the image. With Scud missile launcher replicas as target objects, the method has been successfully tested on terrain board test images under different backgrounds, illumination and imaging geometries with cameras of differing spatial resolution and bit-depth.
Detection of maize kernels breakage rate based on K-means clustering
NASA Astrophysics Data System (ADS)
Yang, Liang; Wang, Zhuo; Gao, Lei; Bai, Xiaoping
2017-04-01
In order to optimize the recognition accuracy of maize kernels breakage detection and improve the detection efficiency of maize kernels breakage, this paper using computer vision technology and detecting of the maize kernels breakage based on K-means clustering algorithm. First, the collected RGB images are converted into Lab images, then the original images clarity evaluation are evaluated by the energy function of Sobel 8 gradient. Finally, the detection of maize kernels breakage using different pixel acquisition equipments and different shooting angles. In this paper, the broken maize kernels are identified by the color difference between integrity kernels and broken kernels. The original images clarity evaluation and different shooting angles are taken to verify that the clarity and shooting angles of the images have a direct influence on the feature extraction. The results show that K-means clustering algorithm can distinguish the broken maize kernels effectively.
Comparison of four different methods for detection of biofilm formation by uropathogens.
Panda, Pragyan Swagatika; Chaudhary, Uma; Dube, Surya K
2016-01-01
Urinary tract infection (UTI) is one of the most common infectious diseases encountered in clinical practice. Emerging resistance of the uropathogens to the antimicrobial agents due to biofilm formation is a matter of concern while treating symptomatic UTI. However, studies comparing different methods for detection of biofilm by uropathogens are scarce. To compare four different methods for detection of biofilm formation by uropathogens. Prospective observational study conducted in a tertiary care hospital. Totally 300 isolates from urinary samples were analyzed for biofilm formation by four methods, that is, tissue culture plate (TCP) method, tube method (TM), Congo Red Agar (CRA) method and modified CRA (MCRA) method. Chi-square test was applied when two or more set of variables were compared. P < 0.05 considered as statistically significant. Considering TCP to be a gold standard method for our study we calculated other statistical parameters. The rate of biofilm detection was 45.6%, 39.3% and 11% each by TCP, TM, CRA and MCRA methods, respectively. The difference between TCP and only CRA/MCRA was significant, but not that between TCP and TM. There was no difference in the rate of biofilm detection between CRA and MCRA in other isolates, but MCRA is superior to CRA for detection of the staphylococcal biofilm formation. TCP method is the ideal method for detection of bacterial biofilm formation by uropathogens. MCRA method is superior only to CRA for detection of staphylococcal biofilm formation.
A comparison of public datasets for acceleration-based fall detection.
Igual, Raul; Medrano, Carlos; Plaza, Inmaculada
2015-09-01
Falls are one of the leading causes of mortality among the older population, being the rapid detection of a fall a key factor to mitigate its main adverse health consequences. In this context, several authors have conducted studies on acceleration-based fall detection using external accelerometers or smartphones. The published detection rates are diverse, sometimes close to a perfect detector. This divergence may be explained by the difficulties in comparing different fall detection studies in a fair play since each study uses its own dataset obtained under different conditions. In this regard, several datasets have been made publicly available recently. This paper presents a comparison, to the best of our knowledge for the first time, of these public fall detection datasets in order to determine whether they have an influence on the declared performances. Using two different detection algorithms, the study shows that the performances of the fall detection techniques are affected, to a greater or lesser extent, by the specific datasets used to validate them. We have also found large differences in the generalization capability of a fall detector depending on the dataset used for training. In fact, the performance decreases dramatically when the algorithms are tested on a dataset different from the one used for training. Other characteristics of the datasets like the number of training samples also have an influence on the performance while algorithms seem less sensitive to the sampling frequency or the acceleration range. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Label-Free Direct Detection of miRNAs with Poly-Silicon Nanowire Biosensors
Gong, Changguo; Qi, Jiming; Xiao, Han; Jiang, Bin; Zhao, Yulan
2015-01-01
Background The diagnostic and prognostic value of microRNAs (miRNAs) in a variety of diseases is promising. The novel silicon nanowire (SiNW) biosensors have advantages in molecular detection because of their high sensitivity and fast response. In this study, poly-crystalline silicon nanowire field-effect transistor (poly-SiNW FET) device was developed to achieve specific and ultrasensitive detection of miRNAs without labeling and amplification. Methods The poly-SiNW FET was fabricated by a top–down Complementary Metal Oxide Semiconductor (CMOS) wafer fabrication based technique. Single strand DNA (ssDNA) probe was bind to the surface of the poly-SiNW device which was silanated and aldehyde-modified. By comparing the difference of resistance value before and after ssDNA and miRNA hybridization, poly-SiNW device can be used to detect standard and real miRNA samples. Results Poly-SiNW device with different structures (different line width and different pitch) was applied to detect standard Let-7b sample with a detection limitation of 1 fM. One-base mismatched sequence could be distinguished meanwhile. Furthermore, these poly-SiNW arrays can detect snRNA U6 in total RNA samples extracted from HepG2 cells with a detection limitation of 0.2 μg/mL. In general, structures with pitch showed better results than those without pitch in detection of both Let-7b and snRNA U6. Moreover, structures with smaller pitch showed better detection efficacy. Conclusion Our findings suggest that poly-SiNW arrays could detect standard and real miRNA sample without labeling or amplification. Poly-SiNW biosensor device is promising for miRNA detection. PMID:26709827
SAR Image Change Detection Based on Fuzzy Markov Random Field Model
NASA Astrophysics Data System (ADS)
Zhao, J.; Huang, G.; Zhao, Z.
2018-04-01
Most existing SAR image change detection algorithms only consider single pixel information of different images, and not consider the spatial dependencies of image pixels. So the change detection results are susceptible to image noise, and the detection effect is not ideal. Markov Random Field (MRF) can make full use of the spatial dependence of image pixels and improve detection accuracy. When segmenting the difference image, different categories of regions have a high degree of similarity at the junction of them. It is difficult to clearly distinguish the labels of the pixels near the boundaries of the judgment area. In the traditional MRF method, each pixel is given a hard label during iteration. So MRF is a hard decision in the process, and it will cause loss of information. This paper applies the combination of fuzzy theory and MRF to the change detection of SAR images. The experimental results show that the proposed method has better detection effect than the traditional MRF method.
Development of a HIV-1 Virus Detection System Based on Nanotechnology.
Lee, Jin-Ho; Oh, Byung-Keun; Choi, Jeong-Woo
2015-04-27
Development of a sensitive and selective detection system for pathogenic viral agents is essential for medical healthcare from diagnostics to therapeutics. However, conventional detection systems are time consuming, resource-intensive and tedious to perform. Hence, the demand for sensitive and selective detection system for virus are highly increasing. To attain this aim, different aspects and techniques have been applied to develop virus sensor with improved sensitivity and selectivity. Here, among those aspects and techniques, this article reviews HIV virus particle detection systems incorporated with nanotechnology to enhance the sensitivity. This review mainly focused on four different detection system including vertically configured electrical detection based on scanning tunneling microscopy (STM), electrochemical detection based on direct electron transfer in virus, optical detection system based on localized surface plasmon resonance (LSPR) and surface enhanced Raman spectroscopy (SERS) using plasmonic nanoparticle.
Compositions and methods for detecting single nucleotide polymorphisms
Yeh, Hsin-Chih; Werner, James; Martinez, Jennifer S.
2016-11-22
Described herein are nucleic acid based probes and methods for discriminating and detecting single nucleotide variants in nucleic acid molecules (e.g., DNA). The methods include use of a pair of probes can be used to detect and identify polymorphisms, for example single nucleotide polymorphism in DNA. The pair of probes emit a different fluorescent wavelength of light depending on the association and alignment of the probes when hybridized to a target nucleic acid molecule. Each pair of probes is capable of discriminating at least two different nucleic acid molecules that differ by at least a single nucleotide difference. The methods can probes can be used, for example, for detection of DNA polymorphisms that are indicative of a particular disease or condition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, C; Han, M; Baek, J
Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photonsmore » per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR{sup 2} ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201-14-1002) supervised by the NIPA (National IT Industry Promotion Agency). Authors declares that s/he has no conflict of Interest in relation to the work in this abstract.« less
NASA Astrophysics Data System (ADS)
Chang, Faliang; Liu, Chunsheng
2017-09-01
The high variability of sign colors and shapes in uncontrolled environments has made the detection of traffic signs a challenging problem in computer vision. We propose a traffic sign detection (TSD) method based on coarse-to-fine cascade and parallel support vector machine (SVM) detectors to detect Chinese warning and danger traffic signs. First, a region of interest (ROI) extraction method is proposed to extract ROIs using color contrast features in local regions. The ROI extraction can reduce scanning regions and save detection time. For multiclass TSD, we propose a structure that combines a coarse-to-fine cascaded tree with a parallel structure of histogram of oriented gradients (HOG) + SVM detectors. The cascaded tree is designed to detect different types of traffic signs in a coarse-to-fine process. The parallel HOG + SVM detectors are designed to do fine detection of different types of traffic signs. The experiments demonstrate the proposed TSD method can rapidly detect multiclass traffic signs with different colors and shapes in high accuracy.
Stansley, William; Cummings, Margaret; Vudathala, Daljit; Murphy, Lisa A
2014-01-01
Liver samples from red-tailed hawks (Buteo jamaicensis) and great horned owls (Bubo virginianus) were analyzed for anticoagulant rodenticides. Residues of one or more second generation anticoagulant rodenticides (SGARs) were detected in 81 % of red-tailed hawks and 82 % of great horned owls. The most frequently detected SGAR was brodifacoum, which was detected in 76 % of red-tailed hawks and 73 % of great horned owls. Bromadiolone was detected in 20 % of red-tailed hawks and 27 % of great horned owls. Difenacoum was detected in one great horned owl. No other ARs were detected. There were no significant differences between species in the frequency of detection or concentration of brodifacoum or bromadiolone. There was a marginally significant difference (p = 0.0497) between total SGAR residues in red-tailed hawks (0.117 mg/kg) and great horned owls (0.070 mg/kg). There were no seasonal differences in the frequency of detection or concentration of brodifacoum in red-tailed hawks. The data suggest that SGARs pose a significant risk of poisoning to predatory birds in New Jersey.
Infrared small target detection technology based on OpenCV
NASA Astrophysics Data System (ADS)
Liu, Lei; Huang, Zhijian
2013-05-01
Accurate and fast detection of infrared (IR) dim target has very important meaning for infrared precise guidance, early warning, video surveillance, etc. In this paper, some basic principles and the implementing flow charts of a series of algorithms for target detection are described. These algorithms are traditional two-frame difference method, improved three-frame difference method, background estimate and frame difference fusion method, and building background with neighborhood mean method. On the foundation of above works, an infrared target detection software platform which is developed by OpenCV and MFC is introduced. Three kinds of tracking algorithms are integrated in this software. In order to explain the software clearly, the framework and the function are described in this paper. At last, the experiments are performed for some real-life IR images. The whole algorithm implementing processes and results are analyzed, and those algorithms for detection targets are evaluated from the two aspects of subjective and objective. The results prove that the proposed method has satisfying detection effectiveness and robustness. Meanwhile, it has high detection efficiency and can be used for real-time detection.
Infrared small target detection technology based on OpenCV
NASA Astrophysics Data System (ADS)
Liu, Lei; Huang, Zhijian
2013-09-01
Accurate and fast detection of infrared (IR) dim target has very important meaning for infrared precise guidance, early warning, video surveillance, etc. In this paper, some basic principles and the implementing flow charts of a series of algorithms for target detection are described. These algorithms are traditional two-frame difference method, improved three-frame difference method, background estimate and frame difference fusion method, and building background with neighborhood mean method. On the foundation of above works, an infrared target detection software platform which is developed by OpenCV and MFC is introduced. Three kinds of tracking algorithms are integrated in this software. In order to explain the software clearly, the framework and the function are described in this paper. At last, the experiments are performed for some real-life IR images. The whole algorithm implementing processes and results are analyzed, and those algorithms for detection targets are evaluated from the two aspects of subjective and objective. The results prove that the proposed method has satisfying detection effectiveness and robustness. Meanwhile, it has high detection efficiency and can be used for real-time detection.
Engineered nanoconstructs for the multiplexed and sensitive detection of high-risk pathogens
NASA Astrophysics Data System (ADS)
Seo, Youngmin; Kim, Ji-Eun; Jeong, Yoon; Lee, Kwan Hong; Hwang, Jangsun; Hong, Jongwook; Park, Hansoo; Choi, Jonghoon
2016-01-01
Many countries categorize the causative agents of severe infectious diseases as high-risk pathogens. Given their extreme infectivity and potential to be used as biological weapons, a rapid and sensitive method for detection of high-risk pathogens (e.g., Bacillus anthracis, Francisella tularensis, Yersinia pestis, and Vaccinia virus) is highly desirable. Here, we report the construction of a novel detection platform comprising two units: (1) magnetic beads separately conjugated with multiple capturing antibodies against four different high-risk pathogens for simple and rapid isolation, and (2) genetically engineered apoferritin nanoparticles conjugated with multiple quantum dots and detection antibodies against four different high-risk pathogens for signal amplification. For each high-risk pathogen, we demonstrated at least 10-fold increase in sensitivity compared to traditional lateral flow devices that utilize enzyme-based detection methods. Multiplexed detection of high-risk pathogens in a sample was also successful by using the nanoconstructs harboring the dye molecules with fluorescence at different wavelengths. We ultimately envision the use of this novel nanoprobe detection platform in future applications that require highly sensitive on-site detection of high-risk pathogens.
Social Eavesdropping: Can You Hear the Emotionality in a "Hello" That Is Not Meant for You?
Karthikeyan, Sethu; Ramachandra, Vijayachandra
2017-01-01
The study examined third-party listeners' ability to detect the Hellos spoken to prevalidated happy, neutral, and sad facial expressions. The average detection accuracies from the happy and sad (HS), happy and neutral (HN), and sad and neutral (SN) listening tests followed the average vocal pitch differences between the two sets of Hellos in each of the tests; HS and HN detection accuracies were above chance reflecting the significant pitch differences between the respective Hellos. The SN detection accuracy was at chance reflecting the lack of pitch difference between sad and neutral Hellos. As expected, the SN detection accuracy positively correlated with theory of mind; participating in these tests has been likened to the act of eavesdropping, which has been discussed from an evolutionary perspective. An unexpected negative correlation between the HS detection accuracy and the empathy quotient has been discussed with respect to autism research on empathy and pitch discrimination.
Ma, Ying-ying; Zhang, Tao-wen; Jiang, Yu-xi; Liu, Shu-tai
2015-10-01
To detect the existence of Aa,Pg,Tf,Cr,Ec and Pn in the subgingival plaque, and determine their relationships among different types of periodontal diseases. Dental plaques from 120 subjects were sampled, including 40 volunteers with health periodontal status(Group A) , forty patients with dental plaque-induced gingival diseases(Group B) and 40 patients with moderate or severe chronic periodontitis (Group C) . These samples were detected based on bacterial composition using the terminal restriction fragment length polymorphism of 16S rRNA genes by multiple-polymerase chain reaction. The data was analysed with SPSS 13.0 software package for Chi-square test. The detection rate of Pn, Cr and Pg had significant differences between group A and B. The detection rate of Ec, Cr, Pg, Aa and Tf had significant differences between group C and B. The detection rate of Ec, Pn, Cr, Pg, Aa and Tf had significant differences between group A and C. The rate of Ec, Pn, Cr, Pg and Tf detected in moderate or patients with moderate or severe chronic periodontitis are significantly higher than that in healthy subjects, indicating that these bacteria have certain correlation with chronic periodontitis. The rate of Ec, Cr, Pg and Tf detected in severe chronic periodontitis are significantly higher than that in dental-induced gingivitis, suggesting their close relationship with the progress of periodontal disease.
