Sample records for detecting significant differences

  1. Human papillomavirus detection with genotyping by the cobas and Aptima assays: Significant differences in HPV 16 detection?

    PubMed

    Chorny, Joseph A; Frye, Teresa C; Fisher, Beth L; Remmers, Carol L

    2018-03-23

    The primary high-risk human papillomavirus (hrHPV) assays in the United States are the cobas (Roche) and the Aptima (Hologic). The cobas assay detects hrHPV by DNA analysis while the Aptima detects messenger RNA (mRNA) oncogenic transcripts. As the Aptima assay identifies oncogenic expression, it should have a lower rate of hrHPV and genotype detection. The Kaiser Permanente Regional Reference Laboratory in Denver, Colorado changed its hrHPV assay from the cobas to the Aptima assay. The rates of hrHPV detection and genotyping were compared over successive six-month periods. The overall hrHPV detection rates by the two platforms were similar (9.5% versus 9.1%) and not statistically different. For genotyping, the HPV 16 rate by the cobas was 1.6% and by the Aptima it was 1.1%. These differences were statistically different with the Aptima detecting nearly one-third less HPV 16 infections. With the HPV 18 and HPV 18/45, there was a slightly higher detection rate of HPV 18/45 by the Aptima platform (0.5% versus 0.9%) and this was statistically significant. While HPV 16 represents a low percentage of hrHPV infections, it was detected significantly less by the Aptima assay compared to the cobas assay. This has been previously reported, although not highlighted. Given the test methodologies, one would expect the Aptima to detect less HPV 16. This difference appears to be mainly due to a significantly increased number of non-oncogenic HPV 16 infections detected by the cobas test as there were no differences in HPV 16 detection rates in the high-grade squamous intraepithelial lesions indicating that the two tests have similar sensitivities for oncogenic HPV 16. © 2018 Wiley Periodicals, Inc.

  2. [Comparative analysis of 6 kinds of bacteria in the subgingival plaque in different types of patients with periodontal diseases].

    PubMed

    Ma, Ying-ying; Zhang, Tao-wen; Jiang, Yu-xi; Liu, Shu-tai

    2015-10-01

    To detect the existence of Aa,Pg,Tf,Cr,Ec and Pn in the subgingival plaque, and determine their relationships among different types of periodontal diseases. Dental plaques from 120 subjects were sampled, including 40 volunteers with health periodontal status(Group A) , forty patients with dental plaque-induced gingival diseases(Group B) and 40 patients with moderate or severe chronic periodontitis (Group C) . These samples were detected based on bacterial composition using the terminal restriction fragment length polymorphism of 16S rRNA genes by multiple-polymerase chain reaction. The data was analysed with SPSS 13.0 software package for Chi-square test. The detection rate of Pn, Cr and Pg had significant differences between group A and B. The detection rate of Ec, Cr, Pg, Aa and Tf had significant differences between group C and B. The detection rate of Ec, Pn, Cr, Pg, Aa and Tf had significant differences between group A and C. The rate of Ec, Pn, Cr, Pg and Tf detected in moderate or patients with moderate or severe chronic periodontitis are significantly higher than that in healthy subjects, indicating that these bacteria have certain correlation with chronic periodontitis. The rate of Ec, Cr, Pg and Tf detected in severe chronic periodontitis are significantly higher than that in dental-induced gingivitis, suggesting their close relationship with the progress of periodontal disease.

  3. Dangerous gas detection based on infrared video

    NASA Astrophysics Data System (ADS)

    Ding, Kang; Hong, Hanyu; Huang, Likun

    2018-03-01

    As the gas leak infrared imaging detection technology has significant advantages of high efficiency and remote imaging detection, in order to enhance the detail perception of observers and equivalently improve the detection limit, we propose a new type of gas leak infrared image detection method, which combines background difference methods and multi-frame interval difference method. Compared to the traditional frame methods, the multi-frame interval difference method we proposed can extract a more complete target image. By fusing the background difference image and the multi-frame interval difference image, we can accumulate the information of infrared target image of the gas leak in many aspect. The experiment demonstrate that the completeness of the gas leakage trace information is enhanced significantly, and the real-time detection effect can be achieved.

  4. Salt taste after bariatric surgery and weight loss in obese persons

    PubMed Central

    Maedge, Julia; Lam, Linda; Blasche, Gerhard; Shakeri-Leidenmühler, Soheila; Kundi, Michael; Ludvik, Bernhard; Langer, Felix B.; Prager, Gerhard; Schindler, Karin; Dürrschmid, Klaus

    2016-01-01

    Background. Little is known about the perception of salty taste in obese patients, especially after bariatric surgery. Therefore, the aim of this study was to analyse possible differences in salt detection thresholds and preferences for foods differing in salt content in obese persons before and after bariatric surgery with weight loss compared to non-obese individuals. Methods. Sodium chloride detection thresholds and liking for cream soups with different salt concentrations were studied with established tests. Moreover, a brief salt food questionnaire was assessed to identify the usage and awareness of salt in food. Results. The results showed similar mean sodium chloride detection thresholds between non-obese and obese participants. After bariatric surgery a non-significant increase in the salt detection threshold was observed in the obese patients (mean ± SD: 0.44 ± 0.24 g NaCl/L before OP vs. 0.64 ± 0.47 g NaCl/L after OP, p = 0.069). Cream soup liking between controls and obese patients were not significantly different. However, significant sex specific differences were detected with the tested women not liking the soups (p < 0.001). Results from the food questionnaire were similar between the groups. Conclusion. No differences between non-obese persons and obese patients were shown regarding the salt detection threshold. However, due to highly significant differences in soup liking, sex should be taken into consideration when conducting similar sensory studies. PMID:27330856

  5. Anticoagulant rodenticides in red-tailed hawks, Buteo jamaicensis, and great horned owls, Bubo virginianus, from New Jersey, USA, 2008-2010.

    PubMed

    Stansley, William; Cummings, Margaret; Vudathala, Daljit; Murphy, Lisa A

    2014-01-01

    Liver samples from red-tailed hawks (Buteo jamaicensis) and great horned owls (Bubo virginianus) were analyzed for anticoagulant rodenticides. Residues of one or more second generation anticoagulant rodenticides (SGARs) were detected in 81 % of red-tailed hawks and 82 % of great horned owls. The most frequently detected SGAR was brodifacoum, which was detected in 76 % of red-tailed hawks and 73 % of great horned owls. Bromadiolone was detected in 20 % of red-tailed hawks and 27 % of great horned owls. Difenacoum was detected in one great horned owl. No other ARs were detected. There were no significant differences between species in the frequency of detection or concentration of brodifacoum or bromadiolone. There was a marginally significant difference (p = 0.0497) between total SGAR residues in red-tailed hawks (0.117 mg/kg) and great horned owls (0.070 mg/kg). There were no seasonal differences in the frequency of detection or concentration of brodifacoum in red-tailed hawks. The data suggest that SGARs pose a significant risk of poisoning to predatory birds in New Jersey.

  6. The effect of length and starting year on trend analyses of temperatures in Spanish mainland (1951-2010). Seasonal analyses: Spring (III)

    NASA Astrophysics Data System (ADS)

    Salinas Solé, Celia; Peña Angulo, Dhais; Gonzalez Hidalgo, Jose Carlos; Brunetti, Michele

    2017-04-01

    In this poster we applied the moving window approach (see Poster I of this collection) to analyze trends of spring and its corresponding months (March, April, May) temperature mean values of maximum (Tmax) and minimum (Tmin) in Spanish mainland to detect the effects of length period and starting year. Monthly series belong to Monthly Temperature dataset of Spanish mainland (MOTEDAS). Database contains in its grid format of 5236 pixels of monthly series (10x10 km). The threshold used in spatial analyses considers 20% of land under significant trend (p<0.05). The most striking results are as follow: • Seasonal Tmax shows that global trend was positive and significant until the mid 80's with higher values than 75% from between 1954-2010 to 1979-2010, being reduced after to the north region. So, from 1985-2010 no significant trend have been detected. Monthly analyses show differences. March trend is not significant (<20% of area) since 1974-2010, while significant trend in April and May varies between 1961-2010/1979-2010 and 1965-2010/1980-2010 respectively, clearly located in northern midland and Mediterranean coastland. • Spring Tmin trend analyses is significantly (>20%) during all temporal windows, notwithstanding NW do not show global significant trend, and in the most recent temporal windows only affect significantly SE. Monthly analyses also differ. Not significant trend is detected in March from 1979-2010, and from 1985-2010 in May, being April the month in any temporal windows with more than 20% of land affected by significant trend. • Spatial differences are detected between windows (South-North in March, East-West in April-May. We can conclude Tmax trend varies accordingly temporal windows dramatically in spring and no significance has been detected in the recent decades. Northern areas and Mediterranean coastland seems to be the most affected. Monthy Tmax trend spatial analyses confirm the heterogeneity of diurnal temperatures; different spatial gradients in windows have been detected between months. Seasonal Tmin show a more global temporal pattern. Spatial gradients of significance between months have been detected, in some sense contraries to the observed in Tmax.

  7. The Ability of Different Imputation Methods to Preserve the Significant Genes and Pathways in Cancer.

    PubMed

    Aghdam, Rosa; Baghfalaki, Taban; Khosravi, Pegah; Saberi Ansari, Elnaz

    2017-12-01

    Deciphering important genes and pathways from incomplete gene expression data could facilitate a better understanding of cancer. Different imputation methods can be applied to estimate the missing values. In our study, we evaluated various imputation methods for their performance in preserving significant genes and pathways. In the first step, 5% genes are considered in random for two types of ignorable and non-ignorable missingness mechanisms with various missing rates. Next, 10 well-known imputation methods were applied to the complete datasets. The significance analysis of microarrays (SAM) method was applied to detect the significant genes in rectal and lung cancers to showcase the utility of imputation approaches in preserving significant genes. To determine the impact of different imputation methods on the identification of important genes, the chi-squared test was used to compare the proportions of overlaps between significant genes detected from original data and those detected from the imputed datasets. Additionally, the significant genes are tested for their enrichment in important pathways, using the ConsensusPathDB. Our results showed that almost all the significant genes and pathways of the original dataset can be detected in all imputed datasets, indicating that there is no significant difference in the performance of various imputation methods tested. The source code and selected datasets are available on http://profiles.bs.ipm.ir/softwares/imputation_methods/. Copyright © 2017. Production and hosting by Elsevier B.V.

  8. Got power? A systematic review of sample size adequacy in health professions education research.

    PubMed

    Cook, David A; Hatala, Rose

    2015-03-01

    Many education research studies employ small samples, which in turn lowers statistical power. We re-analyzed the results of a meta-analysis of simulation-based education to determine study power across a range of effect sizes, and the smallest effect that could be plausibly excluded. We systematically searched multiple databases through May 2011, and included all studies evaluating simulation-based education for health professionals in comparison with no intervention or another simulation intervention. Reviewers working in duplicate abstracted information to calculate standardized mean differences (SMD's). We included 897 original research studies. Among the 627 no-intervention-comparison studies the median sample size was 25. Only two studies (0.3%) had ≥80% power to detect a small difference (SMD > 0.2 standard deviations) and 136 (22%) had power to detect a large difference (SMD > 0.8). 110 no-intervention-comparison studies failed to find a statistically significant difference, but none excluded a small difference and only 47 (43%) excluded a large difference. Among 297 studies comparing alternate simulation approaches the median sample size was 30. Only one study (0.3%) had ≥80% power to detect a small difference and 79 (27%) had power to detect a large difference. Of the 128 studies that did not detect a statistically significant effect, 4 (3%) excluded a small difference and 91 (71%) excluded a large difference. In conclusion, most education research studies are powered only to detect effects of large magnitude. For most studies that do not reach statistical significance, the possibility of large and important differences still exists.

  9. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco

    2008-08-01

    The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

  10. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez

    2008-08-11

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less

  11. Age-related differences in gap detection: effects of task difficulty and cognitive ability.

    PubMed

    Harris, Kelly C; Eckert, Mark A; Ahlstrom, Jayne B; Dubno, Judy R

    2010-06-01

    Differences in gap detection for younger and older adults have been shown to vary with the complexity of the task or stimuli, but the factors that contribute to these differences remain unknown. To address this question, we examined the extent to which age-related differences in processing speed and workload predicted age-related differences in gap detection. Gap detection thresholds were measured for 10 younger and 11 older adults in two conditions that varied in task complexity but used identical stimuli: (1) gap location fixed at the beginning, middle, or end of a noise burst and (2) gap location varied randomly from trial to trial from the beginning, middle, or end of the noise. We hypothesized that gap location uncertainty would place increased demands on cognitive and attentional resources and result in significantly higher gap detection thresholds for older but not younger adults. Overall, gap detection thresholds were lower for the middle location as compared to beginning and end locations and were lower for the fixed than the random condition. In general, larger age-related differences in gap detection were observed for more challenging conditions. That is, gap detection thresholds for older adults were significantly larger for the random condition than for the fixed condition when the gap was at the beginning and end locations but not the middle. In contrast, gap detection thresholds for younger adults were not significantly different for the random and fixed condition at any location. Subjective ratings of workload indicated that older adults found the gap detection task more mentally demanding than younger adults. Consistent with these findings, results of the Purdue Pegboard and Connections tests revealed age-related slowing of processing speed. Moreover, age group differences in workload and processing speed predicted gap detection in younger and older adults when gap location varied from trial to trial; these associations were not observed when gap location remained constant across trials. Taken together, these results suggest that age-related differences in complex measures of auditory temporal processing may be explained, in part, by age-related deficits in processing speed and attention. Copyright 2009 Elsevier B.V. All rights reserved.

  12. Age-related differences in gap detection: Effects of task difficulty and cognitive ability

    PubMed Central

    Harris, Kelly C.; Eckert, Mark A.; Ahlstrom, Jayne B.; Dubno, Judy R.

    2009-01-01

    Differences in gap detection for younger and older adults have been shown to vary with the complexity of the task or stimuli, but the factors that contribute to these differences remain unknown. To address this question, we examined the extent to which age-related differences in processing speed and workload predicted age-related differences in gap detection. Gap detection thresholds were measured for 10 younger and 11 older adults in two conditions that varied in task complexity but used identical stimuli: (1) gap location fixed at the beginning, middle, or end of a noise burst and (2) gap location varied randomly from trial to trial from the beginning, middle, or end of the noise. We hypothesized that gap location uncertainty would place increased demands on cognitive and attentional resources and result in significantly higher gap detection thresholds for older but not younger adults. Overall, gap detection thresholds were lower for the middle location as compared to beginning and end locations and were lower for the fixed than the random condition. In general, larger age-related differences in gap detection were observed for more challenging conditions. That is, gap detection thresholds for older adults were significantly larger for the random condition than for the fixed condition when the gap was at the beginning and end locations but not the middle. In contrast, gap detection thresholds for younger adults were not significantly different for the random and fixed condition at any location. Subjective ratings of workload indicated that older adults found the gap-detection task more mentally demanding than younger adults. Consistent with these findings, results of the Purdue Pegboard and Connections tests revealed age-related slowing of processing speed. Moreover, age group differences in workload and processing speed predicted gap detection in younger and older adults when gap location varied from trial to trial; these associations were not observed when gap location remained constant across trials. Taken together, these results suggest that age-related differences in complex measures of auditory temporal processing may be explained, in part, by age-related deficits in processing speed and attention. PMID:19800958

  13. Detection of Viral and Bacterial Pathogens in Hospitalized Children With Acute Respiratory Illnesses, Chongqing, 2009–2013

    PubMed Central

    Wei, Lan; Liu, Wei; Zhang, Xiao-Ai; Liu, En-Mei; Wo, Yin; Cowling, Benjamin J.; Cao, Wu-Chun

    2015-01-01

    Abstract Acute respiratory infections (ARIs) cause large disease burden each year. The codetection of viral and bacterial pathogens is quite common; however, the significance for clinical severity remains controversial. We aimed to identify viruses and bacteria in hospitalized children with ARI and the impact of mixed detections. Hospitalized children with ARI aged ≤16 were recruited from 2009 to 2013 at the Children's Hospital of Chongqing Medical University, Chongqing, China. Nasopharyngeal aspirates (NPAs) were collected for detection of common respiratory viruses by reverse transcription polymerase chain reaction (RT-PCR) or PCR. Bacteria were isolated from NPAs by routine culture methods. Detection and codetection frequencies and clinical features and severity were compared. Of the 3181 hospitalized children, 2375 (74.7%) were detected with ≥1 virus and 707 (22.2%) with ≥1 bacteria, 901 (28.3%) with ≥2 viruses, 57 (1.8%) with ≥2 bacteria, and 542 (17.0%) with both virus and bacteria. The most frequently detected were Streptococcus pneumoniae, respiratory syncytial virus, parainfluenza virus, and influenza virus. Clinical characteristics were similar among different pathogen infections for older group (≥6 years old), with some significant difference for the younger. Cases with any codetection were more likely to present with fever; those with ≥2 virus detections had higher prevalence of cough; cases with virus and bacteria codetection were more likely to have cough and sputum. No significant difference in the risk of pneumonia, severe pneumonia, and intensive care unit admission were found for any codetection than monodetection. There was a high codetection rate of common respiratory pathogens among hospitalized pediatric ARI cases, with fever as a significant predictor. Cases with codetection showed no significant difference in severity than those with single pathogens. PMID:25906103

  14. Three-dimensional images contribute to the diagnosis of mucous retention cyst in maxillary sinus.

    PubMed

    Donizeth-Rodrigues, Cleomar; Fonseca-Da Silveira, Márcia; Gonçalves-De Alencar, Ana-Helena; Garcia-Santos-Silva, Maria-Alves; Francisco-De-Mendonça, Elismauro; Estrela, Carlos

    2013-01-01

    To evaluate the detection of mucous retention cyst of maxillary sinus (MRCMS) using panoramic radiography and cone beam computed tomography (CBCT). A digital database with 6,000 panoramic radiographs was reviewed for MRCMS. Suggestive images of MRCMS were detected on 185 radiographs, and patients were located and invited to return for follow-up. Thirty patients returned, and control panoramic radiographs were obtained 6 to 46 months after the initial radiograph. When MRCMS was found on control radiographs, CBCT scans were obtained. Cysts were measured and compared on radiographs and scans. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical analysis. The level of significance was set at 5%. There were statistically significant differences between the two methods (p<0.05): 23 MRCMS detected on panoramic radiographs were confirmed by CBCT, but 5 MRCMS detected on CBCT images had not been identified by panoramic radiography. Eight MRCMS detected on control radiographs were not confirmed by CBCT. MRCMS size differences from initial to control panoramic radiographs and CBCT scans were not statistically significant (p= 0.617 and p= 0.626). The correlation between time and MRCMS size differences was not significant (r = -0.16, p = 0.381). CBCT scanning detect MRCMS more accurately than panoramic radiography.

  15. Improved flaw detection and characterization with difference thermography

    NASA Astrophysics Data System (ADS)

    Winfree, William P.; Zalameda, Joseph N.; Howell, Patricia A.

    2011-05-01

    Flaw detection and characterization with thermographic techniques in graphite polymer composites is often limited by localized variations in the thermographic response. Variations in properties such as acceptable porosity, variations in fiber volume content and surface polymer thickness result in variations in the thermal response that in general cause significant variations in the initial thermal response. These variations result in a noise floor that increases the difficulty of detecting and characterizing deeper flaws. The paper investigates comparing thermographic responses taken before and after a change in state in a composite to improve the detection of subsurface flaws. A method is presented for registration of the responses before finding the difference. A significant improvement in the detectability is achieved by comparing the differences in response. Examples of changes in state due to application of a load and impact are presented.

  16. Improved Flaw Detection and Characterization with Difference Thermography

    NASA Technical Reports Server (NTRS)

    Winfree, William P.; Zalameda, Joseph N.; Howell, Patricia A.

    2011-01-01

    Flaw detection and characterization with thermographic techniques in graphite polymer composites is often limited by localized variations in the thermographic response. Variations in properties such as acceptable porosity, variations in fiber volume content and surface polymer thickness result in variations in the thermal response that in general cause significant variations in the initial thermal response. These variations result in a noise floor that increases the difficulty of detecting and characterizing deeper flaws. The paper investigates comparing thermographic responses taken before and after a change in state in a composite to improve the detection of subsurface flaws. A method is presented for registration of the responses before finding the difference. A significant improvement in the detectability is achieved by comparing the differences in response. Examples of changes in state due to application of a load and impact are presented.

  17. Strategies for Testing Statistical and Practical Significance in Detecting DIF with Logistic Regression Models

    ERIC Educational Resources Information Center

    Fidalgo, Angel M.; Alavi, Seyed Mohammad; Amirian, Seyed Mohammad Reza

    2014-01-01

    This study examines three controversial aspects in differential item functioning (DIF) detection by logistic regression (LR) models: first, the relative effectiveness of different analytical strategies for detecting DIF; second, the suitability of the Wald statistic for determining the statistical significance of the parameters of interest; and…

  18. Effect of Age and Glaucoma on the Detection of Darks and Lights

    PubMed Central

    Zhao, Linxi; Sendek, Caroline; Davoodnia, Vandad; Lashgari, Reza; Dul, Mitchell W.; Zaidi, Qasim; Alonso, Jose-Manuel

    2015-01-01

    Purpose We have shown previously that normal observers detect dark targets faster and more accurately than light targets, when presented in noisy backgrounds. We investigated how these differences in detection time and accuracy are affected by age and ganglion cell pathology associated with glaucoma. Methods We asked 21 glaucoma patients, 21 age-similar controls, and 5 young control observers to report as fast as possible the number of 1 to 3 light or dark targets. The targets were positioned at random in a binary noise background, within the central 30° of the visual field. Results We replicate previous findings that darks are detected faster and more accurately than lights. We extend these findings by demonstrating that differences in detection of darks and lights are found reliably across different ages and in observers with glaucoma. We show that differences in detection time increase at a rate of approximately 55 msec/dB at early stages of glaucoma and then remain constant at later stages at approximately 800 msec. In normal subjects, differences in detection time increase with age at a rate of approximately 8 msec/y. We also demonstrate that the accuracy to detect lights and darks is significantly correlated with the severity of glaucoma and that the mean detection time is significantly longer for subjects with glaucoma than age-similar controls. Conclusions We conclude that differences in detection of darks and lights can be demonstrated over a wide range of ages, and asymmetries in dark/light detection increase with age and early stages of glaucoma. PMID:26513506

  19. Effect of Age and Glaucoma on the Detection of Darks and Lights.

    PubMed

    Zhao, Linxi; Sendek, Caroline; Davoodnia, Vandad; Lashgari, Reza; Dul, Mitchell W; Zaidi, Qasim; Alonso, Jose-Manuel

    2015-10-01

    We have shown previously that normal observers detect dark targets faster and more accurately than light targets, when presented in noisy backgrounds. We investigated how these differences in detection time and accuracy are affected by age and ganglion cell pathology associated with glaucoma. We asked 21 glaucoma patients, 21 age-similar controls, and 5 young control observers to report as fast as possible the number of 1 to 3 light or dark targets. The targets were positioned at random in a binary noise background, within the central 30° of the visual field. We replicate previous findings that darks are detected faster and more accurately than lights. We extend these findings by demonstrating that differences in detection of darks and lights are found reliably across different ages and in observers with glaucoma. We show that differences in detection time increase at a rate of approximately 55 msec/dB at early stages of glaucoma and then remain constant at later stages at approximately 800 msec. In normal subjects, differences in detection time increase with age at a rate of approximately 8 msec/y. We also demonstrate that the accuracy to detect lights and darks is significantly correlated with the severity of glaucoma and that the mean detection time is significantly longer for subjects with glaucoma than age-similar controls. We conclude that differences in detection of darks and lights can be demonstrated over a wide range of ages, and asymmetries in dark/light detection increase with age and early stages of glaucoma.

  20. Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test objects used in television fluoroscopy.

    PubMed

    Launders, J H; McArdle, S; Workman, A; Cowen, A R

    1995-01-01

    The significance of varying the viewing conditions that may affect the perceived threshold contrast of X-ray television fluoroscopy systems has been investigated. Factors investigated include the ambient room lighting and the viewing distance. The purpose of this study is to find the optimum viewing protocol with which to measure the threshold detection index. This is a particular problem when trying to compare the image quality of television fluoroscopy systems in different input field sizes. The results show that the viewing distance makes a significant difference to the perceived threshold contrast, whereas the ambient light conditions make no significant difference. Experienced observers were found to be capable of finding the optimum viewing distance for detecting details of each size, in effect using a flexible viewing distance. This allows the results from different field sizes to be normalized to account for both the magnification and the entrance air kerma rate differences, which in turn allow for a direct comparison of performance in different field sizes.

  1. Soil carbon inventories under a bioenergy crop (switchgrass): Measurement limitations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garten, C.T. Jr.; Wullschleger, S.D.

    Approximately 5 yr after planting, coarse root carbon (C) and soil organic C (SOC) inventories were compared under different types of plant cover at four switchgrass (Panicum virgatum L.) production field trials in the southeastern USA. There was significantly more coarse root C under switchgrass (Alamo variety) and forest cover than tall fescue (Festuca arundinacea Schreb.), corn (Zea mays L.), or native pastures of mixed grasses. Inventories of SOC under switchgrass were not significantly greater than SOC inventories under other plant covers. At some locations the statistical power associated with ANOVA of SOC inventories was low, which raised questions aboutmore » whether differences in SOC could be detected statistically. A minimum detectable difference (MDD) for SOC inventories was calculated. The MDD is the smallest detectable difference between treatment means once the variation, significance level, statistical power, and sample size are specified. The analysis indicated that a difference of {approx}50 mg SOC/cm{sup 2} or 5 Mg SOC/ha, which is {approx}10 to 15% of existing SOC, could be detected with reasonable sample sizes and good statistical power. The smallest difference in SOC inventories that can be detected, and only with exceedingly large sample sizes, is {approx}2 to 3%. These measurement limitations have implications for monitoring and verification of proposals to ameliorate increasing global atmospheric CO{sub 2} concentrations by sequestering C in soils.« less

  2. Detection of circulating tumor cells using oHSV1-hTERT-GFP in lung cancer.

    PubMed

    Gao, Hongjun; Liu, Wenjing; Yang, Shaoxing; Zhang, Wen; Li, Xiaoyan; Qin, Haifeng; Wang, Weixia; Zhao, Changyun

    2018-01-01

    This study was conducted to evaluate the clinical utility of the oHSV1-hTERT-GFP circulating tumor cell (CTC) detection method in the peripheral blood of patients with lung cancer by comparing its sensitivity to the CellSearch CTC detection method. The oHSV1-hTERT-GFP and CellSearch CTC detection methods were compared using peripheral blood samples of patients pathologically diagnosed with lung cancer. A total of 240 patients with lung cancer were recruited, including 89 patients who were newly diagnosed and 151 patients who had previously received treatment. Sixty-six newly diagnosed patients were evaluated using both methods. The CTC detection rates were 71.2% and 33.3% using the oHSV1-hTERT-GFP and CellSearch methods, respectively; this difference was statistically significant (P = 0.000). Among the entire cohort (n = 240), the CTC detection rate using the oHSV1-hTERT-GFP method was 76.3%, with a CTC count of 0-81. The CTC detection rates were 76.7%, 68.9%, and 76.3% in patients with squamous cell carcinoma, adenocarcinoma, and small cell lung cancer, respectively. There was no statistically significant difference in the CTC detection rates between these different pathological subtypes (P = 0.738). The CTC detection rates of 79.8% and 74.4% in patients with stage I-III and IV lung cancer, respectively, were not significantly different (P = 0.427). The oHSV1-hTERT-GFP method is highly effective for detecting CTCs in patients with lung cancer, independent of pathological type and disease stage, and is ideal for large-scale clinical applications. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  3. Luminance level of a monitor: influence on detectability and detection rate of breast cancer in 2D mammography

    NASA Astrophysics Data System (ADS)

    Bemelmans, Frédéric; Rashidnasab, Alaleh; Chesterman, Frédérique; Kimpe, Tom; Bosmans, Hilde

    2016-03-01

    Purpose: To evaluate lesion detectability and reading time as a function of luminance level of the monitor. Material and Methods: 3D mass models and microcalcification clusters were simulated into ROIs of for processing mammograms. Randomly selected ROIs were subdivided in three groups according to their background glandularity: high (>30%), medium (15-30%) and low (<15%). 6 non-spiculated masses (9 - 11mm), 6 spiculated masses (5 - 7mm) and 6 microcalcification clusters (2 - 4mm) were scaled in 3D to create a range of sizes. The linear attenuation coefficient (AC) of the masses was adjusted from 100% glandular tissue to 90%, 80%, 70%, to create different contrasts. Six physicists read the full database on Barco's Coronis Uniti monitor for four different luminance levels (300, 800, 1000 and 1200 Cd/m2), using a 4-AFC tool. Percentage correct (PC) and time were computed for all different conditions. A paired t-test was performed to evaluate the effect of luminance on PC and time. A multi-factorial analysis was performed using MANOVA.. Results: Paired t-test indicated a statistically significant difference for the average time per session between 300 and 1200; 800 and 1200; 1000 and 1200 Cd/m2, for all participants combined. There was no effect on PC. MANOVA denoted significantly lower reading times for high glandularity images at 1200 Cd/m2. Both types of masses were significantly faster detected at 1200 Cd/m2, for the contrast study. In the size study, microcalcification clusters and spiculated masses had a significantly higher detection rate at 1200 Cd/m2. Conclusion: These results demonstrate a significant decrease in reading time, while detectability remained constant.

  4. Three-dimensional images contribute to the diagnosis of mucous retention cyst in maxillary sinus

    PubMed Central

    Donizeth-Rodrigues, Cleomar; Fonseca-Da Silveira, Márcia; Gonçalves-De Alencar, Ana H.; Garcia-Santos-Silva, Maria A.; Francisco-De-Mendonça, Elismauro

    2013-01-01

    Objective: To evaluate the detection of mucous retention cyst of maxillary sinus (MRCMS) using panoramic radiography and cone beam computed tomography (CBCT). Study Design: A digital database with 6,000 panoramic radiographs was reviewed for MRCMS. Suggestive images of MRCMS were detected on 185 radiographs, and patients were located and invited to return for follow-up. Thirty patients returned, and control panoramic radiographs were obtained 6 to 46 months after the initial radiograph. When MRCMS was found on control radiographs, CBCT scans were obtained. Cysts were measured and compared on radiographs and scans. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical analysis. The level of significance was set at 5%. Results: There were statistically significant differences between the two methods (p<0.05): 23 MRCMS detected on panoramic radiographs were confirmed by CBCT, but 5 MRCMS detected on CBCT images had not been identified by panoramic radiography. Eight MRCMS detected on control radiographs were not confirmed by CBCT. MRCMS size differences from initial to control panoramic radiographs and CBCT scans were not statistically significant (p= 0.617 and p= 0.626). The correlation between time and MRCMS size differences was not significant (r = -0.16, p = 0.381). Conclusion: CBCT scanning detect MRCMS more accurately than panoramic radiography. Key words:Mucous cyst, maxillary sinus, panoramic radiograph, cone beam computed tomography. PMID:23229251

  5. Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

    DTIC Science & Technology

    2007-09-01

    March 17, 2005. The seismic signals from both master and detected events are followed by infrasound arrivals. Note the long duration of the...correlation coefficient traces with a significant array -gain. A detected event that is co-located with the master event will record the same time-difference...estimating the detection threshold reduction for a range of highly repeating seismic sources using arrays of different configurations and at different

  6. Chapter 13: Interannual Differences in Detections of Marbled Murrelets in Some Inland California Stands

    Treesearch

    C. John Ralph

    1995-01-01

    I compared the mean level of detections of Marbled Murrelets by month over five years at three inland sites in northern California. These areas all have relatively high levels of detections. There were no significant differences in mean detection levels year to year at any site, and for any month with the exception of April at one site. This lack of evidence for...

  7. Autoantibodies other than Anti-desmogleins in Pemphigus Vulgaris Patients

    PubMed Central

    Saleh, Marwah Adly; Salem, Hedayat; El Azizy, Hoda

    2017-01-01

    Background: Pemphigus vulgaris (PV) is an immunoglobulin G-mediated autoimmune bullous skin disease. Nonorgan-specific antibodies were detected in Tunisian and Brazilian pemphigus patients with different prevalence. Materials and Methods: Fifty PV patients and fifty controls were screened for antinuclear antibodies (ANAs), anti-smooth muscle antibodies (ASMAs), anti-parietal antibodies (APAs), anti-mitochondrial antibodies, and Anti-nuclear cytoplasmic antibodies (ANCA) by indirect immunofluorescence. Results: Thirty-nine patients were female and 11 were male. Fifteen patients did not receive treatment before while 35 patients were on systemic steroid treatment ± azathioprine. Twenty (40%) of the PV patients and 1 (2%) control had positive ANA. ANA was significantly higher in PV patients than controls, P < 0.0001. ASMAs were detected in 20 (40%) PV patients and none of the controls. ASMA was significantly higher in PV patients than controls, P < 0.0001. No significant difference was detected between treated and untreated regarding ANA, P - 0.11. However, there was a significant difference between treated and untreated regarding ASMA, P - 0.03. Six patients (12%) and none of the controls had positive APA. There was a significant difference between the patients and the controls in APA. P - 0.027. Conclusion: Egyptian PV patients showed more prevalent ANA, ASMA, and APA than normal controls. Follow-up of those patients is essential to detect the early development of concomitant autoimmune disease. Environmental factors might account for the variability of the nonorgan-specific antibodies among different populations. PMID:28216725

  8. Measuring economic outcomes of alcohol treatment using the Economic Form 90.

    PubMed

    Bray, Jeremy W; Zarkin, Gary A; Miller, William R; Mitra, Debanjali; Kivlahan, Daniel R; Martin, Daniel J; Couper, David J; Cisler, Ron A

    2007-03-01

    This article assesses the ability of the economic outcome measures in the Economic Form 90 to detect differences across levels of alcohol dependence as measured by the Alcohol Dependence Scale. We used baseline data from the Combining Medications and Behavioral Interventions (COMBINE) Study, a large, multisite clinical trial, to assess the extent to which the economic items on the Economic Form 90 instrument can detect differences across levels of alcohol dependence. After adjusting for differences in demographic characteristics, the Economic Form 90 can detect significant differences across a range of dependence severity levels for the economic outcomes of inpatient medical care, emergency-department medical care, behavioral health care, being on parole or probation, and missed workdays, conditional on being employed. We did not detect significant differences across dependence severity for employment status, outpatient medical care, other criminal justice involvement, or motor vehicle accidents. The Economic Form 90 can identify differences in many economic outcomes associated with differing levels of alcohol dependence. This suggests that the Economic Form 90 may be useful in assessing changes in economic outcomes that result from changes in alcohol dependence.

  9. Characterization of the nasal and oral microbiota of detection dogs.

    PubMed

    Isaiah, Anitha; Hoffmann, Aline Rodrigues; Kelley, Russ; Mundell, Paul; Steiner, Jörg M; Suchodolski, Jan S

    2017-01-01

    Little is known about physiological factors that affect the sense of olfaction in dogs. The objectives of this study were to describe the canine nasal and oral microbiota in detection dogs. We sought to determine the bacterial composition of the nasal and oral microbiota of a diverse population of detection canines. Nasal and oral swabs were collected from healthy dogs (n = 81) from four locations-Alabama, Georgia, California, and Texas. Nasal and oral swabs were also collected from a second cohort of detection canines belonging to three different detection job categories: explosive detection dogs (SP-E; n = 22), patrol and narcotics detection dogs (P-NDD; n = 15), and vapor wake dogs (VWD-E; n = 9). To understand if the nasal and oral microbiota of detection canines were variable, sample collection was repeated after 7 weeks in a subset of dogs. DNA was extracted from the swabs and used for 454-pyrosequencing of the16S rRNA genes. Nasal samples had a significantly lower diversity than oral samples (P<0.01). Actinobacteria and Proteobacteria were higher in nasal samples, while Bacteroidetes, Firmicutes, Fusobacteria, and Tenericutes were higher in oral samples. Bacterial diversity was not significantly different based on the detection job. No significant difference in beta diversity was observed in the nasal samples based on the detection job. In oral samples, however, ANOSIM suggested a significant difference in bacterial communities based on job category albeit with a small effect size (R = 0.1079, P = 0.02). Analysis of the composition of bacterial communities using LEfSe showed that within the nasal samples, Cardiobacterium and Riemerella were higher in VWD-E dogs, and Sphingobacterium was higher in the P-NDD group. In the oral samples Enterococcus and Capnocytophaga were higher in the P-NDD group. Gemella and Aggregatibacter were higher in S-PE, and Pigmentiphaga, Chryseobacterium, Parabacteroides amongst others were higher within the VWD-E group. Our initial data also shows that there is a temporal variation in alpha diversity in nasal samples in detection canines.

  10. Characterization of the nasal and oral microbiota of detection dogs

    PubMed Central

    Hoffmann, Aline Rodrigues; Kelley, Russ; Mundell, Paul; Steiner, Jörg M.

    2017-01-01

    Little is known about physiological factors that affect the sense of olfaction in dogs. The objectives of this study were to describe the canine nasal and oral microbiota in detection dogs. We sought to determine the bacterial composition of the nasal and oral microbiota of a diverse population of detection canines. Nasal and oral swabs were collected from healthy dogs (n = 81) from four locations—Alabama, Georgia, California, and Texas. Nasal and oral swabs were also collected from a second cohort of detection canines belonging to three different detection job categories: explosive detection dogs (SP-E; n = 22), patrol and narcotics detection dogs (P-NDD; n = 15), and vapor wake dogs (VWD-E; n = 9). To understand if the nasal and oral microbiota of detection canines were variable, sample collection was repeated after 7 weeks in a subset of dogs. DNA was extracted from the swabs and used for 454-pyrosequencing of the16S rRNA genes. Nasal samples had a significantly lower diversity than oral samples (P<0.01). Actinobacteria and Proteobacteria were higher in nasal samples, while Bacteroidetes, Firmicutes, Fusobacteria, and Tenericutes were higher in oral samples. Bacterial diversity was not significantly different based on the detection job. No significant difference in beta diversity was observed in the nasal samples based on the detection job. In oral samples, however, ANOSIM suggested a significant difference in bacterial communities based on job category albeit with a small effect size (R = 0.1079, P = 0.02). Analysis of the composition of bacterial communities using LEfSe showed that within the nasal samples, Cardiobacterium and Riemerella were higher in VWD-E dogs, and Sphingobacterium was higher in the P-NDD group. In the oral samples Enterococcus and Capnocytophaga were higher in the P-NDD group. Gemella and Aggregatibacter were higher in S-PE, and Pigmentiphaga, Chryseobacterium, Parabacteroides amongst others were higher within the VWD-E group. Our initial data also shows that there is a temporal variation in alpha diversity in nasal samples in detection canines. PMID:28934260

  11. Accuracy of noncycloplegic retinoscopy, retinomax autorefractor, and SureSight vision screener for detecting significant refractive errors.

    PubMed

    Kulp, Marjean Taylor; Ying, Gui-Shuang; Huang, Jiayan; Maguire, Maureen; Quinn, Graham; Ciner, Elise B; Cyert, Lynn A; Orel-Bixler, Deborah A; Moore, Bruce D

    2014-03-06

    To evaluate, by receiver operating characteristic (ROC) analysis, the ability of noncycloplegic retinoscopy (NCR), Retinomax Autorefractor (Retinomax), and SureSight Vision Screener (SureSight) to detect significant refractive errors (RE) among preschoolers. Refraction results of eye care professionals using NCR, Retinomax, and SureSight (n = 2588) and of nurse and lay screeners using Retinomax and SureSight (n = 1452) were compared with masked cycloplegic retinoscopy results. Significant RE was defined as hyperopia greater than +3.25 diopters (D), myopia greater than 2.00 D, astigmatism greater than 1.50 D, and anisometropia greater than 1.00 D interocular difference in hyperopia, greater than 3.00 D interocular difference in myopia, or greater than 1.50 D interocular difference in astigmatism. The ability of each screening test to identify presence, type, and/or severity of significant RE was summarized by the area under the ROC curve (AUC) and calculated from weighted logistic regression models. For detection of each type of significant RE, AUC of each test was high; AUC was better for detecting the most severe levels of RE than for all REs considered important to detect (AUC 0.97-1.00 vs. 0.92-0.93). The area under the curve of each screening test was high for myopia (AUC 0.97-0.99). Noncycloplegic retinoscopy and Retinomax performed better than SureSight for hyperopia (AUC 0.92-0.99 and 0.90-0.98 vs. 0.85-0.94, P ≤ 0.02), Retinomax performed better than NCR for astigmatism greater than 1.50 D (AUC 0.95 vs. 0.90, P = 0.01), and SureSight performed better than Retinomax for anisometropia (AUC 0.85-1.00 vs. 0.76-0.96, P ≤ 0.07). Performance was similar for nurse and lay screeners in detecting any significant RE (AUC 0.92-1.00 vs. 0.92-0.99). Each test had a very high discriminatory power for detecting children with any significant RE.

  12. Correlation between systemic lupus erythematosus and cytomegalovirus infection detected by different methods.

    PubMed

    Chen, Jing; Zhang, Huidi; Chen, Peirong; Lin, Qiaoai; Zhu, Xiaochun; Zhang, Lifang; Xue, Xiangyang

    2015-04-01

    Human cytomegalovirus (HCMV), a β-herpes virus subfamily member, leads to a lifelong, latent infection in most humans, but the correlation between HCMV infection and systemic lupus erythematosus (SLE) remains controversial. We analyzed the relevance of HCMV infection in SLE by analyzing the peripheral blood leukocytes (PBLs) and serum samples of 60 patients with SLE and 111 healthy individuals. HCMV genes UL55 and UL138 were detected in PBLs by polymerase chain reaction (PCR), and HCMV-specific serum IgG and IgM antibodies were investigated by enzyme-linked immunosorbent assay. The relationship between cellular HCMV infection in PBLs and common clinical indicators of SLE was further explored. Data indicated that the frequency of positive IgG and IgM anti-CMV antibodies was not significantly different in SLE patients and controls. However, compared to the healthy controls, the titers of IgG and IgM anti-CMV antibodies in SLE patients were significantly higher. The detection of cellular HCMV infection showed that almost all subjects were positive for UL138 gene in PBLs, but the positivity for UL55 gene was lower in PBLs. HCMV UL138 detection in PBLs was highly consistent with the frequency of the HCMV-specific IgG test and did not show significant difference in SLE patients and healthy controls. However, compared with that in healthy people, the positivity rate for cellular HCMV UL55 detection was significantly higher in SLE patients (P < 0.001). In addition, cellular HCMV UL55 with positive detection in PBLs was associated with significantly different clinical characteristics of SLE than that with negative detection. In conclusion, our data confirmed that the HCMV infection was related to the development of SLE. Especially, some clinical strains or substrains of HCMV, such as containing the UL55 gene in HCMV's genome, might play a vital role in the development of SLE.

  13. Impact of adding artificially generated alert sound to hybrid electric vehicles on their detectability by pedestrians who are blind.

    PubMed

    Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh; Pliskow, Jay; Myers, Kyle

    2012-01-01

    A repeated-measures design with block randomization was used for the study, in which 14 adults with visual impairments attempted to detect three different vehicles: a hybrid electric vehicle (HEV) with an artificially generated sound (Vehicle Sound for Pedestrians [VSP]), an HEV without the VSP, and a comparable internal combustion engine (ICE) vehicle. The VSP vehicle (mean +/- standard deviation [SD] = 38.3 +/- 14.8 m) was detected at a significantly farther distance than the HEV (mean +/- SD = 27.5 +/- 11.5 m), t = 4.823, p < 0.001, but no significant difference existed between the VSP and ICE vehicles (mean +/- SD = 34.5 +/- 14.3 m), t = 1.787, p = 0.10. Despite the overall sound level difference between the two test sites (parking lot = 48.7 dBA, roadway = 55.1 dBA), no significant difference in detection distance between the test sites was observed, F(1, 13) = 0.025, p = 0.88. No significant interaction was found between the vehicle type and test site, F(1.31, 16.98) = 0.272, p = 0.67. The findings of the study may help us understand how adding an artificially generated sound to an HEV could affect some of the orientation and mobility tasks performed by blind pedestrians.

  14. Colorectal cancer lymph node staining by activated carbon nanoparticles suspension in vivo or methylene blue in vitro

    PubMed Central

    Cai, Hong-Ke; He, Hai-Fei; Tian, Wei; Zhou, Mei-Qi; Hu, Yue; Deng, Yong-Chuan

    2012-01-01

    AIM: To investigate whether activated carbon nanoparticles suspension (ACNS) or methylene blue (MB) can increase the detected number of lymph nodes in colorectal cancer. METHODS: Sixty-seven of 72 colorectal cancer patients treated at our hospital fulfilled the inclusion criteria of the study which was conducted from December 2010 to February 2012. Seven patients refused to participate. Eventually, 60 patients were included, and randomly assigned to three groups (20 in each group): ACNS group (group A), MB group (group B) and non-stained conventional surgical group (group C). In group A, patients received subserosal injection of 1 mL ACNS in a 4-quadrant region around the mass. In group B, the main artery of specimen was identified and isolated after the specimen was removed, and 2 mL MB was slowly injected into the isolated, stretched and fixed vessel. In group C, no ACNS and MB were injected. All the mesentery lymph nodes were isolated and removed systematically by visually inspecting and palpating the adipose tissue. RESULTS: No difference was observed among the three groups in age, gender, tumor location, tumor diameter, T-stage, degree of differentiation, postoperative complications and peritoneal drainage retention time. The total number of detected lymph nodes was 535, 476 and 223 in the three groups, respectively. The mean number of detected lymph nodes per patient was significantly higher in group A than in group C (26.8 ± 8.4 vs 12.2 ± 3.2, P < 0.001). Similarly, there were significantly more lymph nodes detected in group B than in group C (23.8 ± 6.9 vs 12.2 ± 3.2, P < 0.001). However, there was no significant difference between group A and group B. There were 50, 46 and 32 metastatic lymph nodes dissected in 13 patients of group A, 10 patients of group B and 11 patients of group C, without significant differences among the three groups. Eleven of the 60 patients had insufficient number of detected lymph nodes (< 12). Only one patient with T4a rectal cancer had 10 lymph nodes detected in group B, the other 10 patients were all from group C. Based on the different diameter categories, the number of detected lymph nodes in groups A and B was significantly higher than in group C. However, there was no statistically significant difference between group A and group B. The metastatic lymph nodes were not significant different among the three groups. Similarly, tumor location, T stage and tumor differentiation did not affect the staining results. Body mass index was a minor influencing factor in the two different staining methods. The stained lymph nodes can easily be identified from the mesenteric adipose tissues, and the staining time for lymph nodes was not significantly different compared with unstained group. None of the patients in groups A and B had drug-related complications. CONCLUSION: Both activated carbon nanoparticles suspension in vivo and methylene blue in vitro can be used as tracers to increase the detected number of lymph nodes in colorectal cancer. PMID:23155345

  15. Comparison of four different methods for detection of biofilm formation by uropathogens.

    PubMed

    Panda, Pragyan Swagatika; Chaudhary, Uma; Dube, Surya K

    2016-01-01

    Urinary tract infection (UTI) is one of the most common infectious diseases encountered in clinical practice. Emerging resistance of the uropathogens to the antimicrobial agents due to biofilm formation is a matter of concern while treating symptomatic UTI. However, studies comparing different methods for detection of biofilm by uropathogens are scarce. To compare four different methods for detection of biofilm formation by uropathogens. Prospective observational study conducted in a tertiary care hospital. Totally 300 isolates from urinary samples were analyzed for biofilm formation by four methods, that is, tissue culture plate (TCP) method, tube method (TM), Congo Red Agar (CRA) method and modified CRA (MCRA) method. Chi-square test was applied when two or more set of variables were compared. P < 0.05 considered as statistically significant. Considering TCP to be a gold standard method for our study we calculated other statistical parameters. The rate of biofilm detection was 45.6%, 39.3% and 11% each by TCP, TM, CRA and MCRA methods, respectively. The difference between TCP and only CRA/MCRA was significant, but not that between TCP and TM. There was no difference in the rate of biofilm detection between CRA and MCRA in other isolates, but MCRA is superior to CRA for detection of the staphylococcal biofilm formation. TCP method is the ideal method for detection of bacterial biofilm formation by uropathogens. MCRA method is superior only to CRA for detection of staphylococcal biofilm formation.

  16. Haptic discrimination of bilateral symmetry in 2-dimensional and 3-dimensional unfamiliar displays.

    PubMed

    Ballesteros, S; Manga, D; Reales, J M

    1997-01-01

    In five experiments, we tested the accuracy and sensitivity of the haptic system in detecting bilateral symmetry of raised-line shapes (Experiments 1 and 2) and unfamiliar 3-D objects (Experiments 3-5) under different time constraints and different modes of exploration. Touch was moderately accurate for detecting this property in raised displays. Experiment 1 showed that asymmetric judgments were systematically more accurate than were symmetric judgements with scanning by one finger. Experiments 2 confirmed the results of Experiment 1 but also showed that bimanual exploration facilitated processing of symmetric shapes without improving asymmetric detections. Bimanual exploration of 3-D objects was very accurate and significantly facilitated processing of symmetric objects under different time constraints (Experiment 3). Unimanual exploration did not differ from bimanual exploration (Experiment 4), but restricting hand movements to one enclosure reduced performance significantly (Experiment 5). Spatial reference information, signal detection measures, and hand movements in processing bilateral symmetry by touch are discussed.

  17. Detection of ischemical dyssynchrony in patients with normal duration of QRS at rest and during exercise echocardiography (Dyssynchrony in coronary artery disease patients during exercise).

    PubMed

    Zagatina, A; Guseva, O; Bartosh-Zelenaya, S Y; Zhuravskaya, N

    2014-04-01

    Ischemic segments cannot develop a sufficient amount of strength during systole, so theoretically they begin to contract later in comparison with non-ischemic zones. There is a lack of information about methods that can detect dyssynchrony during exercise in patients with QRS not longer 100 ms. The aim of the study was to compare different methods of detection regarding left ventricular moving dyssynchrony in patients with significant coronary stenosis artery lesions: pulsed-wave of PW-TDI, strain (S) and strain rate (SR). The study included 133 subjects: 106 consecutive patients who were scheduled for coronary angiography with previous stress-echocardiography and 27 healthy persons. All the patients underwent a supine bicycle exercise test. Seventy-six patients had stenoses and 30 subjects had no significant lesions by coronary angiography. There was a detectable difference between time parameters of left ventricle contraction for the two groups and controls before and during exercise using all Doppler methods. Subgroups of patients without previous myocardial infarction and without hypertrophy of left ventricle had the same results. Maximal difference was observed using strain method. There was a moderate correlation between time parameters and the existence of significant lesions of coronary arteries. Patients without prolongations of QRS with significant lesions of coronary arteries have detectable left ventricular dyssynchrony before and during exercise.

  18. A biological evaluation of DNA damage detected by comet assay in healthy populations residing in areas that differ in lung cancer incidence.

    PubMed

    Heepchantree, Worapa; Paratasilpin, Thipmani; Kangwanpong, Daoroong

    2006-06-01

    The comet assay was performed to evaluate the effect of environmental exposure between human populations residing in two areas that differ in lung cancer incidence, Saraphi (n = 91) and Chom Thong (n = 94). Three parameters, the tail length, tail intensity, and tail moment, were used to detect DNA damage in peripheral blood and stimulated lymphocytes with and without the DNA repair inhibitor, aphidicolin. Internal standards, cryopreserved isolated lymphocytes, and isolated lymphocytes irradiated with 2 Gy gamma rays, were used to correct the interexperimental variability. Results revealed a significant difference between two populations only when the tail length was used to measure DNA damage. The evaluation of various potential confounding factors, such as gender, pesticide exposure, smoking, alcohol drinking, and fermented tea leaf or betel nut chewing, indicated no significant influence in DNA damage. In conclusion, significant difference in DNA damage, detected only by tail length between the two populations residing in the areas with different incidence of lung cancer, may reflect a nonhazardous level of exposure to toxic substances.

  19. Comparison between nasopharyngeal swab and nasal wash, using culture and PCR, in the detection of potential respiratory pathogens.

    PubMed

    Gritzfeld, Jenna F; Roberts, Paul; Roche, Lorna; El Batrawy, Sherouk; Gordon, Stephen B

    2011-04-13

    Nasopharyngeal carriage of potential pathogens is important as it is both the major source of transmission and the prerequisite of invasive disease. New methods for detecting carriage could improve comfort, accuracy and laboratory utility. The aims of this study were to compare the sensitivities of a nasopharyngeal swab (NPS) and a nasal wash (NW) in detecting potential respiratory pathogens in healthy adults using microbiological culture and PCR. Healthy volunteers attended for nasal washing and brushing of the posterior nasopharynx. Conventional and real-time PCR were used to detect pneumococcus and meningococcus. Statistical differences between the two nasal sampling methods were determined using a nonparametric Mann-Whitney U test; differences between culture and PCR methods were determined using the McNemar test.Nasal washing was more comfortable for volunteers than swabbing (n = 24). In detection by culture, the NW was significantly more likely to detect pathogens than the NPS (p < 0.00001). Overall, there was a low carriage rate of pathogens in this sample; no significant difference was seen in the detection of bacteria between culture and PCR methods. Nasal washing and PCR may provide effective alternatives to nasopharyngeal swabbing and classical microbiology, respectively.

  20. Effect of cane length and swing arc width on drop-off and obstacle detection with the long cane

    PubMed Central

    Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh

    2017-01-01

    A repeated-measures design with block randomization was used for the study, in which 15 adults with visual impairments attempted to detect the drop-offs and obstacles with the canes of different lengths, swinging the cane in different widths (narrow vs wide). Participants detected the drop-offs significantly more reliably with the standard-length cane (79.5% ± 6.5% of the time) than with the extended-length cane (67.6% ± 9.1%), p <.001. The drop-off detection threshold of the standard-length cane (4.1 ± 1.1 cm) was also significantly smaller than that of the extended-length cane (6.5±1.8cm), p <.001. In addition, participants detected drop-offs at a significantly higher percentage when they swung the cane approximately 3 cm beyond the widest part of the body (78.6% ± 7.6%) than when they swung it substantially wider (30 cm; 68.5% ± 8.3%), p <.001. In contrast, neither cane length (p =.074) nor cane swing arc width (p =.185) had a significant effect on obstacle detection performance. The findings of the study may help orientation and mobility specialists recommend appropriate cane length and cane swing arc width to visually impaired cane users. PMID:29276326

  1. Effect of cane length and swing arc width on drop-off and obstacle detection with the long cane.

    PubMed

    Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh

    2017-09-01

    A repeated-measures design with block randomization was used for the study, in which 15 adults with visual impairments attempted to detect the drop-offs and obstacles with the canes of different lengths, swinging the cane in different widths (narrow vs wide). Participants detected the drop-offs significantly more reliably with the standard-length cane (79.5% ± 6.5% of the time) than with the extended-length cane (67.6% ± 9.1%), p <.001. The drop-off detection threshold of the standard-length cane (4.1 ± 1.1 cm) was also significantly smaller than that of the extended-length cane (6.5±1.8cm), p <.001. In addition, participants detected drop-offs at a significantly higher percentage when they swung the cane approximately 3 cm beyond the widest part of the body (78.6% ± 7.6%) than when they swung it substantially wider (30 cm; 68.5% ± 8.3%), p <.001. In contrast, neither cane length ( p =.074) nor cane swing arc width ( p =.185) had a significant effect on obstacle detection performance. The findings of the study may help orientation and mobility specialists recommend appropriate cane length and cane swing arc width to visually impaired cane users.

  2. Relevance of calpain and calpastatin activity for texture in super-chilled and ice-stored Atlantic salmon (Salmo salar L.) fillets.

    PubMed

    Gaarder, M Ø; Bahuaud, D; Veiseth-Kent, E; Mørkøre, T; Thomassen, M S

    2012-05-01

    The aim of the present experiment was to measure the protease activities in ice-stored and super-chilled Atlantic salmon (Salmo salar) fillets, and the effect on texture. Pre-rigour fillets of Atlantic salmon were either super-chilled to a core temperature of -1.5°C or directly chilled on ice prior to 144h of ice storage. A significantly higher calpain activity was detected in the super-chilled fillets at 6h post-treatment compared to the ice-stored fillets and followed by a significant decrease below its initial level, while the calpastatin activity was significantly lower for the super-chilled fillets at all time points. The cathepsin B+L and B activities increased significantly with time post-treatment; however, no significant differences were observed at any time points between the two treatments. For the ice stored fillets, the cathepsin L activity decreased significantly from 6 to 24h post-treatment and thereafter increased significantly to 144h post-treatment. There was also a significantly lower cathepsin L activity in the super-chilled fillets at 0h post-treatment. No significant difference in breaking force was detected; however, a significant difference in maximum compression (Fmax) was detected at 24h post-treatment with lower Fmax in the super-chilled fillets. This experiment showed that super-chilling had a significant effect on the protease activities and the ATP degradation in salmon fillets. The observed difference in Fmax may be a result of these observed differences, and may indicate a softening of the super-chilled salmon muscle at 24h post-treatment. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Impact of adding artificially generated alert sound to hybrid electric vehicles on their detectability by pedestrians who are blind

    PubMed Central

    Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh; Pliskow, Jay; Myers, Kyle

    2012-01-01

    A repeated-measures design with block randomization was used for the study, in which 14 adults with visual impairments attempted to detect three different vehicles: a hybrid electric vehicle (HEV) with an artificially generated sound (Vehicle Sound for Pedestrians [VSP]), an HEV without the VSP, and a comparable internal combustion engine (ICE) vehicle. The VSP vehicle (mean +/− standard deviation [SD] = 38.3 +/− 14.8 m) was detected at a significantly farther distance than the HEV (mean +/− SD = 27.5 +/− 11.5 m), t = 4.823, p < 0.001, but no significant difference existed between the VSP and ICE vehicles (mean +/− SD = 34.5 +/− 14.3 m), t = 1.787, p = 0.10. Despite the overall sound level difference between the two test sites (parking lot = 48.7 dBA, roadway = 55.1 dBA), no significant difference in detection distance between the test sites was observed, F(1, 13) = 0.025, p = 0.88. No significant interaction was found between the vehicle type and test site, F(1.31, 16.98) = 0.272, p = 0.67. The findings of the study may help us understand how adding an artificially generated sound to an HEV could affect some of the orientation and mobility tasks performed by blind pedestrians. PMID:22773198

  4. BMI and breast cancer prognosis benefit: mammography screening reveals differences between normal weight and overweight women.

    PubMed

    Crispo, Anna; Grimaldi, Maria; D'Aiuto, Massimiliano; Rinaldo, Massimo; Capasso, Immacolata; Amore, Alfonso; D'Aiuto, Giuseppe; Giudice, Aldo; Ciliberto, Gennaro; Montella, Maurizio

    2015-02-01

    Few studies are available on the potential impact of body weight on breast cancer prognosis in screen-detected patients. Moreover, it is not known whether body mass index (BMI) could have a different prognostic impact in screen-detected versus symptomatic breast cancer patients. To investigate these unsolved issues, we carried out a retrospective study evaluating the effect of BMI on breast cancer prognosis in screen-detected vs symptomatic breast cancer patients. We conducted a follow-up study on 448 women diagnosed with incident, histologically-confirmed breast cancer. Patients were categorized according to their BMI as normal weight, overweight and obese. Disease free survival (DFS), overall survival (OS), and BMI curves were compared according to mode of cancer detection. Among screen-detected patients, higher BMI was associated with a significant lower DFS, whereas no significant difference was observed among symptomatic patients. OS showed similar results. In the multivariate analysis adjusting for age, education, tumor size, nodal status, estrogen receptor (ER), progesterone receptor (PR) and menopausal status, the risk for high level of BMI among screen-detected patients did not reach the statistical significance for either recurrence or survival. Our study highlights the potential impact of high bodyweight in breast cancer prognosis, the findings confirm that obesity plays a role in women breast cancer prognosis independently from diagnosis mode. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Thermal sensitivity and cardiovascular reactivity to stress in healthy males.

    PubMed

    Conde-Guzón, Pablo Antonio; Bartolomé-Albistegui, María Teresa; Quirós, Pilar; Cabestrero, Raúl

    2011-11-01

    This paper examines the association of cardiovascular reactivity with thermal thresholds (detection and unpleasantness). Heart period (HP), systolic (SBP) and diastolic (DBP) blood pressure of 42 health young males were recorded during a cardiovascular reactivity task (a videogame based upon Sidman's avoidance paradigm). Thermal sensitivity, assessing detection and unpleasantness thresholds with radiant heat in the forearm was also estimated for participants. Participants with differential scores in the cardiovascular variables from base line to task > or = P65 were considered as reactors and those how have differential scores < or = P35 were considered as non-reactors. Significant differences were observed between groups in the unpleasantness thresholds in blood pressure (BP) but not in HP. Reactors exhibited significant higher unpleasantness thresholds than non-reactors. No significant differences were obtained in detection thresholds between groups.

  6. Accuracy of Noncycloplegic Retinoscopy, Retinomax Autorefractor, and SureSight Vision Screener for Detecting Significant Refractive Errors

    PubMed Central

    Kulp, Marjean Taylor; Ying, Gui-shuang; Huang, Jiayan; Maguire, Maureen; Quinn, Graham; Ciner, Elise B.; Cyert, Lynn A.; Orel-Bixler, Deborah A.; Moore, Bruce D.

    2014-01-01

    Purpose. To evaluate, by receiver operating characteristic (ROC) analysis, the ability of noncycloplegic retinoscopy (NCR), Retinomax Autorefractor (Retinomax), and SureSight Vision Screener (SureSight) to detect significant refractive errors (RE) among preschoolers. Methods. Refraction results of eye care professionals using NCR, Retinomax, and SureSight (n = 2588) and of nurse and lay screeners using Retinomax and SureSight (n = 1452) were compared with masked cycloplegic retinoscopy results. Significant RE was defined as hyperopia greater than +3.25 diopters (D), myopia greater than 2.00 D, astigmatism greater than 1.50 D, and anisometropia greater than 1.00 D interocular difference in hyperopia, greater than 3.00 D interocular difference in myopia, or greater than 1.50 D interocular difference in astigmatism. The ability of each screening test to identify presence, type, and/or severity of significant RE was summarized by the area under the ROC curve (AUC) and calculated from weighted logistic regression models. Results. For detection of each type of significant RE, AUC of each test was high; AUC was better for detecting the most severe levels of RE than for all REs considered important to detect (AUC 0.97–1.00 vs. 0.92–0.93). The area under the curve of each screening test was high for myopia (AUC 0.97–0.99). Noncycloplegic retinoscopy and Retinomax performed better than SureSight for hyperopia (AUC 0.92–0.99 and 0.90–0.98 vs. 0.85–0.94, P ≤ 0.02), Retinomax performed better than NCR for astigmatism greater than 1.50 D (AUC 0.95 vs. 0.90, P = 0.01), and SureSight performed better than Retinomax for anisometropia (AUC 0.85–1.00 vs. 0.76–0.96, P ≤ 0.07). Performance was similar for nurse and lay screeners in detecting any significant RE (AUC 0.92–1.00 vs. 0.92–0.99). Conclusions. Each test had a very high discriminatory power for detecting children with any significant RE. PMID:24481262

  7. High endemicity of human fascioliasis between Lake Titicaca and La Paz valley, Bolivia.

    PubMed

    Esteban, J G; Flores, A; Angles, R; Mas-Coma, S

    1999-01-01

    Over a 6-year period, an epidemiological study of human infection by Fasciola hepatica in the Northern Bolivian Altiplano was carried out. Prevalences and intensities were analysed from coprological results obtained in 31 surveys performed in 24 localities and proved to be the highest known so far. The global prevalence was 15.4%, with local prevalences ranging from 0% to 68.2%. Significant differences between prevalence rates were detected and the highest prevalences were in subjects aged < 20 years. However, prevalences showed no gender difference. The global intensity (eggs per gram of faeces, epg) ranged from 24 to 5064 epg and showed arithmetic and geometric means respectively of 446 and 191 epg, with highest local arithmetic and geometric means of 1345 and 678 epg. Significant differences in mean egg output were detected between localities. The significantly higher F. hepatica egg counts shown by girls in school surveys is worth mentioning. Although the distributions of intensities according to age-groups did not show any significant difference, a decrease of egg output counts with an increase of age was detected. It is concluded that fascioliasis is a very important human health problem in this region.

  8. [Optimized application of nested PCR method for detection of malaria].

    PubMed

    Yao-Guang, Z; Li, J; Zhen-Yu, W; Li, C

    2017-04-28

    Objective To optimize the application of the nested PCR method for the detection of malaria according to the working practice, so as to improve the efficiency of malaria detection. Methods Premixing solution of PCR, internal primers for further amplification and new designed primers that aimed at two Plasmodium ovale subspecies were employed to optimize the reaction system, reaction condition and specific primers of P . ovale on basis of routine nested PCR. Then the specificity and the sensitivity of the optimized method were analyzed. The positive blood samples and examination samples of malaria were detected by the routine nested PCR and the optimized method simultaneously, and the detection results were compared and analyzed. Results The optimized method showed good specificity, and its sensitivity could reach the pg to fg level. The two methods were used to detect the same positive malarial blood samples simultaneously, the results indicated that the PCR products of the two methods had no significant difference, but the non-specific amplification reduced obviously and the detection rates of P . ovale subspecies improved, as well as the total specificity also increased through the use of the optimized method. The actual detection results of 111 cases of malarial blood samples showed that the sensitivity and specificity of the routine nested PCR were 94.57% and 86.96%, respectively, and those of the optimized method were both 93.48%, and there was no statistically significant difference between the two methods in the sensitivity ( P > 0.05), but there was a statistically significant difference between the two methods in the specificity ( P < 0.05). Conclusion The optimized PCR can improve the specificity without reducing the sensitivity on the basis of the routine nested PCR, it also can save the cost and increase the efficiency of malaria detection as less experiment links.

  9. Evaluation of different time domain peak models using extreme learning machine-based peak detection for EEG signal.

    PubMed

    Adam, Asrul; Ibrahim, Zuwairie; Mokhtar, Norrima; Shapiai, Mohd Ibrahim; Cumming, Paul; Mubin, Marizan

    2016-01-01

    Various peak models have been introduced to detect and analyze peaks in the time domain analysis of electroencephalogram (EEG) signals. In general, peak model in the time domain analysis consists of a set of signal parameters, such as amplitude, width, and slope. Models including those proposed by Dumpala, Acir, Liu, and Dingle are routinely used to detect peaks in EEG signals acquired in clinical studies of epilepsy or eye blink. The optimal peak model is the most reliable peak detection performance in a particular application. A fair measure of performance of different models requires a common and unbiased platform. In this study, we evaluate the performance of the four different peak models using the extreme learning machine (ELM)-based peak detection algorithm. We found that the Dingle model gave the best performance, with 72 % accuracy in the analysis of real EEG data. Statistical analysis conferred that the Dingle model afforded significantly better mean testing accuracy than did the Acir and Liu models, which were in the range 37-52 %. Meanwhile, the Dingle model has no significant difference compared to Dumpala model.

  10. Robust detection of multiple sclerosis lesions from intensity-normalized multi-channel MRI

    NASA Astrophysics Data System (ADS)

    Karpate, Yogesh; Commowick, Olivier; Barillot, Christian

    2015-03-01

    Multiple sclerosis (MS) is a disease with heterogeneous evolution among the patients. Quantitative analysis of longitudinal Magnetic Resonance Images (MRI) provides a spatial analysis of the brain tissues which may lead to the discovery of biomarkers of disease evolution. Better understanding of the disease will lead to a better discovery of pathogenic mechanisms, allowing for patient-adapted therapeutic strategies. To characterize MS lesions, we propose a novel paradigm to detect white matter lesions based on a statistical framework. It aims at studying the benefits of using multi-channel MRI to detect statistically significant differences between each individual MS patient and a database of control subjects. This framework consists in two components. First, intensity standardization is conducted to minimize the inter-subject intensity difference arising from variability of the acquisition process and different scanners. The intensity normalization maps parameters obtained using a robust Gaussian Mixture Model (GMM) estimation not affected by the presence of MS lesions. The second part studies the comparison of multi-channel MRI of MS patients with respect to an atlas built from the control subjects, thereby allowing us to look for differences in normal appearing white matter, in and around the lesions of each patient. Experimental results demonstrate that our technique accurately detects significant differences in lesions consequently improving the results of MS lesion detection.

  11. Comparison between target magnetic resonance imaging (MRI) in-gantry and cognitively directed transperineal or transrectal-guided prostate biopsies for Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 MRI lesions.

    PubMed

    Yaxley, Anna J; Yaxley, John W; Thangasamy, Isaac A; Ballard, Emma; Pokorny, Morgan R

    2017-11-01

    To compare the detection rates of prostate cancer (PCa) in men with Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 abnormalities on 3-Tesla multiparametric (mp) magnetic resonance imaging (MRI) using in-bore MRI-guided biopsy compared with cognitively directed transperineal (cTP) biopsy and transrectal ultrasonography (cTRUS) biopsy. This was a retrospective single-centre study of consecutive men attending the private practice clinic of an experienced urologist performing MRI-guided biopsy and an experienced urologist performing cTP and cTRUS biopsy techniques for PI-RADS 3-5 lesions identified on 3-Tesla mpMRI. There were 595 target mpMRI lesions from 482 men with PI-RADS 3-5 regions of interest during 483 episodes of biopsy. The abnormal mpMRI target lesion was biopsied using the MRI-guided method for 298 biopsies, the cTP method for 248 biopsies and the cTRUS method for 49 biopsies. There were no significant differences in PCa detection among the three biopsy methods in PI-RADS 3 (48.9%, 40.0% and 44.4%, respectively), PI-RADS 4 (73.2%, 81.0% and 85.0%, respectively) or PI-RADS 5 (95.2, 92.0% and 95.0%, respectively) lesions, and there was no significant difference in detection of significant PCa among the biopsy methods in PI-RADS 3 (42.2%, 30.0% and 33.3%, respectively), PI-RADS 4 (66.8%, 66.0% and 80.0%, respectively) or PI-RADS 5 (90.5%, 89.8% and 90.0%, respectively) lesions. There were also no differences in PCa or significant PCa detection based on lesion location or size among the methods. We found no significant difference in the ability to detect PCa or significant PCa using targeted MRI-guided, cTP or cTRUS biopsy methods. Identification of an abnormal area on mpMRI appears to be more important in increasing the detection of PCa than the technique used to biopsy an MRI abnormality. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  12. Characteristics of right-sided colonic neoplasia and colonoscopy barriers limiting their early detection and prognosis: a review of the literature.

    PubMed

    Fischbach, Wolfgang; Elsome, Rory; Amlani, Bharat

    2018-06-05

    Colonoscopy provides less protection from colorectal cancer in the right colon than the left. Areas covered: This review examines patient outcomes and colonoscopy success rates to identify factors that limit the protective effect of colonoscopy in the right colon. The MEDLINE and Embase databases were searched for literature from 2000 onwards, on the long-term outcomes and differences in screening practice between the right and left colon. In total, 12 systematic reviews (including nine meta-analyses) and 44 primary data records were included. Differences in patient outcomes and colonoscopy practice were identified between the right and left colon, suggesting that several factors, many of which disproportionally affect the right colon, impact lesion detection rates. Shorter withdrawal times reduce detection rates, while longer times significantly increase detection; mostly of adenomas in the right colon. Colonoscope attachments often only show a significant improvement in detection rates in the right colon, suggesting detection is more challenging due to visibility of the right colonic mucosa. Higher bowel cleansing grades significantly improve detection rates in the right colon compared to the left. Expert commentary: These findings confirm the need for continued improvement of colonoscopy effectiveness, and obligatory quality assessment, overall and especially in the right colon.

  13. Detection and distribution of ostreid herpesvirus 1 in experimentally infected Pacific oyster spat.

    PubMed

    Segarra, Amélie; Baillon, Laury; Faury, Nicole; Tourbiez, Delphine; Renault, Tristan

    2016-01-01

    High mortality rates are reported in spat and larvae of Pacific oyster Crassostrea gigas and associated with ostreid herpesvirus 1 (OsHV-1) detection in France. Although the viral infection has been experimentally reproduced in oyster larvae and spat, little knowledge is currently available concerning the viral entry and its distribution in organs and tissues. This study compares OsHV-1 DNA and RNA detection and localization in experimentally infected oysters using two virus doses: a low dose that did not induce any mortality and a high dose inducing high mortality. Real time PCR demonstrated significant differences in terms of viral DNA amounts between the two virus doses. RNA transcripts were detected in oysters receiving the highest dose of viral suspension whereas no transcript was observed in oysters injected with the low dose. This study also allowed observing kinetics of viral DNA and RNA detection in different tissues of oyster spat. Finally, viral detection was significantly different in function of tissues (p<0.005), time (p<0.005) with an interaction between tissues and time (p<0.005) for each probe. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. [G6PD deficiency among children under 7 years old from Yunnan with unique ethnic minority origin].

    PubMed

    Yao, Li-qin; Zou, Tuan-biao; Wang, Xing-tian; Quan, Xing; Chen, Qian; Yang, Fa-bin; Hu, Li-sha; Fan, Li-mei; Wang, Min; Feng, Xi-yun; Liu, Jin-tao; Zhao, Zhong-ming

    2013-04-01

    To investigate the epidemiological status of glucose-6-phosphate dehydrogenase (G6PD) deficiency among children from Yunnan with unique ethnic origins. DNA samples from 11759 children were tested with fluorescent spot test, G6PD/6PGD quantitative ratio assay and hemoglobin electrophoresis. The detection rate of G6PD deficiency was 2.5%, for which boys were significantly greater than girls (3.5% vs. 1.4%, P<0.05). Significant differences were also detected among children from different ethnic groups and different regions. For ethnic Han Chinese, the detection rate was 0.7%, which was lower than the majority of ethnic minorities. By regression analysis, altitude of residence and family history both have significant influence on the calculated rate. Occurrence of G6PD deficiency seems to be influenced by gender. It also varies substantially between different ethnic groups as well as regions, e.g., more common in south. It also showed a declining trend after years of diagnosis and intervention. This survey may provide a valuable basis for counseling of G6PD deficiency in Yunnan.

  15. A comparison of two collection methods for estimating abundance and parity of Anopheles albimanus in breeding sites and villages of southern Mexico.

    PubMed

    Ulloa, A; Rodríguez, M H; Rodríguez, A D; Roberts, D R

    1997-09-01

    The abundance and age structure of Anopheles albimanus populations were estimated by UV updraft light traps and human landing catches within villages and in nearby breeding sites of southern México. Four villages and 5 breeding sites were selected for the study. Light trap and human landing catches were simultaneously carried out in each breeding site and each village. Anopheles albimanus was the most abundant malaria vector caught in breeding sites and in villages. Significant differences in overall An. albimanus abundance among villages and among breeding sites were detected only by human landing catches. In both villages and breeding sites, more mosquitoes were captured by 1 human bait (34.3 +/- 6.3 and 14.6 +/- 2.9, respectively) than by one light trap (15.9 +/- 3.3 and 2.4 +/- 0.3 respectively) collection. After pooling, no significant differences were detected in the abundance estimated by each method in breeding sites and villages. A significant correlation of numbers of specimens between methods was detected. Age structure was different between samples from breeding sites and villages, with more gravid females collected in breeding sites, whereas more nulipars were collected in villages. By collection method, age structure was also different both in breeding sites and in villages. In breeding sites, the percentage of parous females was significantly higher in human landing catches, whereas the percentage of gravid females was significantly higher in light traps. In villages, only the percentage of gravid females was significantly higher in light traps. Our results suggests that UV light traps could be used to measure several entomological parameters of An. albimanus populations because both abundance variations and parity rates were similarly detected by both methods.

  16. Eye blink detection for different driver states in conditionally automated driving and manual driving using EOG and a driver camera.

    PubMed

    Schmidt, Jürgen; Laarousi, Rihab; Stolzmann, Wolfgang; Karrer-Gauß, Katja

    2018-06-01

    In this article, we examine the performance of different eye blink detection algorithms under various constraints. The goal of the present study was to evaluate the performance of an electrooculogram- and camera-based blink detection process in both manually and conditionally automated driving phases. A further comparison between alert and drowsy drivers was performed in order to evaluate the impact of drowsiness on the performance of blink detection algorithms in both driving modes. Data snippets from 14 monotonous manually driven sessions (mean 2 h 46 min) and 16 monotonous conditionally automated driven sessions (mean 2 h 45 min) were used. In addition to comparing two data-sampling frequencies for the electrooculogram measures (50 vs. 25 Hz) and four different signal-processing algorithms for the camera videos, we compared the blink detection performance of 24 reference groups. The analysis of the videos was based on very detailed definitions of eyelid closure events. The correct detection rates for the alert and manual driving phases (maximum 94%) decreased significantly in the drowsy (minus 2% or more) and conditionally automated (minus 9% or more) phases. Blinking behavior is therefore significantly impacted by drowsiness as well as by automated driving, resulting in less accurate blink detection.

  17. Musicians Are Better than Non-musicians in Frequency Change Detection: Behavioral and Electrophysiological Evidence

    PubMed Central

    Liang, Chun; Earl, Brian; Thompson, Ivy; Whitaker, Kayla; Cahn, Steven; Xiang, Jing; Fu, Qian-Jie; Zhang, Fawen

    2016-01-01

    Objective: The objectives of this study were: (1) to determine if musicians have a better ability to detect frequency changes under quiet and noisy conditions; (2) to use the acoustic change complex (ACC), a type of electroencephalographic (EEG) response, to understand the neural substrates of musician vs. non-musician difference in frequency change detection abilities. Methods: Twenty-four young normal hearing listeners (12 musicians and 12 non-musicians) participated. All participants underwent psychoacoustic frequency detection tests with three types of stimuli: tones (base frequency at 160 Hz) containing frequency changes (Stim 1), tones containing frequency changes masked by low-level noise (Stim 2), and tones containing frequency changes masked by high-level noise (Stim 3). The EEG data were recorded using tones (base frequency at 160 and 1200 Hz, respectively) containing different magnitudes of frequency changes (0, 5, and 50% changes, respectively). The late-latency evoked potential evoked by the onset of the tones (onset LAEP or N1-P2 complex) and that evoked by the frequency change contained in the tone (the acoustic change complex or ACC or N1′-P2′ complex) were analyzed. Results: Musicians significantly outperformed non-musicians in all stimulus conditions. The ACC and onset LAEP showed similarities and differences. Increasing the magnitude of frequency change resulted in increased ACC amplitudes. ACC measures were found to be significantly different between musicians (larger P2′ amplitude) and non-musicians for the base frequency of 160 Hz but not 1200 Hz. Although the peak amplitude in the onset LAEP appeared to be larger and latency shorter in musicians than in non-musicians, the difference did not reach statistical significance. The amplitude of the onset LAEP is significantly correlated with that of the ACC for the base frequency of 160 Hz. Conclusion: The present study demonstrated that musicians do perform better than non-musicians in detecting frequency changes in quiet and noisy conditions. The ACC and onset LAEP may involve different but overlapping neural mechanisms. Significance: This is the first study using the ACC to examine music-training effects. The ACC measures provide an objective tool for documenting musical training effects on frequency detection. PMID:27826221

  18. Ecological monitoring of intertidal phytobenthic communities of the Basque Coast (N. Spain) following the Prestige oil spill.

    PubMed

    Díez, I; Secilla, A; Santolaria, A; Gorostiaga, J M

    2009-12-01

    Following the Prestige oil spill, six-monthly samplings (spring and autumn) of intertidal macroalgal assemblages were carried out from 2004 to 2006 in twelve locations along the Basque coast. Macroalgal species appeared to be little modified, but species richness, diversity, and algal cover were significantly lower in the first year of the study, so it cannot be ruled out that the arrival of oil on the Basque coast might have had a damaging effect on intertidal communities. On the other hand, no significant differences were detected between locations slightly and moderately affected by oil in any of the structural parameters considered. By contrast, significant differences were detected between locations within each oiling level that indicate that other natural environmental factors play a greater role in the differences between locations than the oiling level. Likewise, significant differences were detected between areas within each location which were not consistent with time, indicating that communities are highly heterogeneous in species richness, diversity and algal cover at the scale of tens of meters. The dominant Corallina elongata and most of the accompanying species did not show significant year-on-year differences in terms of cover. Also, there were no differences between the two oiling levels. Analyses revealed a high spatial variability at the scale of kilometers (locations) and tens of meters (areas) for most of the taxa. The results obtained provide detailed quantitative data on intertidal phytobenthic assemblages of the Basque coast at different spatial and temporal scales that were hitherto unavailable for the region.

  19. The study on clinical value of the detection about serum and Unconjugated Bilirubin in diagnosis of neonatal jaundice.

    PubMed

    Wang, Guangzhou; Wang, Jiefei; Huang, Nannan; Yu, Fengqin

    2016-01-01

    In this paper, the clinical value of the detection about serum and unconjugated bilirubin (UCB) in neonatal jaundice was studied to found an effective and rapid method for diagnose of neonatal jaundice. ALB (Serum Albumin), total serum bilirubin (TSB) and UCB were detected by ELISA method among the 100 cases with neonatal jaundice selected for the study. The values of ALB, UCB and TSB in moderate jaundice patients were (42.83±3.87) g/L, (287.35±44.38) μm/L, (304.16±43.40) μm/L, respectively; as for the severe jaundice patients, the values were (38.41±4.82) g/L, (354.38±48.75) μm/L, (375.20±47.51) μm/L. The results showed significant differences with the p< 0.05 between moderate and severe jaundice patients. The level of ALB, UCB, TSB in hemolytic jaundice, obstructive jaundice and jaundice caused by other infections also had significant differences, and the difference was statistically significant (p<0.05). The detection of ALB and UCB provides a useful method for the diagnosis and assessment of neonatal jaundice.

  20. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review.

    PubMed

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

  1. Detection of survivin, carcinoembryonic antigen and ErbB2 level in oral squamous cell carcinoma patients.

    PubMed

    Li, Shu-Xia; Yang, Yan-Qi; Jin, Li-Jian; Cai, Zhi-Gang; Sun, Zheng

    2016-01-01

    The aim of this study was to detect the survivin, carcinoembryonic antigen (CEA) and ErbB2 in the saliva, serum and local tumor-exfoliated cells of oral squamous cell carcinoma (OSCC) patients, for providing reliable tumor markers for the early detection of oral malignant cancer. The saliva, serum, and local tumor-exfoliated cell samples of 26 OSCC patients without chemotherapy and 10 non-cancer patients were collected in Department of Oral and Maxillofacial Surgery, School of Stomatology, Peking University. The contents of survivin, CEA and ErbB2 using were detected usingenzyme-linked immunosorbent assay. The survivin and CEA levels in saliva and local tumor-exfoliated cells of OSCC patients were significantly higher than those in the non-cancer patients (P < 0.05), but there was no significant difference in the content of the above factors in the serum sample between two groups. There was no significant difference in the ErbB2 content in the saliva, serum or local tumor-exfoliated cells between two groups. Survivin and CEA levels are significantly increased in the saliva and local tumor-exfoliated cells in OSCC patients, and they can be used as reliable markers for the early detection of oral malignant cancer.

  2. Two-sample discrimination of Poisson means

    NASA Technical Reports Server (NTRS)

    Lampton, M.

    1994-01-01

    This paper presents a statistical test for detecting significant differences between two random count accumulations. The null hypothesis is that the two samples share a common random arrival process with a mean count proportional to each sample's exposure. The model represents the partition of N total events into two counts, A and B, as a sequence of N independent Bernoulli trials whose partition fraction, f, is determined by the ratio of the exposures of A and B. The detection of a significant difference is claimed when the background (null) hypothesis is rejected, which occurs when the observed sample falls in a critical region of (A, B) space. The critical region depends on f and the desired significance level, alpha. The model correctly takes into account the fluctuations in both the signals and the background data, including the important case of small numbers of counts in the signal, the background, or both. The significance can be exactly determined from the cumulative binomial distribution, which in turn can be inverted to determine the critical A(B) or B(A) contour. This paper gives efficient implementations of these tests, based on lookup tables. Applications include the detection of clustering of astronomical objects, the detection of faint emission or absorption lines in photon-limited spectroscopy, the detection of faint emitters or absorbers in photon-limited imaging, and dosimetry.

  3. Detection of proximal caries using digital radiographic systems with different resolutions.

    PubMed

    Nikneshan, Sima; Abbas, Fatemeh Mashhadi; Sabbagh, Sedigheh

    2015-01-01

    Dental radiography is an important tool for detection of caries and digital radiography is the latest advancement in this regard. Spatial resolution is a characteristic of digital receptors used for describing the quality of images. This study was aimed to compare the diagnostic accuracy of two digital radiographic systems with three different resolutions for detection of noncavitated proximal caries. Diagnostic accuracy. Seventy premolar teeth were mounted in 14 gypsum blocks. Digora; Optime and RVG Access were used for obtaining digital radiographs. Six observers evaluated the proximal surfaces in radiographs for each resolution in order to determine the depth of caries based on a 4-point scale. The teeth were then histologically sectioned, and the results of histologic analysis were considered as the gold standard. Data were entered using SPSS version 18 software and the Kruskal-Wallis test was used for data analysis. P <0.05 was considered as statistically significant. No significant difference was found between different resolutions for detection of proximal caries (P > 0.05). RVG access system had the highest specificity (87.7%) and Digora; Optime at high resolution had the lowest specificity (84.2%). Furthermore, Digora; Optime had higher sensitivity for detection of caries exceeding outer half of enamel. Judgment of oral radiologists for detection of the depth of caries had higher reliability than that of restorative dentistry specialists. The three resolutions of Digora; Optime and RVG access had similar accuracy in detection of noncavitated proximal caries.

  4. Clinical Performance of an Ultrahigh Resolution Chromosomal Microarray Optimized for Neurodevelopmental Disorders.

    PubMed

    Ho, Karen S; Twede, Hope; Vanzo, Rena; Harward, Erin; Hensel, Charles H; Martin, Megan M; Page, Stephanie; Peiffer, Andreas; Mowery-Rushton, Patricia; Serrano, Moises; Wassman, E Robert

    2016-01-01

    Copy number variants (CNVs) as detected by chromosomal microarray analysis (CMA) significantly contribute to the etiology of neurodevelopmental disorders, such as developmental delay (DD), intellectual disability (ID), and autism spectrum disorder (ASD). This study summarizes the results of 3.5 years of CMA testing by a CLIA-certified clinical testing laboratory 5487 patients with neurodevelopmental conditions were clinically evaluated for rare copy number variants using a 2.8-million probe custom CMA optimized for the detection of CNVs associated with neurodevelopmental disorders. We report an overall detection rate of 29.4% in our neurodevelopmental cohort, which rises to nearly 33% when cases with DD/ID and/or MCA only are considered. The detection rate for the ASD cohort is also significant, at 25%. Additionally, we find that detection rate and pathogenic yield of CMA vary significantly depending on the primary indications for testing, the age of the individuals tested, and the specialty of the ordering doctor. We also report a significant difference between the detection rate on the ultrahigh resolution optimized array in comparison to the array from which it originated. This increase in detection can significantly contribute to the efficient and effective medical management of neurodevelopmental conditions in the clinic.

  5. Musical experts recruit action-related neural structures in harmonic anomaly detection: Evidence for embodied cognition in expertise

    PubMed Central

    Sherwin, Jason; Sajda, Paul

    2013-01-01

    Humans are extremely good at detecting anomalies in sensory input. For example, while listening to a piece of Western-style music, an anomalous key change or an out-of-key pitch is readily apparent, even to the non-musician. In this paper we investigate differences between musical experts and non-experts during musical anomaly detection. Specifically, we analyzed the electroencephalograms (EEG) of five expert cello players and five non-musicians while they listened to excerpts of J.S. Bach’s Prelude from Cello Suite No.1. All subjects were familiar with the piece, though experts also had extensive experience playing the piece. Subjects were told that anomalous musical events (AMEs) could occur at random within the excerpts of the piece and were told to report the number of AMEs after each excerpt. Furthermore, subjects were instructed to remain still while listening to the excerpts and their lack of movement was verified via visual and EEG monitoring. Experts had significantly better behavioral performance (i.e. correctly reporting AME counts) than non-experts, though both groups had mean accuracies greater than 80%. These group differences were also reflected in the EEG correlates of key-change detection post-stimulus, with experts showing more significant, greater magnitude, longer periods of and earlier peaks in condition-discriminating EEG activity than novices. Using the timing of the maximum discriminating neural correlates, we performed source reconstruction and compared significant differences between cellists and non-musicians. We found significant differences that included a slightly right lateralized motor and frontal source distribution. The right lateralized motor activation is consistent with the cortical representation of the left hand – i.e. the hand a cellist would use, while playing, to generate the anomalous key-changes. In general, these results suggest that sensory anomalies detected by experts may in fact be partially a result of an embodied cognition, with a model of the action for generating the anomaly playing a role in its detection. PMID:24056235

  6. Metallothionein-I/II Knockout Mice Aggravate Mitochondrial Superoxide Production and Peroxiredoxin 3 Expression in Thyroid after Excessive Iodide Exposure

    PubMed Central

    Zhang, Na; Wang, Lingyan; Duan, Qi; Lin, Laixiang; Ahmed, Mohamed; Wang, Tingting; Yao, Xiaomei

    2015-01-01

    Purpose. We aim to figure out the effect of metallothioneins on iodide excess induced oxidative stress in the thyroid. Methods. Eight-week-old MT-I/II knockout (MT-I/II KO) mice and background-matched wild-type (WT) mice were used. Mitochondrial superoxide production and peroxiredoxin (Prx) 3 expression were measured. Results. In in vitro study, more significant increases in mitochondrial superoxide production and Prx 3 expression were detected in the MT-I/II KO groups. In in vivo study, significantly higher concentrations of urinary iodine level were detected in MT-I/II KO mice in 100 HI group. Compared to the NI group, there was no significant difference existing in serum thyroid hormones level in either groups (P > 0.05), while the mitochondrial superoxide production was significantly increased in 100 HI groups with significantly increased LDH activity and decreased relative cell viability. Compared to WT mice, more significant changes were detected in MT-I/II KO mice in 100 HI groups. No significant differences were detected between the NI group and 10 HI group in both the MT-I/II KO and WT mice groups (P > 0.05). Conclusions. Iodide excess in a thyroid without MT I/II protection may result in strong mitochondrial oxidative stress, which further leads to the damage of thyrocytes. PMID:26101557

  7. Comparison of different sampling techniques and of different culture methods for detection of group B streptococcus carriage in pregnant women.