Guided wave and damage detection in composite laminates using different fiber optic sensors.
Li, Fucai; Murayama, Hideaki; Kageyama, Kazuro; Shirai, Takehiro
2009-01-01
Guided wave detection using different fiber optic sensors and their applications in damage detection for composite laminates were systematically investigated and compared in this paper. Two types of fiber optic sensors, namely fiber Bragg gratings (FBG) and Doppler effect-based fiber optic (FOD) sensors, were addressed and guided wave detection systems were constructed for both types. Guided waves generated by a piezoelectric transducer were propagated through a quasi-isotropic carbon fiber reinforced plastic (CFRP) laminate and acquired by these fiber optic sensors. Characteristics of these fiber optic sensors in ultrasonic guided wave detection were systematically compared. Results demonstrated that both the FBG and FOD sensors can be applied in guided wave and damage detection for the CFRP laminates. The signal-to-noise ratio (SNR) of guided wave signal captured by an FOD sensor is relatively high in comparison with that of the FBG sensor because of their different physical principles in ultrasonic detection. Further, the FOD sensor is sensitive to the damage-induced fundamental shear horizontal (SH(0)) guided wave that, however, cannot be detected by using the FBG sensor, because the FOD sensor is omnidirectional in ultrasound detection and, in contrast, the FBG sensor is severely direction dependent.
Harris, Kelly C.; Wilson, Sara; Eckert, Mark A.; Dubno, Judy R.
2011-01-01
Objectives The goal of this study was to examine the degree to which age-related differences in early or automatic levels of auditory processing and attention-related processes explain age-related differences in auditory temporal processing. We hypothesized that age-related differences in attention and cognition compound age-related differences at automatic levels of processing, contributing to the robust age effects observed during challenging listening tasks. Design We examined age-related and individual differences in cortical event-related potential (ERP) amplitudes and latencies, processing speed, and gap detection from twenty-five younger and twenty-five older adults with normal hearing. ERPs were elicited by brief silent periods (gaps) in an otherwise continuous broadband noise and were measured under two listening conditions, passive and active. During passive listening, participants ignored the stimulus and read quietly. During active listening, participants button pressed each time they detected a gap. Gap detection (percent detected) was calculated for each gap duration during active listening (3, 6, 9, 12 and 15 ms). Processing speed was assessed using the Purdue Pegboard test and the Connections Test. Repeated measures ANOVAs assessed effects of age on gap detection, processing speed, and ERP amplitudes and latencies. An “attention modulation” construct was created using linear regression to examine the effects of attention while controlling for age-related differences in auditory processing. Pearson correlation analyses assessed the extent to which attention modulation, ERPs, and processing speed predicted behavioral gap detection. Results: Older adults had significantly poorer gap detection and slower processing speed than younger adults. Even after adjusting for poorer gap detection, the neurophysiological response to gap onset was atypical in older adults with reduced P2 amplitudes and virtually absent N2 responses. Moreover, individual differences in attention modulation of P2 response latencies and N2 amplitudes predicted gap detection and processing speed in older adults. That is, older adults with P2 latencies that decreased and N2 amplitudes that increased with active listening had faster processing speed and better gap detection than those older adults whose P2 latencies increased and N2 amplitudes decreased with attention Conclusions Results from the current study are broadly consistent with previous findings that older adults exhibit significantly poorer gap detection than younger adults in challenging tasks. Even after adjusting for poorer gap detection, older and younger adults showed robust differences in their electrophysiological responses to sound offset. Furthermore, the degree to which attention modulated the ERP was associated with individual variation in measures of processing speed and gap detection. Taken together, these results suggests an age-related deficit in early or automatic levels of auditory temporal processing and that some older adults may be less able to compensate for declines in processing by attending to the stimulus. These results extend our previous findings and support the hypothesis that age-related differences in cognitive or attention-related processing, including processing speed, contribute to an age-related decrease in gap detection. PMID:22374321
Decisions that Make a Difference in Detecting Differential Item Functioning
ERIC Educational Resources Information Center
Sireci, Stephen G.; Rios, Joseph A.
2013-01-01
There are numerous statistical procedures for detecting items that function differently across subgroups of examinees that take a test or survey. However, in endeavouring to detect items that may function differentially, selection of the statistical method is only one of many important decisions. In this article, we discuss the important decisions…
USDA-ARS?s Scientific Manuscript database
Molecular detection of bacterial pathogens based on LAMP methods is a faster and simpler approach than conventional culture methods. Although different LAMP-based methods for pathogenic bacterial detection are available, a systematic comparison of these different LAMP assays has not been performed. ...
Feature Sampling in Detection: Implications for the Measurement of Perceptual Independence
ERIC Educational Resources Information Center
Macho, Siegfried
2007-01-01
The article presents the feature sampling signal detection (FS-SDT) model, an extension of the multivariate signal detection (SDT) model. The FS-SDT model assumes that, because of attentional shifts, different subsets of features are sampled for different presentations of the same multidimensional stimulus. Contrary to the SDT model, the FS-SDT…
The Comparison of Visual Working Memory Representations with Perceptual Inputs
Hyun, Joo-seok; Woodman, Geoffrey F.; Vogel, Edward K.; Hollingworth, Andrew
2008-01-01
The human visual system can notice differences between memories of previous visual inputs and perceptions of new visual inputs, but the comparison process that detects these differences has not been well characterized. This study tests the hypothesis that differences between the memory of a stimulus array and the perception of a new array are detected in a manner that is analogous to the detection of simple features in visual search tasks. That is, just as the presence of a task-relevant feature in visual search can be detected in parallel, triggering a rapid shift of attention to the object containing the feature, the presence of a memory-percept difference along a task-relevant dimension can be detected in parallel, triggering a rapid shift of attention to the changed object. Supporting evidence was obtained in a series of experiments that examined manual reaction times, saccadic reaction times, and event-related potential latencies. However, these experiments also demonstrated that a slow, limited-capacity process must occur before the observer can make a manual change-detection response. PMID:19653755
de Souza, Marjorie M A; Hartel, Gunter; Whiteman, David C; Antonsson, Annika
2018-04-01
Very little is known about the natural history of oral HPV infection. Several different methods exist to collect oral specimens and detect HPV, but their respective performance characteristics are unknown. We compared two different methods for oral specimen collection (oral saline rinse and commercial saliva kit) from 96 individuals and then analyzed the samples for HPV by two different PCR detection methods (single GP5+/6+ PCR and nested MY09/11 and GP5+/6+ PCR). For the oral rinse samples, the oral HPV prevalence was 10.4% (GP+ PCR; 10% repeatability) vs 11.5% (nested PCR method; 100% repeatability). For the commercial saliva kit samples, the prevalences were 3.1% vs 16.7% with the GP+ PCR vs the nested PCR method (repeatability 100% for both detection methods). Overall the agreement was fair or poor between samples and methods (kappa 0.06-0.36). Standardizing methods of oral sample collection and HPV detection would ensure comparability between future oral HPV studies. Copyright © 2017 Elsevier Inc. All rights reserved.
Law, Marvin K H; Jackson, Simon A; Aidman, Eugene; Geiger, Mattis; Olderbak, Sally; Kleitman, Sabina
2018-01-01
Individual differences in lie detection remain poorly understood. Bond and DePaulo's meta-analysis examined judges (receivers) who were ascertaining lies from truths and senders (deceiver) who told these lies and truths. Bond and DePaulo found that the accuracy of detecting deception depended more on the characteristics of senders rather than the judges' ability to detect lies/truths. However, for many studies in this meta-analysis, judges could hear and understand senders. This made language comprehension a potential confound. This paper presents the results of two studies. Extending previous work, in Study 1, we removed language comprehension as a potential confound by having English-speakers (N = 126, mean age = 19.86) judge the veracity of German speakers (n = 12) in a lie detection task. The twelve lie-detection stimuli included emotional and non-emotional content, and were presented in three modalities-audio only, video only, and audio and video together. The intelligence (General, Auditory, Emotional) and personality (Dark Triads and Big 6) of participants was also assessed. In Study 2, a native German-speaking sample (N = 117, mean age = 29.10) were also tested on a similar lie detection task to provide a control condition. Despite significantly extending research design and the selection of constructs employed to capture individual differences, both studies replicated Bond and DePaulo's findings. The results of Study1 indicated that removing language comprehension did not amplify individual differences in judge's ability to ascertain lies from truths. Study 2 replicated these results confirming a lack of individual differences in judge's ability to detect lies. The results of both studies suggest that Sender (deceiver) characteristics exerted a stronger influence on the outcomes of lie detection than the judge's attributes.
O'Connell, Allan F.; Talancy, Neil W.; Bailey, Larissa L.; Sauer, John R.; Cook, Robert; Gilbert, Andrew T.
2006-01-01
Large-scale, multispecies monitoring programs are widely used to assess changes in wildlife populations but they often assume constant detectability when documenting species occurrence. This assumption is rarely met in practice because animal populations vary across time and space. As a result, detectability of a species can be influenced by a number of physical, biological, or anthropogenic factors (e.g., weather, seasonality, topography, biological rhythms, sampling methods). To evaluate some of these influences, we estimated site occupancy rates using species-specific detection probabilities for meso- and large terrestrial mammal species on Cape Cod, Massachusetts, USA. We used model selection to assess the influence of different sampling methods and major environmental factors on our ability to detect individual species. Remote cameras detected the most species (9), followed by cubby boxes (7) and hair traps (4) over a 13-month period. Estimated site occupancy rates were similar among sampling methods for most species when detection probabilities exceeded 0.15, but we question estimates obtained from methods with detection probabilities between 0.05 and 0.15, and we consider methods with lower probabilities unacceptable for occupancy estimation and inference. Estimated detection probabilities can be used to accommodate variation in sampling methods, which allows for comparison of monitoring programs using different protocols. Vegetation and seasonality produced species-specific differences in detectability and occupancy, but differences were not consistent within or among species, which suggests that our results should be considered in the context of local habitat features and life history traits for the target species. We believe that site occupancy is a useful state variable and suggest that monitoring programs for mammals using occupancy data consider detectability prior to making inferences about species distributions or population change.
A Comparative Analysis of Pitch Detection Methods Under the Influence of Different Noise Conditions.
Sukhostat, Lyudmila; Imamverdiyev, Yadigar
2015-07-01
Pitch is one of the most important components in various speech processing systems. The aim of this study was to evaluate different pitch detection methods in terms of various noise conditions. Prospective study. For evaluation of pitch detection algorithms, time-domain, frequency-domain, and hybrid methods were considered by using Keele and CSTR speech databases. Each of them has its own advantages and disadvantages. Experiments have shown that BaNa method achieves the highest pitch detection accuracy. The development of methods for pitch detection, which are robust to additive noise at different signal-to-noise ratio, is an important field of research with many opportunities for enhancement the modern methods. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Shape detection of Gaborized outline versions of everyday objects
Sassi, Michaël; Machilsen, Bart; Wagemans, Johan
2012-01-01
We previously tested the identifiability of six versions of Gaborized outlines of everyday objects, differing in the orientations assigned to elements inside and outside the outline. We found significant differences in identifiability between the versions, and related a number of stimulus metrics to identifiability [Sassi, M., Vancleef, K., Machilsen, B., Panis, S., & Wagemans, J. (2010). Identification of everyday objects on the basis of Gaborized outline versions. i-Perception, 1(3), 121–142]. In this study, after retesting the identifiability of new variants of three of the stimulus versions, we tested their robustness to local orientation jitter in a detection experiment. In general, our results replicated the key findings from the previous study, and allowed us to substantiate our earlier interpretations of the effects of our stimulus metrics and of the performance differences between the different stimulus versions. The results of the detection task revealed a different ranking order of stimulus versions than the identification task. By examining the parallels and differences between the effects of our stimulus metrics in the two tasks, we found evidence for a trade-off between shape detectability and identifiability. The generally simple and smooth shapes that yield the strongest contour integration and most robust detectability tend to lack the distinguishing features necessary for clear-cut identification. Conversely, contours that do contain such identifying features tend to be inherently more complex and, therefore, yield weaker integration and less robust detectability. PMID:23483752
Evaluating Bayesian Networks' Precision for Detecting Students' Learning Styles
ERIC Educational Resources Information Center
Garcia, Patricio; Amandi, Analia; Schiaffino, Silvia; Campo, Marcelo
2007-01-01
Students are characterized by different learning styles, focusing on different types of information and processing this information in different ways. One of the desirable characteristics of a Web-based education system is that all the students can learn despite their different learning styles. To achieve this goal we have to detect how students…
A framework for detecting communities of unbalanced sizes in networks
NASA Astrophysics Data System (ADS)
Žalik, Krista Rizman; Žalik, Borut
2018-01-01
Community detection in large networks has been a focus of recent research in many of fields, including biology, physics, social sciences, and computer science. Most community detection methods partition the entire network into communities, groups of nodes that have many connections within communities and few connections between them and do not identify different roles that nodes can have in communities. We propose a community detection model that integrates more different measures that can fast identify communities of different sizes and densities. We use node degree centrality, strong similarity with one node from community, maximal similarity of node to community, compactness of communities and separation between communities. Each measure has its own strength and weakness. Thus, combining different measures can benefit from the strengths of each one and eliminate encountered problems of using an individual measure. We present a fast local expansion algorithm for uncovering communities of different sizes and densities and reveals rich information on input networks. Experimental results show that the proposed algorithm is better or as effective as the other community detection algorithms for both real-world and synthetic networks while it requires less time.
NASA Astrophysics Data System (ADS)
Morphew, Jason W.; Mestre, Jose P.; Ross, Brian H.; Strand, Natalie E.
2015-12-01
It is known that experts identify or perceive meaningful patterns in visual stimuli related to their domain of expertise. This study explores the speed with which experts and novices detect changes in physics diagrams. Since change detection depends on where individuals direct their attention, differences in the speed with which experts and novices detect changes to diagrams would suggest differences in attention allocation between experts and novices. We present data from an experiment using the "flicker technique," in which both physics experts and physics novices viewed nearly identical pairs of diagrams that are representative of typical introductory physics situations. The two diagrams in each pair contain a subtle difference that either does or does not change the underlying physics depicted in the diagram. Findings indicate that experts are faster at detecting physics-relevant changes than physics-irrelevant changes; however, there is no difference in response time for novices, suggesting that expertise guides attention for experts when inspecting physics diagrams. We discuss the cognitive implications of our findings.
Change detection in satellite images
NASA Astrophysics Data System (ADS)
Thonnessen, U.; Hofele, G.; Middelmann, W.
2005-05-01
Change detection plays an important role in different military areas as strategic reconnaissance, verification of armament and disarmament control and damage assessment. It is the process of identifying differences in the state of an object or phenomenon by observing it at different times. The availability of spaceborne reconnaissance systems with high spatial resolution, multi spectral capabilities, and short revisit times offer new perspectives for change detection. Before performing any kind of change detection it is necessary to separate changes of interest from changes caused by differences in data acquisition parameters. In these cases it is necessary to perform a pre-processing to correct the data or to normalize it. Image registration and, corresponding to this task, the ortho-rectification of the image data is a further prerequisite for change detection. If feasible, a 1-to-1 geometric correspondence should be aspired for. Change detection on an iconic level with a succeeding interpretation of the changes by the observer is often proposed; nevertheless an automatic knowledge-based analysis delivering the interpretation of the changes on a semantic level should be the aim of the future. We present first results of change detection on a structural level concerning urban areas. After pre-processing, the images are segmented in areas of interest and structural analysis is applied to these regions to extract descriptions of urban infrastructure like buildings, roads and tanks of refineries. These descriptions are matched to detect changes and similarities.
Sensors and Clinical Mastitis—The Quest for the Perfect Alert
Hogeveen, Henk; Kamphuis, Claudia; Steeneveld, Wilma; Mollenhorst, Herman
2010-01-01
When cows on dairy farms are milked with an automatic milking system or in high capacity milking parlors, clinical mastitis (CM) cannot be adequately detected without sensors. The objective of this paper is to describe the performance demands of sensor systems to detect CM and evaluats the current performance of these sensor systems. Several detection models based on different sensors were studied in the past. When evaluating these models, three factors are important: performance (in terms of sensitivity and specificity), the time window and the similarity of the study data with real farm data. A CM detection system should offer at least a sensitivity of 80% and a specificity of 99%. The time window should not be longer than 48 hours and study circumstances should be as similar to practical farm circumstances as possible. The study design should comprise more than one farm for data collection. Since 1992, 16 peer-reviewed papers have been published with a description and evaluation of CM detection models. There is a large variation in the use of sensors and algorithms. All this makes these results not very comparable. There is a also large difference in performance between the detection models and also a large variation in time windows used and little similarity between study data. Therefore, it is difficult to compare the overall performance of the different CM detection models. The sensitivity and specificity found in the different studies could, for a large part, be explained in differences in the used time window. None of the described studies satisfied the demands for CM detection models. PMID:22163637
Sensors and clinical mastitis--the quest for the perfect alert.
Hogeveen, Henk; Kamphuis, Claudia; Steeneveld, Wilma; Mollenhorst, Herman
2010-01-01
When cows on dairy farms are milked with an automatic milking system or in high capacity milking parlors, clinical mastitis (CM) cannot be adequately detected without sensors. The objective of this paper is to describe the performance demands of sensor systems to detect CM and evaluats the current performance of these sensor systems. Several detection models based on different sensors were studied in the past. When evaluating these models, three factors are important: performance (in terms of sensitivity and specificity), the time window and the similarity of the study data with real farm data. A CM detection system should offer at least a sensitivity of 80% and a specificity of 99%. The time window should not be longer than 48 hours and study circumstances should be as similar to practical farm circumstances as possible. The study design should comprise more than one farm for data collection. Since 1992, 16 peer-reviewed papers have been published with a description and evaluation of CM detection models. There is a large variation in the use of sensors and algorithms. All this makes these results not very comparable. There is a also large difference in performance between the detection models and also a large variation in time windows used and little similarity between study data. Therefore, it is difficult to compare the overall performance of the different CM detection models. The sensitivity and specificity found in the different studies could, for a large part, be explained in differences in the used time window. None of the described studies satisfied the demands for CM detection models.
A Dual Frequency Carrier Phase Error Difference Checking Algorithm for the GNSS Compass.
Liu, Shuo; Zhang, Lei; Li, Jian
2016-11-24
The performance of the Global Navigation Satellite System (GNSS) compass is related to the quality of carrier phase measurement. How to process the carrier phase error properly is important to improve the GNSS compass accuracy. In this work, we propose a dual frequency carrier phase error difference checking algorithm for the GNSS compass. The algorithm aims at eliminating large carrier phase error in dual frequency double differenced carrier phase measurement according to the error difference between two frequencies. The advantage of the proposed algorithm is that it does not need additional environment information and has a good performance on multiple large errors compared with previous research. The core of the proposed algorithm is removing the geographical distance from the dual frequency carrier phase measurement, then the carrier phase error is separated and detectable. We generate the Double Differenced Geometry-Free (DDGF) measurement according to the characteristic that the different frequency carrier phase measurements contain the same geometrical distance. Then, we propose the DDGF detection to detect the large carrier phase error difference between two frequencies. The theoretical performance of the proposed DDGF detection is analyzed. An open sky test, a manmade multipath test and an urban vehicle test were carried out to evaluate the performance of the proposed algorithm. The result shows that the proposed DDGF detection is able to detect large error in dual frequency carrier phase measurement by checking the error difference between two frequencies. After the DDGF detection, the accuracy of the baseline vector is improved in the GNSS compass.
Using CdTe/ZnSe core/shell quantum dots to detect DNA and damage to DNA
Moulick, Amitava; Milosavljevic, Vedran; Vlachova, Jana; Podgajny, Robert; Hynek, David; Kopel, Pavel; Adam, Vojtech
2017-01-01
CdTe/ZnSe core/shell quantum dot (QD), one of the strongest and most highly luminescent nanoparticles, was directly synthesized in an aqueous medium to study its individual interactions with important nucleobases (adenine, guanine, cytosine, and thymine) in detail. The results obtained from the optical analyses indicated that the interactions of the QDs with different nucleobases were different, which reflected in different fluorescent emission maxima and intensities. The difference in the interaction was found due to the different chemical behavior and different sizes of the formed nanoconjugates. An electrochemical study also confirmed that the purines and pyrimidines show different interactions with the core/shell QDs. Based on these phenomena, a novel QD-based method is developed to detect the presence of the DNA, damage to DNA, and mutation. The QDs were successfully applied very easily to detect any change in the sequence (mutation) of DNA. The QDs also showed their ability to detect DNAs directly from the extracts of human cancer (PC3) and normal (PNT1A) cells (detection limit of 500 pM of DNA), which indicates the possibilities to use this easy assay technique to confirm the presence of living organisms in extreme environments. PMID:28243089
NASA Astrophysics Data System (ADS)
Krauß, T.
2014-11-01
The focal plane assembly of most pushbroom scanner satellites is built up in a way that different multispectral or multispectral and panchromatic bands are not all acquired exactly at the same time. This effect is due to offsets of some millimeters of the CCD-lines in the focal plane. Exploiting this special configuration allows the detection of objects moving during this small time span. In this paper we present a method for automatic detection and extraction of moving objects - mainly traffic - from single very high resolution optical satellite imagery of different sensors. The sensors investigated are WorldView-2, RapidEye, Pléiades and also the new SkyBox satellites. Different sensors require different approaches for detecting moving objects. Since the objects are mapped on different positions only in different spectral bands also the change of spectral properties have to be taken into account. In case the main distance in the focal plane is between the multispectral and the panchromatic CCD-line like for Pléiades an approach for weighted integration to receive mostly identical images is investigated. Other approaches for RapidEye and WorldView-2 are also shown. From these intermediate bands difference images are calculated and a method for detecting the moving objects from these difference images is proposed. Based on these presented methods images from different sensors are processed and the results are assessed for detection quality - how many moving objects can be detected, how many are missed - and accuracy - how accurate is the derived speed and size of the objects. Finally the results are discussed and an outlook for possible improvements towards operational processing is presented.
Inferences about landbird abundance from count data: recent advances and future directions
Nichols, J.D.; Thomas, L.; Conn, P.B.; Thomson, David L.; Cooch, Evan G.; Conroy, Michael J.
2009-01-01
We summarize results of a November 2006 workshop dealing with recent research on the estimation of landbird abundance from count data. Our conceptual framework includes a decomposition of the probability of detecting a bird potentially exposed to sampling efforts into four separate probabilities. Primary inference methods are described and include distance sampling, multiple observers, time of detection, and repeated counts. The detection parameters estimated by these different approaches differ, leading to different interpretations of resulting estimates of density and abundance. Simultaneous use of combinations of these different inference approaches can not only lead to increased precision but also provides the ability to decompose components of the detection process. Recent efforts to test the efficacy of these different approaches using natural systems and a new bird radio test system provide sobering conclusions about the ability of observers to detect and localize birds in auditory surveys. Recent research is reported on efforts to deal with such potential sources of error as bird misclassification, measurement error, and density gradients. Methods for inference about spatial and temporal variation in avian abundance are outlined. Discussion topics include opinions about the need to estimate detection probability when drawing inference about avian abundance, methodological recommendations based on the current state of knowledge and suggestions for future research.
Cho, Sun-Joo; Preacher, Kristopher J.; Bottge, Brian A.
2015-01-01
Multilevel modeling (MLM) is frequently used to detect group differences, such as an intervention effect in a pre-test–post-test cluster-randomized design. Group differences on the post-test scores are detected by controlling for pre-test scores as a proxy variable for unobserved factors that predict future attributes. The pre-test and post-test scores that are most often used in MLM are summed item responses (or total scores). In prior research, there have been concerns regarding measurement error in the use of total scores in using MLM. To correct for measurement error in the covariate and outcome, a theoretical justification for the use of multilevel structural equation modeling (MSEM) has been established. However, MSEM for binary responses has not been widely applied to detect intervention effects (group differences) in intervention studies. In this article, the use of MSEM for intervention studies is demonstrated and the performance of MSEM is evaluated via a simulation study. Furthermore, the consequences of using MLM instead of MSEM are shown in detecting group differences. Results of the simulation study showed that MSEM performed adequately as the number of clusters, cluster size, and intraclass correlation increased and outperformed MLM for the detection of group differences. PMID:29881032
Cho, Sun-Joo; Preacher, Kristopher J; Bottge, Brian A
2015-11-01
Multilevel modeling (MLM) is frequently used to detect group differences, such as an intervention effect in a pre-test-post-test cluster-randomized design. Group differences on the post-test scores are detected by controlling for pre-test scores as a proxy variable for unobserved factors that predict future attributes. The pre-test and post-test scores that are most often used in MLM are summed item responses (or total scores). In prior research, there have been concerns regarding measurement error in the use of total scores in using MLM. To correct for measurement error in the covariate and outcome, a theoretical justification for the use of multilevel structural equation modeling (MSEM) has been established. However, MSEM for binary responses has not been widely applied to detect intervention effects (group differences) in intervention studies. In this article, the use of MSEM for intervention studies is demonstrated and the performance of MSEM is evaluated via a simulation study. Furthermore, the consequences of using MLM instead of MSEM are shown in detecting group differences. Results of the simulation study showed that MSEM performed adequately as the number of clusters, cluster size, and intraclass correlation increased and outperformed MLM for the detection of group differences.
A Multicenter Study To Evaluate the Performance of High-Throughput Sequencing for Virus Detection
Ng, Siemon H. S.; Vandeputte, Olivier; Aljanahi, Aisha; Deyati, Avisek; Cassart, Jean-Pol; Charlebois, Robert L.; Taliaferro, Lanyn P.
2017-01-01
ABSTRACT The capability of high-throughput sequencing (HTS) for detection of known and unknown viruses makes it a powerful tool for broad microbial investigations, such as evaluation of novel cell substrates that may be used for the development of new biological products. However, like any new assay, regulatory applications of HTS need method standardization. Therefore, our three laboratories initiated a study to evaluate performance of HTS for potential detection of viral adventitious agents by spiking model viruses in different cellular matrices to mimic putative materials for manufacturing of biologics. Four model viruses were selected based upon different physical and biochemical properties and commercial availability: human respiratory syncytial virus (RSV), Epstein-Barr virus (EBV), feline leukemia virus (FeLV), and human reovirus (REO). Additionally, porcine circovirus (PCV) was tested by one laboratory. Independent samples were prepared for HTS by spiking intact viruses or extracted viral nucleic acids, singly or mixed, into different HeLa cell matrices (resuspended whole cells, cell lysate, or total cellular RNA). Data were obtained using different sequencing platforms (Roche 454, Illumina HiSeq1500 or HiSeq2500). Bioinformatic analyses were performed independently by each laboratory using available tools, pipelines, and databases. The results showed that comparable virus detection was obtained in the three laboratories regardless of sample processing, library preparation, sequencing platform, and bioinformatic analysis: between 0.1 and 3 viral genome copies per cell were detected for all of the model viruses used. This study highlights the potential for using HTS for sensitive detection of adventitious viruses in complex biological samples containing cellular background. IMPORTANCE Recent high-throughput sequencing (HTS) investigations have resulted in unexpected discoveries of known and novel viruses in a variety of sample types, including research materials, clinical materials, and biological products. Therefore, HTS can be a powerful tool for supplementing current methods for demonstrating the absence of adventitious or unwanted viruses in biological products, particularly when using a new cell line. However, HTS is a complex technology with different platforms, which needs standardization for evaluation of biologics. This collaborative study was undertaken to investigate detection of different virus types using two different HTS platforms. The results of the independently performed studies demonstrated a similar sensitivity of virus detection, regardless of the different sample preparation and processing procedures and bioinformatic analyses done in the three laboratories. Comparable HTS detection of different virus types supports future development of reference virus materials for standardization and validation of different HTS platforms. PMID:28932815
Updating Landsat-derived land-cover maps using change detection and masking techniques
NASA Technical Reports Server (NTRS)
Likens, W.; Maw, K.
1982-01-01
The California Integrated Remote Sensing System's San Bernardino County Project was devised to study the utilization of a data base at a number of jurisdictional levels. The present paper discusses the implementation of change-detection and masking techniques in the updating of Landsat-derived land-cover maps. A baseline landcover classification was first created from a 1976 image, then the adjusted 1976 image was compared with a 1979 scene by the techniques of (1) multidate image classification, (2) difference image-distribution tails thresholding, (3) difference image classification, and (4) multi-dimensional chi-square analysis of a difference image. The union of the results of methods 1, 3 and 4 was used to create a mask of possible change areas between 1976 and 1979, which served to limit analysis of the update image and reduce comparison errors in unchanged areas. The techniques of spatial smoothing of change-detection products, and of combining results of difference change-detection algorithms are also shown to improve Landsat change-detection accuracies.
Sensor for detecting changes in magnetic fields
Praeg, Walter F.
1981-01-01
A sensor for detecting changes in the magnetic field of the equilibrium-field coil of a Tokamak plasma device comprises a pair of bifilar wires disposed circumferentially, one inside and one outside the equilibrium-field coil. Each is shorted at one end. The difference between the voltages detected at the other ends of the bifilar wires provides a measure of changing flux in the equilibrium-field coil. This difference can be used to detect faults in the coil in time to take action to protect the coil.
Tahirbegi, Islam Bogachan; Ehgartner, Josef; Sulzer, Philipp; Zieger, Silvia; Kasjanow, Alice; Paradiso, Mirco; Strobl, Martin; Bouwes, Dominique; Mayr, Torsten
2017-02-15
The necessities of developing fast, portable, cheap and easy to handle pesticide detection platforms are getting attention of scientific and industrial communities. Although there are some approaches to develop microchip based pesticide detection platforms, there is no compact microfluidic device for the complementary, fast, cheap, reusable and reliable analysis of different pesticides. In this work, a microfluidic device is developed for in-situ analysis of pesticide concentration detected via metabolism/photosynthesis of Chlamydomonas reinhardtii algal cells (algae) in tap water. Algae are grown in glass based microfluidic chip, which contains integrated optical pH and oxygen sensors in a portable system for on-site detection. In addition, intrinsic algal fluorescence is detected to analyze the pesticide concentration in parallel to pH and oxygen sensors with integrated fluorescence detectors. The response of the algae under the effect of different concentrations of pesticides is evaluated and complementary inhibition effects depending on the pesticide concentration are demonstrated. The three different sensors allow the determination of various pesticide concentrations in the nanomolar concentration range. The miniaturized system provides the fast quantification of pesticides in less than 10min and enables the study of toxic effects of different pesticides on Chlamydomonas reinhardtii green algae. Consequently, the microfluidic device described here provides fast and complementary detection of different pesticides with algae in a novel glass based microfluidic device with integrated optical pH, oxygen sensors and algal fluorescence. Copyright © 2016 Elsevier B.V. All rights reserved.