    PubMed

    El Aila, Nabil A; Tency, Inge; Claeys, Geert; Saerens, Bart; Cools, Piet; Verstraelen, Hans; Temmerman, Marleen; Verhelst, Rita; Vaneechoutte, Mario

    2010-09-29

    Streptococcus agalactiae (group B streptococcus; GBS) is a significant cause of perinatal and neonatal infections worldwide. To detect GBS colonization in pregnant women, the CDC recommends isolation of the bacterium from vaginal and anorectal swab samples by growth in a selective enrichment medium, such as Lim broth (Todd-Hewitt broth supplemented with selective antibiotics), followed by subculture on sheep blood agar. However, this procedure may require 48 h to complete. We compared different sampling and culture techniques for the detection of GBS. A total of 300 swabs was taken from 100 pregnant women at 35-37 weeks of gestation. For each subject, one rectovaginal, one vaginal and one rectal ESwab were collected. Plating onto Columbia CNA agar (CNA), group B streptococcus differential agar (GBSDA) (Granada Medium) and chromID Strepto B agar (CA), with and without Lim broth enrichment, were compared. The isolates were confirmed as S. agalactiae using the CAMP test on blood agar and by molecular identification with tDNA-PCR or by 16S rRNA gene sequence determination. The overall GBS colonization rate was 22%. GBS positivity for rectovaginal sampling (100%) was significantly higher than detection on the basis of vaginal sampling (50%), but not significantly higher than for rectal sampling (82%). Direct plating of the rectovaginal swab on CNA, GBSDA and CA resulted in detection of 59, 91 and 95% of the carriers, respectively, whereas subculturing of Lim broth yielded 77, 95 and 100% positivity, respectively. Lim broth enrichment enabled the detection of only one additional GBS positive subject. There was no significant difference between GBSDA and CA, whereas both were more sensitive than CNA. Direct culture onto GBSDA or CA (91 and 95%) detected more carriers than Lim broth enrichment and subculture onto CNA (77%). One false negative isolate was observed on GBSDA, and three false positives on CA. In conclusion, rectovaginal sampling increased the number GBS positive women detected, compared to vaginal and/or rectal sampling. Direct plating on CA and/or GBSDA provided rapid detection of GBS that was at least as sensitive and specific as the CDC recommended method of Lim broth subcultured onto non chromogenic agar.

  8. Brain alcohol detectability in human subjects with and without a paternal history of alcoholism.

    PubMed

    Chiu, Tak-Ming; Mendelson, Jack H; Sholar, Michelle B; Mutschler, Nicole H; Wines, James D; Hesselbrock, Victor M; Mello, Nancy K

    2004-01-01

    This study examined the putative effects of a paternal history of alcoholism on the apparent detectability of brain alcohol in human subjects. Brain to blood ethanol ratios in two cohorts of men were determined, using proton magnetic resonance spectroscopic imaging in a brain voxel (2 x 2 x 2 cm) containing the putamen. The men were light drinkers with a positive (n = 8) or a negative (n = 8) paternal history of alcoholism and were given an alcohol dose of 0.8 g/kg body weight. In both groups, brain alcohol detectability was less than 100%. No significant difference (p = .37) was found in the brain/blood ethanol ratios of the two groups. However, subjective assessments of feeling the extreme effects of alcohol and the extent of intoxication ("how drunk") were highly correlated with a paternal history of alcoholism, with the paternal history negative group reporting significantly more intense feelings of intoxication. A review of existing literature evidence and data obtained in this study indicate that brain alcohol detectability via magnetic resonance spectroscopic imaging is less than 100%. There were no significant differences in brain alcohol detectability between paternal history positive and paternal history negative men. Differences in the Subjective High Assessment Scale ratings between the two groups, however, indicate the importance of a genetic influence on the subjective response to alcohol.

  9. Diagnostic accuracy of a five-point Likert scoring system for magnetic resonance imaging (MRI) evaluated according to results of MRI/ultrasonography image-fusion targeted biopsy of the prostate.

    PubMed

    Shin, Toshitaka; Smyth, Thomas B; Ukimura, Osamu; Ahmadi, Nariman; de Castro Abreu, Andre Luis; Ohe, Chisato; Oishi, Masakatsu; Mimata, Hiromitsu; Gill, Inderbir S

    2018-01-01

    To evaluate the accuracy of a magnetic resonance imaging (MRI)-based Likert scoring system in the detection of clinically significant prostate cancer (CSPC), using MRI/ultrasonography (US) image-fusion targeted biopsy (FTB) as a reference standard. We retrospectively reviewed 1218 MRI-detected lesions in 629 patients who underwent subsequent MRI/US FTB between October 2012 and August 2015. 3-Tesla MRI was independently reported by one of eight radiologists with varying levels of experience and scored on a five-point Likert scale. All lesions with Likert scores 1-5 were prospectively defined as targets for MRI/US FTB. CSPC was defined as Gleason score ≥7. The median patient age was 64 years, PSA level 6.97 ng/mL and estimated prostate volume 52.2 mL. Of 1218 lesions, 48% (n = 581) were rated as Likert 1-2, 35% (n = 428) were Likert 3 and 17% (n = 209) were Likert 4-5. For Likert scores 1-5, the overall cancer detection rates were 12%, 13%, 22%, 50% and 59%, respectively, and the CSPC detection rates were 4%, 4%, 12%, 33% and 48%, respectively. Grading using the five-point scale showed strong positive correlation with overall cancer detection rate (r = 0.949, P = 0.05) and CSPC detection rate (r = 0.944, P = 0.05). By comparison, in Likert 4-5 lesions, significant differences were noted in overall cancer detection rate (63% vs 35%; P = 0.001) and CSPC detection rate (47% vs 29%; P = 0.027) for the more experienced vs the less experienced radiologists. The detection rates of overall cancer and CSPC strongly correlated with the five-point grading of the Likert scale. Among radiologists with different levels of experience, there were significant differences in these cancer detection rates. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  10. [Use of MRI before biopsy in diagnosis of prostate cancer: Single-operator study].

    PubMed

    Bassard, S; Mege, J-L

    2015-12-01

    The diagnostic for prostate cancer is changing. To improve the detection of this cancer, urologists expect a lot from the contribution of magnetic resonance imaging (MRI). What is the role of this imaging in prostate cancer detection? This is a retrospective study, from 2011 to 2013, mono-centric and single-operator. Of the 464 needle biopsy of the prostate (BP), we excluded those with PSA>20 ng/mL or digital rectal examination (DRE)>T3. The remaining 430 BP were submitted or not to a 1.5 tesla MRI with pelvic antenna. The primary aim is the overall detection of prostate cancer. Secondary aim was the detection rate during the first series of BP and repeat BP, between the two groups in the MRI group. MRI and MRI without populations are comparable for age (63.3 vs 64.6), PSA (6.10 vs 6.13), DRE>T1c, prostate volume (55.4 cm(3) vs 51.7 cm(3)). There is no significant difference in overall detection between the two groups (P=0.12). There is no significant difference in cancer detection between the first BP (P=0.13) and the repeat BP (P=0.07). There is a significant difference in the early detection of BP MRI group (P=0.03) but not for the BP repeat MRI group (P=0.07). For 108 BP iterative MRI group, there were 67 BP targeted "mentally" with MRI: 18 cancers were detected, making a 25% detection rate. This study helps to highlight the value of MRI in the early rounds of BP but we can ask the value of this imaging during repeat biopsies. Targeted biopsies "mentally" do not have the expected detection sensitivity and seems to require a three-dimensional reconstruction to be more effective. 5. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  11. Origin and Processing Methods Slightly Affect Allergenic Characteristics of Cashew Nuts (Anacardium occidentale).

    PubMed

    Reitsma, Marit; Bastiaan-Net, Shanna; Sijbrandij, Lutske; de Weert, Evelien; Sforza, Stefano; Gerth van Wijk, Roy; Savelkoul, Huub F J; de Jong, Nicolette W; Wichers, Harry J

    2018-04-01

    The protein content and allergen composition was studied of cashews from 8 different origins (Benin, Brazil, Ghana, India, Ivory Coast, Mozambique, Tanzania, Vietnam), subjected to different in-shell heat treatments (steamed, fried, drum-roasted). On 2D electrophoresis, 9 isoforms of Ana o 1, 29 isoforms of Ana o 2 (11 of the acidic subunit, 18 of the basic subunit), and 8 isoforms of the large subunit of Ana o 3 were tentatively identified. Based on 1D and 2D electrophoresis, no difference in allergen content (Ana o 1, 2, 3) was detected between the cashews of different origins (P > 0.5), some small but significant differences were detected in allergen solubility between differently heated cashews. No major differences in N- and C-terminal microheterogeneity of Ana o 3 were detected between cashews of different origins. Between the different heat treatments, no difference was detected in glycation, pepsin digestibility, or IgE binding of the cashew proteins. © 2018 Institute of Food Technologists®.

  12. Spatial Mechanisms within the Dorsal Visual Pathway Contribute to the Configural Processing of Faces.

    PubMed

    Zachariou, Valentinos; Nikas, Christine V; Safiullah, Zaid N; Gotts, Stephen J; Ungerleider, Leslie G

    2017-08-01

    Human face recognition is often attributed to configural processing; namely, processing the spatial relationships among the features of a face. If configural processing depends on fine-grained spatial information, do visuospatial mechanisms within the dorsal visual pathway contribute to this process? We explored this question in human adults using functional magnetic resonance imaging and transcranial magnetic stimulation (TMS) in a same-different face detection task. Within localized, spatial-processing regions of the posterior parietal cortex, configural face differences led to significantly stronger activation compared to featural face differences, and the magnitude of this activation correlated with behavioral performance. In addition, detection of configural relative to featural face differences led to significantly stronger functional connectivity between the right FFA and the spatial processing regions of the dorsal stream, whereas detection of featural relative to configural face differences led to stronger functional connectivity between the right FFA and left FFA. Critically, TMS centered on these parietal regions impaired performance on configural but not featural face difference detections. We conclude that spatial mechanisms within the dorsal visual pathway contribute to the configural processing of facial features and, more broadly, that the dorsal stream may contribute to the veridical perception of faces. Published by Oxford University Press 2016.

  13. Evaluation of the efficiency of three extraction conditions for the immunochemical detection of allergenic soy proteins in different food matrices.

    PubMed

    Amponsah, Amma; Nayak, Balunkeswar

    2018-04-01

    Recent studies have shown the need to improve soy allergen extraction using different extraction conditions to ensure more accurate results in allergen detection. This study investigated some of these extraction conditions to confirm that these methods, especially ultrasound-assisted extraction (UAE) and the use of Laemmli buffer instead of the conventional extraction with phosphate-buffered saline (PBS), could be helpful in improving the extraction step in allergen detection. Higher total soluble protein was obtained in all samples extracted with Laemmli buffer alone and in combination with ultrasound. For immunochemical detection of soy proteins by enzyme-linked immunosorbent assay (ELISA), comparable detection was observed in extracts from all extraction conditions in all commercial samples with the exception of table cracker and veggie burger, where significantly higher detection was seen in extracts from Laemmli buffer only. For the dry mix and cookie samples, the degree of soy protein detection with ELISA varied among the different extraction conditions, but overall, extraction with only Laemmli buffer showed higher detection. Laemmli buffer with conventional extraction and UAE may be better alternatives or additional extraction methods in soy allergen detection. Different food matrices performed differently (whether it was for the recovery of total proteins or detection by ELISA) under different extraction conditions. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  14. Sputum, sex and scanty smears: new case definition may reduce sex disparities in smear-positive tuberculosis.

    PubMed

    Ramsay, A; Bonnet, M; Gagnidze, L; Githui, W; Varaine, F; Guérin, P J

    2009-05-01

    Urban clinic, Nairobi. To evaluate the impact of specimen quality and different smear-positive tuberculosis (TB) case (SPC) definitions on SPC detection by sex. Prospective study among TB suspects. A total of 695 patients were recruited: 644 produced > or =1 specimen for microscopy. The male/female sex ratio was 0.8. There were no significant differences in numbers of men and women submitting three specimens (274/314 vs. 339/380, P = 0.43). Significantly more men than women produced a set of three 'good' quality specimens (175/274 vs. 182/339, P = 0.01). Lowering thresholds for definitions to include scanty smears resulted in increases in SPC detection in both sexes; the increase was significantly higher for women. The revised World Health Organization (WHO) case definition was associated with the highest detection rates in women. When analysis was restricted only to patients submitting 'good' quality specimen sets, the difference in detection between sexes was on the threshold for significance (P = 0.05). Higher SPC notification rates in men are commonly reported by TB control programmes. The revised WHO SPC definition may reduce sex disparities in notification. This should be considered when evaluating other interventions aimed at reducing these. Further study is required on the effects of the human immuno-deficiency virus and instructed specimen collection on sex-specific impact of new SPC definition.

  15. A new measure for the assessment of visual awareness in individuals with tunnel vision.

    PubMed

    AlSaqr, Ali M; Dickinson, Chris M

    2017-01-01

    Individuals with a restricted peripheral visual field or tunnel vision (TV) have problems moving about and avoiding obstacles. Some individuals adapt better than others and some use assistive optical aids, so measurement of the visual field is not sufficient to describe their performance. In the present study, we developed a new clinical test called the 'Assessment of Visual Awareness (AVA)', which can be used to measure detection of peripheral targets. The participants were 20 patients with TV due to retinitis pigmentosa (PTV) and 50 normally sighted participants with simulated tunnel vision (STV) using goggles. In the AVA test, detection times were measured, when subjects searched for 24 individually presented, one degree targets, randomly positioned in a 60 degrees noise background. Head and eye movements were allowed and the presentation time was unlimited. The test validity was investigated by correlating the detection times with the 'percentage of preferred walking speed' (PPWS) and the 'number of collisions' on an indoor mobility course. In PTV and STV, the detection times had significant negative correlation with the field of view. The detection times had significant positive relations with target location. In the STV, the detection time was significantly negatively correlated with the PPWS and significantly positively correlated with the collisions score on the indoor mobility course. In the PTV, the relationship was not statistically significant. No significant difference in performance of STV was found when repeating the test one to two weeks later. The proposed AVA test was sensitive to the field of view and target location. The test is unique in design, quick, simple to deliver and both repeatable and valid. It could be a valuable tool to test different rehabilitation strategies in patients with TV. © 2016 Optometry Australia.

  16. MRI/US fusion-guided prostate biopsy allows for equivalent cancer detection with significantly fewer needle cores in biopsy-naive men

    PubMed Central

    Yarlagadda, Vidhush K.; Lai, Win Shun; Gordetsky, Jennifer B.; Porter, Kristin K.; Nix, Jeffrey W.; Thomas, John V.; Rais-Bahrami, Soroush

    2018-01-01

    PURPOSE We aimed to investigate the efficiency and cancer detection of magnetic resonance imaging (MRI)/ultrasonography (US) fusion-guided prostate biopsy in a cohort of biopsy-naive men compared with standard-of-care systematic extended sextant transrectal ultrasonography (TRUS)-guided biopsy. METHODS From 2014 to 2016, 72 biopsy-naive men referred for initial prostate cancer evaluation who underwent MRI of the prostate were prospectively evaluated. Retrospective review was performed on 69 patients with lesions suspicious for malignancy who underwent MRI/US fusion-guided biopsy in addition to systematic extended sextant biopsy. Biometric, imaging, and pathology data from both the MRI-targeted biopsies and systematic biopsies were analyzed and compared. RESULTS There were no significant differences in overall prostate cancer detection when comparing MRI-targeted biopsies to standard systematic biopsies (P = 0.39). Furthermore, there were no significant differences in the distribution of severity of cancers based on grade groups in cases with cancer detection (P = 0.68). However, significantly fewer needle cores were taken during the MRI/US fusion-guided biopsy compared with systematic biopsy (63% less cores sampled, P < 0.001) CONCLUSION In biopsy-naive men, MRI/US fusion-guided prostate biopsy offers equal prostate cancer detection compared with systematic TRUS-guided biopsy with significantly fewer tissue cores using the targeted technique. This approach can potentially reduce morbidity in the future if used instead of systematic biopsy without sacrificing the ability to detect prostate cancer, particularly in cases with higher grade disease. PMID:29770762

  17. Whole body vibration versus magnetic therapy on bone mineral density in elderly osteoporotic individuals.

    PubMed

    Shanb, Alsayed Abdelhameed; Youssef, Enas Fawzy; Muaidi, Qassim Ibrahim; Alothman, Abdullah Ahmed

    2017-08-03

    Osteoporosis usually develops gradually and progresses without significant signs and symptoms. It is one of the most common musculoskeletal conditions associated with aging. To evaluate the effects of whole body vibration (WBV) or magnetic therapy in addition to standard pharmacological treatment on bone mineral density (BMD) in elderly individuals being treated for osteoporosis. Eighty-five participants, 60-75 years of age, were randomly divided into three groups. All three groups received the same standard pharmacological treatment comprised of vitamin D, calcium, and alendronate sodium. In Group I, thirty participants were also exposed to WBV for 25 minutes in each session with two sessions per week for 4 months. In Group II, thirty participants were exposed to magnetic therapy for 50 minutes in each session with two sessions per week for 4 months. In Group III, twenty-five participants received only pharmacological treatment. Dual-energy X-ray absorptiometry was used to measure BMD of the lumbar spine and femoral heads before and after interventions. Venus blood sample was drawn for analysis of calcium and vitamin D. An ANOVA test detected significant (p< 0.05) differences in BMD after treatment among the three groups with no significant difference was detected between patients receiving WBV and magnetic therapy. Statistical t-tests detected significant (p< 0.05) increases in BMD after application of WBV or magnetic therapy in combination with pharmacological treatment, but no significant increase after pharmacological treatment alone. Addition of either WBV or magnetic therapy to standard pharmacological treatment for osteoporosis significantly increased BMD in elderly subjects. No significant difference in effectiveness was detected between these two alternative therapy modalities. Consequently, either WBV or magnetic therapy could be effectively applied in conjunction with pharmacological treatment to increase BMD in elderly osteoporotic patients.

  18. Multispectral detection of cutaneous lesions using spectroscopy and microscopy approaches

    NASA Astrophysics Data System (ADS)

    Borisova, E.; Genova-Hristova, Ts.; Troyanova, P.; Pavlova, E.; Terziev, I.; Semyachkina-Glushkovskaya, O.; Lomova, M.; Genina, E.; Stanciu, G.; Tranca, D.; Avramov, L.

    2018-02-01

    Autofluorescence, diffuse-reflectance and transmission spectral, and microscopic measurements were made on different cutaneous neoplastic lesions, namely basal cell carcinoma, squamous cell carcinoma, malignant melanoma, and dysplastic and benign lesions related. Spectroscopic measurements were made on ex vivo tissue samples, and confocal microscopy investigations were made on thin tissue slices. Fluorescence spectra obtained reveal statistically significant differences between the different benign, dysplastic and malignant lesions by the level of emission intensity, as well by spectral shape, which are fingerprints applicable for differentiation algorithms. In reflectance mode the most significant differences are related to the influence of skin pigments - melanin and hemoglobin. Transmission spectroscopy mode gave complementary optical properties information about the tissue samples investigated to that one of reflectance and absorption spectroscopy. Using autofluorescence detection of skin lesions we obtain very good diagnostic performance for distinguishing of nonmelanoma lesions. Using diffuse reflectance and transmission spectroscopy we obtain significant tool for pigmented pathologies differentiation, but it is a tool with moderate sensitivity for non-melanoma lesions detection. One could rapidly increase the diagnostic accuracy of the received combined "optical biopsy" method when several spectral detection techniques are applied in common algorithm for lesions' differentiation. Specific spectral features observed in each type of lesion investigated on micro and macro level would be presented and discussed. Correlation between the spectral data received and the microscopic features observed would be discussed in the report.

  19. Resistance to antimicrobial agents among Salmonella isolates recovered from layer farms and eggs in the Caribbean region.

    PubMed

    Adesiyun, Abiodun; Webb, Lloyd; Musai, Lisa; Louison, Bowen; Joseph, George; Stewart-Johnson, Alva; Samlal, Sannandan; Rodrigo, Shelly

    2014-12-01

    This investigation determined the frequency of resistance of 84 isolates of Salmonella comprising 14 serotypes recovered from layer farms in three Caribbean countries (Trinidad and Tobago, Grenada, and St. Lucia) to eight antimicrobial agents, using the disc diffusion method. Resistance among isolates of Salmonella was related to the country of recovery, type of sample, size of layer farms, and isolate serotype. Overall, all (100.0%) of the isolates exhibited resistance to one or more of seven antimicrobial agents tested, and all were susceptible to chloramphenicol. The resistance detected ranged from 11.9% to sulphamethoxazole-trimethoprim (SXT) to 100.0% to erythromycin. The difference was, however, not statistically significant (P = 0.23). Across countries, for types of samples that yielded Salmonella, significant differences in frequency of resistance were detected only to SXT (P = 0.002) in Trinidad and Tobago and to gentamycin (P = 0.027) in St. Lucia. For the three countries, the frequency of resistance to antimicrobial agents was significantly different for ampicillin (P = 0.001) and SXT (P = 0.032). A total of 83 (98.8%) of the 84 isolates exhibited 39 multidrug resistance patterns. Farm size significantly (P = 0.032) affected the frequency of resistance to kanamycin across the countries. Overall, among the 14 serotypes of Salmonella tested, significant (P < 0.05) differences in frequency of resistance were detected to kanamycin, ampicillin, and SXT. Results suggest that the relatively high frequency of resistance to six of the antimicrobial agents (erythromycin, streptomycin, gentamycin, kanamycin, ampicillin, and tetracycline) tested and the multidrug resistance detected may pose prophylactic and therapeutic concerns for chicken layer farms in the three countries studied.

  20. Steganography Detection Using Entropy Measures

    DTIC Science & Technology

    2012-11-16

    latter leads to the level of compression of the image . 3.3. Least Significant Bit ( LSB ) The object of steganography is to prevent suspicion upon the...structured user interface developer tools. Steganography Detection Using Entropy Measures Technical Report By Eduardo Meléndez Universidad Politécnica de ...6 2.3. Different kinds of steganography . . . . . . . . . . . . . . . . . . . . . 6 II. Steganography 8 3. Images and Significance of

  1. Profile of Some Trace Elements in the Liver of Camels, Sheep, and Goats in the Sudan

    PubMed Central

    Ibrahim, Ibrahim Abdullah; Shamat, Ali Mahmoud; Hussien, Mohammed Osman; El Hussein, Abdel Rahim Mohammed

    2013-01-01

    One hundred camels (Camelus dromedaries) and fifty sheep and goats being adult, male, and apparently healthy field animals were studied to provide data regarding the normal values of some hepatic trace elements. Liver samples were collected during postmortem examination, digested, and analyzed for Cu, Zn, Fe, Co, and Mn using atomic absorption spectrophotometry. The results showed that the differences in mean liver concentrations of Cu, Zn, Fe, and Co between camels, sheep, and goats were statistically significant (P < 0.05). Hepatic Cu, Fe, and Co concentrations were higher in camels than in sheep and goats. All liver samples were adequate for Fe and Co, whereas only camel liver was adequate for Cu. In camels, hepatic Zn concentration was inadequately lower than that in sheep and goats. No difference in Mn concentration was detected between camels, sheep, and goats. All liver samples were inadequate compared to free-ranging herbivores. In camels, significant correlation (r 2 = −0.207, P value = 0.04) was detected between Zn and Co, whereas in sheep significant correlation (r 2 = −0.444, P value = 0.026) was detected between Zn and Mn. No significant correlation between trace elements was detected in goats. PMID:26464909

  2. Predictors of detection of alcohol use episodes using a transdermal alcohol sensor.

    PubMed

    Barnett, Nancy P; Meade, E B; Glynn, Tiffany R

    2014-02-01

    The objective of this investigation was to establish the ability of the Secure Continuous Remote Alcohol Monitoring (SCRAM) alcohol sensor to detect different levels of self-reported alcohol consumption, and to determine whether gender and body mass index, alcohol dependence, bracelet version, and age of bracelet influenced detection of alcohol use. Heavy drinking adults (N = 66, 46% female) wore the SCRAM for 1-28 days and reported their alcohol use in daily Web-based surveys. Participant reports of alcohol use were matched with drinking episodes identified from bracelet readings. On days when bracelets were functional, 690 drinking episodes were reported and 502 of those episodes (72.8%) were detected using sensor data. Using generalized estimating equations, we found no gender differences in detection of reported drinking episodes (77% for women, 69% for men). In univariate analyses, at the level of fewer than 5 drinks, women's episodes were more likely to be detected, likely because of the significantly higher transdermal alcohol concentration levels of these episodes, whereas at the level of 5 or more drinks, there was no gender difference in detection (92.6% for women, 93.4% for men). In multivariable analyses, no variables other than number of drinks significantly predicted alcohol detection. In summary, the SCRAM sensor is very good at detecting 5 or more drinks; performance of the monitor below this level was better among women because of their higher transdermal alcohol concentration levels. Individual person characteristics and bracelet features were not related to detection after number of drinks was included. Minimal bracelet malfunctions were noted.

  3. Predictors of Detection of Alcohol Use Episodes Using a Transdermal Alcohol Sensor

    PubMed Central

    Barnett, Nancy P.; Meade, E.B.; Glynn, Tiffany R.

    2014-01-01

    The objective of this investigation was to establish the ability of the Secure Continuous Remote Alcohol Monitoring (SCRAM) alcohol sensor to detect different levels of self-reported alcohol consumption, and to determine whether gender and body mass index, alcohol dependence, bracelet version, and age of bracelet influenced detection of alcohol use. Method Heavy drinking adults (N = 66; 46% female) wore the SCRAM for 1–28 days and reported their alcohol use in daily web-based surveys. Participant reports of alcohol use were matched with drinking episodes identified from bracelet readings. Results On days when bracelets were functional, 690 drinking episodes were reported and 502 of those episodes (72.8%) were detected using sensor data. Using Generalized Estimating Equations, we found no gender differences in detection of reported drinking episodes (77% for women, 69% for men). In univariate analyses, at the level of fewer than five drinks, women’s episodes were more likely to be detected, likely due to the significantly higher TAC levels of these episodes, whereas at the level of five or more drinks, there was no gender difference in detection (92.6% for women, 93.4% of men’s). In multivariable analyses, no variables other than number of drinks significantly predicted alcohol detection. Conclusion The SCRAM sensor is very good at detecting five or more drinks; performance of the monitor below this level was better among women due to their higher TAC levels. Individual person characteristics and bracelet features were not related to detection after number of drinks was included. Minimal bracelet malfunctions were noted. PMID:24490713

  4. Chinese Radical Detection Also Depends on Linguistic Role

    ERIC Educational Resources Information Center

    Greenberg, Seth N.; Chuan, Vince

    2010-01-01

    This study tests whether the linguistic role of a character in Chinese text affects detection of its constituent radicals. Linguistic role or status of an embedding context (e.g., word) has been shown to affect detection of embedded constituent units (e.g., letters) when reading alphabetic texts. Given significant differences between alphabetic…

  5. ROC evaluation of SPECT myocardial lesion detectability with and without single iteration non-uniform Chang attenuation compensation using an anthropomorphic female phantom

    NASA Astrophysics Data System (ADS)

    Jang, Sunyoung; Jaszczak, R. J.; Tsui, B. M. W.; Metz, C. E.; Gilland, D. R.; Turkington, T. G.; Coleman, R. E.

    1998-08-01

    The purpose of this work was to evaluate lesion detectability with and without nonuniform attenuation compensation (AC) in myocardial perfusion SPECT imaging in women using an anthropomorphic phantom and receiver operating characteristics (ROC) methodology. Breast attenuation causes artifacts in reconstructed images and may increase the difficulty of diagnosis of myocardial perfusion imaging in women. The null hypothesis tested using the ROC study was that nonuniform AC does not change the lesion detectability in myocardial perfusion SPECT imaging in women. The authors used a filtered backprojection (FBP) reconstruction algorithm and Chang's (1978) single iteration method for AC. In conclusion, with the authors' proposed myocardial defect model nuclear medicine physicians demonstrated no significant difference for the detection of the anterior wall defect; however, a greater accuracy for the detection of the inferior wall defect was observed without nonuniform AC than with it (P-value=0.0034). Medical physicists did not demonstrate any statistically significant difference in defect detection accuracy with or without nonuniform AC in the female phantom.

  6. Surface regions of illusory images are detected with a slower processing speed than those of luminance-defined images.

    PubMed

    Mihaylova, Milena; Manahilov, Velitchko

    2010-11-24

    Research has shown that the processing time for discriminating illusory contours is longer than for real contours. We know, however, little whether the visual processes, associated with detecting regions of illusory surfaces, are also slower as those responsible for detecting luminance-defined images. Using a speed-accuracy trade-off (SAT) procedure, we measured accuracy as a function of processing time for detecting illusory Kanizsa-type and luminance-defined squares embedded in 2D static luminance noise. The data revealed that the illusory images were detected at slower processing speed than the real images, while the points in time, when accuracy departed from chance, were not significantly different for both stimuli. The classification images for detecting illusory and real squares showed that observers employed similar detection strategies using surface regions of the real and illusory squares. The lack of significant differences between the x-intercepts of the SAT functions for illusory and luminance-modulated stimuli suggests that the detection of surface regions of both images could be based on activation of a single mechanism (the dorsal magnocellular visual pathway). The slower speed for detecting illusory images as compared to luminance-defined images could be attributed to slower processes of filling-in of regions of illusory images within the dorsal pathway.

  7. Social Eavesdropping: Can You Hear the Emotionality in a "Hello" That Is Not Meant for You?

    PubMed

    Karthikeyan, Sethu; Ramachandra, Vijayachandra

    2017-01-01

    The study examined third-party listeners' ability to detect the Hellos spoken to prevalidated happy, neutral, and sad facial expressions. The average detection accuracies from the happy and sad (HS), happy and neutral (HN), and sad and neutral (SN) listening tests followed the average vocal pitch differences between the two sets of Hellos in each of the tests; HS and HN detection accuracies were above chance reflecting the significant pitch differences between the respective Hellos. The SN detection accuracy was at chance reflecting the lack of pitch difference between sad and neutral Hellos. As expected, the SN detection accuracy positively correlated with theory of mind; participating in these tests has been likened to the act of eavesdropping, which has been discussed from an evolutionary perspective. An unexpected negative correlation between the HS detection accuracy and the empathy quotient has been discussed with respect to autism research on empathy and pitch discrimination.

  8. A prospective study: Is handheld micropower impulse radar technology (Pneumoscan) a promising method to detect pneumothorax?

    PubMed

    Hocagil, Hilal; Hocagil, Abdullah Cüneyt; Karacabey, Sinan; Akkaya, Tuğba; Şimşek, Gözde; Sanrı, Erkman

    2015-09-01

    This study aimed to discuss the effectiveness of Pneumoscan working with micropower impulse radar (MIR) technology in diagnosing pneumothorax (PTX) in the emergency department. Patients with suspicion of PTX and indication for thorax tomography (CT) were included into the study. Findings of the Thorax CT were compared with the results of Pneumoscan. Chi-square and Fisher's exact tests were used in categorical variables. One hundred and fifteen patients were included into the study group; twelve patients presented with PTX diagnosed by CT, 10 of which were detected by Pneumoscan. Thirty-six true negative results, sixty-seven false positive results, and two false negative results were obtained, which resulted in an overall sensitivity of 83.3%, specificity of 35.0% for Pneumoscan. There was no statistically significant difference between the effectiveness of Pneumoscan and CT on the detection of PTX (p=0.33). There was no difference between the size of PTX diagnosed by CT and PTX diagnosed by Pneumoscan (p=0.47). There was no statistically significant difference between Pneumoscan and CT on detecting the localisation of the PTX (p=1.00). For the 10 cases diagnosed by Pneumoscan, mean chest wall thickness was determined as 50.3 mm while mean chest wall thickness for two false negatives diagnosed by Pneumoscan was 56.5 mm. However, no statistically significant difference was found between the chest wall thickness and the effectiveness of Pneumoscan on the detection of the PTX (p=0.77). Among sixty-seven false positives diagnosed by Pneumoscan, 46.3% had additional medical signs such as bronchiectasis, pulmonary consolidation, pulmonary edema or pulmonary tumor when they had a reading with CT. The relationship between having additional medical signs at the reading with CT and the effectiveness of Pneumoscan on the detection of the PTX was investigated and no significant difference was found (p=0.472). Using Pneumoscan to detect PTX is controversial since the device has a high false positive ratio. Wherein, false positive diagnosis can cause unjustifiable chest tube insertion. In addition, the device failed to show the size of the PTX, and therefore, it did not aid in determining the treatment and prognosis on contrary to traditional diagnostic methods. The findings could not demonstrate that the device was efficient in emergency care. Further studies and increasing experience may change this outcome in upcoming years.

  9. Is maternal serum triple screening a better predictor of Down syndrome in female than in male fetuses?

    PubMed

    Ghidini, A; Spong, C Y; Grier, R E; Walker, C N; Pezzullo, J C

    1998-02-01

    Among euploid gestations, female fetuses have been reported to have significantly lower maternal serum alpha-fetoprotein (MSAFP) and higher human chorionic gonadotropin (hCG) levels than male fetuses. Since in maternal serum triple screening, low MSAFP and high hCG MOM independently confer greater risk of a Down syndrome fetus, we investigated the hypothesis that maternal serum triple screening is more efficacious at detecting female than male Down syndrome fetuses. A database containing all karyotypes from amniocentesis performed between August 1994 and August 1996 was accessed. All trisomy 21 cases were identified. The male-to-female ratio among trisomy 21 fetuses detected at amniocentesis after abnormal maternal serum triple screening was compared with that among trisomy 21 fetuses detected at amniocentesis for advanced maternal age (AMA), which served as the control group. Statistical analysis utilized chi-square, Fisher's exact test, and Student's t-test. A P value of less than 0.05 was considered statistically significant. Forty-nine trisomy 21 fetuses were detected in the women who underwent amniocentesis because of abnormal triple screening and 311 were detected in the control group. The proportion of male fetuses among the triple screening group was not significantly different from that of the AMA group (55 per cent vs. 57 per cent; P=0.9). Our study had a power of 80 per cent to detect a difference of 25 per cent in the male-to-female ratio (alpha=0.05, beta=0.20). The reported differences in MSAFP and hCG levels between male and female euploid fetuses do not appear to affect the sex ratio among Down syndrome fetuses detected because of an abnormal maternal serum triple screening.

  10. Bias and discriminability during emotional signal detection in melancholic depression.

    PubMed

    Hyett, Matthew; Parker, Gordon; Breakspear, Michael

    2014-04-27

    Cognitive disturbances in depression are pernicious and so contribute strongly to the burden of the disorder. Cognitive function has been traditionally studied by challenging subjects with modality-specific psychometric tasks and analysing performance using standard analysis of variance. Whilst informative, such an approach may miss deeper perceptual and inferential mechanisms that potentially unify apparently divergent emotional and cognitive deficits. Here, we sought to elucidate basic psychophysical processes underlying the detection of emotionally salient signals across individuals with melancholic and non-melancholic depression. Sixty participants completed an Affective Go/No-Go (AGN) task across negative, positive and neutral target stimuli blocks. We employed hierarchical Bayesian signal detection theory (SDT) to model psychometric performance across three equal groups of those with melancholic depression, those with a non-melancholic depression and healthy controls. This approach estimated likely response profiles (bias) and perceptual sensitivity (discriminability). Differences in the means of these measures speak to differences in the emotional signal detection between individuals across the groups, while differences in the variance reflect the heterogeneity of the groups themselves. Melancholic participants showed significantly decreased sensitivity to positive emotional stimuli compared to those in the non-melancholic group, and also had a significantly lower discriminability than healthy controls during the detection of neutral signals. The melancholic group also showed significantly higher variability in bias to both positive and negative emotionally salient material. Disturbances of emotional signal detection in melancholic depression appear dependent on emotional context, being biased during the detection of positive stimuli, consistent with a noisier representation of neutral stimuli. The greater heterogeneity of the bias across the melancholic group is consistent with a more labile disorder (i.e. variable across the day). Future work will aim to understand how these findings reflect specific individual differences (e.g. prior cognitive biases) and clarify whether such biases change dynamically during cognitive tasks as internal models of the sensorium are refined and updated in response to experience.

  11. A method to determine the impact of reduced visual function on nodule detection performance.

    PubMed

    Thompson, J D; Lança, C; Lança, L; Hogg, P

    2017-02-01

    In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (-1.00 D and -2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1-4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to -1.00 D and for one observer when defocussed to -2.00 D. Stereoacuity was unacceptable for one observer when defocussed to -2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function. Copyright © 2016 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  12. The Influence of Assay Design, Blinding, and Gymnema sylvestre on Sucrose Detection by Humans.

    PubMed

    Aleman, Max G; Marconi, Lauren J; Nguyen, Nam H; Park, Jae M; Patino, Maria M; Wang, Yuchi; Watkins, Celeste S; Shelley, Chris

    2016-01-01

    The detection and grading of tastes corresponding to different taste modalities can be tested in engaging laboratory sessions using students themselves as test subjects. This article describes a series of experiments in which data pertaining to the detection of salty and sweet tastes are obtained, and the ability of the herb Gymnema sylvestre to disrupt the detection of sucrose is quantified. The effects of blinding and different assay designs on EC50 estimation are also investigated. The data obtained allow for substantial data analysis, including non-linear regression using fixed and free parameters to quantify dose-response relationships, and the use of often under-utilized permutation tests to determine significant differences when the underlying data display heteroscedasticity.

  13. The Influence of Assay Design, Blinding, and Gymnema sylvestre on Sucrose Detection by Humans

    PubMed Central

    Aleman, Max G.; Marconi, Lauren J.; Nguyen, Nam H.; Park, Jae M.; Patino, Maria M.; Wang, Yuchi; Watkins, Celeste S.; Shelley, Chris

    2016-01-01

    The detection and grading of tastes corresponding to different taste modalities can be tested in engaging laboratory sessions using students themselves as test subjects. This article describes a series of experiments in which data pertaining to the detection of salty and sweet tastes are obtained, and the ability of the herb Gymnema sylvestre to disrupt the detection of sucrose is quantified. The effects of blinding and different assay designs on EC50 estimation are also investigated. The data obtained allow for substantial data analysis, including non-linear regression using fixed and free parameters to quantify dose-response relationships, and the use of often under-utilized permutation tests to determine significant differences when the underlying data display heteroscedasticity. PMID:27980466

  14. Effect of sample storage time on detection of hybridization signals in Checkerboard DNA-DNA hybridization.

    PubMed

    do Nascimento, Cássio; Muller, Katia; Sato, Sandra; Albuquerque Junior, Rubens Ferreira

    2012-04-01

    Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 °C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p < 0.001). No differences were found between groups 1 and 2 (p > 0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.

  15. A Multi-Scale Algorithm for Graffito Advertisement Detection from Images of Real Estate

    NASA Astrophysics Data System (ADS)

    Yang, Jun; Zhu, Shi-Jiao

    There is a significant need to detect and extract the graffito advertisement embedded in the housing images automatically. However, it is a hard job to separate the advertisement region well since housing images generally have complex background. In this paper, a detecting algorithm which uses multi-scale Gabor filters to identify graffito regions is proposed. Firstly, multi-scale Gabor filters with different directions are applied to housing images, then the approach uses these frequency data to find likely graffito regions using the relationship of different channels, it exploits the ability of different filters technique to solve the detection problem with low computational efforts. Lastly, the method is tested on several real estate images which are embedded graffito advertisement to verify its robustness and efficiency. The experiments demonstrate graffito regions can be detected quite well.

  16. Point Count Length and Detection of Forest Neotropical Migrant Birds

    Treesearch

    Deanna K. Dawson; David R. Smith; Chandler S. Robbins

    1995-01-01

    Comparisons of bird abundances among years or among habitats assume that the rates at which birds are detected and counted are constant within species. We use point count data collected in forests of the Mid-Atlantic states to estimate detection probabilities for Neotropical migrant bird species as a function of count length. For some species, significant differences...

  17. The difference of detecting water mist and smoke by electromagnetic wave in simulation experiments

    NASA Astrophysics Data System (ADS)

    Zhang, Jingdi; Cui, Bing; Xiao, Si

    2015-10-01

    Although mist is similar to smoke in morphology, their compositions are very different. Therefore there is a significant difference between mist and smoke when detected by electromagnetic wave. This paper puts forward a kind of feasible solution based on Ansoft HFSS software about how to determine the forest fire by distinguishing mist and smoke above the forest. The experiments simulate the difference between mist and smoke model when detected by electromagnetic wave in different wavelengths. We find the mist and smoke model cannot absorb or reflect electromagnetic wave efficiently in Megahertz band. While in Gigahertz band mist model began to absorb and reflect electromagnetic wave above 650 Gigahertz band, but no change in smoke model. And the biggest difference appears in Terahertz band.

  18. The Combination of Atracurium and Vecuronium Compared to Vecuronium Administered Alone: Evaluation of the Time of Onset, Duration of Action, Intubating Conditions, and Cardiovascular Effects

    DTIC Science & Technology

    1990-06-01

    10 minutes after injection. No significant differences detected between the groups. 18 0 Table 7. Systolic Blood Pressure Group Atracurium 0.40 mg/kg...Table 8. Diastolic Blood Pressure Group Atracurium 0.40 mg/kg + Vecuronium 0.28 mg/kg Vecuronium 0.10 mg/kg (n=20) (n=20) Baseline(a) 72 + 2.4 72...significant differences detected between the groups. 20 0 Table 9. Mean Blood Pressure Group Atracurium 0.40 mg/kg + Vecuronium 0.28 mg/kg Vecuronium 0.10

  19. Reliability of a portable device for the detection of sleep bruxism.

    PubMed

    Deregibus, Andrea; Castroflorio, Tommaso; Bargellini, Andrea; Debernardi, Cesare

    2014-11-01

    The aim of the study was to assess the repeatability in detecting sleep bruxism (SB) episodes by combined surface electromyography and heart rate (HR) signals recorded by a compact portable device (Bruxoff®). SB episodes are preceded by a sudden HR change. Thus, HR detection increases the precision of automatic detection of SB. Ten healthy subjects (five women and five men; 30.2 ± 11.02 years) were selected for the study. Rhythmic masseter muscle activities, constituting the basic pattern of SB, were detected during three nights of recording during three different weeks with the Bruxoff device. The two-way ANOVA was not significant for SB episodes per night, SB episodes per hour, and heart frequency: no significant differences were observed during the three different nights of recording for each of the abovementioned variables (P > 0.05). The intraclass correlation coefficient showed a good reproducibility for SB episodes per night (69 %), SB per hour (74 %), and heart frequency (82 %). A poor reproducibility was revealed for the number of masseter contractions (53 %). The Pearson analysis showed the absence of a significant correlation between the number of masseter contractions per night and the number of SB episodes per night (r = -0.02, P = 0.91). The Bruxoff device showed a good reproducibility of measurements of sleep bruxism episodes over time. These findings are important in the light of the need for simple and reliable portable devices for the diagnosis of SB both in the clinical and research settings.

  20. Differences in compassion fatigue, symptoms of posttraumatic stress disorder and relationship satisfaction, including sexual desire and functioning, between male and female detectives who investigate sexual offenses against children: a pilot study.

    PubMed

    Lane, Eric J; Lating, Jeffrey M; Lowry, Jenny L; Martino, Traci P

    2010-01-01

    Law enforcement detectives who work with traumatized individuals, especially children who were victims of sexual abuse or assault, are likely to experience job-related emotional distress. The purpose of this study was to examine the relations among compassion fatigue, probable PTSD symptoms, and personal relationship satisfaction, including communication and sexual satisfaction, in a sample of 47 male and female detectives. Responses to the administered questionnaires indicated a relation between compassion fatigue symptoms and probable PTSD symptoms. There also were compelling gender differences. For example, for male detectives, open communication with their spouse or significant other was negatively correlated with burnout, indicating the more open the communication, the lower the reported burnout. However for female detectives there was a negative correlation between open communication with spouse or significant other and compassion satisfaction, suggesting that more open communication was related to lower levels of satisfaction with their ability to be a professional caregiver Furthermore, although stepwise regression analysis indicated that years of service as a detective is independently associated with sexual desire, female detectives evidenced less sexual desire and more difficulty with sexual functioning than did male detectives. Implications of these preliminary findings are discussed and limitations addressed.

  1. Decision-making by experienced rugby referees: use of perceptual information and episodic memory.

    PubMed

    MacMahon, Clare; Ste-Marie, Diane M

    2002-10-01

    The expertise paradigm was used in two studies to examine decision-making by rugby referees. Videoclips were used to assess infraction detection and knowledge base, or sources of information used. In Study 1, referees of high and low experience were compared, and in Study 2 referees and players were compared. Analysis by signal detection used a framework to classify types of information. Study 1 yielded no differences in detection of infractions as a function of experience, however, referees of high experience used significantly more sources of information than the group with low experience across all categories of information. In Study 2, there were no significant differences between referees and players, with the exception that referees displayed greater use of episodic memory information in decision-making.

  2. Data-Mining and Informatics Approaches for Environmental Contaminants

    EPA Science Inventory

    New and emerging environmental contaminants are chemicals that have not been previously detected or that are being detected at levels significantly different from those expected in both biological and ecological arenas (that is, human, wildlife, and environment). Many chemicals c...

  3. [Detection rate analysis on neurological sign of workers exposed to different concentrations of carbon disulfide].

    PubMed

    Li, Kuirong; Zhou, Wenhui; Gu, Guizhen; Zhou, Shiyi; Zheng, Yuxin; Yu, Shanfa

    2014-10-01

    To study the effects of exposed to different concentrations of carbon disulfide on neurological signs of workers. Collection the information of concentration of carbon disulfide in the workplace or workers individuals exposed of a chemical fiber industry from 2004 to 2011, a total of 3 537 workers exposed to carbon disulfide were detected muscle strength and muscle tone, knee reflex, Achilles tendon reflex, trembling limbs, sensory function, and three chatter. Chi-square test was used for statistical analysis on abnormal neurological signs of workers. Eight hours time-weighted average concentration range of workers exposed to carbon disulfide in this chemical fiber industry was 0.2-41.0 mg/m(3), geometric mean was 2.38 mg/m(3). Concentration of carbon disulfide exposure of 1 771 workers was from 0.2 to 2.5 mg/m3( ≤ 2.5 mg/m(3)), 642 workers was 2.6-4.8 mg/m(3) (< 5.0 mg/m(3)), other 1 051 workers was from 5.1 to 41.0 mg/m(3) ( > 5.0 mg/m(3)) in all subjects. The different detection rates of knee reflex were 3.0% (31/1 045), 3.7% (21/574), 4.8% (16/331), 3.3% (10/305), 5.9% (11/187), 6.7% (68/1 022), the different detection rates of Achilles tendon reflex were 2.2% (23/1 045), 3.7% (21/574), 2.7% (9/331), 2.3% (7/305), 2.1% (4/187), 5.6% (57/1 022), the different detection rates of sensory dysfunction were 0.4% (4/1 045), 0.5% (3/574), 0.6% (2/331), 0.0% (0/305), 2.1% (4/187), 1.7% (17/1 022) in different cumulative amount of contact groups ( ≤ 10.0, 10.1-20.0, 20.1-30.0, 30.1-40.0, 40.1-50.0, >50.0 mg/m(3) per year), and the differences were statistically significant (χ(2) = 19.53, 21.27 and 15.89, all P values were <0.01) . Stratified according to age and gender, in addition to the ≤ 25 years group the difference of detection rate analysis on Achilles tendon reflex was statistically significant in the different concentration group (the ratio of on Achilles tendon reflex in the different groups of concentration of carbon disulfide exposure of 2.5, 2.6-5.0, ≥ 5.0 mg/m(3) were 0.4% (2/511), 1.0% (1/98), 2.1% (7/327), χ(2) = 5.59, P = 0.045) , the difference of detection rate analysis on neurological sign was not statistically significant in the different concentration group on the rest of the age and gender groups (P > 0.05). Within the concentration range of the object of study contact actual, different concentrations of carbon disulfide in addition to individual neurological signs of individual ages influential, it has no significant effect on the various signs of nervous system of workers of most age and gender groups, expect the age below the 25 years old group.

  4. Impact of compressed breast thickness and dose on lesion detectability in digital mammography: FROC study with simulated lesions in real mammograms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salvagnini, Elena, E-mail: elena.salvagnini@gmail.

    Purpose: The aim of this work was twofold: (1) to examine whether, with standard automatic exposure control (AEC) settings that maintain pixel values in the detector constant, lesion detectability in clinical images decreases as a function of breast thickness and (2) to verify whether a new AEC setup can increase lesion detectability at larger breast thicknesses. Methods: Screening patient images, acquired on two identical digital mammography systems, were collected over a period of 2 yr. Mammograms were acquired under standard AEC conditions (part 1) and subsequently with a new AEC setup (part 2), programmed to use the standard AEC settingsmore » for compressed breast thicknesses ≤49 mm, while a relative dose increase was applied above this thickness. The images were divided into four thickness groups: T1 ≤ 29 mm, T2 = 30–49 mm, T3 = 50–69 mm, and T4 ≥ 70 mm, with each thickness group containing 130 randomly selected craniocaudal lesion-free images. Two measures of density were obtained for every image: a BI-RADS score and a map of volumetric breast density created with a software application (VolparaDensity, Matakina, NZ). This information was used to select subsets of four images, containing one image from each thickness group, matched to a (global) BI-RADS score and containing a region with the same (local) VOLPARA volumetric density value. One selected lesion (a microcalcification cluster or a mass) was simulated into each of the four images. This process was repeated so that, for a given thickness group, half the images contained a single lesion and half were lesion-free. The lesion templates created and inserted in groups T3 and T4 for the first part of the study were then inserted into the images of thickness groups T3 and T4 acquired with higher dose settings. Finally, all images were visualized using the ViewDEX software and scored by four radiologists performing a free search study. A statistical jackknife-alternative free-response receiver operating characteristic analysis was applied. Results: For part 1, the alternative free-response receiver operating characteristic curves for the four readers were 0.80, 0.65, 0.55 and 0.56 in going from T1 to T4, indicating a decrease in detectability with increasing breast thickness. P-values and the 95% confidence interval showed no significant difference for the T3-T4 comparison (p = 0.78) while all the other differences were significant (p < 0.05). Separate analysis of microcalcification clusters presented the same results while for mass detection, the only significant difference came when comparing T1 to the other thickness groups. Comparing the scores of part 1 and part 2, results for the T3 group acquired with the new AEC setup and T3 group at standard AEC doses were significantly different (p = 0.0004), indicating improved detection. For this group a subanalysis for microcalcification detection gave the same results while no significant difference was found for mass detection. Conclusions: These data using clinical images confirm results found in simple QA tests for many mammography systems that detectability falls as breast thickness increases. Results obtained with the AEC setup for constant detectability above 49 mm showed an increase in lesion detection with compressed breast thickness, bringing detectability of lesions to the same level.« less

  5. Effect of image quality on calcification detection in digital mammography

    PubMed Central

    Warren, Lucy M.; Mackenzie, Alistair; Cooke, Julie; Given-Wilson, Rosalind M.; Wallis, Matthew G.; Chakraborty, Dev P.; Dance, David R.; Bosmans, Hilde; Young, Kenneth C.

    2012-01-01

    Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Conclusions: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection. PMID:22755704

  6. Effect of image quality on calcification detection in digital mammography.

    PubMed

    Warren, Lucy M; Mackenzie, Alistair; Cooke, Julie; Given-Wilson, Rosalind M; Wallis, Matthew G; Chakraborty, Dev P; Dance, David R; Bosmans, Hilde; Young, Kenneth C

    2012-06-01

    This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection. © 2012 American Association of Physicists in Medicine.

  7. Comparative analysis on microbial community associated with different gastrointestinal regions of wild northern snakehead Channa argus Cantor, 1842

    NASA Astrophysics Data System (ADS)

    Miao, Shuyan; Zhao, Chenze; Zhu, Jinyu; Pan, Mingzhu

    2018-03-01

    Microbial communities in different gastrointestinal regions (stomach, foregut, midgut, and hindgut) of the northern snakehead Channa argus (Cantor, 1842) were compared by polymerase chain reaction and partial 16S rDNA sequencing. A total of 194, 140, 212, and 122 OTUs were detected in the stomach, foregut, midgut, and hindgut, respectively. Significant differences were found in the Sobs, ACE, Shannon, and Simpson indices among samples ( P<0.05). The gastrointestinal microbial community of C. argus consisted predominantly of Proteobacteria with either Halomonas, Shewanella, Plesiomonas, or Sphingomonas. Fusobacteria, Firmicutes, and Bacteroidetes also existed in the gastrointestinal tracts. However, significant differences were found in the compositions of microbial community among the four regions ( P<0.05). Cyanobacteria and Spirochetes were significantly higher in the midgut and hindgut ( P<0.05). Fusobacteria and Firmicutes were dominant in the hindgut and foregut, respectively ( P<0.05). Proteobacteria was the lowest in the hindgut ( P<0.05). At genus level, Cetobacterium and Plesiomonas were significantly higher in the hindgut than in the other three samples ( P<0.05). Clostridium and Prevotella were the highest in the midgut ( P<0.05). Halomonas, Shewanella, and Sphingomonas were the highest in the foregut ( P<0.05). Paracoccus and Vibrio were the highest in the stomach. Several genera were only detected in certain regions, as follows: stomach, Paracoccus and Vibrio; foregut, Halomonas, Shewanella, and Sphingomonas; midgut, Clostridium and Prevotella; and hindgut, Cetobacterium and Plesiomonas ( P<0.05). At the species level, Acinetobacter rhizosphaerae was only detected in the stomach. Prevotella copri and Clostridium perfring were not detected in the foregut and midgut, respectively, whereas Prevotella copri and Faecalibacterium pra were not detected in the hindgut. These findings provide valuable information on the microbial community in each gastrointestinal region of C. argus. Moreover, this study indicated that microbial community was not only related to rearing environment but also to the physico-chemical characteristics of each gastrointestinal region.

  8. Efficacy of reciprocating and rotary NiTi instruments for retreatment of curved root canals assessed by micro-CT.

    PubMed

    Rödig, T; Reicherts, P; Konietschke, F; Dullin, C; Hahn, W; Hülsmann, M

    2014-10-01

    To compare the efficacy of reciprocating and rotary NiTi-instruments in removing filling material from curved root canals using micro-computed tomography. Sixty curved root canals were prepared and filled with gutta-percha and sealer. After determination of root canal curvatures and radii in two directions as well as volumes of filling material, the teeth were assigned to three comparable groups (n = 20). Retreatment was performed using Reciproc, ProTaper Universal Retreatment or Hedström files. Percentages of residual filling material and dentine removal were assessed using micro-CT imaging. Working time and procedural errors were recorded. Statistical analysis was performed by variance procedures. No significant differences amongst the three retreatment techniques concerning residual filling material were detected (P > 0.05). Hedström files removed significantly more dentine than ProTaper Universal Retreatment (P < 0.05), but the difference concerning dentine removal between both NiTi systems was not significant (P > 0.05). Reciproc and ProTaper Universal Retreatment were significantly faster than Hedström files (P = 0.0001). No procedural errors such as instrument fracture, blockage, ledging or perforation were detected for Hedström files. Three perforations were recorded for ProTaper Universal Retreatment, and in both NiTi groups, one instrument fracture occured. Remnants of filling material were observed in all samples with no significant differences between the three techniques. Hedström files removed significantly more dentine than ProTaper Universal Retreatment, but no significant differences between both NiTi systems were detected. Procedural errors were observed with ProTaper Universal Retreatment and Reciproc. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. Steatosis Grade is the Most Important Risk Factor for Development of Endothelial Dysfunction in NAFLD

    PubMed Central

    Sapmaz, Ferdane; Uzman, Metin; Basyigit, Sebahat; Ozkan, Selcuk; Yavuz, Bunyamin; Yeniova, Abdullah; Kefeli, Ayse; Asilturk, Zeliha; Nazligül, Yasar

    2016-01-01

    Abstract It is shown that there are strong associations between nonalcoholic fatty liver disease (NAFLD) and endothelial dysfunction. The aim of our study was to reveal whether steatosis or fibrosis score is more important in the development of endothelial dysfunction in patients with NAFLD in a prospective manner. This cross-sectional study included 266 subjects. These subjects were divided into 2 groups depending on presence of hepatosteatosis sonographically. Patients with hepatosteatosis were also divided into 3 subgroups depending on degree of steatosis: grade 1, 2, and 3. In all patients, Aspartate aminotransferase-to-Platelet Ratio Index and Fibrosis-4 (FIB4) scores were calculated. In addition, flow-mediated dilatation (FMD) measurements were recorded. There was NAFLD in 176 (66.2%) of 266 patients included. There were no significant differences in sex and age distributions between patients with NAFLD (group 1) and controls without NAFLD (group 2) (P = 0.05). Mean Aspartate aminotransferase-to-Platelet Ratio Index score was significantly higher in group 1 compared with the control group (P = 0.001), whereas no significant difference was detected regarding FIB4 scores between groups (P = 0.4). Mean FMD value was found to be significantly lower in group 1 (P = 0.008). Patients with grade 3 hepatosteatosis had significantly lower FMD values than those with grade 1 steatosis and controls (P = 0.001). In univariate and multivariate analyses in group 1, no significant difference was detected regarding mean FMD measurements (P = 0.03). Again, no significant difference was detected in mean FMD measurement between FIB4 subgroups among patients with NAFLD and the whole study group (P = 0.09). The endothelial dysfunction is associated with steatosis in patients with NAFLD. PMID:27057890

  10. Impact of mammographic screening on ethnic and socioeconomic inequities in breast cancer stage at diagnosis and survival in New Zealand: a cohort study.

    PubMed

    Seneviratne, Sanjeewa; Campbell, Ian; Scott, Nina; Shirley, Rachel; Lawrenson, Ross

    2015-01-31

    Indigenous Māori women experience a 60% higher breast cancer mortality rate compared with European women in New Zealand. We explored the impact of differences in rates of screen detected breast cancer on inequities in cancer stage at diagnosis and survival between Māori and NZ European women. All primary breast cancers diagnosed in screening age women (as defined by the New Zealand National Breast Cancer Screening Programme) during 1999-2012 in the Waikato area (n = 1846) were identified from the Waikato Breast Cancer Register and the National Screening Database. Stage at diagnosis and survival were compared for screen detected (n = 1106) and non-screen detected (n = 740) breast cancer by ethnicity and socioeconomic status. Indigenous Māori women were significantly more likely to be diagnosed with more advanced cancer compared with NZ European women (OR = 1.51), and approximately a half of this difference was explained by lower rate of screen detected cancer for Māori women. For non-screen detected cancer, Māori had significantly lower 10-year breast cancer survival compared with NZ European (46.5% vs. 73.2%) as did most deprived compared with most affluent socioeconomic quintiles (64.8% vs. 81.1%). No significant survival differences were observed for screen detected cancer by ethnicity or socioeconomic deprivation. The lower rate of screen detected breast cancer appears to be a key contributor towards the higher rate of advanced cancer at diagnosis and lower breast cancer survival for Māori compared with NZ European women. Among women with screen-detected breast cancer, Māori women do just as well as NZ European women, demonstrating the success of breast screening for Māori women who are able to access screening. Increasing breast cancer screening rates has the potential to improve survival for Māori women and reduce breast cancer survival inequity between Māori and NZ European women.

  11. Using lod scores to detect sex differences in male-female recombination fractions.

    PubMed

    Feenstra, B; Greenberg, D A; Hodge, S E

    2004-01-01

    Human recombination fraction (RF) can differ between males and females, but investigators do not always know which disease genes are located in genomic areas of large RF sex differences. Knowledge of RF sex differences contributes to our understanding of basic biology and can increase the power of a linkage study, improve gene localization, and provide clues to possible imprinting. One way to detect these differences is to use lod scores. In this study we focused on detecting RF sex differences and answered the following questions, in both phase-known and phase-unknown matings: (1) How large a sample size is needed to detect a RF sex difference? (2) What are "optimal" proportions of paternally vs. maternally informative matings? (3) Does ascertaining nonoptimal proportions of paternally or maternally informative matings lead to ascertainment bias? Our results were as follows: (1) We calculated expected lod scores (ELODs) under two different conditions: "unconstrained," allowing sex-specific RF parameters (theta(female), theta(male)); and "constrained," requiring theta(female) = theta(male). We then examined the DeltaELOD (identical with difference between maximized constrained and unconstrained ELODs) and calculated minimum sample sizes required to achieve statistically significant DeltaELODs. For large RF sex differences, samples as small as 10 to 20 fully informative matings can achieve statistical significance. We give general sample size guidelines for detecting RF differences in informative phase-known and phase-unknown matings. (2) We defined p as the proportion of paternally informative matings in the dataset; and the optimal proportion p(circ) as that value of p that maximizes DeltaELOD. We determined that, surprisingly, p(circ) does not necessarily equal (1/2), although it does fall between approximately 0.4 and 0.6 in most situations. (3) We showed that if p in a sample deviates from its optimal value, no bias is introduced (asymptotically) to the maximum likelihood estimates of theta(female) and theta(male), even though ELOD is reduced (see point 2). This fact is important because often investigators cannot control the proportions of paternally and maternally informative families. In conclusion, it is possible to reliably detect sex differences in recombination fraction. Copyright 2004 S. Karger AG, Basel

  12. Reliability of Pseudotyped Influenza Viral Particles in Neutralizing Antibody Detection

    PubMed Central

    Yang, Jinghui; Li, Weidong; Long, Yunfeng; Song, Shaohui; Liu, Jing; Zhang, Xinwen; Wang, Xiaoguang; Jiang, Shude; Liao, Guoyang

    2014-01-01

    Background Current influenza control strategies require an active surveillance system. Pseudotyped viral particles (pp) together with the evaluation of pre-existing immunity in a population might satisfy this requirement. However, the reliability of using pp in neutralizing antibody (nAb) detection are undefined. Methodology/Principal Findings Pseudotyped particles of A(H1N1)pmd09 (A/California/7/2009) and HPAI H5N1 (A/Anhui/1/2005), as well as their reassortants, were generated. The reliability of using these pp in nAb detection were compared concurrently with the corresponding viruses by a hemagglutination inhibition test, as well as ELISA-, cytopathic effect-, and fluorescence-based microneutralization assays. In the qualitative detection on nAbs, the pp and their corresponding viruses were in complete agreement, with an R2 value equal to or near 1 in two different populations. In the quantitative detection on nAbs, although the geometric mean titers (95% confidence interval) differed between the pp and viruses, no significant difference was observed. Furthermore, humoral immunity against the reassortants was evaluated; our results indicated strong consistency between the nAbs against reassortant pp and those against naïve pp harboring the same hemagglutinin. Conclusion/Significance The pp displayed high reliability in influenza virus nAb detection. The use of reassortant pp is a safe and convenient strategy for characterizing emerging influenza viruses and surveying the disease burden. PMID:25436460

  13. Intraspecific Variation of Centruroides Edwardsii Venom from Two Regions of Colombia

    PubMed Central

    Estrada-Gómez, Sebastián; Cupitra, Nelson Ivan; Arango, Walter Murillo; Vargas Muñoz, Leidy Johana

    2014-01-01

    We report the first description studies, partial characterization, and intraspecific difference of Centruroides edwardsii, Gervais 1843, venom. C. edwardsii from two Colombian regions (Antioquia and Tolima) were evaluated. Both venoms showed hemolytic activity, possibly dependent of enzymatic active phospholipases, and neither coagulant nor proteolytic activities were observed. Venom electrophoretic profile showed significant differences between C. edwardsii venom from both regions. A high concentration of proteins with molecular masses between 31 kDa and 97.4 kDa, and an important concentration close or below 14.4 kDa were detected. RP-HPLC retention times between 38.2 min and 42.1 min, showed bands close to 14.4 kDa, which may correspond to phospholipases. RP-HPLC venom profile showed a well conserved region in both venoms between 7 and 17 min, after this, significant differences were detected. From Tolima region venom, 50 well-defined peaks were detected, while in the Antioquia region venom, 55 well-defined peaks were detected. Larvicidal activity was only detected in the C. edwardsii venom from Antioquia. No antimicrobial activity was observed using complete venom or RP-HPLC collected fractions of both venoms. Lethally activity (carried out on female albino swiss mice) was detected at doses over 19.2 mg/kg of crude venom. Toxic effects included distress, excitability, eye irritation and secretions, hyperventilation, ataxia, paralysis, and salivation. PMID:25025710

  14. The clinical performance evaluation of novel protein chips for eleven biomarkers detection and the diagnostic model study.

    PubMed

    Luo, Yuan; Zhu, Xu; Zhang, Pengjun; Shen, Qian; Wang, Zi; Wen, Xinyu; Wang, Ling; Gao, Jing; Dong, Jin; Yang, Caie; Wu, Tangming; Zhu, Zheng; Tian, Yaping

    2015-01-01

    We aimed to develop and validate two novel protein chips, which are based on microarray chemiluminescence immunoassay and can simultaneously detected 11 biomarkers, and then to evaluate their clinical diagnostic value by comparing with the traditional methods. Protein chips were evaluated for limit of detection, specificity, common interferences, linearity, precision and accuracy. 11 biomarkers were simultaneously detected by traditional methods and protein chips in 3683 samples, which included 1723 cancer patients, 1798 benign diseases patients and 162 healthy controls. After assay validation, protein chips demonstrated high sensitivity, high specificity, good linearity, low imprecision and were free of common interferences. Compared with the traditional methods, protein chips have good correlation in the detection of all the 13 kinds of biomarkers (r≥0.935, P<0.001). For specific cancer detection, there were no statistically significant differences between the traditional method and novel protein chips, except that male protein chip showed significantly better diagnostic value on NSE detection (P=0.004) but significantly worse value on pro-GRP detection (P=0.012), female chip showed significantly better diagnostic value on pro-GRP detection (P=0.005). Furthermore, both male and female multivariate diagnostic models had significantly better diagnostic value than single detection of PGI, PG II, pro-GRP, NSE and CA125 (P<0.05). In addition, male models had significantly better diagnostic value than single CA199 and free-PSA (P<0.05), while female models observed significantly better diagnostic value than single CA724 and β-HCG (P<0.05). For total disease or cancer detection, the AUC of multivariate logistic regression for the male and female disease detection was 0.981 (95% CI: 0.975-0.987) and 0.836 (95% CI: 0.798-0.874), respectively. While, that for total cancer detection was 0.691 (95% CI: 0.666-0.717) and 0.753 (95% CI: 0.731-0.775), respectively. The new designed protein chips are simple, multiplex and reliable clinical assays and the multi-parameter diagnostic models based on them could significantly improve their clinical performance.

  15. The clinical performance evaluation of novel protein chips for eleven biomarkers detection and the diagnostic model study

    PubMed Central

    Luo, Yuan; Zhu, Xu; Zhang, Pengjun; Shen, Qian; Wang, Zi; Wen, Xinyu; Wang, Ling; Gao, Jing; Dong, Jin; Yang, Caie; Wu, Tangming; Zhu, Zheng; Tian, Yaping

    2015-01-01

    We aimed to develop and validate two novel protein chips, which are based on microarray chemiluminescence immunoassay and can simultaneously detected 11 biomarkers, and then to evaluate their clinical diagnostic value by comparing with the traditional methods. Protein chips were evaluated for limit of detection, specificity, common interferences, linearity, precision and accuracy. 11 biomarkers were simultaneously detected by traditional methods and protein chips in 3683 samples, which included 1723 cancer patients, 1798 benign diseases patients and 162 healthy controls. After assay validation, protein chips demonstrated high sensitivity, high specificity, good linearity, low imprecision and were free of common interferences. Compared with the traditional methods, protein chips have good correlation in the detection of all the 13 kinds of biomarkers (r≥0.935, P<0.001). For specific cancer detection, there were no statistically significant differences between the traditional method and novel protein chips, except that male protein chip showed significantly better diagnostic value on NSE detection (P=0.004) but significantly worse value on pro-GRP detection (P=0.012), female chip showed significantly better diagnostic value on pro-GRP detection (P=0.005). Furthermore, both male and female multivariate diagnostic models had significantly better diagnostic value than single detection of PGI, PG II, pro-GRP, NSE and CA125 (P<0.05). In addition, male models had significantly better diagnostic value than single CA199 and free-PSA (P<0.05), while female models observed significantly better diagnostic value than single CA724 and β-HCG (P<0.05). For total disease or cancer detection, the AUC of multivariate logistic regression for the male and female disease detection was 0.981 (95% CI: 0.975-0.987) and 0.836 (95% CI: 0.798-0.874), respectively. While, that for total cancer detection was 0.691 (95% CI: 0.666-0.717) and 0.753 (95% CI: 0.731-0.775), respectively. The new designed protein chips are simple, multiplex and reliable clinical assays and the multi-parameter diagnostic models based on them could significantly improve their clinical performance. PMID:26884957

  16. Dispersal of potato cyst nematodes measured using historical and spatial statistical analyses.

    PubMed

    Banks, N C; Hodda, M; Singh, S K; Matveeva, E M

    2012-06-01

    Rates and modes of dispersal of potato cyst nematodes (PCNs) were investigated. Analysis of records from eight countries suggested that PCNs spread a mean distance of 5.3 km/year radially from the site of first detection, and spread 212 km over ≈40 years before detection. Data from four countries with more detailed histories of invasion were analyzed further, using distance from first detection, distance from previous detection, distance from nearest detection, straight line distance, and road distance. Linear distance from first detection was significantly related to the time since the first detection. Estimated rate of spread was 5.7 km/year, and did not differ statistically between countries. Time between the first detection and estimated introduction date varied between 0 and 20 years, and differed among countries. Road distances from nearest and first detection were statistically significantly related to time, and gave slightly higher estimates for rate of spread of 6.0 and 7.9 km/year, respectively. These results indicate that the original site of introduction of PCNs may act as a source for subsequent spread and that this may occur at a relatively constant rate over time regardless of whether this distance is measured by road or by a straight line. The implications of this constant radial rate of dispersal for biosecurity and pest management are discussed, along with the effects of control strategies.

  17. Automatic QRS complex detection using two-level convolutional neural network.

    PubMed

    Xiang, Yande; Lin, Zhitao; Meng, Jianyi

    2018-01-29

    The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especially in the transform domains. In addition, fixed features and parameters are not suitable for detecting various kinds of QRS complexes under different circumstances. In this study, based on 1-D convolutional neural network (CNN), an accurate method for QRS complex detection is proposed. The CNN consists of object-level and part-level CNNs for extracting different grained ECG morphological features automatically. All the extracted morphological features are used by multi-layer perceptron (MLP) for QRS complex detection. Additionally, a simple ECG signal preprocessing technique which only contains difference operation in temporal domain is adopted. Based on the MIT-BIH arrhythmia (MIT-BIH-AR) database, the proposed detection method achieves overall sensitivity Sen = 99.77%, positive predictivity rate PPR = 99.91%, and detection error rate DER = 0.32%. In addition, the performance variation is performed according to different signal-to-noise ratio (SNR) values. An automatic QRS detection method using two-level 1-D CNN and simple signal preprocessing technique is proposed for QRS complex detection. Compared with the state-of-the-art QRS complex detection approaches, experimental results show that the proposed method acquires comparable accuracy.

  18. Elastic Versus Rigid Image Registration in Magnetic Resonance Imaging-transrectal Ultrasound Fusion Prostate Biopsy: A Systematic Review and Meta-analysis.

    PubMed

    Venderink, Wulphert; de Rooij, Maarten; Sedelaar, J P Michiel; Huisman, Henkjan J; Fütterer, Jurgen J

    2016-07-29

    The main difference between the available magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) fusion platforms for prostate biopsy is the method of image registration being either rigid or elastic. As elastic registration compensates for possible deformation caused by the introduction of an ultrasound probe for example, it is expected that it would perform better than rigid registration. The aim of this meta-analysis is to compare rigid with elastic registration by calculating the detection odds ratio (OR) for both subgroups. The detection OR is defined as the ratio of the odds of detecting clinically significant prostate cancer (csPCa) by MRI-TRUS fusion biopsy compared with systematic TRUS biopsy. Secondary objectives were the OR for any PCa and the OR after pooling both registration techniques. The electronic databases PubMed, Embase, and Cochrane were systematically searched for relevant studies according to the Preferred Reporting Items for Systematic Review and Meta-analysis Statement. Studies comparing MRI-TRUS fusion and systematic TRUS-guided biopsies in the same patient were included. The quality assessment of included studies was performed using the Quality Assessment of Diagnostic Accuracy Studies version 2. Eleven papers describing elastic and 10 describing rigid registration were included. Meta-analysis showed an OR of csPCa for elastic and rigid registration of 1.45 (95% confidence interval [CI]: 1.21-1.73, p<0.0001) and 1.40 (95% CI: 1.13-1.75, p=0.002), respectively. No significant difference was seen between the subgroups (p=0.83). Pooling subgroups resulted in an OR of 1.43 (95% CI: 1.25-1.63, p<0.00001). No significant difference was identified between rigid and elastic registration for MRI-TRUS fusion-guided biopsy in the detection of csPCa; however, both techniques detected more csPCa than TRUS-guided biopsy alone. We did not identify any significant differences in prostate cancer detection between two distinct magnetic resonance imaging-transrectal ultrasound fusion systems which vary in their method of compensating for prostate deformation. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  19. Detection of Mycobacterium bovis in Bovine and Bubaline Tissues Using Nested-PCR for TbD1

    PubMed Central

    Araújo, Cristina P.; Osório, Ana Luiza A. R.; Jorge, Kláudia S. G.; Ramos, Carlos Alberto N.; Filho, Antonio Francisco S.; Vidal, Carlos Eugênio S.; Roxo, Eliana; Nishibe, Christiane; Almeida, Nalvo F.; Júnior, Antônio A. F.; Silva, Marcio R.; Neto, José Diomedes B.; Cerqueira, Valíria D.; Zumárraga, Martín J.; Araújo, Flábio R.

    2014-01-01

    In the present study, a nested-PCR system, targeting the TbD1 region, involving the performance of conventional PCR followed by real-time PCR, was developed to detect Mycobacterium bovis in bovine/bubaline tissue homogenates. The sensitivity and specificity of the reactions were assessed with DNA samples extracted from tuberculous and non-tuberculous mycobacteria, as well as other actinomycetales species and DNA samples extracted directly from bovine and bubaline tissue homogenates. In terms of analytical sensitivity, the DNA of M. bovis AN5 was detected up to 1.56 ng with conventional PCR, 97.6 pg with real-time PCR, and 1.53 pg with nested-PCR in the reaction mixture. The nested-PCR exhibited 100% analytical specificity for M. bovis when tested with the DNA of reference strains of environmental mycobacteria and closely-related Actinomycetales. A clinical sensitivity value of 76.0% was detected with tissue samples from animals that exhibited positive results in the comparative intradermal tuberculin test (CITT), as well as from those with lesions compatible with tuberculosis (LCT) that rendered positive cultures. A clinical specificity value of 100% was detected with tissue samples from animals with CITT- results, with no visible lesions (NVL) and negative cultures. No significant differences were found between the nested-PCR and culture in terms of detecting CITT+ animals with LCT or with NVL. No significant differences were recorded in the detection of CITT- animals with NVL. However, nested-PCR detected a significantly higher number of positive animals than the culture in the group of animals exhibiting LCT with no previous records of CITT. The use of the nested-PCR assay to detect M. bovis in tissue homogenates provided a rapid diagnosis of bovine and bubaline tuberculosis. PMID:24618787

  20. Detection of Mycobacterium bovis in bovine and bubaline tissues using nested-PCR for TbD1.

    PubMed

    Araújo, Cristina P; Osório, Ana Luiza A R; Jorge, Kláudia S G; Ramos, Carlos Alberto N; Filho, Antonio Francisco S; Vidal, Carlos Eugênio S; Roxo, Eliana; Nishibe, Christiane; Almeida, Nalvo F; Júnior, Antônio A F; Silva, Marcio R; Neto, José Diomedes B; Cerqueira, Valíria D; Zumárraga, Martín J; Araújo, Flábio R

    2014-01-01

    In the present study, a nested-PCR system, targeting the TbD1 region, involving the performance of conventional PCR followed by real-time PCR, was developed to detect Mycobacterium bovis in bovine/bubaline tissue homogenates. The sensitivity and specificity of the reactions were assessed with DNA samples extracted from tuberculous and non-tuberculous mycobacteria, as well as other actinomycetales species and DNA samples extracted directly from bovine and bubaline tissue homogenates. In terms of analytical sensitivity, the DNA of M. bovis AN5 was detected up to 1.56 ng with conventional PCR, 97.6 pg with real-time PCR, and 1.53 pg with nested-PCR in the reaction mixture. The nested-PCR exhibited 100% analytical specificity for M. bovis when tested with the DNA of reference strains of environmental mycobacteria and closely-related Actinomycetales. A clinical sensitivity value of 76.0% was detected with tissue samples from animals that exhibited positive results in the comparative intradermal tuberculin test (CITT), as well as from those with lesions compatible with tuberculosis (LCT) that rendered positive cultures. A clinical specificity value of 100% was detected with tissue samples from animals with CITT- results, with no visible lesions (NVL) and negative cultures. No significant differences were found between the nested-PCR and culture in terms of detecting CITT+ animals with LCT or with NVL. No significant differences were recorded in the detection of CITT- animals with NVL. However, nested-PCR detected a significantly higher number of positive animals than the culture in the group of animals exhibiting LCT with no previous records of CITT. The use of the nested-PCR assay to detect M. bovis in tissue homogenates provided a rapid diagnosis of bovine and bubaline tuberculosis.

  1. Variable frequency of polyomavirus SV40 and herpesvirus EBV in lymphomas from two different urban population groups in Houston, TX.

    PubMed

    Toracchio, Sonia; Kozinetz, Claudia A; Killen, Deanna E; Sheehan, Andrea M; Banez, Eugenio I; Ittmann, Michael M; Sroller, Vojtech; Butel, Janet S

    2009-10-01

    Studies have reported differing frequencies of detection of polyomavirus simian virus 40 (SV40) in association with human lymphomas. We addressed the hypothesis that SV40 positivity in lymphomas can vary among sampled populations. Archival paraffin-embedded lymphoma specimens (n=171) from patients at two urban hospitals in Houston, TX, USA, were analyzed following a cross-sectional study design. Extracted DNAs were characterized by quantitative polymerase chain reaction for the cellular RNase P gene and for SV40 and herpesvirus Epstein-Barr virus (EBV) sequences. Patient characteristics of the two study populations differed significantly whereas the classification of tumor types studied did not. SV40 DNA was detected more frequently in lymphomas from the public hospital population (10/44, 23%) than in lymphomas from the veterans' hospital (VAMC) (4/127, 3%; P<0.0001). EBV detection in lymphomas also differed between the two groups (17/44, 39% vs. 23/127, 18%; P=0.01). SV40 positivity was associated with a younger age category of VAMC lymphoma patients (P=0.02). Expression of T-antigen was detected by immunohistochemistry in half of lymphomas that contained SV40 DNA. Variation was observed in the quality and quantity of DNA recovered from paraffin-embedded specimens, but there was no difference in recoveries of DNA from samples from the two hospitals. This study demonstrated that, in a direct comparison, the prevalence of SV40 DNA in lymphomas can differ significantly between groups with different demographic distributions.

  2. Guidelines for Head Tactile Communication

    DTIC Science & Technology

    2010-03-01

    significant effects were explored using least significant difference ( LSD ). The mean static force created on the head by the headband was 0.47 N. Due to...differences in thresholds attributable to head location, frequency, and noise condition, and significant effects were explored using LSD . The mean...Stuart, M.; Turman, A. B.; Shaw , J.; Walsh, N.; Nguyen, V. Effects of Aging on Vibration Detection Thresholds at Various Body Regions. BMC Geriatrics

  3. Absolute calibration of a multichannel plate detector for low energy O, O-, and O+

    NASA Astrophysics Data System (ADS)

    Stephen, T. M.; Peko, B. L.

    2000-03-01

    Absolute detection efficiencies of a commercial multichannel plate detector have been measured for O, O+, and O-, impacting at normal incidence for energies ranging from 30-1000 eV. In addition, the detection efficiencies for O relative to its ions are presented, as they may have a more universal application. The absolute detection efficiencies are strongly energy dependent and significant differences are observed for the various charge states at lower energies. The detection efficiencies for the different charge states appear to converge at higher energies. The strongest energy dependence is for O+; the detection efficiency varies by three orders of magnitude across the energy range studied. The weakest dependence is for O-, which varies less than one order of magnitude.

  4. Vision screening in preschool children: comparison of orthoptists and clinical medical officers as primary screeners.

    PubMed Central

    Bolger, P G; Stewart-Brown, S L; Newcombe, E; Starbuck, A

    1991-01-01

    OBJECTIVE--To see if there were differences in referral rates and abnormalities detected from two areas that were operating different preschool vision screening programmes. DESIGN--Cohort study using case notes of referrals. SETTING--Community based secondary referral centres in the county of Avon. PATIENTS--263 referrals from a child population of 7105 in Southmead district, an area that used orthoptists as primary vision screeners; 111 referrals from a child population of 2977 in Weston-super-Mare, an area that used clinical medical officers for screening. MAIN OUTCOME MEASURES--Amblyopia and squint detection rates, together with false positive referral rates. RESULTS--The amblyopia detection rate in Southmead district was significantly higher than in Weston-super-Mare (11/1000 children v 5/1000), as was the detection rate of squint (11/1000 v 3/1000). However, the false positive referral rate from Southmead was significantly lower than that from Weston-super-Mare (9/1000 v 23/1000). CONCLUSION--Preschool vision screening using orthoptists as primary screeners offers a more effective method of detecting visual abnormalities than using clinical medical officers. PMID:1747671

  5. Development of an algorithm for an EEG-based driver fatigue countermeasure.

    PubMed

    Lal, Saroj K L; Craig, Ashley; Boord, Peter; Kirkup, Les; Nguyen, Hung

    2003-01-01

    Fatigue affects a driver's ability to proceed safely. Driver-related fatigue and/or sleepiness are a significant cause of traffic accidents, which makes this an area of great socioeconomic concern. Monitoring physiological signals while driving provides the possibility of detecting and warning of fatigue. The aim of this paper is to describe an EEG-based fatigue countermeasure algorithm and to report its reliability. Changes in all major EEG bands during fatigue were used to develop the algorithm for detecting different levels of fatigue. The software was shown to be capable of detecting fatigue accurately in 10 subjects tested. The percentage of time the subjects were detected to be in a fatigue state was significantly different than the alert phase (P<.01). This is the first countermeasure software described that has shown to detect fatigue based on EEG changes in all frequency bands. Field research is required to evaluate the fatigue software in order to produce a robust and reliable fatigue countermeasure system. The development of the fatigue countermeasure algorithm forms the basis of a future fatigue countermeasure device. Implementation of electronic devices for fatigue detection is crucial for reducing fatigue-related road accidents and their associated costs.

  6. The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz.

    PubMed

    Yang, Lin; Dai, Meng; Xu, Canhua; Zhang, Ge; Li, Weichen; Fu, Feng; Shi, Xuetao; Dong, Xiuzhen

    2017-01-01

    Frequency-difference electrical impedance tomography (fdEIT) reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz). In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects' heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz) significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz) also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection.

  7. The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz

    PubMed Central

    Zhang, Ge; Li, Weichen; Fu, Feng; Shi, Xuetao; Dong, Xiuzhen

    2017-01-01

    Frequency-difference electrical impedance tomography (fdEIT) reconstructs frequency-dependent changes of a complex impedance distribution. It has a potential application in acute stroke detection because there are significant differences in impedance spectra between stroke lesions and normal brain tissues. However, fdEIT suffers from the influences of electrode-skin contact impedance since contact impedance varies greatly with frequency. When using fdEIT to detect stroke, it is critical to know the degree of measurement errors or image artifacts caused by contact impedance. To our knowledge, no study has systematically investigated the frequency spectral properties of electrode-skin contact impedance on human head and its frequency-dependent effects on fdEIT used in stroke detection within a wide frequency band (10 Hz-1 MHz). In this study, we first measured and analyzed the frequency spectral properties of electrode-skin contact impedance on 47 human subjects’ heads within 10 Hz-1 MHz. Then, we quantified the frequency-dependent effects of contact impedance on fdEIT in stroke detection in terms of the current distribution beneath the electrodes and the contact impedance imbalance between two measuring electrodes. The results showed that the contact impedance at high frequencies (>100 kHz) significantly changed the current distribution beneath the electrode, leading to nonnegligible errors in boundary voltages and artifacts in reconstructed images. The contact impedance imbalance at low frequencies (<1 kHz) also caused significant measurement errors. We conclude that the contact impedance has critical frequency-dependent influences on fdEIT and further studies on reducing such influences are necessary to improve the application of fdEIT in stroke detection. PMID:28107524

  8. The Binaural Masking-Level Difference of Mandarin Tone Detection and the Binaural Intelligibility-Level Difference of Mandarin Tone Recognition in the Presence of Speech-Spectrum Noise

    PubMed Central

    Ho, Cheng-Yu; Li, Pei-Chun; Chiang, Yuan-Chuan; Young, Shuenn-Tsong; Chu, Woei-Chyn

    2015-01-01

    Binaural hearing involves using information relating to the differences between the signals that arrive at the two ears, and it can make it easier to detect and recognize signals in a noisy environment. This phenomenon of binaural hearing is quantified in laboratory studies as the binaural masking-level difference (BMLD). Mandarin is one of the most commonly used languages, but there are no publication values of BMLD or BILD based on Mandarin tones. Therefore, this study investigated the BMLD and BILD of Mandarin tones. The BMLDs of Mandarin tone detection were measured based on the detection threshold differences for the four tones of the voiced vowels /i/ (i.e., /i1/, /i2/, /i3/, and /i4/) and /u/ (i.e., /u1/, /u2/, /u3/, and /u4/) in the presence of speech-spectrum noise when presented interaurally in phase (S0N0) and interaurally in antiphase (SπN0). The BILDs of Mandarin tone recognition in speech-spectrum noise were determined as the differences in the target-to-masker ratio (TMR) required for 50% correct tone recognitions between the S0N0 and SπN0 conditions. The detection thresholds for the four tones of /i/ and /u/ differed significantly (p<0.001) between the S0N0 and SπN0 conditions. The average detection thresholds of Mandarin tones were all lower in the SπN0 condition than in the S0N0 condition, and the BMLDs ranged from 7.3 to 11.5 dB. The TMR for 50% correct Mandarin tone recognitions differed significantly (p<0.001) between the S0N0 and SπN0 conditions, at –13.4 and –18.0 dB, respectively, with a mean BILD of 4.6 dB. The study showed that the thresholds of Mandarin tone detection and recognition in the presence of speech-spectrum noise are improved when phase inversion is applied to the target speech. The average BILDs of Mandarin tones are smaller than the average BMLDs of Mandarin tones. PMID:25835987

  9. Electrophysiological gap detection thresholds: effects of age and comparison with a behavioral measure.

    PubMed

    Palmer, Shannon B; Musiek, Frank E

    2014-01-01

    Temporal processing ability has been linked to speech understanding ability and older adults often complain of difficulty understanding speech in difficult listening situations. Temporal processing can be evaluated using gap detection procedures. There is some research showing that gap detection can be evaluated using an electrophysiological procedure. However, there is currently no research establishing gap detection threshold using the N1-P2 response. The purposes of the current study were to 1) determine gap detection thresholds in younger and older normal-hearing adults using an electrophysiological measure, 2) compare the electrophysiological gap detection threshold and behavioral gap detection threshold within each group, and 3) investigate the effect of age on each gap detection measure. This study utilized an older adult group and younger adult group to compare performance on an electrophysiological and behavioral gap detection procedure. The subjects in this study were 11 younger, normal-hearing adults (mean = 22 yrs) and 11 older, normal-hearing adults (mean = 64.36 yrs). All subjects completed an adaptive behavioral gap detection procedure in order to determine their behavioral gap detection threshold (BGDT). Subjects also completed an electrophysiologic gap detection procedure to determine their electrophysiologic gap detection threshold (EGDT). Older adults demonstrated significantly larger gap detection thresholds than the younger adults. However, EGDT and BGDT were not significantly different in either group. The mean difference between EGDT and BGDT for all subjects was 0.43 msec. Older adults show poorer gap detection ability when compared to younger adults. However, this study shows that gap detection thresholds can be measured using evoked potential recordings and yield results similar to a behavioral measure. American Academy of Audiology.

  10. Small target detection based on difference accumulation and Gaussian curvature under complex conditions

    NASA Astrophysics Data System (ADS)

    Zhang, He; Niu, Yanxiong; Zhang, Hao

    2017-12-01

    Small target detection is a significant subject in infrared search and track and other photoelectric imaging systems. The small target is imaged under complex conditions, which contains clouds, horizon and bright part. In this paper, a novel small target detection method is proposed based on difference accumulation, clustering and Gaussian curvature. Difference accumulation varies from regions. Therefore, after obtaining difference accumulations, clustering is applied to determine whether the pixel belongs to the heterogeneous region, and eliminate heterogeneous region. Then Gaussian curvature is used to separate target from the homogeneous region. Experiments are conducted for verification, along with comparisons to several other methods. The experimental results demonstrate that our method has an advantage of 1-2 orders of magnitude on SCRG and BSF than others. Given that the false alarm rate is 1, the detection probability can be approximately 0.9 by using proposed method.

  11. Novel optical strategies for biodetection

    NASA Astrophysics Data System (ADS)

    Sakamuri, Rama M.; Wolfenden, Mark S.; Anderson, Aaron S.; Swanson, Basil I.; Schmidt, Jurgen S.; Mukundan, Harshini

    2013-09-01

    Although bio-detection strategies have significantly evolved in the past decade, they still suffer from many disadvantages. For one, current approaches still require confirmation of pathogen viability by culture, which is the `gold-standard' method, and can take several days to result. Second, current methods typically target protein and nucleic acid signatures and cannot be applied to other biochemical categories of biomarkers (e.g.; lipidated sugars). Lipidated sugars (e.g.; lipopolysaccharide, lipoarabinomannan) are bacterial virulence factors that are significant to pathogenicity. Herein, we present two different optical strategies for biodetection to address these two limitations. We have exploited bacterial iron sequestration mechanisms to develop a simple, specific assay for the selective detection of viable bacteria, without the need for culture. We are currently working on the use of this technology for the differential detection of two different bacteria, using siderophores. Second, we have developed a novel strategy termed `membrane insertion' for the detection of amphiphilic biomarkers (e.g. lipidated glycans) that cannot be detected by conventional approaches. We have extended this technology to the detection of small molecule amphiphilic virulence factors, such as phenolic glycolipid-1 from leprosy, which could not be directly detected before. Together, these strategies address two critical limitations in current biodetection approaches. We are currently working on the optimization of these methods, and their extension to real-world clinical samples.