Multiview road sign detection via self-adaptive color model and shape context matching
NASA Astrophysics Data System (ADS)
Liu, Chunsheng; Chang, Faliang; Liu, Chengyun
2016-09-01
The multiview appearance of road signs in uncontrolled environments has made the detection of road signs a challenging problem in computer vision. We propose a road sign detection method to detect multiview road signs. This method is based on several algorithms, including the classical cascaded detector, the self-adaptive weighted Gaussian color model (SW-Gaussian model), and a shape context matching method. The classical cascaded detector is used to detect the frontal road signs in video sequences and obtain the parameters for the SW-Gaussian model. The proposed SW-Gaussian model combines the two-dimensional Gaussian model and the normalized red channel together, which can largely enhance the contrast between the red signs and background. The proposed shape context matching method can match shapes with big noise, which is utilized to detect road signs in different directions. The experimental results show that compared with previous detection methods, the proposed multiview detection method can reach higher detection rate in detecting signs with different directions.
An Adaptive Ship Detection Scheme for Spaceborne SAR Imagery
Leng, Xiangguang; Ji, Kefeng; Zhou, Shilin; Xing, Xiangwei; Zou, Huanxin
2016-01-01
With the rapid development of spaceborne synthetic aperture radar (SAR) and the increasing need of ship detection, research on adaptive ship detection in spaceborne SAR imagery is of great importance. Focusing on practical problems of ship detection, this paper presents a highly adaptive ship detection scheme for spaceborne SAR imagery. It is able to process a wide range of sensors, imaging modes and resolutions. Two main stages are identified in this paper, namely: ship candidate detection and ship discrimination. Firstly, this paper proposes an adaptive land masking method using ship size and pixel size. Secondly, taking into account the imaging mode, incidence angle, and polarization channel of SAR imagery, it implements adaptive ship candidate detection in spaceborne SAR imagery by applying different strategies to different resolution SAR images. Finally, aiming at different types of typical false alarms, this paper proposes a comprehensive ship discrimination method in spaceborne SAR imagery based on confidence level and complexity analysis. Experimental results based on RADARSAT-1, RADARSAT-2, TerraSAR-X, RS-1, and RS-3 images demonstrate that the adaptive scheme proposed in this paper is able to detect ship targets in a fast, efficient and robust way. PMID:27563902
Akram, Usman M; Khan, Shoab A
2012-10-01
There is an ever-increasing interest in the development of automatic medical diagnosis systems due to the advancement in computing technology and also to improve the service by medical community. The knowledge about health and disease is required for reliable and accurate medical diagnosis. Diabetic Retinopathy (DR) is one of the most common causes of blindness and it can be prevented if detected and treated early. DR has different signs and the most distinctive are microaneurysm and haemorrhage which are dark lesions and hard exudates and cotton wool spots which are bright lesions. Location and structure of blood vessels and optic disk play important role in accurate detection and classification of dark and bright lesions for early detection of DR. In this article, we propose a computer aided system for the early detection of DR. The article presents algorithms for retinal image preprocessing, blood vessel enhancement and segmentation and optic disk localization and detection which eventually lead to detection of different DR lesions using proposed hybrid fuzzy classifier. The developed methods are tested on four different publicly available databases. The presented methods are compared with recently published methods and the results show that presented methods outperform all others.
Dissociable Roles of Different Types of Working Memory Load in Visual Detection
Konstantinou, Nikos; Lavie, Nilli
2013-01-01
We contrasted the effects of different types of working memory (WM) load on detection. Considering the sensory-recruitment hypothesis of visual short-term memory (VSTM) within load theory (e.g., Lavie, 2010) led us to predict that VSTM load would reduce visual-representation capacity, thus leading to reduced detection sensitivity during maintenance, whereas load on WM cognitive control processes would reduce priority-based control, thus leading to enhanced detection sensitivity for a low-priority stimulus. During the retention interval of a WM task, participants performed a visual-search task while also asked to detect a masked stimulus in the periphery. Loading WM cognitive control processes (with the demand to maintain a random digit order [vs. fixed in conditions of low load]) led to enhanced detection sensitivity. In contrast, loading VSTM (with the demand to maintain the color and positions of six squares [vs. one in conditions of low load]) reduced detection sensitivity, an effect comparable with that found for manipulating perceptual load in the search task. The results confirmed our predictions and established a new functional dissociation between the roles of different types of WM load in the fundamental visual perception process of detection. PMID:23713796
Fire flame detection based on GICA and target tracking
NASA Astrophysics Data System (ADS)
Rong, Jianzhong; Zhou, Dechuang; Yao, Wei; Gao, Wei; Chen, Juan; Wang, Jian
2013-04-01
To improve the video fire detection rate, a robust fire detection algorithm based on the color, motion and pattern characteristics of fire targets was proposed, which proved a satisfactory fire detection rate for different fire scenes. In this fire detection algorithm: (a) a rule-based generic color model was developed based on analysis on a large quantity of flame pixels; (b) from the traditional GICA (Geometrical Independent Component Analysis) model, a Cumulative Geometrical Independent Component Analysis (C-GICA) model was developed for motion detection without static background and (c) a BP neural network fire recognition model based on multi-features of the fire pattern was developed. Fire detection tests on benchmark fire video clips of different scenes have shown the robustness, accuracy and fast-response of the algorithm.
Dispersive detection of radio-frequency-dressed states
NASA Astrophysics Data System (ADS)
Jammi, Sindhu; Pyragius, Tadas; Bason, Mark G.; Florez, Hans Marin; Fernholz, Thomas
2018-04-01
We introduce a method to dispersively detect alkali-metal atoms in radio-frequency-dressed states. In particular, we use dressed detection to measure populations and population differences of atoms prepared in their clock states. Linear birefringence of the atomic medium enables atom number detection via polarization homodyning, a form of common path interferometry. In order to achieve low technical noise levels, we perform optical sideband detection after adiabatic transformation of bare states into dressed states. The balanced homodyne signal then oscillates independently of field fluctuations at twice the dressing frequency, thus allowing for robust, phase-locked detection that circumvents low-frequency noise. Using probe pulses of two optical frequencies, we can detect both clock states simultaneously and obtain population difference as well as the total atom number. The scheme also allows for difference measurements by direct subtraction of the homodyne signals at the balanced detector, which should technically enable quantum noise limited measurements with prospects for the preparation of spin squeezed states. The method extends to other Zeeman sublevels and can be employed in a range of atomic clock schemes, atom interferometers, and other experiments using dressed atoms.
The use of interaural parameters during incoherence detection in reproducible noise
NASA Astrophysics Data System (ADS)
Goupell, Matthew Joseph
Interaural incoherence is a measure of the dissimilarity of the signals in the left and right ears. It is important in a number of acoustical phenomenon such as a listener's sensation envelopment and apparent source width in room acoustics, speech intelligibility, and binaural release from energetic masking. Humans are incredibly sensitive to the difference between perfectly coherent and slightly incoherent signals, however the nature of this sensitivity is not well understood. The purpose of this dissertation is to understand what parameters are important to incoherence detection. Incoherence is perceived to have time-varying characteristics. It is conjectured that incoherence detection is performed by a process that takes this time dependency into account. Left-ear-right-ear noise-pairs were generated, all with a fixed value of interaural coherence, 0.9922. The noises had a center frequency of 500 Hz, a bandwidth of 14 Hz, and a duration of 500 ms. Listeners were required to discriminate between these slightly incoherent noises and diotic noises, with a coherence of 1.0. It was found that the value of interaural incoherence itself was an inadequate predictor of discrimination. Instead, incoherence was much more readily detected for those noise-pairs with the largest fluctuations in interaural phase and level differences (as measured by the standard deviation). Noise-pairs with the same value of coherence, and geometric mean frequency of 500 Hz were also generated for bandwidths of 108 Hz and 2394 Hz. It was found that for increasing bandwidth, fluctuations in interaural differences varied less between different noise-pairs and that detection performance varied less as well. The results suggest that incoherence detection is based on the size and the speed of interaural fluctuations and that the value of coherence itself predicts performance only in the wide-band limit where different particular noises with the same incoherence have similar fluctuations. Noise-pairs with short durations of 100, 50, and 25 ms, and bandwidth of 14 Hz, and a coherence of 0.9922 were used to test if a short-term incoherence function is used in incoherence detection. It was found that listeners could significantly use fluctuations of phase and level to detect incoherence for all three of these short durations. Therefore, a short-term coherence function is not used to detect incoherence. For the smallest duration of 25 ms, listeners' detection cue sometimes changed from a "width" cue to a lateralization cue. Modeling of the data was performed. Ten different binaural models were tested against detection data for 14-Hz and 108-Hz bandwidths. These models included different types of binaural processing: independent interaural phase and level differences, lateral position, and short-term cross-correlation. Several preprocessing features were incorporated in the models: compression, temporal averaging, and envelope weighting. For the 14-Hz bandwidth data, the most successful model assumed independent centers for interaural phase and interaural level processing, and this model correlated with detectability at r = 0.87. That model also described the data best when it was assumed that interaural phase fluctuations and interaural level fluctuations contribute approximately equally to incoherence detection. For the 108-Hz bandwidth data, detection performance varied much less among different waveforms, and the data were less able to distinguish between models.
A Multi-Scale Algorithm for Graffito Advertisement Detection from Images of Real Estate
NASA Astrophysics Data System (ADS)
Yang, Jun; Zhu, Shi-Jiao
There is a significant need to detect and extract the graffito advertisement embedded in the housing images automatically. However, it is a hard job to separate the advertisement region well since housing images generally have complex background. In this paper, a detecting algorithm which uses multi-scale Gabor filters to identify graffito regions is proposed. Firstly, multi-scale Gabor filters with different directions are applied to housing images, then the approach uses these frequency data to find likely graffito regions using the relationship of different channels, it exploits the ability of different filters technique to solve the detection problem with low computational efforts. Lastly, the method is tested on several real estate images which are embedded graffito advertisement to verify its robustness and efficiency. The experiments demonstrate graffito regions can be detected quite well.
Improved flaw detection and characterization with difference thermography
NASA Astrophysics Data System (ADS)
Winfree, William P.; Zalameda, Joseph N.; Howell, Patricia A.
2011-05-01
Flaw detection and characterization with thermographic techniques in graphite polymer composites is often limited by localized variations in the thermographic response. Variations in properties such as acceptable porosity, variations in fiber volume content and surface polymer thickness result in variations in the thermal response that in general cause significant variations in the initial thermal response. These variations result in a noise floor that increases the difficulty of detecting and characterizing deeper flaws. The paper investigates comparing thermographic responses taken before and after a change in state in a composite to improve the detection of subsurface flaws. A method is presented for registration of the responses before finding the difference. A significant improvement in the detectability is achieved by comparing the differences in response. Examples of changes in state due to application of a load and impact are presented.
Improved Flaw Detection and Characterization with Difference Thermography
NASA Technical Reports Server (NTRS)
Winfree, William P.; Zalameda, Joseph N.; Howell, Patricia A.
2011-01-01
Flaw detection and characterization with thermographic techniques in graphite polymer composites is often limited by localized variations in the thermographic response. Variations in properties such as acceptable porosity, variations in fiber volume content and surface polymer thickness result in variations in the thermal response that in general cause significant variations in the initial thermal response. These variations result in a noise floor that increases the difficulty of detecting and characterizing deeper flaws. The paper investigates comparing thermographic responses taken before and after a change in state in a composite to improve the detection of subsurface flaws. A method is presented for registration of the responses before finding the difference. A significant improvement in the detectability is achieved by comparing the differences in response. Examples of changes in state due to application of a load and impact are presented.
Measuring economic outcomes of alcohol treatment using the Economic Form 90.
Bray, Jeremy W; Zarkin, Gary A; Miller, William R; Mitra, Debanjali; Kivlahan, Daniel R; Martin, Daniel J; Couper, David J; Cisler, Ron A
2007-03-01
This article assesses the ability of the economic outcome measures in the Economic Form 90 to detect differences across levels of alcohol dependence as measured by the Alcohol Dependence Scale. We used baseline data from the Combining Medications and Behavioral Interventions (COMBINE) Study, a large, multisite clinical trial, to assess the extent to which the economic items on the Economic Form 90 instrument can detect differences across levels of alcohol dependence. After adjusting for differences in demographic characteristics, the Economic Form 90 can detect significant differences across a range of dependence severity levels for the economic outcomes of inpatient medical care, emergency-department medical care, behavioral health care, being on parole or probation, and missed workdays, conditional on being employed. We did not detect significant differences across dependence severity for employment status, outpatient medical care, other criminal justice involvement, or motor vehicle accidents. The Economic Form 90 can identify differences in many economic outcomes associated with differing levels of alcohol dependence. This suggests that the Economic Form 90 may be useful in assessing changes in economic outcomes that result from changes in alcohol dependence.
NASA Astrophysics Data System (ADS)
Lartizien, Carole; Marache-Francisco, Simon; Prost, Rémy
2012-02-01
Positron emission tomography (PET) using fluorine-18 deoxyglucose (18F-FDG) has become an increasingly recommended tool in clinical whole-body oncology imaging for the detection, diagnosis, and follow-up of many cancers. One way to improve the diagnostic utility of PET oncology imaging is to assist physicians facing difficult cases of residual or low-contrast lesions. This study aimed at evaluating different schemes of computer-aided detection (CADe) systems for the guided detection and localization of small and low-contrast lesions in PET. These systems are based on two supervised classifiers, linear discriminant analysis (LDA) and the nonlinear support vector machine (SVM). The image feature sets that serve as input data consisted of the coefficients of an undecimated wavelet transform. An optimization study was conducted to select the best combination of parameters for both the SVM and the LDA. Different false-positive reduction (FPR) methods were evaluated to reduce the number of false-positive detections per image (FPI). This includes the removal of small detected clusters and the combination of the LDA and SVM detection maps. The different CAD schemes were trained and evaluated based on a simulated whole-body PET image database containing 250 abnormal cases with 1230 lesions and 250 normal cases with no lesion. The detection performance was measured on a separate series of 25 testing images with 131 lesions. The combination of the LDA and SVM score maps was shown to produce very encouraging detection performance for both the lung lesions, with 91% sensitivity and 18 FPIs, and the liver lesions, with 94% sensitivity and 10 FPIs. Comparison with human performance indicated that the different CAD schemes significantly outperformed human detection sensitivities, especially regarding the low-contrast lesions.
Detection of circulating tumor cells using oHSV1-hTERT-GFP in lung cancer.