  12. Machine Learning Techniques for the Detection of Shockable Rhythms in Automated External Defibrillators

    PubMed Central

    Irusta, Unai; Morgado, Eduardo; Aramendi, Elisabete; Ayala, Unai; Wik, Lars; Kramer-Johansen, Jo; Eftestøl, Trygve; Alonso-Atienza, Felipe

    2016-01-01

    Early recognition of ventricular fibrillation (VF) and electrical therapy are key for the survival of out-of-hospital cardiac arrest (OHCA) patients treated with automated external defibrillators (AED). AED algorithms for VF-detection are customarily assessed using Holter recordings from public electrocardiogram (ECG) databases, which may be different from the ECG seen during OHCA events. This study evaluates VF-detection using data from both OHCA patients and public Holter recordings. ECG-segments of 4-s and 8-s duration were analyzed. For each segment 30 features were computed and fed to state of the art machine learning (ML) algorithms. ML-algorithms with built-in feature selection capabilities were used to determine the optimal feature subsets for both databases. Patient-wise bootstrap techniques were used to evaluate algorithm performance in terms of sensitivity (Se), specificity (Sp) and balanced error rate (BER). Performance was significantly better for public data with a mean Se of 96.6%, Sp of 98.8% and BER 2.2% compared to a mean Se of 94.7%, Sp of 96.5% and BER 4.4% for OHCA data. OHCA data required two times more features than the data from public databases for an accurate detection (6 vs 3). No significant differences in performance were found for different segment lengths, the BER differences were below 0.5-points in all cases. Our results show that VF-detection is more challenging for OHCA data than for data from public databases, and that accurate VF-detection is possible with segments as short as 4-s. PMID:27441719

  13. Machine Learning Techniques for the Detection of Shockable Rhythms in Automated External Defibrillators.

    PubMed

    Figuera, Carlos; Irusta, Unai; Morgado, Eduardo; Aramendi, Elisabete; Ayala, Unai; Wik, Lars; Kramer-Johansen, Jo; Eftestøl, Trygve; Alonso-Atienza, Felipe

    2016-01-01

    Early recognition of ventricular fibrillation (VF) and electrical therapy are key for the survival of out-of-hospital cardiac arrest (OHCA) patients treated with automated external defibrillators (AED). AED algorithms for VF-detection are customarily assessed using Holter recordings from public electrocardiogram (ECG) databases, which may be different from the ECG seen during OHCA events. This study evaluates VF-detection using data from both OHCA patients and public Holter recordings. ECG-segments of 4-s and 8-s duration were analyzed. For each segment 30 features were computed and fed to state of the art machine learning (ML) algorithms. ML-algorithms with built-in feature selection capabilities were used to determine the optimal feature subsets for both databases. Patient-wise bootstrap techniques were used to evaluate algorithm performance in terms of sensitivity (Se), specificity (Sp) and balanced error rate (BER). Performance was significantly better for public data with a mean Se of 96.6%, Sp of 98.8% and BER 2.2% compared to a mean Se of 94.7%, Sp of 96.5% and BER 4.4% for OHCA data. OHCA data required two times more features than the data from public databases for an accurate detection (6 vs 3). No significant differences in performance were found for different segment lengths, the BER differences were below 0.5-points in all cases. Our results show that VF-detection is more challenging for OHCA data than for data from public databases, and that accurate VF-detection is possible with segments as short as 4-s.

  14. Persistent organic pollutants and inorganic elements in the Balearic shearwater Puffinus mauretanicus wintering off Portugal.

    PubMed

    Costa, R A; Torres, J; Vingada, J V; Eira, C

    2016-07-15

    This study presents the first data on trace element and organic pollutant concentrations in the Critically Endangered Balearic shearwater Puffinus mauretanicus collected in 2010 and 2011 in Portugal. Trace element levels were below the threshold levels for adverse effects on birds, despite the Hg concentrations in feathers (4.35μg·g-1ww). No significant differences were detected between individuals from 2010 and 2011 except for Se concentrations in liver, feathers and muscle (higher in 2010) and Ag in liver and muscle (higher in 2011). No significant differences were detected in total concentrations of organochlorine compounds in Balearic shearwaters between years, although PCB congeners -101 and -180 presented higher concentrations in individuals from 2010. The PCB congeners -138, -153 and -180, and 4.4-DDE were detected in all individuals. This study on toxic elements and organic pollutants in wintering Balearic shearwaters provides baseline data from which deviations can be detected in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Genetic analysis of children of atomic bomb survivors.

    PubMed Central

    Satoh, C; Takahashi, N; Asakawa, J; Kodaira, M; Kuick, R; Hanash, S M; Neel, J V

    1996-01-01

    Studies are under way for the detection of potential genetic effects of atomic bomb radiation at the DNA level in the children of survivors. In a pilot study, we have examined six minisatellites and five microsatellites in DNA derived from 100 families including 124 children. We detected a total of 28 mutations in three minisatellite loci. The mean mutation rates per locus per gamete in the six minisatellite loci were 1.5% for 65 exposed gametes for which mean parental gonadal dose was 1.9 Sv and 2.0% for 183 unexposed gametes. We detected four mutations in two tetranucleotide repeat sequences but no mutations in three trinucleotide repeat sequences. The mean mutation rate per locus per gamete was o% for the exposed gametes and 0.5% for the unexposed gametes in the five microsatellite loci. No significant differences in the mutation rates between the exposed and the unexposed gametes were detected in these repetitive sequences. Additional loci are being analyzed to increase the power of our study to observe a significant difference in the mutation rates at the 0.05 level of significance. Images Figure 1. Figure 2. Figure 2. Figure 2. Figure 2. Figure 2. Figure 2. PMID:8781374

  16. Comparison of RFFIT tests with different standard sera and testing procedures.

    PubMed

    Yu, Peng-cheng; Noguchi, Akira; Inoue, Satoshi; Tang, Qing; Rayner, Simon; Liang, Guo-dong

    2012-06-01

    The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warren, Lucy M.; Mackenzie, Alistair; Cooke, Julie

    Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into halfmore » of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Conclusions: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection.« less

  18. Differences in Looking at Own- and Other-Race Faces Are Subtle and Analysis-Dependent: An Account of Discrepant Reports.

    PubMed

    Arizpe, Joseph; Kravitz, Dwight J; Walsh, Vincent; Yovel, Galit; Baker, Chris I

    2016-01-01

    The Other-Race Effect (ORE) is the robust and well-established finding that people are generally poorer at facial recognition of individuals of another race than of their own race. Over the past four decades, much research has focused on the ORE because understanding this phenomenon is expected to elucidate fundamental face processing mechanisms and the influence of experience on such mechanisms. Several recent studies of the ORE in which the eye-movements of participants viewing own- and other-race faces were tracked have, however, reported highly conflicting results regarding the presence or absence of differential patterns of eye-movements to own- versus other-race faces. This discrepancy, of course, leads to conflicting theoretical interpretations of the perceptual basis for the ORE. Here we investigate fixation patterns to own- versus other-race (African and Chinese) faces for Caucasian participants using different analysis methods. While we detect statistically significant, though subtle, differences in fixation pattern using an Area of Interest (AOI) approach, we fail to detect significant differences when applying a spatial density map approach. Though there were no significant differences in the spatial density maps, the qualitative patterns matched the results from the AOI analyses reflecting how, in certain contexts, Area of Interest (AOI) analyses can be more sensitive in detecting the differential fixation patterns than spatial density analyses, due to spatial pooling of data with AOIs. AOI analyses, however, also come with the limitation of requiring a priori specification. These findings provide evidence that the conflicting reports in the prior literature may be at least partially accounted for by the differences in the statistical sensitivity associated with the different analysis methods employed across studies. Overall, our results suggest that detection of differences in eye-movement patterns can be analysis-dependent and rests on the assumptions inherent in the given analysis.

  19. Differences in Looking at Own- and Other-Race Faces Are Subtle and Analysis-Dependent: An Account of Discrepant Reports

    PubMed Central

    Arizpe, Joseph; Kravitz, Dwight J.; Walsh, Vincent; Yovel, Galit; Baker, Chris I.

    2016-01-01

    The Other-Race Effect (ORE) is the robust and well-established finding that people are generally poorer at facial recognition of individuals of another race than of their own race. Over the past four decades, much research has focused on the ORE because understanding this phenomenon is expected to elucidate fundamental face processing mechanisms and the influence of experience on such mechanisms. Several recent studies of the ORE in which the eye-movements of participants viewing own- and other-race faces were tracked have, however, reported highly conflicting results regarding the presence or absence of differential patterns of eye-movements to own- versus other-race faces. This discrepancy, of course, leads to conflicting theoretical interpretations of the perceptual basis for the ORE. Here we investigate fixation patterns to own- versus other-race (African and Chinese) faces for Caucasian participants using different analysis methods. While we detect statistically significant, though subtle, differences in fixation pattern using an Area of Interest (AOI) approach, we fail to detect significant differences when applying a spatial density map approach. Though there were no significant differences in the spatial density maps, the qualitative patterns matched the results from the AOI analyses reflecting how, in certain contexts, Area of Interest (AOI) analyses can be more sensitive in detecting the differential fixation patterns than spatial density analyses, due to spatial pooling of data with AOIs. AOI analyses, however, also come with the limitation of requiring a priori specification. These findings provide evidence that the conflicting reports in the prior literature may be at least partially accounted for by the differences in the statistical sensitivity associated with the different analysis methods employed across studies. Overall, our results suggest that detection of differences in eye-movement patterns can be analysis-dependent and rests on the assumptions inherent in the given analysis. PMID:26849447

  20. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    PubMed

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Interpretation of the rainbow color scale for quantitative medical imaging: perceptually linear color calibration (CSDF) versus DICOM GSDF

    NASA Astrophysics Data System (ADS)

    Chesterman, Frédérique; Manssens, Hannah; Morel, Céline; Serrell, Guillaume; Piepers, Bastian; Kimpe, Tom

    2017-03-01

    Medical displays for primary diagnosis are calibrated to the DICOM GSDF1 but there is no accepted standard today that describes how display systems for medical modalities involving color should be calibrated. Recently the Color Standard Display Function3,4 (CSDF), a calibration using the CIEDE2000 color difference metric to make a display as perceptually linear as possible has been proposed. In this work we present the results of a first observer study set up to investigate the interpretation accuracy of a rainbow color scale when a medical display is calibrated to CSDF versus DICOM GSDF and a second observer study set up to investigate the detectability of color differences when a medical display is calibrated to CSDF, DICOM GSDF and sRGB. The results of the first study indicate that the error when interpreting a rainbow color scale is lower for CSDF than for DICOM GSDF with statistically significant difference (Mann-Whitney U test) for eight out of twelve observers. The results correspond to what is expected based on CIEDE2000 color differences between consecutive colors along the rainbow color scale for both calibrations. The results of the second study indicate a statistical significant improvement in detecting color differences when a display is calibrated to CSDF compared to DICOM GSDF and a (non-significant) trend indicating improved detection for CSDF compared to sRGB. To our knowledge this is the first work that shows the added value of a perceptual color calibration method (CSDF) in interpreting medical color images using the rainbow color scale. Improved interpretation of the rainbow color scale may be beneficial in the area of quantitative medical imaging (e.g. PET SUV, quantitative MRI and CT and doppler US), where a medical specialist needs to interpret quantitative medical data based on a color scale and/or detect subtle color differences and where improved interpretation accuracy and improved detection of color differences may contribute to a better diagnosis. Our results indicate that for diagnostic applications involving both grayscale and color images, CSDF should be chosen over DICOM GSDF and sRGB as it assures excellent detection for color images and at the same time maintains DICOM GSDF for grayscale images.

  2. Effects of Packstock Use and Backpackers on Water Quality in Yosemite National Park, California

    NASA Astrophysics Data System (ADS)

    Forrester, H.; Clow, D. W.; Roche, J. W.; Heyvaert, A.

    2016-12-01

    Visitor use, primarily backpacker camping, packstock (horse and mule) trail use, and packstock grazing, in designated Wilderness, increases the potential for negative effects on water quality. To determine the effects of visitor use on water quality in Wilderness in Yosemite National Park, we collected and analyzed surface-water samples for water quality indicators, consisting of fecal indicator bacteria (Escherichia coli), nutrients (nitrogen, phosphorus), suspended sediment concentration (SSC), and hormones (e.g. estrogen compounds) during the summers of 2012-2014. We collected samples upstream and downstream from different types of visitor use at routine intervals (weekly or biweekly) and during storms. Additionally, we sampled upstream and downstream from meadows, and targeted different types of visitor use during a park-wide synoptic sampling campaign (n=63). At packstock stream crossings, statistically significant (P≤0.05) increases in Escherichia coli (E. coli) and SSC occurred downstream from crossings compared to upstream conditions during routine sampling (median difference: 3 CFU 100ml-1, and >0.3 mg l-1, respectively) and during storms (median difference: 32 CFU 100ml-1, and 2.9 mg l-1). At backpacker campsites, during routine sampling, significant increases occurred downstream from backpacker camping for E. coli (median difference: 1 CFU 100ml-1), and estrogen hormones were detected. At packstock grazing areas, which are located in meadows, no significant increases were detected for any of the measured water quality indicators downstream from grazing. Most synoptic sample concentrations were near or below detection limits. Our results indicate that under current use levels: 1) packstock trail use and backpacker camping are associated with detectable effects on water quality, which are most pronounced during storms; 2) increases in water quality indicators were not detected downstream from meadows where packstock were grazed; and 3) environmental processes in meadows provide a valuable ecosystem service by reducing human related sources of microbial contamination.

  3. Prevalence of Cryptosporidium spp., Enterocytozoon bieneusi, Encephalitozoon spp. and Giardia intestinalis in Wild, Semi-Wild and Captive Orangutans (Pongo abelii and Pongo pygmaeus) on Sumatra and Borneo, Indonesia.

    PubMed

    Mynářová, Anna; Foitová, Ivona; Kváč, Martin; Květoňová, Dana; Rost, Michael; Morrogh-Bernard, Helen; Nurcahyo, Wisnu; Nguyen, Cathleen; Supriyadi, Supriyadi; Sak, Bohumil

    2016-01-01

    Orangutans are critically endangered primarily due to loss and fragmentation of their natural habitat. This could bring them into closer contact with humans and increase the risk of zoonotic pathogen transmission. To describe the prevalence and diversity of Cryptosporidium spp., microsporidia and Giardia intestinalis in orangutans at seven sites on Sumatra and Kalimantan, and to evaluate the impact of orangutans' habituation and location on the occurrence of these zoonotic protists. The overall prevalence of parasites in 298 examined animals was 11.1%. The most prevalent microsporidia was Encephalitozoon cuniculi genotype II, found in 21 animals (7.0%). Enterocytozoon bieneusi genotype D (n = 5) and novel genotype Pongo 2 were detected only in six individuals (2.0%). To the best of our knowledge, this is the first report of these parasites in orangutans. Eight animals were positive for Cryptosporidium spp. (2.7%), including C. parvum (n = 2) and C. muris (n = 6). Giardia intestinalis assemblage B, subtype MB6, was identified in a single individual. While no significant differences between the different human contact level groups (p = 0.479-0.670) or between the different islands (p = 0.992) were reported in case of E. bieneusi or E. cuniculi, Cryptosporidium spp. was significantly less frequently detected in wild individuals (p < 2×10-16) and was significantly more prevalent in orangutans on Kalimantan than on Sumatra (p < 2×10-16). Our results revealed that wild orangutans are significantly less frequently infected by Cryptosporidium spp. than captive and semi-wild animals. In addition, this parasite was more frequently detected at localities on Kalimantan. In contrast, we did not detect any significant difference in the prevalence of microsporidia between the studied groups of animals. The sources and transmission modes of infections were not determined, as this would require repeated sampling of individuals, examination of water sources, and sampling of humans and animals sharing the habitat with orangutans.

  4. Serological detection of antibodies to Anaplasma spp., Borrelia burgdorferi sensu lato and Ehrlichia canis and of Dirofilaria immitis antigen in dogs from Costa Rica.

    PubMed

    Montenegro, Víctor M; Bonilla, Marta C; Kaminsky, Darwin; Romero-Zúñiga, Juan José; Siebert, Susanne; Krämer, Friederike

    2017-03-15

    In a study in Costa Rica 314 serum samples from dogs throughout all seven provinces were tested using a commercial kit for the detection of circulating antibodies against Anaplasma spp., Borrelia burgdorferi sensu lato and Ehrlichia canis, and of circulating antigen of Dirofilaria immitis. A total of 6.4% (20/314) and 38.2% (120/314) were positive for Anaplasma spp. (An) and E. canis (Ec) antibodies. Overall, 8.0% (25/314) were positive for D. immitis (Di) antigen. One single dog reacted positive with B. burgdorferi s.l. (Bb) antigen (0.3%, 1/314). E. canis positive dogs were detected in all provinces (highest percentages in Guanacaste, Puntarenas [both significantly different compared to the overall] and Limón). Guanacaste and Puntarenas also showed the highest prevalences of Anaplasma spp. (both significantly different compared to the overall). The highest prevalence of D. immitis was detected in Puntarenas (significantly different compared to the overall). Double pathogen exposure (Ec plus An; Ec plus Di; Ec plus Bb) were recorded in 8.9% (28/314). Two dogs showed a triple pathogen exposure (0.6%, 2/314; An, Ec and Di). There was a significant difference between male (11.5%, 18/156) and female (4.4%, 7/158) animals for D. immitis positive results. There was also a significant difference between breed and no breed dogs regarding the characteristics of a general positive test, as well as seropositivity to the single pathogens of Anaplasma spp., E. canis and D. immitis. Finally there was a significant difference in the presence of clinical signs again regarding the characteristics of a general positive test, as well as seropositivity to Anaplasma spp., E. canis and D. immitis. Practitioners in Costa Rica should be aware of the canine vector-borne diseases mentioned as dogs are at risk of becoming infected. Concerning the positive B. burgdorferi s.l. dog, an autochthonous occurrence cannot be confirmed due to a history of adoption and an unusual tattoo number. Veterinary advice to protect dogs and limit transmission of vector-borne pathogens, also to humans, by using prophylactic measures is strongly recommended. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Neuroanatomical correlates of biological motion detection.

    PubMed

    Gilaie-Dotan, Sharon; Kanai, Ryota; Bahrami, Bahador; Rees, Geraint; Saygin, Ayse P

    2013-02-01

    Biological motion detection is both commonplace and important, but there is great inter-individual variability in this ability, the neural basis of which is currently unknown. Here we examined whether the behavioral variability in biological motion detection is reflected in brain anatomy. Perceptual thresholds for detection of biological motion and control conditions (non-biological object motion detection and motion coherence) were determined in a group of healthy human adults (n=31) together with structural magnetic resonance images of the brain. Voxel based morphometry analyzes revealed that gray matter volumes of left posterior superior temporal sulcus (pSTS) and left ventral premotor cortex (vPMC) significantly predicted individual differences in biological motion detection, but showed no significant relationship with performance on the control tasks. Our study reveals a neural basis associated with the inter-individual variability in biological motion detection, reliably linking the neuroanatomical structure of left pSTS and vPMC with biological motion detection performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Design and application of a structured phantom for detection performance comparison between breast tomosynthesis and digital mammography

    NASA Astrophysics Data System (ADS)

    Cockmartin, L.; Marshall, N. W.; Zhang, G.; Lemmens, K.; Shaheen, E.; Van Ongeval, C.; Fredenberg, E.; Dance, D. R.; Salvagnini, E.; Michielsen, K.; Bosmans, H.

    2017-02-01

    This paper introduces and applies a structured phantom with inserted target objects for the comparison of detection performance of digital breast tomosynthesis (DBT) against 2D full field digital mammography (FFDM). The phantom consists of a 48 mm thick breast-shaped polymethyl methacrylate (PMMA) container filled with water and PMMA spheres of different diameters. Three-dimensionally (3D) printed spiculated masses (diameter range: 3.8-9.7 mm) and non-spiculated masses (1.6-6.2 mm) along with microcalcifications (90-250 µm) were inserted as targets. Reproducibility of the phantom application was studied on a single system using 30 acquisitions. Next, the phantom was evaluated on five different combined FFDM & DBT systems and target detection was compared for FFDM and DBT modes. Ten phantom images in both FFDM and DBT modes were acquired on these 5 systems using automatic exposure control. Five readers evaluated target detectability. Images were read with the four-alternative forced-choice (4-AFC) paradigm, with always one segment including a target and 3 normal background segments. The percentage of correct responses (PC) was assessed based on 10 trials of each reader for each object type, size and imaging modality. Additionally, detection threshold diameters at 62.5 PC were assessed via non-linear regression fitting of the psychometric curve. The reproducibility study showed no significant differences in PC values. Evaluation of target detection in FFDM showed that microcalcification detection thresholds ranged between 110 and 118 µm and were similar compared to the detection in DBT (range of 106-158 µm). In DBT, detection of both mass types increased significantly (p  =  0.0001 and p  =  0.0002 for non-spiculated and spiculated masses respectively) compared to FFDM, achieving almost 100% detection for all spiculated mass diameters. In conclusion, a structured phantom with inserted targets was able to show evidence for detectability differences between FFDM and DBT modes for five commercial systems. This phantom has potential for application in task-based assessment at acceptance and commissioning testing of DBT systems.

  7. What difference reveals about similarity.

    PubMed

    Sagi, Eyal; Gentner, Dedre; Lovett, Andrew

    2012-08-01

    Detecting that two images are different is faster for highly dissimilar images than for highly similar images. Paradoxically, we showed that the reverse occurs when people are asked to describe how two images differ--that is, to state a difference between two images. Following structure-mapping theory, we propose that this disassociation arises from the multistage nature of the comparison process. Detecting that two images are different can be done in the initial (local-matching) stage, but only for pairs with low overlap; thus, "different" responses are faster for low-similarity than for high-similarity pairs. In contrast, identifying a specific difference generally requires a full structural alignment of the two images, and this alignment process is faster for high-similarity pairs. We described four experiments that demonstrate this dissociation and show that the results can be simulated using the Structure-Mapping Engine. These results pose a significant challenge for nonstructural accounts of similarity comparison and suggest that structural alignment processes play a significant role in visual comparison. Copyright © 2012 Cognitive Science Society, Inc.

  8. The Effects of Soil Texture on the Ability of Human Remains Detection Dogs to Detect Buried Human Remains.

    PubMed

    Alexander, Michael B; Hodges, Theresa K; Wescott, Daniel J; Aitkenhead-Peterson, Jacqueline A

    2016-05-01

    Despite technological advances, human remains detection (HRD) dogs still remain one of the best tools for locating clandestine graves. However, soil texture may affect the escape of decomposition gases and therefore the effectiveness of HDR dogs. Six nationally credentialed HRD dogs (three HRD only and three cross-trained) were evaluated on novel buried human remains in contrasting soils, a clayey and a sandy soil. Search time and accuracy were compared for the clayey soil and sandy soil to assess odor location difficulty. Sandy soil (p < 0.001) yielded significantly faster trained response times, but no significant differences were found in performance accuracy between soil textures or training method. Results indicate soil texture may be significant factor in odor detection difficulty. Prior knowledge of soil texture and moisture may be useful for search management and planning. Appropriate adjustments to search segment sizes, sweep widths and search time allotment depending on soil texture may optimize successful detection. © 2016 American Academy of Forensic Sciences.

  9. Correlation between chemotherapy resistance in osteosarcoma patients and PAK5 and Ezrin gene expression

    PubMed Central

    Liu, Qian; Xu, Bo; Zhou, Wanshan

    2018-01-01

    The correlation between PAK5 (P21-activated kinase 5) and Ezrin gene expression and chemotherapy resistance of osteosarcoma patients was investigated. The cisplatin (CDDP)-resistance model of osteosarcoma cells SOSP-9607/CDDP was established to detect the cell growth curve. Methyl thiazolyl tetrazolium (MTT) assay was used to detect the drug resistance of cells to chemotherapy drugs. Transwell assay was used to detect the invasive capacity of cells. Semi-quantitative PCR (qPCR) was used to detect the mRNA expression levels in the drug resistance-related genes PAK5 and Ezrin. Western blot analysis was used to detect the protein expression levels in PAK5 and Ezrin. Tumor tissues were taken from the osteosarcoma patients with chemotherapy resistance to detect the expression levels of PAK5 and Ezrin via immunohistochemical detection, and the correlation between PAK5 and Ezrin expressions was studied. The results of MTT assay showed that the growth rate of SOSP-9607 was similar to that of SOSP-9607/CDDP, and the difference was not statistically significant (P>0.05). The sensitivity of SOSP-9607 to CDDP was significantly higher than that of SOSP-9607/CDDP, and the difference was statistically significant (P<0.01). Transwell assay showed that the migration capacity of SOSP-9607/CDDP was significantly better than that of SOSP-9607 (P<0.01), indicating that the drug resistance cell lines of osteosarcoma were constructed successfully. Semi-qPCR and western blot analysis showed that the protein expression levels in PAK5 and Ezrin in SOSP-9607/CDDP were significantly higher than those in SOSP-9607 (P<0.01). The results of immunohistochemistry showed that the expression quantities of PAK5 and Ezrin in osteosarcoma tissues were significantly higher than those in para-tumor tissues (P<0.01). Pearson's correlation analysis showed that expression of PAK5 and Ezrin was positively correlated (r=0.197, P=0.023). The osteosarcoma resistance is closely related to the expression levels of PAK5 and Ezrin genes. Thus, PAK5 and Ezrin genes may affect the tolerance of osteosarcoma patients to chemotherapy drugs during treatment via the synergistic effect. PMID:29391894

  10. Advanced imaging technologies increase detection of dysplasia and neoplasia in patients with Barrett's esophagus: a meta-analysis and systematic review.

    PubMed

    Qumseya, Bashar J; Wang, Haibo; Badie, Nicole; Uzomba, Rosemary N; Parasa, Sravanthi; White, Donna L; Wolfsen, Herbert; Sharma, Prateek; Wallace, Michael B

    2013-12-01

    US guidelines recommend surveillance of patients with Barrett's esophagus (BE) to detect dysplasia. BE conventionally is monitored via white-light endoscopy (WLE) and a collection of random biopsy specimens. However, this approach does not definitively or consistently detect areas of dysplasia. Advanced imaging technologies can increase the detection of dysplasia and cancer. We investigated whether these imaging technologies can increase the diagnostic yield for the detection of neoplasia in patients with BE, compared with WLE and analysis of random biopsy specimens. We performed a systematic review, using Medline and Embase, to identify relevant peer-review studies. Fourteen studies were included in the final analysis, with a total of 843 patients. Our metameter (estimate) of interest was the paired-risk difference (RD), defined as the difference in yield of the detection of dysplasia or cancer using advanced imaging vs WLE. The estimated paired-RD and 95% confidence interval (CI) were obtained using random-effects models. Heterogeneity was assessed by means of the Q statistic and the I(2) statistic. An exploratory meta-regression was performed to look for associations between the metameter and potential confounders or modifiers. Overall, advanced imaging techniques increased the diagnostic yield for detection of dysplasia or cancer by 34% (95% CI, 20%-56%; P < .0001). A subgroup analysis showed that virtual chromoendoscopy significantly increased the diagnostic yield (RD, 0.34; 95% CI, 0.14-0.56; P < .0001). The RD for chromoendoscopy was 0.35 (95% CI, 0.13-0.56; P = .0001). There was no significant difference between virtual chromoendoscopy and chromoendoscopy, based on Student t test analysis (P = .45). Based on a meta-analysis, advanced imaging techniques such as chromoendoscopy or virtual chromoendoscopy significantly increase the diagnostic yield for identification of dysplasia or cancer in patients with BE. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  11. Canine olfactory receptor gene polymorphism and its relation to odor detection performance by sniffer dogs.

    PubMed

    Lesniak, Anna; Walczak, Marta; Jezierski, Tadeusz; Sacharczuk, Mariusz; Gawkowski, Maciej; Jaszczak, Kazimierz

    2008-01-01

    The outstanding sensitivity of the canine olfactory system has been acknowledged by using sniffer dogs in military and civilian service for detection of a variety of odors. It is hypothesized that the canine olfactory ability is determined by polymorphisms in olfactory receptor (OR) genes. We investigated 5 OR genes for polymorphic sites which might affect the olfactory ability of service dogs in different fields of specific substance detection. All investigated OR DNA sequences proved to have allelic variants, the majority of which lead to protein sequence alteration. Homozygous individuals at 2 gene loci significantly differed in their detection skills from other genotypes. This suggests a role of specific alleles in odor detection and a linkage between single-nucleotide polymorphism and odor recognition efficiency.

  12. [Accuracy of computer aided measurement for detecting dental proximal caries lesions in images of cone-beam computed tomography].

    PubMed

    Zhang, Z L; Li, J P; Li, G; Ma, X C

    2017-02-09

    Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the diagnostic value of CBCT images.

  13. [Efficacy and safety of ultrasound-guided or neurostimulator-guided bilateral axillary brachial plexus block].

    PubMed

    Xu, C S; Zhao, X L; Zhou, H B; Qu, Z J; Yang, Q G; Wang, H J; Wang, G

    2017-10-17

    Objective: To explore the efficacy and safety of bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator. Methods: From February 2012 to April 2014, 120 patients undergoing bilateral hand/forearm surgery in Beijing Jishuitan Hospital were enrolled and anaesthetized with bilateral axillary brachial plexus block. All patients were divided into two groups randomly using random number table: the ultrasound-guided group (group U, n =60) and the neurostimulator-guidedgroup (group N, n =60). The block was performed with 0.5% ropivacaine. Patients' age, sex and operation duration were recorded. Moreover, success rate, performance time, onset of sensor and motor block, performance pain, patient satisfaction degree and the incidence of related complications were also documented. Venous samples were collected at selected time points and the total and the plasma concentrations of ropivacaine were analyzed with HPLC. Results: The performance time, the onset of sensor block and the onset of motor block of group U were (8.2±1.5), (14.2± 2.2)and (24.0±3.5)min respectively, which were markedly shorter than those in group N( (14.6±3.9), (19.9±3.8), (28.8±4.2)min, respectively), and the differences were statistically significant( t =11.74, 10.09, 6.73, respectively, all P <0.01). The performance pain score of group N was (25.5± 13.2), which was obviously more serious than group U (31.7± 11.2) and a significant statistical difference was detected ( t =2.856, P <0.05). The patient satisfaction degree of group U was 95.0%, which was significantly higher than group N (83.3%) and a markedly statistical difference was detected (χ(2)=4.227, P <0.05). Fifty min after performance, the total plasma concentration of ropivacaine of group U was(1.76±0.48)mg/L, which was significantly lower than group N (1.88±0.53)mg/L and a significant statistical difference was detected ( t =2.43, P <0.05), while no significant differences were detected at the other time points between two groups ( P >0.05). No analgesic was superadded and no other anesthesia methods were applied. No complications were detected perioperatively. Conclusions: The bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator are both effective and safe for bilateral hand/forearm surgery. However, the ultrasound-guided block may be more clinically beneficial because of its shorter performance time, rapid onset and higher patient satisfaction degree.

  14. Temporal Cytokine Profiles in Severely Burned Patients: A Comparison of Adults and Children

    PubMed Central

    Finnerty, Celeste C; Jeschke, Marc G; Herndon, David N; Gamelli, Richard; Gibran, Nicole; Klein, Matthew; Silver, Geoff; Arnoldo, Brett; Remick, Daniel; Tompkins, Ronald G

    2008-01-01

    A severe burn leads to hypermetabolism and catabolism resulting in compromised function and structural changes of essential organs. The release of cytokines has been implicated in this hypermetabolic response. The severity of the hypermetabolic response following burn injury increases with age, as does the mortality rate. Due to the relationship between the hypermetabolic and inflammatory responses, we sought to compare the plasma cytokine profiles following a severe burn in adults and in children. We enrolled 25 adults and 24 children who survived a flame burn covering more than 20% of total body surface area (TBSA). The concentrations of 22 cytokines were measured using the Linco multiplex array system (St. Charles, MO, USA). Large perturbations in the expression of pro- and anti-inflammatory cytokines were seen following thermal injury. During the first week following burn injury, IFN-γ, IL-10, IL-17, IL-4, IL-6, and IL-8 were detected at significantly higher levels in adults compared with children, P < 0.05. Significant differences were measured during the second week post-burn for IL-1β (higher in children) and IL-5 (higher in adults), P < 0.05. IL-18 was more abundant in children compared with adults during the third week post-burn, P < 0.05. Between post-burn d 21 and d 66, IL-1α was detected at higher concentrations in pediatric compared with adult patients, P < 0.05. Only GM-CSF expression was significantly different at all time points; it was detected at lower levels in pediatric patients, P < 0.05. Eotaxin, G-CSF, IL-13, IL-15, IP-10, MCP-1, and MIP-1α were detected at significantly different concentrations in adult compared with pediatric patients at multiple time points, P < 0.05. There were no differences in IL-12, IL-2, IL-7, or TNF levels in adult compared with pediatric burn patients at any of these time points. Following severe flame burns, the cytokine profiles in pediatric patients differ compared with those in adult patients, which may provide insight with respect to the higher morbidity rate in adults. Furthermore, the dramatic discrepancies observed in plasma cytokine detection between children and adults suggest that these two patient populations may benefit from different therapeutic interventions to achieve attenuation of the post-burn inflammatory response. PMID:18548133

  15. Effect of varying displays and room illuminance on caries diagnostic accuracy in digital dental radiographs.

    PubMed

    Pakkala, T; Kuusela, L; Ekholm, M; Wenzel, A; Haiter-Neto, F; Kortesniemi, M

    2012-01-01

    In clinical practice, digital radiographs taken for caries diagnostics are viewed on varying types of displays and usually in relatively high ambient lighting (room illuminance) conditions. Our purpose was to assess the effect of room illuminance and varying display types on caries diagnostic accuracy in digital dental radiographs. Previous studies have shown that the diagnostic accuracy of caries detection is significantly better in reduced lighting conditions. Our hypothesis was that higher display luminance could compensate for this in higher ambient lighting conditions. Extracted human teeth with approximal surfaces clinically ranging from sound to demineralized were radiographed and evaluated by 3 observers who detected carious lesions on 3 different types of displays in 3 different room illuminance settings ranging from low illumination, i.e. what is recommended for diagnostic viewing, to higher illumination levels corresponding to those found in an average dental office. Sectioning and microscopy of the teeth validated the presence or absence of a carious lesion. Sensitivity, specificity and accuracy were calculated for each modality and observer. Differences were estimated by analyzing the binary data assuming the added effects of observer and modality in a generalized linear model. The observers obtained higher sensitivities in lower illuminance settings than in higher illuminance settings. However, this was related to a reduction in specificity, which meant that there was no significant difference in overall accuracy. Contrary to our hypothesis, there were no significant differences between the accuracy of different display types. Therefore, different displays and room illuminance levels did not affect the overall accuracy of radiographic caries detection. Copyright © 2012 S. Karger AG, Basel.

  16. Comparison of computed radiography and conventional radiography in detection of small volume pneumoperitoneum.

    PubMed

    Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret

    2008-01-01

    The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.

  17. Optimised padlock probe ligation and microarray detection of multiple (non-authorised) GMOs in a single reaction

    PubMed Central

    Prins, Theo W; van Dijk, Jeroen P; Beenen, Henriek G; Van Hoef, AM Angeline; Voorhuijzen, Marleen M; Schoen, Cor D; Aarts, Henk JM; Kok, Esther J

    2008-01-01

    Background To maintain EU GMO regulations, producers of new GM crop varieties need to supply an event-specific method for the new variety. As a result methods are nowadays available for EU-authorised genetically modified organisms (GMOs), but only to a limited extent for EU-non-authorised GMOs (NAGs). In the last decade the diversity of genetically modified (GM) ingredients in food and feed has increased significantly. As a result of this increase GMO laboratories currently need to apply many different methods to establish to potential presence of NAGs in raw materials and complex derived products. Results In this paper we present an innovative method for detecting (approved) GMOs as well as the potential presence of NAGs in complex DNA samples containing different crop species. An optimised protocol has been developed for padlock probe ligation in combination with microarray detection (PPLMD) that can easily be scaled up. Linear padlock probes targeted against GMO-events, -elements and -species have been developed that can hybridise to their genomic target DNA and are visualised using microarray hybridisation. In a tenplex PPLMD experiment, different genomic targets in Roundup-Ready soya, MON1445 cotton and Bt176 maize were detected down to at least 1%. In single experiments, the targets were detected down to 0.1%, i.e. comparable to standard qPCR. Conclusion Compared to currently available methods this is a significant step forward towards multiplex detection in complex raw materials and derived products. It is shown that the PPLMD approach is suitable for large-scale detection of GMOs in real-life samples and provides the possibility to detect and/or identify NAGs that would otherwise remain undetected. PMID:19055784

  18. Optimised padlock probe ligation and microarray detection of multiple (non-authorised) GMOs in a single reaction.

    PubMed

    Prins, Theo W; van Dijk, Jeroen P; Beenen, Henriek G; Van Hoef, Am Angeline; Voorhuijzen, Marleen M; Schoen, Cor D; Aarts, Henk J M; Kok, Esther J

    2008-12-04

    To maintain EU GMO regulations, producers of new GM crop varieties need to supply an event-specific method for the new variety. As a result methods are nowadays available for EU-authorised genetically modified organisms (GMOs), but only to a limited extent for EU-non-authorised GMOs (NAGs). In the last decade the diversity of genetically modified (GM) ingredients in food and feed has increased significantly. As a result of this increase GMO laboratories currently need to apply many different methods to establish to potential presence of NAGs in raw materials and complex derived products. In this paper we present an innovative method for detecting (approved) GMOs as well as the potential presence of NAGs in complex DNA samples containing different crop species. An optimised protocol has been developed for padlock probe ligation in combination with microarray detection (PPLMD) that can easily be scaled up. Linear padlock probes targeted against GMO-events, -elements and -species have been developed that can hybridise to their genomic target DNA and are visualised using microarray hybridisation.In a tenplex PPLMD experiment, different genomic targets in Roundup-Ready soya, MON1445 cotton and Bt176 maize were detected down to at least 1%. In single experiments, the targets were detected down to 0.1%, i.e. comparable to standard qPCR. Compared to currently available methods this is a significant step forward towards multiplex detection in complex raw materials and derived products. It is shown that the PPLMD approach is suitable for large-scale detection of GMOs in real-life samples and provides the possibility to detect and/or identify NAGs that would otherwise remain undetected.

  19. DNA hybridization assay for detection of Salmonella in foods: collaborative study.

    PubMed

    Flowers, R S; Klatt, M J; Mozola, M A; Curiale, M S; Gabis, D A; Silliker, J H

    1987-01-01

    A collaborative study was performed in 11 laboratories to validate a DNA hybridization (DNAH) procedure for detection of Salmonella in foods. The DNAH procedure was compared to the standard culture method for detection of Salmonella in 6 foods: ground pepper, soy flour, dry whole egg, milk chocolate, nonfat dry milk, and raw deboned turkey. With the exception of turkey which was naturally contaminated, uninoculated and inoculated samples of each food group were analyzed. Results for the DNAH method were significantly better than for the standard culture method at the 5% probability level for the detection of Salmonella in turkey. There was no significant difference between the methods for the other 5 foods. The method has been adopted official first action.

  20. Action Tendency Emotions Evoked by Memorable Breast Cancer Messages and Their Association With Prevention and Detection Behaviors

    PubMed Central

    Smith, Sandi W.; Hamel, Lauren M; Kotowski, Michael R.; Nazione, Samantha; LaPlante, Carolyn; Atkin, Charles K.; Stohl, Cynthia; Skubisz, Christine

    2010-01-01

    Memorable messages about breast cancer sent by different sources, such as friends and family members, were analyzed for the action tendency emotions that they evoked. Negative emotions of fear, sadness, and anger, and positive emotions of hope and relief were analyzed for their associations with prevention and detection breast cancer behaviors. Messages that evoked fear were significantly more likely to be associated with detection behaviors, whereas messages that evoked relief were significantly less likely to be associated with detection behaviors than messages that did not evoke these emotions. These results are consistent with control theory and also show that friends and family are important sources of memorable messages about breast cancer. PMID:21153990

  1. Sonora exploratory study for the detection of wheat-leaf rust

    NASA Technical Reports Server (NTRS)

    Payne, R. W. (Principal Investigator)

    1980-01-01

    The applicability of LANDSAT remote sensing technology to the detection of a wheat-leaf-rust epidemic in Sonora, Mexico, during 1977 was investigated. LANDSAT data acquired during crop years 1975-76 and 1976-77 were clustered, classified, and analyzed in order to detect agricultural changes. Analysis of 1977 data indicates a significant proportion of the identified wheat is stressed (potentially rust-infected). Additional analyses show a significant increase in fallowing during the year, as well as a substantial decrease in reservoir levels in the Sonora agricultural region. Ground observations are required to substantiate these analyses. The possibility exists that heat-rust is not LANDSAT detectable and that the clusters identified as containing stressed signatures represent different varieties of wheat or perhaps nonwheat crops.

  2. Automated detection of focal cortical dysplasia type II with surface-based magnetic resonance imaging postprocessing and machine learning.

    PubMed

    Jin, Bo; Krishnan, Balu; Adler, Sophie; Wagstyl, Konrad; Hu, Wenhan; Jones, Stephen; Najm, Imad; Alexopoulos, Andreas; Zhang, Kai; Zhang, Jianguo; Ding, Meiping; Wang, Shuang; Wang, Zhong Irene

    2018-05-01

    Focal cortical dysplasia (FCD) is a major pathology in patients undergoing surgical resection to treat pharmacoresistant epilepsy. Magnetic resonance imaging (MRI) postprocessing methods may provide essential help for detection of FCD. In this study, we utilized surface-based MRI morphometry and machine learning for automated lesion detection in a mixed cohort of patients with FCD type II from 3 different epilepsy centers. Sixty-one patients with pharmacoresistant epilepsy and histologically proven FCD type II were included in the study. The patients had been evaluated at 3 different epilepsy centers using 3 different MRI scanners. T1-volumetric sequence was used for postprocessing. A normal database was constructed with 120 healthy controls. We also included 35 healthy test controls and 15 disease test controls with histologically confirmed hippocampal sclerosis to assess specificity. Features were calculated and incorporated into a nonlinear neural network classifier, which was trained to identify lesional cluster. We optimized the threshold of the output probability map from the classifier by performing receiver operating characteristic (ROC) analyses. Success of detection was defined by overlap between the final cluster and the manual labeling. Performance was evaluated using k-fold cross-validation. The threshold of 0.9 showed optimal sensitivity of 73.7% and specificity of 90.0%. The area under the curve for the ROC analysis was 0.75, which suggests a discriminative classifier. Sensitivity and specificity were not significantly different for patients from different centers, suggesting robustness of performance. Correct detection rate was significantly lower in patients with initially normal MRI than patients with unequivocally positive MRI. Subgroup analysis showed the size of the training group and normal control database impacted classifier performance. Automated surface-based MRI morphometry equipped with machine learning showed robust performance across cohorts from different centers and scanners. The proposed method may be a valuable tool to improve FCD detection in presurgical evaluation for patients with pharmacoresistant epilepsy. Wiley Periodicals, Inc. © 2018 International League Against Epilepsy.

  3. Post-harvest decay in fresh-cut lettuce

    USDA-ARS?s Scientific Manuscript database

    Shelf-life of fresh-cut lettuce was assessed in two mapping population (Salinas 88 x La Brillante, and Pavane x Parade. The most significant QTL was detected in both populations on linkage group 4. This QTL was detected in seven experiments grown in different environments. Molecular markers are bein...

  4. Human Evoked Cortical Activity to Silent Gaps in Noise: Effects of Age, Attention, and Cortical Processing Speed

    PubMed Central

    Harris, Kelly C.; Wilson, Sara; Eckert, Mark A.; Dubno, Judy R.

    2011-01-01

    Objectives The goal of this study was to examine the degree to which age-related differences in early or automatic levels of auditory processing and attention-related processes explain age-related differences in auditory temporal processing. We hypothesized that age-related differences in attention and cognition compound age-related differences at automatic levels of processing, contributing to the robust age effects observed during challenging listening tasks. Design We examined age-related and individual differences in cortical event-related potential (ERP) amplitudes and latencies, processing speed, and gap detection from twenty-five younger and twenty-five older adults with normal hearing. ERPs were elicited by brief silent periods (gaps) in an otherwise continuous broadband noise and were measured under two listening conditions, passive and active. During passive listening, participants ignored the stimulus and read quietly. During active listening, participants button pressed each time they detected a gap. Gap detection (percent detected) was calculated for each gap duration during active listening (3, 6, 9, 12 and 15 ms). Processing speed was assessed using the Purdue Pegboard test and the Connections Test. Repeated measures ANOVAs assessed effects of age on gap detection, processing speed, and ERP amplitudes and latencies. An “attention modulation” construct was created using linear regression to examine the effects of attention while controlling for age-related differences in auditory processing. Pearson correlation analyses assessed the extent to which attention modulation, ERPs, and processing speed predicted behavioral gap detection. Results: Older adults had significantly poorer gap detection and slower processing speed than younger adults. Even after adjusting for poorer gap detection, the neurophysiological response to gap onset was atypical in older adults with reduced P2 amplitudes and virtually absent N2 responses. Moreover, individual differences in attention modulation of P2 response latencies and N2 amplitudes predicted gap detection and processing speed in older adults. That is, older adults with P2 latencies that decreased and N2 amplitudes that increased with active listening had faster processing speed and better gap detection than those older adults whose P2 latencies increased and N2 amplitudes decreased with attention Conclusions Results from the current study are broadly consistent with previous findings that older adults exhibit significantly poorer gap detection than younger adults in challenging tasks. Even after adjusting for poorer gap detection, older and younger adults showed robust differences in their electrophysiological responses to sound offset. Furthermore, the degree to which attention modulated the ERP was associated with individual variation in measures of processing speed and gap detection. Taken together, these results suggests an age-related deficit in early or automatic levels of auditory temporal processing and that some older adults may be less able to compensate for declines in processing by attending to the stimulus. These results extend our previous findings and support the hypothesis that age-related differences in cognitive or attention-related processing, including processing speed, contribute to an age-related decrease in gap detection. PMID:22374321

  5. diffHic: a Bioconductor package to detect differential genomic interactions in Hi-C data.

    PubMed

    Lun, Aaron T L; Smyth, Gordon K

    2015-08-19

    Chromatin conformation capture with high-throughput sequencing (Hi-C) is a technique that measures the in vivo intensity of interactions between all pairs of loci in the genome. Most conventional analyses of Hi-C data focus on the detection of statistically significant interactions. However, an alternative strategy involves identifying significant changes in the interaction intensity (i.e., differential interactions) between two or more biological conditions. This is more statistically rigorous and may provide more biologically relevant results. Here, we present the diffHic software package for the detection of differential interactions from Hi-C data. diffHic provides methods for read pair alignment and processing, counting into bin pairs, filtering out low-abundance events and normalization of trended or CNV-driven biases. It uses the statistical framework of the edgeR package to model biological variability and to test for significant differences between conditions. Several options for the visualization of results are also included. The use of diffHic is demonstrated with real Hi-C data sets. Performance against existing methods is also evaluated with simulated data. On real data, diffHic is able to successfully detect interactions with significant differences in intensity between biological conditions. It also compares favourably to existing software tools on simulated data sets. These results suggest that diffHic is a viable approach for differential analyses of Hi-C data.

  6. Comparison of public peak detection algorithms for MALDI mass spectrometry data analysis.

    PubMed

    Yang, Chao; He, Zengyou; Yu, Weichuan

    2009-01-06

    In mass spectrometry (MS) based proteomic data analysis, peak detection is an essential step for subsequent analysis. Recently, there has been significant progress in the development of various peak detection algorithms. However, neither a comprehensive survey nor an experimental comparison of these algorithms is yet available. The main objective of this paper is to provide such a survey and to compare the performance of single spectrum based peak detection methods. In general, we can decompose a peak detection procedure into three consequent parts: smoothing, baseline correction and peak finding. We first categorize existing peak detection algorithms according to the techniques used in different phases. Such a categorization reveals the differences and similarities among existing peak detection algorithms. Then, we choose five typical peak detection algorithms to conduct a comprehensive experimental study using both simulation data and real MALDI MS data. The results of comparison show that the continuous wavelet-based algorithm provides the best average performance.

  7. Analysis of user characteristics related to drop-off detection with long cane

    PubMed Central

    Kim, Dae Shik; Emerson, Robert Wall; Curtis, Amy

    2010-01-01

    This study examined how user characteristics affect drop-off detection with the long cane. A mixed-measures design with block randomization was used for the study, in which 32 visually impaired adults attempted to detect the drop-offs using different cane techniques. Younger cane users detected drop-offs significantly more reliably (mean +/− standard deviation = 74.2% +/− 11.2% of the time) than older cane users (60.9% +/− 10.8%), p = 0.009. The drop-off detection threshold of the younger participants (5.2 +/− 2.1 cm) was also statistically significantly smaller than that of the older participants (7.9 +/− 2.2 cm), p = 0.007. Those with early-onset visual impairment (78.0% +/− 9.0%) also detected drop-offs significantly more reliably than those with later-onset visual impairment (67.3% +/− 12.4%), p = 0.01. No interaction occurred between examined user characteristics (age and age at onset of visual impairment) and the type of cane technique used in drop-off detection. The findings of the study may help orientation and mobility specialists select appropriate cane techniques in accordance with the cane user’s age and onset of visual impairment. PMID:20665349

  8. Model-based iterative reconstruction in low-dose CT colonography-feasibility study in 65 patients for symptomatic investigation.

    PubMed

    Vardhanabhuti, Varut; James, Julia; Nensey, Rehaan; Hyde, Christopher; Roobottom, Carl

    2015-05-01

    To compare image quality on computed tomographic colonography (CTC) acquired at standard dose (STD) and low dose (LD) using filtered-back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) techniques. A total of 65 symptomatic patients were prospectively enrolled for the study and underwent STD and LD CTC with filtered-back projection, adaptive statistical iterative reconstruction, and MBIR to allow direct per-patient comparison. Objective image noise, subjective image analyses, and polyp detection were assessed. Objective image noise analysis demonstrates significant noise reduction using MBIR technique (P < .05) despite being acquired at lower doses. Subjective image analyses were superior for LD MBIR in all parameters except visibility of extracolonic lesions (two-dimensional) and visibility of colonic wall (three-dimensional) where there were no significant differences. There was no significant difference in polyp detection rates (P > .05). Doses: LD (dose-length product, 257.7), STD (dose-length product, 483.6). LD MBIR CTC objectively shows improved image noise using parameters in our study. Subjectively, image quality is maintained. Polyp detection shows no significant difference but because of small numbers needs further validation. Average dose reduction of 47% can be achieved. This study confirms feasibility of using MBIR in this context of CTC in symptomatic population. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  9. Frequency of Testing to Detect Visual Field Progression Derived Using a Longitudinal Cohort of Glaucoma Patients.

    PubMed

    Wu, Zhichao; Saunders, Luke J; Daga, Fábio B; Diniz-Filho, Alberto; Medeiros, Felipe A

    2017-06-01

    To determine the time required to detect statistically significant progression for different rates of visual field loss using standard automated perimetry (SAP) when considering different frequencies of testing using a follow-up scheme that resembles clinical practice. Observational cohort study. One thousand seventy-two eyes of 665 patients with glaucoma followed up over an average of 4.3±0.9 years. Participants with 5 or more visual field tests over a 2- to 5-year period were included to derive the longitudinal measurement variability of SAP mean deviation (MD) using linear regressions. Estimates of variability then were used to reconstruct real-world visual field data by computer simulation to evaluate the time required to detect progression for various rates of visual field loss and different frequencies of testing. The evaluation was performed using a follow-up scheme that resembled clinical practice by requiring a set of 2 baseline tests and a confirmatory test to identify progression. Time (in years) required to detect progression. The time required to detect a statistically significant negative MD slope decreased as the frequency of testing increased, albeit not proportionally. For example, 80% of eyes with an MD loss of -2 dB/year would be detected after 3.3, 2.4, and 2.1 years when testing is performed once, twice, and thrice per year, respectively. For eyes with an MD loss of -0.5 dB/year, progression can be detected with 80% power after 7.3, 5.7, and 5.0 years, respectively. This study provides information on the time required to detect progression using MD trend analysis in glaucoma eyes when different testing frequencies are used. The smaller gains in the time to detect progression when testing is increased from twice to thrice per year suggests that obtaining 2 reliable tests at baseline followed by semiannual testing and confirmation of progression through repeat testing in the initial years of follow-up may provide a good compromise for detecting progression, while minimizing the burden on health care resources in clinical practice. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. [Ciliate diversity and spatiotemporal variation in surface sediments of Yangtze River estuary hypoxic zone].

    PubMed

    Feng, Zhao; Kui-Dong, Xu; Zhao-Cui, Meng

    2012-12-01

    By using denaturing gradient gel electrophoresis (DGGE) and sequencing as well as Ludox-QPS method, an investigation was made on the ciliate diversity and its spatiotemporal variation in the surface sediments at three sites of Yangtze River estuary hypoxic zone in April and August 2011. The ANOSIM analysis indicated that the ciliate diversity had significant difference among the sites (R = 0.896, P = 0.0001), but less difference among seasons (R = 0.043, P = 0.207). The sequencing of 18S rDNA DGGE bands revealed that the most predominant groups were planktonic Choreotrichia and Oligotrichia. The detection by Ludox-QPS method showed that the species number and abundance of active ciliates were maintained at a higher level, and increased by 2-5 times in summer, as compared with those in spring. Both the Ludox-QPS method and the DGGE technique detected that the ciliate diversity at the three sites had the similar variation trend, and the Ludox-QPS method detected that there was a significant variation in the ciliate species number and abundance between different seasons. The species number detected by Ludox-QPS method was higher than that detected by DGGE bands. Our study indicated that the ciliates in Yangtze River estuary hypoxic zone had higher diversity and abundance, with the potential to supply food for the polyps of jellyfish.

  11. When Interference Helps: Increasing Executive Load to Facilitate Deception Detection in the Concealed Information Test

    PubMed Central

    Visu-Petra, George; Varga, Mihai; Miclea, Mircea; Visu-Petra, Laura

    2013-01-01

    The possibility to enhance the detection efficiency of the Concealed Information Test (CIT) by increasing executive load was investigated, using an interference design. After learning and executing a mock crime scenario, subjects underwent three deception detection tests: an RT-based CIT, an RT-based CIT plus a concurrent memory task (CITMem), and an RT-based CIT plus a concurrent set-shifting task (CITShift). The concealed information effect, consisting in increased RT and lower response accuracy for probe items compared to irrelevant items, was evidenced across all three conditions. The group analyses indicated a larger difference between RTs to probe and irrelevant items in the dual-task conditions, but this difference was not translated in a significantly increased detection efficiency at an individual level. Signal detection parameters based on the comparison with a simulated innocent group showed accurate discrimination for all conditions. Overall response accuracy on the CITMem was highest and the difference between response accuracy to probes and irrelevants was smallest in this condition. Accuracy on the concurrent tasks (Mem and Shift) was high, and responses on these tasks were significantly influenced by CIT stimulus type (probes vs. irrelevants). The findings are interpreted in relation to the cognitive load/dual-task interference literature, generating important insights for research on the involvement of executive functions in deceptive behavior. PMID:23543918

  12. Urban contribution of pharmaceuticals and other organic wastewater contaminants to streams during differing flow conditions

    USGS Publications Warehouse

    Kolpin, D.W.; Skopec, M.; Meyer, M.T.; Furlong, E.T.; Zaugg, S.D.

    2004-01-01

    During 2001, 76 water samples were collected upstream and downstream of select towns and cities in Iowa during high-, normal- and low-flow conditions to determine the contribution of urban centers to concentrations of pharmaceuticals and other organic wastewater contaminants (OWCs) in streams under varying flow conditions. The towns ranged in population from approximately 2000 to 200 000. Overall, one or more OWCs were detected in 98.7% of the samples collected, with 62 of the 105 compounds being found. The most frequently detected compounds were metolachlor (pesticide), cholesterol (plant and animal sterol), caffeine (stimulant), β-sitosterol (plant sterol) and 1,7-dimethylxanthine (caffeine degradate). The number of OWCs detected decreased as streamflow increased from low- (51 compounds detected) to normal- (28) to high-flow (24) conditions. Antibiotics and other prescription drugs were only frequently detected during low-flow conditions. During low-flow conditions, 15 compounds (out of the 23) and ten compound groups (out of 11) detected in more than 10% of the streams sampled had significantly greater concentrations in samples collected downstream than in those collected upstream of the urban centers. Conversely, no significant differences in the concentrations were found during high-flow conditions. Thus, the urban contribution of OWCs to streams became progressively muted as streamflow increased.

  13. The effect of length and starting year on trend analyses of temperatures in Spanish mainland (1951-2010). Seasonal analysis: Winter (II)

    NASA Astrophysics Data System (ADS)

    Salinas Solé, Celia; Peña Angulo, Dhais; Gonzalez Hidalgo, Jose Carlos; Brunetti, Michele

    2017-04-01

    In this poster we applied the moving window approach (see Poster I of this collection) to analyze trends of winter and its corresponding months (December, January, February) temperature mean values of maximum (Tmax) and minimum (Tmin) in Spanish mainland to detect the effects of length period and starting year. Monthly series belong to Monthly Temperature dataset of Spanish mainland (MOTEDAS). Database contains in its grid format of 5236 pixels of monthly series (10x10 km). The threshold used in spatial analyses considers 20% of land under significant trend (p<0.05). The most striking results are as follow: • Seasonal trend analyses of Tmax shows that global trend 1951-2010 was positive and significant mostly in central-western areas; from 1970 to 2010 there is less than 20% of land with significant trend. In the case of Tmin no relevant significant period is detected. • Monthly Tmax analyses show that December significant trend changed from positive (>20%) in between 1955-2010 until 1962-2010, to negative from 1976-2010. Meanwhile January does not show relevant period with significant trend; finally Tmax in February shows different periods with positive significant trend (>20% of land) 1951-2010 to 1954-2010 and 1962-2010 to 1968-2010. No significant trend is detected after this data. • Monthly Tmin trend analyses show that except exceptional period, no months present any significant trend. As conclusions, we have detected that for winter and winter-months, Tmax trends are not significant from 1970 across Spanish mainland. In the case of Tmin we conclude that no significant trend have been occurred in any temporal windows analyzed. Results differ from what traditionally has been assumed that the increase of the average annual temperature was due to the increase of trends in the winter season. And these analyses also show that seasonal trend values could hide monthly behavior. So extreme caution should be taken into account when seasonal values are offered.

  14. Expression of Caspase-1 in breast cancer tissues and its effects on cell proliferation, apoptosis and invasion.

    PubMed

    Sun, Yanxia; Guo, Yingzhen

    2018-05-01

    The present study aimed to detect the expression of Caspase-1 in the tumor tissues and tumor-adjacent tissues of patients with breast cancer, and to investigate the effects of Caspase-1 on the proliferation, apoptosis and invasion of breast cancer cells. Reverse transcription-quantitative polymerase chain reaction was used to detect Caspase-1 mRNA expression in breast cancer tissues and tumor-adjacent tissues from patients. Additionally, the human breast cancer MDA-MB-231 cell line was treated with the Caspase-1 small molecule inhibitor Ac-YVAD-CMK, following which the changes to Caspase-1 protein expression were detected via western blotting. The MTT method detected the changes to cell proliferation, flow cytometry detected the rate of apoptosis, and a Transwell assay was employed to assess invasion. Caspase-1 mRNA expression was significantly decreased in the breast cancer tissues of patients, compared with in the tumor-adjacent tissues, a difference that was statistically significant (P<0.05). Treatment with the Ac-YVAD-CMK markedly decreased the protein expression of Caspase-1 in MDA-MB-231 cells, and the difference was statistically significant (P<0.05). Following this treatment of Ac-YVAD-CMK cells, the proliferation and invasion abilities markedly increased, while the apoptotic levels significantly decreased (P<0.05). In conclusion, the expression of Caspase-1 is low in breast cancer tissues, which may promote the proliferation and invasion of breast cancer cells and could be closely associated with the occurrence and development of breast cancer.

  15. Sister chromatid exchanges and micronuclei analysis in lymphocytes of men exposed to simazine through drinking water.

    PubMed

    Suárez, Susanna; Rubio, Arantxa; Sueiro, Rosa Ana; Garrido, Joaquín

    2003-06-06

    In some cities of the autonomous community of Extremadura (south-west of Spain), levels of simazine from 10 to 30 ppm were detected in tap water. To analyse the possible effect of this herbicide, two biomarkers, sister chromatid exchanges (SCE) and micronuclei (MN), were used in peripheral blood lymphocytes from males exposed to simazine through drinking water. SCE and MN analysis failed to detect any statistically significant increase in the people exposed to simazine when compared with the controls. With respect to high frequency cells (HFC), a statistically significant difference was detected between exposed and control groups.

  16. Infrared polarimetric sensing of oil on water

    NASA Astrophysics Data System (ADS)

    Chenault, David B.; Vaden, Justin P.; Mitchell, Douglas A.; DeMicco, Erik D.

    2016-10-01

    Infrared polarimetry is an emerging sensing modality that offers the potential for significantly enhanced contrast in situations where conventional thermal imaging falls short. Polarimetric imagery leverages the different polarization signatures that result from material differences, surface roughness quality, and geometry that are frequently different from those features that lead to thermal signatures. Imaging of the polarization in a scene can lead to enhanced understanding, particularly when materials in a scene are at thermal equilibrium. Polaris Sensor Technologies has measured the polarization signatures of oil on water in a number of different scenarios and has shown significant improvement in detection through the contrast improvement offered by polarimetry. The sensing improvement offers the promise of automated detection of oil spills and leaks for routine monitoring and accidents with the added benefit of being able to continue monitoring at night. In this paper, we describe the instrumentation, and the results of several measurement exercises in both controlled and uncontrolled conditions.

  17. TREFEX: Trend Estimation and Change Detection in the Response of MOX Gas Sensors

    PubMed Central

    Pashami, Sepideh; Lilienthal, Achim J.; Schaffernicht, Erik; Trincavelli, Marco

    2013-01-01

    Many applications of metal oxide gas sensors can benefit from reliable algorithms to detect significant changes in the sensor response. Significant changes indicate a change in the emission modality of a distant gas source and occur due to a sudden change of concentration or exposure to a different compound. As a consequence of turbulent gas transport and the relatively slow response and recovery times of metal oxide sensors, their response in open sampling configuration exhibits strong fluctuations that interfere with the changes of interest. In this paper we introduce TREFEX, a novel change point detection algorithm, especially designed for metal oxide gas sensors in an open sampling system. TREFEX models the response of MOX sensors as a piecewise exponential signal and considers the junctions between consecutive exponentials as change points. We formulate non-linear trend filtering and change point detection as a parameter-free convex optimization problem for single sensors and sensor arrays. We evaluate the performance of the TREFEX algorithm experimentally for different metal oxide sensors and several gas emission profiles. A comparison with the previously proposed GLR method shows a clearly superior performance of the TREFEX algorithm both in detection performance and in estimating the change time. PMID:23736853

  18. Low contrast detection in abdominal CT: comparing single-slice and multi-slice tasks

    NASA Astrophysics Data System (ADS)

    Ba, Alexandre; Racine, Damien; Viry, Anaïs.; Verdun, Francis R.; Schmidt, Sabine; Bochud, François O.

    2017-03-01

    Image quality assessment is crucial for the optimization of computed tomography (CT) protocols. Human and mathematical model observers are increasingly used for the detection of low contrast signal in abdominal CT, but are frequently limited to the use of a single image slice. Another limitation is that most of them only consider the detection of a signal embedded in a uniform background phantom. The purpose of this paper was to test if human observer performance is significantly different in CT images read in single or multiple slice modes and if these differences are the same for anatomical and uniform clinical images. We investigated detection performance and scrolling trends of human observers of a simulated liver lesion embedded in anatomical and uniform CT backgrounds. Results show that observers don't take significantly benefit of additional information provided in multi-slice reading mode. Regarding the background, performances are moderately higher for uniform than for anatomical images. Our results suggest that for low contrast detection in abdominal CT, the use of multi-slice model observers would probably only add a marginal benefit. On the other hand, the quality of a CT image is more accurately estimated with clinical anatomical backgrounds.

  19. Malingering and PTSD: detecting malingering and war related PTSD by Miller Forensic Assessment of Symptoms Test (M-FAST).

    PubMed

    Ahmadi, Khodabakhsh; Lashani, Zeynab; Afzali, Mohammad Hassan; Tavalaie, S Abbas; Mirzaee, Jafar

    2013-05-29

    Malingering is prevalent in PTSD, especially in delayed-onset PTSD. Despite the attempts to detect it, indicators, tools and methods to accurately detect malingering need extensive scientific and clinical research. Therefore, this study was designed to validate a tool that can detect malingering of war-related PTSD by Miller Forensic Assessment of Symptoms Test (M-FAST). In this blind clinical diagnosis study, one hundred and twenty veterans referred to War Related PTSD Diagnosis Committee in Iran in 2011 were enrolled. In the first step, the clients received Psychiatry diagnosis and were divided into two groups based on the DSM-IV-TR, and in the second step, the participants completed M-FAST. The t-test score within two groups by M-FAST Scale showed a significant difference (t = 14.058, P < 0.0001), and 92% of malingering war-related PTSD participants scored more than 6 and %87 of PTSD group scored less than 6 in M-FAST Scale. M-FAST showed a significant difference between war-related PTSD and malingering participants. The ≥6 score cutoff was suggested by M-FAST to detect malingering of war-related PTSD.

  20. [The clinical value of sentinel lymph node detection in laryngeal and hypopharyngeal carcinoma patients with clinically negative neck by methylene blue method and radiolabeled tracer method].

    PubMed

    Zhao, Xin; Xiao, Dajiang; Ni, Jianming; Zhu, Guochen; Yuan, Yuan; Xu, Ting; Zhang, Yongsheng

    2014-11-01

    To investigate the clinical value of sentinel lymph node (SLN) detection in laryngeal and hypopharyngeal carcinoma patients with clinically negative neck (cN0) by methylene blue method, radiolabeled tracer method and combination of these two methods. Thirty-three patients with cN0 laryngeal carcinoma and six patients with cN0 hypopharyngeal carcinoma underwent SLN detection using both of methylene blue and radiolabeled tracer method. All these patients were accepted received the injection of radioactive isotope 99 Tc(m)-sulfur colloid (SC) and methylene blue into the carcinoma before surgery, then all these patients underwent intraopertive lymphatic mapping with a handheld gamma-detecting probe and blue-dyed SLN. After the mapping of SLN, selected neck dissections and tumor resections were peformed. The results of SLN detection by radiolabeled tracer, dye and combination of both methods were compared. The detection rate of SLN by radiolabeled tracer, methylene blue and combined method were 89.7%, 79.5%, 92.3% respectively. The number of detected SLN was significantly different between radiolabeled tracer method and combined method, and also between methylene blue method and combined method. The detection rate of methylene blue and radiolabeled tracer method were significantly different from combined method (P < 0.05). Nine patients were found to have lymph node metastasis by final pathological examination. The accuracy and negative rate of SLN detection of the combined method were 97.2% and 11.1%. The combined method using radiolabeled tracer and methylene blue can improve the detection rate and accuracy of sentinel lymph node detection. Furthermore, sentinel lymph node detection can accurately represent the cervical lymph node status in cN0 laryngeal and hypopharyngeal carcinoma.

  1. Neural correlates of binaural masking level difference in the inferior colliculus of the barn owl (Tyto alba).

    PubMed

    Asadollahi, Ali; Endler, Frank; Nelken, Israel; Wagner, Hermann

    2010-08-01

    Humans and animals are able to detect signals in noisy environments. Detection improves when the noise and the signal have different interaural phase relationships. The resulting improvement in detection threshold is called the binaural masking level difference. We investigated neural mechanisms underlying the release from masking in the inferior colliculus of barn owls in low-frequency and high-frequency neurons. A tone (signal) was presented either with the same interaural time difference as the noise (masker) or at a 180 degrees phase shift as compared with the interaural time difference of the noise. The changes in firing rates induced by the addition of a signal of increasing level while masker level was kept constant was well predicted by the relative responses to the masker and signal alone. In many cases, the response at the highest signal levels was dominated by the response to the signal alone, in spite of a significant response to the masker at low signal levels, suggesting the presence of occlusion. Detection thresholds and binaural masking level differences were widely distributed. The amount of release from masking increased with increasing masker level. Narrowly tuned neurons in the central nucleus of the inferior colliculus had detection thresholds that were lower than or similar to those of broadly tuned neurons in the external nucleus of the inferior colliculus. Broadly tuned neurons exhibited higher masking level differences than narrowband neurons. These data suggest that detection has different spectral requirements from localization.

  2. Screening and cervical cancer cure: population based cohort study

    PubMed Central

    Andersson, Therese M-L; Lambert, Paul C; Kemetli, Levent; Silfverdal, Lena; Strander, Björn; Ryd, Walter; Dillner, Joakim; Törnberg, Sven; Sparén, Pär

    2012-01-01

    Objective To determine whether detection of invasive cervical cancer by screening results in better prognosis or merely increases the lead time until death. Design Nationwide population based cohort study. Setting Sweden. Participants All 1230 women with cervical cancer diagnosed during 1999-2001 in Sweden prospectively followed up for an average of 8.5 years. Main outcome measures Cure proportions and five year relative survival ratios, stratified by screening history, mode of detection, age, histopathological type, and FIGO (International Federation of Gynecology and Obstetrics) stage. Results In the screening ages, the cure proportion for women with screen detected invasive cancer was 92% (95% confidence interval 75% to 98%) and for symptomatic women was 66% (62% to 70%), a statistically significant difference in cure of 26% (16% to 36%). Among symptomatic women, the cure proportion was significantly higher for those who had been screened according to recommendations (interval cancers) than among those overdue for screening: difference in cure 14% (95% confidence interval 6% to 23%). Cure proportions were similar for all histopathological types except small cell carcinomas and were closely related to FIGO stage. A significantly higher cure proportion for screen detected cancers remained after adjustment for stage at diagnosis (difference 15%, 7% to 22%). Conclusions Screening is associated with improved cure of cervical cancer. Confounding cannot be ruled out, but the effect was not attributable to lead time bias and was larger than what is reflected by down-staging. Evaluations of screening programmes should consider the assessment of cure proportions. PMID:22381677

  3. Screening and cervical cancer cure: population based cohort study.

    PubMed

    Andrae, Bengt; Andersson, Therese M-L; Lambert, Paul C; Kemetli, Levent; Silfverdal, Lena; Strander, Björn; Ryd, Walter; Dillner, Joakim; Törnberg, Sven; Sparén, Pär

    2012-03-01

    To determine whether detection of invasive cervical cancer by screening results in better prognosis or merely increases the lead time until death. Nationwide population based cohort study. Sweden. All 1230 women with cervical cancer diagnosed during 1999-2001 in Sweden prospectively followed up for an average of 8.5 years. Cure proportions and five year relative survival ratios, stratified by screening history, mode of detection, age, histopathological type, and FIGO (International Federation of Gynecology and Obstetrics) stage. In the screening ages, the cure proportion for women with screen detected invasive cancer was 92% (95% confidence interval 75% to 98%) and for symptomatic women was 66% (62% to 70%), a statistically significant difference in cure of 26% (16% to 36%). Among symptomatic women, the cure proportion was significantly higher for those who had been screened according to recommendations (interval cancers) than among those overdue for screening: difference in cure 14% (95% confidence interval 6% to 23%). Cure proportions were similar for all histopathological types except small cell carcinomas and were closely related to FIGO stage. A significantly higher cure proportion for screen detected cancers remained after adjustment for stage at diagnosis (difference 15%, 7% to 22%). Screening is associated with improved cure of cervical cancer. Confounding cannot be ruled out, but the effect was not attributable to lead time bias and was larger than what is reflected by down-staging. Evaluations of screening programmes should consider the assessment of cure proportions.

  4. Evaluation of fluorescence in situ hybridization techniques to study long non-coding RNA expression in cultured cells

    PubMed Central

    Soares, Ricardo J; Maglieri, Giulia; Gutschner, Tony; Lund, Anders H; Nielsen, Boye S

    2018-01-01

    Abstract Deciphering the functions of long non-coding RNAs (lncRNAs) is facilitated by visualization of their subcellular localization using in situ hybridization (ISH) techniques. We evaluated four different ISH methods for detection of MALAT1 and CYTOR in cultured cells: a multiple probe detection approach with or without enzymatic signal amplification, a branched-DNA (bDNA) probe and an LNA-modified probe with enzymatic signal amplification. All four methods adequately stained MALAT1 in the nucleus in all of three cell lines investigated, HeLa, NHDF and T47D, and three of the methods detected the less expressed CYTOR. The sensitivity of the four ISH methods was evaluated by image analysis. In all three cell lines, the two methods involving enzymatic amplification gave the most intense MALAT1 signal, but the signal-to-background ratios were not different. CYTOR was best detected using the bDNA method. All four ISH methods showed significantly reduced MALAT1 signal in knock-out cells, and siRNA-induced knock-down of CYTOR resulted in significantly reduced CYTOR ISH signal, indicating good specificity of the probe designs and detection systems. Our data suggest that the ISH methods allow detection of both abundant and less abundantly expressed lncRNAs, although the latter required the use of the most specific and sensitive probe detection system. PMID:29059327

  5. Bayesian longitudinal segmentation of hippocampal substructures in brain MRI using subject-specific atlases

    PubMed Central

    Iglesias, Juan Eugenio; Van Leemput, Koen; Augustinack, Jean; Insausti, Ricardo; Fischl, Bruce; Reuter, Martin

    2016-01-01

    The hippocampal formation is a complex, heterogeneous structure that consists of a number of distinct, interacting subregions. Atrophy of these subregions is implied in a variety of neurodegenerative diseases, most prominently in Alzheimer’s disease (AD). Thanks to the increasing resolution of MR images and computational atlases, automatic segmentation of hippocampal subregions is becoming feasible in MRI scans. Here we introduce a generative model for dedicated longitudinal segmentation that relies on subject-specific atlases. The segmentations of the scans at the different time points are jointly computed using Bayesian inference. All time points are treated the same to avoid processing bias. We evaluate this approach using over 4,700 scans from two publicly available datasets (ADNI and MIRIAD). In test-retest reliability experiments, the proposed method yielded significantly lower volume differences and significantly higher Dice overlaps than the cross-sectional approach for nearly every subregion (average across subregions: 4.5% vs. 6.5%, Dice overlap: 81.8% vs. 75.4%). The longitudinal algorithm also demonstrated increased sensitivity to group differences: in MIRIAD (69 subjects: 46 with AD and 23 controls), it found differences in atrophy rates between AD and controls that the cross sectional method could not detect in a number of subregions: right parasubiculum, left and right presubiculum, right subiculum, left dentate gyrus, left CA4, left HATA and right tail. In ADNI (836 subjects: 369 with AD, 215 with early cognitive impairment – eMCI – and 252 controls), all methods found significant differences between AD and controls, but the proposed longitudinal algorithm detected differences between controls and eMCI and differences between eMCI and AD that the cross sectional method could not find: left presubiculum, right subiculum, left and right parasubiculum, left and right HATA. Moreover, many of the differences that the cross-sectional method already found were detected with higher significance. The presented algorithm will be made available as part of the open-source neuroimaging package FreeSurfer. PMID:27426838

  6. Statistical comparison of pooled nitrogen washout data of various altitude decompression response groups

    NASA Technical Reports Server (NTRS)

    Edwards, B. F.; Waligora, J. M.; Horrigan, D. J., Jr.

    1985-01-01

    This analysis was done to determine whether various decompression response groups could be characterized by the pooled nitrogen (N2) washout profiles of the group members, pooling individual washout profiles provided a smooth time dependent function of means representative of the decompression response group. No statistically significant differences were detected. The statistical comparisons of the profiles were performed by means of univariate weighted t-test at each 5 minute profile point, and with levels of significance of 5 and 10 percent. The estimated powers of the tests (i.e., probabilities) to detect the observed differences in the pooled profiles were of the order of 8 to 30 percent.

  7. Salmonella rarely detected in Mississippi coastal waters and sediment.

    PubMed

    Carr, M R; Wang, S Y; McLean, T I; Flood, C J; Ellender, R D

    2010-12-01

    Standards for the rapid detection of individual pathogens from environmental samples have not been developed, but in their absence, the use of molecular-based detection methods coupled with traditional microbiology techniques allows for rapid and accurate pathogen detection from environmental waters and sediment. The aim of this research was to combine the use of enrichment with PCR for detection of Salmonella in Mississippi coastal waters and sediment and observe if that presence correlated with levels of enterococci and climatological variables. Salmonella were primarily found in samples that underwent nutrient enrichment and were present more frequently in freshwater than marine waters. Salmonella were detected infrequently in marine and freshwater sediments. There was a significant positive correlation between the presence of detectable Salmonella and the average enterococcal count. An inverse relationship, however, was observed between the frequency of detection and the levels of salinity, turbidity and sunlight exposure. Results from this study indicated the presence of Salmonella in Mississippi coastal waters, and sediments are very low with significant differences between freshwater and marine environments. Using pathogenic and novel nonpathogenic molecular markers, Salmonella do not appear to be a significant pathogenic genus along the Mississippi Coast. © 2010 The Authors. Journal of Applied Microbiology © 2010 The Society for Applied Microbiology.

  8. Comparison of formant detection methods used in speech processing applications

    NASA Astrophysics Data System (ADS)

    Belean, Bogdan

    2013-11-01

    The paper describes time frequency representations of speech signal together with the formant significance in speech processing applications. Speech formants can be used in emotion recognition, sex discrimination or diagnosing different neurological diseases. Taking into account the various applications of formant detection in speech signal, two methods for detecting formants are presented. First, the poles resulted after a complex analysis of LPC coefficients are used for formants detection. The second approach uses the Kalman filter for formant prediction along the speech signal. Results are presented for both approaches on real life speech spectrograms. A comparison regarding the features of the proposed methods is also performed, in order to establish which method is more suitable in case of different speech processing applications.

  9. [Detection and Analysis of Human Parainfluenza Virus Infection in Hospitalized Adults with Acute Respiratory Tract Infections].

    PubMed

    Li, Xing-Qiao; Liu, Xue-Wei; Zhou, Tao; Pei, Xiao-Fang

    2017-11-01

    To investigate the prevalence and gene characteristics of different groups of human parainfluenza virus (HPIV) infection in hospitalized adults with acute respiratory tract infections (ARI). RT-PCR was used to detect HPIV hemagglutinin (HA) DNA,which was extracted from sputum samples of 1 039 adult patients with ARI from March,2014 to June,2016. The HA gene amplified from randomly selected positive samples were sequenced to analyze the homology and variation. 10.6% (110/1 039) of these samples were positive for HPIV,including 8 cases of HPIV-1,22 cases of HPIV-2,46 cases of HPIV-3 and 34 cases of HPIV-4. Detectable rate varied among different groups of HPIV according to seasons of the year and ages of patients. No significant differences were found between the positive samples and the reference sequences. Compared with different reference strains of different regions,the genetic distance of nucleotide is the smallest between the strains tested in this study and the reference strains of other provinces and cities in China. In Chengdu region,HPIV virus is highly detected in ARI,all subtypes were detected with HPIV-3 being the main subtype.

  10. Effect of background parenchymal enhancement on breast cancer detection with magnetic resonance imaging.

    PubMed

    Telegrafo, M; Rella, L; Stabile Ianora, A A; Angelelli, G; Moschetta, M

    2016-03-01

    To investigate whether background parenchymal enhancement (BPE) may influence the sensitivity of dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging in breast cancer detection. A total of 180 consecutive women with 194 breast cancers underwent MR imaging examination. Women were assigned to two different groups depending on the degree of BPE. Group 1 consisted of women with minimal or mild BPE and group 2 of women with moderate or marked BPE. The distributions of histotypes of tumors within the two groups were compared using the χ(2) test. Difference in sensitivities of DCE-MR imaging for tumor detection between the two groups was searched for using the Student t-test. No differences in terms of distributions of histotypes of tumors between the two groups of women were found (P=0.5). The 11% difference in sensitivity of DCE-MR imaging for tumor detection between group 1 (91/92; 99%; 95% CI: 94-100%) and group 2 (90/102; 88%; 95% CI: 80-94%) was statistically significant (P=0.0058). The sensitivity of DCE-MR imaging is significantly lower in women with moderate and marked BPE as compared with women with minimal and mild BPE regardless of cancer histotype. BPE could represent a limitation for breast MR imaging interpretation and should be indicated in MR imaging reports. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. Comparison of methanol and isopropanol as wash solvents for determination of hair cortisol concentration in grizzly bears and polar bears.

    PubMed

    Kroshko, Thomas; Kapronczai, Luciene; Cattet, Marc R L; Macbeth, Bryan J; Stenhouse, Gordon B; Obbard, Martyn E; Janz, David M

    2017-01-01

    Methodological differences among laboratories are recognized as significant sources of variation in quantification of hair cortisol concentration (HCC). An important step in processing hair, particularly when collected from wildlife, is the choice of solvent used to remove or "wash" external hair shaft cortisol prior to quantification of HCC. The present study systematically compared methanol and isopropanol as wash solvents for their efficiency at removing external cortisol without extracting internal hair shaft cortisol in samples collected from free-ranging grizzly bears and polar bears. Cortisol concentrations in solvents and hair were determined in each of one to eight washes of hair with each solvent independently. •There were no significant decreases in internal hair shaft cortisol among all eight washes for either solvent, although methanol removed detectable hair surface cortisol after one wash in grizzly bear hair whereas hair surface cortisol was detected in all eight isopropanol washes.•There were no significant differences in polar bear HCC washed one to eight times with either solvent, but grizzly bear HCC was significantly greater in hair washed with isopropanol compared to methanol.•There were significant differences in HCC quantified using different commercial ELISA kits commonly used for HCC determinations.

  12. [Effects of different salt and alkali stresses on ion distribution in Red globe/Beta grapevines].

    PubMed

    Du, Yuan-peng; Jin, Xue-juan; Guo, Shu-hua; Fu, Qing-qing; Zhai, Heng

    2015-06-01

    The potted Red globe/Beta grapevines were selected to irrigated with NaCl, Na2SO4, NaHCO3, NH4Cl, (NH4)2SO4. Hence, the ions which induced leaf etiolation were screened and the impacts of different salt and alkali on ion distribution in different organs of grapevines were investigated. It was found that NaHCO3 exerted the greatest effects on grapevines, leaf etiolation at 14 days after treatment. By contrast, NaCl and NH4Cl treatments induced leaf etiolation at 28 days after treatment. The Na+ content in all the detected organs were significantly increased under NaHCO3 and NaCl treatment, and Na+ content in root under NaHCO3 treatment was 6.4 times as that in control root. NaHCO3 and NaCl treatments significantly decreased K+ content in the organs with the exception of leaf. NaHCO3 treatment significantly decreased K/Na in different organs, which declined to 0.1 in root. By contrast, NaCl treatment significantly decreased K/Na in the detected organs with exception of stem. Besides, the transport of Ca2+, Mg2+, Fe2+ to aboveground organs was significantly decreased by NaHCO3 and NaCl treatments. K/Na ratio in the detected organs were decreased under NH4Cl, (NH4) 2SO4 and Na2SO4 treatments, especially under NH4 Cl treatment. Taken together, NaHCO3 was the primary factor resulting in leaf etiolation, followed by NaCl and NH4Cl, while (NH4) 2SO4 and Na2SO4 produced impacts.

  13. Shape detection of Gaborized outline versions of everyday objects

    PubMed Central

    Sassi, Michaël; Machilsen, Bart; Wagemans, Johan

    2012-01-01

    We previously tested the identifiability of six versions of Gaborized outlines of everyday objects, differing in the orientations assigned to elements inside and outside the outline. We found significant differences in identifiability between the versions, and related a number of stimulus metrics to identifiability [Sassi, M., Vancleef, K., Machilsen, B., Panis, S., & Wagemans, J. (2010). Identification of everyday objects on the basis of Gaborized outline versions. i-Perception, 1(3), 121–142]. In this study, after retesting the identifiability of new variants of three of the stimulus versions, we tested their robustness to local orientation jitter in a detection experiment. In general, our results replicated the key findings from the previous study, and allowed us to substantiate our earlier interpretations of the effects of our stimulus metrics and of the performance differences between the different stimulus versions. The results of the detection task revealed a different ranking order of stimulus versions than the identification task. By examining the parallels and differences between the effects of our stimulus metrics in the two tasks, we found evidence for a trade-off between shape detectability and identifiability. The generally simple and smooth shapes that yield the strongest contour integration and most robust detectability tend to lack the distinguishing features necessary for clear-cut identification. Conversely, contours that do contain such identifying features tend to be inherently more complex and, therefore, yield weaker integration and less robust detectability. PMID:23483752

  14. [Establishment of animal model for Pneumocystis carinii and study on etiological and molecular biological detection technology].

    PubMed

    Tian, Li-guang; Ai, Lin; Chu, Yan-hong; Wu, Xiu-ping; Cai, Yu-chun; Chen, Zhuo; Chen, Shao-hong; Chen, Jia-xu

    2015-04-01

    To establish an animal model for Pneumocystis pneumonia (PCP) and to study the etiological and molecular biological technology for PCP detection. SD and Wistar rats were divided into experimental and control groups randomly. The animals in the experimental group were immunosuppressed by subcutaneous injection with dexamethasone 2 mg per time per rat, twice a week, while those in the control group underwent the same way of injection with physiological saline simultaneously. After the induction for 8 weeks, all the rats were killed and their bronchoalveolar lavage fluid (BALF) and lung tissues were collected for smear making and microscopic detection. Meanwhile, the BALF samples were detected by PCR, and the products were sequenced and compared with rat source PCP in GenBank. A total of 34 samples of lung tissue and BALF were observed. The etiological detection showed that the infection rates of the rats in the experimental and control groups were 29.2% (7/24) and 0, respectively. In the experimental group, the infection rates of SD and Wistar rats were 25.0% (3/12) and 33.3% (4/12), respectively, and the difference between them was not statistically significant (P = 0.31). The positive detection rates of the lung smears and BALF from SD rats in the experimental group were 25.0% (3/12) and 16.7% (2/12), respectively, while those in Wistar rats in the experimental group were 33.3% (4/12) and 16.7% (2/12), respectively, and there were no statistically significant difference between them (P = 0.34, 0.24). A total of 28 samples of BALF were detected by PCR, and the positive detection rates of rats in the experimental group and control group were 91.7% (26/28) and 0, respectively. The sequence analysis of the PCR products showed that it shared 100% homology with the genes of rat source PCP in Gen Bank (JX499145, GU133622 and EF646865). The animal model of PCP can be established by subcutaneous injection with dexamethasone. As animal models, there are no significant difference between SD rats and Wistar rats. PCR method is suitable for PCP detection at the early stage of infection, while etiological detection with high missing rate is not a right option.

  15. Exploring the capabilities of support vector machines in detecting silent data corruptions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subasi, Omer; Di, Sheng; Bautista-Gomez, Leonardo

    As the exascale era approaches, the increasing capacity of high-performance computing (HPC) systems with targeted power and energy budget goals introduces significant challenges in reliability. Silent data corruptions (SDCs), or silent errors, are one of the major sources that corrupt the execution results of HPC applications without being detected. Here in this paper, we explore a set of novel SDC detectors – by leveraging epsilon-insensitive support vector machine regression – to detect SDCs that occur in HPC applications. The key contributions are threefold. (1) Our exploration takes temporal, spatial, and spatiotemporal features into account and analyzes different detectors based onmore » different features. (2) We provide an in-depth study on the detection ability and performance with different parameters, and we optimize the detection range carefully. (3) Experiments with eight real-world HPC applications show that support-vector-machine-based detectors can achieve detection sensitivity (i.e., recall) up to 99% yet suffer a less than 1% false positive rate for most cases. Our detectors incur low performance overhead, 5% on average, for all benchmarks studied in this work.« less

  16. Exploring the capabilities of support vector machines in detecting silent data corruptions

    DOE PAGES

    Subasi, Omer; Di, Sheng; Bautista-Gomez, Leonardo; ...

    2018-02-01

    As the exascale era approaches, the increasing capacity of high-performance computing (HPC) systems with targeted power and energy budget goals introduces significant challenges in reliability. Silent data corruptions (SDCs), or silent errors, are one of the major sources that corrupt the execution results of HPC applications without being detected. Here in this paper, we explore a set of novel SDC detectors – by leveraging epsilon-insensitive support vector machine regression – to detect SDCs that occur in HPC applications. The key contributions are threefold. (1) Our exploration takes temporal, spatial, and spatiotemporal features into account and analyzes different detectors based onmore » different features. (2) We provide an in-depth study on the detection ability and performance with different parameters, and we optimize the detection range carefully. (3) Experiments with eight real-world HPC applications show that support-vector-machine-based detectors can achieve detection sensitivity (i.e., recall) up to 99% yet suffer a less than 1% false positive rate for most cases. Our detectors incur low performance overhead, 5% on average, for all benchmarks studied in this work.« less

  17. A generalised significance test for individual communities in networks.

    PubMed

    Kojaku, Sadamori; Masuda, Naoki

    2018-05-09

    Many empirical networks have community structure, in which nodes are densely interconnected within each community (i.e., a group of nodes) and sparsely across different communities. Like other local and meso-scale structure of networks, communities are generally heterogeneous in various aspects such as the size, density of edges, connectivity to other communities and significance. In the present study, we propose a method to statistically test the significance of individual communities in a given network. Compared to the previous methods, the present algorithm is unique in that it accepts different community-detection algorithms and the corresponding quality function for single communities. The present method requires that a quality of each community can be quantified and that community detection is performed as optimisation of such a quality function summed over the communities. Various community detection algorithms including modularity maximisation and graph partitioning meet this criterion. Our method estimates a distribution of the quality function for randomised networks to calculate a likelihood of each community in the given network. We illustrate our algorithm by synthetic and empirical networks.

  18. Prevalence of hand osteoarthritis and knee osteoarthritis in Kashin-Beck disease endemic areas and non Kashin-Beck disease endemic areas: A status survey

    PubMed Central

    Song, QuanQuan; Liu, Yun Qi; Sun, Li Yan; Deng, Qing; Wang, Shao Ping; Cao, Yan Hong; Zhang, Xue Ying; Jiang, Yuan Yuan; Lv, Hong Yan; Duan, Li Bin; Yu, Jun

    2018-01-01

    Osteoarthritis (OA) is a considerable health problem worldwide, and the prevalence of OA varies in different regions. In this study, the prevalence of OA in Kashin-Beck disease (KBD) and non-KBD endemic areas was examined, respectively. According to monitoring data, 4 types of regions (including none, mild, moderate and high KBD endemic areas) in Heilongjiang and Jilin provinces were selected. All local residents were eligible for inclusion criteria have undergone X-ray images of hands and anteroposterior image of knees. A total of 1673 cases were collected, 1446 cases were analyzed after removing the KBD patients (227). The overall hand OA and knee OA detection rates were 33.3% (481/1446) and 56.6% (818/1446), respectively. After being standardized by age, the detection rate of hand OA in the KBD endemic areas was significantly higher than that in the non-endemic endemic areas. Differently, there was no significant difference in the detection rates of knee OA between the KBD endemic areas and the non-endemic area. The correlation coefficient between the severity of OA and the severity of knee OA was 0.358 and 0.197 in the KBD and non-KBD endemic areas, respectively. Where the KBD historical prevalence level was higher, the severity of the residents’ hand OA was more serious. The detection rates of hand OA and knee OA increased with age. The detection rate of knee OA increased with the increase in body mass index. The prevalence of hand OA was closely related to the pathogenic factors of Kashin-Beck disease, and the prevalence of knee OA had no significant correlation with KBD pathogenic factors. PMID:29320581

  19. Spectrophotometric photodynamic detection involving extracorporeal treatment with hexaminolevulinate for bladder cancer cells in voided urine.

    PubMed

    Nakai, Yasushi; Ozawa, Toshiyuki; Mizuno, Fumiko; Onishi, Sayuri; Owari, Takuya; Hori, Syunta; Morizawa, Yosuke; Tatsumi, Yosihiro; Miyake, Makito; Tanaka, Nobumichi; Tsuruta, Daisuke; Fujimoto, Kiyohide

    2017-11-01

    To evaluate the feasibility of hexaminolevulinate (HAL) for the photodynamic detection of cancer cells in voided urine. This study included 50 patients with bladder cancer that was confirmed histologically after transurethral resection (bladder cancer group) and 50 outpatients without a history of urothelial carcinoma or cancer-related findings (no malignancy group). One third of the voided urine samples were incubated with aminolevulinic acid (ALA-treated samples), one third were incubated with HAL (HAL-treated samples), and the remaining samples were incubated without treatment (untreated samples). For detecting cellular protoporphyrin IX levels, the intensity of the samples at the excitation wavelength of 405 nm was measured using a spectrophotometer. The difference between the intensity of the ALA-treated or HAL-treated samples and the untreated samples at 635 nm was calculated. HAL-induced fluorescence cytology (HFC) showed that the difference was significantly higher in patients with high-grade tumors than in those with low-grade tumors (p = 0.0003) and the difference was significantly higher in patients with low-grade tumors than in those without a history of urothelial carcinoma or cancer-related findings (p = 0.021). The areas under the receiver operating characteristic curves of ALA-induced fluorescence cytology (AFC) and HFC were 0.77 and 0.81, respectively. The AUC of HFC was significantly higher than that of AFC (p < 0.0001). The overall sensitivity values for conventional cytology, AFC, and HFC were 49, 74, and 74%, respectively. The overall specificity values for AFC and HFC were 70 and 94%, respectively. Spectrophotometric photodynamic detection involving extracorporeal treatment with HAL for bladder cancer cells in voided urine showed high accuracy. This bladder cancer detection method is easy and cost-effective, and has the potential for clinical use.

  20. [Sub-health status of middle school teachers and its correlation analysis with occupational stress].

    PubMed

    Chang, W J; Shao, H M; Zhi, X Y; Xu, J; Xie, J

    2017-08-20

    Objective: To study the distribution of sub-health and occupational stress as well as their correlation among middle school teachers in Tianjin, then provide evidences for prevention and control of the status of sub-health. Methods: A total of 3 522 middle school teachers from six districts of Tianjin were recruited with stratified cluster sampling strategy for the investigation of Sub-Health Measurement Scale version 1.0 (SHMS V1.0) and Occupational Stress Inventory-Revised Edition (OSI-R) . Results: Detection rate of sub-health status among Tianjin middle school teachers was 58.55%. Men had significantly lower sub-health detection rate (55.19%) than women (59.71%) . Sub-health detection rate increased with age ( P <0.05) , the sub-health detection rate among middle school teachers more than 50 years old was the highest (66.84%) . The mean score of OSI-R was 403.18±41.80 with the scores of 176.00±21.05, 103.17±17.53, and 124.02±20.28 for ORQ, PSQ, PRQ, respectively, which showed significantly difference compared with the occupational stress norm of China ( P <0.001) . The mean scores of OSI-R, ORQ, PSQ, PRQ in different health status were significantly different ( P <0.001) . The partial correlation analysis between the scores of sub-health and occupational stress of middle school teachers showed that the scores of occupational role and personal strain were negatively correlated with the scores of sub-health state ( P < 0.001) , while, there was significantly positive correlation between the scores of personal resource and the scores of sub-health state ( P <0.001) . Conclusion: Sub-health detection rate of middle school teachers in Tianjin is higher. Effective measures should be taken to appropriately mitigate the occupational stress level of middle school teachers, increase personal resources, and scientific and effective health guidance and education should be strengthened.

  1. Detecting altered connectivity patterns in HIV associated neurocognitive impairment using mutual connectivity analysis

    NASA Astrophysics Data System (ADS)

    Abidin, Anas Zainul; D'Souza, Adora M.; Nagarajan, Mahesh B.; Wismüller, Axel

    2016-03-01

    The use of functional Magnetic Resonance Imaging (fMRI) has provided interesting insights into our understanding of the brain. In clinical setups these scans have been used to detect and study changes in the brain network properties in various neurological disorders. A large percentage of subjects infected with HIV present cognitive deficits, which are known as HIV associated neurocognitive disorder (HAND). In this study we propose to use our novel technique named Mutual Connectivity Analysis (MCA) to detect differences in brain networks in subjects with and without HIV infection. Resting state functional MRI scans acquired from 10 subjects (5 HIV+ and 5 HIV-) were subject to standard preprocessing routines. Subsequently, the average time-series for each brain region of the Automated Anatomic Labeling (AAL) atlas are extracted and used with the MCA framework to obtain a graph characterizing the interactions between them. The network graphs obtained for different subjects are then compared using Network-Based Statistics (NBS), which is an approach to detect differences between graphs edges while controlling for the family-wise error rate when mass univariate testing is performed. Applying this approach on the graphs obtained yields a single network encompassing 42 nodes and 65 edges, which is significantly different between the two subject groups. Specifically connections to the regions in and around the basal ganglia are significantly decreased. Also some nodes corresponding to the posterior cingulate cortex are affected. These results are inline with our current understanding of pathophysiological mechanisms of HIV associated neurocognitive disease (HAND) and other HIV based fMRI connectivity studies. Hence, we illustrate the applicability of our novel approach with network-based statistics in a clinical case-control study to detect differences connectivity patterns.

  2. Rapid spread and association of Schmallenberg virus with ruminant abortions and foetal death in Austria in 2012/2013.

    PubMed

    Steinrigl, Adolf; Schiefer, Peter; Schleicher, Corina; Peinhopf, Walter; Wodak, Eveline; Bagó, Zoltán; Schmoll, Friedrich

    2014-10-15

    Schmallenberg virus (SBV) has emerged in summer-autumn 2011 in north-western Europe. Since then, SBV has been continuously spreading over Europe, including Austria, where antibodies to SBV, as well as SBV genome, were first detected in autumn 2012. This study was performed to demonstrate the dynamics of SBV spread within Austria, after its probable first introduction in summer 2012. True seroprevalence estimates for cattle and small ruminates were calculated to demonstrate temporal and regional differences of infection. Furthermore, the probability of SBV genome detection in foetal tissues of aborted or stillborn cattle and small ruminants as well as in allantoic fluid samples from cows with early foetal losses was retrospectively assessed. SBV first reached Austria most likely in July-August 2012, as indicated by retrospective detection of SBV antibodies and SBV genome in archived samples. From August to October 2012, a rapid increase in seroprevalence to over 98% in cattle and a contemporaneous peak in the detection of SBV genome in foetal tissues and allantoic fluid samples was noted, indicating widespread acute infections. Notably, foetal malformations were absent in RT-qPCR positive foetuses at this time of the epidemic. SBV spread within Austrian cattle reached a plateau phase as early as October 2012, without significant regional differences in SBV seroprevalence (98.4-100%). Estimated true seroprevalences among small ruminates were comparatively lower than in cattle and regionally different (58.3-95.6% in October 2012), potentially indicating an eastward spread of the infection, as well as different infection dynamics between cattle and small ruminants. Additionally, the probability of SBV genome detection over time differed significantly between small ruminant and cattle samples subjected to RT-qPCR testing. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Quantifying the utilization of medical devices necessary to detect postmarket safety differences: A case study of implantable cardioverter defibrillators.

    PubMed

    Bates, Jonathan; Parzynski, Craig S; Dhruva, Sanket S; Coppi, Andreas; Kuntz, Richard; Li, Shu-Xia; Marinac-Dabic, Danica; Masoudi, Frederick A; Shaw, Richard E; Warner, Frederick; Krumholz, Harlan M; Ross, Joseph S

    2018-06-12

    To estimate medical device utilization needed to detect safety differences among implantable cardioverter defibrillators (ICDs) generator models and compare these estimates to utilization in practice. We conducted repeated sample size estimates to calculate the medical device utilization needed, systematically varying device-specific safety event rate ratios and significance levels while maintaining 80% power, testing 3 average adverse event rates (3.9, 6.1, and 12.6 events per 100 person-years) estimated from the American College of Cardiology's 2006 to 2010 National Cardiovascular Data Registry of ICDs. We then compared with actual medical device utilization. At significance level 0.05 and 80% power, 34% or fewer ICD models accrued sufficient utilization in practice to detect safety differences for rate ratios <1.15 and an average event rate of 12.6 events per 100 person-years. For average event rates of 3.9 and 12.6 events per 100 person-years, 30% and 50% of ICD models, respectively, accrued sufficient utilization for a rate ratio of 1.25, whereas 52% and 67% for a rate ratio of 1.50. Because actual ICD utilization was not uniformly distributed across ICD models, the proportion of individuals receiving any ICD that accrued sufficient utilization in practice was 0% to 21%, 32% to 70%, and 67% to 84% for rate ratios of 1.05, 1.15, and 1.25, respectively, for the range of 3 average adverse event rates. Small safety differences among ICD generator models are unlikely to be detected through routine surveillance given current ICD utilization in practice, but large safety differences can be detected for most patients at anticipated average adverse event rates. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Effect of storage, processing and cooking on glucosinolate content of Brassica vegetables.

    PubMed

    Song, Lijiang; Thornalley, Paul J

    2007-02-01

    Epidemiological studies have shown that consumption of Brassica vegetables decrease the risk of cancer. These associations are linked to dietary intake of glucosinolates and their metabolism to cancer preventive isothiocyanates. Bioavailability of glucosinolates and related isothiocyanates are influenced by storage and culinary processing of Brassica vegetables. In this work, the content of the 7 major glucosinolates in broccoli, Brussels sprouts, cauliflower and green cabbage and their stability under different storage and cooking conditions is examined. Glucosinolates and isothiocyanates were quantified by liquid chromatography with tandem mass spectrometric detection (LC-MS/MS). Isothiocyanates were detected with high sensitivity as the corresponding thiourea derivatives. Storage at ambient temperature and in a domestic refrigerator showed no significant difference and a minor loss (9-26%) of glucosinolate levels over 7 days. Vegetables shredded finely showed a marked decline of glucosinolate level with post-shredding dwell time - up to 75% over 6h. Glucosinolate losses were detected partly as isothiocyanates. Cooking by steaming, microwaving and stir-fry did not produce significant loss of glucosinolates whereas boiling showed significant losses by leaching into cooking water. Most of the loss of the glucosinolates (approximately 90%) was detected in the cooking water. Increased bioavailability of dietary isothiocyanates may be achieved by avoiding boiling of vegetables.

  5. Abnormal Superior Temporal Connectivity During Fear Perception in Schizophrenia

    PubMed Central

    Leitman, David I.; Loughead, James; Wolf, Daniel H.; Ruparel, Kosha; Kohler, Christian G.; Elliott, Mark A.; Bilker, Warren B.; Gur, Raquel E.; Gur, Ruben C.

    2008-01-01

    Patients with schizophrenia have difficulty in decoding facial affect. A study using event–related functional neuroimaging indicated that errors in fear detection in schizophrenia are associated with paradoxically higher activation in the amygdala and an associated network implicated in threat detection. Furthermore, this exaggerated activation to fearful faces correlated with severity of flat affect. These findings suggest that abnormal threat detection processing may reflect disruptions between nodes that comprise the affective appraisal circuit. Here we examined connectivity within this network by determining the pattern of intercorrelations among brain regions (regions of interest) significantly activated during fear identification in both healthy controls and patients using a novel procedure CORANOVA. This analysis tests differences in the interregional correlation strength between schizophrenia and healthy controls. Healthy subjects' task activation was principally characterized by robust correlations between medial structures like thalamus (THA) and amygdala (AMY) and middle frontal (MF), inferior frontal (IF), and prefrontal cortical (PFC) regions. In contrast, schizophrenia patients displayed no significant correlations between the medial regions and either MF or IF. Further, patients had significantly higher correlations between occipital lingual gyrus and superior temporal gyrus than healthy subjects. These between-group connectivity differences suggest that schizophrenia threat detection impairment may stem from abnormal stimulus integration. Such abnormal integration may disrupt the evaluation of threat within fronto-cortical regions. PMID:18550592

  6. Prospective randomized controlled trial evaluating cap-assisted colonoscopy vs standard colonoscopy

    PubMed Central

    Tee, Hoi-Poh; Corte, Crispin; Al-Ghamdi, Hamdan; Prakoso, Emilia; Darke, John; Chettiar, Raman; Rahman, Wassim; Davison, Scott; Griffin, Sean P; Selby, Warwick S; Kaffes, Arthur J

    2010-01-01

    AIM: To study the significance of cap-fitted colonoscopy in improving cecal intubation time and polyp detection rate. METHODS: This study was a prospective randomized controlled trial conducted from March 2008 to February 2009 in a tertiary referral hospital at Sydney. The primary end point was cecal intubation time and the secondary endpoint was polyp detection rate. Consecutive cases of total colonoscopy over a 1-year period were recruited. Randomization into either standard colonoscopy (SC) or cap-assisted colonoscopy (CAC) was performed after consent was obtained. For cases randomized to CAC, one of the three sizes of cap was used: D-201-15004 (with a diameter of 15.3 mm), D-201-14304 (14.6 mm) and D-201-12704 (13.0 mm). All of these caps were produced by Olympus Medical Systems, Japan. Independent predictors for faster cecal time and better polyp detection rate were also determined from this study. RESULTS: There were 200 cases in each group. There was no significant difference in terms of demographic characteristics between the two groups. CAC, when compared to the SC group, had no significant difference in terms of cecal intubation rate (96.0% vs 97.0%, P = 0.40) and time (9.94 ± 7.05 min vs 10.34 ± 6.82 min, P = 0.21), or polyp detection rate (32.8% vs 31.3%, P = 0.75). On the subgroup analysis, there was no significant difference in terms of cecal intubation time by trainees (88.1% vs 84.8%, P = 0.40), ileal intubation rate (82.5% vs 79.0%, P = 0.38) or total colonoscopy time (23.24 ± 13.95 min vs 22.56 ± 9.94 min, P = 0.88). On multivariate analysis, the independent determinants of faster cecal time were consultant-performed procedures (P < 0.001), male patients (P < 0.001), non-usage of hyoscine (P < 0.001) and better bowel preparation (P = 0.01). The determinants of better polyp detection rate were older age (P < 0.001), no history of previous abdominal surgery (P = 0.04), patients not having esophagogastroduodenoscopy in the same setting (P = 0.003), trainee-performed procedures (P = 0.01), usage of hyoscine (P = 0.01) and procedures performed for polyp follow-up (P = 0.01). The limitations of the study were that it was a single-center experience, no blinding was possible, and there were a large number of endoscopists. CONCLUSION: CAC did not significantly different from SC in term of cecal intubation time and polyp detection rate. PMID:20712051

  7. Fate of thiamethoxam in mesocosms and response of the zooplankton community.

    PubMed

    Lobson, C; Luong, K; Seburn, D; White, M; Hann, B; Prosser, R S; Wong, C S; Hanson, M L

    2018-05-14

    Thiamethoxam is a neonicotinoid insecticide that can reach wetlands in agro-ecosystems through runoff. The fate and effects of thiamethoxam on non-target organisms in shallow wetland ecosystems have not been well characterized. To this end, a mesocosm study was conducted with a focus on characterizing zooplankton community responses. A single pulse application of thiamethoxam (0, 25, 50, 100, 250, and 500 μg/L; n = 3) was applied to experimental systems and monitored for 8 weeks. The mean half-life of thiamethoxam among the different treatments was 3.7 days in the water column with concentrations of <0.8 μg/L in the majority of mesocosms by 56 days. Principal response curve analysis did not show any significant concentration-dependent differences in the zooplankton community among treatments over the course of the study. The minimum detectable difference (MDD%) values for abundance of potentially sensitive arthropod taxa (nauplius larvae, cyclopoid copepods) allowed the detections from controls as low as 42 and 59% effect, respectively. The MDD% values for total abundance of zooplankton (including the potentially less sensitive taxonomic group of Rotifera) allowed the detection from controls as low as 41% effect. There were no statistically significant differences in zooplankton abundance or diversity between control and treated mesocosms at the end of the study. There were also no statistically significant differences for individual taxa that were sustained between sampling points, or manifested as a concentration-response. We conclude that acute exposure to thiamethoxam at environmentally relevant concentrations (typically ng/L) likely does not represent a significant adverse ecological risk to wetland zooplankton community abundance and structure. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Dedicated Barrett's surveillance sessions managed by trained endoscopists improve dysplasia detection rate.

    PubMed

    Ooi, Joanne; Wilson, Patrick; Walker, Giles; Blaker, Paul; DeMartino, Sabina; O'Donohue, John; Reffitt, David; Lanaspre, Effie; Chang, Fuju; Meenan, John; Dunn, Jason M

    2017-06-01

    Background and study aim  Barrett's esophagus (BE)-associated dysplasia is an important marker for risk of progression to esophageal adenocarcinoma (EAC) and an indication for endoscopic therapy. However, BE surveillance technique is variable. The aim of this study was to assess the effect of dedicated BE surveillance lists on dysplasia detection rate (DDR). Patients and methods  This was a prospective study of patients undergoing BE surveillance at two hospitals - community (UHL) and upper gastrointestinal center (GSTT). Four endoscopists (Group A) were trained in Prague classification, Seattle protocol biopsy technique, and lesion detection prior to performing BE surveillance endoscopies at both sites, with dedicated time slots or lists. The DDR was then compared with historical data from 47 different endoscopists at GSTT and 24 at UHL (Group B) who had undertaken Barrett's surveillance over the preceding 5-year period. Results  A total of 729 patients with BE underwent surveillance endoscopy between 2007 and 2012. There was no significant difference in patient age, sex, or length of BE between the two groups. There was a significant difference in detection rate of confirmed indefinite or low grade dysplasia and high grade dysplasia (HGD)/EAC between the two groups: 18 % (26 /142) Group A vs. 8 % (45/587) in Group B ( P  < 0.001). Documentation of Prague criteria and adherence to the Seattle protocol was significantly higher in Group A. Conclusion  This study demonstrated that a group of trained endoscopists undertaking Barrett's surveillance on dedicated lists had significantly higher DDR than a nonspecialist cohort. These findings support the introduction of dedicated Barrett's surveillance lists. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Detection and attribution of vegetation greening trend in China over the last 30 years.

    PubMed

    Piao, Shilong; Yin, Guodong; Tan, Jianguang; Cheng, Lei; Huang, Mengtian; Li, Yue; Liu, Ronggao; Mao, Jiafu; Myneni, Ranga B; Peng, Shushi; Poulter, Ben; Shi, Xiaoying; Xiao, Zhiqiang; Zeng, Ning; Zeng, ZhenZhong; Wang, Yingping

    2015-04-01

    The reliable detection and attribution of changes in vegetation growth is a prerequisite for the development of strategies for the sustainable management of ecosystems. This is an extraordinary challenge. To our knowledge, this study is the first to comprehensively detect and attribute a greening trend in China over the last three decades. We use three different satellite-derived Leaf Area Index (LAI) datasets for detection as well as five different process-based ecosystem models for attribution. Rising atmospheric CO2 concentration and nitrogen deposition are identified as the most likely causes of the greening trend in China, explaining 85% and 41% of the average growing-season LAI trend (LAIGS) estimated by satellite datasets (average trend of 0.0070 yr(-1), ranging from 0.0035 yr(-1) to 0.0127 yr(-1)), respectively. The contribution of nitrogen deposition is more clearly seen in southern China than in the north of the country. Models disagree about the contribution of climate change alone to the trend in LAIGS at the country scale (one model shows a significant increasing trend, whereas two others show significant decreasing trends). However, the models generally agree on the negative impacts of climate change in north China and Inner Mongolia and the positive impact in the Qinghai-Xizang plateau. Provincial forest area change tends to be significantly correlated with the trend of LAIGS (P < 0.05), and marginally significantly (P = 0.07) correlated with the residual of LAIGS trend, calculated as the trend observed by satellite minus that estimated by models through considering the effects of climate change, rising CO2 concentration and nitrogen deposition, across different provinces. This result highlights the important role of China's afforestation program in explaining the spatial patterns of trend in vegetation growth. © 2014 John Wiley & Sons Ltd.

  10. Assessing operating characteristics of CAD algorithms in the absence of a gold standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.

    2010-04-15

    Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range ofmore » operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.« less

  11. Coronal Holes and Solar f -Mode Wave Scattering Off Linear Boundaries

    NASA Astrophysics Data System (ADS)

    Hess Webber, Shea A.

    2016-11-01

    Coronal holes (CHs) are solar atmospheric features that have reduced emission in the extreme ultraviolet (EUV) spectrum due to decreased plasma density along open magnetic field lines. CHs are the source of the fast solar wind, can influence other solar activity, and track the solar cycle. Our interest in them deals with boundary detection near the solar surface. Detecting CH boundaries is important for estimating their size and tracking their evolution through time, as well as for comparing the physical properties within and outside of the feature. In this thesis, we (1) investigate CHs using statistical properties and image processing techniques on EUV images to detect CH boundaries in the low corona and chromosphere. SOHO/EIT data is used to locate polar CH boundaries on the solar limb, which are then tracked through two solar cycles. Additionally, we develop an edge-detection algorithm that we use on SDO/AIA data of a polar hole extension with an approximately linear boundary. These locations are used later to inform part of the helioseismic investigation; (2) develop a local time-distance (TD) helioseismology technique that can be used to detect CH boundary signatures at the photospheric level. We employ a new averaging scheme that makes use of the quasi-linear topology of elongated scattering regions, and create simulated data to test the new technique and compare results of some associated assumptions. This method enhances the wave propagation signal in the direction perpendicular to the linear feature and reduces the computational time of the TD analysis. We also apply a new statistical analysis of the significance of differences between the TD results; and (3) apply the TD techniques to solar CH data from SDO/HMI. The data correspond to the AIA data used in the edge-detection algorithm on EUV images. We look for statistically significant differences between the TD results inside and outside the CH region. In investigation (1), we found that the polar CH areas did not change significantly between minima, even though the magnetic field strength weakened. The results of (2) indicate that TD helioseismology techniques can be extended to make use of feature symmetry in the domain. The linear technique used here produces results that differ between a linear scattering region and a circular scattering region, shown using the simulated data algorithm. This suggests that using usual TD methods on scattering regions that are radially asymmetric may produce results with signatures of the anisotropy. The results of (1) and (3) indicate that the TD signal within our CH is statistically significantly different compared to unrelated quiet sun results. Surprisingly, the TD results in the quiet sun near the CH boundary also show significant differences compared to the separate quiet sun.

  12. Occurrence and distribution of organic chemicals and nutrients and comparison of water-quality data from public drinking-water supplies in the Columbia aquifer in Delaware, 2000-08

    USGS Publications Warehouse

    Reyes, Betzaida

    2010-01-01

    The U.S. Geological Survey, in cooperation with the Delaware Department of Natural Resources and Environmental Control and the Delaware Geological Survey, conducted a groundwater-quality investigation to (a) describe the occurrence and distribution of selected contaminants, and (b) document any changes in groundwater quality in the Columbia aquifer public water-supply wells in the Coastal Plain in Delaware between 2000 and 2008. Thirty public water-supply wells located throughout the Columbia aquifer of the Delaware Coastal Plain were sampled from August through November of 2008. Twenty-two of the wells in the sampling network for this project were previously sampled in 2000. Eight new wells were selected to replace wells no longer in use. Groundwater collected from the wells was analyzed for the occurrence and distribution of selected pesticides, pesticide degradates, volatile organic compounds, nutrients, and major inorganic ions. Nine of the wells were analyzed for radioactive elements (radium-226, radium-228, and radon). Groundwater-quality data were compared for sites sampled in both 2000 and 2008 to document any changes in water quality. One or more pesticides were detected in samples from 29 of the 30 wells. There were no significant differences in pesticide and pesticide degradate concentrations and similar compounds were detected when comparing sampling results from 2000 and 2008. Pesticide and pesticide degradate concentrations were generally less than 1 microgram per liter. Twenty-four compounds, 14 pesticides, and 10 pesticide degradates were detected in at least one sample; the pesticide degradates, metolachlor ethanesulfonic acid, deethylatrazine, and alachlor ethanesulfonic acid were the most frequently detected compounds, each found in more than 50 percent of samples. Almost 80 percent of the detected pesticides were agricultural herbicides, which reflects the prevalence and wide distribution of agriculture in sampled areas, as well the dominance of agricultural pesticides among the target analytes for this study. No concentration of a pesticide or pesticide degradate exceeded any regulatory standard. Dieldrin, an insecticide that has been banned for several decades, was detected at a concentration that exceeded a non-regulatory health-based screening level of 0.002 micrograms per liter at nine sites. Volatile organic compounds (VOCs) were generally detected at concentrations of less than 1 microgram per liter, although 7 of the 31 detected VOCs had concentrations greater than 1 microgram per liter. There were no significant differences in VOC concentrations from 2000 to 2008; however, among the resampled wells, the mean number of VOCs detected per well was significantly different over the 8-year period. The number of VOCs detected per well decreased in 73 percent of the resampled wells; the decrease ranged from one to eight fewer detections in 2008 than in 2000. Chloroform and methyl tert-butyl ether were the most frequently detected VOCs, at 90 percent and 63 percent, respectively, among the 30 wells. Solvents were the most frequently detected class of VOCs. All measured concentrations of VOCs in groundwater were below established standards for drinking water and below other health-based guidelines. There were no significant differences in nutrient or major-ion concentrations between 2000 and 2008, however, the medians of two field measurements, pH and dissolved oxygen, were significantly higher in 2008 than in 2000 in the resampled wells. Although pH and dissolved oxygen were higher, water was still acidic and predominantly oxic. Nitrate was the predominant nutrient species in the Columbia aquifer, with a 90-percent detection frequency. The median nitrate concentration in groundwater was 4.88 milligrams per liter, which was slightly lower than, but not significantly different from, the median of 5.23 milligrams per liter for the 2000 samples. Concentrations of nitrate exceeded the U.S. Environmental Protection Agency's Maximum Contaminant Level or Federal drinking-water standard of 10 milligrams per liter as nitrogen in samples from two wells. Eight of the 30 wells sampled had iron or manganese concentrations that exceeded the U.S. Environmental Protection Agency's Secondary Maximum Contaminant Level; nine samples exceeded the Health Advisory Limit set by the Delaware Division of Public Health of 20 milligrams per liter for sodium in drinking water. Two radiochemical isotopes, radium-226 and radon-222, were detected in all nine groundwater samples analyzed; five samples had detectable levels of radium-228 activity. None of the samples exceeded the U.S Environmental Protection Agency's Maximum Contaminant Level for radium or radon in drinking water. Although radioactive elements were more frequently detected in 2008 than in 2000, this increased detection frequency is more likely due to lower detection levels in 2008 than 2000. The average age of groundwater entering the screens of the production wells sampled in 2008 ranged from 6 to 35 years, with a median groundwater age of 22 years. Groundwater age was positively correlated with well depth and negatively correlated with dissolved oxygen. Data from the 22 resampled wells indicate a significant positive difference in the average modeled groundwater-sample-age results. The average groundwater age from samples collected in 2008 was generally 7 years older than the average groundwater age from samples collected in 2000.

  13. Statistical significance of task related deep brain EEG dynamic changes in the time-frequency domain.

    PubMed

    Chládek, J; Brázdil, M; Halámek, J; Plešinger, F; Jurák, P

    2013-01-01

    We present an off-line analysis procedure for exploring brain activity recorded from intra-cerebral electroencephalographic data (SEEG). The objective is to determine the statistical differences between different types of stimulations in the time-frequency domain. The procedure is based on computing relative signal power change and subsequent statistical analysis. An example of characteristic statistically significant event-related de/synchronization (ERD/ERS) detected across different frequency bands following different oddball stimuli is presented. The method is used for off-line functional classification of different brain areas.

  14. A Study of Electronic Detection and Pedagogical Approaches for Reducing Plagiarism

    ERIC Educational Resources Information Center

    Chao, Chia-An; Wilhelm, William J.; Neureuther, Brian D.

    2009-01-01

    Plagiarism is an increasing problem in high schools and universities. To address the issue of how to teach students not to plagiarize, this study examined several pedagogical approaches for reducing plagiarism and the use of Turnitin, an online plagiarism detection software. The study found a significant difference between the control group and…

  15. 76 FR 8278 - Special Conditions: Gulfstream Model GVI Airplane; Enhanced Flight Vision System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-14

    ... detected by infrared sensors can be much different from that detected by natural pilot vision. On a dark... by many imaging infrared systems. On the other hand, contrasting colors in visual wavelengths may be... of the EFVS image and the level of EFVS infrared sensor performance could depend significantly on...

  16. Assessment of interplay between UV wavelengths, material surfaces and food residues in open surface hygiene validation.

    PubMed

    Abban, Stephen; Jakobsen, Mogens; Jespersen, Lene

    2014-12-01

    The use of UV-visible radiation for detecting invisible residue on different surfaces as a means of validating cleanliness was investigated. Wavelengths at 365, 395, 435, 445, 470 and 490 nm from a monochromator were used to detect residues of beef, chicken, apple, mango and skim milk. These were on three surfaces: aluminium, fibre re-enforced plastic (FRP; Q-Liner®) and stainless steel, pre- and post a cleaning step using commercial detergent. The area covered by residues as detected by specific wavelengths was compared statistically. The sensitivity of the wavelengths for detection differed significantly (p < 0.05) for various residues depending on the material surfaces. Generally, wavelengths 365-445 nm were consistently able to illuminate all residue before cleaning, though sensitivity varied, while 490 nm showed more of the surface structural features instead of residue. The 365-395 nm wavelengths were significantly more sensitive (p < 0.05) for detecting beef and chicken residues on aluminium and stainless steel both before and after cleaning. The 435-445 nm wavelengths were significantly more sensitive for detecting apple and mango residues on the FRP both before and after cleaning. It is important when UV-systems are used as real-time tools for assessing cleanliness of surfaces that the surface materials being illuminated are taken into account in the choice of lamp wavelength, in addition to expected residue. This will ensure higher confidence in results during the use of UV-light for real-time hygiene validation of surfaces.

  17. Giant Gold Nanowire Vesicle-Based Colorimetric and SERS Dual-Mode Immunosensor for Ultrasensitive Detection of Vibrio parahemolyticus.

    PubMed

    Guo, Zhiyong; Jia, Yaru; Song, Xinxin; Lu, Jing; Lu, Xuefei; Liu, Baoqing; Han, Jiaojiao; Huang, Youju; Zhang, Jiawei; Chen, Tao

    2018-05-15

    Conventional methods for the detection of Vibrio parahemolyticus (VP) usually need tedious, labor-intensive processes, and have low sensitivity, which further limits their practical applications. Herein, we developed a simple and efficient colorimetry and surface-enhanced Raman scattering (SERS) dual-mode immunosensor for sensitive detection of VP, by employing giant Au vesicles with anchored tiny gold nanowires (AuNW) as a smart probe. Due to the larger specific surface and special hollow structure of giant Au vesicles, silver staining would easily lead to vivid color change for colorimetric analysis and further amplify SERS signals. The t-test was further used to determine if two sets of data from colorimetry and SERS were significantly different from each other. The result shows that there was no significant difference between data from the two methods. Two sets of data can mutually validate each other and avoid false positive and negative detection. The designed colorimetry-SERS dual-mode sensor would be very promising in various applications such as food safety inspection, personal healthcare, and on-site environmental monitoring.

  18. Power spectrum weighted edge analysis for straight edge detection in images

    NASA Astrophysics Data System (ADS)

    Karvir, Hrishikesh V.; Skipper, Julie A.

    2007-04-01

    Most man-made objects provide characteristic straight line edges and, therefore, edge extraction is a commonly used target detection tool. However, noisy images often yield broken edges that lead to missed detections, and extraneous edges that may contribute to false target detections. We present a sliding-block approach for target detection using weighted power spectral analysis. In general, straight line edges appearing at a given frequency are represented as a peak in the Fourier domain at a radius corresponding to that frequency, and a direction corresponding to the orientation of the edges in the spatial domain. Knowing the edge width and spacing between the edges, a band-pass filter is designed to extract the Fourier peaks corresponding to the target edges and suppress image noise. These peaks are then detected by amplitude thresholding. The frequency band width and the subsequent spatial filter mask size are variable parameters to facilitate detection of target objects of different sizes under known imaging geometries. Many military objects, such as trucks, tanks and missile launchers, produce definite signatures with parallel lines and the algorithm proves to be ideal for detecting such objects. Moreover, shadow-casting objects generally provide sharp edges and are readily detected. The block operation procedure offers advantages of significant reduction in noise influence, improved edge detection, faster processing speed and versatility to detect diverse objects of different sizes in the image. With Scud missile launcher replicas as target objects, the method has been successfully tested on terrain board test images under different backgrounds, illumination and imaging geometries with cameras of differing spatial resolution and bit-depth.

  19. Factors Influencing Performance of Internet-Based Biosurveillance Systems Used in Epidemic Intelligence for Early Detection of Infectious Diseases Outbreaks

    PubMed Central

    Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M.; Nelson, Noele P.; Mawudeku, Abla; Madoff, Lawrence C.; Linge, Jens P.; Collier, Nigel; Brownstein, John S.; Astagneau, Pascal

    2014-01-01

    Background Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Method and Findings Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems’ performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p = 0001) whereas other indicators were similar (C-DR: p = 020; C-Se, p = 013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Conclusion Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p = 00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases were found to influence system performance. PMID:24599062

  20. Factors influencing performance of internet-based biosurveillance systems used in epidemic intelligence for early detection of infectious diseases outbreaks.

    PubMed

    Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M; Nelson, Noele P; Mawudeku, Abla; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Astagneau, Pascal

    2014-01-01

    Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems' performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p=0001) whereas other indicators were similar (C-DR: p=020; C-Se, p=013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p=00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases were found to influence system performance.

  1. The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS

    PubMed Central

    Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan

    2015-01-01

    Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS. PMID:26554930

  2. The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS.

    PubMed

    Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan

    2015-01-01

    Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.

  3. Microbiological and mycological beach sand quality in a volcanic environment: Madeira archipelago, Portugal.

    PubMed

    Pereira, Elisabete; Figueira, Celso; Aguiar, Nuno; Vasconcelos, Rita; Vasconcelos, Sílvia; Calado, Graça; Brandão, João; Prada, Susana

    2013-09-01

    Madeira forms a mid-Atlantic volcanic archipelago, whose economy is largely dependent on tourism. There, one can encounter different types of sand beach: natural basaltic, natural calcareous and artificial calcareous. Microbiological and mycological quality of the sand was analyzed in two different years. Bacterial indicators were detected in higher number in 2010 (36.7% of the samples) than in 2011 (9.1%). Mycological indicators were detected in a similar percentage of samples in 2010 (68.3%) and 2011 (75%), even though the total number of colonies detected in 2010 was much higher (827 in 41 samples) than in 2011 (427 in 66 samples). Enterococci and potentially pathogenic and allergenic fungi (particularly Penicillium sp.) were the most common indicators detected in both years. Candida sp. yeast was also commonly detected in the samples. The analysis of the 3rd quartile and maximum numbers of all indicators in samples showed that artificial beaches tend to be more contaminated than the natural ones. However, a significant difference between the variables was lacking. More monitoring data (number of bathers, sea birds, radiation intensity variation, and a greater number of samples) should be collected in order to confirm if these differences are significant. In general, the sand quality in the archipelago's beaches was good. As the sand may be a vector of diseases, an international common set of indicators and values and a compatible methodologies for assessing sand contamination, should be defined, in order to provide the bather's with an indication of beach sand quality, rather than only the water. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Seasonal distribution and prevalence of diarrheagenic Escherichia coli in different aquatic environments in Taiwan.

    PubMed

    Huang, Wen-Chien; Hsu, Bing-Mu; Kao, Po-Min; Tao, Chi-Wei; Ho, Ying-Ning; Kuo, Chun-Wei; Huang, Yu-Li

    2016-02-01

    Diarrheagenic Escherichia coli (DEC) are the most common agents of diarrhea. Waterborne DEC could pose a potential health risk to human through agricultural, household, recreational, and industrial use. There are few published reports on the detection of DEC and its seasonal distribution in aquatic environments. The presence of DEC in different types of aquatic environments was investigated in this study. Water samples were collected from major rivers, water reservoirs, and recreational hot springs throughout Taiwan. Moreover, an intensive water sampling plan was carried out along Puzih River. The detection of DEC target genes was used to determine the presence of enterotoxigenic E. coli (ETEC), enteropathogenic E. coli (EPEC), and Shiga toxin-producing E. coli (STEC). Among the 383 water samples analyzed, DEC was found in 122 (31.8%) samples. The detection rate varied by genotype, raging from 3.6% for STEC to 17.2% for EPEC. The DEC detection rate was higher from river waters than reservoirs and hot springs. In addition, DEC was detected at a higher rate in spring and summer. The presence of EPEC was significantly associated with total coliform levels among hot spring samples. Moreover, the presence of ETEC in river water samples was associated with heterotrophic plate counts. Water with EPEC differed significantly in pH from Puzih River samples. These results suggest that seasonal characteristics may affect the presence of DEC in different aquatic environments, and water quality indicators may be indicative of the presence of DEC. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Toxin Detection by Surface Plasmon Resonance

    PubMed Central

    Hodnik, Vesna; Anderluh, Gregor

    2009-01-01

    Significant efforts have been invested in the past years for the development of analytical methods for fast toxin detection in food and water. Immunochemical methods like ELISA, spectroscopy and chromatography are the most used in toxin detection. Different methods have been linked, e.g. liquid chromatography and mass spectrometry (LC-MS), in order to detect as low concentrations as possible. Surface plasmon resonance (SPR) is one of the new biophysical methods which enables rapid toxin detection. Moreover, this method was already included in portable sensors for on-site determinations. In this paper we describe some of the most common methods for toxin detection, with an emphasis on SPR. PMID:22573957

  6. Do obesity and weight loss affect vocal function?

    PubMed

    Solomon, Nancy Pearl; Helou, Leah B; Dietrich-Burns, Katie; Stojadinovic, Alexander

    2011-02-01

    Obesity may be associated with increased tissue bulk in the laryngeal airway, neck, and chest wall, and as such may affect vocal function. Eight obese and eight nonobese adults participated in this study; the obese participants underwent bariatric surgical procedures. This mixed-design study included cross-sectional analysis for group differences and longitudinal analysis for multidimensional changes in vocal function from four assessments collected over 6 months. No significant differences were detected between groups from the preoperative assessment. Further, no changes were detected over time for acoustic parameters, maximum phonation time, laryngeal airway resistance, and airflow during a sustained vowel for either group. Only minor differences were detected for strain, pitch, and loudness perceptions of voice over time, but not between groups. Phonation threshold pressure (PTP), at comfortable and high pitches (30% and 80% of the F0 range) changed significantly over time, but not between groups. Examination of individual data revealed a trend for PTP at 30% F0 to decrease as body mass index decreased. PTP may be informative for assessing vocal function in clients who present with obesity and voice symptoms. © Thieme Medical Publishers.

  7. Analysis of copy number variants by three detection algorithms and their association with body size in horses.

    PubMed

    Metzger, Julia; Philipp, Ute; Lopes, Maria Susana; da Camara Machado, Artur; Felicetti, Michela; Silvestrelli, Maurizio; Distl, Ottmar

    2013-07-18

    Copy number variants (CNVs) have been shown to play an important role in genetic diversity of mammals and in the development of many complex phenotypic traits. The aim of this study was to perform a standard comparative evaluation of CNVs in horses using three different CNV detection programs and to identify genomic regions associated with body size in horses. Analysis was performed using the Illumina Equine SNP50 genotyping beadchip for 854 horses. CNVs were detected by three different algorithms, CNVPartition, PennCNV and QuantiSNP. Comparative analysis revealed 50 CNVs that affected 153 different genes mainly involved in sensory perception, signal transduction and cellular components. Genome-wide association analysis for body size showed highly significant deleted regions on ECA1, ECA8 and ECA9. Homologous regions to the detected CNVs on ECA1 and ECA9 have also been shown to be correlated with human height. Comparative analysis of CNV detection algorithms was useful to increase the specificity of CNV detection but had certain limitations dependent on the detection tool. GWAS revealed genome-wide associated CNVs for body size in horses.

  8. Deep learning on temporal-spectral data for anomaly detection

    NASA Astrophysics Data System (ADS)

    Ma, King; Leung, Henry; Jalilian, Ehsan; Huang, Daniel

    2017-05-01

    Detecting anomalies is important for continuous monitoring of sensor systems. One significant challenge is to use sensor data and autonomously detect changes that cause different conditions to occur. Using deep learning methods, we are able to monitor and detect changes as a result of some disturbance in the system. We utilize deep neural networks for sequence analysis of time series. We use a multi-step method for anomaly detection. We train the network to learn spectral and temporal features from the acoustic time series. We test our method using fiber-optic acoustic data from a pipeline.

  9. Herbicides and nitrate in near-surface aquifers in the midcontinental United States, 1991

    USGS Publications Warehouse

    Kolpin, Dana W.; Burkart, Michael R.; Thurman, E. Michael

    1994-01-01

    Hydrogeologic factors, land use, agricultural practices, local features, and water chemistry were analyzed for possible relation to herbicide and excess-nitrate detections. Herbicides and excess nitrate were detected more frequently in near-surface unconsolidated aquifers than in nearsurface bedrock aquifers. The depth to the top of the aquifer was inversely related to the frequency of detection of herbicides and excess nitrate. The proximity of streams to sampled wells also affected the frequency of herbicide detection. Significant seasonal differences were determined for the frequency of herbicide detection, but not for the frequency of excess nitrate.

  10. Meal Microstructure Characterization from Sensor-Based Food Intake Detection.

    PubMed

    Doulah, Abul; Farooq, Muhammad; Yang, Xin; Parton, Jason; McCrory, Megan A; Higgins, Janine A; Sazonov, Edward

    2017-01-01

    To avoid the pitfalls of self-reported dietary intake, wearable sensors can be used. Many food ingestion sensors offer the ability to automatically detect food intake using time resolutions that range from 23 ms to 8 min. There is no defined standard time resolution to accurately measure ingestive behavior or a meal microstructure. This paper aims to estimate the time resolution needed to accurately represent the microstructure of meals such as duration of eating episode, the duration of actual ingestion, and number of eating events. Twelve participants wore the automatic ingestion monitor (AIM) and kept a standard diet diary to report their food intake in free-living conditions for 24 h. As a reference, participants were also asked to mark food intake with a push button sampled every 0.1 s. The duration of eating episodes, duration of ingestion, and number of eating events were computed from the food diary, AIM, and the push button resampled at different time resolutions (0.1-30s). ANOVA and multiple comparison tests showed that the duration of eating episodes estimated from the diary differed significantly from that estimated by the AIM and the push button ( p -value <0.001). There were no significant differences in the number of eating events for push button resolutions of 0.1, 1, and 5 s, but there were significant differences in resolutions of 10-30s ( p -value <0.05). The results suggest that the desired time resolution of sensor-based food intake detection should be ≤5 s to accurately detect meal microstructure. Furthermore, the AIM provides more accurate measurement of the eating episode duration than the diet diary.

  11. Meal Microstructure Characterization from Sensor-Based Food Intake Detection

    PubMed Central

    Doulah, Abul; Farooq, Muhammad; Yang, Xin; Parton, Jason; McCrory, Megan A.; Higgins, Janine A.; Sazonov, Edward

    2017-01-01

    To avoid the pitfalls of self-reported dietary intake, wearable sensors can be used. Many food ingestion sensors offer the ability to automatically detect food intake using time resolutions that range from 23 ms to 8 min. There is no defined standard time resolution to accurately measure ingestive behavior or a meal microstructure. This paper aims to estimate the time resolution needed to accurately represent the microstructure of meals such as duration of eating episode, the duration of actual ingestion, and number of eating events. Twelve participants wore the automatic ingestion monitor (AIM) and kept a standard diet diary to report their food intake in free-living conditions for 24 h. As a reference, participants were also asked to mark food intake with a push button sampled every 0.1 s. The duration of eating episodes, duration of ingestion, and number of eating events were computed from the food diary, AIM, and the push button resampled at different time resolutions (0.1–30s). ANOVA and multiple comparison tests showed that the duration of eating episodes estimated from the diary differed significantly from that estimated by the AIM and the push button (p-value <0.001). There were no significant differences in the number of eating events for push button resolutions of 0.1, 1, and 5 s, but there were significant differences in resolutions of 10–30s (p-value <0.05). The results suggest that the desired time resolution of sensor-based food intake detection should be ≤5 s to accurately detect meal microstructure. Furthermore, the AIM provides more accurate measurement of the eating episode duration than the diet diary. PMID:28770206

  12. Comparative evaluation of the oral tactile function by means of teeth or implant-supported prostheses.

    PubMed

    Jacobs, R; van Steenberghe, D

    1991-01-01

    To clarify more of the tactile function of oral implants, both an interocclusal thickness detection and discrimination task were carried out in 4 different test conditions on 37 patients: t (tooth)/t, i (implant)/t, i/i and d (denture)/o (overdenture supported by implants). For the interocclusal detection of steel foils, the 50% detection threshold level (RL) in the 4 conditions was 20, 48, 64 and 108 microns, respectively, which indicates significant differences. The ability to discriminate interdental thickness differences was tested with a 0.2 and 1.0 mm standard. It was evaluated as the 75% discrimination level (DL). In the 0.2 mm discrimination task, corresponding DL-values for the t/t, i/t, i/i and d/o condition were 25, 55, 66 and 134 microns, whereas the 1.0 mm standard gave values of 193, 293, 336 and 348 microns, respectively. All results differed significantly from each other (p less than 0.05) except for the i/i-d/o comparison of the 1.0 mm discrimination task where the difference was negligible. The present findings indicate that the tactile sensibility of implants is reduced with regard to natural teeth. Remaining receptors of the peri-implant tissues might play a compensatory role in the decreased exteroceptive function.

  13. An Analysis of the Malassezia Species Distribution in the Skin of Patients with Pityriasis Versicolor in Chengdu, China

    PubMed Central

    Xie, Zhen; Ran, Yuping; Zhang, Hao; Zhang, Min; Wan, Huiying; Li, Conghui

    2014-01-01

    Pityriasis versicolor (PV) is a common clinical problem associated with Malassezia species (Malassezia spp.). Controversies remain regarding the specific species involved in the development of PV. This study analyzed the difference in Malassezia spp. distribution in lesional and nonlesional skin in Chinese PV patients. A paired design was applied. Lesional and nonlesional scales from 24 cases were collected; real-time fluorescence quantitative PCR was used to detect 10 different Malassezia spp. In lesional skin, the highest detection rates were for M. globosa (95.8%), M. restricta (91.7%), and M. sympodialis (50.0%). In nonlesional skin, the highest detection rates were for M. globosa (87.5%), M. restricta (79.2%), and M. dermatis (33.3%). A significant difference in the detection rate was only found for M. sympodialis (50.8% versus 20.8%, P = 0.04). Compared with nonlesional skin, the amount of M. globosa, M. restricta, and M. sympodialis in lesional skin was significantly higher (3.8 ± 1.3,  2.5 ± 1.1, and 3.2 ± 1.6 times higher, resp.). The results of this study do not indicate that M. globosa and M. restricta are directly correlated with PV development; however, M. sympodialis is more likely related to PV development in Chinese individuals. PMID:25177714

  14. An analysis of the Malassezia species distribution in the skin of patients with pityriasis versicolor in Chengdu, China.

    PubMed

    Xie, Zhen; Ran, Yuping; Zhang, Hao; Zhang, Min; Wan, Huiying; Li, Conghui

    2014-01-01

    Pityriasis versicolor (PV) is a common clinical problem associated with Malassezia species (Malassezia spp.). Controversies remain regarding the specific species involved in the development of PV. This study analyzed the difference in Malassezia spp. distribution in lesional and nonlesional skin in Chinese PV patients. A paired design was applied. Lesional and nonlesional scales from 24 cases were collected; real-time fluorescence quantitative PCR was used to detect 10 different Malassezia spp. In lesional skin, the highest detection rates were for M. globosa (95.8%), M. restricta (91.7%), and M. sympodialis (50.0%). In nonlesional skin, the highest detection rates were for M. globosa (87.5%), M. restricta (79.2%), and M. dermatis (33.3%). A significant difference in the detection rate was only found for M. sympodialis (50.8% versus 20.8%, P = 0.04). Compared with nonlesional skin, the amount of M. globosa, M. restricta, and M. sympodialis in lesional skin was significantly higher (3.8 ± 1.3,  2.5 ± 1.1, and 3.2 ± 1.6 times higher, resp.). The results of this study do not indicate that M. globosa and M. restricta are directly correlated with PV development; however, M. sympodialis is more likely related to PV development in Chinese individuals.

  15. Latest generation, wide-angle, high-definition colonoscopes increase adenoma detection rate.

    PubMed

    Adler, Andreas; Aminalai, Alireza; Aschenbeck, Jens; Drossel, Rolf; Mayr, Michael; Scheel, Mathias; Schröder, Andreas; Yenerim, Timur; Wiedenmann, Bertram; Gauger, Ulrich; Roll, Stephanie; Rösch, Thomas

    2012-02-01

    Improvements to endoscopy imaging technologies might improve detection rates of colorectal cancer and patient outcomes. We compared the accuracy of the latest generation of endoscopes with older generation models in detection of colorectal adenomas. We compared data from 2 prospective screening colonoscopy studies (the Berlin Colonoscopy Project 6); each study lasted approximately 6 months and included the same 6 colonoscopists, who worked in private practice. Participants in group 1 (n = 1256) were all examined by using the latest generation of wide-angle, high-definition colonoscopes that were manufactured by the same company. Individuals in group 2 (n = 1400) were examined by endoscopists who used routine equipment (a mixture of endoscopes from different companies; none of those used to examine group 1). The adenoma detection rate was calculated on the basis of the number of all adenomas/number of all patients. There were no differences in patient parameters or withdrawal time between groups (8.0 vs 8.2 minutes). The adenoma detection rate was significantly higher in group 1 (0.33) than in group 2 (0.27; P = .01); a greater number of patients with least 1 adenoma were identified in group 1 (22.1%) than in group 2 (18.2%; P = .01). A higher percentage of high-grade dysplastic adenomas were detected in group 1 (1.19%) than in group 2 (0.57%), but this difference was not statistically significant (P = .06). The latest generation of wide-angle, high-definition colonoscopes improves rates of adenoma detection by 22%, compared with mixed, older technology endoscopes used in routine private practice. These findings might affect definitions of quality control parameters for colonoscopy screening for colorectal cancer. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.

  16. Introduction of the colorectal cancer screening program: results from a single centre study.

    PubMed

    Vermeer, Nina C A; Bahadoer, Renu R; Bastiaannet, Esther; Holman, Fabian A; Meershoek-Klein Kranenbarg, Elma; Liefers, Gerrit-Jan; van de Velde, Cornelis J H; Peeters, Koen C M J

    2018-06-19

    In 2014, a national colorectal cancer (CRC) screening program was launched in the Netherlands. It is difficult to assess for the individual CRC patient whether the oncological benefits of surgery will outweigh the morbidity of the procedure, especially in early lesions. This study compares patient and tumour characteristics between screen-detected and non-screen-detected patients. Secondly, we present an overview of treatment options and clinical dilemmas when treating patients with early stage colorectal disease. Between January 2014 and December 2016, all patients with non-malignant polyps or CRC who were referred to the Department of Surgery of the Leiden University Medical Centre in the Netherlands were included. Baseline characteristics, type of treatment and short-term outcomes of patients with screen-detected and non-screen-detected colorectal tumours were compared. A total of 426 patients were included, of whom 240 (56.3%) were identified by screening. Non-screen-detected patients more often had comorbidity (p=0.03), the primary tumour was more often located in the rectum (p=0.001) and there was a higher rate of metastatic disease (p<0.001). Among 354 surgically treated patients, postoperative adverse events did not significantly differ between the two groups (p=0.38). Of 46 patients with T1 CRC in the endoscopic resection specimen, 23 underwent surgical resection of which only 30.4% had residual invasive disease at colectomy. Despite differences in comorbidity and stage, surgical outcome of patients with screen-detected tumours compared to non-screen-detected tumours was not significantly different. Considering its limited oncological benefits as well as the rate of adverse events, surgery for non-malignant polyps and T1 CRC should be considered carefully. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. Effectiveness of DIAGNOdent in Detecting Root Caries Without Dental Scaling Among Community-dwelling Elderly.

    PubMed

    Zhang, Wen; McGrath, Colman; Lo, Edward C M

    The purpose of this clinical research was to analyze the effectiveness of DIAGNOdent in detecting root caries without dental scaling. The status of 750 exposed, unfilled root surfaces was assessed by visual-tactile examination and DIAGNOdent before and after root scaling. The sensitivity and specificity of different cut-off DIAGNOdent values in diagnosing root caries with reference to visual-tactile criteria were evaluated on those root surfaces without visible plaque/calculus. The DIAGNOdent values from sound and carious root surfaces were compared using the nonparametric Mann-Whitney U-test. The level of statistical significance was set at 0.05. On root surfaces without plaque/calculus, significantly different (p < 0.05) DIAGNOdent readings were obtained from sound root surfaces (12.2 ± 11.1), active carious root surfaces (37.6 ± 31.7) and inactive carious root surfaces (20.9 ± 10.5) before scaling. On root surfaces with visible plaque, DIAGNOdent readings obtained from active carious root surfaces (29.6 ± 20.8) and inactive carious root surfaces (27.0 ± 7.2) were not statistically significantly different (p > 0.05). Furthermore, on root surfaces with visible calculus, all DIAGNOdent readings obtained from sound root surfaces were > 50, which might be misinterpreted as carious. After scaling, the DIAGNOdent readings obtained from sound root surfaces (8.1 ± 11.3), active carious root surfaces (37.9 ± 31.9) and inactive carious root surfaces (24.9 ± 11.5) presented significant differences (p < 0.05). A cut-off value between 10 and 15 yielded the highest combined sensitivity and specificity in detecting root caries on root surfaces without visible plaque/calculus before scaling, but the combined sensitivity and specificity are both around 70%. These findings suggest that on exposed, unfilled root surfaces without visible plaque/calculus, DIAGNOdent can be used as an adjunct to the visual-tactile criteria in detecting root-surface status without pre-treatment by dental scaling.

  18. Spectrotemporal Modulation Detection and Speech Perception by Cochlear Implant Users

    PubMed Central

    Won, Jong Ho; Moon, Il Joon; Jin, Sunhwa; Park, Heesung; Woo, Jihwan; Cho, Yang-Sun; Chung, Won-Ho; Hong, Sung Hwa

    2015-01-01

    Spectrotemporal modulation (STM) detection performance was examined for cochlear implant (CI) users. The test involved discriminating between an unmodulated steady noise and a modulated stimulus. The modulated stimulus presents frequency modulation patterns that change in frequency over time. In order to examine STM detection performance for different modulation conditions, two different temporal modulation rates (5 and 10 Hz) and three different spectral modulation densities (0.5, 1.0, and 2.0 cycles/octave) were employed, producing a total 6 different STM stimulus conditions. In order to explore how electric hearing constrains STM sensitivity for CI users differently from acoustic hearing, normal-hearing (NH) and hearing-impaired (HI) listeners were also tested on the same tasks. STM detection performance was best in NH subjects, followed by HI subjects. On average, CI subjects showed poorest performance, but some CI subjects showed high levels of STM detection performance that was comparable to acoustic hearing. Significant correlations were found between STM detection performance and speech identification performance in quiet and in noise. In order to understand the relative contribution of spectral and temporal modulation cues to speech perception abilities for CI users, spectral and temporal modulation detection was performed separately and related to STM detection and speech perception performance. The results suggest that that slow spectral modulation rather than slow temporal modulation may be important for determining speech perception capabilities for CI users. Lastly, test–retest reliability for STM detection was good with no learning. The present study demonstrates that STM detection may be a useful tool to evaluate the ability of CI sound processing strategies to deliver clinically pertinent acoustic modulation information. PMID:26485715

  19. Presence and distribution of chlorinated organic compounds in streambed sediments, new jersey

    USGS Publications Warehouse

    Stackelberg, P.E.

    1997-01-01

    Concentrations of 18 hydrophobic chlorinated organic compounds in streambed sediments from 100 sites throughout New Jersey were examined to determine (1) which compounds were detected most frequently, (2) whether detection frequencies differed among selected drainage basins, and (3) whether concentrations differed significantly among selected drainage basins. Twelve drainage basins across New Jersey that contain a range of land-use patterns and population densities were selected to represent various types and degrees of development. To ensure an adequate number of samples for statistical comparison among drainage basins, the 12 selected basins were consolidated into seven drainage areas on the basis of similarities in land- use patterns and population densities. Additionally, data for three classes of chlorinated organic compounds in streambed sediments from 255 sites throughout New Jersey were examined to determine whether the presence of these compounds in streambed sediments is related to the type and degree of development within the drainage area of each sampling site. Chlorinated organic compounds detected most frequently within the seven representative drainage areas were DDT, DDE, DDD, chlordane, dieldrin, and PCBs. DDT, DDE, and DDD, which were the most widely distributed organic compounds, were detected in about 60 to 100 percent of the samples from all drainage areas hut one (where the detection rate for these compounds was about 20 to 40 percent). Chlordane and dieldrin were detected in about 80 to 100 percent of samples from highly urbanized and populated drainage areas; detection frequencies for these compounds tended to be smaller in less developed and populated areas. PCBs were detected in about 40 to 85 percent of samples from all drainage areas; detection frequencies were highest in the most heavily developed and populated areas. Analysis of variance on rank-transformed organic compound concentrations normalized to sediment organic carbon content was used to evaluate differences in concentrations among the seven representative drainage areas. Chlordane and PCBs were the chlorinated organic compounds with the most highly elevated concentrations in streambed sediments across the State. Median normalized COncentrations of all six of the most frequently detected chlorinated organic compounds were highest in the most heavily urbanized and populated drainage area and lowest in the less populated, predominantly agricultural or forested areas. Concentrations of DDT and DDE, however, did not differ significantly among most of the drainage areas. Concentrations of DDD, chlordane, dieldrin, and PCBs differed significantly among drainage areas. The highest median normalized concentrations were found in samples from the most heavily urbanized and populated areas, and the lowest were in samples from the least developed, most heavily forested area. Logistic regression was used to examine relations between the presence of hydrophobic chlorinated organic compounds in streambed sediments at specified concentrations and variables that characterize the type and degree of development within the drainage areas of 255 sites across New Jersey. The explanatory variables found most useful for predicting the presence of chlorinated organic compounds in streambed sediments include total population and amounts (in square kilometers) of various land-use categories. Logistic regression equations were developed to identify significant relations between population and amounts of specific land-use categories within drainage areas and the probability of detecting chlorinated organic contaminants in streambed sediments. These relations can be used to assist in the identification of geographic regions of primary concern for contamination of bed sediments by chlorinated organic compounds across the State.

  20. Effect of chewing speed on the detection of a foreign object in food.

    PubMed

    Paphangkorakit, J; Ladsena, V; Rukyuttithamkul, T; Khamtad, T

    2016-03-01

    Accidentally biting hard on a piece of hard foreign object in food is among the causes of tooth fracturing and could be associated with oral sensibility. This study has investigated the effect of chewing speed on the ability to detect a foreign object in food in human. Fourteen healthy subjects were asked to randomly chew one of 10 cooked rice balls, five of which containing a foreign object made from a tiny uncooked rice grain, until they detected the rice grain. Each subject chewed the test foods both at 50 (slow) and 100 (fast) chews min(-1). The accuracy of detection and the number of chews before detection (CBD) were recorded and compared between the two chewing speeds using paired t-tests. The results showed that almost all subjects detected the foreign object by biting. The accuracy of detection was more than 90% and not significantly different between slow and fast chewing but the mean CBD in slow chewing (11·7 ± 1·3 chews) was significantly different from that in fast chewing (20·7 ± 1·9 chews; P < 0·001). The study showed that slow chewers required less number of chews before a foreign object in food could be detected and was, presumably, more effective in detecting the object compared to fast chewers. If each chew bears equal probability of teeth encountering the foreign object, slow chewing might also reduce the chance of accidentally biting hard on the foreign object and fracturing the tooth. © 2015 John Wiley & Sons Ltd.

  1. Radon Diffusion Measurement in Polyethylene based on Alpha Detection

    NASA Astrophysics Data System (ADS)

    Rau, Wolfgang

    2011-04-01

    We present a method to measure the diffusion of Radon in solid materials based on the alpha decay of the radon daughter products. In contrast to usual diffusion measurements which detect the radon that penetrates a thin barrier, we let the radon diffuse into the material and then measure the alpha decays of the radon daughter products in the material. We applied this method to regular and ultra high molecular weight poly ethylene and find diffusion lengths of order of mm as expected. However, the preliminary analysis shows significant differences between two different approaches we have chosen. These differences may be explained by the different experimental conditions.

  2. Detection of prostate cancer using magnetic resonance imaging/ultrasonography image-fusion targeted biopsy in African-American men.

    PubMed

    Shin, Toshitaka; Smyth, Thomas B; Ukimura, Osamu; Ahmadi, Nariman; de Castro Abreu, Andre Luis; Oishi, Masakatsu; Mimata, Hiromitsu; Gill, Inderbir S

    2017-08-01

    To assess the diagnostic yield of targeted prostate biopsy in African-American (A-A) men using image fusion of multi-parametric magnetic resonance imaging (mpMRI) with real-time transrectal ultrasonography (US). We retrospectively analysed 661 patients (117 A-A and 544 Caucasian) who had mpMRI before biopsy and then underwent MRI/US image-fusion targeted biopsy (FTB) between October 2012 and August 2015. The mpMRIs were reported on a 5-point Likert scale of suspicion. Clinically significant prostate cancer (CSPC) was defined as biopsy Gleason score ≥7. After controlling for age, prostate-specific antigen level and prostate volume, there were no significant differences between A-A and Caucasian men in the detection rate of overall cancer (35.0% vs 34.2%, P = 0.9) and CSPC (18.8% vs 21.7%, P = 0.3) with MRI/US FTB. There were no significant differences between the races in the location of dominant lesions on mpMRI, and in the proportion of 5-point Likert scoring. In A-A men, MRI/US FTB from the grade 4-5 lesions outperformed random biopsy in the detection rate of overall cancer (70.6% vs 37.2%, P = 0.003) and CSPC (52.9% vs 12.4%, P < 0.001). MRI/US FTB outperformed random biopsy in cancer core length (5.0 vs 2.4 mm, P = 0.001), in cancer rate per core (24.9% vs 6.8%, P < 0.001), and in efficiency for detecting one patient with CSPC (mean number of cores needed 13.3 vs 81.9, P < 0.001), respectively. Our key finding confirms a lack of racial difference in the detection rate of overall prostate cancers and CSPC with MRI/US FTB between A-A and Caucasian men. MRI/US FTB detected more CSPC using fewer cores compared with random biopsy. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  3. Expression of NF-κB and PTEN in osteosarcoma and its clinical significance

    PubMed Central

    Gong, Teng; Su, Xuetao; Xia, Qun; Wang, Jinggui; Kan, Shilian

    2017-01-01

    We investigated the role of nuclear factor-κB (NF-κB) and phosphatase and tensin homolog deleted in chromosome 10 (PTEN) in the pathogenesis of osteosarcoma and its relationship with prognosis. Immunohistochemical method was used to detect the expression of NF-κB and PTEN in osteosarcoma and adjacent tissues. RT-PCR was used to detect the expression of NF-κB and PTEN mRNA in osteosarcoma and adjacent tissues. Western blotting was used to detect the expression of NF-κB and PTEN in osteosarcoma and adjacent tissues and compare their differences. The expression of NF-κB and PTEN was detected in osteosarcoma and adjacent tissues. The positive rate of NF-κB was 75.3 and 32.9%, respectively; while the positive rate of PTEN was 67.1 and 90.4%, respectively. The positive expression of NF-κB and PTEN was statistically significant. There was a negative correlation between NF-κB and PTEN expression (r=−0.502, p<0.05). The positive and negative expression of NF-κB and PTEN was statistically significant for the five-year survival (p<0.05). At gene and protein level, osteosarcoma tissues had higher expression of NF-κB, and lower expression of PTEN, which was significantly different from the adjacent tissues. In osteosarcoma, NF-κB is highly expressed, but PTEN is expressed at low level, and the two are negatively correlated. This is of great significance for the early diagnosis of osteosarcoma and prognosis. PMID:29151913

  4. Assessment of image quality and low-contrast detectability in abdominal CT of obese patients: comparison of a novel integrated circuit with a conventional discrete circuit detector at different tube voltages.

    PubMed

    Euler, A; Heye, T; Kekelidze, M; Bongartz, G; Szucs-Farkas, Z; Sommer, C; Schmidt, B; Schindera, Sebastian T

    2015-03-01

    To compare image quality and low-contrast detectability of an integrated circuit (IC) detector in abdominal CT of obese patients with conventional detector technology at low tube voltages. A liver phantom with 45 lesions was placed in a water container to mimic an obese patient and examined on two different CT systems at 80, 100 and 120 kVp. The systems were equipped with either the IC or conventional detector. Image noise was measured, and the contrast-to-noise-ratio (CNR) was calculated. Low-contrast detectability was assessed independently by three radiologists. Radiation dose was estimated by the volume CT dose index (CTDIvol). The image noise was significantly lower, and the CNR was significantly higher with the IC detector at 80, 100 and 120 kVp, respectively (P = 0.023). The IC detector resulted in an increased lesion detection rate at 80 kVp (38.1 % vs. 17.2 %) and 100 kVp (57.0 % vs. 41.0 %). There was no difference in the detection rate between the IC detector at 100 kVp and the conventional detector at 120 kVp (57.0 % vs. 62.2 %). The CTDIvol at 80, 100 and 120 kVp measured 4.5-5.2, 7.3-7.9 and 9.8-10.2 mGy, respectively. The IC detector at 100 kVp resulted in similar low-contrast detectability compared to the conventional detector with a 120-kVp protocol at a radiation dose reduction of 37 %.

  5. Detecting and treating occlusal caries lesions: a cost-effectiveness analysis.

    PubMed

    Schwendicke, F; Stolpe, M; Meyer-Lueckel, H; Paris, S

    2015-02-01

    The health gains and costs resulting from using different caries detection strategies might not only depend on the accuracy of the used method but also the treatment emanating from its use in different populations. We compared combinations of visual-tactile, radiographic, or laser-fluorescence-based detection methods with 1 of 3 treatments (non-, micro-, and invasive treatment) initiated at different cutoffs (treating all or only dentinal lesions) in populations with low or high caries prevalence. A Markov model was constructed to follow an occlusal surface in a permanent molar in an initially 12-y-old male German patient over his lifetime. Prevalence data and transition probabilities were extracted from the literature, while validity parameters of different methods were synthesized or obtained from systematic reviews. Microsimulations were performed to analyze the model, assuming a German health care setting and a mixed public-private payer perspective. Radiographic and fluorescence-based methods led to more overtreatments, especially in populations with low prevalence. For the latter, combining visual-tactile or radiographic detection with microinvasive treatment retained teeth longest (mean 66 y) at lowest costs (329 and 332 Euro, respectively), while combining radiographic or fluorescence-based detections with invasive treatment was the least cost-effective (<60 y, >700 Euro). In populations with high prevalence, combining radiographic detection with microinvasive treatment was most cost-effective (63 y, 528 Euro), while sensitive detection methods combined with invasive treatments were again the least cost-effective (<59 y, >690 Euro). The suitability of detection methods differed significantly between populations, and the cost-effectiveness was greatly influenced by the treatment initiated after lesion detection. The accuracy of a detection method relative to a "gold standard" did not automatically convey into better health or reduced costs. Detection methods should be evaluated not only against their criterion validity but also the long-term effects resulting from their use in different populations. © International & American Associations for Dental Research 2014.

  6. [Arginase Level in Suspended Red Blood Cells Storaged for Different Time].

    PubMed

    Fan, Li-Ping; Huang, Hao-Bo; Wei, Shi-Jin; Fu, Dan-Hui; Zeng, Feng; Huang, Qing-Hua; Hong, Jin-Quan

    2015-10-01

    To explore the effect of storage time on arginase level, and the possible source of arginase in suspended red blood cells (RBC). The arginase and myeloperoxidase (MPO) levels in suspended RBC and control plasma were detected by ELISA. The free hemoglobin level in suspended RBC and control plasma were detected by colorimetric method. The relationship between arginase level, MPO level and free hemoglobin level in suspended RBC was analyzed by the related methods. The arginase and free hemoglobin levels in suspended RBC were higher than those in control plasma. Otherwise, MPO level was not significantly different between suspended RBC and control plasma. All of them did not increase along with prolonging of storage time. There was not a significant correlation between arginase level and free hemoglobin level in suspended RBC of different storage time (r = 0.03), but arginase level positively correlated with MPO level in the suspended RBC of different storage time (r = 0.76). The arginase level in suspended RBC storaged for different time increases significantly, but not along with prolonging of storage time. The main possible source of arginase in the suspended RBC is the residual white blood cell, especially neutrophils.

  7. Parasitic infections associated with malignancy and leprosy.

    PubMed

    Azab, M E; Mohamed, N H; Salem, S A; Safar, E H; Bebars, M A; Sabry, N M; Mohamed, M S

    1992-04-01

    Results of parasitic infections, as revealed by urine and stool examination was significant (P less than 0.05) in 43.3% of patients suffering from different malignant diseases and non significant (P greater than 0.05) in 29.3% of leprosy patients compared to 22% in control subjects. The most prevalent parasites were E. histolytica and G. lamblia. Cryptosporidium occysts were not detected. By stool examination and culture, S. stercoralis larvae were detected only in the malignancy group. The most common parasites occurring concomitantly were A. duodenale and S. stercoralis. By the IFAT, strongyloidiasis gave significantly higher positive results in the malignancy group than in the leprosy and control groups. IFAT for toxocariasis, showed highly significant positivity in the leprosy group and significantly positivity in the malignancy group. For toxoplasmosis, it showed highly significant positive results in both leprosy and malignancy groups. Eosinophilia was significantly more prominent among malignancy patients and insignificant among those with leprosy. Parasitic infection detected by urine and stool examination among patients with eosinophilia was found in 76% of the malignancy patients and in 66.7% of the leprosy patients.

  8. Cardiotoxicity of Freon among refrigeration services workers: comparative cross-sectional study

    PubMed Central

    2009-01-01

    Background Freon includes a number of gaseous, colorless chlorofluorocarbons. Although freon is generally considered to be a fluorocarbon of relatively low toxicity; significantly detrimental effects may occur upon over exposure. The purpose of the present study is to investigate whether occupational exposure to fluorocarbons can induce arterial hypertension, myocardial ischemia, cardiac arrhythmias, elevated levels of plasma lipids and renal dysfunction. Methods This comparative cross-sectional study was conducted at the cardiology clinic of the Suez Canal Authority Hospital (Egypt). The study included 23 apparently healthy male workers at the refrigeration services workshop who were exposed to fluorocarbons (FC 12 and FC 22) and 23 likewise apparently healthy male workers (unexposed), the control group. All the participants were interviewed using a pre-composed questionnaire and were subjected to a clinical examination and relevant laboratory investigations. Results There were no significant statistical differences between the groups studied regarding symptoms suggesting arterial hypertension and renal affection, although a significantly higher percentage of the studied refrigeration services workers had symptoms of arrhythmias. None of the workers had symptoms suggesting coronary artery disease. Clinical examination revealed that the refrigeration services workers had a significantly higher mean pulse rate compared to the controls, though no significant statistical differences were found in arterial blood pressure measurements between the two study groups. Exercise stress testing of the workers studied revealed normal heart reaction to the increased need for oxygen, while sinus tachycardia was detected in all the participants. The results of Holter monitoring revealed significant differences within subject and group regarding the number of abnormal beats detected throughout the day of monitoring (p < 0.001). There were no significant differences detected in the average heart rate during the monitoring period within subject or group. Most laboratory investigations revealed absence of significant statistical differences for lipid profile markers, serum electrolyte levels and glomerular lesion markers between the groups except for cholesterol and urinary β2-microglobulin (tubular lesion markers) levels which were significantly elevated in freon exposed workers. Conclusions Unprotected occupational exposure to chlorofluorocarbons can induce cardiotoxicity in the form of cardiac arrhythmias. The role of chlorofluorocarbons in inducing arterial hypertension and coronary artery diseases is unclear, although significantly elevated serum cholesterol and urinary β2-microglobulin levels raise a concern. PMID:19594908

  9. Low power and type II errors in recent ophthalmology research.

    PubMed

    Khan, Zainab; Milko, Jordan; Iqbal, Munir; Masri, Moness; Almeida, David R P

    2016-10-01

    To investigate the power of unpaired t tests in prospective, randomized controlled trials when these tests failed to detect a statistically significant difference and to determine the frequency of type II errors. Systematic review and meta-analysis. We examined all prospective, randomized controlled trials published between 2010 and 2012 in 4 major ophthalmology journals (Archives of Ophthalmology, British Journal of Ophthalmology, Ophthalmology, and American Journal of Ophthalmology). Studies that used unpaired t tests were included. Power was calculated using the number of subjects in each group, standard deviations, and α = 0.05. The difference between control and experimental means was set to be (1) 20% and (2) 50% of the absolute value of the control's initial conditions. Power and Precision version 4.0 software was used to carry out calculations. Finally, the proportion of articles with type II errors was calculated. β = 0.3 was set as the largest acceptable value for the probability of type II errors. In total, 280 articles were screened. Final analysis included 50 prospective, randomized controlled trials using unpaired t tests. The median power of tests to detect a 50% difference between means was 0.9 and was the same for all 4 journals regardless of the statistical significance of the test. The median power of tests to detect a 20% difference between means ranged from 0.26 to 0.9 for the 4 journals. The median power of these tests to detect a 50% and 20% difference between means was 0.9 and 0.5 for tests that did not achieve statistical significance. A total of 14% and 57% of articles with negative unpaired t tests contained results with β > 0.3 when power was calculated for differences between means of 50% and 20%, respectively. A large portion of studies demonstrate high probabilities of type II errors when detecting small differences between means. The power to detect small difference between means varies across journals. It is, therefore, worthwhile for authors to mention the minimum clinically important difference for individual studies. Journals can consider publishing statistical guidelines for authors to use. Day-to-day clinical decisions rely heavily on the evidence base formed by the plethora of studies available to clinicians. Prospective, randomized controlled clinical trials are highly regarded as a robust study and are used to make important clinical decisions that directly affect patient care. The quality of study designs and statistical methods in major clinical journals is improving overtime, 1 and researchers and journals are being more attentive to statistical methodologies incorporated by studies. The results of well-designed ophthalmic studies with robust methodologies, therefore, have the ability to modify the ways in which diseases are managed. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  10. Detection of Two TeV Shell-type Remnants at GeV Energies with FERMI LAT: HESS J1731-347 and SN 1006

    NASA Astrophysics Data System (ADS)

    Condon, B.; Lemoine-Goumard, M.; Acero, F.; Katagiri, H.

    2017-12-01

    We report the first high-significance GeV γ-ray detections of supernova remnants HESS J1731‑347 and SN 1006, both of which have been previously detected by imaging atmospheric Cherenkov Telescopes above 1 TeV. Using 8 years of Fermi-LAT Pass 8 data at energies between 1 GeV and 2 TeV, we detect emission at the position of HESS J1731‑347 with a significance of ∼ 5σ and a spectral index of {{Γ }}=1.66+/- {0.16}{stat}+/- {0.12}{syst}. The hardness of the index and the good connection with the TeV spectrum of HESS J1731‑347 support an association between the two sources. We also confirm the detection of SN 1006 at ∼ 6σ with a spectral index of {{Γ }}=1.79+/- {0.17}{stat}+/- {0.27}{syst}. The northeast (NE) and southwest (SW) limbs of SN 1006 were also fit separately, resulting in the detection of the NE region ({{Γ }}=1.47+/- {0.26}{stat}) and the non-detection of the SW region. The significance of different spectral components for the two limbs is 3.6σ , providing first indications of an asymmetry in the GeV γ-ray emission.

  11. Detection of circulating tumour cells in peripheral blood of patients with malignant pleural mesothelioma.

    PubMed

    Raphael, Jacques; Massard, Christophe; Gong, Inna Y; Farace, Françoise; Margery, Jacques; Billiot, Fanny; Hollebecque, Antoine; Besse, Benjamin; Soria, Jean-Charles; Planchard, David

    2015-01-01

    The independent prognostic value of Circulating Tumour Cells (CTC) level has been demonstrated in several solid tumours. There is currently few data on Malignant Pleural Mesothelioma (MPM) and CTC. We investigated whether the presence of CTC was correlated with prognosis factors and treatment efficacy. MPM patients (pts) were enrolled in a prospective monocentric study. CTC detection was made using the "CellSearch" assay. The correlation between the presence of CTC and worse prognosis factors was assessed using the X(2) test. Comparison of Overall Survival (OS) and Progression Free Survival (PFS) according to CTC detection was performed using the log-rank test. Twenty-seven MPM pts with a median follow-up of 4.2 months were included. CTC were detected in 44% of pts with a median level of 1.5. No significant correlation was observed between the presence of CTC and worse prognosis factors. Moreover, CTC detection was not a significant predictor of OS or PFS (p=0.155 and p=0.32 respectively). CTC were detected in a small cohort of MPM patients. We couldn't demonstrate a significant prognostic value or a difference in OS/PFS between CTC levels. Further analyses, validation studies and detection techniques are needed to establish their real clinical value in MPM.

  12. Infrared Skin Thermometry: Validating and Comparing Techniques to Detect Periwound Skin Infection.

    PubMed

    Mufti, Asfandyar; Somayaji, Ranjani; Coutts, Patricia; Sibbald, R Gary

    2018-01-01

    Diagnosis of wound infection can be challenging because it relies on a combination of clinical signs and symptoms that are often nonspecific. Increased periwound cutaneous temperature is a classic sign of deep and surrounding wound infection, and its quantitative measurement is one of the most reliable and valid clinical signs of deep and surrounding skin infection at the bedside. Skin surface temperature differences may be detected using commercially available noncontact infrared thermometers. However, techniques to detect temperature using noncontact infrared thermometers vary, and no studies have evaluated these methods. Two such measurement techniques include the "4-point" and "whole-wound" scanning methods. This study assessed the ability of different infrared thermometers using the aforementioned techniques to detect clinically meaningful differences in periwound cutaneous temperatures used in the diagnosis of wound infection. A prospective cohort study was conducted from 2015 to 2016 of consenting adult patients 18 years or older with an open wound attending a regional wound care clinic. One hundred patients with wounds underwent surface temperature measurement. Infection was not a specific inclusion criterion as the primary objective was to conduct a comparative assessment of infrared thermometry devices. Demographic data (age, height, weight, gender, and ethnicity) were also collected. Each wound was measured using 4 different noncontact infrared thermometers: Exergen DermaTemp 1001 (Exergen Corporation, Watertown, Massachusetts), Mastercraft Digital Temperature Reader (Mastercraft, Toronto, Ontario, Canada), Mastercool MSC52224-A (Mastercool Inc, Randolph, New Jersey), and Etekcity ETC-8250 Temperature Heat Pen (Etekcity, Anaheim, California). Data analysis was based on a comparison of 4 periwound skin surface temperature measurement differences (ΔT in degrees Fahrenheit) between the wound site and an equivalent contralateral control site. The primary outcome of the ability of each thermometer to detect a clinically significant difference in temperature was assessed with χ analysis. Paired t tests were conducted to compare the ΔT measurements of each specific thermometry device between the 2 measurement techniques. Pearson product moment correlation coefficients were calculated for the temperature ΔT for both measuring techniques for all devices to determine level of agreement. A 1-way analysis of variance was conducted to compare temperature measurements among the infrared thermometry devices. There was no significant difference in the ability of each thermometer to detect a clinically meaningful difference of 3° F by either the 4-point (P = .10) or whole-wound techniques (P = .67). When a definition of 4° F was used, results were similar (4-point, P = .15; whole wound, P = .20). Comparisons among devices and techniques showed strong correlations (>0.80). Etekcity ETC-8250 and the 4-point measurement compared with the Exergen device using the whole-wound technique had a correlation coefficient of 0.72. Spearman ρ demonstrated a similarly high degree of correlation between techniques and devices, and only the Etekcity ETC-8250 device had a coefficient of 0.71 to 0.90 when compared with others. Paired t testing for each thermometry device comparing measurement techniques for raw temperatures ΔT demonstrated no significant difference (P > .05). No statistical differences among the ΔT values for the 3 different thermometers were noted when using the whole-wound method (P = .095). Similarly, no significant differences among the ΔT values were noted for the 4 different thermometers when using the 4-point method (P = .10). The results of this study demonstrate that both the 4-point and whole-wound methods of temperature acquisition using cost-efficient infrared thermometers provide accurate and similar results in clinical wound care settings.

  13. Stream Water, Carbon and Total Nitrogen Load Responses to a Simulated Emerald Ash Borer Infestation in Black Ash Dominated Headwater Wetlands

    NASA Astrophysics Data System (ADS)

    Van Grinsven, M. J.; Shannon, J.; Noh, N. J.; Kane, E. S.; Bolton, N. W.; Davis, J.; Wagenbrenner, J.; Sebestyen, S. D.; Kolka, R.; Pypker, T. G.

    2017-12-01

    The rapid and extensive expansion of emerald ash borer (EAB) is considered an important ecological and economic disturbance, and will likely affect critical ecosystem services associated with black ash wetlands. It is unknown how EAB-induced disturbance in wetlands dominated with black ash will impact stream water, dissolved organic carbon (DOC) and total dissolved nitrogen (TDN) export dynamics. We hypothesized that loads of water, DOC and TDN exported from black ash wetlands would be elevated following an EAB-induced disturbance. Stream water, DOC and TDN loads exiting two black ash wetlands in headwater watersheds in Michigan were quantified over a four-year period, and were combined with wetland soil temperature and soil decomposition rate monitoring to better understand the biogeochemical implications of an EAB-induced disturbance. After a two-year baseline monitoring period, an EAB disturbance was simulated by felling (ash-cut) all black ash trees with diameters greater than 2.5-cm in one wetland. When compared to the unaltered control, stream water DOC and TDN concentrations exiting the ash-cut wetland were significantly larger by 39% and 38%, respectively during the post-treatment study period. The significantly elevated DOC and TDN concentrations were likely associated with the higher soil temperatures and increased rates of soil decomposition detected in the ash-cut site during the post-treatment period. No significant mean daily stream discharge differences were detected between treatments during the pre-treatment period, however the 0.46 mm d-1 mean daily stream discharge exiting the ash-cut wetland was significantly smaller than the 1.07 mm d-1 exiting the unaltered control during the post-treatment study period. The significantly smaller daily stream discharge in the ash-cut site likely contributed to the fact no significant differences between treatments for either mean daily DOC loads or TDN loads were detected during the post-treatment period, despite the detection of significantly higher DOC and TDN concentrations. Examination of seasonal stream water, DOC and TDN export dynamics revealed the relative magnitudes of EAB-induced impacts were not evenly distributed throughout the year, and these differences have distinct seasonal implications for downstream waterbodies.

  14. A retrospective analysis of preoperative staging modalities for oral squamous cell carcinoma.

    PubMed

    Kähling, Ch; Langguth, T; Roller, F; Kroll, T; Krombach, G; Knitschke, M; Streckbein, Ph; Howaldt, H P; Wilbrand, J-F

    2016-12-01

    An accurate preoperative assessment of cervical lymph node status is a prerequisite for individually tailored cancer therapies in patients with oral squamous cell carcinoma. The detection of malignant spread and its treatment crucially influence the prognosis. The aim of the present study was to analyze the different staging modalities used among patients with a diagnosis of primary oral squamous cell carcinoma between 2008 and 2015. An analysis of preoperative staging findings, collected by clinical palpation, ultrasound, and computed tomography (CT), was performed. The results obtained were compared with the results of the final histopathological findings of the neck dissection specimens. A statistical analysis using McNemar's test was performed. The sensitivity of CT for the detection of malignant cervical tumor spread was 74.5%. The ultrasound obtained a sensitivity of 60.8%. Both CT and ultrasound demonstrated significantly enhanced sensitivity compared to the clinical palpation with a sensitivity of 37.1%. No significant difference was observed between CT and ultrasound. A combination of different staging modalities increased the sensitivity significantly compared with ultrasound staging alone. No significant difference in sensitivity was found between the combined use of different staging modalities and CT staging alone. The highest sensitivity, of 80.0%, was obtained by a combination of all three staging modalities: clinical palpation, ultrasound and CT. The present study indicates that CT has an essential role in the preoperative staging of patients with oral squamous cell carcinoma. Its use not only significantly increases the sensitivity of cervical lymph node metastasis detection but also offers a preoperative assessment of local tumor spread and resection borders. An additional non-invasive cervical lymph node examination increases the sensitivity of the tumor staging process and reduces the risk of occult metastasis. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Comparative study on gastrointestinal microbiota of eight fish species with different feeding habits.

    PubMed

    Li, J; Ni, J; Li, J; Wang, C; Li, X; Wu, S; Zhang, T; Yu, Y; Yan, Q

    2014-12-01

    To reveal the effects of fish genotype, feeding habits and serum physiological index on the composition of gastrointestinal microbiota, eight fish species with four different feeding habits were investigated. The V1 to V3 regions of 16S rRNA gene were analysed by high-throughput sequencing (454 platform) to compare the gut microbiota of different fish species. A total of 551 995 high-quality sequences with an average length of 463 bp were obtained from the 48 samples. No significant difference was observed among the detected sequences obtained from fishes with different feeding habits (One-way anova, F = 1·003, P = 0·400), but the number of OTUs among different feeding habits was significantly different (One-way anova, F = 7·564, P < 0·001). Additionally, significant correlations were detected between the fish genotype and microbial composition (partial Mantel test, all P values = 0·001) in the stomach, foregut and hindgut. Moreover, different core intestinal microbiota was also noticed in the eight fish species with different feeding habits. Feeding habits and genotype clearly affected the gastrointestinal microbiota of fish. Moreover, the evolutionary process shaped the serum physiological indexes of fish. This study provided much important information for developing commercial fish feeds. © 2014 The Society for Applied Microbiology.

  16. Detection and typing of human papillomavirus DNA in penile carcinoma: evidence for multiple independent pathways of penile carcinogenesis.

    PubMed

    Rubin, M A; Kleter, B; Zhou, M; Ayala, G; Cubilla, A L; Quint, W G; Pirog, E C

    2001-10-01

    To clarify the role of human papillomavirus (HPV) in penile cancer we evaluated the prevalence of HPV DNA in different histological subtypes of penile carcinoma, dysplasia, and condyloma using a novel, sensitive SPF10 HPV polymerase chain reaction assay and a novel genotyping line probe assay, allowing simultaneous identification of 25 different HPV types. Formalin-fixed, paraffin-embedded tissue samples were collected from the United States and Paraguay. HPV DNA was detected in 42% cases of penile carcinoma, 90% cases of dysplasia, and 100% cases of condyloma. There were significant differences in HPV prevalence in different histological cancer subtypes. Although keratinizing squamous cell carcinoma and verrucous carcinoma were positive for HPV DNA in only 34.9 and 33.3% of cases, respectively, HPV DNA was detected in 80% of basaloid and 100% of warty tumor subtypes. There was no significant difference in HPV prevalence between cases from Paraguay and the United States. In conclusion, the overall prevalence of HPV DNA in penile carcinoma (42%) is lower than that in cervical carcinoma (approximately 100%) and similar to vulvar carcinoma (approximately 50%). In addition, specific histological subtypes of penile cancer--basaloid and warty--are consistently associated with HPV, however, only a subset of keratinizing and verrucous penile carcinomas is positive for HPV DNA, and thus these two tumor groups seem to develop along different pathogenetic pathways.

  17. A comparison of FibroMeter™ NAFLD Score, NAFLD fibrosis score, and transient elastography as noninvasive diagnostic tools for hepatic fibrosis in patients with biopsy-proven non-alcoholic fatty liver disease.