Gao, Hongjun; Liu, Wenjing; Yang, Shaoxing; Zhang, Wen; Li, Xiaoyan; Qin, Haifeng; Wang, Weixia; Zhao, Changyun
2018-01-01
This study was conducted to evaluate the clinical utility of the oHSV1-hTERT-GFP circulating tumor cell (CTC) detection method in the peripheral blood of patients with lung cancer by comparing its sensitivity to the CellSearch CTC detection method. The oHSV1-hTERT-GFP and CellSearch CTC detection methods were compared using peripheral blood samples of patients pathologically diagnosed with lung cancer. A total of 240 patients with lung cancer were recruited, including 89 patients who were newly diagnosed and 151 patients who had previously received treatment. Sixty-six newly diagnosed patients were evaluated using both methods. The CTC detection rates were 71.2% and 33.3% using the oHSV1-hTERT-GFP and CellSearch methods, respectively; this difference was statistically significant (P = 0.000). Among the entire cohort (n = 240), the CTC detection rate using the oHSV1-hTERT-GFP method was 76.3%, with a CTC count of 0-81. The CTC detection rates were 76.7%, 68.9%, and 76.3% in patients with squamous cell carcinoma, adenocarcinoma, and small cell lung cancer, respectively. There was no statistically significant difference in the CTC detection rates between these different pathological subtypes (P = 0.738). The CTC detection rates of 79.8% and 74.4% in patients with stage I-III and IV lung cancer, respectively, were not significantly different (P = 0.427). The oHSV1-hTERT-GFP method is highly effective for detecting CTCs in patients with lung cancer, independent of pathological type and disease stage, and is ideal for large-scale clinical applications. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.
Li, Fengling; Jiang, Weiqian; Wang, Tian-Yi; Xie, Taorong; Yao, Haishan
2018-05-21
In the primary visual cortex (V1), neuronal responses to stimuli within the receptive field (RF) are modulated by stimuli in the RF surround. A common effect of surround modulation is surround suppression, which is dependent on the feature difference between stimuli within and surround the RF and is suggested to be involved in the perceptual phenomenon of figure-ground segregation. In this study, we examined the relationship between feature-specific surround suppression of V1 neurons and figure detection behavior based on figure-ground feature difference. We trained freely moving mice to perform a figure detection task using figure and ground gratings that differed in spatial phase. The performance of figure detection increased with the figure-ground phase difference, and was modulated by stimulus contrast. Electrophysiological recordings from V1 in head-fixed mice showed that the increase in phase difference between stimuli within and surround the RF caused a reduction in surround suppression, which was associated with an increase in V1 neural discrimination between stimuli with and without RF-surround phase difference. Consistent with the behavioral performance, the sensitivity of V1 neurons to RF-surround phase difference could be influenced by stimulus contrast. Furthermore, inhibiting V1 by optogenetically activating either parvalbumin (PV)- or somatostatin (SOM)-expressing inhibitory neurons both decreased the behavioral performance of figure detection. Thus, the phase-specific surround suppression in V1 represents a neural correlate of figure detection behavior based on figure-ground phase discontinuity. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.
Detection and classification of underwater targets by echolocating dolphins
NASA Astrophysics Data System (ADS)
Au, Whitlow
2003-10-01
Many experiments have been performed with echolocating dolphins to determine their target detection and discrimination capabilities. Target detection experiments have been performed in a naturally noisy environment, with masking noise and with both phantom echoes and masking noise, and in reverberation. The echo energy to rms noise spectral density for the Atlantic bottlenose dolphin (Tursiops truncatus) at the 75% correct response threshold is approximately 7.5 dB whereas for the beluga whale (Delphinapterus leucas) the threshold is approximately 1 dB. The dolphin's detection threshold in reverberation is approximately 2.5 dB vs 2 dB for the beluga. The difference in performance between species can probably be ascribed to differences in how both species perceived the task. The bottlenose dolphin may be performing a combination detection/discrimination task whereas the beluga may be performing a simple detection task. Echolocating dolphins also have the capability to make fine discriminate of target properties such as wall thickness difference of water-filled cylinders and material differences in metallic plates. The high resolution property of the animal's echolocation signals and the high dynamic range of its auditory system are important factors in their outstanding discrimination capabilities.
NASA Astrophysics Data System (ADS)
Ghosh, Soumen; Khan, Mehebub Ali; Ganguly, Aniruddha; Masum, Abdulla Al; Alam, Md. Akhtarul; Guchhait, Nikhil
2018-02-01
Two amido-schiff bases (3-Hydroxy-naphthalene-2-carboxylic acid pyren-1-ylmethylene-hydrazide and Naphthalene-2-carboxylic acid pyren-1-ylmethylene-hydrazide) have been synthesized having a common structural unit and only differs by a -OH group in the naphthalene ring. Both of them can detect Cu2 + ion selectively in semi-aqueous medium in distinctly different output modes (one detects Cu2 + by naked-eye color change where as the other detects Cu2 + by fluorescence enhancement). The difference in the binding of Cu 2 + with the compounds is the reason for this observation. The detection limit is found to be micromolar region for compound which contains -OH group whereas the compound without -OH group detects copper in nano-molar region. DFT calculations have been performed in order to demonstrate the structure of the compounds and their copper complexes. Practical utility has been explored by successful paper strip response of both the compounds. The biological applications have been evaluated in RAW 264.7.
Single molecule transistor based nanopore for the detection of nicotine
NASA Astrophysics Data System (ADS)
Ray, S. J.
2014-12-01
A nanopore based detection methodology was proposed and investigated for the detection of Nicotine. This technique uses a Single Molecular Transistor working as a nanopore operational in the Coulomb Blockade regime. When the Nicotine molecule is pulled through the nanopore area surrounded by the Source(S), Drain (D), and Gate electrodes, the charge stability diagram can detect the presence of the molecule and is unique for a specific molecular structure. Due to the weak coupling between the different electrodes which is set by the nanopore size, the molecular energy states stay almost unaffected by the electrostatic environment that can be realised from the charge stability diagram. Identification of different orientation and position of the Nicotine molecule within the nanopore area can be made from specific regions of overlap between different charge states on the stability diagram that could be used as an electronic fingerprint for detection. This method could be advantageous and useful to detect the presence of Nicotine in smoke which is usually performed using chemical chromatography techniques.
Infrared target tracking via weighted correlation filter
NASA Astrophysics Data System (ADS)
He, Yu-Jie; Li, Min; Zhang, JinLi; Yao, Jun-Ping
2015-11-01
Design of an effective target tracker is an important and challenging task for many applications due to multiple factors which can cause disturbance in infrared video sequences. In this paper, an infrared target tracking method under tracking by detection framework based on a weighted correlation filter is presented. This method consists of two parts: detection and filtering. For the detection stage, we propose a sequential detection method for the infrared target based on low-rank representation. For the filtering stage, a new multi-feature weighted function which fuses different target features is proposed, which takes the importance of the different regions into consideration. The weighted function is then incorporated into a correlation filter to compute a confidence map more accurately, in order to indicate the best target location based on the detection results obtained from the first stage. Extensive experimental results on different video sequences demonstrate that the proposed method performs favorably for detection and tracking compared with baseline methods in terms of efficiency and accuracy.
An experimental validation of a statistical-based damage detection approach.
DOT National Transportation Integrated Search
2011-01-01
In this work, a previously-developed, statistical-based, damage-detection approach was validated for its ability to : autonomously detect damage in bridges. The damage-detection approach uses statistical differences in the actual and : predicted beha...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almasi, Gheorghe; Blumrich, Matthias Augustin; Chen, Dong
Methods and apparatus perform fault isolation in multiple node computing systems using commutative error detection values for--example, checksums--to identify and to isolate faulty nodes. When information associated with a reproducible portion of a computer program is injected into a network by a node, a commutative error detection value is calculated. At intervals, node fault detection apparatus associated with the multiple node computer system retrieve commutative error detection values associated with the node and stores them in memory. When the computer program is executed again by the multiple node computer system, new commutative error detection values are created and stored inmore » memory. The node fault detection apparatus identifies faulty nodes by comparing commutative error detection values associated with reproducible portions of the application program generated by a particular node from different runs of the application program. Differences in values indicate a possible faulty node.« less
Hippocampus duality: Memory and novelty detection are subserved by distinct mechanisms.
Barbeau, Emmanuel J; Chauvel, Patrick; Moulin, Christopher J A; Regis, Jean; Liégeois-Chauvel, Catherine
2017-04-01
The hippocampus plays a pivotal role both in novelty detection and in long-term memory. The physiological mechanisms underlying these behaviors have yet to be understood in humans. We recorded intracerebral evoked potentials within the hippocampus of epileptic patients (n = 10) during both memory and novelty detection tasks (targets in oddball tasks). We found that memory and detection tasks elicited late local field potentials in the hippocampus during the same period, but of opposite polarity (negative during novelty detection tasks, positive during memory tasks, ∼260-600 ms poststimulus onset, P < 0.05). Critically, these potentials had maximal amplitude on the same contact in the hippocampus for each patient. This pattern did not depend on the task as different types of memory and novelty detection tasks were used. It did not depend on the novelty of the stimulus or the difficulty of the task either. Two different hypotheses are discussed to account for this result: it is either due to the activation of CA1 pyramidal neurons by two different pathways such as the monosynaptic and trisynaptic entorhinal-hippocampus pathways, or to the activation of different neuronal populations, that is, differing either functionally (e.g., novelty/familiarity neurons) or located in different regions of the hippocampus (e.g., CA1/subiculum). In either case, these activities may integrate the activity of two distinct large-scale networks implementing externally or internally oriented, mutually exclusive, brain states. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L
2017-11-01
Milk and milk products are among the most important allergenic food ingredients, both in the United States and throughout the world; cheeses are among the most important of these milk products. Milk contains several major antigenic proteins, each with differing susceptibilities to proteolytic enzymes. The extent of proteolysis in cheese varies as a result of conditions during manufacture and ripening. Proteolysis has the potential to degrade antigenic and allergenic epitopes that are important for residue detection and elicitation of allergic reactions. Commercial enzyme-linked immunosorbent assays (ELISAs) are not currently validated for use in detecting residues in hydrolyzed or fermented food products. Eighteen retail cheeses produced using 5 different styles of fermentation were investigated for detectable milk protein residues with 4 commercial ELISA kits. Mozzarella, Swiss, Blue, Limburger, and Brie cheeses were assessed. The Neogen Veratox® Casein and Neogen Veratox® Total Milk kits were capable of detecting milk residues in most cheeses evaluated, including blue-veined cheeses that exhibit extensive proteolysis. The other 2 ELISA kits evaluated, r-Biopharm® Fast Casein and ELISA Systems™ Casein, can detect milk residues in cheeses other than blue-veined varieties. ELISA results cannot be quantitatively compared among kits. The quantitative reliability of ELISA results in detection of cheese residues is questionable, but some methods are sufficiently robust to use as a semi-quantitative indication of proper allergen control for the validation of cleaning programs in industry settings. Many commercially available enzyme-linked immunosorbent assays (ELISAs) are not validated for detection of allergenic residues in fermented or hydrolyzed products. This research seeks to determine if commercial milk ELISAs can detect milk residues in varieties of cheese that have undergone different styles of fermentation and different degrees of proteolysis. Only certain milk ELISA kits are capable of detecting residues in all varieties of cheese. However, commercial milk ELISA kits are capable of semiquantitative detection of cheese residues in foods, or in industry settings for the validation of allergen cleaning programs. © 2017 Institute of Food Technologists®.
Structured-illumination reflectance imaging (SIRI) for enhanced detection of fresh bruises in apples
USDA-ARS?s Scientific Manuscript database
A structured-illumination reflectance imaging technique was developed for the detection of fresh bruises in apples. Experiments were first conducted on a strongly scattering nylon sample embedded with foreign objects of different sizes at different depths, and then on apples of two different cultiva...
Activation of Organic Photovoltaic Light Detectors Using Bend Leakage from Optical Fibers.
Griffith, Matthew J; Willis, Matthew S; Kumar, Pankaj; Holdsworth, John L; Bezuidenhout, Henco; Zhou, Xiaojing; Belcher, Warwick; Dastoor, Paul C
2016-03-01
This work investigates the detection and subsequent utilization of leaked light from bends in a silica optical fiber using organic photovoltaic detectors. The optic power lost by single mode and multimode silica optical fibers was calibrated for bend radii between 1 and 7 mm for 532 and 633 nm light, exhibiting excellent agreement with previous theoretical solutions. The spatial location of maximum power leakage on the exterior of the fiber was found to exist in the same plane as the fiber, with a 10° offset from the normal. Two different organic photovoltaic detectors fabricated using a poly(3-hexylthiophene):indene-C60-bisadduct donor-acceptor blend cast from chloroform and chlorobenzene were fabricated to detect the leaked light. The two detectors exhibited different photovoltaic performances, predominantly due to different active layer thicknesses. Both devices showed sensitivity to leakage light, exhibiting voltages between 200 and 300 mV in response to leaked light from the fiber. The temporal responses of the devices were observed to differ, with a rise time from 10% to 90% of maximum voltage of 1430 μs for the chlorobenzene device, and a corresponding rise time of 490 μs for the higher performing chloroform device. The two OPVs were used to simultaneously detect leaked light from induced bends in the optical fiber, with the differing temporal profiles employed to create a unique time-correlated detection signal with enhanced security. The delay between detection of each OPV voltage could be systematically varied, allowing for either a programmable and secure single detection signal or triggering of multiple events with variable time resolution. The results reported in this study present exciting avenues toward the deployment of this simple and noninvasive optical detection system in a range of different applications.
Zhang, Chu; Feng, Xuping; Wang, Jian; Liu, Fei; He, Yong; Zhou, Weijun
2017-01-01
Detection of plant diseases in a fast and simple way is crucial for timely disease control. Conventionally, plant diseases are accurately identified by DNA, RNA or serology based methods which are time consuming, complex and expensive. Mid-infrared spectroscopy is a promising technique that simplifies the detection procedure for the disease. Mid-infrared spectroscopy was used to identify the spectral differences between healthy and infected oilseed rape leaves. Two different sample sets from two experiments were used to explore and validate the feasibility of using mid-infrared spectroscopy in detecting Sclerotinia stem rot (SSR) on oilseed rape leaves. The average mid-infrared spectra showed differences between healthy and infected leaves, and the differences varied among different sample sets. Optimal wavenumbers for the 2 sample sets selected by the second derivative spectra were similar, indicating the efficacy of selecting optimal wavenumbers. Chemometric methods were further used to quantitatively detect the oilseed rape leaves infected by SSR, including the partial least squares-discriminant analysis, support vector machine and extreme learning machine. The discriminant models using the full spectra and the optimal wavenumbers of the 2 sample sets were effective for classification accuracies over 80%. The discriminant results for the 2 sample sets varied due to variations in the samples. The use of two sample sets proved and validated the feasibility of using mid-infrared spectroscopy and chemometric methods for detecting SSR on oilseed rape leaves. The similarities among the selected optimal wavenumbers in different sample sets made it feasible to simplify the models and build practical models. Mid-infrared spectroscopy is a reliable and promising technique for SSR control. This study helps in developing practical application of using mid-infrared spectroscopy combined with chemometrics to detect plant disease.