    PubMed

    Aykut, Umut Emre; Akyuz, Umit; Yesil, Atakan; Eren, Fatih; Gerin, Fatma; Ergelen, Rabia; Celikel, Cigdem Ataizi; Yilmaz, Yusuf

    2014-11-01

    Noninvasive markers that purport to distinguish patients with non-alcoholic fatty liver disease (NAFLD) with fibrosis from those without must be evaluated rigorously for their classification accuracy. Herein, we seek to compare the diagnostic performances of three different noninvasive methods (FibroMeter™ NAFLD score, NAFLD Fibrosis score (NFSA), and Transient Elastrography [TE]) for the detection of liver fibrosis in NAFLD patients. A total of 88 patients with biopsy-proven NAFLD were included. The Kleiner system was used for grading fibrosis in liver biopsies. The FibroMeter™ NAFLD score was determined using a proprietary algorithm (regression score). The NFSA score was calculated based on age, hyperglycemia, body mass index, platelets, albumin and serum aminotransferase levels. TE was performed using the Fibroscan apparatus. The sensitivities/specificities for the FibroMeter™ NAFLD score, NFSA, and TE for the diagnosis of significant fibrosis (F2 + F3 + F4 fibrosis) were 38.6%/86.4%, 52.3%/88.6%, and 75.0%/93.2%, respectively. The areas under the receiver operating characteristic curves of TE were significantly higher than those of both the FibroMeter™ NAFLD score and NFSA. No significant differences were found between the FibroMeter™ NAFLD score and NFSA for the detection of significant and severe fibrosis, although the diagnostic performance of the FibroMeter™ NAFLD score was higher than that of the NFSA score for cirrhosis. In summary, TE showed the best diagnostic performance for the noninvasive assessment of liver fibrosis in NAFLD patients. The diagnostic performances of the FibroMeter™ NAFLD score and NFSA did not differ significantly for the detection of both significant and severe fibrosis.

  18. Automated Nucleic Acid Extraction Systems for Detecting Cytomegalovirus and Epstein-Barr Virus Using Real-Time PCR: A Comparison Study Between the QIAsymphony RGQ and QIAcube Systems.

    PubMed

    Kim, Hanah; Hur, Mina; Kim, Ji Young; Moon, Hee Won; Yun, Yeo Min; Cho, Hyun Chan

    2017-03-01

    Cytomegalovirus (CMV) and Epstein-Barr virus (EBV) are increasingly important in immunocompromised patients. Nucleic acid extraction methods could affect the results of viral nucleic acid amplification tests. We compared two automated nucleic acid extraction systems for detecting CMV and EBV using real-time PCR assays. One hundred and fifty-three whole blood (WB) samples were tested for CMV detection, and 117 WB samples were tested for EBV detection. Viral nucleic acid was extracted in parallel by using QIAsymphony RGQ and QIAcube (Qiagen GmbH, Germany), and real-time PCR assays for CMV and EBV were performed with a Rotor-Gene Q real-time PCR cycler (Qiagen). Detection rates for CMV and EBV were compared, and agreements between the two systems were analyzed. The detection rate of CMV and EBV differed significantly between the QIAsymphony RGQ and QIAcube systems (CMV, 59.5% [91/153] vs 43.8% [67/153], P=0.0005; EBV, 59.0% [69/117] vs 42.7% [50/117], P=0.0008). The two systems showed moderate agreement for CMV and EBV detection (kappa=0.43 and 0.52, respectively). QIAsymphony RGQ showed a negligible correlation with QIAcube for quantitative EBV detection. QIAcube exhibited EBV PCR inhibition in 23.9% (28/117) of samples. Automated nucleic acid extraction systems have different performances and significantly affect the detection of viral pathogens. The QIAsymphony RGQ system appears to be superior to the QIAcube system for detecting CMV and EBV. A suitable sample preparation system should be considered for optimized nucleic acid amplification in clinical laboratories.

  19. Prevalence of Cryptosporidium spp., Enterocytozoon bieneusi, Encephalitozoon spp. and Giardia intestinalis in Wild, Semi-Wild and Captive Orangutans (Pongo abelii and Pongo pygmaeus) on Sumatra and Borneo, Indonesia

    PubMed Central

    Mynářová, Anna; Foitová, Ivona; Kváč, Martin; Květoňová, Dana; Rost, Michael; Morrogh-Bernard, Helen; Nurcahyo, Wisnu; Nguyen, Cathleen; Supriyadi, Supriyadi; Sak, Bohumil

    2016-01-01

    Background Orangutans are critically endangered primarily due to loss and fragmentation of their natural habitat. This could bring them into closer contact with humans and increase the risk of zoonotic pathogen transmission. Aims To describe the prevalence and diversity of Cryptosporidium spp., microsporidia and Giardia intestinalis in orangutans at seven sites on Sumatra and Kalimantan, and to evaluate the impact of orangutans’ habituation and location on the occurrence of these zoonotic protists. Result The overall prevalence of parasites in 298 examined animals was 11.1%. The most prevalent microsporidia was Encephalitozoon cuniculi genotype II, found in 21 animals (7.0%). Enterocytozoon bieneusi genotype D (n = 5) and novel genotype Pongo 2 were detected only in six individuals (2.0%). To the best of our knowledge, this is the first report of these parasites in orangutans. Eight animals were positive for Cryptosporidium spp. (2.7%), including C. parvum (n = 2) and C. muris (n = 6). Giardia intestinalis assemblage B, subtype MB6, was identified in a single individual. While no significant differences between the different human contact level groups (p = 0.479–0.670) or between the different islands (p = 0.992) were reported in case of E. bieneusi or E. cuniculi, Cryptosporidium spp. was significantly less frequently detected in wild individuals (p < 2×10−16) and was significantly more prevalent in orangutans on Kalimantan than on Sumatra (p < 2×10−16). Conclusion Our results revealed that wild orangutans are significantly less frequently infected by Cryptosporidium spp. than captive and semi-wild animals. In addition, this parasite was more frequently detected at localities on Kalimantan. In contrast, we did not detect any significant difference in the prevalence of microsporidia between the studied groups of animals. The sources and transmission modes of infections were not determined, as this would require repeated sampling of individuals, examination of water sources, and sampling of humans and animals sharing the habitat with orangutans. PMID:27031241

  20. An Algorithm for Pedestrian Detection in Multispectral Image Sequences

    NASA Astrophysics Data System (ADS)

    Kniaz, V. V.; Fedorenko, V. V.

    2017-05-01

    The growing interest for self-driving cars provides a demand for scene understanding and obstacle detection algorithms. One of the most challenging problems in this field is the problem of pedestrian detection. Main difficulties arise from a diverse appearances of pedestrians. Poor visibility conditions such as fog and low light conditions also significantly decrease the quality of pedestrian detection. This paper presents a new optical flow based algorithm BipedDetet that provides robust pedestrian detection on a single-borad computer. The algorithm is based on the idea of simplified Kalman filtering suitable for realization on modern single-board computers. To detect a pedestrian a synthetic optical flow of the scene without pedestrians is generated using slanted-plane model. The estimate of a real optical flow is generated using a multispectral image sequence. The difference of the synthetic optical flow and the real optical flow provides the optical flow induced by pedestrians. The final detection of pedestrians is done by the segmentation of the difference of optical flows. To evaluate the BipedDetect algorithm a multispectral dataset was collected using a mobile robot.

  1. Too exhausted to see the truth: ego depletion and the ability to detect deception.

    PubMed

    Reinhard, Marc-André; Scharmach, Martin; Stahlberg, Dagmar

    2013-12-01

    In two experiments, recent findings showing the detrimental role of regulatory depletion in decision making are extended to the field of deception detection. In both experiments, the state of ego depletion was induced by having judges inhibit versus non-inhibit a dominant response while transcribing a text. Subsequently they judged true or deceptive messages of different stimulus persons with regard to their truthfulness. In both experiments, ego-depleted judges scored significantly lower on detection accuracy than control judges. Signal detection measures showed that this effect was not due to differences in judgmental bias between the two conditions. In Experiment 2, it was shown that the lower detection accuracy in the state of ego depletion was due to a feeling of difficulty of relying on verbal content information. Practical implications of the current findings are discussed. © 2012 The British Psychological Society.

  2. Development of detection and recognition of orientation of geometric and real figures.

    PubMed

    Stein, N L; Mandler, J M

    1975-06-01

    Black and white kindergarten and second-grade children were tested for accuracy of detection and recognition of orientation and location changes in pictures of real-world and geometric figures. No differences were found in accuracy of recognition between the 2 kinds of pictures, but patterns of verbalization differed on specific transformations. Although differences in accuracy were found between kindergarten and second grade on an initial recognition task, practice on a matching-to-sample task eliminated differences on a second recognition task. Few ethnic differences were found on accuracy of recognition, but significant differences were found in amount of verbal output on specific transformations. For both groups, mention of orientation changes was markedly reduced when location changes were present.

  3. The influence of thermal biology on road mortality risk in snakes.

    PubMed

    Mccardle, Logan D; Fontenot, Clifford L

    2016-02-01

    Road mortality is a significant threat to terrestrial vertebrates in many areas, and the novel thermal environment of black-topped roads may represent ecological traps for some species and demographic groups. We investigated the relationship between ambient temperature and on-road detection in a snake assemblage in southeastern Louisiana by comparing observations of live snakes on a black-topped road, across measurements of air temperature and road temperature on survey days. Analyses indicated on-road detection of snakes was significantly influenced by ambient temperature conditions for five snake species. Additionally, road temperatures, and the difference between air and road temperatures, were strong drivers of on-road snake detections. Permutation analysis methods revealed that significant temperature related group (species or sex) structure exists in occurrences of snakes on the roadway, and that road temperature was the strongest driver of species differences. We also compared how air and road temperatures affected occurrence on the road between sexes in the colubrid snakes Nerodia fasciata, Nerodia cyclopion, Thamnophis proximus, and Pantherophis obsoletus. Males and females of the viviparous species N. fasciata, N. cyclopion, and T. proximus diverged significantly in temperature preferences, with females found under warmer conditions, while males and females of the oviparous species P. obsoletus did not. Road temperature was also the strongest driver of differences between sexes. Our results indicate that black-topped roads are an ecological trap that is heavily influenced by sex, reproductive condition, and species specific thermoregulatory requirements, particularly for viviparous species. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. A comparison of Kodak Ultraspeed and Ektaspeed plus dental X-ray films for the detection of dental caries.

    PubMed

    Wong, A; Monsour, P A; Moule, A J; Basford, K E

    2002-03-01

    Using the fastest dental X-ray film available is an easy way of reducing exposure to ionizing radiation. However, the diagnostic ability of fast films for the detection of proximal surface caries must be demonstrated before these films will become universally accepted. Extracted premolar and molar teeth were arranged to simulate a bitewing examination and radiographed using Ultraspeed and Ektaspeed Plus dental X-ray films. Three different exposure times were used for each film type. Six general dentists were used to determine the presence and depth of the decay in the proximal surfaces of the teeth radiographed. The actual extent of the decay in the teeth was determined by sectioning the teeth and examining them under a microscope. There was no significant difference between the two films for the mean correct diagnosis. However, there was a significant difference between the means for the three exposure times used for Ultraspeed film. The practitioners used were not consistent in their ability to make a correct diagnosis, or for the film for which they got the highest correct diagnosis. Ektaspeed Plus dental X-ray film is just as reliable as Ultraspeed dental X-ray film for the detection of proximal surface decay. The effect of underexposure was significant for Ultraspeed, but not for Ektaspeed Plus. Patient exposure can be reduced significantly with no loss of diagnostic ability by changing from Ultraspeed X-ray film to Ektaspeed Plus X-ray film.

  5. Evaluation of an integrated graphical display to promote acute change detection in ICU patients

    PubMed Central

    Anders, Shilo; Albert, Robert; Miller, Anne; Weinger, Matthew B.; Doig, Alexa K.; Behrens, Michael; Agutter, Jim

    2012-01-01

    Objective The purpose of this study was to evaluate ICU nurses’ ability to detect patient change using an integrated graphical information display (IGID) versus a conventional tabular ICU patient information display (i.e. electronic chart). Design Using participants from two different sites, we conducted a repeated measures simulator-based experiment to assess ICU nurses’ ability to detect abnormal patient variables using a novel IGID versus a conventional tabular information display. Patient scenarios and display presentations were fully counterbalanced. Measurements We measured percent correct detection of abnormal patient variables, nurses’ perceived workload (NASA-TLX), and display usability ratings. Results 32 ICU nurses (87% female, median age of 29 years, and median ICU experience of 2.5 years) using the IGID detected more abnormal variables compared to the tabular display [F (1,119)=13.0, p < 0.05]. There was a significant main effect of site [F (1, 119)=14.2], with development site participants doing better. There were no significant differences in nurses’ perceived workload. The IGID display was rated as more usable than the conventional display, [F (1, 60)=31.7]. Conclusion Overall, nurses reported more important physiological information with the novel IGID than tabular display. Moreover, the finding of site differences may reflect local influences in work practice and involvement in iterative display design methodology. Information displays developed using user-centered design should accommodate the full diversity of the intended user population across use sites. PMID:22534099

  6. A Vibration-Based Approach for Stator Winding Fault Diagnosis of Induction Motors: Application of Envelope Analysis

    DTIC Science & Technology

    2014-10-02

    takes it either as auxiliary to magnetic flux, or is not able to detect the winding faults unless severity is already quite significant. This paper...different loads, speeds and severity levels. The experimental results show that the proposed method was able to detect inter-turn faults in the...maintenance strategy requires the technologies of: (a) on- line condition monitoring, (b) fault detection and diagnosis, and (c) prognostics. Figure 1

  7. Prospective multi-center study of an automatic online seizure detection system for epilepsy monitoring units.

    PubMed

    Fürbass, F; Ossenblok, P; Hartmann, M; Perko, H; Skupch, A M; Lindinger, G; Elezi, L; Pataraia, E; Colon, A J; Baumgartner, C; Kluge, T

    2015-06-01

    A method for automatic detection of epileptic seizures in long-term scalp-EEG recordings called EpiScan will be presented. EpiScan is used as alarm device to notify medical staff of epilepsy monitoring units (EMUs) in case of a seizure. A prospective multi-center study was performed in three EMUs including 205 patients. A comparison between EpiScan and the Persyst seizure detector on the prospective data will be presented. In addition, the detection results of EpiScan on retrospective EEG data of 310 patients and the public available CHB-MIT dataset will be shown. A detection sensitivity of 81% was reached for unequivocal electrographic seizures with false alarm rate of only 7 per day. No statistical significant differences in the detection sensitivities could be found between the centers. The comparison to the Persyst seizure detector showed a lower false alarm rate of EpiScan but the difference was not of statistical significance. The automatic seizure detection method EpiScan showed high sensitivity and low false alarm rate in a prospective multi-center study on a large number of patients. The application as seizure alarm device in EMUs becomes feasible and will raise the efficiency of video-EEG monitoring and the safety levels of patients. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Effect of Metal Artifacts on Detection of Vertical Root Fractures Using Two Cone Beam Computed Tomography Systems.

    PubMed

    Safi, Yaser; Aghdasi, Mohammad Mehdi; Ezoddini-Ardakani, Fatemeh; Beiraghi, Samira; Vasegh, Zahra

    2015-01-01

    Vertical root fracture (VRF) is common in endodontically treated teeth. Conventional and digital radiographies have limitations for detection of VRFs. Cone-beam computed tomography (CBCT) offers greater detection accuracy of VRFs in comparison with conventional radiography. This study compared the effects of metal artifacts on detection of VRFs by using two CBCT systems. Eighty extracted premolars were selected and sectioned at the level of the cemento enamel junction (CEJ). After preparation, root canals were filled with gutta-percha. Subsequently, two thirds of the root fillings were removed for post space preparation and a custom-made post was cemented into each canal. The teeth were randomly divided into two groups (n=40). In the test group, root fracture was created with Instron universal testing machine. The control teeth remained intact. CBCT scans of all teeth were obtained with either New Tom VGI or Soredex Scanora 3D. Three observers analyzed the images for detection of VRF. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for VRF detection and percentage of probable cases were calculated for each imaging system and compared using non-parametric tests considering the non-normal distribution of data. The inter-observer reproducibility was calculated using the weighted kappa coefficient. There were no statistically significant differences in sensitivity, specificity, PPV and NPV between the two CBCT systems. The effect of metal artifacts on VRF detection was not significantly different between the two CBCT systems.

  9. Comparative elemental analysis of fine particulate matter (PM2.5) from industrial and residential areas in Greater Cairo-Egypt by means of a multi-secondary target energy dispersive X-ray fluorescence spectrometer

    NASA Astrophysics Data System (ADS)

    Shaltout, Abdallah A.; Hassan, Salwa K.; Karydas, Andreas G.; Zaki, Z. I.; Mostafa, Nasser Y.; Kregsamer, Peter; Wobrauschek, Peter; Streli, Christina

    2018-07-01

    Fine aerosol particles with aerodynamic diameter equal or <2.5 μm (PM2.5) have been collected from industrial and residential areas of Greater Cairo, Egypt during two different seasons namely; autumn 2014 and winter 2014/2015. Energy dispersive X-ray fluorescence (EDXRF) analysis utilizing polarization geometry and three different secondary targets (CaF2, Ge, and Mo) was employed for the quantitative analysis of eighteen (18) elements in PM2.5 samples. Light elements like Na and Mg was possible to be quantified, whereas detection limits in the range of few ng m-3 were attained for the most of the detected elements. Although, the average mass concentrations of the PM2.5 collected from the residential area (27 ± 7 μg m-3) is close to the annual mean limit value, a significant number of the collected samples (33%) presented higher average mass concentrations. For the industrial location, the average mass concentration is equal to 55 ± 19 μg m-3, exceeded twofold the annual mean limit value of the European Commission. Remarkably high elemental concentrations were determined for the most of the detected elements from the industrial area samples, clearly indicating the significant influence of anthropogenic activities. The present optimized EDXRF analysis offered significantly improved analytical range and limits of detection with respect to previous similar studies, thus enhancing our knowledge and understanding on the contribution of different pollution sources.

  10. Experimental research on crack detection in pipes based on Fiber Bragg grating

    NASA Astrophysics Data System (ADS)

    Cai, Lin; Wei, Qin; Yu, Zhaoxiang; Lu, Ming; Li, Xiaowei

    2017-11-01

    Crack is one of the primary faults in pipes, and its detection is a significant measure to ensure the safety of pipes. The feasibility of circumferential crack detection in pipes on the basis of fiber Bragg grating (FBG) detection technology is discussed through experimental research. Crack is formed on the surface of a metal pipe, the circumferential length of crack is one index of the damage degree. In the experiments, both electronic vibration sensor and FBG strain sensors are used to collect response signals of impulse excitation in different damage degrees. Furthermore, the characteristics of damage detection are analysed in both frequency domain and time domain. First, the natural frequencies are compared between practical and simulated results in different damage degrees of pipes; second, the multi-fractal detrended fluctuation analysis (MFDFA) is applied to acquire the singular values α as the characteristic parameter. The experimental results indicate that FBG strain sensors can perceive the impulse response of the pipe and change in different damage degrees effectively, like the vibration sensor. And both the natural frequency and the singular value are sensitive to increasing length of crack, they are able to distinguish different degrees of crack on the pipe.

  11. It's the deceiver, not the receiver: No individual differences when detecting deception in a foreign and a native language.

    PubMed

    Law, Marvin K H; Jackson, Simon A; Aidman, Eugene; Geiger, Mattis; Olderbak, Sally; Kleitman, Sabina

    2018-01-01

    Individual differences in lie detection remain poorly understood. Bond and DePaulo's meta-analysis examined judges (receivers) who were ascertaining lies from truths and senders (deceiver) who told these lies and truths. Bond and DePaulo found that the accuracy of detecting deception depended more on the characteristics of senders rather than the judges' ability to detect lies/truths. However, for many studies in this meta-analysis, judges could hear and understand senders. This made language comprehension a potential confound. This paper presents the results of two studies. Extending previous work, in Study 1, we removed language comprehension as a potential confound by having English-speakers (N = 126, mean age = 19.86) judge the veracity of German speakers (n = 12) in a lie detection task. The twelve lie-detection stimuli included emotional and non-emotional content, and were presented in three modalities-audio only, video only, and audio and video together. The intelligence (General, Auditory, Emotional) and personality (Dark Triads and Big 6) of participants was also assessed. In Study 2, a native German-speaking sample (N = 117, mean age = 29.10) were also tested on a similar lie detection task to provide a control condition. Despite significantly extending research design and the selection of constructs employed to capture individual differences, both studies replicated Bond and DePaulo's findings. The results of Study1 indicated that removing language comprehension did not amplify individual differences in judge's ability to ascertain lies from truths. Study 2 replicated these results confirming a lack of individual differences in judge's ability to detect lies. The results of both studies suggest that Sender (deceiver) characteristics exerted a stronger influence on the outcomes of lie detection than the judge's attributes.

  12. Anxiety sensitivity, body vigilance and fear of pain.

    PubMed

    Esteve, M Rosa; Camacho, Laura

    2008-06-01

    The aim of the present study was to investigate the role of anxiety sensitivity (AS) as a factor relevant to pain and pain persistence. Two studies were conducted to examine the relationship between AS, body vigilance and the experience of pain in non-clinical samples. Study 1 investigated the relationship between AS and body vigilance that was operationalized by the detection latency for innocuous electrical stimuli; trait anxiety and neuroticism were also included as covariates. Results indicated that the high AS group (N=69) presented shorter detection latency than the low AS group (N=70); neuroticism and trait anxiety did not have significant effects on detection latency. Using another sample, Study 2 investigated the relationship between AS, body vigilance, pain tolerance, catastrophizing, and self-reported distress and pain during a cold pressor task. Neuroticism, trait anxiety and fear of pain were included as covariates. Results showed significant differences between high- (N=66) and low- (N=69) AS groups in body vigilance, catastrophizing and tolerance. The covariates neuroticism, trait anxiety and fear of pain did not have any significant effects. No significant differences were found in pain and distress ratings. Results from both studies support the importance of AS in body vigilance and the experience of pain. The theoretical, preventive and clinical implications of these findings are discussed.

  13. Dental Hygiene Faculty Calibration Using Two Accepted Standards for Calculus Detection: A Pilot Study.

    PubMed

    Santiago, Lisa J; Freudenthal, Jacqueline J; Peterson, Teri; Bowen, Denise M

    2016-08-01

    Faculty calibration studies for calculus detection use two different standards for examiner evaluation, yet the only therapeutic modality that can be used for nonsurgical periodontal treatment is scaling/root debridement or planing. In this study, a pretest-posttest design was used to assess the feasibility of faculty calibration for calculus detection using two accepted standards: that established by the Central Regional Dental Testing Service, Inc. (CRDTS; readily detectible calculus) and the gold standard for scaling/root debridement (root roughness). Four clinical dental hygiene faculty members out of five possible participants at Halifax Community College agreed to participate. The participants explored calculus on the 16 assigned teeth (64 surfaces) of four patients. Calculus detection scores were calculated before and after training. Kappa averages using CRDTS criteria were 0.561 at pretest and 0.631 at posttest. Kappa scores using the scaling/root debridement or planing standard were 0.152 at pretest and 0.271 at posttest. The scores indicated improvement from moderate (Kappa=0.41-0.60) to substantial agreement (Kappa=0.61-0.80) following training using the CRDTS standard. Although this result differed qualitatively and Kappas were significantly different from 0, the differences for pre- to post-Kappas for patient-rater dyads using CRDTS were not statistically significant (p=0.778). There was no difference (p=0.913) in Kappa scores pre- to post-training using the scaling/root debridement standard. Despite the small number of participants in this study, the results indicated that training to improve interrater reliability to substantial agreement was feasible using the CRDTS standard but not using the gold standard. The difference may have been due to greater difficulty in attaining agreement regarding root roughness. Future studies should include multiple training sessions with patients using the same standard for scaling/root debridement used for evaluation of students.

  14. Diagnosis of gastrointestinal parasites in reptiles: comparison of two coprological methods

    PubMed Central

    2014-01-01

    Background Exotic reptiles have become increasingly common domestic pets worldwide and are well known to be carriers of different parasites including some with zoonotic potential. The need of accurate diagnosis of gastrointestinal endoparasite infections in domestic reptiles is therefore essential, not only for the well-being of captive reptiles but also for the owners. Here, two different approaches for the detection of parasite stages in reptile faeces were compared: a combination of native and iodine stained direct smears together with a flotation technique (CNF) versus the standard SAF-method. Results A total of 59 different reptile faeces (20 lizards, 22 snakes, 17 tortoises) were coprologically analyzed by the two methods for the presence of endoparasites. Analyzed reptile faecal samples contained a broad spectrum of parasites (total occurence 93.2%, n = 55) including different species of nematodes (55.9%, n = 33), trematodes (15.3%, n = 9), pentastomids (3.4%, n = 2) and protozoans (47.5%, n = 28). Associations between the performances of both methods to detect selected single parasite stages or groups of such were evaluated by Fisher's exact test and marginal homogeneity was tested by the McNemar test. In 88.1% of all examined samples (n = 52, 95% confidence interval [CI] = 77.1 - 95.1%) the two diagnostic methods rendered differing results, and the McNemar test for paired observations showed highly significant differences of the detection frequency (P < 0.0001). Conclusion The combination of direct smears/flotation proved superior in the detection of flagellates trophozoites, coccidian oocysts and nematode eggs, especially those of oxyurids. SAF-technique was superior in detecting larval stages and trematode eggs, but this advantage failed to be statistically significant (P = 0.13). Therefore, CNF is the recommended method for routine faecal examination of captive reptiles while the SAF-technique is advisable as additional measure particularly for wild caught animals and individuals which are to be introduced into captive collections. PMID:25299119

  15. Comparing viral metagenomics methods using a highly multiplexed human viral pathogens reagent

    PubMed Central

    Li, Linlin; Deng, Xutao; Mee, Edward T.; Collot-Teixeira, Sophie; Anderson, Rob; Schepelmann, Silke; Minor, Philip D.; Delwart, Eric

    2014-01-01

    Unbiased metagenomic sequencing holds significant potential as a diagnostic tool for the simultaneous detection of any previously genetically described viral nucleic acids in clinical samples. Viral genome sequences can also inform on likely phenotypes including drug susceptibility or neutralization serotypes. In this study, different variables of the laboratory methods often used to generate viral metagenomics libraries on the efficiency of viral detection and virus genome coverage were compared. A biological reagent consisting of 25 different human RNA and DNA viral pathogens was used to estimate the effect of filtration and nuclease digestion, DNA/RNA extraction methods, pre-amplification and the use of different library preparation kits on the detection of viral nucleic acids. Filtration and nuclease treatment led to slight decreases in the percentage of viral sequence reads and number of viruses detected. For nucleic acid extractions silica spin columns improved viral sequence recovery relative to magnetic beads and Trizol extraction. Pre-amplification using random RT-PCR while generating more viral sequence reads resulted in detection of fewer viruses, more overlapping sequences, and lower genome coverage. The ScriptSeq library preparation method retrieved more viruses and a greater fraction of their genomes than the TruSeq and Nextera methods. Viral metagenomics sequencing was able to simultaneously detect up to 22 different viruses in the biological reagent analyzed including all those detected by qPCR. Further optimization will be required for the detection of viruses in biologically more complex samples such as tissues, blood, or feces. PMID:25497414

  16. The potential for actigraphy to be used as an indicator of sitting discomfort.

    PubMed

    Telfer, Scott; Spence, William D; Solomonidis, Stephan E

    2009-10-01

    A novel technique that uses actigraphy, the study of activity involving the use of body-mounted accelerometers, to detect the discomfort-related movements of a sitting individual has been proposed as a potential indicator of sitting discomfort, and the purpose of this study was to test its validity. Objective measurement of sitting discomfort has always been challenging for researchers. Electromyographic measurements, pressure mapping, and a wide range of other techniques have all been investigated with limited success. The activity monitor's ability to detect and measure seated movement was assessed, and 12 participants were tested on four different chairs (100-min sessions for each). The activity monitor was able to detect participants' sitting movements (Pearson coefficients > 0.9). The chairs were shown to have significantly different subjective discomfort ratings, all of which increased over time. The movements detected by the activity monitor also increased significantly with time, and the amount measured was greater in the chairs rated as most uncomfortable. Regression analysis indicated that the actigraphy data were able to account for 29.6% of the variation in perceived discomfort ratings. Actigraphy can reliably detect sitting movements and may be of use in measuring sitting discomfort. Potential applications of this technique exist for seating research in the automotive industry, health care, and office and leisure chairs.

  17. Arsenic contamination of drinking water in Ireland: A spatial analysis of occurrence and potential risk.

    PubMed

    McGrory, Ellen R; Brown, Colin; Bargary, Norma; Williams, Natalya Hunter; Mannix, Anthony; Zhang, Chaosheng; Henry, Tiernan; Daly, Eve; Nicholas, Sarah; Petrunic, Barbara M; Lee, Monica; Morrison, Liam

    2017-02-01

    The presence of arsenic in groundwater has become a global concern due to the health risks from drinking water with elevated concentrations. The Water Framework Directive (WFD) of the European Union calls for drinking water risk assessment for member states. The present study amalgamates readily available national and sub-national scale datasets on arsenic in groundwater in the Republic of Ireland. However, due to the presence of high levels of left censoring (i.e. arsenic values below an analytical detection limit) and changes in detection limits over time, the application of conventional statistical methods would inhibit the generation of meaningful results. In order to handle these issues several arsenic databases were integrated and the data modelled using statistical methods appropriate for non-detect data. In addition, geostatistical methods were used to assess principal risk components of elevated arsenic related to lithology, aquifer type and groundwater vulnerability. Geographic statistical methods were used to overcome some of the geographical limitations of the Irish Environmental Protection Agency (EPA) sample database. Nearest-neighbour inverse distance weighting (IDW) and local indicator of spatial association (LISA) methods were used to estimate risk in non-sampled areas. Significant differences were also noted between different aquifer lithologies, indicating that Rhyolite, Sandstone and Shale (Greywackes), and Impure Limestone potentially presented a greater risk of elevated arsenic in groundwaters. Significant differences also occurred among aquifer types with poorly productive aquifers, locally important fractured bedrock aquifers and regionally important fissured bedrock aquifers presenting the highest potential risk of elevated arsenic. No significant differences were detected among different groundwater vulnerability groups as defined by the Geological Survey of Ireland. This research will assist management and future policy directions of groundwater resources at EU level and guide future research focused on understanding arsenic mobilisation processes to facilitate in guiding future development, testing and treatment requirements of groundwater resources. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Supervised target detection in hyperspectral images using one-class Fukunaga-Koontz Transform

    NASA Astrophysics Data System (ADS)

    Binol, Hamidullah; Bal, Abdullah

    2016-05-01

    A novel hyperspectral target detection technique based on Fukunaga-Koontz transform (FKT) is presented. FKT offers significant properties for feature selection and ordering. However, it can only be used to solve multi-pattern classification problems. Target detection may be considered as a two-class classification problem, i.e., target versus background clutter. Nevertheless, background clutter typically contains different types of materials. That's why; target detection techniques are different than classification methods by way of modeling clutter. To avoid the modeling of the background clutter, we have improved one-class FKT (OC-FKT) for target detection. The statistical properties of target training samples are used to define tunnel-like boundary of the target class. Non-target samples are then created synthetically as to be outside of the boundary. Thus, only limited target samples become adequate for training of FKT. The hyperspectral image experiments confirm that the proposed OC-FKT technique provides an effective means for target detection.

  19. Individual differences in event-based prospective memory: Evidence for multiple processes supporting cue detection.

    PubMed

    Brewer, Gene A; Knight, Justin B; Marsh, Richard L; Unsworth, Nash

    2010-04-01

    The multiprocess view proposes that different processes can be used to detect event-based prospective memory cues, depending in part on the specificity of the cue. According to this theory, attentional processes are not necessary to detect focal cues, whereas detection of nonfocal cues requires some form of controlled attention. This notion was tested using a design in which we compared performance on a focal and on a nonfocal prospective memory task by participants with high or low working memory capacity. An interaction was found, such that participants with high and low working memory performed equally well on the focal task, whereas the participants with high working memory performed significantly better on the nonfocal task than did their counterparts with low working memory. Thus, controlled attention was only necessary for detecting event-based prospective memory cues in the nonfocal task. These results have implications for theories of prospective memory, the processes necessary for cue detection, and the successful fulfillment of intentions.

  20. Radiologists' confidence in detecting abnormalities on chest images and their subjective judgments of image quality

    NASA Astrophysics Data System (ADS)

    King, Jill L.; Gur, David; Rockette, Howard E.; Curtin, Hugh D.; Obuchowski, Nancy A.; Thaete, F. Leland; Britton, Cynthia A.; Metz, Charles E.

    1991-07-01

    The relationship between subjective judgments of image quality for the performance of specific detection tasks and radiologists' confidence level in arriving at correct diagnoses was investigated in two studies in which 12 readers, using a total of three different display environments, interpreted a series of 300 PA chest images. The modalities used were conventional films, laser-printed films, and high-resolution CRT display of digitized images. For the detection of interstitial disease, nodules, and pneumothoraces, there was no statistically significant correlation (Spearman rho) between subjective ratings of quality and radiologists' confidence in detecting these abnormalities. However, in each study, for all modalities and all readers but one, a small but statistically significant correlation was found between the radiologists' ability to correctly and confidently rule out interstitial disease and their subjective ratings of image quality.

  1. Nanomaterial-enabled Rapid Detection of Water Contaminants.

    PubMed

    Mao, Shun; Chang, Jingbo; Zhou, Guihua; Chen, Junhong

    2015-10-28

    Water contaminants, e.g., inorganic chemicals and microorganisms, are critical metrics for water quality monitoring and have significant impacts on human health and plants/organisms living in water. The scope and focus of this review is nanomaterial-based optical, electronic, and electrochemical sensors for rapid detection of water contaminants, e.g., heavy metals, anions, and bacteria. These contaminants are commonly found in different water systems. The importance of water quality monitoring and control demands significant advancement in the detection of contaminants in water because current sensing technologies for water contaminants have limitations. The advantages of nanomaterial-based sensing technologies are highlighted and recent progress on nanomaterial-based sensors for rapid water contaminant detection is discussed. An outlook for future research into this rapidly growing field is also provided. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Impact of transgenic Cry1Ac + CpTI cotton on diversity and dynamics of rhizosphere bacterial community of different root environments.

    PubMed

    Li, Peng; Li, Yongchun; Shi, Jialiang; Yu, Zhibo; Pan, Aihu; Tang, Xueming; Ming, Feng

    2018-05-08

    The objective of this study was to characterize the diversity and dynamics of rhizosphere bacterial community, especially the response of dominant and rare bacterial taxa to the cultivation of Bt cotton for different root environments at different growth stages. qPCR analyses indicated that bacterial abundances of the taproots and lateral root rhizospheres of the Bt cotton SGK321 were significantly different at seedling and bolling stages. But no significant differences were detected between the same root zones from Bt and the conventional cotton varieties. Total bacterial genera had similar pattern with dominant genera in abundance, and with rare genera in richness to the changes of bacterial community, respectively. Although the rhizosphere bacterial diversity of the three cotton varieties changed in taproot and lateral root, no significant differences were detected in the same root environments between Bt and conventional cotton. Moreover, Soil pH was more correlated with variations in the bacterial community composition than Bt proteins. In conclusion, these results revealed no indication that rhizosphere bacterial community of Bt cotton had different response to increased Bt protein regarding the same root environment. In particular, dominant and rare bacterial taxa showed the variation in diversity and community composition in different root microhabitats. Copyright © 2018. Published by Elsevier B.V.

  3. Sustained change blindness to incremental scene rotation: a dissociation between explicit change detection and visual memory.

    PubMed

    Hollingworth, Andrew; Henderson, John M

    2004-07-01

    In a change detection paradigm, the global orientation of a natural scene was incrementally changed in 1 degree intervals. In Experiments 1 and 2, participants demonstrated sustained change blindness to incremental rotation, often coming to consider a significantly different scene viewpoint as an unchanged continuation of the original view. Experiment 3 showed that participants who failed to detect the incremental rotation nevertheless reliably detected a single-step rotation back to the initial view. Together, these results demonstrate an important dissociation between explicit change detection and visual memory. Following a change, visual memory is updated to reflect the changed state of the environment, even if the change was not detected.

  4. High precision automated face localization in thermal images: oral cancer dataset as test case

    NASA Astrophysics Data System (ADS)

    Chakraborty, M.; Raman, S. K.; Mukhopadhyay, S.; Patsa, S.; Anjum, N.; Ray, J. G.

    2017-02-01

    Automated face detection is the pivotal step in computer vision aided facial medical diagnosis and biometrics. This paper presents an automatic, subject adaptive framework for accurate face detection in the long infrared spectrum on our database for oral cancer detection consisting of malignant, precancerous and normal subjects of varied age group. Previous works on oral cancer detection using Digital Infrared Thermal Imaging(DITI) reveals that patients and normal subjects differ significantly in their facial thermal distribution. Therefore, it is a challenging task to formulate a completely adaptive framework to veraciously localize face from such a subject specific modality. Our model consists of first extracting the most probable facial regions by minimum error thresholding followed by ingenious adaptive methods to leverage the horizontal and vertical projections of the segmented thermal image. Additionally, the model incorporates our domain knowledge of exploiting temperature difference between strategic locations of the face. To our best knowledge, this is the pioneering work on detecting faces in thermal facial images comprising both patients and normal subjects. Previous works on face detection have not specifically targeted automated medical diagnosis; face bounding box returned by those algorithms are thus loose and not apt for further medical automation. Our algorithm significantly outperforms contemporary face detection algorithms in terms of commonly used metrics for evaluating face detection accuracy. Since our method has been tested on challenging dataset consisting of both patients and normal subjects of diverse age groups, it can be seamlessly adapted in any DITI guided facial healthcare or biometric applications.

  5. Use of the Wechsler Adult Intelligence Scale Digit Span subtest for malingering detection: a meta-analytic review.

    PubMed

    Jasinski, Lindsey J; Berry, David T R; Shandera, Anni L; Clark, Jessica A

    2011-03-01

    Twenty-four studies utilizing the Wechsler Adult Intelligence Scale (WAIS) Digit Span subtest--either the Reliable Digit Span (RDS) or Age-Corrected Scaled Score (DS-ACSS) variant--for malingering detection were meta-analytically reviewed to evaluate their effectiveness in detecting malingered neurocognitive dysfunction. RDS and DS-ACSS effectively discriminated between honest responders and dissimulators, with average weighted effect sizes of 1.34 and 1.08, respectively. No significant differences were found between RDS and DS-ACSS. Similarly, no differences were found between the Digit Span subtest from the WAIS or Wechsler Memory Scale (WMS). Strong specificity and moderate sensitivity were observed, and optimal cutting scores are recommended.

  6. Assessment of Gd-EOB-DTPA-enhanced MRI for HCC and dysplastic nodules and comparison of detection sensitivity versus MDCT.

    PubMed

    Inoue, Tatsuo; Kudo, Masatoshi; Komuta, Mina; Hayaishi, Sosuke; Ueda, Taisuke; Takita, Masahiro; Kitai, Satoshi; Hatanaka, Kinuyo; Yada, Norihisa; Hagiwara, Satoru; Chung, Hobyung; Sakurai, Toshiharu; Ueshima, Kazuomi; Sakamoto, Michiie; Maenishi, Osamu; Hyodo, Tomoko; Okada, Masahiro; Kumano, Seishi; Murakami, Takamichi

    2012-09-01

    We aimed to evaluate gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) for the detection of hepatocellular carcinomas (HCCs) and dysplastic nodules (DNs) compared with dynamic multi-detector row computed tomography (MDCT), and to discriminate between HCCs and DNs. Eighty-six nodules diagnosed as HCC or DNs were retrospectively investigated. Gd-EOB-DTPA-enhanced MRI and dynamic MDCT were compared with respect to their diagnostic ability for hypervascular HCCs and detection sensitivity for hypovascular tumors. The ability of hepatobiliary images of Gd-EOB-DTPA-enhanced MRI to discriminate between these nodules was assessed. We also calculated the EOB enhancement ratio of the tumors. For hypervascular HCCs, the diagnostic ability of Gd-EOB-DTPA-enhanced MRI was significantly higher than that of MDCT for tumors less than 2 cm (p = 0.048). There was no difference in the detection of hypervascular HCCs between hepatobiliary phase images of Gd-EOB-DTPA-enhanced MRI (43/45: 96%) and dynamic MDCT (40/45: 89%), whereas the detection sensitivity of hypovascular tumors by Gd-EOB-DTPA-enhanced MRI was significantly higher than that by dynamic MDCT (39/41: 95% vs. 25/41: 61%, p = 0.001). EOB enhancement ratios were decreased in parallel with the degree of differentiation in DNs and HCCs, although there was no difference between DNs and hypovascular well-differentiated HCCs. The diagnostic ability of Gd-EOB-DTPA-enhanced MRI for hypervascular HCCs less than 2 cm was significantly higher than that of MDCT. For hypovascular tumors, the detection sensitivity of hepatobiliary phase images of Gd-EOB-DTPA-enhanced MRI was significantly higher than that of dynamic Gd-EOB-DTPA-enhanced MRI and dynamic MDCT. It was difficult to distinguish between DNs and hypovascular well-differentiated HCCs based on the EOB enhancement ratio.

  7. Reaction Time and Attention: Toward a New Standard in the Assessment of ADHD? A Pilot Study.

    PubMed

    De la Torre, Gabriel G; Barroso, Juan M; León-Carrión, José; Mestre, Jose M; Bozal, Rocío Guil

    2015-12-01

    This pilot study shows results of an experiment comparing reaction times (RTs) and attentional performance between an ADHD group of 30 children and 30 controls, both Spanish speaking. The experiment was carried out using the Seville computerized neuropsychological battery (SNB). This study had two goals: One was to test sensitivity of SNB for attention deficits in ADHD and the second was to detect differences in RTs between ADHD and controls. Possible explanations and implications of such differences are also discussed. SNB computerized system was used to assess RTs and accuracy, and alternate forms of continuous performance task were used. Results showed high sensitivity of some of the SNB tests, especially cancellation tests. RTs were significantly different between groups. SNB represents a helpful tool for detection of attention deficits, and RT indices represent the most significant variable in differentiation of both groups studied. © The Author(s) 2012.

  8. Momentum-based morphometric analysis with application to Parkinson's disease

    NASA Astrophysics Data System (ADS)

    Chen, Jingyun; Khan, Ali R.; McKeown, Martin J.; Beg, Mirza F.

    2011-03-01

    We apply the initial momentum shape representation of diffeomorphic metric mapping from a template region of interest (ROI) to a given ROI as a morphometic marker in Parkinson's disease. We used a three-step segmentation-registrationmomentum process to derive feature vectors from ROIs in a group of 42 subjects consisting of 19 Parkinson's Disease (PD) subjects and 23 normal control (NC) subjects. Significant group differences between PD and NC subjects were detected in four basal ganglia structures including the caudate, putamen, thalamus and globus pallidus. The magnitude of regionally significant between-group differences detected ranged between 34-75%. Visualization of the different structural deformation pattern between-groups revealed that some parts of basal ganglia structure actually hypertrophy, presumably as a compensatory response to more widespread atrophy. Our results of both hypertrophy and atrophy in the same structures further demonstrate the importance of morphological measures as opposed to overall volume in the assessment of neurodegenerative disease.

  9. Contamination of different portions of raw and boiled specimens of Norway lobster by mercury and selenium.

    PubMed

    Perugini, Monia; Visciano, Pierina; Manera, Maurizio; Abete, Maria Cesarina; Gavinelli, Stefania; Amorena, Michele

    2013-11-01

    The aim of this study was to evaluate mercury and selenium distribution in different portions (exoskeleton, white meat and brown meat) of Norway lobster (Nephrops norvegicus). Some samples were also analysed as whole specimens. The same portions were also examined after boiling, in order to observe if this cooking practice could affect mercury and selenium concentrations. The highest mercury concentrations were detected in white meat, exceeding in all cases the maximum levels established by European legislation. The brown meat reported the highest selenium concentrations. In all boiled samples, mercury levels showed a statistically significant increase compared to raw portions. On the contrary, selenium concentrations detected in boiled samples of white meat, brown meat and whole specimen showed a statistically significant decrease compared to the corresponding raw samples. These results indicate that boiling modifies mercury and selenium concentrations. The high mercury levels detected represent a possible risk for consumers, and the publication and diffusion of specific advisories concerning seafood consumption is recommended.

  10. Evaluating camouflage design using eye movement data.

    PubMed

    Lin, Chiuhsiang Joe; Chang, Chi-Chan; Lee, Yung-Hui

    2014-05-01

    This study investigates the characteristics of eye movements during a camouflaged target search task. Camouflaged targets were randomly presented on two natural landscapes. The performance of each camouflage design was assessed by target detection hit rate, detection time, number of fixations on display, first saccade amplitude to target, number of fixations on target, fixation duration on target, and subjective ratings of search task difficulty. The results showed that the camouflage patterns could significantly affect the eye-movement behavior, especially first saccade amplitude and fixation duration, and the findings could be used to increase the sensitivity of the camouflage assessment. We hypothesized that the assessment could be made with regard to the differences in detectability and discriminability of the camouflage patterns. These could explain less efficient search behavior in eye movements. Overall, data obtained from eye movements can be used to significantly enhance the interpretation of the effects of different camouflage design. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  11. Comparison of animal infectivity, excystation, and fluorogenic dye as measures of Giardia muris cyst inactivation by ozone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labatiuk, C.W.; Finch, G.R.; Belosevic, M.

    1991-11-01

    Giardia muris cyst viability after ozonation was compared by using fluorescein diacetate-ethidium bromide staining, the C3H/HeN mouse-G. muris model, and in vitro excystation. Bench-scale batch experiments were conducted under laboratory conditions (pH 6.7, 22C) in ozone-demand-free phosphate buffer. There was a significant difference between fluorogenic staining and infectivity with fluorogenic staining overestimating viability compared with infectivity estimates of viability. This suggests that viable cysts as indicated by fluorogenic dyes may not be able to complete the life cycle and produce an infection. No significant differences between infectivity and excystation and between fluorogenic staining and excystation were detected for inactivations upmore » to 99.9%. Only animal infectivity had the sensitivity to detect inactivations greater than 99.9%. Therefore, the animal model is the best method currently available for detecting high levels of G. muris cyst inactivation.« less

  12. Point count length and detection of forest neotropical migrant birds

    USGS Publications Warehouse

    Dawson, D.K.; Smith, D.R.; Robbins, C.S.; Ralph, C. John; Sauer, John R.; Droege, Sam

    1995-01-01

    Comparisons of bird abundances among years or among habitats assume that the rates at which birds are detected and counted are constant within species. We use point count data collected in forests of the Mid-Atlantic states to estimate detection probabilities for Neotropical migrant bird species as a function of count length. For some species, significant differences existed among years or observers in both the probability of detecting the species and in the rate at which individuals are counted. We demonstrate the consequence that variability in species' detection probabilities can have on estimates of population change, and discuss ways for reducing this source of bias in point count studies.

  13. Eye Tracking and Head Movement Detection: A State-of-Art Survey

    PubMed Central

    2013-01-01

    Eye-gaze detection and tracking have been an active research field in the past years as it adds convenience to a variety of applications. It is considered a significant untraditional method of human computer interaction. Head movement detection has also received researchers' attention and interest as it has been found to be a simple and effective interaction method. Both technologies are considered the easiest alternative interface methods. They serve a wide range of severely disabled people who are left with minimal motor abilities. For both eye tracking and head movement detection, several different approaches have been proposed and used to implement different algorithms for these technologies. Despite the amount of research done on both technologies, researchers are still trying to find robust methods to use effectively in various applications. This paper presents a state-of-art survey for eye tracking and head movement detection methods proposed in the literature. Examples of different fields of applications for both technologies, such as human-computer interaction, driving assistance systems, and assistive technologies are also investigated. PMID:27170851

  14. Care dependency of hospitalized children: testing the Care Dependency Scale for Paediatrics in a cross-cultural comparison.

    PubMed

    Tork, Hanan; Dassen, Theo; Lohrmann, Christa

    2009-02-01

    This paper is a report of a study to examine the psychometric properties of the Care Dependency Scale for Paediatrics in Germany and Egypt and to compare the care dependency of school-age children in both countries. Cross-cultural differences in care dependency of older adults have been documented in the literature, but little is known about the differences and similarities with regard to children's care dependency in different cultures. A convenience sample of 258 school-aged children from Germany and Egypt participated in the study in 2005. The reliability of the Care Dependency Scale for Paediatrics was assessed in terms of internal consistency and interrater reliability. Factor analysis (principal component analysis) was employed to verify the construct validity. A Visual Analogue Scale was used to investigate the criterion-related validity. Good internal consistency was detected both for the Arabic and German versions. Factor analysis revealed one factor for both versions. A Pearson's correlation between the Care Dependency Scale for Paediatrics and Visual Analogue Scale was statistically significant for both versions indicating criterion-related validity. Statistically significant differences between the participants were detected regarding the mean sum score on the Care Dependency Scale for Paediatrics. The Care Dependency Scale for Paediatrics is a reliable and valid tool for assessing the care dependency of children and is recommended for assessing the care dependency of children from different ethnic origins. Differences in care dependency between German and Egyptian children were detected, which might be due to cultural differences.

  15. Diagnostic values of different definitions of metabolic syndrome to detect poor health status in Iranian adults without diabetes.

    PubMed

    Amiri, P; Deihim, T; Hosseinpanah, F; Barzin, M; Hasheminia, M; Montazeri, A; Azizi, F

    2014-07-01

    This study aimed to compare the diagnostic impact of four definitions of the metabolic syndrome for detection of poor health status in adults without diabetes living in Tehran. A representative sample of 950 individuals (64% women), aged ≥ 20 years, participants of the Tehran Lipid and Glucose Study in 2005-2007, were recruited for the study. Health status was assessed using the Iranian version of the 36-item Short Form Health Survey. We assessed the detectability of poor health status by definitions of the National Cholesterol Education Program Adult Treatment Panel III, the International Diabetes Federation, the American Heart Association/National Heart, Lung, and the Blood Institute and the Joint Interim Statement. Compared with other definitions, the Joint Interim Statement identified more participants (46.9%) having the metabolic syndrome. Using the National Cholesterol Education Program Adult Treatment Panel III, the International Diabetes Federation and the Joint Interim Statement, the metabolic syndrome was significantly related to poor physical health status, even after adjustment for confounding variables, in women, but not in men. None of the four definitions of the metabolic syndrome was related to the mental health status in either gender. The receiver operating characteristic curves showed no significant difference in the discriminative power of the metabolic syndrome definitions in detecting poor health status in either gender. However, women showed a higher area under the curve for all definitions, in comparison with men. There was no difference in the four different definitions of the metabolic syndrome in detecting poor health status among Iranian adults. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  16. HPLC-DAD-MS(n) characterisation of carotenoids from apricots and pumpkins for the evaluation of fruit product authenticity.

    PubMed

    Kurz, Christina; Carle, Reinhold; Schieber, Andreas

    2008-09-15

    Carotenoids including carotenoid esters from six apricot (Prunus armeniaca L.) cultivars and from eight cultivars from three pumpkin species (Cucurbita maxima Duch., Cucurbita pepo L., and Cucurbita moschata Duch.) were extracted without saponification, separated on a C-30 reversed-phase column and characterised by high-performance liquid chromatography/atmospheric pressure chemical ionisation-mass spectrometry (LC-MS). The predominant free carotenoids were quantified by HPLC with diode array detection. In contrast to previously published data, α-carotene could not be detected in apricots. Although the pumpkins showed significant differences in their free carotenoid profiles, major unesterified compounds different from those found in apricots could be determined. However, due to the natural heterogeneity, authentication of the apricot products cannot be accomplished exclusively using the profile of free carotenoids. Therefore, the investigations were extended to carotenoid esters. The xanthophyll ester profiles in pumpkins significantly differed from those in apricots in that the latter also contained both saturated and unsaturated fatty acids, whereas in pumpkins exclusively saturated fatty acids were detected. Admixtures of lower cost pumpkins could be detected in quantities of ⩾5% by increased contents of lutein and zeaxanthin, and by the appearance of antheraxanthin and α-carotene, respectively, depending on the added pumpkin cultivar, as well as the presence of characteristic lutein and antheraxanthin esters. However, pronounced differences in the carotenoid profiles of the investigated pumpkins and the partly minor amount of characteristic compounds lead to limitations of the detection of 5% level of admixture of pumpkin to apricot and of the method in general. Copyright © 2008 Elsevier Ltd. All rights reserved.

  17. [Clinical significance of calcitonin gene-related peptide level before and after treatment in patients with chronic periodontitis].

    PubMed

    Yan, Ying; Xiang, Xue-Rong; Wang, Chun; Ye, Guo; Fan, Xiao-Ping

    2016-08-01

    To explore the clinical significance of calcitonin gene-related peptide (CGRP) levels in patients with chronic periodontitis before and after treatment, and to detect the calcitonin gene-related peptide content in human venous blood. Thirty healthy controls and thirty patients with mild, moderate, severe periodontitis were enrolled from August 2014 to June 2015.CGRP level in the patients' peripheral blood was detected by ELISA. Three months after periodontal treatment, CGRP level in mild, moderate, severe periodontitis patients' peripheral blood was re-examined by ELISA. Then the correlation between calcitonin gene-related peptide and inflammation of chronic periodontitis was analyzed with SPSS 22.0 software package. The content of CGRP in healthy controls was significantly higher than that in patients with periodontitis. With the aggravation of periodontal inflammation, blood level of CGRP decreased gradually, and the lowest was in patients with severe periodontitis (P<0.01). Three months after periodontal treatment, CGRP content was significantly higher compared with that before treatment (P<0.05), but no significant difference was found in patients with different degree of periodontitis (P>0.05). The level of CGRP in venous blood decreased with the increasing severity of chronic periodontitis, and CGRP was negatively correlated with the degree of inflammation of chronic periodontitis. CGRP may be involved in the occurrence and development of chronic periodontitis. CGRP content in serum of patients with chronic periodontitis after treatment was significantly increased, CGRP may be used as the basis for clinical detection of chronic periodontitis.

  18. Estimating babassu palm density using automatic palm tree detection with very high spatial resolution satellite images.

    PubMed

    Dos Santos, Alessio Moreira; Mitja, Danielle; Delaître, Eric; Demagistri, Laurent; de Souza Miranda, Izildinha; Libourel, Thérèse; Petit, Michel

    2017-05-15

    High spatial resolution images as well as image processing and object detection algorithms are recent technologies that aid the study of biodiversity and commercial plantations of forest species. This paper seeks to contribute knowledge regarding the use of these technologies by studying randomly dispersed native palm tree. Here, we analyze the automatic detection of large circular crown (LCC) palm tree using a high spatial resolution panchromatic GeoEye image (0.50 m) taken on the area of a community of small agricultural farms in the Brazilian Amazon. We also propose auxiliary methods to estimate the density of the LCC palm tree Attalea speciosa (babassu) based on the detection results. We used the "Compt-palm" algorithm based on the detection of palm tree shadows in open areas via mathematical morphology techniques and the spatial information was validated using field methods (i.e. structural census and georeferencing). The algorithm recognized individuals in life stages 5 and 6, and the extraction percentage, branching factor and quality percentage factors were used to evaluate its performance. A principal components analysis showed that the structure of the studied species differs from other species. Approximately 96% of the babassu individuals in stage 6 were detected. These individuals had significantly smaller stipes than the undetected ones. In turn, 60% of the stage 5 babassu individuals were detected, showing significantly a different total height and a different number of leaves from the undetected ones. Our calculations regarding resource availability indicate that 6870 ha contained 25,015 adult babassu palm tree, with an annual potential productivity of 27.4 t of almond oil. The detection of LCC palm tree and the implementation of auxiliary field methods to estimate babassu density is an important first step to monitor this industry resource that is extremely important to the Brazilian economy and thousands of families over a large scale. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. A Comparison of the Sensitivity and Fecal Egg Counts of the McMaster Egg Counting and Kato-Katz Thick Smear Methods for Soil-Transmitted Helminths

    PubMed Central

    Levecke, Bruno; Behnke, Jerzy M.; Ajjampur, Sitara S. R.; Albonico, Marco; Ame, Shaali M.; Charlier, Johannes; Geiger, Stefan M.; Hoa, Nguyen T. V.; Kamwa Ngassam, Romuald I.; Kotze, Andrew C.; McCarthy, James S.; Montresor, Antonio; Periago, Maria V.; Roy, Sheela; Tchuem Tchuenté, Louis-Albert; Thach, D. T. C.; Vercruysse, Jozef

    2011-01-01

    Background The Kato-Katz thick smear (Kato-Katz) is the diagnostic method recommended for monitoring large-scale treatment programs implemented for the control of soil-transmitted helminths (STH) in public health, yet it is difficult to standardize. A promising alternative is the McMaster egg counting method (McMaster), commonly used in veterinary parasitology, but rarely so for the detection of STH in human stool. Methodology/Principal Findings The Kato-Katz and McMaster methods were compared for the detection of STH in 1,543 subjects resident in five countries across Africa, Asia and South America. The consistency of the performance of both methods in different trials, the validity of the fixed multiplication factor employed in the Kato-Katz method and the accuracy of these methods for estimating ‘true’ drug efficacies were assessed. The Kato-Katz method detected significantly more Ascaris lumbricoides infections (88.1% vs. 75.6%, p<0.001), whereas the difference in sensitivity between the two methods was non-significant for hookworm (78.3% vs. 72.4%) and Trichuris trichiura (82.6% vs. 80.3%). The sensitivity of the methods varied significantly across trials and magnitude of fecal egg counts (FEC). Quantitative comparison revealed a significant correlation (Rs >0.32) in FEC between both methods, and indicated no significant difference in FEC, except for A. lumbricoides, where the Kato-Katz resulted in significantly higher FEC (14,197 eggs per gram of stool (EPG) vs. 5,982 EPG). For the Kato-Katz, the fixed multiplication factor resulted in significantly higher FEC than the multiplication factor adjusted for mass of feces examined for A. lumbricoides (16,538 EPG vs. 15,396 EPG) and T. trichiura (1,490 EPG vs. 1,363 EPG), but not for hookworm. The McMaster provided more accurate efficacy results (absolute difference to ‘true’ drug efficacy: 1.7% vs. 4.5%). Conclusions/Significance The McMaster is an alternative method for monitoring large-scale treatment programs. It is a robust (accurate multiplication factor) and accurate (reliable efficacy results) method, which can be easily standardized. PMID:21695104

  20. Detectability of BI-RADS category 3 or higher breast lesions and reading time on mammography: comparison between 5-MP and 8-MP LCD monitors.

    PubMed

    Yabuuchi, Hidetake; Kawanami, Satoshi; Kamitani, Takeshi; Matsumura, Tomomi; Yamasaki, Yuzo; Morishita, Junji; Honda, Hiroshi

    2017-04-01

    Background Five-megapixel (MP) displays are recommended as soft copy devices for digital mammogram. An 8-MP liquid crystal display (LCD) (two 4-MP displays within one display) might offer the advantage of being able to view biplane mammography more easily than the dual planes of 5-MP LCDs. Purpose To compare detectability of Breast Imaging Reporting and Data System (BI-RADS) category 3 or higher lesions and reading time on mammography between 5- MP and 8-MP LCDs. Material and Methods The mammograms of 240 breasts of 120 patients including 60 breasts with BI-RADS category 3 or higher lesions and 180 breasts with normal or category 2 lesions were enrolled. All bilateral mammograms were displayed on bifacial 5-MP LCDs or an 8-MP LCD (two 4-MP displays within one display). Six radiologists assessed 240 breasts on each display. The observations were analyzed using receiver operating characteristic (ROC) analysis. A jack-knife method was used for statistical analysis. We employed a paired t-test to determine whether any significant differences existed in the reading time between two different displays. A P value < 0.05 was considered significant. Results The mean areas under the ROC curve obtained using 5-MP and 8-MP LCDs were 0.925 and 0.915, respectively, and there was no significant difference ( P = 0.46). There was also no significant difference in the reading time between two types of displays (57.8 min. vs. 51.5 min, P = 0.39). Conclusion The detectability of BI-RADS category 3 or higher lesions and reading time using an 8-MP LCD were comparable to those using a 5-MP LCD.

  1. Free radical release and HSP70 expression in two human immune-relevant cell lines after exposure to 1800 MHz radiofrequency radiation.

    PubMed

    Lantow, M; Schuderer, J; Hartwig, C; Simkó, M

    2006-01-01

    The goal of this study was to investigate whether radiofrequency (RF) electromagnetic-field (EMF) exposure at 1800 MHz causes production of free radicals and/or expression of heat-shock proteins (HSP70) in human immune-relevant cell systems. Human Mono Mac 6 and K562 cells were used to examine free radical release after exposure to incubator control, sham, RF EMFs, PMA, LPS, heat (40 degrees C) or co-exposure conditions. Several signals were used: continuous-wave, several typical modulations of the Global System for Mobile Communications (GSM): GSM-non DTX (speaking only), GSM-DTX (hearing only), GSM-Talk (34% speaking and 66% hearing) at specific absorption rates (SARs) of 0.5, 1.0, 1.5 and 2.0 W/kg. Heat and PMA treatment induced a significant increase in superoxide radical anions and in ROS production in the Mono Mac 6 cells when compared to sham and/or incubator conditions. No significant differences in free radical production were detected after RF EMF exposure or in the respective controls, and no additional effects on superoxide radical anion production were detected after co-exposure to RF EMFs+PMA or RF EMFs+LPS. The GSM-DTX signal at 2 W/kg produced a significant difference in free radical production when the data were compared to sham because of the decreasing sham value. This difference disappeared when data were compared to the incubator controls. To determine the involvement of heat-shock proteins as a possible inhibitor of free radical production, we investigated the HSP70 expression level after different RF EMF exposures; no significant effects were detected.

  2. Biomonitoring of chemical exposure among New York City firefighters responding to the World Trade Center fire and collapse.

    PubMed

    Edelman, Philip; Osterloh, John; Pirkle, James; Caudill, Sam P; Grainger, James; Jones, Robert; Blount, Ben; Calafat, Antonia; Turner, Wayman; Feldman, Debra; Baron, Sherry; Bernard, Bruce; Lushniak, Boris D; Kelly, Kerry; Prezant, David

    2003-12-01

    The collapse of the World Trade Center (WTC) on 11 September 2001 exposed New York City firefighters to smoke and dust of unprecedented magnitude and duration. The chemicals and the concentrations produced from any fire are difficult to predict, but estimates of internal dose exposures can be assessed by the biological monitoring of blood and urine. We analyzed blood and urine specimens obtained from 321 firefighters responding to the WTC fires and collapse for 110 potentially fire-related chemicals. Controls consisted of 47 firefighters not present at the WTC. Sampling occurred 3 weeks after 11 September, while fires were still burning. When reference or background ranges were available, most chemical concentrations were found to be generally low and not outside these ranges. Compared with controls, the exposed firefighters showed significant differences in adjusted geometric means for six of the chemicals and significantly greater detection rates for an additional three. Arrival time was a significant predictor variable for four chemicals. Special Operations Command firefighters (n = 95), compared with other responding WTC firefighters (n = 226), had differences in concentrations or detection rate for 14 of the chemicals. Values for the Special Operations Command firefighters were also significantly different from the control group values for these same chemicals and for two additional chemicals. Generally, the chemical concentrations in the other firefighter group were not different from those of controls. Biomonitoring was used to characterize firefighter exposure at the WTC disaster. Although some of the chemicals analyzed showed statistically significant differences, these differences were generally small.

  3. A diffusional kurtosis imaging study of idiopathic generalized epilepsy with unilateral interictal epileptiform discharges in children.

    PubMed

    Zhang, Yuzhen; Gao, Yu; Zhou, Minxiong; Wu, Jie; Zee, Chishing; Wang, Dengbin

    2016-10-01

    To investigate brain abnormalities in children with a clinical diagnosis of idiopathic generalized epilepsy (IGE) and unilateral interictal epileptiform discharges (IED) demonstrated on electroencephalography (EEG) by diffusional kurtosis imaging (DKI). DKI images were obtained from 18 patients (n=9 each in the left and right hemispheres). Fractional anisotropy (FA), mean diffusivity (MD), and mean kurtosis (MK) maps were estimated through voxel-based analyses, and compared with 18 normal controls matched for age and sex. In the left side group, the significant differences of FA were in the left fusiform gyrus and occipital lobe of the white matter (WM). The significant differences of MD were in the left pons. The significant differences of MK were in the anterior cingulate gyrus, limbic lobe, gray matter (GM) and WM of the right cerebrum. In the right side group, the significant differences of FA were in the WM of the left cerebrum. MD identified differences in the frontal, temporal, occipital, and parietal lobes of both hemispheres, especially in the limbic system, fusiform gyrus, uncus, and parahippocampal gyrus. The significant differences of MK were in the GM of the right cerebrum, particularly in the rolandic operculum and frontal lobe. DKI is sensitive for the detection of diffusion abnormalities in both WM and GM of IGE in children. Secondary brain abnormalities may exist in regions outside the unilateral epileptogenic zone through the limbic epileptic network, and can be detected by DKI indices FA, MD and MK. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. Flow cytometry, morphometry and histopathology as biomarkers of benzo[a]pyrene exposure in brown bullheads (ameiurus nebulosus)

    USGS Publications Warehouse

    Grady, Andrew W.; McLaughlin, Ronald M.; Caldwell, Charles W.; Schmitt, Christopher J.; Stalling, David L.

    1992-01-01

    Brown bullheads were given a single intraperitoneal dose of 0, 5, 25 or 125 mg kg−1 benzo[a]pyrene (BaP), a carcinogenic polycyclic aromatic hydrocarbon, and evaluated over 18 months. Flow cytometric analyses of hepatocyte DNA content indicated an increase in DNA synthesis in BaP-exposed fish prior to day 14 post-exposure. Thereafter, all flow cytometric variables returned to initial levels. Histopathological evaluation of livers from fish sampled at 18 months revealed significant differences among treatments in the amount of hepatic macrophage ceroid pigmentation and basophilic staining intensity. No neoplasms or changes in blood cell DNA content were detected. Significant morphometric variations existed among fish, but differences between sexes overshadowed differences attributable to dose. Flow cytometry yielded no evidence of long-term DNA alterations from a single exposure to BaP; however, the differences detected by DNA analysis shortly after the toxic event suggest that flow cytometric cell cycle analysis may be useful for documenting continuing exposures.

  5. Effects of dose reduction on the detectability of standardized radiolucent lesions in digital panoramic radiography.

    PubMed

    Dula, K; Sanderink, G; van der Stelt, P F; Mini, R; Buser, D

    1998-08-01

    Dose reduction in digital panoramic radiography was studied. Intentional underexposure was performed with the Orthophos DS while six different human mandibles were radiographed. Exposure settings were 69 kV/15 mA (standard), 64 kV/16 mA, and 60 kV/16 mA. Standardized spherical defects, each either 1 or 1.25 mm in diameter, were simulated in 288 of 432 images, and seven observers decided whether defects were present or not. Areas under the receiver operating characteristics curves were calculated. They showed no significant differences in the detectability of the 1-mm defect at 69, 64, or 60 kV. For the 1.25-mm defect, no difference was found between the 69 and 60 kV images, but a statistically significant different detectability was found for 64 kV images in comparison with both 69 and 60 kV images. A dose reduction of up to 43% was ascertained with a Pedo-RT-Humanoid phantom when panoramic radiography was performed at 60 kV/16 mA. The conclusion is that with the Orthophos DS, it seems possible to reduce the dose rate of x-rays without loss of diagnostic quality in the case of radiolucent changes.

  6. CANTAB object recognition and language tests to detect aging cognitive decline: an exploratory comparative study

    PubMed Central

    Cabral Soares, Fernanda; de Oliveira, Thaís Cristina Galdino; de Macedo, Liliane Dias e Dias; Tomás, Alessandra Mendonça; Picanço-Diniz, Domingos Luiz Wanderley; Bento-Torres, João; Bento-Torres, Natáli Valim Oliver; Picanço-Diniz, Cristovam Wanderley

    2015-01-01

    Objective The recognition of the limits between normal and pathological aging is essential to start preventive actions. The aim of this paper is to compare the Cambridge Neuropsychological Test Automated Battery (CANTAB) and language tests to distinguish subtle differences in cognitive performances in two different age groups, namely young adults and elderly cognitively normal subjects. Method We selected 29 young adults (29.9±1.06 years) and 31 older adults (74.1±1.15 years) matched by educational level (years of schooling). All subjects underwent a general assessment and a battery of neuropsychological tests, including the Mini Mental State Examination, visuospatial learning, and memory tasks from CANTAB and language tests. Cluster and discriminant analysis were applied to all neuropsychological test results to distinguish possible subgroups inside each age group. Results Significant differences in the performance of aged and young adults were detected in both language and visuospatial memory tests. Intragroup cluster and discriminant analysis revealed that CANTAB, as compared to language tests, was able to detect subtle but significant differences between the subjects. Conclusion Based on these findings, we concluded that, as compared to language tests, large-scale application of automated visuospatial tests to assess learning and memory might increase our ability to discern the limits between normal and pathological aging. PMID:25565785

  7. Using uterine activity to improve fetal heart rate variability analysis for detection of asphyxia during labor.

    PubMed

    Warmerdam, G J J; Vullings, R; Van Laar, J O E H; Van der Hout-Van der Jagt, M B; Bergmans, J W M; Schmitt, L; Oei, S G

    2016-03-01

    During labor, uterine contractions can cause temporary oxygen deficiency for the fetus. In case of severe and prolonged oxygen deficiency this can lead to asphyxia. The currently used technique for detection of asphyxia, cardiotocography (CTG), suffers from a low specificity. Recent studies suggest that analysis of fetal heart rate variability (HRV) in addition to CTG can provide information on fetal distress. However, interpretation of fetal HRV during labor is difficult due to the influence of uterine contractions on fetal HRV. The aim of this study is therefore to investigate whether HRV features differ during contraction and rest periods, and whether these differences can improve the detection of asphyxia. To this end, a case-control study was performed, using 14 cases with asphyxia that were matched with 14 healthy fetuses. We did not find significant differences for individual HRV features when calculated over the fetal heart rate without separating contractions and rest periods (p  >  0.30 for all HRV features). Separating contractions from rest periods did result in a significant difference. In particular the ratio between HRV features calculated during and outside contractions can improve discrimination between fetuses with and without asphyxia (p  <  0.04 for three out of four ratio HRV features that were studied in this paper).

  8. Detection biases yield misleading patterns of species persistence and colonization in fragmented landscapes

    USGS Publications Warehouse

    Ruiz-Gutierrez, Viviana; Zipkin, Elise F.

    2011-01-01

    Species occurrence patterns, and related processes of persistence, colonization and turnover, are increasingly being used to infer habitat suitability, predict species distributions, and measure biodiversity potential. The majority of these studies do not account for observational error in their analyses despite growing evidence suggesting that the sampling process can significantly influence species detection and subsequently, estimates of occurrence. We examined the potential biases of species occurrence patterns that can result from differences in detectability across species and habitat types using hierarchical multispecies occupancy models applied to a tropical bird community in an agricultural fragmented landscape. Our results suggest that detection varies widely among species and habitat types. Not incorporating detectability severely biased occupancy dynamics for many species by overestimating turnover rates, producing misleading patterns of persistence and colonization of agricultural habitats, and misclassifying species into ecological categories (i.e., forest specialists and generalists). This is of serious concern, given that most research on the ability of agricultural lands to maintain current levels of biodiversity by and large does not correct for differences in detectability. We strongly urge researchers to apply an inferential framework which explicitly account for differences in detectability to fully characterize species-habitat relationships, correctly guide biodiversity conservation in human-modified landscapes, and generate more accurate predictions of species responses to future changes in environmental conditions.

  9. Efficacy of Pseudomonas fluorescens strain CL145A spray dried powder for controlling zebra mussels adhering to native unionid mussels within field enclosures

    USGS Publications Warehouse

    Luoma, James A.; Weber, Kerry L.; Severson, Todd J.; Mayer, Denise A.

    2015-01-01

    Group 1 mussel survival did not differ between treatment groups (p > 0.05); however, a difference was detected (p < 0.01) in the survival of Group 2 mussels. The survival of Group 2 mussels did not differ (p > 0.23) between control and treated groups. A difference in Group 2 mussel survival was detected (p = 0.03; odds ratio [OR] = 0.290) between the 50- and 100-mg/L treatment groups (that is, the survival was highest in the 50-mg/L treatment group and lowest in the 100-mg/L treatment group), however, the biological significance of the difference is indeterminate.

  10. Does MRI scan acceleration affect power to track brain change?

    PubMed

    Ching, Christopher R K; Hua, Xue; Hibar, Derrek P; Ward, Chadwick P; Gunter, Jeffrey L; Bernstein, Matt A; Jack, Clifford R; Weiner, Michael W; Thompson, Paul M

    2015-01-01

    The Alzheimer's Disease Neuroimaging Initiative recently implemented accelerated T1-weighted structural imaging to reduce scan times. Faster scans may reduce study costs and patient attrition by accommodating people who cannot tolerate long scan sessions. However, little is known about how scan acceleration affects the power to detect longitudinal brain change. Using tensor-based morphometry, no significant difference was detected in numerical summaries of atrophy rates from accelerated and nonaccelerated scans in subgroups of patients with Alzheimer's disease, early or late mild cognitive impairment, or healthy controls over a 6- and 12-month scan interval. Whole-brain voxelwise mapping analyses revealed some apparent regional differences in 6-month atrophy rates when comparing all subjects irrespective of diagnosis (n = 345). No such whole-brain difference was detected for the 12-month scan interval (n = 156). Effect sizes for structural brain changes were not detectably different in accelerated versus nonaccelerated data. Scan acceleration may influence brain measures but has minimal effects on tensor-based morphometry-derived atrophy measures, at least over the 6- and 12-month intervals examined here. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Value of the polymerase chain reaction method for detecting tuberculosis in the bronchial tissue involved by anthracosis.

    PubMed

    Mirsadraee, Majid; Shafahie, Ahmad; Reza Khakzad, Mohammad; Sankian, Mojtaba

    2014-04-01

    Anthracofibrosis is the black discoloration of the bronchial mucosa with deformity and obstruction. Association of this disease with tuberculosis (TB) was approved. The objective of this study was to find the additional benefit of assessment of TB by the polymerase chain reaction (PCR) method. Bronchoscopy was performed on 103 subjects (54 anthracofibrosis and 49 control subjects) who required bronchoscopy for their pulmonary problems. According to bronchoscopic findings, participants were classified to anthracofibrosis and nonanthracotic groups. They were examined for TB with traditional methods such as direct smear (Ziehl-Neelsen staining), Löwenstein-Jensen culture, and histopathology and the new method "PCR" for Mycobacterium tuberculosis genome (IS6110). Age, sex, smoking, and clinical findings were not significantly different in the TB and the non-TB groups. Acid-fast bacilli could be detected by a direct smear in 12 (25%) of the anthracofibrosis subjects, and adding the results of culture and histopathology traditional tests indicated TB in 27 (31%) of the cases. Mycobacterium tuberculosis was diagnosed by PCR in 18 (33%) patients, but the difference was not significant. Detection of acid-fast bacilli in control nonanthracosis subjects was significantly lower (3, 6%), but PCR (20, 40%) and accumulation of results from all traditional methods (22, 44%) showed a nonsignificant difference. The PCR method showed a result equal to traditional methods including accumulation of smear, culture, and histopathology.

  12. Systematic evaluation of deep learning based detection frameworks for aerial imagery

    NASA Astrophysics Data System (ADS)

    Sommer, Lars; Steinmann, Lucas; Schumann, Arne; Beyerer, Jürgen

    2018-04-01

    Object detection in aerial imagery is crucial for many applications in the civil and military domain. In recent years, deep learning based object detection frameworks significantly outperformed conventional approaches based on hand-crafted features on several datasets. However, these detection frameworks are generally designed and optimized for common benchmark datasets, which considerably differ from aerial imagery especially in object sizes. As already demonstrated for Faster R-CNN, several adaptations are necessary to account for these differences. In this work, we adapt several state-of-the-art detection frameworks including Faster R-CNN, R-FCN, and Single Shot MultiBox Detector (SSD) to aerial imagery. We discuss adaptations that mainly improve the detection accuracy of all frameworks in detail. As the output of deeper convolutional layers comprise more semantic information, these layers are generally used in detection frameworks as feature map to locate and classify objects. However, the resolution of these feature maps is insufficient for handling small object instances, which results in an inaccurate localization or incorrect classification of small objects. Furthermore, state-of-the-art detection frameworks perform bounding box regression to predict the exact object location. Therefore, so called anchor or default boxes are used as reference. We demonstrate how an appropriate choice of anchor box sizes can considerably improve detection performance. Furthermore, we evaluate the impact of the performed adaptations on two publicly available datasets to account for various ground sampling distances or differing backgrounds. The presented adaptations can be used as guideline for further datasets or detection frameworks.

  13. Peptide Functionalized Gold Nanorods for the Sensitive Detection of a Cardiac Biomarker Using Plasmonic Paper Devices (Postprint)

    DTIC Science & Technology

    2015-11-10

    valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YY) 2. REPORT TYPE 3 . DATES COVERED (From...refractive index difference on the order of 3 × 10−4 refractive index units (RIU)), probe the conformational changes of individual biomacromolecules, detect...natural antibodies and short peptides, as BREs. We demonstrate that pep - tides provide a significantly higher sensitivity and lower limit of detection

  14. Post-genomic insights into the plant polysaccharide degradation potential of Aspergillus nidulans and comparison to Aspergillus niger and Aspergillus oryzae.

    PubMed

    Coutinho, Pedro M; Andersen, Mikael R; Kolenova, Katarina; vanKuyk, Patricia A; Benoit, Isabelle; Gruben, Birgit S; Trejo-Aguilar, Blanca; Visser, Hans; van Solingen, Piet; Pakula, Tiina; Seiboth, Bernard; Battaglia, Evy; Aguilar-Osorio, Guillermo; de Jong, Jan F; Ohm, Robin A; Aguilar, Mariana; Henrissat, Bernard; Nielsen, Jens; Stålbrand, Henrik; de Vries, Ronald P

    2009-03-01

    The plant polysaccharide degradative potential of Aspergillus nidulans was analysed in detail and compared to that of Aspergillus niger and Aspergillus oryzae using a combination of bioinformatics, physiology and transcriptomics. Manual verification indicated that 28.4% of the A. nidulans ORFs analysed in this study do not contain a secretion signal, of which 40% may be secreted through a non-classical method.While significant differences were found between the species in the numbers of ORFs assigned to the relevant CAZy families, no significant difference was observed in growth on polysaccharides. Growth differences were observed between the Aspergilli and Podospora anserina, which has a more different genomic potential for polysaccharide degradation, suggesting that large genomic differences are required to cause growth differences on polysaccharides. Differences were also detected between the Aspergilli in the presence of putative regulatory sequences in the promoters of the ORFs of this study and correlation of the presence of putative XlnR binding sites to induction by xylose was detected for A. niger. These data demonstrate differences at genome content, substrate specificity of the enzymes and gene regulation in these three Aspergilli, which likely reflect their individual adaptation to their natural biotope.

  15. Seroprevalence of Human Papillomavirus (HPV) Type 6, 11, 16, 18, by Anatomic Site of HPV Infection, in Women Aged 16-64 Years living in the Metropolitan Area of San Juan, Puerto Rico.

    PubMed

    Pérez-Caraballo, Aixa M; Suarez, Erick; Unger, Elizabeth R; Palefsky, Joel M; Panicker, Gitika; Ortiz, Ana Patricia

    2018-03-01

    It is unknown if human papillomavirus (HPV) serum antibody responses vary by anatomic site of infection. We aimed to assess the seroprevalence for HPV 6, 11, 16 and 18 in association with HPV DNA detection in different anatomic sites among women. This cross sectional population-based study analyzed data from 524 women aged 16-64 years living in the San Juan metropolitan area of Puerto Rico (PR). Questionnaires were used to assess demographic and lifestyle variables, while anogenital and blood samples were collected for HPV analysis. Logistic regression models were used to estimate the adjusted prevalence odds ratio (POR) in order to determine the association between HPV DNA infection status in the cervix and anus and serum antibody status, controlling for different potential confounders. Overall, 46.9% of women had detectable antibodies to one or more types whereas 8.7% had HPV DNA for one or more of these types detected in cervix (4.0%) or anus (6.5%). Women with cervical HPV detection tended to be more HPV seropositive than women without cervical detection (adjusted POR (95%CI): 2.41 (0.90, 6.47), p=0.078); however the type-specific association between cervical DNA and serum antibodies was only significant for HPV 18 (adjusted POR (95% CI): 5.9 (1.03, 33.98)). No significant association was detected between anal HPV and seropositivity (p>0.10). Differences in the anatomic site of infection could influence seroconversion, however, longitudinal studies will be required for further evaluation. This information will be instrumental in advancing knowledge of immune mechanisms involved in anatomic site response.

  16. Comparison of 5 Ki-67 antibodies regarding reproducibility and capacity to predict prognosis in breast cancer: does the antibody matter?

    PubMed

    Ács, Balázs; Kulka, Janina; Kovács, Kristóf Attila; Teleki, Ivett; Tőkés, Anna-Mária; Meczker, Ágnes; Győrffy, Balázs; Madaras, Lilla; Krenács, Tibor; Szász, Attila Marcell

    2017-07-01

    Although several antibodies are available for immunohistochemical detection of Ki-67, even the most commonly used MIB-1 has not been validated yet. Our aim was to compare 5 commercially available antibodies for detection of Ki-67 in terms of agreement and their ability in predicting prognosis of breast cancer. Tissue microarrays were constructed from 378 breast cancer patients' representative formalin-fixed, paraffin-embedded tumor blocks. Five antibodies were used to detect Ki-67 expression: MIB-1 using chromogenic detection and immunofluorescent-labeled MIB-1, SP-6, 30-9, poly, and B56. Semiquantitative assessment was performed by 2 pathologists independently on digitized slides. To compare the 5 antibodies, intraclass correlation and concordance correlation coefficient were used. All the antibodies but immunofluorescent-labeled MIB-1 (at 20% and 30% thresholds, P=.993 and P=.342, respectively) and B56 (at 30% threshold, P=.288) separated high- and low-risk patient groups. However, there were a significant difference (P values for all comparisons≤.005) and a moderate concordance (intraclass correlation, 0.645) between their Ki-67 labeling index scores. The highest concordance was found between MIB-1 and poly (concordance correlation coefficient=0.785) antibodies. None of the antibodies except Ki-67 labeling index as detected by poly (P=.031) at 20% threshold and lymph node status (P<.001) were significantly linked to disease-free survival in multivariate analysis. At 30% threshold, this was reduced to lymph node status (P<.001) alone. Our results showed that there are considerable differences between the different Ki-67 antibodies in their capacity to detect proliferating tumor cells and to separate low- and high-risk breast cancer patient groups. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. The population biology and genetics of the deep-sea spider crab, Encephaloides armstrongi Wood-Mason 1891 (Decapoda: Majidae)

    PubMed Central

    Creasey, S.; Rogers, A. D.; Tyler, P.; Young, C.; Gage, J.

    1997-01-01

    Numerous specimens of the majid spider crab, Encephaloides armstrongi, were sampled from six stations (populations) between 150 and 650 m depth, on the continental slope off the coast of Oman. This extended the known geographic and bathymetric range of E. armstrongi, which is now known to occur along the continental margins of the northern Indian Ocean from the western coast of Burma to the coast of Oman. This band-like distribution is contiguous to the oxygen minimum zone in this region. The biology and genetics of populations of Encephaloides armstrongi separated by depth were studied. The overall sex ratio of the E. armstrongi sampled was male-biased (p less than 0.01; 3.3 males: 1 female; So = 0.538). However, sex ratio varied both between populations (p less than 0.01) and between size classes of crabs. Size frequency analysis indicated that the male and female crabs consisted of at least two instars, one between 6 and 16mm carapace length and one between 16 and 29 mm carapace length, which probably represented the terminal (pubertal) moult for most individuals. Accumulation of female crabs in the terminal instar probably caused the variation of sex ratio with size classes. Some male crabs grew to a larger size (up to 38 mm carapace length), possibly as a result of maturity at later instars. Length frequency distribution was significantly different between sexes (one-way ANOVA p less than 0.001). Within sexes, length frequency distributions varied between different populations. In both male and female Encephaloides armstrongi the individuals from a single population located at 150 m depth were significantly smaller than individuals at all other stations and were considered to represent a juvenile cohort. For female crabs no other significant differences were detected in length frequency between populations from 300 m to 650 m depth. Significant differences in length frequency were detected between male crabs from populations between 300 and 650 m depth. Horizontal starch gel electrophoresis was used to detect six enzyme systems coding for eight loci for individuals sampled from each population of Encephaloides armstrongi. Genetic identity (I) values between populations of E. armstrongi (I = 0.98-1.00) were within the normal range for conspecific populations. Observed heterozygosity (Ho = 0.080-0.146) was lower than expected heterozygosity (He = 0.111-0.160), but in the normal range detected for eukaryotic organisms. F-statistics were used to analyse between population (FST) and within population (F ) genetic structure. For both male and female E. armstrongi significant genetic differentiation was detected between the population located at 150 m depth and all other populations. Analyses of FIS and FST, excluding the 150 m population indicated that for female E. armstrongi there was no significant structuring within or between populations. For male E. armstrongi significant heterozygote deficiencies were detected within populations and significant genetic differentiation between populations. The most likely explanations for the observations of the present study are: the population of Encephaloides armstrongi located at 150 m depth represented a juvenile cohort that is genetically distinct from deeper populations; female E. armstrongi formed a single population between 300 m and 650 m depth in the sampling area; male E. armstrongi were from two or more genetically distinct populations which are represented by different numbers of individuals at stations between 300 m and 650 m depth. This caused the observed significant differences in morphology (size distribition) and allele frequencies of male populations. It is likely that E. armstrongi exhibits gender-biased dispersal and that the crabs collected between 300 m and 650 m depth formed spawning aggressions. This also explains the bias in sex ratio of individuals sampled in the present study.

  18. Differences in taste detection thresholds between normal-weight and obese young adults.

    PubMed

    Park, Dong Choon; Yeo, Joon Hyung; Ryu, In Yong; Kim, Sang Hoon; Jung, Junyang; Yeo, Seung Geun

    2015-05-01

    Compared with normal-weight individuals, obese young adults exhibited a significantly higher taste threshold for salty taste. Smoking also affected taste functions in this population. The aim of this study was to investigate the differences in taste detection thresholds between normal-weight and obese young adults. Taste threshold was measured using electrogustometry (EGM) and chemically with sucrose, NaCl, citric acid, and quinine hydrochloride in 41 volunteers in their twenties, 23 with body mass index (BMI) <23 kg/m(2) (normal-weight group) and 18 with BMI >25 kg/m(2) (obese group). BMI was significantly higher in the obese than in the normal-weight group (p < 0.05). The obese group exhibited significantly higher EGM thresholds than the normal-weight group on the right (p < 0.05) and left (p < 0.05) posterior tongue. In chemical taste tests, the obese group had higher thresholds for sweet, salty, sour, and bitter tastes than the normal-weight group, although the difference in threshold was significant only for salty taste (p < 0.05). Smoking had an impact on taste threshold, with smokers having higher thresholds than non-smokers, with significantly higher EGM thresholds on the right anterior and posterior and the left anterior tongue (p < 0.05 each).

  19. Detection of major climatic and environmental predictors of liver fluke exposure risk in Ireland using spatial cluster analysis.

    PubMed

    Selemetas, Nikolaos; de Waal, Theo

    2015-04-30

    Fasciolosis caused by Fasciola hepatica (liver fluke) can cause significant economic and production losses in dairy cow farms. The aim of the current study was to identify important weather and environmental predictors of the exposure risk to liver fluke by detecting clusters of fasciolosis in Ireland. During autumn 2012, bulk-tank milk samples from 4365 dairy farms were collected throughout Ireland. Using an in-house antibody-detection ELISA, the analysis of BTM samples showed that 83% (n=3602) of dairy farms had been exposed to liver fluke. The Getis-Ord Gi* statistic identified 74 high-risk and 130 low-risk significant (P<0.01) clusters of fasciolosis. The low-risk clusters were mostly located in the southern regions of Ireland, whereas the high-risk clusters were mainly situated in the western part. Several climatic variables (monthly and seasonal mean rainfall and temperatures, total wet days and rain days) and environmental datasets (soil types, enhanced vegetation index and normalised difference vegetation index) were used to investigate dissimilarities in the exposure to liver fluke between clusters. Rainfall, total wet days and rain days, and soil type were the significant classes of climatic and environmental variables explaining the differences between significant clusters. A discriminant function analysis was used to predict the exposure risk to liver fluke using 80% of data for modelling and the remaining subset of 20% for post hoc model validation. The most significant predictors of the model risk function were total rainfall in August and September and total wet days. The risk model presented 100% sensitivity and 91% specificity and an accuracy of 95% correctly classified cases. A risk map of exposure to liver fluke was constructed with higher probability of exposure in western and north-western regions. The results of this study identified differences between clusters of fasciolosis in Ireland regarding climatic and environmental variables and detected significant predictors of the exposure risk to liver fluke. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Clinical utility of capsule endoscopy with flexible spectral imaging color enhancement for diagnosis of small bowel lesions

    PubMed Central

    Sato, Yasushi; Sagawa, Tamotsu; Hirakawa, Masahiro; Ohnuma, Hiroyuki; Osuga, Takahiro; Okagawa, Yutaka; Tamura, Fumito; Horiguchi, Hiroto; Takada, Kohichi; Hayashi, Tsuyoshi; Sato, Tsutomu; Miyanishi, Koji; Takimoto, Rishu; Kobune, Masayoshi; Kato, Junji

    2014-01-01

    Background and study aims: The clinical utility of computed virtual chromoendoscopy with flexible spectral imaging color enhancement (FICE) in capsule endoscopy (CE) remains controversial. To clarify the clinical utility of FICE-enhanced CE in evaluating small bowel lesions, we quantitatively assessed white light (WL), FICE, and blue mode (BM) images and examined the sensitivity of these 3 imaging modes of small-bowel lesions from patients who underwent CE. Methods: The CIELAB color difference (∆E) and visual analogue scales (VAS) were measured in 261 CE images (3 different lesion categories) using WL and FICE set 1, 2, and 3, and BM images, respectively. Three endoscopists reviewed CE videos with WL, 3 FICE mode settings, and BM, and compared the sensitivity and detectability for small intestinal diseases from 50 patients who underwent CE. Results: In the assessment of visibility in the 152 vascular lesion images, the ∆E and VAS of FICE set 1, 2, and BM images were significantly higher than that of WL images. In 88 erosion/ulceration images, the ∆E and VAS of FICE set 1 and 2 images were significantly higher than that of WL images. In 21 tumor images, there were no significant differences in ∆E among these modalities. When analyzed on a per-patient basis, FICE settings 1 and 2 had the highest sensitivity (100 %) and specificity (97.3 – 100 %) for vascular lesions. As for erosive/ulcerative lesions, FICE setting 2 had the highest sensitivity (100 %) and specificity (97.2 %). For tumors or polyps, WL had the highest sensitivity (90.9 %) and specificity (87.1 %). In per-lesion analysis, FICE settings 1 and 2 showed significantly superior detection ability over WL for vascular lesions. In the detection of erosive/ulcerative lesions, FICE setting 2 was significantly superior to WL. In tumor images, there was no significant improvement with any of the settings relative to WL images. Conclusions: FICE is most useful for improving CE image quality and detection in cases of angioectasia and erosion/ulceration of the small intestine. PMID:26135265

  1. The Impact of a City-Level Minimum-Wage Policy on Supermarket Food Prices in Seattle-King County.

    PubMed

    Otten, Jennifer J; Buszkiewicz, James; Tang, Wesley; Aggarwal, Anju; Long, Mark; Vigdor, Jacob; Drewnowski, Adam

    2017-09-09

    Background : Many states and localities throughout the U.S. have adopted higher minimum wages. Higher labor costs among low-wage food system workers could result in higher food prices. Methods : Using a market basket of 106 foods, food prices were collected at affected chain supermarket stores in Seattle and same-chain unaffected stores in King County (n = 12 total, six per location). Prices were collected at 1 month pre- (March 2015) and 1-month post-policy enactment (May 2015), then again 1-year post-policy enactment (May 2016). Unpaired t-tests were used to detect price differences by location at fixed time while paired t-tests were used to detect price difference across time with fixed store chain. A multi-level, linear differences-in-differences model, was used to detect the changes in the average market basket item food prices over time across regions, overall and by food group. Results : There were no significant differences in overall market basket or item-level costs at one-month (-$0.01, SE = 0.05, p = 0.884) or one-year post-policy enactment (-$0.02, SE = 0.08, p = 0.772). No significant increases were observed by food group. Conclusions : There is no evidence of change in supermarket food prices by market basket or increase in prices by food group in response to the implementation of Seattle's minimum wage ordinance.

  2. Detecting Aspiration and Penetration Using FEES With and Without Food Dye.

    PubMed

    Marvin, Stevie; Gustafson, Sara; Thibeault, Susan

    2016-08-01

    The objective of this investigation was to determine if there were differences in identifying airway invasion (penetration or aspiration) during fiberoptic endoscopic evaluations of swallowing (FEES) for green-dyed versus non-dyed liquids. Forty adult inpatients in an acute care hospital underwent FEES, with both green-dyed liquids and naturally white liquids. Three speech-language pathologists rated aspiration and penetration for trials of nectar-thick milk and thin milk, both with and without green food dye. A subset of participants having excess pharyngeal/laryngeal secretions, as measured by the Secretions Severity Scale, were also analyzed for a difference in the detection of airway invasion and pharyngeal residue. No significant differences were found between dyes in airway invasion across all bolus types within participants. Significant differences were found in penetration ratings for large volumes of thin liquids (90 ml), between participants. When examining only discrepant airway invasion judgments for green-white swallow pairs, statistically significantly deeper airway invasion was measured for green-dyed boluses versus white for three of the five bolus types. Repeat rater reliability was better for dyed versus undyed liquids. Findings suggest that the use of green dye may allow for improved judgment of airway invasion.

  3. Status and effect of pesticide residues in soils under different land uses of Andaman Islands, India.

    PubMed

    Murugan, A V; Swarnam, T P; Gnanasambandan, S

    2013-10-01

    Pesticides are shown to have a great effect on soil organisms, but the effect varies with pesticide group and concentration, and is modified by soil organic carbon content and soil texture. In the humid tropical islands of Andaman, India, no systematic study was carried out on pesticide residues in soils of different land uses. The present study used the modified QuEChERS method for multiresidue extraction from soils and detection with a gas chromatograph. DDT and its various metabolites, α-endosulfan, β-endosulfan, endosulfan sulfate, aldrin, and fenvalerate, were detected from the study area. Among the different pesticide groups detected, endosulfan and DDT accounted for 41.7 % each followed by aldrin (16.7 %) and synthetic pyrethroid (8.3 %). A significantly higher concentration of pesticide residues was detected in rice-vegetable grown in the valley followed by rice-fallow and vegetable-fallow in the coastal plains. Soil microbial biomass carbon is negatively correlated with the total pesticide residues in soils, and it varied from 181.2 to 350.6 mg kg(-1). Pesticide residues have adversely affected the soil microbial populations, more significantly the bacterial population. The Azotobacter population has decreased to the extent of 51.8 % while actinomycetes were the least affected though accounted for 32 % when compared to the soils with no residue.

  4. How quickly do breast screeners learn their skills?

    NASA Astrophysics Data System (ADS)

    Nevisi, Hossein; Dong, Leng; Chen, Yan; Gale, Alastair G.

    2017-03-01

    The UK's Breast Screening Programme is 27 years old and many experienced breast radiologists are now retiring, coupled with an influx of new screening personnel. It is important to the ongoing Programme that new mammography readers are quickly up to the skill level of experienced readers. This raises the question of how quickly the necessary cancer detection skills are learnt. All breast screening radiologists in the UK read educational training sets of challenging FFDM images (the PERFORMS® scheme) yearly to maintain and improve their performance in real life screening. Data were examined from the PERFORMS® annual scheme for 54 new screeners, 55 screeners who have been screening for one year and also for more experienced screeners (597 screeners). Not surprisingly, significant differences in cancer detection rate were found between new readers and both of the other groups. Additionally, the performance of 48 new readers who have now been screening for about a year and have taken part twice in the PERFORMS® scheme were further examined where again a significant difference in cancer detection was found. These data imply that cancer detection skills are learnt quickly in the first year of screening. Information was also examined concerning the volume of cases participants read and other factors.

  5. Using Renyi entropy to detect early cardiac autonomic neuropathy.

    PubMed

    Cornforth, David J; Tarvainen, Mika P; Jelinek, Herbert F

    2013-01-01

    Cardiac Autonomic Neuropathy (CAN) is a disease that involves nerve damage leading to abnormal control of heart rate. CAN affects the correct operation of the heart and in turn leads to associated arrhythmias and heart attack. An open question is to what extent this condition is detectable by the measurement of Heart Rate Variability (HRV). An even more desirable option is to detect CAN in its early, preclinical stage, to improve treatment and outcomes. In previous work we have shown a difference in the Renyi spectrum between participants identified with well-defined CAN and controls. In this work we applied the multi-scale Renyi entropy for identification of early CAN in diabetes patients. Results suggest that Renyi entropy derived from a 20 minute, Lead-II ECG recording, forms a useful contribution to the detection of CAN even in the early stages of the disease. The positive α parameters (1 ≤ α ≤ 5) associated with the Renyi distribution indicated a significant difference (p < 0.00004) between controls and early CAN as well as definite CAN. This is a significant achievement given the simple nature of the information collected, and raises prospects of a simple screening test and improved outcomes of patients.

  6. Effect of gap detection threshold on consistency of speech in children with speech sound disorder.

    PubMed

    Sayyahi, Fateme; Soleymani, Zahra; Akbari, Mohammad; Bijankhan, Mahmood; Dolatshahi, Behrooz

    2017-02-01

    The present study examined the relationship between gap detection threshold and speech error consistency in children with speech sound disorder. The participants were children five to six years of age who were categorized into three groups of typical speech, consistent speech disorder (CSD) and inconsistent speech disorder (ISD).The phonetic gap detection threshold test was used for this study, which is a valid test comprised six syllables with inter-stimulus intervals between 20-300ms. The participants were asked to listen to the recorded stimuli three times and indicate whether they heard one or two sounds. There was no significant difference between the typical and CSD groups (p=0.55), but there were significant differences in performance between the ISD and CSD groups and the ISD and typical groups (p=0.00). The ISD group discriminated between speech sounds at a higher threshold. Children with inconsistent speech errors could not distinguish speech sounds during time-limited phonetic discrimination. It is suggested that inconsistency in speech is a representation of inconsistency in auditory perception, which causes by high gap detection threshold. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. A photonic crystal hydrogel suspension array for the capture of blood cells from whole blood

    NASA Astrophysics Data System (ADS)

    Zhang, Bin; Cai, Yunlang; Shang, Luoran; Wang, Huan; Cheng, Yao; Rong, Fei; Gu, Zhongze; Zhao, Yuanjin

    2016-02-01

    Diagnosing hematological disorders based on the separation and detection of cells in the patient's blood is a significant challenge. We have developed a novel barcode particle-based suspension array that can simultaneously capture and detect multiple types of blood cells. The barcode particles are polyacrylamide (PAAm) hydrogel inverse opal microcarriers with characteristic reflection peak codes that remain stable during cell capture on their surfaces. The hydrophilic PAAm hydrogel scaffolds of the barcode particles can entrap various plasma proteins to capture different cells in the blood, with little damage to captured cells.Diagnosing hematological disorders based on the separation and detection of cells in the patient's blood is a significant challenge. We have developed a novel barcode particle-based suspension array that can simultaneously capture and detect multiple types of blood cells. The barcode particles are polyacrylamide (PAAm) hydrogel inverse opal microcarriers with characteristic reflection peak codes that remain stable during cell capture on their surfaces. The hydrophilic PAAm hydrogel scaffolds of the barcode particles can entrap various plasma proteins to capture different cells in the blood, with little damage to captured cells. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06368j

  8. Automatic Detection of Lung and Liver Lesions in 3-D Positron Emission Tomography Images: A Pilot Study

    NASA Astrophysics Data System (ADS)

    Lartizien, Carole; Marache-Francisco, Simon; Prost, Rémy

    2012-02-01

    Positron emission tomography (PET) using fluorine-18 deoxyglucose (18F-FDG) has become an increasingly recommended tool in clinical whole-body oncology imaging for the detection, diagnosis, and follow-up of many cancers. One way to improve the diagnostic utility of PET oncology imaging is to assist physicians facing difficult cases of residual or low-contrast lesions. This study aimed at evaluating different schemes of computer-aided detection (CADe) systems for the guided detection and localization of small and low-contrast lesions in PET. These systems are based on two supervised classifiers, linear discriminant analysis (LDA) and the nonlinear support vector machine (SVM). The image feature sets that serve as input data consisted of the coefficients of an undecimated wavelet transform. An optimization study was conducted to select the best combination of parameters for both the SVM and the LDA. Different false-positive reduction (FPR) methods were evaluated to reduce the number of false-positive detections per image (FPI). This includes the removal of small detected clusters and the combination of the LDA and SVM detection maps. The different CAD schemes were trained and evaluated based on a simulated whole-body PET image database containing 250 abnormal cases with 1230 lesions and 250 normal cases with no lesion. The detection performance was measured on a separate series of 25 testing images with 131 lesions. The combination of the LDA and SVM score maps was shown to produce very encouraging detection performance for both the lung lesions, with 91% sensitivity and 18 FPIs, and the liver lesions, with 94% sensitivity and 10 FPIs. Comparison with human performance indicated that the different CAD schemes significantly outperformed human detection sensitivities, especially regarding the low-contrast lesions.

  9. Protein detection through different platforms of immuno-loop-mediated isothermal amplification

    NASA Astrophysics Data System (ADS)

    Pourhassan-Moghaddam, Mohammad; Rahmati-Yamchi, Mohammad; Akbarzadeh, Abolfazl; Daraee, Hadis; Nejati-Koshki, Kazem; Hanifehpour, Younes; Joo, Sang Woo

    2013-11-01

    Different immunoassay-based methods have been devised to detect protein targets. These methods have some challenges that make them inefficient for assaying ultra-low-amounted proteins. ELISA, iPCR, iRCA, and iNASBA are the common immunoassay-based methods of protein detection, each of which has specific and common technical challenges making it necessary to introduce a novel method in order to avoid their problems for detection of target proteins. Here we propose a new method nominated as `immuno-loop-mediated isothermal amplification' or `iLAMP'. This new method is free from the problems of the previous methods and has significant advantages over them. In this paper we also offer various configurations in order to improve the applicability of this method in real-world sample analyses. Important potential applications of this method are stated as well.

  10. Real-time detection of deoxyribonucleic acid bases via their negative differential conductance signature.

    PubMed

    Dragoman, D; Dragoman, M

    2009-08-01

    In this Brief Report, we present a method for the real-time detection of the bases of the deoxyribonucleic acid using their signatures in negative differential conductance measurements. The present methods of electronic detection of deoxyribonucleic acid bases are based on a statistical analysis because the electrical currents of the four bases are weak and do not differ significantly from one base to another. In contrast, we analyze a device that combines the accumulated knowledge in nanopore and scanning tunneling detection and which is able to provide very distinctive electronic signatures for the four bases.

  11. B-Spline Filtering for Automatic Detection of Calcification Lesions in Mammograms

    NASA Astrophysics Data System (ADS)

    Bueno, G.; Sánchez, S.; Ruiz, M.

    2006-10-01

    Breast cancer continues to be an important health problem between women population. Early detection is the only way to improve breast cancer prognosis and significantly reduce women mortality. It is by using CAD systems that radiologist can improve their ability to detect, and classify lesions in mammograms. In this study the usefulness of using B-spline based on a gradient scheme and compared to wavelet and adaptative filtering has been investigated for calcification lesion detection and as part of CAD systems. The technique has been applied to different density tissues. A qualitative validation shows the success of the method.

  12. Pulmonary nodule detection in oncological patients - Value of respiratory-triggered, periodically rotated overlapping parallel T2-weighted imaging evaluated with PET/CT-MR.

    PubMed

    de Galiza Barbosa, Felipe; Geismar, Jan Henning; Delso, Gaspar; Messerli, Michael; Huellner, Martin; Stolzmann, Paul; Veit-Haibach, Patrick

    2018-01-01

    To prospectively evaluate the detection and conspicuity of pulmonary nodules in an oncological population, using a tri-modality PET/CT-MR protocol including a respiration-gated T2-PROPELLER sequence for possible integration into a simultaneous PET/MR protocol. 149 patients referred for staging of malignancy were prospectively enrolled in this single-center study. Imaging was performed on a tri-modality PET/CT-MR setup and was comprised of PET/CT and 3T-MR imaging with 3D dual-echo GRE pulse sequence (Dixon) and an axial respiration-gated T2-weighted PROPELLER (T2-P) sequence. Images were assessed for presence, conspicuity, size and interpretation of the pulmonary parenchymal nodules. McNemar's test was used to evaluate paired differences in nodule detection rates between MR and CT from PET/CT. The correlation of pulmonary nodule size in CT and MR imaging was assessed using Pearson correlation coefficient. 299 pulmonary nodules were detected on PET/CT. The detectability was significantly higher on T2-P (60%, p<0.01) compared to T1-weighted Dixon-type sequences (16.1-37.8%). T2-P had a significantly higher detection rate among FDG-positive (92.4%) and among confirmed malignant nodules (75.9%) compared to T1-Dixon. Nodules <10mm were detected less often by MR sequences than by CT (p < 0.01). However, nodules >10mm were detected equally well with T2-P (92.2%) and CT (p >0.05). In a per-patient analysis, there was no significant change in the clinical interpretation of the nodules detected with T2-P and CT. Despite the overall lower detection rate compared with CT, the free-breathing respiratory gating T2-w sequence showed higher detectability in all evaluated categories compared to breath-hold T1-weighted MR sequences. Specifically, the T2-P was found to be not statistically different from CT in FDG-positive nodules, in detection of nodules >10mm and concerning conspicuity of pulmonary nodules. Overall, the additional time investment into T2-P seems to be justified since clinical relevant assessment of pulmonary lung nodules can mostly be done by T2-P in a whole body PET/MR staging of oncologic patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Evaluation of chest tomosynthesis for the detection of pulmonary nodules: effect of clinical experience and comparison with chest radiography

    NASA Astrophysics Data System (ADS)

    Zachrisson, Sara; Vikgren, Jenny; Svalkvist, Angelica; Johnsson, Åse A.; Boijsen, Marianne; Flinck, Agneta; Månsson, Lars Gunnar; Kheddache, Susanne; Båth, Magnus

    2009-02-01

    Chest tomosynthesis refers to the technique of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest. In this study, a comparison of chest tomosynthesis and chest radiography in the detection of pulmonary nodules was performed and the effect of clinical experience of chest tomosynthesis was evaluated. Three senior thoracic radiologists, with more than ten years of experience of chest radiology and 6 months of clinical experience of chest tomosynthesis, acted as observers in a jackknife free-response receiver operating characteristics (JAFROC-1) study, performed on 42 patients with and 47 patients without pulmonary nodules examined with both chest tomosynthesis and chest radiography. MDCT was used as reference and the total number of nodules found using MDCT was 131. To investigate the effect of additional clinical experience of chest tomosynthesis, a second reading session of the tomosynthesis images was performed one year after the initial one. The JAFROC-1 figure of merit (FOM) was used as the principal measure of detectability. In comparison with chest radiography, chest tomosynthesis performed significantly better with regard to detectability. The observer-averaged JAFROC-1 FOM was 0.61 for tomosynthesis and 0.40 for radiography, giving a statistically significant difference between the techniques of 0.21 (p<0.0001). The observer-averaged JAFROC-1 FOM of the second reading of the tomosynthesis cases was not significantly higher than that of the first reading, indicating no improvement in detectability due to additional clinical experience of tomosynthesis.

  14. Bayesian longitudinal segmentation of hippocampal substructures in brain MRI using subject-specific atlases.

    PubMed

    Iglesias, Juan Eugenio; Van Leemput, Koen; Augustinack, Jean; Insausti, Ricardo; Fischl, Bruce; Reuter, Martin

    2016-11-01

    The hippocampal formation is a complex, heterogeneous structure that consists of a number of distinct, interacting subregions. Atrophy of these subregions is implied in a variety of neurodegenerative diseases, most prominently in Alzheimer's disease (AD). Thanks to the increasing resolution of MR images and computational atlases, automatic segmentation of hippocampal subregions is becoming feasible in MRI scans. Here we introduce a generative model for dedicated longitudinal segmentation that relies on subject-specific atlases. The segmentations of the scans at the different time points are jointly computed using Bayesian inference. All time points are treated the same to avoid processing bias. We evaluate this approach using over 4700 scans from two publicly available datasets (ADNI and MIRIAD). In test-retest reliability experiments, the proposed method yielded significantly lower volume differences and significantly higher Dice overlaps than the cross-sectional approach for nearly every subregion (average across subregions: 4.5% vs. 6.5%, Dice overlap: 81.8% vs. 75.4%). The longitudinal algorithm also demonstrated increased sensitivity to group differences: in MIRIAD (69 subjects: 46 with AD and 23 controls), it found differences in atrophy rates between AD and controls that the cross sectional method could not detect in a number of subregions: right parasubiculum, left and right presubiculum, right subiculum, left dentate gyrus, left CA4, left HATA and right tail. In ADNI (836 subjects: 369 with AD, 215 with early cognitive impairment - eMCI - and 252 controls), all methods found significant differences between AD and controls, but the proposed longitudinal algorithm detected differences between controls and eMCI and differences between eMCI and AD that the cross sectional method could not find: left presubiculum, right subiculum, left and right parasubiculum, left and right HATA. Moreover, many of the differences that the cross-sectional method already found were detected with higher significance. The presented algorithm will be made available as part of the open-source neuroimaging package FreeSurfer. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  15. The Reverberation Lag in the Low-mass X-ray Binary H1743-322

    NASA Astrophysics Data System (ADS)

    De Marco, Barbara; Ponti, Gabriele

    2016-07-01

    The evolution of the inner accretion flow of a black hole X-ray binary during an outburst is still a matter of active research. X-ray reverberation lags are powerful tools for constraining disk-corona geometry. We present a study of X-ray lags in the black hole transient H1743-322. We compared the results obtained from analysis of all the publicly available XMM-Newton observations. These observations were carried out during two different outbursts that occurred in 2008 and 2014. During all the observations the source was caught in the hard state and at similar luminosities ({L}3-10{keV}/{L}{Edd}˜ 0.004). We detected a soft X-ray lag of ˜60 ms, most likely due to thermal reverberation. We did not detect any significant change of the lag amplitude among the different observations, indicating a similar disk-corona geometry at the same luminosity in the hard state. On the other hand, we observe significant differences between the reverberation lag detected in H1743-322 and in GX 339-4 (at similar luminosities in the hard state), which might indicate variations of the geometry from source to source.

  16. [Investigation of norovirus infection incidence among 0-5 years old children with acute gastroenteritis admitted to two different hospitals in ankara, Turkey].

    PubMed

    Altay, Aylin; Bozdayı, Gülendam; Meral, Melda; Dallar Bilge, Yıldız; Dalgıç, Buket; Ozkan, Seçil; Ahmed, Kamruddin

    2013-01-01

    Norovirus causes severe gastroenteritis requiring hospitalization especially in children less than five years of age both in developed and developing countries. Therefore, we aimed to investigate the incidence of norovirus (NoV) in 0-5 years old children with acute gastroenteritis in two large hospitals in Ankara, Turkey. Stool samples were obtained from 1000 (413 female, 587 male) children between 0-5 years old with acute gastroenteritis who attended to the Department of Paediatrics, Ministry of Health Ankara Training and Education Hospital and affiliated hospital of Gazi University Faculty of Medicine between October 2004 and June 2011. Antigens of norovirus GI and GII genogroups in the stool specimens were detected by ELISA (RIDASCREEN® Norovirus (C1401) 3rd Generation, R-Biopharm, Germany). Norovirus GI and GII antigens were determined in a total of 141 (14.1%) samples, of them 62 (15%) were female and 79 (13.5%) were male, yielding no statistically significant difference (p> 0.05). The highest NoV positivity was detected in children between 12-23 months (17.1%), however there was no statistically significant difference between ELISA positivity and age (p> 0.05). NoV detection rate was highest in 2007 (18.4%) and in 2009 (18%), and the difference regarding ELISA positivity among the study years was not statistically significant (p> 0.05). The prevalences of norovirus infection in spring, summer, autumn and winter were 13.8%, 17.7%, 14.7% and 11.2%, respectively. Therefore no seasonal variation was found in the incidence of norovirus infection. However when the monthly prevalence was analyzed, a statistically significant difference was found (p< 0.05) between the rate of norovirus infection in july (24.2%) and december (4.1%). When evaluating the clinical symptoms, all of 141 patients (100%) had diarrhoea, while 72 (51.1%) had vomiting. Stool samples were also evaluated for the presence of parasitic and bacterial agents. Coinfection rate with parasites was detected as 3.3% (4/122; norovirus + Entamoeba histolytica in three cases, norovirus + Enterobius vermicularis in one case), while no pathogenic bacteria were isolated from norovirus positive stool samples. The prevalence rate of 14.1% for NoV GI/GII infection detected in this retrospective study including 0-5 years old children in Ankara for 2004-2011 period was thought to reflect the regional data and would contribute to national epidemiological data. We anticipate that the incidence of norovirus will increase in 0-5 year old children as a result of increasing use of rotavirus vaccine in Turkish children. It was concluded that, NoV antigen detection tests should be used in routine laboratories for appropriate diagnosis of sporadic and/or epidemic norovirus infections.

  17. MR Spectroscopy to Distinguish between Supratentorial Intraventricular Subependymoma and Central Neurocytoma.

    PubMed

    Ueda, Fumiaki; Aburano, Hiroyuki; Ryu, Yasuji; Yoshie, Yuichi; Nakada, Mitsutoshi; Hayashi, Yutaka; Matsui, Osamu; Gabata, Toshifumi

    2017-07-10

    The purpose of this study was to discriminate supratentorial intraventricular subependymoma (SIS) from central neurocytoma (CNC) using magnetic resonance spectroscopy (MRS). Single-voxel proton MRS using a 1.5T or 3T MR scanner from five SISs, five CNCs, and normal controls were evaluated. They were examined using a point-resolved spectroscopy. Automatically calculated ratios comparing choline (Cho), N-acetylaspartate (NAA), myoinositol (MI), and/or glycine (Gly) to creatine (Cr) were determined. Evaluation of Cr to unsuppressed water (USW) was also performed. Mann-Whitney U test was carried out to test the significance of differences in the metabolite ratios. Detectability of lactate (Lac) and alanine (Ala) was evaluated. Although a statistically significant difference (P < 0.0001) was observed in Cho/Cr among SIS, control spectra, and CNC, no statistical difference was noted between SIS and control spectra (P = 0.11). Statistically significant differences were observed in NAA/Cr between SIS and CNC (P = 0.04) or control spectra (P < 0.0001). A statistically significant difference was observed in MI and/or Gly to Cr between SIS and control spectra (P = 0.03), and CNC and control spectra (P < 0.0006). There were no statistical differences between SIS and CNC for MI and/or Gly to Cr (P = 0.32). Significant statistical differences were found between SIS and control spectra (P < 0.0053), control spectra and CNC (P < 0.0016), and SIS and CNC (P < 0.0083) for Cr to USW. Lac inverted doublets were confirmed in two SISs. Triplets of Lac and Ala were detected in four spectra of CNC. The present study showed that MRS can be useful in discriminating SIS from CNC.

  18. Ketamine added to morphine or hydromorphone patient-controlled analgesia for acute postoperative pain in adults: a systematic review and meta-analysis of randomized trials.

    PubMed

    Wang, Li; Johnston, Bradley; Kaushal, Alka; Cheng, Davy; Zhu, Fang; Martin, Janet

    2016-03-01

    To determine whether ketamine added to morphine or hydromorphone patient-controlled analgesia (PCA) provides clinically relevant reductions in postoperative pain, opioid requirements, and adverse events when compared with morphine or hydromorphone PCA in adults undergoing surgery. We systematically searched six databases up to June 2, 2015 for randomized controlled trials (RCTs) comparing ketamine plus morphine/hydromorphone PCA vs morphine/hydromorphone PCA for postoperative pain in adults. Thirty-six RCTs including 2,502 patients proved eligible, and 22 of these were at low risk of bias. The addition of ketamine to morphine/hydromorphone PCA decreased postoperative pain intensity at six to 72 hr when measured at rest (weighted mean difference [WMD] on a 10-cm visual analogue scale ranged from -0.4 to -1.3 cm) and during mobilization (WMD ranged from -0.4 to -0.5 cm). Adjunctive ketamine also significantly reduced cumulative morphine consumption at 24-72 hr by approximately 5-20 mg. Predefined subgroup analyses and meta-regression did not detect significant differences across subgroups, including a dose-response relationship. There was no significant difference in patient satisfaction scores at 24 and 48 hr. Nevertheless, the addition of ketamine to morphine/hydromorphone PCA significantly reduced postoperative nausea and vomiting (relative risk, 0.71; 95% confidence interval [CI], 0.60 to 0.85; absolute risk reduction, 8.9%; 95% CI, 4.6 to 12.2). Significant effects on other adverse events (e.g., hallucinations, vivid dreams) were not detected, though only a few studies reported on them. Adding ketamine to morphine/hydromorphone PCA provides a small improvement in postoperative analgesia while reducing opioid requirements. Adjunctive ketamine also reduces postoperative nausea and vomiting without a detected increase in other adverse effects; however, adverse events were probably underreported.

  19. Influence of dual-tasking with different levels of attention diversion on characteristics of the movement-related cortical potential.

    PubMed

    Aliakbaryhosseinabadi, Susan; Kamavuako, Ernest Nlandu; Jiang, Ning; Farina, Dario; Mrachacz-Kersting, Natalie

    2017-11-01

    Dual tasking is defined as performing two tasks concurrently and has been shown to have a significant effect on attention directed to the performance of the main task. In this study, an attention diversion task with two different levels was administered while participants had to complete a cue-based motor task consisting of foot dorsiflexion. An auditory oddball task with two levels of complexity was implemented to divert the user's attention. Electroencephalographic (EEG) recordings were made from nine single channels. Event-related potentials (ERPs) confirmed that the oddball task of counting a sequence of two tones decreased the auditory P300 amplitude more than the oddball task of counting one target tone among three different tones. Pre-movement features quantified from the movement-related cortical potential (MRCP) were changed significantly between single and dual-task conditions in motor and fronto-central channels. There was a significant delay in movement detection for the case of single tone counting in two motor channels only (237.1-247.4ms). For the task of sequence counting, motor cortex and frontal channels showed a significant delay in MRCP detection (232.1-250.5ms). This study investigated the effect of attention diversion in dual-task conditions by analysing both ERPs and MRCPs in single channels. The higher attention diversion lead to a significant reduction in specific MRCP features of the motor task. These results suggest that attention division in dual-tasking situations plays an important role in movement execution and detection. This has important implications in designing real-time brain-computer interface systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. The impact of diet liberalization on bowel preparation for colonoscopy.

    PubMed

    Walter, James; Francis, Gloria; Matro, Rebecca; Kedika, Ramalinga; Grosso, Rachael; Keith, Scott W; Kastenberg, David

    2017-04-01

    Background and study aims  Dietary restrictions are integral to colonoscopy preparation and impact patient satisfaction. Utilizing split-dose, lower-volume polyethylene glycol 3350-electrolyte solution (PEG-ELS), this study compared colon preparation adequacy of a low-residue diet to clear liquids using a validated grading scale. Patients and methods  This was a prospective, randomized, single-blinded, single-center non-inferiority study evaluating diet the day prior to outpatient colonoscopy. Subjects were randomized to a Low-Residue diet for breakfast and lunch, or Clears only. All subjects received split dose PEG-ELS. The primary endpoint was preparation adequacy using the Boston Bowel Preparation Scale (BBPS), with adequate defined as a score > 5. Secondary endpoints included mean BBPS scores for the entire colon and individual segments, satisfaction, adverse events, polyp and adenoma detection rates, and impact on sleep and daily activities. Results  Final analysis included 140 subjects, 72 assigned to Clears and 68 to Low-Residue. The Low-Residue diet was non-inferior to Clears (risk difference = - 5.08 %, P  = 0.04) after adjusting for age. Mean colon cleansing scores were not significantly different overall and for individual colonic segments. Satisfaction with the Low-Residue diet was significantly greater ( P  = 0.01). The adenoma detection rate was not statistically significantly different between study groups, but the number of adenomas detected was significantly greater with Clears ( P  = 0.01). Adverse events and impact on sleep and activities did not differ significantly between diet arms. Conclusions  A low-residue diet for breakfast and lunch the day prior to colonoscopy was non-inferior to clear liquids alone for achieving adequate colon cleansing when using split dose PEG-ELS.

  1. Stability of hemostatic proteins in canine fresh-frozen plasma thawed with a modified commercial microwave warmer or warm water bath.

    PubMed

    Pashmakova, Medora B; Barr, James W; Bishop, Micah A

    2015-05-01

    To compare stability of hemostatic proteins in canine fresh-frozen plasma (FFP) thawed with a modified commercial microwave warmer (MCM) or warm water bath (37°C; WWB) or at room temperature (22°C). Fresh-frozen plasma obtained from 8 canine donors of a commercial blood bank. A commercial microwave warmer was modified with a thermocouple to measure surface temperature of bags containing plasma. The MCM and a WWB were each used to concurrently thaw a 60-mL bag of plasma obtained from the same donor. Two 3-mL control aliquots of FFP from each donor were thawed to room temperature without use of a heating device. Concentrations of hemostatic proteins, albumin, and D-dimers; prothrombin time (PT); and activated partial thromboplastin time (aPTT) were determined for all samples. Significant decreases in concentrations of factors II, IX, X, XI, fibrinogen, von Willebrand factor, antithrombin, protein C, and albumin and significant increases in PT and aPTT were detected for plasma thawed with the MCM, compared with results for samples thawed with the WWB. Concentrations of factors VII, VIII, and XII were not significantly different between plasma thawed with the MCM and WWB. Concentrations of D-dimers were above the reference range for all thawed samples regardless of thawing method. No significant differences in factor concentrations were detected between control and WWB-thawed samples. Significant differences in hemostatic protein concentrations and coagulation times were detected for plasma thawed with an MCM but not between control and WWB-thawed samples. Clinical importance of these changes should be investigated.

  2. Evaluation of hemifield sector analysis protocol in multifocal visual evoked potential objective perimetry for the diagnosis and early detection of glaucomatous field defects.

    PubMed

    Mousa, Mohammad F; Cubbidge, Robert P; Al-Mansouri, Fatima; Bener, Abdulbari

    2014-02-01

    Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.

  3. Evaluation of Hemifield Sector Analysis Protocol in Multifocal Visual Evoked Potential Objective Perimetry for the Diagnosis and Early Detection of Glaucomatous Field Defects

    PubMed Central

    Mousa, Mohammad F.; Cubbidge, Robert P.; Al-Mansouri, Fatima

    2014-01-01

    Purpose Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Methods Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Results Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. Conclusions The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PMID:24511212

  4. [New classification of Crowe type IV developmental dysplasia of the hip].

    PubMed

    Ma, Hai-yang; Zhou, Yong-gang; Zheng, Chong; Cao, Wen-zhe; Wang Sen; Wu, Wen-ming; Piao, Shang; Du, Yin-qiao

    2016-02-01

    To compare differences between Crowe IV developmental dysplasia of the hip (DDH) with secondary acetabulum and Crowe IV DDH without secondary acetabulum,and determine whether it is necessary to divide Crowe IV DDH into two subtypes. From June 2007 to May 2015,145 hips of 112 Crowe N patients who underwent total hip arthroplasty (THA) using S-ROM stem were divided into two groups: secondary acetabulum formaton group (group A) and no secondary acetabulum formaton group (group B). In group A,there were 12 females, 96 males,with an average age of (39.38 ± 11.19) years old. In group B, there were 2 females, 35 males, with an average age of (38.19 ± 10.92) years old. All the patients were evaluated by using Harris Hip Score. Radiographic evaluations were made preoperatively and during follow up. The differences between two groups were compared on dislocation height, canal flare index (CFI), subtrochanteric shortening osteotomy (SSTO) usage, pre- and post-operation Harris scores, complications. The dislocation height for group A was (4.74 ± 1.57) cm, while the dislocation height for group B was (3.12 ± 1.15) cm. Significantly difference was detected between two groups. The CFI for group A was 2.69 ± 0.68, while the CFI for group B was 3.42 ± 0.79, and the significantly difference was detected between two groups. Harris scores were totally improved from 58.18 ± 15.67 preoperatively to 91.20 ± 3.79 post-operatively and the difference was significant. Pre-operative Harris scores was 58.1 ± 15.3 in group A, 58.3 ± 16.9 in group B. Post-operative Harris scores was 91.0 ± 4.1 in group A, 91.0 ± 5.1 in group B. No significant difference was found on Harris scores between A and B preoperatively and post-operatively. Complications of 4 cases peri-prosthesis fracture, 4 cases dislocation and 4 cases nerve injury occur in group A; While only one case dislocation and one case nerve injury occur in group B. No statistical significance was detected. Crowe IV DDH with secondary acetabulum is significantly different from Crowe IV DDH without secondary acetabulum on dislocation height and femoral morphology, which causes the different selections of surgical techniques (SSTO usage or not). These important differences in fundamental parameters indicate the necessity to further divide Crowe IV DDH into IVA and IVB two subtypes.

  5. Acoustic Analysis and Electroglottography in Elite Vocal Performers.

    PubMed

    Villafuerte-Gonzalez, Rocio; Valadez-Jimenez, Victor M; Sierra-Ramirez, Jose A; Ysunza, Pablo Antonio; Chavarria-Villafuerte, Karen; Hernandez-Lopez, Xochiquetzal

    2017-05-01

    Acoustic analysis of voice (AAV) and electroglottography (EGG) have been used for assessing vocal quality in patients with voice disorders. The effectiveness of these procedures for detecting mild disturbances in vocal quality in elite vocal performers has been controversial. To compare acoustic parameters obtained by AAV and EGG before and after vocal training to determine the effectiveness of these procedures for detecting vocal improvements in elite vocal performers. Thirty-three elite vocal performers were studied. The study group included 14 males and 19 females, ages 18-40 years, without a history of voice disorders. Acoustic parameters were obtained through AAV and EGG before and after vocal training using the Linklater method. Nonsignificant differences (P > 0.05) were found between values of fundamental frequency (F 0 ), shimmer, and jitter obtained by both procedures before vocal training. Mean F 0 was similar after vocal training. Jitter percentage as measured by AAV showed nonsignificant differences (P > 0.05) before and after vocal training. Shimmer percentage as measured by AAV demonstrated a significant reduction (P < 0.05) after vocal training. As measured by EGG after vocal training, shimmer and jitter were significantly reduced (P < 0.05); open quotient was significantly increased (P < 0.05); and irregularity was significantly reduced (P < 0.05). AAV and EGG were effective for detecting improvements in vocal function after vocal training in male and female elite vocal performers undergoing vocal training. EGG demonstrated better efficacy for detecting improvements and provided additional parameters as compared to AAV. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  6. [Evaluation of diabetic microangiopathy using optical coherence tomography angiography].

    PubMed

    Czakó, Cecília; Sándor, Gábor László; Ecsedy, Mónika; Szepessy, Zsuzsanna; Borbándy, Ágnes; Resch, Miklós; Papp, András; Récsán, Zsuzsa; Horváth, Hajnalka; Nagy, Zoltán Zsolt; Kovács, Illés

    2018-02-01

    Optical coherence tomography angiography is a non-invasive imaging technique that is able to visualize the different retinal vascular layers using motion contrast to detect blood flow without intravenous dye injection. This method might help to assess microangiopathy in diabetic retinopathy during screening and follow-up. To quantify retinal microvasculature alterations in both eyes of diabetic patients in relation to systemic risk factors using optical coherence tomography angiography. Both eyes of 36 diabetic patients and 45 individuals without diabetes were examined. Duration of diabetes, insulin therapy, blood pressure, HbA 1c , dyslipidemia, axial length and the presence of diabetic retinopathy were recorded. Retinal vessel density was measured by optical coherence tomography angiography. The effect of risk factors on vessel density and between-eye asymmetry was assessed using multivariable regression analysis. Vessel density was significantly lower and between-eye difference was significantly higher in diabetic patients compared to controls (p<0.05). Both vessel density and between-eye asymmetry significantly correlated with diabetes duration (p<0.05) after controlling for the effect of risk factors. The between-eye asymmetry in vessel density was significantly higher in patients without clinically detectable diabetic retinopathy compared to control subjects (p<0.001). There is a decrease in retinal vessel density and an increase in between-eye asymmetry in patients with diabetes compared to healthy subjects. By using optical coherence tomography angiography, the detection of these microvascular alterations is possible before clinically detectable diabetic retinopathy and might serve as a useful tool in both screening and timing of treatment. Orv Hetil. 2018; 159(8): 320-326.

  7. [Virus detection, clinical signs, and laboratory findings in dogs with acute hemorrhagic diarrhea: a retrospective study of 935 cases].

    PubMed

    Kempf, C; Schulz, B S; Strauch, C; Sauter-Louis, C; Truyen, U; Hartmann, K

    2010-01-01

    The study evaluated which viruses can be detected in dogs with acute hemorrhagic diarrhea and compared signalment, clinical signs, and laboratory abnormalities among groups of dogs infected with different viruses and those that tested virus-negative. Fecal samples from 935 dogs with acute hemorrhagic diarrhea were examined by electron microscopy. The medical records of these patients were retrospectively evaluated for clinical and laboratory parameters. Virus was detected in 44.2% of the dogs presented with acute bloody diarrhea. The highest prevalence for a virus infection was demonstrated for canine parvovirus (19.9%), followed by coronavirus (17.3%), and paramyxovirus (13.9%). More than one virus species was detected in 6.5% of all fecal samples. Dogs with a virus-positive fecal sample were significantly younger than dogs that tested negative on electron microscopy. Among virus-positive dogs, dogs with parvovirus infection were significantly younger when compared to dogs infected with other enteric viruses. Parvovirus-infected patients also showed significantly lower leukocyte and erythrocyte counts as well as hematocrit, total protein, and albumin levels compared to all other groups. No significant differences were seen when evaluating sex, clinical parameters, character of diarrhea or vomiting among all groups. Young dogs are more likely to suffer from viral enteritis. Based on clinical parameters it is not possible to differentiate a virus-positive from a virus-negative dog or to diagnose a certain virus species. Besides the young age, parvovirus infection is associated with typical changes in laboratory parameters, but not with specific clinical signs. A virologic fecal examination is always indicated.

  8. Which insulin resistance-based definition of metabolic syndrome has superior diagnostic value in detection of poor health-related quality of life? Cross-sectional findings from Tehran Lipid and Glucose Study.

    PubMed

    Deihim, Tina; Amiri, Parisa; Taherian, Reza; Tohidi, Maryam; Ghasemi, Asghar; Cheraghi, Leila; Azizi, Fereidoun

    2015-12-09

    The superiority of the diagnostic power of different definitions of metabolic syndrome (MetS) in detecting objective and subjective cardiovascular outcomes is under debate. We sought to compare diagnostic values of different insulin resistance (IR)-based definitions of MetS in detecting poor health-related quality of life (HRQoL) in a large sample of Tehranian adults. This cross-sectional study conducted within the framework of the Tehran Lipid and Glucose Study on a total sample of 742 individuals, aged ≥ 20 years. Metabolic syndrome was defined according to the World Health Organization (WHO), the European Group for the study of Insulin Resistance (EGIR), and the American Association of Clinical Endocrinology (AACE). Health-related quality of life was assessed using the Short Form Health Survey (SF-36). Logistic regression analysis and Receiver Operating Characteristic (ROC) curve were used to investigate the impact of the three IR-based definitions of MetS on HRQoL and compare their discriminative powers in predicting poor HRQoL. Compared with other definitions, the WHO definition identified more participants with MetS (41.8 %). Although the AACE definition had higher adjusted odds ratios for reporting poor physical HRQoL (OR: 1.95; CI: 0.84-4.53 and OR: 1.01; CI: 0.55-1.85 in men and women respectively) and mental HRQoL (OR: 0.97; CI: 0.41-2.28 and OR: 1.00; CI: 0.56-1.79 in men and women respectively), none of the three studied definitions were significantly associated with poor physical or mental HRQoL in either gender; nor did ROC curves show any significant difference in the discriminative powers of IR-based definitions in detecting poor HRQoL in either gender. None of the three studied IR-based definitions of MetS could significantly detect poor HRQoL in the physical or mental domains, indicating no significant superior diagnostic value for any of these definitions.

  9. Analysis of surface EMG baseline for detection of hidden muscle activity

    NASA Astrophysics Data System (ADS)

    Zhang, Xu; Zhou, Ping

    2014-02-01

    Objective. This study explored the feasibility of detecting hidden muscle activity in surface electromyogram (EMG) baseline. Approach. Power spectral density (PSD) analysis and multi-scale entropy (MSE) analysis were used. Both analyses were applied to computer simulations of surface EMG baseline with the presence (representing activity data) or absence (representing reference data) of hidden muscle activity, as well as surface electrode array EMG baseline recordings of healthy control and amyotrophic lateral sclerosis (ALS) subjects. Main results. Although the simulated reference data and the activity data yielded no distinguishable difference in the time domain, they demonstrated a significant difference in the frequency and signal complexity domains with the PSD and MSE analyses. For a comparison using pooled data, such a difference was also observed when the PSD and MSE analyses were applied to surface electrode array EMG baseline recordings of healthy control and ALS subjects, which demonstrated no distinguishable difference in the time domain. Compared with the PSD analysis, the MSE analysis appeared to be more sensitive for detecting the difference in surface EMG baselines between the two groups. Significance. The findings implied the presence of a hidden muscle activity in surface EMG baseline recordings from the ALS subjects. To promote the presented analysis as a useful diagnostic or investigatory tool, future studies are necessary to assess the pathophysiological nature or origins of the hidden muscle activity, as well as the baseline difference at the individual subject level.

  10. Analysis of Surface EMG Baseline for Detection of Hidden Muscle Activity

    PubMed Central

    Zhang, Xu; Zhou, Ping

    2014-01-01

    Objective This study explored the feasibility of detecting hidden muscle activity in surface electromyogram (EMG) baseline. Approach Power spectral density (PSD) analysis and multi-scale entropy (MSE) analysis were used respectively. Both analyses were applied to computer simulations of surface EMG baseline with presence (representing activity data) or absence (representing reference data) of hidden muscle activity, as well as surface electrode array EMG baseline recordings of healthy control and amyotrophic lateral sclerosis (ALS) subjects. Main results Although the simulated reference data and the activity data yielded no distinguishable difference in the time domain, they demonstrated a significant difference in the frequency and signal complexity domains with the PSD and MSE analyses. For a comparison using pooled data, such a difference was also observed when the PSD and MSE analyses were applied to surface electrode array EMG baseline recordings of healthy control and ALS subjects, which demonstrated no distinguishable difference in the time domain. Compared with the PSD analysis, the MSE analysis appeared to be more sensitive for detecting the difference in surface EMG baselines between the two groups. Significance The findings implied presence of hidden muscle activity in surface EMG baseline recordings from the ALS subjects. To promote the presented analysis as a useful diagnostic or investigatory tool, future studies are necessary to assess the pathophysiological nature or origins of the hidden muscle activity, as well as the baseline difference at the individual subject level. PMID:24445526

  11. Comparative performance of multiview stereoscopic and mammographic display modalities for breast lesion detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb, Lincoln J.; Samei, Ehsan; Lo, Joseph Y.

    2011-04-15

    Purpose: Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has been shown that stereomammography can overcome these deficiencies by showing that layers of normal tissue lay at different depths. If standard stereomammography (i.e., a single stereoscopic pair consisting of two projection images) can significantly improve lesion detection, how will multiview stereoscopy (MVS), where many projection images are used, compare to mammography?more » The aim of this study was to assess the relative performance of MVS compared to mammography for breast mass detection. Methods: The MVS image sets consisted of the 25 raw projection images acquired over an arc of approximately 45 deg. using a Siemens prototype breast tomosynthesis system. The mammograms were acquired using a commercial Siemens FFDM system. The raw data were taken from both of these systems for 27 cases and realistic simulated mass lesions were added to duplicates of the 27 images at the same local contrast. The images with lesions (27 mammography and 27 MVS) and the images without lesions (27 mammography and 27 MVS) were then postprocessed to provide comparable and representative image appearance across the two modalities. All 108 image sets were shown to five full-time breast imaging radiologists in random order on a state-of-the-art stereoscopic display. The observers were asked to give a confidence rating for each image (0 for lesion definitely not present, 100 for lesion definitely present). The ratings were then compiled and processed using ROC and variance analysis. Results: The mean AUC for the five observers was 0.614{+-}0.055 for mammography and 0.778{+-}0.052 for multiview stereoscopy. The difference of 0.164{+-}0.065 was statistically significant with a p-value of 0.0148. Conclusions: The differences in the AUCs and the p-value suggest that multiview stereoscopy has a statistically significant advantage over mammography in the detection of simulated breast masses. This highlights the dominance of anatomical noise compared to quantum noise for breast mass detection. It also shows that significant lesion detection can be achieved with MVS without any of the artifacts associated with tomosynthesis.« less

  12. Self-detection and clinical breast examination: comparison of the two "classical" physical examination methods for the diagnosis of breast cancer.

    PubMed

    Schwab, Fabienne Dominique; Huang, Dorothy Jane; Schmid, Seraina Margaretha; Schötzau, Andreas; Güth, Uwe

    2015-02-01

    This is the first comprehensive analysis comparing specific aspects of tumor detection between the two "traditional" breast cancer detection methods self-detection (SD) and clinical breast examination (CBE). a) Which method is better in detecting smaller tumors? Both methods showed similar mean tumor diameters (SD: 22.1 mm vs. CBE: 21.9 mm; p = 0.991). b) Different frequency distributions of tumor locations would indicate that certain locations in the breast are more difficult to palpate: comparison of both methods showed comparable results (p = 0.835). c) General differences in tumor sizes with regard to certain locations would be of importance because the patients and/or the physicians could be educated to pay particular attention to certain locations during physical examination, where larger tumors tend to be found: tumors located in the central region were with 25.0 mm significantly larger than those in the peripheral regions of the breast (superior: 21.6 mm, p = 0.001; inferior: 21.6 mm, p = 0.015; lateral: 21.9 mm, p = 0.002; medial (20.9 mm, p = 0.001). Tumor sizes within the four peripheral regions did not differ significantly. d) Patients whose tumors were found by CBE were older than those whose tumors were found by SD (67 years vs. 60 years, p < 0.001). annual CBE should be an integral part of general medical care in older women. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.

    PubMed

    Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon

    2012-01-01

    Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment broths (a total of 441 isolates detected), and correctly excluded all 31 nontarget strains analyzed. For the method comparison, statistical analysis was conducted according to the Mantel-Haenszel Chi-square formula for unpaired test portions, and there was no significant difference in the number of positive samples detected between the Samsung Salmonella Detection Kit and the USDA/FSIS-MLG and FDA/BAM reference methods for all 10 food matrixes.

  14. Evaluation of clinical image processing algorithms used in digital mammography.

    PubMed

    Zanca, Federica; Jacobs, Jurgen; Van Ongeval, Chantal; Claus, Filip; Celis, Valerie; Geniets, Catherine; Provost, Veerle; Pauwels, Herman; Marchal, Guy; Bosmans, Hilde

    2009-03-01

    Screening is the only proven approach to reduce the mortality of breast cancer, but significant numbers of breast cancers remain undetected even when all quality assurance guidelines are implemented. With the increasing adoption of digital mammography systems, image processing may be a key factor in the imaging chain. Although to our knowledge statistically significant effects of manufacturer-recommended image processings have not been previously demonstrated, the subjective experience of our radiologists, that the apparent image quality can vary considerably between different algorithms, motivated this study. This article addresses the impact of five such algorithms on the detection of clusters of microcalcifications. A database of unprocessed (raw) images of 200 normal digital mammograms, acquired with the Siemens Novation DR, was collected retrospectively. Realistic simulated microcalcification clusters were inserted in half of the unprocessed images. All unprocessed images were subsequently processed with five manufacturer-recommended image processing algorithms (Agfa Musica 1, IMS Raffaello Mammo 1.2, Sectra Mamea AB Sigmoid, Siemens OPVIEW v2, and Siemens OPVIEW v1). Four breast imaging radiologists were asked to locate and score the clusters in each image on a five point rating scale. The free-response data were analyzed by the jackknife free-response receiver operating characteristic (JAFROC) method and, for comparison, also with the receiver operating characteristic (ROC) method. JAFROC analysis revealed highly significant differences between the image processings (F = 8.51, p < 0.0001), suggesting that image processing strongly impacts the detectability of clusters. Siemens OPVIEW2 and Siemens OPVIEW1 yielded the highest and lowest performances, respectively. ROC analysis of the data also revealed significant differences between the processing but at lower significance (F = 3.47, p = 0.0305) than JAFROC. Both statistical analysis methods revealed that the same six pairs of modalities were significantly different, but the JAFROC confidence intervals were about 32% smaller than ROC confidence intervals. This study shows that image processing has a significant impact on the detection of microcalcifications in digital mammograms. Objective measurements, such as described here, should be used by the manufacturers to select the optimal image processing algorithm.

  15. Local subcutaneous and muscle pain impairs detection of passive movements at the human thumb

    PubMed Central

    Weerakkody, N S; Blouin, J S; Taylor, J L; Gandevia, S C

    2008-01-01

    Activity in both muscle spindle endings and cutaneous stretch receptors contributes to the sensation of joint movement. The present experiments assessed whether muscle pain and subcutaneous pain distort proprioception in humans. The ability to detect the direction of passive movements at the interphalangeal joint of the thumb was measured when pain was induced experimentally in four sites: the flexor pollicis longus (FPL), the subcutaneous tissue overlying this muscle, the flexor carpi radialis (FCR) muscle and the subcutaneous tissue distal to the metacarpophalangeal joint of thumb. Tests were conducted when pain was at a similar subjective intensity. There was no significant difference in the ability to detect flexion or extension under any painful or non-painful condition. The detection of movement was significantly impaired when pain was induced in the FPL muscle, but pain in the FCR, a nearby muscle that does not act on the thumb, had no effect. Subcutaneous pain also significantly impaired movement detection when initiated in skin overlying the thumb, but not in skin overlying the FPL muscle in the forearm. These findings suggest that while both muscle and skin pain can disturb the detection of the direction of movement, the impairment is site-specific and involves regions and tissues that have a proprioceptive role at the joint. Also, pain induced in FPL did not significantly increase the perceived size of the thumb. Proprioceptive mechanisms signalling perceived body size are less disturbed by a relevant muscle nociceptive input than those subserving movement detection. The results highlight the complex relationship between nociceptive inputs and their influence on proprioception and motor control. PMID:18467366

  16. Taste sensitivity, nutritional status and metabolic syndrome: Implication in weight loss dietary interventions

    PubMed Central

    Bertoli, Simona; Laureati, Monica; Battezzati, Alberto; Bergamaschi, Valentina; Cereda, Emanuele; Spadafranca, Angela; Vignati, Laila; Pagliarini, Ella

    2014-01-01

    AIM: We investigated the relationship between taste sensitivity, nutritional status and metabolic syndrome and possible implications on weight loss dietary program. METHODS: Sensitivity for bitter, sweet, salty and sour tastes was assessed by the three-Alternative-Forced-Choice method in 41 overweight (OW), 52 obese (OB) patients and 56 normal-weight matched controls. OW and OB were assessed also for body composition (by impedence), resting energy expenditure (by indirect calorimetry) and presence of metabolic syndrome (MetS) and were prescribed a weight loss diet. Compliance to the weight loss dietary program was defined as adherence to control visits and weight loss ≥ 5% in 3 mo. RESULTS: Sex and age-adjusted multiple regression models revealed a significant association between body mass index (BMI) and both sour taste (P < 0.05) and global taste acuity score (GTAS) (P < 0.05), with lower sensitivity with increasing BMI. This trend in sensitivity for sour taste was also confirmed by the model refitted on the OW/OB group while the association with GTAS was marginally significant (P = 0.06). MetS+ subjects presented higher thresholds for salty taste when compared to MetS- patients while no significant difference was detected for the other tastes and GTAS. As assessed by multiple regression model, the association between salty taste and MetS appeared to be independent of sex, age and BMI. Patients continuing the program (n = 37) did not show any difference in baseline taste sensitivity when compared to drop-outs (n = 29). Similarly, no significant difference was detected between patients reporting and not reporting a weight loss ≥ 5% of the initial body weight. No significant difference in taste sensitivity was detected even after dividing patients on the basis of nutritional (OW and OB) or metabolic status (MetS+ and MetS-). CONCLUSION: There is no cause-effect relationship between overweight and metabolic derangements. Taste thresholds assessment is not useful in predicting the outcome of a diet-induced weight loss program. PMID:25317249

  17. Cross-modality PET/CT and contrast-enhanced CT imaging for pancreatic cancer

    PubMed Central

    Zhang, Jian; Zuo, Chang-Jing; Jia, Ning-Yang; Wang, Jian-Hua; Hu, Sheng-Ping; Yu, Zhong-Fei; Zheng, Yuan; Zhang, An-Yu; Feng, Xiao-Yuan

    2015-01-01

    AIM: To explore the diagnostic value of the cross-modality fusion images provided by positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT (CECT) for pancreatic cancer (PC). METHODS: Data from 70 patients with pancreatic lesions who underwent CECT and PET/CT examinations at our hospital from August 2010 to October 2012 were analyzed. PET/CECT for the cross-modality image fusion was obtained using TureD software. The diagnostic efficiencies of PET/CT, CECT and PET/CECT were calculated and compared with each other using a χ2 test. P < 0.05 was considered to indicate statistical significance. RESULTS: Of the total 70 patients, 50 had PC and 20 had benign lesions. The differences in the sensitivity, negative predictive value (NPV), and accuracy between CECT and PET/CECT in detecting PC were statistically significant (P < 0.05 for each). In 15 of the 31 patients with PC who underwent a surgical operation, peripancreatic vessel invasion was verified. The differences in the sensitivity, positive predictive value, NPV, and accuracy of CECT vs PET/CT and PET/CECT vs PET/CT in diagnosing peripancreatic vessel invasion were statistically significant (P < 0.05 for each). In 19 of the 31 patients with PC who underwent a surgical operation, regional lymph node metastasis was verified by postsurgical histology. There was no statistically significant difference among the three methods in detecting regional lymph node metastasis (P > 0.05 for each). In 17 of the 50 patients with PC confirmed by histology or clinical follow-up, distant metastasis was confirmed. The differences in the sensitivity and NPV between CECT and PET/CECT in detecting distant metastasis were statistically significant (P < 0.05 for each). CONCLUSION: Cross-modality image fusion of PET/CT and CECT is a convenient and effective method that can be used to diagnose and stage PC, compensating for the defects of PET/CT and CECT when they are conducted individually. PMID:25780297

  18. Presence of very high prevalence and intensity of infection with Fasciola hepatica among Aymara children from the Northern Bolivian Altiplano.

    PubMed

    Esteban, J G; Flores, A; Aguirre, C; Strauss, W; Angles, R; Mas-Coma, S

    1997-06-24

    Coprological studies of school children from four communities in the Northern Bolivian Altiplano were carried out in order to estimate the prevalences and intensities of Fasciola hepatica infection. Single stool specimens were collected at random from 558 school children (308 boys and 250 girls) aged 5-19 years old. Nineteen different parasite species (13 protozoan and six helminths) were detected. Of the children examined, 98.7% (96.5-100%) presented infection with at least one parasite species. The mean prevalence of 27.6% by Fasciola hepatica (range, 5.9-38.2%) was the highest not only with respect to the helminth species found in the Northern Bolivian Altiplano but also among the fasciolosis prevalences reported in children in other parts of the world to date. Prevalences were significantly different among the communities surveyed and was significantly higher in the 9-12 years age group. There were, however, no significant differences between sexes. Among the 154 children presenting F. hepatica eggs in stools, intensities ranged from 24-5064 eggs per gram of faeces (epg), with arithmetic and geometric means of 474 and 201 epg, respectively. Significant differences in mean egg output were detected between communities, sexes and age groups. Individual fasciolosis infections coexisting with other pathogenic parasite species (Entamoeba histolytica and/or E. dispar, Giardia intestinalis, Balantidium coli, Dientamoeba fragilis, Cryptosporidium sp., Hymenolepis nana, Taenia spp., Trichuris trichiura, Ascaris lumbricoides and Enterobius vermicularis) were detected. A significant positive association with F. hepatica was only found in the case of G. intestinalis. This coprological study not only verifies the existence of high prevalences of F. hepatica among humans in the Northern Bolivian Altiplano, but also demonstrates the need to expand the Southern boundaries of this high endemic zone to include the Southeastern region of Lake Titicaca.

  19. Detection frequency of human herpesviruses-6A, -6B, and -7 genomic sequences in central nervous system DNA samples from post-mortem individuals with unspecified encephalopathy.

    PubMed

    Chapenko, Svetlana; Roga, Silvija; Skuja, Sandra; Rasa, Santa; Cistjakovs, Maksims; Svirskis, Simons; Zaserska, Zane; Groma, Valerija; Murovska, Modra

    2016-08-01

    In this autopsy-based study, human herpesvirus-6 (HHV-6) and -7 (HHV-7) genomic sequence frequency, HHV-6 variants, HHV-6 load and the expression of HHV-6 antigens in brain samples from the individuals, with and without unspecified encephalopathy (controls), using nested and real-time polymerase chain reactions, restriction endonuclease, and immunohistochemical analysis were examined. GraphPad Prism 6.0 Mann-Whitney nonparametric and chi-square test and Fisher's exact test were used for statistical analysis. The encephalopathy diagnoses were shown by magnetic resonance imaging made during their lifetime and macro- and microscopically studied autopsy tissue materials. Widespread HHV-6 and/or HHV-7 positivity was detected in the brain tissue of various individuals with encephalopathy, as well as in controls (51/57, 89.4 % and 35/51, 68.6 %, respectively; p = 0.009). Significantly higher detection frequency of single HHV-6 and concurrent HHV-6 + HHV-7 DNA was found in pia mater meninges, frontal lobe, temporal lobe, and olfactory tract DNAs in individuals with encephalopathy compared to the control group. HHV-6 load and higher frequency of the viral load >10 copies/10(6) cells significantly differed in samples from individuals with and without encephalopathy. The expression of HHV-6 antigens was revealed in different neural cell types with strong predominance in the encephalopathy group. In all HHV-6-positive autopsy samples of individuals with and without encephalopathy, HHV-6B was revealed. Significantly higher detection frequency of beta-herpesvirus DNA, more often detected HHV-6 load >10 copies/10(6) cells, as well as the expression of HHV-6 antigens in different brain tissue samples from individuals with encephalopathy in comparison with control group indicate on potential involvement of these viruses in encephalopathy development.

  20. Rear-end vision-based collision detection system for motorcyclists

    NASA Astrophysics Data System (ADS)

    Muzammel, Muhammad; Yusoff, Mohd Zuki; Meriaudeau, Fabrice

    2017-05-01

    In many countries, the motorcyclist fatality rate is much higher than that of other vehicle drivers. Among many other factors, motorcycle rear-end collisions are also contributing to these biker fatalities. To increase the safety of motorcyclists and minimize their road fatalities, this paper introduces a vision-based rear-end collision detection system. The binary road detection scheme contributes significantly to reduce the negative false detections and helps to achieve reliable results even though shadows and different lane markers are present on the road. The methodology is based on Harris corner detection and Hough transform. To validate this methodology, two types of dataset are used: (1) self-recorded datasets (obtained by placing a camera at the rear end of a motorcycle) and (2) online datasets (recorded by placing a camera at the front of a car). This method achieved 95.1% accuracy for the self-recorded dataset and gives reliable results for the rear-end vehicle detections under different road scenarios. This technique also performs better for the online car datasets. The proposed technique's high detection accuracy using a monocular vision camera coupled with its low computational complexity makes it a suitable candidate for a motorbike rear-end collision detection system.

  1. Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.

    PubMed

    Sanjay, Sharma T; Fu, Guanglei; Dou, Maowei; Xu, Feng; Liu, Rutao; Qi, Hao; Li, XiuJun

    2015-11-07

    Early and timely detection of disease biomarkers can prevent the spread of infectious diseases, and drastically decrease the death rate of people suffering from different diseases such as cancer and infectious diseases. Because conventional diagnostic methods have limited application in low-resource settings due to the use of bulky and expensive instrumentation, simple and low-cost point-of-care diagnostic devices for timely and early biomarker diagnosis is the need of the hour, especially in rural areas and developing nations. The microfluidics technology possesses remarkable features for simple, low-cost, and rapid disease diagnosis. There have been significant advances in the development of microfluidic platforms for biomarker detection of diseases. This article reviews recent advances in biomarker detection using cost-effective microfluidic devices for disease diagnosis, with the emphasis on infectious disease and cancer diagnosis in low-resource settings. This review first introduces different microfluidic platforms (e.g. polymer and paper-based microfluidics) used for disease diagnosis, with a brief description of their common fabrication techniques. Then, it highlights various detection strategies for disease biomarker detection using microfluidic platforms, including colorimetric, fluorescence, chemiluminescence, electrochemiluminescence (ECL), and electrochemical detection. Finally, it discusses the current limitations of microfluidic devices for disease biomarker detection and future prospects.

  2. An Enhanced Smoke Detection Using MODIS Measurements

    NASA Astrophysics Data System (ADS)

    Xie, Y.; Qu, J.; Xiong, X.; Hao, X.; Wang, W.; Wang, L.

    2005-12-01

    Smoke emitted from wildfire fires or prescribed fires is one of the major pollutions that pose a risk to human health and affect the air quality significantly. The remote sensing technique has been demonstrated as an efficient approach for detecting and tracing smoke plume. As a mixture pollutant, smoke does not have stable spectral signature because of diversified component mixing levels in different situation, but it has some particular characteristics different from others such as cloud, soil, water and so on. In earlier studies, we have already developed a multi-threshold algorithm to detect smoke in the eastern United States by combining both MODIS reflective solar bands and thermal emissive bands measurements. In order to apply out approach to global scale, we have enhanced the smoke detection algorithm by taking the land surface type into account. Smoke pixels will be output as well as the confidence in the quality of product in final result. In addition, smoke detection is also helpful to fire detection. With current fire detection algorithm, some small and cool fires can not be detected. However, understanding the features and spread direction of smoke can provide us a potential way to identify these fires.

  3. Accuracy of digital radiography and cone beam computed tomography on periapical radiolucency detection in endodontically treated teeth.

    PubMed

    Venskutonis, Tadas; Daugela, Povilas; Strazdas, Marijus; Juodzbalys, Gintaras

    2014-04-01

    The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images) from 60 patients, achieved from September 2008 to July 2013, were retrieved from databases of the Department of Oral Diseases, Lithuanian University of Health Sciences. Twenty patients met inclusion criteria and were selected for further evaluation. In 20 patients (42.4 [SD 12.1] years, 65% men and 35% women) a total of 35 endodontically treated teeth (1.75 [SD 0.91]; 27 in maxilla and 8 in mandible) were evaluated. Overall, it was observed a statistical significant difference between the number of periapical lesions observed in the CBCT (n = 42) and radiographic (n = 24) examinations (P < 0.05). In molar teeth, CBCT identify a significantly higher amount of periapical lesions than with the radiographic method (P < 0.05). There were significant differences between CBCT and PR in the mean number of lesions identified per tooth (1.2 vs 0.66, P = 0.03), number of teeth with lesions (0.71 vs 0.46, P = 0.03) and number of lesions identified per canal (0.57 vs 0.33, P = 0.005). Considering CBCT as "gold standard" in lesion detection with the sensitivity, specificity and accuracy considering as score 1, then the same parameters of PR were 0.57, 1 and 0.76 respectively. Within the limitations of the present study, it can be concluded that cone beam computed tomography scans were more accurate compared to digital periapical radiographs for detecting periapical radiolucencies in endodontically treated teeth. The difference was more pronounced in molar teeth.

  4. Validation of the ANSR Salmonella method for detection of Salmonella spp. in selected foods and environmental samples.

    PubMed

    Mozola, Mark; Norton, Paul; Alles, Susan; Gray, R Lucas; Tolan, Jerry; Caballero, Oscar; Pinkava, Lisa; Hosking, Edan; Luplow, Karen; Rice, Jennifer

    2013-01-01

    ANSR Salmonella is a new molecular diagnostic assay for detection of Salmonella spp. in foods and environmental samples. The test is based on the nicking enzyme amplification reaction (NEAR) isothermal nucleic acid amplification technology. The assay platform features simple instrumentation, minimal labor, and, following a single-step 10-24 h enrichment (depending on sample type), an extremely short assay time of 30 min, including sample preparation. Detection is real-time using fluorescent molecular beacon probes. Inclusivity testing was performed using a panel of 113 strains of S. enterica and S. bongori, representing 109 serovars and all genetic subgroups. With the single exception of the rare serovar S. Weslaco, all serovars and genetic subgroups were detected. Exclusivity testing of 38 non-salmonellae, mostly Enterobacteriaceae, yielded no evidence of cross-reactivity. In comparative testing of chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, and oat cereal, there were no statistically significant differences in the number of positive results obtained with the ANSR and the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods. In testing of swab or sponge samples from five different environmental surfaces, four trials showed no statistically significant differences in the number of positive results by the ANSR and the U.S. Food and Drug Administration/ Bacteriological Analytical Manual reference methods; in the trial with stainless steel surface, there were significantly more positive results by the ANSR method. Ruggedness experiments showed a high degree of assay robustness when deviations in reagent volumes and incubation times were introduced.

  5. Application of Abbreviated Protocol of Magnetic Resonance Imaging for Breast Cancer Screening in Dense Breast Tissue.

    PubMed

    Chen, Shuang-Qing; Huang, Min; Shen, Yu-Ying; Liu, Chen-Lu; Xu, Chuan-Xiao

    2017-03-01

    The study aimed to evaluate the usefulness of an abbreviated protocol (AP) of magnetic resonance imaging (MRI) in comparison to a full diagnostic protocol (FDP) of MRI in the breast cancer screening with dense breast tissue. There are 478 female participants with dense breast tissue and negative mammography results, who were imaged with MRI using AP and FDP. The AP and FDP images were analyzed separately, and the sensitivity and specificity of breast cancer detection were calculated. The chi-square test and receiver operating characteristics curves were used to assess the breast cancer diagnostic capabilities of the two protocols. Sixteen cases of breast cancer from 478 patients with dense breasts were detected using the FDP method, with pathologic confirmation of nine cases of ductal carcinoma in situ, six cases of invasive ductal carcinoma, and one case of mucinous carcinoma. Fifteen cases of breast cancer were successfully screened using the AP method. The sensitivity showed no obvious significant difference between AP and FDP (χ 2  = 0.592, P = 0.623), but the specificity showed a statistically significant difference (χ 2  = 4.619, P = 0.036). The receiver operating characteristics curves showed high efficacy of both methods in the detection of breast cancer in dense breast tissue (the areas under the curve were 0.931 ± 0.025 and 0.947 ± 0.024, respectively), and the ability to diagnose breast cancer was not statistically significantly different between the two methods. The AP of MRI may improve the detection rate of breast cancer in dense breast tissue, and it may be useful in efficient breast cancer screening. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Detection of a gravitropism phenotype in glutamate receptor-like 3.3 mutants of Arabidopsis thaliana using machine vision and computation.

    PubMed

    Miller, Nathan D; Durham Brooks, Tessa L; Assadi, Amir H; Spalding, Edgar P

    2010-10-01

    Gene disruption frequently produces no phenotype in the model plant Arabidopsis thaliana, complicating studies of gene function. Functional redundancy between gene family members is one common explanation but inadequate detection methods could also be responsible. Here, newly developed methods for automated capture and processing of time series of images, followed by computational analysis employing modified linear discriminant analysis (LDA) and wavelet-based differentiation, were employed in a study of mutants lacking the Glutamate Receptor-Like 3.3 gene. Root gravitropism was selected as the process to study with high spatiotemporal resolution because the ligand-gated Ca(2+)-permeable channel encoded by GLR3.3 may contribute to the ion fluxes associated with gravity signal transduction in roots. Time series of root tip angles were collected from wild type and two different glr3.3 mutants across a grid of seed-size and seedling-age conditions previously found to be important to gravitropism. Statistical tests of average responses detected no significant difference between populations, but LDA separated both mutant alleles from the wild type. After projecting the data onto LDA solution vectors, glr3.3 mutants displayed greater population variance than the wild type in all four conditions. In three conditions the projection means also differed significantly between mutant and wild type. Wavelet analysis of the raw response curves showed that the LDA-detected phenotypes related to an early deceleration and subsequent slower-bending phase in glr3.3 mutants. These statistically significant, heritable, computation-based phenotypes generated insight into functions of GLR3.3 in gravitropism. The methods could be generally applicable to the study of phenotypes and therefore gene function.

  7. Detection of a Gravitropism Phenotype in glutamate receptor-like 3.3 Mutants of Arabidopsis thaliana Using Machine Vision and Computation

    PubMed Central

    Miller, Nathan D.; Durham Brooks, Tessa L.; Assadi, Amir H.; Spalding, Edgar P.

    2010-01-01

    Gene disruption frequently produces no phenotype in the model plant Arabidopsis thaliana, complicating studies of gene function. Functional redundancy between gene family members is one common explanation but inadequate detection methods could also be responsible. Here, newly developed methods for automated capture and processing of time series of images, followed by computational analysis employing modified linear discriminant analysis (LDA) and wavelet-based differentiation, were employed in a study of mutants lacking the Glutamate Receptor-Like 3.3 gene. Root gravitropism was selected as the process to study with high spatiotemporal resolution because the ligand-gated Ca2+-permeable channel encoded by GLR3.3 may contribute to the ion fluxes associated with gravity signal transduction in roots. Time series of root tip angles were collected from wild type and two different glr3.3 mutants across a grid of seed-size and seedling-age conditions previously found to be important to gravitropism. Statistical tests of average responses detected no significant difference between populations, but LDA separated both mutant alleles from the wild type. After projecting the data onto LDA solution vectors, glr3.3 mutants displayed greater population variance than the wild type in all four conditions. In three conditions the projection means also differed significantly between mutant and wild type. Wavelet analysis of the raw response curves showed that the LDA-detected phenotypes related to an early deceleration and subsequent slower-bending phase in glr3.3 mutants. These statistically significant, heritable, computation-based phenotypes generated insight into functions of GLR3.3 in gravitropism. The methods could be generally applicable to the study of phenotypes and therefore gene function. PMID:20647506

  8. Quantifying the physical demands of collision sports: does microsensor technology measure what it claims to measure?

    PubMed

    Gabbett, Tim J

    2013-08-01

    The physical demands of rugby league, rugby union, and American football are significantly increased through the large number of collisions players are required to perform during match play. Because of the labor-intensive nature of coding collisions from video recordings, manufacturers of wearable microsensor (e.g., global positioning system [GPS]) units have refined the technology to automatically detect collisions, with several sport scientists attempting to use these microsensors to quantify the physical demands of collision sports. However, a question remains over the validity of these microtechnology units to quantify the contact demands of collision sports. Indeed, recent evidence has shown significant differences in the number of "impacts" recorded by microtechnology units (GPSports) and the actual number of collisions coded from video. However, a separate study investigated the validity of a different microtechnology unit (minimaxX; Catapult Sports) that included GPS and triaxial accelerometers, and also a gyroscope and magnetometer, to quantify collisions. Collisions detected by the minimaxX unit were compared with video-based coding of the actual events. No significant differences were detected in the number of mild, moderate, and heavy collisions detected via the minimaxX units and those coded from video recordings of the actual event. Furthermore, a strong correlation (r = 0.96, p < 0.01) was observed between collisions recorded via the minimaxX units and those coded from video recordings of the event. These findings demonstrate that only one commercially available and wearable microtechnology unit (minimaxX) can be considered capable of offering a valid method of quantifying the contact loads that typically occur in collision sports. Until such validation research is completed, sport scientists should be circumspect of the ability of other units to perform similar functions.

  9. The value of different insulin resistance indices in assessment of non-alcoholic fatty liver disease in overweight/obese children.

    PubMed

    El-Karaksy, Hanaa M; El-Raziky, Mona S; Fouad, Hanan M; Anwar, Ghada M; El-Mougy, Fatma M; El-Koofy, Nehal M; El-Hennawy, Ahmad M

    2015-01-01

    The aim of the present study was to determine the association between insulin resistance (IR) and both non-alcoholic fatty liver disease (NAFLD) and metabolic syndrome (MetS) in a group of Egyptian overweight/obese children and adolescents and to evaluate different IR indices in detection of NAFLD. The study included 76 overweight/obese children aged 2-15 years; 52.6% were males. Laboratory analysis included fasting blood glucose, serum insulin, lipid profile, liver biochemical profile, and liver ultrasound. IR was calculated using the following indices; the homeostasis model assessment method (HOMA-IR), the quantitative insulin-sensitivity check index (QUICKI) and hepatic insulin sensitivity. The National Cholesterol Education Program Adult Treatment Panel III criteria were used to estimate prevalence of MetS. Liver biopsy was done when medically indicated and accepted by parents. IR was detected in 43.4% and 34.2% by using QUICKI and HOMA, respectively. MetS was detected in 36.8% and NAFLD was detected in 45.5% among those performing liver biopsy. Cases with NAFLD had more frequent IR than children with normal histology. QUICKI showed significant difference between normal subjects and both steatosis and non-alcoholic steatohepatitis; while HOMA-IR was sensitive in cases with NASH only. MetS was present in 100% of patients with NASH and in 75% of those with steatosis and they were all obese. Patients with NASH had significantly higher ALT than those with normal histology. IR was significantly associated with NAFLD. QUICKI is considered more sensitive than HOMA-IR in differentiating simple steatosis from normal liver histology. Copyright © 2013 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  10. Diagnostic performance of magnetic resonance imaging and 3D endoanal ultrasound in detection, staging and assessment post treatment, in anal cancer.

    PubMed

    Reginelli, Alfonso; Granata, Vincenza; Fusco, Roberta; Granata, Francesco; Rega, Daniela; Roberto, Luca; Pellino, Gianluca; Rotondo, Antonio; Selvaggi, Francesco; Izzo, Francesco; Petrillo, Antonella; Grassi, Roberto

    2017-04-04

    We compared Magnetic Resonance Imaging (MRI) and 3D Endoanal Ultrasound (EAUS) imaging performance to confirm anal carcinoma and to monitor treatment response.58 patients with anal cancer were retrospectively enrolled. All patients underwent clinical examination, anoscopic examination; EAUS and contrast-enhanced MRI study before and after treatment. Four radiologists evaluated the presence of lesions, using a 4-point confidence scale, features of the lesion and nodes on EAUS images, T1-weighted (T1-W), T2-weighted (T2-W) and diffusion-weighted images (DWI) signal intensity (SI), the apparent diffusion coefficient (ADC) map for nodes and lesion, as well as enhancement pattern during dynamic MRI were assessed.All lesions were detected by EAUS while MRI detected 93.1% of anal cancer. MRI showed a good correlation with EAUS, anoscopy and clinical examination. The residual tissue not showed significant difference in EAUS assessment and T2-W SI in pre and post treatment. We found significant difference in dynamic study, in SI of DWI, in ADC map and values among responder's patients in pre and post treatment. The neoplastic nodes were hypoecoic on EAUS, with hyperintense signal on T2-W sequences and hypointense signal on T1-W. The neoplastic nodes showed SI on DWI sequences and ADC value similar to anal cancer. We found significant difference in nodes status in pre and post therapy on DWI data.3D EAUS and MRI are accurate techniques in anal cancer staging, although EAUS is more accurate than MRI for T1 stage. MRI allows correct detection of neoplastic nodes and can properly stratify patients into responders or non responders.

  11. Detection of thoracic vascular structures by electrical impedance tomography: a systematic assessment of prominence peak analysis of impedance changes.

    PubMed

    Wodack, K H; Buehler, S; Nishimoto, S A; Graessler, M F; Behem, C R; Waldmann, A D; Mueller, B; Böhm, S H; Kaniusas, E; Thürk, F; Maerz, A; Trepte, C J C; Reuter, D A

    2018-02-28

    Electrical impedance tomography (EIT) is a non-invasive and radiation-free bedside monitoring technology, primarily used to monitor lung function. First experimental data shows that the descending aorta can be detected at different thoracic heights and might allow the assessment of central hemodynamics, i.e. stroke volume and pulse transit time. First, the feasibility of localizing small non-conductive objects within a saline phantom model was evaluated. Second, this result was utilized for the detection of the aorta by EIT in ten anesthetized pigs with comparison to thoracic computer tomography (CT). Two EIT belts were placed at different thoracic positions and a bolus of hypertonic saline (10 ml, 20%) was administered into the ascending aorta while EIT data were recorded. EIT images were reconstructed using the GREIT model, based on the individual's thoracic contours. The resulting EIT images were analyzed pixel by pixel to identify the aortic pixel, in which the bolus caused the highest transient impedance peak in time. In the phantom, small objects could be located at each position with a maximal deviation of 0.71 cm. In vivo, no significant differences between the aorta position measured by EIT and the anatomical aorta location were obtained for both measurement planes if the search was restricted to the dorsal thoracic region of interest (ROIs). It is possible to detect the descending aorta at different thoracic levels by EIT using an intra-aortic bolus of hypertonic saline. No significant differences in the position of the descending aorta on EIT images compared to CT images were obtained for both EIT belts.

  12. Damage Proxy Map from InSAR Coherence Applied to February 2011 M6.3 Christchurch Earthquake, 2011 M9.0 Tohoku-oki Earthquake, and 2011 Kirishima Volcano Eruption

    NASA Astrophysics Data System (ADS)

    Yun, S.; Agram, P. S.; Fielding, E. J.; Simons, M.; Webb, F.; Tanaka, A.; Lundgren, P.; Owen, S. E.; Rosen, P. A.; Hensley, S.

    2011-12-01

    Under ARIA (Advanced Rapid Imaging and Analysis) project at JPL and Caltech, we developed a prototype algorithm to detect surface property change caused by natural or man-made damage using InSAR coherence change. The algorithm was tested on building demolition and construction sites in downtown Pasadena, California. The developed algorithm performed significantly better, producing 150 % higher signal-to-noise ratio, than a standard coherence change detection method. We applied the algorithm to February 2011 M6.3 Christchurch earthquake in New Zealand, 2011 M9.0 Tohoku-oki earthquake in Japan, and 2011 Kirishima volcano eruption in Kyushu, Japan, using ALOS PALSAR data. In Christchurch area we detected three different types of damage: liquefaction, building collapse, and landslide. The detected liquefaction damage is extensive in the eastern suburbs of Christchurch, showing Bexley as one of the most significantly affected areas as was reported in the media. Some places show sharp boundaries of liquefaction damage, indicating different type of ground materials that might have been formed by the meandering Avon River in the past. Well reported damaged buildings such as Christchurch Cathedral, Canterbury TV building, Pyne Gould building, and Cathedral of the Blessed Sacrament were detected by the algorithm. A landslide in Redcliffs was also clearly detected. These detected damage sites were confirmed with Google earth images provided by GeoEye. Larger-scale damage pattern also agrees well with the ground truth damage assessment map indicated with polygonal zones of 3 different damage levels, compiled by the government of New Zealand. The damage proxy map of Sendai area in Japan shows man-made structure damage due to the tsunami caused by the M9.0 Tohoku-oki earthquake. Long temporal baseline (~2.7 years) and volume scattering caused significant decorrelation in the farmlands and bush forest along the coastline. The 2011 Kirishima volcano eruption caused a lot of ash fall deposit in the southeast from the volcano. The detected ash fall damage area exactly matches the in-situ measurements implemented through fieldwork by Geological Survey of Japan. With 99-percentile threshold for damage detection, the periphery of the detected damage area aligns with a contour line of 100 kg/m2 ash deposit, equivalent to 10 cm of depth assuming a density of 1000 kg/m3 for the ash layer. With growing number of InSAR missions, rapidly produced accurate damage assessment maps will help save people, assisting effective prioritization of rescue operations at early stage of response, and significantly improve timely situational awareness for emergency management and national / international assessment and response for recovery planning. Results of this study will also inform the design of future InSAR missions including the proposed DESDynI.

  13. [Clinical validation of multiple biomarkers suspension array technology for ovarian cancer].

    PubMed

    Zhao, B B; Yang, Z J; Wang, Q; Pan, Z M; Zhang, W; Li, L

    2017-01-25

    Objective: To investigates the diagnostic value of combined detection serum CCL18, CXCL1 antigen, C1D, TM4SF1, FXR1, TIZ IgG autoantibody by suspension array for ovarian cancer. Methods: Suspension array was used to detect CCL18, CXCL1 antigen, C1D, TM4SF1, FXR1, TIZ IgG autoantibody in 120 cases of healthy women, 204 cases of patients with benign pelvic tumors, 119 cases of pelvic malignant tumor patients, and 40 cases with breast cancer, lung cancer oroliver cancer, respectively. Constructed diagnosis model of combined detection six biomarkers for diagnosis of ovarian malignant tumor. Constructed diagnosis model of combined detection autoantibodies to diagnose epithelial ovarian cancer. Analysed the value of detecting six biomarkers for diagnosis of ovarian malignant tumor and detecting autoantibodies for diagnosis of epithelial ovarian cancer. Analysed diagnostic value of detecting six biomarkers to diagnose stage Ⅰ and Ⅱepithelial ovarian cancer. Compared diagnostic value of detecting six biomarkers in diagnosis of tissue types and pathologic grading with that of CA(125). Results: Model of combined detecting six biomarkers to diagnose ovarian malignant tumor was logit ( P ) =-11.151+0.008×C1D+0.011×TM4SF1+0.011×TIZ-0.008×FXR1+0.021×CCL18+0.200×CXCL1. Model of combined detection autoantibodies to diagnose epithelial ovarian cancer was logit ( P ) =-5.137+0.013×C1D+0.014×TM4SF1+0.060×TIZ-0.060×FXR1. Sensitivity and specificity of detecting six biomarker to diagnose ovarian malignant tumor was 90.6% and 98.7%. Sensitivity and specificity of detecting autoantibodies to diagnose epithelial ovarian cancer was 75.8% and 96.7%. Combined detection for six biomarkers to diagnose serous and mucinous ovarian cancer was statistically no better than those of CA(125) ( P =0.196 and P =0.602, respectively); there was significantly difference in diagnosis of ovarian cancer ( P =0.023), and there was no significantly difference in diagnosis of different pathological grading ( P =0.089 and P =0.169, respectively). Conclusions: Constructing diagnosis model of combined detection six biomarker to diagnose ovarian malignant tumor and constructed diagnosis model of combined detectionautoantibodies to diagnose epithelial ovarian cancer. Combined detection six biomarkers to diagnose serous and mucinous ovarian tumors is better than that of CA(125).

  14. Evaluation of different mathematical models and different b-value ranges of diffusion-weighted imaging in peripheral zone prostate cancer detection using b-value up to 4500 s/mm2

    PubMed Central

    Feng, Zhaoyan; Min, Xiangde; Margolis, Daniel J. A.; Duan, Caohui; Chen, Yuping; Sah, Vivek Kumar; Chaudhary, Nabin; Li, Basen; Ke, Zan; Zhang, Peipei; Wang, Liang

    2017-01-01

    Objectives To evaluate the diagnostic performance of different mathematical models and different b-value ranges of diffusion-weighted imaging (DWI) in peripheral zone prostate cancer (PZ PCa) detection. Methods Fifty-six patients with histologically proven PZ PCa who underwent DWI-magnetic resonance imaging (MRI) using 21 b-values (0–4500 s/mm2) were included. The mean signal intensities of the regions of interest (ROIs) placed in benign PZs and cancerous tissues on DWI images were fitted using mono-exponential, bi-exponential, stretched-exponential, and kurtosis models. The b-values were divided into four ranges: 0–1000, 0–2000, 0–3200, and 0–4500 s/mm2, grouped as A, B, C, and D, respectively. ADC, , D*, f, DDC, α, Dapp, and Kapp were estimated for each group. The adjusted coefficient of determination (R2) was calculated to measure goodness-of-fit. Receiver operating characteristic curve analysis was performed to evaluate the diagnostic performance of the parameters. Results All parameters except D* showed significant differences between cancerous tissues and benign PZs in each group. The area under the curve values (AUCs) of ADC were comparable in groups C and D (p = 0.980) and were significantly higher than those in groups A and B (p< 0.05 for all). The AUCs of ADC and Kapp in groups B and C were similar (p = 0.07 and p = 0.954), and were significantly higher than the other parameters (p< 0.001 for all). The AUCs of ADC in group D was slightly higher than Kapp (p = 0.002), and both were significantly higher than the other parameters (p< 0.001 for all). Conclusions ADC derived from conventional mono-exponential high b-value (3200 s/mm2) models is an optimal parameter for PZ PCa detection. PMID:28199367

  15. Kisspeptin levels in idiopathic hypogonadotropic hypogonadism diagnosed male patients and its relation with glucose-insulin dynamic.

    PubMed

    Öztin, Hasan; Çağıltay, Eylem; Çağlayan, Sinan; Kaplan, Mustafa; Akpak, Yaşam Kemal; Karaca, Nilay; Tığlıoğlu, Mesut

    2016-12-01

    Male hypogonadism is defined as the deficiency of testosterone or sperm production synthesized by testicles or the deficiency of both. The reasons for hypogonadism may be primary, meaning testicular or secondary, meaning hypothalamohypophyseal. In hypogonadotropic hypogonadism (HH), there is indeficiency in gonadotropic hormones due to hypothalamic or hypophyseal reasons. Gonadotropin-releasing hormone (GnRH) is an important stimulant in releasing follicular stimulant hormone (FSH), mainly luteinizing hormone (LH). GnRH omitted is under the effect of many hormonal or stimulating factors. Kisspeptin is present in many places of the body, mostly in hypothalamic anteroventral periventricular nucleus and arcuate nucleus. Kisspeptin has a suppressor effect on the metastasis of many tumors such as breast cancer and malign melanoma metastases, and is called "metastin" for this reason. Kisspeptin is a strong stimulant of GnRH. In idiopathic hypogonadotropic hypogonadism (IHH) etiology, there is gonadotropic hormone release indeficiency which cannot be clearly described. A total of 30 male hypogonatropic hypogonadism diagnosed patients over 30 years of age who have applied to Haydarpasa Education Hospital Endocrinology and Metabolic Diseases Service were included in the study. Compared to the control group, the effect of kisspeptin on male patients with hypogonatropic hypogonadism and on insulin resistance developing in hypogonadism patients was investigated in our study. A statistically significant difference was detected between average kisspeptin measurements of the groups (p < 0.01). Kisspeptin measurement of the cases in the patient group were detected significantly high. No statistically significant relation was detected among kisspeptin and LH/FSH levels. Although a positive low relation was detected between kisspeptin measurements of patient group cases and homeostasis model assessment of insulin resistance (HOMA-IR) measurements, this relation was statistically insignificant. When the patient and control groups were compared for HOMA-IR, no statistically significant difference was detected. The reason for high kisspeptin levels in the patient group compared to the control group makes us consider that there may be a GPR54 resistance or GnRH neuronal transfer pathway defect. When patients and control groups were compared for HOMA-IR, the difference was not statistically significant. It is considered that kisspeptin is one of the reasons for hypogonatropic hypogonadism and has less effect on insulin resistance.

  16. The effect of swab sample choice on the detection of avian influenza in apparently healthy wild ducks

    USGS Publications Warehouse

    Ip, Hon S.; Dusek, Robert J.; Heisey, Dennis M.

    2012-01-01

    Historically, avian influenza viruses have been isolated from cloacal swab specimens, but recent data suggest that the highly pathogenic avian influenza (HPAI) H5N1 virus can be better detected from respiratory tract specimens. To better understand how swab sample type affects the detection ability of low pathogenic avian influenza (LPAI) viruses we collected and tested four swab types: oropharyngeal swabs (OS), cloacal swabs (CS), the two swab types combined in the laboratory (LCS), and the two swab types combined in the field (FCS). A total of 1968 wild waterfowl were sampled by each of these four methods and tested for avian influenza virus using matrix gene reverse-transcription (RT)-PCR. The highest detection rate occurred with the FCS (4.3%) followed by the CS (4.0%). Although this difference did not achieve traditional statistical significance, Bayesian analysis indicated that FCS was superior to CS with an 82% probability. The detection rates for both the LCS (2.4%) and the OS (0.4%) were significantly different from the FCS. In addition, every swab type that was matrix RT-PCR positive was also tested for recovery of viable influenza virus. This protocol reduced the detection rate, but the ordering of swab types remained the same: 1.73% FCS, 1.42% CS, 0.81% LCS, and 0% OS. Our data suggest that the FCS performed at least as well as any other swab type for detecting LPAI viruses in the wild ducks tested. When considering recent studies showing that HPAI H5N1 can be better detected in the respiratory tract, the FCS is the most appropriate sample to collect for HPAI H5N1 surveillance while not compromising LPAI studies.