Comparing viral metagenomics methods using a highly multiplexed human viral pathogens reagent
Li, Linlin; Deng, Xutao; Mee, Edward T.; Collot-Teixeira, Sophie; Anderson, Rob; Schepelmann, Silke; Minor, Philip D.; Delwart, Eric
2014-01-01
Unbiased metagenomic sequencing holds significant potential as a diagnostic tool for the simultaneous detection of any previously genetically described viral nucleic acids in clinical samples. Viral genome sequences can also inform on likely phenotypes including drug susceptibility or neutralization serotypes. In this study, different variables of the laboratory methods often used to generate viral metagenomics libraries on the efficiency of viral detection and virus genome coverage were compared. A biological reagent consisting of 25 different human RNA and DNA viral pathogens was used to estimate the effect of filtration and nuclease digestion, DNA/RNA extraction methods, pre-amplification and the use of different library preparation kits on the detection of viral nucleic acids. Filtration and nuclease treatment led to slight decreases in the percentage of viral sequence reads and number of viruses detected. For nucleic acid extractions silica spin columns improved viral sequence recovery relative to magnetic beads and Trizol extraction. Pre-amplification using random RT-PCR while generating more viral sequence reads resulted in detection of fewer viruses, more overlapping sequences, and lower genome coverage. The ScriptSeq library preparation method retrieved more viruses and a greater fraction of their genomes than the TruSeq and Nextera methods. Viral metagenomics sequencing was able to simultaneously detect up to 22 different viruses in the biological reagent analyzed including all those detected by qPCR. Further optimization will be required for the detection of viruses in biologically more complex samples such as tissues, blood, or feces. PMID:25497414
Spatial and Temporal Monitoring Resolutions for CO2 Leakage Detection at Carbon Storage Sites
NASA Astrophysics Data System (ADS)
Yang, Y. M.; Dilmore, R. M.; Daley, T. M.; Carroll, S.; Mansoor, K.; Gasperikova, E.; Harbert, W.; Wang, Z.; Bromhal, G. S.; Small, M.
2016-12-01
Different leakage monitoring techniques offer different strengths in detection sensitivity, coverage, feedback time, cost, and technology availability, such that they may complement each other when applied together. This research focuses on quantifying the spatial coverage and temporal resolution of detection response for several geophysical remote monitoring and direct groundwater monitoring techniques for an optimal monitoring plan for CO2 leakage detection. Various monitoring techniques with different monitoring depths are selected: 3D time-lapse seismic survey, wellbore pressure, groundwater chemistry and soil gas. The spatial resolution in terms of leakage detectability is quantified through the effective detection distance between two adjacent monitors, given the magnitude of leakage and specified detection probability. The effective detection distances are obtained either from leakage simulations with various monitoring densities or from information garnered from field test data. These spatial leakage detection resolutions are affected by physically feasible monitoring design and detection limits. Similarly, the temporal resolution, in terms of leakage detectability, is quantified through the effective time to positive detection of a given size of leak and a specified detection probability, again obtained either from representative leakage simulations with various monitoring densities or from field test data. The effective time to positive detection is also affected by operational feedback time (associated with sampling, sample analysis and data interpretation), with values obtained mainly through expert interviews and literature review. In additional to the spatial and temporal resolutions of these monitoring techniques, the impact of CO2 plume migration speed and leakage detection sensitivity of each monitoring technique are also discussed with consideration of how much monitoring is necessary for effective leakage detection and how these monitoring techniques can be better combined in a time-space framework. The results of the spatial and temporal leakage detection resolutions for several geophysical monitoring techniques and groundwater monitoring are summarized to inform future monitoring designs at carbon storage sites.
A pdf-Free Change Detection Test Based on Density Difference Estimation.
Bu, Li; Alippi, Cesare; Zhao, Dongbin
2018-02-01
The ability to detect online changes in stationarity or time variance in a data stream is a hot research topic with striking implications. In this paper, we propose a novel probability density function-free change detection test, which is based on the least squares density-difference estimation method and operates online on multidimensional inputs. The test does not require any assumption about the underlying data distribution, and is able to operate immediately after having been configured by adopting a reservoir sampling mechanism. Thresholds requested to detect a change are automatically derived once a false positive rate is set by the application designer. Comprehensive experiments validate the effectiveness in detection of the proposed method both in terms of detection promptness and accuracy.
Multi-dynamic range compressional wave detection using optical-frequency comb
NASA Astrophysics Data System (ADS)
Minamikawa, Takeo; Masuoka, Takashi; Oe, Ryo; Nakajima, Yoshiaki; Yamaoka, Yoshihisa; Minoshima, Kaoru; Yasui, Takeshi
2018-02-01
Compressional wave detection is useful means for health monitoring of building, detection of abnormal vibration of moving objects, defect evaluation, and biomedical imaging such as echography and photoacoustic imaging. The frequency of the compressional wave is varied from quasi-static to a few tens of megahertz depending on applications. Since the dynamic range of general compressional wave detectors is limited, we need to choose a proper compressional wave detector depending on applications. For the compressional wave detection with wide dynamic range, two or more detectors with different detection ranges is required. However, these detectors with different detection ranges generally has different accuracy and precision, disabling the seamless detection over these detection ranges. In this study, we proposed a compressional wave detector employing optical frequency comb (OFC). The compressional wave was sensed with a part of an OFC cavity, being encoded into OFC. The spectrally encoded OFC was converted to radio-frequency by the frequency link nature of OFC. The compressional wave-encoded radio-frequency can therefore be directly measured with a high-speed photodetector. To enhance the dynamic range of the compressional wave detection, we developed a cavityfeedback-based system and a phase-sensitive detection system, both of which the accuracy and precision are coherently linked to these of the OFC. We provided a proof-of-principle demonstration of the detection of compressional wave from quasi-static to ultrasound wave by using the OFC-based compressional wave sensor. Our proposed approach will serve as a unique and powerful tool for detecting compressional wave versatile applications in the future.
Li, Xing-Qiao; Liu, Xue-Wei; Zhou, Tao; Pei, Xiao-Fang
2017-11-01
To investigate the prevalence and gene characteristics of different groups of human parainfluenza virus (HPIV) infection in hospitalized adults with acute respiratory tract infections (ARI). RT-PCR was used to detect HPIV hemagglutinin (HA) DNA,which was extracted from sputum samples of 1 039 adult patients with ARI from March,2014 to June,2016. The HA gene amplified from randomly selected positive samples were sequenced to analyze the homology and variation. 10.6% (110/1 039) of these samples were positive for HPIV,including 8 cases of HPIV-1,22 cases of HPIV-2,46 cases of HPIV-3 and 34 cases of HPIV-4. Detectable rate varied among different groups of HPIV according to seasons of the year and ages of patients. No significant differences were found between the positive samples and the reference sequences. Compared with different reference strains of different regions,the genetic distance of nucleotide is the smallest between the strains tested in this study and the reference strains of other provinces and cities in China. In Chengdu region,HPIV virus is highly detected in ARI,all subtypes were detected with HPIV-3 being the main subtype.
NASA Technical Reports Server (NTRS)
Panda, Binayak; Gorti, Sridhar
2013-01-01
A number of research instruments are available at NASA's Marshall Space Flight Center (MSFC) to support ISS researchers and their investigations. These modern analytical tools yield valuable and sometimes new informative resulting from sample characterization. Instruments include modern scanning electron microscopes equipped with field emission guns providing analytical capabilities that include angstron-level image resolution of dry, wet and biological samples. These microscopes are also equipped with silicon drift X-ray detectors (SDD) for fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations in crystalline alloys. Sample chambers admit large samples, provide variable pressures for wet samples, and quantitative analysis software to determine phase relations. Advances in solid-state electronics have also facilitated improvements for surface chemical analysis that are successfully employed to analyze metallic materials and alloys, ceramics, slags, and organic polymers. Another analytical capability at MSFC is a mganetic sector Secondary Ion Mass Spectroscopy (SIMS) that quantitatively determines and maps light elements such as hydrogen, lithium, and boron along with their isotopes, identifies and quantifies very low level impurities even at parts per billion (ppb) levels. Still other methods available at MSFC include X-ray photo-electron spectroscopy (XPS) that can determine oxidation states of elements as well as identify polymers and measure film thicknesses on coated materials, Scanning Auger electron spectroscopy (SAM) which combines surface sensitivity, spatial lateral resolution (approximately 20 nm), and depth profiling capabilities to describe elemental compositions in near surface regions and even the chemical state of analyzed atoms. Conventional Transmission Electron Microscope (TEM) for observing internal microstructures at very high magnifications and the Electron Probe Micro-analyzer (EPMA) for very precise microanalysis are available as needed by the researcher. Space Station researchers are invited to work with MSFC in analyzing their samples using these techniques.
NASA Technical Reports Server (NTRS)
Klingelhoefer, G.; Morris, R. V.; Blumers, M; Bernhardt, B.; Graff, T.
2014-01-01
The 2010 and 2012 In-Situ Resource Utilization Analogue Test (ISRU) [1] on the Mauna Kea volcano in Hawai'i was coordinated by the Northern Centre for Advanced Technology (NORCAT) in collaboration with the Canadian Space Agency (CSA), the German Aerospace Center (DLR), and the National Aeronautics and Space Administration (NASA), through the PISCES program. Several instruments were tested as reference candidates for future analogue testing at the new field test site at the Mauna Kea volcano in Hawai'i. The fine-grained, volcanic nature of the material is a suitable lunar and martian analogue, and can be used to test excavation, site preparation, and resource utilization techniques. The 2010 location Pu'u Hiwahine, a cinder cone located below the summit of Mauna Kea (19deg45'39.29" N, 155deg28'14.56" W) at an elevation of 2800 m, provides a large number of slopes, rock avalanches, etc. to perform mobility tests, site preparation or resource prospecting. Besides hardware testing of technologies and systems related to resource identification, also in situ science measurements played a significant role in integration of ISRU and science instruments. For the advanced Mössbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform Xray fluorescence analysis simultaneously to Mössbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The 2010 and 2012 field campaigns demonstrated that in-situ Mössbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.
Benefits Assessment of Algorithmically Combining Generic High Altitude Airspace Sectors
NASA Technical Reports Server (NTRS)
Bloem, Michael; Gupta, Pramod; Lai, Chok Fung; Kopardekar, Parimal
2009-01-01
In today's air traffic control operations, sectors that have traffic demand below capacity are combined so that fewer controller teams are required to manage air traffic. Controllers in current operations are certified to control a group of six to eight sectors, known as an area of specialization. Sector combinations are restricted to occur within areas of specialization. Since there are few sector combination possibilities in each area of specialization, human supervisors can effectively make sector combination decisions. In the future, automation and procedures will allow any appropriately trained controller to control any of a large set of generic sectors. The primary benefit of this will be increased controller staffing flexibility. Generic sectors will also allow more options for combining sectors, making sector combination decisions difficult for human supervisors. A sector-combining algorithm can assist supervisors as they make generic sector combination decisions. A heuristic algorithm for combining under-utilized air space sectors to conserve air traffic control resources has been described and analyzed. Analysis of the algorithm and comparisons with operational sector combinations indicate that this algorithm could more efficiently utilize air traffic control resources than current sector combinations. This paper investigates the benefits of using the sector-combining algorithm proposed in previous research to combine high altitude generic airspace sectors. Simulations are conducted in which all the high altitude sectors in a center are allowed to combine, as will be possible in generic high altitude airspace. Furthermore, the algorithm is adjusted to use a version of the simplified dynamic density (SDD) workload metric that has been modified to account for workload reductions due to automatic handoffs and Automatic Dependent Surveillance Broadcast (ADS-B). This modified metric is referred to here as future simplified dynamic density (FSDD). Finally, traffic demand sets with increased air traffic demand are used in the simulations to capture the expected growth in air traffic demand by the mid-term.
Waked, Karl; Schepens, Marc
2018-01-01
During open thoracoabdominal aortic aneurysm repair (OTAAAR), there is an inevitable organ ischemic period that occurs when the abdominal arteries are being reattached to the aortic graft. Despite various protective techniques, the incidence of renal and visceral complications remains substantial. This state-of-the-art review gives an overview of the current and most evidence-based organ protection methods during OTAAAR, based on the most recent publications and personal experience. An electronic search was performed in four medical databases, using the following MeSH terms: thoracoabdominal aneurysm, TAAAR, visceral protection, renal protection, kidney, perfusion, and intestines. Every publication type was considered. The literature search was ended on August 31st, 2017. The left heart bypass (LHB) is currently the most frequent adjunct to provide distal aortic perfusion (DAP) during aortic clamping. Together with systemic hypothermia, it forms the cornerstone in organ protection during aortic clamping. Further renal protection can be obtained by selective renal perfusion (SRP) with cold blood or cold crystalloid solution, the latter enriched with mannitol. The perfusion should be administered in a volume- and pressure-controlled way and, if possible, by use of a pulsatile pump. Selective visceral perfusion (SVP) is not routinely used, as it does not provide adequate blood flow for visceral protection. The best way to protect the intestines is by minimizing the ischemic time. The preservation of renal and visceral function after OTAAAR can only be obtained with specific strategies before, during, and after the operation. This involves a series of measures, including selective digestive decontamination (SDD), avoidance of nephrotoxic drugs, minimizing the renal and intestinal ischemic time, systemic cooling, avoidance of hemodynamic instability, and regional protective perfusion of the kidneys. Future innovations in catheters, cardiac bypass flow types, mechanical components, hybrid vascular grafts, and pharmaceutical protection measures will hopefully further reduce organ complications.
Institóris, László; Árok, Zsófia; Seprenyi, Katalin; Varga, Tibor; Sára-Klausz, Gabriella; Keller, Éva; Tóth, Réka A; Sala, Leonardo; Kereszty, Éva; Róna, Kálmán
2015-03-01
Identification of abuse and frequency patterns of stimulant designer drugs (SDDs) provides important information for their risk assessment and legislative control. In the present study urine and/or blood samples of suspected drug users in criminal cases were analysed by GC-MS for 38 SDDs, and for the most frequent illicit and psychoactive licit drugs in Hungary. Between July 2012 and June 2013, 2744 suspected drug users were sampled in Budapest and during 2012 and 2013, 774 persons were sampled in South-East Hungary (Csongrád County - neighbour the Romanian and Serbian borders). In Budapest 71.4% of cases, and in South-East Hungary 61% of cases were positive for at least one substance. Pentedrone was the most frequent SDD in both regions; however, the frequency distribution of the remaining drugs was highly diverse. SDDs were frequently present in combination with other drugs - generally with amphetamine or other stimulants, cannabis and/or benzodiazepines. The quarterly distribution of positive samples indicated remarkable seasonal changes in the frequency and pattern of consumption. Substances placed on the list of illicit drugs (mephedrone, 4-fluoro-amphetamine, MDPV, methylone, 4-MEC) showed a subsequent drop in frequency and were replaced by other SDDs (pentedrone, 3-MMC, methiopropamine, etc.). Newly identified compounds from seized materials were added to the list of new psychoactive substances ("Schedule C"). While the risk assessment of substances listed in Schedule C has to be performed within 2 years after scheduling, continuous monitoring of their presence and frequency among drug users is essential. In summary, our results suggest which substances should be dropped from the list of SDDs measured in biological samples; while the appearance of new substances from seized materials indicate the need for developing adequate standard analytical methods. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Cankar, Katarina; Chauvensy-Ancel, Valérie; Fortabat, Marie-Noelle; Gruden, Kristina; Kobilinsky, André; Zel, Jana; Bertheau, Yves
2008-05-15
Detection of nonauthorized genetically modified organisms (GMOs) has always presented an analytical challenge because the complete sequence data needed to detect them are generally unavailable although sequence similarity to known GMOs can be expected. A new approach, differential quantitative polymerase chain reaction (PCR), for detection of nonauthorized GMOs is presented here. This method is based on the presence of several common elements (e.g., promoter, genes of interest) in different GMOs. A statistical model was developed to study the difference between the number of molecules of such a common sequence and the number of molecules identifying the approved GMO (as determined by border-fragment-based PCR) and the donor organism of the common sequence. When this difference differs statistically from zero, the presence of a nonauthorized GMO can be inferred. The interest and scope of such an approach were tested on a case study of different proportions of genetically modified maize events, with the P35S promoter as the Cauliflower Mosaic Virus common sequence. The presence of a nonauthorized GMO was successfully detected in the mixtures analyzed and in the presence of (donor organism of P35S promoter). This method could be easily transposed to other common GMO sequences and other species and is applicable to other detection areas such as microbiology.
A survey of landmine detection using hyperspectral imaging
NASA Astrophysics Data System (ADS)
Makki, Ihab; Younes, Rafic; Francis, Clovis; Bianchi, Tiziano; Zucchetti, Massimo
2017-02-01
Hyperspectral imaging is a trending technique in remote sensing that finds its application in many different areas, such as agriculture, mapping, target detection, food quality monitoring, etc. This technique gives the ability to remotely identify the composition of each pixel of the image. Therefore, it is a natural candidate for the purpose of landmine detection, thanks to its inherent safety and fast response time. In this paper, we will present the results of several studies that employed hyperspectral imaging for the purpose of landmine detection, discussing the different signal processing techniques used in this framework for hyperspectral image processing and target detection. Our purpose is to highlight the progresses attained in the detection of landmines using hyperspectral imaging and to identify possible perspectives for future work, in order to achieve a better detection in real-time operation mode.
Early detection of mine fire in underground by using smell detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohga, Kotaro; Higuchi, Kiyoshi
1995-12-31
In our laboratory, a new detection system using smell detectors was developed to detect the spontaneous combustion of coal and the combustion of other materials used underground. Laboratory experiments were carried out on several kinds of coals, including South African coals, and machine oil, wood and rubber used in belt conveyers. The following results were obtained: (1) Spontaneous combustion of coal can be detected earlier by smell detectors than by conventional CO detection methods. (2) There were no differences in the results using different kinds of coal. (3) Combustion d other materials can also be detected earlier by this systemmore » than by conventional detectors for gas and smoke. (4) Use of this detection system enables one to discern the source of the combustion gases, whether it be coal, wood, oil or rubber.« less
Shi, Zhenghao; Ma, Jiejue; Feng, Yaning; He, Lifeng; Suzuki, Kenji
2015-11-01
MTANN (Massive Training Artificial Neural Network) is a promising tool, which applied to eliminate false-positive for thoracic CT in recent years. In order to evaluate whether this method is feasible to eliminate false-positive of different CAD schemes, especially, when it is applied to commercial CAD software, this paper evaluate the performance of the method for eliminating false-positives produced by three different versions of commercial CAD software for lung nodules detection in chest radiographs. Experimental results demonstrate that the approach is useful in reducing FPs for different computer aided lung nodules detection software in chest radiographs.
Pesticides in Wyoming Groundwater, 2008-10
Eddy-Miller, Cheryl A.; Bartos, Timothy T.; Taylor, Michelle L.
2013-01-01
Groundwater samples were collected from 296 wells during 1995-2006 as part of a baseline study of pesticides in Wyoming groundwater. In 2009, a previous report summarized the results of the baseline sampling and the statistical evaluation of the occurrence of pesticides in relation to selected natural and anthropogenic (human-related) characteristics. During 2008-10, the U.S. Geological Survey, in cooperation with the Wyoming Department of Agriculture, resampled a subset (52) of the 296 wells sampled during 1995-2006 baseline study in order to compare detected compounds and respective concentrations between the two sampling periods and to evaluate the detections of new compounds. The 52 wells were distributed similarly to sites used in the 1995-2006 baseline study with respect to geographic area and land use within the geographic area of interest. Because of the use of different types of reporting levels and variability in reporting-level values during both the 1995-2006 baseline study and the 2008-10 resampling study, analytical results received from the laboratory were recensored. Two levels of recensoring were used to compare pesticides—a compound-specific assessment level (CSAL) that differed by compound and a common assessment level (CAL) of 0.07 microgram per liter. The recensoring techniques and values used for both studies, with the exception of the pesticide 2,4-D methyl ester, were the same. Twenty-eight different pesticides were detected in samples from the 52 wells during the 2008-10 resampling study. Pesticide concentrations were compared with several U.S. Environmental Protection Agency drinking-water standards or health advisories for finished (treated) water established under the Safe Drinking Water Act. All detected pesticides were measured at concentrations smaller than U.S. Environmental Protection Agency drinking-water standards or health advisories where applicable (many pesticides did not have standards or advisories). One or more pesticides were detected at concentrations greater than the CAL in water from 16 of 52 wells sampled (about 31 percent) during the resampling study. Detected pesticides were classified into one of six types: herbicides, herbicide degradates, insecticides, insecticide degradates, fungicides, or fungicide degradates. At least 95 percent of detected pesticides were classified as herbicides or herbicide degradates. The number of different pesticides detected in samples from the 52 wells was similar between the 1995-2006 baseline study (30 different pesticides) and 2008-2010 resampling study (28 different pesticides). Thirteen pesticides were detected during both studies. The change in the number of pesticides detected (without regard to which pesticide was detected) in groundwater samples from each of the 52 wells was evaluated and the number of pesticides detected in groundwater did not change for most of the wells (32). Of those that did have a difference between the two studies, 17 wells had more pesticide detections in groundwater during the 1995-2006 baseline study, whereas only 3 wells had more detections during the 2008-2010 resampling study. The difference in pesticide concentrations in groundwater samples from each of the 52 wells was determined. Few changes in concentration between the 1995-2006 baseline study and the 2008-2010 resampling study were seen for most detected pesticides. Seven pesticides had a greater concentration detected in the groundwater from the same well during the baseline sampling compared to the resampling study. Concentrations of prometon, which was detected in 17 wells, were greater in the baseline study sample compared to the resampling study sample from the same well 100 percent of the time. The change in the number of pesticides detected (without regard to which pesticide was detected) in groundwater samples from each of the 52 wells with respect to land use and geographic area was calculated. All wells with land use classified as agricultural had the same or a smaller number of pesticides detected in the resampling study compared to the baseline study. All wells in the Bighorn Basin geographic area also had the same or a smaller number of pesticides detected in the resampling study compared to the baseline study.
The difference of detecting water mist and smoke by electromagnetic wave in simulation experiments
NASA Astrophysics Data System (ADS)
Zhang, Jingdi; Cui, Bing; Xiao, Si
2015-10-01
Although mist is similar to smoke in morphology, their compositions are very different. Therefore there is a significant difference between mist and smoke when detected by electromagnetic wave. This paper puts forward a kind of feasible solution based on Ansoft HFSS software about how to determine the forest fire by distinguishing mist and smoke above the forest. The experiments simulate the difference between mist and smoke model when detected by electromagnetic wave in different wavelengths. We find the mist and smoke model cannot absorb or reflect electromagnetic wave efficiently in Megahertz band. While in Gigahertz band mist model began to absorb and reflect electromagnetic wave above 650 Gigahertz band, but no change in smoke model. And the biggest difference appears in Terahertz band.
Testing the importance of auditory detections in avian point counts
Brewster, J.P.; Simons, T.R.
2009-01-01
Recent advances in the methods used to estimate detection probability during point counts suggest that the detection process is shaped by the types of cues available to observers. For example, models of the detection process based on distance-sampling or time-of-detection methods may yield different results for auditory versus visual cues because of differences in the factors that affect the transmission of these cues from a bird to an observer or differences in an observer's ability to localize cues. Previous studies suggest that auditory detections predominate in forested habitats, but it is not clear how often observers hear birds prior to detecting them visually. We hypothesized that auditory cues might be even more important than previously reported, so we conducted an experiment in a forested habitat in North Carolina that allowed us to better separate auditory and visual detections. Three teams of three observers each performed simultaneous 3-min unlimited-radius point counts at 30 points in a mixed-hardwood forest. One team member could see, but not hear birds, one could hear, but not see, and the third was nonhandicapped. Of the total number of birds detected, 2.9% were detected by deafened observers, 75.1% by blinded observers, and 78.2% by nonhandicapped observers. Detections by blinded and nonhandicapped observers were the same only 54% of the time. Our results suggest that the detection of birds in forest habitats is almost entirely by auditory cues. Because many factors affect the probability that observers will detect auditory cues, the accuracy and precision of avian point count estimates are likely lower than assumed by most field ornithologists. ?? 2009 Association of Field Ornithologists.
[Detection of intraorbital foreign material using MDCT].
Hoffstetter, P; Friedrich, C; Framme, C; Hoffstetter, M; Zorger, N; Stierstorfer, K; Ross, C; Uller, W; Müller-Wille, R; Rennert, J; Jung, E M; Schreyer, A G
2011-06-01
To judge the possibilities of detection of orbital foreign bodies in multidetector CT (MDCT) with a focus on glass slivers. Experimental systematic measuring of Hounsfield Units (HU) of 20 different materials, containing 16 different types of glass with 4 different types of ophthalmic lenses among them. The measurements were performed using a standardized protocol with an orbita phantom being scanned with 16-slice MDCT. Using the resulting density values, the smallest detectable volume was calculated. Using this data we produced slivers of 5 different glass types in the sub-millimeter range and calculated their volume. Those micro-slivers underwent another CT scan using the same protocol as mentioned above to experimentally discern and confirm the detection limit for micro-slivers made of different materials. Glass has comparatively high density values of at least 2000 HU. The density of glasses with strong refraction is significantly higher and reaches up to 12 400 HU. We calculated a minimum detectable volume of 0.07 mm (3) for glass with a density of 2000 HU. Only glass slivers with a density higher than 8300 HU were experimentally detectable in the sub-millimeter range up to a volume as small as 0.01 mm (3). Less dense glass slivers could not be seen, even though their volume was above the theoretically calculated threshold for detection. Due to its high density of at least 2000 HU, glass is usually easily recognizable as an orbital foreign body. The detection threshold depends on the object's density and size and can be as low as 0.01 mm (3) in the case of glass with strong refraction and thus high density. The detection of glass as an orbital foreign body seems to be secure for slivers with a volume of at least 0.2 mm (3) for all types of glass. © Georg Thieme Verlag KG Stuttgart · New York.
ERIC Educational Resources Information Center
Morphew, Jason W.; Mestre, Jose P.; Ross, Brian H.; Strand, Natalie E.
2015-01-01
It is known that experts identify or perceive meaningful patterns in visual stimuli related to their domain of expertise. This study explores the speed with which experts and novices detect changes in physics diagrams. Since change detection depends on where individuals direct their attention, differences in the speed with which experts and…
ERIC Educational Resources Information Center
Cho, Sun-Joo; Preacher, Kristopher J.; Bottge, Brian A.
2015-01-01
Multilevel modeling (MLM) is frequently used to detect group differences, such as an intervention effect in a pre-test--post-test cluster-randomized design. Group differences on the post-test scores are detected by controlling for pre-test scores as a proxy variable for unobserved factors that predict future attributes. The pre-test and post-test…
Lee, Daniel J; Recabal, Pedro; Sjoberg, Daniel D; Thong, Alan; Lee, Justin K; Eastham, James A; Scardino, Peter T; Vargas, Hebert Alberto; Coleman, Jonathan; Ehdaie, Behfar
2016-09-01
We compared the diagnostic outcomes of magnetic resonance-ultrasound fusion and visually targeted biopsy for targeting regions of interest on prostate multiparametric magnetic resonance imaging. Patients presenting for prostate biopsy with regions of interest on multiparametric magnetic resonance imaging underwent magnetic resonance imaging targeted biopsy. For each region of interest 2 visually targeted cores were obtained, followed by 2 cores using a magnetic resonance-ultrasound fusion device. Our primary end point was the difference in the detection of high grade (Gleason 7 or greater) and any grade cancer between visually targeted and magnetic resonance-ultrasound fusion, investigated using McNemar's method. Secondary end points were the difference in detection rate by biopsy location using a logistic regression model and the difference in median cancer length using the Wilcoxon signed rank test. We identified 396 regions of interest in 286 men. The difference in the detection of high grade cancer between magnetic resonance-ultrasound fusion biopsy and visually targeted biopsy was -1.4% (95% CI -6.4 to 3.6, p=0.6) and for any grade cancer the difference was 3.5% (95% CI -1.9 to 8.9, p=0.2). Median cancer length detected by magnetic resonance-ultrasound fusion and visually targeted biopsy was 5.5 vs 5.8 mm, respectively (p=0.8). Magnetic resonance-ultrasound fusion biopsy detected 15% more cancers in the transition zone (p=0.046) and visually targeted biopsy detected 11% more high grade cancer at the prostate base (p=0.005). Only 52% of all high grade cancers were detected by both techniques. We found no evidence of a significant difference in the detection of high grade or any grade cancer between visually targeted and magnetic resonance-ultrasound fusion biopsy. However, the performance of each technique varied in specific biopsy locations and the outcomes of both techniques were complementary. Combining visually targeted biopsy and magnetic resonance-ultrasound fusion biopsy may optimize the detection of prostate cancer. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Mohamad, Saharuddin Bin; Nagasawa, Hideko; Sasaki, Hideyuki; Uto, Yoshihiro; Nakagawa, Yoshinori; Kawashima, Ken; Hori, Hitoshi
2003-01-01
Gc protein is the precursor for Gc protein-derived macrophage activating factor (GcMAF), with three phenotypes: Gc1f, Gc1s and Gc2, based on its electrophoretic mobility. The difference in electrophoretic mobility is because of the difference in its posttranslational sugar moiety composition. We compared the difference between Gc protein and GcMAF electrophoretic mobility using the isoelectric focusing (IEF) method. The tumoricidal activity of GcMAF-treated macrophage was evaluated after coculture with L-929 cell. The tumoricidal mechanism was investigated using TNF bioassay and nitric oxide (NO) release. The difference in Gc protein and GcMAF electrophoretic mobility was detected. The tumoricidal activity of GcMAF-treated macrophage was detected, but no release of TNF and NO was detected. The difference of isoelectric focusing mobility in Gc protein and GcMAF would be useful to develop a GcMAF detection method. GcMAF increased macrophage tumoricidal activity but TNF and NO release were not involved in the mechanism.
Sensor for detecting changes in magnetic fields
Praeg, W.F.
1980-02-26
A sensor is described for detecting changes in the magnetic field of the equilibrium-field coil of a Tokamak plasma device that comprises a pair of bifilar wires disposed circumferentially, one inside and one outside the equilibrium-field coil. Each is shorted at one end. The difference between the voltages detected at the other ends of the bifilar wires provides a measure of changing flux in the equilibrium-field coil. This difference can be used to detect faults in the coil in time to take action to protect the coil.
Graves, Tabitha A.; Royle, J. Andrew; Kendall, Katherine C.; Beier, Paul; Stetz, Jeffrey B.; Macleod, Amy C.
2012-01-01
Using multiple detection methods can increase the number, kind, and distribution of individuals sampled, which may increase accuracy and precision and reduce cost of population abundance estimates. However, when variables influencing abundance are of interest, if individuals detected via different methods are influenced by the landscape differently, separate analysis of multiple detection methods may be more appropriate. We evaluated the effects of combining two detection methods on the identification of variables important to local abundance using detections of grizzly bears with hair traps (systematic) and bear rubs (opportunistic). We used hierarchical abundance models (N-mixture models) with separate model components for each detection method. If both methods sample the same population, the use of either data set alone should (1) lead to the selection of the same variables as important and (2) provide similar estimates of relative local abundance. We hypothesized that the inclusion of 2 detection methods versus either method alone should (3) yield more support for variables identified in single method analyses (i.e. fewer variables and models with greater weight), and (4) improve precision of covariate estimates for variables selected in both separate and combined analyses because sample size is larger. As expected, joint analysis of both methods increased precision as well as certainty in variable and model selection. However, the single-method analyses identified different variables and the resulting predicted abundances had different spatial distributions. We recommend comparing single-method and jointly modeled results to identify the presence of individual heterogeneity between detection methods in N-mixture models, along with consideration of detection probabilities, correlations among variables, and tolerance to risk of failing to identify variables important to a subset of the population. The benefits of increased precision should be weighed against those risks. The analysis framework presented here will be useful for other species exhibiting heterogeneity by detection method.