  17. Blurred digital mammography images: an analysis of technical recall and observer detection performance.

    PubMed

    Ma, Wang Kei; Borgen, Rita; Kelly, Judith; Millington, Sara; Hilton, Beverley; Aspin, Rob; Lança, Carla; Hogg, Peter

    2017-03-01

    Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ 2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ 2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur. Advances in knowledge: This research proposes the first observer standard for the visual detection of blurring.

  18. Blurred digital mammography images: an analysis of technical recall and observer detection performance

    PubMed Central

    Borgen, Rita; Kelly, Judith; Millington, Sara; Hilton, Beverley; Aspin, Rob; Lança, Carla; Hogg, Peter

    2017-01-01

    Objective: Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. Methods: 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. Results: The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. Conclusion: According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur. Advances in knowledge: This research proposes the first observer standard for the visual detection of blurring. PMID:28134567

  19. Selective sentinel node biopsy after intratumour administration of radiotracer in breast cancer patients treated with neoadjuvant chemotherapy in relation to the level of tumour response.

    PubMed

    Díaz-Expósito, R; Martí-Bonmatí, L; Burgués, O; Casáns-Tormo, I; Bermejo-de Las Heras, B; Julve-Parreño, A; Caballero-Garate, A

    Our objective was to analyse the accuracy of the sentinel node biopsy, taking into consideration the scintigraphy detection rate after the intratumoural administration of the radiopharmaceutical in patients with breast cancer who received neoadjuvant chemotherapy. The study included 60 patients with a diagnosis of invasive breast carcinoma, stage T1-T3, who received treatment with neoadjuvant chemotherapy, and were subsequently subjected to breast surgery and sentinel node biopsy after intra-tumour administration of the radiopharmaceutical. Scintigraphic detection of some sentinel node was achieved in 55/60 patients (91.6%). When those cases that received a second injection of the radiopharmaceutical, performed peri-areolarly due to a lack of tracer migration, were excluded, the detection rate dropped to 70% (42/60). When the detection of sentinel node, or its absence, was compared in those 42 patients, no differences were found with age, laterality-location of the lesion, size pre- and post-neoadjuvant chemotherapy, histological grade, or immunohistochemical profile. There were significant differences when comparing the groups according to the degree of pathological tumour response, both with the Miller-Payne system (non-detection 44.4%-detection 16.7%, p = 0.003) as well as the residual cancer burden (72.2%-28.6%, p<0.01). The scintigraphic detection of the sentinel node after intratumoural administration of the radiopharmaceutical in patients with breast cancer who received neoadjuvant chemotherapy was below the optimal value, and sometimes a further, peri-areolar, injection was necessary, probably in relation to an alteration in the lymphatic drainage pathways. There was a significant inverse relationship between the detection of the sentinel node and level of pathological tumour response. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  20. WDR1 and CLNK gene polymorphisms correlate with serum glucose and high-density lipoprotein levels in Tibetan gout patients.

    PubMed

    Lan, Bing; Chen, Peng; Jiri, Mutu; He, Na; Feng, Tian; Liu, Kai; Jin, Tianbo; Kang, Longli

    2016-03-01

    Current evidence suggests heredity and metabolic syndrome contributes to gout progression. Specifically, the WDR1 and CLNK genes may play a role in gout progression in European ancestry populations. However, no studies have focused on Chinese populations, especially Tibetan individuals. This study aims to determine whether variations in these two genes correlate with gout-related indices in Chinese-Tibetan gout patients. Eleven single-nucleotide polymorphisms in the WDR1 and CLNK genes were detected in 319 Chinese-Tibetan gout patients and 318 controls. We used one-way analysis of variance to evaluate the polymorphisms' effects on gout based on mean serum levels of metabolism indicators, such as albumin, glucose (GLU), triglycerides, cholesterol, high-density lipoproteins (HDL-C), creatinine, and uric acid, from fasting venous blood samples. All p values were Bonferroni corrected. Polymorphisms of the WDR1 and CLNK genes affected multiple risk factors for gout development. Significant differences in serum GLU levels were detected between different genotypic groups with WDRI polymorphisms rs4604059 (p = 0.005) and rs12498927 (p = 0.005). In addition, significant differences in serum HDL-C levels were detected between different genotypic groups with the CLNK polymorphism rs2041215 (p = 0.001). Polymorphisms of CLNK also affected levels of albumin, triglycerides, and creatinine. This study is the first to investigate and identify positive correlations between WDR1 and CLNK gene polymorphisms in Chinese-Tibetan populations. Our findings provide significant evidence for the effect of genetic polymorphisms on gout-related factors in Chinese-Tibetan populations.

  1. A new 2D segmentation method based on dynamic programming applied to computer aided detection in mammography.

    PubMed

    Timp, Sheila; Karssemeijer, Nico

    2004-05-01

    Mass segmentation plays a crucial role in computer-aided diagnosis (CAD) systems for classification of suspicious regions as normal, benign, or malignant. In this article we present a robust and automated segmentation technique--based on dynamic programming--to segment mass lesions from surrounding tissue. In addition, we propose an efficient algorithm to guarantee resulting contours to be closed. The segmentation method based on dynamic programming was quantitatively compared with two other automated segmentation methods (region growing and the discrete contour model) on a dataset of 1210 masses. For each mass an overlap criterion was calculated to determine the similarity with manual segmentation. The mean overlap percentage for dynamic programming was 0.69, for the other two methods 0.60 and 0.59, respectively. The difference in overlap percentage was statistically significant. To study the influence of the segmentation method on the performance of a CAD system two additional experiments were carried out. The first experiment studied the detection performance of the CAD system for the different segmentation methods. Free-response receiver operating characteristics analysis showed that the detection performance was nearly identical for the three segmentation methods. In the second experiment the ability of the classifier to discriminate between malignant and benign lesions was studied. For region based evaluation the area Az under the receiver operating characteristics curve was 0.74 for dynamic programming, 0.72 for the discrete contour model, and 0.67 for region growing. The difference in Az values obtained by the dynamic programming method and region growing was statistically significant. The differences between other methods were not significant.

  2. Detection and attribution of vegetation greening trend in China over the last 30 years

    DOE PAGES

    Piao, Shilong; Yin, Guodong; Tan, Jianguang; ...

    2014-11-04

    The reliable detection and attribution of changes in vegetation growth is a prerequisite for the development of strategies for the sustainable management of ecosystems. This is an extraordinary challenge. To our knowledge, this study is the first to comprehensively detect and attribute a greening trend in China over the last three decades. Here, we use three different satellite-derived Leaf Area Index (LAI) datasets for detection as well as five different process-based ecosystem models for attribution. Rising atmospheric CO 2 concentration and nitrogen deposition are identified as the most likely causes of the greening trend in China, explaining 85% and 41%more » of the average growing-season LAI trend (LAI GS) estimated by satellite datasets (average trend of 0.0070yr -1, ranging from 0.0035yr -1 to 0.0127yr -1), respectively. The contribution of nitrogen deposition is more clearly seen in southern China than in the north of the country. Models disagree about the contribution of climate change alone to the trend in LAI GS at the country scale (one model shows a significant increasing trend, whereas two others show significant decreasing trends). However, the models generally agree on the negative impacts of climate change in north China and Inner Mongolia and the positive impact in the Qinghai-Xizang plateau. Provincial forest area change tends to be significantly correlated with the trend of LAI GS (P<0.05), and marginally significantly (P=0.07) correlated with the residual of LAI(GS) trend, calculated as the trend observed by satellite minus that estimated by models through considering the effects of climate change, rising CO 2 concentration and nitrogen deposition, across different provinces. In conclusion, this result highlights the important role of China's afforestation program in explaining the spatial patterns of trend in vegetation growth.« less

  3. Detection and attribution of vegetation greening trend in China over the last 30 years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piao, Shilong; Yin, Guodong; Tan, Jianguang

    The reliable detection and attribution of changes in vegetation growth is a prerequisite for the development of strategies for the sustainable management of ecosystems. This is an extraordinary challenge. To our knowledge, this study is the first to comprehensively detect and attribute a greening trend in China over the last three decades. Here, we use three different satellite-derived Leaf Area Index (LAI) datasets for detection as well as five different process-based ecosystem models for attribution. Rising atmospheric CO 2 concentration and nitrogen deposition are identified as the most likely causes of the greening trend in China, explaining 85% and 41%more » of the average growing-season LAI trend (LAI GS) estimated by satellite datasets (average trend of 0.0070yr -1, ranging from 0.0035yr -1 to 0.0127yr -1), respectively. The contribution of nitrogen deposition is more clearly seen in southern China than in the north of the country. Models disagree about the contribution of climate change alone to the trend in LAI GS at the country scale (one model shows a significant increasing trend, whereas two others show significant decreasing trends). However, the models generally agree on the negative impacts of climate change in north China and Inner Mongolia and the positive impact in the Qinghai-Xizang plateau. Provincial forest area change tends to be significantly correlated with the trend of LAI GS (P<0.05), and marginally significantly (P=0.07) correlated with the residual of LAI(GS) trend, calculated as the trend observed by satellite minus that estimated by models through considering the effects of climate change, rising CO 2 concentration and nitrogen deposition, across different provinces. In conclusion, this result highlights the important role of China's afforestation program in explaining the spatial patterns of trend in vegetation growth.« less

  4. The simple ears of noctuoid moths are tuned to the calls of their sympatric bat community.

    PubMed

    ter Hofstede, Hannah M; Goerlitz, Holger R; Ratcliffe, John M; Holderied, Marc W; Surlykke, Annemarie

    2013-11-01

    Insects with bat-detecting ears are ideal animals for investigating sensory system adaptations to predator cues. Noctuid moths have two auditory receptors (A1 and A2) sensitive to the ultrasonic echolocation calls of insectivorous bats. Larger moths are detected at greater distances by bats than smaller moths. Larger moths also have lower A1 best thresholds, allowing them to detect bats at greater distances and possibly compensating for their increased conspicuousness. Interestingly, the sound frequency at the lowest threshold is lower in larger than in smaller moths, suggesting that the relationship between threshold and size might vary across frequencies used by different bat species. Here, we demonstrate that the relationships between threshold and size in moths were only significant at some frequencies, and these frequencies differed between three locations (UK, Canada and Denmark). The relationships were more likely to be significant at call frequencies used by proportionately more bat species in the moths' specific bat community, suggesting an association between the tuning of moth ears and the cues provided by sympatric predators. Additionally, we found that the best threshold and best frequency of the less sensitive A2 receptor are also related to size, and that these relationships hold when controlling for evolutionary relationships. The slopes of best threshold versus size differ, however, such that the difference in threshold between A1 and A2 is greater for larger than for smaller moths. The shorter time from A1 to A2 excitation in smaller than in larger moths could potentially compensate for shorter absolute detection distances in smaller moths.

  5. Polarization effects in cutaneous autofluorescent spectra

    NASA Astrophysics Data System (ADS)

    Borisova, E.; Angelova, L.; Jeliazkova, Al.; Genova, Ts.; Pavlova, E.; Troyanova, P.; Avramov, L.

    2014-05-01

    Used polarized light for fluorescence excitation one could obtain response related to the anisotropy features of extracellular matrix. The fluorophore anisotropy is attenuated during lesions' growth and level of such decrease could be correlated with the stage of tumor development. Our preliminary investigations are based on in vivo point-by-point measurements of excitation-emission matrices (EEM) from healthy volunteers skin on different ages and from different anatomical places using linear polarizer and analyzer for excitation and emission light detected. Measurements were made using spectrofluorimeter FluoroLog 3 (HORIBA Jobin Yvon, France) with fiber-optic probe in steady-state regime using excitation in the region of 280-440 nm. Three different situations were evaluated and corresponding excitation-emission matrices were developed - with parallel and perpendicular positions for linear polarizer and analyzer, and without polarization of excitation and fluorescence light detected from a forearm skin surface. The fluorescence spectra obtained reveal differences in spectral intensity, related to general attenuation, due to filtering effects of used polarizer/analyzer couple. Significant spectral shape changes were observed for the complex autofluorescence signal detected, which correlated with collagen and protein cross-links fluorescence, that could be addressed to the tissue extracellular matrix and general condition of the skin investigated, due to morphological destruction during lesions' growth. A correlation between volunteers' age and the fluorescence spectra detected was observed during our measurements. Our next step is to increase developed initial database and to evaluate all sources of intrinsic fluorescent polarization effects and found if they are significantly altered from normal skin to cancerous state of the tissue, this way to develop a non-invasive diagnostic tool for dermatological practice.

  6. Auditory false perception in schizophrenia: Development and validation of auditory signal detection task.

    PubMed

    Chhabra, Harleen; Sowmya, Selvaraj; Sreeraj, Vanteemar S; Kalmady, Sunil V; Shivakumar, Venkataram; Amaresha, Anekal C; Narayanaswamy, Janardhanan C; Venkatasubramanian, Ganesan

    2016-12-01

    Auditory hallucinations constitute an important symptom component in 70-80% of schizophrenia patients. These hallucinations are proposed to occur due to an imbalance between perceptual expectation and external input, resulting in attachment of meaning to abstract noises; signal detection theory has been proposed to explain these phenomena. In this study, we describe the development of an auditory signal detection task using a carefully chosen set of English words that could be tested successfully in schizophrenia patients coming from varying linguistic, cultural and social backgrounds. Schizophrenia patients with significant auditory hallucinations (N=15) and healthy controls (N=15) performed the auditory signal detection task wherein they were instructed to differentiate between a 5-s burst of plain white noise and voiced-noise. The analysis showed that false alarms (p=0.02), discriminability index (p=0.001) and decision bias (p=0.004) were significantly different between the two groups. There was a significant negative correlation between false alarm rate and decision bias. These findings extend further support for impaired perceptual expectation system in schizophrenia patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. LROC Investigation of Three Strategies for Reducing the Impact of Respiratory Motion on the Detection of Solitary Pulmonary Nodules in SPECT

    NASA Astrophysics Data System (ADS)

    Smyczynski, Mark S.; Gifford, Howard C.; Dey, Joyoni; Lehovich, Andre; McNamara, Joseph E.; Segars, W. Paul; King, Michael A.

    2016-02-01

    The objective of this investigation was to determine the effectiveness of three motion reducing strategies in diminishing the degrading impact of respiratory motion on the detection of small solitary pulmonary nodules (SPNs) in single-photon emission computed tomographic (SPECT) imaging in comparison to a standard clinical acquisition and the ideal case of imaging in the absence of respiratory motion. To do this nonuniform rational B-spline cardiac-torso (NCAT) phantoms based on human-volunteer CT studies were generated spanning the respiratory cycle for a normal background distribution of Tc-99 m NeoTect. Similarly, spherical phantoms of 1.0-cm diameter were generated to model small SPN for each of the 150 uniquely located sites within the lungs whose respiratory motion was based on the motion of normal structures in the volunteer CT studies. The SIMIND Monte Carlo program was used to produce SPECT projection data from these. Normal and single-lesion containing SPECT projection sets with a clinically realistic Poisson noise level were created for the cases of 1) the end-expiration (EE) frame with all counts, 2) respiration-averaged motion with all counts, 3) one fourth of the 32 frames centered around EE (Quarter Binning), 4) one half of the 32 frames centered around EE (Half Binning), and 5) eight temporally binned frames spanning the respiratory cycle. Each of the sets of combined projection data were reconstructed with RBI-EM with system spatial-resolution compensation (RC). Based on the known motion for each of the 150 different lesions, the reconstructed volumes of respiratory bins were shifted so as to superimpose the locations of the SPN onto that in the first bin (Reconstruct and Shift). Five human observers performed localization receiver operating characteristics (LROC) studies of SPN detection. The observer results were analyzed for statistical significance differences in SPN detection accuracy among the three correction strategies, the standard acquisition, and the ideal case of the absence of respiratory motion. Our human-observer LROC determined that Quarter Binning and Half Binning strategies resulted in SPN detection accuracy statistically significantly below ( ) that of standard clinical acquisition, whereas the Reconstruct and Shift strategy resulted in a detection accuracy not statistically significantly different from that of the ideal case. This investigation demonstrates that tumor detection based on acquisitions associated with less than all the counts which could potentially be employed may result in poorer detection despite limiting the motion of the lesion. The Reconstruct and Shift method results in tumor detection that is equivalent to ideal motion correction.

  8. Evaluation of Next-Generation Vision Testers for Aeromedical Certification of Aviation Personnel

    DTIC Science & Technology

    2009-07-01

    measure distant, intermediate, and near acuity. The slides are essentially abbreviated versions of the Early Treatment for Diabetic Retinopathy Study...over, requiring intermediate vision testing and 12 were color deficient. Analysis was designed to detect statistically significant differences between...Vertical Phoria (Right & Left Hyperphoria) Test scores from each of the vision testers were collated and analyzed. Analysis was designed to detect

  9. Effect of Mild Cognitive Impairment and Alzheimer Disease on Auditory Steady-State Responses

    PubMed Central

    Shahmiri, Elaheh; Jafari, Zahra; Noroozian, Maryam; Zendehbad, Azadeh; Haddadzadeh Niri, Hassan; Yoonessi, Ali

    2017-01-01

    Introduction: Mild Cognitive Impairment (MCI), a disorder of the elderly people, is difficult to diagnose and often progresses to Alzheimer Disease (AD). Temporal region is one of the initial areas, which gets impaired in the early stage of AD. Therefore, auditory cortical evoked potential could be a valuable neuromarker for detecting MCI and AD. Methods: In this study, the thresholds of Auditory Steady-State Response (ASSR) to 40 Hz and 80 Hz were compared between Alzheimer Disease (AD), MCI, and control groups. A total of 42 patients (12 with AD, 15 with MCI, and 15 elderly normal controls) were tested for ASSR. Hearing thresholds at 500, 1000, and 2000 Hz in both ears with modulation rates of 40 and 80 Hz were obtained. Results: Significant differences in normal subjects were observed in estimated ASSR thresholds with 2 modulation rates in 3 frequencies in both ears. However, the difference was significant only in 500 Hz in the MCI group, and no significant differences were observed in the AD group. In addition, significant differences were observed between the normal subjects and AD patients with regard to the estimated ASSR thresholds with 2 modulation rates and 3 frequencies in both ears. A significant difference was observed between the normal and MCI groups at 2000 Hz, too. An increase in estimated 40 Hz ASSR thresholds in patients with AD and MCI suggests neural changes in auditory cortex compared to that in normal ageing. Conclusion: Auditory threshold estimation with low and high modulation rates by ASSR test could be a potentially helpful test for detecting cognitive impairment. PMID:29158880

  10. Endoscopic vs. tactile evaluation of subgingival calculus.

    PubMed

    Osborn, Joy B; Lenton, Patricia A; Lunos, Scott A; Blue, Christine M

    2014-08-01

    Endoscopic technology has been developed to facilitate imagery for use during diagnostic and therapeutic phases of periodontal care. The purpose of this study was to compare the level of subgingival calculus detection using a periodontal endoscope with that of conventional tactile explorer in periodontitis subjects. A convenience sample of 26 subjects with moderate periodontitis in at least 2 quadrants was recruited from the University of Minnesota School of Dentistry to undergo quadrant scaling and root planing. One quadrant from each subject was randomized for tactile calculus detection alone and the other quadrant for tactile detection plus the Perioscope ™ (Perioscopy Inc., Oakland, Cali). A calculus index on a 0 to 3 score was performed at baseline and at 2 post-scaling and root planing visits. Sites where calculus was detected at visit 1 were retreated. T-tests were used to determine within-subject differences between Perioscope™ and tactile measures, and changes in measures between visits. Significantly more calculus was detected using the Perioscope™ vs. tactile explorer for all 3 subject visits (p<0.005). Mean changes (reduction) in calculus detection from baseline to visit 1 were statistically significant for both the Perioscope™ and tactile quadrants (p<0.0001). However, further reductions in calculus detection from visit 1 to visit 2 was only significant for the Perioscope™ quadrant (p<0.025), indicating that this methodology was able to more precisely detect calculus at this visit. It was concluded that the addition of a visual component to calculus detection via the Perioscope™ was most helpful in the re-evaluation phase of periodontal therapy. Copyright © 2014 The American Dental Hygienists’ Association.

  11. Unobtrusive Detection of Mild Cognitive Impairment in Older Adults Through Home Monitoring*

    PubMed Central

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2016-01-01

    The early detection of dementias such as Alzheimer’s disease can in some cases reverse, stop or slow cognitive decline and in general greatly reduce the burden of care. This is of increasing significance as demographic studies are warning of an aging population in North America and worldwide. Various smart homes and systems have been developed to detect cognitive decline through continuous monitoring of high risk individuals. However, the majority of these smart homes and systems use a number of predefined heuristics to detect changes in cognition, which has been demonstrated to focus on the idiosyncratic nuances of the individual subjects and thus does not generalize. In this paper, we address this problem by building generalized linear models of home activity of subjects monitored using unobtrusive sensing technologies. We use inhomogenous Poisson processes to model the presence of subjects within different rooms throughout the day. We employ an information theoretic approach to compare the activity distributions learned, and we observe significant statistical differences between the cognitively intact and impaired subjects. Using a simple thresholding approach, we were able to detect mild cognitive impairment in older adults with an average area under the ROC curve of 0.716 and an average area under the precision-recall curve of 0.706 using distributions estimated over time windows of 12 weeks. PMID:26841424

  12. Is health screening beneficial for early detection and prognostic improvement in pancreatic cancer?

    PubMed

    Kim, Eun Ran; Bae, Sun Youn; Lee, Kwang Hyuk; Lee, Kyu Taek; Son, Hee Jung; Rhee, Jong Chul; Lee, Jong Kyun

    2011-06-01

    The aim of this study was to evaluate the usefulness of health screening for early detection and improved prognosis in pancreatic cancer. Between 1995 and 2008, 176,361 examinees visited the Health Promotion Center (HPC). Twenty patients diagnosed with pancreatic cancer were enrolled. During the same period, 40 patients were randomly selected from 2,202 patients diagnosed with pancreatic cancer at the Out Patient Clinic (OPC) for comparison. Within the HPC group, 10 patients were initially suspected of having pancreatic cancer following abnormal ultrasonographic findings, and 9 patients had suspected cases following the detection of elevated serum CA 19-9. The curative resection rate was higher in the HPC group than in the OPC group (p=0.011). The median survival was longer in the HPC group than in the OPC group (p=0.000). However, there was no significant difference in the 3-year survival rate between the two groups. Asymptomatic patients (n=6/20) in the HPC group showed better curative resection and survival rates than symptomatic patients. However, the difference was not statistically significant. Health screening is somewhat helpful for improving the curative resection rate and median survival of patients with pancreatic cancer detected by screening tests. However, the benefit of this method in improving long-term survival is limited by how early the cancer is detected.

  13. Unobtrusive Detection of Mild Cognitive Impairment in Older Adults Through Home Monitoring.

    PubMed

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2017-03-01

    The early detection of dementias such as Alzheimer's disease can in some cases reverse, stop, or slow cognitive decline and in general greatly reduce the burden of care. This is of increasing significance as demographic studies are warning of an aging population in North America and worldwide. Various smart homes and systems have been developed to detect cognitive decline through continuous monitoring of high risk individuals. However, the majority of these smart homes and systems use a number of predefined heuristics to detect changes in cognition, which has been demonstrated to focus on the idiosyncratic nuances of the individual subjects, and thus, does not generalize. In this paper, we address this problem by building generalized linear models of home activity of older adults monitored using unobtrusive sensing technologies. We use inhomogenous Poisson processes to model the presence of the recruited older adults within different rooms throughout the day. We employ an information theoretic approach to compare the generalized linear models learned, and we observe significant statistical differences between the cognitively intact and impaired older adults. Using a simple thresholding approach, we were able to detect mild cognitive impairment in older adults with an average area under the ROC curve of 0.716 and an average area under the precision-recall curve of 0.706 using activity models estimated over a time window of 12 weeks.

  14. Diagnostic performance of a commercial immunoblot assay for myositis antibody testing.

    PubMed

    Bundell, Chris; Rojana-Udomsart, Arada; Mastaglia, Frank; Hollingsworth, Peter; McLean-Tooke, Andrew

    2016-06-01

    The objective of this study was to establish a population based reference range for a commercial immunoblot assay detecting myositis specific autoantibodies (MSAs) and myositis associated autoantibodies (MAAs), and to assess the diagnostic performance of this reference range against the manufacturer's recommended ranges in a myositis patient cohort. A total of 124 patients from a myositis cohort and 197 healthy controls were serologically assessed using a commercial immunoblot containing eleven autoantigens (Jo-1, EJ, OJ, PL7, PL12, Mi-2, SRP, Ku, PMScl75, PMScl100 and Ro52) according to the manufacturer's instructions. Use of the manufacturer's reference ranges resulted in detection of MSAs in 19.4% of myositis patients and 9.1% of controls; MAAs were detected in 41.1% of myositis patients and 14.2% of controls. Reference values derived from the healthy control population resulted in significant differences in cut-off values for some autoantibodies, particularly Ro52 and PMScl75. Use of local reference ranges reduced detection of MSAs to 16.9% of myositis patients and 3% of healthy controls, with MAAs 23.4% of patients and 2% of healthy controls. Application of population based reference ranges resulted in significant differences in detection of MSAs and MAAs compared to the manufacturer's recommended ranges. Cut-off levels should be assessed to ensure suitability for the population tested. Copyright © 2016. Published by Elsevier B.V.

  15. Detection of cow milk adulteration in yak milk by ELISA.

    PubMed

    Ren, Q R; Zhang, H; Guo, H Y; Jiang, L; Tian, M; Ren, F Z

    2014-10-01

    In the current study, a simple, sensitive, and specific ELISA assay using a high-affinity anti-bovine β-casein monoclonal antibody was developed for the rapid detection of cow milk in adulterated yak milk. The developed ELISA was highly specific and could be applied to detect bovine β-casein (10-8,000 μg/mL) and cow milk (1:1,300 to 1:2 dilution) in yak milk. Cross-reactivity was <1% when tested against yak milk. The linear range of adulterant concentration was 1 to 80% (vol/vol) and the minimum detection limit was 1% (vol/vol) cow milk in yak milk. Different treatments, including heating, acidification, and rennet addition, did not interfere with the assay. Moreover, the results were highly reproducible (coefficient of variation <10%) and we detected no significant differences between known and estimated values. Therefore, this assay is appropriate for the routine analysis of yak milk adulterated with cow milk. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Irrigation scheduling, freeze warning and soil salinity detecting. [in Cameron County Texas

    NASA Technical Reports Server (NTRS)

    Wiegand, C. L. (Principal Investigator)

    1975-01-01

    The author has identified the following significant results. Correlations of multispectral scanner (MSS) digital data differences between vegetated and bare soil areas with salinity levels from the eight saline areas using MSS bands seven and ten in the infrared region were significant. Correlations were derived for Cameron County, Texas. Detection of saline soils may be possible, using either film density readings or multispectral scanner data, when the lower reflectance of vegetation on highly saline soil and the higher reflectance of vegetation on lower saline soil are considered by using film on MSS contrasts between vegetation and bare soil.

  17. Reflex muscle contraction in anterior shoulder instability.

    PubMed

    Wallace, D A; Beard, D J; Gill, R H; Eng, B; Carr, A J

    1997-01-01

    Reduced proprioception may contribute to recurrent anterior shoulder instability. Twelve patients with unilateral shoulder instability were investigated for evidence of deficient proprioception with an activated pneumatic cylinder and surface electromyography electrodes; the contralateral normal shoulder was used as a control. The latency between onset of movement and the detection of muscle contraction was used as an index of proprioception. No significant difference in muscle contraction latency was detected between the stable and unstable shoulders, suggesting that there was no significant defect in muscular reflex activity. This study does not support the use proprioception-enhancing physiotherapy in the treatment of posttraumatic anterior shoulder instability.

  18. [Asymmetry of brain lesions and immunobiologic reactivity].

    PubMed

    Semenov, S F; Chuprikov, A P

    1975-01-01

    The authors compare some clinico-psychopathological traits in the development and frequency of detected antibrain antibodies and allergical states in epilepsy with a different lateralization in the hemispheres. In a sinistral localization of the lesion there is a significant increase of an unfavourable development of the disease and a more frequent detection of antibodies to the homologous brain. In a dextral localization there is a relatively favourable development of the basic disorder. The authors discuss the influence of the sex factor on the immunobiological indices and the lateralization of the hemisphere. A theory is suggested that the left and right hemispheres are involved in different ways in the different links of immunity, and their pathology may provoke different changes in the body reactivity.

  19. Detection of Nonverbal Synchronization through Phase Difference in Human Communication

    PubMed Central

    Kwon, Jinhwan; Ogawa, Ken-ichiro; Ono, Eisuke; Miyake, Yoshihiro

    2015-01-01

    Nonverbal communication is an important factor in human communication, and body movement synchronization in particular is an important part of nonverbal communication. Some researchers have analyzed body movement synchronization by focusing on changes in the amplitude of body movements. However, the definition of “body movement synchronization” is still unclear. From a theoretical viewpoint, phase difference is the most important factor in synchronization analysis. Therefore, there is a need to measure the synchronization of body movements using phase difference. The purpose of this study was to provide a quantitative definition of the phase difference distribution for detecting body movement synchronization in human communication. The phase difference distribution was characterized using four statistical measurements: density, mean phase difference, standard deviation (SD) and kurtosis. To confirm the effectiveness of our definition, we applied it to human communication in which the roles of speaker and listener were defined. Specifically, we examined the difference in the phase difference distribution between two different communication situations: face-to-face communication with visual interaction and remote communication with unidirectional visual perception. Participant pairs performed a task supposing lecture in the face-to-face communication condition and in the remote communication condition via television. Throughout the lecture task, we extracted a set of phase differences from the time-series data of the acceleration norm of head nodding motions between two participants. Statistical analyses of the phase difference distribution revealed the characteristics of head nodding synchronization. Although the mean phase differences in synchronized head nods did not differ significantly between the conditions, there were significant differences in the densities, the SDs and the kurtoses of the phase difference distributions of synchronized head nods. These results show the difference in nonverbal synchronization between different communication types. Our study indicates that the phase difference distribution is useful in detecting nonverbal synchronization in various human communication situations. PMID:26208100

  20. Detection of Nonverbal Synchronization through Phase Difference in Human Communication.

    PubMed

    Kwon, Jinhwan; Ogawa, Ken-ichiro; Ono, Eisuke; Miyake, Yoshihiro

    2015-01-01

    Nonverbal communication is an important factor in human communication, and body movement synchronization in particular is an important part of nonverbal communication. Some researchers have analyzed body movement synchronization by focusing on changes in the amplitude of body movements. However, the definition of "body movement synchronization" is still unclear. From a theoretical viewpoint, phase difference is the most important factor in synchronization analysis. Therefore, there is a need to measure the synchronization of body movements using phase difference. The purpose of this study was to provide a quantitative definition of the phase difference distribution for detecting body movement synchronization in human communication. The phase difference distribution was characterized using four statistical measurements: density, mean phase difference, standard deviation (SD) and kurtosis. To confirm the effectiveness of our definition, we applied it to human communication in which the roles of speaker and listener were defined. Specifically, we examined the difference in the phase difference distribution between two different communication situations: face-to-face communication with visual interaction and remote communication with unidirectional visual perception. Participant pairs performed a task supposing lecture in the face-to-face communication condition and in the remote communication condition via television. Throughout the lecture task, we extracted a set of phase differences from the time-series data of the acceleration norm of head nodding motions between two participants. Statistical analyses of the phase difference distribution revealed the characteristics of head nodding synchronization. Although the mean phase differences in synchronized head nods did not differ significantly between the conditions, there were significant differences in the densities, the SDs and the kurtoses of the phase difference distributions of synchronized head nods. These results show the difference in nonverbal synchronization between different communication types. Our study indicates that the phase difference distribution is useful in detecting nonverbal synchronization in various human communication situations.

  1. Can Handheld Thermal Imaging Technology Improve Detection of Poachers in African Bushveldt?

    PubMed Central

    Dandy, Shantelle; Stubbs, Hannah; MacTavish, Dougal; MacTavish, Lynne

    2015-01-01

    Illegal hunting (poaching) is a global threat to wildlife. Anti-poaching initiatives are making increasing use of technology, such as infrared thermography (IRT), to support traditional foot and vehicle patrols. To date, the effectiveness of IRT for poacher location has not been tested under field conditions, where thermal signatures are often complex. Here, we test the hypothesis that IRT will increase the distance over which a poacher hiding in African scrub bushveldt can be detected relative to a conventional flashlight. We also test whether any increase in effectiveness is related to the cost and complexity of the equipment by comparing comparatively expensive (22000 USD) and relatively inexpensive (2000 USD) IRT devices. To test these hypotheses we employ a controlled, fully randomised, double-blind procedure to find a poacher in nocturnal field conditions in African bushveldt. Each of our 27 volunteer observers walked three times along a pathway using one detection technology on each pass in randomised order. They searched a prescribed search area of bushveldt within which the target was hiding. Hiding locations were pre-determined, randomised, and changed with each pass. Distances of first detection and positive detection were noted. All technologies could be used to detect the target. Average first detection distance for flashlight was 37.3m, improving by 19.8m to 57.1m using LIRT and by a further 11.2m to 68.3m using HIRT. Although detection distances were significantly greater for both IRTs compared to flashlight, there was no significant difference between LIRT and HIRT. False detection rates were low and there was no significant association between technology and accuracy of detection. Although IRT technology should ideally be tested in the specific environment intended before significant investment is made, we conclude that IRT technology is promising for anti-poaching patrols and that for this purpose low cost IRT units are as effective as units ten times more expensive. PMID:26110865

  2. Prevalence of antibodies against canine distemper virus and canine parvovirus among foxes and wolves from Spain.

    PubMed

    Sobrino, R; Arnal, M C; Luco, D F; Gortázar, C

    2008-01-01

    Viral diseases can influence the population dynamics of wild carnivores and can have effects on carnivore conservation. Hence, a serologic survey was conducted in an opportunistic sample of 137 foxes (Vulpes vulpes) and 37 wolves (Canis lupus) in Spain for 1997-2007 to detect antibodies against canine distemper virus (CDV) and against canine parvovirus (CPV) by indirect ELISA. Antibodies against CDV were detected in 18.7% of the analyzed animals and antibodies against CPV in 17.2%. There was no difference in antibody prevalence to CDV between both species, even in the same region (P>0.05), but there was a significant difference in antibody prevalence to CPV between foxes (5.1%) and wolves (62.2%) (P<0.05). In fox populations there was a significant difference in antibody prevalence to CDV between geographic areas (Aragón 26.4%, La Mancha 7.8%, P<0.05). In wolf populations there was significantly higher antibody prevalence against CPV (P<0.05) in Castilla y León (100%) than in the Cantabric region (53.3%). There was no significant sex or age-related difference in the antibody prevalence against CDV or CPV in foxes. These results indicate that contact with CDV is widespread among wild canid populations in Spain and that CPV is endemic in the Iberian wolf population. The implications of these results are briefly discussed.

  3. Generalized Linear Models of Home Activity for Automatic Detection of Mild Cognitive Impairment in Older Adults*

    PubMed Central

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2015-01-01

    With a globally aging population, the burden of care of cognitively impaired older adults is becoming increasingly concerning. Instances of Alzheimer’s disease and other forms of dementia are becoming ever more frequent. Earlier detection of cognitive impairment offers significant benefits, but remains difficult to do in practice. In this paper, we develop statistical models of the behavior of older adults within their homes using sensor data in order to detect the early onset of cognitive decline. Specifically, we use inhomogenous Poisson processes to model the presence of subjects within different rooms throughout the day in the home using unobtrusive sensing technologies. We compare the distributions learned from cognitively intact and impaired subjects using information theoretic tools and observe statistical differences between the two populations which we believe can be used to help detect the onset of cognitive decline. PMID:25570050

  4. Generalized Linear Models of home activity for automatic detection of mild cognitive impairment in older adults.

    PubMed

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2014-01-01

    With a globally aging population, the burden of care of cognitively impaired older adults is becoming increasingly concerning. Instances of Alzheimer's disease and other forms of dementia are becoming ever more frequent. Earlier detection of cognitive impairment offers significant benefits, but remains difficult to do in practice. In this paper, we develop statistical models of the behavior of older adults within their homes using sensor data in order to detect the early onset of cognitive decline. Specifically, we use inhomogenous Poisson processes to model the presence of subjects within different rooms throughout the day in the home using unobtrusive sensing technologies. We compare the distributions learned from cognitively intact and impaired subjects using information theoretic tools and observe statistical differences between the two populations which we believe can be used to help detect the onset of cognitive decline.

  5. Evaluation Children with Global Developmental Delay: A Prospective Study at Sultan Qaboos University Hospital, Oman

    PubMed Central

    Koul, Roshan; Al-Yahmedy, Mohammed; Al-Futaisi, Amna

    2012-01-01

    Objective A prospective study was designed to analyze risk factors and clinical features in children with global developmental delay (GDD) at our hospital. No previous data is available on GDD from Oman. Methods This study was conducted at Sultan Qaboos University Hospital from January 2008 until June 2009. All the children aged 5 years or less, referred with suspected GDD were included in the study. Data was analyzed to determine the underlying etiology. The children with neurodegenerative disease and muscular dystrophy were excluded from the study. Results One hundred and ten children, 59 males (53.6%) and 51 females (46.4%) were included in the study. The mean age at initial evaluation was 13.29 months. An underlying etiology was determined in 79 (71.8%) children. Perinatal history was associated with significant difference in detection of etiology (p=0.039). Abnormal neurological examination was a significant factor in detection of the underlying etiology. Magnetic resonance imaging (MRI) in 105 children and metabolic screening in 93 children were the most frequently ordered investigations. Abnormal imaging, MRI (p=0.001), CT scan (p=0.036) and metabolic screening (p=0.034) were significantly associated with detection of etiology. Conclusion Etiology was detected in 71.8% of the children. MRI was the most significant investigation to detect the abnormality. PMID:23071884

  6. Regression equations for sex and population detection using the lip print pattern among Egyptian and Malaysian adult.

    PubMed

    Abdel Aziz, Manal H; Badr El Dine, Fatma M M; Saeed, Nourhan M M

    2016-11-01

    Identification of sex and ethnicity has always been a challenge in the fields of forensic medicine and criminal investigations. Fingerprinting and DNA comparisons are probably the most common techniques used in this context. However, since they cannot always be used, it is necessary to apply different and less known techniques such as lip prints. Is to study the pattern of lip print in Egyptian and Malaysian populations and its relation to sex and populations difference. Also, to develop equations for sex and populations detection using lip print pattern by different populations (Egyptian and Malaysian). The sample comprised of 120 adults volunteers divided into two ethnic groups; sixty adult Egyptians (30 males and 30 females) and sixty adult Malaysians (30 males and 30 females). The lip prints were collected on a white paper. Each lip print was divided into four compartments and were classified and scored according to Suzuki and Tsuchihashi classification. Data were statistically analyzed. The results showed that type III lip print pattern (intersected grooves) was the predominant type in both the Egyptian and Malaysian populations. Type II and III were the most frequent in Egyptian males (28.3% each), while in Egyptian females type III pattern was predominant (46.7%). As regards Malaysian males, type III lip print pattern was the predominant one (41.7%), while type II lip print pattern was predominant (30.8%) in Malaysian females. Statistical analysis of different quadrants showed significant differences between males and females in the Egyptian population in the third and fourth quadrants. On the other hand, significant differences were detected only in the second quadrant between Malaysian males and females. Also, a statistically significant difference was present in the second quadrant between Egyptian and Malaysian males. Using the regression analysis, four regression equations were obtained. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  7. A correlation study between in-brace correction, compliance to spinal orthosis and health-related quality of life of patients with Adolescent Idiopathic Scoliosis

    PubMed Central

    2014-01-01

    Background It has been proposed that in-brace correction is the best guideline for prediction of the results of brace treatment for patients with Adolescent Idiopathic Scoliosis (AIS). However, bracing may be a stressful experience for patients and bracing non-compliance could be psychologically related. The purpose of this study was to assess the correlation between brace compliance, in-brace correction and QoL of patients with AIS. Methods Fifty-five patients with a diagnosis of AIS were recruited. All were female and aged 10 years or above when a brace was prescribed, none had undergone prior treatment, and all had a Risser sign of 0–2 and a Cobb angle of 25-40°. The patients were examined in three consecutive visits with 4 to 6 months between each visit. The Chinese translated Trunk Appearance Perception Scale (TAPS), the Chinese translated Brace Questionnaires (BrQ) and the Chinese translated SRS-22 Questionnaires were used in the study. The in-brace Cobb angle, vertebral rotation and trunk listing were also measured. Patients’ compliance, in-brace correction and patients’ QoL were assessed. To identify the relationship among these three areas, logistic regression model and generalized linear model were used. Result For the compliance measure, a significant difference (p = 0.008) was detected on TAPS mean score difference between Visit 1 and Visit 2 in the least compliant group (0–8 hours) and the most compliant group (17–23 hours). In addition, a significant difference (p = 0.000) was detected on BrQ mean score difference between Visit 2 and Visit 3 in the least compliant group (0–8 hours) and the most compliant group (17–23 hours). For the orthosis effectiveness measure, no significant difference was detected between the three groups of bracing hours (0–8 hours, 9–16 hours, 17–23 hours) on in-brace correction (below 40% and 40% or above). For the QoL measure, no significant difference was detected between the two different in-brace correction groups (below 40% and 40% or above) on QoL as reflected by the TAPS, BrQ and SRS-22r mean scores. Conclusion The results showed a positive relationship between patients’ brace wear compliance and patients’ QoL. Poor compliance would cause a lower QoL. PMID:24559234

  8. Variation in chemical composition and physical characteristics of cereal grains from different genotypes.

    PubMed

    Rodehutscord, Markus; Rückert, Christine; Maurer, Hans Peter; Schenkel, Hans; Schipprack, Wolfgang; Bach Knudsen, Knud Erik; Schollenberger, Margit; Laux, Meike; Eklund, Meike; Siegert, Wolfgang; Mosenthin, Rainer

    2016-01-01

    Genotypes of cereal grains, including winter barley (n = 21), maize (n = 27), oats (n = 14), winter rye (n = 22), winter triticale (n = 21) and winter wheat (n = 29), were assayed for their chemical composition and physical characteristics as part of the collaborative research project referred to as GrainUp. Genotypes of one grain species were grown on the same site, except maize. In general, concentrations of proximate nutrients were not largely different from feed tables. The coefficient of variation (CV) for the ether extract concentration of maize was high because the data pool comprised speciality maize bred for its high oil content. A subset of 8 barley, 20 rye, 20 triticale and 20 wheat samples was analysed to differ significantly in several carbohydrate fractions. Gross energy concentration of cereal grains could be predicted from proximate nutrient concentration with good accuracy. The mean lysine concentration of protein was the highest in oats (4.2 g/16 g N) and the lowest in wheat (2.7 g/16 g N). Significant differences were also detected in the concentrations of macro elements as well as iron, manganese, zinc and copper. Concentrations of arsenic, cadmium and lead were below the limit of detection. The concentration of lower inositol phosphates was low, but some inositol pentaphosphates were detected in all grains. In barley, relatively high inositol tetraphosphate concentration also was found. Intrinsic phytase activity was the highest in rye, followed by triticale, wheat, barley and maize, and it was not detectable in oats. Substantial differences were seen in the thousand seed weight, test weight, falling number and extract viscoelasticity characteristics. The study is a comprehensive overview of the composition of different cereal grain genotypes when grown on the same location. The relevance of the variation in composition for digestibility in different animal species will be subject of other communications.

  9. Effects of deracoxib or buffered aspirin on the gastric mucosa of healthy dogs.

    PubMed

    Sennello, Kathleen A; Leib, Michael S

    2006-01-01

    Use of cyclo-oxygenase-2 specific nonsteroidal anti-inflammatory drugs such as deracoxib has been advocated because of their anti-inflammatory actions and apparently low incidence of gastrointestinal adverse effects. Deracoxib will cause less endoscopically detectable gastric injury in dogs than aspirin, a nonselective nonsteroidal anti-inflammatory drug. Twenty-four random source healthy dogs. A randomized, placebo-controlled trial compared gastroscopic findings of dogs receiving placebo (q8h), aspirin (25 mg/kg PO q8h), or deracoxib (1.5 mg/kg QD, placebo ql2h) for 28 days. Gastroscopy on days -7, 6, 14, and 28 evaluated 4 regions of the stomach separately and visible lesions were scored. Dogs were observed every 8 hours for vomiting and diarrhea. Median total scores for each group were compared each day of endoscopic examination and total dog-days of vomiting and diarrhea were compared. Significance was determined at P < .05. There were significant differences in total scores of the aspirin group and both the placebo and deracoxib groups on days 6, 14, and 28. No significant differences in total scores were found between placebo and deracoxib on days 6, 14, and 28. Significant differences in dog-days of vomiting were found between the aspirin and deracoxib groups whereas no significant differences were found between the deracoxib and placebo groups. There was no detectable effect of treatment on dog-days of diarrhea. Administration of deracoxib to healthy dogs resulted in significantly lower gastric lesion scores, and fewer days of vomiting compared to aspirin, indicating that deracoxib is better tolerated than aspirin in some dogs.

  10. Automatically Detect and Track Multiple Fish Swimming in Shallow Water with Frequent Occlusion

    PubMed Central

    Qian, Zhi-Ming; Cheng, Xi En; Chen, Yan Qiu

    2014-01-01

    Due to its universality, swarm behavior in nature attracts much attention of scientists from many fields. Fish schools are examples of biological communities that demonstrate swarm behavior. The detection and tracking of fish in a school are of important significance for the quantitative research on swarm behavior. However, different from other biological communities, there are three problems in the detection and tracking of fish school, that is, variable appearances, complex motion and frequent occlusion. To solve these problems, we propose an effective method of fish detection and tracking. In this method, first, the fish head region is positioned through extremum detection and ellipse fitting; second, The Kalman filtering and feature matching are used to track the target in complex motion; finally, according to the feature information obtained by the detection and tracking, the tracking problems caused by frequent occlusion are processed through trajectory linking. We apply this method to track swimming fish school of different densities. The experimental results show that the proposed method is both accurate and reliable. PMID:25207811

  11. Automatic detection and recognition of signs from natural scenes.

    PubMed

    Chen, Xilin; Yang, Jie; Zhang, Jing; Waibel, Alex

    2004-01-01

    In this paper, we present an approach to automatic detection and recognition of signs from natural scenes, and its application to a sign translation task. The proposed approach embeds multiresolution and multiscale edge detection, adaptive searching, color analysis, and affine rectification in a hierarchical framework for sign detection, with different emphases at each phase to handle the text in different sizes, orientations, color distributions and backgrounds. We use affine rectification to recover deformation of the text regions caused by an inappropriate camera view angle. The procedure can significantly improve text detection rate and optical character recognition (OCR) accuracy. Instead of using binary information for OCR, we extract features from an intensity image directly. We propose a local intensity normalization method to effectively handle lighting variations, followed by a Gabor transform to obtain local features, and finally a linear discriminant analysis (LDA) method for feature selection. We have applied the approach in developing a Chinese sign translation system, which can automatically detect and recognize Chinese signs as input from a camera, and translate the recognized text into English.

  12. Hazardous sign detection for safety applications in traffic monitoring

    NASA Astrophysics Data System (ADS)

    Benesova, Wanda; Kottman, Michal; Sidla, Oliver

    2012-01-01

    The transportation of hazardous goods in public streets systems can pose severe safety threats in case of accidents. One of the solutions for these problems is an automatic detection and registration of vehicles which are marked with dangerous goods signs. We present a prototype system which can detect a trained set of signs in high resolution images under real-world conditions. This paper compares two different methods for the detection: bag of visual words (BoW) procedure and our approach presented as pairs of visual words with Hough voting. The results of an extended series of experiments are provided in this paper. The experiments show that the size of visual vocabulary is crucial and can significantly affect the recognition success rate. Different code-book sizes have been evaluated for this detection task. The best result of the first method BoW was 67% successfully recognized hazardous signs, whereas the second method proposed in this paper - pairs of visual words and Hough voting - reached 94% of correctly detected signs. The experiments are designed to verify the usability of the two proposed approaches in a real-world scenario.

  13. Using non-specialist observers in 4AFC human observer studies

    NASA Astrophysics Data System (ADS)

    Elangovan, Premkumar; Mackenzie, Alistair; Dance, David R.; Young, Kenneth C.; Wells, Kevin

    2017-03-01

    Virtual clinical trials (VCTs) are an emergent approach for rapid evaluation and comparison of various breast imaging technologies and techniques using computer-based modeling tools. Increasingly 4AFC (Four alternative forced choice) virtual clinical trials are used to compare detection performances of different breast imaging modalities. Most prior studies have used physicists and/or radiologists and physicists interchangeably. However, large scale use of statistically significant 4AFC observer studies is challenged by the individual time commitment and cost of such observers, often drawn from a limited local pool of specialists. This work aims to investigate whether non-specialist observers can be used to supplement such studies. A team of five specialist observers (medical physicists) and five non-specialists participated in a 4AFC study containing simulated 2D-mammography and DBT (digital breast tomosynthesis) images, produced using the OPTIMAM toolbox for VCTs. The images contained 4mm irregular solid masses and 4mm spherical targets at a range of contrast levels embedded in a realistic breast phantom background. There was no statistically significant difference between the detection performance of medical physicists and non-specialists (p>0.05). However, non-specialists took longer to complete the study than their physicist counterparts, which was statistically significant (p<0.05). Overall, the results from both observer groups indicate that DBT has a lower detectable threshold contrast than 2D-mammography for both masses and spheres, and both groups found spheres easier to detect than irregular solid masses.

  14. Olfaction and Environment: Tsimane’ of Bolivian Rainforest Have Lower Threshold of Odor Detection Than Industrialized German People

    PubMed Central

    Sorokowska, Agnieszka; Sorokowski, Piotr; Hummel, Thomas; Huanca, Tomas

    2013-01-01

    Olfactory sensitivity varies between individuals. However, data regarding cross-cultural and inter-group differences are scarce. We compared the thresholds of odor detection of the traditional society of Tsimane’ (native Amazonians of the Bolivian rainforest; n = 151) and people living in Dresden (Germany; n = 286) using “Sniffin’ Sticks” threshold subtest. Tsimane’ detected n-butanol at significantly lower concentrations than the German subjects. The distribution of thresholds of the Tsimane’ was very specific, with 25% of Tsimane’ obtaining better results in the olfactory test than any member of the German group. These data suggest that differences in olfactory sensitivity seem to be especially salient between industrialized and non-industrialized populations inhabiting different environmental conditions. We hypothesize that the possible sources of such differences are: (i) the impact of pollution which impairs the olfactory abilities of people from industrialized countries; (ii) better training of olfaction because of the higher importance of smell in traditional populations; (iii) environmental pressures shaping olfactory abilities in these populations. PMID:23922693

  15. Olfaction and environment: Tsimane' of Bolivian rainforest have lower threshold of odor detection than industrialized German people.

    PubMed

    Sorokowska, Agnieszka; Sorokowski, Piotr; Hummel, Thomas; Huanca, Tomas

    2013-01-01

    Olfactory sensitivity varies between individuals. However, data regarding cross-cultural and inter-group differences are scarce. We compared the thresholds of odor detection of the traditional society of Tsimane' (native Amazonians of the Bolivian rainforest; n = 151) and people living in Dresden (Germany; n = 286) using "Sniffin' Sticks" threshold subtest. Tsimane' detected n-butanol at significantly lower concentrations than the German subjects. The distribution of thresholds of the Tsimane' was very specific, with 25% of Tsimane' obtaining better results in the olfactory test than any member of the German group. These data suggest that differences in olfactory sensitivity seem to be especially salient between industrialized and non-industrialized populations inhabiting different environmental conditions. We hypothesize that the possible sources of such differences are: (i) the impact of pollution which impairs the olfactory abilities of people from industrialized countries; (ii) better training of olfaction because of the higher importance of smell in traditional populations; (iii) environmental pressures shaping olfactory abilities in these populations.

  16. Detection of target phonemes in spontaneous and read speech.

    PubMed

    Mehta, G; Cutler, A

    1988-01-01

    Although spontaneous speech occurs more frequently in most listeners' experience than read speech, laboratory studies of human speech recognition typically use carefully controlled materials read from a script. The phonological and prosodic characteristics of spontaneous and read speech differ considerably, however, which suggests that laboratory results may not generalise to the recognition of spontaneous speech. In the present study listeners were presented with both spontaneous and read speech materials, and their response time to detect word-initial target phonemes was measured. Responses were, overall, equally fast in each speech mode. However, analysis of effects previously reported in phoneme detection studies revealed significant differences between speech modes. In read speech but not in spontaneous speech, later targets were detected more rapidly than targets preceded by short words. In contrast, in spontaneous speech but not in read speech, targets were detected more rapidly in accented than in unaccented words and in strong than in weak syllables. An explanation for this pattern is offered in terms of characteristic prosodic differences between spontaneous and read speech. The results support claims from previous work that listeners pay great attention to prosodic information in the process of recognising speech.

  17. Proteins detection by polymer optical fibers sensitised with overlayers of block and random copolymers

    NASA Astrophysics Data System (ADS)

    El Sachat, Alexandros; Meristoudi, Anastasia; Markos, Christos; Pispas, Stergios; Riziotis, Christos

    2014-03-01

    A low cost and low complexity optical detection method of proteins is presented by employing a detection scheme based on electrostatic interactions, and implemented by sensitization of a polymer optical fibers' (POF) surface by thin overlayers of properly designed sensitive copolymer materials with predesigned charges. This method enables the fast detection of proteins having opposite charge to the overlayer, and also the effective discrimination of differently charged proteins like lysozyme (LYS) and bovine serum albumin (BSA). As sensitive materials the block and the random copolymers of the same monomers were employed, namely the block copolymer poly(styrene-b-2vinylpyridine) (PS-b- P2VP) and the corresponding random copolymer poly(styrene-r-2vinylpyridine) (PS-r-P2VP), of similar composition and molecular weights. Results show systematically different response between the block and the random copolymers, although of the same order of magnitude, drawing thus important conclusions on their applications' techno-economic aspects given that they have significantly different associated manufacturing method and costs. The use of the POF platform, in combination with those adaptable copolymer sensing materials could lead to efficient low cost bio-detection schemes.

  18. DALMATIAN: An Algorithm for Automatic Cell Detection and Counting in 3D.

    PubMed

    Shuvaev, Sergey A; Lazutkin, Alexander A; Kedrov, Alexander V; Anokhin, Konstantin V; Enikolopov, Grigori N; Koulakov, Alexei A

    2017-01-01

    Current 3D imaging methods, including optical projection tomography, light-sheet microscopy, block-face imaging, and serial two photon tomography enable visualization of large samples of biological tissue. Large volumes of data obtained at high resolution require development of automatic image processing techniques, such as algorithms for automatic cell detection or, more generally, point-like object detection. Current approaches to automated cell detection suffer from difficulties originating from detection of particular cell types, cell populations of different brightness, non-uniformly stained, and overlapping cells. In this study, we present a set of algorithms for robust automatic cell detection in 3D. Our algorithms are suitable for, but not limited to, whole brain regions and individual brain sections. We used watershed procedure to split regional maxima representing overlapping cells. We developed a bootstrap Gaussian fit procedure to evaluate the statistical significance of detected cells. We compared cell detection quality of our algorithm and other software using 42 samples, representing 6 staining and imaging techniques. The results provided by our algorithm matched manual expert quantification with signal-to-noise dependent confidence, including samples with cells of different brightness, non-uniformly stained, and overlapping cells for whole brain regions and individual tissue sections. Our algorithm provided the best cell detection quality among tested free and commercial software.

  19. Optimization and evaluation of the human fall detection system

    NASA Astrophysics Data System (ADS)

    Alzoubi, Hadeel; Ramzan, Naeem; Shahriar, Hasan; Alzubi, Raid; Gibson, Ryan; Amira, Abbes

    2016-10-01

    Falls are the most critical health problem for elderly people, which are often, cause significant injuries. To tackle a serious risk that made by the fall, we develop an automatic wearable fall detection system utilizing two devices (mobile phone and wireless sensor) based on three axes accelerometer signals. The goal of this study is to find an effective machine learning method that distinguish falls from activities of daily living (ADL) using only a single triaxial accelerometer. In addition, comparing the performance results for wearable sensor and mobile device data .The proposed model detects the fall by using seven different classifiers and the significant performance is demonstrated using accuracy, recall, precision and F-measure. Our model obtained accuracy over 99% on wearable device data and over 97% on mobile phone data.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bueno, G.; Ruiz, M.; Sanchez, S

    Breast cancer continues to be an important health problem between women population. Early detection is the only way to improve breast cancer prognosis and significantly reduce women mortality. It is by using CAD systems that radiologist can improve their ability to detect, and classify lesions in mammograms. In this study the usefulness of using B-spline based on a gradient scheme and compared to wavelet and adaptative filtering has been investigated for calcification lesion detection and as part of CAD systems. The technique has been applied to different density tissues. A qualitative validation shows the success of the method.

  1. Enolization of acetone in superheated water detected via radical formation.

    PubMed

    Ghandi, Khashayar; Addison-Jones, Brenda; Brodovitch, Jean-Claude; McCollum, Brett M; McKenzie, Iain; Percival, Paul W

    2003-08-13

    Muoniated free radicals have been detected in muon-irradiated aqueous solutions of acetone at high temperatures and pressures. At temperatures below 250 degrees C, the radical product is consistent with muonium addition to the keto form of acetone. However, at higher temperatures, a different radical was detected, which is attributed to muonium addition to the enol form. Muon hyperfine coupling constants have been determined for both radicals over a wide range of temperatures, significantly extending the range of conditions under which these radicals and the keto-enol equilibrium have been studied.

  2. The Teleost Octavolateralis System: Structure and Function

    NASA Technical Reports Server (NTRS)

    Popper, Arthur N.

    1996-01-01

    This paper considers the detection of vibrational signals (including sound) by the two components of the octavolateralis system, the ear and mechanosensory lateral line. Together, these systems provide fishes with a good deal of information about their surrounding environment, and enable fishes to detect both predators and prey. While the mechanisms by which fishes and zooplankton produce and detect signals may differ, it is clear that the physical principles underlying the signals themselves are identical, no matter whether we are dealing with fish or zooplankton. Thus, an understanding of signal production and detection mechanisms by fishes can be of significant help in understanding how similar systems would function in zooplankton.

  3. Wedge-shaped microfluidic chip for circulating tumor cells isolation and its clinical significance in gastric cancer.

    PubMed

    Yang, Chaogang; Zhang, Nangang; Wang, Shuyi; Shi, Dongdong; Zhang, Chunxiao; Liu, Kan; Xiong, Bin

    2018-05-23

    Circulating tumor cells (CTCs) have great potential in both basic research and clinical application for the managements of cancer. However, the complicated fabrication processes and expensive materials of the existing CTCs isolation devices, to a large extent, limit their clinical translation and CTCs' clinical value. Therefore, it remains to be urgently needed to develop a new platform for achieving CTCs detection with low-cost, mass-producible but high performance. In the present study, we introduced a novel wedge-shaped microfluidic chip (named CTC-ΔChip) fabricated by two pieces of glass through wet etching and thermal bonding technique for CTCs isolation, which achieved CTCs enrichment by different size without cell surface expression markers and CTCs identification with three-color immunocytochemistry method (CK+/CD45-/Nucleus+). We validated the feasibility of CTC-ΔChip for detecting CTCs from different types of solid tumor. Furthermore, we applied the newly-developed platform to investigate the clinical significance of CTCs in gastric cancer (GC). Based on "label-free" characteristic, the capture efficiency of CTC-ΔChip can be as high as 93.7 ± 3.2% in DMEM and 91.0 ± 3.0% in whole blood sample under optimized conditions. Clinically, CTC-ΔChip exhibited the feasibility of detecting CTCs from different types of solid tumor, and it identified 7.30 ± 7.29 CTCs from 2 mL peripheral blood with a positive rate of 75% (30/40) in GC patients. Interestingly, we found that GC CTCs count was significantly correlated with multiple systemic inflammation indexes, including the lymphocyte count, platelet count, the level of neutrophil to lymphocyte ratio and platelet to lymphocyte ratio. In addition, we also found that both the positivity rate and CTCs count were significantly associated with multiple clinicopathology parameters. Our novel CTC-ΔChip shows high performance for detecting CTCs from less volume of blood samples of cancer patients and important clinical significance in GC. Owing to the advantages of low-cost and mass-producible, CTC-ΔChip holds great potential of clinical application for cancer therapeutic guidance and prognostic monitoring in the future.

  4. Critical Analysis of an e-Learning and Interactive Teaching Module with Respect to the Interpretation of Emergency Computed Tomography of the Brain.

    PubMed

    Groth, Michael; Barthe, Käthe Greta; Riemer, Martin; Ernst, Marielle; Herrmann, Jochen; Fiehler, Jens; Buhk, Jan-Hendrik

    2018-04-01

     To compare the learning benefit of three different teaching strategies on the interpretation of emergency cerebral computed tomography (CT) pathologies by medical students.  Three groups of students with different types of teaching (e-learning, interactive teaching, and standard curricular education in neuroradiology) were tested with respect to the detection of seven CT pathologies. The test results of each group were compared for each CT pathology using the chi-square test. A p-value ≤ 0.05 was considered to be significant.  Opposed to the results of the comparison group (curricular education), the e-learning group and interactive teaching tutorial group both showed a significantly better performance in detecting hyperdense middle cerebral artery sign (p = 0.001 and p < 0.0001) as well as subarachnoid hemorrhage (p = 0.03 and p = 0.001) on CT. Moreover, an increase in performance for the detection of subdural hematoma and skull fracture could be observed for both the interactive teaching group and the e-learning group, with statistical significance in the latter (p = 0.03 and p < 0.0001, respectively). No statistically significant differences were found for the detection of intracranial and epidural hemorrhage, as well as midline shift, among the groups studied.  Our study demonstrates potential learning benefits for both the interactive teaching tutorial and e-learning module group with respect to reading CT scans with slightly different advantages. Thus, the introduction of new learning methods in radiological education might be reasonable at an undergraduate stage but requires learning content-based considerations.   · E-learning can offer benefits regarding the reading of cerebral CT scans by students. · Interactive tutorial can offer benefits regarding the reading of cerebral CT scans by students. · E-learning and interactive tutorial feature different strengths for student learning in radiology. · Application of interactive teaching methods in radiology requires learning content-based considerations. · Groth M, Barthe KG, Riemer M et al. Critical Analysis of an e-Learning and Interactive Teaching Module with Respect to the Interpretation of Emergency Computed Tomography of the Brain. Fortschr Röntgenstr 2017; 190: 334 - 340. © Georg Thieme Verlag KG Stuttgart · New York.

  5. [Detection of intraorbital foreign material using MDCT].

    PubMed

    Hoffstetter, P; Friedrich, C; Framme, C; Hoffstetter, M; Zorger, N; Stierstorfer, K; Ross, C; Uller, W; Müller-Wille, R; Rennert, J; Jung, E M; Schreyer, A G

    2011-06-01

    To judge the possibilities of detection of orbital foreign bodies in multidetector CT (MDCT) with a focus on glass slivers. Experimental systematic measuring of Hounsfield Units (HU) of 20 different materials, containing 16 different types of glass with 4 different types of ophthalmic lenses among them. The measurements were performed using a standardized protocol with an orbita phantom being scanned with 16-slice MDCT. Using the resulting density values, the smallest detectable volume was calculated. Using this data we produced slivers of 5 different glass types in the sub-millimeter range and calculated their volume. Those micro-slivers underwent another CT scan using the same protocol as mentioned above to experimentally discern and confirm the detection limit for micro-slivers made of different materials. Glass has comparatively high density values of at least 2000 HU. The density of glasses with strong refraction is significantly higher and reaches up to 12 400 HU. We calculated a minimum detectable volume of 0.07 mm (3) for glass with a density of 2000 HU. Only glass slivers with a density higher than 8300 HU were experimentally detectable in the sub-millimeter range up to a volume as small as 0.01 mm (3). Less dense glass slivers could not be seen, even though their volume was above the theoretically calculated threshold for detection. Due to its high density of at least 2000 HU, glass is usually easily recognizable as an orbital foreign body. The detection threshold depends on the object's density and size and can be as low as 0.01 mm (3) in the case of glass with strong refraction and thus high density. The detection of glass as an orbital foreign body seems to be secure for slivers with a volume of at least 0.2 mm (3) for all types of glass. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Developmental differences in auditory detection and localization of approaching vehicles.

    PubMed

    Barton, Benjamin K; Lew, Roger; Kovesdi, Casey; Cottrell, Nicholas D; Ulrich, Thomas

    2013-04-01

    Pedestrian safety is a significant problem in the United States, with thousands being injured each year. Multiple risk factors exist, but one poorly understood factor is pedestrians' ability to attend to vehicles using auditory cues. Auditory information in the pedestrian setting is increasing in importance with the growing number of quieter hybrid and all-electric vehicles on America's roadways that do not emit sound cues pedestrians expect from an approaching vehicle. Our study explored developmental differences in pedestrians' detection and localization of approaching vehicles. Fifty children ages 6-9 years, and 35 adults participated. Participants' performance varied significantly by age, and with increasing speed and direction of the vehicle's approach. Results underscore the importance of understanding children's and adults' use of auditory cues for pedestrian safety and highlight the need for further research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Physical security and cyber security issues and human error prevention for 3D printed objects: detecting the use of an incorrect printing material

    NASA Astrophysics Data System (ADS)

    Straub, Jeremy

    2017-06-01

    A wide variety of characteristics of 3D printed objects have been linked to impaired structural integrity and use-efficacy. The printing material can also have a significant impact on the quality, utility and safety characteristics of a 3D printed object. Material issues can be created by vendor issues, physical security issues and human error. This paper presents and evaluates a system that can be used to detect incorrect material use in a 3D printer, using visible light imaging. Specifically, it assesses the ability to ascertain the difference between materials of different color and different types of material with similar coloration.

  8. Molecular Epidemiology of Rhinovirus Detections in Young Children

    PubMed Central

    Howard, Leigh M.; Johnson, Monika; Gil, Ana I.; Griffin, Marie R.; Edwards, Kathryn M.; Lanata, Claudio F.; Williams, John V.; Grijalva, Carlos G.

    2016-01-01

    Background. Human rhinoviruses (HRVs) are frequently detected in children with acute respiratory illnesses (ARIs) but also in asymptomatic children. We compared features of ARI with HRV species (A, B, C) and determined genotypes associated with repeated HRV detections within individuals. Methods. We used clinical data and respiratory samples obtained from children <3 years old during weekly active household-based surveillance. A random subset of samples in which HRV was detected from individuals during both ARI and an asymptomatic period within 120 days of the ARI were genotyped. Features of ARI were compared among HRV species. Concordance of genotype among repeated HRV detections within individuals was assessed. Results. Among 207 ARI samples sequenced, HRV-A, HRV-B, and HRV-C were detected in 104 (50%), 20 (10%), and 83 (40%), respectively. Presence of fever, decreased appetite, and malaise were significantly higher in children with HRV-B. When codetections with other viruses were excluded (n = 155), these trends persisted, but some did not reach statistical significance. When 58 paired sequential HRV detections during asymptomatic and ARI episodes were sequenced, only 9 (16%) were identical genotypes of HRV. Conclusions. Clinical features may differ among HRV species. Repeated HRV detections in young children frequently represented acquisition of new HRV strains. PMID:26900577

  9. Colorectal and interval cancers of the Colorectal Cancer Screening Program in the Basque Country (Spain)

    PubMed Central

    Portillo, Isabel; Arana-Arri, Eunate; Idigoras, Isabel; Bilbao, Isabel; Martínez-Indart, Lorea; Bujanda, Luis; Gutierrez-Ibarluzea, Iñaki

    2017-01-01

    AIM To assess proportions, related conditions and survival of interval cancer (IC). METHODS The programme has a linkage with different clinical databases and cancer registers to allow suitable evaluation. This evaluation involves the detection of ICs after a negative faecal inmunochemical test (FIT), interval cancer FIT (IC-FIT) prior to a subsequent invitation, and the detection of ICs after a positive FIT and confirmatory diagnosis without colorectal cancer (CRC) detected and before the following recommended colonoscopy, IC-colonoscopy. We conducted a retrospective observational study analyzing from January 2009 to December 2015 1193602 invited people onto the Programme (participation rate of 68.6%). RESULTS Two thousand five hundred and eighteen cancers were diagnosed through the programme, 18 cases of IC-colonoscopy were found before the recommended follow-up (43542 colonoscopies performed) and 186 IC-FIT were identified before the following invitation of the 769200 negative FITs. There was no statistically significant relation between the predictor variables of ICs with sex, age and deprivation index, but there was relation between location and stage. Additionally, it was observed that there was less risk when the location was distal rather than proximal (OR = 0.28, 95%CI: 0.20-0.40, P < 0.0001), with no statistical significance when the location was in the rectum as opposed to proximal. When comparing the screen-detected cancers (SCs) with ICs, significant differences in survival were found (P < 0.001); being the 5-years survival for SCs 91.6% and IC-FIT 77.8%. CONCLUSION These findings in a Population Based CRC Screening Programme indicate the need of population-based studies that continue analyzing related factors to improve their detection and reducing harm. PMID:28487610

  10. Cross-correlating Planck tSZ with RCSLenS weak lensing: implications for cosmology and AGN feedback

    NASA Astrophysics Data System (ADS)

    Hojjati, Alireza; Tröster, Tilman; Harnois-Déraps, Joachim; McCarthy, Ian G.; van Waerbeke, Ludovic; Choi, Ami; Erben, Thomas; Heymans, Catherine; Hildebrandt, Hendrik; Hinshaw, Gary; Ma, Yin-Zhe; Miller, Lance; Viola, Massimo; Tanimura, Hideki

    2017-10-01

    We present measurements of the spatial mapping between (hot) baryons and the total matter in the Universe, via the cross-correlation between the thermal Sunyaev-Zeldovich (tSZ) map from Planck and the weak gravitational lensing maps from the Red Cluster Sequence Lensing Survey (RCSLenS). The cross-correlations are performed on the map level where all the sources (including diffuse intergalactic gas) contribute to the signal. We consider two configuration-space correlation function estimators, ξy-κ and ξ ^ {y-γ t}, and a Fourier-space estimator, C_{ℓ}^{y-κ}, in our analysis. We detect a significant correlation out to 3° of angular separation on the sky. Based on statistical noise only, we can report 13σ and 17σ detections of the cross-correlation using the configuration-space y-κ and y-γt estimators, respectively. Including a heuristic estimate of the sampling variance yields a detection significance of 7σ and 8σ, respectively. A similar level of detection is obtained from the Fourier-space estimator, C_{ℓ}^{y-κ}. As each estimator probes different dynamical ranges, their combination improves the significance of the detection. We compare our measurements with predictions from the cosmo-OverWhelmingly Large Simulations suite of cosmological hydrodynamical simulations, where different galactic feedback models are implemented. We find that a model with considerable active galactic nuclei (AGN) feedback that removes large quantities of hot gas from galaxy groups and Wilkinson Microwave Anisotropy Probe 7-yr best-fitting cosmological parameters provides the best match to the measurements. All baryonic models in the context of a Planck cosmology overpredict the observed signal. Similar cosmological conclusions are drawn when we employ a halo model with the observed 'universal' pressure profile.

  11. Effectiveness of teaching International Caries Detection and Assessment System II and its e-learning program to freshman dental students on occlusal caries detection

    PubMed Central

    El-Damanhoury, Hatem M.; Fakhruddin, Kausar Sadia; Awad, Manal A.

    2014-01-01

    Objective: To assess the feasibility of teaching International Caries Detection and Assessment System (ICDAS) II and its e-learning program as tools for occlusal caries detection to freshmen dental students in comparison to dental graduates with 2 years of experience. Materials and Methods: Eighty-four freshmen and 32 dental graduates examined occlusal surfaces of molars/premolars (n = 72) after a lecture and a hands-on workshop. The same procedure was repeated after 1 month following the training with ICDAS II e-learning program. Validation of ICDAS II codes was done histologically. Intra- and inter-examiner reproducibility of ICDAS II severity scores were assessed before and after e-learning using (Fleiss's kappa). Results: The kappa values showed inter-examiner reproducibility ranged from 0.53 (ICDAS II code cut off ≥ 1) to 0.70 (ICDAS II code cut off ≥ 3) by undergraduates and 0.69 (ICDAS II code cut off ≥ 1) to 0.95 (ICDAS II code cut off ≥ 3) by graduates. The inter-examiner reproducibility ranged from 0.64 (ICDAS II code cut off ≥ 1) to 0.89 (ICDAS II code cut off ≥ 3). No statistically significant difference was found between both groups in intra-examiner agreements for assessing ICDAS II codes. A high statistically significant difference (P ≤ 0.01) in correct identification of codes 1, 2, and 4 from before to after e-learning were observed in both groups. The bias indices for the undergraduate group were higher than those of the graduate group. Conclusions: Early exposure of students to ICDAS II is a valuable method of teaching caries detection and its e-learning program significantly improves their caries diagnostic skills. PMID:25512730

  12. 18F-choline PET/MRI in suspected recurrence of prostate carcinoma.

    PubMed

    Riola-Parada, C; Carreras-Delgado, J L; Pérez-Dueñas, V; Garcerant-Tafur, M; García-Cañamaque, L

    2018-05-21

    To evaluate the usefulness of simultaneous 18 F-choline PET/MRI in the suspicion of prostate cancer recurrence and to relate 18 F-choline PET/MRI detection rate with analytical and pathological variables. 27 patients with prostate cancer who received local therapy as primary treatment underwent a 18 F-choline PET/MRI due to suspicion of recurrence (persistently rising serum PSA level). 18 F-choline PET/MRI findings were validated by anatomopathological analysis, other imaging tests or by biochemical response to oncological treatment. 18 F-choline PET/MRI detected disease in 15 of 27 patients (detection rate 55.56%). 4 (15%) presented exclusively local recurrence, 5 (18%) lymph node metastases and 7 (26%) bone metastases. Mean PSA (PSA med ) at study time was 2.94ng/mL (range 0.18-10ng/mL). PSA med in patients with positive PET/MRI was 3.70ng/mL (range 0.24-10ng/mL), higher than in patients with negative PET/MRI, PSA med 1.97ng/mL (range 0.18-4.38ng/mL), although without statistically significant differences. Gleason score at diagnosis in patients with a positive study was 7.33 (range 6-9) and in patients with a negative study was 7 (range 6-9), without statistically significant differences. 18 F-choline PET/MRI detection rate was considerable despite the relatively low PSA values in our sample. The influence of Gleason score and PSA level on 18 F-choline PET/MRI detection rate was not statistically significant. Copyright © 2018 Sociedad Española de Medicina Nuclear e Imagen Molecular. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Development of an auditory situation awareness test battery for advanced hearing protectors and TCAPS: detection subtest of DRILCOM (detection-recognition/identification-localization-communication).

    PubMed

    Lee, Kichol; Casali, John G

    2017-01-01

    To design a test battery and conduct a proof-of-concept experiment of a test method that can be used to measure the detection performance afforded by military advanced hearing protection devices (HPDs) and tactical communication and protective systems (TCAPS). The detection test was conducted with each of the four loudspeakers located at front, right, rear and left of the participant. Participants wore 2 in-ear-type TCAPS, 1 earmuff-type TCAPS, a passive Combat Arms Earplug in its "open" or pass-through setting and an EB-15LE™ electronic earplug. Devices with electronic gain systems were tested under two gain settings: "unity" and "max". Testing without any device (open ear) was conducted as a control. Ten participants with audiometric requirements of 25 dBHL or better at 500, 1000, 2000, 4000, 8000 Hz in both ears. Detection task performance varied with different signals and speaker locations. The test identified performance differences among certain TCAPS and protectors, and the open ear. A computer-controlled detection subtest of the Detection-Recognition/Identification-Localisation-Communication (DRILCOM) test battery was designed and implemented. Tested in a proof-of-concept experiment, it showed statistically-significant sensitivity to device differences in detection effects with the small sample of participants (10). This result has important implications for selection and deployment of TCAPS and HPDs on soldiers and workers in dynamic situations.

  14. Seroprevalence of HCV among Cairo University students in Egypt.

    PubMed

    Esmat, Gamal; Raziky, Maissa El; Nabeel, Mohammed M; Maher, Rabab; Zakaria, Zeinab

    2016-08-01

    Hepatitis C virus (HCV) is highly prevalent in Egypt. This work aimed at determining the seroprevalence of HCV among Cairo University students. The present study included 3,000 students from Cairo University, Egypt. Blood sample was obtained from each participant to be tested for HCV seromarker. HCV RNA detection by polymerase chain reaction (PCR) was carried out for those with positive anti-HCV. Overall prevalence rate of HCV antibody (anti-HCV) was 4.6%. It showed that the prevalence was relatively higher among females (86/1660; 5.2%) while males (51/1340; 3.8%) with no significant difference. PCR for HCV RNA was detected in 31.4% of the HCV antibody positive subjects (43/137). Which showed statistical significant difference between males (29/51) and females (14/86) at P = 0.001. Despite the prevalence rate reported in the present study was similar to anti-HCV prevalence among persons in the same age group, confirmed that HCV infection is detected among Cairo University students. J. Med. Virol. 88:1384-1387, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Topoclimatological and snowhydrological survey of Switzerland

    NASA Technical Reports Server (NTRS)

    Winiger, M. (Principal Investigator)

    1979-01-01

    The author has identified the following significant results. The chosen time of overflight of HCMM seems to be ideal for the study of basic climatological events. Nocturnal temperature inversion zones are easily detectable and their dependency on the relief is clearly seen. Especially the alpine valleys show a very differentiated pattern of cold lakes, separated by warmer zones as a consequence of rock and forrest barriers or changes in the valley profile. Wet areas are usually colder than dry parts under comparable topographic conditions. Even very small topographic obstacles are able to block up the flow of cold air masses (or ground water flow). Urban areas are clearly detectable. Differences to the surface temperatures of surrounding rural land are much more significant during day-time (mainly during the summer months). Fog layers are clearly defined in the visible channel (day-time), but much more difficult to identify in the IR (mainly during the night). There is not a fundamental difference to NOAA-analysis of cloud systems. The most important advantage is the better detectability of convective cloud systems (small cumulus clouds).

  16. Impact of the 4G/5G polymorphism in the plasminogen activator inhibitor-1 gene on primary nephrotic syndrome.

    PubMed

    Luo, Yuezhong; Wang, Chao; Tu, Haitao

    2014-03-01

    The aim of the present study was to investigate whether the four guanosines (4G)/five guanosines (5G) polymorphism in the gene coding for plasminogen activator inhibitor-1 (PAI-1) affects the clinical features of primary nephrotic syndrome (PNS). A cohort of 200 biopsy-diagnosed PNS patients was studied, with 40 healthy subjects as controls. The PAI-1 gene polymorphism was detected by polymerase chain reaction and DNA sequencing. Associations between the PAI-1 4G/5G polymorphism and clinical features and pathological types of PNS were analyzed. The results indicated that the PAI-1 genotype distribution is significantly different between patients with PNS and healthy controls, with significantly higher numbers of the 4G/4G genotype and lower numbers of the 5G5G genotype detected in PNS patients compared to controls (both P<0.05). The frequency of the 4G allele was also significantly higher in PNS patients compared to healthy controls (P<0.01). Among the different pathological types of PNS, IgA nephropathy (IgAN) and membranous nephropathy (MN) were associated with significantly increased frequencies of the 4G/4G and 4G/5G genotypes, as well as of the 4G allele. The increased 4G frequency was also detected in patients with minimal change disease (MCD). Significantly increased international normalized ratio (INR) and prolonged activated partial thromboplastin time (APTT) were observed in 4G/4G compared to 5G/5G PNS subjects. The response to steroids was not significantly different among the three genotypes. In conclusion, the 4G allele of the PAI-1 gene appears to be associated with PNS, especially in MN and IgAN patients. These findings suggest that specific targeting may be required for the treatment of PNS patients with the 4G/4G genotype.

  17. Serum aluminium levels of workers in the bauxite mines.

    PubMed

    de Kom, J F; Dissels, H M; van der Voet, G B; de Wolff, F A

    1997-01-01

    Aluminium is produced from the mineral bauxite. Occupational exposure is reported during the industrial processing of aluminium and is associated with pulmonary and neurotoxicity. However, data on exposure and toxicity of workers in the open bauxite mining industry do not exist. Therefore, a study was performed to explore aluminium exposure in employees involved in this bauxite mining process in a Surinam mine. A group of workers occupationally exposed to aluminium in an open bauxite mine were compared with a group of nonexposed wood processors. Serum aluminium was analyzed using atomic absorption spectrometry Data from the clinical chemistry of the blood and a questionnaire were used to explore determinants for aluminium exposure. No significant difference between serum aluminium in the exposed (4.4 +/- 2.0 micrograms/L, n = 27) and control group (5.1 +/- 1.5 micrograms/L, n = 27) was detected. For the serum concentration of the clinical chemical variables (calcium, citrate, and creatinine), a statistically significant difference was computed (p < or = 0.02) between the exposed and control group. All levels were slightly higher in the exposed group; no statistically significant correlations with serum aluminium were found. In this study, serum aluminium values were in the normal range, no significant difference between the groups could be detected despite long-term occupational exposure.

  18. HPV detection rate in saliva may depend on the immune system efficiency.

    PubMed

    Adamopoulou, Maria; Vairaktaris, Eleftherios; Panis, Vassilis; Nkenke, Emeka; Neukam, Friedreich W; Yapijakis, Christos

    2008-01-01

    Human papilloma virus (HPV) has been established as a major etiological factor of anogenital cancer. In addition, HPV has also been implicated in oral carcinogenesis but its detection rates appear to be highly variable, depending on the patient population tested, the molecular methodology used, as well as the type of oral specimen investigated. For example, saliva is an oral fluid that may play a role in HPV transmission, although the detection rates of the virus are lower than tissue. Recent evidence has indicated that HPV-related pathology is increased in the oral cavity of human immunodeficiency virus (HIV)-positive individuals. In order to investigate whether the presence of different HPV types in saliva depends on immune system efficiency, oral fluid samples of patients with oral cancer and without any known immune deficiency were compared with those of HIV-positive individuals. Saliva samples were collected from 68 patients with oral squamous cell carcinoma and 34 HIV seropositive individuals. HPV DNA sequences were detected by L1 concensus polymerase chain reaction (PCR), followed by restriction fragment length polymorphism (RFLP) analysis and DNA sequencing for HPV typing. HPV DNA was detected in 7/68 (10.3%) of the oral cancer patients and in 12/34 (35.3%) of the HIV-positive individuals, a highly significant difference (p = 0.006; odds ratio 4.753; 95% confidence interval 1.698-13.271). Among HPV-positive samples, the prevalence of HPV types associated with high oncogenic risk was similar in oral cancer and HIV-positive cases (71.4% and 66.7%, respectively). In both groups, the most common HPV type was high-risk 16 (50% and 42.8%, respectively). Although a similar pattern of HPV high-risk types was detected in oral cancer and HIV-positive cases, the quantitative detection of HPV in saliva significantly depended on immune system efficiency. Furthermore, the significantly increased detection rates of HPV in saliva of HIV-positive individuals may be associated with high risk for development of HPV-related oral lesions, including malignancy.

  19. The Impact of a City-Level Minimum-Wage Policy on Supermarket Food Prices in Seattle-King County

    PubMed Central

    Tang, Wesley; Aggarwal, Anju; Vigdor, Jacob; Drewnowski, Adam

    2017-01-01

    Background: Many states and localities throughout the U.S. have adopted higher minimum wages. Higher labor costs among low-wage food system workers could result in higher food prices. Methods: Using a market basket of 106 foods, food prices were collected at affected chain supermarket stores in Seattle and same-chain unaffected stores in King County (n = 12 total, six per location). Prices were collected at 1 month pre- (March 2015) and 1-month post-policy enactment (May 2015), then again 1-year post-policy enactment (May 2016). Unpaired t-tests were used to detect price differences by location at fixed time while paired t-tests were used to detect price difference across time with fixed store chain. A multi-level, linear differences-in-differences model, was used to detect the changes in the average market basket item food prices over time across regions, overall and by food group. Results: There were no significant differences in overall market basket or item-level costs at one-month (−$0.01, SE = 0.05, p = 0.884) or one-year post-policy enactment (−$0.02, SE = 0.08, p = 0.772). No significant increases were observed by food group. Conclusions: There is no evidence of change in supermarket food prices by market basket or increase in prices by food group in response to the implementation of Seattle’s minimum wage ordinance. PMID:28891937

  20. Short cavity DFB fiber laser based vector hydrophone for low frequency signal detection

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaolei; Zhang, Faxiang; Jiang, Shaodong; Min, Li; Li, Ming; Peng, Gangding; Ni, Jiasheng; Wang, Chang

    2017-12-01

    A short cavity distributed feedback (DFB) fiber laser is used for low frequency acoustic signal detection. Three DFB fiber lasers with different central wavelengths are chained together to make three-element vector hydrophone with proper sensitivity enhancement design, which has extensive and significant applications to underwater acoustic monitoring for the national defense, oil, gas exploration, and so on. By wavelength-phase demodulation, the lasing wavelength changes under different frequency signals can be interpreted, and the sensitivity is tested about 33 dB re pm/g. The frequency response range is rather flat from 5 Hz to 300 Hz.

  1. A novel method for detection of apoptosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zagariya, Alexander M., E-mail: zagariya@uic.edu

    2012-04-15

    There are two different Angiotensin II (ANG II) peptides in nature: Human type (ANG II) and Bovine type (ANG II*). These eight amino acid peptides differ only at position 5 where Valine is replaced by Isoleucine in the Bovine type. They are present in all species studied so far. These amino acids are different by only one atom of carbon. This difference is so small, that it will allow any of ANG II, Bovine or Human antibodies to interact with all species and create a universal method for apoptosis detection. ANG II concentrations are found at substantially higher levels inmore » apoptotic, compared to non-apoptotic, tissues. ANG II accumulation can lead to DNA damage, mutations, carcinogenesis and cell death. We demonstrate that Bovine antiserum can be used for universal detection of apoptosis. In 2010, the worldwide market for apoptosis detection reached the $20 billion mark and significantly increases each year. Most commercially available methods are related to Annexin V and TUNNEL. Our new method based on ANG II is more widely known to physicians and scientists compared to previously used methods. Our approach offers a novel alternative for assessing apoptosis activity with enhanced sensitivity, at a lower cost and ease of use.« less

  2. Detection of Natural Toxoplasma gondii Infection in Chicken in Thika Region of Kenya Using Nested Polymerase Chain Reaction

    PubMed Central

    Karanja, Simon Muturi; Ngotho, Maina; Kamau, David Muchina; Njuguna, Adele Nyambura

    2016-01-01

    The detection of Toxoplasma gondii in free-range chickens is a good indicator of possible risk to human beings. The aim of this study was to investigate the occurrence of T. gondii in free-range chicken using polymerase chain reaction (PCR). Brain samples from 105 free-range chickens from three administrative areas in Thika region, Kenya, were collected, DNA-extracted, and analyzed using PCR to detect presence of T. gondii. The overall prevalence of T. gondii in all the three areas was 79.0% (95% CI: 70.0–86.4%) and the prevalence across the three areas was not significantly different (P = 0.5088; χ 2 = 1.354). Female chickens had higher (79.4%) prevalence than males (78.6%), although the difference was not significant (P = 0.922, χ 2 = 0.01). However, chickens that were more than 2 years old had significantly (P = 0.003; χ 2 = 11.87) higher prevalence compared to younger ones. The study indicates that there was a high occurrence of T. gondii infection in free-range chickens from Thika region and that the infection rate is age dependent. Further studies should be carried out to determine the possible role of roaming chickens in the epidemiology of the disease among humans in the area. PMID:27981052

  3. Detection of Natural Toxoplasma gondii Infection in Chicken in Thika Region of Kenya Using Nested Polymerase Chain Reaction.

    PubMed

    Mose, John Mokua; Kagira, John Maina; Karanja, Simon Muturi; Ngotho, Maina; Kamau, David Muchina; Njuguna, Adele Nyambura; Maina, Naomi Wangari

    2016-01-01

    The detection of Toxoplasma gondii in free-range chickens is a good indicator of possible risk to human beings. The aim of this study was to investigate the occurrence of T. gondii in free-range chicken using polymerase chain reaction (PCR). Brain samples from 105 free-range chickens from three administrative areas in Thika region, Kenya, were collected, DNA-extracted, and analyzed using PCR to detect presence of T. gondii . The overall prevalence of T. gondii in all the three areas was 79.0% (95% CI: 70.0-86.4%) and the prevalence across the three areas was not significantly different ( P = 0.5088; χ 2 = 1.354). Female chickens had higher (79.4%) prevalence than males (78.6%), although the difference was not significant ( P = 0.922, χ 2 = 0.01). However, chickens that were more than 2 years old had significantly ( P = 0.003; χ 2 = 11.87) higher prevalence compared to younger ones. The study indicates that there was a high occurrence of T. gondii infection in free-range chickens from Thika region and that the infection rate is age dependent. Further studies should be carried out to determine the possible role of roaming chickens in the epidemiology of the disease among humans in the area.

  4. Comparison of human observer and algorithmic target detection in nonurban forward-looking infrared imagery

    NASA Astrophysics Data System (ADS)

    Weber, Bruce A.

    2005-07-01

    We have performed an experiment that compares the performance of human observers with that of a robust algorithm for the detection of targets in difficult, nonurban forward-looking infrared imagery. Our purpose was to benchmark the comparison and document performance differences for future algorithm improvement. The scale-insensitive detection algorithm, used as a benchmark by the Night Vision Electronic Sensors Directorate for algorithm evaluation, employed a combination of contrastlike features to locate targets. Detection receiver operating characteristic curves and observer-confidence analyses were used to compare human and algorithmic responses and to gain insight into differences. The test database contained ground targets, in natural clutter, whose detectability, as judged by human observers, ranged from easy to very difficult. In general, as compared with human observers, the algorithm detected most of the same targets, but correlated confidence with correct detections poorly and produced many more false alarms at any useful level of performance. Though characterizing human performance was not the intent of this study, results suggest that previous observational experience was not a strong predictor of human performance, and that combining individual human observations by majority vote significantly reduced false-alarm rates.