Costantini, Verónica P.; Azevedo, Ana C.; Li, Xin; Williams, Mike C.; Michel, Frederick C.; Saif, Linda J.
2007-01-01
Enteric pathogens in animal waste that is not properly processed can contaminate the environment and food. The persistence of pathogens in animal waste depends upon the waste treatment technology, but little is known about persistence of porcine viruses. Our objectives were to characterize the porcine enteric viruses (porcine noroviruses [PoNoVs], porcine sapoviruses [PoSaVs], rotavirus A [RV-A], RV-B, and RV-C) in fresh feces or manure and to evaluate the effects of different candidate environmentally superior technologies (ESTs) for animal waste treatment on the detection of these viruses. Untreated manure and samples collected at different stages during and after treatment were obtained from swine farms that used conventional waste management (CWM) and five different candidate ESTs. The RNA from porcine enteric viruses was detected by reverse transcription-PCR and/or seminested PCR; PoSaV and RV-A were also detected by enzyme-linked immunosorbent assay. Cell culture immunofluorescence (CCIF) and experimental inoculation of gnotobiotic (Gn) pigs were used to determine RV-A/C infectivity in posttreatment samples. The PoSaV and RV-A were detected in pretreatment samples from each farm, whereas PoNoV and RV-C were detected in pretreatment feces from three of five and four of five farms using the candidate ESTs, respectively. After treatment, PoSaV RNA was detected only in the samples from the farm using CWM and not from the farms using the candidate ESTs. RV-A and RV-C RNAs were detected in four of five and three of four candidate ESTs, respectively, after treatment, but infectious particles were not detected by CCIF, nor were clinical signs or seroconversion detected in inoculated Gn pigs. These results indicate that only RV-A/C RNA, but no viral infectivity, was detected after treatment. Our findings address a public health concern regarding environmental quality surrounding swine production units. PMID:17601821
Costantini, Verónica P; Azevedo, Ana C; Li, Xin; Williams, Mike C; Michel, Frederick C; Saif, Linda J
2007-08-01
Enteric pathogens in animal waste that is not properly processed can contaminate the environment and food. The persistence of pathogens in animal waste depends upon the waste treatment technology, but little is known about persistence of porcine viruses. Our objectives were to characterize the porcine enteric viruses (porcine noroviruses [PoNoVs], porcine sapoviruses [PoSaVs], rotavirus A [RV-A], RV-B, and RV-C) in fresh feces or manure and to evaluate the effects of different candidate environmentally superior technologies (ESTs) for animal waste treatment on the detection of these viruses. Untreated manure and samples collected at different stages during and after treatment were obtained from swine farms that used conventional waste management (CWM) and five different candidate ESTs. The RNA from porcine enteric viruses was detected by reverse transcription-PCR and/or seminested PCR; PoSaV and RV-A were also detected by enzyme-linked immunosorbent assay. Cell culture immunofluorescence (CCIF) and experimental inoculation of gnotobiotic (Gn) pigs were used to determine RV-A/C infectivity in posttreatment samples. The PoSaV and RV-A were detected in pretreatment samples from each farm, whereas PoNoV and RV-C were detected in pretreatment feces from three of five and four of five farms using the candidate ESTs, respectively. After treatment, PoSaV RNA was detected only in the samples from the farm using CWM and not from the farms using the candidate ESTs. RV-A and RV-C RNAs were detected in four of five and three of four candidate ESTs, respectively, after treatment, but infectious particles were not detected by CCIF, nor were clinical signs or seroconversion detected in inoculated Gn pigs. These results indicate that only RV-A/C RNA, but no viral infectivity, was detected after treatment. Our findings address a public health concern regarding environmental quality surrounding swine production units.
The Influence of Assay Design, Blinding, and Gymnema sylvestre on Sucrose Detection by Humans.
Aleman, Max G; Marconi, Lauren J; Nguyen, Nam H; Park, Jae M; Patino, Maria M; Wang, Yuchi; Watkins, Celeste S; Shelley, Chris
2016-01-01
The detection and grading of tastes corresponding to different taste modalities can be tested in engaging laboratory sessions using students themselves as test subjects. This article describes a series of experiments in which data pertaining to the detection of salty and sweet tastes are obtained, and the ability of the herb Gymnema sylvestre to disrupt the detection of sucrose is quantified. The effects of blinding and different assay designs on EC50 estimation are also investigated. The data obtained allow for substantial data analysis, including non-linear regression using fixed and free parameters to quantify dose-response relationships, and the use of often under-utilized permutation tests to determine significant differences when the underlying data display heteroscedasticity.
The Influence of Assay Design, Blinding, and Gymnema sylvestre on Sucrose Detection by Humans
Aleman, Max G.; Marconi, Lauren J.; Nguyen, Nam H.; Park, Jae M.; Patino, Maria M.; Wang, Yuchi; Watkins, Celeste S.; Shelley, Chris
2016-01-01
The detection and grading of tastes corresponding to different taste modalities can be tested in engaging laboratory sessions using students themselves as test subjects. This article describes a series of experiments in which data pertaining to the detection of salty and sweet tastes are obtained, and the ability of the herb Gymnema sylvestre to disrupt the detection of sucrose is quantified. The effects of blinding and different assay designs on EC50 estimation are also investigated. The data obtained allow for substantial data analysis, including non-linear regression using fixed and free parameters to quantify dose-response relationships, and the use of often under-utilized permutation tests to determine significant differences when the underlying data display heteroscedasticity. PMID:27980466
NASA Astrophysics Data System (ADS)
Leng, Yumin; He, Junbao; Li, Bo; Xing, Xiaojing; Guo, Yongming; Ye, Liqun; Lu, Zhiwen
2017-09-01
The different sized and shaped Au NPs have intrigued considerable attention, because they possess different surface plasma resonance (SPR) absorption bands and thus result in many colorimetric Au NP-based detection applications. In this article, four different sized and shaped Au NPs of nanodots/rods were prepared and characterized. The as-prepared Au NPs were modified by the negatively charged anions of [SCH2CO2]2- to investigate both the size and shape effects of modified Au NPs on colorimetric detection of Co2+ and the corresponding SPR absorption properties. The different-shaped Au NPs possess different SPR absorption properties. The Au nanorods appeared to be colorimetric sensitive for Co2+ sensing.
NASA Astrophysics Data System (ADS)
Aijazi, A. K.; Malaterre, L.; Tazir, M. L.; Trassoudaine, L.; Checchin, P.
2016-06-01
This work presents a new method that automatically detects and analyzes surface defects such as corrosion spots of different shapes and sizes, on large ship hulls. In the proposed method several scans from different positions and viewing angles around the ship are registered together to form a complete 3D point cloud. The R, G, B values associated with each scan, obtained with the help of an integrated camera are converted into HSV space to separate out the illumination invariant color component from the intensity. Using this color component, different surface defects such as corrosion spots of different shapes and sizes are automatically detected, within a selected zone, using two different methods depending upon the level of corrosion/defects. The first method relies on a histogram based distribution whereas the second on adaptive thresholds. The detected corrosion spots are then analyzed and quantified to help better plan and estimate the cost of repair and maintenance. Results are evaluated on real data using different standard evaluation metrics to demonstrate the efficacy as well as the technical strength of the proposed method.
Janse, Ingmar; Bok, Jasper M.; Hamidjaja, Raditijo A.; Hodemaekers, Hennie M.; van Rotterdam, Bart J.
2012-01-01
Microarrays provide a powerful analytical tool for the simultaneous detection of multiple pathogens. We developed diagnostic suspension microarrays for sensitive and specific detection of the biothreat pathogens Bacillus anthracis, Yersinia pestis, Francisella tularensis and Coxiella burnetii. Two assay chemistries for amplification and labeling were developed, one method using direct hybridization and the other using target-specific primer extension, combined with hybridization to universal arrays. Asymmetric PCR products for both assay chemistries were produced by using a multiplex asymmetric PCR amplifying 16 DNA signatures (16-plex). The performances of both assay chemistries were compared and their advantages and disadvantages are discussed. The developed microarrays detected multiple signature sequences and an internal control which made it possible to confidently identify the targeted pathogens and assess their virulence potential. The microarrays were highly specific and detected various strains of the targeted pathogens. Detection limits for the different pathogen signatures were similar or slightly higher compared to real-time PCR. Probit analysis showed that even a few genomic copies could be detected with 95% confidence. The microarrays detected DNA from different pathogens mixed in different ratios and from spiked or naturally contaminated samples. The assays that were developed have a potential for application in surveillance and diagnostics. PMID:22355407
Janse, Ingmar; Bok, Jasper M; Hamidjaja, Raditijo A; Hodemaekers, Hennie M; van Rotterdam, Bart J
2012-01-01
Microarrays provide a powerful analytical tool for the simultaneous detection of multiple pathogens. We developed diagnostic suspension microarrays for sensitive and specific detection of the biothreat pathogens Bacillus anthracis, Yersinia pestis, Francisella tularensis and Coxiella burnetii. Two assay chemistries for amplification and labeling were developed, one method using direct hybridization and the other using target-specific primer extension, combined with hybridization to universal arrays. Asymmetric PCR products for both assay chemistries were produced by using a multiplex asymmetric PCR amplifying 16 DNA signatures (16-plex). The performances of both assay chemistries were compared and their advantages and disadvantages are discussed. The developed microarrays detected multiple signature sequences and an internal control which made it possible to confidently identify the targeted pathogens and assess their virulence potential. The microarrays were highly specific and detected various strains of the targeted pathogens. Detection limits for the different pathogen signatures were similar or slightly higher compared to real-time PCR. Probit analysis showed that even a few genomic copies could be detected with 95% confidence. The microarrays detected DNA from different pathogens mixed in different ratios and from spiked or naturally contaminated samples. The assays that were developed have a potential for application in surveillance and diagnostics.
Detecting dominant motion patterns in crowds of pedestrians
NASA Astrophysics Data System (ADS)
Saqib, Muhammad; Khan, Sultan Daud; Blumenstein, Michael
2017-02-01
As the population of the world increases, urbanization generates crowding situations which poses challenges to public safety and security. Manual analysis of crowded situations is a tedious job and usually prone to errors. In this paper, we propose a novel technique of crowd analysis, the aim of which is to detect different dominant motion patterns in real-time videos. A motion field is generated by computing the dense optical flow. The motion field is then divided into blocks. For each block, we adopt an Intra-clustering algorithm for detecting different flows within the block. Later on, we employ Inter-clustering for clustering the flow vectors among different blocks. We evaluate the performance of our approach on different real-time videos. The experimental results show that our proposed method is capable of detecting distinct motion patterns in crowded videos. Moreover, our algorithm outperforms state-of-the-art methods.
NASA Astrophysics Data System (ADS)
Zhang, He; Niu, Yanxiong; Zhang, Hao
2017-12-01
Small target detection is a significant subject in infrared search and track and other photoelectric imaging systems. The small target is imaged under complex conditions, which contains clouds, horizon and bright part. In this paper, a novel small target detection method is proposed based on difference accumulation, clustering and Gaussian curvature. Difference accumulation varies from regions. Therefore, after obtaining difference accumulations, clustering is applied to determine whether the pixel belongs to the heterogeneous region, and eliminate heterogeneous region. Then Gaussian curvature is used to separate target from the homogeneous region. Experiments are conducted for verification, along with comparisons to several other methods. The experimental results demonstrate that our method has an advantage of 1-2 orders of magnitude on SCRG and BSF than others. Given that the false alarm rate is 1, the detection probability can be approximately 0.9 by using proposed method.
Methods for gas detection using stationary hyperspectral imaging sensors
Conger, James L [San Ramon, CA; Henderson, John R [Castro Valley, CA
2012-04-24
According to one embodiment, a method comprises producing a first hyperspectral imaging (HSI) data cube of a location at a first time using data from a HSI sensor; producing a second HSI data cube of the same location at a second time using data from the HSI sensor; subtracting on a pixel-by-pixel basis the second HSI data cube from the first HSI data cube to produce a raw difference cube; calibrating the raw difference cube to produce a calibrated raw difference cube; selecting at least one desired spectral band based on a gas of interest; producing a detection image based on the at least one selected spectral band and the calibrated raw difference cube; examining the detection image to determine presence of the gas of interest; and outputting a result of the examination. Other methods, systems, and computer program products for detecting the presence of a gas are also described.
NASA Astrophysics Data System (ADS)
Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco
2008-08-01
The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.
Automatic rectum limit detection by anatomical markers correlation.
Namías, R; D'Amato, J P; del Fresno, M; Vénere, M
2014-06-01
Several diseases take place at the end of the digestive system. Many of them can be diagnosed by means of different medical imaging modalities together with computer aided detection (CAD) systems. These CAD systems mainly focus on the complete segmentation of the digestive tube. However, the detection of limits between different sections could provide important information to these systems. In this paper we present an automatic method for detecting the rectum and sigmoid colon limit using a novel global curvature analysis over the centerline of the segmented digestive tube in different imaging modalities. The results are compared with the gold standard rectum upper limit through a validation scheme comprising two different anatomical markers: the third sacral vertebra and the average rectum length. Experimental results in both magnetic resonance imaging (MRI) and computed tomography colonography (CTC) acquisitions show the efficacy of the proposed strategy in automatic detection of rectum limits. The method is intended for application to the rectum segmentation in MRI for geometrical modeling and as contextual information source in virtual colonoscopies and CAD systems. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez
2008-08-11
The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less
Systematic evaluation of deep learning based detection frameworks for aerial imagery
NASA Astrophysics Data System (ADS)
Sommer, Lars; Steinmann, Lucas; Schumann, Arne; Beyerer, Jürgen
2018-04-01
Object detection in aerial imagery is crucial for many applications in the civil and military domain. In recent years, deep learning based object detection frameworks significantly outperformed conventional approaches based on hand-crafted features on several datasets. However, these detection frameworks are generally designed and optimized for common benchmark datasets, which considerably differ from aerial imagery especially in object sizes. As already demonstrated for Faster R-CNN, several adaptations are necessary to account for these differences. In this work, we adapt several state-of-the-art detection frameworks including Faster R-CNN, R-FCN, and Single Shot MultiBox Detector (SSD) to aerial imagery. We discuss adaptations that mainly improve the detection accuracy of all frameworks in detail. As the output of deeper convolutional layers comprise more semantic information, these layers are generally used in detection frameworks as feature map to locate and classify objects. However, the resolution of these feature maps is insufficient for handling small object instances, which results in an inaccurate localization or incorrect classification of small objects. Furthermore, state-of-the-art detection frameworks perform bounding box regression to predict the exact object location. Therefore, so called anchor or default boxes are used as reference. We demonstrate how an appropriate choice of anchor box sizes can considerably improve detection performance. Furthermore, we evaluate the impact of the performed adaptations on two publicly available datasets to account for various ground sampling distances or differing backgrounds. The presented adaptations can be used as guideline for further datasets or detection frameworks.