  5. Imaging of underground karst water channels using an improved multichannel transient Rayleigh wave detecting method

    PubMed Central

    Zheng, Xuhui; Liu, Lei; Li, Gao; Zhou, Fubiao; Xu, Jiemin

    2018-01-01

    Geological and hydrogeological conditions in karst areas are complicated from the viewpoint of engineering. The construction of underground structures in these areas is often disturbed by the gushing of karst water, which may delay the construction schedule, result in economic losses, and even cause heavy casualties. In this paper, an innovative method of multichannel transient Rayleigh wave detecting is proposed by introducing the concept of arrival time difference phase between channels (TDP). Overcoming the restriction of the space-sampling law, the proposed method can extract the phase velocities of different frequency components from only two channels of transient Rayleigh wave recorded on two adjacent detecting points. This feature greatly improves the work efficiency and lateral resolution of transient Rayleigh wave detecting. The improved multichannel transient Rayleigh wave detecting method is applied to the detection of karst caves and fractures in rock mass of the foundation pit of Yan’an Road Station of Guiyang Metro. The imaging of the detecting results clearly reveals the distribution of karst water inflow channels, which provided significant guidance for water plugging and enabled good control over karst water gushing in the foundation pit. PMID:29883492

  6. Imaging of underground karst water channels using an improved multichannel transient Rayleigh wave detecting method.

    PubMed

    Zheng, Xuhui; Liu, Lei; Sun, Jinzhong; Li, Gao; Zhou, Fubiao; Xu, Jiemin

    2018-01-01

    Geological and hydrogeological conditions in karst areas are complicated from the viewpoint of engineering. The construction of underground structures in these areas is often disturbed by the gushing of karst water, which may delay the construction schedule, result in economic losses, and even cause heavy casualties. In this paper, an innovative method of multichannel transient Rayleigh wave detecting is proposed by introducing the concept of arrival time difference phase between channels (TDP). Overcoming the restriction of the space-sampling law, the proposed method can extract the phase velocities of different frequency components from only two channels of transient Rayleigh wave recorded on two adjacent detecting points. This feature greatly improves the work efficiency and lateral resolution of transient Rayleigh wave detecting. The improved multichannel transient Rayleigh wave detecting method is applied to the detection of karst caves and fractures in rock mass of the foundation pit of Yan'an Road Station of Guiyang Metro. The imaging of the detecting results clearly reveals the distribution of karst water inflow channels, which provided significant guidance for water plugging and enabled good control over karst water gushing in the foundation pit.

  7. The roles of garment design and scene complexity in the daytime conspicuity of high-visibility safety apparel.

    PubMed

    Sayer, James R; Buonarosa, Mary Lynn

    2008-01-01

    This study examines the effects of high-visibility garment design on daytime pedestrian conspicuity in work zones. Factors assessed were garment color, amount of background material, pedestrian arm motion, scene complexity, and driver age. The study was conducted in naturalistic conditions on public roads in real traffic. Drivers drove two passes on a 31-km route and indicated when they detected pedestrians outfitted in the fluorescent garments. The locations of the vehicle and the pedestrian were recorded. Detection distances between fluorescent yellow-green and fluorescent red-orange garments were not significantly different, nor were there any significant two-way interactions involving garment color. Pedestrians were detected at longer distances in lower complexity scenes. Arm motion significantly increased detection distances for pedestrians wearing a Class 2 vest, but had little added benefit on detection distances for pedestrians wearing a Class 2 jacket. Daytime detection distances for pedestrians wearing Class 2 or Class 3 garments are longest when the complexity of the surround is low. The more background information a driver has to search through, the longer it is likely to take the driver to locate a pedestrian--even when wearing a high-visibility garment. These findings will provide information to safety garment manufacturers about characteristics of high-visibility safety garments which make them effective for daytime use.

  8. The Relationship Between Spectral Modulation Detection and Speech Recognition: Adult Versus Pediatric Cochlear Implant Recipients

    PubMed Central

    Noble, Jack H.; Camarata, Stephen M.; Sunderhaus, Linsey W.; Dwyer, Robert T.; Dawant, Benoit M.; Dietrich, Mary S.; Labadie, Robert F.

    2018-01-01

    Adult cochlear implant (CI) recipients demonstrate a reliable relationship between spectral modulation detection and speech understanding. Prior studies documenting this relationship have focused on postlingually deafened adult CI recipients—leaving an open question regarding the relationship between spectral resolution and speech understanding for adults and children with prelingual onset of deafness. Here, we report CI performance on the measures of speech recognition and spectral modulation detection for 578 CI recipients including 477 postlingual adults, 65 prelingual adults, and 36 prelingual pediatric CI users. The results demonstrated a significant correlation between spectral modulation detection and various measures of speech understanding for 542 adult CI recipients. For 36 pediatric CI recipients, however, there was no significant correlation between spectral modulation detection and speech understanding in quiet or in noise nor was spectral modulation detection significantly correlated with listener age or age at implantation. These findings suggest that pediatric CI recipients might not depend upon spectral resolution for speech understanding in the same manner as adult CI recipients. It is possible that pediatric CI users are making use of different cues, such as those contained within the temporal envelope, to achieve high levels of speech understanding. Further investigation is warranted to investigate the relationship between spectral and temporal resolution and speech recognition to describe the underlying mechanisms driving peripheral auditory processing in pediatric CI users. PMID:29716437

  9. Odor Detection Thresholds in a Population of Older Adults

    PubMed Central

    Schubert, Carla R.; Fischer, Mary E.; Pinto, A. Alex; Klein, Barbara E.K.; Klein, Ronald; Cruickshanks, Karen J.

    2016-01-01

    OBJECTIVE To measure odor detection thresholds and associated nasal and behavioral factors in an older adult population. STUDY DESIGN Cross-sectional cohort study METHODS Odor detection thresholds were obtained using an automated olfactometer on 832 participants, aged 68–99 (mean age 77) years in the 21-year (2013–2016) follow-up visit of the Epidemiology of Hearing Loss Study. RESULTS The mean odor detection threshold (ODT) score was 8.2 (range: 1–13; standard deviation = 2.54), corresponding to a n-butanol concentration of slightly less than 0.03%. Older participants were significantly more likely to have lower (worse) ODT scores than younger participants (p<0.001). There were no significant differences in mean ODT scores between men and women. Older age was significantly associated with worse performance in multivariable regression models and exercising at least once a week was associated with a reduced odds of having a low (≤5) ODT score. Cognitive impairment was also associated with poor performance while a history of allergies or a deviated septum were associated with better performance. CONCLUSION Odor detection threshold scores were worse in older age groups but similar between men and women in this large population of older adults. Regular exercise was associated with better odor detection thresholds adding to the evidence that decline in olfactory function with age may be partly preventable. PMID:28000220

  10. Evaluation of 5 different labeled polymer immunohistochemical detection systems.

    PubMed

    Skaland, Ivar; Nordhus, Marit; Gudlaugsson, Einar; Klos, Jan; Kjellevold, Kjell H; Janssen, Emiel A M; Baak, Jan P A

    2010-01-01

    Immunohistochemical staining is important for diagnosis and therapeutic decision making but the results may vary when different detection systems are used. To analyze this, 5 different labeled polymer immunohistochemical detection systems, REAL EnVision, EnVision Flex, EnVision Flex+ (Dako, Glostrup, Denmark), NovoLink (Novocastra Laboratories Ltd, Newcastle Upon Tyne, UK) and UltraVision ONE (Thermo Fisher Scientific, Fremont, CA) were tested using 12 different, widely used mouse and rabbit primary antibodies, detecting nuclear, cytoplasmic, and membrane antigens. Serial sections of multitissue blocks containing 4% formaldehyde fixed paraffin embedded material were selected for their weak, moderate, and strong staining for each antibody. Specificity and sensitivity were evaluated by subjective scoring and digital image analysis. At optimal primary antibody dilution, digital image analysis showed that EnVision Flex+ was the most sensitive system (P < 0.005), with means of 8.3, 13.4, 20.2, and 41.8 gray scale values stronger staining than REAL EnVision, EnVision Flex, NovoLink, and UltraVision ONE, respectively. NovoLink was the second most sensitive system for mouse antibodies, but showed low sensitivity for rabbit antibodies. Due to low sensitivity, 2 cases with UltraVision ONE and 1 case with NovoLink stained false negatively. None of the detection systems showed any distinct false positivity, but UltraVision ONE and NovoLink consistently showed weak background staining both in negative controls and at optimal primary antibody dilution. We conclude that there are significant differences in sensitivity, specificity, costs, and total assay time in the immunohistochemical detection systems currently in use.

  11. Validation of the Argentine version of the Memory Binding Test (MBT) for Early Detection of Mild Cognitive Impairment

    PubMed Central

    Roman, Fabian; Iturry, Mónica; Rojas, Galeno; Barceló, Ernesto; Buschke, Herman; Allegri, Ricardo F.

    2016-01-01

    ABSTRACT Background: "Forgetfulness" is frequent in normal aging and characteristic of the early stages of dementia syndromes. The episodic memory test is central for detecting amnestic mild cognitive impairment (MCI). The Memory Binding Test (MBT) is a simple, easy and brief memory test to detect the early stage of episodic memory impairment. Objective: To validate the Argentine version of the MBT in a Latin American population and to estimate the diagnostic accuracy as a tool for early detection of MCI. Methods: 88 subjects (46 healthy controls and 42 patients with amnestic MCI) matched for age and educational level were evaluated by an extensive neuropsychological battery and the memory binding test. Results: A significantly better performance was detected in the control group; all MBT scales were predictive of MCI diagnosis (p<.01). The MBT showed high sensitivity (69%) and high specificity (88%), with a PPV of 93% and a NPV of 55% for associative paired recall. A statistically significant difference (c2=14,164, p<.001) was obtained when comparing the area under the curve (AUC) of the MBT (0.88) and the MMSE (0.70). Conclusion: The Argentine version of the MBT correlated significantly with the MMSE and the memory battery and is a useful tool in the detection of MCI. The operating characteristics of the MBT are well suited, surpassing other tests commonly used for detecting MCI. PMID:29213458

  12. The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

    PubMed Central

    Miri, Shimasadat; Mehralizadeh, Sandra; Sadri, Donya; Motamedi, Mahmood Reza Kalantar

    2015-01-01

    Purpose This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Results Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy. PMID:26389055

  13. Hepatocellular Carcinoma Screening Associated with Early Tumor Detection and Improved Survival Among Patients with Cirrhosis in the US.

    PubMed

    Singal, Amit G; Mittal, Sahil; Yerokun, Olutola A; Ahn, Chul; Marrero, Jorge A; Yopp, Adam C; Parikh, Neehar D; Scaglione, Steve J

    2017-09-01

    Professional societies recommend hepatocellular carcinoma screening in patients with cirrhosis, but high-quality data evaluating its effectiveness to improve early tumor detection and survival in "real world" clinical practice are needed. We aim to characterize the association between hepatocellular carcinoma screening and early tumor detection, curative treatment, and overall survival among patients with cirrhosis. We performed a retrospective cohort study of patients diagnosed with hepatocellular carcinoma between June 2012 and May 2013 at 4 health systems in the US. Patients were categorized in the screening group if hepatocellular carcinoma was detected by imaging performed for screening purposes. Generalized linear models and multivariate Cox regression with frailty adjustment were used to compare early detection, curative treatment, and survival between screen-detected and non-screen-detected patients. Among 374 hepatocellular carcinoma patients, 42% (n = 157) were detected by screening. Screen-detected patients had a significantly higher proportion of early tumors (Barcelona Clinic Liver Cancer stage A 63.1% vs 36.4%, P <.001) and were more likely to undergo curative treatment (31% vs 13%, P = .02). Hepatocellular carcinoma screening was significantly associated with improved survival in multivariate analysis (hazards ratio 0.41; 95% confidence interval, 0.26-0.65) after adjusting for patient demographics, Child-Pugh class, and performance status. Median survival of screen-detected patients was 14.6 months, compared with 6.0 months for non-screen-detected patients, with the difference remaining significant after adjusting for lead-time bias (hazards ratio 0.59, 95% confidence interval, 0.37-0.93). Hepatocellular carcinoma screening is associated with increased early tumor detection and improved survival; however, a minority of hepatocellular carcinoma patients are detected by screening. Interventions to increase screening use in patients with cirrhosis may help curb hepatocellular carcinoma mortality rates. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. VIRAL LOAD AND SHORT-TERM NATURAL HISTORY OF TYPE-SPECIFIC ONCOGENIC HUMAN PAPILLOMAVIRUS INFECTIONS IN A HIGH-RISK COHORT OF MID-ADULT WOMEN

    PubMed Central

    Winer, Rachel L.; Xi, Long Fu; Shen, Zhenping; Stern, Joshua E.; Newman, Laura; Feng, Qinghua; Hughes, James P.; Koutsky, Laura A.

    2013-01-01

    Oncogenic human papillomavirus (HPV) viral load may inform the origin of newly detected infections and characterize oncogenic HPV natural history in mid-adult women. From 2007–2011, we enrolled 521 25–65 year old female online daters and followed them triannually with mailed health and sexual behavior questionnaires and kits for self-sampling for PCR-based HPV DNA testing. Samples from oncogenic HPV positive women were selected for type-specific DNA load testing by real-time PCR with adjustment for cellularity. Linear or logistic regression models were used to evaluate relationships between viral levels, health and sexual behavior, and longitudinal oncogenic HPV detection. Type-specific viral levels were borderline significantly higher in oncogenic HPV infections that were prevalent versus newly detected (p=0.092), but levels in newly detected infections were higher than in infections re-detected after intercurrent negativity (p<.001). Recent sex partners were not significantly associated with viral levels. Compared to prevalent infections detected intermittently, the likelihood of persistent (OR=4.31,95%CI:2.20–8.45) or single-time (OR=1.32,95%CI:1.03–1.71) detection increased per 1-unit increase in baseline log10 viral load. Viral load differences between re-detected and newly detected infections suggest a portion of new detections were due to new acquisition, although report of recent new sex partners (a potential marker of new infection) was not predictive of viral load; oncogenic HPV infections in mid-adult women with new partners likely represent a mix of new acquisition and reactivation or intermittent detection of previous infection. Intermittent detection was characterized by low viral levels, suggesting that intermittent detection of persisting oncogenic HPV infection may be of limited clinical significance PMID:24136492

  15. [Clinical significance of HPV L1 capsid protein detection in cervical exfoliated cells in high-risk HPV positive women].

    PubMed

    Wang, Jiajian; Tian, Qifang; Zhang, Su; Lyu, Liping; Dong, Jie; Lyu, Weiguo

    2015-04-01

    To explore the clinical significance of human papillomavirus L1 capsid protein detection in cervical exfoliated cells in high-risk HPV positive women. From November 2012 to June 2013, 386 high-risk HPV positive (detected by hybrid capture II) cases were enrolled as eligible women from Huzhou Maternity & Child Care Hospital and Women's Hospital, School of Medicine, Zhejiang University. All eligible women underwent liquid-based cytology (ThinPrep) followed by colposcopy. Biopsies were taken if indicated. Cervical exfoliated cells were collected for HPV L1 capsid protein detection by immunocytochemistry. Expression of HPV L1 capsid protein in groups with different histological diagnosis were compared, and the role of HPV L1 capsid protein detection in cervical exfoliated cells in cervical lesions screening was accessed. Total 386 enrolled eligible women were finally diagnosed histologically as follwed: 162 normal cervix, 94 low-grade squamous intraepithelial lesion (LSIL), 128 high-grade squamous intraepithelial lesion (HSIL) and 2 squamous cervical cancer (SCC). The positive expression rate of HPV L1 in HSIL+ (HSIL or worse) group was significantly lower than that in LSIL- (LSIL or better) group (19.2% vs 66.4%, P=0.000). While identifying HSIL+ in HPV positive cases and compared with cytology, HPV L1 detection resulted in significant higher sensitivity (80.77% vs 50.77%, P=0.000) and negative predictive value (NPV; 87.18% vs 76.47%, P=0.004), significant lower specificity (66.41% vs 81.25%, P=0.000), and comparable positive predictive value (PPV; 54.97% vs 57.89%, P=0.619). To identify HSIL+ in HPV-positive/cytology-negative women, the sensitivity, specificity, PPV, and NPV of HPV L1 detection were 87.50%, 61.54%, 41.18%, and 94.12% respectively, while 80.00%, 86.36%, 80.00% and 86.36% respectively in HPV-positive/atypical squamous cell of undetermined significance (ASCUS) women. HPV L1 capsid detection in cervical exfoliated cells have a role in cervical lesions screening in high-risk HPV positive women, and may be a promising triage for high-risk HPV-positive/cytology-negative or ASCUS women.

  16. Exploring homogeneity of correlation structures of gene expression datasets within and between etiological disease categories.

    PubMed

    Jong, Victor L; Novianti, Putri W; Roes, Kit C B; Eijkemans, Marinus J C

    2014-12-01

    The literature shows that classifiers perform differently across datasets and that correlations within datasets affect the performance of classifiers. The question that arises is whether the correlation structure within datasets differ significantly across diseases. In this study, we evaluated the homogeneity of correlation structures within and between datasets of six etiological disease categories; inflammatory, immune, infectious, degenerative, hereditary and acute myeloid leukemia (AML). We also assessed the effect of filtering; detection call and variance filtering on correlation structures. We downloaded microarray datasets from ArrayExpress for experiments meeting predefined criteria and ended up with 12 datasets for non-cancerous diseases and six for AML. The datasets were preprocessed by a common procedure incorporating platform-specific recommendations and the two filtering methods mentioned above. Homogeneity of correlation matrices between and within datasets of etiological diseases was assessed using the Box's M statistic on permuted samples. We found that correlation structures significantly differ between datasets of the same and/or different etiological disease categories and that variance filtering eliminates more uncorrelated probesets than detection call filtering and thus renders the data highly correlated.

  17. MAVTgsa: An R Package for Gene Set (Enrichment) Analysis

    DOE PAGES

    Chien, Chih-Yi; Chang, Ching-Wei; Tsai, Chen-An; ...

    2014-01-01

    Gene semore » t analysis methods aim to determine whether an a priori defined set of genes shows statistically significant difference in expression on either categorical or continuous outcomes. Although many methods for gene set analysis have been proposed, a systematic analysis tool for identification of different types of gene set significance modules has not been developed previously. This work presents an R package, called MAVTgsa, which includes three different methods for integrated gene set enrichment analysis. (1) The one-sided OLS (ordinary least squares) test detects coordinated changes of genes in gene set in one direction, either up- or downregulation. (2) The two-sided MANOVA (multivariate analysis variance) detects changes both up- and downregulation for studying two or more experimental conditions. (3) A random forests-based procedure is to identify gene sets that can accurately predict samples from different experimental conditions or are associated with the continuous phenotypes. MAVTgsa computes the P values and FDR (false discovery rate) q -value for all gene sets in the study. Furthermore, MAVTgsa provides several visualization outputs to support and interpret the enrichment results. This package is available online.« less

  18. Multiplex PCR Assay for Identification of Six Different Staphylococcus spp. and Simultaneous Detection of Methicillin and Mupirocin Resistance

    PubMed Central

    Campos-Peña, E.; Martín-Nuñez, E.; Pulido-Reyes, G.; Martín-Padrón, J.; Caro-Carrillo, E.; Donate-Correa, J.; Lorenzo-Castrillejo, I.; Alcoba-Flórez, J.; Machín, F.

    2014-01-01

    We describe a new, efficient, sensitive, and fast single-tube multiple-PCR protocol for the identification of the most clinically significant Staphylococcus spp. and the simultaneous detection of the methicillin and mupirocin resistance loci. The protocol identifies at the species level isolates belonging to S. aureus, S. epidermidis, S. haemolyticus, S. hominis, S. lugdunensis, and S. saprophyticus. PMID:24829244

  19. MPLNET V3 Cloud and Planetary Boundary Layer Detection

    NASA Technical Reports Server (NTRS)

    Lewis, Jasper R.; Welton, Ellsworth J.; Campbell, James R.; Haftings, Phillip C.

    2016-01-01

    The NASA Micropulse Lidar Network Version 3 algorithms for planetary boundary layer and cloud detection are described and differences relative to the previous Version 2 algorithms are highlighted. A year of data from the Goddard Space Flight Center site in Greenbelt, MD consisting of diurnal and seasonal trends is used to demonstrate the results. Both the planetary boundary layer and cloud algorithms show significant improvement of the previous version.

  20. PDK2 and ABCG2 genes polymorphisms are correlated with blood glucose levels and uric acid in Tibetan gout patients.

    PubMed

    Ren, Y C; Jin, T B; Sun, X D; Geng, T T; Zhang, M X; Wang, L; Feng, T; Kang, L L; Chen, C

    2016-02-11

    Previous studies have shown that the PDK2 and ABCG2 genes play important roles in many aspects of gout development in European populations. However, a detailed genotype-phenotype analysis was not performed. The aim of the present study was to investigate the potential association between variants in these two genes and metabolism-related quantitative phenotypes relevant to gout in a Chinese Tibetan population. In total, 316 Chinese Tibetan gout patients were recruited from rheumatology outpatient clinics and 6 single nucleotide polymorphisms in PDK2 and ABCG2 were genotyped, which were possible etiologic variants as identified in the HapMap Chinese Han Beijing population. A significant difference in blood glucose levels was detected between different genotypes of rs2728109 (P = 0.005) in the PDK2 gene. We also detected a significant difference in the mean serum uric levels between different genotypes of rs3114018 (P = 0.004) in the ABCG2 gene. All P values remained significant after Bonferroni's correction for multiple testing. Our data demonstrate potential roles for PDK2 and ABCG2 polymorphisms in the metabolic phenotypes of Tibetan gout patients, which may provide new insights into the etiology of gout. Further studies are required to confirm these findings.

  1. Technology-based counseling in the management of weight and lifestyles of obese or overweight children and adolescents: A descriptive systematic literature review.

    PubMed

    Kaakinen, Pirjo; Kyngäs, Helvi; Kääriäinen, Maria

    2018-03-01

    The number of overweight and obese children and adolescents has increased worldwide. Obese children and adolescents need counseling interventions, including technology-based methods, to help them manage their weight by changing their lifestyles. To describe technology-based counseling interventions in supporting obese or overweight children and adolescents to change their weight/lifestyle. Descriptive systematic literature review. A literature search was conducted using Cinahl, Medline, PsycINFO, and Medic databases in September 2010 and updated in January 2015. Predefined inclusion criteria were used for the search. After a quality assessment, 28 studies were included in the data extraction. No statistically significant difference in BMI was detected between the intervention and control groups. However, in some studies, it was found that BMI decreases and there were statistically significant differences in fruit and vegetable consumption. In two studies, differences in physical activity were detected between the intervention and control groups, but in eight studies, the difference was not significant. Goal setting and feedback on progress support physical activity and changes in diet. This study identifies available technology interventions for obese or overweight children and adolescents. It seems that using technology-based counseling intervention may encourage obese and overweight children and adolescents to pursue a healthier lifestyle.

  2. Impact of molecular mechanisms, including deletion size, on Prader-Willi syndrome phenotype: study of 75 patients.

    PubMed

    Varela, M C; Kok, F; Setian, N; Kim, C A; Koiffmann, C P

    2005-01-01

    Prader-Willi syndrome (PWS) can result from a 15q11-q13 paternal deletion, maternal uniparental disomy (UPD), or imprinting mutations. We describe here the phenotypic variability detected in 51 patients with different types of deletions and 24 patients with UPD. Although no statistically significant differences could be demonstrated between the two main types of PWS deletion patients, it was observed that type I (BP1-BP3) patients acquired speech later than type II (BP2-BP3) patients. Comparing the clinical pictures of our patients with UPD with those with deletions, we found that UPD children presented with lower birth length and started walking earlier and deletion patients presented with a much higher incidence of seizures than UPD patients. In addition, the mean maternal age in the UPD group was higher than in the deletion group. No statistically significant differences could be demonstrated between the deletion and the UPD group with respect to any of the major features of PWS. In conclusion, our study did not detect significant phenotypic differences among type I and type II PWS deletion patients, but it did demonstrate that seizures were six times more common in patients with a deletion than in those with UPD.

  3. Psoriasis and wound healing outcomes: A retrospective cohort study examining wound complications and antibiotic use.

    PubMed

    Young, Paulina M; Parsi, Kory K; Schupp, Clayton W; Armstrong, April W

    2017-11-15

    Little is known about wound healing in psoriasis. We performed a cohort study examining differences in wound healing complications between patients with and without psoriasis. Psoriasis patients with traumatic wounds were matched 1:3 to non-psoriasis patients with traumatic wounds based on age, gender, and body mass index (BMI). We examined theincidence of wound complications including infection, necrosis, and hematoma as well as incident antibiotic use within three months following diagnosis of a traumatic wound. The study included 164 patients with traumatic wounds, comprised of 41 patients with psoriasis matched to 123 patients without psoriasis. No statistically significant differences were detected in the incidence of overall wound complications between wound patients with psoriasis and wound patients without psoriasis (14.6% versus. 13.0%, HR 1.18, CI 0.39-3.56). After adjustment for diabetes, peripheral vascular disease, and smoking, no statistically significant differences were detected in the incidence of overall wound complications between patients with and without psoriasis (HR 1.11, CI 0.34-3.58). Specifically, the adjusted rates of antibiotic use were not significantly different between those with and without psoriasis (HR 0.65, CI 0.29-1.46). The incidence of wound complications following traumatic wounds of the skin was found to be similar between patients with and without psoriasis.

  4. Porous Silicon Covered with Silver Nanoparticles as Surface-Enhanced Raman Scattering (SERS) Substrate for Ultra-Low Concentration Detection.

    PubMed

    Kosović, Marin; Balarin, Maja; Ivanda, Mile; Đerek, Vedran; Marciuš, Marijan; Ristić, Mira; Gamulin, Ozren

    2015-12-01

    Microporous and macro-mesoporous silicon templates for surface-enhanced Raman scattering (SERS) substrates were produced by anodization of low doped p-type silicon wafers. By immersion plating in AgNO3, the templates were covered with silver metallic film consisting of different silver nanostructures. Scanning electron microscopy (SEM) micrographs of these SERS substrates showed diverse morphology with significant difference in an average size and size distribution of silver nanoparticles. Ultraviolet-visible-near-infrared (UV-Vis-NIR) reflection spectroscopy showed plasmonic absorption at 398 and 469 nm, which is in accordance with the SEM findings. The activity of the SERS substrates was tested using rhodamine 6G (R6G) dye molecules and 514.5 nm laser excitation. Contrary to the microporous silicon template, the SERS substrate prepared from macro-mesoporous silicon template showed significantly broader size distribution of irregular silver nanoparticles as well as localized surface plasmon resonance closer to excitation laser wavelength. Such silver morphology has high SERS sensitivity that enables ultralow concentration detection of R6G dye molecules up to 10(-15) M. To our knowledge, this is the lowest concentration detected of R6G dye molecules on porous silicon-based SERS substrates, which might even indicate possible single molecule detection.

  5. Neuroimaging Evidence for 2 Types of Plasticity in Association with Visual Perceptual Learning.

    PubMed

    Shibata, Kazuhisa; Sasaki, Yuka; Kawato, Mitsuo; Watanabe, Takeo

    2016-09-01

    Visual perceptual learning (VPL) is long-term performance improvement as a result of perceptual experience. It is unclear whether VPL is associated with refinement in representations of the trained feature (feature-based plasticity), improvement in processing of the trained task (task-based plasticity), or both. Here, we provide empirical evidence that VPL of motion detection is associated with both types of plasticity which occur predominantly in different brain areas. Before and after training on a motion detection task, subjects' neural responses to the trained motion stimuli were measured using functional magnetic resonance imaging. In V3A, significant response changes after training were observed specifically to the trained motion stimulus but independently of whether subjects performed the trained task. This suggests that the response changes in V3A represent feature-based plasticity in VPL of motion detection. In V1 and the intraparietal sulcus, significant response changes were found only when subjects performed the trained task on the trained motion stimulus. This suggests that the response changes in these areas reflect task-based plasticity. These results collectively suggest that VPL of motion detection is associated with the 2 types of plasticity, which occur in different areas and therefore have separate mechanisms at least to some degree. © The Author 2016. Published by Oxford University Press.

  6. [Pharmacogenomics study of 620 whole-exome sequencing: focusing on aspirin application].

    PubMed

    Yang, L; Lu, Y L; Wang, H J; Zhou, W H

    2016-05-01

    To investigate the allele frequencies of aspirin-response-related variants in different population. The allele frequencies of reported clinically significant aspirin-response-related variants were evaluated based on 620 whole exome sequencing (WES) data collected from 2013 to 2016 in Children's Hospital of Fudan University.Then the local allele frequencies were compared with 1 000 Genomes project database, and χ(2) test was used. Thirty-eight aspirin-response-related variants that had clinical significance had been detected in the 620 WES data.Ten (26%) of them were related with drug efficacy while 28 (74%) were related with toxicity or adverse drug reaction (ADR). These variants were distributed in 33 genes.There were 23 aspirin-related variants further analysised, and the frequency of 7 (rs1050891, rs6065, rs7862221, rs1065776, rs3818822, rs3775291 and rs1126643) had no significant difference compared with frequency of European and East Asian population of 1 000 Genome project (P>0.01 for both), 10 (rs2228079, rs1613662, rs4523, rs28360521, rs1131882, rs1047626, rs3856806, rs2768759, rs7572857 and rs1126510) of them had no significant difference compared with East Asian but were significantly different from European population, 1 (rs2075797) had no significant difference compared with frequency of European and different with frequency of East Asian, and 5 variants(rs10279545, rs730012, rs16851030, rs1353411, rs1800469)were different from frequency of both East Asian(0.019, 0.058, 0.167, 0.452, 0.340 vs. 0.100, 0.151, 0.396, 0.568, 0.453, χ(2)=21.798, 20.400, 67.543, 16.531, 15.807, P all<0.01) and European population(0.531, 0.312, 0.037, 0.179, 0.688, χ(2)=325.799, 92.877, 144.811, 156.471, 174.533, P all<0.01). Most variants that have clinical significance in aspirin response are related with drug efficacy or drug toxicity or ADR, indicating the urgency of variants screen in clinical practice.Significant population-specificity is detected in local 620 WES data in aspirin-response-related variants.

  7. Between-Frequency and Between-Ear Gap Detections and Their Relation to Perception of Stop Consonants.

    PubMed

    Mori, Shuji; Oyama, Kazuki; Kikuchi, Yousuke; Mitsudo, Takako; Hirose, Nobuyuki

    2015-01-01

    The objective of this study was to examine the hypothesis that between-channel gap detection, which includes between-frequency and between-ear gap detection, and perception of stop consonants, which is mediated by the length of voice-onset time (VOT), share common mechanisms, namely relative-timing operation in monitoring separate perceptual channels. The authors measured gap detection thresholds and identification functions of /ba/ and /pa/ along VOT in 49 native young adult Japanese listeners. There were three gap detection tasks. In the between-frequency task, the leading and trailing markers differed in terms of center frequency (Fc). The leading marker was a broadband noise of 10 to 20,000 Hz. The trailing marker was a 0.5-octave band-passed noise of 1000-, 2000-, 4000-, or 8000-Hz Fc. In the between-ear task, the two markers were spectrally identical but presented to separate ears. In the within-frequency task, the two spectrally identical markers were presented to the same ear. The /ba/-/pa/ identification functions were obtained in a task in which the listeners were presented synthesized speech stimuli of varying VOTs from 10 to 46 msec and asked to identify them as /ba/ or /pa/. The between-ear gap thresholds were significantly positively correlated with the between-frequency gap thresholds (except those obtained with the trailing marker of 4000-Hz Fc). The between-ear gap thresholds were not significantly correlated with the within-frequency gap thresholds, which were significantly correlated with all the between-frequency gap thresholds. The VOT boundaries and slopes of /ba/-/pa/ identification functions were not significantly correlated with any of these gap thresholds. There was a close relation between the between-ear and between-frequency gap detection, supporting the view that these two types of gap detection share common mechanisms of between-channel gap detection. However, there was no evidence for a relation between the perception of stop consonants and the between-frequency/ear gap detection in native Japanese speakers.

  8. Optimization of programming parameters in children with the advanced bionics cochlear implant.

    PubMed

    Baudhuin, Jacquelyn; Cadieux, Jamie; Firszt, Jill B; Reeder, Ruth M; Maxson, Jerrica L

    2012-05-01

    Cochlear implants provide access to soft intensity sounds and therefore improved audibility for children with severe-to-profound hearing loss. Speech processor programming parameters, such as threshold (or T-level), input dynamic range (IDR), and microphone sensitivity, contribute to the recipient's program and influence audibility. When soundfield thresholds obtained through the speech processor are elevated, programming parameters can be modified to improve soft sound detection. Adult recipients show improved detection for low-level sounds when T-levels are set at raised levels and show better speech understanding in quiet when wider IDRs are used. Little is known about the effects of parameter settings on detection and speech recognition in children using today's cochlear implant technology. The overall study aim was to assess optimal T-level, IDR, and sensitivity settings in pediatric recipients of the Advanced Bionics cochlear implant. Two experiments were conducted. Experiment 1 examined the effects of two T-level settings on soundfield thresholds and detection of the Ling 6 sounds. One program set T-levels at 10% of most comfortable levels (M-levels) and another at 10 current units (CUs) below the level judged as "soft." Experiment 2 examined the effects of IDR and sensitivity settings on speech recognition in quiet and noise. Participants were 11 children 7-17 yr of age (mean 11.3) implanted with the Advanced Bionics High Resolution 90K or CII cochlear implant system who had speech recognition scores of 20% or greater on a monosyllabic word test. Two T-level programs were compared for detection of the Ling sounds and frequency modulated (FM) tones. Differing IDR/sensitivity programs (50/0, 50/10, 70/0, 70/10) were compared using Ling and FM tone detection thresholds, CNC (consonant-vowel nucleus-consonant) words at 50 dB SPL, and Hearing in Noise Test for Children (HINT-C) sentences at 65 dB SPL in the presence of four-talker babble (+8 signal-to-noise ratio). Outcomes were analyzed using a paired t-test and a mixed-model repeated measures analysis of variance (ANOVA). T-levels set 10 CUs below "soft" resulted in significantly lower detection thresholds for all six Ling sounds and FM tones at 250, 1000, 3000, 4000, and 6000 Hz. When comparing programs differing by IDR and sensitivity, a 50 dB IDR with a 0 sensitivity setting showed significantly poorer thresholds for low frequency FM tones and voiced Ling sounds. Analysis of group mean scores for CNC words in quiet or HINT-C sentences in noise indicated no significant differences across IDR/sensitivity settings. Individual data, however, showed significant differences between IDR/sensitivity programs in noise; the optimal program differed across participants. In pediatric recipients of the Advanced Bionics cochlear implant device, manually setting T-levels with ascending loudness judgments should be considered when possible or when low-level sounds are inaudible. Study findings confirm the need to determine program settings on an individual basis as well as the importance of speech recognition verification measures in both quiet and noise. Clinical guidelines are suggested for selection of programming parameters in both young and older children. American Academy of Audiology.

  9. Investigating the environmental control of planktonic proteobacterial groups during the phytoplankton spring bloom in two contrasting South Coast UK estuaries

    NASA Astrophysics Data System (ADS)

    Alshatti, Amani

    2017-04-01

    Seasonal changes in bacterioplankton populations in two south coast UK estuaries Southampton Water and Christchurch Harbour have been investigated between March and November 2013. Four different phylogenetic bacterial groups with two alphaproteobacteria clades were quantitatively determined in subsurface water samples by Fluorescence in-situ hybridization (FISH) with oligonucleotide probes during phytoplankton bloom periods. During the spring phytoplankton bloom in Southampton water, extracted chlorophyll-a concentrations of between 6.7 and 7.6 µg L-1 were detected while gammaproteobacteria relative abundances (28.7-32.8%) and alphaproteobacteria (35.0-44.0%) dominated the eubacteria with smaller proportions of betaproteobacteria (6.4-13.0%) under high salinity conditions (27.9-32.7). Gammaproteobacteria abundance was significantly negatively correlated with chlorophyll-a concentration (R =-0.5, p < 0.05). In the Christchurch Harbour estuary, betaproteobacteria (21.2-41.1%) dominated throughout the study period in lower salinity waters (1.3-20.7). A significant relationship with negative trend was detected in both estuaries between salinity and betaproteobacteria (R = - 0.95, p < 0.0001). A higher proportion of gammaproteobacteria (29.7-30.3 %) occurred after the spring bloom chlorophyll-a concentration of 5-44.3 µg L-1 and proportion of alphaproteobacteria was highly variable. Archaea were detected in low percentages throughout the blooming season in both estuaries with maximum detected relative abundances of 10.6% in Southampton water and 8.2% in Christchurch harbour. The variation in salinity range therefore between the two estuaries plus the differences in phytoplankton biomass had a marked influence on the dominance of the different proteobacterial groups detected.

  10. Model-based iterative reconstruction and adaptive statistical iterative reconstruction: dose-reduced CT for detecting pancreatic calcification.

    PubMed

    Yasaka, Koichiro; Katsura, Masaki; Akahane, Masaaki; Sato, Jiro; Matsuda, Izuru; Ohtomo, Kuni

    2016-01-01

    Iterative reconstruction methods have attracted attention for reducing radiation doses in computed tomography (CT). To investigate the detectability of pancreatic calcification using dose-reduced CT reconstructed with model-based iterative construction (MBIR) and adaptive statistical iterative reconstruction (ASIR). This prospective study approved by Institutional Review Board included 85 patients (57 men, 28 women; mean age, 69.9 years; mean body weight, 61.2 kg). Unenhanced CT was performed three times with different radiation doses (reference-dose CT [RDCT], low-dose CT [LDCT], ultralow-dose CT [ULDCT]). From RDCT, LDCT, and ULDCT, images were reconstructed with filtered-back projection (R-FBP, used for establishing reference standard), ASIR (L-ASIR), and MBIR and ASIR (UL-MBIR and UL-ASIR), respectively. A lesion (pancreatic calcification) detection test was performed by two blinded radiologists with a five-point certainty level scale. Dose-length products of RDCT, LDCT, and ULDCT were 410, 97, and 36 mGy-cm, respectively. Nine patients had pancreatic calcification. The sensitivity for detecting pancreatic calcification with UL-MBIR was high (0.67-0.89) compared to L-ASIR or UL-ASIR (0.11-0.44), and a significant difference was seen between UL-MBIR and UL-ASIR for one reader (P = 0.014). The area under the receiver-operating characteristic curve for UL-MBIR (0.818-0.860) was comparable to that for L-ASIR (0.696-0.844). The specificity was lower with UL-MBIR (0.79-0.92) than with L-ASIR or UL-ASIR (0.96-0.99), and a significant difference was seen for one reader (P < 0.01). In UL-MBIR, pancreatic calcification can be detected with high sensitivity, however, we should pay attention to the slightly lower specificity.

  11. Respiratory Viral Detections During Symptomatic and Asymptomatic Periods in Young Andean Children

    PubMed Central

    Howard, Leigh M.; Johnson, Monika; Williams, John V.; Zhu, Yuwei; Gil, Ana I.; Edwards, Kathryn M.; Griffin, Marie R.; Lanata, Claudio F.; Grijalva, Carlos G.

    2015-01-01

    Background Viruses are commonly detected in children with acute respiratory illnesses (ARI) and in asymptomatic children. Longitudinal studies of viral detections during asymptomatic periods surrounding ARI could facilitate interpretation of viral detections but are currently scant. Methods We used reverse transcription-polymerase chain reaction (RT-PCR) to analyze respiratory samples from young Andean children for viruses during asymptomatic periods within 8-120 days of index ARI (cough or fever). We compared viral detections over time within children and explored RT-PCR cycle thresholds (CT) as surrogates for viral loads. Results At least one respiratory virus was detected in 367 (43%) of 859 samples collected during asymptomatic periods, with more frequent detections in periods with rhinorrhea (49%) than those without (34%, p<0.001). Relative to index ARI with human rhinovirus (HRV), adenovirus (AdV), respiratory syncytial virus (RSV), and parainfluenza virus (PIV) detected, the same virus was also detected during 32%, 22%, 10%, and 3% of asymptomatic periods, respectively. RSV was only detected 8-30 days after index RSV ARI, whereas HRV and AdV were detected throughout asymptomatic periods. Human metapneumovirus (MPV) and influenza were rarely detected during asymptomatic periods (<3%). No significant differences were observed in the CT for HRV or AdV during asymptomatic periods relative to ARI. For RSV, CT were significantly lower during ARI relative to the asymptomatic period (p=0.03). Conclusions These findings indicate that influenza, MPV, PIV, and RSV detections in children with ARI usually indicate a causal relationship. When HRV or AdV is detected during ARI, the causal relationship is less certain. PMID:26121205

  12. Chlamydia Detection during the Menstrual Cycle: A Cross-Sectional Study of Women Attending a Sexual Health Service

    PubMed Central

    Forcey, Dana S.; Hocking, Jane S.; Tabrizi, Sepehr N.; Bradshaw, Catriona S.; Chen, Marcus Y.; Fehler, Glenda; Nash, Jessica L.; Fairley, Christopher K.

    2014-01-01

    Background We investigated the detection of chlamydia at different stages of the menstrual cycle. Methods Electronic medical records for women attending Melbourne Sexual Health Centre between March 2011 and 31st December 2012, who were tested for chlamydia by nucleic acid amplification of high vaginal, cervical, or urinary samples, and who recorded a date of last normal menstrual period (LNMP) between 0–28 days were included in the analysis. Logistic regression was used to calculate adjusted odds ratio (aOR) and 95% confidence intervals (CI) for the association of chlamydia with menstrual cycle adjusted by demographics and behavioural variables. Chlamydia and beta globin load were determined on those with stored samples. Results Of the 10,017 consultations that included a test for chlamydia and a valid LNMP, there were 417 in which chlamydia was detected. The proportion of samples with chlamydia was greater in the luteal phase (4.8%, 184/3831) than in the follicular phase (3.4%, 233/6816) both in the crude (OR 1.29 95%CI 1.1–1.6, p = 0.01) and adjusted odds ratio (aOR) 1.4 (95%CI 1.1–1.8, p = 0.004). Among women using hormonal contraception, there was no significant association with the luteal phase of the menstrual cycle (aOR 1.3, 95%CI 0.9, 1.8, p = 0.18). Among women not using hormonal contraception, there was a significant association with the luteal phase (aOR 1.6, (95% CI 1.1–2.3, p = 0.007). The chlamydia load was not significantly different in the 329 positive stored samples in weeks 3 and 4 vs weeks 1 and 2 for any site (P>0.12). Conclusions The higher detection of chlamydia detection in the luteal phase of the menstrual cycle in only those not taking hormonal contraception suggest that hormonal factors influence chlamydia detection. The absence of a significantly highly chlamydia load in women during the luteal phase raises questions about the mechanism. PMID:24475042

  13. Intravitreal invading cells contribute to vitreal cytokine milieu in proliferative vitreoretinopathy

    PubMed Central

    El-Ghrably, I; Dua, H.; Orr, G.; Fischer, D.; Tighe, P.

    2001-01-01

    AIM—To examine the contribution of infiltrating cells in the local production of cytokines within the vitreous of patients with proliferative vitreoretinopathy (PVR).
METHODS—The presence of mRNA coding for IL-6, IL-8, IL-1β, IL-1α, TNFα, IFNγ, IL-12, and HPRT was investigated in 25 vitreous samples from patients with PVR, 11 vitreous samples from patients with retinal detachment (RD) not complicated by PVR, and 10 vitreous samples from patients with macular hole (MH). A quantitative reverse transcriptase polymerase chain reaction (RT-PCR) using an internal competitor was used to investigate these samples. From these samples, 15 PVR, 8 RD, and 8 MH were analysed for the protein levels of the same cytokines using enzyme linked immunosorbent assay (ELISA). Spearman correlation was used to test any association between mRNA and cytokine protein levels, as an indicator of the contribution these cells make to the intravitreal cytokine milieu.
RESULTS—A strong correlation was found between mRNA and their respective cytokine levels (protein products) for IL-6, IL-8, IL-1β, IL-1α, TNFα, IFNγ (Spearman r = 0.83, 0.73, 0.67, 0.91, 0.73, and 0.73 respectively), but not for IL-12. The median levels of IL-6, IL-8, IL-1β, and IFNγ mRNA and their respective cytokines were significantly higher (p <0.05) in patients with PVR than in those with macular hole. There was no statistically significant difference in the median levels of IL-1α mRNA between PVR and MH but the cytokine IL-1α was detected at a significantly higher level in PVR compared with MH patients. Between PVR and RD patients, there was no statistically significant difference in mRNA levels for all the investigated cytokines (p >0.05) except for IL-6 where there was a statistical significance (p= 0.038). In contrast, the median levels of IL-6, IL-8, and IL-1β cytokines were significantly higher (p <0.05) in patients with PVR than in those with RD, whereas for IL-1α and IFNγ no significant statistical difference was detected between PVR and RD patients (p >0.05). When results of RD and MH patients were compared, a statistical difference was only detected in mRNA levels of INFγ (p = 0.008). However, no difference was detected for INFγ (protein product) or for any of the other cytokines between RD and MH patients.
CONCLUSION—Levels of both protein and mRNA encoding IL-6, IL-8, IL-1β, and IFNγ is significantly increased in vitreous samples from patients with PVR. The strong correlation between ELISA detectable cytokines (protein products) and their respective mRNA levels suggest that intravitreal, invasive cells are the major source of these cytokines, with the exception of IL-12. Cells invading the vitreous do not appear to locally produce IL-12 mRNA. This would appear to implicate cells peripheral to the vitreal mass as the major source of this cytokine.

 PMID:11264138

  14. An infrared small target detection method based on multiscale local homogeneity measure

    NASA Astrophysics Data System (ADS)

    Nie, Jinyan; Qu, Shaocheng; Wei, Yantao; Zhang, Liming; Deng, Lizhen

    2018-05-01

    Infrared (IR) small target detection plays an important role in the field of image detection area owing to its intrinsic characteristics. This paper presents a multiscale local homogeneity measure (MLHM) for infrared small target detection, which can enhance the performance of IR small target detection system. Firstly, intra-patch homogeneity of the target itself and the inter-patch heterogeneity between target and the local background regions are integrated to enhance the significant of small target. Secondly, a multiscale measure based on local regions is proposed to obtain the most appropriate response. Finally, an adaptive threshold method is applied to small target segmentation. Experimental results on three different scenarios indicate that the MLHM has good performance under the interference of strong noise.

  15. Spatial-temporal event detection in climate parameter imagery.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenna, Sean Andrew; Gutierrez, Karen A.

    Previously developed techniques that comprise statistical parametric mapping, with applications focused on human brain imaging, are examined and tested here for new applications in anomaly detection within remotely-sensed imagery. Two approaches to analysis are developed: online, regression-based anomaly detection and conditional differences. These approaches are applied to two example spatial-temporal data sets: data simulated with a Gaussian field deformation approach and weekly NDVI images derived from global satellite coverage. Results indicate that anomalies can be identified in spatial temporal data with the regression-based approach. Additionally, la Nina and el Nino climatic conditions are used as different stimuli applied to themore » earth and this comparison shows that el Nino conditions lead to significant decreases in NDVI in both the Amazon Basin and in Southern India.« less

  16. Artificial Neural Network applied to lightning flashes

    NASA Astrophysics Data System (ADS)

    Gin, R. B.; Guedes, D.; Bianchi, R.

    2013-05-01

    The development of video cameras enabled cientists to study lightning discharges comportment with more precision. The main goal of this project is to create a system able to detect images of lightning discharges stored in videos and classify them using an Artificial Neural Network (ANN)using C Language and OpenCV libraries. The developed system, can be split in two different modules: detection module and classification module. The detection module uses OpenCV`s computer vision libraries and image processing techniques to detect if there are significant differences between frames in a sequence, indicating that something, still not classified, occurred. Whenever there is a significant difference between two consecutive frames, two main algorithms are used to analyze the frame image: brightness and shape algorithms. These algorithms detect both shape and brightness of the event, removing irrelevant events like birds, as well as detecting the relevant events exact position, allowing the system to track it over time. The classification module uses a neural network to classify the relevant events as horizontal or vertical lightning, save the event`s images and calculates his number of discharges. The Neural Network was implemented using the backpropagation algorithm, and was trained with 42 training images , containing 57 lightning events (one image can have more than one lightning). TheANN was tested with one to five hidden layers, with up to 50 neurons each. The best configuration achieved a success rate of 95%, with one layer containing 20 neurons (33 test images with 42 events were used in this phase). This configuration was implemented in the developed system to analyze 20 video files, containing 63 lightning discharges previously manually detected. Results showed that all the lightning discharges were detected, many irrelevant events were unconsidered, and the event's number of discharges was correctly computed. The neural network used in this project achieved a success rate of 90%. The videos used in this experiment were acquired by seven video cameras installed in São Bernardo do Campo, Brazil, that continuously recorded lightning events during the summer. The cameras were disposed in a 360 loop, recording all data at a time resolution of 33ms. During this period, several convective storms were recorded.

  17. [Sensitivity and specificity of nested PCR pyrosequencing in hepatitis B virus drug resistance gene testing].

    PubMed

    Sun, Shumei; Zhou, Hao; Zhou, Bin; Hu, Ziyou; Hou, Jinlin; Sun, Jian

    2012-05-01

    To evaluate the sensitivity and specificity of nested PCR combined with pyrosequencing in the detection of HBV drug-resistance gene. RtM204I (ATT) mutant and rtM204 (ATG) nonmutant plasmids mixed at different ratios were detected for mutations using nested-PCR combined with pyrosequencing, and the results were compared with those by conventional PCR pyrosequencing to analyze the linearity and consistency of the two methods. Clinical specimens with different viral loads were examined for drug-resistant mutations using nested PCR pyrosequencing and nested PCR combined with dideoxy sequencing (Sanger) for comparison of the detection sensitivity and specificity. The fitting curves demonstrated good linearity of both conventional PCR pyrosequencing and nested PCR pyrosequencing (R(2)>0.99, P<0.05). Nested PCR showed a better consistency with the predicted value than conventional PCR, and was superior to conventional PCR for detection of samples containing 90% mutant plasmid. In the detection of clinical specimens, Sanger sequencing had a significantly lower sensitivity than nested PCR pyrosequencing (92% vs 100%, P<0.01). The detection sensitivity of Sanger sequencing varied with the viral loads, especially in samples with low viral copies (HBV DNA ≤3log10 copies/ml), where the sensitivity was 78%, significantly lower than that of pyrosequencing (100%, P<0.01). Neither of the two methods yielded positive results for the negative control samples, suggesting their good specificity. Compared with nested PCR and Sanger sequencing method, nested PCR pyrosequencing has a higher sensitivity especially in clinical specimens with low viral copies, which can be important for early detection of HBV mutant strains and hence more effective clinical management.

  18. Evaluating a switch from meconium to umbilical cord tissue for newborn drug testing: A retrospective study at an academic medical center.

    PubMed

    Palmer, Kendra L; Wood, Kelly E; Krasowski, Matthew D

    2017-04-01

    The objective of this study was to compare detection rates of newborn drug exposure at an academic medical center transitioning from meconium to umbilical cord tissue toxicology testing. We performed an Institutional Review Board-approved retrospective chart review on all newborns (n=2072) for whom newborn drug testing was ordered at our academic medical center between June 2012 and August 2015 (in August 2013, umbilical cord tissue became the preferred specimen). Meconium toxicology testing was positive for at least one compound in 221 cases (21.3% of 1037 total specimens), with non-medical drug use identified in 85 cases (8.2%). Umbilical cord tissue toxicology testing was positive for at least one compound in 302 cases (29.2%), with non-medical drug use identified in 107 cases (10.3%). Of the cases involving non-medical drug use, the most common compounds detected were tetrahydrocannabinol and amphetamines. Non-medical drug use did not differ significantly between meconium and umbilical cord tissue, either as a total or for classes of drugs such as amphetamines, cannabinoids, and opiates. Maternal non-medical use of tramadol (not tested for in meconium) was identified in 5 cases (0.4%). There were significant differences in rate of detection of iatrogenic medications. Specifically, morphine, lorazepam, phenobarbital, and codeine were more commonly detected in meconium, while oxycodone was more commonly detected in umbilical cord tissue. Umbilical cord tissue toxicology testing yielded a similar detection rate compared to meconium testing. The use of umbilical cord tissue avoids detection of medications given to the neonate prior to meconium collection. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Determination of chlorinated insecticides in bottom sediment using an electron-capture gas chromatography screening method, Austin, Texas, 1991 and 1992

    USGS Publications Warehouse

    Brock, Robert D.; Murtagh, Lucinda K.

    1994-01-01

    Twenty-two bottom-sediment samples were collected from Town Lake in Austin, Texas, in 1991 and 1992 and analyzed for chlorinated insecticides by a reconnaissance-quality, electron-capture gas chromatography screening method developed by the U.S. Geological Survey (USGS). Four different chlorinated insecticides (aldrin, chlordane, dieldrin, and p,p'-DDT) and two degradation products of p,p'-DDT (p,p'-DDD and p,p'-DDE) were detected in these samples. The most significant insecticides detected were chlordane, which was detected in 20 of the 22 samples at concentrations that ranged from 26 to 140 micrograms per kilogram, and p,p'-DDT, which was detected in all 22 samples at concen- trations that ranged from 5 to 40 micrograms per kilogram. Degradation products of p,p'-DDT were detected in all 22 samples. Concentrations of p,p'-DDD ranged from not detected to 117 micrograms per kilogram and for p,p'-DDE from 9 to 97 micrograms per kilogram. Of the 22 samples collected, 15 also were analyzed by the standard USGS laboratory analytical method for chlorinated insecticides to determine the comparability of the two methods. Correlation coefficients were calculated for chlordane (0.8662), p,p'-DDT (0.6393), p,p'-DDD (0.9401), p,p'-DDE (0.8595), and dieldrin (0.3819). A paired sign test at the 95 percent confidence level showed no significant difference between the screening method and laboratory analytical method for all detected insecticides except aldrin. P-values were calculated from the data for chlordane (l.0000), p,p'-DDT (0.1796), p,p'-DDD (l,0000), p,p'-DDE (0.1796), and dieldrin (0.2891).

  20. Oxytocin administration selectively improves olfactory detection thresholds for lyral in patients with schizophrenia

    PubMed Central

    Woolley, J.D.; Lam, O.; Chuang, B.; Ford, J.M.; Mathalon, D.H.; Vinogradov, S.

    2015-01-01

    Summary Background Olfaction plays an important role in mammalian social behavior. Olfactory deficits are common in schizophrenia and correlate with negative symptoms and low social drive. Despite their prominence and possible clinical relevance, little is understood about the pathological mechanisms underlying olfactory deficits in schizophrenia and there are currently no effective treatments for these deficits. The prosocial neuropeptide oxytocin may affect the olfactory system when administered intranasally to humans and there is growing interest in its therapeutic potential in schizophrenia. Methods To examine this model, we administered 40 IU of oxytocin and placebo intranasally to 31 patients with a schizophrenia spectrum illness and 34 age-matched healthy control participants in a randomized, double-blind, placebo-controlled, cross-over study. On each test day, participants completed an olfactory detection threshold test for two different odors: (1) lyral, a synthetic fragrance compound for which patients with schizophrenia have specific olfactory detection threshold deficits, possibly related to decreased cyclic adenosine 3′,5′-monophosphate (cAMP) signaling; and (2) anise, a compound for which olfactory detection thresholds change with menstrual cycle phase in women. Results On the placebo test day, patients with schizophrenia did not significantly differ from healthy controls in detection of either odor. We found that oxytocin administration significantly and selectively improved olfactory detection thresholds for lyral but not for anise in patients with schizophrenia. In contrast, oxytocin had no effect on detection of either odor in healthy controls. Discussion Our data indicate that oxytocin administration may ameliorate olfactory deficits in schizophrenia and suggest the effects of intranasal oxytocin may extend to influencing the olfactory system. Given that oxytocin has been found to increase cAMP signaling in vitro a possible mechanism for these effects is discussed. PMID:25637811

  1. Oxytocin administration selectively improves olfactory detection thresholds for lyral in patients with schizophrenia.

    PubMed

    Woolley, J D; Lam, O; Chuang, B; Ford, J M; Mathalon, D H; Vinogradov, S

    2015-03-01

    Olfaction plays an important role in mammalian social behavior. Olfactory deficits are common in schizophrenia and correlate with negative symptoms and low social drive. Despite their prominence and possible clinical relevance, little is understood about the pathological mechanisms underlying olfactory deficits in schizophrenia and there are currently no effective treatments for these deficits. The prosocial neuropeptide oxytocin may affect the olfactory system when administered intranasally to humans and there is growing interest in its therapeutic potential in schizophrenia. To examine this model, we administered 40IU of oxytocin and placebo intranasally to 31 patients with a schizophrenia spectrum illness and 34 age-matched healthy control participants in a randomized, double-blind, placebo-controlled, cross-over study. On each test day, participants completed an olfactory detection threshold test for two different odors: (1) lyral, a synthetic fragrance compound for which patients with schizophrenia have specific olfactory detection threshold deficits, possibly related to decreased cyclic adenosine 3',5'-monophosphate (cAMP) signaling; and (2) anise, a compound for which olfactory detection thresholds change with menstrual cycle phase in women. On the placebo test day, patients with schizophrenia did not significantly differ from healthy controls in detection of either odor. We found that oxytocin administration significantly and selectively improved olfactory detection thresholds for lyral but not for anise in patients with schizophrenia. In contrast, oxytocin had no effect on detection of either odor in healthy controls. Our data indicate that oxytocin administration may ameliorate olfactory deficits in schizophrenia and suggest the effects of intranasal oxytocin may extend to influencing the olfactory system. Given that oxytocin has been found to increase cAMP signaling in vitro a possible mechanism for these effects is discussed. Published by Elsevier Ltd.

  2. Effectiveness of fluorescence-based methods to detect in situ demineralization and remineralization on smooth surfaces.

    PubMed

    Moriyama, C M; Rodrigues, J A; Lussi, A; Diniz, M B

    2014-01-01

    This study aimed to evaluate the effectiveness of fluorescence-based methods (DIAGNOdent, LF; DIAGNOdent pen, LFpen, and VistaProof fluorescence camera, FC) in detecting demineralization and remineralization on smooth surfaces in situ. Ten volunteers wore acrylic palatal appliances, each containing 6 enamel blocks that were demineralized for 14 days by exposure to a 20% sucrose solution and 3 of them were remineralized for 7 days with fluoride dentifrice. Sixty enamel blocks were evaluated at baseline, after demineralization and 30 blocks after remineralization by two examiners using LF, LFpen and FC. They were submitted to surface microhardness (SMH) and cross-sectional microhardness analysis. The integrated loss of surface hardness (ΔKHN) was calculated. The intraclass correlation coefficient for interexaminer reproducibility ranged from 0.21 (FC) to 0.86 (LFpen). SMH, LF and LFpen values presented significant differences among the three phases. However, FC fluorescence values showed no significant differences between the demineralization and remineralization phases. Fluorescence values for baseline, demineralized and remineralized enamel were, respectively, 5.4 ± 1.0, 9.2 ± 2.2 and 7.0 ± 1.5 for LF; 10.5 ± 2.0, 15.0 ± 3.2 and 12.5 ± 2.9 for LFpen, and 1.0 ± 0.0, 1.0 ± 0.1 and 1.0 ± 0.1 for FC. SMH and ΔKHN showed significant differences between demineralization and remineralization phases. There was a negative and significant correlation between SMH and LF and LFpen in the remineralization phase. In conclusion, LF and LFpen devices were effective in detecting demineralization and remineralization on smooth surfaces provoked in situ.

  3. Diffusion tensor imaging can detect the early stages of cartilage damage: a comparison study.

    PubMed

    Ukai, Taku; Sato, Masato; Yamashita, Tomohiro; Imai, Yutaka; Mitani, Genya; Takagaki, Tomonori; Serigano, Kenji; Mochida, Joji

    2015-02-21

    In the present study, we measured damaged areas of cartilage with diffusion tensor (DT) imaging and T2 mapping, and investigated the extent to which cartilage damage could be determined using these techniques. Forty-one patients underwent arthroscopic knee surgery for osteoarthritis of the knee, a meniscus injury, or an anterior cruciate ligament injury. Preoperative magnetic resonance imaging of the knee was performed, including T2 mapping and diffusion tensor imaging. The presence of cartilage injury involving the medial and lateral femoral condyles and tibia plateau was assessed during surgery using the Outerbridge scale. The ADC, T2 values and fractional anisotropy of areas of cartilage injury were then retrospectively analysed. The ADC results identified significant differences between Outerbridge grades 0 and 2 (P = 0.041); 0 and 3 (P < 0.001); 1 and 2 (P = 0.045); 1 and 3 (P < 0.001); and 2 and 3 (P = 0.028). The FA results identified significant differences between grades 0 and 1 (P < 0.001); 0 and 2 (P < 0.001); and 0 and 3 (P < 0.001). T2 mapping identified significant differences between Outerbridge grades 0 and 2 (P = 0.032); 0 and 3 (P < 0.001); 1 and 3 (P < 0.001); and 2 and 3 (P < 0.001). Both the T2 mapping (R(2) = 0.7883) and the ADC (R(2) = 0.9184) correlated significantly with the Outerbridge grade. The FA (R(2) = 0.6616) correlated slightly with the Outerbridge grade. T2 mapping can be useful for detecting moderate or severe cartilage damage, and the ADC can be used to detect early stage cartilage damage. The FA can also distinguish normal from damaged cartilage.

  4. ACE and ACTN3 genes polymorphisms among female Hungarian athletes in the aspect of sport disciplines.

    PubMed

    Bosnyák, E; Trájer, E; Udvardy, A; Komka, Z; Protzner, A; Kováts, T; Györe, I; Tóth, M; Pucsok, J; Szmodis, M

    2015-12-01

    The aim of the study was to determine the importance of two sport-associated gene polymorphisms, alpha-actinin-3 R577X (ACTN3) and angiotensin-converting enzyme I/D (ACE), among Hungarian athletes in different sports. The examination was carried out only on women (n = 100). Sport-specific groups were formed in order to guarantee the most homogeneous clusters. Human genomic DNA was isolated from blood, and genotyping was performed by polymerase chain reaction. To measure the differences between the participating groups, Chi-squared test was performed using Statistica 9.0 for Windows® (significance level: p < 0.05). In comparing the ACE I/D allele frequencies, significant difference was detected between water polo (I = 61.11%; D = 38.89%) and combat sports (I = 35.71%, D = 64.29%) athletes (p < 0.03). There was no statistical difference when ACE I/D alleles in combat sports and kayaking/rowing (p > 0.05) were compared. A similarity was detectable in the I allele frequencies of the water polo (61.11%) and kayaking/rowing (56.67%) groups. The ACTN3 R/X polymorphism showed no differences in comparison with the sport groups. R allele frequencies were higher in every group compared to the X allele. The potential significance of the ACE I allele in sports of an aerobic nature was not clearly confirmed among Hungarian athletes.

  5. The current and future role of magnetic resonance imaging in prostate cancer detection and management

    PubMed Central

    Radtke, Jan Philipp; Teber, Dogu; Hohenfellner, Markus

    2015-01-01

    Purpose Accurate detection of clinically significant prostate cancer (PC) and correct risk attribution are essential to individually counsel men with PC. Multiparametric MRI (mpMRI) facilitates correct localization of index lesions within the prostate and MRI-targeted prostate biopsy (TPB) helps to avoid the shortcomings of conventional biopsy such as false-negative results or underdiagnosis of aggressive PC. In this review we summarize the different sequences of mpMRI, characterize the possibilities of incorporating MRI in the biopsy workflow and outline the performance of targeted and systematic cores in significant cancer detection. Furthermore, we outline the potential of MRI in patients undergoing active surveillance (AS) and in the pre-operative setting. Materials and methods An electronic MEDLINE/PubMed search up to February 2015 was performed. English language articles were reviewed for inclusion ability and data were extracted, analyzed and summarized. Results Targeted biopsies significantly outperform conventional systematic biopsies in the detection of significant PC and are not inferior when compared to transperineal saturation biopsies. MpMRI can detect index lesions in app. 90% of cases as compared to prostatectomy specimen. The diagnostic performance of biparametric MRI (T2w + DWI) is not inferior to mpMRI, offering options to diminish cost- and time-consumption. Since app 10% of significant lesions are still MRI-invisible, systematic cores seem to be necessary. In-bore biopsy and MRI/TRUS-fusion-guided biopsy tend to be superior techniques compared to cognitive fusion. In AS, mpMRI avoids underdetection of significant PC and confirms low-risk disease accurately. In higher-risk disease, pre-surgical MRI can change the clinically-based surgical plan in up to a third of cases. Conclusions mpMRI and targeted biopsies are able to detect significant PC accurately and mitigate insignificant PC detection. As long as the negative predictive value (NPV) is still imperfect, systematic cores should not be omitted for optimal staging of disease. The potential to correctly classify aggressiveness of disease in AS patients and to guide and plan prostatectomy is evolving. PMID:26816833

  6. Prognosis for Mammographically Occult, Early-Stage Breast Cancer Patients Treated With Breast-Conservation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Tzu-I. J.; Yang Qifeng; Department of Breast Surgery, Qilu Hospital, Shandong University, Jinan

    2010-01-15

    Purpose: To compare mammographically occult (MamOcc) and mammographically positive (MamPos) early-stage breast cancer patients treated with breast-conservation therapy (BCT), to analyze differences between the two cohorts. Methods and Materials: Our two cohorts consisted of 214 MamOcc and 2168 MamPos patients treated with BCT. Chart reviews were conducted to assess mammogram reports and method of detection. All clinical-pathologic and outcome parameters were analyzed to detect differences between the two cohorts. Results: Median follow-up was 7 years. There were no differences in final margins, T stage, nodal status, estrogen/progesterone receptor status, or 'triple-negative' status. Significant differences included younger age at diagnosis (pmore » < 0.0001), more positive family history (p = 0.0033), less HER-2+ disease (p = 0.0294), and 1{sup o} histology (p < 0.0001). At 10 years, the differences in overall survival, cause-specific survival, and distant relapse between the two groups did not differ significantly. The MamOcc cohort had more breast relapses (15% vs. 8%; p = 0.0357), but on multivariate analysis this difference was not significant (hazard ratio 1.0, 95% confidence interval 0.993-1.007, p = 0.9296). Breast relapses were mammographically occult in 32% of the MamOcc and 12% of the MamPos cohorts (p = 0.0136). Conclusions: Although our study suggests that there are clinical-pathologic variations for the MamOcc cohort vs. MamPos patients that may ultimately affect management, breast relapse after BCT was not significantly different. Breast recurrences were more often mammographically occult in the MamOcc cohort; consideration should be given to closer follow-up and alternative imaging strategies (ultrasound, breast MRI) for routine posttreatment examination. To our knowledge, this represents the largest series addressing the prognostic significance of MamOcc cancers treated with BCT.« less

  7. Pedestrian detection based on redundant wavelet transform

    NASA Astrophysics Data System (ADS)

    Huang, Lin; Ji, Liping; Hu, Ping; Yang, Tiejun

    2016-10-01

    Intelligent video surveillance is to analysis video or image sequences captured by a fixed or mobile surveillance camera, including moving object detection, segmentation and recognition. By using it, we can be notified immediately in an abnormal situation. Pedestrian detection plays an important role in an intelligent video surveillance system, and it is also a key technology in the field of intelligent vehicle. So pedestrian detection has very vital significance in traffic management optimization, security early warn and abnormal behavior detection. Generally, pedestrian detection can be summarized as: first to estimate moving areas; then to extract features of region of interest; finally to classify using a classifier. Redundant wavelet transform (RWT) overcomes the deficiency of shift variant of discrete wavelet transform, and it has better performance in motion estimation when compared to discrete wavelet transform. Addressing the problem of the detection of multi-pedestrian with different speed, we present an algorithm of pedestrian detection based on motion estimation using RWT, combining histogram of oriented gradients (HOG) and support vector machine (SVM). Firstly, three intensities of movement (IoM) are estimated using RWT and the corresponding areas are segmented. According to the different IoM, a region proposal (RP) is generated. Then, the features of a RP is extracted using HOG. Finally, the features are fed into a SVM trained by pedestrian databases and the final detection results are gained. Experiments show that the proposed algorithm can detect pedestrians accurately and efficiently.

  8. Comparison Between Various Color Spectra and Conventional Grayscale Imaging for Detection of Parenchymal Liver Lesions With B-Mode Sonography.

    PubMed

    Merkel, Daniel; Brinkmann, Eckard; Kämmer, Joerg C; Köhler, Miriam; Wiens, Daniel; Derwahl, Karl-Michael

    2015-09-01

    The electronic colorization of grayscale B-mode sonograms using various color schemes aims to enhance the adaptability and practicability of B-mode sonography in daylight conditions. The purpose of this study was to determine the diagnostic effectiveness and importance of colorized B-mode sonography. Fifty-three video sequences of sonographic examinations of the liver were digitized and subsequently colorized in 2 different color combinations (yellow-brown and blue-white). The set of 53 images consisted of 33 with isoechoic masses, 8 with obvious lesions of the liver (hypoechoic or hyperechoic), and 12 with inconspicuous reference images of the liver. The video sequences were combined in a random order and edited into half-hour video clips. Isoechoic liver lesions were successfully detected in 58% of the yellow-brown video sequences and in 57% of the grayscale video sequences (P = .74, not significant). Fifty percent of the isoechoic liver lesions were successfully detected in the blue-white video sequences, as opposed to a 55% detection rate in the corresponding grayscale video sequences (P= .11, not significant). In 2 subgroups, significantly more liver lesions were detected with grayscale sonography compared to blue-white sonography. Yellow-brown-colorized B-mode sonography appears to be similarly effective for detection of isoechoic parenchymal liver lesions as traditional grayscale sonography. Blue-white colorization in B-mode sonography is probably not as effective as grayscale sonography, although a statistically significant disadvantage was shown only in the subgroup of hyperechoic liver lesions. © 2015 by the American Institute of Ultrasound in Medicine.

  9. Potential chemical markers for the identification of irradiated sausages.

    PubMed

    Kwon, Joong Ho; Akram, Kashif; Nam, Ki Chang; Min, Byungrok; Lee, Eun Joo; Ahn, Dong U

    2012-09-01

    Hydrocarbons, gas compounds, and off-odor volatiles were determined for irradiated (0 or 5 kGy) commercial sausages with different fat contents (16% and 29%) during a 60-d storage period at 4 °C. Total of 4 hydrocarbons (C14:1, C15:0, C16:2, and C17:1) were detected only in irradiated sausages: the amount of C16:2 was the highest, followed by C17:1, C14:1, and C15:0. The concentrations of hydrocarbons decreased significantly (P < 0.05) with storage, but were still detectable at the end of 60-d storage. Irradiated sausages produced significantly higher amounts of CO than the nonirradiated ones. CH(4) was detected only in irradiated sausages. Dimethyl disulfide was detected only in irradiated sausages and its concentration decreased significantly (P < 0.05) with storage. Fat content of sausages showed a significant effect on the production and retention of hydrocarbons, gas compounds, and sulfur volatiles in irradiated sausages during storage. Some hydrocarbons (C16:2, C17:1, C14:1, and C15:0), CH(4) , and dimethyl disulfide were only found in irradiated sausages indicating that these compounds can be used as potential markers for irradiated sausages. © 2012 Institute of Food Technologists®

  10. Improved Detection of Vowel Envelope Frequency Following Responses Using Hotelling's T2 Analysis.

    PubMed

    Vanheusden, Frederique J; Bell, Steven L; Chesnaye, Michael A; Simpson, David M

    2018-05-11

    Objective detection of brainstem responses to natural speech stimuli is an important tool for the evaluation of hearing aid fitting, especially in people who may not be able to respond reliably in behavioral tests. Of particular interest is the envelope frequency following response (eFFR), which refers to the EEG response at the stimulus' fundamental frequency (and its harmonics), and here in particular to the response to natural spoken vowel sounds. This article introduces the frequency-domain Hotelling's T (HT2) method for eFFR detection. This method was compared, in terms of sensitivity in detecting eFFRs at the fundamental frequency (HT2_F0), to two different single-channel frequency domain methods (F test on Fourier analyzer (FA) amplitude spectra [FA-F-Test] and magnitude-squared coherence [MSC]) in detecting envelope following responses to natural vowel stimuli in simulated data and EEG data from normal-hearing subjects. Sensitivity was assessed based on the number of detections and the time needed to detect a response for a false-positive rate of 5%. The study also explored whether a single-channel, multifrequency HT2 (HT2_3F) and a multichannel, multifrequency HT2 (HT2_MC) could further improve response detection. Four repeated words were presented sequentially at 70 dB SPL LAeq through ER-2 insert earphones. The stimuli consisted of a prolonged vowel in a /hVd/ structure (where V represents different vowel sounds). Each stimulus was presented over 440 sweeps (220 condensation and 220 rarefaction). EEG data were collected from 12 normal-hearing adult participants. After preprocessing and artifact removal, eFFR detection was compared between the algorithms. For the simulation study, simulated EEG signals were generated by adding random noise at multiple signal to noise ratios (SNRs; 0 to -60dB) to the auditory stimuli as well as to a single sinusoid at the fluctuating and flattened fundamental frequency (f0). For each SNR, 1000 sets of 440 simulated epochs were generated. Performance of the algorithms was assessed based on the number of sets for which a response could be detected at each SNR. In simulation studies, HT2_3F significantly outperformed the other algorithms when detecting a vowel stimulus in noise. For simulations containing responses only at a single frequency, HT2_3F performs worse compared with other approaches applied in this study as the additional frequencies included do not contain additional information. For recorded EEG data, HT2_MC showed a significantly higher response detection rate compared with MSC and FA-F-Test. Both HT2_MC and HT2_F0 also showed a significant reduction in detection time compared with the FA-F-Test algorithm. Comparisons between different electrode locations confirmed a higher number of detections for electrodes close to Cz compared to more peripheral locations. The HT2 method is more sensitive than FA-F-Test and MSC in detecting responses to complex stimuli because it allows detection of multiple frequencies (HT2_F3) and multiple EEG channels (HT2_MC) simultaneously. This effect was shown in simulation studies for HT2_3F and in EEG data for the HT2_MC algorithm. The spread in detection time across subjects is also lower for the HT2 algorithm, with decision on the presence of an eFFR possible within 5 min.

  11. Sex and age differences in meat composition of Yeso sika deer (Cervus nippon yesoensis) reared for a short period after capture in the wild.

    PubMed

    Hayashida, Maki; Souma, Kousaku; Sugo, Kazuki; Araki, Shin-Ichi; Ishizaka, Fumiaki; Ueda, Masami; Kasai, Takamasa; Masuko, Takayoshi

    2015-02-01

    Yeso sika deer captured in winter around Lake Akan in Hokkaido were reared for 8-10 months at Tokyo University of Agriculture in Abashiri. Six 1-year-old females and males and six 2-year-old or older (adult) females and males were slaughtered and their carcasses were processed. The chemical composition, mineral contents and fatty acid composition of the loin were measured. No marked influence of gender or age was noted in the chemical composition of loin. In the mineral contents, significant differences were noted. The potassium and sulfur contents were lower and the sodium content was higher in adult deer meat (P < 0.05, respectively) and the potassium content was higher in male deer meat (P < 0.05). Arsenic, cadmium or lead were not detected. In the unsaturated fatty acid, a significant interaction was detected (P < 0.05), and it was high in 1-year-old female deer meat and low in 1-year-old male deer meat. Significant gender or age differences were noted only in the mineral contents in the loin of deer reared for a short period after capture. © 2014 Japanese Society of Animal Science.

  12. Circadian rhythm of acute phase proteins under the influence of bright/dim light during the daytime.

    PubMed

    Kanikowska, Dominika; Hyun, Ki-Ja; Tokura, Hiromi; Azama, Takashi; Nishimura, Shinya

    2005-01-01

    We investigated the influence of two different light intensities, dim (100 lx) and bright (5000 lx), during the daytime on the circadian rhythms of selected acute phase proteins of C-reactive protein (CRP), alpha1-acid glycoprotein (AGP), alpha1-antichymotrypsin (ACT), transfferin (TF), alpha2-macroglobulin (alpha2-m), haptoglobin (HP), and ceruloplasmin (CP). Serum samples were collected from 7 healthy volunteers at 4 h intervals during two separate single 24 h spans during which they were exposed to the respective light intensity conditions. A circadian rhythm was detected only in ACT concentration in the bright light condition. The concentration of ACT, a positive acute phase protein (APP), increased (significantly significant differences in the ACT concentration were detected at 14:00 and 22:00 h) and AGP showed a tendency to be higher under the daytime bright compared to dim light conditions. There were no significant differences between the time point means under daytime dim and bright light conditions for alpha2-M, AGP, Tf, Cp, or Hp. The findings suggest that some, but not all, APP may be influenced by the environmental light intensity.

  13. Sensitivity of direct immunofluorescence in oral diseases. Study of 125 cases.

    PubMed

    Sano, Susana Mariela; Quarracino, María Cecilia; Aguas, Silvia Cristina; González, Ernestina Jesús; Harada, Laura; Krupitzki, Hugo; Mordoh, Ana

    2008-05-01

    Direct immunofluorescence (DIF) is widely used for the diagnosis of bullous diseases and other autoimmune pathologies such as oral lichen planus. There is no evidence in the literature on how the following variants influence the detection rate of DIF: intraoral site chosen for the biopsy, perilesional locus or distant site from the clinical lesion, number of biopsies and instrument used. to determine if the following variants influenced the sensitivity (detection rate): intraoral site chosen for the biopsy, perilesional or distant site from the clinical lesion, number of biopsies and instrument used (punch or scalpel). A retrospective study was done at the Cátedra de Patología y Clínica Bucodental II at the Facultad de Odontología, Universidad de Buenos Aires; 136 clinical medical histories were revised for the period March 2000 - March 2005 corresponding to patients with clinical diagnosis of OLP and bullous diseases (vulgar pemphigus, bullous pemphigoid and cicatricial pemphigoid). DIF detection rate was 65.8% in patients with OLP, 66.7% in cicatricial pemphigoid patients, in bullous pemphigoid 55.6%, in pemphigus vulgaris 100%, and in those cases in which certain diagnosis could not be obtained, the DIF positivity rate was 45.5% (Pearson chi(2) (4)= 21.5398 Pr= 0.000). There was no statistically significant difference between the different sites of biopsy (Fisher exact test: 0.825). DIF detection rate in perilesional biopsies was 66.1% and in those distant from the site of clinical lesion was 64.7% (Pearson chi(2) v1)= 0.0073 Pr= 0.932. When the number of biopsies were incremented, DIF detection rate also incremented (Pearson chi(2) = 8.7247 Pr= 0.003). The biopsies taken with punch had a higher detection rate than those taken with scalpel (39.1% versus 71.7%) (Pearson chi(2) = 49.0522 Pr= 0.000). While not statistically significant, the tendency outlined in this study indicates there are intraoral regions in which the detection rate of the DIF technique is higher than others: mouth floor, hard palate, superior labial mucosa, ventral face of tongue. This finding could allow a choice of accessible locations and easy operator manipulation, even in distant places from the clinical lesion. Perilesional biopsies have a detection rate similar to those taken distant from the clinical lesion, and those taken with punch have a higher sensitivity rate than those taken with scalpel (both differences were statistically significant).

  14. Crocodilian perivitelline membrane-bound sperm detection.

    PubMed

    Augustine, Lauren

    2017-05-01

    Advanced reproductive technologies (ART's) are often employed with various taxa to enhance captive breeding programs and maintain genetic diversity. Perivitelline membrane-bound (PVM-bound) sperm detection has previously been demonstrated in avian and chelonian species as a useful technique for breeding management. In the absence of embryotic development within an egg, this technique can detect the presence of sperm trapped on the oocyte membrane confirming breeding, male reproductive status, and pair compatibility. PVM-bound sperm were successfully detected in three clutches of Cuban crocodile (Crocodylus rhombifer) eggs at the Smithsonian's National Zoological Park (NZP) for the first time in any crocodilian species. PVM-bound sperm were detected in fresh and incubated C. rhombifer eggs, as well as eggs that were developing (banded) and those that were not (not banded). The results of this study showed significant differences in average sperm densities per egg between clutches (p = 0.001). Additionally, there was not a significant difference within clutches between eggs that banded and those that did not band (Clutch A, p = 0.505; Clutch B, p = 0.665; Clutch C, p = 0.266). The results of this study demonstrate the necessity to microscopically examine eggs that do not develop (do not band), to determine if sperm is present, which can help animal managers problem solve reproductive shortcomings. PVM-bound sperm detection could be a useful technique in assessing crocodilian breeding programs, as well as have potential uses in studies assessing sperm storage, artificial insemination, and artificial incubation. This article is a U.S. Government work and is in the public domain in the USA.

  15. Comparison between two widely used laboratory methods in BRAF V600 mutation detection in a large cohort of clinical samples of cutaneous melanoma metastases to the lymph nodes.

    PubMed

    Jurkowska, Monika; Gos, Aleksandra; Ptaszyński, Konrad; Michej, Wanda; Tysarowski, Andrzej; Zub, Renata; Siedlecki, Janusz A; Rutkowski, Piotr

    2015-01-01

    The study compares detection rates of oncogenic BRAF mutations in a homogenous group of 236 FFPE cutaneous melanoma lymph node metastases, collected in one cancer center. BRAF mutational status was verified by two independent in-house PCR/Sanger sequencing tests, and the Cobas® 4800 BRAF V600 Mutation Test. The best of two sequencing approaches returned results for 230/236 samples. In 140 (60.9%), the mutation in codon 600 of BRAF was found. 91.4% of all mutated cases (128 samples) represented p.V600E. Both Sanger-based tests gave reproducible results although they differed significantly in the percentage of amplifiable samples: 230/236 to 109/143. Cobas generated results in all 236 cases, mutations changing codon V600 were detected in 144 of them (61.0%), including 5 not amplifiable and 5 negative in the standard sequencing. However, 6 cases positive in sequencing turned out to be negative in Cobas. Both tests provided us with the same BRAF V600 mutational status in 219 out of 230 cases with valid results (95.2%). The total BRAF V600 mutation detection rate didn't differ significantly between the two methodological approaches (60.9% vs. 61.0%). Sequencing was a reproducible method of V600 mutation detection and more powerful to detect mutations other than p.V600E, while Cobas test proved to be less susceptible to the poor DNA quality or investigator's bias. The study underlined an important role of pathologists in quality assurance of molecular diagnostics.

  16. [Effect of Leonurus Heterophyllus Sweet on tissue factor transcription and expression in human umbilical vein endothelial cells in vitro].

    PubMed

    Zheng, Lian; Fang, Chi-hua

    2007-06-01

    To investigate the effect of Leonurus Heterophyllus Sweet, (LHS) on tissue factor (TF) transcription and expression induced by thrombin in human umbilical vein endothelial cells (HUVECs). HUVECs were incubated with different concentrations of LHS and the TF mRNA expression was detected by reverse transcript-polymerase chain reaction (RT-PCR). LHS treatment of HUVECs at different concentrations and for different times resulted in significant differences in TF expression (Plt;0.01). The transcription of TF in LHS-treated cells was significantly different from that of the blank control group (Plt;0.01). LHS can decrease the expression of TF and intervene with TF transcription in HUVECs in vitro.

  17. Comparison of culture and a multiplex probe PCR for identifying Mycoplasma species in bovine milk, semen and swab samples

    PubMed Central

    Parker, Alysia M.; House, John K.; Hazelton, Mark S.; Bosward, Katrina L.; Sheehy, Paul A.

    2017-01-01

    Mycoplasma spp. are a major cause of mastitis, arthritis and pneumonia in cattle, and have been associated with reproductive disorders in cows. While culture is the traditional method of identification the use of PCR has become more common. Several investigators have developed PCR protocols to detect M. bovis in milk, yet few studies have evaluated other sample types or other important Mycoplasma species. Therefore the objective of this study was to develop a multiplex PCR assay to detect M. bovis, M. californicum and M. bovigenitalium, and evaluate its analytical performance against traditional culture of bovine milk, semen and swab samples. The PCR specificity was determined and the limit of detection evaluated in spiked milk, semen and swabs. The PCR was then compared to culture on 474 field samples from individual milk, bulk tank milk (BTM), semen and swab (vaginal, preputial, nose and eye) samples. Specificity analysis produced appropriate amplification for all M. bovis, M. californicum and M. bovigenitalium isolates. Amplification was not seen for any of the other Mollicutes or eubacterial isolates. The limit of detection of the PCR was best in milk, followed by semen and swabs. When all three Mycoplasma species were present in a sample, the limit of detection increased. When comparing culture and PCR, overall there was no significant difference in the proportion of culture and PCR positive samples. Culture could detect significantly more positive swab samples. No significant differences were identified for semen, individual milk or BTM samples. PCR identified five samples with two species present. Culture followed by 16S-23S rRNA sequencing did not enable identification of more than one species. Therefore, the superior method for identification of M. bovis, M. californicum and M. bovigenitalium may be dependent on the sample type being analysed, and whether the identification of multiple target species is required. PMID:28264012

  18. A comparison of DNA extraction procedures for the detection of Mycobacterium ulcerans, the causative agent of Buruli ulcer, in clinical and environmental specimens.

    PubMed

    Durnez, Lies; Stragier, Pieter; Roebben, Karen; Ablordey, Anthony; Leirs, Herwig; Portaels, Françoise

    2009-02-01

    Mycobacterium ulcerans is the causative agent of Buruli ulcer, the third most common mycobacterial disease in humans after tuberculosis and leprosy. Although the disease is associated with aquatic ecosystems, cultivation of the bacillus from the environment is difficult to achieve. Therefore, at the moment, research is based on the detection by PCR of the insertion sequence IS2404 present in M. ulcerans and some closely related mycobacteria. In the present study, we compared four DNA extraction methods for detection of M. ulcerans DNA, namely the one tube cell lysis and DNA extraction procedure (OT), the FastPrep procedure (FP), the modified Boom procedure (MB), and the Maxwell 16 Procedure (M16). The methods were performed on serial dilutions of M. ulcerans, followed by PCR analysis with different PCR targets in M. ulcerans to determine the detection limit (DL) of each method. The purity of the extracted DNA and the time and effort needed were compared as well. All methods were performed on environmental specimens and the two best methods (MB and M16) were tested on clinical specimens for detection of M. ulcerans DNA. When comparing the DLs of the DNA extraction methods, the MB and M16 had a significantly lower DL than the OT and FP. For the different PCR targets, IS2404 showed a significantly lower DL than mlsA, MIRU1, MIRU5 and VNTR6. The FP and M16 were considerably faster than the MB and OT, while the purity of the DNA extracted with the MB was significantly higher than the DNA extracted with the other methods. The MB performed best on the environmental and clinical specimens. This comparative study shows that the modified Boom procedure, although lengthy, provides a better method of DNA extraction than the other methods tested for detection and identification of M. ulcerans in both clinical and environmental specimens.

  19. Illumination Invariant Change Detection (iicd): from Earth to Mars

    NASA Astrophysics Data System (ADS)

    Wan, X.; Liu, J.; Qin, M.; Li, S. Y.

    2018-04-01

    Multi-temporal Earth Observation and Mars orbital imagery data with frequent repeat coverage provide great capability for planetary surface change detection. When comparing two images taken at different times of day or in different seasons for change detection, the variation of topographic shades and shadows caused by the change of sunlight angle can be so significant that it overwhelms the real object and environmental changes, making automatic detection unreliable. An effective change detection algorithm therefore has to be robust to the illumination variation. This paper presents our research on developing and testing an Illumination Invariant Change Detection (IICD) method based on the robustness of phase correlation (PC) to the variation of solar illumination for image matching. The IICD is based on two key functions: i) initial change detection based on a saliency map derived from pixel-wise dense PC matching and ii) change quantization which combines change type identification, motion estimation and precise appearance change identification. Experiment using multi-temporal Landsat 7 ETM+ satellite images, Rapid eye satellite images and Mars HiRiSE images demonstrate that our frequency based image matching method can reach sub-pixel accuracy and thus the proposed IICD method can effectively detect and precisely segment large scale change such as landslide as well as small object change such as Mars rover, under daily and seasonal sunlight changes.

  20. Detection of copy number variations in epilepsy using exome data.

    PubMed

    Tsuchida, N; Nakashima, M; Kato, M; Heyman, E; Inui, T; Haginoya, K; Watanabe, S; Chiyonobu, T; Morimoto, M; Ohta, M; Kumakura, A; Kubota, M; Kumagai, Y; Hamano, S-I; Lourenco, C M; Yahaya, N A; Ch'ng, G-S; Ngu, L-H; Fattal-Valevski, A; Weisz Hubshman, M; Orenstein, N; Marom, D; Cohen, L; Goldberg-Stern, H; Uchiyama, Y; Imagawa, E; Mizuguchi, T; Takata, A; Miyake, N; Nakajima, H; Saitsu, H; Miyatake, S; Matsumoto, N

    2018-03-01

    Epilepsies are common neurological disorders and genetic factors contribute to their pathogenesis. Copy number variations (CNVs) are increasingly recognized as an important etiology of many human diseases including epilepsy. Whole-exome sequencing (WES) is becoming a standard tool for detecting pathogenic mutations and has recently been applied to detecting CNVs. Here, we analyzed 294 families with epilepsy using WES, and focused on 168 families with no causative single nucleotide variants in known epilepsy-associated genes to further validate CNVs using 2 different CNV detection tools using WES data. We confirmed 18 pathogenic CNVs, and 2 deletions and 2 duplications at chr15q11.2 of clinically unknown significance. Of note, we were able to identify small CNVs less than 10 kb in size, which might be difficult to detect by conventional microarray. We revealed 2 cases with pathogenic CNVs that one of the 2 CNV detection tools failed to find, suggesting that using different CNV tools is recommended to increase diagnostic yield. Considering a relatively high discovery rate of CNVs (18 out of 168 families, 10.7%) and successful detection of CNV with <10 kb in size, CNV detection by WES may be able to surrogate, or at least complement, conventional microarray analysis. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Top